Sample records for laboratory building 777-10a

  1. Decommissioning the physics laboratory, building 777-10A, at the Savannah River Site (SRS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Musall, John C.; Cope, Jeff L.

    2008-01-15

    SRS recently completed a four year mission to decommission {approx}250 excess facilities. As part of that effort, SRS decommissioned a 48,000 ft{sup 2} laboratory that housed four low-power test reactors, formerly used by SRS to determine reactor physics. This paper describes and reviews the decommissioning, with a focus on component segmentation and handling (i.e. hazardous material removal, demolition, and waste handling). The paper is intended to be a resource for engineers, planners, and project managers, who face similar decommissioning challenges. Building 777-10A, located at the south end of SRS's A/M-Area, was built in 1953 and had a gross area of {approx}48,000 ft{sup 2}. Building 777-10A had two main areas: a west wing, which housed four experimental reactors and associated equipment; and an east wing, which housed laboratories, and shops, offices. The reactors were located in two separate areas: one area housed the Process Development Pile (PDP) reactor and the Lattice Test Reactor (LTR), while the second area housed the Standard Pile (SP) and the Sub-critical Experiment (SE) reactors. The west wing had five levels: three below and three above grade (floor elevations of -37', -28', -15', 0', +13'/+16' and +27' (roof elevation of +62')), while the east wing had two levels: one below and one above grade (floor elevations of -15' and 0' (roof elevation of +16')). Below-grade exterior walls were constructed of reinforced concrete, {approx}1' thick. In general, above-grade exterior walls were steel frames covered by insulation and corrugated, asbestos-cement board. The two interior walls around the PDP/LTR were reinforced concrete {approx}5' thick and {approx}30' high, while the SP/SE reactors resided in a reinforced, concrete cell with 3.5'-6' thick walls/roof. All other interior walls were constructed of metal studs covered with either asbestos-cement or gypsum board. In general, the floors were constructed of reinforced concrete on cast-in-place concrete

  2. ARCHITECTURAL, 777M, PHYSICS ASSEMBLY LABORATORY BUILDING, EQUIPMENT ARRANGEMENT – SECTIONS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ARCHITECTURAL, 777-M, PHYSICS ASSEMBLY LABORATORY BUILDING, EQUIPMENT ARRANGEMENT – SECTIONS “B” AND “C” (W157132) - Physics Assembly Laboratory, Area A/M, Savannah River Site, Aiken, Aiken County, SC

  3. ARCHITECTURAL, 777M, PHYSICS ASSEMBLY LABORATORY BUILDING, PLAN OF +13’1” AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ARCHITECTURAL, 777-M, PHYSICS ASSEMBLY LABORATORY BUILDING, PLAN OF +13’-1” AND +27’-0” FLOOR LEVELS (W157114) - Physics Assembly Laboratory, Area A/M, Savannah River Site, Aiken, Aiken County, SC

  4. VIEW OF BUILDING NO. 77710A, LOOKING WEST. LABORATORY WING AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF BUILDING NO. 777-10A, LOOKING WEST. LABORATORY WING AND MAIN ENTRANCE ON RIGHT; MULTISTORY REACTOR WING IN LEFT BACKGROUND - Physics Assembly Laboratory, Area A/M, Savannah River Site, Aiken, Aiken County, SC

  5. 30 CFR 777.10 - Information collection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Information collection. 777.10 Section 777.10 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR SURFACE... GENERAL CONTENT REQUIREMENTS FOR PERMIT APPLICATIONS § 777.10 Information collection. The information...

  6. 30 CFR 777.10 - Information collection.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 3 2012-07-01 2012-07-01 false Information collection. 777.10 Section 777.10... GENERAL CONTENT REQUIREMENTS FOR PERMIT APPLICATIONS § 777.10 Information collection. The information... 44 U.S.C. 3507 and assigned clearance number 1029-0032. The information is being collected to meet...

  7. 30 CFR 777.10 - Information collection.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 3 2011-07-01 2011-07-01 false Information collection. 777.10 Section 777.10... GENERAL CONTENT REQUIREMENTS FOR PERMIT APPLICATIONS § 777.10 Information collection. The information... 44 U.S.C. 3507 and assigned clearance number 1029-0032. The information is being collected to meet...

  8. GENERAL VIEW OF SITE, LOOKING WEST, WITH BUILDING NO. 77710A ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    GENERAL VIEW OF SITE, LOOKING WEST, WITH BUILDING NO. 777-10A ON LEFT. THE MULTISTORY REACTOR WING OF 777-10A IS ON THE FAR LEFT; THE ONE-STORY LABORATORY WING OF 777-10A IS IN CENTER OF VIEW. BUILDING NO. 305-A IS ON THE RIGHT - Physics Assembly Laboratory, Area A/M, Savannah River Site, Aiken, Aiken County, SC

  9. 49 CFR 236.777 - Operator, control.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Operator, control. 236.777 Section 236.777..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.777 Operator, control. An employee assigned to operate the control machine of a traffic control system. ...

  10. 49 CFR 236.777 - Operator, control.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Operator, control. 236.777 Section 236.777..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.777 Operator, control. An employee assigned to operate the control machine of a traffic control system. ...

  11. 49 CFR 236.777 - Operator, control.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Operator, control. 236.777 Section 236.777..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.777 Operator, control. An employee assigned to operate the control machine of a traffic control system. ...

  12. 49 CFR 236.777 - Operator, control.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Operator, control. 236.777 Section 236.777..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.777 Operator, control. An employee assigned to operate the control machine of a traffic control system. ...

  13. 1. VIEW LOOKING NORTHWEST AT BUILDING 701. BUILDING 701 WAS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. VIEW LOOKING NORTHWEST AT BUILDING 701. BUILDING 701 WAS USED TO DESIGN, BUILD, AND EVALUATE BENCH-SCALE TECHNOLOGIES USED IN ROCKY FLATS WASTE TREATMENT PROCESSES. (1/98) - Rocky Flats Plant, Design Laboratory, Northwest quadrant of Plant, between buildings 776-777 & 771, Golden, Jefferson County, CO

  14. Laboratory Building

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Herrera, Joshua M.

    2015-03-01

    This report is an analysis of the means of egress and life safety requirements for the laboratory building. The building is located at Sandia National Laboratories (SNL) in Albuquerque, NM. The report includes a prescriptive-based analysis as well as a performance-based analysis. Following the analysis are appendices which contain maps of the laboratory building used throughout the analysis. The top of all the maps is assumed to be north.

  15. Analysis of Thiodiglycol: Validation of Semi-Volatile Analysis by HPLC-MS/MS by EPA Method MS777

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owens, J; Koester, C

    The Environmental Protection Agency's (EPA) Region 5 Chicago Regional Laboratory (CRL) developed a method for the analysis of thiodiglycol, the breakdown product of the sulfur mustard HD, in water by high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS), titled Method EPA MS777 (hereafter referred to as EPA CRL SOP MS777). This draft standard operating procedure (SOP) was distributed to multiple EPA laboratories and to Lawrence Livermore National Laboratory, which was tasked to serve as a reference laboratory for EPA's Environmental Reference Laboratory Network (ERLN) and to develop and validate analytical procedures. The primary objective of this study was to verifymore » the analytical procedures described in MS777 for analysis of thiodiglycol in aqueous samples. The gathered data from this study will be used to: (1) demonstrate analytical method performance; (2) generate quality control acceptance criteria; and (3) revise the SOP to provide a validated method that would be available for use during a homeland security event. The data contained in this report will be compiled, by EPA CRL, with data generated by other EPA Regional laboratories so that performance metrics of Method EPA MS777 can be determined.« less

  16. 30 CFR 777.15 - Completeness.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Completeness. 777.15 Section 777.15 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR SURFACE COAL... CONTENT REQUIREMENTS FOR PERMIT APPLICATIONS § 777.15 Completeness. An application for a permit to conduct...

  17. 30 CFR 777.15 - Completeness.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 3 2011-07-01 2011-07-01 false Completeness. 777.15 Section 777.15 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR SURFACE COAL... CONTENT REQUIREMENTS FOR PERMIT APPLICATIONS § 777.15 Completeness. An application for a permit to conduct...

  18. 39 CFR 777.26 - Mobile homes.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Mobile homes. 777.26 Section 777.26 Postal Service... POLICIES Uniform Relocation Assistance § 777.26 Mobile homes. (a) Moving Expenses. Displaced persons who are occupants of mobile homes are eligible for moving expenses under § 777.23 subject to the following...

  19. 39 CFR 777.26 - Mobile homes.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 39 Postal Service 1 2013-07-01 2013-07-01 false Mobile homes. 777.26 Section 777.26 Postal Service... POLICIES Uniform Relocation Assistance § 777.26 Mobile homes. (a) Moving Expenses. Displaced persons who are occupants of mobile homes are eligible for moving expenses under § 777.23 subject to the following...

  20. 39 CFR 777.26 - Mobile homes.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 39 Postal Service 1 2011-07-01 2011-07-01 false Mobile homes. 777.26 Section 777.26 Postal Service... POLICIES Uniform Relocation Assistance § 777.26 Mobile homes. (a) Moving Expenses. Displaced persons who are occupants of mobile homes are eligible for moving expenses under § 777.23 subject to the following...

  1. 39 CFR 777.26 - Mobile homes.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 39 Postal Service 1 2012-07-01 2012-07-01 false Mobile homes. 777.26 Section 777.26 Postal Service... POLICIES Uniform Relocation Assistance § 777.26 Mobile homes. (a) Moving Expenses. Displaced persons who are occupants of mobile homes are eligible for moving expenses under § 777.23 subject to the following...

  2. 39 CFR 777.26 - Mobile homes.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 39 Postal Service 1 2014-07-01 2014-07-01 false Mobile homes. 777.26 Section 777.26 Postal Service... POLICIES Uniform Relocation Assistance § 777.26 Mobile homes. (a) Moving Expenses. Displaced persons who are occupants of mobile homes are eligible for moving expenses under § 777.23 subject to the following...

  3. 30 CFR 777.17 - Permit fees.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 3 2011-07-01 2011-07-01 false Permit fees. 777.17 Section 777.17 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR SURFACE COAL... CONTENT REQUIREMENTS FOR PERMIT APPLICATIONS § 777.17 Permit fees. An application for a surface coal...

  4. 30 CFR 777.17 - Permit fees.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Permit fees. 777.17 Section 777.17 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR SURFACE COAL... CONTENT REQUIREMENTS FOR PERMIT APPLICATIONS § 777.17 Permit fees. An application for a surface coal...

  5. 14 CFR 23.777 - Cockpit controls.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Cockpit controls. 23.777 Section 23.777... Cargo Accommodations § 23.777 Cockpit controls. Link to an amendment published at 76 FR 75757, December 2, 2011. (a) Each cockpit control must be located and (except where its function is obvious...

  6. 14 CFR 23.777 - Cockpit controls.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Cockpit controls. 23.777 Section 23.777... Cargo Accommodations § 23.777 Cockpit controls. (a) Each cockpit control must be located and (except... inadvertent operation. (b) The controls must be located and arranged so that the pilot, when seated, has full...

  7. 30 CFR 777.1 - Scope.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 3 2011-07-01 2011-07-01 false Scope. 777.1 Section 777.1 Mineral Resources... RECLAMATION OPERATIONS PERMITS AND COAL EXPLORATION SYSTEMS UNDER REGULATORY PROGRAMS GENERAL CONTENT... general content for permit applications under a State or Federal program. ...

  8. 30 CFR 777.1 - Scope.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Scope. 777.1 Section 777.1 Mineral Resources... RECLAMATION OPERATIONS PERMITS AND COAL EXPLORATION SYSTEMS UNDER REGULATORY PROGRAMS GENERAL CONTENT... general content for permit applications under a State or Federal program. ...

  9. 76 FR 2846 - Airworthiness Directives; The Boeing Company Model 777-200, -200LR, -300, and -300ER Series...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-18

    ... Building Ground Floor, Room W12-140, 1200 New Jersey Avenue, SE., Washington, DC 20590. Hand Delivery.... For service information identified in this proposed AD, contact Boeing Commercial Airplanes, Attention... Attention Service Bulletin 777-29-0032, dated August 9, 2007 (for Model 777-200, -200LR, -300, and -300ER...

  10. 30 CFR 777.11 - Format and contents.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Format and contents. 777.11 Section 777.11 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR SURFACE... GENERAL CONTENT REQUIREMENTS FOR PERMIT APPLICATIONS § 777.11 Format and contents. (a) An application...

  11. 30 CFR 777.11 - Format and contents.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 3 2011-07-01 2011-07-01 false Format and contents. 777.11 Section 777.11 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR SURFACE... GENERAL CONTENT REQUIREMENTS FOR PERMIT APPLICATIONS § 777.11 Format and contents. (a) An application...

  12. 39 CFR 777.51 - Acceptance of donations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Acceptance of donations. 777.51 Section 777.51... ACQUISITION POLICIES Donations § 777.51 Acceptance of donations. Nothing in these regulations shall prevent a person from making a gift or donation of real property or any part thereof, or any interest therein, or...

  13. 39 CFR 777.51 - Acceptance of donations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 39 Postal Service 1 2013-07-01 2013-07-01 false Acceptance of donations. 777.51 Section 777.51... ACQUISITION POLICIES Donations § 777.51 Acceptance of donations. Nothing in these regulations shall prevent a person from making a gift or donation of real property or any part thereof, or any interest therein, or...

  14. 39 CFR 777.51 - Acceptance of donations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 39 Postal Service 1 2012-07-01 2012-07-01 false Acceptance of donations. 777.51 Section 777.51... ACQUISITION POLICIES Donations § 777.51 Acceptance of donations. Nothing in these regulations shall prevent a person from making a gift or donation of real property or any part thereof, or any interest therein, or...

  15. 39 CFR 777.51 - Acceptance of donations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 39 Postal Service 1 2014-07-01 2014-07-01 false Acceptance of donations. 777.51 Section 777.51... ACQUISITION POLICIES Donations § 777.51 Acceptance of donations. Nothing in these regulations shall prevent a person from making a gift or donation of real property or any part thereof, or any interest therein, or...

  16. 39 CFR 777.51 - Acceptance of donations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 39 Postal Service 1 2011-07-01 2011-07-01 false Acceptance of donations. 777.51 Section 777.51... ACQUISITION POLICIES Donations § 777.51 Acceptance of donations. Nothing in these regulations shall prevent a person from making a gift or donation of real property or any part thereof, or any interest therein, or...

  17. 30 CFR 777.13 - Reporting of technical data.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 3 2011-07-01 2011-07-01 false Reporting of technical data. 777.13 Section 777.13 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR... PROGRAMS GENERAL CONTENT REQUIREMENTS FOR PERMIT APPLICATIONS § 777.13 Reporting of technical data. (a) All...

  18. 14 CFR 27.777 - Cockpit controls.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Cockpit controls. 27.777 Section 27.777... Cockpit controls. Cockpit controls must be— (a) Located to provide convenient operation and to prevent... there is full and unrestricted movement of each control without interference from the cockpit structure...

  19. 30 CFR 777.13 - Reporting of technical data.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... descriptions of the methodology used to collect and analyze the data. (b) Technical analyses shall be planned... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Reporting of technical data. 777.13 Section 777... PROGRAMS GENERAL CONTENT REQUIREMENTS FOR PERMIT APPLICATIONS § 777.13 Reporting of technical data. (a) All...

  20. 14 CFR 25.777 - Cockpit controls.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Cockpit controls. 25.777 Section 25.777... Cockpit controls. (a) Each cockpit control must be located to provide convenient operation and to prevent confusion and inadvertent operation. (b) The direction of movement of cockpit controls must meet the...

  1. 14 CFR 25.777 - Cockpit controls.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Cockpit controls. 25.777 Section 25.777... Cockpit controls. (a) Each cockpit control must be located to provide convenient operation and to prevent confusion and inadvertent operation. (b) The direction of movement of cockpit controls must meet the...

  2. VIEW OF 77710A REACTOR WING, LOOKING NORTHEAST,SHOWING LOADING DOOR TO ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF 777-10A REACTOR WING, LOOKING NORTHEAST,SHOWING LOADING DOOR TO THE PROCESS DEVELOPMENT PILE ROOM. BUILDING 305-A IN BACKGROUND ON LEFT - Physics Assembly Laboratory, Area A/M, Savannah River Site, Aiken, Aiken County, SC

  3. 23. AERIAL VIEW LOOKING SOUTHEAST AT THE PLUTONIUM OPERATION BUILDINGS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    23. AERIAL VIEW LOOKING SOUTHEAST AT THE PLUTONIUM OPERATION BUILDINGS 771, 776/777, AND 707. BUILDING 771, IN THE FOREGROUND, WAS BUILT IN 1952 TO HOUSE ALL PLUTONIUM OPERATIONS. BY 1956, BUILDING 771 WAS NO LONGER ADEQUATE FOR PRODUCTION DEMANDS. BUILDING 776/777, TO THE SOUTH OF BUILDING 771, WAS CONSTRUCTED TO HOUSE PLUTONIUM FABRICATION AND FOUNDRY OPERATIONS. PLUTONIUM RECOVERY REMAINED IN BUILDING 771. BY 1967, CONSTRUCTION ON BUILDING 707, TO THE SOUTH OF BUILDING 776/777, BEGAN AS PRODUCTION LEVELS CONTINUED TO EXPAND NECESSITATING THE NEED FOR ADDITIONAL PLUTONIUM FABRICATION SPACE (7/1/69). - Rocky Flats Plant, Bounded by Indiana Street & Routes 93, 128 & 72, Golden, Jefferson County, CO

  4. Laboratory Buildings.

    ERIC Educational Resources Information Center

    Barnett, Jonathan

    The need for flexibility in science research facilities is discussed, with emphasis on the effect of that need on the design of laboratories. The relationship of office space, bench space, and special equipment areas, and the location and distribution of piping and air conditioning, are considered particularly important. This building type study…

  5. 30 CFR 921.777 - General content requirements for permit applications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 3 2011-07-01 2011-07-01 false General content requirements for permit applications. 921.777 Section 921.777 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT... MASSACHUSETTS § 921.777 General content requirements for permit applications. Part 777 of this chapter, General...

  6. 30 CFR 912.777 - General content requirements for permit applications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false General content requirements for permit applications. 912.777 Section 912.777 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT... § 912.777 General content requirements for permit applications. Part 777 of this chapter, General...

  7. 30 CFR 941.777 - General content requirements for permit applications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false General content requirements for permit applications. 941.777 Section 941.777 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT... DAKOTA § 941.777 General content requirements for permit applications. Part 777 of this chapter, General...

  8. 30 CFR 937.777 - General content requirements for permit applications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 3 2011-07-01 2011-07-01 false General content requirements for permit applications. 937.777 Section 937.777 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT... § 937.777 General content requirements for permit applications. Part 777 of this chapter, General...

  9. 30 CFR 912.777 - General content requirements for permit applications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 3 2011-07-01 2011-07-01 false General content requirements for permit applications. 912.777 Section 912.777 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT... § 912.777 General content requirements for permit applications. Part 777 of this chapter, General...

  10. 30 CFR 942.777 - General content requirements for permit applications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 3 2011-07-01 2011-07-01 false General content requirements for permit applications. 942.777 Section 942.777 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT... § 942.777 General content requirements for permit applications. Part 777 of this chapter, General...

  11. 30 CFR 933.777 - General content requirements for permit applications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false General content requirements for permit applications. 933.777 Section 933.777 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT... CAROLINA § 933.777 General content requirements for permit applications. Part 777 of this chapter, General...

  12. 30 CFR 922.777 - General content requirements for permit applications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 3 2011-07-01 2011-07-01 false General content requirements for permit applications. 922.777 Section 922.777 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT... § 922.777 General content requirements for permit applications. Part 777 of this chapter, General...

  13. 30 CFR 942.777 - General content requirements for permit applications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false General content requirements for permit applications. 942.777 Section 942.777 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT... § 942.777 General content requirements for permit applications. Part 777 of this chapter, General...

  14. 30 CFR 910.777 - General content requirements for permit applications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false General content requirements for permit applications. 910.777 Section 910.777 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT... § 910.777 General content requirements for permit applications. Part 777 of this chapter, General...

  15. 30 CFR 937.777 - General content requirements for permit applications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false General content requirements for permit applications. 937.777 Section 937.777 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT... § 937.777 General content requirements for permit applications. Part 777 of this chapter, General...

  16. 30 CFR 939.777 - General content requirements for permit applications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false General content requirements for permit applications. 939.777 Section 939.777 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT... ISLAND § 939.777 General content requirements for permit applications. Part 777 of this chapter, General...

  17. 30 CFR 910.777 - General content requirements for permit applications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 3 2011-07-01 2011-07-01 false General content requirements for permit applications. 910.777 Section 910.777 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT... § 910.777 General content requirements for permit applications. Part 777 of this chapter, General...

  18. 30 CFR 922.777 - General content requirements for permit applications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false General content requirements for permit applications. 922.777 Section 922.777 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT... § 922.777 General content requirements for permit applications. Part 777 of this chapter, General...

  19. 30 CFR 941.777 - General content requirements for permit applications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 3 2011-07-01 2011-07-01 false General content requirements for permit applications. 941.777 Section 941.777 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT... DAKOTA § 941.777 General content requirements for permit applications. Part 777 of this chapter, General...

  20. 30 CFR 947.777 - General content requirements for permit applications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 3 2011-07-01 2011-07-01 false General content requirements for permit applications. 947.777 Section 947.777 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT... § 947.777 General content requirements for permit applications. Part 777 of this chapter, General...

  1. 30 CFR 947.777 - General content requirements for permit applications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false General content requirements for permit applications. 947.777 Section 947.777 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT... § 947.777 General content requirements for permit applications. Part 777 of this chapter, General...

  2. 30 CFR 921.777 - General content requirements for permit applications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false General content requirements for permit applications. 921.777 Section 921.777 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT... MASSACHUSETTS § 921.777 General content requirements for permit applications. Part 777 of this chapter, General...

  3. 30 CFR 939.777 - General content requirements for permit applications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 3 2011-07-01 2011-07-01 false General content requirements for permit applications. 939.777 Section 939.777 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT... ISLAND § 939.777 General content requirements for permit applications. Part 777 of this chapter, General...

  4. 30 CFR 933.777 - General content requirements for permit applications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 3 2011-07-01 2011-07-01 false General content requirements for permit applications. 933.777 Section 933.777 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT... CAROLINA § 933.777 General content requirements for permit applications. Part 777 of this chapter, General...

  5. 30 CFR 777.14 - Maps and plans: General requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Maps and plans: General requirements. 777.14 Section 777.14 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE... REGULATORY PROGRAMS GENERAL CONTENT REQUIREMENTS FOR PERMIT APPLICATIONS § 777.14 Maps and plans: General...

  6. 30 CFR 777.14 - Maps and plans: General requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 3 2011-07-01 2011-07-01 false Maps and plans: General requirements. 777.14 Section 777.14 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE... REGULATORY PROGRAMS GENERAL CONTENT REQUIREMENTS FOR PERMIT APPLICATIONS § 777.14 Maps and plans: General...

  7. 10. Floor Layout of Thermal Hydraulics Laboratory, from The Thermal ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Floor Layout of Thermal Hydraulics Laboratory, from The Thermal Hydraulics Laboratory at Hanford. General Electric Company, Hanford Atomic Products Operation, Richland, Washington, 1961. - D-Reactor Complex, Deaeration Plant-Refrigeration Buildings, Area 100-D, Richland, Benton County, WA

  8. 30 CFR 777.11 - Format and contents.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 3 2013-07-01 2013-07-01 false Format and contents. 777.11 Section 777.11 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR SURFACE COAL MINING AND RECLAMATION OPERATIONS PERMITS AND COAL EXPLORATION SYSTEMS UNDER REGULATORY PROGRAMS GENERAL CONTENT REQUIREMENTS FOR PERMIT...

  9. 10. Interior view of control room in Components Test Laboratory ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Interior view of control room in Components Test Laboratory (T-27), looking east. The control room is located in the center of the building and abuts the Test Cell 8, 9, and 10 and equipment room wings. Photograph shows upgraded instrumentation, piping, and technological modifications installed in 1997-99 to accommodate component testing requirements for the Atlas V missile. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  10. Building capacity in laboratory medicine in Africa by increasing physician involvement: a laboratory medicine course for clinicians.

    PubMed

    Guarner, Jeannette; Amukele, Timothy; Mehari, Meheretu; Gemechu, Tufa; Woldeamanuel, Yimtubezinash; Winkler, Anne M; Asrat, Daniel; Wilson, Michael L; del Rio, Carlos

    2015-03-01

    To describe a 4-day laboratory medicine course for clinicians given at Addis Ababa University, Ethiopia, designed to improve the use of laboratory-based diagnoses. Each day was dedicated to one of the following topics: hematology, blood bank/transfusion medicine and coagulation, chemistry, and microbiology. The course included lectures, case-based learning, laboratory tours, and interactive computer case-based homework. The same 12-question knowledge quiz was given before and after the course. Twenty-eight participants took the quiz before and 21 after completing the course. The average score was 5.28 (range, 2-10) for the initial quiz and 8.09 (range, 4-11) for the second quiz (P = .0001). Two of 12 and 8 of 12 questions were answered correctly by more than 60% of trainees on the initial and second quiz, respectively. Knowledge and awareness of the role of the laboratory increased after participation in the course. Understanding of laboratory medicine principles by clinicians will likely improve use of laboratory services and build capacity in Africa. Copyright© by the American Society for Clinical Pathology.

  11. VIEW OF BUILDING 778 LOOKING WESTSOUTHWEST. BUILDING 778 HOUSED LAUNDRY ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF BUILDING 778 LOOKING WEST-SOUTHWEST. BUILDING 778 HOUSED LAUNDRY FACILITIES, SHOWERS, LOCKER ROOMS, SANITARY FACILITIES, AN ELECTRIC SHOP, MACHINE SHOP, SHEET METAL SHOP, AND INERT GAS STORAGE. (12/7/90) - Rocky Flats Plant, Laundry Facility, Northeast quad of Plant between buildings 776/777 & 707, Golden, Jefferson County, CO

  12. 23 CFR 777.1 - Purpose.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... NATURAL HABITAT § 777.1 Purpose. To provide policy and procedures for the evaluation and mitigation of adverse environmental impacts to wetlands and natural habitat resulting from Federal-aid projects funded...

  13. 23 CFR 777.1 - Purpose.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... NATURAL HABITAT § 777.1 Purpose. To provide policy and procedures for the evaluation and mitigation of adverse environmental impacts to wetlands and natural habitat resulting from Federal-aid projects funded...

  14. 23 CFR 777.1 - Purpose.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... NATURAL HABITAT § 777.1 Purpose. To provide policy and procedures for the evaluation and mitigation of adverse environmental impacts to wetlands and natural habitat resulting from Federal-aid projects funded...

  15. 23 CFR 777.1 - Purpose.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... NATURAL HABITAT § 777.1 Purpose. To provide policy and procedures for the evaluation and mitigation of adverse environmental impacts to wetlands and natural habitat resulting from Federal-aid projects funded...

  16. 23 CFR 777.1 - Purpose.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... NATURAL HABITAT § 777.1 Purpose. To provide policy and procedures for the evaluation and mitigation of adverse environmental impacts to wetlands and natural habitat resulting from Federal-aid projects funded...

  17. SAFETY IN THE DESIGN OF SCIENCE LABORATORIES AND BUILDING CODES.

    ERIC Educational Resources Information Center

    HOROWITZ, HAROLD

    THE DESIGN OF COLLEGE AND UNIVERSITY BUILDINGS USED FOR SCIENTIFIC RESEARCH AND EDUCATION IS DISCUSSED IN TERMS OF LABORATORY SAFETY AND BUILDING CODES AND REGULATIONS. MAJOR TOPIC AREAS ARE--(1) SAFETY RELATED DESIGN FEATURES OF SCIENCE LABORATORIES, (2) LABORATORY SAFETY AND BUILDING CODES, AND (3) EVIDENCE OF UNSAFE DESIGN. EXAMPLES EMPHASIZE…

  18. 2. Exterior view of Systems Integration Laboratory Building (T28), looking ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Exterior view of Systems Integration Laboratory Building (T-28), looking southwest. The low-lying concrete Signal Transfer Building (T-28A) is located in the immediate foreground. - Air Force Plant PJKS, Systems Integration Laboratory, Systems Integration Laboratory Building, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  19. 75 FR 78594 - Airworthiness Directives; The Boeing Company Model 777-200 Series Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-16

    ... which a T/R is installed with a design change known as ``Commonality T/R,'' which is common to Model 777... Airworthiness Directives; The Boeing Company Model 777-200 Series Airplanes AGENCY: Federal Aviation... certain Model 777-200 series airplanes. This AD requires installing a new insulation blanket on the latch...

  20. Challenges and payoff of composites in transport aircraft: 777 empennage and future applications

    NASA Technical Reports Server (NTRS)

    Quinlivan, John

    1993-01-01

    The Boeing 777 is the first of a new family of wide body airplanes. The new large twin is sized to accommodate 360 to 390 passengers in typical two-class configurations and planned growth beyond that. The 777 offers airlines three engine options, extremely attractive operating costs, and compatibility with existing airport gates and taxiways. The 777 has a wingspan of nearly 197 feet and is offered with a wing-tip folding mechanism that will reduce the span to 156 feet. Extensive use of advance composite is included in the 777. The application range from fiberglass fairing to primary structures. The 777 empennage includes vertical fin and a horizontal stabilizer. The material used for the empennage is a new, toughened epoxy materials. The material provides outstanding resistance to impact damage.

  1. 9. Exterior view, Test Cell 7, Systems Integration Laboratory Building ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. Exterior view, Test Cell 7, Systems Integration Laboratory Building (T-28), looking southwest. The enclosure discussed in CO-88-B-8 is at the right. - Air Force Plant PJKS, Systems Integration Laboratory, Systems Integration Laboratory Building, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  2. 30 CFR 937.777 - General content requirements for permit applications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 3 2013-07-01 2013-07-01 false General content requirements for permit applications. 937.777 Section 937.777 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR PROGRAMS FOR THE CONDUCT OF SURFACE MINING OPERATIONS WITHIN EACH STATE OREGON...

  3. 30 CFR 937.777 - General content requirements for permit applications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 3 2014-07-01 2014-07-01 false General content requirements for permit applications. 937.777 Section 937.777 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR PROGRAMS FOR THE CONDUCT OF SURFACE MINING OPERATIONS WITHIN EACH STATE OREGON...

  4. Building a Laboratory-Scale Biogas Plant and Verifying its Functionality

    NASA Astrophysics Data System (ADS)

    Boleman, Tomáš; Fiala, Jozef; Blinová, Lenka; Gerulová, Kristína

    2011-01-01

    The paper deals with the process of building a laboratory-scale biogas plant and verifying its functionality. The laboratory-scale prototype was constructed in the Department of Safety and Environmental Engineering at the Faculty of Materials Science and Technology in Trnava, of the Slovak University of Technology. The Department has already built a solar laboratory to promote and utilise solar energy, and designed SETUR hydro engine. The laboratory is the next step in the Department's activities in the field of renewable energy sources and biomass. The Department is also involved in the European Union project, where the goal is to upgrade all existed renewable energy sources used in the Department.

  5. 4. Exterior view of Systems Integration Laboratory Building (T28), looking ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. Exterior view of Systems Integration Laboratory Building (T-28), looking northwest. - Air Force Plant PJKS, Systems Integration Laboratory, Systems Integration Laboratory Building, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  6. 3. Exterior view of Systems Integration Laboratory Building (T28), looking ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. Exterior view of Systems Integration Laboratory Building (T-28), looking southeast. - Air Force Plant PJKS, Systems Integration Laboratory, Systems Integration Laboratory Building, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  7. 5. INTERIOR OF BUILDING 313, SHOWING LABORATORY. VIEW TO SOUTHWEST. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. INTERIOR OF BUILDING 313, SHOWING LABORATORY. VIEW TO SOUTHWEST. - Rocky Mountain Arsenal, Laboratory Building, 510 feet South of December Seventh Avenue; 175 feet East of D Street, Commerce City, Adams County, CO

  8. 3. INTERIOR OF BUILDING 313, SHOWING LABORATORY. VIEW TO SOUTHEAST. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. INTERIOR OF BUILDING 313, SHOWING LABORATORY. VIEW TO SOUTHEAST. - Rocky Mountain Arsenal, Laboratory Building, 510 feet South of December Seventh Avenue; 175 feet East of D Street, Commerce City, Adams County, CO

  9. 7. INTERIOR OF BUILDING 313, SHOWING LABORATORY. VIEW TO NORTHEAST. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. INTERIOR OF BUILDING 313, SHOWING LABORATORY. VIEW TO NORTHEAST. - Rocky Mountain Arsenal, Laboratory Building, 510 feet South of December Seventh Avenue; 175 feet East of D Street, Commerce City, Adams County, CO

  10. 4. INTERIOR OF BUILDING 313, SHOWING LABORATORY. VIEW TO EAST. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. INTERIOR OF BUILDING 313, SHOWING LABORATORY. VIEW TO EAST. - Rocky Mountain Arsenal, Laboratory Building, 510 feet South of December Seventh Avenue; 175 feet East of D Street, Commerce City, Adams County, CO

  11. 6. INTERIOR OF BUILDING 313, SHOWING LABORATORY. VIEW TO NORTHWEST. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. INTERIOR OF BUILDING 313, SHOWING LABORATORY. VIEW TO NORTHWEST. - Rocky Mountain Arsenal, Laboratory Building, 510 feet South of December Seventh Avenue; 175 feet East of D Street, Commerce City, Adams County, CO

  12. 23 CFR 777.11 - Other considerations.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... IMPACTS TO WETLANDS AND NATURAL HABITAT § 777.11 Other considerations. (a) The development of measures proposed to mitigate impacts to wetlands or natural habitats shall include consultation with appropriate... or natural habitats absent sufficient assurances, such as, but not limited to, deed restrictions, fee...

