Bolstering the Nasoseptal Flap Using Sphenoid Sinus Fat Packing: A Technical Case Report.
Abou-Al-Shaar, Hussam; Zaidi, Hasan A; Cote, David J; Laws, Edward R
2017-03-01
Resection of extensive skull base lesions often necessitates relatively large dural openings and arachnoid, resulting in skull base defects with the potential for a postoperative cerebrospinal fluid leak. A nasoseptal flap (NSF) is a vascularized graft that has greatly diminished the incidence of cerebrospinal fluid leak. Annealing of flaps against the ventral skull base can be tenuous within the first few days after surgery. We report the use of sphenoid sinus fat packing as a buttress to support the nasoseptal flap during skull base reconstruction. A 37-year-old man presented with pan-hypopituitarism, bitemporal hemianopsia, and imaging consistent with a craniopharyngioma. He underwent an endoscopic endonasal approach with resection of the planum and tuberculum sphenoidale for resection of this mass. An NSF was harvested, and a combination of suprasellar fat packing, tensor fasciae lata graft, and Porex plate along with the flap were used to reconstruct the skull base. Postoperatively, he precipitously experienced copious rhinorrhea necessitating surgical re-exploration. A redundant segment of the NSF had retracted into the sphenoid sinus, and was no longer supported against the ventral skull base. We repositioned the NSF and used sphenoid sinus fat packing to help support the graft against the ventral skull base. A postoperative computed tomographic scan demonstrated a clear delineation between the vascularized graft and the fat packing, confirming proper positioning of the flap. Sphenoid sinus fat packing can be an important technical adjunct in bolstering the nasoseptal flap against the ventral skull base in the tenuous early perioperative period. Copyright © 2016 Elsevier Inc. All rights reserved.
Dobbs, Nathan B; Latifi, Hamid R
2013-08-01
We report a case of a 57-year-old female patient with right breast invasive ductal carcinoma. Bilateral mastectomy and TRAM flap reconstructions were performed. Postoperatively, a palpable focus was identified within the left breast. PET/CT showed hypermetabolism throughout the reconstructed left breast, correlating with mixed fat attenuation and inflammatory soft tissue. MRI showed extensive fat necrosis/oil cyst formation in the left breast. As a TRAM flap reconstruction with fat-rich tissue can be damaged intraoperatively due to surgical manipulation, abnormal FDG uptake in this setting is more likely related to fat necrosis than recurrent tumor.
Golbin, Denis A.; Lasunin, Nikolay V.; Cherekaev, Vasily A.; Polev, Georgiy A.
2016-01-01
Objectives To evaluate the efficacy and safety of using a buccal fat pad for endoscopic skull base defect reconstruction. Design Descriptive anatomical study with an illustrative case presentation. Setting Anatomical study was performed on 12 fresh human cadaver specimens with injected arteries (24 sides). Internal carotid artery was exposed in the coronal plane via the endoscopic transpterygoid approach. The pedicled buccal fat pad was used for reconstruction. Participants: 12 human cadaver head specimens; one patient operated using the proposed technique. Main outcome measures: Proximity of the buccal fat pad flap to the defect, compliance of the flap, comfort and safety of harvesting procedure, and compatibility with the Hadad–Bassagasteguy nasoseptal flap. Results: Harvesting procedure was performed using anterior transmaxillary corridor. The pedicled buccal fat pad flap can be used to pack the sphenoid sinus or cover the internal carotid artery from cavernous to upper parapharyngeal segment. Conclusion The buccal fat pad can be safely harvested through the same approach without external incisions and is compliant enough to conform to the skull base defect. The proposed pedicled flap can replace free abdominal fat in central skull base reconstruction. The volume of the buccal fat pad allows obliteration of the sphenoid sinus or upper parapharyngeal space. PMID:28180047
Streit, L; Dražan, L; Schneiderová, M; Kubek, T; Sin, P; Veselý, K; Coufal, O; Veselý, J
2017-01-01
The latissimus dorsi flap is a reliable and one of the most commonly used methods of both immediate and delayed breast reconstruction. Its disadvantage is the limited volume of transferred tissue. The authors present their experience with the use of extended latissimus dorsi flap associated with immediate fat grafting into the pectoralis and latissimus dorsi muscles for secondary breast reconstruction. From 2013 to 2016, 14 patients underwent secondary unilateral total breast reconstruction with extended latissimus dorsi flap associated with primary fat grafting into the pectoralis major and latissimus dorsi muscles. Fat was injected under visual control between muscle fibers. Fat injected into the pectoralis muscle formed an apparent bulging - autoprosthesis. Mean patient age was 48.2 years (range, 34 to 64 years). Mean injected fat volume was 86.4 ml (range, 50 to 160 ml) and majority of this volume was injected into the pectoralis muscle. All flaps healed uneventfully and no fat grafting-related complications were observed. The most common complication was donor site seroma, which occurred in 57.1%. Results of postoperative ultrasound examination were evaluated. Incidence and the size of oil cysts and fat necroses were significantly lower in muscular layer in comparison with the subcutaneous layer of the reconstructed breast. Immediate fat transfer into the pectoralis and latissimus dorsi muscle increases the breast volume during the reconstruction with extended latissimus dorsi flap avoiding implant-related complications when abdominal tissue is not available. Pectoralis and latissimus dorsi muscles were shown as reliable and safe recipients for fat grafting.
Demiri, Efterpi C; Dionyssiou, Dimitrios D; Tsimponis, Antonios; Goula, Christina-Olga; Pavlidis, Leonidas C; Spyropoulou, Georgia-Alexandra
2018-06-01
Although free abdominal flaps constitute the gold standard in post-radiation delayed breast reconstruction, latissimus dorsi-based methods offer alternative reconstructive options. This retrospective study aims to compare outcomes of delayed breast reconstruction using the fat-augmented latissimus dorsi (FALD) autologous reconstruction and the latissimus dorsi-plus-implant reconstruction in irradiated women. We reviewed the files of 47 post-mastectomy irradiated patients (aged 29-73 years), who underwent delayed latissimus dorsi-based breast reconstruction between 2010 and 2016. Twenty-three patients (Group A) had an extended FALD flap and twenty-four patients (Group B) an implant-based latissimus dorsi reconstruction. Patients' age, BMI, pregnancies, volume of injected fat, implant size, postoperative complications, and secondary surgical procedures were recorded and analyzed. Age, BMI, pregnancies, and donor-site complications were similar in both groups (p > 0.05). Mean fat volume injected initially was 254 cc (ranged 130-380 cc/session); mean implant volume was 323 cc (ranged 225-420 cc). Breast complications were significantly fewer in Group A (one wound dehiscence, two oily cysts) compared to Group B (three cases with wound dehiscence, two extrusions, thirteen severe capsular contractions). Non-statistically significant difference was documented for secondary procedures between groups; although the mean number of additional surgeries/patient was higher in Group A, they referred to secondary lipofilling, whereas in Group B they were revision surgeries for complications. The FALD flap constitutes an alternative method for delayed autologous reconstruction after post-mastectomy irradiation, avoiding implant-related complications. Although additional fat graft sessions might be required, it provides an ideal autogenous reconstructive option for thin nulliparous women, with a small opposite breast and adequate fat donor sites. This journal requires that
Li, Xiu-Qi; Wang, Jia-Qi
2018-05-31
Forehead aging is characterized by wrinkles, loss of skin elasticity, brow ptosis, and soft-tissue atrophy. For patients with prominent rhytids and marked brow ptosis, forehead lift is still the most effective treatment with a persisting result. In order to eliminate the glabellar wrinkles, forehead lift usually requires the removal of the corrugator supercilii muscle and procerus, which can lead to glabellar flattening or depression. Instead of muscle removal, the corrugator supercilii muscle, procerus, and the underlying galea were dissected as a pedicled glabellar flap. Then reversed periosteum or dermal fat graft was used to cover the glabellar flap to restore the glabellar volume. From January 2005 to November 2014, a total of 164 coronal and 42 trichophytic forehead lifts were performed. Reversed periosteum was used to cover the glabellar flap in 191 patients while dermal fat graft was applied in 15 patients with a follow-up period ranging from 6 months to 10 years. There was no irregularity or depression in the glabellar region in the group of reversed periosteal flap. The take of dermal fat graft placed over the glabellar flap was minimal. Complications from surgical procedures occurred in 2.91% of the patients. There was 1 asymmetry, 4 patients with higher than desired frontal hairline for implantation of autologous follicular units, and 1 patient with scar hyperplasia. There was no hematoma or nerve injury, no permanent numbness, and no alopecia. The techniques are simple and effective to eliminate the glabellar wrinkles and maintain or restore the glabellar volume.
Suprascarpal fat pad thickness may predict venous drainage patterns in abdominal wall flaps.
Bast, John; Pitcher, Austin A; Small, Kevin; Otterburn, David M
2016-02-01
Abdominal wall flaps are routinely used in reconstructive procedures. In some patients inadequate venous drainage from the deep vein may cause fat necrosis or flap failure. Occasionally the superficial inferior epigastric vessels (SIEV) are of sufficient size to allow for microvascular revascularization. This study looked at the ratio of the sub- and suprascarpal fat layers, the number of deep system perforators, and SIEV diameter to determine any correlation of the fat topography and SIEV. 50 abdominal/pelvic CT angiograms (100 hemiabdomens) were examined in women aged 34-70 years for number of perforators, SIEV diameter, and fat pad thickness above and below Scarpa's fascia. Data was analyzed using multivariate model. The average suprascarpal and subscarpal layers were 18.6 ± 11.5 mm and 6.2 ± 7.2 mm thick, respectively. The average SIEV diameter was 2.06 ± 0.81 mm and the average number of perforators was 2.09 ± 1.03 per hemiabdomen. Hemiabdomens with suprascarpal thickness>23 mm had greater SIEV diameter [2.69 mm vs. 1.8 mm (P < 0.0001)] The fat layer thickness did not correlate with the number of perforators. Neither subscarpal fat thickness nor suprascarpal-to-subscarpal fat layer thickness correlated significantly with SIEV caliber or number of perforators in multivariate model. Suprascarpal fat pad thicker than 23 mm had larger SIEVs irrespective of the number of deep system perforators. This may indicate a cohort of patients at risk of venous congestion from poor venous drainage if only the deep system is revascularized. We recommend harvesting the SIEV in patients with suprascarpal fat pad >23 mm to aid in superficial drainage. © 2015 Wiley Periodicals, Inc.
Liang, Zhi-Jie; Huang, Min-Hong; Peng, Qi-Liu; Zou, Dong-Hua; Gu, Rong-He; Xu, Fang-Tian; Gao, Hui; Chen, Zhen-Dong; Chi, Guang-Yi; Wei, Zhong-Heng; Chen, Li; Li, Hong-Mian
2017-01-01
Fat flap transplantation is frequently performed in patients suffering from soft tissue defects resulting from disease or trauma. This study explored the feasibility of constructing vascularized fat flaps using rabbit adipose-derived stem cells (rASCs) and collagen scaffolds in a rabbit model. We evaluated rASCs proliferation, paracrine function, adipogenesis, vascularization, and CD54 expression, with or without HIF-1α transfection in vitro and in vivo. We observed that adipogenic differentiation potential was greater in rASCs with high CD54 expression (CD54+rASCs) than in those with low expression (CD54–rASCs), both in vitro and in vivo. HIF-1α overexpression not only augmented this effect, but also enhanced cell proliferation and paracrine function in vitro. We also demonstrated that HIF-1α-transfected CD54+rASCs showed enhanced paracrine function and adipogenic capacity, and that paracrine function increases expression of angiogenesis-related markers. Thus, CD54+rASCs overexpressing HIF-1α enhanced large volume vascularized fat flap regeneration in rabbits, suggesting CD54 may be an ideal candidate marker for ASCs adipogenic differentiation. PMID:28423354
Pedicled fat flap to increase lateral fullness in upper blepharoplasty.
Sozer, Sadri O; Agullo, Francisco J; Palladino, Humberto; Payne, Phileemon E; Banerji, Soumo
2010-03-01
The eyelid of a young person can be distinguished by the lateral fullness of the upper eyelid. With aging, lateral fullness decreases. Volume restoration in the periorbital area has been previously addressed by fat draping and grafting. More recently, techniques for regaining lateral fullness of the upper eyelid have focused on fat grafting, although effective graft take, reabsorption, and irregularities have been a concern. To address these issues, the concept of pedicled fat draping in the upper eyelid was explored. In a retrospective study from June 2006 to August 2008, 31 patients underwent upper blepharoplasty with augmentation of the lateral fullness with a pedicled fat flap from the central fat pad. The fat from the central compartment was elevated, dissected, and then transposed to the lateral upper eyelid below the orbicularis muscle. All patients were women ranging in age from 43 to 68 years. Pre- and postoperative picture comparison demonstrated a more youthful appearance with increased lateral fullness of the upper eyelids. There were no cases of fat necrosis encountered. Increased volume remained stable over an average of one-year follow-up. No complications were recorded. Transposing a pedicled fat pad from the central compartment laterally has proven to be an effective technique for achieving predictable upper lateral eyelid fullness and thus achieving a long-lasting, more youthful appearance.
Carruthers, Katherine H; During, Matthew J; Muravlev, Alexander; Wang, Chuansong; Kocak, Ergun
2013-06-01
The combination of gene therapy and plastic surgery may have the potential to improve the specificity that is needed to achieve clinically applicable treatment regimens. Our goal was to develop a method for gene modification that would yield sustainable production of gene products but would be less time consuming than existing protocols. An adenoassociated virus was used to deliver gene products to pectoralis muscle flaps. Gene modification was accomplished via either direct injection or novel fat grafting techniques. The production of gene product was observable by both in vivo imaging and immunohistochemical staining. Gene products were not detected in tissues that were not in contact with the fat grafts that were incubated with the viral vector, indicating that the transduction stayed local to the flap. Using novel recombinant adenoassociated virus vectors, we have developed a method for gene delivery that is highly efficient and applicable to muscle flaps.
Markey, Jeff; Benet, Arnau; El-Sayed, Ivan H
2015-10-01
Extirpation via expanded endonasal approaches (EEA) to the skull base can result in defects requiring vascularized rotational flap reconstruction. The buccal fat pad (BFP) is a vascularized graft described in open skull base resections, but its harvest and adequacy of vascular supply have not been examined for use with EEA. A transfacial cadaveric dissection was carried forth in a latex-injected specimen to characterize the BFP blood supply. Then a cadaveric dissection series was performed involving the endoscopic harvest and rotation of 10 buccal fat pads in five cadaveric specimens to assess defect coverage. An endoscopic medial maxillectomy combined with an anterior maxillotomy was performed prior to endoscopic harvest in cadaveric specimens. The BFP was rotated to assess its capability to reconstruct seven possible ventral skull base defects. Finally, the BFP vascular anatomy was further characterized following harvest and transposition. The BFP reconstructed defects at the greater sphenoid wing, inferior and superior clivus, sella, planum, and bilateral ethmoids in all cadaveric specimens. In some cases it covered two sites concurrently. The BFP pedicled rotational flap is a potential alternate flap following EEA in select cases. NA © 2015 The American Laryngological, Rhinological and Otological Society, Inc.
Lower Extremity Free Flaps for Breast Reconstruction.
Dayan, Joseph H; Allen, Robert J
2017-11-01
Thigh-based flaps are typically a secondary option for breast reconstruction because of concerns regarding limited tissue volume and donor-site morbidity. In recent years, there have been a number of new techniques and insights that have resulted in greater flexibility and improved outcomes. This article reviews lessons learned from a large collective experience using the following 4 flaps: transverse upper gracilis also known as transverse myocutaneous gracilis, diagonal upper gracilis, profunda artery perforator, and lateral thigh perforator flaps. Flap selection considerations include the patient's fat distribution and skin laxity, perforator anatomy, and scar location. Pearls to minimize donor-site morbidity include avoiding major lymphatic collectors in the femoral triangle and along the greater saphenous vein and respecting the limits of flap dimension to reduce wound healing complications and distal ischemia. Limited flap volume may be addressed with stacking another flap from the contralateral thigh or primary fat grafting as opposed to overaggressive flap harvest from a single thigh. A detailed review of the benefits and disadvantages of each flap and strategies to improve results is discussed. With careful planning and selection, thigh-based flaps can provide a reliable option patients desiring autologous breast reconstruction.
Four-flap Breast Reconstruction: Bilateral Stacked DIEP and PAP Flaps
Mayo, James L.; Allen, Robert J.
2015-01-01
Background: In cases of bilateral breast reconstruction when the deep inferior epigastric perforator (DIEP) free flap alone does not provide sufficient volume for body-specific reconstruction, stacking each DIEP flap with a second free flap will deliver added volume and maintain a purely autologous reconstruction. Stacking the profunda artery perforator (PAP) flap with the DIEP flap offers favorable aesthetics and ideal operative efficiency. We present the indications, technique, and outcomes of our experience with 4-flap breast reconstruction using stacked DIEP/PAP flaps. Methods: The authors performed 4-flap DIEP/PAP breast reconstruction in 20 patients who required bilateral reconstruction without adequate single donor flap volume. The timing of reconstruction, average mastectomy/flap weights, and operative time are reported. Complications reviewed include fat necrosis, dehiscence, hematoma, seroma, mastectomy flap necrosis, and flap loss. Results: Twenty patients underwent 4-flap DIEP/PAP breast reconstruction. Surgical time averaged 7 hours and 20 minutes. The primary recipient vessels were the antegrade and retrograde internal mammary vessels. No flap losses occurred. Complications included 1 hematoma, 1 incidence of arterial and venous thrombosis successfully treated with anastomotic revision, 1 incidence of thigh donor site dehiscence, and 3 episodes of minor mastectomy skin flap necrosis. Conclusions: Four-flap breast reconstruction is a favorable autologous reconstructive option for patients requiring bilateral reconstruction without adequate single donor flap volume. Stacking DIEP/PAP flaps as described is both safe and efficient. Furthermore, this combination provides superior aesthetics mirroring the natural geometry of the breast. Bilateral stacked DIEP/PAP flaps represent our first choice for breast reconstruction in this patient population. PMID:26090273
Latissimus dorsi flap for total autologous immediate breast reconstruction without implants.
Santanelli di Pompeo, Fabio; Laporta, Rosaria; Sorotos, Michail; Pagnoni, Marco; Falesiedi, Federica; Longo, Benedetto
2014-12-01
The latissimus dorsi flap provides suitable recipient tissue for fat transfer, with a good blood supply and a reasonable volume of host tissue to inject into. The authors present their experience with use of the pedicled latissimus dorsi flap for fat grafting in total autologous immediate breast reconstruction without implants. From 2010 to 2013, 23 patients underwent breast reconstruction with primary fat augmented latissimus dorsi flaps (21 unilateral procedures and two bilateral procedures). Mean patient age was 52.3 years (range, 39 to 68 years); mean body mass index was 24.77 kg/m2 (range, 21.5 to 28.7 kg/m2). Fat was harvested using the Coleman technique with 10-ml syringes and injected into the adipose layer and muscle fascia of the latissimus dorsi flap skin paddle with 1-ml syringes. The mean size of the harvested skin paddle was 19.7 × 11.04 cm (range, 18 × 10 cm to 21 × 12 cm). Mean operative time was 2.62 hours (range, 2.10 to 3.20 hours) and 4.12 hours (range, 4.10 to 4.15 hours) for unilateral and bilateral reconstructions, respectively. Mean harvested fat volume was 126 ml (range, 90 to 180 ml), and mean injected fat volume was 101 ml (range, 60 to 150 ml). All flaps healed uneventfully, no seroma occurred at the flap donor-site, and no fat grafting-related complications were observed. To the best of the authors' knowledge, this is the first report in which fat transfer was used to achieve immediate latissimus dorsi flap volume augmentation as an alternative for total autologous reconstruction, avoiding implant-related complications.
Casey, William J; Connolly, Katharine A; Nanda, Alisha; Rebecca, Alanna M; Perdikis, Galen; Smith, Anthony A
2015-03-01
The reliability of deep inferior epigastric artery perforator (DIEP) flap reconstruction following abdominal liposuction is controversial. The authors' early cases were technically successful; however, they experienced high partial flap loss and fat necrosis rates. The authors sought to compare DIEP flap outcomes in the setting of prior liposuction after the use of intraoperative indocyanine green angiography compared to when flaps were assessed on clinical grounds alone. A retrospective review of a consecutive series of DIEP flaps following liposuction at a single institution was performed, comparing those evaluated on clinical grounds alone and those in which indocyanine green angiography was used intraoperatively. Outcomes measured included anastomotic complications, total flap loss, partial flap loss, fat necrosis, and postoperative abdominal wounds. Thirteen DIEP flaps following prior liposuction were performed on 11 patients from July of 2003 through January of 2014. All patients had preoperative imaging with duplex ultrasound or computed tomographic angiography to analyze perforator suitability before surgical exploration. Seven flaps were evaluated intraoperatively on clinical grounds alone. Six flaps were assessed and modified based on indocyanine green angiography. All flaps were successful; however, partial flap loss and fat necrosis rates dropped from 71.4 percent to 0 percent when indocyanine green angiography was used intraoperatively (p = 0.02). Indocyanine green angiography is an excellent vascular imaging modality for intraoperative use to assess flap perfusion, and improves outcomes in DIEP flaps when harvested after prior abdominal suction lipectomy.
Schoeller, Thomas; Huemer, Georg M; Wechselberger, Gottfried
2008-07-01
The transverse musculocutaneous gracilis (TMG) flap has received little attention in the literature as a valuable alternative source of donor tissue in the setting of breast reconstruction. The authors give an in-depth review of their experience with breast reconstruction using the TMG flap. A retrospective review of 111 patients treated with a TMG flap for breast reconstruction in an immediate or a delayed setting between August of 2002 and July of 2007 was undertaken. Of these, 26 patients underwent bilateral reconstruction and 68 underwent unilateral reconstruction, and 17 patients underwent reconstruction unilaterally with a double TMG flap. Patient age ranged between 24 and 65 years (mean, 37 years). Twelve patients had to be taken back to the operating room because of flap-related problems and nine patients underwent successful revision microsurgically, resulting in three complete flap losses in a series of 111 patients with 154 transplanted TMG flaps. Partial flap loss was encountered in two patients, whereas fat tissue necrosis was managed conservatively in six patients. Donor-site morbidity was an advantage of this flap, with a concealed scar and minimal contour irregularities of the thigh, even in unilateral harvest. Complications included delayed wound healing (n = 10), hematoma (n = 5), and transient sensory deficit over the posterior thigh (n = 49). The TMG flap is more than an alternative to the deep inferior epigastric perforator (DIEP) flap in microsurgical breast reconstruction in selected patients. In certain indications, such as bilateral reconstructions, it possibly surpasses the DIEP flap because of a better concealed donor scar and easier harvest.
Use of various free flaps in progressive hemifacial atrophy.
Baek, Rongmin; Heo, Chanyeong; Kim, Baek-kyu
2011-11-01
Romberg disease is an uncommon condition manifested by progressive hemifacial atrophy of the skin, soft tissue, and bone. Facial asymmetry with soft tissue deficiency in Romberg disease causes a significant disability affecting the social life and can bring about many psychological problems. The aim of surgical treatment is cosmetic amelioration of the defect. Several conventional reconstructive procedures have been used for correcting facial asymmetry. They include fat injections, dermal fat grafts, filler injections, cartilage and bone grafts, and pedicled and free flaps. We report our experiences with 11 patients involving 11 free flaps with a minimum 1-year follow-up. All patients were classified as having moderate to severe atrophy. The average age at disease onset was 4.5 years; the average duration of atrophy was 5.2 years. No patients were operated on with a quiescent interval of less than 1 year. The average age at operation was 20.1 years, ranging from 10 to 55 years. Reconstruction was performed using 4 groin dermofat free flaps, 4 latissimus dorsi muscle free flaps, and 3 other perforator flaps. To achieve the finest symmetrical and aesthetic results, several ancillary procedures were performed in 4 patients. These procedures included Le Fort I leveling osteotomy, sagittal split ramus osteotomy, reduction malarplasty and angle plasty, rib and calvarial bone graft, correction of alopecia, and additional fat graft. All patients were satisfied with the results. We believe that a free flap transfer is the requisite treatment modality for severe degree of facial asymmetry in Romberg disease.
Primary Fat Grafting to the Pectoralis Muscle during Latissimus Dorsi Breast Reconstruction.
Niddam, Jeremy; Vidal, Luciano; Hersant, Barbara; Meningaud, Jean Paul
2016-11-01
Latissimus dorsi flap is one of the best options for immediate and delayed breast reconstruction. However, this technique is limited by the tissue volume provided by the flap. To improve breast volume while reducing complications, fat grafting is now very often used in addition to latissimus dorsi flap. To the best of our knowledge, fat grafting was always performed as a second-line surgery, at least a few months after the flap procedure. We aimed to report our experience with an associated breast reconstruction technique combining musculocutaneous latissimus dorsi flap with intrapectoral lipofilling for totally autologous breast reconstruction. Between September 2014 and January 2015, 20 patients underwent this technique for unilateral autologous breast reconstruction (14 delayed and 6 immediate breast reconstructions). A mean harvested fat volume of 278 ml (range: 190-350 ml) and a mean injected fat volume of 228 ml (range: 170-280 ml) were used. None of the patients experienced complications, such as flap necrosis, breast skin necrosis, hematomas, or infection. One of the patients developed a seroma, which was treated with 3 drainage punctions. Only 2 patients underwent delayed fat grafting procedure. Totally autologous breast reconstruction combining latissimus dorsi flap and intrapectoral fat grafting in the same procedure is a new technique allowing increased breast volume in a single surgery.
Primary Fat Grafting to the Pectoralis Muscle during Latissimus Dorsi Breast Reconstruction
Vidal, Luciano; Hersant, Barbara; Meningaud, Jean Paul
2016-01-01
Background: Latissimus dorsi flap is one of the best options for immediate and delayed breast reconstruction. However, this technique is limited by the tissue volume provided by the flap. To improve breast volume while reducing complications, fat grafting is now very often used in addition to latissimus dorsi flap. To the best of our knowledge, fat grafting was always performed as a second-line surgery, at least a few months after the flap procedure. We aimed to report our experience with an associated breast reconstruction technique combining musculocutaneous latissimus dorsi flap with intrapectoral lipofilling for totally autologous breast reconstruction. Methods: Between September 2014 and January 2015, 20 patients underwent this technique for unilateral autologous breast reconstruction (14 delayed and 6 immediate breast reconstructions). A mean harvested fat volume of 278 ml (range: 190–350 ml) and a mean injected fat volume of 228 ml (range: 170–280 ml) were used. Results: None of the patients experienced complications, such as flap necrosis, breast skin necrosis, hematomas, or infection. One of the patients developed a seroma, which was treated with 3 drainage punctions. Only 2 patients underwent delayed fat grafting procedure. Conclusion: Totally autologous breast reconstruction combining latissimus dorsi flap and intrapectoral fat grafting in the same procedure is a new technique allowing increased breast volume in a single surgery. PMID:27975006
Zhang, Qixu; Johnson, Joshua A; Dunne, Lina W; Chen, Youbai; Iyyanki, Tejaswi; Wu, Yewen; Chang, Edward I; Branch-Brooks, Cynthia D; Robb, Geoffrey L; Butler, Charles E
2016-04-15
vascular reanastomosis in the recipient site, the engineered products successful regenerated large-scale fat tissue in vivo. This approach may provide a translatable platform for composite soft tissue free flap engineering for microsurgical reconstruction. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Keystone-designed buried de-epithelialized flap
Kim, Hoon; Ryu, Wan Cheol; Yoon, Chi Sun; Kim, Kyu Nam
2017-01-01
Abstract Effective obliteration of dead space after reconstructive surgery facilitates a good cosmetic outcome and prevention of delayed wound healing and recurrent infection. We evaluated the efficacy of a keystone-designed buried de-epithelialized (KBD) flap for the obliteration of small to moderately sized surgical dead spaces. We reviewed the medical records of patients who received a KBD flap following removal of a mass or debridement of necrotic tissue from September 2015 to February 2016. The diagnosis, site, dead space dimensions, flap width, drain data, complications, and follow-up duration were recorded. Twenty-eight KBD flaps were evaluated, including 9 cases of fat necrosis, 7 cases of epidermal cyst, and 12 cases of lipoma. Dead space dimensions ranged from 2 × 1.5 × 1 cm to 10 × 5 × 3 cm, with a mean depth of 2.01 cm. Flap sizes ranged from 2.5 × 1 cm to 11 × 3 cm, with a mean flap width of 2.01 cm. No postoperative complications, such as seroma or hematoma, occurred. The cosmetic results were favorable, and all patients were satisfied with their final outcomes. The KBD flap is useful for the obliteration of small to moderately sized surgical dead spaces both spatially and physiologically and shows excellent cosmetic outcomes. PMID:28538418
[Pedicled versus free TRAM flap for breast reconstruction].
Galla, T J; Lukas, B; Feller, A M
1999-03-01
In breast reconstruction, the free TRAM-flap offers many advantages over the pedicled TRAM-flap. Due to its superior perfusion, the free flap rarely develops necrosis. Shaping of the flap is easier due to the lack of the thick muscle pedicle. Because the rectus muscle is spared, there is minimal donor site morbidity. However, the necessary microvascular anastomoses reduced the acceptance of the free TRAM-flap. During a 13-months period, 51 breast reconstructions were performed in 41 patients, 31 unilateral and ten bilateral. 45 flaps served for delayed reconstruction and six flaps for immediate reconstruction. The operations were performed by two teams working simultaneously. The average operating time was 3.9 hours for unilateral and 6.9 hours for bilateral delayed reconstruction. For immediate reconstruction, 6.2 and 6.3 hours were required for uni- and bilateral procedures, respectively. In 38 flaps, the thoracodorsal vessels served as recipient vessels; 13 flaps were anastomosed to the internal mammary artery and vein. Postoperative complications were observed in 13 patients. Three vessel anastomoses had to be revised. In one flap, a partial necrosis occurred; in two flaps hematoma evacuation was necessary. Two patients suffered from fat necroses at the abdomen and one umbilicus was lost. Skin irritations and seromas at the abdomen occurred in five patients. Pulmonary embolism was diagnosed in one patient three weeks postoperatively. Abdominal hernias or bulging in the epigastric area were not observed up to 15 months after reconstruction. These results reveal a low complication rate for breast reconstruction with the free TRAM-flap. The advantages of this technique as compared to the pedicled technique are discussed.
Bodin, Frédéric; Dissaux, Caroline; Dupret-Bories, Agnes; Schohn, Thomas; Fiquet, Caroline; Bruant-Rodier, Catherine
2016-01-01
The transverse musculocutaneous gracilis (TMG) flap has become a common solution for breast reconstruction. However, the safe skin paddle limits are not yet understood. In this study, we attempted to address this issue based on our experiences with inferior and posterior skin paddle extension. Forty-four breast reconstructions with TMG flaps performed between November 2010 and January 2014 were analyzed retrospectively. For the first 20 cases, the flap skin paddle was extended 3 cm posteriorly to the middle thigh (group 1). For the next 20 flaps (group 2), the posterior tip was limited to this line, whereas more fat was recruited inferiorly. In the four cases of group 3, the skin flap was extended posteriorly with a second vascular pedicle from the profunda artery perforator (PAP) flap. The weights and the dimensions of the flaps, operating durations, and postoperative complications of the entire series were analyzed. Groups 1 and 2 were statistically compared. Flap complications were statistically more frequent in group 1 compared with group 2 (45 vs. 0%, P = 0.0012); 40% posterior flap tip necrosis was observed in group 1. Conversely, donor site complications were statistically more frequent in group 2 than in group 1 (40 vs. 5%, P = 0.019) with 35% inner thigh dehiscence. In the TMG with extended PAP flap group, the operating duration was 77 min longer compared with the rest of the series with no donor site complications. In one case, limited necrosis occurred at the anterior skin tip. Harvesting the posterior portion of the TMG up to the middle of the posterior thigh may lead to partial flap necrosis. Extending subcutaneous fat removal under the inferior skin incision may increase the risk of donor site complications. Adding a second vascular pedicle from the PAP flap may improve posterior TMG tip perfusion at the expense of a longer operation. © 2015 Wiley Periodicals, Inc.
[APPLICATION VALUE OF INDOCYANINE GREEN ANGIOGRAPHY IN FLAP RECONSTRUCTIVE SURGERY].
Yang, Kai; Mu, Lan; Liu, Yan; Peng, Zhe; Li, Guangxue
2015-09-01
To investigate the utility of indocyanine green angiography in flap reconstructive surgery and possibility of decrease the complications. Indocyanine green angiography was performed on 14 patients undergoing flap reconstructive surgery between February and December 2014 to evaluate the blood perfusion of the flap and to adjust the operation plan. Of 14 cases, 2 were male and 12 were female, aged 23-58 years (mean, 35.5 years); 11 flaps were used for breast reconstruction [including 3 free deep inferior epigastric antery perforator (DIEP) flaps, 4 pedicled transverse rectus abdominis myocutaneous flaps (TRAM), 2 pedicled TRAM and free TRAM, and 2 pedicled latissimus dorsi myocutaneous flaps and prosthesis], 1 pedicled latissimus dorsi myocutaneous flap for repairing chest wall defect, 1 pedicled profunda artery perforator (PAP) flap for upper leg defect, and 1 pedicled descending genicular artery perforator flap for knee defect. The size of the flaps ranged from 9 cm x 6 cm to 26 cm x 12 cm. A total of 32 indocyanine green angiography were performed. There was no adverse reactions to the infusion of indocyanine green. The surgery management was adjusted according to results of indocyanine green angiography findings in 5 of 14 cases. The distal part of flap were discarded because of poor perfusion in 3 cases (1 DIEP flap, 1 TRAM, and 1 PAP flap) and the other 2 cases (pedicled TRAM) needed additional free anastomosis to ensure sufficient blood supply (pedicled TRAM and free TRAM); the other flaps were harvested according to preoperative plan and repaired defect successfully. The mean follow-up was 5 months (range, 1-9 months). The other flaps survived without infection or fat necrosis except 1 PAP flap with distal necrosis. Intraoperative indocyanine green angiography can provide real-time information of flap perfusion and then the operation plan can be adjusted in time to ensure the flap survival.
Ye, Yuan; Yuan, Yi; Lu, Feng; Gao, Jianhua
2015-12-01
In plastic and reconstructive surgery, adipose tissue is widely used as effective filler for tissue defects. Strategies for treating soft tissue deficiency, which include free adipose tissue grafts, use of hyaluronic acid, collagen injections, and implantation of synthetic materials, have several clinical limitations. With the aim of overcoming these limitations, researchers have recently utilized tissue engineering chambers to produce large volumes of engineered vascularized fat tissue. However, the process of growing fat tissue in a chamber is still relatively limited, and can result in unpredictable or dissatisfactory final tissue volumes. Therefore, detailed understanding of the process is both necessary and urgent. Many studies have shown that mechanical force can change the function of cells via mechanotransduction. Here, we hypothesized that, besides the inflammatory response, one of the key factors to control the regeneration of vascularized fat flap inside a tissue engineering chamber might be the balance of mechanical forces. To test our hypothesis, we intend to change the balance of forces by means of measures in order to make the equilibrium point in favor of the direction of regeneration. If those measures proved to be feasible, they could be applied in clinical practice to engineer vascularized adipose tissue of predictable size and shape, which would in turn help in the advancement of tissue engineering. Copyright © 2015 Elsevier Ltd. All rights reserved.
The unique and valuable soft tissue free flap in head and neck reconstruction: Lateral arm.
Kang, Stephen Y; Eskander, Antoine; Patel, Krupal; Teknos, Theodoros N; Old, Matthew O
2018-07-01
While the lateral arm free flap has been well described, there is a relative paucity in its use compared to other free flaps and regional flaps. The lateral arm free flap is a unique soft tissue free flap that provides several reconstructive advantages in head and neck reconstruction: excellent contour and color match to facial skin, well compartmentalized fat, donor nerves for nerve grafting, and the ability to two-team harvest and close the donor site without a skin graft. A detailed anatomic and harvest technique is described, along with indications and advantages of using lateral free flap for head and neck reconstruction. A scoping literature review was also conducted to tabulate indications, overall success and complications of the flap. The lateral arm flap is a primary option for defects requiring soft tissue reconstruction in the head and neck. Copyright © 2018 Elsevier Ltd. All rights reserved.
Pont, Luis Parra; Marcelli, Stefano; Robustillo, Manuel; Song, Dajiang; Grandes, Daniel; Martin, Marcos; Iglesias, Israel; Aso, Jorge; Laloumet, Iñaki; Díaz, Antonio J
2017-10-01
The effects of postoperative radiotherapy on free flap-based breast reconstruction are still controversial. Poor outcomes, breast distortion, and fat necrosis have been traditionally documented. The aim of this study was to evaluate whether adjuvant radiotherapy affects the quality of life, satisfaction, and cosmetic result in patients undergoing immediate breast reconstruction with autologous free flap. Between January of 2013 and December of 2016, 230 patients underwent mastectomy with immediate free flap reconstruction at the authors' institution. Patients were divided into two groups depending on whether they received postmastectomy radiotherapy. Quality of life measured with the BREAST-Q questionnaire, self-reported aesthetic outcomes, and general satisfaction were assessed and compared. Fat necrosis of the flap and its severity were also analyzed as the main surgical outcomes. Mean follow-up time after reconstruction was 23 months (range, 6 to 48 months). No significant difference in quality of life or satisfaction scores were found between patients that underwent postmastectomy radiotherapy and patients who did not receive adjuvant radiotherapy. There were no significant differences in rates of fat necrosis between the groups (11.1 percent versus 13.76 percent; p = 0.75). Postmastectomy radiotherapy in patients undergoing immediate breast reconstruction with free flaps does not seem to affect quality of life, satisfaction with the outcome, or the cosmetic result as perceived by the patients. The potential need for postoperative radiotherapy should not hinder women from the benefits of autologous immediate breast reconstruction. Therapeutic, III.
Wolter, Andreas; Scholz, Till; Pluto, Naja; Diedrichson, Jens; Arens-Landwehr, Andreas; Liebau, Jutta
2017-12-01
Mastopexy in massive weight loss patients is challenging. The breast mound is often unstable and deflated, with a loose inelastic skin envelope. It has become apparent that mammaplasty techniques in these cases should rely more on glandular recontouring rather than on the skin envelope for shaping. Published methods include plication, suspension and autoaugmentation. The residual local tissue (glandular breast tissue, fat tissue, dermoglandular fat flap) is utilised to its full extent in order to reshape a form-stable breast with full upper pole projection. The evolution of a technique is presented. In this study we retrospectively analysed 68 massive weight loss patients who underwent an extended Ribeiro technique with a superomedial pedicle mastopexy and suspension by an inferior dermoglandular flap. The current procedure involves incorporating the lateral intercostal artery perforator flap (LICAP flap) and medial breast pillar additionally to the inferior dermoglandular Ribeiro flap. This essentially autoaugments the upper pole by creating an "autoprosthesis", narrows the widened breast, and redefines the inframammary fold. The outcome parameters complication rate, patient satisfaction with the aesthetic result, nipple sensibility and surgical revision rate were obtained. From 01/2011 to 12/2016, we performed 136 autoaugmentation mastopexies. The average age was 41.2 years, average body mass index (BMI) was 27,1 kg/m 2 , average weight loss was 54.3 kg, average sternal notch-NAC distance was 32.3 cm, average operation time was 109 minutes. In 12 breasts, a free-nipple graft was necessary. The complication rate was 5.1 %, surgical revision rate was 17.6 %. 95 % of the patients were "very satisfied" or "satisfied" with the aesthetic result. Nipple sensibility was rated as "very good" or "good" by 85 % of patients. Modification of the Ribeiro technique by using the medial and lateral breast pillar (LICAP flap) allows autoaugmentation of
Early experience with the free lumbar artery perforator flap for breast reconstruction.
Peters, Kevin T; Blondeel, Phillip N; Lobo, Fernando; van Landuyt, Koenraad
2015-08-01
Autologous breast reconstruction has become a progressively more popular method of breast reconstruction. A wide variety of perforator flaps have been described and subsequently refined to decrease donor-site morbidity. Recently, the lumbar artery perforator (LAP) flap has been reported as an option for autologous breast reconstruction. This study summarises the prospectively gathered data of 35 free LAP flaps for breast reconstruction in 28 patients. The mean follow-up was 18 months. The internal mammary artery and the venae comitantes were used as recipient vessels in all reconstructions. In 80% of the reconstructions (28 flaps), an interposition graft was used. Six flaps (17%) had to be revised for venous thrombosis. Two of the revised flaps (5.7%) could not be salvaged, and total flap necrosis occurred. The mean operating time was 6 h and 15 min, 6 h and 39 min when an interposition graft was used and 5 h and 23 min when no interposition graft was necessary. The LAP flap should be considered as a further alternative for breast reconstruction in patients in whom a deep inferior epigastric artery perforator (DIEAP) flap is not possible or not desirable. Shaping of this flap is easier compared to any other flaps due to the quality of the lumbar fat and the gluteal extension. An interposition graft is frequently used to facilitate anastomosis, either to lengthen the pedicle or to resolve size mismatch. This is a disadvantage of the LAP flap. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Flap preconditioning by pressure-controlled cupping in a rat model.
Koh, Kyung S; Park, Sung Woo; Oh, Tae Suk; Choi, Jong Woo
2016-08-01
Flap survival is essential for the success of soft-tissue reconstruction. Accordingly, various surgical and medical methods aim to increase flap survival. Because flap survival is affected by the innate vascular supply, traditional preconditioning methods mainly target vasodilatation or vascular reorientation to increase blood flow to the tissue. External stress on the skin, such as an external volume expander or cupping, induces vascular remodeling, and these approaches have been used in the fat grafting field and in traditional Asian medicine. In the present study, we used a rat random-pattern dorsal flap model to study the effectiveness of preconditioning with an externally applied device (cupping) at the flap site that directly applied negative pressure to the skin. The device, the pressure-controlled cupping, is connected to negative pressure vacuum device providing accurate pressure control from 0 mm Hg to -200 mm Hg. Flap surgery was performed after preconditioning under -25 mm Hg suction pressure for 30 min a day for 5 d, followed by 9 d of postoperative observation. Flap survival was assessed as the area of viable tissue and was compared between the preconditioned group and a control group. The preconditioned group showed absolute percentage increase of flap viability relative to the entire flap by 19.0± 7.6% (average 70.1% versus 51.0%). Tissue perfusion of entire flap, evaluated by laser Doppler imaging system, was improved with absolute percentage increase by 24.2± 10.4% (average 77.4% versus 53.1%). Histologic analysis of hematoxylin and eosin, CD31, and Masson-trichrome staining showed increased vascular density in the subdermal plexus and more organized collagen production with hypertrophy of the attached muscle. Our study suggests that flap preconditioning caused by controlled noninvasive suction induces vascular remodeling that increases tissue perfusion and improves flap survival in a rat model. Copyright © 2016 Elsevier Inc. All rights
Chae, Michael P; Hunter-Smith, David J; Rostek, Marie; Smith, Julian A; Rozen, Warren Matthew
2018-01-01
Optimizing preoperative planning is widely sought in deep inferior epigastric artery perforator (DIEP) flap surgery. One reason for this is that rates of fat necrosis remain relatively high (up to 35%), and that adjusting flap design by an improved understanding of individual perforasomes and perfusion characteristics may be useful in reducing the risk of fat necrosis. Imaging techniques have substantially improved over the past decade, and with recent advances in 3D printing, an improved demonstration of imaged anatomy has become available. We describe a 3D-printed template that can be used preoperatively to mark out a patient's individualized perforasome for flap planning in DIEP flap surgery. We describe this "perforasome template" technique in a case of a 46-year-old woman undergoing immediate unilateral breast reconstruction with a DIEP flap. Routine preoperative computed tomographic angiography was performed, with open-source software (3D Slicer, Autodesk MeshMixer and Cura) and a desktop 3D printer (Ultimaker 3E) used to create a template used to mark intra-flap, subcutaneous branches of deep inferior epigastric artery (DIEA) perforators on the abdomen. An individualized 3D printed template was used to estimate the size and boundaries of a perforasome and perfusion map. The information was used to aid flap design. We describe a new technique of 3D printing a patient-specific perforasome template that can be used preoperatively to infer perforasomes and aid flap design.
Hunter-Smith, David J.; Rostek, Marie; Smith, Julian A.; Rozen, Warren Matthew
2018-01-01
Summary: Optimizing preoperative planning is widely sought in deep inferior epigastric artery perforator (DIEP) flap surgery. One reason for this is that rates of fat necrosis remain relatively high (up to 35%), and that adjusting flap design by an improved understanding of individual perforasomes and perfusion characteristics may be useful in reducing the risk of fat necrosis. Imaging techniques have substantially improved over the past decade, and with recent advances in 3D printing, an improved demonstration of imaged anatomy has become available. We describe a 3D-printed template that can be used preoperatively to mark out a patient’s individualized perforasome for flap planning in DIEP flap surgery. We describe this “perforasome template” technique in a case of a 46-year-old woman undergoing immediate unilateral breast reconstruction with a DIEP flap. Routine preoperative computed tomographic angiography was performed, with open-source software (3D Slicer, Autodesk MeshMixer and Cura) and a desktop 3D printer (Ultimaker 3E) used to create a template used to mark intra-flap, subcutaneous branches of deep inferior epigastric artery (DIEA) perforators on the abdomen. An individualized 3D printed template was used to estimate the size and boundaries of a perforasome and perfusion map. The information was used to aid flap design. We describe a new technique of 3D printing a patient-specific perforasome template that can be used preoperatively to infer perforasomes and aid flap design. PMID:29464169
Timmermans, Floyd W; Westland, Pèdrou B; Hummelink, Stefan; Schreurs, Joep; Hameeteman, Marijn; Ulrich, Dietmar J O; Slater, Nicholas J
2018-06-01
The deep inferior epigastric artery perforator (DIEP) flap is one of the most common techniques for breast reconstruction. Body mass index (BMI) is considered as an important predictor of donor site healing complications such as wound dehiscence. The use of computed tomography (CT) proved to be a precise and objective method to assess visceral adipose tissue. It remains unclear whether quantification of visceral fat provides more accurate predictions of abdominal wound healing complications than BMI. A total of 97 patients with DIEP flap were retrospectively evaluated. Patients' abdominal visceral fat (AVF) was quantified on CT angiography (CTA). The patients were postoperatively assessed for abdominal wound healing complications. We analyzed for the correlations between AVF, BMI, and dehiscence and established a logistic regression model to assess the potential high-profile predictors in anatomic and patient characteristics such as weight, smoking, and diabetes. We included 97 patients, and of them, 24 patients (24.7%) had some degree of abdominal dehiscence. No significant differences were observed between the dehiscence group and the non-dehiscence group, except for smoking (p = 0.002). We found a significant correlation between AVF and BMI (R = 0.282, p = 0.005), but neither was significant in predicting donor site dehiscence. Smoking greatly increased the likelihood of developing wound dehiscence (OR = 11.4, p = < 0.001). AVF and BMI were not significant predictors of abdominal wound healing complications after DIEP flap reconstruction. This study established active smoking (OR = 11.4, p = < 0.001) as the significant risk factor that contributed to the development of abdominal wound dehiscence in patients with DIEP. Copyright © 2018 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Medial sural artery perforator flap: a challenging free flap.
Toyserkani, Navid Mohamadpour; Sørensen, Jens Ahm
Oral and extremity defect reconstruction can often require a flap that is thin, and traditionally, the radial forearm free flap has been used, however, this has significant donor site morbidity. Over the last decade, the medial sural artery perforator (MSAP) flap has emerged as a possible alternative with lower donor site morbidity. We present our experiences and review the literature regarding this promising but challenging flap. The study was a retrospective case series in a university hospital setting. All patients who had a MSAP flap performed at our institution were included until March 2015, and their data was retrieved from electronic patient records. In total, ten patients were reconstructed with a MSAP flap for floor of mouth (eight) and lower extremity (two) defect reconstruction. The median flap dimensions were as follows: 10 cm (range 7-14 cm), width 5 cm (range 3.5-8 cm), thickness 5 mm (range 4-8 mm), and pedicle length 10 cm (range 8-12 cm). In one case, the procedure was abandoned because of very small perforators and another flap was used. In two cases, late onset of venous congestion occurred which could not be salvaged. There were no donor site complaints. The MSAP flap is an ideal flap when a thin free flap is needed with lower donor site morbidity than alternative solutions. There seems to be a higher rate of late onset of venous thrombosis compared with more established flaps. Therefore, this flap should be monitored more closely for venous problems and we recommend performing two venous anastomoses when using this flap. Level of Evidence: Level IV, therapeutic study.
Free-style puzzle flap: the concept of recycling a perforator flap.
Feng, Kuan-Ming; Hsieh, Ching-Hua; Jeng, Seng-Feng
2013-02-01
Theoretically, a flap can be supplied by any perforator based on the angiosome theory. In this study, the technique of free-style perforator flap dissection was used to harvest a pedicled or free skin flap from a previous free flap for a second difficult reconstruction. The authors call this a free-style puzzle flap. For the past 3 years, the authors treated 13 patients in whom 12 pedicled free-style puzzle flaps were harvested from previous redundant free flaps and recycled to reconstruct soft-tissue defects at various anatomical locations. One free-style free puzzle flap was harvested from a previous anterolateral thigh flap for buccal cancer to reconstruct a foot defect. Total flap survival was attained in 12 of 13 flaps. One transferred flap failed completely. This patient had received postoperative radiotherapy after the initial cancer ablation and free anterolateral thigh flap reconstruction. Another free flap was used to close and reconstruct the wound. All the donor sites could be closed primarily. The free-style puzzle flap, harvested from a previous redundant free flap and used as a perforator flap to reconstruct a new defect, has proven to be versatile and reliable. When indicated, it is an alternative donor site for further reconstruction of soft-tissue defects.
The midabdominal TRAM flap for breast reconstruction in morbidly obese patients.
Gabbay, Joubin S; Eby, Joseph B; Kulber, David A
2005-03-01
The transverse rectus abdominis myocutaneous (TRAM) flap is ideal for postmastectomy reconstruction but is tenuous in morbidly obese patients. Because of their relatively high incidence of postoperative complications, morbidly obese patients are often not considered candidates for autogenous reconstruction. The midabdominal TRAM flap has a more favorable anatomy and may represent an alternative technique in this patient population. The records of 18 morbidly obese patients who underwent postmastectomy reconstruction using a mid-abdominal TRAM flap from 1998 through 2002 were retrospectively reviewed. The mid-abdominal TRAM flap territory includes more of the supraumbilical region than the traditional TRAM flap, corresponding to an area with more abundant musculocutaneous perforators and greater dependence on the superior epigastric vascular system. All patients underwent unipedicled mid-abdominal TRAM flap surgery. Four patients with previous subumbilical midline incisions had a delay procedure with ligation of the inferior epigastric vessels. Complications investigated were flap necrosis greater than 10 percent or sufficient to require surgical revision, abdominal donor-site breakdown, seroma formation, umbilical necrosis, abdominal wall bulging or hernia, deep vein thrombosis, infected mesh, surgical revisions, fat necrosis, and extended hospital stay. At a mean follow-up time of 15.6 months (range, 12 to 24 months), three patients had postoperative complications requiring surgical revision. Two of these patients had previous midline abdominal incisions. One patient had both partial flap necrosis and a donor-site complication. The second patient had partial flap necrosis, and the third had an abdominal donor-site complication. No occurrences of abdominal wall hernia, total flap loss, deep vein thrombosis, infected mesh, extensive surgical revision, or extended hospitalization were noted in this series. The mid-abdominal TRAM flap represents an alternative method
Free anterolateral thigh flap for reconstruction of major craniofacial defects.
Amin, Ayman; Rifaat, Mohammed; Civantos, Francisco; Weed, Donald; Abu-Sedira, Mohammed; Bassiouny, Mahmoud
2006-02-01
adequate dural cover and protection of the brain. Its size and moderate thickness are suitable for reconstruction of scalp and calvarial defects. The abundance of reliably vascularized fat in the flap may be an advantage in long-term maintenance of the volume of the flap in midface reconstruction. Similar to other soft tissue flaps, additional skeletal reconstruction may still be required to achieve an optimal functional and aesthetic result.
Breast-volume displacement using an extended glandular flap for small dense breasts.
Ogawa, Tomoko; Hanamura, Noriko; Yamashita, Masako; Kimura, Hiroko; Kashikura, Yumi
2011-01-01
We defined the glandular flap including fat in the subclavicular area as an extended glandular flap, which has been used for breast-conserving reconstruction in the upper portion of the breast. Indication. The excision volume was 20% to 40% of the breast volume, and the breast density was dense. Surgical Technique. The upper edge of the breast at the subclavicular area was drawn in the standing position before surgery. After partial mastectomy, an extended glandular flap was made by freeing the breast from both the skin and the pectoralis fascia up to the preoperative marking in the subclavicular area. It is important to keep the perforators of the internal mammary artery and/or the branches of the lateral thoracic artery intact while making the flap. Results. Seventeen patients underwent remodeling using an extended glandular flap. The cosmetic results at 1 year after the operation: excellent in 11, good in 1, fair in 3, and poor in 2. All cases of unacceptable outcome except one were cases with complications, and more than 30% resection of moderate or large size breasts did not obtain an excellent result for long-term followup. Conclusion. This technique is useful for performing the breast-conserving reconstruction of small dense breasts.
[Breast reconstruction by latissimus dorsi flap: Towards an evolution of ideas].
Niddam, J; Guihard, T; Cothier-Savey, I; Chaussard, H; Lemasurier, P
2015-12-01
Breast reconstruction with latissimus dorsi flap and fat grafting is a technique widely used in current practice. Some operators still complain at the lack of final results at the first intervention and the need for repeated lipofilling sessions. The objective of this study was to compare the number of reoperations in patients who underwent reconstruction with latissimus dorsi with prosthesis versus without prosthesis. We included all patients operated for breast reconstruction with latissimus dorsi flap, with or without prosthesis between 2008 and 2012 in our center. We noted the number of new surgical interventions in these patients on the reconstructed breast. We also noted the average weight of mastectomy in two groups each year. One hundred and eighty-six patients were included in this study. Ninety-one patients underwent reconstruction with latissimus dorsi and prosthesis, and 95 patients reconstruction by latissimus dorsi and fat graft. It has not been demonstrated significant differences in the number of new surgical procedures between the two groups. The average weight of mastectomies in the autologous group has steadily increased over the five years. There was no significant difference in the average weight of mastectomies between the two groups over the last two years. For breast reconstruction with latissimus dorsi flap, surgical indications changed in our center to the absence of prosthetic implant, whatever the volume of the breast. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Fat: friend or foe? A review of fat-containing masses within the head and neck.
Kale, Hrishikesh A; Prabhu, Arpan V; Sinelnikov, Andrey; Branstetter, Barton
2016-11-01
Fat-containing lesions of the head and neck are commonly encountered in day-to-day practice. Our aim was to review the various imaging presentations of common and some uncommon fat-containing lesions within the head and neck with potential pitfalls and mimics. While most soft-tissue masses have a fairly similar density, the presence of fat in a mass lesion is easy to identify on both CT/MRI and can help narrow the differential. Case-based examples of lipomas, liposarcomas, lipoblastomas, dermoids, teratomas and other fatty lesions will be used to describe imaging features. While fat density can be helpful, differentiating benign from malignant fat-containing lesions can still pose a challenge. Lesions simulating pathology such as brown fat, fatty changes within organs and post-operative flaps are presented. Finally, examples of fatty lesions in atypical locations are shown to illustrate examples that should be kept in mind in any differential. The presence of fat in head and neck masses can aid radiologists in arriving at an accurate diagnosis. Knowledge of the imaging appearance of these fat-containing lesions and their mimics can help avoid unnecessary biopsy or surgery.
Blondeel, P N
1999-04-01
The superior and inferior myocutaneous gluteal free flaps have been considered as valuable alternatives to the latissimus dorsi or TRAM flap since 1975. The superior gluteal artery perforator (S-GAP) flap is the ultimate refinement of this myocutaneous flap as no gluteus maximus muscle is harvested. The flap is vascularised by one single perforator originating from the superior gluteal artery. This study summarises the prospectively gathered data on 20 free S-GAP flaps used for breast reconstruction in 16 patients. Immediate reconstruction was performed in six breasts and delayed in 14 breasts. Mean follow-up was 11.1 months. Two risk factors, Raynaud's disease and radiotherapy, were the cause of flap revision in two different patients. Total flap loss occurred in one case. Partial flap loss was not observed and a small area of fat necrosis was diagnosed by mammography in one other patient. All flaps were anastomosed to the internal mammary vessels at the 3rd costochondral junction. The anatomy of the sensate nerves of the S-GAP flap is described. Two nervous repairs provided early sensory recovery. The free S-GAP flap has become my personal second choice for autologous breast reconstruction after the DIEP (deep inferior epigastric perforator) flap. The S-GAP flap is indicated in patients with an asthenic body habitus or with excessive abdominal scarring. The advantages are the abundance of adipose tissue in this area even in thin patients, a long vascular pedicle, a hidden scar, improved projection of the reconstructed breast compared to the DIEP and TRAM flaps and the preservation of the entire gluteus maximus muscle. The donor morbidity is extremely low.
The temporalis muscle flap and temporoparietal fascial flap.
Lam, Din; Carlson, Eric R
2014-08-01
The temporal arterial system provides reliable vascular anatomy for the temporalis muscle flap and temporoparietal fascial flap that can support multiple reconstructive needs of the oral and maxillofacial region. The minimal donor site morbidity and ease of development of these flaps result in their predictable and successful transfer for reconstructive surgery of the oral and maxillofacial region. Copyright © 2014 Elsevier Inc. All rights reserved.
A Model of Free Tissue Transfer: The Rat Epigastric Free Flap
Casal, Diogo; Pais, Diogo; Iria, Inês; Mota-Silva, Eduarda; Almeida, Maria-Angélica; Alves, Sara; Pen, Cláudia; Farinho, Ana; Mascarenhas-Lemos, Luís; Ferreira-Silva, José; Ferraz-Oliveira, Mário; Vassilenko, Valentina; Videira, Paula A.; Gory O'Neill, João
2017-01-01
Free tissue transfer has been increasingly used in clinical practice since the 1970s, allowing reconstruction of complex and otherwise untreatable defects resulting from tumor extirpation, trauma, infections, malformations or burns. Free flaps are particularly useful for reconstructing highly complex anatomical regions, like those of the head and neck, the hand, the foot and the perineum. Moreover, basic and translational research in the area of free tissue transfer is of great clinical potential. Notwithstanding, surgical trainees and researchers are frequently deterred from using microsurgical models of tissue transfer, due to lack of information regarding the technical aspects involved in the operative procedures. The aim of this paper is to present the steps required to transfer a fasciocutaneous epigastric free flap to the neck in the rat. This flap is based on the superficial epigastric artery and vein, which originates from and drain into the femoral artery and vein, respectively. On average the caliber of the superficial epigastric vein is 0.6 to 0.8 mm, contrasting with the 0.3 to 0.5 mm of the superficial epigastric artery. Histologically, the flap is a composite block of tissues, containing skin (epidermis and dermis), a layer of fat tissue (panniculus adiposus), a layer of striated muscle (panniculus carnosus), and a layer of loose areolar tissue. Succinctly, the epigastric flap is raised on its pedicle vessels that are then anastomosed to the external jugular vein and to the carotid artery on the ventral surface of the rat's neck. According to our experience, this model guarantees the complete survival of approximately 70 to 80% of epigastric flaps transferred to the neck region. The flap can be evaluated whenever needed by visual inspection. Hence, the authors believe this is a good experimental model for microsurgical research and training. PMID:28117814
Reading, G
1984-12-01
The instep island flap is safe and useful. It is based on branches of the posterior tibial artery and can be a musculocutaneous or a direct fasciocutaneous island flap. Sensory branches of the digital nerves may be transposed with the flap. There is a wide arc of transposition and the flap has survived even in very difficult circumstances.
Reduction of Flap Side Edge Noise - the Blowing Flap
NASA Technical Reports Server (NTRS)
Hutcheson, Florence V.; Brooks, THomas F.
2005-01-01
A technique to reduce the noise radiating from a wing-flap side edge is being developed. As an airplane wing with an extended flap is exposed to a subsonic airflow, air is blown outward through thin rectangular chord-wise slots at various locations along the side edges and side surface of the flap to weaken and push away the vortices that originate in that region of the flap and are responsible for important noise emissions. Air is blown through the slots at up to twice the local flow velocity. The blowing is done using one or multiple slots, where a slot is located along the top, bottom or side surface of the flap along the side edge, or also along the intersection of the bottom (or top) and side surfaces.
Fat necrosis in autologous abdomen-based breast reconstruction: a systematic review.
Khansa, Ibrahim; Momoh, Adeyiza O; Patel, Priti P; Nguyen, John T; Miller, Michael J; Lee, Bernard T
2013-03-01
Fat necrosis is a common and potentially exasperating complication of autologous breast reconstruction. The authors performed a systematic review of the English literature on autologous breast reconstruction to determine significant patient and surgical factors that are predictors of postoperative fat necrosis. A PubMed search using the terms "fat necrosis" and "breast reconstruction" was conducted. Articles were screened using predetermined inclusion and exclusion criteria. Data collected included patient characteristics, reconstructive techniques used, and the specific postoperative morbidity of interest. Patient cohorts were pooled, and the incidence of fat necrosis was calculated in the presence and absence of each risk factor. Chi-square analysis was applied, and p < 0.05 was considered statistically significant. Of 172 articles found, 70 met the inclusion criteria. The mean rate of fat necrosis was 11.3 percent. Deep inferior epigastric artery perforator flaps had the highest rate of fat necrosis (14.4 percent), followed by pedicled transverse rectus abdominis musculocutaneous (12.3 percent), superficial inferior epigastric artery (8.1 percent), and free transverse rectus abdominis musculocutaneous flaps (6.9 percent). Significant predictors of fat necrosis included obesity (p = 0.035), prereconstruction irradiation (p = 0.022), postreconstruction irradiation (p < 0.001), active smoking (p < 0.001), and abdominal scars (p = 0.05). Protective factors included supercharging (p < 0.001) and bilateral reconstruction (p = 0.01). Although there is little agreement in the literature regarding risk factors for fat necrosis, the authors were able to demonstrate several significant predictors by systematically analyzing 70 articles. Improved knowledge of the risk factors for fat necrosis can help surgeons provide improved preoperative counseling and take measures to minimize the risk of this complication.
Lower-limb reconstruction with chimeric flaps: The quad flap.
Azouz, Solomon M; Castel, Nikki A; Vijayasekaran, Aparna; Rebecca, Alanna M; Lettieri, Salvatore C
2018-05-07
Early soft-tissue coverage is critical for treating traumatic open lower-extremity wounds. As free-flap reconstruction evolves, injuries once thought to be nonreconstructable are being salvaged. Free-tissue transfer is imperative when there is extensive dead space or exposure of vital structures such as bone, tendon, nerves, or blood vessels. We describe 2 cases of lower-extremity crush injuries salvaged with the quad flap. This novel flap consists of parascapular, scapular, serratus, and latissimus dorsi free flaps in combination on one pedicle. This flap provides the large amount of soft-tissue coverage necessary to cover substantial defects from skin degloving, tibia and fibula fractures, and soft-tissue loss. In case 1, a 51-year-old woman was struck by an automobile and sustained bilateral tibia and fibula fractures, a crush degloving injury of the left leg, and a right forefoot traumatic amputation. She underwent reconstruction with a contralateral quad free flap. In case 2, a 53-year-old man sustained a right tibia plateau fracture with large soft-tissue defects from a motorcycle accident. He had a crush degloving injury of the entire anterolateral compartment over the distal and lower third of the right leg. The large soft-tissue defect was reconstructed with a contralateral quad flap. In both cases, the donor site was closed primarily and without early flap failures. There was one surgical complication, an abscess in case 2; the patient was taken back to the operating room for débridement of necrotic tissue. There have been no long-term complications in either case. Both patients achieved adequate soft-tissue coverage, avoided amputation, and had satisfactory aesthetic and functional outcomes. With appropriate surgical technique and patient selection, the quad-flap technique is promising for reconstructing the lower extremity. © 2018 Wiley Periodicals, Inc.
Dorafshar, Amir H; Januszyk, Michael; Song, David H
2010-08-01
Techniques for autologous breast reconstruction have evolved to minimize donor-site morbidity and reduce flap-specific complications. When available, the superficial inferior epigastric artery (SIEA) flap represents the optimal method to achieve the former. However, many microsurgeons have been reluctant to adopt this procedure due to technical challenges inherent to the surgery, as well as concerns with the intrinsic capacity of the superficial vessel system to adequately support this flap. This article sets forth a simple approach to the SIEA flap harvest and demonstrates that favorable results may be achieved even for small caliber vessels. A total of 46 patients underwent 53 SIEA breast reconstructions over a 6-year period using a modified approach for pedicle dissection and arterial inclusion criteria solely on the basis of presence of a palpable pulse. Average pedicle length harvested for all SIEA flaps was 6.07 cm; and mean arterial (0.96 mm) and venous (2.27 mm) diameters represent the lowest published values. Three flaps (5.7%) demonstrated fat necrosis or partial flap necrosis, with one (1.9%) complete flap loss. These results compare favorably with those of previous SIEA series employing diameter-based selection criteria, suggesting that the presence of a palpable arterial pulse may be sufficient to permit successful utilization of this flap. (c) Thieme Medical Publishers.
Wei, Fu-Chan; Mardini, Samir
2004-09-15
Free-tissue transfer has become the accepted standard for reconstruction of complex defects. With the growth of this field, anatomic studies and clinical work have added many flaps to the armamentarium of the microvascular surgeon. Further advancements and experience with techniques of perforator flap surgery have allowed for the harvest of flaps in a free-style manner, where a flap is harvested based only on the preoperative knowledge of Doppler signals present in a specific region. Between June of 2002 and September of 2003, 13 free-style free flaps were harvested from the region of the thigh. All patients presented with an oral or pharyngeal cancer and underwent resection and immediate reconstruction of these flaps. All flaps were cutaneous and were harvested in a suprafascial plane. The average size of the flaps was 108 cm2 (range, 36 to 187 cm2), and the average length of the vascular pedicle was 10 cm (range, 9 to 12 cm). All flaps were successful in achieving wound coverage and functional outcomes without any vascular compromise necessitating re-exploration. Free-style free flaps have become a clinical reality. The concepts and techniques used to harvest a free-style free flap will aid in dealing with anatomic variations that are encountered during conventional flap harvest. Future trends in flap selection will focus mainly on choosing tissue with appropriate texture, thickness, and pliability to match requirements at the recipient site while minimizing donor-site morbidity.
An innovative method of planning and displaying flap volume in DIEP flap breast reconstructions.
Hummelink, S; Verhulst, Arico C; Maal, Thomas J J; Hoogeveen, Yvonne L; Schultze Kool, Leo J; Ulrich, Dietmar J O
2017-07-01
Determining the ideal volume of the harvested flap to achieve symmetry in deep inferior epigastric artery perforator (DIEP) flap breast reconstructions is complex. With preoperative imaging techniques such as 3D stereophotogrammetry and computed tomography angiography (CTA) available nowadays, we can combine information to preoperatively plan the optimal flap volume to be harvested. In this proof-of-concept, we investigated whether projection of a virtual flap planning onto the patient's abdomen using a projection method could result in harvesting the correct flap volume. In six patients (n = 9 breasts), 3D stereophotogrammetry and CTA data were combined from which a virtual flap planning was created comprising perforator locations, blood vessel trajectory and flap size. All projected perforators were verified with Doppler ultrasound. Intraoperative flap measurements were collected to validate the determined flap delineation volume. The measured breast volume using 3D stereophotogrammetry was 578 ± 127 cc; on CTA images, 527 ± 106 cc flap volumes were planned. The nine harvested flaps weighed 533 ± 109 g resulting in a planned versus harvested flap mean difference of 5 ± 27 g (flap density 1.0 g/ml). In 41 out of 42 projected perforator locations, a Doppler signal was audible. This proof-of-concept shows in small numbers that flap volumes can be included into a virtual DIEP flap planning, and transferring the virtual planning to the patient through a projection method results in harvesting approximately the same volume during surgery. In our opinion, this innovative approach is the first step in consequently achieving symmetric breast volumes in DIEP flap breast reconstructions. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Experimental Study of Wake / Flap Interaction Noise and the Reduction of Flap Side Edge Noise
NASA Technical Reports Server (NTRS)
Hutcheson, Florence V.; Stead, Daniel J.; Plassman, Gerald E.
2016-01-01
The effects of the interaction of a wake with a half-span flap on radiated noise are examined. The incident wake is generated by bars of various widths and lengths or by a simplified landing gear model. Single microphone and phased array measurements are used to isolate the effects of the wake interaction on the noise radiating from the flap side edge and flap cove regions. The effects on noise of the wake generator's geometry and relative placement with respect to the flap are assessed. Placement of the wake generators upstream of the flap side edge is shown to lead to the reduction of flap side edge noise by introducing a velocity deficit and likely altering the instabilities in the flap side edge vortex system. Significant reduction in flap side edge noise is achieved with a bar positioned directly upstream of the flap side edge. The noise reduction benefit is seen to improve with increased bar width, length and proximity to the flap edge. Positioning of the landing gear model upstream of the flap side edge also leads to decreased flap side edge noise. In addition, flap cove noise levels are significantly lower than when the landing gear is positioned upstream of the flap mid-span. The impact of the local flow velocity on the noise radiating directly from the landing gear is discussed. The effects of the landing gear side-braces on flap side edge, flap cove and landing gear noise are shown.
Faris, Callum; van der Eerden, Paul; Vuyk, Hade
2015-01-01
This study clarifies the pedicle geometry and vascular supply of a midline forehead flap for nasal reconstruction. It reports on the vascular reliability of this flap and its ability to reduce hair transposition to the nose, a major complicating factor of previous forehead flap designs. To compare the vascular reliability of 3 different pedicle designs of the forehead flap in nasal reconstruction (classic paramedian, glabellar paramedian, and central artery flap design) and evaluate hair transposition rates and aesthetic results. Retrospective analysis of patient data and outcomes retrieved from computer files generated at the time of surgery, supplemented by data from the patient medical records and photographic documentation, from a tertiary referral nasal reconstructive practice, within a secondary-care hospital setting. The study population included all consecutive patients over a 19-year period who underwent primary forehead flap repair of nasal defects, with more than 3 months of postoperative follow-up and photographic documentation. Three sequential forehead flap patterns were used (classic paramedian flap, glabella flap, and central artery flap) for nasal reconstruction over the study duration. Data collected included patient characteristics, method of repair, complications, functional outcome, and patient satisfaction score. For cosmetic outcome, photographic documentation was scored by a medical juror. No forehead flap had vascular compromise in the first stage. Partial flap necrosis was reported in subsequent stages in 4 patients (1%), with no statistical difference in the rate of vascular compromise between the 3 flap designs. Hair transposition to the nose was lower in the central artery forehead flap (7%) compared with the classic paramedian (23%) and glabellar paramedian (13%) flaps (P < .05). Photographic evaluation in 227 patients showed that brow position (98%) and color match (83%) were good in the majority of the patients. In this series
Zhang, Ling; Yang, Qinghua; Jiang, Haiyue; Liu, Ge; Huang, Wanlu; Dong, Weiwei
2015-09-01
Reconstruction of complex facial defects using cervical expanded flap prefabricated by temporoparietal fascia flap. Complex facial defects are required to restore not only function but also aesthetic appearance, so it is vital challenge for plastic surgeons. Skin grafts and traditional flap transfer cannot meet the reconstructive requirements of color and texture with recipient. The purpose of this sturdy is to create an expanded prefabricated temporoparietal fascia flap to repair complex facial defects. Two patients suffered severe burns on the face underwent complex facial resurfacing with prefabricated cervical flap. The vasculature of prefabricated flap, including the superficial temporal vessel and surrounding fascia, was used as the vascular carrier. The temporoparietal fascia flap was sutured underneath the cervical subcutaneous tissue, and expansion was begun in postoperative 1 week. After 4 to 6 months of expansion, the expander was removed, facial scars were excised, and cervical prefabricated flap was elevated and transferred to repair the complex facial defects. Two complex facial defects were repaired successfully by prefabricated temporoparietal fascia flap, and prefabricated flaps survived completely. On account of donor site's skin was thinner and expanded too fast, 1 expanded skin flap was rupture during expansion, but necrosis was not occurred after the 2nd operation. Venous congestion was observed in 1 patient, but after dressing, flap necrosis was not happened. Donor site was closed primarily. Postoperative follow-up 6 months, the color, texture of prefabricated flap was well-matched with facial skin. This method of expanded prefabricated flap may provide a reliable solution to the complex facial resurfacing.
Chong, Chew-Wei; Lin, Cheng-Hung; Lin, Yu-Te; Hsu, Chung-Chen; Chen, Shih-Heng
2018-04-01
We described a laterally based cross-finger flap for reconstruction of soft tissue defects in the fingers. This modification enables coverage of volar or dorsal soft tissue defects at the distal, middle or proximal phalanx. From March 2015 to January 2017, a total of 12 patients (13 fingers) underwent soft tissue reconstruction of the fingers with a laterally based cross-finger flap. The flap dimensions ranged from 13 ×7 mm to 43 ×13 mm. Eleven of the 13 flaps survived completely. The two flap failures were attributed to injuries in the donor fingers, rendering the blood supply of the flaps unreliable. All donor sites were closed primarily without the need for skin grafting, negating the problem of donor site morbidity that is associated with skin graft harvesting. The laterally based cross-finger flap is a versatile flap with less donor site morbidity and better aesthetics than a conventional cross-finger flap. We described the design of the flap, as well as the advantages and disadvantages, in doing a laterally based cross-finger flap. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Yung, Matthew
2016-03-01
To find out if the use of the vascularized temporo-parietal fascial flap (TPFF) reduces postoperative infection or wound breakdown in subtotal petrosectomy for chronic discharging ears. A retrospective review on 26 subtotal petrosectomies with blind pit closures on chronic discharging ears performed by a single surgeon between 2000 and 2015 was performed. All patients had a minimum follow-up period of 6 months. Eleven mastoid cavities were obliterated with abdominal fat, and 15 cavities were obliterated with TPFF. There was no concomitant cochlear implant or middle ear implant. All postoperative wound infections or delay in wound healing were recorded into a database. The complication rates of the fat obliteration group were compared using Fisher's exact test with those for the TPFF obliteration group. In the fat obliteration group, 4 out of 11 patients had documented postoperative complications. Three had wound breakdown with exposure of the fat that required revision surgery. Another patient had postauricular abscess without the wound actually broken down. On the other hand, all the ears in the TPFF obliteration group (100%) were completely free of wound infection, wound breakdown, or any complication. The difference between the two groups was statistically significant (p = 0.022). Many authors have encountered postoperative infection or wound breakdown in subtotal petrosectomy with fat obliteration in the treatment of chronic otitis media. Using a richly vascularized temporo-temporal fascial flap to protect the blind pit closure in such patients reduces postoperative infection and wound breakdown.
Latissimus Dorsi Myocutaneous Flap for Breast Reconstruction: Bad Rap or Good Flap?
