Sample records for laboratory fume hood

  1. Energy efficient laboratory fume hood

    DOEpatents

    Feustel, Helmut E.

    2000-01-01

    The present invention provides a low energy consumption fume hood that provides an adequate level of safety while reducing the amount of air exhausted from the hood. A low-flow fume hood in accordance with the present invention works on the principal of providing an air supply, preferably with low turbulence intensity, in the face of the hood. The air flow supplied displaces the volume currently present in the hood's face without significant mixing between the two volumes and with minimum injection of air from either side of the flow. This air flow provides a protective layer of clean air between the contaminated low-flow fume hood work chamber and the laboratory room. Because this protective layer of air will be free of contaminants, even temporary mixing between the air in the face of the fume hood and room air, which may result from short term pressure fluctuations or turbulence in the laboratory, will keep contaminants contained within the hood. Protection of the face of the hood by an air flow with low turbulence intensity in accordance with a preferred embodiment of the present invention largely reduces the need to exhaust large amounts of air from the hood. It has been shown that exhaust air flow reductions of up to 75% are possible without a decrease in the hood's containment performance.

  2. Low flow fume hood

    DOEpatents

    Bell, Geoffrey C.; Feustel, Helmut E.; Dickerhoff, Darryl J.

    2002-01-01

    A fume hood is provided having an adequate level of safety while reducing the amount of air exhausted from the hood. A displacement flow fume hood works on the principal of a displacement flow which displaces the volume currently present in the hood using a push-pull system. The displacement flow includes a plurality of air supplies which provide fresh air, preferably having laminar flow, to the fume hood. The displacement flow fume hood also includes an air exhaust which pulls air from the work chamber in a minimally turbulent manner. As the displacement flow produces a substantially consistent and minimally turbulent flow in the hood, inconsistent flow patterns associated with contaminant escape from the hood are minimized. The displacement flow fume hood largely reduces the need to exhaust large amounts of air from the hood. It has been shown that exhaust air flow reductions of up to 70% are possible without a decrease in the hood's containment performance. The fume hood also includes a number of structural adaptations which facilitate consistent and minimally turbulent flow within a fume hood.

  3. A comparative study for radiological decontamination of laboratory fume hood materials.

    PubMed

    Thomas, Elizabeth; Sweet, Lucas; MacFarlan, Paul; McNamara, Bruce; Kerschner, Harrison

    2012-08-01

    The efficacy for radiological decontamination of the laboratory standard fume hood as constructed of stainless steel, compared to that of powder-coated carbon steel is described. While the chemical inertness of powder-coated surfaces is good, faced with everyday abrasion, aggressive inorganic solutions and vapors, and penetrating organics commonly employed in government laboratory fume hoods, radiological decontamination of powder-coated steel surfaces was found to be similar to those made of stainless steel for easily solubilized or digestible radionuclides. Plutonium was difficult to remove from stainless steel and powder-coated surfaces, especially after prolonged contact times.

  4. Particle release and control of worker exposure during laboratory-scale synthesis, handling and simulated spills of manufactured nanomaterials in fume hoods

    NASA Astrophysics Data System (ADS)

    Fonseca, Ana S.; Kuijpers, Eelco; Kling, Kirsten I.; Levin, Marcus; Koivisto, Antti J.; Nielsen, Signe H.; Fransman, W.; Fedutik, Yijri; Jensen, Keld A.; Koponen, Ismo K.

    2018-02-01

    Fume hoods are one of the most common types of equipment applied to reduce the potential of particle exposure in laboratory environments. A number of previous studies have shown particle release during work with nanomaterials under fume hoods. Here, we assessed laboratory workers' inhalation exposure during synthesis and handling of CuO, TiO2 and ZnO in a fume hood. In addition, we tested the capacity of a fume hood to prevent particle release to laboratory air during simulated spillage of different powders (silica fume, zirconia TZ-3Y and TiO2). Airborne particle concentrations were measured in near field, far field, and in the breathing zone of the worker. Handling CuO nanoparticles increased the concentration of small particles (< 58 nm) inside the fume hood (up to 1 × 105 cm-3). Synthesis, handling and packaging of ZnO and TiO2 nanoparticles did not result in detectable particle release to the laboratory air. Simulated powder spills showed a systematic increase in the particle concentrations inside the fume hood with increasing amount of material and drop height. Despite powder spills were sometimes observed to eject into the laboratory room, the spill events were rarely associated with notable release of particles from the fume hood. Overall, this study shows that a fume hood generally offers sufficient exposure control during synthesis and handling of nanomaterials. An appropriate fume hood with adequate sash height and face velocity prevents 98.3% of particles release into the surrounding environment. Care should still be made to consider spills and high cleanliness to prevent exposure via resuspension and inadvertent exposure by secondary routes.

  5. Updating Older Fume Hoods.

    ERIC Educational Resources Information Center

    Saunders, G. Thomas

    1985-01-01

    Provides information on updating older fume hoods. Areas addressed include: (1) adjustment of the hood's back baffle; (2) hood air leakage; (3) light level; (4) hood location in relation to room traffic and room air; and (5) establishing and maintaining hood performance. (JN)

  6. Persistence of Change: Fume Hood Campaign Lessons

    ERIC Educational Resources Information Center

    Feder, Elah; Robinson, Jennifer; Wakefield, Sarah

    2012-01-01

    Purpose: Sustainability initiatives typically operate for a limited time period, but it is often unclear whether they have lasting effects. The purpose of this paper is to examine a laboratory fume hood campaign, in order to identify factors that might contribute or detract from long-term change persistence. Design/methodology/approach: The…

  7. Installation of a flow control device in an inclined air-curtain fume hood to control wake-induced exposure.

    PubMed

    Chen, Jia-Kun

    2016-08-01

    An inclined plate for flow control was installed at the lower edge of the sash of an inclined air-curtain fume hood to reduce the effects of the wake around a worker standing in front of the fume hood. Flow inside the fume hood is controlled by the inclined air-curtain and deflection plates, thereby forming a quad-vortex flow structure. Controlling the face velocity of the fume hood resulted in convex, straight, concave, and attachment flow profiles in the inclined air-curtain. We used the flow visualization and conducted a tracer gas test with a mannequin to determine the performance of two sash geometries, namely, the half-cylinder and inclined plate designs. When the half-cylinder design was used, the tracer gas test registered a high leakage concentration at Vf ≦ 57.1 fpm or less. This concentration occurred at the top of the sash opening, which was close to the breathing zone of the mannequin placed in front of the fume hood. When the inclined plate design was used, the containment was good, with concentrations of 0.002-0.004 ppm, at Vf ≦ 63.0 fpm. Results indicate that an inclined plate effectively reduces the leakage concentration induced by recirculation flow structures that form in the wake of a worker standing in front of an inclined air-curtain fume hood.

  8. Effects of boundary-layer separation controllers on a desktop fume hood.

    PubMed

    Huang, Rong Fung; Chen, Jia-Kun; Hsu, Ching Min; Hung, Shuo-Fu

    2016-10-02

    A desktop fume hood installed with an innovative design of flow boundary-layer separation controllers on the leading edges of the side plates, work surface, and corners was developed and characterized for its flow and containment leakage characteristics. The geometric features of the developed desktop fume hood included a rearward offset suction slot, two side plates, two side-plate boundary-layer separation controllers on the leading edges of the side plates, a slanted surface on the leading edge of the work surface, and two small triangular plates on the upper left and right corners of the hood face. The flow characteristics were examined using the laser-assisted smoke flow visualization technique. The containment leakages were measured by the tracer gas (sulphur hexafluoride) detection method on the hood face plane with a mannequin installed in front of the hood. The results of flow visualization showed that the smoke dispersions induced by the boundary-layer separations on the leading edges of the side plates and work surface, as well as the three-dimensional complex flows on the upper-left and -right corners of the hood face, were effectively alleviated by the boundary-layer separation controllers. The results of the tracer gas detection method with a mannequin standing in front of the hood showed that the leakage levels were negligibly small (≤0.003 ppm) at low face velocities (≥0.19 m/s).

  9. 10. LOOKING SOUTH IN BOP SHOP AT FUME HOOD AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. LOOKING SOUTH IN BOP SHOP AT FUME HOOD AND SPARE OXYGEN LANCES ON THE SERVICE FLOOR OF THE FURNACE AISLE. - U.S. Steel Duquesne Works, Basic Oxygen Steelmaking Plant, Along Monongahela River, Duquesne, Allegheny County, PA

  10. The Use of Feedback in Lab Energy Conservation: Fume Hoods at MIT

    ERIC Educational Resources Information Center

    Wesolowski, Daniel; Olivetti, Elsa; Graham, Amanda; Lanou, Steve; Cooper, Peter; Doughty, Jim; Wilk, Rich; Glicksman, Leon

    2010-01-01

    Purpose: The purpose of this paper is to report on the results of an Massachusetts Institute of Technology Chemistry Department campaign to reduce energy consumption in chemical fume hoods. Hood use feedback to lab users is a crucial component of this campaign. Design/methodology/approach: Sash position sensor data on variable air volume fume…

  11. EVALUATION OF LEAKAGE FROM FUME HOODS USING TRACER GAS, TRACER NANOPARTICLES AND NANOPOWDER HANDLING TEST METHODOLOGIES

    PubMed Central

    Dunn, Kevin H.; Tsai, Candace Su-Jung; Woskie, Susan R.; Bennett, James S.; Garcia, Alberto; Ellenbecker, Michael J.

    2015-01-01

    The most commonly reported control used to minimize workplace exposures to nanomaterials is the chemical fume hood. Studies have shown, however, that significant releases of nanoparticles can occur when materials are handled inside fume hoods. This study evaluated the performance of a new commercially available nano fume hood using three different test protocols. Tracer gas, tracer nanoparticle, and nanopowder handling protocols were used to evaluate the hood. A static test procedure using tracer gas (sulfur hexafluoride) and nanoparticles as well as an active test using an operator handling nanoalumina were conducted. A commercially available particle generator was used to produce sodium chloride tracer nanoparticles. Containment effectiveness was evaluated by sampling both in the breathing zone (BZ) of a mannequin and operator as well as across the hood opening. These containment tests were conducted across a range of hood face velocities (60, 80, and 100 feet/minute) and with the room ventilation system turned off and on. For the tracer gas and tracer nanoparticle tests, leakage was much more prominent on the left side of the hood (closest to the room supply air diffuser) although some leakage was noted on the right side and in the BZ sample locations. During the tracer gas and tracer nanoparticle tests, leakage was primarily noted when the room air conditioner was on for both the low and medium hood exhaust air flows. When the room air conditioner was turned off, the static tracer gas tests showed good containment across most test conditions. The tracer gas and nanoparticle test results were well correlated showing hood leakage under the same conditions and at the same sample locations. The impact of a room air conditioner was demonstrated with containment being adversely impacted during the use of room air ventilation. The tracer nanoparticle approach is a simple method requiring minimal setup and instrumentation. However, the method requires the reduction in

  12. Evaluation of leakage from fume hoods using tracer gas, tracer nanoparticles and nanopowder handling test methodologies.

    PubMed

    Dunn, Kevin H; Tsai, Candace Su-Jung; Woskie, Susan R; Bennett, James S; Garcia, Alberto; Ellenbecker, Michael J

    2014-01-01

    The most commonly reported control used to minimize workplace exposures to nanomaterials is the chemical fume hood. Studies have shown, however, that significant releases of nanoparticles can occur when materials are handled inside fume hoods. This study evaluated the performance of a new commercially available nano fume hood using three different test protocols. Tracer gas, tracer nanoparticle, and nanopowder handling protocols were used to evaluate the hood. A static test procedure using tracer gas (sulfur hexafluoride) and nanoparticles as well as an active test using an operator handling nanoalumina were conducted. A commercially available particle generator was used to produce sodium chloride tracer nanoparticles. Containment effectiveness was evaluated by sampling both in the breathing zone (BZ) of a mannequin and operator as well as across the hood opening. These containment tests were conducted across a range of hood face velocities (60, 80, and 100 ft/min) and with the room ventilation system turned off and on. For the tracer gas and tracer nanoparticle tests, leakage was much more prominent on the left side of the hood (closest to the room supply air diffuser) although some leakage was noted on the right side and in the BZ sample locations. During the tracer gas and tracer nanoparticle tests, leakage was primarily noted when the room air conditioner was on for both the low and medium hood exhaust airflows. When the room air conditioner was turned off, the static tracer gas tests showed good containment across most test conditions. The tracer gas and nanoparticle test results were well correlated showing hood leakage under the same conditions and at the same sample locations. The impact of a room air conditioner was demonstrated with containment being adversely impacted during the use of room air ventilation. The tracer nanoparticle approach is a simple method requiring minimal setup and instrumentation. However, the method requires the reduction in

  13. Energy Systems Fabrication Laboratory | Energy Systems Integration Facility

    Science.gov Websites

    Fabrication The fuel cell fabrication hub includes laboratory spaces with local exhaust and chemical fume hoods that support electrolysis and other chemical process research. Key Infrastructure Perchloric acid washdown hood, local exhaust, specialty gas manifolding, deionized water, chemical fume hoods, glassware

  14. Management Observation Facility Fume Hoods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sundsmo, V. A.

    I reviewed all the hoods used for AS&I work in buildings 253, 254, and 255. All have had the minimum annual surveys conducted and some have had semi-annual reviews. The operating parameter labels are posted consistent to the right or above right (with the only exception the perchloric acid hood in 1734- on the left) which facilitates users knowing where to check for information. All hoods with sash doors (except the SE one in 1734 have a note on the Operating Parameters label to "keep sash doors closed". Again, this was checking consistency. No surveys were missed.

  15. Orthogonal design on range hood with air curtain and its effects on kitchen environment.

    PubMed

    Liu, Xiaomin; Wang, Xing; Xi, Guang

    2014-01-01

    Conventional range hoods cannot effectively prevent the oil fumes containing cooking-induced harmful material from escaping into the kitchen Air curtains and guide plates have been used in range hoods to reduce the escape of airborne emissions and heat, thereby improving the kitchen environment and the cook's degree of comfort. In this article, numerical simulations are used to study the effects of the jet velocity of an air curtain, the jet angle of the air curtain, the width of the jet slot, the area of the guide plate, and the exhaust rate of the range hood on the perceived temperature, the perceived concentration of oil fumes, the release temperature of oil fumes, and the concentration of escaped oil fumes in a kitchen. The orthogonal experiment results show that the exhaust rate of the range hood is the main factor influencing the fumes concentration and the temperature distribution in the kitchen. For the range hood examined in the present study, the optimum values of the exhaust rate, the jet velocity of the air curtain, the jet angle of the air curtain, the width of the jet slot, and the area of the guide plate are 10.5 m(3)/min, 1.5 m/s, -5°, 4 mm, and 0.22 m(2), respectively, based on the results of the parametric study. In addition, the velocity field, temperature field, and oil fumes concentration field in the kitchen using the proposed range hood with the air curtain and guide plate are analyzed for those parameters. The study's results provide significant information needed for improving the kitchen environment.

  16. Protective smoke hood studies.

    DOT National Transportation Integrated Search

    1970-12-01

    The report describes the evaluation and testing of a high-temperature resistant, transparent, polyimide hood designed to protect aircraft passengers and crew from the effects of toxic fumes, smoke and flame resulting from an aircraft accident. As a '...

  17. Laboratory Ventilation and Safety.

    ERIC Educational Resources Information Center

    Steere, Norman V.

    1965-01-01

    In order to meet the needs of both safety and economy, laboratory ventilation systems must effectively remove air-borne toxic and flammable materials and at the same time exhaust a minimum volume of air. Laboratory hoods are the most commonly used means of removing gases, dusts, mists, vapors, and fumed from laboratory operations. To be effective,…

  18. Life Sciences Laboratory 2 Fan Exhaust Mixing Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flaherty, Julia E.; Antonio, Ernest J.

    An SF 6 tracer release was performed in the LSL-II ventilation stack over the weekend of March 5, 2016. The primary purpose of this study was to experimentally determine the gaseous concentration of material from a fume hood to the fan outlet, as well as at typical worker locations, to gain an understanding of potential worker exposures impacts. Five different fan operating configurations were utilized to ensure that the full spectrum of historical operating configurations was addressed. Some summary points from this study include: •Relatively high concentrations were observed within the stack area. –Between 50 and 100% of the exhaustmore » concentration may be observed within the stack. •Background concentrations were observed outside the stack area. –Workers outside the stack itself, but on the roof, are unlikely to be impacted by the exhaust. •Elevated concentrations on the order of 25% of the exhaust concentrations were observed within the Penthouse. •Transport time from a laboratory fume hood to the exhaust fan is within one to two minutes. •Penthouse concentrations climb from background levels to steady state over 15+ minutes. •Wind speed and wind direction did not play a significant role in the test outcomes. –A slight bias in the concentration distribution may be discernable based on wind speed and direction. •When both fans are operating, material from fume hoods on the east side preferentially flow through the east fan, while material from fume hoods on the west side preferentially flow through the west fan. This effectively doubles the concentration at that fan. This mixing study will inform other study components to develop a more complete picture of the worker potential exposure from LSL-II Rooftop activities. Estimating the mean concentration in the stack from chemical inventories and fume hood emissions for both current and historical laboratory activities is a separate effort. These estimates of mean ventilation concentrations

  19. Local exhaust ventilation for the control of welding fumes in the construction industry--a literature review.

    PubMed

    Flynn, Michael R; Susi, Pam

    2012-08-01

    Arc welding is a common unit operation in the construction industry, where frequent changes in location and welding position make it more difficult to control fume exposures than in industries where fixed locations are the norm. Welders may be exposed to a variety of toxic airborne contaminants including manganese (Mn) and hexavalent chromium (CrVI). Local exhaust ventilation (LEV) is a well-known engineering control for welding fumes but has not been adopted widely in the construction industry. This literature review presents data on the performance of a variety of LEV systems for welding fume control from the construction (five references), shipyard (five references), and other industries. The studies indicate that LEV can reduce fume exposures to total particulate, Mn, and CrVI to levels below currently relevant standards. Field studies suggest that 40-50% or more reduction in exposure is possible with portable or fixed LEV systems relative to natural ventilation but that correct positioning of the hood and adequate exhaust flow rates are essential. Successful implementation of extraction guns for gas metal arc welding (GMAW) and flux core arc welding has been demonstrated, indicating that a successful balance between extraction airflow and shielding gas requirements is possible. Work practices are an important part of achieving successful control of fume exposures; in particular, positioning the hood close to the arc, checking exhaust flow rates, and avoiding the plume. Further research is needed on hood size effects for controlling welding fume with portable LEV systems and identifying and overcoming barriers to LEV use in construction.

  20. 4. INTERIOR VIEW OF CHEMISTRY LAB LOOKING SOUTHEAST; NOTE FUME ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. INTERIOR VIEW OF CHEMISTRY LAB LOOKING SOUTHEAST; NOTE FUME EXHAUST HOOD AT LEFT & ORIGINAL CEILING FIXTURE - Fort McCoy, Building No. T-1033, North side of South Tenth Avenue, Block 10, Sparta, Monroe County, WI

  1. Performance of laboratories analysing welding fume on filter samples: results from the WASP proficiency testing scheme.

    PubMed

    Stacey, Peter; Butler, Owen

    2008-06-01

    This paper emphasizes the need for occupational hygiene professionals to require evidence of the quality of welding fume data from analytical laboratories. The measurement of metals in welding fume using atomic spectrometric techniques is a complex analysis often requiring specialist digestion procedures. The results from a trial programme testing the proficiency of laboratories in the Workplace Analysis Scheme for Proficiency (WASP) to measure potentially harmful metals in several different types of welding fume showed that most laboratories underestimated the mass of analyte on the filters. The average recovery was 70-80% of the target value and >20% of reported recoveries for some of the more difficult welding fume matrices were <50%. This level of under-reporting has significant implications for any health or hygiene studies of the exposure of welders to toxic metals for the types of fumes included in this study. Good laboratories' performance measuring spiked WASP filter samples containing soluble metal salts did not guarantee good performance when measuring the more complex welding fume trial filter samples. Consistent rather than erratic error predominated, suggesting that the main analytical factor contributing to the differences between the target values and results was the effectiveness of the sample preparation procedures used by participating laboratories. It is concluded that, with practice and regular participation in WASP, performance can improve over time.

  2. Hood College, Frederick National Laboratory Will Renew Popular Scientific Symposium | Frederick National Laboratory for Cancer Research

    Cancer.gov

    FREDERICK, Md. -- Hood College and the Frederick National Laboratory for Cancer Research have partnered to cohost an annual scientific symposium in the tradition of the landmark Oncogene Meeting, a national fixture in Frederick for more than 20 year

  3. Characteristics of PAHs from deep-frying and frying cooking fumes.

    PubMed

    Yao, Zhiliang; Li, Jing; Wu, Bobo; Hao, Xuewei; Yin, Yong; Jiang, Xi

    2015-10-01

    Cooking fumes are an important indoor source of polycyclic aromatic hydrocarbons (PAHs). Because indoor pollution has a more substantial impact on human health than outdoor pollution, PAHs from cooking fumes have drawn considerable attention. In this study, 16 PAHs emitted through deep-frying and frying methods using rapeseed, soybean, peanut, and olive oil were examined under a laboratory fume hood. Controlled experiments were conducted to collect gas- and particulate-phase PAHs emitted from the cooking oil fumes, and PAH concentrations were quantified via high-performance liquid chromatography (HPLC). The results show that deep-frying methods generate more PAHs and benzo[a]pyrene (B[a]P) (1.3 and 10.9 times, respectively) because they consume greater volumes of edible oil and involve higher oil temperatures relative to those of frying methods. In addition, the total B[a]Peq concentration of deep-frying is 2.2-fold larger than that of frying. Regarding the four types of edible oils studied, rapeseed oil produced more PAH emission than the other three oil varieties. For all of the cooking tests, three- and four-ringed PAHs were the main PAH components regardless of the food and oil used. Concerning the PAH partition between gas and particulate phase, the gaseous compounds accounted for 59-96 % of the total. Meanwhile, the particulate fraction was richer of high molecular weight PAHs (five-six rings). Deep-frying and frying were confirmed as important sources of PAH pollution in internal environments. The results of this study provide additional insights into the polluting features of PAHs produced via cooking activities in indoor environments.

  4. Vortex ventilation in the laboratory environment.

    PubMed

    Meisenzahl, Lawrence R

    2014-01-01

    Assured containment at low airflow has long eluded the users of ventilated enclosures including chemical fume hoods used throughout industry. It is proposed that containment will be enhanced in a hood that has a particular interior shape that causes a natural vortex to occur. The sustained vortex improves the containment of contaminants within the enclosure at low airflow. This hypothesis was tested using the ASHRAE 110 tracer gas test. A known volume of tracer gas was emitted in the hood. A MIRAN SapphIRe infrared spectrometer was used to measure the concentration of tracer gas that escapes the enclosure. The design of the experiment included a written operating procedure, data collection plan, and statistical analysis of the data. A chemical fume hood of traditional design was tested. The hood interior was then reconstructed to enhance the development of a vortex inside the enclosure. The hood was retested using the same method to compare the performance of the traditional interior shape with the enhanced vortex shape. In every aspect, the vortex hood showed significant improvement over the traditional hood design. Use of the Hood Index characterizing the dilution of gas in an air stream as a logarithmic function indicates a causal relationship between containment and volumetric airflow through an enclosure. Use of the vortex effect for ventilated enclosures can provide better protection for the user and lower operating cost for the owner. [Supplementary materials are available for this article. Go to the publisher's online edition of Journal of Occupational and Environmental Hygiene for the following free supplemental resource: a data collection spreadsheet, data analysis, and data collection procedure.].

  5. Metal fume fever and polymer fume fever.

    PubMed

    Greenberg, Michael I; Vearrier, David

    2015-05-01

    elucidated but may involve similar mechanisms to those proposed for metal fume fever. Metal fume fever typically presents with generally non-specific complaints including influenza-like symptoms, fever, shaking chills, arthalgias, myalgias, headache, and malaise. Onset of symptoms typically occurs 4-10 h following the exposure to metal-containing fumes. While metal fume fever is typically benign and self-limited, severe cases of the disease have been reported. In patients with ongoing metal fume exposure over the course of a workweek, tachyphylaxis occurs resulting in improvement in symptoms over the course of the workweek and maximal symptoms occurring after an exposure-free period such as a weekend. The clinical presentation of polymer fume fever is indistinguishable from metal fume fever, with an exposure history being necessary to distinguish the two entities. Chest radiographs are typically normal in cases of metal fume fever and polymer fume fever; however, mild vascular congestion may be demonstrated and severe cases may feature diffuse patchy infiltrates. Laboratory studies are typically not necessary but may demonstrate leukocytosis with leftward shift or an elevated erythrocyte sedimentation rate. The primary treatment for both metal fume fever and polymer fume fever is supportive and directed at symptom relief. Oral hydration, rest, and the use of antipyretics and anti-inflammatory medications (e.g., non-steroidal anti-inflammatory drugs and aspirin) are recommended. A careful workplace exposure assessment analysis conducted by an occupational medicine specialist or clinical toxicologist in concert with a qualified industrial hygienist should be performed. A careful workplace exposure assessment including measurement of ambient zinc and other metal (e.g., chrome, nickel, copper and manganese) fume concentrations or concentrations of fluorocarbon polymer decomposition products at different locations within the workplace should be performed. Metal fume fever is

  6. Increased levels of oxidative DNA damage attributable to cooking-oil fumes exposure among cooks.

    PubMed

    Ke, Yuebin; Cheng, Jinquan; Zhang, Zhicheng; Zhang, Renli; Zhang, Zhunzhen; Shuai, Zhihong; Wu, Tangchun

    2009-07-01

    Previous investigations have indicated that cooks are exposed to polycyclic aromatic hydrocarbons (PAHs) from cooking-oil fumes. However, Emission of PAH and their carcinogenic potencies from cooking oil fumes sources have not been investigated among cooks. To investigate the urinary excretion of a marker for oxidative DNA damage, 8-hydroxydeoxyguanosine (8-OHdG), in different groups of cooks and different exposure groups, and to study the association between 8-OHdG and 1-hydroxypyrene(1-OHP), a biological marker for PAH exposure. Urine samples were collected from different groups of cooks (n = 86) and from unexposed controls (n = 36); all were male with similar age and smoking habits. The health status, occupational history, smoking, and alcohol consumption 24 h prior to sampling was estimated from questionnaires. The urine samples were frozen for later analyses of 8-OHdG and 1-OHP levels by high-performance liquid chromatography. Excretion in urine of 8-OHdG was similar for controls (mean 1.2micromol/mol creatinine, n = 36), and for those who had been in the kitchen with an exhaust-hood operating (mean 1.5micromol/mol creatinine, n = 45). Cooks exposed to cooking-oil fumes without exhaust-hood operation had significantly increased excretion of 8-OHdG (mean 2.3micromol/mol creatinine, n = 18), compared with controls. The urinary levels of ln 1-OHP and ln 8-OHdG were still significantly correlated in a multiple regression analysis. The results indicate that exposure to PAH or possibly other compounds in cooking-oil fumes may cause oxidative DNA damage.

  7. Preparation and Certification of Two New Bulk Welding Fume Reference Materials for Use in Laboratories Undertaking Analysis of Occupational Hygiene Samples

    PubMed Central

    Butler, Owen; Musgrove, Darren; Stacey, Peter

    2014-01-01

    Workers can be exposed to fume, arising from welding activities, which contain toxic metals and metalloids. Occupational hygienists need to assess and ultimately minimize such exposure risks. The monitoring of the concentration of particles in workplace air is one assessment approach whereby fume, from representative welding activities, is sampled onto a filter and returned to a laboratory for analysis. Inductively coupled plasma-atomic emission spectrometry and inductively coupled plasma-mass spectrometry are generally employed as instrumental techniques of choice for the analysis of such filter samples. An inherent difficulty, however, with inductively coupled plasma-based analytical techniques is that they typically require a sample to be presented for analysis in the form of a solution. The efficiency of the required dissolution step relies heavily upon the skill and experience of the analyst involved. A useful tool in assessing the efficacy of this dissolution step would be the availability and subsequent analysis of welding fume reference materials with stated elemental concentrations and matrices that match as closely as possible the matrix composition of welding fume samples submitted to laboratories for analysis. This article describes work undertaken at the Health and Safety Laboratory to prepare and certify two new bulk welding fume reference materials that can be routinely used by analysts to assess the performance of the digestion procedures they employ in their laboratories. PMID:24499055

  8. Preparation and certification of two new bulk welding fume reference materials for use in laboratories undertaking analysis of occupational hygiene samples.

    PubMed

    Butler, Owen; Musgrove, Darren; Stacey, Peter

    2014-01-01

    Workers can be exposed to fume, arising from welding activities, which contain toxic metals and metalloids. Occupational hygienists need to assess and ultimately minimize such exposure risks. The monitoring of the concentration of particles in workplace air is one assessment approach whereby fume, from representative welding activities, is sampled onto a filter and returned to a laboratory for analysis. Inductively coupled plasma-atomic emission spectrometry and inductively coupled plasma-mass spectrometry are generally employed as instrumental techniques of choice for the analysis of such filter samples. An inherent difficulty, however, with inductively coupled plasma-based analytical techniques is that they typically require a sample to be presented for analysis in the form of a solution. The efficiency of the required dissolution step relies heavily upon the skill and experience of the analyst involved. A useful tool in assessing the efficacy of this dissolution step would be the availability and subsequent analysis of welding fume reference materials with stated elemental concentrations and matrices that match as closely as possible the matrix composition of welding fume samples submitted to laboratories for analysis. This article describes work undertaken at the Health and Safety Laboratory to prepare and certify two new bulk welding fume reference materials that can be routinely used by analysts to assess the performance of the digestion procedures they employ in their laboratories.

  9. Thermal protective uniforms and hoods: impact of design modifications and water content on burn prevention in New York City firefighters: laboratory and field results

    PubMed Central

    Prezant, D; Malley, K; Barker, R; Guerth, C; Kelly, K

    2001-01-01

    Objectives—To determine (1) the effectiveness of hoods in reducing head burns, (2) the impact of clothes worn under the protective outer uniform (modern = long sleeve shirt and long pants; modified modern = short sleeve T-shirt and short pants) on burns, and (3) whether water content (dry, damp or saturated) affects the level of thermal protection. Setting—Fire Department of the City of New York (FDNY). Methods—Laboratory tests (fully dressed manikin) evaluated the different uniform and water conditions when exposed to an average 24 cal/cm2 heat flux, approximately 2250°F air temperature. FDNY field results compared (1) head burns during winters wearing the hood to winters without hood and (2) upper and lower extremity burns during summers wearing traditional, modern, and modified modern uniforms. Results—Laboratory tests showed that thermal protection was: (1) dramatically improved by the hood with protection increasing as water content increased and (2) not significantly different between modern and modified modern uniforms, regardless of water content. FDNY field results confirmed these tests showing (1) significant decreases in neck burns (by 54%), ear burns (by 60%), and head burn totals (by 46%) wearing the hood and (2) no significant differences in upper or lower extremity burns wearing modern compared with modified modern uniforms. Conclusions—Based on combined laboratory and field results, we strongly recommend the use of modern thermal protective hoods and the modified modern uniform. PMID:11565971

  10. Evaluation of operational parameters role on the emission of fumes.

    PubMed

    Sajedifar, Javad; Kokabi, Amir Hossein; Farhang Dehghan, Somayeh; Mehri, Ahmad; Azam, Kamal; Golbabaei, Farideh

    2017-12-12

    Electric arc welding is a routine operation in the construction of metallic structures, but the fumes generated during the welding process can threaten the health of welders. Fumes are undesirable products of the majority of welding operations and may have various detrimental effects on health. The purpose of this study was to investigate the effect of operational parameters of the shielded metal arc welding (SMAW) process on the emission of fumes. A dust monitor was used to measure the number and mass concentration of fumes generated by SMAW. Measurements were made at the distances of 23cm (hood inlet) and 41cm (welder\\'s breathing zone) from the weld point, with different values assigned to three operational parameters, namely current intensity, travel speed, and heat input (HI). Number concentration (NC) decreased with the increase in particle size. The highest mass concentrations (MC) were observed for MC1 (0.35μm-0.5μm) and MC8 (Larger than 6.5μm). For reducing exposures to fumes, welders are recommended to use the lowest voltage and amperage and the highest travel speed to the extent that does not compromise in the quality of welds. For assessment of exposure to airborne particles in industrial workplaces and specially in welding operations, it is thought that taking, solely, mass concentration in to consideration and lack of attention to number concentration would not be able to reflect accurate assessment of the adverse effects of particles on the body organs.

  11. 78 FR 48866 - Nationwide Categorical Waivers Under the American Recovery and Reinvestment Act of 2009 (Recovery...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-12

    ... and hood fume interface with Phoenix Controls hood. The components were specifically designed to fit... Module Assembly to repair existing Johnson Controls Lab and Hood Fume Interface with Phoenix Controls... Johnson Controls lab and hood fume interface with Phoenix Controls hood (where utilization of an American...

  12. A Low-Cost, Effective, Fumes Exhaust System.

    ERIC Educational Resources Information Center

    Jacobs, C. O.

    1979-01-01

    Discusses the importance of avoiding welding fumes. The sources of these fumes are presented in a table. Criticizes currently used ventilation systems and reviews the Occupational Safety and Health Act requirements. Describes a low-cost exhaust system developed for agricultural mechanics laboratories. (LRA)

  13. Performance assessment of U.S. residential cooking exhaust hoods.

    PubMed

    Delp, William W; Singer, Brett C

    2012-06-05

    This study assessed the performance of seven new residential cooking exhaust hoods representing common U.S. designs. Laboratory tests were conducted to determine fan curves relating airflow to duct static pressure, sound levels, and exhaust gas capture efficiency for front and back cooktop burners and the oven. Airflow rate sensitivity to duct flow resistance was higher for axial fan devices than for centrifugal fan devices. Pollutant capture efficiency (CE) ranged from <15% to >98%, varying across hoods and with airflow and burner position for each hood. CE was higher for back burners relative to front burners, presumably because most hoods covered only part of the front burners. Open hoods had higher CE than those with grease screen and metal-covered bottoms. The device with the highest CE--exceeding 80% for oven and front burners--had a large, open hood that covered most of the front burners. The airflow rate for this hood surpassed the industry-recommended level of 118 L·s(-1) (250 cfm) and produced sound levels too high for normal conversation. For hoods meeting the sound and fan efficacy criteria for Energy Star, CE was <30% for front and oven burners.

  14. Manganese speciation of laboratory-generated welding fumes

    PubMed Central

    Andrews, Ronnee N.; Keane, Michael; Hanley, Kevin W.; Feng, H. Amy; Ashley, Kevin

    2015-01-01

    The objective of this laboratory study was to identify and measure manganese (Mn) fractions in chamber-generated welding fumes (WF) and to evaluate and compare the results from a sequential extraction procedure for Mn fractions with that of an acid digestion procedure for measurement of total, elemental Mn. To prepare Mn-containing particulate matter from representative welding processes, a welding system was operated in short circuit gas metal arc welding (GMAW) mode using both stainless steel (SS) and mild carbon steel (MCS) and also with flux cored arc welding (FCAW) and shielded metal arc welding (SMAW) using MCS. Generated WF samples were collected onto polycarbonate filters before homogenization, weighing and storage in scintillation vials. The extraction procedure consisted of four sequential steps to measure various Mn fractions based upon selective solubility: (1) soluble Mn dissolved in 0.01 M ammonium acetate; (2) Mn (0,II) dissolved in 25 % (v/v) acetic acid; (3) Mn (III,IV) dissolved in 0.5% (w/v) hydroxylamine hydrochloride in 25% (v/v) acetic acid; and (4) insoluble Mn extracted with concentrated hydrochloric and nitric acids. After sample treatment, the four fractions were analyzed for Mn by inductively coupled plasma-atomic emission spectroscopy (ICP-AES). WF from GMAW and FCAW showed similar distributions of Mn species, with the largest concentrations of Mn detected in the Mn (0,II) and insoluble Mn fractions. On the other hand, the majority of the Mn content of SMAW fume was detected as Mn (III,IV). Although the concentration of Mn measured from summation of the four sequential steps was statistically significantly different from that measured from the hot block dissolution method for total Mn, the difference is small enough to be of no practical importance for industrial hygiene air samples, and either method may be used for Mn measurement. The sequential extraction method provides valuable information about the oxidation state of Mn in samples

  15. Manganese speciation of laboratory-generated welding fumes.

    PubMed

    Andrews, Ronnee N; Keane, Michael; Hanley, Kevin W; Feng, H Amy; Ashley, Kevin

    The objective of this laboratory study was to identify and measure manganese (Mn) fractions in chamber-generated welding fumes (WF) and to evaluate and compare the results from a sequential extraction procedure for Mn fractions with that of an acid digestion procedure for measurement of total, elemental Mn. To prepare Mn-containing particulate matter from representative welding processes, a welding system was operated in short circuit gas metal arc welding (GMAW) mode using both stainless steel (SS) and mild carbon steel (MCS) and also with flux cored arc welding (FCAW) and shielded metal arc welding (SMAW) using MCS. Generated WF samples were collected onto polycarbonate filters before homogenization, weighing and storage in scintillation vials. The extraction procedure consisted of four sequential steps to measure various Mn fractions based upon selective solubility: (1) soluble Mn dissolved in 0.01 M ammonium acetate; (2) Mn (0,II) dissolved in 25 % (v/v) acetic acid; (3) Mn (III,IV) dissolved in 0.5% (w/v) hydroxylamine hydrochloride in 25% (v/v) acetic acid; and (4) insoluble Mn extracted with concentrated hydrochloric and nitric acids. After sample treatment, the four fractions were analyzed for Mn by inductively coupled plasma-atomic emission spectroscopy (ICP-AES). WF from GMAW and FCAW showed similar distributions of Mn species, with the largest concentrations of Mn detected in the Mn (0,II) and insoluble Mn fractions. On the other hand, the majority of the Mn content of SMAW fume was detected as Mn (III,IV). Although the concentration of Mn measured from summation of the four sequential steps was statistically significantly different from that measured from the hot block dissolution method for total Mn, the difference is small enough to be of no practical importance for industrial hygiene air samples, and either method may be used for Mn measurement. The sequential extraction method provides valuable information about the oxidation state of Mn in samples

  16. Hood entry coefficients of compound exhaust hoods.

    PubMed

    Figueroa, Crescente E

    2011-12-01

    A traditional method for assessing the flow rate in ventilation systems is based on multiple readings of velocity or velocity pressure (VP) (usually 10 or 20 points) taken in ductwork sections located away from fittings (> seven × diameters of straight duct). This study seeks to eliminate the need for a multiple-point evaluation and replace it with a simplified method that requires only a single measurement of hood static pressure (SP(h)) taken at a more accessible location (< three × diameters of straight duct from the hood entry). The SP(h) method is widely used for the assessment of flow rate in simple hoods. However, industrial applications quite often use compound hoods that are regularly of the slot/plenum type. For these hoods, a "compound coefficient of entry" has not been published, which makes the use of the hood static pressure method unfeasible. This study proposes a model for the computation of a "compound coefficient of entry" and validates the use of this model to assess flow rate in two systems of well-defined geometry (multi-slotted/plenum and single-slotted/tapered or "fish-tail" types). When using a conservative value of the slot loss factor (1.78), the proposed model yielded an estimate of the volumetric flow rate within 10% of that provided by a more comprehensive method of assessment. The simplicity of the hood static pressure method makes it very desirable, even in the upper range of experimental error found in this study.

  17. Safety in the SEM laboratory--1981 update

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bance, G.N.; Barber, V.C.; Sholdice, J.A.

    1981-01-01

    The article reviews recent information on hazards as they relate to safety in SEM laboratories. The first section lists the safety equipment that should be available in a SEM laboratory. Flammable and combustible liquids are discussed, and particular warnings are given concerning the fire and explosion risks associated with diethyl ether and diisopropyl ether. The possible hazards associated with electrical equipment, and the risk of X-ray emissions from EM's are briefly outlined. The hazards associated with acute and chronic toxicity of chemicals used in the EM laboratory are discussed. The need to reduce exposure to a growing list of recognizablemore » hazardous chemicals is emphasized. This reduction can be accomplished by more extensive use of functioning fume hoods, and the use of more appropriate and effective protective gloves. Allergies and the hazards of dangerous pathogens in the SEM laboratory are discussed. The explosion and other hazards associated with cryogens, vacuum evaporators, critical point dryers, and compressed gas cylinders are emphasized.« less

  18. Design, construction, and characterization of a novel robotic welding fume generator and inhalation exposure system for laboratory animals.

    PubMed

    Antonini, James M; Afshari, Aliakbar A; Stone, Sam; Chen, Bean; Schwegler-Berry, Diane; Fletcher, W Gary; Goldsmith, W Travis; Vandestouwe, Kurt H; McKinney, Walter; Castranova, Vincent; Frazer, David G

    2006-04-01

    Respiratory effects observed in welders have included lung function changes, metal fume fever, bronchitis, and a possible increase in the incidence of lung cancer. Many questions remain unanswered regarding the causality and possible underlying mechanisms associated with the potential toxic effects of welding fume inhalation. The objective of the present study was to construct a completely automated, computer-controlled welding fume generation and inhalation exposure system to simulate real workplace exposures. The system comprised a programmable six-axis robotic welding arm, a water-cooled arc welding torch, and a wire feeder that supplied the wire to the torch at a programmed rate. For the initial studies, gas metal arc welding was performed using a stainless steel electrode. A flexible trunk was attached to the robotic arm of the welder and was used to collect and transport fume from the vicinity of the arc to the animal exposure chamber. Undiluted fume concentrations consistently ranged from 90-150 mg/m(3) in the animal chamber during welding. Temperature and humidity remained constant in the chamber during the welding operation. The welding particles were composed of (from highest to lowest concentration) iron, chromium, manganese, and nickel as measured by inductively coupled plasma atomic emission spectroscopy. Size distribution analysis indicated the mass median aerodynamic diameter of the generated particles to be approximately 0.24 microm with a geometric standard deviation (sigma(g)) of 1.39. As determined by transmission and scanning electron microscopy, the generated aerosols were mostly arranged as chain-like agglomerates of primary particles. Characterization of the laboratory-generated welding aerosol has indicated that particle morphology, size, and chemical composition are comparable to stainless steel welding fume generated in other studies. With the development of this novel system, it will be possible to establish an animal model using

  19. Performance of Hoods for Aircraft Exhaust-Gas Turbines

    DTIC Science & Technology

    1946-11-01

    vanes and hood-entrance fairing band at a blade -to- Jet speed ratio of 0.4 and a pressure ratio’ of 2.0. Aircraft Engine Research Laboratory... engine , the gases leave the turbine with an axial velocity of about 700 feet per second. At an airspeed of 375 miles_ per hour, a jet power...importance of providing efficient exhaust hoods for turbine - compressor jet -propulsion engines is even more obvious as all the power of these units is

  20. 10 CFR 433.5 - Performance level determination.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) Each Federal agency shall consider laboratory fume hoods and kitchen ventilation systems as part of the ASHRAE-covered HVAC loads subject to the 30 percent savings requirements, rather than as process loads. ...

  1. 10 CFR 433.5 - Performance level determination.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... loads). (b) Each Federal agency shall consider laboratory fume hoods and kitchen ventilation systems as part of the ASHRAE-covered HVAC loads subject to the 30 percent savings requirements, rather than as...

  2. 10 CFR 433.5 - Performance level determination.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) Each Federal agency shall consider laboratory fume hoods and kitchen ventilation systems as part of the ASHRAE-covered HVAC loads subject to the 30 percent savings requirements, rather than as process loads. ...

  3. [Association of cooking oil fumes exposure and oxidative DNA damage among occupational exposed populations].

    PubMed

    Ke, Yue-bin; Xu, Xin-yun; Yuan, Jian-hui; Fang, Shi-song; Liu, Yi-min; Wu, Tang-chun

    2010-08-01

    Previous investigations indicate that cooks are exposed to polycyclic aromatic hydrocarbons (PAH) from cooking oil fumes (COF). However, Emission of PAH and their carcinogenic potencies from cooking oil fumes sources have not been investigated among cooks. To investigate the urinary excretion of a marker for oxidative DNA damage, 8-hydroxydeoxyguanosine (8-OHdG), in different groups of cooks and different exposure groups, and to study the association between 8-OHdG and 1-hydroxypyrene (1-OHP), a biological marker for PAH exposure. Urine samples were collected from different groups of cooks (n = 86) and from unexposed controls (n = 36), all are male with similar age and smoking habits. The health status, occupational history, smoking, and alcohol consumption 24 hours prior to sampling was estimated from questionnaires. The urinary samples were frozen for later analyses of 8-OHdG and 1-OHP by high performance liquid chromatography. Excretion in urine of 8-OHdG were similar for controls (mean 1.2 µmol/mol creatinine, n = 36), and for those who had been in the kitchen room with exhaust hood operation (mean 1.5 µmol/mol creatinine, n = 45). COF exposed cooks without exhaust hood operation had increased excretion of 8-OHdG (mean 2.3 µmol/mol creatinine, n = 18). The difference between this group and the unexposed controls was significant. The urinary levels of ln 1-OHP and ln 8-OHdG were still significantly correlated in a multiple regression analysis. Results indicate that exposure to PAH or possibly other compounds in COF may cause oxidative DNA damage.

  4. Equipment & New Products.

    ERIC Educational Resources Information Center

    Poitras, Adrian W., Ed.

    1979-01-01

    Reviews new science equipment and products for the laboratory. Includes hand-held calculators, fiberglass fume hoods, motorized microtomy, disposable mouse cages, and electric timers. Describes 11 products total. Provides manufacturer name, address, and price. (MA)

  5. Maintenance and Testing of Fume Cupboard

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hussein, Falah H.; Al-Dahhan, Wedad H.; Al-Zuhairi, Ali Jassim

    Scientists at universities across Iraq are actively working to report actual incidents and accidents occurring in their laboratories, as well as structural improvements made to improve safety and security, to raise awareness and encourage openness, leading to widespread adoption of robust Chemical Safety and Security (CSS) practices. This manuscript highlights the importance of periodic maintenance on fume cupboards, and is the fourth in a series of five case studies describing laboratory incidents, accidents, and laboratory improvements. In this study, we describe a situation in which the ventilation capacity of the fume cupboard in the undergraduate chemistry laboratories at Al-Nahrain Universitymore » had decreased to an unacceptable level. The CSS Committee investigated and found the ducting system had been blocked by plastic sheets and dead birds. All the ducts have since been cleaned, and four extra ventilation fans have been installed to further increase ventilation capacity. By openly sharing what happened along with the lessons learned from the accident, we hope to minimize the possibility of another researcher being injured in a similar incident in the future.« less

  6. Manganese and welding fume exposure and control in construction.

    PubMed

    Meeker, John D; Susi, Pam; Flynn, Michael R

    2007-12-01

    Overexposure to welding fume constituents, particularly manganese, is of concern in the construction industry due to the prevalence of welding and the scarcity of engineering controls. The control effectiveness of a commercially available portable local exhaust ventilation (LEV) unit was assessed. It consisted of a portable vacuum and a small bell-shaped hood connected by a flexible 2 inch (50.8 mm) diameter hose, in both experimental and field settings. The experimental testing was done in a semienclosed booth at a pipefitter training facility. Five paired trials of LEV control vs. no control, each approximately 1 hr in duration and conducted during two successive welds of 6 inch (152.4 mm) diameter carbon steel pipe were run in random order. Breathing zone samples were collected outside the welding hood during each trial. In the field scenario, full-shift breathing zone samples were collected from two pipefitters welding carbon steel pipe for a chiller installation on a commercial construction project. Eight days of full-shift sampling were conducted on both workers (n = 16), and the LEV was used by one of the two workers on an alternating basis for 7 of the days. All samples were collected with personal sample pumps calibrated at 2 L/min. Filter cassettes were analyzed for total particulate and manganese concentration by a certified laboratory. In the experimental setting, use of the portable LEV resulted in a 75% reduction in manganese exposure (mean 13 microg/m(3) vs. 51 microg/m(3); p < 0.05) and a 60% reduction in total particulate (mean 0.74 mg/m(3) vs. 1.83 mg/m(3); p < 0.05). In the field setting, LEV use resulted in a 53% reduction in manganese exposure (geometric mean 46 microg/m(3) vs. 97 microg/m(3); p < 0.05) but only a 10% reduction in total particulate (geometric mean 4.5 mg/m(3) vs. 5.0 mg/m(3); p > 0.05). These results demonstrate that LEV use can reduce manganese exposure associated with welding tasks in construction.

  7. Alternatives for Benzene in the Extraction of Bitumen Fume from Exposure Sample Media.

    PubMed

    Sutter, Benjamin; Ravera, Christel; Hussard, Caroline; Langlois, Eddy

    2016-01-01

    Benzene is frequently used to extract collected bitumen fumes from personal sampler substrates. However, this solvent is particularly dangerous because of its carcinogenicity (group 1 of the International Agency for Research on Cancer classification). Therefore, to prevent the exposure of laboratory technicians to benzene during the fume extraction step from samplers, a compromise had to be found to identify a less toxic solvent with the same extraction capacity. To compare the extraction capacities of selected solvents, bitumen fumes were generated in the laboratory from three different batches of road surfacing bitumen collected on dedicated bitumen fume samplers. The samplers were then extracted by benzene and the solvents tested. Of 11 selected solvents less toxic than benzene and used in studies on bitumen and bitumen fume analyses, n-hexane and n-heptane were identified as alternatives to benzene. In particular, the results demonstrated that n-heptane was the best candidate solvent for benzene replacement, due to its extraction efficiency comparable to benzene for the three bitumen fumes tested and its low toxicity, which is highly compatible with benzene replacement. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  8. Pulmonary responses to welding fumes: role of metal constituents.

    PubMed

    Antonini, James M; Taylor, Michael D; Zimmer, Anthony T; Roberts, Jenny R

    2004-02-13

    It is estimated that more than 1 million workers worldwide perform some type of welding as part of their work duties. Epidemiology studies have shown that a large number of welders experience some type of respiratory illness. Respiratory effects seen in full-time welders have included bronchitis, siderosis, asthma, and a possible increase in the incidence of lung cancer. Pulmonary infections are increased in terms of severity, duration, and frequency among welders. Inhalation exposure to welding fumes may vary due to differences in the materials used and methods employed. The chemical properties of welding fumes can be quite complex. Most welding materials are alloy mixtures of metals characterized by different steels that may contain iron, manganese, chromium, and nickel. Animal studies have indicated that the presence and combination of different metal constituents is an important determinant in the potential pneumotoxic responses associated with welding fumes. Animal models have demonstrated that stainless steel (SS) welding fumes, which contain significant levels of nickel and chromium, induce more lung injury and inflammation, and are retained in the lungs longer than mild steel (MS) welding fumes, which contain mostly iron. In addition, SS fumes generated from welding processes using fluxes to protect the resulting weld contain elevated levels of soluble metals, which may affect respiratory health. Recent animal studies have indicated that the lung injury and inflammation induced by SS welding fumes that contain water-soluble metals are dependent on both the soluble and insoluble fractions of the fume. This article reviews the role that metals play in the pulmonary effects associated with welding fume exposure in workers and laboratory animals.

  9. Hood River Production Master Plan.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Toole, Patty

    1991-07-01

    The Northwest Power Planning Council's 1987 Columbia River Fish and Wildlife Program authorizes the development of artificial production facilities to raise chinook salmon and steelhead for enhancement in the Hood, Umatilla, Walla Walla, Grande Ronde and Imnaha rivers and elsewhere. On February 26, 1991 the Council agreed to disaggregate Hood River from the Northeast Oregon Hatchery Project, and instead, link the Hood River Master Plan (now the Hood River Production Plan) to the Pelton Ladder Project (Pelton Ladder Master Plan 1991).

  10. The Benefits of Mixed Flow Technology: Roof Exhaust Fans.

    ERIC Educational Resources Information Center

    Tetley, Paul A.

    2001-01-01

    Explores the problems associated with laboratory workstation exhaust faced by most colleges and universities and explains how the selection of a proper fume hood exhaust system can prevent or eliminate these problems and provide a clean and safe lab environment. Also highlighted are indoor air quality legal implications. (GR)

  11. Capture envelopes of rectangular hoods in cross drafts.

    PubMed

    Huang, R F; Sir, S Y; Chen, Y K; Yeh, W Y; Chen, C W; Chen, C C

    2001-01-01

    The suction fields of the rectangular hoods of various aspect ratios varying from 0.1 to 10 that are subject to the influence of cross drafts were experimentally studied in an apparatus consisting of a hood model/wind tunnel assembly. The velocity field on the symmetry plane was measured with a two-component laser Doppler anemometer. Being under the influence of cross draft, the suction field presents a characteristic capture envelope, which is described by a dividing streamline. The characteristics of the capture envelope were found to be determined by the cross-draft to hood-suction velocity ratio R and the hood-opening aspect ratio AR. The flow characteristics of the hoods with aspect ratios less than unity were dramatically different from those with aspect ratios greater than one. If areas of the hood openings had the same values, the hydraulic-diameter normalized characteristic length scales of the capture zone of the square hood were as same as those of the circular hood. When the diameter of a circular hood was equal to the width of a square hood, the physical dimensions of the capture zones created by these two hoods coincided with each other.

  12. Accessibility: Maximum Mobility and Function.

    ERIC Educational Resources Information Center

    Smyser, Michael

    2003-01-01

    Describes how to design school and university labs to comply with Americans with Disabilities Act (ADA) standards, focusing on counter height for students in wheelchairs; appropriate knee space and sink height in sink areas; ADA-compliant fume hoods; accessible laboratory doors and entryways; and safety concerns (e.g., emergency eyewash stations…

  13. Portable total reflection x-ray fluorescence analysis in the identification of unknown laboratory hazards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Ying, E-mail: liu.ying.48r@st.kyoto-u.ac.jp; Imashuku, Susumu; Sasaki, Nobuharu

    In this study, a portable total reflection x-ray fluorescence (TXRF) spectrometer was used to analyze unknown laboratory hazards that precipitated on exterior surfaces of cooling pipes and fume hood pipes in chemical laboratories. With the aim to examine the accuracy of TXRF analysis for the determination of elemental composition, analytical results were compared with those of wavelength-dispersive x-ray fluorescence spectrometry, scanning electron microscope and energy-dispersive x-ray spectrometry, energy-dispersive x-ray fluorescence spectrometry, inductively coupled plasma atomic emission spectrometry, x-ray diffraction spectrometry (XRD), and x-ray photoelectron spectroscopy (XPS). Detailed comparison of data confirmed that the TXRF method itself was not sufficient tomore » determine all the elements (Z > 11) contained in the samples. In addition, results suggest that XRD should be combined with XPS in order to accurately determine compound composition. This study demonstrates that at least two analytical methods should be used in order to analyze the composition of unknown real samples.« less

  14. Hood: Answers in Action.

    ERIC Educational Resources Information Center

    Hood Coll., Frederick, MD.