  13. 23 CFR 777.11 - Other considerations.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... IMPACTS TO WETLANDS AND NATURAL HABITAT § 777.11 Other considerations. (a) The development of measures proposed to mitigate impacts to wetlands or natural habitats shall include consultation with appropriate... or natural habitats absent sufficient assurances, such as, but not limited to, deed restrictions, fee...

  14. 23 CFR 777.11 - Other considerations.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... IMPACTS TO WETLANDS AND NATURAL HABITAT § 777.11 Other considerations. (a) The development of measures proposed to mitigate impacts to wetlands or natural habitats shall include consultation with appropriate... or natural habitats absent sufficient assurances, such as, but not limited to, deed restrictions, fee...

  15. 23 CFR 777.11 - Other considerations.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... IMPACTS TO WETLANDS AND NATURAL HABITAT § 777.11 Other considerations. (a) The development of measures proposed to mitigate impacts to wetlands or natural habitats shall include consultation with appropriate... or natural habitats absent sufficient assurances, such as, but not limited to, deed restrictions, fee...

  16. Building a Low-Cost Gross Anatomy Laboratory: A Big Step for a Small University

    ERIC Educational Resources Information Center

    Goldman, Evan

    2010-01-01

    This article illustrates details of the planning, building, and improvement phases of a cost-efficient, full-dissection gross anatomy laboratory on a campus of an historically design-centric university. Special considerations were given throughout the project to the nature of hosting cadavers in a building shared amongst all undergraduate majors.…

  17. 23 CFR 777.5 - Federal participation.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... IMPACTS TO WETLANDS AND NATURAL HABITAT § 777.5 Federal participation. (a) Those measures which the FHWA... and natural habitats are eligible for Federal participation where the impacts are the result of..., monitoring, and establishment of wetlands and natural habitat mitigation projects, and acquisition of land or...

  18. 23 CFR 777.5 - Federal participation.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... IMPACTS TO WETLANDS AND NATURAL HABITAT § 777.5 Federal participation. (a) Those measures which the FHWA... and natural habitats are eligible for Federal participation where the impacts are the result of..., monitoring, and establishment of wetlands and natural habitat mitigation projects, and acquisition of land or...

  19. 23 CFR 777.5 - Federal participation.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... IMPACTS TO WETLANDS AND NATURAL HABITAT § 777.5 Federal participation. (a) Those measures which the FHWA... and natural habitats are eligible for Federal participation where the impacts are the result of..., monitoring, and establishment of wetlands and natural habitat mitigation projects, and acquisition of land or...

  20. 23 CFR 777.5 - Federal participation.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... IMPACTS TO WETLANDS AND NATURAL HABITAT § 777.5 Federal participation. (a) Those measures which the FHWA... and natural habitats are eligible for Federal participation where the impacts are the result of..., monitoring, and establishment of wetlands and natural habitat mitigation projects, and acquisition of land or...

  1. 23 CFR 777.5 - Federal participation.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... IMPACTS TO WETLANDS AND NATURAL HABITAT § 777.5 Federal participation. (a) Those measures which the FHWA... and natural habitats are eligible for Federal participation where the impacts are the result of..., monitoring, and establishment of wetlands and natural habitat mitigation projects, and acquisition of land or...

  2. 75 FR 39811 - Airworthiness Directives; The Boeing Company Model 777 Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-13

    ... Service Bulletin 777-57A0064, dated March 26, 2009, it is not necessary to perform the torque check on the... instructions in Boeing Alert Service Bulletin 777-57A0064, dated March 26, 2009, a torque check is redundant... are less than those for the torque check. Boeing notes that it plans to issue a new revision to this...

  3. Full-length genome sequences of porcine epidemic diarrhoea virus strain CV777; Use of NGS to analyse genomic and sub-genomic RNAs

    PubMed Central

    Rasmussen, Thomas Bruun; Boniotti, Maria Beatrice; Papetti, Alice; Grasland, Béatrice; Frossard, Jean-Pierre; Dastjerdi, Akbar; Hulst, Marcel; Hanke, Dennis; Pohlmann, Anne; Blome, Sandra; van der Poel, Wim H. M.; Steinbach, Falko; Blanchard, Yannick; Lavazza, Antonio; Bøtner, Anette

    2018-01-01

    Porcine epidemic diarrhoea virus, strain CV777, was initially characterized in 1978 as the causative agent of a disease first identified in the UK in 1971. This coronavirus has been widely distributed among laboratories and has been passaged both within pigs and in cell culture. To determine the variability between different stocks of the PEDV strain CV777, sequencing of the full-length genome (ca. 28kb) has been performed in 6 different laboratories, using different protocols. Not surprisingly, each of the different full genome sequences were distinct from each other and from the reference sequence (Accession number AF353511) but they are >99% identical. Unique and shared differences between sequences were identified. The coding region for the surface-exposed spike protein showed the highest proportion of variability including both point mutations and small deletions. The predicted expression of the ORF3 gene product was more dramatically affected in three different variants of this virus through either loss of the initiation codon or gain of a premature termination codon. The genome of one isolate had a substantially rearranged 5´-terminal sequence. This rearrangement was validated through the analysis of sub-genomic mRNAs from infected cells. It is clearly important to know the features of the specific sample of CV777 being used for experimental studies. PMID:29494671

  4. A&M. Technical service laboratory in administration building (TAN602). Floor plan, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A&M. Technical service laboratory in administration building (TAN-602). Floor plan, reception desk, door and finish schedules. Ralph M. Parsons 1480-12-ANP/GE-3-602-A-1. INEEL index code no. 033-0602-00-693-107488 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  5. The BOEING 777 - concurrent engineering and digital pre-assembly

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abarbanel, B.

    The processes created on the 777 for checking designs were called {open_quotes}digital pre-assembly{close_quotes}. Using FlyThru(tm), a spin-off of a Boeing advanced computing research project, engineers were able to view up to 1500 models (15000 solids) in 3d traversing that data at high speed. FlyThru(tm) was rapidly deployed in 1991 to meet the needs of the 777 for large scale product visualization and verification. The digital pre-assembly process has bad fantastic results. The 777 has had far fewer assembly and systems problems compared to previous airplane programs. Today, FlyThru(tm) is installed on hundreds of workstations on almost every airplane program, andmore » is being used on Space Station, F22, AWACS, and other defense projects. It`s applications have gone far beyond just design review. In many ways, FlyThru is a Data Warehouse supported by advanced tools for analysis. It is today being integrated with Knowledge Based Engineering geometry generation tools.« less

  6. Temporary Laboratory Office in Huntsville Industrial Center Building

    NASA Technical Reports Server (NTRS)

    1964-01-01

    Temporary quarters in the Huntsville Industrial Center (HIC) building located in downtown Huntsville, Alabama, as Marshall Space Flight Center (MSFC) grew. This image shows drafting specialists from the Propulsion and Vehicle Engineering Laboratory at work in the HIC building.

  7. Flight Research Building at the Aircraft Engine Research Laboratory

    NASA Image and Video Library

    1942-09-21

    The Flight Research Building at the National Advisory Committee for Aeronautics (NACA) Aircraft Engine Research Laboratory is a 272- by 150-foot hangar with an internal height up to 90 feet. The hangar’s massive 37.5-foot-tall and 250-foot-long doors can be opened in sections to suit different size aircraft. The hangar has sheltered a diverse fleet of aircraft over the decades. These have ranged from World War II bombers to Cessna trainers and from supersonic fighter jets to a DC–9 airliner. At the time of this September 1942 photograph, however, the hangar was being used as an office building during the construction of the laboratory. In December of 1941, the Flight Research Building became the lab’s first functional building. Temporary offices were built inside the structure to house the staff while the other buildings were completed. The hangar offices were used for an entire year before being removed in early 1943. It was only then that the laboratory acquired its first aircraft, pilots and flight mechanics. The temporary one-story offices can be seen in this photograph inside the large sliding doors. Also note the vertical lift gate below the NACA logo. The gate was installed so that the tails of larger aircraft could pass into the hangar. The white Farm House that served as the Administration Building during construction can be seen in the distance to the left of the hangar.

  8. Fire safety evaluation system for NASA office/laboratory buildings

    NASA Astrophysics Data System (ADS)

    Nelson, H. E.

    1986-11-01

    A fire safety evaluation system for office/laboratory buildings is developed. The system is a life safety grading system. The system scores building construction, hazardous areas, vertical openings, sprinklers, detectors, alarms, interior finish, smoke control, exit systems, compartmentation, and emergency preparedness.

  9. PBF Reactor Building (PER620). Cubicle 10 detail. Camera facing west ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PBF Reactor Building (PER-620). Cubicle 10 detail. Camera facing west toward brick shield wall. Valve stems against wall penetrate through east wall of cubicle. Photographer: John Capek. Date: August 19, 1970. INEEL negative no. 70-3469 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID

  10. 23 CFR 777.9 - Mitigation of impacts.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... IMPACTS TO WETLANDS AND NATURAL HABITAT § 777.9 Mitigation of impacts. (a) Actions eligible for Federal... wetlands or natural habitats. The following actions qualify for Federal-aid highway funding: (1) Avoidance and minimization of impacts to wetlands or natural habitats through realignment and special design...

  11. 23 CFR 777.9 - Mitigation of impacts.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... IMPACTS TO WETLANDS AND NATURAL HABITAT § 777.9 Mitigation of impacts. (a) Actions eligible for Federal... wetlands or natural habitats. The following actions qualify for Federal-aid highway funding: (1) Avoidance and minimization of impacts to wetlands or natural habitats through realignment and special design...

  12. 23 CFR 777.9 - Mitigation of impacts.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... IMPACTS TO WETLANDS AND NATURAL HABITAT § 777.9 Mitigation of impacts. (a) Actions eligible for Federal... wetlands or natural habitats. The following actions qualify for Federal-aid highway funding: (1) Avoidance and minimization of impacts to wetlands or natural habitats through realignment and special design...

  13. 5. BUILDING NO. 404, THERMO CHEMISTRY LABORATORY, LOOKING NORTHWEST AT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. BUILDING NO. 404, THERMO CHEMISTRY LABORATORY, LOOKING NORTHWEST AT SOUTH SIDE OF BUILDING. BUILDING NO. 403 IN BACKGROUND RIGHT. - Picatinny Arsenal, 400 Area, Gun Bag Loading District, State Route 15 near I-80, Dover, Morris County, NJ

  14. 10. SITE BUILDING 002 SCANNER BUILDING LOOKING AT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. SITE BUILDING 002 - SCANNER BUILDING - LOOKING AT SOUTHWEST CORNER "B" FACE AND "C" FACE ON WEST AND EVAPORATIVE COOLING TOWER AT NORTH. VIEW IS LOOKING NORTH 45° EAST. - Cape Cod Air Station, Technical Facility-Scanner Building & Power Plant, Massachusetts Military Reservation, Sandwich, Barnstable County, MA

  15. Crew Systems Laboratory/Building 7. Historical Documentation

    NASA Technical Reports Server (NTRS)

    Slovinac, Patricia

    2011-01-01

    Building 7 is managed by the Crew and Thermal Systems Division of the JSC Engineering Directorate. Originally named the Life Systems Laboratory, it contained five major test facilities: two advanced environmental control laboratories and three human-rated vacuum chambers (8 , 11 , and the 20 ). These facilities supported flight crew familiarization and the testing and evaluation of hardware used in the early manned spaceflight programs, including Gemini, Apollo, and the ASTP.

  16. Biosafety and Biosecurity: A Relative Risk-Based Framework for Safer, More Secure, and Sustainable Laboratory Capacity Building.

    PubMed

    Dickmann, Petra; Sheeley, Heather; Lightfoot, Nigel

    2015-01-01

    Laboratory capacity building is characterized by a paradox between endemicity and resources: countries with high endemicity of pathogenic agents often have low and intermittent resources (water, electricity) and capacities (laboratories, trained staff, adequate regulations). Meanwhile, countries with low endemicity of pathogenic agents often have high-containment facilities with costly infrastructure and maintenance governed by regulations. The common practice of exporting high biocontainment facilities and standards is not sustainable and concerns about biosafety and biosecurity require careful consideration. A group at Chatham House developed a draft conceptual framework for safer, more secure, and sustainable laboratory capacity building. The draft generic framework is guided by the phrase "LOCAL - PEOPLE - MAKE SENSE" that represents three major principles: capacity building according to local needs (local) with an emphasis on relationship and trust building (people) and continuous outcome and impact measurement (make sense). This draft generic framework can serve as a blueprint for international policy decision-making on improving biosafety and biosecurity in laboratory capacity building, but requires more testing and detailing development.

  17. PBF Reactor Building (PER620). Cubicle 10 area in basement. Highdensity ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PBF Reactor Building (PER-620). Cubicle 10 area in basement. High-density shielding bricks will protect personnel from radiation coming from in-pile-tube coolant and blowdown tank. Photographer: John Capek. Date: January 26, 1970. INEEL negative no. 70-348 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID

  18. 30 CFR 795.10 - Qualified laboratories.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 3 2011-07-01 2011-07-01 false Qualified laboratories. 795.10 Section 795.10... laboratories. (a) Basic qualifications. To be designated a qualified laboratory, a firm shall demonstrate that... necessary field samples and making hydrologic field measurements and analytical laboratory determinations by...

  19. Airport Pavement Design For The Boeing 777 Airplane

    DOT National Transportation Integrated Search

    1995-10-22

    The purpose of this advisory circular is to provide thickness design standards : for pavements intended to serve the Boeing 777 airplane. A new method of design : based on layered elastic analysis has been developed to calculate design : thickness fo...

  20. 1. Exterior view of Systems Integration Laboratory Building (T28), looking ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Exterior view of Systems Integration Laboratory Building (T-28), looking northeast. The taller of the two gantries on the left houses Test Cell 6 (fuel), while the shorter gantry on the right houses Test Cell 7 (oxidizer). This structure serves as the functional center of the Systems Integration Laboratory complex for testing, handling, and storage of the Titan II's hydrazine - and nitrogen tetroxide-based fuel system propellants. - Air Force Plant PJKS, Systems Integration Laboratory, Systems Integration Laboratory Building, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  1. 18. VIEW OF THE SECOND FLOOR OF BUILDING 707. AIR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. VIEW OF THE SECOND FLOOR OF BUILDING 707. AIR EXHAUST FANS ARE USED TO MAINTAIN PRESSURE DIFFERENTIALS WITHIN THE BUILDING. (5/70) - Rocky Flats Plant, Plutonium Manufacturing Facility, North-central section of Plant, just south of Building 776/777, Golden, Jefferson County, CO

  2. 4. BUILDING NO. 404, THERMO CHEMISTRY LABORATORY, LOOKING SOUTHEAST AT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. BUILDING NO. 404, THERMO CHEMISTRY LABORATORY, LOOKING SOUTHEAST AT SOUTH AND WEST SIDES OF BUILDING. ORIGINALLY USED AS A STOREHOUSE. - Picatinny Arsenal, 400 Area, Gun Bag Loading District, State Route 15 near I-80, Dover, Morris County, NJ

  3. PBF Reactor Building (PER620). Cubicle 10. Camera facing southeast. Loop ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PBF Reactor Building (PER-620). Cubicle 10. Camera facing southeast. Loop pressurizer on right. Other equipment includes loop strained, control valves, loop piping, pressurizer interchanger, and cleanup system cooler. High-density shielding brick walls. Photographer: Kirsh. Date: November 2, 1970. INEEL negative no. 70-4908 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID

  4. 10. Building 105, Facilities Engineering Building, 1830, interior, air condition ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Building 105, Facilities Engineering Building, 1830, interior, air condition repair shop, S end of building, looking N. - Watervliet Arsenal, Building 105, South Broadway, on Hudson River, Watervliet, Albany County, NY

  5. Toward a virtual building laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klems, J.H.; Finlayson, E.U.; Olsen, T.H.

    1999-03-01

    In order to achieve in a timely manner the large energy and dollar savings technically possible through improvements in building energy efficiency, it will be necessary to solve the problem of design failure risk. The most economical method of doing this would be to learn to calculate building performance with sufficient detail, accuracy and reliability to avoid design failure. Existing building simulation models (BSM) are a large step in this direction, but are still not capable of this level of modeling. Developments in computational fluid dynamics (CFD) techniques now allow one to construct a road map from present BSM's tomore » a complete building physical model. The most useful first step is a building interior model (BIM) that would allow prediction of local conditions affecting occupant health and comfort. To provide reliable prediction a BIM must incorporate the correct physical boundary conditions on a building interior. Doing so raises a number of specific technical problems and research questions. The solution of these within a context useful for building research and design is not likely to result from other research on CFD, which is directed toward the solution of different types of problems. A six-step plan for incorporating the correct boundary conditions within the context of the model problem of a large atrium has been outlined. A promising strategy for constructing a BIM is the overset grid technique for representing a building space in a CFD calculation. This technique promises to adapt well to building design and allows a step-by-step approach. A state-of-the-art CFD computer code using this technique has been adapted to the problem and can form the departure point for this research.« less

  6. Experimental Bleaching of a Reef-Building Coral Using a Simplified Recirculating Laboratory Exposure System

    EPA Science Inventory

    Determining stressor-response relationships in reef building corals is a critical need for researchers because of global declines in coral reef ecosystems. A simplified recirculating coral exposure system for laboratory testing of a diversity of species and morphologies of reef b...

  7. 46 CFR 160.010-10 - Independent laboratory.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Independent laboratory. 160.010-10 Section 160.010-10... laboratory. (a) The approval and production tests in this subpart must be conducted by an independent laboratory accepted by the Coast Guard under subpart 159.010 of this chapter. (b) [Reserved] ...

  8. 46 CFR 160.010-10 - Independent laboratory.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Independent laboratory. 160.010-10 Section 160.010-10... laboratory. (a) The approval and production tests in this subpart must be conducted by an independent laboratory accepted by the Coast Guard under subpart 159.010 of this chapter. (b) [Reserved] ...

  9. A virtual laboratory for the simulation of sustainable energy systems in a low energy building: A case study

    NASA Astrophysics Data System (ADS)

    Breen, M.; O'Donovan, A.; Murphy, M. D.; Delaney, F.; Hill, M.; Sullivan, P. D. O.

    2016-03-01

    The aim of this paper was to develop a virtual laboratory simulation platform of the National Building Retrofit Test-bed at the Cork Institute of Technology, Ireland. The building in question is a low-energy retrofit which is provided with electricity by renewable systems including photovoltaics and wind. It can be thought of as a living laboratory, as a number of internal and external building factors are recorded at regular intervals during human occupation. The analysis carried out in this paper demonstrated that, for the period from April to September 2015, the electricity provided by the renewable systems did not consistently match the building’s electricity requirements due to differing load profiles. It was concluded that the use of load shifting techniques may help to increase the percentage of renewable energy utilisation.

  10. 15. VIEW OF LABORATORY EQUIPMENT IN THE BUILDING 771 ANALYTICAL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. VIEW OF LABORATORY EQUIPMENT IN THE BUILDING 771 ANALYTICAL LABORATORY. THE LAB ANALYZED SAMPLES FOR PLUTONIUM, AMERICIUM, URANIUM, NEPTUNIUM, AND OTHER RADIOACTIVE ISOTOPES. (9/25/62) - Rocky Flats Plant, Plutonium Recovery & Fabrication Facility, North-central section of plant, Golden, Jefferson County, CO

  11. VIEW OF THE INTERIOR OF BUILDING 125, THE STANDARDS LABORATORY. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF THE INTERIOR OF BUILDING 125, THE STANDARDS LABORATORY. THE PRIMARY FUNCTION OF THE STANDARDS LABORATORY WAS TO ENSURE AND IMPLEMENT A SYSTEM OF QUALITY CONTROL FOR INCOMING MATERIALS USED IN MANUFACTURING PROCESSES. SEVERAL ENGINEERING CONTROLS WERE USED TO ASSURE ACCURACY OF THE CALIBRATION PROCESSES INCLUDING: FLEX-FREE GRANITE TABLES, AIR LOCKED DOORS, TEMPERATURE CONTROLS, AND A SUPER-CLEAN ENVIRONMENT - Rocky Flats Plant, Standards Laboratory, Immediately north of 215A water tower & adjacent to Third Street, Golden, Jefferson County, CO

  12. 39 CFR 777.22 - Relocation assistance advisory services.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Relocation assistance advisory services. 777.22... persons. (b) Relocation Information. The Postal Service must contact each displaced person to provide an... Provided. The advisory program shall include such services as may be necessary or appropriate to: (1...

  13. Photocopy of drawing (original drawing of Photographic Laboratory Building in ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of drawing (original drawing of Photographic Laboratory Building in possession of MacDill Air Force Base, Civil Engineering, Tampa, Florida; 1939 architectural drawings by Construction Division, Office of the Quartermaster General) PLANS - MacDill Air Force Base, Photographic Laboratory, 7718 Hanger Loop Drive, Tampa, Hillsborough County, FL

  14. Photocopy of drawing (original drawing of Photographic Laboratory Building in ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of drawing (original drawing of Photographic Laboratory Building in possession of MacDill Air Force Base, Civil Engineering, Tampa, Florida; 1939 architectural drawings by Construction Division, Office of the Quartermaster General) MAIN ENTRANCE DETAILS - MacDill Air Force Base, Photographic Laboratory, 7718 Hanger Loop Drive, Tampa, Hillsborough County, FL

  15. Building Cross-Country Networks for Laboratory Capacity and Improvement.

    PubMed

    Schneidman, Miriam; Matu, Martin; Nkengasong, John; Githui, Willie; Kalyesubula-Kibuuka, Simeon; Silva, Kelly Araujo

    2018-03-01

    Laboratory networks are vital to well-functioning public health systems and disease control efforts. Cross-country laboratory networks play a critical role in supporting epidemiologic surveillance, accelerating disease outbreak response, and tracking drug resistance. The East Africa Public Health Laboratory Network was established to bolster diagnostic and disease surveillance capacity. The network supports the introduction of regional quality standards; facilitates the rollout and evaluation of new diagnostic tools; and serves as a platform for training, research, and knowledge sharing. Participating facilities benefitted from state-of-the art investments, capacity building, and mentorship; conducted multicountry research studies; and contributed to disease outbreak response. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Laboratory and Physical Modelling of Building Ventilation Flows

    NASA Astrophysics Data System (ADS)

    Hunt, Gary

    2001-11-01

    Heating and ventilating buildings accounts for a significant fraction of the total energy budget of cities and an immediate challenge in building physics is for the design of sustainable, low-energy buildings. Natural ventilation provides a low-energy solution as it harness the buoyancy force associated with temperature differences between the internal and external environment, and the wind to drive a ventilating flow. Modern naturally-ventilated buildings use innovative design solutions, e.g. glazed atria and solar chimneys, to enhance the ventilation and demand for these and other designs has far outstripped our understanding of the fluid mechanics within these buildings. Developing an understanding of the thermal stratification and movement of air provides a considerable challenge as the flows involve interactions between stratification and turbulence and often in complex geometries. An approach that has provided significant new insight into these flows and which has led to the development of design guidelines for architects and ventilation engineers is laboratory modelling at small-scale in water tanks combined with physical modelling. Density differences to drive the flow in simplified plexiglass models of rooms or buildings are provided by fresh and salt water solutions, and wind flow is represented by a mean flow in a flume tank. In tandom with the experiments, theoretical models that capture the essential physics of these flows have been developed in order to generalise the experimental results to a wide range of typical building geometries and operating conditions. This paper describes the application and outcomes of these modelling techniques to the study of a variety of natural ventilation flows in buildings.

  17. Photocopy of drawing (original drawing of Photographic Laboratory Building in ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of drawing (original drawing of Photographic Laboratory Building in possession of MacDill Air Force Base, Civil Engineering, Tampa, Florida; 1939 architectural drawings by Construction Division, Office of the Quartermaster General) FRONT AND RIGHT SIDE ELEVATIONS AND SECTIONS - MacDill Air Force Base, Photographic Laboratory, 7718 Hanger Loop Drive, Tampa, Hillsborough County, FL

  18. Photocopy of drawing (original drawing of Photographic Laboratory Building in ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of drawing (original drawing of Photographic Laboratory Building in possession of MacDill Air Force Base, Civil Engineering, Tampa, Florida; 1939 architectural drawings by Construction Division, Office of the Quartermaster General) REAR AND LEFT SIDE ELEVATIONS AND SECTIONS - MacDill Air Force Base, Photographic Laboratory, 7718 Hanger Loop Drive, Tampa, Hillsborough County, FL

  19. Impacts: NIST Building and Fire Research Laboratory (technical and societal)

    NASA Astrophysics Data System (ADS)

    Raufaste, N. J.

    1993-08-01

    The Building and Fire Research Laboratory (BFRL) of the National Institute of Standards and Technology (NIST) is dedicated to the life cycle quality of constructed facilities. The report describes major effects of BFRL's program on building and fire research. Contents of the document include: structural reliability; nondestructive testing of concrete; structural failure investigations; seismic design and construction standards; rehabilitation codes and standards; alternative refrigerants research; HVAC simulation models; thermal insulation; residential equipment energy efficiency; residential plumbing standards; computer image evaluation of building materials; corrosion-protection for reinforcing steel; prediction of the service lives of building materials; quality of construction materials laboratory testing; roofing standards; simulating fires with computers; fire safety evaluation system; fire investigations; soot formation and evolution; cone calorimeter development; smoke detector standards; standard for the flammability of children's sleepwear; smoldering insulation fires; wood heating safety research; in-place testing of concrete; communication protocols for building automation and control systems; computer simulation of the properties of concrete and other porous materials; cigarette-induced furniture fires; carbon monoxide formation in enclosure fires; halon alternative fire extinguishing agents; turbulent mixing research; materials fire research; furniture flammability testing; standard for the cigarette ignition resistance of mattresses; support of navy firefighter trainer program; and using fire to clean up oil spills.

  20. Laboratory Directed Research and Development FY-10 Annual Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dena Tomchak

    2011-03-01

    The FY 2010 Laboratory Directed Research and Development (LDRD) Annual Report is a compendium of the diverse research performed to develop and ensure the INL's technical capabilities can support the future DOE missions and national research priorities. LDRD is essential to the INL -- it provides a means for the laboratory to pursue novel scientific and engineering research in areas that are deemed too basic or risky for programmatic investments. This research enhances technical capabilities at the laboratory, providing scientific and engineering staff with opportunities for skill building and partnership development.

  1. 10 CFR 434.505 - Reference building method.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...

  2. 10 CFR 434.505 - Reference building method.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...

  3. 10 CFR 434.505 - Reference building method.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...

  4. 10 CFR 434.505 - Reference building method.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...

  5. Space Planning for Laboratory Buildings | Climate Neutral Research Campuses

    Science.gov Websites

    facilities such as warehouses, offices, and high-tech laboratories have very different energy requirements , and a successful climate action plan will set aside adequate space for different activities. The Facility offices are housed in a different portion of the building than labs, resulting in lower cost

  6. 46 CFR 188.10-69 - Scientific laboratory.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Scientific laboratory. 188.10-69 Section 188.10-69 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS GENERAL PROVISIONS Definition of Terms Used in This Subchapter § 188.10-69 Scientific laboratory. This term means...

  7. 46 CFR 188.10-69 - Scientific laboratory.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Scientific laboratory. 188.10-69 Section 188.10-69 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS GENERAL PROVISIONS Definition of Terms Used in This Subchapter § 188.10-69 Scientific laboratory. This term means...

  8. 46 CFR 188.10-69 - Scientific laboratory.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Scientific laboratory. 188.10-69 Section 188.10-69 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS GENERAL PROVISIONS Definition of Terms Used in This Subchapter § 188.10-69 Scientific laboratory. This term means...

  9. 46 CFR 188.10-69 - Scientific laboratory.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Scientific laboratory. 188.10-69 Section 188.10-69 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS GENERAL PROVISIONS Definition of Terms Used in This Subchapter § 188.10-69 Scientific laboratory. This term means...

  10. 46 CFR 188.10-69 - Scientific laboratory.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Scientific laboratory. 188.10-69 Section 188.10-69 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS GENERAL PROVISIONS Definition of Terms Used in This Subchapter § 188.10-69 Scientific laboratory. This term means...

  11. 46 CFR 188.10-11 - Chemistry laboratory.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Chemistry laboratory. 188.10-11 Section 188.10-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS GENERAL PROVISIONS Definition of Terms Used in This Subchapter § 188.10-11 Chemistry laboratory. This term includes...

  12. 46 CFR 188.10-11 - Chemistry laboratory.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Chemistry laboratory. 188.10-11 Section 188.10-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS GENERAL PROVISIONS Definition of Terms Used in This Subchapter § 188.10-11 Chemistry laboratory. This term includes...

  13. 46 CFR 188.10-11 - Chemistry laboratory.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Chemistry laboratory. 188.10-11 Section 188.10-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS GENERAL PROVISIONS Definition of Terms Used in This Subchapter § 188.10-11 Chemistry laboratory. This term includes...

  14. 46 CFR 188.10-11 - Chemistry laboratory.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Chemistry laboratory. 188.10-11 Section 188.10-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS GENERAL PROVISIONS Definition of Terms Used in This Subchapter § 188.10-11 Chemistry laboratory. This term includes...

  15. 46 CFR 188.10-11 - Chemistry laboratory.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Chemistry laboratory. 188.10-11 Section 188.10-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS GENERAL PROVISIONS Definition of Terms Used in This Subchapter § 188.10-11 Chemistry laboratory. This term includes...

  16. 10 CFR 434.505 - Reference building method.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505.1...

  17. 19. VIEW OF THE GENERAL CHEMISTRY LABORATORY IN BUILDING 881. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. VIEW OF THE GENERAL CHEMISTRY LABORATORY IN BUILDING 881. (4/12/62) - Rocky Flats Plant, General Manufacturing, Support, Records-Central Computing, Southern portion of Plant, Golden, Jefferson County, CO

  18. 10. BUILDING 332, LARGE STOREROOM IN WESTERN PORTION OF BUILDING, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. BUILDING 332, LARGE STOREROOM IN WESTERN PORTION OF BUILDING, FROM APPROXIMATELY 60 FEET EAST OF WEST WALL AND GARAGE DOOR IN PHOTOGRAPH AA-9, LOOKING EAST, WITH ADJOINING STOREROOMS VISIBLE THROUGH FIRE DOORS. - Oakland Naval Supply Center, Dry Provisions Storehouses, Between Third & Fourth Streets, Between G & L Street, Oakland, Alameda County, CA

  19. A laboratory facility for research on wind-driven rain intrusion in building envelope assemblies

    Treesearch

    Samuel V. Glass

    2010-01-01

    Moisture management is critical for durable, energy-efficient buildings. To address the need for research on wind-driven rain intrusion in wall assemblies, the U.S. Forest Products Laboratory is developing a new facility. This paper describes the underlying principle of this facility and its capabilities.

  20. 10 CFR 434.503 - Prototype building procedure.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...

  1. 10 CFR 434.503 - Prototype building procedure.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...

  2. 10 CFR 434.503 - Prototype building procedure.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...

  3. 10 CFR 434.503 - Prototype building procedure.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...

  4. 10 CFR 434.503 - Prototype building procedure.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...

  5. 30 CFR 6.10 - Use of independent laboratories.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Use of independent laboratories. 6.10 Section 6..., AND APPROVAL OF MINING PRODUCTS TESTING AND EVALUATION BY INDEPENDENT LABORATORIES AND NON-MSHA PRODUCT SAFETY STANDARDS § 6.10 Use of independent laboratories. (a) MSHA will accept testing and...

  6. 10 CFR 435.306 - Selecting a life cycle effective proposed building design.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Selecting a life cycle effective proposed building design... Residential Buildings § 435.306 Selecting a life cycle effective proposed building design. In selecting... prototype, has the highest Net Savings or lowest total life cycle costs calculated in compliance with...

  7. 10 CFR 435.306 - Selecting a life cycle effective proposed building design.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Selecting a life cycle effective proposed building design... Residential Buildings § 435.306 Selecting a life cycle effective proposed building design. In selecting... prototype, has the highest Net Savings or lowest total life cycle costs calculated in compliance with...

  8. 10 CFR 435.306 - Selecting a life cycle effective proposed building design.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Selecting a life cycle effective proposed building design... Residential Buildings § 435.306 Selecting a life cycle effective proposed building design. In selecting... prototype, has the highest Net Savings or lowest total life cycle costs calculated in compliance with...

  9. 10 CFR 435.306 - Selecting a life cycle effective proposed building design.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Selecting a life cycle effective proposed building design... Residential Buildings § 435.306 Selecting a life cycle effective proposed building design. In selecting... prototype, has the highest Net Savings or lowest total life cycle costs calculated in compliance with...

  10. 30 CFR 6.10 - Use of independent laboratories.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PRODUCT SAFETY STANDARDS § 6.10 Use of independent laboratories. (a) MSHA will accept testing and... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Use of independent laboratories. 6.10 Section 6.10 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION...

  11. A Living Laboratory for Building-Grid Integration

    ScienceCinema

    Shankle, Steve; Goyal, Siddharth

    2018-01-16

    At PNNL we’re developing a test bed for control of how buildings interact with the grid—an important step toward helping buildings achieve their potential for reducing energy use and improving the management of the nation’s power systems. The test bed works by allowing researchers to conduct experiments on PNNL’s specially-equipped Systems Engineering Building. This unique resource will help the Department of Energy achieve its mission of reducing buildings energy use by 50 percent by 2030.