Perdikis, Galen; Koonce, Stephanie; Collis, George; Eck, Dustin
2011-01-01
Objective: This article serves to review latissimus dorsi myocutaneous flap as an option for breast reconstruction postmastectomy. Since the introduction of the latissimus dorsi myocutaneous flap in the late 1970s, its use has always been as a secondary technique, particularly after the development of the transverse rectus abdominus myocutaneous flap in the 1980s. Methods: A literature review of the history of latissimus dorsi myocutaneous flap utilized for breast reconstruction as well as a review of our institution's experience with latissimus dorsi myocutaneous flap and tissue expander placement was performed. Results: There remains a paucity of published studies investigating latissimus dorsi myocutaneous flap for breast reconstruction. Most studies have small numbers and do not utilize tissue expanders. More recently several small studies have been published that show acceptably low complication rates with aesthetically pleasing outcomes when latissimus dorsi myocutaneous flap is employed with a tissue expander. At our institution, we have employed latissimus dorsi myocutaneous flap with tissue expander placement for both delayed and immediate reconstruction with subsequent replacement with a permanent implant with a capsular contraction rate of 10.5%. Our data and others more recently published demonstrate very acceptable capsular contracture rates and aesthetic outcomes, particularly when an expander is utilized. Conclusion: The latissimus dorsi myocutaneous flap remains an excellent choice for breast reconstruction with a low risk of complications. PMID:22031843
Latissimus dorsi myocutaneous flap for breast reconstruction: bad rap or good flap?
Perdikis, Galen; Koonce, Stephanie; Collis, George; Eck, Dustin
2011-01-01
This article serves to review latissimus dorsi myocutaneous flap as an option for breast reconstruction postmastectomy. Since the introduction of the latissimus dorsi myocutaneous flap in the late 1970s, its use has always been as a secondary technique, particularly after the development of the transverse rectus abdominus myocutaneous flap in the 1980s. A literature review of the history of latissimus dorsi myocutaneous flap utilized for breast reconstruction as well as a review of our institution's experience with latissimus dorsi myocutaneous flap and tissue expander placement was performed. There remains a paucity of published studies investigating latissimus dorsi myocutaneous flap for breast reconstruction. Most studies have small numbers and do not utilize tissue expanders. More recently several small studies have been published that show acceptably low complication rates with aesthetically pleasing outcomes when latissimus dorsi myocutaneous flap is employed with a tissue expander. At our institution, we have employed latissimus dorsi myocutaneous flap with tissue expander placement for both delayed and immediate reconstruction with subsequent replacement with a permanent implant with a capsular contraction rate of 10.5%. Our data and others more recently published demonstrate very acceptable capsular contracture rates and aesthetic outcomes, particularly when an expander is utilized. The latissimus dorsi myocutaneous flap remains an excellent choice for breast reconstruction with a low risk of complications.
Ishii, Naohiro; Ando, Jiro; Harao, Michiko; Takemae, Masaru; Kishi, Kazuo
2018-05-07
In nipple reconstruction, the width, length, and thickness of modified star flaps are concerns for long-term reconstructed nipple projection. However, the flap's projection has not been analyzed, based on its thickness. The aim of the present study was to investigate how flap thickness in a modified star flap influences the resulting reconstructed nipple and achieves an appropriate flap width in design. Sixty-three patients who underwent nipple reconstruction using a modified star flap following implant-based breast reconstruction between August 2014 and July 2016 were included in this case-controlled study. The length of laterally diverging flaps was 1.5 times their width. The thickness of each flap was measured using ultrasonography, and the average thickness was defined as the flap thickness. We investigated the correlation between the resulting reconstructed nipple and flap thickness, and the difference of the change in the reconstructed nipple projection after using a thin or thick flap. The average flap thickness was 3.8 ± 1.7 (range 2.5-6.0) mm. There was a significant, linear correlation between the flap thickness and resulting reconstructed nipple projection (β = 0.853, p < 0.01). Furthermore, the difference between the thin and thick flaps in the resulting reconstructed nipple projection was significant (p < 0.01). Measuring the flap thickness preoperatively may allow surgeons to achieve an appropriate flap width; otherwise, alternative methods for higher projection might be used. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Yin, Xinghong; Hu, Wei; Zhang, Xinhai; Sun, Min
2014-10-01
To explore curative effect with pedicle flap of nasal septum-basis nasi and temporal muscucofascial flap to repair nasal septal perforation. Dissecting mucoperichondrium and mucoperioseptum around the perforation and taking dowm and out xia-ward to the floor of nasal cavity to make a inferior extremity pedicle flap. Then,the flap was tumbled and sutured onto raw surface of contralateral side through perforation. Reapplicating autoallergic temporal musculofascial flap to repair another side perforation. Repairing perforation Sin twelve cases were sucessfully healed in endoscope. The pedicle flap of nasal septum-basis nasi and temporal muscucofascial flap is easy to acquire and no rejection. The flap has good blood supplying, high survival rate and provides adequate transplantating materail to repair comparatively large perforation.
Li, Xiucun; Cui, Jianli; Maharjan, Suraj; Lu, Laijin; Gong, Xu
2016-01-01
Objective The purpose of this study is to determine the correlation between non-technical risk factors and the perioperative flap survival rate and to evaluate the choice of skin flap for the reconstruction of foot and ankle. Methods This was a clinical retrospective study. Nine variables were identified. The Kaplan-Meier method coupled with a log-rank test and a Cox regression model was used to predict the risk factors that influence the perioperative flap survival rate. The relationship between postoperative wound infection and risk factors was also analyzed using a logistic regression model. Results The overall flap survival rate was 85.42%. The necrosis rates of free flaps and pedicled flaps were 5.26% and 20.69%, respectively. According to the Cox regression model, flap type (hazard ratio [HR] = 2.592; 95% confidence interval [CI] (1.606, 4.184); P < 0.001) and postoperative wound infection (HR = 0.266; 95% CI (0.134, 0.529); P < 0.001) were found to be statistically significant risk factors associated with flap necrosis. Based on the logistic regression model, preoperative wound bed inflammation (odds ratio [OR] = 11.371,95% CI (3.117, 41.478), P < 0.001) was a statistically significant risk factor for postoperative wound infection. Conclusion Flap type and postoperative wound infection were both independent risk factors influencing the flap survival rate in the foot and ankle. However, postoperative wound infection was a risk factor for the pedicled flap but not for the free flap. Microvascular anastomosis is a major cause of free flap necrosis. To reconstruct complex or wide soft tissue defects of the foot or ankle, free flaps are safer and more reliable than pedicled flaps and should thus be the primary choice. PMID:27930679
Autologous breast reconstruction using the immediately lipofilled extended latissimus dorsi flap.
Johns, N; Fairbairn, N; Trail, M; Ewing, A; Yong, L; Raine, C; Dixon, J M
2018-02-01
The latissimus dorsi flap is a popular choice for autologous breast reconstruction. To dramatically improve volume, we report our experience of using the immediately lipofilled extended latissimus dorsi (ELD) flap and show it as a valid option for autologous breast reconstruction. Patients undergoing the procedure between December 2013 and June 2016 were included. Demographic, clinical and operative factors were analysed, together with in-hospital morbidity and duration of postoperative hospital stay. A total of 71 ELD flaps with immediate lipofilling were performed. Forty-five reconstructions were immediate and the remaining 26 delayed. Median (range) volume of autologous fat injected immediately was 171 ml (40-630 ml). Contralateral reductions were performed in 25 patients with the median reduction volume 185 g (89-683 g). Median duration of admission was 6.5 (3-18) days and patients were followed up for 12 months (1-37). Three total flap failures occurred and had to be excised (4%). One haematoma occurred requiring drainage (1%). Signs of infection requiring intravenous antibiotics occurred in five patients (7%). In 5 patients wound dehiscence occurred, and only two of these required resuturing (3%). In total, 7 patients developed a seroma requiring repeated drainage (10%). Three reconstructions experienced mild mastectomy flap necrosis with no needing reoperation (4%). Our experience represents the largest series to date and shows that in carefully selected patients the technique is safe, can avoid the requirement for implants, and has the potential to streamline the reconstructive journey. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Spanio di Spilimbergo, Stefano; Nordera, Paolo; Mardini, Samir; Castiglione, Giusy; Chim, Harvey; Pinna, Vittore; Brunello, Massimo; Cusino, Claudio; Roberto, Squaquara; Baciliero, Ugo
2017-02-01
In the past 130 years, the temporalis muscle flap has been used for a variety of different indications. In this age of microsurgery and perforator flaps, the temporalis muscle flap still has many useful applications for craniofacial reconstruction. Three hundred sixty-six temporalis muscle flaps were performed in a single center between 1978 and 2012. The authors divided the cases into two series-before and after 1994-because, after 1994, they started to perform free flap reconstructions, and indications for reconstruction with a temporalis muscle flap were changed RESULTS:: In the series after 1994, flaps were most commonly used for reconstruction of defects in the maxilla, mandible, and oropharynx, in addition to facial reanimation and filling of orbital defects. Complications included total flap necrosis (1.6 percent) and partial flap necrosis (10.7 percent). The rate of material extrusion at the donor site decreased after porous polyethylene was uniformly used for reconstruction from 17.1 to 7.9 percent. The pedicled temporalis muscle flap continues to have many applications in craniofacial reconstruction. With increasing use of free flaps, the authors' indications for the pedicled temporalis muscle flap are now restricted to (1) orbital filling for congenital or acquired anophthalmia; (2) filling of unilateral maxillectomy defects; and (3) facial reanimation in selected cases of facial nerve palsy. Therapeutic, IV.
Aerodynamics power consumption for mechanical flapping wings undergoing flapping and pitching motion
NASA Astrophysics Data System (ADS)
Razak, N. A.; Dimitriadis, G.; Razaami, A. F.
2017-07-01
Lately, due to the growing interest in Micro Aerial Vehicles (MAV), interest in flapping flight has been rekindled. The reason lies in the improved performance of flapping wing flight at low Reynolds number regime. Many studies involving flapping wing flight focused on the generation of unsteady aerodynamic forces such as lift and thrust. There is one aspect of flapping wing flight that received less attention. The aspect is aerodynamic power consumption. Since most mechanical flapping wing aircraft ever designed are battery powered, power consumption is fundamental in improving flight endurance. This paper reports the results of experiments carried out on mechanical wings under going active root flapping and pitching in the wind tunnel. The objective of the work is to investigate the effect of the pitch angle oscillations and wing profile on the power consumption of flapping wings via generation of unsteady aerodynamic forces. The experiments were repeated for different airspeeds, flapping and pitching kinematics, geometric angle of attack and wing sections with symmetric and cambered airfoils. A specially designed mechanical flapper modelled on large migrating birds was used. It will be shown that, under pitch leading conditions, less power is required to overcome the unsteady aerodnamics forces. The study finds less power requirement for downstroke compared to upstroke motion. Overall results demonstrate power consumption depends directly on the unsteady lift force.
Duncumb, Joseph W; Miyagi, Kana; Forouhi, Parto; Malata, Charles M
2016-01-01
Abdominal free flaps for microsurgical breast reconstruction are most commonly harvested based on the deep inferior epigastric vessels that supply skin and fat via perforators through the rectus muscle and sheath. Intact perforator anatomy and connections are vital for subsequent optimal flap perfusion and avoidance of necrosis, be it partial or total. The intraflap vessels are delicate and easily damaged and it is generally advised that patients should avoid heparin injection into the abdominal pannus preoperatively as this may compromise the vascular perforators through direct needle laceration, pressure from bruising, haematoma formation, or perforator thrombosis secondary to external compression. We report three cases of successful deep inferior epigastric perforator (DIEP) flap harvest despite patients injecting therapeutic doses of low molecular weight heparin into their abdomens for thrombosed central venous lines (portacaths™) used for administering primary chemotherapy in breast cancer.
Miyagi, Kana; Forouhi, Parto
2016-01-01
Abdominal free flaps for microsurgical breast reconstruction are most commonly harvested based on the deep inferior epigastric vessels that supply skin and fat via perforators through the rectus muscle and sheath. Intact perforator anatomy and connections are vital for subsequent optimal flap perfusion and avoidance of necrosis, be it partial or total. The intraflap vessels are delicate and easily damaged and it is generally advised that patients should avoid heparin injection into the abdominal pannus preoperatively as this may compromise the vascular perforators through direct needle laceration, pressure from bruising, haematoma formation, or perforator thrombosis secondary to external compression. We report three cases of successful deep inferior epigastric perforator (DIEP) flap harvest despite patients injecting therapeutic doses of low molecular weight heparin into their abdomens for thrombosed central venous lines (portacaths™) used for administering primary chemotherapy in breast cancer. PMID:27651974
Dancing girl flap: a new flap suitable for web release.
Shinya, K
1999-12-01
To create a deep web, a flap must be designed to have a high elongation effect in one direction along the mid-lateral line of the finger and also to have a shortening effect in the other direction, crossing at a right angle to the mid-lateral line. The dancing girl flap is a modification of a four-flap Z-plasty with two additional Z-plasties. It has a high elongation effect in one direction (>550%) and a shortening effect in the other direction at a right angle (<33%), creating a deep, U-shaped surface. This new flap can be used to release severe scar contracture with a web, and is most suitable for incomplete syndactyly with webs as high as the proximal interphalangeal joint.
PIV Measurements on a Blowing Flap
NASA Technical Reports Server (NTRS)
Hutcheson, Florence V.; Stead, Daniel J.
2004-01-01
PIV measurements of the flow in the region of a flap side edge are presented for several blowing flap configurations. The test model is a NACA 63(sub 2)-215 Hicks Mod-B main-element airfoil with a half-span Fowler flap. Air is blown from small slots located along the flap side edge on either the top, bottom or side surfaces. The test set up is described and flow measurements for a baseline and three blowing flap configurations are presented. The effects that the flap tip jets have on the structure of the flap side edge flow are discussed for each of the flap configurations tested. The results indicate that blowing air from a slot located along the top surface of the flap greatly weakened the top vortex system and pushed it further off the top surface. Blowing from the bottom flap surface kept the strong side vortex further outboard while blowing from the side surface only strengthened the vortex system or accelerated the merging of the side vortex to the flap top surface. It is concluded that blowing from the top or bottom surfaces of the flap may lead to a reduction of flap side edge noise.
Manrique, Oscar J; Bishop, Sarah N; Ciudad, Pedro; Adabi, Kian; Martinez-Jorge, Jorys; Moran, Steven L; Huang, Tony; Vijayasekaran, Aparna; Chen, Shih-Heng; Chen, Hung-Chi
2018-05-16
Lower extremity salvage following significant soft tissue loss can be complicated by lack of recipient vessel for free tissue transfer. We describe our experience in lower limb salvage for patients with no recipient vessels with the use of pedicle, free and cable bridge flaps. A retrospective review from 1985 to 2017 of patients undergoing lower limb salvage using a contralateral pedicle cross leg (PCL) flaps, free cross leg (FCL) flaps, or free cable bridge (FCB) flaps was conducted. Demographics, etiology of the reconstruction, type of flap used, donor-site vessels, defect size, operating time, time of pedicle division, length of hospital stay, time to ambulation, and complications were analyzed. A total of 53 patients (48 males and 5 females) with an average age of 35 years (range, 29-38 years) were identified. The etiology for the reconstruction was trauma in 52 patients and oncological resection in 1 patient. There were 18 PCL, 25 FCL, and 10 FCB completed. The recipient vessels for all flaps were the posterior tibial artery and vein. The average operating room times for PCL, FCL, and FCB flaps were 4, 9, and 10 hours, respectively. The average length of hospital stay was 5 weeks and average time to ambulation was 4 weeks. The average follow-up time was 7.5 years (range, 3-12 years). Complications encountered were hematoma (six), prolonged pain (six), total flap loss (two), reoperation (five), and infection (four). Limb salvage rates were 96.2%. When ipsilateral limb vessels are not available, and other reconstructive options have been exhausted, cross leg flaps can be a viable option for limb salvage in the setting of extensive defects. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Navier-Stokes Computations of a Wing-Flap Model With Blowing Normal to the Flap Surface
NASA Technical Reports Server (NTRS)
Boyd, D. Douglas, Jr.
2005-01-01
A computational study of a generic wing with a half span flap shows the mean flow effects of several blown flap configurations. The effort compares and contrasts the thin-layer, Reynolds averaged, Navier-Stokes solutions of a baseline wing-flap configuration with configurations that have blowing normal to the flap surface through small slits near the flap side edge. Vorticity contours reveal a dual vortex structure at the flap side edge for all cases. The dual vortex merges into a single vortex at approximately the mid-flap chord location. Upper surface blowing reduces the strength of the merged vortex and moves the vortex away from the upper edge. Lower surface blowing thickens the lower shear layer and weakens the merged vortex, but not as much as upper surface blowing. Side surface blowing forces the lower surface vortex farther outboard of the flap edge by effectively increasing the aerodynamic span of the flap. It is seen that there is no global aerodynamic penalty or benefit from the particular blowing configurations examined.
The "Tokyo" consensus on propeller flaps.
Pignatti, Marco; Ogawa, Rei; Hallock, Geoffrey G; Mateev, Musa; Georgescu, Alexandru V; Balakrishnan, Govindasamy; Ono, Shimpei; Cubison, Tania C S; D'Arpa, Salvatore; Koshima, Isao; Hyakusoku, Hikko
2011-02-01
Over the past few years, the use of propeller flaps, which base their blood supply on subcutaneous tissue or isolated perforators, has become increasingly popular. Because no consensus has yet been reached on terminology and nomenclature of the propeller flap, different and confusing uses of the term can be found in the literature. In this article, the authors report the consensus on the definition and classification of propeller flaps reached by the authors that gathered at the First Tokyo Meeting on Perforator and Propeller Flaps in June of 2009. Some peculiar aspects of the surgical technique are discussed. A propeller flap can be defined as an "island flap that reaches the recipient site through an axial rotation." The classification is based on the nourishing pedicle (subcutaneous pedicled propeller flap, perforator pedicled propeller flap, supercharged propeller flap), the degrees of skin island rotation (90 to 180 degrees) and, when possible, the artery of origin of the perforator. The propeller flap is a useful reconstructive tool that can achieve good cosmetic and functional results. A flap should be called a propeller flap only if it fulfils the definition above. The type of nourishing pedicle, the source vessel (when known), and the degree of skin island rotation should be specified for each flap.
Tan, Shane; Yek, Jacklyn; Ong, Wei Chen; Hing, Chor Hoong; Lim, Thiam Chye
2013-01-01
Background Our objective was to compare the complication rates of two common breast reconstruction techniques performed at our hospital and the cost-effectiveness for each test group. Methods All patients who underwent deep inferior epigastric perforator (DIEP) flap and transverse rectus abdominis myocutaneous (TRAM) flap by the same surgeon were selected and matched according to age and mastectomy with or without axillary clearance. Patients from each resultant group were selected, with the patients matched chronologically. The remainder were matched for by co-morbidities. Sixteen patients who underwent immediate breast reconstruction with pedicled TRAM flaps and 16 patients with DIEP flaps from 1999 to 2006 were accrued. The average total hospitalisation cost, length of hospitalisation, and complications in the 2 year duration after surgery for each group were compared. Results Complications arising from both the pedicled TRAM flaps and DIEP flaps included fat necrosis (TRAM, 3/16; DIEP, 4/16) and other minor complications (TRAM, 3/16; DIEP, 1/16). The mean hospital stay was 7.13 days (range, 4 to 12 days) for the pedicled TRAM group and 7.56 (range, 5 to 10 days) for the DIEP group. Neither the difference in complication rates nor in hospital stay duration were statistically significant. The total hospitalisation cost for the DIEP group was significantly higher than that of the pedicled TRAM group (P<0.001). Conclusions Based on our study, the pedicled TRAM flap remains a cost-effective technique in breast reconstruction when compared to the newer, more expensive and tedious DIEP flap. PMID:23730591
Noise Reduction of Aircraft Flap
NASA Technical Reports Server (NTRS)
Hutcheson, Florence V. (Inventor); Brooks, Thomas F. (Inventor)
2009-01-01
A reduction in noise radiating from a side of a deployed aircraft flap is achieved by locating a slot adjacent the side of the flap, and then forcing air out through the slot with a suitable mechanism. One, two or even three or more slots are possible, where the slot is located at one;or more locations selected from a group of locations comprising a top surface of the flap, a bottom surface of the flap, an intersection of the top and side surface of the flap, an intersection of the bottom and side surfaces of the flap, and a side surface of the flap. In at least one embodiment the slot is substantially rectangular. A device for adjusting a rate of the air forced out through the slot can also be provided.
New model of flap-gliding flight.
Sachs, Gottfried
2015-07-21
A new modelling approach is presented for describing flap-gliding flight in birds and the associated mechanical energy cost of travelling. The new approach is based on the difference in the drag characteristics between flapping and non-flapping due to the drag increase caused by flapping. Thus, the possibility of a gliding flight phase, as it exists in flap-gliding flight, yields a performance advantage resulting from the decrease in the drag when compared with continuous flapping flight. Introducing an appropriate non-dimensionalization for the mathematical relations describing flap-gliding flight, results and findings of generally valid nature are derived. It is shown that there is an energy saving of flap-gliding flight in the entire speed range compared to continuous flapping flight. The energy saving reaches the highest level in the lower speed region. The travelling speed of flap-gliding flight is composed of the weighted average of the differing speeds in the flapping and gliding phases. Furthermore, the maximum range performance achievable with flap-gliding flight and the associated optimal travelling speed are determined. Copyright © 2015 Elsevier Ltd. All rights reserved.
Management of Dropped Skull Flaps.
Abdelfatah, Mohamed AbdelRahman
2017-01-01
Dropping a skull flap on the floor is an uncommon and avoidable mistake in the neurosurgical operating theater. This study retrospectively reviewed all incidents of dropped skull flaps in Ain-Shams University hospitals during a 10-year period to show how to manage this problem and its outcome. Thirty-one incidents of dropped skull flaps occurred from January 2004 to January 2014 out of more than 10,000 craniotomies. Follow-up period varied from 20 to 44 months. The bone flap was dropped while elevating the bone (n = 16), while drilling the bone on the operating table (n = 5), and during insertion of the bone flap (n = 10). Treatment included re-insertion of the skull flap after soaking it in povidone iodine and antibiotic solution (n = 17) or after autoclaving (n = 11), or discarding the skull flap and replacing it with a mesh cranioplasty in the same operation (n = 3). No bone or wound infection was noted during the follow-up period. Management of dropped skull flap is its prevention. Replacement of the skull flap, after decontamination, is an option that avoids the expense and time of cranioplasty.
Li, Qingfeng; Zan, Tao; Gu, Bin; Liu, Kai; Shen, Guoxiong; Xie, Yun; Weng, Rui
2009-01-01
Resurfacing of facial massive soft tissue defect is a formidable challenge because of the unique character of the region and the limitation of well-matched donor site. In this report, we introduce a technique for using the prefabricated cervicothoracic skin flap for facial resurfacing, in an attempt to meet the principle of flap selection in face reconstructive surgery for matching the color and texture, large dimension, and thinner thickness (MLT) of the recipient. Eleven patients with massive facial scars underwent resurfacing procedures with prefabricated cervicothoracic flaps. The vasculature of the lateral thigh fascial flap, including the descending branch of the lateral femoral circumflex vessels and the surrounding muscle fascia, was used as the vascular carrier, and the pedicles of the fascial flap were anastomosed to either the superior thyroid or facial vessels in flap prefabrication. A tissue expander was placed beneath the fascial flap to enlarge the size and reduce the thickness of the flap. The average size of the harvested fascia flap was 6.5 x 11.7 cm. After a mean interval of 21.5 weeks, the expanders were filled to a mean volume of 1,685 ml. The sizes of the prefabricated skin flaps ranged from 12 x 15 cm to 15 x 32 cm. The prefabricated skin flaps were then transferred to the recipient site as pedicled flaps for facial resurfacing. All facial soft tissue defects were successfully covered by the flaps. The donor sites were primarily closed and healed without complications. Although varied degrees of venous congestion were developed after flap transfers, the marginal necrosis only occurred in two cases. The results in follow-up showed most resurfaced faces restored natural contour and regained emotional expression. MLT is the principle for flap selection in resurfacing of the massive facial soft tissue defect. Our experience in this series of patients demonstrated that the prefabricated cervicothoracic skin flap could be a reliable alternative
Propeller flaps in eyelid reconstruction.
Rajak, Saul N; Huilgol, Shyamala C; Murakami, Masahiro; Selva, Dinesh
2018-03-14
Propeller flaps are island flaps that reach the recipient site through an axial rotation. The flap has a subcutaneous pedicle on which it pivots, thereby resembling a helicopter propeller. We present our series of propeller flaps for the reconstruction of large eyelid defects. This is a retrospective review of the clinical case notes of eight patients that underwent tumour excision with reconstruction with a cutaneous propeller flap supplied by a non-perforator orbicularis pedicle between July and December 2016. Propeller flaps were used in the reconstruction of five lower lid defects (size range 19 × 5 mm to 25 × 8 mm), one medial canthus defect (13 mm diameter), one complete upper lid defect (42 × 19 mm diameter) and one lid sparing extenteration defect. The flaps were recruited from nasolabial, lateral canthal, temple or medial upper cheek skin. Post-operatively one case had 'trapdooring' which required flap revision at 4 months and one had persistent oedema that settled without intervention. The reconstruction of large eyelid defects is challenging in part because of the paucity of locally available skin. Propeller flaps are a paradigm shift in periocular reconstruction in which the subcutaneous pedicle enables the recruitment of large and highly mobile skin flaps from a wide area of regional tissue.
Chen, Yen-Chou; Huang, Eng-Yen; Lin, Pao-Yuan
2014-03-01
The gluteus maximus myocutaneous flap was considered the workhorse that reconstructed sacral pressure sores, but was gradually replaced by fasciocutaneous flap because of several disadvantages. With the advent of the perforator flap technique, gluteal perforator (GP) flap has gained popularity nowadays. The aim of this study was to compare the complications and outcomes between GP flaps and gluteal fasciocutaneous rotation (FR) flaps in the treatment of sacral pressure sores. Between April 2007 and June 2012, 63 patients underwent sacral pressure sore reconstructions, with a GP flap used in 31 cases and an FR flap used in 32 cases. Data collected on the patients included patient age, gender, co-morbidity for being bedridden and follow-up time. Surgical details collected included the defect size, operative time and estimated blood loss. Complications recorded included re-operation, dehiscence, flap necrosis, wound infection, sinus formation, donor-site morbidity and recurrence. The complications and clinical outcomes were compared between these two groups. We found that there was no significant difference in patient demographics, surgical complications and recurrence between these two groups. In gluteal FR flap group, all recurrent cases (five) were treated by reuse of previous flaps. Both methods are comparable, good and safe in treating sacral pressure sores. Gluteal FR flap can be performed without microsurgical dissection, and re-rotation is feasible in recurrent cases. The authors suggest using gluteal FR flaps in patients with a high risk of sore recurrence. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
On the generation of side-edge flap noise. [part span trailing edge flaps
NASA Technical Reports Server (NTRS)
Howe, M. S.
1981-01-01
A theory is proposed for estimating the noise generated at the side edges of part span trailing edge flaps in terms of pressure fluctuations measured just in-board of the side edge of the upper surface of the flap. Asymptotic formulae are developed in the opposite extremes of Lorentz contracted acoustic wavelength large/small compared with the chord of the flap. Interpolation between these limiting results enables the field shape and its dependence on subsonic forward flight speed to be predicted over the whole frequency range. It is shown that the mean width of the side edge gap between the flap and the undeflected portion of the airfoil has a significant influence on the intensity of the radiated sound. It is estimated that the noise generated at a single side edge of a full scale part span flap can exceed that produced along the whole of the trailing edge of the flap by 3 dB or more.
Delikonstantinou, Iraklis P; Gravvanis, Andreas I; Dimitriou, Vasilios; Zogogiannis, Ioannis; Douma, Amalia; Tsoutsos, Dimosthenis A
2011-08-01
Our study aims to illustrate the advantages and disadvantages of Foucher's first dorsal metacarpal artery flap and Littler's heterodigital neurovascular flap in thumb pulp reconstruction, by assessing wound healing of donor and recipient sites, sensibility, and functional outcome of the reconstructed thumb. Fourteen male patients were reconstructed either with Foucher (n = 8) or Littler flap (n = 6). Dissection of Foucher's flap was faster than that of Littler's flap. All Littler flaps survived completely, but we experienced 1 partial Foucher flap necrosis. Thumb motility and stability was optimal in all patients. Wound healing of donor sites was achieved in both groups. Two patients reconstructed with Littler flap developed scar contractures and presented a reduced range of motion of donor finger and first webspace, respectively. Although Littler flap resulted in better sensibility and tactile gnosis of the reconstructed thumb-pulp, Foucher flap ensured negligible donor site morbidity, complete cortical reorientation, and better overall hand function.
[Free vascularized popliteal artery cutaneous branch flap for repair of wound on foot and ankle].
Shen, Lilin; Song, Suping; Lin, Cuixia; Li, Wenlong; Sun, Xuesheng; Zhu, Tao; Li, Qiang
2014-01-01
To investigate the feasibility and effectiveness of free popi iteal artery cutaneous branch flap anastomosed with lateral tarsal artery and vein for the repair of wound on the foot and ankle by anatomical observation and clinical application. Latex was poured into the blood vessels of 8 cadavers, then perforator vessel of posterolateral upper calf was dissected, and the popl iteal artery cutaneous branch flap was designed with a pedicle of 2.5 cm in length; the lateral tarsal artery of the foot was dissected, could be freed to 6 cm in length; the diameter of these vessels was measured, and the number of the accompanying veins was counted. Between March 2010 and January 2013, 13 cases of foot and ankle wounds were repaired with popliteal artery cutaneous branch flap anastomosed with lateral tarsal artery and vein. The size of flaps ranged from 6.0 cm x 4.0 cm to 7.5 cm x 5.5 cm. There were 11 males and 2 females, aged from 41 to 65 years (mean, 47.3 years). The causes of injury included traffic accident in 8 cases, crushing in 4 cases, and twist by machine in 1 case. The size of wounds, ranged from 5.0 cm x 3.5 cm to 7.0 cm x 5.0 cm. The donor sites were sutured directly. According to anatomical observation, the popliteal artery cutaneous branch flap was designed by using the lateral popliteal artery perforator for shaft. The vessel of the pedicle perforator flaps from the popliteal artery cutaneous branch flap matched well with the lateral tarsal artery. vascular crisis occurred in 2 flaps, which survived after symptomatic treatment; the other flaps survived, with primary healing of wound and incision at donor site. The patients were all followed up 5-18 months (mean, 11 months). The flap had normal color and good elasticity. Second stage operation was performed to make the flap thinner in 3 female patients because of bulky flaps. The remaining patients had no obvious fat flap. According to American Orthopaedic Foot and Ankle Society (AOFAS) score for evaluation of
Tenekeci, Goktekin; Basterzi, Yavuz; Unal, Sakir; Sari, Alper; Demir, Yavuz; Bagdatoglu, Celal; Tasdelen, Bahar
2018-04-09
Bilateral rotation flaps are considered the workhorse flaps in reconstruction of myelomeningocele defects. Since the introduction of perforator flaps in the field of reconstructive surgery, perforator flaps have been used increasingly in the reconstruction of various soft tissue defects all over the body because of their appreciated advantages. The aim of this study was to compare the complications and surgical outcomes between bilateral rotation flaps and dorsal intercostal artery perforator (DICAP) flaps in the soft tissue reconstruction of myelomeningocele defects. Between January 2005-February 2017, we studied 47 patients who underwent reconstruction of myelomeningocele defects. Patient demographics, operative data, and postoperative data were reviewed retrospectively and are included in the study. We found no statistically significant differences in patient demographics and surgical complications between these two groups; this may be due to small sample size. With regard to complications-partial flap necrosis, cerebrospinal fluid (CSF) leakage, necessity for reoperation, and wound infection-DICAP propeller flaps were clinically superior to rotation flaps. Partial flap necrosis was associated with CSF leakage and wound infection, and CSF leakage was associated with wound dehiscence. Although surgical outcomes obtained with DICAP propeller flaps were clinically superior to those obtained with rotation flaps, there was no statistically significant difference between the two patient groups. A well-designed comparative study with adequate sample size is needed. Nonetheless, we suggest using DICAP propeller flaps for reconstruction of large myelomeningocele defects.
NASA Technical Reports Server (NTRS)
Dorsch, R. G.; Kreim, W. J.; Olsen, W. A.
1972-01-01
Noise data were obtained with a large externally blown flap model. A fan-jet engine exhaust was simulated by a 1/2-scale bypass nozzle supplied by pressurized air. The nozzle was pylon mounted on a wing section having a double-slotted flap for lift augmentation. Noise radiation patterns and spectra were obtained for nozzle exhaust velocities between 400 and 1150 ft/sec. The blown flap noise data are in good agreement with previous small model results extrapolated to test conditions by Strouhal scaling. The results indicate that blown flap noise must be suppressed to meet STOL aircraft noise goals.
Superficial ulnar artery perforator flap.
Schonauer, Fabrizio; Marlino, Sergio; Turrà, Francesco; Graziano, Pasquale; Dell'Aversana Orabona, Giovanni
2014-09-01
Superficial ulnar artery is a rare finding but shows significant surgical implications. Its thinness and pliability make this flap an excellent solution for soft tissue reconstruction, especially in the head and neck region. We hereby report a successful free superficial ulnar artery perforator forearm flap transfer for tongue reconstruction. A 64-year-old man presenting with a squamous cell carcinoma of the left tongue underwent a wide resection of the tumor, left radical neck dissection, and reconstruction of the tongue and the left tonsillar pillar with the mentioned flap. No complications were observed postoperatively. The flap survived completely; no recurrence at 6 months of follow-up was detected. Superficial ulnar artery perforator flap has shown to be a safe alternative to other free tissue flaps in specific forearm anatomic conditions.
Datli, Asli; Suh, HyunSuk; Kim, Young Chul; Choi, Doon Hoon; Hong, Joon Pio Jp
2017-03-01
The reconstruction of the posterior trunk, especially with large dead spaces, remains challenging. Regional muscle flaps may lack adequate volume and reach. The purpose of this report was to evaluate the efficacy of deepithelialized free-style perforator-based propeller flaps to obliterate defects with large dead space. A total of 7 patients with defects on the posterior trunk with large dead spaces were evaluated. After complete debridement or resection, all flaps were designed on a single perforator adjacent to the defect, deepithelialized, and then rotated in a propeller fashion. Flaps were further modified in some cases such as folding the flap after deepithelialization to increase bulk and to obliterate the dead space. The flap dimension ranged from 10 × 5 × 1 to 15 × 8 × 2.5 cm based on a single perforator. The rotation arch of the flap ranged from 90 to 180 degrees. Uneventful healing was noted in all cases. One case showed latent redness and swelling at 7 months after falling down, which resolved with medication. During the average follow-up of 28 months, there were no other flap and donor site complications. The deepithelialized propeller flap can be used efficiently to obliterate dead spaces in the posterior trunk and retains advantages such as having a good vascular supply, adequate bulk, sufficient reach without tension, and minimal donor site morbidity.
Venous coupler use for free-flap breast reconstructions: specific analyses of TMG and DIEP flaps.
Bodin, Frédéric; Brunetti, Stefania; Dissaux, Caroline; Erik, A Sauleau; Facca, Sybille; Bruant-Rodier, Catherine; Liverneaux, Philippe
2015-05-01
The purpose of this report was to present the results of comparisons of anastomotic data and flap complications in the use of venous coupler in breast reconstruction with the transverse musculocutaneous gracilis (TMG) flap and the deep inferior epigastric perforator (DIEP) flap. Over a three-year period, 95 patients suffering from breast cancer were treated with mastectomy and breast reconstruction using free flaps. We performed 121 mechanical venous anastomoses for 105 flap procedures (80 DIEP and 25 TMG). The coupler size, anastomotic duration, number of anastomoses and postoperative complications were assessed for the entire series. The coupling device was perfectly suitable for all end-to-end anastomoses between the vein(s) of the flap and the internal mammary vein(s). No venous thrombosis occurred. The mean anastomotic time did not significantly differ between the DIEP (330 seconds) and TMG flap procedures (352 seconds) (P = 0.069). Additionally, there were no differences in coupling time observed following a comparison of seven coupler sizes (P = 0.066). The mean coupler size used during the TMG flap procedure was smaller than that used with the DIEP (2.4 mm versus 2.8 mm) (P < 0.001). The mean size was also smaller when double venous anastomoses were required compared to single anastomosis (2.4 mm versus 2.9 mm) (P < 0.001). The double branching was more frequent with the TMG flap (28%) than with the DIEP flap (11%). The coupler size used was smaller for the TMG procedure and when double venous anastomosis was performed. Additionally, anastomotic time was not affected by the flap type or coupler size used or by anastomosis number. © 2014 Wiley Periodicals, Inc.
Optimal propulsive flapping in Stokes flows.
Was, Loïc; Lauga, Eric
2014-03-01
Swimming fish and flying insects use the flapping of fins and wings to generate thrust. In contrast, microscopic organisms typically deform their appendages in a wavelike fashion. Since a flapping motion with two degrees of freedom is able, in theory, to produce net forces from a time-periodic actuation at all Reynolds numbers, we compute in this paper the optimal flapping kinematics of a rigid spheroid in a Stokes flow. The hydrodynamics for the force generation and energetics of the flapping motion is solved exactly. We then compute analytically the gradient of a flapping efficiency in the space of all flapping gaits and employ it to derive numerically the optimal flapping kinematics as a function of the shape of the flapper and the amplitude of the motion. The kinematics of optimal flapping are observed to depend weakly on the flapper shape and are very similar to the figure-eight motion observed in the motion of insect wings. Our results suggest that flapping could be a exploited experimentally as a propulsion mechanism valid across the whole range of Reynolds numbers.
Propeller Flaps: A Literature Review.
Sisti, Andrea; D'Aniello, Carlo; Fortezza, Leonardo; Tassinari, Juri; Cuomo, Roberto; Grimaldi, Luca; Nisi, Giuseppe
2016-01-01
Since their introduction in 1991, propeller flaps are increasingly used as a surgical approach to loss of substance. The aim of this study was to evaluate the indications and to verify the outcomes and the complication rates using this reconstructing technique through a literature review. A search on PubMed was performed using "propeller flap", "fasciocutaneous flap", "local flap" or "pedicled flap" as key words. We selected clinical studies using propeller flaps as a reconstructing technique. We found 119 studies from 1991 to 2015. Overall, 1,315 propeller flaps were reported in 1,242 patients. Most frequent indications included loss of substance following tumor excision, repair of trauma-induced injuries, burn scar contractures, pressure sores and chronic infections. Complications were observed in 281/1242 patients (22.6%) occurring more frequently in the lower limbs (31.8%). Partial flap necrosis and venous congestion were the most frequent complications. The complications' rate was significantly higher in infants (<10 years old) and in the older population (>70 years old) but there was not a significant difference between the sexes. Trend of complication rate has not improved during the last years. Propeller flaps showed a great success rate with low morbidity, quick recovery, good aesthetic outcomes and reduced cost. The quality and volume of the transferred soft tissue, the scar orientation and the possibility of direct donor site closure should be considered in order to avoid complications. Indications for propeller flaps are small- or medium-sized defects located in a well-vascularized area with healthy surrounding tissues. Copyright © 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.
NASA Technical Reports Server (NTRS)
Greenblatt, David
2005-01-01
A wind tunnel investigation was carried out on a semi-span wing model to assess the feasibility of controlling vortices emanating from outboard flaps and tip-flaps by actively varying the degree of boundary layer separation. Separation was varied by means of perturbations produced from segmented zero-efflux oscillatory blowing slots, while estimates of span loadings and vortex sheet strengths were obtained by integrating wing surface pressures. These estimates were used as input to inviscid rollup relations as a means of predicting changes to the vortex characteristics resulting from the perturbations. Surveys of flow in the wake of the outboard and tip-flaps were made using a seven-hole probe, from which the vortex characteristics were directly deduced. Varying the degree of separation had a marked effect on vortex location, strength, tangential velocity, axial velocity and size for both outboard and tip-flaps. Qualitative changes in vortex characteristics were well predicted by the inviscid rollup relations, while the failure to account for viscosity was presumed to be the main reason for observed discrepancies. Introducing perturbations near the outboard flap-edges or on the tip-flap exerted significant control over vortices while producing negligible lift excursions.
Quillot, M; Lodde, J P; Pegorier, O; Reynaud, J P; Cormerais, A
1994-08-01
The authors propose a modification of the classical design of island flaps for cover of pressure sores, applied to gluteus maximus and tensor fascia lata muscles: the hatchet flap. 31 flaps have been used including 13 gluteus maximus superior flaps for sacral pressure sores, 9 gluteal inferior flaps for ischial pressure sores and 9 tensor fascia lata flaps for trochanteric pressure sores. A small partial necrosis and two cases of sepsis were observed in this series, but did not require surgical revision. The authors emphasize the value of this modification of the classical flap design, which preserves an even better musculocutaneous capital in these patients, who are often already multi-operated. The very rapid recovery of patients supports the authors' application of hatchet flaps to the surgery of pressure sores, and suggests the extension to other musculocutaneous flaps in the future.
Lucke-Wold, Brandon; Mendez, Gustavo; Cua, David; Akins, Paul; Gillham, Haley; Ciporen, Jeremy
2018-01-01
High flow orbital apex or middle fossa cerebrospinal fluid (CSF) leaks can be life threatening and complex to repair. These leaks associated with large dural defects are most commonly repaired with an open temporalis muscle patch or free flaps, but these flaps do not always stop the leak. A 65-year-old patient presented two years after orbital exenteration and radiation for squamous cell carcinoma. He developed multi-organism meningitis and pneumocephalus secondary to a large high-flow orbital apex/middle fossa CSF leak. To repair the leak, a combined endoscopic transorbital/endonasal approach with pedicled nasospetal flap and dermis fat graft was used. We describe the unique endoscopic technique that was used to treat the life threatening high flow orbital apex/middle fossa CSF leak. The technique allowed the use of the transposed pedicled flap, which is an alternative to the free flap in controlling CSF leak. Cisternogram post-operatively and clinical exam confirmed resolution of CSF leak. Although a critically ill patient at admission with a modified Rankin scale (MRS) of 5, he was discharged home on continued IV antibiotic therapy with a MRS of 3. Endoscopic evaluation at three months after treatment showed the effectiveness of the flap and he continued to improve clinically. This is the first case to describe a combined endoscopic transorbital and endonasal repair of high flow orbital apex/middle fossa CSF leak with a pedicled nasoseptal flap. These techniques can be utilized during initial reconstruction after orbital exenteration or as a salvage flap.
Tran, Bao Ngoc N; Fadayomi, Ayotunde; Lin, Samuel J; Singhal, Dhruv; Lee, Bernard T
2017-09-01
Two staged tissue expander-implant with acellular dermal matrix (TE/I + ADM) and deep inferior epigastric perforator (DIEP) flap are the most common implant and autologous methods of reconstruction in the U.S. Implant-based techniques are disproportionally more popular, partially due to its presumed cost effectiveness. We performed a comprehensive cost analysis to compare TE/I + ADM and DIEP flap. A comparative cost analysis of TE/I + ADM and DIEP flap was performed. Medicare reimbursement costs for each procedure and their associated complications were calculated. Pooled probabilities of complications including cellulitis, seroma, skin necrosis, implant removal, flap loss, partial flap loss, and fat necrosis, were calculated using published studies from 2010 to 2016. Average actual cost for successful TE/I + ADM and DIEP flap were $13 304.55 and $10 237.13, respectively. Incorporating pooled complication data from published literature resulted in an increase in cost to $13 963.46 for TE/I + ADM and $12 624.29 for DIEP flap. The expected costs for successful TE/I + ADM and DIEP flap were $9700.35 and $8644.23, which are lower than the actual costs. DIEP flap breast reconstruction incurs lower costs compared to TE/I + ADM. These costs are lower at baseline and when additional costs from pooled complications are incorporated. © 2017 Wiley Periodicals, Inc.
[Aesthetic effect of wound repair with flaps].
Tan, Qian; Zhou, Hong-Reng; Wang, Shu-Qin; Zheng, Dong-Feng; Xu, Peng; Wu, Jie; Ge, Hua-Qiang; Lin, Yue; Yan, Xin
2012-08-01
To investigate the aesthetic effect of wound repair with flaps. One thousand nine hundred and ninety-six patients with 2082 wounds hospitalized from January 2004 to December 2011. These wounds included 503 deep burn wounds, 268 pressure sores, 392 soft tissue defects caused by trauma, 479 soft tissue defects due to resection of skin cancer and mole removal, 314 soft tissue defects caused by scar excision, and 126 other wounds. Wound area ranged from 1.5 cm x 1.0 cm to 30.0 cm x 22.0 cm. Sliding flaps, expanded flaps, pedicle flaps, and free flaps were used to repair the wounds in accordance with the principle and timing of wound repair with flaps. Five flaps showed venous congestion within 48 hours post-operation, 2 flaps of them improved after local massage. One flap survived after local heparin wet packing and venous bloodletting. One flap survived after emergency surgical embolectomy and bridging with saphenous vein graft. One flap showed partial necrosis and healed after skin grafting. The other flaps survived well. One thousand three hundred and twenty-one patients were followed up for 3 months to 2 years, and flaps of them were satisfactory in shape, color, and elasticity, similar to that of normal skin. Some patients underwent scar revision later with good results. Application of suitable flaps in wound repair will result in quick wound healing, good function recovery, and satisfactory aesthetic effect.
Ademola, Samuel A; Michael, Afieharo I; Oladeji, Femi J; Mbaya, Kefas M; Oyewole, O
2015-01-01
Reverse sural artery fasciocutaneous flap has become a workhorse for the reconstruction of distal leg soft tissue defects. When its use is not feasible, perforator-based propeller flap offers a better, easier, faster, and cheaper alternative to free flap. We present our experience with two men both aged 34 years who sustained Gustilo 3B injuries from gunshot. The donor area for reversed sural artery flap was involved in the injuries. They had early debridement, external fixation, and wound coverage with perforator-based propeller flaps. The donor sites were covered with skin graft. All flaps survived. There were minor wound edge ulcers due to the pressure of positioning that did not affect flap survival and the ulcers healed with conservative management. Perforator-based propeller flap is a versatile armamentarium for reconstruction of soft tissue defects of the distal leg in resource-constrained settings, especially when the donor area for a reverse flow sural flap artery is involved in the injury.
Ip, F. K.
2005-01-01
To compare the outcomes of gluteal fasciocutaneous rotational flaps and myocutaneous flaps in the treatment of sacral sores, together with a review of surgical complications in two matched cohorts. Thirty-eight patients (18 gluteal fasciocutaneous rotational flaps and 20 myocutaneous flaps) were reviewed retrospectively at a mean follow-up of 58 weeks. The rate of healing of the sore, the sore healing time, and the incidence of surgical complications, together with rate of recurrence, were obtained by chart review. Treatment groups were matched by patient characteristics, operative time and blood loss. The rate of healing of the sore, sore healing time and complication rate were comparable in the two groups but the rate of recurrence was lower to a statistically significant extent in myocutaneous flap patients. The authors suggest that both methods are comparable, good and safe in treating sacral sores; myocutaneous flaps are more durable. PMID:16333656
Can, Anil; Orgill, Dennis P; Dietmar Ulrich, J O; Mureau, Marc A M
2014-12-01
Because the vascular anatomy of the trapezius flap is highly variable, choosing the most appropriate flap type and design is essential to optimize outcomes and minimize postoperative complications. The aim of this study was to develop a surgical treatment algorithm for trapezius flap transfers. The medical files of all consecutive patients with a myocutaneous trapezius flap reconstruction of the head, neck, and upper back area treated at three different university medical centers between July 2001 and November 2012 were reviewed. There were 43 consecutive flaps performed in 38 patients with a mean follow-up time of 15 months (range, 1-48 months). Eleven patients had a mentosternal burn scar contracture (12 flaps), 12 patients (13 flaps) presented with cancer, and 15 patients (18 flaps) were suffering from chronic wounds due to failed previous reconstruction (n = 6), osteoradionecrosis (n = 1), chronic infection (n = 3), bronchopleural fistula (n = 3), and pressure sores (n = 2). The mean defect size was 152 cm(2). Sixteen flaps were based on the superficial cervical artery (SCA; type 2), 16 were based on the dorsal scapular artery (DSA; type 3), one was based on the intercostal arteries (type 4), and 10 flaps were based on both the DSA and SCA. Recipient-site complications requiring reoperation occurred in 16.3%, including one total flap failure (2.6%). The trapezius myocutaneous flap is a valuable option to reconstruct various head and neck and upper back defects. Based on our data, a surgical treatment algorithm was developed in an attempt to reduce variation in care and improve clinical outcomes. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Kim, Chae Min; Yun, In Sik; Lee, Dong Won; Lew, Dae Hyun; Rah, Dong Kyun; Lee, Won Jai
2014-07-01
Reconstruction of ischial pressure sore defects is challenging due to extensive bursas and high recurrence rates. In this study, we simultaneously applied a muscle flap that covered the exposed ischium and large bursa with sufficient muscular volume and a profunda femoris artery perforator fasciocutaneous flap for the management of ischial pressure sores. We retrospectively analyzed data from 14 patients (16 ischial sores) whose ischial defects had been reconstructed using both a profunda femoris artery perforator flap and a muscle flap between January 2006 and February 2014. We compared patient characteristics, operative procedure, and clinical course. All flaps survived the entire follow-up period. Seven patients (50%) had a history of surgery at the site of the ischial pressure sore. The mean age of the patients included was 52.8 years (range, 18-85 years). The mean follow-up period was 27.9 months (range, 3-57 months). In two patients, a biceps femoris muscle flap was used, while a gracilis muscle flap was used in the remaining patients. In four cases (25%), wound dehiscence occurred, but healed without further complication after resuturing. Additionally, congestion occurred in one case (6%), but resolved with conservative treatment. Among 16 cases, there was only one (6%) recurrence at 34 months. The combination of a profunda femoris artery perforator fasciocutaneous flap and muscle flap for the treatment of ischial pressure sores provided pliability, adequate bulkiness and few long-term complications. Therefore, this may be used as an alternative treatment method for ischial pressure sores.
Kim, Chae Min; Yun, In Sik; Lee, Dong Won; Lew, Dae Hyun; Rah, Dong Kyun
2014-01-01
Background Reconstruction of ischial pressure sore defects is challenging due to extensive bursas and high recurrence rates. In this study, we simultaneously applied a muscle flap that covered the exposed ischium and large bursa with sufficient muscular volume and a profunda femoris artery perforator fasciocutaneous flap for the management of ischial pressure sores. Methods We retrospectively analyzed data from 14 patients (16 ischial sores) whose ischial defects had been reconstructed using both a profunda femoris artery perforator flap and a muscle flap between January 2006 and February 2014. We compared patient characteristics, operative procedure, and clinical course. Results All flaps survived the entire follow-up period. Seven patients (50%) had a history of surgery at the site of the ischial pressure sore. The mean age of the patients included was 52.8 years (range, 18-85 years). The mean follow-up period was 27.9 months (range, 3-57 months). In two patients, a biceps femoris muscle flap was used, while a gracilis muscle flap was used in the remaining patients. In four cases (25%), wound dehiscence occurred, but healed without further complication after resuturing. Additionally, congestion occurred in one case (6%), but resolved with conservative treatment. Among 16 cases, there was only one (6%) recurrence at 34 months. Conclusions The combination of a profunda femoris artery perforator fasciocutaneous flap and muscle flap for the treatment of ischial pressure sores provided pliability, adequate bulkiness and few long-term complications. Therefore, this may be used as an alternative treatment method for ischial pressure sores. PMID:25075362
Innocenti, M; Cardin-Langlois, E; Menichini, G; Baldrighi, C
2014-02-01
Soft tissue defects involving the anterior aspect of the knee are a frequent finding in a number of pathological conditions. The aim of this article is to describe a new pedicled flap consisting of a conventional medial gastrocnaemius muscle flap associated with a propeller flap based on a perforator of the medial sural artery. Five males ranging in age between 26 and 72 years underwent a reconstruction of the soft tissue of the knee by means of the described procedure. Three patients sustained complex tissue loss subsequent to high-energy trauma; two losses were due to septic complications after elective knee surgery. Four flaps survived allowing adequate proximal tibial metaphysis and patella coverage. One patient underwent early above-the-knee amputation due to life-threatening septicaemia. The described chimaera flap consists of a medial gastrocnaemius flap with a skin paddle that is elevated on a perforator of the medial sural artery and then rotated according to the propeller flaps' principles. It provides effective coverage of large soft tissue defects of the knee. In the authors' experience, the propeller flap portion proved to be particularly useful to cover the patella, while the muscle flap was used to cover the proximal metaphysis of the tibia and fill the dead space if present. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
The use of silicone sheet to improve buccal fat pad healing in palatal reconstruction.
Robiony, Massimo
2010-10-01
The author presents a new method involving the use of a silicone sheet to achieve an improved, faster healing of pedicled buccal fat pad flaps used in palatal reconstructions. This method was applied in 3 patients with excellent final results. The procedure is quick and easy to implement, and it efficiently improves the healing of buccal fat pad used in palatal reconstruction surgery. Copyright 2010 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Koul, Ashok R; Nahar, Sushil; Prabhu, Jagdish; Kale, Subhash M; Kumar, Praveen H P
2011-09-01
A soft tissue defect requiring flap cover which is longer than that provided by the conventional "long" free flaps like latissimus dorsi (LD) and anterolateral thigh (ALT) flap is a challenging problem. Often, in such a situation, a combination of flaps is required. Over the last 3 years, we have managed nine such defects successfully with a free "Boomerang-shaped" Extended Rectus Abdominis Myocutaneous (BERAM) flap. This flap is the slightly modified and "free" version of a similar flap described by Ian Taylor in 1983. This is a retrospective study of patients who underwent free BERAM flap reconstruction of soft tissue defects of extremity over the last 3 years. We also did a clinical study on 30 volunteers to compare the length of flap available using our design of BERAM flap with the maximum available flap length of LD and ALT flaps, using standard markings. Our clinical experience of nine cases combined with the results of our clinical study has confirmed that our design of BERAM flap consistently provides a flap length which is 32.6% longer than the standard LD flap and 42.2% longer than the standard ALT flap in adults. The difference is even more marked in children. The BERAM flap is consistently reliable as long as the distal end is not extended beyond the mid-axillary line. BERAM flap is simple in design, easy to harvest, reliable and provides the longest possible free skin/myocutaneous flap in the body. It is a useful new alternative for covering long soft tissue defects in the limbs.
Pedicled Extranasal Flaps in Skull Base Reconstruction
Kim, Grace G.; Hang, Anna X.; Mitchell, Candace; Zanation, Adam M.
2013-01-01
Cerebrospinal fluid (CSF) leaks most commonly arise during or after skull base surgery, although they occasionally present spontaneously. Recent advances in the repair of CSF leaks have enabled endoscopic endonasal surgery to become the preferred option for management of skull base pathology. Small defects (<1cm) can be repaired by multilayered free grafts. For large defects (>3cm), pedicled vascular flaps are the repair method of choice, resulting in much lower rates of postoperative CSF leaks. The pedicled nasoseptal flap (NSF) constitutes the primary reconstructive option for the vast majority of skull base defects. It has a large area of potential coverage and high rates of success. However, preoperative planning is required to avoid sacrificing the NSF during resection. In cases where the NSF is unavailable, often due to tumor involvement of the septum or previous resection removing or compromising the flap, other flaps may be considered. These flaps include intranasal options—inferior turbinate (IT) or middle turbinate (MT) flaps—as well as regional pedicled flaps: pericranial flap (PCF), temporoparietal fascial flap (TPFF), or palatal flap (PF). More recently, novel alternatives such as the pedicled facial buccinator flap (FAB) and the pedicled occipital galeopericranial flap (OGP) have been added to the arsenal of options for skull base reconstruction. Characteristics of and appropriate uses for each flap are described. PMID:23257554
Seyhan, Tamer
2009-03-01
A versatile musculocutan flap from the radix nasi region, the radix nasi island flap, is described. The flap has an axial blood supply derived from the dorsal nasal branch of the ophthalmic artery which is anastomosed to the terminal branch of the facial artery. The flap includes the skin, subcutaneous tissue, and procerus muscle. Ten patients, aged 50 to 86 years, have been reconstructed with this flap for defects in the nose (in 4 cases), midface (in 4 cases) and lower eyelids (in 2 cases). The mean flap size was 17 x 23 mm (range: 15 x 20 to 20 x 27 mm). All flaps fully survived. Additional complications and morbidity were not observed. The donor sites were closed a primarily closure in all cases. Follow-up ranged from 3 to 12 months (mean: 8.2 months). The radix nasi flap is a safe flap, has minimal donor site morbidity, and is especially suited for nasal and midface reconstruction in terms of attaining a suitable color and thickness.
Koul, Ashok R.; Nahar, Sushil; Prabhu, Jagdish; Kale, Subhash M.; Kumar, Praveen H. P.
2011-01-01
Background: A soft tissue defect requiring flap cover which is longer than that provided by the conventional “long” free flaps like latissimus dorsi (LD) and anterolateral thigh (ALT) flap is a challenging problem. Often, in such a situation, a combination of flaps is required. Over the last 3 years, we have managed nine such defects successfully with a free “Boomerang-shaped” Extended Rectus Abdominis Myocutaneous (BERAM) flap. This flap is the slightly modified and “free” version of a similar flap described by Ian Taylor in 1983. Materials and Methods: This is a retrospective study of patients who underwent free BERAM flap reconstruction of soft tissue defects of extremity over the last 3 years. We also did a clinical study on 30 volunteers to compare the length of flap available using our design of BERAM flap with the maximum available flap length of LD and ALT flaps, using standard markings. Results: Our clinical experience of nine cases combined with the results of our clinical study has confirmed that our design of BERAM flap consistently provides a flap length which is 32.6% longer than the standard LD flap and 42.2% longer than the standard ALT flap in adults. The difference is even more marked in children. The BERAM flap is consistently reliable as long as the distal end is not extended beyond the mid-axillary line. Conclusion: BERAM flap is simple in design, easy to harvest, reliable and provides the longest possible free skin/myocutaneous flap in the body. It is a useful new alternative for covering long soft tissue defects in the limbs. PMID:22279271
Yagi, Shunjiro; Toriyama, Kazuhiro; Takanari, Keisuke; Fujimoto, Yasushi; Nishio, Naoki; Fujii, Masazumi; Saito, Kiyoshi; Takahashi, Masakatsu; Kamei, Yuzuru
2016-01-01
Background: Although we have seen tremendous advancement in microsurgery over the last 2 decades and free tissue transfer has become standard for head and neck reconstruction, surgeons still struggle to prevent postoperative complications. We examined the relationship between body mass index (BMI) and postoperative complications in patients undergoing rectus abdominis free flap transfer after anterolateral craniofacial resection. Methods: This was a retrospective review of reconstructive surgery using rectus abdominis musculocutaneous free flap in patients with locally advanced maxillary sinus carcinoma from 2003 to 2014 (n = 35, 27 men and 8 women; average age, 60.9 ± 7.8 years). All patients underwent craniofacial reconstruction after anterior and middle cranial fossa skull base resection and maxillectomy (class IV, subtype a) with palatal resection. Patients were categorized based on sex, BMI, and other parameters. Results: Recipient-site infection occurred in 11 patients (31.4%), cerebrospinal fluid leakage in 6 (17.1%), partial flap necrosis in 2 (5.7%), total flap necrosis in 1 (2.9%), and facial fistula in 4 (11.4%). Women showed partial flap necrosis significantly more frequently (P = 0.047), probably owing to poor vascular supply of the subcutaneous fat layer. Patients with low BMI (<20 kg/m2) showed recipient-site infection (P = 0.02) and facial fistula (P = 0.01) significantly more frequently owing to insufficient tissue volume and poor vascular supply. Conclusion: Postoperative recipient-site infection and facial fistula occurred mainly in low-BMI patients. Surgeons should take care to achieve sufficient donor tissue on low-BMI patients. Using a prosthetic obturator in low-BMI patients for craniofacial reconstruction can be a good alternative option to reduce postoperative complications due to insufficient donor tissue volume. PMID:27257566
Cost-effectiveness of monitoring free flaps.
Subramaniam, Shiva; Sharp, David; Jardim, Christopher; Batstone, Martin D
2016-06-01
Methods of free flap monitoring have become more sophisticated and expensive. This study aims to determine the cost of free flap monitoring and examine its cost effectiveness. We examined a group of patients who had had free flaps to the head and neck over a two-year period, and combined these results with costs obtained from business managers and staff. There were 132 free flaps with a success rate of 99%. The cost of monitoring was Aus $193/flap. Clinical monitoring during this time period cost Aus$25 476 and did not lead to the salvage of any free flaps. Cost equivalence is reached between monitoring and not monitoring only at a failure rate of 15.8%. This is to our knowledge the first study to calculate the cost of clinical monitoring of free flaps, and to examine its cost-effectiveness. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. All rights reserved.
Rotation Flaps-Principles and Locations.
LoPiccolo, Matteo C
2015-10-01
The rotation flap is a classic method of tissue rearrangement. It is a simple yet effective tool for recruiting tissue from areas of laxity and redirecting vectors of tension to reconstruct wounds not amenable to primary closure. This article presents the basic design principles and specific applications of the rotation flap in dermatologic surgery. A Medline search of articles describing rotation flaps published prior to April 1, 2015 was performed, and several prominent texts in dermatologic surgery were reviewed. Information gathered from the above sources is combined with the clinical experience of the author and editors to present surgeons with a guide for planning and executing various rotation flaps. Mastering the technique of the rotation flap will allow a surgeon to repair a wide variety of cutaneous defects.
Power performance optimization and loads alleviation with active flaps using individual flap control
NASA Astrophysics Data System (ADS)
Pettas, Vasilis; Barlas, Thanasis; Gertz, Drew; Madsen, Helge A.
2016-09-01
The present article investigates the potential of Active Trailing Edge Flaps (ATEF) in terms of increase in annual energy production (AEP) as well as reduction of fatigue loads. The basis for this study is the DTU 10 MW Reference Wind Turbine (RWT) simulated using the aeroelastic code HAWC2. In an industrial-oriented manner the baseline rotor is upscaled by 5% and the ATEFs are implemented in the outer 30% of the blades. The flap system is kept simple and robust with a single flap section and control with wind speed, rotor azimuth, root bending moments and angle of attack in flap's mid-section being the sensor inputs. The AEP is increased due to the upscaling but also further due to the flap system while the fatigue loads in components of interest (blade, tower, nacelle and main bearing) are reduced close to the level of the original turbine. The aim of this study is to demonstrate a simple and applicable method that can be a technology enabler for rotor upscaling and lowering cost of energy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sanchez-Conejo-Mir, J.; Bueno Montes, J.; Moreno Gimenez, J.C.
1985-09-01
The bilobed flap is a simple reconstructive technique principally used to correct substantial defects in the facial region. The authors present their experience with this local flap in the difficult plantar area, with excellent short-term functional results. They describe the special characteristics of the bilobed flap in this zone, and comment on its indications and possible complications.
NASA Astrophysics Data System (ADS)
Xie, Lingwang; Zhang, Xingwei; Luo, Pan; Huang, Panpan
2017-10-01
The optimization designs and dynamic analysis on the driving mechanism of flapping-wing air vehicles on base of flapping trajectory patterns is carried out in this study. Three different driving mechanisms which are spatial double crank-rocker, plane five-bar and gear-double slider, are systematically optimized and analysed by using the Mat lab and Adams software. After a series debugging on the parameter, the comparatively ideal flapping trajectories are obtained by the simulation of Adams. Present results indicate that different drive mechanisms output different flapping trajectories and have their unique characteristic. The spatial double crank-rocker mechanism can only output the arc flapping trajectory and it has the advantages of small volume, high flexibility and efficient space utilization. Both planar five-bar mechanism and gear-double slider mechanism can output the oval, figure of eight and double eight flapping trajectories. Nevertheless, the gear-double slider mechanism has the advantage of convenient parameter setting and better performance in output double eight flapping trajectory. This study can provide theoretical basis and helpful reference for the design of the drive mechanisms of flapping-wing air vehicles with different output flapping trajectories.
Skin flaps and grafts - self-care
... Free flap - self-care; Skin autografting - self-care; Pressure ulcer skin flap self-care; Burns skin flap self- ... skin infection Surgery for skin cancer Venous ulcers , pressure ulcers , or diabetic ulcers that DO NOT heal After ...
Cordova, Adriana; Toia, Francesca; D'Arpa, Salvatore; Giunta, Gabriele; Moschella, Francesco
2015-03-01
Lingual flaps provide ideal mucosal coverage for intraoral defects but traditionally require two surgical stages. The authors present an axial mucosal propeller flap for single-stage intraoral reconstruction. The flap includes the mucosa of the lateral side of the tongue, islanded on the deep lingual vessels. Between 2011 and 2013, 23 patients underwent intraoral mucosal reconstruction with a deep lingual artery axial propeller flap after cancer resection in the cheek (n = 16), floor of the mouth (n = 2), retromolar trigone (n = 2), hard palate (n = 2), and soft palate (n = 1). Mean defect size was 19.5 cm. Preoperative and postoperative intraoral function was evaluated with the Functional Intraoral Glasgow Scale. The authors always achieved one-stage reconstruction with primary donor-site closure. The only complications were an infection treated conservatively and a late oronasal fistula caused by radiotherapy. All patients resumed an oral diet after 1 week and none required surgical revision. Mean 12-month postoperative Functional Intraoral Glasgow Scale score was better than the preoperative score (13.5 versus 12.8). The deep lingual artery axial propeller flap combines the advantages of the traditional lingual flap (i.e., reliable axial vascularization and like-with-like reconstruction) with those of a propeller flap (i.e., one-stage transfer of like tissue and extreme mobility) and has wider indications than a conventional lingual flap. The technique is fast and has low morbidity and good functional results, and the authors recommend it as a first-choice technique to reconstruct moderate to large intraoral defects. Therapeutic, IV.
NASA Astrophysics Data System (ADS)
Ko, Seung-Hee; Bae, Jae-Sung; Rho, Jin-Ho
2014-07-01
The discontinuous contour of a wing with conventional flaps diminishes the aerodynamic performance of an aircraft. A wing with a continuous contour does not experience extreme flow stream fluctuations during flight, and consequently has good aerodynamic characteristics. In this study, a morphing flap using shape memory alloy actuators is proposed, designed and fabricated, and its aerodynamic characteristics are investigated using aerodynamic analyses and wind tunnel tests. The ribs of the morphing flap are designed and fabricated with multiple elements joined together in a way that allows relative rotations of adjacent elements and forms a smooth contour of the morphing flap. The aerodynamic analyses of this multiple-element morphing-flap wing are performed using XFLR pro; its aerodynamic performance is compared with that of a mechanical-flap wing, and is measured through wind-tunnel tests.
NASA Technical Reports Server (NTRS)
Platt, Robert C
1936-01-01
This report presents the results of wind tunnel tests of a wing in combination with each of three sizes of Fowler flap. The purpose of the investigation was to determine the aerodynamic characteristics as affected by flap chord and position, the air loads on the flaps, and the effect of flaps on the downwash.
Perforator Peroneal Artery Flap for Tongue Reconstruction.
Chauhan, Shubhra; Chavre, Sachin; Chandrashekar, Naveen Hedne; B S, Naveen
2017-03-01
Reconstruction has evolved long way from primary closure to flaps. As time evolved, better understanding of vascularity of flap has led to the development of innovative reconstructive techniques. These flaps can be raised from various parts of the body for reconstruction and have shown least donor site morbidity. We use one such peroneal artery perforator flap for tongue reconstruction with advantage of thin pliable flap, minimal donor site morbidity and hidden scar. Our patient 57yrs old lady underwent wide local excision with selective neck dissection. Perforators are marked about 10 and 15 cm inferiorly from the fibular head using hand held Doppler. Leg is positioned in such a way to give better exposure during dissection of the flap and flap is harvested under a tourniquet with pressure kept 350 mm Hg. The perforator is kept at the eccentric location, so as to gain length of the pedicle. Skin incison is placed over the peroneal muscle and deepened unto the deep facia, then the dissection is continued over the muscle and the perforator arising from the lateral septum. The proximal perforator about 10 cm from the fibular head is a constant perforator and bigger one, which is traced up to the peroneal vessel. We could get a 6 cm of pedicle length. Finally the flap is islanded on this perforator and the pedicle is ligated and flap harvested. Anastamosis was done to the ipsilateral side to facial vessels. The donor site is closed primarily and in the upper half one can harvest 5 cm width flap without requiring a skin graft along with a length of 8 to 12 cm. Various local and free flap has been used for reconstruction of partial tongue defects with its obvious donor site problems, like less pliable skin and not so adequate tissue from local flaps and sacrificing a important artery as in radial forearm flap serves as the work horse in reconstruction of partial tongue defects, Concept of super microsurgery was popularized by Japanese in 1980s and the concept of
Lower Extremity Reconstruction with Free Gracilis Flaps
Nicoson, Michael C; Parikh, Rajiv P; Tung, Thomas H
2017-01-01
Background There have been significant advancements in lower extremity reconstruction over the last several decades, and the plastic surgeon’s armamentarium has grown to include free muscle and fasciocutaneous flaps along with local perforator and propeller flaps. While we have found a use for a variety of techniques for lower extremity reconstruction, the free gracilis has been our workhorse flap due to the ease of harvest, reliability, and low donor site morbidity. Methods This is a retrospective review of a single surgeon’s series of free gracilis flaps utilized for lower extremity reconstruction. Demographic information, comorbidities, outcomes and secondary procedures were analyzed. Results We identified 24 free gracilis flaps. The duration from injury to free flap coverage was 7 days or less in 6 patients, 8–30 days in 11 patients, 31–90 days in 4 patients, and > 90 days in 3 patients. There were 22 (92%) successful flaps and an overall limb salvage rate of 92%. There was one partial flap loss. Two flaps underwent incision and drainage in the operating room for infection. Two patients developed donor site hematomas. Four patients underwent secondary procedures for contouring. Our subset of pediatric patients had 100% flap survival and no secondary procedures at a mean 30 month follow up. Conclusions This study demonstrates the utility of the free gracilis flap in reconstruction of small to medium sized defects of the lower extremity. This flap has a high success rate and low donor site morbidity. Atrophy of the denervated muscle over time allows for good shoe fit, often obviating the need for secondary contouring procedures. PMID:28024305
Leclère, Franck Marie; Casoli, Vincent
2015-01-01
Lower extremity defects may account for 14.6% of the approximately 117 million visits to emergency departments in the U. S. in 2007. In this article, we present a reconstruction of a traumatic plantar foot defect with a medial triceps brachii (MTB) free flap. A 53-year-old man sustained an accidental gunshot wound to the right foot. The patient was admitted after the failure of a sural flap procedure performed in another hospital. He presented with a soft-tissue defect with calcaneal exposition and osteomyelitis. The defect was reconstructed with a MTB free flap anastomosed to his dorsalis pedis vessels. Flap raising time was 52 min. There were no intraoperative complications. The total flap surface was 38.5 cm². The pedicle length was 3 cm. The diameters of the artery and vein of the flap pedicle were 1.1 mm and 1.4 mm, respectively. Ischemia time was 28 min. His donor site healed uneventfully without any morbidity, and the scar was well concealed. The flaps survived and there was no partial flap necrosis. A split-thickness skin graft was performed 12 days postoperatively. Two months later, he had a completely healed wound with no contour abnormality. The total follow-up was 24 months. The patient was able to walk normally. MTB free flap appears to be an excellent option for plantar foot defects in patients with preserved vascularization of the foot. Due to the anatomical shape of the flap, the position of its pedicle, and the moldability of the muscle, we predict that the use of the MTB free flap will grow and develop rapidly for reconstruction of ankle and foot defects.
Kim, Youn Hwan; Kim, Sang Wha; Kim, Jeong Tae; Kim, Chang Yeon
2013-06-01
Tensor fascia lata (TFL) musculocutaneous flaps often require a donor site graft when harvesting a large flap. However, a major drawback is that it also sacrifices the muscle. To overcome this disadvantage, we designed a TFL perforator-based island flap that was harvested from a site near the defect and involved transposition within 90 degrees without full isolation of the pedicles. We performed procedures on 17 musculocutaneous flaps and 23 perforator-based island flaps, and compared the outcomes of these surgeries. The overall complication rate was 27.5% (11 regions). There were 7 complications related to the musculocutaneous flaps and 4 complications related to the perforator flaps. Although there were no statistical differences between those groups, lower complication rates were associated with procedures involving perforator flaps. The TFL perforator procedure is a simple and fast operation that avoids sacrificing muscle. This decreases complication rates compared to true perforator flap techniques that require dissection around the perforator or pedicle.
Tarantino, Mary E; Bilotti, Katharina; Huang, Ji; Delaney, Sarah
2015-08-21
Flap endonuclease 1 (FEN1) is a structure-specific nuclease responsible for removing 5'-flaps formed during Okazaki fragment maturation and long patch base excision repair. In this work, we use rapid quench flow techniques to examine the rates of 5'-flap removal on DNA substrates of varying length and sequence. Of particular interest are flaps containing trinucleotide repeats (TNR), which have been proposed to affect FEN1 activity and cause genetic instability. We report that FEN1 processes substrates containing flaps of 30 nucleotides or fewer at comparable single-turnover rates. However, for flaps longer than 30 nucleotides, FEN1 kinetically discriminates substrates based on flap length and flap sequence. In particular, FEN1 removes flaps containing TNR sequences at a rate slower than mixed sequence flaps of the same length. Furthermore, multiple-turnover kinetic analysis reveals that the rate-determining step of FEN1 switches as a function of flap length from product release to chemistry (or a step prior to chemistry). These results provide a kinetic perspective on the role of FEN1 in DNA replication and repair and contribute to our understanding of FEN1 in mediating genetic instability of TNR sequences. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.
Degner, D A; Walshaw, R; Arnoczky, S P; Smith, R J; Patterson, J S; Degner, L A; Hamaide, A; Rosenstein, D
1996-01-01
This study evaluates the cranial rectus abdominus muscle pedicle flap as the sole blood supply for the caudal superficial epigastric skin flap. This flap was composed of a cranially based rectus abdominus muscle pedicle flap that was attached to the caudal superficial epigastric island skin flap (including mammary glands 2 to 5) via the pudendoepigastric trunk. Selective angiography of the cranial epigastric artery in eight cadaver dogs proved that the arterial vasculature in the cranial rectus abdominus was contiguous with that in the caudal superficial epigastric skin flap. In the live dog study, three of six of the flaps failed because of venous insufficiency. Necrosis of mammary gland 2 occurred in two of six flaps. One of six flaps survived with the exception of the cranial most aspect of mammary gland 2. Angiography of the cranial epigastric artery proved that arterial blood supply to these flaps was intact. Histological evaluation of the failed flaps showed full-thickness necrosis of the skin and subcutaneous tissues, the presence of severe congestion, and venous thrombosis. Retrograde venous blood flow through the flap was inconsistent, and hence resulted in failure of this myocutaneous flap. Use of this flap for clinical wound reconstruction cannot be recommended.
14 CFR 23.697 - Wing flap controls.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Wing flap controls. 23.697 Section 23.697... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.697 Wing flap controls. (a) Each wing flap control must be designed so that, when the flap...
14 CFR 23.697 - Wing flap controls.
Code of Federal Regulations, 2011 CFR
2011-01-01
... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.697 Wing flap controls. (a) Each wing flap control must be designed so that, when the flap... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Wing flap controls. 23.697 Section 23.697...
14 CFR 23.697 - Wing flap controls.
Code of Federal Regulations, 2012 CFR
2012-01-01
... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.697 Wing flap controls. (a) Each wing flap control must be designed so that, when the flap... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Wing flap controls. 23.697 Section 23.697...
