Sample records for laboratory findings including

  1. [Laboratory findings in patients with hemorrhagic fever with renal syndrome].

    PubMed

    Puljiz, Ivan; Kuzman, Ilija; Turcinov, Drago; Makek, Nikola; Markotić, Alemka

    2005-01-01

    To examine the frequency and distribution of hematologic and biochemical laboratory findings in 94 patients with hemorrhagic fever with renal syndrome (HFRS) in the epidemic year 2002. The following laboratory findings were retrospectively analyzed: erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), hemoglobin, hematocrit, leukocyte count and differential percentage (segmented neutrophils, band neutrophils, atypical lymphocytes), platelet count, coagulation tests, blood urea nitrogen (BUN), creatinine, urine, potassium, bilirubin (BIL), aspartate aminotransferase (AST), alanine aminotransferase (ALT), gamma-glutamyltransferase (GT), alkaline phosphatase (ALP), and serum protein electrophoresis. The study included 94 HFRS patients treated at the Dr Fran Mihaljević University Hospital for Infectious Diseases in Zagreb during 2002. ESR increase, mostly mild to moderate, was found in 86.2% of study patients. Increased CRP was recorded in 98.9% of study patients, however, one-fourth had CRP higher than 100 mg/L. Leukocytosis was recorded in 38.3% (10.1 +/- 4.2 x 10(9)/L), thrombocytopenia in 89.4% patients (68.2 +/- 48.3 x 10(9)/L), and severe thrombocytopenia (x 10(9)/L) in six patients. Three patients had abnormal coagulation tests. Increased values of BUN and creatinine were recorded in more than a half of patients, while only four patients had mild hyperkalemia. Only three patinets required hemodialysis. Mildly to moderately increased values of aminotransferases (AST, ALT, GT) were observed in more than 2/3; hypoalbuminaemia in nearly 1/3, and elevated alpha-2 fraction in more than 2/3 of patients. The majority of patients had pathologic urine findings. First laboratory abnormalities were usually found between day 5 and 7 of the disease (increased CRP level, thrombocytopenia, leukocytosis, and elevation of hemoglobin and hematocrit). Biochemical abnormalities(elevation of cratinine and urea, increased levels of aminotransferases) usually occurred at

  2. Clinical, laboratory, and hemostatic findings in cats with naturally occurring sepsis.

    PubMed

    Klainbart, Sigal; Agi, Limor; Bdolah-Abram, Tali; Kelmer, Efrat; Aroch, Itamar

    2017-11-01

    OBJECTIVE To characterize clinical and laboratory findings in cats with naturally occurring sepsis, emphasizing hemostasis-related findings, and evaluate these variables for associations with patient outcomes. DESIGN Prospective, observational, clinical study. ANIMALS 31 cats with sepsis and 33 healthy control cats. PROCEDURES Data collected included history; clinical signs; results of hematologic, serum biochemical, and hemostatic tests; diagnosis; and outcome (survival vs death during hospitalization or ≤ 30 days after hospital discharge). Differences between cats with and without sepsis and associations between variables of interest and death were analyzed statistically. RESULTS The sepsis group included cats with pyothorax (n = 10), septic peritonitis (7), panleukopenia virus infection (5), bite wounds (5), abscesses and diffuse cellulitis (3), and pyometra (1). Common clinical abnormalities included dehydration (21 cats), lethargy (21), anorexia (18), pale mucous membranes (15), and dullness (15). Numerous clinicopathologic abnormalities were identified in cats with sepsis; novel findings included metarubricytosis, hypertriglyceridemia, and high circulating muscle enzyme activities. Median activated partial thromboplastin time and plasma D-dimer concentrations were significantly higher, and total protein C and antithrombin activities were significantly lower, in the sepsis group than in healthy control cats. Disseminated intravascular coagulopathy was uncommon (4/22 [18%] cats with sepsis). None of the clinicopathologic abnormalities were significantly associated with death on multivariate analysis. CONCLUSIONS AND CLINICAL RELEVANCE Cats with sepsis had multiple hematologic, biochemical, and hemostatic abnormalities on hospital admission, including several findings suggestive of hemostatic derangement. Additional research including larger numbers of cats is needed to further investigate these findings and explore associations with outcome.

  3. Understanding variations in secondary findings reporting practices across U.S. genome sequencing laboratories.

    PubMed

    Ackerman, Sara L; Koenig, Barbara A

    2018-01-01

    Increasingly used for clinical purposes, genome and exome sequencing can generate clinically relevant information that is not directly related to the reason for testing (incidental or secondary findings). Debates about the ethical implications of secondary findings were sparked by the American College of Medical Genetics (ACMG) 2013 policy statement, which recommended that laboratories report pathogenic alterations in 56 genes. Although wide variation in laboratories' secondary findings policies has been reported, little is known about its causes. We interviewed 18 laboratory directors and genetic counselors at 10 U.S. laboratories to investigate the motivations and interests shaping secondary findings reporting policies for clinical exome sequencing. Analysis of interview transcripts and laboratory documents was informed by sociological theories of standardization. Laboratories varied widely in terms of the types of secondary findings reported, consent-form language, and choices offered to patients. In explaining their adaptation of the ACMG report, our participants weighed genetic information's clinical, moral, professional, and commercial value in an attempt to maximize benefits for patients and families, minimize the costs of sequencing and analysis, adhere to professional norms, attract customers, and contend with the uncertain clinical implications of much of the genetic information generated. Nearly all laboratories in our study voluntarily adopted ACMG's recommendations, but their actual practices varied considerably and were informed by laboratory-specific judgments about clinical utility and patient benefit. Our findings offer a compelling example of standardization as a complex process that rarely leads simply to uniformity of practice. As laboratories take on a more prominent role in decisions about the return of genetic information, strategies are needed to inform patients, families, and clinicians about the differences between laboratories' practices

  4. Clinical manifestations and laboratory findings of 496 children with brucellosis in Van, Turkey.

    PubMed

    Parlak, Mehmet; Akbayram, Sinan; Doğan, Murat; Tuncer, Oğuz; Bayram, Yasemin; Ceylan, Nesrin; Özlük, Suat; Akbayram, Hatice Tuba; Öner, Abdurrahman

    2015-08-01

    Brucellosis is the most common zoonotic disease worldwide and remains an important human disease especially in developing countries. The aim of the present study was to evaluate clinical manifestations and laboratory findings of childhood brucellosis in Van province of Eastern Turkey. To our knowledge, this is the largest series of childhood brucellosis reported in the literature. In this retrospective study, 496 children with brucellosis were assessed for the clinical manifestations and laboratory findings from July 2009 through December 2013. The diagnosis of brucellosis was based on clinical findings and a standard tube agglutination test (titer ≥ 1:160). Data were analyzed using Minitab version 16. The study included 496 children (boys, 60.5%) with a mean age of 10.0 ± 3.95 years (range, 1-16 years). The most frequent clinical symptoms were arthralgia (46.2%), fever (32.1%), and abdominal pain (17.1%) and the most common clinical signs were peripheral arthritis (10.1%), splenomegaly (2.2%) and hepatomegaly (1.8%). The most contagious seasons were summer and autumn (63.3%). Elevated lactate dehydrogenase and C-reactive protein and erythrocyte sedimentation rate were reported in 63.1%, 58.7%, and 55.2% of the patients, respectively. Anemia (20.4%), thrombocytopenia (15.5%), and leukopenia (12.1%) were the most common hematologic findings. Brucellosis remains a serious public health problem in Turkey. The clinical and laboratory characteristics of childhood brucellosis have been described in order to assist clinicians in diagnosing and monitoring the disease. © 2015 Japan Pediatric Society.

  5. 40 CFR 262.105 - What must be included in the laboratory environmental management plan?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... University Laboratories XL Project-Laboratory Environmental Management Standard § 262.105 What must be included in the laboratory environmental management plan? (a) Each University must include specific... laboratory environmental management plan? 262.105 Section 262.105 Protection of Environment ENVIRONMENTAL...

  6. Oropharyngeal Dysphagia in Dermatomyositis: Associations with Clinical and Laboratory Features Including Autoantibodies

    PubMed Central

    Mugii, Naoki; Hasegawa, Minoru; Matsushita, Takashi; Hamaguchi, Yasuhito; Oohata, Sacihe; Okita, Hirokazu; Yahata, Tetsutarou; Someya, Fujiko; Inoue, Katsumi; Murono, Shigeyuki; Fujimoto, Manabu; Takehara, Kazuhiko

    2016-01-01

    Objective Dysphagia develops with low frequency in patients with dermatomyositis. Our objective was to determine the clinical and laboratory features that can estimate the development of dysphagia in dermatomyositis. Methods This study included 92 Japanese patients with adult-onset dermatomyositis. The associations between dysphagia and clinical and laboratory features including disease-specific autoantibodies determined by immunoprecipitation assays were analyzed. Results Videofluoroscopy swallow study (VFSS) was performed for all patients with clinical dysphagia (n = 13, 14.1%) but not for patients without clinical dysphagia. Typical findings of dysphagia (pharyngeal pooling, n = 11 and/or nasal regurgitation, n = 4) was detected by VFSS in all patients with clinical dysphagia. Eleven patients with dysphagia (84.6%) had anti-transcription intermediary factor 1γ (TIF-1γ) antibody. By univariate analysis, the average age and the male to female ratio, internal malignancy, and anti-TIF-1γ antibody were significantly higher and the frequency of interstitial lung diseases and manual muscle testing (MMT) scores of sternomastoid and dertoid muscles were significantly lower in patients with dysphagia than in patients without dysphagia. Among patients with anti-TIF-1γ antibody, the mean age, the ratios of male to female and internal malignancy were significantly higher and mean MMT scores of sternomastoid muscle were significantly lower in patients with dysphagia compared with patients without dysphagia. By multivariable analysis, the risk of dysphagia was strongly associated with the existence of internal malignancy and ant-TIF-1γ antibody and was also associated with reduced scores of manual muscle test of sternomastoid muscle. Dysphagia was markedly improved after the treatment against myositis in all 13 patients. Conclusion These findings indicate that dysphagia can develop frequently in patients with internal malignancy, anti-TIF-1γ antibody, or severe muscle

  7. Oropharyngeal Dysphagia in Dermatomyositis: Associations with Clinical and Laboratory Features Including Autoantibodies.

    PubMed

    Mugii, Naoki; Hasegawa, Minoru; Matsushita, Takashi; Hamaguchi, Yasuhito; Oohata, Sacihe; Okita, Hirokazu; Yahata, Tetsutarou; Someya, Fujiko; Inoue, Katsumi; Murono, Shigeyuki; Fujimoto, Manabu; Takehara, Kazuhiko

    2016-01-01

    Dysphagia develops with low frequency in patients with dermatomyositis. Our objective was to determine the clinical and laboratory features that can estimate the development of dysphagia in dermatomyositis. This study included 92 Japanese patients with adult-onset dermatomyositis. The associations between dysphagia and clinical and laboratory features including disease-specific autoantibodies determined by immunoprecipitation assays were analyzed. Videofluoroscopy swallow study (VFSS) was performed for all patients with clinical dysphagia (n = 13, 14.1%) but not for patients without clinical dysphagia. Typical findings of dysphagia (pharyngeal pooling, n = 11 and/or nasal regurgitation, n = 4) was detected by VFSS in all patients with clinical dysphagia. Eleven patients with dysphagia (84.6%) had anti-transcription intermediary factor 1γ (TIF-1γ) antibody. By univariate analysis, the average age and the male to female ratio, internal malignancy, and anti-TIF-1γ antibody were significantly higher and the frequency of interstitial lung diseases and manual muscle testing (MMT) scores of sternomastoid and dertoid muscles were significantly lower in patients with dysphagia than in patients without dysphagia. Among patients with anti-TIF-1γ antibody, the mean age, the ratios of male to female and internal malignancy were significantly higher and mean MMT scores of sternomastoid muscle were significantly lower in patients with dysphagia compared with patients without dysphagia. By multivariable analysis, the risk of dysphagia was strongly associated with the existence of internal malignancy and ant-TIF-1γ antibody and was also associated with reduced scores of manual muscle test of sternomastoid muscle. Dysphagia was markedly improved after the treatment against myositis in all 13 patients. These findings indicate that dysphagia can develop frequently in patients with internal malignancy, anti-TIF-1γ antibody, or severe muscle weakness of sternomastoid muscle.

  8. The utility of clinical findings to predict laboratory values in hypertensive disorders of pregnancy.

    PubMed

    So, Jane; Young, Elizabeth; Crnosija, Natalie; Chappelle, Joseph

    2016-04-01

    Preeclampsia is the 2nd leading cause of maternal mortality in the United States. Women with new-onset or worsening hypertension are commonly evaluated for laboratory abnormalities. We aim to investigate whether demographic and/or clinical findings correlate with abnormal laboratory values. A retrospective chart review of women who presented for evaluation of hypertension in pregnancy during 2010. Demographic information, medical history, symptoms, vital signs, and laboratory results were collected. Bivariate analysis was used to investigate associations between predictors and the outcome. Of the 481 women in the sample, 22 were identified as having abnormal laboratory test results (4.6%). Women who reported right upper quadrant pain or tenderness had significantly increased likelihood of having laboratory abnormalities compared to those without the complaint. Only a small percentage of women evaluated were determined to have abnormal laboratory findings, predominantly among women with severe preeclampsia. Right upper quadrant pain or tenderness was positively correlated with laboratory abnormalities. The restriction of laboratory analysis in women with clinical evidence of severe disease may be warranted - a broader study should, however, first be used to confirm our findings.

  9. Evaluation of clinical, laboratory, imaging findings and outcome in 99 dogs with leptospirosis.

    PubMed

    Knöpfler, S; Mayer-Scholl, A; Luge, E; Klopfleisch, R; Gruber, A D; Nöckler, K; Kohn, B

    2017-10-01

    To report clinical, laboratory and diagnostic imaging features and prognostic factors in dogs with leptospirosis from North-East Germany. Medical records of dogs diagnosed with leptospirosis from 2006 to 2013 were evaluated retrospectively. The study included 99 dogs. At initial presentation, the most common clinical signs were lethargy (96%), anorexia (88%), vomiting (85%), painful abdomen (39%), diarrhoea (38%), oliguria (27%) and tachypnoea (26%). Abnormal laboratory findings included anaemia (63%), thrombocytopenia (63%), leucocytosis (57%), increase of plasma urea (84%) and creatinine concentrations (81%), increased liver enzyme activities (80%), hyperbilirubinaemia (69%), hyperphosphataemia (67%), hyponatraemia (64%), hypoalbuminaemia (55%) and hypokalaemia (29%). Radiological pulmonary changes were detected in 57% of the dogs initially or during the course of disease. Severe dyspnoea, oliguria, azotaemia, hyperbilirubinaemia and severe radiological pulmonary changes were more often found in dogs that did not survive. There was renal, hepatic and pulmonary involvement in 95, 92 and 58% of the dogs, respectively, and multi-organ lesions in 98 dogs (98%); 32 dogs died or were euthanased. Several clinical and laboratory abnormalities were associated with a negative outcome; severe lung involvement was specifically associated with high mortality. © 2017 British Small Animal Veterinary Association.

  10. 20 CFR 220.113 - Symptoms, signs, and laboratory findings.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 1 2010-04-01 2010-04-01 false Symptoms, signs, and laboratory findings. 220.113 Section 220.113 Employees' Benefits RAILROAD RETIREMENT BOARD REGULATIONS UNDER THE RAILROAD..., thought, memory, orientation and contact with reality. They must also be shown by observable facts that...

  11. Molindone hydrochloride: a review of laboratory and clinical findings.

    PubMed

    Owen, R R; Cole, J O

    1989-08-01

    Molindone hydrochloride, a dihydroindolone neuroleptic, is structurally distinct from other classes of neuroleptics. Molindone exhibits many similarities to other neuroleptics, including dopamine receptor blockade, antipsychotic efficacy, and extrapyramidal side effects. Despite these similarities, molindone also has atypical properties and inhibits the enzyme monoamine oxidase in vitro and in vivo. Several studies have shown that molindone causes less dopamine receptor supersensitivity than other neuroleptics and thus may be less likely to cause tardive dyskinesia. It also appears to have a greater effect on mesolimbic and mesocortical dopamine neurons than on those in the nigrostriatal dopamine system. Clinically, molindone has a tendency to cause weight loss and may have less effect on seizure threshold than conventional antipsychotic agents. The authors review the laboratory and clinical data on molindone and discuss the relevance of atypical research findings to the clinical characteristics of this antipsychotic agent.

  12. 78 FR 54487 - Abbott Laboratories; Diagnostic-Hematology; Including On-Site Leased Workers From Manpower...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-04

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-82,379] Abbott Laboratories... February 22, 2013, applicable to workers of Abbott Laboratories, Diagnostic--Hematology division, including... Clara, California location of Abbott Laboratories, Diagnostic--Hematology Division. The Department has...

  13. A laboratory medicine residency training program that includes clinical consultation and research.

    PubMed

    Spitzer, E D; Pierce, G F; McDonald, J M

    1990-04-01

    We describe a laboratory medicine residency training program that includes ongoing interaction with both clinical laboratories and clinical services as well as significant research experience. Laboratory medicine residents serve as on-call consultants in the interpretation of test results, design of testing strategies, and assurance of test quality. The consultative on-call beeper system was evaluated and is presented as an effective method of clinical pathology training that is well accepted by the clinical staff. The research component of the residency program is also described. Together, these components provide training in real-time clinical problem solving and prepare residents for the changing technological environment of the clinical laboratory. At the completion of the residency, the majority of the residents are qualified laboratory subspecialists and are also capable of running an independent research program.

  14. Inflammatory myopathies in childhood: correlation between nailfold capillaroscopy findings and clinical and laboratory data.

    PubMed

    Nascif, Ana K S; Terreri, Maria T R A; Len, Cláudio A; Andrade, Luis E C; Hilário, Maria O E

    2006-01-01

    Nailfold capillaroscopy is an important tool for the diagnosis and follow-up of patients with rheumatic diseases, in particular dermatomyositis and scleroderma. A relationship has been observed in adults between improved capillaroscopic findings and reduced disease activity. Our aim was to correlate disease activity (clinical and laboratory data) and nailfold capillaroscopy findings in 18 patients with inflammatory myopathies. This prospective study included 13 juvenile dermatomyositis patients (Bohan and Peter criteria) (mean age of 8.8 years) and five patients with overlap syndrome (mean age of 15.7 years). We evaluated disease activity (skin abnormalities and muscle weakness, muscle enzymes and acute phase reactants) and its correlation with nailfold capillaroscopy findings (dilatation of isolated loops, dropout of surrounding vessels and giant capillary loops). We used a microscope with special light and magnification of 10 to 16X. Eighteen patients underwent a total of 26 capillaroscopic examinations, seven of them on two or more occasions (13 were performed during the active disease phase and 13 during remission). Twelve of the 13 examinations performed during the active phase exhibited scleroderma pattern and 8 of the 13 examinations performed during remission were normal. Therefore, in 20 of the 26 examinations clinical and laboratory data and nailfold capillaroscopy findings correlated (p = 0.01). Nailfold capillaroscopy is a non-invasive examination that offers satisfactory correlation with disease activity and could be a useful tool for the diagnosis and follow-up of inflammatory myopathies.

  15. 77 FR 4368 - Abbott Laboratories, Diagnostics Division, Including On-Site Leased Workers From Manpower...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-27

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-75,201] Abbott Laboratories..., applicable to workers of Abbott Laboratories, Diagnostics Division, including on-site leased workers from... (clerical) were employed on-site at the Irving, Texas location of Abbott Laboratories, Diagnostics Division...

  16. [Reversed clinicopathological conference (R-CPC)--interpreting laboratory data in the same way as physical findings].

    PubMed

    Sugano, Mitsutoshi; Shimada, Masashi; Moriyoshi, Miho; Kitagawa, Kiyoki; Nakashima, Hiromi; Wada, Hideo; Yanagihara, Katsunori; Fujisawa, Shinya; Yonekawa, Osamu; Honda, Takayuki

    2012-05-01

    Routine laboratory data are discussed by time series analysis in reversed clinicopathological conferences (R-CPC) at Shinshu University School of Medicine. We can identify fine changes in the laboratory data and the importance of negative data (without any changes) using time series analysis. Routine laboratory tests can be performed repeatedly and relatively cheaply, and time series analysis can be performed. The examination process of routine laboratory data in the R-CPC is almost the same as the process of taking physical findings. Firstly, general findings are checked and then the state of each organ is examined. Although routine laboratory data are cheap, we can obtain much more information about a patient's state than from physical examinations. In this R-CPC, several specialists in the various fields of laboratory medicine discussed the routine laboratory data of a patient, and we tried to understand the detailed state of the patient. R-CPC is an educational method to examine laboratory data and we, reconfirmed the usefulness of R-CPC to elucidate the clinical state of the patient.

  17. Clinical presentation and laboratory findings for the first autochthonous cases of dengue fever in Madeira island, Portugal, October 2012.

    PubMed

    Alves, M J; Fernandes, P L; Amaro, F; Osório, H; Luz, T; Parreira, P; Andrade, G; Zé-Zé, L; Zeller, H

    2013-02-07

    An outbreak of dengue fever in Madeira island was reported in 2012. Clinical and laboratory findings of the first two laboratory-confirmed autochthonous cases are reported. Both cases had fever (≥38 °C) and petechial rash. Symptoms also included myalgia, asthenia, nausea, vomiting, anorexia, diffuse abdominal pain, and diarrhoea. The two cases were confirmed by serology and one tested positive for a dengue viral sequence. Dengue virus serotype DEN-1 was identified with probable Central or South American origin.

  18. [Subclinical hypothyroidism - laboratory finding or disease?].

    PubMed

    Voigtländer, Richard; Führer, Dagmar

    2016-08-01

    Subclinical hypothyroidism first of all is a laboratory finding, defined by elevated TSH and normal peripheral thyroxine concentrations. The first steps are to verify the condition and to clarify whether the patient has underlying thyroid disease or other comorbidities. Results of recent studies on subclinical hypothyroidism are reassuring. No consistent association has been demonstrated between mildly elevated TSH levels (5-10 mIU / l) and cardiovascular events, mortality, fracture risk or cognitive impairment. In contrast TSH levels between 5-10 mIU / l may even confer lower mortality in the elderly and may hence be protective. These data strongly suggest that the long-time controversy on definition of normal upper TSH levels should take a more conservative turn. Thus, diagnosis of subclinical hypothyroidism should be handled cautiously. Individualized treatment decision is recommended if TSH levels are only mildly elevated and less than 8-10 mIU / l. In case of autoimmune thyroiditis or previous thyroid therapy (surgery, radioiodine treatment) the risk of progression to overt hypothyroidism has to be considered and there is no doubt that the latter should be avoided. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Clinical symptoms and laboratory findings supporting early diagnosis of Crimean-Congo hemorrhagic fever in Iran.

    PubMed

    Mostafavi, Ehsan; Pourhossein, Behzad; Chinikar, Sadegh

    2014-07-01

    Crimean-Congo hemorrhagic fever (CCHF) is a zoonotic disease, which is usually transmitted to humans by tick bites or contact with blood or other infected tissues of livestock. Patients suffering from CCHF demonstrate an extensive spectrum of clinical symptoms. As it can take considerable time from suspecting the disease in hospital until reaching a definitive diagnosis in the laboratory, understanding the clinical symptoms and laboratory findings of CCHF patients is of paramount importance for clinicians. The data were collected from patients who were referred to the Laboratory of Arboviruses and Viral Hemorrhagic Fevers at the Pasteur institute of Iran with a primary diagnosis of CCHF between 1999 and 2012 and were assessed by molecular and serologic tests. Referred patients were divided into two groups: patients with a CCHF positive result and patients with a CCHF negative result. The laboratory and clinical findings of these two groups were then compared. Two-thousand five hundred thirty-six probable cases of CCHF were referred to the laboratory, of which 871 cases (34.3%) were confirmed to be CCHF. Contact with infected humans and animals increased the CCHF infection risk (P < 0.001). A tick bite was not a risk factor. Fever; bleeding, vomiting, leucopoenia, thrombocytopenia, and increases in alanine transaminase (ALT) and aspartate transaminase (AST) levels were also indicative of CCHF infection. Accurate and speedy diagnosis of CCHF and appropriate treatment play an important role in patient survival and the application of the findings of this study can prove helpful as a key for early diagnosis. © 2014 Wiley Periodicals, Inc.

  20. Clinical features and laboratory findings of dengue fever in German travellers: A single-centre, retrospective analysis.

    PubMed

    Tavakolipoor, Pulad; Schmidt-Chanasit, Jonas; Burchard, Gerd Dieter; Jordan, Sabine

    2016-01-01

    Dengue fever (DF) is one of the most relevant human arboviral infections worldwide and has become a frequent cause of fever in the returning traveller. This retrospective study aimed to characterize epidemiological and clinical features and laboratory findings of dengue fever in German travellers. This descriptive study analyzed medical records of patients diagnosed with DF presenting at the Section of Tropical Medicine of the University Medical Centre Hamburg-Eppendorf from 2007 to 2011. Data were collected and analyzed retrospectively. In total, data of 119 DF patients (52 female, 67 male) were included in this study. The median age of the patients was 35 (range 15-75 years). DF was most frequently acquired in South-East Asia (n = 65; 54.7%), and in particular in Thailand (n = 23; 19.7%). A considerable percentage of DF infections (n = 14; 11.8%) was imported from Africa. Patients predominantly presented with fever, headache, rash, myalgia and arthralgia but also with gastrointestinal symptoms, i.e. diarrhoea. Nine patients showed signs of minor haemorrhagic manifestations. Neurological complications occurred in 13 patients. Low platelet count, leukopenia and elevated liver enzymes were the most relevant laboratory findings. Twenty patients (17.8%) had to be hospitalized. Overall, the clinical course was mostly mild to moderate, 13 patients (10.9%) showed DF warnings signs, no fatalities occurred. DF presented as a mostly mild to moderate disease in this study cohort. Outpatient treatment was adequate for the majority of patients. Still, detailed knowledge of clinical symptoms and laboratory features is essential for appropriate triage. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Inter-laboratory comparison of the in vivo comet assay including three image analysis systems.

    PubMed

    Plappert-Helbig, Ulla; Guérard, Melanie

    2015-12-01

    To compare the extent of potential inter-laboratory variability and the influence of different comet image analysis systems, in vivo comet experiments were conducted using the genotoxicants ethyl methanesulfonate and methyl methanesulfonate. Tissue samples from the same animals were processed and analyzed-including independent slide evaluation by image analysis-in two laboratories with extensive experience in performing the comet assay. The analysis revealed low inter-laboratory experimental variability. Neither the use of different image analysis systems, nor the staining procedure of DNA (propidium iodide vs. SYBR® Gold), considerably impacted the results or sensitivity of the assay. In addition, relatively high stability of the staining intensity of propidium iodide-stained slides was found in slides that were refrigerated for over 3 months. In conclusion, following a thoroughly defined protocol and standardized routine procedures ensures that the comet assay is robust and generates comparable results between different laboratories. © 2015 Wiley Periodicals, Inc.

  2. Predicting tularemia with clinical, laboratory and demographical findings in the ED.

    PubMed

    Yapar, Derya; Erenler, Ali Kemal; Terzi, Özlem; Akdoğan, Özlem; Ece, Yasemin; Baykam, Nurcan

    2016-02-01

    We aimed to determine clinical, laboratory and demographical characteristics of tularemia on admission to Emergency Department (ED). Medical data of 317 patients admitted to ED and subsequently hospitalized with suspected tularemia between January 1, 2011, and May 31, 2015, were collected. Patients were divided into 2 groups according to microagglutination test results, as tularemia (+) and tularemia (-). Of the 317 patients involved, 49 were found to be tularemia (+) and 268 were tularemia (-). Mean age of the tularemia (+) patients was found to be higher than that of tularemia (-) patients. When compared to tularemia (-) patients, a significant portion of patients in tularemia (+) patients were elderly, living in rural areas and had contact with rodents. When clinical and laboratory findings of the 2 groups were compared, any statistical significance could not be determined. Tularemia is a disease of elderly people living in rural areas. Contact with rodents also increases risk of tularemia in suspected patients. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Nitroaromatic carcinogens in diesel soot: a review of laboratory findings.

    PubMed Central

    Wei, E T; Shu, H P

    1983-01-01

    The automobile industry plans to increase production of diesel-powered passenger cars because diesel engines provide better fuel economy than conventional gasoline engines. Diesel engines, however, produce more soot, and increased use of diesel cars will result in more discharge of diesel soot into the atmosphere. Recently, a new class of chemicals, called nitroaromatic compounds, have been identified in chemical extracts of diesel soot. Some of these nitroaromatic compounds produce mutations when tested in in vitro bacterial and mammalian cell assays, and cancer when tested in animals. Here, we review the relevance of these new laboratory findings to current deliberations over emission standards for particles from diesel cars. PMID:6192732

  4. Respiratory Findings in Dental Laboratory Technicians in Rasht (North of Iran)

    PubMed Central

    Shakiba, Maryam; Nejad, Azita Tangestani; Massahnia, Sara; Shiari, Ali

    2011-01-01

    Background There are several occupations that can expose people to some air pollutants. Dental technicians are exposed to inorganic dust and chemical vapors when making dental prosthesis that can put them at risk for respiratory problems. This study was performed to assess respiratory dysfunction in a group of dental technicians Materials and Methods This was a cross-sectional study designed to ascertain the prevalence of respiratory disorders in dental laboratory technicians in Rasht, a city located in north of Iran. A Structured questionnaire was adapted according to the European Community Respiratory Health Survey questionnaire and used to elicit information regarding sociodemographic characteristics and medical status of the study participants. The ventilation status, protective measures and direct exposure to materials in the laboratories were directly observed by the observers and subjects underwent respiratory tests and chest x-ray. Results The mean age of dental technicians was 31.31 yrs (range 18-56 years) and 83% were males with a mean dental work experience of 9.04 years. In 54.8% of cases, the work environment did not have air conditioning system. The most common signs and symptoms were cough (38.1%) and wheezing (16.7%). There was a significant correlation between smoking and respiratory signs. Restrictive airway pattern and air trapping were two prevalent findings which were observed in 85.7% and 33.3% of the subjects. Cigarette smoking had a negative effect on FEV1, FEF25%-75%, and TLC causing a significant reduction in all three parameters (p < 0.05). The most prevalent finding was interstitial opacity which was observed in 10 individuals (23.8%). This finding was not significantly associated with age, gender, cigarette smoking, or daily work hours. However, there was a significant statistical association between work experience and interstitial opacity. Conclusion The prevalence of respiratory dysfunction and chest x-ray findings were high as in

  5. [ISO 15189 medical laboratory accreditation].

    PubMed

    Aoyagi, Tsutomu

    2004-10-01

    This International Standard, based upon ISO/IEC 17025 and ISO 9001, provides requirements for competence and quality that are particular to medical laboratories. While this International Standard is intended for use throughout the currently recognized disciplines of medical laboratory services, those working in other services and disciplines will also find it useful and appropriate. In addition, bodies engaged in the recognition of the competence of medical laboratories will be able to use this International Standard as the basis for their activities. The Japan Accreditation Board for Conformity Assessment (AB) and the Japanese Committee for Clinical Laboratory Standards (CCLS) are jointly developing the program of accreditation of medical laboratories. ISO 15189 requirements consist of two parts, one is management requirements and the other is technical requirements. The former includes the requirements of all parts of ISO 9001, moreover it includes the requirement of conformity assessment body, for example, impartiality and independence from any other party. The latter includes the requirements of laboratory competence (e.g. personnel, facility, instrument, and examination methods), moreover it requires that laboratories shall participate proficiency testing(s) and laboratories' examination results shall have traceability of measurements and implement uncertainty of measurement. Implementation of ISO 15189 will result in a significant improvement in medical laboratories management system and their technical competence. The accreditation of medical laboratory will improve medical laboratory service and be useful for patients.

  6. High laboratory cost predicted per tuberculosis case diagnosed with increased case finding without a triage strategy.

    PubMed

    Dunbar, R; Naidoo, P; Beyers, N; Langley, I

    2017-09-01

    Cape Town, South Africa. To model the effects of increased case finding and triage strategies on laboratory costs per tuberculosis (TB) case diagnosed. We used a validated operational model and published laboratory cost data. We modelled the effect of varying the proportion with TB among presumptive cases and Xpert cartridge price reductions on cost per TB case and per additional TB case diagnosed in the Xpert-based vs. smear/culture-based algorithms. In our current scenario (18.3% with TB among presumptive cases), the proportion of cases diagnosed increased by 8.7% (16.7% vs. 15.0%), and the cost per case diagnosed increased by 142% (US$121 vs. US$50). The cost per additional case diagnosed was US$986. This would increase to US$1619 if the proportion with TB among presumptive cases was 10.6%. At 25.9-30.8% of TB prevalence among presumptive cases and a 50% reduction in Xpert cartridge price, the cost per TB case diagnosed would range from US$50 to US$59 (comparable to the US$48.77 found in routine practice with smear/culture). The operational model illustrates the effect of increased case finding on laboratory costs per TB case diagnosed. Unless triage strategies are identified, the approach will not be sustainable, even if Xpert cartridge prices are reduced.

  7. Developing Methodologies to Find Abbreviated Laboratory Test Names in Narrative Clinical Documents by Generating High Quality Q-Grams.

    PubMed

    Kim, Kyungmo; Choi, Jinwook

    2017-01-01

    Laboratory test names are used as basic information to diagnose diseases. However, this kind of medical information is usually written in a natural language. To find this information, lexicon based methods have been good solutions but they cannot find terms that do not have abbreviated expressions, such as "neuts" that means "neutrophils". To address this issue, similar word matching can be used; however, it can be disadvantageous because of significant false positives. Moreover, processing time is longer as the size of terms is bigger. Therefore, we suggest a novel q-gram based algorithm, named modified triangular area filtering, to find abbreviated laboratory test terms in clinical documents, minimizing the possibility to impair the lexicons' precision. In addition, we found the terms using the methodology with reasonable processing time. The results show that this method can achieve 92.54 precision, 87.72 recall, 90.06 f1-score in test sets when edit distance threshold(τ) = 3.

  8. Clinical and laboratory findings of rhabdomyolysis in opioid overdose patients in the intensive care unit of a poisoning center in 2014 in Iran

    PubMed Central

    Babak, Khoshideh; Mohammad, Arefi; Mazaher, Ghorbani; Fatemeh, Taghizadeh

    2017-01-01

    OBJECTIVES The aim of this study was to investigate the clinical and demographic characteristics and some laboratory findings of hospitalized patients with acute opioid toxicity and rhabdomyolysis. METHODS This cross-sectional study investigated 354 patients hospitalized at Baharloo Hospital in Tehran in 2014 with acute illicit drug toxicity. Data were collected using an investigator-made checklist. The collected data (such as mortality rate, demographic data, and renal function tests, as well as serum biochemical findings) were analyzed by descriptive statistics and the chi-square test. RESULTS A total of 354 patients were admitted to the hospital in 2014 with acute illicit drug toxicity, including 291 males and 63 females. The total number of patients with rhabdomyolysis was 76 (21.5% of the total), of whom 69 (90.8%) were male and 7 (9.2%) were female. Most cases of rhabdomyolysis were associated with methadone abuse, followed by opium abuse. Rhabdomyolysis was most common in those 20-29 and 30-39 years old, with methadone and opium the most commonly abused illicit drugs. The mean blood urea level was 3.8±1.0 mg/dL, and the mean serum potassium and sodium levels were 3.8±0.3 mg/dL and 140.4±4.0 mg/dL, respectively. Five patients, all of whom were male, passed away due to severe renal failure (6.5%). CONCLUSIONS Toxicity caused by opioids is associated with clinical complications and laboratory disorders, such as electrolyte disorders, which can lead to lethal or life-threatening results in some cases. Abnormal laboratory test findings should be identified in patients with opioid toxicity in order to initiate efficient treatment. PMID:29121712

  9. Clinical and laboratory findings of rhabdomyolysis in opioid overdose patients in the intensive care unit of a poisoning center in 2014 in Iran.

    PubMed

    Babak, Khoshideh; Mohammad, Arefi; Mazaher, Ghorbani; Samaneh, Akbarpour; Fatemeh, Taghizadeh

    2017-01-01

    The aim of this study was to investigate the clinical and demographic characteristics and some laboratory findings of hospitalized patients with acute opioid toxicity and rhabdomyolysis. This cross-sectional study investigated 354 patients hospitalized at Baharloo Hospital in Tehran in 2014 with acute illicit drug toxicity. Data were collected using an investigator-made checklist. The collected data (such as mortality rate, demographic data, and renal function tests, as well as serum biochemical findings) were analyzed by descriptive statistics and the chi-square test. A total of 354 patients were admitted to the hospital in 2014 with acute illicit drug toxicity, including 291 males and 63 females. The total number of patients with rhabdomyolysis was 76 (21.5% of the total), of whom 69 (90.8%) were male and 7 (9.2%) were female. Most cases of rhabdomyolysis were associated with methadone abuse, followed by opium abuse. Rhabdomyolysis was most common in those 20-29 and 30-39 years old, with methadone and opium the most commonly abused illicit drugs. The mean blood urea level was 3.8±1.0 mg/dL, and the mean serum potassium and sodium levels were 3.8±0.3 mg/dL and 140.4±4.0 mg/dL, respectively. Five patients, all of whom were male, passed away due to severe renal failure (6.5%). Toxicity caused by opioids is associated with clinical complications and laboratory disorders, such as electrolyte disorders, which can lead to lethal or life-threatening results in some cases. Abnormal laboratory test findings should be identified in patients with opioid toxicity in order to initiate efficient treatment.

  10. Dental Laboratory Technology. Project Report Phase I with Research Findings.

    ERIC Educational Resources Information Center

    Sappe', Hoyt; Smith, Debra S.

    This report provides results of Phase I of a project that researched the occupational area of dental laboratory technology, established appropriate committees, and conducted task verification. These results are intended to guide development of a program designed to train dental laboratory technicians. Section 1 contains general information:…

  11. Freshwater findings, 1979-1982: research publications of the Environmental Research Laboratory, Duluth, Minnesota

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Highland, T.; Curtis, C.

    1983-10-01

    This report contains citations of publications for the years 1979-1982 on research conducted or supported by the Environmental Research Laboratory-Duluth. All published material has been organized into two major categories: (1) Journal Articles, Book Chapters, Proceedings, etc., and (2) EPA Research Reports. The report is organized by year with all journal articles, book chapters, proceedings, etc., for a given year appearing before the EPA research reports for the same year; within each category publications are listed alphabetically by author. Authors of the publications listed include ERL-Duluth laboratory staff members and scientists at universities, in industry, and at other facilities whomore » received research funding under the auspices of the Environmental Research Laboratory-Duluth. Limited quantities of reprints are available for those articles identified by ERL-Duluth reprint number in parentheses following the citation. These can be obtained by writing to: Librarian, ERL-Duluth, U.S. EPA, 6201 Congdon Boulevard, Duluth, MN 55804. EPA research reports can be obtained by writing to: National Technical Information Service, 5285 Port Royal Road, Springfield, VA 22151. All other articles are not available from ERL-Duluth or NTIS, but can be found in most major libraries.« less

  12. An Integrated Biochemistry Laboratory, Including Molecular Modeling

    NASA Astrophysics Data System (ADS)

    Hall, Adele J. Wolfson Mona L.; Branham, Thomas R.

    1996-11-01

    The dilemma of designing an advanced undergraduate laboratory lies in the desire to teach and reinforce basic principles and techniques while at the same time exposing students to the excitement of research. We report here on a one-semester, project-based biochemistry laboratory that combines the best features of a cookbook approach (high success rate, achievement of defined goals) with those of an investigative, discovery-based approach (student involvement in the experimental design, excitement of real research). Individual modules may be selected and combined to meet the needs of different courses and different institutions. The central theme of this lab is protein purification and design. This laboratory accompanies the first semester of biochemistry (Structure and Function of Macromolecules, a course taken mainly by junior and senior chemistry and biological chemistry majors). The protein chosen as the object of study is the enzyme lysozyme, which is utilized in all projects. It is suitable for a student lab because it is easily and inexpensively obtained from egg white and is extremely stable, and its high isoelectric point (pI = 11) allows for efficient separation from other proteins by ion-exchange chromatography. Furthermore, a literature search conducted by the resourceful student reveals a wealth of information, since lysozyme has been the subject of numerous studies. It was the first enzyme whose structure was determined by crystallography (1). Hendrickson et al. (2) have previously described an intensive one-month laboratory course centered around lysozyme, although their emphasis is on protein stability rather than purification and engineering. Lysozyme continues to be the focus of much exciting new work on protein folding and dynamics, structure and activity (3 - 5). This lab course includes the following features: (i) reinforcement of basic techniques, such as preparation of buffers, simple enzyme kinetics, and absorption spectroscopy; (ii

  13. 20 CFR 220.113 - Symptoms, signs, and laboratory findings.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... are medically demonstrable phenomena which indicate specific abnormalities of behavior, affect... psychological phenomena which can be shown by the use of medically acceptable laboratory diagnostic techniques...

  14. Clinical and Laboratory Findings in Patients With Acute Respiratory Symptoms That Suggest the Necessity of Chest X-ray for Community-Acquired Pneumonia.

    PubMed

    Ebrahimzadeh, Azadeh; Mohammadifard, Mahyar; Naseh, Godratallah; Mirgholami, Alireza

    2015-01-01

    Pneumonia is a common illness in all parts of the world and is considered as a major cause of death among all age groups. Nevertheless, only about 5% of patients referring to their primary care physicians with acute respiratory symptoms will develop pneumonia. This study was performed to derive practical criteria for performing chest radiographs for the evaluation of community-acquired pneumonia (CAP). A total of 420 patients with acute respiratory symptoms and positive findings on chest radiograph were evaluated from December 2008 to December 2009. The subjects were referred to outpatient clinics or emergency departments of Birjand's medical university hospitals, Iran, and were enrolled as positive cases. A checklist was completed for each patient including their demographic information, clinical signs and symptoms (cough, sputum production, dyspnea, chest pain, fever, tachycardia, and tachypnea), abnormal findings in pulmonary auscultation and laboratory findings (erythrocyte sedimentation rate, C-reactive protein levels, and white blood cell count). An equal number of age-matched individuals with acute respiratory symptoms, but insignificant findings on chest radiography, were included as the control group. Finally, the diagnostic values of different findings were compared. The data showed that vital signs and physical examination findings are useful screening parameters for predicting chest radiograph findings in outpatient settings. Therefore, by implementing a prediction rule, we would be able to determine which patients would benefit from a chest X-Ray (sensitivity, 94% and specificity, 57%). This study's findings suggest that requesting chest radiographs might not be necessary in patients with acute respiratory symptoms unless the vital signs and/or physical examination findings are abnormal. Considering the 94% sensitivity of this rule for predicting CAP, a chest radiograph is required for patients with unreliable follow-ups or moderate to high likelihood

  15. What Can Be Learned From a Laboratory Model of Conceptual Change? Descriptive Findings and Methodological Issues

    NASA Astrophysics Data System (ADS)

    Ohlsson, Stellan; Cosejo, David G.

    2014-07-01

    The problem of how people process novel and unexpected information— deep learning (Ohlsson in Deep learning: how the mind overrides experience. Cambridge University Press, New York, 2011)—is central to several fields of research, including creativity, belief revision, and conceptual change. Researchers have not converged on a single theory for conceptual change, nor has any one theory been decisively falsified. One contributing reason is the difficulty of collecting informative data in this field. We propose that the commonly used methodologies of historical analysis, classroom interventions, and developmental studies, although indispensible, can be supplemented with studies of laboratory models of conceptual change. We introduce re- categorization, an experimental paradigm in which learners transition from one definition of a categorical concept to another, incompatible definition of the same concept, a simple form of conceptual change. We describe a re-categorization experiment, report some descriptive findings pertaining to the effects of category complexity, the temporal unfolding of learning, and the nature of the learner's final knowledge state. We end with a brief discussion of ways in which the re-categorization model can be improved.

  16. Multifaceted intervention including education, rounding checklist implementation, cost feedback, and financial incentives reduces inpatient laboratory costs.

    PubMed

    Yarbrough, Peter M; Kukhareva, Polina V; Horton, Devin; Edholm, Karli; Kawamoto, Kensaku

    2016-05-01

    Inappropriate laboratory testing is a contributor to waste in healthcare. To evaluate the impact of a multifaceted laboratory reduction intervention on laboratory costs. A retrospective, controlled, interrupted time series (ITS) study. University of Utah Health Care, a 500-bed academic medical center in Salt Lake City, Utah. All patients 18 years or older admitted to the hospital to a service other than obstetrics, rehabilitation, or psychiatry. Multifaceted quality-improvement initiative in a hospitalist service including education, process change, cost feedback, and financial incentive. Primary outcomes of lab cost per day and per visit. Secondary outcomes of number of basic metabolic panel (BMP), comprehensive metabolic panel (CMP), complete blood count (CBC), and prothrombin time/international normalized ratio tests per day; length of stay (LOS); and 30-day readmissions. A total of 6310 hospitalist patient visits (intervention group) were compared to 25,586 nonhospitalist visits (control group). Among the intervention group, the unadjusted mean cost per day was reduced from $138 before the intervention to $123 after the intervention (P < 0.001), and the unadjusted mean cost per visit decreased from $618 to $558 (P = 0.005). The ITS analysis showed significant reductions in cost per day, cost per visit, and the number of BMP, CMP, and CBC tests per day (P = 0.034, 0.02, <0.001, 0.004, and <0.001). LOS was unchanged and 30-day readmissions decreased in the intervention group. A multifaceted approach to laboratory reduction demonstrated a significant reduction in laboratory cost per day and per visit, as well as common tests per day at a major academic medical center. Journal of Hospital Medicine 2016;11:348-354. © 2016 Society of Hospital Medicine. © 2016 Society of Hospital Medicine.

  17. Comparison of clinical characteristics and laboratory findings of malaria, dengue, and enteric fever in returning travelers: 8-year experience at a referral center in Tokyo, Japan.

    PubMed

    Kutsuna, Satoshi; Hayakawa, Kayoko; Kato, Yasuyuki; Fujiya, Yoshihiro; Mawatari, Momoko; Takeshita, Nozomi; Kanagawa, Shuzo; Ohmagari, Norio

    2015-07-01

    Without specific symptoms, diagnosis of febrile illness in returning travelers is challenging. Dengue, malaria, and enteric fever are common causes of fever in returning travelers and timely and appropriate treatment is important. However, differentiation is difficult without specific diagnostic tests. A retrospective study was conducted at the National Centre for Global Health and Medicine (NCGM) from April 2005 to March 2013. Febrile travelers returning from overseas who were diagnosed with dengue, malaria, or enteric fever were included in this study. Clinical characteristics and laboratory findings were compared for each diagnosis. During the study period, 86 malaria, 85 dengue, and 31 enteric fever cases were identified. The mean age of the study cohort was 33.1 ± 12 years and 134 (66.3%) study participants were male. Asia was the most common area visited by returning travelers with fevers (89% of dengue, 18.6% of malaria, and 100% of enteric fever cases), followed by Africa (1.2% of dengue and 70.9% of malaria cases). Clinical characteristics and laboratory findings were significantly different among each group with each diagnosis. Decision tree models revealed that returning from Africa and CRP levels < 10 mg/L were factors specific for diagnosis of malaria and dengue fever, respectively. Clinical manifestations, simple laboratory test results, and regions of travel are helpful to distinguish between dengue, malaria, and enteric fever in febrile returning travelers with non-specific symptoms.

  18. Anthropometric measures in cardiovascular disease prediction: comparison of laboratory-based versus non-laboratory-based model.

    PubMed

    Dhana, Klodian; Ikram, M Arfan; Hofman, Albert; Franco, Oscar H; Kavousi, Maryam

    2015-03-01

    Body mass index (BMI) has been used to simplify cardiovascular risk prediction models by substituting total cholesterol and high-density lipoprotein cholesterol. In the elderly, the ability of BMI as a predictor of cardiovascular disease (CVD) declines. We aimed to find the most predictive anthropometric measure for CVD risk to construct a non-laboratory-based model and to compare it with the model including laboratory measurements. The study included 2675 women and 1902 men aged 55-79 years from the prospective population-based Rotterdam Study. We used Cox proportional hazard regression analysis to evaluate the association of BMI, waist circumference, waist-to-hip ratio and a body shape index (ABSI) with CVD, including coronary heart disease and stroke. The performance of the laboratory-based and non-laboratory-based models was evaluated by studying the discrimination, calibration, correlation and risk agreement. Among men, ABSI was the most informative measure associated with CVD, therefore ABSI was used to construct the non-laboratory-based model. Discrimination of the non-laboratory-based model was not different than laboratory-based model (c-statistic: 0.680-vs-0.683, p=0.71); both models were well calibrated (15.3% observed CVD risk vs 16.9% and 17.0% predicted CVD risks by the non-laboratory-based and laboratory-based models, respectively) and Spearman rank correlation and the agreement between non-laboratory-based and laboratory-based models were 0.89 and 91.7%, respectively. Among women, none of the anthropometric measures were independently associated with CVD. Among middle-aged and elderly where the ability of BMI to predict CVD declines, the non-laboratory-based model, based on ABSI, could predict CVD risk as accurately as the laboratory-based model among men. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  19. Laboratory for Atmospheres: Philosophy, Organization, Major Activities, and 2001 Highlights

    NASA Technical Reports Server (NTRS)

    Hoegy, Walter R.; Cote, Charles, E.

    2002-01-01

    How can we improve our ability to predict the weather? How is the Earth's climate changing? What can the atmospheres of other planets teach us about our own? The Laboratory for Atmospheres is helping to answer these and other scientific questions. The Laboratory conducts a broad theoretical and experimental research program studying all aspects of the atmospheres of the Earth and other planets, including their structural, dynamical, radiative, and chemical properties. Vigorous research is central to NASA's exploration of the frontiers of knowledge. NASA scientists play a key role in conceiving new space missions, providing mission requirements., and carrying out research to explore the behavior of planetary systems, including, notably, the Earth's. Our Laboratory's scientists also supply outside scientists with technical assistance and scientific data to further investigations not immediately addressed by NASA itself. The Laboratory for Atmospheres is a vital participant in NASA's research program. The Laboratory is part of the Earth Sciences Directorate based at NASA's Goddard Space Flight Center in Greenbelt, Maryland. The Directorate itself comprises the Global Change Data Center; the Earth and Space Data Computing Division; three laboratories: the Laboratory for Atmospheres, the Laboratory for Terrestrial Physics, and the Laboratory for Hydrospheric Processes; and the Goddard Institute for Space Studies (GISS) in New York, New York. In this report, you will find a statement of our philosophy and a description of our role in NASA's mission. You'll also find a broad description of our research and a summary of our scientists' major accomplishments in 2001. The report also presents useful information on human resources, scientific interactions, and outreach activities with the outside community. For your convenience, we have published a version of this report on the Internet. Our Web site includes links to additional information about the Laboratory's Offices and

  20. Human Laboratory Paradigms in Alcohol Research

    PubMed Central

    Plebani, Jennifer G.; Ray, Lara A.; Morean, Meghan E.; Corbin, William R.; Mackillop, James; Amlung, Michael; King, Andrea C.

    2014-01-01

    Human laboratory studies have a long and rich history in the field of alcoholism. Human laboratory studies have allowed for advances in alcohol research in a variety of ways, including elucidating of the neurobehavioral mechanisms of risk, identifying phenotypically distinct sub-types of alcohol users, investigating of candidate genes underlying experimental phenotypes for alcoholism, and testing mechanisms of action of alcoholism pharmacotherapies on clinically-relevant translational phenotypes, such as persons exhibiting positive-like alcohol effects or alcohol craving. Importantly, the field of human laboratory studies in addiction has progressed rapidly over the past decade and has built upon earlier findings of alcohol's neuropharmacological effects to advancing translational research on alcoholism etiology and treatment. To that end, the new generation of human laboratory studies has focused on applying new methodologies, further refining alcoholism phenotypes, and translating these findings to studies of alcoholism genetics, medication development, and pharmacogenetics. The combination of experimental laboratory approaches with recent developments in neuroscience and pharmacology has been particularly fruitful in furthering our understanding of the impact of individual differences in alcoholism risk and in treatment response. This review of the literature focuses on human laboratory studies of subjective intoxication, alcohol craving, anxiety, and behavioral economics. Each section discusses opportunities for phenotype refinement under laboratory conditions, as well as its application to translational science of alcoholism. A summary and recommendations for future research are also provided. PMID:22309888

  1. Vestibular Migraine in Children and Adolescents: Clinical Findings and Laboratory Tests

    PubMed Central

    Langhagen, Thyra; Lehrer, Nicole; Borggraefe, Ingo; Heinen, Florian; Jahn, Klaus

    2015-01-01

    Introduction: Vestibular migraine (VM) is the most common cause of episodic vertigo in children. We summarize the clinical findings and laboratory test results in a cohort of children and adolescents with VM. We discuss the limitations of current classification criteria for dizzy children. Methods: A retrospective chart analysis was performed on 118 children with migraine related vertigo at a tertiary care center. Patients were grouped in the following categories: (1) definite vestibular migraine (dVM); (2) probable vestibular migraine (pVM); (3) suspected vestibular migraine (sVM); (4) benign paroxysmal vertigo (BPV); and (5) migraine with/without aura (oM) plus vertigo/dizziness according to the International Classification of Headache Disorders, 3rd edition (beta version). Results: The mean age of all patients was 12 ± 3 years (range 3–18 years, 70 females). 36 patients (30%) fulfilled criteria for dVM, 33 (28%) for pVM, 34 (29%) for sVM, 7 (6%) for BPV, and 8 (7%) for oM. Somatoform vertigo (SV) co-occurred in 27% of patients. Episodic syndromes were reported in 8%; the family history of migraine was positive in 65%. Mild central ocular motor signs were found in 24% (most frequently horizontal saccadic pursuit). Laboratory tests showed that about 20% had pathological function of the horizontal vestibulo-ocular reflex, and almost 50% had abnormal postural sway patterns. Conclusion: Patients with definite, probable, and suspected VM do not differ in the frequency of ocular motor, vestibular, or postural abnormalities. VM is the best explanation for their symptoms. It is essential to establish diagnostic criteria in clinical studies. In clinical practice, however, the most reasonable diagnosis should be made in order to begin treatment. Such a procedure also minimizes the fear of the parents and children, reduces the need to interrupt leisure time and school activities, and prevents the development of SV. PMID:25674076

  2. Science Laboratory Safety: Findings and Implications for Teacher Education.

    ERIC Educational Resources Information Center

    Swami, Piyush

    1986-01-01

    Summarizes a survey of the condition of high school science laboratories in the greater Cincinnati area (N=36). Reports safety measures undertaken for fire and burn and eye and face protection, waste disposal, storage facilities, and ventilation. Offers suggestions and plans for enriching safety education programs for teachers. (ML)

  3. Pandemic (H1N1) 2009: clinical and laboratory findings of the first fifty cases in Singapore.

    PubMed

    Chan, Monica; Chen, Mark I; Chow, Angela; Lee, Caroline P S; Tan, Adriana S H; Lye, David Chien; Leo, Yee Sin

    2010-04-01

    Since the fi rst imported case on 26 May 2009, pandemic (H1N1) 2009 has spread from travellers and has resulted in sustained community transmission. Singapore began with a strict containment policy where all suspected and confirmed cases of pandemic (H1N1) 2009 were admitted for testing. We describe here the clinical and laboratory characteristics of the fi rst 50 adult cases with confirmed pandemic (H1N1) 2009. A review was conducted of medical notes of adult patients with confirmed pandemic (H1N1) 2009 by polymerase chain reaction assay from combined nasal and throat swabs admitted to the Communicable Disease Centre, Tan Tock Seng Hospital. From 26 May to 18 June 2009, 50 patients with a median age of 27 years old were admitted at a median of 3 days from illness onset. Half were male and all were travellers arriving in Singapore. Non-Singaporean citizens (38%) and other ethnic groups (40%) were over-represented. History of fever was reported in 90% and respiratory symptoms in 92%. Gastrointestinal symptoms were uncommon, present in 4% only. Temperatures on presentation of >or=38.0 degrees C, >or=37.8 degrees C and >or=37.5 degrees C were present in 48%, 56% and 76%, respectively. Only 46% of patients met the United States Centers for Disease Control and Prevention (US CDC) case definition of influenza-like illness (ILI). Clinical and laboratory findings were unremarkable for the majority. All cases were treated with oseltamivir and had uncomplicated recovery. Pandemic (H1N1) 2009 had mild clinical and laboratory findings in immunocompetent patients. Use of the US CDC ILI criteria alone would have detected less than half of confirmed cases.

  4. Software Engineering Laboratory Series: Collected Software Engineering Papers. Volume 15

    NASA Technical Reports Server (NTRS)

    1997-01-01

    The Software Engineering Laboratory (SEL) is an organization sponsored by NASA/GSFC and created to investigate the effectiveness of software engineering technologies when applied to the development of application software. The activities, findings, and recommendations of the SEL are recorded in the Software Engineering Laboratory Series, a continuing series of reports that includes this document.

  5. Software Engineering Laboratory Series: Collected Software Engineering Papers. Volume 14

    NASA Technical Reports Server (NTRS)

    1996-01-01

    The Software Engineering Laboratory (SEL) is an organization sponsored by NASA/GSFC and created to investigate the effectiveness of software engineering technologies when applied to the development of application software. The activities, findings, and recommendations of the SEL are recorded in the Software Engineering Laboratory Series, a continuing series of reports that includes this document.

  6. Software Engineering Laboratory Series: Collected Software Engineering Papers. Volume 13

    NASA Technical Reports Server (NTRS)

    1995-01-01

    The Software Engineering Laboratory (SEL) is an organization sponsored by NASA/GSFC and created to investigate the effectiveness of software engineering technologies when applied to the development of application software. The activities, findings, and recommendations of the SEL are recorded in the Software Engineering Laboratory Series, a continuing series of reports that includes this document.

  7. 20 CFR 220.114 - Evaluation of symptoms, including pain.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... physician or psychologist, and others about the claimant's medical history, diagnosis, prescribed treatment... reasonably be accepted as consistent with the medical signs and laboratory findings), would lead to a... medical history, the medical signs and laboratory findings and statements about how the claimant's...

  8. 20 CFR 220.114 - Evaluation of symptoms, including pain.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... physician or psychologist, and others about the claimant's medical history, diagnosis, prescribed treatment... reasonably be accepted as consistent with the medical signs and laboratory findings), would lead to a... medical history, the medical signs and laboratory findings and statements about how the claimant's...

  9. 20 CFR 220.114 - Evaluation of symptoms, including pain.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... physician or psychologist, and others about the claimant's medical history, diagnosis, prescribed treatment... reasonably be accepted as consistent with the medical signs and laboratory findings), would lead to a... medical history, the medical signs and laboratory findings and statements about how the claimant's...

  10. 20 CFR 220.114 - Evaluation of symptoms, including pain.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... physician or psychologist, and others about the claimant's medical history, diagnosis, prescribed treatment... reasonably be accepted as consistent with the medical signs and laboratory findings), would lead to a... medical history, the medical signs and laboratory findings and statements about how the claimant's...

  11. 20 CFR 220.114 - Evaluation of symptoms, including pain.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... physician or psychologist, and others about the claimant's medical history, diagnosis, prescribed treatment... reasonably be accepted as consistent with the medical signs and laboratory findings), would lead to a... medical history, the medical signs and laboratory findings and statements about how the claimant's...

  12. A multivariate assessment of the effect of the laboratory homework component of a microcomputer-based laboratory for a college freshman physics course

    NASA Astrophysics Data System (ADS)

    Ramlo, Susan E.

    Microcomputer-based laboratories (MBLs) have been defined as software that uses an electronic probe to collect information about a physical system and then converts that information into graphical systems in real-time. Realtime Physics Laboratories (RTP) are an example of laboratories that combine the use of MBLs with collaboration and guided-inquiry. RTP Mechanics Laboratories include both laboratory activities and laboratory homework for the first semester of college freshman physics courses. Prior research has investigated the effectiveness of the RTP laboratories as a package (laboratory activities with laboratory homework). In this study, an experimental-treatment had students complete both the RTP laboratory activity and the associated laboratory homework during the same laboratory period. Observations of this treatment indicated that students primarily consulted the laboratory instructor and referred to their completed laboratory activity while completing the homework in their collaborative groups. In the control-treatment, students completed the laboratory homework outside the laboratory period. Measures of force and motion conceptual understanding included the Force and Motion Conceptual Understanding (FMCE), a 47 multiple-choice question test. Analyses of the FMCE indicated that it is both a reliable and a valid measure of force and motion conceptual understanding. A distinct, five-factor structure for the FMCE post-test answers reflected specific concepts related to force and motion. However, the three FMCE pretest factors were less distinct. Analysis of the experimental-treatment, compared to a control-treatment, included multiple regression analysis with covariates of age, prior physics-classroom experience, and the three FMCE pretest factors. Criterion variables included each of the five post-test factors, the total laboratory homework score, and a group of seven exam questions. The results were all positive, in favor of the experimental

  13. Comparison of clinical characteristics and laboratory findings of malaria, dengue, and enteric fever in returning travelers: 8-year experience at a referral center in Tokyo, Japan.

    PubMed

    Kutsuna, Satoshi; Hayakawa, Kayoko; Kato, Yasuyuki; Fujiya, Yoshihiro; Mawatari, Momoko; Takeshita, Nozomi; Kanagawa, Shuzo; Ohmagari, Norio

    2015-04-01

    Without specific symptoms, diagnosis of febrile illness in returning travelers is challenging. Dengue, malaria, and enteric fever are common causes of fever in returning travelers and timely and appropriate treatment is important. However, differentiation is difficult without specific diagnostic tests. A retrospective study was conducted at the National Centre for Global Health and Medicine (NCGM) from April 2005 to March 2013. Febrile travelers returning from overseas who were diagnosed with dengue, malaria, or enteric fever were included in this study. Clinical characteristics and laboratory findings were compared for each diagnosis. During the study period, 86 malaria, 85 dengue, and 31 enteric fever cases were identified. The mean age of the study cohort was 33.1 ± 12 years and 134 (66.3%) study participants were male. Asia was the most common area visited by returning travelers with fevers (89% of dengue, 18.6% of malaria, and 100% of enteric fever cases), followed by Africa (1.2% of dengue and 70.9% of malaria cases). Clinical characteristics and laboratory findings were significantly different among each group with each diagnosis. Decision tree models revealed that returning from Africa and CRP levels <10 mg/L were factors specific for diagnosis of malaria and dengue fever, respectively. Clinical manifestations, simple laboratory test results, and regions of travel are helpful to distinguish between dengue, malaria, and enteric fever in febrile returning travelers with non-specific symptoms. Copyright © 2014 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  14. National survey on intra-laboratory turnaround time for some most common routine and stat laboratory analyses in 479 laboratories in China.

    PubMed

    Fei, Yang; Zeng, Rong; Wang, Wei; He, Falin; Zhong, Kun; Wang, Zhiguo

    2015-01-01

    To investigate the state of the art of intra-laboratory turnaround time (intra-TAT), provide suggestions and find out whether laboratories accredited by International Organization for Standardization (ISO) 15189 or College of American Pathologists (CAP) will show better performance on intra-TAT than non-accredited ones. 479 Chinese clinical laboratories participating in the external quality assessment programs of chemistry, blood gas, and haematology tests organized by the National Centre for Clinical Laboratories in China were included in our study. General information and the median of intra-TAT of routine and stat tests in last one week were asked in the questionnaires. The response rate of clinical biochemistry, blood gas, and haematology testing were 36% (479/1307), 38% (228/598), and 36% (449/1250), respectively. More than 50% of laboratories indicated that they had set up intra-TAT median goals and almost 60% of laboratories declared they had monitored intra-TAT generally for every analyte they performed. Among all analytes we investigated, the intra-TAT of haematology analytes was shorter than biochemistry while the intra-TAT of blood gas analytes was the shortest. There were significant differences between median intra-TAT on different days of the week for routine tests. However, there were no significant differences in median intra-TAT reported by accredited laboratories and non-accredited laboratories. Many laboratories in China are aware of intra-TAT control and are making effort to reach the target. There is still space for improvement. Accredited laboratories have better status on intra-TAT monitoring and target setting than the non-accredited, but there are no significant differences in median intra-TAT reported by them.

