Sample records for laboratory assay techniques

  1. 21 CFR 225.158 - Laboratory assays.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 4 2011-04-01 2011-04-01 false Laboratory assays. 225.158 Section 225.158 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS... Laboratory assays. Where the results of laboratory assays of drug components, including assays by State feed...

  2. 21 CFR 225.158 - Laboratory assays.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Laboratory assays. 225.158 Section 225.158 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS... Laboratory assays. Where the results of laboratory assays of drug components, including assays by State feed...

  3. Cost of gentamicin assays carried out by microbiology laboratories.

    PubMed Central

    Vacani, P F; Malek, M M; Davey, P G

    1993-01-01

    AIMS--To assess the current range of prices charged for gentamicin assays in United Kingdom laboratories; and to examine the laboratories' likely response to increases or decreases in the demand for the service. METHODS--A postal survey of the 420 members of the Association of Medical Microbiologists was used to establish the range of prices charged for aminoglycoside assays. Additionally, eight private institutions were contacted to determine what the private sector was charging for aminoglycoside assays. Reagent costs in the NHS laboratories were calculated by dividing the total cost of all aminoglycoside assay kits by the number of samples analysed. RESULTS--The NHS and the private institutions both showed a wide price variation. Prices charged to an in-hospital requester for a peak and trough assay ranged from 5.00 pounds to 68.20 pounds (n = 44), and to an external private hospital, under a bulk service contract, from 5.00 pounds to 96.00 pounds (n = 47). Prices charged by private laboratories ranged from 49.00 pounds to 84.00 pounds (n = 8). There was a log linear correlation in the NHS laboratories between the reagent costs per assay and the number of assays performed per year, and most laboratories thought that their price per assay would be sensitive to increases or decreases in demand. Laboratories which had purchased their assay machines had lower reagent costs per assay but higher repair and maintenance costs. Overall, number of assays performed and method of payment for assay machinery only accounted for 44.8% of the observed variation in assay kit costs. CONCLUSIONS--The price range for gentamicin assays in the United Kingdom is wide and is only partially explained by the number of assays performed. Most laboratories believe that they would experience a reduction in unit cost as output increases. The currently offered range of prices is, in part, due to variation in the laboratories' approach to costing the service provided and some laboratories

  4. A Direct, Competitive Enzyme-Linked Immunosorbent Assay (ELISA) as a Quantitative Technique for Small Molecules

    ERIC Educational Resources Information Center

    Powers, Jennifer L.; Rippe, Karen Duda; Imarhia, Kelly; Swift, Aileen; Scholten, Melanie; Islam, Naina

    2012-01-01

    ELISA (enzyme-linked immunosorbent assay) is a widely used technique with applications in disease diagnosis, detection of contaminated foods, and screening for drugs of abuse or environmental contaminants. However, published protocols with a focus on quantitative detection of small molecules designed for teaching laboratories are limited. A…

  5. How-to-do-it: Immunological Assays for the Classroom 1. Enzyme Linked Immunosorbent Assay (ELISA): A Laboratory Tool for Demonstration of Antibody-Antigen Interaction.

    ERIC Educational Resources Information Center

    Russo, A. J.; And Others

    1984-01-01

    Background information, list of required materials, and procedures are provided for an immunological assay which has been modified for use as a classroom/laboratory demonstration of antigen-antibody reaction. The assay is designed for a two and one-half hour laboratory period but may be modified for one hour laboratories. (JN)

  6. Advanced analysis techniques for uranium assay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geist, W. H.; Ensslin, Norbert; Carrillo, L. A.

    2001-01-01

    Uranium has a negligible passive neutron emission rate making its assay practicable only with an active interrogation method. The active interrogation uses external neutron sources to induce fission events in the uranium in order to determine the mass. This technique requires careful calibration with standards that are representative of the items to be assayed. The samples to be measured are not always well represented by the available standards which often leads to large biases. A technique of active multiplicity counting is being developed to reduce some of these assay difficulties. Active multiplicity counting uses the measured doubles and triples countmore » rates to determine the neutron multiplication (f4) and the product of the source-sample coupling ( C ) and the 235U mass (m). Since the 35U mass always appears in the multiplicity equations as the product of Cm, the coupling needs to be determined before the mass can be known. A relationship has been developed that relates the coupling to the neutron multiplication. The relationship is based on both an analytical derivation and also on empirical observations. To determine a scaling constant present in this relationship, known standards must be used. Evaluation of experimental data revealed an improvement over the traditional calibration curve analysis method of fitting the doubles count rate to the 235Um ass. Active multiplicity assay appears to relax the requirement that the calibration standards and unknown items have the same chemical form and geometry.« less

  7. Inter-laboratory comparison of the in vivo comet assay including three image analysis systems.

    PubMed

    Plappert-Helbig, Ulla; Guérard, Melanie

    2015-12-01

    To compare the extent of potential inter-laboratory variability and the influence of different comet image analysis systems, in vivo comet experiments were conducted using the genotoxicants ethyl methanesulfonate and methyl methanesulfonate. Tissue samples from the same animals were processed and analyzed-including independent slide evaluation by image analysis-in two laboratories with extensive experience in performing the comet assay. The analysis revealed low inter-laboratory experimental variability. Neither the use of different image analysis systems, nor the staining procedure of DNA (propidium iodide vs. SYBR® Gold), considerably impacted the results or sensitivity of the assay. In addition, relatively high stability of the staining intensity of propidium iodide-stained slides was found in slides that were refrigerated for over 3 months. In conclusion, following a thoroughly defined protocol and standardized routine procedures ensures that the comet assay is robust and generates comparable results between different laboratories. © 2015 Wiley Periodicals, Inc.

  8. Working with Enzymes - Where Is Lactose Digested? An Enzyme Assay for Nutritional Biochemistry Laboratories

    NASA Astrophysics Data System (ADS)

    Pope, Sandi R.; Tolleson, Tonya D.; Williams, R. Jill; Underhill, Russell D.; Deal, S. Todd

    1998-06-01

    At Georgia Southern University, we offer a sophomore-level introductory biochemistry course that is aimed at nutrition and chemistry education majors. The laboratory portion of this course has long lacked an experimental introduction to enzymes. We have developed a simple enzyme assay utilizing lactase enzyme from crushed LactAid tablets and a 5% lactose solution ("synthetic milk"). In the experiment, the students assay the activity of the enzyme on the "synthetic milk" at pHs of approximately 1, 6, and 8 with the stated goal of determining where lactose functions in the digestive tract. The activity of the lactase may be followed chromatographically or spectrophotometrically. The experiment, which is actually a simple pH assay, is easily implemented in allied health chemistry laboratory courses and readily lends itself to adaptation for more complex kinetic assays in upper-level biochemistry laboratory courses. The experimental details, including a list of required supplies and hints for implementation, are provided.

  9. Laboratory automation of high-quality and efficient ligand-binding assays for biotherapeutic drug development.

    PubMed

    Wang, Jin; Patel, Vimal; Burns, Daniel; Laycock, John; Pandya, Kinnari; Tsoi, Jennifer; DeSilva, Binodh; Ma, Mark; Lee, Jean

    2013-07-01

    Regulated bioanalytical laboratories that run ligand-binding assays in support of biotherapeutics development face ever-increasing demand to support more projects with increased efficiency. Laboratory automation is a tool that has the potential to improve both quality and efficiency in a bioanalytical laboratory. The success of laboratory automation requires thoughtful evaluation of program needs and fit-for-purpose strategies, followed by pragmatic implementation plans and continuous user support. In this article, we present the development of fit-for-purpose automation of total walk-away and flexible modular modes. We shared the sustaining experience of vendor collaboration and team work to educate, promote and track the use of automation. The implementation of laboratory automation improves assay performance, data quality, process efficiency and method transfer to CRO in a regulated bioanalytical laboratory environment.

  10. The LabTube - a novel microfluidic platform for assay automation in laboratory centrifuges.

    PubMed

    Kloke, A; Fiebach, A R; Zhang, S; Drechsel, L; Niekrawietz, S; Hoehl, M M; Kneusel, R; Panthel, K; Steigert, J; von Stetten, F; Zengerle, R; Paust, N

    2014-05-07

    Assay automation is the key for successful transformation of modern biotechnology into routine workflows. Yet, it requires considerable investment in processing devices and auxiliary infrastructure, which is not cost-efficient for laboratories with low or medium sample throughput or point-of-care testing. To close this gap, we present the LabTube platform, which is based on assay specific disposable cartridges for processing in laboratory centrifuges. LabTube cartridges comprise interfaces for sample loading and downstream applications and fluidic unit operations for release of prestored reagents, mixing, and solid phase extraction. Process control is achieved by a centrifugally-actuated ballpen mechanism. To demonstrate the workflow and functionality of the LabTube platform, we show two LabTube automated sample preparation assays from laboratory routines: DNA extractions from whole blood and purification of His-tagged proteins. Equal DNA and protein yields were observed compared to manual reference runs, while LabTube automation could significantly reduce the hands-on-time to one minute per extraction.

  11. Analytic Validation of Immunohistochemistry Assays: New Benchmark Data From a Survey of 1085 Laboratories.

    PubMed

    Stuart, Lauren N; Volmar, Keith E; Nowak, Jan A; Fatheree, Lisa A; Souers, Rhona J; Fitzgibbons, Patrick L; Goldsmith, Jeffrey D; Astles, J Rex; Nakhleh, Raouf E

    2017-09-01

    - A cooperative agreement between the College of American Pathologists (CAP) and the United States Centers for Disease Control and Prevention was undertaken to measure laboratories' awareness and implementation of an evidence-based laboratory practice guideline (LPG) on immunohistochemical (IHC) validation practices published in 2014. - To establish new benchmark data on IHC laboratory practices. - A 2015 survey on IHC assay validation practices was sent to laboratories subscribed to specific CAP proficiency testing programs and to additional nonsubscribing laboratories that perform IHC testing. Specific questions were designed to capture laboratory practices not addressed in a 2010 survey. - The analysis was based on responses from 1085 laboratories that perform IHC staining. Ninety-six percent (809 of 844) always documented validation of IHC assays. Sixty percent (648 of 1078) had separate procedures for predictive and nonpredictive markers, 42.7% (220 of 515) had procedures for laboratory-developed tests, 50% (349 of 697) had procedures for testing cytologic specimens, and 46.2% (363 of 785) had procedures for testing decalcified specimens. Minimum case numbers were specified by 85.9% (720 of 838) of laboratories for nonpredictive markers and 76% (584 of 768) for predictive markers. Median concordance requirements were 95% for both types. For initial validation, 75.4% (538 of 714) of laboratories adopted the 20-case minimum for nonpredictive markers and 45.9% (266 of 579) adopted the 40-case minimum for predictive markers as outlined in the 2014 LPG. The most common method for validation was correlation with morphology and expected results. Laboratories also reported which assay changes necessitated revalidation and their minimum case requirements. - Benchmark data on current IHC validation practices and procedures may help laboratories understand the issues and influence further refinement of LPG recommendations.

  12. Issues in the analyze of low content gold mining samples by fire assay technique

    NASA Astrophysics Data System (ADS)

    Cetean, Valentina

    2016-04-01

    The classic technique analyze of samples with low gold content - below 0.1 g/t (=100 ppb = parts per billion), either ore or gold sediments, involves the preparation of sample by fire assay extraction, followed by the chemical attack with aqua regia (hydrochloric and nitric acid) and measuring the gold content by atomic absorption spectrometry or inductively coupled mass spectrometry. The issues raised by this analysis are well known for the world laboratories, commercial or research ones. The author's knowledge regarding this method of determining the gold content, accumulated in such laboratory from Romania (with more than 40 years of experience, even if not longer available from 2014) confirms the obtaining of reliable results required a lot of attention, amount of work and the involving of an experienced fire assayer specialist. The analytical conclusion for a research laboratory is that most reliable and statistically valid results are till reached for samples with more than 100 ppb gold content; the degree of confidence below this value is lower than 90%. Usually, for samples below 50 ppb, it does not exceed 50-70 %, unless without very strictly control of each stage, that involve additional percentage of hours allocated for successive extracting tests and knowing more precisely the other compounds that appear in the sample (Cu, Sb, As, sulfur / sulphides, Te, organic matter, etc.) or impurities. The most important operation is the preparation, namely: - grinding and splitting of sample (which can cause uneven distribution of gold flakes in the double samples for analyzed); - pyro-metallurgical recovery of gold = fire assay stage, involving the more precise temperature control in furnace during all stages (fusion and cupellation) and adjusting of the fire assay flux components to produce a successful fusion depending of the sample matrix and content; - reducing the sample weight to decrease the amount of impurities that can be concentrated in the lead button

  13. Laboratory Assays for Epstein-Barr Virus-Related Disease

    PubMed Central

    Gulley, Margaret L.; Tang, Weihua

    2008-01-01

    Epstein-Barr virus (EBV) infects various cell types in a wide spectrum of benign and malignant diseases. Laboratory tests for EBV have improved and are increasingly used in diagnosis, prognosis, prediction, and prevention of diseases ranging from infectious mononucleosis to selected subtypes of lymphoma, sarcoma, and carcinoma. Indeed, the presence of EBV is among the most effective tumor markers supporting clinical management of cancer patients. In biopsies, localization of EBER transcripts by in situ hybridization remains the gold standard for identifying latent infection. Other RNA- and protein-based assays detect lytic viral replication and can distinguish carcinoma-derived from lymphocyte-derived EBV in saliva or nasopharyngeal brushings. Analysis of blood using EBV viral load and serology reflects disease status and risk of progression. This review summarizes prior research in the context of basic virologic principles to provide a rational strategy for applying and interpreting EBV tests in various clinical settings. Such assays have been incorporated into standard clinical practice in selected settings such as diagnosis of primary infection and management of patients with immune dysfunction or nasopharyngeal carcinoma. As novel therapies are developed that target virus-infected cells or overcome the adverse effects of infection, laboratory testing becomes even more critical for determining when intervention is appropriate and the extent to which it has succeeded. PMID:18556771

  14. Assessment of the interlaboratory variability and robustness of JAK2V617F mutation assays: A study involving a consortium of 19 Italian laboratories

    PubMed Central

    Perricone, Margherita; Palandri, Francesca; Ottaviani, Emanuela; Angelini, Mario; Bagli, Laura; Bellesia, Enrica; Donati, Meris; Gemmati, Donato; Zucchini, Patrizia; Mancini, Stefania; Marchica, Valentina; Trubini, Serena; Matteis, Giovanna De; Zacomo, Silvia Di; Favarato, Mosè; Fioroni, Annamaria; Bolzonella, Caterina; Maccari, Giorgia; Navaglia, Filippo; Gatti, Daniela; Toffolatti, Luisa; Orlandi, Linda; Laloux, Vèronique; Manfrini, Marco; Galieni, Piero; Giannini, Barbara; Tieghi, Alessia; Barulli, Sara; Serino, Maria Luisa; Maccaferri, Monica; Scortechini, Anna Rita; Giuliani, Nicola; Vallisa, Daniele; Bonifacio, Massimiliano; Accorsi, Patrizia; Salbe, Cristina; Fazio, Vinicio; Gusella, Milena; Toffoletti, Eleonora; Salvucci, Marzia; Svaldi, Mirija; Gherlinzoni, Filippo; Cassavia, Francesca; Orsini, Francesco; Martinelli, Giovanni

    2017-01-01

    To date, a plenty of techniques for the detection of JAK2V617F is used over different laboratories, with substantial differences in specificity and sensitivity. Therefore, to provide reliable and comparable results, the standardization of molecular techniques is mandatory. A network of 19 centers was established to 1) evaluate the inter- and intra-laboratory variability in JAK2V617F quantification, 2) identify the most robust assay for the standardization of the molecular test and 3) allow consistent interpretation of individual patient analysis results. The study was conceived in 3 different rounds, in which all centers had to blindly test DNA samples with different JAK2V617F allele burden (AB) using both quantitative and qualitative assays. The positivity of samples with an AB < 1% was not detected by qualitative assays. Conversely, laboratories performing the quantitative approach were able to determine the expected JAK2V617F AB. Quantitative results were reliable across all mutation loads with moderate variability at low AB (0.1 and 1%; CV = 0.46 and 0.77, respectively). Remarkably, all laboratories clearly distinguished between the 0.1 and 1% mutated samples. In conclusion, a qualitative approach is not sensitive enough to detect the JAK2V617F mutation, especially at low AB. On the contrary, the ipsogen JAK2 MutaQuant CE-IVD kit resulted in a high, efficient and sensitive quantification detection of all mutation loads. This study sets the basis for the standardization of molecular techniques for JAK2V617F determination, which will require the employment of approved operating procedures and the use of certificated standards, such as the recent WHO 1st International Reference Panel for Genomic JAK2V617F. PMID:28427233

  15. Assessment of the interlaboratory variability and robustness of JAK2V617F mutation assays: A study involving a consortium of 19 Italian laboratories.

    PubMed

    Perricone, Margherita; Palandri, Francesca; Ottaviani, Emanuela; Angelini, Mario; Bagli, Laura; Bellesia, Enrica; Donati, Meris; Gemmati, Donato; Zucchini, Patrizia; Mancini, Stefania; Marchica, Valentina; Trubini, Serena; De Matteis, Giovanna; Di Zacomo, Silvia; Favarato, Mosè; Fioroni, Annamaria; Bolzonella, Caterina; Maccari, Giorgia; Navaglia, Filippo; Gatti, Daniela; Toffolatti, Luisa; Orlandi, Linda; Laloux, Vèronique; Manfrini, Marco; Galieni, Piero; Giannini, Barbara; Tieghi, Alessia; Barulli, Sara; Serino, Maria Luisa; Maccaferri, Monica; Scortechini, Anna Rita; Giuliani, Nicola; Vallisa, Daniele; Bonifacio, Massimiliano; Accorsi, Patrizia; Salbe, Cristina; Fazio, Vinicio; Gusella, Milena; Toffoletti, Eleonora; Salvucci, Marzia; Svaldi, Mirija; Gherlinzoni, Filippo; Cassavia, Francesca; Orsini, Francesco; Martinelli, Giovanni

    2017-05-16

    To date, a plenty of techniques for the detection of JAK2V617F is used over different laboratories, with substantial differences in specificity and sensitivity. Therefore, to provide reliable and comparable results, the standardization of molecular techniques is mandatory.A network of 19 centers was established to 1) evaluate the inter- and intra-laboratory variability in JAK2V617F quantification, 2) identify the most robust assay for the standardization of the molecular test and 3) allow consistent interpretation of individual patient analysis results. The study was conceived in 3 different rounds, in which all centers had to blindly test DNA samples with different JAK2V617F allele burden (AB) using both quantitative and qualitative assays.The positivity of samples with an AB < 1% was not detected by qualitative assays. Conversely, laboratories performing the quantitative approach were able to determine the expected JAK2V617F AB. Quantitative results were reliable across all mutation loads with moderate variability at low AB (0.1 and 1%; CV = 0.46 and 0.77, respectively). Remarkably, all laboratories clearly distinguished between the 0.1 and 1% mutated samples.In conclusion, a qualitative approach is not sensitive enough to detect the JAK2V617F mutation, especially at low AB. On the contrary, the ipsogen JAK2 MutaQuant CE-IVD kit resulted in a high, efficient and sensitive quantification detection of all mutation loads. This study sets the basis for the standardization of molecular techniques for JAK2V617F determination, which will require the employment of approved operating procedures and the use of certificated standards, such as the recent WHO 1st International Reference Panel for Genomic JAK2V617F.

  16. Missed detection of significant positive and negative shifts in gentamicin assay: implications for routine laboratory quality practices.

    PubMed

    Koerbin, Gus; Liu, Jiakai; Eigenstetter, Alex; Tan, Chin Hon; Badrick, Tony; Loh, Tze Ping

    2018-02-15

    A product recall was issued for the Roche/Hitachi Cobas Gentamicin II assays on 25 th May 2016 in Australia, after a 15 - 20% positive analytical shift was discovered. Laboratories were advised to employ the Thermo Fisher Gentamicin assay as an alternative. Following the reintroduction of the revised assay on 12 th September 2016, a second reagent recall was made on 20 th March 2017 after the discovery of a 20% negative analytical shift due to erroneous instrument adjustment factor. The practices of an index laboratory were examined to determine how the analytical shifts evaded detection by routine internal quality control (IQC) and external quality assurance (EQA) systems. The ability of the patient result-based approaches, including moving average (MovAvg) and moving sum of outliers (MovSO) approaches in detecting these shifts were examined. Internal quality control data of the index laboratory were acceptable prior to the product recall. The practice of adjusting IQC target following a change in assay method resulted in the missed negative shift when the revised Roche assay was reintroduced. While the EQA data of the Roche subgroup showed clear negative bias relative to other laboratory methods, the results were considered as possible 'matrix effect'. The MovAvg method detected the positive shift before the product recall. The MovSO did not detect the negative shift in the index laboratory but did so in another laboratory 5 days before the second product recall. There are gaps in current laboratory quality practices that leave room for analytical errors to evade detection.

  17. Mobile suitcase laboratory for rapid detection of Leishmania donovani using recombinase polymerase amplification assay.

    PubMed

    Mondal, Dinesh; Ghosh, Prakash; Khan, Md Anik Ashfaq; Hossain, Faria; Böhlken-Fascher, Susanne; Matlashewski, Greg; Kroeger, Axel; Olliaro, Piero; Abd El Wahed, Ahmed

    2016-05-13

    Leishmania donovani (LD) is a protozoan parasite transmitted to humans from sand flies, which causes Visceral Leishmaniasis (VL). Currently, the diagnosis is based on presence of the anti-LD antibodies and clinical symptoms. Molecular diagnosis would require real-time PCR, which is not easy to implement at field settings. In this study, we report on the development and testing of a recombinase polymerase amplification (RPA) assay for the detection of LD. A genomic DNA sample was applied to determine the assay analytical sensitivity. The cross-reactivity of the assay was tested by DNA of Leishmania spp. and of pathogens considered for differential diagnosis. The clinical performance of the assay was evaluated on LD positive and negative samples. All results were compared with real-time PCR. To allow the use of the assay at field settings, a mobile suitcase laboratory (56 × 45.5 × 26.5 cm) was developed and operated at the local hospital in Mymensingh, Bangladesh. The LD RPA assay detected equivalent to one LD genomic DNA. The assay was performed at constant temperature (42 °C) in 15 min. The RPA assay also detected other Leishmania species (L. major, L. aethiopica and L. infantum), but did not identify nucleic acid of other pathogens. Forty-eight samples from VL, asymptomatic and post-kala-azar dermal leishmaniasis subjects were detected positive and 48 LD-negative samples were negative by both LD RPA and real-time PCR assays, which indicates 100 % agreement. The suitcase laboratory was successfully operated at the local hospital by using a solar-powered battery. DNA extraction was performed by a novel magnetic bead based method (SpeedXtract), in which a simple fast lysis protocol was applied. Moreover, All reagents were cold-chain independent. The mobile suitcase laboratory using RPA is ideal for rapid sensitive and specific detection of LD especially at low resource settings and could contribute to VL control and elimination programmes.

  18. INNOVATIONS IN EQUIPMENT AND TECHNIQUES FOR THE BIOLOGY TEACHING LABORATORY.

    ERIC Educational Resources Information Center

    BARTHELEMY, RICHARD E.; AND OTHERS

    LABORATORY TECHNIQUES AND EQUIPMENT APPROPRIATE FOR TEACHING BIOLOGICAL SCIENCE CURRICULUM STUDY BIOLOGY ARE EMPHASIZED. MAJOR CATEGORIES INCLUDE (1) LABORATORY FACILITIES, (2) EQUIPMENT AND TECHNIQUES FOR CULTURE OF MICRO-ORGANISMS, (3) LABORATORY ANIMALS AND THEIR HOUSING, (4) TECHNIQUES FOR STUDYING PLANT GROWTH, (5) TECHNIQUES FOR STUDYING…

  19. Multi-laboratory evaluations of the performance of Catellicoccus marimammalium PCR assays developed to target gull fecal sources

    USGS Publications Warehouse

    Sinigalliano, Christopher D.; Ervin, Jared S.; Van De Werfhorst, Laurie C.; Badgley, Brian D.; Ballestée, Elisenda; Bartkowiaka, Jakob; Boehm, Alexandria B.; Byappanahalli, Muruleedhara N.; Goodwin, Kelly D.; Gourmelon, Michèle; Griffith, John; Holden, Patricia A.; Jay, Jenny; Layton, Blythe; Lee, Cheonghoon; Lee, Jiyoung; Meijer, Wim G.; Noble, Rachel; Raith, Meredith; Ryu, Hodon; Sadowsky, Michael J.; Schriewer, Alexander; Wang, Dan; Wanless, David; Whitman, Richard; Wuertz, Stefan; Santo Domingo, Jorge W.

    2013-01-01

    Here we report results from a multi-laboratory (n = 11) evaluation of four different PCR methods targeting the 16S rRNA gene of Catellicoccus marimammalium originally developed to detect gull fecal contamination in coastal environments. The methods included a conventional end-point PCR method, a SYBR® Green qPCR method, and two TaqMan® qPCR methods. Different techniques for data normalization and analysis were tested. Data analysis methods had a pronounced impact on assay sensitivity and specificity calculations. Across-laboratory standardization of metrics including the lower limit of quantification (LLOQ), target detected but not quantifiable (DNQ), and target not detected (ND) significantly improved results compared to results submitted by individual laboratories prior to definition standardization. The unit of measure used for data normalization also had a pronounced effect on measured assay performance. Data normalization to DNA mass improved quantitative method performance as compared to enterococcus normalization. The MST methods tested here were originally designed for gulls but were found in this study to also detect feces from other birds, particularly feces composited from pigeons. Sequencing efforts showed that some pigeon feces from California contained sequences similar to C. marimammalium found in gull feces. These data suggest that the prevalence, geographic scope, and ecology of C. marimammalium in host birds other than gulls require further investigation. This study represents an important first step in the multi-laboratory assessment of these methods and highlights the need to broaden and standardize additional evaluations, including environmentally relevant target concentrations in ambient waters from diverse geographic regions.

  20. Comparative field study: impact of laboratory assay variability on the assessment of recombinant factor IX Fc fusion protein (rFIXFc) activity.

    PubMed

    Sommer, Jurg M; Buyue, Yang; Bardan, Sara; Peters, Robert T; Jiang, Haiyan; Kamphaus, George D; Gray, Elaine; Pierce, Glenn F

    2014-11-01

    Due to variability in the one-stage clotting assay, the performance of new factor IX (FIX) products should be assessed in this assay. The objective of this field study was to evaluate the accuracy of measuring recombinant FIX Fc fusion protein (rFIXFc) activity in clinical haemostasis laboratories using the one-stage clotting assay. Human haemophilic donor plasma was spiked with rFIXFc or BeneFIX® at 0.80, 0.20, or 0.05 IU/ml based on label potency. Laboratories tested blinded samples using their routine one-stage assay and in-house FIX plasma standard. The mean spike recoveries for BeneFIX (n=30 laboratories) were 121 %, 144 %, and 168 % of expected at nominal 0.80, 0.20, and 0.05 IU/ml concentrations, respectively. Corresponding rFIXFc spike recoveries were 88 %, 107 %, and 132 % of expected, respectively. All BeneFIX concentrations were consistently overestimated by most laboratories. rFIXFc activity was reagent-dependent; ellagic acid and silica gave higher values than kaolin, which underestimated rFIXFc. BeneFIX demonstrated significantly reduced chromogenic assay activity relative to one-stage assay results and nominal activity, while rFIXFc activity was close to nominal activity at three concentrations with better dilution linearity than the typical one-stage assay. In conclusion, laboratory- and reagent-specific assay variabilities were revealed, with progressively higher variability at lower FIX concentrations. Non-parallelism against the FIX plasma standard was observed in all one-stage assays with rFIXFc and BeneFIX, leading to significant overestimation of FIX activity at lower levels and generally high inter-laboratory variability. Compared to the accuracy currently achieved in clinical laboratories when measuring other rFIX products, most laboratories measured rFIXFc activity with acceptable accuracy and reliability using routine one-stage assay methods and commercially available plasma standards.

  1. Laboratory procedures manual for the firefly luciferase assay for adenosine triphosphate (ATP)

    NASA Technical Reports Server (NTRS)

    Chappelle, E. W.; Picciolo, G. L.; Curtis, C. A.; Knust, E. A.; Nibley, D. A.; Vance, R. B.

    1975-01-01

    A manual on the procedures and instruments developed for the adenosine triphosphate (ATP) luciferase assay is presented. Data cover, laboratory maintenance, maintenance of bacterial cultures, bacteria measurement, reagents, luciferase procedures, and determination of microbal susceptibility to antibiotics.

  2. Image-based ELISA on an activated polypropylene microtest plate--a spectrophotometer-free low cost assay technique.

    PubMed

    Parween, Shahila; Nahar, Pradip

    2013-10-15

    In this communication, we report ELISA technique on an activated polypropylene microtest plate (APPµTP) as an illustrative example of a low cost diagnostic assay. Activated test zone in APPµTP binds a capture biomolecule through covalent linkage thereby, eliminating non-specific binding often prevalent in absorption based techniques. Efficacy of APPµTP is demonstrated by detecting human immunoglobulin G (IgG), human immunoglobulin E (IgE) and Aspergillus fumigatus antibody in patient's sera. Detection is done by taking the image of the assay solution by a desktop scanner and analyzing the color of the image. Human IgE quantification by color saturation in the image-based assay shows excellent correlation with absorbance-based assay (Pearson correlation coefficient, r=0.992). Significance of the relationship is seen from its p value which is 4.087e-11. Performance of APPµTP is also checked with respect to microtiter plate and paper-based ELISA. APPµTP can quantify an analyte as precisely as in microtiter plate with insignificant non-specific binding, a necessary prerequisite for ELISA assay. In contrast, paper-ELISA shows high non-specific binding in control sera (false positive). Finally, we have carried out ELISA steps on APPµTP by ultrasound waves on a sonicator bath and the results show that even in 8 min, it can convincingly differentiate a test sample from a control sample. In short, spectrophotometer-free image-based miniaturized ELISA on APPµTP is precise, reliable, rapid, and sensitive and could be a good substitute for conventional immunoassay procedures widely used in clinical and research laboratories. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Measurements for 8 common analytes in native sera identify inadequate standardization among 6 routine laboratory assays.

    PubMed

    Stepman, Hedwig C M; Tiikkainen, Ulla; Stöckl, Dietmar; Vesper, Hubert W; Edwards, Selvin H; Laitinen, Harri; Pelanti, Jonna; Thienpont, Linda M

    2014-06-01

    External quality assessment (EQA) with commutable samples is essential for assessing the quality of assays performed by laboratories, particularly when the emphasis is on their standardization status and interchangeability of results. We used a panel of 20 fresh-frozen single-donation serum samples to assess assays for the measurement of creatinine, glucose, phosphate, uric acid, total cholesterol, HDL cholesterol, LDL cholesterol, and triglycerides. The commercial random access platforms included: Abbott Architect, Beckman Coulter AU, Ortho Vitros, Roche Cobas, Siemens Advia, and Thermo Scientific Konelab. The assessment was done at the peer group level and by comparison against the all-method trimmed mean or reference method values, where available. The considered quality indicators were intraassay imprecision, combined imprecision (including sample-matrix interference), bias, and total error. Fail/pass decisions were based on limits reflecting state-of-the-art performance, but also limits related to biological variation. Most assays showed excellent peer performance attributes, except for HDL- and LDL cholesterol. Cases in which individual assays had biases exceeding the used limits were the Siemens Advia creatinine (-4.2%), Ortho Vitros phosphate (8.9%), Beckman Coulter AU triglycerides (5.4%), and Thermo Scientific Konelab uric acid (6.4%), which lead to considerable interassay discrepancies. Additionally, large laboratory effects were observed that caused interlaboratory differences of >30%. The design of the EQA study was well suited for monitoring different quality attributes of assays performed in daily laboratory practice. There is a need for improvement, even for simple clinical chemistry analytes. In particular, the interchangeability of results remains jeopardized both by assay standardization issues and individual laboratory effects. © 2014 The American Association for Clinical Chemistry.

  4. Laboratory assessment of Activated Protein C Resistance/Factor V-Leiden and performance characteristics of a new quantitative assay.

    PubMed

    Amiral, Jean; Vissac, Anne Marie; Seghatchian, Jerard

    2017-12-01

    Activated Protein C Resistance is mainly associated to a factor V mutation (RQ506), which induces a deficient inactivation of activated factor V by activated protein C, and is associated to an increased risk of venous and arterial thrombosis in affected individuals, caused by the prolonged activated factor V survival. Its prevalence is mainly in Caucasians (about 5%), and this mutation is absent in Africans and Asians. Presence of Factor V-Leiden is usually evidenced with clotting methods, using a two-step APTT assay performed without or with APC: prolongation of blood coagulation time is decreased if this factor is present. The R506Q Factor V-Leiden mutation is now usually characterized using molecular biology, and this technique tends to become the first intention assay for characterization of patients. Both techniques are qualitative, and allow classifying tested individuals as heterozygotes or homozygotes for the mutation, when present. A new quantitative assay for Factor V-Leiden, using a one-step clotting method, has been developed, and designed with highly purified human coagulation proteins. Clotting is triggered with human Factor Xa, in presence of calcium and phospholipids (mixture which favours APC action over clotting process). Diluted tested plasma, is supplemented with a clotting mixture containing human fibrinogen, prothrombin, and protein S at a constant concentration. APC is added, and clotting is initiated with calcium. Calibration is performed with a pool of plasmas from patients carrying the R506Q Factor V mutation, and its mixtures with normal plasma. Homozygous patients have clotting times of about <40sec; heterozygous patients have clotting times of about 40-60sec and normal individuals yield clotting times >70sec. Factor V-Leiden concentration is usually >75% in homozygous patients, 30-60% in heterozygous patients and below 5% in normal. The assay is insensitive to clotting factor deficiencies (II, VII, VIII: C, IX, X), dicoumarol or heparin

  5. Inter-laboratory consistency and variability in the buccal micronucleus cytome assay depends on biomarker scored and laboratory experience: results from the HUMNxl international inter-laboratory scoring exercise.

    PubMed

    Bolognesi, Claudia; Knasmueller, Siegfried; Nersesyan, Armen; Roggieri, Paola; Ceppi, Marcello; Bruzzone, Marco; Blaszczyk, Ewa; Mielzynska-Svach, Danuta; Milic, Mirta; Bonassi, Stefano; Benedetti, Danieli; Da Silva, Juliana; Toledo, Raphael; Salvadori, Daisy Maria Fávero; Groot de Restrepo, Helena; Filipic, Metka; Hercog, Klara; Aktas, Ayça; Burgaz, Sema; Kundi, Michael; Grummt, Tamara; Thomas, Philip; Hor, Maryam; Escudero-Fung, Maria; Holland, Nina; Fenech, Michael

    2017-03-01

    The buccal micronucleus cytome (BMNcyt) assay in uncultured exfoliated epithelial cells from oral mucosa is widely applied in biomonitoring human exposures to genotoxic agents and is also proposed as a suitable test for prescreening and follow-up of precancerous oral lesions. The main limitation of the assay is the large variability observed in the baseline values of micronuclei (MNi) and other nuclear anomalies mainly related to different scoring criteria. The aim of this international collaborative study, involving laboratories with different level of experience, was to evaluate the inter- and intra-laboratory variations in the BMNcyt parameters, using recently implemented guidelines, in scoring cells from the same pooled samples obtained from healthy subjects (control group) and from cancer patients undergoing radiotherapy (treated group). The results indicate that all laboratories correctly discriminated samples from the two groups by a significant increase of micronucleus (MN) and nuclear bud (NBUD) frequencies and differentiated binucleated (BN) cells, associated with the exposure to ionizing radiation. The experience of the laboratories was shown to play an important role in the identification of the different cell types and nuclear anomalies. MN frequency in differentiated mononucleated (MONO) and BN cells showed the greatest consistency among the laboratories and low variability was also detected in the frequencies of MONO and BN cells. A larger variability was observed in classifying the different cell types, indicating the subjectivity in the interpretation of some of the scoring criteria while reproducibility of the results between scoring sessions was very good. An inter-laboratory calibration exercise is strongly recommended before starting studies with BMNcyt assay involving multiple research centers. © The Author 2016. Published by Oxford University Press on behalf of the UK Environmental Mutagen Society. All rights reserved. For permissions

  6. Assay of Radon and Radium in Water: Techniques Developed at SNO

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farine, Jacques

    Water assay techniques developed for measuring 222Rn, 226Ra and 224Ra in the SNO detector are presented. Recent upgrades to improve the performance of the techniques and to increase the sensitivity to lower levels are discussed.

  7. Electrochemical Assay of Gold-Plating Solutions

    NASA Technical Reports Server (NTRS)

    Chiodo, R.

    1982-01-01

    Gold content of plating solution is assayed by simple method that required only ordinary electrochemical laboratory equipment and materials. Technique involves electrodeposition of gold from solution onto electrode, the weight gain of which is measured. Suitable fast assay methods are economically and practically necessary in electronics and decorative-plating industries. If gold content in plating bath is too low, poor plating may result, with consequent economic loss to user.

  8. Computer-assisted enzyme immunoassays and simplified immunofluorescence assays: applications for the diagnostic laboratory and the veterinarian's office.

    PubMed

    Jacobson, R H; Downing, D R; Lynch, T J

    1982-11-15

    A computer-assisted enzyme-linked immunosorbent assay (ELISA) system, based on kinetics of the reaction between substrate and enzyme molecules, was developed for testing large numbers of sera in laboratory applications. Systematic and random errors associated with conventional ELISA technique were identified leading to results formulated on a statistically validated, objective, and standardized basis. In a parallel development, an inexpensive system for field and veterinary office applications contained many of the qualities of the computer-assisted ELISA. This system uses a fluorogenic indicator (rather than the enzyme-substrate interaction) in a rapid test (15 to 20 minutes' duration) which promises broad application in serodiagnosis.

  9. Agreement between allergen-specific IgE assays and ensuing immunotherapy recommendations from four commercial laboratories in the USA

    PubMed Central

    Plant, Jon D; Neradelik, Moni B; Polissar, Nayak L; Fadok, Valerie A; Scott, Brian A

    2014-01-01

    Background Canine allergen-specific IgE assays in the USA are not subjected to an independent laboratory reliability monitoring programme. Hypothesis/Objectives The aim of this study was to evaluate the agreement of diagnostic results and treatment recommendations of four serum IgE assays commercially available in the USA. Methods Replicate serum samples from 10 atopic dogs were submitted to each of four laboratories for allergen-specific IgE assays (ACTT®, VARL Liquid Gold, ALLERCEPT® and Greer® Aller-g-complete®). The interlaboratory agreement of standard, regional panels and ensuing treatment recommendations were analysed with the kappa statistic (κ) to account for agreement that might occur merely by chance. Six comparisons of pairs of laboratories and overall agreement among laboratories were analysed for ungrouped allergens (as tested) and also with allergens grouped according to reported cross-reactivity and taxonomy. Results The overall chance-corrected agreement of the positive/negative test results for ungrouped and grouped allergens was slight (κ = 0.14 and 0.13, respectively). Subset analysis of the laboratory pair with the highest level of diagnostic agreement (κ = 0.36) found slight agreement (κ = 0.13) for ungrouped plants and fungi, but substantial agreement (κ = 0.71) for ungrouped mites. The overall agreement of the treatment recommendations was slight (κ = 0.11). Altogether, 85.1% of ungrouped allergen treatment recommendations were unique to one laboratory or another. Conclusions and clinical importance Our study indicated that the choice of IgE assay may have a major influence on the positive/negative results and ensuing treatment recommendations. PMID:24461034

  10. Complementary Spectroscopic Assays for Investigating Protein-Ligand Binding Activity: A Project for the Advanced Chemistry Laboratory

    ERIC Educational Resources Information Center

    Mascotti, David P.; Waner, Mark J.

    2010-01-01

    A protein-ligand binding, guided-inquiry laboratory project with potential application across the advanced undergraduate curriculum is described. At the heart of the project are fluorescence and spectrophotometric assays utilizing biotin-4-fluorescein and streptavidin. The use of the same stock solutions for an assay that may be examined by two…

  11. Betrixaban: Impact on Routine and Specific Coagulation Assays-A Practical Laboratory Guide.

    PubMed

    Siriez, Romain; Evrard, Jonathan; Dogné, Jean-Michel; Pochet, Lionel; Gheldof, Damien; Chatelain, Bernard; Mullier, François; Douxfils, Jonathan

    2018-06-11

     Betrixaban is a novel direct oral factor Xa inhibitor approved by the Food and Drug Administration for prophylaxis of venous thromboembolism in adult patients hospitalized for an acute illness at risk for thromboembolic complications. Assessment of the anti-coagulant effect of betrixaban may be useful in some situations. Also, clinicians need to know how routine coagulation assays are influenced.  The aim of this study is to determine which coagulation assay(s) should be used to assess the impact of betrixaban on haemostasis and provide laboratory guidance for their interpretation.  Betrixaban was spiked at final concentrations ranging from 0 to 250 ng/mL in platelet-poor plasma. Different reagents from several manufacturers were tested and the impact of betrixaban on pro-thrombin time (PT), activated partial thromboplastin time (aPTT), dilute Russel viper venom time (dRVV-T), chromogenic anti-Xa assays, thrombin generation assay (TGA), and a large panel of haemostasis diagnostic tests has been assessed.  A concentration-dependent prolongation of aPTT, PT and dRVV-T is observed. The sensitivity mainly depends on the reagent. Chromogenic anti-Xa assays show high sensitivity depending on the reagent and/or the methodology. These assays applicable for other direct factor Xa inhibitors have to be adapted to obtain a relevant range of measurement. TGA may also be attractive to assess the anti-coagulant activity of betrixaban.  Adapted chromogenic anti-Xa assays are the most appropriate assays to estimate the concentration of betrixaban. Betrixaban significantly affects several haemostasis diagnostic tests and this needs to be taken into consideration when requesting and interpreting such tests. Schattauer GmbH Stuttgart.

  12. A Technique Oriented Freshman Laboratory Program

    ERIC Educational Resources Information Center

    Palma, R. J., Sr.

    1975-01-01

    Describes a program built on the philosophy that laboratory exercises were to be exclusively reserved for those concepts which could not be taught more effectively by other pedagogical techniques. Presents faculty and student criticisms of the program. (GS)

  13. Inter-laboratory assessment of a harmonized zebrafish developmental toxicology assay - progress report on phase I.

    PubMed

    Gustafson, A-L; Stedman, D B; Ball, J; Hillegass, J M; Flood, A; Zhang, C X; Panzica-Kelly, J; Cao, J; Coburn, A; Enright, B P; Tornesi, M B; Hetheridge, M; Augustine-Rauch, K A

    2012-04-01

    This report provides a progress update of a consortium effort to develop a harmonized zebrafish developmental toxicity assay. Twenty non-proprietary compounds (10 animal teratogens and 10 animal non-teratogens) were evaluated blinded in 4 laboratories. Zebrafish embryos from pond-derived and cultivated strain wild types were exposed to the test compounds for 5 days and subsequently evaluated for lethality and morphological changes. Each of the testing laboratories achieved similar overall concordance to the animal data (60-70%). Subsequent optimization procedures to improve the overall concordance focused on compound formulation and test concentration adjustments, chorion permeation and number of replicates. These optimized procedures were integrated into a revised protocol and all compounds were retested in one lab using embryos from pond-derived zebrafish and achieved 85% total concordance. To further assess assay performance, a study of additional compounds is currently in progress at two laboratories using embryos from pond-derived and cultivated-strain wild type zebrafish. Copyright © 2011 Elsevier Inc. All rights reserved.

  14. Agreement between allergen-specific IgE assays and ensuing immunotherapy recommendations from four commercial laboratories in the USA.

    PubMed

    Plant, Jon D; Neradelik, Moni B; Polissar, Nayak L; Fadok, Valerie A; Scott, Brian A

    2014-02-01

    Canine allergen-specific IgE assays in the USA are not subjected to an independent laboratory reliability monitoring programme. The aim of this study was to evaluate the agreement of diagnostic results and treatment recommendations of four serum IgE assays commercially available in the USA. Replicate serum samples from 10 atopic dogs were submitted to each of four laboratories for allergen-specific IgE assays (ACTT(®) , VARL Liquid Gold, ALLERCEPT(®) and Greer(®) Aller-g-complete(®) ). The interlaboratory agreement of standard, regional panels and ensuing treatment recommendations were analysed with the kappa statistic (κ) to account for agreement that might occur merely by chance. Six comparisons of pairs of laboratories and overall agreement among laboratories were analysed for ungrouped allergens (as tested) and also with allergens grouped according to reported cross-reactivity and taxonomy. The overall chance-corrected agreement of the positive/negative test results for ungrouped and grouped allergens was slight (κ = 0.14 and 0.13, respectively). Subset analysis of the laboratory pair with the highest level of diagnostic agreement (κ = 0.36) found slight agreement (κ = 0.13) for ungrouped plants and fungi, but substantial agreement (κ = 0.71) for ungrouped mites. The overall agreement of the treatment recommendations was slight (κ = 0.11). Altogether, 85.1% of ungrouped allergen treatment recommendations were unique to one laboratory or another. Our study indicated that the choice of IgE assay may have a major influence on the positive/negative results and ensuing treatment recommendations. © 2014 The Authors. Veterinary Dermatology published by John Wiley & Sons Ltd on behalf of the ESVD and the ACVD.

  15. Applicability of the DPPH assay for evaluating the antioxidant capacity of food additives - inter-laboratory evaluation study -.

    PubMed

    Shimamura, Tomoko; Sumikura, Yoshihiro; Yamazaki, Takeshi; Tada, Atsuko; Kashiwagi, Takehiro; Ishikawa, Hiroya; Matsui, Toshiro; Sugimoto, Naoki; Akiyama, Hiroshi; Ukeda, Hiroyuki

    2014-01-01

    An inter-laboratory evaluation study was conducted in order to evaluate the antioxidant capacity of food additives by using a 1,1-diphenyl-2-picrylhydrazyl (DPPH) assay. Four antioxidants used as existing food additives (i.e., tea extract, grape seed extract, enju extract, and d-α-tocopherol) and 6-hydroxy-2,5,7,8-tetramethylchroman-2-carboxylic acid (Trolox) were used as analytical samples, and 14 laboratories participated in this study. The repeatability relative standard deviation (RSD(r)) of the IC50 of Trolox, four antioxidants, and the Trolox equivalent antioxidant capacity (TEAC) were 1.8-2.2%, 2.2-2.9%, and 2.1-2.5%, respectively. Thus, the proposed DPPH assay showed good performance within the same laboratory. The reproducibility relative standard deviation (RSD(R)) of IC50 of Trolox, four antioxidants, and TEAC were 4.0-7.9%, 6.0-11%, and 3.7-9.3%, respectively. The RSD(R)/RSD(r) values of TEAC were lower than, or nearly equal to, those of IC50 of the four antioxidants, suggesting that the use of TEAC was effective for reducing the variance among the laboratories. These results showed that the proposed DPPH assay could be used as a standard method to evaluate the antioxidant capacity of food additives.

  16. Analytic Validation of Immunohistochemical Assays: A Comparison of Laboratory Practices Before and After Introduction of an Evidence-Based Guideline.

    PubMed

    Fitzgibbons, Patrick L; Goldsmith, Jeffrey D; Souers, Rhona J; Fatheree, Lisa A; Volmar, Keith E; Stuart, Lauren N; Nowak, Jan A; Astles, J Rex; Nakhleh, Raouf E

    2017-09-01

    - Laboratories must demonstrate analytic validity before any test can be used clinically, but studies have shown inconsistent practices in immunohistochemical assay validation. - To assess changes in immunohistochemistry analytic validation practices after publication of an evidence-based laboratory practice guideline. - A survey on current immunohistochemistry assay validation practices and on the awareness and adoption of a recently published guideline was sent to subscribers enrolled in one of 3 relevant College of American Pathologists proficiency testing programs and to additional nonsubscribing laboratories that perform immunohistochemical testing. The results were compared with an earlier survey of validation practices. - Analysis was based on responses from 1085 laboratories that perform immunohistochemical staining. Of 1057 responses, 65.4% (691) were aware of the guideline recommendations before this survey was sent and 79.9% (550 of 688) of those have already adopted some or all of the recommendations. Compared with the 2010 survey, a significant number of laboratories now have written validation procedures for both predictive and nonpredictive marker assays and specifications for the minimum numbers of cases needed for validation. There was also significant improvement in compliance with validation requirements, with 99% (100 of 102) having validated their most recently introduced predictive marker assay, compared with 74.9% (326 of 435) in 2010. The difficulty in finding validation cases for rare antigens and resource limitations were cited as the biggest challenges in implementing the guideline. - Dissemination of the 2014 evidence-based guideline validation practices had a positive impact on laboratory performance; some or all of the recommendations have been adopted by nearly 80% of respondents.

  17. Can a Point-of-Care Troponin I Assay be as Good as a Central Laboratory Assay? A MIDAS Investigation

    PubMed Central

    Diercks, Deborah; Birkhahn, Robert; Singer, Adam J.; Hollander, Judd E.; Nowak, Richard; Safdar, Basmah; Miller, Chadwick D.; Peberdy, Mary; Counselman, Francis; Chandra, Abhinav; Kosowsky, Joshua; Neuenschwander, James; Schrock, Jon; Lee-Lewandrowski, Elizabeth; Arnold, William; Nagurney, John

    2016-01-01

    Background We aimed to compare the diagnostic accuracy of the Alere Triage Cardio3 Tropinin I (TnI) assay (Alere, Inc., USA) and the PathFast cTnI-II (Mitsubishi Chemical Medience Corporation, Japan) against the central laboratory assay Singulex Erenna TnI assay (Singulex, USA). Methods Using the Markers in the Diagnosis of Acute Coronary Syndromes (MIDAS) study population, we evaluated the ability of three different assays to identify patients with acute myocardial infarction (AMI). The MIDAS dataset, described elsewhere, is a prospective multicenter dataset of emergency department (ED) patients with suspected acute coronary syndrome (ACS) and a planned objective myocardial perfusion evaluation. Myocardial infarction (MI) was diagnosed by central adjudication. Results The C-statistic with 95% confidence intervals (CI) for diagnosing MI by using a common population (n=241) was 0.95 (0.91-0.99), 0.95 (0.91-0.99), and 0.93 (0.89-0.97) for the Triage, Singulex, and PathFast assays, respectively. Of samples with detectable troponin, the absolute values had high Pearson (RP) and Spearman (RS) correlations and were RP =0.94 and RS=0.94 for Triage vs Singulex, RP =0.93 and RS=0.85 for Triage vs PathFast, and RP =0.89 and RS=0.73 for PathFast vs Singulex. Conclusions In a single comparative population of ED patients with suspected ACS, the Triage Cardio3 TnI, PathFast, and Singulex TnI assays provided similar diagnostic performance for MI. PMID:27374704

  18. Can a Point-of-Care Troponin I Assay be as Good as a Central Laboratory Assay? A MIDAS Investigation.

    PubMed

    Peacock, W Frank; Diercks, Deborah; Birkhahn, Robert; Singer, Adam J; Hollander, Judd E; Nowak, Richard; Safdar, Basmah; Miller, Chadwick D; Peberdy, Mary; Counselman, Francis; Chandra, Abhinav; Kosowsky, Joshua; Neuenschwander, James; Schrock, Jon; Lee-Lewandrowski, Elizabeth; Arnold, William; Nagurney, John

    2016-09-01

    We aimed to compare the diagnostic accuracy of the Alere Triage Cardio3 Tropinin I (TnI) assay (Alere, Inc., USA) and the PathFast cTnI-II (Mitsubishi Chemical Medience Corporation, Japan) against the central laboratory assay Singulex Erenna TnI assay (Singulex, USA). Using the Markers in the Diagnosis of Acute Coronary Syndromes (MIDAS) study population, we evaluated the ability of three different assays to identify patients with acute myocardial infarction (AMI). The MIDAS dataset, described elsewhere, is a prospective multicenter dataset of emergency department (ED) patients with suspected acute coronary syndrome (ACS) and a planned objective myocardial perfusion evaluation. Myocardial infarction (MI) was diagnosed by central adjudication. The C-statistic with 95% confidence intervals (CI) for diagnosing MI by using a common population (n=241) was 0.95 (0.91-0.99), 0.95 (0.91-0.99), and 0.93 (0.89-0.97) for the Triage, Singulex, and PathFast assays, respectively. Of samples with detectable troponin, the absolute values had high Pearson (R(P)) and Spearman (R(S)) correlations and were R(P)=0.94 and R(S)=0.94 for Triage vs Singulex, R(P)=0.93 and R(S)=0.85 for Triage vs PathFast, and R(P)=0.89 and R(S)=0.73 for PathFast vs Singulex. In a single comparative population of ED patients with suspected ACS, the Triage Cardio3 TnI, PathFast, and Singulex TnI assays provided similar diagnostic performance for MI.

  19. Determination of serum hCG levels by radioreactor assay in the clinical laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boyko, W.L.

    1979-09-01

    The radioreceptorassay (RRA) has been used for measuring human chorionic gonadotropin (hCG) in sera from 751 individuals. The RRA is shown to be sensitive (98%) and specific (99.8%) in detecting hCG in a wide variety of conditions, including normal pregnancy and threatened or missed abortions. As a rapid qualitative or semiquantitative assay for hCG, the RRA is a valuable adjunct in the laboratory to less sensitive tests for hCG. Variation among different quantitative assays for hCG is examined, and it is concluded that the same assay system should be used for monitoring hCG levels in a single individual over amore » period of time in order to avoid inconsistent results. Application of the quantitative RRA for hCG in detecting the midcycle luteinizing hormone surge in infertillity is also presented.« less

  20. An Enzyme-Free Signal Amplification Technique for Ultrasensitive Colorimetric Assay of Disease Biomarkers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ye, Haihang; Yang, Kuikun; Tao, Jing

    Enzyme-based colorimetric assays have been widely used in research labs and clinical diagnosis for decades. Nevertheless, as constrained by the performance of enzymes, their detection sensitivity has not been substantially improved in recent years, which inhibits many critical applications such as early detection of cancers. In this work, we demonstrate an enzyme-free signal amplification technique, based on gold vesicles encapsulated with Pd-Ir nanoparticles as peroxidase mimics, for colorimetric assay of disease biomarkers with significantly enhanced sensitivity. This technique overcomes the intrinsic limitations of enzymes, thanks to the superior catalytic efficiency of peroxidase mimics and the efficient loading and release ofmore » these mimics. Using human prostate surface antigen as a model biomarker, we demonstrated that the enzyme-free assay could reach a limit of detection at the femtogram/mL level, which is over 10 3-fold lower than that of conventional enzyme-based assay when the same antibodies and similar procedure were used.« less

  1. An Enzyme-Free Signal Amplification Technique for Ultrasensitive Colorimetric Assay of Disease Biomarkers

    DOE PAGES

    Ye, Haihang; Yang, Kuikun; Tao, Jing; ...

    2017-01-30

    Enzyme-based colorimetric assays have been widely used in research labs and clinical diagnosis for decades. Nevertheless, as constrained by the performance of enzymes, their detection sensitivity has not been substantially improved in recent years, which inhibits many critical applications such as early detection of cancers. In this work, we demonstrate an enzyme-free signal amplification technique, based on gold vesicles encapsulated with Pd-Ir nanoparticles as peroxidase mimics, for colorimetric assay of disease biomarkers with significantly enhanced sensitivity. This technique overcomes the intrinsic limitations of enzymes, thanks to the superior catalytic efficiency of peroxidase mimics and the efficient loading and release ofmore » these mimics. Using human prostate surface antigen as a model biomarker, we demonstrated that the enzyme-free assay could reach a limit of detection at the femtogram/mL level, which is over 10 3-fold lower than that of conventional enzyme-based assay when the same antibodies and similar procedure were used.« less

  2. Differential sensitivity of von Willebrand factor (VWF) 'activity' assays to large and small VWF molecular weight forms: a cross-laboratory study comparing ristocetin cofactor, collagen-binding and mAb-based assays.

    PubMed

    Favaloro, E J; Bonar, R; Chapman, K; Meiring, M; Funk Adcock, D

    2012-06-01

    von Willebrand disease (VWD), the most common inherited bleeding disorder, is caused by deficiencies and/or defects in von Willebrand factor (VWF). An effective diagnostic and VWD typing strategy requires plasma testing for factor VIII, and VWF antigen plus one or more VWF 'activity' assays. VWF activity is classically assessed by using VWF ristocetin cofactor activity (VWF:RCo), although VWF collagen-binding (VWF:CB) and VWF mAb-based (VWF activity [VWF:Act]) assays are used by some laboratories. To perform a cross-laboratory study to specifically evaluate these three VWF activity assays for comparative sensitivity to loss of high molecular weight (HMW) VWF, representing the form of VWF that is most functionally active and that is absent in some types of VWD, namely 2A and 2B. A set of eight samples, including six selectively representing stepwise reduction in HMW VWF, were tested by 51 different laboratories using a variety of assays. The combined data showed that the VWF:CB and VWF:RCo assays had higher sensitivity to the loss of HMW VWF than did the VWF:Act assay. Moreover, within-method analysis identified better HMW VWF sensitivity of some VWF:CB assays than of others, with all VWF:CB assays still showing better sensitivity than the VWF:Act assay. Differences were also identified between VWF:RCo methodologies on the basis of either platelet aggregometry or as performed on automated analyzers. We believe that these results have significant clinical implications for the diagnosis of VWD and monitoring of its therapy, as well as for the future diagnosis and therapy monitoring of thrombotic thrombocytopenic purpura. © 2012 International Society on Thrombosis and Haemostasis.

  3. Teaching about citric acid cycle using plant mitochondrial preparations: Some assays for use in laboratory courses*.

    PubMed

    Vicente, Joaquim A F; Gomes-Santos, Carina S S; Sousa, Ana Paula M; Madeira, Vítor M C

    2005-03-01

    Potato tubers and turnip roots were used to prepare purified mitochondria for laboratory practical work in the teaching of the citric acid cycle (TCA cycle). Plant mitochondria are particularly advantageous over the animal fractions to demonstrate the TCA cycle enzymatic steps, by using simple techniques to measure O(2) consumption and transmembrane potential (ΔΨ). The several TCA cycle intermediates induce specific enzyme activities, which can be identified by respiratory parameters. Such a strategy is also used to evidence properties of the TCA cycle enzymes: ADP stimulation of isocitrate dehydrogenase and α-ketoglutarate dehydrogenase; activation by citrate of downstream oxidation steps, e.g. succinate dehydrogenase; and regulation of the activity of isocitrate dehydrogenase by citrate action on the citrate/isocitrate carrier. Furthermore, it has been demonstrated that, in the absence of exogenous Mg(2+) , isocitrate-dependent respiration favors the alternative oxidase pathway, as judged by changes of the ADP/O elicited by the inhibitor n-propyl galate. These are some examples of assays related with TCA cycle intermediates we can use in laboratory courses. Copyright © 2005 International Union of Biochemistry and Molecular Biology, Inc.

  4. Assessment of an ELISA Laboratory Exercise

    ERIC Educational Resources Information Center

    Robinson, David L.; Lau, Joann M.

    2012-01-01

    The enzyme-linked immunosorbent assay (ELISA) is a powerful immunological technique for quantifying small amounts of compounds and has been used in research and clinical settings for years. Although there are laboratory exercises developed to introduce the ELISA technique to students, their ability to promote student learning has not been…

  5. Glucose-6-phosphate dehydrogenase laboratory assay: How, when, and why?

    PubMed

    Minucci, Angelo; Giardina, Bruno; Zuppi, Cecilia; Capoluongo, Ettore

    2009-01-01

    Glucose 6-phosphate dehydrogenase (G6PD) deficiency is the most common defect of red blood cells. Although some different laboratory techniques or methods are employed for the biochemical screening, a strict relationship between biochemists, clinicians, and molecular biologists is necessary for a definitive diagnosis. This article represents an overview on the current laboratory tests finalized to the screening or to the definitive diagnosis of G6PD-deficiency, underlying the problems regarding the biochemical and molecular identification of heterozygote females other than those regarding the standardization of the clinical and laboratory diagnostic procedures. Finally, this review is aimed to give a flow-chart for the complete diagnostic approach of G6PD-deficiency.

  6. Comet assay in reconstructed 3D human epidermal skin models--investigation of intra- and inter-laboratory reproducibility with coded chemicals.

    PubMed

    Reus, Astrid A; Reisinger, Kerstin; Downs, Thomas R; Carr, Gregory J; Zeller, Andreas; Corvi, Raffaella; Krul, Cyrille A M; Pfuhler, Stefan

    2013-11-01

    Reconstructed 3D human epidermal skin models are being used increasingly for safety testing of chemicals. Based on EpiDerm™ tissues, an assay was developed in which the tissues were topically exposed to test chemicals for 3h followed by cell isolation and assessment of DNA damage using the comet assay. Inter-laboratory reproducibility of the 3D skin comet assay was initially demonstrated using two model genotoxic carcinogens, methyl methane sulfonate (MMS) and 4-nitroquinoline-n-oxide, and the results showed good concordance among three different laboratories and with in vivo data. In Phase 2 of the project, intra- and inter-laboratory reproducibility was investigated with five coded compounds with different genotoxicity liability tested at three different laboratories. For the genotoxic carcinogens MMS and N-ethyl-N-nitrosourea, all laboratories reported a dose-related and statistically significant increase (P < 0.05) in DNA damage in every experiment. For the genotoxic carcinogen, 2,4-diaminotoluene, the overall result from all laboratories showed a smaller, but significant genotoxic response (P < 0.05). For cyclohexanone (CHN) (non-genotoxic in vitro and in vivo, and non-carcinogenic), an increase compared to the solvent control acetone was observed only in one laboratory. However, the response was not dose related and CHN was judged negative overall, as was p-nitrophenol (p-NP) (genotoxic in vitro but not in vivo and non-carcinogenic), which was the only compound showing clear cytotoxic effects. For p-NP, significant DNA damage generally occurred only at doses that were substantially cytotoxic (>30% cell loss), and the overall response was comparable in all laboratories despite some differences in doses tested. The results of the collaborative study for the coded compounds were generally reproducible among the laboratories involved and intra-laboratory reproducibility was also good. These data indicate that the comet assay in EpiDerm™ skin models is a

  7. Comet assay in reconstructed 3D human epidermal skin models—investigation of intra- and inter-laboratory reproducibility with coded chemicals

    PubMed Central

    Pfuhler, Stefan

    2013-01-01

    Reconstructed 3D human epidermal skin models are being used increasingly for safety testing of chemicals. Based on EpiDerm™ tissues, an assay was developed in which the tissues were topically exposed to test chemicals for 3h followed by cell isolation and assessment of DNA damage using the comet assay. Inter-laboratory reproducibility of the 3D skin comet assay was initially demonstrated using two model genotoxic carcinogens, methyl methane sulfonate (MMS) and 4-nitroquinoline-n-oxide, and the results showed good concordance among three different laboratories and with in vivo data. In Phase 2 of the project, intra- and inter-laboratory reproducibility was investigated with five coded compounds with different genotoxicity liability tested at three different laboratories. For the genotoxic carcinogens MMS and N-ethyl-N-nitrosourea, all laboratories reported a dose-related and statistically significant increase (P < 0.05) in DNA damage in every experiment. For the genotoxic carcinogen, 2,4-diaminotoluene, the overall result from all laboratories showed a smaller, but significant genotoxic response (P < 0.05). For cyclohexanone (CHN) (non-genotoxic in vitro and in vivo, and non-carcinogenic), an increase compared to the solvent control acetone was observed only in one laboratory. However, the response was not dose related and CHN was judged negative overall, as was p-nitrophenol (p-NP) (genotoxic in vitro but not in vivo and non-carcinogenic), which was the only compound showing clear cytotoxic effects. For p-NP, significant DNA damage generally occurred only at doses that were substantially cytotoxic (>30% cell loss), and the overall response was comparable in all laboratories despite some differences in doses tested. The results of the collaborative study for the coded compounds were generally reproducible among the laboratories involved and intra-laboratory reproducibility was also good. These data indicate that the comet assay in EpiDerm™ skin models is a

  8. Intra-/inter-laboratory validation study on reactive oxygen species assay for chemical photosafety evaluation using two different solar simulators.

    PubMed

    Onoue, Satomi; Hosoi, Kazuhiro; Toda, Tsuguto; Takagi, Hironori; Osaki, Naoto; Matsumoto, Yasuhiro; Kawakami, Satoru; Wakuri, Shinobu; Iwase, Yumiko; Yamamoto, Toshinobu; Nakamura, Kazuichi; Ohno, Yasuo; Kojima, Hajime

    2014-06-01

    A previous multi-center validation study demonstrated high transferability and reliability of reactive oxygen species (ROS) assay for photosafety evaluation. The present validation study was undertaken to verify further the applicability of different solar simulators and assay performance. In 7 participating laboratories, 2 standards and 42 coded chemicals, including 23 phototoxins and 19 non-phototoxic drugs/chemicals, were assessed by the ROS assay using two different solar simulators (Atlas Suntest CPS series, 3 labs; and Seric SXL-2500V2, 4 labs). Irradiation conditions could be optimized using quinine and sulisobenzone as positive and negative standards to offer consistent assay outcomes. In both solar simulators, the intra- and inter-day precisions (coefficient of variation; CV) for quinine were found to be below 10%. The inter-laboratory CV for quinine averaged 15.4% (Atlas Suntest CPS) and 13.2% (Seric SXL-2500V2) for singlet oxygen and 17.0% (Atlas Suntest CPS) and 7.1% (Seric SXL-2500V2) for superoxide, suggesting high inter-laboratory reproducibility even though different solar simulators were employed for the ROS assay. In the ROS assay on 42 coded chemicals, some chemicals (ca. 19-29%) were unevaluable because of limited solubility and spectral interference. Although several false positives appeared with positive predictivity of ca. 76-92% (Atlas Suntest CPS) and ca. 75-84% (Seric SXL-2500V2), there were no false negative predictions in both solar simulators. A multi-center validation study on the ROS assay demonstrated satisfactory transferability, accuracy, precision, and predictivity, as well as the availability of other solar simulators. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. International Laboratory Comparison of Influenza Microneutralization Assays for A(H1N1)pdm09, A(H3N2), and A(H5N1) Influenza Viruses by CONSISE

    PubMed Central

    Engelhardt, Othmar G.; Wood, John; Heath, Alan; Katz, Jacqueline M.; Peiris, Malik; Hoschler, Katja; Hungnes, Olav; Zhang, Wenqing; Van Kerkhove, Maria D.

    2015-01-01

    The microneutralization assay is commonly used to detect antibodies to influenza virus, and multiple protocols are used worldwide. These protocols differ in the incubation time of the assay as well as in the order of specific steps, and even within protocols there are often further adjustments in individual laboratories. The impact these protocol variations have on influenza serology data is unclear. Thus, a laboratory comparison of the 2-day enzyme-linked immunosorbent assay (ELISA) and 3-day hemagglutination (HA) microneutralization (MN) protocols, using A(H1N1)pdm09, A(H3N2), and A(H5N1) viruses, was performed by the CONSISE Laboratory Working Group. Individual laboratories performed both assay protocols, on multiple occasions, using different serum panels. Thirteen laboratories from around the world participated. Within each laboratory, serum sample titers for the different assay protocols were compared between assays to determine the sensitivity of each assay and were compared between replicates to assess the reproducibility of each protocol for each laboratory. There was good correlation of the results obtained using the two assay protocols in most laboratories, indicating that these assays may be interchangeable for detecting antibodies to the influenza A viruses included in this study. Importantly, participating laboratories have aligned their methodologies to the CONSISE consensus 2-day ELISA and 3-day HA MN assay protocols to enable better correlation of these assays in the future. PMID:26108286

  10. Rapid, Sensitive, Enzyme-Immunodotting Assay for Detecting Cow Milk Adulteration in Sheep Milk: A Modern Laboratory Project

    NASA Astrophysics Data System (ADS)

    Inda, Luis A.; Razquín, Pedro; Lampreave, Fermín; Alava, María A.; Calvo, Miguel

    1998-12-01

    Specificity, sensitivity, and experimental simplicity make the immunoenzymatic assay suitable for a variety of laboratories dedicated to diverse activities such as research, quality control in food analysis, or clinical biochemistry. In these assays, the antibody that specifically recognizes the antigen is covalently attached to an enzyme. Once the antigen-antibody immunocomplex is formed, the enzymatic reaction gives a colored product that allows the detection of the initial antigen. The aim of this work was the design of a new laboratory project appropriate for use in courses of biochemistry, immunochemistry, or analytical chemistry. The assay described here detects the presence of cow milk in milk of other species. The main application is the detection of cow milk in sheep milk and cheese. Specific proteins, immunoglobulins (IgG) of the fraudulent bovine milk, are specifically recognized and retained by antibodies immobilized on a membrane. The binding of a second antibody covalently attached to horseradish peroxidase (HRP) allows the development of a visible signal. Thus, students can rapidly detect milk adulterations using a specific, sensitive, and safe experimental approach. The experiment allows students to apply their theoretical knowledge, resulting in a stimulating experience of solving a real problem during a 4-hour laboratory period.

  11. Graphing techniques for materials laboratory using Excel

    NASA Technical Reports Server (NTRS)

    Kundu, Nikhil K.

    1994-01-01

    Engineering technology curricula stress hands on training and laboratory practices in most of the technical courses. Laboratory reports should include analytical as well as graphical evaluation of experimental data. Experience shows that many students neither have the mathematical background nor the expertise for graphing. This paper briefly describes the procedure and data obtained from a number of experiments such as spring rate, stress concentration, endurance limit, and column buckling for a variety of materials. Then with a brief introduction to Microsoft Excel the author explains the techniques used for linear regression and logarithmic graphing.

  12. Neutron assay in mixed radiation fields with a 6Li-loaded plastic scintillator

    NASA Astrophysics Data System (ADS)

    Balmer, M. J. I.; Gamage, K. A. A.; Taylor, G. C.

    2015-08-01

    A novel technique for assay of thermal and fast neutrons in a 6Li-loaded plastic scintillator is presented. Existing capture-gated thermal neutron detection techniques were evaluated with the 6Li-loaded plastic scintillator studied in this work. Using simulations and experimental work, shortcomings in its performance were highlighted. As a result, it was proposed that by separating the combined fast and thermal neutron events from gamma events, using established pulse shape discrimination techniques, the thermal neutron events could then be assayed. Experiments were conducted at the National Physical Laboratory, Teddington, performing neutron assays with seven different neutron fields using the proposed technique. For each field, thermal and fast neutron content was estimated and were shown to corroborate with the seven synthesised fields.

  13. Comparative evaluation of laboratory developed real-time PCR assays and RealStar(®) BKV PCR Kit for quantitative detection of BK polyomavirus.

    PubMed

    Hasan, Mohammad R; Tan, Rusung; Al-Rawahi, Ghada; Thomas, Eva; Tilley, Peter

    2016-08-01

    Quantitative, viral load monitoring for BK virus (BKV) by real-time PCR is an important tool in the management of polyomavirus associated nephropathy in renal transplant patients. However, variability in PCR results has been reported because of polymorphisms in viral genes among different subtypes of BKV, and lack of standardization of the PCR assays among different laboratories. In this study we have compared the performance of several laboratory developed PCR assays that target highly conserved regions of BKV genome with a commercially available, RealStar(®) BKV PCR Kit. Three real-time PCR assays (i) VP1 assay: selected from the literature that targets the major capsid protein (VP1) gene (ii) VP1MOD assay: VP1 assay with a modified probe, and (iii) BKLTA assay: newly designed assay that targets the large T antigen gene were assessed in parallel, using controls and clinical specimens that were previously tested using RealStar(®) BKV PCR Kit (Altona Diagnostics GmbH, Hamburg, Germany). Nucleic acid from all samples were extracted using the QIA symphony virus/bacteria kit on an automated DNA extraction platform QIA symphony SP (Qiagen). Primer and probe concentration, and reaction conditions for laboratory developed assays were optimized and the limit of detection of different assays was determined. Positive control for laboratory developed BK assays was prepared through construction of a plasmid carrying respective amplicon sequences. The 95% detection limit of VP1, VP1MOD and BKLTA assays were 1.8×10(2), 3×10(3) and 3.5×10(2) genomic copies/ml, respectively, as determined by Probit regression analysis of data obtained by testing a dilution series of a titered patient specimen, using RealStar(®) BKV PCR Kit. The inter-assay and intra-assay, coefficient of variations of these assays using calibrated, plasmid standards were <1%. All assays, including the RealStar(®) BKV PCR assay, were highly specific when tested against a panel of external proficiency

  14. Performance of human fecal anaerobe-associated PCR-based assays in a multi-laboratory method evaluation study

    USGS Publications Warehouse

    Layton, Blythe A.; Cao, Yiping; Ebentier, Darcy L.; Hanley, Kaitlyn; Ballesté, Elisenda; Brandão, João; Byappanahalli, Muruleedhara N.; Converse, Reagan; Farnleitner, Andreas H.; Gentry-Shields, Jennifer; Gourmelon, Michèle; Lee, Chang Soo; Lee, Jiyoung; Lozach, Solen; Madi, Tania; Meijer, Wim G.; Noble, Rachel; Peed, Lindsay; Reischer, Georg H.; Rodrigues, Raquel; Rose, Joan B.; Schriewer, Alexander; Sinigalliano, Chris; Srinivasan, Sangeetha; Stewart, Jill; ,; Laurie, C.; Wang, Dan; Whitman, Richard; Wuertz, Stefan; Jay, Jenny; Holden, Patricia A.; Boehm, Alexandria B.; Shanks, Orin; Griffith, John F.

    2013-01-01

    A number of PCR-based methods for detecting human fecal material in environmental waters have been developed over the past decade, but these methods have rarely received independent comparative testing in large multi-laboratory studies. Here, we evaluated ten of these methods (BacH, BacHum-UCD, Bacteroides thetaiotaomicron (BtH), BsteriF1, gyrB, HF183 endpoint, HF183 SYBR, HF183 Taqman®, HumM2, and Methanobrevibacter smithii nifH (Mnif)) using 64 blind samples prepared in one laboratory. The blind samples contained either one or two fecal sources from human, wastewater or non-human sources. The assay results were assessed for presence/absence of the human markers and also quantitatively while varying the following: 1) classification of samples that were detected but not quantifiable (DNQ) as positive or negative; 2) reference fecal sample concentration unit of measure (such as culturable indicator bacteria, wet mass, total DNA, etc); and 3) human fecal source type (stool, sewage or septage). Assay performance using presence/absence metrics was found to depend on the classification of DNQ samples. The assays that performed best quantitatively varied based on the fecal concentration unit of measure and laboratory protocol. All methods were consistently more sensitive to human stools compared to sewage or septage in both the presence/absence and quantitative analysis. Overall, HF183 Taqman® was found to be the most effective marker of human fecal contamination in this California-based study.

  15. Development and inter-laboratory validation study of an improved new real-time PCR assay with internal control for detection and laboratory diagnosis of African swine fever virus.

    PubMed

    Tignon, Marylène; Gallardo, Carmina; Iscaro, Carmen; Hutet, Evelyne; Van der Stede, Yves; Kolbasov, Denis; De Mia, Gian Mario; Le Potier, Marie-Frédérique; Bishop, Richard P; Arias, Marisa; Koenen, Frank

    2011-12-01

    A real-time polymerase chain reaction (PCR) assay for the rapid detection of African swine fever virus (ASFV), multiplexed for simultaneous detection of swine beta-actin as an endogenous control, has been developed and validated by four National Reference Laboratories of the European Union for African swine fever (ASF) including the European Union Reference Laboratory. Primers and a TaqMan(®) probe specific for ASFV were selected from conserved regions of the p72 gene. The limit of detection of the new real-time PCR assay is 5.7-57 copies of the ASFV genome. High accuracy, reproducibility and robustness of the PCR assay (CV ranging from 0.7 to 5.4%) were demonstrated both within and between laboratories using different real-time PCR equipments. The specificity of virus detection was validated using a panel of 44 isolates collected over many years in various geographical locations in Europe, Africa and America, including recent isolates from the Caucasus region, Sardinia, East and West Africa. Compared to the OIE-prescribed conventional and real-time PCR assays, the sensitivity of the new assay with internal control was improved, as demonstrated by testing 281 field samples collected in recent outbreaks and surveillance areas in Europe and Africa (170 samples) together with samples obtained through experimental infections (111 samples). This is particularly evident in the early days following experimental infection and during the course of the disease in pigs sub-clinically infected with strains of low virulence (from 35 up to 70dpi). The specificity of the assay was also confirmed on 150 samples from uninfected pigs and wild boar from ASF-free areas. Measured on the total of 431 tested samples, the positive deviation of the new assay reaches 21% or 26% compared to PCR and real-time PCR methods recommended by OIE. This improved and rigorously validated real-time PCR assay with internal control will provide a rapid, sensitive and reliable molecular tool for ASFV

  16. MATERIALS AND TECHNIQUES FOR THE LANGUAGE LABORATORY.

    ERIC Educational Resources Information Center

    NAJAM, EDWARD W.

    THE PROCEEDINGS OF THE SECOND ANNUAL INDIANA-PURDUE LANGUAGE LABORATORY CONFERENCE ARE ORGANIZED, AFTER INTRODUCTORY STATEMENTS BY NAJAM AND LARSEN ON CONTEMPORARY TRENDS IN LANGUAGE INSTRUCTION, UNDER THREE GENERAL HEADINGS PLUS APPENDIXES. IN THE FIRST SECTION DEVOTED TO MATERIALS AND TECHNIQUES ARE ARTICLES BY HYER, GARIMALDI, EDDY, AND SMITH…

  17. Analysis of Citric Acid in Beverages: Use of an Indicator Displacement Assay

    ERIC Educational Resources Information Center

    Umali, Alona P.; Anslyn, Eric V.; Wright, Aaron T.; Blieden, Clifford R.; Smith, Carolyne K.; Tian, Tian; Truong, Jennifer A.; Crumm, Caitlin E.; Garcia, Jorge E.; Lee, Soal; Mosier, Meredith; Nguyen, Chester P.

    2010-01-01

    The use of an indicator displacement assay permits the visualization of binding events between host and guest molecules. An undergraduate laboratory experiment is described to demonstrate the technique in the determination of citric acid content in commercially available beverages such as soda pop and fruit juices. Through the technique, students…

  18. Protein immobilization techniques for microfluidic assays

    PubMed Central

    Kim, Dohyun; Herr, Amy E.

    2013-01-01

    Microfluidic systems have shown unequivocal performance improvements over conventional bench-top assays across a range of performance metrics. For example, specific advances have been made in reagent consumption, throughput, integration of multiple assay steps, assay automation, and multiplexing capability. For heterogeneous systems, controlled immobilization of reactants is essential for reliable, sensitive detection of analytes. In most cases, protein immobilization densities are maximized, while native activity and conformation are maintained. Immobilization methods and chemistries vary significantly depending on immobilization surface, protein properties, and specific assay goals. In this review, we present trade-offs considerations for common immobilization surface materials. We overview immobilization methods and chemistries, and discuss studies exemplar of key approaches—here with a specific emphasis on immunoassays and enzymatic reactors. Recent “smart immobilization” methods including the use of light, electrochemical, thermal, and chemical stimuli to attach and detach proteins on demand with precise spatial control are highlighted. Spatially encoded protein immobilization using DNA hybridization for multiplexed assays and reversible protein immobilization surfaces for repeatable assay are introduced as immobilization methods. We also describe multifunctional surface coatings that can perform tasks that were, until recently, relegated to multiple functional coatings. We consider the microfluidics literature from 1997 to present and close with a perspective on future approaches to protein immobilization. PMID:24003344

  19. Gamma neutron assay method and apparatus

    DOEpatents

    Cole, J.D.; Aryaeinejad, R.; Greenwood, R.C.

    1995-01-03

    The gamma neutron assay technique is an alternative method to standard safeguards techniques for the identification and assaying of special nuclear materials in a field or laboratory environment, as a tool for dismantlement and destruction of nuclear weapons, and to determine the isotopic ratios for a blend-down program on uranium. It is capable of determining the isotopic ratios of fissionable material from the spontaneous or induced fission of a sample to within approximately 0.5%. This is based upon the prompt coincidence relationships that occur in the fission process and the proton conservation and quasi-conservation of nuclear mass (A) that exists between the two fission fragments. The system is used in both passive (without an external neutron source) and active (with an external neutron source) mode. The apparatus consists of an array of neutron and gamma-ray detectors electronically connected to determine coincident events. The method can also be used to assay radioactive waste which contains fissile material, even in the presence of a high background radiation field. 7 figures.

  20. Gamma neutron assay method and apparatus

    DOEpatents

    Cole, Jerald D.; Aryaeinejad, Rahmat; Greenwood, Reginald C.

    1995-01-01

    The gamma neutron assay technique is an alternative method to standard safeguards techniques for the identification and assaying of special nuclear materials in a field or laboratory environment, as a tool for dismantlement and destruction of nuclear weapons, and to determine the isotopic ratios for a blend-down program on uranium. It is capable of determining the isotopic ratios of fissionable material from the spontaneous or induced fission of a sample to within approximately 0.5%. This is based upon the prompt coincidence relationships that occur in the fission process and the proton conservation and quasi-conservation of nuclear mass (A) that exists between the two fission fragments. The system is used in both passive (without an external neutron source and active (with an external neutron source) mode. The apparatus consists of an array of neutron and gamma-ray detectors electronically connected to determine coincident events. The method can also be used to assay radioactive waste which contains fissile material, even in the presence of a high background radiation field.