  12. VIEW OF 77710A REACTOR WING, LOOKING NORTH, SHOWING DOOR TO ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF 777-10A REACTOR WING, LOOKING NORTH, SHOWING DOOR TO PROCESS DEVELOPMENT PILE ROOM AND LABORATORY WING ON RIGHT IN BACKGROUND - Physics Assembly Laboratory, Area A/M, Savannah River Site, Aiken, Aiken County, SC

  13. Plasma creatinine in dogs: intra- and inter-laboratory variation in 10 European veterinary laboratories

    PubMed Central

    2011-01-01

    Background There is substantial variation in reported reference intervals for canine plasma creatinine among veterinary laboratories, thereby influencing the clinical assessment of analytical results. The aims of the study was to determine the inter- and intra-laboratory variation in plasma creatinine among 10 veterinary laboratories, and to compare results from each laboratory with the upper limit of its reference interval. Methods Samples were collected from 10 healthy dogs, 10 dogs with expected intermediate plasma creatinine concentrations, and 10 dogs with azotemia. Overlap was observed for the first two groups. The 30 samples were divided into 3 batches and shipped in random order by postal delivery for plasma creatinine determination. Statistical testing was performed in accordance with ISO standard methodology. Results Inter- and intra-laboratory variation was clinically acceptable as plasma creatinine values for most samples were usually of the same magnitude. A few extreme outliers caused three laboratories to fail statistical testing for consistency. Laboratory sample means above or below the overall sample mean, did not unequivocally reflect high or low reference intervals in that laboratory. Conclusions In spite of close analytical results, further standardization among laboratories is warranted. The discrepant reference intervals seem to largely reflect different populations used in establishing the reference intervals, rather than analytical variation due to different laboratory methods. PMID:21477356

  14. Avionics Systems Laboratory/Building 16. Historical Documentation

    NASA Technical Reports Server (NTRS)

    Slovinac, Patricia; Deming, Joan

    2011-01-01

    As part of this nation-wide study, in September 2006, historical survey and evaluation of NASA-owned and managed facilities that was conducted by NASA s Lyndon B. Johnson Space Center (JSC) in Houston, Texas. The results of this study are presented in a report entitled, "Survey and Evaluation of NASA-owned Historic Facilities and Properties in the Context of the U.S. Space Shuttle Program, Lyndon B. Johnson Space Center, Houston, Texas," prepared in November 2007 by NASA JSC s contractor, Archaeological Consultants, Inc. As a result of this survey, the Avionics Systems Laboratory (Building 16) was determined eligible for listing in the NRHP, with concurrence by the Texas State Historic Preservation Officer (SHPO). The survey concluded that Building 5 is eligible for the NRHP under Criteria A and C in the context of the U.S. Space Shuttle program (1969-2010). Because it has achieved significance within the past 50 years, Criteria Consideration G applies. At the time of this documentation, Building 16 was still used to support the SSP as an engineering research facility, which is also sometimes used for astronaut training. This documentation package precedes any undertaking as defined by Section 106 of the NHPA, as amended, and implemented in 36 CFR Part 800, as NASA JSC has decided to proactively pursue efforts to mitigate the potential adverse affects of any future modifications to the facility. It includes a historical summary of the Space Shuttle program; the history of JSC in relation to the SSP; a narrative of the history of Building 16 and how it supported the SSP; and a physical description of the structure. In addition, photographs documenting the construction and historical use of Building 16 in support of the SSP, as well as photographs of the facility documenting the existing conditions, special technological features, and engineering details, are included. A contact sheet printed on archival paper, and an electronic copy of the work product on CD, are

  15. Confirmatory radiological survey of the BORAX-V turbine building Idaho National Engineering Laboratory, Idaho Falls, Idaho

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stevens, G.H.; Coleman, R.L.; Jensen, M.K.

    1993-07-01

    An independent assessment of the remediation of the BORAX-V (Boiling Water Reactor Experiment) turbine building at the Idaho National Engineering Laboratory (INEL), Idaho Falls, Idaho, was accomplished by the Oak Ridge National Laboratory Pollutant Assessments Group (ORNL/PAG). The purpose of the assessment was to confirm the site`s compliance with applicable Department of Energy guidelines. The assessment included reviews of both the decontamination and decommissioning Plan and data provided from the pre- and post-remedial action surveys and an independent verification survey of the facility. The independent verification survey included determination of background exposure rates and soil concentrations, beta-gamma and gamma radiationmore » scans, smears for detection of removable contamination, and direct measurements for alpha and beta-gamma radiation activity on the basement and mezzanine floors and the building`s interior and exterior walls. Soil samples were taken, and beta-gamma and gamma radiation exposure rates were measured on areas adjacent to the building. Results of measurements on building surfaces at this facility were within established contamination guidelines except for elevated beta-gamma radiation levels located on three isolated areas of the basement floor. Following remediation of these areas, ORNL/PAG reviewed the remedial action contractor`s report and agreed that remediation was effective in removing the source of the elevated direct radiation. Results of all independent soil analyses for {sup 60}Co were below the detection limit. The highest {sup 137}Cs analysis result was 4.6 pCi/g; this value is below the INEL site-specific guideline of 10 pCi/g.« less

  16. Building bridges between clinical and forensic toxicology laboratories.

    PubMed

    Martin, Bernardino Barcelo; Gomila, Isabel; Noce, Valeria

    2018-05-09

    Clinical and forensic toxicology can be defined as the two disciplines involved the detection, identification and measurement of xenobiotics in biological and non-biological specimens to help in the diagnosis, treatment, prognosis, prevention of poisonings and to disclose causes and contributory causes of fatal intoxications, respectively. This article explores the close connections between clinical and forensic toxicology in overlapping areas of interest. An update has been carried out of the following seven areas of interest in analytical toxicology: doping control, sudden cardiac death (SCD), brain death, sudden infant death syndrome (SIDS) and Munchausen syndrome by proxy (MSBP), prenatal exposure to drugs and fetal alcohol syndrome (FAS), drug-facilitated crimes (DFC) and intoxications by new psychoactive substances (NPS). While issues such as SCD, SIDS or doping control are investigated mainly in forensic laboratories, other as prenatal exposure to drugs or FAS are mainly treated in clinical laboratories. On the other hand, areas such MSBP, DFC or the intoxications by NPS are of interest in both laboratories. Some of these topics are initially treated in hospital emergency departments, involving clinical laboratories and sometimes lately derived to forensic laboratories. Conversely, cases with initial medical-legal implications and fatalities are directly handled by forensic toxicology, but may trigger further studies in the clinical setting. Many areas of common interest between clinical and forensic laboratories are building bridges between them. The increasing relationships are improving the growth, the reliability and the robustness of both kind of laboratories. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  17. 75 FR 950 - Airworthiness Directives; The Boeing Company Model 777 Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-07

    ... inspecting the slat cans at the outboard slat number 3 and 12 outboard main track locations for holes and... of a hole in the inboard main track slat can for outboard slat number 12 on a Model 777 airplane. The... can. We are proposing this AD to detect and correct damage to the outboard slat main track slat cans...

  18. 10 CFR 435.306 - Selecting a life cycle effective proposed building design.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Selecting a life cycle effective proposed building design. 435.306 Section 435.306 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal...

  19. 32. The 1704B Supervisor's Office and Laboratory building, which also ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    32. The 1704-B Supervisor's Office and Laboratory building, which also contained the classified materials vault. This type of wooden construction was typical in the 100-B Area. Viewed from the northwest in September 1944. P-4445 - B Reactor, Richland, Benton County, WA

  20. 10. VIEW OF A DYNAMITE SHED, LOOKING WEST. THIS BUILDING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. VIEW OF A DYNAMITE SHED, LOOKING WEST. THIS BUILDING STANDS TO THE SOUTHWEST OF THE FAN HOUSE. - Tower Hill No. 2 Mine, Approximately 0.47 mile Southwest of intersection of Stone Church Road & Township Route 561, Hibbs, Fayette County, PA

  1. Small- and Medium-Sized Commercial Building Monitoring and Controls Needs: A Scoping Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Katipamula, Srinivas; Underhill, Ronald M.; Goddard, James K.

    2012-10-31

    Buildings consume over 40% of the total energy consumption in the U.S. A significant portion of the energy consumed in buildings is wasted because of the lack of controls or the inability to use existing building automation systems (BASs) properly. Much of the waste occurs because of our inability to manage and controls buildings efficiently. Over 90% of the buildings are either small-size (<5,000 sf) or medium-size (between 5,000 sf and 50,000 sf); these buildings currently do not use BASs to monitor and control their building systems from a central location. According to Commercial Building Energy Consumption Survey (CBECS), aboutmore » 10% of the buildings in the U.S. use BASs or central controls to manage their building system operations. Buildings that use BASs are typically large (>100,000 sf). Lawrence Berkeley National Laboratory (LBNL), Oak Ridge National Laboratory (ORNL) and Pacific Northwest National Laboratory (PNNL) were asked by the U.S. Department of Energy’s (DOE’s) Building Technologies Program (BTP) to identify monitoring and control needs for small- and medium-sized commercial buildings and recommend possible solutions. This study documents the needs and solutions for small- and medium-sized buildings.« less

  2. 10 CFR 435.303 - Requirements for the design of a Federal residential building.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Requirements for the design of a Federal residential building. 435.303 Section 435.303 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal...

  3. 10 CFR 435.303 - Requirements for the design of a Federal residential building.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Requirements for the design of a Federal residential building. 435.303 Section 435.303 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal...

  4. 10. Historic American Buildings Survey Ronald Partridge, Photographer August 1962 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey Ronald Partridge, Photographer August 1962 COLUMN ORNAMENT AT 226 'K' Street (Stanford Building) - Big Four Building, 220-226 K Street, Sacramento, Sacramento County, CA

  5. Communications and Tracking Development Laboratory/Building 44. Historical Documentation

    NASA Technical Reports Server (NTRS)

    Slovinac, Patricia

    2011-01-01

    As part of this nation-wide study, in September 2006, historical survey and evaluation of NASA-owned and managed facilities was conducted by NASA's Lyndon B. Johnson Space Center (JSC) in Houston, Texas. The results of this study are presented in a report entitled, Survey and Evaluation of NASA-owned Historic Facilities and Properties in the Context of the U.S. Space Shuttle Program, Lyndon B. Johnson Space Center, Houston, Texas, prepared in November 2007 by NASA JSC s contractor, Archaeological Consultants, Inc. As a result of this survey, the Communications and Tracking Development Laboratory (Building 44) was determined eligible for listing in the NRHP, with concurrence by the Texas State Historic Preservation Officer (SHPO). The survey concluded that Building 44 is eligible for the NRHP under Criteria A and C in the context of the U.S. Space Shuttle Program (1969-2010). Because it has achieved significance within the past 50 years, Criteria Consideration G applies. At the time of this documentation, Building 44 was still used to support the SSP as an engineering research facility, which is also sometimes used for astronaut training. This documentation package precedes any undertaking as defined by Section 106 of the NHPA, as amended, and implemented by 36 CFR Part 800, as NASA JSC has decided to proactively pursue efforts to mitigate the potential adverse affects of any future modifications to the facility. It includes a historical summary of the Space Shuttle Program; the history of JSC in relation to the SSP; a narrative of the history of Building 44 and how it supported the SSP; and a physical description of the building. In addition, photographs documenting the construction and historical use of Building 44 in support of the SSP, as well as photographs of the facility documenting the existing conditions, special technological features, and engineering details, are included. A contact sheet printed on archival paper, and an electronic copy of the work

  6. Laparoscopic cholecystectomy: an analysis of 777 cases.

    PubMed

    Perissat, J; Collet, D; Edye, M; Magne, E; Belliard, R; Desplantez, J

    1992-11-01

    Born in secret in 1987 and developed in an atmosphere of scepticism throughout 1988, laparoscopic cholecystectomy triumphed in 1989 and 1990, causing a veritable revolution in the world of general surgery. The 777 consecutive cases that are reported in this chapter reflect the spirit of these various periods. From conservatively restrictive, our indications widened to include 90% of gallstone cases. For us the sclero-atrophic gallbladder still constitutes the greatest endoscopic challenge and should be reserved for the most experienced operators. The rates for mortality (0.1%) and complications (3.3%), which include three common bile duct injuries (0.4%), are comparable to, if not better than, those for traditional cholecystectomy. The quality of recovery is markedly better: near absence of pain, short hospitalization, return to normal physical activity within 10 days, rapid return to work and preservation of the abdominal musculature in sportspeople. These advantages are unavailable to the 5.5% of patients for whom an intraoperative conversion to an open procedure is necessary. Their recovery is that of traditional cholecystectomy, which itself is far from being poor. The large multicentre studies, such as those carried out in France and Belgium recently, reporting 3708 cases, have reached identical conclusions. Laparoscopic cholecystectomy is set to become the gold standard for treatment of gallstones and is the first step towards surgical techniques of the 21st century which will be performed within the musculocutaneous envelope of the intact human body.

  7. Sandia National Laboratories, Tonopah Test Range Assembly Building 9B (Building 09-54): Photographs and Written Historical and Descriptive Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ullrich, Rebecca A.

    Assembly Building 9B (Building 09-54) is a contributing element to the Sandia National Laboratories (SNL) Tonopah Test Range (TTR) Historic District. The SNL TTR Historic District played a significant role in U.S. Cold War history in the areas of stockpile surveillance and non-nuclear field testing of nuclear weapons designs. The district covers approximately 179,200 acres and illustrates Cold War development testing of nuclear weapons components and systems. This report includes historical information, architectural information, sources of information, project information, maps, blueprints, and photographs.

  8. Upgrades and Enclosure of Building 15 at Technical Area 40: Los Alamos National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Plimpton, Kathryn D; Garcia, Kari L. M; Brunette, Jeremy Christopher

    The U.S. Department of Energy, National Nuclear Security Administration, Los Alamos Field Office (Field Office) proposes to upgrade and enclose Building 15 at Technical Area (TA) 40, Los Alamos National Laboratory. Building TA-40-15, a Cold War-era firing site, was determined eligible for listing in the National Register of Historic Places (Register) in DX Division’s Facility Strategic Plan: Consolidation and Revitalization at Technical Areas 6, 8, 9, 14, 15, 22, 36, 39, 40, 60, and 69 (McGehee et al. 2005). Building TA-40-15 was constructed in 1950 to support detonator testing. The firing site will be enclosed by a steel building tomore » create a new indoor facility that will allow for year-round mission capability. Enclosing TA-40-15 will adversely affect the building by altering the characteristics that make it eligible for the Register. In compliance with Section 106 of the National Historic Preservation Act of 1966, as amended, the Field Office is initiating consultation for this proposed undertaking. The Field Office is also requesting concurrence with the use of standard practices to resolve adverse effects as defined in the Programmatic Agreement among the U.S. Department of Energy, National Nuclear Security Administration, Los Alamos Field Office, the New Mexico State Historic Preservation Office and the Advisory Council on Historic Preservation Concerning Management of the Historic Properties at Los Alamos National Laboratory, Los Alamos, New Mexico.« less

  9. 10. Interior of Building 1040 (chapel), looking north Naval ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Interior of Building 1040 (chapel), looking north - Naval Air Station Chase Field, Building 1040, Enterprise Street, .37 mile South-Southeast of intersection of Texas State Highway 202 & Independence Street, Beeville, Bee County, TX

  10. 10. INTERIOR OF BUILDING 1606. VIEW TO SOUTH. Rocky ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. INTERIOR OF BUILDING 1606. VIEW TO SOUTH. - Rocky Mountain Arsenal, Cluster Bomb Assembly-Filling-Storage Building, 3500 feet South of Ninth Avenue; 2870 feet East of D Street, Commerce City, Adams County, CO

  11. Chemistry in a Large, Multidisciplinary Laboratory.

    ERIC Educational Resources Information Center

    Lingren, Wesley E.; Hughson, Robert C.

    1982-01-01

    Describes a science facility built at Seattle Pacific University for approximately 70 percent of the capital cost of a conventional science building. The building serves seven disciplines on a regular basis. The operation of the multidisciplinary laboratory, special features, laboratory security, and student experience/reactions are highlighted.…

  12. 2. VIEW OF THE MICROWAVE MELTER DEVELOPED BY THE RESEARCH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. VIEW OF THE MICROWAVE MELTER DEVELOPED BY THE RESEARCH AND DEVELOPMENT GROUP LOCATED IN BUILDING 701. THE MICROWAVE MELTER TRANSFORMED WASTE INTO A VITREOUS GLASS-LIKE SUBSTANCE, IMMOBILIZING THE WASTE, SO THAT IT COULD BE SHIPPED OFF SITE FOR DISPOSAL. (1/31/91) - Rocky Flats Plant, Design Laboratory, Northwest quadrant of Plant, between buildings 776-777 & 771, Golden, Jefferson County, CO

  13. Engine Propeller Research Building at the Lewis Flight Propulsion Laboratory

    NASA Image and Video Library

    1955-02-21

    The Engine Propeller Research Building, referred to as the Prop House, emits steam from its acoustic silencers at the National Advisory Committee for Aeronautics (NACA) Lewis Flight Propulsion Laboratory. In 1942 the Prop House became the first completed test facility at the new NACA laboratory in Cleveland, Ohio. It contained four test cells designed to study large reciprocating engines. After World War II, the facility was modified to study turbojet engines. Two of the test cells were divided into smaller test chambers, resulting in a total of six engine stands. During this period the NACA Lewis Materials and Thermodynamics Division used four of the test cells to investigate jet engines constructed with alloys and other high temperature materials. The researchers operated the engines at higher temperatures to study stress, fatigue, rupture, and thermal shock. The Compressor and Turbine Division utilized another test cell to study a NACA-designed compressor installed on a full-scale engine. This design sought to increase engine thrust by increasing its airflow capacity. The higher stage pressure ratio resulted in a reduction of the number of required compressor stages. The last test cell was used at the time by the Engine Research Division to study the effect of high inlet densities on a jet engine. Within a couple years of this photograph the Prop House was significantly altered again. By 1960 the facility was renamed the Electric Propulsion Research Building to better describe its new role in electric propulsion.

  14. 10 CFR 26.155 - Laboratory personnel.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Laboratory personnel. 26.155 Section 26.155 Energy NUCLEAR... for drugs of abuse; and (B) Appropriate training and/or experience in forensic applications of... individual with at least a bachelor's degree in the chemical or biological sciences, medical technology, or...

  15. Expansion of Surveillance for Vaccine-preventable Diseases: Building on the Global Polio Laboratory Network and the Global Measles and Rubella Laboratory Network Platforms.

    PubMed

    Mulders, Mick N; Serhan, Fatima; Goodson, James L; Icenogle, Joseph; Johnson, Barbara W; Rota, Paul A

    2017-07-01

    Laboratory networks were established to provide accurate and timely laboratory confirmation of infections, an essential component of disease surveillance systems. The World Health Organization (WHO) coordinates global laboratory surveillance of vaccine-preventable diseases (VPDs), including polio, measles and rubella, yellow fever, Japanese encephalitis, rotavirus, and invasive bacterial diseases. In addition to providing high-quality laboratory surveillance data to help guide disease control, elimination, and eradication programs, these global networks provide capacity-building and an infrastructure for public health laboratories. There are major challenges with sustaining and expanding the global laboratory surveillance capacity: limited resources and the need for expansion to meet programmatic goals. Here, we describe the WHO-coordinated laboratory networks supporting VPD surveillance and present a plan for the further development of these networks. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.

  16. 10. BUILDING NO. 445, PHYSICS LAB (FORMERLY GUN BAG LOADING), ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. BUILDING NO. 445, PHYSICS LAB (FORMERLY GUN BAG LOADING), LOOKING AT SOUTHEAST CORNER. BUILDING NO. 332, CHANGE HOUSE, IN RIGHT BACKGROUND; BUILDING NO. 445-F, MAGAZINE, IN LEFT BACKGROUND. - Picatinny Arsenal, 400 Area, Gun Bag Loading District, State Route 15 near I-80, Dover, Morris County, NJ

  17. The 10 Building Blocks of High-Performing Primary Care

    PubMed Central

    Bodenheimer, Thomas; Ghorob, Amireh; Willard-Grace, Rachel; Grumbach, Kevin

    2014-01-01

    Our experiences studying exemplar primary care practices, and our work assisting other practices to become more patient centered, led to a formulation of the essential elements of primary care, which we call the 10 building blocks of high-performing primary care. The building blocks include 4 foundational elements—engaged leadership, data-driven improvement, empanelment, and team-based care—that assist the implementation of the other 6 building blocks—patient-team partnership, population management, continuity of care, prompt access to care, comprehensiveness and care coordination, and a template of the future. The building blocks, which represent a synthesis of the innovative thinking that is transforming primary care in the United States, are both a description of existing high-performing practices and a model for improvement. PMID:24615313

  18. The 10 building blocks of high-performing primary care.

    PubMed

    Bodenheimer, Thomas; Ghorob, Amireh; Willard-Grace, Rachel; Grumbach, Kevin

    2014-01-01

    Our experiences studying exemplar primary care practices, and our work assisting other practices to become more patient centered, led to a formulation of the essential elements of primary care, which we call the 10 building blocks of high-performing primary care. The building blocks include 4 foundational elements-engaged leadership, data-driven improvement, empanelment, and team-based care-that assist the implementation of the other 6 building blocks-patient-team partnership, population management, continuity of care, prompt access to care, comprehensiveness and care coordination, and a template of the future. The building blocks, which represent a synthesis of the innovative thinking that is transforming primary care in the United States, are both a description of existing high-performing practices and a model for improvement.

  19. Building No. 5, Main Building; Building NO. 9, Guard House ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Building No. 5, Main Building; Building NO. 9, Guard House (left). Viewed from across corner Lakeside Avenue and Main Street - Thomas A. Edison Laboratories, Main Street & Lakeside Avenue, West Orange, Essex County, NJ

  20. 8. Historic American Buildings Survey Verlin Berry, Photographer November 10, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. Historic American Buildings Survey Verlin Berry, Photographer November 10, 1977 FIRST FLOOR, DETAIL OF PRESSED TIN CEILING - 111 West First Street (Commercial Building), Mishawaka, St. Joseph County, IN

  1. 10. DETAIL VIEW OF ADMINISTRATION BUILDING. INTERIOR VIEW SHOWING SECOND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. DETAIL VIEW OF ADMINISTRATION BUILDING. INTERIOR VIEW SHOWING SECOND FLOOR CORRIDOR. VIEW TO NORTH. - VA Medical Center, Aspinwall Division, Administration Building, 5103 Delafield Avenue, Aspinwall, Allegheny County, PA

  2. Aerial View of NACA's Lewis Flight Propulsion Research Laboratory

    NASA Image and Video Library

    1946-05-21

    The National Advisory Committee for Aeronautics (NACA) Lewis Flight Propulsion Laboratory in Cleveland, Ohio as seen from the west in May 1946. The Cleveland Municipal Airport is located directly behind. The laboratory was built in the early 1940s to resolve problems associated with aircraft engines. The initial campus contained seven principal buildings: the Engine Research Building, hangar, Fuels and Lubricants Building, Administration Building, Engine Propeller Research Building, Altitude Wind Tunnel, and Icing Research Tunnel. These facilities and their associated support structures were located within an area occupying approximately one-third of the NACA’s property. After World War II ended, the NACA began adding new facilities to address different problems associated with the newer, more powerful engines and high speed flight. Between 1946 and 1955, four new world-class test facilities were built: the 8- by 6-Foot Supersonic Wind Tunnel, the Propulsion Systems Laboratory, the Rocket Engine Test Facility, and the 10- by 10-Foot Supersonic Wind Tunnel. These large facilities occupied the remainder of the NACA’s semicircular property. The Lewis laboratory expanded again in the late 1950s and early 1960s as the space program commenced. Lewis purchased additional land in areas adjacent to the original laboratory and acquired a large 9000-acre site located 60 miles to the west in Sandusky, Ohio. The new site became known as Plum Brook Station.

  3. 33 CFR 165.777 - Security Zone; West Basin, Port Canaveral Harbor, Cape Canaveral, Florida.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... clearly states the location of the security zone and the times it will be enforced. This will be the... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Security Zone; West Basin, Port... Guard District § 165.777 Security Zone; West Basin, Port Canaveral Harbor, Cape Canaveral, Florida. (a...

  4. 10. Historic American Buildings Survey Allen L. Hubbard, Photographer December ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey Allen L. Hubbard, Photographer December 1, 1936 (Northwest cor. room 2nd floor) East Wall - Fort Western, Main Building, Bowman Street, Augusta, Kennebec County, ME

  5. 10. VIEW OF PIER 42 BULKHEAD BUILDING INTERIOR (PARTIALLY DEMOLISHED) ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. VIEW OF PIER 42 BULKHEAD BUILDING INTERIOR (PARTIALLY DEMOLISHED) WITH JAVA HOUSE IN BACKGROUND, FACING NORTH. - Pier 42 Bulkhead Building, Pier 42, Embarcadero, San Francisco, San Francisco County, CA

  6. 10. ENGINE TEST CELL BUILDING INTERIOR. CELL 4, MOUNTING STAND. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. ENGINE TEST CELL BUILDING INTERIOR. CELL 4, MOUNTING STAND. LOOKING NORTHWEST. - Fairchild Air Force Base, Engine Test Cell Building, Near intersection of Arnold Street & George Avenue, Spokane, Spokane County, WA

  7. A KPC-scale X-ray jet in the BL LAC Source S5 2007+777

    NASA Technical Reports Server (NTRS)

    Sambruna, Rita; Maraschi, Laura; Tavecchio, Fabrizio

    2008-01-01

    The BL Lac S3 2007++777, a classical radio-selected BL Lac from the sample of Stirkel et al. exhibiting an extended (19") radio jet. was observed with Chandra revealing an X-ray jet with simi1ar morphology. The hard X-ray spectrum and broad band SED is consistent with an IC/CMB origin for the X-ray emission, implying a highly relativistic flow at small angle to the line of sight with an unusually large deprojected length, 300 kpc. A structured jet consisting of a fast spine and slow wall is consistent with the observations.

  8. Simulation Technology Laboratory Building 970 hazards assessment document

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wood, C.L.; Starr, M.D.

    1994-11-01

    The Department of Energy Order 5500.3A requires facility-specific hazards assessments be prepared, maintained, and used for emergency planning purposes. This hazards assessment document describes the chemical and radiological hazards associated with the Simulation Technology Laboratory, Building 970. The entire inventory was screened according to the potential airborne impact to onsite and offsite individuals. The air dispersion model, ALOHA, estimated pollutant concentrations downwind from the source of a release, taking into consideration the toxicological and physical characteristics of the release site, the atmospheric conditions, and the circumstances of the release. The greatest distances at which a postulated facility event will producemore » consequences exceeding the ERPG-2 and Early Severe Health Effects thresholds are 78 and 46 meters, respectively. The highest emergency classification is a Site Area Emergency. The Emergency Planning Zone is 100 meters.« less

  9. Derived concentration guideline levels for Argonne National Laboratory's building 310 area.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kamboj, S., Dr.; Yu, C ., Dr.

    2011-08-12

    The derived concentration guideline level (DCGL) is the allowable residual radionuclide concentration that can remain in soil after remediation of the site without radiological restrictions on the use of the site. It is sometimes called the single radionuclide soil guideline or the soil cleanup criteria. This report documents the methodology, scenarios, and parameters used in the analysis to support establishing radionuclide DCGLs for Argonne National Laboratory's Building 310 area.

  10. 10. Threequarter view of southwest corner of building 500 and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Three-quarter view of southwest corner of building 500 and G-wing, looking northeast - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  11. 7. Historic American Buildings Survey Verlin Berry, Photographer November 10, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. Historic American Buildings Survey Verlin Berry, Photographer November 10, 1977 FIRST FLOOR, VIEW OF PRESSED TIN CEILING WITH WOOD BLOCKING AT CROWN MOLDING - 111 West First Street (Commercial Building), Mishawaka, St. Joseph County, IN

  12. 10. Historic American Buildings Survey John O. Brostrup, Photographer March ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey John O. Brostrup, Photographer March 30, 1936 10:00 A.M. DETAIL FROM SOUTHEAST - Friendship, Kolbies Corner, State Routes 214 & 556, Largo, Prince George's County, MD

  13. 10. Historic view of the building: 'Warren Street from State ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic view of the building: 'Warren Street from State Street' ca. 1893. Courtesy of Trenton Free Public Library. 2-6 East State Street is to the right of the image, with the sign for a dentist prominent on the corner. The mass of wires entering the fourth floor window suggests the location of the Western Union Telegraph Office in the building. - 2-6 East State Street (Commercial Building), 2-6 East State Street, Trenton, Mercer County, NJ

  14. Reliability increases from combining 50,000- and 777,000-marker genotypes from four countries

    USDA-ARS?s Scientific Manuscript database

    Genomic predictions were compared on U.S. scale after combining 50,000 (50K) and 777,000 (HD) marker genotypes across countries. The genotyped Holsteins included 161,341 animals with five marker densities including 1,510 with HD. Imputation was more accurate with FImpute than with findhap across the...

  15. 10. Exterior view, showing the structural details and tanks above ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Exterior view, showing the structural details and tanks above at walk-in entry level (bottom) of Test Cell 7, Systems Integration Laboratory Building (T-28), looking west. - Air Force Plant PJKS, Systems Integration Laboratory, Systems Integration Laboratory Building, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  16. A KPC-Scale X-Ray Jet in the BL Lac Source S5 2007+777

    NASA Technical Reports Server (NTRS)

    Sambruna, Rita M.; Donato, Davide; Cheung, C.C.; Tavecchio, F.; Maraschi, L.

    2008-01-01

    X-ray jets in AGN are commonly observed in FRII and FRI radiogalaxies, but rarely in BL Lacs, most probably due to their orientation close to the line of sight and the ensuing foreshortening effects. Only three BL Lacs are known so far to contain a kpc-scale X-ray jet. In this paper, we present the evidence for the existence of a fourth extended X-ray jet in the classical radio-selected source S5 2007+777, which for its hybrid FRI/II radio morphology has been classified as a HYMOR (HYbrid MOrphology Radio source). Our Chandra ACISS observations of this source revealed an X-ray counterpart to the 19"-long radio jet. Interestingly, the X-ray properties of the kpc-scale jet in S5 2007+777 are very similar to those observed in FRII jets. First, the X-ray morphology closely mirrors the radio one, with the X-rays being concentrated in the discrete radio knots. Second, the X-ray continuum of the jet/brightest knot is described by a very hard power law, with photon index gamma(sub x) approximately 1. Third, the optical upper limit from archival HST data implies a concave radio-to-X-ray SED. If the X-ray emission is attributed to IC/CMB with equipartition, strong beaming (delta= 13) is required, implying a very large scale (Mpc) jet. The beaming requirement can be somewhat relaxed assuming a magnetic field lower than equipartition. Alternatively, synchrotron emission from a second population of very high-energy electrons is viable. Comparison to other HYMOR jets detected with Chandra is discussed, as well as general implications for the origin of the FRI/II division.

  17. 10. Historic exterior view of Building 100. August 22, 1957. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic exterior view of Building 100. August 22, 1957. On file at NASA Plumbrook Research Center, Sandusky, Ohio. NASA photo number C-45766. - Rocket Engine Testing Facility, GRC Building No. 100, NASA Glenn Research Center, Cleveland, Cuyahoga County, OH

  18. US Army Research Laboratory (ARL) Standard for Characterization of Electric-Field Sensors, 10 Hz to 10 kHz

    DTIC Science & Technology

    2016-11-01

    Disclaimers The findings in this report are not to be construed as an official Department of the Army position unless so designated by other...unlimited. 13. SUPPLEMENTARY NOTES 14. ABSTRACT The US Army Research Laboratory (ARL) has designed and build a one-of-a-kind electric-field sensor...direction. (Right) Computer- aided design model of the ARL electric-field cage with insulated mounting

  19. 10. CONTEXT VIEW LOOKING SOUTHEAST SHOWING BUILDING 342 (STORAGE MAGAZINE) ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. CONTEXT VIEW LOOKING SOUTHEAST SHOWING BUILDING 342 (STORAGE MAGAZINE) ON LEFT AND BUILDING 343 (STORAGE MAGAZINE) ON RIGHT IN STORAGE AREA. - Loring Air Force Base, Weapons Storage Area, Northeastern corner of base at northern end of Maine Road, Limestone, Aroostook County, ME

  20. 10. Historic American Buildings Survey, Bill Engdahl for HedrichBlessing, Photographers, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey, Bill Engdahl for Hedrich-Blessing, Photographers, February, 1979 STORE DISPLAY WINDOW. - Alonso Building, 510-514 East Saint Charles Street, Brownsville, Cameron County, TX

  1. Top ten challenges when interfacing a laboratory information system to an electronic health record: Experience at a large academic medical center.