14 CFR 23.697 - Wing flap controls.
Code of Federal Regulations, 2014 CFR
2014-01-01
... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.697 Wing flap controls. (a) Each wing flap control must be designed so that, when the flap... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Wing flap controls. 23.697 Section 23.697...
14 CFR 23.697 - Wing flap controls.
Code of Federal Regulations, 2010 CFR
2010-01-01
... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.697 Wing flap controls. (a) Each wing flap control must be designed so that, when the flap... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Wing flap controls. 23.697 Section 23.697...
Propeller thoracodorsal artery perforator flap for breast reconstruction.
Angrigiani, Claudio; Rancati, Alberto; Escudero, Ezequiel; Artero, Guillermo; Gercovich, Gustavo; Deza, Ernesto Gil
2014-08-01
The thoracodorsal artery perforator (TDAP) flap has been described for breast reconstruction. This flap requires intramuscular dissection of the pedicle. A modification of the conventional TDAP surgical technique for breast reconstruction is described, utilizing instead a propeller TDAP flap. The authors present their clinical experience with the propeller TDAP flap in breast reconstruction alone or in combination with expanders or permanent implants. From January 2009 to February 2013, sixteen patients had breast reconstruction utilizing a propeller TDAP flap. Retrospective analysis of patient characteristics, clinical indications, procedure and outcomes were performed. The follow-up period ranged from 4 to 48 months. Sixteen patients had breast reconstruction using a TDAP flap with or without simultaneous insertion of an expander or implant. All flaps survived, while two cases required minimal resection due to distal flap necrosis, healing by second intention. There were not donor-site seromas, while minimal wound dehiscence was detected in two cases. The propeller TDAP flap appears to be safe and effective for breast reconstruction, resulting in minimal donor site morbidity. The use of this propeller flap emerges as a true alternative to the traditional TDAP flap.
Free flap reconstruction for diabetic foot limb salvage.
Sato, Tomoya; Yana, Yuichiro; Ichioka, Shigeru
2017-12-01
Although free flap is gaining popularity for the reconstruction of diabetic foot ulcers, it is unclear whether free flap reconstruction increases the chances of postoperative independent ambulation. The aim of this study is to evaluate the relationship between free flap success and postoperative ambulation. This study reviewed 23 cases of free flap reconstruction for diabetic foot ulcers between January 2007 and March 2014. Free rectus abdominis, latissimus dorsi, and anterolateral thigh flaps were used in ten, eight, and five patients, respectively. A comparison was made between free flap success and postoperative independent ambulation using Fisher's exact test. Two patients developed congestive heart failure with fatal consequences within 14 days postoperatively, resulting in an in-hospital mortality rate of 8.7%. Five patients lost their flaps (21.7%). Of the 16 patients who had flap success, 12 achieved independent ambulation. Five patients with flap loss did not achieve independent ambulation, except one patient who underwent secondary flap reconstruction using a distally based sural flap. Fisher's exact test revealed that independent ambulation was associated with free flap success (p = 0.047). The present study indicates that free flap reconstruction may increase the possibility of independent ambulation for patients with extensive tissue defects due to diabetic ulcers. Intermediate limb salvage rates and independent ambulation rates were favourable in patients with successful reconstruction. The use of foot orthoses and a team approach with pedorthists were effective to prevent recurrence.
Single-stage interpolation flaps in facial reconstruction.
Hollmig, S Tyler; Leach, Brian C; Cook, Joel
2014-09-01
Relatively deep and complex surgical defects, particularly when adjacent to or involving free margins, present significant reconstructive challenges. When the use of local flaps is precluded by native anatomic restrictions, interpolation flaps may be modified to address these difficult wounds in a single operative session. To provide a framework to approach difficult soft tissue defects arising near or involving free margins and to demonstrate appropriate design and execution of single-stage interpolation flaps for reconstruction of these wounds. Examination of our utilization of these flaps based on an anatomic region and surgical approach. A region-based demonstration of flap conceptualization, design, and execution is provided. Tunneled, transposed, and deepithelialized variations of single-stage interpolation flaps provide versatile options for reconstruction of a variety of defects encroaching on or involving free margins. The inherently robust vascularity of these flaps supports importation of necessary tissue bulk while allowing aggressive contouring to restore an intricate native topography. Critical flap design allows access to distant tissue reservoirs and placement of favorable incision lines while preserving the inherent advantages of a single operative procedure.
Ipsilateral pedicled TRAM flaps: the safer alternative?
Clugston, P A; Gingrass, M K; Azurin, D; Fisher, J; Maxwell, G P
2000-01-01
Transverse rectus abdominis myocutaneous (TRAM) flap breast reconstruction has become a commonly performed procedure in the 1990s. The original description of the procedure was that of an ipsilaterally based pedicle procedure. Concerns about potential folding of the pedicle with possible compromise of the vascular supply led many surgeons to prefer the contralateral pedicle. Subsequently, there have been several large clinical series of pedicled TRAM flaps showing a relatively high complication rate related to flap vascularity problems. Partial flap necrosis rates in pedicled TRAM series range from 5 to 44 percent. These findings resulted in many centers favoring free TRAM flap breast reconstruction, despite an increase in resource use and negligible differences in complication rates. Ipsilateral pedicle TRAM flap breast reconstruction is not a commonly reported procedure and is reserved for cases for which scars preclude use of the contralateral pedicle. Simplicity and versatility of flap shaping, improved maintenance of the inframammary fold, and lack of disruption of the natural xiphoid hollow give ipsilateral TRAM flaps further advantages. This study reports on a series of 252 consecutive ipsilateral TRAM flap reconstructions in 190 patients. The majority of patients underwent muscle-sparing procedures with preservation of a medial and a lateral strip of rectus muscle. Immediate reconstruction was done in 104 of the 190 patients. Skin-sparing (69 patients) or skin-reduction procedures (21 patients) were used in 90 of the 104 patients (87 percent) undergoing immediate reconstruction. Complication rates were comparable to those of series reported for contralateral TRAM flaps, except that partial flap necrosis (2.0 percent) was less in this series. Risk factors were analyzed with regard to the most common complications seen in this study. Ipsilateral TRAM flap breast reconstruction is our preferred method, if available, because we believe that it has several
Energy management - The delayed flap approach
NASA Technical Reports Server (NTRS)
Bull, J. S.
1976-01-01
Flight test evaluation of a Delayed Flap approach procedure intended to provide reductions in noise and fuel consumption is underway using the NASA CV-990 test aircraft. Approach is initiated at a high airspeed (240 kt) and in a drag configuration that allows for low thrust. The aircraft is flown along the conventional ILS glide slope. A Fast/Slow message display signals the pilot when to extend approach flaps, landing gear, and land flaps. Implementation of the procedure in commercial service may require the addition of a DME navigation aid co-located with the ILS glide slope transmitter. The Delayed Flap approach saves 250 lb of fuel over the Reduced Flap approach, with a 95 EPNdB noise contour only 43% as large.
Laurent, B; Rouif, M; Giordano, P; Mateu, J
2011-12-01
Vascular complications of the unipedicled TRAM flap pointed out the need for solutions to decrease such occurrences. The flap surgical delay before transfer has been advocated to improve the blood supply but, at the same time, it increases the risk of wound infection at the donor site and imposes a general anesthesia. The DIEP and the free TRAM flap are more complex procedures and need heavy structural resources. Preferential use of the ipsilateral muscular pedicle suggests a lower partial flap necrosis rate. Selective embolization of the deep inferior epigastric arteries prior to surgery realizes an alternative delay and brings a decrease in the vascular complication rate as shown in a study of 40 patients by Scheufler in 2000. We present a series of 69 patients who were reconstructed by means of a delayed pedicled TRAM flap with selective embolization and a predominant use of the ispsilateral pedicle. Sonographic studies performed in 48 patients prior to surgery showed no significative difference in the diameter of the superior epigastic arteries, with or without previous radiotherapy. The mean interval between embolization and surgery was 30 days; the embolization was performed bilateraly in five patients (4 %), and unilaterally in 64 patients (96 %). The mean age of patients was 54 years, radiotherapy was applied in 43 patients (62 %), smoking patients: 11 (16 %), obesity: five (7 %). The ispsilateral pedicled was used in 67 patients (97 %), controlateral pedicle in two patients (3 %). Postoperative flap complications were comprised of partial flap necrosis in two cases (2,9 %), fat necrosis in six cases (8,7 %), impaired wound healing in three cases (4,3 %), abdominal wall weakness in two cases (2,9 %). We compared the present study of ispsilateral delayed pedicled flap to a study from the same authors concerning controlateral pedicled flaps without delay. It has been demonstrated that the complications rate of partial necrosis was divided
Risk Factor Analysis of Freestyle Propeller Flaps.
Paik, Joo Myong; Pyon, Jai-Kyong
2017-01-01
Background Freestyle propeller flaps have been widely used as a reconstructive option for both trunk and extremities. It offers the advantage of "like-with-like" reconstruction with an adjacent tissue with no dissection to the source vessels. However, there is the risk of vascular complications. In the present study, the authors investigated the incidence of vascular complications and their risk factors following freestyle propeller flap in the trunk and extremities. Methods The authors conducted a retrospective review of 50 patients who underwent soft tissue reconstruction of the trunk and the extremities with 55 freestyle propeller flaps from 2004 to 2015. Data regarding patient demographics, surgical details, including the arc of rotation, and flap complications were collected from a prospectively maintained database and analyzed. Results There were 10 flap complications (18.2%), including 7 superficial partial necrosis, 2 full-thickness partial necrosis, and 1 total necrosis from the 55 freestyle propeller flaps harvested. Previous irradiation was a significant risk factor for flap complications and the propeller flap harvested from the extremities showed a significantly higher rate of complications compared with those harvested from the trunk. Complication rates were higher in flaps with the arc of rotation between 150 and 180 degrees with marginal significance compared with flaps with the arc of rotation less than 150 degrees. Conclusions Freestyle propeller flaps proved to be a valid and reliable option for reconstruction of defects in the trunk, while complication rate was quite high in the extremities. A prudent preoperative evaluation and preparation may be necessary before performing this surgical technique in the extremities. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Externally blown flap noise research
NASA Technical Reports Server (NTRS)
Dorsch, R. G.
1974-01-01
The Lewis Research Center cold-flow model externally blown flap (EBF) noise research test program is summarized. Both engine under-the-wing and over-the-wing EBF wing section configurations were studied. Ten large scale and nineteen small scale EBF models were tested. A limited number of forward airspeed effect and flap noise suppression tests were also run. The key results and conclusions drawn from the flap noise tests are summarized and discussed.
14 CFR 25.1511 - Flap extended speed.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Flap extended speed. 25.1511 Section 25... Limitations § 25.1511 Flap extended speed. The established flap extended speed V FE must be established so that it does not exceed the design flap speed V F chosen under §§ 25.335(e) and 25.345, for the...
14 CFR 25.1511 - Flap extended speed.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Flap extended speed. 25.1511 Section 25... Limitations § 25.1511 Flap extended speed. The established flap extended speed V FE must be established so that it does not exceed the design flap speed V F chosen under §§ 25.335(e) and 25.345, for the...
Numajiri, Toshiaki; Nakatsukasa, Katsuhiko; Sakaguchi, Koichi; Taguchi, Tetsuya
2017-01-01
Purpose The pedicled, descending-branch muscle-sparing latissimus dorsi (MSLD) flap has been widely used for breast reconstruction following total mastectomy. However, the superiority of the MSLD flap compared to the conventional latissimus dorsi (CLD) flap in preventing seroma formation has not been demonstrated. This study compares the morbidities related to seroma formation following pedicled MSLD flap and CLD flap breast reconstruction. Methods A total of 15 women who underwent partial mastectomy and immediate partial breast reconstruction with MSLD flaps were compared with 15 women under identical conditions with CLD flap breast reconstruction. The medical records were reviewed for both complications and demographic data. The authors compared morbidity, including donor-site seroma, total volume of drain discharge, indwelling period of drainage, and length of hospital stay following both MSLD flap and CLD flap breast reconstruction. Results The demographic data of the 2 groups were not significantly different. Donor-site seroma occurred in 2 MSLD patients (13.3%) and in 6 CLD patients (40.0%). The total volume of the drain discharge and the indwelling period of drainage at donor site were significantly lower in the MSLD group. The length of hospital stay was significantly shorter (by approximately a day and a half) for the MSLD group. Conclusion The MSLD flap, with its low complication rate and associated minimal functional and aesthetic deficits at the donor site, may be a useful option for small breast reconstruction if earlier discharge from hospital is demanded. PMID:28932726
Sowa, Yoshihiro; Numajiri, Toshiaki; Nakatsukasa, Katsuhiko; Sakaguchi, Koichi; Taguchi, Tetsuya
2017-09-01
The pedicled, descending-branch muscle-sparing latissimus dorsi (MSLD) flap has been widely used for breast reconstruction following total mastectomy. However, the superiority of the MSLD flap compared to the conventional latissimus dorsi (CLD) flap in preventing seroma formation has not been demonstrated. This study compares the morbidities related to seroma formation following pedicled MSLD flap and CLD flap breast reconstruction. A total of 15 women who underwent partial mastectomy and immediate partial breast reconstruction with MSLD flaps were compared with 15 women under identical conditions with CLD flap breast reconstruction. The medical records were reviewed for both complications and demographic data. The authors compared morbidity, including donor-site seroma, total volume of drain discharge, indwelling period of drainage, and length of hospital stay following both MSLD flap and CLD flap breast reconstruction. The demographic data of the 2 groups were not significantly different. Donor-site seroma occurred in 2 MSLD patients (13.3%) and in 6 CLD patients (40.0%). The total volume of the drain discharge and the indwelling period of drainage at donor site were significantly lower in the MSLD group. The length of hospital stay was significantly shorter (by approximately a day and a half) for the MSLD group. The MSLD flap, with its low complication rate and associated minimal functional and aesthetic deficits at the donor site, may be a useful option for small breast reconstruction if earlier discharge from hospital is demanded.
Zhang, Yu; Chen, Yue-Guo; Xia, Ying-Jie; Qi, Hong
2012-09-01
To compare tear cytokines and clinical outcomes between off-flap and on-flap epi-LASIK eyes and explore the possible mechanism for the clinical differences. This double-masked, randomized study enrolled 18 myopic patients who underwent off-flap epi-LASIK with mitomycin C (MMC) in 1 eye and on-flap epi-LASIK with MMC in the contralateral eye. Tears were collected from each eye preoperatively and 2 hours, 1 day, and 5 days postoperatively. Concentrations of multiple tear cytokines were measured by a multiplex immunobead assay. Uncorrected distance visual acuity (UDVA), refraction, haze scores, pain scores, and percentage of corneal epithelial healing were evaluated. Compared with the on-flap group, the off-flap group had outcomes of better UDVA and higher percentages of epithelial healing at 5 days after surgery (P<.001) and lower levels of haze at 1 month after surgery (P=.049). Preoperatively, no significant differences were noted in the release rate of all tear cytokines between groups. At 2 hours postoperatively, the release rate of tear basic fibroblast growth factor (bFGF), platelet-derived growth factor-BB (PDGF-BB), interleukin-8 (IL-8), and tumor necrosis factor alpha (TNF-α) in the off-flap group were significantly lower than those in the on-flap group (P=.011, .017, .048, and .041, respectively). Off-flap epi-LASIK with MMC offers faster corneal epithelial healing and visual recovery, and temporary less haze than on-flap epi-LASIK with MMC. The lower tear levels of bFGF, PDGF-BB, IL-8, and TNF-α in the offflap group 2 hours after surgery may suggest a possible mechanism for the clinical differences. Copyright 2012, SLACK Incorporated.
Reconstruction of Facial Defect Using Deltopectoral Flap.
Aldelaimi, Tahrir N; Khalil, Afrah A
2015-11-01
Reconstruction of the head and neck is a challenge for otolarygology surgeons, maxillofacial surgeons as well as plastic surgeons. Defects caused by the resection and/or trauma should be closed with flaps which match in color, texture and hair bearing characteristics with the face. Deltopectoral flap is a one such flap from chest and neck skin mainly used to cover the facial defects. This study report a patient presenting with tragic Road Traffic Accident (RTA) admitted to maxillofacial surgery department at Ramadi Teaching Hospital, Anbar province, Iraq. An incision, medially based, was done and deltopectoral fascio-cutaneous flap was used for surgical exposure and closure of defects after RTA. There was no major complication. Good aesthetic and functional results were achieved. Deltopectoral flap is an excellent alternative for the reconstruction of head and neck. Harvesting and application of the flap is rapid and safe. Only a single incision is sufficient for dissection and flap elevation.
Innervated boomerang flap for finger pulp reconstruction.
Chen, Shao-Liang; Chiou, Tai-Fung
2007-11-01
The boomerang flap originates from the dorsolateral aspect of the proximal phalanx of an adjacent digit and is supplied by the retrograde blood flow through the vascular arcades between the dorsal and palmar digital arteries. To provide sensation of the boomerang flap for finger pulp reconstruction, the dorsal sensory branch of the proper digital nerve and the superficial sensory branch of the corresponding radial or ulnar nerve are included within the skin flap. After transfer of the flap to the injured site, epineural neurorrhaphies are done between the digital nerves of the pulp and the sensory branches of the flap. We used this sensory flap in five patients, with more than 1 year follow-up, and all patients achieved measurable two-points discrimination. The boomerang flap not only preserves the proper palmar digital artery but also provides an extended and innervated skin paddle. It seems to be an alternative choice for one-stage reconstruction of major pulp defect.
Refining the intrinsic chimera flap: a review.
Agarwal, Jayant P; Agarwal, Shailesh; Adler, Neta; Gottlieb, Lawrence J
2009-10-01
Reconstruction of complex tissue deficiencies in which each missing component is in a different spatial relationship to each other can be particularly challenging, especially in patients with limited recipient vessels. The chimera flap design is uniquely suited to reconstruct these deformities. Chimera flaps have been previously defined in many ways with 2 main categories: prefabricated or intrinsic. Herein we attempt to clarify the definition of a true intrinsic chimeric flap and provide examples of how these constructs provide a method for reconstruction of complex defects. The versatility of the intrinsic chimera flap and its procurement from 7 different vascular systems is described. A clarification of the definition of a true intrinsic chimera flap is described. In addition, construction of flaps from the lateral femoral circumflex, deep circumflex iliac, inferior gluteal, peroneal, subscapular, thoracodorsal, and radial arterial systems is described to showcase the versatility of these chimera flaps. A true intrinsic chimera flap must consist of more than a single tissue type. Each of the tissue components receives its blood flow from separate vascular branches or perforators that are connected to a single vascular source. These vascular branches must be of appropriate length to allow for insetting with 3-dimensional spatial freedom. There are a multitude of sites from which true intrinsic chimera flaps may be harvested.
To flap or not to flap: a discussion between a fish and a jellyfish
NASA Astrophysics Data System (ADS)
Martin, Nathan; Roh, Chris; Idrees, Suhail; Gharib, Morteza
2016-11-01
Fish and jellyfish are known to swim by flapping and by periodically contracting respectively, but which is the more effective propulsion mechanism? In an attempt to answer this question, an experimental comparison is made between simplified versions of these motions to determine which generates the greatest thrust for the least power. The flapping motion is approximated by pitching plates while periodic contractions are approximated by clapping plates. A machine is constructed to operate in either a flapping or a clapping mode between Reynolds numbers 1,880 and 11,260 based on the average plate tip velocity and span. The effect of the total sweep angle, total sweep time, plate flexibility, and duty cycle are investigated. The average thrust generated and power required per cycle are compared between the two modes when their total sweep angle and total sweep time are identical. In general, operating in the clapping mode required significantly more power to generate a similar thrust compared to the flapping mode. However, modifying the duty cycle for clapping caused the effectiveness to approach that of flapping with an unmodified duty cycle. These results suggest that flapping is the more effective propulsion mechanism within the range of Reynolds numbers tested. This work was supported by the Charyk Bio-inspired Laboratory at the California Institute of Technology, the National Science Foundation Graduate Research Fellowship under Grant No. DGE-1144469, and the Summer Undergraduate Research Fellowships program.
Aeroacoustic Measurements of a Wing-Flap Configuration
NASA Technical Reports Server (NTRS)
Meadows, Kristine R.; Brooks, Thomas F.; Humphreys, William M.; Hunter, William H.; Gerhold, Carl H.
1997-01-01
Aeroacoustic measurements are being conducted to investigate the mechanisms of sound generation in high-lift wing configurations, and initial results are presented. The model is approximately 6 percent of a full scale configuration, and consists of a main element NACA 63(sub 2) - 215 wing section and a 30 percent chord half-span flap. Flow speeds up to Mach 0.17 are tested at Reynolds number up to approximately 1.7 million. Results are presented for a main element at a 16 degree angle of attack, and flap deflection angles of 29 and 39 degrees. The measurement systems developed for this test include two directional arrays used to localize and characterize the noise sources, and an array of unsteady surface pressure transducers used to characterize wave number spectra and correlate with acoustic measurements. Sound source localization maps show that locally dominant noise sources exist on the flap-side edge. The spectral distribution of the noise sources along the flap-side edge shows a decrease in frequency of the locally dominant noise source with increasing distance downstream of the flap leading edge. Spectra are presented which show general spectral characteristics of Strouhal dependent flow-surface interaction noise. However, the appearance of multiple broadband tonal features at high frequency indicates the presence of aeroacoustic phenomenon following different scaling characteristics. The scaling of the high frequency aeroacoustic phenomenon is found to be different for the two flap deflection angles tested. Unsteady surface pressure measurements in the vicinity of the flap edge show high coherence levels between adjacent sensors on the flap-side edge and on the flap edge upper surface in a region which corresponds closely to where the flap-side edge vortex begins to spill over to the flap upper surface. The frequency ranges where these high levels of coherence occur on the flap surface are consistent with the frequency ranges in which dominant features
Yang, Heping; Zhang, Hongwu; Chen, Haidi; Yang, Shuxiong; Wang, Jun; Hu, Dawang
2016-04-01
To compare the effectiveness of complex defects repair between using chimeric anterolateral thigh flap and series-wound flaps after resection of oral and maxillofacial cancer. After resection of oral and maxillofacial cancer, defect was repaired with chimeric anterolateral thigh flap in 39 patients between January 2011 and July 2014 (chimeric anterolateral thigh flap group); and defect was repaired with series-wound flaps in 35 patients between January 2009 and December 2010 (series-wound flaps group). There was no significant difference in gender, age, duration of disease, tumor type, tumor staging, defect location, and defect area between 2 groups (P > 0.05). The operation time, flap harvesting and microvascular anastomosis time, stomach tube extraction time, and oral feeding time were recorded and compared between 2 groups, and postoperative complications were observed; the effectiveness was evaluated according to clinical efficacy evaluation table of bone and soft tissue defects reconstruction surgery in oral and maxillofacial region. Vascular crisis occurred in 2 cases of chimeric anterolateral thigh flap group, and 4 cases of series-wound flaps group. Partial necrosis appeared at distal end of a series-wound flaps, and oral fistula and infection developed in 3 series-wound flaps. The other flaps and the grafted skin at donor site survived; wounds at recipient site healed by first intention. The operation time, stomach tube extraction time, and oral feeding time of chimeric anterolateral thigh flap group were significantly shorter than those of series-wound flaps group (P < 0.05), while the flap harvesting and microvascular anastomosis time was significantly longer than that of series-wound flaps group (P < 0.05). The patients were followed up 1-5 years (mean, 2.5 years). At 3 months after operation, the appearance, patients' satisfaction, working conditions, oral closure function, chew, language performance, and swallowing scores of the chimeric anterolateral
Wu, Liza C; Iteld, Lawrence; Song, David H
2008-06-01
Autologous breast reconstruction with the transverse rectus abdominis musculocutaneous (TRAM) flap is traditionally based on either the superior epigastric vessels (pedicled) or the deep inferior system (free). In the overweight and obese population, both techniques have been shown to have increased complications of the reconstructed breast. Another alternative is supercharging the flap by anastamosing the deep inferior epigastric vessels to either the internal mammary or thoracodorsal systems. We present a single surgeon's experience with unilateral TRAM reconstructions supercharged to either the thoracodorsal vessels, the internal mammary system, or in one case, perforator vessels in overweight and obese patients. Nineteen consecutive overweight or obese patients underwent delayed or immediate, unilateral autologous breast reconstruction with supercharged TRAM flaps between November 2000 and November 2004. The patients ranged in age from 28 to 66 years (average 49) and had an average body mass index (BMI) of 29.5 (24.9-38.3). Twelve patients had a BMI between 25 and 29.9 kg/m2; 7 patients had BMI > or =30 kg/m2. Left-sided reconstructions were 13; right-sided reconstructions were 6. Supercharging was performed by anastamosing the deep inferior epigastric artery and vein to the thoracodorsal vessels, internal mammary vessels, or perforator vessels. Follow-up ranged from 6 to 54 months. There was a qualitative increase in blood flow measured by audible Doppler signals in all patients after the arterial and venous anastamoses. There were no cases of partial or complete flap loss. One patient had a hematoma and subsequently developed minor fat necrosis. One patient had an infection of the reconstructed breast. There were no donor site complications. Supercharging the TRAM flap by means of microvascular augmentation of the deep inferior epigastric vessels provides a safe and effective breast reconstruction in the overweight and obese population with no additional
The First Dorsal Metatarsal Artery Perforator Propeller Flap.
Hallock, Geoffrey G
2016-06-01
Distal foot and toe defects requiring a vascularized flap for coverage have very limited options, oftentimes justifying even a free flap. Perforator flaps in general and propeller flaps in particular have opened up an entirely new subset of local tissue transfer alternatives that can potentially avoid the difficulties that accompany microvascular tissue transfers. The first dorsal metatarsal artery (FDMA) perforator propeller flap represents another variation of this theme. A standard FDMA flap from the dorsum of the foot was raised in reversed fashion based on the distal communicating branch or "perforator" from the plantar foot circulation in 2 patients with great toe defects. All distal skin tissue between this perforator and the defect was kept with the FDMA flap as an attached minor blade, to thereby create an FDMA propeller flap. Salvage of the great toe in both patients was achieved. The benefit of the minor blade of the propeller was to fill a portion of the donor site defect of the traditional FDMA major blade, to permit tension-free donor site closure of the dorsal foot without sequela. The distal-based FDMA flap can be useful as a local flap for coverage of distal foot and toe wounds, but direct donor site closure can be problematic as mirrored by its relative the dorsalis pedis flap. The FDMA perforator propeller flap variation can achieve the same reconstructive goals while simultaneously transferring vascularized tissue into the dorsal foot donor site to thereby minimize the tension if direct closure is possible or minimize the need for a skin graft in this notoriously difficult region.
Kocman, A Emre; Kose, Aydan A; Karabagli, Yakup; Baycu, Cengiz; Cetin, Cengiz
2008-01-01
Composite flaps including soft tissues with bone or cartilage are widely used in reconstruction of three-dimensional defects, but have some disadvantages. Flap prefabrication with alloplastic implants is an alternative procedure. Axial pattern vascularised high density porous polyethylene (HDPP) implants are capable of sustaining skin grafts. The purpose of this study was to examine the vascularisation pattern of the skin island in a composite flap prefabrication model prepared with vascularised HDPP implants. Forty male Wistar rats divided into four groups were used. A 9.5 x 6 x 2 mm HDPP block was centered on the dissected saphenous pedicle and anchored under the abdominal skin in the experimental group I (n=10). In experimental group II (n=10) saphenous artery and vein were put between the skin and the implant. Thus, the structures were laid as skin, HDPP block, pedicle in experimental group I and skin, pedicle, HDPP block in experimental group II. HDPP block-implanted and pedicle-implanted only groups served as control groups I and II, respectively. Eight weeks after prefabrication, skin islands 1.5 x 5 cm in size incorporated with implants were elevated based on saphenous vessels in the experimental groups and skin islands only based on the pedicle in control group II. Skin islands of the same dimensions were raised as grafts in control group I. Nylon sheets were put under the flaps and grafts to prevent vascularisation from the recipient bed. Flap viability was assessed by measuring the surface area on the 7th day. Total necrosis developed in composite grafts of control group I. Flap survival was higher in experimental group II and control group II (45% and 46.8%) than in group I (29.28%). Histologic studies demonstrated fibrovascular ingrowth into the HDPP implants, except in control group I, with significant inflammatory response and necrosis. Vascularisation of skin and implants from the pedicle was seen also microangiographically. In conclusion, a
Retention of a reconstructed nipple using a C-V flap with different layer thicknesses in the C-flap.
Sowa, Yoshihiro; Itsukage, Sizu; Sakaguchi, Kouichi; Taguchi, Tetsuya; Numajiri, Toshiaki
2018-04-01
The C-V flap for nipple reconstruction is now one of standard surgical techniques. But decreased projection is still a problem. In recent years, it has been suggested that projection can be more easily maintained when raising of the C-flap is performed with a split thickness dermis. In this study, we examined whether decrease of projection can be prevented by raising of a C-flap with a split dermis rather than with full dermis. A total of 49 consecutive patients who underwent reconstruction of a nipple using the C-V flap technique were enrolled. The patients included 22 who underwent surgery using a C-flap with a full thickness dermis (Group F), and 27 who underwent surgery with raising of a flap with a split thickness dermis (Group S). The size of the reconstructed nipple was measured at 2 weeks, 6 months and 1 year postoperatively for comparison between Groups F and S. Partial necrosis of the C-flap end occurred in 4 subjects in only Group S. The decrease in projection after 1 year postoperatively in Group S was significantly lower than that in Group F. In contrast, the teat base size in Group F tended to be greater than that in Group S, suggesting a tendency for an expanded base using a flap with a full dermis. Our results indicated that it is recommended to use a C-flap with a split dermis for cases with high projection of the nipple on the contralateral side.
Parasacral Perforator Flaps for Reconstruction of Sacral Pressure Sores.
Lin, Chin-Ta; Chen, Shih-Yi; Chen, Shyi-Gen; Tzeng, Yuan-Sheng; Chang, Shun-Cheng
2015-07-01
Despite advances in reconstruction techniques, pressure sores continue to present a challenge to the plastic surgeon. The parasacral perforator flap is a reliable flap that preserves the entire contralateral side as a future donor site. On the ipsilateral side, the gluteal muscle itself is preserved and all flaps based on the inferior gluteal artery are still possible. We present our experience of using parasacral perforator flaps in reconstructing sacral defects. Between August 2004 and January 2013, 19 patients with sacral defects were included in this study. All the patients had undergone surgical reconstruction of sacral defects with a parasacral perforator flap. The patients' sex, age, cause of sacral defect, flap size, flap type, numbers of perforators used, rotation angle, postoperative complications, and hospital stay were recorded. There were 19 parasacral perforator flaps in this series. All flaps survived uneventfully except for 1 parasacral perforator flap, which failed because of methicillin-resistant Staphylococcus aureus infection. The overall flap survival rate was 95% (18/19). The mean follow-up period was 17.3 months (range, 2-24 months). The average length of hospital stay was 20.7 days (range, 9-48 days). No flap surgery-related mortality was found. Also, there was no recurrence of sacral pressure sores or infected pilonidal cysts during the follow-up period. Perforator-based flaps have become popular in modern reconstructive surgery because of low donor-site morbidity and good preservation of muscle. Parasacral perforator flaps are durable and reliable in reconstructing sacral defects. We recommend the parasacral perforator flap as a good choice for reconstructing sacral defects.
NASA Technical Reports Server (NTRS)
Wentz, W. H., Jr.; Fiscko, K. A.
1978-01-01
Surface pressure distributions were measured for the 13% thick GA(W)-2 airfoil section fitted with 20% aileron, 25% slotted flap and 30% Fowler flap. All tests were conducted at a Reynolds number of 2.2 x 10 to the 6th power and a Mach number of 0.13. Pressure distribution and force and moment coefficient measurements are compared with theoretical results for a number of cases. Agreement between theory and experiment is generally good for low angles of attack and small flap deflections. For high angles and large flap deflections where regions of separation are present, the theory is inadequate. Theoretical drag predictions are poor for all flap-extended cases.
The possibility for use of venous flaps in plastic surgery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baytinger, V. F., E-mail: baitinger@mail.tomsknet.ru; Kurochkina, O. S., E-mail: kurochkinaos@yandex.ru; Selianinov, K. V.
2015-11-17
The use of venous flaps is controversial. The mechanism of perfusion of venous flaps is still not fully understood. The research was conducted on 56 white rats. In our experimental work we studied two different models of venous flaps: pedicled venous flap (PVF) and pedicled arterialized venous flap (PAVF). Our results showed that postoperative congestion was present in all flaps. However 66.7% of all pedicled venous flaps and 100% of all pedicled arterialized venous flaps eventually survived. Histological examination revealed that postoperatively the blood flow in the skin of the pedicled arterialized venous flap became «re-reversed» again; there were nomore » differences between mechanism of survival of venous flaps and other flaps. On the 7-14th day in the skin of all flaps were processes of neoangiogenesis and proliferation. Hence the best scenario for the clinical use of venous flaps unfolds when both revascularization and skin coverage are required.« less
Translational damping on high-frequency flapping wings
NASA Astrophysics Data System (ADS)
Parks, Perry A.
Flapping fliers such as insects and birds depend on passive translational and rotational damping to terminate quick maneuvers and to provide a source of partial stability in an otherwise unstable dynamic system. Additionally, passive translational and rotational damping reduce the amount of active kinematic changes that must be made to terminate maneuvers and maintain stability. The study of flapping-induced damping phenomena also improves the understanding of micro air vehicle (MAV) dynamics needed for the synthesis of effective flight control strategies. Aerodynamic processes which create passive translational and rotational damping as a direct result of symmetric flapping with no active changes in wing kinematics have been previously studied and were termed flapping counter-force (FCF) and flapping counter-torque (FCT), respectively. In this first study of FCF measurement in air, FCF generation is measured using a pendulum system designed to isolate and measure the relationship of translational flapping-induced damping with wingbeat frequency for a 2.86 gram mechanical flapper equipped with real cicada wings. Analysis reveals that FCF generation and wingbeat frequency are directly proportional, as expected from previous work. The quasi-steady FCF model using Blade-Element-Theory is used as an estimate for translational flapping-induced damping. In most cases, the model proves to be accurate in predicting the relationship between flapping-induced damping and wingbeat frequency. "Forward-backward" motion proves to have the strongest flapping-induced damping while "up-down" motion has the weakest.
Microsurgical free flaps: Controversies in maxillofacial reconstruction
George, Rinku K.; Krishnamurthy, Arvind
2013-01-01
Reconstructive microsurgery for oral and maxillofacial (OMF) defects is considered as a niche specialty and is performed regularly only in a handful of centers. Till recently the pectoralis major myocutaneous flap (PMMC) was considered to be the benchmark for OMF reconstruction. This philosophy is changing fast with rapid advancement in reconstructive microsurgery. Due to improvement in instrumentation and the development of finer techniques of flap harvesting we can positively state that microsurgery has come of age. Better techniques, microscopes and micro instruments enable us to do things previously unimaginable. Supramicrosurgery and ultrathin flaps are a testimony to this. Years of innovation in reconstructive microsurgery have given us a reasonably good number of very excellent flaps. Tremendous work has been put into producing some exceptionally brilliant research articles, sometimes contradicting each other. This has led to the need for clarity in some areas in this field. This article will review some controversies in reconstructive microsurgery and analyze some of the most common microvascular free flaps (MFF) used in OMF reconstruction. It aims to buttress the fact that three flaps-the radial forearm free flap (RFFF), anterolateral thigh flap (ALT) and fibula are the ones most expedient in the surgeon's arsenal, since they can cater to almost all sizeable defects we come across after ablative surgery in the OMF region. They can thus aptly be titled as the workhorses of OMF reconstruction with regard to free flaps. PMID:23662264
The gust-mitigating potential of flapping wings.
Fisher, Alex; Ravi, Sridhar; Watkins, Simon; Watmuff, Jon; Wang, Chun; Liu, Hao; Petersen, Phred
2016-08-02
Nature's flapping-wing flyers are adept at negotiating highly turbulent flows across a wide range of scales. This is in part due to their ability to quickly detect and counterract disturbances to their flight path, but may also be assisted by an inherent aerodynamic property of flapping wings. In this study, we subject a mechanical flapping wing to replicated atmospheric turbulence across a range of flapping frequencies and turbulence intensities. By means of flow visualization and surface pressure measurements, we determine the salient effects of large-scale freestream turbulence on the flow field, and on the phase-average and fluctuating components of pressure and lift. It is shown that at lower flapping frequencies, turbulence dominates the instantaneous flow field, and the random fluctuating component of lift contributes significantly to the total lift. At higher flapping frequencies, kinematic forcing begins to dominate and the flow field becomes more consistent from cycle to cycle. Turbulence still modulates the flapping-induced flow field, as evidenced in particular by a variation in the timing and extent of leading edge vortex formation during the early downstroke. The random fluctuating component of lift contributes less to the total lift at these frequencies, providing evidence that flapping wings do indeed provide some inherent gust mitigation.
Pressure Distribution Over Airfoils with Fowler Flaps
NASA Technical Reports Server (NTRS)
Wenzinger, Carl J; Anderson, Walter B
1938-01-01
Report presents the results of tests made of a Clark y airfoil with a Clark y Fowler flap and of an NACA 23012 airfoil with NACA Fowler flaps. Some of the tests were made in the 7 by 10-foot wind tunnel and others in the 5-foot vertical wind tunnel. The pressures were measured on the upper and lower surfaces at one chord section both on the main airfoils and on the flaps for several angles of attack with the flaps located at the maximum-lift settings. A test installation was used in which the model was mounted in the wind tunnel between large end planes so that two-dimensional flow was approximated. The data are given in the form of pressure-distribution diagrams and as plots of calculated coefficients for the airfoil-and-flap combinations and for the flaps alone.
Mani, Marc
2016-01-01
Background Recent anatomic studies suggest the superficial musculoaponeurotic system (SMAS) layer attenuates in the midface. This led the author to switch from a bilamellar high SMAS dissection to a “total composite flap” technique, preserving skin and SMAS/platysma as one layer in a critical “deep-plane transition zone” (DTZ) lateral to the zygomaticus major muscle. This allows traction on the SMAS to translate to the malar fat pad via a “cantilever bridge” effect, which is lost when skin is undermined in the DTZ. Objectives This paper attempts to answer the question of whether the composite flap or bilamellar technique better lifts the midface, comparing groups where the DTZ was undermined: (1) only at a sub-SMAS level; or (2) at both subcutaneous and sub-SMAS levels. Methods Thirty-five patients underwent bilamellar facelifts with skin and SMAS separated in the DTZ. Midfacial elevation was measured using size-matched preoperative and 18-month (average) postoperative photographs for the 70 hemi-midfaces. The same analysis was done for 35 patients undergoing total composite flap facelift, maintaining skin and SMAS as one layer in the DTZ. The two groups were compared. Results In the bilamellar group, the mean percentage of midfacial elevation at 18 months postoperative was 5.5% (range, 0.0%-17.8%). In the composite flap group, the percentage was 11.7% (range, 0.1%-32.3%). The difference was statistically significant. Conclusions Maintaining skin-SMAS attachments in the DTZ improves midface elevation during SMAS facelifting, exploiting a “cantilever bridge” effect of the skin transferring traction on the SMAS to the malar fat pad. Level of Evidence: 4 Therapeutic PMID:26931306
Ma, Xianjie; Li, Yang; Li, Weiyang; Liu, Chaohua; Peng, Pai; Song, Baoqiang; Xia, Wensen; Yi, Chenggang; Lu, Kaihua; Su, Yingjun
2017-09-01
The scars of face and scalp caused by burning often show as 1 large facial-scalp scar. The deltopectoral flap was recognized as one of the first choices for the facial scar reconstruction. However, this flap cannot cross the level of zygomatic arch traditionally when it was transferred with pedicle. When the flap reconstructed the facial-scalp scars with expanded random scalp flap, another flap was often needed to reconstruct the remaining temple and forehead scars. The authors reviewed 24 patients of large facial-scalp scars reconstructed by expanded pedicled deltopectoral flap and scalp flap with several technique improvements. The seaming scar between the deltopectoral flap and scalp flap in the temple region formed the new hairline. The technique improvements included ligation of the perforating branches of the transverse cervical artery and thoracoacromial artery when dissecting the pocket, the partial bolster compressive dressing to the distal part of the flap and dividing the pedicle partly as a delaying procedure before dividing the pedicle completely. Good skin compliance, normal contours, and emotional expression were noted. There were complications including expander exposure in 3 patients, stretch marks in 5 patients, flap tip necrosis in 2 patients, and mild postoperative hypertrophic scars in 3 patients. In conclusion, the expanded pedicled deltopectoral flap can enlarge the reconstructive territory in face successfully with the technique improvements. The combination of the expanded pedicled deltopectoral flap and scalp flap is a reliable and excellent reconstructive option for large postburn facial-scalp scars.
Vortex leading edge flap assembly for supersonic airplanes
NASA Technical Reports Server (NTRS)
Rudolph, Peter K. C. (Inventor)
1997-01-01
A leading edge flap (16) for supersonic transport airplanes is disclosed. In its stowed position, the leading edge flap forms the lower surface of the wing leading edge up to the horizontal center of the leading edge radius. For low speed operation, the vortex leading edge flap moves forward and rotates down. The upward curve of the flap leading edge triggers flow separation on the flap and rotational flow on the upper surface of the flap (vortex). The rounded shape of the upper fixed leading edge provides the conditions for a controlled reattachment of the flow on the upper wing surface and therefore a stable vortex. The vortex generates lift and a nose-up pitching moment. This improves maximum lift at low speed, reduces attitude for a given lift coefficient and improves lift to drag ratio. The mechanism (27) to move the vortex flap consists of two spanwise supports (24) with two diverging straight tracks (64 and 68) each and a screw drive mechanism (62) in the center of the flap panel (29). The flap motion is essentially normal to the airloads and therefore requires only low actuation forces.
Misani, M; Zirak, C; Hau, Lê Thua Trung; De Mey, A; Boeckx, W
2013-08-01
The use of microsurgery in the management of burn sequelae is not a new idea. According to the properties of various types of free flaps different goals can be achieved or various additional procedures have to be combined. We report the comparison of two different free flaps on a single patient for reconstruction of both upper extremities for burn sequelae. A 1-year-old child sustained severe burns on both hands, arms and thorax and was initially only treated conservatively. This resulted in severe contractures. At the age of 4-years a free gracilis flap was selected for reconstruction of his left hand and a free anterolateral thigh flap for the right hand. We noticed a better functional and esthetic result for the gracilis flap associated with a shorter operative time and a minor donor site morbidity. The intraoperative technique and time, postoperative complications, functional and esthetic results and donor site morbidities were studied in the two types of flaps chosen. A review of literature was also performed. Our experience reported a better success of the gracilis muscle flap covered with a split skin graft compared to the anterolateral thigh flap in the reconstruction of hand function after severe burn sequelae. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.
Kazzazi, Fawz; Ching, Rosanna C; Malata, Charles M
2018-01-01
Introduction: Thin women have fewer autologous tissue breast reconstructive options than their higher body mass index counterparts-due to a lack of adequate donor sites. They are therefore usually offered expander/implant techniques. The total autologous latissimus dorsi flap is generally used in "well-padded" individuals, as they have enough fat on their back on which a completely autologous reconstruction could be based. When implant-based reconstruction is contraindicated (for instance due to planned adjuvant radiotherapy) or unacceptable to the patient, the total autologous latissimus dorsi flap can provide adequate tissue volume by utilizing the additional back fat deposits even in the thin, small-breasted patient. This option is often overlooked by many surgeons. Our case series assesses indications and patient and surgeon satisfaction with the cosmetic outcome of this technique. Methods: The oncological and clinical details of 6 patients with breast cancer who underwent total autologous latissimus dorsi myocutaneous flap immediate breast reconstruction by a single surgeon over an 8-year period were reviewed. An objective assessment of satisfaction with the cosmetic result was made by whether any additional surgical interventions (ipsilateral fat grafting/implant augmentation or contralateral liposuction/ reduction) were needed or not. A subjective assessment of breast symmetry by the surgeon using photographic records was also undertaken. The aesthetic outcomes were also objectively quantified using the BCCT.core software, initially developed for assessing the results of breast conservation surgery. Results: All 6 patients had small breasts and a low or normal body mass index. The mastectomies were performed for invasive carcinoma (n = 3) and extensive high-grade ductal carcinoma in situ (n = 3). Four had axillary surgery (2 sentinel lymph node biopsies and 2 axillary clearances), and 3 received adjuvant radiotherapy. All were happy with their reconstructive
Kazzazi, Fawz; Ching, Rosanna C.; Malata, Charles M.
2018-01-01
Introduction: Thin women have fewer autologous tissue breast reconstructive options than their higher body mass index counterparts—due to a lack of adequate donor sites. They are therefore usually offered expander/implant techniques. The total autologous latissimus dorsi flap is generally used in “well-padded” individuals, as they have enough fat on their back on which a completely autologous reconstruction could be based. When implant-based reconstruction is contraindicated (for instance due to planned adjuvant radiotherapy) or unacceptable to the patient, the total autologous latissimus dorsi flap can provide adequate tissue volume by utilizing the additional back fat deposits even in the thin, small-breasted patient. This option is often overlooked by many surgeons. Our case series assesses indications and patient and surgeon satisfaction with the cosmetic outcome of this technique. Methods: The oncological and clinical details of 6 patients with breast cancer who underwent total autologous latissimus dorsi myocutaneous flap immediate breast reconstruction by a single surgeon over an 8-year period were reviewed. An objective assessment of satisfaction with the cosmetic result was made by whether any additional surgical interventions (ipsilateral fat grafting/implant augmentation or contralateral liposuction/ reduction) were needed or not. A subjective assessment of breast symmetry by the surgeon using photographic records was also undertaken. The aesthetic outcomes were also objectively quantified using the BCCT.core software, initially developed for assessing the results of breast conservation surgery. Results: All 6 patients had small breasts and a low or normal body mass index. The mastectomies were performed for invasive carcinoma (n = 3) and extensive high-grade ductal carcinoma in situ (n = 3). Four had axillary surgery (2 sentinel lymph node biopsies and 2 axillary clearances), and 3 received adjuvant radiotherapy. All were happy with their
Efficient flapping flight of pterosaurs
NASA Astrophysics Data System (ADS)
Strang, Karl Axel
In the late eighteenth century, humans discovered the first pterosaur fossil remains and have been fascinated by their existence ever since. Pterosaurs exploited their membrane wings in a sophisticated manner for flight control and propulsion, and were likely the most efficient and effective flyers ever to inhabit our planet. The flapping gait is a complex combination of motions that sustains and propels an animal in the air. Because pterosaurs were so large with wingspans up to eleven meters, if they could have sustained flapping flight, they would have had to achieve high propulsive efficiencies. Identifying the wing motions that contribute the most to propulsive efficiency is key to understanding pterosaur flight, and therefore to shedding light on flapping flight in general and the design of efficient ornithopters. This study is based on published results for a very well-preserved specimen of Coloborhynchus robustus, for which the joints are well-known and thoroughly described in the literature. Simplifying assumptions are made to estimate the characteristics that can not be inferred directly from the fossil remains. For a given animal, maximizing efficiency is equivalent to minimizing power at a given thrust and speed. We therefore aim at finding the flapping gait, that is the joint motions, that minimize the required flapping power. The power is computed from the aerodynamic forces created during a given wing motion. We develop an unsteady three-dimensional code based on the vortex-lattice method, which correlates well with published results for unsteady motions of rectangular wings. In the aerodynamic model, the rigid pterosaur wing is defined by the position of the bones. In the aeroelastic model, we add the flexibility of the bones and of the wing membrane. The nonlinear structural behavior of the membrane is reduced to a linear modal decomposition, assuming small deflections about the reference wing geometry. The reference wing geometry is computed for
Grant, Michael D
2015-02-01
One of the most challenging procedures in breast surgery is the skin-sparing mastectomy (SSM). Various techniques and incisions have evolved that characterize this procedure; however, what is common in all of them is the smaller the incision, the more difficult it is to develop the skin flaps. A procedure was developed that incorporates the use of liposuction cannulas (without suction) to create the skin flaps. The technique and results are described in this manuscript. From October of 2012 to April 2014, 289 mastectomies (171 patients) were performed using the CAFE procedure on women of all shapes and sizes. Postoperatively, no problems were experienced with flap viability using this technique. The main difference in side effects between the CAFE technique and other standard techniques for developing flaps in SSMs was more bruising than normal, but this resolved rapidly. The results for use of this technique were consistently impressive. The learning curve for this procedure is very short, especially for those who perform SSMs using sharp technique (scissors). Residents and fellows became proficient with the CAFE technique in a relatively short amount of time. Plastic surgeons were pleased with the cosmetic outcomes of their reconstructions that follow this type of mastectomy. Patients were extremely satisfied with their reconstructions as well. Incorporating the use of liposuction cannulas (without suction) makes the creation of flaps for SSM a relatively simple and rapid method. It is especially useful to assist in developing skin flaps with even the smallest of skin incisions.
The role of postoperative hematoma on free flap compromise.
Ahmad, Faisal I; Gerecci, Deniz; Gonzalez, Javier D; Peck, Jessica J; Wax, Mark K
2015-08-01
Hematomas may develop in the postoperative setting after free tissue transfer. When hematomas occur, they can exert pressure on surrounding tissues. Their effect on the vascular pedicle of a free flap is unknown. We describe our incidence of hematoma in free flaps and outcomes when the flap is compromised. Retrospective chart review of 1,883 free flaps performed between July 1998 and June 2014 at a tertiary referral center. Patients with free flap compromise due to hematoma were identified. Etiology, demographic data, and outcomes were evaluated. Eighty-eight (4.7%) patients developed hematomas. Twenty (22.7%) of those had flap compromise. Twelve compromises (60%) showed evidence of pedicle thrombosis. The salvage rate was 75% versus 54% in 79 flaps with compromise from other causes (P = .12). Mean time to detection of the hematoma was 35.3 hours in salvaged flaps compared to 91.6 hours in unsalvageable flaps (P = .057). Time to operating room (OR) from detection was 2.8 hours in salvageable flaps compared to 12.4 hours in nonsalvageable flaps (P = .053). The salvage rate for flaps that returned to the OR in <5 hours was 93.3% compared to 20% (P = .0049) for those that did not. Vascular thrombosis reduced salvage rate to 58.3% from 100% (P = .002) when there was no thrombosis. In our series hematomas developed rarely. When they did, 23% went on to develop flap compromise. Prompt recognition and re-exploration allowed for a high salvage rate. Vessel thrombosis predicted inability to salvage the flap. 4 © 2015 The American Laryngological, Rhinological and Otological Society, Inc.
Mandibular reconstruction in irradiated patients utilizing myosseous-cutaneous flaps
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pearlman, N.W.; Albin, R.E.; O'Donnell, R.S.
1983-10-01
Myosseous-cutaneous flaps were used for mandibular reconstruction in 16 irradiated patients. Three of six sternomastoid-clavicle flaps failed (all in conjunction with a neck dissection), as did one of 10 pectoralis major-anterior-fifth rib flaps. One trapezius-scapular flap was used and it succeeded. We found the blood supply of the sternomastoid-clavicle flap too tenuous for use in conjunction with a neck dissection. The trapezius-scapular flap had too short an arc of rotation to be used for defects other than those in the horizontal ramus. In addition, this flap required a change of position and created an undesirable functional deformity. The pectoralis major-fifthmore » rib flap, in contrast, could be used for a variety of defects, in conjunction with a neck dissection, and did not require a change of position during operation. We found it to be the most versatile and dependable of the flaps employed in this series.« less
50 CFR Figure 16 to Part 223 - Escape Opening and Flap Dimensions for the Double Cover Flap TED
Code of Federal Regulations, 2014 CFR
2014-10-01
... 50 Wildlife and Fisheries 10 2014-10-01 2014-10-01 false Escape Opening and Flap Dimensions for the Double Cover Flap TED 16 Figure 16 to Part 223 Wildlife and Fisheries NATIONAL MARINE FISHERIES... MARINE AND ANADROMOUS SPECIES Pt. 223, Fig. 16 Figure 16 to Part 223—Escape Opening and Flap Dimensions...
50 CFR Figure 16 to Part 223 - Escape Opening and Flap Dimensions for the Double Cover Flap TED
Code of Federal Regulations, 2013 CFR
2013-10-01
... 50 Wildlife and Fisheries 10 2013-10-01 2013-10-01 false Escape Opening and Flap Dimensions for the Double Cover Flap TED 16 Figure 16 to Part 223 Wildlife and Fisheries NATIONAL MARINE FISHERIES... MARINE AND ANADROMOUS SPECIES Pt. 223, Fig. 16 Figure 16 to Part 223—Escape Opening and Flap Dimensions...
Tsutakawa, Susan E.; Thompson, Mark J.; Arvai, Andrew S.; ...
2017-06-27
DNA replication and repair enzyme Flap Endonuclease 1 (FEN1) is vital for genome integrity, and FEN1 mutations arise in multiple cancers. FEN1 precisely cleaves single-stranded (ss) 5'-flaps one nucleotide into duplex (ds) DNA. Yet, how FEN1 selects for but does not incise the ss 5'-flap was enigmatic. Here we combine crystallographic, biochemical and genetic analyses to show that two dsDNA binding sites set the 5'polarity and to reveal unexpected control of the DNA phosphodiester backbone by electrostatic interactions. Via phosphate steering', basic residues energetically steer an inverted ss 5'-flap through a gateway over FEN1's active site and shift dsDNA formore » catalysis. Mutations of these residues cause an 18,000-fold reduction in catalytic rate in vitro and large-scale trinucleotide (GAA) n repeat expansions in vivo, implying failed phosphate-steering promotes an unanticipated lagging-strand template-switch mechanism during replication. Thus, phosphate steering is an unappreciated FEN1 function that enforces 5'-flap specificity and catalysis, preventing genomic instability.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsutakawa, Susan E.; Thompson, Mark J.; Arvai, Andrew S.
DNA replication and repair enzyme Flap Endonuclease 1 (FEN1) is vital for genome integrity, and FEN1 mutations arise in multiple cancers. FEN1 precisely cleaves single-stranded (ss) 5'-flaps one nucleotide into duplex (ds) DNA. Yet, how FEN1 selects for but does not incise the ss 5'-flap was enigmatic. Here we combine crystallographic, biochemical and genetic analyses to show that two dsDNA binding sites set the 5'polarity and to reveal unexpected control of the DNA phosphodiester backbone by electrostatic interactions. Via phosphate steering', basic residues energetically steer an inverted ss 5'-flap through a gateway over FEN1's active site and shift dsDNA formore » catalysis. Mutations of these residues cause an 18,000-fold reduction in catalytic rate in vitro and large-scale trinucleotide (GAA) n repeat expansions in vivo, implying failed phosphate-steering promotes an unanticipated lagging-strand template-switch mechanism during replication. Thus, phosphate steering is an unappreciated FEN1 function that enforces 5'-flap specificity and catalysis, preventing genomic instability.« less
Pre-expanded Intercostal Perforator Super-Thin Skin Flap.
Liao, Yunjun; Luo, Yong; Lu, Feng; Hyakusoku, Hiko; Gao, Jianhua; Jiang, Ping
2017-01-01
This article introduces pre-expanded super-thin intercostal perforator flaps, particularly the flap that has a perforator from the first to second intercostal spaces. The key techniques, advantages and disadvantages, and complications and management of this flap are described. At present, the thinnest possible flap is achieved by thinning the pre-expanded flap that has a perforator from the first to second intercostal spaces. It is used to reconstruct large defects on the face and neck, thus restoring function and cosmetic appearance. Copyright © 2016 Elsevier Inc. All rights reserved.
14 CFR 25.1511 - Flap extended speed.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Flap extended speed. 25.1511 Section 25.1511 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT... Limitations § 25.1511 Flap extended speed. The established flap extended speed V FE must be established so...
14 CFR 25.1511 - Flap extended speed.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Flap extended speed. 25.1511 Section 25.1511 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT... Limitations § 25.1511 Flap extended speed. The established flap extended speed V FE must be established so...
14 CFR 25.1511 - Flap extended speed.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Flap extended speed. 25.1511 Section 25.1511 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT... Limitations § 25.1511 Flap extended speed. The established flap extended speed V FE must be established so...
Reconstruction of pressure sores with perforator-based propeller flaps.
Jakubietz, Rafael G; Jakubietz, Danni F; Zahn, Robert; Schmidt, Karsten; Meffert, Rainer H; Jakubietz, Michael G
2011-03-01
Perforator flaps have been successfully used for reconstruction of pressure sores. Although V-Y advancement flaps approximate debrided wound edges, perforator-based propeller flaps allow rotation of healthy tissue into the defect. Perforator-based propeller flaps were planned in 13 patients. Seven pressure sores were over the sacrum, five over the ischial tuberosity, and one on the tip of the scapula. Three patients were paraplegic, six were bedridden, and five were ambulatory. In three patients, no perforators were found. In 10 patients, propeller flaps were transferred. In two patients, total flap necrosis occurred, which was reconstructed with local advancement flaps. In two cases, a wound dehiscence occurred and had to be revised. One hematoma required evacuation. No further complications were noted. No recurrence at the flap site occurred. Local perforator flaps allow closure of pressure sores without harvesting muscle. The propeller version has the added benefit of transferring tissue from a distant site, avoiding reapproximation of original wound edges. Twisting of the pedicle may cause torsion and venous obstruction. This can be avoided by dissecting a pedicle of at least 3 cm. Propeller flaps are a safe option for soft tissue reconstruction of pressure sores. © Thieme Medical Publishers.
Reconstruction Using Locoregional Flaps for Large Skull Base Defects.
Hatano, Takaharu; Motomura, Hisashi; Ayabe, Shinobu
2015-06-01
We present a modified locoregional flap for the reconstruction of large anterior skull base defects that should be reconstructed with a free flap according to Yano's algorithm. No classification of skull base defects had been proposed for a long time. Yano et al suggested a new classification in 2012. The lb defect of Yano's classification extends horizontally from the cribriform plate to the orbital roof. According to Yano's algorithm for subsequent skull base reconstructive procedures, a lb defect should be reconstructed with a free flap such as an anterolateral thigh free flap or rectus abdominis myocutaneous free flap. However, our modified locoregional flap has also enabled reconstruction of lb defects. In this case series, we used a locoregional flap for lb defects. No major postoperative complications occurred. We present our modified locoregional flap that enables reconstruction of lb defects.
Rozen, Warren M; Fox, Carly M; Leong, James; Morsi, Adel
2013-11-01
Multiple variations of the musculocutaneous trapezius flap have been described, each of which use a single composite musculocutaneous unit in their designs. The limitation of such designs is the ability to use the components in a 3-dimensional manner, with only 1 vector existing in the geometry of the musculocutaneous unit. A review of the literature was undertaken with regard to designs of the musculocutaneous trapezius flap, and we present a new technique for flap design. With identification of individual perforators to each of the muscle and fasciocutaneous portions of the trapezius flap, the 2 components can act in a chimeric fashion, able to fill both a deep and complex 3-dimensional space while covering the wound with robust skin. A range of flap designs have been described, including transverse, oblique, and vertical skin paddles accompanying the trapezius muscle. We describe a technique with which a propeller-style skin paddle based on a cutaneous perforator can be raised in any orientation with respect to the underlying muscle. In a presented case, separation of the muscular and fasciocutaneous components of the trapezius flap was able to obliterate dead space around exposed cervicothoracic spinal metalwork and obtain robust wound closure in a patient with previous radiotherapy. This concomitant use of a muscle and fasciocutaneous perforator flap based on a single perforator, a so-called chimeric perforator flap, is a useful modification to trapezius musculocutaneous flap design.
14 CFR 23.1511 - Flap extended speed.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Flap extended speed. 23.1511 Section 23.1511 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT... Information § 23.1511 Flap extended speed. (a) The flap extended speed V FE must be established so that it is...
14 CFR 23.1511 - Flap extended speed.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Flap extended speed. 23.1511 Section 23.1511 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT... Information § 23.1511 Flap extended speed. (a) The flap extended speed V FE must be established so that it is...
14 CFR 23.1511 - Flap extended speed.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Flap extended speed. 23.1511 Section 23.1511 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT... Information § 23.1511 Flap extended speed. (a) The flap extended speed V FE must be established so that it is...
14 CFR 23.1511 - Flap extended speed.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Flap extended speed. 23.1511 Section 23.1511 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT... Information § 23.1511 Flap extended speed. (a) The flap extended speed V FE must be established so that it is...
14 CFR 23.1511 - Flap extended speed.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Flap extended speed. 23.1511 Section 23.1511 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT... Information § 23.1511 Flap extended speed. (a) The flap extended speed V FE must be established so that it is...
Long-Term Follow-Up of Flap Prefabrication in Facial Reconstruction.
Wang, Weixin; Zhao, Muxin; Tang, Yong; Chen, Wen; Yang, Zhe; Ma, Ning; Xu, Lisi; Feng, Jun; Li, Yangqun
2017-07-01
Flap prefabrication is to turn a random flap into an axial flap by transferring a vascular pedicle. In the past 13 years, we have prefabricated 20 flaps in 20 patients by the superficial temporal artery and its concomitant veins. Typically, a 50- to 800-mL tissue expander was implanted in the donor site. After flap maturation, the prefabricated flap was raised and transferred locally to cover the large defect on the face. All the cases were followed up regularly. The patients' age were between 3 and 27 years, the size of the flaps were between 3.5 × 5.5 cm and 13 × 15 cm, the superficial temporal artery length was between 10 and 15 cm. All flaps were transferred successfully: 10 of the flaps had venous congestion, partial epidermis exfoliation and flap necrosis occurred in 4 flaps. All cases were followed up for at least 1 year, the longest follow-up period was 9 years. Long-term follow-up results showed the prefabricated flap survived in good condition and had a satisfactory outcome. Because flap prefabrication is practical, and long-term follow-ups have proved its preferable characters and stability, it is a fine method for large area facial reconstructions.
Thoma, Achilleas; Veltri, Karen; Khuthaila, Dana; Rockwell, Gloria; Duku, Eric
2004-05-01
This study compared the deep inferior epigastric perforator (DIEP) flap and the free transverse rectus abdominis myocutaneous (TRAM) flap in postmastectomy reconstruction using a cost-effectiveness analysis. A decision analytic model was used. Medical costs associated with the two techniques were estimated from the Ontario Ministry of Health Schedule of Benefits for 2002. Hospital costs were obtained from St. Joseph's Healthcare, a university teaching hospital in Hamilton, Ontario, Canada. The utilities of clinically important health states related to breast reconstruction were obtained from 32 "experts" across Canada and converted into quality-adjusted life years. The probabilities of these various clinically important health states being associated with the DIEP and free TRAM flaps were obtained after a thorough review of the literature. The DIEP flap was more costly than the free TRAM flap ($7026.47 versus $6508.29), but it provided more quality-adjusted life years than the free TRAM flap (28.88 years versus 28.53 years). The baseline incremental cost-utility ratio was $1464.30 per quality-adjusted life year, favoring adoption of the DIEP flap. Sensitivity analyses were performed by assuming that the probabilities of occurrence of hernia, abdominal bulging, total flap loss, operating room time, and hospital stay were identical with the DIEP and free TRAM techniques. By assuming that the probability of postoperative hernia for the DIEP flap increased from 0.008 to 0.054 (same as for TRAM flap), the incremental cost-utility ratio changed to $1435.00 per quality-adjusted life year. A sensitivity analysis was performed for the complication of hernia because the DIEP flap allegedly diminishes this complication. Increasing the probability of abdominal bulge from 0.041 to 0.103 for the DIEP flap changed the ratio to $2731.78 per quality-adjusted life year. When the probability of total flap failure was increased from 0.014 to 0.016, the ratio changed to $1384.01 per
NASA Technical Reports Server (NTRS)
Mendenhall, M. R.; Goodwin, F. K.; Spangler, S. B.
1976-01-01
A vortex lattice lifting-surface method is used to model the wing and multiple flaps. Each lifting surface may be of arbitrary planform having camber and twist, and the multiple-slotted trailing-edge flap system may consist of up to ten flaps with different spans and deflection angles. The engine wakes model consists of a series of closely spaced vortex rings with circular or elliptic cross sections. The rings are normal to a wake centerline which is free to move vertically and laterally to accommodate the local flow field beneath the wing and flaps. The two potential flow models are used in an iterative fashion to calculate the wing-flap loading distribution including the influence of the waves from up to two turbofan engines on the semispan. The method is limited to the condition where the flow and geometry of the configurations are symmetric about the vertical plane containing the wing root chord. The calculation procedure starts with arbitrarily positioned wake centerlines and the iterative calculation continues until the total configuration loading converges within a prescribed tolerance. Program results include total configuration forces and moments, individual lifting-surface load distributions, including pressure distributions, individual flap hinge moments, and flow field calculation at arbitrary field points.
Lift production through asymmetric flapping
NASA Astrophysics Data System (ADS)
Jalikop, Shreyas; Sreenivas, K. R.
2009-11-01
At present, there is a strong interest in developing Micro Air Vehicles (MAV) for applications like disaster management and aerial surveys. At these small length scales, the flight of insects and small birds suggests that unsteady aerodynamics of flapping wings can offer many advantages over fixed wing flight, such as hovering-flight, high maneuverability and high lift at large angles of attack. Various lift generating mechanims such as delayed stall, wake capture and wing rotation contribute towards our understanding of insect flight. We address the effect of asymmetric flapping of wings on lift production. By visualising the flow around a pair of rectangular wings flapping in a water tank and numerically computing the flow using a discrete vortex method, we demonstrate that net lift can be produced by introducing an asymmetry in the upstroke-to-downstroke velocity profile of the flapping wings. The competition between generation of upstroke and downstroke tip vortices appears to hold the key to understanding this lift generation mechanism.
Park, Jun Hyung; Eun, Suk Chan; Lee, Jong Hoon; Hong, Sung Hee; Kim, Chin Whan
2012-01-01
We experienced satisfactory outcomes by synchronously transplanting an artery and vein using an anterolateral thigh flap pedicle between the vascular pedicle and recipient vessel of a flap for scalp reconstruction. A 45-year-old man developed a subdural hemorrhage due to a fall injury. In this patient, the right temporal cranium was missing and the patient had 4×3 cm and 6×5 cm scalp defects. We planned a scalp reconstruction using a latissimus dorsi free flap. Intraoperatively, there was a severe injury to the right superficial temporal vessel because of previous neurosurgical operations. A 15 cm long pedicle defect was needed to reach the recipient facial vessels. For the vascular graft, the descending branch of the lateral circumflex femoral artery and two venae comitantes were harvested. The flap survived well and the skin graft was successful with no notable complications. When an interposition graft is needed in the reconstruction of the head and neck region for which mobility is mandatory to a greater extent, a sufficient length of graft from an anterolateral flap pedicle could easily be harvested. Thus, this could contribute to not only resolving the disadvantages of a venous graft but also to successfully performing a vascular anastomosis. PMID:22783493
Reconstruction of Anterolateral Thigh Defects Using Perforator-Based Propeller Flaps.
Iida, Takuya; Yoshimatsu, Hidehiko; Koshima, Isao
2017-10-01
Usually, anterolateral thigh (ALT) defects with width more than 8 cm cannot be closed directly. Although several methods of using local flaps exist, flap mobility of these methods is limited. We introduced a perforator-based propeller flap for such reconstruction. Their maximal mobility, which minimizes their size, is their greatest advantage. In addition, we present our technical refinements including double-axes propeller flap, the use of indocyanine green real-time angiography, and supercharged propeller flap for safer flap transfer. Seven patients underwent perforator-based propeller flap reconstruction of ALT defects. Flaps were designed cranial or caudal to the defect according to the perforator locations. To maximize mobility, flaps were designed so that the perforator was located at the periphery and closer to the defect. After rotating the flap to the defect, indocyanine green angiography was performed to determine the need for supercharge. In all cases, all flaps survived completely. Defect size ranged from 12 × 11 cm to 18 × 16 cm, and flap size ranged from 7 × 5 cm to 15 × 7 cm. The number of perforators in the flap was 1 in 3 cases and 2 in 4 cases. Supercharging was performed in 3 cases. Donor-site complications, including gait disturbance, were not observed. This method achieves ALT defect closure with minimal donor-site morbidity and can provide prompt and aesthetically acceptable results. Indocyanine green real-time angiography and supercharging technique are also useful for safer and reliable flap transfer.
Flow field of flexible flapping wings
NASA Astrophysics Data System (ADS)
Sallstrom, Erik
The agility and maneuverability of natural fliers would be desirable to incorporate into engineered micro air vehicles (MAVs). However, there is still much for engineers to learn about flapping flight in order to understand how such vehicles can be built for efficient flying. The goal of this study is to develop a methodology for capturing high quality flow field data around flexible flapping wings in a hover environment and to interpret it to gain a better understanding of how aerodynamic forces are generated. The flow field data was captured using particle image velocimetry (PIV) and required that measurements be taken around a repeatable flapping motion to obtain phase-averaged data that could be studied throughout the flapping cycle. Therefore, the study includes the development of flapping devices with a simple repeatable single degree of freedom flapping motion. The acquired flow field data has been examined qualitatively and quantitatively to investigate the mechanisms behind force production in hovering flight and to relate it to observations in previous research. Specifically, the flow fields have been investigated around a rigid wing and several carbon fiber reinforced flexible membrane wings. Throughout the whole study the wings were actuated with either a sinusoidal or a semi-linear flapping motion. The semi-linear flapping motion holds the commanded angular velocity nearly constant through half of each half-stroke while the sinusoidal motion is always either accelerating or decelerating. The flow fields were investigated by examining vorticity and vortex structures, using the Q criterion as the definition for the latter, in two and three dimensions. The measurements were combined with wing deflection measurements to demonstrate some of the key links in how the fluid-structure interactions generated aerodynamic forces. The flow fields were also used to calculate the forces generated by the flapping wings using momentum balance methods which yielded
Ju, Jihui; Li, Lei; Zhou, Rong; Hou, Ruixing
2018-05-18
To evaluate the clinical efficacy and safety of latissimus dorsi myocutaneous flap (stage I) combined with iliac bone flap (stage II) in the treatment of chronic osteomyelitis of the lower extremity. Clinical data of 18 patients undergoing latissimus dorsi myocutaneous flap in combination with iliac bone flap grafting were retrospectively analyzed. Among them, 2 patients developed chronic osteomyelitis of the lower segment of the femur, 4 were diagnosed with chronic osteomyelitis of the tibial plateau, and 12 with chronic osteomyelitis of the lower segment of the tibia. All the latissimus dorsi myocutaneous flaps survived in 18 patients. After the corresponding surgery, primary wound healing was achieved in 11 patients, and delayed wound healing was obtained in 7 cases. All wounds were completely healed with postoperative 2 months. Following the iliac bone flap grafting, primary would healing was accomplished in all cases. All dorsal window chambers survived. The bone defects were properly restored within 4-12 postoperative months. Functional training was performed after removal of the internal and external fixators. Postoperative follow-up was endured from 6 months to 10 years. All patients were satisfied with the bone healing and flap texture without the incidence of osteomyelitis and sinus tract. No contraction was observed in the grafting area of 2 patients receiving latissimus dorsi myocutaneous flap grafting. Residual linear scars were noted in the dorsal and iliac donor sites. Combined usage of stage I latissimus dorsi myocutaneous flap and stage II iliac bone flap grafting is an efficacious and safe surgical technique in clinical practice.
Lim, Hyoseob; Han, Dae Hee; Lee, Il Jae; Park, Myong Chul
2014-03-01
Extensive degloving injuries of the extremities usually result in necrosis of the flap, necessitating comprehensive skin grafting. Provided there is a sufficient tool to evaluate flap viability, full-thickness skin can be used from a nonviable avulsed flap. We used a Wood's lamp to determine the viability of avulsed flaps in the operation field after intravenous injection of fluorescein dye. We experienced 13 cases during 16 months. Fifteen minutes after the intravenous injection of fluorescein dye, the avulsed skin flaps were examined and non-fluorescent areas were marked under Wood's lamp illumination. The marked area was defatted for full-thickness skin grafting. The fluorescent areas were sutured directly without tension. The non-fluorescent areas were covered by defatted skin. Several days later, there was soft tissue necrosis within the flap area. We measured necrotic area and revised the flap. Among all the cases, necrotic area was 21.3% of the total avulsed area. However, if we exclude three cases, one of a carelessly managed patient and two cases of the flaps were inappropriately applied, good results were obtained, with a necrotic area of only 8.4%. Eight patients needed split-thickness skin grafts, and heel pad reconstruction was performed with free flap. A full-thickness skin graft from an avulsed flap is a good method for addressing aesthetic concerns without producing donor site morbidity. Fluorescein dye is a useful, simple, and cost-effective tool for evaluating flap viability. Avulsed flap injuries can be managed well with Wood's lamp illumination and a full-thickness skin graft.
Shi, Pengju; Zhang, Wenlong; Zhao, Gang; Li, Zhigang; Zhao, Shaoping; Zhang, Tieshan
2015-07-01
To investigate the effectiveness of dorsalis pedis flap series-parallel big toe nail composite tissue flap in the repairment of hand skin of degloving injury with tumb defect. Between March 2009 and June 2013, 8 cases of hand degloving injury with thumb defect caused by machine twisting were treated. There were 7 males and 1 female with the mean age of 36 years (range, 26-48 years). Injury located at the left hand in 3 cases and at the right hand in 5 cases. The time from injury to hospitalization was 1.5-4.0 hours (mean, 2.5 hours). The defect area was 8 cm x 6 cm to 15 cm x 1 cm. The thumb defect was rated as degree I in 5 cases and as degree II in 3 cases. The contralateral dorsal skin flap (9 cm x 7 cm to 10 cm x 8 cm) combined with ipsilateral big toe nail composite tissue flap (2.5 cm x 1.8 cm to 3.0 cm x 2.0 cm) was used, including 3 parallel anastomosis flaps and 5 series anastomosis flaps. The donor site of the dorsal flap was repaired with thick skin grafts, the stumps wound was covered with tongue flap at the shank side of big toe. Vascular crisis occurred in 1 big toe nail composite tissue flap, margin necrosis occurred in 2 dorsalis pedis flap; the other flaps survived, and primary healing of wound was obtained. The grafted skin at dorsal donor site all survived, skin of hallux toe stump had no necrosis. Eight cases were followed up 4-20 months (mean, 15.5 months). All flaps had soft texture and satisfactory appearance; the cutaneous sensory recovery time was 4-7 months (mean, 5 months). At 4 months after operation, the two-point discrimination of the thumb pulp was 8-10 mm (mean, 9 mm), and the two-point discrimination of dorsal skin flap was 7-9 mm (mean, 8.5 mm). According to Society of Hand Surgery standard for the evaluation of upper part of the function, the results were excellent in 4 cases, good in 3 cases, and fair in 1 case. The donor foot had normal function. Dorsalis pedis flap series-parallel big toe nail composite tissue flap is an ideal
Bozkurt, Mehmet; Kapi, Emin; Kuvat, Samet Vasfi; Selçuk, Caferi Tayyar
2012-11-01
Tissue losses within the nose due to various reasons result in the loss of normal anatomy and function. The external nasal valve area is one of the most important functional components of the nose. The columella, lobule, nostril, and alar region are among the components forming the external nasal valve area. Deformities of the nostrils are among the most frequently observed features that interfere with the functional anatomy of the nose. Malformations of the nostrils often emerge subsequent to cleft lip repairs. Stenoses are a common type of pathology among nostril deformities. In cases where a stenosis has formed, breathing problems and developmental anomalies may occur. In the patient with nostril stenosis presented in this report, there was a serious alar collapse and contracture subsequent to a cleft lip repair. In order to repair the nostril stenosis, a "boomerang flap" was chosen. This boomerang flap was used in combination with a nasolabial flap, a vestibular rotation flap, and a conchal cartilage graft to achieve a satisfactory repair.