  1. Equivalence of ELISpot Assays Demonstrated between Major HIV Network Laboratories

    PubMed Central

    Levine, Gail L.; Sambor, Anna; Carter, Donald K.; Sato, Alicia; Kopycinski, Jakub; Hayes, Peter; Hahn, Bridget; Birungi, Josephine; Tarragona-Fiol, Tony; Wan, Hong; Randles, Mark; Cooper, Andrew Raxworthy; Ssemaganda, Aloysius; Clark, Lorna; Kaleebu, Pontiano; Self, Steven G.; Koup, Richard; Wood, Blake; McElrath, M. Juliana; Cox, Josephine H.; Hural, John; Gilmour, Jill

    2010-01-01

    Background The Comprehensive T Cell Vaccine Immune Monitoring Consortium (CTC-VIMC) was created to provide standardized immunogenicity monitoring services for HIV vaccine trials. The ex vivo interferon-gamma (IFN-γ) ELISpot is used extensively as a primary immunogenicity assay to assess T cell-based vaccine candidates in trials for infectious diseases and cancer. Two independent, GCLP-accredited central laboratories of CTC-VIMC routinely use their own standard operating procedures (SOPs) for ELISpot within two major networks of HIV vaccine trials. Studies are imperatively needed to assess the comparability of ELISpot measurements across laboratories to benefit optimal advancement of vaccine candidates. Methods We describe an equivalence study of the two independently qualified IFN-g ELISpot SOPs. The study design, data collection and subsequent analysis were managed by independent statisticians to avoid subjectivity. The equivalence of both response rates and positivity calls to a given stimulus was assessed based on pre-specified acceptance criteria derived from a separate pilot study. Findings Detection of positive responses was found to be equivalent between both laboratories. The 95% C.I. on the difference in response rates, for CMV (−1.5%, 1.5%) and CEF (−0.4%, 7.8%) responses, were both contained in the pre-specified equivalence margin of interval [−15%, 15%]. The lower bound of the 95% C.I. on the proportion of concordant positivity calls for CMV (97.2%) and CEF (89.5%) were both greater than the pre-specified margin of 70%. A third CTC-VIMC central laboratory already using one of the two SOPs also showed comparability when tested in a smaller sub-study. Interpretation The described study procedure provides a prototypical example for the comparison of bioanalytical methods in HIV vaccine and other disease fields. This study also provides valuable and unprecedented information for future vaccine candidate evaluations on the comparison and pooling of

  2. Development of a multiplex serological assay reveals a worldwide distribution of murine astrovirus infections in laboratory mice.

    PubMed

    Schmidt, Katja; Butt, Julia; Mauter, Petra; Vogel, Klaus; Erles-Kemna, Andrea; Pawlita, Michael; Nicklas, Werner

    2017-01-01

    Laboratory mice play a tremendous role in biomedical research in studies on immunology, infection, cancer and therapy. In the course of standardization of mice used in animal experiments, health monitoring constitutes an important instrument towards microbiological standardization. Infections with murine astroviruses (MuAstV) were only recently discovered and are, therefore, still relatively unknown in laboratory animal science. In rodent health monitoring viral infections within a population are commonly assessed in terms of specific antibodies by serological testing, as active infection and excretion of virus is often temporary and can easily be missed. So far only ongoing infections with astroviruses can be detected by PCR. The objective of this work was the development of a sensitive and specific MuAstV multiplex serological assay with a high-throughput capability to be used in routine testing of laboratory mice. Four different MuAstV proteins were recombinantly expressed and used as antigens. The best reacting antigen, the capsid spike protein VP27, was selected and tested with a panel of 400 sera of mice from units with a known MuAstV status. Assay sensitivity and specificity resulted in 98.5% and 100%, respectively, compared to RT-PCR results. Eventually this assay was used to test 5529 serum samples in total, during routine diagnostics at the German Cancer Research Center (DKFZ) in Heidelberg between 2015 and 2017. High sero-prevalence rates of up to 98% were detected in units with open cages indicating that the virus is highly infectious and circulates within these populations virtually infecting all animals regardless of the mouse strain. In addition, data collected from 312 mice purchased from commercial breeders and from 661 mice from 58 research institutes in 15 countries worldwide allowed the conclusion that MuAstV is widespread in contemporary laboratory mouse populations.

  3. Performance of the TB-LAMP diagnostic assay in reference laboratories: Results from a multicentre study.

    PubMed

    Pham, Thu Hang; Peter, Jonathan; Mello, Fernanda C Q; Parraga, Tommy; Lan, Nguyen Thi Ngoc; Nabeta, Pamela; Valli, Eloise; Caceres, Tatiana; Dheda, Keertan; Dorman, Susan E; Hillemann, Doris; Gray, Christen M; Perkins, Mark D

    2018-03-01

    To evaluate the diagnostic performance of TB-LAMP, a manual molecular tuberculosis (TB) detection method, and provide comparison to the Xpert MTB/RIF assay. In a large multicentre study, two sputum samples were collected from participants with TB symptoms in reference laboratories in Peru, South Africa, Brazil, and Vietnam. Each sample was tested with TB-LAMP. The reference standard consisted of four direct smears, four cultures, and clinical and radiological findings. Individuals negative on conventional tests were followed up after 8 weeks. The Xpert MTB/RIF assay was performed on fresh or frozen samples as a molecular test comparison. A total of 1036 adults with suspected TB were enrolled. Among 375 culture-confirmed TB cases with 750 sputum samples, TB-LAMP detected 75.6% (95% confidence interval (CI) 71.8-79.4%), including 97.9% (95% CI 96.4-99.4%) of smear-positive TB samples and 46.6% (95% CI 40.6-52.7%) of smear-negative TB samples. Specificity in 477 culture-negative participants not treated for TB (954 sputum samples) was 98.7% (95% CI 97.9-99.6%). TB-LAMP test results were indeterminate in 0.3% of cases. TB-LAMP detects nearly all smear-positive and half of smear-negative TB cases and has a high specificity when performed in reference laboratories. Performance was similar to the Xpert MTB/RIF assay. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  4. Use of diagnostic accuracy as a metric for evaluating laboratory proficiency with microarray assays using mixed-tissue RNA reference samples.

    PubMed

    Pine, P S; Boedigheimer, M; Rosenzweig, B A; Turpaz, Y; He, Y D; Delenstarr, G; Ganter, B; Jarnagin, K; Jones, W D; Reid, L H; Thompson, K L

    2008-11-01

    Effective use of microarray technology in clinical and regulatory settings is contingent on the adoption of standard methods for assessing performance. The MicroArray Quality Control project evaluated the repeatability and comparability of microarray data on the major commercial platforms and laid the groundwork for the application of microarray technology to regulatory assessments. However, methods for assessing performance that are commonly applied to diagnostic assays used in laboratory medicine remain to be developed for microarray assays. A reference system for microarray performance evaluation and process improvement was developed that includes reference samples, metrics and reference datasets. The reference material is composed of two mixes of four different rat tissue RNAs that allow defined target ratios to be assayed using a set of tissue-selective analytes that are distributed along the dynamic range of measurement. The diagnostic accuracy of detected changes in expression ratios, measured as the area under the curve from receiver operating characteristic plots, provides a single commutable value for comparing assay specificity and sensitivity. The utility of this system for assessing overall performance was evaluated for relevant applications like multi-laboratory proficiency testing programs and single-laboratory process drift monitoring. The diagnostic accuracy of detection of a 1.5-fold change in signal level was found to be a sensitive metric for comparing overall performance. This test approaches the technical limit for reliable discrimination of differences between two samples using this technology. We describe a reference system that provides a mechanism for internal and external assessment of laboratory proficiency with microarray technology and is translatable to performance assessments on other whole-genome expression arrays used for basic and clinical research.

  5. Performance evaluation of new automated hepatitis B viral markers in the clinical laboratory: two quantitative hepatitis B surface antigen assays and an HBV core-related antigen assay.

    PubMed

    Park, Yongjung; Hong, Duck Jin; Shin, Saeam; Cho, Yonggeun; Kim, Hyon-Suk

    2012-05-01

    We evaluated quantitative hepatitis B surface antigen (qHBsAg) assays and a hepatitis B virus (HBV) core-related antigen (HBcrAg) assay. A total of 529 serum samples from patients with hepatitis B were tested. HBsAg levels were determined by using the Elecsys (Roche Diagnostics, Indianapolis, IN) and Architect (Abbott Laboratories, Abbott Park, IL) qHBsAg assays. HBcrAg was measured by using Lumipulse HBcrAg assay (Fujirebio, Tokyo, Japan). Serum aminotransferases and HBV DNA were respectively quantified by using the Hitachi 7600 analyzer (Hitachi High-Technologies, Tokyo, Japan) and the Cobas AmpliPrep/Cobas TaqMan test (Roche). Precision of the qHBsAg and HBcrAg assays was assessed, and linearity of the qHBsAg assays was verified. All assays showed good precision performance with coefficients of variation between 4.5% and 5.3% except for some levels. Both qHBsAg assays showed linearity from 0.1 to 12,000.0 IU/mL and correlated well (r = 0.9934). HBsAg levels correlated with HBV DNA (r = 0.3373) and with HBcrAg (r = 0.5164), and HBcrAg also correlated with HBV DNA (r = 0.5198; P < .0001). This observation could provide impetus for further research to elucidate the clinical usefulness of the qHBsAg and HBcrAg assays.

  6. Using ATP-driven bioluminescence assay to monitor microbial safety in a contemporary human cadaver laboratory.

    PubMed

    Benninger, Brion; Maier, Thomas

    2015-03-01

    The objective of this study was to utilize a cost-effective method for assessing the levels of bacterial, yeast, and mold activity during a human dissection laboratory course. Nowadays, compliance with safety regulations is policed by institutions at higher standards than ever before. Fear of acquiring an unknown infection is one of the top concerns of professional healthcare students, and it provokes anti-laboratory anxiety. Human cadavers are not routinely tested for bacteria and viruses prior to embalming. Human anatomy dissecting rooms that house embalmed cadavers are normally cleaned after the dissected cadavers have been removed. There is no evidence that investigators have ever assessed bacterial and fungal activities using adenosine triphosphate (ATP)-driven bioluminescence assays. A literature search was conducted on texts, journals, and websites regarding bacterial, yeast, and mold activities in an active cadaver laboratory. Midway into a clinical anatomy course, ATP bioluminescence assays were used to swab various sites within the dissection room, including entrance and exiting door handles, water taps, cadaver tables, counter tops, imaging material, X-ray box switches, and the cadaver surfaces. The results demonstrated very low activities on cadaver tables, washing up areas, and exiting door handles. There was low activity on counter tops and X-ray boxes. There was medium activity on the entrance door handles. These findings suggest an inexpensive and accurate method for monitoring safety compliance and microbial activity. Students can feel confident and safe in the environment in which they work. © 2014 Wiley Periodicals, Inc.

  7. Virtual lab demonstrations improve students' mastery of basic biology laboratory techniques.

    PubMed

    Maldarelli, Grace A; Hartmann, Erica M; Cummings, Patrick J; Horner, Robert D; Obom, Kristina M; Shingles, Richard; Pearlman, Rebecca S

    2009-01-01

    Biology laboratory classes are designed to teach concepts and techniques through experiential learning. Students who have never performed a technique must be guided through the process, which is often difficult to standardize across multiple lab sections. Visual demonstration of laboratory procedures is a key element in teaching pedagogy. The main goals of the study were to create videos explaining and demonstrating a variety of lab techniques that would serve as teaching tools for undergraduate and graduate lab courses and to assess the impact of these videos on student learning. Demonstrations of individual laboratory procedures were videotaped and then edited with iMovie. Narration for the videos was edited with Audacity. Undergraduate students were surveyed anonymously prior to and following screening to assess the impact of the videos on student lab performance by completion of two Participant Perception Indicator surveys. A total of 203 and 171 students completed the pre- and posttesting surveys, respectively. Statistical analyses were performed to compare student perceptions of knowledge of, confidence in, and experience with the lab techniques before and after viewing the videos. Eleven demonstrations were recorded. Chi-square analysis revealed a significant increase in the number of students reporting increased knowledge of, confidence in, and experience with the lab techniques after viewing the videos. Incorporation of instructional videos as prelaboratory exercises has the potential to standardize techniques and to promote successful experimental outcomes.

  8. Relative sensitivity of conventional and real-time PCR assays for detection of SFG Rickettsia in blood and tissue samples from laboratory animals.

    PubMed

    Zemtsova, Galina E; Montgomery, Merrill; Levin, Michael L

    2015-01-01

    Studies on the natural transmission cycles of zoonotic pathogens and the reservoir competence of vertebrate hosts require methods for reliable diagnosis of infection in wild and laboratory animals. Several PCR-based applications have been developed for detection of infections caused by Spotted Fever group Rickettsia spp. in a variety of animal tissues. These assays are being widely used by researchers, but they differ in their sensitivity and reliability. We compared the sensitivity of five previously published conventional PCR assays and one SYBR green-based real-time PCR assay for the detection of rickettsial DNA in blood and tissue samples from Rickettsia- infected laboratory animals (n = 87). The real-time PCR, which detected rickettsial DNA in 37.9% of samples, was the most sensitive. The next best were the semi-nested ompA assay and rpoB conventional PCR, which detected as positive 18.4% and 14.9% samples respectively. Conventional assays targeting ompB, gltA and hrtA genes have been the least sensitive. Therefore, we recommend the SYBR green-based real-time PCR as a tool for the detection of rickettsial DNA in animal samples due to its higher sensitivity when compared to more traditional assays.

  9. Aseptic laboratory techniques: plating methods.

    PubMed

    Sanders, Erin R

    2012-05-11

    Microorganisms are present on all inanimate surfaces creating ubiquitous sources of possible contamination in the laboratory. Experimental success relies on the ability of a scientist to sterilize work surfaces and equipment as well as prevent contact of sterile instruments and solutions with non-sterile surfaces. Here we present the steps for several plating methods routinely used in the laboratory to isolate, propagate, or enumerate microorganisms such as bacteria and phage. All five methods incorporate aseptic technique, or procedures that maintain the sterility of experimental materials. Procedures described include (1) streak-plating bacterial cultures to isolate single colonies, (2) pour-plating and (3) spread-plating to enumerate viable bacterial colonies, (4) soft agar overlays to isolate phage and enumerate plaques, and (5) replica-plating to transfer cells from one plate to another in an identical spatial pattern. These procedures can be performed at the laboratory bench, provided they involve non-pathogenic strains of microorganisms (Biosafety Level 1, BSL-1). If working with BSL-2 organisms, then these manipulations must take place in a biosafety cabinet. Consult the most current edition of the Biosafety in Microbiological and Biomedical Laboratories (BMBL) as well as Material Safety Data Sheets (MSDS) for Infectious Substances to determine the biohazard classification as well as the safety precautions and containment facilities required for the microorganism in question. Bacterial strains and phage stocks can be obtained from research investigators, companies, and collections maintained by particular organizations such as the American Type Culture Collection (ATCC). It is recommended that non-pathogenic strains be used when learning the various plating methods. By following the procedures described in this protocol, students should be able to: Perform plating procedures without contaminating media. Isolate single bacterial colonies by the streak

  10. Aseptic Laboratory Techniques: Plating Methods

    PubMed Central

    Sanders, Erin R.

    2012-01-01

    Microorganisms are present on all inanimate surfaces creating ubiquitous sources of possible contamination in the laboratory. Experimental success relies on the ability of a scientist to sterilize work surfaces and equipment as well as prevent contact of sterile instruments and solutions with non-sterile surfaces. Here we present the steps for several plating methods routinely used in the laboratory to isolate, propagate, or enumerate microorganisms such as bacteria and phage. All five methods incorporate aseptic technique, or procedures that maintain the sterility of experimental materials. Procedures described include (1) streak-plating bacterial cultures to isolate single colonies, (2) pour-plating and (3) spread-plating to enumerate viable bacterial colonies, (4) soft agar overlays to isolate phage and enumerate plaques, and (5) replica-plating to transfer cells from one plate to another in an identical spatial pattern. These procedures can be performed at the laboratory bench, provided they involve non-pathogenic strains of microorganisms (Biosafety Level 1, BSL-1). If working with BSL-2 organisms, then these manipulations must take place in a biosafety cabinet. Consult the most current edition of the Biosafety in Microbiological and Biomedical Laboratories (BMBL) as well as Material Safety Data Sheets (MSDS) for Infectious Substances to determine the biohazard classification as well as the safety precautions and containment facilities required for the microorganism in question. Bacterial strains and phage stocks can be obtained from research investigators, companies, and collections maintained by particular organizations such as the American Type Culture Collection (ATCC). It is recommended that non-pathogenic strains be used when learning the various plating methods. By following the procedures described in this protocol, students should be able to: ● Perform plating procedures without contaminating media. ● Isolate single bacterial colonies by the

  11. CPTAC Assay Portal: a repository of targeted proteomic assays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whiteaker, Jeffrey R.; Halusa, Goran; Hoofnagle, Andrew N.

    2014-06-27

    To address these issues, the Clinical Proteomic Tumor Analysis Consortium (CPTAC) of the National Cancer Institute (NCI) has launched an Assay Portal (http://assays.cancer.gov) to serve as a public repository of well-characterized quantitative, MS-based, targeted proteomic assays. The purpose of the CPTAC Assay Portal is to facilitate widespread adoption of targeted MS assays by disseminating SOPs, reagents, and assay characterization data for highly characterized assays. A primary aim of the NCI-supported portal is to bring together clinicians or biologists and analytical chemists to answer hypothesis-driven questions using targeted, MS-based assays. Assay content is easily accessed through queries and filters, enabling investigatorsmore » to find assays to proteins relevant to their areas of interest. Detailed characterization data are available for each assay, enabling researchers to evaluate assay performance prior to launching the assay in their own laboratory.« less

  12. Adapting High-Throughput Screening Methods and Assays for Biocontainment Laboratories

    PubMed Central

    Tigabu, Bersabeh; White, E. Lucile; Bostwick, Robert; Tower, Nichole; Bukreyev, Alexander; Rockx, Barry; LeDuc, James W.; Noah, James W.

    2015-01-01

    Abstract High-throughput screening (HTS) has been integrated into the drug discovery process, and multiple assay formats have been widely used in many different disease areas but with limited focus on infectious agents. In recent years, there has been an increase in the number of HTS campaigns using infectious wild-type pathogens rather than surrogates or biochemical pathogen-derived targets. Concurrently, enhanced emerging pathogen surveillance and increased human mobility have resulted in an increase in the emergence and dissemination of infectious human pathogens with serious public health, economic, and social implications at global levels. Adapting the HTS drug discovery process to biocontainment laboratories to develop new drugs for these previously uncharacterized and highly pathogenic agents is now feasible, but HTS at higher biosafety levels (BSL) presents a number of unique challenges. HTS has been conducted with multiple bacterial and viral pathogens at both BSL-2 and BSL-3, and pilot screens have recently been extended to BSL-4 environments for both Nipah and Ebola viruses. These recent successful efforts demonstrate that HTS can be safely conducted at the highest levels of biological containment. This review outlines the specific issues that must be considered in the execution of an HTS drug discovery program for high-containment pathogens. We present an overview of the requirements for HTS in high-level biocontainment laboratories. PMID:25710545

  13. Measuring Norfloxacin Binding to Trypsin Using a Fluorescence Quenching Assay in an Upper-Division, Integrated Laboratory Course

    ERIC Educational Resources Information Center

    Hicks, Katherine A.

    2016-01-01

    Fluorescence quenching assays are often used to measure dissociation constants that quantify the binding affinity between small molecules and proteins. In an upper-division undergraduate laboratory course, where students work on projects using a guided inquiry-based approach, a binding titration experiment at physiological pH is performed to…

  14. The Acetylene-Ethylene Assay for N2 Fixation: Laboratory and Field Evaluation 1

    PubMed Central

    Hardy, R. W. F.; Holsten, R. D.; Jackson, E. K.; Burns, R. C.

    1968-01-01

    The methodology, characteristics and application of the sensitive C2H2-C2H4 assay for N2 fixation by nitrogenase preparations and bacterial cultures in the laboratory and by legumes and free-living bacteria in situ is presented in this comprehensive report. This assay is based on the N2ase-catalyzed reduction of C2H2 to C2H4, gas chromatographic isolation of C2H2 and C2H4, and quantitative measurement with a H2-flame analyzer. As little as 1 μμmole C2H4 can be detected, providing a sensitivity 103-fold greater than is possible with 15N analysis. A simple, rapid and effective procedure utilizing syringe-type assay chambers is described for the analysis of C2H2-reducing activity in the field. Applications to field samples included an evaluation of N2 fixation by commercially grown soybeans based on over 2000 analyses made during the course of the growing season. Assay values reflected the degree of nodulation of soybean plants and indicated a calculated seasonal N2 fixation rate of 30 to 33 kg N2 fixed per acre, in good agreement with literature estimates based on Kjeldahl analyses. The assay was successfully applied to measurements of N2 fixation by other symbionts and by free living soil microorganisms, and was also used to assess the effects of light and temperature on the N2 fixing activity of soybeans. The validity of measuring N2 fixation in terms of C2H2 reduction was established through extensive comparisons of these activities using defined systems, including purified N2ase preparations and pure cultures of N2-fixing bacteria. With this assay it now becomes possible and practicable to conduct comprehensive surveys of N2 fixation, to make detailed comparisons among different N2-fixing symbionts, and to rapidly evaluate the effects of cultural practices and environmental factors on N2 fixation. The knowledge obtained through extensive application of this assay should provide the basis for efforts leading to the maximum agricultural exploitation of the N2

  15. NCL-01: Nanomedicine Drug Release Study in Human Plasma Using Stable Isotope Tracer Ultrafiltration Assay (SITUA)  | Frederick National Laboratory for Cancer Research

    Cancer.gov

    The Nanotechnology Characterization Laboratory will evaluate drug release from a nanoparticulate formulation in vitro in human plasma, using a novel stable isotope tracer ultrafiltration assay (SITUA) developed at the laboratory. The SITUA is a metho

  16. Performance of PCR-based and Bioluminescent assays for mycoplasma detection.

    PubMed

    Falagan-Lotsch, Priscila; Lopes, Talíria Silva; Ferreira, Nívea; Balthazar, Nathália; Monteiro, Antônio M; Borojevic, Radovan; Granjeiro, José Mauro

    2015-11-01

    Contaminated eukaryotic cell cultures are frequently responsible for unreliable results. Regulatory entities request that cell cultures must be mycoplasma-free. Mycoplasma contamination remains a significant problem for cell cultures and may have an impact on biological analysis since they affect many cell parameters. The gold standard microbiological assay for mycoplasma detection involves laborious and time-consuming protocols. PCR-based and Bioluminescent assays have been considered for routine cell culture screening in research laboratories since they are fast, easy and sensitive. Thus, the aim of this work is to compare the performance of two popular commercial assays, PCR-based and Bioluminescent assays, by assessing the level of mycoplasma contamination in cell cultures from Rio de Janeiro Cell Bank (RJCB) and also from customers' laboratories. The results obtained by both performed assays were confirmed by scanning electron microscopy. In addition, we evaluated the limit of detection of the PCR kit under our laboratory conditions and the storage effects on mycoplasma detection in frozen cell culture supernatants. The performance of both assays for mycoplasma detection was not significantly different and they showed very good agreement. The Bioluminescent assay for mycoplasma detection was slightly more dependable than PCR-based due to the lack of inconclusive results produced by the first technique, especially considering the ability to detect mycoplasma contamination in frozen cell culture supernatants. However, cell lines should be precultured for four days or more without antibiotics to obtain safe results. On the other hand, a false negative result was obtained by using this biochemical approach. The implementation of fast and reliable mycoplasma testing methods is an important technical and regulatory issue and PCR-based and Bioluminescent assays may be good candidates. However, validation studies are needed. Copyright © 2015 Elsevier B.V. All rights

  17. Relative Sensitivity of Conventional and Real-Time PCR Assays for Detection of SFG Rickettsia in Blood and Tissue Samples from Laboratory Animals

    PubMed Central

    Zemtsova, Galina E.; Montgomery, Merrill; Levin, Michael L.

    2015-01-01

    Studies on the natural transmission cycles of zoonotic pathogens and the reservoir competence of vertebrate hosts require methods for reliable diagnosis of infection in wild and laboratory animals. Several PCR-based applications have been developed for detection of infections caused by Spotted Fever group Rickettsia spp. in a variety of animal tissues. These assays are being widely used by researchers, but they differ in their sensitivity and reliability. We compared the sensitivity of five previously published conventional PCR assays and one SYBR green-based real-time PCR assay for the detection of rickettsial DNA in blood and tissue samples from Rickettsia- infected laboratory animals (n = 87). The real-time PCR, which detected rickettsial DNA in 37.9% of samples, was the most sensitive. The next best were the semi-nested ompA assay and rpoB conventional PCR, which detected as positive 18.4% and 14.9% samples respectively. Conventional assays targeting ompB, gltA and hrtA genes have been the least sensitive. Therefore, we recommend the SYBR green-based real-time PCR as a tool for the detection of rickettsial DNA in animal samples due to its higher sensitivity when compared to more traditional assays. PMID:25607846

  18. A laboratory-scale pretreatment and hydrolysis assay for determination of reactivity in cellulosic biomass feedstocks.

    PubMed

    Wolfrum, Edward J; Ness, Ryan M; Nagle, Nicholas J; Peterson, Darren J; Scarlata, Christopher J

    2013-11-14

    The rapid determination of the release of structural sugars from biomass feedstocks is an important enabling technology for the development of cellulosic biofuels. An assay that is used to determine sugar release for large numbers of samples must be robust, rapid, and easy to perform, and must use modest amounts of the samples to be tested.In this work we present a laboratory-scale combined pretreatment and saccharification assay that can be used as a biomass feedstock screening tool. The assay uses a commercially available automated solvent extraction system for pretreatment followed by a small-scale enzymatic hydrolysis step. The assay allows multiple samples to be screened simultaneously, and uses only ~3 g of biomass per sample. If the composition of the biomass sample is known, the results of the assay can be expressed as reactivity (fraction of structural carbohydrate present in the biomass sample released as monomeric sugars). We first present pretreatment and enzymatic hydrolysis experiments on a set of representative biomass feedstock samples (corn stover, poplar, sorghum, switchgrass) in order to put the assay in context, and then show the results of the assay applied to approximately 150 different feedstock samples covering 5 different materials. From the compositional analysis data we identify a positive correlation between lignin and structural carbohydrates, and from the reactivity data we identify a negative correlation between both carbohydrate and lignin content and total reactivity. The negative correlation between lignin content and total reactivity suggests that lignin may interfere with sugar release, or that more mature samples (with higher structural sugars) may have more recalcitrant lignin. The assay presented in this work provides a robust and straightforward method to measure the sugar release after pretreatment and saccharification that can be used as a biomass feedstock screening tool. We demonstrated the utility of the assay by

  19. Influenza surveillance: alternative laboratory techniques for a developing country*

    PubMed Central

    Canil, K. A.; Pratt, D.; Sungu, M. S.; Phillips, P. A.

    1985-01-01

    In developing countries it is often impractical to use conventional methods to isolate and identify influenza viruses. The use of trypsin-treated LLC-MK2 cells for the isolation of myxoviruses, in conjunction with the indirect fluorescent antibody technique for identification of isolates and for direct detection of viral antigens in specimens, was an effective combination of techniques which enabled our laboratory in Papua New Guinea to participate in an influenza surveillance programme. The application of these techniques in routine respiratory virus surveillance and in the investigation of an outbreak of influenza-like illness is described. PMID:3872737

  20. Long-Term Performance of Point-of-Care Hemoglobin A1c Assays

    PubMed Central

    Paknikar, Sujaytha; Sarmah, Rohan; Sivaganeshan, Losika; Welke, Adam; Rizzo, Al; Larson, Kirk; Rendell, Marc

    2016-01-01

    Background: Point-of-care (POC) testing of HbA1c is used as a time-efficient tool to improve treatment and management planning for diabetes in the clinic setting. HbA1c values are the basis for monitoring ongoing response to treatment and to make adjustments to diabetes therapy. Yet, there is ongoing controversy as to the accuracy of POC assays. Diabetes is a lifelong disease, so comparability of results over a long period of time is needed to follow the response to treatment. Methods: We compared the Afinion™ automated boronate affinity assay and the DCA Vantage immunoassay-based POC techniques to the Tosoh G8 and Bio-Rad Variant II ion-exchange high-performance liquid chromatography (HPLC) central laboratory methods in a study lasting 3 years. College of American Pathology Survey results and American Proficiency testing were utilized to assess the external validity of the POC techniques. Results: Despite high correlations among the 4 techniques, there were significant and variable differences obtained over time. The Biorad values varied from 0.1 to 0.4% higher than the Afinion values. The DCA results were usually higher than the Afinion values, but fell below the Afinion results in the last 6 months of our study. Both POC techniques gave systematically lower values than the Tosoh measurements, and both the POC and the central laboratory measurements showed variable differences from the National Glycohemoglobin Standardization Program values over the duration of this study. Conclusions: All who rely on POC methods as well as on central laboratory measurement of HbA1c must understand the potential limitations of these assays. The assessment of diabetes blood sugar control should proceed from the evaluation of HbA1c combined with review of plasma glucose and of self-monitored blood glucose values. PMID:27113451

  1. Steroid Assays in Paediatric Endocrinology

    PubMed Central

    2010-01-01

    Most steroid disorders of the adrenal cortex come to clinical attention in childhood and in order to investigate these problems, there are many challenges to the laboratory which need to be appreciated to a certain extent by clinicians. The analysis of sex steroids in biological fluids from neonates, over adrenarche and puberty present challenges of specificities and concentrations often in small sample sizes. Different reference ranges are also needed for interpretations. For around 40 years, quantitative assays for the steroids and their regulatory peptide hormones have been possible using immunoassay techniques. Problems are recognised and this review aims to summarise the benefits and failings of immunoassays and introduce where tandem mass spectrometry is anticipated to meet the clinical needs for steroid analysis in paediatric endocrine investigations. It is important to keep a dialogue between clinicians and the laboratory, especially when any laboratory result does not make sense in the clinical investigation. Conflict of interest:None declared. PMID:21274330

  2. A comparison of high-throughput techniques for assaying circadian rhythms in plants.

    PubMed

    Tindall, Andrew J; Waller, Jade; Greenwood, Mark; Gould, Peter D; Hartwell, James; Hall, Anthony

    2015-01-01

    Over the last two decades, the development of high-throughput techniques has enabled us to probe the plant circadian clock, a key coordinator of vital biological processes, in ways previously impossible. With the circadian clock increasingly implicated in key fitness and signalling pathways, this has opened up new avenues for understanding plant development and signalling. Our tool-kit has been constantly improving through continual development and novel techniques that increase throughput, reduce costs and allow higher resolution on the cellular and subcellular levels. With circadian assays becoming more accessible and relevant than ever to researchers, in this paper we offer a review of the techniques currently available before considering the horizons in circadian investigation at ever higher throughputs and resolutions.

  3. Transitioning cytomegalovirus viral load testing from a laboratory developed test to the cobas® CMV quantitative nucleic acid assay.

    PubMed

    Payne, Michael; Merrick, Linda; Lawson, Tanya; Ritchie, Gordon; Lowe, Christopher

    2018-04-16

    Commutability between human cytomegalovirus (CMV) viral load assays (VLA) is poor, despite the development of a WHO CMV International Standard (CMV IS). We evaluated a new CMV VLA, cobas ® CMV, as compared to our current laboratory developed CMV VLA (LDT), for clinical use. Both the LDT and cobas ® CMV were run in parallel for 109 patient samples. In addition, 104 replicates, over 8 dilutions, of the CMV IS were tested. Conversion factors and correlation between the two assays were calculated. The correlation coefficient between the LDT and cobas ® CMV was 0.91 for patient samples. The Bland-Altman graph displayed a systematic bias of +0.31 log 10 for the cobas ® CMV as compared to the LDT. The bias was greater for lower CMV viral loads. This increase in CMV viral loads was not seen with testing of the CMV IS dilutions by both the LDT and cobas ® CMV. CMV VLA inter-assay commutability continues to be an issue when switching CMV testing platforms and requires communication between the laboratory and clinicians during the transition period to prevent misinterpretation of results. © 2018 Wiley Periodicals, Inc.

  4. Pulsating potentiometric titration technique for assay of dissolved oxygen in water at trace level.

    PubMed

    Sahoo, P; Ananthanarayanan, R; Malathi, N; Rajiniganth, M P; Murali, N; Swaminathan, P

    2010-06-11

    A simple but high performance potentiometric titration technique using pulsating sensors has been developed for assay of dissolved oxygen (DO) in water samples down to 10.0 microg L(-1) levels. The technique involves Winkler titration chemistry, commonly used for determination of dissolved oxygen in water at mg L(-1) levels, with modification in methodology for accurate detection of end point even at 10.0 microg L(-1) levels DO present in the sample. An indigenously built sampling cum pretreatment vessel has been deployed for collection and chemical fixing of dissolved oxygen in water samples from flowing water line without exposure to air. A potentiometric titration facility using pulsating sensors developed in-house is used to carry out titration. The power of the titration technique has been realised in estimation of very dilute solution of iodine equivalent to 10 microg L(-1) O(2). Finally, several water samples containing dissolved oxygen from mg L(-1) to microg L(-1) levels were successfully analysed with excellent reproducibility using this new technique. The precision in measurement of DO in water at 10 microg L(-1) O(2) level is 0.14 (n=5), RSD: 1.4%. Probably for the first time a potentiometric titration technique has been successfully deployed for assay of dissolved oxygen in water samples at 10 microg L(-1) levels. Copyright 2010 Elsevier B.V. All rights reserved.

  5. Miniaturization of High-Throughput Epigenetic Methyltransferase Assays with Acoustic Liquid Handling.

    PubMed

    Edwards, Bonnie; Lesnick, John; Wang, Jing; Tang, Nga; Peters, Carl

    2016-02-01

    Epigenetics continues to emerge as an important target class for drug discovery and cancer research. As programs scale to evaluate many new targets related to epigenetic expression, new tools and techniques are required to enable efficient and reproducible high-throughput epigenetic screening. Assay miniaturization increases screening throughput and reduces operating costs. Echo liquid handlers can transfer compounds, samples, reagents, and beads in submicroliter volumes to high-density assay formats using only acoustic energy-no contact or tips required. This eliminates tip costs and reduces the risk of reagent carryover. In this study, we demonstrate the miniaturization of a methyltransferase assay using Echo liquid handlers and two different assay technologies: AlphaLISA from PerkinElmer and EPIgeneous HTRF from Cisbio. © 2015 Society for Laboratory Automation and Screening.

  6. Assaying Wnt5A-mediated Invasion in Melanoma Cells

    PubMed Central

    O'Connell, Michael P.; French, Amanda D.; Leotlela, Poloko D.; Weeraratna, Ashani T.

    2009-01-01

    Wnt5A has been implicated in melanoma metastasis, and the progression of other cancers including pancreatic, gastric, prostate and lung cancers. Assays to test motility and invasion include both in vivo assays, and in vitro assays. The former assays include the use of tail vein or footpad injections of metastatic cells, and are often laborious and expensive. In vitro invasion assays provide quick readouts that can help to establish conditions that either activate or inhibit melanoma cell motility, and to assess whether the conditions in question are worth translating into an in vivo model. Here we describe two standard methods for assaying motility and invasion in vitro including wound healing assays and Matrigel invasion assays (Boyden chamber assays). In addition, we and several other laboratories have previously shown that melanoma cells require MMP-2 for their invasion, and have recently shown that Wnt5A treatment can increase the levels of this enzyme in melanoma cells, as demonstrated by gelatin zymography. The use of these techniques can help to assess the migratory capacity of melanoma cells in response to Wnt treatment. PMID:19099260

  7. Development and comparison of a real-time PCR assay for detection of Dichelobacter nodosus with culturing and conventional PCR: harmonisation between three laboratories

    PubMed Central

    2012-01-01

    Background Ovine footrot is a contagious disease with worldwide occurrence in sheep. The main causative agent is the fastidious bacterium Dichelobacter nodosus. In Scandinavia, footrot was first diagnosed in Sweden in 2004 and later also in Norway and Denmark. Clinical examination of sheep feet is fundamental to diagnosis of footrot, but D. nodosus should also be detected to confirm the diagnosis. PCR-based detection using conventional PCR has been used at our institutes, but the method was laborious and there was a need for a faster, easier-to-interpret method. The aim of this study was to develop a TaqMan-based real-time PCR assay for detection of D. nodosus and to compare its performance with culturing and conventional PCR. Methods A D. nodosus-specific TaqMan based real-time PCR assay targeting the 16S rRNA gene was designed. The inclusivity and exclusivity (specificity) of the assay was tested using 55 bacterial and two fungal strains. To evaluate the sensitivity and harmonisation of results between different laboratories, aliquots of a single DNA preparation were analysed at three Scandinavian laboratories. The developed real-time PCR assay was compared to culturing by analysing 126 samples, and to a conventional PCR method by analysing 224 samples. A selection of PCR-products was cloned and sequenced in order to verify that they had been identified correctly. Results The developed assay had a detection limit of 3.9 fg of D. nodosus genomic DNA. This result was obtained at all three laboratories and corresponds to approximately three copies of the D. nodosus genome per reaction. The assay showed 100% inclusivity and 100% exclusivity for the strains tested. The real-time PCR assay found 54.8% more positive samples than by culturing and 8% more than conventional PCR. Conclusions The developed real-time PCR assay has good specificity and sensitivity for detection of D. nodosus, and the results are easy to interpret. The method is less time-consuming than either

  8. Introducing Mammalian Cell Culture and Cell Viability Techniques in the Undergraduate Biology Laboratory.

    PubMed

    Bowey-Dellinger, Kristen; Dixon, Luke; Ackerman, Kristin; Vigueira, Cynthia; Suh, Yewseok K; Lyda, Todd; Sapp, Kelli; Grider, Michael; Crater, Dinene; Russell, Travis; Elias, Michael; Coffield, V McNeil; Segarra, Verónica A

    2017-01-01

    Undergraduate students learn about mammalian cell culture applications in introductory biology courses. However, laboratory modules are rarely designed to provide hands-on experience with mammalian cells or teach cell culture techniques, such as trypsinization and cell counting. Students are more likely to learn about cell culture using bacteria or yeast, as they are typically easier to grow, culture, and manipulate given the equipment, tools, and environment of most undergraduate biology laboratories. In contrast, the utilization of mammalian cells requires a dedicated biological safety cabinet and rigorous antiseptic techniques. For this reason, we have devised a laboratory module and method herein that familiarizes students with common cell culture procedures, without the use of a sterile hood or large cell culture facility. Students design and perform a time-efficient inquiry-based cell viability experiment using HeLa cells and tools that are readily available in an undergraduate biology laboratory. Students will become familiar with common techniques such as trypsinizing cells, cell counting with a hemocytometer, performing serial dilutions, and determining cell viability using trypan blue dye. Additionally, students will work with graphing software to analyze their data and think critically about the mechanism of death on a cellular level. Two different adaptations of this inquiry-based lab are presented-one for non-biology majors and one for biology majors. Overall, these laboratories aim to expose students to mammalian cell culture and basic techniques and help them to conceptualize their application in scientific research.

  9. Enzyme-Linked Immunosorbent Assay (ELISA).

    PubMed

    Konstantinou, George N

    2017-01-01

    Food allergy is a public health concern especially after recognizing its constantly increased prevalence and severity. Despite careful reading of food ingredient statements, food allergic individuals may experience reactions caused by "hidden", "masked", or "contaminated" proteins that are known major allergens. Many techniques have been developed to detect even small traces of food allergens, for clinical or laboratory purposes. Enzyme-linked immunosorbent assay (ELISA) is one of the best validated and most routinely used immunoassay in allergy research, in allergy diagnosis in allergy-related quality control in various industries. Although as a technique it has been implemented for the last 45 years, the evolution in biochemistry allowed the development of ultrasensitive ELISA variations that are capable of measuring quantities in the scale of picograms, rendering ELISA attractive, robust, and very famous.

  10. GHSI Emergency Radionuclide Bioassay Laboratory Network - Summary of the Second Exercise

    PubMed Central

    Li, Chunsheng; Bartizel, Christine; Battisti, Paolo; Böttger, Axel; Bouvier, Céline; Capote-Cuellar, Antonio; Carr, Zhanat; Hammond, Derek; Hartmann, Martina; Heikkinen, Tarja; Jones, Robert L.; Kim, Eunjoo; Ko, Raymond; Koga, Roberto; Kukhta, Boris; Mitchell, Lorna; Morhard, Ryan; Paquet, Francois; Quayle, Debora; Rulik, Petr; Sadi, Baki; Sergei, Aleksanin; Sierra, Inmaculada; de Oliveira Sousa, Wanderson; Szabó, Gyula

    2017-01-01

    The Global Health Security Initiative (GHSI) established a laboratory network within the GHSI community to develop collective surge capacity for radionuclide bioassay in response to a radiological or nuclear emergency as a means of enhancing response capability, health outcomes and community resilience. GHSI partners conducted an exercise in collaboration with the WHO REMPAN (Radiation Emergency Medical Preparedness and Assistance Network) and the IAEA RANET (Response and Assistance Network), to test the participating laboratories (18) for their capabilities in in vitro assay of biological samples, using a urine sample spiked with multiple high-risk radionuclides (90Sr, 106Ru, 137Cs, and 239Pu). Laboratories were required to submit their reports within 72 hours following receipt of the sample, using a pre-formatted template, on the procedures, methods and techniques used to identify and quantify the radionuclides in the sample, as well as the bioassay results with a 95% confidence interval. All of the participating laboratories identified and measured all or some of the radionuclides in the sample. However, gaps were identified in both the procedures used to assay multiple radionuclides in one sample, as well as in the methods or techniques used to assay specific radionuclides in urine. Two third of the participating laboratories had difficulties in determining all the radionuclides in the sample. Results from this exercise indicate that challenges remain with respect to ensuring that results are delivered in a timely, consistent and reliable manner to support medical interventions. Laboratories within the networks are encouraged to work together to develop and maintain collective capabilities and capacity for emergency bioassay, which is an important component of radiation emergency response. PMID:27574317

  11. Development of Techniques for Spent Fuel Assay – Differential Dieaway Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swinhoe, Martyn Thomas; Goodsell, Alison; Ianakiev, Kiril Dimitrov

    This report summarizes the work done under a DNDO R&D funded project on the development of the differential dieaway method to measure plutonium in spent fuel. There are large amounts of plutonium that are contained in spent fuel assemblies, and currently there is no way to make quantitative non-destructive assay. This has led NA24 under the Next Generation Safeguards Initiative (NGSI) to establish a multi-year program to investigate, develop and implement measurement techniques for spent fuel. The techniques which are being experimentally tested by the existing NGSI project do not include any pulsed neutron active techniques. The present work coversmore » the active neutron differential dieaway technique and has advanced the state of knowledge of this technique as well as produced a design for a practical active neutron interrogation instrument for spent fuel. Monte Carlo results from the NGSI effort show that much higher accuracy (1-2%) for the Pu content in spent fuel assemblies can be obtained with active neutron interrogation techniques than passive techniques, and this would allow their use for nuclear material accountancy independently of any information from the operator. The main purpose of this work was to develop an active neutron interrogation technique for spent nuclear fuel.« less

  12. Development and inter-laboratory assessment of droplet digital PCR assays for multiplex quantification of 15 genetically modified soybean lines.

    PubMed

    Košir, Alexandra Bogožalec; Spilsberg, Bjørn; Holst-Jensen, Arne; Žel, Jana; Dobnik, David

    2017-08-17

    Quantification of genetically modified organisms (GMOs) in food and feed products is often required for their labelling or for tolerance thresholds. Standard-curve-based simplex quantitative polymerase chain reaction (qPCR) is the prevailing technology, which is often combined with screening analysis. With the rapidly growing number of GMOs on the world market, qPCR analysis becomes laborious and expensive. Innovative cost-effective approaches are therefore urgently needed. Here, we report the development and inter-laboratory assessment of multiplex assays to quantify GMO soybean using droplet digital PCR (ddPCR). The assays were developed to facilitate testing of foods and feed for compliance with current GMO regulations in the European Union (EU). Within the EU, the threshold for labelling is 0.9% for authorised GMOs per ingredient. Furthermore, the EU has set a technical zero tolerance limit of 0.1% for certain unauthorised GMOs. The novel multiplex ddPCR assays developed target 11 GMO soybean lines that are currently authorised, and four that are tolerated, pending authorisation in the EU. Potential significant improvements in cost efficiency are demonstrated. Performance was assessed for the critical parameters, including limits of detection and quantification, and trueness, repeatability, and robustness. Inter-laboratory performance was also determined on a number of proficiency programme and real-life samples.

  13. Laboratory tests for identification or exclusion of heparin induced thrombocytopenia: HIT or miss?

    PubMed

    Favaloro, Emmanuel J

    2018-02-01

    Heparin induced thrombocytopenia (HIT) is a potentially fatal condition that arises subsequent to formation of antibodies against complexes containing heparin, usually platelet-factor 4-heparin ("anti-PF4-heparin"). Assessment for HIT involves both clinical evaluation and, if indicated, laboratory testing for confirmation or exclusion, typically using an initial immunological assay ("screening"), and only if positive, a secondary functional assay for confirmation. Many different immunological and functional assays have been developed. The most common contemporary immunological assays comprise enzyme-linked immunosorbent assay [ELISA], chemiluminescence, lateral flow, and particle gel techniques. The most common functional assays measure platelet aggregation or platelet activation events (e.g., serotonin release assay; heparin-induced platelet activation (HIPA); flow cytometry). All assays have some sensitivity and specificity to HIT antibodies, but differ in terms of relative sensitivity and specificity for pathological HIT, as well as false negative and false positive error rate. This brief article overviews the different available laboratory methods, as well as providing a suggested approach to diagnosis or exclusion of HIT. © 2017 Wiley Periodicals, Inc.

  14. Advanced yellow fever virus genome detection in point-of-care facilities and reference laboratories.

    PubMed

    Domingo, Cristina; Patel, Pranav; Yillah, Jasmin; Weidmann, Manfred; Méndez, Jairo A; Nakouné, Emmanuel Rivalyn; Niedrig, Matthias

    2012-12-01

    Reported methods for the detection of the yellow fever viral genome are beset by limitations in sensitivity, specificity, strain detection spectra, and suitability to laboratories with simple infrastructure in areas of endemicity. We describe the development of two different approaches affording sensitive and specific detection of the yellow fever genome: a real-time reverse transcription-quantitative PCR (RT-qPCR) and an isothermal protocol employing the same primer-probe set but based on helicase-dependent amplification technology (RT-tHDA). Both assays were evaluated using yellow fever cell culture supernatants as well as spiked and clinical samples. We demonstrate reliable detection by both assays of different strains of yellow fever virus with improved sensitivity and specificity. The RT-qPCR assay is a powerful tool for reference or diagnostic laboratories with real-time PCR capability, while the isothermal RT-tHDA assay represents a useful alternative to earlier amplification techniques for the molecular diagnosis of yellow fever by field or point-of-care laboratories.

  15. Immobilized Lactase in the Biochemistry Laboratory

    NASA Astrophysics Data System (ADS)

    Allison, Matthew J.; Bering, C. Larry

    1998-10-01

    Immobilized enzymes have many practical applications. They may be used in clinical, industrial, and biotechnological laboratories and in many clinical diagnostic kits. For educational purposes, use of immobilized enzymes can easily be taught at the undergraduate or even secondary level. We have developed an immobilized enzyme experiment that combines many practical techniques used in the biochemistry laboratory and fits within a three-hour time frame. In this experiment, lactase from over-the-counter tablets for patients with lactose intolerance is immobilized in polyacrylamide, which is then milled into small beads and placed into a chromatography column. A lactose solution is added to the column and the eluant is assayed using the glucose oxidase assay, available as a kit. We have determined the optimal conditions to give the greatest turnover of lactose while allowing the immobilized enzymes to be active for long periods at room temperature.

  16. An international inter-laboratory ring trial to evaluate a real-time PCR assay for the detection of bovine herpesvirus 1 in extended bovine semen.

    PubMed

    Wang, Jianning; O'Keefe, Joseph; Orr, Della; Loth, Leo; Banks, Malcolm; Wakeley, Philip; West, Donna; Card, Roderick; Ibata, Georgina; Van Maanen, Kees; Thoren, Peter; Isaksson, Mats; Kerkhofs, Pierre

    2008-01-01

    Six laboratories participated in a ring trial to evaluate the reliability of a real-time PCR assay for the detection of bovine herpesvirus 1 (BoHV-1) from extended bovine semen. Sets of coded samples were prepared and distributed to each of the laboratories. The sample panel contained semen from naturally and artificially infected bulls, serial dilutions of positive semen with negative semen, semen from uninfected seronegative bulls, negative semen spiked with virus, as well as serial dilutions of reference virus. The samples were tested using a previously validated real-time PCR assay for the detection of BoHV-1 in each participating laboratory. The PCR tests were conducted with four different real-time PCR amplification platforms, including RotorGene 3000, Stratagene MX 3000/4000, ABI 7900, and Roche LightCycler 2.0. Virus isolation using one set of samples was performed in one laboratory. The results of the laboratories were compared with one another, and with those of virus isolation. It was found that the sensitivity and specificity of the real-time PCR test was greater than those of virus isolation (82.7% versus 53.6% and 93.6% versus 84.6%, respectively). A high level of agreement on PCR testing results between the laboratories was achieved (kappa value 0.59-0.95). The results of this study indicate that the real-time PCR assay is suitable for the detection of BoHV-1 in extended semen, and would be a good substitute for the slow and laborious virus isolation, for the screening testing at artificial insemination centres and for international trade.

  17. Laboratory techniques for human embryos.

    PubMed

    Geber, Selmo; Sales, Liana; Sampaio, Marcos A C

    2002-01-01

    This review is concerned with laboratory techniques needed for assisted conception, particularly the handling of gametes and embryos. Such methods are being increasingly refined. Successive stages of fertilization and embryogenesis require especial care, and often involve the use of micromanipulative methods for intracytoplasmic sperm injection (ICSI) or preimplantation genetic diagnosis. Embryologists must take responsibility for gamete collection and preparation, and for deciding on the means of insemination or ICSI. Embryos must be assessed in culture, during the 1-cell, cleaving and morula/blastocyst stages, and classified according to quality. Co-culture methods may be necessary. The best embryos for transfer must be selected and loaded into the transfer catheter. Embryos not transferred must be cryopreserved, which demands the correct application of current methods of media preparation, seeding and the correct speed for cooling and warming. Before too long, methods of detecting abnormal embryos and avoiding their transfer may become widespread.

  18. Reduction of multi-dimensional laboratory data to a two-dimensional plot: a novel technique for the identification of laboratory error.

    PubMed

    Kazmierczak, Steven C; Leen, Todd K; Erdogmus, Deniz; Carreira-Perpinan, Miguel A

    2007-01-01

    The clinical laboratory generates large amounts of patient-specific data. Detection of errors that arise during pre-analytical, analytical, and post-analytical processes is difficult. We performed a pilot study, utilizing a multidimensional data reduction technique, to assess the utility of this method for identifying errors in laboratory data. We evaluated 13,670 individual patient records collected over a 2-month period from hospital inpatients and outpatients. We utilized those patient records that contained a complete set of 14 different biochemical analytes. We used two-dimensional generative topographic mapping to project the 14-dimensional record to a two-dimensional space. The use of a two-dimensional generative topographic mapping technique to plot multi-analyte patient data as a two-dimensional graph allows for the rapid identification of potentially anomalous data. Although we performed a retrospective analysis, this technique has the benefit of being able to assess laboratory-generated data in real time, allowing for the rapid identification and correction of anomalous data before they are released to the physician. In addition, serial laboratory multi-analyte data for an individual patient can also be plotted as a two-dimensional plot. This tool might also be useful for assessing patient wellbeing and prognosis.

  19. An investigative graduate laboratory course for teaching modern DNA techniques.

    PubMed

    de Lencastre, Alexandre; Thomas Torello, A; Keller, Lani C

    2017-07-08

    This graduate-level DNA methods laboratory course is designed to model a discovery-based research project and engages students in both traditional DNA analysis methods and modern recombinant DNA cloning techniques. In the first part of the course, students clone the Drosophila ortholog of a human disease gene of their choosing using Gateway ® cloning. In the second part of the course, students examine the expression of their gene of interest in human cell lines by reverse transcription PCR and learn how to analyze data from quantitative reverse transcription PCR (qRT-PCR) experiments. The adaptability of the Gateway ® cloning system is ideally suited for students to design and create different types of expression constructs to achieve a particular experimental goal (e.g., protein purification, expression in cell culture, and/or subcellular localization), and the genes chosen can be aligned to the research interests of the instructor and/or ongoing research in a department. Student evaluations indicate that the course fostered a genuine excitement for research and in depth knowledge of both the techniques performed and the theory behind them. Our long-term goal is to incorporate this DNA methods laboratory as the foundation for an integrated laboratory sequence for the Master of Science degree program in Molecular and Cellular Biology at Quinnipiac University, where students use the reagents and concepts they developed in this course in subsequent laboratory courses, including a protein methods and cell culture laboratory. © 2017 by The International Union of Biochemistry and Molecular Biology, 45(4):351-359, 2017. © 2017 The International Union of Biochemistry and Molecular Biology.

  20. Validation of cell-based fluorescence assays: practice guidelines from the ICSH and ICCS - part IV - postanalytic considerations.

    PubMed

    Barnett, David; Louzao, Raaul; Gambell, Peter; De, Jitakshi; Oldaker, Teri; Hanson, Curtis A

    2013-01-01

    Flow cytometry and other technologies of cell-based fluorescence assays are as a matter of good laboratory practice required to validate all assays, which when in clinical practice may pass through regulatory review processes using criteria often defined with a soluble analyte in plasma or serum samples in mind. Recently the U.S. Food and Drug Administration (FDA) has entered into a public dialogue in the U.S. regarding their regulatory interest in laboratory developed tests (LDTs) or so-called home brew assays performed in clinical laboratories. The absence of well-defined guidelines for validation of cell-based assays using fluorescence detection has thus become a subject of concern for the International Council for Standardization of Haematology (ICSH) and International Clinical Cytometry Society (ICCS). Accordingly, a group of over 40 international experts in the areas of test development, test validation, and clinical practice of a variety of assay types using flow cytometry and/or morphologic image analysis were invited to develop a set of practical guidelines useful to in vitro diagnostic (IVD) innovators, clinical laboratories, regulatory scientists, and laboratory inspectors. The focus of the group was restricted to fluorescence reporter reagents, although some common principles are shared by immunohistochemistry or immunocytochemistry techniques and noted where appropriate. The work product of this two year effort is the content of this special issue of this journal, which is published as 5 separate articles, this being Validation of Cell-based Fluorescence Assays: Practice Guidelines from the ICSH and ICCS - Part IV - Postanalytic considerations. © 2013 International Clinical Cytometry Society.

  1. Validation of cell-based fluorescence assays: practice guidelines from the ICSH and ICCS - part II - preanalytical issues.

    PubMed

    Davis, Bruce H; Dasgupta, Amar; Kussick, Steven; Han, Jin-Yeong; Estrellado, Annalee

    2013-01-01

    Flow cytometry and other technologies of cell-based fluorescence assays are as a matter of good laboratory practice required to validate all assays, which when in clinical practice may pass through regulatory review processes using criteria often defined with a soluble analyte in plasma or serum samples in mind. Recently the U.S. Food and Drug Administration (FDA) has entered into a public dialogue in the U.S. regarding their regulatory interest in laboratory developed tests (LDTs) or so-called "home brew" assays performed in clinical laboratories. The absence of well-defined guidelines for validation of cell-based assays using fluorescence detection has thus become a subject of concern for the International Council for Standardization of Haematology (ICSH) and International Clinical Cytometry Society (ICCS). Accordingly, a group of over 40 international experts in the areas of test development, test validation, and clinical practice of a variety of assay types using flow cytometry and/or morphologic image analysis were invited to develop a set of practical guidelines useful to in vitro diagnostic (IVD) innovators, clinical laboratories, regulatory scientists, and laboratory inspectors. The focus of the group was restricted to fluorescence reporter reagents, although some common principles are shared by immunohistochemistry or immunocytochemistry techniques and noted where appropriate. The work product of this two year effort is the content of this special issue of this journal, which is published as 5 separate articles, this being Validation of Cell-based Fluorescence Assays: Practice Guidelines from the ICSH and ICCS - Part II - Preanalytical issues. © 2013 International Clinical Cytometry Society. © 2013 International Clinical Cytometry Society.

  2. Inflammation Thread Runs across Medical Laboratory Specialities

    PubMed Central

    Lung, Thomas; Risch, Lorenz; Risch, Martin; Medina Escobar, Pedro; Bodmer, Thomas

    2016-01-01

    We work on the assumption that four major specialities or sectors of medical laboratory assays, comprising clinical chemistry, haematology, immunology, and microbiology, embraced by genome sequencing techniques, are routinely in use. Medical laboratory markers for inflammation serve as model: they are allotted to most fields of medical lab assays including genomics. Incessant coding of assays aligns each of them in the long lists of big data. As exemplified with the complement gene family, containing C2, C3, C8A, C8B, CFH, CFI, and ITGB2, heritability patterns/risk factors associated with diseases with genetic glitch of complement components are unfolding. The C4 component serum levels depend on sufficient vitamin D whilst low vitamin D is inversely related to IgG1, IgA, and C3 linking vitamin sufficiency to innate immunity. Whole genome sequencing of microbial organisms may distinguish virulent from nonvirulent and antibiotic resistant from nonresistant varieties of the same species and thus can be listed in personal big data banks including microbiological pathology; the big data warehouse continues to grow. PMID:27493451

  3. Inflammation Thread Runs across Medical Laboratory Specialities.

    PubMed

    Nydegger, Urs; Lung, Thomas; Risch, Lorenz; Risch, Martin; Medina Escobar, Pedro; Bodmer, Thomas

    2016-01-01

    We work on the assumption that four major specialities or sectors of medical laboratory assays, comprising clinical chemistry, haematology, immunology, and microbiology, embraced by genome sequencing techniques, are routinely in use. Medical laboratory markers for inflammation serve as model: they are allotted to most fields of medical lab assays including genomics. Incessant coding of assays aligns each of them in the long lists of big data. As exemplified with the complement gene family, containing C2, C3, C8A, C8B, CFH, CFI, and ITGB2, heritability patterns/risk factors associated with diseases with genetic glitch of complement components are unfolding. The C4 component serum levels depend on sufficient vitamin D whilst low vitamin D is inversely related to IgG1, IgA, and C3 linking vitamin sufficiency to innate immunity. Whole genome sequencing of microbial organisms may distinguish virulent from nonvirulent and antibiotic resistant from nonresistant varieties of the same species and thus can be listed in personal big data banks including microbiological pathology; the big data warehouse continues to grow.

  4. Multicentric comparative assessment of the bio-evolution Toxoplasma gondii detection kit with eight laboratory-developed PCR assays for molecular diagnosis of congenital toxoplasmosis.

    PubMed

    Filisetti, Denis; Sterkers, Yvon; Brenier-Pinchart, Marie-Pierre; Cassaing, Sophie; Dalle, Frédéric; Delhaes, Laurence; Pelloux, Hervé; Touafek, Fériel; Varlet-Marie, Emmanuelle; Yera, Hélène; Candolfi, Ermano; Bastien, Patrick

    2015-01-01

    The detection of Toxoplasma gondii in amniotic fluid is an essential tool for the prenatal diagnosis of congenital toxoplasmosis and is currently essentially based on the use of PCR. Although some consensus is emerging, this molecular diagnosis suffers from a lack of standardization and an extreme diversity of laboratory-developed methods. Commercial kits for the detection of T. gondii by PCR were recently developed and offer certain advantages; however, they must be assessed in comparison with optimized reference PCR assays. The present multicentric study aimed to compare the performances of the Bio-Evolution T. gondii detection kit and laboratory-developed PCR assays set up in eight proficient centers in France. The study compared 157 amniotic fluid samples and found concordances of 99% and 100% using 76 T. gondii-infected samples and 81 uninfected samples, respectively. Moreover, taking into account the classification of the European Research Network on Congenital Toxoplasmosis, the overall diagnostic sensitivity of all assays was identical and calculated to be 86% (54/63); specificity was 100% for all assays. Finally, the relative quantification results were in good agreement between the kit and the laboratory-developed assays. The good performances of this commercial kit are probably in part linked to the use of a number of good practices: detection in multiplicate, amplification of the repetitive DNA target rep529, and the use of an internal control for the detection of PCR inhibitors. The only drawbacks noted at the time of the study were the absence of uracil-N-glycosylase and small defects in the reliability of the production of different reagents. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  5. Multicentric Comparative Assessment of the Bio-Evolution Toxoplasma gondii Detection Kit with Eight Laboratory-Developed PCR Assays for Molecular Diagnosis of Congenital Toxoplasmosis

    PubMed Central

    Filisetti, Denis; Sterkers, Yvon; Brenier-Pinchart, Marie-Pierre; Cassaing, Sophie; Dalle, Frédéric; Delhaes, Laurence; Pelloux, Hervé; Touafek, Fériel; Varlet-Marie, Emmanuelle; Yera, Hélène; Candolfi, Ermano

    2014-01-01

    The detection of Toxoplasma gondii in amniotic fluid is an essential tool for the prenatal diagnosis of congenital toxoplasmosis and is currently essentially based on the use of PCR. Although some consensus is emerging, this molecular diagnosis suffers from a lack of standardization and an extreme diversity of laboratory-developed methods. Commercial kits for the detection of T. gondii by PCR were recently developed and offer certain advantages; however, they must be assessed in comparison with optimized reference PCR assays. The present multicentric study aimed to compare the performances of the Bio-Evolution T. gondii detection kit and laboratory-developed PCR assays set up in eight proficient centers in France. The study compared 157 amniotic fluid samples and found concordances of 99% and 100% using 76 T. gondii-infected samples and 81 uninfected samples, respectively. Moreover, taking into account the classification of the European Research Network on Congenital Toxoplasmosis, the overall diagnostic sensitivity of all assays was identical and calculated to be 86% (54/63); specificity was 100% for all assays. Finally, the relative quantification results were in good agreement between the kit and the laboratory-developed assays. The good performances of this commercial kit are probably in part linked to the use of a number of good practices: detection in multiplicate, amplification of the repetitive DNA target rep529, and the use of an internal control for the detection of PCR inhibitors. The only drawbacks noted at the time of the study were the absence of uracil-N-glycosylase and small defects in the reliability of the production of different reagents. PMID:25339393

  6. Miniature silicon electronic biological assay chip and applications for rapid battlefield diagnostics

    NASA Astrophysics Data System (ADS)

    Cunningham, Brian T.; Regan, Robert A.; Clapp, Christopher; Hildebrant, Eric; Weinberg, Marc S.; Williams, John

    1999-07-01

    Assessing the medical condition of battlefield personnel requires the development of rapid, portable biological diagnostic assays for a wide variety of antigens and enzymes. Ideally, such an assay would be inexpensive, small, and require no added reagents while maintaining the sensitivity and accuracy of laboratory-based assays. In this work, a microelectromechanical (MEMS) based biological assay sensor is presented which is expected to meet the above requirements. The sensor is a thin silicon membrane resonator (SMR) which registers a decrease in resonant frequency when mass is adsorbed onto its surface. By coating the sensor surface with a monolayer of antibody, for example, we have detected the corresponding antigen with a detection resolution of 0.25 ng/ml in phosphate buffer solution. Micromachining techniques are being used to integrate many (64 elements on the first test chip) identical SMR sensors into a single silicon chip which would be capable of simultaneously performing a wide variety of biomedical assays. The sensors require only a small printed circuit board and 8V power supply to operate and provide a readout. The presentation will describe the operation of the SMR sensor, the fabrication of the sensor array, and initial test results using commercially available animal immunoglobulins in laboratory-prepared test solutions.

  7. Nonculture molecular techniques for diagnosis of bacterial disease in animals: a diagnostic laboratory perspective.

    PubMed

    Cai, H Y; Caswell, J L; Prescott, J F

    2014-03-01

    The past decade has seen remarkable technical advances in infectious disease diagnosis, and the pace of innovation is likely to continue. Many of these techniques are well suited to pathogen identification directly from pathologic or clinical samples, which is the focus of this review. Polymerase chain reaction (PCR) and gene sequencing are now routinely performed on frozen or fixed tissues for diagnosis of bacterial infections of animals. These assays are most useful for pathogens that are difficult to culture or identify phenotypically, when propagation poses a biosafety hazard, or when suitable fresh tissue is not available. Multiplex PCR assays, DNA microarrays, in situ hybridization, massive parallel DNA sequencing, microbiome profiling, molecular typing of pathogens, identification of antimicrobial resistance genes, and mass spectrometry are additional emerging technologies for the diagnosis of bacterial infections from pathologic and clinical samples in animals. These technical advances come, however, with 2 caveats. First, in the age of molecular diagnosis, quality control has become more important than ever to identify and control for the presence of inhibitors, cross-contamination, inadequate templates from diagnostic specimens, and other causes of erroneous microbial identifications. Second, the attraction of these technologic advances can obscure the reality that medical diagnoses cannot be made on the basis of molecular testing alone but instead through integrated consideration of clinical, pathologic, and laboratory findings. Proper validation of the method is required. It is critical that veterinary diagnosticians understand not only the value but also the limitations of these technical advances for routine diagnosis of infectious disease.

  8. The Effect of Jigsaw Technique on the Students' Laboratory Material Recognition and Usage Skills in General Physics Laboratory-I Course

    ERIC Educational Resources Information Center

    Aydin, Abdullah; Biyikli, Filiz

    2017-01-01

    This research aims to compare the effects of Jigsaw technique from the cooperative learning methods and traditional learning method on laboratory material recognition and usage skills of students in General Physics Lab-I Course. This study was conducted with 63 students who took general physics laboratory-I course in the department of science…

  9. Introducing Mammalian Cell Culture and Cell Viability Techniques in the Undergraduate Biology Laboratory

    PubMed Central

    Bowey-Dellinger, Kristen; Dixon, Luke; Ackerman, Kristin; Vigueira, Cynthia; Suh, Yewseok K.; Lyda, Todd; Sapp, Kelli; Grider, Michael; Crater, Dinene; Russell, Travis; Elias, Michael; Coffield, V. McNeil; Segarra, Verónica A.

    2017-01-01

    Undergraduate students learn about mammalian cell culture applications in introductory biology courses. However, laboratory modules are rarely designed to provide hands-on experience with mammalian cells or teach cell culture techniques, such as trypsinization and cell counting. Students are more likely to learn about cell culture using bacteria or yeast, as they are typically easier to grow, culture, and manipulate given the equipment, tools, and environment of most undergraduate biology laboratories. In contrast, the utilization of mammalian cells requires a dedicated biological safety cabinet and rigorous antiseptic techniques. For this reason, we have devised a laboratory module and method herein that familiarizes students with common cell culture procedures, without the use of a sterile hood or large cell culture facility. Students design and perform a time-efficient inquiry-based cell viability experiment using HeLa cells and tools that are readily available in an undergraduate biology laboratory. Students will become familiar with common techniques such as trypsinizing cells, cell counting with a hemocytometer, performing serial dilutions, and determining cell viability using trypan blue dye. Additionally, students will work with graphing software to analyze their data and think critically about the mechanism of death on a cellular level. Two different adaptations of this inquiry-based lab are presented—one for non-biology majors and one for biology majors. Overall, these laboratories aim to expose students to mammalian cell culture and basic techniques and help them to conceptualize their application in scientific research. PMID:28861134

  10. In Situ Techniques for Monitoring Electrochromism: An Advanced Laboratory Experiment

    ERIC Educational Resources Information Center

    Saricayir, Hakan; Uce, Musa; Koca, Atif

    2010-01-01

    This experiment employs current technology to enhance and extend existing lab content. The basic principles of spectroscopic and electroanalytical techniques and their use in determining material properties are covered in some detail in many undergraduate chemistry programs. However, there are limited examples of laboratory experiments with in…

  11. Validation of cell-based fluorescence assays: practice guidelines from the ICSH and ICCS - part I - rationale and aims.

    PubMed

    Davis, Bruce H; Wood, Brent; Oldaker, Teri; Barnett, David

    2013-01-01

    Flow cytometry and other technologies of cell-based fluorescence assays are as a matter of good laboratory practice required to validate all assays, which when in clinical practice may pass through regulatory review processes using criteria often defined with a soluble analyte in plasma or serum samples in mind. Recently the U.S. Food and Drug Administration (FDA) has entered into a public dialogue in the U.S. regarding their regulatory interest in laboratory developed tests (LDTs) or so-called "home brew" assays performed in clinical laboratories. The absence of well-defined guidelines for validation of cell-based assays using fluorescence detection has thus become a subject of concern for the International Council for Standardization of Haematology (ICSH) and International Clinical Cytometry Society (ICCS). Accordingly, a group of over 40 international experts in the areas of test development, test validation, and clinical practice of a variety of assay types using flow cytometry and/or morphologic image analysis were invited to develop a set of practical guidelines useful to in vitro diagnostic (IVD) innovators, clinical laboratories, regulatory scientists, and laboratory inspectors. The focus of the group was restricted to fluorescence reporter reagents, although some common principles are shared by immunohistochemistry or immunocytochemistry techniques and noted where appropriate. The work product of this two year effort is the content of this special issue of this journal, which is published as 5 separate articles, this being Validation of Cell-based Fluorescence Assays: Practice Guidelines from the ICSH and ICCS - Part I - Rationale and aims. © 2013 International Clinical Cytometry Society. © 2013 International Clinical Cytometry Society.

  12. Simple and rapid system for two-dimensional gel electrophoresis technique: A laboratory exercise for high school students.

    PubMed

    Maurye, Praveen; Basu, Arpita; Biswas, Jayanta Kumar; Bandyopadhyay, Tapas Kumar; Naskar, Malay

    2018-02-28

    Polyacrylamide gel electrophoresis (PAGE) is the most classical technique favored worldwide for resolution of macromolecules in many biochemistry laboratories due to its incessant advanced developments and wide modifications. These ever-growing advancements in the basic laboratory equipments lead to emergence of many expensive, complex, and tricky laboratory equipments. Practical courses of biochemistry at high school or undergraduate levels are often affected by these complications. Two dimensional gel electrophoresis technique (2D-PAGE) used for resolving thousands of proteins in a gel is a combination of isoelectric focusing (first dimension gel electrophoresis technique) and sodium-dodecylsulphate PAGE (second dimension gel electrophoresis technique or SDS-PAGE). Two different laboratory equipments are needed to carry out effective 2D-PAGE technique, which also invites extra burden to the school laboratory. Here, we describe a low cost, time saving and simple gel cassette for protein 2D-PAGE technique that uses easily fabricated components and routine off-the-shelf materials. The performance of the apparatus was verified in a practical exercise by a group of high school students with positive outcomes. © 2018 by The International Union of Biochemistry and Molecular Biology, 2018. © 2018 The International Union of Biochemistry and Molecular Biology.

  13. GHSI EMERGENCY RADIONUCLIDE BIOASSAY LABORATORY NETWORK - SUMMARY OF THE SECOND EXERCISE.

    PubMed

    Li, Chunsheng; Bartizel, Christine; Battisti, Paolo; Böttger, Axel; Bouvier, Céline; Capote-Cuellar, Antonio; Carr, Zhanat; Hammond, Derek; Hartmann, Martina; Heikkinen, Tarja; Jones, Robert L; Kim, Eunjoo; Ko, Raymond; Koga, Roberto; Kukhta, Boris; Mitchell, Lorna; Morhard, Ryan; Paquet, Francois; Quayle, Debora; Rulik, Petr; Sadi, Baki; Sergei, Aleksanin; Sierra, Inmaculada; de Oliveira Sousa, Wanderson; Szab, Gyula

    2017-05-01

    The Global Health Security Initiative (GHSI) established a laboratory network within the GHSI community to develop collective surge capacity for radionuclide bioassay in response to a radiological or nuclear emergency as a means of enhancing response capability, health outcomes and community resilience. GHSI partners conducted an exercise in collaboration with the WHO Radiation Emergency Medical Preparedness and Assistance Network and the IAEA Response and Assistance Network, to test the participating laboratories (18) for their capabilities in in vitro assay of biological samples, using a urine sample spiked with multiple high-risk radionuclides (90Sr, 106Ru, 137Cs, and 239Pu). Laboratories were required to submit their reports within 72 h following receipt of the sample, using a pre-formatted template, on the procedures, methods and techniques used to identify and quantify the radionuclides in the sample, as well as the bioassay results with a 95% confidence interval. All of the participating laboratories identified and measured all or some of the radionuclides in the sample. However, gaps were identified in both the procedures used to assay multiple radionuclides in one sample, as well as in the methods or techniques used to assay specific radionuclides in urine. Two-third of the participating laboratories had difficulties in determining all the radionuclides in the sample. Results from this exercise indicate that challenges remain with respect to ensuring that results are delivered in a timely, consistent and reliable manner to support medical interventions. Laboratories within the networks are encouraged to work together to develop and maintain collective capabilities and capacity for emergency bioassay, which is an important component of radiation emergency response. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Orthodontic soldering techniques: aspects of quality assurance in the dental laboratory.

    PubMed

    Heidemann, Jutta; Witt, Emil; Feeg, Martin; Werz, Rainer; Pieger, Klaus

    2002-07-01

    In Germany, the dental technician is required by the Medical Products Act (MPG) to produce workpieces of high safety and quality and to document these properties. Soldering continues to be the prevailing joining technique in the dental laboratory, although problems arise from the susceptibility to corrosion and the low strength of soldered joints. This study aimed to reveal sources of defects in dental laboratory workpieces in order to achieve optimization in terms of quality assurance. The joints were produced by various dental technicians using three different soldering techniques. These joining techniques were investigated for their quality and their corrosion properties during immersion in ferric chloride, orthodontic appliance cleanser, and artificial saliva. Observance of the soldering instructions by the dental technicians was checked. Corrosion attack was confirmed by scanning electron microscopy and by measuring the ion concentrations of copper, silver and zinc in the corrosive agents, using atomic emission spectroscopy with stimulation by inductively coupled plasma (ICP-AES analysis). Incomplete filling of the soldering gap, porosities resulting from the production process, poor corrosion properties, and in particular a high variability of the measured values point to insufficient reliability of two soldering techniques. Variations in quality were also detected among the technicians' modes of operation. The analyses confirm the need for quality assurance of soldering techniques and for increased support for alternative joining techniques such as laser welding in the future. The results of the studies on laser welding are presented in a separate publication.

  15. Laboratory Diagnosis and Characterization of Fungal Disease in Patients with Cystic Fibrosis (CF): A Survey of Current UK Practice in a Cohort of Clinical Microbiology Laboratories.

    PubMed

    Boyle, Maeve; Moore, John E; Whitehouse, Joanna L; Bilton, Diana; Downey, Damian G

    2018-03-02

    There is much uncertainty as to how fungal disease is diagnosed and characterized in patients with cystic fibrosis (CF). A 19-question anonymous electronic questionnaire was developed and distributed to ascertain current practice in clinical microbiology laboratories providing a fungal laboratory service to CF centres in the UK. Analyses of responses identified the following: (1) current UK laboratory practice, in general, follows the current guidelines, but the scope and diversity of what is currently being delivered by laboratories far exceeds what is detailed in the guidelines; (2) there is a lack of standardization of fungal tests amongst laboratories, outside of the current guidelines; (3) both the UK CF Trust Laboratory Standards for Processing Microbiological Samples from People with Cystic Fibrosis and the US Cumulative Techniques and Procedures in Clinical Microbiology (Cumitech) Guidelines 43 Cystic Fibrosis Microbiology need to be updated to reflect both new methodological innovations, as well as better knowledge of fungal disease pathophysiology in CF; (4) there is a need for clinical medicine to decide upon a stratification strategy for the provision of new fungal assays that will add value to the physician in the optimal management of CF patients; (5) there is also a need to rationale what assays should be performed at local laboratory level and those which are best served at National Mycology Reference Laboratory level; and (6) further research is required in developing laboratory assays, which will help ascertain the clinical importance of 'old' fungal pathogens, as well as 'emerging' fungal pathogens.

  16. ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION USING THE DOUBLE-BUNDLE TECHNIQUE - EVALUATION IN THE BIOMECHANICS LABORATORY.

    PubMed

    D'Elia, Caio Oliveira; Bitar, Alexandre Carneiro; Castropil, Wagner; Garofo, Antônio Guilherme Padovani; Cantuária, Anita Lopes; Orselli, Maria Isabel Veras; Luques, Isabela Ugo; Duarte, Marcos

    2011-01-01

    The objective of this study was to describe the methodology of knee rotation analysis using biomechanics laboratory instruments and to present the preliminary results from a comparative study on patients who underwent anterior cruciate ligament (ACL) reconstruction using the double-bundle technique. The protocol currently used in our laboratory was described. Three-dimensional kinematic analysis was performed and knee rotation amplitude was measured on eight normal patients (control group) and 12 patients who were operated using the double-bundle technique, by means of three tasks in the biomechanics laboratory. No significant differences between operated and non-operated sides were shown in relation to the mean amplitudes of gait, gait with change in direction or gait with change in direction when going down stairs (p > 0.13). The preliminary results did not show any difference in the double-bundle ACL reconstruction technique in relation to the contralateral side and the control group.

  17. Laboratory techniques in plant molecular biology taught with UniformMu insertion alleles of maize

    USDA-ARS?s Scientific Manuscript database

    An undergraduate course - Laboratory Techniques in Plant Molecular Biology - was organized around our research application of UniformMu insertion alleles to investigate mitochondrial functions in plant reproduction. The course objectives were to develop students’ laboratory, record keeping, bioinfor...

  18. Acoustic Emission Detected by Matched Filter Technique in Laboratory Earthquake Experiment

    NASA Astrophysics Data System (ADS)

    Wang, B.; Hou, J.; Xie, F.; Ren, Y.

    2017-12-01

    Acoustic Emission in laboratory earthquake experiment is a fundamental measures to study the mechanics of the earthquake for instance to characterize the aseismic, nucleation, as well as post seismic phase or in stick slip experiment. Compared to field earthquake, AEs are generally recorded when they are beyond threshold, so some weak signals may be missing. Here we conducted an experiment on a 1.1m×1.1m granite with a 1.5m fault and 13 receivers with the same sample rate of 3MHz are placed on the surface. We adopt continues record and a matched filter technique to detect low-SNR signals. We found there are too many signals around the stick-slip and the P- arrival picked by manual may be time-consuming. So, we combined the short-term average to long-tem-average ratio (STA/LTA) technique with Autoregressive-Akaike information criterion (AR-AIC) technique to pick the arrival automatically and found mostly of the P- arrival accuracy can satisfy our demand to locate signals. Furthermore, we will locate the signals and apply a matched filter technique to detect low-SNR signals. Then, we can see if there is something interesting in laboratory earthquake experiment. Detailed and updated results will be present in the meeting.

  19. Pathology consultation on anticoagulation monitoring: factor X-related assays.

    PubMed

    Wool, Geoffrey D; Lu, Chuanyi M

    2013-11-01

    To review various anticoagulation therapies and related laboratory monitoring issues, with a focus on factor X-related chromogenic assays. A case-based approach is used to review pertinent published literatures and product inserts of anticoagulation drugs and to look back on clinical use of factor X-related chromogenic assays. The number of anticoagulants available to clinicians has increased greatly in the past decade. Whether and how these anticoagulants should be monitored are areas of uncertainty for clinicians, which can lead to misuse of laboratory assays and suboptimal patient management. Factor X-related assays are of particular concern because of the similar and often confusing test names. Based on a common clinical case scenario and literature review regarding anticoagulant monitoring, an up-to-date discussion and review of the various factor X-related assays are provided, focusing on the differences in test designs and clinical utilities between the chromogenic anti-Xa and chromogenic factor X activity assays. Anticoagulation therapy and related laboratory monitoring are rapidly evolving areas of clinical practices. A good knowledge of relevant laboratory assays and their clinical applications is necessary to help optimize patient care.

  20. An Investigative Graduate Laboratory Course for Teaching Modern DNA Techniques

    ERIC Educational Resources Information Center

    de Lencastre, Alexandre; Torello, A. Thomas; Keller, Lani C.

    2017-01-01

    This graduate-level DNA methods laboratory course is designed to model a discovery-based research project and engages students in both traditional DNA analysis methods and modern recombinant DNA cloning techniques. In the first part of the course, students clone the "Drosophila" ortholog of a human disease gene of their choosing using…

  1. Evaluation of the Roche prototype 454 HIV-1 ultradeep sequencing drug resistance assay in a routine diagnostic laboratory.

    PubMed

    Garcia-Diaz, A; Guerrero-Ramos, A; McCormick, A L; Macartney, M; Conibear, T; Johnson, M A; Haque, T; Webster, D P

    2013-10-01

    Studies have shown that low-frequency resistance mutations can influence treatment outcome. However, the lack of a standardized high-throughput assay has precluded their detection in clinical settings. To evaluate the performance of the Roche prototype 454 UDS HIV-1 drug resistance assay (UDS assay) in a routine diagnostic laboratory. 50 plasma samples, previously characterized by population sequencing and that had shown ≥1 resistance associated mutation (RAM), were retrospectively tested by the UDS assay, including 18 B and 32 non-B subtypes; viral loads between 114-1,806,407 cp/ml; drug-naive (n=27) and drug-experienced (n=23) individuals. The UDS assay was successful for 37/50 (74%) samples. It detected all RAMs found by population sequencing at frequencies above 20%. In addition, 39 low-frequency RAMs were exclusively detected by the UDS assay at frequencies below 20% in both drug-naïve (19/26, 73%) and drug-experienced (9/18, 50%) individuals. UDS results would lead to changes from susceptible to resistant to efavirenz (EFV) in one drug-naive individual with suboptimal response to an EFV-containing regimen and from susceptible to resistance to lamivudine (3TC) in one drug naïve subject who subsequently failed a 3TC-containing regimen and in a treatment experienced subject who had failed a 3TC-containing regimen. The UDS assay performed well across a wide range of subtypes and viral loads; it showed perfect agreement with population sequencing for all RAMs analyzed. In addition, the UDS assay detected additional mutations at frequencies below 20% which correlate with patients' treatment history and had in some cases important prognostic implications. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. A bispecific antibody based assay shows potential for detecting tuberculosis in resource constrained laboratory settings.