  15. National survey on intra-laboratory turnaround time for some most common routine and stat laboratory analyses in 479 laboratories in China

    PubMed Central

    Fei, Yang; Zeng, Rong; Wang, Wei; He, Falin; Zhong, Kun

    2015-01-01

    Introduction To investigate the state of the art of intra-laboratory turnaround time (intra-TAT), provide suggestions and find out whether laboratories accredited by International Organization for Standardization (ISO) 15189 or College of American Pathologists (CAP) will show better performance on intra-TAT than non-accredited ones. Materials and methods 479 Chinese clinical laboratories participating in the external quality assessment programs of chemistry, blood gas, and haematology tests organized by the National Centre for Clinical Laboratories in China were included in our study. General information and the median of intra-TAT of routine and stat tests in last one week were asked in the questionnaires. Results The response rate of clinical biochemistry, blood gas, and haematology testing were 36% (479 / 1307), 38% (228 / 598), and 36% (449 / 1250), respectively. More than 50% of laboratories indicated that they had set up intra-TAT median goals and almost 60% of laboratories declared they had monitored intra-TAT generally for every analyte they performed. Among all analytes we investigated, the intra-TAT of haematology analytes was shorter than biochemistry while the intra-TAT of blood gas analytes was the shortest. There were significant differences between median intra-TAT on different days of the week for routine tests. However, there were no significant differences in median intra-TAT reported by accredited laboratories and non-accredited laboratories. Conclusions Many laboratories in China are aware of intra-TAT control and are making effort to reach the target. There is still space for improvement. Accredited laboratories have better status on intra-TAT monitoring and target setting than the non-accredited, but there are no significant differences in median intra-TAT reported by them. PMID:26110033

  16. Fracture induced electromagnetic emissions: extending laboratory findings by observations at the geophysical scale

    NASA Astrophysics Data System (ADS)

    Potirakis, Stelios M.; Contoyiannis, Yiannis; Kopanas, John; Kalimeris, Anastasios; Antonopoulos, George; Peratzakis, Athanasios; Eftaxias, Konstantinos; Nomicos, Constantinos

    2014-05-01

    Under natural conditions, it is practically impossible to install an experimental network on the geophysical scale using the same instrumentations as in laboratory experiments for understanding, through the states of stress and strain and their time variation, the laws that govern the friction during the last stages of EQ generation, or to monitor (much less to control) the principal characteristics of a fracture process. Fracture-induced electromagnetic emissions (EME) in a wide range of frequency bands are sensitive to the micro-structural chances. Thus, their study constitutes a nondestructive method for the monitoring of the evolution of damage process at the laboratory scale. It has been suggested that fracture induced MHz-kHz electromagnetic (EM) emissions, which emerge from a few days up to a few hours before the main seismic shock occurrence permit a real time monitoring of the damage process during the last stages of earthquake preparation, as it happens at the laboratory scale. Since the EME are produced both in the case of the laboratory scale fracture and the EQ preparation process (geophysical scale fracture) they should present similar characteristics in these two scales. Therefore, both the laboratory experimenting scientists and the experimental scientists studying the pre-earthquake EME could benefit from each- other's results. Importantly, it is noted that when studying the fracture process by means of laboratory experiments, the fault growth process normally occurs violently in a fraction of a second. However, a major difference between the laboratory and natural processes is the order-of-magnitude differences in scale (in space and time), allowing the possibility of experimental observation at the geophysical scale for a range of physical processes which are not observable at the laboratory scale. Therefore, the study of fracture-induced EME is expected to reveal more information, especially for the last stages of the fracture process, when it

  17. Picatinny Arsenal 3000 Area Laboratory Complex Energy Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Daryl R.; Goddard, James K.

    2010-05-01

    In response to a request by Picatinny Arsenal, the Pacific Northwest National Laboratory (PNNL) was asked by the Army to conduct an energy audit of the Arsenal’s 3000 Area Laboratory Complex. The objective of the audit was to identify life-cycle cost-effective measures that the Arsenal could implement to reduce energy costs. A “walk-through” audit of the facilities was conducted on December 7-8, 2009. Findings and recommendations are included in this document.

  18. Burning mouth syndrome: Evaluation of clinical and laboratory findings.

    PubMed

    Halac, Gulistan; Tekturk, Pinar; Eroglu, Saliha; Cikrikcioglu, Mehmet Ali; Cimendur, Ozlem; Kilic, Elif; Asil, Talip

    2016-07-30

    Burning mouth syndrome is a chronic and persistent painful condition characterized by burning sensation in the oral mucosa. We investigated the etiological factors of patients presented with the history of burning in the mouth who admitted our outpatient clinics over the 8-years period and who had no underlying identifiable local factors. We also tried to determine their demographic and clinical characteristics. Our aim was to investigate the association between burning mouth and psychiatric disorders such as depression and anxiety, chronic diseases like diabetes mellitus (DM) and other laboratory studies in patients complaining of solely burning in the mouth. The study included patients with the history of burning in mouth who presented in our outpatient clinic between 2005 and 2012. They were evaluated by a neurologist, a psychiatrist, an internist, and a dentist. Complete blood counts, biochemical analysis and cranial magnetic resonance imaging (MRI) were performed for all patients. A total of 26 (22 (84%) females, 4 (15%) males; mean age 55.9 years) patients were enrolled in this study. Five (19.2%) of the patients had depression, 2 (7.7%) had anxiety disorder, 2 (7.7%) had diabetes mellitus, 8 (30%) had B12 vitamin deficiency, 3 (11.5%) had decreased ferritin levels in blood, and 1 (3.8%) had folic acid deficiency. Cranial MRI of all patients were normal. Nine patients (34.6%) had no etiological causes. A multidisciplinary approach in the management of burning mouth and establishment of common criteria for the diagnosis would provide insight into the underlying pathophysiological mechanism.

  19. Software Engineering Laboratory Series: Proceedings of the Twentieth Annual Software Engineering Workshop

    NASA Technical Reports Server (NTRS)

    1995-01-01

    The Software Engineering Laboratory (SEL) is an organization sponsored by NASA/GSFC and created to investigate the effectiveness of software engineering technologies when applied to the development of application software. The activities, findings, and recommendations of the SEL are recorded in the Software Engineering Laboratory Series, a continuing series of reports that includes this document.

  20. Staff and students' perceptions and experiences of teaching and assessment in Clinical Skills Laboratories: interview findings from a multiple case study.

    PubMed

    Houghton, Catherine E; Casey, Dympna; Shaw, David; Murphy, Kathy

    2012-08-01

    The Clinical Skills Laboratory has become an essential structure in nurse education and several benefits of its use have been identified. However, the literature identifies the need to examine the transferability of skills learned there into the reality of practice. This research explored the role of the Clinical Skills Laboratory in preparing nursing students for the real world of practice. This paper focuses specifically on the perceptions of the teaching and assessment strategies employed there. Qualitative multiple case study design. Five case study sites. Interviewees (n=58) included academic staff, clinical staff and nursing students. Semi-structured interviews. The Clinical Skills Laboratory can provide a pathway to practice and its authenticity is significant. Teaching strategies need to incorporate communication as well as psychomotor skills. Including audio-visual recording into assessment strategies is beneficial. Effective relationships between education institutions and clinical settings are needed to enhance the transferability of the skills learned. The Clinical Skills Laboratory should provide an authentic learning environment, with the appropriate use of teaching strategies. It is crucial that effective links between educators and clinical staff are established and maintained. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. Chest CT findings of toxocariasis: correlation with laboratory results.

    PubMed

    Hur, J H; Lee, I J; Kim, J-H; Kim, D-G; Hwang, H J; Koh, S H; Lee, K

    2014-06-01

    To assess the relationship between chest computed tomography (CT) findings of patients with toxocariasis and levels of serological markers. A total of 38 cases of patients diagnosed with toxocariasis by enzyme-linked immunosorbent assay (ELISA), CT, and serological markers were retrospectively reviewed. The presence of nodule with or without ground-glass opacity (GGO) halo, consolidation, focal GGO, pleural effusion, and lymphadenopathy at chest CT were evaluated. Statistical analysis was performed with the Fisher's exact test. The most common chest CT findings were nodule (n = 12, 31.6%) and focal GGO (n = 12, 31.6%). In patients with normal eosinophil levels, focal GGO (n = 9, 37.5%) was the most common finding. In contrast, nodule with a GGO halo (n = 7, 50%) was the most common finding in the eosinophilia group. Nodule with a GGO halo was more common in the eosinophilia group, with a statistically significant difference (p = 0.017). Nodule was more common in the eosinophilia group, and focal GGO was more common in the normal eosinophil group. The most common chest CT findings in toxocariasis were nodule with or without GGO halo, and focal GGO. In the eosinophilia group, nodule with a GGO halo was significantly more frequent. Other CT findings did not show a statistically significant relationship with serological markers. Copyright © 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  2. Solid-State NMR Spectroscopy for the Physical Chemistry Laboratory

    ERIC Educational Resources Information Center

    Kinnun, Jacob J.; Leftin, Avigdor; Brown, Michael F.

    2013-01-01

    Solid-state nuclear magnetic resonance (NMR) spectroscopy finds growing application to inorganic and organic materials, biological samples, polymers, proteins, and cellular membranes. However, this technique is often neither included in laboratory curricula nor typically covered in undergraduate courses. On the other hand, spectroscopy and…

  3. Electrocardiograhic findings resulting in inappropriate cardiac catheterization laboratory activation for ST-segment elevation myocardial infarction

    PubMed Central

    Shamim, Shariq; McCrary, Justin; Wayne, Lori; Gratton, Matthew

    2014-01-01

    Background Prompt reperfusion has been shown to improve outcomes in patients with acute ST-segment elevation myocardial infarction (STEMI) with a goal of culprit vessel patency in <90 minutes. This requires a coordinated approach between the emergency medical services (EMS), emergency department (ED) and interventional cardiology. The urgency of this process can contribute to inappropriate cardiac catheterization laboratory (CCL) activations. Objectives One of the major determinants of inappropriate activations has been misinterpretation of the electrocardiogram (ECG) in the patient with acute chest pain. Methods We report the ECG findings for all CCL activations over an 18-month period after the inception of a STEMI program at our institution. Results There were a total of 139 activations with 77 having a STEMI diagnosis confirmed and 62 activations where there was no STEMI. The inappropriate activations resulted from a combination of atypical symptoms and misinterpretation of the ECG (45% due to anterior ST-segment elevation) on patient presentation. The electrocardiographic abnormalities were particularly problematic in African-Americans with left ventricular hypertrophy. Conclusions In this single-center, prospective observational study, nearly half of the inappropriate STEMI activations were due to the misinterpretation of anterior ST-segment elevation and this finding was commonly seen in African-Americans with left ventricular hypertrophy. PMID:25009790

  4. Software Engineering Laboratory Series: Proceedings of the Twenty-First Annual Software Engineering Workshop

    NASA Technical Reports Server (NTRS)

    1996-01-01

    The Software Engineering Laboratory (SEL) is an organization sponsored by NASA/GSFC and created to investigate the effectiveness of software engineering technologies when applied to the development of application software. The activities, findings, and recommendations of the SEL are recorded in the Software Engineering Laboratory Series, a continuing series of reports that includes this document.

  5. Software Engineering Laboratory Series: Proceedings of the Twenty-Second Annual Software Engineering Workshop

    NASA Technical Reports Server (NTRS)

    1997-01-01

    The Software Engineering Laboratory (SEL) is an organization sponsored by NASA/GSFC and created to investigate the effectiveness of software engineering technologies when applied to the development of application software. The activities, findings, and recommendations of the SEL are recorded in the Software Engineering Laboratory Series, a continuing series of reports that includes this document.

  6. The Language Laboratory.

    ERIC Educational Resources Information Center

    Hughes, John P.

    Concepts pertaining to the language laboratory are clarified for the layman unfamiliar with recent educational developments in foreign language instruction. These include discussion of: (1) language laboratory components and functions, (2) techniques used in the laboratory, (3) new linguistic methods, (4) laboratory exercises, (5) traditional…

  7. [Evaluation of the epidemiological, clinical and laboratory findings in continuous ambulatory peritoneal dialysis related peritonitis attacks].

    PubMed

    Bulut, Cemal; Oztürk, Reyhan; Yilmaz, Gül Ruhsar; Parpucu, Hülya; Irmak, Hasan; Kinikli, Sami; Duranay, Murat; Demiröz, Ali Pekcan

    2008-04-01

    The aims of this study were to assess epidemiological features, clinical outcomes, laboratory findings, causative organisms and treatment approach for continuous ambulatory peritoneal dialysis (CAPD) -related peritonitis cases. A total of 50 patients (35 male, 15 female; age range: 18-83 years, mean age: 49 +/-17 years) with CAPD related peritonitis treated in Infectious Diseases and Clinical Microbiology Department of Ankara Training and Research Hospital between February-July 2006 were enrolled into this study. Demographic characteristics, symptoms, physical examination findings and laboratory parameters of patients were recorded and evaluated at the baseline, 48 hours and at the end of treatment. Fifty six peritonitis episodes occurred during the study period, and overall incidence of peritonitis was calculated as 1.6 episodes/patient-year. The most common presenting symptoms were cloudiness of the peritoneal dialysis fluid (100%), abdominal pain (98%), nausea (74%) and vomiting (54%). Abdominal tenderness and rebaund (100%) were the most common physical examination findings. Increased levels of C-reactive protein, erythrocyte sedimentation rate and procalcitonin were detected in 88%, 94% and 42% of the patients, respectively. The mean white blood cell count of peritoneal dialysate fluids was 905/mm3 (170-17900/mm3) in 56 episodes. In direct microscopic examination of peritoneal fluid samples with Gram stain, positivity was detected in 10 (18%) of the attacks, in which eight yielded gram-positive cocci and two gram-negative bacilli. The rate of culture positivity was 74% in the peritonitis episodes, and no microorganism was isolated from the cultures of 26% of the episodes. The most frequently isolated microorganisms were coagulase-positive staphylococci, followed by Staphylococcus aureus (n:4) and E. coli (n:4) with the rates of 7% of each, Enterococcus spp. (n:3), Klebsiella spp. (n:3) and Pseudomonas spp. (n:3) with the rates of 5% of each, and Streptococcus

  8. Differences between clinical and laboratory findings in patients with recent diagnosis of SLE according to the positivity of anti-dsDNA by the Crithidia luciliae method.

    PubMed

    Sarbu, M I; Salman-Monte, T C; Rubio Muñoz, P; Lisbona, M P; Almirall Bernabé, M; Carbonell, J

    2015-10-01

    Of all anti-dsDNA antibody detection methods, the Crithidia luciliae immunofluorescence test (CLIF) is considered to have the highest specificity for systemic lupus erythematosus (SLE). The objective of this report is to evaluate whether the presence of anti-dsDNA antibodies detected by the CLIF method is associated with a specific clinical phenotype in recently diagnosed SLE. This retrospective cross-sectional study included all patients with newly diagnosed SLE between 1990 and 2011 and followed up in our institution. Demographic, clinical and laboratory findings were assessed. Correlations between positivity of anti-dsDNA by the CLIF method, clinical and laboratory data were analyzed. A total of 104 patients were included in the analysis. Patients who were positive for anti-dsDNA by the CLIF method at the time of diagnosis had (statistically) significantly higher titers of anti-dsDNA by the ELISA method, antinuclear (ANA) and anticardiolipin antibodies, lymphopenia and complement consumption compared with the other two groups. Also they presented significantly more musculoskeletal symptoms at baseline. The presence of anti-dsDNA by the CLIF method in newly diagnosed SLE was associated with certain markers of increased disease activity. Its use could be a useful biomarker for a specific clinical phenotype suggestive of a more severe involvement at the time of the diagnosis. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  9. Epidemiological Characteristics and Laboratory Findings of Zika Virus Cases in New York City, January 1, 2016-June 30, 2017.

    PubMed

    McGibbon, Emily; Moy, Morgan; Vora, Neil M; Dupuis, Alan; Fine, Annie; Kulas, Karen; Limberger, Ronald; Liu, Dakai; Rakeman, Jennifer; St George, Kirsten; Slavinski, Sally

    2018-05-09

    An outbreak of Zika virus (ZIKV) began in May 2015 in Brazil and rapidly spread throughout the Americas; New York City (NYC) has a diverse population with ∼1.8 million residents who were born in ZIKV-affected areas. Before July 24, 2017, the Centers for Disease Control and Prevention (CDC) ZIKV testing recommendations included nucleic acid amplification-based tests for serum and urine specimens collected ≤14 days of illness onset or last potential exposure, and ZIKV immunoglobulin M (IgM) assay when ZIKV RNA is not detected or for specimens collected within 2-12 weeks of illness onset or last potential exposure, followed by a plaque reduction neutralization test (PRNT). However, the New York public health laboratories and commercial laboratories tested specimens collected beyond these time frames. We analyzed 1080 noncongenital ZIKV cases in NYC residents who met the Council for State and Territorial Epidemiologist's ZIKV case definitions. Among cases, 98% were travel associated, 1% were sexually transmitted, and 1% had unknown exposures; 412 (38%) cases were pregnant women. Of 672 patients with ZIKV RNA detected in serum or urine specimens, 48 (7%) tested positive >14 days after either symptom onset or last potential exposure date (range 15-99 days). Of 390 patients diagnosed based on serology alone (i.e., not tested or not detectable for ZIKV RNA), 60 (15%) had a positive ZIKV IgM and PRNT >12 weeks after symptom onset or last potential exposure date (range 85-273 days). Our findings correspond with CDC's updated guidance to test symptomatic pregnant women up to 12 weeks past onset of symptoms. ZIKV IgM antibody testing may also be warranted for pregnant women regardless of symptoms if their exposure occurred during their pregnancy or periconception period. Providers should understand the scope of diagnostic testing and its limitations to appropriately counsel patients, especially pregnant women.

  10. 40 CFR 262.105 - What must be included in the laboratory environmental management plan?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... management of laboratory wastes and from the reuse, recycling or disposal of such materials outside the... for the purpose of supporting continual improvement of the Environmental Management Plan. (iii...

  11. 40 CFR 262.105 - What must be included in the laboratory environmental management plan?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... management of laboratory wastes and from the reuse, recycling or disposal of such materials outside the... for the purpose of supporting continual improvement of the Environmental Management Plan. (iii...

  12. 40 CFR 262.105 - What must be included in the laboratory environmental management plan?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... management of laboratory wastes and from the reuse, recycling or disposal of such materials outside the... for the purpose of supporting continual improvement of the Environmental Management Plan. (iii...

  13. 40 CFR 262.105 - What must be included in the laboratory environmental management plan?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... management of laboratory wastes and from the reuse, recycling or disposal of such materials outside the... for the purpose of supporting continual improvement of the Environmental Management Plan. (iii...

  14. FUNDAMENTALS LEARNING LABORATORIES IN INDUSTRIAL EDUCATION CENTERS, TECHNICAL INSTITUTES AND COMMUNITY COLLEGES IN NORTH CAROLINA.

    ERIC Educational Resources Information Center

    MARTIN, WALTER TRAVIS, JR.

    IN 1964, NORTH CAROLINA ESTABLISHED A SYSTEM OF "FUNDAMENTALS LEARNING LABORATORIES" WHERE ADULTS MIGHT OBTAIN PROGRAMED SELF-INSTRUCTION AT MINIMAL COST (A $2.00 REGISTRATION FEE). IN A DESCRIPTIVE STUDY OF THE 17 LABORATORIES OPERATING IN 1965, DATA WERE GATHERED BY QUESTIONNAIRES AND INTERVIEWS. FINDINGS INCLUDED THE FOLLOWING-- (1)…

  15. [How to Interpret and Use Routine Laboratory Data--Our Methods to Interpret Routine Laboratory Data--Chairmen's Introductory Remarks].

    PubMed

    Honda, Takayuki; Tozuka, Minoru

    2015-09-01

    In the reversed clinicopathological conference (R-CPC), three specialists in laboratory medicine interpreted routine laboratory data independently in order to understand the detailed state of a patient. R-CPC is an educational method to use laboratory data appropriately, and it is also important to select differential diagnoses in a process of clinical reasoning in addition to the present illness and physical examination. Routine laboratory tests can be performed repeatedly at a relatively low cost, and their time-series analysis can be performed. Interpretation of routine laboratory data is almost the same as taking physical findings. General findings are initially checked and then the state of each organ is examined. Although routine laboratory tests cost little, we can gain much more information from them about the patient than physical examinations.

  16. Laboratory studies, analysis, and interpretation of the spectra of hydrocarbons present in planetary atmospheres including cyanoacetylene, acetylene, propane, and ethane

    NASA Technical Reports Server (NTRS)

    Blass, William E.; Daunt, Stephen J.; Peters, Antoni V.; Weber, Mark C.

    1990-01-01

    Combining broadband Fourier transform spectrometers (FTS) from the McMath facility at NSO and from NRC in Ottawa and narrow band TDL data from the laboratories with computational physics techniques has produced a broad range of results for the study of planetary atmospheres. Motivation for the effort flows from the Voyager/IRIS observations and the needs of Voyager analysis for laboratory results. In addition, anticipation of the Cassini mission adds incentive to pursue studies of observed and potentially observable constituents of planetary atmospheres. Current studies include cyanoacetylene, acetylene, propane, and ethane. Particular attention is devoted to cyanoacetylen (H3CN) which is observed in the atmosphere of Titan. The results of a high resolution infrared laboratory study of the line positions of the 663, 449, and 22.5/cm fundamental bands are presented. Line position, reproducible to better than 5 MHz for the first two bands, are available for infrared astrophysical searches. Intensity and broadening studies are in progress. Acetylene is a nearly ubiquitous atmospheric constituent of the outer planets and Titan due to the nature of methane photochemistry. Results of ambient temperature absolute intensity measurements are presented for the fundamental and two two-quantum hotband in the 730/cm region. Low temperature hotband intensity and linewidth measurements are planned.

  17. Toward a Mouse Neuroethology in the Laboratory Environment

    PubMed Central

    Hellier, Jennifer L.; Ly, Xuan; Koka, Kanthaiah; Tollin, Daniel J.; Restrepo, Diego

    2010-01-01

    In this report we demonstrate that differences in cage type brought unexpected effects on aggressive behavior and neuroanatomical features of the mouse olfactory bulb. A careful characterization of two cage types, including a comparison of the auditory and temperature environments, coupled with a demonstration that naris occlusion abolishes the neuroanatomical changes, lead us to conclude that a likely important factor mediating the phenotypic changes we find is the olfactory environment of the two cages. We infer that seemingly innocuous changes in cage environment can affect sensory input relevant to mice and elicit profound effects on neural output. Study of the neural mechanisms underlying animal behavior in the laboratory environment should be broadened to include neuroethological approaches to examine how the laboratory environment (beyond animal well-being and enrichment) influences neural systems and behavior. PMID:20613876

  18. Finding Little Albert: A Journey to John B. Watson's Infant Laboratory

    ERIC Educational Resources Information Center

    Beck, Hall P.; Levinson, Sharman; Irons, Gary

    2009-01-01

    In 1920, John Watson and Rosalie Rayner claimed to have conditioned a baby boy, Albert, to fear a laboratory rat. In subsequent tests, they reported that the child's fear generalized to other furry objects. After the last testing session, Albert disappeared, creating one of the greatest mysteries in the history of psychology. This article…

  19. Laboratory-produced ball lightning

    NASA Astrophysics Data System (ADS)

    Golka, Robert K., Jr.

    1994-05-01

    For 25 years I have actively been searching for the true nature of ball lightning and attempting to reproduce it at will in the laboratory. As one might expect, many unidentified lights in the atmosphere have been called ball lightning, including Texas Maffa lights (automobile headlights), flying saucers (UFOs), swamp gas in Ann Arbor, Michigan, etc. For 15 years I thought ball lightning was strictly a high-voltage phenomenon. It was not until 1984 when I was short-circuiting the electrical output of a diesel electric railroad locomotive that I realized that the phenomenon was related more to a high current. Although I am hoping for some other types of ball lightning to emerge such as strictly electrostatic-electromagnetic manifestations, I have been unlucky in finding laboratory provable evidence. Cavity-formed plasmodes can be made by putting a 2-inch burning candle in a home kitchen microwave oven. The plasmodes float around for as long as the microwave energy is present.

  20. Bioactive contaminants leach from disposable laboratory plasticware.

    PubMed

    McDonald, G Reid; Hudson, Alan L; Dunn, Susan M J; You, Haitao; Baker, Glen B; Whittal, Randy M; Martin, Jonathan W; Jha, Amitabh; Edmondson, Dale E; Holt, Andrew

    2008-11-07

    Disposable plasticware such as test tubes, pipette tips, and multiwell assay or culture plates are used routinely in most biological research laboratories. Manufacturing of plastics requires the inclusion of numerous chemicals to enhance stability, durability, and performance. Some lubricating (slip) agents, exemplified by oleamide, also occur endogenously in humans and are biologically active, and cationic biocides are included to prevent bacterial colonization of the plastic surface. We demonstrate that these manufacturing agents leach from laboratory plasticware into a standard aqueous buffer, dimethyl sulfoxide, and methanol and can have profound effects on proteins and thus on results from bioassays of protein function. These findings have far-reaching implications for the use of disposable plasticware in biological research.

  1. Salaries and compensation practices in public health, environmental, and agricultural laboratories: findings from a 2010 national survey.

    PubMed

    DeBoy, John M; Boulton, Matthew L; Carpenter, David F

    2013-01-01

    The public health, environmental, and agricultural laboratory (PHEAL) workforce is a key component of the public health infrastructure. The national laboratory workforce faces an ongoing challenge of recruitment and retention of workers often related to pay and other compensation issues. To collect information on laboratory salaries and laboratory compensation practices using a national compensation survey targeting the PHEAL workforce. Seventy-three of 109 (67%) PHEAL directors in the 50 states and District of Columbia collectively employ 3723/4830 (77%) PHEAL employees in the United States. A standardized survey was developed and administered in 2010. Compensation data were compiled by job classification, geographic region, laboratory gross operating budget size, laboratory staff size, and laboratory type. Laboratory staff size ranged from 3 to 327 individuals (mean = 74 and median = 51). Median base salaries were lowest in the Southwest and South and highest in the Mountain and Pacific regions. Mean and median laboratory gross operating budgets for all participating PHEALs were $8 609 238 and $5 671 500, respectively. Extra cash compensation, used by 8 of 60 (13.3%) PHEALs, was more likely to go to a scientist-manager or scientist-supervisor. In 2010, a standardized national compensation survey of technical and scientific public health employees working in 73 PHEALs was effective in collecting previously unavailable data about laboratory salaries, laboratory budgets, and payroll practices. Laboratory salaries varied by geographic region and there was an uneven distribution of extra cash compensation among job classifications. The compensation data collected may be useful in characterizing and improving laboratory salary structures and practices to better support workforce recruitment and retention.

  2. Ophthalmologic Findings in Patients with Neuro-metabolic Disorders.

    PubMed

    Jafari, Narjes; Golnik, Karl; Shahriari, Mansoor; Karimzadeh, Parvaneh; Jabbehdari, Sayena

    2018-01-01

    We aimed to present the ophthalmic manifestations of neuro-metabolic disorders. Patients who were diagnosed with neuro-metabolic disorders in the Neurology Department of Mofid Pediatric Hospital in Tehran, Iran, between 2004 and 2014 were included in this study. Disorders were confirmed using clinical findings, neuroimaging, laboratory data, and genomic analyses. All enrolled patients were assessed for ophthalmological abnormalities. A total of 213 patients with 34 different neuro-metabolic disorders were included. Ophthalmological abnormalities were observed in 33.5% of patients. Abnormal findings in the anterior segment included Kayser-Fleischer rings, congenital or secondary cataracts, and lens dislocation into the anterior chamber. Posterior segment (i.e., retina, vitreous body, and optic nerve) evaluation revealed retinitis pigmentosa, cherry-red spots, and optic atrophy. In addition, strabismus, nystagmus, and lack of fixation were noted during external examination. Ophthalmological examination and assessment is essential in patients that may exhibit neuro-metabolic disorders.

  3. Laboratory Equipment Criteria.

    ERIC Educational Resources Information Center

    State Univ. Construction Fund, Albany, NY.

    Requirements for planning, designing, constructing and installing laboratory furniture are given in conjunction with establishing facility criteria for housing laboratory equipment. Furniture and equipment described include--(1) center tables, (2) reagent racks, (3) laboratory benches and their mechanical fixtures, (4) sink and work counters, (5)…

  4. Laboratory Building

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Herrera, Joshua M.

    2015-03-01

    This report is an analysis of the means of egress and life safety requirements for the laboratory building. The building is located at Sandia National Laboratories (SNL) in Albuquerque, NM. The report includes a prescriptive-based analysis as well as a performance-based analysis. Following the analysis are appendices which contain maps of the laboratory building used throughout the analysis. The top of all the maps is assumed to be north.

  5. How Should Students Learn in the School Science Laboratory? The Benefits of Cooperative Learning

    NASA Astrophysics Data System (ADS)

    Raviv, Ayala; Cohen, Sarit; Aflalo, Ester

    2017-07-01

    Despite the inherent potential of cooperative learning, there has been very little research into its effectiveness in middle school laboratory classes. This study focuses on an empirical comparison between cooperative learning and individual learning in the school science laboratory, evaluating the quality of learning and the students' attitudes. The research included 67 seventh-grade students who undertook four laboratory experiments on the subject of "volume measuring skills." Each student engaged both in individual and cooperative learning in the laboratory, and the students wrote individual or group reports, accordingly. A total of 133 experiment reports were evaluated, 108 of which also underwent textual analysis. The findings show that the group reports were superior, both in terms of understanding the concept of "volume" and in terms of acquiring skills for measuring volume. The students' attitudes results were statistically significant and demonstrated that they preferred cooperative learning in the laboratory. These findings demonstrate that science teachers should be encouraged to implement cooperative learning in the laboratory. This will enable them to improve the quality and efficiency of laboratory learning while using a smaller number of experimental kits. Saving these expenditures, together with the possibility to teach a larger number of students simultaneously in the laboratory, will enable greater exposure to learning in the school science laboratory.

  6. 21 CFR 200.10 - Contract facilities (including consulting laboratories) utilized as extramural facilities by...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Cosmetic Act specifically authorizes inspection of consulting laboratories as well as any factory... Federal Food, Drug, and Cosmetic Act. The Food and Drug Administration's position is that by the... Administration does not consider results of validation studies of analytical and assay methods and control...

  7. 21 CFR 200.10 - Contract facilities (including consulting laboratories) utilized as extramural facilities by...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Cosmetic Act specifically authorizes inspection of consulting laboratories as well as any factory... Federal Food, Drug, and Cosmetic Act. The Food and Drug Administration's position is that by the... Administration does not consider results of validation studies of analytical and assay methods and control...

  8. 21 CFR 200.10 - Contract facilities (including consulting laboratories) utilized as extramural facilities by...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Cosmetic Act specifically authorizes inspection of consulting laboratories as well as any factory... Federal Food, Drug, and Cosmetic Act. The Food and Drug Administration's position is that by the... Administration does not consider results of validation studies of analytical and assay methods and control...

  9. 21 CFR 200.10 - Contract facilities (including consulting laboratories) utilized as extramural facilities by...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Cosmetic Act specifically authorizes inspection of consulting laboratories as well as any factory... Federal Food, Drug, and Cosmetic Act. The Food and Drug Administration's position is that by the... Administration does not consider results of validation studies of analytical and assay methods and control...

  10. Laboratory Information Systems.

    PubMed

    Henricks, Walter H

    2015-06-01

    Laboratory information systems (LISs) supply mission-critical capabilities for the vast array of information-processing needs of modern laboratories. LIS architectures include mainframe, client-server, and thin client configurations. The LIS database software manages a laboratory's data. LIS dictionaries are database tables that a laboratory uses to tailor an LIS to the unique needs of that laboratory. Anatomic pathology LIS (APLIS) functions play key roles throughout the pathology workflow, and laboratories rely on LIS management reports to monitor operations. This article describes the structure and functions of APLISs, with emphasis on their roles in laboratory operations and their relevance to pathologists. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Laboratory Safety is Everyone's Responsibility.

    ERIC Educational Resources Information Center

    Brubaker, Inara M.; And Others

    1981-01-01

    Outlines a survey of laboratory practices and policies for employee protection from exposure to chemicals. Findings support the argument that academic, industrial, and other research laboratories are different from the manufacturing environment and should have a different toxic chemical policy and standards. (Author/SK)

  12. The total laboratory solution: a new laboratory E-business model based on a vertical laboratory meta-network.

    PubMed

    Friedman, B A

    2001-08-01

    Major forces are now reshaping all businesses on a global basis, including the healthcare and clinical laboratory industries. One of the major forces at work is information technology (IT), which now provides the opportunity to create a new economic and business model for the clinical laboratory industry based on the creation of an integrated vertical meta-network, referred to here as the "total laboratory solution" (TLS). Participants at the most basic level of such a network would include a hospital-based laboratory, a reference laboratory, a laboratory information system/application service provider/laboratory portal vendor, an in vitro diagnostic manufacturer, and a pharmaceutical/biotechnology manufacturer. It is suggested that each of these participants would add value to the network primarily in its area of core competency. Subvariants of such a network have evolved over recent years, but a TLS comprising all or most of these participants does not exist at this time. Although the TLS, enabled by IT and closely akin to the various e-businesses that are now taking shape, offers many advantages from a theoretical perspective over the current laboratory business model, its success will depend largely on (a) market forces, (b) how the collaborative networks are organized and managed, and (c) whether the network can offer healthcare organizations higher quality testing services at lower cost. If the concept is successful, new demands will be placed on hospital-based laboratory professionals to shift the range of professional services that they offer toward clinical consulting, integration of laboratory information from multiple sources, and laboratory information management. These information management and integration tasks can only increase in complexity in the future as new genomic and proteomics testing modalities are developed and come on-line in clinical laboratories.

  13. Findings from the Supersonic Qualification Program of the Mars Science Laboratory Parachute System

    NASA Technical Reports Server (NTRS)

    Sengupta, Anita; Steltzner, Adam; Witkowski, Allen; Candler, Graham; Pantano, Carlos

    2009-01-01

    supersonic wind tunnel testing of a rigid DGB parachute with entry-vehicle to validate two high fidelity computational fluid dynamics (CFD) tools. The computer codes utilized Large Eddy Simulation and Detached Eddy Simulation numerical approaches to accurately capture the turbulent wake of the entry vehicle and its coupling to the parachute bow-shock. The second phase was the development of fluid structure interaction (FSI) computational tools to predict parachute response to the supersonic flow field. The FSI development included the integration of the CFD from the first phase with a finite element structural model of the parachute membrane and cable elements. In this phase, a 4% of full-scale supersonic flexible parachute test program was conducted to provide validation data to the FSI code and an empirical dataset of the MSL parachute in a flight-like environment. The final phase is FSI simulations of the full-scale MSL parachute in a Mars type deployment. Findings from this program will be presented in terms of code development and validation, empirical findings from the supersonic testing, and drag performance during supersonic operation.

  14. Present status and perspective of laboratory hematology in Japan: On the standardization of blood cell morphology including myelodysplasia: On behalf of the Japanese Society for Laboratory Hematology.

    PubMed

    Tohyama, K

    2018-05-01

    The Japanese Society for Laboratory Hematology (JSLH) was launched in 2000 and has been developed by a mutual collaboration of hematologists, medical technologists, and the companies involved in hematological laboratory testing. The aim of JSLH is the progress and development of laboratory hematology by academic conferences, periodic publication of academic journal, training and education (in the meeting, the journal, or the website), promotion of the standardization of laboratory hematology, and certification of the laboratory hematology specialists. Among 3 specialized committees organized for the standardization of laboratory hematology, the standardization committee on blood cell morphology has been dealing with the various projects on peripheral/bone marrow blood cells and normal/abnormal morphology. Another independent organization, the Japanese National Research Group on idiopathic bone marrow failure syndromes (BMF), has raised the importance of the dysplasia of myelodysplastic syndromes (MDS) and has been conducting the prospective registration, central review, and follow-up study of MDS. This group recently proposed the grading system for diagnostic accuracy of MDS, and the detailed procedure of morphological diagnosis of MDS is presented in the specialized color atlas with typical photographs of various dysplasia. JSLH has also approved the grading system for diagnostic accuracy of MDS and adopted this standardized diagnostic system to the educational item for certification of the laboratory hematology specialists, aiming at a nationwidely expanding morphological evaluation of myelodysplasia. Further and significant progress in the standardization of blood cell morphology will be expected in Japan through the activity of JSLH. © 2018 John Wiley & Sons Ltd.

  15. Science Laboratory Environment and Academic Performance

    NASA Astrophysics Data System (ADS)

    Aladejana, Francisca; Aderibigbe, Oluyemisi

    2007-12-01

    The study determined how students assess the various components of their science laboratory environment. It also identified how the laboratory environment affects students' learning outcomes. The modified ex-post facto design was used. A sample of 328 randomly selected students was taken from a population of all Senior Secondary School chemistry students in a state in Nigeria. The research instrument, Science Laboratory Environment Inventory (SLEI) designed and validated by Fraser et al. (Sci Educ 77:1-24, 1993) was administered on the selected students. Data analysis was done using descriptive statistics and Product Moment Correlation. Findings revealed that students could assess the five components (Student cohesiveness, Open-endedness, Integration, Rule clarity, and Material Environment) of the laboratory environment. Student cohesiveness has the highest assessment while material environment has the least. The results also showed that the five components of the science laboratory environment are positively correlated with students' academic performance. The findings are discussed with a view to improving the quality of the laboratory environment, subsequent academic performance in science and ultimately the enrolment and retaining of learners in science.

  16. Implementation research: a mentoring programme to improve laboratory quality in Cambodia

    PubMed Central

    Voeurng, Vireak; Sek, Sophat; Song, Sophanna; Vong, Nora; Tous, Chansamrach; Flandin, Jean-Frederic; Confer, Deborah; Costa, Alexandre; Martin, Robert

    2016-01-01

    Abstract Objective To implement a mentored laboratory quality stepwise implementation (LQSI) programme to strengthen the quality and capacity of Cambodian hospital laboratories. Methods We recruited four laboratory technicians to be mentors and trained them in mentoring skills, laboratory quality management practices and international standard organization (ISO) 15189 requirements for medical laboratories. Separately, we trained staff from 12 referral hospital laboratories in laboratory quality management systems followed by tri-weekly in-person mentoring on quality management systems implementation using the LQSI tool, which is aligned with the ISO 15189 standard. The tool was adapted from a web-based resource into a software-based spreadsheet checklist, which includes a detailed action plan and can be used to qualitatively monitor each laboratory’s progress. The tool – translated into Khmer – included a set of quality improvement activities grouped into four phases for implementation with increasing complexity. Project staff reviewed the laboratories’ progress and challenges in weekly conference calls and bi-monthly meetings with focal points of the health ministry, participating laboratories and local partners. We present the achievements in implementation from September 2014 to March 2016. Findings As of March 2016, the 12 laboratories have completed 74–90% of the 104 activities in phase 1, 53–78% of the 178 activities in phase 2, and 18–26% of the 129 activities in phase 3. Conclusion Regular on-site mentoring of laboratories using a detailed action plan in the local language allows staff to learn concepts of quality management system and learn on the job without disruption to laboratory service provision. PMID:27843164

  17. Laboratory toxicity and benthic invertebrate field colonization of Upper Columbia River sediments: finding adverse effects using multiple lines of evidence.

    PubMed

    Fairchild, J F; Kemble, N E; Allert, A L; Brumbaugh, W G; Ingersoll, C G; Dowling, B; Gruenenfelder, C; Roland, J L

    2012-07-01

    From 1930 to 1995, the Upper Columbia River (UCR) of northeast Washington State received approximately 12 million metric tons of smelter slag and associated effluents from a large smelter facility located in Trail, British Columbia, approximately 10 km north of the United States-Canadian border. Studies conducted during the past two decades have demonstrated the presence of toxic concentrations of heavy metals in slag-based sandy sediments, including cadmium, copper, zinc, and lead in the UCR area as well as the downstream reservoir portion of Lake Roosevelt. We conducted standardized whole-sediment toxicity tests with the amphipod Hyalella azteca (28-day) and the midge Chironomus dilutus (10-day) on 11 samples, including both UCR and study-specific reference sediments. Metal concentrations in sediments were modeled for potential toxicity using three approaches: (1) probable effects quotients (PEQs) based on total recoverable metals (TRMs) and simultaneously extracted metals (SEMs); (2) SEMs corrected for acid-volatile sulfides (AVS; i.e., ∑SEM - AVS); and (3) ∑SEM - AVS normalized to the fractional organic carbon (f(oc)) (i.e., ∑SEM - AVS/f(oc)). The most highly metal-contaminated sample (∑PEQ(TRM) = 132; ∑PEQ(SEM) = 54; ∑SEM - AVS = 323; and ∑SEM - AVS/(foc) = 64,600 umol/g) from the UCR was dominated by weathered slag sediment particles and resulted in 80% mortality and 94% decrease in biomass of amphipods; in addition, this sample significantly decreased growth of midge by 10%. The traditional ∑AVS - SEM, uncorrected for organic carbon, was the most accurate approach for estimating the effects of metals in the UCR. Treatment of the toxic slag sediment with 20% Resinex SIR-300 metal-chelating resin significantly decreased the toxicity of the sample. Samples ∑SEM - AVS > 244 was not toxic to amphipods or midge in laboratory testing, indicating that this value may be an approximate threshold for effects in the UCR. In situ benthic invertebrate

  18. [Study of quality of a branch laboratory--an opinion of a laboratory manager].

    PubMed

    Yazawa, Naoyuki

    2006-11-01

    At the stage of establishing a branch laboratory, quality evaluation is extremely difficult. Even the results of a control survey by the headquarters of the branch laboratory are unhelpful. For a clinical laboratory, the most important function is to provide reliable data all the time, and to maintain the reliability of clinical doctors with informed responses. We mostly refer to control surveys and daily quality control data to evaluate a clinical laboratory, but we rarely check its fundamental abilities, such as planning events, preserving statistical data about the standard range, using the right method for quality control and others. This is generally disregarded and it is taken for granted that they will be correct the first time. From my six years of experience working with X's branch laboratory, I realized that there might be some relation between the quality of a branch laboratory and the fundamental abilities of the company itself. I would never argue that all branch laboratories are ineffective, but they should be conscious of fundamental activities. The referring laboratory, not the referral laboratory, should be responsible for ensuring that the referral laboratory's examination results and findings are correct.

  19. Technology Systems. Laboratory Activities.

    ERIC Educational Resources Information Center

    Brame, Ray; And Others

    This guide contains 43 modules of laboratory activities for technology education courses. Each module includes an instructor's resource sheet and the student laboratory activity. Instructor's resource sheets include some or all of the following elements: module number, course title, activity topic, estimated time, essential elements, objectives,…

  20. The spectrum of aseptic central nervous system infections in southern Germany - demographic, clinical and laboratory findings.

    PubMed

    Kaminski, M; Grummel, V; Hoffmann, D; Berthele, A; Hemmer, B

    2017-08-01

    Aseptic infections of the central nervous system (CNS) are frequently observed in Germany. However, no study has systematically addressed the spectrum of aseptic CNS infections in Germany. Data on 191 adult patients diagnosed from January 2007 to December 2014 with aseptic meningitis or encephalitis/meningoencephalitis at our hospital were collected by chart review and analyzed for demographic, clinical and laboratory findings. Patients were stratified according to the causative virus and findings were compared between groups. In our cohort, meningitis was caused in 36% by enterovirus (EV), 15% by herpes simplex virus (HSV), 12% by varicella zoster virus (VZV) and 5% by tick borne encephalitis (TBE). Encephalitis/meningoencephalitis was caused in 13% by HSV, 13% by VZV, and three out of 11 tested patients were positive for TBE. The highest incidence of EV infections was between 25 and 35 years and of HSV infections between 30 and 60 years. VZV infections had a bimodal distribution peaking below 30 and above 70 years. VZV and EV infections were more frequently observed during summer, whereas HSV infections showed no seasonal preference. Inflammatory changes in cerebrospinal fluid (CSF) were highest in HSV and lowest in EV infections. Polymerase chain reaction tests for HSV, VZV and EV in CSF and TBE serology determined the causative virus in over 60% of tested patients. The age of affected patients, seasonal distribution, disease course and inflammatory changes in CSF differ between groups of patients affected by the most common viral infections. © 2017 EAN.

  1. Sodium phenylbutyrate in Huntington's disease: a dose-finding study.

    PubMed

    Hogarth, Penelope; Lovrecic, Luca; Krainc, Dimitri

    2007-10-15

    Transcriptional dysregulation in Huntington's disease (HD) is mediated in part by aberrant patterns of histone acetylation. We performed a dose-finding study in human HD of sodium phenylbutyrate (SPB), a histone deacetylase inhibitor that ameliorates the HD phenotype in animal models. We used a dose-escalation/de-escalation design, using prespecified toxicity criteria and standard clinical and laboratory safety measures. The maximum tolerated dose was 15 g/day. At higher doses, toxicity included vomiting, lightheadedness, confusion, and gait instability. We saw no significant laboratory or electrocardiographic abnormalities. Gene expression changes in blood suggested an inverse dose-response. In conclusion, SPB at 12 to 15 g/day appears to be safe and well-tolerated in human HD. 2007 Movement Disorder Society

  2. Design and implementation of a hospital-based usability laboratory: insights from a Department of Veterans Affairs laboratory for health information technology.

    PubMed

    Russ, Alissa L; Weiner, Michael; Russell, Scott A; Baker, Darrell A; Fahner, W Jeffrey; Saleem, Jason J

    2012-12-01

    Although the potential benefits of more usable health information technologies (HIT) are substantial-reduced HIT support costs, increased work efficiency, and improved patient safety--human factors methods to improve usability are rarely employed. The US Department of Veterans Affairs (VA) has emerged as an early leader in establishing usability laboratories to inform the design of HIT, including its electronic health record. Experience with a usability laboratory at a VA Medical Center provides insights on how to design, implement, and leverage usability laboratories in the health care setting. The VA Health Services Research and Development Service Human-Computer Interaction & Simulation Laboratory emerged as one of the first VA usability laboratories and was intended to provide research-based findings about HIT designs. This laboratory supports rapid prototyping, formal usability testing, and analysis tools to assess existing technologies, alternative designs, and potential future technologies. RESULTS OF IMPLEMENTATION: Although the laboratory has maintained a research focus, it has become increasingly integrated with VA operations, both within the medical center and on a national VA level. With this resource, data-driven recommendations have been provided for the design of HIT applications before and after implementation. The demand for usability testing of HIT is increasing, and information on how to develop usability laboratories for the health care setting is often needed. This article may assist other health care organizations that want to invest in usability resources to improve HIT. The establishment and utilization of usability laboratories in the health care setting may improve HIT designs and promote safe, high-quality care for patients.

  3. Communication and the laboratory physician

    PubMed Central

    Penistan, J. L.

    1973-01-01

    A clinical laboratory documentation system is described, suitable for community hospitals without computer services. The system is cumulative and is designed to provide the laboratory physician with the clinical information necessary for intelligent review and comment on the laboratory's findings. The mode of presentation of requests to the laboratory and lay-out of the reports to the clinicians are designed to make the two-way communication as close and personal as possible; to encourage the selection of those investigations likely to prove rewarding, and to discourage unnecessary investigation. The possibility of important data escaping notice is minimized. The system is economical in capital equipment, labour and supplies. PMID:4758594

  4. Laboratory toxicity and benthic invertebrate field colonization of Upper Columbia River sediments: Finding adverse effects using multiple lines of evidence

    USGS Publications Warehouse

    Fairchild, J.F.; Kemble, N.E.; Allert, A.L.; Brumbaugh, W.G.; Ingersoll, C.G.; Dowling, B.; Gruenenfelder, C.; Roland, J.L.

    2012-01-01

    From 1930 to 1995, the Upper Columbia River (UCR) of northeast Washington State received approximately 12 million metric tons of smelter slag and associated effluents from a large smelter facility located in Trail, British Columbia, approximately 10 km north of the United States–Canadian border. Studies conducted during the past two decades have demonstrated the presence of toxic concentrations of heavy metals in slag-based sandy sediments, including cadmium, copper, zinc, and lead in the UCR area as well as the downstream reservoir portion of Lake Roosevelt. We conducted standardized whole-sediment toxicity tests with the amphipod Hyalella azteca (28-day) and the midge Chironomus dilutus (10-day) on 11 samples, including both UCR and study-specific reference sediments. Metal concentrations in sediments were modeled for potential toxicity using three approaches: (1) probable effects quotients (PEQs) based on total recoverable metals (TRMs) and simultaneously extracted metals (SEMs); (2) SEMs corrected for acid-volatile sulfides (AVS; i.e., ∑SEM − AVS); and (3) ∑SEM − AVS normalized to the fractional organic carbon (foc) (i.e., ∑SEM − AVS/foc). The most highly metal-contaminated sample (∑PEQTRM = 132; ∑PEQSEM = 54; ∑SEM − AVS = 323; and ∑SEM − AVS/foc = 64,600 umol/g) from the UCR was dominated by weathered slag sediment particles and resulted in 80% mortality and 94% decrease in biomass of amphipods; in addition, this sample significantly decreased growth of midge by 10%. The traditional ∑AVS – SEM, uncorrected for organic carbon, was the most accurate approach for estimating the effects of metals in the UCR. Treatment of the toxic slag sediment with 20% Resinex SIR-300 metal-chelating resin significantly decreased the toxicity of the sample. Samples ∑SEM − AVS > 244 was not toxic to amphipods or midge in laboratory testing, indicating that this value may be an approximate threshold for effects in the UCR

  5. FRESHWATER FINDINGS, 1979-1982: RESEARCH PUBLICATIONS OF THE ENVIRONMENTAL RESEARCH LABORATORY, DULUTH, MINNESOTA

    EPA Science Inventory

    This report contains citations of publications for the years 1979-1982 on research conducted or supported by the Environmental Research Laboratory-Duluth. All published material has been organized into two major categories: (1) Journal Articles, Book Chapters, Proceedings, etc., ...

  6. [Cowpox virus infection in an alpaca (Vicugna pacos) - clinical symptoms, laboratory diagnostic findings and pathological changes].

    PubMed

    Goerigk, D; Theuß, T; Pfeffer, M; Konrath, A; Kalthoff, D; Woll, D; Vahlenkamp, T W; Beer, M; Starke, A

    2014-01-01

    Orthopoxvirus infections appear to be rare in South American Camelids, because only a few cases have been reported in the literature. Based on a generalized infection with cowpox virus in an alpaca, the clinical symptoms, laboratory diagnostic findings and the pathological changes are described. The case history showed a long treatment because of chronic skin lesions. The main clinical symptom was miliary papules over the entire skin. Furthermore, a bilateral mucopurulent conjunctivitis occurred as well as excessive salivation due to a severe erosive-ulcerative stomatitis. Although the animal received intensive treatment, it died 8 days after admission to the clinic. During necropsy, an erosive-ulcerative laryngitis as well as a necrotising pneumonia and lymphadenitis were observed. Histopathological examination of representative organ samples led to the diagnosis of a suspected orthopoxvirus infection. Electron microscopy and quantitative polymerase chain reaction (qPCR) of tissue samples confirmed this diagnosis. The virus could be isolated in tissue culture and a PCR with subsequent nucleotide sequencing identified cowpox virus as the causative agent for this generalised infection.

  7. Evaluation of hs-CRP and visseral adiposity index in patients with policystic ovary syndrome by clinical and laboratory findings.

    PubMed

    Ün, B; Dolapçıoğlu, K S; Güler Okyay, A; Şahin, H; Beyazıt, A

    2016-09-01

    In this study, we aimed to evaluate two cardiovascular risk markers, hs-CRP and visseral adiposity index, in patients with policystic ovary syndrome in association with clinical and laboratory findings. Study group included 75 patients who were diagnosed as PCOS according to the criteria of AE-PCOS 2006 and control group included 75 non-PCOS patients who were subsequently admitted to outpatient clinic for smear control, with urinary or vaginal symptoms. Physical and sonographic examinations were made to all subjects. Mean arterial pressure, waist/hip ratio and body mass index were calculated. Fasting blood glucose and insulin, HbA1c, lipids, high sensitivity C-reactive protein (hs-CRP), estradiol, follicle stimulating hormon, luteinising hormone, tiroid stimulating hormone, prolaktin, total testosteron and sex hormone binding globulin were tested in venous blood samples collected from cases following overnight fast in follicular phase of spontaneous or induced menstruation. Visceral adiposity index was also calculated. No statistically significant difference was found between PCOS group and control group concerning hs-CRP and VAI (p>0.05). When patients in PCOS group were further grouped as obese and non-obese, hs-CRP and VAI values in obese group were significantly higher than those in non-obese group (p<0.001). However, when control group were further grouped as obese and non-obese, there was no significant difference in terms of hs-CRP between groups (p>0.05), VAI values were significantly higher in obese control group (p<0.05). According to the results of our study, hs-CRP stands for a better and more specific marker than VAI to determine metabolic components and predictive risks for cardiovascular diseases in patients with PCOS. Further studies with larger populations are needed in order to determine cardiovascular risks particularly in young PCOS patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Multiweek cell culture project for use in upper-level biology laboratories.

    PubMed

    Marion, Rebecca E; Gardner, Grant E; Parks, Lisa D

    2012-06-01

    This article describes a laboratory protocol for a multiweek project piloted in a new upper-level biology laboratory (BIO 426) using cell culture techniques. Human embryonic kidney-293 cells were used, and several culture media and supplements were identified for students to design their own experiments. Treatments included amino acids, EGF, caffeine, epinephrine, heavy metals, and FBS. Students researched primary literature to determine their experimental variables, made their own solutions, and treated their cells over a period of 2 wk. Before this, a sterile technique laboratory was developed to teach students how to work with the cells and minimize contamination. Students designed their experiments, mixed their solutions, seeded their cells, and treated them with their control and experimental media. Students had the choice of manipulating a number of variables, including incubation times, exposure to treatment media, and temperature. At the end of the experiment, students observed the effects of their treatment, harvested and dyed their cells, counted relative cell numbers in control and treatment flasks, and determined the ratio of living to dead cells using a hemocytometer. At the conclusion of the experiment, students presented their findings in a poster presentation. This laboratory can be expanded or adapted to include additional cell lines and treatments. The ability to design and implement their own experiments has been shown to increase student engagement in the biology-related laboratory activities as well as develop the critical thinking skills needed for independent research.

  9. Developing an online chemistry laboratory for non-chemistry majors

    NASA Astrophysics Data System (ADS)

    Poole, Jacqueline H.

    Distance education, also known as online learning, is student-centered/self-directed educational opportunities. This style of learning is expanding in scope and is increasingly being accepted throughout the academic curriculum as a result of its flexibility for the student as well as the cost-effectiveness for the institution. Nevertheless, the introduction of online science courses including chemistry and physics have lagged behind due to the challenge of re-creation of the hands-on laboratory learning experience. This dissertation looks at the effectiveness of the design of a series of chemistry laboratory experiments for possible online delivery that provide students with simulated hands-on experiences. One class of college Chemistry 101 students conducted chemistry experiments inside and outside of the physical laboratory using instructions on Blackboard and Late Nite Labs(TM). Learning outcomes measured by (a) pretests, (b) written laboratory reports, (c) posttest assessments, (d) student reactions as determined by a questionnaire, and (e) a focus group interview were utilized to compare both types of laboratory experiences. The research findings indicated learning outcomes achieved by students outside of the traditional physical laboratory were statistically greater than the equivalent face-to-face instruction in the traditional laboratory. Evidence from student reactions comparing both types of laboratory formats (online and traditional face-to-face) indicated student preference for the online laboratory format. The results are an initial contribution to the design of a complete sequence of experiments that can be performed independently by online students outside of the traditional face-to-face laboratory that will satisfy the laboratory requirement for the two-semester college Chemistry 101 laboratory course.

  10. Multidrug-resistant typhoid fever with neurologic findings on the Malawi-Mozambique border.

    PubMed

    Lutterloh, Emily; Likaka, Andrew; Sejvar, James; Manda, Robert; Naiene, Jeremias; Monroe, Stephan S; Khaila, Tadala; Chilima, Benson; Mallewa, Macpherson; Kampondeni, Sam D; Lowther, Sara A; Capewell, Linda; Date, Kashmira; Townes, David; Redwood, Yanique; Schier, Joshua G; Nygren, Benjamin; Tippett Barr, Beth; Demby, Austin; Phiri, Abel; Lungu, Rudia; Kaphiyo, James; Humphrys, Michael; Talkington, Deborah; Joyce, Kevin; Stockman, Lauren J; Armstrong, Gregory L; Mintz, Eric

    2012-04-01

    Salmonella enterica serovar Typhi causes an estimated 22 million cases of typhoid fever and 216 000 deaths annually worldwide. We investigated an outbreak of unexplained febrile illnesses with neurologic findings, determined to be typhoid fever, along the Malawi-Mozambique border. The investigation included active surveillance, interviews, examinations of ill and convalescent persons, medical chart reviews, and laboratory testing. Classification as a suspected case required fever and ≥1 other finding (eg, headache or abdominal pain); a probable case required fever and a positive rapid immunoglobulin M antibody test for typhoid (TUBEX TF); a confirmed case required isolation of Salmonella Typhi from blood or stool. Isolates underwent antimicrobial susceptibility testing and subtyping by pulsed-field gel electrophoresis (PFGE). We identified 303 cases from 18 villages with onset during March-November 2009; 214 were suspected, 43 were probable, and 46 were confirmed cases. Forty patients presented with focal neurologic abnormalities, including a constellation of upper motor neuron signs (n = 19), ataxia (n = 22), and parkinsonism (n = 8). Eleven patients died. All 42 isolates tested were resistant to ampicillin, chloramphenicol, and trimethoprim-sulfamethoxazole; 4 were also resistant to nalidixic acid. Thirty-five of 42 isolates were indistinguishable by PFGE. The unusual neurologic manifestations posed a diagnostic challenge that was resolved through rapid typhoid antibody testing in the field and subsequent blood culture confirmation in the Malawi national reference laboratory. Extending laboratory diagnostic capacity, including blood culture, to populations at risk for typhoid fever in Africa will improve outbreak detection, response, and clinical treatment.

  11. Laboratory Astrophysics White Paper: Summary of Laboratory Astrophysics Needs

    NASA Technical Reports Server (NTRS)

    2002-01-01

    The NASA Laboratory Astrophysics Workshop (NASA LAW) met at NASA Ames Research Center from 1-3 May 2002 to assess the role that laboratory astrophysics plays in the optimization of NASA missions, both at the science conception level and at the science return level. Space missions provide understanding of fundamental questions regarding the origin and evolution of galaxies, stars, and planetary systems. In all of these areas the interpretation of results from NASA's space missions relies crucially upon data obtained from the laboratory. We stress that Laboratory Astrophysics is important not only in the interpretation of data, but also in the design and planning of future missions. We recognize a symbiosis between missions to explore the universe and the underlying basic data needed to interpret the data from those missions. In the following we provide a summary of the consensus results from our Workshop, starting with general programmatic findings and followed by a list of more specific scientific areas that need attention. We stress that this is a 'living document' and that these lists are subject to change as new missions or new areas of research rise to the fore.

  12. Dental Laboratory Technology.

    ERIC Educational Resources Information Center

    Department of the Air Force, Washington, DC.

    The Air Force dental laboratory technology manual is designed as a basic training text as well as a reference source for dental laboratory technicians, a specialty occupation concerned with the design, fabrication, and repair of dental prostheses. Numerous instructive diagrams and photographs are included throughout the manual. The comprehensive…

  13. 42 CFR 493.1850 - Laboratory registry.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Laboratory registry. 493.1850 Section 493.1850... (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Enforcement Procedures § 493.1850 Laboratory... laboratories, including the following: (1) A list of laboratories that have been convicted, under Federal or...

  14. 42 CFR 493.1850 - Laboratory registry.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Laboratory registry. 493.1850 Section 493.1850... (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Enforcement Procedures § 493.1850 Laboratory... laboratories, including the following: (1) A list of laboratories that have been convicted, under Federal or...

  15. Maximising Resource Allocation in the Teaching Laboratory: Understanding Student Evaluations of Teaching Assistants in a Team-Based Teaching Format

    ERIC Educational Resources Information Center

    Nikolic, Sasha; Suesse, Thomas F.; McCarthy, Timothy J.; Goldfinch, Thomas L.

    2017-01-01

    Minimal research papers have investigated the use of student evaluations on the laboratory, a learning medium usually run by teaching assistants with little control of the content, delivery and equipment. Finding the right mix of teaching assistants for the laboratory can be an onerous task due to the many skills required including theoretical and…

  16. Creep Laboratory manual

    NASA Astrophysics Data System (ADS)

    Osgerby, S.; Loveday, M. S.

    1992-06-01

    A manual for the NPL Creep Laboratory, a collective name given to two testing laboratories, the Uniaxial Creep Laboratory and the Advanced High Temperature Mechanical Testing Laboratory, is presented. The first laboratory is devoted to uniaxial creep testing and houses approximately 50 high sensitivity creep machines including 10 constant stress cam lever machines. The second laboratory houses a low cycle fatigue testing machine of 100 kN capacity driven by a servo-electric actuator, five machines for uniaxial tensile creep testing of engineering ceramics at temperatures up to 1600C, and an electronic creep machine. Details of the operational procedures for carrying out uniaxial creep testing are given. Calibration procedures to be followed in order to comply with the specifications laid down by British standards, and to provide traceability back to the primary standards are described.

  17. Identification of Medically Actionable Secondary Findings in the 1000 Genomes

    PubMed Central

    Olfson, Emily; Cottrell, Catherine E.; Davidson, Nicholas O.; Gurnett, Christina A.; Heusel, Jonathan W.; Stitziel, Nathan O.; Chen, Li-Shiun; Hartz, Sarah; Nagarajan, Rakesh; Saccone, Nancy L.; Bierut, Laura J.

    2015-01-01

    The American College of Medical Genetics and Genomics (ACMG) recommends that clinical sequencing laboratories return secondary findings in 56 genes associated with medically actionable conditions. Our goal was to apply a systematic, stringent approach consistent with clinical standards to estimate the prevalence of pathogenic variants associated with such conditions using a diverse sequencing reference sample. Candidate variants in the 56 ACMG genes were selected from Phase 1 of the 1000 Genomes dataset, which contains sequencing information on 1,092 unrelated individuals from across the world. These variants were filtered using the Human Gene Mutation Database (HGMD) Professional version and defined parameters, appraised through literature review, and examined by a clinical laboratory specialist and expert physician. Over 70,000 genetic variants were extracted from the 56 genes, and filtering identified 237 variants annotated as disease causing by HGMD Professional. Literature review and expert evaluation determined that 7 of these variants were pathogenic or likely pathogenic. Furthermore, 5 additional truncating variants not listed as disease causing in HGMD Professional were identified as likely pathogenic. These 12 secondary findings are associated with diseases that could inform medical follow-up, including cancer predisposition syndromes, cardiac conditions, and familial hypercholesterolemia. The majority of the identified medically actionable findings were in individuals from the European (5/379) and Americas (4/181) ancestry groups, with fewer findings in Asian (2/286) and African (1/246) ancestry groups. Our results suggest that medically relevant secondary findings can be identified in approximately 1% (12/1092) of individuals in a diverse reference sample. As clinical sequencing laboratories continue to implement the ACMG recommendations, our results highlight that at least a small number of potentially important secondary findings can be selected for

  18. Laboratory hemostasis: milestones in Clinical Chemistry and Laboratory Medicine.

    PubMed

    Lippi, Giuseppe; Favaloro, Emmanuel J

    2013-01-01

    Hemostasis is a delicate, dynamic and intricate system, in which pro- and anti-coagulant forces cooperate for either maintaining blood fluidity under normal conditions, or else will prompt blood clot generation to limit the bleeding when the integrity of blood vessels is jeopardized. Excessive prevalence of anticoagulant forces leads to hemorrhage, whereas excessive activation of procoagulant forces triggers excessive coagulation and thrombosis. The hemostasis laboratory performs a variety of first, second and third line tests, and plays a pivotal role in diagnostic and monitoring of most hemostasis disturbances. Since the leading targets of Clinical Chemistry and Laboratory Medicine include promotion of progress in fundamental and applied research, along with publication of guidelines and recommendations in laboratory diagnostics, this journal is an ideal source of information on current developments in the laboratory technology of hemostasis, and this article is aimed to celebrate some of the most important and popular articles ever published by the journal in the filed of laboratory hemostasis.

  19. Challenges in small screening laboratories: implementing an on-demand laboratory information management system.

    PubMed

    Lemmon, Vance P; Jia, Yuanyuan; Shi, Yan; Holbrook, S Douglas; Bixby, John L; Buchser, William

    2011-11-01

    The Miami Project to Cure Paralysis, part of the University of Miami Miller School of Medicine, includes a laboratory devoted to High Content Analysis (HCA) of neurons. The goal of the laboratory is to uncover signaling pathways, genes, compounds, or drugs that can be used to promote nerve growth. HCA permits the quantification of neuronal morphology, including the lengths and numbers of axons. HCA of various libraries on primary neurons requires a team-based approach, a variety of process steps and complex manipulations of cells and libraries to obtain meaningful results. HCA itself produces vast amounts of information including images, well-based data and cell-based phenotypic measures. Documenting and integrating the experimental workflows, library data and extensive experimental results is challenging. For academic laboratories generating large data sets from experiments involving thousands of perturbagens, a Laboratory Information Management System (LIMS) is the data tracking solution of choice. With both productivity and efficiency as driving rationales, the Miami Project has equipped its HCA laboratory with an On Demand or Software As A Service (SaaS) LIMS to ensure the quality of its experiments and workflows. The article discusses how the system was selected and integrated into the laboratory. The advantages of a SaaS based LIMS over a client-server based system are described. © 2011 Bentham Science Publishers

  20. Estimating implementation and operational costs of an integrated tiered CD4 service including laboratory and point of care testing in a remote health district in South Africa.