    The president of Hood College, a liberal arts college for women located in Frederick, Maryland, considers the challenges confronting American higher education and describes what one college is doing to meet them. A description of Hood College and American higher education is provided. Seven sections focus on the following: (1) matters of equity…

  15. All about Asbestos

    ERIC Educational Resources Information Center

    Roy, Ken

    2005-01-01

    Asbestos has been used in the construction of elementary, middle, and high school ceilings, floor tile adhesives, pipe and structural beam insulations, science laboratory benches, wire gauss on ring stands, fume hood panels, general insulation, and more during the 1950s through early 1970s. Why? Primarily asbestos was selected because of its…

  16. Freshly generated stainless steel welding fume induces greater lung inflammation in rats as compared to aged fume.

    PubMed

    Antonini, J M; Clarke, R W; Krishna Murthy, G G; Sreekanthan, P; Jenkins, N; Eagar, T W; Brain, J D

    1998-09-01

    It has been previously reported that both short- and long-lived reactive oxygen species (ROS) are present on the surface of freshly generated fumes. The objective of this study was to determine if freshly formed welding fume induces greater lung inflammation and injury in rats due to the presence of reactive oxygen species than aged welding fume. Fume was collected during gas metal arc welding using a stainless steel consumable electrode and found to be of respirable size with a mean diameter of 0.77 microm +/- 0.48. Male CD/VAF rats were dosed intratracheally with the welding fume 30 min (fresh) and 1 and 7 days (aged) after fume collection at a dose of 1.0 mg/100 g b wt. Bronchoalveolar lavage (BAL) was performed 24 h post-instillation. Lung injury and inflammation were assessed by measuring the concentration of neutrophils, albumin, lactate dehydrogenase (LDH), and glucosaminidase (GLU) in the recovered BAL fluid. More neutrophils and enhanced GLU activity were observed for the 'fresh' group as compared to both 'aged' groups (P < 0.05). Slight, but not significant, elevations were seen in albumin content and LDH activity for the 'fresh' group as compared to the 'aged' groups. No significant differences were observed for any of the parameters when fume aged for 1 and 7 days were compared. When the 'fresh' and 'aged' fumes (12.5, 25, and 50 microg/ml) were suspended in dichlorofluorescin (15 microM), a probe which becomes fluorescent when oxidized, the concentration-dependent increases in fluorescence were greater for the 'fresh' fume versus the 'aged' fumes. We have demonstrated that freshly generated stainless steel welding fume induces greater lung inflammation than 'aged' fume. This is likely due to a higher concentration of ROS on fresh fume surfaces.

  17. Determination of the internal exposure hazard from plutonium work in an open front hood

    NASA Astrophysics Data System (ADS)

    Olson, Cheryl Lynn

    Work with hazardous substances, such as radioactive material, can be done safely when engineered controls are used to maintain the worker effective dose below the International Commission on Radiological Protection ICRP 60 recommendation of 0.02 Sv/year and reduce the worker exposure to material to as low as reasonably achievable (ALARA). A primary engineered control used at a Los Alamos National Laboratory facility is the open-front hood. An open-front hood, also known as an open-front box, is a laboratory containment box that is fully enclosed except for a 15-cm opening along the front of the box. This research involved collection of the aerosol escaping an open-front hood while PuO2 sample digestion was simulated. Sodium chloride was used as a surrogate to mimic the behavior of PuO2. The NaCl aerosol was binned as a function of median aerodynamic diameter using a Micro-orifice Uniform Deposit Impactor (MOUDI, MSP Corporation, Shoreview, MN) cascade impactor. Using neutron activation analysis (NAA) to measure the mass of material in each of the nine bins of the MOUDI, the mass median diameter of the escaping aerosol was determined. Using the mass median diameter and the total mass of the particle distribution, dose was calculated using ICRP 60 methodology. Experimental conditions mimicked a stationary worker and a worker moving her hands in and out of the open front hood. Measurements were also done in the hood for comparison. The effect of the hands moving in and out of the box was modeled. Information necessary for Computational Fluid Dynamics (CFD) modeling is given, such as volumetric flow rates out of the open front hood and into the experimental room, detailed sketches of the experimental set-up, and energy provided by the hot plate and worker. This research is unique as it measures particle size distribution from routine working conditions. Current research uses tracer gases or describes non-routine conditions. It is important to have results that mimic

  18. Hydrogen Supply System for Small PEM Fuel Cell Stacks

    DTIC Science & Technology

    1997-07-01

    a trivalent metal capable of forming complex hydrides such as Al or B. m is the valence of Z and n is the valence of X For example, let X be chlorine...been taken, the reactor is opened into a fume hood. After the reactor reaches atmospheric pressure, it is re-pressurized with nitrogen and bled again...into the fume hood to remove the remaining vapors before it is opened. After the fumes have dissipated, the endcap is loosened and removed. The spent

  19. Is Robin Hood Alive in Your Classroom?

    ERIC Educational Resources Information Center

    Royer, Sharon E.

    2002-01-01

    Considers whether the tales of Robin Hood should be presented as fact or fiction. Discusses the appropriateness of the tales for use in literature programs. Presents arguments for Robin Hood as fact and arguments for Robin Hood as fiction. Considers different versions of the tale. (SG)

  20. The Effect of Condensing Steam Turbine Exhaust Hood Body Geometry on Exhaust Performance Efficiency

    NASA Astrophysics Data System (ADS)

    Gribin, V. G.; Paramonov, A. N.; Mitrokhova, O. M.

    2018-06-01

    The article presents data from combined numerical and experimental investigations of the effect that the overall dimensions of the exhaust hood of a steam turbine with an underslung condenser has on the aerodynamic losses in the hood. Owing to the properly selected minimum permissible overall dimensions of the exhaust hood, more efficient operation of this turbine component is achieved, better vibration stability of the turbine set shaft line is obtained, and lower costs are required for arranging the steam turbine plant in the turbine building. Experiments have shown that the main overall dimensions of the hood body have a determining effect on the exhaust hood flow path profile and on its aerodynamic performance. Owing to properly selected ratios between the exhaust hood body main sizes without a diffuser, a total loss coefficient equal to approximately unity has been obtained. By using an axial-radial diffuser, the energy loss can be decreased by 30-40% depending on the geometrical parameters and level of velocities in the inlet section of a hood having the optimal overall dimensions. By using the obtained results, it becomes possible to evaluate the overall dimensions necessary for achieving the maximal aerodynamic hood efficiency and, as a consequence, to obtain better technical and economic indicators of the turbine plant as a whole already at the initial stage of its designing. If a need arises to select overall dimensions smaller than their optimal values, the increase of energy loss can be estimated using the presented dependences. The cycle of investigations was carried out on the experimental setups available in the fundamental research laboratory of the Moscow Power Engineering Institute National University's Department of Steam and Gas Turbines with due regard to the operating parameters and similarity criteria.

  1. Parallel In Situ Screening of Remediation Strategies for Improved Decision Making, Remedial Design, and Cost Savings

    DTIC Science & Technology

    2013-02-01

    November 2012 phosphorus, and vitamin B12. Additionally a reductant reacts directly with hexavalent chromium to reduce it to the trivalent state. SRS...being operated under continuous flow conditions in the laboratory. Entire assembly takes up approximately 5 sq. ft. in a fume hood. . 44 Figure 5-3...61 Figure 5-16. Hexavalent Chromium detected in ISMA effluent post in situ incubation

  2. Workplace field testing of the pressure drop of particulate respirators using welding fumes.

    PubMed

    Cho, Hyun-Woo; Yoon, Chung-Sik

    2012-10-01

    In a previous study, we concluded that respirator testing with a sodium chloride aerosol gave a conservative estimate of filter penetration for welding fume aerosols. A rapid increase in the pressure drop (PD) of some respirators was observed as fumes accumulated on the filters. The present study evaluated particulate respirator PD based on workplace field tests. A field PD tester was designed and validated using the TSI 8130 Automatic Filter Tester, designed in compliance with National Institute for Occupational and Safety and Health regulation 42 CFR part 84. Three models (two replaceable dual-type filters and one replaceable single-type filter) were evaluated against CO(2) gas arc welding on mild steel in confined booths in the workplace. Field tests were performed under four airborne concentrations (27.5, 15.4, 7.9, and 2.1 mg m(-3)). The mass concentration was measured by the gravimetric method, and number concentration was monitored using P-Trak (Model 8525, TSI, USA). Additionally, photos and scanning electron microscopy-energy dispersive X-ray spectroscopy were used to visualize and analyze the composition of welding fumes trapped in the filters. The field PD tester showed no significant difference compared with the TSI tester. There was no significant difference in the initial PD between laboratory and field results. The PD increased as a function of fume load on the respirator filters for all tested models. The increasing PD trend differed by models, and PD increased rapidly at high concentrations because greater amount of fumes accumulated on the filters in a given time. The increase in PD as a function of fume load on the filters showed a similar pattern as fume load varied for a particular model, but different patterns were observed for different models. Images and elemental analyses of fumes trapped on the respirator filters showed that most welding fumes were trapped within the first layer, outer web cover, and second layer, in order, while no fumes

  3. Chemical composition and morphology of welding fume particles and grinding dusts.

    PubMed

    Karlsen, J T; Farrants, G; Torgrimsen, T; Reith, A

    1992-05-01

    Elemental composition and morphology of pure manual metal arc (MMA) welding fumes, pure grinding dust, and combined fume/dust air samples were collected and determined separately under semilaboratory conditions. The base material was stainless steel. The purpose of the present study was to create a "synthetic" work situation under semilaboratory conditions by combining one grinding period and two MMA welding periods and comparing these results with results during welding in a workshop. The duty cycles of pure welding and of pure grinding were also observed. A comparison was also made between metal inert gas (MIG) and MMA welding on stainless steel as well as a nickel-rich alloy under regular conditions. The amount of collected material was determined by weighing the membrane filters before and after exposure, and the element contents were determined by atomic spectroscopy. Other transmission electron microscopy (TEM) filters were used for TEM and computer-image analysis, in which the amount of collected material and its morphological characteristics were observed. The arcing time and the consumption of filler material were estimated for different kinds of electrodes. Chemical analysis showed that the contents of manganese and total chromium were lower in grinding dust than in welding fumes. The contents of hexavalent chromium, Cr(VI), in grinding dust were undetectable. Samples collected in welding shops where concomitant grinding was performed contained about 30% less Cr(VI) than those collected under laboratory conditions during welding only. The sizes and shapes of the particles depend on the welding process and distance of collection from the plume of the fume. To compare laboratory experiments with regular welding situations, the experiment must resemble industrial welding.(ABSTRACT TRUNCATED AT 250 WORDS)

  4. Corrosion-Mitigating, Bondable, Fluorinated Barrier Coating for Anodized Magnesium

    DTIC Science & Technology

    2016-05-01

    transport the precursor vapor throughout the study was set at 9,500 sccm. The setup also incorporated a 38- × 54- × 0.6-cm stainless steel moveable...evaporated and that silane crosslinking had occurred, samples were allowed to sit uncovered in a fume hood for 1 h prior to electrochemical...measurement, contact-angle measurement, or plasma treatment. Samples were stored in a fume hood for approximately 24 h before applying an epoxy topcoat

  5. Process Hood Stand Support Steel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    VAN KATWIJK, C.

    2000-04-03

    This package is written to comply with EN-6-035-00 for upgrade dedication of commercial grade items (CGI). The SNF-5953 CGI package provides the Technical evaluation to identify the critical characteristics and the acceptance criteria associated with the safety function of the Hood Stand Support Steel. Completion of the technical and quality requirements identified in the dedication package will provide enough data to be reasonably assured that CGI Hood Stand Support Steel will perform its SC function.

  6. Experimental investigation on high performance RC column with manufactured sand and silica fume

    NASA Astrophysics Data System (ADS)

    Shanmuga Priya, T.

    2017-11-01

    In recent years, the use High Performance Concrete (HPC) has increased in construction industry. The ingredients of HPC depend on the availability and characteristics of suitable alternative materials. Those alternative materials are silica fume and manufactured sand, a by products from ferro silicon and quarry industries respectively. HPC made with silica fume as partial replacement of cement and manufactured sand as replacement of natural sand is considered as sustainable high performance concrete. In this present study the concrete was designed to get target strength of 60 MPa as per guide lines given by ACI 211- 4R (2008). The laboratory study was carried out experimentally to analyse the axial behavior of reinforced cement HPC column of size 100×100×1000mm and square in cross section. 10% of silica fume was preferred over ordinary portland cement. The natural sand was replaced by 0, 20, 40, 60, 80 and 100% with Manufactured Sand (M-Sand). In this investigation, totally 6 column specimens were cast for mixes M1 to M6 and were tested in 1000kN loading frame at 28 days. From this, Load-Mid height deflection curves were drawn and compared. Maximum ultimate load carrying capacity and the least deflection is obtained for the mix prepared by partial replacement of cement with 10% silica fume & natural sand by 100% M-Sand. The fine, amorphous and pozzalonic nature of silica fume and fine mineral particles in M- Sand increased the stiffness of HPC column. The test results revealed that HPC can be produced by using M-Sand with silica fume.

  7. Flow Characteristics and Robustness of an Inclined Quad-vortex Range Hood

    PubMed Central

    CHEN, Jia-Kun; HUANG, Rong Fung

    2014-01-01

    A novel design of range hood, which was termed the inclined quad-vortex (IQV) range hood, was examined for its flow and containment leakage characteristics under the influence of a plate sweeping across the hood face. A flow visualization technique was used to unveil the flow behavior. Three characteristic flow modes were observed: convex, straight, and concave modes. A tracer gas detection method using sulfur hexafluoride (SF6) was employed to measure the containment leakage levels. The results were compared with the test data reported previously in the literature for a conventional range hood and an inclined air curtain (IAC) range hood. The leakage SF6 concentration of the IQV range hood under the influence of the plate sweeping was 0.039 ppm at a suction flow rate of 9.4 m3/min. The leakage concentration of the conventional range hood was 0.768 ppm at a suction flow rate of 15.0 m3/min. For the IAC range hood, the leakage concentration was 0.326 ppm at a suction flow rate of 10.9 m3/min. The IQV range hood presented a significantly lower leakage level at a smaller suction flow rate than the conventional and IAC range hoods due to its aerodynamic design for flow behavior. PMID:24583513

  8. 42 CFR 84.1146 - Lead fume test for dust, fume, and mist respirators; minimum requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Lead fume test for dust, fume, and mist respirators; minimum requirements. 84.1146 Section 84.1146 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  9. 42 CFR 84.1146 - Lead fume test for dust, fume, and mist respirators; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Lead fume test for dust, fume, and mist respirators; minimum requirements. 84.1146 Section 84.1146 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  10. 42 CFR 84.1146 - Lead fume test for dust, fume, and mist respirators; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Lead fume test for dust, fume, and mist respirators; minimum requirements. 84.1146 Section 84.1146 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  11. 42 CFR 84.1146 - Lead fume test for dust, fume, and mist respirators; minimum requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Lead fume test for dust, fume, and mist respirators; minimum requirements. 84.1146 Section 84.1146 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  12. 42 CFR 84.1146 - Lead fume test for dust, fume, and mist respirators; minimum requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Lead fume test for dust, fume, and mist respirators; minimum requirements. 84.1146 Section 84.1146 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  13. Fort Hood Army Internal Review Team: Final Report

    DTIC Science & Technology

    2010-08-04

    Report Date l August 4, 2010 Protecting our Army community at home & abroad Army Internal Review Team : Final Report Report Documentation Page Form...DATES COVERED 00-00-2010 to 00-00-2010 4. TITLE AND SUBTITLE Fort Hood Army Internal Review Team : Final Report 5a. CONTRACT NUMBER 5b. GRANT...Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 FoRt Hood Army Internal Review team : Final Report August 4, 2010 1 FoRt Hood Army

  14. A Novel Method for Assessing Respiratory Deposition of Welding Fume Nanoparticles

    PubMed Central

    Cena, L. G.; Keane, M. J.; Chisholm, W. P.; Stone, S.; Harper, M.; Chen, B. T.

    2016-01-01

    Welders are exposed to high concentrations of nanoparticles. Compared to larger particles, nanoparticles have been associated with more toxic effects at the cellular level, including the generation of more reactive oxygen species activity. Current methods for welding-fume aerosol exposures do not differentiate between the nano-fraction and the larger particles. The objectives of this work are to establish a method to estimate the respiratory deposition of the nano-fraction of selected metals in welding fumes and test this method in a laboratory setting. Manganese (Mn), Nickel (Ni), Chromium (Cr), and hexavalent chromium (Cr(VI)) are commonly found in welding fume aerosols and have been linked with severe adverse health outcomes. Inductively coupled plasma mass spectrometry (ICP-MS) and ion chromatography (IC) were evaluated as methods for analyzing the content of Mn, Ni, Cr, and Cr(VI) nanoparticles in welding fumes collected with nanoparticle respiratory deposition (NRD) samplers. NRD samplers collect nanoparticles at deposition efficiencies that closely resemble physiological deposition in the respiratory tract. The limits of detection (LODs) and quantitation (LOQs) for ICP-MS and IC were determined analytically. Mild and stainless steel welding fumes generated with a robotic welder were collected with NRD samplers inside a chamber. LODs (LOQs) for Mn, Ni, Cr, and Cr(VI) were 1.3 μg (4.43 μg), 0.4 μg (1.14 μg), 1.1 μg (3.33 μg), and 0.4 μg (1.42 μg), respectively. Recovery of spiked samples and certified welding fume reference material was greater than 95%. When testing the method, the average percentage of total mass concentrations collected by the NRD samplers was ~30% for Mn, ~50% for Cr, and ~60% for Ni, indicating that a large fraction of the metals may lie in the nanoparticle fraction. This knowledge is critical to the development of toxicological studies aimed at finding links between exposure to welding fume nanoparticles and adverse health

  15. A novel method for assessing respiratory deposition of welding fume nanoparticles.

    PubMed

    Cena, L G; Keane, M J; Chisholm, W P; Stone, S; Harper, M; Chen, B T

    2014-01-01

    Welders are exposed to high concentrations of nanoparticles. Compared to larger particles, nanoparticles have been associated with more toxic effects at the cellular level, including the generation of more reactive oxygen species activity. Current methods for welding-fume aerosol exposures do not differentiate between the nano-fraction and the larger particles. The objectives of this work are to establish a method to estimate the respiratory deposition of the nano-fraction of selected metals in welding fumes and test this method in a laboratory setting. Manganese (Mn), Nickel (Ni), Chromium (Cr), and hexavalent chromium (Cr(VI)) are commonly found in welding fume aerosols and have been linked with severe adverse health outcomes. Inductively coupled plasma mass spectrometry (ICP-MS) and ion chromatography (IC) were evaluated as methods for analyzing the content of Mn, Ni, Cr, and Cr(VI) nanoparticles in welding fumes collected with nanoparticle respiratory deposition (NRD) samplers. NRD samplers collect nanoparticles at deposition efficiencies that closely resemble physiological deposition in the respiratory tract. The limits of detection (LODs) and quantitation (LOQs) for ICP-MS and IC were determined analytically. Mild and stainless steel welding fumes generated with a robotic welder were collected with NRD samplers inside a chamber. LODs (LOQs) for Mn, Ni, Cr, and Cr(VI) were 1.3 μg (4.43 μg), 0.4 μg (1.14 μg), 1.1 μg (3.33 μg), and 0.4 μg (1.42 μg), respectively. Recovery of spiked samples and certified welding fume reference material was greater than 95%. When testing the method, the average percentage of total mass concentrations collected by the NRD samplers was ~30% for Mn, ~50% for Cr, and ~60% for Ni, indicating that a large fraction of the metals may lie in the nanoparticle fraction. This knowledge is critical to the development of toxicological studies aimed at finding links between exposure to welding fume nanoparticles and adverse health

  16. Humboldt Open Ocean Disposal Site (HOODS) Survey Work 2014

    EPA Pesticide Factsheets

    The Humboldt Open Ocean Disposal Site (HOODS) is a dredged material disposal site located 3 nautical miles (nm) offshore of Humboldt Bay in Northern California. HOODS was permanently designated by EPA Region 9 in 1995, and has been actively used for dredged material disposal operations since then. The HOODS has received higher volumes of dredged material than predicted since its designation in 1995, mainly from USACE construction and maintenance dredging.

  17. The three dimensional distribution of chromium and nickel alloy welding fumes.

    PubMed

    Mori, T; Matsuda, A; Akashi, S; Ogata, M; Takeoka, K; Yoshinaka, M

    1991-08-01

    In the present study, the fumes generated from manual metal arc (MMA) and submerged metal arc (SMA) welding of low temperature service steel, and the chromium and nickel percentages in these fumes, were measured at various horizontal distances and vertical heights from the arc in order to obtain a three dimensional distribution. The MMA welding fume concentrations were significantly higher than the SMA welding fume concentrations. The highest fume concentration on the horizontal was shown in the fumes collected directly above the arc. The fume concentration vertically was highest at 50 cm height and reduced by half at 150 cm height. The fume concentration at 250 cm height was scarcely different from that at 150 cm height. The distribution of the chromium concentration vertically was analogous to the fume concentration, and a statistically significant difference in the chromium percentages was not found at the different heights. The nickel concentrations were not statistically significant within the welding processes, but the nickel percentages in the SMA welding fumes were statistically higher than in the MMA welding fumes. The highest nickel concentration on the horizontal was found in the fumes collected directly above the arc. The highest nickel concentration vertically showed in the fume samples collected at 50 cm height, but the greater the height the larger the nickel percentage in the fumes.

  18. Neoprene wet-suit hood affects low-frequency underwater hearing thresholds.

    PubMed

    Fothergill, David M; Sims, John R; Curley, Michael D

    2004-05-01

    Psychophysical measures of wet-suit hood sound attenuation are needed to provide the diving community with guidance on protection from underwater sound. Underwater hearing thresholds were obtained from 15 male and 5 female recreational divers with and without a 3-mm thick wet-suit hood. Dives were conducted at a depth of 1 m in a large quiet anechoic pool. Thresholds were determined using a two-interval forced-choice procedure with a 0.71 probability of positive response at convergence. A 1-s pure tone was presented with a 20-ms rise and fall time at 100, 200, 250, 300, 400, and 500 Hz. Without a wet-suit hood, mean thresholds decreased from 99 dB re 1 microPa at 100 Hz to 85 dB at 500 Hz. Thresholds were statistically similar at 100 to 300 Hz with and without the wet-suit hood, but were significantly increased at 400 and 500 Hz with the hood (p < 0.001). In conclusion, at shallow depths, a 3-mm neoprene wet-suit hood attenuates underwater sound by approximately 10 dB for frequencies between 400 Hz and 500 Hz. At frequencies below 400 Hz, a 3-mm neoprene wet-suit hood offers no sound protection.

  19. Improving flow patterns and spillage characteristics of a box-type commercial kitchen hood.

    PubMed

    Huang, Rong Fung; Chen, Jia-Kun; Han, Meng-Ji; Priyambodo, Yusuf

    2014-01-01

    A conventional box-type commercial kitchen hood and its improved version (termed the "IQV commercial kitchen hood") were studied using the laser-assisted smoke flow visualization technique and tracer-gas (sulfur hexafluoride) detection methods. The laser-assisted smoke flow visualization technique qualitatively revealed the flow field of the hood and the areas apt for leakages of hood containment. The tracer-gas concentration detection method measured the quantitative leakage levels of the hood containment. The oil mists that were generated in the conventional box-type commercial kitchen hood leaked significantly into the environment from the areas near the front edges of ceiling and side walls. Around these areas, the boundary-layer separation occurred, inducing highly unsteady and turbulent recirculating flow, and leading to spillages of hood containment due to inappropriate aerodynamic design at the front edges of the ceiling and side walls. The tracer-gas concentration measurements on the conventional box-type commercial kitchen hood showed that the sulfur hexafluoride concentrations detected at the hood face attained very large values on an order of magnitude about 10(3)-10(4) ppb. By combining the backward-offset narrow suction slot, deflection plates, and quarter-circular arcs at the hood entrance, the IQV commercial kitchen hood presented a flow field containing four backward-inclined cyclone flow structures. The oil mists generated by cooking were coherently confined in these upward-rising cyclone flow structures and finally exhausted through the narrow suction slot. The tracer-gas concentration measurements on the IQV commercial kitchen hood showed that the order of magnitude of the sulfur hexafluoride concentrations detected at the hood face is negligibly small--only about 10(0) ppb across the whole hood face.

  20. Development of an inhalation system of high melting point metal fumes and its use for exposure of rats to chromium and nickel fumes.

    PubMed

    Serita, F; Homma, K; Fukuda, K; Sawatari, K; Suzuki, Y; Toya, T

    1990-01-01

    An experimental inhalation system was developed for fumes generated from powders of high melting point metals such as chromium, nickel, manganese and iron. The system consisted of a plasma flame metal sprayer as a fume generator, a granular bed type fume collector, a fluidized bed aerosol generator, an exposure and a control chamber of a horizontal-flow type and inhalant monitoring and controlling units. Performance of the chambers was ensured by a distribution test using flyash as a test aerosol. Using this system, rats were exposed to chromium fumes for one week or to nickel fumes for two months. The exposure concentrations of the chromium and nickel fumes were 1.85 +/- 0.55 mg/m3 and 0.51 +/- 0.15 mg/m3 (mean +/- SD), near the target levels of 2 mg/m3 and 0.5 mg/m3, respectively. The mass median aerodynamic diameter and the geometric standard deviation of the chromium fumes were 2.1 microns and 2.00, respectively. Those of the nickel fumes were 3.7 microns and 1.74, respectively. Species analysis of these fume particles revealed that 26.4% of the total chromium was hexavalent and the residue was trivalent and that 1-3% of the total nickel was nickel(III) and the residue was nickel(II). Inhaled-metal concentrations in the lungs showed steady increases with the exposure periods and were within the normal range of variation. On the basis of these results, it is concluded that this system is useful for long-term inhalation experiments using high melting point metal fumes.

  1. Fume generation rates for stainless steel, nickel and aluminum alloys

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Castner, H.R.

    1996-12-01

    This paper describes a study of the effects of pulsed welding current on fume produced during gas metal arc welding (GMAW) of stainless steel, nickel, and aluminum alloys. This is an extension of earlier studies of mild steel electrode wire. Reduction of welding fume is important because steady current GMAW of stainless steels and nickel alloys may produce fume that exceeds recommended worker exposure limits for some of the fume constituents. Fume generation from aluminum alloy ER5356 was studied because steady current welding with this alloy produces much higher fume generation rates than ER4043 alloy electrode wire. This work showsmore » that pulsed current can reduce GMAW fume generation rates for Er308L, ER310, and ER312 stainless steel, ERNiCr-3 nickel alloy, and ER5356 aluminum-magnesium alloy electrode wires.« less

  2. Environmental Consequences of Nanotechnologies: Nanoparticle Dispersion in Aqueous Media: SOP-T-1

    DTIC Science & Technology

    2015-02-01

    containing ice • Bath sonicator • Weighing dish (aluminum) • Stainless steel spatula • Analytical balance • Lab jack for lifting sample • Volumetric...balance and an aluminum dish, weigh an adequate mass of dry powder under a fume hood to achieve the desired concentration into ultrapure water (<T>, <R...0.025 0.5 0.05 1 0.5 10 1 20 2. Add ultra-pure water in a glass beaker with NP powder to /flask under fume hood (<T>, <R>). 3. Degas the bath

  3. Cognitive Style Mapping at Mt. Hood Community College.

    ERIC Educational Resources Information Center

    Keyser, John S.

    1980-01-01

    Describes Mount Hood Community College's experiences using the Modified Hill Model for Cognitive Style Mapping (CSM). Enumerates the nine dimensions of cognitive style assessed by the model. Discusses the value and limitations of CSM, five major checks on the validity of the model, and Mount Hood faculty's involvement with CSM. (AYC)

  4. A Methodology for the Geometric Standardization of Vehicle Hoods to Compare Real-World Pedestrian Crashes

    PubMed Central

    Koetje, Bethany D.; Grabowski, Jurek G.

    2008-01-01

    This paper describes a standardization method that allows injury researchers to directly compare pedestrian hood contact points across a variety of hood sizes and geometries. To standardize hood contact locations a new coordinate system was created at the geometric center of the hood. Standardizing hood contact locations was done by turning each coordinate location into a ratio of the entire length or width of the hood. The standardized pedestrian contact locations could then be compared for various hood sizes. The standardized hood was divided into a three-by-three grid to aggregate contact points into hood regions. Data was obtained from the National Highway Traffic Safety Administration’s Pedestrian Crash Data Study from 1994 to 1998. To understand injury severity with respect to pedestrian hood contact location, the injuries were narrowed to the single most severe Abreviated Injury Scale injury to the pedestrian and hood location at which that injury was sustained. Of the 97 pedestrian/vehicle cases, pedestrians received 270 injuries from 141 unique hood contact locations. After standardization, 36%, 28%, 36% of all contact points were located on the left, center and right side of the hood respectively. Vertically, 26%, 45%, 28% of contacts occurred at the front, middle, and rear regions of the hood respectively. The middle passenger side of the hood contained the most number of AIS 3+ injuries. By using real-world crash data, engineers can make evidence based decisions to decease the severity of pedestrian injuries. PMID:19026236

  5. Identification of sulfur fumed Pinelliae Rhizoma using an electronic nose

    PubMed Central

    Zhou, Xia; Wan, Jun; Chu, Liang; Liu, Wengang; Jing, Yafeng; Wu, Chunjie

    2014-01-01

    Background: Pinelliae Rhizoma is a commonly used Chinese herb which will change brown during the natural drying process. However, sulfur fumed Pinelliae Rhizoma will get a better appearance than naturally dried one. Sulfur fumed Pinelliae Rhizoma is potentially toxical due to sulfur dioxide and sulfites formed during the fuming procedures. The odor components in sulfur fumed Pinelliae Rhizoma is complex. At present, there is no analytical method available to determine sulfur fumed Pinelliae Rhizoma simply and rapidly. To ensure medication safety, it is highly desirable to have an effective and simple method to identify sulfur fumed Pinelliae Rhizoma. Materials and Methods: This paper presents a novel approach using an electronic nose based on metal oxide sensors to identify whether Pinelliae Rhizoma was fumed with sulfur, and to predict the fuming degree of Pinelliae Rhizoma. Multivariate statistical methods such as principal components analysis (PCA), discriminant factorial analysis (DFA) and partial least squares (PLS) were used for data analyzing and identification. The use of the electronic nose to discriminate between different fuming degrees Pinelliae Rhizoma and naturally dried Pinelliae Rhizoma was demonstrated. Results: The electronic nose was also successfully applied to identify unknown samples including sulfur fumed samples and naturally dried samples, high recognition value was obtained. Quantitative analysis of fuming degree of Pinelliae Rhizoma was also demonstrated. The method developed is simple and fast, which provides a new quality control method of Chinese herbs from the aspect of odor. Conclusion: It has shown that this electronic nose based metal oxide sensor is sensitive to sulfur and sulfides. We suggest that it can serve as a supportive method to detect residual sulfur and sulfides. PMID:24914293

  6. Effects on the efficiency of activated carbon on exposure to welding fumes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghosh, D.

    1995-02-01

    It is the intention of this paper to document that certain types of welding fumes have little or no effect on the effectiveness of the carbon filter air filtration efficiency when directly exposed to a controlled amount of welding fumes for a short-term period. The welding processes studied were restricted to shielded metal arc welding (SMAW), flux cored arc welding (FCAW), gas tungsten arc welding (GTAW) and gas metal arc welding (GMAW) processes. Contrary to the SMAW and FCAW processes, the GTAW (or TIG) and the GMAW (or MIG) welding processes do not require the use of flux as partmore » of the overall process. Credit was taken for these processes occurring in inert gas environments and producing minimal amount of smoke. It was concluded that a study involving the SMAW process would also envelop the effects of the TIG and MIG welding processes. The quantity of welding fumes generated during the arc welding process is a function of the particular process, the size and type of electrode, welding machine amperage, and operator proficiency. For this study, the amount of welding for specific testing was equated to the amount of welding normally conducted during plant unit outages. Different welding electrodes were also evaluated, and the subsequent testing was limited to an E7018 electrode which was judged to be representative of all carbon and stainless steel electrodes commonly used at the site. The effect of welding fumes on activated charcoal was tested using a filtration unit complete with prefilters, upstream and downstream high efficiency particulate air (HEPA) filters, and a carbon adsorber section. The complete system was field tested in accordance with ANSI N510 standards prior to exposing the filters and the adsorber bed to welding fumes. The carbon samples were tested at an established laboratory using ASTM D3803-1989 standards.« less

  7. [Analysis on oil fume particles in catering industry cooking emission].

    PubMed

    Tan, De-Sheng; Kuang, Yuan-Cheng; Liu, Xin; Dai, Fei-Hong

    2012-06-01

    By measuring the particulate matter of oil fume which is over 10 microm or below 10 microm separately and using microradiography and Electrical Low Pressure Impactor (ELPI), it is found out the distributing characteristic of oil fume particles in catering industry cooking emission. The result shows that the diameter of the oil fume particles which was sedimentated in the kitchen is between 10-400 microm, the concentration peak value is between 10-100 microm. The diameter of oil fume aerosol is mostly smaller than 1 microm, while the concentration peak value is between 0.063-0.109 microm. In addition, the mass concentration peak value is between 6.560-9.990 microm. Through the analysis to the physical characteristics of oil fume from catering industry cooking emissions, the eigenvalue of the oil fume has been found and the feature matter for monitoring the oil fume has been discovered to provide a reasonable standard for controlling and monitoring the catering industry cooking emission.

  8. Aerodynamics and performance verifications of test methods for laboratory fume cupboards.

    PubMed

    Tseng, Li-Ching; Huang, Rong Fung; Chen, Chih-Chieh; Chang, Cheng-Ping

    2007-03-01

    The laser-light-sheet-assisted smoke flow visualization technique is performed on a full-size, transparent, commercial grade chemical fume cupboard to diagnose the flow characteristics and to verify the validity of several current containment test methods. The visualized flow patterns identify the recirculation areas that would inevitably exist in the conventional fume cupboards because of the fundamental configurations and structures. The large-scale vortex structures exist around the side walls, the doorsill of the cupboard and in the vicinity of the near-wake region of the manikin. The identified recirculation areas are taken as the 'dangerous' regions where the risk of turbulent dispersion of contaminants may be high. Several existing tracer gas containment test methods (BS 7258:1994, prEN 14175-3:2003 and ANSI/ASHRAE 110:1995) are conducted to verify the effectiveness of these methods in detecting the contaminant leakage. By comparing the results of the flow visualization and the tracer gas tests, it is found that the local recirculation regions are more prone to contaminant leakage because of the complex interaction between the shear layers and the smoke movement through the mechanism of turbulent dispersion. From the point of view of aerodynamics, the present study verifies that the methodology of the prEN 14175-3:2003 protocol can produce more reliable and consistent results because it is based on the region-by-region measurement and encompasses the most area of the entire recirculation zone of the cupboard. A modified test method combined with the region-by-region approach at the presence of the manikin shows substantially different results of the containment. A better performance test method which can describe an operator's exposure and the correlation between flow characteristics and the contaminant leakage properties is therefore suggested.

  9. Gas metal arc welding fume generation using pulsed current

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Castner, H.R.

    1994-12-31

    This paper describes a study of the effects of pulsed welding current on the amount of welding fume and ozone produced during gas metal arc welding (GMAW) using a range of welding procedures and pulse parameters. The results reported in this paper show that pulsed current can reduce GMAW fumes compared to steady current. This research also shows that welding parameters need to be properly controlled if pulsed current is to be used to reduce welding fumes. Fume and ozone generation rates were measured during this study for GMAW of mild steel using copper-coated ER70S-3 electrode wire and 95%Ar-5%CO{sub 2}more » and 85%Ar-15%CO{sub 2} shielding gases. Welds were made with both steady current and pulsed current over a wide range of welding parameters. Fume generation rates for steady current were found to be typically between 0.2 g/min and 0.8 g/min which agrees with other researchers. No significant difference was found in the chemical composition of welding fumes from pulsed current compared to the composition of fumes generated by steady current. New technology that can reduce arc welding fumes is of significant interest to a wide range of companies that use arc welding processes and this research should assist these users in evaluating the potential for the application of this technology to their own operations.« less

  10. Hood River Passive House, Hood River, Oregon (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    2014-02-01

    The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to "reduce home energy use by 30%-50%" (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift Housemore » and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.« less

  11. Flow characteristics of an inclined air-curtain range hood in a draft

    PubMed Central

    CHEN, Jia-Kun

    2015-01-01

    The inclined air-curtain technology was applied to build an inclined air-curtain range hood. A draft generator was applied to affect the inclined air-curtain range hood in three directions: lateral (θ=0°), oblique (θ=45°), and front (θ=90°). The three suction flow rates provided by the inclined air-curtain range hood were 10.1, 10.9, and 12.6 m3/min. The laser-assisted flow visualization technique and the tracer-gas test method were used to investigate the performance of the range hood under the influence of a draft. The results show that the inclined air-curtain range hood has a strong ability to resist the negative effect of a front draft until the draft velocity is greater than 0.5 m/s. The oblique draft affected the containment ability of the inclined air-curtain range hood when the draft velocity was larger than 0.3 m/s. When the lateral draft effect was applied, the capture efficiency of the inclined air-curtain range hood decreased quickly in the draft velocity from 0.2 m/s to 0.3 m/s. However, the capture efficiencies of the inclined air-curtain range hood under the influence of the front draft were higher than those under the influence of the oblique draft from 0.3 m/s to 0.5 m/s. PMID:25810445

  12. Flow characteristics of an inclined air-curtain range hood in a draft.

    PubMed

    Chen, Jia-Kun

    2015-01-01

    The inclined air-curtain technology was applied to build an inclined air-curtain range hood. A draft generator was applied to affect the inclined air-curtain range hood in three directions: lateral (θ=0°), oblique (θ=45°), and front (θ=90°). The three suction flow rates provided by the inclined air-curtain range hood were 10.1, 10.9, and 12.6 m(3)/min. The laser-assisted flow visualization technique and the tracer-gas test method were used to investigate the performance of the range hood under the influence of a draft. The results show that the inclined air-curtain range hood has a strong ability to resist the negative effect of a front draft until the draft velocity is greater than 0.5 m/s. The oblique draft affected the containment ability of the inclined air-curtain range hood when the draft velocity was larger than 0.3 m/s. When the lateral draft effect was applied, the capture efficiency of the inclined air-curtain range hood decreased quickly in the draft velocity from 0.2 m/s to 0.3 m/s. However, the capture efficiencies of the inclined air-curtain range hood under the influence of the front draft were higher than those under the influence of the oblique draft from 0.3 m/s to 0.5 m/s.

  13. Effect of stainless steel manual metal arc welding fume on free radical production, DNA damage, and apoptosis induction.

    PubMed

    Antonini, James M; Leonard, Stephen S; Roberts, Jenny R; Solano-Lopez, Claudia; Young, Shih-Houng; Shi, Xianglin; Taylor, Michael D

    2005-11-01

    Questions exist concerning the potential carcinogenic effects after welding fume exposure. Welding processes that use stainless steel (SS) materials can produce fumes that may contain metals (e.g., Cr, Ni) known to be carcinogenic to humans. The objective was to determine the effect of in vitro and in vivo welding fume treatment on free radical generation, DNA damage, cytotoxicity and apoptosis induction, all factors possibly involved with the pathogenesis of lung cancer. SS welding fume was collected during manual metal arc welding (MMA). Elemental analysis indicated that the MMA-SS sample was highly soluble in water, and a majority (87%) of the soluble metal was Cr. Using electron spin resonance (ESR), the SS welding fume had the ability to produce the biologically reactive hydroxyl radical (*OH), likely as a result of the reduction of Cr(VI) to Cr(V). In vitro treatment with the MMA-SS sample caused a concentration-dependent increase in DNA damage and lung macrophage death. In addition, a time-dependent increase in the number of apoptotic cells in lung tissue was observed after in vivo treatment with the welding fume. In summary, a soluble MMA-SS welding fume was found to generate reactive oxygen species and cause DNA damage, lung macrophage cytotoxicity and in vivo lung cell apoptosis. These responses have been shown to be involved in various toxicological and carcinogenic processes. The effects observed appear to be related to the soluble component of the MMA-SS sample that is predominately Cr. A more comprehensive in vivo animal study is ongoing in the laboratory that is continuing these experiments to try to elucidate the potential mechanisms that may be involved with welding fume-induced lung disease.

  14. Pattern of deposition of stainless steel welding fume particles inhaled into the respiratory systems of Sprague-Dawley rats exposed to a novel welding fume generating system.

    PubMed

    Yu, I J; Kim, K J; Chang, H K; Song, K S; Han, K T; Han, J H; Maeng, S H; Chung, Y H; Park, S H; Chung, K H; Han, J S; Chung, H K

    2000-07-27

    In order to investigate occupational diseases related to welding fume exposure, such as nasal septum perforation, pneumoconiosis and manganese intoxication, we built a welding fume exposure system that included a welding fume generator, exposure chamber and fume collector. The fume concentrations in the exposure chamber were monitored every 15 min during a 2-h exposure. Fume (mg/m(3)) concentrations of major metals, including Fe, Mn, Cr, and Ni were found to be consistently maintained. An acute inhalation toxicity study was conducted by exposing male Sprague-Dawley rats to the welding fumes generated in this apparatus by stainless steel arc welding. The rats were exposed in the inhalation chamber to a welding fume with a concentration of 62 mg/m(3) total suspended particulates for 4 h. Animals were sacrificed at 4 h and at 1, 3, 7, 10, and 14 days after exposure. Histopathological examinations were conducted on the animals' upper respiratory tracts, including the nasal pathway and the conducting airway, and on the gas exchange region including the alveolar ducts, alveolar sacs, and alveoli. Diameters of fume particles varied from 0.02 to 0.81 microm and were distributed log normally, with a mean diameter of 0.1 microm and geometric standard deviation of 1.42. Rats exposed to the welding fume for 4 h did not show any significant respiratory system toxicity. The mean particle diameter of 0.1 microm resulted in little adsorption of the welding fume particles in the upper respiratory tract. Particle adsorption took place principally in the lower respiratory tracts, including bronchioles, alveolar ducts, alveolar sacs, and alveoli.

  15. Diesel exhaust, diesel fumes, and laryngeal cancer.

    PubMed

    Muscat, J E; Wynder, E L

    1995-03-01

    A hospital-based, case-control study of 235 male patients with laryngeal cancer and 205 male control patients was conducted to determine the effects of exposure to diesel engine exhaust and diesel fumes and the risk of laryngeal cancer. All patients were interviewed directly in the hospital with a standardized questionnaire that gathered information on smoking habits, alcohol consumption, employment history, and occupational exposures. Occupations that involve substantial exposure to diesel engine exhaust include mainly truck drivers, as well as mine workers, firefighters, and railroad workers. The odds ratio for laryngeal cancer associated with these occupations was 0.96 (95% confidence interval, 0.5 to 1.8). The odds ratio for self-reported exposure to diesel exhaust was 1.47 (95% confidence interval, 0.5 to 4.1). An elevated risk was found for self-reported exposure to diesel fumes (odds ratio, 6.4; 95% confidence interval, 1.8 to 22.6). No association was observed between jobs that entail exposure to diesel fumes, such as automobile mechanics, and the risk of laryngeal cancer. These results show that diesel engine exhaust is unrelated to laryngeal cancer risk. The different findings for self-reported diesel fumes and occupations that involve exposure to diesel fumes could reflect a recall bias.

  16. Bronchial reactions to exposure to welding fumes.

    PubMed

    Contreras, G R; Chan-Yeung, M

    1997-11-01

    To study the airway response and its mechanism to welding fumes in six welders with respiratory symptoms. Methacholine and welding challenge tests were carried out. The concentration of welding fumes during the exposure test was measured. On two subjects who developed bronchoconstricition to welding challenge, additional tests were carried out including prick, patch, and inhalation challenges with metal salt solutions. Three subjects developed immediate bronchial reaction to exposure to welding fume; one to mild steel and stainless steel welding, another to mild steel and galvanised welding, and one only to galvanised welding. They all had a moderate to pronounced degree of non-specific bronchial hyperresponsiveness. The concentration of fumes during welding tests, particularly to galvanised welding, was high. An inhalation challenge test with zinc chloride salt solution in two subjects who reacted to galvanised welding was negative. Prick and patch tests with zinc chloride were also negative. The airway response to welding in these subjects is non-specific and is due to irritation rather than to sensitisation.

  17. CHARACTERISTICS OF RANGE HOODS IN CALIFORNIA HOMES DATA COLLECTED FROM A REAL ESTATE WEB SITE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klug, Victoria; Singer, Brett; Bedrosian, Tod

    2011-09-02

    Venting range hoods are important residential ventilation components that remove pollutants generated by cooking activities and natural gas cooking burners. To address the lack of data on range hood installations in California, we conducted a survey by examining photographs of homes for sale or rent listed on a popular real estate web site. The survey was conducted in November 2010 and April–May 2011. Posted photos of the homes were reviewed to determine if a hood was installed, the type of hood, and two installation details that can impact performance, namely the height above the cooktop and the degree to whichmore » the hood covers the cooktop burners. We additionally collected information about the homes, including asking price for purchase or rent, type of building (e.g. detached house, townhouse or apartment), building age, floor area, and cooktop fuel type. Listings were first sampled to focus on homes built since 2005, then randomly sampled to include varied prices and locations around the state. Data were obtained for 1002 homes built between 1865 and 2011 (median year built 1989). Homes for sale varied in asking price from $16,000 to $16,500,000 (median $353,000) and homes for rent varied from $500 to $25,000 (median $2125) per month. Approximately 74% of the sample had natural gas cooktops. In this sample, natural gas cooktops were more prevalent in more expensive homes than in less expensive homes. Across the entire sample, 7.4 % appeared to have no hood installed, 33% had a short hood, 13% had a deep hood and 47% had a microwave over the range. The percentage of these hoods that vent to the outdoors could not be determined. Hood type was related to coverage of the cooktop. For deep hoods, 76% appeared to cover most or all of the cooktop burners. For short hoods, 70% covered about three quarters of the cooktop. And for microwaves the vast majority (96%) covered the back burners but not the front burners. Hood type was also correlated with asking

  18. The Topology Optimization Design Research for Aluminum Inner Panel of Automobile Engine Hood

    NASA Astrophysics Data System (ADS)

    Li, Minhao; Hu, Dongqing; Liu, Xiangzheng; Yuan, Huanquan

    2017-11-01

    This article discusses the topology optimization methods for automobile engine hood design. The aluminum inner panel of engine hood and mucilage glue regions are set as design areas, and the static performances of engine hood included modal frequency, lateral stiffness, torsional stiffness and indentation stiffness are set as the optimization objectives. The topology optimization results about different objective functions are contrasted for analysis. And based on the reasonable topology optimization result, a suited automobile engine hood designs are raised to further study. Finally, an automobile engine hood that good at all of static performances is designed, and a favorable topology optimization method is put forward for discussion.

  19. 29 CFR 1917.152 - Welding, cutting and heating (hot work) 12 (See also § 1917.2, definition of Hazardous cargo...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... reflective surfaces. (iv) Inert-gas metal-arc welding on stainless steel shall not be performed unless..., fumes and smoke below a hazardous level. (ii) Local exhaust ventilation shall consist of movable hoods... not exposed to hazardous levels of fumes: (A) Lead base metals; (B) Cadmium-bearing filler materials...

  20. 29 CFR 1917.152 - Welding, cutting and heating (hot work) 12 (See also § 1917.2, definition of Hazardous cargo...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... reflective surfaces. (iv) Inert-gas metal-arc welding on stainless steel shall not be performed unless..., fumes and smoke below a hazardous level. (ii) Local exhaust ventilation shall consist of movable hoods... not exposed to hazardous levels of fumes: (A) Lead base metals; (B) Cadmium-bearing filler materials...

  1. 29 CFR 1917.152 - Welding, cutting and heating (hot work) 12 (See also § 1917.2, definition of Hazardous cargo...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... reflective surfaces. (iv) Inert-gas metal-arc welding on stainless steel shall not be performed unless..., fumes and smoke below a hazardous level. (ii) Local exhaust ventilation shall consist of movable hoods... not exposed to hazardous levels of fumes: (A) Lead base metals; (B) Cadmium-bearing filler materials...

  2. Measurement of chromium VI and chromium III in stainless steel welding fumes with electrom spectroscopy for chemical analysis and neutron activation analysis.

    PubMed

    Lautner, G M; Carver, J C; Konzen, R B

    1978-08-01

    Electron Spectroscopy for Chemical Analysis (ESCA) was explored as a means of studying the oxidation state of chromium in SMAC (coated electrode) stainless steel welding fume collected on Nucleopore filters in the laboratory. Chromuim VI and III (as a percent of the total chromium) obtained from ESCA analysis was applied to results from Neutron Activation Analysis (NAA) to yield an average of 69 microgram chromium VI per sample. Diphenylcarbazide/atomic absorption (DPC/AA) results are reported for samples submitted to an industrial laboratory. Possible chemical species and solubility of chromium VI in stainless steel fumes is discussed in light of analogy between the SMAC process and the manufacturing process for chromates.

  3. Bronchial reactions to exposure to welding fumes.

    PubMed Central

    Contreras, G R; Chan-Yeung, M

    1997-01-01

    OBJECTIVES: To study the airway response and its mechanism to welding fumes in six welders with respiratory symptoms. METHODS: Methacholine and welding challenge tests were carried out. The concentration of welding fumes during the exposure test was measured. On two subjects who developed bronchoconstricition to welding challenge, additional tests were carried out including prick, patch, and inhalation challenges with metal salt solutions. RESULTS: Three subjects developed immediate bronchial reaction to exposure to welding fume; one to mild steel and stainless steel welding, another to mild steel and galvanised welding, and one only to galvanised welding. They all had a moderate to pronounced degree of non-specific bronchial hyperresponsiveness. The concentration of fumes during welding tests, particularly to galvanised welding, was high. An inhalation challenge test with zinc chloride salt solution in two subjects who reacted to galvanised welding was negative. Prick and patch tests with zinc chloride were also negative. CONCLUSION: The airway response to welding in these subjects is non-specific and is due to irritation rather than to sensitisation. PMID:9538358

  4. Some difficulties in the assessment of electric arc welding fume.

    PubMed

    Hewitt, P J; Gray, C N

    1983-10-01

    During electric arc welding of metals, particulate fume in a variety of chemical compositions and physical forms is produced with consequent complex solution chemistry. Mechanisms of fume formation include condensation of vaporized metals to produce submicron diameter chains, and spatter of larger particles with subsequent oxidation to yield mixed metal oxide fumes in the respirable range. Complete dissolution of certain constituent metals such as chromium, can be achieved by fusion with potassium hydrogen sulphate. Extraction of hexavalent chromium by sodium carbonate/hydroxide solution is efficient and rapid, while some other extractants give erroneous results. Investigations show that constituent metals are released from the fume at different rates both in vitro and in vivo. The implications arising from the complex nature of welding fume for industrial hygiene assessment are discussed.

  5. Ethanol intake and sup 3 H-serotonin uptake I: A study in Fawn-Hooded rats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daoust, M.; Compagnon, P.; Legrand, E.

    1991-01-01

    Ethanol intake and synaptosomal {sup 3}H-serotonin uptake were studied in male Fawn-Hooded and Sprague-Dawley rats. Fawn-Hooded rats consumed more alcohol and more water than Sprague-Dawley rats. Plasma alcohol levels of Sprague-Dawley rats were not detectable but were about 5 mg/dl in Fawn-Hooded rats. Ethanol intake increased the Vmax of serotonin uptake in Fawn-Hooded rats in hippocampus and cortex, but not in thalamus. In Fawn-Hooded rats, serotonin uptake (Vmax) was higher than in Sprague-Dawley rats cortex. Ethanol intake reduced the Vmax of serotonin uptake in Fawn-Hooded rats in hippocampus and cortex. In cortex, the carrier affinity for serotonin was increased inmore » alcoholized Fawn-Hooded rats. These results indicate that synaptosomal {sup 3}H-serotonin uptake is affected by ethanol intake. In Fawn-Hooded rats, high ethanol consumption is associated with high serotonin uptake. In rats presenting high serotonin uptake, alcoholization reduces {sup 3}H-serotonin internalization in synaptosomes, indicating a specific sensitivity to alcohol intake of serotonin uptake system.« less

  6. Hood River and Pelton Ladder Evaluation Studies : Annual Report 1994.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Olsen, Erik A.; French, Rod A.; Ritchey, Alan D.

    1995-09-01

    In 1992, the Northwest Power Planning Council approved the Hood River and Pelton ladder master plans within the framework of the Columbia River Basin Fish and Wildlife Program. The master plans define an approach for implementing a hatchery supplementation program in the Hood River subbasin. The hatchery program as defined in the master plans is called the Hood River Hatchery Production Program (HRPP). The HRPP will be phased in over several years and will be jointly implemented by the Oregon Department of Fish and Wildlife (ODFW) and the Confederated Tribes of the Warm Springs (CTWS) Reservation. In December 1991, amore » monitoring and evaluation program was implemented in the Hood River subbasin to collect life history and production information on stocks of anadromous salmonids returning to the Hood River subbasin. The program was implemented to provide the baseline information needed to: (1) evaluate various management options for implementing the HRPP and (2) determine any post-project impacts the HRPP has on indigenous populations of resident fish. Information collected during the 1992-94 fiscal years will also be used to prepare an environmental impact statement (EIS) evaluating the program`s impact on the human environment. To begin construction on project facilities, it was proposed that the HRPP be implemented in two phases. Phase I would include work that would fall under a {open_quotes}categorical exclusion{close_quotes} from NEPA, and Phase II would include work requiring an EIS prior to implementation. This report summarizes the life history and escapement data collected in the Hood River subbasin and the status work of implemented under Phase I of the HR Life history and escapement data will be used to: (1) test the assumptions on which harvest and escapement goals for the Hood River and Pelton ladder master plans are based and (2) develop biologically based management recommendations for implementing the HRPP.« less

  7. Cobra Hoods Coming At You

    NASA Image and Video Library

    2004-06-17

    This 3-D image taken by the left and right eyes of the panoramic camera on NASA Mars Exploration Rover Spirit shows the odd rock formation dubbed Cobra Hoods center. 3D glasses are necessary to view this image.