    PubMed

    Sarkar, Susmita; Tang, Xinli L; Das, Dipankar; Spencer, John S; Lowary, Todd L; Suresh, Mavanur R

    2012-01-01

    The re-emergence of tuberculosis (TB) as a global public health threat highlights the necessity of rapid, simple and inexpensive point-of-care detection of the disease. Early diagnosis of TB is vital not only for preventing the spread of the disease but also for timely initiation of treatment. The later in turn will reduce the possible emergence of multi-drug resistant strains of Mycobacterium tuberculosis. Lipoarabinomannan (LAM) is an important non-protein antigen of the bacterial cell wall, which is found to be present in different body fluids of infected patients including blood, urine and sputum. We have developed a bispecific monoclonal antibody with predetermined specificities towards the LAM antigen and a reporter molecule horseradish peroxidase (HRPO). The developed antibody was subsequently used to design a simple low cost immunoswab based assay to detect LAM antigen. The limit of detection for spiked synthetic LAM was found to be 5.0 ng/ml (bovine urine), 0.5 ng/ml (rabbit serum) and 0.005 ng/ml (saline) and that for bacterial LAM from M. tuberculosis H37Rv was found to be 0.5 ng/ml (rabbit serum). The assay was evaluated with 21 stored clinical serum samples (14 were positive and 7 were negative in terms of anti-LAM titer). In addition, all 14 positive samples were culture positive. The assay showed 100% specificity and 64% sensitivity (95% confidence interval). In addition to good specificity, the end point could be read visually within two hours of sample collection. The reported assay might be used as a rapid tool for detecting TB in resource constrained laboratory settings.

  3. Glycobiology, how to sugar-coat an undergraduate advanced biochemistry laboratory.

    PubMed

    McReynolds, Katherine D

    2006-09-01

    A second semester biochemistry laboratory has been implemented as an independent projects course at California State University, Sacramento since 1999. To incorporate aspects of carbohydrate biochemistry, or glycobiology, into our curriculum, projects in lectin isolation and purification were undertaken over the course of two semesters. Through this modification in course content, this class now offers a diverse, hands-on treatment of not only standard protein purification techniques but also carbohydrate techniques, specifically the study of carbohydrate-protein interactions through hemagglutination assays, a novel commercial assay known as the Instant™Chek assay, and the generation and use of appropriate affinity chromatography matrices. Throughout the semester, the students are in charge of all aspects of their projects, from planning to execution and completion. Specific examples of student projects are highlighted such that the breadth of protein-carbohydrate chemistry pursued in a 15-week semester can be appreciated. The feedback of the course was very favorable, indicating that the students came away with skills necessary for them to be successful in their future careers. Most importantly, however, aspects of glycobiology have now been incorporated effectively into a mainstream undergraduate biochemistry laboratory class. Copyright © 2006 International Union of Biochemistry and Molecular Biology, Inc.

  4. Modified RS-LAMP assay and use of lateral flow devices for rapid detection of Leifsonia xyli subsp. xyli.

    PubMed

    Naidoo, N; Ghai, M; Moodley, K; Mkize, L; Martin, L; McFarlane, S; Rutherford, S

    2017-12-01

    Ratoon stunt (RS) caused by bacterium Leifsonia xyli subsp. xyli (Lxx) results in substantial yield losses in sugarcane (Saccharum sp. L. hybrid). Since RS does not produce reliable symptoms in the field, laboratory-based techniques are necessary for detection. Loop-mediated isothermal amplification (LAMP) assay overcomes the limitations of laboratory-based techniques which are costly, time consuming and cannot be used for near-field detection. A sensitive LAMP assay was developed to detect Lxx at 65°C in 30 min. However, carry-over contamination affected the reliability of the assay. In the present study, contaminants were successfully eliminated by incorporation of uracil nucleoside glycosylase (1 U μl -1 ) into the LAMP assay and incubation for 10 min at 37°C. To avoid the use of colorimetric reagents, lateral flow devices were successfully used for the detection of LAMP products and were equally sensitive to detection by agarose gel electrophoresis. The use of exudate from leaf sheath discs as an alternate template for the LAMP assay was found to be less sensitive than xylem sap. The preprepared master mix could be stored for up to 4 months at -20°C without any reduction in performance. These changes make the assay suitable for near-field detection in laboratories with basic facilities. This study presents a modified loop-mediated isothermal amplification (LAMP) assay for the detection of Leifsonia xyli subsp. xyli. Modifications include incorporation of uracil nucleoside glycosylase to eliminate carry-over contamination and substitution of colorimetric detection for the use of lateral flow devices. LAMP master mix was preprepared and was stably stored up to 4 months at -20°C. Sugarcane leaf sheaths worked well as a substitute to xylem sap as template, although the sensitivity was lower. These modifications allow the assay to be conducted without contamination concerns and reduction in set up time, making it ideal for near-field diagnosis. © 2017

  5. Revitalizing pathology laboratories in a gastrointestinal pathophysiology course using multimedia and team-based learning techniques.

    PubMed

    Carbo, Alexander R; Blanco, Paola G; Graeme-Cooke, Fiona; Misdraji, Joseph; Kappler, Steven; Shaffer, Kitt; Goldsmith, Jeffrey D; Berzin, Tyler; Leffler, Daniel; Najarian, Robert; Sepe, Paul; Kaplan, Jennifer; Pitman, Martha; Goldman, Harvey; Pelletier, Stephen; Hayward, Jane N; Shields, Helen M

    2012-05-15

    In 2008, we changed the gastrointestinal pathology laboratories in a gastrointestinal pathophysiology course to a more interactive format using modified team-based learning techniques and multimedia presentations. The results were remarkably positive and can be used as a model for pathology laboratory improvement in any organ system. Over a two-year period, engaging and interactive pathology laboratories were designed. The initial restructuring of the laboratories included new case material, Digital Atlas of Video Education Project videos, animations and overlays. Subsequent changes included USMLE board-style quizzes at the beginning of each laboratory, with individual readiness assessment testing and group readiness assessment testing, incorporation of a clinician as a co-teacher and role playing for the student groups. Student responses for pathology laboratory contribution to learning improved significantly compared to baseline. Increased voluntary attendance at pathology laboratories was observed. Spontaneous student comments noted the positive impact of the laboratories on their learning. Pathology laboratory innovations, including modified team-based learning techniques with individual and group self-assessment quizzes, multimedia presentations, and paired teaching by a pathologist and clinical gastroenterologist led to improvement in student perceptions of pathology laboratory contributions to their learning and better pathology faculty evaluations. These changes can be universally applied to other pathology laboratories to improve student satisfaction. Copyright © 2012 Elsevier GmbH. All rights reserved.

  6. The Effectiveness of Active and Traditional Teaching Techniques in the Orthopedic Assessment Laboratory

    ERIC Educational Resources Information Center

    Nottingham, Sara; Verscheure, Susan

    2010-01-01

    Active learning is a teaching methodology with a focus on student-centered learning that engages students in the educational process. This study implemented active learning techniques in an orthopedic assessment laboratory, and the effects of these teaching techniques. Mean scores from written exams, practical exams, and final course evaluations…

  7. Adaptation of the ORAC assay to the common laboratory equipment and subsequent application to antioxidant plastic films.

    PubMed

    Bentayeb, K; Vera, P; Rubio, C; Nerin, C

    2009-06-01

    The oxygen radical absorbance capacity (ORAC) method has been adapted to the instrumental laboratory and optimized for the determination of the antioxidant capacity of a novel active packaging. As the ORAC assay requires the monitorization of a reaction at controlled temperature by means of the fluorescence signal decrease over time, specific instrumental is usually necessary. In this work, a common liquid chromatographic device has been adapted to perform the ORAC assay, leaving it accessible to any laboratory. Using this adaptation, five different essential oils have been determined resulting in the following antioxidant order: clove (2.66 g Trolox per gram of essential oil), oregano (2.25), cinnamon (1.93), rosemary (1.66), and ginger (1.47). After incorporating the essential oils to the film, its antioxidant capacity has also been checked and related to the concentration of essential oil as well as the thickness of the active film. The results point out that for the same amount of essential oil incorporated measured as grams per square meter, thicker films have more antioxidant capacity than the thinner and more concentrated ones. Furthermore, the antioxidant capacity found in the films was always higher than expected taking into account the amount of essential oil incorporated. Some likely explanations have been proposed, leading to the improvement of the antioxidant film under development.

  8. [Assays of HbA1c and Amadori products in human biology].

    PubMed

    Gillery, P

    2014-09-01

    Different Amadori products, formed during the early steps of the non-enzymatic glycation of proteins, may be assayed in current practice in human biology. The most important marker is HbA1c, resulting from the binding of glucose to the N-terminal extremity of HbA beta chains. HbA1c may be evaluated by various techniques (ion exchange or affinity high performance liquid chromatography, capillary electrophoresis, immunoassay, enzymatic technique) and is considered the best marker of diabetic patient survey. Due to its irreversible and cumulative formation, it provides a retrospective information on the glycemic balance over the four to eight weeks preceding blood collection. It benefits from an international standardization, based on a reference method using liquid chromatography coupled to capillary electrophoresis or mass spectrometry, maintained by an international network of reference laboratories. When HbA1c assay cannot be used (anemia, hemolysis, hemoglobinopathy) or when a shorter period of glycemic equilibrium must be evaluated (child and adolescent, pregnancy, therapeutic changes), other Amadori products may be assayed, like plasma fructosamine (all plasma glycated proteins) or glycated albumin. Nevertheless, these assays are less used in practice, because their semiological value has been less evidenced. Besides, fructosamine assay lacks specificity, and glycated albumin assay has been described recently. An expanding use of HbA1c assay is expected, especially for the diagnosis of diabetes mellitus and the evaluation of other risks, especially cardiovascular ones. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  9. Case report of Salmonella cross-contamination in a food laboratory.

    PubMed

    Rasschaert, Geertrui; De Reu, K; Heyndrickx, M; Herman, L

    2016-03-10

    This paper describes a case of Salmonella cross-contamination in a food laboratory. In 2012, chocolate bars shipped from Belgium to the USA were prevented from entering the USA because a Salmonella Rissen strain had been isolated from one of the chocolate bars in a Belgian food laboratory. However, a retrospective study of the Salmonella isolates sent from the laboratory to the Belgian National Reference Laboratory for Salmonella revealed that 7 weeks prior, a Salmonella Rissen strain has been isolated from fish meal in the same food laboratory. The chocolate bars were not expected to be contaminated with Salmonella because the ingredients all tested negative during the production process. Furthermore, because Salmonella Rissen is only rarely isolated from food, it was hypothesized that the two Salmonella Rissen isolates belonged to the same strain and that the second isolation event in this laboratory was caused by cross-contamination. To confirm this hypothesis, both Salmonella Rissen isolates were fingerprinted using different molecular techniques. To evaluate the discriminatory power of the techniques used, 11 other Salmonella Rissen isolates from different origins were included in the comparison. Pulsed-field gel electrophoresis, repetitive element palindromic PCR and three random amplified polymorphic DNA PCR assays were used. Repetitive element palindromic PCR and random amplified polymorphic DNA PCR assays were insufficiently discriminatory, whereas pulsed-field gel electrophoresis using the combination of two restriction enzymes showed sufficient discrimination to confirm the hypothesis. Although cross-contamination in food laboratories are rarely reported, cross-contamination can always occur. Laboratories should therefore always be aware of the possibility of cross-contamination, especially when enrichment is used in the microbiological analysis. Furthermore, it is advised that results showing isolates of the same serotype isolated in a short time frame

  10. A Compendium on the NIST Radionuclidic Assays of the Massic Activity of 63Ni and 55Fe Solutions Used for an International Intercomparison of Liquid Scintillation Spectrometry Techniques

    PubMed Central

    Collé, R.; Zimmerman, B. E.

    1997-01-01

    The National Institute of Standards and Technology recently participated in an international measurement intercomparison for 63Ni and 55Fe, which was conducted amongst principal national radionuclidic metrology laboratories. The intercomparison was sponsored by EUROMET, and was primarily intended to evaluate the capabilities of liquid scintillation (LS) spectrometry techniques for standardizing nuclides that decay by low-energy β-emission (like 63Ni) and by low-Z (atomic number) electron capture (like 55Fe). The intercomparison findings exhibit a very good agreement for 63Ni amongst the various participating laboratories, including that for NIST, which suggests that the presently invoked LS methodologies are very capable of providing internationally-compatible standardizations for low-energy β-emitters. The results for 55Fe are in considerably poorer agreement, and demonstrated the existence of several unresolved problems. It has thus become apparent that there is a need for the various international laboratories to conduct rigorous, systematic evaluations of their LS capabilities in assaying radionuclides that decay by low-Z electron capture. PMID:27805141

  11. In situ calibration of a high-resolution gamma-ray borehole sonde for assaying uranium-bearing sandstone deposits

    USGS Publications Warehouse

    Day, J.H.

    1985-01-01

    A method is presented for assaying radioactive sandstone deposits in situ by using a high-resolution borehole gamma-ray spectrometer. Gamma-ray photopeaks from the same spectrum acquired to analyze a sample are used to characterize gamma-ray attenuation properties, from which a calibration function is determined. Assay results are independent of differences between properties of field samples and those of laboratory or test-hole standards generally used to calibrate a borehole sonde. This assaying technique is also independent of the state of radioactive disequilibrium that usually exists in nature among members of the natural-decay chains. ?? 1985.

  12. Demonstrations of Extraterrestrial Life Detection Techniques in the High School Biology Laboratory

    ERIC Educational Resources Information Center

    Saltinski, Ronald

    1969-01-01

    Discusses the experimental procedures and equipment for exobiology projects at the high school level. An interdisciplinary approach involving electronic equipment and micro-biological laboratory techniques is used. Photographs and diagrams of equipment are included. Bibliography. (LC)

  13. Determination of meteor parameters using laboratory simulation techniques

    NASA Technical Reports Server (NTRS)

    Friichtenicht, J. F.; Becker, D. G.

    1973-01-01

    Atmospheric entry of meteoritic bodies is conveniently and accurately simulated in the laboratory by techniques which employ the charging and electrostatic acceleration of macroscopic solid particles. Velocities from below 10 to above 50 km/s are achieved for particle materials which are elemental meteoroid constituents or mineral compounds with characteristics similar to those of meteoritic stone. The velocity, mass, and kinetic energy of each particle are measured nondestructively, after which the particle enters a target gas region. Because of the small particle size, free molecule flow is obtained. At typical operating pressures (0.1 to 0.5 torr), complete particle ablation occurs over distances of 25 to 50 cm; the spatial extent of the atmospheric interaction phenomena is correspondingly small. Procedures have been developed for measuring the spectrum of light from luminous trails and the values of fundamental quantities defined in meteor theory. It is shown that laboratory values for iron are in excellent agreement with those for 9 to 11 km/s artificial meteors produced by rocket injection of iron bodies into the atmosphere.

  14. A Survey of the Practices, Procedures, and Techniques in Undergraduate Organic Chemistry Teaching Laboratories

    ERIC Educational Resources Information Center

    Martin, Christopher B.; Schmidt, Monica; Soniat, Michael

    2011-01-01

    A survey was conducted of four-year institutions that teach undergraduate organic chemistry laboratories in the United States. The data include results from over 130 schools, describes the current practices at these institutions, and discusses the statistical results such as the scale of the laboratories performed, the chemical techniques applied,…

  15. Opportunities for bead-based multiplex assays in veterinary diagnostic laboratories

    USDA-ARS?s Scientific Manuscript database

    Bead based multiplex assays (BBMA) also referred to as Luminex, MultiAnalyte Profiling or cytometric bead array (CBA) assays, are applicable for high throughput, simultaneous detection of multiple analytes in solution (from several, up to 50-500 analytes within a single, small sample volume). Curren...

  16. New developments of X-ray fluorescence imaging techniques in laboratory

    NASA Astrophysics Data System (ADS)

    Tsuji, Kouichi; Matsuno, Tsuyoshi; Takimoto, Yuki; Yamanashi, Masaki; Kometani, Noritsugu; Sasaki, Yuji C.; Hasegawa, Takeshi; Kato, Shuichi; Yamada, Takashi; Shoji, Takashi; Kawahara, Naoki

    2015-11-01

    X-ray fluorescence (XRF) analysis is a well-established analytical technique with a long research history. Many applications have been reported in various fields, such as in the environmental, archeological, biological, and forensic sciences as well as in industry. This is because XRF has a unique advantage of being a nondestructive analytical tool with good precision for quantitative analysis. Recent advances in XRF analysis have been realized by the development of new x-ray optics and x-ray detectors. Advanced x-ray focusing optics enables the making of a micro x-ray beam, leading to micro-XRF analysis and XRF imaging. A confocal micro-XRF technique has been applied for the visualization of elemental distributions inside the samples. This technique was applied for liquid samples and for monitoring chemical reactions such as the metal corrosion of steel samples in the NaCl solutions. In addition, a principal component analysis was applied for reducing the background intensity in XRF spectra obtained during XRF mapping, leading to improved spatial resolution of confocal micro-XRF images. In parallel, the authors have proposed a wavelength dispersive XRF (WD-XRF) imaging spectrometer for a fast elemental imaging. A new two dimensional x-ray detector, the Pilatus detector was applied for WD-XRF imaging. Fast XRF imaging in 1 s or even less was demonstrated for Euro coins and industrial samples. In this review paper, these recent advances in laboratory-based XRF imaging, especially in a laboratory setting, will be introduced.

  17. An European inter-laboratory validation of alternative endpoints of the murine local lymph node assay: 2nd round.

    PubMed

    Ehling, G; Hecht, M; Heusener, A; Huesler, J; Gamer, A O; van Loveren, H; Maurer, Th; Riecke, K; Ullmann, L; Ulrich, P; Vandebriel, R; Vohr, H-W

    2005-08-15

    The original local lymph node assay (LLNA) is based on the use of radioactive labelling to measure cell proliferation. Other endpoints for the assessment of proliferation are also authorized by the OECD Guideline 429 provided there is appropriate scientific support, including full citations and description of the methodology (OECD, 2002. OECD Guideline for the Testing of Chemicals; Skin Sensitization: Local Lymph Node Assay, Guideline 429. Paris, adopted 24th April 2002.). Here, we describe the outcome of the second round of an inter-laboratory validation of alternative endpoints in the LLNA conducted in nine laboratories in Europe. The validation study was managed and supervised by the Swiss Agency for Therapeutic Products (Swissmedic) in Bern. Ear-draining lymph node (LN) weight and cell counts were used to assess LN cell proliferation instead of [3H]TdR incorporation. In addition, the acute inflammatory skin reaction was measured by ear weight determination of circular biopsies of the ears to identify skin irritation properties of the test items. The statistical analysis was performed in the department of statistics at the university of Bern. Similar to the EC(3) values defined for the radioactive method, threshold values were calculated for the endpoints measured in this modification of the LLNA. It was concluded that all parameters measured have to be taken into consideration for the categorisation of compounds due to their sensitising potencies. Therefore, an assessment scheme has been developed which turned out to be of great importance to consistently assess sensitisation versus irritancy based on the data of the different parameters. In contrast to the radioactive method, irritants have been picked up by all the laboratories applying this assessment scheme.

  18. ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION USING THE DOUBLE-BUNDLE TECHNIQUE – EVALUATION IN THE BIOMECHANICS LABORATORY

    PubMed Central

    D'Elia, Caio Oliveira; Bitar, Alexandre Carneiro; Castropil, Wagner; Garofo, Antônio Guilherme Padovani; Cantuária, Anita Lopes; Orselli, Maria Isabel Veras; Luques, Isabela Ugo; Duarte, Marcos

    2015-01-01

    Objective: The objective of this study was to describe the methodology of knee rotation analysis using biomechanics laboratory instruments and to present the preliminary results from a comparative study on patients who underwent anterior cruciate ligament (ACL) reconstruction using the double-bundle technique. Methods: The protocol currently used in our laboratory was described. Three-dimensional kinematic analysis was performed and knee rotation amplitude was measured on eight normal patients (control group) and 12 patients who were operated using the double-bundle technique, by means of three tasks in the biomechanics laboratory. Results: No significant differences between operated and non-operated sides were shown in relation to the mean amplitudes of gait, gait with change in direction or gait with change in direction when going down stairs (p > 0.13). Conclusion: The preliminary results did not show any difference in the double-bundle ACL reconstruction technique in relation to the contralateral side and the control group. PMID:27027003

  19. Radiobacteriolysis: a New Technique Using Chromium-51 for Assaying Anti- Vibrio cholerae Antibodies

    PubMed Central

    Blachman, Uzy; Clark, W. R.; Pickett, M. J.

    1973-01-01

    A new method for detecting and quantitating antibodies against Vibrio cholerae is described. The reaction involves the release of radiochromium from prelabeled vibrios in the presence of specific antibody and complement. The entire assay can be completed within 5 hr. The method is highly reproducible, immunologically specific, temperature- and complement-dependent, and significantly more sensitive than other methods currently used for titration of anti-Vibrio cholerae antibodies. The technique is also potentially applicable to titration of antibodies against other gram-negative bacteria. PMID:4570279

  20. Laboratory Diagnostics of Botulism

    PubMed Central

    Lindström, Miia; Korkeala, Hannu

    2006-01-01

    Botulism is a potentially lethal paralytic disease caused by botulinum neurotoxin. Human pathogenic neurotoxins of types A, B, E, and F are produced by a diverse group of anaerobic spore-forming bacteria, including Clostridium botulinum groups I and II, Clostridium butyricum, and Clostridium baratii. The routine laboratory diagnostics of botulism is based on the detection of botulinum neurotoxin in the patient. Detection of toxin-producing clostridia in the patient and/or the vehicle confirms the diagnosis. The neurotoxin detection is based on the mouse lethality assay. Sensitive and rapid in vitro assays have been developed, but they have not yet been appropriately validated on clinical and food matrices. Culture methods for C. botulinum are poorly developed, and efficient isolation and identification tools are lacking. Molecular techniques targeted to the neurotoxin genes are ideal for the detection and identification of C. botulinum, but they do not detect biologically active neurotoxin and should not be used alone. Apart from rapid diagnosis, the laboratory diagnostics of botulism should aim at increasing our understanding of the epidemiology and prevention of the disease. Therefore, the toxin-producing organisms should be routinely isolated from the patient and the vehicle. The physiological group and genetic traits of the isolates should be determined. PMID:16614251

  1. Multiplex tandem mass spectrometry assay for newborn screening of X-linked adrenoleukodystrophy, biotinidase deficiency, and galactosemia with flexibility to assay other enzyme assays and biomarkers.

    PubMed

    Hong, Xinying; Kumar, Arun Babu; Ronald Scott, C; Gelb, Michael H

    2018-03-29

    All States screen for biotinidase deficiency and galactosemia, and X-linked adrenoleukodystrophy (X-ALD) has recently been added to the Recommended Uniform Screening Panel (RUSP).We sought to consolidate these tests by combining them into a single multiplex tandem mass spectrometry assay as well as to improve the current protocol for newborn screening of galactosemia.A 3 mm punch of a dried blood spot (DBS) was extracted with organic solvent for analysis of the C26:0-lysophosphatidylcholine biomarker for X-ALD.An additional punch was used to assay galactose-1-phosphate uridyltransferase (GALT) and biotinidase.All assays were combined for a single injection for analysis by liquid chromatography-tandem mass spectrometry (LC-MS/MS) (2.3 min per sample).The GALT LC-MS/MS assay does not give a false positive for galactosemia if glucose-6-phosphate dehydrogenase is deficient.The multiplex assay shows acceptable reproducibility and provides for rapid analysis of X-ALD, biotinidase deficiency, and galactosemia.The throughput and ease of sample preparation are acceptable for newborn screening laboratories.We also show that the LC-MS/MS assay is expandable to include several other diseases including Pompe and Hurler diseases (enzymatic activities and biomarkers).Because of consolidation of assays, less manpower is needed compared to running individual assays on separate platforms.The flexibility of the LC-MS/MS platform allows each newborn screening laboratory to analyze the set of diseases offered in their panel. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Evaluation of the Xpert MTB/RIF assay for diagnosis of tuberculosis and rifampin resistance in county-level laboratories in Hunan province, China.

    PubMed

    Hu, Peilei; Bai, Liqiong; Liu, Fengping; Ou, Xichao; Zhang, Zhiying; Yi, Songlin; Chen, Zhongnan; Gong, Daofang; Liu, Binbin; Guo, Jingwei; Tan, Yunhong

    2014-01-01

    The Xpert MTB/RIF showed high sensitivity and specificity in previous studies carried out in different epidemiological and geographical settings and patient populations in high-burden tuberculosis (TB) countries. However, there were little data obtained by validation or demonstration study of the assay in China. In this study, the performance of Xpert MTB/RIF was investigated in two county-level laboratories in Hunan Province, China. Consecutive patients with suspected pulmonary tuberculosis (PTB) and suspicion for multidrug-resistant tuberculosis (MDR-TB) were enrolled. For each patient suspected to have PTB, three sputum specimens (one spot sputum, one night sputum, and one morning sputum) were collected and each sputum was tested with smear microscopy, Löwenstein-Jensen (LJ) culture, and Xpert MTB/RIF test. For comparison across subgroups and testing methods, 95% confidence intervals were calculated. All analyses were done with SPSS 16.0, and P < 0.05 was regarded as significant. For case detection, the sensitivity of Xpert MTB/RIF was 100% for smear- and culture-positive TB and 88.6% for smear-negative and culture-positive TB; the overall sensitivity was 94.5% for all culture-positive patients. The specificity was 99.8%. The sensitivity of Xpert MTB/RIF assay was 22.0% in clinical TB patients and the specificity reached 100.0% in the group of patients who are infected with nontuberculous mycobacteria. For the detection of rifampin resistance, the sensitivity of MTB/RIF RIF-resistance detection was 92.9%, and the specificity was 98.7%. Of the 26 Xpert MTB/RIF-positive and RIF-resistant patients confirmed by LJ proportion tests, 20 (76.9%) patients were infected by MDR-TB. The Xpert MTB/RIF assay is a highly sensitive and specific method for diagnosis of TB and RIF resistance, which will enable it to have the potential to be used in county-level laboratories and lead to the reduction of the infectious pool and improvements in TB control in China. Further

  3. Using the CPTAC Assay Portal to identify and implement highly characterized targeted proteomics assays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whiteaker, Jeffrey R.; Halusa, Goran; Hoofnagle, Andrew N.

    2016-02-12

    The Clinical Proteomic Tumor Analysis Consortium (CPTAC) of the National Cancer Institute (NCI) has launched an Assay Portal (http://assays.cancer.gov) to serve as an open-source repository of well-characterized targeted proteomic assays. The portal is designed to curate and disseminate highly characterized, targeted mass spectrometry (MS)-based assays by providing detailed assay performance characterization data, standard operating procedures, and access to reagents. Assay content is accessed via the portal through queries to find assays targeting proteins associated with specific cellular pathways, protein complexes, or specific chromosomal regions. The position of the peptide analytes for which there are available assays are mapped relative tomore » other features of interest in the protein, such as sequence domains, isoforms, single nucleotide polymorphisms, and post-translational modifications. The overarching goals are to enable robust quantification of all human proteins and to standardize the quantification of targeted MS-based assays to ultimately enable harmonization of results over time and across laboratories.« less

  4. Using the CPTAC Assay Portal to Identify and Implement Highly Characterized Targeted Proteomics Assays.

    PubMed

    Whiteaker, Jeffrey R; Halusa, Goran N; Hoofnagle, Andrew N; Sharma, Vagisha; MacLean, Brendan; Yan, Ping; Wrobel, John A; Kennedy, Jacob; Mani, D R; Zimmerman, Lisa J; Meyer, Matthew R; Mesri, Mehdi; Boja, Emily; Carr, Steven A; Chan, Daniel W; Chen, Xian; Chen, Jing; Davies, Sherri R; Ellis, Matthew J C; Fenyö, David; Hiltke, Tara; Ketchum, Karen A; Kinsinger, Chris; Kuhn, Eric; Liebler, Daniel C; Liu, Tao; Loss, Michael; MacCoss, Michael J; Qian, Wei-Jun; Rivers, Robert; Rodland, Karin D; Ruggles, Kelly V; Scott, Mitchell G; Smith, Richard D; Thomas, Stefani; Townsend, R Reid; Whiteley, Gordon; Wu, Chaochao; Zhang, Hui; Zhang, Zhen; Rodriguez, Henry; Paulovich, Amanda G

    2016-01-01

    The Clinical Proteomic Tumor Analysis Consortium (CPTAC) of the National Cancer Institute (NCI) has launched an Assay Portal (http://assays.cancer.gov) to serve as an open-source repository of well-characterized targeted proteomic assays. The portal is designed to curate and disseminate highly characterized, targeted mass spectrometry (MS)-based assays by providing detailed assay performance characterization data, standard operating procedures, and access to reagents. Assay content is accessed via the portal through queries to find assays targeting proteins associated with specific cellular pathways, protein complexes, or specific chromosomal regions. The position of the peptide analytes for which there are available assays are mapped relative to other features of interest in the protein, such as sequence domains, isoforms, single nucleotide polymorphisms, and posttranslational modifications. The overarching goals are to enable robust quantification of all human proteins and to standardize the quantification of targeted MS-based assays to ultimately enable harmonization of results over time and across laboratories.

  5. ELECTRONICS UPGRADE TO THE SAVANNAH RIVER NATIONAL LABORATORY COULOMETER FOR PLUTONIUM AND NEPTUNIUM ASSAY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cordaro, J.; Holland, M.; Reeves, G.

    The Savannah River Site (SRS) has the analytical measurement capability to perform high-precision plutonium concentration measurements by controlled-potential coulometry. State-of-the-art controlled-potential coulometers were designed and fabricated by the Savannah River National Laboratory and installed in the Analytical Laboratories process control laboratory. The Analytical Laboratories uses coulometry for routine accountability measurements of and for verification of standard preparations used to calibrate other plutonium measurement systems routinely applied to process control, nuclear safety, and other accountability applications. The SRNL Coulometer has a demonstrated measurement reliability of {approx}0.05% for 10 mg samples. The system has also been applied to the characterization of neptuniummore » standard solutions with a comparable reliability. The SRNL coulometer features: a patented current integration system; continuous electrical calibration versus Faraday's Constants and Ohm's Law; the control-potential adjustment technique for enhanced application of the Nernst Equation; a wide operating room temperature range; and a fully automated instrument control and data acquisition capability. Systems have been supplied to the International Atomic Energy Agency (IAEA), Russia, Japanese Atomic Energy Agency (JAEA) and the New Brunswick Laboratory (NBL). The most recent vintage of electronics was based on early 1990's integrated circuits. Many of the components are no longer available. At the request of the IAEA and the Department of State, SRNL has completed an electronics upgrade of their controlled-potential coulometer design. Three systems have built with the new design, one for the IAEA which was installed at SAL in May 2011, one system for Los Alamos National Laboratory, (LANL) and one for the SRS Analytical Laboratory. The LANL and SRS systems are undergoing startup testing with installation scheduled for this summer.« less

  6. Colorimetric micro-assay for accelerated screening of mould inhibitors

    Treesearch

    Carol A. Clausen; Vina W. Yang

    2013-01-01

    Since current standard laboratory methods are time-consuming macro-assays that rely on subjective visual ratings of mould growth, rapid and quantitative laboratory methods are needed to screen potential mould inhibitors for use in and on cellulose-based products. A colorimetric micro-assay has been developed that uses XTT tetrazolium salt to enzymatically assess...

  7. Comparison of Laboratory-Developed and Commercial Monoclonal Antibody-Based Sandwich Enzyme-Linked Immunosorbent Assays for Almond (Prunus dulcis) Detection and Quantification.

    PubMed

    Liu, Changqi; Chhabra, Guneet S; Zhao, Jing; Zaffran, Valerie D; Gupta, Sahil; Roux, Kenneth H; Gradziel, Thomas M; Sathe, Shridhar K

    2017-10-01

    A commercially available monoclonal antibody (mAb)-based direct sandwich enzyme-linked immunosorbent assay (ELISA) kit (BioFront Technologies, Tallahassee, Fla., U.S.A.) was compared with an in-house developed mAb 4C10-based ELISA for almond detection. The assays were comparable in sensitivity (limit of detection < 1 ppm full fat almond, limit of quantification < 5 ppm full fat almond), specificity (no cross-reactivity with 156 tested foods at a concentration of 100000 ppm whole sample), and reproducibility (intra- and interassay variability < 15% CV). The target antigens were stable and detectable in whole almond seeds subjected to autoclaving, blanching, frying, microwaving, and dry roasting. The almond recovery ranges for spiked food matrices were 84.3% to 124.6% for 4C10 ELISA and 81.2% to 127.4% for MonoTrace ELISA. The almond recovery ranges for commercial and laboratory prepared foods with declared/known almond amount were 30.9% to 161.2% for 4C10 ELISA and 38.1% to 207.6% for MonoTrace ELISA. Neither assay registered any false-positive or negative results among the tested commercial and laboratory prepared samples. Ability to detect and quantify trace amounts of almonds is important for improving safety of almond sensitive consumers. Two monoclonal antibody-based ELISAs were compared for almond detection. The information is useful to food industry, regulatory agencies, scientific community, and almond consumers. © 2017 Institute of Food Technologists®.

  8. Application of statistical process control to qualitative molecular diagnostic assays.

    PubMed

    O'Brien, Cathal P; Finn, Stephen P

    2014-01-01

    Modern pathology laboratories and in particular high throughput laboratories such as clinical chemistry have developed a reliable system for statistical process control (SPC). Such a system is absent from the majority of molecular laboratories and where present is confined to quantitative assays. As the inability to apply SPC to an assay is an obvious disadvantage this study aimed to solve this problem by using a frequency estimate coupled with a confidence interval calculation to detect deviations from an expected mutation frequency. The results of this study demonstrate the strengths and weaknesses of this approach and highlight minimum sample number requirements. Notably, assays with low mutation frequencies and detection of small deviations from an expected value require greater sample numbers to mitigate a protracted time to detection. Modeled laboratory data was also used to highlight how this approach might be applied in a routine molecular laboratory. This article is the first to describe the application of SPC to qualitative laboratory data.

  9. Thoracic organ transplantation: laboratory methods.

    PubMed

    Patel, Jignesh K; Kobashigawa, Jon A

    2013-01-01

    Although great progress has been achieved in thoracic organ transplantation through the development of effective immunosuppression, there is still significant risk of rejection during the early post-transplant period, creating a need for routine monitoring for both acute antibody and cellular mediated rejection. The currently available multiplexed, microbead assays utilizing solubilized HLA antigens afford the capability of sensitive detection and identification of HLA and non-HLA specific antibodies. These assays are being used to assess the relative strength of donor specific antibodies; to permit performance of virtual crossmatches which can reduce the waiting time to transplantation; to monitor antibody levels during desensitization; and for heart transplants to monitor antibodies post-transplant. For cell mediated immune responses, the recent development of gene expression profiling has allowed noninvasive monitoring of heart transplant recipients yielding predictive values for acute cellular rejection. T cell immune monitoring in heart and lung transplant recipients has allowed individual tailoring of immunosuppression, particularly to minimize risk of infection. While the current antibody and cellular laboratory techniques have enhanced the ability to manage thoracic organ transplant recipients, future developments from improved understanding of microchimerism and graft tolerance may allow more refined allograft monitoring techniques.

  10. International Technology Transfer of a GCLP-Compliant HIV-1 Neutralizing Antibody Assay for Human Clinical Trials

    PubMed Central

    Todd, Christopher A.; Greene, Kelli M.; Montefiori, David C.; Sarzotti-Kelsoe, Marcella

    2012-01-01

    The Collaboration for AIDS Vaccine Discovery/Comprehensive Antibody – Vaccine Immune Monitoring Consortium (CAVD/CA-VIMC) assisted an international network of laboratories in transferring a validated assay used to judge HIV-1 vaccine immunogenicity in compliance with Good Clinical Laboratory Practice (GCLP) with the goal of adding quality to the conduct of endpoint assays for Human Immunodeficiency Virus I (HIV-1) vaccine human clinical trials. Eight Regional Laboratories in the international setting (Regional Laboratories), many located in regions where the HIV-1 epidemic is most prominent, were selected to implement the standardized, GCLP-compliant Neutralizing Antibody Assay for HIV-1 in TZM-bl Cells (TZM-bl NAb Assay). Each laboratory was required to undergo initial training and implementation of the immunologic assay on-site and then perform partial assay re-validation, competency testing, and undergo formal external audits for GCLP compliance. Furthermore, using a newly established external proficiency testing program for the TZM-bl NAb Assay has allowed the Regional Laboratories to assess the comparability of assay results at their site with the results of neutralizing antibody assays performed around the world. As a result, several of the CAVD/CA-VIMC Regional Laboratories are now in the process of conducting or planning to conduct the GCLP-compliant TZM-bl NAb Assay as an indicator of vaccine immunogenicity for ongoing human clinical trials. PMID:22303476

  11. International technology transfer of a GCLP-compliant HIV-1 neutralizing antibody assay for human clinical trials.

    PubMed

    Ozaki, Daniel A; Gao, Hongmei; Todd, Christopher A; Greene, Kelli M; Montefiori, David C; Sarzotti-Kelsoe, Marcella

    2012-01-01

    The Collaboration for AIDS Vaccine Discovery/Comprehensive Antibody-Vaccine Immune Monitoring Consortium (CAVD/CA-VIMC) assisted an international network of laboratories in transferring a validated assay used to judge HIV-1 vaccine immunogenicity in compliance with Good Clinical Laboratory Practice (GCLP) with the goal of adding quality to the conduct of endpoint assays for Human Immunodeficiency Virus I (HIV-1) vaccine human clinical trials. Eight Regional Laboratories in the international setting (Regional Laboratories), many located in regions where the HIV-1 epidemic is most prominent, were selected to implement the standardized, GCLP-compliant Neutralizing Antibody Assay for HIV-1 in TZM-bl Cells (TZM-bl NAb Assay). Each laboratory was required to undergo initial training and implementation of the immunologic assay on-site and then perform partial assay re-validation, competency testing, and undergo formal external audits for GCLP compliance. Furthermore, using a newly established external proficiency testing program for the TZM-bl NAb Assay has allowed the Regional Laboratories to assess the comparability of assay results at their site with the results of neutralizing antibody assays performed around the world. As a result, several of the CAVD/CA-VIMC Regional Laboratories are now in the process of conducting or planning to conduct the GCLP-compliant TZM-bl NAb Assay as an indicator of vaccine immunogenicity for ongoing human clinical trials.

  12. TECHNIQUES OF TAPE PREPARATION AND DUPLICATION, WITH SUGGESTIONS FOR A LANGUAGE LABORATORY.

    ERIC Educational Resources Information Center

    Kansas State Dept. of Public Instruction, Topeka.

    PART ONE OF THIS BULLETIN PROVIDES HELP IN THE TWO CRITICAL AREAS OF MASTER TAPE PREPARATION AND DUPLICATION. SUPPLEMENTED BY NUMEROUS PHOTOGRAPHS AND DIAGRAMS OF EQUIPMENT AND DUPLICATION TECHNIQUES, THE BULLETIN DESCRIBES MASTER PROGRAM DUPLICATION USING LANGUAGE LABORATORY EQUIPMENT, A PROFESSIONAL MASS DUPLICATOR, A TAPE RECORDER, A RECORD…

  13. An Undergraduate Laboratory Experiment that Utilizes a Glass Fiber Filter Assay to Determine the Steroid Specificity and Equilibrium Binding Properties of Glucocorticoid Receptors.

    ERIC Educational Resources Information Center

    John, Nancy J.; Firestone, Gary L.

    1987-01-01

    Describes two complementary laboratory exercises that use the glass fiber assay to assess receptor specificity and hormone binding affinity in rat liver cytoplasmic extracts. Details the methods, materials and protocol of the experiments. Discusses the basic concepts illustrated and the feasibility of using the experiments at the undergraduate…

  14. Ligand binding assays in the 21st century laboratory: recommendations for characterization and supply of critical reagents.

    PubMed

    O'Hara, Denise M; Theobald, Valerie; Egan, Adrienne Clements; Usansky, Joel; Krishna, Murli; TerWee, Julie; Maia, Mauricio; Spriggs, Frank P; Kenney, John; Safavi, Afshin; Keefe, Jeannine

    2012-06-01

    Critical reagents are essential components of ligand binding assays (LBAs) and are utilized throughout the process of drug discovery, development, and post-marketing monitoring. Successful lifecycle management of LBA critical reagents minimizes assay performance problems caused by declining reagent activity and can mitigate the risk of delays during preclinical and clinical studies. Proactive reagent management assures adequate supply. It also assures that the quality of critical reagents is appropriate and consistent for the intended LBA use throughout all stages of the drug development process. This manuscript summarizes the key considerations for the generation, production, characterization, qualification, documentation, and management of critical reagents in LBAs, with recommendations for antibodies (monoclonal and polyclonal), engineered proteins, peptides, and their conjugates. Recommendations are given for each reagent type on basic and optional characterization profiles, expiration dates and storage temperatures, and investment in a knowledge database system. These recommendations represent a consensus among the authors and should be used to assist bioanalytical laboratories in the implementation of a best practices program for critical reagent life cycle management.

  15. Critical Value Reporting at Egyptian Laboratories.

    PubMed

    Mosallam, Rasha; Ibrahim, Samaa Zenhom

    2015-06-12

    To examine critical value reporting policies and practices and to identify critical value ranges for selected common laboratory assays at inpatient division of laboratories of Alexandria hospitals. A cross-sectional descriptive study design was used. Subjects were from inpatient division of all laboratories of Alexandria hospitals (40 laboratories). Data were collected using a questionnaire composed of 4 sections. The first section explored hospital and laboratory characteristics. The second section assessed policies and procedures of critical value reporting. The third section explored the reporting process. The fourth section explored critical value ranges for selected common laboratory assays. Written procedure for reporting of critical values was present in 77.5% of laboratories and a comprehensive list of critical values in 72.55%. For laboratories having a critical value list, the number of tests in the list ranged from 7 to 40. Three-fifths of laboratories had a policy for assessing the timeliness of reporting and 3 quarters stated that the laboratory policy requires feedback (60.0% and 75.0%, respectively). The hospital laboratory physician was responsible for critical value reporting followed by the laboratory technician (75.0% and 50.0%, respectively). The call is received mainly by nurses and physicians ordering the test (67.5% and 55.0%, respectively) and the channel of reporting is mainly the telephone or through sending test report to the ward (67.5% and 50.0%, respectively). Wireless technologies are used in reporting in only 10.0% of hospitals. The cutoff limits for reporting different assays showed considerable interlaboratory variation. Critical value policies and practices showed interinstitutional variation with deficiencies in some reporting practices. Selection of critical assays for notification and setting the limits of notification exhibited wide variation as well.

  16. Laboratory heterogeneity of the lupus anticoagulant: a multicentre study using different clotting assays on a panel of 78 samples. Hemostasis Committee of the "Société Française de Biologie Clinique".

    PubMed

    1992-05-15

    The laboratory heterogeneity of the lupus anticoagulant (LA) was investigated in a multicentre study using a panel of 78 plasma samples diagnosed as containing a LA. Consecutive samples were collected by 12 participants using various screening tests, and sent to 7 laboratories which performed one or more clotting assays among the following: activated partial thromboplastin time (APTT), dilute Russell viper venom time, kaolin clotting time (KCT), dilute tissue thromboplastin time (dTTI) and a platelet neutralization test. For APTT and dTTI, 10 versions of these tests including standard and mixing procedures were carried out. They varied by reagents, phospholipid concentration or methodology. Cut-off times were determined for each test by comparing the results of the panel to those of a control population. When the data of all clotting assays were pooled, 70 of the 78 selected plasmas were considered to contain LA, 15 of them having a low-titer inhibitor. Sensitivity, defined as the proportion of positive results among LA-containing plasmas, varied from 62 to 100% and was positively related to responsiveness (defined as the mean ratio of clotting time to cut-off time). Laboratory heterogeneity of LA-containing plasma was illustrated by a star symbol plot analysis. Different populations of samples, with LA preferentially recognized by one assay (or group of assays) irrespective of the overall sensitivity of this assay, were identified. Multiple component analysis demonstrated the heterogeneity of low-titer inhibitors, which complicates their recognition in routine laboratory investigation.

  17. Circulating microRNA Biomarkers as Liquid Biopsy for Cancer Patients: Pros and Cons of Current Assays

    PubMed Central

    Ono, Shigeshi; Lam, Stella; Nagahara, Makoto; Hoon, Dave S. B.

    2015-01-01

    An increasing number of studies have focused on circulating microRNAs (cmiRNA) in cancer patients’ blood for their potential as minimally-invasive biomarkers. Studies have reported the utility of assessing specific miRNAs in blood as diagnostic/prognostic biomarkers; however, the methodologies are not validated or standardized across laboratories. Unfortunately, there is often minimum limited overlap in techniques between results reported even in similar type studies on the same cancer. This hampers interpretation and reliability of cmiRNA as potential cancer biomarkers. Blood collection and processing, cmiRNA extractions, quality and quantity control of assays, defined patient population assessment, reproducibility, and reference standards all affect the cmiRNA assay results. To date, there is no reported definitive method to assess cmiRNAs. Therefore, appropriate and reliable methodologies are highly necessary in order for cmiRNAs to be used in regulated clinical diagnostic laboratories. In this review, we summarize the developments made over the past decade towards cmiRNA detection and discuss the pros and cons of the assays. PMID:26512704

  18. Detection of Enterovirus D68 in Canadian Laboratories

    PubMed Central

    Hatchette, Todd F.; Drews, Steven J.; Grudeski, Elsie; Booth, Tim; Martineau, Christine; Dust, Kerry; Garceau, Richard; Gubbay, Jonathan; Karnauchow, Tim; Krajden, Mel; Levett, Paul N.; Mazzulli, Tony; McDonald, Ryan R.; McNabb, Alan; Mubareka, Samira; Needle, Robert; Petrich, Astrid; Richardson, Susan; Rutherford, Candy; Smieja, Marek; Tellier, Raymond; Tipples, Graham

    2015-01-01

    The recent emergence of a severe respiratory disease caused by enterovirus D68 prompted investigation into whether Canadian hospital and provincial laboratories can detect this virus using commercial and laboratory-developed assays. This study demonstrated analytical sensitivity differences between commercial and laboratory-developed assays for the detection of enterovirus D68. PMID:25740765

  19. Comparison of Established and Emerging Biodosimetry Assays

    PubMed Central

    Rothkamm, K.; Beinke, C.; Romm, H.; Badie, C.; Balagurunathan, Y.; Barnard, S.; Bernard, N.; Boulay-Greene, H.; Brengues, M.; De Amicis, A.; De Sanctis, S.; Greither, R.; Herodin, F.; Jones, A.; Kabacik, S.; Knie, T.; Kulka, U.; Lista, F.; Martigne, P.; Missel, A.; Moquet, J.; Oestreicher, U.; Peinnequin, A.; Poyot, T.; Roessler, U.; Scherthan, H.; Terbrueggen, B.; Thierens, H.; Valente, M.; Vral, A.; Zenhausern, F.; Meineke, V.; Braselmann, H.; Abend, M.

    2014-01-01

    Rapid biodosimetry tools are required to assist with triage in the case of a large-scale radiation incident. Here, we aimed to determine the dose-assessment accuracy of the well-established dicentric chromosome assay (DCA) and cytokinesis-block micronucleus assay (CBMN) in comparison to the emerging γ-H2AX foci and gene expression assays for triage mode biodosimetry and radiation injury assessment. Coded blood samples exposed to 10 X-ray doses (240 kVp, 1 Gy/min) of up to 6.4 Gy were sent to participants for dose estimation. Report times were documented for each laboratory and assay. The mean absolute difference (MAD) of estimated doses relative to the true doses was calculated. We also merged doses into binary dose categories of clinical relevance and examined accuracy, sensitivity and specificity of the assays. Dose estimates were reported by the first laboratories within 0.3–0.4 days of receipt of samples for the γ-H2AX and gene expression assays compared to 2.4 and 4 days for the DCA and CBMN assays, respectively. Irrespective of the assay we found a 2.5–4-fold variation of interlaboratory accuracy per assay and lowest MAD values for the DCA assay (0.16 Gy) followed by CBMN (0.34 Gy), gene expression (0.34 Gy) and γ-H2AX (0.45 Gy) foci assay. Binary categories of dose estimates could be discriminated with equal efficiency for all assays, but at doses ≥1.5 Gy a 10% decrease in efficiency was observed for the foci assay, which was still comparable to the CBMN assay. In conclusion, the DCA has been confirmed as the gold standard biodosimetry method, but in situations where speed and throughput are more important than ultimate accuracy, the emerging rapid molecular assays have the potential to become useful triage tools. PMID:23862692

  20. Analytical and clinical evaluation of the Abbott RealTime hepatitis B sequencing assay.

    PubMed

    Huh, Hee Jae; Kim, Ji-Youn; Lee, Myoung-Keun; Lee, Nam Yong; Kim, Jong-Won; Ki, Chang-Seok

    2016-12-01

    Long-term nucleoside analogue (NA) treatment leads to selection for drug-resistant mutations in patients undergoing hepatitis B virus (HBV) therapy. The Abbott RealTime HBV Sequencing assay (Abbott assay; Abbott Molecular Inc., Des Plaines, IL, USA) targets the reverse transcriptase region of the polymerase gene and as such has the ability to detect NA resistance-associated mutations in HBV. We evaluated the analytical performance of the Abbott assay and compared its diagnostic performance to that of a laboratory-developed nested-PCR and sequencing method. The analytical sensitivity of the Abbott assay was determined using a serially-diluted WHO International Standard. To validate the clinical performances of the Abbott assay and the laboratory-developed assay, 89 clinical plasma samples with various levels of HBV DNA were tested using both assays. The limit of detection of the Abbott assay, was 210IU/ml and it successfully detected mutations when the mutant types were present at levels ≥20%. Among 89 clinical specimens, 43 and 42 were amplification positive in the Abbott and laboratory-developed assays, respectively, with 87.6% overall agreement (78/89; 95% confidence interval [CI], 78.6-93.4). The Abbott assay failed to detect the minor mutant populations in two specimens, and therefore overall concordance was 85.3% (76/89), and the kappa value was 0.79 (95% CI, 0.67-0.90). The Abbott assay showed comparable diagnostic performance to laboratory-developed nested PCR followed by direct sequencing, and may be useful as a routine method for detecting HBV NA resistance-associated mutations in clinical laboratory settings. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. When is it time to get married? Or when should the assay user and the assay developer collaborate?

    PubMed Central

    Swan, S H; Lasley, B L

    1991-01-01

    Hormone assays are being developed in the laboratory to detect specific molecular markers in nonclinical populations. Epidemiology is increasingly using these assays to improve the precision with which disease processes and exposures can be defined. This growing body of molecular epidemiology requires a high degree of cooperation between the assay developer and the assay user. We draw on our experience in using a sensitive hormone assay for the detection of early pregnancy via urinary human chorionic gonadotropin to illustrate these points. We conclude that this collaborative effort, in addition to making this study possible, has provided unexpected rewards. PMID:1954925

  2. Analytical and Clinical Performance Evaluation of the Abbott Architect PIVKA Assay.

    PubMed

    Ko, Dae-Hyun; Hyun, Jungwon; Kim, Hyun Soo; Park, Min-Jeong; Kim, Jae-Seok; Park, Ji-Young; Shin, Dong Hoon; Cho, Hyoun Chan

    2018-01-01

    Protein induced by vitamin K absence (PIVKA) is measured using various assays and is used to help diagnose hepatocellular carcinoma. The present study evaluated the analytical and clinical performances of the recently released Abbott Architect PIVKA assay. Precision, linearity, and correlation tests were performed in accordance with the Clinical Laboratory Standardization Institute guidelines. Sample type suitability was assessed using serum and plasma samples from the same patients, and the reference interval was established using sera from 204 healthy individuals. The assay had coefficients of variation of 3.2-3.5% and intra-laboratory variation of 3.6-5.5%. Linearity was confirmed across the entire measurable range. The Architect PIVKA assay was comparable to the Lumipulse PIVKA assay, and the plasma and serum samples provided similar results. The lower reference limit was 13.0 mAU/mL and the upper reference limit was 37.4 mAU/mL. The ability of the Architect PIVKA assay to detect hepatocellular carcinoma was comparable to that of the alpha-fetoprotein test and the Lumipulse PIVKA assay. The Architect PIVKA assay provides excellent analytical and clinical performance, is simple for clinical laboratories to adopt, and has improved sample type suitability that could broaden the assay's utility. © 2018 by the Association of Clinical Scientists, Inc.

  3. Scoping study to expedite development of a field deployable and portable instrument for UF6 enrichment assay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chan, George; Valentine, John D.; Russo, Richard E.

    The primary objective of the present study is to identity the most promising, viable technologies that are likely to culminate in an expedited development of the next-generation, field-deployable instrument for providing rapid, accurate, and precise enrichment assay of uranium hexafluoride (UF6). UF6 is typically involved, and is arguably the most important uranium compound, in uranium enrichment processes. As the first line of defense against proliferation, accurate analytical techniques to determine the uranium isotopic distribution in UF6 are critical for materials verification, accounting, and safeguards at enrichment plants. As nuclear fuel cycle technology becomes more prevalent around the world, international nuclearmore » safeguards and interest in UF6 enrichment assay has been growing. At present, laboratory-based mass spectrometry (MS), which offers the highest attainable analytical accuracy and precision, is the technique of choice for the analysis of stable and long-lived isotopes. Currently, the International Atomic Energy Agency (IAEA) monitors the production of enriched UF6 at declared facilities by collecting a small amount (between 1 to 10 g) of gaseous UF6 into a sample bottle, which is then shipped under chain of custody to a central laboratory (IAEA’s Nuclear Materials Analysis Laboratory) for high-precision isotopic assay by MS. The logistics are cumbersome and new shipping regulations are making it more difficult to transport UF6. Furthermore, the analysis is costly, and results are not available for some time after sample collection. Hence, the IAEA is challenged to develop effective safeguards approaches at enrichment plants. In-field isotopic analysis of UF6 has the potential to substantially reduce the time, logistics and expense of sample handling. However, current laboratory-based MS techniques require too much infrastructure and operator expertise for field deployment and operation. As outlined in the IAEA Department of Safeguards

  4. Using "Pseudomonas Putida xylE" Gene to Teach Molecular Cloning Techniques for Undergraduates

    ERIC Educational Resources Information Center

    Dong, Xu; Xin, Yi; Ye, Li; Ma, Yufang

    2009-01-01

    We have developed and implemented a serial experiment in molecular cloning laboratory course for undergraduate students majored in biotechnology. "Pseudomonas putida xylE" gene, encoding catechol 2, 3-dioxygenase, was manipulated to learn molecular biology techniques. The integration of cloning, expression, and enzyme assay gave students…

  5. Detection of HLA Antibodies in Organ Transplant Recipients – Triumphs and Challenges of the Solid Phase Bead Assay

    PubMed Central

    Tait, Brian D.

    2016-01-01

    This review outlines the development of human leukocyte antigen (HLA) antibody detection assays and their use in organ transplantation in both antibody screening and crossmatching. The development of sensitive solid phase assays such as the enzyme-linked immunosorbent assay technique, and in particular the bead-based technology has revolutionized this field over the last 10–15 years. This revolution however has created a new paradigm in clinical decision making with respect to the detection of low level pretransplant HLA sensitization and its clinical relevance. The relative sensitivities of the assays used are discussed and the relevance of conflicting inter-assay results. Each assay has its advantages and disadvantages and these are discussed. Over the last decade, the bead-based assay utilizing the Luminex® fluorocytometer instrument has become established as the “gold standard” for HLA antibody testing. However, there are still unresolved issues surrounding this technique, such as the presence of denatured HLA molecules on the beads which reveal cryptic epitopes and the issue of appropriate fluorescence cut off values for positivity. The assay has been modified to detect complement binding (CB) in addition to non-complement binding (NCB) HLA antibodies although the clinical relevance of the CB and NCB IgG isotypes is not fully resolved. The increase sensitivity of the Luminex® bead assay over the complement-dependent cytotoxicity crossmatch has permitted the concept of the “virtual crossmatch” whereby the crossmatch is predicted to a high degree of accuracy based on the HLA antibody specificities detected by the solid phase assay. Dialog between clinicians and laboratory staff on an individual patient basis is essential for correct clinical decision making based on HLA antibody results obtained by the various techniques. PMID:28018342

  6. A Spectrophotometric Assay Optimizing Conditions for Pepsin Activity.

    ERIC Educational Resources Information Center

    Harding, Ethelynda E.; Kimsey, R. Scott

    1998-01-01

    Describes a laboratory protocol optimizing the conditions for the assay of pepsin activity using the Coomasie Blue dye binding assay of protein concentration. The dye bonds through strong, noncovalent interactions to basic and aromatic amino acid residues. (DDR)

  7. Factor VII assay performance: an analysis of the North American Specialized Coagulation Laboratory Association proficiency testing results.

    PubMed

    Zantek, N D; Hsu, P; Refaai, M A; Ledford-Kraemer, M; Meijer, P; Van Cott, E M

    2013-06-01

    The performance of factor VII (FVII) assays currently used by clinical laboratories was examined in North American Specialized Coagulation Laboratory Association (NASCOLA) proficiency tests. Data from 12 surveys conducted between 2008 and 2010, involving 20 unique specimens plus four repeat-tested specimens, were analyzed. The number of laboratories per survey was 49-54 with a total of 1224 responses. Numerous reagent/instrument combinations were used. For FVII > 80 or <40 U/dL, 99.5% of results (859/863) were correctly classified by laboratories as normal/abnormal. Classification of specimens with 40-73 U/dL FVII was heterogeneous. Interlaboratory precision was better for normal specimens (coefficient of variation (CV) 10.7%) than for FVII<20 U/dL (CV 33.1%), with a mean CV of 17.2% per specimen. Intralaboratory precision for repeated specimens demonstrated no significant difference between the paired survey results (mean absolute difference 2.5-5.0 U/dL). For specimens with FVII >50 U/dL, among commonly used methods, one thromboplastin and one calibrator produced results 5-6 U/dL higher and another thromboplastin and calibrator produced results 5-6 U/dL lower than all other methods, and human thromboplastin differed from rabbit by +7.6 U/dL. Preliminary evidence suggests these differences could be due to the calibrator. For FVII <50 U/dL, differences among the commonly used reagents and calibrators were generally not significant. © 2013 Blackwell Publishing Ltd.

  8. Detection of enterovirus D68 in Canadian laboratories.

    PubMed

    Hatchette, Todd F; Drews, Steven J; Grudeski, Elsie; Booth, Tim; Martineau, Christine; Dust, Kerry; Garceau, Richard; Gubbay, Jonathan; Karnauchow, Tim; Krajden, Mel; Levett, Paul N; Mazzulli, Tony; McDonald, Ryan R; McNabb, Alan; Mubareka, Samira; Needle, Robert; Petrich, Astrid; Richardson, Susan; Rutherford, Candy; Smieja, Marek; Tellier, Raymond; Tipples, Graham; LeBlanc, Jason J

    2015-05-01

    The recent emergence of a severe respiratory disease caused by enterovirus D68 prompted investigation into whether Canadian hospital and provincial laboratories can detect this virus using commercial and laboratory-developed assays. This study demonstrated analytical sensitivity differences between commercial and laboratory-developed assays for the detection of enterovirus D68. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  9. Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 2. General Practices.

    PubMed

    Mazur, Steven; Holbrook, Michael R; Burdette, Tracey; Joselyn, Nicole; Barr, Jason; Pusl, Daniela; Bollinger, Laura; Coe, Linda; Jahrling, Peter B; Lackemeyer, Matthew G; Wada, Jiro; Kuhn, Jens H; Janosko, Krisztina

    2016-10-03

    Work in a biosafety level 4 (BSL-4) containment laboratory requires time and great attention to detail. The same work that is done in a BSL-2 laboratory with non-high-consequence pathogens will take significantly longer in a BSL-4 setting. This increased time requirement is due to a multitude of factors that are aimed at protecting the researcher from laboratory-acquired infections, the work environment from potential contamination and the local community from possible release of high-consequence pathogens. Inside the laboratory, movement is restricted due to air hoses attached to the mandatory full-body safety suits. In addition, disinfection of every item that is removed from Class II biosafety cabinets (BSCs) is required. Laboratory specialists must be trained in the practices of the BSL-4 laboratory and must show high proficiency in the skills they are performing. The focus of this article is to outline proper procedures and techniques to ensure laboratory biosafety and experimental accuracy using a standard viral plaque assay as an example procedure. In particular, proper techniques to work safely in a BSL-4 environment when performing an experiment will be visually emphasized. These techniques include: setting up a Class II BSC for experiments, proper cleaning of the Class II BSC when finished working, waste management and safe disposal of waste generated inside a BSL-4 laboratory, and the removal of inactivated samples from inside a BSL-4 laboratory to the BSL-2 laboratory.

  10. PROJECT SUCCESS: Marine Science. (Introductory Packet, Basic Marine Science Laboratory Techniques, Oceanographic Instruments, Individual Projects, Bibliography).

    ERIC Educational Resources Information Center

    Demaray, Bryan

    Five packets comprise the marine science component of an enrichment program for gifted elementary students. Considered in the introductory section are identification (pre/post measure) procedures. Remaining packets address the following topics (subtopics in parentheses): basic marine science laboratory techniques (microscope techniques and metric…

  11. Local lymph node assay: how testing laboratories apply OECD TG 429 for REACH purposes.

    PubMed

    Rovida, Costanza

    2011-01-01

    The Local Lymph Node Assay (LLNA) is the official method for assessing the allergic contact dermatitis potential of chemicals for the purposes of REACH regulation. The LLNA went through a validation process that allowed the delineation of a robust protocol for performing new tests. The OECD accepted this method in 2002 and published OECD TG 429. The European Chemical Agency (ECHA) recently published data that were submitted in the registration dossiers of chemicals. This database was analysed to determine how testing laboratories apply OECD TG 429. This analysis comes after a detailed analysis of four full study reports that were also prepared for REACH purposes. Although the majority of the tests are fully compliant with OECD TG 429, some showed major deviations, and a number of others used more animals than necessary. This suggests that in vivo tests need to be planned more carefully and consciously to obtain meaningful results with the minimum animal number necessary.

  12. Serotype determination of Salmonella by xTAG assay.

    PubMed

    Zheng, Zhibei; Zheng, Wei; Wang, Haoqiu; Pan, Jincao; Pu, Xiaoying

    2017-10-01

    Currently, no protocols or commercial kits are available to determine the serotypes of Salmonella by using Luminex MAGPIX®. In this study, an xTAG assay for serotype determination of Salmonella suitable for Luminex MAGPIX® is described and 228 Salmonella isolates were serotype determined by this xTAG assay. The xTAG assay consists of two steps: 1) Multiplex PCR to amplify simultaneously O, H and Vi antigen genes of Salmonella, and 2) Magplex-TAG™ microsphere hybridization to identify accurately the specific PCR products of different antigens. Compared with the serotyping results of traditional serum agglutination test, the sensitivity and specificity of the xTAG assay were 95.1% and 100%, respectively. The agreement rate of these two assays was 95.2%. Compared with Luminex xMAP® Salmonella Serotyping Assay (SSA) kit, the advantages of this xTAG assay are: First, the magnetic beads make it applicable to both the Luminex®100/200™ and MAGPIX® systems. Second, only primers rather than both primers and probes are needed in the xTAG assay, and the process of coupling antigen-specific oligonucleotide probes to beads is circumvented, which make the xTAG assay convenient to be utilized by other laboratories. The xTAG assay may serve as a rapid alternative or complementary method for traditional Salmonella serotyping tests, especially for laboratories that utilize the MAGPIX® systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. World Health Organization International Standard to harmonize assays for detection of hepatitis E virus RNA.

    PubMed

    Baylis, Sally A; Blümel, Johannes; Mizusawa, Saeko; Matsubayashi, Keiji; Sakata, Hidekatsu; Okada, Yoshiaki; Nübling, C Micha; Hanschmann, Kay-Martin O

    2013-05-01

    Nucleic acid amplification technique-based assays are a primary method for the detection of acute hepatitis E virus (HEV) infection, but assay sensitivity can vary widely. To improve interlaboratory results for the detection and quantification of HEV RNA, a candidate World Health Organization (WHO) International Standard (IS) strain was evaluated in a collaborative study involving 23 laboratories from 10 countries. The IS, code number 6329/10, was formulated by using a genotype 3a HEV strain from a blood donation, diluted in pooled human plasma and lyophilized. A Japanese national standard, representing a genotype 3b HEV strain, was prepared and evaluated in parallel. The potencies of the standards were determined by qualitative and quantitative assays. Assay variability was substantially reduced when HEV RNA concentrations were expressed relative to the IS. Thus, WHO has established 6329/10 as the IS for HEV RNA, with a unitage of 250,000 International Units per milliliter.

  14. A sensitive branched DNA HIV-1 signal amplification viral load assay with single day turnaround.

    PubMed

    Baumeister, Mark A; Zhang, Nan; Beas, Hilda; Brooks, Jesse R; Canchola, Jesse A; Cosenza, Carlo; Kleshik, Felix; Rampersad, Vinod; Surtihadi, Johan; Battersby, Thomas R

    2012-01-01

    Branched DNA (bDNA) is a signal amplification technology used in clinical and research laboratories to quantitatively detect nucleic acids. An overnight incubation is a significant drawback of highly sensitive bDNA assays. The VERSANT® HIV-1 RNA 3.0 Assay (bDNA) ("Versant Assay") currently used in clinical laboratories was modified to allow shorter target incubation, enabling the viral load assay to be run in a single day. To dramatically reduce the target incubation from 16-18 h to 2.5 h, composition of only the "Lysis Diluent" solution was modified. Nucleic acid probes in the assay were unchanged. Performance of the modified assay (assay in development; not commercially available) was evaluated and compared to the Versant Assay. Dilution series replicates (>950 results) were used to demonstrate that analytical sensitivity, linearity, accuracy, and precision for the shorter modified assay are comparable to the Versant Assay. HIV RNA-positive clinical specimens (n = 135) showed no significant difference in quantification between the modified assay and the Versant Assay. Equivalent relative quantification of samples of eight genotypes was demonstrated for the two assays. Elevated levels of several potentially interfering endogenous substances had no effect on quantification or specificity of the modified assay. The modified assay with drastically improved turnaround time demonstrates the viability of signal-amplifying technology, such as bDNA, as an alternative to the PCR-based assays dominating viral load monitoring in clinical laboratories. Highly sensitive bDNA assays with a single day turnaround may be ideal for laboratories with especially stringent cost, contamination, or reliability requirements.

  15. Simple and Rapid System for Two-Dimensional Gel Electrophoresis Technique: A Laboratory Exercise for High School Students

    ERIC Educational Resources Information Center

    Maurye, Praveen; Basu, Arpita; Biswas, Jayanta Kumar; Bandyopadhyay, Tapas Kumar; Naskar, Malay

    2018-01-01

    Polyacrylamide gel electrophoresis (PAGE) is the most classical technique favored worldwide for resolution of macromolecules in many biochemistry laboratories due to its incessant advanced developments and wide modifications. These ever-growing advancements in the basic laboratory equipments lead to emergence of many expensive, complex, and tricky…

  16. Problems with GH assays and strategies toward standardization.

    PubMed

    Bidlingmaier, Martin

    2008-12-01

    Disorders affecting GH secretion--either GH deficiency or GH excess (acromegaly)--are biochemically defined through peak or nadir concentrations of human GH in response to dynamic tests. Immunoassays employing polyclonal or monoclonal antibodies are routinely used for the analysis of GH concentrations, and many different assays are available on the market today. Unfortunately, the actual value reported for the GH concentration in a specific patient's sample to a large extent depends on the assay method used by the respective laboratory. Variability between assay results exceeds 200%, limiting the applicability of consensus guidelines in clinical practice. Reasons for the heterogeneity in GH assay results include the heterogeneity of the analyte itself, the availability of different preparations for calibration, and the interference from matrix components such as GH-binding protein. Furthermore, the reporting of results in mass units or international units together with the application of variable conversion factors led to confusion. International collaborations proposed measures to improve the comparability of assay results, recommending the use of a single, recombinant calibrator for all assays and reporting only in mass units as first steps. However, because of the differences in epitope specificity of antibodies used in different assays, method-specific cut-off levels for dynamic tests might remain necessary to correctly interpret and compare results from different laboratories.

  17. A Sensitive Branched DNA HIV-1 Signal Amplification Viral Load Assay with Single Day Turnaround

    PubMed Central

    Baumeister, Mark A.; Zhang, Nan; Beas, Hilda; Brooks, Jesse R.; Canchola, Jesse A.; Cosenza, Carlo; Kleshik, Felix; Rampersad, Vinod; Surtihadi, Johan; Battersby, Thomas R.

    2012-01-01

    Branched DNA (bDNA) is a signal amplification technology used in clinical and research laboratories to quantitatively detect nucleic acids. An overnight incubation is a significant drawback of highly sensitive bDNA assays. The VERSANT® HIV-1 RNA 3.0 Assay (bDNA) (“Versant Assay”) currently used in clinical laboratories was modified to allow shorter target incubation, enabling the viral load assay to be run in a single day. To dramatically reduce the target incubation from 16–18 h to 2.5 h, composition of only the “Lysis Diluent” solution was modified. Nucleic acid probes in the assay were unchanged. Performance of the modified assay (assay in development; not commercially available) was evaluated and compared to the Versant Assay. Dilution series replicates (>950 results) were used to demonstrate that analytical sensitivity, linearity, accuracy, and precision for the shorter modified assay are comparable to the Versant Assay. HIV RNA-positive clinical specimens (n = 135) showed no significant difference in quantification between the modified assay and the Versant Assay. Equivalent relative quantification of samples of eight genotypes was demonstrated for the two assays. Elevated levels of several potentially interfering endogenous substances had no effect on quantification or specificity of the modified assay. The modified assay with drastically improved turnaround time demonstrates the viability of signal-amplifying technology, such as bDNA, as an alternative to the PCR-based assays dominating viral load monitoring in clinical laboratories. Highly sensitive bDNA assays with a single day turnaround may be ideal for laboratories with especially stringent cost, contamination, or reliability requirements. PMID:22479381

  18. Evaluating 6 ricin field detection assays.

    PubMed

    Slotved, Hans-Christian; Sparding, Nadja; Tanassi, Julia Tanas; Steenhard, Nina R; Heegaard, Niels H H

    2014-01-01

    This study presents data showing the performance of 6 commercial detection assays against ricin around concentrations specified as detection limits by the producers. A 2-fold dilution series of 20 ng/ml ricin was prepared and used for testing the lateral-flow kits: BADD, Pro Strips™, ENVI, RAID DX, Ricin BioThreat Alert, and IMASS™ device. Three of the 6 tested field assays (IMASS™ device, ENVI assay, and the BioThreat Alert assay) were able to detect ricin, although differences in the measured detection limits compared to the official detection limits and false-negative results were observed. We were not able to get the BADD, Pro Strips™, and RAID assays to function in our laboratory. We conclude that when purchasing a field responder assay, there is large variation in the specificity of the assays, and a number of in-house tests must be performed to ensure functionality.

  19. Comparison of five parasitological techniques for laboratory diagnosis of Balantidium coli cysts.

    PubMed

    Barbosa, Alynne da Silva; Bastos, Otilio Machado Pereira; Uchôa, Claudia Maria Antunes; Pissinatti, Alcides; Bastos, Augusto César Machado Pereira; Souza, Igo Vieira de; Dib, Laís Verdan; Azevedo, Eduarda Peixoto; Siqueira, Mayara Perlingeiro de; Cardozo, Matheus Lessa; Amendoeira, Maria Regina Reis

    2016-01-01

    Balantidium coli is a protozoon that can cause dysentery in humans, pigs and nonhuman primates, with zoonotic potential. In the literature, there is still little information on the effectiveness of different laboratory techniques for diagnosing this disease. This study compared and evaluated the performance of the Lutz, modified Ritchie, Faust, modified Sheather and direct examination techniques for detecting cysts of this protozoon. Between 2012 and 2014, 1905 fecal samples were collected from captive animals in the state of Rio de Janeiro. Of these, 790 were obtained from the rectum of pigs and 1115 from enclosures occupied by nonhuman primates. B. coli cysts were most evident through direct examination (22.4% of the samples) and the Lutz technique (21%). Fair agreement (Kappa = 0.41; p < 0.05) was observed only between direct examination and Lutz. The flotation techniques (Faust and modified Sheather) did not show good recovery of cysts. A statistically significant difference (p < 0.05) in the frequency of cysts between pigs and nonhuman primates could only be observed through direct examination and the Lutz technique. The most efficient method for diagnosing this parasitosis was seen to an association between direct examination and the spontaneous sedimentation technique.

  20. Modeling error in experimental assays using the bootstrap principle: Understanding discrepancies between assays using different dispensing technologies

    PubMed Central

    Hanson, Sonya M.; Ekins, Sean; Chodera, John D.

    2015-01-01

    All experimental assay data contains error, but the magnitude, type, and primary origin of this error is often not obvious. Here, we describe a simple set of assay modeling techniques based on the bootstrap principle that allow sources of error and bias to be simulated and propagated into assay results. We demonstrate how deceptively simple operations—such as the creation of a dilution series with a robotic liquid handler—can significantly amplify imprecision and even contribute substantially to bias. To illustrate these techniques, we review an example of how the choice of dispensing technology can impact assay measurements, and show how large contributions to discrepancies between assays can be easily understood and potentially corrected for. These simple modeling techniques—illustrated with an accompanying IPython notebook—can allow modelers to understand the expected error and bias in experimental datasets, and even help experimentalists design assays to more effectively reach accuracy and imprecision goals. PMID:26678597

  1. Loop-mediated isothermal amplification (LAMP) assays for the species-specific detection of Eimeria that infect chickens

    PubMed Central

    2011-01-01

    Background Eimeria parasites can cause the disease coccidiosis in poultry and even subclinical infection can incur economic loss. Diagnosis of infection predominantly relies on traditional techniques including lesion scoring and faecal microscopy despite the availability of sensitive molecular assays, largely due to cost and the requirement for specialist equipment. Despite longstanding proven efficacy these traditional techniques demand time and expertise, can be highly subjective and may under-diagnose subclinical disease. Recognition of the tight economic margins prevailing in modern poultry production and the impact of avian coccidiosis on poverty in many parts of the world has highlighted a requirement for a panel of straightforward and sensitive, but cost-effective, Eimeria species-specific diagnostic assays. Results Loop-mediated isothermal amplification (LAMP) is an uncomplicated, quick and relatively inexpensive diagnostic tool. In this study we have developed a panel of species-specific LAMP assays targeting the seven Eimeria species that infect the chicken. Each assay has been shown to be genuinely species-specific with the capacity to detect between one and ten eimerian genomes, equivalent to less than a single mature schizont. Development of a simple protocol for template DNA preparation from tissue collected post mortem with no requirement for specialist laboratory equipment supports the use of these assays in routine diagnosis of eimerian infection. Preliminary field testing supports this hypothesis. Conclusions Development of a panel of sensitive species-specific LAMP assays introduces a valuable new cost-effective tool for use in poultry husbandry. PMID:22053893

  2. Beyond radio-displacement techniques for Identification of CB1 Ligands: The First Application of a Fluorescence-quenching Assay

    PubMed Central

    Bruno, Agostino; Lembo, Francesca; Novellino, Ettore; Stornaiuolo, Mariano; Marinelli, Luciana

    2014-01-01

    Cannabinoid type 1 Receptor (CB1) belongs to the GPCR family and it has been targeted, so far, for the discovery of drugs aimed at the treatment of neuropathic pain, nausea, vomit, and food intake disorders. Here, we present the development of the first fluorescent assay enabling the measurement of kinetic binding constants for CB1orthosteric ligands. The assay is based on the use of T1117, a fluorescent analogue of AM251. We prove that T1117 binds endogenous and recombinant CB1 receptors with nanomolar affinity. Moreover, T1117 binding to CB1 is sensitive to the allosteric ligand ORG27569 and thus it is applicable to the discovery of new allosteric drugs. The herein presented assay constitutes a sustainable valid alternative to the expensive and environmental impacting radiodisplacement techniques and paves the way for an easy, fast and cheap high-throughput drug screening toward CB1 for identification of new orthosteric and allosteric modulators. PMID:24441508

  3. Integrated Summary Report: Validation of Two Binding Assays ...

    EPA Pesticide Factsheets

    This Integrated Summary Report (ISR) summarizes, in a single document, the results from an international multi-laboratory validation study conducted for two in vitro estrogen receptor (ER) binding assays. These assays both use human recombinant estrogen receptor, alpha subtype (hrERα), to identify chemicals that may impact estrogen signaling through binding to the ER. The purpose of the ISR is to support the peer review of the findings obtained during the validation process.The two assays evaluated during this validation process are: The Freyberger-Wilson Assay (FW) using a full length human ER, and The Chemical Evaluation and Research Institute (CERI) Assay using a ligand-binding domain of the human ER.The two assays are mechanistically and functionally similar in that each measures the ability of a test chemical to competitively inhibit binding of [3H]17β-estradiol to the human recombinant ER. The essential elements of the FW and the CERI assays were developed at the laboratories of Bayer Pharma AG, Wuppertal, Germany (Freyberger et al., 2010) and CERI, Tokyo, Japan (Akahori et al., 2008), respectively.The ER competitive binding assay has long been in use, and is a well characterized approach, but historically uses rodent or other animal tissues as a source of the ER. Validation of the FW and CERI assays using human recombinant estrogen receptors ( subtype) will provide an updated alternative for the Agency’s current test guideline (OPPTS 89

  4. Mussel micronucleus cytome assay.

    PubMed

    Bolognesi, Claudia; Fenech, Michael

    2012-05-17

    The micronucleus (MN) assay is one of the most widely used genotoxicity biomarkers in aquatic organisms, providing an efficient measure of chromosomal DNA damage occurring as a result of either chromosome breakage or chromosome mis-segregation during mitosis. The MN assay is today applied in laboratory and field studies using hemocytes and gill cells from bivalves, mainly from the genera Mytilus. These represent 'sentinel' organisms because of their ability to survive under polluted conditions and to accumulate both organic and inorganic pollutants. Because the mussel MN assay also includes scoring of different cell types, including necrotic and apoptotic cells and other nuclear anomalies, it is in effect an MN cytome assay. The mussel MN cytome (MUMNcyt) assay protocol we describe here reports the recommended experimental design, sample size, cell preparation, cell fixation and staining methods. The protocol also includes criteria and photomicrographs for identifying different cell types and scoring criteria for micronuclei (MNi) and nuclear buds. The complete procedure requires approximately 10 h for each experimental point/sampling station (ten animals).

  5. Premarket evaluations of the IMDx C. difficile for Abbott m2000 Assay and the BD Max Cdiff Assay.

    PubMed

    Stellrecht, K A; Espino, A A; Maceira, V P; Nattanmai, S M; Butt, S A; Wroblewski, D; Hannett, G E; Musser, K A

    2014-05-01

    Clostridium difficile-associated diarrhea is a well-recognized complication of antibiotic use. Historically, diagnosing C. difficile has been difficult, as antigen assays are insensitive and culture-based methods require several days to yield results. Nucleic acid amplification tests (NAATs) are quickly becoming the standard of care. We compared the performance of two automated investigational/research use only (IUO/RUO) NAATs for the detection of C. difficile toxin genes, the IMDx C. difficile for Abbott m2000 Assay (IMDx) and the BD Max Cdiff Assay (Max). A prospective analysis of 111 stool specimens received in the laboratory for C. difficile testing by the laboratory's test of record (TOR), the BD GeneOhm Cdiff Assay, and a retrospective analysis of 88 specimens previously determined to be positive for C. difficile were included in the study. One prospective specimen was excluded due to loss to follow-up discrepancy analysis. Of the remaining 198 specimens, 90 were positive by all three methods, 9 were positive by TOR and Max, and 3 were positive by TOR only. One negative specimen was initially inhibitory by Max. The remaining 95 specimens were negative by all methods. Toxigenic C. difficile culture was performed on the 12 discrepant samples. True C. difficile-positive status was defined as either positive by all three amplification assays or positive by toxigenic culture. Based on this definition, the sensitivity and specificity were 96.9% and 95% for Max and 92.8% and 100% for IMDx. In summary, both highly automated systems demonstrated excellent performance, and each has individual benefits, which will ensure that they will both have a niche in clinical laboratories.

  6. Evaluation of commercial enzyme-linked immunosorbent assays to identify psychedelic phenethylamines.

    PubMed

    Kerrigan, Sarah; Mellon, Monica Brady; Banuelos, Stephanie; Arndt, Crystal

    2011-09-01

    The 2C, 2C-T, and DO series of designer drugs pose a number of challenges to forensic toxicology laboratories. Although these drugs are seized by law enforcement agencies throughout the United States, they are not readily detected in forensic toxicology laboratories. A systematic evaluation of the cross-reactivity of 9 commercial enzyme-linked immunosorbent assays (ELISAs) was conducted using 11 designer drugs. Cross-reactivity was measured towards 2,5-dimethoxy-4-bromophenethylamine (2C-B), 2,5-dimethoxyphenethylamine (2C-H), 2,5-dimethoxy4-iodophenethylamine (2C-I), 2,5-dimethoxy-4ethylthiophenethylamine (2C-T-2), 2,5-dimethoxy-4isopropylthiophenethylamine (2C-T-4), 2,5-dimethoxy-4propylthiophenethylamine (2C-T-7), 2,5-dimethoxy-4bromoamphetamine (DOB), 2,5-dimethoxy-4-ethylamphetamine (DOET), 2,5-dimethoxy-4-iodoamphetamine (DOI), 2,5-dimethoxy-4-methylamphetamine (DOM), and 4methylthioamphetamine (4-MTA). Cross-reactivity towards the 2C, 2C-T, and DO series of psychedelic amphetamines was < 0.4%. Concentrations as high as 50,000 ng/mL in urine, which greatly exceed those expected in forensic case samples, were not sufficient to produce a positive result. The only substance to produce any measurable cross-reactivity was 4-MTA. Cross-reactivities of 5 and 7% were obtained using four methamphetamine/MDMA directed assays, 25 and 200% using two amphetamine-directed assays. The absence of any measurable cross-reactivity towards the 10 2C, 2C-T, and DO psychedelic phenethylamines makes it harder to detect these drugs using routine screening. As a consequence, laboratories that rely upon immunoassay rather than more broad spectrum chromatographic screening techniques, may fail to detect these powerful psychedelic substances.

  7. Development and inter-laboratory transfer of a decaplex polymerase chain reaction assay combined with capillary electrophoresis for the simultaneous detection of ten food allergens.