    PubMed

    Petrides, Athena K; Tanasijevic, Milenko J; Goonan, Ellen M; Landman, Adam B; Kantartjis, Michalis; Bates, David W; Melanson, Stacy E F

    2017-10-01

    Recent U.S. government regulations incentivize implementation of an electronic health record (EHR) with computerized order entry and structured results display. Many institutions have also chosen to interface their EHR to their laboratory information system (LIS). Reported long-term benefits include increased efficiency and improved quality and safety. In order to successfully implement an interfaced EHR-LIS, institutions must plan years in advance and anticipate the impact of an integrated system. It can be challenging to fully understand the technical, workflow and resource aspects and adequately prepare for a potentially protracted system implementation and the subsequent stabilization. We describe the top ten challenges that we encountered in our clinical laboratories following the implementation of an interfaced EHR-LIS and offer suggestions on how to overcome these challenges. This study was performed at a 777-bed, tertiary care center which recently implemented an interfaced EHR-LIS. Challenges were recorded during EHR-LIS implementation and stabilization and the authors describe the top ten. Our top ten challenges were selection and harmonization of test codes, detailed training for providers on test ordering, communication with EHR provider champions during the build process, fluid orders and collections, supporting specialized workflows, sufficient reports and metrics, increased volume of inpatient venipunctures, adequate resources during stabilization, unanticipated changes to laboratory workflow and ordering specimens for anatomic pathology. A few suggestions to overcome these challenges include regular meetings with clinical champions, advanced considerations of reports and metrics that will be needed, adequate training of laboratory staff on new workflows in the EHR and defining all tests including anatomic pathology in the LIS. EHR-LIS implementations have many challenges requiring institutions to adapt and develop new infrastructures. This article

  2. Aircraft in the Flight Research Building at the Aircraft Engine Research Laboratory

    NASA Image and Video Library

    1944-06-21

    A Consolidated B–24D Liberator (left), Boeing B–29 Superfortress (background), and Lockheed RA–29 Hudson (foreground) parked inside the Flight Research Building at the National Advisory Committee for Aeronautics (NACA) Aircraft Engine Research Laboratory in Cleveland, Ohio. A P–47G Thunderbolt and P–63A King Cobra are visible in the background. The laboratory utilized 15 different aircraft during the final 2.5 years of World War II. This starkly contrasts with the limited-quantity, but long-duration aircraft of the NASA’s modern fleet. The Flight Research Building is a 272- by 150-foot hangar with an internal height ranging from 40 feet at the sides to 90 feet at its apex. The steel support trusses were pin-connected at the top with tension members extending along the corrugated transite walls down to the floor. The 37.5-foot-tall and 250-foot-long doors on either side can be opened in sections. The hangar included a shop area and stock room along the far wall, and a single-story office wing with nine offices, behind the camera. The offices were later expanded. The hangar has been in continual use since its completion in December 1942. Nearly 70 different aircraft have been sheltered here over the years. Temporary offices were twice constructed over half of the floor area when office space was at a premium.

  3. 10. Historic American Buildings Survey ARCHITECT'S DRAWING Copy negative from ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey ARCHITECT'S DRAWING Copy negative from book published by Secretary of Treasury, 1857, consisting of 21 plates. In office of the Building Manager, General Services Administration, New Orleans - U.S. Custom House, 423 Canal Street, New Orleans, Orleans Parish, LA

  4. Environmental assessment for the proposed construction and operation of a Genome Sequencing Facility in Building 64 at Lawrence Berkeley Laboratory, Berkeley, California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-04-01

    This document is an Environmental Assessment (EA) for a proposed project to modify 14,900 square feet of an existing building (Building 64) at Lawrence Berkeley Laboratory (LBL) to operate as a Genome Sequencing Facility. This EA addresses the potential environmental impacts from the proposed modifications to Building 64 and operation of the Genome Sequencing Facility. The proposed action is to modify Building 64 to provide space and equipment allowing LBL to demonstrate that the Directed DNA Sequencing Strategy can be scaled up from the current level of 750,000 base pairs per year to a facility that produces over 6,000,000 basemore » pairs per year, while still retaining its efficiency.« less

  5. Decommissioning of Active Ventilation Systems in a Nuclear R and D Facility to Prepare for Building Demolition (Whiteshell Laboratories Decommissioning Project, Canada) - 13073

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilcox, Brian; May, Doug; Howlett, Don

    2013-07-01

    Whiteshell Laboratories (WL) is a nuclear research establishment owned by the Canadian government and operated by Atomic Energy of Canada Limited (AECL) since the early 1960's. WL is currently under a decommissioning license and the mandate is to remediate the nuclear legacy liabilities in a safe and cost effective manner. The WL Project is the first major nuclear decommissioning project in Canada. A major initiative underway is to decommission and demolish the main R and D Laboratory complex. The Building 300 R and D complex was constructed to accommodate laboratories and offices which were mainly used for research and developmentmore » associated with organic-cooled reactors, nuclear fuel waste management, reactor safety, advanced fuel cycles and other applications of nuclear energy. Building 300 is a three storey structure of approximately 16,000 m{sup 2}. In order to proceed with building demolition, the contaminated systems inside the building have to be characterized, removed, and the waste managed. There is a significant focus on volume reduction of radioactive waste for the WL project. The active ventilation system is one of the significant contaminated systems in Building 300 that requires decommissioning and removal. The active ventilation system was designed to manage hazardous fumes and radioactivity from ventilation devices (e.g., fume hoods, snorkels and glove boxes) and to prevent the escape of airborne hazardous material outside of the laboratory boundary in the event of an upset condition. The system includes over 200 ventilation devices and 32 active exhaust fan units and high efficiency particulate air (HEPA) filters. The strategy to remove the ventilation system was to work from the laboratory end back to the fan/filter system. Each ventilation duct was radiologically characterized. Fogging was used to minimize loose contamination. Sections of the duct were removed by various cutting methods and bagged for temporary storage prior to

  6. 10. OVERALL VIEW OF THE MAIN LOBBY OF BUILDING 1; ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. OVERALL VIEW OF THE MAIN LOBBY OF BUILDING 1; SHOWING EGYPTIAN MOTIF DECORATIVE DETAIL OF THE ENGAGED COLUMNS, CORNICE & SOFFIT, DEDICATION PLAQUE, AND FLOOR MOSAICS; LOOKING SE. (Ryan & Harms) - Veterans Administration Medical Center, Building No. 1, Old State Route 13 West, Marion, Williamson County, IL

  7. Monitoring laboratory data across manufacturers and laboratories--A prerequisite to make "Big Data" work.

    PubMed

    Goossens, Kenneth; Van Uytfanghe, Katleen; Twomey, Patrick J; Thienpont, Linda M

    2015-05-20

    "The Percentiler" project provides quasi real-time access to patient medians across laboratories and manufacturers. This data can serve as "clearinghouse" for electronic health record applications, e.g., use of laboratory data for global health-care research. Participants send their daily outpatient medians to the Percentiler application. After 6 to 8weeks, the laboratory receives its login information, which gives access to the user interface. Data is assessed by peer group, i.e., 10 or more laboratories using the same test system. Participation is free of charge. Participation is global with, to date, >120 laboratories and >250 instruments. Up to now, several reports have been produced that address i) the general features of the project, ii) peer group observations; iii) synergisms between "The Percentiler" and dedicated external quality assessment surveys. Reasons for long-term instability and bias (calibration- or lot-effects) have been observed for the individual laboratory and manufacturers. "The Percentiler" project has the potential to build a continuous, global evidence base on in vitro diagnostic test comparability and stability. As such, it may be beneficial for all stakeholders and, in particular, the patient. The medical laboratory is empowered for contributing to the development, implementation, and management of global health-care policies. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. VOLATILE ORGANIC CHEMICALS IN 10 PUBLIC-ACCESS BUILDINGS

    EPA Science Inventory

    The U.S. EPA carried out studies of indoor air quality in 10 buildings. Qualitative analysis identified over 200 aromatics, halogens, esters, alcohols, phenols, ethers, ketones, aldehydes, and epoxides, in addition to several hundred aliphatic hydrocarbons. The total organic load...

  9. [Building and implementation of management system in laboratories of the National Institute of Hygiene].

    PubMed

    Rozbicka, Beata; Brulińska-Ostrowska, Elzbieta

    2008-01-01

    The rules of good laboratory practice have always been observed in the laboratories of National Institute of Hygiene (NIH) and the reliability of the results has been carefully cared after when performing tests for clients. In 2003 the laboratories performing analyses related to food safety were designated as the national reference laboratories. This, added to the necessity of compliance with work standards and requirements of EU legislation and to the need of confirmation of competence by an independent organisation, led to a decision to seek accreditation of Polish Centre of Accreditation (PCA). The following stages of building and implementation of management system were presented: training, modifications of Institute's organisational structure, elaboration of management system's documentation, renovation and refurbishment of laboratory facilities, implementation of measuring and test equipment's supervision, internal audits and management review. The importance of earlier experiences and achievements with regard to validation of analytical methods and guarding of the quality of the results through organisation and participation in proficiency tests was highlighted. Current status of accreditation of testing procedures used in NIH laboratories that perform analyses in the field of chemistry, microbiology, radiobiology and medical diagnostic tests was presented.

  10. 10. Historic American Buildings Survey W. N. Manning, Photographer, September ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey W. N. Manning, Photographer, September 10, 1935 MANTEL AND WINDOW TREATMENT IN PARLOR, WEST FRONT ROOM - James Ellington House, Oak Bowery Road vicinity, Gold Hill, Lee County, AL

  11. REACTOR SERVICES BUILDING, TRA635, INTERIOR. ALSO KNOWN AS MATERIAL RECEIVING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    REACTOR SERVICES BUILDING, TRA-635, INTERIOR. ALSO KNOWN AS MATERIAL RECEIVING AREA AND LABORATORY. CAMERA ON FIRST FLOOR FACING NORTH TOWARD MTR BUILDING. MOCK-UP AREA WAS TO THE RIGHT OF VIEW. INL NEGATIVE NO. HD46-10-1. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  12. 1. View of EPA Farm Lab Building 1506, facing south ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. View of EPA Farm Lab Building 15-06, facing south - Nevada Test Site, Environmental Protection Agency Farm, Laboratory Building, Area 15, Yucca Flat, 10-2 Road near Circle Road, Mercury, Nye County, NV

  13. Draftsmen at Work during Construction of the Aircraft Engine Research Laboratory

    NASA Image and Video Library

    1942-09-21

    The National Advisory Committee for Aeronautics (NACA) Aircraft Engine Research Laboratory was designed by a group of engineers at the Langley Memorial Aeronautical Laboratory in late 1940 and 1941. Under the guidance of Ernest Whitney, the men worked on drawings and calculations in a room above Langley’s Structural Research Laboratory. The main Aircraft Engine Research Laboratory design group originally consisted of approximately 30 engineers and draftsmen, but there were smaller groups working separately on specific facilities. The new engine lab would have six principal buildings: the Engine Research Building, hangar, Fuels and Lubricants Building, Administration Building, Propeller Test Stand, and Altitude Wind Tunnel. In December 1941 most of those working on the project transferred to Cleveland from Langley. Harrison Underwood and Charles Egan led 18 architectural, 26 machine equipment, 3 structural and 10 mechanical draftsmen. Initially these staff members were housed in temporary offices in the hangar. As sections of the four-acre Engine Research Building were completed in the summer of 1942, the design team began relocating there. The Engine Research Building contained a variety of test cells and laboratories to address virtually every aspect of piston engine research. It also contained a two-story office wing, seen in this photograph that would later house many of the powerplant research engineers.

  14. 10. View of Dundee Textile Company Mill looking west; Building ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. View of Dundee Textile Company Mill looking west; Building No. 4 at right, Building No. 3 at center, Ackerman Avenue in foreground - Dundee Canal Industrial Historic District, Beginning at George Street in Passaic & extending north along Dundee Canal approximately 1.2 miles to Canal headgates opposite East Clifton Avenue in Clifton, Passaic, Passaic County, NJ

  15. 10. View of back side of radar scanner building no. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. View of back side of radar scanner building no. 104 showing passageway links to other building to east and DR 1 antenna in background. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  16. 10. Photocopy of Sheet 2 of Building Plan R451, (USDA, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Photocopy of Sheet 2 of Building Plan R4-51, (USDA, Forest Service, Intermountain Region, Ogden. File 7300, 'Buildings'.) Framing and Foundation Plans. - Buffalo Guard Station, Office, U.S. Highway 20/191 at Buffalo River, Island Park, Fremont County, ID

  17. The laboratory efficiencies initiative: partnership for building a sustainable national public health laboratory system.

    PubMed

    Ridderhof, John C; Moulton, Anthony D; Ned, Renée M; Nicholson, Janet K A; Chu, May C; Becker, Scott J; Blank, Eric C; Breckenridge, Karen J; Waddell, Victor; Brokopp, Charles

    2013-01-01

    Beginning in early 2011, the Centers for Disease Control and Prevention and the Association of Public Health Laboratories launched the Laboratory Efficiencies Initiative (LEI) to help public health laboratories (PHLs) and the nation's entire PHL system achieve and maintain sustainability to continue to conduct vital services in the face of unprecedented financial and other pressures. The LEI focuses on stimulating substantial gains in laboratories' operating efficiency and cost efficiency through the adoption of proven and promising management practices. In its first year, the LEI generated a strategic plan and a number of resources that PHL directors can use toward achieving LEI goals. Additionally, the first year saw the formation of a dynamic community of practitioners committed to implementing the LEI strategic plan in coordination with state and local public health executives, program officials, foundations, and other key partners.

  18. The Laboratory Efficiencies Initiative: Partnership for Building a Sustainable National Public Health Laboratory System

    PubMed Central

    Moulton, Anthony D.; Ned, Renée M.; Nicholson, Janet K.A.; Chu, May C.; Becker, Scott J.; Blank, Eric C.; Breckenridge, Karen J.; Waddell, Victor; Brokopp, Charles

    2013-01-01

    Beginning in early 2011, the Centers for Disease Control and Prevention and the Association of Public Health Laboratories launched the Laboratory Efficiencies Initiative (LEI) to help public health laboratories (PHLs) and the nation's entire PHL system achieve and maintain sustainability to continue to conduct vital services in the face of unprecedented financial and other pressures. The LEI focuses on stimulating substantial gains in laboratories' operating efficiency and cost efficiency through the adoption of proven and promising management practices. In its first year, the LEI generated a strategic plan and a number of resources that PHL directors can use toward achieving LEI goals. Additionally, the first year saw the formation of a dynamic community of practitioners committed to implementing the LEI strategic plan in coordination with state and local public health executives, program officials, foundations, and other key partners. PMID:23997300

  19. 7. View of interior, EPA Farm Lab Building 1506 milk ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. View of interior, EPA Farm Lab Building 15-06 milk room, facing west - Nevada Test Site, Environmental Protection Agency Farm, Laboratory Building, Area 15, Yucca Flat, 10-2 Road near Circle Road, Mercury, Nye County, NV

  20. 6. View of interior, EPA Farm Lab Building 1506 milking ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. View of interior, EPA Farm Lab Building 15-06 milking area, facing northwest - Nevada Test Site, Environmental Protection Agency Farm, Laboratory Building, Area 15, Yucca Flat, 10-2 Road near Circle Road, Mercury, Nye County, NV

  1. 10. Photocopy of Sheet 1 of Building Plan R453 (USDA, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Photocopy of Sheet 1 of Building Plan R4-53 (USDA, Forest Service, Intermountain Region, Ogden. File 7300, 'Buildings'.) FRONT AND SIDE ELEVATIONS AND FLOOR PLAN - Buffalo Guard Station, Residence, U.S. Highway 20/191 at Buffalo River, Island Park, Fremont County, ID

  2. Building No. 1, left; Building No. 9, Guard House, center; ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Building No. 1, left; Building No. 9, Guard House, center; Building No. 5, Main Building, right. View from across Main Street - Thomas A. Edison Laboratories, Main Street & Lakeside Avenue, West Orange, Essex County, NJ

  3. 10. Historic American Buildings Survey, Plate # 50, 'Wohnhaus Martin, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey, Plate # 50, 'Wohnhaus Martin, Buffalo, N. Y. Kamin in Wohnzimmer' in Frank Lloyd Wright Ausgefuhrte Bauten (Berlin: Ernst Wasmuth A. G., 1911), FIREPLACE IN LIVING ROOM, WEST SIDE. - Darwin D. Martin House, 125 Jewett Parkway, Buffalo, Erie County, NY

  4. Former Administration Building

    NASA Image and Video Library

    2016-10-27

    This archival image was released as part of a gallery comparing JPL's past and present, commemorating the 80th anniversary of NASA's Jet Propulsion Laboratory on Oct. 31, 2016. Building 11, one of the oldest buildings on lab, was once JPL's central administration building. It is now the Space Sciences Laboratory. This picture dates back to May 1943. http://photojournal.jpl.nasa.gov/catalog/PIA21201

  5. 10. Historic American Buildings Survey Josiah T. Tubby, Photographer September ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey Josiah T. Tubby, Photographer September 1936 DETAIL OF MANTEL (east bed room) - Jefferds Tavern, Harraseekit Road (moved to U.S. Route 1A, York), Wells, York County, ME

  6. Building M7-0505 Treatment Tank (SWMU 039) Annual Performance Monitoring Report

    NASA Technical Reports Server (NTRS)

    2015-01-01

    This Annual Performance Monitoring Report presents a summary of Interim Measure (IM) activities and an evaluation of data collected during the third year (June 2014 to September 2015) of operation, maintenance, and monitoring (OM&M) conducted at the Building M7-505 (M505) Treatment Tank area, Kennedy Space Center (KSC), Florida ("the Site"). Under KSC's Resource Conservation and Recovery Act Corrective Action Program, the M505 Treatment Tank area was designated Solid Waste Management Unit 039. Arcadis U.S., Inc. (Arcadis) began IM activities on January 10, 2012, after completion of construction of an in situ air sparge (IAS) system to remediate volatile organic compounds (VOCs) in groundwater at concentrations exceeding applicable Florida Department of Environmental Protection (FDEP) Chapter 62-777, Florida Administrative Code, Natural Attenuation Default Concentrations (NADCs). This report presents a summary of the third year of OM&M activities conducted between June 2014 and September 2015.

  7. 2. Oblique view of EPA Farm Lab Building 1506 (with ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Oblique view of EPA Farm Lab Building 15-06 (with slaughter addition at far left), facing southwest - Nevada Test Site, Environmental Protection Agency Farm, Laboratory Building, Area 15, Yucca Flat, 10-2 Road near Circle Road, Mercury, Nye County, NV

  8. Problems Related to the Siting of the Laboratory Building for Civil Engineering Department at the University of Warmia and Mazury in Olsztyn, Poland

    NASA Astrophysics Data System (ADS)

    Zagroba, Marek

    2016-10-01

    This paper deals with the conditions underlying and the problems arising from the siting of a building with specialist laboratories in a developed part of the university campus in Olsztyn, Poland. The topography of the terrain and the need to house civil engineering laboratories in the planned building had an immense impact on the shape of the building and consequently on its foundations, whose dimensions responded to the ground conditions and the specification of various loads they would have to support, including the equipment for the laboratories. The siting of a building as a step in the construction process entails several problems, which are first taken into consideration at the stage of making preliminary concept plans and are subsequently verified while working on the final construction plan. The required information included geotechnical documentation, survey of the ground conditions and the data regarding the predicted loads on the building, necessary to select the right type of foundations. All these problems grow in importance when dealing with such unique buildings like the discussed example of a laboratory building for the Civil Engineering Department, built on a site within a conservation zone on the campus of the University of Warmia and Mazury in Olsztyn, Poland. The specific character of the building and the specialist equipment with which it was to be furnished (a resistance testing machine, a 17-meter-long wave flume) necessitated a series of analyses prior to the siting of the building and selecting suitable foundations. In turn, the fact that the new building was to be erected in the conservation zone meant that collaboration with the Heritage Conservation Office had to be undertaken at the stage of making the plan and continued during the construction works. The Heritage Officer's recommendations concerning the building's shape, divisions, dimensions, materials used, etc., created a situation where the team of designers and architects had to

  9. Black Maria Reconstruction (left foreground); Building No. 1; Main Building; ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Black Maria Reconstruction (left foreground); Building No. 1; Main Building; Edison Storage Battery Building (right background) - Thomas A. Edison Laboratories, Main Street & Lakeside Avenue, West Orange, Essex County, NJ

  10. 10. BOILER #16 (BUILDING L8) TO LEFT, L.P. AND H.P. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. BOILER #16 (BUILDING L8) TO LEFT, L.P. AND H.P. BOILER ROOMS (BUILDINGS L4 AND L2) TO RIGHT, AND STEPHENS SUBSTATION (BUILDING L6) IN BACKGROUND, FROM THE ROOF OF THE POWERHOUSE EXTENSION (BUILDING L5) - Portland General Electric Company, Station "L", 1841 Southeast Water Street, Portland, Multnomah County, OR

  11. 10. Historic American Buildings Survey PEN & INK DRAWING BY ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey PEN & INK DRAWING BY FRANCIS H. CRUESS (original drawing & full-size reproducible on file) after and oil painting of ca. 1860 - Johannes Luyster House, Laurel Avenue & Middleton Road, Holland, Monmouth County, NJ

  12. 10. Historic American Buildings Survey Photocopy c. 1923 from J. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey Photocopy c. 1923 from J. J. Glessner The Story of a House DINING ROOM: WEST AND NORTH SIDES - John J. Glessner House, 1800 South Prairie Avenue, Chicago, Cook County, IL

  13. 10. Historic American Buildings Survey, Photographed by H. F. Withey, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey, Photographed by H. F. Withey, April 4th, 1934 DETAIL OF SOUTH PORCH, EAST END. - Mrs. A. L. M. Vhay House, 835 Leguna Street, Santa Barbara, Santa Barbara County, CA

  14. 78 FR 76731 - Special Conditions: Boeing Model 777-200, -300, and -300ER Series Airplanes; Rechargeable Lithium...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-19

    ... Series Airplanes; Rechargeable Lithium Ion Batteries and Battery Systems AGENCY: Federal Aviation... lithium ion batteries and battery system that will be used on an International Communications Group (ICG... installing equipment that uses rechargeable lithium ion batteries and battery systems in the Boeing Model 777...

  15. 5. View of interior, EPA Farm Lab Building 1506 slaughter ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. View of interior, EPA Farm Lab Building 15-06 slaughter addition (featuring cold slaughter area), facing north-northeast - Nevada Test Site, Environmental Protection Agency Farm, Laboratory Building, Area 15, Yucca Flat, 10-2 Road near Circle Road, Mercury, Nye County, NV

  16. Scoring life insurance applicants' laboratory results, blood pressure and build to predict all-cause mortality risk.

    PubMed

    Fulks, Michael; Stout, Robert L; Dolan, Vera F

    2012-01-01

    Evaluate the degree of medium to longer term mortality prediction possible from a scoring system covering all laboratory testing used for life insurance applicants, as well as blood pressure and build measurements. Using the results of testing for life insurance applicants who reported a Social Security number in conjunction with the Social Security Death Master File, the mortality associated with each test result was defined by age and sex. The individual mortality scores for each test were combined for each individual and a composite mortality risk score was developed. This score was then tested against the insurance applicant dataset to evaluate its ability to discriminate risk across age and sex. The composite risk score was highly predictive of all-cause mortality risk in a linear manner from the best to worst quintile of scores in a nearly identical fashion for each sex and decade of age. Laboratory studies, blood pressure and build from life insurance applicants can be used to create scoring that predicts all-cause mortality across age and sex. Such an approach may hold promise for preventative health screening as well.

  17. 10. Historic American Buildings Survey, George J. Vaillancourt, Photographer, 1940 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey, George J. Vaillancourt, Photographer, 1940 VIEW OF 'GREAT SUMMER BEAM' (FIRST STORY). - Thomas Fenner House, 1538 Plainfield Street, Thornton, Providence County, RI

  18. 3. View of EPA Farm Lab Building 1506 (with sliding ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. View of EPA Farm Lab Building 15-06 (with sliding doors open to slaughter addition) and Sioux silo, facing north-northwest - Nevada Test Site, Environmental Protection Agency Farm, Laboratory Building, Area 15, Yucca Flat, 10-2 Road near Circle Road, Mercury, Nye County, NV

  19. General view of buildings: Building No. 6 with smokestack (left ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    General view of buildings: Building No. 6 with smokestack (left foreground); Building No. 5 (left background); Base of Water Tower (right foreground); Buildings 4, 3, 2, 1 (center foreground to background) - Thomas A. Edison Laboratories, Main Street & Lakeside Avenue, West Orange, Essex County, NJ

  20. 10. Historic American Buildings Survey W. N. Manning, Photographer, January ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey W. N. Manning, Photographer, January 26, 1935 HALL AND STAIRWAY FROM FRONT DOOR - Freeman-Caver-Christian House, Upper Friendship Road, Oxford, Calhoun County, AL

  1. 10. Historic American Buildings Survey Alex Bush, Photographer, September 12, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey Alex Bush, Photographer, September 12, 1935 OLD SLAVE HOUSE, SMOKE HOUSE IN REAR - Greenlawn, U.S. Highway 431 (Memorial Parkway), Huntsville, Madison County, AL

  2. 10. Historic American Buildings Survey Society of California Pioneers Original: ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey Society of California Pioneers Original: 1860's Re-photo: January 1940 CONVENTO - Mission San Jose de Guadalupe, Mission & Washington Boulevards, Fremont, Alameda County, CA

  3. 10. Historic American Buildings Survey Theodore Webb, Photographer, Mar. 16, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey Theodore Webb, Photographer, Mar. 16, 1934 CORNICE DETAIL, WING (FROM MAIN ROOF) - Kentucky School for the Blind, 1867 Frankfort Avenue, Louisville, Jefferson County, KY

  4. 10. Historic American Buildings Survey, James C. Massey, Photographer November, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey, James C. Massey, Photographer November, 1959 DETAIL OF COLUMN CAPITAL, FRONT ALCOVE. - Provident Life & Trust Company Bank, 407-409 Chestnut Street, Philadelphia, Philadelphia County, PA

  5. 10. June 25, 1963 SEED BUILDING UNDER CONSTRUCTION Looking northeast ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. June 25, 1963 SEED BUILDING UNDER CONSTRUCTION Looking northeast showing west wall of Machinery Shed - Tucson Plant Material Center, Machinery Shed, 3241 North Romero Road, Tucson, Pima County, AZ

  6. 10. VIEW OF BUILDING 6. INTERIOR OF SINGLE STORY SECTION ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. VIEW OF BUILDING 6. INTERIOR OF SINGLE STORY SECTION AT NORTH END. FACING SOUTHEAST. - Winehaven, Storage Cellar & Fermentation Room, Point Molate Naval Fuel Depot, Richmond, Contra Costa County, CA

  7. 10. Historic American Buildings Survey Alex Bush, Photographer, October 15, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey Alex Bush, Photographer, October 15, 1935 DETAIL OF REAR S. E. GROUND FLOOR WINDOW - University of Alabama, President's House, University Boulevard, Tuscaloosa, Tuscaloosa County, AL

  8. 4. Oblique view of EPA Farm Lab Building 1506 (with ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. Oblique view of EPA Farm Lab Building 15-06 (with sliding door open to milking area), Sioux silo and slaughter addition, facing northeast - Nevada Test Site, Environmental Protection Agency Farm, Laboratory Building, Area 15, Yucca Flat, 10-2 Road near Circle Road, Mercury, Nye County, NV

  9. 16. VIEW OF THE STATIONARY OPERATING ENGINEER CONTROL PANEL INSTALLATION. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. VIEW OF THE STATIONARY OPERATING ENGINEER CONTROL PANEL INSTALLATION. THE PANEL CONTROLS AIR-HANDLING EQUIPMENT AND AIR PRESSURE WITHIN THE BUILDING. (10/6/69) - Rocky Flats Plant, Plutonium Manufacturing Facility, North-central section of Plant, just south of Building 776/777, Golden, Jefferson County, CO

  10. Building Your Career in a Government Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, Kelly O.; Snyder, Seth W.

    In this chapter we cover an eclectic mix of topics with the intent of providing you the lessons that we believe will aid in your success in a government laboratory research environment, though of course most of these cross into other sorts of work environments as well: • Communication techniques • Working in a team • Personal development activities • Following the rules • The business of research • Your personal brand

  11. 10. Historic American Buildings Survey E. W. Russell, Photographer, June ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey E. W. Russell, Photographer, June 17, 1937 FIREPLACE AND MANTEL. SOUTH WALL OF SOUTH FRONT ROOM, FIRST STORY. - Wewoka, Riser Mill Road, Sylacauga, Talladega County, AL

  12. 10. Historic American Buildings Survey Arthur C. Haskell, Photographer Aug. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey Arthur C. Haskell, Photographer Aug. 30, 1938 (j) INT.-MANTEL, SOUTHWEST ROOM, 2nd. FLOOR - Captain William Wildes House, 872 Commercial Street, Weymouth, Norfolk County, MA

  13. 10. CUT OF THE CHURCH BUILDING AS IT APPEARED ON ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. CUT OF THE CHURCH BUILDING AS IT APPEARED ON THE PRINTED PROGRAM OF THE JANUARY 1, 1893 DEDICATION SERVICE. - Second Presbyterian Church, Pontatoc Avenue & Hernando Street, Memphis, Shelby County, TN

  14. 10. Historic American Buildings Survey W. N. Manning, Photographer, July ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey W. N. Manning, Photographer, July 18, 1935 VIEW IN HALL, TOWARD FRONT OF HOUSE - Crowell-Cantey-Alexander House, State Road 165, Fort Mitchell, Russell County, AL

  15. 10. Historic American Buildings Survey Alex Bush, Photographer, March 30, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey Alex Bush, Photographer, March 30, 1936 MANTEL AND WINDOW TREATMENT IN E. WALL OF LIVING ROOM - Southern University, Chancellor's House, College Street, Greensboro, Hale County, AL

  16. 45 CFR 2102.10 - Timing, scope and content of submissions for proposed projects involving land, buildings, or...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... proposed projects involving land, buildings, or other structures. 2102.10 Section 2102.10 Public Welfare... for proposed projects involving land, buildings, or other structures. (a) A party proposing a project... historical information about the building or other structure to be altered or razed; (ii) The identity of the...

  17. 10. Historic American Buildings Survey, Roy Oglesby, Photographer July 9, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey, Roy Oglesby, Photographer July 9, 1947 DETAIL OF WINDOW #6, SOUTH ELEVATION OF CHAPEL. - Old Fort Randall Church, Right Bank, Missouri River, Pickstown, Charles Mix County, SD

  18. 10. SAC command center, main operations area, underground structure, building ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. SAC command center, main operations area, underground structure, building 501, circa 1980 - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Command Center, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  19. 5. Historic American Buildings Survey James Rainey, Photographer May 10, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. Historic American Buildings Survey James Rainey, Photographer May 10, 1936 GRINDING PLATFORM, VIEW OF INTERIOR LOOKING WEST - Old Town Mill, Mill Brook, near Mill Street, New London, New London County, CT

  20. 10. Historic American Buildings Survey E. W. Russell, Photographer, August ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey E. W. Russell, Photographer, August 4, 1936 INTERIOR VIEW OF WINDOW AND COLUMN UNDER SIDE BALCONY - Government Street Presbyterian Church, Government & Jackson Streets, Mobile, Mobile County, AL

  1. 10. Historic American Buildings Survey Arthur C. Haskell, Photographer Feb. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey Arthur C. Haskell, Photographer Feb. 15, 1938 (o) INT.- WALL PAPER, SOUTHEAST ROOM, 1st. FLOOR - Major Israel Forster House, State Route 127, Manchester, Essex County, MA

  2. Promoting, building and sustaining a regional laboratory network in a changing environment.

    PubMed

    More, J D; Sengupta, S K; Manley, P N

    2000-01-01

    The Queen's University Department of Pathology and its affiliated hospital laboratories (Kingston, Canada) have operated a successful laboratory outreach program for more than a decade in Southeastern Ontario. The outreach program provides high quality reference testing and technical and professional expertise in laboratory medicine to largely rural and small urban community hospitals. As a consequence of dramatic cuts to the publicly funded health-care system in the Province of Ontario, the environment in which laboratory medicine is practiced has altered irrevocably. This article discusses some of the difficult internal and external challenges faced by the outreach program within the region and how they were effectively managed, not only to maintain but to enhance the program's services. The result has been a continued improvement in the quality of laboratory services in the region with significantly increased cost-effectiveness, largely through reengineering and consolidation.