  8. Physicochemical Characterization of Simulated Welding Fume from a Spark Discharge System

    PubMed Central

    Park, Jae Hong; Mudunkotuwa, Imali A.; Kim, Jong Sung; Stanam, Aditya; Thorne, Peter S.; Grassian, Vicki H.; Peters, Thomas M.

    2014-01-01

    This study introduces spark discharge system (SDS) as a way to simulate welding fumes. The SDS was developed using welding rods as electrodes with an optional coagulation chamber. The size, morphology, composition, and concentration of the fume produced and the concentration of ozone (O3) and nitrogen oxides (NOX) were characterized. The number median diameter (NMD) and total number concentration (TNC) of fresh fume particles were ranged 10–23 nm and 3.1×107–6×107 particles/cm3, respectively. For fresh fume particles, the total mass concentration (TMC) measured gravimetrically ranged 85–760 μg/m3. The size distribution was stable over a period of 12 h. The NMD and TNC of aged fume particles were ranged 81–154 nm and 1.5×106–2.7×106 particles/cm3, respectively. The composition of the aged fume particles was dominated by Fe and O with an estimated stoichiometry between that of Fe2O3 and Fe3O4. Concentrations of O3 and NOX were ranged 0.07–2.2 ppm and 1–20 ppm, respectively. These results indicate that the SDS is capable of producing stable fumes over a long-period that are similar to actual welding fumes. This system may be useful in toxicological studies and evaluation of instrumentation. PMID:25097299

  9. Decreasing biotoxicity of fume particles produced in welding process.

    PubMed

    Yu, Kuei-Min; Topham, Nathan; Wang, Jun; Kalivoda, Mark; Tseng, Yiider; Wu, Chang-Yu; Lee, Wen-Jhy; Cho, Kuk

    2011-01-30

    Welding fumes contain heavy metals, such as chromium, manganese, and nickel, which cause respiratory diseases and cancer. In this study, a SiO(2) precursor was evaluated as an additive to the shielding gas in an arc welding process to reduce the biotoxicity caused by welding fume particles. Transmission electron micrographic images show that SiO(2) coats on the surface of welding fume particles and promotes particle agglomeration. Energy dispersive X-ray spectroscopy further shows that the relative amount of silicon in these SiO(2)-coated agglomerates is higher than in baseline agglomerates. In addition, Escherichia coli (E. coli) exposed to different concentrations of pure SiO(2) particles generated from the arc welding process exhibits similar responses, suggesting that SiO(2) does not contribute to welding fume particle toxicity. The trend of E. coli growth in different concentrations of baseline welding fume particle shows the most significant inhibition occurs in higher exposure concentrations. The 50% lethal logarithmic concentrations for E. coli in arc welding particles of baseline, 2%, and 4.2% SiO(2) precursor additives were 823, 1605, and 1800 mg/L, respectively. Taken together, these results suggest that using SiO(2) precursors as an additive to arc welding shielding gas can effectively reduce the biotoxicity of welding fume. Copyright © 2010 Elsevier B.V. All rights reserved.

  10. Field-trip guide to Mount Hood, Oregon, highlighting eruptive history and hazards

    USGS Publications Warehouse

    Scott, William E.; Gardner, Cynthia A.

    2017-06-22

    This guidebook describes stops of interest for a geological field trip around Mount Hood volcano. It was developed for the 2017 International Association of Volcanology and Chemistry of the Earth’s Interior (IAVCEI) Scientific Assembly in Portland, Oregon. The intent of this guidebook and accompanying contributions is to provide an overview of Mount Hood, including its chief geologic processes, magmatic system, eruptive history, local tectonics, and hazards, by visiting a variety of readily accessible localities. We also describe coeval, largely monogenetic, volcanoes in the region. Accompanying the field-trip guidebook are separately authored contributions that discuss in detail the Mount Hood magmatic system and its products and behavior (Kent and Koleszar, this volume); Mount Hood earthquakes and their relation to regional tectonics and the volcanic system (Thelen and Moran, this volume); and young surface faults cutting the broader Mount Hood area whose extent has come to light after acquisition of regional light detection and ranging coverage (Madin and others, this volume).The trip makes an approximately 175-mile (280-kilometer) clockwise loop around Mount Hood, starting and ending in Portland. The route heads east on Interstate 84 through the Columbia River Gorge National Scenic Area. The guidebook points out only a few conspicuous features of note in the gorge, but many other guides to the gorge are available. The route continues south on the Mount Hood National Scenic Byway on Oregon Route 35 following Hood River, and returns to Portland on U.S. Highway 26 following Sandy River. The route traverses rocks as old as the early Miocene Eagle Creek Formation and overlying Columbia River Basalt Group of middle Miocene age, but chiefly lava flows and clastic products of arc volcanism of late Miocene to Holocene age.

  11. Numerical analysis of fume formation mechanism in arc welding

    NASA Astrophysics Data System (ADS)

    Tashiro, Shinichi; Zeniya, Tasuku; Yamamoto, Kentaro; Tanaka, Manabu; Nakata, Kazuhiro; Murphy, Anthony B.; Yamamoto, Eri; Yamazaki, Kei; Suzuki, Keiichi

    2010-11-01

    In order to clarify the fume formation mechanism in arc welding, a quantitative investigation based on the knowledge of interaction among the electrode, arc and weld pool is indispensable. A fume formation model consisting of a heterogeneous condensation model, a homogeneous nucleation model and a coagulation model has been developed and coupled with the GTA or GMA welding model. A series of processes from evaporation of metal vapour to fume formation from the metal vapour was totally investigated by employing this simulation model. The aim of this paper is to visualize the fume formation process and clarify the fume formation mechanism theoretically through a numerical analysis. Furthermore, the reliability of the simulation model was also evaluated through a comparison of the simulation result with the experimental result. As a result, it was found that the size of the secondary particles consisting of small particles with a size of several tens of nanometres reached 300 nm at maximum and the secondary particle was in a U-shaped chain form in helium GTA welding. Furthermore, it was also clarified that most part of the fume was produced in the downstream region of the arc originating from the metal vapour evaporated mainly from the droplet in argon GMA welding. The fume was constituted by particles with a size of several tens of nanometres and had similar characteristics to that of GTA welding. On the other hand, if the metal transfer becomes unstable and the metal vapour near the droplet diffuses directly towards the surroundings of the arc not getting into the plasma flow, the size of the particles reaches several hundred nanometres.

  12. Welding fume exposure and chronic obstructive pulmonary disease in welders.

    PubMed

    Koh, D-H; Kim, J-I; Kim, K-H; Yoo, S-W

    2015-01-01

    Occupational exposure is estimated to contribute 15% to the burden of chronic obstructive pulmonary disease (COPD). Welding fumes are suspected to accelerate the decline of lung function and development of COPD. To examine the relationship between welding fume exposure and COPD in Korean shipyard welders. The study involved a group of male welders working at two shipyards who underwent an annual health examination in 2010. Subjects completed a questionnaire about smoking habits and occupational history and a pulmonary function test (PFT) was carried out with strict quality control measures. Welding fume exposure concentrations were estimated using 884 measurements taken between 2002 and 2009 in one of the shipyards. Multiple linear and logistic regression was employed to evaluate the association between cumulative fume exposure and lung function parameters, controlling for age, height and cigarette smoking. Two hundred and forty subjects participated, with a mean age of 48 and mean work duration of 15 years. The mean cumulative fume exposure was 7.7mg/m(3). The prevalence of COPD was 15%. FEV1 and FVC showed non-significant negative correlations with cumulative fume exposure. Odds ratios of COPD were significantly elevated for the middle (3.9; 95% CI 1.4-13.3) and high exposure groups (3.8; 95% CI 1.03-16.2) compared with the low fume exposure group. Our findings support an association between welding fume exposure and increased risk of COPD. Further prospective study is needed to investigate whether this is a causal relationship. © The Author 2014. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. 33 CFR 334.1220 - Hood Canal, Bangor; naval restricted areas.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Hood Canal, Bangor; naval..., Bangor; naval restricted areas. (a) Hood Canal, Bangor; Naval restricted areas—(1) Area No. 1. That area...) Area No. 1. No person or vessel shall enter this area without permission from the Commander, Naval...

  14. 33 CFR 334.1220 - Hood Canal, Bangor; naval restricted areas.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 3 2011-07-01 2011-07-01 false Hood Canal, Bangor; naval..., Bangor; naval restricted areas. (a) Hood Canal, Bangor; Naval restricted areas—(1) Area No. 1. That area...) Area No. 1. No person or vessel shall enter this area without permission from the Commander, Naval...

  15. Pulmonary fibrosis and exposure to steel welding fume.

    PubMed

    Cosgrove, M P

    2015-12-01

    Arc welders who have been exposed to high concentrations of steel welding fume for prolonged periods of time may develop pulmonary fibrosis but the nature of the fibrotic changes has been debated over the last 80 years without any clear international consensus. To characterize the nature of the pulmonary fibrosis that develops in response to steel welding fume exposure and to provide a working hypothesis that would explain the findings of the existing research, to provide a platform for future research and to inform future occupational and clinical management of welders with pulmonary effects from welding fume. Review of the world literature on pulmonary fibrosis and welding of steel in all languages using PubMed, with further secondary search of references in the articles found in the primary search. Google and Reference Manager were used as further confirmatory search tools. Only case series and case reports were found but these provided consistent evidence that the consequence of exposure to steel welding fume at high levels for a prolonged period of time is a type of pulmonary fibrosis similar to, and possibly the same as, respiratory bronchiolitis which eventually develops into desquamative interstitial pneumonia with ongoing exposure. Steel welding fume may cause an occupational respiratory bronchiolitis which may develop into de squamative interstitial pneumonia with ongoing exposure. This concept may explain the difficulties in interpreting the wider literature on welding fume and lung function at lower exposures and may also explain the increased risk of lung cancer in welders. © The Author 2015. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. MAGNETIC FIELD INFLUENCE ON NGF-STIMULATED NEURITE OUTGROWTH IN PC-12 CELLS: EFFECT OF PAINT FUMES

    EPA Science Inventory

    MAGNETIC FIELD INFLUENCE ON NGF-STIMULATED NEURITE OUTGROWTH IN PC-12 CELLS: EFFECT OF PAINT FUMES. C. F. Blackman1, D. E. House2*, S. G. Benane3*, A. Ubeda4, M.A. TrilIo4. 1 National Health and Environmental Effects Research Laboratory, EPA,
    Research Triangle Park, North Caro...

  17. Genotoxic Effects of Exposure to Gasoline Fumes on Petrol Pump Workers.

    PubMed

    Shaikh, Amrin; Barot, Darshana; Chandel, Divya

    2018-04-01

    Petrol pump workers are occupationally exposed to gasoline and its fumes consisting of several mutagenic chemicals. To evaluate the genotoxic effects of exposure to gasoline fumes on petrol pump workers. The study groups included 70 petrol pump workers (exposed group) and 70 healthy age-matched individuals with no known exposure (comparison group). Buccal micronucleus cytome assay (BMCyt) was performed to check the genotoxicity caused due to inhalation of gasoline fumes. The frequencies of micronucleated cells, nuclear bud, condensed chromatin cells, karyorrhectic cells, pyknotic cells, and karyolytic cells were significantly higher in the exposed workers compared to the comparison group. Exposure to gasoline fumes is associated with increased frequency of cell abnormalities. This may lead to various health consequences including cancer in those occupationally exposed to gasoline fumes.

  18. Soluble transition metals cause the pro-inflammatory effects of welding fumes in vitro.

    PubMed

    McNeilly, Jane D; Heal, Mathew R; Beverland, Iain J; Howe, Alan; Gibson, Mark D; Hibbs, Leon R; MacNee, William; Donaldson, Ken

    2004-04-01

    Epidemiological studies have consistently reported a higher incidence of respiratory illnesses such as bronchitis, metal fume fever (MFF), and chronic pneumonitis among welders exposed to high concentrations of metal-enriched welding fumes. Here, we studied the molecular toxicology of three different metal-rich welding fumes: NIMROD 182, NIMROD c276, and COBSTEL 6. Fume toxicity in vitro was determined by exposing human type II alveolar epithelial cell line (A549) to whole welding fume, a soluble extract of fume or the "washed" particulate. All whole fumes were significantly toxic to A549 cells at doses >63 microg ml(-1) (TD 50; 42, 25, and 12 microg ml(-1), respectively). NIMROD c276 and COBSTEL 6 fumes increased levels of IL-8 mRNA and protein at 6 h and protein at 24 h, as did the soluble fraction alone, whereas metal chelation of the soluble fraction using chelex beads attenuated the effect. The soluble fraction of all three fumes caused a rapid depletion in intracellular glutathione following 2-h exposure with a rebound increase by 24 h. In addition, both nickel based fumes, NIMROD 182 and NIMROD c276, induced significant reactive oxygen species (ROS) production in A549 cells after 2 h as determined by DCFH fluorescence. ICP analysis confirmed that transition metal concentrations were similar in the whole and soluble fractions of each fume (dominated by Cr), but significantly less in both the washed particles and chelated fractions. These results support the hypothesis that the enhanced pro-inflammatory responses of welding fume particulates are mediated by soluble transition metal components via an oxidative stress mechanism.

  19. Evaluation of an aerosol photometer for monitoring welding fume levels in a shipyard.

    PubMed

    Glinsmann, P W; Rosenthal, F S

    1985-07-01

    A direct reading aerosol photometer (Sibata P-5 Digital Dust Indicator) was used to assess fume levels from welding and burning operations in a shipyard. The photometer was calibrated with gravimetric analysis of filter samples collected simultaneously with instrument readings. A six-fold difference between calibration factors for personal and area samples was found. This difference can be explained by expected changes in particle size distributions in welding fume. Monitoring of various work situations was performed in order to assess the value of the photometer for the measurement of fume. Measurements categorized by enclosure of space and quality of ventilation indicated the presence of high fume levels in semi-enclosed and enclosed spaces. The build up of welding fume in an enclosed space occurred over several minutes after the arc was struck. Decay likewise required several minutes. During welding, wide fluctuations of fume concentrations were found. Thus a single reading was not adequate to characterize average fume levels. Although this type of instrument is useful for locating areas with high fume levels and monitoring the effectiveness of ventilation, the uncertainty in calibration factors makes accurate determinations of fume levels difficult.

  20. Experience Gained from Designing Exhaust Hoods of Large Steam Turbines Using Computational Fluid Dynamics Techniques

    NASA Astrophysics Data System (ADS)

    Galaev, S. A.; Ris, V. V.; Smirnov, E. M.; Babiev, A. N.

    2018-06-01

    Experience gained from designing exhaust hoods for modernized versions of K-175/180-12.8 and K-330-23.5-1 steam turbines is presented. The hood flow path is optimized based on the results of analyzing equilibrium wet steam 3D flow fields calculated using up-to-date computation fluid dynamics techniques. The mathematical model constructed on the basis of Reynolds-averaged Navier-Stokes equations is validated by comparing the calculated kinetic energy loss with the published data on full-scale experiments for the hood used in the K-160-130 turbine produced by the Kharkiv Turbine-Generator Works. Test calculations were carried out for four turbine operation modes. The obtained results from validating the model with the K-160-130 turbine hood taken as an example were found to be equally positive with the results of the previously performed calculations of flow pattern in the K-300-240 turbine hood. It is shown that the calculated coefficients of total losses in the K-160-130 turbine hood differ from the full-scale test data by no more than 5%. As a result of optimizing the K-175/180-12.8 turbine hood flow path, the total loss coefficient has been decreased from 1.50 for the initial design to 1.05 for the best of the modification versions. The optimized hood is almost completely free from supersonic flow areas, and the flow through it has become essentially more uniform both inside the hood and at its outlet. In the modified version of the K-330-23.5-1 turbine hood, the total loss coefficient has been decreased by more than a factor of 2: from 2.3 in the hood initial design to a value of 1.1 calculated for the hood final design version and sizes adopted for developing the detailed design. Cardinally better performance of both the hoods with respect to their initial designs was achieved as a result of multicase calculations, during which the flow path geometrical characteristics were sequentially varied, including options involving its maximally possible expansion and

  1. The Influence of Inlet Asymmetry on Steam Turbine Exhaust Hood Flows.

    PubMed

    Burton, Zoe; Hogg, Simon; Ingram, Grant L

    2014-04-01

    It has been widely recognized for some decades that it is essential to accurately represent the strong coupling between the last stage blades (LSB) and the diffuser inlet, in order to correctly capture the flow through the exhaust hoods of steam turbine low pressure cylinders. This applies to any form of simulation of the flow, i.e., numerical or experimental. The exhaust hood flow structure is highly three-dimensional and appropriate coupling will enable the important influence of this asymmetry to be transferred to the rotor. This, however, presents challenges as the calculation size grows rapidly when the full annulus is calculated. The size of the simulation means researchers are constantly searching for methods to reduce the computational effort without compromising solution accuracy. However, this can result in excessive computational demands in numerical simulations. Unsteady full-annulus CFD calculation will remain infeasible for routine design calculations for the foreseeable future. More computationally efficient methods for coupling the unsteady rotor flow to the hood flow are required that bring computational expense within realizable limits while still maintaining sufficient accuracy for meaningful design calculations. Research activity in this area is focused on developing new methods and techniques to improve accuracy and reduce computational expense. A novel approach for coupling the turbine last stage to the exhaust hood employing the nonlinear harmonic (NLH) method is presented in this paper. The generic, IP free, exhaust hood and last stage blade geometries from Burton et al. (2012. "A Generic Low Pressure Exhaust Diffuser for Steam Turbine Research,"Proceedings of the ASME Turbo Expo, Copenhagen, Denmark, Paper No. GT2012-68485) that are representative of modern designs, are used to demonstrate the effectiveness of the method. This is achieved by comparing results obtained with the NLH to those obtained with a more conventional mixing

  2. In vitro RPM fibrogenic potential assay of welding fumes.

    PubMed Central

    Stern, R M; Pigott, G H

    1983-01-01

    The fibrogenic potential of 11 different welding fumes and metallic aerosols, considered to be reference standard surrogates for the commonly used welding technologies and applications responsible for 70% of welders exposure, is screened by using the rat peritoneal macrophage (RPM) in vitro bioassay. Only one class of fumes, that from the manual metal are welding of stainless steel, shows distinct fibrogenic potential. This fume, however, is not common to more than four or five of the heretofore 90 cases of pulmonary fibrosis reported among welders. Thus, although insoluble Cr(VI) is probably the active fibrogen in stainless steel fumes, an etiological factor common to all fibrogenic welding exposures must be sought; it is tentatively proposed to be NO chi, a potent experimental in vivo fibrogen copiously produced by certain welding processes and ubiquitous at low concentrations in the welding environment. PMID:6641657

  3. Effects of Hoods and Flame-Retardant Fabrics on WBGT Clothing Adjustment Factors.

    PubMed

    Ashley, Candi D; Bernard, Thomas E

    2008-01-01

    Personal protective clothing (PPC) may include hoods and flame-retardant (FR) fabrics that may affect heat transfer and, thus, the critical wet bulb globe temperature (WBGT crit) to maintain thermal equilibrium. The purpose of this study was to compare the differences in WBGT crit for hooded vs. nonhooded versions of particle barrier and vapor barrier coveralls as well as for coveralls made of two flame-retardant fabrics (INDURA cotton and Nomex). Acclimated men (n = 11) and women (n = 4) walked on a treadmill in a climatic chamber at 180 W/m2 wearing four different ensembles: limited-use, particle barrier coveralls with and without a hood (Tyvek 1427), and limited-use vapor barrier coveralls with and without a hood (Tychem QC, polyethylene-coated Tyvek). Twelve of the participants wore one of two flame-retardant coveralls. All participants wore standard cotton clothing. Progressive exposure testing at 50% relative humidity (rh) was designed so that each subject established a physiological steady-state followed by a clear loss of thermal equilibrium. WBGT crit was the WBGT 5 min prior to a loss of thermal equilibrium. Hooded ensembles had a lower WBGT crit than the nonhooded ensembles. The difference suggested a clothing adjustment of 1 degrees C for hoods. There were no significant differences among the FR ensembles and cotton work cloths, and the proposed clothing adjustment for FR coveralls clothing is 0 degrees C.

  4. 42 CFR 84.202 - Air velocity and noise levels; hoods and helmets; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Air velocity and noise levels; hoods and helmets... PROTECTIVE DEVICES Chemical Cartridge Respirators § 84.202 Air velocity and noise levels; hoods and helmets; minimum requirements. Noise levels generated by the respirator will be measured inside the hood or helmet...

  5. 42 CFR 84.140 - Air velocity and noise levels; hoods and helmets; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Air velocity and noise levels; hoods and helmets... PROTECTIVE DEVICES Supplied-Air Respirators § 84.140 Air velocity and noise levels; hoods and helmets; minimum requirements. Noise levels generated by the respirator will be measured inside the hood or helmet...

  6. 42 CFR 84.202 - Air velocity and noise levels; hoods and helmets; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Air velocity and noise levels; hoods and helmets... PROTECTIVE DEVICES Chemical Cartridge Respirators § 84.202 Air velocity and noise levels; hoods and helmets; minimum requirements. Noise levels generated by the respirator will be measured inside the hood or helmet...

  7. 42 CFR 84.140 - Air velocity and noise levels; hoods and helmets; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Air velocity and noise levels; hoods and helmets... PROTECTIVE DEVICES Supplied-Air Respirators § 84.140 Air velocity and noise levels; hoods and helmets; minimum requirements. Noise levels generated by the respirator will be measured inside the hood or helmet...

  8. Characterization of Particulate Fume and Oxides Emission from Stainless Steel Plasma Cutting.

    PubMed

    Wang, Jun; Hoang, Tien; Floyd, Evan L; Regens, James L

    2017-04-01

    Plasma cutting is a metal fabrication process that employs an electrically conductive plasma arc to cut metals. The metal fume emitted from stainless steel plasma cutting may consist of hexavalent chromium (Cr6+), which is a carcinogen, and other toxicants. Overexposure to plasma cutting fume may cause pulmonary toxicity and other health effects. This study was to evaluate the effects of operation parameters (arc current and arc time) on the fume formation rates, Cr6+ and other oxides concentrations, particle size distributions (PSD), and particle morphology. A fume chamber and high-volume pump were used to collect fume produced from cutting ER308L stainless steel plates with arc currents varying between 20 and 50 A. The amount of fume collected on glass fiber filters was gravimetrically determined and normalized to arc time. Cr6+ and other oxides in the fume were analyzed using ion chromatography. PSD of the fume was examined using a scanning mobility particle sizer and an aerodynamic particle sizer for fine and coarse fractions, respectively. The particle morphology was imaged through a transmission electron microscope (TEM). Total fume generation rate increased with arc current and ranged from 16.5 mg min-1 at 20 A to 119.0 mg min-1 at 50 A. Cr6+ emissions (219.8-480.0 µg min-1) from the plasma cutting were higher than welding fume in a previous study. Nitrogen oxides level can be an indicator of oxidation level and Cr6+ formation (R = 0.93). Both PSD measurement and TEM images confirmed a multimodal size distribution. A high concentration of a fine fraction of particles with geometric mean sizes from 96 to 235 nm was observed. Higher arc current yielded more particles, while lower arc current was not able to penetrate the metal plates. Hence, the worker should optimize the arc current to balance cut performance and fume emission. The findings indicated that arc current was the dominant factor in fume emission from plasma cutting. Appropriate ventilation and

  9. Increased lung function decline in blue-collar workers exposed to welding fumes.

    PubMed

    Thaon, Isabelle; Demange, Valérie; Herin, Fabrice; Touranchet, Annie; Paris, Christophe

    2012-07-01

    There is no consensus at the present time about the effect of welding on lung function decline. This study compared lung function decline between blue-collar workers exposed and not exposed to welding fumes in a French longitudinal cohort of 21,238 subjects aged 37 to 52 years at inclusion. Medical data, occupation, sector of activity, and spirometry were recorded twice by occupational physicians in 1990 and 1995. A job-exposure matrix was used to identify 503 male blue-collar workers exposed to welding fumes and 709 control subjects and to define the weekly duration of exposure to welding fumes. Baseline lung function parameters were higher in workers exposed to welding fumes than in control subjects. After a 5-year follow-up, welding-fume exposure was associated with a nonsignificant decline in FVC (P = .06) and FEV(1) (P = .07) after adjustment for age, pack-years, BMI, and baseline value of the parameter. A significant accelerated decline in FEV(1) (P = .046) was also observed in never smokers exposed to welding fumes. An “exposure-response” relationship was observed between FEV(1) decline and weekly duration of exposure to welding fumes in nonsmokers but not in smokers. Blue-collar workers exposed to welding fumes showed accelerated decline in lung function, which, in nonsmokers, was related to weekly duration of exposure.

  10. Urinary β2 microglobulin in workers exposed to arc welding fumes.

    PubMed

    Aminian, Omid; Eftekhari, Saeid; Mazaheri, Maria; Sharifian, Seyed Akbar; Sadeghniiat-Haghighi, Khosro

    2011-01-01

    Welding is a process in which two or more metals are attached by the use of heat and, in some cases, pressure. Direct exposure and inhalation of welding fumes causes acute and chronic side effects in humans. Kidney damage is one of these important side effects. β(2) microglobulin is an 11.8 kilodalton protein and levels increase in the case of some inflammatory and viral diseases, or kidney malfunction and autoimmune diseases. In this study measurements of β(2) microglobulin were used as a criterion for assessing effects on the kidneys of workers exposed to welding fumes. The study population were electric arc welders in an industrial plant in Tehran, Iran. For control we selected workers who did not have any exposure to welding fumes. Both groups were selected on the basis of a questionnaire and the consideration of criteria for inclusion and exclusion. In the end 50 cases and 50 controls were chosen. A urine sample was collected from all participants and urinary pH was set to between 6-8 using NaOH (1M). Sample transportation to the laboratory complied with the related standards. The samples were assessed using the ORG 5BM kit. For quantitative assessment of β(2) microglobulin we used the Enzyme-linked Immunosorbent Assay (ELISA) method. The ages of the welders ranged from 21 to 48 years (mean=30.5 ± 5.9 yrs) and of controls from 23 to 56 years (mean=31.8 ± 5.9 yrs). Mean employment duration was 7.86 ± 5.01 years (range 2 to 27 years) for welders. Mean β(2) microglobulin level was 0.10 ± 0.096 μg/ml in welders and 0.11 ± 0.06 in controls. This difference was not statistically significant (P=0.381). In conclusion we don't find that exposure to electric arc welding fumes cause a significant change in urinary β(2) microglobulin compared to the control group.

  11. How To Curb the Appetite for Energy in University Laboratories.

    ERIC Educational Resources Information Center

    Zsirai, Ted; Wright, Michaella

    2001-01-01

    Discusses ways to cut rising energy costs within university laboratories by using heat recovery systems and variable volume exhaust hood systems. Explores the implementation of broad-based, sustainable laboratory classroom design concepts. (GR)

  12. 77 FR 26699 - Safety Zone; Coast Guard Exercise, Hood Canal, WA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-07

    ... would be impracticable to delay this important exercise to allow for a delayed effective date...-AA00 Safety Zone; Coast Guard Exercise, Hood Canal, WA AGENCY: Coast Guard, DHS. ACTION: Temporary... a Coast Guard Ready for Operations exercise in Hood Canal, WA that will take place between May 08...

  13. Interlaboratory comparison for the determination of the soluble fraction of metals in welding fume samples.

    PubMed

    Berlinger, Balazs; Harper, Martin

    2018-02-01

    There is interest in the bioaccessible metal components of aerosols, but this has been minimally studied because standardized sampling and analytical methods have not yet been developed. An interlaboratory study (ILS) has been carried out to evaluate a method for determining the water-soluble component of realistic welding fume (WF) air samples. Replicate samples were generated in the laboratory and distributed to participating laboratories to be analyzed according to a standardized procedure. Within-laboratory precision of replicate sample analysis (repeatability) was very good. Reproducibility between laboratories was not as good, but within limits of acceptability for the analysis of typical aerosol samples. These results can be used to support the development of a standardized test method.

  14. Internal Performance of a Fixed-Shroud Nonaxisymmetric Nozzle Equipped with an Aft-Hood Exhaust Deflector

    NASA Technical Reports Server (NTRS)

    Asbury, Scott C.

    1997-01-01

    An investigation was conducted in the model preparation area of the Langley 16-Foot Transonic Tunnel to determine the internal performance of a fixed-shroud nonaxisymmetric nozzle equipped with an aft-hood exhaust deflector. Model geometric parameters investigated included nozzle power setting, aft-hood deflector angle, throat area control with the aft-hood deflector deployed, and yaw vector angle. Results indicate that cruise configurations produced peak performance in the range consistent with previous investigations of nonaxisymmetric convergent-divergent nozzles. The aft-hood deflector produced resultant pitch vector angles that were always less than the geometric aft-hood deflector angle when the nozzle throat was positioned upstream of the deflector exit. Significant losses in resultant thrust ratio occurred when the aft-hood deflector was deployed with an upstream throat location. At each aft-hood deflector angle, repositioning the throat to the deflector exit improved pitch vectoring performance and, in some cases, substantially improved resultant thrust ratio performance. Transferring the throat to the deflector exit allowed the flow to be turned upstream of the throat at subsonic Mach numbers, thereby eliminating losses associated with turning supersonic flow. Internal throat panel deflections were largely unsuccessful in generating yaw vectoring.

  15. Cognitive symptoms and welding fume exposure.

    PubMed

    Ross, John A S; Macdiarmid, Jennifer I; Semple, Sean; Watt, Stephen J; Moir, Gill; Henderson, George

    2013-01-01

    Prevalence of moderate to severe cognitive symptoms is markedly higher in UK professional divers who have also worked as a welder (28%) than in either divers who have not welded (18%) or offshore workers who have worked neither as a diver nor as a welder (6%). To determine whether cognitive symptoms are related to welding fume exposure or diving. Three age-matched groups of male workers were studied using postal questionnaire: professional divers who had worked as a welder (PDW, n = 361), professional welders who had not dived (NDW, n = 352), and offshore oil field workers who had neither dived nor welded (NDNW, n =503). Health-related quality of life was assessed by the Short Form 12 questionnaire (SF12). Cognitive symptomatology was assessed using the Cognitive Failures Questionnaire (CFQ). A single variable for welding fume exposure (mg m(-3) days) was calculated, incorporating welding experience in different environments and using different welding techniques and respiratory protective equipment. The level of fume exposure during hyperbaric welding operations was measured during such work as ambient PM(10) (particles of 10 µm or less). Diving exposure was assessed as the number of dives performed plus the number of days spent working during saturation diving. Questionnaires were returned by 153 PDW, 108 NDW, and 252 NDNW. SF12 scores were the same in all groups and fell within normative values. Mean (95% CI) CFQ scores were higher in PDW [40.3 (37.7-42.9)] than in both NDW [34.6 (31.6-37.7)] and NDNW [32.1 (30.4-33.9)], but the scores in no groups fell outside the normative range. The mean PM(10) exposure during hyperbaric welding operations was 2.58 mg m(-3). The geometric mean mg m(-3) days (95% CI) for welding fume exposure in NDW [33 128 (24 625-44 567) n = 85] was higher than for that in PDW [10 904 (8103-14 673) n = 112]. For PDW the geometric mean (95% CI) diving exposure was 1491 [(1192-1866) n = 94] dives and days in saturation. In the general linear

  16. Fort Hood Building and Landscape Inventory with WWII and Cold War Context

    DTIC Science & Technology

    2007-03-01

    barracks, 1970s (NARA)........................................................... 112 Figure 37. Palmer Movie Theater (NARA...revised 1953) showing layout of Hood Village and trailer park (Fort Hood...arms ammunition storage building #92012 (ERDC-CERL, 2004). ......... 260 Figure 163: Radio reception building #92063 (ERDC-CERL, 2004

  17. Inhalation of gas metal arc-stainless steel welding fume promotes lung tumorigenesis in A/J mice.

    PubMed

    Falcone, Lauryn M; Erdely, Aaron; Meighan, Terence G; Battelli, Lori A; Salmen, Rebecca; McKinney, Walter; Stone, Samuel; Cumpston, Amy; Cumpston, Jared; Andrews, Ronnee N; Kashon, Michael; Antonini, James M; Zeidler-Erdely, Patti C

    2017-08-01

    Epidemiologic studies suggest an increased risk of lung cancer with exposure to welding fumes, but controlled animal studies are needed to support this association. Oropharyngeal aspiration of collected "aged" gas metal arc-stainless steel (GMA-SS) welding fume has been shown by our laboratory to promote lung tumor formation in vivo using a two-stage initiation-promotion model. Our objective in this study was to determine whether inhalation of freshly generated GMA-SS welding fume also acts as a lung tumor promoter in lung tumor-susceptible mice. Male A/J mice received intraperitoneal (IP) injections of corn oil or the chemical initiator 3-methylcholanthrene (MCA; 10 µg/g) and 1 week later were exposed by whole-body inhalation to air or GMA-SS welding aerosols for 4 h/d × 4 d/w × 9 w at a target concentration of 40 mg/m 3 . Lung nodules were enumerated at 30 weeks post-initiation. GMA-SS fume significantly promoted lung tumor multiplicity in A/J mice initiated with MCA (16.11 ± 1.18) compared to MCA/air-exposed mice (7.93 ± 0.82). Histopathological analysis found that the increased number of lung nodules in the MCA/GMA-SS group were hyperplasias and adenomas, which was consistent with developing lung tumorigenesis. Metal deposition analysis in the lung revealed a lower deposited dose, approximately fivefold compared to our previous aspiration study, still elicited a significant lung tumorigenic response. In conclusion, this study demonstrates that inhaling GMA-SS welding fume promotes lung tumorigenesis in vivo which is consistent with the epidemiologic studies that show welders may be at an increased risk for lung cancer.

  18. The humoral immune response of mice exposed to simulated road paving-like asphalt fumes.

    PubMed

    Anderson, Stacey E; Munson, Albert E; Tomblyn, Seth; Meade, B Jean; Diotte, Nicole M

    2008-07-01

    Asphalt is a complex mixture of organic molecules, including polycyclic aromatic hydrocarbons (PAH), which have been reported to cause serious adverse health effects in humans. Workers in manufacturing and construction trades exposed to asphalt are potentially at risk for being exposed to asphalt fumes and PAHs. Epidemiological investigations have collected mounting evidence that chemicals found in asphalt fumes present carcinogenic and possibly immunotoxic hazards. Studies evaluating the immunotoxic effects of asphalt fume are limited due to the large number of variables associated with asphalt fume exposures. This work investigates the immuno-toxic effects of road paving-like asphalt fume by analyzing the in vivo IgM response to a T-dependent antigen after exposure to whole, vapor, and particulate phase road paving-like asphalt fumes and asphalt fume condensate. Systemic exposures via intraperitoneal injection of asphalt fume condensate (at 0.625 mg/kg) and the particulate phase (at 5 mg/kg) resulted in significant reductions in the specific spleen IgM response to SRBC. Pharyngeal aspiration of the asphalt fume condensate (at 5 mg/kg) also resulted in significant suppression of the IgM response to SRBC. A significant reduction in the specific spleen IgM activity was observed after inhalation exposure to whole asphalt fumes (35 mg/m(3)) and the vapor components (11 mg/m(3)). Dermal exposures to the asphalt fume condensate resulted in significant reductions in the total (at 50 mg/kg) and specific (at 250 mg/kg) spleen IgM response to SRBC. These results demonstrate that exposure to road paving-like asphalt fumes is immunosuppressive through systemic, respiratory, and dermal routes of exposure in a murine model and raise concerns regarding the potential for adverse immunological effects.

  19. Welding-fume-induced transmission loss in tapered optical fibers

    NASA Astrophysics Data System (ADS)

    Yi, Ji-Haeng

    2015-09-01

    This paper presents a method for sensing welding fumes in real time. This method is based on the results of nanoparticle-induced optical-fiber loss experiments that show that the losses are determined by the nanoparticle density and the taper waist. The tapered fiber is obtained by applying heat radiated from hot quartz, and monitoring is done in real time. First, the durability of the tapered fiber during the welding process is proven. Then, the loss is categorized by using the sizes of welding fume particles. The sensitivity to welding fumes increases with increasing size of the particles; consequently, the dimension of the taper waist decreases.

  20. Hood River and Pelton Ladder Evaluation Studies, Annual Report 2000-2001.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Olsen, Erik

    The Bonneville Power Administration (BPA) funded the development of two master plans which outline the rationale, and general approach, for implementing a defined group of projects that are an integral part of a comprehensive watershed goal to 'Protect, enhance and restore wild and natural populations of anadromous and resident fish within the Hood River Subbasin'. The Hood River Production Master Plan and the Pelton Ladder Master Plan were completed in 1991 and subsequently approved by the Northwest Power Planning Council in 1992. Action items identified in the two master plans, as well as in a later document entitled 'Hood River/Peltonmore » Ladder Master Agreement' (ODFW and CTWSRO Undated), are designed to achieve two biological fish objectives: (1) to increase production of wild summer and winter steelhead (Oncorhynchus mykiss) to levels commensurate with the subbasins current carrying capacity and (2) re-establishing a self-sustaining population of spring chinook salmon (Oncorhynchus tshawytscha). Numerical fish objectives for subbasin escapement, spawner escapement, and subbasin harvest are defined for each of these species in Coccoli (2000). Several projects are presently funded by the BPA to achieve the Hood River subbasin's numerical fish objectives for summer and winter steelhead and spring chinook salmon. They include BPA project numbers 1998-021-00 (Hood River Fish Habitat), 1998-053-03 (Hood River Production Program - CTWSRO: M&E), 1998-053-07 (Parkdale Fish Facility), 1998-053-08 (Powerdale/Oak Springs O&M), and 1998-053-12 (Hood River Steelhead Genetics Study). Collectively, they are implemented under the umbrella of what has come to be defined as the Hood River Production Program (HRPP). The HRPP is jointly implemented by the Oregon Department of Fish and Wildlife (ODFW) and The Confederated Tribes of the Warm Springs Reservation of Oregon (CTWSRO). Strategies for achieving the HRPP's biological fish objectives for the Hood River subbasin were

  1. 77 FR 59083 - Safety Zone; Coast Guard Exercise, Hood Canal, Washington

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-26

    ... 1625-AA00 Safety Zone; Coast Guard Exercise, Hood Canal, Washington AGENCY: Coast Guard, DHS. ACTION... involved in a Coast Guard Ready for Operations exercise in Hood Canal, WA that will take place between Oct... during the exercise and will do so by prohibiting any person or vessel from entering or remaining in the...

  2. Recovery from welding-fume-exposure-induced MRI T1 signal intensities after cessation of welding-fume exposure in brains of cynomolgus monkeys.

    PubMed

    Han, Jeong Hee; Chung, Yong Hyun; Park, Jung Duck; Kim, Choong Yong; Yang, Seoung Oh; Khang, Hyun Soo; Cheong, Hae Kwan; Lee, Jong Seong; Ha, Chang Soo; Song, Chang-Woo; Kwon, Il Hoon; Sung, Jae Hyuck; Heo, Jeong Doo; Kim, Na-Young; Huang, Mingai; Cho, Myung Haing; Yu, Il Je

    2008-09-01

    The shortening of the MRI T1 relaxation time, indicative of a high signal intensity in a T1-weighted MRI, is known as a useful biomarker for Mn exposure after short-term welding-fume exposure. A previous monkey experimental study found that the T1 relaxation times decreased time-dependently after exposure, and a visually detectable high signal intensity appeared after 150 days of exposure. The nadir for the shortening of the T1 relaxation time was also previously found to correspond well with the blood Mn concentration in welders, suggesting a correlation between a prolonged high blood Mn concentration and shortened T1 relaxation time. Accordingly, to clarify the clearance of the brain Mn concentration after the cessation of welding-fume exposure, cynomolgus monkeys were assigned to 3 groups-unexposed, low dose (31 mg/m(3) total suspended particulate (TSP), 0.9 mg Mn/m(3)), and high dose (62 mg/m(3) TSP, 1.95 mg Mn/m(3))-and exposed to manual metal-arc stainless steel (MMA-SS) welding fumes for 2 h per day for 8 mo in an inhalation chamber system equipped with an automatic fume generator. After reaching the peak MRI T1 signal intensity (shortest T1 relaxation time), the monkeys were allowed to recover by ceasing the welding-fume exposure. Within 2 mo, the MRI T1 signal intensities for the exposed monkeys returned to nearly the same level as those for the unexposed monkeys, indicating the potential for recovery from a high MRI T1 signal intensity induced by welding-fume exposure, even after prolonged exposure. Clearance of the Mn tissue concentration was also demonstrated in the globus pallidus, plus other tissues from the brain, liver, spleen, and blood. In contrast, there was no clearance of the lung concentrations of Mn, indicating that a soluble form of Mn was transported to the blood and brain. Therefore, the solubility of Mn in welding fumes would appear to be an important determinant as regards the retention of blood Mn levels and brain tissue Mn

  3. Immunotoxicology of arc welding fume: Worker and experimental animal studies

    PubMed Central

    Zeidler-Erdely, Patti C.; Erdely, Aaron; Antonini, James M.

    2015-01-01

    Arc welding processes generate complex aerosols composed of potentially hazardous metal fumes and gases. Millions of workers worldwide are exposed to welding aerosols daily. A health effect of welding that is of concern to the occupational health community is the development of immune system dysfunction. Increased severity, frequency, and duration of upper and lower respiratory tract infections have been reported among welders. Specifically, multiple studies have observed an excess mortality from pneumonia in welders and workers exposed to metal fumes. Although several welder cohort and experimental animal studies investigating the adverse effects of welding fume exposure on immune function have been performed, the potential mechanisms responsible for these effects are limited. The objective of this report was to review both human and animal studies that have examined the effect of welding fume pulmonary exposure on local and systemic immune responses. PMID:22734811

  4. Robin Hood Comes of Age.

    ERIC Educational Resources Information Center

    Barnhouse, Rebecca

    2003-01-01

    Considers how while some Robin Hood books are clearly intended for young readers, others blur the boundaries, sometimes in ways that help break down artificial boundaries dividing fiction for children from that for adults. Explores the legend's long history to help understand why the story lends itself to such a wide variety of retellings.…

  5. Rupture of the extensor hood of the fifth toe: a rare injury.

    PubMed

    Venturini, Sara; Gaba, Suchi; Mangwani, Jitendra

    2017-02-27

    Closed injuries of the extensor hood of the lesser toes are rare and seldom reported in the literature. We present the case of a woman aged 25 years who presented to the orthopaedic fracture clinic with a 2-week history of pain in the left fifth toe and inability to extend following a ballet dancing session. Investigations showed no fracture on plain radiographs, but an ultrasound scan demonstrated rupture to the extensor hood of the little toe. Successful surgical repair of the extensor hood was performed, and the patient made a good recovery with return to dancing activities. 2017 BMJ Publishing Group Ltd.

  6. Digital Data for Volcano Hazards of the Mount Hood Region, Oregon

    USGS Publications Warehouse

    Schilling, S.P.; Doelger, S.; Scott, W.E.; Pierson, T.C.; Costa, J.E.; Gardner, C.A.; Vallance, J.W.; Major, J.J.

    2008-01-01

    Snow-clad Mount Hood dominates the Cascade skyline from the Portland metropolitan area to the wheat fields of Wasco and Sherman Counties. The mountain contributes valuable water, scenic, and recreational resources that help sustain the agricultural and tourist segments of the economies of surrounding cities and counties. Mount Hood is also one of the major volcanoes of the Cascade Range, having erupted repeatedly for hundreds of thousands of years, most recently during two episodes in the past 1,500 yr. The last episode ended shortly before the arrival of Lewis and Clark in 1805. When Mount Hood erupts again, it will severely affect areas on its flanks and far downstream in the major river valleys that head on the volcano. Volcanic ash may fall on areas up to several hundred kilometers downwind. The purpose of the volcano hazard report USGS Open-File Report 97-89 (Scott and others, 1997) is to describe the kinds of hazardous geologic events that have happened at Mount Hood in the past and to show which areas will be at risk when such events occur in the future. This data release contains the geographic information system (GIS) data layers used to produce the Mount Hood volcano hazard map in USGS Open-File Report 97-89. Both proximal and distal hazard zones were delineated by scientists at the Cascades Volcano Observatory and depict various volcano hazard areas around the mountain. A second data layer contains points that indicate estimated travel times of lahars.

  7. Lack of formation of heterocyclic amines in fumes from frying French fries.

    PubMed

    Hsu, H Y; Inbaraj, B Stephen; Chen, B H

    2006-09-01

    The formation of heterocyclic amines (HAs) in the fumes from frying French fries in soybean oil or lard was studied. A high-pressure liquid chromatography method was used to determine the various HAs in fumes. Results showed that the yields of fumes produced from soybean oil when heated alone for 2 or 4 h were higher than from lard; however, a reversed trend was found when frying French fries in soybean oil and lard. Most fumes from soybean oil and lard while frying French fries were adsorbed onto the condensation apparatus, while the other portions were adsorbed onto the wool and glass beads, which were incorporated in our experimental design for collecting the fumes. The fumes from soybean oil when heated alone were found to contain three HAs, namely, 2-amino-3-methylimidazo[4,5-f]quinoxaline (IQx), 2-amino-3-methylimidazo[4,5-f ]quinoline (IQ), and 1-methyl-9H-pyrido[4,3-b ]indole (Harman), whereas two more HAs, 2-amino-3,4-dimethylimidazo[4,5-f]quinoline (MeIQ) and 3-amino-1,4-dimethyl-5H-pyrido[4,3-b ]indole (Trp-P-1), were generated in lard. Lard was more susceptible to the formation of HAs than soybean oil when both were heated alone. No HAs were detected in the fumes from French fries fried in soybean oil and lard.

  8. deFUME: Dynamic exploration of functional metagenomic sequencing data.

    PubMed

    van der Helm, Eric; Geertz-Hansen, Henrik Marcus; Genee, Hans Jasper; Malla, Sailesh; Sommer, Morten Otto Alexander

    2015-07-31

    Functional metagenomic selections represent a powerful technique that is widely applied for identification of novel genes from complex metagenomic sources. However, whereas hundreds to thousands of clones can be easily generated and sequenced over a few days of experiments, analyzing the data is time consuming and constitutes a major bottleneck for experimental researchers in the field. Here we present the deFUME web server, an easy-to-use web-based interface for processing, annotation and visualization of functional metagenomics sequencing data, tailored to meet the requirements of non-bioinformaticians. The web-server integrates multiple analysis steps into one single workflow: read assembly, open reading frame prediction, and annotation with BLAST, InterPro and GO classifiers. Analysis results are visualized in an online dynamic web-interface. The deFUME webserver provides a fast track from raw sequence to a comprehensive visual data overview that facilitates effortless inspection of gene function, clustering and distribution. The webserver is available at cbs.dtu.dk/services/deFUME/and the source code is distributed at github.com/EvdH0/deFUME.

  9. Response of the mouse lung transcriptome to welding fume: effects of stainless and mild steel fumes on lung gene expression in A/J and C57BL/6J mice.

    PubMed

    Zeidler-Erdely, Patti C; Kashon, Michael L; Li, Shengqiao; Antonini, James M

    2010-06-03

    Debate exists as to whether welding fume is carcinogenic, but epidemiological evidence suggests that welders are an at risk population for the development of lung cancer. Recently, we found that exposure to welding fume caused an acutely greater and prolonged lung inflammatory response in lung tumor susceptible A/J versus resistant C57BL/6J (B6) mice and a trend for increased tumor incidence after stainless steel (SS) fume exposure. Here, our objective was to examine potential strain-dependent differences in the regulation and resolution of the lung inflammatory response induced by carcinogenic (Cr and Ni abundant) or non-carcinogenic (iron abundant) metal-containing welding fumes at the transcriptome level. Mice were exposed four times by pharyngeal aspiration to 5 mg/kg iron abundant gas metal arc-mild steel (GMA-MS), Cr and Ni abundant GMA-SS fume or vehicle and were euthanized 4 and 16 weeks after the last exposure. Whole lung microarray using Illumina Mouse Ref-8 expression beadchips was done. Overall, we found that tumor susceptibility was associated with a more marked transcriptional response to both GMA-MS and -SS welding fumes. Also, Ingenuity Pathway Analysis revealed that gene regulation and expression in the top molecular networks differed between the strains at both time points post-exposure. Interestingly, a common finding between the strains was that GMA-MS fume exposure altered behavioral gene networks. In contrast, GMA-SS fume exposure chronically upregulated chemotactic and immunomodulatory genes such as CCL3, CCL4, CXCL2, and MMP12 in the A/J strain. In the GMA-SS-exposed B6 mouse, genes that initially downregulated cellular movement, hematological system development/function and immune response were involved at both time points post-exposure. However, at 16 weeks, a transcriptional switch to an upregulation for neutrophil chemotactic genes was found and included genes such as S100A8, S100A9 and MMP9. Collectively, our results demonstrate that

  10. Metabolomic characterization of laborers exposed to welding fumes.

    PubMed

    Wang, Kuo-Ching; Kuo, Ching-Hua; Tian, Tze-Feng; Tsai, Mong-Hsun; Chiung, Yin-Mei; Hsiech, Chun-Ming; Tsai, Sung-Jeng; Wang, San-Yuan; Tsai, Dong-Ming; Huang, Chiang-Ching; Tseng, Y Jane

    2012-03-19

    The complex composition of welding fumes, multiplicity of molecular targets, diverse cellular effects, and lifestyles associated with laborers vastly complicate the assessment of welding fume exposure. The urinary metabolomic profiles of 35 male welders and 16 male office workers at a Taiwanese shipyard were characterized via (1)H NMR spectroscopy and pattern recognition methods. Blood samples for the same 51 individuals were also collected, and the expression levels of the cytokines and other inflammatory markers were examined. This study dichotomized the welding exposure variable into high (welders) versus low (office workers) exposures to examine the differences of continuous outcome markers-metabolites and inflammatory markers-between the two groups. Fume particle assessments showed that welders were exposed to different concentrations of chromium, nickel, and manganese particles. Multivariate statistical analysis of urinary metabolomic patterns showed higher levels of glycine, taurine, betaine/TMAO, serine, S-sulfocysteine, hippurate, gluconate, creatinine, and acetone and lower levels of creatine among welders, while only TNF-α was significantly associated with welding fume exposure among all cytokines and other inflammatory markers measured. Of the identified metabolites, the higher levels of glycine, taurine, and betaine among welders were suspected to play some roles in modulating inflammatory and oxidative tissue injury processes. In this metabolomics experiment, we also discovered that the association of the identified metabolites with welding exposure was confounded by smoking, but not with drinking, which is a finding consistent with known modified response of inflammatory markers among smokers. Our results correspond with prior studies that utilized nonmetabolomic analytical techniques and suggest that the metabolomic profiling is an efficient method to characterize the overall effect of welding fume exposure and other confounders. © 2012 American

  11. Mutagenicity of fume particles from stainless steel welding.

    PubMed

    Hedenstedt, A; Jenssen, D; Lidestein B-M; Ramel, C; Rannug, U; Stern, R M

    1977-12-01

    Welding fume particles collected from different welding procedures were tested for mutagenicity in Escherichia coli, with the inhibition zone in pol A- as compared to pol A+, and in Salmonella typhimurium, TA 100 strain. While no mutagenicity was found with mild steel welding, a mutagenic effect was established with samples from stainless steel welding. This mutagenicity was particularly associated with manual metal arc (MMA) welding, and less so with metal inert-gas welding. A decrease in or an elimination of the effect occurred with a liver microsomal metabolizing system (S-9 mix). The MMA samples produced the strongest mutagenic effect. More-detailed investigations on these samples showed that the mutagenic agent(s) is water soluble. An increased mutagenicity, which also revealed the induction of frame shift mutations, was found with TA 98. The same welding fume sample was used for a mutagenicity test (resistance to 6-thioguanine) with V 79 hamster cells. Because of the high toxicity of these welding fume particles on the cells, only very low concentrations could be tested, but the increase of mutations, when compared to the negative control, was significant. It is suggested that hexavalent chromium may be involved in the mutagenic effect of the welding fumes.