Triple flap technique for vulvar reconstruction.
Mercut, R; Sinna, R; Vaucher, R; Giroux, P A; Assaf, N; Lari, A; Dast, S
2018-04-09
Perineal defects are encountered ever more frequently, in the treatment of vulvar cancers or abdominoperineal resection. The surgical treatment of vulvar cancer leads to significant skin defect. The aim of the reconstruction is not to provide volume but rather to resurface perineum. We propose a new solution to cover the extensive skin defect remaining after excision. We report 3 patients who underwent large excision for vulvar cancer, with lymph node dissection. For reconstruction, we performed 3 advancement flaps. Two V-Y flaps cantered on the infra-gluteal folds and based on pudendal perforator arteries were used to cover the postero-lateral parts of the defect. The third advancement flap from the superior aspect of the defect was a Y-V Mons pubis flap. The defects were successfully covered by the 3 flap technique. The first patient suffered a non-union that slowly healed by secondary intention. For the other cases, we used the same technique, but applied negative pressure wound therapy on the sutures, with excellent results. The 3 flap technique is a simple and reliable method and the donor site morbidity is minimal. It can be realised without changing the position of the patient after tumour excision, and does not require delicate perforator dissection. This surgical option can be easily applied, allowing better management of these cases. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
"Internet of Things" Real-Time Free Flap Monitoring.
Kim, Sang Hun; Shin, Ho Seong; Lee, Sang Hwan
2018-01-01
Free flaps are a common treatment option for head and neck reconstruction in plastic reconstructive surgery, and monitoring of the free flap is the most important factor for flap survival. In this study, the authors performed real-time free flap monitoring based on an implanted Doppler system and "internet of things" (IoT)/wireless Wi-Fi, which is a convenient, accurate, and efficient approach for surgeons to monitor a free flap. Implanted Doppler signals were checked continuously until the patient was discharged by the surgeon and residents using their own cellular phone or personal computer. If the surgeon decided that a revision procedure or exploration was required, the authors checked the consumed time (positive signal-to-operating room time) from the first notification when the flap's status was questioned to the determination for revision surgery according to a chart review. To compare the efficacy of real-time monitoring, the authors paired the same number of free flaps performed by the same surgeon and monitored the flaps using conventional methods such as a physical examination. The total survival rate was greater in the real-time monitoring group (94.7% versus 89.5%). The average time for the real-time monitoring group was shorter than that for the conventional group (65 minutes versus 86 minutes). Based on this study, real-time free flap monitoring using IoT technology is a method that surgeon and reconstruction team can monitor simultaneously at any time in any situation.
Pressure Available for Cooling with Cowling Flaps
NASA Technical Reports Server (NTRS)
Stickle, George W; Naiman, Irven; Crigler, John L
1941-01-01
Report presents the results of a full-scale investigation conducted in the NACA 20-foot tunnel to determine the pressure difference available for cooling with cowling flaps. The flaps were applied to an exit slot of smooth contour at 0 degree flap angle. Flap angles of 0 degree, 15 degrees, and 30 degrees were tested. Two propellers were used; propeller c which has conventional round blade shanks and propeller f which has airfoil sections extending closer to the hub. The pressure available for cooling is shown to be a direct function of the thrust disk-loading coefficient of the propeller.
Flap Edge Noise Reduction Fins
NASA Technical Reports Server (NTRS)
Khorrami, Mehdi R. (Inventor); Choudhan, Meelan M. (Inventor)
2015-01-01
A flap of the type that is movably connected to an aircraft wing to provide control of an aircraft in flight includes opposite ends, wherein at least a first opposite end includes a plurality of substantially rigid, laterally extending protrusions that are spaced apart to form a plurality of fluidly interconnected passageways. The passageways have openings adjacent to upper and lower sides of the flap, and the passageways include a plurality of bends such that high pressure fluid flows from a high pressure region to a low pressure region to provide a boundary condition that inhibits noise resulting from airflow around the end of the flap.
Coarse-grained models for interacting, flapping swimmers
NASA Astrophysics Data System (ADS)
Oza, Anand; Ristroph, Leif; Shelley, Michael; Courant Institute Applied Math Lab Collaboration
2016-11-01
We present the results of a theoretical investigation into the dynamics of interacting flapping swimmers. Our study is motivated by ongoing experiments in the NYU Applied Math Lab, in which freely-translating, heaving airfoils interact hydrodynamically to choose their relative positions and velocities. We develop a discrete dynamical system in which flapping swimmers shed point vortices during each flapping cycle, which in turn exert forces on the swimmers. We present a framework for finding exact solutions to the evolution equations and for assessing their stability, giving physical insight into the preference for certain observed "schooling states". The model may be extended to arrays of flapping swimmers, and configurations in which the swimmers' flapping frequencies are incommensurate. Generally, our results indicate how hydrodynamics may mediate schooling and flocking behavior in biological contexts. A. Oza acknowledges the support of the NSF Mathematical Sciences Postdoctoral Fellowship.
Zhou, Xiao; Wang, Jin; Qiang, Li; Rui, Yongjun; Xue, Mingyu
2018-04-01
The anterolateral thigh (ALT) flap plays an essential part in plastic and reconstructive surgery. However, repair of the anterolateral donor site has not been the focus of the clinicians.To assess the clinical value and feasibility of using a modified anteromedial thigh (AMT) perforator flap for repairing the ALT free flap donor site.In this retrospective study, 16 ALT flaps were transferred to resurface large soft-tissue defects (ranged from 7 × 5 to 13 × 8 cm) in the foot or hand from June 2012 to March 2013. The donor sites were repaired with an advancement flap pedicled with an AMT perforator. Sensation within the advancement flap, return-to-work (RTW) time, the aesthetic appearance of the donor sites, and functional recovery were measured.All 15 flaps survived completely without necrosis. One flap developed partial necrosis in the tip but healed with dressing changes after 1 week. The medain follow-up period was 3.5 months (range, 3-6 months). The average median time was 9.5 weeks (range 8-13 weeks). There was no numbness of the advancement flap. Additionally, there was no specific complication at both the recipient and donor sites. Thigh quadriceps muscle strength and activities of the knee were normal. All patients were satisfied with the aesthetic outcome postoperatively at the 3-month to 6-month follow-up.The modified advancement flap pedicled with an AMT perforator is an ideal option for repairing the anterolateral donor site.
Flap Edge Aeroacoustic Measurements and Predictions
NASA Technical Reports Server (NTRS)
Brooks, Thomas F.; Humphreys, William M., Jr.
2000-01-01
An aeroacoustic model test has been conducted to investigate the mechanisms of sound generation on high-lift wing configurations. This paper presents an analysis of flap side-edge noise, which is often the most dominant source. A model of a main element wing section with a half-span flap was tested at low speeds of up to a Mach number of 0.17, corresponding to a wing chord Reynolds number of approximately 1.7 million. Results are presented for flat (or blunt), flanged, and round flap-edge geometries, with and without boundary-layer tripping, deployed at both moderate and high flap angles. The acoustic database is obtained from a Small Aperture Directional Array (SADA) of microphones, which was constructed to electronically steer to different regions of the model and to obtain farfield noise spectra and directivity from these regions. The basic flap-edge aerodynamics is established by static surface pressure data, as well as by Computational Fluid Dynamics (CFD) calculations and simplified edge flow analyses. Distributions of unsteady pressure sensors over the flap allow the noise source regions to be defined and quantified via cross-spectral diagnostics using the SADA output. It is found that shear layer instability and related pressure scatter is the primary noise mechanism. For the flat edge flap, two noise prediction methods based on unsteady surface pressure measurements are evaluated and compared to measured noise. One is a new causality spectral approach developed here. The other is a new application of an edge-noise scatter prediction method. The good comparisons for both approaches suggest that much of the physics is captured by the prediction models. Areas of disagreement appear to reveal when the assumed edge noise mechanism does not fully define the noise production. For the different edge conditions, extensive spectra and directivity are presented. Significantly, for each edge configuration, the spectra for different flow speeds, flap angles, and
Flap Edge Aeroacoustic Measurements and Predictions
NASA Technical Reports Server (NTRS)
Brooks, Thomas F.; Humphreys, William M., Jr.
2000-01-01
An aeroacoustic model test has been conducted to investigate the mechanisms of sound generation on high-lift wing configurations. This paper presents an analysis of flap side-edge noise, which is often the most dominant source. A model of a main element wing section with a half-span flap was tested at low speeds of up to a Mach number of 0.17, corresponding to a wing chord Reynolds number of approximately 1.7 million. Results are presented for flat (or blunt), flanged, and round flap-edge geometries, with and without boundary-layer tripping, deployed at both moderate and high flap angles. The acoustic database is obtained from a Small Aperture Directional Array (SADA) of microphones, which was constructed to electronically steer to different regions of the model and to obtain farfield noise spectra and directivity from these regions. The basic flap-edge aerodynamics is established by static surface pressure data, as well as by Computational Fluid Dynamics (CFD) calculations and simplified edge flow analyses. Distributions of unsteady pressure sensors over the flap allow the noise source regions to be defined and quantified via cross-spectral diagnostics using the SADA output. It is found that shear layer instability and related pressure scatter is the primary noise mechanism. For the flat edge flap, two noise prediction methods based on unsteady-surface-pressure measurements are evaluated and compared to measured noise. One is a new causality spectral approach developed here. The other is a new application of an edge-noise scatter prediction method. The good comparisons for both approaches suggest that much of the physics is captured by the prediction models. Areas of disagreement appear to reveal when the assumed edge noise mechanism does not fully define, the noise production. For the different edge conditions, extensive spectra and directivity are presented. Significantly, for each edge configuration, the spectra for different flow speeds, flap angles, and
Classification and Microvascular Flap Selection for Anterior Cranial Fossa Reconstruction.
Vargo, James D; Przylecki, Wojciech; Camarata, Paul J; Andrews, Brian T
2018-05-18
Microvascular reconstruction of the anterior cranial fossa (ACF) creates difficult challenges. Reconstructive goals and flap selection vary based on the defect location within the ACF. This study evaluates the feasibility and reliability of free tissue transfer for salvage reconstruction of low, middle, and high ACF defects. A retrospective review was performed. Reconstructions were anatomically classified as low (anterior skull base), middle (frontal bar/sinus), and high (frontal bone/soft tissue). Subjects were evaluated based on pathologic indication and goal, type of flap used, and complications observed. Eleven flaps in 10 subjects were identified and anatomic sites included: low ( n = 5), middle ( n = 3), and high ( n = 3). Eight of 11 reconstructions utilized osteocutaneous flaps including the osteocutaneous radial forearm free flap (OCRFFF) ( n = 7) and fibula ( n = 1). Other reconstructions included a split calvarial graft wrapped within a temporoparietal fascia free flap ( n = 1), latissimus myocutaneous flap ( n = 1), and rectus abdominis myofascial flap ( n = 1). All 11 flaps were successful without microvascular compromise. No complications were observed in the high and middle ACF defect groups. Two of five flaps in the low defect group using OCRFFF flaps failed to achieve surgical goals despite demonstrating healthy flaps upon re-exploration. Complications included persistent cerebrospinal fluid leak ( n = 1) and pneumocephalus ( n = 1), requiring flap repositioning in one subject and a second microvascular flap in the second subject to achieve surgical goals. In our experience, osteocutaneous flaps (especially the OCRFFF) are preferred for complete autologous reconstruction of high and middle ACF defects. Low skull base defects are more difficult to reconstruct, and consideration of free muscle flaps (no bone) should be weighed as an option in this anatomic area. Thieme Medical Publishers
Temporalis myo-osseous flap: an experimental study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Antonyshyn, O.; Colcleugh, R.G.; Hurst, L.N.
1986-03-01
The present paper investigates the anatomy and vascularization of the temporalis myo-osseous flap. This is a calvarial bone flap that employs temporalis muscle and its distal pericranial extension as a pedicle. In six human cadavers the flap was raised as an island on the anterior deep temporal artery after transecting the zygomatic arch and coronoid process. Maximal mobilization was thus obtained, allowing rotation of the flap into the mouth for intraoral reconstruction. The arc of rotation and potential surgical applications were noted. A comparative study of the temporalis myo-osseous flap and free calvarial bone graft was then conducted in amore » rabbit model. Vascularization of the calvarial bone flap was confirmed by technetium scintigraphy performed on the first postoperative day. The uptake of fluorochrome labels immediately after transfer verified the adequacy of the periosteal circulation in maintaining viability and new osteoid formation throughout the full thickness of calvarial bone. The transplantation of free calvarial bone grafts was followed by necrosis of most cellular elements. This was demonstrated by an absence of fluorochrome uptake up to 19 days postoperatively and a predominance of empty lacunae and nonviable marrow.« less
The clinical application of anterolateral thigh flap.
Lee, Yao-Chou; Chiu, Haw-Yen; Shieh, Shyh-Jou
2011-01-01
The anterolateral thigh flap can provide a large skin paddle nourished by a long and large-caliber pedicle and can be harvested by two-team work. Most importantly, the donor-site morbidity is minimal. However, the anatomic variations decreased its popularity. By adapting free-style flap concepts, such as preoperative mapping of the perforators and being familiar with retrograde perforator dissection, this disadvantage had been overcome gradually. Furthermore, several modifications widen its clinical applications: the fascia lata can be included for sling or tendon reconstruction, the bulkiness could be created by including vastus lateralis muscle or deepithelization of skin flap, the pliability could be increased by suprafascial dissection or primary thinning, the pedicle length could be lengthening by proximally eccentric placement of the perforator, and so forth. Combined with these technical and conceptual advancements, the anterolateral thigh flap has become the workhorse flap for soft-tissue reconstructions from head to toe.
Reconstruction of eyelids with Washio flap in anophthalmia.
Tvrdek, M; Kozák, J
2014-01-01
The authors present a case report of a patient with anophthalmia in whom retroauriculo-temporal flap (Washio flap) was used for reconstruction of eyelids. This flap, which is mostly used for reconstructions of nasal defects, was not used in this way according to available literature.
Pectoralis myocutaneous flap for salvage of necrotic wounds
DOE Office of Scientific and Technical Information (OSTI.GOV)
Price, J.C.; Davis, R.K.; Koltai, P.J.
1985-02-01
The authors have utilized six pectoralis major myocutaneous flaps in attempts to salvage extensive necrotic wounds of the pharynx and neck. The flap was employed in the following situations: massive necrosis of the entire neck skin with both carotid artery systems exposed, radiation necrosis of the neck skin with exposure of carotid artery, dehiscence of gastric pull-up from pharynx with resultant carotid exposure, failed trapezius flap in a radionecrotic oral cavity, and two cases of pharyngocutaneous fistula with extensive soft tissue necrosis. These flaps achieved healing in all cases. One death occurred 3 weeks following complete cutaneous healing secondary tomore » a ruptured carotid pseudoaneurysm. One flap underwent total skin loss but the entirety of the muscle survived and the fistula was successfully closed with the back of the muscle being subsequently skin grafted. One case of dehiscence of the flap from oral mucosa resulted in a minor exposure of mandible with limited osteoradionecrosis controlled by topical means. This flap has performed extremely well in these precarious and difficult situations that previously may not have been salvageable. It has also been effective in abbreviating the required hospitalization and wound care. The authors conclude that the pectoralis myocutaneous flap should be the primary choice for the management of extensive postsurgical wound necrosis.« less
Calf Perforator Flaps: A Freestyle Solution for Oral Cavity Reconstruction.
Molina, Alexandra R; Citron, Isabelle; Chinaka, Fungayi; Cascarini, Luke; Townley, William A
2017-02-01
Reconstruction of oral cavity defects requires a thin, pliable flap for optimal functional results. Traditional flap choices are imperfect: the anterolateral thigh flap is excessively thick, whereas the radial forearm flap has a poor donor site. The authors therefore favor calf perforator flaps such as the medial sural artery perforator flap to provide thin tissue with an acceptable donor site. This two-part study aims to demonstrate their suitability for intraoral reconstruction. In the radiologic part of the study, the authors compared thigh and calf tissue thickness by examining lower limb computed tomographic scans of 100 legs. For their clinical study, they collected data prospectively on 20 cases of oral cavity reconstruction using calf perforator flaps. The mean thickness of the calf tissue envelope was significantly less than that of the thigh (8.4 mm compared with 17 mm) based on computed tomographic analysis. In the clinical study, a medial sural artery perforator was used in the majority of cases (17 of 20). The mean pedicle length was 10.2 cm and the mean time to raise a flap was 85 minutes. There were no flap losses. One patient was returned to the operating room for management of late hematoma and wound dehiscence. Calf perforator flaps provide ideal tissue for intraoral reconstruction and are significantly thinner than anterolateral thigh flaps. In addition to medial sural artery perforator flaps, the authors raised both sural and soleal artery perforator flaps in this series. Opportunistic use of the calf donor site allows the harvest of thin tissue with minimal donor-site morbidity. Therapeutic, IV.
New method for maximum mobilization of temporalis muscle flap.
Masic, Tarik; Babajic, Emina; Dervisevic, Almir; Hassouba, Mahmoud
2012-01-01
Pedicled temporalis muscle flap presenting a good flap for closing large craniofacial defects. Careful surgeons usually do not mobilize temporalis muscle flap enough to make appropriate use, fully closure, especially if defect exceeds the median line. Temporalis flap was used in 16 patients, ages ranged between 12 and 76. In all cases defect reconstruction was done by useing new method of extending standard temporal muscle flap. During surgical procedure it is very important to keep periosteal elevator in close contact with the bone. Then, there is no risk for pedicle injury. After vascular pedicle is identified elevating temporal muscle has to be continued by releasing the muscle insertion from the coronoid process. By this way, flap length and arc of rotation is increased. The flap remained viable in all instances. Most of the patients experienced no perioperative complications. There was no major complications or mortality as a result of performed procedures. With this division, flap length was increased at least 2 cm wich is enough for covering defects crossing the midline. Instead of using bilateral temporalis muscle flaps for defect closure, unilateral is sufficient. With this extension of the pedicle length now rotation point is not at the level of the zygomatic arch but lower part mandibular neck.
Flexible wings in flapping flight
NASA Astrophysics Data System (ADS)
Moret, Lionel; Thiria, Benjamin; Zhang, Jun
2007-11-01
We study the effect of passive pitching and flexible deflection of wings on the forward flapping flight. The wings are flapped vertically in water and are allowed to move freely horizontally. The forward speed is chosen by the flapping wing itself by balance of drag and thrust. We show, that by allowing the wing to passively pitch or by adding a flexible extension at its trailing edge, the forward speed is significantly increased. Detailed measurements of wing deflection and passive pitching, together with flow visualization, are used to explain our observations. The advantage of having a wing with finite rigidity/flexibility is discussed as we compare the current results with our biological inspirations such as birds and fish.
Application of multidetector-row computed tomography in propeller flap planning.
Ono, Shimpei; Chung, Kevin C; Hayashi, Hiromitsu; Ogawa, Rei; Takami, Yoshihiro; Hyakusoku, Hiko
2011-02-01
The propeller flap is defined as (1) being island-shaped, (2) having an axis that includes the perforators, and (3) having the ability to be rotated around an axis. The advantage of the propeller flap is that it is a pedicle flap that can be applied to cover defects located at the distal ends of the extremities. The specific aims of the authors' study were (1) to evaluate the usefulness of multidetector-row computed tomography in the planning of propeller flaps and (2) to present a clinical case series of propeller flap reconstructions that were planned preoperatively using multidetector-row computed tomography. The authors retrospectively analyzed all cases between April of 2007 and April of 2010 at Nippon Medical School Hospital in Tokyo, where multidetector-row computed tomography was used preoperatively to plan surgical reconstructions using propeller flaps. Thirteen patients underwent 16 flaps using the propeller flap technique. The perforators were identified accurately by multidetector-row computed tomography preoperatively in all cases. This is the first report describing the application of multidetector-row computed tomography in the planning of propeller flaps. Multidetector-row computed tomography is superior to other imaging methods because it demonstrates more precisely the perforator's position and subcutaneous course using high-resolution three-dimensional images. By using multidetector-row computed tomography to preoperatively identify a flap's perforators, the surgeon can better plan the flap design to efficiently conduct the flap surgery.
A performance application study of a jet-flap helicopter rotor
NASA Technical Reports Server (NTRS)
Sullivan, R. J.; Laforge, S.; Holchin, B. W.
1972-01-01
A performance study was made of the application of a jet-flap to a reaction-drive rotor for a heavy-lift helicopter mission and for a high-speed-helicopter maneuverability (200 knots, 2g) mission. The results of the study are as follows: As a result of the increase in maximum airfoil lift coefficient achieved by the jet-flap, rotor solidity is reduced with the jet-flap to approximately 59% of a nonjet-flap rotor. As a result of the saving in rotor solidity, and hence in rotor weight, the jet-flap configuration had a 21% higher productivity than a nonjet-flap configuration. Of the three propulsion systems studied utilizing a jet-flap (hot cycle, warm cycle, cold cycle) the hot cycle gave the largest increase in productivity. The 200 knot 2g mission is performed best with a warm cycle propulsion system. The jet-flap permits designing for a rotor blade loading coefficient C sub T/sigma = .170 at 2g without encountering blade stall. The jet-flap rotor permits a 200 knot 2g maneuver without suffering the penalty of an unreasonable rotor solidity that would be required by a nonjet-flap rotor.
Ortega-Usobiaga, J; Llovet-Osuna, F; Katz, T; Djodeyre, M R; Druchkiv, V; Bilbao-Calabuig, R; Baviera, J
2018-02-01
To assess visual outcomes of retreatment after laser in situ keratomileusis (LASIK) by lifting the flap or performing photorefractive keratectomy (PRK) on the flap, as well as to establish whether there was an increased risk of epithelial ingrowth (EIG) when LASIK and lifting of the flap are separated by a long time interval and to determine the incidence of corneal haze after PRK. Retrospective study of 4077 patients (5468 eyes) who underwent LASIK and subsequent retreatment were reviewed in order to study their visual results and identify cases of EIG and corneal haze. Enhancements included 5196 eyes from 3876 patients that were retreated by lifting the flap, and 272 eyes from 201 patients that were retreated by PRK on the flap. No statistically significant differences were found between the retreatments in terms of predictability, efficacy, and safety. A total of 704 cases of EIG were found after lifting the flap, for which surgical cleansing was necessary in 70. Surgical cleansing decreased the efficacy index when compared with patients with EIG who did not need cleansing (P=.01). Differences in terms of safety and predictability were not statistically significant. The incidence of corneal haze after ablation of the surface of the previous flap was 14.34%, although none of these cases were clinically relevant. Visual outcomes were similar between patients who were retreated by lifting the flap and those who underwent PRK. The incidence of EIG when the flap was lifted was 13.55%. The incidence of EIG increases with the time elapsed between the primary procedure and retreatment. Copyright © 2017 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.
The Clinical Application of Anterolateral Thigh Flap
Lee, Yao-Chou; Chiu, Haw-Yen; Shieh, Shyh-Jou
2011-01-01
The anterolateral thigh flap can provide a large skin paddle nourished by a long and large-caliber pedicle and can be harvested by two-team work. Most importantly, the donor-site morbidity is minimal. However, the anatomic variations decreased its popularity. By adapting free-style flap concepts, such as preoperative mapping of the perforators and being familiar with retrograde perforator dissection, this disadvantage had been overcome gradually. Furthermore, several modifications widen its clinical applications: the fascia lata can be included for sling or tendon reconstruction, the bulkiness could be created by including vastus lateralis muscle or deepithelization of skin flap, the pliability could be increased by suprafascial dissection or primary thinning, the pedicle length could be lengthening by proximally eccentric placement of the perforator, and so forth. Combined with these technical and conceptual advancements, the anterolateral thigh flap has become the workhorse flap for soft-tissue reconstructions from head to toe. PMID:22567234
Defining the Role of Free Flaps in Partial Breast Reconstruction.
Smith, Mark L; Molina, Bianca J; Dayan, Erez; Jablonka, Eric M; Okwali, Michelle; Kim, Julie N; Dayan, Joseph H
2018-03-01
Free flaps have a well-established role in breast reconstruction after mastectomy; however, their role in partial breast reconstruction remains poorly defined. We reviewed our experience with partial breast reconstruction to better understand indications for free tissue transfer. A retrospective review was performed of all patients undergoing partial breast reconstruction at our center between February 2009 and October 2015. We evaluated the characteristics of patients who underwent volume displacement procedures versus volume replacement procedures and free versus pedicled flap reconstruction. There were 78 partial breast reconstructions, with 52 reductions/tissue rearrangements (displacement group) and 26 flaps (replacement group). Bra cup size and body mass index (BMI) were significantly smaller in the replacement group. Fifteen pedicled and 11 free flaps were performed. Most pedicled flaps (80.0%) were used for lateral or upper pole defects. Most free flaps (72.7%) were used for medial and inferior defects or when there was inadequate donor tissue for a pedicled flap. Complications included hematoma, cellulitis, and one aborted pedicled flap. Free and pedicled flaps are useful for partial breast reconstruction, particularly in breast cancer patients with small breasts undergoing breast-conserving treatment (BCT). Flap selection depends on defect size, location, and donor tissue availability. Medial defects are difficult to reconstruct using pedicled flaps due to arc of rotation and intervening breast tissue. Free tissue transfer can overcome these obstacles. Confirming negative margins before flap reconstruction ensures harvest of adequate volume and avoids later re-operation. Judicious use of free flaps for oncoplastic reconstruction expands the possibility for breast conservation. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Propeller Perforator Flaps in Distal Lower Leg: Evolution and Clinical Applications
2012-01-01
Simple or complex defects in the lower leg, and especially in its distal third, continue to be a challenging task for reconstructive surgeons. A variety of flaps were used in the attempt to achieve excellence in form and function. After a long evolution of the reconstructive methods, including random pattern flaps, axial pattern flaps, musculocutaneous flaps and fasciocutaneous flaps, the reappraisal of the works of Manchot and Salmon by Taylor and Palmer opened the era of perforator flaps. This era began in 1989, when Koshima and Soeda, and separately Kroll and Rosenfield described the first applications of such flaps. Perforator flaps, whether free or pedicled, gained a high popularity due to their main advantages: decreasing donor-site morbidity and improving aesthetic outcome. The use as local perforator flaps in lower leg was possible due to a better understanding of the cutaneous circulation, leg vascular anatomy, angiosome and perforasome concepts, as well as innovations in flaps design. This review will describe the evolution, anatomy, flap design, and technique of the main distally pedicled propeller perforator flaps used in the reconstruction of defects in the distal third of the lower leg and foot. PMID:22783507
Effect of marking pens on femtosecond laser-assisted flap creation.
Ide, Takeshi; Kymionis, George D; Abbey, Ashkan M; Yoo, Sonia H; Culbertson, William W; O'Brien, Terrence P
2009-06-01
To compare the ease of the flap lift after central corneal marking with 2 types of marking pens after femtosecond laser-assisted flap creation in laser in situ keratomileusis. Bascom Palmer Eye Institute, University of Miami, Miami, Florida, USA. Porcine eyes were prepared for flap creation with a femtosecond laser (IntraLase). The eyes were assigned to 1 of 4 groups. After the femtosecond laser treatment, the difficulty of flap lifting the 4 groups was compared. Twelve porcine eyes, 3 in each group, were evaluated. In the 2 groups in which an oil-based pen was used, the corneal flap could not be lifted. In the 2 groups in which a water-based pen was used, the corneal flap was easily lifted. Oil-based ink may reduce the ability of the femtosecond laser to penetrate the cornea. The resultant corneal flap may require aggressive manipulation to be lifted. When used to mark the center of the cornea before flap creation, water-based ink provided greater ease of corneal flap lifting than oil-based ink. Because the marking is located over the center of the pupil, any alteration of the cornea in this area from aggressive flap lifting may result in substantial visual loss. Therefore, the use of an oil-based ink to mark the central cornea must be avoided to prevent traumatic irregularities of the flap stroma.
Double transverse myocutaneous gracilis free flaps for unilateral breast reconstruction.
Werdin, Frank; Haug, Daniel M; Amr, Amro; Schoeller, Thomas
2016-10-01
In cases were the deep inferior epigastric perforator flap (DIEP flap) is not available and unilateral transverse myocutaneous gracilis flap (TMG flap) is not sufficient for breast reconstruction, we perform double TMG flaps as a reconstructive method. In this report, we present our results of the use of double TMG free-flap-transfer for unilateral breast reconstruction. Between August 2004 and June 2012 we performed 58 TMG flaps in 29 patients for unilateral breast reconstruction. Patient data were analyzed and operative outcome (operation time, complication rate and aesthetic results) were investigated. Aesthetic outcome was evaluated retrospectively via photo documentation by an independent plastic surgeon. The results were classified in;unsatisfactory, satisfactory, good and very good. The average operating time was 6 hours 55 minutes (295 - 650 minutes). Of 58 TMG flaps, 57 (98.3%) were successful. Thrombosis occurred in seven (12%) cases (1 arterial, 6 venous). Flap salvage was successful in six cases and flap failure occurred in one (1.7%) case. The results of 25 patients were graded as good and very good. Three patients showed satisfying and one patient unsatisfying results. Double TMG flaps in unilateral breast reconstruction could lead to good operative results. This method further expands the range of options with autologous tissue in reconstructive breast surgery. © 2015 Wiley Periodicals, Inc. Microsurgery 36:539-545, 2016. © 2015 Wiley Periodicals, Inc.
Flap-edge aeroacoustic measurements and predictions
NASA Astrophysics Data System (ADS)
Brooks, Thomas F.; Humphreys, William M.
2003-03-01
An aeroacoustic model test has been conducted to investigate the mechanisms of sound generation on high-lift wing configurations. This paper presents an analysis of flap side-edge noise, which is often the most dominant source. A model of a main element wing section with a half-span flap was tested at low speeds of up to a Mach number of 0.17, corresponding to a wing chord Reynolds number of approximately 1.7 million. Results are presented for flat (or blunt), flanged, and round flap-edge geometries, with and without boundary-layer tripping, deployed at both moderate and high flap angles. The acoustic database is obtained from a small aperture directional array (SADA) of microphones, which was constructed to electronically steer to different regions of the model and to obtain farfield noise spectra and directivity from these regions. The basic flap-edge aerodynamics is established by static surface pressure data, as well as by computational fluid dynamics (CFD) calculations and simplified edge flow analyses. Distributions of unsteady pressure sensors over the flap allow the noise source regions to be defined and quantified via cross-spectral diagnostics using the SADA output. It is found that shear layer instability and related pressure scatter is the primary noise mechanism. For the flat edge flap, two noise prediction methods based on unsteady-surface-pressure measurements are evaluated and compared to measured noise. One is a new causality spectral approach developed here. The other is a new application of an edge-noise scatter prediction method. The good comparisons for both approaches suggest that the prediction models capture much of the physics. Areas of disagreement appear to reveal when the assumed edge noise mechanism does not fully define the noise production. For the different edge conditions, extensive spectra and directivity are presented. The complexity of the directivity results demonstrate the strong role of edge source geometry and frequency in
Accuracy of Visual Estimation of LASIK Flap Thickness.
Brenner, Jason E; Fadlallah, Ali; Hatch, Kathryn M; Choi, Catherine; Sayegh, Rony R; Kouyoumjian, Paul; Wu, Simon; Frangieh, George T; Melki, Samir A
2017-11-01
To assess the accuracy of surgeons' visual estimation of LASIK flap thickness when created by a femtosecond laser by comparing it to ultrasound measurements. Surgeons were asked to visually estimate the thickness of a femtosecond flap during the procedure. Total corneal thickness was measured by ultrasound pachymetry prior to the procedure and the stromal bed was similarly measured after flap lifting. The estimates from three experienced surgeons (cornea fellowship trained and more than 5 years in practice) were compared to those of three cornea fellows, with each surgeon evaluating 20 eyes (120 total). Surgeons were not told the thickness of the flaps unless required for safety reasons. The average difference between visual and ultrasonic estimation of LASIK flap thickness was 15.20 μm. The flap was 10 μm thicker than estimated in 37% of eyes, 20 μm thicker in 17% of eyes, and 30 μm thicker in 10% of eyes. The largest deviation was 53 μm. There was no statistically significant difference between the accuracy of experienced surgeons and fellows (P = .51). There are significant differences between surgeons' visual estimates and ultrasonic measurements of LASIK flap thickness. Relying on these visual estimates may lead to deeper excimer laser ablation than intended. This could lead to thinner residual stromal beds and higher percent tissue altered than planned. The authors recommend that surgeons measure flaps intraoperatively to maximize accuracy and safety. [J Refract Surg. 2017;33(11):765-767.]. Copyright 2017, SLACK Incorporated.
[The repair of bulky tissue defect of forearm with skin flaps].
Huang, Xiaoyuan; Long, Jianhong; Xie, Tinghong; Zhang, Minghua; Zhang, Pihong; Yang, Xinghua; Zhong, Keqin
2002-12-01
To evaluate the repairing methods of bulky tissue defect of forearm with flaps. Twenty-one burned patients with wounds in the forearm were enrolled in this study. The injury causes were high-voltage electricity, hot press or crush injury. After local debridement, the forearm defects were repaired with pedicled complex flaps, latissimus dorsi musculocutaneous island flaps or large thoraco-abdominal flaps immediately. All the flaps survived very well with satisfactory results except for 1 patient in whom local ischemic necrosis and sub-flap infection at the distal end of the flap occurred. Early debridement followed by skin flaps with pedicles or musculocutaneous flaps transfer could be simple, safe and reliable treatment strategies in the management of bulky tissue defects of the forearm due to burn, electric injury, or other devastating injuries.
The Anterior Interosseus Artery Perforator Flap: Anatomical Dissections and Clinical Study.
Panse, Nikhil S; Joshi, Sheetal B; Sahasrabudhe, Parag B; Bahetee, B; Gurude, Pradnya; Chandanwale, Ajay
2017-05-01
Reconstruction of upper extremity deformities continues to be a challenge to the reconstructive surgeon. Various loco regional, distant and free flaps are available for reconstruction. However, each has its own set of advantages and disadvantages. Of the commonly performed local flaps, radial artery forearm flap, and the posterior interosseus artery flap stand out prominently. Recently, perforator propeller flaps have been used for resurfacing the upper extremity. The anterior interosseus artery perforator flap is an uncommonly used and described flap. This study was divided into anatomical study and clinical application in a IV level of evidence. In the anatomical study, five upper extremities were studied. Clinically, 12 patients underwent reconstruction using the anterior interosseus artery perforator flap. Flaps were performed by a single surgeon. A retrospective review of these cases from November 2008 to May 2014 is presented. The anterior interosseus artery perforator was identified in four out of five cadaver limbs. The septocutaneous perforator was in the fifth extensor compartment around 4 cm proximal to the wrist joint. Of the twelve flaps, there was complete necrosis in one flap, and partial necrosis in one flap. The patient with complete necrosis underwent skin grafting at a later date. The wound healed secondarily in case of partial flap necrosis. Anterior interosseus artery perforator flap must be considered as an important reconstructive option in the armamentarium of the plastic surgeon, while managing hand and wrist defects.
The Anterior Interosseus Artery Perforator Flap: Anatomical Dissections and Clinical Study
Panse, Nikhil S; Joshi, Sheetal B; Sahasrabudhe, Parag B; Bahetee, B; Gurude, Pradnya; Chandanwale, Ajay
2017-01-01
BACKGROUND Reconstruction of upper extremity deformities continues to be a challenge to the reconstructive surgeon. Various loco regional, distant and free flaps are available for reconstruction. However, each has its own set of advantages and disadvantages. Of the commonly performed local flaps, radial artery forearm flap, and the posterior interosseus artery flap stand out prominently. Recently, perforator propeller flaps have been used for resurfacing the upper extremity. The anterior interosseus artery perforator flap is an uncommonly used and described flap. METHODS This study was divided into anatomical study and clinical application in a IV level of evidence. In the anatomical study, five upper extremities were studied. Clinically, 12 patients underwent reconstruction using the anterior interosseus artery perforator flap. Flaps were performed by a single surgeon. A retrospective review of these cases from November 2008 to May 2014 is presented. RESULTS The anterior interosseus artery perforator was identified in four out of five cadaver limbs. The septocutaneous perforator was in the fifth extensor compartment around 4 cm proximal to the wrist joint. Of the twelve flaps, there was complete necrosis in one flap, and partial necrosis in one flap. The patient with complete necrosis underwent skin grafting at a later date. The wound healed secondarily in case of partial flap necrosis. CONCLUSION Anterior interosseus artery perforator flap must be considered as an important reconstructive option in the armamentarium of the plastic surgeon, while managing hand and wrist defects. PMID:28713704
Folding in and out: passive morphing in flapping wings.
Stowers, Amanda K; Lentink, David
2015-03-25
We present a new mechanism for passive wing morphing of flapping wings inspired by bat and bird wing morphology. The mechanism consists of an unactuated hand wing connected to the arm wing with a wrist joint. Flapping motion generates centrifugal accelerations in the hand wing, forcing it to unfold passively. Using a robotic model in hover, we made kinematic measurements of unfolding kinematics as functions of the non-dimensional wingspan fold ratio (2-2.5) and flapping frequency (5-17 Hz) using stereo high-speed cameras. We find that the wings unfold passively within one to two flaps and remain unfolded with only small amplitude oscillations. To better understand the passive dynamics, we constructed a computer model of the unfolding process based on rigid body dynamics, contact models, and aerodynamic correlations. This model predicts the measured passive unfolding within about one flap and shows that unfolding is driven by centrifugal acceleration induced by flapping. The simulations also predict that relative unfolding time only weakly depends on flapping frequency and can be reduced to less than half a wingbeat by increasing flapping amplitude. Subsequent dimensional analysis shows that the time required to unfold passively is of the same order of magnitude as the flapping period. This suggests that centrifugal acceleration can drive passive unfolding within approximately one wingbeat in small and large wings. Finally, we show experimentally that passive unfolding wings can withstand impact with a branch, by first folding and then unfolding passively. This mechanism enables flapping robots to squeeze through clutter without sophisticated control. Passive unfolding also provides a new avenue in morphing wing design that makes future flapping morphing wings possibly more energy efficient and light-weight. Simultaneously these results point to possible inertia driven, and therefore metabolically efficient, control strategies in bats and birds to morph or recover
The perforator pedicled propeller (PPP) flap method: report of two cases.
Hyakusoku, Hiko; Ogawa, Rei; Oki, Koichiro; Ishii, Nobuaki
2007-10-01
Perforator flaps are thin free-tissue transfers consisting of skin and subcutaneous tissue which have the advantage of decreasing donor site morbidity. We have reconstructed postburn scar contractures using "propeller flaps" of the remaining healthy skin around the recipient sites. In this paper, we report on two cases and describe the concept of using "perforator flaps" and "propeller flaps" together as what are called "perforator pedicled propeller (PPP) flaps." Patient 1 was an 18-year-old man with a sacral pressure ulcer. The soft tissue defect was reconstructed with a rotated superior gluteal artery PPP flap. Patient 2 was a 53-year-old woman who presented with an open fracture of the right elbow. The skin defect over the fracture was covered with a rotated deep brachial artery PPP flap raised on the lateral upper arm. The PPP flaps are useful for burn reconstruction and repairing various types of wound. Moreover, microsurgery is unnecessary. The PPP flap may be classified into two types: the central axis type and the acentric axis type. The central axis PPP flap is significant when used as a 90-degree-rotation island flap, and the acentric axis PPP flap is significant when used as a 180-degree-rotation island flap. Both types are easy to harvest and useful for repairing various kinds of wound.
Sahin, Cihan; Aysal, Bilge Kagan; Ergun, Ozge
2016-08-01
Ergun et al previously demonstrated the efficacy of hydrostatic dilation in a TRAM flap model in an experimental study. We investigated the effect of hydrostatic dilation on a fasciocutaneous flap model. Eighteen female Wistar rats were equally divided into 3 groups, of which 1 served as a control. In the second, the abdominal fasciocutaneous flap surgical delay procedure was performed by division of the left superficial inferior epigastric (SIE) vessels. In the third, hydrostatic dilation was performed on the left SIE artery and vein, with a mean pressure of 300 mm Hg, while elevating the flap on the right-sided SIE pedicle. The groups were compared by microangiography and by the survival ratio of abdominal flaps 7 days after elevation. The mean (SD) flap necrosis rates were as follows: control group, 44.75% (4.31%); delay group, 33.32% (7.11%); and hydrostatic dilation group, 32.51% (5.03%). There was a significant difference between the control group and the other 2 groups (P < 0.05). There was no difference between the delay and hydrostatic dilation groups with respect to surface area necrosis. The microangiographies showed remarkable increased vascularity in the delay and hydrostatic dilation groups. Hydrostatic dilation is a new method of enhancing flap viability that could be used in clinical cases in place of surgical delay once further studies and clinical trials are completed.
Boomerang flap reconstruction for the breast.
Baumholtz, Michael A; Al-Shunnar, Buthainah M; Dabb, Richard W
2002-07-01
The boomerang-shaped latissimus dorsi musculocutaneous flap for breast reconstruction offers a stable platform for breast reconstruction. It allows for maximal aesthetic results with minimal complications. The authors describe a skin paddle to obtain a larger volume than either the traditional elliptical skin paddle or the extended latissimus flap. There are three specific advantages to the boomerang design: large volume, conical shape (often lacking in the traditional skin paddle), and an acceptable donor scar. Thirty-eight flaps were performed. No reconstruction interfered with patient's ongoing oncological regimen. The most common complication was seroma, which is consistent with other latissimus reconstructions.
Neodymium:yttrium-aluminum-garnet laser fusion of endarterectomy flaps.
Humphrey, P W; Slocum, M M; Loy, T S; Silver, D
1995-07-01
This study evaluated the efficacy of neodymium:yttrium-aluminum-garnet laser welding of flaps in canine arteries and in securing the distal flap during human carotid endarterectomy. Endarterectomy flaps were created in both common carotid and both common femoral arteries in 12 dogs. The flaps were repaired with either the neodymium:yttrium-aluminum-garnet laser or with 6-0 polypropylene sutures. The arteries were removed after duplex scanning at either 7 or 28 days. Eighteen high carotid endarterectomy flaps in 16 patients have been subsequently secured with the laser welding technique. Laser repairs (125 +/- 19 joule) of the canine arteries were completed more quickly than suture repairs (mean 25 seconds vs 135 seconds, respectively; p < 0.04). Duplex ultrasonography revealed no discernable differences between the two groups of arteries. Arteries studied at 7 days revealed three microscopic flaps (two suture, one laser), more subintimal fibroblastic proliferation in suture than laser-repaired carotid arteries (3: 1, p = 0.0530), and similar amounts of inflammation in suture- and laser-repaired arteries. Arteries studied at 28 days revealed one microscopic intimal flap (suture-repaired); equal fibroblastic and inflammatory responses in suture- and laser-repaired vessels; and no evidence of laser thermal injury. Eighteen carotid endarterectomy flaps have been successfully fused with no immediate or long-term complications in 16 patients (follow-up of 0 to 24 months). Laser fusion appears to be a safe and effective method for securing distal carotid endarterectomy flaps.
Leatherbarrow, Brian; Watson, Adam; Wilcsek, Geoffrey
2006-01-01
To describe the use and outcomes of a versatile surgical technique in the reconstruction of deep soft tissue and bony defects of the medial canthus. A retrospective review of consecutive cases requiring reconstruction of medial canthal defects involving loss of periosteum or bone by a median forehead pericranial flap and full-thickness skin grafting in a tertiary referral hospital setting. Two techniques were used: an open technique, using a midline forehead incision; and an endoscopic technique, using 2 incisions behind the hairline. Twenty-one cases were identified: 19 open and 2 endoscopic. The average length of follow-up was 13 months (range, 6-50 months). Ten cases required additional oculoplastic procedures including local periosteal flaps and mucous membrane grafts. Two cases (10%) had complete flap failure; one of these was caused by infection. Five (24%) had partial (< 50%) skin graft necrosis. Two cases (10%) have required further surgery. Our experience shows the pericranial flap to be versatile, robust, and easy to manipulate, offering advantages over alternative techniques when used for the repair of deep medial canthal defects. It is a valuable reconstructive technique that can yield good cosmetic and functional results.
Hai, Heng-lin; Shen, Chuan-an; Chai, Jia-ke; Li, Hua-tao
2012-02-01
To explore the clinical effect of transplantation of the long head of biceps femoris muscle flap in combination with semi-V posterior thigh fasciocutaneous flap for repair of pressure sores over ischial tuberosity. Eight patients with 10 deep pressure sores over ischial tuberosity were admitted to the First Affiliated Hospital to the PLA General Hospital and the 98th Hospital of PLA from April 2004 to June 2010. The wounds measured from 2 cm × 2 cm to 6 cm × 4 cm were covered with the long head of biceps femoris muscle flap and semi-V posterior thigh fasciocutaneous flap (ranged from 10 cm × 6 cm to 13 cm × 8 cm). The condition of flaps was observed and followed up for a long time. All flaps survived. Nine wounds healed by first intention. Subcutaneous accumulation of fluids occurred in one wound with formation of a sinus at drainage site, and it healed after dressing change for 25 days. Patients were followed up for 7 to 34 months. Sore recurred in one patient 9 months after surgery, and it was successfully repaired with the same flap for the second time. Flaps in the other 7 patients appeared satisfactory with soft texture and without ulceration. This combined flap is easy in formation and transfer, and it causes little side injury with good resistance against pressure. It is a new method for repair of pressure sore over sacral region.
[Predictability of the corneal flap creation with the femtosecond laser in LASIK].
Mai, Zhi-bin; Liu, Su-bing; Nie, Xiao-li; Sun, Hong-xia; Xin, Bao-li; Tang, Xiu-xia
2012-05-01
To observe the predictability of corneal flap creation with the FEMTO LDV femtosecond laser and analyze preliminarily the factors correlating to the thickness and diameter of the flap . It was a study of serial cases. 260 eyes of 130 consecutive patients were treated with the FEMTO LDV. The eyes were assigned to two groups according to intended flap thickness, 110 µm (208 eyes) and 90 µm (52 eyes). Intended flap diameter varied from 8.5 to 9.5 mm. Difference analysis of flap diameter and intended diameter as well as flap thickness and intended thickness were made. The data was analyzed with SPSS to sum up a multiple stepwise regression formula that could express their quantitative relationship. The 90 µm flap group had a average flap thickness of (95.12 ± 7.65) µm, while for the 110 µm group the average flap thickness was (104.81 ± 3.09) µm. The difference between right and left eyes was not statistically significant (t(110 µm) = -1.223, t(90 µm) = -1.343, P > 0.05). Corneal flap thickness was inversely correlated with flap diameter (r(110 µm) = -0.143, r(90 µm) = -0.315, P < 0.05), but was not related to preoperative patient age, corneal thickness, keratometric value K or intraocular pressure (r(110 µm) = -0.160, 0.054, -0.011, -0.363; r(90 µm) = 0.024, 0.074, -0.212, -0.434, all P > 0.05). Corneal flap diameter was positively correlated with preoperative corneal keratometric value K and thickness (P < 0.001, P < 0.05). Multiple stepwise regression analysis showed flap diameter was an influencing factor for flap thickness. Preoperative corneal keratometric value K and thickness were influencing factors for flap diameter. The LASIK flap creation with the FEMTO LDV laser has relatively good predictability. Flap diameter is an influencing factor for flap thickness.
Principles of definitive soft tissue coverage with flaps.
Levin, L Scott
2008-01-01
Despite the emergence of negative pressure wound therapy with reticulated open cell foam (NPWT/ROCF) as delivered by V.A.C.(R) Therapy (KCI, San Antonio, TX) for orthopaedic trauma, vascularized tissue transfer whether it be pedicle, free, or tissue transfer using the operating microscope or as an island, remains the mainstay of soft tissue reconstruction for orthopaedic traumatology. The critisism of microvascular procedures has been that they are lengthy, costly, and required technical expertise to perform. While technical skills are required, microsurgical care has evolved into a routine operation with high degrees of success in experienced hand. The problem that still remains is access to surgeons who are interested in soft tissue reconstruction and can perform definitive coverage with flaps. There is a need in the orthopaedic community to solve the problem of lack of flap surgeons and as a result, NPWT/ROCF has been touted as the answer to flap reconstruction. NPWT/ROCF is an important addition to soft tissue reconstruction but it serves as a bridge rather than definitive coverage in many hands. Just as wound technology is evolving with tissue substitutes, growth factors and NPWT/ROCF flaps technology continues to advance with new perforator flaps and local regional flaps, particularly the sural flap, coming on line as mainstays of soft tissue reconstruction.
Droplet ejection and sliding on a flapping film
NASA Astrophysics Data System (ADS)
Chen, Xi; Doughramaji, Nicole; Betz, Amy Rachel; Derby, Melanie M.
2017-03-01
Water recovery and subsequent reuse are required for human consumption as well as industrial, and agriculture applications. Moist air streams, such as cooling tower plumes and fog, represent opportunities for water harvesting. In this work, we investigate a flapping mechanism to increase droplet shedding on thin, hydrophobic films for two vibrational cases (e.g., ± 9 mm and 11 Hz; ± 2 mm and 100 Hz). Two main mechanisms removed water droplets from the flapping film: vibrational-induced coalescence/sliding and droplet ejection from the surface. Vibrations mobilized droplets on the flapping film, increasing the probability of coalescence with neighboring droplets leading to faster droplet growth. Droplet departure sizes of 1-2 mm were observed for flapping films, compared to 3-4 mm on stationary films, which solely relied on gravity for droplet removal. Additionally, flapping films exhibited lower percentage area coverage by water after a few seconds. The second removal mechanism, droplet ejection was analyzed with respect to surface wave formation and inertia. Smaller droplets (e.g., 1-mm diameter) were ejected at a higher frequency which is associated with a higher acceleration. Kinetic energy of the water was the largest contributor to energy required to flap the film, and low energy inputs (i.e., 3.3 W/m2) were possible. Additionally, self-flapping films could enable novel water collection and condensation with minimal energy input.
"Reading man flap" design for reconstruction of circular infraorbital and malar skin defects.
Seyhan, Tamer; Caglar, Baris
2008-11-01
Surgical complications such as lid retraction and ectropion from graft or flap scar contracture make reconstruction of skin defects in the malar and infraorbital regions challenging. A new flap design, the reading man flap, was used to overcome these problems. The Limberg and bilobed flap were compared with the reading man flap. The reading man flap consists mainly of a superiorly based quadrangular flap and an inferiorly based triangular flap. Malar and infraorbital circular skin defects measuring 14 x 14 to 40 x 40 mm were reconstructed with a reading man flap in 13 patients. The defects occurred after basal cell carcinoma in all patients. The Limberg flap, bilobed flap, and reading man flap were planned for same-sized defects on the abdominoplasty resection material. The results were compared in terms of total scar area, scar length, and total healthy skin area discarded. When comparing the 3 flap designs, the reading man flap was the most suitable flap in terms of total scar area and length. The reading man flap can be used to reconstruct malar and infraorbital circular defects with good cosmetic results and without creating any tractional forces to the eyelids.
Noise Radiation from a Continuous Mold-Line Link Flap Configuration
NASA Technical Reports Server (NTRS)
Hutcheson, Florence V.; Brooks, Thomas F.; Humphreys, William M., Jr.
2011-01-01
The results of an experimental study of the noise from a Continuous Mold-Line Link (CML) flap are presented. Acoustic and unsteady surface pressure measurements were performed on a main element wing section with a half-span CML flap in NASA Langley s Quiet Flow Facility. The acoustic data were acquired with a medium aperture directional array (MADA) of microphones. The Deconvolution Approach for the Mapping of Acoustic Sources (DAMAS) method is applied to determine the spatial distribution and strength of the noise sources over the surface of the test model. A Coherent Output Power (COP) method which relates the output from unsteady surface pressure sensors to the output of the MADA is also used to obtain more detailed characteristics of the noise source distribution in the trailing edge region of the CML. These results are compared to those obtained for a blunt flap to quantify the level of noise benefit that is achieved with the CML flap. The results indicate that the noise from the CML region of the flap is 5 to 17 dB lower (depending on flap deflection and Mach number) than the noise from the side edge region of the blunt flap. Lower noise levels are obtained for all frequencies. Spectral analysis of the noise from the cove region of the CML and blunt flap models also reveal a spectral peak in the high frequency range that is related to noise scattering at the trailing edge of the main element. The peaks in the CML and blunt flap cove noise spectra are close in level and often exceed blunt side edge noise. Applying a strip of serrated tape to the trailing edge of the CML flap model main airfoil reduced the peak but increased other noise somewhat. Directivity measurements show that the CML flap can be more directional than the blunt flap.
Noise Radiation from a Continuous Mold-Line Link Flap Configuration
NASA Technical Reports Server (NTRS)
Hutcheson, Florence V.; Brooks, Thomas F.; Humphreys, William M.
2008-01-01
The results of an experimental study of the noise from a Continuous Mold-Line Link (CML) flap are presented. Acoustic and unsteady surface pressure measurements were performed on a main element wing section with a half-span CML flap in NASA Langley s Quiet Flow Facility. The acoustic data were acquired with a medium aperture directional array (MADA) of microphones. The Deconvolution Approach for the Mapping of Acoustic Sources (DAMAS) method is applied to determine the spatial distribution and strength of the noise sources over the surface of the test model. A Coherent Output Power (COP) method which relates the output from unsteady surface pressure sensors to the output of the MADA is also used to obtain more detailed characteristics of the noise source distribution in the trailing edge region of the CML. These results are compared to those obtained for a blunt flap to quantify the level of noise benefit that is achieved with the CML flap. The results indicate that the noise from the CML region of the flap is 5 to 17 dB lower (depending on flap deflection and Mach number) than the noise from the side edge region of the blunt flap. Lower noise levels are obtained for all frequencies. Spectral analysis of the noise from the cove region of the CML and blunt flap models also reveal a spectral peak in the high frequency range that is related to noise scattering at the trailing edge of the main element. The peaks in the CML and blunt flap cove noise spectra are close in level and often exceed blunt side edge noise. Applying a strip of serrated tape to the trailing edge of the CML flap model main airfoil, reduced the peak but increased other noise somewhat. Directivity measurements show that the CML flap can be more directional than the blunt flap.
Traumatic corneal flap displacement after laser in situ keratomileusis (LASIK)
Tsai, Tsung-Han; Peng, Kai-Ling; Lin, Chien-Jen
2017-01-01
Background Laser in situ keratomileusis (LASIK) is the most common and popular procedure performed for the correction of refractive errors in the last two decades. We report a case of traumatic flap displacement with flap folding which occurred 3 years after LASIK was performed. Previous literature suggests that vision prognosis would be closely related to proper and prompt management of traumatic flap displacement with flap folding 3 years after LASIK. Case presentation A 23-year-old female presented to our hospital who had undergone uneventful LASIK in both eyes 3 years prior. Unfortunately, she had suffered a blunt trauma in her right eye in a car accident. A late onset of corneal flap displacement was found with upper and lower portion of the flap being folded inside the corneal bed. Surgical intervention for debridement with subsequent reposition of corneal flap was performed as soon as possible in the operating room. A bandage contact lens was placed, and topical antibiotic and corticosteroids were given postoperatively. Two days after the operation, the displaced corneal flap was found to be well attached smoothly on the corneal bed without folds. The best-corrected visual acuity was 6/6 with refraction of −0.75 D to 1.0 D ×175° in her right eye 1 month later. Literature review We reviewed a total of 19 published cases of late-onset traumatic flap dislocations or displacements after LASIK with complete data from 2000 to 2014. Conclusion Traumatic displacement of corneal flaps after LASIK may occur after blunt injury with specific direction of force to the flap margin, especially tangential one. According to the previous literature, late-onset traumatic flap displacement may happen at any time after LASIK and be caused by various types of injuries. Fortunately, good visual function could mostly be restored with immediate and proper management. PMID:28458585
Traumatic corneal flap displacement after laser in situ keratomileusis (LASIK).
Tsai, Tsung-Han; Peng, Kai-Ling; Lin, Chien-Jen
2017-01-01
Laser in situ keratomileusis (LASIK) is the most common and popular procedure performed for the correction of refractive errors in the last two decades. We report a case of traumatic flap displacement with flap folding which occurred 3 years after LASIK was performed. Previous literature suggests that vision prognosis would be closely related to proper and prompt management of traumatic flap displacement with flap folding 3 years after LASIK. A 23-year-old female presented to our hospital who had undergone uneventful LASIK in both eyes 3 years prior. Unfortunately, she had suffered a blunt trauma in her right eye in a car accident. A late onset of corneal flap displacement was found with upper and lower portion of the flap being folded inside the corneal bed. Surgical intervention for debridement with subsequent reposition of corneal flap was performed as soon as possible in the operating room. A bandage contact lens was placed, and topical antibiotic and corticosteroids were given postoperatively. Two days after the operation, the displaced corneal flap was found to be well attached smoothly on the corneal bed without folds. The best-corrected visual acuity was 6/6 with refraction of -0.75 D to 1.0 D ×175° in her right eye 1 month later. We reviewed a total of 19 published cases of late-onset traumatic flap dislocations or displacements after LASIK with complete data from 2000 to 2014. Traumatic displacement of corneal flaps after LASIK may occur after blunt injury with specific direction of force to the flap margin, especially tangential one. According to the previous literature, late-onset traumatic flap displacement may happen at any time after LASIK and be caused by various types of injuries. Fortunately, good visual function could mostly be restored with immediate and proper management.
Aerodynamic effects of flexibility in flapping wings.
Zhao, Liang; Huang, Qingfeng; Deng, Xinyan; Sane, Sanjay P
2010-03-06
Recent work on the aerodynamics of flapping flight reveals fundamental differences in the mechanisms of aerodynamic force generation between fixed and flapping wings. When fixed wings translate at high angles of attack, they periodically generate and shed leading and trailing edge vortices as reflected in their fluctuating aerodynamic force traces and associated flow visualization. In contrast, wings flapping at high angles of attack generate stable leading edge vorticity, which persists throughout the duration of the stroke and enhances mean aerodynamic forces. Here, we show that aerodynamic forces can be controlled by altering the trailing edge flexibility of a flapping wing. We used a dynamically scaled mechanical model of flapping flight (Re approximately 2000) to measure the aerodynamic forces on flapping wings of variable flexural stiffness (EI). For low to medium angles of attack, as flexibility of the wing increases, its ability to generate aerodynamic forces decreases monotonically but its lift-to-drag ratios remain approximately constant. The instantaneous force traces reveal no major differences in the underlying modes of force generation for flexible and rigid wings, but the magnitude of force, the angle of net force vector and centre of pressure all vary systematically with wing flexibility. Even a rudimentary framework of wing veins is sufficient to restore the ability of flexible wings to generate forces at near-rigid values. Thus, the magnitude of force generation can be controlled by modulating the trailing edge flexibility and thereby controlling the magnitude of the leading edge vorticity. To characterize this, we have generated a detailed database of aerodynamic forces as a function of several variables including material properties, kinematics, aerodynamic forces and centre of pressure, which can also be used to help validate computational models of aeroelastic flapping wings. These experiments will also be useful for wing design for small
Aerodynamic effects of flexibility in flapping wings
Zhao, Liang; Huang, Qingfeng; Deng, Xinyan; Sane, Sanjay P.
2010-01-01
Recent work on the aerodynamics of flapping flight reveals fundamental differences in the mechanisms of aerodynamic force generation between fixed and flapping wings. When fixed wings translate at high angles of attack, they periodically generate and shed leading and trailing edge vortices as reflected in their fluctuating aerodynamic force traces and associated flow visualization. In contrast, wings flapping at high angles of attack generate stable leading edge vorticity, which persists throughout the duration of the stroke and enhances mean aerodynamic forces. Here, we show that aerodynamic forces can be controlled by altering the trailing edge flexibility of a flapping wing. We used a dynamically scaled mechanical model of flapping flight (Re ≈ 2000) to measure the aerodynamic forces on flapping wings of variable flexural stiffness (EI). For low to medium angles of attack, as flexibility of the wing increases, its ability to generate aerodynamic forces decreases monotonically but its lift-to-drag ratios remain approximately constant. The instantaneous force traces reveal no major differences in the underlying modes of force generation for flexible and rigid wings, but the magnitude of force, the angle of net force vector and centre of pressure all vary systematically with wing flexibility. Even a rudimentary framework of wing veins is sufficient to restore the ability of flexible wings to generate forces at near-rigid values. Thus, the magnitude of force generation can be controlled by modulating the trailing edge flexibility and thereby controlling the magnitude of the leading edge vorticity. To characterize this, we have generated a detailed database of aerodynamic forces as a function of several variables including material properties, kinematics, aerodynamic forces and centre of pressure, which can also be used to help validate computational models of aeroelastic flapping wings. These experiments will also be useful for wing design for small robotic
The Economy in Autologous Tissue Transfer: Part 1. The Kiss Flap Technique.
Zhang, Yi Xin; Hayakawa, Thomas J; Levin, L Scott; Hallock, Geoffrey G; Lazzeri, Davide
2016-03-01
All reconstructive microsurgeons realize the need to improve aesthetic and functional donor-site outcomes. A "kiss" flap design concept was developed to increase the surface area of skin flap coverage while minimizing donor-site morbidity. The main goal of the kiss flap technique is to harvest multiple skin paddles that are smaller than those raised with traditional techniques, to minimize donor-site morbidity. These smaller flap components are then sutured to each other, or said to kiss each other side-by-side, to create a large, wide flap. The skin paddles in the kiss technique can be linked to one another by a variety of native intrinsic vascular connections, by additional microanastomosis, or both. This technique can be widely applied to both free and pedicle flaps, and essentially allows for the reconstruction of a large defect while providing the easy primary closure of a smaller donor-site defect. According to their origin of blood supply, kiss flaps are classified into three styles and five types. All of the different types of kiss flaps are unique in both flap design and harvest technique. Most kiss flaps are based on common flaps already familiar to the reconstructive surgeon. The basis of the kiss flap design concept is to convert multiple narrow flaps into a single unified flap of the desired greater width. This maximizes the size of the resulting flap and minimizes donor-site morbidity, as a direct linear closure is usually possible. Therapeutic, V.
Free 'mini' groin flap for digital resurfacing.
Tare, M; Ramakrishnan, V
2009-06-01
Ten cases of post-traumatic skin and soft tissue loss over the digits were resurfaced by free 'mini' groin flap. Five patients had defects of the dorsum of the digit, three had proximal palmar defects, one patient had circumferential skin loss and one had multiple digital injuries. The flap was harvested from the contralateral groin using a two-team approach. The average size of the flap was 5.5 x 4.75 cm and the mean operating time was 2.45 hrs. All patients had physiotherapy within 48-72 hrs. There were no flap losses. Six patients were happy with the cosmetic result and did not require any further debulking. We recommend free tissue transfer for digital resurfacing specifically in moderate to large dorsal defects, proximal volar defects, circumferential skin loss and multiple digit injuries.
Angiographic delay: a viable alternative to surgical delay.
Aboutanos, Sharline Z; Spinos, Efstathios; Blanchet, Nadia P
2012-06-01
Selective embolization of the inferior epigastric arteries can serve as a method for transverse rectus abdominis musculocutaneous (TRAM) flap delay. The purpose of this study was to determine whether delay by selective arterial embolization is comparable to traditionally surgically delayed TRAM flaps as reported in the literature, in terms of skin and fat necrosis, and to examine whether certain risk factors play a role in TRAM flap fat necrosis despite angiographic delay. Retrospective chart review was performed for 88 consecutive patients who underwent unilateral TRAM flap breast reconstruction after selective embolization of bilateral inferior epigastric arteries. Between 1997 and 2009, 88 pedicled TRAM flaps were performed for breast reconstruction in women with a mean age of 49.7 years. No patients had flap skin necrosis or total flap loss. In all, 13.6% patients had TRAM flap fat necrosis. Two patients in the TRAM fat necrosis group (16.7%) had a positive history of smoking, which was a statistically significant risk factor for necrosis (P = 0.048). Outcomes of pedicled TRAM flaps delayed by selective arterial embolization are comparable to historical controls of those delayed by traditional surgical means (ligation of artery and vein) and better than nondelayed flaps. Smoking remains a significant risk factor for TRAM flap fat necrosis despite the benefit of delay.
The Gradual Expansion Muscle Flap
2014-01-01
acute shortening and angulation of the tibia and rotational muscle flap coverage and split thickness skin grafting of the soft tissue defect...is also amenable to split-thickness skin grafting after tissue incorporation.11 In addition to donor site morbidity, free tissue transfer is dependent...necessary soft tissue coverage. In the second stage, after the flap has adequately set and overlying skin graft has full adherence, a Taylor Spatial
A novel animal model for skin flap prelamination with biomaterials
NASA Astrophysics Data System (ADS)
Zhou, Xianyu; Luo, Xusong; Liu, Fei; Gu, Chuan; Wang, Xi; Yang, Qun; Qian, Yunliang; Yang, Jun
2016-09-01
Several animal models of skin flap construction were reported using biomaterials in a way similar to prefabrication. However, there are few animal model using biomaterials similar to prelamination, another main way of clinical skin flap construction that has been proved to be reliable. Can biomaterials be added in skin flap prelamination to reduce the use of autogenous tissues? Beside individual clinical attempts, animal model is needed for randomized controlled trial to objectively evaluate the feasibility and further investigation. Combining human Acellular Dermal Matrix (hADM) and autologous skin graft, we prelaminated flaps based on inguinal fascia. One, two, three and four weeks later, hADM exhibited a sound revascularization and host cell infiltration. Prelaminated skin flaps were then raised and microsurgically transplanted back to groin region. Except for flaps after one week of prelamination, flaps from other subgroups successfully reconstructed defects. After six to sixteen weeks of transplantation, hADM was proved to being able to maintain its original structure, having a wealth of host tissue cells and achieving full revascularization.To our knowledge, this is the first animal model of prelaminating skin flap with biomaterials. Success of this animal model indicates that novel flap prelamination with biomaterials is feasible.
Blevitt, Jonathan M; Hack, Michael D; Herman, Krystal; Chang, Leon; Keith, John M; Mirzadegan, Tara; Rao, Navin L; Lebsack, Alec D; Milla, Marcos E
2016-06-10
5-Lipoxygenase activating protein (FLAP) plays a critical role in the metabolism of arachidonic acid to leukotriene A4, the precursor to the potent pro-inflammatory mediators leukotriene B4 and leukotriene C4 Studies with small molecule inhibitors of FLAP have led to the discovery of a drug binding pocket on the protein surface, and several pharmaceutical companies have developed compounds and performed clinical trials. Crystallographic studies and mutational analyses have contributed to a general understanding of compound binding modes. During our own efforts, we identified two unique chemical series. One series demonstrated strong inhibition of human FLAP but differential pharmacology across species and was completely inactive in assays with mouse or rat FLAP. The other series was active across rodent FLAP, as well as human and dog FLAP. Comparison of rodent and human FLAP amino acid sequences together with an analysis of a published crystal structure led to the identification of amino acid residue 24 in the floor of the putative binding pocket as a likely candidate for the observed speciation. On that basis, we tested compounds for binding to human G24A and mouse A24G FLAP mutant variants and compared the data to that generated for wild type human and mouse FLAP. These studies confirmed that a single amino acid mutation was sufficient to reverse the speciation observed in wild type FLAP. In addition, a PK/PD method was established in canines to enable preclinical profiling of mouse-inactive compounds. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.
Nguyen, Cu Dinh; Hult, Jenny; Sheikh, Rafi; Tenland, Kajsa; Dahlstrand, Ulf; Lindstedt, Sandra; Malmsjö, Malin
2017-10-11
It is well known that blood perfusion is important for the survival of skin flaps. As no study has been conducted to investigate how the blood perfusion in human eyelid skin flaps is affected by the flap length and diathermy, the present study was carried out to investigate these in patients. Fifteen upper eyelids were dissected as part of a blepharoplastic procedure, releasing a 30-mm long piece of skin, while allowing the 5 mm wide distal part of the skin to remain attached, to mimic a skin flap (hereafter called a "skin flap"). Blood perfusion was measured before and after repeated diathermy, using laser speckle contrast imaging. Blood perfusion decreased from the base to the tip of the flap: 5 mm from the base, the perfusion was 69%, at 10 mm it was 40%, at 15 mm it was 20%, and at 20 mm it was only 13% of baseline values. Diathermy further decreased blood perfusion (measured 15 mm from the base) to 13% after applying diathermy for the first time, to 6% after the second and to 4% after the third applications of diathermy. Blood perfusion falls rapidly with distance from the base of skin flaps on the human eyelid, and diathermy reduces blood perfusion even further. Clinically, it may be advised that flaps with a width of 5 mm be no longer than 15 mm (i.e., a width:length ratio of 1:3), and that the use of diathermy should be carefully considered.
Liang, Weiqiang; Ji, Chenyang; Chen, Yuhong; Zhang, Ganling; Zhang, Jiaqi; Yao, Yuanyuan; Zhang, Jinming
2016-08-01
To evaluate the effects, particularly the incidence of anastomotic fistula, of a pedicled dartos flap around the urethral orifice in the treatment of urethroplasty of mid-shaft hypospadias. A total of 46 cases of congenital mid-shaft hypospadias were included in this study. The patients ranged in age from 0.7 to 25.4 years and the average was 5.8 years. The patients received penis chordee correction. A transverse preputial island flap was developed for urethral reconstruction. The proximal dartos of the urethral orifice was used to develop a pedicled dartos flap, which was transposed to cover and strengthen neourethral anastomosis. The ventral penile skin defect was repaired by another flap. The 46 patients were examined during follow-up visits for 6 months to 3 years. An anastomotic fistula was observed in one case (2.2 %). Scar healing without fistula was observed in another patient due to poor blood supply to part of the ventral penile skin. No other incidences of fistula, urethral rupture, flap necrosis, wound infections, urinary tract (meatal) stenosis, or urethral diverticulum were observed in the patients. A pedicled dartos flap around the urethral orifice can take advantage of well-vascularized local tissue to add a protective layer to the proximal aspect of the neourethral anastomosis for reducing the incidence of anastomotic fistula in mid-shaft hypospadias repair using a transverse preputial island flap. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
"Apron" flap and re-creation of the inframammary fold following TRAM flap breast reconstruction.
Amir, A; Silfen, R; Hauben, D J
2000-03-01
To the best of our knowledge, the recreation of an inframammary fold after TRAM flap breast reconstruction has not yet been described. This article offers a technique for the creation of an inframammary fold as a secondary procedure. The technique has been performed thus far in two patients with good aesthetic outcomes and no postoperative complications. It may also be suitable for adding bulk to the TRAM flap, especially in bilateral breast reconstruction, and for other minor chest deformities.
Long-Term Patency of Twisted Vascular Pedicles in Perforator-Based Propeller Flaps.
Jakubietz, Rafael G; Nickel, Aljoscha; Neshkova, Iva; Schmidt, Karsten; Gilbert, Fabian; Meffert, Rainer H; Jakubietz, Michael G
2017-10-01
Propeller flaps require torsion of the vascular pedicle of up to 180 degrees. Contrary to free flaps, where the relevance of an intact vascular pedicle has been documented, little is known regarding twisted pedicles of propeller flaps. As secondary surgeries requiring undermining of the flap are common in the extremities, knowledge regarding the necessity to protect the pedicle is relevant. The aim of this study was a long-term evaluation of the patency of vascular pedicle of propeller flaps. In a retrospective clinical study, 22 patients who underwent soft-tissue reconstruction with a propeller flap were evaluated after 43 months. A Doppler probe was used to locate and evaluate the patency of the vascular pedicle of the flap. The flaps were used in the lower extremity in 19 cases, on the trunk in 3 cases. All flaps had healed. In all patients, an intact vascular pedicle could be found. Flap size, source vessel, or infection could therefore not be linked to an increased risk of pedicle loss. The vascular pedicle of propeller flaps remains patent in the long term. This allows reelevation and undermining of the flap. We therefore recommend protecting the pedicle in all secondary cases to prevent later flap loss.
A standardized model for predicting flap failure using indocyanine green dye
NASA Astrophysics Data System (ADS)
Zimmermann, Terence M.; Moore, Lindsay S.; Warram, Jason M.; Greene, Benjamin J.; Nakhmani, Arie; Korb, Melissa L.; Rosenthal, Eben L.
2016-03-01
Techniques that provide a non-invasive method for evaluation of intraoperative skin flap perfusion are currently available but underutilized. We hypothesize that intraoperative vascular imaging can be used to reliably assess skin flap perfusion and elucidate areas of future necrosis by means of a standardized critical perfusion threshold. Five animal groups (negative controls, n=4; positive controls, n=5; chemotherapy group, n=5; radiation group, n=5; chemoradiation group, n=5) underwent pre-flap treatments two weeks prior to undergoing random pattern dorsal fasciocutaneous flaps with a length to width ratio of 2:1 (3 x 1.5 cm). Flap perfusion was assessed via laser-assisted indocyanine green dye angiography and compared to standard clinical assessment for predictive accuracy of flap necrosis. For estimating flap-failure, clinical prediction achieved a sensitivity of 79.3% and a specificity of 90.5%. When average flap perfusion was more than three standard deviations below the average flap perfusion for the negative control group at the time of the flap procedure (144.3+/-17.05 absolute perfusion units), laser-assisted indocyanine green dye angiography achieved a sensitivity of 81.1% and a specificity of 97.3%. When absolute perfusion units were seven standard deviations below the average flap perfusion for the negative control group, specificity of necrosis prediction was 100%. Quantitative absolute perfusion units can improve specificity for intraoperative prediction of viable tissue. Using this strategy, a positive predictive threshold of flap failure can be standardized for clinical use.
The changing role of pectoralis major flap in head and neck reconstruction.
Liu, Hin-Lun; Chan, Jimmy Yu-Wai; Wei, William Ignace
2010-11-01
Although pectoralis major flap (PM flap) has been used as the workhorse flap in head and neck reconstruction, its use in head and neck defects seems to fall out of favour in the era of free tissue transfer. The aim of this review is to find out the role of PM flap in modern head and neck surgery. Medical records of patients who underwent PM flap reconstruction for head and neck defect in our division were reviewed. The age, gender, flap type, indication and complication rate were described. Between January 1998 and December 2008, 202 PM flaps were used for head and neck reconstruction in 192 patients. In the early study period (1998-June 2003), out of the 119 PM flap reconstructions, 106 (89%) were performed for immediate reconstruction after resection of head and neck tumour, while 10 (8%) were performed as salvage procedures for complication after tumour resection e.g. failure of free flap, pharyngocutaneous fistula. In the late study period (July 2003-2008), out of the 83 PM flap reconstructions, 58 (70%) were performed for immediate reconstruction, while 24 (29%) were performed as salvage procedures. For immediate reconstruction after tumour extirpation, 51 flaps (48%) were performed for reconstruction of the tongue in the early study period, while only 14 (24%) were performed in the late study period. The number of PM flap used for immediate reconstruction for other head and neck defects remained relatively static throughout the two study periods. Over the study period, there were 10 (5%) cases of partial flap necrosis and 2 (1%) total flap loss, making the overall flap necrosis rate 6%. In the era of free tissue transfer, the role of PM flap in head and neck surgery has shifted from immediate reconstruction to salvage operation. However, PM flap still has an unique role in the repair of certain head and neck defects.