  3. 1. Exterior view of Signal Transfer Building (T28A), looking southwest. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Exterior view of Signal Transfer Building (T-28A), looking southwest. This structure houses controls for propellant transfer, instrumentation for testing, test data transmission receivers, data verification equipment, and centralized utilities for the Systems Integration Laboratory complex. The gantries of the Systems Integration Laboratory Building (T-28) are visible to the rear of this structure. - Air Force Plant PJKS, Systems Integration Laboratory, Signal Transfer Building, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  4. VIEW OF BUILDING 126, LOOKING NORTH. BUILDING 126, THE SOURCE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF BUILDING 126, LOOKING NORTH. BUILDING 126, THE SOURCE CALIBRATION LABORATORY, WAS USED TO EXPOSE AND CALIBRATE RADIATION DETECTION DEVICES, INCLUDING THERMOLUMINESCENT DOSIMETERS, WORN BY EMPLOYEES TO DETECT RADIATION EXPOSURE - Rocky Flats Plant, Source Calibration Laboratory, Between Second & Third Streets & Central & Cedar Avenues, Golden, Jefferson County, CO

  5. 10. Historic American Buildings Survey Society of California Pioneers From ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey Society of California Pioneers From Vischer Drawing REAR VIEW OF MISSION About 1870 - Mission San Carlos Borromeo, Rio Road & Lausen Drive, Carmel-by-the-Sea, Monterey County, CA

  6. 10. Historic American Buildings Survey, N. E. Baldwin, Photographer November ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey, N. E. Baldwin, Photographer November 1939, COOLING ROOM, Gift of New York State Department of Education. - Shaker North Family, Dwelling House, Shaker Road, New Lebanon, Columbia County, NY

  7. 10. Historic American Buildings Survey CFA Staff, Photographer, 1972 FIRST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey CFA Staff, Photographer, 1972 FIRST- SECOND- FLOOR PLAN J. L. S. Jennings, Jr., Delineator - Edward H. Everett House, 1606 Twenty-third Street Northwest, Washington, District of Columbia, DC

  8. 10. Historic American Buildings Survey Society of California Pioneers Original: ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey Society of California Pioneers Original: About 1870's Re- photo: January 1940 VIEW FROM SOUTHEAST - Mission San Antonio de Padua, Hunter Liggett Military Reservation, Jolon, Monterey County, CA

  9. 10. Historic American Buildings Survey W. N. Manning, Photographer, May ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey W. N. Manning, Photographer, May 18, 1935 TREATMENT OF DOUBLE DOOR FROM PARLOR TO SITTING ROOM, S. W. ROOM - Elmoreland, U.S. Highway 241, Glenville, Russell County, AL

  10. 10. Historic American Buildings Survey Frances Rand Smith Collection California ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey Frances Rand Smith Collection California Historical Society Original: About 1890 Re-photo: January 1940 SECOND FRAME CHURCH REPLACING MISSION (1890) - Mission San Rafael Archangel, San Rafael, Marin County, CA

  11. 10. WEST WALL OF POWER PLANT BUILDING LOOKING EAST SOUTHEAST. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. WEST WALL OF POWER PLANT BUILDING LOOKING EAST SOUTHEAST. - Potomac Power Plant, On West Virginia Shore of Potomac River, about 1 mile upriver from confluence with Shenandoah River, Harpers Ferry, Jefferson County, WV

  12. 10. Historic American Buildings Survey W. N. Manning, Photographer, October ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey W. N. Manning, Photographer, October 23, 1935 RIGHT WING OF CROSS-HALL COMING OUT OF FRONT DOOR - McBryde-Screws-Tyson House, 423 Mildred Street, Montgomery, Montgomery County, AL

  13. 10. Historic American Buildings Survey Alex Bush, Photographer, March 24, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey Alex Bush, Photographer, March 24, 1937 VIEW IN FRONT OF MAIN HALL, SECOND FLOOR - Colonel Joseph R. Hawthorne House, Broad Street (County Road 59), Pine Apple, Wilcox County, AL

  14. 10. LAUNCH CONTROL SUPPORT BUILDING. INTERIOR OF BEDROOM. VIEW TO ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. LAUNCH CONTROL SUPPORT BUILDING. INTERIOR OF BEDROOM. VIEW TO SOUTH. - Minuteman III ICBM Launch Control Facility November-1, 1.5 miles North of New Raymer & State Highway 14, New Raymer, Weld County, CO

  15. 10. Historic American Buildings Survey John O. Brostrup, Photographer October ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey John O. Brostrup, Photographer October 19, 1936 1:40 P. M. DETAIL OF MUSIC CLOSET, MUSIC ROOM, NORTHEAST CORNER. - Grayhaven Manor, State Route 109 Vicinity, Poolesville, Montgomery County, MD

  16. 10. EAST SIDE OF BUILDING, LOOKING NORTH, TO LEFT FURNACES ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. EAST SIDE OF BUILDING, LOOKING NORTH, TO LEFT FURNACES WITH MAIN WATER HOLDING TANKS ABOVE - Portland General Electric Company, Station "L", L.P. Boiler Room, 1841 Southeast Water Street, Portland, Multnomah County, OR

  17. 10. Historic American Buildings Survey Alex Bush, Photographer, October 8, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey Alex Bush, Photographer, October 8, 1936 MANTEL AND WINDOW IN EAST WALL OF NORTH EAST ROOM, SECOND FLOOR - Judge W. E. Torbert House, 1101 South Street, Greensboro, Hale County, AL

  18. 10. VIEW TO SOUTHEAST, SAMPLING BUILDING, FOUNDATION, WATER TOWER, AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. VIEW TO SOUTHEAST, SAMPLING BUILDING, FOUNDATION, WATER TOWER, AND SKINNER SALT ROASTERS. - Vanadium Corporation of America (VCA) Naturita Mill, 3 miles Northwest of Naturita, between Highway 141 & San Miguel River, Naturita, Montrose County, CO

  19. 10. BUILDING: SECOND FLOOR (East Section), VIEW SOUTH: EAST, SOUTH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. BUILDING: SECOND FLOOR (East Section), VIEW SOUTH: EAST, SOUTH AND WEST WALLS OF COLD STORAGE, ALSO SHOWING REMNANTS OF COOLING PIPES - Boston Beer Company, 225-249 West Second Street, South Boston, Suffolk County, MA

  20. 10. Historic American Buildings Survey, Arthur C. Haskell, Photographer. Dec. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey, Arthur C. Haskell, Photographer. Dec. 1934. (e) After-- Looking south along Summer St. from Merrimack St. - Highway Cut-off Demolition Area, Summer, Winter, High & Merrimac Streets, Newburyport, Essex County, MA

  1. 12. Historic American Buildings Survey Joseph Hill, Photographer July 10, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. Historic American Buildings Survey Joseph Hill, Photographer July 10, 1936 SOUTH ELEVATION (Copied from student's drawing, Dept. of Architecture, Armour Institute of Technology. Chicago) - Keating House, U.S. Highway 430, Fayville, Alexander County, IL

  2. Laboratory Animal Facilities. Laboratory Design Notes.

    ERIC Educational Resources Information Center

    Jonas, Albert M.

    1965-01-01

    Design of laboratory animal facilities must be functional. Accordingly, the designer should be aware of the complex nature of animal research and specifically the type of animal research which will be conducted in a new facility. The building of animal-care facilities in research institutions requires special knowledge in laboratory animal…

  3. 4. Exterior view of Components Test Laboratory (T27), looking northeast. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. Exterior view of Components Test Laboratory (T-27), looking northeast. The building wing on the left houses Test Cell 8 (oxidizer) and the oxidizer storage pit or vault, and that on the right houses Test Cell 10 (environmental). - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  4. 5. Exterior view of Components Test Laboratory (T27), looking northwest. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. Exterior view of Components Test Laboratory (T-27), looking northwest. The building wing on the left houses Test Cell 10 (environmental), and that on the right houses Test Cell 9 (fuel) and the fuel storage pit or vault. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  5. 10. Historic American Buildings Survey John O. Brostrup, Photographer May ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey John O. Brostrup, Photographer May 6, 1937 3:15 P.M. DETAIL OF DOOR, ENTRANCE HALL, SOUTHEAST WALL. - Holly Hill, Southeast of Friendship off MD 631, Friendship, Anne Arundel County, MD

  6. Isolation and Genetic Analysis of an Environmental Bacteriophage: A 10-Session Laboratory Series in Molecular Virology

    ERIC Educational Resources Information Center

    Williamson, Ryan P.; Barker, Brent T.; Drammeh, Hamidou; Scott, Jefferson; Lin, Joseph

    2014-01-01

    Bacterial viruses, otherwise known as bacteriophage (or phage), are some of the most abundant viruses found in the environment. They can be easily isolated from water or soil and are ideal for use in laboratory classrooms due to their ease of culture and inherent safety. Here, we describe a series of 10 laboratory exercises where students collect,…

  7. Laboratory capacity building for the International Health Regulations (IHR[2005]) in resource-poor countries: the experience of the African Field Epidemiology Network (AFENET).

    PubMed

    Masanza, Monica Musenero; Nqobile, Ndlovu; Mukanga, David; Gitta, Sheba Nakacubo

    2010-12-03

    Laboratory is one of the core capacities that countries must develop for the implementation of the International Health Regulations (IHR[2005]) since laboratory services play a major role in all the key processes of detection, assessment, response, notification, and monitoring of events. While developed countries easily adapt their well-organized routine laboratory services, resource-limited countries need considerable capacity building as many gaps still exist. In this paper, we discuss some of the efforts made by the African Field Epidemiology Network (AFENET) in supporting laboratory capacity development in the Africa region. The efforts range from promoting graduate level training programs to building advanced technical, managerial and leadership skills to in-service short course training for peripheral laboratory staff. A number of specific projects focus on external quality assurance, basic laboratory information systems, strengthening laboratory management towards accreditation, equipment calibration, harmonization of training materials, networking and provision of pre-packaged laboratory kits to support outbreak investigation. Available evidence indicates a positive effect of these efforts on laboratory capacity in the region. However, many opportunities exist, especially to support the roll-out of these projects as well as attending to some additional critical areas such as biosafety and biosecuity. We conclude that AFENET's approach of strengthening national and sub-national systems provide a model that could be adopted in resource-limited settings such as sub-Saharan Africa.

  8. Earthquakes and building design: a primer for the laboratory animal professional.

    PubMed

    Vogelweid, Catherine M; Hill, James B; Shea, Robert A; Johnson, Daniel B

    2005-01-01

    Earthquakes can occur in most regions of the United States, so it might be necessary to reinforce vulnerable animal facilities to better protect research animals during these unpredictable events. A risk analysis should include an evaluation of the seismic hazard risk at the proposed building site balanced against the estimated consequences of losses. Risk analysis can help in better justifying and recommending to building owners the costs of incorporating additional seismic reinforcements. The planning team needs to specify the level of post-earthquake building function that is desired in the facility, and then design the facility to it.

  9. 21. Photographic contact print from a 8x10 original negative. (Original ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    21. Photographic contact print from a 8x10 original negative. (Original drawing located on abandoned NASA site, currently owned by the City of Downey, Downey, California). 1954 NORTH AMERICAN AVIATION BUILDING 41 CONSTRUCTION LAYOUT. - NASA Industrial Plant, Missile Research Laboratory, 12214 Lakewood Boulevard, Downey, Los Angeles County, CA

  10. Historic Context and Building Assessments for the Lawrence Livermore National Laboratory Built Environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ullrich, R. A.; Sullivan, M. A.

    2007-09-14

    This document was prepared to support u.s. Department of Energy / National Nuclear Security Agency (DOE/NNSA) compliance with Sections 106 and 110 of the National Historic Preservation Act (NHPA). Lawrence Livermore National Laboratory (LLNL) is a DOE/NNSA laboratory and is engaged in determining the historic status of its properties at both its main site in Livermore, California, and Site 300, its test site located eleven miles from the main site. LLNL contracted with the authors via Sandia National Laboratories (SNL) to prepare a historic context statement for properties at both sites and to provide assessments of those properties of potentialmore » historic interest. The report contains an extensive historic context statement and the assessments of individual properties and groups of properties determined, via criteria established in the context statement, to be of potential interest. The historic context statement addresses the four contexts within which LLNL falls: Local History, World War II History (WWII), Cold War History, and Post-Cold War History. Appropriate historic preservation themes relevant to LLNL's history are delineated within each context. In addition, thresholds are identified for historic significance within each of the contexts based on the explication and understanding of the Secretary of the Interior's Guidelines for determining eligibility for the National Register of Historic Places. The report identifies specific research areas and events in LLNL's history that are of interest and the portions of the built environment in which they occurred. Based on that discussion, properties of potential interest are identified and assessments of them are provided. Twenty individual buildings and three areas of potential historic interest were assessed. The final recommendation is that, of these, LLNL has five individual historic buildings, two sets of historic objects, and two historic districts eligible for the National Register. All are eligible

  11. 10. Historic American Buildings Survey Lester Jones, Photographer August 24, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey Lester Jones, Photographer August 24, 1940 INTERESTING ARCHES, SECOND FLOOR - Shaker Centre Family Dwelling House (Third), North side of Village Road, North of Route 68 & State Route 33, Shakertown, Mercer County, KY

  12. Postirradiation Testing Laboratory (327 Building)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kammenzind, D.E.

    A Standards/Requirements Identification Document (S/RID) is the total list of the Environment, Safety and Health (ES and H) requirements to be implemented by a site, facility, or activity. These requirements are appropriate to the life cycle phase to achieve an adequate level of protection for worker and public health and safety, and the environment during design, construction, operation, decontamination and decommissioning, and environmental restoration. S/RlDs are living documents, to be revised appropriately based on change in the site`s or facility`s mission or configuration, a change in the facility`s life cycle phase, or a change to the applicable standards/requirements. S/RIDs encompassmore » health and safety, environmental, and safety related safeguards and security (S and S) standards/requirements related to the functional areas listed in the US Department of Energy (DOE) Environment, Safety and Health Configuration Guide. The Fluor Daniel Hanford (FDH) Contract S/RID contains standards/requirements, applicable to FDH and FDH subcontractors, necessary for safe operation of Project Hanford Management Contract (PHMC) facilities, that are not the direct responsibility of the facility manager (e.g., a site-wide fire department). Facility S/RIDs contain standards/requirements applicable to a specific facility that are the direct responsibility of the facility manager. S/RlDs are prepared by those responsible for managing the operation of facilities or the conduct of activities that present a potential threat to the health and safety of workers, public, or the environment, including: Hazard Category 1 and 2 nuclear facilities and activities, as defined in DOE 5480.23. Selected Hazard Category 3 nuclear, and Low Hazard non-nuclear facilities and activities, as agreed upon by RL. The Postirradiation Testing Laboratory (PTL) S/RID contains standards/ requirements that are necessary for safe operation of the PTL facility, and other building/areas that are the

  13. 10. Historic American Buildings Survey Photocopy of Unsigned, Undated Drawing, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey Photocopy of Unsigned, Undated Drawing, Courtesy, The Cosmos Club PROPOSED FLOOR PLANS, 2121 MASSACHUSETTS AVENUE, N.W., BLUEPRINT #11, THIRD FLOOR PLAN - Townsend House, 2121 Massachusetts Avenue Northwest, Washington, District of Columbia, DC

  14. Building America Top Innovations 2013 Profile – Building America Solution Center

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2013-09-01

    This Top Innovation profile provides information about the Building America Solution Center created by Pacific Northwest National Laboratory, a web tool connecting users to thousands of pieces of building science information developed by DOE’s Building America research partners.

  15. 19 CFR 10.777 - Imported directly.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... ARTICLES CONDITIONALLY FREE, SUBJECT TO A REDUCED RATE, ETC. United States-Morocco Free Trade Agreement... bills, packing lists, commercial invoices, receiving and inventory records, and customs entry and exit...

  16. 10. Historic American Buildings Survey Photocopy of ink on linen ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey Photocopy of ink on linen drawing dated 1878, Longfellow & Clark, in possession of owner, 70 Sparks Street, Cambridge Street, Massachusetts FIRST FLOOR PLAN - Edward S. Dodge House, 70 Sparks Street, Cambridge, Middlesex County, MA

  17. JPL Administration Building

    NASA Image and Video Library

    2016-10-27

    This archival image was released as part of a gallery comparing JPL's past and present, commemorating the 80th anniversary of NASA's Jet Propulsion Laboratory on Oct. 31, 2016. The Administration Building of NASA's Jet Propulsion Laboratory (Building 180) is pictured in January 1965. What appears as a parking lot in this photograph later becomes "The Mall", a landscaped open-air gathering place. A small security control post can be seen at the left of the 1965 image. And Building 167, one of the lab's cafeterias, is on the right. http://photojournal.jpl.nasa.gov/catalog/PIA21121

  18. Exploration of a Buried Building Foundation and a Septic Tank Plume Dispersion Using a Laboratory-fabricated Resistivity Apparatus

    NASA Astrophysics Data System (ADS)

    Lachhab, A.; Stepanik, N.; Booterbaugh, A.

    2010-12-01

    In the following study, an electrical resistivity device was built and used in both a laboratory setup and in the field to accurately identify the location of a septic tank and the foundation of Gustavus Adolphus (GA); a building that was burned at Susquehanna University in 1964. The entire apparatus, which costs a fraction of the price of a typical electrical resistivity device, was tested for accuracy in the laboratory prior to its use in the field. The electrical resistivity apparatus consists of a deep-cycle twelve volt battery, an AC to DC inverter and two multimeters to measure the potential and the current intensity from four linear electrodes via a wireless data transmission system. This apparatus was constructed by using basic inexpensive electrical and electronic equipments. The recorded potential and current values were used to calculate the apparent resistivity of different materials adopting the Wenner array for both investigations. Several tests were performed on the tabletop bench, producing consistent results when applied to find small bricks structures with different geometrical arrangement buried under a mixed sand-soil formation. The apparatus was also used to investigate a subsurface salty water plume in the same formation. The horizontal resistivity profile obtained over the vertical small brick wall matched the theoretical apparent resistivity of resistivity versus displacement on a vertical dike in a homogeneous material. In addition, the two-dimensional resistivity profile replicate the salty plume size conformably. Following the success on the small-scale laboratory tabletop bench, the electrical resistivity apparatus was implemented in the field to explore the foundation of GA in one location and the septic tank in another. An array of transects were performed, analyzed and plotted using MATLAB. The three dimensional contours of apparent resistivity depicted exactly the locations of the buried foundation walls, the septic tank and the

  19. 10. Historic American Buildings Survey John N. DeHaas, Jr., Photographer ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey John N. DeHaas, Jr., Photographer August 1963 VIEW OF HAND CARVED CEILING PANEL - Sacred Heart Mission, Interstate 90 & Interchange 39, Cataldo, Shoshone County, ID

  20. 10. Historic American Buildings Survey Russell Jones, Photographer April 1959 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey Russell Jones, Photographer April 1959 GENERAL VIEW FROM THE SOUTH - Southeast Area Survey, 101 & 122-124 Carroll Street (House), 1008 Potomac Street (House), Canal Street at Independence Avenue (Row House), 1016-1018 Potomac Street (House), Washington, District of Columbia, DC

  1. 10. View inside Building 802, the "Sitting Area" looking from ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. View inside Building 802, the "Sitting Area" looking from the "Control Area" towards the doors to the "Sleeping Quarters", facing south. - Naval Air Station Fallon, 100-man Fallout Shelter, 800 Complex, off Carson Road near intersection of Pasture & Berney Roads, Fallon, Churchill County, NV

  2. 10. INTERIOR OF THE VERTICAL FURNACE BUILDING OF MACHINE SHOP ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. INTERIOR OF THE VERTICAL FURNACE BUILDING OF MACHINE SHOP No. 2. STRUCTURE IN THE FOREGROUND IS THE UPENDER. THE QUENCH TOWER AND FURNACES ARE IN THE BACKGROUND. - U.S. Steel Homestead Works, Machine Shop No. 2, Along Monongahela River, Homestead, Allegheny County, PA

  3. 10. Historic American Buildings Survey Photocopy BASEMENT PLAN, NORTH ELEVATION, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey Photocopy BASEMENT PLAN, NORTH ELEVATION, ARCHITECT'S ORIGINAL PLAN Restricted: Not to be reproduced without written permission from Beinecke Rare Books Library, Yale University, New Haven, Conn. - John Pitkin Norton House, 52 Hillhouse Avenue, New Haven, New Haven County, CT

  4. 31. SOUTH PLANT NORTHERN EDGE, SHOWING CELL BUILDING (BUILDING 242) ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    31. SOUTH PLANT NORTHERN EDGE, SHOWING CELL BUILDING (BUILDING 242) AT LEFT, LABORATORY (BUILDING 241) AT CENTER AND CAUSTIC FUSION PLANT (BUILDING 254) AT RIGHT. VIEW TO SOUTHWEST. - Rocky Mountain Arsenal, Bounded by Ninety-sixth Avenue & Fifty-sixth Avenue, Buckley Road, Quebec Street & Colorado Highway 2, Commerce City, Adams County, CO

  5. Implementation science: the laboratory as a command centre.

    PubMed

    Boeras, Debrah I; Nkengasong, John N; Peeling, Rosanna W

    2017-03-01

    Recent advances in point-of-care technologies to ensure universal access to affordable quality-assured diagnostics have the potential to transform patient management, surveillance programmes, and control of infectious diseases. Decentralization of testing can put tremendous stresses on fragile health systems if the laboratory is not involved in the planning, introduction, and scale-up strategies. The impact of investments in novel technologies can only be realized if these tests are evaluated, adopted, and scaled up within the healthcare system with appropriate planning and understanding of the local contexts in which these technologies will be used. In this digital age, the laboratory needs to take on the role of the Command Centre for technology introduction and implementation. Implementation science is needed to understand the political, cultural, economic, and behavioural context for technology introduction. The new paradigm should include: building a comprehensive system of laboratories and point-of-care testing sites to provide quality-assured diagnostic services with good laboratory-clinic interface to build trust in test results and linkage to care; building and coordinating a comprehensive national surveillance and communication system for disease control and global health emergencies; conducting research to monitor the impact of new tools and interventions on improving patient care.

  6. 10. Photocopy of c. 1893 photo, building just completed,view from ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Photocopy of c. 1893 photo, building just completed,view from south, photographer unknown,courtesy of Whatcom Museum of History and Art - New Whatcom City Hall, 121 Prospect Street, Bellingham, Whatcom County, WA

  7. Building Magnets at Brookhaven National Laboratory: A Condensed Account

    NASA Astrophysics Data System (ADS)

    Willen, Erich

    2017-09-01

    The development of superconducting wire and cable in the late twentieth century enabled high-field magnets and thus much higher beam-collision energies in accelerators. These higher collision energies have allowed experimentalists to probe further into the structure of matter at the most fundamental, subatomic level. The behavior of the early universe, where these high energies prevailed, and its evolution over time are the realm their experiments seek to investigate. The subject has aroused the curiosity of the public as well as scientists and has facilitated the support needed to build and operate such expensive machines and experiments. The path forward has not been easy, however. Success in most projects has been mixed with failure, progress with ineptitude. The building of high energy accelerators is mostly a story of capable people doing their best to develop new and unusual technology toward some defined goal, facing both success and failure along the way. It is also a story of administrative imperatives that had unpredictable effects on a project's success, depending mostly on the people in the administrative roles and the decisions that they made.

  8. 10. Historic American Buildings Survey Photocopy of Plate VIII (dated ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey Photocopy of Plate VIII (dated 1889) in John Calvin Stevens and Albert Winslow Cobb, Examples of American Domestic Architecture, New York, William T. Comstock, 1889 PLANS AND INTERIOR DETAILS, 1889 - John Calvin Stevens House, 52 Bowdoin Street, Portland, Cumberland County, ME

  9. A winning formula for new laboratories.

    PubMed

    Robinson, Tim

    2012-11-01

    High quality architecture and extensive stakeholder consultations have transformed the delivery of Laboratory Medicine within Sheffield Teaching Hospitals NHS Foundation Trust (NHSFT), explains Tim Robinson, senior architect at Race Cottam Associates, the architects on a scheme that has seen laboratory services from across the city consolidated within one modern, spacious, well-lit, and well-equipped building that should provide an extremely positive, 'future-proofed' working environment for staff.

  10. 43 CFR 3271.10 - What do I need to start preparing a site and building and testing a utilization facility on...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 43 Public Lands: Interior 2 2012-10-01 2012-10-01 false What do I need to start preparing a site and building and testing a utilization facility on Federal land leased for geothermal resources? 3271.10 Section 3271.10 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR...

  11. 43 CFR 3271.10 - What do I need to start preparing a site and building and testing a utilization facility on...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 43 Public Lands: Interior 2 2014-10-01 2014-10-01 false What do I need to start preparing a site and building and testing a utilization facility on Federal land leased for geothermal resources? 3271.10 Section 3271.10 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR...

  12. 43 CFR 3271.10 - What do I need to start preparing a site and building and testing a utilization facility on...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 43 Public Lands: Interior 2 2013-10-01 2013-10-01 false What do I need to start preparing a site and building and testing a utilization facility on Federal land leased for geothermal resources? 3271.10 Section 3271.10 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR...

  13. 43 CFR 3271.10 - What do I need to start preparing a site and building and testing a utilization facility on...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 2 2011-10-01 2011-10-01 false What do I need to start preparing a site and building and testing a utilization facility on Federal land leased for geothermal resources? 3271.10 Section 3271.10 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR...

  14. Correlation of VHI-10 to voice laboratory measurements across five common voice disorders.

    PubMed

    Gillespie, Amanda I; Gooding, William; Rosen, Clark; Gartner-Schmidt, Jackie

    2014-07-01

    To correlate change in Voice Handicap Index (VHI)-10 scores with corresponding voice laboratory measures across five voice disorders. Retrospective study. One hundred fifty patients aged >18 years with primary diagnosis of vocal fold lesions, primary muscle tension dysphonia-1, atrophy, unilateral vocal fold paralysis (UVFP), and scar. For each group, participants with the largest change in VHI-10 between two periods (TA and TB) were selected. The dates of the VHI-10 values were linked to corresponding acoustic/aerodynamic and audio-perceptual measures. Change in voice laboratory values were analyzed for correlation with each other and with VHI-10. VHI-10 scores were greater for patients with UVFP than other disorders. The only disorder-specific correlation between voice laboratory measure and VHI-10 was average phonatory airflow in speech for patients with UVFP. Average airflow in repeated phonemes was strongly correlated with average airflow in speech (r=0.75). Acoustic measures did not significantly change between time points. The lack of correlations between the VHI-10 change scores and voice laboratory measures may be due to differing constructs of each measure; namely, handicap versus physiological function. Presuming corroboration between these measures may be faulty. Average airflow in speech may be the most ecologically valid measure for patients with UVFP. Although aerodynamic measures changed between the time points, acoustic measures did not. Correlations to VHI-10 and change between time points may be found with other acoustic measures. Copyright © 2014 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  15. 10. Historic American Buildings Survey Russell Jones, Photographer April 1959 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey Russell Jones, Photographer April 1959 FRONT (NORTH) ELEVATION. 819 (LEFT) 817 (RIGHT) - Southeast Area Survey, 600-602 & 1100 G Street (House), 1002,1006 Eye Street (House), 808-810,812-814, & 1016 K Street (House), 817-819 L Street (House), Washington, District of Columbia, DC

  16. 10. VIEW OF PIPING. THE BUILDING HAD OVER 700 MILES ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. VIEW OF PIPING. THE BUILDING HAD OVER 700 MILES OF PIPING, OF WHICH 70 MILES WERE PLUTONIUM PROCESSING LINES. THESE PROCESS LINES RAN THROUGH WALLS AND TRAVERSED SEVERAL FLOORS. (6/29/78) - Rocky Flats Plant, Plutonium Recovery Facility, Northwest portion of Rocky Flats Plant, Golden, Jefferson County, CO

  17. 10. Historic American Buildings Survey Mr. Walker, Draftsman of Hebbard ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey Mr. Walker, Draftsman of Hebbard and Gill, Architects September 21, 1904 (Revised October 28, 1904) BLUEPRINT OF ORIGINAL DRAWING OF WEST ELEVATION From the Collection of the San Diego Historical Society - George W. Marston House, 3525 Seventh Avenue, San Diego, San Diego County, CA

  18. 10. VIEW OF THE ADDITION TO BUILDING 883, REFERRED TO ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. VIEW OF THE ADDITION TO BUILDING 883, REFERRED TO AS SIDE C. ARMOR PLATE MADE WITH DEPLETED URANIUM WAS HEATED IN A MOLTEN SALT BATH, THEN PROCESSED THROUGH THE ROLLING MILL TO FORM LARGE SHEETS. (9/16/85) - Rocky Flats Plant, Uranium Rolling & Forming Operations, Southeast section of plant, southeast quadrant of intersection of Central Avenue & Eighth Street, Golden, Jefferson County, CO

  19. Aerosol in selected laboratories at Faculty of Mechanical Engineering, Opole University of Technology

    NASA Astrophysics Data System (ADS)

    Olszowski, Tomasz

    2017-10-01

    The paper contains the results of a study into mass concentration of the dispersed aerosol fraction with the aerodynamic diameter of up to 2.5 and 10 micrometers. The study was conducted during classes with students participating in them in two laboratories located at Faculty of Mechanical Engineering, Opole University of Technology as well as outdoor outside the building. It was demonstrated that the values of the mass concentration of PM2.5 and PM10 measured in the laboratories differ considerably from the levels measured in the ambient air in the outdoor areas surrounding the faculty building. It was concluded that the diversity of PM2.5/PM10 ratio was greater in the laboratories. Direct correlation was not established between the concentrations of the particular PM fractions in the two investigated environments. It was demonstrated that there is a statistically significant relation between the concentration of PM2.5 and PM10 and the number of people present in the laboratory. The conducted cluster analysis led to the detection of the existence of dominant structures determining air quality parameters. For the analyzed case, endogenic factors are responsible for the aerosanitary condition. The study demonstrated that the evaluation of air quality needs to be performed individually for the specific rooms.

  20. [How do hospital clinical laboratories and laboratory testing companies cooperate and build reciprocal relations?].

    PubMed

    Kawano, Seiji

    2014-12-01

    As the 2nd Joint Symposium of the Japanese Society of Laboratory Medicine and the Japanese Association of Laboratory Pathologists, the symposium on clinical test out-sourcing and branch laboratories was held at the 60th General Meeting of the Japanese Society of Laboratory Medicine on November 2nd, 2013 in Kobe. For the symposium, we conducted a questionnaire survey on the usage of clinical test out-sourcing and the introduction of branch laboratories to clinical laboratories of Japanese university hospitals, both private and public, between July 25th and August 20th, 2013. Seventy-two hospitals responded to the questionnaire survey, consisting of 41 public medical school hospitals and 31 private ones. According to the survey, the selection of each clinical test for out-sourcing was mainly determined by the capacities of hospital clinical laboratories and their equipment, as well as the profitability of each test. The main concerns of clinical laboratory members of university hospitals involved the continuity of measurement principles, traceability, and standardization of reference values for each test. They strongly requested the interchangeability and computerization of test data between laboratory testing companies. A branch laboratory was introduced to six hospitals, all of which were private medical college hospitals, out of 72 university hospitals, and eight of the other hospitals were open to its introduction. The merits and demerits of introducing a branch laboratory were also discussed. (Review).

  1. Demand Shifting with Thermal Mass in Large Commercial Buildings in a California Hot Climate Zone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Peng; Yin, Rongxin; Brown, Carrie

    2009-06-01

    The potential for using building thermal mass for load shifting and peak energy demand reduction has been demonstrated in a number of simulation, laboratory, and field studies. Previous Lawrence Berkeley National Laboratory research has demonstrated that the approach is very effective in cool and moderately warm climate conditions (California Climate Zones 2-4). However, this method had not been tested in hotter climate zones. This project studied the potential of pre-cooling the building early in the morning and increasing temperature setpoints during peak hours to reduce cooling-related demand in two typical office buildings in hotter California climates ? one in Visaliamore » (CEC Climate Zone 13) and the other in San Bernardino (CEC Climate Zone 10). The conclusion of the work to date is that pre-cooling in hotter climates has similar potential to that seen previously in cool and moderate climates. All other factors being equal, results to date indicate that pre-cooling increases the depth (kW) and duration (kWh) of the possible demand shed of a given building. The effectiveness of night pre-cooling in typical office building under hot weather conditions is very limited. However, night pre-cooling is helpful for office buildings with an undersized HVAC system. Further work is required to duplicate the tests in other typical buildings and in other hot climate zones and prove that pre-cooling is truly effective.« less

  2. 10 CFR 434.506 - Use of the reference building to determine the energy cost budget.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Use of the reference building to determine the energy cost budget. 434.506 Section 434.506 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance...

  3. 10 CFR 434.504 - Use of the prototype building to determine the energy cost budget.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Use of the prototype building to determine the energy cost budget. 434.504 Section 434.504 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance...

  4. 10. Historic American Buildings Survey Russell Jones, Photographer April 1959 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey Russell Jones, Photographer April 1959 REAR(EAST) & LEFT ELEVATIONS FROM THE N. E. - Southeast Area Survey, Sixth & G Streets (Synagogue), 132-144 & 900-905 Eleventh Street (Row Houses), 215 Second Street (House), Seventh & G Streets (School), 214 First Street (House), Washington, District of Columbia, DC

  5. Quality assured measurements of animal building emissions: odor concentrations.

    PubMed

    Jacobson, Larry D; Hetchler, Brian P; Schmidt, David R; Nicolai, Richard E; Heber, Albert J; Ni, Ji-Qin; Hoff, Steven J; Koziel, Jacek A; Zhang, Yuanhui; Beasley, David B; Parker, David B

    2008-06-01

    Standard protocols for sampling and measuring odor emissions from livestock buildings are needed to guide scientists, consultants, regulators, and policy-makers. A federally funded, multistate project has conducted field studies in six states to measure emissions of odor, coarse particulate matter (PM(10)), total suspended particulates, hydrogen sulfide, ammonia, and carbon dioxide from swine and poultry production buildings. The focus of this paper is on the intermittent measurement of odor concentrations at nearly identical pairs of buildings in each state and on protocols to minimize variations in these measurements. Air was collected from pig and poultry barns in small (10 L) Tedlar bags through a gas sampling system located in an instrument trailer housing gas and dust analyzers. The samples were analyzed within 30 hr by a dynamic dilution forced-choice olfactometer (a dilution apparatus). The olfactometers (AC'SCENT International Olfactometer, St. Croix Sensory, Inc.) used by all participating laboratories meet the olfactometry standards (American Society for Testing and Materials and European Committee for Standardization [CEN]) in the United States and Europe. Trained panelists (four to eight) at each laboratory measured odor concentrations (dilution to thresholds [DT]) from the bag samples. Odor emissions were calculated by multiplying odor concentration differences between inlet and outlet air by standardized (20 degrees C and 1 atm) building airflow rates.