  12. Pneumotoxicity and pulmonary clearance of different welding fumes after intratracheal instillation in the rat.

    PubMed

    Antonini, J M; Krishna Murthy, G G; Rogers, R A; Albert, R; Ulrich, G D; Brain, J D

    1996-09-01

    The objectives of this study were to compare different welding fumes in regard to their potential to elicit lung inflammation or injury and to examine possible mechanisms whereby welding fumes may damage the lungs. Fume was collected on filters from conventional spray [mild steel (MS-SPRAY) or stainless steel (SS-SPRAY) electrode wire] or pulsed current [mild steel (MS-PULSE) electrode wire] gas-shielded metal arc welding. Rats were given one of the three welding fume samples by intratracheal instillation (1.0 mg/100 g body wt). Other rats received a relatively inert dust (iron oxide), a pneumotoxic dust (crystalline silica), or a vehicle control (saline). Bronchoalveolar lavage (BAL) was performed 1, 7, 14, and 35 days postinstillation, and indicators of pulmonary damage [cellular differential, albumin, as well as, tumor necrosis factor-alpha (TNF-alpha), interleukin-1 beta (IL-1 beta), lactate dehydrogenase, and beta-n-acetyl glucosaminidase release] were assessed. One day postinstillation, some evidence of lung inflammation (more neutrophils) was observed for all particle groups, while increased BAL TNF-alpha and IL-1 beta were observed only in the SS-SPRAY and silica groups. By 14 days, lungs appeared normal among the MS-SPRAY, MS-PULSE, and iron oxide groups. At 14 and 35 days postinstillation, elevated pulmonary responses persisted for the animals exposed to silica and the SS-SPRAY welding fume. By 35 days, however, the SS-SPRAY group approached control levels, while the injury induced by silica increased. Using magnetometric estimates of welding fumes, we observed that MS-SPRAY fume was cleared from the lungs at a faster rate than the SS-SPRAY particles. We have demonstrated that the SS-SPRAY fume has more pneumotoxicity than MS fumes. This difference may reflect a greater retention of the SS-SPRAY particles in the lungs and different elemental composition of the fume. The SS-SPRAY fume also had enhanced release of TNF-alpha and IL-1 beta from lung cells

  13. Rapid Detection of Transition Metals in Welding Fumes Using Paper-Based Analytical Devices

    PubMed Central

    Volckens, John

    2014-01-01

    Metals in particulate matter (PM) are considered a driving factor for many pathologies. Despite the hazards associated with particulate metals, personal exposures for at-risk workers are rarely assessed due to the cost and effort associated with monitoring. As a result, routine exposure assessments are performed for only a small fraction of the exposed workforce. The objective of this research was to evaluate a relatively new technology, microfluidic paper-based analytical devices (µPADs), for measuring the metals content in welding fumes. Fumes from three common welding techniques (shielded metal arc, metal inert gas, and tungsten inert gas welding) were sampled in two welding shops. Concentrations of acid-extractable Fe, Cu, Ni, and Cr were measured and independently verified using inductively coupled plasma-optical emission spectroscopy (ICP-OES). Results from the µPAD sensors agreed well with ICP-OES analysis; the two methods gave statistically similar results in >80% of the samples analyzed. Analytical costs for the µPAD technique were ~50 times lower than market-rate costs with ICP-OES. Further, the µPAD method was capable of providing same-day results (as opposed several weeks for ICP laboratory analysis). Results of this work suggest that µPAD sensors are a viable, yet inexpensive alternative to traditional analytic methods for transition metals in welding fume PM. These sensors have potential to enable substantially higher levels of hazard surveillance for a given resource cost, especially in resource-limited environments. PMID:24515892

  14. Rapid detection of transition metals in welding fumes using paper-based analytical devices.

    PubMed

    Cate, David M; Nanthasurasak, Pavisara; Riwkulkajorn, Pornpak; L'Orange, Christian; Henry, Charles S; Volckens, John

    2014-05-01

    Metals in particulate matter (PM) are considered a driving factor for many pathologies. Despite the hazards associated with particulate metals, personal exposures for at-risk workers are rarely assessed due to the cost and effort associated with monitoring. As a result, routine exposure assessments are performed for only a small fraction of the exposed workforce. The objective of this research was to evaluate a relatively new technology, microfluidic paper-based analytical devices (µPADs), for measuring the metals content in welding fumes. Fumes from three common welding techniques (shielded metal arc, metal inert gas, and tungsten inert gas welding) were sampled in two welding shops. Concentrations of acid-extractable Fe, Cu, Ni, and Cr were measured and independently verified using inductively coupled plasma-optical emission spectroscopy (ICP-OES). Results from the µPAD sensors agreed well with ICP-OES analysis; the two methods gave statistically similar results in >80% of the samples analyzed. Analytical costs for the µPAD technique were ~50 times lower than market-rate costs with ICP-OES. Further, the µPAD method was capable of providing same-day results (as opposed several weeks for ICP laboratory analysis). Results of this work suggest that µPAD sensors are a viable, yet inexpensive alternative to traditional analytic methods for transition metals in welding fume PM. These sensors have potential to enable substantially higher levels of hazard surveillance for a given resource cost, especially in resource-limited environments.

  15. Reduction of cooking oil fume exposure following an engineering intervention in Chinese restaurants.

    PubMed

    Pan, Chih-Hong; Shih, Tung-Sheng; Chen, Chiou-Jong; Hsu, Jin-Huei; Wang, Shun-Chih; Huang, Chien-Ping; Kuo, Ching-Tang; Wu, Kuen-Yuh; Hu, Howard; Chan, Chang-Chuan

    2011-01-01

    A new engineering intervention measure, an embracing air curtain device (EACD), was used to increase the capture efficiency of cooker hoods and reduce cooking oil fume (COF) exposure in Chinese restaurants. An EACD was installed in six Chinese restaurants where the cooks complained of COF exposure. Before- and after-installation measurements were taken to compare changes in particulate matter (PM) and polycyclic aromatic hydrocarbons (PAHs) in kitchen air, and changes in levels of urinary 8-hydroxy-2'-deoxyguanosine (8-OHdG) and malondialdehyde (MDA). The association between PM and PAHs in air and 8-OHdG and MDA in urine was evaluated by linear mixed-effects regression analysis. Results showed that geometric mean kitchen air levels of PM(10), PM(2.5), PM(1.0) and total particulate PAHs were significantly reduced after the EACDs were introduced. Urinary levels of 8-OHdG and MDA in cooks were also significantly lower after EACD instalment. PM(2.5), PM(1.0) and benzo(a)pyrene (BaP) levels were positively associated with urinary 8-OHdG levels after adjusting for key personal covariates. Urinary MDA levels in cooks were also positively associated with BaP levels after adjusting for key personal covariates. This study demonstrates that the EACD is effective for reducing COF and oxidative stress levels in cooks working in Chinese kitchens.

  16. Kinetics of the metal components of intratracheally instilled stainless steel welding fume suspensions in rats.

    PubMed

    Kalliomäki, P L; Hyvärinen, H K; Aitio, A; Lakoma, E L; Kalliomäki, K

    1986-02-01

    The kinetics of iron, chromium, nickel, and cobalt from manual metal arc and metal inert gas stainless steel welding fumes were studied. Neutron activated welding fumes, in aqueous suspensions, were instilled intratracheally into rats. The follow up continued for up to 106 days. From both fumes, approximately 10% of the injection bolus was immediately lost into the gastrointestinal tract, to be recovered in the faeces within three days. Thereafter, a pronounced difference was seen in the kinetics of the two types of fumes. After the first day, chromium, nickel, and iron were lost from the lungs with half times of about 53, 49, and 73 days after exposure to MMA/SS fumes, whereas practically no loss could be seen in the metal components of the metal inert gas welding fumes within two months. The disposition of chromium from MMA/SS fumes closely resembled that of intratracheally instilled water soluble chromates. On the other hand, the disappearance of trivalent chromium from MIS/SS fumes was considerably slower than that of the practically water insoluble chromates, or even of trivalent chromium salts. Thus the physical characteristics of the fume appreciably affect the kinetics of the clearance of chromium compounds from the lungs.

  17. Kinetics of the metal components of intratracheally instilled stainless steel welding fume suspensions in rats.

    PubMed Central

    Kalliomäki, P L; Hyvärinen, H K; Aitio, A; Lakoma, E L; Kalliomäki, K

    1986-01-01

    The kinetics of iron, chromium, nickel, and cobalt from manual metal arc and metal inert gas stainless steel welding fumes were studied. Neutron activated welding fumes, in aqueous suspensions, were instilled intratracheally into rats. The follow up continued for up to 106 days. From both fumes, approximately 10% of the injection bolus was immediately lost into the gastrointestinal tract, to be recovered in the faeces within three days. Thereafter, a pronounced difference was seen in the kinetics of the two types of fumes. After the first day, chromium, nickel, and iron were lost from the lungs with half times of about 53, 49, and 73 days after exposure to MMA/SS fumes, whereas practically no loss could be seen in the metal components of the metal inert gas welding fumes within two months. The disposition of chromium from MMA/SS fumes closely resembled that of intratracheally instilled water soluble chromates. On the other hand, the disappearance of trivalent chromium from MIS/SS fumes was considerably slower than that of the practically water insoluble chromates, or even of trivalent chromium salts. Thus the physical characteristics of the fume appreciably affect the kinetics of the clearance of chromium compounds from the lungs. PMID:3947567

  18. 76 FR 70649 - Safety Zone; Department of Defense Exercise, Hood Canal, WA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-15

    ...-AA00 Safety Zone; Department of Defense Exercise, Hood Canal, WA AGENCY: Coast Guard, DHS. ACTION... involved in a Department of Defense exercise in Hood Canal, WA that will take place on November 21, 2011. A... would end. These Department of Defense (DOD) vessels have an important and urgent need to perform this...

  19. A comparison between atmospheric/humidity and vacuum cyanoacrylate fuming of latent fingermarks.

    PubMed

    Farrugia, Kevin J; Fraser, Joanna; Friel, Lauren; Adams, Duncan; Attard-Montalto, Nicola; Deacon, Paul

    2015-12-01

    A number of pseudo-operational trials were set up to compare the atmospheric/humidity and vacuum cyanoacrylate fuming processes on plastic carrier bags. The fuming processes were compared using two-step cyanoacrylate fuming with basic yellow 40 (BY40) staining and a one-step fluorescent cyanoacrylate fuming, Lumicyano 4%. Preliminary work using planted fingermarks and split depletions were performed to identify the optimum vacuum fuming conditions. The first pseudo-operational trial compared the different fuming conditions (atmospheric/humidity vs. vacuum) for the two-step process where an additional 50% more marks were detected with the atmospheric/humidity process. None of the marks by the vacuum process could be observed visually; however, a significant number of marks were detected by fluorescence after BY40 staining. The second trial repeated the same work in trial 1 using the one-step cyanoacrylate process, Lumicyano at a concentration of 4%. Trial 2 provided comparable results to trial 1 and all the items were then re-treated with Lumicyano 4% at atmospheric/humidity conditions before dyeing with BY40 to provide the sequences of process A (Lumicyano 4% atmospheric-Lumicyano 4% atmospheric-BY40) and process B (Lumicyano 4% vacuum-Lumicyano 4% atmospheric-BY40). The number of marks (visual and fluorescent) was counted after each treatment with a substantial increase in the number of detected marks in the second and third treatments of the process. The increased detection rate after the double Lumicyano process was unexpected and may have important implications. Trial 3 was performed to investigate whether the amount of cyanoacrylate and/or fuming time had an impact on the results observed in trial 2 whereas trial 4 assessed if the double process using conventional cyanoacrylate, rather than Lumicyano 4%, provided an increased detection rate. Trials 3 and 4 confirmed that doubling the amount of Lumicyano 4% cyanoacrylate and fuming time produced a lower

  20. HIGHLIGHTS FROM TECHNICAL MANUAL ON HOOD SYSTEM CAPTURE OF PROCESS FUGITIVE PARTICULATE EMISSIONS

    EPA Science Inventory

    The paper discusses a technical manual whose emphasis is on the design and evaluation of actual hood systems used to control various fugitive particulate emission sources. Engineering analyses of the most important hood types are presented to provide a conceptual understanding of...

  1. Response of the mouse lung transcriptome to welding fume: effects of stainless and mild steel fumes on lung gene expression in A/J and C57BL/6J mice

    PubMed Central

    2010-01-01

    Background Debate exists as to whether welding fume is carcinogenic, but epidemiological evidence suggests that welders are an at risk population for the development of lung cancer. Recently, we found that exposure to welding fume caused an acutely greater and prolonged lung inflammatory response in lung tumor susceptible A/J versus resistant C57BL/6J (B6) mice and a trend for increased tumor incidence after stainless steel (SS) fume exposure. Here, our objective was to examine potential strain-dependent differences in the regulation and resolution of the lung inflammatory response induced by carcinogenic (Cr and Ni abundant) or non-carcinogenic (iron abundant) metal-containing welding fumes at the transcriptome level. Methods Mice were exposed four times by pharyngeal aspiration to 5 mg/kg iron abundant gas metal arc-mild steel (GMA-MS), Cr and Ni abundant GMA-SS fume or vehicle and were euthanized 4 and 16 weeks after the last exposure. Whole lung microarray using Illumina Mouse Ref-8 expression beadchips was done. Results Overall, we found that tumor susceptibility was associated with a more marked transcriptional response to both GMA-MS and -SS welding fumes. Also, Ingenuity Pathway Analysis revealed that gene regulation and expression in the top molecular networks differed between the strains at both time points post-exposure. Interestingly, a common finding between the strains was that GMA-MS fume exposure altered behavioral gene networks. In contrast, GMA-SS fume exposure chronically upregulated chemotactic and immunomodulatory genes such as CCL3, CCL4, CXCL2, and MMP12 in the A/J strain. In the GMA-SS-exposed B6 mouse, genes that initially downregulated cellular movement, hematological system development/function and immune response were involved at both time points post-exposure. However, at 16 weeks, a transcriptional switch to an upregulation for neutrophil chemotactic genes was found and included genes such as S100A8, S100A9 and MMP9. Conclusions

  2. Comparison of stainless and mild steel welding fumes in generation of reactive oxygen species.

    PubMed

    Leonard, Stephen S; Chen, Bean T; Stone, Samuel G; Schwegler-Berry, Diane; Kenyon, Allison J; Frazer, David; Antonini, James M

    2010-11-03

    Welding fumes consist of a wide range of complex metal oxide particles which can be deposited in all regions of the respiratory tract. The welding aerosol is not homogeneous and is generated mostly from the electrode/wire. Over 390,000 welders were reported in the U.S. in 2008 while over 1 million full-time welders were working worldwide. Many health effects are presently under investigation from exposure to welding fumes. Welding fume pulmonary effects have been associated with bronchitis, metal fume fever, cancer and functional changes in the lung. Our investigation focused on the generation of free radicals and reactive oxygen species from stainless and mild steel welding fumes generated by a gas metal arc robotic welder. An inhalation exposure chamber located at NIOSH was used to collect the welding fume particles. Our results show that hydroxyl radicals (.OH) were generated from reactions with H2O2 and after exposure to cells. Catalase reduced the generation of .OH from exposed cells indicating the involvement of H2O2. The welding fume suspension also showed the ability to cause lipid peroxidation, effect O2 consumption, induce H2O2 generation in cells, and cause DNA damage. Increase in oxidative damage observed in the cellular exposures correlated well with .OH generation in size and type of welding fumes, indicating the influence of metal type and transition state on radical production as well as associated damage. Our results demonstrate that both types of welding fumes are able to generate ROS and ROS-related damage over a range of particle sizes; however, the stainless steel fumes consistently showed a significantly higher reactivity and radical generation capacity. The chemical composition of the steel had a significant impact on the ROS generation capacity with the stainless steel containing Cr and Ni causing more damage than the mild steel. Our results suggest that welding fumes may cause acute lung injury. Since type of fume generated, particle size

  3. Comparison of stainless and mild steel welding fumes in generation of reactive oxygen species

    PubMed Central

    2010-01-01

    Background Welding fumes consist of a wide range of complex metal oxide particles which can be deposited in all regions of the respiratory tract. The welding aerosol is not homogeneous and is generated mostly from the electrode/wire. Over 390,000 welders were reported in the U.S. in 2008 while over 1 million full-time welders were working worldwide. Many health effects are presently under investigation from exposure to welding fumes. Welding fume pulmonary effects have been associated with bronchitis, metal fume fever, cancer and functional changes in the lung. Our investigation focused on the generation of free radicals and reactive oxygen species from stainless and mild steel welding fumes generated by a gas metal arc robotic welder. An inhalation exposure chamber located at NIOSH was used to collect the welding fume particles. Results Our results show that hydroxyl radicals (.OH) were generated from reactions with H2O2 and after exposure to cells. Catalase reduced the generation of .OH from exposed cells indicating the involvement of H2O2. The welding fume suspension also showed the ability to cause lipid peroxidation, effect O2 consumption, induce H2O2 generation in cells, and cause DNA damage. Conclusion Increase in oxidative damage observed in the cellular exposures correlated well with .OH generation in size and type of welding fumes, indicating the influence of metal type and transition state on radical production as well as associated damage. Our results demonstrate that both types of welding fumes are able to generate ROS and ROS-related damage over a range of particle sizes; however, the stainless steel fumes consistently showed a significantly higher reactivity and radical generation capacity. The chemical composition of the steel had a significant impact on the ROS generation capacity with the stainless steel containing Cr and Ni causing more damage than the mild steel. Our results suggest that welding fumes may cause acute lung injury. Since type of

  4. [Determination of fumes and their elements from flux cored arc welding].

    PubMed

    Matczak, Wanda; Przybylska-Stanisławska, Magdalena

    2004-01-01

    The aim of this work was to assay the concentration levels and composition of welding fumes, released during flux cored arc welding, to assess exposure of welders. Concentrations and welding fume components, such as iron, manganese, chromium (including the soluble and chromium VI), nickel, copper, calcium, aluminium, barium, and fluorides (including hydrogen fluoride) were determined in the air of six industrial plants (shipyards, mechanical engineering plants and a power station) at the breathing zones of the welders who used 10 types of wires during flux cored arc welding. The following determination methods were used: gravimetry (fumes), AAS (metals), and spectrophotometry (chromium VI, fluorides--including hydrogen fluoride). The results made it possible to determine the relationship between concentrations of welding fume and its elements, and to assess worker's exposure. Time weighted average concentrations of the welding fumes and its elements at the worker's breathing zone were: mg/m3: dust 0.2-24.3; Fe 0.2-6.7; Mn 0.01-1.8; Cr 0.004-0.5 (mainly Cr III); Ca 0.004-2.5; Ni < or = 0.004; Cu < 0.002-0.05; Al < 0.14-0.4; Ba < 0.14; F- 0.07-0.43. The welders using some types of flux cored welding wires worked in conditions harmful to their health owing to the considerably exceeded TLV value for fume and MAC values for manganese, and occasional slightly excessive MAC values for calcium and iron.

  5. Silica Fume Functionalized With Amine-Based Additives as a Modifier to Enhance Asphalt Resistance to Oxidation

    NASA Astrophysics Data System (ADS)

    Abutalib, Nader Turki

    This dissertation investigates the practical feasibility of functionalizing silica fume particles with the amine groups in Bio-binder and pure APTES chemical to disperse silica fume in asphalt binder matrix to produce silica-fume-modified binder (SFMB). Dispersed silica fume was then introduced to asphalt to reduce oxidative aging. It has been widely reported that asphalt binder oxidation is one of the phenomena that reduces the service life of asphalt pavement by negatively affecting its rheological properties. This in turn can lead to a more brittle pavement, which is more prone to cracks due to thermal stress and traffic loading. It has been shown that the introduction of 4% silica fume to asphalt can reduce asphalt oxidative aging. However, the challenge with a higher percentage of silica fume was found to be the agglomeration of nano- particles to form micro-size clusters, which can reduce the effectiveness of silica fume while making asphalt binder more susceptible to shear. Therefore, this dissertation studies the effectiveness of functionalizing the SFMB to reduce asphalt oxidative aging while alleviating the agglomeration effect. To do so, various percentages of bio-binder (BB) and bio-char (BC) were introduced to SFMB, and the rheological properties and high-temperature performance of each specimen were evaluated by measuring the rotational viscosity and complex shear modulus before and after oxidative aging. It is hypothesized that fine-graded BC and BB with nano- to micro-level particles can be used to reduce asphalt oxidation and create a new generation of low- agglomeration SFMB with higher resistance to oxidative aging. To further study the effects of functionalization on dispersion of silica fume, silica fume particles were produced with different functional groups: amine (APTES) groups and phosphonate (THPMP) groups. Agglomeration studies using a scanning electron microscope and zeta potential analysis indicate that modifying asphalt binder with

  6. Peripheral neuropathy following intentional inhalation of naphtha fumes.

    PubMed Central

    Tenenbein, M; deGroot, W; Rajani, K R

    1984-01-01

    Two adolescent native Canadians who presented with peripheral neuropathy secondary to the abuse of volatile hydrocarbons are described. They were initially thought to have been sniffing leaded gasoline fumes, but public health investigation revealed that they had been sniffing naphtha fumes. Naphtha contains a significant amount of n-hexane, a known inducer of neuropathy. Nerve conduction studies and nerve biopsy confirmed the diagnosis of naphtha abuse. These cases emphasize the need to specifically identify the formulation of hydrocarbons being abused. PMID:6093978

  7. Estimation of regional pulmonary deposition and exposure for fumes from SMAW and GMAW mild and stainless steel consumables.

    PubMed

    Hewett, P

    1995-02-01

    The particle size distributions and bulk fume densities for mild steel and stainless steel welding fumes generated using two welding processes (shielded metal arc welding [SMAW] and gas metal arc welding [GMAW]) were used in mathematical models to estimate regional pulmonary deposition (the fraction of each fume expected to deposit in each region of the pulmonary system) and regional pulmonary exposure (the fraction of each fume expected to penetrate to each pulmonary region and would be collected by a particle size-selective sampling device). Total lung deposition for GMAW fumes was estimated at 60% greater than that of SMAW fumes. Considering both the potential for deposition and the fume specific surface areas, it is likely that for equal exposure concentrations GMAW fumes deliver nearly three times the particle surface area to the lungs as SMAW fumes. This leads to the hypothesis that exposure to GMAW fumes constitutes a greater pulmonary hazard than equal exposure to SMAW fumes. The implications of this hypothesis regarding the design of future health studies of welders is discussed.

  8. Ecological Baseline, Fort Hood, Texas

    DTIC Science & Technology

    1980-08-01

    cedar eTm (Uiimus crassifolia), Texas ash (Fraxinus texansis), and Texas persimmon ( Diospyros texana). Conversely, the two predominant tree species...Ilex decidua), Mex- ican buckeye (Ungnadia spjeciosa), and Texas persimmon ( Diospyros texana). Vines included greenbrier (Smilax bona-nox) and white...Hedgehey Cactus (Echinocereus sp.) has been observed on Fort Hood. Due to the brief period of flowering for this genus , the individual species were not

  9. Equipment & New Products

    ERIC Educational Resources Information Center

    Poitras, Adrian W., Ed.

    1976-01-01

    Listed are a number of materials including a spectrophotometer, power meter, vacuum pump, fume hood, cart system, and others. The source of the product and a brief description are given for each. (RH)

  10. Comparative microscopic study of human and rat lungs after overexposure to welding fume.

    PubMed

    Antonini, James M; Roberts, Jenny R; Schwegler-Berry, Diane; Mercer, Robert R

    2013-11-01

    Welding is a common industrial process used to join metals and generates complex aerosols of potentially hazardous metal fumes and gases. Most long-time welders experience some type of respiratory disorder during their time of employment. The use of animal models and the ability to control the welding fume exposure in toxicology studies have been helpful in developing a better understanding of how welding fumes affect health. There are no studies that have performed a side-by-side comparison of the pulmonary responses from an animal toxicology welding fume study with the lung responses associated with chronic exposure to welding fume by a career welder. In this study, post-mortem lung tissue was donated from a long-time welder with a well-characterized work background and a history of extensive welding fume exposure. To simulate a long-term welding exposure in an animal model, Sprague-Dawley rats were treated once a week for 28 weeks by intratracheal instillation with 2mg of a stainless steel, hard-surfacing welding fume. Lung tissues from the welder and the welding fume-treated rats were examined by light and electron microscopy. Pathological analysis of lung tissue collected from the welder demonstrated inflammatory cell influx and significant pulmonary injury. The poor and deteriorating lung condition observed in the welder examined in this study was likely due to exposure to very high levels of potentially toxic metal fumes and gases for a significant number of years due to work in confined spaces. The lung toxicity profile for the rats treated with welding fume was similar. For tissue samples from both the welder and treated rats, welding particle accumulations deposited and persisted in lung structures and were easily visualized using light microscopic techniques. Agglomerates of deposited welding particles mostly were observed within lung cells, particularly alveolar macrophages. Analysis of individual particles within the agglomerates showed that these

  11. Comparative Microscopic Study of Human and Rat Lungs After Overexposure to Welding Fume

    PubMed Central

    ANTONINI, JAMES M.; ROBERTS, JENNY R.; SCHWEGLER-BERRY, DIANE; MERCER, ROBERT R.

    2015-01-01

    Welding is a common industrial process used to join metals and generates complex aerosols of potentially hazardous metal fumes and gases. Most long-time welders experience some type of respiratory disorder during their time of employment. The use of animal models and the ability to control the welding fume exposure in toxicology studies have been helpful in developing a better understanding of how welding fumes affect health. There are no studies that have performed a side-by-side comparison of the pulmonary responses from an animal toxicology welding fume study with the lung responses associated with chronic exposure to welding fume by a career welder. In this study, post-mortem lung tissue was donated from a long-time welder with a well-characterized work background and a history of extensive welding fume exposure. To simulate a long-term welding exposure in an animal model, Sprague-Dawley rats were treated once a week for 28 weeks by intratracheal instillation with 2 mg of a stainless steel, hard-surfacing welding fume. Lung tissues from the welder and the welding fume-treated rats were examined by light and electron microscopy. Pathological analysis of lung tissue collected from the welder demonstrated inflammatory cell influx and significant pulmonary injury. The poor and deteriorating lung condition observed in the welder examined in this study was likely due to exposure to very high levels of potentially toxic metal fumes and gases for a significant number of years due to work in confined spaces. The lung toxicity profile for the rats treated with welding fume was similar. For tissue samples from both the welder and treated rats, welding particle accumulations deposited and persisted in lung structures and were easily visualized using light microscopic techniques. Agglomerates of deposited welding particles mostly were observed within lung cells, particularly alveolar macrophages. Analysis of individual particles within the agglomerates showed that these

  12. Hooded mergansers swim in the waters of KSC

    NASA Technical Reports Server (NTRS)

    1999-01-01

    A male and two female hooded mergansers swim in the waters of the Merritt Island National Wildlife Refuge at Kennedy Space Center. The male displays its distinctive fan-shaped, black-bordered crest. Usually found from Alaska and Canada south to Nebraska, Oregon and Tennessee, hooded mergansers winter south to Mexico and the Gulf Coast, including KSC. The open water of the refuge provides wintering areas for 23 species of migratory waterfowl, as well as a year-round home for great blue herons, great egrets, wood storks, cormorants, brown pelicans and other species of marsh and shore birds. The 92,000-acre refuge is also habitat for more than 310 species of birds, 25 mammals, 117 fishes and 65 amphibians and reptiles.

  13. Flow characteristics and spillage mechanisms of an inclined quad-vortex range hood subject to influence from draft.

    PubMed

    Huang, Rong Fung; Chen, Jia-Kun; Lin, Jyun-Hua

    2015-01-01

    The flow and spillage characteristics of an inclined quad-vortex (IQV) range hood subject to the influence of drafts from various directions were studied. The laser-assisted smoke flow visualization technique was used to reveal the flow characteristics, and the tracer-gas (sulfur hexafluoride) concentration detection method was used to indicate the quantitative values of the capture efficiency of the hood. It was found that the leakage mechanisms of the IQV range hood are closely related to the flow characteristics. A critical draft velocity of about 0.5 m/s and a critical face velocity of about 0.25 m/s for the IQV range hood were found. When the IQV range hood was influenced by a draft with a velocity larger than the critical draft velocity, the spillage of pollutants became significant and the pollutant spillage rate increased with increasing draft velocity. At draft velocities less than or equal to the critical value, no containment leakages induced by the turbulence diffusion, reverse flow, or boundary-layer separation were observed, and the capture efficiency was about 100%. The IQV range hood exhibited a high ability to resist the influences of lateral and frontal drafts. The capture efficiency of the IQV range hood operated at the suction flow rate 5 to 9 m(3)/min is higher than that of the conventional range hood operated at 11 to 15 m(3)/min.

  14. 30 CFR 70.305 - Respiratory equipment; gas, dusts, fumes, or mists.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Respiratory equipment; gas, dusts, fumes, or... LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Respiratory Equipment § 70.305 Respiratory equipment; gas, dusts, fumes, or mists. Respiratory equipment approved by...

  15. 30 CFR 70.305 - Respiratory equipment; gas, dusts, fumes, or mists.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Respiratory equipment; gas, dusts, fumes, or... LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Respiratory Equipment § 70.305 Respiratory equipment; gas, dusts, fumes, or mists. Respiratory equipment approved by...

  16. 30 CFR 70.305 - Respiratory equipment; gas, dusts, fumes, or mists.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Respiratory equipment; gas, dusts, fumes, or... LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Respiratory Equipment § 70.305 Respiratory equipment; gas, dusts, fumes, or mists. Respiratory equipment approved by...

  17. 30 CFR 70.305 - Respiratory equipment; gas, dusts, fumes, or mists.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Respiratory equipment; gas, dusts, fumes, or... LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Respiratory Equipment § 70.305 Respiratory equipment; gas, dusts, fumes, or mists. Respiratory equipment approved by...

  18. 30 CFR 70.305 - Respiratory equipment; gas, dusts, fumes, or mists.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Respiratory equipment; gas, dusts, fumes, or... LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Respiratory Equipment § 70.305 Respiratory equipment; gas, dusts, fumes, or mists. Respiratory equipment approved by...

  19. Effect of welding fume solubility on lung macrophage viability and function in vitro.

    PubMed

    Antonini, J M; Lawryk, N J; Murthy, G G; Brain, J D

    1999-11-26

    It was shown previously that fumes generated from stainless steel (SS) welding induced more pneumotoxicity and were cleared from the lungs at a slower rate than fumes collected from mild steel (MS) welding. These differences in response may be attributed to the metal composition of SS and MS welding fumes. In this study, fumes with vastly different metal profiles were collected during gas metal arc (GMA) or flux-covered manual metal arc (MMA) welding using two different consumable electrodes, SS or MS. The collected samples were suspended in saline, incubated for 24 h at 37 degrees C, and centrifuged. The supernatant (soluble components) and pellets (insoluble particulates) were separated, and their effects on lung macrophage viability and the release of reactive oxygen species (ROS) by macrophages were examined in vitro. The soluble MMA-SS sample was shown to be the most cytotoxic to macrophages and to have the greatest effect on their function as compared to the GMA-SS and GMA-MS fumes. Neither the soluble nor insoluble forms of the GMA-MS sample had any marked effect on macrophage viability. The flux-covered MMA-SS fume was found to be much more water soluble as compared to either the GMA-SS or the GMA-MS fumes. The soluble fraction of the MMA-SS samples was comprised almost entirely of Cr. The small fraction of the GMA-MS sample that was soluble contained Mn with little Fe, while a more complex mixture was observed in the soluble portion of the GMA-SS sample, which contained Mn, Ni, Fe, Cr, and Cu. Data show that differences in the solubility of welding fumes influence the viability and ROS production of macrophages. The presence of soluble metals, such as Fe, Cr, Ni, Cu, and Mn, and the complexes formed by these different metals are likely important in the pulmonary responses observed after welding fume exposure.

  20. In vitro toxicity of welding fumes and their constituents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stern, R.M.; Hansen, K.; Madsen, A.F.

    1988-08-01

    Welding fumes from a wide variety of processes and applications were assayed for toxicity with BHK21 cell line and SHE primary cells in culture. The most toxic fumes are those from the manual metal arc welding of stainless steel (MMA/SS) (LD50 = 7-14 microgram/ml), although all other welding fumes tested are toxic, with potencies lower by a factor of 10-200. The activity of MMA/SS is presumably due to the presence of high concentrations of Cr(VI) in the soluble fraction: For all other fumes the lowered activity (LD50 = 80-800 microgram/ml) is limited mostly to the insoluble fraction, and in partmore » can be related to the presence of MnO/sub 2/ and Fe/sub 3/O/sub 4/ which are toxic at such levels in these cell culture assays. Slight discrepancies between survival tests for the two cell lines, and between survival and lactate dehydrogenate release for BHK, indicate a differential response to certain constituents of these complex materials. These results suggest the need for a battery of different types of assays for use in an eventual ranking of exposures for the purpose of relative risk assessment.« less

  1. 33 CFR 165.1339 - Safety Zone; Coast Guard Exercise Area, Hood Canal, Washington.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Safety Zone; Coast Guard Exercise... § 165.1339 Safety Zone; Coast Guard Exercise Area, Hood Canal, Washington. (a) Location. The following... Coast Guard training exercise while such vessel is transiting Hood Canal, WA between Foul Weather Bluff...

  2. 33 CFR 165.1339 - Safety Zone; Coast Guard Exercise Area, Hood Canal, Washington.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Safety Zone; Coast Guard Exercise... § 165.1339 Safety Zone; Coast Guard Exercise Area, Hood Canal, Washington. (a) Location. The following... Coast Guard training exercise while such vessel is transiting Hood Canal, WA between Foul Weather Bluff...

  3. 'Cobra Hoods' Coming At You

    NASA Technical Reports Server (NTRS)

    2004-01-01

    This 3-D image taken by the left and right eyes of the panoramic camera on the Mars Exploration Rover Spirit shows the odd rock formation dubbed 'Cobra Hoods' (center). Rover scientists say this resistant rock is unlike anything they've seen on Mars so far. Spirit will investigate the rock in coming sols. The stereo pictures making up this image were captured on sol 156 (June 11, 2004).

  4. Recurrent exposure to welding fumes induces insufficient recovery from inflammation.

    PubMed

    Yang, Mi Jin; Yang, Young Su; Sung, Jae Hyuck; Kim, Jin Sung; Cho, Kyu Hyuk; Lim, Chae Woong; Chung, Yong Hyun; Kim, Hyeon Yeong; Yang, Jung Sun; Yu, Il Je; Song, Chang Woo

    2009-02-01

    Previous studies on welding-fume-induced lung fibrosis have indicated that recovery is possible when the degree of exposure is short-term and moderate. However, this study investigated the recovery after recurrent exposure to welding fumes, as welders are invariably re-exposed to welding fumes after recovering from radiographic pneumoconiosis. Thus, to investigate the disease and recovery processes of welding-fume-induced pneumoconiosis in the case of recurrent welding-fume exposure, rats were exposed to manual metal arc-stainless steel (MMA-SS) welding fumes with a total suspended particulate (TSP) concentration of 51.4 +/- 2.8 mg/m(3) (low dose) or 84.6 +/- 2.9 mg/m(3) (high dose) for 2 h/day in an inhalation chamber for 1 mo and then allowed to recover from the inflammation for 1 mo. Thereafter, the rats were exposed again to MMA-SS with a TSP concentration of 44.1 +/- 8.8 mg/m(3) (low dose) or 80.1 +/- 9.8 mg/m(3) (high dose) for another 30 d and then allowed to recover from the inflammation for 1 mo. The recovery from the first exposure was then compared with that from the second exposure. The first and second exposures to MMA-SS welding fumes were found to produce significant increases in the lung weights and inflammatory parameters, including total cell numbers, alveolar macrophages (AMs), polymorphonuclear cells (PMNs), lymphocytes, and lactate dehydrogenase (LDH) in the bronchoalveolar lavage fluid (BALF) when compared with the unexposed controls. Following the first and second recovery, a significant reduction in inflammatory parameters of BALF was observed between the exposure and recovery groups. Histopathological observations showed foamy or pigmented macrophage accumulation, cellular debris, or pigment from burst macrophages after the first or second exposure. Following the first or second recovery, cellular debris or pigment from burst macrophages was cleared away from the lungs and accumulation of foamy or pigmented macrophages was decreased when

  5. Inflammatory Markers in Blood and Exhaled Air after Short-Term Exposure to Cooking Fumes

    PubMed Central

    Svedahl, Sindre Rabben

    2013-01-01

    Objectives: Cooking fumes contain aldehydes, alkanoic acids, polycyclic aromatic hydrocarbons, and heterocyclic compounds. The inhalation of cooking fumes entails a risk of deleterious health effects. The aim of this study was to see if the inhalation of cooking fumes alters the expression of inflammatory reactions in the bronchial mucosa and its subsequent systemic inflammatory response in blood biomarkers. Methods: Twenty-four healthy volunteers stayed in a model kitchen on two different occasions for 2 or 4h. On the first occasion, there was only exposure to normal air, and on the second, there was exposure to controlled levels of cooking fumes. On each occasion, samples of blood, exhaled air, and exhaled breath condensate (EBC) were taken three times in 24h and inflammatory markers were measured from all samples. Results: There was an increase in the concentration of the d-dimer in blood from 0.27 to 0.28mg ml–1 on the morning after exposure to cooking fumes compared with the levels the morning before (P-value = 0.004). There was also a trend of an increase in interleukin (IL)-6 in blood, ethane in exhaled air, and IL-1β in EBC after exposure to cooking fumes. In a sub-analysis of 12 subjects, there was also an increase in the levels of ethane—from 2.83 parts per billion (ppb) on the morning before exposure to cooking fumes to 3.53 ppb on the morning after exposure (P = 0.013)—and IL-1β—from 1.04 on the morning before exposure to cooking fumes to 1.39 pg ml–1 immediately after (P = 0.024). Conclusion: In our experimental setting, we were able to unveil only small changes in the levels of inflammatory markers in exhaled air and in blood after short-term exposure to moderate concentrations of cooking fumes. PMID:23179989

  6. Modifying welding process parameters can reduce the neurotoxic potential of manganese-containing welding fumes.

    PubMed

    Sriram, Krishnan; Lin, Gary X; Jefferson, Amy M; Stone, Samuel; Afshari, Aliakbar; Keane, Michael J; McKinney, Walter; Jackson, Mark; Chen, Bean T; Schwegler-Berry, Diane; Cumpston, Amy; Cumpston, Jared L; Roberts, Jenny R; Frazer, David G; Antonini, James M

    2015-02-03

    Welding fumes (WF) are a complex mixture of toxic metals and gases, inhalation of which can lead to adverse health effects among welders. The presence of manganese (Mn) in welding electrodes is cause for concern about the potential development of Parkinson's disease (PD)-like neurological disorder. Consequently, from an occupational safety perspective, there is a critical need to prevent adverse exposures to WF. As the fume generation rate and physicochemical characteristics of welding aerosols are influenced by welding process parameters like voltage, current or shielding gas, we sought to determine if changing such parameters can alter the fume profile and consequently its neurotoxic potential. Specifically, we evaluated the influence of voltage on fume composition and neurotoxic outcome. Rats were exposed by whole-body inhalation (40 mg/m(3); 3h/day × 5 d/week × 2 weeks) to fumes generated by gas-metal arc welding using stainless steel electrodes (GMA-SS) at standard/regular voltage (25 V; RVSS) or high voltage (30 V; HVSS). Fumes generated under these conditions exhibited similar particulate morphology, appearing as chain-like aggregates; however, HVSS fumes comprised of a larger fraction of ultrafine particulates that are generally considered to be more toxic than their fine counterparts. Paradoxically, exposure to HVSS fumes did not elicit dopaminergic neurotoxicity, as monitored by the expression of dopaminergic and PD-related markers. We show that the lack of neurotoxicity is due to reduced solubility of Mn in HVSS fumes. Our findings show promise for process control procedures in developing prevention strategies for Mn-related neurotoxicity during welding; however, it warrants additional investigations to determine if such modifications can be suitably adapted at the workplace to avert or reduce adverse neurological risks. Published by Elsevier Ireland Ltd.

  7. Modifying welding process parameters can reduce the neurotoxic potential of manganese-containing welding fumes

    PubMed Central

    Sriram, Krishnan; Lin, Gary X.; Jefferson, Amy M.; Stone, Samuel; Afshari, Aliakbar; Keane, Michael J.; McKinney, Walter; Jackson, Mark; Chen, Bean T.; Schwegler-Berry, Diane; Cumpston, Amy; Cumpston, Jared L.; Roberts, Jenny R.; Frazer, David G.; Antonini, James M.

    2015-01-01

    Welding fumes (WF) are a complex mixture of toxic metals and gases, inhalation of which can lead to adverse health effects among welders. The presence of manganese (Mn) in welding electrodes is cause for concern about the potential development of Parkinson’s disease (PD)-like neurological disorder. Consequently, from an occupational safety perspective, there is a critical need to prevent adverse exposures to WF. As the fume generation rate and physicochemical characteristics of welding aerosols are influenced by welding process parameters like voltage, current or shielding gas, we sought to determine if changing such parameters can alter the fume profile and consequently its neurotoxic potential. Specifically, we evaluated the influence of voltage on fume composition and neurotoxic outcome. Rats were exposed by whole-body inhalation (40 mg/m3; 3 h/day × 5 d/week × 2 weeks) to fumes generated by gas–metal arc welding using stainless steel electrodes (GMA-SS) at standard/regular voltage (25 V; RVSS) or high voltage (30 V; HVSS). Fumes generated under these conditions exhibited similar particulate morphology, appearing as chain-like aggregates; however, HVSS fumes comprised of a larger fraction of ultrafine particulates that are generally considered to be more toxic than their ne counterparts. Paradoxically, exposure to HVSS fumes did not elicit dopaminergic neurotoxicity, as monitored by the expression of dopaminergic and PD-related markers. We show that the lack of neurotoxicity is due to reduced solubility of Mn in HVSS fumes. Our findings show promise for process control procedures in developing prevention strategies for Mn-related neurotoxicity during welding; however, it warrants additional investigations to determine if such modifications can be suitably adapted at the workplace to avert or reduce adverse neurological risks. PMID:25549921

  8. Persistence of deposited metals in the lungs after stainless steel and mild steel welding fume inhalation in rats.

    PubMed

    Antonini, James M; Roberts, Jenny R; Stone, Samuel; Chen, Bean T; Schwegler-Berry, Diane; Chapman, Rebecca; Zeidler-Erdely, Patti C; Andrews, Ronnee N; Frazer, David G

    2011-05-01

    Welding generates complex metal fumes that vary in composition. The objectives of this study were to compare the persistence of deposited metals and the inflammatory potential of stainless and mild steel welding fumes, the two most common fumes used in US industry. Sprague-Dawley rats were exposed to 40 mg/m(3) of stainless or mild steel welding fumes for 3 h/day for 3 days. Controls were exposed to filtered air. Generated fume was collected, and particle size and elemental composition were determined. Bronchoalveolar lavage was done on days 0, 8, 21, and 42 after the last exposure to assess lung injury/inflammation and to recover lung phagocytes. Non-lavaged lung samples were analyzed for total and specific metal content as a measure of metal persistence. Both welding fumes were similar in particle morphology and size. Following was the chemical composition of the fumes-stainless steel: 57% Fe, 20% Cr, 14% Mn, and 9% Ni; mild steel: 83% Fe and 15% Mn. There was no effect of the mild steel fume on lung injury/inflammation at any time point compared to air control. Lung injury and inflammation were significantly elevated at 8 and 21 days after exposure to the stainless steel fume compared to control. Stainless steel fume exposure was associated with greater recovery of welding fume-laden macrophages from the lungs at all time points compared with the mild steel fume. A higher concentration of total metal was observed in the lungs of the stainless steel welding fume at all time points compared with the mild steel fume. The specific metals present in the two fumes were cleared from the lungs at different rates. The potentially more toxic metals (e.g., Mn, Cr) present in the stainless steel fume were cleared from the lungs more quickly than Fe, likely increasing their translocation from the respiratory system to other organs.

  9. Volcano hazards in the Mount Hood region, Oregon

    USGS Publications Warehouse

    Scott, W.E.; Pierson, T.C.; Schilling, S.P.; Costa, J.E.; Gardner, C.A.; Vallance, J.W.; Major, J.J.

    1997-01-01

    Mount Hood is a potentially active volcano close to rapidly growing communities and recreation areas. The most likely widespread and hazardous consequence of a future eruption will be for lahars (rapidly moving mudflows) to sweep down the entire length of the Sandy (including the Zigzag) and White River valleys. Lahars can be generated by hot volcanic flows that melt snow and ice or by landslides from the steep upper flanks of the volcano. Structures close to river channels are at greatest risk of being destroyed. The degree of hazard decreases as height above a channel increases, but large lahars can affect areas more than 30 vertical meters (100 vertical feet) above river beds. The probability of eruption-generated lahars affecting the Sandy and White River valleys is 1-in-15 to l-in-30 during the next 30 years, whereas the probability of extensive areas in the Hood River Valley being affected by lahars is about ten times less. The accompanying volcano-hazard-zonation map outlines areas potentially at risk and shows that some areas may be too close for a reasonable chance of escape or survival during an eruption. Future eruptions of Mount Hood could seriously disrupt transportation (air, river, and highway), some municipal water supplies, and hydroelectric power generation and transmission in northwest Oregon and southwest Washington.

  10. Preparation and Characterization of Single Ion Conductors from High Surface Area Fumed Silica

    NASA Technical Reports Server (NTRS)

    Zhang, H.; Maitra, P.; Liu, B.; Wunder, S. L.; Lin, H.-P.; Salomon, M.; Hagedorn, Norman H. (Technical Monitor)

    2002-01-01

    Anions that can form dissociative salts with Li(+) have been prepared and covalently attached to high surface area fumed silica. When blended with polyethylene oxide (PEO), the functionalized fumed silica suppresses the crystallization of the PEO, provides dimensional stability, and serves as a single ion conductor. Since functionalized fumed silica is easily dispersed in common polar solvents, it can be incorporated in both the polymer electrolyte and the electrodes.

  11. Deficient prepulse inhibition of acoustic startle in Hooded-Wistar rats compared with Sprague-Dawley rats.

    PubMed

    van den Buuse, Maarten

    2003-04-01

    1. Prepulse inhibition of acoustic startle has been suggested as a model of sensorimotor gating and central sensory information processing. Prepulse inhibition is impaired in patients with schizophrenia and responses can be restored by antipsychotic drug treatment. In the present study, startle and prepulse inhibition of startle were compared in different rat strains. 2. Sprague-Dawley rats showed robust inhibition of startle responses by increasing intensities of prepulse delivered just before the startle stimulus. In contrast, at both 4 and 10 weeks of age, rats of the Hooded-Wistar line had markedly reduced prepulse inhibition, although startle responses were not different. 3. Treatment with the dopamine receptor agonist apomorphine (0.1 mg/kg) or the N-methyl-d-aspartate (NMDA) receptor antagonist MK-801 (0.1 mg/kg) caused disruption of prepulse inhibition in Sprague-Dawley rats. In Hooded-Wistar rats, apomorphine further reduced the already low level of prepulse inhibition, but MK-801 treatment had no significant effect. This suggests that the impaired prepulse inhibition in Hooded-Wistar rats could be caused by changes in glutamatergic activity and/or NMDA receptors in these rats. 4. In photocell cages, spontaneous exploratory activity and inner zone activity were significantly lower in Hooded-Wistar rats than in Sprague-Dawley rats. Similarly, on the elevated plus-maze, Hooded-Wistar rats showed a lower propensity to visit the open arms. In contrast, amphetamine (0.5 mg/kg)-induced locomotor hyperactivity, an animal model of psychosis, was enhanced in Hooded-Wistar rats. 5. These data suggest that the Hooded-Wistar line could be a useful genetic animal model to study the interaction of glutamatergic and dopaminergic mechanisms in anxiety and schizophrenia.

  12. Pulmonary toxicity and extrapulmonary tissue distribution of metals after repeated exposure to different welding fumes.

    PubMed

    Antonini, James M; Roberts, Jenny R; Chapman, Rebecca S; Soukup, Joleen M; Ghio, Andrew J; Sriram, Krishnan

    2010-08-01

    Welders are exposed to fumes with different metal profiles. The goals of this study were to compare lung responses in rats after treatment with chemically different welding fumes and to examine the extrapulmonary fate of metals after deposition in the lungs. Rats were treated by intratracheal instillation (0.5 mg/rat, once a week for 7 weeks) with gas metal arc-mild steel (GMAW-MS) or manual metal arc-hardsurfacing (MMAW-HS) welding fumes. Controls were treated with saline. At 1, 4, 35, and 105 days after the last treatment, lung injury and inflammation were measured, and elemental analysis of different organs was determined to assess metal clearance. The MMAW-HS fume was highly water-soluble and chemically more complex with higher levels of soluble Mn and Cr compared to the GMAW-MS fume. Treatments with the GMAW-MS fume had no effect on toxicity when compared with controls. The MMAW-HS fume induced significant lung damage early after treatment that remained elevated until 35 days. Metals associated with each fume sample was cleared at different rates from the lungs. Mn was cleared from the lungs at a faster rate and to a greater extent compared to the other metals over the 105-day recovery period. Mn and Cr in the MMAW-HS fume translocated from the respiratory tract and deposited in other organs. Importantly, increased deposition of Mn, but not other metals, was observed in discrete brain regions, including dopamine-rich areas (e.g., striatum and midbrain).

  13. Manganese in occupational arc welding fumes--aspects on physiochemical properties, with focus on solubility.

    PubMed

    Taube, Fabian

    2013-01-01

    Physicochemical properties, such as particle sizes, composition, and solubility of welding fumes are decisive for the bioaccessibility of manganese and thereby for the manganese cytotoxic and neurotoxic effects arising from various welding fumes. Because of the diverse results within the research on welding fume solubility, this article aims to review and discuss recent literature on physicochemical properties of gas metal arc welding, shielded metal arc welding, and flux-cored arc welding fumes, with focus on solubility properties. This article also presents a short introduction to the literature on arc welding techniques, health effects from manganese, and occupational exposure to manganese among welders.

  14. Cost and Performance Report: Innovative Welding Technologies Using Silicon Additives to Control Hazardous Air Pollutant (HAP) Emissions

    DTIC Science & Technology

    2013-08-30

    turntable inside the hood to maintain a constant weld speed, while the ER308L stainless steel wire were fed by the welding gun. Figure 2. Fume chamber...size distribution, density and specific surface area of welding fumes from SMAW and GMAW mild- steel and stainless - steel consumables, American...shipyards. It uses mild or stainless steel filler material to join pieces of metal. The intense energy expended in the welding process results in the

  15. 30 CFR 72.701 - Respiratory equipment; gas, dusts, fumes, or mists.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Respiratory equipment; gas, dusts, fumes, or... LABOR COAL MINE SAFETY AND HEALTH HEALTH STANDARDS FOR COAL MINES Miscellaneous § 72.701 Respiratory equipment; gas, dusts, fumes, or mists. Respiratory equipment approved by NIOSH under 42 CFR part 84 shall...

  16. 75 FR 1706 - Regulated Navigation Area; U.S. Navy Submarines, Hood Canal, WA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-13

    ... area (RNA) covering the Hood Canal in Washington that will be in effect whenever any U.S. Navy submarine is operating in the Hood Canal and being escorted by the Coast Guard. The RNA is necessary to help... public in general. The RNA will do so by requiring all persons and vessels located within the RNA to...

  17. A comparison of relative toxicity rankings by some small-scale laboratory tests

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Cumming, H. J.

    1977-01-01

    Small-scale laboratory tests for fire toxicity, suitable for use in the average laboratory hood, are needed for screening and ranking materials on the basis of relative toxicity. The performance of wool, cotton, and aromatic polyamide under several test procedures is presented.

  18. Reduction of Biomechanical and Welding Fume Exposures in Stud Welding

    PubMed Central

    Fethke, Nathan B.; Peters, Thomas M.; Leonard, Stephanie; Metwali, Mahmoud; Mudunkotuwa, Imali A.

    2016-01-01

    The welding of shear stud connectors to structural steel in construction requires a prolonged stooped posture that exposes ironworkers to biomechanical and welding fume hazards. In this study, biomechanical and welding fume exposures during stud welding using conventional methods were compared to exposures associated with use of a prototype system that allowed participants to weld from an upright position. The effect of base material (i.e. bare structural beam versus galvanized decking) on welding fume concentration (particle number and mass), particle size distribution, and particle composition was also explored. Thirty participants completed a series of stud welding simulations in a local apprenticeship training facility. Use of the upright system was associated with substantial reductions in trunk inclination and the activity levels of several muscle groups. Inhalable mass concentrations of welding fume (averaged over ~18min) when using conventional methods were high (18.2mg m−3 for bare beam; 65.7mg m−3 for through deck), with estimated mass concentrations of iron (7.8mg m−3 for bare beam; 15.8mg m−3 for through deck), zinc (0.2mg m−3 for bare beam; 15.8mg m−3 for through deck), and manganese (0.9mg m−3 for bare beam; 1.5mg m−3 for through deck) often exceeding the American Conference of Governmental Industrial Hygienists Threshold Limit Values (TLVs). Number and mass concentrations were substantially reduced when using the upright system, although the total inhalable mass concentration remained above the TLV when welding through decking. The average diameters of the welding fume particles for both bare beam (31±17nm) through deck conditions (34±34nm) and the chemical composition of the particles indicated the presence of metallic nanoparticles. Stud welding exposes ironworkers to potentially high levels of biomechanical loading (primarily to the low back) and welding fume. The upright system used in this study improved exposure levels during

  19. Characterisation of fume from hyperbaric welding operations

    NASA Astrophysics Data System (ADS)

    Ross, John A. S.; Semple, Sean; Duffin, Rodger; Kelly, Frank; Seldmann, Joerg; Raab, Andrea

    2009-02-01

    We report preliminary work characterising dust from hyperbaric welding trials carried out at increased pressure in a helium and oxygen atmosphere. Particle size and concentration were measured during welding. Samples for quartz and metal analysis and toxicity assessment were taken from a filter in the local fume extraction system. The residue of dust after metal extraction by nitric acid in hydrogen peroxide predominantly a non-metallic white powder assumed to be dust from welding rod coatings and thermal insulation material. Metallic analysis showed predominantly calcium, from the welding rod coating, and period 4 transition metals such as iron, manganese, magnesium and titanium (inductively coupled mass spectrometry, Agilent 7500c). The presence of zirconium indicated a contribution from grinding. The fume was nanoparticulate in nature with a mean particle diameter of 20-30 nm (MSI Inc WPS 1000XP). It showed an intermediate level of oxidative potential regarding the low-molecular weight respiratory tract lining fluid antioxidants ascorbate and glutathione and caused release of the inflammatory marker IL-8 in a human lung A 549 epithelial cell culture with no indication of cytotoxicity. The study findings have strong implications for the measurement techniques needed to assess fume exposure in hyperbaric welding and the provision of respiratory protection.

  20. A Mass Spectrometer in Every Fume Hood

    NASA Astrophysics Data System (ADS)

    McBride, Ethan M.; Verbeck, Guido F.

    2018-06-01

    Since their inception, mass spectrometers have played a pivotal role in the direction and application of synthetic chemical research. The ability to develop new instrumentation to solve current analytical challenges in this area has always been at the heart of mass spectrometry, although progress has been slow at times. Herein, we briefly review the history of how mass spectrometry has been used to approach challenges in organic chemistry, how new developments in portable instrumentation and ambient ionization have been used to open novel areas of research, and how current techniques have the ability to expand on our knowledge of synthetic mechanisms and kinetics. Lastly, we discuss the relative paucity of work done in recent years to embrace the concept of improving benchtop synthetic chemistry with mass spectrometry, the disconnect between applications and fundamentals within these studies, and what hurdles still need to be overcome. [Figure not available: see fulltext.