    PubMed

    Cheng, Fang; Wu, Jiajie; Zhang, Jin; Pan, Aihu; Quan, Sheng; Zhang, Dabing; Kim, HaeYeong; Li, Xiang; Zhou, Shan; Yang, Litao

    2016-05-15

    Food allergies cause health risks to susceptible consumers and regulations on labeling of food allergen contents have been implemented in many countries and regions. To achieve timely and accurate food allergen labeling, the development of fast and effective allergen detection methods is very important. Herein, a decaplex polymerase chain reaction (PCR) assay combined with capillary electrophoresis was developed to detect simultaneously 10 common food allergens from hazelnut, pistachio, oat, sesame, peanut, cashew, barley, wheat, soybean and pecan. The absolute limit of detection (LODa) of this system is between 2 and 20 copies of haploid genome, and the relative LOD (LODr) is as low as 0.005% (w/w) in simulated food mixtures. The developed assay was subsequently applied to 20 commercial food products and verified the allergen ingredients stated on the labels. Furthermore, results using this decaplex PCR assay was successfully replicated in three other laboratories, demonstrating the repeatability and applicability of this assay in routine analysis of the 10 food allergens. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Rapid identification of drug-type strains in Cannabis sativa using loop-mediated isothermal amplification assay.

    PubMed

    Kitamura, Masashi; Aragane, Masako; Nakamura, Kou; Watanabe, Kazuhito; Sasaki, Yohei

    2017-01-01

    In Cannabis sativa L., tetrahydrocannabinol (THC) is the primary psychoactive compound and exists as the carboxylated form, tetrahydrocannabinolic acid (THCA). C. sativa is divided into two strains based on THCA content-THCA-rich (drug-type) strains and THCA-poor (fiber-type) strains. Both strains are prohibited by law in many countries including Japan, whereas the drug-type strains are regulated in Canada and some European countries. As the two strains cannot be discriminated by morphological analysis, a simple method for identifying the drug-type strains is required for quality control in legal cultivation and forensic investigation. We have developed a novel loop-mediated isothermal amplification (LAMP) assay for identifying the drug-type strains of C. sativa. We designed two selective LAMP primer sets for on-site or laboratory use, which target the drug-type THCA synthase gene. The LAMP assay was accomplished within approximately 40 min. The assay showed high specificity for the drug-type strains and its sensitivity was the same as or higher than that of conventional polymerase chain reaction. We also showed the effectiveness of melting curve analysis that was conducted after the LAMP assay. The melting temperature values of the drug-type strains corresponded to those of the cloned drug-type THCA synthase gene, and were clearly different from those of the cloned fiber-type THCA synthase gene. Moreover, the LAMP assay with simple sample preparation could be accomplished within 1 h from sample treatment to identification without the need for special devices or techniques. Our rapid, sensitive, specific, and simple assay is expected to be applicable to laboratory and on-site detection.

  9. Quality Assurance in the Polio Laboratory. Cell Sensitivity and Cell Authentication Assays.

    PubMed

    Dunn, Glynis

    2016-01-01

    The accuracy of poliovirus surveillance is largely dependent on the quality of the cell lines used for virus isolation, which is the foundation of poliovirus diagnostic work. Many cell lines are available for the isolation of enteroviruses, whilst genetically modified L20B cells can be used as a diagnostic tool for the identification of polioviruses. To be confident that cells can consistently isolate the virus of interest, it is necessary to have a quality assurance system in place, which will ensure that the cells in use are not contaminated with other cell lines or microorganisms and that they remain sensitive to the viruses being studied.The sensitivity of cell lines can be assessed by the regular testing of a virus standard of known titer in the cell lines used for virus isolation. The titers obtained are compared to previously obtained titers in the same assay, so that any loss of sensitivity can be detected.However, the detection of cell line cross contamination is more difficult. DNA bar coding is a technique that uses a short DNA sequence from a standardized position in the genome as a molecular diagnostic assay for species-level identification. For almost all groups of higher animals, the cytochrome c oxidase subunit 1 of mitochondrial DNA (CO1) is emerging as the standard barcode region. This region is 648 nucleotide base pairs long in most phylogenetic groups and is flanked by regions of conserved sequences, making it relatively easy to isolate and analyze. DNA barcodes vary among individuals of the same species to a very minor degree (generally less than 1-2 %), and a growing number of studies have shown that the COI sequences of even closely related species differ by several per cent, making it possible to identify different species with high confidence.

  10. Manual versus automated γ-H2AX foci analysis across five European laboratories: can this assay be used for rapid biodosimetry in a large scale radiation accident?

    PubMed

    Rothkamm, Kai; Barnard, Stephen; Ainsbury, Elizabeth A; Al-Hafidh, Jenna; Barquinero, Joan-Francesc; Lindholm, Carita; Moquet, Jayne; Perälä, Marjo; Roch-Lefèvre, Sandrine; Scherthan, Harry; Thierens, Hubert; Vral, Anne; Vandersickel, Veerle

    2013-08-30

    The identification of severely exposed individuals and reassurance of the 'worried well' are of prime importance for initial triage following a large scale radiation accident. We aim to develop the γ-H2AX foci assay into a rapid biomarker tool for use in accidents. Here, five laboratories established a standard operating procedure and analysed 100 ex vivo γ-irradiated, 4 or 24h incubated and overnight-shipped lymphocyte samples from four donors to generate γ-H2AX reference data, using manual and/or automated foci scoring strategies. In addition to acute, homogeneous exposures to 0, 1, 2 and 4Gy, acute simulated partial body (4Gy to 50% of cells) and protracted exposures (4Gy over 24h) were analysed. Data from all laboratories could be satisfactorily fitted with linear dose response functions. Average yields observed at 4h post exposure were 2-4 times higher than at 24h and varied considerably between laboratories. Automated scoring caused larger uncertainties than manual scoring and was unable to identify partial exposures, which were detectable in manually scored samples due to their overdispersed foci distributions. Protracted exposures were detectable but doses could not be accurately estimated with the γ-H2AX assay. We conclude that the γ-H2AX assay may be useful for rapid triage following a recent acute radiation exposure. The potentially higher speed and convenience of automated relative to manual foci scoring needs to be balanced against its compromised accuracy and inability to detect partial body exposures. Regular re-calibration or inclusion of reference samples may be necessary to ensure consistent results between laboratories or over long time periods. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  11. 21 CFR 226.58 - Laboratory controls.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Laboratory controls. Laboratory controls shall include the establishment of adequate specifications and test... establishment of master records containing appropriate specifications and a description of the test procedures... necessary laboratory test procedures to check such specifications. (c) Assays which shall be made of...

  12. Digital Assays Part II: Digital Protein and Cell Assays.

    PubMed

    Basu, Amar S

    2017-08-01

    A digital assay is one in which the sample is partitioned into many containers such that each partition contains a discrete number of biological entities (0, 1, 2, 3, . . .). A powerful technique in the biologist's toolkit, digital assays bring a new level of precision in quantifying nucleic acids, measuring proteins and their enzymatic activity, and probing single-cell genotype and phenotype. Where part I of this review focused on the fundamentals of partitioning and digital PCR, part II turns its attention to digital protein and cell assays. Digital enzyme assays measure the kinetics of single proteins with enzymatic activity. Digital enzyme-linked immunoassays (ELISAs) quantify antigenic proteins with 2 to 3 log lower detection limit than conventional ELISA, making them well suited for low-abundance biomarkers. Digital cell assays probe single-cell genotype and phenotype, including gene expression, intracellular and surface proteins, metabolic activity, cytotoxicity, and transcriptomes (scRNA-seq). These methods exploit partitioning to 1) isolate single cells or proteins, 2) detect their activity via enzymatic amplification, and 3) tag them individually by coencapsulating them with molecular barcodes. When scaled, digital assays reveal stochastic differences between proteins or cells within a population, a key to understanding biological heterogeneity. This review is intended to give a broad perspective to scientists interested in adopting digital assays into their workflows.

  13. Profile of Instrumentation Laboratory's HemosIL® AcuStar HIT-Ab(PF4-H) assay for diagnosis of heparin-induced thrombocytopenia.

    PubMed

    Nagler, Michael; Cuker, Adam

    2017-05-01

    Immunoassays play an essential role in the diagnosis of heparin-induced thrombocytopenia (HIT). The objective of this article is to review HemosIL® AcuStar HIT-Ab(PF4-H) (Instrumentation Laboratory, Bedford, MA, USA), a new chemiluminescent immunoassay for HIT. Areas covered: The authors searched the published literature for evaluation studies of HemosIL® AcuStar HIT-Ab(PF4-H) and sought information from the manufacturer. In this paper, the authors discuss the analytical principle and technical aspects of the assay; describe its diagnostic performance in validation studies; report on its reproducibility, cost-effectiveness, and regulatory status; and discuss the implications of the assay on clinical practice and means of integrating it in diagnostic pathways. HemosIL® AcuStar HIT-Ab(PF4-H) is compared with other rapid assays and widely used enzyme-linked immunoassays for the diagnosis of HIT. Expert commentary: HemosIL® AcuStar HIT-Ab(PF4-H) is automatable, can be performed 24 h per day, offers a rapid turnaround time, and appears to have favorable diagnostic accuracy, particularly at thresholds above that listed in the label. These advantages could lead to improved patient outcomes through rapid provision of results at the point of care, enhancing the accuracy of initial diagnosis.

  14. Validation of the Filovirus Plaque Assay for Use in Preclinical Studies

    PubMed Central

    Shurtleff, Amy C.; Bloomfield, Holly A.; Mort, Shannon; Orr, Steven A.; Audet, Brian; Whitaker, Thomas; Richards, Michelle J.; Bavari, Sina

    2016-01-01

    A plaque assay for quantitating filoviruses in virus stocks, prepared viral challenge inocula and samples from research animals has recently been fully characterized and standardized for use across multiple institutions performing Biosafety Level 4 (BSL-4) studies. After standardization studies were completed, Good Laboratory Practices (GLP)-compliant plaque assay method validation studies to demonstrate suitability for reliable and reproducible measurement of the Marburg Virus Angola (MARV) variant and Ebola Virus Kikwit (EBOV) variant commenced at the United States Army Medical Research Institute of Infectious Diseases (USAMRIID). The validation parameters tested included accuracy, precision, linearity, robustness, stability of the virus stocks and system suitability. The MARV and EBOV assays were confirmed to be accurate to ±0.5 log10 PFU/mL. Repeatability precision, intermediate precision and reproducibility precision were sufficient to return viral titers with a coefficient of variation (%CV) of ≤30%, deemed acceptable variation for a cell-based bioassay. Intraclass correlation statistical techniques for the evaluation of the assay’s precision when the same plaques were quantitated by two analysts returned values passing the acceptance criteria, indicating high agreement between analysts. The assay was shown to be accurate and specific when run on Nonhuman Primates (NHP) serum and plasma samples diluted in plaque assay medium, with negligible matrix effects. Virus stocks demonstrated stability for freeze-thaw cycles typical of normal usage during assay retests. The results demonstrated that the EBOV and MARV plaque assays are accurate, precise and robust for filovirus titration in samples associated with the performance of GLP animal model studies. PMID:27110807

  15. Tritium assay of Li/sub 2/O in the LBM/LOTUS experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quanci, J.; Azam, S.; Bertone, P.

    1986-11-01

    The Lithium Blanket Module (LBM) is an assembly of over 20,000 cylindrical lithium oxide pellets in an array representative of a limited-coverage breeding zone for a toroidal fusion device. A principal objective of the LBM program is to test the ability of advanced neutronics coding to model the tritium breeding characteristics of a fusion device blanket. The LBM has been irradiated at the Ecole Polytechnique Federale de Lausanne (EPFL) LOTUS facility with a 14 MeV point-neutron source. Princeton Plasma Physics Laboratory (PPPL) and EPFL assayed the tritium bred in lithium oxide diagnostic samples placed at various positions in the LBM.more » PPPL employed a thermal extraction technique while EPFL used a dissolution method. The results for the assay are reported and compared to MCNP Monte Carlo neutronics calculations for the LBM/LOTUS system.« less

  16. Laboratory Testing Protocols for Heparin-Induced Thrombocytopenia (HIT) Testing.

    PubMed

    Lau, Kun Kan Edwin; Mohammed, Soma; Pasalic, Leonardo; Favaloro, Emmanuel J

    2017-01-01

    Heparin-induced thrombocytopenia (HIT) represents a significant high morbidity complication of heparin therapy. The clinicopathological diagnosis of HIT remains challenging for many reasons; thus, laboratory testing represents an important component of an accurate diagnosis. Although there are many assays available to assess HIT, these essentially fall into two categories-(a) immunological assays, and (b) functional assays. The current chapter presents protocols for several HIT assays, being those that are most commonly performed in laboratory practice and have the widest geographic distribution. These comprise a manual lateral flow-based system (STiC), a fully automated latex immunoturbidimetric assay, a fully automated chemiluminescent assay (CLIA), light transmission aggregation (LTA), and whole blood aggregation (Multiplate).

  17. Comparison of Estrogen Receptor Assay Results from Pathology Reports with Results from Central Laboratory Testing: Implications for Population-Based Studies of Breast Cancer

    PubMed Central

    Collins, LC; Marotti, J; Baer, HJ; Deitz, AC; Colditz, GA; Tamimi, RM

    2014-01-01

    Population-based studies of women with breast cancer commonly utilize information culled from pathology reports rather than central pathology review. The reliability of this information, particularly with regard to tumor biomarker results, is of concern. To address this, we evaluated the concordance between estrogen receptor (ER) results as determined from the original pathology reports and ER results obtained on the same specimens following testing in a single laboratory. Tissue microarrays (TMAs) were constructed from paraffin blocks of 3,167 breast cancers that developed in women enrolled in the Nurses’ Health Study. ER immunostains were performed on all TMA sections in single run. Results of ER immunostains performed on the TMA sections were compared with ER assay results abstracted from pathology reports. Among 1,851 cases of invasive breast cancer in which both ER results from pathology reports and central ER test results were available, the reported ER status and the ER status as determined from immunostains on TMAs were in agreement in 1,651 cases (87.3 %; kappa value 0.64, p<0.0001). When the comparison was restricted to ER assays originally performed by immunohistochemistry, the agreement rate increased to 92.3% (kappa value 0.78, p<0.0001). These results provide a framework for the accuracy of ER results abstracted from clinical records. Further, they suggest that utilizing ER assay results from pathology reports is a reasonable, albeit imperfect, alternative to central laboratory ER testing for large, population-based studies of patients with breast cancer. PMID:18230800

  18. Laboratory assays evaluate the influence of physical guidelines on subterranean termite (Isoptera: Rhinotermitidae) tunneling, bait discovery, and consumption.

    PubMed

    Swoboda, L E; Miller, D M

    2004-08-01

    Laboratory assays were conducted to determine whether physical guidelines could direct subterranean termite foraging behavior. Several materials (wood, plastics, and wood thermoplastic composites) were evaluated for their potential to serve as termite guidelines. Termite tunneling along the different types of guidelines was measured. The proportion of baits discovered when connected by a guideline was compared with the proportion of unconnected baits discovered. Termite consumption of baits also was quantified. Assay results indicated that the termites did not respond to all guideline materials in the same way. Termites built significantly longer tunnels along wood guidelines than they did along any of the plastic guidelines tested. However, tunnel length along the wood and the wood thermoplastic composites was not significantly different. The probability of two baits being discovered when they were connected by wood guidelines was significantly greater than when the baits were connected by plastic guidelines or left unconnected (no guideline). Pairs of baits connected by wood thermoplastic composites were also significantly more likely to be discovered than unconnected baits. Bait consumption was not enhanced by the presence of the guidelines. It is likely that guidelines made of wood competed with the baits as a termite food resource.

  19. An Enzymatic Clinical Chemistry Laboratory Experiment Incorporating an Introduction to Mathematical Method Comparison Techniques

    ERIC Educational Resources Information Center

    Duxbury, Mark

    2004-01-01

    An enzymatic laboratory experiment based on the analysis of serum is described that is suitable for students of clinical chemistry. The experiment incorporates an introduction to mathematical method-comparison techniques in which three different clinical glucose analysis methods are compared using linear regression and Bland-Altman difference…

  20. Impact of the New Abbott mPLUS Feature on Clinical Laboratory Efficiencies of Abbott RealTime Assays for Detection of HIV-1, Hepatitis C Virus, Hepatitis B Virus, Chlamydia trachomatis, and Neisseria gonorrhoeae

    PubMed Central

    Jones, Sara; Wiesneth, Russ; Barry, Cathy; Webb, Erika; Belova, Larissa; Dolan, Peggy; Ho, Shiaolan; Abravaya, Klara; Cloherty, Gavin

    2013-01-01

    Diagnostic laboratories are under increasing pressure to improve and expand their services. Greater flexibility in sample processing is a critical factor that can improve the time to results while reducing reagent waste, making laboratories more efficient and cost-effective. The introduction of the Abbott mPLUS feature, with the capacity for extended use of amplification reagents, significantly increases the flexibility of the m2000 platform and enables laboratories to customize their workflows based on sample arrival patterns. The flexibility in sample batch size offered by mPLUS enables significant reductions in processing times. For hepatitis B virus tests, a reduction in sample turnaround times of up to 30% (105 min) was observed for batches of 12 samples compared with those for batches of 24 samples; for Chlamydia trachomatis/Neisseria gonorrhoeae tests, the ability to run batches of 24 samples reduced the turnaround time by 83% (54 min) compared with that for batches of 48 samples. Excellent correlations between mPLUS and m2000 standard condition results were observed for all RealTime viral load assays evaluated in this study, with correlation r values of 0.998 for all assays tested. For the qualitative RealTime C. trachomatis/N. gonorrhoeae assay, the overall agreements between the two conditions tested were >98% for C. trachomatis and 100% for N. gonorrhoeae. Comparable precision results were observed for the two conditions tested for all RealTime assays. The enhanced mPLUS capability provides clinical laboratories with increased efficiencies to meet increasingly stringent turnaround time requirements without increased costs associated with discarding partially used amplification reagents. PMID:24088850

  1. Impact of the New Abbott mPLUS feature on clinical laboratory efficiencies of abbott RealTime assays for detection of HIV-1, Hepatitis C Virus, Hepatitis B Virus, Chlamydia trachomatis, and Neisseria gonorrhoeae.

    PubMed

    Lucic, Danijela; Jones, Sara; Wiesneth, Russ; Barry, Cathy; Webb, Erika; Belova, Larissa; Dolan, Peggy; Ho, Shiaolan; Abravaya, Klara; Cloherty, Gavin

    2013-12-01

    Diagnostic laboratories are under increasing pressure to improve and expand their services. Greater flexibility in sample processing is a critical factor that can improve the time to results while reducing reagent waste, making laboratories more efficient and cost-effective. The introduction of the Abbott mPLUS feature, with the capacity for extended use of amplification reagents, significantly increases the flexibility of the m2000 platform and enables laboratories to customize their workflows based on sample arrival patterns. The flexibility in sample batch size offered by mPLUS enables significant reductions in processing times. For hepatitis B virus tests, a reduction in sample turnaround times of up to 30% (105 min) was observed for batches of 12 samples compared with those for batches of 24 samples; for Chlamydia trachomatis/Neisseria gonorrhoeae tests, the ability to run batches of 24 samples reduced the turnaround time by 83% (54 min) compared with that for batches of 48 samples. Excellent correlations between mPLUS and m2000 standard condition results were observed for all RealTime viral load assays evaluated in this study, with correlation r values of 0.998 for all assays tested. For the qualitative RealTime C. trachomatis/N. gonorrhoeae assay, the overall agreements between the two conditions tested were >98% for C. trachomatis and 100% for N. gonorrhoeae. Comparable precision results were observed for the two conditions tested for all RealTime assays. The enhanced mPLUS capability provides clinical laboratories with increased efficiencies to meet increasingly stringent turnaround time requirements without increased costs associated with discarding partially used amplification reagents.

  2. Implementation of Good Clinical Laboratory Practice (GCLP) guidelines within the External Quality Assurance Program Oversight Laboratory (EQAPOL).

    PubMed

    Todd, Christopher A; Sanchez, Ana M; Garcia, Ambrosia; Denny, Thomas N; Sarzotti-Kelsoe, Marcella

    2014-07-01

    The EQAPOL contract was awarded to Duke University to develop and manage global proficiency testing programs for flow cytometry-, ELISpot-, and Luminex bead-based assays (cytokine analytes), as well as create a genetically diverse panel of HIV-1 viral cultures to be made available to National Institutes of Health (NIH) researchers. As a part of this contract, EQAPOL was required to operate under Good Clinical Laboratory Practices (GCLP) that are traditionally used for laboratories conducting endpoint assays for human clinical trials. EQAPOL adapted these guidelines to the management of proficiency testing programs while simultaneously incorporating aspects of ISO/IEC 17043 which are specifically designed for external proficiency management. Over the first two years of the contract, the EQAPOL Oversight Laboratories received training, developed standard operating procedures and quality management practices, implemented strict quality control procedures for equipment, reagents, and documentation, and received audits from the EQAPOL Central Quality Assurance Unit. GCLP programs, such as EQAPOL, strengthen a laboratory's ability to perform critical assays and provide quality assessments of future potential vaccines. © 2013.

  3. Against the proposition: for the diagnosis of viral infections, commercial assays provide more reliable results than do in-house assays.

    PubMed

    James, Vivienne

    2008-01-01

    There are no differences inherent in the design of commercial or in-house assays and their early development is similar. The same principles apply and it is on the same criteria of accuracy, reproducibility and clinical relevance of results that all assays are judged. However, if there is sufficient uptake of a commercial assay, its strengths and any flaws soon become apparent and it will only be the best commercial assays that remain in the market. For the in-house assays it is through comparability studies and external quality assessment (EQA) schemes that the best can be demonstrated, albeit this information is only accessible initially to the EQA provider and the laboratories using the assays. The EQA results described here support my supposition that, for the diagnosis of viral infections, commercial assays do not provide more reliable results than do in-house assays.

  4. International network for comparison of HIV neutralization assays: the NeutNet report.

    PubMed

    Fenyö, Eva Maria; Heath, Alan; Dispinseri, Stefania; Holmes, Harvey; Lusso, Paolo; Zolla-Pazner, Susan; Donners, Helen; Heyndrickx, Leo; Alcami, Jose; Bongertz, Vera; Jassoy, Christian; Malnati, Mauro; Montefiori, David; Moog, Christiane; Morris, Lynn; Osmanov, Saladin; Polonis, Victoria; Sattentau, Quentin; Schuitemaker, Hanneke; Sutthent, Ruengpung; Wrin, Terri; Scarlatti, Gabriella

    2009-01-01

    Neutralizing antibody assessments play a central role in human immunodeficiency virus type-1 (HIV-1) vaccine development but it is unclear which assay, or combination of assays, will provide reliable measures of correlates of protection. To address this, an international collaboration (NeutNet) involving 18 independent participants was organized to compare different assays. Each laboratory evaluated four neutralizing reagents (TriMab, 447-52D, 4E10, sCD4) at a given range of concentrations against a panel of 11 viruses representing a wide range of genetic subtypes and phenotypes. A total of 16 different assays were compared. The assays utilized either uncloned virus produced in peripheral blood mononuclear cells (PBMCs) (virus infectivity assays, VI assays), or their Env-pseudotyped (gp160) derivatives produced in 293T cells (PSV assays) from molecular clones or uncloned virus. Target cells included PBMC and genetically-engineered cell lines in either a single- or multiple-cycle infection format. Infection was quantified by using a range of assay read-outs that included extracellular or intracellular p24 antigen detection, RNA quantification and luciferase and beta-galactosidase reporter gene expression. PSV assays were generally more sensitive than VI assays, but there were important differences according to the virus and inhibitor used. For example, for TriMab, the mean IC50 was always lower in PSV than in VI assays. However, with 4E10 or sCD4 some viruses were neutralized with a lower IC50 in VI assays than in the PSV assays. Inter-laboratory concordance was slightly better for PSV than for VI assays with some viruses, but for other viruses agreement between laboratories was limited and depended on both the virus and the neutralizing reagent. The NeutNet project demonstrated clear differences in assay sensitivity that were dependent on both the neutralizing reagent and the virus. No single assay was capable of detecting the entire spectrum of neutralizing

  5. Techniques for determining total body water using deuterium oxide

    NASA Technical Reports Server (NTRS)

    Bishop, Phillip A.

    1990-01-01

    The measurement of total body water (TBW) is fundamental to the study of body fluid changes consequent to microgravity exposure or treatment with microgravity countermeasures. Often, the use of radioactive isotopes is prohibited for safety or other reasons. It was selected and implemented for use by some Johnson Space Center (JCS) laboratories, which permitted serial measurements over a 14 day period which was accurate enough to serve as a criterion method for validating new techniques. These requirements resulted in the selection of deuterium oxide dilution as the method of choice for TBW measurement. The development of this technique at JSC is reviewed. The recommended dosage, body fluid sampling techniques, and deuterium assay options are described.

  6. Laboratory Techniques for the Blind

    ERIC Educational Resources Information Center

    Tombaugh, Dorothy

    1972-01-01

    Describes modifications of laboratory procedures for the BSCS Green Version biology, including dissection, microbiology, animal behavior, physiology, biochemistry, and genetics that make the methods suitable for direct experimentation by blind students. Discusses models as substitutes for microscopy. (AL)

  7. Interpreting the Laboratory Reports for Vit D.

    PubMed

    Sarmah, Devajit; Sharma, Booloo

    2014-09-01

    Importance for Vit D estimation has increased in the recent years due to its link to various diseases. Measurements of Vit D by different diagnostic laboratories is however not uniform. There is variation pertaining to assay methodology and also variation in the measurement of different metabolites of Vit D. There are also various confounders which influence Vit D assays and which in most instances are overlooked. Also a matter of concern regarding Vit D assays is the lack of assay standardisation. These factors contribute to the variation in the reports generated by the diagnostic laboratories. Therefore interpretation of Vit D reports needs proper understanding of these interfering factors and further reports need to be correlated substantially with the clinical findings.

  8. In Situ Protein Binding Assay Using Fc-Fusion Proteins.

    PubMed

    Padmanabhan, Nirmala; Siddiqui, Tabrez J

    2017-01-01

    This protocol describes an in situ protein-protein interaction assay between tagged recombinant proteins and cell-surface expressed synaptic proteins. The assay is arguably more sensitive than other traditional protein binding assays such as co-immunoprecipitation and pull-downs and provides a visual readout for binding. This assay has been widely used to determine the dissociation constant of binding of trans-synaptic adhesion proteins. The step-wise description in the protocol should facilitate the adoption of this method in other laboratories.

  9. Accelerated Colorimetric Micro-assay for Screening Mold Inhibitors

    Treesearch

    Carol A. Clausen; Vina W. Yang

    2014-01-01

    Rapid quantitative laboratory test methods are needed to screen potential antifungal agents. Existing laboratory test methods are relatively time consuming, may require specialized test equipment and rely on subjective visual ratings. A quantitative, colorimetric micro-assay has been developed that uses XTT tetrazolium salt to metabolically assess mold spore...

  10. Applications of nuclear techniques for in vivo body composition studies at Brookhaven National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cohn, S.H.; Ellis, K.J.; Vartsky, D.

    1981-01-01

    A series of technical developments and their clinical applications in various nuclear technologies at Brookhaven National Laboratory is described. These include the development of a portable neutron activation facility for measuring cadmium in vivo in kidney and liver, a technique for the measurement of body iron utilizing nuclear resonant scattering of gamma rays, a non-invasive measure of the skeletal levels of lead by an x-ray fluorescence technique, and the development of a pulsed Van de Graaff generator as a source of pulsed neutrons for the measurement of lung silicon. (ACR)

  11. Factor Activity Assays for Monitoring Extended Half-Life FVIII and Factor IX Replacement Therapies.

    PubMed

    Kitchen, Steve; Tiefenbacher, Stefan; Gosselin, Robert

    2017-04-01

    The advent of modified factor VIII (FVIII) and factor IX (FIX) molecules with extended half-lives (EHLs) compared with native FVIII and FIX represents a major advance in the field of hemophilia care, with the potential to reduce the frequency of prophylactic injections and/or to increase the trough level prior to subsequent injections. Monitoring treatment through laboratory assays will be an important part of ensuring patient safety, including any tailoring of prophylaxis. Several approaches have been used to extend half-lives, including PEGylation, and fusion to albumin or immunoglobulin. Some of these modifications affect factor assays as routinely performed in hemophilia centers; so, laboratories will need to use FVIII and FIX assays which have been shown to be suitable on a product-by-product basis. For some products, there are marked differences between results obtained using one-stage or chromogenic assays and results obtained using different reagents in the one-stage assay. The laboratory should use an assay in which the recovery of the product closely aligns with the assay used by the pharmaceutical company to assign potency to the product, so that the units reported by the laboratory agree with those used to demonstrate efficacy of the product during clinical trials. Reported assay differences in relation to several of the EHL FVIII and FIX molecules will be reviewed in this article. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  12. Assay techniques for detection of exposure to sulfur mustard, cholinesterase inhibitors, sarin, soman, GF, and cyanide. Technical bulletin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-05-01

    This technical bulletin provides analytical techniques to identify toxic chemical agents in urine or blood samples. It is intended to provide the clinician with laboratory tests to detect exposure to sulfur mustard, cholinesterase inhibitors, sarin, soman, GF, and cyanide.

  13. Audit of Use and Overuse of Serum Protein Immunofixation Electrophoresis and Serum Free Light Chain Assay in Tertiary Health Care: A Case for Algorithmic Testing to Optimize Laboratory Utilization.

    PubMed

    Heaton, Christopher; Vyas, Shikhar G; Singh, Gurmukh

    2016-04-01

    Overuse of laboratory tests is a persistent issue. We examined the use and overuse of serum immunofixation electrophoresis and serum free light chain assays to develop an algorithm for optimizing utilization. A retrospective review of all tests, for investigation of monoclonal gammopathies, for all patients who had any of these tests done from April 24, 2014, through July 25, 2014, was carried out. The test orders were categorized as warranted or not warranted according to criteria presented in the article. A total of 237 patients were tested, and their historical records included 1,503 episodes of testing for one or more of serum protein electrophoresis, serum immunofixation electrophoresis, and serum free light chain assays. Only 46% of the serum immunofixation and 42% serum free light chain assays were warranted. Proper utilization, at our institution alone, would have obviated $64,182.95/year in health care costs, reduced laboratory cost of reagent alone by $26,436.04/year, and put $21,904.92/year of part B reimbursement at risk. Fewer than half of the serum immunofixation and serum free light chain assays added value. The proposed algorithm for testing should improve utilization. Risk to part B billing may be a disincentive to reducing test utilization. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  14. Differences in serum thyroglobulin measurements by 3 commercial immunoradiometric assay kits and laboratory standardization using Certified Reference Material 457 (CRM-457).

    PubMed

    Lee, Ji In; Kim, Ji Young; Choi, Joon Young; Kim, Hee Kyung; Jang, Hye Won; Hur, Kyu Yeon; Kim, Jae Hyeon; Kim, Kwang-Won; Chung, Jae Hoon; Kim, Sun Wook

    2010-09-01

    Serum thyroglobulin (Tg) is essential in the follow-up of patients with differentiated thyroid carcinoma (DTC). However, interchangeability and standardization between Tg assays have not yet been achieved, even with the development of an international Tg standard (Certified Reference Material 457 [CRM-457]). Serum Tg from 30 DTC patients and serially diluted CRM-457 were measured using 3 different immunoradiometric assays (IRMA-1, IRMA-2, IRMA-3). The intraclass correlation coefficient (ICC) method was used to describe the concordance of each IRMA to CRM-457. The serum Tg measured by 3 different IRMAs correlated well (r > .85, p < .0001), but clinically relevant discrepancies were found in 13.3% of patients. IRMA-3, which claims to be standardized to CRM-457, showed the best ICC (p(1) = .98) for the CRM-457. Hospitals caring for patients with DTC should either set their own cutoffs for IRMAs for Tg based on their patient pools, or adopt IRMAs standardized to CRM-457 and calibrate their laboratory using CRM-457.

  15. A single-islet microplate assay to measure mouse and human islet insulin secretion.

    PubMed

    Truchan, Nathan A; Brar, Harpreet K; Gallagher, Shannon J; Neuman, Joshua C; Kimple, Michelle E

    2015-01-01

    One complication to comparing β-cell function among islet preparations, whether from genetically identical or diverse animals or human organ donors, is the number of islets required per assay. Islet numbers can be limiting, meaning that fewer conditions can be tested; other islet measurements must be excluded; or islets must be pooled from multiple animals/donors for each experiment. Furthermore, pooling islets negates the possibility of performing single-islet comparisons. Our aim was to validate a 96-well plate-based single islet insulin secretion assay that would be as robust as previously published methods to quantify glucose-stimulated insulin secretion from mouse and human islets. First, we tested our new assay using mouse islets, showing robust stimulation of insulin secretion 24 or 48 h after islet isolation. Next, we utilized the assay to quantify mouse islet function on an individual islet basis, measurements that would not be possible with the standard pooled islet assay methods. Next, we validated our new assay using human islets obtained from the Integrated Islet Distribution Program (IIDP). Human islets are known to have widely varying insulin secretion capacity, and using our new assay we reveal biologically relevant factors that are significantly correlated with human islet function, whether displayed as maximal insulin secretion response or fold-stimulation of insulin secretion. Overall, our results suggest this new microplate assay will be a useful tool for many laboratories, expert or not in islet techniques, to be able to precisely quantify islet insulin secretion from their models of interest.

  16. Nucleic Acid Amplification Based Diagnostic of Lyme (Neuro-)borreliosis – Lost in the Jungle of Methods, Targets, and Assays?

    PubMed Central

    Nolte, Oliver

    2012-01-01

    Laboratory based diagnosis of infectious diseases usually relies on culture of the disease causing micro-organism, followed by identification and susceptibility testing. Since Borrelia burgdorferi sensu lato, the etiologic agent of Lyme disease or Lyme borreliosis, requires very specific culture conditions (e.g. specific liquid media, long term cul-ture) traditional bacteriology is often not done on a routine basis. Instead, confirmation of the clinical diagnosis needs ei-ther indirect techniques (like serology or measurement of cellular activity in the presence of antigens) or direct but culture independent techniques, like microscopy or nucleic acid amplification techniques (NAT), with polymerase chain reaction (PCR) being the most frequently applied NAT method in routine laboratories. NAT uses nucleic acids of the disease causing micro-organism as template for amplification, isolated from various sources of clinical specimens. Although the underlying principle, adoption of the enzymatic process running during DNA duplication prior to prokaryotic cell division, is comparatively easy, a couple of ‘pitfalls’ is associated with the technique itself as well as with interpretation of the results. At present, no commercial, CE-marked and sufficiently validated PCR assay is available. A number of homebrew assays have been published, which are different in terms of target (i.e. the gene targeted by the amplification primers), method (nested PCR, PCR followed by hybridization, real-time PCR) and validation criteria. Inhibitory compounds may lead to false negative results, if no appropriate internal control is included. Carry-over of amplicons, insufficient handling and workflow and/or insufficiently validated targets/primers may result in false positive results. Different targets may yield different analytical sensitivity, depending, among other factors, of the redundancy of a target gene in the genome. Per-formance characteristics (e.g. analytical sensitivity and

  17. Laboratory analyses of micron-sized solid grains: Experimental techniques and recent results

    NASA Technical Reports Server (NTRS)

    Colangeli, L.; Bussoletti, E.; Blanco, A.; Borghesi, A.; Fonti, S.; Orofino, V.; Schwehm, G.

    1989-01-01

    Morphological and spectrophotometric investigations have been extensively applied in the past years to various kinds of micron and/or submicron-sized grains formed by materials which are candidate to be present in space. The samples are produced in the laboratory and then characterized in their physio-chemical properties. Some of the most recent results obtained on various kinds of carbonaceous materials are reported. Main attention is devoted to spectroscopic results in the VUV and IR wavelength ranges, where many of the analyzed samples show typical fingerprints which can be identified also in astrophysical and cometary materials. The laboratory methodologies used so far are also critically discussed in order to point out capabilities and present limitations, in the view of possible application to returned comet samples. Suggestions are given to develop new techniques which should overcome some of the problems faced in the manipulation and analysis of micron solid samples.

  18. Guidelines on Good Clinical Laboratory Practice

    PubMed Central

    Ezzelle, J.; Rodriguez-Chavez, I. R.; Darden, J. M.; Stirewalt, M.; Kunwar, N.; Hitchcock, R.; Walter, T.; D’Souza, M. P.

    2008-01-01

    A set of Good Clinical Laboratory Practice (GCLP) standards that embraces both the research and clinical aspects of GLP were developed utilizing a variety of collected regulatory and guidance material. We describe eleven core elements that constitute the GCLP standards with the objective of filling a gap for laboratory guidance, based on IND sponsor requirements, for conducting laboratory testing using specimens from human clinical trials. These GCLP standards provide guidance on implementing GLP requirements that are critical for laboratory operations, such as performance of protocol-mandated safety assays, peripheral blood mononuclear cell processing and immunological or endpoint assays from biological interventions on IND-registered clinical trials. The expectation is that compliance with the GCLP standards, monitored annually by external audits, will allow research and development laboratories to maintain data integrity and to provide immunogenicity, safety, and product efficacy data that is repeatable, reliable, auditable and that can be easily reconstructed in a research setting. PMID:18037599

  19. The narrow therapeutic window of glycated hemoglobin and assay variability.

    PubMed

    Hosseini, S S; Bibler, I; Charles, M A

    1999-12-01

    Glycated hemoglobin is measured by a variety of assays, each of which has a unique normal level. Our purpose is to show that among the different assays available in the United States, using the same patient's blood sample, assay results may vary widely and may more or less easily achieve a glycated hemoglobin value within the normal range. The following assays were compared using the same patient's blood sample for each pair of assays: glycohemoglobin affinity assay (GHB Reader; Isolab, Akron, OH) versus gel electrophoresis assay (n = 76); Isolab versus ion capture assay (IMX; Abbott Laboratories, Irving, TX) (n = 57); monoclonal antibody assay (DCA2000; Bayer Diagnostics, Pittsburgh, PA) versus IMX (n = 100); and high-performance liquid chromatography (HPLC) assay (Bio-Rad Variant A1c; Bio-Rad Laboratories, Richmond, CA) versus IMX assay (n = 55). Our analyses indicate that a relative ranking can be established for the ease of achieving a normal glycated hemoglobin level. The ranking indicates that the most stringent or difficult assays for achieving a normal level are the Isolab and DCA2000 assays. The intermediate assays are the IMX and Bio-Rad Variant, and the easiest method for achieving a normal value is the gel electrophoresis assay. Our results indicate that various glycated hemoglobin assays vary widely and are associated with more or less difficulty for an individual patient to achieve a glycated hemoglobin level within the normal range. These results are especially significant with respect to (1) the clinically narrow therapeutic window of glycated hemoglobin values in type 1 diabetes to avoid rapidly advancing severe hypoglycemia rates and chronic microvascular complication rates, and (2) the glycated hemoglobin threshold for rapidly advancing macrovascular disease in both type 1 and type 2 patients.

  20. International Network for Comparison of HIV Neutralization Assays: The NeutNet Report

    PubMed Central

    Fenyö, Eva Maria; Heath, Alan; Dispinseri, Stefania; Holmes, Harvey; Lusso, Paolo; Zolla-Pazner, Susan; Donners, Helen; Heyndrickx, Leo; Alcami, Jose; Bongertz, Vera; Jassoy, Christian; Malnati, Mauro; Montefiori, David; Moog, Christiane; Morris, Lynn; Osmanov, Saladin; Polonis, Victoria; Sattentau, Quentin; Schuitemaker, Hanneke; Sutthent, Ruengpung; Wrin, Terri; Scarlatti, Gabriella

    2009-01-01

    Background Neutralizing antibody assessments play a central role in human immunodeficiency virus type-1 (HIV-1) vaccine development but it is unclear which assay, or combination of assays, will provide reliable measures of correlates of protection. To address this, an international collaboration (NeutNet) involving 18 independent participants was organized to compare different assays. Methods Each laboratory evaluated four neutralizing reagents (TriMab, 447-52D, 4E10, sCD4) at a given range of concentrations against a panel of 11 viruses representing a wide range of genetic subtypes and phenotypes. A total of 16 different assays were compared. The assays utilized either uncloned virus produced in peripheral blood mononuclear cells (PBMCs) (virus infectivity assays, VI assays), or their Env-pseudotyped (gp160) derivatives produced in 293T cells (PSV assays) from molecular clones or uncloned virus. Target cells included PBMC and genetically-engineered cell lines in either a single- or multiple-cycle infection format. Infection was quantified by using a range of assay read-outs that included extracellular or intracellular p24 antigen detection, RNA quantification and luciferase and beta-galactosidase reporter gene expression. Findings PSV assays were generally more sensitive than VI assays, but there were important differences according to the virus and inhibitor used. For example, for TriMab, the mean IC50 was always lower in PSV than in VI assays. However, with 4E10 or sCD4 some viruses were neutralized with a lower IC50 in VI assays than in the PSV assays. Inter-laboratory concordance was slightly better for PSV than for VI assays with some viruses, but for other viruses agreement between laboratories was limited and depended on both the virus and the neutralizing reagent. Conclusions The NeutNet project demonstrated clear differences in assay sensitivity that were dependent on both the neutralizing reagent and the virus. No single assay was capable of detecting

  1. Comparing ImmunoCard with two EIA assays for Clostridium difficile toxins.

    PubMed

    Chan, Edward L; Seales, Diane; Drum, Hong

    2009-01-01

    To compare three Clostridium difficile EIA kits for the detection of C. difficile toxins from clinical specimens. A total of 287 fresh and stored stool specimens were tested using all three assays. Stools with discrepant results were sent to a reference laboratory for tissue cytotoxin assay. Trinity Medical Center, a community hospital with network hospitals. Patients with diarrhea submitted stools for detection of C. difficile toxins. Of the 287 stool specimens, 116 were positive and 171 negative for C. difficile toxins. The sensitivity, specificity, and positive and negative predictive values of Meridian EIA assay were 99.1, 97.7, 96.6, and 99.4%; ImmunoCard were 100, 98.2, 97.5, and 100%; BioStar OIA assay were 94, 98.8, 98.2, and 96% respectively. ImmunoCardprovides the best sensitivity (100%) for C. difficile toxins A and B detection. The BioStar OIA rapid test missed seven positive stool specimens possibly due to failure to detect toxin B. ImmunoCard has slightly higher predictive values, shorter turnaround time and greater convenience compared to the Meridian EIA Assay. ImmunoCard may be cost effective not only in smaller laboratories, but also in high volume laboratories, when used on a STAT basis or single request.

  2. Manual of Basic Techniques for a Health Laboratory.

    ERIC Educational Resources Information Center

    World Health Organization, Geneva (Switzerland).

    Described are basic laboratory methods for diagnosing and investigating diseases of importance to developing countries. Intended primarily for the training of technicians who will work in peripheral laboratories, the manual is designed so that student laboratory assistants can be taught to use it with minimal supervision from a teacher. The…

  3. The EpiDerm™ 3D human reconstructed skin micronucleus (RSMN) assay: Historical control data and proof of principle studies for mechanistic assay adaptations.

    PubMed

    Roy, Shambhu; Kulkarni, Rohan; Hewitt, Nicola J; Aardema, Marilyn J

    2016-07-01

    The in vitro human reconstructed skin micronucleus (RSMN) assay in EpiDerm™ is a promising novel animal alternative for evaluating genotoxicity of topically applied chemicals. It is particularly useful for assessing cosmetic ingredients that can no longer be tested using in vivo assays. To advance the use of this test especially for regulatory decision-making, we have established the RSMN assay in our laboratory according to Good Laboratory Practice and following the principles of the OECD test guideline 487 in vitro mammalian cell micronucleus test. Proficiency with the assay was established by correctly identifying direct-acting genotoxins and genotoxins requiring metabolism, as well as non-genotoxic/non-carcinogenic chemicals. We also report the analysis of our historical control data that demonstrate vehicle control and positive control values for %micronuclei in binucleated cells are in the ranges reported previously. Technical issues including evaluating various solvents with both 48h and 72h treatment regimens were investigated. For the first time, mechanistic studies using CREST analysis revealed that the RSMN assay is suitable for distinguishing aneugens and clastogens. Moreover, the assay is also suitable for measuring cytokines as markers for proliferative and toxic effects of chemicals. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Immunological tools: engaging students in the use and analysis of flow cytometry and enzyme-linked immunosorbent assay (ELISA).

    PubMed

    Ott, Laura E; Carson, Susan

    2014-01-01

    Flow cytometry and enzyme-linked immunosorbent assay (ELISA) are commonly used techniques associated with clinical and research applications within the immunology and medical fields. The use of these techniques is becoming increasingly valuable in many life science and engineering disciplines as well. Herein, we report the development and evaluation of a novel half-semester course that focused on introducing undergraduate and graduate students to advance conceptual and technical skills associated with flow cytometry and ELISA, with emphasis on applications, experimental design, and data analysis. This course was offered in the North Carolina State University Biotechnology Program over three semesters and consisted of weekly lectures and laboratories. Students performed and/or analyzed flow cytometry and ELISA in three separate laboratory exercises: (1) identification of transgenic zebrafish hematopoietic cells, (2) analysis of transfection efficiency, and (3) analysis of cytokine production upon lipopolysaccharide stimulation. Student learning outcomes were achieved as demonstrated by multiple means of assessment, including three laboratory reports, a data analysis laboratory practicum, and a cumulative final exam. Further, anonymous student self-assessment revealed increased student confidence in the knowledge and skill sets defined in the learning outcomes. Copyright © 2014 The International Union of Biochemistry and Molecular Biology.

  5. Synchronous in-field application of life-detection techniques in planetary analog missions

    NASA Astrophysics Data System (ADS)

    Amador, Elena S.; Cable, Morgan L.; Chaudry, Nosheen; Cullen, Thomas; Gentry, Diana; Jacobsen, Malene B.; Murukesan, Gayathri; Schwieterman, Edward W.; Stevens, Adam H.; Stockton, Amanda; Yin, Chang; Cullen, David C.; Geppert, Wolf

    2015-02-01

    Field expeditions that simulate the operations of robotic planetary exploration missions at analog sites on Earth can help establish best practices and are therefore a positive contribution to the planetary exploration community. There are many sites in Iceland that possess heritage as planetary exploration analog locations and whose environmental extremes make them suitable for simulating scientific sampling and robotic operations. We conducted a planetary exploration analog mission at two recent lava fields in Iceland, Fimmvörðuháls (2010) and Eldfell (1973), using a specially developed field laboratory. We tested the utility of in-field site sampling down selection and tiered analysis operational capabilities with three life detection and characterization techniques: fluorescence microscopy (FM), adenine-triphosphate (ATP) bioluminescence assay, and quantitative polymerase chain reaction (qPCR) assay. The study made use of multiple cycles of sample collection at multiple distance scales and field laboratory analysis using the synchronous life-detection techniques to heuristically develop the continuing sampling and analysis strategy during the expedition. Here we report the operational lessons learned and provide brief summaries of scientific data. The full scientific data report will follow separately. We found that rapid in-field analysis to determine subsequent sampling decisions is operationally feasible, and that the chosen life detection and characterization techniques are suitable for a terrestrial life-detection field mission. In-field analysis enables the rapid obtainment of scientific data and thus facilitates the collection of the most scientifically relevant samples within a single field expedition, without the need for sample relocation to external laboratories. The operational lessons learned in this study could be applied to future terrestrial field expeditions employing other analytical techniques and to future robotic planetary exploration

  6. Nuclear Resonance Fluorescence for Materials Assay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quiter, Brian; Ludewigt, Bernhard; Mozin, Vladimir

    This paper discusses the use of nuclear resonance fluorescence (NRF) techniques for the isotopic and quantitative assaying of radioactive material. Potential applications include age-dating of an unknown radioactive source, pre- and post-detonation nuclear forensics, and safeguards for nuclear fuel cycles Examples of age-dating a strong radioactive source and assaying a spent fuel pin are discussed. The modeling work has ben performed with the Monte Carlo radiation transport computer code MCNPX, and the capability to simulate NRF has bee added to the code. Discussed are the limitations in MCNPX's photon transport physics for accurately describing photon scattering processes that are importantmore » contributions to the background and impact the applicability of the NRF assay technique.« less

  7. Nuclear Resonance Fluorescence for Materials Assay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quiter, Brian J.; Ludewigt, Bernhard; Mozin, Vladimir

    This paper discusses the use of nuclear resonance fluorescence (NRF) techniques for the isotopic and quantitative assaying of radioactive material. Potential applications include age-dating of an unknown radioactive source, pre- and post-detonation nuclear forensics, and safeguards for nuclear fuel cycles Examples of age-dating a strong radioactive source and assaying a spent fuel pin are discussed. The modeling work has ben performed with the Monte Carlo radiation transport computer code MCNPX, and the capability to simulate NRF has bee added to the code. Discussed are the limitations in MCNPX?s photon transport physics for accurately describing photon scattering processes that are importantmore » contributions to the background and impact the applicability of the NRF assay technique.« less

  8. Comprehensive Laboratory Evaluation of a Highly Specific Lateral Flow Assay for the Presumptive Identification of Bacillus anthracis Spores in Suspicious White Powders and Environmental Samples

    PubMed Central

    Ramage, Jason G.; Prentice, Kristin W.; DePalma, Lindsay; Venkateswaran, Kodumudi S.; Chivukula, Sruti; Chapman, Carol; Bell, Melissa; Datta, Shomik; Singh, Ajay; Hoffmaster, Alex; Sarwar, Jawad; Parameswaran, Nishanth; Joshi, Mrinmayi; Thirunavkkarasu, Nagarajan; Krishnan, Viswanathan; Morse, Stephen; Avila, Julie R.; Sharma, Shashi; Estacio, Peter L.; Stanker, Larry; Hodge, David R.

    2016-01-01

    We conducted a comprehensive, multiphase laboratory evaluation of the Anthrax BioThreat Alert® test strip, a lateral flow immunoassay (LFA) for the rapid detection of Bacillus anthracis spores. The study, conducted at 2 sites, evaluated this assay for the detection of spores from the Ames and Sterne strains of B. anthracis, as well as those from an additional 22 strains. Phylogenetic near neighbors, environmental background organisms, white powders, and environmental samples were also tested. The Anthrax LFA demonstrated a limit of detection of about 106 spores/mL (ca. 1.5 × 105 spores/assay). In this study, overall sensitivity of the LFA was 99.3%, and the specificity was 98.6%. The results indicated that the specificity, sensitivity, limit of detection, dynamic range, and repeatability of the assay support its use in the field for the purpose of qualitatively evaluating suspicious white powders and environmental samples for the presumptive presence of B. anthracis spores. PMID:27661796

  9. Evaluation of a new serological technique for detecting rabies virus antibodies following vaccination.

    PubMed

    Ma, Xiaoyue; Niezgoda, Michael; Blanton, Jesse D; Recuenco, Sergio; Rupprecht, Charles E

    2012-08-03

    Two major techniques are currently used to estimate rabies virus antibody values: neutralization assays, such as the rapid fluorescent focus inhibition test (RFFIT), and enzyme-linked immunosorbent assays (ELISAs). The RFFIT is considered the gold standard assay and has been used to assess the titer of rabies virus neutralizing antibodies for more than three decades. In the late 1970s, ELISA began to be used to estimate the level of rabies virus antibody and has recently been used by some laboratories as an alternate screening test for animal sera. Although the ELISA appears simpler, safer and more efficient, the assay is less sensitive in detecting low values of rabies virus neutralizing antibodies than neutralization tests. This study was designed to evaluate a new ELISA-based method for detecting rabies virus binding antibody. This new technique uses electro-chemi-luminescence labels and carbon electrode plates to detect binding events. In this comparative study, the RFFIT and the new ELISA-based technique were used to evaluate the level of rabies virus antibodies in human and animal serum samples. By using a conservative approximation of 0.15 IU/ml as a cutoff point, the new ELISA-based technique demonstrated a sensitivity of 100% and a specificity of 95% for human samples and for experimental animal samples. The sensitivity and specificity for field animal samples was 96% and 95%, respectively. The preliminary results from this study appear promising and demonstrate a higher sensitivity than traditional ELISA methods. Published by Elsevier Ltd.

  10. 11th GCC Closed Forum: cumulative stability; matrix stability; immunogenicity assays; laboratory manuals; biosimilars; chiral methods; hybrid LBA/LCMS assays; fit-for-purpose validation; China Food and Drug Administration bioanalytical method validation.

    PubMed

    Islam, Rafiq; Briscoe, Chad; Bower, Joseph; Cape, Stephanie; Arnold, Mark; Hayes, Roger; Warren, Mark; Karnik, Shane; Stouffer, Bruce; Xiao, Yi Qun; van der Strate, Barry; Sikkema, Daniel; Fang, Xinping; Tudoroniu, Ariana; Tayyem, Rabab; Brant, Ashley; Spriggs, Franklin; Barry, Colin; Khan, Masood; Keyhani, Anahita; Zimmer, Jennifer; Caturla, Maria Cruz; Couerbe, Philippe; Khadang, Ardeshir; Bourdage, James; Datin, Jim; Zemo, Jennifer; Hughes, Nicola; Fatmi, Saadya; Sheldon, Curtis; Fountain, Scott; Satterwhite, Christina; Colletti, Kelly; Vija, Jenifer; Yu, Mathilde; Stamatopoulos, John; Lin, Jenny; Wilfahrt, Jim; Dinan, Andrew; Ohorodnik, Susan; Hulse, James; Patel, Vimal; Garofolo, Wei; Savoie, Natasha; Brown, Michael; Papac, Damon; Buonarati, Mike; Hristopoulos, George; Beaver, Chris; Boudreau, Nadine; Williard, Clark; Liu, Yansheng; Ray, Gene; Warrino, Dominic; Xu, Allan; Green, Rachel; Hayward-Sewell, Joanne; Marcelletti, John; Sanchez, Christina; Kennedy, Michael; Charles, Jessica St; Bouhajib, Mohammed; Nehls, Corey; Tabler, Edward; Tu, Jing; Joyce, Philip; Iordachescu, Adriana; DuBey, Ira; Lindsay, John; Yamashita, Jim; Wells, Edward

    2018-04-01

    The 11th Global CRO Council Closed Forum was held in Universal City, CA, USA on 3 April 2017. Representatives from international CRO members offering bioanalytical services were in attendance in order to discuss scientific and regulatory issues specific to bioanalysis. The second CRO-Pharma Scientific Interchange Meeting was held on 7 April 2017, which included Pharma representatives' sharing perspectives on the topics discussed earlier in the week with the CRO members. The issues discussed at the meetings included cumulative stability evaluations, matrix stability evaluations, the 2016 US FDA Immunogenicity Guidance and recent and unexpected FDA Form 483s on immunogenicity assays, the bioanalytical laboratory's role in writing PK sample collection instructions, biosimilars, CRO perspectives on the use of chiral versus achiral methods, hybrid LBA/LCMS assays, applications of fit-for-purpose validation and, at the Global CRO Council Closed Forum only, the status and trend of current regulated bioanalytical practice in China under CFDA's new BMV policy. Conclusions from discussions of these topics at both meetings are included in this report.

  11. Assessment of amphotericin B susceptibility in Leishmania infantum promastigotes by flow cytometric membrane potential assay.

    PubMed

    Azas, N; Di Giorgio, C; Delmas, F; Gasquet, M; Timon-David, P

    1997-06-01

    Flow cytometry was used for measuring the effects of amphotericin B on the membrane of Leishmania infantum strains. The technique was adapted from the rapid flow cytometric membrane potential assay developed by Ordonez and Wehman (Cytometry 22:154-157, 1995) for evaluating antibiotic-susceptibility of Candida species. The study consisted of measuring membrane potential changes induced by amphotericin B in 3 initial strains and 12 laboratory-generated variants adapted to grow with amphotericin B. Results showed that, after 3 h of incubation, amphotericin B induced a dose-related decrease of membrane potential that reached its maximal level at the same concentrations that inhibited parasite growth. These results suggest that the flow cytometric membrane potential assay could be used to assess the susceptibility of Leishmania promastigotes to amphotericin B.

  12. Development and Validation of a Laboratory-Developed Multiplex Real-Time PCR Assay on the BD Max System for Detection of Herpes Simplex Virus and Varicella-Zoster Virus DNA in Various Clinical Specimens.

    PubMed

    Pillet, Sylvie; Verhoeven, Paul O; Epercieux, Amélie; Bourlet, Thomas; Pozzetto, Bruno

    2015-06-01

    A multiplex real-time PCR (quantitative PCR [qPCR]) assay detecting herpes simplex virus (HSV) and varicella-zoster virus (VZV) DNA together with an internal control was developed on the BD Max platform combining automated DNA extraction and an open amplification procedure. Its performance was compared to those of PCR assays routinely used in the laboratory, namely, a laboratory-developed test for HSV DNA on the LightCycler instrument and a test using a commercial master mix for VZV DNA on the ABI7500fast system. Using a pool of negative cerebrospinal fluid (CSF) samples spiked with either calibrated controls for HSV-1 and VZV or dilutions of a clinical strain that was previously quantified for HSV-2, the empirical limit of detection of the BD Max assay was 195.65, 91.80, and 414.07 copies/ml for HSV-1, HSV-2, and VZV, respectively. All the samples from HSV and VZV DNA quality control panels (Quality Control for Molecular Diagnostics [QCMD], 2013, Glasgow, United Kingdom) were correctly identified by the BD Max assay. From 180 clinical specimens of various origins, 2 CSF samples were found invalid by the BD Max assay due to the absence of detection of the internal control; a concordance of 100% was observed between the BD Max assay and the corresponding routine tests. The BD Max assay detected the PCR signal 3 to 4 cycles earlier than did the routine methods. With results available within 2 h on a wide range of specimens, this sensitive and fully automated PCR assay exhibited the qualities required for detecting simultaneously HSV and VZV DNA on a routine basis. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  13. Evaluation of the BYG Carba Test, a New Electrochemical Assay for Rapid Laboratory Detection of Carbapenemase-Producing Enterobacteriaceae

    PubMed Central

    Yunus, Sami; Massart, Marion; Huang, Te-Din; Glupczynski, Youri

    2015-01-01

    Accurate detection of carbapenemase-producing Enterobacteriaceae (CPE) constitutes a major laboratory diagnostic challenge. We evaluated an electrochemical technique (the BYG Carba test) which allows detection of CPE in less than 35 min. The BYG Carba test was first validated in triplicate against 57 collection isolates with previously characterized β-lactam resistance mechanisms (OXA-48, n = 12; KPC, n = 8; NDM, n = 8; VIM, n = 8; IMP, n = 3; GIM, n = 1; GES-6, n = 1; no carbapenemase, n = 16) and against a panel of 10 isolates obtained from the United Kingdom National External Quality Assessment Service (NEQAS). The test was then evaluated prospectively against 324 isolates referred to the national reference center for suspicion of CPE. The BYG Carba test results were compared with those obtained with the Carba NP test using multiplex PCR sequencing as the gold standard. Of the 57 collection and the 10 NEQAS isolates, all but one GES-6-producing isolate were correctly identified by the Carba BYG test. Among the 324 consecutive Enterobacteriaceae isolates tested prospectively, 146 were confirmed as noncarbapenemase producers by PCR while 178 harbored a carbapenemase gene (OXA-48, n = 117; KPC, n = 25; NDM, n = 23; and VIM, n = 13). Prospectively, in comparison with PCR results, the BYG Carba test displayed 95% sensitivity and 100% specificity versus 89% and 100%, respectively, for the Carba NP test. The BYG Carba test is a novel, rapid, and efficient assay based on an electro-active polymer biosensing technology discriminating between CPE and non-CPE. The precise electrochemical signal (electrochemical impedance variations) allows the establishment of real-time objective measurement and interpretation criteria which should facilitate the accreditation process of this technology. PMID:26637378

  14. Web-based scoring of the dicentric assay, a collaborative biodosimetric scoring strategy for population triage in large scale radiation accidents.

    PubMed

    Romm, H; Ainsbury, E; Bajinskis, A; Barnard, S; Barquinero, J F; Barrios, L; Beinke, C; Puig-Casanovas, R; Deperas-Kaminska, M; Gregoire, E; Oestreicher, U; Lindholm, C; Moquet, J; Rothkamm, K; Sommer, S; Thierens, H; Vral, A; Vandersickel, V; Wojcik, A

    2014-05-01

    In the case of a large scale radiation accident high throughput methods of biological dosimetry for population triage are needed to identify individuals requiring clinical treatment. The dicentric assay performed in web-based scoring mode may be a very suitable technique. Within the MULTIBIODOSE EU FP7 project a network is being established of 8 laboratories with expertise in dose estimations based on the dicentric assay. Here, the manual dicentric assay was tested in a web-based scoring mode. More than 23,000 high resolution images of metaphase spreads (only first mitosis) were captured by four laboratories and established as image galleries on the internet (cloud). The galleries included images of a complete dose effect curve (0-5.0 Gy) and three types of irradiation scenarios simulating acute whole body, partial body and protracted exposure. The blood samples had been irradiated in vitro with gamma rays at the University of Ghent, Belgium. Two laboratories provided image galleries from Fluorescence plus Giemsa stained slides (3 h colcemid) and the image galleries from the other two laboratories contained images from Giemsa stained preparations (24 h colcemid). Each of the 8 participating laboratories analysed 3 dose points of the dose effect curve (scoring 100 cells for each point) and 3 unknown dose points (50 cells) for each of the 3 simulated irradiation scenarios. At first all analyses were performed in a QuickScan Mode without scoring individual chromosomes, followed by conventional scoring (only complete cells, 46 centromeres). The calibration curves obtained using these two scoring methods were very similar, with no significant difference in the linear-quadratic curve coefficients. Analysis of variance showed a significant effect of dose on the yield of dicentrics, but no significant effect of the laboratories, different methods of slide preparation or different incubation times used for colcemid. The results obtained to date within the MULTIBIODOSE

  15. Laboratory compliance with the American Society of Clinical Oncology/college of American Pathologists guidelines for human epidermal growth factor receptor 2 testing: a College of American Pathologists survey of 757 laboratories.

    PubMed

    Nakhleh, Raouf E; Grimm, Erin E; Idowu, Michael O; Souers, Rhona J; Fitzgibbons, Patrick L

    2010-05-01

    To ensure quality human epidermal growth receptor 2 (HER2) testing in breast cancer, the American Society of Clinical Oncology/College of American Pathologists guidelines were introduced with expected compliance by 2008. To assess the effect these guidelines have had on pathology laboratories and their ability to address key components. In late 2008, a survey was distributed with the HER2 immunohistochemistry (IHC) proficiency testing program. It included questions regarding pathology practice characteristics and assay validation using fluorescence in situ hybridization or another IHC laboratory assay and assessed pathologist HER2 scoring competency. Of the 907 surveys sent, 757 (83.5%) were returned. The median laboratory accessioned 15 000 cases and performed 190 HER2 tests annually. Quantitative computer image analysis was used by 33% of laboratories. In-house fluorescence in situ hybridization was performed in 23% of laboratories, and 60% of laboratories addressed the 6- to 48-hour tissue fixation requirement by embedding tissue on the weekend. HER2 testing was performed on the initial biopsy in 40%, on the resection specimen in 6%, and on either in 56% of laboratories. Testing was validated with only fluorescence in situ hybridization in 47% of laboratories, whereas 10% of laboratories used another IHC assay only; 13% used both assays, and 12% and 15% of laboratories had not validated their assays or chose "not applicable" on the survey question, respectively. The 90% concordance rate with fluorescence in situ hybridization results was achieved by 88% of laboratories for IHC-negative findings and by 81% of laboratories for IHC-positive cases. The 90% concordance rate for laboratories using another IHC assay was achieved by 80% for negative findings and 75% for positive cases. About 91% of laboratories had a pathologist competency assessment program. This survey demonstrates the extent and characteristics of HER2 testing. Although some American Society of

  16. Radon assay and purification techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simgen, Hardy

    Radon is a source of background in many astroparticle physics experiments searching for rare low energy events. In this paper an overview about radon in the field is given including radon detection techniques, radon sources and material screening with respect to radon emanation. Finally, also the problem of long-lived radioactive {sup 222}Rn-daughters and the question of gas purification from radon is addressed.

  17. Radon assay and purification techniques

    NASA Astrophysics Data System (ADS)

    Simgen, Hardy

    2013-08-01

    Radon is a source of background in many astroparticle physics experiments searching for rare low energy events. In this paper an overview about radon in the field is given including radon detection techniques, radon sources and material screening with respect to radon emanation. Finally, also the problem of long-lived radioactive 222Rn-daughters and the question of gas purification from radon is addressed.

  18. Laboratory Validation of the Sand Fly Fever Virus Antigen Assay

    DTIC Science & Technology

    2015-12-01

    several commercially available assays from VecTOR Test Systems Inc. for malaria, West Nile virus, Rift Valley fever virus, dengue , chikungunya, and...Sabin AB. 1955. Recent advances in our knowledge of dengue and sandfly fever. Am J Trop Med Hyg 4:198–207. Sather GE. 1970. Catalogue of arthropod

  19. Preparation, Imaging, and Quantification of Bacterial Surface Motility Assays

    PubMed Central

    Morales-Soto, Nydia; Anyan, Morgen E.; Mattingly, Anne E.; Madukoma, Chinedu S.; Harvey, Cameron W.; Alber, Mark; Déziel, Eric; Kearns, Daniel B.; Shrout, Joshua D.

    2015-01-01

    Bacterial surface motility, such as swarming, is commonly examined in the laboratory using plate assays that necessitate specific concentrations of agar and sometimes inclusion of specific nutrients in the growth medium. The preparation of such explicit media and surface growth conditions serves to provide the favorable conditions that allow not just bacterial growth but coordinated motility of bacteria over these surfaces within thin liquid films. Reproducibility of swarm plate and other surface motility plate assays can be a major challenge. Especially for more “temperate swarmers” that exhibit motility only within agar ranges of 0.4%-0.8% (wt/vol), minor changes in protocol or laboratory environment can greatly influence swarm assay results. “Wettability”, or water content at the liquid-solid-air interface of these plate assays, is often a key variable to be controlled. An additional challenge in assessing swarming is how to quantify observed differences between any two (or more) experiments. Here we detail a versatile two-phase protocol to prepare and image swarm assays. We include guidelines to circumvent the challenges commonly associated with swarm assay media preparation and quantification of data from these assays. We specifically demonstrate our method using bacteria that express fluorescent or bioluminescent genetic reporters like green fluorescent protein (GFP), luciferase (lux operon), or cellular stains to enable time-lapse optical imaging. We further demonstrate the ability of our method to track competing swarming species in the same experiment. PMID:25938934

  20. Assay optimisation and technology transfer for multi-site immuno-monitoring in vaccine trials

    PubMed Central

    Harris, Stephanie A.; Satti, Iman; Bryan, Donna; Walker, K. Barry; Dockrell, Hazel M.; McShane, Helen; Ho, Mei Mei

    2017-01-01

    Cellular immunological assays are important tools for the monitoring of responses to T-cell-inducing vaccine candidates. As these bioassays are often technically complex and require considerable experience, careful technology transfer between laboratories is critical if high quality, reproducible data that allows comparison between sites, is to be generated. The aim of this study, funded by the European Union Framework Program 7-funded TRANSVAC project, was to optimise Standard Operating Procedures and the technology transfer process to maximise the reproducibility of three bioassays for interferon-gamma responses: enzyme-linked immunosorbent assay (ELISA), ex-vivo enzyme-linked immunospot and intracellular cytokine staining. We found that the initial variability in results generated across three different laboratories reduced following a combination of Standard Operating Procedure harmonisation and the undertaking of side-by-side training sessions in which assay operators performed each assay in the presence of an assay ‘lead’ operator. Mean inter-site coefficients of variance reduced following this training session when compared with the pre-training values, most notably for the ELISA assay. There was a trend for increased inter-site variability at lower response magnitudes for the ELISA and intracellular cytokine staining assays. In conclusion, we recommend that on-site operator training is an essential component of the assay technology transfer process and combined with harmonised Standard Operating Procedures will improve the quality, reproducibility and comparability of data produced across different laboratories. These data may be helpful in ongoing discussions of the potential risk/benefit of centralised immunological assay strategies for large clinical trials versus decentralised units. PMID:29020010

  1. Enzyme-Linked Antibodies: A Laboratory Introduction to the ELISA Assay

    NASA Astrophysics Data System (ADS)

    Anderson, Gretchen L.; McNellis, Leo A.

    1998-10-01

    A fast and economical laboratory exercise is presented that qualitatively demonstrates the power of enzyme-linked antibodies to detect a specific antigen. Although ELISAs are commonly used in disease diagnosis in clinical settings, this application uses biotin, covalently attached to albumin, to take advantage of readily available reagents and avoids problems associated with potentially pathogenic antigens. The laboratory exercise is suitable for high school or freshman level biochemistry courses, and can be completed within two hours.

  2. A comparison of two colorimetric assays, based upon Lowry and Bradford techniques, to estimate total protein in soil extracts.

    PubMed

    Redmile-Gordon, M A; Armenise, E; White, R P; Hirsch, P R; Goulding, K W T

    2013-12-01

    Soil extracts usually contain large quantities of dissolved humified organic material, typically reflected by high polyphenolic content. Since polyphenols seriously confound quantification of extracted protein, minimising this interference is important to ensure measurements are representative. Although the Bradford colorimetric assay is used routinely in soil science for rapid quantification protein in soil-extracts, it has several limitations. We therefore investigated an alternative colorimetric technique based on the Lowry assay (frequently used to measure protein and humic substances as distinct pools in microbial biofilms). The accuracies of both the Bradford assay and a modified Lowry microplate method were compared in factorial combination. Protein was quantified in soil-extracts (extracted with citrate), including standard additions of model protein (BSA) and polyphenol (Sigma H1675-2). Using the Lowry microplate assay described, no interfering effects of citrate were detected even with concentrations up to 5 times greater than are typically used to extract soil protein. Moreover, the Bradford assay was found to be highly susceptible to two simultaneous and confounding artefacts: 1) the colour development due to added protein was greatly inhibited by polyphenol concentration, and 2) substantial colour development was caused directly by the polyphenol addition. In contrast, the Lowry method enabled distinction between colour development from protein and non-protein origin, providing a more accurate quantitative analysis. These results suggest that the modified-Lowry method is a more suitable measure of extract protein (defined by standard equivalents) because it is less confounded by the high polyphenolic content which is so typical of soil extracts.

  3. Validation of Immunohistochemical Assays for Integral Biomarkers in the NCI-MATCH EAY131 Clinical Trial.

    PubMed

    Khoury, Joseph D; Wang, Wei-Lien; Prieto, Victor G; Medeiros, L Jeffrey; Kalhor, Neda; Hameed, Meera; Broaddus, Russell; Hamilton, Stanley R

    2018-02-01

    Biomarkers that guide therapy selection are gaining unprecedented importance as targeted therapy options increase in scope and complexity. In conjunction with high-throughput molecular techniques, therapy-guiding biomarker assays based upon immunohistochemistry (IHC) have a critical role in cancer care in that they inform about the expression status of a protein target. Here, we describe the validation procedures for four clinical IHC biomarker assays-PTEN, RB, MLH1, and MSH2-for use as integral biomarkers in the nationwide NCI-Molecular Analysis for Therapy Choice (NCI-MATCH) EAY131 clinical trial. Validation procedures were developed through an iterative process based on collective experience and adaptation of broad guidelines from the FDA. The steps included primary antibody selection; assay optimization; development of assay interpretation criteria incorporating biological considerations; and expected staining patterns, including indeterminate results, orthogonal validation, and tissue validation. Following assay lockdown, patient samples and cell lines were used for analytic and clinical validation. The assays were then approved as laboratory-developed tests and used for clinical trial decisions for treatment selection. Calculations of sensitivity and specificity were undertaken using various definitions of gold-standard references, and external validation was required for the PTEN IHC assay. In conclusion, validation of IHC biomarker assays critical for guiding therapy in clinical trials is feasible using comprehensive preanalytic, analytic, and postanalytic steps. Implementation of standardized guidelines provides a useful framework for validating IHC biomarker assays that allow for reproducibility across institutions for routine clinical use. Clin Cancer Res; 24(3); 521-31. ©2017 AACR . ©2017 American Association for Cancer Research.

  4. Automation of the ELISpot assay for high-throughput detection of antigen-specific T-cell responses.

    PubMed

    Almeida, Coral-Ann M; Roberts, Steven G; Laird, Rebecca; McKinnon, Elizabeth; Ahmed, Imran; Pfafferott, Katja; Turley, Joanne; Keane, Niamh M; Lucas, Andrew; Rushton, Ben; Chopra, Abha; Mallal, Simon; John, Mina

    2009-05-15

    The enzyme linked immunospot (ELISpot) assay is a fundamental tool in cellular immunology, providing both quantitative and qualitative information on cellular cytokine responses to defined antigens. It enables the comprehensive screening of patient derived peripheral blood mononuclear cells to reveal the antigenic restriction of T-cell responses and is an emerging technique in clinical laboratory investigation of certain infectious diseases. As with all cellular-based assays, the final results of the assay are dependent on a number of technical variables that may impact precision if not highly standardised between operators. When studies that are large scale or using multiple antigens are set up manually, these assays may be labour intensive, have many manual handling steps, are subject to data and sample integrity failure and may show large inter-operator variability. Here we describe the successful automated performance of the interferon (IFN)-gamma ELISpot assay from cell counting through to electronic capture of cytokine quantitation and present the results of a comparison between automated and manual performance of the ELISpot assay. The mean number of spot forming units enumerated by both methods for limiting dilutions of CMV, EBV and influenza (CEF)-derived peptides in six healthy individuals were highly correlated (r>0.83, p<0.05). The precision results from the automated system compared favourably with the manual ELISpot and further ensured electronic tracking, increased through-put and reduced turnaround time.

  5. A magnetic bead-based ligand binding assay to facilitate human kynurenine 3-monooxygenase drug discovery.

    PubMed

    Wilson, Kris; Mole, Damian J; Homer, Natalie Z M; Iredale, John P; Auer, Manfred; Webster, Scott P

    2015-02-01

    Human kynurenine 3-monooxygenase (KMO) is emerging as an important drug target enzyme in a number of inflammatory and neurodegenerative disease states. Recombinant protein production of KMO, and therefore discovery of KMO ligands, is challenging due to a large membrane targeting domain at the C-terminus of the enzyme that causes stability, solubility, and purification difficulties. The purpose of our investigation was to develop a suitable screening method for targeting human KMO and other similarly challenging drug targets. Here, we report the development of a magnetic bead-based binding assay using mass spectrometry detection for human KMO protein. The assay incorporates isolation of FLAG-tagged KMO enzyme on protein A magnetic beads. The protein-bound beads are incubated with potential binding compounds before specific cleavage of the protein-compound complexes from the beads. Mass spectrometry analysis is used to identify the compounds that demonstrate specific binding affinity for the target protein. The technique was validated using known inhibitors of KMO. This assay is a robust alternative to traditional ligand-binding assays for challenging protein targets, and it overcomes specific difficulties associated with isolating human KMO. © 2014 Society for Laboratory Automation and Screening.

  6. Development and implementation of an international proficiency testing program for a neutralizing antibody assay for HIV-1 in TZM-bl cells.

    PubMed

    Todd, Christopher A; Greene, Kelli M; Yu, Xuesong; Ozaki, Daniel A; Gao, Hongmei; Huang, Yunda; Wang, Maggie; Li, Gary; Brown, Ronald; Wood, Blake; D'Souza, M Patricia; Gilbert, Peter; Montefiori, David C; Sarzotti-Kelsoe, Marcella

    2012-01-31

    Recent advances in assay technology have led to major improvements in how HIV-1 neutralizing antibodies are measured. A luciferase reporter gene assay performed in TZM-bl (JC53bl-13) cells has been optimized and validated. Because this assay has been adopted by multiple laboratories worldwide, an external proficiency testing program was developed to ensure data equivalency across laboratories performing this neutralizing antibody assay for HIV/AIDS vaccine clinical trials. The program was optimized by conducting three independent rounds of testing, with an increased level of stringency from the first to third round. Results from the participating domestic and international laboratories improved each round as factors that contributed to inter-assay variability were identified and minimized. Key contributors to increased agreement were experience among laboratories and standardization of reagents. A statistical qualification rule was developed using a simulation procedure based on the three optimization rounds of testing, where a laboratory qualifies if at least 25 of the 30 ID50 values lie within the acceptance ranges. This ensures no more than a 20% risk that a participating laboratory fails to qualify when it should, as defined by the simulation procedure. Five experienced reference laboratories were identified and tested a series of standardized reagents to derive the acceptance ranges for pass-fail criteria. This Standardized Proficiency Testing Program is the first available for the evaluation and documentation of assay equivalency for laboratories performing HIV-1 neutralizing antibody assays and may provide guidance for the development of future proficiency testing programs for other assay platforms. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Clonogenic assay: adherent cells.

    PubMed

    Rafehi, Haloom; Orlowski, Christian; Georgiadis, George T; Ververis, Katherine; El-Osta, Assam; Karagiannis, Tom C

    2011-03-13

    The clonogenic (or colony forming) assay has been established for more than 50 years; the original paper describing the technique was published in 1956. Apart from documenting the method, the initial landmark study generated the first radiation-dose response curve for X-ray irradiated mammalian (HeLa) cells in culture. Basically, the clonogenic assay enables an assessment of the differences in reproductive viability (capacity of cells to produce progeny; i.e. a single cell to form a colony of 50 or more cells) between control untreated cells and cells that have undergone various treatments such as exposure to ionising radiation, various chemical compounds (e.g. cytotoxic agents) or in other cases genetic manipulation. The assay has become the most widely accepted technique in radiation biology and has been widely used for evaluating the radiation sensitivity of different cell lines. Further, the clonogenic assay is commonly used for monitoring the efficacy of radiation modifying compounds and for determining the effects of cytotoxic agents and other anti-cancer therapeutics on colony forming ability, in different cell lines. A typical clonogenic survival experiment using adherent cells lines involves three distinct components, 1) treatment of the cell monolayer in tissue culture flasks, 2) preparation of single cell suspensions and plating an appropriate number of cells in petri dishes and 3) fixing and staining colonies following a relevant incubation period, which could range from 1-3 weeks, depending on the cell line. Here we demonstrate the general procedure for performing the clonogenic assay with adherent cell lines with the use of an immortalized human keratinocyte cell line (FEP-1811). Also, our aims are to describe common features of clonogenic assays including calculation of the plating efficiency and survival fractions after exposure of cells to radiation, and to exemplify modification of radiation-response with the use of a natural antioxidant

  8. Clonogenic Assay: Adherent Cells

    PubMed Central

    Rafehi, Haloom; Orlowski, Christian; Georgiadis, George T.; Ververis, Katherine; El-Osta, Assam; Karagiannis, Tom C.

    2011-01-01

    The clonogenic (or colony forming) assay has been established for more than 50 years; the original paper describing the technique was published in 19561. Apart from documenting the method, the initial landmark study generated the first radiation-dose response curve for X-ray irradiated mammalian (HeLa) cells in culture1. Basically, the clonogenic assay enables an assessment of the differences in reproductive viability (capacity of cells to produce progeny; i.e. a single cell to form a colony of 50 or more cells) between control untreated cells and cells that have undergone various treatments such as exposure to ionising radiation, various chemical compounds (e.g. cytotoxic agents) or in other cases genetic manipulation. The assay has become the most widely accepted technique in radiation biology and has been widely used for evaluating the radiation sensitivity of different cell lines. Further, the clonogenic assay is commonly used for monitoring the efficacy of radiation modifying compounds and for determining the effects of cytotoxic agents and other anti-cancer therapeutics on colony forming ability, in different cell lines. A typical clonogenic survival experiment using adherent cells lines involves three distinct components, 1) treatment of the cell monolayer in tissue culture flasks, 2) preparation of single cell suspensions and plating an appropriate number of cells in petri dishes and 3) fixing and staining colonies following a relevant incubation period, which could range from 1-3 weeks, depending on the cell line. Here we demonstrate the general procedure for performing the clonogenic assay with adherent cell lines with the use of an immortalized human keratinocyte cell line (FEP-1811)2. Also, our aims are to describe common features of clonogenic assays including calculation of the plating efficiency and survival fractions after exposure of cells to radiation, and to exemplify modification of radiation-response with the use of a natural antioxidant

  9. The Pitfalls of Companion Diagnostics: Evaluation of Discordant EGFR Mutation Results from a Clinical Laboratory and a Central Laboratory.

    PubMed

    Turner, Scott A; Peterson, Jason D; Pettus, Jason R; de Abreu, Francine B; Amos, Christopher I; Dragnev, Konstantin H; Tsongalis, Gregory J

    2016-05-01

    Accurate identification of somatic mutations in formalin-fixed, paraffin-embedded tumor tissue is required for enrollment into clinical trials for many novel targeted therapeutics, including trials requiring EGFR mutation status in non-small-cell lung carcinomas. Central clinical trial laboratories contracted to perform this analysis typically rely on US Food and Drug Administration-approved targeted assays to identify these mutations. We present two cases in which central laboratories inaccurately reported EGFR mutation status because of improper identification and isolation of tumor material and failure to accurately report assay limitations, resulting in enrollment denial. Such cases highlight the need for increased awareness by clinical trials of the limitation of these US Food and Drug Administration-approved assays and the necessity for a mechanism to reevaluate discordant results by alternative laboratory-developed procedures, including clinical next-generation sequencing. Copyright © 2016 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  10. Application of the One-Minute Preceptor Technique by Novice Teachers in the Gross Anatomy Laboratory

    ERIC Educational Resources Information Center

    Chan, Lap Ki; Yang, Jian; Irby, David M.

    2015-01-01

    The one-minute preceptor (OMP) was originally developed in the ambulatory care setting as a time-efficient teaching technique for learner-centered clinical training. There are also possible advantages of using the OMP in the gross anatomy laboratory. However, in a previous study it was found that providing training to experienced gross anatomy…

  11. Bioanalytical method transfer considerations of chromatographic-based assays.

    PubMed

    Williard, Clark V

    2016-07-01

    Bioanalysis is an important part of the modern drug development process. The business practice of outsourcing and transferring bioanalytical methods from laboratory to laboratory has increasingly become a crucial strategy for successful and efficient delivery of therapies to the market. This chapter discusses important considerations when transferring various types of chromatographic-based assays in today's pharmaceutical research and development environment.

  12. A laboratory demonstration of high-resolution hard X-ray and gamma-ray imaging using Fourier-transform techniques

    NASA Technical Reports Server (NTRS)

    Palmer, David; Prince, Thomas A.