    PubMed

    Cassim, Naseem; Coetzee, Lindi M; Schnippel, Kathryn; Glencross, Deborah K

    2014-01-01

    An integrated tiered service delivery model (ITSDM) has been proposed to provide 'full-coverage' of CD4 services throughout South Africa. Five tiers are described, defined by testing volumes and number of referring health-facilities. These include: (1) Tier-1/decentralized point-of-care service (POC) in a single site; Tier-2/POC-hub servicing processing < 30-40 samples from 8-10 health-clinics; Tier-3/Community laboratories servicing ∼ 50 health-clinics, processing < 150 samples/day; high-volume centralized laboratories (Tier-4 and Tier-5) processing < 300 or > 600 samples/day and serving > 100 or > 200 health-clinics, respectively. The objective of this study was to establish costs of existing and ITSDM-tiers 1, 2 and 3 in a remote, under-serviced district in South Africa. Historical health-facility workload volumes from the Pixley-ka-Seme district, and the total volumes of CD4 tests performed by the adjacent district referral CD4 laboratories, linked to locations of all referring clinics and related laboratory-to-result turn-around time (LTR-TAT) data, were extracted from the NHLS Corporate-Data-Warehouse for the period April-2012 to March-2013. Tiers were costed separately (as a cost-per-result) including equipment, staffing, reagents and test consumable costs. A one-way sensitivity analyses provided for changes in reagent price, test volumes and personnel time. The lowest cost-per-result was noted for the existing laboratory-based Tiers- 4 and 5 ($6.24 and $5.37 respectively), but with related increased LTR-TAT of > 24-48 hours. Full service coverage with TAT < 6-hours could be achieved with placement of twenty-seven Tier-1/POC or eight Tier-2/POC-hubs, at a cost-per-result of $32.32 and $15.88 respectively. A single district Tier-3 laboratory also ensured 'full service coverage' and < 24 hour LTR-TAT for the district at $7.42 per-test. Implementing a single Tier-3/community laboratory to extend and improve delivery of services in Pixley-ka-Seme, with an

  1. If You Don't Have a Good Laboratory, Find a Good Volcano: Mount Vesuvius as a Natural Chemical Laboratory in Eighteenth-Century Italy.

    PubMed

    Guerra, Corinna

    2015-08-01

    This essay that examines the role of the volcano as a chemical site in the late eighteenth century, as the "new chemistry" spread throughout the southern Italian Kingdom of Naples, resulting in lively debates. In Naples itself, these scientific debates were not confined to academies, courts, and urban spaces. In the absence of well-equipped chemical laboratories, Neapolitan scholars also carried out research on chemistry on the slopes of Mount Vesuvius, a natural site that furnished them with all the tools and substances necessary for practising chemistry. By examining various Neapolitan publications on Vesuvius and the chemical reactions and products associated with its periodic eruptions, I argue that the volcano's presence contributed to a distinctive, local approach to chemical theory and practice. Several case studies examine the ways in which proximity to Vesuvius was exploited by Neapolitan scholars as they engaged with the new chemistry, including Giuseppe Vairo, Michele Ferrara, Francesco Semmola, and Emanuele Scotti.

  2. In or out? Methodological considerations for including and excluding findings from a meta-analysis of predictors of antiretroviral adherence in HIV-positive women

    PubMed Central

    Voils, Corrine I.; Barroso, Julie; Hasselblad, Victor; Sandelowski, Margarete

    2008-01-01

    Aim This paper is a discussion detailing the decisions concerning whether to include or exclude findings from a meta-analysis of report of quantitative studies of antiretroviral adherence in HIV-positive women. Background Publication constraints and the absence of reflexivity as a criterion for validity in, and reporting of, quantitative research preclude detailing the many judgements made in the course of a meta-analysis. Yet, such an accounting would assist researchers better to address the unique challenges to meta-analysis presented by the bodies of research they have targeted for review, and to show the subjectivity, albeit disciplined, that characterizes the meta-analytic process. Data sources Data were 29 published and unpublished studies on antiretroviral adherence in HIV-positive women of any race/ethnicity, class, or nationality living in the United States of America. The studies were retrieved between June 2005 and January 2006 using 40 databases. Review methods Findings were included if they met the statistical assumptions of meta-analysis, including: (1) normal distribution of observations; (2) homogeneity of variances; and (3) independence of observations. Results Relevant studies and findings were excluded because of issues related to differences in study design, different operationalizations of dependent and independent variables, multiple cuts from common longitudinal data sets, and presentation of unadjusted and adjusted findings. These reasons led to the exclusion of 73% of unadjusted relationships and 87% of adjusted relationships from our data set, leaving few findings to synthesize. Conclusion Decisions made during research synthesis studies may result in more information losses than gains, thereby obliging researchers to find ways to preserve findings that are potentially valuable for practice. PMID:17543011

  3. Staffing benchmarks for clinical laboratories: a College of American Pathologists Q-Probes study of laboratory staffing at 98 institutions.

    PubMed

    Jones, Bruce A; Darcy, Teresa; Souers, Rhona J; Meier, Frederick A

    2012-02-01

    Publicly available information concerning laboratory staffing benchmarks is scarce. One of the few publications on this topic summarized the findings of a Q-Probes study performed in 2004. This publication reports a similar survey with data collected in 2010. To assess the relationship between staffing levels in specified laboratory sections and test volumes in these sections and quantify management span of control. The study defined 4 laboratory sections: anatomic pathology (including cytology), chemistry/hematology/immunology, microbiology, and transfusion medicine. It divided staff into 3 categories: management, nonmanagement (operational or bench staff), and doctoral (MD, PhD) supervisory staff. People in these categories were tabulated as full-time equivalents and exclusions specified. Tests were counted in uniform formats, specified for each laboratory section, according to Medicare rules for the bundling and unbundling of tests. Ninety-eight participating institutions provided data that showed significant associations between test volumes and staffing for all 4 sections. There was wide variation in productivity based on volume. There was no relationship between testing volume per laboratory section and management span of control. Higher productivity in chemistry/hematology/immunology was associated with a higher fraction of tests coming from nonacute care patients. In both the 2004 and 2010 studies, productivity was inseparably linked to test volume. Higher test volume was associated with higher productivity ratios in chemistry/hematology/immunology and transfusion medicine sections. The impact of various testing services on productivity is section-specific.

  4. Introductory Archaeology: The Inexpensive Laboratory.

    ERIC Educational Resources Information Center

    Rice, Patricia C.

    1990-01-01

    Describes a number of student-focused laboratory exercises that are inexpensive, yet show the scientific character of archaeology. Describes the environmental laboratory exercise which includes the following analysis topics: (1) pollen; (2) earth core; (3) microfaunal; and (4) microwear. Describes the ceramic laboratory which involves…

  5. Chemistry laboratory safety manual available

    NASA Technical Reports Server (NTRS)

    Elsbrock, R. G.

    1968-01-01

    Chemistry laboratory safety manual outlines safe practices for handling hazardous chemicals and chemistry laboratory equipment. Included are discussions of chemical hazards relating to fire, health, explosion, safety equipment and procedures for certain laboratory techniques and manipulations involving glassware, vacuum equipment, acids, bases, and volatile solvents.

  6. Cushing Syndrome in Carney Complex: Clinical, Pathologic, and Molecular Genetic Findings in the 17 Affected Mayo Clinic Patients.

    PubMed

    Lowe, Kathleen M; Young, William F; Lyssikatos, Charalampos; Stratakis, Constantine A; Carney, J Aidan

    2017-02-01

    Carney complex (CNC) is a rare dominantly inherited multiorgan tumoral disorder that includes Cushing syndrome (CS). To establish the Mayo Clinic experience with the CS component, including its clinical, laboratory, and pathologic findings, we performed a retrospective search of the patient and pathologic databases of Mayo Clinic in Rochester, MN, for patients with CNC and clinical or laboratory findings of CS. Thirty-seven patients with CNC were identified. Twenty-nine had clinical, pathologic, or laboratory evidence of an adrenocortical disorder. Seventeen had classic CS; 15 underwent bilateral, subtotal, or partial unilateral adrenalectomy, and 2 had no treatment. Pathologically, the glands were normal sized or slightly enlarged with multiple small (1 to 4 mm), brown, black, and yellow micronodules (primary pigmented nodular adrenocortical disease; PPNAD). Three glands each had a mass: a 2 cm adenoma, a 1.5 cm macronodule, and an unencapsulated 1.8 cm myelolipoma. Fourteen of the patients were alive at follow-up, and 3 were deceased; 2 of the latter had PPNAD at autopsy, and the third had PPNAD at surgery. Twelve patients without clinical features of classic CS had abnormal adrenocortical testing results; none developed classic CS during follow-up (mean, 10 y). Autopsy findings in 1 showed bilateral vacuolated cell cortical hyperplasia.

  7. Laboratory compliance with the American Society of Clinical Oncology/college of American Pathologists guidelines for human epidermal growth factor receptor 2 testing: a College of American Pathologists survey of 757 laboratories.

    PubMed

    Nakhleh, Raouf E; Grimm, Erin E; Idowu, Michael O; Souers, Rhona J; Fitzgibbons, Patrick L

    2010-05-01

    To ensure quality human epidermal growth receptor 2 (HER2) testing in breast cancer, the American Society of Clinical Oncology/College of American Pathologists guidelines were introduced with expected compliance by 2008. To assess the effect these guidelines have had on pathology laboratories and their ability to address key components. In late 2008, a survey was distributed with the HER2 immunohistochemistry (IHC) proficiency testing program. It included questions regarding pathology practice characteristics and assay validation using fluorescence in situ hybridization or another IHC laboratory assay and assessed pathologist HER2 scoring competency. Of the 907 surveys sent, 757 (83.5%) were returned. The median laboratory accessioned 15 000 cases and performed 190 HER2 tests annually. Quantitative computer image analysis was used by 33% of laboratories. In-house fluorescence in situ hybridization was performed in 23% of laboratories, and 60% of laboratories addressed the 6- to 48-hour tissue fixation requirement by embedding tissue on the weekend. HER2 testing was performed on the initial biopsy in 40%, on the resection specimen in 6%, and on either in 56% of laboratories. Testing was validated with only fluorescence in situ hybridization in 47% of laboratories, whereas 10% of laboratories used another IHC assay only; 13% used both assays, and 12% and 15% of laboratories had not validated their assays or chose "not applicable" on the survey question, respectively. The 90% concordance rate with fluorescence in situ hybridization results was achieved by 88% of laboratories for IHC-negative findings and by 81% of laboratories for IHC-positive cases. The 90% concordance rate for laboratories using another IHC assay was achieved by 80% for negative findings and 75% for positive cases. About 91% of laboratories had a pathologist competency assessment program. This survey demonstrates the extent and characteristics of HER2 testing. Although some American Society of

  8. Clinical, ultrasonographic, and laboratory findings in 12 llamas and 12 alpacas with malignant round cell tumors

    PubMed Central

    Martin, Jeanne M.; Valentine, Beth A.; Cebra, Christopher K.

    2010-01-01

    Clinical signs, duration of illness, clinicopathologic findings, and ultrasonographic findings were evaluated in 12 llamas and 12 alpacas with malignant round cell tumors (MRCT). All but 1 animal died or was euthanized. Common clinical findings were anorexia, recumbency or weakness, and weight loss or poor growth. Peripheral lymphadenomegaly occurred in only 7 animals and was detected more often at necropsy than during physical examination. Common clinicopathologic abnormalities were hypoalbuminemia, acidosis, azotemia, anemia, hyperglycemia, and neutrophilia. Ultrasonography detected tumors in 4/6 animals. Cytologic evaluation of fluid or tissue aspirates or histopathology of biopsy tissue was diagnostic in 5/6 cases. A clinical course of 2 wk or less prior to death or euthanasia was more common in animals ≤ 2 y of age (9/11) than in older animals (6/13). Regular examination of camelids to include clinical pathology and evaluation of peripheral lymph nodes may result in early detection of MCRT. PMID:21358931

  9. Laboratory-based versus non-laboratory-based method for assessment of cardiovascular disease risk: the NHANES I Follow-up Study cohort

    PubMed Central

    Gaziano, Thomas A; Young, Cynthia R; Fitzmaurice, Garrett; Atwood, Sidney; Gaziano, J Michael

    2008-01-01

    Summary Background Around 80% of all cardiovascular deaths occur in developing countries. Assessment of those patients at high risk is an important strategy for prevention. Since developing countries have limited resources for prevention strategies that require laboratory testing, we assessed if a risk prediction method that did not require any laboratory tests could be as accurate as one requiring laboratory information. Methods The National Health and Nutrition Examination Survey (NHANES) was a prospective cohort study of 14 407 US participants aged between 25–74 years at the time they were first examined (between 1971 and 1975). Our follow-up study population included participants with complete information on these surveys who did not report a history of cardiovascular disease (myocardial infarction, heart failure, stroke, angina) or cancer, yielding an analysis dataset N=6186. We compared how well either method could predict first-time fatal and non-fatal cardiovascular disease events in this cohort. For the laboratory-based model, which required blood testing, we used standard risk factors to assess risk of cardiovascular disease: age, systolic blood pressure, smoking status, total cholesterol, reported diabetes status, and current treatment for hypertension. For the non-laboratory-based model, we substituted body-mass index for cholesterol. Findings In the cohort of 6186, there were 1529 first-time cardiovascular events and 578 (38%) deaths due to cardiovascular disease over 21 years. In women, the laboratory-based model was useful for predicting events, with a c statistic of 0·829. The c statistic of the non-laboratory-based model was 0·831. In men, the results were similar (0·784 for the laboratory-based model and 0·783 for the non-laboratory-based model). Results were similar between the laboratory-based and non-laboratory-based models in both men and women when restricted to fatal events only. Interpretation A method that uses non-laboratory

  10. 21 CFR 606.140 - Laboratory controls.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 7 2012-04-01 2012-04-01 false Laboratory controls. 606.140 Section 606.140 Food... CURRENT GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS Laboratory Controls § 606.140 Laboratory controls. Laboratory control procedures shall include: (a) The establishment of scientifically...

  11. 21 CFR 606.140 - Laboratory controls.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Laboratory controls. 606.140 Section 606.140 Food... CURRENT GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS Laboratory Controls § 606.140 Laboratory controls. Laboratory control procedures shall include: (a) The establishment of scientifically...

  12. 21 CFR 606.140 - Laboratory controls.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Laboratory controls. 606.140 Section 606.140 Food... CURRENT GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS Laboratory Controls § 606.140 Laboratory controls. Laboratory control procedures shall include: (a) The establishment of scientifically...

  13. 21 CFR 606.140 - Laboratory controls.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 7 2014-04-01 2014-04-01 false Laboratory controls. 606.140 Section 606.140 Food... CURRENT GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS Laboratory Controls § 606.140 Laboratory controls. Laboratory control procedures shall include: (a) The establishment of scientifically...

  14. Measuring Dynamic Kidney Function in an Undergraduate Physiology Laboratory

    ERIC Educational Resources Information Center

    Medler, Scott; Harrington, Frederick

    2013-01-01

    Most undergraduate physiology laboratories are very limited in how they treat renal physiology. It is common to find teaching laboratories equipped with the capability for high-resolution digital recordings of physiological functions (muscle twitches, ECG, action potentials, respiratory responses, etc.), but most urinary laboratories still rely on…

  15. Towards the development of laboratory methods for studying drinking games: Initial findings, methodological considerations, and future directions

    PubMed Central

    Silvestri, Mark M.; Lewis, Jennifer M.; Borsari, Brian; Correia, Christopher J.

    2014-01-01

    Background Drinking games are prevalent among college students and are associated with increased alcohol use and negative alcohol-related consequences. There has been substantial growth in research on drinking games. However, the majority of published studies rely on retrospective self-reports of behavior and very few studies have made use of laboratory procedures to systematically observe drinking game behavior. Objectives The current paper draws on the authors’ experiences designing and implementing methods for the study of drinking games in the laboratory. Results The paper addressed the following key design features: (a) drinking game selection; (b) beverage selection; (c) standardizing game play; (d) selection of dependent and independent variables; and (e) creating a realistic drinking game environment. Conclusions The goal of this methodological review paper is to encourage other researchers to pursue laboratory research on drinking game behavior. Use of laboratory-based methodologies will facilitate a better understanding of the dynamics of risky drinking and inform prevention and intervention efforts. PMID:25192209

  16. The impact of automating laboratory request forms on the quality of healthcare services.

    PubMed

    Dogether, Majed Al; Muallem, Yahya Al; Househ, Mowafa; Saddik, Basema; Khalifa, Mohamed

    In recent decades, healthcare organizations have undergone a significant transformation with the integration of Information and Communication Technologies within healthcare operations to improve healthcare services. Various technologies such as Hospital Information Systems (HIS), Electronic Health Records (EHR) and Laboratory Information Systems (LIS) have been incorporated into healthcare services. The aim of this study is to evaluate the completeness of outpatients' laboratory paper based request forms in comparison with a electronic laboratory request system. This study was carried out in the laboratory department at King Abdulaziz Medical City (KAMC), National Guard Health Affairs, Riyadh, Saudi Arabia. We used a sample size calculator for comparing two proportions. We estimated the sample size to be 228 for each group. Any laboratory requests including paper and electronic forms were included. We categorized the clarity of the forms into understandable, readable, and unclear. A total of 57 incomplete paper forms or 25% were identified as being incomplete. For electronic forms, there were no incomplete fields, as all fields were mandatory, therefore, rendering them complete. The total of understandable paper-based laboratory forms was 11.4%. Additionally, it was found that the total of readable was 33.8% and the total for unclear was 54.8%, while for electronic-based forms, there were no unclear forms. Electronic based laboratory forms provide a more complete, accurate, clear, and understandable format than paper-based laboratory records. Based on these findings, KAMC should move toward the implementation of electronic-based laboratory request forms for the outpatient laboratory department. Copyright © 2016 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  17. The performance assessment of undergraduate students in physics laboratory by using guided inquiry

    NASA Astrophysics Data System (ADS)

    Mubarok, H.; Lutfiyah, A.; Kholiq, A.; Suprapto, N.; Putri, N. P.

    2018-03-01

    The performance assessment of basic physics experiment among undergraduate physics students which includes three stages: pre-laboratory, conducting experiment and final report was explored in this study. The research used a descriptive quantitative approach by utilizing guidebook of basic physics experiment. The findings showed that (1) the performance of pre-laboratory rate among undergraduate physics students in good category (average score = 77.55), which includes the ability of undergraduate physics students’ theory before they were doing the experiment. (2) The performance of conducting experiment was in good category (average score = 78.33). (3) While the performance of final report was in moderate category (average score = 73.73), with the biggest weakness at how to analyse and to discuss the data and writing the abstract.

  18. Quality Indicators in Laboratory Medicine: the status of the progress of IFCC Working Group "Laboratory Errors and Patient Safety" project.

    PubMed

    Sciacovelli, Laura; Lippi, Giuseppe; Sumarac, Zorica; West, Jamie; Garcia Del Pino Castro, Isabel; Furtado Vieira, Keila; Ivanov, Agnes; Plebani, Mario

    2017-03-01

    The knowledge of error rates is essential in all clinical laboratories as it enables them to accurately identify their risk level, and compare it with those of other laboratories in order to evaluate their performance in relation to the State-of-the-Art (i.e. benchmarking) and define priorities for improvement actions. Although no activity is risk free, it is widely accepted that the risk of error is minimized by the use of Quality Indicators (QIs) managed as a part of laboratory improvement strategy and proven to be suitable monitoring and improvement tools. The purpose of QIs is to keep the error risk at a level that minimizes the likelihood of patients. However, identifying a suitable State-of-the-Art is challenging, because it calls for the knowledge of error rates measured in a variety of laboratories throughout world that differ in their organization and management, context, and the population they serve. Moreover, it also depends on the choice of the events to keep under control and the individual procedure for measurement. Although many laboratory professionals believe that the systemic use of QIs in Laboratory Medicine may be effective in decreasing errors occurring throughout the total testing process (TTP), to improve patient safety as well as to satisfy the requirements of International Standard ISO 15189, they find it difficult to maintain standardized and systematic data collection, and to promote continued high level of interest, commitment and dedication in the entire staff. Although many laboratories worldwide express a willingness to participate to the Model of QIs (MQI) project of IFCC Working Group "Laboratory Errors and Patient Safety", few systematically enter/record their own results and/or use a number of QIs designed to cover all phases of the TTP. Many laboratories justify their inadequate participation in data collection of QIs by claiming that the number of QIs included in the MQI is excessive. However, an analysis of results suggests

  19. Estimating Implementation and Operational Costs of an Integrated Tiered CD4 Service including Laboratory and Point of Care Testing in a Remote Health District in South Africa

    PubMed Central

    Cassim, Naseem; Coetzee, Lindi M.; Schnippel, Kathryn; Glencross, Deborah K.

    2014-01-01

    Background An integrated tiered service delivery model (ITSDM) has been proposed to provide ‘full-coverage’ of CD4 services throughout South Africa. Five tiers are described, defined by testing volumes and number of referring health-facilities. These include: (1) Tier-1/decentralized point-of-care service (POC) in a single site; Tier-2/POC-hub servicing processing <30–40 samples from 8–10 health-clinics; Tier-3/Community laboratories servicing ∼50 health-clinics, processing <150 samples/day; high-volume centralized laboratories (Tier-4 and Tier-5) processing <300 or >600 samples/day and serving >100 or >200 health-clinics, respectively. The objective of this study was to establish costs of existing and ITSDM-tiers 1, 2 and 3 in a remote, under-serviced district in South Africa. Methods Historical health-facility workload volumes from the Pixley-ka-Seme district, and the total volumes of CD4 tests performed by the adjacent district referral CD4 laboratories, linked to locations of all referring clinics and related laboratory-to-result turn-around time (LTR-TAT) data, were extracted from the NHLS Corporate-Data-Warehouse for the period April-2012 to March-2013. Tiers were costed separately (as a cost-per-result) including equipment, staffing, reagents and test consumable costs. A one-way sensitivity analyses provided for changes in reagent price, test volumes and personnel time. Results The lowest cost-per-result was noted for the existing laboratory-based Tiers- 4 and 5 ($6.24 and $5.37 respectively), but with related increased LTR-TAT of >24–48 hours. Full service coverage with TAT <6-hours could be achieved with placement of twenty-seven Tier-1/POC or eight Tier-2/POC-hubs, at a cost-per-result of $32.32 and $15.88 respectively. A single district Tier-3 laboratory also ensured ‘full service coverage’ and <24 hour LTR-TAT for the district at $7.42 per-test. Conclusion Implementing a single Tier-3/community laboratory to extend and improve delivery

  20. Spontaneous Findings in the Eyes of Cynomolgus Monkeys ( Macaca fascicularis) of Mauritian Origin.

    PubMed

    Woicke, Jochen; Haile, Solomon; Mysore, Jagannatha; Peden, W Michael; Lejeune, Typhaine; Sanderson, Thomas; Brodie, Thomas

    2018-04-01

    Spontaneous findings noted in the eyes of Mauritian cynomolgus monkeys are described and descriptions are supplemented with illustrations. Findings observed after extensive histopathologic examinations (20 to 44 sections per eye) from 20 control, 17 treatment-naive stock monkeys, and 2 findings noted in drug-treated monkeys that were considered to be spontaneous are included. Also included are findings from 361 control monkeys of routine toxicity studies performed at our laboratories, for most of which a standard histopathological examination of 1 section per eye was conducted. Common observations in monkeys examined extensively and in historical controls were limited to lymphocytic or mononuclear cell infiltrations of the uvea and/or conjunctiva/sclera and, less commonly observed, melanocytoma of the ciliary body or iris. Findings noted only in monkeys examined extensively consisted of inflammation of the conjunctiva, ora serrata cysts, glial nodules, focal degeneration of the retina, cystoid degeneration of the central retina, ballooning degeneration of the ciliary epithelium, cyst of the ciliary body, and decreased pigmentation of the retinal pigment epithelium. Changes recorded only in historical controls included retinal atrophy and nuclear displacement in the retina. Lesions are discussed and compared with pertinent literature.

  1. Aerobic vaginitis and mixed infections: comparison of clinical and laboratory findings.

    PubMed

    Fan, Aiping; Yue, Yingli; Geng, Nv; Zhang, Huiying; Wang, Yingmei; Xue, Fengxia

    2013-02-01

    To investigate the clinical features of aerobic vaginitis (AV) and mixed infections with AV to achieve efficient diagnosis. From April 2008 to August 2009, 657 consecutive outpatients with vaginal symptoms in gynecology clinic in the General Hospital of Tianjin Medical University were investigated. Samples were taken for examination of vaginal discharge and fresh wet mount microscopy. AV, bacterial vaginosis (BV), vulvovaginal candidiasis (VVC), and trichomonal vaginitis (TV) were diagnosed according to standardized definitions. Sixty patients with single AV were randomly selected over the same period. Each patient accepted moxifloxacin therapy. Two kinds of treatment course (400 mg qd, 6 days or 400 mg qd, 12 days) were given. Clinical features and laboratory test results in the first visit and follow-ups were recorded and statistically analyzed. Among the 657 cases, AV was found in 23.74 % of the cases (156/657). AV mixed infections were diagnosed in 53.85 % (84/156): the mixed infections included VVC (32/84, 38.10 %), BV (31/84, 36.90 %), and TV (21/84, 25.00 %). Common symptoms of AV were a change in the characteristics of the discharge (44/72, 61.11 %) and increased discharge (30/72, 41.67 %). Vaginal pH was usually higher than 4.5 (63/72, 87.50 %). Enterococcus faecalis, Streptococcus viridans, Escherichia coli, and Staphylococcus epidermidis were frequently isolated. There is no statistically significant difference between two moxifloxacin treatment groups (p > 0.05). Cure rate was 89.7 % in 6-day group, and 71.4 % in 12-day group. AV is a common vaginal infection, and it is often mixed with other infections, especially VVC, BV and TV. The symptoms and signs of AV mixed infections are atypical. If a patient has vaginal complaints, it is necessary to determine whether AV or mixed infections are present. Oral moxifloxacin is effective in treating AV, and an appropriate course should be selected taking the severity of AV into consideration.

  2. Ab Initio Determinations of Photoelectron Spectra Including Vibronic Features: An Upper-Level Undergraduate Physical Chemistry Laboratory

    ERIC Educational Resources Information Center

    Lord, Richard L.; Davis, Lisa; Millam, Evan L.; Brown, Eric; Offerman, Chad; Wray, Paul; Green, Susan M. E.

    2008-01-01

    We present a first-principles determination of the photoelectron spectra of water and hypochlorous acid as a laboratory exercise accessible to students in an undergraduate physical chemistry course. This paper demonstrates the robustness and user-friendliness of software developed for the Franck-Condon factor calculation. While the calculator is…

  3. Medical Laboratory Assistant. Laboratory Occupations Cluster.

    ERIC Educational Resources Information Center

    Michigan State Univ., East Lansing. Coll. of Agriculture and Natural Resources Education Inst.

    This task-based curriculum guide for medical laboratory assistant is intended to help the teacher develop a classroom management system where students learn by doing. Introductory materials include a Dictionary of Occupational Titles job code and title sheet, a career ladder, a matrix relating duty/task numbers to job titles, and a task list. Each…

  4. Assessment of laboratory logistics management information system practice for HIV/AIDS and tuberculosis laboratory commodities in selected public health facilities in Addis Ababa, Ethiopia.

    PubMed

    Desale, Adino; Taye, Bineyam; Belay, Getachew; Nigatu, Alemayehu

    2013-01-01

    Logistics management information system for health commodities remained poorly implemented in most of developing countries. To assess the status of laboratory logistics management information system for HIV/AIDS and tuberculosis laboratory commodities in public health facilities in Addis Ababa. A cross-sectional descriptive study was conducted from September 2010-January 2011 at selected public health facilities. A stratified random sampling method was used to include a total of 43 facilities which, were investigated through quantitative methods using structured questionnaires interviews. Focus group discussion with the designated supply chain managers and key informant interviews were conducted for the qualitative method. There exists a well-designed logistics system for laboratory commodities with trained pharmacy personnel, distributed standard LMIS formats and established inventory control procedures. However, majority of laboratory professionals were not trained in LMIS. Majority of the facilities (60.5%) were stocked out for at least one ART monitoring and TB laboratory reagents and the highest stock out rate was for chemistry reagents. Expired ART monitoring laboratory commodities were found in 25 (73.5%) of facilities. Fifty percent (50%) of the assessed hospitals and 54% of health centers were currently using stock/bin cards for all HIV/AIDS and TB laboratory commodities in main pharmacy store, among these only 25% and 20.8% of them were updated with accurate information matching with the physical count done at the time of visit for hospitals and health centers respectively. Even though there exists a well designed laboratory LMIS, keeping quality stock/bin cards and LMIS reports were very low. Key ART monitoring laboratory commodities were stock out at many facilities at the day of visit and during the past six months. Based on findings, training of laboratory personnel's managing laboratory commodities and keeping accurate inventory control procedures

  5. Assessment of laboratory logistics management information system practice for HIV/AIDS and tuberculosis laboratory commodities in selected public health facilities in Addis Ababa, Ethiopia

    PubMed Central

    Desale, Adino; Taye, Bineyam; Belay, Getachew; Nigatu, Alemayehu

    2013-01-01

    Introduction Logistics management information system for health commodities remained poorly implemented in most of developing countries. To assess the status of laboratory logistics management information system for HIV/AIDS and tuberculosis laboratory commodities in public health facilities in Addis Ababa. Methods A cross-sectional descriptive study was conducted from September 2010-January 2011 at selected public health facilities. A stratified random sampling method was used to include a total of 43 facilities which, were investigated through quantitative methods using structured questionnaires interviews. Focus group discussion with the designated supply chain managers and key informant interviews were conducted for the qualitative method. Results There exists a well-designed logistics system for laboratory commodities with trained pharmacy personnel, distributed standard LMIS formats and established inventory control procedures. However, majority of laboratory professionals were not trained in LMIS. Majority of the facilities (60.5%) were stocked out for at least one ART monitoring and TB laboratory reagents and the highest stock out rate was for chemistry reagents. Expired ART monitoring laboratory commodities were found in 25 (73.5%) of facilities. Fifty percent (50%) of the assessed hospitals and 54% of health centers were currently using stock/bin cards for all HIV/AIDS and TB laboratory commodities in main pharmacy store, among these only 25% and 20.8% of them were updated with accurate information matching with the physical count done at the time of visit for hospitals and health centers respectively. Conclusion Even though there exists a well designed laboratory LMIS, keeping quality stock/bin cards and LMIS reports were very low. Key ART monitoring laboratory commodities were stock out at many facilities at the day of visit and during the past six months. Based on findings, training of laboratory personnel's managing laboratory commodities and keeping

  6. Cold Agglutinin Disease; A Laboratory Challenge.

    PubMed

    Nikousefat, Zahra; Javdani, Moosa; Hashemnia, Mohammad; Haratyan, Abbas; Jalili, Ali

    2015-10-01

    Autoimmune haemolytic anemia (AIHA) is a complex process characterized by an immune reaction against red blood cell self-antigens. The analysis of specimens, drawn from patients with cold auto-immune hemolytic anemia is a difficult problem for automated hematology analyzer. This paper was written to alert technologists and pathologists to the presence of cold agglutinins and its effect on laboratory tests. A 72-year-old female presented to the Shafa laboratory for hematology profile evaluation. CBC indices showed invalid findings with the Sysmex automated hematology analyzer. Checking the laboratory process showed precipitation residue sticking to the sides of the tube. After warming the tubes, results become valid and the problem attributed to cold agglutinin disease. In this situation, aggregation of RBCs, which occurs at t < 30°C, causes invalid findings meanwhile working with automated hematology analyzer. Knowledge of this phenomenon can help prevent wasting too much time and make an early and accurate diagnosis.

  7. Corrective Action Plan in response to the March 1992 Tiger Team Assessment of the Ames Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-11-20

    On March 5, 1992, a Department of Energy (DOE) Tiger Team completed an assessment of the Ames Laboratory, located in Ames, Iowa. The purpose of the assessment was to provide the Secretary of Energy with a report on the status and performance of Environment, Safety and Health (ES H) programs at Ames Laboratory. Detailed findings of the assessment are presented in the report, DOE/EH-0237, Tiger Team Assessment of the Ames Laboratory. This document, the Ames Laboratory Corrective Action Plan (ALCAP), presents corrective actions to overcome deficiencies cited in the Tiger Team Assessment. The Tiger Team identified 53 Environmental findings, frommore » which the Team derived four key findings. In the Safety and Health (S H) area, 126 concerns were identified, eight of which were designated Category 11 (there were no Category I concerns). Seven key concerns were derived from the 126 concerns. The Management Subteam developed 19 findings which have been summarized in four key findings. The eight S H Category 11 concerns identified in the Tiger Team Assessment were given prompt management attention. Actions to address these deficiencies have been described in individual corrective action plans, which were submitted to DOE Headquarters on March 20, 1992. The ALCAP includes actions described in this early response, as well as a long term strategy and framework for correcting all remaining deficiencies. Accordingly, the ALCAP presents the organizational structure, management systems, and specific responses that are being developed to implement corrective actions and to resolve root causes identified in the Tiger Team Assessment. The Chicago Field Office (CH), IowaState University (ISU), the Institute for Physical Research and Technology (IPRT), and Ames Laboratory prepared the ALCAP with input from the DOE Headquarters, Office of Energy Research (ER).« less

  8. Corrective Action Plan in response to the March 1992 Tiger Team Assessment of the Ames Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-11-20

    On March 5, 1992, a Department of Energy (DOE) Tiger Team completed an assessment of the Ames Laboratory, located in Ames, Iowa. The purpose of the assessment was to provide the Secretary of Energy with a report on the status and performance of Environment, Safety and Health (ES&H) programs at Ames Laboratory. Detailed findings of the assessment are presented in the report, DOE/EH-0237, Tiger Team Assessment of the Ames Laboratory. This document, the Ames Laboratory Corrective Action Plan (ALCAP), presents corrective actions to overcome deficiencies cited in the Tiger Team Assessment. The Tiger Team identified 53 Environmental findings, from whichmore » the Team derived four key findings. In the Safety and Health (S&H) area, 126 concerns were identified, eight of which were designated Category 11 (there were no Category I concerns). Seven key concerns were derived from the 126 concerns. The Management Subteam developed 19 findings which have been summarized in four key findings. The eight S&H Category 11 concerns identified in the Tiger Team Assessment were given prompt management attention. Actions to address these deficiencies have been described in individual corrective action plans, which were submitted to DOE Headquarters on March 20, 1992. The ALCAP includes actions described in this early response, as well as a long term strategy and framework for correcting all remaining deficiencies. Accordingly, the ALCAP presents the organizational structure, management systems, and specific responses that are being developed to implement corrective actions and to resolve root causes identified in the Tiger Team Assessment. The Chicago Field Office (CH), IowaState University (ISU), the Institute for Physical Research and Technology (IPRT), and Ames Laboratory prepared the ALCAP with input from the DOE Headquarters, Office of Energy Research (ER).« less

  9. National Laboratory Planning: Developing Sustainable Biocontainment Laboratories in Limited Resource Areas.

    PubMed

    Yeh, Kenneth B; Adams, Martin; Stamper, Paul D; Dasgupta, Debanjana; Hewson, Roger; Buck, Charles D; Richards, Allen L; Hay, John

    2016-01-01

    Strategic laboratory planning in limited resource areas is essential for addressing global health security issues. Establishing a national reference laboratory, especially one with BSL-3 or -4 biocontainment facilities, requires a heavy investment of resources, a multisectoral approach, and commitments from multiple stakeholders. We make the case for donor organizations and recipient partners to develop a comprehensive laboratory operations roadmap that addresses factors such as mission and roles, engaging national and political support, securing financial support, defining stakeholder involvement, fostering partnerships, and building trust. Successful development occurred with projects in African countries and in Azerbaijan, where strong leadership and a clear management framework have been key to success. A clearly identified and agreed management framework facilitate identifying the responsibility for developing laboratory capabilities and support services, including biosafety and biosecurity, quality assurance, equipment maintenance, supply chain establishment, staff certification and training, retention of human resources, and sustainable operating revenue. These capabilities and support services pose rate-limiting yet necessary challenges. Laboratory capabilities depend on mission and role, as determined by all stakeholders, and demonstrate the need for relevant metrics to monitor the success of the laboratory, including support for internal and external audits. Our analysis concludes that alternative frameworks for success exist for developing and implementing capabilities at regional and national levels in limited resource areas. Thus, achieving a balance for standardizing practices between local procedures and accepted international standards is a prerequisite for integrating new facilities into a country's existing public health infrastructure and into the overall international scientific community.

  10. National Laboratory Planning: Developing Sustainable Biocontainment Laboratories in Limited Resource Areas

    PubMed Central

    Adams, Martin; Stamper, Paul D.; Dasgupta, Debanjana; Hewson, Roger; Buck, Charles D.; Richards, Allen L.; Hay, John

    2016-01-01

    Strategic laboratory planning in limited resource areas is essential for addressing global health security issues. Establishing a national reference laboratory, especially one with BSL-3 or -4 biocontainment facilities, requires a heavy investment of resources, a multisectoral approach, and commitments from multiple stakeholders. We make the case for donor organizations and recipient partners to develop a comprehensive laboratory operations roadmap that addresses factors such as mission and roles, engaging national and political support, securing financial support, defining stakeholder involvement, fostering partnerships, and building trust. Successful development occurred with projects in African countries and in Azerbaijan, where strong leadership and a clear management framework have been key to success. A clearly identified and agreed management framework facilitate identifying the responsibility for developing laboratory capabilities and support services, including biosafety and biosecurity, quality assurance, equipment maintenance, supply chain establishment, staff certification and training, retention of human resources, and sustainable operating revenue. These capabilities and support services pose rate-limiting yet necessary challenges. Laboratory capabilities depend on mission and role, as determined by all stakeholders, and demonstrate the need for relevant metrics to monitor the success of the laboratory, including support for internal and external audits. Our analysis concludes that alternative frameworks for success exist for developing and implementing capabilities at regional and national levels in limited resource areas. Thus, achieving a balance for standardizing practices between local procedures and accepted international standards is a prerequisite for integrating new facilities into a country's existing public health infrastructure and into the overall international scientific community. PMID:27559843

  11. Including Non-Traditional Instrumentation in Undergraduate Environmental Chemistry Courses

    ERIC Educational Resources Information Center

    Jenkins, J. David; Orvis, Jessica N.; Smith, C. Jimmy; Manley, Citabria; Rice, Jeanette K. 2

    2004-01-01

    Non-traditional instrumentation was obtained for Georgia Southern undergraduates to attain fundamental environmental education through unique laboratory experiences. In this context, the method for including a direct mercury analyzer into both major and non-major environmental laboratories is reported.

  12. Eye protection in dental laboratories.

    PubMed

    Palenik, C J

    1997-09-01

    Many dental laboratory procedures increase the chances of serious eye injury. This would include traumatic injuries due to projectiles or through exposure to harsh chemicals or heat and infections from contact with patient body fluids. To help assure a safer working environment, awareness of the need for eye protection must be established and maintained by all laboratory personnel. The purpose of this article are: 1) to list the applicable federal regulations concerning eye safety in dental laboratory workplaces; 2) to describe the various types of appropriate eyewear; and 3) to identify which protective devices best prevent exposure to specific types of hazards. The goal of this article is to help dental laboratories with their employee safety programs, especially concerning the selection of protective eyewear. Such programs must include engineering controls and work practice controls plus appropriate personal protective equipment. Laboratories today must comply with safety mandates in the most effective and efficient manner.

  13. Measuring meaningful learning in the undergraduate chemistry laboratory

    NASA Astrophysics Data System (ADS)

    Galloway, Kelli R.

    The undergraduate chemistry laboratory has been an essential component in chemistry education for over a century. The literature includes reports on investigations of singular aspects laboratory learning and attempts to measure the efficacy of reformed laboratory curriculum as well as faculty goals for laboratory learning which found common goals among instructors for students to learn laboratory skills, techniques, experimental design, and to develop critical thinking skills. These findings are important for improving teaching and learning in the undergraduate chemistry laboratory, but research is needed to connect the faculty goals to student perceptions. This study was designed to explore students' ideas about learning in the undergraduate chemistry laboratory. Novak's Theory of Meaningful Learning was used as a guide for the data collection and analysis choices for this research. Novak's theory states that in order for meaningful learning to occur the cognitive, affective, and psychomotor domains must be integrated. The psychomotor domain is inherent in the chemistry laboratory, but the extent to which the cognitive and affective domains are integrated is unknown. For meaningful learning to occur in the laboratory, students must actively integrate both the cognitive domain and the affective domains into the "doing" of their laboratory work. The Meaningful Learning in the Laboratory Instrument (MLLI) was designed to measure students' cognitive and affective expectations and experiences within the context of conducting experiments in the undergraduate chemistry laboratory. Evidence for the validity and reliability of the data generated by the MLLI were collected from multiple quantitative studies: a one semester study at one university, a one semester study at 15 colleges and universities across the United States, and a longitudinal study where the MLLI was administered 6 times during two years of general and organic chemistry laboratory courses. Results from

  14. Introducing Laboratory Safety.

    ERIC Educational Resources Information Center

    DeLorenzo, Ronald

    1985-01-01

    Presents a simple, 10-item quiz designed to make students aware that they must learn laboratory safety. The items include questions on acid/base accidents, several types of fire extinguishers, and safety glassses. Answers and some explanations are included. (DH)

  15. 21 CFR 226.58 - Laboratory controls.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Laboratory controls. Laboratory controls shall include the establishment of adequate specifications and test... establishment of master records containing appropriate specifications and a description of the test procedures... necessary laboratory test procedures to check such specifications. (c) Assays which shall be made of...

  16. Laboratory Investigation of Astrophysical Collimated Jets with Intense Lasers

    NASA Astrophysics Data System (ADS)

    Yuan, Dawei; Li, Yutong; Tao, Tao; Wei, Huigang; Zhong, Jiayong; Zhu, Baojun; Li, Yanfei; Zhao, Jiarui; Li, Fang; Han, Bo; Zhang, Zhe; Liang, Guiyun; Wang, Feilu; Hu, Guangyue; Zheng, Jian; Jiang, Shaoen; Du, Kai; Ding, Yongkun; Zhou, Shenlei; Zhu, Baoqiang; Zhu, Jianqiang; Zhao, Gang; Zhang, Jie

    2018-06-01

    One of the remarkable dynamic features of the Herbig–Haro (HH) object is its highly collimated propagation far away from the accretion disk. Different factors are proposed to give us a clearly physical explanation behind these fascinating phenomena, including magnetic field, radiation cooling, surrounding medium, and so on. Laboratory astrophysics, as a new complementary method of studying astrophysical issues, can provide an insight into these behaviors in a similar and controllable laboratory environment. Here we report the scaled laboratory experiments that a well-collimated radiative jet with high Mach number is successfully created to mimic the evolution of HH objects. According to our results, we find that the radiation cooling effect within the jet and the outer rare surrounding plasmas from the X-ray (>keV) photoionized target contribute to the jet collimation. The local nonuniform density structures along the collimated radiative jet axis are caused by the pressure competition between the inner jet and the outer plasmas. The corresponding simulations performed with radiation-hydrodynamic codes FLASH reveal how the radiative jet evolves.

  17. Multimodal Retinal Imaging in Incontinentia Pigmenti Including Optical Coherence Tomography Angiography: Findings From an Older Cohort With Mild Phenotype.

    PubMed

    Liu, Tin Yan Alvin; Han, Ian C; Goldberg, Morton F; Linz, Marguerite O; Chen, Connie J; Scott, Adrienne W

    2018-05-01

    Incontinentia pigmenti (IP) is a rare, X-linked dominant disease with potentially severe ocular complications that predominantly affect the peripheral retina. However, little is known about its effects on the macula. To describe the structural and vascular abnormalities observed in the maculas of patients with IP and to correlate these findings with peripheral pathologies. Prospective, cross-sectional study at Wilmer Eye Institute, Johns Hopkins University. Five participants with a clinical diagnosis of IP were included and underwent multimodal imaging with ultra-wide-field fluorescein angiography (FA), spectral-domain optical coherence tomography (OCT), and OCT angiography. The structural and vascular abnormalities observed on spectral-domain OCT and OCT angiography and their correlation with peripheral pathologies seen on ultra-wide-field FA. A total of 9 eyes from 5 patients (median age, 20.5 years; range, 8.4-54.2 years) were included. Median Snellen visual acuity was 20/32 (range, 20/16 to 20/63). ultra-wide-field FA-identified retinal vascular abnormalities in all 7 eyes in which FA was obtained. These abnormalities included microaneurysms, areas of nonperfusion, and vascular anastomoses, most of which were peripheral to the standard view of 30° FA with peripheral sweeps. Structural abnormalities were observed in 6 eyes on spectral-domain OCT, including inner retinal thinning and irregularities in the outer plexiform layer. Optical coherence tomography angiography abnormalities were noted in all 9 eyes, including decreased vascular density, abnormal vascular loops, and flow loss in the superficial and deep plexuses, which corresponded to areas of retinal thinning on spectral-domain OCT. Although our study is limited by the small sample size, the findings suggest that multimodal imaging is useful for detecting structural and vascular abnormalities that may not be apparent on ophthalmoscopy in patients with IP. Macular pathologies, especially a decrease in

  18. Post-Baccalaureate Laboratory Specialist Certifications and Master’s Degrees in Laboratory Medicine

    PubMed Central

    Johnson, Susan T.

    2013-01-01

    Opportunities to advance one’s knowledge and position are available within the clinical laboratory arena. By obtaining a specialist credential in chemistry, hematology or microbiology, a laboratorian has demonstrated advance knowledge and ability in their respective discipline. These specialist certifications open doors within and outside the laboratory profession and may lead to promotion. The specialist in blood banking credential is unique in that accredited training programs are available, some of which are affiliated with universities and graduate credit is granted for program completion. Other avenues available include pathologist assistants programs, diplomats in laboratory management and Master of Science degrees in clinical laboratory science. There are a number of choices available to achieve your professional goal. PMID:27683434

  19. Dehydration of 2-Methyl-1-Cyclohexanol: New Findings from a Popular Undergraduate Laboratory Experiment

    ERIC Educational Resources Information Center

    Friesen, J. Brent; Schretzman, Robert

    2011-01-01

    The mineral acid-catalyzed dehydration of 2-methyl-1-cyclohexanol has been a popular laboratory exercise in second-year organic chemistry for several decades. The dehydration experiment is often performed by organic chemistry students to illustrate Zaitsev's rule. However, sensitive analytical techniques reveal that the results do not entirely…

  20. ORNL (Oak Ridge National Laboratory) 89

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, T.D.; Appleton, B.R.; Jefferson, J.W.

    This is the inaugural issues of an annual publication about the Oak Ridge National Laboratory. Here you will find a brief overview of ORNL, a sampling of our recent research achievements, and a glimpse of the directions we want to take over the next 15 years. A major purpose of ornl 89 is to provide the staff with a sketch of the character and dynamics of the Laboratory.

  1. How well do general practitioners manage laboratory test results for patients with diabetes mellitus and cardiovascular disease?: A systematic review.

    PubMed

    McCaughey, Euan J; Li, Julie; Badrick, Tony C; Westbrook, Johanna I; Georgiou, Andrew

    2017-10-01

    To evaluate how well general practitioners (GPs) manage and respond to laboratory results for patients with diabetes mellitus (DM) and cardiovascular disease (CVD). MEDLINE, CINAHL, Embase, EBM reviews, ProQuest and Scopus. Peer-reviewed journal articles published between 2000 and 2015 that assessed GPs' management of laboratory results for patients with DM or CVD. Study design and demographics, laboratory tests and key findings relating to GP management of laboratory results were extracted from studies. Thirteen articles were included, comprising seven studies which utilized surveys, four observational studies, one cohort study and one randomized controlled trial. Findings indicate that GPs often overestimate the risk of complications associated with DM and CVD based on laboratory results and have unrealistically high expectations regarding the precision of laboratory tests. Considerable variation existed in the use of repeat testing for diagnostic confirmation and in GPs' identification of the difference between two consecutive results required to indicate a change in patient condition. GPs also often failed to initiate appropriate treatment for patients with DM and CVD based on laboratory results. Feedback to GPs about their test ordering patterns and educational messages on laboratory results improved clinical outcomes. Evidence about how well GPs manage results and its impact on patient outcomes remains weak and inconclusive. This review identified a number of areas where interventions could support GPs to improve the interpretation and management of laboratory test results, including feedback to GPs and educational messages on test result reports. © The Author 2017. Published by Oxford University Press in association with the International Society for Quality in Health Care. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  2. Laboratory and software applications for clinical trials: the global laboratory environment.

    PubMed

    Briscoe, Chad

    2011-11-01

    The Applied Pharmaceutical Software Meeting is held annually. It is sponsored by The Boston Society, a not-for-profit organization that coordinates a series of meetings within the global pharmaceutical industry. The meeting generally focuses on laboratory applications, but in recent years has expanded to include some software applications for clinical trials. The 2011 meeting emphasized the global laboratory environment. Global clinical trials generate massive amounts of data in many locations that must be centralized and processed for efficient analysis. Thus, the meeting had a strong focus on establishing networks and systems for dealing with the computer infrastructure to support such environments. In addition to the globally installed laboratory information management system, electronic laboratory notebook and other traditional laboratory applications, cloud computing is quickly becoming the answer to provide efficient, inexpensive options for managing the large volumes of data and computing power, and thus it served as a central theme for the meeting.

  3. Solar Radiation Research Laboratory | Energy Systems Integration Facility |

    Science.gov Websites

    radiation components, and has expanded its expertise to include integrated metrology, optics, electronics Acquisition Laboratory, Metrology Laboratory, Optics Laboratory, and Electronics Laboratory. Photo of a

  4. Undergraduate Organic Chemistry Laboratory Safety

    NASA Astrophysics Data System (ADS)

    Luckenbaugh, Raymond W.

    1996-11-01

    Each organic chemistry student should become familiar with the educational and governmental laboratory safety requirements. One method for teaching laboratory safety is to assign each student to locate safety resources for a specific class laboratory experiment. The student should obtain toxicity and hazardous information for all chemicals used or produced during the assigned experiment. For example, what is the LD50 or LC50 for each chemical? Are there any specific hazards for these chemicals, carcinogen, mutagen, teratogen, neurotixin, chronic toxin, corrosive, flammable, or explosive agent? The school's "Chemical Hygiene Plan", "Prudent Practices for Handling Hazardous Chemicals in the Laboratory" (National Academy Press), and "Laboratory Standards, Part 1910 - Occupational Safety and Health Standards" (Fed. Register 1/31/90, 55, 3227-3335) should be reviewed for laboratory safety requirements for the assigned experiment. For example, what are the procedures for safe handling of vacuum systems, if a vacuum distillation is used in the assigned experiment? The literature survey must be submitted to the laboratory instructor one week prior to the laboratory session for review and approval. The student should then give a short presentation to the class on the chemicals' toxicity and hazards and describe the safety precautions that must be followed. This procedure gives the student first-hand knowledge on how to find and evaluate information to meet laboartory safety requirements.

  5. Developing laboratory networks: a practical guide and application.

    PubMed

    Kirk, Carol J; Shult, Peter A

    2010-01-01

    The role of the public health laboratory (PHL) in support of public health response has expanded beyond testing to include a number of other core functions, such as emergency response, training and outreach, communications, laboratory-based surveillance, and laboratory data management. These functions can only be accomplished by a network that includes public health and other agency laboratories and clinical laboratories. It is a primary responsibility of the PHL to develop and maintain such a network. In this article, we present practical recommendations-based on 17 years of network development experience-for the development of statewide laboratory networks. These recommendations, and examples of current laboratory networks, are provided to facilitate laboratory network development in other states. The development of laboratory networks will enhance each state's public health system and is critical to the development of a robust national Laboratory Response Network.

  6. 75 FR 24703 - Findings of Misconduct in Science

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Office of the Secretary Findings of Misconduct in Science... of HHS, issued a final notice of debarment based on the misconduct in science findings of the Office... Retrovirology Pathogenesis Laboratory, UW, committed misconduct in science (scientific misconduct) in research...

  7. Use of a United States-based laboratory as a hematopathology reference center for a developing country: logistics and results.

    PubMed

    Deetz, C O; Scott, M G; Ladenson, J H; Seyoum, M; Hassan, A; Kreisel, F H; Nguyen, T T; Frater, J L

    2013-02-01

    With proper logistical support and sponsorship, a laboratory in an industrialized nation might be able to act as a reference laboratory for clinicians based in a developing country. We built on previous experience in the clinical laboratory to see whether a specialized histopathology service (hematopathology) could be provided to a developing country without the expertise or experience to do it in country. Over an 13-year period, 582 cases from 579 individuals were analyzed. Principal pathologic findings included acute leukemia in 84 cases (14%), dyspoiesis in one or more of the hematopoietic lineages in 65 cases (11%, including three cases with high-grade myelodysplasia), 23 cases (4%) with findings suspicious for a chronic myeloproliferative disorder, 35 cases (6%) with findings suspicious for a lymphoproliferative disorder, and infectious organisms (presumably Leishmania in most instances) in 9 (1%) of cases. Specimens from 45 cases (8%) were unsatisfactory owing to extreme hemodilution and/or specimen degeneration. With proper support, a medical laboratory in an industrialized nation may serve as a reference facility for a developing nation. The use of existing infrastructure may be remarkably effective to achieve optimal turnaround time. Although the lack of ancillary studies and follow-up biopsies limit the ability to achieve a definitive diagnosis in many cases, this must be viewed in the context of the limited ability to diagnose or manage hematopoietic neoplasia in developing nations. © 2012 Blackwell Publishing Ltd.

  8. [Postgraduates' training as laboratory physicians/clinical pathologists in Japan--board certification of JSLM as a mandatory requirement for chairpersons of laboratory medicine].

    PubMed

    Kumasaka, Kazunari

    2002-04-01

    The educational committee of the Japanese Society of Laboratory Medicine(JSLM) proposed a revised laboratory medicine residency curriculum in 1999 and again in 2001. The committee believes that present undergraduate clinical training is insufficient and that Japanese medical graduates need clinical training for two years after graduation. This two years training should be a precondition for further postgraduate training in laboratory medicine and should include fundamental clinical skills(communication skills, physical examination and common laboratory procedures such as Gram's stain, Wright-Giemsa stain and urinalysis). After the two years training, the minimal training period of laboratory medicine should be three years, and should include: 1) Principles, instrumentation and techniques of each discipline including clinical chemistry, clinical hematology, clinical microbiology, clinical immunology, blood banking and other specific areas. 2) The use of laboratory information in a medical setting. 3) Interaction of the laboratory physician with laboratory staff, physicians and patients. With good on-the-job training and 24 hours on-call duties, laboratory physicians are expected to perform their tasks, including laboratory management, effectively. They should have appropriate educational background and should be well motivated. The background and duties of the laboratory physicians often reflect the institutional needs and personal philosophy of the chairperson of their department. At the moment, few senior physicians in Japan have qualifications in laboratory medicine and are unable, therefore, to provide the necessary guidance to help the laboratory physicians in their work. I therefore believe that the board certification of JSLM should be regarded as mandatory for chairpersons of laboratory medicine. Our on-call service system can enhance the training in laboratory medicine, and improve not only laboratory quality assurance but patients' care as well.

  9. The Effect of Ivermectin in Seven Strains of Aedes aegypti (Diptera: Culicidae) Including a Genetically Diverse Laboratory Strain and Three Permethrin Resistant Strains

    PubMed Central

    Deus, K. M.; Saavedra-rodriguez, K.; Butters, M. P.; Black, W. C.; Foy, B. D.

    2014-01-01

    Seven different strains of Aedes aegypti (L.), including a genetically diverse laboratory strain, three laboratory-selected permethrin-resistant strains, a standard reference strain, and two recently colonized strains were fed on human blood containing various concentrations of ivermectin. Ivermectin reduced adult survival, fecundity, and hatch rate of eggs laid by ivermectin-treated adults in all seven strains. The LC50 of ivermectin for adults and the concentration that prevented 50% of eggs from hatching was calculated for all strains. Considerable variation in adult survival after an ivermectin-bloodmeal occurred among strains, and all three permethrin-resistant strains were significantly less susceptible to ivermectin than the standard reference strain. The hatch rate after an ivermectin bloodmeal was less variable among strains, and only one of the permethrin-resistant strains differed significantly from the standard reference strain. Our studies suggest that ivermectin induces adult mortality and decreases the hatch rate of eggs through different mechanisms. A correlation analysis of log-transformed LC50 among strains suggests that permethrin and ivermectin cross-resistance may occur. PMID:22493855

  10. MICROBIAL LABORATORY GUIDANCE MANUAL FOR THE ...

    EPA Pesticide Factsheets

    The Long-Term 2 Enhanced Surface Water Treatment Rule Laboratory Instruction Manual will be a compilation of all information needed by laboratories and field personnel to collect, analyze, and report the microbiological data required under the rule. The manual will provide laboratories with a single source of information that currently is available from various sources including the latest versions of Methods 1622 and 1623, including all approved, equivalent modifications; the procedures for E.coli methods approved for use under the LT2ESWTR; lists of vendor sources; data recording forms; data reporting requirements; information on the Laboratory Quality Assurance Evaluation Program for the Analysis of Cryptosporidium in Water; and sample collection procedures. Although most of this information is available elsewhere, a single, comprehensive compendium containing this information is needed to aid utilities and laboratories performing the sampling and analysis activities required under the LT2 rule. This manual will serve as an instruction manual for laboratories to use when collecting data for Crypto, E. coli and turbidity.

  11. The Laboratory for Terrestrial Physics

    NASA Technical Reports Server (NTRS)

    2003-01-01

    The Laboratory for Terrestrial Physics is dedicated to the advancement of knowledge in Earth and planetary science, by conducting innovative research using space technology. The Laboratory's mission and activities support the work and new initiatives at NASA's Goddard Space Flight Center (GSFC). The Laboratory's success contributes to the Earth Science Directorate as a national resource for studies of Earth from Space. The Laboratory is part of the Earth Science Directorate based at the GSFC in Greenbelt, MD. The Directorate itself is comprised of the Global Change Data Center (GCDC), the Space Data and Computing Division (SDCD), and four science Laboratories, including Laboratory for Terrestrial Physics, Laboratory for Atmospheres, and Laboratory for Hydrospheric Processes all in Greenbelt, MD. The fourth research organization, Goddard Institute for Space Studies (GISS), is in New York, NY. Relevant to NASA's Strategic Plan, the Laboratory ensures that all work undertaken and completed is within the vision of GSFC. The philosophy of the Laboratory is to balance the completion of near term goals, while building on the Laboratory's achievements as a foundation for the scientific challenges in the future.

  12. Unusual Laboratory Findings in a Case of Norwegian Scabies Provided a Clue to Diagnosis

    PubMed Central

    Wong, Samson S. Y.; Woo, Patrick C. Y.; Yuen, Kwok-yung

    2005-01-01

    The diagnosis of Norwegian scabies was missed for a year for an elderly long-term-care facility resident. Serpiginous tracks were noted on the surface of Sabouraud dextrose agar used for fungal culture of the skin scrapings. This unusual laboratory manifestation must alert clinical microbiologists to the possible diagnosis of scabies. PMID:15872307

  13. 21 CFR 226.58 - Laboratory controls.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 4 2012-04-01 2012-04-01 false Laboratory controls. 226.58 Section 226.58 Food...: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR TYPE A MEDICATED ARTICLES Product Quality Control § 226.58 Laboratory controls. Laboratory controls shall include the establishment of adequate specifications and test...

  14. 21 CFR 226.58 - Laboratory controls.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 4 2011-04-01 2011-04-01 false Laboratory controls. 226.58 Section 226.58 Food...: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR TYPE A MEDICATED ARTICLES Product Quality Control § 226.58 Laboratory controls. Laboratory controls shall include the establishment of adequate specifications and test...

  15. 21 CFR 226.58 - Laboratory controls.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 4 2013-04-01 2013-04-01 false Laboratory controls. 226.58 Section 226.58 Food...: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR TYPE A MEDICATED ARTICLES Product Quality Control § 226.58 Laboratory controls. Laboratory controls shall include the establishment of adequate specifications and test...

  16. Preservice laboratory education strengthening enhances sustainable laboratory workforce in Ethiopia

    PubMed Central

    2013-01-01

    Background There is a severe healthcare workforce shortage in sub Saharan Africa, which threatens achieving the Millennium Development Goals and attaining an AIDS-free generation. The strength of a healthcare system depends on the skills, competencies, values and availability of its workforce. A well-trained and competent laboratory technologist ensures accurate and reliable results for use in prevention, diagnosis, care and treatment of diseases. Methods An assessment of existing preservice education of five medical laboratory schools, followed by remedial intervention and monitoring was conducted. The remedial interventions included 1) standardizing curriculum and implementation; 2) training faculty staff on pedagogical methods and quality management systems; 3) providing teaching materials; and 4) procuring equipment for teaching laboratories to provide practical skills to complement didactic education. Results A total of 2,230 undergraduate students from the five universities benefitted from the standardized curriculum. University of Gondar accounted for 252 of 2,230 (11.3%) of the students, Addis Ababa University for 663 (29.7%), Jimma University for 649 (29.1%), Haramaya University for 429 (19.2%) and Hawassa University for 237 (10.6%) of the students. Together the universities graduated 388 and 312 laboratory technologists in 2010/2011 and 2011/2012 academic year, respectively. Practical hands-on training and experience with well-equipped laboratories enhanced and ensured skilled, confident and competent laboratory technologists upon graduation. Conclusions Strengthening preservice laboratory education is feasible in resource-limited settings, and emphasizing its merits (ample local capacity, country ownership and sustainability) provides a valuable source of competent laboratory technologists to relieve an overstretched healthcare system. PMID:24164781

  17. Revealing all: misleading self-disclosure rates in laboratory-based online research.

    PubMed

    Callaghan, Diana E; Graff, Martin G; Davies, Joanne

    2013-09-01

    Laboratory-based experiments in online self-disclosure research may be inadvertently compromising the accuracy of research findings by influencing some of the factors known to affect self-disclosure behavior. Disclosure-orientated interviews conducted with 42 participants in the laboratory and in nonlaboratory settings revealed significantly greater breadth of self-disclosure in laboratory interviews, with message length and intimacy of content also strongly related. These findings suggest that a contrived online setting with a researcher presence may stimulate motivation for greater self-disclosure than would occur naturally in an online environment of an individual's choice. The implications of these findings are that researchers should consider the importance of experimental context and motivation in self-disclosure research.

  18. Wiki Laboratory Notebooks: Supporting Student Learning in Collaborative Inquiry-Based Laboratory Experiments

    NASA Astrophysics Data System (ADS)

    Lawrie, Gwendolyn Angela; Grøndahl, Lisbeth; Boman, Simon; Andrews, Trish

    2016-06-01

    Recent examples of high-impact teaching practices in the undergraduate chemistry laboratory that include course-based undergraduate research experiences and inquiry-based experiments require new approaches to assessing individual student learning outcomes. Instructors require tools and strategies that can provide them with insight into individual student contributions to collaborative group/teamwork throughout the processes of experimental design, data analysis, display and communication of their outcomes in relation to their research question(s). Traditional assessments in the form of laboratory notebooks or experimental reports provide limited insight into the processes of collaborative inquiry-based activities. A wiki environment offers a collaborative domain that can potentially support collaborative laboratory processes and scientific record keeping. In this study, the effectiveness of the wiki in supporting laboratory learning and assessment has been evaluated through analysis of the content and histories for three consenting, participating groups of students. The conversational framework has been applied to map the relationships between the instructor, tutor, students and laboratory activities. Analytics that have been applied to the wiki platform include: character counts, page views, edits, timelines and the extent and nature of the contribution by each student to the wiki. Student perceptions of both the role and the impact of the wiki on their experiences and processes have also been collected. Evidence has emerged from this study that the wiki environment has enhanced co-construction of understanding of both the experimental process and subsequent communication of outcomes and data. A number of features are identified to support success in the use of the wiki platform for laboratory notebooks.

  19. A survey of current practices for genomic sequencing test interpretation and reporting processes in US laboratories.

    PubMed

    O'Daniel, Julianne M; McLaughlin, Heather M; Amendola, Laura M; Bale, Sherri J; Berg, Jonathan S; Bick, David; Bowling, Kevin M; Chao, Elizabeth C; Chung, Wendy K; Conlin, Laura K; Cooper, Gregory M; Das, Soma; Deignan, Joshua L; Dorschner, Michael O; Evans, James P; Ghazani, Arezou A; Goddard, Katrina A; Gornick, Michele; Farwell Hagman, Kelly D; Hambuch, Tina; Hegde, Madhuri; Hindorff, Lucia A; Holm, Ingrid A; Jarvik, Gail P; Knight Johnson, Amy; Mighion, Lindsey; Morra, Massimo; Plon, Sharon E; Punj, Sumit; Richards, C Sue; Santani, Avni; Shirts, Brian H; Spinner, Nancy B; Tang, Sha; Weck, Karen E; Wolf, Susan M; Yang, Yaping; Rehm, Heidi L

    2017-05-01

    While the diagnostic success of genomic sequencing expands, the complexity of this testing should not be overlooked. Numerous laboratory processes are required to support the identification, interpretation, and reporting of clinically significant variants. This study aimed to examine the workflow and reporting procedures among US laboratories to highlight shared practices and identify areas in need of standardization. Surveys and follow-up interviews were conducted with laboratories offering exome and/or genome sequencing to support a research program or for routine clinical services. The 73-item survey elicited multiple choice and free-text responses that were later clarified with phone interviews. Twenty-one laboratories participated. Practices highly concordant across all groups included consent documentation, multiperson case review, and enabling patient opt-out of incidental or secondary findings analysis. Noted divergence included use of phenotypic data to inform case analysis and interpretation and reporting of case-specific quality metrics and methods. Few laboratory policies detailed procedures for data reanalysis, data sharing, or patient access to data. This study provides an overview of practices and policies of experienced exome and genome sequencing laboratories. The results enable broader consideration of which practices are becoming standard approaches, where divergence remains, and areas of development in best practice guidelines that may be helpful.Genet Med advance online publication 03 Novemeber 2016.

  20. 21 CFR 225.158 - Laboratory assays.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 4 2011-04-01 2011-04-01 false Laboratory assays. 225.158 Section 225.158 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS... Laboratory assays. Where the results of laboratory assays of drug components, including assays by State feed...

  1. 21 CFR 225.158 - Laboratory assays.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Laboratory assays. 225.158 Section 225.158 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS... Laboratory assays. Where the results of laboratory assays of drug components, including assays by State feed...