  1. Simulation of aerosolized oil droplets capture in a range hood exhaust using coupled CFD-population balance method

    NASA Astrophysics Data System (ADS)

    Liu, Shuyuan; Zhang, Yong; Feng, Yu; Shi, Changbin; Cao, Yong; Yuan, Wei

    2018-02-01

    A coupled population balance sectional method (PBSM) coupled with computational fluid dynamics (CFD) is presented to simulate the capture of aerosolized oil droplets (AODs) in a range hood exhaust. The homogeneous nucleation and coagulation processes are modeled and simulated with this CFD-PBSM method. With the design angle, α of the range hood exhaust varying from 60° to 30°, the AODs capture increases meanwhile the pressure drop between the inlet and the outlet of the range hood also increases from 8.38Pa to 175.75Pa. The increasing inlet flow velocities also result in less AODs capture although the total suction increases due to higher flow rates to the range hood. Therefore, the CFD-PBSM method provides an insight into the formation and capture of AODs as well as their impact on the operation and design of the range hood exhaust.

  2. Formulation and characterization of date palm fibers mortar by addition of silica fume

    NASA Astrophysics Data System (ADS)

    Mokhtari, A.; Kriker, A.; Ouaggad, H.; Merad, N.

    2018-05-01

    This paper presents the results of experimental investigations of the formulated and characterization of date palm fibers mortar by addition of silica fume. The use of addition mineral is widely used in the production of cements through the world. The objective of this work is to bring our contribution to the recovery of local resources in the occurrence vegetable fibers of date palm to weak cost and from renewable source and integrate it in the filled of building. Date palm fiber are from Ouargla town in south of Algeria. Different mortar mixtures were prepared in which the cement was substitute by 10% of silica fume. The mechanical characteristics (compressive and flexural strength) of date palm fibers mortar by treatment of the matrix by the adding of silica fume were examined. The results obtained have shown that the mortar workability as well as the compressive and flexural strength decreases with increasing the silica fume replacement. The results showed that the use of silica fume enabled to evaluate the flexural strength. However, another treatment of fibers and matrix will be recommended for Improved the characteristics.

  3. Processes involved in the development of latent fingerprints using the cyanoacrylate fuming method.

    PubMed

    Lewis, L A; Smithwick, R W; Devault, G L; Bolinger, B; Lewis, S A

    2001-03-01

    Chemical processes involved in the development of latent fingerprints using the cyanoacrylate fuming method have been studied. Two major types of latent prints have been investigated-clean and oily prints. Scanning electron microscopy (SEM) has been used as a tool for determining the morphology of the polymer developed separately on clean and oily prints after cyanoacrylate fuming. A correlation between the chemical composition of an aged latent fingerprint, prior to development, and the quality of a developed fingerprint has been observed in the morphology. The moisture in the print prior to fuming has been found to be more important than the moisture in the air during fuming for the development of a useful latent print. In addition, the amount of time required to develop a high quality latent print has been found to be within 2 min. The cyanoacrylate polymerization process is extremely rapid. When heat is used to accelerate the fuming process, typically a period of 2 min is required to develop the print. The optimum development time depends upon the concentration of cyanoacrylate vapors within the enclosure.

  4. Inflammatory and genotoxic responses during 30-day welding-fume exposure period.

    PubMed

    Yu, Il Je; Song, Kyung Seuk; Maeng, Seung Hee; Kim, Soo Jin; Sung, Jae Hyuck; Han, Jeong Hee; Chung, Yong Hyun; Cho, Myung Haing; Chung, Kyu Hyuck; Han, Kuy Tae; Hyun, Jin Sook; Kim, Kwang Jong

    2004-12-01

    Welder's pneumoconiosis has generally been determined to be benign and unassociated with respiratory symptoms based on the absence of pulmonary-function abnormalities in welders with marked radiographic abnormalities. In previous studies, the current authors suggested a three-phase lung fibrosis process to study the pathological process of lung fibrosis and found that the critical point for recovery was after 30 days of welding-fume exposure at a high dose, at which point early and delicate fibrosis was observed in the perivascular and peribronchiolar regions. Accordingly, the current study investigated the inflammatory and genotoxic responses during a 30-day period of welding-fume exposure to elucidate the process of fibrosis. As such, rats were exposed to manual metal arc-stainless steel (MMA-SS) welding fumes at concentrations of 65.6 +/- 2.9 (low dose) and 116.8 +/- 3.9 mg/m3 (high dose) total suspended particulate for 2 h per day in an inhalation chamber for 30 days. Animals were sacrificed after the initial 2 h exposure, and after 15 and 30 days of exposure. The rats exposed to the welding fumes exhibited a statistically significant (P < 0.05) decrease in body weight when compared to the control during the 30-day exposure period, yet an elevated cellular differential count and higher levels of albumin, LDH, and beta-NAG, but not elevated TNF-alpha, and IL-1beta in the acellular bronchoalveolar lavage fluid. In addition, the DNA damage resulting from 30 days of welding-fume exposure was confirmed by a comet assay and the inmmunohistochemistry for 8-hydroxydeoxyguanine (8-OH-dG). Consequently, the elevated inflammatory and genotoxic indicators confirmed the lung injury and inflammation caused by the MMA-SS welding-fume exposure.

  5. Stabilization of heavy metals in MSWI fly ash using silica fume

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Xinying; Chen, Quanyuan; State Environmental Protection Engineering Center for Pollution Treatment and Control in Textile Industry, Donghua University, Shanghai 201620

    Highlights: • The stabilization of heavy metals in MSWI fly ash was investigated. • The addition of silica fume effectively reduced the leaching of Pb and Cd. • The relation of solid phase transformation and leaching behavior of heavy metals was discussed. - Abstract: The objective of this work was to investigate the feasibility and effectiveness of silica fume on stabilizing heavy metals in municipal solid waste incineration (MSWI) fly ash. In addition to compressive strength measurements, hydrated pastes were characterized by X-ray diffraction (XRD), thermal-analyses (DTA/TG), and MAS NMR ({sup 27}Al and {sup 29}Si) techniques. It was found thatmore » silica fume additions could effectively reduce the leaching of toxic heavy metals. At the addition of 20% silica fume, leaching concentrations for Cu, Pb and Zn of the hydrated paste cured for 7 days decreased from 0.32 mg/L to 0.05 mg/L, 40.99 mg/L to 4.40 mg/L, and 6.96 mg/L to 0.21 mg/L compared with the MSWI fly ash. After curing for 135 days, Cd and Pb in the leachates were not detected, while Cu and Zn concentrations decreased to 0.02 mg/L and 0.03 mg/L. The speciation of Pb and Cd by the modified version of the European Community Bureau of Reference (BCR) extractions showed that these metals converted into more stable state in hydrated pastes of MSWI fly ash in the presence of silica fume. Although exchangeable and weak-acid soluble fractions of Cu and Zn increased with hydration time, silica fume addition of 10% can satisfy the requirement of detoxification for heavy metals investigated in terms of the identification standard of hazardous waste of China.« less

  6. Fate of manganese associated with the inhalation of welding fumes: potential neurological effects.

    PubMed

    Antonini, James M; Santamaria, Annette B; Jenkins, Neil T; Albini, Elisa; Lucchini, Roberto

    2006-05-01

    Welding fumes are a complex mixture composed of different metals. Most welding fumes contain a small percentage of manganese. There is an emerging concern among occupational health officials about the potential neurological effects associated with the exposure to manganese in welding fumes. Little is known about the fate of manganese that is complexed with other metals in the welding particles after inhalation. Depending on the welding process and the composition of the welding electrode, manganese may be present in different oxidation states and have different solubility properties. These differences may affect the biological responses to manganese after the inhalation of welding fumes. Manganese intoxication and the associated neurological symptoms have been reported in individual cases of welders who have been exposed to high concentrations of manganese-containing welding fumes due to work in poorly ventilated areas. However, the question remains as to whether welders who are exposed to low levels of welding fumes over long periods of time are at risk for the development of neurological diseases. For the most part, questions remain unanswered. There is still paucity of adequate scientific reports on welders who suffered significant neurotoxicity, hence there is a need for well-designed epidemiology studies that combine complete information on the occupational exposure of welders with both behavioral and biochemical endpoints of neurotoxicity.

  7. Profiling mild steel welding processes to reduce fume emissions and costs in the workplace.

    PubMed

    Keane, Michael J; Siert, Arlen; Chen, Bean T; Stone, Samuel G

    2014-05-01

    To provide quantitative information to choose the best welding processes for minimizing workplace emissions, nine gas metal arc welding (GMAW) processes for mild steel were assessed for fume generation rates, normalized fume generation rates (milligram fume per gram of electrode consumed), and normalized generation rates for elemental manganese, nickel, and iron. Shielded metal arc welding (SMAW) and flux-cored arc-welding (FCAW) processes were also profiled. The fumes were collected quantitatively in an American Welding Society-type fume chamber and weighed, recovered, homogenized, and analyzed by inductively coupled atomic emission spectroscopy for total metals. The processes included GMAW with short circuit, globular transfer, axial spray, pulsed spray, Surface Tension Transfer™, Regulated Metal Deposition™, and Cold Metal Transfer™ (CMT) modes. Flux-cored welding was gas shielded, and SMAW was a single rod type. Results indicate a wide range of fume emission factors for the process variations studied. Fume emission rates per gram of electrode consumed were highest for SMAW (~13 mg fume g(-1) electrode) and lowest for GMAW processes such as pulsed spray (~1.5mg g(-1)) and CMT (~1mg g(-1)). Manganese emission rates per gram of electrode consumed ranged from 0.45 mg g(-1) (SMAW) to 0.08 mg g(-1) (CMT). Nickel emission rates were generally low and ranged from ~0.09 (GMAW short circuit) to 0.004 mg g(-1) (CMT). Iron emission rates ranged from 3.7 (spray-mode GMAW) to 0.49 mg g(-1) (CMT). The processes studied have significantly different costs, and cost factors are presented based on a case study to allow comparisons between processes in specific cost categories. Costs per linear meter of weld were $31.07 (SMAW), $12.37 (GMAW short circuit), and $10.89 (FCAW). Although no single process is the best for minimizing fume emissions and costs while satisfying the weld requirements, there are several processes that can minimize emissions. This study provides

  8. Profiling Mild Steel Welding Processes to Reduce Fume Emissions and Costs in the Workplace

    PubMed Central

    Keane, Michael J.; Siert, Arlen; Chen, Bean T.; Stone, Samuel G.

    2015-01-01

    To provide quantitative information to choose the best welding processes for minimizing workplace emissions, nine gas metal arc welding (GMAW) processes for mild steel were assessed for fume generation rates, normalized fume generation rates (milligram fume per gram of electrode consumed), and normalized generation rates for elemental manganese, nickel, and iron. Shielded metal arc welding (SMAW) and flux-cored arc-welding (FCAW) processes were also profiled. The fumes were collected quantitatively in an American Welding Society-type fume chamber and weighed, recovered, homogenized, and analyzed by inductively coupled atomic emission spectroscopy for total metals. The processes included GMAW with short circuit, globular transfer, axial spray, pulsed spray, Surface Tension Transfer™, Regulated Metal Deposition™, and Cold Metal Transfer™ (CMT) modes. Flux-cored welding was gas shielded, and SMAW was a single rod type. Results indicate a wide range of fume emission factors for the process variations studied. Fume emission rates per gram of electrode consumed were highest for SMAW (~13 mg fume g−1 electrode) and lowest for GMAW processes such as pulsed spray (~1.5 mg g−1) and CMT (~1 mg g−1). Manganese emission rates per gram of electrode consumed ranged from 0.45 mg g−1 (SMAW) to 0.08 mg g−1 (CMT). Nickel emission rates were generally low and ranged from ~0.09 (GMAW short circuit) to 0.004 mg g−1 (CMT). Iron emission rates ranged from 3.7 (spray-mode GMAW) to 0.49 mg g−1 (CMT). The processes studied have significantly different costs, and cost factors are presented based on a case study to allow comparisons between processes in specific cost categories. Costs per linear meter of weld were $31.07 (SMAW), $12.37 (GMAW short circuit), and $10.89 (FCAW). Although no single process is the best for minimizing fume emissions and costs while satisfying the weld requirements, there are several processes that can minimize emissions. This study provides

  9. Red tree voles in the Columbia River Gorge and Hood River basin, Oregon

    Treesearch

    Eric D. Forsman; James K. Swingle; Michael A. McDonald; Scott A. Graham; Nicholas R. Hatch

    2009-01-01

    In 2003 to 2008, we conducted surveys to document the eastern and northern range limits of red tree voles (Arborimus longicaudus) in the Columbia River Gorge and Hood River basin, Oregon. Our survey indicated the current range of the vole includes the area from Wahkeena Creek, 20 km east of Troutdale to Seneca Fouts State Park, 6 km west of Hood...

  10. 9. LOOKING NORTH IN BOP SHOP ON SERVICE FLOOR OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. LOOKING NORTH IN BOP SHOP ON SERVICE FLOOR OF FURNACE AISLE AT FUME HOOD SHOWING COLLAR AND ENTRANCE FOR OXYGEN LANCES. - U.S. Steel Duquesne Works, Basic Oxygen Steelmaking Plant, Along Monongahela River, Duquesne, Allegheny County, PA

  11. 38. DETAIL OF COOLING WATER BOOSTER PUMP FOR OXYGEN FURNACES, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    38. DETAIL OF COOLING WATER BOOSTER PUMP FOR OXYGEN FURNACES, LANCES, AND FUME HOODS IN THE GAS WASHER PUMP HOUSE LOOKING EAST. - U.S. Steel Duquesne Works, Basic Oxygen Steelmaking Plant, Along Monongahela River, Duquesne, Allegheny County, PA

  12. Defense.gov Special Report: Fort Hood Shooting

    Science.gov Websites

    in the assailant's background, medical or military profile that might have provided an early warning Shootings President Barack Obama commended the military personnel, first responders and medical staff who interactive planar photo of Fort Hood, highlighting six buildings: 61st First Medical Brigade Annex

  13. Synthetic Reference Materials Based on Polymer Films for the Control of Welding Fumes Composition

    NASA Astrophysics Data System (ADS)

    Kuznetsova, O. V.; Kuznetsova, A. N.; Begunova, L. A.

    2017-04-01

    Analysis of the current hygienic situation in the welding production showed that the intensification of welding processes involves the deterioration of air quality, which negatively affects the welders health. Welders are exposed to a variety of metal fumes, including manganese that may elevate the risk for neurological diseases. The control of metals concentration in the air of the working area is difficult due to the lack of reference materials. The creation of reference materials of welding fumes composition is a challenge due to chemical characteristics of their physical properties. Synthetic samples in a form of the polymer film containing powder particles of welding fumes were create. Studies on the selection of the polymer were done. Experiments proved that the qualitative materials of synthetic welding fumes are obtained by using polyvinyl alcohol. The metals concentration in the samples was determined by X-ray fluorescence analysis. The obtained data demonstrates indirectly the uniform distribution of welding fumes powder particles on the polymer film.

  14. Selecting Processes to Minimize Hexavalent Chromium from Stainless Steel Welding: Eight welding processes/shielding gas combinations were assessed for generation of hexavalent chromium in stainless steel welding fumes.

    PubMed

    Keane, M; Siert, A; Stone, S; Chen, B; Slaven, J; Cumpston, A; Antonini, J

    2012-09-01

    Eight welding processes/shielding gas combinations were assessed for generation of hexavalent chromium (Cr 6+ ) in stainless steel welding fumes. The processes examined were gas metal arc welding (GMAW) (axial spray, short circuit, and pulsed spray modes), flux cored arc welding (FCAW), and shielded metal arc welding (SMAW). The Cr 6+ fractions were measured in the fumes; fume generation rates, Cr 6+ generation rates, and Cr 6+ generation rates per unit mass of welding wire were determined. A limited controlled comparison study was done in a welding shop including SMAW, FCAW, and three GMAW methods. The processes studied were compared for costs, including relative labor costs. Results indicate the Cr 6+ in the fume varied widely, from a low of 2800 to a high of 34,000 ppm. Generation rates of Cr 6+ ranged from 69 to 7800 μg/min, and Cr 6+ generation rates per unit of wire ranged from 1 to 270 μg/g. The results of field study were similar to the findings in the laboratory. The Cr 6+ (ppm) in the fume did not necessarily correlate with the Cr 6+ generation rate. Physical properties were similar for the processes, with mass median aerodynamic diameters ranging from 250 to 336 nm, while the FCAW and SMAW fumes were larger (360 and 670 nm, respectively). The pulsed axial spray method was the best choice of the processes studied based on minimal fume generation, minimal Cr 6+ generation, and cost per weld. This method is usable in any position, has a high metal deposition rate, and is relatively simple to learn and use.

  15. Entry and Elimination of Marine Mammal Brucella spp. by Hooded Seal (Cystophora cristata) Alveolar Macrophages In Vitro

    PubMed Central

    Larsen, Anett K.; Nymo, Ingebjørg H.; Boysen, Preben; Tryland, Morten; Godfroid, Jacques

    2013-01-01

    A high prevalence of Brucella pinnipedialis serology and bacteriology positive animals has been found in the Northeast Atlantic stock of hooded seal ( Cystophora cristata ); however no associated gross pathological changes have been identified. Marine mammal brucellae have previously displayed different infection patterns in human and murine macrophages. To investigate if marine mammal Brucella spp. are able to invade and multiply in cells originating from a presumed host species, we infected alveolar macrophages from hooded seal with a B . pinnipedialis hooded seal isolate. Hooded seal alveolar macrophages were also challenged with B . pinnipedialis reference strain (NCTC 12890) from harbor seal ( Phoca vitulina ), B . ceti reference strain (NCTC 12891) from harbor porpoise ( Phocoena phocoena ) and a B . ceti Atlantic white-sided dolphin ( Lagenorhynchus acutus ) isolate (M83/07/1), to evaluate possible species-specific differences. Brucella suis 1330 was included as a positive control. Alveolar macrophages were obtained by post mortem bronchoalveolar lavage of euthanized hooded seals. Phenotyping of cells in the lavage fluid was executed by flow cytometry using the surface markers CD14 and CD18. Cultured lavage cells were identified as alveolar macrophages based on morphology, expression of surface markers and phagocytic ability. Alveolar macrophages were challenged with Brucella spp. in a gentamicin protection assay. Following infection, cell lysates from different time points were plated and evaluated quantitatively for colony forming units. Intracellular presence of B . pinnipedialis hooded seal isolate was verified by immunocytochemistry. Our results show that the marine mammal brucellae were able to enter hooded seal alveolar macrophages; however, they did not multiply intracellularly and were eliminated within 48 hours, to the contrary of B. suis that showed the classical pattern of a pathogenic strain. In conclusion, none of the four marine mammal strains

  16. Alterations in welding process voltage affect the generation of ultrafine particles, fume composition, and pulmonary toxicity.

    PubMed

    Antonini, James M; Keane, Michael; Chen, Bean T; Stone, Samuel; Roberts, Jenny R; Schwegler-Berry, Diane; Andrews, Ronnee N; Frazer, David G; Sriram, Krishnan

    2011-12-01

    The goal was to determine if increasing welding voltage changes the physico-chemical properties of the fume and influences lung responses. Rats inhaled 40 mg/m³ (3 h/day × 3 days) of stainless steel (SS) welding fume generated at a standard voltage setting of 25 V (regular SS) or at a higher voltage (high voltage SS) of 30 V. Particle morphology, size and composition were characterized. Bronchoalveolar lavage was performed at different times after exposures to assess lung injury. Fumes collected from either of the welding conditions appeared as chain-like agglomerates of nanometer-sized primary particles. High voltage SS welding produced a greater number of ultrafine-sized particles. Fume generated by high voltage SS welding was higher in manganese. Pulmonary toxicity was more substantial and persisted longer after exposure to the regular SS fume. In summary, a modest raise in welding voltage affected fume size and elemental composition and altered the temporal lung toxicity profile.

  17. Chemical characteristics and leachability of organically contaminated heavy metal sludge solidified by silica fume and cement.

    PubMed

    Jun, K S; Hwang, B G; Shin, H S; Won, Y S

    2001-01-01

    This paper discusses the development of mixtures with silica fume as a stabilization/solidification agent and binder for industrial wastewater residue containing organic and heavy metal contaminants. The UCS (Unconfined Compressive Strength) gradually increased to 66.7% as the silica fume content increased to 15%. The leaching of TOC and chromium decreased as more OPC was substituted with silica fume. When the mix had 5% silica fume, it retained about 85% TOC, and chromium leached out 0.76 mg-Cr/g-Cr in acidic solution. Also, microstructural studies on the solidified wastes through the scanning electron microscopy/energy dispersive spectroscopy (SEM/EDS) and X-ray diffraction analysis showed that the silica fume caused an inhibition to the ettringite formation which did not contribute to setting, but coated the cement particles and retarded the setting reactions. The results indicated that the incorporation of silica fume into the cement matrix minimized the detrimental effects of organic materials on the cement hydration reaction and contaminant leachability.

  18. The humoral immune response of mice exposed to manual metal arc stainless steel-welding fumes.

    PubMed

    Anderson, Stacey E; Meade, B Jean; Butterworth, Leon F; Munson, Albert E

    2007-01-01

    Arc welding is one of the most common forms of welding and includes the use of stainless steel electrodes that emit fumes containing chromium and nickel. Epidemological studies suggest a correlation between arc welding and adverse respiratory health effects. Studies evaluating the immunotoxic effects of welding fumes are limited due to the large number of variables associated with welding. This work investigates the immunotoxic effects of welding fumes by analyzing the in vivo and in vitro IgM response to a T-dependent antigen after welding fume exposure. Significant decreases in the total IgM activity/10(6) viable cells and total IgM activity/well were observed in splenocytes exposed to 5 mu g/ml of either total or soluble welding fumes. A significant reduction in the specific IgM activity in lung associated lymph node cells was also observed following four pharyngeal aspirations of 10 mg/kg total or soluble welding fumes to mice. Significant elevations in the absolute lymph node cell numbers for both B- and T-cells including the CD4(+) and CD8(+) subsets were observed. These results demonstrate that exposure to manual metal-stainless steel welding fumes is immunosuppressive in the presence of increased lymphoctye numbers in mice and raises concerns regarding the potential for adverse immunological effects to impact respiratory health in humans.

  19. Histological Study of the Toxic Effects of Solder Fumes on Spermatogenesis in Rats

    PubMed Central

    Arab, Mohammad Reza; Heidari, Mohammad Hossein; Mashhadi, Rezvaneh; Mirzaei, Ramazan; Jahantigh, Mehdi

    2011-01-01

    Objective: Toxic fumes generated during the soldering process contain various contaminants released at sufficient rates to cause both short- and long-term health problems. Studies have shown that these fumes change the quality and quantity of semen fluid in exposed workers. The aim of the present study was to determine the potentially toxic effects of solder fumes on spermatogenesis in seminiferous tubules of rats as an experimental model, with conditioned media in an exposed chamber. Materials and Methods: A total number of 48 male Sprague Dawley adult rats were randomly divided into experimental (n=30) and control (n=18) groups. Based on exposure time, each group was further subdivided into two, four and six subgroups. Rats in the experimental groups were exposed to solder fumes in an exposure chamber for one hour/ day. The concentrations of fumes [formaldehyde, stanum (Sn) and lead (Pb)] were measured by a standard method via atomic absorption and spectrophotometry. According to a timetable, under deep anesthesia, the rats of both experimental and control subgroups were killed. After fixation of testes, specimens were weighed and routinely processed. Paraffin sections were stained by hematoxylin and eosin. Spermiogenesis index was calculated and data analyzed by Mann Whitney NPAR test. Results: Analysis of air samples in the exposure chamber showed the following fume concentrations: 0.193 mg/m3 for formaldehyde, 0.35 mg/m3 for Sn and 3 mg/m3 for Pb. Although there was no significant difference in testes weight between control and experimental subgroups, there was only a significant difference in spermiogenesis index between the six week experimental and control subgroups (p<0.02). Conclusion: The results of this study showed that solder fumes can change the spermiogenesis index in experimental groups in a time dependent manner. PMID:23671821

  20. 42 CFR 84.135 - Half-mask facepieces, full facepieces, hoods, and helmets; fit; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Half-mask facepieces, full facepieces, hoods, and... OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.135 Half-mask facepieces, full facepieces, hoods, and helmets; fit; minimum requirements. (a) Half-mask facepieces and full facepieces shall...

  1. Application of a prospective model for calculating worker exposure due to the air pathway for operations in a laboratory.

    PubMed

    Grimbergen, T W M; Wiegman, M M

    2007-01-01

    In order to arrive at recommendations for guidelines on maximum allowable quantities of radioactive material in laboratories, a proposed mathematical model was used for the calculation of transfer fractions for the air pathway. A set of incident scenarios was defined, including spilling, leakage and failure of the fume hood. For these 'common incidents', dose constraints of 1 mSv and 0.1 mSv are proposed in case the operations are being performed in a controlled area and supervised area, respectively. In addition, a dose constraint of 1 microSv is proposed for each operation under regular working conditions. Combining these dose constraints and the transfer fractions calculated with the proposed model, maximum allowable quantities were calculated for different laboratory operations and situations. Provided that the calculated transfer fractions can be experimentally validated and the dose constraints are acceptable, it can be concluded from the results that the dose constraint for incidents is the most restrictive one. For non-volatile materials this approach leads to quantities much larger than commonly accepted. In those cases, the results of the calculations in this study suggest that limitation of the quantity of radioactive material, which can be handled safely, should be based on other considerations than the inhalation risks. Examples of such considerations might be the level of external exposure, uncontrolled spread of radioactive material by surface contamination, emissions in the environment and severe accidents like fire.

  2. Effects of acoustic hood on noise, CFC-11, and particulate matter in a recycling system for waste refrigerator cabinet.

    PubMed

    Guo, Jie; Fang, Wenxiong; Yang, Yichen; Xu, Zhenming

    2014-11-01

    The mechanical-physical process was proven to be technologically feasible for waste refrigerator recycling and has been widely used in the typical e-waste recycling factories in China. In this study, effects of the acoustic hood on the reduction of noise level, CFC-11, and heavy metals (Cr, Ni, Cu, Cd, and Pb) in particulate matter (PM) were evaluated. For noise pollution, the noise level inside and outside the acoustic hood was 96.4 and 78.9 dB, respectively. Meanwhile, it had a significant effect on A-weighted sound level with a reduction from 98.3 to 63.6 dB. For CFC-11 exposure, abundant CFC-11 (255 mg/m(3)) was detected in the acoustic hood. However, the mean concentration of CFC-11 at the outline of polyurethane foam collection was obviously diminished to 14 mg/m(3), and no CFC-11 was monitored around the acoustic hood. The concentrations of PM and heavy metals in PM outside the acoustic hood were lower than those inside the acoustic hood due to the physical barriers of the acoustic hood. Based on the risk assessment, only adverse health effect caused by Pb might likely appear. All the results can provide the basic data for pollution control and risk assessment in waste refrigerator recycling system.

  3. Reduction of Biomechanical and Welding Fume Exposures in Stud Welding.

    PubMed

    Fethke, Nathan B; Peters, Thomas M; Leonard, Stephanie; Metwali, Mahmoud; Mudunkotuwa, Imali A

    2016-04-01

    The welding of shear stud connectors to structural steel in construction requires a prolonged stooped posture that exposes ironworkers to biomechanical and welding fume hazards. In this study, biomechanical and welding fume exposures during stud welding using conventional methods were compared to exposures associated with use of a prototype system that allowed participants to weld from an upright position. The effect of base material (i.e. bare structural beam versus galvanized decking) on welding fume concentration (particle number and mass), particle size distribution, and particle composition was also explored. Thirty participants completed a series of stud welding simulations in a local apprenticeship training facility. Use of the upright system was associated with substantial reductions in trunk inclination and the activity levels of several muscle groups. Inhalable mass concentrations of welding fume (averaged over ~18 min) when using conventional methods were high (18.2 mg m(-3) for bare beam; 65.7 mg m(-3) for through deck), with estimated mass concentrations of iron (7.8 mg m(-3) for bare beam; 15.8 mg m(-3) for through deck), zinc (0.2 mg m(-3) for bare beam; 15.8 mg m(-3) for through deck), and manganese (0.9 mg m(-3) for bare beam; 1.5 mg m(-3) for through deck) often exceeding the American Conference of Governmental Industrial Hygienists Threshold Limit Values (TLVs). Number and mass concentrations were substantially reduced when using the upright system, although the total inhalable mass concentration remained above the TLV when welding through decking. The average diameters of the welding fume particles for both bare beam (31±17 nm) through deck conditions (34±34 nm) and the chemical composition of the particles indicated the presence of metallic nanoparticles. Stud welding exposes ironworkers to potentially high levels of biomechanical loading (primarily to the low back) and welding fume. The upright system used in this study improved exposure

  4. Optimum Tilt Angle of Flow Guide in Steam Turbine Exhaust Hood Considering the Effect of Last Stage Flow Field

    NASA Astrophysics Data System (ADS)

    CAO, Lihua; LIN, Aqiang; LI, Yong; XIAO, Bin

    2017-07-01

    Heat transfer and vacuum in condenser are influenced by the aerodynamic performance of steam turbine exhaust hood. The current research on exhaust hood is mainly focused on analyzing flow loss and optimal design of its structure without consideration of the wet steam condensing flow and the exhaust hood coupled with the front and rear parts. To better understand the aerodynamic performance influenced by the tilt angle of flow guide inside a diffuser, taking a 600 MW steam turbine as an example, a numerical simulator CFX is adopted to solve compressible three-dimensional (3D) Reynolds time-averaged N-S equations and standard k- ɛ turbulence model. And the exhaust hood flow field influenced by different tilt angles of flow guide is investigated with consideration of the wet steam condensing flow and the exhaust hood coupled with the last stage blades and the condenser throat. The result shows that the total pressure loss coefficient and the static pressure recovery coefficient of exhaust hood change regularly and monotonously with the gradual increase of tilt angle of flow guide. When the tilt angle of flow guide is within the range of 30° to 40°, the static pressure recovery coefficient is in the range of 15.27% to 17.03% and the total pressure loss coefficient drops to approximately 51%, the aerodynamic performance of exhaust hood is significantly improved. And the effective enthalpy drop in steam turbine increases by 0.228% to 0.274%. It is feasible to obtain a reasonable title angle of flow guide by the method of coupling the last stage and the condenser throat to exhaust hood in combination of the wet steam model, which provides a practical guidance to flow guide transformation and optimal design in exhaust hood.

  5. Effect of gasoline fumes on reproductive function in male albino rats.

    PubMed

    Owagboriaye, Folarin O; Dedeke, Gabriel A; Ashidi, Joseph S; Aladesida, Adeyinka A; Olooto, Wasiu E

    2018-02-01

    The increase in the frequency of exposure to gasoline fumes and the growing incidence of infertility among humans has been a major concern and subject of discussion over the years in Nigeria. We therefore present the reproductive effect of gasoline fumes on inhalation exposure in 40 male albino rats. The rats were randomized into five experimental treatments (T) with eight rats per treatment. T1 (control) was exposed to distilled water while T2, T3, T4, and T5 were exposed to gasoline fumes in exposure chambers for 1, 3, 5, and 9 h daily respectively for 12 weeks. Serum level of testosterone, follicle stimulating hormone (FSH), luteinizing hormone (LH), prolactin, oxidative stress markers in the testicular tissue, epididymal sperm health assessment, and testicular histopathology of the rats were used as a diagnostic marker of reproductive dysfunction. Significant (p < 0.05) alterations in the levels of all the reproductive hormones and oxidative stress markers assayed were observed in rats exposed to gasoline fume. Significant reductions (p < 0.05) in sperm count and percentage motility in the exposed rats were observed. Significant (p < 0.05) increased in abnormal sperm cells characterized by damaged head, bent tail, damaged tail, and without head were also observed in the exposed rats. Histopathologically, severe degenerative testicular architectural lesions characterized by alterations in all the generations of sperm cells and reduction of interstitial cells were seen in the exposed rats. Gasoline fume is thus said to interfere with spermatogenesis and impair fertility in male gonad.

  6. Transport and Deposition of Welding Fume Agglomerates in a Realistic Human Nasal Airway.

    PubMed

    Tian, Lin; Inthavong, Kiao; Lidén, Göran; Shang, Yidan; Tu, Jiyuan

    2016-07-01

    Welding fume is a complex mixture containing ultra-fine particles in the nanometer range. Rather than being in the form of a singular sphere, due to the high particle concentration, welding fume particles agglomerate into long straight chains, branches, or other forms of compact shapes. Understanding the transport and deposition of these nano-agglomerates in human respiratory systems is of great interest as welding fumes are a known health hazard. The neurotoxin manganese (Mn) is a common element in welding fumes. Particulate Mn, either as soluble salts or oxides, that has deposited on the olfactory mucosa in human nasal airway is transported along the olfactory nerve to the olfactory bulb within the brain. If this Mn is further transported to the basal ganglia of the brain, it could accumulate at the part of the brain that is the focal point of its neurotoxicity. Accounting for various dynamic shape factors due to particle agglomeration, the current computational study is focused on the exposure route, the deposition pattern, and the deposition efficiency of the inhaled welding fume particles in a realistic human nasal cavity. Particular attention is given to the deposition pattern and deposition efficiency of inhaled welding fume agglomerates in the nasal olfactory region. For particles in the nanoscale, molecular diffusion is the dominant transport mechanism. Therefore, Brownian diffusion, hydrodynamic drag, Saffman lift force, and gravitational force are included in the model study. The deposition efficiencies for single spherical particles, two kinds of agglomerates of primary particles, two-dimensional planar and straight chains, are investigated for a range of primary particle sizes and a range of number of primary particles per agglomerate. A small fraction of the inhaled welding fume agglomerates is deposited on the olfactory mucosa, approximately in the range 0.1-1%, and depends on particle size and morphology. The strong size dependence of the deposition

  7. Brucella pinnipedialis hooded seal (Cystophora cristata) strain in the mouse model with concurrent exposure to PCB 153.

    PubMed

    Nymo, Ingebjørg H; das Neves, Carlos G; Tryland, Morten; Bårdsen, Bård-Jørgen; Santos, Renato Lima; Turchetti, Andreia Pereira; Janczak, Andrew M; Djønne, Berit; Lie, Elisabeth; Berg, Vidar; Godfroid, Jacques

    2014-05-01

    Brucellosis, a worldwide zoonosis, is linked to reproductive problems in primary hosts. A high proportion of Brucella-positive hooded seals (Cystophora cristata) have been detected in the declined Northeast Atlantic stock. High concentrations of polychlorinated biphenyls (PCBs) have also been discovered in top predators in the Arctic, including the hooded seal, PCB 153 being most abundant. The aim of this study was to assess the pathogenicity of Brucella pinnipedialis hooded seal strain in the mouse model and to evaluate the outcome of Brucella spp. infection after exposure of mice to PCB 153. BALB/c mice were infected with B. pinnipedialis hooded seal strain or Brucella suis 1330, and half from each group was exposed to PCB 153 through the diet. B. pinnipedialis showed a reduced pathogenicity in the mouse model as compared to B. suis 1330. Exposure to PCB 153 affected neither the immunological parameters, nor the outcome of the infection. Altogether this indicates that it is unlikely that B. pinnipedialis contribute to the decline of hooded seals in the Northeast Atlantic. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Exposure to Inhalable, Respirable, and Ultrafine Particles in Welding Fume

    PubMed Central

    Pesch, Beate

    2012-01-01

    This investigation aims to explore determinants of exposure to particle size-specific welding fume. Area sampling of ultrafine particles (UFP) was performed at 33 worksites in parallel with the collection of respirable particles. Personal sampling of respirable and inhalable particles was carried out in the breathing zone of 241 welders. Median mass concentrations were 2.48 mg m−3 for inhalable and 1.29 mg m−3 for respirable particles when excluding 26 users of powered air-purifying respirators (PAPRs). Mass concentrations were highest when flux-cored arc welding (FCAW) with gas was applied (median of inhalable particles: 11.6 mg m−3). Measurements of particles were frequently below the limit of detection (LOD), especially inside PAPRs or during tungsten inert gas welding (TIG). However, TIG generated a high number of small particles, including UFP. We imputed measurements fume. Concentrations were mainly predicted by the welding process and were significantly higher when local exhaust ventilation (LEV) was inefficient or when welding was performed in confined spaces. Substitution of high-emission techniques like FCAW, efficient LEV, and using PAPRs where applicable can reduce exposure to welding fume. However, harmonizing the different exposure metrics for UFP (as particle counts) and for the respirable or inhalable fraction of the welding fume (expressed as their mass) remains challenging. PMID:22539559

  9. Exposure to inhalable, respirable, and ultrafine particles in welding fume.

    PubMed

    Lehnert, Martin; Pesch, Beate; Lotz, Anne; Pelzer, Johannes; Kendzia, Benjamin; Gawrych, Katarzyna; Heinze, Evelyn; Van Gelder, Rainer; Punkenburg, Ewald; Weiss, Tobias; Mattenklott, Markus; Hahn, Jens-Uwe; Möhlmann, Carsten; Berges, Markus; Hartwig, Andrea; Brüning, Thomas

    2012-07-01

    This investigation aims to explore determinants of exposure to particle size-specific welding fume. Area sampling of ultrafine particles (UFP) was performed at 33 worksites in parallel with the collection of respirable particles. Personal sampling of respirable and inhalable particles was carried out in the breathing zone of 241 welders. Median mass concentrations were 2.48 mg m(-3) for inhalable and 1.29 mg m(-3) for respirable particles when excluding 26 users of powered air-purifying respirators (PAPRs). Mass concentrations were highest when flux-cored arc welding (FCAW) with gas was applied (median of inhalable particles: 11.6 mg m(-3)). Measurements of particles were frequently below the limit of detection (LOD), especially inside PAPRs or during tungsten inert gas welding (TIG). However, TIG generated a high number of small particles, including UFP. We imputed measurements fume. Concentrations were mainly predicted by the welding process and were significantly higher when local exhaust ventilation (LEV) was inefficient or when welding was performed in confined spaces. Substitution of high-emission techniques like FCAW, efficient LEV, and using PAPRs where applicable can reduce exposure to welding fume. However, harmonizing the different exposure metrics for UFP (as particle counts) and for the respirable or inhalable fraction of the welding fume (expressed as their mass) remains challenging.

  10. A male hooded merganser swims in the waters of KSC

    NASA Technical Reports Server (NTRS)

    1999-01-01

    The distinctive fan-shaped, black-bordered crest and striped breast identify this hooded merganser, swimming in the waters of the Merritt Island National Wildlife Refuge at Kennedy Space Center. Usually found from Alaska and Canada south to Nebraska, Oregon and Tennessee, hooded mergansers winter south to Mexico and the Gulf Coast, including KSC. The open water of the refuge provides wintering areas for 23 species of migratory waterfowl, as well as a year-round home for great blue herons, great egrets, wood storks, cormorants, brown pelicans and other species of marsh and shore birds. The 92,000-acre refuge is also habitat for more than 310 species of birds, 25 mammals, 117 fishes and 65 amphibians and reptiles.

  11. Locating inputs of freshwater to Lynch Cove, Hood Canal, Washington, using aerial infrared photography

    USGS Publications Warehouse

    Sheibley, Rich W.; Josberger, Edward G.; Chickadel, Chris

    2010-01-01

    The input of freshwater and associated nutrients into Lynch Cove and lower Hood Canal (fig. 1) from sources such as groundwater seeps, small streams, and ephemeral creeks may play a major role in the nutrient loading and hydrodynamics of this low dissolved-oxygen (hypoxic) system. These disbursed sources exhibit a high degree of spatial variability. However, few in-situ measurements of groundwater seepage rates and nutrient concentrations are available and thus may not represent adequately the large spatial variability of groundwater discharge in the area. As a result, our understanding of these processes and their effect on hypoxic conditions in Hood Canal is limited. To determine the spatial variability and relative intensity of these sources, the U.S. Geological Survey Washington Water Science Center collaborated with the University of Washington Applied Physics Laboratory to obtain thermal infrared (TIR) images of the nearshore and intertidal regions of Lynch Cove at or near low tide. In the summer, cool freshwater discharges from seeps and streams, flows across the exposed, sun-warmed beach, and out on the warm surface of the marine water. These temperature differences are readily apparent in aerial thermal infrared imagery that we acquired during the summers of 2008 and 2009. When combined with co-incident video camera images, these temperature differences allow identification of the location, the type, and the relative intensity of the sources.

  12. Fume Cupboards in Schools. (Revision of Design Note 29). Building Bulletin 88.

    ERIC Educational Resources Information Center

    Tawney, David

    Regulations require hazardous gases in school science classrooms to be controlled, i.e., their levels in the air kept below the exposure limits, with fume cupboards being the most usual method. This document reviews the requirements for fume cupboards used in schools and colleges for teaching the sciences, mainly chemistry and biology, up to…

  13. New approach to reducing water consumption in commercial kitchen hood

    NASA Astrophysics Data System (ADS)

    Asmuin, N.; Pairan, M. R.

    2017-09-01

    Water mist sprays are used in wide range of application. However it is depend to the spray characteristic to suit the particular application. The modern commercial kitchen hood ventilation system was adopted with the water mist nozzle technology as an additional tool to increase the filtration efficiency. However, low level of filtration effectiveness and high water consumption were the major problems among the Commercial Kitchen Ventilation expert. Therefore, this study aims to develop a new mist spray technology to replacing the conventional KSJB nozzle (KSJB is a nozzle’s name). At the same time, an appropriate recommended location to install the nozzle in kitchen hood system was suggested. An extensive simulation works were carried out to observe the spray characteristics, ANSYS (FLUENT) was used for simulation wise. In the case of nozzle studies, nozzles were tested at 1 bar pressure of water and air. In comparison with conventional nozzles configuration, this new approach suggested nozzle configuration was reduce up to 50% of water consumption, which by adopted 3 numbers of nozzles instead of 6 numbers of nozzles in the commercial kitchen hood system. Therefore, this nozzle will be used in industry for their benefits of water consumption, filtration efficiency and reduced the safety limitations.

  14. Crashworthiness studies of locomotive wide nose short hood designs

    DOT National Transportation Integrated Search

    1999-11-01

    This paper investigates the parameters that influence the structural response of typical wide nose locomotive short hoods involved in offset collisions. This accident scenario was chosen based upon the railway collision that occurred in Selma, North ...

  15. "Always the Outlaw": The Potential for Subversion of the Metanarrative in Retellings of Robin Hood

    ERIC Educational Resources Information Center

    Gates, Geoffrey

    2006-01-01

    This paper examines six recent retellings of Robin Hood and concentrates on the representation of class, religion and gender in the texts. The question is asked: "what values do the texts implicitly or explicitly arm?" The idea that Robin Hood retellings are systematic of a socially and politically conservative ideology is interrogated by…

  16. Investigation of concrete containing condensed silica fume.

    DOT National Transportation Integrated Search

    1986-01-01

    The properties of hydraulic cement concretes containing silica fume were investigated to assess their suitability for use in overlays with s minimum thickness of 1 1/4 in. The properties studied were compressive and flexural strengths, bond strength,...

  17. Entrance and Survival of Brucella pinnipedialis Hooded Seal Strain in Human Macrophages and Epithelial Cells

    PubMed Central

    Briquemont, Benjamin; Sørensen, Karen K.; Godfroid, Jacques

    2013-01-01

    Marine mammal Brucella spp. have been isolated from pinnipeds (B. pinnipedialis) and cetaceans (B. ceti) from around the world. Although the zoonotic potential of marine mammal brucellae is largely unknown, reports of human disease exist. There are few studies of the mechanisms of bacterial intracellular invasion and multiplication involving the marine mammal Brucella spp. We examined the infective capacity of two genetically different B. pinnipedialis strains (reference strain; NTCT 12890 and a hooded seal isolate; B17) by measuring the ability of the bacteria to enter and replicate in cultured phagocytes and epithelial cells. Human macrophage-like cells (THP-1), two murine macrophage cell lines (RAW264.7 and J774A.1), and a human malignant epithelial cell line (HeLa S3) were challenged with bacteria in a gentamicin protection assay. Our results show that B. pinnipedialis is internalized, but is then gradually eliminated during the next 72 – 96 hours. Confocal microscopy revealed that intracellular B. pinnipedialis hooded seal strain colocalized with lysosomal compartments at 1.5 and 24 hours after infection. Intracellular presence of B. pinnipedialis hooded seal strain was verified by transmission electron microscopy. By using a cholesterol-scavenging lipid inhibitor, entrance of B. pinnipedialis hooded seal strain in human macrophages was significantly reduced by 65.8 % (± 17.3), suggesting involvement of lipid-rafts in intracellular entry. Murine macrophages invaded by B. pinnipedialis do not release nitric oxide (NO) and intracellular bacterial presence does not induce cell death. In summary, B. pinnipedialis hooded seal strain can enter human and murine macrophages, as well as human epithelial cells. Intracellular entry of B. pinnipedialis hooded seal strain involves, but seems not to be limited to, lipid-rafts in human macrophages. Brucella pinnipedialis does not multiply or survive for prolonged periods intracellulary. PMID:24376851

  18. DNA strand breakage and lipid peroxidation after exposure to welding fumes in vivo.

    PubMed

    Chuang, Cheng-Hung; Huang, Chong-En; Chen, Hsiu-Ling

    2010-01-01

    A remarkable number of complex aerosols are generated from welding processes. The objective of this study was to compare DNA damage and lipid peroxidation in plasma and in lung and in liver tissue of rats exposed to welding fumes in an exposure chamber with those of control animals. Three air samples from the chamber were also collected to assess the exposure dose for each exposure (total samplings = 18). Eight male Sprague-Dawley rats were exposed to welding fumes at a concentration of 1540.76 mg/m(3) for 10 min/day six times on day 1, day 3, day 7, day 15, day 30 and day 40. Lung, liver and kidney injury was measured following exposure, as well as in unexposed control rats (n = 4 at the beginning of the study). DNA strand breakage [tail moment (TMOM)] in exposed animals showed significant differences at day 1, day 4, day 7 and day 15 relative to the levels in control animals. Malondialdehyde (MDA, a lipid peroxidation product) levels increased gradually post-welding to 0.4 microM at 7 days. MDA and TMOM both reached maximum levels 7 days after the first exposure. At the start, an increasing trend in DNA strand breakage was more obvious than increases in MDA levels; MDA seemed to reflect long-term effects of exposure to welding fumes since it increased after 7 days and was sustained to 40 days in vivo. Significant differences in both MDA levels and DNA strand breakage were seen in lung, liver and kidney 40 days after the first fume inhalation. We conclude that acute exposure of rats to welding fumes causes noticeable oxidative damage and lipid peroxidation effects and that DNA damage may recover after long and repeat exposure. More chronic inhalation and low-dose studies are needed in order to further assess the effects of inhalation of welding fumes on DNA and to elucidate the possible causal mechanisms associated with the biologically damaging effects of welding fumes.

  19. [Effect of bitumen fume on neurotransmitter and ultrastructure in mice brain].

    PubMed

    Li, Hai-Ling; Guo, Xiang-Yun; Feng, San-Wei; Liu, Chang-Hai

    2006-12-01

    To observe the effects of bitumen fume on neurotransmitter and ultrastructure of mice brain and to investigate the toxicity of bitumen fume on nerve system of mice brain. The experimental mice were forced to inhale the bitumen fume at different exposure level and in different time periods. The contents of the three transmitters dopamine (DA), norepinephrine (NE), 5-hydroxytryptamine (5-HT) in mice brain were measured by the fluorescence meanwhile ultrastructure of mice brain was observed by electronic microscope. The ultrastructure of mice brain was observed under transmission electron microscopy. The contents of DA, NE and 5-HT in all groups decreased with the increasing of dose and prolonging of time (after 8 week, with the increasing of exposure lever, the content of DA, NE, 5-HT was respectively 2.194, 2.190, 2.181, 2.178 microg/g and 1.148, 1.138, 1.135 and 1.407, 1.403, 1.395 microg), but the results did not show significant differences. The structure of the mitochondria changes included the swollen mitochondria, chromatin margination, pyknosis and apoptosis in neuro cells and the processes of swollen astrocyte cells. The bitumen fume could induce changes of the ultrastructure of mice brain and affect the contents of neurotransmitter of mice brain.

  20. Changes of glycoconjugate expression in nasal respiratory mucosa of rats exposed to welding fumes.

    PubMed

    Jeong, Gil Nam; Jo, Un Bock; Yu, Il Je

    2007-09-01

    To investigate the effects of welding fumes on the glycoconjugates in nasal respiratory mucosa, male Sprague-Dawley rats were exposed to manual metal arc stainless steel (MMA-SS) welding fumes at a concentration of 56-76 mg/m(3) total suspended particulate for 2 h/day in an inhalation chamber for 90 days. During the exposure period, the experimental animals were sacrificed after 2 h and 15, 30, 60, and 90 days of exposure; then sections were examined using lectin histochemistry. Some remarkable changes, such as destroyed cilia, desquamation and mucification of epithelial cells, and destruction of nasal septal glands, were seen in the welding fume-exposed groups. Specific changes in the lectin binding patterns were also observed in the welding fume-exposed rats. The Ricinus communis agglutinin-I (RCA-I) staining of the cilia and columnar cells increased slightly when compared with the unexposed rats. The RCA-I and Ulex europaeus agglutinin-I (UEA-I) staining of the goblet cells also increased as the exposure continued. The mucigenous epithelial cells reacted with Bandeiraea simplicifolia lectin-I (BSL-I), RCA-I, and succinylated wheat germ agglutinin A (sWGA) after 15 days of exposure, which was not visible in the control group. The dorsal septal glands exhibited an affinity with peanut agglutinin (PNA), BSL-I, and RCA-I, which was also not visible in the control group. The affinity for Dolichos biflorus agglutinin (DBA), soybean agglutinin (SBA), PNA, sWGA, BSL-I, and UEA-I in the ventral septal glands of the welding fume-exposed groups tended to increase, whereas the concanavalin A (Con A) reactivity in the dorsal septal glands decreased slightly. In conclusion, it was assumed that the changes in the glycoconjugate residues in the nasal respiratory mucosa of the welding fume-exposed rats represented important components of defense mechanisms against the toxicants in the welding fumes.

  1. 42 CFR 84.175 - Half-mask facepieces, full facepieces, hoods, helmets, and mouthpieces; fit; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Half-mask facepieces, full facepieces, hoods....175 Half-mask facepieces, full facepieces, hoods, helmets, and mouthpieces; fit; minimum requirements. (a) Half-mask facepieces and full facepieces shall be designed and constructed to fit persons with...

  2. 14 CFR 93.61 - General rules: Lake Hood segment.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false General rules: Lake Hood segment. 93.61 Section 93.61 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... maneuvering for a safe landing requires further descent. ...

  3. A female hooded merganser swims in the waters of KSC

    NASA Technical Reports Server (NTRS)

    1999-01-01

    A female hooded merganser swims solo in the waters of the Merritt Island National Wildlife Refuge at Kennedy Space Center. The male is distinguished by a fan-shaped, black-bordered crest and striped breast. Usually found from Alaska and Canada south to Nebraska, Oregon and Tennessee, hooded mergansers winter south to Mexico and the Gulf Coast, including KSC. The open water of the refuge provides wintering areas for 23 species of migratory waterfowl, as well as a year-round home for great blue herons, great egrets, wood storks, cormorants, brown pelicans and other species of marsh and shore birds. The 92,000-acre refuge is also habitat for more than 310 species of birds, 25 mammals, 117 fishes and 65 amphibians and reptiles.

  4. Addition of Silica Fume to Improve Strength of Cement Paste

    NASA Astrophysics Data System (ADS)

    Chen, Jiajian; Chen, Hongniao; Li, Gu

    2018-03-01

    This study measured the packing densities of 0 to 30% silica fume (SF) added cementitious materials and strength of the cementitious pastes with various water content. The results revealed that addition of silica fume up to a certain level has great effects on packing density and strength. In-depth analysis illustrated that a lower W/CM ratio would not always result in a higher cube strength, and the range between 0.05 and 0.07 µm would be the amount of water film thickness (WFT) for muximum strength.

  5. Don Quixote, Machiavelli, and Robin Hood: public health practice, past and present.

    PubMed

    Mullan, F

    2000-05-01

    Since the mid-19th century, when the first formal health departments were established in the United States, commissioners, directors, and secretaries of public health have functioned as senior members of the staffs of public executives, mayors, governors, and presidents. They have provided important political, managerial, and scientific leadership to agencies of government that have played increasingly important roles in national life, from the sanitary revolution of the 19th century to the prevention of HIV/AIDS and the control of tobacco use today. Although public health officials come from a variety of backgrounds and oversee agencies of varied size and composition, there are philosophical themes that describe and define the commonality of their work. These themes are captured metaphorically by 3 celebrated figures: Don Quixote, Machiavelli, and Robin Hood. By turns, the public health official functions as a determined idealist (Don Quixote), a cunning political strategist (Machiavelli), and an agent who redistributes resources from the wealthier sectors of society to the less well off (Robin Hood.) All 3 personae are important, but, it is argued, Robin Hood is the most endangered.

  6. Home cage locomotor changes in non-human primates after prolonged welding-fume exposure.

    PubMed

    Kim, Choong Yong; Sung, Jae Hyuck; Chung, Yong Hyun; Park, Jung Duck; Han, Jeong Hee; Lee, Jong Seong; Heo, Jeong Doo; Yu, Il Je

    2013-12-01

    To define the relationship between the brain concentration of manganese and neurological signs, such as locomotion, after prolonged welding-fume exposure, cynomolgus monkeys were acclimated for 1 month and then divided into three concentration groups: unexposed, low concentration (31 mg/m(3) total suspended particulate (TSP), 0.9 mg/m(3) of Mn), and high concentration (62 mg/m(3) TSP, 1.95 mg/m(3) of Mn) of TSP. The monkeys were exposed to manual metal-arc stainless steel (MMA-SS) welding fumes for 2 h per day over 8 months in an inhalation chamber system equipped with an automatic fume generator. The home cage locomotor activity and patterns were determined using a camera system over 2-4 consecutive days. After 25 and 32 weeks of exposure, the home cage locomotor activity of the high-concentration primates was found to be 5-6 times higher than that of the unexposed primates, and this increased locomotor activity was maintained for 7 weeks after ceasing the welding-fume exposure, eventually subsiding to three times higher after 13 weeks of recovery. Therefore, the present results, along with our previous observations of a high magnetic resonance imaging (MRI) T1 signal in the globus pallidus and increased blood Mn concentration, indicate that prolonged welding-fume exposure can cause neurobehavioral changes in cynomolgus monkeys.