  6. PBF Cooling Tower (PER720) and its Auxiliary Building (PER625). Camera ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PBF Cooling Tower (PER-720) and its Auxiliary Building (PER-625). Camera facing west shows east facades. Center pipe carried secondary coolant water from reactor. Building to distributor basin. Date: August 2003. INEEL negative no. HD-35-10-1 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID

  7. FAST CHOPPER BUILDING, TRA665. CONTEXTUAL VIEW: CHOPPER BUILDING IN CENTER. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FAST CHOPPER BUILDING, TRA-665. CONTEXTUAL VIEW: CHOPPER BUILDING IN CENTER. MTR REACTOR SERVICES BUILDING,TRA-635, TO LEFT; MTR BUILDING TO RIGHT. CAMERA FACING WEST. INL NEGATIVE NO. HD42-1. Mike Crane, Photographer, 3/2004 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  8. Experiment definition phase shuttle laboratory LDRL-10.6 experiment

    NASA Technical Reports Server (NTRS)

    1975-01-01

    This report for the Experiment Definition Phase of the Shuttle Laboratory LDRL 10.6 Micrometer Experiment covers period 27 June through 26 September 1975. Activities during the fifth quarter included: (1) reevaluation of system obscuration ratio with a subsequent reduction of this ratio from 0.417 to 0.362, (2) completion of detail drawings for the 6X pre-expander, (3) completion of detail drawings for the nine mirrors that comprise pointing and tracking optomechanical subsystem, (4) continuation of detailing of mechanical portions of CMSS and modifications to accommodate new obscuration ratio, (5) qualitative operation of the optomechanical subsystem of the 10.6 um receiver achieved under experiment measurement task; receiver fully integrated and operation demonstrated over a 10 km experimental link, and (6) data collection task initiated to begin preparation of link analysis volumes.

  9. 10 CFR 431.18 - Testing laboratories.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Technology/National Voluntary Laboratory Accreditation Program (NIST/NVLAP); or (2) A laboratory accreditation body having a mutual recognition arrangement with NIST/NVLAP; or (3) An organization classified by the Department, pursuant to § 431.19, as an accreditation body. (b) NIST/NVLAP is under the auspices...

  10. 10 CFR 431.18 - Testing laboratories.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Technology/National Voluntary Laboratory Accreditation Program (NIST/NVLAP); or (2) A laboratory accreditation body having a mutual recognition arrangement with NIST/NVLAP; or (3) An organization classified by the Department, pursuant to § 431.19, as an accreditation body. (b) NIST/NVLAP is under the auspices...

  11. 10 CFR 431.18 - Testing laboratories.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Technology/National Voluntary Laboratory Accreditation Program (NIST/NVLAP); or (2) A laboratory accreditation body having a mutual recognition arrangement with NIST/NVLAP; or (3) An organization classified by the Department, pursuant to § 431.19, as an accreditation body. (b) NIST/NVLAP is under the auspices...

  12. 10 CFR 431.18 - Testing laboratories.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Technology/National Voluntary Laboratory Accreditation Program (NIST/NVLAP); or (2) A laboratory accreditation body having a mutual recognition arrangement with NIST/NVLAP; or (3) An organization classified by the Department, pursuant to § 431.19, as an accreditation body. (b) NIST/NVLAP is under the auspices...

  13. Synthesis of 10-Ethyl Flavin: A Multistep Synthesis Organic Chemistry Laboratory Experiment for Upper-Division Undergraduate Students

    ERIC Educational Resources Information Center

    Sichula, Vincent A.

    2015-01-01

    A multistep synthesis of 10-ethyl flavin was developed as an organic chemistry laboratory experiment for upper-division undergraduate students. Students synthesize 10-ethyl flavin as a bright yellow solid via a five-step sequence. The experiment introduces students to various hands-on experimental organic synthetic techniques, such as column…

  14. 138. ARAII Building ARA606 floor plan for remodel as Inel ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    138. ARA-II Building ARA-606 floor plan for remodel as Inel Welding Laboratory. Shows room divisions and welding stations to be installed. Aerojet Nuclear Company 1375-ARA-II-606-E-2. Date: June 1976. Ineel index code no. 070-0606-10-400-156552. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  15. 10. INTERIOR OF MAIN SECTION OF BUILDING 741/742. VIEW TO ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. INTERIOR OF MAIN SECTION OF BUILDING 741/742. VIEW TO WEST. - Rocky Mountain Arsenal, Refrigeration Napalm & Incendiary Bomb Warehouse-Bomb Filling, 825 feet South of December Seventh Avenue; 2425 feet East of D Street, Commerce City, Adams County, CO

  16. 10 CFR 431.18 - Testing laboratories.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... EQUIPMENT Electric Motors Test Procedures, Materials Incorporated and Methods of Determining Efficiency... Technology/National Voluntary Laboratory Accreditation Program (NIST/NVLAP); or (2) A laboratory... of the National Institute of Standards and Technology (NIST) which is part of the U.S. Department of...

  17. Fine pattern replication on 10 x 10-mm exposure area using ETS-1 laboratory tool in HIT

    NASA Astrophysics Data System (ADS)

    Hamamoto, K.; Watanabe, Takeo; Hada, Hideo; Komano, Hiroshi; Kishimura, Shinji; Okazaki, Shinji; Kinoshita, Hiroo

    2002-07-01

    Utilizing ETS-1 laboratory tool in Himeji Institute of Technology (HIT), as for the fine pattern replicated by using the Cr mask in static exposure, it is replicated in the exposure area of 10 mm by 2 mm in size that the line and space pattern width of 60 nm, the isolated line pattern width of 40 nm, and hole pattern width of 150 nm. According to the synchronous scanning of the mass and wafer with EUVL laboratory tool with reduction optical system which consisted of three-aspherical-mirror in the NewSUBARU facilities succeeded in the line of 60 nm and the space pattern formation in the exposure region of 10mm by 10mm. From the result of exposure characteristics for positive- tone resist for KrF and EB, KrF chemically amplified resist has better characteristics than EB chemically amplified resist.

  18. 10. View south of Arctic Observation Room (typical). Natick ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. View south of Arctic Observation Room (typical). - Natick Research & Development Laboratories, Climatic Chambers Building, U.S. Army Natick Research, Development & Engineering Center (NRDEC), Natick, Middlesex County, MA

  19. A corridor on the first floor of the building, looking ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A corridor on the first floor of the building, looking west, shows some of the typical interior finishes in this section. At the end of the hallway, the corridor turns right after entering the next adjacent structure - Department of Energy, Mound Facility, Electronics Laboratory Building (E Building), One Mound Road, Miamisburg, Montgomery County, OH

  20. Space Flight Support Building

    NASA Image and Video Library

    2016-10-27

    This archival image was released as part of a gallery comparing JPL’s past and present, commemorating the 80th anniversary of NASA’s Jet Propulsion Laboratory on Oct. 31, 2016. Building 264, also known as the Space Flight Support Building, hosts engineers supporting space missions in flight at NASA's Jet Propulsion Laboratory. It used to be just two stories, as seen in this image from January 1972, but then the Viking project to Mars needed more room. The building still serves the same function today, but now has eight floors. http://photojournal.jpl.nasa.gov/catalog/PIA21123

  1. 10. Historic American Buildings Survey, PHOTOCOPY OF PLAN PORTION OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey, PHOTOCOPY OF PLAN PORTION OF J.M. WHITAKER'S SURVEY OF THE LIPPITT MILL, SHEET NO. 15912 DATED MARCH 22, 1913. Blue line ozalid print in the collection of the Department of Civil and Mechanical Engineering, Museum of History and Technology, the Smithsonian Institution. - Lippitt Mill, 825 Main Street, West Warwick, Kent County, RI

  2. Dose profile modeling of Idaho National Laboratory's active neutron interrogation laboratory.

    PubMed

    Chichester, D L; Seabury, E H; Zabriskie, J M; Wharton, J; Caffrey, A J

    2009-06-01

    A new laboratory has been commissioned at Idaho National Laboratory for performing active neutron interrogation research and development. The facility is designed to provide radiation shielding for deuterium-tritium (DT) fusion (14.1 MeV) neutron generators (2 x 10(8) n/s), deuterium-deuterium (DD) fusion (2.5 MeV) neutron generators (1 x 10(7) n/s), and (252)Cf spontaneous fission neutron sources (6.96 x 10(7) n/s, 30 microg). Shielding at the laboratory is comprised of modular concrete shield blocks 0.76 m thick with tongue-in-groove features to prevent radiation streaming, arranged into one small and one large test vault. The larger vault is designed to allow operation of the DT generator and has walls 3.8m tall, an entrance maze, and a fully integrated electrical interlock system; the smaller test vault is designed for (252)Cf and DD neutron sources and has walls 1.9 m tall and a simple entrance maze. Both analytical calculations and numerical simulations were used in the design process for the building to assess the performance of the shielding walls and to ensure external dose rates are within required facility limits. Dose rate contour plots have been generated for the facility to visualize the effectiveness of the shield walls and entrance mazes and to illustrate the spatial profile of the radiation dose field above the facility and the effects of skyshine around the vaults.

  3. ETR HEAT EXCHANGER BUILDING, TRA644. METAL FRAME OF BUILDING GOES ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ETR HEAT EXCHANGER BUILDING, TRA-644. METAL FRAME OF BUILDING GOES UP IN BACKGROUND AS WORKERS PLACE A SECTION OF WATER LINE THAT WILL CARRY SECONDARY COOLANT BETWEEN HEAT EXCHANGER BUILDING AND THE COOLING TOWER. INL NEGATIVE NO. 56-2205. Jack L. Anderson, Photographer, 6/28/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  4. Conceptual design of new metrology laboratories for the National Physical Laboratory, United Kingdom

    NASA Astrophysics Data System (ADS)

    Manning, Christopher J.

    1994-10-01

    The National Physical Laboratory is planning to house the Division of Mechanical and Optical Metrology and the Division of Material Metrology in a new purpose built laboratory building on its site at Teddington, London, England. The scientific staff were involved in identifying and agreeing the vibration performance requirements of the conceptual design. This was complemented by an extensive surgery of vibration levels within the existing facilities and ambient vibration studies at the proposed site. At one end of the site there is significant vibration input from road traffic. Some of the test equipment is also in itself a source of vibration input. These factors, together with normal occupancy inputs, footfalls and door slams, and a highly serviced building led to vibration being dominant in influencing the structural form. The resulting structural concept comprises three separate structural elements for vibration and geotechnical reasons. The laboratories most sensitive to disturbance by vibration are located at the end of the site farthest from local roads on a massive ground bearing slab. Less sensitive laboratories and those containing vibration sources are located on a massive slab in deep, piled foundations. A common central plant area is located alongside on its own massive slab. Medium sensitivity laboratories and offices are located at first floor level on a reinforced concrete suspended floor of maximum stiffness per unit mass. The whole design has been such as to permit upgrading of areas, eg office to laboratory; laboratory to `high sensitivity' laboratory, to cater for changes in future use of the building.

  5. Analysis of environmental contamination resulting from catastrophic incidents: part 1. Building and sustaining capacity in laboratory networks.

    PubMed

    Magnuson, Matthew; Ernst, Hiba; Griggs, John; Fitz-James, Schatzi; Mapp, Latisha; Mullins, Marissa; Nichols, Tonya; Shah, Sanjiv; Smith, Terry; Hedrick, Elizabeth

    2014-11-01

    Catastrophic incidents, such as natural disasters, terrorist attacks, and industrial accidents, can occur suddenly and have high impact. However, they often occur at such a low frequency and in unpredictable locations that planning for the management of the consequences of a catastrophe can be difficult. For those catastrophes that result in the release of contaminants, the ability to analyze environmental samples is critical and contributes to the resilience of affected communities. Analyses of environmental samples are needed to make appropriate decisions about the course of action to restore the area affected by the contamination. Environmental samples range from soil, water, and air to vegetation, building materials, and debris. In addition, processes used to decontaminate any of these matrices may also generate wastewater and other materials that require analyses to determine the best course for proper disposal. This paper summarizes activities and programs the United States Environmental Protection Agency (USEPA) has implemented to ensure capability and capacity for the analysis of contaminated environmental samples following catastrophic incidents. USEPA's focus has been on building capability for a wide variety of contaminant classes and on ensuring national laboratory capacity for potential surges in the numbers of samples that could quickly exhaust the resources of local communities. USEPA's efforts have been designed to ensure a strong and resilient laboratory infrastructure in the United States to support communities as they respond to contamination incidents of any magnitude. The efforts include not only addressing technical issues related to the best-available methods for chemical, biological, and radiological contaminants, but also include addressing the challenges of coordination and administration of an efficient and effective response. Laboratory networks designed for responding to large scale contamination incidents can be sustained by applying

  6. 10 CFR 26.715 - Recordkeeping requirements for collection sites, licensee testing facilities, and laboratories...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Recordkeeping requirements for collection sites, licensee testing facilities, and laboratories certified by the Department of Health and Human Services. 26.715... laboratories certified by the Department of Health and Human Services. (a) Collection sites providing services...

  7. CONSTRUCTION PROGRESS PHOTO SHOWING EXCAVATION PIT FOR MAIN PROCESSING BUILDING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    CONSTRUCTION PROGRESS PHOTO SHOWING EXCAVATION PIT FOR MAIN PROCESSING BUILDING (CPP-601) LOOKING NORTHWEST. INL PHOTO NUMBER NRTS-50-885. Unknown Photographer, 10/30/1950 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID

  8. Building and Rebuilding: The National Public Health Laboratory Systems and Services Before and After the Earthquake and Cholera Epidemic, Haiti, 2009-2015.

    PubMed

    Jean Louis, Frantz; Buteau, Josiane; Boncy, Jacques; Anselme, Renette; Stanislas, Magalie; Nagel, Mary C; Juin, Stanley; Charles, Macarthur; Burris, Robert; Antoine, Eva; Yang, Chunfu; Kalou, Mireille; Vertefeuille, John; Marston, Barbara J; Lowrance, David W; Deyde, Varough

    2017-10-01

    Before the 2010 devastating earthquake and cholera outbreak, Haiti's public health laboratory systems were weak and services were limited. There was no national laboratory strategic plan and only minimal coordination across the laboratory network. Laboratory capacity was further weakened by the destruction of over 25 laboratories and testing sites at the departmental and peripheral levels and the loss of life among the laboratory health-care workers. However, since 2010, tremendous progress has been made in building stronger laboratory infrastructure and training a qualified public health laboratory workforce across the country, allowing for decentralization of access to quality-assured services. Major achievements include development and implementation of a national laboratory strategic plan with a formalized and strengthened laboratory network; introduction of automation of testing to ensure better quality of results and diversify the menu of tests to effectively respond to outbreaks; expansion of molecular testing for tuberculosis, human immunodeficiency virus, malaria, diarrheal and respiratory diseases; establishment of laboratory-based surveillance of epidemic-prone diseases; and improvement of the overall quality of testing. Nonetheless, the progress and gains made remain fragile and require the full ownership and continuous investment from the Haitian government to sustain these successes and achievements.

  9. CONSTRUCTION PROGRESS PHOTO SHOWING FUEL STORAGE BUILDING (CPP603) LOOKING NORTHWEST. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    CONSTRUCTION PROGRESS PHOTO SHOWING FUEL STORAGE BUILDING (CPP-603) LOOKING NORTHWEST. INL PHOTO NUMBER NRTS-50-895. Unknown Photographer, 10/30/1950 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID

  10. Laboratory investigation of monoclonal gammopathy during 10 years of screening in a general hospital.

    PubMed Central

    Malacrida, V; De Francesco, D; Banfi, G; Porta, F A; Riches, P G

    1987-01-01

    Protein electrophoresis was carried out on 102,000 samples from the patients of a district general hospital over 10 years, and a monoclonal protein was detected in 730 cases; of these, 114 could be classified as B cell malignancies and 261 as monoclonal gammopathy of undefined significance (MGUS). The various clinical and laboratory features of monoclonal gammopathy were examined with respect to distinguishing the malignant conditions from MGUS at first presentation. PMID:3114329

  11. Specific application for Oak Ridge National Laboratory dismantlement of Building 3004. Appendix A -- Quality assurance plan; Appendix B -- Records management plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    This quality assurance (QA) plan defines the QA requirements for the dismantlement and removal of Building 3004 at Oak Ridge National Laboratory (ORNL). The building is a four-story wooden trained structure with wooden siding, which resides approximately 150 ft west of the Bulk Shielding Reactor, and only several feet away from the visitors entrance to the Graphite Reactor museum. Complete descriptions and sketches are in the Performance Specification document for this project. This project is being conducted as a non-CERCLA maintenance action. This plan is an appendix to the QA plan for the ORNL Environmental Restoration (ER) Program. ORNL/ER-225, whichmore » is the source of the project QA requirements, tailors those QA requirements to the specific needs of this project as defined in ORNL/ER-225. Project-specific description and organization are also provided in this plan. Appendix B, Records Management Plan, is included.« less

  12. Space debris measurement program at Phillips Laboratory

    NASA Technical Reports Server (NTRS)

    Dao, Phan D.; Mcnutt, Ross T.

    1992-01-01

    Ground-based optical sensing was identified as a technique for measuring space debris complementary to radar in the critical debris size range of 1 to 10 cm. The Phillips Laboratory is building a staring optical sensor for space debris measurement and considering search and track optical measurement at additional sites. The staring sensor is implemented in collaboration with Wright Laboratory using the 2.5 m telescope at Wright Patterson AFB, Dayton, Ohio. The search and track sensor is designed to detect and track orbital debris in tasked orbits. A progress report and a discussion of sensor performance and search and track strategies will be given.

  13. Administration Building Lobby

    NASA Image and Video Library

    1943-07-21

    Receptionist Mary Louise Gosney enjoys the new Administration Building at the NACA’s Aircraft Engine Research Laboratory. The Administration Building, which was located near the front entrance to the laboratory, opened in December 1942. The staff, which had spent the previous year working in temporary offices inside the hangar, quickly occupied the new building. Lab director Raymond Sharp, the upper management team, and administrative staff had offices in the Administration Building. The structure also contained the lab’s library and auditorium. Gosney was a Chicago native who started at the lab in November 1941. Gosney’s services included welcoming visitors, arranging tours, and arranging interviews with staff members. Gosney’s “Lobby Lines” column in the lab’s newsletter Wing Tips noted the coming and goings of notable visitors and staff members. In addition to her role as receptionist, Gosney also served as the clearance officer. She would later head the entire Administrative Services Division.

  14. A Moveable Feast--A Progressive Approach to the Unit Operations Laboratory

    ERIC Educational Resources Information Center

    Conner, Wm. Curtis, Jr.; Hammond, Karl D.; Laurence, Robert L.

    2011-01-01

    The authors describe an alternative format for the senior laboratory in which students are allowed--indeed, expected--to communicate with previous groups and build on their results. The effect is a unit operations laboratory in which students are empowered to propose the experiments they wish to do and in which the cumulative experience of the…

  15. BUILDING PLANS OF FUEL STORAGE BUILDING (CPP603). INL DRAWING NUMBER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    BUILDING PLANS OF FUEL STORAGE BUILDING (CPP-603). INL DRAWING NUMBER 200-0603-61-299-103029. ALTERNATE ID NUMBER 542-31-B-21. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID

  16. Lab-on-a-Chip Design-Build Project with a Nanotechnology Component in a Freshman Engineering Course

    ERIC Educational Resources Information Center

    Allam, Yosef; Tomasko, David L.; Trott, Bruce; Schlosser, Phil; Yang, Yong; Wilson, Tiffany M.; Merrill, John

    2008-01-01

    A micromanufacturing lab-on-a-chip project with a nanotechnology component was introduced as an alternate laboratory in the required first-year engineering curriculum at The Ohio State University. Nanotechnology is introduced in related reading and laboratory tours as well as laboratory activities including a quarter-length design, build, and test…

  17. One wall of the original E Building is visible in ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    One wall of the original E Building is visible in the back of this image, looking west in Room 142, a typical laboratory space - Department of Energy, Mound Facility, Electronics Laboratory Building (E Building), One Mound Road, Miamisburg, Montgomery County, OH

  18. Solar buildings program contract summary, calendar year 1999

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    2000-06-07

    The mission of the US Department of Energy's Solar Buildings Program is to advance the development and widespread deployment of competitive solar thermal technologies for use in buildings. The long-term goal of the Program is to combine solar energy technologies with energy-efficient construction techniques and create cost-effective buildings that have a zero net need for fossil fuel energy on an annual basis. The Solar Buildings Program conducts research and development on solar technologies that can deliver heat, light, and hot water to residential and commercial buildings. By working closely with manufacturers in both the buildings and solar energy industries andmore » by supporting research at universities and national laboratories, the Solar Buildings Program brings together the diverse players developing reliable and affordable solar technologies for building applications. The National Renewable Energy Laboratory (NREL) in Golden, Colorado, and Sandia National Laboratories (SNL) in Albuquerque, New Mexico, jointly participate in the Solar Buildings Program. These two national laboratories work closely with industry researching new concepts, developing technology improvements, reducing manufacturing costs, monitoring system performance, promoting quality assurance, and identifying potential new markets. In calendar year 1999, the Solar Buildings Program focused primarily on solar hot water system research and development (R and D), US industry manufacturing assistance, and US market assistance. The Program also completed a number of other projects that were begun in earlier years. This Contract Summary describes the Program's contracted activities that were active during 1999.« less

  19. ETRMTR MECHANICAL SERVICES BUILDING, TRA653. CAMERA FACING NORTHWEST AS BUILDING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ETR-MTR MECHANICAL SERVICES BUILDING, TRA-653. CAMERA FACING NORTHWEST AS BUILDING WAS NEARLY COMPLETE. INL NEGATIVE NO. 57-3653. K. Mansfield, Photographer, 7/22/1957 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  20. BUILDING DETAILS AND SECTIONS OF MAIN PROCESSING BUILDING (CPP601). INL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    BUILDING DETAILS AND SECTIONS OF MAIN PROCESSING BUILDING (CPP-601). INL DRAWING NUMBER 200-0601-00-291-103080. ALTERNATE ID NUMBER 542-11-B-74. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID

  1. 1. BUILDING 8814, NORTH FRONT AND WEST SIDE. BUILDING 8832, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. BUILDING 8814, NORTH FRONT AND WEST SIDE. BUILDING 8832, TEST STAND 1-E, IN LEFT DISTANCE. Looking southeast. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Observation Bunker 1-D-3, Test Area 1-125, northwest end of Altair Boulevard, Boron, Kern County, CA

  2. Laboratory testing of a building envelope segment based on cellular concrete

    NASA Astrophysics Data System (ADS)

    Fořt, Jan; Pavlík, Zbyšek; Černý, Robert

    2016-07-01

    Hygrothermal performance of a building envelope based on cellular concrete blocks is studied in the paper. Simultaneously, the strain fields induced by the heat and moisture changes are monitored. The studied wall is exposed to the climatic load corresponding to the winter climatic conditions of the moderate year for Prague. The winter climatic exposure is chosen in order to simulate the critical conditions of the building structure from the point of view of material performance and temperature and humidity loading. The evaluation of hygrothermal performance of a researched wall is done on the basis of relative humidity and temperature profiles measured along the cross section of the cellular concrete blocks. Strain gauges are fixed on the wall surface in expected orientation of the blocks expansion. The obtained results show a good hygrothermal function of the analyzed cellular concrete wall and its insignificant strain.

  3. Experiment definition phase shuttle laboratory. LDRL-10.6 experiment

    NASA Technical Reports Server (NTRS)

    1976-01-01

    The work completed on the experiment definition phase of the shuttle laboratory LDRL 10.6 micrometers experiment from 27 September 1975 to 26 January 1976 was reported. This work included progress in the following areas: (1) optomechanical system: completion of detail drawings, completion of the beryllium subassembly, fabrication, checking, and weighing of approximately 95% of the detailed parts, dry film lubrication of the bearings and gears, and initiation of assembly of the gimbals; (2) optics: update of the detailed optical layout, receipt of nine mirrors and the pre-expander; (3) miscellaneous: delivery of draft material for the final report, completion of optical testing of the 10.6 micrometers receiver, and receipt, assembly, and checkout of NASA test console.

  4. Air conditioning a vaccine laboratory. [Connaught Medical Research Laboratory, Toronto, Canada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ross J.

    1976-05-01

    In 1974, the new Bacterial Vaccine Building of Connaught Medical Research Laboratories, Toronto, Canada, was opened to produce such vaccines as pertussis, typhoid, paratyphoids, and cholera and such toxoids as staphylococcus, diphtheria, and tetanus. It also produces other medicinal products. The layout of the complex and the air conditioning system necessary in all zones are described and schematically shown. (MCW)

  5. Environmental Resource Management Issues in Agronomy: A Lecture/Laboratory Course

    ERIC Educational Resources Information Center

    Munn, D. A.

    2004-01-01

    Environmental Sciences Technology T272 is a course with a laboratory addressing problems in soil and water quality and organic wastes utilization to serve students from associate degree programs in laboratory science and environmental resources management at a 2-year technical college. Goals are to build basic lab skills and understand the role…

  6. PBF Control Building (PER619) south facade. Camera faces north. Note ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PBF Control Building (PER-619) south facade. Camera faces north. Note buried tanks with bollards protecting their access hatches. Date: July 2004. INEEL negative no. HD-41-10-4 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID

  7. 10. Credit BG. Interior of control and observation room at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Credit BG. Interior of control and observation room at Control and Recording Center Building 4221/E-22. - Jet Propulsion Laboratory Edwards Facility, Control & Recording Center, Edwards Air Force Base, Boron, Kern County, CA

  8. Circular Dichroism Spectroscopy: Enhancing a Traditional Undergraduate Biochemistry Laboratory Experience

    ERIC Educational Resources Information Center

    Lewis, Russell L.; Seal, Erin L.; Lorts, Aimee R.; Stewart, Amanda L.

    2017-01-01

    The undergraduate biochemistry laboratory curriculum is designed to provide students with experience in protein isolation and purification protocols as well as various data analysis techniques, which enhance the biochemistry lecture course and give students a broad range of tools upon which to build in graduate level laboratories or once they…

  9. 10 CFR 434.504 - Use of the prototype building to determine the energy cost budget.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Alternative § 434.504 Use of the prototype building to determine the energy cost budget. 504.1Determine the... 10 Energy 3 2012-01-01 2012-01-01 false Use of the prototype building to determine the energy cost budget. 434.504 Section 434.504 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW...

  10. 10 CFR 434.504 - Use of the prototype building to determine the energy cost budget.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Alternative § 434.504 Use of the prototype building to determine the energy cost budget. 504.1Determine the... 10 Energy 3 2011-01-01 2011-01-01 false Use of the prototype building to determine the energy cost budget. 434.504 Section 434.504 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW...

  11. 10 CFR 434.504 - Use of the prototype building to determine the energy cost budget.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Alternative § 434.504 Use of the prototype building to determine the energy cost budget. 504.1 Determine the... 10 Energy 3 2014-01-01 2014-01-01 false Use of the prototype building to determine the energy cost budget. 434.504 Section 434.504 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW...

  12. 10 CFR 434.504 - Use of the prototype building to determine the energy cost budget.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Alternative § 434.504 Use of the prototype building to determine the energy cost budget. 504.1Determine the... 10 Energy 3 2013-01-01 2013-01-01 false Use of the prototype building to determine the energy cost budget. 434.504 Section 434.504 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW...

  13. 10 CFR 434.506 - Use of the reference building to determine the energy cost budget.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Alternative § 434.506 Use of the reference building to determine the energy cost budget. 506.1 Each floor... 10 Energy 3 2014-01-01 2014-01-01 false Use of the reference building to determine the energy cost budget. 434.506 Section 434.506 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW...

  14. Immediate assessment of performance of medical laboratory scientists following a 10-day malaria microscopy training programme in Nigeria.

    PubMed

    Aiyenigba, Bolatito; Ojo, Abiodun; Aisiri, Adolor; Uzim, Justus; Adeusi, Oluwole; Mwenesi, Halima

    2017-01-01

    Rapid and precise diagnosis of malaria is an essential element in effective case management and control of malaria. Malaria microscopy is used as the gold standard for malaria diagnosis, however results remain poor as positivity rate in Nigeria is consistently over 90%. The United States President's Malaria Initiative (PMI) through the Malaria Action Program for States (MAPS) supported selected states in Nigeria to build capacity for malaria microscopy. This study demonstrates the effectiveness of in-service training on malaria microscopy amongst medical laboratory scientists. The training was based on the World Health Organization (WHO) basic microscopy training manual. The 10-day training utilized a series of didactic lectures and examination of teaching slides using a CX 21 Olympus binocular microscope. All 108 medical laboratory scientists trained from 2012 to 2015 across five states in Nigeria supported by PMI were included in the study. Evaluation of the training using a pre-and post-test method was based on written test questions; reading photographic slide images of malaria parasites; and prepared slides. There was a significant improvement in the mean written pre-and post-tests scores from 37.9% (95% CI 36.2-39.6%) to 70.7% (95% CI 68.4-73.1%) ( p  < 0.001). The mean counting post-test score improved significantly from 4.2% (95% CI 2.6-5.7%) to 27.9% (95% CI 25.3-30.5%) ( p  < 0.001). Mean post-test score for computer-based picture speciation test (63.0%) and picture detection test (89.2%) were significantly higher than the mean post-test score for slide reading speciation test (38.3%) and slide reading detection test (70.7%), p  < 0.001 in both cases. Parasite detection and speciation using enhanced visual imaging was significantly improved compared with using direct microscopy. Regular in-service training and provision of functional and high resolution microscopes are needed to ensure quality routine malaria microscopy.

  15. 10 CFR 434.516 - Building exterior envelope.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Prototype and Reference Buildings, the infiltration assumptions in subsection 516.2.1 shall be prescribed.... Infiltration shall impact perimeter zones only. 516.2.1When the HVAC system is switched “on,” no infiltration shall be assumed. When the HVAC system is switched “off,” the infiltration rate for buildings with or...

  16. 10 CFR 434.516 - Building exterior envelope.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Prototype and Reference Buildings, the infiltration assumptions in subsection 516.2.1 shall be prescribed.... Infiltration shall impact perimeter zones only. 516.2.1When the HVAC system is switched “on,” no infiltration shall be assumed. When the HVAC system is switched “off,” the infiltration rate for buildings with or...

  17. 10 CFR 434.516 - Building exterior envelope.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Prototype and Reference Buildings, the infiltration assumptions in subsection 516.2.1 shall be prescribed.... Infiltration shall impact perimeter zones only. 516.2.1When the HVAC system is switched “on,” no infiltration shall be assumed. When the HVAC system is switched “off,” the infiltration rate for buildings with or...

  18. 10 CFR 434.516 - Building exterior envelope.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Prototype and Reference Buildings, the infiltration assumptions in subsection 516.2.1 shall be prescribed.... Infiltration shall impact perimeter zones only. 516.2.1When the HVAC system is switched “on,” no infiltration shall be assumed. When the HVAC system is switched “off,” the infiltration rate for buildings with or...

  19. Components of laboratory accreditation.

    PubMed

    Royal, P D

    1995-12-01

    Accreditation or certification is a recognition given to an operation or product that has been evaluated against a standard; be it regulatory or voluntary. The purpose of accreditation is to provide the consumer with a level of confidence in the quality of operation (process) and the product of an organization. Environmental Protection Agency/OCM has proposed the development of an accreditation program under National Environmental Laboratory Accreditation Program for Good Laboratory Practice (GLP) laboratories as a supplement to the current program. This proposal was the result of the Inspector General Office reports that identified weaknesses in the current operation. Several accreditation programs can be evaluated and common components identified when proposing a structure for accrediting a GLP system. An understanding of these components is useful in building that structure. Internationally accepted accreditation programs provide a template for building a U.S. GLP accreditation program. This presentation will discuss the traditional structure of accreditation as presented in the Organization of Economic Cooperative Development/GLP program, ISO-9000 Accreditation and ISO/IEC Guide 25 Standard, and the Canadian Association for Environmental Analytical Laboratories, which has a biological component. Most accreditation programs are managed by a recognized third party, either privately or with government oversight. Common components often include a formal review of required credentials to evaluate organizational structure, a site visit to evaluate the facility, and a performance evaluation to assess technical competence. Laboratory performance is measured against written standards and scored. A formal report is then sent to the laboratory indicating accreditation status. Usually, there is a scheduled reevaluation built into the program. Fee structures vary considerably and will need to be examined closely when building a GLP program.

  20. Building Blueprints: A Clear View of Technology.

    ERIC Educational Resources Information Center

    College Planning & Management, 2002

    2002-01-01

    Describes the design of the technology center at Laney College in Oakland, California, which was renovated from a welding shop. The building, which illustrates a "transparency" theme, houses the computer information systems department and serves as a multimedia teaching laboratory for the entire campus and local businesses. Includes…

  1. Laboratory evaluation of the CIP 10 personal dust sampler.

    PubMed

    Gero, A; Tomb, T

    1988-06-01

    The "capteur individuel de poussiere" CIP 10 personal dust sampler--developed by the Centre d'Etudes et Recherches de Charbonnages de France (CERCHAR) research organization--is a small, quiet, lightweight unit which samples at a flow rate of 10 L/min. It is a three-stage sampler, using two stages to remove nonrespirable dust particles and one stage to collect the respirable fraction. Airflow through the sampler is induced by the third stage, which is a rotating collector cup that contains a fine grade sponge. Laboratory tests were conducted in a dust chamber using aerosols of Arizona road dust, coal dust and silica dust. Aerosol concentrations measured with the CIP 10 were compared to those measured with the coal mine dust personal sampler unit used in the United States. The results of this study showed that aerosol concentrations measured with the CIP 10 were linearly related to those obtained with the coal mine dust personal sampler. The relationship, however, was dependent on preselector configuration and aerosol characteristics. The collection medium allows some small particles (less than 3 microns) to pass through the sampler without being collected. As much as 13% (by weight) of the aerosol that penetrated through the preseparating stages was exhausted from the sampler.