    1987-01-01

    A laboratory imaging system has been developed to study the use of Fourier-transform techniques in high-resolution hard X-ray and gamma-ray imaging, with particular emphasis on possible applications to high-energy astronomy. Considerations for the design of a Fourier-transform imager and the instrumentation used in the laboratory studies is described. Several analysis methods for image reconstruction are discussed including the CLEAN algorithm and maximum entropy methods. Images obtained using these methods are presented.

  13. HIGHLY SENSITIVE ASSAY FOR ANTICHOLINESTERASE COMPOUNDS USING 96 WELL PLATE FORMAT

    EPA Science Inventory

    The rapid and sensitive detection of organophosphate insecticides using a 96 well plate format is reported. Several features of this assay make it attractive for development as a laboratory-based or field screening assay. Acetylcholinesterase (AChE) was stabilized in a gelati...

  14. An European inter-laboratory validation of alternative endpoints of the murine local lymph node assay: first round.

    PubMed

    Ehling, G; Hecht, M; Heusener, A; Huesler, J; Gamer, A O; van Loveren, H; Maurer, Th; Riecke, K; Ullmann, L; Ulrich, P; Vandebriel, R; Vohr, H-W

    2005-08-15

    The new OECD guideline 429 (skin sensitization: local lymph node assay) is based upon a protocol, which utilises the incorporation of radioactivity into DNA as a measure for cell proliferation in vivo. The guideline also enables the use of alternative endpoints in order to assess draining lymph node (LN) cell proliferation. Here we describe the first round of an inter-laboratory validation of alternative endpoints in the LLNA conducted in seven laboratories. The validation study was managed and supervised by the Swiss Agency for Therapeutic Products, Swissmedic. Statistical analyses of all data were performed by an independent centre at the University of Bern, Department of Statistics. Ear-draining, LN weight and cell count were used to assess proliferation instead of radioactive labeling of lymph node cells. In addition, the acute inflammatory skin reaction was measured by ear swelling and weight of circular biopsies of the ears to identify skin irritating properties of the test items. Hexylcinnamaldehyde (HCA) and three blinded test items were applied to female, 8--10 weeks old NMRI and BALB/c mice. Results were sent via the independent study coordinator to the statistician. The results of this first round showed that the alternative endpoints of the LLNA are sensitive and robust parameters. The use of ear weights added an important parameter assessing the skin irritation potential, which supports the differentiation of pure irritative from contact allergenic potential. There were absolute no discrepancies between the categorisation of the three test substances A--C determined by each single participating laboratories. The results highlighted also that many parameters do have an impact on the strength of the responses. Therefore, such parameters have to be taken into consideration for the categorisation of compounds due to their relative sensitizing potencies.

  15. Quantitative comparison of DNA methylation assays for biomarker development and clinical applications.

    PubMed

    2016-07-01

    DNA methylation patterns are altered in numerous diseases and often correlate with clinically relevant information such as disease subtypes, prognosis and drug response. With suitable assays and after validation in large cohorts, such associations can be exploited for clinical diagnostics and personalized treatment decisions. Here we describe the results of a community-wide benchmarking study comparing the performance of all widely used methods for DNA methylation analysis that are compatible with routine clinical use. We shipped 32 reference samples to 18 laboratories in seven different countries. Researchers in those laboratories collectively contributed 21 locus-specific assays for an average of 27 predefined genomic regions, as well as six global assays. We evaluated assay sensitivity on low-input samples and assessed the assays' ability to discriminate between cell types. Good agreement was observed across all tested methods, with amplicon bisulfite sequencing and bisulfite pyrosequencing showing the best all-round performance. Our technology comparison can inform the selection, optimization and use of DNA methylation assays in large-scale validation studies, biomarker development and clinical diagnostics.

  16. Ivory species identification using electrophoresis-based techniques.

    PubMed

    Kitpipit, Thitika; Thanakiatkrai, Phuvadol; Penchart, Kitichaya; Ouithavon, Kanita; Satasook, Chutamas; Linacre, Adrian

    2016-12-01

    Despite continuous conservation efforts by national and international organizations, the populations of the three extant elephant species are still dramatically declining due to the illegal trade in ivory leading to the killing of elephants. A requirement to aid investigations and prosecutions is the accurate identification of the elephant species from which the ivory was removed. We report on the development of the first fully validated multiplex PCR-electrophoresis assay for ivory DNA analysis that can be used as a screening or confirmatory test. SNPs from the NADH dehydrogenase 5 and cytochrome b gene loci were identified and used in the development of the assay. The three extant elephant species could be identified based on three peaks/bands. Elephas maximus exhibited two distinct PCR fragments at approximate 129 and 381 bp; Loxodonta cyclotis showed two PCR fragments at 89 and 129 bp; and Loxodonta africana showed a single fragment of 129 bp. The assay correctly identified the elephant species using all 113 ivory and blood samples used in this report. We also report on the high sensitivity and specificity of the assay. All single-blinded samples were correctly classified, which demonstrated the assay's ability to be used for real casework. In addition, the assay could be used in conjunction with the technique of direct amplification. We propose that the test will benefit wildlife forensic laboratories and aid in the transition to the criminal justice system. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Quality Assurance Specifications for Planetary Protection Assays

    NASA Astrophysics Data System (ADS)

    Baker, Amy

    As the European Space Agency planetary protection (PP) activities move forward to support the ExoMars and other planetary missions, it will become necessary to increase staffing of labo-ratories that provide analyses for these programs. Standardization of procedures, a comprehen-sive quality assurance program, and unilateral training of personnel will be necessary to ensure that the planetary protection goals and schedules are met. The PP Quality Assurance/Quality Control (QAQC) program is designed to regulate and monitor procedures performed by labora-tory personnel to ensure that all work meets data quality objectives through the assembly and launch process. Because personnel time is at a premium and sampling schedules are often de-pendent on engineering schedules, it is necessary to have flexible staffing to support all sampling requirements. The most productive approach to having a competent and flexible work force is to establish well defined laboratory procedures and training programs that clearly address the needs of the program and the work force. The quality assurance specification for planetary protection assays has to ensure that labora-tories and associated personnel can demonstrate the competence to perform assays according to the applicable standard AD4. Detailed subjects included in the presentation are as follows: • field and laboratory control criteria • data reporting • personnel training requirements and certification • laboratory audit criteria. Based upon RD2 for primary and secondary validation and RD3 for data quality objectives, the QAQC will provide traceable quality assurance safeguards by providing structured laboratory requirements for guidelines and oversight including training and technical updates, standardized documentation, standardized QA/QC checks, data review and data archiving.

  18. Policies and practices in haemostasis testing among laboratories in Croatia: a survey on behalf of a Working Group for Laboratory Coagulation of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    PubMed

    Bronić, Ana; Herak, Desiree Coen; Margetić, Sandra; Milić, Marija

    2017-02-15

    The objective of this survey was to assess current policies and practice in haemostasis testing among both hospital and outpatient laboratories in Republic of Croatia. A questionnaire with seventy questions divided into nine sections was created in May 2015. Participants were asked about their practice related to test request form, sample collection, prothrombin time (PT) and activated partial thromboplastin time assays, other individual haemostasis assays, point-of-care testing (POCT), reporting of coagulation tests results and quality assurance of procedures, the personnel and other laboratory resources, as well as on issues related to education and implementation of additional coagulation assays in their laboratory. The survey was administered and data were collected between June and September 2015. A total survey response rate was 104/170 (61.2%). Most respondents were faced with incomplete information on prescribed therapy and diagnosis on the test request or inappropriate samples withdrawn on distant locations, but also do not have protocols for handling samples with high haematocrit values. Reporting of PT-INR and D-dimer results was different between laboratories. Although almost all laboratories developed a critical value reporting system, reporting a value to general practitioners is still a problem. Result on coagulation POCT testing showed that not all devices were supervised by laboratories, which is not in compliance with Croatian Chamber of Medical Biochemistry acts. Obtained results highlighted areas that need improvement and different practice patterns in particular field of haemostasis testing among laboratories. A harmonization of the overall process of haemostasis testing at national level should be considered and undertaken.

  19. Temperament in bullheads: do laboratory and field explorative behaviour variables correlate?

    NASA Astrophysics Data System (ADS)

    Kobler, Alexander; Engelen, Brecht; Knaepkens, Guy; Eens, Marcel

    2009-10-01

    The relevance of temperament traits for life history strategy or productivity is increasingly acknowledged. Temperament traits are often either observed in captivity or in the wild, but studies combining both observations are very rare. We examine whether exploratory behaviour in the bullhead ( Cottus perifretum), assayed under laboratory conditions, predicts this behaviour under field conditions. Forty-three PIT-tagged individuals were first assayed for exploration of a novel environment in the aquarium and then released into an unfamiliar stream stretch, where they were later relocated using a mobile antenna. Explorative behaviour assayed in the laboratory was significantly positively related to the exploration in the field, thus predicting distance moved in the field release. Both in the laboratory and in the field, explorative behaviour was not related to individual body length. When bullheads that did not leave the refuge in the aquarium (laboratory assay) and, therefore, did not explore the new environment were excluded from the analysis, the correlation between laboratory and field explorative behaviour variables became weaker. However, overall, our results illustrate that exploration rate of bullheads in isolated single-individual experiments can be used to predict this behaviour in the natural ecosystem.

  20. Accelerated stability assay (ASA) for colloidal systems.

    PubMed

    Chong, Josephine Y T; Mulet, Xavier; Boyd, Ben J; Drummond, Calum J

    2014-05-12

    Assessment of the stability of colloidal systems, in particular lyotropic liquid crystalline dispersions, such as cubosomes and hexosomes, is typically performed qualitatively or with limited throughput on specialized instruments. Here, an accelerated stability assay for colloidal particles has been developed in 384-well plates with standard laboratory equipment. These protocols enable quantitative assessments of colloidal stability. To demonstrate the applicability of the assay, several steric stabilizers for cubic phase nanostructured particles (cubosomes) have been compared to the current "gold standard" Pluronic F127.

  1. FluxCTTX: A LIMS-based tool for management and analysis of cytotoxicity assays data

    PubMed Central

    2015-01-01

    Background Cytotoxicity assays have been used by researchers to screen for cytotoxicity in compound libraries. Researchers can either look for cytotoxic compounds or screen "hits" from initial high-throughput drug screens for unwanted cytotoxic effects before investing in their development as a pharmaceutical. These assays may be used as an alternative to animal experimentation and are becoming increasingly important in modern laboratories. However, the execution of these assays in large scale and different laboratories requires, among other things, the management of protocols, reagents, cell lines used as well as the data produced, which can be a challenge. The management of all this information is greatly improved by the utilization of computational tools to save time and guarantee quality. However, a tool that performs this task designed specifically for cytotoxicity assays is not yet available. Results In this work, we have used a workflow based LIMS -- the Flux system -- and the Together Workflow Editor as a framework to develop FluxCTTX, a tool for management of data from cytotoxicity assays performed at different laboratories. The main work is the development of a workflow, which represents all stages of the assay and has been developed and uploaded in Flux. This workflow models the activities of cytotoxicity assays performed as described in the OECD 129 Guidance Document. Conclusions FluxCTTX presents a solution for the management of the data produced by cytotoxicity assays performed at Interlaboratory comparisons. Its adoption will contribute to guarantee the quality of activities in the process of cytotoxicity tests and enforce the use of Good Laboratory Practices (GLP). Furthermore, the workflow developed is complete and can be adapted to other contexts and different tests for management of other types of data. PMID:26696462

  2. Laboratory assessment of novel oral anticoagulants: method suitability and variability between coagulation laboratories.

    PubMed

    Helin, Tuukka A; Pakkanen, Anja; Lassila, Riitta; Joutsi-Korhonen, Lotta

    2013-05-01

    Laboratory tests to assess novel oral anticoagulants (NOACs) are under evaluation. Routine monitoring is unnecessary, but under special circumstances bioactivity assessment becomes crucial. We analyzed the effects of NOACs on coagulation tests and the availability of specific assays at different laboratories. Plasma samples spiked with dabigatran (Dabi; 120 and 300 μg/L) or rivaroxaban (Riva; 60, 146, and 305 μg/L) were sent to 115 and 38 European laboratories, respectively. International normalized ratio (INR) and activated partial thromboplastin time (APTT) were analyzed for all samples; thrombin time (TT) was analyzed specifically for Dabi and calibrated anti-activated factor X (anti-Xa) activity for Riva. We compared the results with patient samples. Results of Dabi samples were reported by 73 laboratories (13 INR and 9 APTT reagents) and Riva samples by 22 laboratories (5 INR and 4 APTT reagents). Both NOACs increased INR values; the increase was modest, albeit larger, for Dabi, with higher CV, especially with Quick (vs Owren) methods. Both NOACs dose-dependently prolonged the APTT. Again, the prolongation and CVs were larger for Dabi. The INR and APTT results varied reagent-dependently (P < 0.005), with less prolongation in patient samples. TT results (Dabi) and calibrated anti-Xa results (Riva) were reported by only 11 and 8 laboratories, respectively. The screening tests INR and APTT are suboptimal in assessing NOACs, having high reagent dependence and low sensitivity and specificity. They may provide information, if laboratories recognize their limitations. The variation will likely increase and the sensitivity differ in clinical samples. Specific assays measure NOACs accurately; however, few laboratories applied them. © 2013 American Association for Clinical Chemistry.

  3. Applications Where Snap is BPM for Radioactive Waste Assay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, T.J.

    2008-07-01

    Historically, the Atomic Weapons Establishment (AWE) at Aldermaston in the United Kingdom (UK), has used a variety of assay techniques to measure the radioactive content of a diverse range of waste packages from decommissioning, operational and legacy sources. The regulator, the Environment Agency in the UK, places conditions and limits on AWE through an authorisation within the Radioactive Substances Act (RSA93). The conditions and limits require Best Practical Means (BPM) measurements to be used to demonstrate compliance with the authorisation. Hence, the assay technique employed needs to achieve a balance between risk of exposure, environmental considerations, technological considerations, health andmore » safety considerations and cost effectiveness, without being grossly disproportionate in terms of money, time or trouble. Recently published work has concluded that the Spectral Non-destructive Assay Platform (SNAP) assay system is BPM for Depleted Uranium (DU) waste assay at AWE (1) and low level plutonium in soft drummed waste, HEPA filters and soils (2-4). The purpose of this paper is to highlight other applications where SNAP represents BPM for radioactive waste assay. This has been done by intercomparison studies of SNAP with other assay techniques, such as Segmented Gamma Scanner (SGS) and Passive Neutron Coincidence Counter (PNCC). It has been concluded that, for a large range of waste packages encountered at AWE, SNAP is BPM. (author)« less

  4. Transferability and within- and between-laboratory reproducibilities of EpiSensA for predicting skin sensitization potential in vitro: A ring study in three laboratories.

    PubMed

    Mizumachi, Hideyuki; Sakuma, Megumi; Ikezumi, Mayu; Saito, Kazutoshi; Takeyoshi, Midori; Imai, Noriyasu; Okutomi, Hiroko; Umetsu, Asami; Motohashi, Hiroko; Watanabe, Mika; Miyazawa, Masaaki

    2018-05-03

    The epidermal sensitization assay (EpiSensA) is an in vitro skin sensitization test method based on gene expression of four markers related to the induction of skin sensitization; the assay uses commercially available reconstructed human epidermis. EpiSensA has exhibited an accuracy of 90% for 72 chemicals, including lipophilic chemicals and pre-/pro-haptens, when compared with the results of the murine local lymph node assay. In this work, a ring study was performed by one lead and two naive laboratories to evaluate the transferability, as well as within- and between-laboratory reproducibilities, of EpiSensA. Three non-coded chemicals (two lipophilic sensitizers and one non-sensitizer) were tested for the assessment of transferability and 10 coded chemicals (seven sensitizers and three non-sensitizers, including four lipophilic chemicals) were tested for the assessment of reproducibility. In the transferability phase, the non-coded chemicals (two sensitizers and one non-sensitizer) were correctly classified at the two naive laboratories, indicating that the EpiSensA protocol was transferred successfully. For the within-laboratory reproducibility, the data generated with three coded chemicals tested in three independent experiments in each laboratory gave consistent predictions within laboratories. For the between-laboratory reproducibility, 9 of the 10 coded chemicals tested once in each laboratory provided consistent predictions among the three laboratories. These results suggested that EpiSensA has good transferability, as well as within- and between-laboratory reproducibility. Copyright © 2018 John Wiley & Sons, Ltd.

  5. Inter-laboratory validation of the modified murine local lymph node assay based on 5-bromo-2'-deoxyuridine incorporation.

    PubMed

    Kojima, Hajime; Takeyoshi, Masahiro; Sozu, Takashi; Awogi, Takumi; Arima, Kazunori; Idehara, Kenji; Ikarashi, Yoshiaki; Kanazawa, Yukiko; Maki, Eiji; Omori, Takashi; Yuasa, Atsuko; Yoshimura, Isao

    2011-01-01

    The murine local lymph node assay (LLNA) is a well-established alternative to the guinea pig maximization test (GPMT) or Buehler test (BT) for the assessment of the skin sensitizing ability of a drug, cosmetic material, pesticide or industrial chemical. Instead of radioisotope using in this method, Takeyoshi M. et al. (2001) has developed a modified LLNA based on the 5-bromo-2'-deoxyuridine (BrdU) incorporation (LLNA:BrdU-ELISA). The LLNA:BrdU-ELISA is practically identical to the LLNA methodology excluding the use of BrdU, for which a single intraperitoneal injection of BrdU is made on day 4, and colorimetric detection of cell turnover. We conducted the validation study to evaluate the reliability and relevance of LLNA:BrdU-ELISA. The experiment involved 7 laboratories, wherein 10 chemicals were examined under blinded conditions. In this study, 3 chemicals were examined in all laboratories and the remaining 7 were examined in 3 laboratories. The data were expressed as the BrdU incorporation using an ELISA method for each group, and the stimulation index (SI) for each chemical-treated group was determined as the increase in the BrdU incorporation relative to the concurrent vehicle control group. An SI of 2 was set as the cut-off value for exhibiting skin sensitization activity. The results obtained in the experiments conducted for all 10 chemicals were sufficiently consistent with small variations in their SI values. The sensitivity, specificity, and accuracy of LLNA:BrdU-ELISA against those of GPMT/BT were 7/7 (100%), 3/3 (100%), and 10/10 (100%), respectively. Copyright © 2010 John Wiley & Sons, Ltd.

  6. Improvement in laboratory diagnosis of wound botulism and tetanus among injecting illicit-drug users by use of real-time PCR assays for neurotoxin gene fragments.

    PubMed

    Akbulut, D; Grant, K A; McLauchlin, J

    2005-09-01

    An upsurge in wound infections due to Clostridium botulinum and Clostridium tetani among users of illegal injected drugs (IDUs) occurred in the United Kingdom during 2003 and 2004. A real-time PCR assay was developed to detect a fragment of the neurotoxin gene of C. tetani (TeNT) and was used in conjunction with previously described assays for C. botulinum neurotoxin types A, B, and E (BoNTA, -B, and -E). The assays were sensitive, specific, rapid to perform, and applicable to investigating infections among IDUs using DNA extracted directly from wound tissue, as well as bacteria growing among mixed microflora in enrichment cultures and in pure culture on solid media. A combination of bioassay and PCR test results confirmed the clinical diagnosis in 10 of 25 cases of suspected botulism and two of five suspected cases of tetanus among IDUs. The PCR assays were in almost complete agreement with the conventional bioassays when considering results from different samples collected from the same patient. The replacement of bioassays by real-time PCR for the isolation and identification of both C. botulinum and C. tetani demonstrates a sensitivity and specificity similar to those of conventional approaches. However, the real-time PCR assays substantially improves the diagnostic process in terms of the speed of results and by the replacement of experimental animals. Recommendations are given for an improved strategy for the laboratory investigation of suspected wound botulism and tetanus among IDUs.

  7. Clinical performance of the LCx HCV RNA quantitative assay.

    PubMed

    Bertuzis, Rasa; Hardie, Alison; Hottentraeger, Barbara; Izopet, Jacques; Jilg, Wolfgang; Kaesdorf, Barbara; Leckie, Gregor; Leete, Jean; Perrin, Luc; Qiu, Chunfu; Ran, Iris; Schneider, George; Simmonds, Peter; Robinson, John

    2005-02-01

    This study was conducted to assess the performance of the Abbott laboratories LCx HCV RNA Quantitative Assay (LCx assay) in the clinical setting. Four clinical laboratories measured LCx assay precision, specificity, and linearity. In addition, a method comparison was conducted between the LCx assay and the Roche HCV Amplicor Monitor, version 2.0 (Roche Monitor 2.0) and the Bayer VERSANT HCV RNA 3.0 Assay (Bayer bDNA 3.0) quantitative assays. For precision, the observed LCx assay intra-assay standard deviation (S.D.) was 0.060-0.117 log IU/ml, the inter-assay S.D. was 0.083-0.133 log IU/ml, the inter-lot S.D. was 0.105-0.177 log IU/ml, the inter-site S.D. was 0.099-0.190 log IU/ml, and the total S.D. was 0.113-0.190 log IU/ml. The specificity of the LCx assay was 99.4% (542/545; 95% CI, 98.4-99.9%). For linearity, the mean pooled LCx assay results were linear (r=0.994) over the range of the panel (2.54-5.15 log IU/ml). A method comparison demonstrated a correlation coefficient of 0.881 between the LCx assay and Roche Monitor 2.0, 0.872 between the LCx assay and Bayer bDNA 3.0, and 0.870 between Roche Monitor 2.0 and Bayer bDNA 3.0. The mean LCx assay result was 0.04 log IU/ml (95% CI, -0.08, 0.01) lower than the mean Roche Monitor 2.0 result, but 0.57 log IU/ml (95% CI, 0.53, 0.61) higher than the mean Bayer bDNA 3.0 result. The mean Roche Monitor 2.0 result was 0.60 log IU/ml (95% CI, 0.56, 0.65) higher than the mean Bayer bDNA 3.0 result. The LCx assay quantitated genotypes 1-4 with statistical equivalency. The vast majority (98.9%, 278/281) of paired LCx assay-Roche Monitor 2.0 specimen results were within 1 log IU/ml. Similarly, 86.6% (240/277) of paired LCx assay and Bayer bDNA 3.0 specimen results were within 1 log, as were 85.6% (237/277) of paired Roche Monitor 2.0 and Bayer specimen results. These data demonstrate that the LCx assay may be used for quantitation of HCV RNA in HCV-infected individuals.

  8. Benzodiazepine Synthesis and Rapid Toxicity Assay

    ERIC Educational Resources Information Center

    Fletcher, James T.; Boriraj, Grit

    2010-01-01

    A second-year organic chemistry laboratory experiment to introduce students to general concepts of medicinal chemistry is described. Within a single three-hour time window, students experience the synthesis of a biologically active small molecule and the assaying of its biological toxicity. Benzodiazepine rings are commonly found in antidepressant…

  9. Research Techniques Made Simple: Analysis of Collective Cell Migration Using the Wound Healing Assay.

    PubMed

    Grada, Ayman; Otero-Vinas, Marta; Prieto-Castrillo, Francisco; Obagi, Zaidal; Falanga, Vincent

    2017-02-01

    Collective cell migration is a hallmark of wound repair, cancer invasion and metastasis, immune responses, angiogenesis, and embryonic morphogenesis. Wound healing is a complex cellular and biochemical process necessary to restore structurally damaged tissue. It involves dynamic interactions and crosstalk between various cell types, interaction with extracellular matrix molecules, and regulated production of soluble mediators and cytokines. In cutaneous wound healing, skin cells migrate from the wound edges into the wound to restore skin integrity. Analysis of cell migration in vitro is a useful assay to quantify alterations in cell migratory capacity in response to experimental manipulations. Although several methods exist to study cell migration (such as Boyden chamber assay, barrier assays, and microfluidics-based assays), in this short report we will explain the wound healing assay, also known as the "in vitro scratch assay" as a simple, versatile, and cost-effective method to study collective cell migration and wound healing. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  10. A Severe Weather Laboratory Exercise for an Introductory Weather and Climate Class Using Active Learning Techniques

    ERIC Educational Resources Information Center

    Grundstein, Andrew; Durkee, Joshua; Frye, John; Andersen, Theresa; Lieberman, Jordan

    2011-01-01

    This paper describes a new severe weather laboratory exercise for an Introductory Weather and Climate class, appropriate for first and second year college students (including nonscience majors), that incorporates inquiry-based learning techniques. In the lab, students play the role of meteorologists making forecasts for severe weather. The…

  11. Evaluation of the technical performance of novel holotranscobalamin (holoTC) assays in a multicenter European demonstration project.

    PubMed

    Morkbak, Anne L; Heimdal, Randi M; Emmens, Kathleen; Molloy, Anne; Hvas, Anne-Mette; Schneede, Joern; Clarke, Robert; Scott, John M; Ueland, Per M; Nexo, Ebba

    2005-01-01

    A commercially available holotranscobalamin (holo-TC) radioimmunoassay (RIA) (Axis-Shield, Dundee, Scotland) was evaluated in four laboratories and compared with a holoTC ELISA run in one laboratory. The performance of the holoTC RIA assay was comparable in three of the four participating laboratories. The results from these three laboratories, involving at least 20 initial runs of "low", "medium" and "high" serum-based controls (mean holoTC concentrations 34, 60 and 110 pmol/L, respectively) yielded an intra-laboratory imprecision of 6-10%. No systematic inter-laboratory deviations were observed on runs involving 72 patient samples (holoTC concentration range 10-160 pmol/L). A fourth laboratory demonstrated higher assay imprecision for control samples and systematic deviation of results for the patient samples. Measurement of holoTC by ELISA showed an imprecision of 4-5%, and slightly higher mean values for the controls (mean holoTC concentrations 40, 70 and 114 pmol/L, respectively). Comparable results were obtained for the patient samples. The long-term intra-laboratory imprecision was 12% for the holoTC RIA and 6% for the ELISA. In conclusion, it would be prudent to check the calibration and precision prior to starting to use these holoTC assays in research or clinical practice. The results obtained using the holoTC RIA were similar to those obtained using the holoTC ELISA assay.

  12. 21 CFR 225.58 - Laboratory controls.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Laboratory controls. 225.58 Section 225.58 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS... Laboratory controls. (a) The periodic assay of medicated feeds for drug components provides a measure of...

  13. 21 CFR 225.58 - Laboratory controls.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 4 2013-04-01 2013-04-01 false Laboratory controls. 225.58 Section 225.58 Food...: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR MEDICATED FEEDS Product Quality Control § 225.58 Laboratory controls. (a) The periodic assay of medicated feeds for drug components provides a measure of...

  14. 21 CFR 225.58 - Laboratory controls.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 4 2012-04-01 2012-04-01 false Laboratory controls. 225.58 Section 225.58 Food...: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR MEDICATED FEEDS Product Quality Control § 225.58 Laboratory controls. (a) The periodic assay of medicated feeds for drug components provides a measure of...

  15. 21 CFR 225.58 - Laboratory controls.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 4 2011-04-01 2011-04-01 false Laboratory controls. 225.58 Section 225.58 Food...: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR MEDICATED FEEDS Product Quality Control § 225.58 Laboratory controls. (a) The periodic assay of medicated feeds for drug components provides a measure of...

  16. High-Throughput Incubation and Quantification of Agglutination Assays in a Microfluidic System.

    PubMed

    Castro, David; Conchouso, David; Kodzius, Rimantas; Arevalo, Arpys; Foulds, Ian G

    2018-06-04

    In this paper, we present a two-phase microfluidic system capable of incubating and quantifying microbead-based agglutination assays. The microfluidic system is based on a simple fabrication solution, which requires only laboratory tubing filled with carrier oil, driven by negative pressure using a syringe pump. We provide a user-friendly interface, in which a pipette is used to insert single droplets of a 1.25-µL volume into a system that is continuously running and therefore works entirely on demand without the need for stopping, resetting or washing the system. These assays are incubated by highly efficient passive mixing with a sample-to-answer time of 2.5 min, a 5⁻10-fold improvement over traditional agglutination assays. We study system parameters such as channel length, incubation time and flow speed to select optimal assay conditions, using the streptavidin-biotin interaction as a model analyte quantified using optical image processing. We then investigate the effect of changing the concentration of both analyte and microbead concentrations, with a minimum detection limit of 100 ng/mL. The system can be both low- and high-throughput, depending on the rate at which assays are inserted. In our experiments, we were able to easily produce throughputs of 360 assays per hour by simple manual pipetting, which could be increased even further by automation and parallelization. Agglutination assays are a versatile tool, capable of detecting an ever-growing catalog of infectious diseases, proteins and metabolites. A system such as this one is a step towards being able to produce high-throughput microfluidic diagnostic solutions with widespread adoption. The development of analytical techniques in the microfluidic format, such as the one presented in this work, is an important step in being able to continuously monitor the performance and microfluidic outputs of organ-on-chip devices.

  17. Teaching laboratory neuroscience at bowdoin: the laboratory instructor perspective.

    PubMed

    Hauptman, Stephen; Curtis, Nancy

    2009-01-01

    Bowdoin College is a small liberal arts college that offers a comprehensive Neuroscience major. The laboratory experience is an integral part of the major, and many students progress through three stages. A core course offers a survey of concepts and techniques. Four upper-level courses function to give students more intensive laboratory research experience in neurophysiology, molecular neurobiology, social behavior, and learning and memory. Finally, many majors choose to work in the individual research labs of the Neuroscience faculty. We, as laboratory instructors, are vital to the process, and are actively involved in all aspects of the lab-based courses. We provide student instruction in state of the art techniques in neuroscience research. By sharing laboratory teaching responsibilities with course professors, we help to prepare students for careers in laboratory neuroscience and also support and facilitate faculty research programs.

  18. The Language Laboratory.

    ERIC Educational Resources Information Center

    Hughes, John P.

    Concepts pertaining to the language laboratory are clarified for the layman unfamiliar with recent educational developments in foreign language instruction. These include discussion of: (1) language laboratory components and functions, (2) techniques used in the laboratory, (3) new linguistic methods, (4) laboratory exercises, (5) traditional…

  19. The laboratory diagnosis of testosterone deficiency.

    PubMed

    Paduch, Darius A; Brannigan, Robert E; Fuchs, Eugene F; Kim, Edward D; Marmar, Joel L; Sandlow, Jay I

    2014-05-01

    The evaluation and treatment of hypogonadal men has become an important part of urologic practice. Fatigue, loss of libido, and erectile dysfunction are commonly reported, but nonspecific symptoms and laboratory verification of low testosterone (T) are an important part of evaluation in addition to a detailed history and physical examination. Significant intraindividual fluctuations in serum T levels, biologic variation of T action on end organs, the wide range of T levels in human serum samples, and technical limitations of currently available assays have led to poor reliability of T measurements in the clinical laboratory setting. There is no universally accepted threshold of T concentration that distinguishes eugonadal from hypogonadal men; thus, laboratory results have to be interpreted in the appropriate clinical setting. This review focuses on clinical, biological, and technological challenges that affect serum T measurements to educate clinicians regarding technological advances and limitations of the currently available laboratory methods to diagnose hypogonadism. A collaborative effort led by the American Urological Association between practicing clinicians, patient advocacy groups, government regulatory agencies, industry, and professional societies is underway to provide optimized assay platforms and evidence-based normal assay ranges to guide clinical decision making. Until such standardization is commonplace in clinical laboratories, the decision to treat should be based on the presence of signs and symptoms in addition to serum T measurements. Rigid interpretation of T ranges should not dictate clinical decision making or define coverage of treatment by third party payers. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Diagnostic use of 3 techniques for identification of microsporidian spores among AIDS patients in Portugal.

    PubMed

    Matos, Olga; Lobo, Maria L; Gonçalves, Luzia; Antunes, Francisco

    2002-01-01

    The calcofluor stain (CF), the monoclonal antibody (MAb) 3B6 indirect immunofluorescence assay (IFA) and the modified trichrome blue stain (MT) were compared in terms of their reproducibility in a routine laboratory and in order to evaluate the percentage of cases of microsporidiosis in Portuguese HIV patients. A total of 166 faeces samples, 71 pulmonary specimens and 43 urine samples were studied using the 3 techniques. CF had a high sensitivity and a moderate specificity when applied to faeces samples. The sensitivity was lower with pulmonary specimens. The method is easy and quick to perform but readings take a long time to obtain. The MAb 3B6 IFA had a good to excellent sensitivity when applied to faeces and urine samples, but moderate sensitivity in pulmonary specimens. Readings were quick and easy to obtain, but the assay took longer to perform than the other 2 techniques. There was a greater correlation between the results obtained with the MT and MAb 3B6 IFA techniques than between those obtained with the MT and CF techniques. In conclusion, the MT performed better than the MAb 3B6 IFA and CF and continues to have an important place in a routine laboratory for the diagnosis of microsporidiosis. This work also confirms the existence of a relatively high proportion (30%) of cases of infection with Microsporidia, especially intestinal microsporidiosis, in HIV patients in Portugal.

  1. Performance Tested Method multiple laboratory validation study of ELISA-based assays for the detection of peanuts in food.

    PubMed

    Park, Douglas L; Coates, Scott; Brewer, Vickery A; Garber, Eric A E; Abouzied, Mohamed; Johnson, Kurt; Ritter, Bruce; McKenzie, Deborah

    2005-01-01

    Performance Tested Method multiple laboratory validations for the detection of peanut protein in 4 different food matrixes were conducted under the auspices of the AOAC Research Institute. In this blind study, 3 commercially available ELISA test kits were validated: Neogen Veratox for Peanut, R-Biopharm RIDASCREEN FAST Peanut, and Tepnel BioKits for Peanut Assay. The food matrixes used were breakfast cereal, cookies, ice cream, and milk chocolate spiked at 0 and 5 ppm peanut. Analyses of the samples were conducted by laboratories representing industry and international and U.S governmental agencies. All 3 commercial test kits successfully identified spiked and peanut-free samples. The validation study required 60 analyses on test samples at the target level 5 microg peanut/g food and 60 analyses at a peanut-free level, which was designed to ensure that the lower 95% confidence limit for the sensitivity and specificity would not be <90%. The probability that a test sample contains an allergen given a prevalence rate of 5% and a positive test result using a single test kit analysis with 95% sensitivity and 95% specificity, which was demonstrated for these test kits, would be 50%. When 2 test kits are run simultaneously on all samples, the probability becomes 95%. It is therefore recommended that all field samples be analyzed with at least 2 of the validated kits.

  2. Demonstrating the feasibility of large-scale development of standardized assays to quantify human proteins

    PubMed Central

    Kennedy, Jacob J.; Abbatiello, Susan E.; Kim, Kyunggon; Yan, Ping; Whiteaker, Jeffrey R.; Lin, Chenwei; Kim, Jun Seok; Zhang, Yuzheng; Wang, Xianlong; Ivey, Richard G.; Zhao, Lei; Min, Hophil; Lee, Youngju; Yu, Myeong-Hee; Yang, Eun Gyeong; Lee, Cheolju; Wang, Pei; Rodriguez, Henry; Kim, Youngsoo; Carr, Steven A.; Paulovich, Amanda G.

    2014-01-01

    The successful application of MRM in biological specimens raises the exciting possibility that assays can be configured to measure all human proteins, resulting in an assay resource that would promote advances in biomedical research. We report the results of a pilot study designed to test the feasibility of a large-scale, international effort in MRM assay generation. We have configured, validated across three laboratories, and made publicly available as a resource to the community 645 novel MRM assays representing 319 proteins expressed in human breast cancer. Assays were multiplexed in groups of >150 peptides and deployed to quantify endogenous analyte in a panel of breast cancer-related cell lines. Median assay precision was 5.4%, with high inter-laboratory correlation (R2 >0.96). Peptide measurements in breast cancer cell lines were able to discriminate amongst molecular subtypes and identify genome-driven changes in the cancer proteome. These results establish the feasibility of a scaled, international effort. PMID:24317253

  3. Policies and practices in haemostasis testing among laboratories in Croatia: a survey on behalf of a Working Group for Laboratory Coagulation of the Croatian Society of Medical Biochemistry and Laboratory Medicine

    PubMed Central

    Bronić, Ana; Herak, Desiree Coen; Margetić, Sandra; Milić, Marija

    2017-01-01

    Introduction The objective of this survey was to assess current policies and practice in haemostasis testing among both hospital and outpatient laboratories in Republic of Croatia. Materials and methods A questionnaire with seventy questions divided into nine sections was created in May 2015. Participants were asked about their practice related to test request form, sample collection, prothrombin time (PT) and activated partial thromboplastin time assays, other individual haemostasis assays, point-of-care testing (POCT), reporting of coagulation tests results and quality assurance of procedures, the personnel and other laboratory resources, as well as on issues related to education and implementation of additional coagulation assays in their laboratory. The survey was administered and data were collected between June and September 2015. Results A total survey response rate was 104/170 (61.2%). Most respondents were faced with incomplete information on prescribed therapy and diagnosis on the test request or inappropriate samples withdrawn on distant locations, but also do not have protocols for handling samples with high haematocrit values. Reporting of PT-INR and D-dimer results was different between laboratories. Although almost all laboratories developed a critical value reporting system, reporting a value to general practitioners is still a problem. Result on coagulation POCT testing showed that not all devices were supervised by laboratories, which is not in compliance with Croatian Chamber of Medical Biochemistry acts. Conclusion Obtained results highlighted areas that need improvement and different practice patterns in particular field of haemostasis testing among laboratories. A harmonization of the overall process of haemostasis testing at national level should be considered and undertaken. PMID:28392741

  4. Development of an enzyme-linked immunosorbent assay for the detection of dicamba.

    PubMed

    Clegg, B S; Stephenson, G R; Hall, J C

    2001-05-01

    A competitive indirect enzyme-linked immunosorbent assay (CI-ELISA) was developed to quantitate the herbicide dicamba (3,6-dichloro-2-methoxybenzoic acid) in water. The CI-ELISA has a detection limit of 2.3 microg L(-1) and a linear working range of 10--10000 microg L(-1) with an IC(50) value of 195 microg L(-1). The dicamba polyclonal antisera did not cross-react with a number of other herbicides tested but did cross-react with a dicamba metabolite, 5-hydroxydicamba, and structurally related chlorobenzoic acids. The assay was used to estimate quantitatively dicamba concentrations in water samples. Water samples were analyzed directly, and no sample preparation was required. To improve detection limits, a C(18) (reversed phase) column concentration step was devised prior to analysis, and the detection limits were increased by at least by 10-fold. After the sample preconcentration, the detection limit, IC(50), and linear working range were 0.23, 19.5, and 5-200 microg L(-1), respectively. The CI-ELISA estimations in water correlated well with those from gas chromatography-mass spectrometry (GC-MS) analysis (r(2) = 0.9991). This assay contributes to reducing laboratory costs associated with the conventional GC-MS residue analysis techniques for the quantitation of dicamba in water.

  5. The level of laboratory testing required for diagnosis or exclusion of a platelet function disorder using platelet aggregation and secretion assays.

    PubMed

    Mezzano, Diego; Quiroga, Teresa; Pereira, Jaime

    2009-03-01

    The major advances from research on platelet molecular and cell biology, physiology, and pathophysiology over the past decades have not been adequately translated to clinical laboratory diagnosis. Hereditary platelet function disorders (PFDs) are at least as prevalent in the general population as von Willebrand disease (VWD) although PFDs tend not be as well recognized or evaluated. Clinical mucous and skin bleeding in patients with PFDs is prototypic of primary hemostasis disorders, and the bleeding pattern is not distinguishable from that of other primary hemostasis disorders such as VWD. However, different treatment needs, between these discrete disorders, make a precise diagnosis mandatory. Currently, clinicians receive reliable laboratory reports when testing patients with severe PFDs, such as Glanzmann thrombasthenia and Bernard-Soulier syndrome, due to the distinctive laboratory defects that these disorders present, together with the availability of differential diagnostic tests. This is not the case for the majority of PFDs generically classified as "platelet secretion disorders," which are a heterogeneous group of "mild bleeding disorders," for which there are not universally accepted diagnostic criteria. An important reason for robust diagnostic tests is the high proportion (more than 50% in some reports) of patients with unequivocal bleeding who have no precise diagnosis established after a complete laboratory workup. It is paradoxical that the current "gold standard" test for PFD diagnosis, light transmission aggregometry (LTA), has not been standardized after more than four decades of worldwide clinical use. This review describes current diagnostic assays for PFD in a clinical hemostasis laboratory, relating these with current knowledge on platelet function and pathophysiology. Special emphasis will be given to LTA and platelet secretion tests, as well as to the reasons why sensitive tests are needed to explore the lesser known participation of

  6. Performance standard-based validation study for local lymph node assay: 5-bromo-2-deoxyuridine-flow cytometry method.

    PubMed

    Ahn, Ilyoung; Kim, Tae-Sung; Jung, Eun-Sun; Yi, Jung-Sun; Jang, Won-Hee; Jung, Kyoung-Mi; Park, Miyoung; Jung, Mi-Sook; Jeon, Eun-Young; Yeo, Kyeong-Uk; Jo, Ji-Hoon; Park, Jung-Eun; Kim, Chang-Yul; Park, Yeong-Chul; Seong, Won-Keun; Lee, Ai-Young; Chun, Young Jin; Jeong, Tae Cheon; Jeung, Eui Bae; Lim, Kyung-Min; Bae, SeungJin; Sohn, Soojung; Heo, Yong

    2016-10-01

    Local lymph node assay: 5-bromo-2-deoxyuridine-flow cytometry method (LLNA: BrdU-FCM) is a modified non-radioisotopic technique with the additional advantages of accommodating multiple endpoints with the introduction of FCM, and refinement and reduction of animal use by using a sophisticated prescreening scheme. Reliability and accuracy of the LLNA: BrdU-FCM was determined according to OECD Test Guideline (TG) No. 429 (Skin Sensitization: Local Lymph Node Assay) performance standards (PS), with the participation of four laboratories. Transferability was demonstrated through successfully producing stimulation index (SI) values for 25% hexyl cinnamic aldehyde (HCA) consistently greater than 3, a predetermined threshold, by all participating laboratories. Within- and between-laboratory reproducibility was shown using HCA and 2,4-dinitrochlorobenzene, in which EC2.7 values (the estimated concentrations eliciting an SI of 2.7, the threshold for LLNA: BrdU-FCM) fell consistently within the acceptance ranges, 0.025-0.1% and 5-20%, respectively. Predictive capacity was tested using the final protocol version 1.3 for the 18 reference chemicals listed in OECD TG 429, of which results showed 84.6% sensitivity, 100% specificity, and 88.9% accuracy compared with the original LLNA. The data presented are considered to meet the performance criteria for the PS, and its predictive capacity was also sufficiently validated. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Direct /sup 125/I-radioligand assays for serum progesterone compared with assays involving extraction of serum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ratcliffe, W.A.; Corrie, J.E.; Dalziel, A.H.

    1982-06-01

    Researchers compared two direct radioimmunoassays for progesterone in 50 microL of unextracted serum or plasma with assays involving extraction of serum. The direct assays include the use of either danazol at pH 7.4 or 8-anilino-1-naphthalenesulfonic acid at pH 4.0 to displace progesterone from serum binding-proteins. Progesterone is then assayed by using an antiserum to a progesterone 11 alpha hemisuccinyl conjugate and the radioligand /sup 125/I-labeled progesterone 11 alpha-glucuronyl tyramine, with separation by double-antibody techniques. Direct assays with either displacing agent gave good analytical recovery of progesterone added to human serum, and progesterone values for patients' specimens correlated well (r greatermore » than 0.96) with results of assays involving extraction of serum. Precision was similar with each displacing agent over the working range 2.5-100 nmol/L and superior to that of extraction assays. Researchers conclude that these direct assays of progesterone are analytically valid and more robust, precise, and technically convenient than many conventional methods involving extraction of serum.« less

  8. Direct /sup 125/I-radioligand assays for serum progesterone compared with assays involving extraction of serum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ratcliffe, W.A.; Corrie, J.E.T.; Dalziel, A.H.

    1982-06-01

    Two direct radioimmunoassays for progesterone in 50 ..mu..L of unextracted serum or plasma with assays involving extraction of serum were compared. The direct assays include the use of either danazol at pH 7.4 or 8-anilino-1-naphthalenesulfonic acid at pH 4.0 to displace progesterone from serum binding-proteins. Progesterone is then assayed by using an antiserum to a progesterone 11..cap alpha..-hemisuccinyl conjugate and the radioligand /sup 125/I-labeled progesterone 11..cap alpha..-glucuronyl tyramine, with separation by double-antibody techniques. Direct assays with either displacing agent gave good analytical recovery of progesterone added to human serum, and progesterone values for patients' specimens correlated well (r > 0.96)more » with results of assays involving extraction of serum. Precision was similar with each displacing agent over the working range 2.5-100 nmol/L and superior to that of extraction assays. We conclude that these direct assays of progesterone are analytically valid and more robust, precise, and technically convenient than many conventional methods involving extraction of serum.« less

  9. Rapid extraction and assay of uranium from environmental surface samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barrett, Christopher A.; Chouyyok, Wilaiwan; Speakman, Robert J.

    Extraction methods enabling faster removal and concentration of uranium compounds for improved trace and low-level assay are demonstrated for standard surface sampling material in support of nuclear safeguards efforts, health monitoring, and other nuclear analysis applications. A key problem with the existing surface sampling swipes is the requirement for complete digestion of sample and sampling matrix. This is a time-consuming and labour-intensive process that limits laboratory throughput, elevates costs, and increases background levels. Various extraction methods are explored for their potential to quickly and efficiently remove different chemical forms of uranium from standard surface sampling material. A combination of carbonatemore » and peroxide solutions is shown to give the most rapid and complete form of uranyl compound extraction and dissolution. This rapid extraction process is demonstrated to be compatible with standard inductive coupled plasma mass spectrometry methods for uranium isotopic assay as well as screening techniques such as x-ray fluorescence. The general approach described has application beyond uranium to other analytes of nuclear forensic interest (e.g., rare earth elements and plutonium) as well as heavy metals for environmental and industrial hygiene monitoring.« less

  10. Recombinant to modified factor VIII and factor IX - chromogenic and one-stage assays issues.

    PubMed

    Kitchen, S; Kershaw, G; Tiefenbacher, S

    2016-07-01

    The recent development of modified recombinant factor VIII (FVIII) and factor IX (FIX) therapeutic products with extended half-lives will create challenges for the haemostasis laboratory in obtaining recovery estimates of these products in clinical samples using existing assays. The new long-acting therapeutic concentrates contain molecular modifications of Fc fusion, site-specific of polyethylene glycol or albumin fusion. The optimum methods for monitoring each new product will need to be assessed individually and laboratories should select an assay which gives similar results to the assay used to assign potency to the product in question. For some extended half-life FVIII and FIX products some one stage assays are entirely unsuitable for monitoring purposes. For most products and assay reagents studied so far, and reviewed in this manuscript, chromogenic FVIII or FIX assays can be safely used with conventional plasma standards. If one stage assays are used then they should be performed using carefully selected reagents/methods which have been shown to recover activity close to the labelled potency for the specific product being monitored. © 2016 John Wiley & Sons Ltd.

  11. Engineering of a miniaturized, robotic clinical laboratory.

    PubMed

    Nourse, Marilyn B; Engel, Kate; Anekal, Samartha G; Bailey, Jocelyn A; Bhatta, Pradeep; Bhave, Devayani P; Chandrasekaran, Shekar; Chen, Yutao; Chow, Steven; Das, Ushati; Galil, Erez; Gong, Xinwei; Gessert, Steven F; Ha, Kevin D; Hu, Ran; Hyland, Laura; Jammalamadaka, Arvind; Jayasurya, Karthik; Kemp, Timothy M; Kim, Andrew N; Lee, Lucie S; Liu, Yang Lily; Nguyen, Alphonso; O'Leary, Jared; Pangarkar, Chinmay H; Patel, Paul J; Quon, Ken; Ramachandran, Pradeep L; Rappaport, Amy R; Roy, Joy; Sapida, Jerald F; Sergeev, Nikolay V; Shee, Chandan; Shenoy, Renuka; Sivaraman, Sharada; Sosa-Padilla, Bernardo; Tran, Lorraine; Trent, Amanda; Waggoner, Thomas C; Wodziak, Dariusz; Yuan, Amy; Zhao, Peter; Young, Daniel L; Robertson, Channing R; Holmes, Elizabeth A

    2018-01-01

    The ability to perform laboratory testing near the patient and with smaller blood volumes would benefit patients and physicians alike. We describe our design of a miniaturized clinical laboratory system with three components: a hardware platform (ie, the miniLab) that performs preanalytical and analytical processing steps using miniaturized sample manipulation and detection modules, an assay-configurable cartridge that provides consumable materials and assay reagents, and a server that communicates bidirectionally with the miniLab to manage assay-specific protocols and analyze, store, and report results (i.e., the virtual analyzer). The miniLab can detect analytes in blood using multiple methods, including molecular diagnostics, immunoassays, clinical chemistry, and hematology. Analytical performance results show that our qualitative Zika virus assay has a limit of detection of 55 genomic copies/ml. For our anti-herpes simplex virus type 2 immunoglobulin G, lipid panel, and lymphocyte subset panel assays, the miniLab has low imprecision, and method comparison results agree well with those from the United States Food and Drug Administration-cleared devices. With its small footprint and versatility, the miniLab has the potential to provide testing of a range of analytes in decentralized locations.

  12. Evaluation of the Abbott ARCHITECT Toxo IgM assay.

    PubMed

    Sickinger, Eva; Braun, Hans-Bertram; Praast, Gerald; Stieler, Myriam; Gundlach, Cordelia; Birkenbach, Claudia; Prostko, John; Palafox, Mary Ann; Frias, Edwin; Hsu, Stephen; Matias, Matthew; Pucci, Dominick; Hausmann, Michael; Sagel, Ulrich; Smith, Darwin

    2009-07-01

    Development of the ARCHITECT Toxo IgM assay has been done to assist the clinician in acute Toxoplasma gondii infection detection, especially in pregnant women. Its use, in conjunction with ARCHITECT Toxo IgG and Toxo Avidity assays, will provide an array of assays particularly useful in the monitoring of pregnant females to determine the risk of maternal transmission of the parasite. Specificity results from 2 testing sites, using populations of pregnant females, hospital patients, and blood donors, demonstrated that the assay has an overall resolved relative specificity of 99.89% (confidence interval, 99.68-99.98%). Relative specificity for pregnant female specimens was 99.95% (n = 2031). Excellent seroconversion sensitivity was observed for the ARCHITECT Toxo IgM assay, which was similar to the Abbott AxSYM Toxo IgM assay (Abbott Laboratories, Abbott Park, IL). In more than 90% of the panels tested, the 1st bleed detected in the serial bleeds was the same for both assays.

  13. Optimization and Validation of the TZM-bl Assay for Standardized Assessments of Neutralizing Antibodies Against HIV-1

    PubMed Central

    Sarzotti-Kelsoe, Marcella; Bailer, Robert T; Turk, Ellen; Lin, Chen-li; Bilska, Miroslawa; Greene, Kelli M.; Gao, Hongmei; Todd, Christopher A.; Ozaki, Daniel A.; Seaman, Michael S.; Mascola, John R.; Montefiori, David C.

    2014-01-01

    The TZM-bl assay measures antibody-mediated neutralization of HIV-1 as a function of reductions in HIV-1 Tat-regulated firefly luciferase (Luc) reporter gene expression after a single round of infection with Env-pseudotyped viruses. This assay has become the main endpoint neutralization assay used for the assessment of preclinical and clinical trial samples by a growing number of laboratories worldwide. Here we present the results of the formal optimization and validation of the TZM-bl assay, performed in compliance with Good Clinical Laboratory Practice (GCLP) guidelines. The assay was evaluated for specificity, accuracy, precision, limits of detection and quantitation, linearity, range and robustness. The validated manual TZM-bl assay was also adapted, optimized and qualified to an automated 384-well format. PMID:24291345

  14. Advances in Developing HIV-1 Viral Load Assays for Resource-Limited Settings

    PubMed Central

    Wang, ShuQi; Xu, Feng; Demirci, Utkan

    2010-01-01

    Commercial HIV-1 RNA viral load assays have been routinely used in developed countries to monitor antiretroviral treatment (ART). However, these assays require expensive equipment and reagents, well-trained operators, and established laboratory infrastructure. These requirements restrict their use in resource-limited settings where people are most afflicted with the HIV-1 epidemic. Inexpensive alternatives such as the Ultrasensitive p24 assay, the Reverse Transcriptase (RT) assay and in-house reverse transcription quantitative polymerase chain reaction (RT-qPCR) have been developed. However, they are still time-consuming, technologically complex and inappropriate for decentralized laboratories as point-of-care (POC) tests. Recent advances in microfluidics and nanotechnology offer new strategies to develop low-cost, rapid, robust and simple HIV-1 viral load monitoring systems. We review state-of-the-art technologies used for HIV-1 viral load monitoring in both developed and developing settings. Emerging approaches based on microfluidics and nanotechnology, which have potential to be integrated into POC HIV-1 viral load assays, are also discussed. PMID:20600784

  15. A rapid Orthopoxvirus purification protocol suitable for high-containment laboratories.

    PubMed

    Hughes, Laura; Wilkins, Kimberly; Goldsmith, Cynthia S; Smith, Scott; Hudson, Paul; Patel, Nishi; Karem, Kevin; Damon, Inger; Li, Yu; Olson, Victoria A; Satheshkumar, P S

    2017-05-01

    Virus purification in a high-containment setting provides unique challenges due to barrier precautions and operational safety approaches that are not necessary in lower biosafety level (BSL) 2 environments. The need for high risk group pathogen diagnostic assay development, anti-viral research, pathogenesis and vaccine efficacy research necessitates work in BSL-3 and BSL-4 labs with infectious agents. When this work is performed in accordance with BSL-4 practices, modifications are often required in standard protocols. Classical virus purification techniques are difficult to execute in a BSL-3 or BSL-4 laboratory because of the work practices used in these environments. Orthopoxviruses are a family of viruses that, in some cases, requires work in a high-containment laboratory and due to size do not lend themselves to simpler purification methods. Current CDC purification techniques of orthopoxviruses uses 1,1,2-trichlorotrifluoroethane, commonly known as Genetron ® . Genetron ® is a chlorofluorocarbon (CFC) that has been shown to be detrimental to the ozone and has been phased out and the limited amount of product makes it no longer a feasible option for poxvirus purification purposes. Here we demonstrate a new Orthopoxvirus purification method that is suitable for high-containment laboratories and produces virus that is not only comparable to previous purification methods, but improves on purity and yield. Published by Elsevier B.V.

  16. CLSI-based transference and verification of CALIPER pediatric reference intervals for 29 Ortho VITROS 5600 chemistry assays.

    PubMed

    Higgins, Victoria; Truong, Dorothy; Woroch, Amy; Chan, Man Khun; Tahmasebi, Houman; Adeli, Khosrow

    2018-03-01

    Evidence-based reference intervals (RIs) are essential to accurately interpret pediatric laboratory test results. To fill gaps in pediatric RIs, the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) project developed an age- and sex-specific pediatric RI database based on healthy pediatric subjects. Originally established for Abbott ARCHITECT assays, CALIPER RIs were transferred to assays on Beckman, Roche, Siemens, and Ortho analytical platforms. This study provides transferred reference intervals for 29 biochemical assays for the Ortho VITROS 5600 Chemistry System (Ortho). Based on Clinical Laboratory Standards Institute (CLSI) guidelines, a method comparison analysis was performed by measuring approximately 200 patient serum samples using Abbott and Ortho assays. The equation of the line of best fit was calculated and the appropriateness of the linear model was assessed. This equation was used to transfer RIs from Abbott to Ortho assays. Transferred RIs were verified using 84 healthy pediatric serum samples from the CALIPER cohort. RIs for most chemistry analytes successfully transferred from Abbott to Ortho assays. Calcium and CO 2 did not meet statistical criteria for transference (r 2 <0.70). Of the 32 transferred reference intervals, 29 successfully verified with approximately 90% of results from reference samples falling within transferred confidence limits. Transferred RIs for total bilirubin, magnesium, and LDH did not meet verification criteria and are not reported. This study broadens the utility of the CALIPER pediatric RI database to laboratories using Ortho VITROS 5600 biochemical assays. Clinical laboratories should verify CALIPER reference intervals for their specific analytical platform and local population as recommended by CLSI. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  17. RNA Whole-Mount In situ Hybridisation Proximity Ligation Assay (rISH-PLA), an Assay for Detecting RNA-Protein Complexes in Intact Cells.

    PubMed

    Roussis, Ioannis M; Guille, Matthew; Myers, Fiona A; Scarlett, Garry P

    2016-01-01

    Techniques for studying RNA-protein interactions have lagged behind those for DNA-protein complexes as a consequence of the complexities associated with working with RNA. Here we present a method for the modification of the existing In Situ Hybridisation-Proximity Ligation Assay (ISH-PLA) protocol to adapt it to the study of RNA regulation (rISH-PLA). As proof of principle we used the well-characterised interaction of the Xenopus laevis Staufen RNA binding protein with Vg1 mRNA, the complex of which co-localises to the vegetal pole of Xenopus oocytes. The applicability of both the Stau1 antibody and the Locked Nucleic Acid probe (LNA) recognising Vg1 mRNA were independently validated by whole-mount Immunohistochemistry and whole-mount in situ hybridisation assays respectively prior to combining them in the rISH-PLA assay. The rISH-PLA assay allows the identification of a given RNA-protein complex at subcellular and single cell resolution, thus avoiding the lack of spatial resolution and sensitivity associated with assaying heterogenous cell populations from which conventional RNA-protein interaction detection techniques suffer. This technique will be particularly usefully for studying the activity of RNA binding proteins (RBPs) in complex mixtures of cells, for example tissue sections or whole embryos.

  18. Single-laboratory validation of the microplate receptor binding assay for paralytic shellfish toxins in shellfish.

    PubMed

    Van Dolah, Frances M; Leighfield, Tod A; Doucette, Gregory J; Bean, Laurie; Niedzwiadek, Barbara; Rawn, Dorothea F K

    2009-01-01

    A single-laboratory validation (SLV) study was conducted for the microplate receptor binding assay (RBA) for paralytic shellfish poisoning (PSP) toxins in shellfish. The basis of the assay is the competition between [3H]saxitoxin (STX) and STX in a standard or sample for binding to the voltage dependent sodium channel. A calibration curve is generated by the addition of 0.01-1000 nM STX, which results in the concentration dependent decrease in [3H]STX-receptor complexes formed and serves to quantify STX in unknown samples. This study established the LOQ, linearity, recovery, accuracy, and precision of the assay for determining PSP toxicity in shellfish extracts, as performed by a single analyst on multiple days. The standard curve obtained on 5 independent days resulted in a half-maximal inhibition (IC50) of 2.3 nM STX +/- 0.3 (RSD = 10.8%) with a slope of 0.96 +/- 0.06 (RSD = 6.3%) and a dynamic range of 1.2-10.0 nM. The LOQ was 5.3 microg STX equivalents/100 g shellfish. Linearity, established by quantification of three levels of purified STX (1.5, 3, and 6 nM), yielded an r2 of 0.97. Recovery from mussels spiked with three levels (40, 80, and 120 microg STX/100 g) averaged 121%. Repeatability (RSD(r)), determined on six naturally contaminated shellfish samples on 5 independent days, was 17.7%. A method comparison with the AOAC mouse bioassay yielded r2 = 0.98 (slope = 1.29) in the SLV study. The effects of the extraction method on RBA-based toxicity values were assessed on shellfish extracted for PSP toxins using the AOAC mouse bioassay method (0.1 M HCI) compared to that for the precolumn oxidation HPLC method (0.1% acetic acid). The two extraction methods showed linear correlation (r2 = 0.99), with the HCl extraction method yielding slightly higher toxicity values (slope = 1.23). A similar relationship was observed between HPLC quantification of the HCI- and acetic acid-extracted samples (r2 = 0.98, slope 1.19). The RBA also had excellent linear correlation

  19. Use of a Rapid Ethylene Glycol Assay: a 4-Year Retrospective Study at an Academic Medical Center.

    PubMed

    Rooney, Sydney L; Ehlers, Alexandra; Morris, Cory; Drees, Denny; Davis, Scott R; Kulhavy, Jeff; Krasowski, Matthew D

    2016-06-01

    Ethylene glycol (EG) is a common cause of toxic ingestions. Gas chromatography (GC)-based laboratory assays are the gold standard for diagnosing EG intoxication. However, GC requires specialized instrumentation and technical expertise that limits feasibility for many clinical laboratories. The objective of this retrospective study was to determine the utility of incorporating a rapid EG assay for management of cases with suspected EG poisoning. The University of Iowa Hospitals and Clinics core clinical laboratory adapted a veterinary EG assay (Catachem, Inc.) for the Roche Diagnostics cobas 8000 c502 analyzer and incorporated this assay in an osmolal gap-based algorithm for potential toxic alcohol/glycol ingestions. The main limitation is that high concentrations of propylene glycol (PG), while readily identifiable by reaction rate kinetics, can interfere with EG measurement. The clinical laboratory had the ability to perform GC for EG and PG, if needed. A total of 222 rapid EG and 24 EG/PG GC analyses were documented in 106 patient encounters. Of ten confirmed EG ingestions, eight cases were managed entirely with the rapid EG assay. PG interference was evident in 25 samples, leading to 8 GC analyses to rule out the presence of EG. Chart review of cases with negative rapid EG assay results showed no evidence of false negatives. The results of this study highlight the use of incorporating a rapid EG assay for the diagnosis and management of suspected EG toxicity by decreasing the reliance on GC. Future improvements would involve rapid EG assays that completely avoid interference by PG.

  20. [Multicenter evaluation of h-FABP semi-quantitative assay (Cardio Detect) in central laboratory: the point in acute myocardial infarction diagnosis].

    PubMed

    Lefèvre, G; Fayet, J-M; Graïne, H; Berny, C; Maupas-Schwalm, F; Capolaghi, B; Morin, C

    2007-01-01

    The diagnostic performance of heart-Fatty Acid Binding Protein (h-FABP) (semi-quantitative CardioDetect test) and cardiac troponin I (TnIc) blood assays were compared in one hundred patients presenting with suspicion of acute coronary syndrome. Final patient diagnosis was "acute myocardial infarction" in 36 cases, "non ST myocardial infarction" in 25 cases and "non ischemic pathologies" in 39 cases. h-FABP results were positive in 26 patients, negative in 57 patients and ambiguous in 17 patients, the latter corresponding to the final diagnosis of "acute myocardial infarction" in 5 cases, "non ST myocardial infarction" in 2 cases and "non ischemic pathologies " in 10 cases. At admission, h-FABP and TnIc exhibiteda sensitivity of 54% an 66%, respectively and a specificity of 86% and 95%, respectively. Positive and negative predictive values were 81% and 64% for h-FABP, respectively and 92% and 75% for cTnI, respectively. h-FABP and cTnI demonstrated a similar diagnostic efficiency if admission delay is less than 4 hours after onset of chest pain (area under ROC curve TnIc = 0.767 +/- 0.091 ; area under ROC curve h-FABP = 0.622 +/- 0.109 ; p = 0.144). On the contrary, cTnI assay demonstrated a better efficiency than h-FABP (p< 0.005) for patients admitted in a delay of 4 to 12 hours after the onset of chest pain. If chosen cTnI cut-off corresponded to the recent consensus definition used for monitoring acute coronary syndrome patients, h-FABP semi-quantitative assay realized within central laboratory did not demonstrated a better diagnostic efficiency than cTnI.

  1. Comparison of the performance of IFA, CFA, and ELISA assays for the serodiagnosis of acute Q fever by quality assessment.

    PubMed

    Herremans, Tineke; Hogema, Boris M; Nabuurs, Marrigje; Peeters, Marcel; Wegdam-Blans, Marjolijn; Schneeberger, Peter; Nijhuis, Carla; Notermans, Daan W; Galama, Joep; Horrevorts, Anton; van Loo, Inge H M; Vlaminckx, Bart; Zaaijer, Hans L; Koopmans, Marion P; Berkhout, Hanneke; Socolovschi, Cristina; Raoult, Didier; Stenos, John; Nicholson, William; Bijlmer, Henk

    2013-01-01

    The indirect immunofluorescence assay (IFA) is considered the reference method for diagnosing Q fever, but serology is also performed by complement fixation assay (CFA) or enzyme-linked immunosorbent assay (ELISA). However, comparability between these assays is not clear, and therefore a quality assessment was performed. A total of 25 serum samples from negative controls, Q fever patients, and a serial diluted high-positive sample were analyzed in 10 Dutch laboratories. Six laboratories performed CFA, 5 performed IFA, and 5 performed ELISAs. Three international reference laboratories from Australia, France, and the USA also participated in this study. Qualitative values between laboratories using the same methods were within close range, and all 3 methods correctly identified acute Q fever patients. The IFA, ELISA, and CFA are all suitable serodiagnostic assays to diagnose acute Q fever, but the IFA remains an important tool in the follow-up of patients and in identifying patients at risk for developing chronic Q fever. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. The use of laboratory tests in the diagnosis of SLE.

    PubMed

    Egner, W

    2000-06-01

    ANA IIF is an effective screening assay in patients with clinical features of SLE and will detect most anti-ssDNA, anti-dsDNA, ENAs, and other autoantibodies. False positives are common. The clinical importance cannot be extrapolated from the ANA titre or pattern, although higher titres (> 1/160) are more likely to be important. HEp-2 cells are the most sensitive substrate for ANA detection, but this must be balanced against an increased incidence of insignificant positivity. ANA positive samples should be subjected to more specific assays for the diagnosis of SLE. A combination of ENA (Ro/La/Sm/RNP) and dsDNA assays will detect most patients with SLE as long as the characteristics of the assays used are well understood. ESR and CRP measurements provide useful additional information. Sjogren's syndrome and MCTD will produce overlapping serology with SLE, and anti-dsDNA titres are sometimes seen in autoimmune hepatitis and rheumatoid arthritis. All results should be reported in the light of the clinical details, by an experienced immunologist. A suggested diagnostic protocol is outlined in fig 1. The type of assay used crucially influences the predictive value of the tests. ELISA technology dominates routine laboratory practice, but tends to produce more false positive and true weak positive results, which may reduce the PPV of the test. This can be minimised by using IgG specific conjugates and careful assay validation. The NPV for SLE [figure: see text] is high for most assays but the PPV varies. Where necessary, laboratories should use crithidia or Farr dsDNA assays to confirm dubious ELISA dsDNA results, and ID/IB to confirm dubious ENA results. For monitoring, a precise, quantitative assay is required. It is unclear whether the detection of IgM or low affinity antibodies has a role here. A combination of anti-dsDNA, C3, C4, CRP, and ESR assays provides the most useful clinical information. Anti-ssDNA assays are likely to be useful, and are potentially more

  3. Interferences from blood collection tube components on clinical chemistry assays

    PubMed Central

    Bowen, Raffick A.R.; Remaley, Alan T.

    2014-01-01

    Improper design or use of blood collection devices can adversely affect the accuracy of laboratory test results. Vascular access devices, such as catheters and needles, exert shear forces during blood flow, which creates a predisposition to cell lysis. Components from blood collection tubes, such as stoppers, lubricants, surfactants, and separator gels, can leach into specimens and/or adsorb analytes from a specimen; special tube additives may also alter analyte stability. Because of these interactions with blood specimens, blood collection devices are a potential source of pre-analytical error in laboratory testing. Accurate laboratory testing requires an understanding of the complex interactions between collection devices and blood specimens. Manufacturers, vendors, and clinical laboratorians must consider the pre-analytical challenges in laboratory testing. Although other authors have described the effects of endogenous substances on clinical assay results, the effects/impact of blood collection tube additives and components have not been well systematically described or explained. This review aims to identify and describe blood collection tube additives and their components and the strategies used to minimize their effects on clinical chemistry assays. PMID:24627713

  4. Optimization of the cydex blue assay: A one-step colorimetric protein assay using cyclodextrins and compatible with detergents and reducers

    PubMed Central

    2018-01-01

    Sodium dodecyl sulfate electrophoresis (SDS) is a protein separation technique widely used, for example, prior to immunoblotting. Samples are usually prepared in a buffer containing both high concentrations of reducers and high concentrations of SDS. This conjunction renders the samples incompatible with common protein assays. By chelating the SDS, cyclodextrins make the use of simple, dye-based colorimetric assays possible. In this paper, we describe the optimization of the assay, focussing on the cyclodextrin/SDS ratio and the use of commercial assay reagents. The adaptation of the assay to a microplate format and using other detergent-containing conventional extraction buffers is also described. PMID:29641569

  5. Evaluation of agglutination strength by a flow-induced cell movement assay based surface plasmon resonance (SPR) technique.

    PubMed

    Sudprasert, Krisda; Peungthum, Patjaree; Vongsakulyanon, Apirom; Amarit, Ratthasart; Somboonkaew, Armote; Sutapun, Boonsong; Kitpoka, Pimpun; Kunakorn, Mongkol; Srikhirin, Toemsak

    2015-02-07

    A flow-induced cell movement assay combined with a surface plasmon resonance (SPR) technique was developed to quantify the agglutination strength, derived from the standard tube-agglutination test. Red blood cells (RBCs), based on the ABO blood group system, were specifically captured by anti-A and/or anti-B antibodies immobilized on a sensor surface. The agglutination strength corresponds to the amount of antigen-antibody interactions or the strength of RBC adhesion. Under a shear flow, the adherent RBCs were forced to move out of the region of interest with different average cell velocities (vc) depending upon the adhesion strength and wall shear stress (WSS). That is, a higher adhesion strength (higher agglutination strength) or lower WSS represents a lower vc or vice versa. In this work, the agglutination strength was derived from the vc that was calculated from the time derivative of the relative SPR signal by using a simple model of cell movement response, whose validity was verified. The vc values of different samples were correlated with their agglutination strengths at a given WSS and antibody surface density. The vc decreased as the agglutination strength increased, which can be considered as a linear regression. The coefficient of variation of the calculated vc decreased to 0.1 as vc increased to 30 μm min(-1). The sensitivity of this assay can be controlled by optimizing the antibody surface density or the WSS. This assay has the capability to resolve the antigen density of A1 and B RBCs from that of A1B RBCs.

  6. Flow Cytometric Immunobead Assay for Detection of BCR-ABL1 Fusion Proteins in Chronic Myleoid Leukemia: Comparison with FISH and PCR Techniques

    PubMed Central

    Recchia, Anna Grazia; Caruso, Nadia; Bossio, Sabrina; Pellicanò, Mariavaleria; De Stefano, Laura; Franzese, Stefania; Palummo, Angela; Abbadessa, Vincenzo; Lucia, Eugenio; Gentile, Massimo; Vigna, Ernesto; Caracciolo, Clementina; Agostino, Antolino; Galimberti, Sara; Levato, Luciano; Stagno, Fabio; Molica, Stefano; Martino, Bruno; Vigneri, Paolo; Di Raimondo, Francesco; Morabito, Fortunato

    2015-01-01

    Chronic Myeloid Leukemia (CML) is characterized by a balanced translocation juxtaposing the Abelson (ABL) and breakpoint cluster region (BCR) genes. The resulting BCR-ABL1 oncogene leads to increased proliferation and survival of leukemic cells. Successful treatment of CML has been accompanied by steady improvements in our capacity to accurately and sensitively monitor therapy response. Currently, measurement of BCR-ABL1 mRNA transcript levels by real-time quantitative PCR (RQ-PCR) defines critical response endpoints. An antibody-based technique for BCR-ABL1 protein recognition could be an attractive alternative to RQ-PCR. To date, there have been no studies evaluating whether flow-cytometry based assays could be of clinical utility in evaluating residual disease in CML patients. Here we describe a flow-cytometry assay that detects the presence of BCR-ABL1 fusion proteins in CML lysates to determine the applicability, reliability, and specificity of this method for both diagnosis and monitoring of CML patients for initial response to therapy. We show that: i) CML can be properly diagnosed at onset, (ii) follow-up assessments show detectable fusion protein (i.e. relative mean fluorescent intensity, rMFI%>1) when BCR-ABL1IS transcripts are between 1–10%, and (iii) rMFI% levels predict CCyR as defined by FISH analysis. Overall, the FCBA assay is a rapid technique, fully translatable to the routine management of CML patients. PMID:26111048

  7. An interlaboratory transfer of a multi-analyte assay between continents.

    PubMed

    Georgiou, Alexandra; Dong, Kelly; Hughes, Stephen; Barfield, Matthew

    2015-01-01

    Alex has worked at GlaxoSmithKline for the past 15 years and currently works within the bioanalytical and toxicokinetic group in the United Kingdom. Alex's role in previous years has been the in-house support of preclinical and clinical bioanalysis, from method development through to sample analysis activities as well as acting as PI for GLP bioanalysis and toxicokinetics. For the past two years, Alex has applied this analytical and regulatory experience to focus on the outsourcing of preclinical bioanalysis, toxicokinetics and clinical bioanalysis, working closely with multiple bioanalytical and in-life CRO partners worldwide. Alex works to support DMPK and Safety Assessment outsourcing activities for GSK across multiple therapeutic areas, from the first GLP study through to late stage clinical PK studies. Transfer and cross-validation of an existing analytical assay between a laboratory providing current analytical support, and a laboratory needed for new or additional support, can present the bioanalyst with numerous challenges. These challenges can be technical or logistical in nature and may prove to be significant when transferring an assay between laboratories in different continents. Part of GlaxoSmithKline's strategy to improve confidence in providing quality data, is to cross-validate between laboratories. If the cross-validation fails predefined acceptance criteria, then a subsequent investigation would follow. This may also prove to be challenging. The importance of thorough planning and good communication throughout assay transfer, cross-validation and any subsequent investigations is illustrated in this case study.

  8. Thermometric enzyme linked immunosorbent assay: TELISA.

    PubMed

    Mattiasson, B; Borrebaeck, C; Sanfridson, B; Mosbach, K

    1977-08-11

    A new method, thermometric enzyme linked immunosorbent assay (TELISA), for the assay of endogenous and exogenous compounds in biological fluids is described. It is based on the previously described enzyme linked immunosorbent assay technique, ELISA, but utilizes enzymic heat formation which is measured in an enzyme thermistor unit. In the model system studied determination of human serum albumin down to a concentration of 10(-10) M (5 ng/ml) was achieved, with both normal and catalase labelled human serum albumin competing for the binding sites on the immunosorbent, which was rabbit antihuman serum albumin immobilized onto Sepharose CL-4B.

  9. Robotic implementation of assays: tissue-nonspecific alkaline phosphatase (TNAP) case study.

    PubMed

    Chung, Thomas D Y

    2013-01-01

    Laboratory automation and robotics have "industrialized" the execution and completion of large-scale, enabling high-capacity and high-throughput (100 K-1 MM/day) screening (HTS) campaigns of large "libraries" of compounds (>200 K-2 MM) to complete in a few days or weeks. Critical to the success these HTS campaigns is the ability of a competent assay development team to convert a validated research-grade laboratory "benchtop" assay suitable for manual or semi-automated operations on a few hundreds of compounds into a robust miniaturized (384- or 1,536-well format), well-engineered, scalable, industrialized assay that can be seamlessly implemented on a fully automated, fully integrated robotic screening platform for cost-effective screening of hundreds of thousands of compounds. Here, we provide a review of the theoretical guiding principles and practical considerations necessary to reduce often complex research biology into a "lean manufacturing" engineering endeavor comprising adaption, automation, and implementation of HTS. Furthermore we provide a detailed example specifically for a cell-free in vitro biochemical, enzymatic phosphatase assay for tissue-nonspecific alkaline phosphatase that illustrates these principles and considerations.

  10. Evaluation of the HISCL Anti-Treponema pallidum Assay as a Screening Test for Syphilis

    PubMed Central

    An, Jingna; Chen, Qixia; Liu, Qianqian; Rao, Chenli; Li, Dongdong; Wang, Tingting

    2015-01-01

    The resurgence of syphilis in recent years has become a serious threat to public health worldwide, and the serological detection of specific antibodies against Treponema pallidum remains the most reliable method for laboratory diagnosis of syphilis. This study examined the performance of the recently launched HISCL anti-Treponema pallidum (anti-TP) assay as a screening test for syphilis in a high-volume laboratory. The HISCL anti-TP assay was tested in 300 preselected syphilis-positive samples, 704 fresh syphilis-negative samples, 48 preselected potentially interfering samples, and 30 “borderline” samples and was compared head to head with the commercially available Lumipulse G TP-N. In this study, the HISCL anti-TP assay was in perfect agreement with the applied testing algorithms with an overall agreement of 100%, comparable to that of Lumipulse G TP-N (99.63%). The sensitivity and specificity of the HISCL anti-TP assay were 100% (95% confidence interval [CI], 98.42% to 100%) and 100% (95% CI, 99.37% to 100%), respectively. Considering the excellent ease of use and automation, high throughput, and its favorable sensitivity and specificity, the HISCL anti-TP assay may represent a new choice for syphilis screening in high-volume laboratories. PMID:25972403

  11. Evaluation of the HISCL Anti-Treponema pallidum Assay as a Screening Test for Syphilis.

    PubMed

    An, Jingna; Chen, Qixia; Liu, Qianqian; Rao, Chenli; Li, Dongdong; Wang, Tingting; Tao, Chuanmin; Wang, Lanlan

    2015-07-01

    The resurgence of syphilis in recent years has become a serious threat to public health worldwide, and the serological detection of specific antibodies against Treponema pallidum remains the most reliable method for laboratory diagnosis of syphilis. This study examined the performance of the recently launched HISCL anti-Treponema pallidum (anti-TP) assay as a screening test for syphilis in a high-volume laboratory. The HISCL anti-TP assay was tested in 300 preselected syphilis-positive samples, 704 fresh syphilis-negative samples, 48 preselected potentially interfering samples, and 30 "borderline" samples and was compared head to head with the commercially available Lumipulse G TP-N. In this study, the HISCL anti-TP assay was in perfect agreement with the applied testing algorithms with an overall agreement of 100%, comparable to that of Lumipulse G TP-N (99.63%). The sensitivity and specificity of the HISCL anti-TP assay were 100% (95% confidence interval [CI], 98.42% to 100%) and 100% (95% CI, 99.37% to 100%), respectively. Considering the excellent ease of use and automation, high throughput, and its favorable sensitivity and specificity, the HISCL anti-TP assay may represent a new choice for syphilis screening in high-volume laboratories. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  12. Analysis of Gold Ores by Fire Assay

    ERIC Educational Resources Information Center

    Blyth, Kristy M.; Phillips, David N.; van Bronswijk, Wilhelm

    2004-01-01

    Students of an Applied Chemistry degree course carried out a fire-assay exercise. The analysis showed that the technique was a worthwhile quantitative analytical technique and covered interesting theory including acid-base and redox chemistry and other concepts such as inquarting and cupelling.

  13. Total protein measurement in canine cerebrospinal fluid: agreement between a turbidimetric assay and 2 dye-binding methods and determination of reference intervals using an indirect a posteriori method.

    PubMed

    Riond, B; Steffen, F; Schmied, O; Hofmann-Lehmann, R; Lutz, H

    2014-03-01

    In veterinary clinical laboratories, qualitative tests for total protein measurement in canine cerebrospinal fluid (CSF) have been replaced by quantitative methods, which can be divided into dye-binding assays and turbidimetric methods. There is a lack of validation data and reference intervals (RIs) for these assays. The aim of the present study was to assess agreement between the turbidimetric benzethonium chloride method and 2 dye-binding methods (Pyrogallol Red-Molybdate method [PRM], Coomassie Brilliant Blue [CBB] technique) for measurement of total protein concentration in canine CSF. Furthermore, RIs were determined for all 3 methods using an indirect a posteriori method. For assay comparison, a total of 118 canine CSF specimens were analyzed. For RIs calculation, clinical records of 401 canine patients with normal CSF analysis were studied and classified according to their final diagnosis in pathologic and nonpathologic values. The turbidimetric assay showed excellent agreement with the PRM assay (mean bias 0.003 g/L [-0.26-0.27]). The CBB method generally showed higher total protein values than the turbidimetric assay and the PRM assay (mean bias -0.14 g/L for turbidimetric and PRM assay). From 90 of 401 canine patients, nonparametric reference intervals (2.5%, 97.5% quantile) were calculated (turbidimetric assay and PRM method: 0.08-0.35 g/L (90% CI: 0.07-0.08/0.33-0.39); CBB method: 0.17-0.55 g/L (90% CI: 0.16-0.18/0.52-0.61). Total protein concentration in canine CSF specimens remained stable for up to 6 months of storage at -80°C. Due to variations among methods, RIs for total protein concentration in canine CSF have to be calculated for each method. The a posteriori method of RIs calculation described here should encourage other veterinary laboratories to establish RIs that are laboratory-specific. ©2014 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.

  14. Evaluation of the DCA Vantage analyzer for HbA 1c assay.

    PubMed

    Szymezak, Jean; Leroy, Nathalie; Lavalard, Emmanuelle; Gillery, Philippe

    2008-01-01

    Measurement of HbA 1c is key in monitoring diabetic patients in both laboratories and clinical units, where HbA 1c results are used as part of patient education. We have evaluated the DCA Vantage, a new device for immunological assay of HbA 1c. HbA 1c results obtained were evaluated in terms of precision, linearity, specificity and practicability, and were compared with results obtained by a Variant II HPLC method. The method exhibited intra- and inter-assay coefficients of variation lower than 2.6% and 4.0%, respectively, and good correlation with the comparison HPLC method (r2=0.9776). No interference was noted in the presence of labile HbA 1c or carbamylated hemoglobin. The new device exhibited improved practicability characteristics and allowed better sample identification, better management of quality control routines and greater connectivity possibilities compared to the previous DCA 2000 analyzer. This new analyzer exhibited analytical and practical characteristics very suitable for HbA 1c assay for laboratory or point-of-care use according to good laboratory practice.

  15. Comprehensive analysis of sperm DNA fragmentation by five different assays: TUNEL assay, SCSA, SCD test and alkaline and neutral Comet assay.