  7. Contrast fluoroscopic evaluation of gastrointestinal transit times with and without the use of falconry hoods in red-tailed hawks (Buteo jamaicensis).

    PubMed

    Doss, Grayson A; Williams, Jackie M; Mans, Christoph

    2017-11-01

    OBJECTIVE To evaluate gastrointestinal transit times in red-tailed hawks (Buteo jamaicensis) by use of contrast fluoroscopic imaging and investigate the effect of falconry hooding in these hawks on gastrointestinal transit time. DESIGN Prospective, randomized, blinded, complete crossover study. ANIMALS 9 healthy red-tailed hawks. PROCEDURES Hawks were gavage-fed a 30% weight-by-volume barium suspension (25 mL/kg [11.3 mL/lb]) into the crop. Fluoroscopic images were obtained at multiple time points after barium administration. Time to filling and emptying of various gastrointestinal tract organs and overall transit time were measured. The effect of hooding (hooded vs nonhooded) on these variables was assessed in a randomized complete crossover design. RESULTS In nonhooded birds, overall gastrointestinal transit time ranged from 30 to 180 minutes (mean ± SD, 100 ± 52 min). Time to complete crop emptying ranged from 30 to 180 minutes (83 ± 49 min). Contrast medium was present in the ventriculus in all birds within 5 minutes of administration and in the small intestines within 5 to 15 minutes (median, 5 min). Hooding of red-tailed hawks resulted in a significant delay of complete crop emptying (no hood, 83 ± 49 minutes; hood, 133 ± 48 minutes), but no significant effects of hooding were found on other measured variables. CONCLUSIONS AND CLINICAL RELEVANCE These results indicated that overall gastrointestinal transit times are faster in red-tailed hawks than has been reported for psittacines and that the use of a falconry hood in red-tailed hawks may result in delayed crop emptying. Hooding did not exert significant effects on overall gastrointestinal transit time in this raptorial species.

  8. 7. Process areas room. Incinerator and glove boxes (hoods) to ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. Process areas room. Incinerator and glove boxes (hoods) to the right. Filter boxes to the left. Looking south. - Plutonium Finishing Plant, Waste Incinerator Facility, 200 West Area, Richland, Benton County, WA

  9. Comparison of the behavior of stainless and mild steel manual metal arc welding fumes in rat lung.

    PubMed

    Kalliomäki, P L; Junttila, M L; Kalliomäki, K K; Lakomaa, E L; Kivelä, R

    1983-04-01

    The lung retention and clearance of manual metal arc (MMA) stainless steel and mild steel welding fumes were determined in the rat. The exposure simulated the actual welding situation. The duration of exposure in the "nose-only" exposure chamber was 1 h/workday for one, two, three, or four weeks in the retention study and for four weeks in the clearance study. The concentration of exogenous iron was determined by the magnetic measuring method. Instrumental neutron activation analysis was applied to determine the concentration of total iron, chromium, and nickel in the lungs. The results indicated that the lung retention and clearance patterns for the two types of welding fumes were different. A linear relationship was observed between the amount of stainless steel MMA welding fume retained in the lungs and the duration of exposure, whereas the retention of mild steel MMA welding fume in the lung was saturated as a function of the cumulative exposure time rates. The maximum amount of lung-retained contaminants was 880 micrograms for stainless steel MMA welding fume and 220 micrograms for mild steel MMA fume.

  10. Characterization of Tungsten Inert Gas (TIG) Welding Fume Generated by Apprentice Welders

    PubMed Central

    Graczyk, Halshka; Lewinski, Nastassja; Zhao, Jiayuan; Concha-Lozano, Nicolas; Riediker, Michael

    2016-01-01

    Tungsten inert gas welding (TIG) represents one of the most widely used metal joining processes in industry. Its propensity to generate a greater portion of welding fume particles at the nanoscale poses a potential occupational health hazard for workers. However, current literature lacks comprehensive characterization of TIG welding fume particles. Even less is known about welding fumes generated by welding apprentices with little experience in welding. We characterized TIG welding fume generated by apprentice welders (N = 20) in a ventilated exposure cabin. Exposure assessment was conducted for each apprentice welder at the breathing zone (BZ) inside of the welding helmet and at a near-field (NF) location, 60cm away from the welding task. We characterized particulate matter (PM4), particle number concentration and particle size, particle morphology, chemical composition, reactive oxygen species (ROS) production potential, and gaseous components. The mean particle number concentration at the BZ was 1.69E+06 particles cm−3, with a mean geometric mean diameter of 45nm. On average across all subjects, 92% of the particle counts at the BZ were below 100nm. We observed elevated concentrations of tungsten, which was most likely due to electrode consumption. Mean ROS production potential of TIG welding fumes at the BZ exceeded average concentrations previously found in traffic-polluted air. Furthermore, ROS production potential was significantly higher for apprentices that burned their metal during their welding task. We recommend that future exposure assessments take into consideration welding performance as a potential exposure modifier for apprentice welders or welders with minimal training. PMID:26464505

  11. Freshwater and Saline Loads of Dissolved Inorganic Nitrogen to Hood Canal and Lynch Cove, Western Washington

    USGS Publications Warehouse

    Paulson, Anthony J.; Konrad, Christopher P.; Frans, Lonna M.; Noble, Marlene; Kendall, Carol; Josberger, Edward G.; Huffman, Raegan L.; Olsen, Theresa D.

    2006-01-01

    Hood Canal is a long (110 kilometers), deep (175 meters) and narrow (2 to 4 kilometers wide) fjord of Puget Sound in western Washington. The stratification of a less dense, fresh upper layer of the water column causes the cold, saltier lower layer of the water column to be isolated from the atmosphere in the late summer and autumn, which limits reaeration of the lower layer. In the upper layer of Hood Canal, the production of organic matter that settles and consumes dissolved oxygen in the lower layer appears to be limited by the load of dissolved inorganic nitrogen (DIN): nitrate, nitrite, and ammonia. Freshwater and saline loads of DIN to Hood Canal were estimated from available historical data. The freshwater load of DIN to the upper layer of Hood Canal, which could be taken up by phytoplankton, came mostly from surface and ground water from subbasins, which accounts for 92 percent of total load of DIN to the upper layer of Hood Canal. Although DIN in rain falling on land surfaces amounts to about one-half of the DIN entering Hood Canal from subbasins, rain falling directly on the surface of marine waters contributed only 4 percent of the load to the upper layer. Point-source discharges and subsurface flow from shallow shoreline septic systems contributed less than 4 percent of the DIN load to the upper layer. DIN in saline water flowing over the sill into Hood Canal from Admiralty Inlet was at least 17 times the total load to the upper layer of Hood Canal. In September and October 2004, field data were collected to estimate DIN loads to Lynch Cove - the most inland marine waters of Hood Canal that routinely contain low dissolved-oxygen waters. Based on measured streamflow and DIN concentrations, surface discharge was estimated to have contributed about one-fourth of DIN loads to the upper layer of Lynch Cove. Ground-water flow from subbasins was estimated to have contributed about one-half of total DIN loads to the upper layer. In autumn 2004, the relative

  12. Relationship between welding fume concentration and systemic inflammation after controlled exposure of human subjects with welding fumes from metal inert gas brazing of zinc-coated materials.

    PubMed

    Brand, Peter; Bauer, Marcus; Gube, Monika; Lenz, Klaus; Reisgen, Uwe; Spiegel-Ciobanu, Vilia Elena; Kraus, Thomas

    2014-01-01

    It has been shown that exposure of subjects to emissions from a metal inert gas (MIG) brazing process of zinc-coated material led to an increase of high-sensitivity C-reactive protein (hsCRP) in the blood. In this study, the no-observed-effect level (NOEL) for such emissions was assessed. Twelve healthy subjects were exposed for 6 hours to different concentrations of MIG brazing fumes under controlled conditions. High-sensitivity C-reactive protein was measured in the blood. For welding fumes containing 1.20 and 1.50 mg m zinc, high-sensitivity C-reactive protein was increased the day after exposure. For 0.90 mg m zinc, no increase was detected. These data indicate that the no-observed-effect level for emissions from a MIG brazing process of zinc-coated material in respect to systemic inflammation is found for welding fumes with zinc concentrations between 0.90 and 1.20 mg m.

  13. Building No. 905, showing typical aqua medias or rain hoods ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Building No. 905, showing typical aqua medias or rain hoods - Presidio of San Francisco, Enlisted Men's Barracks Type, West end of Crissy Field, between Pearce & Maudlin Streets, San Francisco, San Francisco County, CA

  14. [Organic brain damage in garage workers after long-term exposure to diesel exhaust fumes].

    PubMed

    Jensen, L K; Klausen, H; Elsnab, C

    1989-09-04

    Diesel motors are employed to an increasing extent for occupational transport and fumes from diesel driven vehicles constitute an increasing problem as regards atmospheric pollution but, in particular, they constitute a considerable risk to health for the workers exposed to diesel exhaust fumes in their daily work. In the clinic for occupational medicine, The University Hospital, Copenhagen, 14 garage workers were examined. Eleven of these had been exposed to great quantities of diesel exhaust fumes for 2 to 29 years. All 11 presented acute symptoms due to diesel exhaust fumes in the form of headache, vertigo, fatigue, irritation of mucous membranes, nausea, abdominal discomfort or diarrhoea. Seven persons had been employed for more than five years as garage workers. Six complained of failure of memory, difficulty in concentration, irritability, increased sleep requirement, psychological changes or reduced libido. Neuropsychological examination was undertaken in these six persons and in five of them organic brain damage, mainly of slight extent, was demonstrated. Diesel exhaust fumes contain many toxic substances: carbon monoxide, nitrous gases, sulphur oxides, aldehydes and hydrocarbons. It is not possible to indicate a single compound which is responsible for possible brain damage and a combination effect may well be concerned. This is a casuistic material. Only few investigations have previously been available which illustrated a possible connection between the neurotoxic effects and, in particular, brain damage. It is now considered important to emphasize that this may constitute a problem on exposure to diesel exhaust fumes.(ABSTRACT TRUNCATED AT 250 WORDS)

  15. Data Management of Watershed Information and Data Enterprise Repository Implementation at Fort Hood, Texas

    DTIC Science & Technology

    2003-03-01

    is a 20-ft (6.1-m) mast supporting a cell phone antenna and a solar panel. Contained with in the enclosure is a Forest Technology Systems data...logger, a deep cycle battery, a voltage regulator, a cell phone modem, and a Motorola cell phone . The stream level, turbidity, and soil moisture sensors...DOIM) Security Protocols at Fort Hood, computers connected to the Fort Hood network cannot utilize cell phone communication to retrieve the data

  16. [Evaluation of measurement uncertainty of welding fume in welding workplace of a shipyard].

    PubMed

    Ren, Jie; Wang, Yanrang

    2015-12-01

    To evaluate the measurement uncertainty of welding fume in the air of the welding workplace of a shipyard, and to provide quality assurance for measurement. According to GBZ/T 192.1-2007 "Determination of dust in the air of workplace-Part 1: Total dust concentration" and JJF 1059-1999 "Evaluation and expression of measurement uncertainty", the uncertainty for determination of welding fume was evaluated and the measurement results were completely described. The concentration of welding fume was 3.3 mg/m(3), and the expanded uncertainty was 0.24 mg/m(3). The repeatability for determination of dust concentration introduced an uncertainty of 1.9%, the measurement using electronic balance introduced a standard uncertainty of 0.3%, and the measurement of sample quality introduced a standard uncertainty of 3.2%. During the determination of welding fume, the standard uncertainty introduced by the measurement of sample quality is the dominant uncertainty. In the process of sampling and measurement, quality control should be focused on the collection efficiency of dust, air humidity, sample volume, and measuring instruments.

  17. 49 CFR 571.113 - Standard No. 113; Hood latch system.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    .... Application. This standard applies to passenger cars, multipurpose passenger vehicles, trucks, and buses. S3... engine, luggage, storage, or battery compartment. S4. Requirements. S4.1Each hood must be provided with a...

  18. 49 CFR 571.113 - Standard No. 113; Hood latch system.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    .... Application. This standard applies to passenger cars, multipurpose passenger vehicles, trucks, and buses. S3... engine, luggage, storage, or battery compartment. S4. Requirements. S4.1Each hood must be provided with a...

  19. 49 CFR 571.113 - Standard No. 113; Hood latch system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    .... Application. This standard applies to passenger cars, multipurpose passenger vehicles, trucks, and buses. S3... engine, luggage, storage, or battery compartment. S4. Requirements. S4.1Each hood must be provided with a...

  20. 49 CFR 571.113 - Standard No. 113; Hood latch system.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    .... Application. This standard applies to passenger cars, multipurpose passenger vehicles, trucks, and buses. S3... engine, luggage, storage, or battery compartment. S4. Requirements. S4.1Each hood must be provided with a...

  1. 49 CFR 571.113 - Standard No. 113; Hood latch system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... Application. This standard applies to passenger cars, multipurpose passenger vehicles, trucks, and buses. S3... engine, luggage, storage, or battery compartment. S4. Requirements. S4.1Each hood must be provided with a...

  2. Population sizes and group characteristics of Siberian Crane (Leucogeranus leucogeranus) and Hooded Crane (Grus monacha) in Poyang Lake Wetland

    PubMed Central

    SHAO, Ming-Qin; GUO, Hong; JIANG, Jian-Hong

    2014-01-01

    Both the Siberian Crane (Leucogeranus leucogeranus) and Hooded Crane (Grus monacha) have limited population sizes and are considered endangered by domestic Chinese and international agencies. To document the current size of their respective populations and characterize their groups, between October 2012 and April 2013 we undertook fieldwork at four nature reserve areas within the Poyang Lake wetlands. We divided Poyanghu National Nature Reserve (PYH) into the Wucheng (PWC) and Hengfeng areas (PHF), because each are each located in different counties. Our fieldwork showed that the Siberian Crane occurred mainly in PYH (364 in the PHF, 158 in the PWC) and the Nanjishan Wetland National Nature Reserve (NJS, with 200 individuals). The Hooded Crane was mainly distributed in PYH (302 in the PHF and 154 in the PWC). Family groups accounted for more than 50% of the total number of groups among both species, with Hooded Cranes forming more family groups than Siberian Cranes. Typically, these groups were formed of two adults with one offspring (Siberian Crane), and two adults with two offspring (Hooded Crane), with the mean family group size of the Siberian Crane and Hooded Crane being respectively 2.65±0.53 (n=43) and 3.09±0.86 (n=47) individuals per group. The mean collective group size of the Siberian Crane and Hooded Crane included 28.09±24.94 (n=23) and 28.94±27.97 (n=16) individuals per group, respectively, with the proportion of juveniles among Hooded Cranes being more than double that seen among the Siberian Cranes. PMID:25297076

  3. Speciation of hexavalent chromium in welding fumes interference by air oxidation of chromium.

    PubMed

    Zatka, V J

    1985-06-01

    The determination of various chromium species in welding fume normally involves digestion in a hot alkaline solution. This work confirms that Cr(III) can be oxidized to Cr(VI) during this digestion. However, only dissolved forms of Cr(III), such as the hydroxochromate(III) ion, [Cr(OH)4], are susceptible to oxidation under these conditions. The air oxidation of Cr(III) can be prevented by hydrolytic destabilization of the hydroxochromate(III) complex by the presence of magnesium hydroxide precipitate. The procedure has been used successfully in the determination of insoluble chromium(VI) in welding fumes. Excellent reproducibility is documented for soluble and insoluble chromium(VI) fractions in the analysis of a bulk sample of welding fume.

  4. Unsterblicher Robin Hood--Eine literaturdidaktische Betrachtung und Wertung von zwoelf Lektueretexten (Immortal Robin Hood--A Pedagogical Consideration and Evaluation of Twelve Reading Texts).

    ERIC Educational Resources Information Center

    Hoegel, Rolf

    1979-01-01

    Examines 12 reading texts about Robin Hood, with regard to their content, suitability for various age levels, and language difficulty. The texts are found to be best suited for grades 5 and 6. An evaluation of each text is included. (IFS/WGA)

  5. The Use of Wetting Agents/Fume Supressants for Minimizing the Atmospheric Emissions from Hard Chromium Electroplating Baths

    DTIC Science & Technology

    2003-08-01

    ESTCP FINAL REPORT For THE USE OF WETTING AGENTS/ FUME SUPPRESSANTS FOR MINIMIZING THE ATMOSPHERIC EMISSIONS FROM HARD CHROMIUM ...Introduction This project demonstrates that a “third” generation wetting agent / fume suppressant (WA/FS) chemical additive to hard chromium ...DOD operations fall in the same category.) Several papers, including Use of Fume Suppressants in Hard Chromium Baths - Quality Testing and Use

  6. Process Development for the Fabrication of Spheroidal Microdevice Packages Utilizing MEMS Technologies

    DTIC Science & Technology

    2014-03-27

    in a thin conductive layer, the wafer surface can be made into the cathode while using a stainless steel plate as an anode. Bath temperature, voltage...beakers with polytetrafluoroethylene (PTFE) tools while under a fume hood, as HF is known to attack glass and polystyrene [62]. Additionally

  7. A study of the bio-accessibility of welding fumes.

    PubMed

    Berlinger, Balázs; Ellingsen, Dag G; Náray, Miklós; Záray, Gyula; Thomassen, Yngvar

    2008-12-01

    The respiratory bio-accessibility of a substance is the fraction that is soluble in the respiratory environment and is available for absorption. In the case of respiratory exposure the amount of absorbed substance plays a main role in the biological effects. Extensive bio-accessibility studies have always been an essential requirement for a better understanding of the biological effects of different workplace aerosols, such as welding fumes. Fumes generated using three different welding techniques, manual metal arc (MMA) welding, metal inert gas (MIG) welding, and tungsten inert gas (TIG) welding were investigated in the present study. Each technique was used for stainless steel welding. Welding fumes were collected on PVC membrane filters in batches of 114 using a multiport air sampler. Three different fluids were applied for the solubility study: deionised water and two kinds of lung fluid simulants: lung epithelial lining fluid simulant (Gamble's solution) and artificial lung lining fluid simulant (Hatch's solution). In order to obtain sufficient data to study the tendencies in solubility change with time, seven different leaching periods were used (0.5, 1, 2, 4, 8, 16, 24 h), each of them with three replicates. The effect of dissolution temperature was also studied. The total amounts of selected metals in the three different welding fumes were determined after microwave-assisted digestion with the mixture of aqua regia and hydrofluoric acid. The most obvious observation yielded by the results is that the solubility of individual metals varies greatly depending on the welding technique, the composition of the leaching fluid and leaching time. This study shows that the most reasonable choice as a media for the bio-assessment of solubility might be Hatch's solution by a dissolution time of 24 h.

  8. Cognitive Control Dysfunction in Workers Exposed to Manganese-Containing Welding Fume

    PubMed Central

    Al-Lozi, A; Nielsen, SS; Hershey, T; Birke, A; Checkoway, H; Criswell, SR; Racette, BA

    2017-01-01

    Background Chronic exposure to manganese (Mn) is a health concern in occupations such as welding because of well-established motor effects due to basal ganglia dysfunction. We hypothesized that cognitive control (the ability to monitor, manipulate, and regulate ongoing cognitive demands) would also be affected by chronic Mn exposure. Methods We examined the relationship between Mn exposure and cognitive control performance in 95 workers with varying intensity and duration (median 15.5 years) of exposure to welding fume. We performed linear regression to assess the association between exposure to Mn-containing welding fume and cognitive control tasks. Results Overall performance was inversely related to intensity of welding exposure (p=0.009) and was driven by the Two-Back and Letter Number Sequencing tests that assess working memory (both p=0.02). Conclusions Occupational exposure to Mn-containing welding fume may be associated with poorer working memory performance, and workers may benefit from practices that reduce exposure intensity. PMID:27862095

  9. Use of CFD for static sampling hood design: An example for methane flux assessment on landfill surfaces.

    PubMed

    Lucernoni, Federico; Rizzotto, Matteo; Tapparo, Federica; Capelli, Laura; Sironi, Selena; Busini, Valentina

    2016-11-01

    The work focuses on the principles for the design of a specific static hood and on the definition of an optimal sampling procedure for the assessment of landfill gas (LFG) surface emissions. This is carried out by means of computational fluid dynamics (CFD) simulations to investigate the fluid dynamics conditions of the hood. The study proves that understanding the fluid dynamic conditions is fundamental in order to understand the sampling results and correctly interpret the measured concentration values by relating them to a suitable LFG emission model, and therefore to estimate emission rates. For this reason, CFD is a useful tool for the design and evaluation of sampling systems, among others, to verify the fundamental hypotheses on which the mass balance for the sampling hood is defined. The procedure here discussed, which is specific for the case of the investigated landfill, can be generalized to be applied also to different scenarios, where hood sampling is involved. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Hooded Warbler Nesting Success Adjacent to Group-selection and Clearcut Edges in a Southeastern Bottomland Forest

    Treesearch

    Christopher E. Moorman; David C. Guynn; John C. Kilgo

    2002-01-01

    During the 1996, 1997, and 199X breeding seasons, WC located and monitored Hooded Warbler (Wilsonia citrina) nests in a bottomland forest and examined the effects of edge proximity, edge type, and nest-site vegetation on nesting success. SW- cessful Hooded Warbler nests were more concealed from below and were located in nest patches with a greater...

  11. Characterization of Tungsten Inert Gas (TIG) Welding Fume Generated by Apprentice Welders.

    PubMed

    Graczyk, Halshka; Lewinski, Nastassja; Zhao, Jiayuan; Concha-Lozano, Nicolas; Riediker, Michael

    2016-03-01

    Tungsten inert gas welding (TIG) represents one of the most widely used metal joining processes in industry. Its propensity to generate a greater portion of welding fume particles at the nanoscale poses a potential occupational health hazard for workers. However, current literature lacks comprehensive characterization of TIG welding fume particles. Even less is known about welding fumes generated by welding apprentices with little experience in welding. We characterized TIG welding fume generated by apprentice welders (N = 20) in a ventilated exposure cabin. Exposure assessment was conducted for each apprentice welder at the breathing zone (BZ) inside of the welding helmet and at a near-field (NF) location, 60cm away from the welding task. We characterized particulate matter (PM4), particle number concentration and particle size, particle morphology, chemical composition, reactive oxygen species (ROS) production potential, and gaseous components. The mean particle number concentration at the BZ was 1.69E+06 particles cm(-3), with a mean geometric mean diameter of 45nm. On average across all subjects, 92% of the particle counts at the BZ were below 100nm. We observed elevated concentrations of tungsten, which was most likely due to electrode consumption. Mean ROS production potential of TIG welding fumes at the BZ exceeded average concentrations previously found in traffic-polluted air. Furthermore, ROS production potential was significantly higher for apprentices that burned their metal during their welding task. We recommend that future exposure assessments take into consideration welding performance as a potential exposure modifier for apprentice welders or welders with minimal training. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  12. Exposure to Cooking Fumes and Acute Reversible Decrement in Lung Functional Capacity.

    PubMed

    Neghab, Masoud; Delikhoon, Mahdieh; Norouzian Baghani, Abbas; Hassanzadeh, Jafar

    2017-10-01

    Being exposed to cooking fumes, kitchen workers are occupationally at risk of multiple respiratory hazards. No conclusive evidence exists as to whether occupational exposure to these fumes is associated with acute and chronic pulmonary effects and symptoms of respiratory diseases. To quantify the exposure levels and evaluate possible chronic and acute pulmonary effects associated with exposure to cooking fumes. In this cross-sectional study, 60 kitchen workers exposed to cooking fumes and 60 unexposed employees were investigated. The prevalence of respiratory symptoms among these groups was determined through completion of a standard questionnaire. Pulmonary function parameters were also measured before and after participants' work shift. Moreover, air samples were collected and analyzed to quantify their aldehyde, particle, and volatile organic contents. The mean airborne concentrations of formaldehyde, acetaldehyde, and acrolein was 0.45 (SD 0.41), 0.13 (0.1), and 1.56 (0.41) mg/m 3 , respectively. The mean atmospheric concentrations of PM 1 , PM 2.5 , PM 7 , PM 10 , and total volatile organic compounds (TVOCs) was 3.31 (2.6), 12.21 (5.9), 44.16 (16.6), 57 (21.55) μg/m 3 , and 1.31 (1.11) mg/m 3 , respectively. All respiratory symptoms were significantly (p<0.05) more prevalent in exposed group. No significant difference was noted between the pre-shift mean of spirometry parameters of exposed and unexposed group. However, exposed workers showed cross-shift decrease in most spirometry parameters, significantly lower than the pre-shift values and those of the comparison group. Exposure to cooking fumes is associated with a significant increase in the prevalence of respiratory symptoms as well as acute reversible decrease in lung functional capacity.

  13. Investigating Annual Diving Behaviour by Hooded Seals (Cystophora cristata) within the Northwest Atlantic Ocean

    PubMed Central

    Andersen, Julie M.; Skern-Mauritzen, Mette; Boehme, Lars; Wiersma, Yolanda F.; Rosing-Asvid, Aqqalu; Hammill, Mike O.; Stenson, Garry B.

    2013-01-01

    With the exception of relatively brief periods when they reproduce and moult, hooded seals, Cystophora cristata, spend most of the year in the open ocean where they undergo feeding migrations to either recover or prepare for the next fasting period. Valuable insights into habitat use and diving behaviour during these periods have been obtained by attaching Satellite Relay Data Loggers (SRDLs) to 51 Northwest (NW) Atlantic hooded seals (33 females and 18 males) during ice-bound fasting periods (2004−2008). Using General Additive Models (GAMs) we describe habitat use in terms of First Passage Time (FPT) and analyse how bathymetry, seasonality and FPT influence the hooded seals’ diving behaviour described by maximum dive depth, dive duration and surface duration. Adult NW Atlantic hooded seals exhibit a change in diving activity in areas where they spend >20 h by increasing maximum dive depth, dive duration and surface duration, indicating a restricted search behaviour. We found that male and female hooded seals are spatially segregated and that diving behaviour varies between sexes in relation to habitat properties and seasonality. Migration periods are described by increased dive duration for both sexes with a peak in May, October and January. Males demonstrated an increase in dive depth and dive duration towards May (post-breeding/pre-moult) and August–October (post-moult/pre-breeding) but did not show any pronounced increase in surface duration. Females dived deepest and had the highest surface duration between December and January (post-moult/pre-breeding). Our results suggest that the smaller females may have a greater need to recover from dives than that of the larger males. Horizontal segregation could have evolved as a result of a resource partitioning strategy to avoid sexual competition or that the energy requirements of males and females are different due to different energy expenditure during fasting periods. PMID:24282541

  14. Inflammatory responses to the occupational inhalation of metal fume.

    PubMed

    Palmer, K T; McNeill Love, R M C; McNeill-Love, R; Poole, J R; Coggon, D; Frew, A J; Linaker, C H; Shute, J K

    2006-02-01

    Occupational exposure to metal fume promotes a reversible increase in the risk of pneumonia, but by mechanisms which are unclear. To investigate, the current authors measured various markers of host defence function in welders and nonwelders. Induced sputum and venous blood samples were collected from 27 welders with regular long-term exposure to ferrous metal fume and 31 unexposed matched controls. In sputum, the present authors measured cell counts, the soluble and cellular iron concentration, and levels of interleukin-8, tumour necrosis factor-alpha, myeloperoxidase, matrix metalloproteinase-9, immunoglobulin (Ig)A, alpha(2)-macroglobulin and unsaturated iron-binding capacity. Blood samples were assayed for evidence of neutrophil activation and pneumococcal IgG antibodies. Welders had significantly higher iron levels and a substantially lower unsaturated iron-binding capacity in their sputum, but, despite a high iron challenge, there was a noteworthy absence of an inflammatory response. Only blood counts of eosinophils and basophils were significantly related to the extent of welding. Weak nonsignificant trends were observed for several other measures, consistent with low-grade priming of neutrophils. In conclusion, these data suggest that chronic exposure to metal fume blunts responsiveness to inhaled particulate matter. However, the mechanism behind the lack of detectable local inflammatory response requires further investigation.

  15. Fluorescence development of fingerprints by combining conjugated polymer nanoparticles with cyanoacrylate fuming.

    PubMed

    Chen, Hong; Ma, Rong-Liang; Fan, Zhinan; Chen, Yun; Wang, Zizheng; Fan, Li-Juan

    2018-05-23

    Selecting appropriate developing methods/reagents or their combination to enhance the effect for fingerprint development is of great significance for practical forensic investigation. Ethyl-2-cyanoacrylate ester (superglue) fuming is a popular method for "in-situ" developing fingerprints in forensic science, followed by fluorescence staining to enhance the contrast of the fingerprint image in some occasion. In this study, a series of fluorescent poly(p-phenylene vinylene) (PPV) nanoparticles (NPs) in colloidal solution were successfully prepared and the emission color was tuned via a simple way. The fuming process was carried out using a home-made device. The staining was accomplished by immersing a piece of absorbent cotton into the solution of NPs, and then gently applied on the fumed fingerprints for several times. The PPV NPs were found to have a better developing effect than Rhodamine 6G when excited by 365 nm UV lamp. Different emission colors of NPs are advantageous in developing fingerprints on various substrates. Mechanism study suggested that the NPs were embedded in the porous structure of the superglue resin. In all, the combination of fuming method with the staining by conjugated polymer NPs has been demonstrated to be successful for fluorescent fingerprint development and be promising for more practical forensic applications. Copyright © 2018. Published by Elsevier Inc.

  16. Low Temperature Synthesis of Belite Cement Based on Silica Fume and Lime.

    PubMed

    Tantawy, M A; Shatat, M R; El-Roudi, A M; Taher, M A; Abd-El-Hamed, M

    2014-01-01

    This paper describes the low temperature synthesis of belite (β-C2S) from silica fume. Mixtures of lime, BaCl2, and silica fume with the ratio of (Ca + Ba)/Si = 2 were hydrothermally treated in stainless steel capsule at 110-150°C for 2-5 hours, calcined at 600-700°C for 3 hours, and analyzed by FTIR, XRD, TGA/DTA, and SEM techniques. Dicalcium silicate hydrate (hillebrandite) was prepared by hydrothermal treatment of lime/silica fume mixtures with (Ca + Ba)/Si = 2 at 110°C for 5 hours. Hillebrandite partially dehydrates in two steps at 422 and 508°C and transforms to γ-C2S at 734°C which in turn transforms to α'-C2S at 955°C which in turn transforms to β-C2S when cooled. In presence of Ba(2+) ions, β-C2S could be stabilized with minor transformation to γ-C2S. Mixture of silica fume, lime, and BaCl2 with the ratio of (Ca + Ba)/Si = 2 was successfully utilized for synthesis of β-C2S by hydrothermal treatment at 110°C for 5 hours followed by calcination of the product at 700°C for 3 hours.

  17. Assessment of outer hair cell function and blood antioxidant status of rabbits exposed to noise and metal welding fumes.

    PubMed

    Mirzaee, Ramazan; Allameh, Abdolamir; Mortazavi, Seyed Bagher; Khavanin, Ali; Kazemnejad, Anoshirvan; Akbary, Mehdi

    2007-06-01

    To investigate the interaction between welding fumes and noise in causation of hearing impairment. Groups of rabbits (n=6) were exposed to noise, welding fumes or combination of both prior to Distortion Product Otoacoustic-Emissions (DPOAEs) analysis. The function of outer hair cells (OHCs) was examined by DPOAE assessment over a broad range of frequencies. Variations in DPOAE amplitude were compared between control (n=6) and exposed (n=18) groups. The DPOAEs levels measured at different frequencies (1379-6299 Hz) were found to decrease significantly (P<0.05) in rabbits exposed to 110 dB sound pressure level (SPL) broadband noise (8h/day, 12 days). In rabbits, exposed to carbon-steel welding fumes alone (157 mg/m(3)), the threshold shift was limited to the high frequencies (2759-6299 Hz), whereas, mixed exposure to noise and fumes resulted in reduction of DPOAEs at all the frequencies. Changes in DPOAEs were associated with increased susceptibility of erythrocytes to oxidation (P<0.05). Exposure to noise or fumes alone or simultaneously, suppressed total antioxidant ability of plasma as measured by ferric reducing ability of plasma (FRAP). Noise alone or in combination with fumes resulted in depletion of blood glutathione (GSH). Despite suppression of FRAP in the exposed groups, GSH was found to remain unchanged due to welding fumes suggesting that antioxidants other than GSH are affected by toxicants present in metal welding fumes. Exposure to very high levels of welding fumes can increase noise-related effects on OHC function by extending hearing threshold shift to wide band frequencies.

  18. Dynamic Moisture Sorption and Desorption in Fumed Silica-filled Silicone Foam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trautschold, Olivia Carol

    Characterizing dynamic moisture sorption and desorption in fumed silica-filled silicone foam is necessary for determining material compatibilities and life predictions, particularly in sealed environments that may be exposed to a range of environmental conditions. Thermogravimetric analysis (TGA) and near infrared spectroscopy (NIR) were performed on S5470 fumed silica-filled silicone foam to determine the weight percent of moisture at saturation. Additionally, TGA was used to determine the time, temperature, and relative humidity levels required for sorption and desorption of physisorbed moisture in S5470.

  19. Don Quixote, Machiavelli, and Robin Hood: public health practice, past and present.

    PubMed Central

    Mullan, F

    2000-01-01

    Since the mid-19th century, when the first formal health departments were established in the United States, commissioners, directors, and secretaries of public health have functioned as senior members of the staffs of public executives, mayors, governors, and presidents. They have provided important political, managerial, and scientific leadership to agencies of government that have played increasingly important roles in national life, from the sanitary revolution of the 19th century to the prevention of HIV/AIDS and the control of tobacco use today. Although public health officials come from a variety of backgrounds and oversee agencies of varied size and composition, there are philosophical themes that describe and define the commonality of their work. These themes are captured metaphorically by 3 celebrated figures: Don Quixote, Machiavelli, and Robin Hood. By turns, the public health official functions as a determined idealist (Don Quixote), a cunning political strategist (Machiavelli), and an agent who redistributes resources from the wealthier sectors of society to the less well off (Robin Hood.) All 3 personae are important, but, it is argued, Robin Hood is the most endangered. PMID:10800417

  20. DETAIL OF EAVES AND HOODS OVER WINDOWS ON NORTHEAST END ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    DETAIL OF EAVES AND HOODS OVER WINDOWS ON NORTHEAST END OF NORTHWEST SIDE, WITH SEABEE STATUE IN BACKGROUND. - U.S. Naval Base, Pearl Harbor, Joint Intelligence Center, Makalapa Drive in Makalapa Administration Area, Pearl City, Honolulu County, HI

  1. Transportation observations, considerations and recommendations for Mt. Hood National Forest

    DOT National Transportation Integrated Search

    2009-06-24

    A field investigation of the current transportation infrastructure and operations at Mt. Hood : National Forest (MHNF) by the interagency Transportation Assistance Group (TAG) was conducted June : 24-26, 2009, on behalf of the U.S. Forest Service (US...

  2. Personal exposure to metal fume, NO2, and O3 among production welders and non-welders.

    PubMed

    Schoonover, Todd; Conroy, Lorraine; Lacey, Steven; Plavka, Julie

    2011-01-01

    The objective of this study was to characterize personal exposures to welding-related metals and gases for production welders and non-welders in a large manufacturing facility. Welding fume metals and irritant gases nitrogen dioxide (NO(2)) and ozone (O(3)) were sampled for thirty-eight workers. Personal exposure air samples for welding fume metals were collected on 37 mm open face cassettes and nitrogen dioxide and ozone exposure samples were collected with diffusive passive samplers. Samples were analyzed for metals using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) and welding fume metal exposure concentrations were defined as the sum of welding-related metals mass per volume of air sampled. Welding fume metal exposures were highly variable among similar types of welding while NO(2) and O(3) exposure were less variable. Welding fume metal exposures were significantly higher 474 μg/m(3) for welders than non-welders 60 μg/m(3) (p=0.001). Welders were exposed to higher concentrations of NO(2) and O(3) than non-welders but the differences were not statistically significant. Welding fume metal exposure concentrations for welders performing gas metal arc welding (GMAW) and shielded metal arc welding (SMAW) were higher than welders performing gas tungsten arc welding (GTAW). Non-welders experienced exposures similar to GTAW welders despite a curtain wall barrier separating welding and non-welding work areas.

  3. Decommissioning of Active Ventilation Systems in a Nuclear R and D Facility to Prepare for Building Demolition (Whiteshell Laboratories Decommissioning Project, Canada) - 13073

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilcox, Brian; May, Doug; Howlett, Don

    2013-07-01

    Whiteshell Laboratories (WL) is a nuclear research establishment owned by the Canadian government and operated by Atomic Energy of Canada Limited (AECL) since the early 1960's. WL is currently under a decommissioning license and the mandate is to remediate the nuclear legacy liabilities in a safe and cost effective manner. The WL Project is the first major nuclear decommissioning project in Canada. A major initiative underway is to decommission and demolish the main R and D Laboratory complex. The Building 300 R and D complex was constructed to accommodate laboratories and offices which were mainly used for research and developmentmore » associated with organic-cooled reactors, nuclear fuel waste management, reactor safety, advanced fuel cycles and other applications of nuclear energy. Building 300 is a three storey structure of approximately 16,000 m{sup 2}. In order to proceed with building demolition, the contaminated systems inside the building have to be characterized, removed, and the waste managed. There is a significant focus on volume reduction of radioactive waste for the WL project. The active ventilation system is one of the significant contaminated systems in Building 300 that requires decommissioning and removal. The active ventilation system was designed to manage hazardous fumes and radioactivity from ventilation devices (e.g., fume hoods, snorkels and glove boxes) and to prevent the escape of airborne hazardous material outside of the laboratory boundary in the event of an upset condition. The system includes over 200 ventilation devices and 32 active exhaust fan units and high efficiency particulate air (HEPA) filters. The strategy to remove the ventilation system was to work from the laboratory end back to the fan/filter system. Each ventilation duct was radiologically characterized. Fogging was used to minimize loose contamination. Sections of the duct were removed by various cutting methods and bagged for temporary storage prior to

  4. Changes in Physiologic Parameters and Effects of Hooding in Red-tailed Hawks ( Buteo jamaicensis ) During Manual Restraint.

    PubMed

    Doss, Grayson A; Mans, Christoph

    2016-06-01

    Manual restraint in birds of prey is required for many veterinary and research procedures. To investigate the effects of handling stress on physiologic parameters in raptorial birds, 8 red-tailed hawks ( Buteo jamaicensis ) were manually restrained over a 15-minute period. Respiratory rate (RR), heart rate (HR), and cloacal temperature were monitored over time and recorded at defined intervals during the experiment. The effect of hooding on physiologic variables was also evaluated in a complete crossover design. Both RR and HR decreased significantly during the 15-minute restraint period (HR, -80 ± 101.4 beats/min [bpm], [P < .01]; RR, -17.5 ± 22.6 breaths/min, [P < .05]). Hooded birds had significantly lower HRs and RRs at 15 minutes of restraint (HR: 232.5 ± 26 bpm, [P < .037]; RR: 33.1 ± 6.7 breaths/min, [P < .05]) compared to birds restrained without a hood (HR: 280 ± 74.1 bpm; RR: 51.5 ± 28.8 breaths/min). Cloacal temperature increased significantly in all manually restrained birds (+2.2 ± 0.7°C, [P < .01]), with a comparable increase in hooded and nonhooded birds. In this study of the effects of manual restraint on red-tailed hawks, hooding versus nonhooding amplified the decrease in HR and RR but had no effect on stress-induced hyperthermia.

  5. Hooded warbler in North Dakota

    USGS Publications Warehouse

    Hotchkiss, N.

    1943-01-01

    he 1942 warbler migration at Kenmare, Ward County, North Dakota, was rich in species (seventeen) for a locality so far west on the Great Plains. On June 1, near the end of the northward flight, I found a male Hooded Warbler singing in shrubby undergrowth on a wooded coulee slope on the Des Lacs National Wildlife Refuge, about two miles south of Kenmare. The bird was observed at close range for several minutes, both without and with 7-power binoculars. It behaved as in the vicinity of Washington, D. C., where I have been familiar with the species for several years, the song being vigorous and loud and the movements leisurely.

  6. Interstitial lung disease due to fumes from heat-cutting polymer rope.

    PubMed

    Sharman, P; Wood-Baker, R

    2013-09-01

    Interstitial lung disease (ILD) due to inhalation of fume/smoke from heating or burning of synthetic polymers has not been reported previously. A fish farm worker developed ILD after cutting rope (polypropylene and nylon) for about 2 hours per day over an extended period using an electrically heated 'knife'. This process produced fume/smoke that entered the workers breathing zone. No other likely cause was identified. This case suggests that exposure to airborne contaminants generated by the heating or burning of synthetic polymers has the potential to cause serious lung disease.

  7. Testing Silica Fume-Based Concrete Composites under Chemical and Microbiological Sulfate Attacks

    PubMed Central

    Estokova, Adriana; Kovalcikova, Martina; Luptakova, Alena; Prascakova, Maria

    2016-01-01

    Current design practices based on descriptive approaches to concrete specification may not be appropriate for the management of aggressive environments. In this study, the durability of cement-based materials with and without the addition of silica fume, subjected to conditions that leach calcium and silicon, were investigated. Chemical corrosion was simulated by employing various H2SO4 and MgSO4 solutions, and biological corrosion was simulated using Acidithiobacillus sp. bacterial inoculation, leading to disrupted and damaged surfaces; the samples’ mass changes were studied following both chemical and biological attacks. Different leaching trends were observed via X-ray fluorescence when comparing chemical with biological leaching. Lower leaching rates were found for concrete samples fortified with silica fume than those without silica fume. X-ray diffraction and scanning electron microscopy confirmed a massive sulfate precipitate formation on the concrete surface due to bacterial exposure. PMID:28773452

  8. Effects of Exposure to Welding Fume on Lung Function: Results from the German WELDOX Study.

    PubMed

    Lehnert, M; Hoffmeyer, F; Gawrych, K; Lotz, A; Heinze, E; Berresheim, H; Merget, R; Harth, V; Van Gelder, R; Hahn, J-U; Hartwig, A; Weiß, T; Pesch, B; Brüning, T

    2015-01-01

    The association between exposure to welding fume and chronic obstructive pulmonary disease (COPD) has been insufficiently clarified. In this study we assessed the influence of exposure to welding fume on lung function parameters. We investigated forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), FEV1/FVC, and expiratory flow rates in 219 welders. We measured current exposure to respirable particles and estimated a worker's lifetime exposure considering welding techniques, working conditions and protective measures at current and former workplaces. Multiple regression models were applied to estimate the influence of exposure to welding fume, age, and smoking on lung function. We additionally investigated the duration of working as a welder and the predominant welding technique. The findings were that age- and smoking-adjusted lung function parameters showed no decline with increasing duration, current exposure level, and lifetime exposure to welding fume. However, 15% of the welders had FEV1/FVC below the lower limit of normal, but we could not substantiate the presence of an association with the measures of exposure. Adverse effects of cigarette smoking were confirmed. In conclusion, the study did not support the notion of a possible detrimental effect of exposure to welding fume on lung function in welders.

  9. 81. Neg. No. F63, Apr 13, 1930, INTERIORASSEMBLY BUILDING, HOOD ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    81. Neg. No. F-63, Apr 13, 1930, INTERIOR-ASSEMBLY BUILDING, HOOD DEPARTMENT - Ford Motor Company Long Beach Assembly Plant, Assembly Building, 700 Henry Ford Avenue, Long Beach, Los Angeles County, CA

  10. Flow characteristics and spillage mechanisms of wall-mounted and jet-isolated range hoods subject to influence from cross draft.

    PubMed

    Chen, Jia-Kun; Huang, Rong Fung; Peng, Kuan-Lin

    2012-01-01

    The effects of draft on the flow and spillage characteristics of wall-mounted and jet-isolated range hoods were investigated. A specially designed draft generator that could supply low-swirl air current was used to provide "cross draft" from three directions, lateral (θ = 0(o)), oblique (θ = 45(o)), and front (θ = 90(o)), with respect to the center point of the range hoods. Flow characteristics of oil mist were inspected through visualization of smoke flows with light scattering (laser light sheet-assisted visualization of smoke flow). The leakage mechanisms, which were closely related to the flow features, were studied by examining both movies and still pictures showing smoke-flow evolution. The sulfur hexafluoride tracer gas concentration detection method was employed to measure the capture indices. The results showed that the lateral draft pushed the pollutants generated under the hood in the opposite direction and induced serious spillage. The oblique draft pushed the pollutants toward both the rear wall and opposite side and induced more serious spillage than did the lateral draft. The frontal draft forced the pollutants to bifurcate into streams moving toward the left and the right, and induced the most serious pollutant spillage among the three tested drafts. Pollutant spillage became critically significant as the cross draft velocity was increased to greater than 0.2 m/sec. Spillage of pollutants increased as the velocity of the cross draft was increased. Increasing the suction flow rate of the range hood may increase resistance to the draft, but the benefits were limited at draft velocities greater than 0.2 m/sec. Both range hoods had a similarly low capture index under the influence of the lateral draft. For the oblique and frontal drafts, the jet-isolated range hood demonstrated a higher capture index than did the wall-mounted range hood.

  11. Single and Combined Exposure to Zinc- and Copper-Containing Welding Fumes Lead to Asymptomatic Systemic Inflammation.

    PubMed

    Markert, Agnieszka; Baumann, Ralf; Gerhards, Benjamin; Gube, Monika; Kossack, Veronika; Kraus, Thomas; Brand, Peter

    2016-02-01

    Recently, it has been shown that exposure to welding fumes containing both zinc and copper leads to asymptomatic systemic inflammation in humans as shown by an increase of blood C-reactive protein. In the present study, it was investigated which metal is responsible for this effect. Fifteen healthy male subjects were exposed under controlled conditions to welding fumes containing either zinc, or copper, or copper and zinc. For each exposure blood C-reactive protein increased. Copper- and zinc-containing welding fumes are able to induce systemic inflammation.

  12. 42 CFR 84.136 - Facepieces, hoods, and helmets; eyepieces; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... (a) Facepieces, hoods, and helmets shall be designed and constructed to provide adequate vision which... suitable material which does not interfere with the vision of the wearer. (2) Shields shall be mounted and...

  13. 42 CFR 84.136 - Facepieces, hoods, and helmets; eyepieces; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    .... (a) Facepieces, hoods, and helmets shall be designed and constructed to provide adequate vision which... suitable material which does not interfere with the vision of the wearer. (2) Shields shall be mounted and...

  14. Critical evaluation of sequential leaching procedures for the determination of Ni and Mn species in welding fumes.

    PubMed

    Berlinger, B; Náray, M; Sajó, I; Záray, G

    2009-06-01

    In this work, welding fume samples were collected in a welding plant, where corrosion-resistant steel and unalloyed structural steel were welded by gas metal arc welding (GMAW) and manual metal arc welding (MMAW) techniques. The welding fumes were sampled with a fixed-point sampling strategy applying Higgins-Dewell cyclones. The following solutions were used to dissolve the different species of Ni and Mn: ammonium citrate solution [1.7% (m/v) diammonium hydrogen citrate and 0.5% (m/v) citric acid monohydrate] for 'soluble' Ni, 50:1 methanol-bromine solution for metallic Ni, 0.01 M ammonium acetate for soluble Mn, 25% acetic acid for Mn(0) and Mn(2+) and 0.5% hydroxylammonium chloride in 25% acetic acid for Mn(3+) and Mn(4+). 'Insoluble' Ni and Mn contents of the samples were determined after microwave-assisted digestion with the mixture of concentrated (cc). HNO(3), cc. HCl and cc. HF. The sample solutions were analysed by inductively coupled plasma quadrupole mass spectrometry and inductively coupled plasma atomic emission spectrometry. The levels of total Ni and Mn measured in the workplace air were different because of significant differences of the fume generation rates and the distributions of the components in the welding fumes between the welding processes. For quality control of the leaching process, dissolution of the pure stoichiometric Mn and Ni compounds and their mixtures weighing was investigated using the optimized leaching conditions. The results showed the adequacy of the procedure for the pure metal compounds. Based on the extraction procedures, the predominant oxidation states of Ni and Mn proved to be very different depending on the welding techniques and type of the welded steels. The largest amount of Mn in GMAW fumes were found as insoluble Mn (46 and 35% in case of corrosion-resistant steel and unalloyed structural steel, respectively), while MMAW fumes contain mainly soluble Mn, Mn(0) and Mn(2+) (78%) and Mn(3+) and Mn(4+) (54%) in case of

  15. Low Temperature Synthesis of Belite Cement Based on Silica Fume and Lime

    PubMed Central

    Tantawy, M. A.; Shatat, M. R.; El-Roudi, A. M.; Taher, M. A.; Abd-El-Hamed, M.

    2014-01-01

    This paper describes the low temperature synthesis of belite (β-C2S) from silica fume. Mixtures of lime, BaCl2, and silica fume with the ratio of (Ca + Ba)/Si = 2 were hydrothermally treated in stainless steel capsule at 110–150°C for 2–5 hours, calcined at 600–700°C for 3 hours, and analyzed by FTIR, XRD, TGA/DTA, and SEM techniques. Dicalcium silicate hydrate (hillebrandite) was prepared by hydrothermal treatment of lime/silica fume mixtures with (Ca + Ba)/Si = 2 at 110°C for 5 hours. Hillebrandite partially dehydrates in two steps at 422 and 508°C and transforms to γ-C2S at 734°C which in turn transforms to α′-C2S at 955°C which in turn transforms to β-C2S when cooled. In presence of Ba2+ ions, β-C2S could be stabilized with minor transformation to γ-C2S. Mixture of silica fume, lime, and BaCl2 with the ratio of (Ca + Ba)/Si = 2 was successfully utilized for synthesis of β-C2S by hydrothermal treatment at 110°C for 5 hours followed by calcination of the product at 700°C for 3 hours. PMID:27437495

  16. Effect of silica fume on compressive strength of oil-polluted concrete in different marine environments

    NASA Astrophysics Data System (ADS)

    Shahrabadi, Hamid; Sayareh, Sina; Sarkardeh, Hamed

    2017-12-01

    In the present research, effect of silica fume as an additive and oil polluted sands as aggregates on compressive strength of concrete were investigated experimentally. The amount of oil in the designed mixtures was assumed to be constant and equal to 2% of the sand weight. Silica fume accounting for 10%, 15% and 20% of the weight is added to the designed mixture. After preparation and curing, concrete specimens were placed into the three different conditions: fresh, brackish and saltwater environments (submerged in fresh water, alternation of exposed in air & submerged in sea water and submerged in sea water). The result of compressive strength tests shows that the compressive strength of the specimens consisting of silica fume increases significantly in comparison with the control specimens in all three environments. The compressive strength of the concrete with 15% silica fume content was about 30% to 50% higher than that of control specimens in all tested environments under the condition of using polluted aggregates in the designed mixture.

  17. Development of a field method for measuring manganese in welding fume.

    PubMed

    Dale Marcy, A; Drake, Pamela L

    2007-11-01

    Workers who perform routine welding tasks are potentially exposed to fume that may contain manganese. Manganese may cause respiratory problems and is implicated in causing the occurrence of Parkinson-like symptoms. In this study, a field colorimetric method for extracting and measuring manganese in welding fume was developed. The method uses ultrasonic extraction with an acidic hydrogen peroxide solution to extract welding fume collected on polyvinyl chloride filters. Commercially available pre-packaged reagents are used to produce a colored solution, created by a reaction of manganese(ii) with 1-(2-pyridylazo)-2-naphthol. Absorbance measurements are then made using a portable spectrophotometer. The method detection limit and limit of quantification (LOQ) were 5.2 microg filter(-1) and 17 microg filter(-1), respectively, with a dynamic range up to 400 microg filter(-1). When the results are above the LOQ for the colorimetric method, the manganese masses are equivalent to those measured by the International Organization for Standardization Method 15202-2, which employs a strong acid digestion and analysis using inductively coupled plasma-optical emission spectrometry.

  18. Cognitive control dysfunction in workers exposed to manganese-containing welding fume.

    PubMed

    Al-Lozi, Amal; Nielsen, Susan Searles; Hershey, Tamara; Birke, Angela; Checkoway, Harvey; Criswell, Susan R; Racette, Brad A

    2017-02-01

    Chronic exposure to manganese (Mn) is a health concern in occupations such as welding because of well-established motor effects due to basal ganglia dysfunction. We hypothesized that cognitive control (the ability to monitor, manipulate, and regulate ongoing cognitive demands) would also be affected by chronic Mn exposure. We examined the relationship between Mn exposure and cognitive control performance in 95 workers with varying intensity and duration (median 15.5 years) of exposure to welding fume. We performed linear regression to assess the association between exposure to Mn-containing welding fume and cognitive control tasks. Overall performance was inversely related to intensity of welding exposure (P = 0.009) and was driven by the Two-Back and Letter Number Sequencing tests that assess working memory (both P = 0.02). Occupational exposure to Mn-containing welding fume may be associated with poorer working memory performance, and workers may benefit from practices that reduce exposure intensity. Am. J. Ind. Med. 60:181-188, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  19. Fume generation and content of total chromium and hexavalent chromium in flux-cored arc welding.

    PubMed

    Yoon, Chung Sik; Paik, Nam Won; Kim, Jeong Han

    2003-11-01

    This study was performed to investigate the fume generation rates (FGRs) and the concentrations of total chromium and hexavalent chromium when stainless steel was welded using flux-cored arc welding (FCAW) with CO2 gas. FGRs and concentrations of total chromium and hexavalent chromium were quantified using a method recommended by the American Welding Society, inductively coupled plasma-atomic emission spectroscopy (NIOSH Method 7300) and ion chromatography (modified NIOSH Method 7604), respectively. The amount of total fume generated was significantly related to the level of input power. The ranges of FGR were 189-344, 389-698 and 682-1157 mg/min at low, optimal and high input power, respectively. It was found that the FGRs increased with input power by an exponent of 1.19, and increased with current by an exponent of 1.75. The ranges of total chromium fume generation rate (FGRCr) were 3.83-8.27, 12.75-37.25 and 38.79-76.46 mg/min at low, optimal and high input power, respectively. The ranges of hexavalent chromium fume generation rate (FGRCr6+) were 0.46-2.89, 0.76-6.28 and 1.70-11.21 mg/min at low, optimal and high input power, respectively. Thus, hexavalent chromium, which is known to be a carcinogen, generated 1.9 (1.0-2.7) times and 3.7 (2.4-5.0) times as the input power increased from low to optimal and low to high, respectively. As a function of input power, the concentration of total chromium in the fume increased from 1.57-2.65 to 5.45-8.13% while the concentration of hexavalent chromium ranged from 0.15 to 1.08%. The soluble fraction of hexavalent chromium produced by FCAW was approximately 80-90% of total hexavalent chromium. The concentration of total chromium and the solubility of hexavalent chromium were similar to those reported from other studies of shielded metal arc welding fumes, and the concentration of hexavalent chromium was similar to that obtained for metal inert gas-welding fumes.