  2. Remote RF Laboratory Requirements: Engineers' and Technicians' Perspective

    ERIC Educational Resources Information Center

    Cagiltay, Nergiz Ercil; Aydin, Elif Uray; Kara, Ali

    2007-01-01

    This study aims to find out requirements and needs to be fulfilled in developing remote Radio Frequency (RF) laboratory. Remote laboratories are newly emerging solutions for better supporting of e-learning platforms and for increasing their efficiency and effectiveness in technical education. By this way, modern universities aim to provide…

  3. Validation of a laboratory and hospital information system in a medical laboratory accredited according to ISO 15189.

    PubMed

    Biljak, Vanja Radisic; Ozvald, Ivan; Radeljak, Andrea; Majdenic, Kresimir; Lasic, Branka; Siftar, Zoran; Lovrencic, Marijana Vucic; Flegar-Mestric, Zlata

    2012-01-01

    The aim of the study was to present a protocol for laboratory information system (LIS) and hospital information system (HIS) validation at the Institute of Clinical Chemistry and Laboratory Medicine of the Merkur University Hospital, Zagreb, Croatia. Validity of data traceability was checked by entering all test requests for virtual patient into HIS/LIS and printing corresponding barcoded labels that provided laboratory analyzers with the information on requested tests. The original printouts of the test results from laboratory analyzer(s) were compared with the data obtained from LIS and entered into the provided template. Transfer of data from LIS to HIS was examined by requesting all tests in HIS and creating real data in a finding generated in LIS. Data obtained from LIS and HIS were entered into a corresponding template. The main outcome measure was the accuracy of transfer obtained from laboratory analyzers and results transferred from LIS and HIS expressed as percentage (%). The accuracy of data transfer from laboratory analyzers to LIS was 99.5% and of that from LIS to HIS 100%. We presented our established validation protocol for laboratory information system and demonstrated that a system meets its intended purpose.

  4. LANGUAGE LABORATORY RESEARCH STUDIES IN NEW YORK CITY HIGH SCHOOLS--A DISCUSSION OF THE PROGRAM AND THE FINDINGS.

    ERIC Educational Resources Information Center

    LORGE, SARAH W.

    TO INVESTIGATE THE EFFECTS OF THE LANGUAGE LABORATORY ON FOREIGN LANGUAGE LEARNING, THE BUREAU OF AUDIO-VISUAL INSTRUCTION OF NEW YORK CITY CONDUCTED EXPERIMENTS IN 1ST-, 2D-, AND 3D-YEAR HIGH SCHOOL CLASSES. THE FIRST EXPERIMENT, WHICH COMPARED CONVENTIONALLY TAUGHT CLASSES WITH GROUPS HAVING SOME LABORATORY TEACHING, SHOWED THAT GROUPS WITH…

  5. The Naval Health Research Center Respiratory Disease Laboratory.

    PubMed

    Ryan, M; Gray, G; Hawksworth, A; Malasig, M; Hudspeth, M; Poddar, S

    2000-07-01

    Concern about emerging and reemerging respiratory pathogens prompted the development of a respiratory disease reference laboratory at the Naval Health Research Center. Professionals working in this laboratory have instituted population-based surveillance for pathogens that affect military trainees and responded to threats of increased respiratory disease among high-risk military groups. Capabilities of this laboratory that are unique within the Department of Defense include adenovirus testing by viral shell culture and microneutralization serotyping, influenza culture and hemagglutination inhibition serotyping, and other special testing for Streptococcus pneumoniae, Streptococcus pyogenes, Mycoplasma pneumonia, and Chlamydia pneumoniae. Projected capabilities of this laboratory include more advanced testing for these pathogens and testing for other emerging pathogens, including Bordetella pertussis, Legionella pneumoniae, and Haemophilus influenzae type B. Such capabilities make the laboratory a valuable resource for military public health.

  6. The Microscale Inorganic Laboratory: Safety, Economy and Versatility.

    ERIC Educational Resources Information Center

    Szafran, Zvi; And Others

    1989-01-01

    Discussed are four major advantages to the use of microscale laboratories for teaching chemistry. Included are effects on waste generation, laboratory safety, reagent variety, and laboratory efficiency. (CW)

  7. Risk Factor Analysis for AKI Including Laboratory Indicators: a Nationwide Multicenter Study of Hospitalized Patients.

    PubMed

    Nie, Sasa; Feng, Zhe; Tang, Li; Wang, Xiaolong; He, Yani; Fang, Jingai; Li, Suhua; Yang, Yibin; Mao, Huijuan; Jiao, Jundong; Liu, Wenhu; Cao, Ning; Wang, Wenge; Sun, Jifeng; Shao, Fengmin; Li, Wenge; He, Qiang; Jiang, Hongli; Lin, Hongli; Fu, Ping; Zhang, Xinzhou; Liu, Yinghong; Wu, Yonggui; Xi, ChunSheng; Liang, Meng; Qu, Zhijie; Zhu, Jun; Wu, Guangli; Zheng, Yali; Na, Yu; Li, Ying; Li, Wei; Cai, Guangyan; Chen, Xiangmei

    2017-01-01

    Risk factor studies for acute kidney injury (AKI) in China are lacking, especially those regarding non-traditional risk factors, such as laboratory indicators. All adult patients admitted to 38 tertiary and 22 secondary hospitals in China in any one month between July and December 2014 were surveyed. AKI patients were screened according to the Kidney Disease: Improving Global Outcomes' definition of AKI. Logistic regression was used to analyze the risk factors for AKI, and Cox regression was used to analyze the risk of in-hospital mortality for AKI patients; additionally, a propensity score analysis was used to reconfirm the risk factors among laboratory indicators for mortality. The morbidity of AKI was 0.97%. Independent risk factors for AKI were advancing age, male gender, hypertension, and chronic kidney disease. All-cause mortality was 16.5%. The predictors of mortality in AKI patients were advancing age, tumor, higher uric acid level and increases in Acute Physiologic Assessment and Chronic Health Evaluation II and Sequential Organ Failure Assessment scores. The hazard ratio (HR) for mortality with uric acid levels > 9.1 mg/dl compared with ≤ 5.2 mg/dl was 1.78 (95% CI: 1.23 to 2.58) for the AKI patients as a group, and was 1.73 (95% CI: 1.24 to 2.42) for a propensity score-matched set. In addition to traditional risk factors, uric acid level is an independent predictor of all-cause mortality after AKI. © 2017 The Author(s). Published by S. Karger AG, Basel.

  8. Host-finding behaviour in the nematode Pristionchus pacificus.

    PubMed

    Brown, Federico D; D'Anna, Isabella; Sommer, Ralf J

    2011-11-07

    Costs and benefits of foraging have been studied in predatory animals. In nematodes, ambushing or cruising behaviours represent adaptations that optimize foraging strategies for survival and host finding. A behaviour associated with host finding of ambushing nematode dauer juveniles is a sit-and-wait behaviour, otherwise known as nictation. Here, we test the function of nictation by relating occurrence of nictation in Pristionchus pacificus dauer juveniles to the ability to attach to laboratory host Galleria mellonella. We used populations of recently isolated and mutagenized laboratory strains. We found that nictation can be disrupted using a classical forward genetic approach and characterized two novel nictation-defective mutant strains. We identified two recently isolated strains from la Réunion island, one with a higher proportion of nictating individuals than the laboratory strain P. pacificus PS312. We found a positive correlation between nictation frequencies and host attachment in these strains. Taken together, our combination of genetic analyses with natural variation studies presents a new approach to the investigation of behavioural and ecological functionality. We show that nictation behaviour in P. pacificus nematodes serves as a host-finding behaviour. Our results suggest that nictation plays a role in the evolution of new life-history strategies, such as the evolution of parasitism.

  9. Quality knowledge of science through virtual laboratory as an element of visualization

    NASA Astrophysics Data System (ADS)

    Rizman Herga, Natasa

    Doctoral dissertation discusses the use of virtual laboratory for learning and teaching chemical concepts at science classes in the seventh grade of primary school. The dissertation has got a two-part structure. In the first theoretical part presents a general platform of teaching science in elementary school, teaching forms and methods of teaching and among modern approaches we highlight experimental work. Particular emphasis was placed on the use of new technologies in education and virtual laboratories. Scientific findings on the importance of visualization of science concepts and their triple nature of their understanding are presented. These findings represent a fundamental foundation of empirical research presented in the second part of the doctoral dissertation, whose basic purpose was to examine the effectiveness of using virtual laboratory for teaching and learning chemical contents at science from students' point of view on knowledge and interest. We designed a didactic experiment in which 225 pupils participated. The work was conducted in the experimental and control group. Prior to its execution, the existing school practice among science and chemistry teachers was analysed in terms of: (1) inclusion of experimental work as a fundamental method of active learning chemical contents, (2) the use of visualization methods in the classroom and (3) the use of a virtual laboratory. The main findings of the empirical research, carried out in the school year 2012/2013, in which 48 science and chemistry participated, are that teachers often include experimental work when teaching chemical contents. Interviewed science teachers use a variety of visualization methods when presenting science concepts, in particular computer animation and simulation. Using virtual laboratory as a new strategy for teaching and learning chemical contents is not common because teachers lack special-didactic skills, enabling them to use virtual reality technology. Based on the didactic

  10. Why REM sleep? Clues beyond the laboratory in a more challenging world.

    PubMed

    Horne, Jim

    2013-02-01

    REM sleep (REM) seems more likely to prepare for ensuing wakefulness rather than provides recovery from prior wakefulness, as happens with 'deeper' nonREM. Many of REM's characteristics are 'wake-like' (unlike nonREM), including several common to feeding. These, with recent findings outside sleep, provide perspectives on REM beyond those from the laboratory. REM can interchange with a wakefulness involving motor output, indicating that REM's atonia is integral to its function. Wakefulness for 'wild' mammals largely comprises exploration; a complex opportunistic behaviour mostly for foraging, involving: curiosity, minimising risks, (emotional) coping, navigation, when (including circadian timing) to investigate new destinations; all linked to 'purposeful, goal directed movement'. REM reflects these adaptive behaviours (including epigenesis), masked in laboratories having constrained, safe, unchanging, unchallenging, featureless, exploration-free environments with ad lib food. Similarly masked may be REM's functions for today's humans living safe, routine lives, with easy food accessibility. In these respects animal and human REM studies are not sufficiently 'ecological'. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. The Laboratory-Based Economics Curriculum.

    ERIC Educational Resources Information Center

    King, Paul G.; LaRoe, Ross M.

    1991-01-01

    Describes the liberal arts, computer laboratory-based economics program at Denison University (Ohio). Includes as goals helping students to (1) understand deductive arguments, (2) learn to apply theory in real-world situations, and (3) test and modify theory when necessary. Notes that the program combines computer laboratory experiments for…

  12. NRCL-70, Review of the Activities of the Laboratories 1970.

    ERIC Educational Resources Information Center

    National Research Council of Canada, Ottawa (Ontario).

    Included are descriptions of activities of each of the 12 laboratories in the National Research Council of Canada, including background information and a summary of the studies (research) and results. The 12 laboratories in the NRCL are the following: Atlantic Regional Laboratory, Biochemistry Laboratory, Division of Biology, Division of Building…

  13. Telepathology in Sweden. A national study including all histopathology and cytology laboratories.

    PubMed

    Busch, C

    1992-12-01

    Quality improvement and standardization of diagnosis in histopathology and cytology are important for the future of the discipline. Nominal scale diagnoses dominate the practice and their standardization depends on relevant and reproducibly identifiable criteria as well as on communication of these among pathologists. Telepathology, i.e. the transmission of adequately detailed colour images of microscopic fields over the telephone network is now a realistic possibility. All 30 laboratories for histopathology and cytology in Sweden will have access to Telepathology work stations for at least 8 weeks each during 1992-1993. Two centers will have permanent stations from September 1992. The images will be transmitted over the ISDN network, allowing a compressed image to appear instantaneously. This image is then gradually and imperceptibly decompressed during 15-60 seconds, the time depending on the complexity of the image. A program for consultation and quality testing is being set up, which will be evaluated during 1993. Based on a recognition of the conditions for diagnosis in pathology and cytology indicated above, the Swedish Society of Pathology has initiated a project called "Telepathology in Sweden". It is a joint effort with active participation by Swedish Telecom and the Swedish Planning and Rationalization Institute for the Health and Social Services, Stockholm as well as by Innovativ Vision AB, Linköping, a company providing hard- and software for image analysis, image banks and communication.

  14. 40 CFR 262.102 - What special definitions are included in this subpart?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Laboratory Waste means a laboratory waste, defined in the Environmental Management Plan as posing significant potential hazards to human health or the environment and which must include RCRA “P” wastes, and may include... (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS APPLICABLE TO GENERATORS OF HAZARDOUS WASTE University...

  15. Severe hyponatraemia in foals: clinical findings, primary diagnosis and outcome.

    PubMed

    Collins, N M; Axon, J E; Carrick, J B; Russell, C M; Palmer, J E

    2016-06-01

    To evaluate severe hyponatraemia in foals presenting as medical emergencies to an intensive care unit (ICU) in order to determine the prevalence, clinical findings, primary diagnosis and outcome. Retrospective case study of records from Thoroughbred foals aged less than 3 months presenting to an ICU as medical emergencies in 2002-12; foals with severe hyponatraemia (serum sodium <122 mmol/L) on admission laboratory data were identified. Data retrieved included signalment, clinical findings, laboratory results, primary diagnosis, treatment and outcome. Severe hyponatraemia was identified in 69/1718 Thoroughbred foals (4%) presenting to the ICU during the study period. Of the 69 foals, 11 (15.9%) presented with neurological signs attributable to hyponatraemic encephalopathy and 7 of these foals had seizures; other neurological signs included obtundation, ataxia and apparent blindness. The three most common primary diagnoses of the 69 foals with severe hyponatraemia were renal disease (18/69, 26.1%), enterocolitis (16/69, 23.2%) and uroperitoneum (15/69, 21.7%). Treatment was directed at the primary disease and correction of the hyponatraemia. A total of 50 of the 69 foals (72.5%) with severe hyponatraemia survived to hospital discharge and 38 of them (76%) survived at least 12 months following discharge. The prevalence of severe hyponatraemia in this study population was 4%. The majority of foals with severe hyponatraemia did not demonstrate direct clinical manifestations as a result of the low serum sodium concentration. The outcome of foals with severe hyponatraemia was mostly favourable. © 2016 Australian Veterinary Association.

  16. [Safety in the Microbiology laboratory].

    PubMed

    Rojo-Molinero, Estrella; Alados, Juan Carlos; de la Pedrosa, Elia Gómez G; Leiva, José; Pérez, José L

    2015-01-01

    The normal activity in the laboratory of microbiology poses different risks - mainly biological - that can affect the health of their workers, visitors and the community. Routine health examinations (surveillance and prevention), individual awareness of self-protection, hazard identification and risk assessment of laboratory procedures, the adoption of appropriate containment measures, and the use of conscientious microbiological techniques allow laboratory to be a safe place, as records of laboratory-acquired infections and accidents show. Training and information are the cornerstones for designing a comprehensive safety plan for the laboratory. In this article, the basic concepts and the theoretical background on laboratory safety are reviewed, including the main legal regulations. Moreover, practical guidelines are presented for each laboratory to design its own safety plan according its own particular characteristics. Copyright © 2014 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  17. Expansion of syndromic vaccine preventable disease surveillance to include bacterial meningitis and Japanese encephalitis: evaluation of adapting polio and measles laboratory networks in Bangladesh, China and India, 2007-2008.

    PubMed

    Cavallaro, Kathleen F; Sandhu, Hardeep S; Hyde, Terri B; Johnson, Barbara W; Fischer, Marc; Mayer, Leonard W; Clark, Thomas A; Pallansch, Mark A; Yin, Zundong; Zuo, Shuyan; Hadler, Stephen C; Diorditsa, Serguey; Hasan, A S M Mainul; Bose, Anindya S; Dietz, Vance

    2015-02-25

    Surveillance for acute flaccid paralysis with laboratory confirmation has been a key strategy in the global polio eradication initiative, and the laboratory platform established for polio testing has been expanded in many countries to include surveillance for cases of febrile rash illness to identify measles and rubella cases. Vaccine-preventable disease surveillance is essential to detect outbreaks, define disease burden, guide vaccination strategies and assess immunization impact. Vaccines now exist to prevent Japanese encephalitis (JE) and some etiologies of bacterial meningitis. We evaluated the feasibility of expanding polio-measles surveillance and laboratory networks to detect bacterial meningitis and JE, using surveillance for acute meningitis-encephalitis syndrome in Bangladesh and China and acute encephalitis syndrome in India. We developed nine syndromic surveillance performance indicators based on international surveillance guidelines and calculated scores using supervisory visit reports, annual reports, and case-based surveillance data. Scores, variable by country and targeted disease, were highest for the presence of national guidelines, sustainability, training, availability of JE laboratory resources, and effectiveness of using polio-measles networks for JE surveillance. Scores for effectiveness of building on polio-measles networks for bacterial meningitis surveillance and specimen referral were the lowest, because of differences in specimens and techniques. Polio-measles surveillance and laboratory networks provided useful infrastructure for establishing syndromic surveillance and building capacity for JE diagnosis, but were less applicable for bacterial meningitis. Laboratory-supported surveillance for vaccine-preventable bacterial diseases will require substantial technical and financial support to enhance local diagnostic capacity. Published by Elsevier Ltd.

  18. College of American Pathologists' laboratory standards for next-generation sequencing clinical tests.

    PubMed

    Aziz, Nazneen; Zhao, Qin; Bry, Lynn; Driscoll, Denise K; Funke, Birgit; Gibson, Jane S; Grody, Wayne W; Hegde, Madhuri R; Hoeltge, Gerald A; Leonard, Debra G B; Merker, Jason D; Nagarajan, Rakesh; Palicki, Linda A; Robetorye, Ryan S; Schrijver, Iris; Weck, Karen E; Voelkerding, Karl V

    2015-04-01

    The higher throughput and lower per-base cost of next-generation sequencing (NGS) as compared to Sanger sequencing has led to its rapid adoption in clinical testing. The number of laboratories offering NGS-based tests has also grown considerably in the past few years, despite the fact that specific Clinical Laboratory Improvement Amendments of 1988/College of American Pathologists (CAP) laboratory standards had not yet been developed to regulate this technology. To develop a checklist for clinical testing using NGS technology that sets standards for the analytic wet bench process and for bioinformatics or "dry bench" analyses. As NGS-based clinical tests are new to diagnostic testing and are of much greater complexity than traditional Sanger sequencing-based tests, there is an urgent need to develop new regulatory standards for laboratories offering these tests. To develop the necessary regulatory framework for NGS and to facilitate appropriate adoption of this technology for clinical testing, CAP formed a committee in 2011, the NGS Work Group, to deliberate upon the contents to be included in the checklist. Results . -A total of 18 laboratory accreditation checklist requirements for the analytic wet bench process and bioinformatics analysis processes have been included within CAP's molecular pathology checklist (MOL). This report describes the important issues considered by the CAP committee during the development of the new checklist requirements, which address documentation, validation, quality assurance, confirmatory testing, exception logs, monitoring of upgrades, variant interpretation and reporting, incidental findings, data storage, version traceability, and data transfer confidentiality.

  19. Improving performance in the ED through laboratory information exchange systems.

    PubMed

    Raymond, Louis; Paré, Guy; Maillet, Éric; Ortiz de Guinea, Ana; Trudel, Marie-Claude; Marsan, Josianne

    2018-03-12

    The accessibility of laboratory test results is crucial to the performance of emergency departments and to the safety of patients. This study aims to develop a better understanding of which laboratory information exchange (LIE) systems emergency care physicians (ECPs) are using to consult their patients' laboratory test results and which benefits they derive from such use. A survey of 163 (36%) ECPs in Quebec was conducted in collaboration with the Quebec's Department of Health and Social Services. Descriptive statistics, chi-square tests, cluster analyses, and ANOVAs were conducted. The great majority of respondents indicated that they use several LIE systems including interoperable electronic health record (iEHR) systems, laboratory results viewers (LRVs), and emergency department information systems (EDIS) to consult their patients' laboratory results. Three distinct profiles of LIE users were observed. The extent of LIE usage was found to be primarily determined by the functional design differences between LIE systems available in the EDs. Our findings also indicate that the more widespread LIE usage, the higher the perceived benefits. More specifically, physicians who make extensive use of iEHR systems and LRVs obtain the widest range of benefits in terms of efficiency, quality, and safety of emergency care. Extensive use of LIE systems allows ECPs to better determine and monitor the health status of their patients, verify their diagnostic assumptions, and apply evidence-based practices in laboratory medicine. But for such benefits to be possible, ECPs must be provided with LIE systems that produce accurate, up-to-date, complete, and easy-to-interpret information.

  20. Summary findings of the fourth international radiocarbon intercomparison (FIRI)(1998-2001)

    NASA Astrophysics Data System (ADS)

    Boaretto, Elisabetta; Bryant, Charlotte; Carmi, Israel; Cook, Gordon; Gulliksen, Steinar; Harkness, Doug; Heinemeier, Jan; McClure, John; McGee, Edward; Naysmith, Philip; Possnert, Goran; Scott, Marian; van der Plicht, Hans; van Strydonck, Mark

    2002-10-01

    Interlaboratory comparisons have been widely used in applied radiocarbon science. These are an important part of ongoing quality assurance (QA) programmes, which are vital to the appropriate interpretation of the evidence provided by the 14C record in Quaternary applications (including climate change and environmental reconstruction). International comparisons of laboratory performance are an essential component of the quality assurance process in radiocarbon dating. If the user community is to have confidence in radiocarbon results, it needs to be assured that laboratories world wide are producing measurements that are reliable and in accordance with good practice. The findings from the most recent (completed in 2001) and extensive (more than 90 participating laboratories) radiocarbon intercomparison (FIRI) are reported here. This study was designed (i) to assess comparability, or otherwise, of the results from different laboratories and (ii) to quantify the extent and possible causes of any interlaboratory variation. The results demonstrate that there are no significant differences amongst the main measurement techniques (gas proportional counting, liquid scintillation counting and accelerator mass spectrometry (AMS)) but there is evidence of small laboratory offsets relative to known age samples for some laboratories. There is also evidence in some cases of underestimation of measurement precision. Approximately 10% of all results were classified as extreme (outliers) and these results were generated by 14% of the laboratories. Overall, the evidence supports the fact that radiocarbon laboratories are generally accurate and precise but that, notwithstanding internal QA procedures, some problems still occur, which can best be detected by participation in independent intercomparisons such as FIRI, where the results allow individual laboratories to assess their performance and to take remedial measures where necessary. The results from FIRI are significant in that

  1. Core courses in public health laboratory science and practice: findings from 2006 and 2011 surveys.

    PubMed

    DeBoy, John M; Beck, Angela J; Boulton, Matthew L; Kim, Deborah H; Wichman, Michael D; Luedtke, Patrick F

    2013-01-01

    We identified academic training courses or topics most important to the careers of U.S. public health, environmental, and agricultural laboratory (PHEAL) scientist-managers and directors, and determined what portions of the national PHEAL workforce completed these courses. We conducted electronic national surveys in 2006 and 2011, and analyzed data using numerical ranking, Chi-square tests comparing rates, and Spearman's formula measuring rank correlation. In 2006, 40 of 50 PHEAL directors identified 56 course topics as either important, useful, or not needed for someone in their position. These course topics were then ranked to provide a list of 31 core courses. In 2011, 1,659 of approximately 5,555 PHEAL scientific and technical staff, using a subset of 25 core courses, evidenced higher core course completion rates associated with higher-level job classification, advanced academic degree, and age. The 2011 survey showed that 287 PHEAL scientist-managers and directors, on average, completed 37.7% (n=5/13) of leadership/managerial core courses and 51.7% (n=6/12) of scientific core courses. For 1,659 laboratorians in all scientific and technical classifications, core-subject completion rates were higher in local laboratories (42.8%, n=11/25) than in state (36.0%, n=9/25), federal (34.4%, n=9/25), and university (31.2%, n=8/25) laboratories. There is a definable range of scientific, leadership, and managerial core courses needed by PHEAL scientist-managers and directors to function effectively in their positions. Potential PHEAL scientist-managers and directors need greater and continuing access to these courses, and academic and practice entities supporting development of this workforce should adopt curricula and core competencies aligned with these course topics.

  2. Validation of a laboratory and hospital information system in a medical laboratory accredited according to ISO 15189

    PubMed Central

    Biljak, Vanja Radisic; Ozvald, Ivan; Radeljak, Andrea; Majdenic, Kresimir; Lasic, Branka; Siftar, Zoran; Lovrencic, Marijana Vucic; Flegar-Mestric, Zlata

    2012-01-01

    Introduction The aim of the study was to present a protocol for laboratory information system (LIS) and hospital information system (HIS) validation at the Institute of Clinical Chemistry and Laboratory Medicine of the Merkur University Hospital, Zagreb, Croatia. Materials and methods: Validity of data traceability was checked by entering all test requests for virtual patient into HIS/LIS and printing corresponding barcoded labels that provided laboratory analyzers with the information on requested tests. The original printouts of the test results from laboratory analyzer(s) were compared with the data obtained from LIS and entered into the provided template. Transfer of data from LIS to HIS was examined by requesting all tests in HIS and creating real data in a finding generated in LIS. Data obtained from LIS and HIS were entered into a corresponding template. The main outcome measure was the accuracy of transfer obtained from laboratory analyzers and results transferred from LIS and HIS expressed as percentage (%). Results: The accuracy of data transfer from laboratory analyzers to LIS was 99.5% and of that from LIS to HIS 100%. Conclusion: We presented our established validation protocol for laboratory information system and demonstrated that a system meets its intended purpose. PMID:22384522

  3. Molecular epidemiology and virulence characteristics of Staphylococcus aureus nasal colonization in medical laboratory staff: comparison between microbiological and non-microbiological laboratories.

    PubMed

    Xie, Xiaoying; Dai, Xinlu; Ni, Lijia; Chen, Baiji; Luo, Zhaofan; Yao, Yandan; Wu, Xiquan; Li, Hongyu; Huang, Songyin

    2018-03-12

    Medical laboratory staff are a high-risk population for colonization of Staphylococcus aureus (S. aureus) due to direct and dense contact with the pathogens; however, there is limited information about this colonization. This study sought to determine the prevalence and molecular characteristics of nasal colonization by S. aureus in medical laboratory staff in Guangzhou, southern China, and to compare the differences between microbiological laboratory (MLS) and non-microbiological laboratory (NMLS) staff. S. aureus colonization was assessed by nasal swab cultures from 434 subjects, including 130 MLSs and 304 NMLSs from 33 hospitals in Guangzhou. All S. aureus isolates underwent the antimicrobial susceptibility test, virulence gene detection and molecular typing. The overall prevalence of S. aureus carriage was 20.1% (87/434), which was higher in MLSs than in NMLSs (26.2% vs. 17.4%, P < 0.05), while the prevalence of Methicillin-resistant S. aureus (MRSA) was similar. Living with hospital staff was associated with S. aureus carriage. The majority of the isolates harboured various virulence genes, and those in MLSs appeared less resistant to antibiotics and more virulent than their counterparts. A total of 37 different spa types were detected; among these, t338, t437, t189 and t701 were the most frequently encountered types. T338 was the main spa type contributing to nasal colonization Methicillin-sensitive S. aureus (MSSA) (13.0%), and t437-SCCmec IV was predominant in MRSA isolates (40%). These findings provide insight into the risk factors, molecular epidemiology and virulence gene profiles of S. aureus nasal carriage among the medical laboratory staff in Guangzhou.

  4. NASA's Propulsion Research Laboratory

    NASA Technical Reports Server (NTRS)

    2004-01-01

    The grand opening of NASA's new, world-class laboratory for research into future space transportation technologies located at the Marshall Space Flight Center (MSFC) in Huntsville, Alabama, took place in July 2004. The state-of-the-art Propulsion Research Laboratory (PRL) serves as a leading national resource for advanced space propulsion research. Its purpose is to conduct research that will lead to the creation and development of innovative propulsion technologies for space exploration. The facility is the epicenter of the effort to move the U.S. space program beyond the confines of conventional chemical propulsion into an era of greatly improved access to space and rapid transit throughout the solar system. The laboratory is designed to accommodate researchers from across the United States, including scientists and engineers from NASA, the Department of Defense, the Department of Energy, universities, and industry. The facility, with 66,000 square feet of useable laboratory space, features a high degree of experimental capability. Its flexibility allows it to address a broad range of propulsion technologies and concepts, such as plasma, electromagnetic, thermodynamic, and propellant propulsion. An important area of emphasis is the development and utilization of advanced energy sources, including highly energetic chemical reactions, solar energy, and processes based on fission, fusion, and antimatter. The Propulsion Research Laboratory is vital for developing the advanced propulsion technologies needed to open up the space frontier, and sets the stage of research that could revolutionize space transportation for a broad range of applications.

  5. Maximising resource allocation in the teaching laboratory: understanding student evaluations of teaching assistants in a team-based teaching format

    NASA Astrophysics Data System (ADS)

    Nikolic, Sasha; Suesse, Thomas F.; McCarthy, Timothy J.; Goldfinch, Thomas L.

    2017-11-01

    Minimal research papers have investigated the use of student evaluations on the laboratory, a learning medium usually run by teaching assistants with little control of the content, delivery and equipment. Finding the right mix of teaching assistants for the laboratory can be an onerous task due to the many skills required including theoretical and practical know-how, troubleshooting, safety and class management. Using larger classes with multiple teaching assistants, a team-based teaching (TBT) format may be advantageous. A rigorous three-year study across twenty-five courses over repetitive laboratory classes is analysed using a multi-level statistical model considering students, laboratory classes and courses. The study is used to investigate the effectiveness of the TBT format, and quantify the influence each demonstrator has on the laboratory experience. The study found that TBT is effective and the lead demonstrator most influential, influencing up to 55% of the laboratory experience evaluation.

  6. Specialized Laboratory Information Systems.

    PubMed

    Dangott, Bryan

    2015-06-01

    Some laboratories or laboratory sections have unique needs that traditional anatomic and clinical pathology systems may not address. A specialized laboratory information system (LIS), which is designed to perform a limited number of functions, may perform well in areas where a traditional LIS falls short. Opportunities for specialized LISs continue to evolve with the introduction of new testing methodologies. These systems may take many forms, including stand-alone architecture, a module integrated with an existing LIS, a separate vendor-supplied module, and customized software. This article addresses the concepts underlying specialized LISs, their characteristics, and in what settings they are found. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Specialized Laboratory Information Systems.

    PubMed

    Dangott, Bryan

    2016-03-01

    Some laboratories or laboratory sections have unique needs that traditional anatomic and clinical pathology systems may not address. A specialized laboratory information system (LIS), which is designed to perform a limited number of functions, may perform well in areas where a traditional LIS falls short. Opportunities for specialized LISs continue to evolve with the introduction of new testing methodologies. These systems may take many forms, including stand-alone architecture, a module integrated with an existing LIS, a separate vendor-supplied module, and customized software. This article addresses the concepts underlying specialized LISs, their characteristics, and in what settings they are found. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Clinical, radiological and laboratory findings in 185 children with tuberculous meningitis at a single centre and relationship with the stage of the disease.

    PubMed

    Güneş, Ali; Uluca, Ünal; Aktar, Fesih; Konca, Çapan; Şen, Velat; Ece, Aydın; Hoşoğlu, Salih; Taş, Mehmet Ali; Gürkan, Fuat

    2015-10-15

    A delay in the diagnosis and treatment of tuberculosis meningitis (TBM) may lead to increased mortality and morbidity. The aim of this study was to describe the clinical, radiological and laboratory findings of TBM on a cohort of 185 pediatric patients at a single centre over a 10 year period and to investigate relationship between the stage of the disease. The hospital records of 185 TBM children that presented to the Pediatric Clinics of Dicle University Hospital were retrospectively evaluated. The age, gender, family history of tuberculosis, result of Mantoux skin test, status of BCG vaccination, stage of TBM at hospitalization, and clinical, laboratory and radiological features were recorded. Clinical staging of TBM was defined as follows: Stage I, no focal neurological findings and Glasgow Coma Scale (GCS) score 15; Stage II, GCS 15 presenting with focal neurological deficit or all the patients with GCS 10-14; Stage III, all the patients with GCS < 10. Relationships between results and stages of TBM were investigated. The mean age of the patients was 53.5 ± 44.9 months (4 months-18 years). 121 (65.4 %) of the patients were male and 64 (34.6 %) female. Family history of tuberculosis was defined in 62 (33.5 %) patients. Forty five (24.3 %) children had BCG vaccination scar. Mantoux skin test was interpreted as positive in 35 (18.9 %) patients. Sixty-eight (36.8 %) children were at stage I TBM, 57 (30.8 %) at stage II and 60 (32.4 %) were at stage III on admission. Mean duration of hospitalization was 23.9 ± 14.1 days. Totally, 90 patients (48.6 %) had abnormal chest X-ray findings (parenchymal infiltration in 46 (24.9 %), mediastinal lymphadenopathy in 36 (19.5 %), miliary opacities in 25 (13.5 %), pleural effusion in 2 (1.1 %), and atelectasis in 2 (1.1 %) patients). One hundred sixty seven (90.3 %) patients had hydrocephalus in cranial computerized tomography. There were 24 (13.0 %) patients with positive culture for

  9. Project management: importance for diagnostic laboratories.

    PubMed

    Croxatto, A; Greub, G

    2017-07-01

    The need for diagnostic laboratories to improve both quality and productivity alongside personnel shortages incite laboratory managers to constantly optimize laboratory workflows, organization, and technology. These continuous modifications of the laboratories should be conducted using efficient project and change management approaches to maximize the opportunities for successful completion of the project. This review aims at presenting a general overview of project management with an emphasis on selected critical aspects. Conventional project management tools and models, such as HERMES, described in the literature, associated personal experience, and educational courses on management have been used to illustrate this review. This review presents general guidelines of project management and highlights their importance for microbiology diagnostic laboratories. As an example, some critical aspects of project management will be illustrated with a project of automation, as experienced at the laboratories of bacteriology and hygiene of the University Hospital of Lausanne. It is important to define clearly beforehand the objective of a project, its perimeter, its costs, and its time frame including precise duration estimates of each step. Then, a project management plan including explanations and descriptions on how to manage, execute, and control the project is necessary to continuously monitor the progression of a project to achieve its defined goals. Moreover, a thorough risk analysis with contingency and mitigation measures should be performed at each phase of a project to minimize the impact of project failures. The increasing complexities of modern laboratories mean clinical microbiologists must use several management tools including project and change management to improve the outcome of major projects and activities. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  10. Safety in the Chemical Laboratory: An Undergraduate Chemical Laboratory Safety Course.

    ERIC Educational Resources Information Center

    Nicholls, L. Jewel

    1982-01-01

    Describes a two-quarter hour college chemistry course focusing on laboratory safety. Includes lists of topics/assignments, problem sets (toxicology, storage, and energy) and videotapes, films, and slide sets used in the course. (JN)

  11. Laboratory errors and patient safety.

    PubMed

    Miligy, Dawlat A

    2015-01-01

    Laboratory data are extensively used in medical practice; consequently, laboratory errors have a tremendous impact on patient safety. Therefore, programs designed to identify and reduce laboratory errors, as well as, setting specific strategies are required to minimize these errors and improve patient safety. The purpose of this paper is to identify part of the commonly encountered laboratory errors throughout our practice in laboratory work, their hazards on patient health care and some measures and recommendations to minimize or to eliminate these errors. Recording the encountered laboratory errors during May 2008 and their statistical evaluation (using simple percent distribution) have been done in the department of laboratory of one of the private hospitals in Egypt. Errors have been classified according to the laboratory phases and according to their implication on patient health. Data obtained out of 1,600 testing procedure revealed that the total number of encountered errors is 14 tests (0.87 percent of total testing procedures). Most of the encountered errors lay in the pre- and post-analytic phases of testing cycle (representing 35.7 and 50 percent, respectively, of total errors). While the number of test errors encountered in the analytic phase represented only 14.3 percent of total errors. About 85.7 percent of total errors were of non-significant implication on patients health being detected before test reports have been submitted to the patients. On the other hand, the number of test errors that have been already submitted to patients and reach the physician represented 14.3 percent of total errors. Only 7.1 percent of the errors could have an impact on patient diagnosis. The findings of this study were concomitant with those published from the USA and other countries. This proves that laboratory problems are universal and need general standardization and bench marking measures. Original being the first data published from Arabic countries that

  12. LABORATORY DESIGN CONSIDERATIONS FOR SAFETY.

    ERIC Educational Resources Information Center

    National Safety Council, Chicago, IL. Campus Safety Association.

    THIS SET OF CONSIDERATIONS HAS BEEN PREPARED TO PROVIDE PERSONS WORKING ON THE DESIGN OF NEW OR REMODELED LABORATORY FACILITIES WITH A SUITABLE REFERENCE GUIDE TO DESIGN SAFETY. THERE IS NO DISTINCTION BETWEEN TYPES OF LABORATORY AND THE EMPHASIS IS ON GIVING GUIDES AND ALTERNATIVES RATHER THAN DETAILED SPECIFICATIONS. AREAS COVERED INCLUDE--(1)…

  13. A Choice of Terminals: Spatial Patterning in Computer Laboratories

    ERIC Educational Resources Information Center

    Spennemann, Dirk; Cornforth, David; Atkinson, John

    2007-01-01

    Purpose: This paper seeks to examine the spatial patterns of student use of machines in each laboratory to whether there are underlying commonalities. Design/methodology/approach: The research was carried out by assessing the user behaviour in 16 computer laboratories at a regional university in Australia. Findings: The study found that computers…

  14. Psychophysiological measures of cognitive workload in laboratory and flight

    NASA Technical Reports Server (NTRS)

    Wilson, Glenn F.; Badeau, Albert

    1993-01-01

    Psychophysiological data have been recorded during different levels of cognitive workload in laboratory and flight settings. Cardiac, eye blink, and brain data have shown meaningful changes as a function of the levels of mental workload. Increased cognitive workload is generally associated with increased heart rates, decreased blink rates and eye closures, and decreased evoked potential amplitudes. However, comparisons of laboratory and flight data show that direct transference of laboratory findings to the flight environment is not possible in many cases. While the laboratory data are valuable, a data base from flight is required so that 'real world' data can be properly interpreted.

  15. Epidemiology, clinical characteristics, laboratory findings and severity of respiratory syncytial virus acute lower respiratory infection in Malaysian children, 2008-2013.

    PubMed

    Ng, Khuen F; Tan, Kah K; Sam, Zhi H; Ting, Grace Ss; Gan, Wan Y

    2017-04-01

    The aim of this study is to describe epidemiology, clinical features, laboratory data and severity of respiratory syncytial virus (RSV) acute lower respiratory infection (ALRI) in Malaysian children and to determine risk factors associated with prolonged hospital stay, paediatric intensive care unit (PICU) admission and mortality. Retrospective data on demographics, clinical presentation, outcomes and laboratory findings of 450 children admitted into Tuanku Jaafar Hospital in Seremban, Malaysia from 2008 to 2013 with documented diagnosis of RSV ALRI were collected and analysed. Most admissions were children below 2 years old (85.8%; 386/450). Commonest symptoms were fever (84.2%; 379/450), cough (97.8%; 440/450) and rhinorrhea (83.6%; 376/450). The median age among febrile patients (n = 379) was 9.0 months with interquartile range (IQR) of 4.0-19.0 months whereas the median age among those who were apyrexial (n = 71) was 2 months with IQR of 1-6 months (P-value <0.001). 15.3% (69/450) needed intensive care and 1.6% (7/450) died. Young age, history of prematurity, chronic comorbidity and thrombocytosis were significantly associated with prolonged hospital stay, PICU admission and mortality. Infants less than 6 months old with RSV ALRI tend to be afebrile at presentation. Younger age, history of prematurity, chronic comorbidity and thrombocytosis are predictors of severe RSV ALRI among Malaysian children. Case fatality rate for Malaysian children below 5 years of age with RSV ALRI in our centre is higher than what is seen in developed countries, suggesting that there is room for improvement. © 2016 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  16. Regulatory issues in accreditation of toxicology laboratories.

    PubMed

    Bissell, Michael G

    2012-09-01

    Clinical toxicology laboratories and forensic toxicology laboratories operate in a highly regulated environment. This article outlines major US legal/regulatory issues and requirements relevant to accreditation of toxicology laboratories (state and local regulations are not covered in any depth). The most fundamental regulatory distinction involves the purposes for which the laboratory operates: clinical versus nonclinical. The applicable regulations and the requirements and options for operations depend most basically on this consideration, with clinical toxicology laboratories being directly subject to federal law including mandated options for accreditation and forensic toxicology laboratories being subject to degrees of voluntary or state government–required accreditation.

  17. New Webpage Brings Increased Visibility to Frederick National Laboratory Subcontracting Opportunities | Frederick National Laboratory for Cancer Research

    Cancer.gov

    A new webpage will now make it easier for small businesses and others to find and apply for Frederick National Laboratory for Cancer Research business opportunities. The new solicitations page, which launched on the Frederick National Lab website Aug

  18. Theory and laboratory astrophysics

    NASA Technical Reports Server (NTRS)

    Schramm, David N.; Mckee, Christopher F.; Alcock, Charles; Allamandola, Lou; Chevalier, Roger A.; Cline, David B.; Dalgarno, Alexander; Elmegreen, Bruce G.; Fall, S. Michael; Ferland, Gary J.

    1991-01-01

    Science opportunities in the 1990's are discussed. Topics covered include the large scale structure of the universe, galaxies, stars, star formation and the interstellar medium, high energy astrophysics, and the solar system. Laboratory astrophysics in the 1990's is briefly surveyed, covering such topics as molecular, atomic, optical, nuclear and optical physics. Funding recommendations are given for the National Science Foundation, NASA, and the Department of Energy. Recommendations for laboratory astrophysics research are given.

  19. Core Courses in Public Health Laboratory Science and Practice: Findings from 2006 and 2011 Surveys

    PubMed Central

    Beck, Angela J.; Boulton, Matthew L.; Kim, Deborah H.; Wichman, Michael D.; Luedtke, Patrick F.

    2013-01-01

    Objectives We identified academic training courses or topics most important to the careers of U.S. public health, environmental, and agricultural laboratory (PHEAL) scientist-managers and directors, and determined what portions of the national PHEAL workforce completed these courses. Methods We conducted electronic national surveys in 2006 and 2011, and analyzed data using numerical ranking, Chi-square tests comparing rates, and Spearman's formula measuring rank correlation. Results In 2006, 40 of 50 PHEAL directors identified 56 course topics as either important, useful, or not needed for someone in their position. These course topics were then ranked to provide a list of 31 core courses. In 2011, 1,659 of approximately 5,555 PHEAL scientific and technical staff, using a subset of 25 core courses, evidenced higher core course completion rates associated with higher-level job classification, advanced academic degree, and age. The 2011 survey showed that 287 PHEAL scientist-managers and directors, on average, completed 37.7% (n=5/13) of leadership/managerial core courses and 51.7% (n=6/12) of scientific core courses. For 1,659 laboratorians in all scientific and technical classifications, core-subject completion rates were higher in local laboratories (42.8%, n=11/25) than in state (36.0%, n=9/25), federal (34.4%, n=9/25), and university (31.2%, n=8/25) laboratories. Conclusions There is a definable range of scientific, leadership, and managerial core courses needed by PHEAL scientist-managers and directors to function effectively in their positions. Potential PHEAL scientist-managers and directors need greater and continuing access to these courses, and academic and practice entities supporting development of this workforce should adopt curricula and core competencies aligned with these course topics. PMID:23997310

  20. The stem cell laboratory: design, equipment, and oversight.

    PubMed

    Wesselschmidt, Robin L; Schwartz, Philip H

    2011-01-01

    This chapter describes some of the major issues to be considered when setting up a laboratory for the culture of human pluripotent stem cells (hPSCs). The process of establishing a hPSC laboratory can be divided into two equally important parts. One is completely administrative and includes developing protocols, seeking approval, and establishing reporting processes and documentation. The other part of establishing a hPSC laboratory involves the physical plant and includes design, equipment and personnel. Proper planning of laboratory operations and proper design of the physical layout of the stem cell laboratory so that meets the scope of planned operations is a major undertaking, but the time spent upfront will pay long-term returns in operational efficiency and effectiveness. A well-planned, organized, and properly equipped laboratory supports research activities by increasing efficiency and reducing lost time and wasted resources.

  1. The Construction of the Siam Photon Laboratory and Its Ripple Effects

    NASA Astrophysics Data System (ADS)

    Ishii, Takehiko

    2004-03-01

    The Siam Photon Laboratory of the National Synchrotron Research Center(NSRC) is a synchrotron radiation research facility built for promoting the scientific and technological research activity of the country and enhancing the human resources development. The accelerator complex was originally owned by the SORTEC Laboratory in Tsukuba and transferred to NSRC gratis. The storage ring design was renewed and the construction of the whole accelerator complex with the reformed storage ring was completed two years ago. In the course of the construction, we found many problems distinctive of second hand machines. The maximum stored current and the beam lifetime at present are 210mA and 6hr at 100mA, respectively. One beam line for photoemission experiments has been opened to outside users. First experimental studies made on Ni(111) by our staff members has been completed. Since the project started from scratch, NSRC was asked to carry out all work necessary for opening the facility to outside users, The work includes collecting users and setting up the users organization. In industrial applications, for instance, we have to find either some government or private sectors who are interested in the fundamantal technological research using synchrotorn radiation. Then, the training of users from the relevant organizations will start. After the establishment of the Siam Photon Laboratory, the trend of the promotion of pertinent research has increased. More fundamental human resources development including the graduate school education is underway around the Siam Photon Laboratory. The growth of enterprises as a part of the infrastructure is slow but steady.

  2. Cocaine Use among the College Age Group: Biological and Psychological Effects--Clinical and Laboratory Research Findings.

    ERIC Educational Resources Information Center

    Nicholi, Armand M., Jr.

    1984-01-01

    Knowledge about cocaine's effect on the human mind and body is limited and not clearly documented. This article discusses various biological and psychological effects of the drug based on clinical and laboratory studies of man. (Author/DF)

  3. Expansion of syndromic vaccine preventable disease surveillance to include bacterial meningitis and Japanese encephalitis: Evaluation of adapting polio and measles laboratory networks in Bangladesh, China and India, 2007–2008

    PubMed Central

    Cavallaro, Kathleen F.; Sandhu, Hardeep S.; Hyde, Terri B.; Johnson, Barbara W.; Fischer, Marc; Mayer, Leonard W.; Clark, Thomas A.; Pallansch, Mark A.; Yin, Zundong; Zuo, Shuyan; Hadler, Stephen C.; Diorditsa, Serguey; Hasan, A.S.M. Mainul; Bose, Anindya S.; Dietz, Vance

    2016-01-01

    Background Surveillance for acute flaccid paralysis with laboratory confirmation has been a key strategy in the global polio eradication initiative, and the laboratory platform established for polio testing has been expanded in many countries to include surveillance for cases of febrile rash illness to identify measles and rubella cases. Vaccine-preventable disease surveillance is essential to detect outbreaks, define disease burden, guide vaccination strategies and assess immunization impact. Vaccines now exist to prevent Japanese encephalitis (JE) and some etiologies of bacterial meningitis. Methods We evaluated the feasibility of expanding polio–measles surveillance and laboratory networks to detect bacterial meningitis and JE, using surveillance for acute meningitis-encephalitis syndrome in Bangladesh and China and acute encephalitis syndrome in India. We developed nine syndromic surveillance performance indicators based on international surveillance guidelines and calculated scores using supervisory visit reports, annual reports, and case-based surveillance data. Results Scores, variable by country and targeted disease, were highest for the presence of national guidelines, sustainability, training, availability of JE laboratory resources, and effectiveness of using polio–measles networks for JE surveillance. Scores for effectiveness of building on polio–measles networks for bacterial meningitis surveillance and specimen referral were the lowest, because of differences in specimens and techniques. Conclusions Polio–measles surveillance and laboratory networks provided useful infrastructure for establishing syndromic surveillance and building capacity for JE diagnosis, but were less applicable for bacterial meningitis. Laboratory-supported surveillance for vaccine-preventable bacterial diseases will require substantial technical and financial support to enhance local diagnostic capacity. PMID:25597940

  4. Cysticercosis in laboratory rabbits.

    PubMed

    Owiny, J R

    2001-03-01

    There are no data on the current incidence of Taenia pisiformis in laboratory rabbits. Two cases of cysticercosis most likely due to T. pisiformis in laboratory rabbits (intermediate host) are presented. Both rabbits had no contact with dogs (final host); their caretakers did not work with dogs, and these caretakers changed into facility scrubs and wore gloves when working with the rabbits. Rabbit 1 may have been infected after being fed hay at our facility. In light of the life cycle of the parasite and the history of rabbit 2, it potentially could have been infected prior to arrival at our facility. There have been only three cases of tapeworm cysts in rabbits in our facility (average daily census, 250) during the last 10 years (incidence, < 1%). This report indicates that although cysticercosis is rare in laboratory rabbits, one should always be aware of such incidental findings. Although it may not produce overt illness in the rabbit, hepatic migration could adversely affect the outcome of some experimental procedures

  5. Statistical Analysis Tools for Learning in Engineering Laboratories.

    ERIC Educational Resources Information Center

    Maher, Carolyn A.

    1990-01-01

    Described are engineering programs that have used automated data acquisition systems to implement data collection and analyze experiments. Applications include a biochemical engineering laboratory, heat transfer performance, engineering materials testing, mechanical system reliability, statistical control laboratory, thermo-fluid laboratory, and a…

  6. Autoimmune hepatitis in 828 Brazilian children and adolescents: clinical and laboratory findings, histological profile, treatments, and outcomes.

    PubMed

    Porta, Gilda; Carvalho, Elisa de; Santos, Jorge L; Gama, Jorge; Borges, Cristian V; Seixas, Renata B P M; Ferreira, Alexandre R; Miura, Irene K; Silveira, Themis R; Silva, Luciana R; Fagundes, Eleonora D T; Bellomo-Brandao, Maria A; Sawamura, Regina; Vieira, Sandra M; Melere, Melina U; Marques, Cibele D F; Pugliese, Renata P; Danesi, Vera L; Porta, Adriana; Marsillac, Marise E; Valladares, Marcia A; Menezes, Daniela G; Kieling, Carlos; Paula, Mariana N de; Vasconcelos, Juliana R; Ferreira, Cristina T; Perin, Nilza; Resende, Leonardo R; Maia, Jussara; Tommaso, Adriana M A De; Hessel, Gabriel

    2018-05-30

    This large study with a long-term follow-up aimed to evaluate the clinical presentation, laboratory findings, histological profile, treatments, and outcomes of children and adolescents with autoimmune hepatitis. The medical records of 828 children and adolescents with autoimmune hepatitis were reviewed. A questionnaire was used to collect anonymous data on clinical presentation, biochemical and histological findings, and treatments. Of all patients, 89.6% had autoimmune hepatitis-1 and 10.4% had autoimmune hepatitis-2. The female sex was predominant in both groups. The median age at symptom onset was 111.5 (6; 210) and 53.5 (8; 165) months in the patients with autoimmune hepatitis 1 and autoimmune hepatitis-2, respectively. Acute clinical onset was observed in 56.1% and 58.8% and insidious symptoms in 43.9% and 41.2% of the patients with autoimmune hepatitis-1 and autoimmune hepatitis-2, respectively. The risk of hepatic failure was 1.6-fold higher for autoimmune hepatitis-2. Fulminant hepatic failure occurred in 3.6% and 10.6% of the patients with autoimmune hepatitis-1 and autoimmune hepatitis-2, respectively; the risk was 3.1-fold higher for autoimmune hepatitis-2. The gamma globulin and immunoglobulin G levels were significantly higher in autoimmune hepatitis-1, while the immunoglobulin A and C3 levels were lower in autoimmune hepatitis-2. Cirrhosis was observed in 22.4% of the patients; biochemical remission was achieved in 76.2%. The actuarial survival rate was 93.0%. A total of 4.6% underwent liver transplantation, and 6.9% died (autoimmune hepatitis-1: 7.5%; autoimmune hepatitis-2: 2.4%). In this large clinical series of Brazilian children and adolescents, autoimmune hepatitis-1 was more frequent, and patients with autoimmune hepatitis-2 exhibited higher disease remission rates with earlier response to treatment. Patients with autoimmune hepatitis-1 had a higher risk of death. Copyright © 2018. Published by Elsevier Editora Ltda.

  7. Chronic myelogenous leukemia: laboratory diagnosis and monitoring.

    PubMed

    Wang, Y L; Bagg, A; Pear, W; Nowell, P C; Hess, J L

    2001-10-01

    Rapid developments have occurred both in laboratory medicine and in therapeutic interventions for the management of patients with chronic myelogenous leukemia (CML). With a wide array of laboratory tests available, selecting the appropriate test for a specific diagnostic or therapeutic setting has become increasingly difficult. In this review, we first discuss, from the point of view of laboratory medicine, the advantages and disadvantages of several commonly used laboratory assays, including cytogenetics, fluorescence in situ hybridization (FISH), and qualitative and quantitative reverse transcriptase-polymerase chain reaction (RT-PCR). We then discuss, from the point of view of clinical care, the test(s) of choice for the most common clinical scenarios, including diagnosis and monitoring of the therapeutic response and minimal residual disease in patients treated with different therapies. The purpose of this review is to help clinicians and laboratory physicians select appropriate tests for the diagnosis and monitoring of CML, with the ultimate goal of improving the cost-effective usage of clinical laboratories and improving patient care. Copyright 2001 Wiley-Liss, Inc.

  8. Clinical laboratory waste management in Shiraz, Iran.

    PubMed

    Askarian, Mehrdad; Motazedian, Nasrin; Palenik, Charles John

    2012-06-01

    Clinical laboratories are significant generators of infectious waste, including microbiological materials, contaminated sharps, and pathologic wastes such as blood specimens and blood products. Most waste produced in laboratories can be disposed of in the general solid waste stream. However, improper management of infectious waste, including mixing general wastes with infectious wastes and improper handling or storage, could lead to disease transmission. The aim of this study was to assess waste management processes used at clinical laboratories in Shiraz, Iran. One hundred and nine clinical laboratories participated In this cross sectional study, Data collection was by questionnaire and direct observation. Of the total amount of waste generated, 52% (by weight) was noninfectious domestic waste, 43% was non-sharps infectious waste and 5% consisted of sharps. There was no significant relationship between laboratory staff or manager education and the score for quality of waste collection and disposal at clinical laboratories. Improvements in infectious waste management processes should involve clearer, more uniformly accepted definitions of infectious waste and increased staff training.

  9. Structural Test Laboratory | Water Power | NREL

    Science.gov Websites

    Structural Test Laboratory Structural Test Laboratory NREL engineers design and configure structural components can validate models, demonstrate system reliability, inform design margins, and assess , including mass and center of gravity, to ensure compliance with design goals Dynamic Characterization Use

  10. A Laboratory Safety Program at Delaware.

    ERIC Educational Resources Information Center

    Whitmyre, George; Sandler, Stanley I.

    1986-01-01

    Describes a laboratory safety program at the University of Delaware. Includes a history of the program's development, along with standard safety training and inspections now being implemented. Outlines a two-day laboratory safety course given to all graduate students and staff in chemical engineering. (TW)

  11. Laboratory issues: use of nutritional biomarkers.

    PubMed

    Blanck, Heidi Michels; Bowman, Barbara A; Cooper, Gerald R; Myers, Gary L; Miller, Dayton T

    2003-03-01

    Biomarkers of nutritional status provide alternative measures of dietary intake. Like the error and variation associated with dietary intake measures, the magnitude and impact of both biological (preanalytical) and laboratory (analytical) variability need to be considered when one is using biomarkers. When choosing a biomarker, it is important to understand how it relates to nutritional intake and the specific time frame of exposure it reflects as well as how it is affected by sampling and laboratory procedures. Biological sources of variation that arise from genetic and disease states of an individual affect biomarkers, but they are also affected by nonbiological sources of variation arising from specimen collection and storage, seasonality, time of day, contamination, stability and laboratory quality assurance. When choosing a laboratory for biomarker assessment, researchers should try to make sure random and systematic error is minimized by inclusion of certain techniques such as blinding of laboratory staff to disease status and including external pooled standards to which laboratory staff are blinded. In addition analytic quality control should be ensured by use of internal standards or certified materials over the entire range of possible values to control method accuracy. One must consider the effect of random laboratory error on measurement precision and also understand the method's limit of detection and the laboratory cutpoints. Choosing appropriate cutpoints and reducing error is extremely important in nutritional epidemiology where weak associations are frequent. As part of this review, serum lipids are included as an example of a biomarker whereby collaborative efforts have been put forth to both understand biological sources of variation and standardize laboratory results.

  12. Herbal medicine for the management of polycystic ovary syndrome (PCOS) and associated oligo/amenorrhoea and hyperandrogenism; a review of the laboratory evidence for effects with corroborative clinical findings.

    PubMed

    Arentz, Susan; Abbott, Jason Anthony; Smith, Caroline Anne; Bensoussan, Alan

    2014-12-18

    Polycystic ovary syndrome (PCOS) is a prevalent, complex endocrine disorder characterised by polycystic ovaries, chronic anovulation and hyperandrogenism leading to symptoms of irregular menstrual cycles, hirsutism, acne and infertility. Evidence based medical management emphasises a multidisciplinary approach for PCOS, as conventional pharmaceutical treatment addresses single symptoms, may be contra-indicated, is often associated with side effects and not effective in some cases. In addition women with PCOS have expressed a strong desire for alternative treatments. This review examines the reproductive endocrine effects in PCOS for an alternative treatment, herbal medicine. The aim of this review was to identify consistent evidence from both pre-clinical and clinical research, to add to the evidence base for herbal medicine in PCOS (and associated oligo/amenorrhoea and hyperandrogenism) and to inform herbal selection in the provision clinical care for these common conditions. We undertook two searches of the scientific literature. The first search sought pre-clinical studies which explained the reproductive endocrine effects of whole herbal extracts in oligo/amenorrhoea, hyperandrogenism and PCOS. Herbal medicines from the first search informed key words for the second search. The second search sought clinical studies, which corroborated laboratory findings. Subjects included women with PCOS, menstrual irregularities and hyperandrogenism. A total of 33 studies were included in this review. Eighteen pre-clinical studies reported mechanisms of effect and fifteen clinical studies corroborated pre-clinical findings, including eight randomised controlled trials, and 762 women with menstrual irregularities, hyperandrogenism and/or PCOS. Interventions included herbal extracts of Vitex agnus-castus, Cimicifuga racemosa, Tribulus terrestris, Glycyrrhiza spp., Paeonia lactiflora and Cinnamomum cassia. Endocrine outcomes included reduced luteinising hormone (LH), prolactin

  13. Laboratory automation: trajectory, technology, and tactics.

    PubMed

    Markin, R S; Whalen, S A

    2000-05-01

    Laboratory automation is in its infancy, following a path parallel to the development of laboratory information systems in the late 1970s and early 1980s. Changes on the horizon in healthcare and clinical laboratory service that affect the delivery of laboratory results include the increasing age of the population in North America, the implementation of the Balanced Budget Act (1997), and the creation of disease management companies. Major technology drivers include outcomes optimization and phenotypically targeted drugs. Constant cost pressures in the clinical laboratory have forced diagnostic manufacturers into less than optimal profitability states. Laboratory automation can be a tool for the improvement of laboratory services and may decrease costs. The key to improvement of laboratory services is implementation of the correct automation technology. The design of this technology should be driven by required functionality. Automation design issues should be centered on the understanding of the laboratory and its relationship to healthcare delivery and the business and operational processes in the clinical laboratory. Automation design philosophy has evolved from a hardware-based approach to a software-based approach. Process control software to support repeat testing, reflex testing, and transportation management, and overall computer-integrated manufacturing approaches to laboratory automation implementation are rapidly expanding areas. It is clear that hardware and software are functionally interdependent and that the interface between the laboratory automation system and the laboratory information system is a key component. The cost-effectiveness of automation solutions suggested by vendors, however, has been difficult to evaluate because the number of automation installations are few and the precision with which operational data have been collected to determine payback is suboptimal. The trend in automation has moved from total laboratory automation to a

  14. Reliability on intra-laboratory and inter-laboratory data of hair mineral analysis comparing with blood analysis.

    PubMed

    Namkoong, Sun; Hong, Seung Phil; Kim, Myung Hwa; Park, Byung Cheol

    2013-02-01

    Nowadays, although its clinical value remains controversial institutions utilize hair mineral analysis. Arguments about the reliability of hair mineral analysis persist, and there have been evaluations of commercial laboratories performing hair mineral analysis. The objective of this study was to assess the reliability of intra-laboratory and inter-laboratory data at three commercial laboratories conducting hair mineral analysis, compared to serum mineral analysis. Two divided hair samples taken from near the scalp were submitted for analysis at the same time, to all laboratories, from one healthy volunteer. Each laboratory sent a report consisting of quantitative results and their interpretation of health implications. Differences among intra-laboratory and interlaboratory data were analyzed using SPSS version 12.0 (SPSS Inc., USA). All the laboratories used identical methods for quantitative analysis, and they generated consistent numerical results according to Friedman analysis of variance. However, the normal reference ranges of each laboratory varied. As such, each laboratory interpreted the patient's health differently. On intra-laboratory data, Wilcoxon analysis suggested they generated relatively coherent data, but laboratory B could not in one element, so its reliability was doubtful. In comparison with the blood test, laboratory C generated identical results, but not laboratory A and B. Hair mineral analysis has its limitations, considering the reliability of inter and intra laboratory analysis comparing with blood analysis. As such, clinicians should be cautious when applying hair mineral analysis as an ancillary tool. Each laboratory included in this study requires continuous refinement from now on for inducing standardized normal reference levels.

  15. 20 CFR 416.928 - Symptoms, signs, and laboratory findings.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... or mental impairment. If you are a child under age 18 and are unable to adequately describe your... abnormalities, e.g., abnormalities of behavior, mood, thought, memory, orientation, development, or perception... include chemical tests, electrophysiological studies (electrocardiogram, electroencephalogram, etc...

  16. 20 CFR 416.928 - Symptoms, signs, and laboratory findings.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... or mental impairment. If you are a child under age 18 and are unable to adequately describe your... abnormalities, e.g., abnormalities of behavior, mood, thought, memory, orientation, development, or perception... include chemical tests, electrophysiological studies (electrocardiogram, electroencephalogram, etc...

  17. 20 CFR 416.928 - Symptoms, signs, and laboratory findings.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... or mental impairment. If you are a child under age 18 and are unable to adequately describe your... abnormalities, e.g., abnormalities of behavior, mood, thought, memory, orientation, development, or perception... include chemical tests, electrophysiological studies (electrocardiogram, electroencephalogram, etc...

  18. 20 CFR 416.928 - Symptoms, signs, and laboratory findings.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... or mental impairment. If you are a child under age 18 and are unable to adequately describe your... abnormalities, e.g., abnormalities of behavior, mood, thought, memory, orientation, development, or perception... include chemical tests, electrophysiological studies (electrocardiogram, electroencephalogram, etc...

  19. 20 CFR 416.928 - Symptoms, signs, and laboratory findings.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... or mental impairment. If you are a child under age 18 and are unable to adequately describe your... abnormalities, e.g., abnormalities of behavior, mood, thought, memory, orientation, development, or perception... include chemical tests, electrophysiological studies (electrocardiogram, electroencephalogram, etc...

  20. Laboratory security and emergency response guidance for laboratories working with select agents. Centers for Disease Control and Prevention.

    PubMed

    Richmond, Jonathan Y; Nesby-O'Dell, Shanna L

    2002-12-06

    In recent years, concern has increased regarding use of biologic materials as agents of terrorism, but these same agents are often necessary tools in clinical and research microbiology laboratories. Traditional biosafety guidelines for laboratories have emphasized use of optimal work practices, appropriate containment equipment, well-designed facilities, and administrative controls to minimize risk of worker injury and to ensure safeguards against laboratory contamination. The guidelines discussed in this report were first published in 1999 (U.S. Department of Health and Human Services/CDC and National Institutes of Health. Biosafety in microbiological and biomedical laboratories [BMBL]. Richmond JY, McKinney RW, eds. 4th ed. Washington, DC: US Department of Health and Human Services, 1999 [Appendix F]). In that report, physical security concerns were addressed, and efforts were focused on preventing unauthorized entry to laboratory areas and preventing unauthorized removal of dangerous biologic agents from the laboratory. Appendix F of BMBL is now being revised to include additional information regarding personnel risk assessments, and inventory controls. The guidelines contained in this report are intended for laboratories working with select agents under biosafety-level 2, 3, or 4 conditions as described in Sections II and III of BMBL. These recommendations include conducting facility risk assessments and developing comprehensive security plans to minimize the probability of misuse of select agents. Risk assessments should include systematic, site-specific reviews of 1) physical security; 2) security of data and electronic technology systems; 3) employee security; 4) access controls to laboratory and animal areas; 5) procedures for agent inventory and accountability; 6) shipping/transfer and receiving of select agents; 7) unintentional incident and injury policies; 8) emergency response plans; and 9) policies that address breaches in security. The security plan

  1. Measuring laboratory-based influenza surveillance capacity: development of the 'International Influenza Laboratory Capacity Review' Tool.