  2. 10 CFR 434.506 - Use of the reference building to determine the energy cost budget.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Alternative § 434.506 Use of the reference building to determine the energy cost budget. 506.1Each floor shall... 10 Energy 3 2011-01-01 2011-01-01 false Use of the reference building to determine the energy cost budget. 434.506 Section 434.506 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW...

  3. 10 CFR 434.506 - Use of the reference building to determine the energy cost budget.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Alternative § 434.506 Use of the reference building to determine the energy cost budget. 506.1Each floor shall... 10 Energy 3 2012-01-01 2012-01-01 false Use of the reference building to determine the energy cost budget. 434.506 Section 434.506 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW...

  4. 10 CFR 434.506 - Use of the reference building to determine the energy cost budget.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Alternative § 434.506 Use of the reference building to determine the energy cost budget. 506.1Each floor shall... 10 Energy 3 2013-01-01 2013-01-01 false Use of the reference building to determine the energy cost budget. 434.506 Section 434.506 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW...

  5. ETR HEAT EXCHANGER BUILDING, TRA644. DETAIL OF SOUTH SIDE BUILDING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ETR HEAT EXCHANGER BUILDING, TRA-644. DETAIL OF SOUTH SIDE BUILDING INSET. DEMINERALIZER WING AT RIGHT. CAMERA FACING NORTH. INL NEGATIVE NO. HD46-36-2. Mike Crane, Photographer, 4/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  6. Building and Rebuilding: The National Public Health Laboratory Systems and Services Before and After the Earthquake and Cholera Epidemic, Haiti, 2009–2015

    PubMed Central

    Jean Louis, Frantz; Buteau, Josiane; Boncy, Jacques; Anselme, Renette; Stanislas, Magalie; Nagel, Mary C.; Juin, Stanley; Charles, Macarthur; Burris, Robert; Antoine, Eva; Yang, Chunfu; Kalou, Mireille; Vertefeuille, John; Marston, Barbara J.; Lowrance, David W.; Deyde, Varough

    2017-01-01

    Abstract. Before the 2010 devastating earthquake and cholera outbreak, Haiti’s public health laboratory systems were weak and services were limited. There was no national laboratory strategic plan and only minimal coordination across the laboratory network. Laboratory capacity was further weakened by the destruction of over 25 laboratories and testing sites at the departmental and peripheral levels and the loss of life among the laboratory health-care workers. However, since 2010, tremendous progress has been made in building stronger laboratory infrastructure and training a qualified public health laboratory workforce across the country, allowing for decentralization of access to quality-assured services. Major achievements include development and implementation of a national laboratory strategic plan with a formalized and strengthened laboratory network; introduction of automation of testing to ensure better quality of results and diversify the menu of tests to effectively respond to outbreaks; expansion of molecular testing for tuberculosis, human immunodeficiency virus, malaria, diarrheal and respiratory diseases; establishment of laboratory-based surveillance of epidemic-prone diseases; and improvement of the overall quality of testing. Nonetheless, the progress and gains made remain fragile and require the full ownership and continuous investment from the Haitian government to sustain these successes and achievements. PMID:29064354

  7. Energy 101: Energy Efficient Commercial Buildings

    ScienceCinema

    None

    2018-06-06

    Learn how commercial buildings can incorporate whole-building design to save energy and money while enhancing performance and comfort. This video highlights several energy-saving features of the Research Support Facility at the Energy Department's National Renewable Energy Laboratory-a model for high-performance office building design.

  8. 49 CFR 41.110 - New DOT owned buildings and additions to buildings.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false New DOT owned buildings and additions to buildings....110 New DOT owned buildings and additions to buildings. (a) DOT Operating Administrations responsible for the design and construction of new DOT Federally owned buildings will ensure that each building is...

  9. 2. BUILDING MT76A AND MT76B FROM STREET, BUILDING MT76A IN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. BUILDING MT-76-A AND MT-76-B FROM STREET, BUILDING MT-76-A IN FOREGROUND - Fort Keogh, Livestock & Range Research Station, 3 miles west of Miles City on U.S. Highway 10, Miles City, Custer County, MT

  10. 1. West elevations of barrier (Building 4216/E17) and Monitor Building ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. West elevations of barrier (Building 4216/E-17) and Monitor Building (4203/E-4). Barrier is built of wood infilled with earth, intended to protect Monitor Building from flying debris should anything at Test Stand 'A' explode. Building 4203/E-4 is built of reinforced concrete; equipment on top of it is cooling tower for refrigeration equipment in Test Stand 'A' machinery room. Electrical utility poles are typical at the facility, and carry 4,800 volts 3-phase alternating current. - Jet Propulsion Laboratory Edwards Facility, Test Stand A, Control Center, Edwards Air Force Base, Boron, Kern County, CA

  11. Developing a customised approach for strengthening tuberculosis laboratory quality management systems toward accreditation

    PubMed Central

    Trollip, Andre; Erni, Donatelle; Kao, Kekeletso

    2017-01-01

    Background Quality-assured tuberculosis laboratory services are critical to achieve global and national goals for tuberculosis prevention and care. Implementation of a quality management system (QMS) in laboratories leads to improved quality of diagnostic tests and better patient care. The Strengthening Laboratory Management Toward Accreditation (SLMTA) programme has led to measurable improvements in the QMS of clinical laboratories. However, progress in tuberculosis laboratories has been slower, which may be attributed to the need for a structured tuberculosis-specific approach to implementing QMS. We describe the development and early implementation of the Strengthening Tuberculosis Laboratory Management Toward Accreditation (TB SLMTA) programme. Development The TB SLMTA curriculum was developed by customizing the SLMTA curriculum to include specific tools, job aids and supplementary materials specific to the tuberculosis laboratory. The TB SLMTA Harmonized Checklist was developed from the World Health Organisation Regional Office for Africa Stepwise Laboratory Quality Improvement Process Towards Accreditation checklist, and incorporated tuberculosis-specific requirements from the Global Laboratory Initiative Stepwise Process Towards Tuberculosis Laboratory Accreditation online tool. Implementation Four regional training-of-trainers workshops have been conducted since 2013. The TB SLMTA programme has been rolled out in 37 tuberculosis laboratories in 10 countries using the Workshop approach in 32 laboratories in five countries and the Facility-based approach in five tuberculosis laboratories in five countries. Conclusion Lessons learnt from early implementation of TB SLMTA suggest that a structured training and mentoring programme can build a foundation towards further quality improvement in tuberculosis laboratories. Structured mentoring, and institutionalisation of QMS into country programmes, is needed to support tuberculosis laboratories to achieve

  12. COMPRESSOR BUILDING, TRA626. ELEVATIONS. WINDOWS. WALL SECTIONS. PUMICE BLOCK BUILDING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    COMPRESSOR BUILDING, TRA-626. ELEVATIONS. WINDOWS. WALL SECTIONS. PUMICE BLOCK BUILDING HOUSED COMPRESSORS FOR AIRCRAFT NUCLEAR PROPULSION EXPERIMENTS. MTR-626-IDO-2S, 3/1952. INL INDEX NO. 531-0626-00-396-110535, REV. 2. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  13. The Effect of Body Build and BMI on Aerobic Test Performance in School Children (10-15 Years)

    PubMed Central

    Slinger, Jantine; Verstappen, Frans; Breda, Eric Van; Kuipers, Harm

    2006-01-01

    Body Mass Index (BMI) has often questionably been used to define body build. In the present study body build was defined more specifically using fat free mass index (FFMI = fat free mass normalised to the stature) and fat mass index (FMI = fat mass normalised to stature). The body build of an individual is ‘solid’ in individuals with a high FFMI for their FMI and is ‘slender’ in individuals with a low FFMI relative to their FMI. The aim of the present study was to investigate the association between aerobic test performance and body build defined as solid, average or slender in 10 to 15 year old children. Five-hundred-and-two children (53% boys) aged 10 to 15 years of age were included in the study. Aerobic test performance was estimated with an incremental cycle ergometer protocol and a shuttle run test. BMI and percentage fat (by skin folds) were determined to calculate FMI and FFMI. After adjustment for differences in age, gender and body mass the solid group achieved a significantly higher maximal power output (W) and power output relative to body mass (W/kg) during the cycle test (p < 0.05) and a higher shuttle-run score (p < 0.05) compared to the slender group. The power output relative to FFM (W/kg FFM) was comparable (p > 0.05) between different body build groups. This study showed that body build is an important determinant of the aerobic test performance. In contrast, there were no differences in aerobic test performance per kilogramme FFM over the body build groups. This suggests that the body build may be determined by genetic predisposition. Key Points Children with a solid body build perform better in aerobic exercise tests than slender children. The power output relative to fat free mass was comparable in the solid, slender and average group. Besides body composition, body build should be considered related to other performance measurements. PMID:24357967

  14. 147. ARAIII Control building (ARA607) Detail of instrument rack and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    147. ARA-III Control building (ARA-607) Detail of instrument rack and control console in control room. Aerojet-general 880-area/GCRE-607-E-4. Date: November 1958. Ineel index code no. 063-0607-10-013-102560. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  15. Laboratory twinning to build capacity for rabies diagnosis.

    PubMed

    Fooks, Anthony R; Drew, Trevor W; Tu, Changchun

    2016-03-05

    In 2009, the UK's OIE Reference Laboratory for rabies, based at the APHA in Weybridge, was awarded a project to twin with the Changchun Veterinary Research Institute in the People's Republic of China to help the institute develop the skills and methods necessary to become an OIE Reference Laboratory itself. Here, Tony Fooks, Trevor Drew and Changchun Tu describe the OIE's twinning project and the success that has since been realised in China. British Veterinary Association.

  16. Maximize Energy Efficiency in Buildings | Climate Neutral Research Campuses

    Science.gov Websites

    Buildings on a research campus, especially laboratory buildings, often represent the most cost-effective plans, campuses can evaluate the following: Energy Management Building Management New Buildings Design

  17. Room 106, A laboratory with longitudinal arrangement of benches. View ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Room 106, A laboratory with longitudinal arrangement of benches. View to west. - San Bernardino Valley College, Life Science Building, 701 South Mount Vernon Avenue, San Bernardino, San Bernardino County, CA

  18. A refuge for inorganic chemistry: Bunsen's Heidelberg laboratory.

    PubMed

    Nawa, Christine

    2014-05-01

    Immediately after its opening in 1855, Bunsen's Heidelberg laboratory became iconic as the most modern and best equipped laboratory in Europe. Although comparatively modest in size, the laboratory's progressive equipment made it a role model for new construction projects in Germany and beyond. In retrospect, it represents an intermediate stage of development between early teaching facilities, such as Liebig's laboratory in Giessen, and the new 'chemistry palaces' that came into existence with Wöhler's Göttingen laboratory of 1860. As a 'transition laboratory,' Bunsen's Heidelberg edifice is of particular historical interest. This paper explores the allocation of spaces to specific procedures and audiences within the laboratory, and the hierarchies and professional rites of passage embedded within it. On this basis, it argues that the laboratory in Heidelberg was tailored to Bunsen's needs in inorganic and physical chemistry and never aimed at a broad-scale representation of chemistry as a whole. On the contrary, it is an example of early specialisation within a chemical laboratory preceding the process of differentiation into chemical sub-disciplines. Finally, it is shown that the relatively small size of this laboratory, and the fact that after ca. 1860 no significant changes were made within the building, are inseparably connected to Bunsen's views on chemistry teaching.

  19. TA-03-0035 Press Building – D&D

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hasenack, Marvin Leroy

    The Press Building was constructed in 1954 with 15,073 ft 2 of floor space. It was built to house a 5000 ton double action Lake Erie hydraulic press and a uranium casting area. Missions included uranium activities associated with the Nuclear Weapons and Rover Rocket programs. At the end of the Rover program, the building continued to support various uranium materials science projects until the building was placed into a cold and dark status in 2013 and then was demolished in 2017. The building interior, the press, and associated systems were radiological contaminated and disposed of as low level waste.more » The demolition of this building opened up valuable real estate in the TA-3 area for the future construction of an ~11,000 Sq. Ft. Biosafety Level 2 laboratory and office building. This building will support the ongoing Bioscience Division mission at the laboratory.« less

  20. LOFT. Containment building (TAN650) detail. Camera facing east. Service building ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LOFT. Containment building (TAN-650) detail. Camera facing east. Service building corner is at left of view above personnel access. Round feature at left of dome is tank that will contain borated water. Metal stack at right of view. Date: 1973. INEEL negative no. 73-1085 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  1. 10 CFR 430.25 - Laboratory Accreditation Program.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Procedures § 430.25 Laboratory Accreditation Program. The testing for general service fluorescent lamps... Appendix R to this subpart. The testing for medium base compact fluorescent lamps shall be performed in accordance with Appendix W of this subpart. This testing shall be conducted by test laboratories accredited...

  2. 10 CFR 430.25 - Laboratory Accreditation Program.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Procedures § 430.25 Laboratory Accreditation Program. The testing for general service fluorescent lamps... Appendix R to this subpart. The testing for medium base compact fluorescent lamps shall be performed in accordance with Appendix W of this subpart. This testing shall be conducted by test laboratories accredited...

  3. NREL Helps Habitat for Humanity of Metro Denver Build Earth-Smart House

    Science.gov Websites

    Laboratory's (NREL) Exemplary Buildings team helped Habitat for Humanity of Metro Denver design a low energy April 26 from 10 a.m. to 3 p.m. Individuals interested in energy smart home design are encouraged to -tempered design, low-emissivity windows, engineered overhangs which shade the house during the summer but

  4. Conditions for building a community of practice in an advanced physics laboratory

    NASA Astrophysics Data System (ADS)

    Irving, Paul W.; Sayre, Eleanor C.

    2014-06-01

    We use the theory of communities of practice and the concept of accountable disciplinary knowledge to describe how a learning community develops in the context of an upper-division physics laboratory course. The change in accountable disciplinary knowledge motivates students' enculturation into a community of practice. The enculturation process is facilitated by four specific structural features of the course and supported by a primary instructional choice. The four structural features are "paucity of instructor time," "all in a room together," "long and difficult experiments," and "same experiments at different times." The instructional choice is the encouragement of the sharing and development of knowledge and understanding by the instructor. The combination of the instructional choice and structural features promotes the development of the learning community in which students engage in authentic practices of a physicist. This results in a classroom community that can provide students with the opportunity to have an accelerated trajectory towards being a more central participant of the community of a practice of physicists. We support our claims with video-based observations of laboratory classroom interactions and individual, semistructured interviews with students about their laboratory experiences and physics identity.

  5. School Building Organisation in Greece.

    ERIC Educational Resources Information Center

    PEB Exchange, 2001

    2001-01-01

    Discusses the past and current organizational structure of Greece's School Building Organisation, a body established to work with government agencies in the design and construction of new buildings and the provisioning of educational equipment. Future planning to incorporate culture and creativity, sports, and laboratory learning in modern school…

  6. 156. ARAIII Reactor building (ARA608) Electrical and control details of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    156. ARA-III Reactor building (ARA-608) Electrical and control details of mobile work bridge over reactor and pipiing pits. Aerojet-general 880-area/GCRE-608-E-6. Date: November 1958. Ineel index code no. 063-0608-10-013-102621. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  7. Building clinical trial capacity to develop a new treatment for multidrug-resistant tuberculosis.

    PubMed

    Tupasi, Thelma; Gupta, Rajesh; Danilovits, Manfred; Cirule, Andra; Sanchez-Garavito, Epifanio; Xiao, Heping; Cabrera-Rivero, Jose L; Vargas-Vasquez, Dante E; Gao, Mengqiu; Awad, Mohamed; Gentry, Leesa M; Geiter, Lawrence J; Wells, Charles D

    2016-02-01

    New drugs for infectious diseases often need to be evaluated in low-resource settings. While people working in such settings often provide high-quality care and perform operational research activities, they generally have less experience in conducting clinical trials designed for drug approval by stringent regulatory authorities. We carried out a capacity-building programme during a multi-centre randomized controlled trial of delamanid, a new drug for the treatment of multidrug-resistant tuberculosis. The programme included: (i) site identification and needs assessment; (ii) achieving International Conference on Harmonization - Good Clinical Practice (ICH-GCP) standards; (iii) establishing trial management; and (iv) increasing knowledge of global and local regulatory issues. Trials were conducted at 17 sites in nine countries (China, Egypt, Estonia, Japan, Latvia, Peru, the Philippines, the Republic of Korea and the United States of America). Eight of the 10 sites in low-resource settings had no experience in conducting the requisite clinical trials. Extensive capacity-building was done in all 10 sites. The programme resulted in improved local capacity in key areas such as trial design, data safety and monitoring, trial conduct and laboratory services. Clinical trials designed to generate data for regulatory approval require additional efforts beyond traditional research-capacity strengthening. Such capacity-building approaches provide an opportunity for product development partnerships to improve health systems beyond the direct conduct of the specific trial.

  8. THE GREEN DORM: A SUSTAINABLE RESIDENCE AND LIVING LABORATORY FOR STANFORD UNIVERSITY

    EPA Science Inventory

    The Lotus Living Laboratory at Stanford University is exploring sustainable building technologies and sustainable living habits through the design, construction and operation of The Green Dorm, an innovative facility containing residential, laboratory and commons space. Both ...

  9. Central African Field Epidemiology and Laboratory Training Program: building and strengthening regional workforce capacity in public health.

    PubMed

    Andze, Gervais Ondobo; Namsenmo, Abel; Illunga, Benoit Kebella; Kazambu, Ditu; Delissaint, Dieula; Kuaban, Christopher; Mbopi-Kéou, Francois-Xavier; Gabsa, Wilfred; Mulumba, Leopold; Bangamingo, Jean Pierre; Ngulefac, John; Dahlke, Melissa; Mukanga, David; Nsubuga, Peter

    2011-01-01

    The Central African Field Epidemiology and Laboratory Training Program (CAFELTP) is a 2-year public health leadership capacity building training program. It was established in October 2010 to enhance capacity for applied epidemiology and public health laboratory services in three countries: Cameroon, Central African Republic, and the Democratic Republic of Congo. The aim of the program is to develop a trained public health workforce to assure that acute public health events are detected, investigated, and responded to quickly and effectively. The program consists of 25% didactic and 75% practical training (field based activities). Although the program is still in its infancy, the residents have already responded to six outbreak investigations in the region, evaluated 18 public health surveillance systems and public health programs, and completed 18 management projects. Through these various activities, information is shared to understand similarities and differences in the region leading to new and innovative approaches in public health. The program provides opportunities for regional and international networking in field epidemiology and laboratory activities, and is particularly beneficial for countries that may not have the immediate resources to host an individual country program. Several of the trainees from the first cohort already hold leadership positions within the ministries of health and national laboratories, and will return to their assignments better equipped to face the public health challenges in the region. They bring with them knowledge, practical training, and experiences gained through the program to shape the future of the public health landscape in their countries.

  10. Central African Field Epidemiology and Laboratory Training Program: building and strengthening regional workforce capacity in public health

    PubMed Central

    Ondobo Andze, Gervais; Namsenmo, Abel; Kebella Illunga, Benoit; Kazambu, Ditu; Delissaint, Dieula; Kuaban, Christopher; Mbopi-Kéou, Francois-Xavier; Gabsa, Wilfred; Mulumba, Leopold; Pierre Bangamingo, Jean; Ngulefac, John; Dahlke, Melissa; Mukanga, David; Nsubuga, Peter

    2011-01-01

    The Central African Field Epidemiology and Laboratory Training Program (CAFELTP) is a 2-year public health leadership capacity building training program. It was established in October 2010 to enhance capacity for applied epidemiology and public health laboratory services in three countries: Cameroon, Central African Republic, and the Democratic Republic of Congo. The aim of the program is to develop a trained public health workforce to assure that acute public health events are detected, investigated, and responded to quickly and effectively. The program consists of 25% didactic and 75% practical training (field based activities). Although the program is still in its infancy, the residents have already responded to six outbreak investigations in the region, evaluated 18 public health surveillance systems and public health programs, and completed 18 management projects. Through these various activities, information is shared to understand similarities and differences in the region leading to new and innovative approaches in public health. The program provides opportunities for regional and international networking in field epidemiology and laboratory activities, and is particularly beneficial for countries that may not have the immediate resources to host an individual country program. Several of the trainees from the first cohort already hold leadership positions within the ministries of health and national laboratories, and will return to their assignments better equipped to face the public health challenges in the region. They bring with them knowledge, practical training, and experiences gained through the program to shape the future of the public health landscape in their countries. PMID:22359692

  11. 10. CONTROL ROOM INTERIOR. Looking into southwest corner. CONTROL ROOM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. CONTROL ROOM INTERIOR. Looking into southwest corner. CONTROL ROOM INTERIOR, SHOWING ESCAPE HATCH. Looking north along east wall. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Instrumentation & Control Building, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  12. Construction of a Solid State Research Facility, Building 3150. Environmental Assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-07-01

    The Department of Energy (DOE) proposes to construct a new facility to house the Materials Synthesis Group (MSG) and the Semiconductor Physics Group (SPG) of the Solid State Division, Oak Ridge National Laboratory (ORNL). The location of the proposed action is Roane County, Tennessee. MSG is involved in the study of crystal growth and the preparation and characterization of advanced materials, such as high-temperature superconductors, while SPG is involved in semiconductor physics research. All MSG and a major pardon of SPG research activities are now conducted in Building 2000, a deteriorating structure constructed in the 1940. The physical deterioration ofmore » the roof; the heating, ventilation, and air conditioning (HVAC) system; and the plumbing make this building inadequate for supporting research activities. The proposed project is needed to provide laboratory and office space for MSG and SPG and to ensure that research activities can continue without interruption due to deficiencies in the building and its associated utility systems.« less

  13. 10 CFR 434.402 - Building envelope assemblies and materials.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Design Requirements-Electric Systems and Equipment... be determined with due consideration of all major series and parallel heat flow paths through the... thermal transmittance of opaque elements of assemblies shall be determined using a series path procedure...

  14. 10 CFR 434.402 - Building envelope assemblies and materials.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Design Requirements-Electric Systems and Equipment... be determined with due consideration of all major series and parallel heat flow paths through the... thermal transmittance of opaque elements of assemblies shall be determined using a series path procedure...

  15. 10 CFR 434.402 - Building envelope assemblies and materials.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Design Requirements-Electric Systems and Equipment... be determined with due consideration of all major series and parallel heat flow paths through the... thermal transmittance of opaque elements of assemblies shall be determined using a series path procedure...

  16. 10 CFR 434.402 - Building envelope assemblies and materials.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Design Requirements-Electric Systems and Equipment... be determined with due consideration of all major series and parallel heat flow paths through the... thermal transmittance of opaque elements of assemblies shall be determined using a series path procedure...

  17. 10 CFR 434.402 - Building envelope assemblies and materials.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Design Requirements-Electric Systems and Equipment... be determined with due consideration of all major series and parallel heat flow paths through the... thermal transmittance of opaque elements of assemblies shall be determined using a series path procedure...

  18. United States Air Force Summer Research Program -- 1993 Summer Research Program Final Reports. Volume 10. Wright Laboratory

    DTIC Science & Technology

    1993-01-01

    LABORATORIES 5800 Uplander Way Culver City, CA 90230-6608 Program Director, RDL Program Manager , AFOSR Gary Moore Col. Hal Rhoades Program Manager , RDL...Laboratory: PL/RK Aerospace Engineering University of Cinc nati Vol-Page No: 8-10 Cincinnati, OH 45221-0000 Burns, Paul Field: Electrical Engineering as...Laboratory: PL/GP Electrical Engineering Boston University Vol-Page No: a- 5 Boston, MA 2215-0000 GSRP Participant Data Stauffer, Joseph Field: Management MS

  19. A Project-Based Laboratory for Learning Embedded System Design with Industry Support

    ERIC Educational Resources Information Center

    Lee, Chyi-Shyong; Su, Juing-Huei; Lin, Kuo-En; Chang, Jia-Hao; Lin, Gu-Hong

    2010-01-01

    A project-based laboratory for learning embedded system design with support from industry is presented in this paper. The aim of this laboratory is to motivate students to learn the building blocks of embedded systems and practical control algorithms by constructing a line-following robot using the quadratic interpolation technique to predict the…

  20. Sandia National Laboratories, Tonopah Test Range Fire Control Bunker (Building 09-51): Photographs and Written Historical and Descriptive Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ullrich, Rebecca A.

    The Fire Control Bunker (Building 09-51) is a contributing element to the Sandia National Laboratories (SNL) Tonopah Test Range (TTR) Historic District. The SNL TTR Historic District played a significant role in U.S. Cold War history in the areas of stockpile surveillance and non-nuclear field testing of nuclear weapons design. The district covers approximately 179,200 acres and illustrates Cold War development testing of nuclear weapons components and systems. This report includes historical information, architectural information, sources of information, project information, maps, blueprints, and photographs.

  1. Research Staff | Buildings | NREL

    Science.gov Websites

    Research Staff Research Staff Photo of Roderick Jackson Roderick Jackson Laboratory Program Manager -related research at NREL. He works closely with senior laboratory management to set the strategic agenda for NREL's buildings portfolio, including all research, development, and market implementation

  2. Comparison of Building Loads Analysis and System Thermodynamics (BLAST) Computer Program Simulations and Measured Energy Use for Army Buildings.

    DTIC Science & Technology

    1980-05-01

    engineering ,ZteNo D R RPTE16 research w 9 laboratory COMPARISON OF BUILDING LOADS ANALYSIS AND SYSTEM THERMODYNAMICS (BLAST) AD 0 5 5,0 3COMPUTER PROGRAM...Building Loads Analysis and System Thermodynamics (BLAST) computer program. A dental clinic and a battalion headquarters and classroom building were...Building and HVAC System Data Computer Simulation Comparison of Actual and Simulated Results ANALYSIS AND FINDINGS

  3. Field and Wind Tunnel Testing on Natural Ventilation Cooling Effects on Three Navy Buildings.

    DTIC Science & Technology

    1984-12-01

    ORGANIZATION NAME AND ADDRESS 10 PROGRAM ELEMENT. PROJECT, TASK NAVAL CIVIL ENGINEERING LABORATORY AE OEUI UBR Port Hueneme, CA 93043S02-13A 7Y/ 11I...base of pressure difference coefficients for a variety of buildings with spe- cific architechtural features. Values from this data base can be used to

  4. Environmental Sustainability and Mold Hygiene in Buildings

    PubMed Central

    Ng, Tsz Wai; Lai, Ka Man

    2018-01-01

    Environmental sustainability is one of the key issues in building management. In Hong Kong, one of the initiatives is to reduce the operation hours of air-conditioning in buildings to cut down energy consumption. In this study, we reported a mold contamination case in a newly refurbished laboratory, in which the air-conditioner was switched from 24- to 18-h mode after refurbishment. In order to prevent mold recurrence, the air-conditioner was switched back to 24-h mode in the laboratory. During the mold investigation, visible mold patches in the laboratory were searched and then cultured, counted and identified. Building and environmental conditions were recorded, and used to deduce different causes of mold contamination. Eight contaminated sites including a wall, a bench, some metal and plastic surfaces and seven types of molds including two Cladosporium spp., two Aspergillus spp., one Rhizopus sp., one Trichoderma sp., and one Tritirachium sp. were identified. Cladosporium spp. were the most abundant and frequently found molds in the laboratory. The contaminated areas could have one to five different species on them. Based on the mold and environmental conditions, several scenarios causing the mold contamination were deduced, and different mold control measures were discussed to compare them with the current solution of using 24-h air-conditioning to control mold growth. This study highlights the importance of mold hygiene in sustainable building management. PMID:29617339

  5. Environmental Sustainability and Mold Hygiene in Buildings.

    PubMed

    Wu, Haoxiang; Ng, Tsz Wai; Wong, Jonathan Wc; Lai, Ka Man

    2018-04-04

    Environmental sustainability is one of the key issues in building management. In Hong Kong, one of the initiatives is to reduce the operation hours of air-conditioning in buildings to cut down energy consumption. In this study, we reported a mold contamination case in a newly refurbished laboratory, in which the air-conditioner was switched from 24- to 18-h mode after refurbishment. In order to prevent mold recurrence, the air-conditioner was switched back to 24-h mode in the laboratory. During the mold investigation, visible mold patches in the laboratory were searched and then cultured, counted and identified. Building and environmental conditions were recorded, and used to deduce different causes of mold contamination. Eight contaminated sites including a wall, a bench, some metal and plastic surfaces and seven types of molds including two Cladosporium spp., two Aspergillus spp., one Rhizopus sp., one Trichoderma sp., and one Tritirachium sp. were identified. Cladosporium spp. were the most abundant and frequently found molds in the laboratory. The contaminated areas could have one to five different species on them. Based on the mold and environmental conditions, several scenarios causing the mold contamination were deduced, and different mold control measures were discussed to compare them with the current solution of using 24-h air-conditioning to control mold growth. This study highlights the importance of mold hygiene in sustainable building management.

  6. MATERIALS TESTING REACTOR (MTR) BUILDING, TRA603. CONTEXTUAL VIEW OF MTR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    MATERIALS TESTING REACTOR (MTR) BUILDING, TRA-603. CONTEXTUAL VIEW OF MTR BUILDING SHOWING NORTH SIDES OF THE HIGH-BAY REACTOR BUILDING, ITS SECOND/THIRD FLOOR BALCONY LEVEL, AND THE ATTACHED ONE-STORY OFFICE/LABORATORY BUILDING, TRA-604. CAMERA FACING SOUTHEAST. VERTICAL CONCRETE-SHROUDED BEAMS SUPPORT PRECAST CONCRETE PANELS. CONCRETE PROJECTION FORMED AS A BUNKER AT LEFT OF VIEW IS TRA-657, PLUG STORAGE BUILDING. INL NEGATIVE NO. HD46-42-1. Mike Crane, Photographer, 4/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  7. A System for Measuring the Sway of the Vehicle Assembly Building

    NASA Technical Reports Server (NTRS)

    Youngquist, Robert; Starr, Stanley; Lane, John; Simmons, Stephen; Ihlefeld, Curtis

    2013-01-01

    A system was developed to measure the sway of the Vehicle Assembly Building (VAB) at Kennedy Space Center. This system was installed in the VAB and gathered more than one total year of data. The building movement was correlated with measurements provided by three wind towers in order to determine the maximum deflection of the building during high-wind events. The VAB owners were in the process of obtaining new platforms for use in assembling very tall rockets when analysis of the VAB showed that a high wind could move the building sufficiently that an upper platform might impact a rocket. The problem arises because safety requires a relatively small gap between the platform and the rocket, while a large enough gap is needed to ensure that stacking tolerances prevent contact between the rocket and the platform. This only leaves an inch or two (approximately 2 to 5 cm) of total clearance, so when the analysis showed that more than a couple of inches of motion could occur in a high wind, there was a potential for damaging the rocket. The KSC Applied Physics Laboratory was asked to install a system in the VAB that could measure the motion of the building in high winds to determine the actual building sway. The motion of the VAB roof under wind load was measured optically, and under analysis, it was determined that a relatively large-aperture optical system would be required to reduce diffraction effects to less than a small fraction of an inch (approximately mm) at a distance of 500 ft (˜150 m). A 10-in. (approximately 250 mm) telescope was placed on the floor of the building, looking at the ceiling. On the ceiling, a flat plate with three white LEDs was mounted in an "L" shape, such that the telescope was essentially looking at three stars. Software was written to track the motion of these three points using an image processing system. This provided a better than 1/10-in. (approximately 2.5-mm) 2D measurement faster than once a second. Data was downloaded once a

  8. NREL Buildings Research Video

    ScienceCinema

    None

    2017-12-09

    Through research, the National Renewable Energy Laboratory (NREL) has developed many strategies and design techniques to ensure both commercial and residential buildings use as little energy as possible and also work well with the surroundings. Here you will find a video that introduces the work of NREL Buildings Research, highlights some of the facilities on the NREL campus, and demonstrates these efficient building strategies. Watch this video to see design highlights of the Science and Technology Facility on the NREL campus—the first Federal building to be LEED® Platinum certified. Additionally, the video demonstrates the energy-saving features of NRELs Thermal Test Facility.

  9. Aeroacoustic Study of a 26%-Scale Semispan Model of a Boeing 777 Wing in the NASA Ames 40- by 80-Foot Wind Tunnel

    NASA Technical Reports Server (NTRS)

    Horne, W. Clifton; Burnside, Nathan J.; Soderman, Paul T.; Jaeger, Stephen M.; Reinero, Bryan R.; James, Kevin D.; Arledge, Thomas K.

    2004-01-01

    An acoustic and aerodynamic study was made of a 26%-scale unpowered Boeing 777 aircraft semispan model in the NASA Ames 40- by 80-Foot Wind Tunnel for the purpose of identifying and attenuating airframe noise sources. Simulated approach and landing configurations were evaluated at Mach numbers between 0.12 and 0.24. Cruise configurations were evaluated at Mach numbers between 0.24 and 0.33. The research team used two Ames phased-microphone arrays, a large fixed array and a small traversing array, mounted under the wing to locate and compare various noise sources in the wing high-lift system and landing gear. Numerous model modifications and noise alleviation devices were evaluated. Simultaneous with acoustic measurements, aerodynamic forces were recorded to document aircraft conditions and any performance changes caused by the geometric modifications. Numerous airframe noise sources were identified that might be important factors in the approach and landing noise of the full-scale aircraft. Several noise-control devices were applied to each noise source. The devices were chosen to manipulate and control, if possible, the flow around the various tips and through the various gaps of the high-lift system so as to minimize the noise generation. Fences, fairings, tip extensions, cove fillers, vortex generators, hole coverings, and boundary-layer trips were tested. In many cases, the noise-control devices eliminated noise from some sources at specific frequencies. When scaled to full-scale third-octave bands, typical noise reductions ranged from 1 to 10 dB without significant aerodynamic performance loss.