Forner, D; Phillips, T; Rigby, M; Hart, R; Taylor, M; Trites, J
2016-02-05
In Canada, 4,400 cases of oral cancer are diagnosed yearly. Surgical resection is a key component of treatment in many of these cancers. Reconstruction of defects, with the goal of preserving function, is of utmost importance. Several choices are possible for reconstruction of larger defects, including both free and pedicled flaps. Free flap reconstruction is reliable and effective, but requires additional personnel and peri-operative resources. Pedicled flaps remain an important alternative to free flaps, and are less resource intensive. This paper reviews our inaugural experience with the submental island flap (SIF) and compares costs incurred to a matched cohort of oral cancer patients reconstructed with forearm free flaps. Charts of patients who underwent SIF and RFFF reconstruction from January 1st 2013 to April 1st 2015 were retrospectively examined. Associated costs were obtained via online database and previously reported costs at the study institution. Mean length of ICU stay in glossectomy RFFF reconstruction was 4.7 days. Only one patient required ICU stay for one night in the SIF group. Mean length of hospital stay was not significantly different in SIF patients vs RFFF patients (12.4 vs 15.4 days, p > 0.05). Mean operative time was significantly lower in the SIF group compared to the RFFF group (347 vs 552 min, p < 0.05). Total mean intraoperative costs were found to be $4780.59 for RFFF operations, versus $2307.94 for SIF. Total mean cost of post-operative stay was $18158.40 in the SIF group and $43617.60 in the RFFF group. Total cost savings were therefore $27931.85 per patient for the SIF group. We have demonstrated the use of the submental island flap as an alternative to radial forearm free flaps, showing both decreased hospital costs and comparable patient outcomes. Pedicled flaps are making a resurgence in head and neck reconstruction, and the submental island flap offers an excellent alternative to more labour intensive and costly free
Multiple-digit resurfacing using a thin latissimus dorsi perforator flap.
Kim, Sang Wha; Lee, Ho Jun; Kim, Jeong Tae; Kim, Youn Hwan
2014-01-01
Traumatic digit defects of high complexity and with inadequate local tissue represent challenging surgical problems. Recently, perforator flaps have been proposed for reconstructing large defects of the hand because of their thinness and pliability and minimal donor site morbidity. Here, we illustrate the use of thin latissimus dorsi perforator flaps for resurfacing multiple defects of distal digits. We describe the cases of seven patients with large defects, including digits, circumferential defects and multiple-digit defects, who underwent reconstruction with thin latissimus dorsi perforator flaps between January 2008 and March 2012. Single-digit resurfacing procedures were excluded. The mean age was 56.3 years and the mean flap size was 160.4 cm(2). All the flaps survived completely. Two patients had minor complications including partial flap loss and scar contracture. The mean follow-up period was 11.7 months. The ideal flap for digit resurfacing should be thin and amenable to moulding, have a long pedicle for microanastomosis and have minimal donor site morbidity. Thin flaps can be harvested by excluding the deep adipose layer, and their high pliability enables resurfacing without multiple debulking procedures. The latissimus dorsi perforator flap may be the best flap for reconstructing complex defects of the digits, such as large, multiple-digit or circumferential defects, which require complete wrapping of volar and dorsal surfaces. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Naringin improves random skin flap survival in rats.
Cheng, Liang; Chen, Tingxiang; Tu, Qiming; Li, Hang; Feng, Zhenghua; Li, Zhijie; Lin, Dingsheng
2017-11-07
Random-pattern flap transfer is commonly used to treat soft-tissue defects. However, flap necrosis remains a serious problem. Naringin accelerates angiogenesis by activating the expression of vascular endothelial growth factor (VEGF). In the present study, we investigated whether naringin improves the survival of random skin flaps. Compared with controls, the naringin-treated groups exhibited significantly larger mean areas of flap survival, significantly increased SOD activity and VEGF expression, and significantly reduced MDA level. Hematoxylin and eosin (HE) staining revealed that naringin promoted angiogenesis and inhibited inflammation. "McFarlane flap" models were established in 90 male Sprague-Dawley (SD) rats divided into three groups: a 40 mg/kg control group (0.5 % sodium carboxymethylcellulose), a 40 mg/kg naringin-treated group, and an 80 mg/kg naringin-treated group. The extent of necrosis was measured 7 days later, and tissue samples were subjected to histological analysis. Angiogenesis was evaluated via lead oxide-gelatin angiography, immunohistochemistry, and laser Doppler imaging. Inflammation was evaluated by measurement of serum TNF-α (tumor necrosis factor-α) and IL-6 (interleukin-6) levels. Oxidative stress was assessed by measuring superoxide dismutase (SOD) activity and the malondialdehyde (MDA) level. Naringin improved random skin flap survival.
The inferior turbinate flap in skull base reconstruction
2013-01-01
Background As the indications for expanded endonasal approaches continue to evolve, alternative reconstructive techniques are needed to address increasingly complex surgical skull base defects. In the absence of the nasoseptal flap, we describe our experience with the posterior pedicle inferior turbinate flap (PPITF) in skull base reconstruction. Design Case series. Setting Academic tertiary care centre. Methods Patients who underwent reconstruction of the skull base with the PPITF were identified. Medical records were reviewed for demographic, presentation, treatment, follow-up, surgical and outcomes data. Main outcome measures Flap survival, adequacy of seal, and complications. Results Two patients with residual/recurrent pituitary adenomas met the inclusion criteria. The nasoseptal flap was unavailable in each case due to a prior septectomy. Salvage of the original nasoseptal flap was not possible, as it did not provide adequate coverage of the resultant defect due to contraction from healing. All PPITFs healed uneventfully and covered the entire defect. No complications were observed in the early post-operative period. Endoscopic techniques and limitations of the PPITF are also discussed. Conclusions Our clinical experience supports the PPITF to be a viable alternative for reconstruction of the skull base in the absence of the nasoseptal flap. PMID:23663897
Clinical application of scrotal flap on penis lengthening.
Zhuo, Qinqiang; Li, Shirong; Wu, Julong; Wang, Zhenxiang; Yang, Dongyun; Tao, Ling
2009-03-01
To investigate the clinical application of the scrotal flap on penis lengthening. One hundred and fifty-two patients were operated using the scrotal flap from July 1998 to January 2008 at the Department of Plastic and Aesthetic, Surgery Southwest Hospital, Chongqing, China. The procedure consisted of designing a positive sign shaped incision 1.5cm above the root of the penis, dissect and release the superficial suspensory ligament and part of the deep suspensory ligament, then cover the elongated cavernosum with proper scrotal flap. Six-month to 5-year follow-up showed that all patients were satisfied with the good contour and function of the penis. The operation was successful. The method of using scrotal flap on penis lengthening has the following advantages: simple operation, reliable blood supply of the flap, one-stage operation, and satisfactory postoperative results. It is a preferable operation technique for penis lengthening.
Postoperative morphine requirements of free TRAM and DIEP flaps.
Kroll, S S; Sharma, S; Koutz, C; Langstein, H N; Evans GRD; Robb, G L; Chang, D W; Reece, G P
2001-02-01
In a review of the charts of 158 patients who had undergone breast reconstruction with free transverse rectus abdominis musculocutaneous (TRAM) or deep inferior epigastric perforator (DIEP) flaps and who were treated for postoperative pain with morphine administered by a patient-controlled analgesia pump, the total dose of morphine administered during hospitalization for the flap transfer was measured. Patients whose treatment was supplemented by other intravenous narcotics were excluded from the study. The mean amount of morphine per kilogram required by patients who had reconstruction with DIEP flaps (0.74 mg/kg, n = 26) was found to be significantly less than the amount required by patients who had reconstruction with TRAM flaps (1.65 mg/kg; n = 132; p < 0.001). DIEP flap patients also remained in the hospital less time (mean, 4.73 days) than did free TRAM flap patients (mean, 5.21 days; p = 0.026), but the difference was less than one full hospital day. It was concluded that the use of the DIEP flap does reduce the patient requirement for postoperative pain medication and therefore presumably reduces postoperative pain. It may also slightly shorten hospital stay.
NASA Technical Reports Server (NTRS)
Wentz, W. H., Jr.
1977-01-01
Two dimensional wind tunnel tests were conducted for the GA(W)-2 airfoil section with: 20% aileron, 25% slotted flap; 30% Fowler flap, and 10% slot-lip spoiler. All tests were conducted at a Reynolds number of 2,200,000 and a Mach Number of 0.13. In addition to force measurements, tuft studies were conducted for the slotted and Fowler flap configurations. Aileron and spoiler hinge moments were obtained by integration of surface pressure measurements. Tests results show that a value of 3.82 was obtained with 30% Fowler flap. Aileron control effectiveness and hinge moments were similar to other airfoils. The slot-lip spoiler provided powerful, positive roll control at all flap settings.
Water Tunnel Studies of Dynamic Wing Flap Effects
2016-06-01
applications where dynamic flaps have been studied are in the active elevon rotor and wind turbines . Any analytical or computational study needs to be...observed here that most of these pertain to other applications such as rotorcraft and wind turbine flow control. At times, a Gurney flap has been for...the flap-slices used. Source: [12]. .......................14 Figure 6. NACA 2212 at wind tunnel section. Source: [8
Free style perforator based propeller flaps: Simple solutions for upper extremity reconstruction!
Panse, Nikhil; Sahasrabudhe, Parag
2014-01-01
The introduction of perforator flaps by Koshima et al. was met with much animosity in the plastic surgery fraternity. The safety concerns of these flaps following the intentional twist of the perforators have prevented widespread adoption of this technique. Use of perforator based propeller flaps in the lower extremity is gradually on the rise, but their use in upper extremity reconstruction is infrequently reported, especially in the Indian subcontinent. We present a retrospective series of 63 free style perforator flaps used for soft tissue reconstruction of the upper extremity from November 2008 to June 2013. Flaps were performed by a single surgeon for various locations and indications over the upper extremity. Patient demographics, surgical indication, defect features, complications and clinical outcome are evaluated and presented as an uncontrolled case series. 63 free style perforator based propeller flaps were used for soft tissue reconstruction of 62 patients for the upper extremity from November 2008 to June 2013. Of the 63 flaps, 31 flaps were performed for trauma, 30 for post burn sequel, and two for post snake bite defects. We encountered flap necrosis in 8 flaps, of which there was complete necrosis in 4 flaps, and partial necrosis in four flaps. Of these 8 flaps, 7 needed a secondary procedure, and one healed secondarily. Although we had a failure rate of 12-13%, most of our failures were in the early part of the series indicative of a learning curve associated with the flap. Free style perforator based propeller flaps are a reliable option for coverage of small to moderate sized defects. Therapeutic IV.
Force Generation by Flapping Foils
NASA Astrophysics Data System (ADS)
Bandyopadhyay, P. R.; Donnelly, M.
1996-11-01
Aquatic animals like fish use flapping caudal fins to produce axial and cross-stream forces. During WW2, German scientists had built and tested an underwater vehicle powered by similar flapping foils. We have examined the forces produced by a pair of flapping foils. We have examined the forced produced by a pair of flapping foils attached to the tail end of a small axisymmetric cylinder. The foils operate in-phase (called waving), or in anti-phase (called clapping). In a low-speed water tunnel, we have undertaken time-dependent measurements of axial and cross-stream forces and moments that are exerted by the vortex shedding process over the entire body. Phase-matched LDV measurements of vorticity-velocity vectors, as well as limited flow visualization of the periodic vortex shedding process have also been carried out. The direction of the induced velocity within a pair of shed vortices determines the nature of the forces produced, viz., thrust or drag or cross-stream forces. The clapping mode produces a widely dispersed symmetric array of vortices which results in axial forces only (thrust and rag). On the other hand, the vortex array is staggered in the waving mode and cross-stream (maneuvering) forces are then generated.
Li, Chun-Chang; Chang, Shun-Cheng; Fu, Ju-Peng; Tzeng, Yuan-Sheng; Wang, Chih-Hsing; Chen, Tim-Mo; Chen, Shyi-Gen
2013-12-01
Surgical reconstruction of trochanteric sores remains a formidable task for plastic surgeons. Diverse types of flaps have been proposed for use in this situation, each with particular advantages and limitations. This study aimed to compare the surgical outcomes between the hatchet-shaped tensor fascia lata (TFL) flap and the pedicle anterior lateral thigh (ALT) flap in treatment of trochanteric sores. Forty-eight patients with trochanteric sores were operated on under spinal or general anesthesia using TFL or ALT flaps between August 2007 and November 2010. In the TFL group, 26 hatchet-shaped TFL musculocutaneous flaps were performed on 24 patients. In the ALT group, 25 pedicle ALT musculocutaneous flaps were performed on 24 patients. Surgical outcomes were retrospectively analyzed. No significant difference was detected between the TFL and ALT groups in terms of age, preoperative disease period, obesity (body mass index), American Society of Anesthesiologists score, comorbidity, the defect size, follow-up time, and complication rate. The recurrence rate and the flap size were significantly higher in the TFL group than in the ALT group (P = 0.022; P < 0.001). The operation time was longer in the ALT group (P < 0.001). The pedicle ALT flap is a more effective treatment than the TFL flap for the surgical management of trochanteric sores. The hatchet-shaped TFL flap should be reserved for the reconstruction of recurrent trochanteric sores or for use in the critically ill patient who cannot tolerate longer anesthesia and operation time.
Paramuscular perforators in DIEAP flap for breast reconstruction.
Pons, Gemma; Masia, Jaume; Sanchez-Porro, Lídia; Larrañaga, Jose; Clavero, Juan Angel
2014-12-01
One of the main steps in perforator flap surgery is to identify the dominant perforator. Using multidetector row computed tomography (MDCT) for the preoperative planning of deep inferior epigastric artery perforator (DIEAP) flap surgery, we identified a perforator with a large caliber, an excellent location in the middle abdominal region, and a totally extramuscular trajectory in a significant number of patients. We describe the frequency of this perforator and determine its characteristics. We conducted a retrospective study of 482 patients who underwent 526 DIEAP flaps for breast reconstruction from October 2003 to October 2011. Mean age at surgery was 51.3 years old. A preoperative MDCT of abdominal vascularization was performed in all patients. MDCT identified a dominant perforator with a paramuscular course in 12.4% of abdominal walls. In all cases, it was located in the midline and emerged directly from the deep inferior epigastric system. Its mean caliber was 1.9 mm. The flap was harvested based on this perforator in all these patients, and mean harvest time was 51 minutes. The characteristics of this perforator made dissection easier and reduced morbidity at the donor site. There were no flap losses and the only complications were minor. We located a paramuscular perforator in 12.4% of patients undergoing breast reconstruction with abdominal perforator flaps. Its morphological features and extramuscular course make it the perforator of choice in DIEAP flap surgery.
Edaravone enhances the viability of ischemia/reperfusion flaps.
Zhang, Dong-Yi; Kang, Shen-Song; Zhang, Zheng-Wen; Wu, Rui
2017-02-01
The purpose of the experiment was to study the efficacy of edaravone in enhancing flap viability after ischemia/reperfusion (IR) and its mechanism. Forty-eight adult male SD rats were randomly divided into 3 groups: control group (n=16), IR group (n=16), and edaravone-treated IR group (n=16). An island flap at left lower abdomen (6.0 cm×3.0 cm in size), fed by the superficial epigastric artery and vein, was created in each rat of all the three groups. The arterial blood flow of flaps in IR group and edaravone-treated IR group was blocked for 10 h, and then the blood perfusion was restored. From 15 min before reperfusion, rats in the edaravone-treated IR group were intraperitoneally injected with edaravone (10 mg/kg), once every 12 h, for 3 days. Rats in the IR group and control group were intraperitoneally injected with saline, with the same method and frequency as the rats in the edaravone-treated IR group. In IR group and edaravone-treated IR group, samples of flaps were harvested after reperfusion of the flaps for 24 h. In the control group, samples of flaps were harvested 34 h after creation of the flaps. The content of malondialdehyde (MDA) and activity of superoxide dismutase (SOD) were determined, and changes in organizational structure and infiltration of inflammatory cells were observed by hematoxylin-eosin (HE) staining, apoptotic cells of vascular wall were marked by terminal deoxynucleotidyl transferase-mediated dUTP nick-end labeling (TUNEL) assay, and the apoptotic rate of cells in vascular wall was calculated. The ultrastructural changes of vascular endothelial cells were observed by transmission electron microscopy (TEM). Seven days after the operation, we calculated the flap viability of each group, and marked vessels of flaps by immunohistochemical staining for calculating the average number of subcutaneous vessels. The results showed that the content of MDA, the number of multicore inflammatory cells and apoptotic rate of cells in vascular wall
Chi, Zhenglin; Chen, Yiheng; Chu, Tinggang; Gao, Weiyang; Li, Zhijie; Yan, Hede; Song, Yonghuan
2018-02-01
The conventional procedure of the sural neuro-fasciocutaneous flap enables the supply of blood and venous drainage by increasing the width of the adipofascial tissue and preserving tiny venous return routes. Moreover, skin graft is a common method for donor site closure, which may lead to some complications and influence the aesthetic appearance. We report modifications for a distally based sural neuro-fasciocutaneous perforator flap and a relaying flap for donor site closure without skin graft. Twelve patients undergoing the modified flap for foot and ankle reconstruction were included in this study between 2014 and 2016. A peroneal-based perforator, a superficial vein, and the vascular axis of the sural nerve were included in the pedicle. A Z-shape skin incision was performed to explore the perforator vessels and a relaying island perforator flap was used to close the donor site. All flaps survived completely without necrosis. The area of the flaps ranged from 16 × 8 cm to 30 × 15 cm. The diameter width of the pedicle ranged from 1.0 to 2.0 cm. A relaying perforator island flap was used in 10 cases for donor site closure and no skin graft was performed. There were no serious donor site complications. All patients were satisfied with the aesthetic outcome postoperatively at the final follow-up. The distally based sural neuro-fasciocutaneous perforator flap is considered a reliable method for foot and ankle reconstruction. The modification for flap pedicle and donor site closure method without skin graft should be recommended. Copyright © 2017. Published by Elsevier Ltd.
Paydarfar, Joseph A; Patel, Urjeet A
2011-01-01
To compare intraoperative, postoperative, and functional results of submental island pedicled flap (SIPF) against radial forearm free flap (RFFF) reconstruction for tongue and floor-of-mouth reconstruction. Multi-institutional retrospective review. Academic tertiary referral center. Consecutive patients from February 2003 to December 2009 undergoing resection of oral tongue or floor of mouth followed by reconstruction with SIPF or RFFF. Two groups: SIPF vs RFFF. Duration of operation, hospital stay, surgical complications, and speech and swallowing function. The study included 60 patients, 27 with SIPF reconstruction and 33 with RFFF reconstruction. Sex, age, and TNM stage were similar for both groups. Mean flap size was smaller for SIPF (36 cm²) than for RFFF (50 cm²) (P < .001). Patients undergoing SIPF reconstruction had shorter operations (mean, 8 hours 44 minutes vs 13 hours 00 minutes; P < .001) and shorter hospitalization (mean, 10.6 days vs 14.0 days; P < .008) compared with patients who underwent RFFF. Donor site, flap-related, and other surgical complications were comparable between groups, as was speech and swallowing function. Reconstruction of oral cavity defects with the SIPF results in shorter operative time and hospitalization without compromising functional outcomes. The SIPF may be a preferable option in reconstruction of oral cavity defects less than 40 cm².
Desferrioxamine: a practical method for improving neovascularization of prefabricated flaps.
Li, Bin; Li, Hua; Jin, Rui; Cheng, Chen; Wang, Jing; Zhu, Hainan; Zan, Tao; Li, Qingfeng; Hao, Lijun
2015-02-01
Prefabricated flaps are an ideal alternative to repair massive and complex tissue defects. Nevertheless, the risk of necrosis due to unpredictable blood supplies is a major obstacle to the application of prefabricated flaps. The survival of a prefabricated flap depends on the neovascularization between the vascular carrier and the donor tissue. Here, we proposed that the iron chelator, desferrioxamine (DFX), owned therapeutic effects that promoted the neovascularization of prefabricated flaps. An abdominal prefabricated flap model was created in rats via a 2-stage operation. The rats were allocated into 4 groups as follows: 2 groups of rats received DFX treatments during the first or the second stage of the operation, respectively; 1 group of rats received a delay procedure 1 week before the second operation; and the final group was used as a blank control. Flap survival rates and capillary densities were evaluated between groups. The influence of DFX on the dermal fibroblasts was also studied in vitro. Desferrioxamine treatment during the first stage of the operation greatly increased flap survival rate compared to the blank control. The results were similar to those produced by the delay treatment. The vessel count results were consistent with the flap survival rate findings. In vitro, DFX treatment up-regulated the expression levels of several angiogenic factors in the dermal fibroblasts. Nevertheless, DFX treatment during the second stage of the operation was therapeutically detrimental. The application of DFX around the time of vascular carrier implantation greatly promoted neovascularization of prefabricated flaps, but was therapeutically detrimental after the flaps had been elevated.
Efficacy of Liposuction as a Delay Method for Improving Flap Survival.
Orhan, Erkan; Erol, Yağmur Reyyan; Deren, Orgun; Altun, Serdar; Erdoğan, Bülent
2016-12-01
Flaps are often used in repairing tissue defects and partial or full flap loss is still an important morbidity cause. Several techniques have been tried to increase flap circulation but none of these could replace the delay technique. Our goal in this study is to show the efficacy of liposuction in delay of dorsal rat cutaneous flaps and improvement in flap survival. Twenty-four Wistar rats were used. The rats in group 1 received 9 × 3-sized caudally-based random pattern skin flaps. In group 2, liposuction was done under the tissue island spotted as the flap and after 14 days, standard flap surgery was done. In group 3, surgical delay was done and after 14 days, standard flap surgery was done. In group 4, liposuction was done under the tissue island spotted as the flap and standard flap surgery was done right after the liposuction. The rate of necrotic tissue in group 3 (surgical delay; mean % 13.7) was less than the rate in group 2 (liposuction delay; mean % 15.1), although the difference was not statistically significant. The necrosis rates in group 3 (surgical delay) and group 2 (liposuction delay) were less than the rates in both group 1 (only flap; mean % 41.5) and group 4 (liposuction flap; mean % 40.0) and this difference was statistically significant (p < 0.0001). Liposuction can be an alternative to surgical delay as a less invasive method in the clinic. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Hunsinger, Vincent; Lhuaire, Martin; Haddad, Kevin; Wirz, Francesco-Saverio; Abedalthaqafi, Samah; Obadia, Déborah; Derder, Mohamed; Marchac, Alexandre; Benjoar, Marc David; Hivelin, Mikael; Lantieri, Laurent
2018-06-02
The volume of the profunda femoris artery perforator (PAP) flap limits its indications to small- and medium-sized breast reconstructions after modified radical mastectomy for cancer. We report a modified PAP flap design, including not only a vertical extension that increases its volume but also the skin surface, which suits larger breasts requiring immediate or delayed breast reconstructions and compare the results with our horizontal skin paddle PAP flap experience. In our center between November 2014 and November 2016, 51 consecutive patients underwent a PAP flap breast reconstruction following breast cancer. A retrospective analysis on the collected data was performed to compare 34 patients with a bra cup smaller than C who underwent 41 horizontal PAP flap procedures, with those ( n = 17) of a bra cup greater than or equal to C who underwent 21 fleur-de-lys PAP flap procedures. Demographic, anthropometric, flap and surgical characteristics, postoperative complication rates, and hospital stay were compared between the two groups. The average flap weight was 480 g (range: 340-735 g) for the fleur-de-lys PAP flap group compared with 222 g (range: 187-325 g) for the horizontal PAP flap procedure ( p < 0.001). The mean flap dimensions were 25 × 18 cm for the fleur-de-lys PAP flap group compared with 25 × 7 cm in the horizontal PAP flap group. No flap failure was observed in the fleur-de-lys PAP flap group compared with two flap failures secondary to venous thrombosis in the horizontal PAP flap group ( NS ). Three patients (14%) experienced delayed healing at the donor site compared with four patients (10%) in the horizontal PAP flap group ( NS ). The fleur-de-lys skin paddle design not only allows an increase of the horizontal PAP flap volume, but also increases the skin surface, with an acceptable donor site morbidity. For medium- or large-sized breasts, the fleur-de-lys PAP flap seems to be ideal when a DIEP flap
Clinical applications of perforator-based propeller flaps in upper limb soft tissue reconstruction.
Ono, Shimpei; Sebastin, Sandeep J; Yazaki, Naoya; Hyakusoku, Hiko; Chung, Kevin C
2011-05-01
A propeller flap is an island flap that moves from one orientation to another by rotating around its vascular axis. The vascular axis is stationary, and flap movement is achieved by revolving on this axis. Early propeller flaps relied on a thick, subcutaneous pedicle to maintain vascularity, and this limited the flap rotation to 90°. With increasing awareness of the location and the vascular territory perfused by cutaneous perforators, it is now possible to design propeller flaps based on a single perforator, so-called "perforator-based propeller flaps." These flaps permit flap rotation up to 180°. We present the results of upper limb soft tissue reconstruction using perforator-based propeller flaps. We constructed a treatment strategy based on the location of the soft tissue defect and the perforator anatomy for expedient wound coverage in 1 stage. All perforator-based propeller flaps derived from 3 institutions that were used for upper limb soft tissue reconstruction were retrospectively analyzed. The parameters studied included the size and location of the defect, the perforator that was used, the size and shape of the flap, the direction (ie, clockwise or counter-clockwise) of flap rotation, the degree of twisting of the perforator, the management of the donor site (ie, linear closure or skin grafting), and flap survival (recorded as the percentage of the flap area that survived). Twelve perforator-based propeller flaps were used to reconstruct upper limb soft tissue defects in 12 patients. Six different perforators were used as vascular pedicles. The donor defects of 11 flaps could be closed primarily. One flap was partially lost in a patient with electrical burns. Perforator-based propeller flaps provide a reliable option for covering small- to medium-size upper limb soft tissue defects. Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
50 CFR Figure 16 to Part 223 - Escape Opening and Flap Dimensions for the Double Cover Flap TED
Code of Federal Regulations, 2012 CFR
2012-10-01
... 50 Wildlife and Fisheries 10 2012-10-01 2012-10-01 false Escape Opening and Flap Dimensions for the Double Cover Flap TED 16 Figure 16 to Part 223 Wildlife and Fisheries NATIONAL MARINE FISHERIES SERVICE, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE MARINE MAMMALS THREATENED...
Valerio, Ian; Green, J Marshall; Sacks, Justin M; Thomas, Shane; Sabino, Jennifer; Acarturk, T Oguz
2015-01-01
Large segmental bone and composite tissue defects often require vascularized osseous flaps for definitive reconstruction. However, failed osseous flaps due to inadequate perfusion can lead to significant morbidity. Utilization of indocyanine green (ICG) fluorescence angiography has been previously shown to reliably assess soft tissue perfusion. Our group will outline the application of this useful intraoperative tool in evaluating the perfusion of vascularized osseous flaps. A retrospective review was performed to identify those osseous and/or osteocutaneous bone flaps, where ICG angiography was employed. Data analyzed included flap types, success and failure rates, and perfusion-related complications. All osseous flaps were evaluated by ICG angiography to confirm periosteal and endosteal perfusion. Overall 16 osseous free flaps utilizing intraoperative ICG angiography to assess vascularized osseous constructs were performed over a 3-year period. The flaps consisted of the following: nine osteocutaneous fibulas, two osseous-only fibulas, two scapular/parascapular with scapula bone, two quadricep-based muscle flaps, containing a vascularized femoral bone component, and one osteocutaneous fibula revision. All flap reconstructions were successful with the only perfusion-related complication being a case of delayed partial skin flap loss. Intraoperative fluorescence angiography is a useful adjunctive tool that can aid in flap design through angiosome mapping and can also assess flap perfusion, vascular pedicle flow, tissue perfusion before flap harvest, and flap perfusion after flap inset. Our group has successfully extended the application of this intraoperative tool to assess vascularized osseous flaps in an effort to reduce adverse outcomes related to preventable perfusion-related complications. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Scaglioni, Mario F; Barth, Andrè A; Chen, Yen-Chou
2018-06-19
The primary closure of the vertical posteromedial thigh (vPMT) free flap donor site is very important to minimize donor site morbidity and maximize cosmetic appearance. However, sometimes due to the dimension of the defect, a vPMT flap is wider than the 8-10 cm requirement. The authors report their experience with the third perforator of the profunda femoris artery (PFA) during the vPMT free flap donor-site closure. Between January 2016 and December 2017, 5 patients underwent reconstruction of lower extremity (2 pts.) and head and neck (3 pts.) area with the free vPMT flaps. Attempts to close the vPMT free flap donor site directly failed due to the flaps' width (average: 11 cm) and pedicled perforator flaps based on the third perforator of the PFA at the distal thigh were harvested to close the defect primary without the use of a skin graft. The size of perforator flap based on 3rd perforator of PFA was on average 6 cm × 4 cm (ranged: 4-8 cm × 3-6 cm). In all patients, the third perforator of the PFA was identified and the perforator diameter was on average 2.0 mm (range, 1.8-2.2 mm). All perforators were musculocutaneous and single. The dimensions of the flaps were on average 6 cm × 4 cm (range: 4 to 8 cm × 3 to 6 cm). All flaps healed uneventfully without complications and the patients were satisfied with cosmetic and functional results at 6 months follow-up. The third perforator of the PFA may be an option to ensure primary closure of the PMT flap donor site, when a larger flap for reconstruction is needed with subsequent impossibility to achieve primary closure of the donor site. © 2018 Wiley Periodicals, Inc.
Reconstruction of the vulva with sensate gluteal fold flaps.
Kuokkanen, H; Mikkola, A; Nyberg, R H; Vuento, M H; Kaartinen, I; Kuoppala, T
2013-01-01
Soft-tissue reconstruction of the vulva following resection of malignancies is challenging. The function of perineal organs should be preserved and the reconstructed area should maintain an acceptable cosmetic appearance. Reconstruction with local flaps is usually sufficient in the primary phase after a radical vulvectomy. Numerous flaps have been designed for vulvar reconstruction usually based on circulation from the internal pudendal artery branches. In this paper we introduce our modification of the gluteal fold V-Y advancement flap as a primary reconstruction after a radical vulvectomy. Twenty-two patients were operated with a radical vulvectomy because of vulvar malignancies. The operation was primary in eight and secondary in 14 patients. The reconstruction of the vulva was performed in the same operation for each patient. All flaps survived completely. Wound complications were registered in three patients. Late problems with urinary stream were corrected in two patients. A local recurrence of the malignancy was observed in six patients during the follow-up period. Gluteal fold flap is easy to perform, has a low rate of complications and gives good functional results. Even a large defect can be reconstructed reliably with this method. A gluteal fold V-Y advancement flap is sensate and our modification allows the flap to be transposed with lesser dissection as presented before.
Reverse-flow retroauricular island flap in facial reconstruction.
Benlier, Erol; Top, Husamettin; Cinar, Can; Yazar, Sukru; Aygit, A Cemal; Cetinkale, Oguz
2007-12-01
Reconstruction of facial skin defects requires good-quality skin cover to satisfy aesthetic expectations of patient, especially when the skin defect is on the uncovered area of the face. Limitations in the available local tissue and donor-site morbidity restrict the options. In an effort to solve these problems, we have begun to use a subcutaneous pedicled retroauricular reverse-flow flap. Between January 1997 and December 2005, reverse-flow subcutaneous pedicled retroauricular island flap was used to cover facial defects in 12 patients who underwent surgical excision of skin tumor. The patients ranged in age from 44 to 81 years with a mean age of 58 years. Only one case experienced a superficial necrosis in the distal one-quarter part of the flap. The functional and aesthetic results were satisfactory for both patients and surgeons, and no tumor recurrence was observed during the 12 to 28 months (mean, 18.8 months) follow-up period. This flap can be used reliably for the reconstruction of facial skin defects of small and medium size. The preference of frontal branch pedicled flap enables more distal facial area defects to be covered, such as dorsal nasal, nasolabial, and upper lip, than flaps based on parietal branch.
FAMM Flap in Reconstructing Postsurgical Nasopharyngeal Airway Stenosis
Nangole, Ferdinand Wanjala; Khainga, Stanley Ominde
2014-01-01
Introduction. Postsurgical nasopharyngeal airway stenosis can be a challenge to manage. The stenosis could be as a result of any surgical procedure in the nasopharyngeal region that heals extensive scarring and fibrosis. Objective. To evaluate patients with nasopharyngeal stenosis managed with FAMM flap. Study Design. Prospective study of patients with nasopharyngeal stenosis at the Kenyatta National Hospital between 2010 and 2013 managed with FAMM flap. Materials and Methods. Patients with severe nasopharyngeal airway stenosis were reviewed and managed with FAMM flaps at the Kenyatta National Hospital. Postoperatively they were assessed for symptomatic improvement in respiratory distress, patency of the nasopharyngeal airway, and donor site morbidity. Results. A total of 8 patients were managed by the authors in a duration of 4 years with nasopharyngeal stenosis. Five patients were managed with unilateral FAMM flaps in a two-staged surgical procedure. Four patients had complete relieve of the airway obstruction with a patent airway created. One patient had a patent airway created though with only mild improvement in airway obstruction. Conclusion. FAMM flap provides an alternative in the management of postsurgical severe nasopharyngeal stenosis. It is a reliable flap that is easy to raise and could provide adequate epithelium for the stenosed pharynx. PMID:25328699
Piloted simulation study of two tilt-wing flap control concepts, phase 2
NASA Technical Reports Server (NTRS)
Birckelbaw, Lourdes G.; Corliss, Lloyd D.; Hindson, William S.; Churchill, Gary B.
1994-01-01
A two phase piloted simulation study has been conducted in the Ames Vertical Motion Simulator to investigate alternative wing and flap controls for tilt-wing aircraft. This report documents the flying qualities results and findings of the second phase of the piloted simulation study and describes the simulated tilt-wing aircraft, the flap control concepts, the experiment design and the evaluation tasks. The initial phase of the study compared the flying qualities of both a conventional programmed flap and an innovative geared flap. The second phase of the study introduced an alternate method of pilot control for the geared flap and further studied the flying qualities of the programmed flap and two geared flap configurations. In general, the pilot ratings showed little variation between the programmed flap and the geared flap control concepts. Some differences between the two control concepts were noticed and are discussed in this report. The geared flap configurations had very similar results. Although the geared flap concept has the potential to reduce or eliminate the pitch control power requirements from a tail rotor or a tail thruster at low speeds and in hover, the results did not show reduced tail thruster pitch control power usage with the geared flap configurations compared to the programmed flap configuration. The addition of pitch attitude stabilization in the second phase of simulation study greatly enhanced the aircraft flying qualities compared to the first phase.
Bed isolation in experimental flap studies in rats: a dispensable procedure.
Heimer, Sina; Schaefer, Amelia; Mueller, Wolf; Lass, Ulrike; Gebhard, Martha M; Germann, Günter; Leimer, Uwe; Köllensperger, Eva; Reichenberger, Matthias A
2013-03-01
Review of the literature regarding rodent experimental flap models reveals fundamental differences in applied surgical procedures. Although some authors isolate the flap from its wound bed, others do not. This study was planned to investigate to what extent the insertion of a silicone sheet affects physiological wound healing in experimental flap surgery. An extended epigastric adipocutaneous flap (6 × 10 cm) was raised in 16 male Lewis rats. In the control group (group C), flaps were immediately inset without any intervention. In the experimental group (group M), a silicone sheet barrier was placed between the flap and the wound bed. Mean flap survival area and flap perfusion were evaluated. Microvessel density was visualized by immunohistochemistry, and semiquantitative real-time polymerase chain reaction addressed differential gene expression. All animals were investigated on postoperative day 5. Flap survival area and flap perfusion were found to be similar. Immunohistochemistry, however, demonstrated a significantly increased number of CD31-positive small vessels in group C. The insertion of the silicone sheet barrier (group M) was accompanied by a significantly enhanced expression of proinflammatory genes and a suppression of proangiogenic genes. Our results show that although the silicone membrane has no influence on the surgical outcome in terms of flap survival and perfusion, it does lead to significant molecular alterations in pathways involved in physiological wound healing. These alterations are artificially induced by the foreign body material and conceal the true driving forces of the healing process. As the latter might include relevant therapeutic targets to ameliorate surgical results, we regard wound bed isolation as a dispensable procedure in the study of rodent flap models.
Works on theory of flapping wing. [considering boundary layer
NASA Technical Reports Server (NTRS)
Golubev, V. V.
1980-01-01
It is shown mathematically that taking account of the boundary layer is the only way to develop a theory of flapping wings without violating the basic observations and mathematics of hydromechanics. A theory of thrust generation by flapping wings can be developed if the conventional downstream velocity discontinuity surface is replaced with the observed Karman type vortex streets behind a flapping wing. Experiments show that the direction of such vortices is the reverse of that of conventional Karman streets. The streets form by breakdown of the boundary layer. Detailed analysis of the movements of certain birds and insects during flight 'in place' is fully consistent with this theory of the lift, thrust and drag of flapping wings. Further directions for research into flight with flapping wings are indicated.
Reconstruction of lower face defect or deformity with submental artery perforator flaps.
Shi, Cheng-li; Wang, Xian-cheng
2012-07-01
Reconstruction of lower face defects or deformity often presents as a challenge for plastic surgeons. Many methods, including skin graft, tissue expander, or free flap are introduced. Submental artery perforator flaps have been used in the reconstruction of defects or deformities of the lower face. Between August 2006 and December 2008, 22 patients with lower face defects or deformity underwent reconstruction with pedicled submental artery perforator flaps. Their age ranged between 14 and 36 years. The perforator arteries were detected and labeled with a hand-held Doppler flowmeter. The size of flaps ranged from 4 × 6 to 6 × 7 cm, and the designed flaps included the perforator artery. All the flaps survived well, except 1 flap which resulted in partial necrosis in distal region and healed after conservative therapy. No other complication occurred with satisfactory aesthetic appearance of the donor site. The submental artery perforator flap is a thin and reliable flap with robust blood supply. This flap can reduce donor-site morbidity significantly and is a good choice for reconstructive surgery of lower face.
50 CFR Figure 16 to Part 223 - Escape Opening and Flap Dimensions for the Double Cover Flap TED
Code of Federal Regulations, 2011 CFR
2011-10-01
... 50 Wildlife and Fisheries 9 2011-10-01 2011-10-01 false Escape Opening and Flap Dimensions for the Double Cover Flap TED 16 Figure 16 to Part 223 Wildlife and Fisheries NATIONAL MARINE FISHERIES SERVICE, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE MARINE MAMMALS THREATENED MARINE...
A dynamical system for interacting flapping swimmers
NASA Astrophysics Data System (ADS)
Oza, Anand; Ramananarivo, Sophie; Ristroph, Leif; Shelley, Michael
2015-11-01
We present the results of a theoretical investigation into the dynamics of interacting flapping swimmers. Our study is motivated by the recent experiments of Becker et al., who studied a one-dimensional array of self-propelled flapping wings that swim within each other's wakes in a water tank. They discovered that the system adopts certain ``schooling modes'' characterized by specific spatial phase relationships between swimmers. To rationalize these phenomena, we develop a discrete dynamical system in which the swimmers are modeled as heaving airfoils that shed point vortices during each flapping cycle. We then apply our model to recent experiments in the Applied Math Lab, in which two tandem flapping airfoils are free to choose both their speed and relative positions. We expect that our model may be used to understand how schooling behavior is influenced by hydrodynamics in more general contexts. Thanks to the NSF for its support.
Aesthetic Penoscrotal Resurfacing: Creating Propeller Flaps from Gluteal Folds.
Han, So-Eun; Kim, Eun-Ji; Sung, Hyun Hwan; Pyon, Jai-Kyong
2018-04-01
Reconstruction of extensive penoscrotal defects is a surgical challenge. Resurfacing defects in highly complex three-dimensional structures and restoring their function are an essential part of the reconstruction of penoscrotal regions. We describe a technique using internal pudendal artery perforator (IPAP) pedicled propeller flaps created from the gluteal fold. This could be a reliable surgical option that maintains a natural looking scrotal pouch with minimal donor site morbidity and optimal sexual activity. We retrospectively reviewed data for 10 consecutive patients who had undergone penoscrotal reconstruction using IPAP pedicled propeller flaps between January 2011 and March 2015. The IPAP was identified using a hand-held Doppler ultrasound device. This was the pivot around which the flap was internally rotated more than 90° in a tension-free manner. The long axis of the flap was centred on the gluteal fold to provide a better-orientated donor site scar. Complications and patient satisfaction with respect to size, colour match, scar appearance, and sexual activity were evaluated. Anatomic and aesthetic penoscrotal reconstruction was performed without any major complications in the follow-up period (mean, 19.7 mo). The mean width of the IPAP pedicled propeller flaps was 6.7cm, and the mean length was 11.7cm. Partial distal flap necrosis occurred in only one case, and healed spontaneously. All of the patients were satisfied with the cosmetic and functional results. On the basis of reliable perforators, donor site morbidity, flap thickness, and a better orientated scar, our technique using IPAP pedicled propeller flaps created from the gluteal fold could be a reasonable surgical option for extensive penoscrotal reconstruction. The creation of pedicled propeller flaps using an internal pudendal artery perforator could be a reliable surgical option for reconstruction of extensive penoscrotal defects. The approach yields functional and aesthetically acceptable
14 CFR 23.699 - Wing flap position indicator.
Code of Federal Regulations, 2012 CFR
2012-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.699 Wing flap position indicator. There must be a wing flap position...
14 CFR 23.699 - Wing flap position indicator.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.699 Wing flap position indicator. There must be a wing flap position...
14 CFR 23.699 - Wing flap position indicator.
Code of Federal Regulations, 2014 CFR
2014-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.699 Wing flap position indicator. There must be a wing flap position...
14 CFR 23.699 - Wing flap position indicator.
Code of Federal Regulations, 2011 CFR
2011-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.699 Wing flap position indicator. There must be a wing flap position...
Active Flap Control of the SMART Rotor for Vibration Reduction
NASA Technical Reports Server (NTRS)
Hall, Steven R.; Anand, R. Vaidyanathan; Straub, Friedrich K.; Lau, Benton H.
2009-01-01
Active control methodologies were applied to a full-scale active flap rotor obtained during a joint Boeing/ DARPA/NASA/Army test in the Air Force National Full-Scale Aerodynamic Complex 40- by 80-foot anechoic wind tunnel. The active flap rotor is a full-scale MD 900 helicopter main rotor with each of its five blades modified to include an on-blade piezoelectric actuator-driven flap with a span of 18% of radius, 25% of chord, and located at 83% radius. Vibration control demonstrated the potential of active flaps for effective control of vibratory loads, especially normal force loads. Active control of normal force vibratory loads using active flaps and a continuous-time higher harmonic control algorithm was very effective, reducing harmonic (1-5P) normal force vibratory loads by 95% in both cruise and approach conditions. Control of vibratory roll and pitch moments was also demonstrated, although moment control was less effective than normal force control. Finally, active control was used to precisely control blade flap position for correlation with pretest predictions of rotor aeroacoustics. Flap displacements were commanded to follow specific harmonic profiles of 2 deg or more in amplitude, and the flap deflection errors obtained were less than 0.2 deg r.m.s.
Treatment of ischial pressure sores with double adipofascial turnover flaps.
Lin, Haodong; Hou, Chunlin; Xu, Zhen; Chen, Aiming
2010-01-01
Despite a variety of flap reconstruction options, the ischium remains the most difficult pressure sore site to treat. This article describes the authors' successful surgical procedure for coverage of ischial ulcers using double adipofascial turnover flaps.After debridement, the adipofascial flaps are harvested both cephalad and caudal to the defect. The flaps are then turned over to cover the exposed bone in a manner so as to overlap the 2 flaps. The skin is then closed with sutures in 2 layers. A total of 15 patients with ischial sores were treated using this surgical procedure.The follow-up period ranged from 11 to 159 months, with a mean of 93.6 months. Overall, 86.7% of the flaps (13 of 15) healed primarily. One patient had a recurrent grade II ischial pressure sore again 11 months after the operation. The other 14 patients did not have a recurrence.Treatment of ischial pressure sores with adipofascial turnover flaps provides an easy, minimally invasive procedure, with preservation of future flap options, and a soft-tissue supply sufficient for covering the bony prominence and filling dead space. This technique is a reliable and safe reconstructive modality for the management of minor ischial pressure sores.
Porcine experimental model for perforator flap raising in reconstructive microsurgery.
González-García, José A; Chiesa-Estomba, Carlos M; Álvarez, Leire; Altuna, Xabier; García-Iza, Leire; Thomas, Izaskun; Sistiaga, Jon A; Larruscain, Ekhiñe
2018-07-01
Perforator free flap-based reconstruction of the head and neck is a challenging surgical procedure and needs a steep learning curve. A reproducible mammal large animal model with similarities to human anatomy is relevant for perforator flap raising and microanastomosis. The aim of this study was to assess the feasibility of a swine model for perforator-based free flaps in reconstructive microsurgery. Eleven procedures were performed under general anesthesia in a porcine model, elevating a skin flap vascularized by perforating musculocutaneous branches of the superior epigastric artery to evaluate the relevance of this model for head and neck reconstructive microsurgery. The anterior abdominal skin perforator-based free flap in a swine model irrigated by the superior epigastric artery was elevated in eleven procedures. In six of these procedures, we could perform an arterial and venous microanastomosis to the great vessels located in the base of the neck. The porcine experimental model of superior epigastric artery perforator-based free flap reconstruction offers relevant similarities to the human deep inferior epigastric artery perforator flap. We could demonstrate this model as acceptable for perforator free flap training due to the necessity of perforator and pedicle dissection and transfer to a distant area. Copyright © 2018 Elsevier Inc. All rights reserved.
A lining vomer flap for palate pushback in unilateral cleft palate repair.
Clavin, H D; Owsley, J Q
1978-01-01
A combinaation vomer mucoperiosteal flap and nasal floor mucoperiosteal flap is described which is used to achieve nasal coverage in unilateral cleft palate patients requiring pushbacks. A posteriorly based readily accessible vomer flap is raised on the cleft side and used as nasal lining for the palatal mucoperiosteal flap on the non-cleft side. On the cleft side, a symmetrically sized nasal floor flap is easily elevated under direct vision and used to cover the nasal aspect of the corresponding mucoperiosteal palatal flap.
Dynamic perfusion assessment during perforator flap surgery: an up-to-date
MUNTEAN, MAXIMILIAN VLAD; MUNTEAN, VALENTIN; ARDELEAN, FILIP; GEORGESCU, ALEXANDRU
2015-01-01
Flap monitoring technology has progressed alongside flap design. The highly variable vascular anatomy and the complexity associated with modern perforator flaps demands dynamic, real-time, intraoperative information about the vessel location, perfusion patterns and flap physiology. Although most surgeons still assess flap perfusion and viability based solely on clinical experience, studies have shown that results may be highly variable and often misleading. Poor judgment of intraoperative perfusion leads to major complications. Employing dynamic perfusion imaging during flap reconstruction has led to a reduced complication rate, lower morbidity, shorter hospital stay, and an overall better result. With the emergence of multiple systems capable of intraoperative flap evaluation, the purpose of this article is to review the two systems that have been widely accepted and are currently used by plastic surgeons: Indocyanine green angiography (ICGA) and dynamic infrared thermography (DIRT). PMID:26609259
Tracheal reconstruction with a pleuroperiosteal flap.
Krespi, Y P; Biller, H F; Baek, S M
1983-12-01
Reconstruction of extensive tracheal defects remains a difficult surgical problem. In many experiments restoration of tracheal mucosa by autogenous or homologous soft tissue grafts has usually failed because of rejection or tracheal obstruction. This experimental work employed a two-stage surgical procedure that allowed reconstruction of extensive circumferential full-thickness defects of the trachea. Stage I involved the creation of a vascularized pleuroperiosteal flap that was formed into a rigid tube around a Silastic stent. Stage II consisted of creation of a full-thickness circumferential tracheal defect and repair with the flap in those animals in which a suitable rigid tube had been formed. The results of these experiments argue strongly that a vascularized composite pleuroperiosteal flap can produce an adequate tracheal replacement.
Posttraumatic eyebrow reconstruction with hair-bearing temporoparietal fascia flap
Denadai, Rafael; Raposo-Amaral, Cassio Eduardo; Marques, Frederico Figueiredo; Raposo-Amaral, Cesar Augusto
2015-01-01
The temporoparietal fascia flap has been extensively used in craniofacial reconstructions. However, its use for eyebrow reconstruction has been sporadically reported. We describe a successfully repaired hair-bearing temporoparietal fascia flap after traumatic avulsion of eyebrow. Temporoparietal fascia flap is a versatile tool and should be considered as a therapeutic option by all plastic surgeons. PMID:25993077
Dynamic response of a piezoelectric flapping wing
NASA Astrophysics Data System (ADS)
Kumar, Alok; Khandwekar, Gaurang; Venkatesh, S.; Mahapatra, D. R.; Dutta, S.
2015-03-01
Piezo-composite membranes have advantages over motorized flapping where frequencies are high and certain coupling between bending and twisting is useful to generate lift and forward flight. We draw examples of fruit fly and bumble bee. Wings with Piezo ceramic PZT coating are realized. The passive mechanical response of the wing is characterized experimentally and validated using finite element simulation. Piezoelectric actuation with uniform electrode coating is characterized and optimal frequencies for flapping are identified. The experimental data are used in an empirical model and advanced ratio for a flapping insect like condition for various angular orientations is estimated.
NASA Astrophysics Data System (ADS)
Dougherty, Daniel A.
A wind tunnel tat of a tailless aircraft configuration that has been quipped with a belly-flap control surface, was conducted with the goal of improving the trimmed maximum-lift coefficient. Tailless aircraft have aerodynamic and structural efficiencies that are superior to those of a traditionally configured wing/body/tail aircraft. However, tailless aircraft have a low maximum-lift coefficient such that; when sized for equivalent takeoff performance, the tailless aircraft suffers a large reduction in aerodynamic and structural efficiencies. A Belly-Flap control surface used in combination with wing trailing edge flaps was tested in a wind tunnel with the goal of achieving a longitudinally trimmed solution at a higher maximum lift coefficient. It was determined that, though the Belly-Flap increases the trimmed lift of the tailless configuration at low angles of attack, the maximum lift coefficient is slightly reduced in relation to the controls neutral configuration.
Vortex Flap Technology: a Stability and Control Assessment
NASA Technical Reports Server (NTRS)
Carey, K. M.; Erickson, G. E.
1984-01-01
A comprehensive low-speed wind tunnel investigation was performed of leading edge vortex flaps applied to representative aircraft configurations. A determination was made of the effects of analytically- and empirically-designed vortex flaps on the static longitudinal and lateral-directional aerodynamics, stability, and control characteristics of fighter wings having leading-edge sweep angles of 45 to 76.5 degrees. The sensitivity to several configuration modifications was assessed, which included the effects of flap planform, leading- and trailing-edge flap deflection angles, wing location on the fuselage, forebody strakes, canards, and centerline and outboard vertical tails. Six-component forces and moments, wing surface static pressure distributions, and surface flow patterns were obtained using the Northrop 21- by 30-inch low-speed wind tunnel.
Park, Sung Woo; Oh, Tae Suk; Eom, Jin Sup; Sun, Yoon Chi; Suh, Hyun Suk; Hong, Joon Pio
2015-05-01
The reconstruction of the posterior trunk remains to be a challenge as defects can be extensive, with deep dead space, and fixation devices exposed. Our goal was to achieve a tension-free closure for complex defects on the posterior trunk. From August 2006 to May 2013, 18 cases were reconstructed with multiple flaps combining perforator(s) and local skin flaps. The reconstructions were performed using freestyle approach. Starting with propeller flap(s) in single or multilobed design and sequentially in conjunction with adjacent random pattern flaps such as fitting puzzle. All defects achieved tensionless primary closure. The final appearance resembled a jigsaw puzzle-like appearance. The average size of defect was 139.6 cm(2) (range, 36-345 cm(2)). A total of 26 perforator flaps were used in addition to 19 random pattern flaps for 18 cases. In all cases, a single perforator was used for each propeller flap. The defect and the donor site all achieved tension-free closure. The reconstruction was 100% successful without flap loss. One case of late infection was noted at 12 months after surgery. Using multiple lobe designed propeller flaps in conjunction with random pattern flaps in a freestyle approach, resembling putting a jigsaw puzzle together, we can achieve a tension-free closure by distributing the tension to multiple flaps, supplying sufficient volume to obliterate dead space, and have reliable vascularity as the flaps do not need to be oversized. This can be a viable approach to reconstruct extensive defects on the posterior trunk. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
USB noise reduction by nozzle and flap modifications
NASA Technical Reports Server (NTRS)
Hayden, R. E.
1976-01-01
The development of concepts for reducing upper surface blown flap noise at the source through flap modifications and special nozzles is reviewed. In particular, recent results obtained on the aerodynamic and acoustic performance of flaps with porous surfaces near the trailing edge and multi-slotted nozzles are reviewed. Considerable reduction (6-10 db) of the characteristic low frequency peak is shown. The aerodynamic performance is compared with conventional systems, and prospects for future improvements are discussed.
Pressure Distribution Over a Symmetrical Airfoil Section with Trailing Edge Flap
NASA Technical Reports Server (NTRS)
Jacobs, Eastman N; Pinkerton, Robert M
1931-01-01
Measurements were made to determine the distribution of pressure over one section of an R. A. F. 30 (symmetrical) airfoil with trailing edge flaps. In order to study the effect of scale measurements were made with air densities of approximately 1 and 20 atmospheres. Isometric diagrams of pressure distribution are given to show the effect of change in incidence, flap displacement, and scale upon the distribution. Plots of normal force coefficient versus angle of attack for different flap displacements are given to show the effect of a displaced flap. Plots are given of both the experimental and theoretical characteristic coefficients versus flap angle, in order to provide a comparison with the theory. It is concluded that for small flap displacements the agreement for the pitching and hinge moments is such that it warrants the use of the theoretical parameters. However, the agreement for the lift is not as good, particularly for the smaller flaps. In an appendix, an example is given of the calculation of the load and moments on an airfoil with hinged flap from these parameters.
Reconstruction of trochanteric pressure sores with pedicled anterolateral thigh myocutaneous flaps.
Wang, Chih-Hsin; Chen, Shih-Yi; Fu, Ju-Peng; Dai, Niann-Tzyy; Chen, Shao-Liang; Chen, Tim-Mo; Chen, Shyi-Gen
2011-05-01
To provide an alternative choice for covering trochanteric pressure sores, we report on a modified pedicle anterolateral thigh (ALT) myocutaneous flap based on the descending branch of the lateral circumflex femoral artery. From August 2007 to January 2010, 20 consecutive patients (10 men and 10 women) underwent 21 pedicled ALT myocutaneous flaps for reconstruction of trochanteric pressure sores. The flap was designed and elevated, resembling the ALT perforator flap including part of the vastus lateralis muscle but without skeletonisation of the perforators. The mean age of patients was 79.4 years (range: 46-103). The mean follow-up period was 13.9 months (range: 3-32). The flaps were 8-21 cm long and 5-11 cm wide. All flaps healed without major complications. All donor sites were closed primarily without skin grafting and showed good aesthetic results. No recurrence was observed. This modified design of pedicled ALT myocutaneous flap without skeletonisation of perforators is a reliable and easily harvested flap for reconstruction of trochanteric pressure sores with limited morbidity. Crown Copyright © 2010. Published by Elsevier Ltd. All rights reserved.
Zang, Mengqing; Yu, Shengji; Xu, Libin; Zhao, Zhenguo; Zhu, Shan; Ding, Qiang; Liu, Yuanbo
2015-06-01
Trunk defects following soft tissue sarcoma resection are usually managed by myocutaneous flaps or free flaps. However, harvesting muscle will cause functional morbidities and some trunk regions lack reliable recipient vessels. The intercostal arteries give off multiple perforators, which distribute widely over the trunk and can supply various pedicle flaps. Our purpose is to use various intercostal artery perforator propeller flaps for trunk oncologic reconstruction. Between November 2013 and July 2014, nine intercostal artery perforator propeller flaps were performed in seven patients to reconstruct the defects following sarcoma resection in different regions of the trunk, including the back, lumbar, chest, and abdomen. Two perforators from intercostal arteries were identified for each flap using Doppler ultrasound probe adjacent to the defect. The perforator with visible pulsation was chosen as the pedicle vessel. An elliptical flap was raised and rotated in a propeller fashion to repair the defects. There were one dorsal intercostal artery perforator flap, four dorsolateral intercostal artery perforator flaps, three lateral intercostal artery perforator flaps, and one anterior intercostal artery perforator flap. The mean skin paddle dimension was 9.38 cm in width (range 6-14 cm) and 21.22 cm in length (range 13-28 cm). All intercostal artery perforator flaps survived completely, except for marginal necrosis in one flap harvested close to the previous flap donor site. The intercostal artery perforator propeller flap provides various and valuable options in our reconstructive armamentarium for trunk oncologic reconstruction. To our knowledge, this is the first case series of using intercostal artery perforator propeller flaps for trunk oncologic reconstruction and clinical application of dorsolateral intercostal artery perforator flaps. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All
Ismail, H.; Elshobaky, A.
2016-01-01
Summary Anterior cervical contractures of the neck represent a great challenge for plastic and reconstructive surgeons. Necks can be reconstructed with a wide range of surgical techniques, including chimeric flaps, supercharged flap, pre-expanded flaps, “superthin” flaps and perforator flaps. The supraclavicular flap is easy to harvest without the need for free tissue transfer. It provides a relatively large flap for neck resurfacing with tissue very similar to that of the neck. Between January 2013 and March 2015, 20 patients suffering from postburn neck contracture underwent reconstruction with 20 unilateral supraclavicular artery perforator flaps. Nineteen patients had post-burn neck contractures (9 cases type Іc, 10 cases type Пc) while only one had post-burn granulation tissue in the neck. We harvested fifteen flaps from the right side and five from the left. Size of the reconstructed defect ranged from 23x10 to14x6, and flap size varied from 25/11 to 16/7cm. Period of follow up ranged from 27-2months (average 12.3). Nineteen flaps survived well (95% survival rate): only one was lost due to iatrogenic extensive dissection over the pedicle. Five cases showed distal superficial epidermolysis, and 2 cases showed 2 cm complete distal necrosis. All patients were managed conservatively. Our results coincide with other literature results confirming the efficacy and rich vascularity of this flap. In all cases with distal partial necrosis, flaps were 23 cm or more. We recommend that supraclavicular flaps of more than 22 cm in length are not harvested immediately and that flaps are expanded before harvesting. Expanding the supraclavicular flap increases its surface area and decreases donor site morbidity. PMID:28149252
Viscous investigation of a flapping foil propulsor
NASA Astrophysics Data System (ADS)
Posri, Attapol; Phoemsapthawee, Surasak; Thaweewat, Nonthipat
2018-01-01
Inspired by how fishes propel themselves, a flapping-foil device is invented as an alternative propulsion system for ships and boats. The performance of such propulsor has been formerly investigated using a potential flow code. The simulation results have shown that the device has high propulsive efficiency over a wide range of operation. However, the potential flow gives good results only when flow separation is not present. In case of high flapping frequency, the flow separation can occur over a short instant due to fluid viscosity and high angle of attack. This may cause a reduction of propulsive efficiency. A commercial CFD code based on Lattice Boltzmann Method, XFlow, is then employed in order to investigate the viscous effect over the propulsive performance of the flapping foil. The viscous results agree well with the potential flow results, confirming the high efficiency of the propulsor. As expected, viscous results show lower efficiency in high flapping frequency zone.
Perforator-based propeller flaps for leg reconstruction in pediatric patients.
Özalp, Burhan; Aydınol, Mustafa
2016-10-01
Perforator-based propeller flaps provide adequate soft tissue coverage for leg reconstruction. The aim of this study was to assess the versatility and reliability of the use of propeller flaps for leg reconstruction in pediatric patients. Seven male pediatric patients ranging in age from 2 to 13 years with a mean age of 6.7 underwent perforator-based propeller flap surgery over a four-year period. The defects resulted from burn injuries (n = 4) and traffic accidents (n = 3). The injuries were located on the ankles of four patients and on the knee, anterior lower tibia, and foot dorsum of the other three patients, respectively. The flap sizes ranged from 5 × 3 to 10 × 6 cm with a mean flap size of 7.6 × 4.3 cm. Flap harvesting time ranged from 38 to 56 m with a mean of 46 m. The rotation degree range of the flaps was from 90° to 180°. The propeller flaps were based on the posterior tibial artery (n = 4), anterior tibial artery (n = 2), and the descending branch of the lateral circumflex femoral artery (n = 1). All flaps survived completely without surgical complication; however, one patient developed disseminated intravascular coagulation syndrome two days post-surgery and died within four days. Perforator-based propeller flap reconstruction is a safe, reliable, and versatile method for lower extremities in pediatric patients; however, it requires meticulous surgical dissection and extreme patience during the surgical procedure. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Improving Pressure Ulcer Reconstruction: Our Protocol and the COP (Cone of Pressure) Flap
Edstrom, Lee; Szymanski, Karen; Schmidt, Scott; Bevivino, Jack; Zienowicz, Richard; Stark, Jennifer; Taylor, Helena O.; Podda, Silvio; Liu, Paul
2017-01-01
Background: Surgical treatment of pressure ulcers is challenging for high recurrence rates. Deepithelialized flaps have been used previously with the aim to eliminate shearing forces and the cone of pressure (COP) effect. The goal of this study is to adopt a standardized protocol and evaluate if 2 different flap techniques affect outcomes. Methods: The novel COP flap is illustrated. Twenty patients were prospectively treated with flap coverage over a 36-month period. According to the flap type, patients were assigned to 2 groups: group 1 with 11 patients treated with the COP flap and group 2 with 9 patients treated with conventional flap without anchoring technique. We adopted a standardized protocol of debridement, tissue cultures, and negative-pressure wound therapy. Rotation fasciocutaneous flaps were used for both groups and mean follow-up was 19 months. The COP flap is a large deepithelialized rotation flap inset with transcutaneous nonabsorbable bolster sutures. The 2 groups were comparable for demographics and ulcer location and size (P < 0.05). Five patients showed positive cultures and were treated with antibiotics and negative-pressure therapy before surgery. Results: Recurrence rates were 12% in the COP flap group and 60% in the conventional flap coverage group (P < 0.001). Results were compared at 16-month follow-up. Conclusions: The COP flap significantly reduces recurrences and eliminates shearing forces, suture ripping, and tension on superficial soft-tissue layers. The technique can be applied to both ischial and sacral pressure sores. The flap provides padding over bony prominence without jeopardizing flap vascularity. PMID:28458961
Free radial forearm adiposo-fascial flap for inferior maxillectomy defect reconstruction
Thankappan, Krishnakumar; Trivedi, Nirav P.; Sharma, Mohit; Kuriakose, Moni A.; Iyer, Subramania
2009-01-01
A free radial forearm fascial flap has been described for intraoral reconstruction. Adiposo-fascial flap harvesting involves few technical modifications from the conventional radial forearm fascio-cutaneous free flap harvesting. We report a case of inferior maxillectomy defect reconstruction in a 42-year-old male with a free radial forearm adiposo-fascial flap with good aesthetic and functional outcome with minimal primary and donor site morbidity. The technique of raising the flap and closing the donor site needs to be meticulous in order to achieve good cosmetic and functional outcome. PMID:19881028
50 CFR Figure 16 to Part 223 - Escape Opening and Flap Dimensions for the Double Cover Flap TED
Code of Federal Regulations, 2010 CFR
2010-10-01
... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false Escape Opening and Flap Dimensions for the Double Cover Flap TED 16 Figure 16 to Part 223 Wildlife and Fisheries NATIONAL MARINE FISHERIES SERVICE, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE MARINE MAMMALS THREATENED MARINE AND ANADROMOUS SPECIES Pt. 223, Fig. 1...
[Reconstruction of facial soft tissue defects with pedicled expanded flaps].
Yangqun, Li; Yong, Tang; Wen, Chen; Zhe, Yang; Muxin, Zhao; Lisi, Xu; Chunmei, Hu; Yuanyuan, Liu; Ning, Ma; Jun, Feng; Weixin, Wang
2014-09-01
To investigate the application of pedicled expanded flaps for the reconstruction of facial soft tissue defects. The expanded skin flaps, pedicled with orbicularis oculi muscle, submental artery, the branch of facial artery, superficial temporal artery, interior upper arm artery, had similar texture and color as facial soft tissue. The pedicled expanded flaps have repaired the facial soft tissue defects. Between Jan. 2003 to Dec. 2013, 157 cases with facial soft tissue defects were reconstructed by pedicled expanded flaps. Epidermal necrosis happened at the distal end of 8 expanded flaps, pedicled with interior upper arm artery(4 cases), orbicularis oculi muscle(3 cases) and submental artery(1 case), which healed spontaneously after dressing. All the other flaps survived completely with similar color and inconspicuous scar. 112 cases were followed up for 8 months to 8 years. Satisfactory results were achieved in 75 cases. 37 cases with hypertrophic scar at incisions need secondary operation. Island pedicled expanded flap with similar texture and color as facial soft tissue is suitable for facial soft tissue defects. The facial extra-incision and large dog-ear deformity could be avoided.
Knackstedt, Thomas; Lee, Kachiu; Jellinek, Nathaniel J
2018-05-22
Bilobed and trilobed transposition flaps are versatile random pattern transposition flaps which reliably restore nasal symmetry, topography, light reflex, contour and are frequently used in cutaneous nasal reconstructive surgery. We wish to compare the characteristics of bilobed and trilobed flaps in cutaneous reconstructive surgery and to identify scenarios for their differential use. A retrospective chart review over 7 years of consecutive patients reconstructed with a bilobed or trilobed flap after Mohs micrographic surgery was performed. Statistical analysis of patient and surgery characteristics, anatomic distribution, postprocedural events and need for revisions after both flap types was conducted. One hundred eleven patients with bilobed flaps and 74 patients with trilobed flaps were identified. Bilobed flaps are significantly more frequently used on the inferior nasal dorsum and on the sidewall whereas trilobed flaps are significantly more frequently used on the nasal tip and infratip. No significant difference in postprocedural events (complications, erythema, trapdoor, etc) was noted between the two flap types. Bilobed and trilobed transposition flaps are versatile repairs for nasal reconstruction. Trilobed flaps may be used to repair defects in a more distal nasal location than bilobed flaps. Regardless of flap type, complications are rare.
Moro, Alessandro; Saponaro, Gianmarco; Doneddu, Piero; Cervelli, Daniele; Pelo, Sandro; Gasparini, Giulio; Garagiola, Umberto; D'Amato, Giuseppe; Todaro, Mattia
2018-05-15
In 1992, Pribaz described the facial artery musculomucosal flap (FAMM), an axial musculomucosal flap based on the facial artery. The FAMM flap, a modification of the nasolabial and buccal mucosal flaps, is widely used in the reconstruction of defects in the oral cavity. Many modifications of this flap have been described in the literature. Here we aimed to explore the use of an arterialized tunnelized FAMM island flap (a-FAMMIF) for the reconstruction tongue defects after tumor resection. From January 2015 to December 2016, five cases of tongue cancer were selected for the use of arterialized FAMMIF flap to reconstruct defects after tumor resection. Reconstruction was successful in all cases, except one case of total flap necrosis; partial necrosis of the flap occurred in two patients, which were solved with medications. The authors consider the a-FAMMIF an unreliable flap in the reconstruction of tongue defects.The authors recommend avoiding tunneling and island modification when the vein is not included in the pedicle.
Near-Infrared Irradiation Increases Length of Axial Pattern Flap Survival in Rats.
Yasunaga, Yoshichika; Matsuo, Kiyoshi; Tanaka, Yohei; Yuzuriha, Shunsuke
2017-01-01
Objective: We previously reported that near-infrared irradiation nonthermally induces long-lasting vasodilation of the subdermal plexus by causing apoptosis of vascular smooth muscle cells. To clarify the possible application of near-infrared irradiation to prevent skin flap necrosis, we evaluated the length of axial pattern flap survival in rats by near-infrared irradiation. Methods: A bilaterally symmetric island skin flap was elevated under the panniculus carnosus on the rat dorsum. Half of the flap was subjected to near-infrared irradiation just before flap elevation with a device that simulates solar radiation, which has a specialized contact cooling apparatus to avoid thermal effects. The length of flap survival of the near-infrared irradiated side was measured 7 days after flap elevation and compared with the nonirradiated side. Results: The irradiated side showed elongation of flap survival compared with the nonirradiated side (73.3 ± 11.7 mm vs 67.3 ± 14.9 mm, respectively, P = .03). Conclusions: Near-infrared irradiation increases the survival length of axial pattern flaps in rats.
Propeller Flaps: A Review of Indications, Technique, and Results
D'Arpa, Salvatore; Toia, Francesca; Pirrello, Roberto; Moschella, Francesco; Cordova, Adriana
2014-01-01
In the last years, propeller flaps have become an appealing option for coverage of a large range of defects. Besides having a more reliable vascular pedicle than traditional flap, propeller flaps allow for great freedom in design and for wide mobilization that extend the possibility of reconstructing difficult wounds with local tissues and minimal donor-site morbidity. They also allow one-stage reconstruction of defects that usually require multiple procedures. Harvesting of a propeller flap requires accurate patient selection, preoperative planning, and dissection technique. Complication rate can be kept low, provided that potential problems are prevented, promptly recognized, and adequately treated. This paper reviews current knowledge on propeller flaps. Definition, classification, and indications in the different body regions are discussed based on a review of the literature and on the authors' experience. Details about surgical technique are provided, together with tips to avoid and manage complications. PMID:24971367
Optimization of the Flapping Wing Systems for Micro Air Vehicle
2010-09-01
as 87%, under specific combinations of the flapping kinematics by water tunnel experiments [5]. Pesavento and Wang found that optimized flapping wing...41-72. [6] Pesavento , U., and Wang Z. J., “Flapping Wing Flight Can Save Aerodynamic Power Compared to Steady Flight,” Physical Review Letters
The plane problem of the flapping wing
NASA Technical Reports Server (NTRS)
Birnbaum, Walter
1954-01-01
In connection with an earlier report on the lifting vortex sheet which forms the basis of the following investigations this will show how the methods developed there are also suitable for dealing with the air forces for a wing with a circulation variable with time. The theory of a propulsive wing flapping up and down periodically in the manner of a bird's wing is developed. This study shows how the lift and its moment result as a function of the flapping motion, what thrust is attainable, and how high is the degree of efficiency of this flapping propulsion unit if the air friction is disregarded.
Vulva reconstruction after pelvic exenteration, using a unique combination of two flaps
van Bommel, Annelotte C M; Schreuder, Henk W R; Schellekens, Pascal P A
2011-01-01
A 64-year-old woman with recurrence of carcinoma of the vulva in an irradiated area received an en-bloc total pelvic exenteration. Reconstruction of the pelvic defect was performed with an anterolateral thigh (ALT) flap and a rectus abdominis muscle (RAM) flap (PM/RAM). This combination of flaps is unique, with excellent results. In a large defect, often irradiated in advance, well-vascularised tissue should be placed. Multiple flaps can be used to reconstruct these large pelvic defects, each with their own advantages and disadvantages. The combination of flaps used in this case uses the good properties of both flaps: the reliable and well-vascularised PM/RAM in combination with the ALT flap to provide much bulk in extreme large defects. PMID:22692483
Fourman, Mitchell Stephen; Gersch, Robert P; Phillips, Brett T; Nasser, Ahmed; Rivara, Andrew; Verma, Richa; Dagum, Alexander B; Rosengart, Todd K; Bui, Duc T
2015-07-01
The McFarlane rat ischemic dorsal skin flap model has been commonly used for clinical vector studies, as well as the testing of noninvasive diagnostics. However, variability of this model secondary to flap contact with the wound bed has led many to question its validity. Here we present a novel modification to the McFarlane skin flap using sterile silicone. We also use this model to test the prognostic efficacy of laser-assisted indocyanine green (ICG) angiography and laser Doppler imaging (LDI). A 3 × 9-cm dorsal skin flap with a cranially based pedicle was created, centered 1 cm distal to the scapulae. The flap was undermined, and in one of the 2 groups, a sterile silicone sheet was placed onto the wound bed. All flaps were then reapproximated with sutures 1-cm intervals. Clinical assessment and perfusion imaging was performed immediately postoperative, and at 24, 48, and 72 hours postsurgery. Postoperative day 7 clinical assessment was obtained before euthanasia. A comparative study using silicone blocked versus unblocked models (n = 6 per group) showed that, clinically, both models had equivalent flap survival [8.5 (0.913) vs 9.5 (1.01) cm]. However, a statistically significant increase in perfusion in the mid-third of unblocked models was observed on POD3 [20.28% (2.7%) vs blocked 13.45% (2.5%), P < 0.05], with a similar increase in the distal third on POD7 [18.73% (2.064%) vs 10.91% (4.19%), P < 0.05]. A prognostic study comparing LDI and ICG angiography prediction of POD7 survival at early time points (n = 10) found that LDI underpredicted flap survival at early time points [84.2% (12.03%) on POD0, 87.35% (16.11%) on POD1]. In contrast, ICG was more proficient [100.1% (10.1%) on POD0]. We present a modification of the McFarlane skin flap model that results in similar clinical results, but with a noted reduction in perfusion inconsistencies noted in unblocked models. The ICG angiography is superior to LDI in predicting POD7 flap necrosis within the first 48
Facial artery musculomucosal flap for reconstruction of skull base defects: a cadaveric study.
Xie, Liyue; Lavigne, François; Rahal, Akram; Moubayed, Sami Pierre; Ayad, Tareck
2013-08-01
Failure in skull base defects reconstruction following tumor resection can have serious consequences such as ascending meningitis and pneumocephaly. The nasoseptal flap showed a very low incidence of cerebrospinal fluid leak but is not always available. The superiorly pedicled facial artery musculomucosal (FAMM) flap has been successfully used for reconstruction of head and neck defects. Our objective is to show that the FAMM flap can be used as a new alternative in skull base reconstruction. Cadaveric study. Feasibility. Thirteen specimens underwent bilateral FAMM flap dissection. Two new modifications of the traditional FAMM flap have been developed. Feasibility in FAMM flap transfer to the skull base was investigated through endoscopic skull base dissection and maxillectomy in four specimens. Measurements were recorded for each harvested flap. The mean surface area of the modified FAMM flap efficient for reconstruction was 15.90 cm(2) . The flaps easily covered the simulated defects of the frontal sinus and the fovea ethmoidalis areas. Modifications of the traditional FAMM flap were necessary for a tension-free coverage of the planum sphenoidale and sella turcica. The FAMM flap holds high potential as a new alternative vascular flap in skull base reconstruction. However, it has not been used in patients yet and should be considered only when other options are not available. New modifications developed in this article can elongate the traditional FAMM flap, potentially contributing to a tighter seal of the skull base defect than FAMM flap alone. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.
Biochemical and Cellular Assessment of Acetabular Chondral Flaps Identified During Hip Arthroscopy.