  20. 5. VIEW OF SITE A FROM SOUTH END OF HOOD, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. VIEW OF SITE A FROM SOUTH END OF HOOD, FACING NORTH (BUILDINGS 117, 120, 122, 116, 128, and 121 ARE VISIBLE.) - Fort McPherson, World War II Station Hospital, Structures, Bordered by Hardee & Thorne Avenues & Howe Street, Atlanta, Fulton County, GA

  1. 29 CFR 1926.57 - Ventilation.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... exhaust ventilation when used as described in (a) shall be designed to prevent dispersion into the air of... shall be so designed that dusts, fumes, mists, vapors, or gases are not drawn through the work area of employees. (c) Design and operation. Exhaust fans, jets, ducts, hoods, separators, and all necessary...

  2. Refinement of Propellant Strand Burning Method to Suit Aluminised Composite Rocket Propellant

    DTIC Science & Technology

    2014-12-01

    from discrete burn rates at each pressure. Strands are ignited with a nickel- chromium (nichrome) wire with burn time measured via timing wires which...Application of Paint Inhibitor 8.5.1 Switch on the fume hood and prepare a 70% dilution of inhibitor paint as per instructions of document 3.5

  3. For White Folks Who Teach (Music) in the Hood

    ERIC Educational Resources Information Center

    Karvelis, Noah J.

    2017-01-01

    In this article, I aim to critically analyze theories contained within Dr. Christopher Emdin's newest book "For White Folks Who Teach in the Hood (and the Rest of Ya'll Too!)" in the context of the music classroom. To begin, I summarize Christopher Emdin's theories of both "reality" and "pentecostal" pedagogy and then…

  4. Size Distribution and Estimated Respiratory Deposition of Total Chromium, Hexavalent Chromium, Manganese, and Nickel in Gas Metal Arc Welding Fume Aerosols

    PubMed Central

    Cena, Lorenzo G.; Chisholm, William P.; Keane, Michael J.; Cumpston, Amy; Chen, Bean T.

    2016-01-01

    A laboratory study was conducted to determine the mass of total Cr, Cr(VI), Mn, and Ni in 15 size fractions for mild and stainless steel gas-metal arc welding (GMAW) fumes. Samples were collected using a nano multi orifice uniform deposition impactor (MOUDI) with polyvinyl chloride filters on each stage. The filters were analyzed by inductively coupled plasma mass spectrometry (ICP-MS) and ion chromatography. Limits of detection (LODs) and quantitation (LOQs) were experimentally calculated and percent recoveries were measured from spiked metals in solution and dry, certified welding-fume reference material. The fraction of Cr(VI) in total Cr was estimated by calculating the ratio of Cr(VI) to total Cr mass for each particle size range. Expected, regional deposition of each metal was estimated according to respiratory-deposition models. The weight percent (standard deviation) of Mn in mild steel fumes was 9.2% (6.8%). For stainless steel fumes, the weight percentages were 8.4% (5.4%) for total Cr, 12.2% (6.5%) for Mn, 2.1% (1.5%) for Ni and 0.5% (0.4%) for Cr(VI). All metals presented a fraction between 0.04 and 0.6 μm. Total Cr and Ni presented an additional fraction <0.03 μm. On average 6% of the Cr was found in the Cr(VI) valence state. There was no statistical difference between the smallest and largest mean Cr(VI) to total Cr mass ratio (p-value D 0.19), hence our analysis does not show that particle size affects the contribution of Cr(VI) to total Cr. The predicted total respiratory deposition for the metal particles was ∼25%. The sites of principal deposition were the head airways (7–10%) and the alveolar region (11–14%). Estimated Cr(VI) deposition was highest in the alveolar region (14%). PMID:26848207

  5. Size Distribution and Estimated Respiratory Deposition of Total Chromium, Hexavalent Chromium, Manganese, and Nickel in Gas Metal Arc Welding Fume Aerosols.

    PubMed

    Cena, Lorenzo G; Chisholm, William P; Keane, Michael J; Cumpston, Amy; Chen, Bean T

    A laboratory study was conducted to determine the mass of total Cr, Cr(VI), Mn, and Ni in 15 size fractions for mild and stainless steel gas-metal arc welding (GMAW) fumes. Samples were collected using a nano multi orifice uniform deposition impactor (MOUDI) with polyvinyl chloride filters on each stage. The filters were analyzed by inductively coupled plasma mass spectrometry (ICP-MS) and ion chromatography. Limits of detection (LODs) and quantitation (LOQs) were experimentally calculated and percent recoveries were measured from spiked metals in solution and dry, certified welding-fume reference material. The fraction of Cr(VI) in total Cr was estimated by calculating the ratio of Cr(VI) to total Cr mass for each particle size range. Expected, regional deposition of each metal was estimated according to respiratory-deposition models. The weight percent (standard deviation) of Mn in mild steel fumes was 9.2% (6.8%). For stainless steel fumes, the weight percentages were 8.4% (5.4%) for total Cr, 12.2% (6.5%) for Mn, 2.1% (1.5%) for Ni and 0.5% (0.4%) for Cr(VI). All metals presented a fraction between 0.04 and 0.6 μ m. Total Cr and Ni presented an additional fraction <0.03 μ m. On average 6% of the Cr was found in the Cr(VI) valence state. There was no statistical difference between the smallest and largest mean Cr(VI) to total Cr mass ratio ( p -value D 0.19), hence our analysis does not show that particle size affects the contribution of Cr(VI) to total Cr. The predicted total respiratory deposition for the metal particles was ∼25%. The sites of principal deposition were the head airways (7-10%) and the alveolar region (11-14%). Estimated Cr(VI) deposition was highest in the alveolar region (14%).

  6. A field investigation of a concrete overlay containing silica fume on Route 50 over Opequon Creek.

    DOT National Transportation Integrated Search

    1993-01-01

    This study evaluated concretes containing silica fume for use in overlays as a suitable alternative to the widely used latex-modified concrete (LMC). A two-lane, four-span bridge deck was overlaid with concrete containing silica fume at 7 percent or ...

  7. Contamination Status of Seven Elements in Hooded Cranes Wintering in South-West Kyushu, Japan: Comparison with Red-Crowned Cranes in Hokkaido, Japan.

    PubMed

    Teraoka, Hiroki; Miyagi, Hasumi; Haraguchi, Yuko; Takase, Kozo; Kitazawa, Takio; Noda, Jun

    2018-05-31

    The hooded crane is designated as an endangered species. The cranes breed primarily in wetlands in southeast Russia and China in summer. Most of the hooded crane population winters in the Izumi plain in Japan. It is difficult to know the contamination status of their habitat because of their vast breeding area. We determined the levels of Cd, Pb, As, (total) Hg, Se, Zn, and Cu in the liver, kidney, and muscle of hooded cranes that were found dead in Izumi in the periods 2003-2006 and 2014-2015 compared with the levels in red-crowned cranes in Hokkaido, Japan, as the only cranes in which these elements had been studied extensively. There were no notable differences between levels of the seven elements in the two periods. Overall, tissue levels of the elements examined in hooded cranes were comparable to those in red-crowned cranes except for Hg and Se. Tissue levels of Hg and Se were clearly lower in hooded cranes than in red-crowned cranes that were found dead from 2000. One lead poisoning case was confirmed. The results suggest that Hooded cranes wintering in Izumi are not extensively contaminated with the seven elements examined.

  8. Ozone removal capability of a welding fume respirator containing activated charcoal.

    PubMed

    Johnston, A R; Dyrud, J F; Shih, Y T

    1989-09-01

    Development of air purifying respirators for protection against ozone has been slowed by concerns about oxidation of charcoal and other available sorbents. The suitability of a charcoal sorbent for low concentrations of ozone was evaluated as a part of the development of a half-mask air purifying respirator designed for welding fumes and ozone. Testing of the respirator confirmed that charcoal can be a suitable sorbent for low levels of ozone. Where the respirator is properly selected, fit tested, and worn, respirator use against welding fumes and ozone at concentrations not exceeding 10 times the permissible exposure limit had been recommended.

  9. Tissue distribution of manganese in iron-sufficient or iron-deficient rats after stainless steel welding-fume exposure.

    PubMed

    Park, Jung-Duck; Kim, Ki-Young; Kim, Dong-Won; Choi, Seong-Jin; Choi, Byung-Sun; Chung, Yong Hyun; Han, Jeong Hee; Sung, Jae Hyuck; Kwon, Il Hoon; Mun, Je-Hyeok; Yu, Il Je

    2007-05-01

    Welders can be exposed to high levels of manganese through welding fumes. Although it has already been suggested that excessive manganese exposure causes neurotoxicity, called manganism, the pathway of manganese transport to the brain with welding-fume exposure remains unclear. Iron is an essential metal that maintains a homeostasis in the body. The divalent metal transporter 1 (DMT1) transports iron and other divalent metals, such as manganese, and the depletion of iron is known to upregulate DMT1 expression. Accordingly, this study investigated the tissue distribution of manganese in iron-sufficient and iron-deficient rats after welding-fume exposure. The feeding of an iron-deficient diet for 4 wk produced a depletion of body iron, such as decreased iron levels in the serum and tissues, and upregulated the DMT1 expression in the rat duodenum. The iron-sufficient and iron-deficient rats were then exposed to welding fumes generated from manual metal arc stainless steel at a concentration of 63.5 +/- 2.3 mg/m3 for 2 h per day over a 30-day period. Animals were sacrificed on days 1, 15, and 30. The level of body iron in the iron-deficient rats was restored to the control level after the welding-fume exposure. However, the tissue distributions of manganese after the welding-fume exposure showed similar patterns in both the iron-sufficient and iron-deficient groups. The concentration of manganese increased in the lungs and liver on days 15 and 30, and increased in the olfactory bulb on day 30. Slight and heterogeneous increases of manganese were observed in different brain regions. Consequently, these findings suggest that the presence of Fe in the inhaled welding fumes may not have a significant effect on the uptake of Mn into the brain. Thus, the condition of iron deficiency did not seem to have any apparent effect on the transport of Mn into the brain after the inhalation of welding fumes.

  10. Effectiveness of two nitrous oxide scavenging nasal hoods during routine pediatric dental treatment.

    PubMed

    Chrysikopoulou, Aikaterini; Matheson, Pamela; Milles, Maano; Shey, Zia; Houpt, Milton

    2006-01-01

    This study compared the effectiveness of 2 nasal hoods (Porter/Brown and Accutron) in reducing waste nitrous oxide gas during conscious sedation for routine pediatric dental treatment. Thirty children, ages 3 to 8 years (mean=5.4 +/- 1.2 years), participated in this study. Fifteen randomly selected children started with the Porter/Brown mask, which was then switched to the Accutron mask, and the other 15 children used the reverse order of masks. Four measurements of ambient nitrous oxide were recorded with a Miran 205B Portable Ambient Air Analyzer 5 minutes after each of the following: (1) administration of nitrous oxide; (2) placement of the rubber dam; (3) change of the nasal hood; and (4) reduction of the vacuum. Samples were taken 8 inches above the nose of the patient and in the room 5 feet away from the patient. Nitrous oxide levels were significantly lower (P<.05) with the Porter/Brown system (31 +/- 40 ppm for the patient and 8 +/- 10 ppm for the room) compared with the Accutron system (375 +/- 94 ppm for the patient and 101 +/- 37 ppm for the room). When the suction was reduced, there was an increase in nitrous oxide levels with the Porter/Brown nasal hood (169 +/- 112 ppm for the patient and 28 +/- 18 ppm for the room), whereas the levels with the Accutron nasal hood remained high (368 +/- 107 ppm for the patient and 121 +/- 50 ppm for the room). This study demonstrated that removal of waste nitrous oxide was greater with the Porter/Brown device and that recommended suction levels must be used for optimum effectiveness.

  11. Recent eruptive history of Mount Hood, Oregon, and potential hazards from future eruptions

    USGS Publications Warehouse

    Crandell, Dwight Raymond

    1980-01-01

    Each of three major eruptive periods at Mount Hood (12,000-15,000(?), 1,500-1,800, and 200-300 years ago) produced dacite domes, pyroclastic flows, and mudflows, but virtually no pumice. Most of the fine lithic ash that mantles the slopes of the volcano and the adjacent mountains fell from ash clouds that accompanied the pyroclastic flows. Widely scattered pumice lapilli that are present at the ground surface on the south, east, and north sides of Mount Hood may have been erupted during the mid-1800's, when the last known activity of the volcano occurred. The geologically recent history of Mount Hood suggests that the most likely eruptive event in the future will be the formation of another dome, probably within the present south-facing crater. The principal hazards that could accompany dome formation include pyroclastic flows and mudflows moving from the upper slopes of the volcano down the floors of valleys. Ash clouds which accompany pyroclastic flows may deposit as much as a meter of fine ash close to their source, and as much as 20 centimeters at a distance of 11 kilometers downwind from the pyroclastic flows. Other hazards that could result from such eruptions include laterally directed explosive blasts that could propel rock fragments outward from the sides of a dome at high speed, and toxic volcanic gases. The scarcity of pumiceous ash erupted during the last 15,000 years suggests that explosive pumice eruptions are not a major hazard at Mount Hood; thus, there seems to be little danger that such an eruption will significantly affect the Portland (Oregon) metropolitan area in the near future.

  12. Mass transfer inside a flux hood for the sampling of gaseous emissions from liquid surfaces - Experimental assessment and emission rate rescaling

    NASA Astrophysics Data System (ADS)

    Prata, Ademir A.; Lucernoni, Federico; Santos, Jane M.; Capelli, Laura; Sironi, Selena; Le-Minh, Nhat; Stuetz, Richard M.

    2018-04-01

    This study assesses the mass transfer of compounds inside the US EPA flux hood, one of the enclosure devices most commonly employed for the direct measurement of atmospheric emissions from liquid surfaces in wastewater treatment plants (WWTPs). Experiments comprised the evaporation of water and the volatilisation of a range of volatile organic compounds (VOCs). Special attention was given to the evaluation of the mass transfer coefficients in the microenvironment created by the flux hood and the effects of concentration build up in the hood's headspace. The VOCs emission rates and the water evaporation rates generally increased with the sweep air flow rate, as did the mass transfer coefficients for all compounds. The emission of compounds whose volatilisation is significantly influenced by the gas phase was greatly affected by concentration build up, whereas this effect was not significant for liquid phase-controlled compounds. The gas-film mass transfer coefficient (kG) estimated inside the US EPA flux hood was of the same order as the respective kG reported in the literature for wind tunnel-type devices, but the emission rates measured by the flux hood can be expected to be lower, due to the concentration build-up. Compared against an emission model for the passive surfaces in WWTPs, the mass transfer of acetic acid (representing a gas phase-dominated compound) inside the US EPA flux hood was equivalent to conditions of wind speeds at 10 m height (U10) of 0.27, 0.51 and 0.99 m s-1, respectively, for sweep air flow rates of 2, 5 and 10 L min-1. On the other hand, for higher wind speeds, the emission rates of gas phase-controlled compounds obtained with the flux hood can be considerably underestimated: for instance, at U10 = 5 m s-1, the emission rates of acetic acid inside the flux hood would be approximately 23, 12 and 6 times lower than the emission rates in the field, for sweep air flow rates of 2, 5 and 10 L min-1, respectively. A procedure is presented in

  13. 40 CFR Appendix G to Part 50 - Reference Method for the Determination of Lead in Suspended Particulate Matter Collected From...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... obtains filters with a lead content of 75 µg/filter. It is important that the variation in lead content... important to keep the sample covered so that corrosion products—formed on fume hood surfaces which may... National Science Foundation for publications, 1976. 3. Zdrojewski, A. et al. “The Accurate Measurement of...

  14. 40 CFR Appendix G to Part 50 - Reference Method for the Determination of Lead in Suspended Particulate Matter Collected From...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... obtains filters with a lead content of 75 µg/filter. It is important that the variation in lead content... important to keep the sample covered so that corrosion products—formed on fume hood surfaces which may... National Science Foundation for publications, 1976. 3. Zdrojewski, A. et al. “The Accurate Measurement of...

  15. 40 CFR Appendix G to Part 50 - Reference Method for the Determination of Lead in Suspended Particulate Matter Collected From...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... obtains filters with a lead content of 75 µg/filter. It is important that the variation in lead content... important to keep the sample covered so that corrosion products—formed on fume hood surfaces which may... National Science Foundation for publications, 1976. 3. Zdrojewski, A. et al. “The Accurate Measurement of...

  16. Improving Understanding of the Fate and Transport of Munitions Constituents to Enhance Sustainability of Operational Ranges

    DTIC Science & Technology

    2015-05-01

    with a 0.45 µm Millipore Durapore PVDF (polyvinylidene fluoride) filter (13 mm diam.) in a Luer filter holder attached to a stainless steel Luer...were recorded. All extractions were performed in a fume hood. DI water (5 mL) was added to each of the test tubes containing supernatant and the new

  17. Characterization of Metal-Insulator-Transition (MIT) Phase Change Materials (PCM) for Reconfigurable Components, Circuits, and Systems

    DTIC Science & Technology

    2013-03-01

    materials have been introduced as dopants: Vanadium (V), Chromium (Cr), Manganese (Mn), Lead (Pb), and Iron (Fe) [41, 42, 43, 44]. While these...value reported in literature, 188°C, due to the samples being heated on an open air hot plate in a laminar flow fume hood. The average resistivity of

  18. Enhancing the performance of green solid-state electric double-layer capacitor incorporated with fumed silica nanoparticles

    NASA Astrophysics Data System (ADS)

    Chong, Mee Yoke; Numan, Arshid; Liew, Chiam-Wen; Ng, H. M.; Ramesh, K.; Ramesh, S.

    2018-06-01

    Solid polymer electrolyte (SPE) based on fumed silica nanoparticles as nanofillers, hydroxylethyl cellulose (HEC) as host polymer, magnesium trifluoromethanesulfonate salt and 1-ethyl-3-methylimidazolium trifluoromethanesulfonate ionic liquid is prepared by solution casting technique. The ionic conductivity, interactions of adsorbed ions on the host polymer, structural crystallinity and thermal stability are evaluated by electrochemical impedance spectroscopy (EIS), Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD) and thermogravimetric analysis (TGA), respectively. Ionic conductivity studies at room temperature reveals that the SPE with 2 wt. % of fumed silica nanoparticles gives the highest conductivity compared to its counterpart. The XRD and FTIR studies confirm the dissolution of salt, ionic liquid and successful incorporation of fumed silica nanoparticles with host polymer. In order to examine the performance of SPEs, electric double-layer capacitor (EDLC) are fabricated by using activated carbon electrodes. EDLC studies demonstrate that SPE incorporated with 2 wt. % fumed silica nanoparticles gives high specific capacitance (25.0 F/g) at a scan rate of 5 mV/s compared to SPE without fumed silica. Additionally, it is able to withstand 71.3% of capacitance from its initial capacitance value over 1600 cycles at a current density of 0.4 A/g.

  19. Removing volatile organic compounds in cooking fume by nano-sized TiO2 photocatalytic reaction combined with ozone oxidation technique.

    PubMed

    Li, Yu-Hua; Cheng, Su-Wen; Yuan, Chung-Shin; Lai, Tzu-Fan; Hung, Chung-Hsuang

    2018-06-05

    Chinese cooking fume is one of the sources of volatile organic compounds (VOCs) in the air. An innovative control technology combining photocatalytic degradation and ozone oxidation (UV/TiO 2 +O 3 ) was developed to decompose VOCs in the cooking fume. Fiberglass filter (FGF) coated with TiO 2 was prepared by an impregnation procedure. A continuous-flow reaction system was self-designed by combining photocatalysis with advanced ozone oxidation technique. By passing the simulated cooking fume through the FGF, the VOC decomposition efficiency in the cooking fume could be increased by about 10%. The decomposition efficiency of VOCs in the cooking fume increased and then decreased with the inlet VOC concentration. A maximum VOC decomposition efficiency of 64% was obtained at 100 ppm. Similar trend was observed for reaction temperature with the VOC decomposition efficiencies ranging from 64 to 68%. Moreover, inlet ozone concentration had a positive effect on the decomposition of VOCs in the cooking fume for inlet ozone≤1000 ppm and leveled off for inlet ozone>1000 ppm. 34% of VOC decomposition efficiency was achieved solely by ozone oxidation with or without near-UV irradiation. A maximum of 75% and 94% VOC decomposition efficiency could be achieved by O 3 +UV/TiO 2 and UV/TiO 2 +O 3 techniques, respectively. The maximum decomposition efficiencies of VOCs decreased to 79% for using UV/TiO 2 +O 3 technique with adding water in the oil fume. Comparing the chromatographical species of VOCs in the oil fume before and after the decomposition of VOCs by using UV/TiO 2 +O 3 technique, we found that both TVOC and VOC species in the oil fume were effectively decomposed. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. 42 CFR 84.1141 - Isoamyl acetate tightness test; dust, fume, and mist respirators designed for respiratory...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist... 42 Public Health 1 2013-10-01 2013-10-01 false Isoamyl acetate tightness test; dust, fume, and...

  1. 42 CFR 84.1141 - Isoamyl acetate tightness test; dust, fume, and mist respirators designed for respiratory...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist... 42 Public Health 1 2010-10-01 2010-10-01 false Isoamyl acetate tightness test; dust, fume, and...

  2. 42 CFR 84.1141 - Isoamyl acetate tightness test; dust, fume, and mist respirators designed for respiratory...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist... 42 Public Health 1 2014-10-01 2014-10-01 false Isoamyl acetate tightness test; dust, fume, and...

  3. 42 CFR 84.1141 - Isoamyl acetate tightness test; dust, fume, and mist respirators designed for respiratory...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist... 42 Public Health 1 2012-10-01 2012-10-01 false Isoamyl acetate tightness test; dust, fume, and...

  4. 42 CFR 84.1141 - Isoamyl acetate tightness test; dust, fume, and mist respirators designed for respiratory...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist... 42 Public Health 1 2011-10-01 2011-10-01 false Isoamyl acetate tightness test; dust, fume, and...

  5. Investigation of silica fume concrete bridge deck overlay failures.

    DOT National Transportation Integrated Search

    2016-02-23

    Many of these microsilica-modified concrete or silica fume concrete (SFC) bridge deck overlays across the State of Wyoming are suffering from premature distress that includes random cracking, loss of bond and delaminations. To determine the most like...

  6. Two-dimensional time-dependent modelling of fume formation in a pulsed gas metal arc welding process

    NASA Astrophysics Data System (ADS)

    Boselli, M.; Colombo, V.; Ghedini, E.; Gherardi, M.; Sanibondi, P.

    2013-06-01

    Fume formation in a pulsed gas metal arc welding (GMAW) process is investigated by coupling a time-dependent axi-symmetric two-dimensional model, which takes into account both droplet detachment and production of metal vapour, with a model for fume formation and transport based on the method of moments for the solution of the aerosol general dynamic equation. We report simulative results of a pulsed process (peak current = 350 A, background current 30 A, period = 9 ms) for a 1 mm diameter iron wire, with Ar shielding gas. Results showed that metal vapour production occurs mainly at the wire tip, whereas fume formation is concentrated in the fringes of the arc in the spatial region close to the workpiece, where metal vapours are transported by convection. The proposed modelling approach allows time-dependent tracking of fumes also in plasma processes where temperature-time variations occur faster than nanoparticle transport from the nucleation region to the surrounding atmosphere, as is the case for most pulsed GMAW processes.

  7. Mt. Hood Community College Institutional Effectiveness (IE) Report Fall 2001.

    ERIC Educational Resources Information Center

    Walleri, R. Dan

    This report examines the indicators of institutional effectiveness for Mount Hood Community College (MHCC) (Oregon). The document reports on five institutional goals: (1) knowledge-based workforce education and services; (2) access for members of the community and development of an environment in which diversity thrives; (3) economic development,…

  8. Suppression in lung defense responses after bacterial infection in rats pretreated with different welding fumes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Antonini, James M.; Taylor, Michael D.; Millecchia, Lyndell

    2004-11-01

    Epidemiology suggests that inhalation of welding fumes increases the susceptibility to lung infection. The effects of chemically distinct welding fumes on lung defense responses after bacterial infection were compared. Fume was collected during gas metal arc (GMA) or flux-covered manual metal arc (MMA) welding using two consumable electrodes: stainless steel (SS) or mild steel (MS). The fumes were separated into water-soluble and -insoluble fractions. The GMA-SS and GMA-MS fumes were found to be relatively insoluble, whereas the MMA-SS was highly water soluble, with the soluble fraction comprised of 87% Cr and 11% Mn. On day 0, male Sprague-Dawley rats weremore » intratracheally instilled with saline (vehicle control) or the different welding fumes (0.1 or 2 mg/rat). At day 3, the rats were intratracheally inoculated with 5 x 10{sup 3} Listeria monocytogenes. On days 6, 8, and 10, left lungs were removed, homogenized, cultured overnight, and colony-forming units were counted to assess pulmonary bacterial clearance. Bronchoalveolar lavage (BAL) was performed on right lungs to recover phagocytes and BAL fluid to measure the production of nitric oxide (NO) and immunomodulatory cytokines, including tumor necrosis factor-{alpha} (TNF-{alpha}), interleukin (IL)-2, IL-6, and IL-10. In contrast to the GMA-SS, GMA-MS, and saline groups, pretreatment with the highly water soluble MMA-SS fume caused significant body weight loss, extensive lung damage, and a dramatic reduction in pulmonary clearance of L. monocytogenes after infection. NO concentrations in BAL fluid and lung immunostaining of inducible NO synthase were dramatically increased in rats pretreated with MMA-SS before and after infection. MMA-SS treatment caused a significant decrease in IL-2 and significant increases in TNF-{alpha}, IL-6, and IL-10 after infection. In conclusion, pretreatment with MMA-SS increased production of NO and proinflammatory cytokines (TNF-{alpha} and IL-6) after infection, which are

  9. Suppression in lung defense responses after bacterial infection in rats pretreated with different welding fumes.

    PubMed

    Antonini, James M; Taylor, Michael D; Millecchia, Lyndell; Bebout, Alicia R; Roberts, Jenny R

    2004-11-01

    Epidemiology suggests that inhalation of welding fumes increases the susceptibility to lung infection. The effects of chemically distinct welding fumes on lung defense responses after bacterial infection were compared. Fume was collected during gas metal arc (GMA) or flux-covered manual metal arc (MMA) welding using two consumable electrodes: stainless steel (SS) or mild steel (MS). The fumes were separated into water-soluble and -insoluble fractions. The GMA-SS and GMA-MS fumes were found to be relatively insoluble, whereas the MMA-SS was highly water soluble, with the soluble fraction comprised of 87% Cr and 11% Mn. On day 0, male Sprague-Dawley rats were intratracheally instilled with saline (vehicle control) or the different welding fumes (0.1 or 2 mg/rat). At day 3, the rats were intratracheally inoculated with 5 x 10(3) Listeria monocytogenes. On days 6, 8, and 10, left lungs were removed, homogenized, cultured overnight, and colony-forming units were counted to assess pulmonary bacterial clearance. Bronchoalveolar lavage (BAL) was performed on right lungs to recover phagocytes and BAL fluid to measure the production of nitric oxide (NO) and immunomodulatory cytokines, including tumor necrosis factor-alpha (TNF-alpha), interleukin (IL)-2, IL-6, and IL-10. In contrast to the GMA-SS, GMA-MS, and saline groups, pretreatment with the highly water soluble MMA-SS fume caused significant body weight loss, extensive lung damage, and a dramatic reduction in pulmonary clearance of L. monocytogenes after infection. NO concentrations in BAL fluid and lung immunostaining of inducible NO synthase were dramatically increased in rats pretreated with MMA-SS before and after infection. MMA-SS treatment caused a significant decrease in IL-2 and significant increases in TNF-alpha, IL-6, and IL-10 after infection. In conclusion, pretreatment with MMA-SS increased production of NO and proinflammatory cytokines (TNF-alpha and IL-6) after infection, which are likely responsible for

  10. Assessment of Occupational Exposure to Manganese and Other Metals in Welding Fumes by Portable X-ray Fluorescence Spectrometer

    PubMed Central

    Laohaudomchok, Wisanti; Cavallari, Jennifer M.; Fang, Shona C.; Lin, Xihong; Herrick, Robert F.; Christiani, David C.; Weisskopf, Marc G.

    2011-01-01

    Elemental analysis of welding fume samples can be done using several laboratory-based techniques. However, portable measurement techniques could offer several advantages. In this study, we sought to determine whether the portable X-ray fluorescence spectrometer (XRF) is suitable for analysis of five metals (manganese, iron, zinc, copper, and chromium) on 37-mm polytetrafluoroethylene filters. Using this filter fitted on a cyclone in line with a personal pump, gravimetric samples were collected from a group of boilermakers exposed to welding fumes. We assessed the assumption of uniform deposition of these metals on the filters, and the relationships between measurement results of each metal obtained from traditional laboratory-based XRF and the portable XRF. For all five metals of interest, repeated measurements with the portable XRF at the same filter area showed good consistency (reliability ratios are equal or close to 1.0 for almost all metals). The portable XRF readings taken from three different areas of each filter were not significantly different (p-values = 0.77 to 0.98). This suggested that the metal rich PM2.5 deposits uniformly on the samples collected using this gravimetric method. For comparison of the two XRFs, the results from the portable XRF were well correlated and highly predictive of those from the laboratory XRF. The Spearman correlation coefficients were from 0.325 for chromium, to 0.995 for manganese and 0.998 for iron. The mean differences as a percent of the mean laboratory XRF readings were also small (<5%) for manganese, iron, and copper. The differences were greater for zinc and chromium, which were present at very low amounts in our samples and below the limits of detection of the portable XRF for many of the samples. These five metals were moderately to strongly correlated with the total fine particle fraction on filters (Spearman ρ = 0.41 for zinc to 0.97 for iron). Such strong correlations and comparable results suggested that the

  11. Assessment of occupational exposure to manganese and other metals in welding fumes by portable X-ray fluorescence spectrometer.

    PubMed

    Laohaudomchok, Wisanti; Cavallari, Jennifer M; Fang, Shona C; Lin, Xihong; Herrick, Robert F; Christiani, David C; Weisskopf, Marc G

    2010-08-01

    Elemental analysis of welding fume samples can be done using several laboratory-based techniques. However, portable measurement techniques could offer several advantages. In this study, we sought to determine whether the portable X-ray fluorescence spectrometer (XRF) is suitable for analysis of five metals (manganese, iron, zinc, copper, and chromium) on 37-mm polytetrafluoroethylene filters. Using this filter fitted on a cyclone in line with a personal pump, gravimetric samples were collected from a group of boilermakers exposed to welding fumes. We assessed the assumption of uniform deposition of these metals on the filters, and the relationships between measurement results of each metal obtained from traditional laboratory-based XRF and the portable XRF. For all five metals of interest, repeated measurements with the portable XRF at the same filter area showed good consistency (reliability ratios are equal or close to 1.0 for almost all metals). The portable XRF readings taken from three different areas of each filter were not significantly different (p-values = 0.77 to 0.98). This suggested that the metal rich PM(2.5) deposits uniformly on the samples collected using this gravimetric method. For comparison of the two XRFs, the results from the portable XRF were well correlated and highly predictive of those from the laboratory XRF. The Spearman correlation coefficients were from 0.325 for chromium, to 0.995 for manganese and 0.998 for iron. The mean differences as a percent of the mean laboratory XRF readings were also small (<5%) for manganese, iron, and copper. The differences were greater for zinc and chromium, which were present at very low amounts in our samples and below the limits of detection of the portable XRF for many of the samples. These five metals were moderately to strongly correlated with the total fine particle fraction on filters (Spearman rho = 0.41 for zinc to 0.97 for iron). Such strong correlations and comparable results suggested that

  12. Effectiveness of catch basins equipped with hoods in retaining gross solids and hydrocarbons in highway runoff, Southeast Expressway, Boston, Massachusetts, 2008-09

    USGS Publications Warehouse

    Smith, Kirk P.

    2011-01-01

    Stormwater mobilizes litter and other debris along the roadway where it is transported to the highway drainage systems. Initial treatment for stormwater runoff typically is provided by catch basins in highway settings. Modification of catch basins to include hoods that cover the catch-basin outlet is intended to enhance catch-basin performance by retaining floatable debris and various hydrophobic organic compounds that tend to float on the water surface within the sump of the catch basin. The effectiveness of six deep-sump off-line catch basins equipped with hoods in reducing the mass of gross solids greater than 0.25 inches in diameter and concentrations of oil and grease (OG) and total petroleum hydrocarbons (TPH) was examined along the Southeast Expressway, in Boston, Massachusetts. Two deep-sump catch basins were equipped with cast-iron hoods. Three were equipped with molded plastic hoods, known as an Eliminator, and a single catch basin was equipped with a fiberglass anti-siphoning hood, known as a Snout. Samples of gross solids greater than 0.25 inches in diameter, excluding gravel and metallic materials, were routinely collected for a 6-month period from a collection structure mounted at the end of each catch-basin outlet pipe. After about 6 months, all floatable, saturated low-density and high-density solids were removed from each catch basin. In addition to the collection of samples of gross solids, samples of sump water from five catch basins and flow-weighted composite samples of stormwater from the outlet of one catch basin were collected and analyzed for concentrations of OG and TPH. A mass balance approach was used to assess the effectiveness of each catch basin equipped with a hood in retaining gross solids. The effectiveness of the deep-sump catch basins fitted with one of three types of hoods in retaining gross solids ranged from 27 to 52 percent. From 45 to 90 percent of the gross solids collected from the catch-basin sumps were composed of

  13. Inhalation exposure of rats to asphalt fumes generated at paving temperatures alters pulmonary xenobiotic metabolism pathways without lung injury.

    PubMed Central

    Ma, Jane Y C; Rengasamy, Apavoo; Frazer, Dave; Barger, Mark W; Hubbs, Ann F; Battelli, Lori; Tomblyn, Seith; Stone, Samuel; Castranova, Vince

    2003-01-01

    Asphalt fumes are complex mixtures of various organic compounds, including polycyclic aromatic hydrocarbons (PAHs). PAHs require bioactivation by the cytochrome P-450 monooxygenase system to exert toxic/carcinogenic effects. The present study was carried out to characterize the acute pulmonary inflammatory responses and the alterations of pulmonary xenobiotic pathways in rats exposed to asphalt fumes by inhalation. Rats were exposed at various doses and time periods to air or to asphalt fumes generated at paving temperatures. To assess the acute damage and inflammatory responses, differential cell counts, acellular lactate dehydrogenase (LDH) activity, and protein content of bronchoalveolar lavage fluid were determined. Alveolar macrophage (AM) function was assessed by monitoring generation of chemiluminescence and production of tumor necrosis factor-alpha and interleukin-1. Alteration of pulmonary xenobiotic pathways was determined by monitoring the protein levels and activities of P-450 isozymes (CYP1A1 and CYP2B1), glutathioneS-transferase (GST), and NADPH:quinone oxidoreductase (QR). The results show that acute asphalt fume exposure did not cause neutrophil infiltration, alter LDH activity or protein content, or affect AM function, suggesting that short-term asphalt fume exposure did not induce acute lung damage or inflammation. However, acute asphalt fume exposure significantly increased the activity and protein level of CYP1A1 whereas it markedly reduced the activity and protein level of CYP2B1 in the lung. The induction of CYP1A1 was localized in nonciliated bronchiolar epithelial (Clara) cells, alveolar septa, and endothelial cells by immunofluorescence microscopy. Cytosolic QR activity was significantly elevated after asphalt fume exposure, whereas GST activity was not affected by the exposure. This induction of CYP1A1 and QR with the concomitant down-regulation of CYP2B1 after asphalt fume exposure could alter PAH metabolism and may lead to potential

  14. Black on Black Crime: Hollywood's Construction of the Hood.

    ERIC Educational Resources Information Center

    Pierson, Eric

    Most of what the world envisions of the period of westward expansion in America has been crafted through Hollywood cinema. The myths of the West are so ingrained in America's culture that they have taken on a truth all their own. In a series of recent films, which began with the release of "Boyz N the Hood," Hollywood is at it again, presenting…

  15. People and Policy Strategies | Climate Neutral Research Campuses | NREL

    Science.gov Websites

    People and Policy Strategies People and Policy Strategies Strategies that impact human behavior and Work Strategies Land Use Space Management Space Planning and Use Energy conservation policies encourage building occupants to turn off lights and computers, close fume hoods, limit appliance use in offices, and

  16. Soxhlet Extraction of Caffeine from Beverage Plants

    NASA Astrophysics Data System (ADS)

    Adam, D. J.; Mainwaring, J.; Quigley, Michael N.

    1996-12-01

    A simple procedure is described for the extraction of caffeine from coffee beans or granules, tea leaves, mat leaves, etc. Since dichloromethane and several other hazardous substances are used, the procedure is best performed in a fume hood. Following extraction, melting point determination of the crystalline precipitate establishes its positive identity. Includes 33 references.

  17. 33 CFR 334.1220 - Hood Canal, Bangor; naval restricted areas.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 3 2012-07-01 2012-07-01 false Hood Canal, Bangor; naval restricted areas. 334.1220 Section 334.1220 Navigation and Navigable Waters CORPS OF ENGINEERS, DEPARTMENT OF... intermittently by the Navy for magnetic silencing operations. (B) Use of any equipment such as anchors, grapnels...

  18. Exposure to welding fumes activates DNA damage response and redox-sensitive transcription factor signalling in Sprague-Dawley rats.

    PubMed

    Krishnaraj, Jayaraman; Kowshik, Jaganathan; Sebastian, Robin; Raghavan, Sathees C; Nagini, Siddavaram

    2017-05-15

    Occupational exposure to welding fumes containing a complex mixture of genotoxic heavy metals, radiation, gases and nanoparticles poses a serious health hazard to welders. Since their categorization as possible carcinogens, welding fumes have gained increasing attention as high priority agents for risk assessment. The present study was undertaken to investigate the effects of welding fume inhalation on oxidative stress, DNA damage response (DDR), and nuclear factor erythroid 2-related factor-2 (Nrf2) and nuclear factor kappa B (NFκB) signalling in the lung tissues of male Sprague-Dawley rats . METHODS: Animals were divided into five groups. Group 1 animals served as control. Rats in groups 2-5 were exposed to 50mg/m 3 stainless steel (SS) welding fumes for 1h for 1day, 1 week, 2 weeks, and 4 weeks respectively. Reactive oxygen species (ROS) generation, 8-oxo-2'-deoxyguanosine (8-oxodG), xenobiotic-metabolizing enzymes (XMEs) and antioxidants were analysed. DNA damage sensors, DNA repair enzymes, inflammatory mediators, cell cycle progression, apoptosis and key players in Nrf2 and NFκB signalling were assessed by flow cytometry, quantitative real-time reverse transcriptase PCR, immunoblotting, immunohistochemistry and immunofluorescence. Rats exposed to welding fumes showed increased levels of chromium and ROS in lung tissues associated with accumulation of 8-oxodG and enhanced expression of XMEs and antioxidants. This was accompanied by upregulation of DNA damage sensors, cell cycle arrest in G1/S phase, overexpression of a multitude of DNA repair enzymes and caspase-mediated apoptosis. In addition, exposure to welding fumes induced activation of Nrf2 and NFκB signalling with enhanced expression of inflammatory mediators. The results of the present study unequivocally demonstrate that exposure of rats to SS welding fumes alters the expression of 37 genes involved in oxidative stress, detoxification, inflammation, DNA repair, cell cycle progression, and apoptosis

  19. Total fume and metal concentrations during welding in selected factories in Jeddah, Saudi Arabia.

    PubMed

    Balkhyour, Mansour Ahmed; Goknil, Mohammad Khalid

    2010-07-01

    Welding is a major industrial process used for joining metals. Occupational exposure to welding fumes is a serious occupational health problem all over the world. The degree of risk to welder's health from fumes depends on composition, concentration, and the length of exposure. The aim of this study was to investigate workers' welding fume exposure levels in some industries in Jeddah, Saudi Arabia. In each factory, the air in the breathing zone within 0.5 m from welders was sampled during 8-hour shifts. Total particulates, manganese, copper, and molybdenum concentrations of welding fumes were determined. Mean values of eight-hour average particulate concentrations measured during welding at the welders breathing zone were 6.3 mg/m(3) (Factory 1), 5.3 mg/m(3) (Factory 2), 11.3 mg/m(3) (Factory 3), 6.8 mg/m(3) (Factory 4), 4.7 mg/m(3) (Factory 5), and 3.0 mg/m(3) (Factory 6). Mean values of airborne manganese, copper, and molybdenum levels measured during welding were in the range of 0.010 mg/m(3)-0.477 mg/m(3), 0.001 mg/m(3)-0.080 mg/m(3) and 0.001 mg/m(3)-0.058 mg/m(3) respectively. Mean values of calculated equivalent exposure values were: 1.50 (Factory 1), 1.56 (Factory 2), 5.14 (Factory 3), 2.21 (Factory 4), 2.89 (Factory 5), and 1.20 (Factory 6). The welders in factories 1, 2, 3, and 4 were exposed to welding fume concentration above the SASO limit value, which may increase the risk of respiratory health problems.

  20. Effects of pulmonary exposure to chemically-distinct welding fumes on neuroendocrine markers of toxicity.

    PubMed

    Krajnak, K; Sriram, K; Johnson, C; Roberts, J R; Mercer, R; Miller, G R; Wirth, O; Antonini, J M

    2017-01-01

    Exposure to welding fumes may result in disorders of the pulmonary, cardiovascular, and reproductive systems. Welders are also at a greater risk of developing symptoms similar to those seen in individuals with idiopathic Parkinson's disease. In welders, there are studies that suggest that alterations in circulating prolactin concentrations may be indicative of injury to the dopamine (DA) neurons in the substantia nigra. The goal of these studies was to use an established model of welding particulate exposure to mimic the effects of welding fume inhalation on reproductive functions. Since previous investigators suggested that changes in circulating prolactin may be an early marker of DA neuron injury, movement disorders, and reproductive dysfunction, prolactin, hypothalamic tyrosine hydroxylase (TH) levels (a marker of DA synthesis), and other measures of hypothalamic-pituitary-gonadal (HPG) function were measured after repetitive instillation of welding fume particulates generated by flux core arc-hard surfacing (FCA-HS), manual metal arc-hard surfacing (MMA-HS) or gas metal arc-mild steel (GMA-MS) welding, or manganese chloride (MnCl 2 ). Exposure to welding fume particulate resulted in the accumulation of various metals in the pituitary and testes of rats, along with changes in hypothalamic TH and serum prolactin levels. Exposure to particulates with high concentrations of soluble manganese (Mn) appeared to exert the greatest influence on TH activity levels and serum prolactin concentrations. Thus, circulating prolactin levels may serve as a biomarker for welding fume/Mn-induced neurotoxicity. Other reproductive measures were collected, and these data were consistent with epidemiological findings that prolactin and testosterone may serve as biomarkers of welding particulate induced DA neuron and reproductive dysfunction.

  1. ALTERATIONS IN CARDIOMYOCYTE FUNCTION AFTER PULMONARY TREATMENT WITH STAINLESS STEEL WELDING FUME IN RATS

    PubMed Central

    Popstojanov, Risto; Antonini, James M.; Salmen, Rebecca; Ye, Morgan; Zheng, Wen; Castranova, Vincent; Fekedulegn, Desta B.; Kan, Hong

    2015-01-01

    Welding fume is composed of a complex of different metal particulates. Pulmonary exposure to different welding fumes may exert a negative impact on cardiac function, although the underlying mechanisms remain unclear. To explore the effect of welding fumes on cardiac function, Sprague-Dawley rats were exposed by intratracheal instillation to 2 mg/rat of manual metal arc hard surfacing welding fume (MMA-HS) once per week for 7 wk. Control rats received saline. Cardiomyocytes were isolated enzymatically at d 1 and 7 postexposure. Intracellular calcium ([Ca2+]i) transients (fluorescence ratio) were measured on the stage of an inverted phase-contrast microscope using a myocyte calcium imaging/cell length system. Phosphorylation levels of cardiac troponin I (cTnI) were determined by Western blot. The levels of nonspecific inflammatory marker C-reactive protein (CRP) and proinflammatory cytokine interleukin-6 (IL-6) in serum were measured by enzyme-linked immunosorbent assay (ELISA). Contraction of isolated cardiomyocytes was significantly reduced at d 1 and d 7 postexposure. Intracellular calcium levels were decreased in response to extracellular calcium stimulation at d 7 postexposure. Changes of intracellular calcium levels after isoprenaline hydrochloride (ISO) stimulation were not markedly different between groups at either time point. Phosphorylation levels of cTnI in the left ventricle were significantly lower at d 1 post-exposure. The serum levels of CRP were not markedly different between groups at either time point. Serum levels of IL-6 were not detectable in both groups. Cardiomyocyte alterations observed after welding fume treatment were mainly due to alterations in intracellular calcium handling and phosphorylation levels of cTnI. PMID:24786677

  2. Alterations in cardiomyocyte function after pulmonary treatment with stainless steel welding fume in rats.

    PubMed

    Popstojanov, Risto; Antonini, James M; Salmen, Rebecca; Ye, Morgan; Zheng, Wen; Castranova, Vincent; Fekedulegn, Desta B; Kan, Hong

    2014-01-01

    Welding fume is composed of a complex of different metal particulates. Pulmonary exposure to different welding fumes may exert a negative impact on cardiac function, although the underlying mechanisms remain unclear. To explore the effect of welding fumes on cardiac function, Sprague-Dawley rats were exposed by intratracheal instillation to 2 mg/rat of manual metal arc hard surfacing welding fume (MMA-HS) once per week for 7 wk. Control rats received saline. Cardiomyocytes were isolated enzymatically at d 1 and 7 postexposure. Intracellular calcium ([Ca(2+)]i) transients (fluorescence ratio) were measured on the stage of an inverted phase-contrast microscope using a myocyte calcium imaging/cell length system. Phosphorylation levels of cardiac troponin I (cTnI) were determined by Western blot. The levels of nonspecific inflammatory marker C-reactive protein (CRP) and proinflammatory cytokine interleukin-6 (IL-6) in serum were measured by enzyme-linked immunosorbent assay (ELISA). Contraction of isolated cardiomyocytes was significantly reduced at d 1 and d 7 postexposure. Intracellular calcium levels were decreased in response to extracellular calcium stimulation at d 7 postexposure. Changes of intracellular calcium levels after isoprenaline hydrochloride (ISO) stimulation were not markedly different between groups at either time point. Phosphorylation levels of cTnI in the left ventricle were significantly lower at d 1 postexposure. The serum levels of CRP were not markedly different between groups at either time point. Serum levels of IL-6 were not detectable in both groups. Cardiomyocyte alterations observed after welding fume treatment were mainly due to alterations in intracellular calcium handling and phosphorylation levels of cTnI.

  3. Evaluation of the amount of nanoparticles emitted in welding fume from stainless steel using different shielding gases.

    PubMed

    Pacheco, R P; Gomes, J F; Miranda, R M; Quintino, M L

    2017-05-01

    The primary objective of this study was to correlate the emission of macro and nanoparticles released during the process of metal inert gas/metal active gas (MIG/MAG) of stainless steel with different gas mixtures. Using different gas mixtures with different heat inputs, it was possible to determine fume formation rates and surface areas of nanoparticles with alveolar lung deposition capacity. It was found, how the various transfer modes and the type of gas protection, in particular, the percentage of active elements in the chemical composition of the gas, affect the amount of fumes generated and also the generation of nanoparticles with a high capacity of deposition. The spray transfer mode always shows higher values of nanoparticles surface area, unlike the fume formation rates. Among the tested mixtures 82%Ar + 18%CO 2 generates higher emissions of nanoparticles as well as fume formation rates.

  4. Reduction of exposure to ultrafine particles by kitchen exhaust hoods: the effects of exhaust flow rates, particle size, and burner position.

    PubMed

    Rim, Donghyun; Wallace, Lance; Nabinger, Steven; Persily, Andrew

    2012-08-15

    Cooking stoves, both gas and electric, are one of the strongest and most common sources of ultrafine particles (UFP) in homes. UFP have been shown to be associated with adverse health effects such as DNA damage and respiratory and cardiovascular diseases. This study investigates the effectiveness of kitchen exhaust hoods in reducing indoor levels of UFP emitted from a gas stove and oven. Measurements in an unoccupied manufactured house monitored size-resolved UFP (2 nm to 100 nm) concentrations from the gas stove and oven while varying range hood flow rate and burner position. The air change rate in the building was measured continuously based on the decay of a tracer gas (sulfur hexafluoride, SF(6)). The results show that range hood flow rate and burner position (front vs. rear) can have strong effects on the reduction of indoor levels of UFP released from the stove and oven, subsequently reducing occupant exposure to UFP. Higher range hood flow rates are generally more effective for UFP reduction, though the reduction varies with particle diameter. The influence of the range hood exhaust is larger for the back burner than for the front burner. The number-weighted particle reductions for range hood flow rates varying between 100 m(3)/h and 680 m(3)/h range from 31% to 94% for the front burner, from 54% to 98% for the back burner, and from 39% to 96% for the oven. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Comparison of pressure drop and filtration efficiency of particulate respirators using welding fumes and sodium chloride.

    PubMed

    Cho, Hyun-Woo; Yoon, Chung-Sik; Lee, Jin-Ho; Lee, Seung-Joo; Viner, Andrew; Johnson, Erik W

    2011-07-01

    Respirators are used to help reduce exposure to a variety of contaminants in workplaces. Test aerosols used for certification of particulate respirators (PRs) include sodium chloride (NaCl), dioctyl phthalate, and paraffin oil. These aerosols are generally assumed to be worst case surrogates for aerosols found in the workplace. No data have been published to date on the performance of PRs with welding fumes, a hazardous aerosol that exists in real workplace settings. The aim of this study was to compare the performance of respirators and filters against a NaCl aerosol and a welding fume aerosol and determine whether or not a correlation between the two could be made. Fifteen commercial PRs and filters (seven filtering facepiece, two replaceable single-type filters, and six replaceable dual-type filters) were chosen for investigation. Four of the filtering facepiece respirators, one of the single-type filters, and all of the dual-type filters contained carbon to help reduce exposure to ozone and other vapors generated during the welding process. For the NaCl test, a modified National Institute for Occupational Safety and Health protocol was adopted for use with the TSI Model 8130 automated filter tester. For the welding fume test, welding fumes from mild steel flux-cored arcs were generated and measured with a SIBATA filter tester (AP-634A, Japan) and a manometer in the upstream and downstream sections of the test chamber. Size distributions of the two aerosols were measured using a scanning mobility particle sizer. Penetration and pressure drop were measured over a period of aerosol loading onto the respirator or filter. Photos and scanning electron microscope images of clean and exposed respirators were taken. The count median diameter (CMD) and mass median diameter (MMD) for the NaCl aerosol were smaller than the welding fumes (CMD: 74 versus 216 nm; MMD: 198 versus 528 nm, respectively). Initial penetration and peak penetration were higher with the NaCl aerosol

  6. Assessment of the biological effects of welding fumes emitted from metal inert gas welding processes of aluminium and zinc-plated materials in humans.

    PubMed

    Hartmann, L; Bauer, M; Bertram, J; Gube, M; Lenz, K; Reisgen, U; Schettgen, T; Kraus, T; Brand, P

    2014-03-01

    The aim of this study was to investigate biological effects and potential health risks due to two different metal-inert-gas (MIG) welding fumes (MIG welding of aluminium and MIG soldering of zinc coated steel) in healthy humans. In a threefold cross-over design study 12 male subjects were exposed to three different exposure scenarios. Exposures were performed under controlled conditions in the Aachener Workplace Simulation Laboratory (AWSL). On three different days the subjects were either exposed to filtered ambient air, to welding fumes from MIG welding of aluminium, or to fumes from MIG soldering of zinc coated materials. Exposure was performed for 6 h and the average fume concentration was 2.5 mg m(-3). Before, directly after, 1 day after, and 7 days after exposure spirometric and impulse oscillometric measurements were performed, exhaled breath condensate (EBC) was collected and blood samples were taken and analyzed for inflammatory markers. During MIG welding of aluminium high ozone concentrations (up to 250 μg m(-3)) were observed, whereas ozone was negligible for MIG soldering. For MIG soldering, concentrations of high-sensitivity CRP (hsCRP) and factor VIII were significantly increased but remained mostly within the normal range. The concentration of neutrophils increased in tendency. For MIG welding of aluminium, the lung function showed significant decreases in Peak Expiratory Flow (PEF) and Mean Expiratory Flow at 75% vital capacity (MEF 75) 7 days after exposure. The concentration of ristocetin cofactor was increased. The observed increase of hsCRP during MIG-soldering can be understood as an indicator for asymptomatic systemic inflammation probably due to zinc (zinc concentration 1.5 mg m(-3)). The change in lung function observed after MIG welding of aluminium may be attributed to ozone inhalation, although the late response (7 days after exposure) is surprising. Copyright © 2013 Elsevier GmbH. All rights reserved.

  7. Geothermal observation wells, Mt. Hood, Oregon. Final report, October 4, 1977-July 9, 1979

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Covert, W.F.; Meyer, H.J.