    PubMed

    Ribas-Maynou, J; García-Peiró, A; Fernández-Encinas, A; Abad, C; Amengual, M J; Prada, E; Navarro, J; Benet, J

    2013-09-01

    Sperm DNA fragmentation (SDF) is becoming an important test to assess male infertility. Several different tests are available, but no consensus has yet been reached as to which tests are most predictive of infertility. Few publications have reported a comprehensive analysis comparing these methods within the same population. The objective of this study was to analyze the differences between the five most common methodologies, to study their correlations and to establish their cut-off values, sensitivity and specificity in predicting male infertility. We found differences in SDF between fertile donors and infertile patients in TUNEL, SCSA, SCD and alkaline Comet assays, but none with the neutral Comet assay. The alkaline COMET assay was the best in predicting male infertility followed by TUNEL, SCD and SCSA, whereas the neutral COMET assay had no predictive power. For our patient population, threshold values for infertility were 20.05% for TUNEL assay, 18.90% for SCSA, 22.75% for the SCD test, 45.37% for alkaline Comet and 34.37% for neutral Comet. This work establishes in a comprehensive study that the all techniques except neutral Comet are useful to distinguish fertile and infertile men. © 2013 American Society of Andrology and European Academy of Andrology.

  16. [Investigation of reference intervals of blood gas and acid-base analysis assays in China].

    PubMed

    Zhang, Lu; Wang, Wei; Wang, Zhiguo

    2015-10-01

    To investigate and analyze the upper and lower limits and their sources of reference intervals in blood gas and acid-base analysis assays. The data of reference intervals were collected, which come from the first run of 2014 External Quality Assessment (EQA) program in blood gas and acid-base analysis assays performed by National Center for Clinical Laboratories (NCCL). All the abnormal values and errors were eliminated. Data statistics was performed by SPSS 13.0 and Excel 2007 referring to upper and lower limits of reference intervals and sources of 7 blood gas and acid-base analysis assays, i.e. pH value, partial pressure of carbon dioxide (PCO2), partial pressure of oxygen (PO2), Na+, K+, Ca2+ and Cl-. Values were further grouped based on instrument system and the difference between each group were analyzed. There were 225 laboratories submitting the information on the reference intervals they had been using. The three main sources of reference intervals were National Guide to Clinical Laboratory Procedures [37.07% (400/1 079)], instructions of instrument manufactures [31.23% (337/1 079)] and instructions of reagent manufactures [23.26% (251/1 079)]. Approximately 35.1% (79/225) of the laboratories had validated the reference intervals they used. The difference of upper and lower limits in most assays among 7 laboratories was moderate, both minimum and maximum (i.e. the upper limits of pH value was 7.00-7.45, the lower limits of Na+ was 130.00-156.00 mmol/L), and mean and median (i.e. the upper limits of K+ was 5.04 mmol/L and 5.10 mmol/L, the upper limits of PCO2 was 45.65 mmHg and 45.00 mmHg, 1 mmHg = 0.133 kPa), as well as the difference in P2.5 and P97.5 between each instrument system group. It was shown by Kruskal-Wallis method that the P values of upper and lower limits of all the parameters were lower than 0.001, expecting the lower limits of Na+ with P value 0.029. It was shown by Mann-Whitney that the statistic differences were found among instrument

  17. Internal quality assurance in a clinical virology laboratory. II. Internal quality control.

    PubMed Central

    Gray, J J; Wreghitt, T G; McKee, T A; McIntyre, P; Roth, C E; Smith, D J; Sutehall, G; Higgins, G; Geraghty, R; Whetstone, R

    1995-01-01

    AIMS--In April 1991 additional quality control procedures were introduced into the virology section of the Clinical Microbiology and Public Health Laboratory, Cambridge. Internal quality control (IQC) samples were gradually included in the serological assays performed in the laboratory and supplemented kit controls and standard sera. METHODS--From April 1991 to December 1993, 2421 IQC procedures were carried out with reference sera. RESULTS--The IQC samples were evaluated according to the Westgard rules. Violations were recorded in 60 of 1808 (3.3%) controls and were highest in the IQC samples of complement fixation tests (25/312 (8%) of controls submitted for complement fixation tests). CONCLUSIONS--The inclusion of IQC samples in the serological assays performed in the laboratory has highlighted batch to batch variation in commercial assays. The setting of acceptable limits for the IQC samples has increased confidence in the validity of assay results. PMID:7730475

  18. Diagnostic performance of serological assays for anti-HBs testing: Results from a quality assessment program.

    PubMed

    Raven, Stijn; Hautvast, Jeannine; Steenbergen, Jim van; Akkermans, Reinier; Weykamp, Cas; Smits, Francis; Hoebe, Christian; Vossen, Ann

    2017-02-01

    Post-vaccination testing after hepatitis B vaccination is indispensable to evaluate long-term immunological protection. Using a threshold level of antibodies against hepatitis B surface antigen (anti-HBs) to define serological protection, implies reproducible and valid measurements of different diagnostic assays. In this study we assess the performance of currently used anti-HBs assays. In 2013, 45 laboratories participated in an external quality assessment program using pooled anti-HBs serum samples around the cutoff values 10IU/l and 100IU/l. Laboratories used either Axsym (Abbott Laboratories), Architect (Abbott Laboratories), Access (Beckman-Coulter), ADVIA Centaur anti-HBs2 (Siemens Healthcare Diagnostics), Elecsys, Modular or Cobas (Roche Diagnostics) or Vidas Total Quick (Biomerieux) for anti-HBs titre quantification. We analysed covariance using mixed-model repeated measures. To assess sensitivity/specificity and agreement, a true positive or true negative result was defined as an anti-HBs titre respectively above or below the cutoff value by ≥4 of 6 assays. Different anti-HBs assays were associated with statistically significant (P<0.05) differences in anti-HBs titres in all dilutions. Sensitivity and specificity ranged respectively from 64%-100% and 95%-100%. Agreement between assays around an anti-HBs titre cutoff value of 10IU/l ranged from 93%-100% and was 44% for a cutoff value of 100IU/l. Around a cutoff value of 10IU/l use of the Access assay may result in false-negative results. Concerning the cutoff value of 100IU/l, a sample being classified below or above this cutoff relied heavily on the specific assay used, with both the Architect and the Access resulting in false-negative results. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Development of a pan-rickettsial molecular diagnostic test based on recombinase polymerase amplification assay.

    PubMed

    Kissenkötter, Jonas; Hansen, Sören; Böhlken-Fascher, Susanne; Ademowo, Olusegun George; Oyinloye, Oladapo Elijah; Bakarey, Adeleye Solomon; Dobler, Gerhard; Tappe, Dennis; Patel, Pranav; Czerny, Claus-Peter; Abd El Wahed, Ahmed

    2018-03-01

    Rickettsioses are zoonotic vector-transmitted bacterial infections leading to flu-like symptoms and can progress to severe illness in humans. The gold standard for diagnosis of rickettsial infections is the indirect immunofluorescence assay, a serological method which is not suitable for pathogen identification during the acute phase of the disease. Therefore, several real-time PCR assays were developed. These assays are very sensitive, but require high-equipped laboratories and well-trained personnel. Hence, in this study, a rapid point-of-need detection method was developed to detect all Rickettsia species. The 23S and 16S rRNA genes were targeted to develop a recombinase polymerase amplification (RPA) assay. Both 23S and 16S_RPA assays required between seven to ten minutes to amplify and detect one or ten DNA molecules/reaction, respectively. The 16S_RPA assay detected all tested species, whereas the 23S_RPA assay identified only species of the spotted fever and transitional rickettsial groups. All results were compared with real-time PCR assays directed against the same rickettsial genes. The RPA assays are easy to handle and produced quicker results in comparison to real-time PCRs. Both RPA assays were implemented in a mobile suitcase laboratory to ease the use in rural areas. This method can help to provide rapid management of rickettsial infections. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Service impact of a change in HIV-1 viral load quantification assay.

    PubMed

    Tipple, Craig; Oomeer, Soonita; Dosekun, Olamide; Mackie, Nicola

    2014-01-01

    Due to discontinuation of the Siemens Versant HIV-1 RNA (bDNA) assay in the UK, our laboratory switched to the Roche Cobas Ampliprep/Taqman HIV-1 viral load (VL) assay (Roche) in April 2013. This assay has a lower cut-off of 20 RNA copies/mL (compared with <50 for the Siemens assay). Our laboratory demonstrated previously that a significant proportion (18%) of patients undetectable using bDNA HIV-1 RNA quantification exhibited low level viraemia (LLV) using the new assay. Local guidelines recommend that patients stable on therapy receive twice-yearly VLs. We evaluated the impact of the introduction of the new assay on our clinical service. A retrospective cohort analysis of treated patients with stable undetectable VL by bDNA (<50 copies/mL) followed by ≥ one low-level (<400 copies/mL) VL with the Roche assay. Demographic data were collected in addition to frequency of VL testing and genotypic resistance assays. Referrals to virtual clinic (VC) were recorded. Patients were identified using laboratory data and information collected from electronic patient records. RESULTS were analyzed with SPSS v18. One hundred and ninety patients were included. 79.5% male; 60.6% homosexual; mean age of 46 years. Duration on stable treatment was 46.35 (std. dev. 38.15) months. Current treatment regimens were 43.3% PI-based; 43.3% NNRTI-based and 13.7% other. Patients were stratified into VL 20-49 copies/mL (n=109); VL 50-199 copies/mL (n=71) and VL 200-399 copies/mL (n=10). In total, there were 471 VLs measured of which 274 were additional as a result of the assay switch. This resulted in six HIV-1 genotype requests and 16 VC discussions (Table 1). Longer duration on HAART was associated with reduced frequency of VL testing. The relative risk of ongoing detectability according to drug class are: PI 1.62 (95% CI 1.18-2.21); NNRTI 0.507 (95% CI 0.30-0.85) and other 1.09 (95% CI 0.48-2.43). Changes in assay can result in difficulties in interpretation of patient results. The assay

  1. Locked Nucleic Acid Probe-Based Real-Time PCR Assay for the Rapid Detection of Rifampin-Resistant Mycobacterium tuberculosis

    PubMed Central

    Sun, Chongyun; Li, Chao; Wang, Xiaochen; Liu, Haican; Zhang, Pingping; Zhao, Xiuqin; Wang, Xinrui; Jiang, Yi; Yang, Ruifu; Wan, Kanglin; Zhou, Lei

    2015-01-01

    Drug-resistant Mycobacterium tuberculosis can be rapidly diagnosed through nucleic acid amplification techniques by analyzing the variations in the associated gene sequences. In the present study, a locked nucleic acid (LNA) probe-based real-time PCR assay was developed to identify the mutations in the rpoB gene associated with rifampin (RFP) resistance in M. tuberculosis. Six LNA probes with the discrimination capability of one-base mismatch were designed to monitor the 23 most frequent rpoB mutations. The target mutations were identified using the probes in a “probe dropout” manner (quantification cycle = 0); thus, the proposed technique exhibited superiority in mutation detection. The LNA probe-based real-time PCR assay was developed in a two-tube format with three LNA probes and one internal amplification control probe in each tube. The assay showed excellent specificity to M. tuberculosis with or without RFP resistance by evaluating 12 strains of common non-tuberculosis mycobacteria. The limit of detection of M. tuberculosis was 10 genomic equivalents (GE)/reaction by further introducing a nested PCR method. In a blind validation of 154 clinical mycobacterium isolates, 142/142 (100%) were correctly detected through the assay. Of these isolates, 88/88 (100%) were determined as RFP susceptible and 52/54 (96.3%) were characterized as RFP resistant. Two unrecognized RFP-resistant strains were sequenced and were found to contain mutations outside the range of the 23 mutation targets. In conclusion, this study established a sensitive, accurate, and low-cost LNA probe-based assay suitable for a four-multiplexing real-time PCR instrument. The proposed method can be used to diagnose RFP-resistant tuberculosis in clinical laboratories. PMID:26599667

  2. The comet assay: Reflections on its development, evolution and applications.

    PubMed

    Singh, Narendra P

    2016-01-01

    The study of DNA damage and its repair is critical to our understanding of human aging and cancer. This review reflects on the development of a simple technique, now known as the comet assay, to study the accumulation of DNA damage and its repair. It describes my journey into aging research and the need for a method that sensitively quantifies DNA damage on a cell-by-cell basis and on a day-by-day basis. My inspirations, obstacles and successes on the path to developing this assay and improving its reliability and sensitivity are discussed. Recent modifications, applications, and the process of standardizing the technique are also described. What was once untried and unknown has become a technique used around the world for understanding and monitoring DNA damage. The comet assay's use has grown exponentially in the new millennium, as emphasis on studying biological phenomena at the single-cell level has increased. I and others have applied the technique across cell types (including germ cells) and species (including bacteria). As it enters new realms and gains clinical relevance, the comet assay may very well illuminate human aging and its prevention. Copyright © 2016. Published by Elsevier B.V.

  3. Single Laboratory Comparison of Quantitative Real-time PCR Assays for the Detection of Fecal Pollution

    EPA Science Inventory

    There are numerous quantitative real-time PCR (qPCR) assays available to detect and enumerate fecal pollution in ambient waters. Each assay employs distinct primers and probes that target different rRNA genes and microorganisms leading to potential variations in concentration es...

  4. Solution-Phase Synthesis of Dipeptides: A Capstone Project That Employs Key Techniques in an Organic Laboratory Course

    ERIC Educational Resources Information Center

    Marchetti, Louis; DeBoef, Brenton

    2015-01-01

    A contemporary approach to the synthesis and purification of several UV-active dipeptides has been developed for the second-year organic laboratory. This experiment exposes students to the important technique of solution-phase peptide synthesis and allows an instructor to highlight the parallel between what they are accomplishing in the laboratory…

  5. Comparison of two commercial carbapenemase gene confirmatory assays in multiresistant Enterobacteriaceae and Acinetobacter baumannii-complex.

    PubMed

    Rösner, Stephan; Gehlweiler, Kevin; Küsters, Uta; Kolbert, Mathias; Hübner, Kirsten; Pfennigwerth, Niels; Mack, Dietrich

    2018-01-01

    Multidrug-resistant Gram-negative bacilli (MDR-GNB) producing carbapenemases are increasing at an alarming speed. Rapid confirmation of carbapenemase type will be an important diagnostic step in clinical microbiology laboratories not only to reduce the risk of transmissions but also for optimising antibiotic therapy in the future. We compared diagnostic reliability of two commercially available molecular assays (Check-Direct CPE vs. AID line probe assay) for detection and typing of carbapenemase genes in 80 well-characterized isolates of MDR-GNB. Respective strains were isolated in various clinical specimens at our clinical microbiology laboratory. The reference standard included confirmation of carbapenemase-production at the molecular level at the German National Reference Laboratory for Multidrug-resistant Gram-negative bacteria (Ruhr-University Bochum, Germany). 53 Enterobacteriaceae and 27 members of the A. baumannii-complex were used in this study. The tested assays appeared highly reliable to confirm carbapenemase-producing Enterobacteriaceae (CPE) with respective sensitivities of 97.7%, but are currently unsuitable for analysis of members of the A. baumannii-complex. Both assays are easy to perform and rapid tools for confirmation and typing of the most common carbapenemase genes in Enterobacteriaceae. Implementation should be possible for any clinical microbiology laboratory with Check-Direct CPE being easier to handle and having less technological requirements.

  6. Diagnosis of Dengue Infection Using Conventional and Biosensor Based Techniques

    PubMed Central

    Parkash, Om; Hanim Shueb, Rafidah

    2015-01-01

    Dengue is an arthropod-borne viral disease caused by four antigenically different serotypes of dengue virus. This disease is considered as a major public health concern around the world. Currently, there is no licensed vaccine or antiviral drug available for the prevention and treatment of dengue disease. Moreover, clinical features of dengue are indistinguishable from other infectious diseases such as malaria, chikungunya, rickettsia and leptospira. Therefore, prompt and accurate laboratory diagnostic test is urgently required for disease confirmation and patient triage. The traditional diagnostic techniques for the dengue virus are viral detection in cell culture, serological testing, and RNA amplification using reverse transcriptase PCR. This paper discusses the conventional laboratory methods used for the diagnosis of dengue during the acute and convalescent phase and highlights the advantages and limitations of these routine laboratory tests. Subsequently, the biosensor based assays developed using various transducers for the detection of dengue are also reviewed. PMID:26492265

  7. International Network for Comparison of HIV Neutralization Assays: The NeutNet Report II

    PubMed Central

    Heyndrickx, Leo; Heath, Alan; Sheik-Khalil, Enas; Alcami, Jose; Bongertz, Vera; Jansson, Marianne; Malnati, Mauro; Montefiori, David; Moog, Christiane; Morris, Lynn; Osmanov, Saladin; Polonis, Victoria; Ramaswamy, Meghna; Sattentau, Quentin; Tolazzi, Monica; Schuitemaker, Hanneke; Willems, Betty; Wrin, Terri; Fenyö, Eva Maria; Scarlatti, Gabriella

    2012-01-01

    Background Neutralizing antibodies provide markers for vaccine-induced protective immunity in many viral infections. By analogy, HIV-1 neutralizing antibodies induced by immunization may well predict vaccine effectiveness. Assessment of neutralizing antibodies is therefore of primary importance, but is hampered by the fact that we do not know which assay(s) can provide measures of protective immunity. An international collaboration (NeutNet) involving 18 different laboratories previously compared different assays using monoclonal antibodies (mAbs) and soluble CD4 (Phase I study). Methods In the present study (Phase II), polyclonal reagents were evaluated by 13 laboratories. Each laboratory evaluated nine plasmas against an 8 virus panel representing different genetic subtypes and phenotypes. TriMab, a mixture of three mAbs, was used as a positive control allowing comparison of the results with Phase I in a total of nine different assays. The assays used either uncloned virus produced in peripheral blood mononuclear cells (PBMCs) (Virus Infectivity Assays, VIA), or Env (gp160)-pseudotyped viruses (pseudoviruses, PSV) produced in HEK293T cells from molecular clones or from uncloned virus. Target cells included PBMC and genetically engineered cell lines in either single- or multiple-cycle infection format. Infection was quantified by using a range of assay read-outs including extra- or intra-cellular p24 antigen detection, luciferase, beta-galactosidase or green fluorescent protein (GFP) reporter gene expression. Findings Using TriMab, results of Phase I and Phase II were generally in agreement for six of the eight viruses tested and confirmed that the PSV assay is more sensitive than PBMC (p = 0.014). Comparisons with the polyclonal reagents showed that sensitivities were dependent on both virus and plasma. Conclusions Here we further demonstrate clear differences in assay sensitivities that were dependent on both the neutralizing reagent and the virus

  8. International network for comparison of HIV neutralization assays: the NeutNet report II.

    PubMed

    Heyndrickx, Leo; Heath, Alan; Sheik-Khalil, Enas; Alcami, Jose; Bongertz, Vera; Jansson, Marianne; Malnati, Mauro; Montefiori, David; Moog, Christiane; Morris, Lynn; Osmanov, Saladin; Polonis, Victoria; Ramaswamy, Meghna; Sattentau, Quentin; Tolazzi, Monica; Schuitemaker, Hanneke; Willems, Betty; Wrin, Terri; Fenyö, Eva Maria; Scarlatti, Gabriella

    2012-01-01

    Neutralizing antibodies provide markers for vaccine-induced protective immunity in many viral infections. By analogy, HIV-1 neutralizing antibodies induced by immunization may well predict vaccine effectiveness. Assessment of neutralizing antibodies is therefore of primary importance, but is hampered by the fact that we do not know which assay(s) can provide measures of protective immunity. An international collaboration (NeutNet) involving 18 different laboratories previously compared different assays using monoclonal antibodies (mAbs) and soluble CD4 (Phase I study). In the present study (Phase II), polyclonal reagents were evaluated by 13 laboratories. Each laboratory evaluated nine plasmas against an 8 virus panel representing different genetic subtypes and phenotypes. TriMab, a mixture of three mAbs, was used as a positive control allowing comparison of the results with Phase I in a total of nine different assays. The assays used either uncloned virus produced in peripheral blood mononuclear cells (PBMCs) (Virus Infectivity Assays, VIA), or Env (gp160)-pseudotyped viruses (pseudoviruses, PSV) produced in HEK293T cells from molecular clones or from uncloned virus. Target cells included PBMC and genetically engineered cell lines in either single- or multiple-cycle infection format. Infection was quantified by using a range of assay read-outs including extra- or intra-cellular p24 antigen detection, luciferase, beta-galactosidase or green fluorescent protein (GFP) reporter gene expression. Using TriMab, results of Phase I and Phase II were generally in agreement for six of the eight viruses tested and confirmed that the PSV assay is more sensitive than PBMC (p = 0.014). Comparisons with the polyclonal reagents showed that sensitivities were dependent on both virus and plasma. Here we further demonstrate clear differences in assay sensitivities that were dependent on both the neutralizing reagent and the virus. Consistent with the Phase I study, we recommend

  9. Use of Bacteriophage MS2 as an Internal Control in Viral Reverse Transcription-PCR Assays

    PubMed Central

    Dreier, Jens; Störmer, Melanie; Kleesiek, Knut

    2005-01-01

    Diagnostic systems based on reverse transcription (RT)-PCR are widely used for the detection of viral genomes in different human specimens. The application of internal controls (IC) to monitor each step of nucleic acid amplification is necessary to prevent false-negative results due to inhibition or human error. In this study, we designed various real-time RT-PCRs utilizing the coliphage MS2 replicase gene, which differ in detection format, amplicon size, and efficiency of amplification. These noncompetitive IC assays, using TaqMan, hybridization probe, or duplex scorpion probe techniques, were tested on the LightCycler and Rotorgene systems. In our approach, clinical specimens were spiked with the control virus to monitor the efficiency of extraction, reverse transcription, and amplification steps. The MS2 RT-PCR assays were applied for internal control when using a second target hepatitis C virus RNA in duplex PCR in blood donor screening. The 95% detection limit was calculated by probit analysis to 44.9 copies per PCR (range, 38.4 to 73.4). As demonstrated routinely, application of MS2 IC assays exhibits low variability and can be applied in various RT-PCR assays. MS2 phage lysates were obtained under standard laboratory conditions. The quantification of phage and template RNA was performed by plating assays to determine PFU or via real-time RT-PCR. High stability of the MS2 phage preparations stored at −20°C, 4°C, and room temperature was demonstrated. PMID:16145106

  10. Mating competitiveness of sterile genetic sexing strain males (GAMA) under laboratory and semi-field conditions: Steps towards the use of the Sterile Insect Technique to control the major malaria vector Anopheles arabiensis in South Africa.

    PubMed

    Munhenga, Givemore; Brooke, Basil D; Gilles, Jeremie R L; Slabbert, Kobus; Kemp, Alan; Dandalo, Leonard C; Wood, Oliver R; Lobb, Leanne N; Govender, Danny; Renke, Marius; Koekemoer, Lizette L

    2016-03-02

    Anopheles arabiensis Patton is primarily responsible for malaria transmission in South Africa after successful suppression of other major vector species using indoor spraying of residual insecticides. Control of An. arabiensis using current insecticide based approaches is proving difficult owing to the development of insecticide resistance, and variable feeding and resting behaviours. The use of the sterile insect technique as an area-wide integrated pest management system to supplement the control of An. arabiensis was proposed for South Africa and is currently under investigation. The success of this technique is dependent on the ability of laboratory-reared sterile males to compete with wild males for mates. As part of the research and development of the SIT technique for use against An. arabiensis in South Africa, radio-sensitivity and mating competitiveness of a local An. arabiensis sexing strain were assessed. The optimal irradiation dose inducing male sterility without compromising mating vigour was tested using Cobalt 60 irradiation doses ranging from 70-100 Gy. Relative mating competitiveness of sterile laboratory-reared males (GAMA strain) compared to fertile wild-type males (AMAL strain) for virgin wild-type females (AMAL) was investigated under laboratory and semi-field conditions using large outdoor cages. Three different sterile male to fertile male to wild-type female ratios were evaluated [1:1:1, 5:1:1 and 10:1:1 (sterile males: fertile, wild-type males: fertile, wild-type females)]. Irradiation at the doses tested did not affect adult emergence but had a moderate effect on adult survivorship and mating vigour. A dose of 75 Gy was selected for the competitiveness assays. Mating competitiveness experiments showed that irradiated GAMA male mosquitoes are a third as competitive as their fertile AMAL counterparts under semi-field conditions. However, they were not as competitive under laboratory conditions. An inundative ratio of 10:1 induced the

  11. A novel curcumin assay with the metal ion Cu (II) as a simple probe by resonance light scattering technique

    NASA Astrophysics Data System (ADS)

    Chen, Zhanguang; Zhu, Li; Song, Tianhe; Chen, Junhui; Guo, Zhiming

    2009-04-01

    A fantastic resonance light scattering (RLS) enhancement phenomenon was found when the interaction between the metal ion Cu (II) and a natural antioxidant curcumin (C 21H 20O 6) occurred in certain conditions. Based on this phenomenon, a novel and convenient assay of curcumin was developed and successfully applied on the determination of curcumin in human urine samples. This assay applied the RLS technique with a common metal ion Cu (II) as the spectral probe. In the pH range of 6.5-7.5, the interaction between Cu (II) and curcumin occurred and the weak RLS intensity of Cu (II) was greatly enhanced by curcumin. The maximum peak was located at 538.5 nm. Under the optimum conditions, the enhanced RLS intensity was proportional to the concentration of curcumin ranging from 0.4 to 60 μg ml -1 with the detection limit of 0.07 μg ml -1. The synthetic and human urine samples were determined satisfactorily. Good recoveries (98.8-102.5%) were obtained in the determination of urine samples, which proved that the assay proposed was reliable and applicable in the determination of curcumin in body fluid. In this work, the RLS and fluorescence spectral characteristics of the chemicals, the optimum conditions of the reaction and the influencing factors were investigated.

  12. Key learnings from performance of the U.S. EPA Endocrine Disruptor Screening Program (EDSP) Tier 1 in vitro assays.

    PubMed

    LeBaron, Matthew J; Coady, Katie K; O'Connor, John C; Nabb, Diane L; Markell, Lauren K; Snajdr, Suzanne; Sue Marty, M

    2014-02-01

    Tier 1 of the U.S. EPA Endocrine Disruptor Screening Program comprises 11 studies: five in vitro assays, four in vivo mammalian assays, and two in vivo nonmammalian assays. The battery is designed to detect compounds with the potential to interact with the estrogen, androgen, or thyroid signaling pathways. This article examines the procedures, results, and data interpretation for the five Tier 1 in vitro assays: estrogen receptor (ER) and androgen receptor binding assays, an ER transactivation assay, an aromatase assay, and a steroidogenesis assay. Data are presented from two laboratories that have evaluated approximately 11 compounds in the Tier 1 in vitro assays. Generally, the ER and androgen receptor binding assays and the aromatase assay showed good specificity and reproducibility. As described in the guideline for the ER transactivation assay, a result is considered positive when the test compound induces a reporter gene signal that reaches 10% of the response seen with 1 nM 17β-estradiol (positive control). In the experience of these laboratories, this cutoff criterion may result in false-positive responses. For the steroidogenesis assay, there is variability in the basal and stimulated production of testosterone and estradiol by the H295R cells. This variability in responsiveness, coupled with potential cell stress at high concentrations of test compound, may make it difficult to discern whether hormone alterations are specific steroidogenesis alterations (i.e., endocrine active). Lastly, both laboratories had difficulty meeting some recommended performance criteria for each Tier 1 in vitro assay. Data with only minor deviations were deemed valid. © 2014 Wiley Periodicals, Inc.

  13. Gamma-ray imaging assay of cells 3-5 of the east cell line in the 235-F plutonium fuel form facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brand, A. D.; Aucott, T. J.; Diprete, D. P.

    In August and September, 2016, scientists from the Savannah River National Laboratory (SRNL) took a series of gamma-ray imaging measurements through the cell windows in front of Cells 3-5 on the east line of the Plutonium Fuel Form (PuFF) Facility using an electrically cooled, high-purity germanium detector. A Germanium Gamma Ray Imager (GeGI) was utilized since it allowed for the location from which the radiation was being emitted to be identified by incoming gamma-ray energy. This measurement technique provided a tool which allowed for the relative concentration of Pu-238 to be mapped throughout each cell. The mapping and new assaymore » data were then used to update the model used in an assay discussed in a 2014 report (SRNL-STI-2014-00629) and to calculate a more accurate value for the holdup in each of the cells [1]. Note that the mapping and new assay data did not replace the previous assay data in the model. Rather, the mapping and new assay data provided additional details on source distribution, which supplemented the previous assay data.« less

  14. Validation of the 3D Skin Comet assay using full thickness skin models: Transferability and reproducibility.

    PubMed

    Reisinger, Kerstin; Blatz, Veronika; Brinkmann, Joep; Downs, Thomas R; Fischer, Anja; Henkler, Frank; Hoffmann, Sebastian; Krul, Cyrille; Liebsch, Manfred; Luch, Andreas; Pirow, Ralph; Reus, Astrid A; Schulz, Markus; Pfuhler, Stefan

    2018-03-01

    Recently revised OECD Testing Guidelines highlight the importance of considering the first site-of-contact when investigating the genotoxic hazard. Thus far, only in vivo approaches are available to address the dermal route of exposure. The 3D Skin Comet and Reconstructed Skin Micronucleus (RSMN) assays intend to close this gap in the in vitro genotoxicity toolbox by investigating DNA damage after topical application. This represents the most relevant route of exposure for a variety of compounds found in household products, cosmetics, and industrial chemicals. The comet assay methodology is able to detect both chromosomal damage and DNA lesions that may give rise to gene mutations, thereby complementing the RSMN which detects only chromosomal damage. Here, the comet assay was adapted to two reconstructed full thickness human skin models: the EpiDerm™- and Phenion ® Full-Thickness Skin Models. First, tissue-specific protocols for the isolation of single cells and the general comet assay were transferred to European and US-American laboratories. After establishment of the assay, the protocol was then further optimized with appropriate cytotoxicity measurements and the use of aphidicolin, a DNA repair inhibitor, to improve the assay's sensitivity. In the first phase of an ongoing validation study eight chemicals were tested in three laboratories each using the Phenion ® Full-Thickness Skin Model, informing several validation modules. Ultimately, the 3D Skin Comet assay demonstrated a high predictive capacity and good intra- and inter-laboratory reproducibility with four laboratories reaching a 100% predictivity and the fifth yielding 70%. The data are intended to demonstrate the use of the 3D Skin Comet assay as a new in vitro tool for following up on positive findings from the standard in vitro genotoxicity test battery for dermally applied chemicals, ultimately helping to drive the regulatory acceptance of the assay. To expand the database, the validation will

  15. Serological assays based on recombinant viral proteins for the diagnosis of arenavirus hemorrhagic fevers.

    PubMed

    Fukushi, Shuetsu; Tani, Hideki; Yoshikawa, Tomoki; Saijo, Masayuki; Morikawa, Shigeru

    2012-10-12

    The family Arenaviridae, genus Arenavirus, consists of two phylogenetically independent groups: Old World (OW) and New World (NW) complexes. The Lassa and Lujo viruses in the OW complex and the Guanarito, Junin, Machupo, Sabia, and Chapare viruses in the NW complex cause viral hemorrhagic fever (VHF) in humans, leading to serious public health concerns. These viruses are also considered potential bioterrorism agents. Therefore, it is of great importance to detect these pathogens rapidly and specifically in order to minimize the risk and scale of arenavirus outbreaks. However, these arenaviruses are classified as BSL-4 pathogens, thus making it difficult to develop diagnostic techniques for these virus infections in institutes without BSL-4 facilities. To overcome these difficulties, antibody detection systems in the form of an enzyme-linked immunosorbent assay (ELISA) and an indirect immunofluorescence assay were developed using recombinant nucleoproteins (rNPs) derived from these viruses. Furthermore, several antigen-detection assays were developed. For example, novel monoclonal antibodies (mAbs) to the rNPs of Lassa and Junin viruses were generated. Sandwich antigen-capture (Ag-capture) ELISAs using these mAbs as capture antibodies were developed and confirmed to be sensitive and specific for detecting the respective arenavirus NPs. These rNP-based assays were proposed to be useful not only for an etiological diagnosis of VHFs, but also for seroepidemiological studies on VHFs. We recently developed arenavirus neutralization assays using vesicular stomatitis virus (VSV)-based pseudotypes bearing arenavirus recombinant glycoproteins. The goal of this article is to review the recent advances in developing laboratory diagnostic assays based on recombinant viral proteins for the diagnosis of VHFs and epidemiological studies on the VHFs caused by arenaviruses.

  16. Identification of six Listeria species by real-time PCR assay.

    PubMed

    Hage, E; Mpamugo, O; Ohai, C; Sapkota, S; Swift, C; Wooldridge, D; Amar, C F L

    2014-06-01

    The Listeria genus comprises 10 recognized species. Listeria monocytogenes causes listeriosis in humans and other animals primarily via contaminated food or animal feed. Listeria ivanovii causes listeriosis in animals and on rare occasions in humans. The identification of nonpathogenic species of Listeria in foods indicates that conditions exist that support the growth of pathogenic strains and is used to facilitate the implementation of control and prevention measures. This study shows the development and evaluation of a 5'exonuclease real-time PCR assay for the rapid identification of Listeria seeligeri, Listeria welshimeri, L. monocytogenes, L. ivanovii, Listeria grayi and Listeria innocua. The assay consists of two triplexes that were evaluated using 53 cultures of Gram-positive bacteria, including 49 Listeria spp. from human, animal, food or food-processing environments. The assay was rapid, specific and reproducible and could identify each of the six species from a mixture of strains. The developed assay proved to be a powerful means of rapidly identifying Listeria species and could be usefully implemented in busy specialist reference laboratories. The identification of species of Listeria from foods is important to monitor pathogenic strains and facilitates the implementation of control measures. This study shows the development and evaluation of a 5'exonuclease real-time PCR assay for the rapid identification of L. seeligeri, L. welshimeri, L. monocytogenes and L. ivanovii, L. grayi, L. innocua. The developed assay proved to be specific, rapid and reproducible and therefore could be implemented in busy specialist reference laboratories. © 2014 The Society for Applied Microbiology.

  17. Development of real-time recombinase polymerase amplification assay for rapid and sensitive detection of canine parvovirus 2.

    PubMed

    Geng, Yunyun; Wang, Jianchang; Liu, Libing; Lu, Yan; Tan, Ke; Chang, Yan-Zhong

    2017-11-06

    Canine parvovirus 2, a linear single-stranded DNA virus belonging to the genus Parvovirus within the family Parvoviridae, is a highly contagious pathogen of domestic dogs and several wild canidae species. Early detection of canine parvovirus (CPV-2) is crucial to initiating appropriate outbreak control strategies. Recombinase polymerase amplification (RPA), a novel isothermal gene amplification technique, has been developed for the molecular detection of diverse pathogens. In this study, a real-time RPA assay was developed for the detection of CPV-2 using primers and an exo probe targeting the CPV-2 nucleocapsid protein gene. The real-time RPA assay was performed successfully at 38 °C, and the results were obtained within 4-12 min for 10 5 -10 1 molecules of template DNA. The assay only detected CPV-2, and did not show cross-detection of other viral pathogens, demonstrating a high level of specificity. The analytical sensitivity of the real-time RPA was 10 1 copies/reaction of a standard DNA template, which was 10 times more sensitive than the common RPA method. The clinical sensitivity of the real-time RPA assay matched 100% (n = 91) to the real-time PCR results. The real-time RPA assay is a simple, rapid, reliable and affordable method that can potentially be applied for the detection of CPV-2 in the research laboratory and point-of-care diagnosis.

  18. Comparison of estrogen receptor results from pathology reports with results from central laboratory testing.

    PubMed

    Collins, Laura C; Marotti, Jonathan D; Baer, Heather J; Tamimi, Rulla M

    2008-02-06

    We compared estrogen receptor (ER) assay results abstracted from pathology reports with ER results determined on the same specimens by a central laboratory with an immunohistochemical assay. Paraffin sections were cut from tissue microarrays containing 3093 breast cancer specimens from women enrolled in the Nurses' Health Study, 1851 of which had both pathology reports and tissue available for central laboratory testing. All sections were immunostained for ER at the same time. The original assays were biochemical for 1512 (81.7%) of the 1851 specimens, immunohistochemical for 336 (18.2%), and immunofluorescent for three (0.2%). ER results from pathology reports and repeat central laboratory testing were in agreement for 87.3% of specimens (1615 of the 1851 specimens; kappa statistic = 0.64, P < .001). When the comparison was restricted to the specimens for which the ER assays were originally performed by immunohistochemistry, the agreement rate increased to 92.3% of specimens (310 of the 336 specimens; kappa statistic = 0.78, P < .001). Thus, ER assay results from pathology reports appear to be a reasonable alternative to central laboratory ER testing for large, population-based studies of patients with breast cancer.

  19. The comet assay: ready for 30 more years.

    PubMed

    Møller, Peter

    2018-02-24

    During the last 30 years, the comet assay has become widely used for the measurement of DNA damage and repair in cells and tissues. A landmark achievement was reached in 2016 when the Organization for Economic Co-operation and Development adopted a comet assay guideline for in vivo testing of DNA strand breaks in animals. However, the comet assay has much more to offer than being an assay for testing DNA strand breaks in animal organs. The use of repair enzymes increases the range of DNA lesions that can be detected with the assay. It can also be modified to measure DNA repair activity. Still, despite the long-term use of the assay, there is a need for studies that assess the impact of variation in specific steps of the procedure. This is particularly important for the on-going efforts to decrease the variation between experiments and laboratories. The articles in this Special Issue of Mutagenesis cover important technical issues of the comet assay procedure, nanogenotoxicity and ionising radiation sensitivity on plant cells. The included biomonitoring studies have assessed seasonal variation and certain predictors for the basal level of DNA damage in white blood cells. Lastly, the comet assay has been used in studies on genotoxicity of environmental and occupational exposures in human biomonitoring studies and animal models. Overall, the articles in this Special Issue demonstrate the versatility of the comet assay and they hold promise that the assay is ready for the next 30 years.

  20. Quantification of OH and HO2 radicals during the low-temperature oxidation of hydrocarbons by Fluorescence Assay by Gas Expansion technique

    PubMed Central

    Blocquet, Marion; Schoemaecker, Coralie; Amedro, Damien; Herbinet, Olivier; Battin-Leclerc, Frédérique; Fittschen, Christa

    2013-01-01

    •OH and •HO2 radicals are known to be the key species in the development of ignition. A direct measurement of these radicals under low-temperature oxidation conditions (T = 550–1,000 K) has been achieved by coupling a technique named fluorescence assay by gas expansion, an experimental technique designed for the quantification of these radicals in the free atmosphere, to a jet-stirred reactor, an experimental device designed for the study of low-temperature combustion chemistry. Calibration allows conversion of relative fluorescence signals to absolute mole fractions. Such radical mole fraction profiles will serve as a benchmark for testing chemical models developed to improve the understanding of combustion processes. PMID:24277836

  1. Certification of the Uranium Isotopic Ratios in Nbl Crm 112-A, Uranium Assay Standard (Invited)

    NASA Astrophysics Data System (ADS)

    Mathew, K. J.; Mason, P.; Narayanan, U.

    2010-12-01

    Isotopic reference materials are needed to validate measurement procedures and to calibrate multi-collector ion counting detector systems. New Brunswick Laboratory (NBL) provides a suite of certified isotopic and assay standards for the US and international nuclear safeguards community. NBL Certified Reference Material (CRM) 112-A Uranium Metal Assay Standard with a consensus value of 137.88 for the 238U/235U ratio [National Bureau of Standards -- NBS, currently named National Institute for Standards and Technology, Standard Reference Material (SRM) 960 had been renamed CRM 112-A] is commonly used as a natural uranium isotopic reference material within the earth science community. We have completed the analytical work for characterizing the isotopic composition of NBL CRM 112-A Uranium Assay Standard and NBL CRM 145 (uranyl nitrate solution prepared from CRM 112-A). The 235U/238U isotopic ratios were characterized using the total evaporation (TE) and the modified total evaporation (MTE) methods. The 234U/238U isotope ratios were characterized using a conventional analysis technique and verified using the ratios measured in the MTE analytical technique. The analysis plan for the characterization work was developed such that isotopic ratios that are traceable to NBL CRM U030-A are obtained. NBL is preparing a certificate of Analysis and will issue a certificate for Uranium Assay and Isotopics. The results of the CRM 112-A certification measurements will be discussed. These results will be compared with the average values from Richter et al (2010). A comparison of the precision and accuracy of the measurement methods (TE, MTE and Conventional) employed in the certification will be presented. The uncertainties in the 235U/238U and 234U/238U ratios, calculated according to the Guide to the Expression of Uncertainty in Measurements (GUM) and the dominant contributors to the combined standard uncertainty will be discussed.

  2. Efficacy of alkyl dimethyl benzyl ammonium chloride on suppression of Physalospora vaccinii in laboratory assays.

    PubMed

    Tubajika, K M

    2006-10-01

    Growth of Physalospora vaccinii on inoculated agar growth medium and cranberries treated with 0.1, 1, 10, 100, and 1,000 ppm of alkyl dimethyl benzyl ammonium chloride (ADBAC) was investigated in the laboratory. In vitro growth assays, the colony diameter, and mycelial dry weight of P. vaccinii was reduced at 1,000 ppm ADBAC. Mild or no reduction of fungal growth and mycelial dry weight was observed at concentrations less than 100 ppm when compared with the nonamended control. Growth of P. vaccinii on inoculated cranberries was inhibited by treatment with 10 and 100 ppm ADBAC. Complete inhibition of fungus growth was also achieved at 1,000 ppm ADBAC. Area under the disease progress curve values in wounded fruits were 75, 77, and 100% at 10, 100, and 1,000 ppm ADBAC, respectively, whereas area under the disease progress curve values in fruits immersed in ADBAC and pathogen were reduced 47 to 100% compared with the untreated fruits used as controls. No P. vaccinii or other fungi were detected on the control fruits inoculated with sterile distilled water. This is the first report on the use of ADBAC to control a field and storage rotting fungus, P. vaccinii. ADBAC is likely to be an important component to any integrated approach for reducing the risks associated with the presence of pathogenic microorganisms in or on foods.

  3. Toward development of a comprehensive external quality assurance program for polyfunctional intracellular cytokine staining assays

    PubMed Central

    Staats, Janet S.; Enzor, Jennifer H.; Sanchez, Ana M.; Rountree, Wes; Chan, Cliburn; Jaimes, Maria; Chan, Ray Chun-Fai; Gaur, Amitabh; Denny, Thomas N.; Weinhold, Kent J.

    2014-01-01

    The External Quality Assurance Program Oversight Laboratory (EQAPOL) Flow Cytometry Program assesses the proficiency of NIH/NIAID/DAIDS-supported and potentially other interested research laboratories in performing Intracellular Cytokine Staining (ICS) assays. The goal of the EQAPOL Flow Cytometry External Quality Assurance Program (EQAP) is to provide proficiency testing and remediation for participating sites. The program is not punitive; rather, EQAPOL aims to help sites identify areas for improvement. EQAPOL utilizes a highly standardized ICS assay to minimize variability and readily identify those sites experiencing technical difficulties with their assays. Here, we report the results of External Proficiency 3 (EP3) where participating sites performed a 7-color ICS assay. On average, sites perform well in the Flow Cytometry EQAP (median score is “Good”). The most common technical issues identified by the program involve protocol adherence and data analysis; these areas have been the focus of site remediation. The EQAPOL Flow Cytometry team is now in the process of expanding the program to 8-color ICS assays. Evaluating polyfunctional ICS responses would align the program with assays currently being performed in support of HIV immune monitoring assays. PMID:24968072

  4. Effect of Fungal Competition on Decay Rates in Bicultured Soil Bottle Assays

    Treesearch

    Grant T. Kirker; Amy Blodgett; Patricia K. Lebow; Carol A. Clausen

    2016-01-01

    For decades, wood scientists and preservative formulators have employed the monocultured soil bottle assay to test efficacy of wood treatment in the laboratory as a rapid predictor of field performance. This study examines the effects of bicultured soil bottle assays on the decay by common wood decay fungi. Mycelial interactions were noted in early stages of...

  5. Cytotoxicity assay automation

    NASA Technical Reports Server (NTRS)

    Levinthal, E. C.; Payne, R. O.

    1971-01-01

    The design and construction of a system to automatically test HLP antigens are described. Major efforts were made to test and evaluate the performance of such a system, and compare its performance with nonautomatic tissue typing techniques. The system is based on the fluorochromatic cytotoxicity assay. Results show the system will work but is subject to malfunctions after a few samplings, and poses problems in showing correctly the necessary readings.

  6. Effectiveness of Student-Generated Video as a Teaching Tool for an Instrumental Technique in the Organic Chemistry Laboratory

    ERIC Educational Resources Information Center

    Jordan, Jeremy T.; Box, Melinda C.; Eguren, Kristen E.; Parker, Thomas A.; Saraldi-Gallardo, Victoria M.; Wolfe, Michael I.; Gallardo-Williams, Maria T.

    2016-01-01

    Multimedia instruction has been shown to serve as an effective learning aid for chemistry students. In this study, the viability of student-generated video instruction for organic chemistry laboratory techniques and procedure was examined and its effectiveness compared to instruction provided by a teaching assistant (TA) was evaluated. After…

  7. Laboratory insights into the detection of surface biosignatures by remote-sensing techniques

    NASA Astrophysics Data System (ADS)

    Poch, O.; Pommerol, A.; Jost, B.; Roditi, I.; Frey, J.; Thomas, N.

    2014-03-01

    With the progress of direct imaging techniques, it will be possible in the short or long-term future to retrieve more efficiently the information on the physical properties of the light reflected by rocky exoplanets (Traub et al., 2010). The search for visible-infrared absorption bands of peculiar gases (O2, CH4 etc.) in this light could give clues for the presence of life (Kaltenegger and Selsis, 2007). Even more uplifting would be the direct detection of life itself, on the surface of an exoplanet. Considering this latter possibility, what is the potential of optical remote-sensing methods to detect surface biosignatures? Reflected light from the surface of the Earth exhibits a strong surface biosignature in the form of an abrupt change of reflectance between the visible and infrared range of the spectrum (Seager et al., 2005). This spectral feature called "vegetation red-edge" is possibly the consequence of biological evolution selecting the right chemical structures enabling the plants to absorb the visible energy, while preventing them from overheating by reflecting more efficiently the infrared. Such red-edge is also found in primitive photosynthetic bacteria, cyanobacteria, that colonized the surface of the Earth ocean and continents billions of years before multicellular plants (Knacke, 2003). If life ever arose on an Earth-like exoplanet, one could hypothesize that some form of its surface-life evolves into similar photo-active organisms, also exhibiting a red-edge. In this paper, we will present our plan and preliminary results of a laboratory study aiming at precising the potentiality of remote sensing techniques in detecting such surface biosignatures. Using equipment that has been developed in our team for surface photometry studies (Pommerol 2011, Jost 2013, Pommerol 2013), we will investigate the reflectance spectra and bidirectional reflectance function of soils containing bacteria such as cyanobacteria, in various environmental conditions. We will

  8. Widespread Nanoparticle-Assay Interference: Implications for Nanotoxicity Testing

    PubMed Central

    Ong, Kimberly J.; MacCormack, Tyson J.; Clark, Rhett J.; Ede, James D.; Ortega, Van A.; Felix, Lindsey C.; Dang, Michael K. M.; Ma, Guibin; Fenniri, Hicham; Veinot, Jonathan G. C.; Goss, Greg G.

    2014-01-01

    The evaluation of engineered nanomaterial safety has been hindered by conflicting reports demonstrating differential degrees of toxicity with the same nanoparticles. The unique properties of these materials increase the likelihood that they will interfere with analytical techniques, which may contribute to this phenomenon. We tested the potential for: 1) nanoparticle intrinsic fluorescence/absorbance, 2) interactions between nanoparticles and assay components, and 3) the effects of adding both nanoparticles and analytes to an assay, to interfere with the accurate assessment of toxicity. Silicon, cadmium selenide, titanium dioxide, and helical rosette nanotubes each affected at least one of the six assays tested, resulting in either substantial over- or under-estimations of toxicity. Simulation of realistic assay conditions revealed that interference could not be predicted solely by interactions between nanoparticles and assay components. Moreover, the nature and degree of interference cannot be predicted solely based on our current understanding of nanomaterial behaviour. A literature survey indicated that ca. 95% of papers from 2010 using biochemical techniques to assess nanotoxicity did not account for potential interference of nanoparticles, and this number had not substantially improved in 2012. We provide guidance on avoiding and/or controlling for such interference to improve the accuracy of nanotoxicity assessments. PMID:24618833

  9. Laboratory Reptile Surgery: Principles and Techniques

    PubMed Central

    Alworth, Leanne C; Hernandez, Sonia M; Divers, Stephen J

    2011-01-01

    Reptiles used for research and instruction may require surgical procedures, including biopsy, coelomic device implantation, ovariectomy, orchidectomy, and esophogostomy tube placement, to accomplish research goals. Providing veterinary care for unanticipated clinical problems may require surgical techniques such as amputation, bone or shell fracture repair, and coeliotomy. Although many principles of surgery are common between mammals and reptiles, important differences in anatomy and physiology exist. Veterinarians who provide care for these species should be aware of these differences. Most reptiles undergoing surgery are small and require specific instrumentation and positioning. In addition, because of the wide variety of unique physiologic and anatomic characteristics among snakes, chelonians, and lizards, different techniques may be necessary for different reptiles. This overview describes many common reptile surgery techniques and their application for research purposes or to provide medical care to research subjects. PMID:21333158

  10. Laboratory reptile surgery: principles and techniques.

    PubMed

    Alworth, Leanne C; Hernandez, Sonia M; Divers, Stephen J

    2011-01-01

    Reptiles used for research and instruction may require surgical procedures, including biopsy, coelomic device implantation, ovariectomy, orchidectomy, and esophogostomy tube placement, to accomplish research goals. Providing veterinary care for unanticipated clinical problems may require surgical techniques such as amputation, bone or shell fracture repair, and coeliotomy. Although many principles of surgery are common between mammals and reptiles, important differences in anatomy and physiology exist. Veterinarians who provide care for these species should be aware of these differences. Most reptiles undergoing surgery are small and require specific instrumentation and positioning. In addition, because of the wide variety of unique physiologic and anatomic characteristics among snakes, chelonians, and lizards, different techniques may be necessary for different reptiles. This overview describes many common reptile surgery techniques and their application for research purposes or to provide medical care to research subjects.

  11. Blood collection tubes as medical devices: The potential to affect assays and proposed verification and validation processes for the clinical laboratory.

    PubMed

    Bowen, Raffick A R; Adcock, Dorothy M

    2016-12-01

    Blood collection tubes (BCTs) are an often under-recognized variable in the preanalytical phase of clinical laboratory testing. Unfortunately, even the best-designed and manufactured BCTs may not work well in all clinical settings. Clinical laboratories, in collaboration with healthcare providers, should carefully evaluate BCTs prior to putting them into clinical use to determine their limitations and ensure that patients are not placed at risk because of inaccuracies due to poor tube performance. Selection of the best BCTs can be achieved through comparing advertising materials, reviewing the literature, observing the device at a scientific meeting, receiving a demonstration, evaluating the device under simulated conditions, or testing the device with patient samples. Although many publications have discussed method validations, few detail how to perform experiments for tube verification and validation. This article highlights the most common and impactful variables related to BCTs and discusses the validation studies that a typical clinical laboratory should perform when selecting BCTs. We also present a brief review of how in vitro diagnostic devices, particularly BCTs, are regulated in the United States, the European Union, and Canada. The verification and validation of BCTs will help to avoid the economic and human costs associated with incorrect test results, including poor patient care, unnecessary testing, and delays in test results. We urge laboratorians, tube manufacturers, diagnostic companies, and other researchers to take all the necessary steps to protect against the adverse effects of BCT components and their additives on clinical assays. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  12. Measuring molecular biomarkers in epidemiologic studies: laboratory techniques and biospecimen considerations.

    PubMed

    Erickson, Heidi S

    2012-09-28

    The future of personalized medicine depends on the ability to efficiently and rapidly elucidate a reliable set of disease-specific molecular biomarkers. High-throughput molecular biomarker analysis methods have been developed to identify disease risk, diagnostic, prognostic, and therapeutic targets in human clinical samples. Currently, high throughput screening allows us to analyze thousands of markers from one sample or one marker from thousands of samples and will eventually allow us to analyze thousands of markers from thousands of samples. Unfortunately, the inherent nature of current high throughput methodologies, clinical specimens, and cost of analysis is often prohibitive for extensive high throughput biomarker analysis. This review summarizes the current state of high throughput biomarker screening of clinical specimens applicable to genetic epidemiology and longitudinal population-based studies with a focus on considerations related to biospecimens, laboratory techniques, and sample pooling. Copyright © 2012 John Wiley & Sons, Ltd.

  13. Procedures and equipment for staining large numbers of plant root samples for endomycorrhizal assay.

    PubMed

    Kormanik, P P; Bryan, W C; Schultz, R C

    1980-04-01

    A simplified method of clearing and staining large numbers of plant roots for vesicular-arbuscular (VA) mycorrhizal assay is presented. Equipment needed for handling multiple samples is described, and two formulations for the different chemical solutions are presented. Because one formulation contains phenol, its use should be limited to basic studies for which adequate laboratory exhaust hoods are available and great clarity of fungal structures is required. The second staining formulation, utilizing lactic acid instead of phenol, is less toxic, requires less elaborate laboratory facilities, and has proven to be completely satisfactory for VA assays.

  14. An in-house assay for BK polyomavirus quantification using the Abbott m2000 RealTime system.

    PubMed

    Muldrew, Kenneth L; Lovett, Jennie L

    2013-11-01

    BK polyomavirus (BKPyV) quantification is useful for monitoring renal transplant patient response to therapy. The Abbott m2000 RealTime System employed by some clinical laboratories to perform US Food and Drug Administration-approved assays can also be used to develop in-house assays such as the one presented here. This study aimed to validate an in-house quantitative real-time PCR assay targeting the BKPyV major capsid VP1 gene for assessment of viral load using the Abbott m2000 RealTime System. BKPyV load was measured in 95 urine and plasma samples previously tested for BKPyV by one of three laboratories (46 BKPyV-positive samples consisting of 35 plasma and 11 urine samples; 49 samples negative for BKPyV consisting of 47 plasma and two urine samples). Two additional plasma specimens from the College of American Pathologists proficiency testing survey were also analysed. Precision studies were performed by diluting a high-viral-titre patient sample into BKPyV-negative pooled plasma to create high-positive (6.16 log10 copies ml(-1)) and low-positive (3.16 log10 copies ml(-1)) samples. For precision studies of inter-assay variability, a high-positive (7.0 log10 copies ml(-1)) and a low-positive (3.0 log10 copies ml(-1)) sample were measured in 20 separate runs. The assay's limit of quantification and limit of detection were 2.70 and 2.25 log10 copies ml(-1), respectively. The assay was linear from 2.70 to 9.26 log10 copies ml(-1). Of the 48 known positives, 43 were detected as positive, with three reported by the reference laboratory as values lower than the limit of detection. Two known positives at 3.27 and 3.80 log10 copies ml(-1) tested negative by the m2000 BKPyV assay. Of the 49 known negative samples, 48 were negative by the m2000 BKPyV load assay, with one sample confirmed positive by a reference laboratory. Qualitative analysis prior to discrepancy testing demonstrated a sensitivity of 89.58 % and a specificity of 97.96 %. Precision studies

  15. The role of the independent clinical laboratory in new assay development and commercialization.

    PubMed

    Ellis, David G

    2003-01-01

    Most would agree that these are exciting times in the field of laboratory medicine. As the body of scientific knowledge expands and research activities, such as those catalyzed by the sequencing of the human genome, bring us closer to the promise of personalized medicine, the clinical laboratory industry will have increasing opportunities to partner with owners of intellectual property to develop and commercialize new diagnostic tests. The large, independent clinical laboratories are particularly well positioned to commercialize important new tests, with their broad market penetration, infrastructure, and the scale to run esoteric tests cost-effectively.

  16. A novel duplex real-time reverse transcriptase-polymerase chain reaction assay for the detection of hepatitis C viral RNA with armored RNA as internal control

    PubMed Central

    2010-01-01

    Background The hepatitis C virus (HCV) genome is extremely heterogeneous. Several HCV infections can not be detected using currently available commercial assays, probably because of mismatches between the template and primers/probes. By aligning the HCV sequences, we developed a duplex real-time reverse transcriptase-polymerase chain reaction (RT-PCR) assay using 2 sets of primers/probes and a specific armored RNA as internal control. The 2 detection probes were labelled with the same fluorophore, namely, 6-carboxyfluorescein (FAM), at the 5' end; these probes could mutually combine, improving the power of the test. Results The limit of detection of the duplex primer/probe assay was 38.99 IU/ml. The sensitivity of the assay improved significantly, while the specificity was not affected. All HCV genotypes in the HCV RNA Genotype Panel for Nucleic Acid Amplification Techniques could be detected. In the testing of 109 serum samples, the performance of the duplex real-time RT-PCR assay was identical to that of the COBAS AmpliPrep (CAP)/COBAS TaqMan (CTM) assay and superior to 2 commercial HCV assay kits. Conclusions The duplex real-time RT-PCR assay is an efficient and effective viral assay. It is comparable with the CAP/CTM assay with regard to the power of the test and is appropriate for blood-donor screening and laboratory diagnosis of HCV infection. PMID:20529244

  17. Scientific Communication and the Unified Laboratory Sequence1

    NASA Astrophysics Data System (ADS)

    Silverstein, Todd P.; Hudak, Norman J.; Chapple, Frances H.; Goodney, David E.; Brink, Christina P.; Whitehead, Joyce P.

    1997-02-01

    The "Temperature Dependent Relaxation Kinetics" lab was first implemented in 1987; it uses stopped-flow pH jump techniques to determine rate constants and activation parameters (H, S, G) for a reaction mechanism. Two new experiments (Monoamine Oxidase, and Molecular Modeling) will be implemented in the fall of 1997. The "Monoamine Oxidase" project uses chromatography and spectrophotometry to purify and characterize the enzyme. Subsequent photometric assays explore the enzyme's substrate specificity, activation energy, and denaturation. Finally, in the "Molecular Modeling"project, students characterize enzyme - substrate and drug - receptor interactions. Energy minimization protocols are used to make predictions about protein structure and ligand binding, and to explore pharmacological and biomedical implications. With these additions, the twelve Unified Laboratory projects introduce our chemistry majors to nearly all of the instrumental methods commonly encountered in modern chemistry.

  18. The Case for Laboratory Developed Procedures

    PubMed Central

    Sabatini, Linda M.; Tsongalis, Gregory J.; Caliendo, Angela M.; Olsen, Randall J.; Ashwood, Edward R.; Bale, Sherri; Benirschke, Robert; Carlow, Dean; Funke, Birgit H.; Grody, Wayne W.; Hayden, Randall T.; Hegde, Madhuri; Lyon, Elaine; Pessin, Melissa; Press, Richard D.; Thomson, Richard B.

    2017-01-01

    An explosion of knowledge and technology is revolutionizing medicine and patient care. Novel testing must be brought to the clinic with safety and accuracy, but also in a timely and cost-effective manner, so that patients can benefit and laboratories can offer testing consistent with current guidelines. Under the oversight provided by the Clinical Laboratory Improvement Amendments, laboratories have been able to develop and optimize laboratory procedures for use in-house. Quality improvement programs, interlaboratory comparisons, and the ability of laboratories to adjust assays as needed to improve results, utilize new sample types, or incorporate new mutations, information, or technologies are positive aspects of Clinical Laboratory Improvement Amendments oversight of laboratory-developed procedures. Laboratories have a long history of successful service to patients operating under Clinical Laboratory Improvement Amendments. A series of detailed clinical examples illustrating the quality and positive impact of laboratory-developed procedures on patient care is provided. These examples also demonstrate how Clinical Laboratory Improvement Amendments oversight ensures accurate, reliable, and reproducible testing in clinical laboratories. PMID:28815200

  19. Verification of performance specifications for a US Food and Drug Administration-approved molecular microbiology test: Clostridium difficile cytotoxin B using the Becton, Dickinson and Company GeneOhm Cdiff assay.

    PubMed

    Schlaberg, Robert; Mitchell, Michael J; Taggart, Edward W; She, Rosemary C

    2012-01-01

    US Food and Drug Administration (FDA)-approved diagnostic tests based on molecular genetic technologies are becoming available for an increasing number of microbial pathogens. Advances in technology and lower costs have moved molecular diagnostic tests formerly performed for research purposes only into much wider use in clinical microbiology laboratories. To provide an example of laboratory studies performed to verify the performance of an FDA-approved assay for the detection of Clostridium difficile cytotoxin B compared with the manufacturer's performance standards. We describe the process and protocols used by a laboratory for verification of an FDA-approved assay, assess data from the verification studies, and implement the assay after verification. Performance data from the verification studies conducted by the laboratory were consistent with the manufacturer's performance standards and the assay was implemented into the laboratory's test menu. Verification studies are required for FDA-approved diagnostic assays prior to use in patient care. Laboratories should develop a standardized approach to verification studies that can be adapted and applied to different types of assays. We describe the verification of an FDA-approved real-time polymerase chain reaction assay for the detection of a toxin gene in a bacterial pathogen.

  20. Surface enhanced Raman spectroscopy based nanoparticle assays for rapid, point-of-care diagnostics

    NASA Astrophysics Data System (ADS)

    Driscoll, Ashley J.

    Nucleotide and immunoassays are important tools for disease diagnostics. Many of the current laboratory-based analytical diagnostic techniques require multiple assay steps and long incubation times before results are acquired. In the development of bioassays designed for detecting the emergence and spread of diseases in point-of-care (POC) and remote settings, more rapid and portable analytical methods are necessary. Nanoparticles provide simple and reproducible synthetic methods for the preparation of substrates that can be applied in colloidal assays, providing gains in kinetics due to miniaturization and plasmonic substrates for surface enhanced spectroscopies. Specifically, surface enhanced Raman spectroscopy (SERS) is finding broad application as a signal transduction method in immunological and nucleotide assays due to the production of narrow spectral peaks from the scattering molecules and the potential for simultaneous multiple analyte detection. The application of SERS to a no-wash, magnetic capture assay for the detection of West Nile Virus Envelope and Rift Valley Fever Virus N antigens is described. The platform utilizes colloid based capture of the target antigen in solution, magnetic collection of the immunocomplexes and acquisition of SERS spectra by a handheld Raman spectrometer. The reagents for a core-shell nanoparticle, SERS based assay designed for the capture of target microRNA implicated in acute myocardial infarction are also characterized. Several new, small molecule Raman scatterers are introduced and used to analyze the enhancing properties of the synthesized gold coated-magnetic nanoparticles. Nucleotide and immunoassay platforms have shown improvements in speed and analyte capture through the miniaturization of the capture surface and particle-based capture systems can provide a route to further surface miniaturization. A reaction-diffusion model of the colloidal assay platform is presented to understand the interplay of system

  1. Determination of paralytic shellfish toxins in shellfish by receptor binding assay: collaborative study.

    PubMed

    Van Dolah, Frances M; Fire, Spencer E; Leighfield, Tod A; Mikulski, Christina M; Doucette, Gregory J

    2012-01-01

    A collaborative study was conducted on a microplate format receptor binding assay (RBA) for paralytic e shellfish toxins (PST). The assay quantifies the composite PST toxicity in shellfish samples based on the ability of sample extracts to compete with (3)H saxitoxin (STX) diHCl for binding to voltage-gated sodium channels in a rat brain membrane preparation. Quantification of binding can be carried out using either a microplate or traditional scintillation counter; both end points were included in this study. Nine laboratories from six countries completed the study. One laboratory analyzed the samples using the precolumn oxidation HPLC method (AOAC Method 2005.06) to determine the STX congener composition. Three laboratories performed the mouse bioassay (AOAC Method 959.08). The study focused on the ability of the assay to measure the PST toxicity of samples below, near, or slightly above the regulatory limit of 800 (microg STX diHCl equiv./kg). A total of 21 shellfish homogenates were extracted in 0.1 M HCl, and the extracts were analyzed by RBA in three assays on separate days. Samples included naturally contaminated shellfish samples of different species collected from several geographic regions, which contained varying STX congener profiles due to their exposure to different PST-producing dinoflagellate species or differences in toxin metabolism: blue mussel (Mytilus edulis) from the U.S. east and west coasts, California mussel (Mytilus californianus) from the U.S. west coast, chorito mussel (Mytilus chiliensis) from Chile, green mussel (Perna canaliculus) from New Zealand, Atlantic surf clam (Spisula solidissima) from the U.S. east coast, butter clam (Saxidomus gigantea) from the west coast of the United States, almeja clam (Venus antiqua) from Chile, and Atlantic sea scallop (Plactopecten magellanicus) from the U.S. east coast. All samples were provided as whole animal homogenates, except Atlantic sea scallop and green mussel, from which only the

  2. A European multicientre study on the comparison of HIV-1 viral loads between VERIS HIV-1 Assay and Roche COBAS® TAQMAN® HIV-1 test, Abbott RealTime HIV-1 Assay, and Siemens VERSANT HIV-1 Assay.

    PubMed

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Hofmann, Jörg; Izopet, Jacques; Kühn, Sebastian; Lombardi, Alessandra; Mancon, Alessandro; Marcos, Mª Angeles; Mileto, Davide; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel

    2017-07-01

    Viral load monitoring is essential for patients under treatment for HIV. Beckman Coulter has developed the VERIS HIV-1 Assay for use on the novel, automated DxN VERIS Molecular Diagnostics System. ¥ OBJECTIVES: Evaluation of the clinical performance of the new quantitative VERIS HIV-1 Assay at multiple EU laboratories. Method comparison with the VERIS HIV-1 Assay was performed with 415 specimens at 5 sites tested with COBAS ® AmpliPrep/COBAS ® TaqMan ® HIV-1 Test, v2.0, 169 specimens at 3 sites tested with RealTime HIV-1 Assay, and 202 specimens from 2 sites tested with VERSANT HIV-1 Assay. Patient monitoring sample results from 4 sites were also compared. Bland-Altman analysis showed the average bias between VERIS HIV-1 Assay and COBAS HIV-1 Test, RealTime HIV-1 Assay, and VERSANT HIV-1 Assay to be 0.28, 0.39, and 0.61 log 10 cp/mL, respectively. Bias at low end levels below 1000cp/mL showed predicted bias to be <0.3 log 10 cp/mL for VERIS HIV-1 Assay versus COBAS HIV-1 Test and RealTime HIV-1 Assay, and <0.5 log 10 cp/mL versus VERSANT HIV-1 Assay. Analysis on 174 specimens tested with the 0.175mL volume VERIS HIV-1 Assay and COBAS HIV-1 Test showed average bias of 0.39 log 10 cp/mL. Patient monitoring results using VERIS HIV-1 Assay demonstrated similar viral load trends over time to all comparators. The VERIS HIV-1 Assay for use on the DxN VERIS System demonstrated comparable clinical performance to COBAS ® HIV-1 Test, RealTime HIV-1 Assay, and VERSANT HIV-1 Assay. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Laboratory diagnosis of Chlamydia pneumoniae infections

    PubMed Central

    Peeling, Rosanna W

    1995-01-01

    Chlamydia pneumoniae is an important cause of respiratory illness. There is a need for accurate and rapid laboratory diagnostic methods that will lead to improved patient care, appropriate use of antimicrobial therapy and a better understanding of the epidemiology of this emerging pathogen. Culture is highly specific but is technically demanding, expensive, has a long turnaround time and its sensitivity is highly dependent on transport conditions. Antigen detection tests such as enzyme immunoassay and direct fluorescent antibody assay, and molecular detection methods such as the polymerase chain reaction assay, may provide a rapid diagnosis without the requirement for stringent transport conditions. The results of these tests should be interpreted with caution until more thorough evaluation is available. Serology remains the method of choice. The limitations of different serological methods for the laboratory diagnosis of C pneumoniae are discussed. PMID:22514397

  4. Evaluation of a latex agglutination assay for the identification of Burkholderia pseudomallei and Burkholderia mallei.

    PubMed

    Duval, Brea D; Elrod, Mindy G; Gee, Jay E; Chantratita, Narisara; Tandhavanant, Sarunporn; Limmathurotsakul, Direk; Hoffmaster, Alex R

    2014-06-01

    Cases of melioidosis and glanders are rare in the United States, but the etiologic agents of each disease (Burkholderia pseudomallei and Burkholderia mallei, respectively) are classified as Tier 1 select agents because of concerns about their potential use as bioterrorism agents. A rapid, highly sensitive, and portable assay for clinical laboratories and field use is required. Our laboratory has further evaluated a latex agglutination assay for its ability to identify B. pseudomallei and B. mallei isolates. This assay uses a monoclonal antibody that specifically recognizes the capsular polysaccharide produced by B. pseudomallei and B. mallei, but is absent in closely related Burkholderia species. A total of 110 B. pseudomallei and B. mallei were tested, and 36 closely related Burkholderia species. The latex agglutination assay was positive for 109 of 110 (99.1% sensitivity) B. pseudomallei and B. mallei isolates tested. © The American Society of Tropical Medicine and Hygiene.

  5. A murine monoclonal antibody based enzyme-linked immunosorbent assay for almond (Prunus dulcis L.) detection.

    PubMed

    Su, Mengna; Venkatachalam, Mahesh; Liu, Changqi; Zhang, Ying; Roux, Kenneth H; Sathe, Shridhar K

    2013-11-13

    A sandwich enzyme-linked immunosorbent assay (ELISA) using anti-almond soluble protein rabbit polyclonal antibodies as capture antibodies and murine monoclonal antibody 4C10 as the detection antibodies was developed. The assay is specific and sensitive (3-200 ng almond protein/mL) for almond detection. The standardized assay is accurate (<15% CV) and reproducible (intra- and inter assay variability <15% CV). The assay did not register any cross-reactivity with the tested food matrices, suggesting the assay to be almond amandin specific. The assay could detect the presence of declared almond in the tested matched commercial samples. Further, the assay reliably detected the presence of almonds in the laboratory prepared food samples spiked with almond flour.

  6. Detection of Zaire ebolavirus in swine: Assay development and optimization.

    PubMed

    Pickering, B S; Collignon, B; Smith, G; Marszal, P; Kobinger, G; Weingartl, H M

    2018-02-01

    Ebolaviruses (family Filoviridae, order Mononegavirales) cause often fatal, haemorrhagic fever in primates including humans. Pigs have been identified as a species susceptible to Reston ebolavirus (RESTV) infection, with indicated transmission to humans in the Philippines; however, their role during Ebola outbreaks in Africa needs to be clarified. To perform surveillance studies, detection of ebolavirus requires a prerequisite validation of viral RNA and antibody detection methods in swine samples. These diagnostic tests also need to be suitable for deployment to low-level containment laboratories. In this study, we developed a set of tests for detection of antibodies against Zaire ebolavirus (EBOV) in swine. Recombinant EBOV nucleoprotein was produced using a baculovirus expression system for indirect ELISA development. Evaluation of this assay was performed using laboratory and field samples, achieving a diagnostic specificity of 99%. Importantly, the indirect ELISA was able to detect antibodies to EBOV at 7 dpi, 3 days earlier than virus neutralization tests (VNT). The format of the VNT in this work was modified to a microtitre plaque reduction neutralization assay (miPRNT) complemented with immunostaining to provide a more rapid and highly specific assay. Finally, a confirmatory immunoblot assay was generated to supplement the indirect ELISA results. © 2017 Her Majesty the Queen in Right of Canada Reproduced with the permission of the Minister of Health and Agriculture, Canadian Food Inspection Agency.

  7. Comparison of the Chiron Quantiplex branched DNA (bDNA) assay and the Abbott Genostics solution hybridization assay for quantification of hepatitis B viral DNA.

    PubMed

    Kapke, G E; Watson, G; Sheffler, S; Hunt, D; Frederick, C

    1997-01-01

    Several assays for quantification of DNA have been developed and are currently used in research and clinical laboratories. However, comparison of assay results has been difficult owing to the use of different standards and units of measurements as well as differences between assays in dynamic range and quantification limits. Although a few studies have compared results generated by different assays, there has been no consensus on conversion factors and thorough analysis has been precluded by small sample size and limited dynamic range studied. In this study, we have compared the Chiron branched DNA (bDNA) and Abbott liquid hybridization assays for quantification of hepatitis B virus (HBV) DNA in clinical specimens and have derived conversion factors to facilitate comparison of assay results. Additivity and variance stabilizing (AVAS) regression, a form of non-linear regression analysis, was performed on assay results for specimens from HBV clinical trials. Our results show that there is a strong linear relationship (R2 = 0.96) between log Chiron and log Abbott assay results. Conversion factors derived from regression analyses were found to be non-constant and ranged from 6-40. Analysis of paired assay results below and above each assay's limit of quantification (LOQ) indicated that a significantly (P < 0.01) larger proportion of observations were below the Abbott assay LOQ but above the Chiron assay LOQ, indicating that the Chiron assay is significantly more sensitive than the Abbott assay. Testing of replicate specimens showed that the Chiron assay consistently yielded lower per cent coefficients of variance (% CVs) than the Abbott assay, indicating that the Chiron assay provides superior precision.

  8. BIOMARKER ASSAYS IN NIPPLE APIRATE FLUID

    EPA Science Inventory

    ABSTRACT

    The noninvasive technique of nipple aspiration as a potential source of biomarkers of breast cancer risk was evaluated. The feasibility of performing mutagenesis assays, amplifying DNA and performing protein electrophoresis on nipple aspirate fluid was explored. ...

  9. Multi-Laboratory Study of Five Methods for the Determination of Brevetoxins in Shellfish Tissue Extracts.

    PubMed

    Dickey, Robert W; Plakas, Steven M; Jester, Edward L E; El Said, Kathleen R; Johannessen, Jan N; Flewelling, Leanne J; Scott, Paula; Hammond, Dan G; Van Dolah, Frances M; Leighfield, Tod A; Bottein Dachraoui, Marie-Yasmine; Ramsdell, John S; Pierce, Richard H; Henry, Mike S; Poli, Mark A; Walker, Calvin; Kurtz, Jan; Naar, Jerome; Baden, Daniel G; Musser, Steve M; White, Kevin D; Truman, Penelope; Miller, Aaron; Hawryluk, Timothy P; Wekell, Marleen M; Stirling, David; Quilliam, Michael A; Lee, Jung K

    A thirteen-laboratory comparative study tested the performance of four methods as alternatives to mouse bioassay for the determination of brevetoxins in shellfish. The methods were N2a neuroblastoma cell assay, two variations of the sodium channel receptor binding assay, competitive ELISA, and LC/MS. Three to five laboratories independently performed each method using centrally prepared spiked and naturally incurred test samples. Competitive ELISA and receptor binding (96-well format) compared most favorably with mouse bioassay. Between-laboratory relative standard deviations (RSDR) ranged from 10 to 20% for ELISA and 14 to 31% for receptor binding. Within-laboratory (RSDr) ranged from 6 to 15% for ELISA, and 5 to 31% for receptor binding. Cell assay was extremely sensitive but data variation rendered it unsuitable for statistical treatment. LC/MS performed as well as ELISA on spiked test samples but was inordinately affected by lack of toxin-metabolite standards, uniform instrumental parameters, or both, on incurred test samples. The ELISA and receptor binding assay are good alternatives to mouse bioassay for the determination of brevetoxins in shellfish.

  10. Evaluation of the Abbott RealTime HCV assay for quantitative detection of hepatitis C virus RNA.

    PubMed

    Michelin, Birgit D A; Muller, Zsofia; Stelzl, Evelyn; Marth, Egon; Kessler, Harald H

    2007-02-01

    The Abbott RealTime HCV assay for quantitative detection of HCV RNA has recently been introduced. In this study, the performance of the Abbott RealTime HCV assay was evaluated and compared to the COBAS AmpliPrep/COBAS TaqMan HCV test. Accuracy, linearity, interassay and intra-assay variations were determined, and a total of 243 routine clinical samples were investigated. When accuracy of the new assay was tested, the majority of results were found to be within +/-0.5 log(10) unit of the results obtained by reference laboratories. Determination of linearity resulted in a quasilinear curve up to 1.0 x 10(6)IU/ml. The interassay variation ranged from 15% to 32%, and the intra-assay variation ranged from 5% to 8%. When clinical samples were tested by the Abbott RealTime HCV assay and the results were compared with those obtained by the COBAS AmpliPrep/COBAS TaqMan HCV test, the results for 93% of all samples with positive results by both tests were found to be within +/-1.0 log(10) unit. The viral loads for all patients measured by the Abbott and Roche assays showed a high correlation (R(2)=0.93); quantitative results obtained by the Abbott assay were found to be lower than those obtained by the Roche assay. The Abbott RealTime HCV assay proved to be suitable for use in the routine diagnostic laboratory. The time to results was similar for both of the assays.

  11. Drosophila comet assay: insights, uses, and future perspectives

    PubMed Central

    Gaivão, Isabel; Sierra, L. María

    2014-01-01

    The comet assay, a very useful tool in genotoxicity and DNA repair testing, is being applied to Drosophila melanogaster since around 15 years ago, by several research groups. This organism is a valuable model for all kind of processes related to human health, including DNA damage response. The assay has been performed mainly in vivo using different larvae cell types (from brain, midgut, hemolymph, and imaginal disk), but also in vitro with the S2 cell line. Since its first application, it has been used to analyze the genotoxicity and action mechanisms of different chemicals, demonstrating good sensitivity and proving its usefulness. Moreover, it is the only assay that can be used to analyze DNA repair in somatic cells in vivo, comparing the effects of chemicals in different repair strains, and to quantitate repair activities in vitro. Additionally, the comet assay in Drosophila, in vivo and in vitro, has been applied to study the influence of protein overexpression on genome integrity and degradation. Although the assay is well established, it could benefit from some research to determine optimal experimental design to standardize it, and then to allow comparisons among laboratories independently of the chosen cell type. PMID:25221574

  12. USING THE LANGUAGE LABORATORY.

    ERIC Educational Resources Information Center

    LADU, TORA TUVE

    TO ENCOURAGE UTILIZATION OF THE LANGUAGE LABORATORY AS A TEACHING TECHNIQUE, THIS BULLETIN DESCRIBES SUCH POSSIBLE USES OF THE LABORATORY AS PROGRAMING LESSONS, RECORDING, AND TESTING LANGUAGE SKILL DEVELOPMENT. ONE OF THE MOST IMPORTANT FUNCTIONS OF THE LABORATORY IS THE PATTERN DRILL, DESCRIBED HERE FOR FRENCH, GERMAN, AND SPANISH. EXAMPLES ARE…

  13. Near surface geophysical techniques on subsoil contamination: laboratory experiments

    NASA Astrophysics Data System (ADS)

    Capozzoli, Luigi; Giampaolo, Valeria; Rizzo, Enzo

    2016-04-01

    Hydrocarbons contamination of soil and groundwater has become a serious environmental problem, because of the increasing number of accidental spills caused by human activities. The starting point of any studies is the reconstruction of the conceptual site model. To make valid predictions about the flow pathways following by hydrocarbons compound is necessary to make a correct reconstruction of their characteristics and the environment in which they move. Near-surface geophysical methods, based on the study of electrical and electromagnetic properties, are proved to be very useful in mapping spatial distribution of the organic contaminants in the subsurface. It is well known, in fact, that electrical properties of the porous media are significantly influenced by hydrocarbons because, when contaminants enter the rock matrix, surface reaction occur between the contaminant and the soil grain surface. The main aim of this work is to investigate the capability of near-surface geophysical methods in mapping and monitoring spatial distribution of contaminants in a controlled setting. A laboratory experiment has been performed at the Hydrogeosite Laboratory of CNR-IMAA (Marsico Nuovo, PZ) where a box-sand has been contaminated by diesel. The used contaminant is a LNAPL, added to the sand through a drilled pipe. Contaminant behaviour and its migration paths have been monitored for one year by Electrical Resistivity measurements. In details, a Cross Borehole Electrical Resistivity Tomography techniques were used to characterize the contamination dynamics after a controlled hydrocarbon spillage occurring in the vadose zone. The approach with cross-borehole resistivity imaging provide a great advantage compared to more conventional surface electrical resistivity tomography, due to the high resolution at high depth (obviously depending on the depth of the well instrumented for the acquisition). This method has been shown to provide good information on the distribution of

  14. Use of the Genomic Subtractive Hybridization Technique To Develop a Real-Time PCR Assay for Quantitative Detection of Prevotella spp. in Oral Biofilm Samples

    PubMed Central

    Nagashima, Shiori; Yoshida, Akihiro; Suzuki, Nao; Ansai, Toshihiro; Takehara, Tadamichi

    2005-01-01

    Genomic subtractive hybridization was used to design Prevotella nigrescens-specific primers and TaqMan probes. Based on this technique, a TaqMan real-time PCR assay was developed for quantifying four oral black-pigmented Prevotella species. The combination of real-time PCR and genomic subtractive hybridization is useful for preparing species-specific primer-probe sets for closely related species. PMID:15956428

  15. Integrated Summary Report: Validation of Two Binding Assays Using Human Recombinant Estrogen Receptor Alpha (hrERa)

    EPA Science Inventory

    This Integrated Summary Report (ISR) summarizes, in a single document, the results from an international multi-laboratory validation study conducted for two in vitro estrogen receptor (ER) binding assays. These assays both use human recombinant estrogen receptor, alpha subtype (h...

  16. Recombinase polymerase amplification assay for rapid detection of lumpy skin disease virus.

    PubMed

    Shalaby, Mohamed A; El-Deeb, Ayman; El-Tholoth, Mohamed; Hoffmann, Donata; Czerny, Claus-Peter; Hufert, Frank T; Weidmann, Manfred; Abd El Wahed, Ahmed

    2016-11-02

    Lumpy skin disease virus (LSDV) is a Capripoxvirus infecting cattle and Buffalos. Lumpy skin disease (LSD) leads to significant economic losses due to hide damage, reduction of milk production, mastitis, infertility and mortalities (10 %). Early detection of the virus is crucial to start appropriate outbreak control measures. Veterinarians rely on the presence of the characteristic clinical signs of LSD. Laboratory diagnostics including virus isolation, sequencing and real-time polymerase chain reaction (PCR) are performed at well-equipped laboratories. In this study, a portable, simple, and rapid recombinase polymerase amplification (RPA) assay for the detection of LSDV-genome for the use on farms was developed. The LSDV RPA assay was performed at 42 °C and detected down to 179 DNA copies/reaction in a maximum of 15 min. Unspecific amplification was observed with neither LSDV-negative samples (n = 12) nor nucleic acid preparations from orf virus, bovine papular stomatitis virus, cowpoxvirus, Peste des petits ruminants and Blue tongue virus (serotypes 1, 6 and 8). The clinical sensitivity of the LSDV RPA assay matched 100 % (n = 22) to real-time PCR results. In addition, the LSDV RPA assay detected sheep and goat poxviruses. The LSDV RPA assay is a rapid and sensitive test that could be implemented in field or at quarantine stations for the identification of LSDV infected case.