Hariri, Sanaz; Truntzer, Jeremy; Smith, Robert Lane; Safran, Marc R
2015-06-01
To analyze chondral flaps debrided during hip arthroscopy to determine their biochemical and cellular composition. Thirty-one full-thickness acetabular chondral flaps were collected during hip arthroscopy. Biochemical analysis was undertaken in 21 flaps from 20 patients, and cellular viability was determined in 10 flaps from 10 patients. Biochemical analysis included concentrations of (1) DNA (an indicator of chondrocyte content), (2) hydroxyproline (an indicator of collagen content), and (3) glycosaminoglycan (an indicator of chondrocyte biosynthesis). Higher values for these parameters indicated more healthy tissue. The flaps were examined to determine the percentage of viable chondrocytes. The percentage of acetabular chondral flap specimens that had concentrations within 1 SD of the mean values reported in previous normal cartilage studies was 38% for DNA, 0% for glycosaminoglycan, and 43% for hydroxyproline. The average cellular viability of our acetabular chondral flap specimens was 39% (SD, 14%). Only 2 of the 10 specimens had more than half the cells still viable. There was no correlation between (1) the gross examination of the joint or knowledge of the patient's demographic characteristics and symptoms and (2) biochemical properties and cell viability of the flap, with one exception: a degenerative appearance of the surrounding cartilage correlated with a higher hydroxyproline concentration. Although full-thickness acetabular chondral flaps can appear normal grossly, the biochemical properties and percentage of live chondrocytes in full-thickness chondral flaps encountered in hip arthroscopy show that this tissue is not normal. There has been recent interest in repairing chondral flaps encountered during hip arthroscopy. These data suggest that acetabular chondral flaps are not biochemically and cellularly normal. Although these flaps may still be valuable mechanically and/or as a scaffold in some conductive or inductive capacity, further study is
LASIK flap buttonhole treated immediately by PRK with mitomycin C.
Kymionis, George D; Portaliou, Dimitra M; Karavitaki, Alexandra E; Krasia, Maria S; Kontadakis, Georgios A; Stratos, Aimilianos; Yoo, Sonia H
2010-03-01
To describe the visual outcomes of three patients who had LASIK flap buttonhole and were treated immediately with photorefractive keratectomy (PRK) and topical mitomycin C (MMC) 0.02%. Three patients underwent bilateral LASIK with the SCHWIND Carriazo-Pendula 90 microm head microkeratome. In all three cases, a buttonhole flap occurred in the left eye. The flap was repositioned and phototherapeutic keratectomy for 50 microm was used for epithelial removal while immediate PRK with MMC was performed to treat the buttonhole flap. Three months after the procedure, uncorrected distance visual acuity and corrected distance visual acuity were 20/20 with regular topographic findings. Using PRK with MCC immediately after the occurrence of the LASIK flap buttonhole may be an effective treatment.
Study of Flapping Flight Using Discrete Vortex Method Based Simulations
NASA Astrophysics Data System (ADS)
Devranjan, S.; Jalikop, Shreyas V.; Sreenivas, K. R.
2013-12-01
In recent times, research in the area of flapping flight has attracted renewed interest with an endeavor to use this mechanism in Micro Air vehicles (MAVs). For a sustained and high-endurance flight, having larger payload carrying capacity we need to identify a simple and efficient flapping-kinematics. In this paper, we have used flow visualizations and Discrete Vortex Method (DVM) based simulations for the study of flapping flight. Our results highlight that simple flapping kinematics with down-stroke period (tD) shorter than the upstroke period (tU) would produce a sustained lift. We have identified optimal asymmetry ratio (Ar = tD/tU), for which flapping-wings will produce maximum lift and find that introducing optimal wing flexibility will further enhances the lift.
NASA Technical Reports Server (NTRS)
Aoyagi, Kiyoshi; Hickey, David H.
1959-01-01
Previous investigations have shown that increased blowing at the hinge-line radius of a plain flap will give flap lift increases above that realized with boundary-layer control. Other experiments and theory have shown that blowing from a wing trailing edge, through the jet flap effect, produced lift increases. The present investigation was made to determine whether blowing simultaneously at the hinge-line radius and trailing edge would be more effective than blowing separately at either location. The tests were made at a Reynolds number of 4.5 x 10(exp 6) with a 35 deg sweptback-wing airplane. For this report, only the lift data are presented. Of the three flap blowing arrangements tested, blowing distributed between the trailing edge and the hinge-line radius of a plain flap was found to be superior to blowing at either location separately at the plain flap deflections of interest. Comparison of estimated and experimental jet flap effectiveness was fair.
NASA Technical Reports Server (NTRS)
Mckinzie, D. J., Jr.; Burns, R. J.; Wagner, J. M.
1976-01-01
Noise data were obtained with a large-scale cold-flow model of a two-flap, under-the-wing, externally blown flap proposed for use on future STOL aircraft. The noise suppression effectiveness of locating a slot conical nozzle at the trailing edge of the second flap and of applying partial covers to the slots between the wing and flaps was evaluated. Overall-sound-pressure-level reductions of 5 db occurred below the wing in the flyover plane. Existing models of several noise sources were applied to the test results. The resulting analytical relation compares favorably with the test data. The noise source mechanisms were analyzed and are discussed.
Hwang, Euna; Kim, Young Soo; Chung, Seum
2014-06-01
Before visiting a plastic surgeon, some microtia patients may undergo canaloplasty for hearing improvement. In such cases, scarred tissues and the reconstructed external auditory canal in the postauricular area may cause a significant limitation in using the posterior auricular skin flap for ear reconstruction. In this article, we present a new method for auricular reconstruction in microtia patients with previous canaloplasty. By dividing a postauricular skin flap into an upper scalp extended skin flap and a lower mastoid extended skin flap at the level of a reconstructed external auditory canal, the entire anterior surface of the auricular framework can be covered with the two extended postauricular skin flaps. The reconstructed ear shows good color match and texture, with the entire anterior surface of the reconstructed ear being resurfaced with the skin flaps. Clinical question/level of evidence; therapeutic level IV. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Preoperative color Doppler assessment in planning of gluteal perforator flaps.
Isken, Tonguc; Alagoz, M Sahin; Onyedi, Murat; Izmirli, Hakki; Isil, Eda; Yurtseven, Nagehan
2009-02-01
Gluteal artery perforator flaps have gained popularity due to reliability, preservation of the muscle, versatility in flap design without restricting other flap options, and low donor-site morbidity in ambulatory patients and possibility of enabling future reconstruction in paraplegic patients. But the inconstant anatomy of the vascular plexus around the gluteal muscle makes it hard to predict how many perforators are present, what their volume of blood flow and size are, where they exit the overlying fascia, and what their course through the muscle will be. Without any prior investigations, the reconstructive surgeon could be surprised intraoperatively by previous surgical damage, scar formation, or anatomic variants.For these reasons, to confirm the presence and the location of gluteal perforators preoperatively we have used color Doppler ultrasonography. With the help of the color Doppler ultrasonography 26 patients, 21 men and 5 women, were operated between the years 2002 and 2007. The mean age of patients was 47.7 (age range: 7-77 years). All perforator vessels were marked preoperatively around the defect locations. The perforator based flap that will allow primary closure of the donor site and the defect without tension was planned choosing the perforator that showed the largest flow in color Doppler ultrasonography proximally. Perforators were found in the sites identified with color Doppler ultrasonography in all other flaps. In our study, 94.4% flap viability was ensured in 36 perforator-based gluteal area flaps. Mean flap elevation time was 31.9 minutes. We found that locating the perforators preoperatively helps to shorten the operation time without compromising a reliable viability of the perforator flaps, thus enabling the surgeon easier treatment of pressure sores.
Design and construction of an airfoil with controlled flap
NASA Astrophysics Data System (ADS)
Amin, Md. Ruhul; Rahman, S. M. Mahbobur; Mashud, Mohammad; Rabbi, Md. Fazle
2017-06-01
For modern aircrafts maneuvering control and reduction of power loss is a matter of great concern in Aerodynamics. Separation of airflow over the wings of aircraft at high angle of attack or at other situations is a hindrance to proper maneuvering control. As flow separation increases drag force on the aircraft, it consumes excess power. For these reasons much effort and research has gone into the design of aerodynamic surfaces which delay flow separation and keep the local flow attached for as long as possible. One of the simple and cost-effective way is to use a hinged flap on the wing of the aircraft, which lifts and self-adjusts to a position dependent on the aerodynamic forces and flap weight due to reversed flow at increasing angle of attack. There is a limitation of this kind of process. At very high angles of attack, the reversed flow would cause the flap to tip forwards entirely and the effect of the flap would vanish. For recovering this limitation an idea of controlling the movement or rotation of the flap has been proposed in this paper. A light surface was selected as a flap and was coupled to the shaft of a servo motor, which was placed on a model airfoil. For controlling the angle of rotation of the motor as well as the flap arbitrarily, an electronic circuit comprising necessary components was designed and applied to the servo motor successfully.
V-Y and rotation flap for reconstruction of the epicanthal fold.
Shin, Yong Ho; Hwang, Pil Joong; Hwang, Kun
2012-07-01
Epicanthoplasty is commonly performed on Asian eyelids. Consequently, overcorrection may appear. The aim of this study was to introduce a method of reconstructing the epicanthal fold and to apply this method to the patients. A V flap with an extension (eagle beak shaped) was designed on the medial canthal area. The upper incision line started near the medial end of the double-fold line, and it followed its curvature inferomedially. For the lower incision, starting at the tip (medial end) of the flap, a curvilinear incision was designed first diagonally and then horizontally along the lower blepharoplasty line. The V flap was elevated as thin as possible. Then, the upper flap was deeply undermined to make it thick. The lower flap was made a little thinner than the upper flap. Then, the upper and lower flaps were approximated to form the anteromedial surface of the epicanthal fold in a fashion sufficient to cover the red caruncle. The V flap was rotated inferolaterally over the caruncle. The tip of the V flap was sutured to the medial one-third point of the lower margin. The inferior border of the V flap and the residual lower margin were approximated. Thereafter, the posterolateral surface of the epicanthal fold was made. From 1999 to 2011, 246 patients were operated on using this method. Among them, 62 patients were followed up. The mean intercanthal distance was increased from 31.7 to 33.8 mm postoperatively. Among the 246 patients operated on, reoperation was performed for 6 patients. Among the 6 patients reoperated on, 3 cases were due to epicanthus inversus, 1 case was due to insufficient reconstruction, 1 case was due to making an infold, and 1 case was due to reopening the epicanthal fold.This V-Y and rotation flap can be a useful method for reconstruction of the epicanthal fold.
Bi, Xiaoping; Fan, Xianqun; Zhou, Huifang; Shi, Wodong; Xiao, Caiwen; Lin, Min; Li, Zhenkang
2011-05-01
Retinoblastoma is a common malignant intraocular tumor in childhood, and most patients require enucleation or exenteration even with irradiation. Severe anophthalmic orbits and atresic eye sockets are not rare. We conducted a retrospective study to evaluate the results of surgical management of reconstruction of severe anophthalmic orbits and atresic eye sockets with vascular anastomosed free dorsalis pedis flap transplantation. There were 5 patients (5 eyes) who underwent reconstructive surgery of severe anophthalmic orbits and atresic eye sockets after enucleation and irradiation of retinoblastoma in our hospital during the 3 years. All patients had enucleation and irradiation immediately after the retinoblastoma was diagnosed and had never worn artificial eyes because of the atresic eye sockets. Vascular anastomosed free dorsalis pedis flaps, whose dimensions were typically 6.5 × 5.5 cm(2), were transplanted to reconstruct the severe anophthalmic orbits and atresic eye sockets. The donor sites were covered by free abdominal skin flaps. All the vascular anastomosed free dorsalis pedis flaps were valid after more than 6 months of follow-up. And then all the 5 patients underwent secondary autogenous dermal fat implantation to augment the supraorbital area depression. After the 2-stage reconstruction surgery, the dimensions of the eye sockets were adequate, and all patients were able to wear their prosthesis and had a satisfactory cosmetic result. Implantation of alloplastic materials is not recommended because of insufficient blood supply of the irradiated orbital area.
In situ monitoring of surgical flap viability using THz imaging (Conference Presentation)
NASA Astrophysics Data System (ADS)
Bajwa, Neha; Sung, Shijun; Grundfest, Warren; Taylor, Zachary
2016-03-01
This paper explores the utility of reflective THz imaging to assess the viability of surgical flaps. Flap surgery is a technique where tissue is harvested from a donor site and moved to a recipient while keeping the blood supply intact. This technique is common in head and neck tumor resection surgery where the reconstruction of complex and sensitive anatomic structures is routine following the resection of large and/or invasive tumors. Successful flap surgery results in tissue that is sufficiently perfused with both blood and extracellular water. If insufficient fluid levels are maintained, the flap tissue becomes necrotic and must be excised immediately to prevent infection developing and spreading to the surrounding areas. The goal of this work is to investigate the hydration of surgical flaps and correlate image features to successful graft outcomes. Advancement flaps were created on the abdomens of rat models. One rat model was labeled control and care was taken to ensure a successful flap outcome. The flap on the second rat was compromised with restricted blood flow and allowed to fail. The flaps of both rats were imaged once a day over the course of a week at which point the compromised flap had begun to show signs of necrosis. Significant differences in tissue water content were observed between rats over the experimental period. The results suggest that THz imaging may enable early assessment of flap viability.
Pharmacologic manipulation of the microcirculation in cutaneous and myocutaneous flaps in pigs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pang, C.Y.; Neligan, P.C.; Nakatsuka, T.
1985-04-01
The vascular effects of isoxsuprine, diazoxide, and isoproterenol were studied in arterial buttock flaps and latissimus dorsi myocutaneous flaps in pigs. Capillary blood flow to the skin and muscles of these flaps was measured by the radioactive microsphere (15-mu diameter) technique 6 hours postoperatively under pentobarbital anesthesia. It was observed that isoproterenol, a beta-adrenergic receptor agonist, was not effective in augmentation of skin blood flow in the arterial buttock flaps. However, isoproterenol significantly increased capillary blood flow to the arterialized portion of latissimus dorsi myocutaneous flaps compared with controls. Isoxsuprine and diazoxide (vascular smooth muscle relaxants) significantly (p less thanmore » 0.05) increased total capillary blood flow to the skin of arterial buttock flaps and to the skin and muscles of the latissimus dorsi myocutaneous flaps. However, the increase in capillary blood flow occurred mainly in the arterialized portion of these flaps. The capillary blood flow, which was supplied by the small arteries in the distal portion of the arterial buttock and latissimus dorsi flaps, was not increased by treatment with isoxsuprine or diazoxide. Therefore, there was also no increase in the maximum distance of capillary blood flow from the pedicle to the distal end of the flaps. These observations led the authors to hypothesize that different sizes (diameters) of arteries in the skin and muscle have different reactivity (or sensitivity) to vasodilatory drugs. In the present experiment, the large dominant artery of the arterial buttock and latissimus dorsi flaps responded to isoxsuprine or diazoxide (vascular smooth-muscle relaxants), resulting in an increase in blood supply to the capillaries in the proximal portion of the flaps.« less
Surgeon-Based 3D Printing for Microvascular Bone Flaps.
Taylor, Erin M; Iorio, Matthew L
2017-07-01
Background Three-dimensional (3D) printing has developed as a revolutionary technology with the capacity to design accurate physical models in preoperative planning. We present our experience in surgeon-based design of 3D models, using home 3D software and printing technology for use as an adjunct in vascularized bone transfer. Methods Home 3D printing techniques were used in the design and execution of vascularized bone flap transfers to the upper extremity. Open source imaging software was used to convert preoperative computed tomography scans and create 3D models. These were printed in the surgeon's office as 3D models for the planned reconstruction. Vascularized bone flaps were designed intraoperatively based on the 3D printed models. Results Three-dimensional models were created for intraoperative use in vascularized bone flaps, including (1) medial femoral trochlea (MFT) flap for scaphoid avascular necrosis and nonunion, (2) MFT flap for lunate avascular necrosis and nonunion, (3) medial femoral condyle (MFC) flap for wrist arthrodesis, and (4) free fibula osteocutaneous flap for distal radius septic nonunion. Templates based on the 3D models allowed for the precise and rapid contouring of well-vascularized bone flaps in situ, prior to ligating the donor pedicle. Conclusions Surgeon-based 3D printing is a feasible, innovative technology that allows for the precise and rapid contouring of models that can be created in various configurations for pre- and intraoperative planning. The technology is easy to use, convenient, and highly economical as compared with traditional send-out manufacturing. Surgeon-based 3D printing is a useful adjunct in vascularized bone transfer. Level of Evidence Level IV. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Vortex shedding noise of a cylinder with hairy flaps
NASA Astrophysics Data System (ADS)
Kamps, Laura; Geyer, Thomas F.; Sarradj, Ennes; Brücker, Christoph
2017-02-01
This study describes the modification of acoustic noise emitted from cylinders in a stationary subsonic flow for a cylinder equipped with flexible hairy flaps at the aft part as a passive way to manipulate the flow and acoustics. The study was motivated by the results from previous water tunnel measurements, which demonstrated that hairy flaps can modify the shedding cycle behind the cylinder and can reduce the wake deficit. In the present study, wind tunnel experiments were conducted on such a modified cylinder and the results were compared to the reference case of a plain cylinder. The acoustic spectrum was measured using two microphones while simultaneously recording the flap motion. To further examine the flow structures in the downstream vicinity of the cylinder, constant temperature anemometry measurements as well as flow visualizations were also performed. The results show that, above a certain Reynolds number, the hairy flaps lead to a jump in the vortex shedding frequency. This phenomenon is similarly observed in the water flow experiments as a jump in the non-dimensional Strouhal number that is related to the change of the shedding cycle. This jump appears to be coupled to a resonant excitation of the flaps. The specific Reynolds number at which the jump occurs is higher in the present case, which is attributed to the lower added mass in air as compared with the one in water. The flow visualizations confirmed that such action of the flaps lead to a more slender elongated shape of the time-averaged separation bubble. In addition, the hairy flaps induce a noticeable reduction of the tonal noise as well as broadband noise as long as the flaps do not touch each other.
[Modified pectoralis major myocutaneous flap in reconstruction of head and neck defects].
Chen, Jie; Huang, Wenxiao; Li, Zan; Zhou, Xiao; Yu, Jianjun; Bao, Ronghua; Zhang, Hailin; Ling, Hang
2015-05-01
To report the experience of use of modified pectoralis major myocutaneous (PMMC) flaps in reconstruction of head and neck postoperative defects. A total of 107 patients who underwent head and neck defect reconstruction using modified PMMC flaps after tumor rescetion between Jan 2008 and Dec 2013 were analyzed retrospectively. The success rate of reconstruction with modified PMMC flaps was 94.4% (101/107). Five patients had partial flap necrosis and their wounds healed with dressing change. One patient (0.9%) had total flap necrosis, followed by the second reconstruction using contralateral PMMC flap. The modified falcate PMMC flap can obtain optimum quantity of the skin in the chest and decreasing the closing tension of the donnor site in favor of wound healing. The pedicle without muscle will not only maintain the partial function of the pectoralis major, but also help to avoid pressing the vascular pedicle within the subclavian tunnel. The muscular element the pedicled muscles of the PMMC flap can increase the ability of the flap to resist infection, which can use for covering an exposed carotid artery and improving the neck fibrosis of irradiated patients.
Unit Advancement Flap for Lower Lip Reconstruction.
Ogino, Akihiro; Onishi, Kiyoshi; Okada, Emi; Nakamichi, Miho
2018-05-01
Lower lip reconstruction requires consideration of esthetic and functional outcome in selecting a surgical procedure, and reconstruction with local tissue is useful. The authors reconstructed full-thickness defects with a unit advancement flap. Reconstruction was performed using this method in 4 patients with lower lip squamous cell carcinoma in whom tumor resection with preservation of the mouth angle was possible. The lower lip resection width was 30 to 45 mm, accounting for 50% to 68% of the entire width of the lower lip. The flap was prepared by lateral extension from above the mental unit and matched with the potential wrinkle line of the lower lip in order to design a unit morphology surrounded by the anterior margin of the depressor labii inferioris muscle. It was elevated as a full-thickness flap composed of the orbicularis oris muscle, skin, and mucosa of the residual lower lip from the bilateral sides, and advanced to the defect. Flap transfer was adjusted by small triangular resection of the skin on the lateral side of the mental unit. The postoperative scar was inconspicuous in all patients and there was no impairment of the mouth opening-closing or articulation functions. This was a relatively simple surgical procedure. A blood supply of the flap was stable, and continuity of the orbicularis oris muscle was reconstructed by transferred the residual lower lip advancement flap from the bilateral sides. The postoperative mouth opening-closing function was sufficient, and dentures could be placed from an early phase in elderly patients. The postoperative scar was consistent with the lip unit morphology, being esthetically superior. This procedure may be applicable for reconstruction of defects approximately 1/3 to 2/3 the width of the lower lip where the mouth angle is preserved.
Pedicled unipolar latissimus dorsi flap for reconstruction of finger extensor *
Takahashi, Mitsuhiko; Kasai, Tokio; Hibino, Naohito; Ishii, Seiji; Mitsuhashi, Tadashi
2017-01-01
Abstract We describe the use of a pedicled unipolar latissimus dorsi flap to restore finger extension. The patient had large defects in the radial nerve and extensor musculature. A long-tailed, 50-cm-long flap was prepared, which enabled the end of the flap to be sutured to the extensor digitorum. PMID:28470032
He, Yue; Zhu, Han Guang; Zhang, Zhi Yuan; He, Jie; Sader, Robert
2009-12-01
A total maxillectomy always causes composite defects of maxilla, zygomatic bone, orbital floor or rim, and palatal and nasal mucosa lining. This leads to significant functional and cosmetic consequences after ablative surgery. The purpose of this clinical study was to preliminarily 3-dimensionally reconstruct the defect of total maxillectomy with sufficient bone support and soft tissue lining. Three-dimensional model simulation technique and free fibula osteomyocutaneous flap flow-through from radial forearm flap were used to reconstruct a total maxillectomy defect for a 21-year-old female patient. Preoperatively, the 3-dimensional (3D) simulated resin models of skeleton and fibula were used to design the osteotomies and bone segment replacement. At surgery, a 22-cm-length free fibula was divided into 4 segments to make 1 maxilla skeletal framework in the schedule of the preoperative model surgical planning with a radial forearm flap flow-through for the free fibula flap with skin paddle to repair the palatal and nasal region. Free fibula and radial forearm flap were alive, and the patient was satisfied with the results both esthetically and functionally after dental rehabilitation which was carried out 6 months after surgery. This preliminarily clinical study and case demonstrated that: the fibula osteomyocutaneous flap is an ideal donor site in 3D total maxillectomy defect reconstruction, because of its thickness, length, and bone uniformity which makes ideal support for dental rehabilitation; the flow-through forearm radial flap not only serves as the vascular bridge to midface reconstruction, but also provides sufficient soft tissue cover for the intraoral defect; and the 3D model simulation and preoperative surgical planning are effective methods to refine reconstruction surgery, shorten the surgical time, and predict the outcome after operation.
Effect of topically applied minoxidil on the survival of rat dorsal skin flap.
Gümüş, Nazım; Odemiş, Yusuf; Yılmaz, Sarper; Tuncer, Ersin
2012-12-01
Flap necrosis still is a challenging problem in reconstructive surgery that results in irreversible tissue loss. This study evaluated the effect of topically applied minoxidil on angiogenesis and survival of a caudally based dorsal rat skin flap. For this study, 24 male Wistar rats were randomly divided into three groups of eight each. A caudally based dorsal skin flap with the dimensions of 9 × 3 cm was raised. After elevation of the flaps, they were sutured back into their initial positions. In group 1 (control group), 1 ml of isotonic saline was applied topically to the flaps of all the animals for 14 days. In group 2, minoxidil solution was spread uniformly over the flap surface for 7 days after the flap elevation. In group 3, minoxidil solution was applied topically to the flap surface during a 14-day period. On day 7 after the flap elevation, the rats were killed. The average area of flap survival was determined for each rat. Subdermal vascular architecture and angiogenesis were evaluated under a light microscope after two full-thickness skin biopsy specimens had been obtained from the midline of the flaps. The lowest flap survival rate was observed in group 1, and no difference was observed between groups 1 and 2. Compared with groups 1 and 2, group 3 had a significantly increased percentage of flap survival (P < 0.05). Intense and moderate angiogenesis also was observed respectively at the proximal and distal areas of the flaps in group 3. The results of this experiment seem to show that the early effect of minoxidil is vasodilation and that prolonged use before flap elevation leads to angiogenesis, increasing flap viability. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
The Temporalis Muscle Flap for Palate Reconstruction: Case Series and Review of the Literature
Brennan, Tara; Tham, Tristan M.; Costantino, Peter
2017-01-01
Introduction The temporalis myofascial (TM) is an important reconstructive flap in palate reconstruction. Past studies have shown the temporalis myofascial flap to be safe as well as effective. Free flap reconstruction of palate defects is also a popular method used by contemporary surgeons. We aim to reaffirm the temporalis myofascial flap as a viable alternative to free flaps for palate reconstruction. Objective We report our results using the temporalis flap for palate reconstruction in one of the largest case series reported. Our literature review is the first to describe complication rates of palate reconstruction using the TM flap. Methods Retrospective chart review and review of the literature. Results Fifteen patients underwent palate reconstruction with the TM flap. There were no cases of facial nerve injury. Five (33%) of these patients underwent secondary cranioplasty to address temporal hollowing after the TM flap. Three out of fifteen (20%) had flap related complications. Fourteen (93%) of the palate defects were successfully reconstructed, with the remaining case pending a secondary procedure to close the defect. Ultimately, all of the flaps (100%) survived. Conclusion The TM flap is a viable method of palate defect closure with a high defect closure rate and flap survival rate. TM flaps are versatile in repairing palate defects of all sizes, in all regions of the palate. Cosmetic deformity created from TM flap harvest may be addressed using cranioplasty implant placement, either primarily or during a second stage procedure. PMID:28680495
NASA Technical Reports Server (NTRS)
McCarty, John Locke; Brooks, George W.; Maglieri, Domenic J.
1959-01-01
A two-blade rotor having a diameter of 4 feet and a solidity of 0.037 was tested in the Langley 300-MPH 7- by 10-foot tunnel to obtain information on the effect of certain rotor variables on the blade periodic bending moments and flapping angles during the various stages of transformation between the helicopter and autogiro configuration. Variables studied included collective pitch angle, flapping-hinge offset, rotor angle of attack, and tip-speed ratio. The results show that the blade periodic bending moments generally increase with tip-speed ratio up into the transition region, diminish over a certain range of tip-speed ratio, and increase again at higher tip-speed ratios. Above the transition region, the bending moments increase with collective pitch angle and rotor angle of attack. The absence of a flapping hinge results in a significant amplification of the periodic bending moments, the magnitudes of which increase with tip-speed ratio. When the flapping hinge is used, an increase in flapping-hinge offset results in reduced period bending moments. The aforementioned trends exhibited by the bending moments for changes in the variables are essentially duplicated by the periodic flapping motions. The existence of substantial amounts of blade stall increased both the periodic bending moments and the flapping angles. Harmonic analysis of the bending moments shows significant contributions of the higher harmonics, particularly in the transition region.
Extending the use of the gracilis muscle flap in perineal reconstruction surgery.
Goldie, Stephen J; Almasharqah, Riyadh; Fogg, Quentin A; Anderson, William
2016-08-01
Reconstruction of the perineum is required following oncological resections. Plastic surgical techniques can be used to restore the aesthetics and function of the perineum. The gracilis myocutaneous flap provides a substantial skin paddle, with minimal donor site morbidity. The flap is pedicled on a perforator from the medial circumflex femoral artery, giving it limited reach across the perineum. Tunnelling the flap under the adductor longus muscle may free up more of the arterial pedicle, increasing its reach. On three female cadavers, bilateral gracilis flaps were raised in the standard surgical manner, giving six flaps in total. With the flaps pedicled across the perineum, the distance from the tip of each flap was measured to the anterior superior iliac spine (ASIS). The flaps were then tunnelled under the adductor longus muscle. The distances to the ASIS were measured again. The average pedicle length was greater than 7 cm. Tunnelling the flap under the adductor longus muscle increased the reach by more than 4 cm on average. Cadaveric dissection has shown that tunnelling of the flap in a novel way increase its reach across the perineum. This additional flexibility improves its use clinically and is of benefit to plastic surgeons operating in perineal reconstruction. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Acoustic characteristics of externally blown flap systems with mixer nozzles
NASA Technical Reports Server (NTRS)
Goodykoontz, J. H.; Dorsch, R. G.; Wagner, J. M.
1974-01-01
Noise tests were conducted on a large scale, cold flow model of an engine-under-the-wing externally blown flap lift augmentation system employing a mixer nozzle. The mixer nozzle was used to reduce the flap impingement velocity and, consequently, try to attenuate the additional noise caused by the interaction between the jet exhaust and the wing flap. Results from the mixer nozzle tests are summarized and compared with the results for a conical nozzle. The comparison showed that with the mixer nozzle, less noise was generated when the trailing flap was in a typical landing setting (e.g., 60 deg). However, for a takeoff flap setting (20 deg), there was little or no difference in the acoustic characteristics when either the mixer or conical nozzle was used.
Development of Bird-like Micro Aerial Vehicle with Flapping and Feathering Wing Motions
NASA Astrophysics Data System (ADS)
Maglasang, Jonathan; Goto, Norihiro; Isogai, Koji
To investigate the feasibility of a highly efficient flapping system capable of avian maneuvers, such as rapid takeoff, hover and gliding, a full scale bird-like (ornithopter) flapping-wing micro aerial vehicle (MAV) shaped and patterned after a typical pigeon (Columba livia) has been designed and constructed. Both numerical and experimental methods have been used in the development of this vehicle. This flapping-wing micro aerial vehicle utilizes both the flapping and feathering motions of an avian wing by employing a novel flapping-feathering mechanism, which has been synthesized and constructed so as to best describe the properly coordinated flapping and feathering wing motions at phase angle difference of 90° in a horizontal steady level flight condition. This design allows high flapping and feathering amplitudes and is configurable for asymmetric wing motions which are desirable in high-speed flapping flight and maneuvering. The preliminary results indicate its viability as a practical and an efficient flapping-wing micro aerial vehicle.
Indocyanine green fluorescence angiography for free flap monitoring: A pilot study.
Hitier, Marine; Cracowski, Jean-Luc; Hamou, Cynthia; Righini, Christian; Bettega, Georges
2016-11-01
We evaluated the feasibility and the tolerance of repeated fluorescent indocyanine green angiography in free flap monitoring, and determined the intraoperative predictive values of flap vitality. The free flap failure rate has been significantly reduced, but free flap loss still occurs and remains a costly disaster. Repeated clinical examinations are commonly used for flap monitoring, but they can be unreliable because of their subjectivity. Laser-induced fluorescence of indocyanine green is a new method for assessing tissue perfusion. 20 patients undergoing microsurgical reconstruction were monitored by indocyanine green fluorescence angiography, intraoperatively, and during 4 days after surgery, with 18 injections. Monitoring was made by clinical examination, and then compared to angiographic findings. The vascular complication rate was 15% (3/20) with 2 cases of venous thrombosis and one case of partial necrosis of the flap skin paddle. Both cases of venous thrombosis were salvaged by secondary surgery. There was no total flap loss. ICG angiography allowed detecting each intra and postoperative complication, earlier than clinical examination. The mean per-operative intensity of fluorescence was significantly lower in flaps with vascular complications (23.8 GL/ms; p = 0.008). The postoperative slope (p = 0.02) and amplitude (p = 0.03) of the fluorescent signal were both significantly lower than for uncomplicated flaps, before surgical revision. These 2 parameters came back to normal values after secondary surgery. There was no adverse effect of ICG despite the repeated injections. ICG angiography is a feasible and safe technique for the detection of free flap vascular complications. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Computational Study of Porous Treatment for Altering Flap Side-Edge Flowfield
NASA Technical Reports Server (NTRS)
Choudhari, Meelan; Khorrami, Mehdi R.
2003-01-01
Reynolds-averaged Navier-Stokes calculations are used to investigate porous side-edge treatment as a passive means for flap noise reduction. Steady-state simulations are used to infer effects of the treatment on acoustically relevant features of the mean flow near the flap side edge. Application of the porous treatment over a miniscule fraction of the wetted flap area (scaling with the flap thickness) results in significantly weaker side-edge vortex structures via modification of the vortex initiation and roll-up processes. At high flap deflections, the region of axial flow reversal associated with the breakdown of the side-edge vortex is also eliminated, indicating an absence of vortex bursting in the presence of the treatment. Potential ramifications of the mean-flow modifications for flap-noise reduction are examined in the light of lessons learned from recent studies on flap noise. Computations confirm that any noise reduction benefit via the porous treatment would be achieved without compromising the aerodynamic effectiveness of the flap. Results of the parameter study contribute additional insight into the measured data from the 7x10 wind tunnel at NASA Ames and provide preliminary guidance for specifying optimal treatment characteristics in terms of treatment location, spatial extent, and flow resistance of the porous skin.
Local vascularized flaps for augmentation of Reinke's space.
Dailey, Seth H; Gunderson, McLean; Chan, Roger; Torrealba, Jose; Kimura, Miwako; Welham, Nathan V
2011-02-01
The purpose of this study is to describe and test a novel surgical strategy for augmentation of Reinke's space using vascularized flaps: a thyroid ala perichondrium flap (TAP) and a composite thyroid ala perichondrium flap (CTAP) from the anterior larynx. We hypothesized that these specially designed vascularized flaps would remain viable once inset into the lamina propria, and that they would not disrupt rheologic, biomechanical, and histologic properties of the native vocal fold. Experimental. In vivo canine model. The length and volume of test flaps harvested in six adult human cadaveric larynges were analyzed to determine suitability for use in augmentation in the lamina propria. Also, 12 beagles randomly underwent unilateral placement of either TAP or CTAP, which were designed in accordance with the human adult cadaveric experiments. Flap perfusion was measured before and after harvest with laser Doppler. After 1 month, the beagles were humanely sacrificed and their larynges subjected to aerodynamic and acoustic evaluation using an excised larynx apparatus. The vocal fold lamina propria of four larynges--two TAP and two CTAP--underwent rheologic evaluation using a simple-shear rheometer. The remaining eight larynges underwent quantitative histologic and immunohistochemical evaluation. The survival and complication (swallowing, airway, local wound) rates of all dogs were noted. Initial studies with adult human cadaveric larynges established that TAP and CTAP possessed length and volume greater than native lamina propria. In the canine experiments, the perfusion change in the flaps was similar between flap groups. The damping ratio (ζ), dynamic viscosity (η'), elastic shear modulus (G'), and viscous shear modulus (G″) of treated and untreated native vocal folds were not statistically different. The glottic function measures of vocal efficiency, laryngeal resistance, jitter, shimmer, and harmonics-to-noise ratio (HNR) of treated and normal larynges were not
Subcutaneous pedicle propeller flap: An old technique revisited and modified!
Karki, Durga; Mehta, Nikhil; Narayan, Ravi Prakash
2016-01-01
Post-burn axillary and elbow scar contracture is a challenging problem to the reconstructive surgeon owing to the wide range of abduction and extension that should be achieved, respectively, while treating either of the joint. The aim of this paper is to highlight the use of subcutaneous pedicle propeller flap for the management of post-burn axillary and elbow contractures. This is a prospective case study of axillary and elbow contractures managed at a tertiary care hospital using propeller flap based on subcutaneous pedicle from 2009 to 2014. Surgical treatment comprised of subcutaneous-based pedicle propeller flap from the normal tissue within the contracture based on central axis pedicle. The flap was rotated axially to break the contracture. The technique further encompassed a modification, a Zig-Zag incision of the flap, which was seen to prevent hypertrophy along the incision line. There was a mean period of 12 months of follow-up. Thirty-eight patients consisting of 22 males and 16 females were included in this study among which 23 patients had Type II axillary contractures and 15 had moderate flexion contractures at elbow joint. The post-operative abduction achieved at shoulder joint had a mean of 168° whereas extension achieved at elbow had a mean of 175°. The functional and aesthetic results were satisfactory. The choice of surgical procedure for reconstruction of post-burn upper extremity contractures should be made according to the pattern of scar contracture and the state of surrounding skin. The choice of subcutaneous pedicle propeller flap should be emphasised because of the superior functional results of flap as well as ease to learn it. Moreover, the modification of propeller flap described achieves better results in terms of scar healing. There is an inter-positioning of healthy skin in between the graft, so it prevents scar band formation all around the flap.
Angiotensin II improves random-flap viability in a rat model.
Okuyama, N; Roda, N; Sherman, R; Guerrero, A; Dougherty, W; Nguyen, T; diZerega, G; Rodgers, K
1999-03-01
Angiotensin II (AII) is a naturally occurring peptide that has been shown to be angiogenic, cause the proliferation of several primary cell types (including endothelial cells), accelerate the repair of dermal injuries, and increase production of growth factors and extracellular matrix. The effect of a single administration of AII on the viability and vascularity of a random flap was assessed in a rat model. In the control model, the viability of the distal portion of the flap was reduced consistently by postoperative day 8. Initially, AII was administered in an aqueous vehicle (phosphate-buffered saline [PBS]) and a viscous vehicle (10% carboxymethyl cellulose [CMC]). Administration of 1 mg per milliliter AII in PBS did not affect the viability of random flaps (1.2 x 7 cm) in this animal model. However, a single administration of a higher dose of AII in PBS (10 mg per milliliter) or 1 mg per milliliter AII in the CMC vehicle resulted in 67% of the grafts being fully viable at postsurgical day 12, in contrast to vehicle-treated control flaps, none of which were fully viable at day 12. Furthermore, the portion of the flap that was viable was increased significantly (p < or = 0.05). Subsequently, a study was conducted to assess the dose-response curve for AII in a CMC vehicle in this rat model. As the dose of AII was reduced, the percentage of animals with fully viable flaps and the percentage of the flap that was viable decreased correspondingly. Administration of 0.03 mg per milliliter AII and greater increased significantly (p < or = 0.05) the viability of the flaps. In conclusion, AII appears to be highly efficacious in increasing the percentage of distal flap surface area survival when administered as a single topical dose to the wound bed.
[Clinical experience with the supraclavicular flap to reconstruct head and neck defects].
Zhang, Bin; Yan, Dangui; Zhang, Yabing; Zhang, Xiwei; Wan, Hanfeng
2015-06-01
To evaluate the efficacy of pedicled supraclavicular artery island flaps for head and neck reconstruction. Reconstructive surgeries for head and neck oncologic defects were performed with the pedicled supraclavicular artery island flaps in 10 patients from May 2013 to December 2014 and the cases were review. Among them, 6 were performed for hypopharyngeal cancer, 2 for oral tongue cancer, 1 for oral base cancer and 1 for cervical esophageal cancer. The size of the flaps was measured in (5-8) cm × (6-12) cm. Seven flaps survived, one flap failured and two flaps had partial necrosis. Donor sites were closed primarily without morbidity. The pedicled supraclavicular artery island flap is an easy harvesting and reliable for head and neck reconstruction, especially suitable for otolaryngo-head and neck surgeon and maxillofacial surgeon in the local hospital.
Analysis of a Multi-Flap Control System for a Swashplateless Rotor
NASA Technical Reports Server (NTRS)
Sekula, Martin K.; Wilbur, Matthew L.
2011-01-01
An analytical study was conducted examining the feasibility of a swashplateless rotor controlled through two trailing edge flaps (TEF), where the cyclic and collective controls were provided by separate TEFs. This analysis included a parametric study examining the impact of various design parameters on TEF deflections. Blade pitch bearing stiffness; blade pitch index; and flap chord, span, location, and control function of the inboard and outboard flaps were systematically varied on a utility-class rotorcraft trimmed in steady level flight. Gradient-based optimizations minimizing flap deflections were performed to identify single- and two-TEF swashplateless rotor designs. Steady, forward and turning flight analyses suggest that a two-TEF swashplateless rotor where the outboard flap provides cyclic control and inboard flap provides collective control can reduce TEF deflection requirements without a significant impact on power, compared to a single-TEF swashplateless rotor design.
Non-invasive terahertz imaging of tissue water content for flap viability assessment
Bajwa, Neha; Au, Joshua; Jarrahy, Reza; Sung, Shijun; Fishbein, Michael C.; Riopelle, David; Ennis, Daniel B.; Aghaloo, Tara; St. John, Maie A.; Grundfest, Warren S.; Taylor, Zachary D.
2016-01-01
Accurate and early prediction of tissue viability is the most significant determinant of tissue flap survival in reconstructive surgery. Perturbation in tissue water content (TWC) is a generic component of the tissue response to such surgeries, and, therefore, may be an important diagnostic target for assessing the extent of flap viability in vivo. We have previously shown that reflective terahertz (THz) imaging, a non-ionizing technique, can generate spatially resolved maps of TWC in superficial soft tissues, such as cornea and wounds, on the order of minutes. Herein, we report the first in vivo pilot study to investigate the utility of reflective THz TWC imaging for early assessment of skin flap viability. We obtained longitudinal visible and reflective THz imagery comparing 3 bipedicled flaps (i.e. survival model) and 3 fully excised flaps (i.e. failure model) in the dorsal skin of rats over a postoperative period of 7 days. While visual differences between both models manifested 48 hr after surgery, statistically significant (p < 0.05, independent t-test) local differences in TWC contrast were evident in THz flap image sets as early as 24 hr. Excised flaps, histologically confirmed as necrotic, demonstrated a significant, yet localized, reduction in TWC in the flap region compared to non-traumatized skin. In contrast, bipedicled flaps, histologically verified as viable, displayed mostly uniform, unperturbed TWC across the flap tissue. These results indicate the practical potential of THz TWC sensing to accurately predict flap failure 24 hours earlier than clinical examination. PMID:28101431
Where Does the Transplanted Fat is Located in the Gluteal Region? Research Letter.
Ramos-Gallardo, Guillermo; Medina-Zamora, Pablo; Cardenas-Camarena, Lázaro; Orozco-Rentería, David; Duran-Vega, Héctor; Mota-Fonseca, Eduardo
2017-12-29
Liposuction is one of the most popular plastic surgery procedures. As in any surgery, there are risks and complications, especially when combined with fat injection. Case reports of fat embolism have been reported. A possible explanation is the puncture and tearing of gluteal vessels during the procedure, especially when a deep injection is planned. To identify the places where fat can be located after injection during a fat graft in the gluteus. An experimental study was done in which colorant was injected in four directions using four different quadrants of the gluteus. We Injected 10 cc six times following clock hands until 60 cc were injected, and the cutaneous flap and the muscles were then elevated. Our main purpose was to describe where the colorant went and if it was in contact with the vessels (superior and inferior gluteal vessels). In total, four gluteus muscles were injected and dissected. Injection in the lower lateral quadrant was mainly into the muscle, and colorant was observed in the hypogastric vessels. The injection in the upper quadrants stayed mainly in the subcutaneous tissue. During surgery, it is important to identify the location of the perforators and to avoid a deep injection, especially from the lower lateral quadrant to the superior medial quadrant (Q4 to Q1), as the probability of puncturing and injecting fat into the main vessels from this direction is higher.
Effects of lidocaine on random skin flap survival in rats.
Cao, Bin; Wang, Liren; Lin, Dingsheng; Cai, Leyi; Gao, Weiyang
2015-01-01
Use of a random skin flap is common for repairing wounds and for reconstruction. Lidocaine is a traditional local anesthetic that blocks sodium channels and has positive effects on ischemia-reperfusion injury. To investigate the effects of lidocaine on random skin flap survival in rats. McFarlane flaps were established in 20 rats divided into 2 groups. Lidocaine was injected in the lidocaine group, and the same concentration of saline was injected in the control group. The survival area of the flaps was measured on Day 7. Levels of inflammation were evaluated by hematoxylin and eosin (H&E)-stained slices, and superoxide dismutase and malonyldialdehyde contents were examined. The mean survival area of the flaps in the lidocaine group was significantly larger than that in the control group. Superoxide dismutase activity increased significantly in the lidocaine group compared with that in the control group. Malonyldialdehyde level in the lidocaine group was significantly lower than that in the control group. The H&E-stained slices showed that inflammation was clearly inhibited in the lidocaine group. Lidocaine improved the survival of random skin flaps.
Free-flap surgical correction of facial deformity after anteromedial maxillectomy.
Sarukawa, Shunji; Kamochi, Hideaki; Noguchi, Tadahide; Sunaga, Ataru; Uda, Hirokazu; Mori, Yoshiyuki; Nishino, Hiroshi; Yoshimura, Kotaro
2017-09-01
Anteromedial maxillectomy is typically performed in conjunction with low-dose radiotherapy and intraarterial chemotherapy. In doing so, the extent of surgical defects is reduced. However, nasal deviation and oral incompetence may ensue, due to cicatricial contracture of wounds, and may be distressing to these patients. Herein, we report a series of eight free perforator flap procedures (anterolateral thigh [ALT] flap, 6; thoracodorsal artery perforator [TAP] flap, 2) used to correct such deformities. The TAP flap was combined with scapular tip [ST] osseous flap in patients with added zygomatic prominence defects. Three adipocutaneous parts developed from each perforator flap were applied as follows: two to reconstruct nasal lining and oral vestibule, and one to augment cheek volume. All aesthetic results proved satisfactory, although orbital dystopia and contracture of mimic muscles were not resolved completely. These secondary interventions are suitable for sequelae of simple anteromedial maxillectomy. Immediate reconstruction should be considered if orbital floor and mimic muscles are involved. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Prefabricated fibula free flap with dental implants for mandibular reconstruction.
Pauchet, D; Pigot, J-L; Chabolle, F; Bach, C-A
2018-03-02
Free fibula transplant is routinely used for mandibular reconstruction in head and neck cancer. Dental rehabilitation, the objective of mandibular reconstruction, requires the use of dental implants as supports for fixed or removable dentures. Positioning of fibular bone grafts and implants determines implant osseointegration and the possibilities of dental rehabilitation. Prefabrication of a fibula free flap with dental implants prior to harvesting as a free flap can promote implant osseointegration. The position of the implants must then be precisely planned. Virtual surgery and computer-assisted design and prefabrication techniques are used to plan the reconstruction and then reproduce this planning by means of tailored fibula and mandible cutting guides, thereby ensuring correct positioning of fibular bone fragments and implants. The prefabricated fibula free flap technique requires two surgical procedures (prefabrication and flap transfer) and precise preoperative planning. Prefabricated fibula free flap with dental implants, by improving the quality of osseointegration of the implants before flap transfer, extends the possibilities of prosthetic rehabilitation in complex secondary mandibular reconstructions. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
PECASE: Soaring Mechanisms for Flapping-Wing Micro Air Vehicles
2015-03-31
2015 2. REPORT TYPE Final 4. TITLE AND SUBTITLE PECASE: Soaring mechanisms for flapping - wing micro air vehicles 6. AUTHOR(S) Robert J. Wood 3...N00014-10-1-0684 Award Title: "PECASE: Soaring mechanisms for flapping - wing micro air vehicles" [previous award: N00014-08-1-0919, "Hovering Control for...Insect-Inspired Flapping - Wing Micro Air Vehicles"] Final report a. Scientific and Technical Objectives The Harvard Microrobotics Lab has
Internal-external flow integration for a thin ejector-flapped wing section
NASA Technical Reports Server (NTRS)
Woolard, H. W.
1979-01-01
Thin airfoil theories of an ejector flapped wing section are reviewed. The global matching of the external airfoil flow with the ejector internal flow and the overall ejector flapped wing section aerodynamic performance are examined. Mathematical models of the external and internal flows are presented. The delineation of the suction flow coefficient characteristics are discussed. The idealized lift performance of an ejector flapped wing relative to a jet augmented flapped wing are compared.
The double-opposing buccal flap procedure for palatal lengthening.
Mann, Robert J; Neaman, Keith C; Armstrong, Shannon D; Ebner, Ben; Bajnrauh, Robert; Naum, Steven
2011-06-01
Velopharyngeal dysfunction has been treated with either a pharyngeal flap or sphincteroplasty with varying degrees of success. Both of these entities have their own series of problems, with sleep apnea and nasal mucous flow disruptions at the forefront. The purpose of this study was to review the senior author's (R.J.M.) experience performing the double-opposing buccal flap for palatal lengthening. All patients who were treated with double-opposing buccal flaps between October of 1994 and July of 2007 were reviewed. These patients presented with varying degrees of velopharyngeal dysfunction showing some degree of velar movement at the time of surgery. Preoperative and postoperative speech results were reviewed for comparison. Twenty-seven patients underwent palatal lengthening, with an average length of follow-up of 58 months. Distal flap necrosis occurred in two patients. The level of intelligibility (65.4 percent versus 95.5 percent) and resonance (moderately hypernasal versus normal resonance) improved significantly postoperatively (p < 0.0001). Only one patient required the addition of a pharyngeal flap for persistent velopharyngeal dysfunction, and there were no postoperative issues with sleep apnea. The double-opposing buccal flap is an effective technique for lengthening the palate, improving speech, and decreasing the risks of postoperative sleep apnea. All patients experienced a dramatic improvement in their resonance and intelligibility. This technique appears most effective in patients with intact velar movement who demonstrate a small to moderate posterior velar gap. The double-opposing buccal flap is a useful means of treating velopharyngeal dysfunction, thus serving as an adjunct when improving pharyngeal closure.
Comparison of laser in situ keratomileusis flaps created by 2 femtosecond lasers.
Zheng, Yan; Zhou, Yuehua; Zhang, Jing; Liu, Qian; Zhai, Changbin; Wang, Yonghua
2015-03-01
To compare flap morphology created by the WaveLight FS200 femtosecond laser and the VisuMax femtosecond laser, assessing the uniformity, accuracy, and predictability of flap creation. A total of 400 eyes had corneal flaps created with the WaveLight FS200 femtosecond laser (200 eyes) or the VisuMax femtosecond laser (200 eyes). The desired flap thickness was 110 μm. At 1 week postoperatively, all eyes were evaluated with RTVue Fourier-domain optical coherence tomography. Dimensions of the flaps were tested for their regularity, uniformity, accuracy, and predictability comparison. One week after surgery, the central flap thickness and the mean flap thickness of the FS200 group were 105.4 ± 3.4 μm and 105.7 ± 2.6 μm, respectively. They were both thinner than those of the VisuMax group, which were 110.8 ± 3.9 μm and 111.3 ± 2.3 μm, respectively. The mean deviation between the achieved and attempted flap thickness of the FS200 group (5.2 ± 1.9 μm) was greater than that of the VisuMax group (3.2 ± 1.8 μm). Flap thickness measurements at 36 points in both groups were close to the intended thickness. Morphology of the flaps in the 0-, 45-, 90-, and 135-degree lines created by the FS200 femtosecond laser and VisuMax femtosecond laser were uniform and regular. Flap dimensions created by the WaveLight FS200 femtosecond laser and VisuMax femtosecond laser were uniform and regular. Although the flap thickness created by the FS200 was less than that created by the VisuMax, measurements of both femtosecond lasers were close to the intended thickness.
Divided and Sliding Superficial Temporal Artery Flap for Primary Donor-site Closure
Sugio, Yuta; Seike, Shien; Hosokawa, Ko
2016-01-01
Summary: Superficial temporal artery (STA) flaps are often used for reconstruction of hair-bearing areas. However, primary closure of the donor site is not easy when the size of the necessary skin island is relatively large. In such cases, skin grafts are needed at the donor site, resulting in baldness. We have solved this issue by applying the divided and sliding flap technique, which was first reported for primary donor-site closure of a latissimus dorsi musculocutaneous flap. We applied this technique to the hair-bearing STA flap, where primary donor-site closure is extremely beneficial for preventing baldness consequent to skin grafting. The STA flap was divided into 3, and creation of large flap was possible. Therefore, we concluded that the divided and sliding STA flap could at least partially solve the donor-site problem. Although further investigation is necessary to validate the maximum possible flap size, this technique may be applicable to at least small defects that are common after skin cancer ablation or trauma. PMID:27975020
Levator alae nasi muscle V-Y island flap for nasal tip reconstruction.
La Padula, Simone; Abbate, Vincenzo; Di Monta, Gianluca; Schonauer, Fabrizio
2017-03-01
Nasal tip reconstruction can be very challenging. It requires close attention to skin texture, colour and thickness matching, with the respect of the nasal aesthetic units and symmetry. Flaps are usually preferred to skin grafts where possible. Based on different donor areas, various flaps have been described for reconstruction of this region. Here we present a new V-Y myocutaneous island flap based on the levator alae nasi muscle (LAN muscle) blood supply. This flap may represent an alternative to the nasalis myocutaneous sliding V-Y flap previously described by Rybka. As its pivot point it is located more cranially than the nasalis flap, and it can advance more medially than the Rybka flap, with the possibility of covering larger defects of the nasal tip area, up to 1.8 cm in diameter. Over the past 5 years, 24 patients received nasal tip reconstruction with this flap following the resection of basal cell carcinomas. Good tip projection was maintained, and the aesthetic outcome was satisfactory, with well healed scars. We recommend this technique as an alternative to other flaps for nasal tip defects, especially if paramedian. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Kajikawa, Akiyoshi; Ueda, Kazuki; Katsuragi, Yoko; Hirose, Taro; Asai, Emiko
2010-10-01
Facial defect after an extended total maxillectomy is one of the most difficult deformities to reconstruct aesthetically, because the defect is not only large but also three-dimensional. Although free-flap reconstruction is useful, the patchwork-like scar, bad colour match and poor texture match are major problems. The contracture and displacement of the reconstructed eyelids and eye socket are also serious matters. To resolve these problems, we have performed a three-step reconstruction using a free rectus abdominis myocutaneous (RAM) flap and an expanded cervicofacial flap with cartilage grafts. In the first step, a free RAM flap was transplanted to the defect after extended total maxillectomy. In the second step, tissue expanders were placed under the skin of the cheek and neck a year after the RAM flap transplantation. After expansion of the cheek and neck skin, the third step was performed. The inferior part of the external skin island of the RAM flap was raised and sutured to the superior margin of the skin island to create a pouch for the eye socket. Costal cartilage was grafted to reconstruct the orbital floor and malar prominence, and auricular cartilage was grafted to reconstruct the tarsal plates. Finally, the expanded cervicofacial flap was rotated to cover this construct. Two weeks after reconstruction, the neo-eyelids were divided to form the lid fissure. We performed the three-step reconstruction on six cases after extended total maxillectomy. In all cases, a deep and stable eye socket was reconstructed. The reconstructed eyelids and cheek were natural in appearance with good colour and texture match without conspicuous scars. To obtain symmetry and natural appearance in the orbitomaxillary reconstruction, there are five points that should be formed; the eye socket, the groundwork of the eye socket, the orbital floor and malar prominence, the tarsal plates and the surface of the eyelids and cheek. We do not reconstruct the palate to set prosthetic
Reverse Saphenous Conduit Flap in 19 Dogs and 1 Cat.
Cavalcanti, Jacqueline V J; Barry, Sabrina L; Lanz, Otto I; Barnes, Katherine; Coutin, Julia V
2018-05-14
The purpose of this retrospective study was to report the outcomes of 19 dogs and 1 cat undergoing reverse saphenous conduit flap between 1999 and 2016. Reverse saphenous conduit flap was used to treat traumatic wounds and wounds resulting from tumor excision in the hind limb; the majority of cases had medial shearing injuries. All animals had complete flap survival. In five animals (20%), minor donor site dehiscence occurred, which did not require surgery. Other postoperative complications included signs of severe venous congestion in one dog. Reverse saphenous conduit flap is a useful technique to repair skin defects of the distal hind limb.
Noise tests of a mixer nozzle-externally blown flap system
NASA Technical Reports Server (NTRS)
Goodykoontz, J. H.; Dorsch, R. G.; Groesbeck, D. E.
1973-01-01
Noise tests were conducted on a large scale model of an externally blown flap lift augmentation system, employing a mixer nozzle. The mixer nozzle consisted of seven flow passages with a total equivalent diameter of 40 centimeters. With the flaps in the 30 - 60 deg setting, the noise level below the wing was less with the mixer nozzle than when a standard circular nozzle was used. At the 10 - 20 deg flap setting, the noise levels were about the same when either nozzle was used. With retracted flaps, the noise level was higher when the mixer nozzle was used.
The superior gluteal artery perforator flap for reconstruction of sacral sores
Chen, Weijian; Jiang, Bo; Zhao, Jiaju; Wang, Peiji
2016-01-01
This report describes our experiences using the superior gluteal artery perforator (SGAP) flaps for reconstruction of 2 sacral sore cases. A 47-year-old female patient and a 38-year-old man with sacral sores were treated in our unit. The size of the defects were approximately 5×6 cm2 and 8×9 cm2, the defects were repaired by SGAP flaps. The size of designed was SGAP flaps varied from 7×20 to 9×16 cm2. All flaps survived and healed primary, the texture, functions, and appearance of flaps were satisfactory, and also without region dysfunction of donor and recipient sites. The SGAP flap, which has reliable blood supply, preserves the gluteus maximus muscle and could be transferred simply and safely, is an ideal and reusable method to reconstruct sacral sores with low rate of postoperative recurrence and satisfactory appearance. PMID:27652367
Efficiency of lift production in flapping and gliding flight of swifts.
Henningsson, Per; Hedenström, Anders; Bomphrey, Richard J
2014-01-01
Many flying animals use both flapping and gliding flight as part of their routine behaviour. These two kinematic patterns impose conflicting requirements on wing design for aerodynamic efficiency and, in the absence of extreme morphing, wings cannot be optimised for both flight modes. In gliding flight, the wing experiences uniform incident flow and the optimal shape is a high aspect ratio wing with an elliptical planform. In flapping flight, on the other hand, the wing tip travels faster than the root, creating a spanwise velocity gradient. To compensate, the optimal wing shape should taper towards the tip (reducing the local chord) and/or twist from root to tip (reducing local angle of attack). We hypothesised that, if a bird is limited in its ability to morph its wings and adapt its wing shape to suit both flight modes, then a preference towards flapping flight optimization will be expected since this is the most energetically demanding flight mode. We tested this by studying a well-known flap-gliding species, the common swift, by measuring the wakes generated by two birds, one in gliding and one in flapping flight in a wind tunnel. We calculated span efficiency, the efficiency of lift production, and found that the flapping swift had consistently higher span efficiency than the gliding swift. This supports our hypothesis and suggests that even though swifts have been shown previously to increase their lift-to-drag ratio substantially when gliding, the wing morphology is tuned to be more aerodynamically efficient in generating lift during flapping. Since body drag can be assumed to be similar for both flapping and gliding, it follows that the higher total drag in flapping flight compared with gliding flight is primarily a consequence of an increase in wing profile drag due to the flapping motion, exceeding the reduction in induced drag.
Efficiency of Lift Production in Flapping and Gliding Flight of Swifts
Henningsson, Per; Hedenström, Anders; Bomphrey, Richard J.
2014-01-01
Many flying animals use both flapping and gliding flight as part of their routine behaviour. These two kinematic patterns impose conflicting requirements on wing design for aerodynamic efficiency and, in the absence of extreme morphing, wings cannot be optimised for both flight modes. In gliding flight, the wing experiences uniform incident flow and the optimal shape is a high aspect ratio wing with an elliptical planform. In flapping flight, on the other hand, the wing tip travels faster than the root, creating a spanwise velocity gradient. To compensate, the optimal wing shape should taper towards the tip (reducing the local chord) and/or twist from root to tip (reducing local angle of attack). We hypothesised that, if a bird is limited in its ability to morph its wings and adapt its wing shape to suit both flight modes, then a preference towards flapping flight optimization will be expected since this is the most energetically demanding flight mode. We tested this by studying a well-known flap-gliding species, the common swift, by measuring the wakes generated by two birds, one in gliding and one in flapping flight in a wind tunnel. We calculated span efficiency, the efficiency of lift production, and found that the flapping swift had consistently higher span efficiency than the gliding swift. This supports our hypothesis and suggests that even though swifts have been shown previously to increase their lift-to-drag ratio substantially when gliding, the wing morphology is tuned to be more aerodynamically efficient in generating lift during flapping. Since body drag can be assumed to be similar for both flapping and gliding, it follows that the higher total drag in flapping flight compared with gliding flight is primarily a consequence of an increase in wing profile drag due to the flapping motion, exceeding the reduction in induced drag. PMID:24587260
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rees, Thomas D.
1961-01-01
Successful repair by plastic surgery of nonhealing ulceration of the chest wall, induced by radiotherapy for breast cancer, is described. Reconstruction of the chest wali defect by pedicle flap coverage was carried out. Radiation injury extended through the entire thickness of the chest wall and osteoradionecrosis of the ribs was present. Reconstruction with thoracoabdominal tube was considered to be the best technique, so a 4- by 9-in. tube pedicle was constructed. The underlying donor wound of the pedicle was covered with a split- thickness skin graft. Healing was without incident, and approximates 3 weeks after formation, the inferior end ofmore » this tube pedicle was migrated to the left epigastrium as an intermediate step. Healing was uncomplicated, and the lateral attachment of the pedicle was partially severed. Three weeks later, resection of all avascular tissue along with portions of the fourth and fifth ribs was carried out. This created a full-thickness chest wall defect measuring 4 by 8 in., with the anterior surface of the pericardial sac exposed in the wound. The end of the abdominal tube pedicle was elevated from its bed, rotated into position, and sutured to the healthy margins of the chest wall defect. The exposed subcutaneous fat of the undersurface of the pedicle was placed in juxtaposition to the pericardium. A split-thickness skin graft was cut from the skin of the left thigh and draped over the pedicle flap donor wound. All sutured wounds healed per primum and the entire skin graft survived. The inferior inset of the tube pedicle was cut free and the pedicle flap was tailored into position 6 weeks later. The patient was discharged from the hospital in good condition and engaged in normal activities. An attempt was made to provide protection for the heart beneath the pedicle inset by introduction of diced homologous cartilage grafts, just beneath the skin of the pedicle flap. This healed with the formation of a thick fibrocartilaginous
Latissimus Dorsi Flap in Breast Reconstruction
Sood, Rachita; Easow, Jeena M.; Konopka, Geoffrey; Panthaki, Zubin J.
2018-01-01
Background: Surgeons employ the latissimus dorsi flap (LDF) for reconstruction of a large variety of breast cancer surgery defects, including quadrantectomy, lumpectomy, modified radical mastectomy, and others. The LDF may be used in delayed or immediate reconstruction, in combination with tissue expanders for a staged reconstruction, with implant-based immediate reconstruction, or alone as an autogenous flap. Methods: The authors discuss the historical uses and more recent developments in the LDF. More recent advancements, including the “scarless” approach and augmentation with the thoracodorsal artery perforator flap, are discussed. Results: The LDF is a reliable means for soft tissue coverage providing form and function during breast reconstruction with acceptable perioperative and long-term morbidities. Conclusions: When there is a paucity of tissue, the LDF can provide tissue volume in autologous reconstruction, as well as a reliable vascular pedicle for implant-based reconstruction as in the setting of irradiated tissue. PMID:29334788
The Utility and Versatility of Perforator-Based Propeller Flaps in Burn Care.
Teven, Chad M; Mhlaba, Julie; O'Connor, Annemarie; Gottlieb, Lawrence J
The majority of surgical burn care involves the use of skin grafts. However, there are cases when flaps are required or provide superior outcomes both in the acute setting and for postburn reconstruction. Rarely discussed in the context of burn care, the perforator-based propeller flap is an important option to consider. We describe our experience with perforator-based propeller flaps in the acute and reconstructive phases of burn care. We reviewed demographics, indications, operative details, and outcomes for patients whose burn care included the use of a perforator-based propeller flap at our institution from May 2007 to April 2015. Details of the surgical technique and individual cases are also discussed. Twenty-one perforator-based propeller flaps were used in the care of 17 burn patients. Six flaps (29%) were used in the acute phase for coverage of exposed joints, tendons, cartilage, and bone; coverage of open wounds; and preservation of range of motion (ROM) by minimizing scar contracture. Fifteen flaps (71%) were used for reconstruction of postburn deformities including coverage of chronic wounds, for coverage after scar contracture release, and to improve ROM. The majority of flaps (94% at follow-up) exhibited stable soft tissue coverage and good or improved ROM of adjacent joints. Three cases of partial flap loss and one case of total flap loss occurred. Perforator-based propeller flaps provide reliable vascularized soft tissue for coverage of vital structures and wounds, contracture release, and preservation of ROM across joints. Despite a relatively significant risk of minor complications particularly in the coverage of chronic wounds, our study supports their utility in both the acute and reconstructive phases of burn care.
"Palmar pivot flap" for resurfacing palmar lateral defects of the fingers.
Yam, Andrew; Peng, Yeong-Pin; Pho, Robert Wan-Heng
2008-12-01
Soft tissue defects on the lateral borders of the digits are difficult to reconstruct using local or local-regional flaps. We describe a "palmar pivot flap" to resurface an adjacent defect on the palmar-lateral aspect of the digit. The surgical technique is described. This flap is an axial pattern flap based on the subcutaneous transverse branches of the digital artery. The flap is pivoted up to 90 degrees on the neurovascular bundle in its base, into an adjacent defect. The flap can be raised from either the proximal or the middle phalangeal segments. It can cover defects sited from the level of the proximal interphalangeal joint up to the fingertip. The donor defect is limited to the same digit and is covered with a full-thickness skin graft. We have used this flap on 3 patients with defects at the middle phalangeal segment, the distal interphalangeal joint, and the fingertip. All healed primarily. One patient had a mild flexion contracture of the proximal interphalangeal joint, whereas the other 2 had no complications. The patients with distal interphalangeal joint and fingertip defects had excellent sensation in the flap (2-point discrimination of 5-6 mm). The palmar pivot flap is useful for resurfacing otherwise difficult defects on the lateral borders of the digits around and distal to the proximal interphalangeal joint, including those at the fingertip. It provides sensate, glabrous skin. The donor defect is on the same digit and is well hidden, producing an aesthetic and functional reconstruction.
Naringin improves random skin flap survival in rats
Cheng, Liang; Chen, Tingxiang; Tu, Qiming; Li, Hang; Feng, Zhenghua; Li, Zhijie; Lin, Dingsheng
2017-01-01
Background Random-pattern flap transfer is commonly used to treat soft-tissue defects. However, flap necrosis remains a serious problem. Naringin accelerates angiogenesis by activating the expression of vascular endothelial growth factor (VEGF). In the present study, we investigated whether naringin improves the survival of random skin flaps. Results Compared with controls, the naringin-treated groups exhibited significantly larger mean areas of flap survival, significantly increased SOD activity and VEGF expression, and significantly reduced MDA level. Hematoxylin and eosin (HE) staining revealed that naringin promoted angiogenesis and inhibited inflammation. Materials and Methods “McFarlane flap” models were established in 90 male Sprague-Dawley (SD) rats divided into three groups: a 40 mg/kg control group (0.5 % sodium carboxymethylcellulose), a 40 mg/kg naringin-treated group, and an 80 mg/kg naringin-treated group. The extent of necrosis was measured 7 days later, and tissue samples were subjected to histological analysis. Angiogenesis was evaluated via lead oxide–gelatin angiography, immunohistochemistry, and laser Doppler imaging. Inflammation was evaluated by measurement of serum TNF-α (tumor necrosis factor-α) and IL-6 (interleukin-6) levels. Oxidative stress was assessed by measuring superoxide dismutase (SOD) activity and the malondialdehyde (MDA) level. Conclusion Naringin improved random skin flap survival. PMID:29212216
Flapping wing flight can save aerodynamic power compared to steady flight.
Pesavento, Umberto; Wang, Z Jane
2009-09-11
Flapping flight is more maneuverable than steady flight. It is debated whether this advantage is necessarily accompanied by a trade-off in the flight efficiency. Here we ask if any flapping motion exists that is aerodynamically more efficient than the optimal steady motion. We solve the Navier-Stokes equation governing the fluid dynamics around a 2D flapping wing, and determine the minimal aerodynamic power needed to support a specified weight. While most flapping wing motions are more costly than the optimal steady wing motion, we find that optimized flapping wing motions can save up to 27% of the aerodynamic power required by the optimal steady flight. We explain the cause of this energetic advantage.
Parametric study of fluid flow manipulation with piezoelectric macrofiber composite flaps
NASA Astrophysics Data System (ADS)
Sadeghi, O.; Tarazaga, P.; Stremler, M.; Shahab, S.
2017-04-01
Active Fluid Flow Control (AFFC) has received great research attention due to its significant potential in engineering applications. It is known that drag reduction, turbulence management, flow separation delay and noise suppression through active control can result in significantly increased efficiency of future commercial transport vehicles and gas turbine engines. In microfluidics systems, AFFC has mainly been used to manipulate fluid passing through the microfluidic device. We put forward a conceptual approach for fluid flow manipulation by coupling multiple vibrating structures through flow interactions in an otherwise quiescent fluid. Previous investigations of piezoelectric flaps interacting with a fluid have focused on a single flap. In this work, arrays of closely-spaced, free-standing piezoelectric flaps are attached perpendicular to the bottom surface of a tank. The coupling of vibrating flaps due to their interacting with the surrounding fluid is investigated in air (for calibration) and under water. Actuated flaps are driven with a harmonic input voltage, which results in bending vibration of the flaps that can work with or against the flow-induced bending. The size and spatial distribution of the attached flaps, and the phase and frequency of the input actuation voltage are the key parameters to be investigated in this work. Our analysis will characterize the electrohydroelastic dynamics of active, interacting flaps and the fluid motion induced by the system.
Biomimetic Beetle-Inspired Flapping Air Vehicle Actuated by Ionic Polymer-Metal Composite Actuator
Zhao, Yang; Xu, Di; Sheng, Jiazheng; Meng, Qinglong; Wu, Dezhi; Wang, Lingyun; Xiao, Jingjing; Lv, Wenlong; Sun, Daoheng
2018-01-01
During the last decades, the ionic polymer-metal composite (IPMC) received much attention because of its potential capabilities, such as large displacement and flexible bending actuation. In this paper, a biomimetic flapping air vehicle was proposed by combining the superiority of ionic polymer metal composite with the bionic beetle flapping principle. The blocking force was compared between casted IPMC and IPMC. The flapping state of the wing was investigated and the maximum displacement and flapping angle were measured. The flapping displacement under different voltage and frequency was tested. The flapping displacement of the wing and the support reaction force were measured under different frequency by experiments. The experimental results indicate that the high voltage and low frequency would get large flapping displacement. PMID:29682006
Biomimetic Beetle-Inspired Flapping Air Vehicle Actuated by Ionic Polymer-Metal Composite Actuator.
Zhao, Yang; Xu, Di; Sheng, Jiazheng; Meng, Qinglong; Wu, Dezhi; Wang, Lingyun; Xiao, Jingjing; Lv, Wenlong; Chen, Qinnan; Sun, Daoheng
2018-01-01
During the last decades, the ionic polymer-metal composite (IPMC) received much attention because of its potential capabilities, such as large displacement and flexible bending actuation. In this paper, a biomimetic flapping air vehicle was proposed by combining the superiority of ionic polymer metal composite with the bionic beetle flapping principle. The blocking force was compared between casted IPMC and IPMC. The flapping state of the wing was investigated and the maximum displacement and flapping angle were measured. The flapping displacement under different voltage and frequency was tested. The flapping displacement of the wing and the support reaction force were measured under different frequency by experiments. The experimental results indicate that the high voltage and low frequency would get large flapping displacement.
The Trapezius Muscle Flap: A Viable Alternative for Posterior Scalp and Neck Reconstruction.
Yang, Hee Jun; Lee, Dong Hun; Kim, Yang Woo; Lee, Sang Gu; Cheon, Young Woo
2016-11-01
The trapezius muscle flap is not usually the first reconstructive option for skin and soft tissue defects in the posterior neck and scalp due to surgeons' unfamiliarity with the surgical anatomy and developments in free tissue transfer techniques. The goals of this study were to describe the clinical use of trapezius flaps in posterior neck and scalp reconstruction, and to investigate the vascular anatomy of trapezius flaps in Asians in order to obtain information facilitating the safe design and elevation of flaps in which most of the muscle is preserved. A retrospective chart review was performed of 10 patients who underwent trapezius muscle flap for posterior neck and scalp defects. We also performed an anatomical study of 16 flaps harvested from 8 preserved Asian adult cadavers and evaluated the main landmarks relevant for trapezius muscle flap. In the anatomical study, the mean vertical height from the inferior angle of the scapula to the point at which the superficial cervical artery penetrated the trapezius was 4.31±2.14 cm. The mean vertical height of the trapezius muscle flap pivot point was 9.53±2.08 cm from the external occipital protuberance. Among the 10 flaps, partial necrosis on the overlaid skin graft occurred in 1 patient and postoperative seroma occurred in another patient. Vascular variations in the trapezius muscle flap are uncommon in Asians, but when present, such variations appear to have little impact on harvesting the flap or on its circulation. The trapezius muscle flap is a viable alternative for posterior neck and scalp reconstruction.
Palatoplasty: suturing the mucoperiosteal flaps to the hard palate through hole.
Hwang, Kun; Lee, Ji Hun; Kim, Yu Jin; Le, Se Il
2009-05-01
We satisfactorily repaired a wide cleft palate using a method of V-Y pushback and anchoring the oral mucoperiosteal flap onto the bony ridge of the cleft. An 8-year-old Vietnamese girl had a wide incomplete bilateral posterior cleft palate associated with congenital cardiac malformations. The gap of the posterior cleft was 2.5 cm, which exceeded the total widths of the palatal shelves. We applied V-Y pushback and used a vomer flap to close the wide cleft palate. The posterior two thirds of the nasal mucosae from the cleft margins were sutured to the vomer flap. The nasal side of the anterior one third of the bony cleft was uncovered. The elevated bilateral mucoperiosteal flaps were brought together to the midline and sutured to the anterior triangular flap in a V-Y pushback fashion. Four holes were drilled 5 mm lateral to each bony cleft margin. The lateral sides of the mucoperiosteal flaps were fixed to the palate bone with 3-0 Vicryl through the hole. This method reduces the tension of the flap which might frequently cause oronasal fistula and also improve viability.
Surgical gem: island advancement flaps for lip reconstruction.
Kaufman, Andrew J
2014-08-01
Island advancement flaps provide specific advantages for repairing certain defects on the upper lip. We discuss the design and execution of this flap for defects on the alar sill and philtrum. © 2014 The Author. Australasian Journal of Dermatology © 2014 The Australasian College of Dermatologists.
A simple concept for covering pressure sores: wound edge-based propeller perforator flap.
Kelahmetoglu, Osman; Van Landuyt, Koenraad; Yagmur, Caglayan; Sommeling, Casper E; Keles, Musa K; Tayfur, Volkan; Simsek, Tekin; Demirtas, Yener; Guneren, Ethem
2017-12-01
We present a new surgical modification to allow propeller perforator flaps to cover pressure sores at various locations. We used a propeller perforator flap concept based on the detection of newly formed perforator vessels located 1 cm from the wound margin and stimulated by the chronic inflammation process. Between January 2009 and January 2017, 33 wound edge-based propeller perforator flaps were used to cover pressure sores at various locations in 28 patients. In four cases more than one flap was used on the same patient. The patients comprised 18 males and 10 females with a mean age of 41·25 (range, 16-70) years. All patients underwent follow-up for 0-12 months. The mean follow-up duration was 5·03 months. Venous congestion was observed in three flaps that were rotated by 180° (9·1%). However, there was a significant difference between flaps rotated by 90° and 180° according to the complication rate (P = 0·034). Out of 33 flaps, 29 flaps healed uneventfully. Patients were able to sit and lie on their flaps three weeks after surgery. In our study, we were able to obtain satisfying final results using these novel flaps. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Influence of two different flap designs on the sequelae of mandibular third molar surgery.