    PubMed

    Muir-Paulik, S A; Johnson, L E A; Kennedy, P; Aden, T; Villanueva, J; Reisdorf, E; Humes, R; Moen, A C

    2016-01-01

    The 2005 International Health Regulations (IHR 2005) emphasized the importance of laboratory capacity to detect emerging diseases including novel influenza viruses. To support IHR 2005 requirements and the need to enhance influenza laboratory surveillance capacity, the Association of Public Health Laboratories (APHL) and the Centers for Disease Control and Prevention (CDC) Influenza Division developed the International Influenza Laboratory Capacity Review (Tool). Data from 37 assessments were reviewed and analyzed to verify that the quantitative analysis results accurately depicted a laboratory's capacity and capabilities. Subject matter experts in influenza and laboratory practice used an iterative approach to develop the Tool incorporating feedback and lessons learnt through piloting and implementation. To systematically analyze assessment data, a quantitative framework for analysis was added to the Tool. The review indicated that changes in scores consistently reflected enhanced or decreased capacity. The review process also validated the utility of adding a quantitative analysis component to the assessments and the benefit of establishing a baseline from which to compare future assessments in a standardized way. Use of the Tool has provided APHL, CDC and each assessed laboratory with a standardized analysis of the laboratory's capacity. The information generated is used to improve laboratory systems for laboratory testing and enhance influenza surveillance globally. We describe the development of the Tool and lessons learnt. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. The Stem Cell Laboratory: Design, Equipment, and Oversight

    PubMed Central

    Wesselschmidt, Robin L.; Schwartz, Philip H.

    2013-01-01

    This chapter describes some of the major issues to be considered when setting up a laboratory for the culture of human pluripotent stem cells (hPSCs). The process of establishing a hPSC laboratory can be divided into two equally important parts. One is completely administrative and includes developing protocols, seeking approval, and establishing reporting processes and documentation. The other part of establishing a hPSC laboratory involves the physical plant and includes design, equipment and personnel. Proper planning of laboratory operations and proper design of the physical layout of the stem cell laboratory so that meets the scope of planned operations is a major undertaking, but the time spent upfront will pay long-term returns in operational efficiency and effectiveness. A well-planned, organized, and properly equipped laboratory supports research activities by increasing efficiency and reducing lost time and wasted resources. PMID:21822863

  3. 77 FR 46438 - Findings of Research Misconduct

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-03

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Office of the Secretary Findings of Research Misconduct... Research Integrity (ORI) has taken final action in the following case: Mepur H. Ravindranath, Ph.D., John... H. Ravindranath, former Director of the Laboratory of Glycoimmunotheraphy, JWCI, engaged in research...

  4. A Self-Paced Physical Geology Laboratory.

    ERIC Educational Resources Information Center

    Watson, Donald W.

    1983-01-01

    Describes a self-paced geology course utilizing a diversity of instructional techniques, including maps, models, samples, audio-visual materials, and a locally developed laboratory manual. Mechanical features are laboratory exercises, followed by unit quizzes; quizzes are repeated until the desired level of competence is attained. (Author/JN)

  5. Nonanalytic Laboratory Automation: A Quarter Century of Progress.

    PubMed

    Hawker, Charles D

    2017-06-01

    Clinical laboratory automation has blossomed since the 1989 AACC meeting, at which Dr. Masahide Sasaki first showed a western audience what his laboratory had implemented. Many diagnostics and other vendors are now offering a variety of automated options for laboratories of all sizes. Replacing manual processing and handling procedures with automation was embraced by the laboratory community because of the obvious benefits of labor savings and improvement in turnaround time and quality. Automation was also embraced by the diagnostics vendors who saw automation as a means of incorporating the analyzers purchased by their customers into larger systems in which the benefits of automation were integrated to the analyzers.This report reviews the options that are available to laboratory customers. These options include so called task-targeted automation-modules that range from single function devices that automate single tasks (e.g., decapping or aliquoting) to multifunction workstations that incorporate several of the functions of a laboratory sample processing department. The options also include total laboratory automation systems that use conveyors to link sample processing functions to analyzers and often include postanalytical features such as refrigerated storage and sample retrieval.Most importantly, this report reviews a recommended process for evaluating the need for new automation and for identifying the specific requirements of a laboratory and developing solutions that can meet those requirements. The report also discusses some of the practical considerations facing a laboratory in a new implementation and reviews the concept of machine vision to replace human inspections. © 2017 American Association for Clinical Chemistry.

  6. Laboratory development and testing of spacecraft diagnostics

    NASA Astrophysics Data System (ADS)

    Amatucci, William; Tejero, Erik; Blackwell, Dave; Walker, Dave; Gatling, George; Enloe, Lon; Gillman, Eric

    2017-10-01

    The Naval Research Laboratory's Space Chamber experiment is a large-scale laboratory device dedicated to the creation of large-volume plasmas with parameters scaled to realistic space plasmas. Such devices make valuable contributions to the investigation of space plasma phenomena under controlled, reproducible conditions, allowing for the validation of theoretical models being applied to space data. However, in addition to investigations such as plasma wave and instability studies, such devices can also make valuable contributions to the development and testing of space plasma diagnostics. One example is the plasma impedance probe developed at NRL. Originally developed as a laboratory diagnostic, the sensor has now been flown on a sounding rocket, is included on a CubeSat experiment, and will be included on the DoD Space Test Program's STP-H6 experiment on the International Space Station. In this talk, we will describe how the laboratory simulation of space plasmas made this development path possible. Work sponsored by the US Naval Research Laboratory Base Program.

  7. Laboratory exercises on oscillation modes of pipes

    NASA Astrophysics Data System (ADS)

    Haeberli, Willy

    2009-03-01

    This paper describes an improved lab setup to study the vibrations of air columns in pipes. Features of the setup include transparent pipes which reveal the position of a movable microphone inside the pipe; excitation of pipe modes with a miniature microphone placed to allow access to the microphone stem for open, closed, or conical pipes; and sound insulation to avoid interference between different setups in a student lab. The suggested experiments on the modes of open, closed, and conical pipes, the transient response of a pipe, and the effect of pipe diameter are suitable for introductory physics laboratories, including laboratories for nonscience majors and music students, and for more advanced undergraduate laboratories. For honors students or for advanced laboratory exercises, the quantitative relation between the resonance width and damping time constant is of interest.

  8. Baseline Morbidity in 2,990 Adult African Volunteers Recruited to Characterize Laboratory Reference Intervals for Future HIV Vaccine Clinical Trials

    PubMed Central

    Stevens, Wendy; Kamali, Anatoli; Karita, Etienne; Anzala, Omu; Sanders, Eduard J.; Jaoko, Walter; Kaleebu, Pontiano; Mulenga, Joseph; Dally, Len; Fast, Pat; Gilmour, Jill; Farah, Bashir; Birungi, Josephine; Hughes, Peter; Manigart, Olivier; Stevens, Gwynn; Yates, Sarah; Thomson, Helen; von Lieven, Andrea; Krebs, Marietta; Price, Matt A.; Stoll-Johnson, Lisa; Ketter, Nzeera

    2008-01-01

    Background An understanding of the health of potential volunteers in Africa is essential for the safe and efficient conduct of clinical trials, particularly for trials of preventive technologies such as vaccines that enroll healthy individuals. Clinical safety laboratory values used for screening, enrolment and follow-up of African clinical trial volunteers have largely been based on values derived from industrialized countries in Europe and North America. This report describes baseline morbidity during recruitment for a multi-center, African laboratory reference intervals study. Methods Asymptomatic persons, aged 18–60 years, were invited to participate in a cross-sectional study at seven sites (Kigali, Rwanda; Masaka and Entebbe, Uganda; Kangemi, Kenyatta National Hospital and Kilifi, Kenya; and Lusaka, Zambia). Gender equivalency was by design. Individuals who were acutely ill, pregnant, menstruating, or had significant clinical findings were not enrolled. Each volunteer provided blood for hematology, immunology, and biochemistry parameters and urine for urinalysis. Enrolled volunteers were excluded if found to be positive for HIV, syphilis or Hepatitis B and C. Laboratory assays were conducted under Good Clinical Laboratory Practices (GCLP). Results and Conclusions Of the 2990 volunteers who were screened, 2387 (80%) were enrolled, and 2107 (71%) were included in the analysis (52% men, 48% women). Major reasons for screening out volunteers included abnormal findings on physical examination (228/603, 38%), significant medical history (76, 13%) and inability to complete the informed consent process (73, 13%). Once enrolled, principle reasons for exclusion from analysis included detection of Hepatitis B surface antigen (106/280, 38%) and antibodies against Hepatitis C (95, 34%). This is the first large scale, multi-site study conducted to the standards of GCLP to describe African laboratory reference intervals applicable to potential volunteers in clinical

  9. Clinical and laboratory features of canine Anaplasma platys infection in 32 naturally infected dogs in the Mediterranean basin.

    PubMed

    Bouzouraa, Tarek; René-Martellet, Magalie; Chêne, Jeanne; Attipa, Charalampos; Lebert, Isabelle; Chalvet-Monfray, Karine; Cadoré, Jean-Luc; Halos, Lenaig; Chabanne, Luc

    2016-10-01

    Since the first description of Anaplasma platys Infection (ApI), the disease has been sporadically reported worldwide. Whereas it is considered a subclinical disease in the United States or in Australia, severe cases are reported in Europe. Thus far, little information is available regarding the clinical and laboratory findings associated with the disease and the implication of co-infections with other vector-borne pathogens (VBPs) in Southern Europe. The purpose of the study was to describe clinical and laboratory findings in PCR-confirmed naturally infected dogs in the Mediterranean Basin, and to assess the potential impact of co-infections with other VBPs. This is a retrospective analysis of medical records from 32 client-owned dogs diagnosed with ApI using PCR-based assays. Anorexia (62.5%) and weight loss (43.8%) were the major changes, whereas lethargy was less frequent (34.4%). Lymphadenomegaly (43.8%), hyperthermia (40.6%) and hemorrhage (37.5%) were frequent clinical abnormalities, whereas cutaneous signs (31.3%), musculoskeletal disorders (21.9%), splenomegaly (15.6%), dehydration and ocular inflammation (12.5%) were less common. Hematological abnormalities included thrombocytopenia (81.0%), anemia (81.0%), leukocytosis (33.3%) and leucopenia (23.8%). Seven dogs (33.3%) were severely thrombocytopenic. Among the 28 dogs with complete testing, 15 and 13 were mono- and co-infected, respectively. Co-infections included Ehrlichia canis (3 dogs), Leishmania infantum (4), Babesia vogeli (2) and Hepatozoon canis (5). One dog was infected concurrently with Anaplasma platys, Ehrlichia canis and Babesia vogeli. The 1-month mortality rate was 23.9% and only 38.1% improved. In the univariate analysis the 15 mono- and the 13 co-infected dogs did not differ regarding the relative frequencies of clinical and laboratory findings. Sequencing and phylogenetic analyses suggested the existence of 2 different groups of strains: one of them might have higher pathogenicity. In

  10. Environmental Audit of the Environmental Measurements Laboratory (EML)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-02-01

    This document contains the findings identified during the Environmental Audit of the Environmental Measurements Laboratory (EML), conducted from December 2 to 13, 1991. The Audit included the EML facility located in a fifth-floor General Services Administration (GSA) office building located in New York City, and a remote environmental monitoring station located in Chester, New Jersey. The scope of this Environmental Audit was comprehensive, covering all areas of environmental activities and waste management operations, with the exception of the National Environmental Policy Act (NEPA), which is the responsibility of the DOE Headquarters Office of NEPA Oversight. Compliance with applicable Federal, state,more » and local requirements; applicable DOE Orders; and internal facility requirements was addressed.« less

  11. External quality assessment of medical laboratories in Croatia: preliminary evaluation of post-analytical laboratory testing.

    PubMed

    Krleza, Jasna Lenicek; Dorotic, Adrijana; Grzunov, Ana

    2017-02-15

    Proper standardization of laboratory testing requires assessment of performance after the tests are performed, known as the post-analytical phase. A nationwide external quality assessment (EQA) scheme implemented in Croatia in 2014 includes a questionnaire on post-analytical practices, and the present study examined laboratory responses in order to identify current post-analytical phase practices and identify areas for improvement. In four EQA exercises between September 2014 and December 2015, 145-174 medical laboratories across Croatia were surveyed using the Module 11 questionnaire on the post-analytical phase of testing. Based on their responses, the laboratories were evaluated on four quality indicators: turnaround time (TAT), critical values, interpretative comments and procedures in the event of abnormal results. Results were presented as absolute numbers and percentages. Just over half of laboratories (56.3%) monitored TAT. Laboratories varied substantially in how they dealt with critical values. Most laboratories (65-97%) issued interpretative comments with test results. One third of medical laboratories (30.6-33.3%) issued abnormal test results without confirming them in additional testing. Our results suggest that the nationwide post-analytical EQA scheme launched in 2014 in Croatia has yet to be implemented to the full. To close the gaps between existing recommendations and laboratory practice, laboratory professionals should focus on ensuring that TAT is monitored and lists of critical values are established within laboratories. Professional bodies/institutions should focus on clarify and harmonized rules to standardized practices and applied for adding interpretative comments to laboratory test results and for dealing with abnormal test results.

  12. A qualitative case study of instructional support for web-based simulated laboratory exercises in online college chemistry laboratory courses

    NASA Astrophysics Data System (ADS)

    Schulman, Kathleen M.

    This study fills a gap in the research literature regarding the types of instructional support provided by instructors in online introductory chemistry laboratory courses that employ chemistry simulations as laboratory exercises. It also provides information regarding students' perceptions of the effectiveness of that instructional support. A multiple case study methodology was used to carry out the research. Two online introductory chemistry courses were studied at two community colleges. Data for this study was collected using phone interviews with faculty and student participants, surveys completed by students, and direct observation of the instructional designs of instructional support in the online Blackboard web sites and the chemistry simulations used by the participating institutions. The results indicated that the instructors provided multiple types of instructional support that correlated with forms of effective instructional support identified in the research literature, such as timely detailed feedback, detailed instructions for the laboratory experiments, and consistency in the instructional design of lecture and laboratory course materials, including the chemistry lab simulation environment. The students in one of these courses identified the following as the most effective types of instructional support provided: the instructor's feedback, opportunities to apply chemistry knowledge in the chemistry lab exercises, detailed procedures for the simulated laboratory exercises, the organization of the course Blackboard sites and the chemistry lab simulation web sites, and the textbook homework web sites. Students also identified components of instructional support they felt were missing. These included a desire for more interaction with the instructor, more support for the simulated laboratory exercises from the instructor and the developer of the chemistry simulations, and faster help with questions about the laboratory exercises or experimental

  13. Differences in Ultrasonic Vocalizations between Wild and Laboratory California Mice (Peromyscus californicus)

    PubMed Central

    Kalcounis-Rueppell, Matina C.; Petric, Radmila; Briggs, Jessica R.; Carney, Catherine; Marshall, Matthew M.; Willse, John T.; Rueppell, Olav; Ribble, David O.; Crossland, Janet P.

    2010-01-01

    Background Ultrasonic vocalizations (USVs) emitted by muroid rodents, including laboratory mice and rats, are used as phenotypic markers in behavioral assays and biomedical research. Interpretation of these USVs depends on understanding the significance of USV production by rodents in the wild. However, there has never been a study of muroid rodent ultrasound function in the wild and comparisons of USVs produced by wild and laboratory rodents are lacking to date. Here, we report the first comparison of wild and captive rodent USVs recorded from the same species, Peromyscus californicus. Methodology and Principal Findings We used standard ultrasound recording techniques to measure USVs from California mice in the laboratory (Peromyscus Genetic Stock Center, SC, USA) and the wild (Hastings Natural History Reserve, CA, USA). To determine which California mouse in the wild was vocalizing, we used a remote sensing method that used a 12-microphone acoustic localization array coupled with automated radio telemetry of all resident Peromyscus californicus in the area of the acoustic localization array. California mice in the laboratory and the wild produced the same types of USV motifs. However, wild California mice produced USVs that were 2–8 kHz higher in median frequency and significantly more variable in frequency than laboratory California mice. Significance The similarity in overall form of USVs from wild and laboratory California mice demonstrates that production of USVs by captive Peromyscus is not an artifact of captivity. Our study validates the widespread use of USVs in laboratory rodents as behavioral indicators but highlights that particular characteristics of laboratory USVs may not reflect natural conditions. PMID:20368980

  14. Microwave remote sensing laboratory design

    NASA Technical Reports Server (NTRS)

    Friedman, E.

    1979-01-01

    Application of active and passive microwave remote sensing to the study of ocean pollution is discussed. Previous research efforts, both in the field and in the laboratory were surveyed to derive guidance for the design of a laboratory program of research. The essential issues include: choice of radar or radiometry as the observational technique; choice of laboratory or field as the research site; choice of operating frequency; tank sizes and material; techniques for wave generation and appropriate wavelength spectrum; methods for controlling and disposing of pollutants used in the research; and pollutants other than oil which could or should be studied.

  15. Laboratory and Field Investigations of Small Crater Repair Technologies

    DTIC Science & Technology

    2007-09-01

    caps over debris backfill or specially placed or compacted backfill, structural systems to bridge craters, foamed crater backfills, and structural ...Jeb S. Tingle, and Timothy J. McCaffrey Geotechnical and Structures Laboratory U.S. Army Engineer Research and Development Center 3909 Halls Ferry...Engineer Research and Development Center (ERDC), Geotechnical and Structures Laboratory (GSL), Vicksburg, MS. The findings and recommendations presented

  16. CAP/ACMG proficiency testing for biochemical genetics laboratories: a summary of performance.

    PubMed

    Oglesbee, Devin; Cowan, Tina M; Pasquali, Marzia; Wood, Timothy C; Weck, Karen E; Long, Thomas; Palomaki, Glenn E

    2018-01-01

    PurposeTesting for inborn errors of metabolism is performed by clinical laboratories worldwide, each utilizing laboratory-developed procedures. We sought to summarize performance in the College of American Pathologists' (CAP) proficiency testing (PT) program and identify opportunities for improving laboratory quality. When evaluating PT data, we focused on a subset of laboratories that have participated in at least one survey since 2010.MethodsAn analysis of laboratory performance (2004 to 2014) on the Biochemical Genetics PT Surveys, a program administered by CAP and the American College of Medical Genetics and Genomics. Analytical and interpretive performance was evaluated for four tests: amino acids, organic acids, acylcarnitines, and mucopolysaccharides.ResultsSince 2010, 150 laboratories have participated in at least one of four PT surveys. Analytic sensitivities ranged from 88.2 to 93.4%, while clinical sensitivities ranged from 82.4 to 91.0%. Performance was higher for US participants and for more recent challenges. Performance was lower for challenges with subtle findings or complex analytical patterns.ConclusionUS clinical biochemical genetics laboratory proficiency is satisfactory, with a minority of laboratories accounting for the majority of errors. Our findings underscore the complex nature of clinical biochemical genetics testing and highlight the necessity of continuous quality management.

  17. Categorization of fetal external findings in developmental toxicology studies by the Terminology Committee of the Japanese Teratology Society.

    PubMed

    Izumi, Yuko; Ooshima, Yojiro; Chihara, Kazuhiro; Fujiwara, Michio; Katsumata, Yoshihiro; Shiota, Kohei

    2018-05-01

    Categorization of fetal external findings in common laboratory animals, intended to make the agreement at Berlin Workshop in 2014 more practical, was proposed by the Terminology Committee of the Japanese Teratology Society at the Workshop in the 55th Japanese Teratology Society Annual Meeting in 2015. In the Workshop, 73 external findings, which had been categorized as "Gray zone" anomalies but not as "Malformation" or "Variation" in the 2014 Berlin Workshop, were discussed and classified as Malformation, "Non-structural abnormality," Variation, and "Not applicable." The proposal was based on the results of a survey conducted in 2014, where 20 facilities (including pharmaceutical, chemical, and pesticide companies and contract laboratories) and 2 selected expert teratologists in Japan were asked for their opinions on the categorization of these findings. Based on the discussion, Japanese Teratology Society members have agreed that 42 out of the 73 findings can be classified as Malformations (38), Non-structural abnormalities (3), Malformations/Non-structural abnormalities (1), and Variations (0), while the remaining 31 findings were recommended to be categorized as Not applicable for fetuses. The details of the classification are shown on the website of the Japanese Teratology Society (http://www.umin.ac.jp/cadb/External.pdf). © 2018 Japanese Teratology Society.

  18. Laboratories | NREL

    Science.gov Websites

    | Z A Accelerated Exposure Testing Laboratory Advanced Optical Materials Laboratory Advanced Thermal Laboratory Structural Testing Laboratory Surface Analysis Laboratory Systems Performance Laboratory T Thermal Storage Materials Laboratory Thermal Storage Process and Components Laboratory Thin-Film Deposition

  19. Recruitment and retention strategies for hospital laboratory personnel in urban and rural settings.

    PubMed

    Slagle, Derek R

    2013-01-01

    Laboratory directors and administrators play vital roles in the recruitment and retention processes of their employees. A total of 71 laboratory directors from hospitals across 51 counties in Tennessee responded to questionnaires regarding recruitment and retention strategies. Respondents reported strategies for recruitment and retention, which were agreed to be effective by management. Overall, these major strategies were consistent regardless of geographic location and limited differences were noted with regard to urban-rural locations. The findings that varied significantly between urban and rural locations included: 1) rural employees needed additional supervision; 2) rural hospitals relied on local residents more so than urban hospitals; 3) rural laboratory administrators noted more limited access to resources; and the 4) lower effectiveness of recruitment agencies and family relocation programs for rural hospitals. This is significant given the disparities often associated with rural areas, and the potential to develop more successful recruitment and retention strategies for those areas. Active managers in clinical laboratory science programs in the hospital setting should note effective strategies for both, recruitment and retention of personnel, and note the potential impact of geography on such processes.

  20. Promoting clinical and laboratory interaction by harmonization.

    PubMed

    Plebani, Mario; Panteghini, Mauro

    2014-05-15

    The lack of interchangeable results in current practice among clinical laboratories has underpinned greater attention to standardization and harmonization projects. Although the focus was mainly on the standardization and harmonization of measurement procedures and their results, the scope of harmonization goes beyond method and analytical results: it includes all other aspects of laboratory testing, including terminology and units, report formats, reference limits and decision thresholds, as well as test profiles and criteria for the interpretation of results. In particular, as evidence collected in last decades demonstrates that pre-pre- and post-post-analytical steps are more vulnerable to errors, harmonization initiatives should be performed to improve procedures and processes at the laboratory-clinical interface. Managing upstream demand, down-stream interpretation of laboratory results, and subsequent appropriate action through close relationships between laboratorians and clinicians remains a crucial issue of the laboratory testing process. Therefore, initiatives to improve test demand management from one hand and to harmonize procedures to improve physicians' acknowledgment of laboratory data and their interpretation from the other hand are needed in order to assure quality and safety in the total testing process. © 2013.

  1. Conservation Plan, Seaman Outdoor Laboratory for Environmental Education.

    ERIC Educational Resources Information Center

    Topeka Unified School District 345, KS.

    This guide focuses on the conservation plan for an outdoor laboratory. Although the plan focuses specifically on Seaman Outdoor Education Laboratory, the concepts could be applied to any natural area including parks, farms, and school grounds. Along with an introduction and justification, the guide includes the conservation plan that serves as the…

  2. Laboratory Safety Guide for Arkansas K-12 Schools.

    ERIC Educational Resources Information Center

    Arkansas State Dept. of Education, Little Rock.

    This document presents laboratory safety rules for Arkansas K-12 schools which were developed by the Arkansas Science Teachers Association (ASTA) and the Arkansas Department of Education (ADE). Contents include: (1) "Laboratory Safety Guide for Arkansas K-12 Schools"; (2) "Safety Considerations"; (3) "Safety Standards for Science Laboratories";…

  3. Safety in the Chemical Laboratory: Learning How to Run Safer Undergraduate Laboratories.

    ERIC Educational Resources Information Center

    Mohrig, Jerry R.

    1983-01-01

    Discusses responsibilities for providing safe experiments and for teaching about safety. Provides lists of references on chemical safety and regulated/potential carcinogens. Also discusses general laboratory safety procedures including waste disposal and recycling of solvents. (JM)

  4. Utilization of Educationally Oriented Microcomputer Based Laboratories

    ERIC Educational Resources Information Center

    Fitzpatrick, Michael J.; Howard, James A.

    1977-01-01

    Describes one approach to supplying engineering and computer science educators with an economical portable digital systems laboratory centered around microprocessors. Expansion of the microcomputer based laboratory concept to include Learning Resource Aided Instruction (LRAI) systems is explored. (Author)

  5. What do physicians tell laboratories when requesting tests? A multi-method examination of information supplied to the microbiology laboratory before and after the introduction of electronic ordering.

    PubMed

    Georgiou, Andrew; Prgomet, Mirela; Toouli, George; Callen, Joanne; Westbrook, Johanna

    2011-09-01

    The provision of relevant clinical information on pathology requests is an important part of facilitating appropriate laboratory utilization and accurate results interpretation and reporting. (1) To determine the quantity and importance of handwritten clinical information provided by physicians to the Microbiology Department of a hospital pathology service; and (2) to examine the impact of a Computerized Provider Order Entry (CPOE) system on the nature of clinical information communication to the laboratory. A multi-method and multi-stage investigation which included: (a) a retrospective audit of all handwritten Microbiology requests received over a 1-month period in the Microbiology Department of a large metropolitan teaching hospital; (b) the administration of a survey to laboratory professionals to investigate the impact of different clinical information on the processing and/or interpretation of tests; (c) an expert panel consisting of medical staff and senior scientists to assess the survey findings and their impact on pathology practice and patient care; and (d) a comparison of the provision and value of clinical information before CPOE, and across 3 years after its implementation. The audit of handwritten requests found that 43% (n=4215) contained patient-related clinical information. The laboratory survey showed that 97% (84/86) of the different types of clinical information provided for wound specimens and 86% (43/50) for stool specimens were shown to have an effect on the processing or interpretation of the specimens by one or more laboratory professionals. The evaluation of the impact of CPOE revealed a significant improvement in the provision of useful clinical information from 2005 to 2008, rising from 90.1% (n=749) to 99.8% (n=915) (p<.0001) for wound specimens and 34% (n=129) to 86% (n=422) (p<.0001) for stool specimens. This study showed that the CPOE system provided an integrated platform to access and exchange valuable patient-related information

  6. An Online Virtual Laboratory of Electricity

    ERIC Educational Resources Information Center

    Gómez Tejedor, J. A.; Moltó Martínez, G.; Barros Vidaurre, C.

    2008-01-01

    In this article, we describe a Java-based virtual laboratory, accessible via the Internet by means of a Web browser. This remote laboratory enables the students to build both direct and alternating current circuits. The program includes a graphical user interface which resembles the connection board, and also the electrical components and tools…

  7. Laboratory Diagnosis of Congenital Toxoplasmosis.

    PubMed

    Pomares, Christelle; Montoya, Jose G

    2016-10-01

    Recent studies have demonstrated that screening and treatment for toxoplasmosis during gestation result in a decrease of vertical transmission and clinical sequelae. Early treatment was associated with improved outcomes. Thus, laboratory methods should aim for early identification of infants with congenital toxoplasmosis (CT). Diagnostic approaches should include, at least, detection of Toxoplasma IgG, IgM, and IgA and a comprehensive review of maternal history, including the gestational age at which the mother was infected and treatment. Here, we review laboratory methods for the diagnosis of CT, with emphasis on serological tools. A diagnostic algorithm that takes into account maternal history is presented. Copyright © 2016 Pomares and Montoya.

  8. Laboratory Diagnosis of Congenital Toxoplasmosis

    PubMed Central

    Pomares, Christelle

    2016-01-01

    Recent studies have demonstrated that screening and treatment for toxoplasmosis during gestation result in a decrease of vertical transmission and clinical sequelae. Early treatment was associated with improved outcomes. Thus, laboratory methods should aim for early identification of infants with congenital toxoplasmosis (CT). Diagnostic approaches should include, at least, detection of Toxoplasma IgG, IgM, and IgA and a comprehensive review of maternal history, including the gestational age at which the mother was infected and treatment. Here, we review laboratory methods for the diagnosis of CT, with emphasis on serological tools. A diagnostic algorithm that takes into account maternal history is presented. PMID:27147724

  9. Competitive bidding for Medicare Part B clinical laboratory services.

    PubMed

    Kautter, John; Pope, Gregory C

    2014-06-01

    The traditional Medicare fee-for-service program may be able to purchase clinical laboratory test services at a lower cost through competitive bidding. Demonstrations of competitive bidding for clinical laboratory tests have been twice mandated or authorized by Congress but never implemented. This article provides a summary and review of the final design of the laboratory competitive bidding demonstration mandated by the Medicare Modernization Act of 2003. The design was analogous to a sealed bid (first price), clearing price auction. Design elements presented include covered laboratory tests and beneficiaries, laboratory bidding and payment status under the demonstration, composite bids, determining bidding winners and the demonstration fee schedule, and quality under the demonstration. Expanded use of competitive bidding in Medicare, including specifically for clinical laboratory tests, has been recommended in some proposals for Medicare reform. The presented design may be a useful point of departure if Medicare clinical laboratory competitive bidding is revived in the future.

  10. Safety in the Chemical Laboratory: Fire Safety and Fire Control in the Chemistry Laboratory.

    ERIC Educational Resources Information Center

    Wilbraham, A. C.

    1979-01-01

    Discusses fire safety and fire control in the chemistry laboratory. The combustion process, extinguishing equipment, extinguisher maintenance and location, and fire safety and practices are included. (HM)

  11. Autonomy and Privacy in Clinical Laboratory Science Policy and Practice.

    PubMed

    Leibach, Elizabeth Kenimer

    2014-01-01

    Rapid advancements in diagnostic technologies coupled with growth in testing options and choices mandate the development of evidence-based testing algorithms linked to the care paths of the major chronic diseases and health challenges encountered most frequently. As care paths are evaluated, patient/consumers become partners in healthcare delivery. Clinical laboratory scientists find themselves firmly embedded in both quality improvement and clinical research with an urgent need to translate clinical laboratory information into knowledge required by practitioners and patient/consumers alike. To implement this patient-centered care approach in clinical laboratory science, practitioners must understand their roles in (1) protecting patient/consumer autonomy in the healthcare informed consent process and (2) assuring patient/consumer privacy and confidentiality while blending quality improvement study findings with protected health information. A literature review, describing the current ethical environment, supports a consultative role for clinical laboratory scientists in the clinical decision-making process and suggests guidance for policy and practice regarding the principle of autonomy and its associated operational characteristics: informed consent and privacy.

  12. Oak Ridge National Laboratory Institutional Plan, FY 1995--FY 2000

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-11-01

    This report discusses the institutional plan for Oak Ridge National Laboratory for the next five years (1995-2000). Included in this report are the: laboratory director`s statement; laboratory mission, vision, and core competencies; laboratory plan; major laboratory initiatives; scientific and technical programs; critical success factors; summaries of other plans; and resource projections.

  13. Making Connections in the Undergraduate Laboratory.

    ERIC Educational Resources Information Center

    Poole, Bobbie J.; Kidder, Stanley Q.

    1996-01-01

    Describes a strategy used in a meteorology course to increase its relevance to students' lives. Involves combining the lecture and laboratory portions of the course and including a Connections section in the lab report in which students comment on the connections they saw between the coursework, the laboratory exercises, and their own experience.…

  14. Laboratory directed research and development program, FY 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1997-02-01

    The Ernest Orlando Lawrence Berkeley National Laboratory (Berkeley Lab) Laboratory Directed Research and Development Program FY 1996 report is compiled from annual reports submitted by principal investigators following the close of the fiscal year. This report describes the projects supported and summarizes their accomplishments. It constitutes a part of the Laboratory Directed Research and Development (LDRD) program planning and documentation process that includes an annual planning cycle, projection selection, implementation, and review. The Berkeley Lab LDRD program is a critical tool for directing the Laboratory`s forefront scientific research capabilities toward vital, excellent, and emerging scientific challenges. The program provides themore » resources for Berkeley Lab scientists to make rapid and significant contributions to critical national science and technology problems. The LDRD program also advances the Laboratory`s core competencies, foundations, and scientific capability, and permits exploration of exciting new opportunities. Areas eligible for support include: (1) Work in forefront areas of science and technology that enrich Laboratory research and development capability; (2) Advanced study of new hypotheses, new experiments, and innovative approaches to develop new concepts or knowledge; (3) Experiments directed toward proof of principle for initial hypothesis testing or verification; and (4) Conception and preliminary technical analysis to explore possible instrumentation, experimental facilities, or new devices.« less

  15. Materials Science Laboratory

    NASA Technical Reports Server (NTRS)

    Jackson, Dionne

    2005-01-01

    The NASA Materials Science Laboratory (MSL) provides science and engineering services to NASA and Contractor customers at KSC, including those working for the Space Shuttle. International Space Station. and Launch Services Programs. These services include: (1) Independent/unbiased failure analysis (2) Support to Accident/Mishap Investigation Boards (3) Materials testing and evaluation (4) Materials and Processes (M&P) engineering consultation (5) Metrology (6) Chemical analysis (including ID of unknown materials) (7) Mechanical design and fabrication We provide unique solutions to unusual and urgent problems associated with aerospace flight hardware, ground support equipment and related facilities.

  16. Culturing and Using Protozoans in the Laboratory.

    ERIC Educational Resources Information Center

    Hummer, Paul J., Jr.

    1993-01-01

    Provides instructions for teachers and students to culture protozoans for use in science laboratories. Sections include setting up a culture area, basic culture media, amoeba culture technique, powdered milk-wheat-rice medium, alfalfa medium, and uses of the protozoa in the laboratory. (PR)

  17. The Viability of Distance Education Science Laboratories.

    ERIC Educational Resources Information Center

    Forinash, Kyle; Wisman, Raymond

    2001-01-01

    Discusses the effectiveness of offering science laboratories via distance education. Explains current delivery technologies, including computer simulations, videos, and laboratory kits sent to students; pros and cons of distance labs; the use of spreadsheets; and possibilities for new science education models. (LRW)

  18. Meta-analysis of the effectiveness of computer-based laboratory versus traditional hands-on laboratory in college and pre-college science instructions

    NASA Astrophysics Data System (ADS)

    Onuoha, Cajetan O.

    The purpose of this research study was to determine the overall effectiveness of computer-based laboratory compared with the traditional hands-on laboratory for improving students' science academic achievement and attitudes towards science subjects at the college and pre-college levels of education in the United States. Meta-analysis was used to synthesis the findings from 38 primary research studies conducted and/or reported in the United States between 1996 and 2006 that compared the effectiveness of computer-based laboratory with the traditional hands-on laboratory on measures related to science academic achievements and attitudes towards science subjects. The 38 primary research studies, with total subjects of 3,824 generated a total of 67 weighted individual effect sizes that were used in this meta-analysis. The study found that computer-based laboratory had small positive effect sizes over the traditional hands-on laboratory (ES = +0.26) on measures related to students' science academic achievements and attitudes towards science subjects (ES = +0.22). It was also found that computer-based laboratory produced more significant effects on physical science subjects compared to biological sciences (ES = +0.34, +0.17).

  19. Adding Audio Supported Smartboard Lectures to an Introductory Astronomy Online Laboratory

    NASA Astrophysics Data System (ADS)

    Lahaise, U. G. L.

    2003-12-01

    SMART Board(TM) and RealProducer(R) Plus technologies were used to develop a series of narrated pre-lab introductory online lectures. Smartboard slides were created by capturing images from internet pages and power point slides, then annotated and saved as web pages using smartboard technology. Short audio files were recorded using the RealProducer Plus software which were then linked to individual slides. WebCT was used to deliver the online laboratory. Students in an Introductory Astronomy of the Solar System Online laboratory used the lectures to prepare for laboratory exercises. The narrated pre-lab lectures were added to six out of eight suitable laboratory exercises. A survey was given to the students to research their online laboratory experience, in general, and the impact of the narrated smartboard lectures on their learning success, specifically. Data were collected for two accelerated sessions. Results show that students find the online laboratory equally hard or harder than a separate online lecture. The accelerated format created great time pressure which negatively affected their study habits. About half of the students used the narrated pre-lab lectures consistently. Preliminary findings show that lab scores in the accelerated sessions were brought up to the level of full semester courses.

  20. USGS Scientific Visualization Laboratory

    USGS Publications Warehouse

    ,

    1995-01-01

    The U.S. Geological Survey's (USGS) Scientific Visualization Laboratory at the National Center in Reston, Va., provides a central facility where USGS employees can use state-of-the-art equipment for projects ranging from presentation graphics preparation to complex visual representations of scientific data. Equipment including color printers, black-and-white and color scanners, film recorders, video equipment, and DOS, Apple Macintosh, and UNIX platforms with software are available for both technical and nontechnical users. The laboratory staff provides assistance and demonstrations in the use of the hardware and software products.

  1. Recovery of Silver and Cobalt from Laboratory Wastes.

    ERIC Educational Resources Information Center

    Foust, Donald F.

    1984-01-01

    Procedures for recovering silver and cobalt from laboratory wastes (including those resulting from student experiments) are presented. The procedures are generally applicable since only common, inexpensive laboratory reagents are needed. (JN)

  2. Insights from a Modular Interdisciplinary Laboratory Course

    NASA Astrophysics Data System (ADS)

    Bouvier-Brown, N. C.; Carmona, V.

    2016-12-01

    A laboratory curriculum is naturally oriented towards "hands on" and problem-based learning. An earth science course, like chemical ecology, has the additional advantage of interdisciplinary education. Our Chemical Ecology course at Loyola Marymount University was structured as a small modular workshop. Students first gained hands-on experience with each analytical technique in the laboratory. The class then discussed these first datasets, delved into lecture topics, and tweaked their experimental procedures. Lastly, students were given time to design and execute their own experiments and present their findings. Three-to-four class periods were allotted for each laboratory topic. Detailed information and student reflections will be presented from the Spectroscopy module. Students used the Folin-Ciocalteau reagent method to extract the phenolic content of vegetation and/or soils. Because phenols are produced by plants for defense, this spectroscopic laboratory activity provided insight on allelopathy using analytical chemistry. Students were extremely engaged and learned not only the lab theory and technique, but also its application to our local ecology.

  3. Research and Development. Laboratory Activities.

    ERIC Educational Resources Information Center

    Gallaway, Ann, Ed.

    Research and Development is a laboratory-oriented course that includes the appropriate common essential elements for industrial technology education plus concepts and skills related to research and development. This guide provides teachers of the course with learning activities for secondary students. Introductory materials include an…

  4. Powder X-ray diffraction laboratory, Reston, Virginia

    USGS Publications Warehouse

    Piatak, Nadine M.; Dulong, Frank T.; Jackson, John C.; Folger, Helen W.

    2014-01-01

    The powder x-ray diffraction (XRD) laboratory is managed jointly by the Eastern Mineral and Environmental Resources and Eastern Energy Resources Science Centers. Laboratory scientists collaborate on a wide variety of research problems involving other U.S. Geological Survey (USGS) science centers and government agencies, universities, and industry. Capabilities include identification and quantification of crystalline and amorphous phases, and crystallographic and atomic structure analysis for a wide variety of sample media. Customized laboratory procedures and analyses commonly are used to characterize non-routine samples including, but not limited to, organic and inorganic components in petroleum source rocks, ore and mine waste, clay minerals, and glassy phases. Procedures can be adapted to meet a variety of research objectives.

  5. Inter-laboratory validation of bioaccessibility testing for metals.

    PubMed

    Henderson, Rayetta G; Verougstraete, Violaine; Anderson, Kim; Arbildua, José J; Brock, Thomas O; Brouwers, Tony; Cappellini, Danielle; Delbeke, Katrien; Herting, Gunilla; Hixon, Greg; Odnevall Wallinder, Inger; Rodriguez, Patricio H; Van Assche, Frank; Wilrich, Peter; Oller, Adriana R

    2014-10-01

    Bioelution assays are fast, simple alternatives to in vivo testing. In this study, the intra- and inter-laboratory variability in bioaccessibility data generated by bioelution tests were evaluated in synthetic fluids relevant to oral, inhalation, and dermal exposure. Using one defined protocol, five laboratories measured metal release from cobalt oxide, cobalt powder, copper concentrate, Inconel alloy, leaded brass alloy, and nickel sulfate hexahydrate. Standard deviations of repeatability (sr) and reproducibility (sR) were used to evaluate the intra- and inter-laboratory variability, respectively. Examination of the sR:sr ratios demonstrated that, while gastric and lysosomal fluids had reasonably good reproducibility, other fluids did not show as good concordance between laboratories. Relative standard deviation (RSD) analysis showed more favorable reproducibility outcomes for some data sets; overall results varied more between- than within-laboratories. RSD analysis of sr showed good within-laboratory variability for all conditions except some metals in interstitial fluid. In general, these findings indicate that absolute bioaccessibility results in some biological fluids may vary between different laboratories. However, for most applications, measures of relative bioaccessibility are needed, diminishing the requirement for high inter-laboratory reproducibility in absolute metal releases. The inter-laboratory exercise suggests that the degrees of freedom within the protocol need to be addressed. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Laboratory simulation of space plasma phenomena*

    NASA Astrophysics Data System (ADS)

    Amatucci, B.; Tejero, E. M.; Ganguli, G.; Blackwell, D.; Enloe, C. L.; Gillman, E.; Walker, D.; Gatling, G.

    2017-12-01

    Laboratory devices, such as the Naval Research Laboratory's Space Physics Simulation Chamber, are large-scale experiments dedicated to the creation of large-volume plasmas with parameters realistically scaled to those found in various regions of the near-Earth space plasma environment. Such devices make valuable contributions to the understanding of space plasmas by investigating phenomena under carefully controlled, reproducible conditions, allowing for the validation of theoretical models being applied to space data. By working in collaboration with in situ experimentalists to create realistic conditions scaled to those found during the observations of interest, the microphysics responsible for the observed events can be investigated in detail not possible in space. To date, numerous investigations of phenomena such as plasma waves, wave-particle interactions, and particle energization have been successfully performed in the laboratory. In addition to investigations such as plasma wave and instability studies, the laboratory devices can also make valuable contributions to the development and testing of space plasma diagnostics. One example is the plasma impedance probe developed at NRL. Originally developed as a laboratory diagnostic, the sensor has now been flown on a sounding rocket, is included on a CubeSat experiment, and will be included on the DoD Space Test Program's STP-H6 experiment on the International Space Station. In this presentation, we will describe several examples of the laboratory investigation of space plasma waves and instabilities and diagnostic development. *This work supported by the NRL Base Program.

  7. NACA Computer at the Lewis Flight Propulsion Laboratory

    NASA Image and Video Library

    1951-02-21

    A female computer at the National Advisory Committee for Aeronautics (NACA) Lewis Flight Propulsion Laboratory with a slide rule and Friden adding machine to make computations. The computer staff was introduced during World War II to relieve short-handed research engineers of some of the tedious computational work. The Computing Section was staffed by “computers,” young female employees, who often worked overnight when most of the tests were run. The computers obtained test data from the manometers and other instruments, made the initial computations, and plotted the data graphically. Researchers then analyzed the data and summarized the findings in a report or made modifications and ran the test again. There were over 400 female employees at the laboratory in 1944, including 100 computers. The use of computers was originally planned only for the duration of the war. The system was so successful that it was extended into the 1960s. The computers and analysts were located in the Altitude Wind Tunnel Shop and Office Building office wing during the 1940s and transferred to the new 8- by 6-Foot Supersonic Wind Tunnel in 1948.

  8. Early variations of laboratory parameters predicting shunt-dependent hydrocephalus after subarachnoid hemorrhage.

    PubMed

    Na, Min Kyun; Won, Yu Deok; Kim, Choong Hyun; Kim, Jae Min; Cheong, Jin Hwan; Ryu, Je Il; Han, Myung-Hoon

    2017-01-01

    Hydrocephalus is a frequent complication following subarachnoid hemorrhage. Few studies investigated the association between laboratory parameters and shunt-dependent hydrocephalus. This study aimed to investigate the variations of laboratory parameters after subarachnoid hemorrhage. We also attempted to identify predictive laboratory parameters for shunt-dependent hydrocephalus. Multiple imputation was performed to fill the missing laboratory data using Bayesian methods in SPSS. We used univariate and multivariate Cox regression analyses to calculate hazard ratios for shunt-dependent hydrocephalus based on clinical and laboratory factors. The area under the receiver operating characteristic curve was used to determine the laboratory risk values predicting shunt-dependent hydrocephalus. We included 181 participants with a mean age of 54.4 years. Higher sodium (hazard ratio, 1.53; 95% confidence interval, 1.13-2.07; p = 0.005), lower potassium, and higher glucose levels were associated with higher shunt-dependent hydrocephalus. The receiver operating characteristic curve analysis showed that the areas under the curve of sodium, potassium, and glucose were 0.649 (cutoff value, 142.75 mEq/L), 0.609 (cutoff value, 3.04 mmol/L), and 0.664 (cutoff value, 140.51 mg/dL), respectively. Despite the exploratory nature of this study, we found that higher sodium, lower potassium, and higher glucose levels were predictive values for shunt-dependent hydrocephalus from postoperative day (POD) 1 to POD 12-16 after subarachnoid hemorrhage. Strict correction of electrolyte imbalance seems necessary to reduce shunt-dependent hydrocephalus. Further large studies are warranted to confirm our findings.

  9. Early variations of laboratory parameters predicting shunt-dependent hydrocephalus after subarachnoid hemorrhage

    PubMed Central

    Kim, Choong Hyun; Kim, Jae Min; Cheong, Jin Hwan; Ryu, Je il

    2017-01-01

    Background and purpose Hydrocephalus is a frequent complication following subarachnoid hemorrhage. Few studies investigated the association between laboratory parameters and shunt-dependent hydrocephalus. This study aimed to investigate the variations of laboratory parameters after subarachnoid hemorrhage. We also attempted to identify predictive laboratory parameters for shunt-dependent hydrocephalus. Methods Multiple imputation was performed to fill the missing laboratory data using Bayesian methods in SPSS. We used univariate and multivariate Cox regression analyses to calculate hazard ratios for shunt-dependent hydrocephalus based on clinical and laboratory factors. The area under the receiver operating characteristic curve was used to determine the laboratory risk values predicting shunt-dependent hydrocephalus. Results We included 181 participants with a mean age of 54.4 years. Higher sodium (hazard ratio, 1.53; 95% confidence interval, 1.13–2.07; p = 0.005), lower potassium, and higher glucose levels were associated with higher shunt-dependent hydrocephalus. The receiver operating characteristic curve analysis showed that the areas under the curve of sodium, potassium, and glucose were 0.649 (cutoff value, 142.75 mEq/L), 0.609 (cutoff value, 3.04 mmol/L), and 0.664 (cutoff value, 140.51 mg/dL), respectively. Conclusions Despite the exploratory nature of this study, we found that higher sodium, lower potassium, and higher glucose levels were predictive values for shunt-dependent hydrocephalus from postoperative day (POD) 1 to POD 12–16 after subarachnoid hemorrhage. Strict correction of electrolyte imbalance seems necessary to reduce shunt-dependent hydrocephalus. Further large studies are warranted to confirm our findings. PMID:29232410

  10. Streamlining workflow and automation to accelerate laboratory scale protein production.

    PubMed

    Konczal, Jennifer; Gray, Christopher H

    2017-05-01

    Protein production facilities are often required to produce diverse arrays of proteins for demanding methodologies including crystallography, NMR, ITC and other reagent intensive techniques. It is common for these teams to find themselves a bottleneck in the pipeline of ambitious projects. This pressure to deliver has resulted in the evolution of many novel methods to increase capacity and throughput at all stages in the pipeline for generation of recombinant proteins. This review aims to describe current and emerging options to accelerate the success of protein production in Escherichia coli. We emphasize technologies that have been evaluated and implemented in our laboratory, including innovative molecular biology and expression vectors, small-scale expression screening strategies and the automation of parallel and multidimensional chromatography. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  11. The Pathology Laboratory Act 2007 explained.

    PubMed

    Looi, Lai-Meng

    2008-06-01

    The past century has seen tremendous changes in the scope and practice of pathology laboratories in tandem with the development of the medical services in Malaysia. Major progress was made in the areas of training and specialization of pathologists and laboratory technical staff. Today the pathology laboratory services have entered the International arena, and are propelled along the wave of globalization. Many new challenges have emerged as have new players in the field. Landmark developments over the past decade include the establishment of national quality assurance programmes, the mushrooming of private pathology laboratories, the establishment of a National Accreditation Standard for medical testing laboratories based on ISO 15189, and the passing of the Pathology Laboratory Act in Parliament in mid-2007. The Pathology Laboratory Act 2007 seeks to ensure that the pathology laboratory is accountable to the public, meets required standards of practice, participates in Quality Assurance programmes, is run by qualified staff, complies with safety requirements and is subject to continuous audit. The Act is applicable to all private laboratories (stand alone or hospital) and laboratories in statutory bodies (Universities, foundations). It is not applicable to public laboratories (established and operated by the government) and side-room laboratories established in clinics of registered medical or dental practitioners for their own patients (tests as in the First and Second Schedules respectively). Tests of the Third Schedule (home test blood glucose, urine glucose, urine pregnancy test) are also exempted. The Act has 13 Parts and provides for control of the pathology laboratory through approval (to establish and maintain) and licensing (to operate or provide). The approval or license may only be issued to a sole proprietor, partnership or body corporate, and then only if the entity includes a registered medical practitioner. Details of personnel qualifications and

  12. Between and within laboratory reliability of mouse behaviour recorded in home-cage and open-field.

    PubMed

    Robinson, Lianne; Spruijt, Berry; Riedel, Gernot

    2018-04-15

    Reproducibility of behavioural findings between laboratories is difficult due to behaviour being sensitive to environmental factors and interactions with genetics. The objective of this study was to investigate reproducibility of behavioural data between laboratories using the PhenoTyper home cage observation system and within laboratory reproducibility using different lighting regimes. The ambulatory activity of C57BL/6 and DBA/2 mice was tested in PhenoTypers in two laboratories under near identical housing and testing conditions (Exp. 1). Additionally activity and anxiety were also assessed in the open-field test. Furthermore, testing in either a normal or inverted light/dark cycle was used to determine effects of lighting regime in a within-laboratory comparison in Aberdeen (Exp. 2). Using the PhenoTyper similar circadian rhythms were observed across laboratories. Higher levels of baseline and novelty-induced activity were evident in Aberdeen compared to Utrecht although strain differences were consistent between laboratories. Open field activity was also similar across laboratories whereas strain differences in anxiety were different. Within laboratory analysis of different lighting regimes revealed that behaviour of the mice was sensitive to changes in lighting. Utilisation of a home cage observation system facilitates the reproducibility of activity but not anxiety-related behaviours across laboratories by eliminating environmental factors known to influence reproducibility in standard behavioural tests. Standardisation of housing/test conditions resulted in reproducibility of home cage and open field activity but not anxiety-related phenotypes across laboratories with some behaviours more sensitive to environmental factors. Environmental factors include lighting and time of day. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. [Biosafety in laboratories concerning exposure to biological agents].

    PubMed

    Vonesch, N; Tomao, P; Di Renzi, S; Vita, S; Signorini, S

    2006-01-01

    Laboratory workers are exposed to a variety of potential occupational health hazards including those deriving from infectious materials and cultures, radiations, toxic and flammable chemicals, as well as mechanical and electrical hazard. Although all of them are significant, this paper will focus on biological hazards present in clinical and research laboratories. In fact, in spite of numerous publications, guidelines and regulations, laboratory workers are still subject to infections acquired in the course of their researches. This paper describes some aspects that include good microbiological practices (GMPs), appropriate containment equipment, practices and operational procedures to minimize workers' risk of injury or illness.

  14. Module Architecture for in Situ Space Laboratories

    NASA Technical Reports Server (NTRS)

    Sherwood, Brent

    2010-01-01

    The paper analyzes internal outfitting architectures for space exploration laboratory modules. ISS laboratory architecture is examined as a baseline for comparison; applicable insights are derived. Laboratory functional programs are defined for seven planet-surface knowledge domains. Necessary and value-added departures from the ISS architecture standard are defined, and three sectional interior architecture options are assessed for practicality and potential performance. Contemporary guidelines for terrestrial analytical laboratory design are found to be applicable to the in-space functional program. Densepacked racks of system equipment, and high module volume packing ratios, should not be assumed as the default solution for exploration laboratories whose primary activities include un-scriptable investigations and experimentation on the system equipment itself.

  15. Laboratory investigation of hypercoagulability.

    PubMed

    Francis, J L

    1998-01-01

    For many years, the laboratory investigation of patients with thrombophilia has lagged behind that of patients with bleeding diathesis. Improved understanding of the mechanisms that control and regulate coagulation, and the resultant recognition of new defects, have greatly stimulated clinical laboratory interest in this area. Assays to detect resistance to activated protein C; deficiencies of antithrombin, protein C, and protein S; and the presence of antiphospholipid antibodies are widely available and should form part of the investigation of patients that present with idiopathic thrombosis. Such a work-up will likely provide an explanation for thrombosis in 40 to 60% of patients. Abnormalities of fibrinogen and fibrinolysis may explain still more, although such defects are currently considered rare. In addition, presently unrecognized defects almost certainly exist, and the identification of such individuals will undoubtedly improve our understanding of the hemostatic mechanism. Laboratory tests to define the hypercoagulable state are continually being developed. They include whole blood coagulation and platelet function tests and novel activation markers. However, acceptance of these approaches by clinical laboratories has been slow.

  16. Kennedy's Biomedical Laboratory Makes Multi-Tasking Look Easy

    NASA Technical Reports Server (NTRS)

    Dunn, Carol Anne

    2009-01-01

    years). The lab has also actively collaborated with the US Army Institute for Surgical Research, the USAF School of Aerospace Medicine, and the USN Naval Experimental Diving Unit. Because the lab often evaluates various forms of commercial-off-the-shelf life support equipment, the laboratory works closely with private companies, both domestic and foreign. The European companies seem to be more proactive and participatory with the advancement of personal protective equipment. Because these companies have viewed the space program's unique need for advanced forms of personal protective equipment, some have responded with new designs based on the prediction that these advances will soon find markets in the commercial sector. Using much of the same skills and equipment, the laboratory also addresses physiological testing of humans by supporting flight experiments and personnel involved with ground processing. While Johnson Space Center is primarily responsible for flight experiments, the Kennedy's Biomedical Lab provides the local support. However, as stated above, there are many challenges facing KSC workers that gain the attention of this lab in the measurement of the problem and the selection and testing of countermeasures. These include respiratory protection, whole body suits, hearing protection and heat stress, among many others.

  17. Severe congenital toxoplasmosis in the United States: clinical and serologic findings in untreated infants.

    PubMed

    Olariu, Tudor Rares; Remington, Jack S; McLeod, Rima; Alam, Ambereen; Montoya, Jose G

    2011-12-01

    Congenital toxoplasmosis can cause significant neurologic manifestations and other untoward sequelae. The Palo Alto Medical Foundation Toxoplasma Serology Laboratory database was searched for data on infants 0 to 180 days old, in whom congenital toxoplasmosis had been confirmed and who had been tested for Toxoplasma gondii-specific immunoglobulin G (IgG), IgM, and IgA antibodies, between 1991 and 2005. Their clinical findings were confirmed at the National Collaborative Chicago-based Congenital Toxoplasmosis Study center. We reviewed available clinical data and laboratory profiles of 164 infants with congenital toxoplasmosis whose mothers had not been treated for the parasite during gestation. One or more severe clinical manifestations of congenital toxoplasmosis were reported in 84% of the infants and included eye disease (92.2%), brain calcifications (79.6%), and hydrocephalus (67.7%). In 61.6% of the infants, eye disease, brain calcifications, and hydrocephalus were present concurrently. T. gondii-specific IgM, IgA, and IgE antibodies were demonstrable in 86.6%, 77.4%, and 40.2% of the infants, respectively. Testing for IgM and IgA antibodies increased the sensitivity of making the diagnosis of congenital toxoplasmosis to 93% compared with testing for IgM or IgA individually. IgM and IgA antibodies were still present in 43.9% of infants diagnosed between 1 and 6 months of life. Our study reveals that severe clinical signs of congenital toxoplasmosis including hydrocephalus, eye disease, or intracranial calcifications occurred in 85% infants whose sera were referred to our reference Toxoplasma Serology Laboratory during a period of 15 years. Laboratory tests, including serologic and polymerase chain reaction tests, were critical for diagnosis in the infants. Our results contrast remarkably with those of European investigators who rarely observe severe clinical signs in infants with congenital toxoplasmosis.

  18. Chemistry Graduate Teaching Assistants' Experiences in Academic Laboratories and Development of a Teaching Self-image

    NASA Astrophysics Data System (ADS)

    Gatlin, Todd Adam

    Graduate teaching assistants (GTAs) play a prominent role in chemistry laboratory instruction at research based universities. They teach almost all undergraduate chemistry laboratory courses. However, their role in laboratory instruction has often been overlooked in educational research. Interest in chemistry GTAs has been placed on training and their perceived expectations, but less attention has been paid to their experiences or their potential benefits from teaching. This work was designed to investigate GTAs' experiences in and benefits from laboratory instructional environments. This dissertation includes three related studies on GTAs' experiences teaching in general chemistry laboratories. Qualitative methods were used for each study. First, phenomenological analysis was used to explore GTAs' experiences in an expository laboratory program. Post-teaching interviews were the primary data source. GTAs experiences were described in three dimensions: doing, knowing, and transferring. Gains available to GTAs revolved around general teaching skills. However, no gains specifically related to scientific development were found in this laboratory format. Case-study methods were used to explore and illustrate ways GTAs develop a GTA self-image---the way they see themselves as instructors. Two general chemistry laboratory programs that represent two very different instructional frameworks were chosen for the context of this study. The first program used a cooperative project-based approach. The second program used weekly, verification-type activities. End of the semester interviews were collected and served as the primary data source. A follow-up case study of a new cohort of GTAs in the cooperative problem-based laboratory was undertaken to investigate changes in GTAs' self-images over the course of one semester. Pre-semester and post-semester interviews served as the primary data source. Findings suggest that GTAs' construction of their self-image is shaped through the

  19. Implementation of a National Reference Laboratory for Buruli Ulcer Disease in Togo

    PubMed Central

    Badziklou, Kossi; Halatoko, Wemboo Afiwa; Maman, Issaka; Vogel, Felix; Bidjada, Bawimodom; Awoussi, Koffi Somenou; Piten, Ebekalisai; Helfrich, Kerstin; Mengele, Carolin; Nitschke, Jörg; Amekuse, Komi; Wiedemann, Franz Xaver; Diefenhardt, Adolf; Kobara, Basile; Herbinger, Karl–Heinz; Kere, Abiba Banla; Prince-David, Mireille; Löscher, Thomas; Bretzel, Gisela

    2013-01-01

    Background In a previous study PCR analysis of clinical samples from suspected cases of Buruli ulcer disease (BUD) from Togo and external quality assurance (EQA) for local microscopy were conducted at an external reference laboratory in Germany. The relatively poor performance of local microscopy as well as effort and time associated with shipment of PCR samples necessitated the implementation of stringent EQA measures and availability of local laboratory capacity. This study describes the approach to implementation of a national BUD reference laboratory in Togo. Methodology Large scale outreach activities accompanied by regular training programs for health care professionals were conducted in the regions “Maritime” and “Central,” standard operating procedures defined all processes in participating laboratories (regional, national and external reference laboratories) as well as the interaction between laboratories and partners in the field. Microscopy was conducted at regional level and slides were subjected to EQA at national and external reference laboratories. For PCR analysis, sample pairs were collected and subjected to a dry-reagent-based IS2404-PCR (DRB-PCR) at national level and standard IS2404 PCR followed by IS2404 qPCR analysis of negative samples at the external reference laboratory. Principal Findings The inter-laboratory concordance rates for microscopy ranged from 89% to 94%; overall, microscopy confirmed 50% of all suspected BUD cases. The inter-laboratory concordance rate for PCR was 96% with an overall PCR case confirmation rate of 78%. Compared to a previous study, the rate of BUD patients with non-ulcerative lesions increased from 37% to 50%, the mean duration of disease before clinical diagnosis decreased significantly from 182.6 to 82.1 days among patients with ulcerative lesions, and the percentage of category III lesions decreased from 30.3% to 19.2%. Conclusions High inter-laboratory concordance rates as well as case confirmation

  20. LANGUAGE LABORATORY SPECIFICATIONS. A PROCUREMENT GUIDE FOR THE PURCHASE OF LANGUAGE LABORATORY INSTALLATIONS IN WISCONSIN, NDEA, TITLE III.

    ERIC Educational Resources Information Center

    GRITTNER, FRANK; PAVLAT, RUSSELL

    THE KNOWLEDGE ACCUMULATED FROM THE EXPERIENCE OF INSTALLING MANY LANGUAGE LABORATORIES UNDER THE TITLE III, NDEA PROGRAM FORMS THE BASIS FOR THE GUIDELINES PRESENTED IN THIS BULLETIN. THE DOCUMENT INCLUDES A SUMMARY OF CONDITIONS DESIRABLE PRIOR TO THE PURCHASE OF A LABORATORY, SAMPLE SPECIFICATIONS FOR EACH COMPONENT OF THE LAB, SPECIFICATIONS…

  1. Multidimensional Screening as a Pharmacology Laboratory Experience.

    ERIC Educational Resources Information Center

    Malone, Marvin H.; And Others

    1979-01-01

    A multidimensional pharmacodynamic screening experiment that addresses drug interaction is included in the pharmacology-toxicology laboratory experience of pharmacy students at the University of the Pacific. The student handout with directions for the procedure is reproduced, drug compounds tested are listed, and laboratory evaluation results are…

  2. Some new tests at the Gottingen laboratory

    NASA Technical Reports Server (NTRS)

    1921-01-01

    The tests at the Gottingen laboratory included: friction tests on a surface treated with omelette, verification tests on the M.V.A. 356 wing, and comparative tests of wing no. 36 at the Eiffel laboratory. The examination of all these experiments leads to the belief that, at large incidences, the speeds registered by the suction manometer of the testing chamber of the Eiffel laboratory wind tunnel are, owing to pressure drop, greater than the actual speeds. Therefore, the values of k(sub x) and k(sub y) measured at the Eiffel laboratory at large incidences are too low.

  3. Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 1. Biosafety Level 4 Suit Laboratory Suite Entry and Exit Procedures

    PubMed Central

    Janosko, Krisztina; Holbrook, Michael R.; Adams, Ricky; Barr, Jason; Bollinger, Laura; Newton, Je T'aime; Ntiforo, Corrie; Coe, Linda; Wada, Jiro; Pusl, Daniela; Jahrling, Peter B.; Kuhn, Jens H.; Lackemeyer, Matthew G.

    2016-01-01

    Biosafety level 4 (BSL-4) suit laboratories are specifically designed to study high-consequence pathogens for which neither infection prophylaxes nor treatment options exist. The hallmarks of these laboratories are: custom-designed airtight doors, dedicated supply and exhaust airflow systems, a negative-pressure environment, and mandatory use of positive-pressure (“space”) suits. The risk for laboratory specialists working with highly pathogenic agents is minimized through rigorous training and adherence to stringent safety protocols and standard operating procedures. Researchers perform the majority of their work in BSL-2 laboratories and switch to BSL-4 suit laboratories when work with a high-consequence pathogen is required. Collaborators and scientists considering BSL-4 projects should be aware of the challenges associated with BSL-4 research both in terms of experimental technical limitations in BSL-4 laboratory space and the increased duration of such experiments. Tasks such as entering and exiting the BSL-4 suit laboratories are considerably more complex and time-consuming compared to BSL-2 and BSL-3 laboratories. The focus of this particular article is to address basic biosafety concerns and describe the entrance and exit procedures for the BSL-4 laboratory at the NIH/NIAID Integrated Research Facility at Fort Detrick. Such procedures include checking external systems that support the BSL-4 laboratory, and inspecting and donning positive-pressure suits, entering the laboratory, moving through air pressure-resistant doors, and connecting to air-supply hoses. We will also discuss moving within and exiting the BSL-4 suit laboratories, including using the chemical shower and removing and storing positive-pressure suits. PMID:27768063

  4. Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 1. Biosafety Level 4 Suit Laboratory Suite Entry and Exit Procedures.

    PubMed

    Janosko, Krisztina; Holbrook, Michael R; Adams, Ricky; Barr, Jason; Bollinger, Laura; Newton, Je T'aime; Ntiforo, Corrie; Coe, Linda; Wada, Jiro; Pusl, Daniela; Jahrling, Peter B; Kuhn, Jens H; Lackemeyer, Matthew G

    2016-10-03

    Biosafety level 4 (BSL-4) suit laboratories are specifically designed to study high-consequence pathogens for which neither infection prophylaxes nor treatment options exist. The hallmarks of these laboratories are: custom-designed airtight doors, dedicated supply and exhaust airflow systems, a negative-pressure environment, and mandatory use of positive-pressure ("space") suits. The risk for laboratory specialists working with highly pathogenic agents is minimized through rigorous training and adherence to stringent safety protocols and standard operating procedures. Researchers perform the majority of their work in BSL-2 laboratories and switch to BSL-4 suit laboratories when work with a high-consequence pathogen is required. Collaborators and scientists considering BSL-4 projects should be aware of the challenges associated with BSL-4 research both in terms of experimental technical limitations in BSL-4 laboratory space and the increased duration of such experiments. Tasks such as entering and exiting the BSL-4 suit laboratories are considerably more complex and time-consuming compared to BSL-2 and BSL-3 laboratories. The focus of this particular article is to address basic biosafety concerns and describe the entrance and exit procedures for the BSL-4 laboratory at the NIH/NIAID Integrated Research Facility at Fort Detrick. Such procedures include checking external systems that support the BSL-4 laboratory, and inspecting and donning positive-pressure suits, entering the laboratory, moving through air pressure-resistant doors, and connecting to air-supply hoses. We will also discuss moving within and exiting the BSL-4 suit laboratories, including using the chemical shower and removing and storing positive-pressure suits.