  10. 137. ARAII Building ARA602 floor plan as it appeared in ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    137. ARA-II Building ARA-602 floor plan as it appeared in 1980 when electrical modifications were being made. Shows partial layout of floor plan. EG&G Idaho, Inc. 1570-ARA-II-602-E-3. Date: April 1980. Ineel index code no. 070--0602-10-220-159761. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  11. Removal design report for the 108-F Biological Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1997-09-01

    Most of the 100-F facilities were deactivated with the reactor and have since been demolished. Of the dozen or so reactor-related structures, only the 105-F Reactor Building and the 108-F Biology Laboratory remain standing today. The 108-F Biology Laboratory was intended to be used as a facility for the mixing and addition of chemicals used in the treatment of the reactor cooling water. Shortly after F Reactor began operation, it was determined that the facility was not needed for this purpose. In 1949, the building was converted for use as a biological laboratory. In 1962, the lab was expanded bymore » adding a three-story annex to the original four-story structure. The resulting lab had a floor area of approximately 2,883 m{sup 2} (main building and annex) that operated until 1973. The building contained 47 laboratories, a number of small offices, a conference room, administrative section, lunch and locker rooms, and a heavily shielded, high-energy exposure cell. The purpose of this removal design report is to establish the methods of decontamination and decommissioning and the supporting functions associated with facility removal and disposal.« less

  12. 10. Photocopy of photograph, U.S. Army, ca. 1943 (original print ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Photocopy of photograph, U.S. Army, ca. 1943 (original print located at Rocky Mountain Arsenal, Commerce City, Colorado). R.M.A. - 313 - CONTROL LAB ROOM 109. - Rocky Mountain Arsenal, Laboratory Building, 510 feet South of December Seventh Avenue; 175 feet East of D Street, Commerce City, Adams County, CO

  13. 10 CFR 26.155 - Laboratory personnel.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... and graduate education in biology, chemistry, and pharmacology or toxicology; or (iii) Training and... additional training and laboratory/research experience in biology, chemistry, and pharmacology or toxicology...

  14. 10 CFR 26.155 - Laboratory personnel.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... and graduate education in biology, chemistry, and pharmacology or toxicology; or (iii) Training and... additional training and laboratory/research experience in biology, chemistry, and pharmacology or toxicology...

  15. 10 CFR 26.155 - Laboratory personnel.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... and graduate education in biology, chemistry, and pharmacology or toxicology; or (iii) Training and... additional training and laboratory/research experience in biology, chemistry, and pharmacology or toxicology...

  16. 10 CFR 26.155 - Laboratory personnel.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... and graduate education in biology, chemistry, and pharmacology or toxicology; or (iii) Training and... additional training and laboratory/research experience in biology, chemistry, and pharmacology or toxicology...

  17. PBF Cooling Tower (PER720), and Auxiliary Building (PER624). Camera faces ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PBF Cooling Tower (PER-720), and Auxiliary Building (PER-624). Camera faces north to show south facades. Oblong vertical structure at left of center is weather shield for stairway. Date: August 2003. INEEL negative no. HD-35-10-4 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID

  18. Elevated Building Lift Systems on Permanent Snowfields: A Report on the Elevated Building Lift Systems in Polar Environments Workshop

    DTIC Science & Technology

    2014-09-18

    the power plant and mechanical systems, the “Noisy” building, and the “Quiet” building...6040 m² Garage (buried): 835 m² Cargo Arch (buried) : 1640 m² Power Plant (buried) : 600 m² Fuel Arch (buried) : 1325 m² Habitat: 1640 m...Laboratory: 210 m² Garage: 2623 m² Total: 4473 m² Main Bldgs.: 1612 m² Power plant : 188 m² Population Summer: 52 Winter: 16 Summer (3 mo.): 150

  19. Modeling Radial Holoblastic Cleavage: A Laboratory Activity for Developmental Biology.

    ERIC Educational Resources Information Center

    Ellis, Linda K.

    2000-01-01

    Introduces a laboratory activity designed for an undergraduate developmental biology course. Uses Play-Doh (plastic modeling clay) to build a multicellular embryo in order to provide a 3-D demonstration of cleavage. Includes notes for the instructor and student directions. (YDS)

  20. iVirtualWorld: A Domain-Oriented End-User Development Environment for Building 3D Virtual Chemistry Experiments

    ERIC Educational Resources Information Center

    Zhong, Ying

    2013-01-01

    Virtual worlds are well-suited for building virtual laboratories for educational purposes to complement hands-on physical laboratories. However, educators may face technical challenges because developing virtual worlds requires skills in programming and 3D design. Current virtual world building tools are developed for users who have programming…

  1. 1. Exterior view of Components Test Laboratory (T27), looking southeast ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Exterior view of Components Test Laboratory (T-27), looking southeast from hill north of structure. The building wing in the right foreground houses Test Cell 8 (oxidizer) and the oxidizer storage pit or vault. Test Cell 10 is located in the center background, Test Cell 9 is at the far left, and the equipment room is in the immediate left foreground. The control room is in the center of the structure and abuts the aforementioned test cell and equipment room wings. This structure served as a facility for testing, handling, and storage of Titan II's hydrazine- and nitrogen teteroxide-based propellant system components for compatability determinations. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  2. Room 202, a small laboratory between the west stairs on ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Room 202, a small laboratory between the west stairs on the left, and faculty offices to the right. View to north. - San Bernardino Valley College, Life Science Building, 701 South Mount Vernon Avenue, San Bernardino, San Bernardino County, CA

  3. A&M. Hot liquid waste treatment building (TAN616). Contextual view, facing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A&M. Hot liquid waste treatment building (TAN-616). Contextual view, facing south. Wall of hot shop (TAN-607) with high bay at left of view. Lower-roofed building at left edge of view is TAN- 633, hot cell annex. Complex at center of view is TAN-616. Tall metal building with gable roof is TAN-615. Photographer: Ron Paarmann. Date: September 22, 1997. INEEL negative no. HD-20-2-2 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  4. A research update for southeast poultry research laboratory

    USDA-ARS?s Scientific Manuscript database

    The Southeast Poultry Research Laboratory continues with their modernization plan. The 35% architectural drawings have been completed and the project is currently out for bid for the completion of the design and building of the new facility. Research activities in the Exotic and Emerging Avian Vir...

  5. North side, looking southeast. Leading to building 513. Fitzsimons ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    North side, looking southeast. Leading to building 513. - Fitzsimons General Hospital, Dental Laboratory, North of Building No. 511, West of corridor connecting Buildings 511 & 515, Aurora, Adams County, CO

  6. PROCESS WATER BUILDING, TRA605. INSIDE A FLASH EVAPORATOR. INL NEGATIVE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PROCESS WATER BUILDING, TRA-605. INSIDE A FLASH EVAPORATOR. INL NEGATIVE NO. 3323. Unknown Photographer, 9/12/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  7. Phlebotomy, a bridge between laboratory and patient.

    PubMed

    Ialongo, Cristiano; Bernardini, Sergio

    2016-01-01

    The evidence-based paradigm has changed and evolved medical practice. Phlebotomy, which dates back to the age of ancient Greece, has gained experience through the evolution of medicine becoming a fundamental diagnostic tool. Nowadays it connects the patient with the clinical laboratory dimension building up a bridge. However, more often there is a gap between laboratory and phlebotomist that causes misunderstandings and burdens on patient safety. Therefore, the scope of this review is delivering a view of modern phlebotomy to "bridge" patient and laboratory. In this regard the paper describes devices, tools and procedures in the light of the most recent scientific findings, also discussing their impact on both quality of blood testing and patient safety. It also addresses the issues concerning medical aspect of venipuncture, like the practical approach to the superficial veins anatomy, as well as the management of the patient's compliance with the blood draw. Thereby, the clinical, technical and practical issues are treated with the same relevance throughout the entire paper.

  8. Field and laboratory comparison of PM10 instruments in high winds

    NASA Astrophysics Data System (ADS)

    Sharratt, Brenton; Pi, Huawei

    2018-06-01

    Instruments capable of measuring PM10 (particulate matter ≤10 μm in aerodynamic diameter) concentrations may vary in performance as a result of different technologies utilized in measuring PM10. Therefore, the performance of five instruments capable of measuring PM10 concentrations above eroding soil surfaces was tested during high wind events at field sites in the Columbia Plateau and inside a wind tunnel. Comparisons among the Big Spring Number Eight (BSNE) sampler, DustTrak monitor, E-sampler, High-Volume sampler, and Tapered Element Oscillating Microbalance (TEOM) monitor were made at field sites during nine wind erosion events and inside a wind tunnel at two wind speeds (7 and 12 m s-1) and two ambient PM10 concentrations (2 and 50 mg m-3). PM10 concentrations were similar for the High-Volume sampler and TEOM monitor as well as for the BSNE samplers and DustTrak monitors but higher for the High-Volume sampler and TEOM monitor than the E-sampler during field erosion events. Based upon wind tunnel experiments, the TEOM monitor measured the highest PM10 concentration while the DustTrak monitor typically measured the lowest PM10 concentration as compared with other instruments. In addition, PM10 concentration appeared to lower for all instruments at a wind speed of 12 as compared with 7 m s-1 inside the wind tunnel. Differences in the performance of instruments in measuring PM10 concentration poses risks in comparing PM10 concentration among different instrument types or using multiple instrument types to jointly measure concentrations in the field or laboratory or even the same instrument type subject to different wind speeds.

  9. 116. ARAI Details of hot cell section of building ARA626. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    116. ARA-I Details of hot cell section of building ARA-626. Shows manipulator openings in operating face of hot cell, start/stop buttons, and other details. Norman Engineering Company 961/area/SF-626-E-6. Date: January 1959. Ineel index code no. 068-0626-10-613-102731. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  10. A Research Update for Southeast Poultry Research Laboratory

    USDA-ARS?s Scientific Manuscript database

    The Southeast Poultry Research Laboratory continues with their modernization plan. The 35% architectural drawings have been completed and the project is currently out for bid for the completion of the design and building of the new facility. Research activities include responding to the H7N9 highl...

  11. An Online Virtual Laboratory of Electricity

    ERIC Educational Resources Information Center

    Gómez Tejedor, J. A.; Moltó Martínez, G.; Barros Vidaurre, C.

    2008-01-01

    In this article, we describe a Java-based virtual laboratory, accessible via the Internet by means of a Web browser. This remote laboratory enables the students to build both direct and alternating current circuits. The program includes a graphical user interface which resembles the connection board, and also the electrical components and tools…

  12. Protein Laboratories in Single Location | Poster

    Cancer.gov

    By Andrew Stephen, Timothy Veenstra, and Gordon Whiteley, Guest Writers, and Ken Michaels, Staff Writer The Laboratory of Proteomics and Analytical Technologies (LPAT), Antibody Characterization Laboratory (ACL), and Protein Chemistry Laboratory (PCL), previously located on different floors or in different buildings, are now together on the first floor of C wing in the ATRF.

  13. Building Toxic Metal Characterization and Decontamination Report: Area 6, Building 914

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NSTec Industrial Hygiene

    2011-08-15

    The purpose of this report is to outline the toxic metal characterization and decontamination efforts in Area 6, Building 914. This includes the initial building inspection, the hotspot sampling, results/findings, building cleanup, and the verification sampling. Building 914 is a steel light frame building that was constructed in 1992. It is about 16,454 square feet, and five employees are assigned to this building. According to the building's floor plan blueprints, it could be inferred that this building was once a Wiremen/Lineman shop. In 2002-2004, the National Nuclear Security Administration Nevada Site Office embarked on a broad characterization of beryllium (Be)more » surface concentrations throughout the North Las Vegas Facility, the Nevada National Security Site (NNSS), and ancillary facilities like the Special Technologies Laboratory, Remote Sensing Laboratory, etc. Building 914 was part of this characterization. The results of the 2002 study illustrated that the metal housekeeping limits were within acceptable limits and from a Be standpoint, the building was determined to be fit for occupancy. On March 2, 2011, based on a request from Building 914 users, National Security Technologies, LLC (NSTec) Industrial Hygiene (IH) collected bulk samples from the southwest corner of Building 914 at heights above 6 feet where black dust had been noticed on this particular wall. IH conducted surface swipe sampling of the area and analyzed the samples for toxic metals, namely, beryllium (Be), cadmium (Cd), chromium (Cr), lead (Pb), and manganese (Mn). The sample results indicated values two to four times above the housekeeping threshold for Be, Cd, Cr, Pb, and Mn. Subsequently, the facility was closed and posted; the necessary personnel were notified; and controls were instituted for ingress and egress of the building. On March 17, 2011, IH performed an extensive sampling event involving the entire warehouse in accordance with NSTec Organization Procedure OP-P250

  14. The Vanderbilt University nanoscale science and engineering fabrication laboratory

    NASA Astrophysics Data System (ADS)

    Hmelo, Anthony B.; Belbusti, Edward F.; Smith, Mark L.; Brice, Sean J.; Wheaton, Robert F.

    2005-08-01

    Vanderbilt University has realized the design and construction of a 1635 sq. ft. Class 10,000 cleanroom facility to support the wide-ranging research mission associated with the Vanderbilt Institute for Nanoscale Science and Engineering (VINSE). By design we have brought together disparate technologies and researchers formerly dispersed across the campus to work together in a small contiguous space intended to foster interaction and synergy of nano-technologies not often found in close proximity. The space hosts a variety of tools for lithographic patterning of substrates, the deposition of thin films, the synthesis of diamond nanostructures and carbon nanotubes, and a variety of reactive ion etchers for the fabrication of nanostructures on silicon substrates. In addition, a separate 911 sq. ft. chemistry laboratory supports nanocrystal synthesis and the investigation of biomolecular films. The design criteria required an integrated space that would support the scientific agenda of the laboratory while satisfying all applicable code and safety concerns. This project required the renovation of pre-existing laboratory space with minimal disruption to ongoing activities in a mixed-use building, while meeting the requirements of the 2000 edition of the International Building Code for the variety of potentially hazardous processes that have been programmed for the space. In this paper we describe how architectural and engineering challenges were met in the areas of mitigating floor vibration issues, shielding our facility against EMI emanations, design of the contamination control facility itself, chemical storage and handling, toxic gas use and management, as well as mechanical, electrical, plumbing, lab security, fire and laboratory safety issues.

  15. RLE (Research Laboratory of Electronics) Progress Report Number 129.

    DTIC Science & Technology

    1987-01-01

    8217," ’,/’.’t MICROCOP ,"Y RESOLUTION TEST C-’HA"-/’%’.’."."% "-’- -" "."o -- - -" " OI FILE COPYAJ MASSACHUSETTS INSTITUTE OF EHOGYD The RESEARCH LABORATORY of...Intercalation Compound Structures and Transitions .................................. 59 10.0 Semiconductor Surface Studies...understanding of the HEMT, which is the basic block in building surface superlattices on III-V compound materials, our device structure has been simu

  16. Field Test Data for Detecting Vibrations of a Building Using High-Speed Video Cameras

    DTIC Science & Technology

    2017-10-01

    ARL-TR-8185 ● OCT 2017 US Army Research Laboratory Field Test Data for Detecting Vibrations of a Building Using High -Speed Video...Field Test Data for Detecting Vibrations of a Building Using High -Speed Video Cameras by Caitlin P Conn and Geoffrey H Goldman Sensors and...June 2016 – October 2017 4. TITLE AND SUBTITLE Field Test Data for Detecting Vibrations of a Building Using High -Speed Video Cameras 5a. CONTRACT

  17. Pre Incident Planning For The Los Alamos National Laboratory

    DTIC Science & Technology

    2017-12-01

    laboratory was asked to design and build the world’s first atomic bomb . The Los Alamos Fire Department (LAFD) provides emergency response services to...Project: the newly established laboratory was asked to design and build the world’s first atomic bomb . The Los Alamos Fire Department (LAFD) provides...lower priority despite its importance to the responders’ scene safety.20 In a Carolina Fire Rescue EMS Journal article, retired New York City

  18. 1. BUILDING 8698, TEST STAND 13, WEST ELEVATION. NOTE TUNNEL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. BUILDING 8698, TEST STAND 1-3, WEST ELEVATION. NOTE TUNNEL BETWEEN BLDG. 8668 AND TEST STAND 1-3. TEST AREA 1-120 IN THE MIDDLE DISTANCE, AND TEST AREA 1-125 ON THE HORIZON. Looking northeast from the roof of Building 8668, Instrumentation and Control Center. Note: Photograph CA-236-F-2 is an 8" x 10" enlargement from a 4" x 5" negative. This view is a photocopy of a recent resin coated print made from a print held at the Main Base History Office, Edwards Air Force Base, California. Photographer unknown. Date and file number unknown. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-3, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  19. An investigation of the ionospheric F region near the EIA crest in India using OI 777.4 and 630.0 nm nightglow observations

    NASA Astrophysics Data System (ADS)

    Parihar, Navin; Radicella, Sandro Maria; Nava, Bruno; Migoya-Orue, Yenca Olivia; Tiwari, Prabhakar; Singh, Rajesh

    2018-05-01

    Simultaneous observations of OI 777.4 and OI 630.0 nm nightglow emissions were carried at a low-latitude station, Allahabad (25.5° N, 81.9° E; geomag. lat. ˜ 16.30° N), located near the crest of the Appleton anomaly in India during September-December 2009. This report attempts to study the F region of ionosphere using airglow-derived parameters. Using an empirical approach put forward by Makela et al. (2001), firstly, we propose a novel technique to calibrate OI 777.4 and 630.0 nm emission intensities using Constellation Observing System for Meteorology, Ionosphere, and Climate/Formosa Satellite Mission 3 (COSMIC/FORMOSAT-3) electron density profiles. Next, the electron density maximum (Nm) and its height (hmF2) of the F layer have been derived from the information of two calibrated intensities. Nocturnal variation of Nm showed the signatures of the retreat of the equatorial ionization anomaly (EIA) and the midnight temperature maximum (MTM) phenomenon that are usually observed in the equatorial and low-latitude ionosphere. Signatures of gravity waves with time periods in the range of 0.7-3.0 h were also seen in Nm and hmF2 variations. Sample Nm and hmF2 maps have also been generated to show the usefulness of this technique in studying ionospheric processes.

  20. Building local human resources to implement SLMTA with limited donor funding: The Ghana experience.

    PubMed

    Nkrumah, Bernard; van der Puije, Beatrice; Bekoe, Veronica; Adukpo, Rowland; Kotey, Nii A; Yao, Katy; Fonjungo, Peter N; Luman, Elizabeth T; Duh, Samuel; Njukeng, Patrick A; Addo, Nii A; Khan, Fazle N; Woodfill, Celia J I

    2014-11-03

    In 2009, Ghana adopted the Strengthening Laboratory Management Toward Accreditation (SLMTA) programme in order to improve laboratory quality. The programme was implemented successfully with limited donor funding and local human resources. To demonstrate how Ghana, which received very limited PEPFAR funding, was able to achieve marked quality improvement using local human resources. Local partners led the SLMTA implementation and local mentors were embedded in each laboratory. An in-country training-of-trainers workshop was conducted in order to increase the pool of local SLMTA implementers. Three laboratory cohorts were enrolled in SLMTA in 2011, 2012 and 2013. Participants from each cohort attended in a series of three workshops interspersed with improvement projects and mentorship. Supplemental training on internal audit was provided. Baseline, exit and follow-up audits were conducted using the Stepwise Laboratory Quality Improvement Process Towards Accreditation (SLIPTA) checklist. In November 2013, four laboratories underwent official SLIPTA audits by the African Society for Laboratory Medicine (ASLM). The local SLMTA team successfully implemented three cohorts of SLMTA in 15 laboratories. Seven out of the nine laboratories that underwent follow-up audits have reached at least one star. Three out of the four laboratories that underwent official ASLM audits were awarded four stars. Patient satisfaction increased from 25% to 70% and sample rejection rates decreased from 32% to 10%. On average, $40 000 was spent per laboratory to cover mentors' salaries, SLMTA training and improvement project support. Building in-country capacity through local partners is a sustainable model for improving service quality in resource-constrained countries such as Ghana. Such models promote country ownership, capacity building and the use of local human resources for the expansion of SLMTA.

  1. INL High Performance Building Strategy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jennifer D. Morton

    High performance buildings, also known as sustainable buildings and green buildings, are resource efficient structures that minimize the impact on the environment by using less energy and water, reduce solid waste and pollutants, and limit the depletion of natural resources while also providing a thermally and visually comfortable working environment that increases productivity for building occupants. As Idaho National Laboratory (INL) becomes the nation’s premier nuclear energy research laboratory, the physical infrastructure will be established to help accomplish this mission. This infrastructure, particularly the buildings, should incorporate high performance sustainable design features in order to be environmentally responsible and reflectmore » an image of progressiveness and innovation to the public and prospective employees. Additionally, INL is a large consumer of energy that contributes to both carbon emissions and resource inefficiency. In the current climate of rising energy prices and political pressure for carbon reduction, this guide will help new construction project teams to design facilities that are sustainable and reduce energy costs, thereby reducing carbon emissions. With these concerns in mind, the recommendations described in the INL High Performance Building Strategy (previously called the INL Green Building Strategy) are intended to form the INL foundation for high performance building standards. This revised strategy incorporates the latest federal and DOE orders (Executive Order [EO] 13514, “Federal Leadership in Environmental, Energy, and Economic Performance” [2009], EO 13423, “Strengthening Federal Environmental, Energy, and Transportation Management” [2007], and DOE Order 430.2B, “Departmental Energy, Renewable Energy, and Transportation Management” [2008]), the latest guidelines, trends, and observations in high performance building construction, and the latest changes to the Leadership in Energy and Environmental

  2. A&M. Hot liquid waste building (TAN616). Interior of evaporator control ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A&M. Hot liquid waste building (TAN-616). Interior of evaporator control room. Date: 1962. INEEL negative no. 62-6824 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  3. Laboratory safety handbook

    USGS Publications Warehouse

    Skinner, E.L.; Watterson, C.A.; Chemerys, J.C.

    1983-01-01

    Safety, defined as 'freedom from danger, risk, or injury,' is difficult to achieve in a laboratory environment. Inherent dangers, associated with water analysis and research laboratories where hazardous samples, materials, and equipment are used, must be minimized to protect workers, buildings, and equipment. Managers, supervisors, analysts, and laboratory support personnel each have specific responsibilities to reduce hazards by maintaining a safe work environment. General rules of conduct and safety practices that involve personal protection, laboratory practices, chemical handling, compressed gases handling, use of equipment, and overall security must be practiced by everyone at all levels. Routine and extensive inspections of all laboratories must be made regularly by qualified people. Personnel should be trained thoroughly and repetitively. Special hazards that may involve exposure to carcinogens, cryogenics, or radiation must be given special attention, and specific rules and operational procedures must be established to deal with them. Safety data, reference materials, and texts must be kept available if prudent safety is to be practiced and accidents prevented or minimized.

  4. Contamination source review for Building E3163, Edgewood Area, Aberdeen Proving Ground, Maryland

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Draugelis, A.K.; Muir-Ploense, K.L.; Glennon, M.A.

    1995-09-01

    This report was prepared by Argonne National Laboratory (ANL) to document the results of a contamination source review for Building E3163 at the Aberdeen Proving Ground (APG) in Maryland. This report may be used to assist the US Army in planning for the future use or disposition of this building. The review included a historical records search, physical inspection, photographic documentation, and geophysical investigation. The field investigations were performed by ANL during 1994 and 1995. Building E3163 (APG designation) is part of the Medical Research Laboratories E3160 Complex. This research laboratory complex is located west of Kings Creek, east ofmore » the airfield and Ricketts Point Road, and south of Kings Creek Road in the Edgewood Area of APG. The original structures in the E3160 Complex were constructed during World War II. The complex was originally used as a medical research laboratory. Much of the research involved wound assessment. Building E3163, constructed in 1946, was used for toxicological studies on animals until 1965. All agent testing was done using laboratory-scale quantities of agents. All operational data were destroyed; total quantities and types of agents used during the testing are unknown. No experimentation has been conducted in the building since 1965. However, the building was used as overflow office space until the late 1980s. Since that time, the building has been unoccupied.« less

  5. This photograph, taken from the main roof of E Building, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    This photograph, taken from the main roof of E Building, looking north, shows two metal penthouses at right, a similar brick structure and some of the vents and other mechanical devices of the building - Department of Energy, Mound Facility, Electronics Laboratory Building (E Building), One Mound Road, Miamisburg, Montgomery County, OH

  6. Laboratory Study of Polychlorinated Biphenyl Contamination and Mitigation in Buildings -- Part 4. Evaluation of the Activated Metal Treatment System (AMTS) for On-site Destruction of PCBs

    EPA Science Inventory

    This is the fourth, also the last, report of the report series entitled “Laboratory Study of Polychlorinated Biphenyl (PCB) Contamination and Mitigation in Buildings.” This report evaluates the performance of an on-site PCB destruction method, known as the AMTS method...

  7. A&M. Hot liquid waste building (TAN616) under construction. Camera facing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A&M. Hot liquid waste building (TAN-616) under construction. Camera facing northeast. Date: November 25, 1953. INEEL negative no. 9232 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  8. Radon Mitigation Approach in a Laboratory Measurement Room

    PubMed Central

    Blanco-Rodríguez, Patricia; Fernández-Serantes, Luis Alfonso; Otero-Pazos, Alberto; Calvo-Rolle, José Luis; de Cos Juez, Francisco Javier

    2017-01-01

    Radon gas is the second leading cause of lung cancer, causing thousands of deaths annually. It can be a problem for people or animals in houses, workplaces, schools or any building. Therefore, its mitigation has become essential to avoid health problems and to prevent radon from interfering in radioactive measurements. This study describes the implementation of radon mitigation systems at a radioactivity laboratory in order to reduce interferences in the different works carried out. A large set of radon concentration samples is obtained from measurements at the laboratory. While several mitigation methods were taken into account, the final applied solution is explained in detail, obtaining thus very good results by reducing the radon concentration by 76%. PMID:28492468

  9. Radon Mitigation Approach in a Laboratory Measurement Room.

    PubMed

    Blanco-Rodríguez, Patricia; Fernández-Serantes, Luis Alfonso; Otero-Pazos, Alberto; Calvo-Rolle, José Luis; de Cos Juez, Francisco Javier

    2017-05-11

    Radon gas is the second leading cause of lung cancer, causing thousands of deaths annually. It can be a problem for people or animals in houses, workplaces, schools or any building. Therefore, its mitigation has become essential to avoid health problems and to prevent radon from interfering in radioactive measurements. This study describes the implementation of radon mitigation systems at a radioactivity laboratory in order to reduce interferences in the different works carried out. A large set of radon concentration samples is obtained from measurements at the laboratory. While several mitigation methods were taken into account, the final applied solution is explained in detail, obtaining thus very good results by reducing the radon concentration by 76%.

  10. Co-"Lab"oration: A New Paradigm for Building a Management Information Systems Course

    ERIC Educational Resources Information Center

    Breimer, Eric; Cotler, Jami; Yoder, Robert

    2010-01-01

    We propose a new paradigm for building a Management Information Systems course that focuses on laboratory activities developed collaboratively using Computer-Mediated Communication and Collaboration tools. A highlight of our paradigm is the "practice what you preach" concept where the computer communication tools and collaboration…

  11. Retailing Laboratory: Delivering Skills through Experiential Learning

    ERIC Educational Resources Information Center

    Franco Valdez, Ana Dolores; Valdez Cervantes, Alfonso

    2018-01-01

    Building from a theoretical foundation of active learning, this article describes how using a retail laboratory in an educational curriculum can benefit both students and strategic partners. Students work alongside strategic partners, and the retail laboratory enables them to probe and design novel retailing strategies, such as launching new…

  12. Practical way to develop 10-color flow cytometry protocols for the clinical laboratory

    NASA Astrophysics Data System (ADS)

    Tárnok, Attila; Bocsi, Jozsef

    2010-02-01

    The latest development of commercial routine flow cytometers (FCM) is that they are equipped with three (blue, red, violet) or more lasers and many PMT detectors. Nowadays routine clinical instruments are capable of detecting 10 or more fluorescence colors simultaneously. Thereby, presenting opportunities for getting detailed information on the single cell level for cytomics and systems biology for improve diagnostics and monitoring of patients. The University Leipzig, Germany) recently started a cluster of excellence to study the molecular background of life style and environment associated diseases, enrolling 25000 individuals (LIFE). To this end the most comprehensive FCM protocol has to be developed for this study. We aimed to optimize fluorochrome and antibody combinations to the characteristics of the instrument for successful 10-color FCM. Systematic review of issues related to sampling, preparation, instrument settings, spillover and compensation matrix, reagent performance, and general principles of panel construction was performed. 10-color FCM enables for increased accuracy in cell subpopulation identification, the ability to obtain detailed information from blood specimens, improved laboratory efficiency, and the means to consistently detect major and rare cell populations. Careful attention to details of instrument and reagent performance allows for the development of panels suitable for screening of samples from healthy and diseased donors. The characteristics of this technique are particularly well suited for the analysis of broad human population cohorts and have the potential to reach the everyday practice in a standardized way for the clinical laboratory.

  13. 1. OVERALL VIEW OF BUILDING 9, LOOKING TO SOUTHEAST FROM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. OVERALL VIEW OF BUILDING 9, LOOKING TO SOUTHEAST FROM BUILDING 4. BUILDING 2 IS VISIBLE BEHIND AND TO LEFT OF BUILDING 9. - U.S. Geological Survey, Rock Magnetics Laboratory, 345 Middlefield Road, Menlo Park, San Mateo County, CA

  14. An image, looking southeast down the passage between E Building ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    An image, looking southeast down the passage between E Building and M Building immediately to the east. The east entrance and the south wing of the building are visible - Department of Energy, Mound Facility, Electronics Laboratory Building (E Building), One Mound Road, Miamisburg, Montgomery County, OH

  15. Golden Laboratories and Offices | NREL

    Science.gov Websites

    most research laboratories are located at our campus in Golden, Colorado, north of highway I-70 and Renewable Energy Laboratory 15013 Denver West Parkway Golden, CO 80401 303-275-3000 GPS Coordinates 39 your trip. Security Procedures Visitors must check in at the Site Entrance Building. Please see

  16. 24. PHOTOCOPY OF PLAN DRAWING. Quartermaster Research and Development Laboratory, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. PHOTOCOPY OF PLAN DRAWING. Quartermaster Research and Development Laboratory, Natick, Mass, Climatic Building, First Floor Plan, Architectural. Drawing No. 35-07-01, Sheet 2 of 72, 1952, updated to 1985. (Source: NRDEC). - Natick Research & Development Laboratories, Climatic Chambers Building, U.S. Army Natick Research, Development & Engineering Center (NRDEC), Natick, Middlesex County, MA

  17. 25. PHOTOCOPY OF PLAN DRAWING. Quartermaster Research and Development Laboratory, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    25. PHOTOCOPY OF PLAN DRAWING. Quartermaster Research and Development Laboratory, Natick, Mass. Climatic Building, First Floor Plan, Refrigeration and Engineering. Drawing No. 35-07-01, Sheet 52 of 72, 1952. (Source: NRDEC). - Natick Research & Development Laboratories, Climatic Chambers Building, U.S. Army Natick Research, Development & Engineering Center (NRDEC), Natick, Middlesex County, MA

  18. Inverter testing at Sandia National Laboratories

    NASA Astrophysics Data System (ADS)

    Ginn, Jerry W.; Bonn, Russell H.; Sittler, Greg

    1997-02-01

    Inverters are key building blocks of photovoltaic (PV) systems that produce ac power. The balance of systems (BOS) portion of a PV system can account for up to 50% of the system cost, and its reliable operation is essential for a successful PV system. As part of its BOS program, Sandia National Laboratories (SNL) maintains a laboratory wherein accurate electrical measurements of power systems can be made under a variety of conditions. This paper outlines the work that is done in that laboratory.

  19. HOT CELL BUILDING, TRA632. EAST END OF BUILDING. CAMERA FACING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    HOT CELL BUILDING, TRA-632. EAST END OF BUILDING. CAMERA FACING WEST. TRUCK ENCLOSURE (1986) TO THE LEFT, SMALL ADDITION IN ITS SHADOW IS ENCLOSURE OVER METAL PORT INTO HOT CELL NO. 1 (THE OLDEST HOT CELL). NOTE PERSONNEL LADDER AND PLATFORM AT LOFT LEVEL USED WHEN SERVICING AIR FILTERS AND VENTS OF CELL NO. 1. INL NEGATIVE NO. HD46-32-4. Mike Crane, Photographer, 4/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  20. Phlebotomy, a bridge between laboratory and patient

    PubMed Central

    Ialongo, Cristiano; Bernardini, Sergio

    2016-01-01

    The evidence-based paradigm has changed and evolved medical practice. Phlebotomy, which dates back to the age of ancient Greece, has gained experience through the evolution of medicine becoming a fundamental diagnostic tool. Nowadays it connects the patient with the clinical laboratory dimension building up a bridge. However, more often there is a gap between laboratory and phlebotomist that causes misunderstandings and burdens on patient safety. Therefore, the scope of this review is delivering a view of modern phlebotomy to “bridge” patient and laboratory. In this regard the paper describes devices, tools and procedures in the light of the most recent scientific findings, also discussing their impact on both quality of blood testing and patient safety. It also addresses the issues concerning medical aspect of venipuncture, like the practical approach to the superficial veins anatomy, as well as the management of the patient’s compliance with the blood draw. Thereby, the clinical, technical and practical issues are treated with the same relevance throughout the entire paper. PMID:26981016