Erdogan, Ozgür; Tatlı, Ufuk; Ustün, Yakup; Damlar, Ibrahim
2011-09-01
The aim of this study was to compare the influence of triangular and envelope flaps on trismus, pain, and facial swelling after mandibular third molar surgery. Twenty healthy patients with bilateral, symmetrically impacted mandibular third molars were included in this double-blinded, prospective, cross-over, randomized study. The patients were operated with envelope flap on one side and triangular flap on the other side. Trismus was determined by measuring maximum interincisal opening, and facial swelling was evaluated using a tape measuring method. Pain was determined using visual analog scale (VAS) and recording the number of pain pills taken. The facial swelling measurements and VAS scores were lower in the envelope flap group compared to the triangular flap group. There was no significant difference between the two flap designs in operation time, maximum interincisal opening, and the number of analgesics taken. Envelope flap yields to less facial swelling and reduced VAS scores in comparison to triangular flap. There is no clinical difference in trismus between the two flap designs. Despite the higher VAS scores with triangular flap, no additional doses of analgesics were required in triangular flap.
Mechanical sensibility in free and island flaps of the foot.
Rautio, J; Kekoni, J; Hämäläinen, H; Härmä, M; Asko-Seljavaara, S
1989-04-01
Mechanical sensibility in 20 free skin flaps and four dorsalis pedis island flaps, used for the reconstruction of foot defects, was analyzed with conventional clinical methods and by determining sensibility thresholds to vibration frequencies of 20, 80, and 240 Hz. To eliminate inter-individual variability, a score was calculated for each frequency by dividing the thresholds determined for each flap with values obtained from the corresponding area on the uninjured foot. The soft tissue stability of the reconstruction was assessed. Patients were divided into three groups according to the scores. In the group of flaps with the best sensibility, the threshold increases were low at all frequencies. In the group with intermediate sensibility, the relative threshold increases were greater, the higher the frequency. In the group with the poorest sensibility, no thresholds were obtained with 240 Hz frequency and the thresholds increases were very high at all frequencies. Sensibility was not related to the length of follow-up time, nor to the type or size of the flap. However, flap sensibility was closely associated with that of the recipient area, where sensibility was usually inferior to that of normal skin. The island flaps generally had better sensibility than the free flaps. There was a good correspondence between the levels of sensibility determined by clinical and quantitative methods. The quantitative data on the level of sensibility obtained with the psychophysical method were found to be reliable and free from observer bias, and are therefore recommended for future studies. The degree of sensibility may have contributed to, but was not essential for, good soft-tissue stability of the reconstruction.
Use of Pedicled Trapezius Myocutaneous Flap for Posterior Skull Reconstruction.
Singh, Mansher; Rios Diaz, Arturo J; Cauley, Ryan; Smith, Timothy R; Caterson, E J
2015-09-01
Soft-tissue defects in posterior skull can be challenging for reconstruction. If related to tumor resection, these wound beds are generally irradiated and can be difficult from a recipient-vessel perspective for a free tissue transfer. Locoregional flaps might prove to be important reconstructive option in such patients. There is a very limited data on the usage of pedicled trapezius myocutaneous flaps for such defects. The authors reviewed existing study for usage of trapezius flap for posterior skull repair and used pedicled trapezius myocutaneous flaps based on the descending branch of superficial cervical artery (SCA) for reconstruction of posterior skull soft-tissue defect in an irradiated and infected wound. Two patients were operated for trapezius myocutaneous flap for posterior skull defects complicated by cerebrospinal fluid (CSF) leakage and epidural abscess. There was no recipient or donor-site complication at a mean follow-up of 12.5 months. Neither of the 2 patients had any functional deficits for the entire duration of the follow-up. Although this flap was able to help in controlling the CSF leakage in the first patient, it successfully healed the cavity generated from epidural abscess drainage in the second patient. The large angle of rotation coupled with the ability to complete the procedure without repositioning the patients makes trapezius myocutaneous flap an attractive option for posterior skull reconstruction. In our limited experience, the pedicled trapezius flaps are a reliable alternative as they are well vascularized and able to obliterate the soft-tissue defect completely. The recipient site healed completely in infected as well as irradiated wound beds. In addition, the donor site can be primarily closed with minimal donor-associated complication.
To flap or not to flap: continued discussion with particle image velocimetry of the near wake
NASA Astrophysics Data System (ADS)
Martin, Nathan; Roh, Chris; Idrees, Suhail; Gharib, Morteza
2017-11-01
We continue the discussion of which underwater propulsion mechanism is more effective: flapping used by fish or periodic contractions used by jellyfish. The two propulsion mechanisms are simplified into flapping and clapping plate motions, respectively, to allow for a direct comparison. A device is designed to operate in either mode of propulsion between Reynolds numbers 1,880 and 11,260, based on the average tip velocity and the span of the plate. The stroke angle, stroke time, flexibility, and duty cycle are varied to determine their impact on the generated thrust and the required torque. Overall, the clapping mode tends to require significantly more power to generate a similar thrust compared to that from the flapping mode. The performance of the clapping mode is increased by modifying the duty cycle such that the closing motion is faster than the opening motion causing a greater thrust and a similar efficiency to that from the flapping mode. Interestingly, when using rigid plates, the average thrust generated per cycle is similar between the two modes when the overall kinematics are equivalent. Investigation of the near wake of both modes through digital particle image velocimetry provides insight into the cause of this similar thrust. This work was supported by the Charyk Bio-inspired Laboratory at the California Institute of Technology, the National Science Foundation Graduate Research Fellowship under Grant No. DGE-1144469, and the Summer Undergraduate Research Fellowships program.
[Antegrade extended peroneal artery perforator flap for knee reconstruction].
Ruan, Hongjiang; Cai, Peihua; Fan, Cunyi; Chai, Yimin; Liu, Shenghe
2009-03-01
To investigate the operative technique and clinical results of repairing the soft tissue defects of knee with antegrade extended peroneal artery perforator flap. From October 2007 to January 2008, 3 patients (2 men and 1 woman) with the soft tissue defects of knee were treated, with the ages of 18, 31 and 42 years, respectively. The first case sustained femur and pelvis fractures and soft tissue defect over his right popliteal fossa, which were treated with open reduction and internal fixation (ORIF) and debridement of knee joint 2 weeks ago. The second case was necrosis of skin 3 weeks after ORIF for fracture of tibial plateau. The third case suffered from open fracture of tibial plateau and soft tissue defect, which were treated with external fixation and debridement 3 weeks ago. The defect sizes were 16 cm x 9 cm, 11 cm x 6 cm and 14 cm x 7 cm. The flap was raised by dividing the peroneal artery and veins distally and elevating them proximally, which covered for the defects of knee. The flaps were designed with the size of 18 cm x 10 cm, 12 cm 7 cm and 15 cm x 8 cm. The pure vascular pedicle of the flap was 10 cm to 17 cm in length, including the peroneal vessels and one or two perforator branches. The donor site is covered by a split thickness skin graft. All flaps survived after surgery. The donor sites healed by first intention and the skin grafts survived. After following up for 6, 8 and 11 months, the appearance and function of the flaps were all satisfactory. Based on the modified HSS knee performance system, post-operative knee functional outcomes of three patients were excellent. The antegrade extended peroneal artery perforator flap supplied by a pure vascular pedicle can be a good alternative for reconstruction of knee. The flap, with a long and thin pure vascular pedicle, could provide good texture and contour matching the recipient area.
Flap Conformations in HIV-1 Protease are Altered by Mutations
NASA Astrophysics Data System (ADS)
Fanucci, Gail; Blackburn, Mandy; Veloro, Angelo; Galiano, Luis; Fangu, Ding; Simmerling, Carlos
2009-03-01
HIV-1 protease (PR) is an enzyme that is a major drug target in the treatment of AIDS. Although the structure and function of HIV-1 PR have been studied for over 20 years, questions remain regarding the conformations and dynamics of the β-hairpin turns (flaps) that cover the active site cavity. Distance measurements with pulsed EPR spectroscopy of spin labeled constructs of HIV-1 PR have been used to characterize the flap conformations in the apo and inhibitor bound states. From the most probably distances and the breadth of the distance distribution profiles from analysis of the EPR data, insights regarding the flap conformations and flexibility are gained. The EPR results clearly show how drug pressure selected mutations alter the average conformation of the flaps and the degree of opening of the flaps. Molecular dynamics simulations successfully regenerate the experimentally determined distance distribution profiles, and more importantly, provide structural models for full interpretation of the EPR results. By combining experiment and theory to understand the role that altered flap flexibility/conformations play in the mechanism of drug resistance, key insights are gained toward the rational development of new inhibitors of this important enzyme.
Supraclavicular Artery Flap for Head and Neck Oncologic Reconstruction: An Emerging Alternative
Shenoy, Ashok; Patil, Vijayraj S.; Prithvi, B. S.; Chavan, P.; Halkud, Rajshekar
2013-01-01
Aim. Head and Neck oncologic resections often leave complex defects which are challenging to reconstruct. The need of the hour is a versatile flap which has the advantages of both a regional flap (viz. reliable and easy to harvest) and a free flap (thin, pliable with good colour match). In this a study we assessed the usefulness of the supraclavicular artery flap in head and neck oncologic defects. Materials and Method. The flap was used as a pedicled fasciocutanous and was based on the transverse supraclavicular artery. We assessed this reconstructive option for complications as well as its and functional out comes. Results. Eleven cases underwent supraclavicular artery flap between 20011-2012 of which 5 were males and 6 females. Mean defect size was 5 cm × 6 cm. Nine donor sites were closed primarily and 1 required split skin grafting. We encountered one complete flap loss which was attributed to a band of constricting skin bridge over the vascular pedicle in a defect involving lateral third of midface. Two patient developed pharyngeocutaneous fistula (without flap loss) out of 3 patients who underwent augmentation pharyngoplasty post Near total laryngectomy. Conclusion. Supra clavicular artery flap is a thin versatile, reliable, easy to harvest, with good cosmetic and functional outcome at both ends (recipient and donor) for reconstructing head and neck oncologic defects. PMID:24490064
Nasoseptal flap for palatal reconstruction after hemi-maxillectomy: case report.
Alwashahi, M K; Battaglia, P; Turri-Zanoni, M; Castelnuovo, P
2018-01-01
Palatal reconstruction following maxillectomy is a surgical challenge, and a nasoseptal flap is a feasible approach. This paper reports the first known successful clinical case of a nasoseptal pedicle flap applied for the reconstruction of maxillary bone following hemi-maxillectomy. This report describes hemi-maxillectomy in a 60-year-old Italian male diagnosed with stage IV squamous cell carcinoma of the left maxilla. Endoscopic transnasal extended medial maxillectomy was performed, followed by a transoral modified midfacial degloving technique for removal of the maxillary bone. The contralateral nasoseptal pedicle flap was used to reconstruct the defect. The case was followed up prospectively for the assessment of flap reception and healing. The locally accessible nasoseptal flap is a viable alternative for palatal reconstruction; therefore, a second surgical procedure with its associated donor site morbidity can be avoided. Large-scale studies may help in establishing the cosmetic and functional outcomes.
Geometric analysis of the V-Y advancement flap and its clinical applications.
Andrades, Patricio R; Calderon, Wilfredo; Leniz, Patricio; Bartel, German; Danilla, Stefan; Benitez, Susana
2005-05-01
Geometry is fundamental in the comprehension of local flap design. The purpose of this study was to discuss the differences between the V-Y advancement flap and other local flaps, understand its geometry, and analyze its clinical applications. The analysis was based on qualitative measurements of an injury, taking into consideration the following dimensions: largest diameter, shortest diameter, and depth. Standardization of the flap design consisted of directing its advancement over the shortest diameter and making the V base match the size of the largest diameter. The flap was analyzed in two planes: the horizontal plane includes the V-Y design and the vertical plane includes the flap pedicle. The height of the flap can be obtained by simple trigonometry, taking into consideration the largest diameter and alpha angle in the horizontal plane. In the vertical plane, where the pedicle and pivot plane are positioned, for known shortest diameter and depth, the final depth of the pivot plane can be calculated using Pythagoras' principles. This analysis was applied to 25 patients with adequate skin coverage at follow-up. A correction factor was added to reduce the overdeepening of the vertical plane calculations. The final concepts for clinical application in the classic deep pedicle V-Y flap design are to calculate the length of the V by modifying the alpha angle and to move the pivot plane deeper to accomplish optimal flap movement. Using these principles, tension-free closure of the Y and appropriate advancement of the flap are obtained.
Rotational flaps in oncologic breast surgery. Anatomical and technical considerations.
Acea Nebril, Benigno; Builes Ramírez, Sergio; García Novoa, Alejandra; Varela Lamas, Cristina
2016-01-01
Local flaps are a group of surgical procedures that can solve the thoracic closure of large defects after breast cancer surgery with low morbidity. Its use in skin necrosis complications after conservative surgery or skin sparing mastectomies facilitates the initiation of adjuvant treatments and reduces delays in this patient group. This article describes the anatomical basis for the planning of thoracic and abdominal local flaps. Also, the application of these local flaps for closing large defects in the chest and selective flaps for skin coverage by necrosis in breast conserving surgery. Copyright © 2016 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.
Yu, Shengji; Zang, Mengqing; Xu, Libin; Zhao, Zhenguo; Zhang, Xinxin; Zhu, Shan; Chen, Bo; Ding, Qiang; Liu, Yuanbo
2016-10-01
Defects after soft tissue sarcoma resection are usually managed by myocutaneous flaps or free flaps. However, harvesting muscle will cause functional morbidities, and some regions lack reliable recipient vessel. Our purpose is to use various perforator propeller flaps for oncologic reconstruction. Between 2008 and 2014, 33 perforator propeller flaps were performed in 24 patients to reconstruct the defects after tumor resection in trunk and extremities. Fifteen patients underwent tumor resection previously. Thirteen patients underwent adjuvant radiotherapy or chemotherapy. Flaps based on perforators adjacent to the lesions were raised and rotated in propeller fashion to repair the defects. Twenty-seven flaps were based on perforators of known source vessels, and 6 were harvested in freestyle fashion. The defects were repaired with 2 flaps in 4 patients and 3 flaps in 2 patients. The mean skin paddle dimension was 8.36 cm in width and 20.42 cm in length. The mean degree of flap rotation was 158.79°. Complications include partial necrosis of 6 flaps in 5 cases and venous congestion of 1 flap. In these 6 patients, 3 underwent adjuvant radiotherapy. The donor sites were primarily closed in 21 patients and skin grafted in 3 patients. No functional loss related to flap harvesting was recognized. The perforator propeller flaps can be used to manage the medium defects in extremities and large defects in torso after soft tissue sarcoma resection. They avoid the sacrifice of the underlying muscle and eliminate the concerns of the unavailability of recipient vessels. The perforator propeller flaps provide flexible options for versatile oncologic reconstruction in trunk and extremities. However, the impact of radiotherapy on the viability of the flaps for local reconstruction needs further investigation.
Flexible flapping wings with self-organized microwrinkles.
Tanaka, Hiroto; Okada, Hiroyuki; Shimasue, Yosuke; Liu, Hao
2015-06-29
Bio-inspired flapping wings with a wrinkled wing membrane were designed and fabricated. The wings consist of carbon fibre-reinforced plastic frames and a polymer film with microscale wrinkles inspired by bird feathers and the corrugations of insect wings. The flexural and tensile stiffness of the wrinkled film can be controlled by modifying the orientations and waveforms of the wrinkles, thereby expanding the design space of flexible wings for micro flapping-wing aerial robots. A self-organization phenomenon was exploited in the fabrication of the microwrinkles such that microscale wrinkles spanning a broad wing area were spontaneously created. The wavy shape of these self-organized wrinkles was used as a mould, and a Parylene film was deposited onto the mould to form a wrinkled wing film. The effect of the waveforms of the wrinkles on the film stiffness was investigated theoretically, computationally and experimentally. Compared with a flat film, the flexural stiffness was increased by two orders of magnitude, and the tensile stiffness was reduced by two orders of magnitude. To demonstrate the effect of the wrinkles on the actual deformation of the flapping wings and the resulting aerodynamic forces, the fabricated wrinkled wings were tested using a tethered electric flapping mechanism. Chordwise unidirectional wrinkles were found to prevent fluttering near the trailing edge and to produce a greater aerodynamic lift compared with a flat wing or a wing with spanwise wrinkles. Our results suggest that the fine stiffness control of the wing film that can be achieved by tuning the microwrinkles can improve the aerodynamic performance of future flapping-wing aerial robots.
Use of apron flap incision for neck dissection.
Yii, N W; Patel, S G; Williamson, P; Breach, N M
1999-05-01
Neck dissection is one of the most commonly performed surgical procedures in the management of head and neck cancer. Different skin incisions with various modifications have been described in the literature. Three commonly used but conceptually different incisions were compared with respect to the incidence of wound dehiscence in a retrospective review. There were 166 patients with 184 neck dissections carried out using a triradiate (n = 85), modified MacFee (n = 25), or an apron flap incision (n = 74). The incidence of wound dehiscence in the three groups was 11 percent, 8 percent, and 0 percent for the triradiate, modified MacFee, and apron flap incisions, respectively. There was a statistically significant difference in the incidence of wound dehiscence between the apron flap incision and the triradiate incision groups (p = 0.004). The difference in wound dehiscence was not statistically significant between the apron flap incision and the modified MacFee incision groups (p = 0.06). Overall, there was a significant increase in the incidence of wound dehiscence in previously irradiated necks (p = 0.02), but this was significant only for the triradiate incision (p = 0.005) when analyzed individually. Comparison of triradiate, apron, and MacFee incisions did not show a statistically significant difference between the incisions with regard to other postoperative complications in terms of seroma, hematoma, wound infection, and fistula formation. The apron flap incision is the recommended approach in the presence of previous neck irradiation as it gives easier access than the MacFee incision. The robustness of the flap is because of the absence of a trifurcate point as well as a good vascular supply arising from arterial territory of the external carotid artery.
Subcutaneous pedicle propeller flap: An old technique revisited and modified!
Karki, Durga; Mehta, Nikhil; Narayan, Ravi Prakash
2016-01-01
Background: Post-burn axillary and elbow scar contracture is a challenging problem to the reconstructive surgeon owing to the wide range of abduction and extension that should be achieved, respectively, while treating either of the joint. The aim of this paper is to highlight the use of subcutaneous pedicle propeller flap for the management of post-burn axillary and elbow contractures. Methodology: This is a prospective case study of axillary and elbow contractures managed at a tertiary care hospital using propeller flap based on subcutaneous pedicle from 2009 to 2014. Surgical treatment comprised of subcutaneous-based pedicle propeller flap from the normal tissue within the contracture based on central axis pedicle. The flap was rotated axially to break the contracture. The technique further encompassed a modification, a Zig-Zag incision of the flap, which was seen to prevent hypertrophy along the incision line. There was a mean period of 12 months of follow-up. Results: Thirty-eight patients consisting of 22 males and 16 females were included in this study among which 23 patients had Type II axillary contractures and 15 had moderate flexion contractures at elbow joint. The post-operative abduction achieved at shoulder joint had a mean of 168° whereas extension achieved at elbow had a mean of 175°. The functional and aesthetic results were satisfactory. Conclusion: The choice of surgical procedure for reconstruction of post-burn upper extremity contractures should be made according to the pattern of scar contracture and the state of surrounding skin. The choice of subcutaneous pedicle propeller flap should be emphasised because of the superior functional results of flap as well as ease to learn it. Moreover, the modification of propeller flap described achieves better results in terms of scar healing. There is an inter-positioning of healthy skin in between the graft, so it prevents scar band formation all around the flap. PMID:27833285
The Trapezius Muscle Flap: A Viable Alternative for Posterior Scalp and Neck Reconstruction
Yang, Hee Jun; Kim, Yang Woo; Lee, Sang Gu
2016-01-01
Background The trapezius muscle flap is not usually the first reconstructive option for skin and soft tissue defects in the posterior neck and scalp due to surgeons' unfamiliarity with the surgical anatomy and developments in free tissue transfer techniques. The goals of this study were to describe the clinical use of trapezius flaps in posterior neck and scalp reconstruction, and to investigate the vascular anatomy of trapezius flaps in Asians in order to obtain information facilitating the safe design and elevation of flaps in which most of the muscle is preserved. Methods A retrospective chart review was performed of 10 patients who underwent trapezius muscle flap for posterior neck and scalp defects. We also performed an anatomical study of 16 flaps harvested from 8 preserved Asian adult cadavers and evaluated the main landmarks relevant for trapezius muscle flap. Results In the anatomical study, the mean vertical height from the inferior angle of the scapula to the point at which the superficial cervical artery penetrated the trapezius was 4.31±2.14 cm. The mean vertical height of the trapezius muscle flap pivot point was 9.53±2.08 cm from the external occipital protuberance. Among the 10 flaps, partial necrosis on the overlaid skin graft occurred in 1 patient and postoperative seroma occurred in another patient. Conclusions Vascular variations in the trapezius muscle flap are uncommon in Asians, but when present, such variations appear to have little impact on harvesting the flap or on its circulation. The trapezius muscle flap is a viable alternative for posterior neck and scalp reconstruction. PMID:27896183
Chen, Wei-Liang; Wang, You-Yuan; Zhang, Da-Ming; Fan, Song; Lin, Zhao-Yu
2016-04-01
The purpose of this study was to compare the use of an extended vertical lower trapezius island myocutaneous flap (TIMF) and a pectoralis major myocutaneous flap (PMMF). A total of 39 patients with advanced recurrent oral and oropharyngeal squamous cell carcinoma (SCC) underwent salvage surgery followed by placement of either an extended lower vertical TIMF or PMMF for reconstruction. Twenty-one patients received extended lower vertical TIMFs, whereas 18 received PMMFs. The pedicle length of the TIMF was longer than that of the PMMF, and the skin paddle of the TIMF was both wider and longer than the PMMF. No major complication developed in any of the patients. The TIMF group experienced a lower rate of minor flap failure than did the PMMF group. Use of an extended vertical lower TIMF, which has a longer pedicle flap and a larger skin paddle than a PMMF, is optimal for reconstruction of major defects. © 2015 Wiley Periodicals, Inc. Head Neck 38: E159-E164, 2016. © 2015 Wiley Periodicals, Inc.
Turbulence Measurements on a Flap-Edge Model
NASA Technical Reports Server (NTRS)
Moriarty, Patrick; Bradshaw, Peter; Cantwell, Brian; Ross, James
1998-01-01
Turbulence measurements have been made on a flap-edge and leading-edge slat model using hot-wire anemometry, and, later, particle image velocimetry. The properties of hot-wire anemometry were studied using facilities at NASA Ames Research Center. Hot-film probes were used because of their durability, but cross-films were limited by non-linear end effects. As a warm-up exercise, hot-film probes were used to measure velocities in the farfield wake of a cylinder with an airfoil in the near-field wake. The airfoil reduced the drag coefficient of the system by 10%. A single-wire hot-film probe was used to measure velocity profiles over the top of a NACA 63(sub 2)-215 Mod. B wing with a Fowler flap and leading,-edge slat. Results showed the size of slat wake was dependent upon the slat deflection angle. Velocity increased through the slat gap with increased deflection. The acoustically modified slat decreased the chance of separation. Measurements were taken at the flap edge with a single hot-film. Trends in the data indicate velocity and turbulence levels increase at the flap edge. The acoustically modified flap modifies the mean flow near the flap edge. Correlations were made between the hot-film signal and the unsteady pressure transducers on the wing which were published in a NASA CDTM. The principles of Particle Image Velocimetry (PIV) were studied at Florida State University. Spectral PIV was used to measure the spectra of a subsonic jet. Measured frequencies were close to the predicted frequency of jet shedding. Spectral PIV will be used to measure the spectra of the slat flow in the second 7 x lO-ft. wind tunnel test. PIV has an advantage that it can measure velocity and spectra of the entire flowfield instantaneously. However, problems arise when trying, to store this massive amount of PIV data. Support for this research has continued through a NASA Graduate Student Program Fellowship which will end in June 1999. The thesis should be completed by this time.
Versatility of the Angularis Oris Axial Pattern Flap for Facial Reconstruction.
Losinski, Sara L; Stanley, Bryden J; Schallberger, Sandra P; Nelson, Laura L; Towle Millard, Heather A M
2015-11-01
To describe the versatility of the axial pattern flap based on the cutaneous perforating branch of the angularis oris artery for reconstruction of large facial defects in dogs, including complications and clinical outcomes. Retrospective clinical case series. Client-owned dogs (n = 8). Facial flaps (n = 9) based at the commissure of the lip with a caudodorsal orientation were utilized, with established anatomical borders. Flaps were elevated deep to the panniculus carnosus in a caudal to rostral direction, preserving the angularis oris artery, its cutaneous perforator, and surrounding cutaneous vasculature. Flaps were rotated dorsally or ventrally to cover the defect. Primary closure of the donor site was by direct apposition in all cases. Angularis oris axial pattern flaps were most commonly used to close large defects of the nasomaxillary area rostral to the eyes (6 dogs), followed by orbital (2) and intermandibular (1) defects. Defects occurred because of tumor resection (6 dogs), trauma (2), and a chronic, non-healing wounding (1). All flaps healed with acceptable functional and cosmetic outcomes without major complications. Followup ranged from 10 days to 16 months. Minor postoperative complications included flap edema (8 dogs), partial incisional dehiscence (3), distal tip necrosis (2), and oroantral fistula recurrence (1). Angularis oris axial pattern flaps provided hirsute, full-thickness skin coverage of a variety of large facial defects with minor complications, and should be considered when restructuring large defects of the rostral face or chin. © Copyright 2015 by The American College of Veterinary Surgeons.
[Pedicle flaps based on the sphenopalatine artery: anatomical and surgical study].
Gras-Cabrerizo, Juan R; Gras-Albert, Juan R; Monjas-Canovas, Irene; García-Garrigós, Elena; Montserrat-Gili, Joan R; Sánchez del Campo, Francisco; Kolanczak, Katarzyna; Massegur-Solench, Humbert
2014-01-01
Local pedicle flaps based on the sphenopalatine artery make it possible to reconstruct large defects of the skull base (SB). From January 2008 to January 2013, 64 lesions with involvement of SB were analysed. These lesions were treated using endoscopic endonasal approach and required a pedicle flap based on the sphenopalatine artery. In addition, measurements and flexibility of the flaps were examined in 4 cadaveric nasal cavities. Surgical group. Sixty-four nasoseptal flaps (NSF) were used, in 4 cases associated with a middle turbinate flap (MTF), and in 1 case supplemented with an inferior turbinate flap (ITF). Five cerebrospinal fluid fistulas (8%) were noted. Among patients with initial lesions, 7% presented an anosmia. Cadaveric group. The length of the NSF varied between 5.2 cm and 7.7 cm and the width ranged from 3 cm to 4.5 cm. The ITF provided an anterior-posterior distance between 4.2 cm and 5 cm, with a width between 1.2 cm and 2.8 cm. The mean length of MTFs varied between 3.5 cm and 4.2 cm, with a width between 1.4 cm and 1.9 cm. The most versatile local flap for the reconstruction of skull base defects is the NSF, and flaps pedicled to the posterolateral nasal artery offer an excellent alternative. Copyright © 2013 Elsevier España, S.L. y Sociedad Española de Otorrinolaringología y Patología Cérvico-Facial. All rights reserved.
Osteoradionecrosis of the olecranon: treatment by radial forearm flap
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thornton, J.W.; Stevenson, T.R.; VanderKolk, C.A.
1987-12-01
Osteoradionecrosis of the olecranon is an unusual pathologic entity, treated best by debridement and wound closure using vascularized tissue. Local skin is often unavailable for flap design and transposition. The radial forearm flap can be isolated on a proximal vascular pedicle and transposed to cover the wound. In the case presented, healing was brisk and complete, allowing early elbow mobilization. Although the donor site is not easily concealed, no functional impairment results from flap elevation and all full-thickness wounds are confined to the involved extremity.
14 CFR 25.701 - Flap and slat interconnection.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25... equivalent means. (b) If a wing flap or slat interconnection or equivalent means is used, it must be designed... be designed for the loads imposed when the wing flaps or slats on one side are carrying the most...
14 CFR 25.701 - Flap and slat interconnection.
Code of Federal Regulations, 2014 CFR
2014-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25... equivalent means. (b) If a wing flap or slat interconnection or equivalent means is used, it must be designed... be designed for the loads imposed when the wing flaps or slats on one side are carrying the most...
14 CFR 25.701 - Flap and slat interconnection.
Code of Federal Regulations, 2011 CFR
2011-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25... equivalent means. (b) If a wing flap or slat interconnection or equivalent means is used, it must be designed... be designed for the loads imposed when the wing flaps or slats on one side are carrying the most...
Prefabricated scalping forehead flap with skeletal support.
Fujiwara, Masao; Suzuki, Ayano; Mizukami, Takahide; Terai, Tsutomu; Fukamizu, Hidekazu
2009-07-01
It is difficult to reconstruct a nose with adequate shape, color, and texture in patients who have full-thickness nasal defects with extensive loss of skeletal support. The scalping forehead flap is a reliable technique for nasal reconstruction. To our knowledge, however, there have been no reports about a prefabricated scalping forehead flap with a bone graft as skeletal support. In the case reported here, a prefabricated scalping forehead flap combined with an iliac bone graft as skeletal support was used to successfully reconstruct a full-thickness defect of the nose associated with partial frontal bone loss and complete loss of the nasal bones. Acceptable functional and aesthetic results were achieved. This method may be a good alternative for reconstruction of full-thickness nasal defects with extensive loss of skeletal support.
Singh, G D; McNamara, J A; Lozanoff, S
1999-01-01
The purpose of this study was to assess soft tissue facial matrices in subjects of diverse ethnic origins with underlying dentoskeletal malocclusions. Pre-treatment lateral cephalographs of 71 Korean and 70 European-American children aged between 5 and 11 years with Angle's Class III malocclusions were traced, and 12 homologous, soft tissue landmarks digitized. Comparing mean Korean and European-American Class III soft tissue profiles, Procrustes analysis established statistical difference (P < 0.001) between the configurations, and this difference was also true at all seven age groups tested (P < 0.001). Comparing the overall European-American and Korean transformation, thin-plate spline analysis indicated that both affine and non-affine transformations contribute towards the total spline (deformation) of the averaged Class III soft tissue configurations. For non-affine transformations, partial warp (PW) 8 had the highest magnitude, indicating large-scale deformations visualized as labio-mental protrusion, predominantly. In addition, PW9, PW4, and PW5 also had high magnitudes, demonstrating labio-mental vertical compression and antero-posterior compression of the lower labio-mental soft tissues. Thus, Korean children with Class III malocclusions demonstrate antero-posterior and vertical deformations of the labio-mental soft tissue complex with respect to their European-American counterparts. Morphological heterogeneity of the soft tissue integument in subjects of diverse ethnic origin may obscure the underlying skeletal morphology, but the soft tissue integument appears to have minimal ontogenetic association with Class III malocclusions.
Wright, Thomas C; Mossaad, Bassem M; Chummun, Shaheel; Khan, Umraz; Chapman, Thomas W L
2013-07-01
The proximally pedicled medial plantar flap is well described for coverage of wounds around the ankle and heel. This flap is usually based on the deep venae comitantes for venous drainage, with the superficial veins divided during dissection. Usually any disruption of the deep venous system of the flap would result in abandoning this choice of flap. Venous congestion is a recognised complication of medial plantar flaps. The patient described in this case report had a medial ankle defect with exposed bone, for which a proximally pedicled medial plantar flap was used. As we raised the flap, both venae comitantes of the medial planter artery were found to be disrupted. The flap was raised based on the superficial veins draining into the great saphenous, as the only system for venous drainage, with no evidence of venous congestion. The flap was successfully transposed into the defect and healed with no complications. The proximally pedicled medial plantar flap can safely rely on the superficial venous system alone for drainage. In addition, preserving the superficial veins minimise the risk of venous congestion in this flap. We recommend preservation of superficial venous system when possible. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Orbital Floor Reconstruction with Free Flaps after Maxillectomy
Sampathirao, Leela Mohan C. S. R.; Thankappan, Krishnakumar; Duraisamy, Sriprakash; Hedne, Naveen; Sharma, Mohit; Mathew, Jimmy; Iyer, Subramania
2013-01-01
Background The purpose of this study is to evaluate the outcome of orbital floor reconstruction with free flaps after maxillectomy. Methods This was a retrospective analysis of 34 consecutive patients who underwent maxillectomy with orbital floor removal for malignancies, reconstructed with free flaps. A cross-sectional survey to assess the functional and esthetic outcome was done in 28 patients who were alive and disease-free, with a minimum of 6 months of follow-up. Results Twenty-six patients had bony reconstruction, and eight had soft tissue reconstruction. Free fibula flap was the commonest flap used (n = 14). Visual acuity was normal in 86%. Eye movements were normal in 92%. Abnormal globe position resulted in nine patients. Esthetic satisfaction was good in 19 patients (68%). Though there was no statistically significant difference in outcome of visual acuity, eye movement, and patient esthetic satisfaction between patients with bony and soft tissue reconstruction, more patients without bony reconstruction had abnormal globe position (p = 0.040). Conclusion Free tissue transfer has improved the results of orbital floor reconstruction after total maxillectomy, preserving the eye. Good functional and esthetic outcome was achieved. Though our study favors a bony orbital reconstruction, a larger study with adequate power and equal distribution of patients among the groups would be needed to determine this. Free fibula flap remains the commonest choice when a bony reconstruction is contemplated. PMID:24436744
Orbital floor reconstruction with free flaps after maxillectomy.
Sampathirao, Leela Mohan C S R; Thankappan, Krishnakumar; Duraisamy, Sriprakash; Hedne, Naveen; Sharma, Mohit; Mathew, Jimmy; Iyer, Subramania
2013-06-01
Background The purpose of this study is to evaluate the outcome of orbital floor reconstruction with free flaps after maxillectomy. Methods This was a retrospective analysis of 34 consecutive patients who underwent maxillectomy with orbital floor removal for malignancies, reconstructed with free flaps. A cross-sectional survey to assess the functional and esthetic outcome was done in 28 patients who were alive and disease-free, with a minimum of 6 months of follow-up. Results Twenty-six patients had bony reconstruction, and eight had soft tissue reconstruction. Free fibula flap was the commonest flap used (n = 14). Visual acuity was normal in 86%. Eye movements were normal in 92%. Abnormal globe position resulted in nine patients. Esthetic satisfaction was good in 19 patients (68%). Though there was no statistically significant difference in outcome of visual acuity, eye movement, and patient esthetic satisfaction between patients with bony and soft tissue reconstruction, more patients without bony reconstruction had abnormal globe position (p = 0.040). Conclusion Free tissue transfer has improved the results of orbital floor reconstruction after total maxillectomy, preserving the eye. Good functional and esthetic outcome was achieved. Though our study favors a bony orbital reconstruction, a larger study with adequate power and equal distribution of patients among the groups would be needed to determine this. Free fibula flap remains the commonest choice when a bony reconstruction is contemplated.
Mucoperiosteal Flap Necrosis after Primary Palatoplasty in Patients with Cleft Palate
Cotrina-Rabanal, Omar; Barrenechea-Tarazona, Luis; Vargas-Chanduvi, Roberto; Paredes-Aponte, Luis; Romero-Narvaez, Carolina
2017-01-01
Background The prevalence of flap necrosis after palatoplasty in patients with cleft palate. The prevalence of mucoperiosteal flap necrosis after palatoplasty remains unknown, and this complication is rare. This event is highly undesirable for both the patient and the surgeon. We present here a new scale to evaluate the degree of hypoplasia of the palate and identify patients with cleft palate at high risk for the development of this complication. Methods In this case series, a 20-year retrospective analysis (1994–2014) identified patients from our records (medical records and screening day registries) with nonsyndromic cleft palate who underwent operations at 3 centers. All of these patients underwent operations using 2-flap palatoplasty and also underwent a physical examination with photographs and documentation of the presence of palatal flap necrosis after primary palatoplasty. Results Palatal flap necrosis was observed in 4 cases out of 1,174 palatoplasties performed at these centers. The observed prevalence of palatal flap necrosis in these groups was 0.34%. Conclusions The prevalence of flap necrosis can be reduced by careful preoperative planning, and prevention is possible. The scale proposed here may help to prevent this complication; however, further studies are necessary to validate its utility. PMID:28573096
An international comparison of reimbursement for DIEAP flap breast reconstruction.
Reid, A W N; Szpalski, C; Sheppard, N N; Morrison, C M; Blondeel, P N
2015-11-01
The deep inferior epigastric artery perforator (DIEAP) flap is currently considered the gold standard for autologous breast reconstruction. With the current economic climate and health cutbacks, we decided to survey reimbursement for DIEAP flaps performed at the main international centres in order to assess whether they are funded consistently. Data were collected confidentially from the main international centres by an anonymous questionnaire. Our results illustrate the wide disparity in international DIEAP flap breast reconstruction reimbursement: a unilateral DIEAP flap performed in New York, USA, attracts €20,759, whereas the same operation in Madrid, Spain, will only be reimbursed for €300. Only 35.7% of the surgeons can set up their own fee. Moreover, 85.7% of the participants estimated that the current fees are insufficient, and most of them feel that we are evolving towards an even lower reimbursement rate. In 55.8% of the countries represented, there is no DIEAP-specific coding; in comparison, 74.4% of the represented countries have a specific coding for transverse rectus abdominis (TRAM) flaps. Finally, despite the fact that DIEAP flaps have become the gold standard for breast reconstruction, they comprise only a small percentage of all the total number of breast reconstruction procedures performed (7-15%), with the only exception being Belgium (40%). Our results demonstrate that DIEAP flap breast reconstruction is inconsistently funded. Unfortunately though, it appears that the current reimbursement offered by many countries may dissuade institutions and surgeons from offering this procedure. However, substantial evidence exists supporting the cost-effectiveness of perforator flaps for breast reconstruction, and, in our opinion, the long-term clinical benefits for our patients are so important that this investment of time and money is absolutely essential. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons
Critical assessment of the anterolateral thigh flap donor site.
Townley, W A; Royston, E C; Karmiris, N; Crick, A; Dunn, R L R
2011-12-01
The free anterolateral thigh flap (ALT) is now used as a 'workhorse flap'. The donor site morbidity is thought to be minimal, although most evidence derives from questionnaire-based studies rather than rigorous objective clinical assessment. In particular, robust quantitative data on thigh sensibility and quadriceps function is lacking. The aim of this study was to provide a comprehensive clinical assessment of donor site morbidity. We performed a prospective study of consecutive free ALT perforator flaps performed at Salisbury Foundation Trust between March 2008 and April 2010. The donor site was assessed at six months including a questionnaire (symptoms, function), scar analysis (Vancouver Scar Scale, VSS), and evaluation of quadriceps power and lateral thigh sensibility (compared with the contralateral unoperated thigh). One hundred ALT flaps were performed on 97 patients (mean age 46.8 years). The donor site was closed directly in 88 cases and using a split skin graft in 12 cases. At follow-up (n=68), tingling was the most common reported symptom (59%), whereas pain, itching and muscle herniation were reported infrequently. Donor site scars were mostly flat, pale and soft but widened. Pathological scarring was rare. Sensibility was reduced in donor thighs (p<0.001) and correlated with flap width but peak quadriceps contraction was similar between donor and unoperated thighs. There was a high throughput and diverse application of ALT flap reconstructions during the study period. Reduced sensibility was common around the scar but rarely troublesome. Quadriceps function was not affected even when dissection of intramuscular perforators was required. The ALT is a versatile flap that can deliver a large skin paddle with minimal impact on thigh function. Copyright © 2011 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Combined Direct and Indirect Cerebral Revascularization Using Local and Flow-Through Flaps.
Azadgoli, Beina; Leland, Hyuma A; Wolfswinkel, Erik M; Bakhsheshian, Joshua; Russin, Jonathan J; Carey, Joseph N
2018-02-01
Extracranial-intracranial bypass is indicated in ischemic disease such as moyamoya, certain intracranial aneurysms, and other complex neurovascular diseases. In this article, we present our series of local and flow-through flaps for cerebral revascularization as an additional tool to provide direct and indirect revascularization and/or soft tissue coverage. A retrospective review of a prospectively maintained database was performed identifying nine patients. Ten direct arterial bypass procedures with nine indirect revascularization and/or soft tissue reconstruction were performed. Indications for arterial bypass included intracranial aneurysm ( n = 2) and moyamoya disease ( n = 8). Indications for soft tissue transfer included infected cranioplasty (one) and indirect cerebral revascularization (eight). Four flow-through flaps and five pedicled flaps were used including a flow-through radial forearm fasciocutaneous flap (one), flow-through radial forearm fascial flaps (three), and pedicled temporoparietal fascial (TPF) flaps with distal end anastomosis (five). The superficial temporal vessels (seven) and facial vessels (two) were used as the vascular inflow. Arterial bypass was established into the middle cerebral artery (six) and anterior communicating artery (three). There were no intraoperative complications. All flaps survived with no donor-site complications. In one case of flow-through TPF flap, the direct graft failed, but the indirect flap remained vascularized. Local and flow-through flaps can improve combined direct and indirect revascularization and provide soft tissue reconstruction. Minimal morbidity has been encountered in early outcomes though long-term results remain under investigation for these combined neurosurgery and plastic surgery procedures. The level of evidence is IV. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Investigation of Full-Scale Split Trailing-Edge Wing Flaps with Various Chords and Hinge Locations
NASA Technical Reports Server (NTRS)
Wallace, Rudolf
1936-01-01
This report gives the results of an investigation conducted in the NACA full-scale wind tunnel on a small parasol monoplane equipped with three different split trailing-edge wing flaps. The object of the investigation was to determine and correlate data on the characteristics of the airplane and flaps as affected by variation in flap chord, flap deflection, and flap location along the wing chord. The results give the lift, the drag, and the pitching moment characteristics of the airplane, and the flap forces and moments, the pressure distribution over the flaps and wing at one section, and the downwash characteristics of the flap and wing combinations.
Plantar flaps based on perforators of the plantar metatarsal/common digital arteries.
Valentin, Georgescu Alexandru; Rodica, Matei Ileana; Manuel, Llusa
2014-09-01
Because of the unique characteristics of its integument, the affirmation "replacing like with like" becomes more than evident in the reconstruction of defects of the ultraspecialized plantar skin. But, the paucity of local resources, and especially in the forefoot, transforms this attempt in a very challenging problem. Many techniques, including skin grafts and various types of flaps were used in the management of defects in the forefoot. We present a new useful flap in the reconstruction of skin defects in the forefoot, based on small perforator vessels originating either from the plantar metatarsal arteries or plantar common digital arteries. Starting with June 2011, this flap was performed, as plantar transposition perforator flap, plantar propeller flap, or plantar propeller perforator plus flap, in seven patients with ulcers over the plantar forefoot. During a follow-up of 7 to 17 months (mean, 9.8 months), the local evolution regarding flap integration, pain, relapse, sensitive recovery, donor site, and footwear quality was analyzed. We registered a 100% survival rate of the flaps, with delayed healing in only one case. The gait resumption was possible after 6 weeks in all cases. This new flap, based on small perforator vessels from the plantar metatarsal or common digital arteries, and which provides a good, stable, and sensory recovery, seems to be a promising method in the reconstruction of plantar skin defects over the metatarsal heads. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Experimental Investigation of Aerodynamics of Feather-Covered Flapping Wing.
Yang, Wenqing; Song, Bifeng
2017-01-01
Avian flight has an outstanding performance than the manmade flapping wing MAVs. Considering that the feather is light and strong, a new type of the flapping wing was designed and made, whose skeleton is carbon fiber rods and covered by goose feathers as the skin. Its aerodynamics is tested by experiments and can be compared with conventional artificial flapping wings made of carbon fiber rods as the skeleton and polyester membrane as the skin. The results showed that the feathered wing could generate more lift than the membrane wing in the same flapping kinematics because the feathered wing can have slots between feathers in an upstroke process, which can mainly reduce the negative lift. At the same time, the power consumption also decreased significantly, due to the decrease in the fluctuating range of the periodic lift curve, which reduced the offset consumption of lift. At the same time, the thrusts generated by the feather wing and the membrane wing are similar with each other, which increases with the increase of flapping frequency. In general, the aerodynamic performances of the feather wing are superior to that of the membrane wings.
Island composite nasal flap for nasal dorsum skin defects.
Skitarelić, Neven; Mladina, Ranko; Mraovic, Boris; Simurina, Tatjana; Skitarelić, Nataa; Vuković, Katarina
2009-08-01
Skin defects on the nasal dorsum remain a challenge for the plastic surgeon. There are few local nasal flap options for the repair of proximally positioned nasal skin defects. During a 3-year period, 22 patients were treated after excision of skin cancer in the proximal two-thirds of the nose. Nine patients (41%) were female and 13 (59%) were male, with an average age of 69 years. All patients were operated on under local anesthesia. The average follow-up was 25 months. In all patients, after tumor ablation, the skin defect was closed with an island composite nasal skin flap. Pathohistologic analysis confirmed that the margins of the removed tumor were free of malignant cells. Six patients (27.3%) had squamous cell and 16 (72.7%) had basal cell carcinoma. There was no total or partial flap loss. None of the patients has suffered from recurrence of the tumor. The island composite nasal flap is a reliable technique for the closure of proximal nasal skin defects. Complications in the elevation of the island composite flap were rare, and the final result was acceptable.
Experimental Investigation of Aerodynamics of Feather-Covered Flapping Wing
Song, Bifeng
2017-01-01
Avian flight has an outstanding performance than the manmade flapping wing MAVs. Considering that the feather is light and strong, a new type of the flapping wing was designed and made, whose skeleton is carbon fiber rods and covered by goose feathers as the skin. Its aerodynamics is tested by experiments and can be compared with conventional artificial flapping wings made of carbon fiber rods as the skeleton and polyester membrane as the skin. The results showed that the feathered wing could generate more lift than the membrane wing in the same flapping kinematics because the feathered wing can have slots between feathers in an upstroke process, which can mainly reduce the negative lift. At the same time, the power consumption also decreased significantly, due to the decrease in the fluctuating range of the periodic lift curve, which reduced the offset consumption of lift. At the same time, the thrusts generated by the feather wing and the membrane wing are similar with each other, which increases with the increase of flapping frequency. In general, the aerodynamic performances of the feather wing are superior to that of the membrane wings. PMID:29527117
Dual-dermal-barrier fashion flaps for the treatment of sacral pressure sores.
Hsiao, Yen-Chang; Chuang, Shiow-Shuh
2015-02-01
The sacral region is one of the most vulnerable sites for the development of pressure sores. Even when surgical reconstruction is performed, there is a high chance of recurrence. Therefore, the concept of dual-dermal-barrier fashion flaps for sacral pressure sore reconstruction was proposed. From September 2007 to June 2010, nine patients with grade IV sacral pressures were enrolled. Four patients received bilateral myocutaneous V-Y flaps, four patients received bilateral fasciocutaneous V-Y flaps, and one patient received bilateral rotation-advanced flaps for sacral pressure reconstruction. The flaps were designed based on the perforators of the superior gluteal artery in one patient's reconstructive procedure. All flaps' designs were based on dual-dermal-barrier fashion. The mean follow-up time was 16 months (range = 12-25). No recurrence was noted. Only one patient had a complication of mild dehiscence at the middle suture line, occurring 2 weeks after the reconstructive surgery. The dual-dermal fashion flaps are easily duplicated and versatile. The study has shown minimal morbidity and a reasonable outcome.
Role of Square Flap in Post Burn Axillary Contractures.
Karki, Durga; Narayan, Ravi Prakash
2017-09-01
Post-burn contractures are a commonly encountered problem and many techniques have been described in their treatment. Z-plasties are the commonest local flap procedure done for linear bands with adjacent healthy tissue. Our aim was to assess the use of square flap technique in axillary contractures. Ten patients with type I and II axillary contractures underwent release by the square flap technique. All cases were followed up for at least one year and analysed for range of motion and aesthetic outcome. All cases achieved full range of movement postoperatively with no recurrence during follow up period and a good cosmetic outcome. Square flap was shown to be a reliable technique for mild to moderate axillary contractures of the anterior or posterior axillary folds even when there is significant adjacent scarring of chest wall or back of types I and II.
Transfer of free fillet lateral arm flap for facial reconstruction.
Bayram, Fazli Cengiz; Dadaci, Mehmet; Ince, Bilsev; Altuntas, Zeynep
2014-07-01
We describe a 16-year-old male patient who had a major right facial degloving injury resulting in a soft-tissue defect with exposed zygoma as well as temporal and frontal bones. Multiple operations were undertaken in a staged manner for reconstruction. Lateral arm free fillet flap transfer was initially performed with fixation of bones with miniplates, which is followed by flap debulking, lateral canthopexy, scalp tissue expansion for hairline reconstruction, as well as ear reconstruction with costal cartilage and local flap techniques. After a follow-up period of 2 years, a good and impressive reconstructive result was achieved through the use of multiple contemporary reconstructive procedures after a successful free fillet flap transfer from an amputated part.
Lower lip reconstruction with nasolabial flap--going back to basics.
Coutinho, Inês; Ramos, Leonor; Gameiro, Ana Rita; Vieira, Ricardo; Figueiredo, Américo
2015-01-01
Squamous cell carcinoma of the lower lip is frequent, and radical excision sometimes leads to complex defects. Many lip repair techniques are aggressive requiring general anesthesia and a prolonged post-operative period. The nasolabial flap, while a common flap for the repair of other facial defects, is an under-recognized option for the reconstruction of the lower lip. We describe the use of nasolabial flap for the repair of a large defect of the lower lip in a ninety year-old male, with good functional results and acceptable cosmetic outcome. We believe the nasolabial flap is a good alternative for intermediate-to-large lower lip defects in patients with impaired general condition.
Reconstruction of palatal defect using mucoperiosteal hinge flap and pushback palatoplasty.
Lee, S I; Lee, H S; Hwang, K
2001-11-01
This article describes a simple, new surgical technique to provide a complete two-layer closure of palatal defect resulting from a surgical complication of trans palatal resection of skull base chordoma. The nasal layer was reconstructed with triangular shape oral mucoperiosteal turn over hinge flap based on anterior margin of palatal defect and rectangular shaped lateral nasal mucosal hinge flaps. The oral layer was reconstructed with conventional pushback V-Y advancement 2-flaps palatoplasty. Each layer of the flaps were secured with two key mattress suture for flap coaptation. This technique has some advantages: simple, short operation time, one-stage procedure, no need of osteotomy. It can close small- to medium-sized palatal defect of palate or wide cleft palate and can prevent common complication of oronasal fistula, which could be caused by tension.
Central artery perforator propeller flap for nasal and medial canthal defects.
Baltu, Yahya; Uzun, Hakan; Dölen, Utku Can; Özyurtlu, Mustafa
2016-08-01
Non-melanoma skin cancer is the most common type of skin cancer of the nasal dorsum and the medial canthal region, which is caused by chronic sun exposure. Limited adjacent tissue and the need for aesthetically pleasing result make the reconstruction of these regions very challenging. To overcome this challenge, we designed a perforator propeller flap based on the central artery. Between January 2014 and November 2015, we covered the nasal or medial canthal defects of 22 patients with central artery perforator propeller flaps. The mean age of the patients was 60.4 years (range: 47-81 years). The median follow-up period was 7.5 months (range: 2-23 months). The pathological diagnoses were basal cell carcinoma for 14 patients and squamous cell carcinoma for the remaining eight patients. The size of the defects ranged from 2 × 2 to 3.5 × 4 cm, and that of the flaps ranged from 2 × 3.5 to 3.2 × 6 cm. We did not observe any major complications requiring surgery, such as total flap loss, hematoma, or dog-ear deformity. However, venous congestion was seen in five patients and partial flap necrosis (that healed without intervention) in two patients. The central artery perforator propeller flap is a reliable and versatile flap for the reconstruction of the nasal dorsum and medial canthal region. Reconstruction with this flap is a single-stage procedure that can cover large defects without causing dog-ear deformity or eyebrow asymmetry compared with other local flap options. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Airfoil-Wake Modification with Gurney Flap at Low Reynolds Number
NASA Astrophysics Data System (ADS)
Gopalakrishnan Meena, Muralikrishnan; Taira, Kunihiko; Asai, Keisuke
2018-04-01
The complex wake modifications produced by a Gurney flap on symmetric NACA airfoils at low Reynolds number are investigated. Two-dimensional incompressible flows over NACA 0000 (flat plate), 0006, 0012 and 0018 airfoils at a Reynolds number of $Re = 1000$ are analyzed numerically to examine the flow modifications generated by the flaps for achieving lift enhancement. While high lift can be attained by the Gurney flap on airfoils at high angles of attack, highly unsteady nature of the aerodynamic forces are also observed. Analysis of the wake structures along with the lift spectra reveals four characteristic wake modes (steady, 2S, P and 2P), influencing the aerodynamic performance. The effects of the flap over wide range of angles of attack and flap heights are considered to identify the occurrence of these wake modes, and are encapsulated in a wake classification diagram. Companion three-dimensional simulations are also performed to examine the influence of three-dimensionality on the wake regimes. The spanwise instabilities that appear for higher angles of attack are found to suppress the emergence of the 2P mode. The use of the wake classification diagram as a guidance for Gurney flap selection at different operating conditions to achieve the required aerodynamic performance is discussed.
Nasolabial Perforator Flap for One-stage Reconstruction of Nasal Defects
Prakash, Siddharth; Panda, Ritesh; Kumar, Vivek; Saha, Shiv Shankar; Choudhary, Lalit; Pandey, Anurag; Reddy, J. Sasidhar
2017-01-01
Background: The excellent freedom of movement and range of this flap when based on a the nasolabial perforator flap have not been sufficiently explored. In this study, along with demonstrating the other key advantages of this flap over its traditional counterpart, we will endeavour to fill these lacunae in the available literature. Materials and Methods: From February 2009 to February 2012, twenty patients with nasal defects were repaired with a nasolabial perforator flap in the Department of Plastic and Cosmetic Surgery at Sir Ganga Ram Hospital, New Delhi. Of these, two patients (10%) underwent the procedure bilaterally. Thus, a total of 22 nasolabial perforator flap procedures were carried out. Prospectively, collected clinical records and data of each patient were retrospectively retrieved and reviewed to study the nasal defect and surgery done. Results: All the twenty (100%) patients had good functional and aesthetic outcome. All patients who had nasal stenosis preoperatively had very good improvement in the patency of the nasal passages, breathing and nasal blockage with complete recovery of symptoms. The patients were entirely satisfied with the functional recovery. Conclusions: The reliability and versatility of the nasolabial perforator flap exceed its recognised application in reconstruction of nasal defects and it must form a part of every plastic surgeon's armamentarium. PMID:28529417
Blade-mounted trailing edge flap control for BVI noise reduction
NASA Technical Reports Server (NTRS)
Hassan, A. A.; Charles, B. D.; Tadghighi, H.; Sankar, L. N.
1992-01-01
Numerical procedures based on the 2-D and 3-D full potential equations and the 2-D Navier-Stokes equations were developed to study the effects of leading and trailing edge flap motions on the aerodynamics of parallel airfoil-vortex interactions and on the aerodynamics and acoustics of the more general self-generated rotor blade vortex interactions (BVI). For subcritical interactions, the 2-D results indicate that the trailing edge flap can be used to alleviate the impulsive loads experienced by the airfoil. For supercritical interactions, the results show the necessity of using a leading edge flap, rather than a trailing edge flap, to alleviate the interaction. Results for various time dependent flap motions and their effect on the predicted temporal sectional loads, differential pressures, and the free vortex trajectories are presented. For the OLS model rotor, contours of a BVI noise metric were used to quantify the effects of the trailing edge flap on the size and directivity of the high/low intensity noise region(s). Average reductions in the BVI noise levels on the order of 5 dB with moderate power penalties on the order of 18 pct. for a four bladed rotor and 58 pct. for a two bladed rotor were obtained.
Reverse saphenous conduit flap in small animals: Clinical applications and outcomes.
Elliott, Ross C
2014-08-20
Due to the lack of skin elasticity defects of the distal hind limb can be a challenge to close. This article assesses a well-described, but completely under-used technique for closure of wounds on the distal tarsus. The technique was used with good success in six cases presenting to the Bryanston Veterinary Hospital with a wide range of underlying pathology ranging from trauma to neoplastic disease of the tarsus. All six cases were treated with a reverse saphenous conduit flap and two of them underwent radiation therapy with no adverse side effects. All cases showed excellent results with a very low degree of flap necrosis that never exceeded 15% of the total flap area. This skin flap provides an excellent treatment method that is reliable in closure of defects of the distal tarsus with few adverse effects. To the author's knowledge there has been only one previously published report on the clinical use of this type of skin flap, even though the flap is well described in most texts.
1987-05-01
flaps were mosL vulnerable to necrosis . Sutures placed with minimal tension did not adversely affect blood perfusion of surgically replaced flaps. vi * C...perfusion change with narrow flaps most severely affected. In general, narrow thin flaps were most vulnerable to necrosis . Sutures placed with minimal...Day Narrow Pedicle ............. 75 B. Fluorescein Angiography of Envelope Flap Immediately Post Surgery and Necrosis of Marginal Third of Six
Kang, Jin Seok; Choi, Hwan Jun; Tak, Min Sung
2016-06-01
Free flaps are still the gold standard for large defects of the lower limb, but propeller perforator flaps have become a simpler and faster alternative to free flaps because of some advantages such as reliable vascular pedicle, wide mobilization and rotation, great freedom in design, low donor site morbidity, and easy harvest with no requirement for anastomosis. But when the vessels show insufficient findings in preoperative evaluation using a Doppler probe or the vessel is injured, the surgeon should avoid performing free flap surgery to prevent flap failure and should select a propeller perforator flap as an alternative method on the condition that more than one perforator is intact. In this study, we report reconstruction of soft tissue defects of the heel with a pedicled propeller flap in postfasciotomy and popliteal artery revascularization state by making an incision on the central portion above the Achilles tendon, which can be covered by the posterior tibial artery perforator or the peroneal artery perforator based flaps. In conclusion, we showed that although the popliteal artery was injured, the soft tissue defect can be reconstructed using a perforator propeller flap if intact distal flow in the anastomosis site was confirmed. © The Author(s) 2015.
Mallet, Cindy; Ilharreborde, Brice; Jehanno, Pascal; Litzelmann, Estelle; Valenti, Philippe; Mazda, Keyvan; Penneçot, Georges-François; Fitoussi, Franck
2013-03-01
Many commissural reconstruction techniques have been described for the treatment of syndactyly. This study is the first to compare long-term results of 2 commissural dorsal flap procedures (T-flap and omega-flap). Fifty-nine web-spaces in 39 patients, operated on between 1991 and 2008, were retrospectively analyzed. Thirty-six T-flap and 23 omega-flap procedures were performed using full-thickness skin graft in every case for digital resurfacing. Factors that could affect the long-term outcome were collected, including development of web-creep, clinodactyly, and flexion contracture. Patients were reviewed with a mean follow-up of 5 years and 8 months. Preoperative complexity of syndactyly influenced the development of clinodactyly and flexion contracture. Among the patients who developed clinodactyly, 96% had surgery for complex syndactyly. No difference was found between the 2 flap methods concerning digital deformation and mobility. However, web-creep occurred more frequently after T-flap than after omega-flap procedures (17% vs. 5%). The combination of either dorsal commissural T-flaps or omega-flaps with full-thickness graft to resurface digits is a reliable technique for the treatment of syndactyly with satisfactory functional and cosmetic results. Long-term results are not influenced by the type of flap. Nevertheless, the omega-flap technique, using 2 triangular lateral-palmar flaps, avoids use of skin graft to cover lateral-palmar aspects of the new commissure, consequently reducing the incidence of web-creep. In cases of syndactyly, the primary prognostic factor is whether the patient has simple or complex syndactyly. In complex syndactyly, the risk of long-term unfavorable results is higher. When complex complicated syndactyly is involved, postoperative complication rates increase. Level III.
NASA Astrophysics Data System (ADS)
Viswamurthy, S. R.; Ganguli, Ranjan
2007-03-01
This study aims to determine optimal locations of dual trailing-edge flaps to achieve minimum hub vibration levels in a helicopter, while incurring low penalty in terms of required trailing-edge flap control power. An aeroelastic analysis based on finite elements in space and time is used in conjunction with an optimal control algorithm to determine the flap time history for vibration minimization. The reduced hub vibration levels and required flap control power (due to flap motion) are the two objectives considered in this study and the flap locations along the blade are the design variables. It is found that second order polynomial response surfaces based on the central composite design of the theory of design of experiments describe both objectives adequately. Numerical studies for a four-bladed hingeless rotor show that both objectives are more sensitive to outboard flap location compared to the inboard flap location by an order of magnitude. Optimization results show a disjoint Pareto surface between the two objectives. Two interesting design points are obtained. The first design gives 77 percent vibration reduction from baseline conditions (no flap motion) with a 7 percent increase in flap power compared to the initial design. The second design yields 70 percent reduction in hub vibration with a 27 percent reduction in flap power from the initial design.
Local Vascularized Flaps for Augmentation of Reinke’s Space
Dailey, Seth H.; Gunderson, McLean; Chan, Roger; Torrealba, Jose; Kimura, Miwako; Welham, Nathan V.
2011-01-01
Objectives/Hypothesis The purpose of this study is to describe and test a novel surgical strategy for augmentation of Reinke’s space using vascularized flaps: a thyroid ala perichondrium flap (TAP) and a composite thyroid ala perichondrium flap (CTAP) from the anterior larynx. We hypothesized that these specially designed vascularized flaps would remain viable once inset into the lamina propria, and that they would not disrupt rheologic, biomechanical, and histologic properties of the native vocal fold. Study Design Experimental. In vivo canine model. Methods The length and volume of test flaps harvested in six adult human cadaveric larynges were analyzed to determine suitability for use in augmentation in the lamina propria. Also, 12 beagles randomly underwent unilateral placement of either TAP or CTAP, which were designed in accordance with the human adult cadaveric experiments. Flap perfusion was measured before and after harvest with laser Doppler. After 1 month, the beagles were humanely sacrificed and their larynges subjected to aerodynamic and acoustic evaluation using an excised larynx apparatus. The vocal fold lamina propria of four larynges—two TAP and two CTAP—underwent rheologic evaluation using a simple-shear rheometer. The remaining eight larynges underwent quantitative histologic and immunohistochemical evaluation. The survival and complication (swallowing, airway, local wound) rates of all dogs were noted. Results Initial studies with adult human cadaveric larynges established that TAP and CTAP possessed length and volume greater than native lamina propria. In the canine experiments, the perfusion change in the flaps was similar between flap groups. The damping ratio (ζ), dynamic viscosity (η′), elastic shear modulus (G′), and viscous shear modulus (G″) of treated and untreated native vocal folds were not statistically different. The glottic function measures of vocal efficiency, laryngeal resistance, jitter, shimmer, and harmonics
Availability of the lateral calcaneal region as a donor site of free flaps.
Cho, Seung Woo; Park, Ji Ung; Kwon, Sung Tack
2017-09-01
Various methods have been used for the coverage of soft-tissue defects, such as local and free flaps, as well as perforator flaps performed using even supermicrosurgery. However, the techniques have some limitations regarding flap size and location when used to reconstruct small defects. We introduced the lateral calcaneal region as a donor site for free flaps in order to overcome these disadvantages and presented the results from a series of cases. A retrospective chart review was performed on 10 patients with small soft-tissue defects who underwent reconstruction with a lateral calcaneal free flap between January 2011 and May 2014. The reconstruction was performed on the defects at medial and lateral plantar area, dorsum of the foot, great toes and preauricular area. The size of the flaps ranged from 2.5 × 2.5 cm to 4.5 × 4.5 cm. The flaps exhibited complete survival in five cases. Partial necrosis occurred in three cases, two cases healed with secondary intention, and one case required a skin graft. The donor sites were treated with skin grafts and healed completely, with no complications. Lateral calcaneal free flaps have several advantages, such as anatomically constant pedicles, a pliable and thin texture, and the ability to be used as sensory flaps. They therefore represent an alternative option when conventional local or free flaps are not suitable, especially in cases of small defects. © 2016 Wiley Periodicals, Inc. Microsurgery 37:494-501, 2017. © 2016 Wiley Periodicals, Inc.
[Perineal reconstruction: Salvage surgery with 2flaps technique].
Jiménez Gómez, Marta; Navarro-Sánchez, Antonio; Lima Sánchez, Jaime; Hernández Hernández, Juan Ramón
2017-12-01
The principles of perineal reconstructive surgery comprise adequate filling of the defect along with stable and durable skin coverage, with a low morbidity rate. Two-flap perineal reconstruction is a simple, fast and reliable technique that uses a single donor site. This improves scar position with low morbidity. It is based in the use of 2flaps; one flap fills the defect with a «turn over» technique and the other is a rotation - advancement flap for skin coverage. A 52-year-old male diagnosed with Lynch syndrome who underwent laparoscopic abdominoperineal amputation for adenocarcinoma of the lower rectum and developed recurrence 2years later over the perineal scar that required radical resection and perineal reconstruction. The use of this approach facilitates perineal reconstruction and enables treatment of patients with large and complex defects in frequently irradiated tissues where wound dehiscence and infection are common. Copyright © 2017 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.
The 'RITE' use of the Fricke flap in periorbital reconstruction.
Wilcsek, G; Leatherbarrow, B; Halliwell, M; Francis, I
2005-08-01
To revisit an important but outmoded periorbital reconstructive technique. We present cases to illustrate the usefulness of the Fricke flap and describe a method of rapid intraoperative tissue expansion (RITE), which can enhance the applicability and effectiveness of the Fricke flap. A comparison between those cases performed with and without adjunctive RITE was not made due to the low numbers available. A retrospective review of clinical cases. A total of 20 cases in which the Fricke flap was used for periorbital reconstruction were reviewed. The mean patient age was 64.7 years; the male-to-female ratio was 1:1. The patient follow-up ranged from 1 to 8 years with a mean of 4.2 years. The most common cause (65%) of periorbital defect was excision of eyelid malignancy. Necrosis of the terminal segment of the flap requiring further surgical intervention occurred in 10% (2/20). In both of these cases, the surgeons were trainees, with the complications being due to poor surgical technique. In the first case, the flap base was too narrow and in the second case, the distal end of the flap was thinned excessively. The functional result was excellent in 10/20 (50%), good in 5/20 (25%), fair in 3/20 (15%), and poor in 2/20 (10%). The cosmetic result was excellent in 3/20 (15%), good in 12/20 (60%), fair in 3/20 (15%), and poor in 2/20 (10%). The Fricke flap is an important and, in selected cases, an indispensable technique in periorbital reconstruction.
Nickl, Stefanie; Nedomansky, Jakob; Radtke, Christine; Haslik, Werner; Schroegendorfer, Klaus F
2018-01-31
The transverse myocutaneous gracilis (TMG) flap is a widely used alternative to abdominal flaps in autologous breast reconstruction. However, secondary procedures for aesthetic refinement are frequently necessary. Herein, we present our experience with an optimized approach in TMG breast reconstruction to enhance aesthetic outcome and to reduce the need for secondary refinements. We retrospectively analyzed 37 immediate or delayed reconstructions with TMG flaps in 34 women, performed between 2009 and 2015. Four patients (5 flaps) constituted the conventional group (non-optimized approach). Thirty patients (32 flaps; modified group) underwent an optimized procedure consisting of modified flap harvesting and shaping techniques and methods utilized to reduce denting after rib resection and to diminish donor site morbidity. Statistically significant fewer secondary procedures (0.6 ± 0.9 versus 4.8 ± 2.2; P < .001) and fewer trips to the OR (0.4 ± 0.7 versus 2.3 ± 1.0 times; P = .001) for aesthetic refinement were needed in the modified group as compared to the conventional group. In the modified group, 4 patients (13.3%) required refinement of the reconstructed breast, 7 patients (23.3%) underwent mastopexy/mammoplasty or lipofilling of the contralateral breast, and 4 patients (13.3%) required refinement of the contralateral thigh. Total flap loss did not occur in any patient. Revision surgery was needed once. Compared to the conventional group, enhanced aesthetic results with consecutive reduction of secondary refinements could be achieved when using our modified flap harvesting and shaping techniques, as well as our methods for reducing contour deformities after rib resection and for overcoming donor site morbidities. © 2017 Wiley Periodicals, Inc.
[Reconstruction of ankle and foot with combination of free perforator flaps and skin graft].
Yin, Lu; Gong, Ketong; Yin, Zhonggang; Zhang, Bo; Xu, Jianhua
2017-03-01
To evaluate the clinical outcomes of free perforator flaps combined with skin graft for reconstruction of ankle and foot soft tissue defects. Between June 2014 and October 2015, 20 cases of ankle and foot soft tissue defects were treated. There were 16 males and 4 females, aged from 19 to 61 years (mean, 43.3 years). Injury was caused by traffic accident in 7 cases, by crashing in 9 cases, and machine twist in 4 cases. The locations were the ankle in 6 cases, the heel in 3 cases, the dorsum pedis in 4 cases, and the plantar forefoot in 7 cases of avulsion injury after toes amputation. The size of wound ranged from 15 cm×10 cm to 27 cm×18 cm. The time from injury to treatment was from 11 to 52 days (mean, 27 days). The anterolateral thigh perforator flap was used in 11 cases, thoracodorsal antery perforator flap in 3 cases, medial sural artery perforator flap in 4 cases, deep inferior epigastric perforator flap in 1 case, and anteromedial thigh perforator flap in 1 case, including 5 chimeric perforator flaps, 5 polyfoliate perforator flaps, 3 flow-through perforator flaps, and 3 conjoined perforator flaps. The size of the perforator flap ranged from 10.0 cm×6.5 cm to 36.0 cm×8.0 cm, the size of skin graft from 5 cm×3 cm to 18 cm×12 cm. Venous crisis occurred in 2 flaps which survived after symptomatic treatment; 18 flaps survived successfully and skin grafting healed well. The follow-up time ranged 4-18 months (mean, 8.3 months). The flaps had good appearance, texture and color, without infection. The patients could walk normally and do daily activities. Only linear scars were observed at the donor sites. Free perforator flap can be used to reconstruct defects in the ankle and foot, especially in the weight-bearing area of the plantar forefoot. A combination of free perforator flap and skin graft is ideal in reconstruction of great soft tissue defects in the ankle and foot.
Investigation of leading-edge flap performance on delta and double-delta wings at supersonic speeds
NASA Technical Reports Server (NTRS)
Covell, Peter F.; Wood, Richard M.; Miller, David S.
1987-01-01
An investigation of the aerodynamic performance of leading-edge flaps on three clipped delta and three clipped double-delta wing planforms with aspect ratios of 1.75, 2.11, and 2.50 was conducted in the Langley Unitary Plan Wind Tunnel at Mach numbers of 1.60, 1.90, and 2.16. A primary set of fullspan leading-edge flaps with similar root and tip chords were investigated on each wing, and several alternate flap planforms were investigated on the aspect-ratio-1.75 wings. All leading-edge flap geometries were effective in reducing the drag at lifting conditions over the range of wing aspect ratios and Mach numbers tested. Application of a primary flap resulted in better flap performance with the double-delta planform than with the delta planform. The primary flap geometry generally yielded better performance than the alternate flap geometries tested. Trim drag due to flap-induced pitching moments was found to reduce the leading-edge flap performance more for the delta planform than for the double-delta planform. Flow-visualization techniques showed that leading-edge flap deflection reduces crossflow shock-induced separation effects. Finally, it was found that modified linear theory consistently predicts only the effects of leading-edge flap deflection as related to pitching moment and lift trends.
Cryptotia correction--the post-auricular transposition flap.
Marsh, D; Sabbagh, W; Gault, D
2011-11-01
Cryptotia is a congenital ear deformity in which the upper pole appears buried beneath mastoid skin. Here we describe our method of cryptotia correction which we have used to good effect with minimal complications. 20 patients and 24 ears were operated on. All surgery was performed by the senior authors WS and DG. Patient age range was 4-19 years and mean follow up was 2.1 years. We use a superiorly based V-shaped flap raised from the post-auricular skin. Following ear release, the flap is rotated into the defect and donor site closed directly. Our technique ensures all scars are hidden behind the ear, there are no skin grafts required. All patients had a satisfactory release of cryptotia, there were no cases of partial or total flap failure, none of wound dehiscence and no patients required revisional surgery. The post-auricular flap is a simple technique, retaining the depth of the auriculotemporal sulcus, providing a good skin colour match without the need for skin grafting and without distorting the hair line. Our results are comparable or superior to those seen with other techniques previously described. Copyright © 2011 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Li, Yiyuan; Zhang, Ruhong; Zhang, Qun; Xu, Zhicheng; Xu, Feng; Li, Datao
2017-02-01
Advances in staged total auricular reconstruction have resulted in improved anterior auricular appearance; however, satisfactory postreconstruction esthetics of the retroauricular fold remain challenging. The postauricular appearance of the reconstructed ear depends largely upon optimizing the covering material. When used as the covering soft tissue for ear elevation, a flap containing primarily the upper portion of the retroauricular fascia has potential advantages over the conventional book cover-type retroauricular fascia flap. We developed a geometrically designed, posterosuperior auricular fascia flap to replace the conventional retroauricular fascia flap for ear elevation. During the second-stage operation, the posterosuperior auricular fascia flap is rotated downward and turned over to wrap around the inner strut and entire posterior auricular surface. Compared to the conventional book cover-type retroauricular fascia flap, the novel posterosuperior auricular fascia flap was easier to harvest and the operative time significantly decreased (110.3 vs. 121.5 min, p < 0.01). The modified flap produced a thin and natural contour of the postauricular surface, as well as reduced the incidence of postauricular hypertrophic scarring (from 24.7 to 13.2%, p = 0.03) and partial skin graft necrosis (from 43.4 to 31.2%, p = 0.01). The geometrically designed posterosuperior auricular fascia flap improves ear elevation. Compared to the conventional book cover-type retroauricular fascia flap, this covering tissue is easier to perform so the surgical time is decreased. It was highly vascularized, well defined, thinner, and yields reliable results. Thus, favorable postauricular surface results can be achieved during auricular reconstruction by using the modified fascia flap. This journal requires that authors assign a level of evidence to each submission to which Evidence-Based Medicine rankings are applicable. This excludes Review Articles, Book Reviews, and
Preoperative TRAM free flap volume estimation for breast reconstruction in lean patients.
Minn, Kyung Won; Hong, Ki Yong; Lee, Sang Woo
2010-04-01
To obtain pleasing symmetry in breast reconstruction with transverse rectus abdominis myocutaneous (TRAM) free flap, a large amount of abdominal flap is elevated and remnant tissue is trimmed in most cases. However, elevation of abundant abdominal flap can cause excessive tension in donor site closure and increase the possibility of hypertrophic scarring especially in lean patients. The TRAM flap was divided into 4 zones in routine manner; the depth and dimension of the 4 zones were obtained using ultrasound and AutoCAD (Autodesk Inc., San Rafael, CA), respectively. The acquired numbers were then multiplied to obtain an estimate of volume of each zone and the each zone volume was added. To confirm the relation between the estimated volume and the actual volume, authors compared intraoperative actual TRAM flap volumes with preoperative estimated volumes in 30 consecutive TRAM free flap breast reconstructions. The estimated volumes and the actual elevated volumes of flap were found to be correlated by regression analysis (r = 0.9258, P < 0.01). According to this result, we could confirm the reliability of the preoperative volume estimation using our method. Afterward, the authors applied this method to 7 lean patients by estimation and revision of the design and obtained symmetric results with minimal donor site morbidity. Preoperative estimation of TRAM flap volume with ultrasound and AutoCAD (Autodesk Inc.) allow the authors to attain the precise volume desired for elevation. This method provides advantages in terms of minimal flap trimming, easier closure of donor sites, reduced scar widening and symmetry, especially in lean patients.
Technique and outcomes of laparoscopic bulge repair after abdominal free flap reconstruction.