  5. National Survey on Internal Quality Control for HbA(1c) Analytical Instruments in 331 Hospital Laboratories of China.

    PubMed

    Zeng, Rong; Wang, Wei; Zhao, Haijian; Fei, Yang; Wang, Zhiguo

    2015-01-01

    The narrow gap of HbA1 value of mass fraction between "normal" (< 6.0%) and "diabetes" (≥ 6.5%) necessitates tight control of inter-assay standardization, assay precision, and trueness. This survey was initiated to obtain knowledge of the current situation of internal quality control (IQC) practice for HbA(1c) in China and find out the most appropriate quality specifications. Data of IQC for HbA(1c) in 331 institutions participating in the national proficiency testing (PT) programs in China were evaluated using four levels of quality specifications, and the percentages of laboratories meeting the quality requirement were calculated to find out the most appropriate quality specifications for control materials of HbA(1c) in China. The IQC data varied vastly among 331 clinical laboratories in China. The measurement of control materials covered a wide range from 4.52% to 12.24% (inter-quartile range) and there were significant differences among the CVs of different methods, including LPLC, CE-HPLC, AC-HPLC, immunoturbidimetry, and others. Among the four main methods, CE-HPLC and AC-HPLC achieved a better precision. As we can see, the performance of laboratories for HbA(1c) has yet to be improved. Clinical laboratories in China should improve their performance with a stricter imprecision criteria.

  6. Light and the laboratory mouse.

    PubMed

    Peirson, Stuart N; Brown, Laurence A; Pothecary, Carina A; Benson, Lindsay A; Fisk, Angus S

    2018-04-15

    Light exerts widespread effects on physiology and behaviour. As well as the widely-appreciated role of light in vision, light also plays a critical role in many non-visual responses, including regulating circadian rhythms, sleep, pupil constriction, heart rate, hormone release and learning and memory. In mammals, responses to light are all mediated via retinal photoreceptors, including the classical rods and cones involved in vision as well as the recently identified melanopsin-expressing photoreceptive retinal ganglion cells (pRGCs). Understanding the effects of light on the laboratory mouse therefore depends upon an appreciation of the physiology of these retinal photoreceptors, including their differing sens itivities to absolute light levels and wavelengths. The signals from these photoreceptors are often integrated, with different responses involving distinct retinal projections, making generalisations challenging. Furthermore, many commonly used laboratory mouse strains carry mutations that affect visual or non-visual physiology, ranging from inherited retinal degeneration to genetic differences in sleep and circadian rhythms. Here we provide an overview of the visual and non-visual systems before discussing practical considerations for the use of light for researchers and animal facility staff working with laboratory mice. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  7. Quality Assurance of RNA Expression Profiling in Clinical Laboratories

    PubMed Central

    Tang, Weihua; Hu, Zhiyuan; Muallem, Hind; Gulley, Margaret L.

    2012-01-01

    RNA expression profiles are increasingly used to diagnose and classify disease, based on expression patterns of as many as several thousand RNAs. To ensure quality of expression profiling services in clinical settings, a standard operating procedure incorporates multiple quality indicators and controls, beginning with preanalytic specimen preparation and proceeding thorough analysis, interpretation, and reporting. Before testing, histopathological examination of each cellular specimen, along with optional cell enrichment procedures, ensures adequacy of the input tissue. Other tactics include endogenous controls to evaluate adequacy of RNA and exogenous or spiked controls to evaluate run- and patient-specific performance of the test system, respectively. Unique aspects of quality assurance for array-based tests include controls for the pertinent outcome signatures that often supersede controls for each individual analyte, built-in redundancy for critical analytes or biochemical pathways, and software-supported scrutiny of abundant data by a laboratory physician who interprets the findings in a manner facilitating appropriate medical intervention. Access to high-quality reagents, instruments, and software from commercial sources promotes standardization and adoption in clinical settings, once an assay is vetted in validation studies as being analytically sound and clinically useful. Careful attention to the well-honed principles of laboratory medicine, along with guidance from government and professional groups on strategies to preserve RNA and manage large data sets, promotes clinical-grade assay performance. PMID:22020152

  8. An audit of Cryptosporidium and Giardia detection in Scottish National Health Service Diagnostic Microbiology Laboratories.

    PubMed

    Alexander, C L; Currie, S; Pollock, K; Smith-Palmer, A; Jones, B L

    2017-06-01

    Giardia duodenalis and Cryptosporidium species are protozoan parasites capable of causing gastrointestinal disease in humans and animals through the ingestion of infective faeces. Whereas Cryptosporidium species can be acquired locally or through foreign travel, there is the mis-conception that giardiasis is considered to be largely travel-associated, which results in differences in laboratory testing algorithms. In order to determine the level of variation in testing criteria and detection methods between diagnostic laboratories for both pathogens across Scotland, an audit was performed. Twenty Scottish diagnostic microbiology laboratories were invited to participate with questions on sample acceptance criteria, testing methods, testing rates and future plans for pathogen detection. Reponses were received from 19 of the 20 laboratories representing each of the 14 territorial Health Boards. Detection methods varied between laboratories with the majority performing microscopy, one using a lateral flow immunochromatographic antigen assay, another using a manually washed plate-based enzyme immunoassay (EIA) and one laboratory trialling a plate-based EIA automated with an EIA plate washer. Whereas all laboratories except one screened every stool for Cryptosporidium species, an important finding was that significant variation in the testing algorithm for detecting Giardia was noted with only four laboratories testing all diagnostic stools. The most common criteria were 'travel history' (11 laboratories) and/or 'when requested' (14 laboratories). Despite only a small proportion of stools being examined in 15 laboratories for Giardia (2%-18% of the total number of stools submitted), of interest is the finding that a higher positivity rate was observed for Giardia than Cryptosporidium in 10 of these 15 laboratories. These findings highlight that the underreporting of Giardia in Scotland is likely based on current selection and testing algorithms.

  9. Effective utilization of clinical laboratories.

    PubMed

    Murphy, J; Henry, J B

    1978-11-01

    Effective utilization of clinical laboratories requires that underutilization, overutilization, and malutilization be appreciated and eliminated or reduced. Optimal patient care service, although subjective to a major extent, is reflected in terms of outcome and cost. Increased per diem charges, reduced hospital stay, and increased laboratory workload over the past decade all require each laboratory to examine its internal operations to achieve economy and efficiency as well as maximal effectiveness. Increased research and development, an active managerial role on the part of pathologists, internal self-assessment, and an aggressive response to sophisticated scientific and clinical laboratory data base requirements are not only desirable but essential. The importance of undergraduate and graduate medical education in laboratory medicine to insure understanding as well as effective utilization is stressed. The costs and limitations as well as the accuracy, precision, sensitivity, specificity, and pitfalls of measurements and examinations must also be fully appreciated. Medical malpractice and defensive medicine and the use of critical values, emergency and routine services, and an active clinical role by the pathologist are of the utmost value in assuring effective utilization of the laboratory. A model for the optimal use of the laboratory including economy and efficiency has been achieved in the blood bank in regard to optimal hemotherapy for elective surgery, assuring superior patient care in a cost effective and safe manner.

  10. Sonic-boom-induced building structure responses including damage.

    NASA Technical Reports Server (NTRS)

    Clarkson, B. L.; Mayes, W. H.

    1972-01-01

    Concepts of sonic-boom pressure loading of building structures and the associated responses are reviewed, and results of pertinent theoretical and experimental research programs are summarized. The significance of sonic-boom load time histories, including waveshape effects, are illustrated with the aid of simple structural elements such as beams and plates. Also included are discussions of the significance of such other phenomena as three-dimensional loading effects, air cavity coupling, multimodal responses, and structural nonlinearities. Measured deflection, acceleration, and strain data from laboratory models and full-scale building tests are summarized, and these data are compared, where possible, with predicted values. Damage complaint and claim experience due both to controlled and uncontrolled supersonic flights over communities are summarized with particular reference to residential, commercial, and historic buildings. Sonic-boom-induced building responses are compared with those from other impulsive loadings due to natural and cultural events and from laboratory simulation tests.

  11. [Status of the clinical laboratory in the mandatory postgraduate medical training system. (1) Report from a laboratory technologist].

    PubMed

    Nishikawa, Yoko

    2006-06-01

    According to a new system for postgraduate clinical training, 33 medical trainees have been accepted for the past two years at Osaka General Medical Center. Before practicing clinical medicine in each division by a super-rotated table, orientation is scheduled for 5 days to master the basic systems indispensable to the hospital. In this orientation, training in laboratory medicine is performed for 7 hours (3.5 hours for 2 days). Trainees are divided into 4 groups and learn emergency tests of chemistry, hematology and urinalysis, blood transfusion, physiology and microbiology for 60 min each. Laboratory technologists instruct the trainees to gain the basic skills. The main contents are blood gas measuring in chemistry, sample preparation in hematology and urinalysis, taking each other's ECG, ordering blood products for transfusion, serologic study of infectious diseases, and Gram stain in microbiology. Although it is difficult to find time for routine analysis and instructing trainees in the clinical laboratory, it is a suitable opportunity for revision, also for laboratory technologists, and for communication to discuss clinical matters.

  12. [Assessment of the quality of laboratory diagnosis of intestinal parasitic diseases by the laboratories participating in the Federal System of External Quality Assessment of Clinical Laboratory Testing].

    PubMed

    Malakhov, V N; Dovgalev, A S; Astanina, S Iu; Serdiuk, A P

    2014-01-01

    In 2010-2013, the quality of microscopic detection of the causative agents ofparasitic diseases in the feces has been assessed by the specialists of the laboratories of the therapeutic-and-prophylactic institutions (TPIs) and Hygiene and Epidemiology Centers, Russian Inspectorate for the Protection of Consumer Rights and Human Welfare, which are participants of the Federal System of External Quality Assessment of Clinical Laboratory Testing. Thirty-two specimens containing 16 species of human helminths and 4 species of enteric protozoa in different combinations were examined. The findings suggest that the quality of microscopic detection of the causative agents of parasitic diseases is low in the laboratories of health care facilities and that the specialists of the laboratories of TPIs and Hygiene and Epidemiology Centers, Russian Inspectorate for the Protection of Consumer Rights and Human Welfare, do not not possess the knowledge and skills necessary to make a laboratory diagnosis of helminths and enteric protozoa. The average detection rates of helminths and protozoa were at a level of 64 and 36%, respectively. The correct results showed that the proportion of helminths and protozoa were 94.5 and 5.5%, respectively. According to the biological and epidemiological classification of helminths, there were higher detection rates for contact group parasites (Enterobius vermicularis and Hymenolepis nana) and geohelminths (Ascaris, Trichuris trichiura, and others). Biohelminths (Opisthorchis, tapeworms, and others) Were detectable slightly worse.

  13. Wiki Laboratory Notebooks: Supporting Student Learning in Collaborative Inquiry-Based Laboratory Experiments

    ERIC Educational Resources Information Center

    Lawrie, Gwendolyn Angela; Grøndahl, Lisbeth; Boman, Simon; Andrews, Trish

    2016-01-01

    Recent examples of high-impact teaching practices in the undergraduate chemistry laboratory that include course-based undergraduate research experiences and inquiry-based experiments require new approaches to assessing individual student learning outcomes. Instructors require tools and strategies that can provide them with insight into individual…

  14. Mistakes in a stat laboratory: types and frequency.

    PubMed

    Plebani, M; Carraro, P

    1997-08-01

    Application of Total Quality Management concepts to laboratory testing requires that the total process, including preanalytical and postanalytical phases, be managed so as to reduce or, ideally, eliminate all defects within the process itself. Indeed a "mistake" can be defined as any defect during the entire testing process, from ordering tests to reporting results. We evaluated the frequency and types of mistakes found in the "stat" section of the Department of Laboratory Medicine of the University-Hospital of Padova by monitoring four different departments (internal medicine, nephrology, surgery, and intensive care unit) for 3 months. Among a total of 40490 analyses, we identified 189 laboratory mistakes, a relative frequency of 0.47%. The distribution of mistakes was: preanalytical 68.2%, analytical 13.3%, and postanalytical 18.5%. Most of the laboratory mistakes (74%) did not affect patients' outcome. However, in 37 patients (19%), laboratory mistakes were associated with further inappropriate investigations, thus resulting in an unjustifiable increase in costs. Moreover, in 12 patients (6.4%) laboratory mistakes were associated with inappropriate care or inappropriate modification of therapy. The promotion of quality control and continuous improvement of the total testing process, including pre- and postanalytical phases, seems to be a prerequisite for an effective laboratory service.

  15. Well Wishes: A Case on Septic Systems and Well Water Requiring In-Depth Analysis and Including Optional Laboratory Experiments

    ERIC Educational Resources Information Center

    Walczak, Mary M.; Lantz, Juliette M.

    2004-01-01

    The case of Well Wishes involves students in a thorough examination of the interaction among nitrogen-composed species in the septic systems and well water, which helps to clean household water. The case supports the attainment of five goals for students, and can be analyzed through classroom discussions or laboratory experiments.

  16. 46 CFR 188.10-11 - Chemistry laboratory.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Chemistry laboratory. 188.10-11 Section 188.10-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS GENERAL PROVISIONS Definition of Terms Used in This Subchapter § 188.10-11 Chemistry laboratory. This term includes...

  17. 46 CFR 188.10-11 - Chemistry laboratory.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Chemistry laboratory. 188.10-11 Section 188.10-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS GENERAL PROVISIONS Definition of Terms Used in This Subchapter § 188.10-11 Chemistry laboratory. This term includes...

  18. 46 CFR 188.10-11 - Chemistry laboratory.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Chemistry laboratory. 188.10-11 Section 188.10-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS GENERAL PROVISIONS Definition of Terms Used in This Subchapter § 188.10-11 Chemistry laboratory. This term includes...

  19. 46 CFR 188.10-11 - Chemistry laboratory.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Chemistry laboratory. 188.10-11 Section 188.10-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS GENERAL PROVISIONS Definition of Terms Used in This Subchapter § 188.10-11 Chemistry laboratory. This term includes...

  20. 46 CFR 188.10-11 - Chemistry laboratory.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Chemistry laboratory. 188.10-11 Section 188.10-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS GENERAL PROVISIONS Definition of Terms Used in This Subchapter § 188.10-11 Chemistry laboratory. This term includes...

  1. Laboratory testing in primary care: A systematic review of health IT impacts.

    PubMed

    Maillet, Éric; Paré, Guy; Currie, Leanne M; Raymond, Louis; Ortiz de Guinea, Ana; Trudel, Marie-Claude; Marsan, Josianne

    2018-08-01

    Laboratory testing in primary care is a fundamental process that supports patient management and care. Any breakdown in the process may alter clinical information gathering and decision-making activities and can lead to medical errors and potential adverse outcomes for patients. Various information technologies are being used in primary care with the goal to support the process, maximize patient benefits and reduce medical errors. However, the overall impact of health information technologies on laboratory testing processes has not been evaluated. To synthesize the positive and negative impacts resulting from the use of health information technology in each phase of the laboratory 'total testing process' in primary care. We conducted a systematic review. Databases including Medline, PubMed, CINAHL, Web of Science and Google Scholar were searched. Studies eligible for inclusion reported empirical data on: 1) the use of a specific IT system, 2) the impacts of the systems to support the laboratory testing process, and were conducted in 3) primary care settings (including ambulatory care and primary care offices). Our final sample consisted of 22 empirical studies which were mapped to a framework that outlines the phases of the laboratory total testing process, focusing on phases where medical errors may occur. Health information technology systems support several phases of the laboratory testing process, from ordering the test to following-up with patients. This is a growing field of research with most studies focusing on the use of information technology during the final phases of the laboratory total testing process. The findings were largely positive. Positive impacts included easier access to test results by primary care providers, reduced turnaround times, and increased prescribed tests based on best practice guidelines. Negative impacts were reported in several studies: paper-based processes employed in parallel to the electronic process increased the potential

  2. [Standardization of terminology in laboratory medicine I].

    PubMed

    Yoon, Soo Young; Yoon, Jong Hyun; Min, Won Ki; Lim, Hwan Sub; Song, Junghan; Chae, Seok Lae; Lee, Chang Kyu; Kwon, Jung Ah; Lee, Kap No

    2007-04-01

    Standardization of medical terminology is essential for data transmission between health-care institutions or clinical laboratories and for maximizing the benefits of information technology. Purpose of our study was to standardize the medical terms used in the clinical laboratory, such as test names, units, terms used in result descriptions, etc. During the first year of the study, we developed a standard database of concept names for laboratory terms, which covered the terms used in government health care centers, their branch offices, and primary health care units. Laboratory terms were collected from the electronic data interchange (EDI) codes from National Health Insurance Corporation (NHIC), Logical Observation Identifier Names and Codes (LOINC) database, community health centers and their branch offices, and clinical laboratories of representative university medical centers. For standard expression, we referred to the English-Korean/ Korean-English medical dictionary of Korean Medical Association and the rules for foreign language translation. Programs for mapping between LOINC DB and EDI code and for translating English to Korean were developed. A Korean standard laboratory terminology database containing six axial concept names such as components, property, time aspect, system (specimen), scale type, and method type was established for 7,508 test observations. Short names and a mapping table for EDI codes and Unified Medical Language System (UMLS) were added. Synonym tables for concept names, words used in the database, and six axial terms were prepared to make it easier to find the standard terminology with common terms used in the field of laboratory medicine. Here we report for the first time a Korean standard laboratory terminology database for test names, result description terms, result units covering most laboratory tests in primary healthcare centers.

  3. [The future of clinical laboratory database management system].

    PubMed

    Kambe, M; Imidy, D; Matsubara, A; Sugimoto, Y

    1999-09-01

    To assess the present status of the clinical laboratory database management system, the difference between the Clinical Laboratory Information System and Clinical Laboratory System was explained in this study. Although three kinds of database management systems (DBMS) were shown including the relational model, tree model and network model, the relational model was found to be the best DBMS for the clinical laboratory database based on our experience and developments of some clinical laboratory expert systems. As a future clinical laboratory database management system, the IC card system connected to an automatic chemical analyzer was proposed for personal health data management and a microscope/video system was proposed for dynamic data management of leukocytes or bacteria.

  4. The Point-of-Care Laboratory in Clinical Microbiology

    PubMed Central

    Michel-Lepage, Audrey; Boyer, Sylvie; Raoult, Didier

    2016-01-01

    SUMMARY Point-of-care (POC) laboratories that deliver rapid diagnoses of infectious diseases were invented to balance the centralization of core laboratories. POC laboratories operate 24 h a day and 7 days a week to provide diagnoses within 2 h, largely based on immunochromatography and real-time PCR tests. In our experience, these tests are conveniently combined into syndrome-based kits that facilitate sampling, including self-sampling and test operations, as POC laboratories can be operated by trained operators who are not necessarily biologists. POC laboratories are a way of easily providing clinical microbiology testing for populations distant from laboratories in developing and developed countries and on ships. Modern Internet connections enable support from core laboratories. The cost-effectiveness of POC laboratories has been established for the rapid diagnosis of tuberculosis and sexually transmitted infections in both developed and developing countries. PMID:27029593

  5. Instrument Synthesis and Analysis Laboratory

    NASA Technical Reports Server (NTRS)

    Wood, H. John

    2004-01-01

    The topics addressed in this viewgraph presentation include information on 1) Historic instruments at Goddard; 2) Integrated Design Capability at Goddard; 3) The Instrument Synthesis and Analysis Laboratory (ISAL).

  6. Safety in the Chemical Laboratory

    ERIC Educational Resources Information Center

    Steere, Norman V., Ed.

    1973-01-01

    Suggests laboratory instructors preserve the necessary evidence after an incident in classroom. Included is a checklist for gathering evidence that trial lawyers will need to present defense adequately. (CC)

  7. Biomedical engineering at Sandia National Laboratories

    NASA Astrophysics Data System (ADS)

    Zanner, Mary Ann

    1994-12-01

    The potential exists to reduce or control some aspects of the U.S. health care expenditure without compromising health care delivery by developing carefully selected technologies which impact favorably on the health care system. A focused effort to develop such technologies is underway at Sandia National Laboratories. As a DOE National Laboratory, Sandia possesses a wealth of engineering and scientific expertise that can be readily applied to this critical national need. Appropriate mechanisms currently exist to allow transfer of technology from the laboratory to the private sector. Sandia's Biomedical Engineering Initiative addresses the development of properly evaluated, cost-effective medical technologies through team collaborations with the medical community. Technology development is subjected to certain criteria including wide applicability, earlier diagnoses, increased efficiency, cost-effectiveness and dual-use. Examples of Sandia's medical technologies include a noninvasive blood glucose sensor, computer aided mammographic screening, noninvasive fetal oximetry and blood gas measurement, burn diagnostics and laser debridement, telerobotics and ultrasonic scanning for prosthetic devices. Sandia National Laboratories has the potential to aid in directing medical technology development efforts which emphasize health care needs, earlier diagnosis, cost containment and improvement of the quality of life.

  8. The gross anatomy laboratory: a novel venue for critical thinking and interdisciplinary teaching in dental education.

    PubMed

    Rowland, Kevin C; Joy, Anita

    2015-03-01

    Reports on the status of dental education have concluded that there is a need for various types of curricular reform, making recommendations that include better integration of basic, behavioral, and clinical sciences, increased case-based teaching, emphasis on student-driven learning, and creation of lifelong learners. Dental schools faced with decreasing contact hours, increasing teaching material, and technological advancements have experimented with alternate curricular strategies. At Southern Illinois University School of Dental Medicine, curricular changes have begun with a series of integrated biomedical sciences courses. During the process of planning and implementing the integrated courses, a novel venue-the gross anatomy laboratory-was used to introduce all Year 1 students to critical thinking, self-directed learning, and the scientific method. The venture included student-driven documentation of anatomical variations encountered in the laboratory using robust scientific methods, thorough literature review, and subsequent presentation of findings in peer review settings. Students responded positively, with over 75% agreeing the experience intellectually challenged them. This article describes the process of re-envisioning the gross anatomy laboratory as an effective venue for small group-based, student-driven projects that focus on key pedagogical concepts to encourage the development of lifelong learners.

  9. The science of laboratory and project management in regulated bioanalysis.

    PubMed

    Unger, Steve; Lloyd, Thomas; Tan, Melvin; Hou, Jingguo; Wells, Edward

    2014-05-01

    Pharmaceutical drug development is a complex and lengthy process, requiring excellent project and laboratory management skills. Bioanalysis anchors drug safety and efficacy with systemic and site of action exposures. Development of scientific talent and a willingness to innovate or adopt new technology is essential. Taking unnecessary risks, however, should be avoided. Scientists must strategically assess all risks and find means to minimize or negate them. Laboratory Managers must keep abreast of ever-changing technology. Investments in instrumentation and laboratory design are critical catalysts to efficiency and safety. Matrix management requires regular communication between Project Managers and Laboratory Managers. When properly executed, it aligns the best resources at the right times for a successful outcome. Attention to detail is a critical aspect that separates excellent laboratories. Each assay is unique and requires attention in its development, validation and execution. Methods, training and facilities are the foundation of a bioanalytical laboratory.

  10. Laboratory-associated infections and biosafety.

    PubMed Central

    Sewell, D L

    1995-01-01

    An estimated 500,000 laboratory workers in the United States are at risk of exposure to infectious agents that cause disease ranging from inapparent to life-threatening infections, but the precise risk to a given worker unknown. The emergence of human immunodeficiency virus and hantavirus, the continuing problem of hepatitis B virus, and the reemergence of Mycobacterium tuberculosis have renewed interest in biosafety for the employees of laboratories and health care facilities. This review examines the history, the causes, and the methods for prevention of laboratory-associated infections. The initial step in a biosafety program is the assessment of risk to the employee. Risk assessment guidelines include the pathogenicity of the infectious agent, the method of transmission, worker-related risk factors, the source and route of infection, and the design of the laboratory facility. Strategies for the prevention and management of laboratory-associated infections are based on the containment of the infectious agent by physical separation from the laboratory worker and the environment, employee education about the occupational risks, and availability of an employee health program. Adherence to the biosafety guidelines mandated or proposed by various governmental and accrediting agencies reduces the risk of an occupational exposure to infectious agents handled in the workplace. PMID:7553572

  11. Landscape Structure Shapes Habitat Finding Ability in a Butterfly

    PubMed Central

    Öckinger, Erik; Van Dyck, Hans

    2012-01-01

    Land-use intensification and habitat fragmentation is predicted to impact on the search strategies animals use to find habitat. We compared the habitat finding ability between populations of the speckled wood butterfly (Pararge aegeria L.) from landscapes that differ in degree of habitat fragmentation. Naïve butterflies reared under standardized laboratory conditions but originating from either fragmented agricultural landscapes or more continuous forested landscapes were released in the field, at fixed distances from a target habitat patch, and their flight paths were recorded. Butterflies originating from fragmented agricultural landscapes were better able to find a woodlot habitat from a distance compared to conspecifics from continuous forested landscapes. To manipulate the access to olfactory information, a subset of individuals from both landscape types were included in an antennae removal experiment. This confirmed the longer perceptual range for butterflies from agricultural landscapes and indicated the significance of both visual and olfactory information for orientation towards habitat. Our results are consistent with selection for increased perceptual range in fragmented landscapes to reduce dispersal costs. An increased perceptual range will alter the functional connectivity and thereby the chances for population persistence for the same level of structural connectivity in a fragmented landscape. PMID:22870227

  12. Adaptive Optics at Lawrence Livermore National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gavel, D T

    2003-03-10

    Adaptive optics enables high resolution imaging through the atmospheric by correcting for the turbulent air's aberrations to the light waves passing through it. The Lawrence Livermore National Laboratory for a number of years has been at the forefront of applying adaptive optics technology to astronomy on the world's largest astronomical telescopes, in particular at the Keck 10-meter telescope on Mauna Kea, Hawaii. The technology includes the development of high-speed electrically driven deformable mirrors, high-speed low-noise CCD sensors, and real-time wavefront reconstruction and control hardware. Adaptive optics finds applications in many other areas where light beams pass through aberrating media andmore » must be corrected to maintain diffraction-limited performance. We describe systems and results in astronomy, medicine (vision science), and horizontal path imaging, all active programs in our group.« less

  13. Incidence, clinical features, laboratory findings and outcome of patients with multiple myeloma presenting with extramedullary relapse.

    PubMed

    Papanikolaou, Xenofon; Repousis, Panagiotis; Tzenou, Tatiana; Maltezas, Dimitris; Kotsopoulou, Maria; Megalakaki, Katerina; Angelopoulou, Maria; Dimitrakoloulou, Elektra; Koulieris, Efstathios; Bartzis, Vassiliki; Pangalis, Gerasimos; Panayotidis, Panagiotis; Kyrtsonis, Marie-Christine

    2013-07-01

    Extramedullary plasmacytomas constitute a rare and not well studied subset of multiple myeloma (MM) relapses. We report the incidence, clinical-laboratory features and outcome of patients with MM and extramedullary relapse (ExMeR). A total of 303 patients with symptomatic MM were recorded in a 13-year period in two institutions. Twenty-eight cases of ExMeR (9%) were recorded. There was an increased frequency of elevated lactate dehydrogenase (LDH) (p = 0.026), bone plasmacytomas (p = 0.001) and fractures (p = 0.002) at diagnosis, in patients with ExMeR compared to the others. ExMeR was associated with an ominous outcome, high LDH, constitutional symptoms and a statistically significant decrease of monoclonal paraprotein compared to levels at diagnosis (p = 0.009). Prior treatment with bortezomib was associated with a decreased hazard of ExMeR (p = 0.041). Overall survival (OS) was decreased in patients with ExMeR compared to the others (38 vs. 59 months, p = 0.006). Patients with MM with ExMeR have a lower OS and their clinical and laboratory features differ from those without.

  14. Using Interorganizational Partnerships to Strengthen Public Health Laboratory Systems

    PubMed Central

    Kimsey, Paul; Buehring, Gertrude

    2013-01-01

    Due to the current economic environment, many local and state health departments are faced with budget reductions. Health department administrators and public health laboratory (PHL) directors need to assess strategies to ensure that their PHLs can provide the same level of service with decreased funds. Exploratory case studies of interorganizational partnerships among local PHLs in California were conducted to determine the impact on local PHL testing services and capacity. Our findings suggest that interorganizational forms of cooperation among local PHLs can help bolster laboratory capacity by capturing economies of scale, leveraging scarce resources, and ensuring access to affordable, timely, and quality laboratory testing services. Interorganizational partnerships will help local and state public health departments continue to maintain a strong and robust laboratory system that supports their role in communicable disease surveillance. PMID:23997305

  15. The Workstation Approach to Laboratory Computing

    PubMed Central

    Crosby, P.A.; Malachowski, G.C.; Hall, B.R.; Stevens, V.; Gunn, B.J.; Hudson, S.; Schlosser, D.

    1985-01-01

    There is a need for a Laboratory Workstation which specifically addresses the problems associated with computing in the scientific laboratory. A workstation based on the IBM PC architecture and including a front end data acquisition system which communicates with a host computer via a high speed communications link; a new graphics display controller with hardware window management and window scrolling; and an integrated software package is described.

  16. Influence of study approaches and course design on academic success in the undergraduate anatomy laboratory.

    PubMed

    Eleazer, Courtney D; Scopa Kelso, Rebecca

    2018-01-04

    Many pre-health professional programs require completion of an undergraduate anatomy course with a laboratory component, yet grades in these courses are often low. Many students perceive anatomy as a more challenging subject than other coursework, and the resulting anxiety surrounding this perception may be a significant contributor to poor performance. Well-planned and deliberate guidance from instructors, as well as thoughtful course design, may be necessary to assist students in finding the best approach to studying for anatomy. This article assesses which study habits are associated with course success and whether course design influences study habits. Surveys (n = 1,274) were administered to students enrolled in three undergraduate human anatomy laboratory courses with varying levels of cooperative learning and structured guidance. The surveys collected information on potential predictors of performance, including student demographics, educational background, self-assessment ability, and study methods (e.g., flashcards, textbooks, diagrams). Compared to low performers, high performers perceive studying in laboratory, asking the instructor questions, quizzing alone, and quizzing others as more effective for learning. Additionally, students co-enrolled in a flipped, active lecture anatomy course achieve higher grades and find active learning activities (e.g., quizzing alone and in groups) more helpful for their learning in the laboratory. These results strengthen previous research suggesting that student performance is more greatly enhanced by an active classroom environment that practices successful study strategies rather than one that simply encourages students to employ such strategies inside and outside the classroom. Anat Sci Educ. © 2018 American Association of Anatomists. © 2018 American Association of Anatomists.

  17. Field metabolomics and laboratory assessments of anaerobic intrinsic bioremediation of hydrocarbons at a petroleum‐contaminated site

    PubMed Central

    Parisi, Victoria A.; Brubaker, Gaylen R.; Zenker, Matthew J.; Prince, Roger C.; Gieg, Lisa M.; Da Silva, Marcio L.B.; Alvarez, Pedro J. J.; Suflita, Joseph M.

    2009-01-01

    Summary Field metabolomics and laboratory assays were used to assess the in situ anaerobic attenuation of hydrocarbons in a contaminated aquifer underlying a former refinery. Benzene, ethylbenzene, 2‐methylnaphthalene, 1,2,4‐ and 1,3,5‐trimethylbenzene were targeted as contaminants of greatest regulatory concern (COC) whose intrinsic remediation has been previously reported. Metabolite profiles associated with anaerobic hydrocarbon decay revealed the microbial utilization of alkylbenzenes, including the trimethylbenzene COC, PAHs and several n‐alkanes in the contaminated portions of the aquifer. Anaerobic biodegradation experiments designed to mimic in situ conditions showed no loss of exogenously amended COC; however, a substantive rate of endogenous electron acceptor reduction was measured (55 ± 8 µM SO4 day−1). An assessment of hydrocarbon loss in laboratory experiments relative to a conserved internal marker revealed that non‐COC hydrocarbons were being metabolized. Purge and trap analysis of laboratory assays showed a substantial loss of toluene, m‐ and o‐xylene, as well as several alkanes (C6–C12). Multiple lines of evidence suggest that benzene is persistent under the prevailing site anaerobic conditions. We could find no in situ benzene intermediates (phenol or benzoate), the parent molecule proved recalcitrant in laboratory assays and low copy numbers of Desulfobacterium were found, a genus previously implicated in anaerobic benzene biodegradation. This study also showed that there was a reasonable correlation between field and laboratory findings, although with notable exception. Thus, while the intrinsic anaerobic bioremediation was clearly evident at the site, non‐COC hydrocarbons were preferentially metabolized, even though there was ample literature precedence for the biodegradation of the target molecules. PMID:21261914

  18. Das Sprachlabor in der Schule (The Language Laboratory in Schools).

    ERIC Educational Resources Information Center

    Cabus, Hans-Joachim; Freudenstein, Reinhold

    This technical manual for the use of language laboratories includes information on the following topics: (1) types of laboratories, (2) the tape, (3) the tape recorder, (4) other basic technical equipment, (5) the audio-active laboratory, the audio-active-compare laboratory, and an evaluation of the two, (6) possibilities for expanded use, (7)…

  19. Anatomic pathology laboratory information systems: a review.

    PubMed

    Park, Seung Lyung; Pantanowitz, Liron; Sharma, Gaurav; Parwani, Anil Vasdev

    2012-03-01

    The modern anatomic pathology laboratory depends on a reliable information infrastructure to register specimens, record gross and microscopic findings, regulate laboratory workflow, formulate and sign out report(s), disseminate them to the intended recipients across the whole health system, and support quality assurance measures. This infrastructure is provided by the Anatomical Pathology Laboratory Information Systems (APLIS), which have evolved over decades and now are beginning to support evolving technologies like asset tracking and digital imaging. As digital pathology transitions from "the way of the future" to "the way of the present," the APLIS continues to be one of the key effective enablers of the scope and practice of pathology. In this review, we discuss the evolution, necessary components, architecture and functionality of the APLIS that are crucial to today's practicing pathologist and address the demands of emerging trends on the future APLIS.

  20. Managing Science: Management for R&D Laboratories

    NASA Astrophysics Data System (ADS)

    Gelès, Claude; Lindecker, Gilles; Month, Mel; Roche, Christian

    1999-10-01

    A unique "how-to" manual for the management of scientific laboratories This book presents a complete set of tools for the management of research and development laboratories and projects. With an emphasis on knowledge rather than profit as a measure of output and performance, the authors apply standard management principles and techniques to the needs of high-flux, open-ended, separately funded science and technology enterprises. They also propose the novel idea that failure, and incipient failure, is an important measure of an organization's potential. From the management of complex, round-the-clock, high-tech operations to strategies for long-term planning, Managing Science: Management for R&D Laboratories discusses how to build projects with the proper research and development, obtain and account for funding, and deal with rapidly changing technologies, facilities, and trends. The entire second part of the book is devoted to personnel issues and the impact of workplace behavior on the various functions of a knowledge-based organization. Drawing on four decades of involvement with the management of scientific laboratories, the authors thoroughly illustrate their philosophy with real-world examples from the physics field and provide tables and charts. Managers of scientific laboratories as well as scientists and engineers expecting to move into management will find Managing Science: Management for R&D Laboratories an invaluable practical guide.

  1. Building capacity in laboratory medicine in Africa by increasing physician involvement: a laboratory medicine course for clinicians.

    PubMed

    Guarner, Jeannette; Amukele, Timothy; Mehari, Meheretu; Gemechu, Tufa; Woldeamanuel, Yimtubezinash; Winkler, Anne M; Asrat, Daniel; Wilson, Michael L; del Rio, Carlos

    2015-03-01

    To describe a 4-day laboratory medicine course for clinicians given at Addis Ababa University, Ethiopia, designed to improve the use of laboratory-based diagnoses. Each day was dedicated to one of the following topics: hematology, blood bank/transfusion medicine and coagulation, chemistry, and microbiology. The course included lectures, case-based learning, laboratory tours, and interactive computer case-based homework. The same 12-question knowledge quiz was given before and after the course. Twenty-eight participants took the quiz before and 21 after completing the course. The average score was 5.28 (range, 2-10) for the initial quiz and 8.09 (range, 4-11) for the second quiz (P = .0001). Two of 12 and 8 of 12 questions were answered correctly by more than 60% of trainees on the initial and second quiz, respectively. Knowledge and awareness of the role of the laboratory increased after participation in the course. Understanding of laboratory medicine principles by clinicians will likely improve use of laboratory services and build capacity in Africa. Copyright© by the American Society for Clinical Pathology.

  2. Growth and maintenance of Escherichia coli laboratory strains.

    PubMed

    Son, Mike S; Taylor, Ronald K

    2012-11-01

    Escherichia coli is a Gram-negative bacterium, commonly used in both teaching and research laboratories. This unit includes protocols for the growth and maintenance of E. coli in any teaching- or research-associated laboratory. © 2012 by John Wiley & Sons, Inc.

  3. Errors in laboratory medicine: practical lessons to improve patient safety.

    PubMed

    Howanitz, Peter J

    2005-10-01

    Patient safety is influenced by the frequency and seriousness of errors that occur in the health care system. Error rates in laboratory practices are collected routinely for a variety of performance measures in all clinical pathology laboratories in the United States, but a list of critical performance measures has not yet been recommended. The most extensive databases describing error rates in pathology were developed and are maintained by the College of American Pathologists (CAP). These databases include the CAP's Q-Probes and Q-Tracks programs, which provide information on error rates from more than 130 interlaboratory studies. To define critical performance measures in laboratory medicine, describe error rates of these measures, and provide suggestions to decrease these errors, thereby ultimately improving patient safety. A review of experiences from Q-Probes and Q-Tracks studies supplemented with other studies cited in the literature. Q-Probes studies are carried out as time-limited studies lasting 1 to 4 months and have been conducted since 1989. In contrast, Q-Tracks investigations are ongoing studies performed on a yearly basis and have been conducted only since 1998. Participants from institutions throughout the world simultaneously conducted these studies according to specified scientific designs. The CAP has collected and summarized data for participants about these performance measures, including the significance of errors, the magnitude of error rates, tactics for error reduction, and willingness to implement each of these performance measures. A list of recommended performance measures, the frequency of errors when these performance measures were studied, and suggestions to improve patient safety by reducing these errors. Error rates for preanalytic and postanalytic performance measures were higher than for analytic measures. Eight performance measures were identified, including customer satisfaction, test turnaround times, patient identification

  4. Roles of the International Council for Laboratory Animal Science (ICLAS) and International Association of Colleges of Laboratory Animal Medicine (IACLAM) in the Global Organization and Support of 3Rs Advances in Laboratory Animal Science.

    PubMed

    Turner, Patricia V; Pekow, Cynthia; Clark, Judy MacArthur; Vergara, Patri; Bayne, Kathryn; White, William J; Kurosawa, Tsutomu Miki; Seok, Seung-Hyeok; Baneux, Philippe

    2015-03-01

    Practical implementation of the 3Rs at national and regional levels around the world requires long-term commitment, backing, and coordinated efforts by international associations for laboratory animal medicine and science, including the International Association of Colleges of Laboratory Animal Medicine (IACLAM) and the International Council for Laboratory Animal Science (ICLAS). Together these organizations support the efforts of regional organization and communities of laboratory animal science professionals as well as the development of local associations and professional colleges that promote the training and continuing education of research facility personnel and veterinary specialists. The recent formation of a World Organization for Animal Health (OIE) Collaborating Center for Laboratory Animal Science and Welfare emphasizes the need for research into initiatives promoting laboratory animal welfare, particularly in emerging economies and regions with nascent associations of laboratory animal science.

  5. The laboratory workforce shortage: a managerial perspective.

    PubMed

    Cortelyou-Ward, Kendall; Ramirez, Bernardo; Rotarius, Timothy

    2011-01-01

    Most clinical laboratories in the nation report severe difficulties in recruitment and retention of most types of personnel. Other important factors impacting this problem include work complexities, increased automation, and a graying workforce. As a further challenge, institutional needs for clinical laboratory personnel are expected to grow significantly in the next decade. This article examines the current situation of the clinical laboratory workforce. It analyzes the different types of personnel; the managerial, supervision, and line positions that are key for different types of laboratories; the job outlook and recent projections for different types of staff; and the current issues, trends, and challenges of the laboratory workforce. Laboratory managers need to take action with strategies suggested for overcoming these challenges. Most importantly, they need to become transformational leaders by developing effective staffing models, fostering healthy and productive work environments, and creating value with a strategic management culture and implementation of knowledge management.

  6. Sequim Marine Research Laboratory routine environmental measurements during CY-1976

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fix, J.J.; Blumer, P.J.

    1977-05-01

    Beginning in 1976, a routine environmental program was established at the Marine Research Laboratory (MRL) at Sequim, Washington. The program is designed, primarily, to determine levels of radioactivity present in selected biota in Sequim Bay. The biota were selected because of their presence near the laboratory and their capacity to concentrate trace elements. Other samples were obtained to determine the radionuclides in Sequim Bay and laboratory drinking water, as well as the ambient radiation exposure levels and surface deposition of fallout radionuclides for the laboratory area. A summary of the analytical methods used is included. The present document includes datamore » obtained during CY 1976, the first year of the program. Radionuclides present in samples are attributed to fallout. Data are included on content of oil and Cu in seawater samples.« less

  7. The Tanzania experience: clinical laboratory testing harmonization and equipment standardization at different levels of a tiered health laboratory system.

    PubMed

    Massambu, Charles; Mwangi, Christina

    2009-06-01

    The rapid scale-up of the care and treatment programs in Tanzania during the preceding 4 years has greatly increased the demand for quality laboratory services for diagnosis of HIV and monitoring patients during antiretroviral therapy. Laboratory services were not in a position to cope with this demand owing to poor infrastructure, lack of human resources, erratic and/or lack of reagent supply and commodities, and slow manual technologies. With the limited human resources in the laboratory and the need for scaling up the care and treatment program, it became necessary to install automated equipment and train personnel for the increased volume of testing and new tests across all laboratory levels. With the numerous partners procuring equipment, the possibility of a multitude of equipment platforms with attendant challenges for procurement of reagents, maintenance of equipment, and quality assurance arose. Tanzania, therefore, had to harmonize laboratory tests and standardize laboratory equipment at different levels of the laboratory network. The process of harmonization of tests and standardization of equipment included assessment of laboratories, review of guidelines, development of a national laboratory operational plan, and stakeholder advocacy. This document outlines this process.

  8. The Johns Hopkins Hunterian Laboratory Philosophy: Mentoring Students in a Scientific Neurosurgical Research Laboratory.

    PubMed

    Tyler, Betty M; Liu, Ann; Sankey, Eric W; Mangraviti, Antonella; Barone, Michael A; Brem, Henry

    2016-06-01

    After over 50 years of scientific contribution under the leadership of Harvey Cushing and later Walter Dandy, the Johns Hopkins Hunterian Laboratory entered a period of dormancy between the 1960s and early 1980s. In 1984, Henry Brem reinstituted the Hunterian Neurosurgical Laboratory, with a new focus on localized delivery of therapies for brain tumors, leading to several discoveries such as new antiangiogenic agents and Gliadel chemotherapy wafers for the treatment of malignant gliomas. Since that time, it has been the training ground for 310 trainees who have dedicated their time to scientific exploration in the lab, resulting in numerous discoveries in the area of neurosurgical research. The Hunterian Neurosurgical Laboratory has been a unique example of successful mentoring in a translational research environment. The laboratory's philosophy emphasizes mentorship, independence, self-directed learning, creativity, and people-centered collaboration, while maintaining productivity with a focus on improving clinical outcomes. This focus has been served by the diverse backgrounds of its trainees, both in regard to educational status as well as culturally. Through this philosophy and strong legacy of scientific contribution, the Hunterian Laboratory has maintained a positive and productive research environment that supports highly motivated students and trainees. In this article, the authors discuss the laboratory's training philosophy, linked to the principles of adult learning (andragogy), as well as the successes and the limitations of including a wide educational range of students in a neurosurgical translational laboratory and the phenomenon of combining clinical expertise with rigorous scientific training.

  9. Heart rate variability indicates emotional value during pro-social economic laboratory decisions with large external validity.

    PubMed

    Fooken, Jonas

    2017-03-10

    The present study investigates the external validity of emotional value measured in economic laboratory experiments by using a physiological indicator of stress, heart rate variability (HRV). While there is ample evidence supporting the external validity of economic experiments, there is little evidence comparing the magnitude of internal levels of emotional stress during decision making with external stress. The current study addresses this gap by comparing the magnitudes of decision stress experienced in the laboratory with the stress from outside the laboratory. To quantify a large change in HRV, measures observed in the laboratory during decision-making are compared to the difference between HRV during a university exam and other mental activity for the same individuals in and outside of the laboratory. The results outside the laboratory inform about the relevance of laboratory findings in terms of their relative magnitude. Results show that psychologically induced HRV changes observed in the laboratory, particularly in connection with social preferences, correspond to large effects outside. This underscores the external validity of laboratory findings and shows the magnitude of emotional value connected to pro-social economic decisions in the laboratory.

  10. Clinical and Laboratory Characteristics of a Tinea Capitis Outbreak Among Novice Buddhist Monks.

    PubMed

    Bunyaratavej, Sumanas; Leeyaphan, Charussri; Rujitharanawong, Chuda; Muanprasat, Chanai; Matthapan, Lalita

    2017-05-01

    Sixty novice Buddhist monks with tinea capitis confirmed according to clinical presentation and mycological laboratory finding were included in this study. Mixed-type clinical presentation was observed in approximately half of all cases, together with scarring alopecia (95%) and superficial fungal skin infection at locations other than the scalp (43.3%). The major isolated organism was Trichophyton violaceum, and mixed-organism infection was found in 27 cases (45%). Slow-onset presentation and an extensive area of infection were significantly associated with mixed-type clinical presentation. © 2017 Wiley Periodicals, Inc.

  11. Geometry Laboratory (GEOLAB) surface modeling and grid generation technology and services

    NASA Technical Reports Server (NTRS)

    Kerr, Patricia A.; Smith, Robert E.; Posenau, Mary-Anne K.

    1995-01-01

    The facilities and services of the GEOmetry LABoratory (GEOLAB) at the NASA Langley Research Center are described. Included in this description are the laboratory functions, the surface modeling and grid generation technologies used in the laboratory, and examples of the tasks performed in the laboratory.

  12. A Virtual Embedded Microcontroller Laboratory for Undergraduate Education: Development and Evaluation

    ERIC Educational Resources Information Center

    Richardson, Jeffrey J.; Adamo-Villani, Nicoletta

    2010-01-01

    Laboratory instruction is a major component of the engineering and technology undergraduate curricula. Traditional laboratory instruction is hampered by several factors including limited access to resources by students and high laboratory maintenance cost. A photorealistic 3D computer-simulated laboratory for undergraduate instruction in…

  13. Environmental Response Laboratory Network Membership and Benefits

    EPA Pesticide Factsheets

    Member laboratories must meet core requirements including quality systems, policies and procedures, sample and data management, and analytical capabilities. Benefits include training and exercise opportunities, information sharing and technical support.

  14. Pacific Northwest National Laboratory institutional plan: FY 1996--2001

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-01-01

    This report contains the operation and direction plan for the Pacific Northwest National Laboratory of the US Department of Energy. The topics of the plan include the laboratory mission and core competencies, the laboratory strategic plan; the laboratory initiatives in molecular sciences, microbial biotechnology, global environmental change, complex modeling of physical systems, advanced processing technology, energy technology development, and medical technologies and systems; core business areas, critical success factors, and resource projections.

  15. Laboratory findings in neurosyphilis patients with epileptic seizures alone as the initial presenting symptom.

    PubMed

    Tong, Man-Li; Liu, Li-Li; Zeng, Yan-Li; Zhang, Hui-Lin; Liu, Gui-Li; Zheng, Wei-Hong; Dong, Jie; Wu, Jing-Yi; Su, Yuan-Hui; Lin, Li-Rong; Yang, Tian-Ci

    2013-04-01

    A retrospective chart review was performed to characterize the clinical presentation, the characteristic combination of serologic and cerebrospinal fluid (CSF) abnormalities, and the neuroimaging findings of neurosyphilis (NS) patients who had epileptic seizures alone as an initial presenting symptom. In a 6.75-year period, 169 inpatients with NS were identified at Zhongshan Hospital (from June 2005 to February 2012). We demonstrated that 13 (7.7%) of the 169 NS patients had epileptic seizures alone as an initial presenting feature. Epileptic seizures occurred in NS patients with syphilitic meningitis (2 cases), meningovascular NS (5 cases), and general paresis (6 cases). The types of epileptic seizures included simple partial, complex partial with secondary generalization (including status epilepticus), and generalized seizures (no focal onset reported). Nine of NS patients with only epileptic seizures as primary symptom were misdiagnosed, and the original misdiagnosis was 69.23% (9/13). Ten (10/13, 76.9%) patients had an abnormal magnetic resonance imaging, and 7 (7/13 53.8%) patients had abnormal electroencephalogram recordings. In addition, the sera rapid plasma reagin (RPR) and Treponema pallidum particle agglutination (TPPA) from all 13 patients were positive. The overall positive rates of the CSF-RPR and CSF-TPPA were 61.5% and 69.2%, respectively. Three patients demonstrated CSF pleocytosis, and 9 patients exhibited elevated CSF protein levels. Therefore, NS with only epileptic seizures at the initial presentation exhibits a lack of specificity. It is recommended that every patient with clinically evident symptoms of epileptic seizures should have a blood test performed for syphilis. When the serology results are positive, all of the patients should undergo a CSF examination to diagnose NS. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. A comparison of traditional physical laboratory and computer-simulated laboratory experiences in relation to engineering undergraduate students' conceptual understandings of a communication systems topic

    NASA Astrophysics Data System (ADS)

    Javidi, Giti

    2005-07-01

    This study was designed to investigate an alternative to the use of traditional physical laboratory activities in a communication systems course. Specifically, this study examined whether as an alternative, computer simulation is as effective as physical laboratory activities in teaching college-level electronics engineering education students about the concepts of signal transmission, modulation and demodulation. Eighty undergraduate engineering students participated in the study, which was conducted at a southeastern four-year university. The students were randomly assigned to two groups. The groups were compared on understanding the concepts, remembering the concepts, completion time of the lab experiments and perception toward the laboratory experiments. The physical group's (n = 40) treatment was to conduct laboratory experiments in a physical laboratory. The students in this group used equipment in a controlled electronics laboratory. The Simulation group's (n = 40) treatment was to conduct similar experiments in a PC laboratory. The students in this group used a simulation program in a controlled PC lab. At the completion of the treatment, scores on a validated conceptual test were collected once after the treatment and again three weeks after the treatment. Attitude surveys and qualitative study were administered at the completion of the treatment. The findings revealed significant differences, in favor of the simulation group, between the two groups on both the conceptual post-test and the follow-up test. The findings also revealed significant correlation between simulation groups' attitude toward the simulation program and their post-test scores. Moreover, there was a significant difference between the two groups on their attitude toward their laboratory experience in favor of the simulation group. In addition, there was significant difference between the two groups on their lab completion time in favor of the simulation group. At the same time, the

  17. National and international veterinary reference laboratories for infectious diseases.

    PubMed

    Edwards, S; Alexander, D

    1998-08-01

    Reference laboratories play an increasingly important role in the harmonisation of laboratory diagnostic tests and the standardisation of veterinary vaccines. This is particularly important in building confidence between international trading partners. The authors review aspects of the organisation, designation and support of reference laboratories for infectious diseases of animals and discuss the principal activities which such laboratories would normally perform. These activities include advice and consultancy, publications and communication, training, research, disease surveillance, maintenance of culture collections, evaluation of reference methods, preparation of reference materials and organisation of inter-laboratory comparisons.

  18. Six Strategies for Chemical Waste Minimization in Laboratories.

    ERIC Educational Resources Information Center

    Matteson, Gary C.; Hadley, Cheri R.

    1991-01-01

    Guidelines are offered to research administrators for reducing the volume of hazardous laboratory waste. Suggestions include a chemical location inventory, a chemical reuse facility, progressive contracts with chemical suppliers, internal or external chemical recycling mechanisms, a "chemical conservation" campaign, and laboratory fees for…

  19. Laboratory diagnosis of von Willebrand's disease.

    PubMed

    Rick, M E

    1994-12-01

    The diagnosis of von Willebrand's disease is becoming complex as more is understood about the disease. Clinical information and laboratory data are necessary for the diagnosis because of the overlap of normal and abnormal laboratory values. A complete evaluation including von Willebrand factor multimers, ristocetin-induced platelet aggregation, factor VIII activity level, and a template bleeding time is necessary to correctly classify the patient so that optimal treatment may be given.

  20. Analysis of on-line clinical laboratory manuals and practical recommendations.

    PubMed

    Beckwith, Bruce; Schwartz, Robert; Pantanowitz, Liron

    2004-04-01

    On-line clinical laboratory manuals are a valuable resource for medical professionals. To our knowledge, no recommendations currently exist for their content or design. To analyze publicly accessible on-line clinical laboratory manuals and to propose guidelines for their content. We conducted an Internet search for clinical laboratory manuals written in English with individual test listings. Four individual test listings in each manual were evaluated for 16 data elements, including sample requirements, test methodology, units of measure, reference range, and critical values. Web sites were also evaluated for supplementary information and search functions. We identified 48 on-line laboratory manuals, including 24 academic or community hospital laboratories and 24 commercial or reference laboratories. All manuals had search engines and/or test indices. No single manual contained all 16 data elements evaluated. An average of 8.9 (56%) elements were present (range, 4-14). Basic sample requirements (specimen and volume needed) were the elements most commonly present (98% of manuals). The frequency of the remaining data elements varied from 10% to 90%. On-line clinical laboratory manuals originate from both hospital and commercial laboratories. While most manuals were user-friendly and contained adequate specimen-collection information, other important elements, such as reference ranges, were frequently absent. To ensure that clinical laboratory manuals are of maximal utility, we propose the following 13 data elements be included in individual test listings: test name, synonyms, test description, test methodology, sample requirements, volume requirements, collection guidelines, transport guidelines, units of measure, reference range, critical values, test availability, and date of latest revision.

  1. Implications of the introduction of laboratory demand management at primary care clinics in South Africa on laboratory expenditure

    PubMed Central

    Lekalakala, Ruth; Asmall, Shaidah; Cassim, Naseem

    2016-01-01

    Background Diagnostic health laboratory services are regarded as an integral part of the national health infrastructure across all countries. Clinical laboratory tests contribute substantially to health system goals of increasing quality of care and improving patient outcomes. Objectives This study aimed to analyse current laboratory expenditures at the primary healthcare (PHC) level in South Africa as processed by the National Health Laboratory Service and to determine the potential cost savings of introducing laboratory demand management. Methods A retrospective cross-sectional analysis of laboratory expenditures for the 2013/2014 financial year across 11 pilot National Health Insurance health districts was conducted. Laboratory expenditure tariff codes were cross-tabulated to the PHC essential laboratory tests list (ELL) to determine inappropriate testing. Data were analysed using a Microsoft Access database and Excel software. Results Approximately R35 million South African Rand (10%) of the estimated R339 million in expenditures was for tests that were not listed within the ELL. Approximately 47% of expenditure was for laboratory tests that were indicated in the algorithmic management of patients on antiretroviral treatment. The other main cost drivers for non-ELL testing included full blood count and urea, as well as electrolyte profiles usually requested to support management of patients on antiretroviral treatment. Conclusions Considerable annual savings of up to 10% in laboratory expenditure are possible at the PHC level by implementing laboratory demand management. In addition, to achieve these savings, a standardised PHC laboratory request form and some form of electronic gatekeeping system that must be supported by an educational component should be implemented. PMID:28879107

  2. Laboratory Validation and Field Assessment of Petroleum Laboratory Technicians' Dermal Exposure to Crude Oil Using a Wipe Sampling Method.

    PubMed

    Galea, Karen S; Mueller, Will; Arfaj, Ayman M; Llamas, Jose L; Buick, Jennifer; Todd, David; McGonagle, Carolyn

    2018-05-21

    Crude oil may cause adverse dermal effects therefore dermal exposure is an exposure route of concern. Galea et al. (2014b) reported on a study comparing recovery (wipe) and interception (cotton glove) dermal sampling methods. The authors concluded that both methods were suitable for assessing dermal exposure to oil-based drilling fluids and crude oil but that glove samplers may overestimate the amount of fluid transferred to the skin. We describe a study which aimed to further evaluate the wipe sampling method to assess dermal exposure to crude oil, with this assessment including extended sample storage periods and sampling efficiency tests being undertaken at environmental conditions to mimic those typical of outdoor conditions in Saudi Arabia. The wipe sampling method was then used to assess the laboratory technicians' actual exposure to crude oil during typical petroleum laboratory tasks. Overall, acceptable storage efficiencies up to 54 days were reported with results suggesting storage stability over time. Sampling efficiencies were also reported to be satisfactory at both ambient and elevated temperature and relative humidity environmental conditions for surrogate skin spiked with known masses of crude oil and left up to 4 h prior to wiping, though there was an indication of reduced sampling efficiency over time. Nineteen petroleum laboratory technicians provided a total of 35 pre- and 35 post-activity paired hand wipe samples. Ninety-three percent of the pre-exposure paired hand wipes were less than the analytical limit of detection (LOD), whereas 46% of the post-activity paired hand wipes were less than the LOD. The geometric mean paired post-activity wipe sample measurement was 3.09 µg cm-2 (range 1.76-35.4 µg cm-2). It was considered that dermal exposure most frequently occurred through direct contact with the crude oil (emission) or via deposition. The findings of this study suggest that the wipe sampling method is satisfactory in quantifying

  3. Teaching pediatric laboratory medicine to pathology residents.

    PubMed

    Pysher, Theodore J; Bach, Philip R; Geaghan, Sharon M; Hamilton, Marilyn S; Laposata, Michael; Lockitch, Gillian; Brugnara, Carlo; Coffin, Cheryl M; Pasquali, Marzia; Rinaldo, Piero; Roberts, William L; Rutledge, Joe C; Ashwood, Edward R; Blaylock, Robert C; Campos, Joseph M; Goldsmith, Barbara; Jones, Patricia M; Lim, Megan; Meikle, A Wayne; Perkins, Sherrie L; Perry, Deborah A; Petti, Cathy A; Rogers, Beverly B; Steele, Paul E; Weiss, Ronald L; Woods, Gail

    2006-07-01

    Laboratory data are essential to the medical care of fetuses, infants, children, and adolescents. However, the performance and interpretation of laboratory tests on specimens from these patients, which may constitute a significant component of the workload in general hospitals and integrated health care systems as well as specialized perinatal or pediatric centers, present unique challenges to the clinical pathologist and the laboratory. Therefore, pathology residents should receive training in pediatric laboratory medicine. Children's Health Improvement through Laboratory Diagnostics, a group of pathologists and laboratory scientists with interest and expertise in pediatric laboratory medicine, convened a task force to develop a list of curriculum topics, key resources, and training experiences in pediatric laboratory medicine for trainees in anatomic and clinical pathology or straight clinical pathology residency programs and in pediatric pathology fellowship programs. Based on the experiences of 11 training programs, we have compiled a comprehensive list of pediatric topics in the areas of clinical chemistry, endocrinology, hematology, urinalysis, coagulation medicine, transfusion medicine, immunology, microbiology and virology, biochemical genetics, cytogenetics and molecular diagnostics, point of care testing, and laboratory management. This report also includes recommendations for training experiences and a list of key texts and other resources in pediatric laboratory medicine. Clinical pathologists should be trained to meet the laboratory medicine needs of pediatric patients and to assist the clinicians caring for these patients with the selection and interpretation of laboratory studies. This review helps program directors tailor their curricula to more effectively provide this training.

  4. INNOVATIONS IN EQUIPMENT AND TECHNIQUES FOR THE BIOLOGY TEACHING LABORATORY.

    ERIC Educational Resources Information Center

    BARTHELEMY, RICHARD E.; AND OTHERS

    LABORATORY TECHNIQUES AND EQUIPMENT APPROPRIATE FOR TEACHING BIOLOGICAL SCIENCE CURRICULUM STUDY BIOLOGY ARE EMPHASIZED. MAJOR CATEGORIES INCLUDE (1) LABORATORY FACILITIES, (2) EQUIPMENT AND TECHNIQUES FOR CULTURE OF MICRO-ORGANISMS, (3) LABORATORY ANIMALS AND THEIR HOUSING, (4) TECHNIQUES FOR STUDYING PLANT GROWTH, (5) TECHNIQUES FOR STUDYING…

  5. Laboratory maintenance of Treponema denticola.

    PubMed

    Fenno, J Christopher

    2005-10-01

    This unit describes the methods, media, and equipment necessary for routine laboratory culture and handling of the anaerobic oral spirochete Treponema denticola. Topics discussed include nutrient requirements, recommended media formulations, and expected growth kinetics, as well as methods and equipment necessary to maintain anaerobic conditions. An additional protocol on isolation of T. denticola from clinical samples is included.

  6. Students' framing of laboratory exercises using infrared cameras

    NASA Astrophysics Data System (ADS)

    Haglund, Jesper; Jeppsson, Fredrik; Hedberg, David; Schönborn, Konrad J.

    2015-12-01

    Thermal science is challenging for students due to its largely imperceptible nature. Handheld infrared cameras offer a pedagogical opportunity for students to see otherwise invisible thermal phenomena. In the present study, a class of upper secondary technology students (N =30 ) partook in four IR-camera laboratory activities, designed around the predict-observe-explain approach of White and Gunstone. The activities involved central thermal concepts that focused on heat conduction and dissipative processes such as friction and collisions. Students' interactions within each activity were videotaped and the analysis focuses on how a purposefully selected group of three students engaged with the exercises. As the basis for an interpretative study, a "thick" narrative description of the students' epistemological and conceptual framing of the exercises and how they took advantage of the disciplinary affordance of IR cameras in the thermal domain is provided. Findings include that the students largely shared their conceptual framing of the four activities, but differed among themselves in their epistemological framing, for instance, in how far they found it relevant to digress from the laboratory instructions when inquiring into thermal phenomena. In conclusion, the study unveils the disciplinary affordances of infrared cameras, in the sense of their use in providing access to knowledge about macroscopic thermal science.

  7. The chemistry teaching laboratory: The student perspective

    NASA Astrophysics Data System (ADS)

    Polles, John Steven

    In this study, I investigated the Student/learner's experiences in the chemistry teaching laboratory and the meaning that she or he derived from these experiences. This study sought to answer these questions: (1) What was the students experience in the teaching laboratory?, (2) What aspects of the laboratory experience did the student value?, and (3) What beliefs did the student hold concerning the role of the laboratory experience in developing her or his understanding of chemistry? Students involved in an introductory chemistry course at Purdue University were asked to complete a two-part questionnaire consisting of 16 scaled response and 5 free response items, and 685 did so. Fourteen students also participated in a semi-structured individual interview. The questionnaire and interview were designed to probe the students' perceived experience and answer the above questions. I found that students possess strong conceptions of the laboratory experience: a pre-conception that colors their experience from the outset, and a post-conception that is a mix of positive and negative reflections. I also found that the learner deeply holds an implicit value in the laboratory experience. The other major finding was that the students' lived experience is dramatically shaped or influenced by external agencies, primarily the faculty (and by extension the teaching assistants). There is much debate in the extant literature over the learning value of the science teaching laboratory, but it is all from the perspective of faculty, curriculum designers, and administrators. This study adds the students' voice to the argument.

  8. Roles of the International Council for Laboratory Animal Science (ICLAS) and International Association of Colleges of Laboratory Animal Medicine (IACLAM) in the Global Organization and Support of 3Rs Advances in Laboratory Animal Science

    PubMed Central

    Turner, Patricia V; Pekow, Cynthia; Clark, Judy MacArthur; Vergara, Patri; Bayne, Kathryn; White, William J; Kurosawa, Tsutomu Miki; Seok, Seung-Hyeok; Baneux, Philippe

    2015-01-01

    Practical implementation of the 3Rs at national and regional levels around the world requires long-term commitment, backing, and coordinated efforts by international associations for laboratory animal medicine and science, including the International Association of Colleges of Laboratory Animal Medicine (IACLAM) and the International Council for Laboratory Animal Science (ICLAS). Together these organizations support the efforts of regional organization and communities of laboratory animal science professionals as well as the development of local associations and professional colleges that promote the training and continuing education of research facility personnel and veterinary specialists. The recent formation of a World Organization for Animal Health (OIE) Collaborating Center for Laboratory Animal Science and Welfare emphasizes the need for research into initiatives promoting laboratory animal welfare, particularly in emerging economies and regions with nascent associations of laboratory animal science. PMID:25836964

  9. Quality in laboratory medicine: 50years on.

    PubMed

    Plebani, Mario

    2017-02-01

    The last 50years have seen substantial changes in the landscape of laboratory medicine: its role in modern medicine is in evolution and the quality of laboratory services is changing. The need to control and improve quality in clinical laboratories has grown hand in hand with the growth in technological developments leading to an impressive reduction of analytical errors over time. An essential cause of this impressive improvement has been the introduction and monitoring of quality indicators (QIs) such as the analytical performance specifications (in particular bias and imprecision) based on well-established goals. The evolving landscape of quality and errors in clinical laboratories moved first from analytical errors to all errors performed within the laboratory walls, subsequently to errors in laboratory medicine (including errors in test requesting and result interpretation), and finally, to a focus on errors more frequently associated with adverse events (laboratory-associated errors). After decades in which clinical laboratories have focused on monitoring and improving internal indicators of analytical quality, efficiency and productivity, it is time to shift toward indicators of total quality, clinical effectiveness and patient outcomes. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  10. 42 CFR 493.1445 - Standard; Laboratory director responsibilities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... quality laboratory services for all aspects of test performance, which includes the preanalytic, analytic... result is found to be unacceptable or unsatisfactory; (5) Ensure that the quality control and quality assessment programs are established and maintained to assure the quality of laboratory services provided and...