  17. Evaluation of the VIDAS Anti-HCV Assay for Detection of Hepatitis C Virus Infection.

    PubMed

    Hyun, Jungwon; Ko, Dae Hyun; Kang, Hee Jung; Whang, Dong Hee; Cha, Young Joo; Kim, Hyun Soo

    2016-11-01

    Anti-hepatitis C virus antibody (anti-HCV) assays are recommended for screening HCV-infected persons. The VIDAS Anti-HCV Assay (bioMérieux, France), based on the enzyme-linked fluorescence test principle, was recently introduced in Korea. We evaluated the clinical performance of the VIDAS assay. One hundred HCV-positive and 1,002 HCV-negative blood samples confirmed by Architect anti-HCV (Abbott Laboratories, USA) and COBAS TaqMan HCV real-time PCR (Roche Diagnostics, USA) or the Procleix Ultrio Plus Assay (Gen-Probe Incorporated, USA) were obtained from the Human Serum Bank (HSB) and tested by VIDAS. In case of discrepant results, we conducted a recombinant immunoblot assay (RIBA). The agreement rates for known HCV-positive and HCV-negative samples between the VIDAS assay and the HSB testing were 100% (95% confidence interval [CI]: 96.4-100%) and 99.5% (95% CI: 98.8-99.8%), respectively. One of the five discrepant samples was positive for Core 2+ and NS3-2 2+ reactivity, two samples were negative, and the other two were indeterminate regarding NS4 2+ reactivity in RIBA. We observed a significant but weak positive correlation between the titers of VIDAS and Architect assays (r=0.315, P<0.001). The VIDAS anti-HCV assay, developed on the VIDAS automated immunoassay platform based on the ready-to-use, single-sample test concept may be useful in small-to-medium-sized laboratories. It showed good agreement with Architect anti-HCV and COBAS PCR assays and is therefore useful for detection of HCV infection. Weakly test-positive (ambiguous) samples require additional testing by another anti-HCV, RIBA, or HCV RNA assay.

  18. Evaluation of the VIDAS Anti-HCV Assay for Detection of Hepatitis C Virus Infection

    PubMed Central

    Hyun, Jungwon; Ko, Dae-Hyun; Kang, Hee Jung; Whang, Dong Hee

    2016-01-01

    Background Anti-hepatitis C virus antibody (anti-HCV) assays are recommended for screening HCV-infected persons. The VIDAS Anti-HCV Assay (bioMérieux, France), based on the enzyme-linked fluorescence test principle, was recently introduced in Korea. We evaluated the clinical performance of the VIDAS assay. Methods One hundred HCV-positive and 1,002 HCV-negative blood samples confirmed by Architect anti-HCV (Abbott Laboratories, USA) and COBAS TaqMan HCV real-time PCR (Roche Diagnostics, USA) or the Procleix Ultrio Plus Assay (Gen-Probe Incorporated, USA) were obtained from the Human Serum Bank (HSB) and tested by VIDAS. In case of discrepant results, we conducted a recombinant immunoblot assay (RIBA). Results The agreement rates for known HCV-positive and HCV-negative samples between the VIDAS assay and the HSB testing were 100% (95% confidence interval [CI]: 96.4-100%) and 99.5% (95% CI: 98.8-99.8%), respectively. One of the five discrepant samples was positive for Core 2+ and NS3-2 2+ reactivity, two samples were negative, and the other two were indeterminate regarding NS4 2+ reactivity in RIBA. We observed a significant but weak positive correlation between the titers of VIDAS and Architect assays (r=0.315, P<0.001). Conclusions The VIDAS anti-HCV assay, developed on the VIDAS automated immunoassay platform based on the ready-to-use, single-sample test concept may be useful in small-to-medium-sized laboratories. It showed good agreement with Architect anti-HCV and COBAS PCR assays and is therefore useful for detection of HCV infection. Weakly test-positive (ambiguous) samples require additional testing by another anti-HCV, RIBA, or HCV RNA assay. PMID:27578508

  19. Assay for Arf GTP-binding Proteins | NCI Technology Transfer Center | TTC

    Cancer.gov

    The National Cancer Institute's Laboratory of Cellular and Molecular Biology is seeking statements of capability or interest from parties interested in collaborative research to further develop, evaluate, or commercialize an antibody-based proteomics assay.

  20. Evaluation of Toxoplasma ELITe MGB Real-Time PCR Assay for Diagnosis of Toxoplasmosis

    PubMed Central

    Brenier-Pinchart, Marie-Pierre; Yera, Hélène; Belaz, Sorya; Varlet-Marie, Emmanuelle; Bastien, Patrick

    2017-01-01

    ABSTRACT Molecular diagnosis of congenital toxoplasmosis or disseminated toxoplasmosis is based mainly on PCR. The repeated DNA element rep529 has become the main DNA target used in most PCR methods, whether laboratory developed or commercial. In this multicenter study, we evaluated the Toxoplasma ELITe MGB (Elitech) commercial kit by comparison with three reference quantitative PCR assays (RAs) used routinely in three proficient laboratories of the French National Reference Center for Toxoplasmosis network, using Toxoplasma calibrated suspensions diluted to obtain a range of concentrations from 0.1 to 10,000 parasites/ml. These suspensions were extracted with either the DNA extraction kit (EXTRAblood; Elitech) recommended by the manufacturer or the QIAamp DNA minikit (Qiagen). The Toxoplasma ELITe MGB assay was also evaluated on a panel of 128 clinical samples, including 56 amniotic fluid samples, 55 placenta samples, and various other samples, of which 95 originated from patients with proven toxoplasmosis. The ELITe MGB assay amplified low-concentration replicates (<10 parasites/ml) of calibrated suspensions less frequently than the RAs of 2/3 laboratories. Additionally, the combination of EXTRAblood and Toxoplasma ELITe MGB yielded poorer sensitivity than the combination of QIAamp DNA minikit and ELITe MGB for low parasite concentrations (P < 0.001 for 1 parasite/ml). On clinical samples, the sensitivity and the specificity of the commercial assay were 89% and 100%, respectively. The sensitivity ranged from 79% (placenta samples) to 100% (amniotic fluid samples). Overall, this study shows that the Toxoplasma ELITe MGB assay is suitable for the diagnosis of toxoplasmosis from non-cell-rich or non-hemoglobin-rich samples and that the EXTRAblood kit is not optimal. PMID:28202794

  1. Evaluation of Toxoplasma ELITe MGB Real-Time PCR Assay for Diagnosis of Toxoplasmosis.

    PubMed

    Robert-Gangneux, Florence; Brenier-Pinchart, Marie-Pierre; Yera, Hélène; Belaz, Sorya; Varlet-Marie, Emmanuelle; Bastien, Patrick

    2017-05-01

    Molecular diagnosis of congenital toxoplasmosis or disseminated toxoplasmosis is based mainly on PCR. The repeated DNA element rep529 has become the main DNA target used in most PCR methods, whether laboratory developed or commercial. In this multicenter study, we evaluated the Toxoplasma ELITe MGB (Elitech) commercial kit by comparison with three reference quantitative PCR assays (RAs) used routinely in three proficient laboratories of the French National Reference Center for Toxoplasmosis network, using Toxoplasma calibrated suspensions diluted to obtain a range of concentrations from 0.1 to 10,000 parasites/ml. These suspensions were extracted with either the DNA extraction kit (EXTRAblood; Elitech) recommended by the manufacturer or the QIAamp DNA minikit (Qiagen). The Toxoplasma ELITe MGB assay was also evaluated on a panel of 128 clinical samples, including 56 amniotic fluid samples, 55 placenta samples, and various other samples, of which 95 originated from patients with proven toxoplasmosis. The ELITe MGB assay amplified low-concentration replicates (<10 parasites/ml) of calibrated suspensions less frequently than the RAs of 2/3 laboratories. Additionally, the combination of EXTRAblood and Toxoplasma ELITe MGB yielded poorer sensitivity than the combination of QIAamp DNA minikit and ELITe MGB for low parasite concentrations ( P < 0.001 for 1 parasite/ml). On clinical samples, the sensitivity and the specificity of the commercial assay were 89% and 100%, respectively. The sensitivity ranged from 79% (placenta samples) to 100% (amniotic fluid samples). Overall, this study shows that the Toxoplasma ELITe MGB assay is suitable for the diagnosis of toxoplasmosis from non-cell-rich or non-hemoglobin-rich samples and that the EXTRAblood kit is not optimal. Copyright © 2017 American Society for Microbiology.

  2. Fischer Assays of Oil-Shale Drill Cores and Rotary Cuttings from the Greater Green River Basin, Southwestern Wyoming

    USGS Publications Warehouse

    ,

    2008-01-01

    Chapter 1 of this CD-ROM is a database of digitized Fischer (shale-oil) assays of cores and cuttings from boreholes drilled in the Eocene Green River oil shale deposits in southwestern Wyoming. Assays of samples from some surface sections are also included. Most of the Fischer assay analyses were made by the former U.S. Bureau of Mines (USBM) at its laboratory in Laramie, Wyoming. Other assays, made by institutional or private laboratories, were donated to the U.S. Geological Survey (USGS) and are included in this database as well as Adobe PDF-scanned images of some of the original laboratory assay reports and lithologic logs prepared by USBM geologists. The size of this database is 75.2 megabytes and includes information on 971 core holes and rotary-drilled boreholes and numerous surface sections. Most of these data were released previously by the USBM and the USGS through the National Technical Information Service but are no longer available from that agency. Fischer assays for boreholes in northeastern Utah and northwestern Colorado have been published by the USGS. Additional data include geophysical logs, groundwater data, chemical and X-ray diffraction analyses, and other data. These materials are available for inspection in the office of the USGS Central Energy Resources Team in Lakewood, Colorado. The digitized assays were checked with the original laboratory reports, but some errors likely remain. Other information, such as locations and elevations of core holes and oil and gas tests, were not thoroughly checked. However, owing to the current interest in oil-shale development, it was considered in the public interest to make this preliminary database available at this time. Chapter 2 of this CD-ROM presents oil-yield histograms of samples of cores and cuttings from exploration drill holes in the Eocene Green River Formation in the Great Divide, Green River, and Washakie Basins of southwestern Wyoming. A database was compiled that includes about 47

  3. Video Teleconferencing in the Compounding Laboratory Component of a Dual-Campus Doctor of Pharmacy Program

    PubMed Central

    Shrewsbury, Robert P.

    2011-01-01

    Objectives. To design, implement, and assess the effectiveness of using a live video teleconferencing system to connect the main campus and a satellite campus during laboratory compounding exercises in a doctor of pharmacy (PharmD) program. Design. A new laboratory facility with identical equipment and supplies to the main campus was built at the satellite campus and teleconferencing equipment was set up. Students on both campuses prepared 20 compounded formulations over a 5-course pharmaceutical care laboratory sequence. Live video teleconferencing was used for students to ask questions and for the lead faculty instructor to observe the students’ technique. Faculty and staff members and teaching assistants facilitated the laboratory sessions on both campuses. Assessment. The performance of students on assayed products at the main campus was compared with that of students at the satellite campus to ensure program integrity with the compounding laboratory component. The use of video teleconferencing for teaching compounding was successful and no difference in overall student pass rates was seen. The few observed differences in student performance between the 2 campuses were believed to be a result of variations in instructor communication with distant students. Conclusion. Video teleconferencing can be used successfully to deliver curriculum in laboratory compounding to pharmacy students. PMID:22171109

  4. Phenotypic Drug Susceptibility Assay for Influenza Virus Neuraminidase Inhibitors

    PubMed Central

    McSharry, James J.; McDonough, Ann C.; Olson, Betty A.; Drusano, George L.

    2004-01-01

    A flow cytometric (fluorescence-activated cell sorter [FACS]) assay was developed for analysis of the drug susceptibilities of wild-type and drug-resistant influenza A and B virus laboratory strains and clinical isolates for the neuraminidase (NA) inhibitors oseltamivir carboxylate, zanamivir, and peramivir. The drug susceptibilities of wild-type influenza viruses and those with mutations in the hemagglutinin (HA) and/or NA genes rendering them resistant to one or more of the NA inhibitors were easily determined with the FACS assay. The drug concentrations that reduced the number of virus-infected cells or the number of PFU by 50% as determined by the FACS assay were similar to those obtained with the more time-consuming and labor-intensive virus yield reduction assay. The NA inhibition (NAI) assay confirmed the resistance patterns demonstrated by the FACS and virus yield assays for drug-resistant influenza viruses with mutations in the NA gene. However, only the FACS and virus yield assays detected NA inhibitor-resistant influenza viruses with mutations in the HA gene but not in the NA gene. The FACS assay is more rapid and less labor-intensive than the virus yield assay and just as quantitative. The FACS assay determines the drug susceptibilities of influenza viruses with mutations in either the HA or NA genes, making the assay more broadly useful than the NAI assay for measuring the in vitro susceptibilities of influenza viruses for NA inhibitors. However, since only viruses with mutations in the NA gene that lead to resistance to the NA inhibitors correlate with clinical resistance, this in vitro assay should not be used in the clinical setting to determine resistance to NA inhibitors. The assay may be useful for determining the in vivo susceptibilities of other compounds effective against influenza A and B viruses. PMID:14715540

  5. Multicenter comparison of levels of antibody to the Neisseria meningitidis group A capsular polysaccharide measured by using an enzyme-linked immunosorbent assay.

    PubMed Central

    Carlone, G M; Frasch, C E; Siber, G R; Quataert, S; Gheesling, L L; Turner, S H; Plikaytis, B D; Helsel, L O; DeWitt, W E; Bibb, W F

    1992-01-01

    There is no standard immunoassay for evaluating immune responses to meningococcal vaccines. We developed an enzyme-linked immunosorbent assay to measure total levels of antibody to Neisseria meningitidis group A capsular polysaccharide. Five laboratories measured the antibody levels in six paired pre- and postvaccination serum samples by using the enzyme-linked immunosorbent assay. Methylated human serum albumin was used to bind native group A polysaccharide to microtiter plate surfaces. The between-laboratory coefficients of variation for pre- and postvaccination sera had ranges of 31 to 91 and 17 to 31, respectively. The mean laboratory coefficients of variation for pre- and postvaccination sera, respectively, were 17 and 11 (Molecular Biology Laboratory, Centers for Disease Control), 12 and 15 (Immunodiagnostic Methods Laboratory, Centers for Disease Control), 22 and 19 (Dana-Farber Cancer Institute), 38 and 38 (Bacterial Polysaccharide Laboratory, U.S. Food and Drug Administration), and 11 and 10 (Praxis Biologics, Inc.). Standardization of this enzyme-linked immunosorbent assay should allow interlaboratory comparison of meningococcal vaccine immunogenicity, thus providing a laboratory-based assessment tool for evaluating meningococcal vaccines. PMID:1734048

  6. Loop-Mediated Isothermal Amplification for Laboratory Confirmation of Buruli Ulcer Disease—Towards a Point-of-Care Test

    PubMed Central

    Beissner, Marcus; Phillips, Richard Odame; Battke, Florian; Bauer, Malkin; Badziklou, Kossi; Sarfo, Fred Stephen; Maman, Issaka; Rhomberg, Agata; Piten, Ebekalisai; Frimpong, Michael; Huber, Kristina Lydia; Symank, Dominik; Jansson, Moritz; Wiedemann, Franz Xaver; Banla Kere, Abiba; Herbinger, Karl-Heinz; Löscher, Thomas; Bretzel, Gisela

    2015-01-01

    Background As the major burden of Buruli ulcer disease (BUD) occurs in remote rural areas, development of point-of-care (POC) tests is considered a research priority to bring diagnostic services closer to the patients. Loop-mediated isothermal amplification (LAMP), a simple, robust and cost-effective technology, has been selected as a promising POC test candidate. Three BUD-specific LAMP assays are available to date, but various technical challenges still hamper decentralized application. To overcome the requirement of cold-chains for transport and storage of reagents, the aim of this study was to establish a dry-reagent-based LAMP assay (DRB-LAMP) employing lyophilized reagents. Methodology/Principal Findings Following the design of an IS2404 based conventional LAMP (cLAMP) assay suitable to apply lyophilized reagents, a lyophylization protocol for the DRB-LAMP format was developed. Clinical performance of cLAMP was validated through testing of 140 clinical samples from 91 suspected BUD cases by routine assays, i.e. IS2404 dry-reagent-based (DRB) PCR, conventional IS2404 PCR (cPCR), IS2404 qPCR, compared to cLAMP. Whereas qPCR rendered an additional 10% of confirmed cases and samples respectively, case confirmation and positivity rates of DRB-PCR or cPCR (64.84% and 56.43%; 100% concordant results in both assays) and cLAMP (62.64% and 52.86%) were comparable and there was no significant difference between the sensitivity of the assays (DRB PCR and cPCR, 86.76%; cLAMP, 83.82%). Likewise, sensitivity of cLAMP (95.83%) and DRB-LAMP (91.67%) were comparable as determined on a set of 24 samples tested positive in all routine assays. Conclusions/Significance Both LAMP formats constitute equivalent alternatives to conventional PCR techniques. Provided the envisaged availability of field friendly DNA extraction formats, both assays are suitable for decentralized laboratory confirmation of BUD, whereby DRB-LAMP scores with the additional advantage of not requiring cold

  7. Role of congenital rubella reference laboratory: 21-months-surveillance in Liguria, Italy.

    PubMed

    Canepa, P; Valle, L; Cristina, E; De Florentiis, D; Parodi, V; Banfi, F; Zancolli, M; Durando, P; Icardi, G; Ansaldi, F

    2009-12-01

    Rubella is generally a mild rush fever disease when acquired in childhood, but when infection occurs during the first months of pregnancy, high risk of trans-placental transmission to the foetus and of congenital anomalies exists. In November 2003, a National Plan for measles and congenital rubella elimination was approved in Italy. The aim was to reduce and maintain Congenital Rubella Syndrome incidence lower than 1 case per 100,000 live births/year by 2007. Since June 2006, Liguria Administrative Region recognized U.O. Hygiene, "San Martino" University Hospital, Genoa, as regional reference laboratory for diagnosis of rubella infection during pregnancy and post-partum. Twenty-one-month virological-surveillance results between April 2007 and December 2008 were reported in terms of demographic data, risk factors, access reasons, clinical picture, vaccination, previous rubella disease, laboratory results of pregnant women and newborns. Since the beginning of surveillance, 65 pregnant women with suspected virus infection and 18 newborns with suspected congenital rubella were followed up. The results of laboratory surveillance highlighted (i) the importance of an early screening, (ii) the suboptimal specificity of chemiluminescent assays, that often yield false positive IgM results and (iii) the fundamental role of second-level laboratory to confirm the serological diagnosis and to detect the virus by molecular techniques.

  8. Rapid and simple detection of foot-and-mouth disease virus: Evaluation of a cartridge-based molecular detection system for use in basic laboratories.

    PubMed

    Goller, K V; Dill, V; Madi, M; Martin, P; Van der Stede, Y; Vandenberge, V; Haas, B; Van Borm, S; Koenen, F; Kasanga, C J; Ndusilo, N; Beer, M; Liu, L; Mioulet, V; Armson, B; King, D P; Fowler, V L

    2018-04-01

    Highly contagious transboundary animal diseases such as foot-and-mouth disease (FMD) are major threats to the productivity of farm animals. To limit the impact of outbreaks and to take efficient steps towards a timely control and eradication of the disease, rapid and reliable diagnostic systems are of utmost importance. Confirmatory diagnostic assays are typically performed by experienced operators in specialized laboratories, and access to this capability is often limited in the developing countries with the highest disease burden. Advances in molecular technologies allow implementation of modern and reliable techniques for quick and simple pathogen detection either in basic laboratories or even at the pen-side. Here, we report on a study to evaluate a fully automated cartridge-based real-time RT-PCR diagnostic system (Enigma MiniLab ® ) for the detection of FMD virus (FMDV). The modular system integrates both nucleic acid extraction and downstream real-time RT-PCR (rRT-PCR). The analytical sensitivity of this assay was determined using serially diluted culture grown FMDV, and the performance of the assay was evaluated using a selected range of FMDV positive and negative clinical samples of bovine, porcine and ovine origin. The robustness of the assay was evaluated in an international inter-laboratory proficiency test and by deployment into an African laboratory. It was demonstrated that the system is easy to use and can detect FMDV with high sensitivity and specificity, roughly on par with standard laboratory methods. This cartridge-based automated real-time RT-PCR system for the detection of FMDV represents a reliable and easy to use diagnostic tool for the early and rapid disease detection of acutely infected animals even in remote areas. This type of system could be easily deployed for routine surveillance within endemic regions such as Africa or could alternatively be used in the developed world. © 2017 The Authors. Transboundary and Emerging Diseases

  9. Physics Laboratory Investigation of Vocational High School Field Stone and Concrete Construction Techniques in the Central Java Province (Indonesia)

    ERIC Educational Resources Information Center

    Purwandari, Ristiana Dyah

    2015-01-01

    The investigation aims in this study were to uncover the observations of infrastructures and physics laboratory in vocational high school for Stone and Concrete Construction Techniques Expertise Field or Teknik Konstruksi Batu dan Beton (TKBB)'s in Purwokerto Central Java Province, mapping the Vocational High School or Sekolah Menengah Kejuruan…

  10. Enumeration of major peripheral blood leukocyte populations for multicenter clinical trials using a whole blood phenotyping assay.

    PubMed

    Hensley, Tiffany R; Easter, Austin B; Gerdts, Sarah E; De Rosa, Stephen C; Heit, Antje; McElrath, M Juliana; Andersen-Nissen, Erica

    2012-09-16

    Cryopreservation of peripheral blood leukocytes is widely used to preserve cells for immune response evaluations in clinical trials and offers many advantages for ease and standardization of immunological assessments, but detrimental effects of this process have been observed on some cell subsets, such as granulocytes, B cells, and dendritic cells. Assaying fresh leukocytes gives a more accurate picture of the in vivo state of the cells, but is often difficult to perform in the context of large clinical trials. Fresh cell assays are dependent upon volunteer commitments and timeframes and, if time-consuming, their application can be impractical due to the working hours required of laboratory personnel. In addition, when trials are conducted at multiple centers, laboratories with the resources and training necessary to perform the assays may not be located in sufficient proximity to clinical sites. To address these issues, we have developed an 11-color antibody staining panel that can be used with Trucount tubes (Becton Dickinson; San Jose, CA) to phenotype and enumerate the major leukocyte populations within the peripheral blood, yielding more robust cell-type specific information than assays such as a complete blood count (CBC) or assays with commercially-available panels designed for Trucount tubes that stain for only a few cell types. The staining procedure is simple, requires only 100 μl of fresh whole blood, and takes approximately 45 minutes, making it feasible for standard blood-processing labs to perform. It is adapted from the BD Trucount tube technical data sheet (version 8/2010). The staining antibody cocktail can be prepared in advance in bulk at a central assay laboratory and shipped to the site processing labs. Stained tubes can be fixed and frozen for shipment to the central assay laboratory for multicolor flow cytometry analysis. The data generated from this staining panel can be used to track changes in leukocyte concentrations over time in

  11. Real-time polymerase chain reaction assay for rapid and sensitive detection of anthrax spores in spiked soil and talcum powder.

    PubMed

    Jain, Neha; Merwyn, S; Rai, G P; Agarwal, G S

    2012-05-01

    Real-time polymerase chain reaction (real-time PCR) is a laboratory technique based on PCR. This technique is able to detect sequence-specific PCR products as they accumulate in "real time" during the PCR amplification, and also to quantify the number of substrates present in the initial PCR mixture before amplification begins. In the present study, real-time PCR assay was employed for rapid and real-time detection of Bacillus anthracis spores spiked in 0.1 g of soil and talcum powder ranging from 5 to 10(7) spores. DNA was isolated from spiked soil and talcum powder, using PBS containing 1 % Triton-X-100, followed by heat treatment. The isolated DNA was used as template for real-time PCR and PCR. Real-time PCR amplification was obtained in 60 min under the annealing condition at 60°C by employing primers targeting the pag gene of B. anthracis. In the present study, the detection limit of real-time PCR assay in soil was 10(3) spores and 10(2) spores in talcum powder, respectively, whereas PCR could detect 10(4) spores in soil and 10(3) spores in talcum powder, respectively.

  12. Validity of urinary monoamine assay sales under the “spot baseline urinary neurotransmitter testing marketing model”

    PubMed Central

    Hinz, Marty; Stein, Alvin; Uncini, Thomas

    2011-01-01

    Spot baseline urinary monoamine assays have been used in medicine for over 50 years as a screening test for monoamine-secreting tumors, such as pheochromocytoma and carcinoid syndrome. In these disease states, when the result of a spot baseline monoamine assay is above the specific value set by the laboratory, it is an indication to obtain a 24-hour urine sample to make a definitive diagnosis. There are no defined applications where spot baseline urinary monoamine assays can be used to diagnose disease or other states directly. No peer-reviewed published original research exists which demonstrates that these assays are valid in the treatment of individual patients in the clinical setting. Since 2001, urinary monoamine assay sales have been promoted for numerous applications under the “spot baseline urinary neurotransmitter testing marketing model”. There is no published peer-reviewed original research that defines the scientific foundation upon which the claims for these assays are made. On the contrary, several articles have been published that discredit various aspects of the model. To fill the void, this manuscript is a comprehensive review of the scientific foundation and claims put forth by laboratories selling urinary monoamine assays under the spot baseline urinary neurotransmitter testing marketing model. PMID:21912487

  13. Key Learnings from the Endocrine Disruptor Screening Program (EDSP) Tier 1 Rodent Uterotrophic and Hershberger Assays

    PubMed Central

    Marty, M Sue; O'Connor, John C

    2014-01-01

    In 2009, companies began screening compounds using the US Environmental Protection Agency's Endocrine Disruptor Screening Program (EDSP). EDSP has two tiers: Tier 1 includes 11 assays to identify compounds with potential endocrine activity. This article describes two laboratories' experiences conducting Tier 1 uterotrophic and Hershberger assays. The uterotrophic assay detects estrogen receptor agonists through increases in uterine weight. The advantages of the uterotrophic rat models (immature vs. adult ovariectomized) and exposure routes are discussed. Across 29 studies, relative differences in uterine weights in the vehicle control group and 17α-ethynylestradiol–positive control group were reasonably reproducible. The Hershberger assay detects androgen receptor (AR) agonists, antagonists, and 5α-reductase inhibitors through changes in accessory sex tissue (AST) weights. Across 23 studies, AST weights were relatively reproducible for the vehicle groups (baseline), testosterone propionate (TP) groups (androgenic response), and flutamide + TP groups (antiandrogenic response). In one laboratory, one and four compounds were positive in the androgenic and antiandrogenic portions of the assay, respectively. Each compound was also positive for AR binding. In the other laboratory, three compounds showed potential antiandrogenic activity, but each compound was negative for AR binding and did not fit the profile for 5α-reductase inhibition. These compounds induced hepatic enzymes that enhanced testosterone metabolism/clearance, resulting in lower testosterone and decreased capacity to maintain AST weights. The Hershberger androgenic and antiandrogenic performance criteria were generally attainable. Overall, the uterotrophic and Hershberger assays were easily adopted and function as described for EDSP screening, although the mode of action for positive results may not be easily determined. PMID:24515841

  14. Development of a rapid, simple assay of plasma total carotenoids

    PubMed Central

    2012-01-01

    Background Plasma total carotenoids can be used as an indicator of risk of chronic disease. Laboratory analysis of individual carotenoids by high performance liquid chromatography (HPLC) is time consuming, expensive, and not amenable to use beyond a research laboratory. The aim of this research is to establish a rapid, simple, and inexpensive spectrophotometric assay of plasma total carotenoids that has a very strong correlation with HPLC carotenoid profile analysis. Results Plasma total carotenoids from 29 volunteers ranged in concentration from 1.2 to 7.4 μM, as analyzed by HPLC. A linear correlation was found between the absorbance at 448 nm of an alcohol / heptane extract of the plasma and plasma total carotenoids analyzed by HPLC, with a Pearson correlation coefficient of 0.989. The average coefficient of variation for the spectrophotometric assay was 6.5% for the plasma samples. The limit of detection was about 0.3 μM and was linear up to about 34 μM without dilution. Correlations between the integrals of the absorption spectra in the range of carotenoid absorption and total plasma carotenoid concentration gave similar results to the absorbance correlation. Spectrophotometric assay results also agreed with the calculated expected absorbance based on published extinction coefficients for the individual carotenoids, with a Pearson correlation coefficient of 0.988. Conclusion The spectrophotometric assay of total carotenoids strongly correlated with HPLC analysis of carotenoids of the same plasma samples and expected absorbance values based on extinction coefficients. This rapid, simple, inexpensive assay, when coupled with the carotenoid health index, may be useful for nutrition intervention studies, population cohort studies, and public health interventions. PMID:23006902

  15. CLSI-based transference of CALIPER pediatric reference intervals to Beckman Coulter AU biochemical assays.

    PubMed

    Abou El Hassan, Mohamed; Stoianov, Alexandra; Araújo, Petra A T; Sadeghieh, Tara; Chan, Man Khun; Chen, Yunqi; Randell, Edward; Nieuwesteeg, Michelle; Adeli, Khosrow

    2015-11-01

    The CALIPER program has established a comprehensive database of pediatric reference intervals using largely the Abbott ARCHITECT biochemical assays. To expand clinical application of CALIPER reference standards, the present study is aimed at transferring CALIPER reference intervals from the Abbott ARCHITECT to Beckman Coulter AU assays. Transference of CALIPER reference intervals was performed based on the CLSI guidelines C28-A3 and EP9-A2. The new reference intervals were directly verified using up to 100 reference samples from the healthy CALIPER cohort. We found a strong correlation between Abbott ARCHITECT and Beckman Coulter AU biochemical assays, allowing the transference of the vast majority (94%; 30 out of 32 assays) of CALIPER reference intervals previously established using Abbott assays. Transferred reference intervals were, in general, similar to previously published CALIPER reference intervals, with some exceptions. Most of the transferred reference intervals were sex-specific and were verified using healthy reference samples from the CALIPER biobank based on CLSI criteria. It is important to note that the comparisons performed between the Abbott and Beckman Coulter assays make no assumptions as to assay accuracy or which system is more correct/accurate. The majority of CALIPER reference intervals were transferrable to Beckman Coulter AU assays, allowing the establishment of a new database of pediatric reference intervals. This further expands the utility of the CALIPER database to clinical laboratories using the AU assays; however, each laboratory should validate these intervals for their analytical platform and local population as recommended by the CLSI. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  16. A real-time polymerase chain reaction assay for the detection of Mycoplasma agalactiae.

    PubMed

    Fitzmaurice, J; Sewell, M; King, C M; McDougall, S; McDonald, W L; O'Keefe, J S

    2008-10-01

    To develop a real-time PCR for the detection of Mycoplasma agalactiae, using PCR primers targeting the ma-mp81 gene. A group of 15 M. agalactiae isolates, 21 other Mycoplasma spp. isolates and 21 other bacterial isolates was used in evaluation of the assay. All M. agalactiae isolates were detected by the assay and none of the non-target isolates was amplified. The analytical detection limit of the assay was 10 fg of purified genomic DNA and 104 cfu/ml milk inoculated with M. agalactiae. When applied to goat-milk samples collected from three herds free of M. agalactiae infection, the assay had a specificity of 100%. The assay would be useful in a diagnostic laboratory, providing specific, sensitive and rapid detection of M. agalactiae.

  17. An Electronics "Unit Laboratory"

    ERIC Educational Resources Information Center

    Davies, E. R.; Penton, S. J.

    1976-01-01

    Describes a laboratory teaching technique in which a single topic (in this case, bipolar junction transistors) is studied over a period of weeks under the supervision of one staff member, who also designs the laboratory work. (MLH)

  18. Data Mining Techniques to Estimate Plutonium, Initial Enrichment, Burnup, and Cooling Time in Spent Fuel Assemblies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trellue, Holly Renee; Fugate, Michael Lynn; Tobin, Stephen Joesph

    The Next Generation Safeguards Initiative (NGSI), Office of Nonproliferation and Arms Control (NPAC), National Nuclear Security Administration (NNSA) of the U.S. Department of Energy (DOE) has sponsored a multi-laboratory, university, international partner collaboration to (1) detect replaced or missing pins from spent fuel assemblies (SFA) to confirm item integrity and deter diversion, (2) determine plutonium mass and related plutonium and uranium fissile mass parameters in SFAs, and (3) verify initial enrichment (IE), burnup (BU), and cooling time (CT) of facility declaration for SFAs. A wide variety of nondestructive assay (NDA) techniques were researched to achieve these goals [Veal, 2010 andmore » Humphrey, 2012]. In addition, the project includes two related activities with facility-specific benefits: (1) determination of heat content and (2) determination of reactivity (multiplication). In this research, a subset of 11 integrated NDA techniques was researched using data mining solutions at Los Alamos National Laboratory (LANL) for their ability to achieve the above goals.« less

  19. Cryptosporidium Oocyst Detection in Water Samples: Floatation Technique Enhanced with Immunofluorescence Is as Effective as Immunomagnetic Separation Method

    PubMed Central

    Koompapong, Khuanchai; Sutthikornchai, Chantira

    2009-01-01

    Cryptosporidium can cause gastrointestinal diseases worldwide, consequently posing public health problems and economic burden. Effective techniques for detecting contaminated oocysts in water are important to prevent and control the contamination. Immunomagnetic separation (IMS) method has been widely employed recently due to its efficiency, but, it is costly. Sucrose floatation technique is generally used for separating organisms by using their different specific gravity. It is effective and cheap but time consuming as well as requiring highly skilled personnel. Water turbidity and parasite load in water sample are additional factors affecting to the recovery rate of those 2 methods. We compared the efficiency of IMS and sucrose floatation methods to recover the spiked Cryptosporidium oocysts in various turbidity water samples. Cryptosporidium oocysts concentration at 1, 101, 102, and 103 per 10 µl were spiked into 3 sets of 10 ml-water turbidity (5, 50, and 500 NTU). The recovery rate of the 2 methods was not different. Oocyst load at the concentration < 102 per 10 ml yielded unreliable results. Water turbidity at 500 NTU decreased the recovery rate of both techniques. The combination of sucrose floatation and immunofluorescense assay techniques (SF-FA) showed higher recovery rate than IMS and immunofluorescense assay (IMS-FA). We used this SF-FA to detect Cryptosporidium and Giardia from the river water samples and found 9 and 19 out of 30 (30% and 63.3%) positive, respectively. Our results favored sucrose floatation technique enhanced with immunofluorescense assay for detecting contaminated protozoa in water samples in general laboratories and in the real practical setting. PMID:19967082

  20. Cryptosporidium oocyst detection in water samples: floatation technique enhanced with immunofluorescence is as effective as immunomagnetic separation method.

    PubMed

    Koompapong, Khuanchai; Sutthikornchai, Chantira; Sukthana, Yowalark

    2009-12-01

    Cryptosporidium can cause gastrointestinal diseases worldwide, consequently posing public health problems and economic burden. Effective techniques for detecting contaminated oocysts in water are important to prevent and control the contamination. Immunomagnetic separation (IMS) method has been widely employed recently due to its efficiency, but, it is costly. Sucrose floatation technique is generally used for separating organisms by using their different specific gravity. It is effective and cheap but time consuming as well as requiring highly skilled personnel. Water turbidity and parasite load in water sample are additional factors affecting to the recovery rate of those 2 methods. We compared the efficiency of IMS and sucrose floatation methods to recover the spiked Cryptosporidium oocysts in various turbidity water samples. Cryptosporidium oocysts concentration at 1, 10(1), 10(2), and 10(3) per 10 microl were spiked into 3 sets of 10 ml-water turbidity (5, 50, and 500 NTU). The recovery rate of the 2 methods was not different. Oocyst load at the concentration < 10(2) per 10 ml yielded unreliable results. Water turbidity at 500 NTU decreased the recovery rate of both techniques. The combination of sucrose floatation and immunofluorescense assay techniques (SF-FA) showed higher recovery rate than IMS and immunofluorescense assay (IMS-FA). We used this SF-FA to detect Cryptosporidium and Giardia from the river water samples and found 9 and 19 out of 30 (30% and 63.3%) positive, respectively. Our results favored sucrose floatation technique enhanced with immunofluorescense assay for detecting contaminated protozoa in water samples in general laboratories and in the real practical setting.

  1. Human low density lipoprotein as a substrate for in vitro steroidogenesis assays with fathead minnow ovary explants

    EPA Science Inventory

    Gonad explant in vitro steroidogenesis assays are used as part of a multifaceted strategy to detect endocrine active chemicals capable of altering steroid hormone synthesis. An in vitro steroidogenesis assay used in our laboratory involves exposing fathead minnow (FHM) gonad exp...

  2. Laboratory Assays in Evaluation of Lynch Syndrome in Patients with Endometrial Carcinoma.

    PubMed

    Djordjevic, Bojana; Broaddus, Russell R

    2016-06-01

    This article reviews the main tissue testing modalities for Lynch Syndrome in the pathology laboratory, such as immunohistochemistry and PCR based analyses, and discusses their routine application, interpretation pitfalls, and troubleshooting of common technical performance issues. Discrepancies between laboratory and genetic testing may arise, and are examined in the context of the complexity of molecular abnormalities associated with Lynch Syndrome. The merits of targeted versus universal screening in a changing healthcare climate are addressed. In the absence of comprehensive screening programs, specific tumor topography and histological features that may prompt pathologist-initiated molecular tumor testing are outlined. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Chemistry laboratory safety manual available

    NASA Technical Reports Server (NTRS)

    Elsbrock, R. G.

    1968-01-01

    Chemistry laboratory safety manual outlines safe practices for handling hazardous chemicals and chemistry laboratory equipment. Included are discussions of chemical hazards relating to fire, health, explosion, safety equipment and procedures for certain laboratory techniques and manipulations involving glassware, vacuum equipment, acids, bases, and volatile solvents.

  4. Toward a microfluidic-based rapid amylase assay system.

    PubMed

    Holmes, Richard J; Summersgil, Philip; Ryan, Timothy; Brown, Bernard J Treves; Mockbil, Amal; Grieve, Bruce D; Fielden, Peter R

    2009-08-01

    This article describes work into a prototype system for the assay of amylase, using microfludic technologies. The new system has a significantly shorter cycle time than the current laboratory methods, which generally use microtitre plates, yet is capable of generating significantly superior results. As such, we have shown that sensitivity is enhanced by a factor of 10 in the standard assay trials, and by a factor of 2 in the real-sample lab trials. In both assays, the use of a microreactor system reduced the reaction time by a factor of 6.2, from 20 min incubation to 3.2 min. Basing the conclusion on the Megazyme Cerealpha Standard Method, and using the Cerealpha units as a measure of assay efficiency, the typical response for the microfluidic assay was shown to be 1.0 x 10(-3) CU/mL (standard deviation [SD] 2.5 x 10(-4) CU/mL), compared to 2.56 x 10(-4) CU/mL (SD 5.94 x 10(-5) CU/mL) for the standard macroassay. It is believed that this improvement in the reaction schematics is due to the inherent advantages of microfluidic devices such as superior mixing, higher thermal efficiency, and enhanced reaction kinetics.

  5. Analytical techniques for steroid estrogens in water samples - A review.

    PubMed

    Fang, Ting Yien; Praveena, Sarva Mangala; deBurbure, Claire; Aris, Ahmad Zaharin; Ismail, Sharifah Norkhadijah Syed; Rasdi, Irniza

    2016-12-01

    In recent years, environmental concerns over ultra-trace levels of steroid estrogens concentrations in water samples have increased because of their adverse effects on human and animal life. Special attention to the analytical techniques used to quantify steroid estrogens in water samples is therefore increasingly important. The objective of this review was to present an overview of both instrumental and non-instrumental analytical techniques available for the determination of steroid estrogens in water samples, evidencing their respective potential advantages and limitations using the Need, Approach, Benefit, and Competition (NABC) approach. The analytical techniques highlighted in this review were instrumental and non-instrumental analytical techniques namely gas chromatography mass spectrometry (GC-MS), liquid chromatography mass spectrometry (LC-MS), enzyme-linked immuno sorbent assay (ELISA), radio immuno assay (RIA), yeast estrogen screen (YES) assay, and human breast cancer cell line proliferation (E-screen) assay. The complexity of water samples and their low estrogenic concentrations necessitates the use of highly sensitive instrumental analytical techniques (GC-MS and LC-MS) and non-instrumental analytical techniques (ELISA, RIA, YES assay and E-screen assay) to quantify steroid estrogens. Both instrumental and non-instrumental analytical techniques have their own advantages and limitations. However, the non-instrumental ELISA analytical techniques, thanks to its lower detection limit and simplicity, its rapidity and cost-effectiveness, currently appears to be the most reliable for determining steroid estrogens in water samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Development of a real-time quantitative PCR assay to enumerate Yersinia pestis in fleas.

    PubMed

    Gabitzsch, Elizabeth S; Vera-Tudela, Rommelle; Eisen, Rebecca J; Bearden, Scott W; Gage, Kenneth L; Zeidner, Nordin S

    2008-07-01

    A real-time quantitative polymerase chain reaction (qPCR) assay was developed for Yersina pestis. The qPCR assay was developed utilizing a conserved region of the Y. pestis ferric iron uptake regulator gene (fur) to design primers and a fluorescent (FAM-labeled) TaqMan probe. The assay was optimized using cultured Y. pestis (UG05-0454) and was confirmed to work with strains from 3 Y. pestis biovars. The optimized assay was capable of detecting a single organism of cultured Y. pestis and as little as 300 bacteria in infected flea triturates. This qPCR assay enables rapid enumeration of Y. pestis bacterium in laboratory-infected fleas when compared with conventional serial dilution plating.

  7. Laboratory tests for diagnosis of food allergy: advantages, disadvantages and future perspectives.

    PubMed

    Moneret-Vautrin, D A; Kanny, G; Frémont, S

    2003-04-01

    Numerous biological tests point to the diagnosis of food sensitization: detection of specific IgEs by Rast techniques, multi-detection assays, immunoblotting, screening of basophil activation (BAT or FAST), assays for leukotriene LTC4 release (CAST), measurement of plasma histamine, serum tryptase, serum ECP, urinary EDN, completed by mannitol-lactulose test evaluating intestinal permeability, assay of fecal IgEs, Rast for specific IgG4. Primary screening for anti-food IgEs by multi-detection assays seeks justification from insufficient clinical data and false positive tests are common in patients sensitized to pollens or latex, on account of in vitro cross reactivities (CR). Multiple CR explain positive Rast to vegetal food allergens in such patients. Biological tests should not be performed as the first line of diagnosis. In vivo sensitisation is assessed by positive prick-tests, demonstrating the bivalence of allergens, as well as the affinity of specific IgEs, two conditions necessary to bridge membrane bound specific IgEs, leading to the release of mediators. Prick-tests are closer to clinical symptoms than biological tests. However, the diagnosis of food allergy is based on standardised oral challenges. Exceptions are high levels of specific IgEs to egg (> 6 kUl/l), peanut (> 15 kUl/l), fish (> 20 kUl/l) and milk (> 32 kUl/l), reaching a 95% predictive positive value. Rast inhibition tests are useful to identify masked allergens in foods. Research developments will have impact on the development of new diagnostic tools: allergen mixes reinforcing a food extract by associated recombinant major allergens, multiple combination of recombinant allergens (chips) or tests with synthetic epitopes aimed a the prediction of recovery. Laboratory tests take place in the decision free for the diagnosis for the food allergy and the follow-up of the levels specific IgEs is a tool to assess outcome and contributes to predict recovery or persistent allergy. Up to now the

  8. Engineering of a miniaturized, robotic clinical laboratory

    PubMed Central

    Nourse, Marilyn B.; Engel, Kate; Anekal, Samartha G.; Bailey, Jocelyn A.; Bhatta, Pradeep; Bhave, Devayani P.; Chandrasekaran, Shekar; Chen, Yutao; Chow, Steven; Das, Ushati; Galil, Erez; Gong, Xinwei; Gessert, Steven F.; Ha, Kevin D.; Hu, Ran; Hyland, Laura; Jammalamadaka, Arvind; Jayasurya, Karthik; Kemp, Timothy M.; Kim, Andrew N.; Lee, Lucie S.; Liu, Yang Lily; Nguyen, Alphonso; O'Leary, Jared; Pangarkar, Chinmay H.; Patel, Paul J.; Quon, Ken; Ramachandran, Pradeep L.; Rappaport, Amy R.; Roy, Joy; Sapida, Jerald F.; Sergeev, Nikolay V.; Shee, Chandan; Shenoy, Renuka; Sivaraman, Sharada; Sosa‐Padilla, Bernardo; Tran, Lorraine; Trent, Amanda; Waggoner, Thomas C.; Wodziak, Dariusz; Yuan, Amy; Zhao, Peter; Holmes, Elizabeth A.

    2018-01-01

    Abstract The ability to perform laboratory testing near the patient and with smaller blood volumes would benefit patients and physicians alike. We describe our design of a miniaturized clinical laboratory system with three components: a hardware platform (ie, the miniLab) that performs preanalytical and analytical processing steps using miniaturized sample manipulation and detection modules, an assay‐configurable cartridge that provides consumable materials and assay reagents, and a server that communicates bidirectionally with the miniLab to manage assay‐specific protocols and analyze, store, and report results (i.e., the virtual analyzer). The miniLab can detect analytes in blood using multiple methods, including molecular diagnostics, immunoassays, clinical chemistry, and hematology. Analytical performance results show that our qualitative Zika virus assay has a limit of detection of 55 genomic copies/ml. For our anti‐herpes simplex virus type 2 immunoglobulin G, lipid panel, and lymphocyte subset panel assays, the miniLab has low imprecision, and method comparison results agree well with those from the United States Food and Drug Administration‐cleared devices. With its small footprint and versatility, the miniLab has the potential to provide testing of a range of analytes in decentralized locations. PMID:29376134

  9. Tritium laboratory with multiple purposes at NIPNE Magurele Romania

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matei, L.; Postolache, C.

    2008-07-15

    The Tritium Laboratory from NIPNE (Romania)) is part of Radioisotope Research and Production Center. The Tritium Laboratory has been in operation since 1960, and carries out R and D activities involving tritium sources in gaseous, liquids and solid state, provides specialized service to CANDU NPP Cernavoda (Romania)), and provides tritium assay services to internal and external customers. The paper presents the activities and perspectives of Tritium Laboratory and its performances in accordance with Quality System Management. (authors)

  10. Carboxyhaemoglobin: a possible reference material for haemoglobin assay.

    PubMed Central

    Rideout, J M; Louderback, A

    1982-01-01

    The inter- and intralaboratory quality control of haemoglobin estimation in remote laboratories requires a more rugged control haemolysate than is commercially available. The stabilities of oxyhaemoglobin and carboxyhaemoglobin forms of an ethanediol-containing haemolysate were studied over a three-year period. From the results obtained, carboxyhaemoglobin under nitrogen is proposed as a possible candidate reference material for haemoglobin assay. PMID:7068921

  11. Investigation of Phototriangulation Accuracy with Using of Various Techniques Laboratory and Field Calibration

    NASA Astrophysics Data System (ADS)

    Chibunichev, A. G.; Kurkov, V. M.; Smirnov, A. V.; Govorov, A. V.; Mikhalin, V. A.

    2016-10-01

    Nowadays, aerial survey technology using aerial systems based on unmanned aerial vehicles (UAVs) becomes more popular. UAVs physically can not carry professional aerocameras. Consumer digital cameras are used instead. Such cameras usually have rolling, lamellar or global shutter. Quite often manufacturers and users of such aerial systems do not use camera calibration. In this case self-calibration techniques are used. However such approach is not confirmed by extensive theoretical and practical research. In this paper we compare results of phototriangulation based on laboratory, test-field or self-calibration. For investigations we use Zaoksky test area as an experimental field provided dense network of target and natural control points. Racurs PHOTOMOD and Agisoft PhotoScan software were used in evaluation. The results of investigations, conclusions and practical recommendations are presented in this article.

  12. Laboratory measurement of apixaban using anti-factor Xa assays in acute ischemic stroke patients with non-valvular atrial fibrillation.

    PubMed

    Shin, Hyoshim; Cho, Min-Chul; Kim, Rock Bum; Kim, Chang-Hun; Choi, Nack-Cheon; Kim, Soo-Kyung; Koh, Eun-Ha

    2018-02-01

    Apixaban is effective and safe for preventing stroke, and its usage has increased exponentially in recent years. However, data concerning the therapeutic range of apixaban is limited. This study determined the trough and peak levels of apixaban-specific anti-factor Xa activity (AFXaA) in acute ischemic stroke patients with non-valvular atrial fibrillation (NVAF) in Korea. The study included 85 patients who received apixaban. Blood samples were taken to measure the trough and peak levels of AFXaA using a chromogenic anti-factor assay, as well as prothrombin time (PT) and activated partial thromboplastin time (aPTT). We also reviewed complications such as major bleeding of patients treated with apixaban. In patients given a 5.0-mg apixaban dose, the median trough and peak levels of AFXaA were 104.5 and 202.0 ng/mL. In patients given a 2.5-mg apixaban dose, the median trough and peak AFXaA levels were 76.0 and 151.0 ng/mL. The PT showed a positive correlation with increased AFXaA activity at both levels (Trough R = 0.486, Peak R = 0.592), but the aPTT had no relationship with AFXaA activity at both levels (Trough R = 0.181, Peak R = 0.129). Two cases with intracranial bleeding belonged to the highest AFXaA quartile (Trough, p = 0.176; Peak, p = 0.053). In conclusion, we determined the trough and peak levels of AFXaA in patients with NVAF while being treated with the apixaban in Korea. Our results could be used as a starting point when setting the reference ranges for laboratories using anti-Xa assay. Large-scale studies are needed to establish the reference range for AFXaA in patients with NVAF.

  13. Validation conform ISO-15189 of assays in the field of autoimmunity: Joint efforts in The Netherlands.

    PubMed

    Mulder, Leontine; van der Molen, Renate; Koelman, Carin; van Leeuwen, Ester; Roos, Anja; Damoiseaux, Jan

    2018-05-01

    ISO 15189:2012 requires validation of methods used in the medical laboratory, and lists a series of performance parameters for consideration to include. Although these performance parameters are feasible for clinical chemistry analytes, application in the validation of autoimmunity tests is a challenge. Lack of gold standards or reference methods in combination with the scarcity of well-defined diagnostic samples of patients with rare diseases make validation of new assays difficult. The present manuscript describes the initiative of Dutch medical immunology laboratory specialists to combine efforts and perform multi-center validation studies of new assays in the field of autoimmunity. Validation data and reports are made available to interested Dutch laboratory specialists. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Digital microfluidic platform for multiplexing enzyme assays: implications for lysosomal storage disease screening in newborns.

    PubMed

    Sista, Ramakrishna S; Eckhardt, Allen E; Wang, Tong; Graham, Carrie; Rouse, Jeremy L; Norton, Scott M; Srinivasan, Vijay; Pollack, Michael G; Tolun, Adviye A; Bali, Deeksha; Millington, David S; Pamula, Vamsee K

    2011-10-01

    Newborn screening for lysosomal storage diseases (LSDs) has been gaining considerable interest owing to the availability of enzyme replacement therapies. We present a digital microfluidic platform to perform rapid, multiplexed enzymatic analysis of acid α-glucosidase (GAA) and acid α-galactosidase to screen for Pompe and Fabry disorders. The results were compared with those obtained using standard fluorometric methods. We performed bench-based, fluorometric enzymatic analysis on 60 deidentified newborn dried blood spots (DBSs), plus 10 Pompe-affected and 11 Fabry-affected samples, at Duke Biochemical Genetics Laboratory using a 3-mm punch for each assay and an incubation time of 20 h. We used a digital microfluidic platform to automate fluorometric enzymatic assays at Advanced Liquid Logic Inc. using extract from a single punch for both assays, with an incubation time of 6 h. Assays were also performed with an incubation time of 1 h. Assay results were generally comparable, although mean enzymatic activity for GAA using microfluidics was approximately 3 times higher than that obtained using bench-based methods, which could be attributed to higher substrate concentration. Clear separation was observed between the normal and affected samples at both 6- and 1-h incubation times using digital microfluidics. A digital microfluidic platform compared favorably with a clinical reference laboratory to perform enzymatic analysis in DBSs for Pompe and Fabry disorders. This platform presents a new technology for a newborn screening laboratory to screen LSDs by fully automating all the liquid-handling operations in an inexpensive system, providing rapid results.

  15. Novel Single Nucleotide Polymorphism-Based Assay for Genotyping Mycobacterium avium subsp. paratuberculosis

    PubMed Central

    Goldstone, Robert J.; McLuckie, Joyce; Smith, David G. E.

    2015-01-01

    Typing of Mycobacterium avium subspecies paratuberculosis strains presents a challenge, since they are genetically monomorphic and traditional molecular techniques have limited discriminatory power. The recent advances and availability of whole-genome sequencing have extended possibilities for the characterization of Mycobacterium avium subspecies paratuberculosis, and whole-genome sequencing can provide a phylogenetic context to facilitate global epidemiology studies. In this study, we developed a single nucleotide polymorphism (SNP) assay based on PCR and restriction enzyme digestion or sequencing of the amplified product. The SNP analysis was performed using genome sequence data from 133 Mycobacterium avium subspecies paratuberculosis isolates with different genotypes from 8 different host species and 17 distinct geographic regions around the world. A total of 28,402 SNPs were identified among all of the isolates. The minimum number of SNPs required to distinguish between all of the 133 genomes was 93 and between only the type C isolates was 41. To reduce the number of SNPs and PCRs required, we adopted an approach based on sequential detection of SNPs and a decision tree. By the analysis of 14 SNPs Mycobacterium avium subspecies paratuberculosis isolates can be characterized within 14 phylogenetic groups with a higher discriminatory power than mycobacterial interspersed repetitive unit–variable number tandem repeat assay and other typing methods. Continuous updating of genome sequences is needed in order to better characterize new phylogenetic groups and SNP profiles. The novel SNP assay is a discriminative, simple, reproducible method and requires only basic laboratory equipment for the large-scale global typing of Mycobacterium avium subspecies paratuberculosis isolates. PMID:26677250

  16. Fluorescence lifetime assays: current advances and applications in drug discovery.

    PubMed

    Pritz, Stephan; Doering, Klaus; Woelcke, Julian; Hassiepen, Ulrich

    2011-06-01

    Fluorescence lifetime assays complement the portfolio of established assay formats available in drug discovery, particularly with the recent advances in microplate readers and the commercial availability of novel fluorescent labels. Fluorescence lifetime assists in lowering complexity of compound screening assays, affording a modular, toolbox-like approach to assay development and yielding robust homogeneous assays. To date, materials and procedures have been reported for biochemical assays on proteases, as well as on protein kinases and phosphatases. This article gives an overview of two assay families, distinguished by the origin of the fluorescence signal modulation. The pharmaceutical industry demands techniques with a robust, integrated compound profiling process and short turnaround times. Fluorescence lifetime assays have already helped the drug discovery field, in this sense, by enhancing productivity during the hit-to-lead and lead optimization phases. Future work will focus on covering other biochemical molecular modifications by investigating the detailed photo-physical mechanisms underlying the fluorescence signal.

  17. Lessons from Astrobiological Planetary Analogue Exploration in Iceland: Biomarker Assay Performance and Downselection

    NASA Technical Reports Server (NTRS)

    Gentry, D. M.; Amador, E. S.; Cable, M. L.; Cantrell, T.; Chaudry, N.; Cullen, T.; Duca, Z.; Kirby, J.; Jacobsen, M.; McCaig, H.; hide

    2017-01-01

    Understanding the sensitivity of biomarker assays to the local physicochemical environment, and the underlying spatial distribution of the target biomarkers in 'homogeneous' environments, can increase mission science return. We have conducted four expeditions to Icelandic Mars analogue sites in which an increasingly refined battery of physicochemical measurements and biomarker assays were performed, staggered with scouting of further sites. Completed expeditions took place in 2012 (location scouting and field assay use testing), 2013 (sampling of two major sites with three assays and observational physicochemical measurements), 2015 (repeat sampling of prior sites and one new site, scouting of new sites, three assays and three instruments), and 2016 (preliminary sampling of new sites with analysis of returned samples). Target sites were geologically recent basaltic lava flows, and sample loci were arranged in hierarchically nested grids at 10 cm, 1 m, 10 m, 100 m, and >1 km order scales, subject to field constraints. Assays were intended to represent a diversity of potential biomarker types (cell counting via nucleic acid staining and fluorescence microscopy, ATP quantification via luciferase luminescence, and relative DNA quantification with simple domain-level primers) rather a specific mission science target, and were selected to reduce laboratory overhead, require limited consumables, and allow rapid turnaround. All analytical work was performed in situ or in a field laboratory within a day's travel of the field sites unless otherwise noted. We have demonstrated the feasibility of performing ATP quantification and qPCR analysis in a field-based laboratory with single-day turnaround. The ATP assay was generally robust and reliable and required minimal field equipment and training to produce a large amount of useful data. DNA was successfully extracted from all samples, but the serial-batch nature of qPCR significantly limited the number of primers (hence

  18. Cellobiohydrolase (CBH) Activity Assays.

    PubMed

    Sharma, Hem Kanta; Qin, Wensheng; Xu, Chunbao Charles

    2018-01-01

    Cellulosic biomass is the most abundant biopolymer on the earth. It has great potential to quench the thirst of liquid energy by producing biofuels and thus help to mitigate human reliance on fossil fuels. Although several cellulase activity assay methods have been used to disintegrate the glycosidic bonds, the appropriate selection of substrates and synergistic involvement of multiple enzymes in hydrolytic activity is not yet fully understood. The proper quantification of hydrolytic enzymes and hydrolysates is challenging because of the heterogeneity of cellulose, changes in enzyme-substrate ratio and the presence of some inhibitory compounds like cellobiose and cellodextran. In the glycosyl hydrolase (GH) family, cellobiohydrolase (CBH) is expected to disrupt the crystalline cellulose and release the sugar molecules. Several methods have been proposed for CBH assay with slight modification in substrate and quantification of hydrolysates. However, the Avicel method is still considered as the most promising and efficient hydrolytic technique so far. The most commonly used CBH assays including Avicel and other recent methods for proper quantification are outlined in this chapter. Also a qualitative screening of CBH producing bacteria using carboxymethyl cellulose (CMC) agar plates is described.

  19. Optical characterization of Chinese hybrid rice using laser-induced fluorescence techniques-laboratory and remote-sensing measurements.

    PubMed

    Duan, Zheng; Peng, Ting; Zhu, Shiming; Lian, Ming; Li, Yiyun; Wei, Fu; Xiong, Jiabao; Svanberg, Sune; Zhao, Quanzhi; Hu, Jiandong; Zhao, Guangyu

    2018-05-01

    Chinese hybrid rice of different varieties, growing in paddies in the Pingqiao district, north of Xinyang city, Henan province, China, was studied in detailed spectroscopic characteristics using laser-induced fluorescence. The base for the studies was the new South China Normal University mobile lidar laboratory, which was dispatched on site, providing facilities both for laboratory studies using a 405 nm excitation source as well as remote sensing measurements at ranges from around 40 m-120 m, mostly employing the 532 nm output from a Nd:YAG laser. We, in particular, studied the spectral influence of the species varieties as well as the level of nitrogen fertilization supplied. Specially developed contrast functions as well as multivariate techniques with principal components and Fisher's discriminate analyses were applied, and useful characterization of the rice could be achieved. The chlorophyll content mapping of the 30 zones was obtained with the remote sensing measurements.

  20. Protein biomarker validation via proximity ligation assays.

    PubMed

    Blokzijl, A; Nong, R; Darmanis, S; Hertz, E; Landegren, U; Kamali-Moghaddam, M

    2014-05-01

    The ability to detect minute amounts of specific proteins or protein modifications in blood as biomarkers for a plethora of human pathological conditions holds great promise for future medicine. Despite a large number of plausible candidate protein biomarkers published annually, the translation to clinical use is impeded by factors such as the required size of the initial studies, and limitations of the technologies used. The proximity ligation assay (PLA) is a versatile molecular tool that has the potential to address some obstacles, both in validation of biomarkers previously discovered using other techniques, and for future routine clinical diagnostic needs. The enhanced specificity of PLA extends the opportunities for large-scale, high-performance analyses of proteins. Besides advantages in the form of minimal sample consumption and an extended dynamic range, the PLA technique allows flexible assay reconfiguration. The technology can be adapted for detecting protein complexes, proximity between proteins in extracellular vesicles or in circulating tumor cells, and to address multiple post-translational modifications in the same protein molecule. We discuss herein requirements for biomarker validation, and how PLA may play an increasing role in this regard. We describe some recent developments of the technology, including proximity extension assays, the use of recombinant affinity reagents suitable for use in proximity assays, and the potential for single cell proteomics. This article is part of a Special Issue entitled: Biomarkers: A Proteomic Challenge. © 2013.

  1. Growth hormone: its measurement and the need for assay harmonization.

    PubMed

    Wood, P

    2001-09-01

    Serum human growth hormone (hGH) assays show a wide range in bias and in cut-off values for provocative tests, which vary from 13.5 to 35-40 mU/L when they have been established. Studies using novel hGH assays show that methods that are absolutely specific for 22-kDa hGH may not identify bioactive hGH peaks and that 20:22-kDa hGH ratios are increased in acromegaly. Greater harmonization of serum hGH methods can be achieved by: changing from IS 80/505 to IS 98/574, which is calibrated in mass units of recombinant 22-kDa hGH; using monoclonal/polyclonal or polyclonal/polyclonal antibody combinations that measure both 20-kDa and 22-kDa hGH; the development of assays such as the immunofunctional hGH assay which has the convenience of an immunometric assay but gives results that correlate better with bioassays collaboration between manufacturers and laboratories to establish method-related cut-off limits for provocative tests of hGH status.

  2. Microwave remote sensing laboratory design

    NASA Technical Reports Server (NTRS)

    Friedman, E.

    1979-01-01

    Application of active and passive microwave remote sensing to the study of ocean pollution is discussed. Previous research efforts, both in the field and in the laboratory were surveyed to derive guidance for the design of a laboratory program of research. The essential issues include: choice of radar or radiometry as the observational technique; choice of laboratory or field as the research site; choice of operating frequency; tank sizes and material; techniques for wave generation and appropriate wavelength spectrum; methods for controlling and disposing of pollutants used in the research; and pollutants other than oil which could or should be studied.

  3. Diets, equipment, and techniques for maintaining crawfish in the laboratory

    USGS Publications Warehouse

    Tarshis, I.B.; Avault, James W.

    1978-01-01

    One commercial and 4 laboratory prepared extruded, water-stable diets were fed 3 times a week in 1-g portions to juvenile male and female White River crawfish, Procambarus acutus acutus (Girard), for 10 weeks. The. binding material in the laboratory preparation was alginate (Kelgin), whereas that in the commercial preparation was starch. No statistically significant weight differences developed between the groups of crawfish at the end of the 10-week period; all 5 diets were found satisfactory for feeding and maintaining P. acutus acutus in the laboratory, and all test crawfish survived throughout the experimental period. Weight gains were highest in a diet containing 50.5% protein; intermediate in those fed a diet with 46.0% protein; and lowest in those fed diets with 31.7 or 36.3% protein. Crawfish fed the commercial preparation of one of the 46.0% protein diets showed a slightly but not significantly higher weight gain than those fed the laboratory preparation of the diet. In an evaluation of the water stability of 5 commercially prepared animal chow diets and the commercial extruded diet, 2 of the commercial diets disintegrated after one hour exposure in water and the other 3 became bloated after one hour and remained on the surface throughout the 24-hour test. The commercial extruded diet maintained its water stability for the full 24 hours. The commercial preparation of the 46.0% protein diet was successfully used under laboratory conditions for feeding and maintaining the following crawfishes: Cambarellus shufeldtii (Faxon), Cambarus acuminatus Faxon, Orconectes limosus (Rafinesque), O. virilis (Hagen), Procambarus clarkii (Girard), and P. spiculifer (Le conte). In longevity experiments Cambarus diogenes diogenes Girard and Procambarus hinei (Ortmann) now have survived for 8 months on this diet in the laboratory.

  4. Key learnings from the Endocrine Disruptor Screening Program (EDSP) Tier 1 rodent uterotrophic and Hershberger assays.

    PubMed

    Marty, M Sue; O'Connor, John C

    2014-02-01

    In 2009, companies began screening compounds using the US Environmental Protection Agency's Endocrine Disruptor Screening Program (EDSP). EDSP has two tiers: Tier 1 includes 11 assays to identify compounds with potential endocrine activity. This article describes two laboratories' experiences conducting Tier 1 uterotrophic and Hershberger assays. The uterotrophic assay detects estrogen receptor agonists through increases in uterine weight. The advantages of the uterotrophic rat models (immature vs. adult ovariectomized) and exposure routes are discussed. Across 29 studies, relative differences in uterine weights in the vehicle control group and 17α-ethynylestradiol-positive control group were reasonably reproducible. The Hershberger assay detects androgen receptor (AR) agonists, antagonists, and 5α-reductase inhibitors through changes in accessory sex tissue (AST) weights. Across 23 studies, AST weights were relatively reproducible for the vehicle groups (baseline), testosterone propionate (TP) groups (androgenic response), and flutamide + TP groups (antiandrogenic response). In one laboratory, one and four compounds were positive in the androgenic and antiandrogenic portions of the assay, respectively. Each compound was also positive for AR binding. In the other laboratory, three compounds showed potential antiandrogenic activity, but each compound was negative for AR binding and did not fit the profile for 5α-reductase inhibition. These compounds induced hepatic enzymes that enhanced testosterone metabolism/clearance, resulting in lower testosterone and decreased capacity to maintain AST weights. The Hershberger androgenic and antiandrogenic performance criteria were generally attainable. Overall, the uterotrophic and Hershberger assays were easily adopted and function as described for EDSP screening, although the mode of action for positive results may not be easily determined. © 2014 Wiley Periodicals, Inc.

  5. Differences in Ultrasonic Vocalizations between Wild and Laboratory California Mice (Peromyscus californicus)

    PubMed Central

    Kalcounis-Rueppell, Matina C.; Petric, Radmila; Briggs, Jessica R.; Carney, Catherine; Marshall, Matthew M.; Willse, John T.; Rueppell, Olav; Ribble, David O.; Crossland, Janet P.

    2010-01-01

    Background Ultrasonic vocalizations (USVs) emitted by muroid rodents, including laboratory mice and rats, are used as phenotypic markers in behavioral assays and biomedical research. Interpretation of these USVs depends on understanding the significance of USV production by rodents in the wild. However, there has never been a study of muroid rodent ultrasound function in the wild and comparisons of USVs produced by wild and laboratory rodents are lacking to date. Here, we report the first comparison of wild and captive rodent USVs recorded from the same species, Peromyscus californicus. Methodology and Principal Findings We used standard ultrasound recording techniques to measure USVs from California mice in the laboratory (Peromyscus Genetic Stock Center, SC, USA) and the wild (Hastings Natural History Reserve, CA, USA). To determine which California mouse in the wild was vocalizing, we used a remote sensing method that used a 12-microphone acoustic localization array coupled with automated radio telemetry of all resident Peromyscus californicus in the area of the acoustic localization array. California mice in the laboratory and the wild produced the same types of USV motifs. However, wild California mice produced USVs that were 2–8 kHz higher in median frequency and significantly more variable in frequency than laboratory California mice. Significance The similarity in overall form of USVs from wild and laboratory California mice demonstrates that production of USVs by captive Peromyscus is not an artifact of captivity. Our study validates the widespread use of USVs in laboratory rodents as behavioral indicators but highlights that particular characteristics of laboratory USVs may not reflect natural conditions. PMID:20368980

  6. Validation of STA-Liatest D-Di assay for exclusion of pulmonary embolism according to the latest Clinical and Laboratory Standard Institute/Food and Drug Administration guideline. Results of a multicenter management study.

    PubMed

    Pernod, Gilles; Wu, Haifeng; de Maistre, Emmanuel; Lazarchick, John; Kassis, Jeannine; Aguilar, Carlos; Vera, Pascual M; Palareti, Gualtiero; D'Angelo, Armando

    2017-04-01

    : Combined clinical pretest probability (PTP) and D-dimer testing have great diagnostic value for pulmonary embolism exclusion. To harmonize performance levels of D-dimer assays available on the market, the Clinical and Laboratory Standard Institute (CLSI) has published a guideline, endorsed by the US Food and Drug Administration (FDA). Such guideline specifies the ideal D-dimer assay characteristic and target population. This study was conducted following the CLSI guideline to upgrade the assay-intended use and obtain FDA clearance of STA-Liatest D-Di assay for pulmonary embolism exclusion in patient with low/moderate PTP. This was an international, multicenter, prospective nonrandomized, noninterventional clinical outcome management study conducted in a standard of care setting. D-dimer assay was performed in consecutive, ambulatory outpatients suspected of pulmonary embolism, with low/moderate PTP, and without medical conditions or in clinical settings known to alter default D-dimer values regardless of the presence of thrombosis using a threshold of 0.5 μg/ml (fibrinogen equivalent units) for venous thromboembolism exclusion. Results were used to determine test performance. Of 1141 patients who underwent D-dimer testing, 1060 had valid results and completed study as planned. STA-Liatest D-Di assay performance has exceeded the CLSI/FDA guidance requirements, with a sensitivity of 97.6% (95% confidence interval: 91.7-99.7%) and a negative predictive value of 99.7% (95% confidence interval: 99.0-100%). STA-Liatest D-Di assay has an excellent performance when used in combination with a PTP score in relevant patients and has the potential to minimize the economic healthcare burden avoiding unnecessary and expensive imaging tests.

  7. Flexible Label-Free Quantitative Assay for Antibodies to Influenza Virus Hemagglutinins ▿

    PubMed Central

    Carney, Paul J.; Lipatov, Aleksandr S.; Monto, Arnold S.; Donis, Ruben O.; Stevens, James

    2010-01-01

    During the initial pandemic influenza H1N1 virus outbreak, assays such as hemagglutination inhibition and microneutralization provided important information on the relative protection afforded by the population's cross-reactivity from prior infections and immunizations with seasonal vaccines. However, these assays continue to be limited in that they are difficult to automate for high throughput, such as in pandemic situations, as well as to standardize between labs. Thus, new technologies are being sought to improve standardization, reliability, and throughput by using chemically defined reagents rather than whole cells and virions. We now report the use of a cell-free and label-free flu antibody biosensor assay (f-AbBA) for influenza research and diagnostics that utilizes recombinant hemagglutinin (HA) in conjunction with label-free biolayer interferometry technology to measure biomolecular interactions between the HA and specific anti-HA antibodies or sialylated ligands. We evaluated f-AbBA to determine anti-HA antibody binding activity in serum or plasma to assess vaccine-induced humoral responses. This assay can reveal the impact of antigenic difference on antibody binding to HA and also measure binding to different subtypes of HA. We also show that the biosensor assay can measure the ability of HA to bind a model sialylated receptor-like ligand. f-AbBA could be used in global surveillance laboratories since preliminary tests on desiccated HA probes showed no loss of activity after >2 months in storage at room temperature, indicating that the same reagent lots could be used in different laboratories to minimize interlaboratory assay fluctuation. Future development of such reagents and similar technologies may offer a robust platform for future influenza surveillance activities. PMID:20660137

  8. New method of paired thyrotropin assay as a screening test for neonatal hypothyroidism. [/sup 125/I tracer technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miyai, K.; Oura, T.; Kawashima, M.

    1978-11-01

    A simple and reliable method of paired TSH assay was developed and used in screening for neonatal primary hypothyroidism. In this method, a paired assay is first done. Equal parts of the extracts of dried blood spots on filter paper (9 mm diameter) from two infants 4 to 7 days old are combined and assayed for TSH by double antibody RIA. If the value obtained is over the cut-off point, the extracts are assayed separately for TSH in a second assay to identify the abnormal sample. Two systems, A and B, with different cut-off points were tested. On the basismore » of reference blood samples (serum levels of TSH, 80 ..mu..U/ml in system A and 40 ..mu..U/ml in system B), the cut-off point was selected as follows: upper 5 (A) or 4 (B) percentile in the paired assay and values of reference blood samples in the second individual assay. Four cases (2 in A and 2 in B) of neonatal primary hypothyroidism were found among 25 infants (23 in A and 2 in B) who were recalled from a general population of 41,400 infants (24,200 in A and 17,200 in B) by 22,700 assays. This paired TSH assay system saves labor and expense for screening neonatal hypothyroidism.« less

  9. Using a medium-throughput comet assay to evaluate the global DNA methylation status of single cells

    PubMed Central

    Lewies, Angélique; Van Dyk, Etresia; Wentzel, Johannes F.; Pretorius, Pieter J.

    2014-01-01

    The comet assay is a simple and cost effective technique, commonly used to analyze and quantify DNA damage in individual cells. The versatility of the comet assay allows introduction of various modifications to the basic technique. The difference in the methylation sensitivity of the isoschizomeric restriction enzymes HpaII and MspI are used to demonstrate the ability of the comet assay to measure the global DNA methylation level of individual cells when using cell cultures. In the experiments described here, a medium-throughput comet assay and methylation sensitive comet assay are combined to produce a methylation sensitive medium-throughput comet assay to measure changes in the global DNA methylation pattern in individual cells under various growth conditions. PMID:25071840

  10. Correlative Förster Resonance Electron Transfer-Proximity Ligation Assay (FRET-PLA) Technique for Studying Interactions Involving Membrane Proteins.

    PubMed

    Ivanusic, Daniel; Denner, Joachim; Bannert, Norbert

    2016-08-01

    This unit provides a guide and detailed protocol for studying membrane protein-protein interactions (PPI) using the acceptor-sensitized Förster resonance electron transfer (FRET) method in combination with the proximity ligation assay (PLA). The protocol in this unit is focused on the preparation of FRET-PLA samples and the detection of correlative FRET/PLA signals as well as on the analysis of FRET-PLA data and interpretation of correlative results when using cyan fluorescent protein (CFP) as a FRET donor and yellow fluorescent protein (YFP) as a FRET acceptor. The correlative application of FRET and PLA combines two powerful tools for monitoring PPI, yielding results that are more reliable than with either technique alone. © 2016 by John Wiley & Sons, Inc. Copyright © 2016 John Wiley & Sons, Inc.

  11. Recommended Immunological Assays to Screen for Ricin-Containing Samples.

    PubMed

    Simon, Stéphanie; Worbs, Sylvia; Avondet, Marc-André; Tracz, Dobryan M; Dano, Julie; Schmidt, Lisa; Volland, Hervé; Dorner, Brigitte G; Corbett, Cindi R

    2015-11-26

    Ricin, a toxin from the plant Ricinus communis, is one of the most toxic biological agents known. Due to its availability, toxicity, ease of production and absence of curative treatments, ricin has been classified by the Centers for Disease Control and Prevention (CDC) as category B biological weapon and it is scheduled as a List 1 compound in the Chemical Weapons Convention. An international proficiency test (PT) was conducted to evaluate detection and quantification capabilities of 17 expert laboratories. In this exercise one goal was to analyse the laboratories' capacity to detect and differentiate ricin and the less toxic, but highly homologuous protein R. communis agglutinin (RCA120). Six analytical strategies are presented in this paper based on immunological assays (four immunoenzymatic assays and two immunochromatographic tests). Using these immunological methods "dangerous" samples containing ricin and/or RCA120 were successfully identified. Based on different antibodies used the detection and quantification of ricin and RCA120 was successful. The ricin PT highlighted the performance of different immunological approaches that are exemplarily recommended for highly sensitive and precise quantification of ricin.

  12. Comparative analytical evaluation of the respiratory TaqMan Array Card with real-time PCR and commercial multi-pathogen assays.

    PubMed

    Harvey, John J; Chester, Stephanie; Burke, Stephen A; Ansbro, Marisela; Aden, Tricia; Gose, Remedios; Sciulli, Rebecca; Bai, Jing; DesJardin, Lucy; Benfer, Jeffrey L; Hall, Joshua; Smole, Sandra; Doan, Kimberly; Popowich, Michael D; St George, Kirsten; Quinlan, Tammy; Halse, Tanya A; Li, Zhen; Pérez-Osorio, Ailyn C; Glover, William A; Russell, Denny; Reisdorf, Erik; Whyte, Thomas; Whitaker, Brett; Hatcher, Cynthia; Srinivasan, Velusamy; Tatti, Kathleen; Tondella, Maria Lucia; Wang, Xin; Winchell, Jonas M; Mayer, Leonard W; Jernigan, Daniel; Mawle, Alison C

    2016-02-01

    In this study, a multicenter evaluation of the Life Technologies TaqMan(®) Array Card (TAC) with 21 custom viral and bacterial respiratory assays was performed on the Applied Biosystems ViiA™ 7 Real-Time PCR System. The goal of the study was to demonstrate the analytical performance of this platform when compared to identical individual pathogen specific laboratory developed tests (LDTs) designed at the Centers for Disease Control and Prevention (CDC), equivalent LDTs provided by state public health laboratories, or to three different commercial multi-respiratory panels. CDC and Association of Public Health Laboratories (APHL) LDTs had similar analytical sensitivities for viral pathogens, while several of the bacterial pathogen APHL LDTs demonstrated sensitivities one log higher than the corresponding CDC LDT. When compared to CDC LDTs, TAC assays were generally one to two logs less sensitive depending on the site performing the analysis. Finally, TAC assays were generally more sensitive than their counterparts in three different commercial multi-respiratory panels. TAC technology allows users to spot customized assays and design TAC layout, simplify assay setup, conserve specimen, dramatically reduce contamination potential, and as demonstrated in this study, analyze multiple samples in parallel with good reproducibility between instruments and operators. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Development of a broadly reactive nested reverse transcription-PCR assay to detect murine noroviruses, and investigation of the prevalence of murine noroviruses in laboratory mice in Japan.

    PubMed

    Kitajima, Masaaki; Oka, Tomoichiro; Tohya, Yukinobu; Katayama, Hiroyuki; Takeda, Naokazu; Katayama, Kazuhiko

    2009-09-01

    A broadly reactive nested RT-PCR assay to detect MNV was developed and subsequently used to investigate the prevalence of MNV in laboratory mice in Japan. MNV were detected in 8 (22%) of 37 murine stool specimens by second-round PCR, although no positive band was obtained from any specimen by first-round PCR. Genetic analysis of the second round PCR products showed that MNV sequences detected in this study were closely matched (97.2 approximately 99.1%) to that of MNV-3 (DQ223042). This is the first report demonstrating the prevalence of MNV in Japan.

  14. A laser profilometry technique for monitoring fluvial dike breaching in laboratory experiments

    NASA Astrophysics Data System (ADS)

    Dewals, Benjamin; Rifai, Ismail; Erpicum, Sébastien; Archambeau, Pierre; Violeau, Damien; Pirotton, Michel; El kadi Abderrezzak, Kamal

    2017-04-01

    A challenging aspect for experimental modelling of fluvial dike breaching is the continuous monitoring of the transient breach geometry. In dam breaching cases induced by flow overtopping over the whole breach crest (plane erosion), a side view through a glass wall is sufficient to monitor the breach formation. This approach can be extended for 3D dam breach tests (spatial erosion) if the glass wall is located along the breach centreline. In contrast, using a side view does not apply for monitoring fluvial dike breaching, because the breach is not symmetric in this case. We present a non-intrusive, high resolution technique to record the breach development in experimental models of fluvial dikes by means of a laser profilometry (Rifai et al. 2016). Most methods used for monitoring dam and dike breaching involve the projection of a pattern (fringes, grid) on the dam or dike body and the analysis of its deformation on images recorded during the breaching (e.g., Pickert et al. 2011, Frank and Hager 2014). A major limitation of these methods stems from reflection on the water surface, particularly in the vicinity of the breach where the free surface is irregular and rippled. This issue was addressed by Spinewine et al. (2004), who used a single laser sheet so that reflections on the water surface were strongly limited and did not hamper the accurate processing of each image. We have developed a similar laser profilometry technique tailored for laboratory experiments on fluvial dike breaching. The setup is simple and relatively low cost. It consists of a digital video camera (resolution of 1920 × 1080 pixels at 60 frames per second) and a swiping red diode 30 mW laser that enables the projection of a laser sheet over the dike body. The 2D image coordinates of each deformed laser profile incident on the dike are transformed into 3D object coordinates using the Direct Linear Transformation (DLT) algorithm. All 3D object coordinates computed over a swiping cycle of the

  15. A European multicientre study on the comparison of HBV viral loads between VERIS HBV assay and Roche COBAS® TAQMAN® HBV test, Abbott RealTime HBV assay, Siemens VERSANT HBV assay, and Qiagen artus HBV RG kit.