Lee, Johnson C; Whipple, Lauren A; Binetti, Brian; Singh, T Paul; Agag, Richard
2016-01-21
Bulges and hernias after abdominal free flap surgery are uncommon with rates ranging from as low as 0-36%. In the free flap breast reconstruction population, there are no clear guidelines or optimal strategies to treating postoperative bulges. We describe our minimally invasive technique and outcomes in managing bulge complications in abdominal free flap breast reconstruction patients. A retrospective review was performed on all abdominal free flap breast reconstruction patients at Albany Medical Center from 2011 to 2014. All patients with bulges on clinical exam underwent abdominal CT imaging prior to consultation with a minimally invasive surgeon. Confirmed symptomatic bulges were repaired laparoscopically and patients were monitored regularly in the outpatient setting. Sixty-two patients received a total of 80 abdominal free flap breast reconstructions. Flap types included 41 deep inferior epigastric perforator (DIEP), 36 muscle-sparing transverse rectus abdominus myocutaneous (msTRAM), 2 superficial inferior epigastric artery, and 1 transverse rectus abdominus myocutaneous flap. There were a total of 9 (14.5%) bulge complications, with the majority of patients having undergone msTRAM or DIEP reconstruction. There were no complications, revisions, or recurrences from laparoscopic bulge repair after an average follow-up of 181 days. Although uncommon, bulge formation after abdominal free flap reconstruction can create significant morbidity to patients. Laproscopic hernia repair using composite mesh underlay offers an alternative to traditional open hernia repair and can be successfully used to minimize scarring, infection, and pain to free flap patients who have already undergone significant reconstructive procedures. © 2016 Wiley Periodicals, Inc. Microsurgery, 2016. © 2016 Wiley Periodicals, Inc.
Ottria, L; Luciani, F; Piva, P; Alagna, A M; Arcuri, C; Bartuli, F N
2017-01-01
The purpose of the study was to analyze the healing of the deep and superficial lower first and second molars periodontium, after the surgical extraction of the contiguous impacted third molar, comparing 3 mucoperiosteal flap designs. 150 patients which had to undergo a impacted lower third molar surgery were enrolled in this study. They were checked from day 0 to day 90, in order to focus on the recovery quality of the soft tissues around the lower second molar, comparing 3 different flap designs. No intraoperatory incident happened. The complete recovery of the periodontium around the second molar has been shown in each patient after 90 days from surgery and each adverse reaction happened within the sixth week after surgery. Only 2 slight gengival recessions 0,5 mm have been find out. The impacted third molar surgery is an operation that, if rightly programmed and performed, is relatively safe. Besides, the correct handling and management of periodontium around the second molar and the choice of the flap type to be used support a correct recovery on the second molar periodontium, avoiding any long-term damage. This study wanted to analyze the healing of the deep and superficial lower second molar periodontium, after the impacted lower third molar surgery. In order to improve the surgical technique used for lower third molar germectomies, we wanted to compare 3 different kind of flap designs.
A Comparative Study of Simulated and Measured Gear-Flap Flow Interaction
NASA Technical Reports Server (NTRS)
Khorrami, Mehdi R.; Mineck, Raymond E.; Yao, Chungsheng; Jenkins, Luther N.; Fares, Ehab
2015-01-01
The ability of two CFD solvers to accurately characterize the transient, complex, interacting flowfield asso-ciated with a realistic gear-flap configuration is assessed via comparison of simulated flow with experimental measurements. The simulated results, obtained with NASA's FUN3D and Exa's PowerFLOW® for a high-fidelity, 18% scale semi-span model of a Gulfstream aircraft in landing configuration (39 deg flap deflection, main landing gear on and off) are compared to two-dimensional and stereo particle image velocimetry measurements taken within the gear-flap flow interaction region during wind tunnel tests of the model. As part of the bench-marking process, direct comparisons of the mean and fluctuating velocity fields are presented in the form of planar contour plots and extracted line profiles at measurement planes in various orientations stationed in the main gear wake. The measurement planes in the vicinity of the flap side edge and downstream of the flap trailing edge are used to highlight the effects of gear presence on tip vortex development and the ability of the computational tools to accurately capture such effects. The present study indicates that both computed datasets contain enough detail to construct a relatively accurate depiction of gear-flap flow interaction. Such a finding increases confidence in using the simulated volumetric flow solutions to examine the behavior of pertinent aer-odynamic mechanisms within the gear-flap interaction zone.
Prophylactic flap coverage and the incidence of bronchopleural fistulae after pneumonectomy
Llewellyn-Bennett, Rebecca; Wotton, Robin; West, Douglas
2013-01-01
A best evidence topic in thoracic surgery was written according to a structured protocol. The question addressed was ‘In pneumonectomy patients, is buttressing the bronchial stump associated with a reduced incidence of bronchopleural fistula?’. Fifty-seven papers were found using the reported search, of which 12 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. One prospective randomized controlled trial was identified, which found significantly lower rates of bronchopleural fistula and empyema after pneumonectomy with the use of pedicled intercostal flap buttressing. Intercostal muscle flaps and pericardial flaps have been used in case series of high-risk patients, e.g. those with neoadjuvant therapy or extended resections, with low rates of subsequent bronchopleural fistulae. There is the least-reported evidence for thoracodorsal artery perforator and omental flaps. There is relatively little published evidence beyond the single randomized trial identified, with only a few comparison studies to guide clinicians. We conclude that there is evidence for flap buttressing in reducing the risk of bronchopleural fistulae after pneumonectomy in diabetic patients. Flap coverage in other high-risk situations, such as extrapleural or completion pneumonectomy, has been reported in case series with good results. Of the reported techniques, the evidence is strongest for the pedicled inter-costal flap. PMID:23357525
An experimental study of pressures on 60 deg Delta wings with leading edge vortex flaps
NASA Technical Reports Server (NTRS)
Marchman, J. F., III; Terry, J. E.; Donatelli, D. A.
1983-01-01
An experimental study was conducted in the Virginia Tech Stability Wind Tunnel to determine surface pressures over a 60 deg sweep delta wing with three vortex flap designs. Extensive pressure data was collected to provide a base data set for comparison with computational design codes and to allow a better understanding of the flow over vortex flaps. The results indicated that vortex flaps can be designed which will contain the leading edge vortex with no spillage onto the wing upper surface. However, the tests also showed that flaps designed without accounting for flap thickness will not be optimum and the result can be oversized flaps, early flap vortex reattachment and a second separation and vortex at the wing/flap hinge line.
[Contribution of the scrotal flap for the coverage of ischial and perineal pressure ulcers].
Vantomme, M; Viard, R; Aimard, R; Vincent, P-L; Comparin, J-P; Voulliaume, D
2018-04-11
The ischiatric pressure sore is a common pathology in rehabilitated spinal cord injured people, despite careful prevention. Medical treatment by discharge and directed healing is not always sufficient and surgery using local musculocutaneous flaps is often essential. Unfortunately, recidivism is frequent and the availability of local flaps is limited. The scrotal flap is an excellent complement to classic flaps, gluteal flaps or hamstrings. It can be used alone or in addition to another musculocutaneous flap, in first or second intention. The scrotal flap is a musculocutaneous flap, using the Dartos, the platys muscle of the scrotum. It is richly vascularized, extensible and resistant. Its great plasticity makes it adaptable to any form of loss of substance, with an arc of rotation that can reach the anal margin. It can also be desepidermized and buried to fill a deep defect. Ten cases of scrotal flaps and their different indications are reviewed: some are used in first intention, others in addition to musculocutaneous flaps. The removal of a scrotal flap is fast and extremely easy. The simple closure of the donor site allows the sampling of half of the scrotum due to the great local laxity. The scrotal flaps achieved quickly healed, as well as the donor sites. Only one recurrence was observed after an inappropriate treatment of underlying osteitis. No complications have occurred. The scrotal musculocutaneous flap, reliable, resistant, quick and easy to remove is an excellent means of coverage of the perineal region. It can be used for the treatment of any loss of perineal substance in humans, but remains particularly useful for the treatment of ischial or perineal pressure sores. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
A histopathological study of bulbar conjunctival flaps occurring in 2 contact lens wearers.
Markoulli, Maria; Francis, Ian C; Yong, Jim; Jalbert, Isabelle; Carnt, Nicole; Cole, Nerida; Papas, Eric
2011-09-01
To study the histopathology of paralimbal bulbar conjunctival flaps occurring secondary to soft contact lens wear. Slit-lamp biomicroscopy using sodium fluorescein, cobalt blue light, and a Wratten filter was used to observe the presence, location, and dimensions of bulbar conjunctival flaps presenting in a cohort of contact lens wearers. Two subjects who exhibited such flaps agreed to undergo conjunctival biopsy. Tissue samples, obtained from the region of the flap, and an adjacent unaffected area were processed by standard histopathological methods. In the first subject, analysis of the flap tissue showed even collagen distribution and overall normal histology. The flap of the second subject displayed a mild focal increase in collagen and mild degeneration of collagen, but no increase in elastic tissue. Conjunctival epithelium was normal in both cases. In these 2 subjects, conjunctival flap tissue either was normal or showed only minimal abnormality. There is insufficient evidence for significant pathological change on the time scale of this study.
Vertical Profunda Artery Perforator Flap for Plantar Foot Wound Closure: A New Application.
Alfonso, Allyson R; Mayo, James L; Sharma, Vishal K; Allen, Robert J; Chiu, Ernest S
2018-02-01
Plantar foot reconstruction requires special consideration of both form and function. There are several fasciocutaneous flap options, each with indications and reservations. This case presents a new application of the vertical profunda artery perforator flap for definitive closure of a neuropathic foot ulcer in a young woman with spina bifida. The postoperative course was uneventful, and the flap survived completely. The surgical and donor sites were without wound recurrence at 5-month follow-up. Understanding the variability of foot flap options is important because of unique cases such as the one presented where the wound was caused by specific and less commonly observed foot anatomy. The specific choice to use the vertical profunda artery perforator flap for this patient and her neuropathic wound type was made based on its excellent flexibility, durability, and donor site appeal. The vertical profunda artery perforator flap has adequate surface area and bulk and a favorable pedicle length and caliber, can be thinned, and leaves a donor scar in a less conspicuous area than other popular free flaps for lower-extremity reconstruction. For these reasons, it should be considered a first-line therapy for free flap coverage of selected foot wounds.
Patel, Urjeet A; Hernandez, David; Shnayder, Yelizaveta; Wax, Mark K; Hanasono, Matthew M; Hornig, Joshua; Ghanem, Tamer A; Old, Matthew; Jackson, Ryan S; Ledgerwood, Levi G; Pipkorn, Patrik; Lin, Lawrence; Ong, Adrian; Greene, Joshua B; Bekeny, James; Yiu, Yin; Noureldine, Salem; Li, David X; Fontanarosa, Joel; Greenbaum, Evan; Richmon, Jeremy D
2017-08-01
Free flap reconstruction of the head and neck is routinely performed with success rates around 94% to 99% at most institutions. Despite experience and meticulous technique, there is a small but recognized risk of partial or total flap loss in the postoperative setting. Historically, most microvascular surgeons involve resident house staff in flap monitoring protocols, and programs relied heavily on in-house resident physicians to assure timely intervention for compromised flaps. In 2003, the Accreditation Council for Graduate Medical Education mandated the reduction in the hours a resident could work within a given week. At many institutions this new era of restricted resident duty hours reshaped the protocols used for flap monitoring to adapt to a system with reduced resident labor. To characterize various techniques and frequencies of free flap monitoring by nurses and resident physicians; and to determine if adapted resident monitoring frequency is associated with flap compromise and outcome. This multi-institutional retrospective review included patients undergoing free flap reconstruction to the head and/or neck between January 2005 and January 2015. Consecutive patients were included from different academic institutions or tertiary referral centers to reflect evolving practices. Technique, frequency, and personnel for flap monitoring; flap complications; and flap success. Overall, 1085 patients (343 women [32%] and 742 men [78%]) from 9 institutions were included. Most patients were placed in the intensive care unit postoperatively (n = 790 [73%]), while the remaining were placed in intermediate care (n = 201 [19%]) or in the surgical ward (n = 94 [7%]). Nurses monitored flaps every hour (q1h) for all patients. Frequency of resident monitoring varied, with 635 patients monitored every 4 hours (q4h), 146 monitored every 8 hours (q8h), and 304 monitored every 12 hours (q12h). Monitoring techniques included physical examination (n = 949 [87
Hu, Melissa; Ludlow, David; Alexander, J Steven; McLarty, Jerry; Lian, Timothy
2014-03-01
To determine if the intravascular delivery of mesenchymal stem cells improves wound healing and blood perfusion to postischemic cutaneous flap tissues. Randomized controlled study. A murine model of a cutaneous flap was created based on the inferior epigastric vessels. Mice (n = 14) underwent 3.5 hours of ischemia followed by reperfusion. Bone marrow stromal cells (BMSCs) 1 × 10(6) were injected intravenously. Wound healing was then assessed measuring percent flap necrosis, flap perfusion, and tensile strength of the flap after a period of 14 days. Localization of BMSCs was determined with radiolabeled and fluorescent labeled BMSCs. Postischemic cutaneous flap tissues treated with BMSCs demonstrated significantly less necrosis than control flaps (P <0.01). Beginning on postoperative day 5, BMSC-treated flaps demonstrated greater blood perfusion than untreated flaps (P <0.01). Tensile strength of BMSC-treated cutaneous flaps was significantly higher (P <0.01), with a mean strength of 283.4 ± 28.4 N/m than control flaps with a mean of 122.4 ± 23.5 N/m. Radiolabeled BMSCs localized to postischemic flaps compared to untreated tissues (P = 0.001). Fluorescent microscopy revealed incorporation of BMSCs into endothelial and epithelial tissues of postischemic flaps. This study demonstrates that the intravascular delivery of BMSCs increases wound healing and promotes flap survival following ischemia-reperfusion injury of cutaneous tissue flaps. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.
Aerodynamics of high frequency flapping wings
NASA Astrophysics Data System (ADS)
Hu, Zheng; Roll, Jesse; Cheng, Bo; Deng, Xinyan
2010-11-01
We investigated the aerodynamic performance of high frequency flapping wings using a 2.5 gram robotic insect mechanism developed in our lab. The mechanism flaps up to 65Hz with a pair of man-made wing mounted with 10cm wingtip-to-wingtip span. The mean aerodynamic lift force was measured by a lever platform, and the flow velocity and vorticity were measured using a stereo DPIV system in the frontal, parasagittal, and horizontal planes. Both near field (leading edge vortex) and far field flow (induced flow) were measured with instantaneous and phase-averaged results. Systematic experiments were performed on the man-made wings, cicada and hawk moth wings due to their similar size, frequency and Reynolds number. For insect wings, we used both dry and freshly-cut wings. The aerodynamic force increase with flapping frequency and the man-made wing generates more than 4 grams of lift at 35Hz with 3 volt input. Here we present the experimental results and the major differences in their aerodynamic performances.
The revascularization of pedicle skin flaps in pigs: a functional and morphologic study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Young, C.M.
1982-10-01
Functional and morphologic changes occurring during the revascularization of pedicle flaps have been investigated in the skin of pigs. The skin flaps, 16 cm long by 4 cm wide, were based on a row of segmental vessels arising from the internal mammary artery. Comparative measurements were made in flapped and normal skin. The inherent blood supply in the pedicle of the flap was unable to maintain the whole of the flap in a viable state. Flap viability was ascertained at surgery by the use of the intravital dye Disulphine blue. Injections of the dye after surgery gave a less accuratemore » prediction of viability than when dye was injected prior to surgery. Revascularization between the flap and surrounding skin was evident 3 to 4 days postoperatively at the distal, most hypoxic part of the viable flap. The whole flap had a collateral vascular supply 7 to 10 days after surgery. Isotope clearance studies showed that the greatest functional changes occurred in the distal third of the viable flap, where, after initially slowing, the clearance rate became faster than in normal skin (day 5). Potassium extraction studies indicated similar changes. However, an increase in the red-cell volume on day 1 suggested that vascular shunting was occurring. The results of the morphologic studies indicated a correlation between the number of blood vessels per unit area, the thickness of the dermis, and the recorded functional changes. Seven days after surgery, when isotope clearance rates were very rapid, there was a significant increase in the vascular density and dermal thickness.« less
Influence of minoxidil on ischemic cutaneous flaps in rats.
Bittencourt, Rogério de Castro; Biondo-Simões, Maria de Lourdes Pessole; Paula, Josué Brunginski de; Martynetz, Juliano; Groth, Anne
2005-01-01
To evaluate the influence of minoxidil, a well known vasodilator, on ischemic flap necrosis prevention in rats. Ventral cutaneous flaps, measuring 8x4 cm, were designed in 20 Wistar rats based on the right cranial epigastric artery. In the experiment group, 50 mg/kg/day of minoxidil sulfate was administered by orogastric tube and the same amount of saline solution was administered to the control group. Such procedure was initiated 24 h before surgery and kept once a day through the 7th postoperative day. Microcirculation was evaluated with laser fluxometry 24 h before surgical procedure, at immediate postoperative and at the 7th postoperative day. Flap necrosis area was evaluated by 2 methods: planimetry and weight/paper ratio. A significant flow increase in distal and medial extremity at M1 (medial point 1) (p=0.0484) was observed in the experiment group. There was significant difference in flap necrosis prevention in the experiment group (p=0.0433), although after necrosis took place there was no significant difference in necrosis size. (p=0.1051 and p=0.2799). Minoxidil sulfate is effective in avoiding necrosis in ischemic flaps, but after necrosis is present there is no difference in survival area between experimental and control groups.
Pressure investigation of NASA leading edge vortex flaps on a 60 deg Delta wing
NASA Technical Reports Server (NTRS)
Marchman, J. F., III; Donatelli, D. A.; Terry, J. E.
1983-01-01
Pressure distributions on a 60 deg Delta Wing with NASA designed leading edge vortex flaps (LEVF) were found in order to provide more pressure data for LEVF and to help verify NASA computer codes used in designing these flaps. These flaps were intended to be optimized designs based on these computer codes. However, the pressure distributions show that the flaps wre not optimum for the size and deflection specified. A second drag-producing vortex forming over the wing indicated that the flap was too large for the specified deflection. Also, it became apparent that flap thickness has a possible effect on the reattachment location of the vortex. Research is continuing to determine proper flap size and deflection relationships that provide well-behaved flowfields and acceptable hinge-moment characteristics.
Lifting-surface theory for calculating the loading induced on a wing by a flap
NASA Technical Reports Server (NTRS)
Johnson, W. A.
1972-01-01
A method is described for using lifting-surface theory to obtain the pressure distribution on a wing with a trailing-edge flap or control surface. The loading has a logarithmic singularity at the flap edges, which may be determined directly by the method of matched asymptotic expansions. Expressions are given for the singular flap loading for various flap hinge line and side edge geometries, both for steady and unsteady flap deflection. The regular part of the flap loading must be obtained by inverting the lifting-surface-theory integral equation relating the pressure and the downwash on the wing: procedures are described to accomplish this for a general wing and flap geometry. The method is applied to several example wings, and the results are compared with experimental data. Theory and test correlate well.
Experimental validation of a true-scale morphing flap for large civil aircraft applications
NASA Astrophysics Data System (ADS)
Pecora, R.; Amoroso, F.; Arena, M.; Noviello, M. C.; Rea, F.
2017-04-01
Within the framework of the JTI-Clean Sky (CS) project, and during the first phase of the Low Noise Configuration Domain of the Green Regional Aircraft - Integrated Technological Demonstration (GRA-ITD, the preliminary design and technological demonstration of a novel wing flap architecture were addressed. Research activities were carried out to substantiate the feasibility of morphing concepts enabling flap camber variation in compliance with the demanding safety requirements applicable to the next generation green regional aircraft, 130- seats with open rotor configuration. The driving motivation for the investigation on such a technology was found in the opportunity to replace a conventional double slotted flap with a single slotted camber-morphing flap assuring similar high lift performances -in terms of maximum attainable lift coefficient and stall angle- while lowering emitted noise and system complexity. Studies and tests were limited to a portion of the flap element obtained by slicing the actual flap geometry with two cutting planes distant 0.8 meters along the wing span. Further activities were then addressed in order to increase the TRL of the validated architecture within the second phase of the CS-GRA. Relying upon the already assessed concept, an innovative and more advanced flap device was designed in order to enable two different morphing modes on the basis of the A/C flight condition / flap setting: Mode1, Overall camber morphing to enhance high-lift performances during take-off and landing (flap deployed); Mode2, Tab-like morphing mode. Upwards and downwards deflection of the flap tip during cruise (flap stowed) for load control at high speed. A true-scale segment of the outer wing flap (4 meters span with a mean chord of 0.9 meters) was selected as investigation domain for the new architecture in order to duly face the challenges posed by real wing installation. Advanced and innovative solutions for the adaptive structure, actuation and control
Treatment of ischial pressure sores using a modified gracilis myofasciocutaneous flap.
Lin, Haodong; Hou, Chunlin; Chen, Aimin; Xu, Zhen
2010-04-01
Despite the availability of a variety of flap reconstruction options, ischial pressure sores continue to be the most difficult pressure sores to treat. This article describes a successful surgical procedure for the coverage of ischial ulcers using a modified gracilis myofasciocutaneous flap. From August 2000 to April 2004, 12 patients with ischial sores were enrolled in the study. All patients underwent early aggressive surgical debridement followed by surgical reconstruction with a modified gracilis myofasciocutaneous flap. The follow-up period ranged from 13 to 86 months, with a mean of 44 months. Overall, 91.7% of the flaps (11 of 12) survived primarily. Partial flap necrosis occurred in one patient. Primary wound healing occurred without complications at both the donor and recipient sites in all cases. In one patient, grade II ischial pressure sores recurred 13 months after the operation. There was no recurrence in other 11 patients. A modified gracilis myofasciocutaneous flap provides a good cover for ischial pressure sores. Because it is easy to use and has favorable results, it can be used in the primary treatment for large and deep ischial pressure sores. Copyright Thieme Medical Publishers.
Zeltzer, Assaf A; Anzarut, Alexander; Braeckmans, Delphine; Seidenstuecker, Katrin; Hendrickx, Benoit; Van Hedent, Eddy; Hamdi, Moustapha
2017-09-01
A growing number of surgeons perform lymph node transfers for the treatment of lymphedema. When harvesting a vascularized lymph node groin flap (VGLNF) one of the major concerns is the potential risk of iatrogenic lymphedema of the donor-site. This article helps understanding of the lymph node distribution of the groin in order to minimize this risk. Fifty consecutive patients undergoing abdominal mapping by multi-detector CT scanner were included and 100 groins analyzed. The groin was divided in three zones (of which zone II is the safe zone) and lymph nodes were counted and mapped with their distances to anatomic landmarks. Further node units were plotted and counted. The average age was 48 years. A mean number of nodes of 6.5/groin was found. In zone II, which is our zone of interest a mean of 3.1 nodes were counted with a mean size of 7.8 mm. In three patients no nodes were found in zone II. In five patients nodes were seen in zone II but were not sufficient in size or number to be considered a lymph node unit. On average the lymph node unit in zone II was found to be 48.3 mm from the pubic tubercle when projected on a line from the pubic tubercle to the anterior superior iliac spine, 16.0 mm caudal to this line, and 20.4 mm above the groin crease. On average the lymph node unit was a mean of 41.7 mm lateral to the SCIV-SIEV confluence. This study provides increased understanding of the lymphatic anatomy in zone II of the groin flap and suggests a refined technique for designing the VGLNF. As with any flap there is a degree of individual patient variability. However, having information on the most common anatomy and flap design is of great value. © 2017 Wiley Periodicals, Inc.
Reconstruction of posterior neck and skull with vertical trapezius musculocutaneous flap
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mathes, S.J.; Stevenson, T.R.
1988-10-01
The vertical trapezius musculocutaneous flap has been successfully utilized for reconstruction in 13 patients with complex posterior skull and neck defects. This flap based on its vascular pedicle, the descending branch of the transverse cervical artery, provides well-vascularized tissue for coverage of defects related to chronic osteomyelitis, tumor extirpation, osteoradionecrosis, and dehisced cervical laminectomy wounds. Emphasis on flap design, including the location of the skin island, allows adequate wound coverage, direct donor site closure, and muscle function preservation. With its large size and wide arc of rotation, the vertical trapezius musculocutaneous flap provides reliable coverage for posterior trunk, cervical, andmore » skull defects.« less
Chaput, B; Gandolfi, S; Ho Quoc, C; Chavoin, J-P; Garrido, I; Grolleau, J-L
2014-02-01
In recent years, perforator flaps have become an indispensable tool for the reconstruction process. Most recently, "propeller" perforator flaps allow each perforator vessels to become a flap donor site. Once the perforator of interest is identified by acoustic Doppler, the cutaneous or fascio-cutaneous island is designed and then customized according to the principle of "perforasome". So, the flap can be rotated such a propeller, up to 180°. Ideally the donor site is self-closing, otherwise it can be grafted at the same time. Through a skin necrosis secondary to a contrast medium extravasation of the cubital fossa in a 47-year-old man, we describe the use of propeller perforator flap based on a perforator of the radial collateral artery (RCAP). The perforator was identified preoperatively by acoustic Doppler then the flap was adapted bespoke to cover the loss of substance. Ultimately, the result was very satisfying. Well experienced for lower-extremity reconstruction, perforator-based propeller flap are still few reported for upper limb. It is likely that in the future, propeller flap supersede in many indication not only free flaps and locoregional flaps but also, leaving no room for uncertainties of the vascular network, the classic random flaps. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
[Soft tissue defects treated with perforator flaps].
Weum, Sven; de Weerd, Louis; Klein, Steven; Hage, J Joris
2008-01-31
Treatment of soft tissue defects caused by trauma, tumour surgery or pressure sores is a challenge to the reconstructive surgeon. Although contour and function may be restored by tissue transposition, traditional methods often cause significant donor site morbidity. This article describes how increased understanding of vascular anatomy has led to the development of new techniques. The article is based on textbooks of plastic surgery, selected articles and own clinical experience. Pedicled and free perforator flaps represent the latest development in surgical treatment of soft tissue defects. The use of perforator flaps can considerably reduce the disadvantages that are associated with other surgical methods. The use of perforator flaps demands microsurgical skills, but has many advantages. Reliable vascular supply and a good aesthetical result can be combined with minimal donor site morbidity. In many cases this technique may even give sensibility to the reconstructed area.
Modified trans-oral approach with an inferiorly based flap.
Al-Holou, Wajd N; Park, Paul; Wang, Anthony C; Than, Khoi D; Marentette, Lawrence J
2010-04-01
The trans-oral approach allows direct access to pathologies of the anterior craniocervical junction. However, the classic midline incision of the posterior pharyngeal wall can be surgically burdensome and limits lateral exposure. We reviewed the medical records of nine patients undergoing the trans-oral approach. The sites of the pathology ranged from the clivus to C2, and surgical exposure ranged from the clivus to C3. Each operation utilized an inferiorly based flap. None of the patients experienced vascular or neurologic complications, and no patient had a cerebrospinal fluid fistula, pseudomeningocele, or meningitis postoperatively. The trans-oral approach with an inferiorly based flap can therefore be safely and effectively performed with minimal oropharyngeal and neurologic morbidity. Not only does a U-shaped flap allow adequate exposure from the lower half of the clivus to C3, a flap improves lateral exposure, provides a clear operating field, and allows superficial mucosal closure not directly overlying the operative field. (c) 2009 Elsevier Ltd. All rights reserved.
Breast oedema following free flap breast reconstruction.
Greenhowe, Jennifer; Stephen, Christopher; McClymont, Liusaidh; Munnoch, D Alex
2017-08-01
Breast oedema causes significant morbidity and is historically difficult to quantify. The aim of this study was to identify changes in breast tissue water content from pre-operative levels in the native breast to post-operative levels in mastectomy skin flaps and free flaps in the reconstructed breast. One hundred patients undergoing unilateral mastectomy and immediate free flap breast reconstruction were examined pre-operatively and at three post-operative appointments. A validated moisture meter was used to record dermal water percentages of each breast quadrant and areola in both breasts pre-operatively, then four quadrants of both breasts plus the unaffected areola and free flap at each post-operative review. Native skin of the reconstructed breast showed significant, persistent increase in MWC from 45.6% ± 0.5% to 72.8% ± 0.9% at 1st follow up (p < 0.001), decreasing only to 67.6% ± 0.8% by 3rd follow up. There was a marked difference (p < 0.001) in the mean water content (MWC) of the initial free flap (39.7% ± 0.6%) compared to 61.8% ± 1.7% at 1st follow up, then 55.1% ± 1.4% at 2nd and 53.7% ± 1.3% at 3rd follow ups. The unaffected breast showed a small but significant increase in MWC of all quadrants at subsequent follow up (greatest difference 3.1% at 1st follow up). This patient group demonstrates significant, persistent oedema of the reconstructed breast, which can be monitored using a non-invasive moisture meter. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.
[Application and development of free composite tissue flap in plastic surgery].
Lu, Kaihua; Han, Yan; Guo, Shuzhong
2007-09-01
To summarize and review the development and experience of anastomosis vascular pedicle free composite tissue flap. From July 1987 to March 2007, 321 patients with complete records were treated. Fourteen tissue flaps were applied for the repair of trauma or tumor excision defects of the body, and for organ reconstruction. Vascular crisis occurred in 20 patients within 48 hours postoperatively. Necrosis occurred at flap end in 6 patients. The total survival rate was 94.8%. The main experience was: (1) Training to grasp the basic micro-vascular anastomosis technique was very important starting up period for surgeons. The basic technique should be often practiced to ensure the safty of clinical application. (2) Restoring appearance and function were equally important in practice. (3) Utilizing the minimal invasive methods and decreasing the loss of function of donor site were important for improvement of reconstruction quality. The purpose was to achieve functional and esthetic restoration in the condition of lowest donor site scarification. The application of free composite tissue flap is important for the development of plastic surgery. There are extensive applications for free flap, especially for those critical patients. The application of free flap could decrease the mobility rate, shorten the treatment period, ease the pain of patients and improve the reconstruction effect. The experience of donor site selection, the strategy of poor recipient site condition, the advantages and disadvantages of muscle flap, the applications time, infections wound treatment and application, are helpful for the future application.
Lower extremity soft tissue reconstruction with free flap based on subscapular artery.
Karşıdağ, Semra; Akçal, Arzu; Turgut, Gürsel; Uğurlu, Kemal; Baş, Lütfü
2011-01-01
The purpose of our study was to evaluate the results of the reconstruction of the lower extremity defects with free flaps based on the subscapular artery. Between January, 1998 and December, 2008, 51 patients (mean age 26 years; 16 female and 35 male) presenting with a lower extremity defect underwent a reconstructive surgery with flaps based on the subscapular vascular system. Thirty-seven percent of the defects were located in the crus, 19% in the sole, 16% in the heel, and 14% in the dorsum of the foot. Eighty and a half percent of the patients had traffic-accident-related and 13.5% had burn-related tissue defects. Fifty-three percent of the patients presenting with lower extremity defects underwent reconstruction with latissimus dorsi muscle flaps, 21% with free serratus muscle and/or fascia flaps, 14% with free parascapular fasciocutaneous flaps, and 12% with free combined latissimus muscle and serratus muscle and/or fascia flaps. Anastomoses of 80% of the patients were performed on their posterior tibial artery and accompanying veins and/or foot dorsal veins. End-to-end anastomosis was performed on 14 patients, while 35 patients received end-to-side anastomosis. Six patients were treated with cross free flaps, of which 4 received cross latissimus, 1 cross serratus, and 1 cross combined serratus and latissimus flaps. End-to-side anastomoses were performed on these patients on the cross-leg tibialis posterior artery. The cross-leg anastomosis was freed 4 weeks later. In the early period, venous occlusion was observed in 4 patients and arterial and venous occlusion was present in 1 patient. New anastomoses were performed in these patients. Partial necrosis was observed in 2 patients. The average follow-up period was 61 months. Pressure-related late ulcerative lesions developed in 4 patients. The lesions of these patients were repaired by debridement and primary suturing or partial thickness skin grafts. The subscapular vascular system based flaps have an optimal
Complications of femtosecond-assisted laser in-situ keratomileusis flaps.
Shah, Deepika N; Melki, Samir
2014-01-01
Femtosecond-assisted laser in-situ keratomileusis flaps have revolutionized refractive surgery since their introduction. Although these lasers are exceedingly safe, complications still do occur. This review focuses specifically on examining the literature and evidence for flap complications during femtosecond-assisted laser in-situ keratomileusis as well as their management.
Free anterolateral thigh flap for reconstruction of car tire injuries of children's feet.
Demirtas, Yener; Neimetzade, Tale; Kelahmetoglu, Osman; Guneren, Ethem
2010-01-01
Grade IV and V car tire injuries occurring in children cause extensive soft tissue defects with exposure or loss of tendons and bone on the dorsum of the foot. Free tissue transfer is indicated for reconstruction of these defects because of the limited local tissue available. We describe our management of high-grade car tire foot injuries in children with free anterolateral thigh flap (ALT). Five pre-school children with car tire injuries (one grade IV and four grade V) were treated with free ALT flap in the last 4 years. The mean age was 4.8 years. In four patients, immediate flap coverage after initial debridement was performed and delayed reconstruction was used as a secondary procedure in one patient. One of the flaps was re-explored for hematoma evacuation and salvaged. All of the flaps survived completely and there were no donor site complications. None of the flaps required a debulking procedure and custom shoe wear has not been necessary in any of the patients. Minor gait abnormalities were detected in two of the patients. With minimal donor site morbidity, long vascular pedicle allowing anastomosis outside of the trauma zone, we believe free ALT flap provides the ideal soft tissue reconstruction for high grade car tire injuries of foot in children. ALT flap can be further thinned to adapt to the defect, contracts less than muscle flaps and contains a vascularized fascia which can be used for extensor tendon reconstruction.
The complicated role of venous drainage on the survival of arterialized venous flaps
Weng, Weidong; Zhang, Feng; Zhao, Bin; Wu, Zhipeng; Gao, Weiyang; Li, Zhijie; Yan, Hede
2017-01-01
The arterialized venous flap (AVF) has been gradually popularized in clinical settings; however, its survival is still inconsistent and the role of venous drainage remains elusive. In this study, we aimed to investigate the role of venous drainage on the flap survival of arterialized venous flaps. An arterialized venous flap was outlined symmetrically in the rabbit abdomen. The arterial perfusion flap with a unilateral vascular pedicle was taken as the control group and three other experimental groups (I, II and III) were designed based on the number of drainage veins (n = 1, 2 and 3 in the three groups, respectively). Compared with the control group, significant venous congestion was noted in all the experimental groups and the most severe one was seen in group I; while no statistical difference was observed between groups II and III. Similar results regarding blood perfusion state, epidermal metabolite levels and flap survival status were obtained among the three groups. These findings suggested that venous drainage is vital in the survival of the flap, but unlike in the arterial perfusion flaps, the problem of venous congestion can only be partially solved by increasing the number of draining veins. Further studies are warranted to gain insight into this complicated issue. PMID:28145882
Wake Measurement Downstream of a Hybrid Wing Body Model with Blown Flaps
NASA Technical Reports Server (NTRS)
Lin, John C.; Jones, Gregory S.; Allan, Brian G.; Westra, Bryan W.; Collins, Scott W.; Zeune, Cale H.
2010-01-01
Flow-field measurements were obtained in the wake of a full-span Hybrid Wing Body model with internally blown flaps. The test was performed at the NASA Langley 14 x 22 Foot Subsonic Tunnel at low speeds. Off-body measurements were obtained with a 7-hole probe rake survey system. Three model configurations were investigated. At 0deg angle of attack the surveys were completed with 0deg and 60deg flap deflections. At 10deg angle of attack the wake surveys were completed with a slat and a 60deg flap deflection. The 7-hole probe results further quantified two known swirling regions (downstream of the outboard flap edge and the inboard/outboard flap juncture) for the 60deg flap cases with blowing. Flowfield results and the general trends are very similar for the two blowing cases at nozzle pressure ratios of 1.37 and 1.56. High downwash velocities correlated with the enhanced lift for the 60deg flap cases with blowing. Jet-induced effects are the largest at the most inboard station for all (three) velocity components due in part to the larger inboard slot height. The experimental data are being used to improve computational tools for high-lift wings with integrated powered-lift technologies.
Saçak, Bülent; Yalçın, Doğuş; Pilancı, Özgür; Tuncer, Fatma Betül; Çelebiler, Özhan
2017-01-01
Background The effect of liposuction on the perforators of the lower abdominal wall has been investigated in several studies. There are controversial results in the literature that have primarily demonstrated the number and patency of the perforators. The aim of this study was to determine the effect of liposuction on the perfusion of perforator-based abdominal flaps using a combined laser–Doppler spectrophotometer (O2C, Oxygen to See, LEA Medizintechnik). Methods Nine female patients undergoing classical abdominoplasty were included in the study. Perforators and the perfusion zones of the deep inferior epigastric artery flap were marked on the patient's abdominal wall. Flap perfusion was quantitatively assessed by measuring blood flow, velocity, capillary oxygen saturation, and relative amount of hemoglobin for each zone preoperatively, after tumescent solution infiltration, following elevation of the flap on a single perforator, and after deep and superficial liposuction, respectively. Results The measurements taken after elevation of the flap were not significantly different than measurements taken after the liposuction procedures. Conclusions The liposuction procedure does not significantly alter the perfusion of perforator-based abdominal flaps in the early period. The abdominal tissue discarded in a classic abdominoplasty operation can be raised as a perforator flap and has been demonstrated to be a unique model for clinical research. PMID:28352599
Jowett, Nathan; Hadlock, Tessa A; Sela, Eyal; Toth, Miklos; Knecht, Rainald; Lörincz, Balazs B
2017-04-01
To objectively assess donor site morbidity after harvesting the facial artery musculomucosal flap. Use of the FAMM-flap in oral cavity reconstruction remains sporadic. This case series describes our newly developed standardized assessment of this flap in a floor of mouth (FOM) reconstructive setting. Standardized postoperative assessment of the FAMM flap for donor site wound complications, functional, facial mimetic and oncologic outcomes. There were no wound complications. Oral competence remained intact, tongue mobility was good to excellent, average word articulation score was 98%, and mimetic function excellent in all patients. Three patients experienced ipsilateral upper lip anesthesia, and five patients were noted to have slight dysfunction of the orbicularis oris resulting in a loss of lip height at rest. The FAMM flap is a reliable option for reconstruction of ablative defects of the FOM, and should be considered a workhorse flap for oral cavity defects. Unlike the submental island flap, a complete level I dissection may be concurrently performed without compromising the vascular supply to the FAMM flap. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Expanded flap to repair facial scar left by radiotherapy of hemangioma.
Zhao, Donghong; Ma, Xinrong; Li, Jiang; Zhang, Lingfeng; Zhu, Baozhen
2014-09-01
This study explored the feasibility and clinical efficacy of expanded flap to repair facial scar left by radiotherapy of hemangioma. From March 2000 to April 2011, 13 cases of facial cicatrices left by radiotherapy of hemangioma have been treated with implantation surgery of facial skin dilator under local anesthesia. After water flood expansion for 1-2 months, resection of facial scar was performed, and wound repairing with expansion flap transfer was done. Thirteen patients were followed up from 5 months to 3 years. All patients tolerated flap transfer well; no contracture occurred during the facial expansion flap transfer. The incision scar was not obvious, and its color and texture were identical to surrounding skin. In conclusion, the use of expanded flap transfer to repair the facial scar left by radiotherapy of hemangioma is advantageous due to its simplicity, flexibility, and large area of repairing. This method does not affect the subsequent facial appearance.
Notes on the technique of landing airplanes equipped with wing flaps
NASA Technical Reports Server (NTRS)
Gough, Melvin N
1936-01-01
The proper landing of airplanes equipped with flaps, although probably no more difficult than landing without them, requires a different technique. The effects of flaps on the aerodynamics characteristics of a wing are given and, with the aid of figures and diagrams, a detailed comparison of the glide and landing of an airplane with and without flaps is made. The dangers attending improper execution and the importance of such factors as air speed fuselage attitude, glide-path angle, and control manipulation, upon all of which a pilot bases his judgement, are emphasized. Of most importance in connection with the use of flaps are: the maintenance of a sufficient margin of speed above the stall; a decisive use of the controls at the proper time; more cautious use of power during the approach glide; and, above all, the willingness to accept the steep nose-down attitude necessary in the glide resulting from the use of flaps.
Active Control of Separation From the Flap of a Supercritical Airfoil
NASA Technical Reports Server (NTRS)
Melton, La Tunia Pack; Yao, Chung-Sheng; Seifert, Avi
2003-01-01
Active flow control in the form of periodic zero-mass-flux excitation was applied at several regions on the leading edge and trailing edge flaps of a simplified high-lift system t o delay flow separation. The NASA Energy Efficient Transport (EET) supercritical airfoil was equipped with a 15% chord simply hinged leading edge flap and a 25% chord simply hinged trailing edge flap. Detailed flow features were measured in an attempt to identify optimal actuator placement. The measurements included steady and unsteady model and tunnel wall pressures, wake surveys, arrays of surface hot-films, flow visualization, and particle image velocimetry (PIV). The current paper describes the application of active separation control at several locations on the deflected trailing edge flap. High frequency (F(+) approx.= 10) and low frequency amplitude modulation (F(+)AM approx.= 1) of the high frequency excitation were used for control. Preliminary efforts to combine leading and trailing edge flap excitations are also reported.
Gümüş, Nazım; Odemiş, Yusuf; Tuncer, Ersin; Yılmaz, Sarper
2013-08-01
The purpose of this study was to determine the effectiveness of topically applied minoxidil in the pharmacological delay phenomenon and to demonstrate the comparable microscopic and macroscopic changes between minoxidil-pretreated flaps and surgically delayed flaps. A modified version of the McFarlane flap was used. Group 1 rats, in which a caudally based dorsal skin flap was raised and sutured back, were the control group. In group II, minoxidil solution was spread over the marked skin flap area for 7 days. On the 7th day, a caudally based dorsal skin flap was elevated and then sutured back. Group III rats underwent a surgical delay procedure alone. On the 7th day after flap elevation, evaluation was done by histologic examination and calculation of the flap survival areas in all groups. The lowest flap survival rate appeared in group I and was statistically different from groups II and III. The mean surviving skin flap area in the minoxidil-pretreated group was significantly larger than that in the control group. After histologic evaluation, moderate angiogenesis was also detected in group II. We also found that surgical delay significantly reduced flap necrosis when compared to the minoxidil pretreatment group. According to our study, minoxidil may be considered an effective vasoactive agent for the stimulation of angiogenesis in rat cutaneous flaps and capable of achieving pharmacological delay and increasing flap survival. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
OTTRIA, L.; LUCIANI, F.; PIVA, P.; ALAGNA, A.M.; ARCURI, C.; BARTULI, F.N.
2017-01-01
SUMMARY Aim The purpose of the study was to analyze the healing of the deep and superficial lower first and second molars periodontium, after the surgical extraction of the contiguous impacted third molar, comparing 3 mucoperiosteal flap designs. Materials and methods 150 patients which had to undergo a impacted lower third molar surgery were enrolled in this study. They were checked from day 0 to day 90, in order to focus on the recovery quality of the soft tissues around the lower second molar, comparing 3 different flap designs. Results No intraoperatory incident happened. The complete recovery of the periodontium around the second molar has been shown in each patient after 90 days from surgery and each adverse reaction happened within the sixth week after surgery. Only 2 slight gengival recessions 0,5 mm have been find out. Conclusions The impacted third molar surgery is an operation that, if rightly programmed and performed, is relatively safe. Besides, the correct handling and management of periodontium around the second molar and the choice of the flap type to be used support a correct recovery on the second molar periodontium, avoiding any long-term damage. Clinical significance This study wanted to analyze the healing of the deep and superficial lower second molar periodontium, after the impacted lower third molar surgery. In order to improve the surgical technique used for lower third molar germectomies, we wanted to compare 3 different kind of flap designs. PMID:29285329
Conformational flexibility in the flap domains of ligand-free HIV protease.
Heaslet, Holly; Rosenfeld, Robin; Giffin, Mike; Lin, Ying Chuan; Tam, Karen; Torbett, Bruce E; Elder, John H; McRee, Duncan E; Stout, C David
2007-08-01
The crystal structures of wild-type HIV protease (HIV PR) in the absence of substrate or inhibitor in two related crystal forms at 1.4 and 2.15 A resolution are reported. In one crystal form HIV PR adopts an 'open' conformation with a 7.7 A separation between the tips of the flaps in the homodimer. In the other crystal form the tips of the flaps are 'curled' towards the 80s loop, forming contacts across the local twofold axis. The 2.3 A resolution crystal structure of a sixfold mutant of HIV PR in the absence of substrate or inhibitor is also reported. The mutant HIV PR, which evolved in response to treatment with the potent inhibitor TL-3, contains six point mutations relative to the wild-type enzyme (L24I, M46I, F53L, L63P, V77I, V82A). In this structure the flaps also adopt a 'curled' conformation, but are separated and not in contact. Comparison of the apo structures to those with TL-3 bound demonstrates the extent of conformational change induced by inhibitor binding, which includes reorganization of the packing between twofold-related flaps. Further comparison with six other apo HIV PR structures reveals that the 'open' and 'curled' conformations define two distinct families in HIV PR. These conformational states include hinge motion of residues at either end of the flaps, opening and closing the entire beta-loop, and translational motion of the flap normal to the dimer twofold axis and relative to the 80s loop. The alternate conformations also entail changes in the beta-turn at the tip of the flap. These observations provide insight into the plasticity of the flap domains, the nature of their motions and their critical role in binding substrates and inhibitors.
Flap Reconstruction for Pressure Ulcers: An Outcomes Analysis
Madden, James J.; Hoffman, Ashley N.; Kim, Justine S.; Thayer, Wesley P.; Nanney, Lillian B.; Spear, Marcia E.
2017-01-01
Background: Historically, complication rates after pressure ulcer reconstruction utilizing flap coverage have been high. Patients undergoing operations for pressure ulcer coverage typically have multiple risk factors for postoperative complications. The purpose of this study was to examine a large patient series in the pressure ulcer population to uncover objective evidence of the linkage between risk factors and outcomes after flap coverage. Methods: This study was a retrospective chart review of patients who underwent flap reconstruction for a pressure ulcer between 1997 and 2015. The characteristics of patients were analyzed to determine those who had complications such as pressure ulcer recurrence, wound dehiscence, and wound infection. Results: All patients (N = 276) underwent flap coverage of their pressure ulcers. The overall complication rate was 58.7% (162 patients). Wound dehiscence was the most common complication (31.2%), and the pressure ulcer recurrence rate was 28.6%. Multivariate regression for pressure ulcer recurrence revealed that body mass index <18.5 [relative risk (RR) 3.13], active smoking (RR 2.33), and ischial pressure ulcers (RR 3.46) were independent risk factors for pressure ulcer recurrence. Ischial pressure ulcers (RR 2.27) and preoperative osteomyelitis (RR 2.78) were independent risk factors for wound dehiscence. Diabetes was an independent risk factor for wound infection (RR 4.34). Conclusions: Our retrospective analysis revealed numerous factors that are associated with high rates of major postoperative complications. Risk factors must be taken into account when offering flap coverage, and risk-reducing strategies must be implemented in patients before pressure ulcer reconstruction. PMID:28203494
de Runz, Antoine; Brix, Muriel; Gisquet, Heloïse; Pujo, Julien; Minetti, Christophe; Colson, Thomas; Sorin, Thomas; Agrinier, Nelly; Simon, Etienne
2015-03-01
Major weight loss causes body deformities. Lower circumferential dermolipectomy with autologous gluteal augmentation by a fat island flap can restore a part of the body contour, but this procedure is associated with a high incidence of complications. The aim of this study was to analyse the benefit/risk ratio and the patients' satisfaction. All patients who underwent this procedure at the Nancy University Hospital over a 3-year period (between January 2010 and 2013) were reviewed; the complications were analysed and the patients' satisfaction rated. A total of 55 patients were included with a mean age of 41.0 years. The average body mass index of the patients was 28.2 kg/m² with a mean weight of 76.8 kg at the time of the procedure and a mean weight reduction of 49.6 kg. The mean operative time was 4.85 h. The average hospital stay was 6.1 days. The average haemoglobin loss was 3.0 g/dl, and 12 (21.8%) patients required a blood transfusion. Of the total number of patients, 22 (40%) developed at least one complication, including six (10.9%) major complications. Fifty-two patients answered the questionnaire; 49 (94.2%) patients would go through this procedure again. The overall satisfaction was rated as excellent by 29 (55.8%) patients and as pleasing by 22 (42.3%). The outcome was judged as excellent or pleasing for the abdomen by 29 (55.8%) and 20 (38.35%) patients, respectively, and for the buttocks by 17 (32.7%) and 29 (55.8%) patients, respectively. The quality of life was rated better after than before the intervention by 49 (94.2%) patients. Despite a high complication rate, the majority of patients confirmed that they would opt for this procedure again, showing an improvement in their quality of life with an aesthetic and functional benefit. III. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Wilkman, T; Husso, A; Lassus, P
2018-05-01
This study compared the three most used composite flaps in maxillofacial reconstructions in our institute. Between 2000 and 2012, a total of 163 patients with mandibular, maxillary, and orbital defects received either scapular, fibular, or iliac crest osseal reconstructions in Helsinki University Hospital, Departments of Plastic Surgery and Maxillofacial Surgery. Data regarding the patient demographics, complications, and outcomes were analyzed. There were 92 deep circumflex iliac artery flaps (56%), followed by 42 scapular (26%) and 29 fibular flaps (18%). The rate of flap loss was the highest in the deep circumflex iliac artery group (p = 0.001). Reconstructions using fibula were fastest (p = 0.001) and had lowest perioperative blood loss (p = 0.013). There were no significant differences in the number of early or late complications between the flaps, but donor site complications were more severe in deep circumflex iliac artery. Osteotomies as well as dental implants were safely performed in all flaps with equal results. All three flaps of this study can be performed with awareness of the deep circumflex iliac artery flap being the least reliable alternative. The knowledge of the advantages and disadvantages of several osseal-free flap alternatives is beneficial in selecting the best suitable method for each individual patient requiring maxillofacial osseal reconstruction.
Schein, Ophir; Westreich, Melvyn; Shalom, Avshalom
2013-09-01
Studies have focused on enhancing flap viability using superoxide dismutase (SOD), but only a few used SOD from human origin, and most gave the compound systemically. We evaluated the ability of SOD to improve random skin flap survival using human recombinant copper-zinc superoxide dismutase (Hr-CuZnSOD) in variable doses, injected intradermally into the flap. Seventy male Sprague Dawley rats were randomly assigned into 4 groups. Cephalic random pattern flaps were elevated on their backs and intradermal injections of different dosages of Hr-CuZnSOD were given 15 minutes before surgery. Flap survival was evaluated by fluorescein fluorescence. Analysis of variance (ANOVA) and t test statistical analyses were performed. Flap survival in all treated groups was significantly better than in the controls. The beneficial effect of HR-CuZnSOD on flap survival is attained when it is given intradermally into the flap tissue. Theoretically, Hr-CuZnSOD delivered with local anesthetics used in flap elevation may be a valuable clinical tool. Copyright © 2012 Wiley Periodicals, Inc.
Basterzi, Yavuz; Tenekeci, Goktekin
2016-04-01
Several options have been reported for the reconstruction of myelomeningocele defects. In this article, we present our experience on soft tissue reconstruction of myelomeningocele defects by using island propeller dorsal intercostal artery perforator (DIAP) flaps. Between January 2008 and February 2014, all newborns with large myelomeningocele defects (13 newborns) were reconstructed with island propeller DIAP flaps. All flaps survived completely. In 8 patients out of 13, venous insufficiency was observed which then resolved spontaneously. Flap donor sites were closed primarily. Myelomeningocele defects with a diameter larger than 5 cm require reconstruction with flaps. To mobilize a well-vascularized tissue over the defect without tension in which the suture lines will not overlap over the midline where the dura is repaired and over the meninges is one of the goals of reconstruction for such defects. Perforator propeller flaps enable us to reach those goals. Use of perforator flaps provides 2 important advantages, namely, more predictability and also more freedom in mobilizing flaps toward the defect. This study proves the reliability of DIAP propeller flaps in the reconstruction of myelomeningocele defects.
Distally based posterior interosseous flap: primary role in soft-tissue reconstruction of the hand.
Agir, Hakan; Sen, Cenk; Alagöz, Sahin; Onyedi, Murat; Isil, Eda
2007-09-01
A series of 15 consecutive patients with various hand defects requiring flap coverage was reviewed in this study. The defects were all covered with the distally based posterior interosseous flap. Its main indications were in complex hand trauma, severe burn injury, or skin cancer ablation, either acute or postprimary. In 12 of the patients, flaps survived completely. In 3 patients, there was partial necrosis of the distal part of the flap, which did not require additional surgical procedure. Radial nerve palsy was noted in one of the cases, with a complete recovery after 3 months. Donor site was closed directly in up to 4-cm-wide flaps, while larger flaps required skin grafting. No major anatomic variation was observed. Distally based posterior interosseous flap is a reliable choice for various types and areas of hand defects, with very low donor-site morbidity, and should be more commonly considered in clinical practice.
Vitse, J; Bekara, F; Bertheuil, N; Sinna, R; Chaput, B; Herlin, C
2017-02-01
Current data on upper extremity propeller flaps are poor and do not allow the assessment of the safety of this technique. A systematic literature review was conducted searching PubMed, EMBASE, and the Cochrane Library electronic databases, and the selection process was adapted from the preferred reporting items for systematic reviews and meta-analysis statement. The final analysis included ten relevant articles involving 117 flaps. The majority of flaps were used for the hand, distal wrist, and elbow. The radial artery perforator and ulnar artery perforator were the most frequently used flaps. The were 7% flaps with venous congestion and 3% with complete necrosis. No difference in complications rate was found for different flaps sites. Perforator-based propeller flaps appear to be an interesting procedure for covering soft tissue defects involving the upper extremities, even for large defects, but the procedure requires experience and close monitoring. II.
Nasoseptal flap necrosis: a rare complication of endoscopic endonasal surgery.
Chabot, Joseph D; Patel, Chirag R; Hughes, Marion A; Wang, Eric W; Snyderman, Carl H; Gardner, Paul A; Fernandez-Miranda, Juan C
2018-05-01
OBJECTIVE The vascularized nasoseptal flap (NSF) has become the workhorse for skull base reconstruction during endoscopic endonasal surgery (EES) of the ventral skull base. Although infrequently reported, as with any vascularized flap the NSF may undergo ischemic necrosis and become a nidus for infection. The University of Pittsburgh Medical Center's experience with NSF was reviewed to determine the incidence of necrotic NSF in patients following EES and describe the clinical presentation, imaging characteristics, and risk factors associated with this complication. METHODS The electronic medical records of 1285 consecutive patients who underwent EES at the University of Pittsburgh Medical Center between January 2010 and December 2014 were retrospectively reviewed. From this first group, a list of all patients in whom NSF was used for reconstruction was generated and further refined to determine if the patient returned to the operating room and the cause of this reexploration. Patients were included in the final analysis if they underwent endoscopic reexploration for suspected CSF leak or meningitis. Those patients who returned to the operating room for staged surgery or hematoma were excluded. Two neurosurgeons and a neuroradiologist, who were blinded to each other's results, assessed the MRI characteristics of the included patients. RESULTS In total, 601 patients underwent NSF reconstruction during the study period, and 49 patients met the criteria for inclusion in the final analysis. On endoscopic exploration, 8 patients had a necrotic, nonviable NSF, while 41 patients had a viable NSF with a CSF leak. The group of patients with a necrotic, nonviable NSF was then compared with the group with viable NSF. All 8 patients with a necrotic NSF had clinical and laboratory evidence indicative of meningitis compared with 9 of 41 patients with a viable NSF (p < 0.001). Four patients with necrotic flaps developed epidural empyema compared with 2 of 41 patients in the viable
The Omental Free Flap-A Review of Usage and Physiology.
Mazzaferro, Daniel; Song, Ping; Massand, Sameer; Mirmanesh, Michael; Jaiswal, Rohit; Pu, Lee L Q
2018-03-01
The omental flap has a rich history of use over the last century, and specifically as a free flap in the last four decades. It has a wide variety of applications in reconstructive surgery and has shown itself to be a reliable donor tissue. We seek to review the properties that make the omental free flap a valuable tool in reconstruction, as well as its many surgical applications in all anatomic regions of the body. We conducted a narrative review of the literature on Medline and Google Scholar. We reviewed basic science articles discussing the intrinsic properties of omental tissue, along with clinical papers describing its applications. The omental free flap is anatomically suitable for harvest and wound coverage and has molecular properties that promote healing and improve function at recipient sites. It has demonstrated utility in a wide variety of reconstructive procedures spanning the head and neck, extremities, and viscera and for several purposes, including wound coverage, lymphedema treatment, and vascularization. It is also occasionally employed in the thoracic cavity and chest wall, though more often as a pedicled flap. More novel uses include its use for cerebrospinal fluid leaks. The omental free flap is a valuable option for reconstructive efforts in nearly all anatomic regions. This is a result of its inherent anatomy and vascularity, and its angiogenic, immunogenic, and lymphatic properties. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Heart rate and estimated energy expenditure of flapping and gliding in black-browed albatrosses.
Sakamoto, Kentaro Q; Takahashi, Akinori; Iwata, Takashi; Yamamoto, Takashi; Yamamoto, Maki; Trathan, Philip N
2013-08-15
Albatrosses are known to expend only a small amount of energy during flight. The low energy cost of albatross flight has been attributed to energy-efficient gliding (soaring) with sporadic flapping, although little is known about how much time and energy albatrosses expend in flapping versus gliding during cruising flight. Here, we examined the heart rates (used as an instantaneous index of energy expenditure) and flapping activities of free-ranging black-browed albatrosses (Thalassarche melanophrys) to estimate the energy cost of flapping as well as time spent in flapping activities. The heart rate of albatrosses during flight (144 beats min(-1)) was similar to that while sitting on the water (150 beats min(-1)). In contrast, heart rate was much higher during takeoff and landing (ca. 200 beats min(-1)). Heart rate during cruising flight was linearly correlated with the number of wing flaps per minute, suggesting an extra energy burden of flapping. Albatrosses spend only 4.6±1.4% of their time flapping during cruising flight, which was significantly lower than during and shortly after takeoff (9.8±3.5%). Flapping activity, which amounted to just 4.6% of the time in flight, accounted for 13.3% of the total energy expenditure during cruising flight. These results support the idea that albatrosses achieve energy-efficient flight by reducing the time spent in flapping activity, which is associated with high energy expenditure.
Design of Supersonic Transport Flap Systems for Thrust Recovery at Subsonic Speeds
NASA Technical Reports Server (NTRS)
Mann, Michael J.; Carlson, Harry W.; Domack, Christopher S.
1999-01-01
A study of the subsonic aerodynamics of hinged flap systems for supersonic cruise commercial aircraft has been conducted using linear attached-flow theory that has been modified to include an estimate of attainable leading edge thrust and an approximate representation of vortex forces. Comparisons of theoretical predictions with experimental results show that the theory gives a reasonably good and generally conservative estimate of the performance of an efficient flap system and provides a good estimate of the leading and trailing-edge deflection angles necessary for optimum performance. A substantial reduction in the area of the inboard region of the leading edge flap has only a minor effect on the performance and the optimum deflection angles. Changes in the size of the outboard leading-edge flap show that performance is greatest when this flap has a chord equal to approximately 30 percent of the wing chord. A study was also made of the performance of various combinations of individual leading and trailing-edge flaps, and the results show that aerodynamic efficiencies as high as 85 percent of full suction are predicted.
Preliminary Measurements of the Noise Characteristics of Some Jet-Augmented-Flap Configurations
NASA Technical Reports Server (NTRS)
Maglieri, Domenic J.; Hubbard, Harvey H.
1959-01-01
Experimental noise studies were conducted on model configurations of some proposed jet-augmented flaps to determine their far-field noise characteristics. The tests were conducted using cold-air jets of circular and rectangular exits having equal areas, at pressure ratios corresponding to exit velocities slightly below choking. Results indicated that the addition of a flap to a nozzle may change both its noise radiation pattern and frequency spectrum. Large reductions in the noise radiated in the downward direction are realized when the flow from a long narrow rectangular nozzle as permitted to attach to and flow along a large flap surface. Deflecting or turning the jet flow by means of impingement on the under surfaces increases the noise radiated in all directions and especially in the downward direction for the jet-flap configurations tested. Turning of the flow from nozzles by means of a flap turns the noise pattern approximately an equal amount. The principle of using a jet-flap shield with flow attachment may have some application as a noise suppressor.
Jiang, Maohua; Yang, Xiaoliang; Wei, Bangmin; Li, Yinghao
2012-03-01
To investigate the method and effectiveness of repairing sacrococcygeal pressure sores with modified upper gluteal rhomboid fasciocutaneous flap. Between January 2004 and March 2011, 43 patients with sacrococcygeal pressure sores were treated. There were 25 males and 18 females with an average age of 63 years (range, 38-95 years). The disease duration was 3 months to 2 years and 6 months (mean, 8.5 months). The size of pressure sores ranged from 6 cm x 5 cm to 18 cm x 13 cm. According to the extent and lesion degree of pressure scores, 23 pressure sores were rated as degree III and 20 pressure sores as degree IV. The modified upper gluteal rhomboid flap was designed, one-side upper gluteal fasciocutaneous flaps were transplanted to repair sacrococcygeal pressure sores in 19 cases and two-side flaps in 24 cases. The size of one side flap ranged from 6.5 cm x 4.5 cm to 18.0 cm x 11.5 cm. Fluid under flap occurred in 1 case and edge necrosis of the flaps in 3 cases at 7 days after operation, which were cured after drainage and dressing change; the other flaps survived, and incisions healed by first intention. All patients were followed up 6 months to 3 years with an average of 11 months. Two patients relapsed at 5 months and 8 months, respectively; the other patients had no recurrence. The color of the flaps was normal, and the appearance and elasticity of the flaps were good. The modified upper gluteal rhomboid fasciocutaneous flap has the advantages of simple design and operation, less injury, and reliable effect in repairing sacrococcygeal pressure sores.
Detached Eddy Simulation of Flap Side-Edge Flow
NASA Technical Reports Server (NTRS)
Balakrishnan, Shankar K.; Shariff, Karim R.
2016-01-01
Detached Eddy Simulation (DES) of flap side-edge flow was performed with a wing and half-span flap configuration used in previous experimental and numerical studies. The focus of the study is the unsteady flow features responsible for the production of far-field noise. The simulation was performed at a Reynolds number (based on the main wing chord) of 3.7 million. Reynolds Averaged Navier-Stokes (RANS) simulations were performed as a precursor to the DES. The results of these precursor simulations match previous experimental and RANS results closely. Although the present DES simulations have not reached statistical stationary yet, some unsteady features of the developing flap side-edge flowfield are presented. In the final paper it is expected that statistically stationary results will be presented including comparisons of surface pressure spectra with experimental data.
Han, Ba Leun; Choi, Hwan Jun
2014-03-01
Sequential flap coverage might be required for recurrent defects, but reusing a flap as a donor site has seldom been reported. The concept of a "free-style flap" has been developed, and it allows reconstructive surgeons to raise flaps with various designs reliably, even at sites of previous flap surgery. This article presents the concept of free-style recycling of a tensor fascia lata flap into a perforator-based flap separated in 2 planes in a patient with a recurrent bilateral trochanteric defect. If a reliable perforator is preserved and identified within the tissues by computed tomography angiography or a Doppler device, a new perforator flap can be designed and raised at the previous flap site.
Cervical apron flap reconstruction: a technique for second-stage revision.
Spiro, R H; Chaglassian, T A
1979-08-01
A technique for second-stage revision of a cervical apron flap is described. Food particle retention and pocketing in hair-bearing recesses can be minimized by accurately trimming and contouring the flap to fit smoothly into the oral defect.
Shark island pedicle flap for repair of combined nasal ala-perialar defects.
Cvancara, Joseph L; Wentzell, J Michael
2006-05-01
The combined nasal ala-perialar defect involving the concave intersection of the lateral nasal ala, nasal sidewall, cheek, and upper cutaneous lip is a problem for reconstructive surgery. During repair of combined cheek and nose defects, it is important not to blunt the alar facial sulcus. Defects involving these adjacent cosmetic units can be repaired by using combination procedures such as a flap/graft. Our purpose is to introduce, describe, and illustrate a one-stage flap repair descriptively named the "shark" island pedicle flap (SIPF). The SIPF was developed for a specific combined nasal ala-perialar defect. This reconstruction restores the natural contours, preserves cosmetic boundaries, and eliminates the need for pexing sutures and graft/flap combinations. The SIPF is an island pedicle flap with a superior arm that rotates 90 degrees into the wound. This arm repairs the alar portion of the defect. The advancing island pedicle flap repairs the alar facial sulcus. The 90 degrees rotation of the superior arm forces the alar portion of the flap to tilt 90 degrees relative to the remaining body of the flap, forming an inverted cone of redundancy. Natural re-creation of the lateral ala and the alar facial sulcus results. Illustrative examples with a descriptive technique are provided for the SIPF. A well-planned SIPF reconstruction can provide exceptional cosmetic and functional results. Cutaneous reconstructive surgeons will find the SIPF useful and reproducible in their armamentarium for single-stage aesthetic and functional repair of a specific combined lateral ala-adjacent perialar tissue defect.
Distally Based Sural Artery Peroneus Flap (DBSPF) for Foot and Ankle Reconstruction
Ebrahiem, Ahmed Ali; Manas, Raj Kumar
2017-01-01
Background: Reconstruction of soft-tissue defects in lower third of leg, ankle, and foot has been a challenge and reconstructive surgeons have been trying to innovate different flaps. To solve this issue, we propose a distally based sural artery peroneus flap (DBSPF) in which we include superficial portion of the peroneus brevis muscle and its blood supply with the peroneal artery distally. The aim of this study was to evaluate the functional outcome and its usefulness over conventional distal sural artery flap or other local options available. Methods: This is a case series of 20 patients that include a DBSPF that was done for defects around ankle, distal leg, and foot caused by trauma or tumor ablation within the period of June 2013 to March 2015 in Kasralainy Hospital, Cairo. All cases were evaluated according to flap vascularity, distal reach of flap, aesthetic outcome, and donor-site morbidity. Results: All flaps survived. One flap developed venous congestion that subsided spontaneously with limb elevation. The flap dimension ranged from 42 cm to 442 cm2, and it reached the midfoot easily. The pivot point was kept as low as 2–6 cm from lateral malleolus according to location of perforators. The ankle stability was maintained, and the desired aesthetic outcome was achieved. Conclusions: The DBSPF is an addition to the armamentarium in plastic surgery for defects around ankle, distal leg, and foot. It is an easy and swift procedure as compared with complex microsurgical reconstruction. PMID:28507850
Gong, Xu; Cui, Jianli; Jiang, Ziping; Lu, Laijin; Li, Xiucun
2018-03-01
Few clinical retrospective studies have reported the risk factors of pedicled flap necrosis in hand soft tissue reconstruction. The aim of this study was to identify non-technical risk factors associated with pedicled flap perioperative necrosis in hand soft tissue reconstruction via a multivariate logistic regression analysis. For patients with hand soft tissue reconstruction, we carefully reviewed hospital records and identified 163 patients who met the inclusion criteria. The characteristics of these patients, flap transfer procedures and postoperative complications were recorded. Eleven predictors were identified. The correlations between pedicled flap necrosis and risk factors were analysed using a logistic regression model. Of 163 skin flaps, 125 flaps survived completely without any complications. The pedicled flap necrosis rate in hands was 11.04%, which included partial flap necrosis (7.36%) and total flap necrosis (3.68%). Soft tissue defects in fingers were noted in 68.10% of all cases. The logistic regression analysis indicated that the soft tissue defect site (P = 0.046, odds ratio (OR) = 0.079, confidence interval (CI) (0.006, 0.959)), flap size (P = 0.020, OR = 1.024, CI (1.004, 1.045)) and postoperative wound infection (P < 0.001, OR = 17.407, CI (3.821, 79.303)) were statistically significant risk factors for pedicled flap necrosis of the hand. Soft tissue defect site, flap size and postoperative wound infection were risk factors associated with pedicled flap necrosis in hand soft tissue defect reconstruction. © 2017 Royal Australasian College of Surgeons.
Measurement of the volume of the pedicled TRAM flap in immediate breast reconstruction.
Chang, K P; Lin, S D; Hou, M F; Lee, S S; Tsai, C C
2001-12-01
The transverse rectus abdominis musculocutaneous (TRAM) flap is now accepted as the standard for breast reconstruction, but achieving symmetrical breast reconstruction is still a challenge. A precise estimate of the volume of the flap is necessary to reconstruct a symmetrical and aesthetically pleasing breast. Many methods have been developed to overcome this problem, but they have not been suitable for the pedicled TRAM flap. By using a self-made device based on the Archimedes' principle, the authors can calculate accurately the volume of the pedicled TRAM flap and predict reliably the breast volume intraoperatively. The "procedure" is based on a self-made box into which the pedicled TRAM flap is placed. Warm saline is added to the box and the flap is then removed. Flap volume is calculated easily by determining the difference between the preestimated volume of the box and the volume of the residual water. From February to May 2000, this method was used on 28 patients to predict breast volume for breast reconstruction. This study revealed that the difference of the maximal chest circumferences (the index of the breast volume) demonstrates a positive correlation with the difference of the volumes and weights between the mastectomy specimen and the net TRAM flap. However, a more closely positive correlation exists between the differences of maximal chest circumference volume (r = 0.677) than maximal chest circumference weight (r = 0.618). These data reveal that the reconstructed breast's volume has a closer relationship with the volume of the net pedicled TRAM flap, rather than with its weight.
Temporalis myofascial flap for primary cranial base reconstruction after tumor resection.
Eldaly, Ahmed; Magdy, Emad A; Nour, Yasser A; Gaafar, Alaa H
2008-07-01
To evaluate the use of the temporalis myofascial flap in primary cranial base reconstruction following surgical tumor ablation and to explain technical issues, potential complications, and donor site consequences along with their management. Retrospective case series. Tertiary referral center. Forty-one consecutive patients receiving primary temporalis myofascial flap reconstructions following cranial base tumor resections in a 4-year period. Flap survival, postoperative complications, and donor site morbidity. Patients included 37 males and 4 females ranging in age from 10 to 65 years. Two patients received preoperative and 18 postoperative radiation therapy. Patient follow-up ranged from 4 to 39 months. The whole temporalis muscle was used in 26 patients (63.4%) and only part of a coronally split muscle was used in 15 patients (36.6%). Nine patients had primary donor site reconstruction using a Medpor((R)) (Porex Surgical, Inc., Newnan, GA) temporal fossa implant; these had excellent aesthetic results. There were no cases of complete flap loss. Partial flap dehiscence was seen in six patients (14.6%); only two required surgical débridement. None of the patients developed cerebrospinal leaks or meningitis. One patient was left with complete paralysis of the temporal branch of the facial nerve. Three patients (all had received postoperative irradiation) developed permanent trismus. The temporalis myofascial flap was found to be an excellent reconstructive alternative for a wide variety of skull base defects following tumor ablation. It is a very reliable, versatile flap that is usually available in the operative field with relatively low donor site aesthetic and functional morbidity.
Funding analysis of bilateral autologous free-flap breast reconstructions in Australia.
Sinha, Shiba; Ruskin, Olivia; McCombe, David; Morrison, Wayne; Webb, Angela
2015-08-01
Bilateral breast reconstructions are being increasingly performed. Autologous free-flap reconstructions represent the gold standard for post-mastectomy breast reconstruction but are resource intensive. This study aims to investigate the difference between hospital reimbursement and true cost of bilateral autologous free-flap reconstructions. Retrospective analysis of patients who underwent bilateral autologous free-flap reconstructions at a single Australian tertiary referral centre was performed. Hospital reimbursement was determined from coding analysis. A true cost analysis was also performed. Comparisons were made considering the effect of timing, indication and complications of the procedure. Forty-six bilateral autologous free-flap procedures were performed (87 deep inferior epigastric perforators (DIEPs), four superficial inferior epigastric artery perforator flaps (SIEAs) and one muscle-sparing free transverse rectus abdominis myocutaneous flap (MS-TRAM)). The mean funding discrepancy between hospital reimbursement and actual cost was $12,137 ± $8539 (mean ± standard deviation (SD)) (n = 46). Twenty-four per cent (n = 11) of the cases had been coded inaccurately. If these cases were excluded from analysis, the mean funding discrepancy per case was $9168 ± $7453 (n = 35). Minor and major complications significantly increased the true cost and funding discrepancy (p = 0.02). Bilateral free-flap breast reconstructions performed in Australian public hospitals result in a funding discrepancy. Failure to be economically viable threatens the provision of this procedure in the public system. Plastic surgeons and hospital managers need to adopt measures in order to make these gold-standard procedures cost neutral. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Yadav, Sunil; Dhupar, Anita; Dhupar, Vikas; Akkara, Francis; Mittal, Hitesh C.
2014-01-01
The resection of oral cavity tumor and malignancies often causes functional disabilities like deglutition and articulation. Maxillectomy is a very common surgical procedure carried out for the management of benign and malignant tumors of maxilla. Irrespective of the procedure, there is a common end result that is the defect. Several soft tissue flaps can be used for reconstruction of maxillectomy defect. Keeping the parameters of reconstruction in mind it is ideal to reconstruct the maxillary defect with either the free flaps or the regional flaps. Of all regional flaps, the temporalis myofascial flap (TMF) provides a high degree of reliability, vascularity, adequate bulk, and proximity to the defect in the oral and maxillofacial region. PMID:25937744
Flapping inertia for selected rotor blades
NASA Technical Reports Server (NTRS)
Berry, John D.; May, Matthew J.
1991-01-01
Aerodynamics of helicopter rotor systems cannot be investigated without consideration for the dynamics of the rotor. One of the principal properties of the rotor which affects the rotor dynamics is the inertia of the rotor blade about its root attachment. Previous aerodynamic investigation have been performed on rotor blades with a variety of planforms to determine the performance differences due to blade planform. The blades tested for this investigation have been tested on the U.S. Army 2 meter rotor test system (2MRTS) in the NASA Langley 14 by 22 foot subsonic tunnel for hover performance. This investigation was intended to provide fundamental information on the flapping inertia of five rotor blades with differing planforms. The inertia of the bare cuff and the cuff with a blade extension were also measured for comparison with the inertia of the blades. Inertia was determined using a swing testing technique, using the period of oscillation to determine the effective flapping inertia. The effect of damping in the swing test was measured and described. A comparison of the flapping inertials for rectangular and tapered planform blades of approximately the same mass showed the tapered blades to have a lower inertia, as expected.
Aerodynamic characteristics of the ventilated design for flapping wing micro air vehicle.
Zhang, G Q; Yu, S C M
2014-01-01
Inspired by superior flight performance of natural flight masters like birds and insects and based on the ventilating flaps that can be opened and closed by the changing air pressure around the wing, a new flapping wing type has been proposed. It is known that the net lift force generated by a solid wing in a flapping cycle is nearly zero. However, for the case of the ventilated wing, results for the net lift force are positive which is due to the effect created by the "ventilation" in reducing negative lift force during the upstroke. The presence of moving flaps can serve as the variable in which, through careful control of the areas, a correlation with the decrease in negative lift can be generated. The corresponding aerodynamic characteristics have been investigated numerically by using different flapping frequencies and forward flight speeds.