  11. Mars Science Laboratory Spacecraft Assembled for Testing

    NASA Technical Reports Server (NTRS)

    2008-01-01

    The major components of NASA's Mars Science Laboratory spacecraft cruise stage atop the aeroshell, which has the descent stage and rover inside were connected together in October 2008 for several weeks of system testing, including simulation of launch vibrations and deep-space environmental conditions.

    These components will be taken apart again, for further work on each of them, after the environmental testing. The Mars Science Laboratory spacecraft is being assembled and tested for launch in 2011.

    This image was taken inside the Spacecraft Assembly Facility at NASA's Jet Propulsion Laboratory, Pasadena, Calif., which manages the Mars Science Laboratory Project for the NASA Science Mission Directorate, Washington. JPL is a division of the California Institute of Technology.

  12. A Consistent System for Coding Laboratory Samples

    NASA Astrophysics Data System (ADS)

    Sih, John C.

    1996-07-01

    A formal laboratory coding system is presented to keep track of laboratory samples. Preliminary useful information regarding the sample (origin and history) is gained without consulting a research notebook. Since this system uses and retains the same research notebook page number for each new experiment (reaction), finding and distinguishing products (samples) of the same or different reactions becomes an easy task. Using this system multiple products generated from a single reaction can be identified and classified in a uniform fashion. Samples can be stored and filed according to stage and degree of purification, e.g. crude reaction mixtures, recrystallized samples, chromatographed or distilled products.

  13. Updating the immunology curriculum in clinical laboratory science.

    PubMed

    Stevens, C D

    2000-01-01

    To determine essential content areas of immunology/serology courses at the clinical laboratory technician (CLT) and clinical laboratory scientist (CLS) levels. A questionnaire was designed which listed all major topics in immunology and serology. Participants were asked to place a check beside each topic covered. For an additional list of serological and immunological laboratory testing, participants were asked to indicate if each test was performed in either the didactic or clinical setting, or not performed at all. A national survey of 593 NAACLS approved CLT and CLS programs was conducted by mail under the auspices of ASCLS. Responses were obtained from 158 programs. Respondents from all across the United States included 60 CLT programs, 48 hospital-based CLS programs, 45 university-based CLS programs, and 5 university-based combined CLT and CLS programs. The survey was designed to enumerate major topics included in immunology and serology courses by a majority of participants at two distinct educational levels, CLT and CLS. Laboratory testing routinely performed in student laboratories as well as in the clinical setting was also determined for these two levels of practitioners. Certain key topics were common to most immunology and serology courses. There were some notable differences in the depth of courses at the CLT and CLS levels. Laboratory testing associated with these courses also differed at the two levels. Testing requiring more detailed interpretation, such as antinuclear antibody patterns (ANAs), was mainly performed by CLS students only. There are certain key topics as well as specific laboratory tests that should be included in immunology/serology courses at each of the two different educational levels to best prepare students for the workplace. Educators can use this information as a guide to plan a curriculum for such courses.

  14. Promoting Rapid Learning in the Histology Laboratory by Integrating Technology

    ERIC Educational Resources Information Center

    Shields, Vonnie

    2008-01-01

    This paper describes the results of incorporating technology in the histology laboratory by using high-resolution video-imaging equipment (VIE). The study sought to determine if (1) the VIE would allow students to more easily and rapidly find histological structures over more conventional methods, and (2) if they could find the structures with the…

  15. Effect of clinical and laboratory parameters on quality of life in celiac patients using celiac disease-specific quality of life scores.

    PubMed

    Lee, Jungmin; Clarke, Kofi

    2017-11-01

    Health-related quality of life (HR-QOL) in patients with celiac disease is reduced compared to the general population. We investigated the association between HR-QOL and clinical, laboratory findings using the previously validated CD-QOL (celiac disease-specific quality of life) instrument in patients with celiac disease. To our knowledge, no study has previously explored the relationship between HR-QOL and clinical, laboratory parameters in celiac patients. Patients who received care at the Allegheny Health Network Celiac Center, Pittsburgh, PA were asked to complete the CD-QOL questionnaire. A cross sectional study with predetermined clinical and laboratory parameters was performed. Data collected included IgA anti-tissue transglutaminase (tTG) antibody titers, iron studies, calcium, vitamin A, B12, 25 OH vitamin D, and E levels. Correlation between clinical findings and CD-QOL was also assessed. Seventy-eight out of 124 patients who completed the questionnaire was included in the analysis. Patients with concomitant irritable bowel syndrome (IBS) had significantly reduced HR-QOL with CD-QOL score of 52.4 ± 11.3 vs. 44.6 ± 12.9 in those without IBS (p = .009). There was no difference in HR-QOL in relation to IgA tTG titers or vitamin D levels. Of note, there was a trend towards correlation between higher level of vitamin E and better QOL (r = -0.236, p = .074). Celiac patients with concomitant IBS have reduced HR-QOL. There was no statistically significant association between HR-QOL and laboratory parameters or levels of micronutrients.

  16. Design and development of a solar powered mobile laboratory

    NASA Astrophysics Data System (ADS)

    Jiao, L.; Simon, A.; Barrera, H.; Acharya, V.; Repke, W.

    2016-08-01

    This paper describes the design and development of a solar powered mobile laboratory (SPML) system. The SPML provides a mobile platform that schools, universities, and communities can use to give students and staff access to laboratory environments where dedicated laboratories are not available. The lab includes equipment like 3D printers, computers, and soldering stations. The primary power source of the system is solar PV which allows the laboratory to be operated in places where the grid power is not readily available or not sufficient to power all the equipment. The main system components include PV panels, junction box, battery, charge controller, and inverter. Not only is it used to teach students and staff how to use the lab equipment, but it is also a great tool to educate the public about solar PV technologies.

  17. Laboratory identification of arthropod ectoparasites.

    PubMed

    Mathison, Blaine A; Pritt, Bobbi S

    2014-01-01

    The collection, handling, identification, and reporting of ectoparasitic arthropods in clinical and reference diagnostic laboratories are discussed in this review. Included are data on ticks, mites, lice, fleas, myiasis-causing flies, and bed bugs. The public health importance of these organisms is briefly discussed. The focus is on the morphological identification and proper handling and reporting of cases involving arthropod ectoparasites, particularly those encountered in the United States. Other arthropods and other organisms not of public health concern, but routinely submitted to laboratories for identification, are also briefly discussed.

  18. Laboratory Identification of Arthropod Ectoparasites

    PubMed Central

    Pritt, Bobbi S.

    2014-01-01

    SUMMARY The collection, handling, identification, and reporting of ectoparasitic arthropods in clinical and reference diagnostic laboratories are discussed in this review. Included are data on ticks, mites, lice, fleas, myiasis-causing flies, and bed bugs. The public health importance of these organisms is briefly discussed. The focus is on the morphological identification and proper handling and reporting of cases involving arthropod ectoparasites, particularly those encountered in the United States. Other arthropods and other organisms not of public health concern, but routinely submitted to laboratories for identification, are also briefly discussed. PMID:24396136

  19. Bootstrapping Methods Applied for Simulating Laboratory Works

    ERIC Educational Resources Information Center

    Prodan, Augustin; Campean, Remus

    2005-01-01

    Purpose: The aim of this work is to implement bootstrapping methods into software tools, based on Java. Design/methodology/approach: This paper presents a category of software e-tools aimed at simulating laboratory works and experiments. Findings: Both students and teaching staff use traditional statistical methods to infer the truth from sample…

  20. Current and Projected Modes of Delivery of Veterinary Medical Services to Animal Agriculture: Diagnostic Laboratory Services.

    ERIC Educational Resources Information Center

    Seaton, Vaughn A.

    1980-01-01

    The veterinary diagnostic laboratory's prime role has been diagnosis and/or laboratory findings to assist a diagnosis. Interpretation and evaluation and more involvement with decision-making in monitoring groups of animals and their health status are seen as future roles for diagnostic laboratories. (MLW)

  1. Components of laboratory accreditation.

    PubMed

    Royal, P D

    1995-12-01

    Accreditation or certification is a recognition given to an operation or product that has been evaluated against a standard; be it regulatory or voluntary. The purpose of accreditation is to provide the consumer with a level of confidence in the quality of operation (process) and the product of an organization. Environmental Protection Agency/OCM has proposed the development of an accreditation program under National Environmental Laboratory Accreditation Program for Good Laboratory Practice (GLP) laboratories as a supplement to the current program. This proposal was the result of the Inspector General Office reports that identified weaknesses in the current operation. Several accreditation programs can be evaluated and common components identified when proposing a structure for accrediting a GLP system. An understanding of these components is useful in building that structure. Internationally accepted accreditation programs provide a template for building a U.S. GLP accreditation program. This presentation will discuss the traditional structure of accreditation as presented in the Organization of Economic Cooperative Development/GLP program, ISO-9000 Accreditation and ISO/IEC Guide 25 Standard, and the Canadian Association for Environmental Analytical Laboratories, which has a biological component. Most accreditation programs are managed by a recognized third party, either privately or with government oversight. Common components often include a formal review of required credentials to evaluate organizational structure, a site visit to evaluate the facility, and a performance evaluation to assess technical competence. Laboratory performance is measured against written standards and scored. A formal report is then sent to the laboratory indicating accreditation status. Usually, there is a scheduled reevaluation built into the program. Fee structures vary considerably and will need to be examined closely when building a GLP program.

  2. Workgroup for Hydraulic laboratory Testing and Verification of Hydroacoustic Instrumentation

    USGS Publications Warehouse

    Fulford, Janice M.; Armstrong, Brandy N.; Thibodeaux, Kirk G.

    2015-01-01

    An international workgroup was recently formed for hydraulic laboratory testing and verification of hydroacoustic instrumentation used for water velocity measurements. The activities of the workgroup have included one face to face meeting, conference calls and an inter-laboratory exchange of two acoustic meters among participating laboratories. Good agreement was found among four laboratories at higher tow speeds and poorer agreement at the lowest tow speed.

  3. Assessing the outcome of Strengthening Laboratory Management Towards Accreditation (SLMTA) on laboratory quality management system in city government of Addis Ababa, Ethiopia

    PubMed Central

    Sisay, Abay; Mindaye, Tedla; Tesfaye, Abrham; Abera, Eyob; Desale, Adino

    2015-01-01

    Introduction Strengthening Laboratory Management Toward Accreditation (SLMTA) is a competency-based management training programme designed to bring about immediate and measurable laboratory improvement. The aim of this study is to assess the outcome of SLMTA on laboratory quality management system in Addis Ababa, Ethiopia. Methods The study used an Institutional based cross sectional study design that employed a secondary and primary data collection approach on the participated institution of medical laboratory in SLMTA. The study was conducted in Addis Ababa city government and the data was collected from February ‘April 2014 and data was entered in to EPI-data version 3.1 and was analyzed by SPSS version 20. Results The assessment finding indicate that there was a significant improvement in average scores (141.4; range of 65-196, 95%CI =86.275-115.5, p = 0.000) at final with 3 laboratories become 3 star, 6 laboratories were at 2 star, 11 were 1 star. Laboratory facilities respondents which thought getting adequate and timely manner mentorship were found 2.5 times more likely to get good success in the final score(AOR= 2.501, 95% CI= 1.109-4.602) than which did not get it. Conclusion At the end of SLMTA implementation,3 laboratories score 3 star, 6 laboratories were at 2 star, 11 were at 1 star. The most important contributing factor for not scoring star in the final outcome of SLMTA were not conducting their customer satisfaction survey, poor staff motivation, and lack of regular equipment service maintenance. Mentorship, onsite and offsite coaching and training activities had shown a great improvement on laboratory quality management system in most laboratories. PMID:26175805

  4. Assessing the outcome of Strengthening Laboratory Management Towards Accreditation (SLMTA) on laboratory quality management system in city government of Addis Ababa, Ethiopia.

    PubMed

    Sisay, Abay; Mindaye, Tedla; Tesfaye, Abrham; Abera, Eyob; Desale, Adino

    2015-01-01

    Strengthening Laboratory Management Toward Accreditation (SLMTA) is a competency-based management training programme designed to bring about immediate and measurable laboratory improvement. The aim of this study is to assess the outcome of SLMTA on laboratory quality management system in Addis Ababa, Ethiopia. The study used an Institutional based cross sectional study design that employed a secondary and primary data collection approach on the participated institution of medical laboratory in SLMTA. The study was conducted in Addis Ababa city government and the data was collected from February 'April 2014 and data was entered in to EPI-data version 3.1 and was analyzed by SPSS version 20. The assessment finding indicate that there was a significant improvement in average scores (141.4; range of 65-196, 95%CI=86.275-115.5, p=0.000) at final with 3 laboratories become 3 star, 6 laboratories were at 2 star, 11 were 1 star. Laboratory facilities respondents which thought getting adequate and timely manner mentorship were found 2.5 times more likely to get good success in the final score(AOR=2.501, 95% CI=1.109-4.602) than which did not get it. At the end of SLMTA implementation,3 laboratories score 3 star, 6 laboratories were at 2 star, 11 were at 1 star. The most important contributing factor for not scoring star in the final outcome of SLMTA were not conducting their customer satisfaction survey, poor staff motivation, and lack of regular equipment service maintenance. Mentorship, onsite and offsite coaching and training activities had shown a great improvement on laboratory quality management system in most laboratories.

  5. Introductory Industrial Technology I. Laboratory Activities.

    ERIC Educational Resources Information Center

    Towler, Alan L.; And Others

    This guide contains 36 learning modules intended for use by technology teachers and students in grades 7 and 8. Each module includes a student laboratory activity and instructor's resource sheet. Each student activity includes the following: activity topic and overview, challenge statement, objectives, vocabulary/concepts reinforced,…

  6. Introductory Industrial Technology II. Laboratory Activities.

    ERIC Educational Resources Information Center

    Towler, Alan L.

    This guide contains 29 learning modules intended for use by technology teachers and students in grade 8. Each module includes a student laboratory activity and instructor's resource sheet. Each student activity includes the following: activity topic and overview, challenge statement, objectives, vocabulary/concepts reinforced, equipment/supplies,…

  7. Transferability and within- and between-laboratory reproducibilities of EpiSensA for predicting skin sensitization potential in vitro: A ring study in three laboratories.

    PubMed

    Mizumachi, Hideyuki; Sakuma, Megumi; Ikezumi, Mayu; Saito, Kazutoshi; Takeyoshi, Midori; Imai, Noriyasu; Okutomi, Hiroko; Umetsu, Asami; Motohashi, Hiroko; Watanabe, Mika; Miyazawa, Masaaki

    2018-05-03

    The epidermal sensitization assay (EpiSensA) is an in vitro skin sensitization test method based on gene expression of four markers related to the induction of skin sensitization; the assay uses commercially available reconstructed human epidermis. EpiSensA has exhibited an accuracy of 90% for 72 chemicals, including lipophilic chemicals and pre-/pro-haptens, when compared with the results of the murine local lymph node assay. In this work, a ring study was performed by one lead and two naive laboratories to evaluate the transferability, as well as within- and between-laboratory reproducibilities, of EpiSensA. Three non-coded chemicals (two lipophilic sensitizers and one non-sensitizer) were tested for the assessment of transferability and 10 coded chemicals (seven sensitizers and three non-sensitizers, including four lipophilic chemicals) were tested for the assessment of reproducibility. In the transferability phase, the non-coded chemicals (two sensitizers and one non-sensitizer) were correctly classified at the two naive laboratories, indicating that the EpiSensA protocol was transferred successfully. For the within-laboratory reproducibility, the data generated with three coded chemicals tested in three independent experiments in each laboratory gave consistent predictions within laboratories. For the between-laboratory reproducibility, 9 of the 10 coded chemicals tested once in each laboratory provided consistent predictions among the three laboratories. These results suggested that EpiSensA has good transferability, as well as within- and between-laboratory reproducibility. Copyright © 2018 John Wiley & Sons, Ltd.

  8. Open-ended versus guided laboratory activities:Impact on students' beliefs about experimental physics

    NASA Astrophysics Data System (ADS)

    Wilcox, Bethany R.; Lewandowski, H. J.

    2016-12-01

    Improving students' understanding of the nature of experimental physics is often an explicit or implicit goal of undergraduate laboratory physics courses. However, lab activities in traditional lab courses are typically characterized by highly structured, guided labs that often do not require or encourage students to engage authentically in the process of experimental physics. Alternatively, open-ended laboratory activities can provide a more authentic learning environment by, for example, allowing students to exercise greater autonomy in what and how physical phenomena are investigated. Engaging in authentic practices may be a critical part of improving students' beliefs around the nature of experimental physics. Here, we investigate the impact of open-ended activities in undergraduate lab courses on students' epistemologies and expectations about the nature of experimental physics, as well as their confidence and affect, as measured by the Colorado Learning Attitudes about Science Survey for Experimental Physics (E-CLASS). Using a national data set of student responses to the E-CLASS, we find that the inclusion of some open-ended lab activities in a lab course correlates with more expertlike postinstruction responses relative to courses that include only traditional guided lab activities. This finding holds when examining postinstruction E-CLASS scores while controlling for the variance associated with preinstruction scores, course level, student major, and student gender.

  9. Students' Understanding and Perceptions of Assigned Team Roles in a Classroom Laboratory Environment

    PubMed Central

    Ott, Laura E.; Kephart, Kerrie; Stolle-McAllister, Kathleen; LaCourse, William R.

    2018-01-01

    Using a cooperative learning framework in a quantitative reasoning laboratory course, students were assigned to static teams of four in which they adopted roles that rotated regularly. The roles included: team leader, protocol manager, data recorder, and researcher. Using a mixed-methods approach, we investigated students' perceptions of the team roles and specifically addressed students' understanding of the roles, students' beliefs in their ability to enact the roles, and whether working with assigned team roles supported the teams to work effectively and cohesively. Although students expressed confidence in their understanding of the team roles, their understanding differed from the initial descriptions. This suggests that students' understanding of team roles may be influenced by a variety of factors, including their experiences within their teams. Students also reported that some roles appeared to lack a purpose, implying that for roles to be successful, they must have a clear purpose. Finally, the fact that many students reported ignoring the team roles suggests that students do not perceive roles as a requirement for team productivity and cohesion. On the basis of these findings, we provide recommendations for instructors wishing to establish a classroom group laboratory environment. PMID:29681667

  10. Challenges in Small Screening Laboratories: SaaS to the rescue

    PubMed Central

    Lemmon, Vance P.; Jia, Yuanyuan; Shi, Yan; Holbrook, S. Douglas; Bixby, John L; Buchser, William

    2012-01-01

    The Miami Project to Cure Paralysis, part of the University of Miami Miller School of Medicine, includes a laboratory devoted to High Content Analysis (HCA) of neurons. The goal of the laboratory is to uncover signalling pathways, genes, compounds, or drugs that can be used to promote nerve growth. HCA permits the quantification of neuronal morphology, including the lengths and numbers of axons. HCA screening of various libraries on primary neurons requires a team-based approach, a variety of process steps and complex manipulations of cells and libraries to obtain meaningful results. HCA itself produces vast amounts of information including images, well-based data and cell-based phenotypic measures. Managing experimental workflow and library data, along with the extensive amount of experimental results is challenging. For academic laboratories generating large data sets from experiments using thousands of perturbagens, a laboratory information management system (LIMS) is the data tracking solution of choice. With both productivity and efficiency as driving rationales, the Miami Project has equipped its HCA laboratory with a Software As A Service (SAAS) LIMS to ensure the quality of its experiments and workflows. The article discusses this application in detail, and how the system was selected and integrated into the laboratory. The advantages of SaaS are described. PMID:21631415

  11. Regional Educational Laboratory Electronic Network Phase 2 System

    NASA Technical Reports Server (NTRS)

    Cradler, John

    1995-01-01

    The Far West Laboratory in collaboration with the other regional educational laboratories is establishing a regionally coordinated telecommunication network to electronically interconnect each of the ten regional laboratories with educators and education stakeholders from the school to the state level. For the national distributed information database, each lab is working with mid-level networks to establish a common interface for networking throughout the country and include topics of importance to education reform as assessment and technology planning.

  12. URBAN DECISION MAKING - THE FINDINGS FROM A CONFERENCE (CHICAGO, NOVEMBER 5-12, 1965). APPLICATIONS OF HUMAN RELATIONS LABORATORY TRAINING, NUMBER 1, 1967.

    ERIC Educational Resources Information Center

    FRANKLIN, PAULA; FRANKLIN, RICHARD

    THIS NATIONAL TRAINING LABORATORIES (NTL) CONFERENCE, DEPARTING SOMEWHAT FROM ITS USUAL EXPERIENCE-BASED LEARNING PROGRAMS, FOCUSED LABORATORY TRAINING METHODS ON THE DECISION-MAKING PROCESS IN URBAN COMMUNITY PROBLEM SOLVING. THE CONFERENCE PRESENTED THEORY, INFORMATION, AND OPINION ON THE NATURE OF CITIES AND THEIR DECISION-MAKING PROCESSES.…

  13. Bone development in laboratory mammals used in developmental toxicity studies.

    PubMed

    DeSesso, John M; Scialli, Anthony R

    2018-06-19

    Evaluation of the skeleton in laboratory animals is a standard component of developmental toxicology testing. Standard methods of performing the evaluation have been established, and modification of the evaluation using imaging technologies is under development. The embryology of the rodent, rabbit, and primate skeleton has been characterized in detail and summarized herein. The rich literature on variations and malformations in skeletal development that can occur in the offspring of normal animals and animals exposed to test articles in toxicology studies is reviewed. These perturbations of skeletal development include ossification delays, alterations in number, shape, and size of ossification centers, and alterations in numbers of ribs and vertebrae. Because the skeleton is undergoing developmental changes at the time fetuses are evaluated in most study designs, transient delays in development can produce apparent findings of abnormal skeletal structure. The determination of whether a finding represents a permanent change in embryo development with adverse consequences for the organism is important in study interpretation. Knowledge of embryological processes and schedules can assist in interpretation of skeletal findings. © 2018 The Authors. Birth Defects Research Published by Wiley Periodicals, Inc.

  14. Internal quality control indicators of cervical cytopathology exams performed in laboratories monitored by the External Quality Control Laboratory.

    PubMed

    Ázara, Cinara Zago Silveira; Manrique, Edna Joana Cláudio; Tavares, Suelene Brito do Nascimento; de Souza, Nadja Lindany Alves; Amaral, Rita Goreti

    2014-09-01

    To evaluate the impact of continued education provided by an external quality control laboratory on the indicators of internal quality control of cytopathology exams. The internal quality assurance indicators for cytopathology exams from 12 laboratories monitored by the External Quality Control Laboratory were evaluated. Overall, 185,194 exams were included, 98,133 of which referred to the period preceding implementation of a continued education program, while 87,061 referred to the period following this intervention. Data were obtained from the Cervical Cancer Database of the Brazilian National Health Service. Following implementation of the continued education program, the positivity index (PI) remained within recommended limits in four laboratories. In another four laboratories, the PI progressed from below the limits to within the recommended standards. In one laboratory, the PI remained low, in two laboratories, it remained very low, and in one, it increased from very low to low. The percentage of exams compatible with a high-grade squamous intraepithelial lesion (HSIL) remained within the recommended limits in five laboratories, while in three laboratories it progressed from below the recommended levels to >0.4% of the total number of satisfactory exams, and in four laboratories it remained below the standard limit. Both the percentage of atypical squamous cells of undetermined significance (ASC-US) in relation to abnormal exams, and the ratio between ASC-US and intraepithelial lesions remained within recommended levels in all the laboratories investigated. An improvement was found in the indicators represented by the positivity index and the percentage of exams compatible with a high-grade squamous intraepithelial lesion, showing that the role played by the external quality control laboratory in providing continued education contributed towards improving laboratory staff skills in detecting cervical cancer precursor lesions.

  15. Child Guidance for Child Caregivers: Student Laboratory Manual.

    ERIC Educational Resources Information Center

    Texas Tech Univ., Lubbock. Home Economics Curriculum Center.

    Designed to enhance student knowledge of and skills in child guidance in group care settings, this manual provides 50 laboratory experiences for five units. Units cover foundations and assumptions (2 laboratory experiences), developmental factors (8), indirect guidance (14), direct guidance (14), and strategies (12). Each unit includes performance…

  16. Students' motivation toward laboratory work in physiology teaching.

    PubMed

    Dohn, Niels Bonderup; Fago, Angela; Overgaard, Johannes; Madsen, Peter Teglberg; Malte, Hans

    2016-09-01

    The laboratory has been given a central role in physiology education, and teachers report that it is motivating for students to undertake experimental work on live animals or measuring physiological responses on the students themselves. Since motivation is a critical variable for academic learning and achievement, then we must concern ourselves with questions that examine how students engage in laboratory work and persist at such activities. The purpose of the present study was to investigate how laboratory work influences student motivation in physiology. We administered the Lab Motivation Scale to assess our students' levels of interest, willingness to engage (effort), and confidence in understanding (self-efficacy). We also asked students about the role of laboratory work for their own learning and their experience in the physiology laboratory. Our results documented high levels of interest, effort, and self-efficacy among the students. Correlation analyses were performed on the three motivation scales and exam results, yet a significant correlation was only found between self-efficacy in laboratory work and academic performance at the final exam. However, almost all students reported that laboratory work was very important for learning difficult concepts and physiological processes (e.g., action potential), as the hands-on experiences gave a more concrete idea of the learning content and made the content easier to remember. These results have implications for classroom practice as biology students find laboratory exercises highly motivating, despite their different personal interests and subject preferences. This highlights the importance of not replacing laboratory work by other nonpractical approaches, for example, video demonstrations or computer simulations. Copyright © 2016 The American Physiological Society.

  17. Clinical verification of genetic results returned to research participants: findings from a Colon Cancer Family Registry.

    PubMed

    Laurino, Mercy Y; Truitt, Anjali R; Tenney, Lederle; Fisher, Douglass; Lindor, Noralane M; Veenstra, David; Jarvik, Gail P; Newcomb, Polly A; Fullerton, Stephanie M

    2017-11-01

    The extent to which participants act to clinically verify research results is largely unknown. This study examined whether participants who received Lynch syndrome (LS)-related findings pursued researchers' recommendation to clinically verify results with testing performed by a CLIA-certified laboratory. The Fred Hutchinson Cancer Research Center site of the multinational Colon Cancer Family Registry offered non-CLIA individual genetic research results to select registry participants (cases and their enrolled relatives) from 2011 to 2013. Participants who elected to receive results were counseled on the importance of verifying results at a CLIA-certified laboratory. Twenty-six (76.5%) of the 34 participants who received genetic results completed 2- and 12-month postdisclosure surveys; 42.3% of these (11/26) participated in a semistructured follow-up interview. Within 12 months of result disclosure, only 4 (15.4%) of 26 participants reported having verified their results in a CLIA-certified laboratory; of these four cases, all research and clinical results were concordant. Reasons for pursuing clinical verification included acting on the recommendation of the research team and informing future clinical care. Those who did not verify results cited lack of insurance coverage and limited perceived personal benefit of clinical verification as reasons for inaction. These findings suggest researchers will need to address barriers to seeking clinical verification in order to ensure that the intended benefits of returning genetic research results are realized. © 2017 The Authors. Molecular Genetics & Genomic Medicine published by Wiley Periodicals, Inc.

  18. Safety in the Chemical Laboratory. Safety in the Laboratory: Are We Making Any Progress?

    ERIC Educational Resources Information Center

    McKusick, Blaine C.

    1987-01-01

    Reviews trends in laboratory safety found in both industrial and academic situations. Reports that large industrial labs generally have excellent safety programs but that, although there have been improvements, academia still lags behind industry in safety. Includes recommendations for improving lab safety. (ML)

  19. Translating a National Laboratory Strategic Plan into action through SLMTA in a district hospital laboratory in Botswana.

    PubMed

    Ntshambiwa, Keoratile; Ntabe-Jagwer, Winnie; Kefilwe, Chandapiwa; Samuel, Fredrick; Moyo, Sikhulile

    2014-01-01

    The Ministry of Health (MOH) of Botswana adopted Strengthening Laboratory Management Toward Accreditation (SLMTA), a structured quality improvement programme, as a key tool for the implementation of quality management systems in its public health laboratories. Coupled with focused mentorship, this programme aimed to help MOH achieve the goals of the National Laboratory Strategic Plan to provide quality and timely clinical diagnoses. This article describes the impact of implementing SLMTA in Sekgoma Memorial Hospital Laboratory (SMHL) in Serowe, Botswana. SLMTA implementation in SMHL included trainings, improvement projects, site visits and focused mentorship. To measure progress, audits using the Stepwise Laboratory Quality Improvement Process Towards Accreditation (SLIPTA) checklist were conducted at baseline and exit of the programme, with scores corresponding to a zero- to five-star scale. Turnaround times, customer satisfaction, and several other health service indicators were tracked. The laboratory scored 53% (zero stars) at the baseline audit and 80% (three stars) at exit. Nearly three years later, the laboratory scored 85% (four stars) in an official audit conducted by the African Society for Laboratory Medicine. Turnaround times became shorter after SLMTA implementation, with reductions ranging 19% to 52%; overall patient satisfaction increased from 56% to 73%; and clinician satisfaction increased from 41% to 72%. Improvements in inventory management led to decreases in discarded reagents, reducing losses from US $18 000 in 2011 to $40 in 2013. The SLMTA programme contributed to enhanced performance of the laboratory, which in turn yielded potential positive impacts for patient care at the hospital.

  20. Laboratory Techniques for the Blind

    ERIC Educational Resources Information Center

    Tombaugh, Dorothy

    1972-01-01

    Describes modifications of laboratory procedures for the BSCS Green Version biology, including dissection, microbiology, animal behavior, physiology, biochemistry, and genetics that make the methods suitable for direct experimentation by blind students. Discusses models as substitutes for microscopy. (AL)

  1. Theme: Land Laboratories--Urban Settings, Liability, Natural Resources Labs.

    ERIC Educational Resources Information Center

    Whaley, David, Ed.; And Others

    1994-01-01

    Includes "With a Little Imagination"; "From Fallow to Fertile"; "Operating a School Enterprise in Agriculture"; "Using a Nontraditional Greenhouse to Enhance Lab Instruction"; "Risk Management for Liability in Operating Land Laboratories"; "Working Land and Water Laboratory for Natural…

  2. Inquiry-Based Laboratory Activities in Electrochemistry: High School Students' Achievements and Attitudes

    NASA Astrophysics Data System (ADS)

    Acar Sesen, Burcin; Tarhan, Leman

    2013-02-01

    This study aimed to investigate the effects of inquiry-based laboratory activities on high school students' understanding of electrochemistry and attitudes towards chemistry and laboratory work. The participants were 62 high school students (average age 17 years) in an urban public high school in Turkey. Students were assigned to experimental ( N = 30) and control groups ( N = 32). The experimental group was taught using inquiry-based laboratory activities developed by the researchers and the control group was instructed using traditional laboratory activities. The results of the study indicated that instruction based on inquiry-based laboratory activities caused a significantly better acquisition of scientific concepts related to electrochemistry, and produced significantly higher positive attitudes towards chemistry and laboratory. In the light of the findings, it is suggested that inquiry-based laboratory activities should be developed and applied to promote students' understanding in chemistry subjects and to improve their positive attitudes.

  3. An Innovative Multimedia Approach to Laboratory Safety

    NASA Technical Reports Server (NTRS)

    Anderson, M. B.; Constant, K. P.

    1996-01-01

    A new approach for teaching safe laboratory practices has been developed for materials science laboratories at Iowa State university. Students are required to complete a computerized safety tutorial and pass an exam before working in the laboratory. The safety tutorial includes sections on chemical, electrical, radiation, and high temperature safety. The tutorial makes use of a variety of interactions, including 'assembly' interactions where a student is asked to drag and drop items with the mouse (either labels or pictures) to an appropriate place on the screen (sometimes in a specific order). This is extremely useful for demonstrating safe lab practices and disaster scenarios. Built into the software is a record tracking scheme so that a professor can access a file that records which students have completed the tutorial and their scores on the exam. This paper will describe the development and assessment of the safety tutorials.

  4. Cost analysis in the toxicology laboratory.

    PubMed

    Travers, E M

    1990-09-01

    The process of determining laboratory sectional and departmental costs and test costs for instrument-generated and manually generated reportable results for toxicology laboratories has been outlined in this article. It is hoped that the basic principles outlined in the preceding text will clarify and elucidate one of the most important areas needed for laboratory fiscal integrity and its survival in these difficult times for health care providers. The following general principles derived from this article are helpful aids for managers of toxicology laboratories. 1. To manage a cost-effective, efficient toxicology laboratory, several factors must be considered: the laboratory's instrument configuration, test turnaround time needs, the test menu offered, the analytic methods used, the cost of labor based on time expended and the experience and educational level of the staff, and logistics that determine specimen delivery time and costs. 2. There is a wide variation in costs for toxicologic methods, which requires that an analysis of capital (equipment) purchase and operational (test performance) costs be performed to avoid waste, purchase wisely, and determine which tests consume the majority of the laboratory's resources. 3. Toxicologic analysis is composed of many complex steps. Each step must be individually cost-accounted. Screening test results must be confirmed, and the cost for both steps must be included in the cost per reportable result. 4. Total costs will vary in the same laboratory and between laboratories based on differences in salaries paid to technical staff, differences in reagent/supply costs, the number of technical staff needed to operate the analyzer or perform the method, and the inefficient use of highly paid staff to operate the analyzer or perform the method. 5. Since direct test costs vary directly with the type and number of analyzers or methods and are dependent on the operational mode designed by the manufacturer, laboratory managers

  5. 142. ARAIII General plan of GCRE area, including electrical distribution ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    142. ARA-III General plan of GCRE area, including electrical distribution plan for power and lighting. Includes detail of floodlight and security lighting poles and fixtures. Aerojet-general 880-area/GCRE-406-1. Date: February 1958. Ineel index code no. 063-0406-00-013-102539. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  6. Phlebotomy, a bridge between laboratory and patient.

    PubMed

    Ialongo, Cristiano; Bernardini, Sergio

    2016-01-01

    The evidence-based paradigm has changed and evolved medical practice. Phlebotomy, which dates back to the age of ancient Greece, has gained experience through the evolution of medicine becoming a fundamental diagnostic tool. Nowadays it connects the patient with the clinical laboratory dimension building up a bridge. However, more often there is a gap between laboratory and phlebotomist that causes misunderstandings and burdens on patient safety. Therefore, the scope of this review is delivering a view of modern phlebotomy to "bridge" patient and laboratory. In this regard the paper describes devices, tools and procedures in the light of the most recent scientific findings, also discussing their impact on both quality of blood testing and patient safety. It also addresses the issues concerning medical aspect of venipuncture, like the practical approach to the superficial veins anatomy, as well as the management of the patient's compliance with the blood draw. Thereby, the clinical, technical and practical issues are treated with the same relevance throughout the entire paper.

  7. E-commerce application study and complementary services in the sector of laboratory diagnostics based on consumers' opinion.

    PubMed

    Kontis, Alexios-Patapios; Siassiakos, Konstantinos; Kaimakamis, Georgios; Lazakidou, Athina

    2010-01-01

    The field of the Laboratory Diagnostics (in vitro), a sector of the field of health services, constitutes an industrial market that includes activities of research, development, production and products distribution that are designated for laboratory use. These products are defined as techno-medical products including various categories of products such as simple medicines, advanced technological systems, etc. Despite the high performance, the enlargement and the increasing trends of the field, it is not recorded the expected progress in the methods and the ways of promotion, trading and supporting of these products in the market. The present paper aims at the investigation of the consumers' opinion and the specification of those services that are possible to be implemented in electronic services and commerce for a strongly competitive advantage for the enterprises of the sector. The analysis of the findings from the Consumer Purchase Decision Centres (CPDC) shows how important it is to implement web-based applications in the proposed services.

  8. Guide for Training Medical Laboratory Technicians. Fourth Edition.

    ERIC Educational Resources Information Center

    American Medical Technologists, Park Ridge, IL.

    This document is intended to assist educators in the development of medical laboratory technician training programs. The following elements are included in the document: (1) an introduction; (2) the American Medical Technologists' Code of Ethics; (3) suggested curricula for medical laboratory technician programs for a 12-month course and an…

  9. Selecting automation for the clinical chemistry laboratory.

    PubMed

    Melanson, Stacy E F; Lindeman, Neal I; Jarolim, Petr

    2007-07-01

    Laboratory automation proposes to improve the quality and efficiency of laboratory operations, and may provide a solution to the quality demands and staff shortages faced by today's clinical laboratories. Several vendors offer automation systems in the United States, with both subtle and obvious differences. Arriving at a decision to automate, and the ensuing evaluation of available products, can be time-consuming and challenging. Although considerable discussion concerning the decision to automate has been published, relatively little attention has been paid to the process of evaluating and selecting automation systems. To outline a process for evaluating and selecting automation systems as a reference for laboratories contemplating laboratory automation. Our Clinical Chemistry Laboratory staff recently evaluated all major laboratory automation systems in the United States, with their respective chemistry and immunochemistry analyzers. Our experience is described and organized according to the selection process, the important considerations in clinical chemistry automation, decisions and implementation, and we give conclusions pertaining to this experience. Including the formation of a committee, workflow analysis, submitting a request for proposal, site visits, and making a final decision, the process of selecting chemistry automation took approximately 14 months. We outline important considerations in automation design, preanalytical processing, analyzer selection, postanalytical storage, and data management. Selecting clinical chemistry laboratory automation is a complex, time-consuming process. Laboratories considering laboratory automation may benefit from the concise overview and narrative and tabular suggestions provided.

  10. Evaluation of Non-Laboratory and Laboratory Prediction Models for Current and Future Diabetes Mellitus: A Cross-Sectional and Retrospective Cohort Study

    PubMed Central

    Hahn, Seokyung; Moon, Min Kyong; Park, Kyong Soo; Cho, Young Min

    2016-01-01

    Background Various diabetes risk scores composed of non-laboratory parameters have been developed, but only a few studies performed cross-validation of these scores and a comparison with laboratory parameters. We evaluated the performance of diabetes risk scores composed of non-laboratory parameters, including a recently published Korean risk score (KRS), and compared them with laboratory parameters. Methods The data of 26,675 individuals who visited the Seoul National University Hospital Healthcare System Gangnam Center for a health screening program were reviewed for cross-sectional validation. The data of 3,029 individuals with a mean of 6.2 years of follow-up were reviewed for longitudinal validation. The KRS and 16 other risk scores were evaluated and compared with a laboratory prediction model developed by logistic regression analysis. Results For the screening of undiagnosed diabetes, the KRS exhibited a sensitivity of 81%, a specificity of 58%, and an area under the receiver operating characteristic curve (AROC) of 0.754. Other scores showed AROCs that ranged from 0.697 to 0.782. For the prediction of future diabetes, the KRS exhibited a sensitivity of 74%, a specificity of 54%, and an AROC of 0.696. Other scores had AROCs ranging from 0.630 to 0.721. The laboratory prediction model composed of fasting plasma glucose and hemoglobin A1c levels showed a significantly higher AROC (0.838, P < 0.001) than the KRS. The addition of the KRS to the laboratory prediction model increased the AROC (0.849, P = 0.016) without a significant improvement in the risk classification (net reclassification index: 4.6%, P = 0.264). Conclusions The non-laboratory risk scores, including KRS, are useful to estimate the risk of undiagnosed diabetes but are inferior to the laboratory parameters for predicting future diabetes. PMID:27214034

  11. Revitalizing chemistry laboratory instruction

    NASA Astrophysics Data System (ADS)

    McBride, Phil Blake

    This dissertation involves research in three major domains of chemical education as partial fulfillment of the requirements for the Ph.D. program in chemistry at Miami University with a major emphasis on chemical education, and concurrent study in organic chemistry. Unit I, Development and Assessment of a Column Chromatography Laboratory Activity, addresses the domain of Instructional Materials Development and Testing. This unit outlines the process of developing a publishable laboratory activity, testing and revising that activity, and subsequently sharing that activity with the chemical education community. A laboratory activity focusing on the separation of methylene blue and sodium fluorescein was developed to demonstrate the effects of both the stationary and mobile phase in conducting a separation. Unit II, Bringing Industry to the Laboratory, addresses the domain of Curriculum Development and Testing. This unit outlines the development of the Chemistry of Copper Mining module, which is intended for use in high school or undergraduate college chemistry. The module uses the learning cycle approach to present the chemistry of the industrial processes of mining copper to the students. The module includes thirteen investigations (three of which are web-based and ten which are laboratory experiments) and an accompanying interactive CD-ROM, which provides an explanation of the chemistry used in copper mining with a virtual tour of an operational copper mine. Unit III, An Alternative Method of Teaching Chemistry. Integrating Lecture and the Laboratory, is a project that addresses the domain of Research in Student Learning. Fundamental Chemistry was taught at Eastern Arizona College as an integrated lecture/laboratory course that met in two-hour blocks on Monday, Wednesday, and Friday. The students taking this integrated course were compared with students taking the traditional 1-hour lectures held on Monday, Wednesday, and Friday, with accompanying 3-hour lab on

  12. Affordances of Instrumentation in General Chemistry Laboratories

    ERIC Educational Resources Information Center

    Sherman, Kristin Mary Daniels

    2010-01-01

    The purpose of this study is to find out what students in the first chemistry course at the undergraduate level (general chemistry for science majors) know about the affordances of instrumentation used in the general chemistry laboratory and how their knowledge develops over time. Overall, students see the PASCO(TM) system as a useful and accurate…

  13. Improving the Design of Laboratory Worksheets.

    ERIC Educational Resources Information Center

    McDowell, E. T.; Wadding, R. E. L.

    1985-01-01

    Describes a technique to improve the adaptation, development, and utilization of laboratory worksheets. Two sample worksheets (on decomposition of ethanol and on solubility of potassium chloride) are included. (JN)

  14. Electronic laboratory notebooks progress and challenges in implementation.

    PubMed

    Machina, Hari K; Wild, David J

    2013-08-01

    Electronic laboratory notebooks (ELNs) are increasingly replacing paper notebooks in life science laboratories, including those in industry, academic settings, and hospitals. ELNs offer significant advantages over paper notebooks, but adopting them in a predominantly paper-based environment is usually disruptive. The benefits of ELN increase when they are integrated with other laboratory informatics tools such as laboratory information management systems, chromatography data systems, analytical instrumentation, and scientific data management systems, but there is no well-established path for effective integration of these tools. In this article, we review and evaluate some of the approaches that have been taken thus far and also some radical new methods of integration that are emerging.

  15. Safety and health practice among laboratory staff in Malaysian education sector

    NASA Astrophysics Data System (ADS)

    Husna Che Hassan, Nurul; Rasdan Ismail, Ahmad; Kamilah Makhtar, Nor; Azwadi Sulaiman, Muhammad; Syuhadah Subki, Noor; Adilah Hamzah, Noor

    2017-10-01

    Safety is the most important issue in industrial sector such as construction and manufacturing. Recently, the increasing number of accident cases reported involving school environment shows the important of safety issues in education sector. Safety awareness among staff in this sector is crucial in order to find out the method to prevent the accident occurred in future. This study was conducted to analyze the knowledge of laboratory staff in term of safety and health practice in laboratory. Survey questionnaires were distributing among 255 of staff laboratory from ten District Education Offices in Kelantan. Descriptive analysis shows that the understanding of safety and health practice are low while doing some job activities in laboratory. Furthermore, some of the staff also did not implemented safety practice that may contribute to unplanned event occur in laboratory. Suggestion that the staff at laboratory need to undergo on Occupational Safety and Health training to maintain and create safe environment in workplaces.

  16. Laboratory Connections. Gas Monitoring Transducers.

    ERIC Educational Resources Information Center

    Powers, Michael H.

    1988-01-01

    Discusses three types of sensors; pressure, gas detection, and relative humidity. Explains their use for laboratory measurements of gas pressure and detection of specific gaseous species. Shows diagrams of devices and circuits along with examples and applications including microcomputer interfacing. (RT)

  17. Felsenkeller shallow-underground accelerator laboratory for nuclear astrophysics

    NASA Astrophysics Data System (ADS)

    Bemmerer, D.; Cowan, T. E.; Gohl, S.; Ilgner, C.; Junghans, A. R.; Reinhardt, T. P.; Rimarzig, B.; Reinicke, S.; Röder, M.; Schmidt, K.; Schwengner, R.; Stöckel, K.; Szücs, T.; Takács, M.; Wagner, A.; Wagner, L.; Zuber, K.

    2015-05-01

    Favored by the low background in underground laboratories, low-background accelerator-based experiments are an important tool to study nuclear reactions involving stable charged particles. This technique has been used for many years with great success at the 0.4 MV LUNA accelerator in the Gran Sasso laboratory in Italy, proteced from cosmic rays by 1400 m of rock. However, the nuclear reactions of helium and carbon burning and the neutron source reactions for the astrophysical s-process require higher beam energies than those available at LUNA. Also the study of solar fusion reactions necessitates new data at higher energies. As a result, in the present NuPECC long range plan for nuclear physics in Europe, the installation of one or more higher-energy underground accelerators is strongly recommended. An intercomparison exercise has been carried out using the same HPGe detector in a typical nuclear astrophysics setup at several sites, including the Dresden Felsenkeller underground laboratory. It was found that its rock overburden of 45m rock, together with an active veto against the remaining muon flux, reduces the background to a level that is similar to the deep underground scenario. Based on this finding, a used 5 MV pelletron tandem with 250 μA upcharge current and external sputter ion source has been obtained and transported to Dresden. Work on an additional radio-frequency ion source on the high voltage terminal is underway. The project is now fully funded. The installation of the accelerator in the Felsenkeller is expected for the near future. The status of the project and the planned access possibilities for external users will be reported.

  18. A Listening Laboratory Designed from Cognitive Learning Principles at Evergreen Valley College.

    ERIC Educational Resources Information Center

    Johnson, Tanya

    A listening laboratory was developed at Evergreen Valley College (EVC) in accordance with procedures used at the college's individualized instruction laboratory. Steps taken in developing the laboratory included: (1) the director of the Learning Center Instructional Laboratory was interviewed to determine the procedure for establishing the…

  19. Why Teachers Find It Difficult to Include Students with EBD in Mainstream Classes

    ERIC Educational Resources Information Center

    Gidlund, Ulrika

    2018-01-01

    In Sweden, teachers in mainstream schools show frustration and insecurity about how to organise education for inclusion and diversity. This article contributes to the understanding of how they articulate their view of the advantages and disadvantages of including students with EBD in mainstream classes. To study teachers' understanding, an…

  20. An Upper Level Laboratory Course of Integrated Experiments

    ERIC Educational Resources Information Center

    Rose, T. L.; Seyse, R. J.

    1974-01-01

    Discusses the development of a one-year laboratory course in an effort to provide a link between traditional laboratories devoted to a single area of chemistry and the total involvement of a single narrow research project. Included are outlines of 32-hour lectures and 11 experiments performed in the integrated course. (CC)

  1. Laboratory Directed Research and Development FY-15 Annual Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pillai, Rekha Sukamar

    The Laboratory Directed Research and Development (LDRD) Program at Idaho National Laboratory (INL) reports its status to the U.S. Department of Energy (DOE) by March of each year. The program operates under the authority of DOE Order 413.2B, “Laboratory Directed Research and Development” (April 19, 2006), which establishes DOE’s requirements for the program while providing the laboratory director broad flexibility for program implementation. LDRD funds are obtained through a charge to all INL programs. This report includes summaries of all INL LDRD research activities supported during Fiscal Year (FY) 2015.

  2. Exoplanet Coronagraph Shaped Pupil Masks and Laboratory Scale Star Shade Masks: Design, Fabrication and Characterization

    NASA Technical Reports Server (NTRS)

    Balasubramanian, Kunjithapatha; White, Victor; Yee, Karl; Echternach, Pierre; Muller, Richard; Dickie, Matthew; Cady, Eric; Mejia Prada, Camilo; Ryan, Daniel; Poberezhskiy, Ilya; hide

    2015-01-01

    Star light suppression technologies to find and characterize faint exoplanets include internal coronagraph instruments as well as external star shade occulters. Currently, the NASA WFIRST-AFTA mission study includes an internal coronagraph instrument to find and characterize exoplanets. Various types of masks could be employed to suppress the host star light to about 10 -9 level contrast over a broad spectrum to enable the coronagraph mission objectives. Such masks for high contrast internal coronagraphic imaging require various fabrication technologies to meet a wide range of specifications, including precise shapes, micron scale island features, ultra-low reflectivity regions, uniformity, wave front quality, achromaticity, etc. We present the approaches employed at JPL to produce pupil plane and image plane coronagraph masks by combining electron beam, deep reactive ion etching, and black silicon technologies with illustrative examples of each, highlighting milestone accomplishments from the High Contrast Imaging Testbed (HCIT) at JPL and from the High Contrast Imaging Lab (HCIL) at Princeton University. We also present briefly the technologies applied to fabricate laboratory scale star shade masks.

  3. Exoplanet coronagraph shaped pupil masks and laboratory scale star shade masks: design, fabrication and characterization

    NASA Astrophysics Data System (ADS)

    Balasubramanian, Kunjithapatham; White, Victor; Yee, Karl; Echternach, Pierre; Muller, Richard; Dickie, Matthew; Cady, Eric; Mejia Prada, Camilo; Ryan, Daniel; Poberezhskiy, Ilya; Zhou, Hanying; Kern, Brian; Riggs, A. J.; Zimmerman, Neil T.; Sirbu, Dan; Shaklan, Stuart; Kasdin, Jeremy

    2015-09-01

    Star light suppression technologies to find and characterize faint exoplanets include internal coronagraph instruments as well as external star shade occulters. Currently, the NASA WFIRST-AFTA mission study includes an internal coronagraph instrument to find and characterize exoplanets. Various types of masks could be employed to suppress the host star light to about 10-9 level contrast over a broad spectrum to enable the coronagraph mission objectives. Such masks for high contrast internal coronagraphic imaging require various fabrication technologies to meet a wide range of specifications, including precise shapes, micron scale island features, ultra-low reflectivity regions, uniformity, wave front quality, achromaticity, etc. We present the approaches employed at JPL to produce pupil plane and image plane coronagraph masks by combining electron beam, deep reactive ion etching, and black silicon technologies with illustrative examples of each, highlighting milestone accomplishments from the High Contrast Imaging Testbed (HCIT) at JPL and from the High Contrast Imaging Lab (HCIL) at Princeton University. We also present briefly the technologies applied to fabricate laboratory scale star shade masks.

  4. Laboratory for Extraterrestrial Physics

    NASA Technical Reports Server (NTRS)

    Vondrak, Richard R. (Technical Monitor)

    2001-01-01

    The NASA Goddard Space Flight Center (GSFC) Laboratory for Extraterrestrial Physics (LEP) performs experimental and theoretical research on the heliosphere, the interstellar medium, and the magnetospheres and upper atmospheres of the planets, including Earth. LEP space scientists investigate the structure and dynamics of the magnetospheres of the planets including Earth. Their research programs encompass the magnetic fields intrinsic to many planetary bodies as well as their charged-particle environments and plasma-wave emissions. The LEP also conducts research into the nature of planetary ionospheres and their coupling to both the upper atmospheres and their magnetospheres. Finally, the LEP carries out a broad-based research program in heliospheric physics covering the origins of the solar wind, its propagation outward through the solar system all the way to its termination where it encounters the local interstellar medium. Special emphasis is placed on the study of solar coronal mass ejections (CME's), shock waves, and the structure and properties of the fast and slow solar wind. LEP planetary scientists study the chemistry and physics of planetary stratospheres and tropospheres and of solar system bodies including meteorites, asteroids, comets, and planets. The LEP conducts a focused program in astronomy, particularly in the infrared and in short as well as very long radio wavelengths. We also perform an extensive program of laboratory research, including spectroscopy and physical chemistry related to astronomical objects. The Laboratory proposes, develops, fabricates, and integrates experiments on Earth-orbiting, planetary, and heliospheric spacecraft to measure the characteristics of planetary atmospheres and magnetic fields, and electromagnetic fields and plasmas in space. We design and develop spectrometric instrumentation for continuum and spectral line observations in the x-ray, gamma-ray, infrared, and radio regimes; these are flown on spacecraft to study

  5. Laboratory Automation and Intra-Laboratory Turnaround Time: Experience at the University Hospital Campus Bio-Medico of Rome.

    PubMed

    Angeletti, Silvia; De Cesaris, Marina; Hart, Jonathan George; Urbano, Michele; Vitali, Massimiliano Andrea; Fragliasso, Fulvio; Dicuonzo, Giordano

    2015-12-01

    Intra-laboratory turnaround time (TAT) is a key indicator of laboratory performance. Improving TAT is a complex task requiring staff education, equipment acquisition, and adequate TAT monitoring. The aim of the present study was to evaluate the intra-laboratory TAT after laboratory automation implementation (June 2013-June 2014) and to compare it to that in the preautomation period (July 2012-May 2013). Intra-laboratory TAT was evaluated both as the mean TAT registered and the percentage of outlier (OP) exams. The mean TAT was 36, 38, and 34 min during the study periods, respectively. These values respected the goal TAT established at 45 min. The OP, calculated at 45 min as well as at 60 min, decreased from 26 to 21 and from 11 to 5, respectively. From a focused analysis on blood count cell, troponin I, and prothrombin (PT) test, TAT improvement was more evident for tests requiring longer preanalytical process. The follow-up of TAT from June 2013 to June 2014 revealed the reduction of the mean TAT as well as of the OP exams after automation implementation and that automation more strongly affects the test in the preanalytical phase including centrifugation of the sample, such as troponin I and PT. © 2015 Society for Laboratory Automation and Screening.

  6. The role of total laboratory automation in a consolidated laboratory network.

    PubMed

    Seaberg, R S; Stallone, R O; Statland, B E

    2000-05-01

    In an effort to reduce overall laboratory costs and improve overall laboratory efficiencies at all of its network hospitals, the North Shore-Long Island Health System recently established a Consolidated Laboratory Network with a Core Laboratory at its center. We established and implemented a centralized Core Laboratory designed around the Roche/Hitachi CLAS Total Laboratory Automation system to perform the general and esoteric laboratory testing throughout the system in a timely and cost-effective fashion. All remaining STAT testing will be performed within the Rapid Response Laboratories (RRLs) at each of the system's hospitals. Results for this laboratory consolidation and implementation effort demonstrated a decrease in labor costs and improved turnaround time (TAT) at the core laboratory. Anticipated system savings are approximately $2.7 million. TATs averaged 1.3 h within the Core Laboratory and less than 30 min in the RRLs. When properly implemented, automation systems can reduce overall laboratory expenses, enhance patient services, and address the overall concerns facing the laboratory today: job satisfaction, decreased length of stay, and safety. The financial savings realized are primarily a result of labor reductions.

  7. Segmental arterial mediolysis: findings at computed tomography angiography.

    PubMed

    García-Barquín, P; Bilbao, J I; Quílez, A; Aragón, M S; Vivas, I

    To review the principal findings on computed tomography angiography for segmental arterial mediolysis, and to emphasize the points that help to differentiate it from other vasculopathies such as vasculitis. We also review the protocols for follow-up and the various treatment options. Segmental arterial mediolysis is a rare disease that is defined as a non-atherosclerotic, non-hereditary, and non-inflammatory vasculopathy characterized by lysis of the medial layer of the arterial wall. It should be suspected in middle-aged patients with aneurysms, dissections, or spontaneous ruptures of visceral arteries of unknown etiology who do not fulfill the clinical and laboratory criteria for vasculitis. The arteries of the abdominal organs are the most commonly affected, including the arteries of the celiac trunk and the superior and inferior mesenteric arteries. Radiologically, segmental arterial mediolysis can present as arterial dilation; single or multiple, saccular or fusiform aneurysms; stenoses; or dissections. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Myoglobin Structure and Function: A Multiweek Biochemistry Laboratory Project

    ERIC Educational Resources Information Center

    Silverstein, Todd P.; Kirk, Sarah R.; Meyer, Scott C.; Holman, Karen L. McFarlane

    2015-01-01

    We have developed a multiweek laboratory project in which students isolate myoglobin and characterize its structure, function, and redox state. The important laboratory techniques covered in this project include size-exclusion chromatography, electrophoresis, spectrophotometric titration, and FTIR spectroscopy. Regarding protein structure,…

  9. Reduction of Hazardous Waste from High School Chemistry Laboratories.

    ERIC Educational Resources Information Center

    Wahl, George H., Jr., Ed.

    This document provides teachers with sources of useful information and new ideas about the high school chemistry laboratory program. Chapters included are: (1) "Introduction" describing the philosophy and specific objectives of this project; (2) "Importance of Laboratory Work"; (3) "Chemistry Lab Outline" listing…

  10. Managing laboratory automation in a changing pharmaceutical industry

    PubMed Central

    Rutherford, Michael L.

    1995-01-01

    The health care reform movement in the USA and increased requirements by regulatory agencies continue to have a major impact on the pharmaceutical industry and the laboratory. Laboratory management is expected to improve effciency by providing more analytical results at a lower cost, increasing customer service, reducing cycle time, while ensuring accurate results and more effective use of their staff. To achieve these expectations, many laboratories are using robotics and automated work stations. Establishing automated systems presents many challenges for laboratory management, including project and hardware selection, budget justification, implementation, validation, training, and support. To address these management challenges, the rationale for project selection and implementation, the obstacles encountered, project outcome, and learning points for several automated systems recently implemented in the Quality Control Laboratories at Eli Lilly are presented. PMID:18925014

  11. 2011 Mars Science Laboratory Mission Design Overview

    NASA Technical Reports Server (NTRS)

    Abilleira, Fernando

    2010-01-01

    Scheduled to launch in the fall of 2011 with arrival at Mars occurring in the summer of 2012, NASA's Mars Science Laboratory will explore and assess whether Mars ever had conditions capable of supporting microbial life. In order to achieve its science objectives, the Mars Science Laboratory will be equipped with the most advanced suite of instruments ever sent to the surface of the Red Planet. Delivering the next mobile science laboratory safely to the surface of Mars has various key challenges derived from a strict set of requirements which include launch vehicle performance, spacecraft mass, communications coverage during Entry, Descent, and Landing, atmosphere-relative entry speeds, latitude accessibility, and dust storm season avoidance among others. The Mars Science Laboratory launch/arrival strategy selected after careful review satisfies all these mission requirements.

  12. Early visual language exposure and emergent literacy in preschool deaf children: findings from a national longitudinal study.

    PubMed

    Allen, Thomas E; Letteri, Amy; Choi, Song Hoa; Dang, Daqian

    2014-01-01

    Brief review is provided of recent research on the impact of early visual language exposure on a variety of developmental outcomes, including literacy, cognition, and social adjustment. This body of work points to the great importance of giving young deaf children early exposure to a visual language as a critical precursor to the acquisition of literacy. Four analyses of data from the Visual Language and Visual Learning (VL2) Early Education Longitudinal Study are summarized. Each confirms findings from previously published laboratory findings and points to the positive effects of early sign language on, respectively, letter knowledge, social adaptability, sustained visual attention, and cognitive-behavioral milestones necessary for academic success. The article concludes with a consideration of the qualitative similarity hypothesis and a finding that the hypothesis is valid, but only if it can be presented as being modality independent.

  13. 41. OPERATING CORRIDOR PLAN AND SECTIONS, INCLUDING SOME ISOMETRIC DETAILS. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    41. OPERATING CORRIDOR PLAN AND SECTIONS, INCLUDING SOME ISOMETRIC DETAILS. INEEL DRAWING NUMBER 200-0633-00-287-106455. FLUOR NUMBER 5775-CPP-633-P-60 - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID

  14. Strengths of the Northwell Health Laboratory Service Line

    PubMed Central

    Balfour, Erika; Stallone, Robert; Castagnaro, Joseph; Poczter, Hannah; Schron, Deborah; Martone, James; Breining, Dwayne; Simpkins, Henry; Neglia, Tom; Kalish, Paul

    2016-01-01

    From 2009 to 2015, the laboratories of the 19-hospital North Shore-LIJ Health System experienced 5 threatened interruptions in service and supported 2 regional health-care providers with threatened interruptions in their laboratory service. We report our strategies to maintain laboratory performance during these events, drawing upon the strengths of our integrated laboratory service line. Established in 2009, the laboratory service line has unified medical and administrative leadership and system-wide divisional structure, quality management, and standardization of operations and procedures. Among many benefits, this governance structure enabled the laboratories to respond to a series of unexpected events. Specifically, at our various service sites, the laboratories dealt with pandemic (2009), 2 floods (2010, 2012), 2 fires (2010, 2015), and laboratory floor subsidence (2013). We were also asked to provide support for a regional physician network facing abrupt loss of testing services from closure of another regional clinical laboratory (2010) and to intervene for a non-health system hospital threatened with closure owing to noncompliance of laboratory operations (2012). In all but a single instance, patient care was served without interruption in service. In the last instance, fire interrupted laboratory services for 30 minutes. We conclude that in a large integrated health system, threats to continuous laboratory operations are not infrequent when measured on an annual basis. While most threats are from external physical circumstances, some emanate from unexpected administrative events. A strong laboratory governance mechanism that includes unified medical and administrative leadership across the entirety of the laboratory service line enables successful responses to these threats. PMID:28725768

  15. Innovative ventilation system for animal anatomy laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lacey, D.R.; Smith, D.C.

    1997-04-01

    A unique ventilation system was designed and built to reduce formaldehyde fumes in the large animal anatomy lab at the Vet Medical Center at Cornell University. The laboratory includes four rooms totaling 5,500 ft{sup 2}. The main room has 2,300 ft{sup 2} and houses the laboratory where up to 60 students dissect as many as 12 horses at a time. Other rooms are a cold storage locker, an animal preparation room and a smaller lab for specialized instruction. The large animal anatomy laboratory has a history of air quality complaints despite a fairly high ventilation rate of over 10 airmore » changes/hour. The horses are embalmed, creating a voluminous source of formaldehyde and phenol vapors. Budget constraints and increasingly stringent exposure limits for formaldehyde presented a great challenge to design a ventilation system that yields acceptable air quality. The design solution included two innovative elements: air-to-air heat recovery, and focused ventilation.« less

  16. Clinical, hematological, and biochemical findings in puppies with coronavirus and parvovirus enteritis

    PubMed Central

    Castro, Tatiana X.; Cubel Garcia, Rita de Cássia N.; Gonçalves, Luciana P. S.; Costa, Erika M.; Marcello, Gracy C.G.; Labarthe, Norma V.; Mendes-de-Almeida, Flavya

    2013-01-01

    The clinical and laboratory findings in puppies naturally infected with canine coronavirus (CCoV) and/or canine parvovirus (CPV) were compared with findings in uninfected puppies. Lymphopenia was the only parameter related to CCoV infection that was statistically significant; vomiting, anorexia, lethargy, hemorrhagic fluid diarrhea, leukopenia, lymphopenia, thrombocytopenia, hypoglycemia, and hypoproteinemia were correlated with CPV infection. PMID:24155496

  17. Expansion of Surveillance for Vaccine-preventable Diseases: Building on the Global Polio Laboratory Network and the Global Measles and Rubella Laboratory Network Platforms.

    PubMed

    Mulders, Mick N; Serhan, Fatima; Goodson, James L; Icenogle, Joseph; Johnson, Barbara W; Rota, Paul A

    2017-07-01

    Laboratory networks were established to provide accurate and timely laboratory confirmation of infections, an essential component of disease surveillance systems. The World Health Organization (WHO) coordinates global laboratory surveillance of vaccine-preventable diseases (VPDs), including polio, measles and rubella, yellow fever, Japanese encephalitis, rotavirus, and invasive bacterial diseases. In addition to providing high-quality laboratory surveillance data to help guide disease control, elimination, and eradication programs, these global networks provide capacity-building and an infrastructure for public health laboratories. There are major challenges with sustaining and expanding the global laboratory surveillance capacity: limited resources and the need for expansion to meet programmatic goals. Here, we describe the WHO-coordinated laboratory networks supporting VPD surveillance and present a plan for the further development of these networks. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.

  18. Actinomadura Species: Laboratory Maintenance and Ribosome Engineering.

    PubMed

    Dhakal, Dipesh; Chung, Nguyen Thanh; Rayamajhi, Vijay; Sohng, Jae Kyung

    2017-02-06

    Actinomadura spp. are aerobic, Gram-positive, catalase-positive, non-acid fast, non-motile actinomycetes. Some species of Actinomadura are associated with opportunistic infections in humans. However, many bioactive compounds with pharmaceutical applications can be isolated from various Actinomadura spp. This unit includes general protocols for the laboratory maintenance of Actinomadura spp., including growth in liquid medium, growth on solid agar, long-term storage, and generation of a higher producing strain by ribosome engineering. Actinomadura hibisca P157-2 is used as a prototype for explaining the considerations for efficient laboratory maintenance of Actinomadura spp. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  19. Challenges to laboratory hematology practice: Egypt perspective.

    PubMed

    Rizk, S H

    2018-05-01

    Laboratory hematology is an integral part of all clinical laboratories along the extensive healthcare facilities in Egypt. The aim of this review is to portrait the laboratory hematology practice in Egypt including its unique socioeconomic background, blood disease pattern, education and training, regulatory oversight, and the related challenges. Current practice varies widely between different parts of the healthcare system in terms of the range of tests, applied techniques, workforce experience, and quality of service. The national transfusion service (NBTS) in Egypt has been recently upgraded and standardized according to the World Health Organization (WHO) guidelines. Formal postgraduate education roughly follows the British system. Laboratory hematology specialization is achieved through 2-3 years masters' degree followed by 2-4 years doctorate degree in clinical pathology with training and research in hematology. Improvement of laboratory hematology education is recently undergoing a reform as a part of the modernization of higher education policy and following the standards developed by the National Quality Assurance and Accreditation Agency (NQAAA). Accreditation of medical laboratories is recently progressing with the development of the "Egyptian Accreditation Council" (EGAC) as the sole accreditation body system and training of assessors. Current laboratory system has many challenges, some are related to the inadequate system performance, and others are unique to laboratory hematology issues. The rapid technological advances and therapeutic innovations in hematology practice call for an adapting laboratory system with continuous upgrading. © 2018 John Wiley & Sons Ltd.