    PubMed

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Izopet, Jacques; Lombardi, Alessandra; Marcos, MaAngeles; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel

    2017-10-01

    Hepatitis B viral load testing is essential to treatment and monitoring decisions in patients with chronic Hepatitis B. Beckman Coulter has developed the VERIS HBV Assay (Veris) for use on the fully automated DxN VERIS Molecular Diagnostics System. 1 OBJECTIVES: To evaluate the clinical performance of the Veris HBV Assay at multiple EU laboratories STUDY DESIGN: Method comparison was performed with a total of 344 plasma specimens from HBV infected patients tested with Veris and COBAS ® TaqMan ® HBV Test (Cobas), 207 specimens tested with Veris and RealTime HBV Assay (RealTime), 86 specimens tested with Veris and VERSANT ® HBV Assay (Versant), and 74 specimens tested with Veris and artus ® HBV RG PCR kit (artus). Bland-Altman analysis showed average bias of -0.46 log 10 IU/mL between Veris and Cobas, -0.46 log 10 IU/mL between Veris and RealTime, -0.36 log 10 IU/mL between Veris and Versant, and -0.12 log 10 IU/mL between Veris and artus. Bias was consistent across the assay range. Patient monitoring results using Veris demonstrated similar viral load trends over time to Cobas, RealTime, and artus. The VERIS HBV Assay demonstrated comparable clinical performance, with varying degrees of negative bias, compared to other currently marketed assays for HBV DNA monitoring. This negative bias should be taken into consideration if switching monitoring methods to Veris. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Laboratory preparedness in EU/EEA countries for detection of novel avian influenza A(H7N9) virus, May 2013

    PubMed Central

    Broberg, E; Pereyaslov, D; Struelens, M; Palm, D; Meijer, A; Ellis, J; Zambon, M; McCauley, J; Daniels, R

    2015-01-01

    Following human infections with novel avian influenza A(H7N9) viruses in China, the European Centre for Disease Prevention and Control, the World Health Organization (WHO) Regional Office for Europe and the European Reference Laboratory Network for Human Influenza (ERLI-Net) rapidly posted relevant information, including real-time RT-PCR protocols. An influenza RNA sequence-based computational assessment of detection capabilities for this virus was conducted in 32 national influenza reference laboratories in 29 countries, mostly WHO National Influenza Centres participating in the WHO Global Influenza Surveillance and Response System (GISRS). Twenty-seven countries considered their generic influenza A virus detection assay to be appropriate for the novel A(H7N9) viruses. Twenty-two countries reported having containment facilities suitable for its isolation and propagation. Laboratories in 27 countries had applied specific H7 real-time RT-PCR assays and 20 countries had N9 assays in place. Positive control virus RNA was provided by the WHO Collaborating Centre in London to 34 laboratories in 22 countries to allow evaluation of their assays. Performance of the generic influenza A virus detection and H7 and N9 subtyping assays was good in 24 laboratories in 19 countries. The survey showed that ERLI-Net laboratories had rapidly developed and verified good capability to detect the novel A(H7N9) influenza viruses. PMID:24507469

  17. Laboratory investigation of hypercoagulability.

    PubMed

    Francis, J L

    1998-01-01

    For many years, the laboratory investigation of patients with thrombophilia has lagged behind that of patients with bleeding diathesis. Improved understanding of the mechanisms that control and regulate coagulation, and the resultant recognition of new defects, have greatly stimulated clinical laboratory interest in this area. Assays to detect resistance to activated protein C; deficiencies of antithrombin, protein C, and protein S; and the presence of antiphospholipid antibodies are widely available and should form part of the investigation of patients that present with idiopathic thrombosis. Such a work-up will likely provide an explanation for thrombosis in 40 to 60% of patients. Abnormalities of fibrinogen and fibrinolysis may explain still more, although such defects are currently considered rare. In addition, presently unrecognized defects almost certainly exist, and the identification of such individuals will undoubtedly improve our understanding of the hemostatic mechanism. Laboratory tests to define the hypercoagulable state are continually being developed. They include whole blood coagulation and platelet function tests and novel activation markers. However, acceptance of these approaches by clinical laboratories has been slow.

  18. Targeted proteomic assays for quantitation of proteins identified by proteogenomic analysis of ovarian cancer

    DOE PAGES

    Song, Ehwang; Gao, Yuqian; Wu, Chaochao; ...

    2017-07-19

    Here, mass spectrometry (MS) based targeted proteomic methods such as selected reaction monitoring (SRM) are becoming the method of choice for preclinical verification of candidate protein biomarkers. The Clinical Proteomic Tumor Analysis Consortium (CPTAC) of the National Cancer Institute has investigated the standardization and analytical validation of the SRM assays and demonstrated robust analytical performance on different instruments across different laboratories. An Assay Portal has also been established by CPTAC to provide the research community a resource consisting of large set of targeted MS-based assays, and a depository to share assays publicly, providing that assays meet the guidelines proposed bymore » CPTAC. Herein, we report 98 SRM assays covering 70 candidate protein biomarkers previously reported as associated with ovarian cancer that have been thoroughly characterized according to the CPTAC Assay Characterization Guidance Document. The experiments, methods and results for characterizing these SRM assays for their MS response, repeatability, selectivity, stability, and reproducible detection of endogenous analytes are described in detail.« less

  19. 40 CFR 141.705 - Approved laboratories.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Cryptosporidium analysis by an equivalent State laboratory certification program. (b) E. coli. Any laboratory... coliform or fecal coliform analysis under § 141.74 is approved for E. coli analysis under this subpart when the laboratory uses the same technique for E. coli that the laboratory uses for § 141.74. (c...

  20. 40 CFR 141.705 - Approved laboratories.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Cryptosporidium analysis by an equivalent State laboratory certification program. (b) E. coli. Any laboratory... coliform or fecal coliform analysis under § 141.74 is approved for E. coli analysis under this subpart when the laboratory uses the same technique for E. coli that the laboratory uses for § 141.74. (c...

  1. 40 CFR 141.705 - Approved laboratories.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Cryptosporidium analysis by an equivalent State laboratory certification program. (b) E. coli. Any laboratory... coliform or fecal coliform analysis under § 141.74 is approved for E. coli analysis under this subpart when the laboratory uses the same technique for E. coli that the laboratory uses for § 141.74. (c...

  2. 40 CFR 141.705 - Approved laboratories.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Cryptosporidium analysis by an equivalent State laboratory certification program. (b) E. coli. Any laboratory... coliform or fecal coliform analysis under § 141.74 is approved for E. coli analysis under this subpart when the laboratory uses the same technique for E. coli that the laboratory uses for § 141.74. (c...

  3. 40 CFR 141.705 - Approved laboratories.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Cryptosporidium analysis by an equivalent State laboratory certification program. (b) E. coli. Any laboratory... coliform or fecal coliform analysis under § 141.74 is approved for E. coli analysis under this subpart when the laboratory uses the same technique for E. coli that the laboratory uses for § 141.74. (c...

  4. The analytical validation of the Oncotype DX Recurrence Score assay

    PubMed Central

    Baehner, Frederick L

    2016-01-01

    In vitro diagnostic multivariate index assays are highly complex molecular assays that can provide clinically actionable information regarding the underlying tumour biology and facilitate personalised treatment. These assays are only useful in clinical practice if all of the following are established: analytical validation (i.e., how accurately/reliably the assay measures the molecular characteristics), clinical validation (i.e., how consistently/accurately the test detects/predicts the outcomes of interest), and clinical utility (i.e., how likely the test is to significantly improve patient outcomes). In considering the use of these assays, clinicians often focus primarily on the clinical validity/utility; however, the analytical validity of an assay (e.g., its accuracy, reproducibility, and standardisation) should also be evaluated and carefully considered. This review focuses on the rigorous analytical validation and performance of the Oncotype DX® Breast Cancer Assay, which is performed at the Central Clinical Reference Laboratory of Genomic Health, Inc. The assay process includes tumour tissue enrichment (if needed), RNA extraction, gene expression quantitation (using a gene panel consisting of 16 cancer genes plus 5 reference genes and quantitative real-time RT-PCR), and an automated computer algorithm to produce a Recurrence Score® result (scale: 0–100). This review presents evidence showing that the Recurrence Score result reported for each patient falls within a tight clinically relevant confidence interval. Specifically, the review discusses how the development of the assay was designed to optimise assay performance, presents data supporting its analytical validity, and describes the quality control and assurance programmes that ensure optimal test performance over time. PMID:27729940

  5. The analytical validation of the Oncotype DX Recurrence Score assay.

    PubMed

    Baehner, Frederick L

    2016-01-01

    In vitro diagnostic multivariate index assays are highly complex molecular assays that can provide clinically actionable information regarding the underlying tumour biology and facilitate personalised treatment. These assays are only useful in clinical practice if all of the following are established: analytical validation (i.e., how accurately/reliably the assay measures the molecular characteristics), clinical validation (i.e., how consistently/accurately the test detects/predicts the outcomes of interest), and clinical utility (i.e., how likely the test is to significantly improve patient outcomes). In considering the use of these assays, clinicians often focus primarily on the clinical validity/utility; however, the analytical validity of an assay (e.g., its accuracy, reproducibility, and standardisation) should also be evaluated and carefully considered. This review focuses on the rigorous analytical validation and performance of the Oncotype DX ® Breast Cancer Assay, which is performed at the Central Clinical Reference Laboratory of Genomic Health, Inc. The assay process includes tumour tissue enrichment (if needed), RNA extraction, gene expression quantitation (using a gene panel consisting of 16 cancer genes plus 5 reference genes and quantitative real-time RT-PCR), and an automated computer algorithm to produce a Recurrence Score ® result (scale: 0-100). This review presents evidence showing that the Recurrence Score result reported for each patient falls within a tight clinically relevant confidence interval. Specifically, the review discusses how the development of the assay was designed to optimise assay performance, presents data supporting its analytical validity, and describes the quality control and assurance programmes that ensure optimal test performance over time.

  6. Suitability of a liquid chromatography assay of neomycin sulfate to replace the microbiological assay for neomycin in USP Monographs.

    PubMed

    Hanko, Valoran P; Rohrer, Jeffrey S

    2010-01-05

    The current USP National Formulary contains 65 Monographs for drug formulations containing neomycin. All 65 Monographs prescribe a bioassay for neomycin assay. This bioassay, based on cell culture, is labor intensive, has poor precision, and cannot be adapted for purity or identification. High-performance anion-exchange chromatography with integrated pulsed amperometric detection (HPAE-IPAD), a liquid chromatography technique, has been shown to be suitable for neomycin purity analysis and neomycin assay of an over-the-counter first aid cream (Hanko and Rohrer [17]). Here we propose that an HPAE-IPAD assay can replace the bioassay in the 65 neomycin-containing Monographs. We applied the HPAE-IPAD assay to four neomycin-containing drug products representing the four classes of formulations found in the 65 Monographs, liquid, solid, suspension, and cream. Each drug was analyzed with two chromatography systems, and on 3 separate days. For all products, HPAE-IPAD measurements were precise and accurate with respect to the label concentrations. There was also high accuracy for spike recovery of neomycin from the four drug products throughout 70-150% of the labeled concentration. These results suggest that an HPAE-IPAD assay would be an accurate assay for neomycin, and would be faster and more precise than the current bioassay.

  7. Annotation of Sequence Variants in Cancer Samples: Processes and Pitfalls for Routine Assays in the Clinical Laboratory.

    PubMed

    Lee, Lobin A; Arvai, Kevin J; Jones, Dan

    2015-07-01

    As DNA sequencing of multigene panels becomes routine for cancer samples in the clinical laboratory, an efficient process for classifying variants has become more critical. Determining which germline variants are significant for cancer disposition and which somatic mutations are integral to cancer development or therapy response remains difficult, even for well-studied genes such as BRCA1 and TP53. We compare and contrast the general principles and lines of evidence commonly used to distinguish the significance of cancer-associated germline and somatic genetic variants. The factors important in each step of the analysis pipeline are reviewed, as are some of the publicly available annotation tools. Given the range of indications and uses of cancer sequencing assays, including diagnosis, staging, prognostication, theranostics, and residual disease detection, the need for flexible methods for scoring of variants is discussed. The usefulness of protein prediction tools and multimodal risk-based or Bayesian approaches are highlighted. Using TET2 variants encountered in hematologic neoplasms, several examples of this multifactorial approach to classifying sequence variants of unknown significance are presented. Although there are still significant gaps in the publicly available data for many cancer genes that limit the broad application of explicit algorithms for variant scoring, the elements of a more rigorous model are outlined. Copyright © 2015 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  8. Performance Assessment of Human and Cattle Associated Quantitative Real-time PCR Assays - slides

    EPA Science Inventory

    The presentation overview is (1) Single laboratory performance assessment of human- and cattle associated PCR assays and (2) A Field Study: Evaluation of two human fecal waste management practices in Ohio watershed.

  9. Application of a multiplex PCR assay for Campylobacter fetus detection and subspecies differentiation in uncultured samples of aborted bovine fetuses.

    PubMed

    Iraola, Gregorio; Hernández, Martín; Calleros, Lucía; Paolicchi, Fernando; Silveyra, Silvia; Velilla, Alejandra; Carretto, Luis; Rodríguez, Eliana; Pérez, Ruben

    2012-12-01

    Campylobacter (C.) fetus (epsilonproteobacteria) is an important veterinary pathogen. This species is currently divided into C. fetus subspecies (subsp.) fetus (Cff) and C. fetus subsp. venerealis (Cfv). Cfv is the causative agent of bovine genital Campylobacteriosis, an infectious disease that leads to severe reproductive problems in cattle worldwide. Cff is a more general pathogen that causes reproductive problems mainly in sheep although cattle can also be affected. Here we describe a multiplex PCR method to detect C. fetus and differentiate between subspecies in a single step. The assay was standardized using cultured strains and successfully used to analyze the abomasal liquid of aborted bovine fetuses without any pre-enrichment step. Results of our assay were completely consistent with those of traditional bacteriological diagnostic methods. Furthermore, the multiplex PCR technique we developed may be easily adopted by any molecular diagnostic laboratory as a complementary tool for detecting C. fetus subspecies and obtaining epidemiological information about abortion events in cattle.

  10. Rapid mycobacteria drug susceptibility testing using Gel Microdrop (GMD) Growth Assay and flow cytometry.

    PubMed

    Akselband, Y; Cabral, C; Shapiro, D S; McGrath, P

    2005-08-01

    Control of multi-drug-resistant tuberculosis has been hampered by the lack of simple, rapid and sensitive methods for assessing bacterial growth and antimicrobial susceptibility. Due to the increasing incidence and high frequency of mutations, it is unlikely that culture methods will disappear in the foreseeable future. Therefore, the need to modernize methods for rapid detection of viable clinical isolates, at a minimum as a gold standard, will persist. Previously, we confirmed the feasibility of using the Gel Microdrop (GMD) Growth Assay for identifying sub-populations of resistant Mycobacteria by testing different laboratory strains. Briefly, this assay format relies on encapsulating single bacterium in agarose microspheres and identifying clonogenic growth using flow cytometry and fluorescent staining. In this study, we modified the GMD Growth Assay to make it suitable for clinical applications. We demonstrated the effectiveness and safety of this novel approach for detecting drug susceptibility in clinically relevant laboratory strains as well as clinical isolates of Mycobacterium tuberculosis. Correlation between results using the GMD Growth Assay format and results using two well characterized methods (Broth Microdilution MIC and BACTEC 460TB) was 87.5% and 90%, respectively. However, due to the inherent sensitivity of flow cytometry and the ability to detect small (<1%) sub-populations of resistant mycobacteria, the GMD Growth Assay identified more cases of drug resistance. Using 4 clinically relevant mycobacterial strains, we assessed susceptibility to primary anti-tuberculosis drugs using both the Broth Microdilution MIC method and the GMD Growth Assay. We performed 24 tests on isoniazid-resistant BCG, Mycobacterium tuberculosis H37Ra and Mycobacterium avium strains. The Broth Microdilution MIC method identified 7 cases (29.1%) of resistance to INH and EMB compared to the GMD Growth Assay which identified resistance in 10 cases (41.6%); in 3 cases (12

  11. Analytical performances of a new enzymatic assay for hemoglobin A1c.

    PubMed

    Jaisson, Stéphane; Desmons, Aurore; Renard, Benoît; Chevelle, Benjamin; Leroy, Nathalie; Gillery, Philippe

    2014-07-01

    HbA1c is considered the gold standard for the follow-up of diabetic patients and a new diagnostic tool for diabetes mellitus, which implies the availability of reliable assay methods. We have evaluated a new assay developed by Abbott Laboratories, based on the enzymatic quantification of HbA1c by a fructosyl dipeptide oxidase using Architect analyzers. Precision, linearity, correlation with a HPLC method, accuracy and potential impact interferences on HbA1c measurement have been evaluated. Intra-day and between-day CVs were lower than 1.2% and linearity was excellent from 19 mmol/mol (3.9%) to 163 mmol/mol (17.1%). The results were well correlated with those obtained by the HPLC (Variant II device, kit NU - BioRad): HbA1c [Architect, mmol/mol]=0.986×HbA1c [Variant II, mmol/mol]+0.713 (r=0.998, n=109). This method provided consistent results with IFCC titrated quality control samples. Classical interferences in HbA1c assays (i.e. labile HbA1c, carbamylated hemoglobin, triglycerides or bilirubin) did not have an impact on HbA1c quantification by this method. This new enzymatic assay proved to be a robust and reliable method for HbA1c measurement suitable for routine practice in clinical chemistry laboratories. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Clinical Evaluation of Fully Automated Elecsys® Syphilis Assay for the Detection of Antibodies of Treponema pallidum.

    PubMed

    Li, Dongdong; An, Jingna; Wang, Tingting; Tao, Chuanmin; Wang, Lanlan

    2016-11-01

    The resurgence of syphilis in recent years has become a serious threat to the public health worldwide, and the serological detection of specific antibodies against Treponema pallidum (TP) remains the most reliable method for laboratory diagnosis of syphilis. The performance of the Elecsys ® Syphilis assay, a brand new electrochemiluminescene immunoassay (ECLIA), was assessed by large amounts of samples in this study. In comparison with InTec assay, the Elecsys ® Syphilis assay was evaluated in 146 preselected samples from patients with syphilis, 1803 clinical routine samples, and 175 preselected samples from specific populations with reportedly increased rates of false-positive syphilis test results. Discrepancy samples must be investigated by Mikrogen Syphilis recomline assay. There was an overall agreement of 99.58% between two assays (Kappa = 0.975). The sensitivity and specificity of the Elecsys ® Syphilis assay were 100.0% (95% CI, 96.8-100.0%) and 99.8% (95% CI, 99.5-100.0%), respectively. The Elecsys syphilis assay displays better sensitivity (100%), specificity (99.8%), PPV (98.7%), and NPV (100%) in 2124 samples enrolled, compared with the InTec assay. Considering the excellent ease of use and automation, high throughput, and its superior sensitivity, especially in primary syphilis, the Elecsys ® Syphilis assay could represent an outstanding choice for screening of syphilis in high-volume laboratories. However, more attention was still needed, or the results must be confirmed by other treponemal immunoassays. The new Elecsys ® Syphilis assay is applied to patients with malignant neoplasm or HIV infection. © 2016 Wiley Periodicals, Inc.

  13. Optical assays based on colloidal inorganic nanoparticles.

    PubMed

    Ghasemi, Amir; Rabiee, Navid; Ahmadi, Sepideh; Hashemzadeh, Shabnam; Lolasi, Farshad; Bozorgomid, Mahnaz; Kalbasi, Alireza; Nasseri, Behzad; Shiralizadeh Dezfuli, Amin; Aref, Amir Reza; Karimi, Mahdi; Hamblin, Michael R

    2018-06-20

    Colloidal inorganic nanoparticles have wide applications in the detection of analytes and in biological assays. A large number of these assays rely on the ability of gold nanoparticles (AuNPs, in the 20 nm diameter size range) to undergo a color change from red to blue upon aggregation. AuNP assays can be based on cross-linking, non-cross linking or unmodified charge-based aggregation. Nucleic acid-based probes, monoclonal antibodies, and molecular-affinity agents can be attached by covalent or non-covalent means. Surface plasmon resonance and SERS techniques can be utilized. Silver NPs also have attractive optical properties (higher extinction coefficient). Combinations of AuNPs and AgNPs in nanocomposites can have additional advantages. Magnetic NPs and ZnO, TiO2 and ZnS as well as insulator NPs including SiO2 can be employed in colorimetric assays, and some can act as peroxidase mimics in catalytic applications. This review covers the synthesis and stabilization of inorganic NPs and their diverse applications in colorimetric and optical assays for analytes related to environmental contamination (metal ions and pesticides), and for early diagnosis and monitoring of diseases, using medically important biomarkers.

  14. A Western blot-based investigation of the yeast secretory pathway designed for an intermediate-level undergraduate cell biology laboratory.

    PubMed

    Hood-Degrenier, Jennifer K

    2008-01-01

    The movement of newly synthesized proteins through the endomembrane system of eukaryotic cells, often referred to generally as the secretory pathway, is a topic covered in most intermediate-level undergraduate cell biology courses. An article previously published in this journal described a laboratory exercise in which yeast mutants defective in two distinct steps of protein secretion were differentiated using a genetic reporter designed specifically to identify defects in the first step of the pathway, the insertion of proteins into the endoplasmic reticulum (Vallen, 2002). We have developed two versions of a Western blotting assay that serves as a second way of distinguishing the two secretory mutants, which we pair with the genetic assay in a 3-wk laboratory module. A quiz administered before and after students participated in the lab activities revealed significant postlab gains in their understanding of the secretory pathway and experimental techniques used to study it. A second survey administered at the end of the lab module assessed student perceptions of the efficacy of the lab activities; the results of this survey indicated that the experiments were successful in meeting a set of educational goals defined by the instructor.

  15. Nonisotopic detection of human papillomavirus DNA in clinical specimens using a consensus PCR and a generic probe mix in an enzyme-linked immunosorbent assay format.

    PubMed

    Kornegay, J R; Shepard, A P; Hankins, C; Franco, E; Lapointe, N; Richardson, H; Coutleé, F

    2001-10-01

    We assessed the value of a new digoxigenin (DIG)-labeled generic probe mix in a PCR-enzyme-linked immunosorbent assay format to screen for the presence of human papillomavirus (HPV) DNA amplified from clinical specimens. After screening with this new generic assay is performed, HPV DNA-positive samples can be directly genotyped using a reverse blotting method with product from the same PCR amplification. DNA from 287 genital specimens was amplified via PCR using biotin-labeled consensus primers directed to the L1 gene. HPV amplicons were captured on a streptavidin-coated microwell plate (MWP) and detected with a DIG-labeled HPV generic probe mix consisting of nested L1 fragments from types 11, 16, 18, and 51. Coamplification and detection of human DNA with biotinylated beta-globin primers served as a control for both sample adequacy and PCR amplification. All specimens were genotyped using a reverse line blot assay (13). Results for the generic assay using MWPs and a DIG-labeled HPV generic probe mix (DIG-MWP generic probe assay) were compared with results from a previous analysis using dot blots with a radiolabeled nested generic probe mix and type-specific probes for genotyping. The DIG-MWP generic probe assay resulted in high intralaboratory concordance in genotyping results (88% versus 73% agreement using traditional methods). There were 207 HPV-positive results using the DIG-MWP method and 196 positives using the radiolabeled generic probe technique, suggesting slightly improved sensitivity. Only one sample failed to test positive with the DIG-MWP generic probe assay in spite of a positive genotyping result. Concordance between the two laboratories was nearly 87%. Approximately 6% of samples that were positive or borderline when tested with the DIG-MWP generic probe assay were not detected with the HPV type-specific panel, perhaps representing very rare or novel HPV types. This new method is easier to perform than traditional generic probe techniques and uses

  16. Development and validation of sensitive real-time RT-PCR assay for broad detection of rabies virus.

    PubMed

    Faye, Martin; Dacheux, Laurent; Weidmann, Manfred; Diop, Sylvie Audrey; Loucoubar, Cheikh; Bourhy, Hervé; Sall, Amadou Alpha; Faye, Ousmane

    2017-05-01

    Rabies virus (RABV) remains one of the most important global zoonotic pathogens. RABV causes rabies, an acute encephalomyelitis associated with a high rate of mortality in humans and animals and affecting different parts of the world, particularly in Asia and Africa. Confirmation of rabies diagnosis relies on laboratory diagnosis, in which molecular techniques such as detection of viral RNA by reverse transcription polymerase chain reaction (RT-PCR) are increasingly being used. In this study, two real-time quantitative RT-PCR assays were developed for large-spectrum detection of RABV, with a focus on African isolates. The primer and probe sets were targeted highly conserved regions of the nucleoprotein (N) and polymerase (L) genes. The results indicated the absence of non-specific amplification and cross-reaction with a range of other viruses belonging to the same taxonomic family, i.e. Rhabdoviridae, as well as negative brain tissues from various host species. Analytical sensitivity ranged between 100 to 10 standard RNA copies detected per reaction for N-gene and L-gene assays, respectively. Effective detection and high sensitivity of these assays on African isolates showed that they can be successfully applied in general research and used in diagnostic process and epizootic surveillance in Africa using a double-check strategy. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Rapid identification of tomato Sw-5 resistance-breaking isolates of Tomato spotted wilt virus using high resolution melting and TaqMan SNP Genotyping assays as allelic discrimination techniques.

    PubMed

    di Rienzo, Valentina; Bubici, Giovanni; Montemurro, Cinzia; Cillo, Fabrizio

    2018-01-01

    In tomato, resistance to Tomato spotted wilt virus (TSWV) is conferred by the dominant gene, designated Sw-5. Virulent Sw-5 resistance breaking (SRB) mutants of TSWV have been reported on Sw-5 tomato cultivars. Two different PCR-based allelic discrimination techniques, namely Custom TaqMan™ SNP Genotyping and high-resolution melting (HRM) assays, were developed and compared for their ability to distinguish between avirulent (Sw-5 non-infecting, SNI) and SRB biotypes. TaqMan assays proved to be more sensitive (threshold of detection in a range of 50-70 TSWV RNA copies) and more reliable than HRM, assigning 25 TSWV isolates to their correct genotype with an accuracy of 100%. Moreover, the TaqMan SNP assays were further improved developing a rapid and simple protocol that included crude leaf extraction for RNA template preparations. On the other hand, HRM assays showed higher levels of sensitivity than TaqMan when used to co-detect both biotypes in different artificial mixtures. These diagnostic assays contributed to gain preliminary information on the epidemiology of TSWV isolates in open field conditions. In fact, the presented data suggest that SRB isolates are present as stable populations established year round, persisting on both winter (globe artichoke) and summer (tomato) crops, in the same cultivated areas of Southern Italy.

  18. Variability of creatinine measurements in clinical laboratories: results from the CRIC study.

    PubMed

    Joffe, Marshall; Hsu, Chi-yuan; Feldman, Harold I; Weir, Matthew; Landis, J R; Hamm, L Lee

    2010-01-01

    Estimating equations using serum creatinine (SCr) are often used to assess glomerular filtration rate (GFR). Such creatinine (Cr)-based formulae may produce biased estimates of GFR when using Cr measurements that have not been calibrated to reference laboratories. In this paper, we sought to examine the degree of this variation in Cr assays in several laboratories associated with academic medical centers affiliated with the Chronic Renal Insufficiency Cohort (CRIC) Study; to consider how best to correct for this variation, and to quantify the impact of such corrections on eligibility for participation in CRIC. Variability of Cr is of particular concern in the conduct of CRIC, a large multicenter study of subjects with chronic renal disease, because eligibility for the study depends on Cr-based assessment of GFR. A library of 5 large volume plasma specimens from apheresis patients was assembled, representing levels of plasma Cr from 0.8 to 2.4 mg/dl. Samples from this library were used for measurement of Cr at each of the 14 CRIC laboratories repetitively over time. We used graphical displays and linear regression methods to examine the variability in Cr, and used linear regression to develop calibration equations. We also examined the impact of the various calibration equations on the proportion of subjects screened as potential participants who were actually eligible for the study. There was substantial variability in Cr assays across laboratories and over time. We developed calibration equations for each laboratory; these equations varied substantially among laboratories and somewhat over time in some laboratories. The laboratory site contributed the most to variability (51% of the variance unexplained by the specimen) and variation with time accounted for another 15%. In some laboratories, calibration equations resulted in differences in eligibility for CRIC of as much as 20%. The substantial variability in SCr assays across laboratories necessitates calibration

  19. A Fully Automated High-Throughput Zebrafish Behavioral Ototoxicity Assay.

    PubMed

    Todd, Douglas W; Philip, Rohit C; Niihori, Maki; Ringle, Ryan A; Coyle, Kelsey R; Zehri, Sobia F; Zabala, Leanne; Mudery, Jordan A; Francis, Ross H; Rodriguez, Jeffrey J; Jacob, Abraham

    2017-08-01

    Zebrafish animal models lend themselves to behavioral assays that can facilitate rapid screening of ototoxic, otoprotective, and otoregenerative drugs. Structurally similar to human inner ear hair cells, the mechanosensory hair cells on their lateral line allow the zebrafish to sense water flow and orient head-to-current in a behavior called rheotaxis. This rheotaxis behavior deteriorates in a dose-dependent manner with increased exposure to the ototoxin cisplatin, thereby establishing itself as an excellent biomarker for anatomic damage to lateral line hair cells. Building on work by our group and others, we have built a new, fully automated high-throughput behavioral assay system that uses automated image analysis techniques to quantify rheotaxis behavior. This novel system consists of a custom-designed swimming apparatus and imaging system consisting of network-controlled Raspberry Pi microcomputers capturing infrared video. Automated analysis techniques detect individual zebrafish, compute their orientation, and quantify the rheotaxis behavior of a zebrafish test population, producing a powerful, high-throughput behavioral assay. Using our fully automated biological assay to test a standardized ototoxic dose of cisplatin against varying doses of compounds that protect or regenerate hair cells may facilitate rapid translation of candidate drugs into preclinical mammalian models of hearing loss.

  20. Different Approaches for Assaying Melanosome Transfer

    PubMed Central

    Berens, Werner; Van Den Bossche, Karolien; Yoon, Tae-Jin; Westbroek, Wendy; Valencia, Julio C.; Out, Coby J.; Naeyaert, Jean Marie; Hearing, Vincent J.; Lambert, Jo

    2006-01-01

    Summary Many approaches have been tried to establish assays for melanosome transfer to keratinocytes. In this report we describe and summarize various novel attempts to label melanosomes in search of a reliable, specific, reproducible and quantitative assay system. We tried to fluorescently label melanosomes by transfection of GFP-labeled melanosomal proteins and by incubation of melanocytes with fluorescent melanin intermediates or homologues. In most cases a weak cytoplasmic fluorescence was perceived, which was probably due to incorrect sorting or deficient incorporation of the fluorescent protein and different localisation. We were able to label melanosomes via incorporation of 14C-thiouracil into melanin. Consequently, we tried to develop an assay to separate keratinocytes with transferred radioactivity from melanocytes after co-culture. Differential trypsination and different magnetic bead separation techniques were tested with unsatisfactory results. An attempt was also made to incorporate fluorescent thiouracil, since this would allow cells to be separated by FACS. In conclusion, different methods to measure pigment transfer between donor melanocytes and acceptor keratinocytes were thoroughly examined. This information could give other researchers a head start in the search for a melanosome transfer assay with said qualities to better understand pigment transfer. PMID:16162177

  1. Implementation and Challenges of Direct Acoustic Dosing into Cell-Based Assays.

    PubMed

    Roberts, Karen; Callis, Rowena; Ikeda, Tim; Paunovic, Amalia; Simpson, Carly; Tang, Eric; Turton, Nick; Walker, Graeme

    2016-02-01

    Since the adoption of Labcyte Echo Acoustic Droplet Ejection (ADE) technology by AstraZeneca in 2005, ADE has become the preferred method for compound dosing into both biochemical and cell-based assays across AstraZeneca research and development globally. The initial implementation of Echos and the direct dosing workflow provided AstraZeneca with a unique set of challenges. In this article, we outline how direct Echo dosing has evolved over the past decade in AstraZeneca. We describe the practical challenges of applying ADE technology to 96-well, 384-well, and 1536-well assays and how AstraZeneca developed and applied software and robotic solutions to generate fully automated and effective cell-based assay workflows. © 2015 Society for Laboratory Automation and Screening.

  2. DNA Methyltransferase Activity Assays: Advances and Challenges

    PubMed Central

    Poh, Wan Jun; Wee, Cayden Pang Pee; Gao, Zhiqiang

    2016-01-01

    DNA methyltransferases (MTases), a family of enzymes that catalyse the methylation of DNA, have a profound effect on gene regulation. A large body of evidence has indicated that DNA MTase is potentially a predictive biomarker closely associated with genetic disorders and genetic diseases like cancer. Given the attention bestowed onto DNA MTases in molecular biology and medicine, highly sensitive detection of DNA MTase activity is essential in determining gene regulation, epigenetic modification, clinical diagnosis and therapeutics. Conventional techniques such as isotope labelling are effective, but they often require laborious sample preparation, isotope labelling, sophisticated equipment and large amounts of DNA, rendering them unsuitable for uses at point-of-care. Simple, portable, highly sensitive and low-cost assays are urgently needed for DNA MTase activity screening. In most recent technological advances, many alternative DNA MTase activity assays such as fluorescent, electrochemical, colorimetric and chemiluminescent assays have been proposed. In addition, many of them are coupled with nanomaterials and/or enzymes to significantly enhance their sensitivity. Herein we review the progress in the development of DNA MTase activity assays with an emphasis on assay mechanism and performance with some discussion on challenges and perspectives. It is hoped that this article will provide a broad coverage of DNA MTase activity assays and their latest developments and open new perspectives toward the development of DNA MTase activity assays with much improved performance for uses in molecular biology and clinical practice. PMID:26909112

  3. Performance evaluation of a particle-enhanced turbidimetric cystatin C assay on the Abbott ci8200 analyzer.

    PubMed

    Flodin, Mats; Larsson, Anders

    2009-06-01

    Glomerular filtration rate (GFR) is widely accepted as the best overall measure of kidney function. Cystatin C is a novel endogenous GFR marker that has been shown to be superior to creatinine for estimation of GFR in several studies. There is a need for cystatin C assays adapted to routine chemistry instrument to minimize turnaround times and allowing 24 h/day availability. We have evaluated a new cystatin C assay developed for Architect cSystem (Abbott Laboratories, Abbott Park, IL, USA). The cystatin C assay showed good agreement with the corresponding assay from Dade Behring (Deerfield, IL, USA). The assay has a very low total imprecision and a good linearity. The new cystatin C assay is an interesting alternative to current cystatin C assays. On an Architect cSystem the assay can be performed with the same turnaround times and availability as creatinine.

  4. Microcoupon Assay Of Adhesion And Growth Of Bacterial Films

    NASA Technical Reports Server (NTRS)

    Pierson, Duane L.; Koenig, David W.

    1994-01-01

    Microbiological assay technique facilitates determination of some characteristics of sessile bacteria like those that attach to and coat interior walls of water-purification systems. Biofilms cause sickness and interfere with purification process. Technique enables direct measurement of rate of attachment of bacterial cells, their metabolism, and effects of chemicals on them. Used to quantify effects of both bactericides and growth-stimulating agents and in place of older standard plate-count and tube-dilution techniques.

  5. Gene encoding the group B streptococcal protein R4, its presence in clinical reference laboratory isolates & R4 protein pepsin sensitivity.

    PubMed

    Smith, B L; Flores, A; Dechaine, J; Krepela, J; Bergdall, A; Ferrieri, P

    2004-05-01

    R proteins were first identified by Lancefield in group B Streptococcus (GBS) as resistant to trypsin at pH8 and sensitive to pepsin at pH2. The R4 protein found predominantly in type III and some type II and V invasive isolates conforms to these criteria. The Rib protein, although structurally and epidemiologically similar to R4, was reported as resistant to both proteases. We report here the gene encoding the R4 protein from a type III group B streptococcal isolate (76-043) well characterized in our laboratory. Trypsin extracted GBS proteins were assayed for protease sensitivities by double-diffusion Ouchterlony using varying conditions for the enzyme pepsin. Standard haemoglobin assay was used to examine pepsin enzymatic activity. Thirty clinical isolates of varying protein profiles identified by double-diffusion from our reference strain laboratory were screened by PCR and Southern technique. SDS-PAGE gel purified R4 amino acid sequences were determined and used to design oligonucleotide primers for screening a 76-043 genomic library. R4 was sensitive to pepsin at pH2 but appeared resistant at pH4, the reported pH used for Rib. By standard haemoglobin assay and trypsin extract studies of R4 protein, pepsin was shown to be active at pH2, yet easily inactivated; assays of GBS surface proteins are critical at pH2. Of the amino acids initially sequenced from R4, 88 per cent (61/69) showed identity to Rib; the r4 nucleotide sequence was identical to that of rib. All isolates with strong positive protein reactions for R4 were positive in both PCR and Southern technique, whereas isolates expressing alpha, beta, R1/R4, and R5 (BPS) protein profiles were not. Sequenced PCR products aligned with identity to the R4 and Rib nucleotide sequences and confirmed the identity of these proteins and their molecular sequences.

  6. Signal processing techniques for the U.S. Army Research Laboratory stepped frequency ultra-wideband radar

    NASA Astrophysics Data System (ADS)

    Nguyen, Lam

    2017-05-01

    The U.S. Army Research Laboratory (ARL) recently designed and tested a new prototype radar, the Spectrally Agile Frequency-Incrementing Reconfigurable (SAFIRE) radar system, based on a stepped-frequency architecture to address issues associated with our previous impulse-based radars. This is a low-frequency ultra-wideband (UWB) radar with frequencies spanning from 300 to 2000 MHz. Mounted on a vehicle, the radar can be configured in either sidelooking or forward-looking synthetic aperture radar (SAR) mode. We recently conducted our first experiment at Yuma Proving Grounds (YPG). This paper summarizes the radar configurations, parameters, and SAR geometry. The radar data and other noise sources, to include the self-interference signals and radio-frequency interference (RFI) noise sources, are presented and characterized in both the raw (pre-focus) and SAR imagery domains. This paper also describes our signal processing techniques for extracting noise from radar data, as well as the SAR imaging algorithms for forming SAR imagery in both forward- and side-looking modes. Finally, this paper demonstrates our spectral recovery technique and results for a radar operating in a spectrally restricted environment.

  7. Comet assay: an essential tool in toxicological research.

    PubMed

    Glei, M; Schneider, T; Schlörmann, W

    2016-10-01

    The comet assay is a versatile, reliable, cost-efficient, and fast technique for detecting DNA damage and repair in any tissue. It is useable in almost any cell type and applicable to both eukaryotic and prokaryotic organisms. Instead of highlighting one of the numerous specific aspects of the comet assay, the present review aims at giving an overview about the evolution of this widely applicable method from the first description by Ostling and Johanson to the OECD Guideline 489 for the in vivo mammalian comet assay. In addition, methodical aspects and the influence of critical steps of the assay as well as the evaluation of results and improvements of the method are reviewed. Methodical aspects regarding oxidative DNA damage and repair are also addressed. An overview about the most recent works and relevant cutting-edge reviews based on the comet assay with special regard to, e.g., clinical applications, nanoparticles or environmental risk assessment concludes this review. Taken together, the presented overview raises expectations to further decades of successful applications and enhancements of this excellent method.

  8. Intralaboratory and interlaboratory evaluation of the EpiDerm 3D human reconstructed skin micronucleus (RSMN) assay.

    PubMed

    Hu, Ting; Kaluzhny, Yulia; Mun, Greg C; Barnett, Brenda; Karetsky, Viktor; Wilt, Nathan; Klausner, Mitchell; Curren, Rodger D; Aardema, Marilyn J

    2009-03-17

    A novel in vitro human reconstructed skin micronucleus (RSMN) assay has been developed using the EpiDerm 3D human skin model [R. D. Curren, G. C. Mun, D. P. Gibson, and M. J. Aardema, Development of a method for assessing micronucleus induction in a 3D human skin model EpiDerm, Mutat. Res. 607 (2006) 192-204]. The RSMN assay has potential use in genotoxicity assessments as a replacement for in vivo genotoxicity assays that will be banned starting in 2009 according to the EU 7th Amendment to the Cosmetics Directive. Utilizing EpiDerm tissues reconstructed with cells from four different donors, intralaboratory and interlaboratory reproducibility of the RSMN assay were examined. Seven chemicals were evaluated in three laboratories using a standard protocol. Each chemical was evaluated in at least two laboratories and in EpiDerm tissues from at least two different donors. Three model genotoxins, mitomycin C (MMC), vinblastine sulfate (VB) and methyl methanesulfonate (MMS) induced significant, dose-related increases in cytotoxicity and MN induction in EpiDerm tissues. Conversely, four dermal non-carcinogens, 4-nitrophenol (4-NP), trichloroethylene (TCE), 2-ethyl-1,3-hexanediol (EHD), and 1,2-epoxydodecane (EDD) were negative in the RSMN assay. Results between tissues reconstructed from different donors were comparable. These results indicate the RSMN assay using the EpiDerm 3D human skin model is a promising new in vitro genotoxicity assay that allows evaluation of chromosome damage following "in vivo-like" dermal exposures.

  9. Microbiologic assay of space hardware.

    NASA Technical Reports Server (NTRS)

    Favero, M. S.

    1971-01-01

    Review of the procedures used in the microbiological examination of space hardware. The general procedure for enumerating aerobic and anaerobic microorganisms and spores is outlined. Culture media and temperature-time cycles used for incubation are reviewed, along with assay systems designed for the enumeration of aerobic and anaerobic spores. The special problems which are discussed are involved in the precise and accurate enumeration of microorganisms on surfaces and in the neutralization of viable organisms buried inside solid materials that could be released to a planet's surface if the solid should be fractured. Special attention is given to sampling procedures including also the indirect techniques of surface assays of space hardware such as those using detachable or fallout strips. Some data on comparative levels of microbial contamination on lunar and planetary spacecraft are presented.

  10. The burden of the variability introduced by the HEp-2 assay kit and the CAD system in ANA indirect immunofluorescence test.

    PubMed

    Infantino, M; Meacci, F; Grossi, V; Manfredi, M; Benucci, M; Merone, M; Soda, P

    2017-02-01

    According to the recent recommendations of the American College of Rheumatology, ANA Task Force, IIF technique should be considered the gold standard in antinuclear antibodies (ANAs) testing. To overcome the lack of standardization, biomedical industries have developed several computer-aided diagnosis (CAD) systems. Two hundred and sixty-one consecutive samples with suspected autoimmune diseases were tested for ANA by means of IIF on routinely HEp-2 assay kit (Euroimmun AG). Assignment of result was made if consensus for positive/negative was reached by at least 2 out of 3 expert physicians. ANA-IIF was also carried out using 3 CAD systems: Zenit G-Sight (n = 84), Helios (n = 85) and NOVA View (n = 92); human evaluation was repeated on the same substrate of each CAD system (Immco, Aesku and Inova HEp-2 cells, respectively). To anonymize the results, we randomly named these three systems as A, B and C. We ran a statistical analysis computing several measures of agreement between the ratings, and we also improved the evaluation by using the Wilcoxon's test for nonparametric data. Agreement between the human readings on routinely HEp-2 assay kit and human readings on CAD HEp-2 assay was substantial for A (k = 0.82) and B (k = 0.72), and almost perfect for C (k = 0.89). Such readings were statistically different only in case A. Comparing experts' readings with the readings of CAD systems, when the samples were prepared using CAD HEp-2 assay kits, we found almost perfect agreement for B and C (k = 0.86; k = 0.82) and substantial agreement for A (k = 0.73). Again, human and CAD readings were statistically different only in A. When we compared the readings of medical experts on routinely HEp-2 assay kit with the output of the CAD systems that worked using their own slides, we found substantial agreement for all the systems (A: k = 0.62; B: k = 0.65; C: k = 0.71). Such readings were not statistically different. The change of the assay kit and/or the

  11. Assays for hydrophilic and lipophilic antioxidant capacity (oxygen radical absorbance capacity (ORAC(FL))) of plasma and other biological and food samples.

    PubMed

    Prior, Ronald L; Hoang, Ha; Gu, Liwei; Wu, Xianli; Bacchiocca, Mara; Howard, Luke; Hampsch-Woodill, Maureen; Huang, Dejian; Ou, Boxin; Jacob, Robert

    2003-05-21

    Methods are described for the extraction and analysis of hydrophilic and lipophilic antioxidants, using modifications of the oxygen radical absorbing capacity (ORAC(FL)) procedure. These methods provide, for the first time, the ability to obtain a measure of "total antioxidant capacity" in the protein free plasma, using the same peroxyl radical generator for both lipophilic and hydrophilic antioxidants. Separation of the lipophilic and hydrophilic antioxidant fractions from plasma was accomplished by extracting with hexane after adding water and ethanol to the plasma (hexane/plasma/ethanol/water, 4:1:2:1, v/v). Lipophilic and hydrophilic antioxidants were efficiently partitioned between hexane and aqueous solvents. Conditions for controlling temperature effects and decreasing assay variability using fluorescein as the fluorescent probe were validated in different laboratories. Incubation (37 degrees C for at least 30 min) of the buffer to which AAPH was dissolved was critical in decreasing assay variability. Lipophilic antioxidants represented 33.1 +/- 1.5 and 38.2 +/- 1.9% of the total antioxidant capacity of the protein free plasma in two independent studies of 6 and 10 subjects, respectively. Methods are described for application of the assay techniques to other types of biological and food samples.

  12. Optimization and proficiency testing of a pseudovirus-based assay for detection of HIV-1 neutralizing antibody in China.

    PubMed

    Nie, Jianhui; Wang, Wenbo; Wen, Zhiheng; Song, Aijing; Hong, Kunxue; Lu, Shan; Zhong, Ping; Xu, Jianqing; Kong, Wei; Li, Jingyun; Shang, Hong; Ling, Hong; Ruan, Li; Wang, Youchun

    2012-11-01

    Among the neutralizing antibody evaluation assays, the single-cycle pseudovirus infection assay is high-throughput and can provide rapid, sensitive and reproducible measurements after a single cycle of infection. Cell counts, pseudovirus inoculation levels, amount of diethylaminoethyl-dextran (DEAE-dextran), and the nonspecific effects of serum and plasma were tested to identify the optimal conditions for a neutralizing antibody assay based on pseudoviruses. Optimal conditions for cell counts, pseudovirus inoculation, and amount of DEAE-dextran were 1 × 10(4)cells/well, 200TCID(50)/well, and 15 μg/ml, respectively. Compared with serum samples, high-concentration anticoagulants reduced the relative light unit (RLU) value. The RLU value increased sharply initially but then decreased slowly with dilution of the plasma sample. Test kits containing 10 HIV-1 CRF07/08_BC pseudovirus strains and 10 plasma samples from individuals infected with HIV-1 CRF07/08_BC were assembled into two packages and distributed to nine laboratories with a standard operating procedure included. For the 10 laboratories that evaluated the test, 17 of 44 (37%) laboratory pairs were considered equivalent. A statistical qualification rule was developed based on the testing results from 5 experienced laboratories, where a laboratory qualified if at least 83% of values lied within the acceptable range. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Analytical techniques: A compilation

    NASA Technical Reports Server (NTRS)

    1975-01-01

    A compilation, containing articles on a number of analytical techniques for quality control engineers and laboratory workers, is presented. Data cover techniques for testing electronic, mechanical, and optical systems, nondestructive testing techniques, and gas analysis techniques.

  14. One-Step Immunochromatography Assay Kit for Detecting Antibodies to Canine Parvovirus

    PubMed Central

    Oh, Jin-Sik; Ha, Gun-Woo; Cho, Young-Shik; Kim, Min-Jae; An, Dong-Jun; Hwang, Kyu-Kye; Lim, Yoon-Kyu; Park, Bong-Kyun; Kang, BoKyu; Song, Dae-Sub

    2006-01-01

    This study was performed to determine the feasibility of using whole serum to detect antibodies to canine parvovirus (CPV) under nonlaboratory conditions and to evaluate the performance characteristics of an immunochromatography assay kit. Precise detection of levels of antibody against CPV in puppies can be used to determine a vaccination schedule, because maternal antibodies frequently result in the failure of protective vaccination, and can also be used to determine the antibody levels of infected puppies. Several methods for the titration of CPV antibodies have been reported, including the hemagglutination inhibition (HI) assay, which is considered the “gold standard.” These methods, however, require intricate and time-consuming procedures. In this study, a total of 386 serum specimens were tested. Compared to the HI assay, the rapid assay had a 97.1% sensitivity and a 76.6% specificity (with a cutoff HI titer of 1:80). This single-step assay could be performed rapidly and easily without special equipment. The kit provides a reliable method for detection of anti-CPV antibody where laboratory support and personnel are limited. PMID:16603622

  15. One-step immunochromatography assay kit for detecting antibodies to canine parvovirus.

    PubMed

    Oh, Jin-Sik; Ha, Gun-Woo; Cho, Young-Shik; Kim, Min-Jae; An, Dong-Jun; Hwang, Kyu-Kye; Lim, Yoon-Kyu; Park, Bong-Kyun; Kang, BoKyu; Song, Dae-Sub

    2006-04-01

    This study was performed to determine the feasibility of using whole serum to detect antibodies to canine parvovirus (CPV) under nonlaboratory conditions and to evaluate the performance characteristics of an immunochromatography assay kit. Precise detection of levels of antibody against CPV in puppies can be used to determine a vaccination schedule, because maternal antibodies frequently result in the failure of protective vaccination, and can also be used to determine the antibody levels of infected puppies. Several methods for the titration of CPV antibodies have been reported, including the hemagglutination inhibition (HI) assay, which is considered the "gold standard." These methods, however, require intricate and time-consuming procedures. In this study, a total of 386 serum specimens were tested. Compared to the HI assay, the rapid assay had a 97.1% sensitivity and a 76.6% specificity (with a cutoff HI titer of 1:80). This single-step assay could be performed rapidly and easily without special equipment. The kit provides a reliable method for detection of anti-CPV antibody where laboratory support and personnel are limited.

  16. Targeting Anti-Cancer Active Compounds: Affinity-Based Chromatographic Assays

    PubMed Central

    de Moraes, Marcela Cristina; Cardoso, Carmen Lucia; Seidl, Claudia; Moaddel, Ruin; Cass, Quezia Bezerra

    2016-01-01

    Affinity-based chromatography assays encompass the use of solid supports containing immobilized biological targets to monitor binding events in the isolation , identification and/or characterization of bioactive compounds. This powerful bioanalytical technique allows the screening of potential binders through fast analyses that can be directly performed using isolated substances or complex matrices. An overview of the recent researches in frontal and zonal affinity-based chromatography screening assays, which has been used as a tool in the identification and characterization of new anti-cancer agents, is discussed. In addition, a critical evaluation of the recently emerged ligands fishing assays in complex mixtures is also discussed. PMID:27306095

  17. ICECAP: an integrated, general-purpose, automation-assisted IC50/EC50 assay platform.

    PubMed

    Li, Ming; Chou, Judy; King, Kristopher W; Jing, Jing; Wei, Dong; Yang, Liyu

    2015-02-01

    IC50 and EC50 values are commonly used to evaluate drug potency. Mass spectrometry (MS)-centric bioanalytical and biomarker labs are now conducting IC50/EC50 assays, which, if done manually, are tedious and error-prone. Existing bioanalytical sample preparation automation systems cannot meet IC50/EC50 assay throughput demand. A general-purpose, automation-assisted IC50/EC50 assay platform was developed to automate the calculations of spiking solutions and the matrix solutions preparation scheme, the actual spiking and matrix solutions preparations, as well as the flexible sample extraction procedures after incubation. In addition, the platform also automates the data extraction, nonlinear regression curve fitting, computation of IC50/EC50 values, graphing, and reporting. The automation-assisted IC50/EC50 assay platform can process the whole class of assays of varying assay conditions. In each run, the system can handle up to 32 compounds and up to 10 concentration levels per compound, and it greatly improves IC50/EC50 assay experimental productivity and data processing efficiency. © 2014 Society for Laboratory Automation and Screening.

  18. Sodium and potassium content of 24 h urinary collections: a comparison between field- and laboratory-based analysers.

    PubMed

    Yin, Xuejun; Neal, Bruce; Tian, Maoyi; Li, Zhifang; Petersen, Kristina; Komatsu, Yuichiro; Feng, Xiangxian; Wu, Yangfeng

    2018-04-01

    Measurement of mean population Na and K intakes typically uses laboratory-based assays, which can add significant logistical burden and costs. A valid field-based measurement method would be a significant advance. In the current study, we used 24 h urine samples to compare estimates of Na, K and Na:K ratio based upon assays done using the field-based Horiba twin meter v. laboratory-based methods. The performance of the Horiba twin meter was determined by comparing field-based estimates of mean Na and K against those obtained using laboratory-based methods. The reported 95 % limits of agreement of Bland-Altman plots were calculated based on a regression approach for non-uniform differences. The 24 h urine samples were collected as part of an ongoing study being done in rural China. One hundred and sixty-six complete 24 h urine samples were qualified for estimating 24 h urinary Na and K excretion. Mean Na and K excretion were estimated as 170·4 and 37·4 mmol/d, respectively, using the meter-based assays; and 193·4 and 43·8 mmol/d, respectively, using the laboratory-based assays. There was excellent relative reliability (intraclass correlation coefficient) for both Na (0·986) and K (0·986). Bland-Altman plots showed moderate-to-good agreement between the two methods. Na and K intake estimations were moderately underestimated using assays based upon the Horiba twin meter. Compared with standard laboratory-based methods, the portable device was more practical and convenient.

  19. Detection of hypoxic fractions in murine tumors by comet assay: Comparison with other techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, Q.; Kavanagh, M.C.; Newcombe, D.

    1995-12-01

    The alkaline comet assay was used to detect the hypoxic fractions of murine tumors. A total of four tumor types were tested using needle aspiration biopsies taken immediately after a radiation dose of 15 Gy. Initial studies confirmed that the normalized tail moment, a parameter reflecting single-strand DNA breaks induced by the radiation, was linearly related to radiation dose. Further, it was shown that for a mixed population (1:1) of cells irradiated under air-breathing or hypoxic conditions, the histogram of normal tail moment values obtained from analyzing 400 cells in the population had a double peak which, when fitted withmore » two Gaussian distributions, gave a good estimate of the proportion of the two subpopulations. For the four tumor types, the means of the calculated hypoxic fractions from four or five individual tumors were 0.15 {+-} 0.04 for B16F1, 0.08 {+-} 0.04 for KHT-LP1, 0.17 {+-} 0.04 for RIF-1 and 0.04 {+-} 0.01 for SCCVII. Analysis of variance showed that the hypoxic fraction in KHT-LP1 tumors is significantly lower than those of the other three tumors (P = 0.026) but that there is no significant difference in hypoxic fraction between B16F1, RIF-1 and SCCVII tumors (P = 0.574). Results from multiple samples taken from each of five RIF-1 tumors showed that the intertumor heterogeneity of hypoxic fractions was greater than that within the same tumor. The mean hypoxic fraction obtained using the comet assay for the four tumor types was compared with the hypoxic fraction determined by the clonogenic assay, or median pO{sub 2} values, or [{sup 3}H]misonidazole binding in the same tumor types. The values of hypoxic fraction obtained with the comet assay were two to four times lower than those measured by the paired survival method. Preliminary results obtained with a dose of 5 Gy were consistent with those obtained using 15 Gy. These results suggest the further development of the comet assay for clinical studies. 21 refs., 7 figs., 5 tabs.« less

  20. Virus Characterization by FFF-MALS Assay

    NASA Astrophysics Data System (ADS)

    Razinkov, Vladimer

    2009-03-01

    Adequate biophysical characterization of influenza virions is important for vaccine development. The influenza virus vaccines are produced from the allantoic fluid of developing chicken embryos. The process of viral replication produces a heterogeneous mixture of infectious and non-infectious viral particles with varying states of aggregation. The study of the relative distribution and behavior of different subpopulations and their inter-correlation can assist in the development of a robust process for a live virus vaccine. This report describes a field flow fractionation and multiangle light scattering (FFF-MALS) method optimized for the analysis of size distribution and total particle counts. A method using a combination of asymmetric flow field-flow fractionation (AFFFF) and multiangle light scattering (MALS) techniques has been shown to improve the estimation of virus particle counts and the amount of aggregated virus in laboratory samples. The FFF-MALS method was compared with several other methods such as transmission electron microscopy (TEM), atomic force microscopy (AFM), size exclusion chromatography followed by MALS (SEC-MALS), quantitative reverse transcription polymerase chain reaction (RT Q-PCR), median tissue culture dose (TCID(50)), and the fluorescent focus assay (FFA). The correlation between the various methods for determining total particle counts, infectivity and size distribution is reported. The pros and cons of each of the analytical methods are discussed.

  1. A step-by-step protocol for assaying protein carbonylation in biological samples.

    PubMed

    Colombo, Graziano; Clerici, Marco; Garavaglia, Maria Elisa; Giustarini, Daniela; Rossi, Ranieri; Milzani, Aldo; Dalle-Donne, Isabella

    2016-04-15

    Protein carbonylation represents the most frequent and usually irreversible oxidative modification affecting proteins. This modification is chemically stable and this feature is particularly important for storage and detection of carbonylated proteins. Many biochemical and analytical methods have been developed during the last thirty years to assay protein carbonylation. The most successful method consists on protein carbonyl (PCO) derivatization with 2,4-dinitrophenylhydrazine (DNPH) and consequent spectrophotometric assay. This assay allows a global quantification of PCO content due to the ability of DNPH to react with carbonyl giving rise to an adduct able to absorb at 366 nm. Similar approaches were also developed employing chromatographic separation, in particular HPLC, and parallel detection of absorbing adducts. Subsequently, immunological techniques, such as Western immunoblot or ELISA, have been developed leading to an increase of sensitivity in protein carbonylation detection. Currently, they are widely employed to evaluate change in total protein carbonylation and eventually to highlight the specific proteins undergoing selective oxidation. In the last decade, many mass spectrometry (MS) approaches have been developed for the identification of the carbonylated proteins and the relative amino acid residues modified to carbonyl derivatives. Although these MS methods are much more focused and detailed due to their ability to identify the amino acid residues undergoing carbonylation, they still require too expensive equipments and, therefore, are limited in distribution. In this protocol paper, we summarise and comment on the most diffuse protocols that a standard laboratory can employ to assess protein carbonylation; in particular, we describe step-by-step the different protocols, adding suggestions coming from our on-bench experience. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Doing that thing that scientists do: A discovery-driven module on protein purification and characterization for the undergraduate biochemistry laboratory classroom.

    PubMed

    Garrett, Teresa A; Osmundson, Joseph; Isaacson, Marisa; Herrera, Jennifer

    2015-01-01

    In traditional introductory biochemistry laboratory classes students learn techniques for protein purification and analysis by following provided, established, step-by-step procedures. Students are exposed to a variety of biochemical techniques but are often not developing procedures or collecting new, original data. In this laboratory module, students develop research skills through work on an original research project and gain confidence in their ability to design and execute an experiment while faculty can enhance their scholarly pursuits through the acquisition of original data in the classroom laboratory. Students are prepared for a 6-8 week discovery-driven project on the purification of the Escherichia coli cytidylate kinase (CMP kinase) through in class problems and other laboratory exercises on bioinformatics and protein structure analysis. After a minimal amount of guidance on how to perform the CMP kinase in vitro enzyme assay, SDS-PAGE, and the basics of protein purification, students, working in groups of three to four, develop a protein purification protocol based on the scientific literature and investigate some aspect of CMP kinase that interests them. Through this process, students learn how to implement a new but perhaps previously worked out procedure to answer their research question. In addition, they learn the importance of keeping a clear and thorough laboratory notebook and how to interpret their data and use that data to inform the next set of experiments. Following this module, students had increased confidence in their ability to do basic biochemistry techniques and reported that the "self-directed" nature of this lab increased their engagement in the project. © 2015 The International Union of Biochemistry and Molecular Biology.

  3. Rapid in situ assessment for predicting soil quality using an algae-soaked disc seeding assay.

    PubMed

    Nam, Sun-Hwa; Moon, Jongmin; Kim, Shin Woong; Kim, Hakyeong; Jeong, Seung-Woo; An, Youn-Joo

    2017-11-16

    The soil quality of remediated land is altered and this land consequently exerts unexpected biological effects on terrestrial organisms. Therefore, field evaluation of such land should be conducted using biological indicators. Algae are a promising new biological indicator since they are a food source for organisms in higher soil trophic levels and easily sampled from the soil. Field evaluation of soil characteristics is preferred to be testing in laboratory conditions because many biological effects cannot be duplicated during laboratory evaluations. Herein, we describe a convenient and rapid algae-soaked disc seeding assay for assessing soil quality in the field based on soil algae. The collection of algae is easy and rapid and the method predicts the short-term quality of contaminated, remediated, and amended farm and paddy soils. The algae-soaked disc seeding assay is yet to be extensively evaluated, and the method cannot be applied to loamy sand soil in in situ evaluations. The algae-soaked disc seeding assay is recommended for prediction of soil quality in in situ evaluations because it reflects all variations in the environment. The algae-soaked disc seeding assay will help to develop management strategies for in situ evaluation.

  4. Development and validation of a Luminex assay for detection of a predictive biomarker for PROSTVAC-VF therapy

    PubMed Central

    Lucas, Julie L.; Tacheny, Erin A.; Ferris, Allison; Galusha, Michelle; Srivastava, Apurva K.; Ganguly, Aniruddha; Williams, P. Mickey; Sachs, Michael C.; Thurin, Magdalena; Tricoli, James V.; Ricker, Winnie; Gildersleeve, Jeffrey C.

    2017-01-01

    Cancer therapies can provide substantially improved survival in some patients while other seemingly similar patients receive little or no benefit. Strategies to identify patients likely to respond well to a given therapy could significantly improve health care outcomes by maximizing clinical benefits while reducing toxicities and adverse effects. Using a glycan microarray assay, we recently reported that pretreatment serum levels of IgM specific to blood group A trisaccharide (BG-Atri) correlate positively with overall survival of cancer patients on PROSTVAC-VF therapy. The results suggested anti-BG-Atri IgM measured prior to treatment could serve as a biomarker for identifying patients likely to benefit from PROSTVAC-VF. For continued development and clinical application of serum IgM specific to BG-Atri as a predictive biomarker, a clinical assay was needed. In this study, we developed and validated a Luminex-based clinical assay for measuring serum IgM specific to BG-Atri. IgM levels were measured with the Luminex assay and compared to levels measured using the microarray for 126 healthy individuals and 77 prostate cancer patients. This assay provided reproducible and consistent results with low %CVs, and tolerance ranges were established for the assay. IgM levels measured using the Luminex assay were found to be highly correlated to the microarray results with R values of 0.93–0.95. This assay is a Laboratory Developed Test (LDT) and is suitable for evaluating thousands of serum samples in CLIA certified laboratories that have validated the assay. In addition, the study demonstrates that discoveries made using neoglycoprotein-based microarrays can be readily migrated to a clinical assay. PMID:28771597

  5. Accelerator-based techniques for the support of senior-level undergraduate physics laboratories

    NASA Astrophysics Data System (ADS)

    Williams, J. R.; Clark, J. C.; Isaacs-Smith, T.

    2001-07-01

    Approximately three years ago, Auburn University replaced its aging Dynamitron accelerator with a new 2MV tandem machine (Pelletron) manufactured by the National Electrostatics Corporation (NEC). This new machine is maintained and operated for the University by Physics Department personnel, and the accelerator supports a wide variety of materials modification/analysis studies. Computer software is available that allows the NEC Pelletron to be operated from a remote location, and an Internet link has been established between the Accelerator Laboratory and the Upper-Level Undergraduate Teaching Laboratory in the Physics Department. Additional software supplied by Canberra Industries has also been used to create a second Internet link that allows live-time data acquisition in the Teaching Laboratory. Our senior-level undergraduates and first-year graduate students perform a number of experiments related to radiation detection and measurement as well as several standard accelerator-based experiments that have been added recently. These laboratory exercises will be described, and the procedures used to establish the Internet links between our Teaching Laboratory and the Accelerator Laboratory will be discussed.

  6. Real-Time Reverse Transcription-PCR Assay for Detection of Mumps Virus RNA in Clinical Specimens▿

    PubMed Central

    Boddicker, Jennifer D.; Rota, Paul A.; Kreman, Trisha; Wangeman, Andrea; Lowe, Louis; Hummel, Kimberly B.; Thompson, Robert; Bellini, William J.; Pentella, Michael; DesJardin, Lucy E.

    2007-01-01

    The mumps virus is a negative-strand RNA virus in the family Paramyxoviridae. Mumps infection results in an acute illness with symptoms including fever, headache, and myalgia, followed by swelling of the salivary glands. Complications of mumps can include meningitis, deafness, pancreatitis, orchitis, and first-trimester abortion. Laboratory confirmation of mumps infection can be made by the detection of immunoglobulin M-specific antibodies to mumps virus in acute-phase serum samples, the isolation of mumps virus in cell culture, or by detection of the RNA of the mumps virus by reverse transcription (RT)-PCR. We developed and validated a multiplex real-time RT-PCR assay for rapid mumps diagnosis in a clinical setting. This assay used oligonucleotide primers and a TaqMan probe targeting the mumps SH gene, as well as primers and a probe that targeted the human RNase P gene to assess the presence of PCR inhibitors and as a measure of specimen quality. The test was specific, since it did not amplify a product from near-neighbor viruses, as well as sensitive and accurate. Real-time RT-PCR results showed 100% correlation with results from viral culture, the gold standard for mumps diagnostic testing. Assay efficiency was over 90% and displayed good precision after performing inter- and intraassay replicates. Thus, we have developed and validated a molecular method for rapidly diagnosing mumps infection that may be used to complement existing techniques. PMID:17652480

  7. Integrating Introductory Biology and General Chemistry Laboratories.

    ERIC Educational Resources Information Center

    Godrick, Elizabeth; Hartman, Standish

    2000-01-01

    Introduces a science laboratory integrating biology and chemistry courses that includes four modules: (1) the fundamental process of reactions; (2) a semester-long project on the chemical assay of ascorbic acid; (3) human metabolism of Vitamin C; and (4) an open-ended project on the manipulation of macromolecules. (YDS)

  8. Electronic reporting of all reference laboratory results: An important step toward a truly all-encompassing, integrated health record.

    PubMed

    Kratz, Alexander

    2016-09-01

    Results from reference laboratories are often not easily available in electronic health records. This article describes a multi-pronged, long-term approach that includes bringing send-out tests in-house, upgrading the laboratory information system, interfacing more send-out tests and more reference laboratories, utilizing the "miscellaneous assay" option offered by some reference laboratories, and scanning all remaining paper reports from reference laboratories for display in the electronic health record. This allowed all laboratory results obtained in association with a patient visit, whether performed in-house or at a reference laboratory, to be available in the integrated electronic health record. This was achieved without manual data entry of reference laboratory results, thereby avoiding the risk of transcription errors. A fully integrated electronic health record that contains all laboratory results can be achieved by maximizing the number of interfaced reference laboratory assays and making all non-interfaced results available as scanned documents. © The Author(s) 2015.

  9. Monitoring of anticoagulant therapy in heart disease: considerations for the current assays.

    PubMed

    Boroumand, Mohammadali; Goodarzynejad, Hamidreza

    2010-01-01

    Clinicians should be aware of new developments to familiarize themselves with pharmacokinetic and pharmacodynamic characteristics of new anticoagulant agents to appropriately and safely use them. For the moment, cardiologists and other clinicians also require to master currently available drugs, realizing the mechanism of action, side effects, and laboratory monitoring to measure their anticoagulant effects. Warfarin and heparin have narrow therapeutic window with high inter- and intra-patient variability, thereby the use of either drug needs careful laboratory monitoring and dose adjustment to ensure proper antithrombotic protection while minimizing the bleeding risk. The prothrombin time (PT) and the activated partial thromboplastin time (aPTT) are laboratory tests commonly used to monitor warfarin and heparin, respectively. These two tests depend highly on the combination of reagent and instrument utilized. Results for a single specimen tested in different laboratories are variable; this is mostly attributable to the specific reagents and to a much lesser degree to the instrument used. The PT stands alone as the single coagulation test that has undergone the most extensive attempt at assay standardization. The international normalized ratio (INR) was introduced to "normalize" all PT reagents to a World Health Organization (WHO) reference thromboplastin preparation standard, such that a PT measured anywhere in the world would result in an INR value similar to that which would have been achieved had the WHO reference thromboplastin been utilized. However, INRs are reproducible between laboratories for only those patients who are stably anticoagulated with vitamin K antagonists (VKAs) (i.e., at least 6 weeks of VKA therapy), and are not reliable or reproducible between laboratories for patients for whom VKA therapy has recently been started or any other clinical conditions associated with a prolonged PT such as liver disease, disseminated intravascular coagulation

  10. Validation of a quantitative cerebrospinal fluid alpha-synuclein assay in a European-wide interlaboratory study.

    PubMed

    Kruse, Niels; Persson, Staffan; Alcolea, Daniel; Bahl, Justyna M C; Baldeiras, Ines; Capello, Elisabetta; Chiasserini, Davide; Bocchio Chiavetto, Luisella; Emersic, Andreja; Engelborghs, Sebastiaan; Eren, Erden; Fladby, Tormod; Frisoni, Giovanni; García-Ayllón, María-Salud; Genc, Sermin; Gkatzima, Olymbia; Heegaard, Niels H H; Janeiro, André M; Kováčech, Branislav; Kuiperij, H Bea; Leitão, Maria J; Lleó, Alberto; Martins, Madalena; Matos, Mafalda; Mollergard, Hanne M; Nobili, Flavio; Öhrfelt, Annika; Parnetti, Lucilla; de Oliveira, Catarina Resende; Rot, Uros; Sáez-Valero, Javier; Struyfs, Hanne; Tanassi, Julia T; Taylor, Peggy; Tsolaki, Magda; Vanmechelen, Eugeen; Verbeek, Marcel M; Zilka, Norbert; Blennow, Kaj; Zetterberg, Henrik; Mollenhauer, Brit

    2015-09-01

    Decreased levels of alpha-synuclein (aSyn) in cerebrospinal fluid (CSF) in Parkinson's disease and related synucleinopathies have been reported, however, not consistently in all cross-sectional studies. To test the performance of one recently released human-specific enzyme-linked immunosorbent assay (ELISA) for the quantification of aSyn in CSF, we carried out a round robin trial with 18 participating laboratories trained in CSF ELISA analyses within the BIOMARKAPD project in the EU Joint Program - Neurodegenerative Disease Research. CSF samples (homogeneous aliquots from pools) and ELISA kits (one lot) were provided centrally and data reported back to one laboratory for data analysis. Our study showed that although factors such as preanalytical sample handling and lot-to-lot variability were minimized by our study design, we identified high variation in absolute values of CSF aSyn even when the same samples and same lots of assays were applied. We further demonstrate that although absolute concentrations differ between laboratories the quantitative results are comparable. With further standardization this assay may become an attractive tool for comparing aSyn measurements in diverse settings. Recommendations for further validation experiments and improvement of the interlaboratory results obtained are given. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Multiplex PCR assay to identify methicillin-resistant Staphylococcus haemolyticus.

    PubMed

    Schuenck, Ricardo P; Pereira, Eliezer M; Iorio, Natalia L P; Dos Santos, Kátia R N

    2008-04-01

    Staphylococcus haemolyticus is the most frequently coagulase-negative Staphylococcus species associated with antimicrobial resistance isolated from nosocomial infections. We developed an accurate and simple multiplex PCR assay to identify methicillin-resistant S. haemolyticus (MRSH) isolates. We designed species-specific primers of the mvaA gene that encodes a 3-hydroxy-3-methylglutaryl coenzyme A involved in the mevalonate pathway of the microorganism. Simultaneously, mecA gene primers of methicillin resistance were also used. The PCR assay was established using 16 strains of different reference Staphylococcus species and validated with a collection of 147 clinical staphylococcal isolates that were also phenotypically characterized. Reliable results for the detection of MRSH isolates were obtained for 100% of the strains evaluated, showing that this PCR assay can be used for the routine microbiology laboratories. This is the first report using species-specific multiplex PCR to detect a single segment of S. haemolyticus associated with a segment of mecA gene.

  12. Analytical applications of MIPs in diagnostic assays: future perspectives.

    PubMed

    Bedwell, Thomas S; Whitcombe, Michael J

    2016-03-01

    Many efforts have been made to produce artificial materials with biomimetic properties for applications in binding assays. Among these efforts, the technique of molecular imprinting has received much attention because of the high selectivity obtainable for molecules of interest, robustness of the produced polymers, simple and short synthesis, and excellent cost efficiency. In this review, progress in the field of molecularly imprinted sorbent assays is discussed-with a focus on work conducted from 2005 to date.

  13. The Most Proficient Enzyme as the Central Theme in an Integrated, Research-based Biochemistry Laboratory Course

    ERIC Educational Resources Information Center

    Smiley, Jeffrey A.

    2002-01-01

    The enzyme orotidine-5'-monophosphate decarboxylase is an attractive choice for the central theme of an integrated, research-based biochemistry laboratory course. A series of laboratory exercises common to most instructional laboratories, including enzyme assays, protein purification, enzymatic characterization, elementary kinetics, and…

  14. [Interest of the cholinesterase assay during organophosphate poisonings].

    PubMed

    Jalady, A-M; Dorandeu, F

    2013-12-01

    Cholinesterases are the main targets of organophosphorus compounds. The two enzymes present in the blood (butyrylcholinesterase, BChE; acetylcholinesterase, AChE) are biomarkers of their systemic toxicity. Activity of the plasma BChE is very often determined as it allows a rapid diagnostic of poisoning and is a marker of the persistence of the toxicant in the blood. The activity of the red blood cell AChE gives a better picture of the synaptic inhibition in the nervous system but the assay is less commonly available in routine laboratories. Better biomarker of the exposure, it allows a diagnosis of the severity of the poisoning and helps to assess the efficacy of oxime therapy. Besides the practical aspects of blood collection and sample processing, and the interpretation of the assays, this review stresses the complementarity of both enzyme assays and recalls their crucial interest for the confirmation of poisoning with an organophosphorus in a situation of war or terrorist attack and for the monitoring of occupational exposures. Copyright © 2013. Published by Elsevier SAS.

  15. Laboratory challenges in the scaling up of HIV, TB, and malaria programs: The interaction of health and laboratory systems, clinical research, and service delivery.

    PubMed

    Birx, Deborah; de Souza, Mark; Nkengasong, John N

    2009-06-01

    Strengthening national health laboratory systems in resource-poor countries is critical to meeting the United Nations Millennium Development Goals. Despite strong commitment from the international community to fight major infectious diseases, weak laboratory infrastructure remains a huge rate-limiting step. Some major challenges facing laboratory systems in resource-poor settings include dilapidated infrastructure; lack of human capacity, laboratory policies, and strategic plans; and limited synergies between clinical and research laboratories. Together, these factors compromise the quality of test results and impact patient management. With increased funding, the target of laboratory strengthening efforts in resource-poor countries should be the integrating of laboratory services across major diseases to leverage resources with respect to physical infrastructure; types of assays; supply chain management of reagents and equipment; and maintenance of equipment.

  16. Evaluation of flow cytometric HIT assays in relation to an IgG-Specific immunoassay and clinical outcome.

    PubMed

    Kerényi, Adrienne; Beke Debreceni, Ildikó; Oláh, Zsolt; Ilonczai, Péter; Bereczky, Zsuzsanna; Nagy, Béla; Muszbek, László; Kappelmayer, János

    2017-09-01

    Heparin-induced thrombocytopenia (HIT) is a severe side effect of heparin treatment caused by platelet activating IgG antibodies generated against the platelet factor 4 (PF4)-heparin complex. Thrombocytopenia and thrombosis are the leading clinical symptoms of HIT. The clinical pretest probability of HIT was evaluated by the 4T score system. Laboratory testing of HIT was performed by immunological detection of antibodies against PF4-heparin complex (EIA) and two functional assays. Heparin-dependent activation of donor platelets by patient plasma was detected by flow cytometry. Increased binding of Annexin-V to platelets and elevated number of platelet-derived microparticles (PMP) were the indicators of platelet activation. EIA for IgG isotype HIT antibodies was performed in 405 suspected HIT patients. Based on negative EIA results, HIT was excluded in 365 (90%) of cases. In 40 patients with positive EIA test result functional tests were performed. Platelet activating antibodies were detected in 17 cases by Annexin V binding. PMP count analysis provided nearly identical results. The probability of a positive flow cytometric assay result was higher in patients with elevated antibody titer. 71% of patients with positive EIA and functional assay had thrombosis. EIA is an important first line laboratory test in the diagnosis of HIT; however, HIT must be confirmed by a functional test. Annexin V binding and PMP assays using flow cytometry are functional HIT tests convenient in a clinical diagnostic laboratory. The positive results of functional assays may predict the onset of thrombosis. © 2016 International Clinical Cytometry Society. © 2016 International Clinical Cytometry Society.

  17. Melt Analysis of Mismatch Amplification Mutation Assays (Melt-MAMA): A Functional Study of a Cost-Effective SNP Genotyping Assay in Bacterial Models

    PubMed Central

    Birdsell, Dawn N.; Pearson, Talima; Price, Erin P.; Hornstra, Heidie M.; Nera, Roxanne D.; Stone, Nathan; Gruendike, Jeffrey; Kaufman, Emily L.; Pettus, Amanda H.; Hurbon, Audriana N.; Buchhagen, Jordan L.; Harms, N. Jane; Chanturia, Gvantsa; Gyuranecz, Miklos; Wagner, David M.; Keim, Paul S.

    2012-01-01

    Single nucleotide polymorphisms (SNPs) are abundant in genomes of all species and biologically informative markers extensively used across broad scientific disciplines. Newly identified SNP markers are publicly available at an ever-increasing rate due to advancements in sequencing technologies. Efficient, cost-effective SNP genotyping methods to screen sample populations are in great demand in well-equipped laboratories, but also in developing world situations. Dual Probe TaqMan assays are robust but can be cost-prohibitive and require specialized equipment. The Mismatch Amplification Mutation Assay, coupled with melt analysis (Melt-MAMA), is flexible, efficient and cost-effective. However, Melt-MAMA traditionally suffers from high rates of assay design failures and knowledge gaps on assay robustness and sensitivity. In this study, we identified strategies that improved the success of Melt-MAMA. We examined the performance of 185 Melt-MAMAs across eight different pathogens using various optimization parameters. We evaluated the effects of genome size and %GC content on assay development. When used collectively, specific strategies markedly improved the rate of successful assays at the first design attempt from ∼50% to ∼80%. We observed that Melt-MAMA accurately genotypes across a broad DNA range (∼100 ng to ∼0.1 pg). Genomic size and %GC content influence the rate of successful assay design in an independent manner. Finally, we demonstrated the versatility of these assays by the creation of a duplex Melt-MAMA real-time PCR (two SNPs) and conversion to a size-based genotyping system, which uses agarose gel electrophoresis. Melt-MAMA is comparable to Dual Probe TaqMan assays in terms of design success rate and accuracy. Although sensitivity is less robust than Dual Probe TaqMan assays, Melt-MAMA is superior in terms of cost-effectiveness, speed of development and versatility. We detail the parameters most important for the successful application of Melt

  18. Performance of the new automated Abbott RealTime MTB assay for rapid detection of Mycobacterium tuberculosis complex in respiratory specimens.

    PubMed

    Chen, J H K; She, K K K; Kwong, T-C; Wong, O-Y; Siu, G K H; Leung, C-C; Chang, K-C; Tam, C-M; Ho, P-L; Cheng, V C C; Yuen, K-Y; Yam, W-C

    2015-09-01

    The automated high-throughput Abbott RealTime MTB real-time PCR assay has been recently launched for Mycobacterium tuberculosis complex (MTBC) clinical diagnosis. This study would like to evaluate its performance. We first compared its diagnostic performance with the Roche Cobas TaqMan MTB assay on 214 clinical respiratory specimens. Prospective analysis of a total 520 specimens was then performed to further evaluate the Abbott assay. The Abbott assay showed a lower limit of detection at 22.5 AFB/ml, which was more sensitive than the Cobas assay (167.5 AFB/ml). The two assays demonstrated a significant difference in diagnostic performance (McNemar's test; P = 0.0034), in which the Abbott assay presented significantly higher area under curve (AUC) than the Cobas assay (1.000 vs 0.880; P = 0.0002). The Abbott assay demonstrated extremely low PCR inhibition on clinical respiratory specimens. The automated Abbott assay required only very short manual handling time (0.5 h), which could help to improve the laboratory management. In the prospective analysis, the overall estimates for sensitivity and specificity of the Abbott assay were both 100 % among smear-positive specimens, whereas the smear-negative specimens were 96.7 and 96.1 %, respectively. No cross-reactivity with non-tuberculosis mycobacterial species was observed. The superiority in sensitivity of the Abbott assay for detecting MTBC in smear-negative specimens could further minimize the risk in MTBC false-negative detection. The new Abbott RealTime MTB assay has good diagnostic performance which can be a useful diagnostic tool for rapid MTBC detection in clinical laboratories.

  19. Current insights into the laboratory diagnosis of HIT.

    PubMed

    Bakchoul, T; Zöllner, H; Greinacher, A

    2014-06-01

    Heparin-induced thrombocytopenia (HIT) is an adverse drug reaction and prothrombotic disorder caused by immunization against platelet factor 4 (PF4) after complex formation with heparin or other polyanions. After antibody binding to PF4/heparin complexes, HIT antibodies are capable of intravascular platelet activation by cross-linking Fc gamma receptor IIa (FcγRIIa) on the platelet surface leading to a platelet count decrease and/or thrombosis. In contrast to most other immune-mediated disorders, the currently available laboratory tests for anti-PF4/heparin antibodies show a high sensitivity also for clinically irrelevant antibodies. This makes the diagnosis of HIT challenging and bears the risk to substantially overdiagnose HIT. The strength of the antigen assays for HIT is in ruling out HIT when the test is negative. Functional assays have a higher specificity for clinically relevant antibodies, but they are restricted to specialized laboratories. Currently, a Bayesian approach combining the clinical likelihood estimation for HIT with laboratory tests is the most appropriate approach to diagnose HIT. In this review, we give an overview on currently available diagnostic procedures and discuss their limitations. © 2014 John Wiley & Sons Ltd.

  20. Postdoctoral Professional Fellowships in Laboratory Medicine.

    PubMed

    Straseski, Joely A

    2013-04-01

    Doctoral level scientists often pursue a traditional academic route, focusing their efforts on research and education. However, additional options exist for those that are interested in using their laboratory and research skills in a clinical setting. Clinical laboratory directors serve as the interface between the clinical laboratory and the users of laboratory test results. This article describes these career paths options for PhD scientists. Clinical laboratory directors are primarily trained via one of two routes: physicians that have been trained in clinical pathology or non-physician doctoral scientists that have completed professional fellowship training. This article will focus on the latter of these 2 routes. In the United States, completing a postdoctoral fellowship in laboratory-specific professional fields qualifies non-physician doctoral scientists as laboratory directors and consultants. Their expert consultation provides invaluable insight into testing procedures such as possible sources of interference or inaccurate test results, preferred testing for specific clinical situations, and confirmatory methods. They must also be knowledgeable about current instrumentation, assay limitations, and the newest available technologies. One of the older and more developed professional fellowships in the United States, clinical chemistry, encompasses many laboratory disciplines and will be highlighted in detail. Training information specific to clinical immunology, clinical microbiology, and clinical genetics is also discussed.