  20. Crew Systems Laboratory/Building 7. Historical Documentation

    NASA Technical Reports Server (NTRS)

    Slovinac, Patricia

    2011-01-01

    Building 7 is managed by the Crew and Thermal Systems Division of the JSC Engineering Directorate. Originally named the Life Systems Laboratory, it contained five major test facilities: two advanced environmental control laboratories and three human-rated vacuum chambers (8 , 11 , and the 20 ). These facilities supported flight crew familiarization and the testing and evaluation of hardware used in the early manned spaceflight programs, including Gemini, Apollo, and the ASTP.

  1. Strategies for laboratory cost containment and for pathologist shortage: centralised pathology laboratories with microwave-stimulated histoprocessing and telepathology.

    PubMed

    Leong, Anthony S Y; Leong, F Joel W M

    2005-02-01

    The imposition of laboratory cost containment, often from external forces, dictates the necessity to develop strategies to meet laboratory cost savings. In addition, the national and worldwide shortage of anatomical pathologists makes it imperative to examine our current practice and laboratory set-ups. Some of the strategies employed in other areas of pathology and laboratory medicine include improvements in staff productivity and the adoption of technological developments that reduce manual intervention. However, such opportunities in anatomical pathology are few and far between. Centralisation has been an effective approach in bringing economies of scale, the adoption of 'best practices' and the consolidation of pathologists, but this has not been possible in anatomical pathology because conventional histoprocessing takes a minimum of 14 hours and clinical turnaround time requirements necessitate that the laboratory and pathologist be in proximity and on site. While centralisation of laboratories for clinical chemistry, haematology and even microbiology has been successful in Australia and other countries, the essential requirements for anatomical pathology laboratories are different. In addition to efficient synchronised courier networks, a method of ultra-rapid tissue processing and some expedient system of returning the prepared tissue sections to the remote laboratory are essential to maintain the turnaround times mandatory for optimal clinical management. The advent of microwave-stimulated tissue processing that can be completed in 30-60 minutes and the immediate availability of compressed digital images of entire tissue sections via telepathology completes the final components of the equation necessary for making centralised anatomical pathology laboratories a reality.

  2. Artist's Concept of NASA's Propulsion Research Laboratory

    NASA Technical Reports Server (NTRS)

    2002-01-01

    A new, world-class laboratory for research into future space transportation technologies is under construction at the Marshall Space Flight Center (MSFC) in Huntsville, AL. The state-of-the-art Propulsion Research Laboratory will serve as a leading national resource for advanced space propulsion research. Its purpose is to conduct research that will lead to the creation and development of irnovative propulsion technologies for space exploration. The facility will be the epicenter of the effort to move the U.S. space program beyond the confines of conventional chemical propulsion into an era of greatly improved access to space and rapid transit throughout the solar system. The Laboratory is designed to accommodate researchers from across the United States, including scientists and engineers from NASA, the Department of Defense, the Department of Energy, universities, and industry. The facility, with 66,000 square feet of useable laboratory space, will feature a high degree of experimental capability. Its flexibility will allow it to address a broad range of propulsion technologies and concepts, such as plasma, electromagnetic, thermodynamic, and propellantless propulsion. An important area of emphasis will be development and utilization of advanced energy sources, including highly energetic chemical reactions, solar energy, and processes based on fission, fusion, and antimatter. The Propulsion Research Laboratory is vital for developing the advanced propulsion technologies needed to open up the space frontier, and will set the stage of research that could revolutionize space transportation for a broad range of applications.

  3. Micromachined probes for laboratory plasmas

    NASA Astrophysics Data System (ADS)

    Chiang, Franklin Changta

    As we begin to find more applications for plasmas in our everyday lives, the ability to characterize and understand their inner workings becomes increasingly important. Much of our current understanding of plasma physics comes from investigations conducted in diffuse, outer space plasmas where experimenters have no control over the environment or experimental conditions and one measures interesting phenomena only by chance when the spacecraft or satellite passes through them. Ideally, experiments should be performed in a controlled environment, where plasma events can be deliberately and reliably created when wanted and probes placed precisely within the plasma. Unfortunately, often due to their size, probes used in outer space are unsuitable for use in high-density laboratory plasmas, and constructing probes that can be used in terrestrial plasmas is a considerable challenge. This dissertation presents the development, implementation, and experimental results of three micromachined probes capable of measuring voltage and electric field, ion energies, and changing magnetic fields (B-dot) in laboratory plasmas.

  4. The effects of calculator-based laboratories on standardized test scores

    NASA Astrophysics Data System (ADS)

    Stevens, Charlotte Bethany Rains

    Nationwide, the goal of providing a productive science and math education to our youth in today's educational institutions is centering itself around the technology being utilized in these classrooms. In this age of digital technology, educational software and calculator-based laboratories (CBL) have become significant devices in the teaching of science and math for many states across the United States. Among the technology, the Texas Instruments graphing calculator and Vernier Labpro interface, are among some of the calculator-based laboratories becoming increasingly popular among middle and high school science and math teachers in many school districts across this country. In Tennessee, however, it is reported that this type of technology is not regularly utilized at the student level in most high school science classrooms, especially in the area of Physical Science (Vernier, 2006). This research explored the effect of calculator based laboratory instruction on standardized test scores. The purpose of this study was to determine the effect of traditional teaching methods versus graphing calculator teaching methods on the state mandated End-of-Course (EOC) Physical Science exam based on ability, gender, and ethnicity. The sample included 187 total tenth and eleventh grade physical science students, 101 of which belonged to a control group and 87 of which belonged to the experimental group. Physical Science End-of-Course scores obtained from the Tennessee Department of Education during the spring of 2005 and the spring of 2006 were used to examine the hypotheses. The findings of this research study suggested the type of teaching method, traditional or calculator based, did not have an effect on standardized test scores. However, the students' ability level, as demonstrated on the End-of-Course test, had a significant effect on End-of-Course test scores. This study focused on a limited population of high school physical science students in the middle Tennessee

  5. Patient satisfaction with clinical laboratory services at Tikur Anbessa Specialized Hospital, Addis Ababa, Ethiopia

    PubMed Central

    Abera, Rodas Getachew; Abota, Boaz Arka; Legese, Melese Hailu; Negesso, Abebe Edao

    2017-01-01

    Background Monitoring patient satisfaction is an important and useful quality improvement tool for clinical laboratories in particular and health care organizations in general. Thus, this study aimed to assess patient satisfaction toward clinical laboratory services at Tikur Anbessa Specialized Hospital (TASH), Addis Ababa, Ethiopia. Methods A hospital-based cross-sectional study was conducted and a convenient sampling technique was applied to recruit study participants. A total of 210 patients who had received laboratory services were included. A self-administered predesigned, pretested, structured questionnaire was used, and data were collected through face-to-face interviews. A 5-point Likert scale with 1 and 5 indicating the lowest and highest levels of satisfaction, respectively, was used and their weighted average was used to categorize the satisfaction level of the patients. Chi square test was used (taking P≤0.05 as the statistically significant level) to find out if any association existed between the level of satisfaction and different attributes. Data were analyzed using SPSS version 20. Results The overall level of patient satisfaction toward clinical laboratory services in this study was 59.7% with a response rate of 210 (100%). The Likert scale results of patient satisfaction of the laboratory services revealed that the mean rating values ranged from 3.05 (±1.12) to 4.12 (±1.08) out of a possible 5. Among the different indicators, patients were highly satisfied with the cleanliness of facility (82%), maintenance of privacy and confidentiality (83.2%), and the cost of the laboratory service (86.5%), while they were dissatisfied with the location of the laboratory (56%), latrine accessibility and availability (58.4%), and latrine cleanness and comfort (63.8%). Conclusion The whole availability of requested tests, availability of place in blood drawing room to put personal things, and waiting time for specimen collection were found to have a

  6. The Pitfalls of Companion Diagnostics: Evaluation of Discordant EGFR Mutation Results from a Clinical Laboratory and a Central Laboratory.

    PubMed

    Turner, Scott A; Peterson, Jason D; Pettus, Jason R; de Abreu, Francine B; Amos, Christopher I; Dragnev, Konstantin H; Tsongalis, Gregory J

    2016-05-01

    Accurate identification of somatic mutations in formalin-fixed, paraffin-embedded tumor tissue is required for enrollment into clinical trials for many novel targeted therapeutics, including trials requiring EGFR mutation status in non-small-cell lung carcinomas. Central clinical trial laboratories contracted to perform this analysis typically rely on US Food and Drug Administration-approved targeted assays to identify these mutations. We present two cases in which central laboratories inaccurately reported EGFR mutation status because of improper identification and isolation of tumor material and failure to accurately report assay limitations, resulting in enrollment denial. Such cases highlight the need for increased awareness by clinical trials of the limitation of these US Food and Drug Administration-approved assays and the necessity for a mechanism to reevaluate discordant results by alternative laboratory-developed procedures, including clinical next-generation sequencing. Copyright © 2016 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  7. In-Flight Laboratory Analysis

    NASA Technical Reports Server (NTRS)

    Baumann, David; Perusek, Gail; Nelson, Emily; Krihak, Michael; Brown, Dan

    2012-01-01

    One-year study objectives align with HRP requirements. HRP requirements include measurement panels for research and medical operations - These measurement panels are distinctly different. Instrument requirements are defined - Power, volume and mass not quite a critical limitation as for medical operations (deep space exploration missions). One-year evaluation goals will lead HHC towards in-flight laboratory analysis capability.

  8. Effects of Intranasal Oxytocin Administration on Sexual Functions in Healthy Women: A Laboratory Paradigm.

    PubMed

    Kruger, Tillmann H C; Deiter, Frank; Zhang, Yuanyuan; Jung, Stefanie; Schippert, Cordula; Kahl, Kai G; Heinrichs, Markus; Schedlowski, Manfred; Hartmann, Uwe

    2018-06-01

    The neuropeptide oxytocin (OXT) has a variety of physiological functions in maternal behavior and attachment including sexual behavior. Based on animal research and our previous human studies, we set out to investigate intranasal administration of OXT and hypothesized that OXT should be able to modulate sexual function in women. In a double-blind, placebo-controlled, crossover laboratory setting, the acute effects of intranasal administered OXT (24 international units) on sexual drive, arousal, orgasm, and refractory aspects of sexual behavior were analyzed in 27 healthy females (mean age ± SD, 27.52 ± 8.04) together with physiological parameters using vaginal photoplethysmography. Oxytocin administration showed no effect on subjective sexual parameters (eg, postorgasmic tension; P = 0.051). Physiological parameters (vaginal photoplethysmography amplitude and vaginal blood volume) showed a response pattern towards sexual arousal but were not affected by OXT. Using a well-established laboratory paradigm, we did not find that intranasal OXT influences female sexual parameters. Also, sexual drive and other functions were not affected by OXT. These findings indicate that OXT is not able to significantly increase subjective and objective parameters of sexual function in a setting with high internal validity; however, this might be different in a more naturalistic setting.

  9. Laboratory challenges in the scaling up of HIV, TB, and malaria programs: The interaction of health and laboratory systems, clinical research, and service delivery.

    PubMed

    Birx, Deborah; de Souza, Mark; Nkengasong, John N

    2009-06-01

    Strengthening national health laboratory systems in resource-poor countries is critical to meeting the United Nations Millennium Development Goals. Despite strong commitment from the international community to fight major infectious diseases, weak laboratory infrastructure remains a huge rate-limiting step. Some major challenges facing laboratory systems in resource-poor settings include dilapidated infrastructure; lack of human capacity, laboratory policies, and strategic plans; and limited synergies between clinical and research laboratories. Together, these factors compromise the quality of test results and impact patient management. With increased funding, the target of laboratory strengthening efforts in resource-poor countries should be the integrating of laboratory services across major diseases to leverage resources with respect to physical infrastructure; types of assays; supply chain management of reagents and equipment; and maintenance of equipment.

  10. Emerging Technologies for the Clinical Microbiology Laboratory

    PubMed Central

    Buchan, Blake W.

    2014-01-01

    SUMMARY In this review we examine the literature related to emerging technologies that will help to reshape the clinical microbiology laboratory. These topics include nucleic acid amplification tests such as isothermal and point-of-care molecular diagnostics, multiplexed panels for syndromic diagnosis, digital PCR, next-generation sequencing, and automation of molecular tests. We also review matrix-assisted laser desorption ionization–time of flight (MALDI-TOF) and electrospray ionization (ESI) mass spectrometry methods and their role in identification of microorganisms. Lastly, we review the shift to liquid-based microbiology and the integration of partial and full laboratory automation that are beginning to impact the clinical microbiology laboratory. PMID:25278575

  11. Real-time optical laboratory solution of parabolic differential equations

    NASA Technical Reports Server (NTRS)

    Casasent, David; Jackson, James

    1988-01-01

    An optical laboratory matrix-vector processor is used to solve parabolic differential equations (the transient diffusion equation with two space variables and time) by an explicit algorithm. This includes optical matrix-vector nonbase-2 encoded laboratory data, the combination of nonbase-2 and frequency-multiplexed data on such processors, a high-accuracy optical laboratory solution of a partial differential equation, new data partitioning techniques, and a discussion of a multiprocessor optical matrix-vector architecture.

  12. Evaluation of clinical and laboratory findings in pediatric post-streptococcal glomerulonephritis.

    PubMed

    Kılıc, Beltinge Demircioglu; Kara, Mehtap Akbalık; Buyukcelik, Mithat; Balat, Ayse

    2018-05-05

    Acute post-streptococcal glomerulonephritis (APSGN) is the most common postinfectious glomerulonephritis in childhood. In this study, we aimed to determine the possible risk factor(s), responsible for decreased glomerular filtration rate (GFR) in APSGN. The data of patients followed up with the diagnosis of APSGN in the Pediatric Nephrology Clinic of Gaziantep University Hospital between October 2014 and October 2016 were retrospectively evaluated. Total number of subjects was 75 (Male/Female:42/33) with the mean age of 8.20±3.25 years. Most common presentations were edema (86.7%), macroscopic hematuria (82.7%) and hypertension (73.3%, n=55). In laboratory examination, 28 children (37.3%) had hypoalbuminemia, 58 (77.3%) had proteinuria, 20 (26.7%) had increased C reactive protein (CRP), while 74 (98.7%) and 12 (16%) of them had decreased C3 and C4 levels, respectively. The number of children with GFR value <90 ml/min/1.73/m2 was 22 (29.3%). The risk of decreased GFR was significantly higher in patients with increased CRP (p:0.001,OR:3.58), hypoalbuminemia (p:0.006,OR:4.83), and decreased C4 level (p:0.010,OR:11.53). Additionally, white blood cell (WBC), neutrophil count, and neutrophil-lymphocyte ratio (NLR) were significantly higher (p:0.02, p:0.006, p:0.004, respectively) in patients with low GFR. Although the prognosis of APSGN in children is good, severe systemic complications and renal failure may develop during the follow-up period. We suggest that decreased C4 level, presence of hypoalbuminemia, increased inflammatory markers (WBC, CRP, neutrophil count and NLR) might be possible risk factors for severity of renal involvement. Especially decreased C4 level may be a risk factor for decreased GFR in those children. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  13. Pharyngitis of infectious mononucleosis: computed tomography findings.

    PubMed

    Kutuya, Naoki; Kurosaki, Yoshihisa; Suzuki, Kazuhiro; Takata, Koremochi; Shiraihshi, Akihiko

    2008-05-01

    Two women presented with sore throat and fever. Their symptoms were not alleviated by antibiotics. Cervical computed tomography (CT) with contrast enhancement demonstrated enlargement of predominant posterior cervical lymph nodes and streaky heterogeneous tonsils with interspersed low attenuation. They were diagnosed as having infectious mononucleosis by their laboratory data. Thus, when radiologists encounter these CT findings of pharyngitis that is not alleviated by antibiotic therapy, infectious mononucleosis should be considered in the differential diagnosis.

  14. Laboratory Animal Facilities. Laboratory Design Notes.

    ERIC Educational Resources Information Center

    Jonas, Albert M.

    1965-01-01

    Design of laboratory animal facilities must be functional. Accordingly, the designer should be aware of the complex nature of animal research and specifically the type of animal research which will be conducted in a new facility. The building of animal-care facilities in research institutions requires special knowledge in laboratory animal…

  15. Assessment of Tutoring Laboratories in a Learning Assistance Center

    ERIC Educational Resources Information Center

    Fullmer, Patricia

    2012-01-01

    The Learning Resource Center at Lincoln University, Pennsylvania, provides tutoring laboratories that are required for developmental reading, writing, and math courses. This article reviews the processes used to plan and determine the effectiveness of the tutoring laboratories, including logic models, student learning outcomes, and the results of…

  16. Basic Laboratory Skills. Training Module 5.300.2.77.

    ERIC Educational Resources Information Center

    Kirkwood Community Coll., Cedar Rapids, IA.

    This document is an instructional module package prepared in objective form for use by an instructor familiar with the basic chemical and microbiological laboratory equipment and procedures used in water and wastewater treatment plant laboratories. Included are objectives, instructor guides, student handouts and transparency masters. This module…

  17. Simple non-laboratory- and laboratory-based risk assessment algorithms and nomogram for detecting undiagnosed diabetes mellitus.

    PubMed

    Wong, Carlos K H; Siu, Shing-Chung; Wan, Eric Y F; Jiao, Fang-Fang; Yu, Esther Y T; Fung, Colman S C; Wong, Ka-Wai; Leung, Angela Y M; Lam, Cindy L K

    2016-05-01

    The aim of the present study was to develop a simple nomogram that can be used to predict the risk of diabetes mellitus (DM) in the asymptomatic non-diabetic subjects based on non-laboratory- and laboratory-based risk algorithms. Anthropometric data, plasma fasting glucose, full lipid profile, exercise habits, and family history of DM were collected from Chinese non-diabetic subjects aged 18-70 years. Logistic regression analysis was performed on a random sample of 2518 subjects to construct non-laboratory- and laboratory-based risk assessment algorithms for detection of undiagnosed DM; both algorithms were validated on data of the remaining sample (n = 839). The Hosmer-Lemeshow test and area under the receiver operating characteristic (ROC) curve (AUC) were used to assess the calibration and discrimination of the DM risk algorithms. Of 3357 subjects recruited, 271 (8.1%) had undiagnosed DM defined by fasting glucose ≥7.0 mmol/L or 2-h post-load plasma glucose ≥11.1 mmol/L after an oral glucose tolerance test. The non-laboratory-based risk algorithm, with scores ranging from 0 to 33, included age, body mass index, family history of DM, regular exercise, and uncontrolled blood pressure; the laboratory-based risk algorithm, with scores ranging from 0 to 37, added triglyceride level to the risk factors. Both algorithms demonstrated acceptable calibration (Hosmer-Lemeshow test: P = 0.229 and P = 0.483) and discrimination (AUC 0.709 and 0.711) for detection of undiagnosed DM. A simple-to-use nomogram for detecting undiagnosed DM has been developed using validated non-laboratory-based and laboratory-based risk algorithms. © 2015 Ruijin Hospital, Shanghai Jiaotong University School of Medicine and Wiley Publishing Asia Pty Ltd.

  18. PBF Control Building auxiliary features, including fire hose house and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PBF Control Building auxiliary features, including fire hose house and sewage system. Ebasco Services 1205 PER/PER-A-4. INEEL undex no. 760-0619-00-205-123024 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID

  19. 38. SECTIONS OF ACCESS CORRIDOR, INCLUDES SECTION SHOWING ARRANGEMENT OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    38. SECTIONS OF ACCESS CORRIDOR, INCLUDES SECTION SHOWING ARRANGEMENT OF NAVY GUN BARRELS. INEEL DRAWING NUMBER 200-0633-00-287-106454. FLUOR NUMBER 5775-CPP-633-P-59. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID

  20. Miniaturization and globalization of clinical laboratory activities.

    PubMed

    Melo, Murilo R; Clark, Samantha; Barrio, Daniel

    2011-04-01

    Clinical laboratories provide an invaluable service to millions of people around the world in the form of quality diagnostic care. Within the clinical laboratory industry the impetus for change has come from technological development (miniaturization, nanotechnology, and their collective effect on point-of-care testing; POCT) and the increasingly global nature of laboratory services. Potential technological gains in POCT include: the development of bio-sensors, microarrays, genetics and proteomics testing, and enhanced web connectivity. In globalization, prospective opportunities lie in: medical tourism, the migration of healthcare workers, cross-border delivery of testing, and the establishment of accredited laboratories in previously unexplored markets. Accompanying these impressive opportunities are equally imposing challenges. Difficulty transitioning from research to clinical use, poor infrastructure in developing countries, cultural differences and national barriers to global trade are only a few examples. Dealing with the issues presented by globalization and the impact of developing technology on POCT, and on the clinical laboratory services industry in general, will be a daunting task. Despite such concerns, with appropriate countermeasures it will be possible to address the challenges posed. Future laboratory success will be largely dependent on one's ability to adapt in this perpetually shifting landscape.

  1. Developing a lean culture in the laboratory.

    PubMed

    Napoles, Leyda; Quintana, Maria

    2006-07-25

    The Director of Pathology at Jackson Memorial Hospital was interested in improving the operational efficiencies of the department in order to enhance the department's level of service in conjunction with the expansion of the overall health system. The decision was made to implement proven Lean practices in the laboratory under the direction of a major consulting firm. This article details the scope of the initial project as well as the operating principles of Lean manufacturing practices as applied to the clinical laboratory. The goals of the project were to improve turnaround times of laboratory results, reduce inventory and supply costs, improve staff productivity, maximize workflow, and eliminate waste. Extensive data gathering and analysis guided the work process by highlighting the areas of highest opportunity. This systematic approach resulted in recommendations for the workflow and physical layout of the laboratory. It also included the introduction of "standard workflow" and "visual controls" as critical items that streamlined operational efficiencies. The authors provide actual photographs and schematics of the reorganization and improvements to the physical layout of the laboratory. In conclusion, this project resulted in decreased turnaround times and increased productivity, as well as significant savings in the overall laboratory operations.

  2. Interpreting the Laboratory Reports for Vit D.

    PubMed

    Sarmah, Devajit; Sharma, Booloo

    2014-09-01

    Importance for Vit D estimation has increased in the recent years due to its link to various diseases. Measurements of Vit D by different diagnostic laboratories is however not uniform. There is variation pertaining to assay methodology and also variation in the measurement of different metabolites of Vit D. There are also various confounders which influence Vit D assays and which in most instances are overlooked. Also a matter of concern regarding Vit D assays is the lack of assay standardisation. These factors contribute to the variation in the reports generated by the diagnostic laboratories. Therefore interpretation of Vit D reports needs proper understanding of these interfering factors and further reports need to be correlated substantially with the clinical findings.

  3. Outreach Plans for Storm Peak Laboratory

    NASA Astrophysics Data System (ADS)

    Hallar, A. G.; McCubbin, I. B.

    2006-12-01

    The Desert Research Institute (DRI) operates a high elevation facility, Storm Peak Laboratory (SPL), located on the west summit of Mt. Werner in the Park Range near Steamboat Springs, Colorado at an elevation 10,500 ft. SPL provides an ideal location for long-term research on the interactions of atmospheric aerosol and gas- phase chemistry with cloud and natural radiation environments. SPL includes an office-type laboratory room for computer and instrumentation setup with outside air ports and cable access to the roof deck, a full kitchen and two bunk rooms with sleeping space for nine persons. We plan to create a unique summer undergraduate education experiences for students of diversity at Storm Peak Laboratory. As stressed by the College Pathways to Science Education Standards [Siebert and McIntosh, 2001], to support changes in K-12 science education transformations must first be made at the college level, including inquiry-oriented opportunities to engage in meaningful research. These workshops will be designed to allow students to experience the excitement of science, increasing their likelihood of pursing careers within the fields of scientific education or research.

  4. Total laboratory automation: Do stat tests still matter?

    PubMed

    Dolci, Alberto; Giavarina, Davide; Pasqualetti, Sara; Szőke, Dominika; Panteghini, Mauro

    2017-07-01

    During the past decades the healthcare systems have rapidly changed and today hospital care is primarily advocated for critical patients and acute treatments, for which laboratory test results are crucial and need to be always reported in predictably short turnaround time (TAT). Laboratories in the hospital setting can face this challenge by changing their organization from a compartmentalized laboratory department toward a decision making-based laboratory department. This requires the implementation of a core laboratory, that exploits total laboratory automation (TLA) using technological innovation in analytical platforms, track systems and information technology, including middleware, and a number of satellite specialized laboratory sections cooperating with care teams for specific medical conditions. In this laboratory department model, the short TAT for all first-line tests performed by TLA in the core laboratory represents the key paradigm, where no more stat testing is required because all samples are handled in real-time and (auto)validated results dispatched in a time that fulfills clinical needs. To optimally reach this goal, laboratories should be actively involved in managing all the steps covering the total examination process, speeding up also extra-laboratory phases, such sample delivery. Furthermore, to warrant effectiveness and not only efficiency, all the processes, e.g. specimen integrity check, should be managed by middleware through a predefined set of rules defined in light of the clinical governance. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  5. State of laboratory manual instruction in California community college introductory (non-majors) biology laboratory instruction

    NASA Astrophysics Data System (ADS)

    Priest, Michelle

    utilize the current faculty research expertise and knowledge. Unfortunately, laboratory manual authors had no real learning framework in the development of the manual. Based on the LAI, most manuals focused on the lowest levels of inquiry based instruction. Most manuals focused exercises on cell and molecular topics. The manuals had little student exploration, creation or design in the laboratory exercise and no option for repeating the exercise. There was a clear desire of faculty and authors to improve the laboratory experience and manual. Authors and faculty wished to include more inquiry and utilize the best of Student Learning Outcome (SLO) methodologies. Authors and the laboratory manuals have a major disconnect in that authors have clear desires inquiry based learning for the manual but do not effectively implement the inquiry based learning for various reasons. The manuals themselves, laboratory manuals themselves are not robust inquiry based learning models to maximize student learning. Authors and faculty are disconnected in that authors know what they want their manuals to do...but do not effectively communicate that to faculty. Finally, schools are in a "wait and see" approach as to when to integrate the latest learning theory mandated by the Chancellors Office -- Student Learning Outcomes.

  6. Effects of Water Bottle Materials and Filtration on Bisphenol A Content in Laboratory Animal Drinking Water.

    PubMed

    Honeycutt, Jennifer A; Nguyen, Jenny Q T; Kentner, Amanda C; Brenhouse, Heather C

    2017-05-01

    Bisphenol A (BPA) is widely used in the polycarbonate plastics and epoxy resins that are found in laboratory animal husbandry materials including cages and water bottles. Concerns about BPA exposure in humans has led to investigations that suggest physiologic health risks including disruptions to the endocrine system and CNS. However, the extent of exposure of laboratory animals to BPA in drinking water is unclear. In the first study, we compared the amount of BPA contamination in water stored in plastic bottles used in research settings with that in glass bottles. The amount of BPA that leached into water was measured across several time points ranging from 24 to 96 h by using a BPA ELISA assay. The results showed that considerable amounts of BPA (approximately 0.15 μg/L) leached from polycarbonate bottles within the first 24 h of storage. In the second study, BPA levels were measured directly from water taken from filtered compared with unfiltered taps. We observed significantly higher BPA levels in water from unfiltered taps (approximately 0.40 μg/L) compared with taps with filtration systems (approximately 0.04 μg/L). Taken together, our findings indicate that the use of different types of water bottles and water sources, combined with the use of different laboratory products (food, caging systems) between laboratories, likely contribute to decreased rigor and reproducibility in research. We suggest that researchers consider reporting the types of water bottles used and that animal care facilities educate staff regarding the importance of flushing nonfiltered water taps when filling animal water bottles.

  7. Effects of Water Bottle Materials and Filtration on Bisphenol A Content in Laboratory Animal Drinking Water

    PubMed Central

    Honeycutt, Jennifer A; Nguyen, Jenny Q T; Kentner, Amanda C; Brenhouse, Heather C

    2017-01-01

    Bisphenol A (BPA) is widely used in the polycarbonate plastics and epoxy resins that are found in laboratory animal husbandry materials including cages and water bottles. Concerns about BPA exposure in humans has led to investigations that suggest physiologic health risks including disruptions to the endocrine system and CNS. However, the extent of exposure of laboratory animals to BPA in drinking water is unclear. In the first study, we compared the amount of BPA contamination in water stored in plastic bottles used in research settings with that in glass bottles. The amount of BPA that leached into water was measured across several time points ranging from 24 to 96 h by using a BPA ELISA assay. The results showed that considerable amounts of BPA (approximately 0.15 μg/L) leached from polycarbonate bottles within the first 24 h of storage. In the second study, BPA levels were measured directly from water taken from filtered compared with unfiltered taps. We observed significantly higher BPA levels in water from unfiltered taps (approximately 0.40 μg/L) compared with taps with filtration systems (approximately 0.04 μg/L). Taken together, our findings indicate that the use of different types of water bottles and water sources, combined with the use of different laboratory products (food, caging systems) between laboratories, likely contribute to decreased rigor and reproducibility in research. We suggest that researchers consider reporting the types of water bottles used and that animal care facilities educate staff regarding the importance of flushing nonfiltered water taps when filling animal water bottles. PMID:28535862

  8. Developments of Spent Nuclear Fuel Pyroprocessing Technology at Idaho National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michael F. Simpson

    This paper summarizes research in used fuel pyroprocessing that has been published by Idaho National Laboratory over the last decade. It includes work done both on treatment of Experimental Breeder Reactor-II and development of advanced technology for potential scale-up and commercialization. Collaborations with universities and other laboratories is included in the cited work.

  9. How do laboratory technicians perceive their role in the tuberculosis diagnostic process? A cross-sectional study among laboratory technicians in health centers of Central Java Province, Indonesia.

    PubMed

    Widjanarko, Bagoes; Widyastari, Dyah Anantalia; Martini, Martini; Ginandjar, Praba

    2016-01-01

    Detection of acid-fast bacilli in respiratory specimens serves as an initial pulmonary tuberculosis (TB) diagnosis. Laboratories are the essential and fundamental part of all health systems. This study aimed to describe how laboratory technicians perceived their own self and work. This included perceived self-efficacy, perceived role, perceived equipment availability, perceived procedures, perceived reward and job, and perceived benefit of health education, as well as level of knowledge and attitudes related to work performance of laboratory technicians. This was a cross-sectional quantitative study involving 120 laboratory technicians conducted in Central Java. Interviews and observation were conducted to measure performance and work-related variables. Among 120 laboratory technicians, 43.3% showed fairly good performance. They complied with 50%-75% of all procedures, including sputum collection, laboratory tools utilization, sputum smearing, staining, smear examination, grading of results, and universal precaution practice. Perceived role, perceived self-efficacy, and knowledge of laboratory procedures were significantly correlated to performance, besides education and years of working as a laboratory technician. Perceived equipment availability was also significantly correlated to performance after the education variable was controlled. Most of the laboratory technicians believed that they have an important role in TB patients' treatment and should display proper self-efficacy in performing laboratory activities. The result may serve as a basic consideration to develop a policy for enhancing motivation of laboratory technicians in order to improve the TB control program.

  10. How do laboratory technicians perceive their role in the tuberculosis diagnostic process? A cross-sectional study among laboratory technicians in health centers of Central Java Province, Indonesia

    PubMed Central

    Widjanarko, Bagoes; Widyastari, Dyah Anantalia; Martini, Martini; Ginandjar, Praba

    2016-01-01

    Purpose Detection of acid-fast bacilli in respiratory specimens serves as an initial pulmonary tuberculosis (TB) diagnosis. Laboratories are the essential and fundamental part of all health systems. This study aimed to describe how laboratory technicians perceived their own self and work. This included perceived self-efficacy, perceived role, perceived equipment availability, perceived procedures, perceived reward and job, and perceived benefit of health education, as well as level of knowledge and attitudes related to work performance of laboratory technicians. Methods This was a cross-sectional quantitative study involving 120 laboratory technicians conducted in Central Java. Interviews and observation were conducted to measure performance and work-related variables. Results Among 120 laboratory technicians, 43.3% showed fairly good performance. They complied with 50%–75% of all procedures, including sputum collection, laboratory tools utilization, sputum smearing, staining, smear examination, grading of results, and universal precaution practice. Perceived role, perceived self-efficacy, and knowledge of laboratory procedures were significantly correlated to performance, besides education and years of working as a laboratory technician. Perceived equipment availability was also significantly correlated to performance after the education variable was controlled. Conclusion Most of the laboratory technicians believed that they have an important role in TB patients’ treatment and should display proper self-efficacy in performing laboratory activities. The result may serve as a basic consideration to develop a policy for enhancing motivation of laboratory technicians in order to improve the TB control program. PMID:27660502

  11. Understanding the dynamics and energetics of magnetic reconnection in a laboratory plasma: Review of recent progress on selected fronts

    DOE PAGES

    Yamada, Masaaki; Yoo, Jongsoo; Myers, Clayton E.

    2016-05-11

    Here, magnetic reconnection is a fundamental process at work in laboratory, space, and astrophysical plasmas, in which magnetic field lines change their topology and convert magnetic energy to plasma particles by acceleration and heating. One of the most important problems in reconnection research has been to understand why reconnection occurs so much faster than predicted by magnetohydrodynamics theory. Following the recent pedagogical review of this subject [Yamada et al., Rev. Mod. Phys. 82, 603 (2010)], this paper presents a review of more recent discoveries and findings in the research of fast magnetic reconnection in laboratory, space, and astrophysical plasmas. Inmore » spite of the huge difference in physical scales, we find remarkable commonality between the characteristics of the magnetic reconnection in laboratory and space plasmas. In this paper, we will focus especially on the energy flow, a key feature of the reconnection process. In particular, the experimental results on the energy conversion and partitioning in a laboratory reconnection layer [Yamada et al., Nat. Commun. 5, 4474 (2014)] are discussed and compared with quantitative estimates based on two-fluid analysis. In the Magnetic ReconnectionExperiment, we find that energy deposition to electrons is localized near the X-point and is mostly from the electric field component perpendicular to the magnetic field. The mechanisms of ion acceleration and heating are also identified, and a systematic and quantitative study on the inventory of converted energy within a reconnection layer with a well-defined but variable boundary. The measured energy partition in a reconnection region of similar effective size (L ≈ 3 ion skin depths) of the Earth's magneto-tail [Eastwood et al., Phys. Rev. Lett. 110, 225001 (2013)] is notably consistent with our laboratory results. Finally, to study the global aspects of magnetic reconnection, we have carried out a laboratory experiment on the stability criteria for

  12. A far-infrared spatial/spectral Fourier interferometry laboratory-based testbed instrument

    NASA Astrophysics Data System (ADS)

    Spencer, Locke D.; Naylor, David A.; Scott, Jeremy P.; Weiler, Vince F.; MacCrimmon, Roderick K.; Sitwell, Geoffrey R. H.; Ade, Peter A. R.

    2016-07-01

    We describe the current status, including preliminary design, characterization efforts, and recent progress, in the development of a spatial/spectral double Fourier laboratory-based interferometer testbed instrument within the Astronomical Instrumentation Group (AIG) laboratories at the University of Lethbridge, Canada (UL). Supported by CRC, CFI, and NSERC grants, this instrument development will provide laboratory demonstration of spatial-spectral interferometry with a concentration of furthering progress in areas including the development of spatial/spectral interferometry observation, data processing, characterization, and analysis techniques in the Far-Infrared (FIR) region of the electromagnetic spectrum.

  13. Current safety practices in nano-research laboratories in China.

    PubMed

    Zhang, Can; Zhang, Jing; Wang, Guoyu

    2014-06-01

    China has become a key player in the global nanotechnology field, however, no surveys have specifically examined safety practices in the Chinese nano-laboratories in depth. This study reports results of a survey of 300 professionals who work in research laboratories that handle nanomaterials in China. We recruited participants at three major nano-research laboratories (which carry out research in diverse fields such as chemistry, material science, and biology) and the nano-chemistry session of the national meeting of the Chinese Chemical Society. Results show that almost all nano-research laboratories surveyed had general safety regulations, whereas less than one third of respondents reported having nanospecific safety rules. General safety measures were in place in most surveyed nano-research laboratories, while nanospecific protective measures existed or were implemented less frequently. Several factors reported from the scientific literature including nanotoxicology knowledge gaps, technical limitations on estimating nano-exposure, and the lack of nano-occupational safety legislation may contribute to the current state of affairs. With these factors in mind and embracing the precautionary principle, we suggest strengthening or providing nanosafety training (including raising risk awareness) and establishing nanosafety guidelines in China, to better protect personnel in the nano-workplace.

  14. Guide for Science Laboratory Safety.

    ERIC Educational Resources Information Center

    McDermott, John J.

    General and specific safety procedures and recommendations for secondary school science laboratories are provided in this guide. Areas of concern include: (1) chemicals (storage, disposal, toxicity, unstable and incompatible chemicals); (2) microorganisms; (3) plants; (4) animals; (5) electricity; (6) lasers; (7) rockets; (8) eye safety and…

  15. Multicellular microorganisms: laboratory versus nature.

    PubMed

    Palková, Zdena

    2004-05-01

    Our present in-depth knowledge of the physiology and regulatory mechanisms of microorganisms has arisen from our ability to remove them from their natural, complex ecosystems into pure liquid cultures. These cultures are grown under optimized laboratory conditions and allow us to study microorganisms as individuals. However, microorganisms naturally grow in conditions that are far from optimal, which causes them to become organized into multicellular communities that are better protected against the harmful environment. Moreover, this multicellular existence allows individual cells to differentiate and acquire specific properties, such as forming resistant spores, which benefit the whole population. The relocation of natural microorganisms to the laboratory can result in their adaptation to these favourable conditions, which is accompanied by complex changes that include the repression of some protective mechanisms that are essential in nature. Laboratory microorganisms that have been cultured for long periods under optimized conditions might therefore differ markedly from those that exist in natural ecosystems.

  16. Exposure to hazardous substances in a standard molecular biology laboratory environment: evaluation of exposures in IARC laboratories.

    PubMed

    Chapot, Brigitte; Secretan, Béatrice; Robert, Annie; Hainaut, Pierre

    2009-07-01

    Working in a molecular biology laboratory environment implies regular exposure to a wide range of hazardous substances. Several recent studies have shown that laboratory workers may have an elevated risk of certain cancers. Data on the nature and frequency of exposures in such settings are scanty. The frequency of use of 163 agents by staff working in molecular biology laboratories was evaluated over a period of 4 years by self-administered questionnaire. Of the agents listed, ethanol was used by the largest proportion of staff (70%), followed by ethidium bromide (55%). Individual patterns of use showed three patterns, namely (i) frequent use of a narrow range of products, (ii) occasional use of a wide range of products, and (iii) frequent and occasional use of an intermediate range of products. Among known or suspected carcinogens (International Agency for Research on Cancer Group 1 and 2A, respectively), those most frequently used included formaldehyde (17%), oncogenic viruses (4%), and acrylamide (32%). The type of exposure encountered in research laboratories is extremely diverse. Few carcinogenic agents are used frequently but many laboratory workers may be exposed occasionally to known human carcinogens. In addition, many of the chemicals handled by staff represent a health hazard. The results enabled the staff physician to develop an individual approach to medical surveillance and to draw a personal history of occupational exposures for laboratory staff.

  17. Tested Studies for Laboratory Teaching. Proceedings of the Workshop/Conference of the Association for Biology Laboratory Education (ABLE) (12th, Springfield, Missouri, June 4-8, 1990). Volume 12.

    ERIC Educational Resources Information Center

    Goldman, Corey A., Ed.

    The focus of the Association for Biology Laboratory Education (ABLE) is to improve the undergraduate biology laboratory experience by promoting the development and dissemination of interesting, innovative, and reliable laboratory exercises. This proceedings volume includes 13 papers: "Non-Radioactive DNA Hybridization Experiments for the…

  18. Extra-analytical quality indicators and laboratory performances.

    PubMed

    Sciacovelli, Laura; Aita, Ada; Plebani, Mario

    2017-07-01

    In the last few years much progress has been made in raising the awareness of laboratory medicine professionals about the effectiveness of quality indicators (QIs) in monitoring, and improving upon, performances in the extra-analytical phases of the Total Testing Process (TTP). An effective system for management of QIs includes the implementation of an internal assessment system and participation in inter-laboratory comparison. A well-designed internal assessment system allows the identification of critical activities and their systematic monitoring. Active participation in inter-laboratory comparison provides information on the performance level of one laboratory with respect to that of other participating laboratories. In order to guarantee the use of appropriate QIs and facilitate their implementation, many laboratories have adopted the Model of Quality Indicators (MQI) proposed by Working Group "Laboratory Errors and Patient Safety" (WG-LEPS) of IFCC, since 2008, which is the result of international consensus and continuous experimentation, and updating to meet new, constantly emerging needs. Data from participating laboratories are collected monthly and reports describing the statistical results and evaluating laboratory data, utilizing the Six Sigma metric, issued regularly. Although the results demonstrate that the processes need to be improved upon, overall the comparison with data collected in 2014 shows a general stability of quality levels and that an improvement has been achieved over time for some activities. The continuous monitoring of QI data allows identification all possible improvements, thus highlighting the value of participation in the inter-laboratory program proposed by WG-LEPS. The active participation of numerous laboratories will guarantee an ever more significant State-of-the-Art, promote the reduction of errors and improve quality of the TTP, thus guaranteeing patient safety. Copyright © 2017. Published by Elsevier Inc.

  19. Laboratory-based maximum slip rates in earthquake rupture zones and radiated energy

    USGS Publications Warehouse

    McGarr, A.; Fletcher, Joe B.; Boettcher, M.; Beeler, N.; Boatwright, J.

    2010-01-01

    Laboratory stick-slip friction experiments indicate that peak slip rates increase with the stresses loading the fault to cause rupture. If this applies also to earthquake fault zones, then the analysis of rupture processes is simplified inasmuch as the slip rates depend only on the local yield stress and are independent of factors specific to a particular event, including the distribution of slip in space and time. We test this hypothesis by first using it to develop an expression for radiated energy that depends primarily on the seismic moment and the maximum slip rate. From laboratory results, the maximum slip rate for any crustal earthquake, as well as various stress parameters including the yield stress, can be determined based on its seismic moment and the maximum slip within its rupture zone. After finding that our new equation for radiated energy works well for laboratory stick-slip friction experiments, we used it to estimate radiated energies for five earthquakes with magnitudes near 2 that were induced in a deep gold mine, an M 2.1 repeating earthquake near the San Andreas Fault Observatory at Depth (SAFOD) site and seven major earthquakes in California and found good agreement with energies estimated independently from spectra of local and regional ground-motion data. Estimates of yield stress for the earthquakes in our study range from 12 MPa to 122 MPa with a median of 64 MPa. The lowest value was estimated for the 2004 M 6 Parkfield, California, earthquake whereas the nearby M 2.1 repeating earthquake, as recorded in the SAFOD pilot hole, showed a more typical yield stress of 64 MPa.

  20. Errors in clinical laboratories or errors in laboratory medicine?

    PubMed

    Plebani, Mario

    2006-01-01

    Laboratory testing is a highly complex process and, although laboratory services are relatively safe, they are not as safe as they could or should be. Clinical laboratories have long focused their attention on quality control methods and quality assessment programs dealing with analytical aspects of testing. However, a growing body of evidence accumulated in recent decades demonstrates that quality in clinical laboratories cannot be assured by merely focusing on purely analytical aspects. The more recent surveys on errors in laboratory medicine conclude that in the delivery of laboratory testing, mistakes occur more frequently before (pre-analytical) and after (post-analytical) the test has been performed. Most errors are due to pre-analytical factors (46-68.2% of total errors), while a high error rate (18.5-47% of total errors) has also been found in the post-analytical phase. Errors due to analytical problems have been significantly reduced over time, but there is evidence that, particularly for immunoassays, interference may have a serious impact on patients. A description of the most frequent and risky pre-, intra- and post-analytical errors and advice on practical steps for measuring and reducing the risk of errors is therefore given in the present paper. Many mistakes in the Total Testing Process are called "laboratory errors", although these may be due to poor communication, action taken by others involved in the testing process (e.g., physicians, nurses and phlebotomists), or poorly designed processes, all of which are beyond the laboratory's control. Likewise, there is evidence that laboratory information is only partially utilized. A recent document from the International Organization for Standardization (ISO) recommends a new, broader definition of the term "laboratory error" and a classification of errors according to different criteria. In a modern approach to total quality, centered on patients' needs and satisfaction, the risk of errors and mistakes

  1. Health and safety in clinical laboratories in developing countries: safety considerations.

    PubMed

    Ejilemele, A A; Ojule, A C

    2004-01-01

    Clinical laboratories are potentially hazardous work areas. Health and safety in clinical laboratories is becoming an increasingly important subject as a result of the emergence of highly infectious diseases such as hepatitis and HIV. This is even more so in developing countries where health and safety have traditionally been regarded as low priority issues, considering the more important health problems confronting the health authorities in these countries. We conducted a literature search using the medical subheadings titles on the INTERNET over a period of twenty years and summarized our findings. This article identifies hazards in the laboratories and highlights measures to make the laboratory a safer work place. It also emphasizes the mandatory obligations of employers and employees towards the attainment of acceptable safety standards in clinical laboratories in Third World countries in the face of the current HIV/AIDS epidemic in many of these developing countries especially in the sub-Saharan Africa while accommodating the increasing work load in these laboratories. Both the employer and the employee have major roles to play in the maintenance of a safe working environment. This can be achieved if measures discussed are incorporated into everyday laboratory practice.

  2. Publications of the Jet Propulsion Laboratory 1983

    NASA Technical Reports Server (NTRS)

    1984-01-01

    The Jet propulsion Laboratory (JPL) bibliography describes and indexes by primary author the externally distributed technical reporting, released during calendar year 1983, that resulted from scientific and engineering work performed, or managed, by the Jet Propulsion Laboratory. Three classes of publications are included. JPL Publication (81-,82-,83-series, etc.), in which the information is complete for a specific accomplishment, articles published in the open literature, and articles from the quarterly telecommunications and Data Acquisition (TDA) Progress Report (42-series) are included. Each collection of articles in this class of publication presents a periodic survey of current accomplishments by the Deep Space Network as well as other developments in Earth-based radio technology.

  3. Phlebotomy, a bridge between laboratory and patient

    PubMed Central

    Ialongo, Cristiano; Bernardini, Sergio

    2016-01-01

    The evidence-based paradigm has changed and evolved medical practice. Phlebotomy, which dates back to the age of ancient Greece, has gained experience through the evolution of medicine becoming a fundamental diagnostic tool. Nowadays it connects the patient with the clinical laboratory dimension building up a bridge. However, more often there is a gap between laboratory and phlebotomist that causes misunderstandings and burdens on patient safety. Therefore, the scope of this review is delivering a view of modern phlebotomy to “bridge” patient and laboratory. In this regard the paper describes devices, tools and procedures in the light of the most recent scientific findings, also discussing their impact on both quality of blood testing and patient safety. It also addresses the issues concerning medical aspect of venipuncture, like the practical approach to the superficial veins anatomy, as well as the management of the patient’s compliance with the blood draw. Thereby, the clinical, technical and practical issues are treated with the same relevance throughout the entire paper. PMID:26981016

  4. Students' Knowledge Construction in Small Groups in the Seventh Grade Biology Laboratory: Verbal Communication and Physical Engagement.

    ERIC Educational Resources Information Center

    She, Hsiao-Ching

    1999-01-01

    Reports on a study of seventh-grade students' interactions in small groups during a biology laboratory activity. Finds that girls have the potential to perform equally as well as do boys in the science laboratory and that both individual and gender differences contribute to students' differential verbal communication and laboratory engagement.…

  5. Secondary standards laboratories for ionizing radiation calibrations: The national laboratory interests

    NASA Astrophysics Data System (ADS)

    Roberson, P. I.; Campbell, G. W.

    1984-11-01

    The national laboratories are probable candidates to serve as secondary standards laboratories for the federal sector. Representatives of the major Department of Energy laboratories were polled concerning attitudes toward a secondary laboratory structure. Generally, the need for secondary laboratories was recognized and the development of such a program was encouraged. The secondary laboratories should be reviewed and inspected by the National Bureau of Standards. They should offer all of the essential, and preferably additional, calibration services in the field of radiological health protection. The selection of secondary laboratories should be based on economic and geographic criteria and/or be voluntary.

  6. Roles of laboratories and laboratory systems in effective tuberculosis programmes.

    PubMed

    Ridderhof, John C; van Deun, Armand; Kam, Kai Man; Narayanan, P R; Aziz, Mohamed Abdul

    2007-05-01

    Laboratories and laboratory networks are a fundamental component of tuberculosis (TB) control, providing testing for diagnosis, surveillance and treatment monitoring at every level of the health-care system. New initiatives and resources to strengthen laboratory capacity and implement rapid and new diagnostic tests for TB will require recognition that laboratories are systems that require quality standards, appropriate human resources, and attention to safety in addition to supplies and equipment. To prepare the laboratory networks for new diagnostics and expanded capacity, we need to focus efforts on strengthening quality management systems (QMS) through additional resources for external quality assessment programmes for microscopy, culture, drug susceptibility testing (DST) and molecular diagnostics. QMS should also promote development of accreditation programmes to ensure adherence to standards to improve both the quality and credibility of the laboratory system within TB programmes. Corresponding attention must be given to addressing human resources at every level of the laboratory, with special consideration being given to new programmes for laboratory management and leadership skills. Strengthening laboratory networks will also involve setting up partnerships between TB programmes and those seeking to control other diseases in order to pool resources and to promote advocacy for quality standards, to develop strategies to integrate laboratories functions and to extend control programme activities to the private sector. Improving the laboratory system will assure that increased resources, in the form of supplies, equipment and facilities, will be invested in networks that are capable of providing effective testing to meet the goals of the Global Plan to Stop TB.

  7. Validating Laboratory Results in Electronic Health Records

    PubMed Central

    Perrotta, Peter L.; Karcher, Donald S.

    2017-01-01

    Context Laboratories must ensure that the test results and pathology reports they transmit to a patient’s electronic health record (EHR) are accurate, complete, and presented in a useable format. Objective To determine the accuracy, completeness, and formatting of laboratory test results and pathology reports transmitted from the laboratory to the EHR. Design Participants from 45 institutions retrospectively reviewed results from 16 different laboratory tests, including clinical and anatomic pathology results, within the EHR used by their providers to view laboratory results. Results were evaluated for accuracy, presence of required elements, and usability. Both normal and abnormal results were reviewed for tests, some of which were performed in-house and others at a reference laboratory. Results Overall accuracy for test results transmitted to the EHR was greater than 99.3% (1052 of 1059). There was lower compliance for completeness of test results, with 69.6% (732 of 1051) of the test results containing all essential reporting elements. Institutions that had fewer than half of their orders entered electronically had lower test result completeness rates. The rate of appropriate formatting of results was 90.9% (98 of 1010). Conclusions The great majority of test results are accurately transmitted from the laboratory to the EHR; however, lower percentages are transmitted completely and in a useable format. Laboratories should verify the accuracy, completeness, and format of test results at the time of test implementation, after test changes, and periodically. PMID:27575266

  8. Launching a Laboratory Testing Process Quality Improvement Toolkit: From the Shared Networks of Colorado Ambulatory Practices and Partners (SNOCAP).

    PubMed

    Fernald, Douglas; Hamer, Mika; James, Kathy; Tutt, Brandon; West, David

    2015-01-01

    Family medicine and internal medicine physicians order diagnostic laboratory tests for nearly one-third of patient encounters in an average week, yet among medical errors in primary care, an estimated 15% to 54% are attributed to laboratory testing processes. From a practice improvement perspective, we (1) describe the need for laboratory testing process quality improvements from the perspective of primary care practices, and (2) describe the approaches and resources needed to implement laboratory testing process quality improvements in practice. We applied practice observations, process mapping, and interviews with primary care practices in the Shared Networks of Colorado Ambulatory Practices and Partners (SNOCAP)-affiliated practice-based research networks that field-tested in 2013 a laboratory testing process improvement toolkit. From the data collected in each of the 22 participating practices, common testing quality issues included, but were not limited to, 3 main testing process steps: laboratory test preparation, test tracking, and patient notification. Three overarching qualitative themes emerged: practices readily acknowledge multiple laboratory testing process problems; practices know that they need help addressing the issues; and practices face challenges with finding patient-centered solutions compatible with practice priorities and available resources. While practices were able to get started with guidance and a toolkit to improve laboratory testing processes, most did not seem able to achieve their quality improvement aims unassisted. Providing specific guidance tools with practice facilitation or other rapid-cycle quality improvement support may be an effective approach to improve common laboratory testing issues in primary care. © Copyright 2015 by the American Board of Family Medicine.

  9. [Laboratory diagnosis of lipid imbalance].

    PubMed

    Siemianowicz, K

    1996-01-01

    Accurate diagnosis of hyperlipidaemia is necessary for the effective treatment. Measurements in serum or plasma obtained after an overnight fast of over 16 hours should include total cholesterol, triglycerides and HDL-cholesterol concentrations; LDL-cholesterol can be calculated using the Friedelwald's formula. Lipoprotein electrophoresis is used to define different phenotypes of hyperlipoproteinaemia according to the Fredrickson's classification. More sophisticated tests include apolipoprotein analysis, determination of Lp(a) concentration, activities of enzymes involved in lipid metabolism and genetic studies. Secondary causes of hyperlipidaemia, including liver, kidney, endocrine disorders should be excluded using the laboratory methods.

  10. NASA Glenn's Acoustical Testing Laboratory Awarded Accreditation by the National Voluntary Laboratory Accreditation Program

    NASA Technical Reports Server (NTRS)

    Akers, James C.; Cooper, Beth A.

    2004-01-01

    NASA Glenn Research Center's Acoustical Testing Laboratory (ATL) provides a comprehensive array of acoustical testing services, including sound pressure level, sound intensity level, and sound-power-level testing per International Standards Organization (ISO)1 3744. Since its establishment in September 2000, the ATL has provided acoustic emission testing and noise control services for a variety of customers, particularly microgravity space flight hardware that must meet International Space Station acoustic emission requirements. The ATL consists of a 23- by 27- by 20-ft (height) convertible hemi/anechoic test chamber and a separate sound-attenuating test support enclosure. The ATL employs a personal-computer-based data acquisition system that provides up to 26 channels of simultaneous data acquisition with real-time analysis (ref. 4). Specialized diagnostic tools, including a scanning sound-intensity system, allow the ATL's technical staff to support its clients' aggressive low-noise design efforts to meet the space station's acoustic emission requirement. From its inception, the ATL has pursued the goal of developing a comprehensive ISO 17025-compliant quality program that would incorporate Glenn's existing ISO 9000 quality system policies as well as ATL-specific technical policies and procedures. In March 2003, the ATL quality program was awarded accreditation by the National Voluntary Laboratory Accreditation Program (NVLAP) for sound-power-level testing in accordance with ISO 3744. The NVLAP program is administered by the National Institutes of Standards and Technology (NIST) of the U.S. Department of Commerce and provides third-party accreditation for testing and calibration laboratories. There are currently 24 NVLAP-accredited acoustical testing laboratories in the United States. NVLAP accreditation covering one or more specific testing procedures conducted in accordance with established test standards is awarded upon successful completion of an intensive

  11. The Evolution of the Language Laboratory: Changes During Fifteen Years of Operation

    ERIC Educational Resources Information Center

    Stack, Edward M.

    1977-01-01

    This article summarizes conditions and changes in language laboratories. Types of laboratories and equipment are listed; laboratory personnel include technicians, librarians and student assistants. Most maintenance was done by institution personnel; student use is outlined. Professional attitudes and equipment statistics are surveyed. (CHK)

  12. The comparative immunology of wild and laboratory mice, Mus musculus domesticus

    PubMed Central

    Abolins, Stephen; King, Elizabeth C.; Lazarou, Luke; Weldon, Laura; Hughes, Louise; Drescher, Paul; Raynes, John G.; Hafalla, Julius C. R.; Viney, Mark E.; Riley, Eleanor M.

    2017-01-01

    The laboratory mouse is the workhorse of immunology, used as a model of mammalian immune function, but how well immune responses of laboratory mice reflect those of free-living animals is unknown. Here we comprehensively characterize serological, cellular and functional immune parameters of wild mice and compare them with laboratory mice, finding that wild mouse cellular immune systems are, comparatively, in a highly activated (primed) state. Associations between immune parameters and infection suggest that high level pathogen exposure drives this activation. Moreover, wild mice have a population of highly activated myeloid cells not present in laboratory mice. By contrast, in vitro cytokine responses to pathogen-associated ligands are generally lower in cells from wild mice, probably reflecting the importance of maintaining immune homeostasis in the face of intense antigenic challenge in the wild. These data provide a comprehensive basis for validating (or not) laboratory mice as a useful and relevant immunological model system. PMID:28466840

  13. CTBTO Contractor Laboratory Test Sample Production Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bob Hague; Tracy Houghton; Nick Mann

    2013-08-01

    In October 2012 scientists from both Idaho National Laboratory (INL) and the CTBTO contact laboratory at Seibersdorf, Austria designed a system and capability test to determine if the INL could produce and deliver a short lived radio xenon standard in time for the standard to be measured at the CTBTO contact laboratory at Seibersdorf, Austria. The test included sample standard transportation duration and potential country entrance delays at customs. On October 23, 2012 scientists at the Idaho National Laboratory (INL) prepared and shipped a Seibersdorf contract laboratory supplied cylinder. The canister contained 1.0 scc of gas that consisted of 70%more » xenon and 30% nitrogen by volume. The t0 was October 24, 2012, 1200 ZULU. The xenon content was 0.70 +/ 0.01 scc at 0 degrees C. The 133mXe content was 4200 +/ 155 dpm per scc of stable xenon on t0 (1 sigma uncertainty). The 133Xe content was 19000 +/ 800 dpm per scc of stable xenon on t0 (1 sigma uncertainty).« less

  14. Extrapolating non-target risk of Bt crops from laboratory to field.

    PubMed

    Duan, Jian J; Lundgren, Jonathan G; Naranjo, Steve; Marvier, Michelle

    2010-02-23

    The tiered approach to assessing ecological risk of insect-resistant transgenic crops assumes that lower tier laboratory studies, which expose surrogate non-target organisms to high doses of insecticidal proteins, can detect harmful effects that might be manifested in the field. To test this assumption, we performed meta-analyses comparing results for non-target invertebrates exposed to Bacillus thuringiensis (Bt) Cry proteins in laboratory studies with results derived from independent field studies examining effects on the abundance of non-target invertebrates. For Lepidopteran-active Cry proteins, laboratory studies correctly predicted the reduced field abundance of non-target Lepidoptera. However, laboratory studies incorporating tri-trophic interactions of Bt plants, herbivores and parasitoids were better correlated with the decreased field abundance of parasitoids than were direct-exposure assays. For predators, laboratory tri-trophic studies predicted reduced abundances that were not realized in field studies and thus overestimated ecological risk. Exposure to Coleopteran-active Cry proteins did not significantly reduce the laboratory survival or field abundance of any functional group examined. Our findings support the assumption that laboratory studies of transgenic insecticidal crops show effects that are either consistent with, or more conservative than, those found in field studies, with the important caveat that laboratory studies should explore all ecologically relevant routes of exposure.

  15. Initial Public Health Laboratory Response After Hurricane Maria - Puerto Rico, 2017.

    PubMed

    Concepción-Acevedo, Jeniffer; Patel, Anita; Luna-Pinto, Carolina; Peña, Rafael González; Cuevas Ruiz, Rosa Ivette; Arbolay, Héctor Rivera; Toro, Mayra; Deseda, Carmen; De Jesus, Victor R; Ribot, Efrain; Gonzalez, Jennifer-Quiñones; Rao, Gouthami; De Leon Salazar, Alfonsina; Ansbro, Marisela; White, Brunilís B; Hardy, Margaret C; Georgi, Joaudimir Castro; Stinnett, Rita; Mercante, Alexandra M; Lowe, David; Martin, Haley; Starks, Angela; Metchock, Beverly; Johnston, Stephanie; Dalton, Tracy; Joglar, Olga; Stafford, Cortney; Youngblood, Monica; Klein, Katherine; Lindstrom, Stephen; Berman, LaShondra; Galloway, Renee; Schafer, Ilana J; Walke, Henry; Stoddard, Robyn; Connelly, Robin; McCaffery, Elaine; Rowlinson, Marie-Claire; Soroka, Stephen; Tranquillo, Darin T; Gaynor, Anne; Mangal, Chris; Wroblewski, Kelly; Muehlenbachs, Atis; Salerno, Reynolds M; Lozier, Matthew; Sunshine, Brittany; Shapiro, Craig; Rose, Dale; Funk, Renee; Pillai, Satish K; O'Neill, Eduardo

    2018-03-23

    Hurricane Maria made landfall in Puerto Rico on September 20, 2017, causing major damage to infrastructure and severely limiting access to potable water, electric power, transportation, and communications. Public services that were affected included operations of the Puerto Rico Department of Health (PRDOH), which provides critical laboratory testing and surveillance for diseases and other health hazards. PRDOH requested assistance from CDC for the restoration of laboratory infrastructure, surveillance capacity, and diagnostic testing for selected priority diseases, including influenza, rabies, leptospirosis, salmonellosis, and tuberculosis. PRDOH, CDC, and the Association of Public Health Laboratories (APHL) collaborated to conduct rapid needs assessments and, with assistance from the CDC Foundation, implement a temporary transport system for shipping samples from Puerto Rico to the continental United States for surveillance and diagnostic and confirmatory testing. This report describes the initial laboratory emergency response and engagement efforts among federal, state, and nongovernmental partners to reestablish public health laboratory services severely affected by Hurricane Maria. The implementation of a sample transport system allowed Puerto Rico to reinitiate priority infectious disease surveillance and laboratory testing for patient and public health interventions, while awaiting the rebuilding and reinstatement of PRDOH laboratory services.

  16. Space Resources for Teachers: Biology, Including Suggestions for Classroom Activities and Laboratory Experiments.

    ERIC Educational Resources Information Center

    Lee, Tom E.; And Others

    This compilation of resource units concerns the latest developments in space biology. Some of the topics included are oxygen consumption, temperature, radiation, rhythms, weightlessness, acceleration and vibration stress, toxicity, and sensory and perceptual problems. Many of the topics are interdisciplinary and relate biology, physiology,…

  17. Review and comparison of quality standards, guidelines and regulations for laboratories.

    PubMed

    Datema, Tjeerd A M; Oskam, Linda; Klatser, Paul R

    2012-01-01

    The variety and number of laboratory quality standards, guidelines and regulations (hereafter: quality documents) makes it difficult to choose the most suitable one for establishing and maintaining a laboratory quality management system. There is a need to compare the characteristics, suitability and applicability of quality documents in view of the increasing efforts to introduce quality management in laboratories, especially in clinical diagnostic laboratories in low income and middle income countries. This may provide valuable insights for policy makers developing national laboratory policies, and for laboratory managers and quality officers in choosing the most appropriate quality document for upgrading their laboratories. We reviewed the history of quality document development and then selected a subset based on their current use. We analysed these documents following a framework for comparison of quality documents that was adapted from the Clinical Laboratory Standards Institute guideline GP26 Quality management system model for clinical laboratory services . Differences were identified between national and international, and non-clinical and clinical quality documents. The most salient findings were the absence of provisions on occurrence management and customer service in almost all non-clinical quality documents, a low number of safety requirements aimed at protecting laboratory personnel in international quality documents and no requirements regarding ethical behaviour in almost all quality documents. Each laboratory needs to investigate whether national regulatory standards are present. These are preferred as they most closely suit the needs of laboratories in the country. A laboratory should always use both a standard and a guideline: a standard sums up the requirements to a quality management system, a guideline describes how quality management can be integrated in the laboratory processes.

  18. Standard Specifications for Language Laboratory.

    ERIC Educational Resources Information Center

    North Carolina State Dept. of Administration, Raleigh.

    Specifications are presented covering the components of electronic and electro-mechanical equipment, non-electrical materials for the teacher-student positions, and other items of a miscellaneous nature to provide for a complete, workable language laboratory facility. Instructions for the use of specifications are included for the purchaser,…

  19. Laboratory Exercise on Active Transport.

    ERIC Educational Resources Information Center

    Stalheim-Smith, Ann; Fitch, Greg K.

    1985-01-01

    Describes a laboratory exercise which demonstrates qualitatively the specificity of the transport mechanism, including a consideration of the competitive inhibition, and the role of adenosine triphosphate (ATP) in active transport. The exercise, which can be completed in two to three hours by groups of four students, consistently produces reliable…

  20. Laboratory diagnosis of ophthalmic sarcoidosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weinreb, R.N.; Tessler, H.

    Because the eye is involved in about 25% of patients with active sarcoid, the ophthalmologist is often the first physician to see these patients. Although clinical findings may suggest sarcoid, laboratory tests (e.g., x-ray, skin tests, blood chemistries, etc.) may be normal or inconclusive. Thus, it is important that the ophthalmologist be aware of the availability and limitations of the various biochemical, immunological, radiological, and histopathological tests that contribute to the early diagnosis of sarcoidosis. The authors review diagnostic procedures and present a flowchart detailing indications for each.