    1979-11-01

    Exploration drilling operations were conducted which included the deepening of an existing hole, designated as Old Maid Flat No. 1, from 1850 ft (564 m) to 4002 (1220 m) on the western approaches to Mt. Hood and the drilling of three new holes ranging from 940 ft (287 m) to 1340 ft (409 m). The Clear Fork hole, located in Old Maid Flat, was drilled to 1320 ft (402 m). The Zigzag hole was drilled to 940 ft (287 m) at the southwestern base of Mt. Hood in the Zigzag River valley. The remaining hole was drilled on the Timberlinemore » Lodge grounds which is on the south flank of Mt. Hood at an elevation of about 6000 ft (1829 m) above sea level. The deepening project designated as Old Maid Flat No. 1 encountered a maximum bottom hole temperature of about 180/sup 0/F (82/sup 0/C) and is to this date the deepest exploratory hole in the Mt. Hood vicinity. No significant drilling problems were encountered. The Clear Fork and Zigzag River holes were completed without significant problems. The Timberline Lodge hole encountered severe drilling conditions, including unconsolidated formations. Two strings of tools were left in the hole from structural collapse of the hole. The hole was scheduled as a 2000 ft (610 m) test. Drilling did not proceed beyond 1350 ft (412 m) and due to junk it was unobstructed to a depth of 838 ft (255 m). Observation pipe was installed to 735 ft (224 m) due to further disintegration of the hole. The work was prematurely terminated due to weather conditions.« less

  8. Effects of welding fumes of differing composition and solubility on free radical production and acute lung injury and inflammation in rats.

    PubMed

    Taylor, Michael D; Roberts, Jenny R; Leonard, Stephen S; Shi, Xianglin; Antonini, James M

    2003-09-01

    The goals of this study were to examine acute lung damage and inflammation, as well as free radical production, caused by welding fumes of different chemical compositions and solubilities. The fumes were from a gas metal arc welding using a mild-steel (GMA-MS) or stainless-steel electrode (GMA-SS) and a manual metal arc welding using a stainless-steel electrode (MMA-SS), which was further separated into soluble and insoluble fractions. The MMA-SS was the only fume to contain soluble chromium. Free radical production was observed only in suspensions of MMA-SS fume under various conditions. Male Sprague-Dawley rats were intratracheally instilled with either a welding fume suspension at 2 mg/rat or a saline vehicle, and various parameters of inflammation and damage were measured at 3 h and days 1, 3, and 6. Only the MMA-SS treatment caused a continued increase in lung weight until day 6 and elevated lipid peroxidation at day 3. All of the fumes caused increases in macrophages and neutrophils obtained by lavage, but the increased cellularity was extended through day 6 following the MMA-SS treatment only. Only the MMA-SS treatment led to an increased recovery of eosinophils and damage to the alveolar-capillary barrier. While all of the fumes produced increases in cytotoxicity, the MMA-SS treatment caused the maximal response at day 3. These findings indicate that different welding fumes caused varied responses in the lungs of rats, correlated to their metal composition and ability to produce free radicals. Additionally, both the soluble and insoluble fractions of the MMA-SS fume were required to produce most effects, indicating that the responses are not dependent exclusively on the soluble metals.

  9. Archaeological Survey at Fort Hood, Texas Fiscal Years 1991 and 1992: Cantonment and Belton Lake Periphery Areas

    DTIC Science & Technology

    1993-12-01

    is unable to adequately locate rockshelters. Improvement of the elevation data in the Fort Hood GIS would provide better estimates of slope and aspect...rockshelters. Improvement of the elevation data in the Fort Hood GIS would provide better estimates of slope and aspect and might be expected to improve the...could be chosen and used as a control (non-sites). The development of Geographic Information Systems ( GIS ) allows either or both approaches to be

  10. Pulmonary adverse effects of welding fume in automobile assembly welders.

    PubMed

    Sharifian, Seyed Akbar; Loukzadeh, Ziba; Shojaoddiny-Ardekani, Ahmad; Aminian, Omid

    2011-01-01

    Welding is one of the key components of numerous manufacturing industries, which has potential physical and chemical health hazards. Many components of welding fumes can potentially affect the lung function. This study investigates the effects of welding fumes on lung function and respiratory symptoms among welders of an automobile manufacturing plant in Iran. This historical cohort study assesses 43 male welders and 129 office workers by a questionnaire to record demographic data, smoking habits, work history and respiratory symptoms as well as lung function status by spirometry. The average pulmonary function values of welders were lower relative to controls with dose-effect relationship between work duration and pulmonary function impairment. The prevalence of chronic bronchitis was higher in welders than controls. Our findings suggest that welders are at risk for pulmonary disease.

  11. Modeling of Fume Formation from Shielded Metal Arc Welding Process

    NASA Astrophysics Data System (ADS)

    Sivapirakasam, S. P.; Mohan, Sreejith; Santhosh Kumar, M. C.; Surianarayanan, M.

    2017-04-01

    In this study, a semi-empirical model of fume formation rate (FFR) from a shielded metal arc welding (SMAW) process has been developed. The model was developed for a DC electrode positive (DCEP) operation and involves the calculations of droplet temperature, surface area of the droplet, and partial vapor pressures of the constituents of the droplet to predict the FFR. The model was further extended for predicting FFR from nano-coated electrodes. The model estimates the FFR for Fe and Mn assuming constant proportion of other elements in the electrode. Fe FFR was overestimated, while Mn FFR was underestimated. The contribution of spatters and other mechanism in the arc responsible for fume formation were neglected. A good positive correlation was obtained between the predicted and experimental FFR values which highlighted the usefulness of the model.

  12. Statistical Analysis of Fort Hood Quality-of-Life Questionnaire.

    DTIC Science & Technology

    1978-10-01

    The objective of this work was to provide supplementary data analyses of data abstracted from the Quality - of - Life questionnaire developed earlier at...the Fort Hood Field Unit at the request of Headquarters, TRADOC Combined Arms Test Activity (TCATA). The Quality - of - Life questionnaire data were...to the Quality - of - Life questionnaire. These data were then intensively analyzed using analysis of variance and correlational techniques. The results

  13. Relation between various chromium compounds and some other elements in fumes from manual metal arc stainless steel welding.

    PubMed

    Matczak, W; Chmielnicka, J

    1993-03-01

    For the years 1987-1990 160 individual samples of manual metal arc stainless steel (MMA/SS) welding fumes from the breathing zone of welders in four industrial plants were collected. Concentrations of soluble and insoluble chromium (Cr) III and Cr VI compounds as well as of some other welding fume elements (Fe, Mn, Ni, F) were determined. Concentration of welding fumes in the breathing zone ranged from 0.2 to 23.4 mg/m3. Total Cr amounted to 0.005-0.991 mg/m3 (including 0.005-0.842 mg/m3 Cr VI). Total Cr content of fumes varied from 0.1 to 7.4%. The distribution of particular Cr compounds was: 52.6% soluble Cr (including 50.7% Cr VI), 65.5% total Cr VI, and 11.4% insoluble Cr VI. The results obtained indicate that MMA/SS welding is a process that could be highly hazardous to human health. Evaluation of occupational exposure has shown that MMA/SS welders may exceed the admissible concentrations of soluble and insoluble Cr VI forms as well as of Mn and Ni. In the plants investigated the sum of the ratios of concentrations of particular welding fumes in the breathing zone of welders exceeded corresponding maximum allowable concentration values by 24 times (including 17 times for total Cr VI). Due to the variety and changeability of particular parameters occurring in the working environment, the composition of MMA/SS welding fumes (in the welder's breathing zone) is so variable that it is not possible to assess the exposure by means of one universal exposure indicator (maximum additive hygienic limit value). The evaluation should be based on the results of measurements of concentrations of particular elements in welding fumes.

  14. Relation between various chromium compounds and some other elements in fumes from manual metal arc stainless steel welding.

    PubMed Central

    Matczak, W; Chmielnicka, J

    1993-01-01

    For the years 1987-1990 160 individual samples of manual metal arc stainless steel (MMA/SS) welding fumes from the breathing zone of welders in four industrial plants were collected. Concentrations of soluble and insoluble chromium (Cr) III and Cr VI compounds as well as of some other welding fume elements (Fe, Mn, Ni, F) were determined. Concentration of welding fumes in the breathing zone ranged from 0.2 to 23.4 mg/m3. Total Cr amounted to 0.005-0.991 mg/m3 (including 0.005-0.842 mg/m3 Cr VI). Total Cr content of fumes varied from 0.1 to 7.4%. The distribution of particular Cr compounds was: 52.6% soluble Cr (including 50.7% Cr VI), 65.5% total Cr VI, and 11.4% insoluble Cr VI. The results obtained indicate that MMA/SS welding is a process that could be highly hazardous to human health. Evaluation of occupational exposure has shown that MMA/SS welders may exceed the admissible concentrations of soluble and insoluble Cr VI forms as well as of Mn and Ni. In the plants investigated the sum of the ratios of concentrations of particular welding fumes in the breathing zone of welders exceeded corresponding maximum allowable concentration values by 24 times (including 17 times for total Cr VI). Due to the variety and changeability of particular parameters occurring in the working environment, the composition of MMA/SS welding fumes (in the welder's breathing zone) is so variable that it is not possible to assess the exposure by means of one universal exposure indicator (maximum additive hygienic limit value). The evaluation should be based on the results of measurements of concentrations of particular elements in welding fumes. PMID:8457491

  15. The detection of drugs of abuse in fingerprints using Raman spectroscopy II: cyanoacrylate-fumed fingerprints

    NASA Astrophysics Data System (ADS)

    Day, Joanna S.; Edwards, Howell G. M.; Dobrowski, Steven A.; Voice, Alison M.

    2004-07-01

    This paper describes the application of Raman spectroscopy to the detection of exogenous substances in cyanoacrylate-fumed fingerprints. The scenario considered was that of an individual handling a substance and subsequently depositing a contaminated fingerprint. These fingerprints were enhanced by cyanoacrylate fuming, a process in which a layer of white cyanoacrylate polymer is deposited on the fingerprint material, enabling visual detection. Five drugs of abuse (codeine phosphate, cocaine hydrochloride, amphetamine sulphate, barbital and nitrazepam) and five non-controlled substances of similar appearance, which may be used in the adulteration of drugs of abuse (caffeine, aspirin, paracetamol, starch and talc), were used. The substances studied could be clearly distinguished using their Raman spectra and were all successfully detected in cyanoacrylate-fumed fingerprints. Photobleaching was necessary to reduce the fluorescence background in the spectra of some substances. Raman spectra obtained from the substances in cyanoacrylate-fumed fingerprints were of a similar quality to spectra obtained from the substances under normal sampling conditions, however, interfering Raman bands arising from the cyanoacrylate polymer were present in the spectra. In most cases the only interfering band was the CN stretching mode of the polymer, and there were no cases where the interfering bands prevented identification of the substances. If necessary, the interfering bands could be successfully removed by spectral subtraction. The most difficult aspect of the detection of these substances in cyanoacrylate-fumed fingerprints was visually locating the substance in the fingerprint beneath the polymer layer in order to obtain a Raman spectrum.

  16. Methods for determining soluble and insoluble Cr III and Cr VI compounds in welding fumes.

    PubMed

    Matczak, W; Chmielnicka, J

    1989-01-01

    An analytical procedure for simultaneous determination of soluble and insoluble Cr III and Cr VI compounds in welding fumes has been proposed. In the welding fume samples collected on a membrane filter, total chromium was determined with atomic absorption spectrophotometry (AAS). Glass filters with collected samples were divided into two parts. In one part of the sample, soluble and insoluble chromium was determined by means of AAS. The separation of soluble chromium III and VI was carried out on diphenylcarbazide resin. In the second part of the sample total chromium VI was determined by means of the colorimetric method with s-diphenylcarbazide. The difference in the results of these determinations allowed the calculation of the content of total Cr III, Cr III insolub. and Cr VI insolub. The results of determining chromium compounds in welding fumes samples collected in the welder's breathing zone and in experimental chambers are also presented in this paper. The content of total chromium in the fumes determined by AAS (from a membrane filtr) and that calculated from the sum of soluble and insoluble chromium (from a glass filter) were concordant and within the limits of the admissible error for the method. Total chromium content in welding fume samples collected individually was found to range from 2.4-4.2%. The percentage of particular chromium compounds as compared to total chromium (100%) amounted: total Cr III--34%, total Cr VI--66%, soluble chromium--66% and in this Cr III--20% and Cr VI--43%, insoluble chromium--34% and in this: Cr III--14% and Cr VI--20%.

  17. Welding fumes from stainless steel gas metal arc processes contain multiple manganese chemical species.

    PubMed

    Keane, Michael; Stone, Samuel; Chen, Bean

    2010-05-01

    Fumes from a group of gas metal arc welding (GMAW) processes used on stainless steel were generated using three different metal transfer modes and four different shield gases. The objective was to identify and measure manganese (Mn) species in the fumes, and identify processes that are minimal generators of Mn species. The robotic welding system was operated in short-circuit (SC) mode (Ar/CO2 and He/Ar), axial spray (AXS) mode (Ar/O2 and Ar/CO2), and pulsed axial-spray (PAXS) mode (Ar/O2). The fumes were analyzed for Mn by a sequential extraction process followed by inductively coupled plasma-atomic emission spectroscopy (ICP-AES) analysis, and by X-ray diffraction (XRD). Total elemental Mn, iron (Fe), chromium (Cr) and nickel (Ni) were separately measured after aqua regia digestion and ICP-AES analysis. Soluble Mn2+, Fe2+, Fe3+, and Ni2+ in a simple biological buffer (phosphate-buffered saline) were determined at pH 7.2 and 5.0 after 2 h incubation at 37 C by ion chromatography. Results indicate that Mn was present in soluble form, acid-soluble form, and acid-soluble form after reduction by hydroxylamine, which represents soluble Mn0 and Mn2+ compounds, other Mn2+ compounds, and (Mn3+ and Mn4+) compounds, respectively. The dominant fraction was the acid-soluble Mn2+ fraction, but results varied with the process and shield gas. Soluble Mn mass percent in the fume ranged from 0.2 to 0.9%, acid-soluble Mn2+ compounds ranged from 2.6 to 9.3%, and acid plus reducing agent-soluble (Mn3+ and Mn4+) compounds ranged from 0.6 to 5.1%. Total Mn composition ranged from 7 to 15%. XRD results showed fumes had a crystalline content of 90-99% Fe3O4, and showed evidence of multiple Mn oxides, but overlaps and weak signals limited identification. Small amounts of the Mn2+ in the fume (<0.01 to ≈ 1% or <0.1 to ≈ 10 microg ml(-1)) and Ni2+ (<0.01 to ≈ 0.2% or <0.1 to ≈ 2 mg ml(-1)) ions were found in biological buffer media, but amounts were highly dependent on pH and the

  18. Human biomonitoring of chromium and nickel from an experimental exposure to manual metal arc welding fumes of low and high alloyed steel.

    PubMed

    Bertram, Jens; Brand, Peter; Schettgen, Thomas; Lenz, Klaus; Purrio, Ellwyn; Reisgen, Uwe; Kraus, Thomas

    2015-05-01

    The uptake and elimination of metals from welding fumes is currently not fully understood. In the Aachen Workplace Simulation Laboratory (AWSL) it is possible to investigate the impact of welding fumes on human subjects under controlled exposure conditions. In this study, the uptake and elimination of chromium or chromium (VI) respectively as well as nickel was studied in subjects after exposure to the emissions of a manual metal arc welding process using low or high alloyed steel. In this present study 12 healthy male non-smokers, who never worked as welders before, were exposed for 6h to welding fumes of a manual metal arc welding process. In a three-fold crossover study design, subjects were exposed in randomized order to either clean air, emissions from welding low alloyed steel, and emissions from welding high alloyed steel. Particle mass concentration of the exposure aerosol was 2.5mg m(-3). The content of chromium and nickel in the air was determined by analysing air filter samples on a high emission scenario. Urine analysis for chromium and nickel was performed before and after exposure using methods of human biomonitoring. There were significantly elevated chromium levels after exposure to welding fumes from high alloyed steel compared to urinary chromium levels before exposure to high alloyed welding fumes, as well as compared to the other exposure scenarios. The mean values increased from 0.27 µg l(-1) to 18.62 µg l(-1). The results were in good agreement with already existing correlations between external and internal exposure (German exposure equivalent for carcinogenic working materials EKA). The variability of urinary chromium levels was high. For urinary nickel no significant changes could be detected at all. Six-hour exposure to 2.5mg m(-3) high alloyed manual metal arc welding fumes lead to elevated urinary chromium levels far higher (7.11-34.16 µg l(-1)) than the German biological exposure reference value (BAR) of 0.6 µg l(-1) directly after

  19. Nickel-Refining Fumes Induced DNA Damage and Apoptosis of NIH/3T3 Cells via Oxidative Stress

    PubMed Central

    Wang, Yue; Wang, Sheng-Yuan; Jia, Li; Zhang, Lin; Ba, Jing-Chong; Han, Dan; Yu, Cui-Ping; Wu, Yong-Hui

    2016-01-01

    Although there have been numerous studies examining the toxicity and carcinogenicity of nickel compounds in humans and animals, its molecular mechanisms of action are not fully elucidated. In our research, NIH/3T3 cells were exposed to nickel-refining fumes at the concentrations of 0, 6.25, 12.50, 25, 50 and 100 μg/mL for 24 h. Cell viability, cell apoptosis, reactive oxygen species (ROS) level, lactate dehydrogenase (LDH) assay, the level of glutathione (GSH), activities of superoxide dismutase (SOD), catalase (CAT), and malondialdehyde (MDA) level were detected. The exposure of NIH/3T3 cells to nickel-refining fumes significantly reduced cell viability and induced cell apoptotic death in a dose-dependent manner. Nickel-refining fumes significantly increased ROS levels and induced DNA damage. Nickel-refining fumes may induce the changes in the state of ROS, which may eventually initiate oxidative stress, DNA damage and apoptosis of NIH/3T3 cells. PMID:27347984

  20. Removal of hexavalent chromium in soil and groundwater by supported nano zero-valent iron on silica fume.

    PubMed

    Li, Yongchao; Jin, Zhaohui; Li, Tielong; Li, Shujing

    2011-01-01

    Silica fume supported-Fe(0) nanoparticles (SF-Fe(0)) were prepared using commercial silica fume as a support. The feasibility of using this SF-Fe(0) for reductive immobilization of Cr(VI) was investigated through batch tests. Compared with unsupported Fe(0), SF-Fe(0) was significantly more active in Cr(VI) removal especially in 84 wt% silica fume loading. Silica fume had also been found to inhibit the formation of Fe(III)/Cr(III) precipitation on Fe nanoparticles' surface, which was increasing the deactivation resistance of iron. Cr(VI) was removed through physical adsorption of Cr(VI) onto the SF-Fe(0) surface and subsequent reduction of Cr(VI) to Cr(III). The rate of reduction of Cr(VI) could be expressed by pseudo first-order reaction kinetics. The rate constant increased with the increase in iron loading but decreased with the increase in initial Cr(VI) concentration. Furthermore, column tests showed that the SF-Fe(0) could be readily transported in model soil.

  1. Exposure to bitumen fumes and genotoxic effects on Turkish asphalt workers.

    PubMed

    Karaman, Ali; Pirim, Ibrahim

    2009-04-01

    Bitumen fumes consist essentially of polycyclic aromatic hydrocarbons (PAHs) and their derivatives, some of which are known to be carcinogenic or cocarcinogenic in humans. The aim of this study was to investigate exposure to asphalt fumes among Turkish asphalt workers and determine whether any effects could be detected with genotoxic tests. The study included 26 asphalt workers and 24 control subjects. Sister chromatid exchange (SCE) and micronucleus (MN) were determined in peripheral lymphocytes. Urinary 1-hydroxypyrene (1-OHP) excretion was used as a biomarker of occupational exposure to PAHs. The asphalt workers had a significant increase in SCEs and MN (for each, p < 0.001). A positive correlation existed between the duration of exposure and rates of SCE or MN frequencies (r = 0.49, p < 0.05; r = 0.53, p < 0.05, respectively). The concentration of 1-OHP in urine was higher for the asphalt workers than for the controls (p < 0.001). However, we found that there was no statistically significant correlation between the urinary 1-OHP concentration and SCEs or MN frequencies (r = 0.25, p > 0.5; r = 0.17, p > 0.5, respectively). This study shows that Turkish asphalt workers have an increased exposure to PAHs from bitumen fumes, and genotoxic effects could be detected by SCEs and MN tests.

  2. Fine water spray for fire extinguishing. Phase 2: Turbine hood

    NASA Astrophysics Data System (ADS)

    Aune, P.; Wighus, R.; Drangsholt, G.; Stensaas, J. P.

    1994-12-01

    SINTEF has carried out tests of a Fine Water Spray fire suppression system intended to be used as a replacement for Halon systems in turbine hoods on offshore platforms operated by British Petroleum Norway. The tests were carried out in a 70 cu m full scale model representing a turbine hood of the Ula platform in the North Sea. A mock-up of a gas turbine was installed in the model. The scope of work in Phase 2 was to verify the efficiency of fire suppression in realistic fire scenarios using a Fine Water Spray system, and to find an optimum procedure for water application in a fire situation. Two reports have been made from the experiments in Phase 2, one Main Report, STF25 A94036, and the present Technical Report, STF25 A94037. The discussion and conclusions are given in the Main Report while this Technical Report gives a more thorough presentation of the experimental setup and methods used for calibration and calculation of measured values. In addition, a complete set of curves for each experiment is included.

  3. 42 CFR 84.1136 - Facepieces, hoods, and helmets; eyepieces; minimum requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Facepieces, hoods, and helmets; eyepieces; minimum requirements. 84.1136 Section 84.1136 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE...

  4. 42 CFR 84.1136 - Facepieces, hoods, and helmets; eyepieces; minimum requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Facepieces, hoods, and helmets; eyepieces; minimum requirements. 84.1136 Section 84.1136 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE...

  5. 42 CFR 84.1136 - Facepieces, hoods, and helmets; eyepieces; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Facepieces, hoods, and helmets; eyepieces; minimum requirements. 84.1136 Section 84.1136 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE...

  6. 42 CFR 84.1136 - Facepieces, hoods, and helmets; eyepieces; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Facepieces, hoods, and helmets; eyepieces; minimum requirements. 84.1136 Section 84.1136 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE...

  7. 42 CFR 84.1136 - Facepieces, hoods, and helmets; eyepieces; minimum requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Facepieces, hoods, and helmets; eyepieces; minimum requirements. 84.1136 Section 84.1136 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE...

  8. Labia Minora, Labia Majora, and Clitoral Hood Alteration: Experience-Based Recommendations.

    PubMed

    Hunter, John G

    2016-01-01

    Aesthetic alteration of the genitalia is increasingly sought by women unhappy with the size, shape, and appearance of their vulva. Although the labia minora are usually the focus of concern, the entire anatomic region--minora, labia majora, clitoral hood, perineum, and mons pubis--should be evaluated in a preoperative assessment of women seeking labiaplasty. Labiaplasty is associated with high patient satisfaction and low complication rates. The three basic labia minora reduction techniques--edge excision, wedge excision, and central deepithelialization--as well as their advantages and disadvantages are discussed to assist the surgeon in tailoring technique selection to individual genital anatomy and aesthetic desires. We present key points of the preoperative anatomic evaluation, technique selection, operative risks, perioperative care, and potential complications for labia minora, labia majora, and clitoral hood alterations, based on a large operative experience. Labiaplasty competency should be part of the skill set of all plastic surgeons. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  9. Repetitive Dosing of Fumed Silica Leads to Profibrogenic Effects through Unique Structure–Activity Relationships and Biopersistence in the Lung

    DOE PAGES

    Sun, Bingbing; Wang, Xiang; Liao, Yu-Pei; ...

    2016-08-02

    Contrary to the notion that the use of fumed silica in consumer products can “generally (be) regarded as safe” (GRAS), the high surface reactivity of pyrogenic silica differs from other forms of synthetic amorphous silica (SAS), including the capacity to induce membrane damage and acute proinflammatory changes in the murine lung. Additionally, the chain-like structure and reactive surface silanols also allow fumed silica to activate the NLRP3 inflammasome, leading to IL-1β production. This pathway is known to be associated with subchronic inflammation and profibrogenic effects in the lung by α-quartz and carbon nanotubes. Different from the latter materials, bolus dosemore » instillation of 21 mg/kg fumed silica did not induce sustained IL-1β production or subchronic pulmonary effects. In contrast, the NLRP3 inflammasome pathway was continuously activated by repetitive-dose administration of 3 × 7 mg/kg fumed silica, 1 week apart. We also found that while single-dose exposure failed to induce profibrotic effects in the lung, repetitive dosing can trigger increased collagen production, even at 3 × 3 mg/kg. The change between bolus and repetitive dosing was due to a change in lung clearance, with recurrent dosing leading to fumed silica biopersistence, sustained macrophage recruitment, and activation of the NLRP3 pathway. These subchronic proinflammatory effects disappeared when less surface-reactive titanium-doped fumed silica was used for recurrent administration. Finally, these data indicate that while fumed silica may be regarded as safe for some applications, we should reconsider the GRAS label during repetitive or chronic inhalation exposure conditions.« less

  10. Medical Experts and Agnotology in the Fumes Controversy of the Huelva Copper Mines (1888–1890)

    PubMed Central

    Guillem-Llobat, Ximo

    2017-01-01

    Huelva’s copper mines (Spain) have been active for centuries but in the second half of the nineteenth century extractive activities in Riotinto, Tharsis, and other mines in the region were intensified in order to reach world leadership. The method used in these mines for copper extraction from low grade ores generated continuous emissions of fumes that were extremely controversial. The inhabitants had complained about the fumes for decades but as activity intensified so did complaints. The killing of anti-fumes demonstrators in 1888 led to the passing of a Royal Decree banning the open-air roasting of ore and to the drafting of numerous reports on the hazards of the fumes. Major state and provincial medical institutions, as well as renowned hygienists and engineers, took part in the assessment, contributing to a scientific controversy especially rich in content. In my paper I will analyse the production and circulation of knowledge and ignorance about the impact of fumes on public health, as well as the role of medical experts and expertise in the controversy. The analysis will focus on the reports drafted between the 1888 ban and its 1890 repeal, and will show the changing nature of the expert assessment and the numerous paths followed by experts in producing ignorance. The paper will conclude by considering other stakeholders, who may shed some light on the reasons behind the performance of the medical experts. PMID:28604295

  11. 6. VIEW OF THE BRIQUETTING PRESS AND CHIP CLEANING HOOD. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. VIEW OF THE BRIQUETTING PRESS AND CHIP CLEANING HOOD. SCRAPS OF ENRICHED URANIUM FROM MACHINING OPERATIONS WERE CLEANED IN A SOLVENT BATH, THEN PRESSED INTO BRIQUETTS. THE BRIQUETTS WERE USED AS FEED MATERIAL FOR THE FOUNDRY. (4/4/66) - Rocky Flats Plant, General Manufacturing, Support, Records-Central Computing, Southern portion of Plant, Golden, Jefferson County, CO

  12. Respiratory symptoms and lung functional impairments associated with occupational exposure to asphalt fumes.

    PubMed

    Neghab, M; Zare Derisi, F; Hassanzadeh, J

    2015-04-01

    Controversy exists as to the potential of asphalt fumes to induce respiratory symptoms and lung functional impairments. To examine the respiratory effects, if any, of occupational inhalation exposure to asphalt fumes. In this cross-sectional study, 74 asphalt workers and 110 unexposed employees were investigated. The prevalence of respiratory symptoms among subjects was investigated by a standard questionnaire. Additionally, the parameters of pulmonary function were measured both, prior to exposure and at the end of work-shift. Furthermore, to assess the extent to which workers were exposed to asphalt fumes, total particulate and the benzene-soluble fraction were measured in different worksites. The mean levels of exposure to total particulate and benzene-soluble fraction in asphalt fumes were estimated to be 0.9 (SD 0.2) and 0.3 (SD 0.1) mg/m^3, respectively. Mean values of FEV1, both prior to the exposure (89.58% [SD 18.69%] predicted value) and at the end of shift (85.38% [SD 19.4%]), were significantly (p<0.05) smaller than those of the comparison subjects (93.88% [SD 13.93%]). Similarly, pre-shift (87.05 [SD 8.57]) and postexposure (89.95 [SD 6.85]) FEV1/FVC ratio were both significantly (p<0.01) lower than those of the unexposed employees (107.56 [SD 9.64]). Moreover, the prevalence of respiratory symptoms such as cough and wheezing in exposed employees were 41% and 42%, respectively. The corresponding values for comparison subjects were 10.0% and 3.6%, respectively (p<0.001). The pattern of changes in parameters of lung function in asphalt workers was consistent with that of chronic obstructive lung disease. Significant decrements in the parameters of pulmonary function as well as, a significant increase in the prevalence of respiratory symptoms in asphalt paving workers compared to their unexposed counterparts provided evidence in favor of a significant association between exposure to asphalt fumes and lung function impairments.

  13. Nitrous oxide as a tracer gas in the ASHRAE 110-1995 Standard.

    PubMed

    Burke, Martin; Wong, Larry; Gonzales, Ben A; Knutson, Gerhard

    2014-01-01

    ANSI/ASHRAE Standard 110 provides a quantitative method for testing the performance of laboratory fume hoods. Through release of a known quantity (4.0 Lpm) of a tracer gas, and subsequent monitoring of the tracer gas concentration in the "breathing zone" of a mannequin positioned in front of the hood, this method allows for evaluation of laboratory hood performance. Standard 110 specifies sulfur hexafluoride (SF6) as the tracer gas; however, suitable alternatives are allowed. Through three series of performance tests, this analysis serves to investigate the use of nitrous oxide (N2O) as an alternate tracer gas for hood performance testing. Single gas tests were performed according to ASHRAE Standard 110-1995 with each tracer gas individually. These tests showed identical results using an acceptance criterion of AU 0.1 with the sash half open, nominal 18 inches (0.46m) high, and the face velocity at a nominal 60 fpm (0.3 m/s). Most data collected in these single gas tests, for both tracer gases, were below the minimum detection limit, thus two dual gas tests were developed for simultaneous sampling of both tracer gases. Dual gas dual ejector tests were performed with both tracer gases released simultaneously through two ejectors, and the concentration measured with two detectors using a common sampling probe. Dual gas single ejector tests were performed with both tracer gases released though a single ejector, and the concentration measured in the same manner as the dual gas dual ejector tests. The dual gas dual ejector tests showed excellent correlation, with R typically greater than 0.9. Variance was observed in the resulting regression line for each hood, likely due to non-symmetry between the two challenges caused by variables beyond the control of the investigators. Dual gas single ejector tests resulted in exceptional correlation, with R>0.99 typically for the consolidated data, with a slope of 1.0. These data indicate equivalent results for ASHRAE 110

  14. Nickel-smelting fumes increased the expression of HIF-1α through PI3K/ERK pathway in NIH/3T3 cells

    PubMed Central

    Han, Dan; Yang, Yue; Zhang, Lin; Wang, Chao; Wang, Yue; Tan, Wen-Qiao; Hu, Xue-Ying; Wu, Yong-Hui

    2016-01-01

    Objective: The purpose of this study was to investigate the effects of Nickel (Ni) -smelting fumes on oncogenic proteins in vivo and in vitro. Methods: Ni fallout beside a Ni smelting furnace in a factory was sampled to study its toxic effect. The effects of Ni-smelting fumes on the regulation of PI3K and ERK signaling pathways and the important downstream hypoxia inducible factor, HIF-1α, were studied both in NIH/3T3 cells and in the lung tissue of rats. NIH/3T3 cell transformation induced by Ni-smelting fumes was also observed. Results: Ni-smelting fumes activated PI3K, p-AKT, p70S6K1, and ERK proteins and increased HIF-1α expression in a time- and dose-dependent manner. However, activation was suppressed when NIH/3T3 cells were pretreated with PI3K/AKT or ERK inhibitors. Ni-smelting fumes caused malignant transformation of NIH/3T3 cells. Conclusions: Ni-smelting fumes increased the expression of HIF-1α through the PI3K/ERK pathway in NIH/3T3 cells and induced malignant transformation in these cells indicating that Ni-smelting fumes may be a potential carcinogen in mammalian cells. PMID:27488040

  15. Inflammatory response in rat lungs with recurrent exposure to welding fumes: a transcriptomic approach.

    PubMed

    Oh, Jung-Hwa; Yang, Mi-Jin; Heo, Jeong-Doo; Yang, Young-Su; Park, Han-Jin; Park, Se-Myo; Kwon, Myung-Sang; Song, Chang-Woo; Yoon, Seokjoo; Yu, Il Je

    2012-04-01

    As chronic exposure to welding fumes causes pulmonary diseases, such as pneumoconiosis, public concern has increased regarding continued exposure to these hazardous gases in the workplace. In a previous study, the inflammatory response to welding fume exposure was analysed in rat lungs in the case of recurrent exposure and recovery periods. Thus using lung samples, well-annotated by histological observation and biochemical analysis, this study examines the gene expression profiles to identify phenotype-anchored genes corresponding to lung inflammation and the repair phenomenon after recurrent welding fume exposure. Seven genes (Mmp12, Cd5l, LOC50101, LOC69183, Spp1, and Slc26a4) were found to be significantly up-regulated according to the severity of the lung injury. In addition, the transcription and translation of Trem2, which was up-regulated in response to the repair process, were validated using a real-time polymerase chain reaction, Western blotting, and immunohistochemistry. The differentially expressed genes in the exposure and recovery groups were also classified using k-means and hierarchical clustering, plus their toxicological function and canonical pathways were further analysed using Ingenuity Pathways Analysis Software. As a result, this comprehensive and integrative analysis of the transcriptional changes that occur during repeated exposure provides important information on the inflammation and repair processes after welding-fume-induced lung injury.

  16. Evolution of Welding-Fume Aerosols with Time and Distance from the Source: A study was conducted on the spatiotemporal variability in welding-fume concentrations for the characterization of first- and second-hand exposure to welding fumes.

    PubMed

    Cena, L G; Chen, B T; Keane, M J

    2016-08-01

    Gas metal arc welding fumes were generated from mild-steel plates and measured near the arc (30 cm), representing first-hand exposure of the welder, and farther away from the source (200 cm), representing second-hand exposure of adjacent workers. Measurements were taken during 1-min welding runs and at subsequent 5-min intervals after the welding process was stopped. Number size distributions were measured in real time. Particle mass distributions were measured using a micro-orifice uniform deposition impactor, and total mass concentrations were measured with polytetrafluorothylene filters. Membrane filters were used for collecting morphology samples for electron microscopy. Average mass concentrations measured near the arc were 45 mg/m 3 and 9 mg/m 3 at the farther distance. The discrepancy in concentrations at the two distances was attributed to the presence of spatter particles, which were observed only in the morphology samples near the source. As fumes aged over time, mass concentrations at the farther distance decreased by 31% (6.2 mg/m 3 ) after 5 min and an additional 13% (5.4 mg/m 3 ) after 10 min. Particle number and mass distributions during active welding were similar at both distances, indicating similar exposure patterns for welders and adjacent workers. Exceptions were recorded for particles smaller than 50 nm and larger than 3 μm, where concentrations were higher near the arc, indicating higher exposures of welders. These results were confirmed by microscopy analysis. As residence time increased, number concentrations decreased dramatically. In terms of particle number concentrations, second-hand exposures to welding fumes during active welding may be as high as first-hand exposures.

  17. Comparisons between Shikoro-type helmet with no hood and typical fire protective helmets with hood in a hot and humid environment.

    PubMed

    Baek, Yoon Jeong; Jung, Dahee; Son, Su-Young; Lee, Joo-Young

    2018-03-01

    The purpose of this study was to evaluate physiological and subjective responses while wearing the Shikoro-type helmet for firefighters when compared to typical helmets. Eight firefighters conducted a 30-min exercise at a 5 km h -1 in three helmet conditions at an air temperature of 32 °C with 70%RH. The results showed that no significant differences in rectal, mean skin temperature and physiological strain index among the three conditions were found during exercise and recovery. Skin temperatures on the cheek, ear and neck during exercise were significantly lower for the Shikoro-type condition (p < 0.05), but forehead temperature was greater for the Shikoro-type helmet when compared to the other conditions (p < 0.05). Statistical differences in thermal sensation and thermal comfort for overall and local body regions were not found among the three conditions. These results imply that the Shikoro-type helmet had local advantages in reducing skin temperatures on the face and neck. Practitioner Summary: Firefighters wear their helmet with its hood to protect the head and neck but a Shikoro type helmet has no fire protective hood. This study aimed to evaluate the comfort function of Shikoro helmet along with typical helmets. The results demonstrated thermal benefits of the Shikoro helmet on the head.

  18. The Relationship of Welding Fume Exposure, Smoking, and Pulmonary Function in Welders.

    PubMed

    Roach, Laura L

    2018-01-01

    The purpose of this study was to explore the relationship between occupational exposure to welding fumes and pulmonary function in an effort to add supportive evidence and clarity to the current body of research. This study utilized a retrospective chart review of pulmonary function testing and pulmonary questionnaires already available in charts from preplacement physicals to the most recent test. When comparing smokers to nonsmokers, utilizing multiple regression and controlling for age and percentage of time using a respirator, years welding was statistically significant at p = .04. Data support that smoking has a synergistic effect when combined with welding fume exposure on pulmonary decline.

  19. Systemic serum amyloid A as a biomarker for exposure to zinc and/or copper-containing metal fumes.

    PubMed

    Baumann, R; Gube, M; Markert, A; Davatgarbenam, S; Kossack, V; Gerhards, B; Kraus, T; Brand, P

    2018-01-01

    Zinc- and copper-containing welding fumes increase systemic C-reactive protein (CRP). The aim of this study was to investigate the performance of the biomarkers serum amyloid A (SAA) and soluble vascular cell adhesion molecule-1 (VCAM-1) in this regard. Fifteen male subjects were exposed under controlled conditions to welding fumes containing either zinc, or copper, or copper and zinc for 6 h. Plasma samples were collected before, 6 and 24 h after start of exposure and biomarkers therein were measured by electrochemiluminescent assay. For each exposure, systemic concentrations of systemic SAA, but not VCAM-1, increased significantly at 24 h after exposure start compared with baseline ("copper only": P=0.0005, "zinc only": P=0.027, "copper and zinc": P=0.001). SAA showed a wider range of concentrations than did CRP and its levels increased up to 19-fold after welding fume exposure. The recognition of copper as a potential harmful component in welding fumes, also independent from zinc, deserves further consideration. SAA might represent a new sensitive biomarker for potential subclinical sterile inflammation after inhalation of copper- and/or zinc-containing welding fumes. As elevations of CRP and SAA protein have both been linked to a higher risk for cardiovascular disease, these findings might particularly be important for long-term welders.

  20. Evaluation of one-step luminescent cyanoacrylate fuming.

    PubMed

    Khuu, Alicia; Chadwick, Scott; Spindler, Xanthe; Lam, Rolanda; Moret, Sébastien; Roux, Claude

    2016-06-01

    One-step luminescent cyanoacrylates have recently been introduced as an alternative to the conventional cyanoacrylate fuming methods. These new techniques do not require the application of a luminescent post-treatment in order to enhance cyanoacrylate-developed fingermarks. In this study, three one-step polymer cyanoacrylates: CN Yellow Crystals (Aneval Inc.), PolyCyano UV (Foster+Freeman Ltd.) and PECA Multiband (BVDA), and one monomer cyanoacrylate: Lumikit™ (Crime Scene Technology), were evaluated against a conventional two-step cyanoacrylate fuming method (Cyanobloom (Foster+Freeman Ltd.) with rhodamine 6G stain). The manufacturers' recommended conditions or conditions compatible with the MVC™ 1000/D (Foster+Freeman Ltd.) were assessed with fingermarks aged for up to 8 weeks on non-porous and semi-porous substrates. Under white light, Cyanobloom generally gave better development than the one-step treatments across the substrates. Similarly when viewed under the respective luminescent conditions, Cyanobloom with rhodamine 6G stain resulted in improved contrast against the one-step treatments except on polystyrene, where PolyCyano UV and PECA Multiband gave better visualisation. Rhodamine 6G post-treatment of one-step samples did not significantly enhance the contrast of any of the one-step treatments against Cyanobloom/rhodamine 6G-treated samples. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. Mathematical modeling of thermal stresses in basic oxygen furnace hood tubes

    NASA Astrophysics Data System (ADS)

    Samarasekera, I. V.

    1985-06-01

    The stress-strain history of Basic Oxygen Furnace hood tubes during thermal cycling has been computed using heat flow and stress analyses. The steady-state temperature distribution in a transverse section of the tube was computed at a location where gas temperature in the hood could be expected to be a maximum. Calculations were performed for peak gas temperatures in the range 1950 to 2480 °C (3500 to 4500 °F). The stress-strain history of an element of material located at the center of the tube hot face was traced for three consecutive cycles using elasto-plastic finite-element analysis. It has been shown that the state of stress in the element alternates between compression and tension as the tube successively heats and cools. Yielding and plastic flow occurs at the end of each half of a given cycle. It was postulated that owing to repctitive yielding, plastic strain energy accumulates causing failure of the tubes by fatigue in the low cycle region. Using fatigue theory a conservative estimate for tube life was arrived at. In-plant observations support this mechanism of failure, and the number of cycles within which tube cracking was observed compares reasonably with model predictions. Utilizing the heat flow and stress models it was recommended that tube life could be enhanced by changing the tube material to ARMCO 17-4 pH or AISI 405 steel or alternatively reconstructing hoods with AISI 316L tubes of reduced thickness. These recommendations were based on the criterion that low-cycle fatigue failure could be averted if the magnitude of the cyclic strain could be reduced or if macroscopic plastic flow could be prevented.

  2. Global metabolomic profiling reveals an association of metal fume exposure and plasma unsaturated fatty acids.

    PubMed

    Wei, Yongyue; Wang, Zhaoxi; Chang, Chiung-yu; Fan, Tianteng; Su, Li; Chen, Feng; Christiani, David C

    2013-01-01

    Welding-associated air pollutants negatively affect the health of exposed workers; however, their molecular mechanisms in causing disease remain largely unclear. Few studies have systematically investigated the systemic toxic effects of welding fumes on humans. To explore the effects of welding fumes on the plasma metabolome, and to identify biomarkers for risk assessment of welding fume exposure. The two-stage, self-controlled exploratory study included 11 boilermakers from a 2011 discovery panel and 8 boilermakers from a 2012 validation panel. Plasma samples were collected pre- and post-welding fume exposure and analyzed by chromatography/mass spectrometry. Eicosapentaenoic or docosapentaenoic acid metabolic changes post-welding were significantly associated with particulate (PM2.5) exposure (p<0.05). The combined analysis by linear mixed-effects model showed that exposure was associated with a statistically significant decline in metabolite change of eicosapentaenoic acid [β(95% CI) = -0.013(-0.022 ≈ -0.004); p = 0.005], docosapentaenoic acid n3 [β(95% CI) = -0.010(-0.018 ≈ -0.002); p = 0.017], and docosapentaenoic acid n6 [β(95% CI) = -0.007(-0.013 ≈ -0.001); p = 0.021]. Pathway analysis identified an association of the unsaturated fatty acid pathway with exposure (p Study-2011 = 0.025; p Study-2012 = 0.021; p Combined = 0.009). The functional network built by these fatty acids and their interactive genes contained significant enrichment of genes associated with various diseases, including neoplasms, cardiovascular diseases, and lipid metabolism disorders. High-dose exposure of metal welding fumes decreases unsaturated fatty acids with an exposure-response relationship. This alteration in fatty acids is a potential biological mediator and biomarker for exposure-related health disorders.

  3. Effect of silica fume on the fresh and hardened properties of fly ash-based self-compacting geopolymer concrete

    NASA Astrophysics Data System (ADS)

    Memon, Fareed Ahmed; Nuruddin, Muhd Fadhil; Shafiq, Nasir

    2013-02-01

    The effect of silica fume on the fresh and hardened properties of fly ash-based self-compacting geopolymer concrete (SCGC) was investigated in this paper. The work focused on the concrete mixes with a fixed water-to-geopolymer solid (W/Gs) ratio of 0.33 by mass and a constant total binder content of 400 kg/m3. The mass fractions of silica fume that replaced fly ash in this research were 0wt%, 5wt%, 10wt%, and 15wt%. The workability-related fresh properties of SCGC were assessed through slump flow, V-funnel, and L-box test methods. Hardened concrete tests were limited to compressive, splitting tensile and flexural strengths, all of which were measured at the age of 1, 7, and 28 d after 48-h oven curing. The results indicate that the addition of silica fume as a partial replacement of fly ash results in the loss of workability; nevertheless, the mechanical properties of hardened SCGC are significantly improved by incorporating silica fume, especially up to 10wt%. Applying this percentage of silica fume results in 4.3% reduction in the slump flow; however, it increases the compressive strength by 6.9%, tensile strength by 12.8% and flexural strength by 11.5%.

  4. Pulmonary inflammation and tumor induction in lung tumor susceptible A/J and resistant C57BL/6J mice exposed to welding fume.

    PubMed

    Zeidler-Erdely, Patti C; Kashon, Michael L; Battelli, Lori A; Young, Shih-Houng; Erdely, Aaron; Roberts, Jenny R; Reynolds, Steven H; Antonini, James M

    2008-09-08

    Welding fume has been categorized as "possibly carcinogenic" to humans. Our objectives were to characterize the lung response to carcinogenic and non-carcinogenic metal-containing welding fumes and to determine if these fumes caused increased lung tumorigenicity in A/J mice, a lung tumor susceptible strain. We exposed male A/J and C57BL/6J, a lung tumor resistant strain, by pharyngeal aspiration four times (once every 3 days) to 85 mug of gas metal arc-mild steel (GMA-MS), GMA-stainless steel (SS), or manual metal arc-SS (MMA-SS) fume, or to 25.5 mug soluble hexavalent chromium (S-Cr). Shams were exposed to saline vehicle. Bronchoalveolar lavage (BAL) was done at 2, 7, and 28 days post-exposure. For the lung tumor study, gross tumor counts and histopathological changes were assessed in A/J mice at 48 and 78 weeks post-exposure. BAL revealed notable strain-dependent differences with regards to the degree and resolution of the inflammatory response after exposure to the fumes. At 48 weeks, carcinogenic metal-containing GMA-SS fume caused the greatest increase in tumor multiplicity and incidence, but this was not different from sham. By 78 weeks, tumor incidence in the GMA-SS group versus sham approached significance (p = 0.057). A significant increase in perivascular/peribronchial lymphoid infiltrates for the GMA-SS group versus sham and an increased persistence of this fume in lung cells compared to the other welding fumes was found. The increased persistence of GMA-SS fume in combination with its metal composition may trigger a chronic, but mild, inflammatory state in the lung possibly enhancing tumorigenesis in this susceptible mouse strain.

  5. [Assessment of occupational exposure of welders based on determination of fumes and their components produced during stainless steel welding].

    PubMed

    Stanisławska, Magdalena; Janasik, Beata; Trzcinka-Ochocka, Małgorzata

    2011-01-01

    Occupational exposure to welding fumes is a known health hazard. The aim of this study was to determine concentrations of welding fumes components such as: iron, manganese, nickel and chromium (including chromium speciation) to assess exposure of stainless steel welders. The survey covered 14 workers of two metallurgic plants engaged in welding stainless steel (18% Cr and 8% Ni) by different techniques: manual metal arc (MMA), metal inert gas (MIG) and tungsten inert gas (TIG). Personal air samples were collected in the welders' breathing zone over a period of about 6-7 h (dust was collected on a membrane and glass filter) to determine time weighted average (TWA) concentration of welding fumes and its components. The concentrations of welding fumes (total particulate) were determined with use of the gravimetric method. Concentrations and welding fume components, such as: iron, manganese, nickel and chromium were determined by ICP-MS technique. The total hexavalent chromium was analyzed by applying the spectrophotometry method according to NIOSH. The water-soluble chromium species were analyzed by HPLC-ICP-MS. Time weighted average concentrations of the welding fumes and its components at the worker's breathing zone were (mg/m3): dust, 0.14-10.7; iron, 0.004-2.9; manganese, 0.001-1.12; nickel, < 0.001-0.2; and chromium <0.002-0.85 (mainly Cr(III) and insoluble Cr(VI)). The maximum admissible limits for workplace pollutants (TLV-TWA) were exceeded for manganese and for insoluble chromium Cr (VI). For Cr (III) the limit was exceeded in individual cases. The assessment of the workers' occupational exposure, based on the determined time weighted average (TWA) of fumes and their components, shows that the stainless steel welders worked in conditions harmful to their health owing to the significantly exceeded maximum admissible limits for manganese and the exceeded TLV value for insoluble chromium (VI).

  6. Formation of a Bright Polar Hood over the Summer North Pole of Saturn in 2016

    NASA Astrophysics Data System (ADS)

    Sayanagi, Kunio M.; Blalock, John J.; Ingersoll, Andrew P.; Dyudina, Ulyana A.; Ewald, Shawn P.

    2016-10-01

    We report that a bright polar hood has formed over the north pole of Saturn, seen first in images captured by the Cassini ISS camera in 2016. When the north pole was observed during the previous period of Cassini spacecraft's high-inclination orbits in 2012-2013, the concentration of light-scattering aerosols within 2-degree latitude of the north pole appeared to be less than that of the surrounding region, and appeared as a dark hole in all ISS filters, in particular in the shorter wavelength filters BL1 (460 nm), and VIO (420 nm). The north pole's appearance in 2012 was in contrast to that of the south pole in 2007, when the south pole had a bright polar hood in those short wavelengths; the south pole appeared dark in all other ISS filters in 2007. The difference between the south pole in 2007 and the north pole in 2012 was interpreted to be seasonal; in 2007, Saturn was approaching the equinox of 2009 and the south pole had been continuously illuminated since the previous equinox in 1995. In 2012, the north pole had been illuminated for only ~3 years after the long winter polar night. The bright hood over the summer south pole in 2007 was hypothesized to consist of aerosols produced by ultraviolet photodissociation of hydrocarbon molecules. Fletcher et al (2015) predicted that a similar bright hood should form over the north pole as Saturn approaches the 2017 solstice. In 2016, the Cassini spacecraft raised its orbital inclination again in preparation for its Grande Finale phase of the mission, from where it has a good view of the north pole. New images captured in 2016 show that the north pole has developed a bright polar hood. We present new images of the north polar region captured in 2016 that show the north pole, and other seasonally evolving high-latitude features including the northern hexagon. Our research has been supported by the Cassini Project, NASA grants OPR NNX11AM45G, CDAPS NNX15AD33G PATM NNX14AK07G, and NSF grant AAG 1212216.

  7. Manganese distribution in brains of Sprague-Dawley rats after 60 days of stainless steel welding-fume exposure.

    PubMed

    Yu, Il Je; Park, Jung Duck; Park, Eon Sub; Song, Kyung Seuk; Han, Kuy Tae; Han, Jeong Hee; Chung, Yong Hyun; Choi, Byung Sun; Chung, Kyu Hyuck; Cho, Myung Haing

    2003-12-01

    Welders working in a confined space, as in the shipbuilding industry, are at risk of being exposed to high concentrations of welding fumes and developing pneumoconiosis or other welding-fume exposure related diseases. Among such diseases, manganism resulting from welding-fume exposure remains a controversial issue, as the movement of manganese into specific brain regions has not yet been clearly established. Accordingly, to investigate the distribution of manganese in the brain after welding-fume exposure, male Sprague-Dawley rats were exposed to welding fumes generated from manual metal arc-stainless steel (MMA-SS) at concentrations of 63.6 +/- 4.1 mg/m(3) (low dose, containing 1.6 mg/m(3) Mn) and 107.1 +/- 6.3 mg/m(3) (high dose, containing 3.5 mg/m(3) Mn) total suspended particulate (TSP) for 2 h per day in an inhalation chamber over a 60-day period. Blood, brain, lung, and liver samples were collected after 2 h, 15, 30, and 60 days of exposure and the tissues analyzed for their manganese concentrations using an atomic absorption spectrophotometer. Although dose- and time-dependent increases in the manganese concentrations were found in the lungs and livers of the rats exposed for 60 days, only slight manganese increases were observed in the blood during this period. Major statistically significant increases in the brain manganese concentrations were detected in the cerebellum after 15 days of exposure and up until 60 days. Slight increases in the manganese concentrations were also found in the substantia nigra, basal ganglia (caudate nucleus, putamen, and globus pallidus), temporal cortex, and frontal cortex, thereby indicating that the pharmacokinetics and distribution of the manganese inhaled from the welding fumes were different from those resulting from manganese-only exposure.

  8. 42 CFR 84.1153 - Dust, fume, mist, and smoke tests; canister bench tests; gas masks canisters containing filters...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist; Pesticide... 42 Public Health 1 2014-10-01 2014-10-01 false Dust, fume, mist, and smoke tests; canister bench...

  9. 42 CFR 84.1153 - Dust, fume, mist, and smoke tests; canister bench tests; gas masks canisters containing filters...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist; Pesticide... 42 Public Health 1 2013-10-01 2013-10-01 false Dust, fume, mist, and smoke tests; canister bench...

  10. 42 CFR 84.1153 - Dust, fume, mist, and smoke tests; canister bench tests; gas masks canisters containing filters...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist; Pesticide... 42 Public Health 1 2010-10-01 2010-10-01 false Dust, fume, mist, and smoke tests; canister bench...

  11. 42 CFR 84.1153 - Dust, fume, mist, and smoke tests; canister bench tests; gas masks canisters containing filters...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist; Pesticide... 42 Public Health 1 2011-10-01 2011-10-01 false Dust, fume, mist, and smoke tests; canister bench...

  12. 42 CFR 84.1153 - Dust, fume, mist, and smoke tests; canister bench tests; gas masks canisters containing filters...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist; Pesticide... 42 Public Health 1 2012-10-01 2012-10-01 false Dust, fume, mist, and smoke tests; canister bench...

  13. The mammalian spot test and its use for the testing of potential carcinogenicity of welding fume particles and hexavalent chromium.

    PubMed

    Knudsen, I

    1980-07-01

    Welding fume particles, potassium chromate and cyclophosphamide are tested in the mammalian spot test. Female mice C57BL/6J/BOM9 weeks old have been mated to T-stock male mice and treated with welding fume particles 100 mg/kg, potassium chromate 20 or 10 mg/kg, or cyclophosphamide 10 or 2.5 mg/kg intraperitoneally at day 8, 9 and 10 of pregnancy. The fur of the offspring was checked week 2 through week 5 after birth for coloured spots. The characterisation of the different types of spots are discussed. Welding fume particles 100 mg/kg and potassium chromate 10 mg/kg induce approximately to the same extent as cyclophosphamde 2.5 mg/kg, grayish or brownish spots in tvo screening test for mutagenic and carcinogenic potential of chemicals. The positive results for potassium chromate and cyclophosphamide are in agreement with previous in vitro experiments and confirm the sensitivity of the test. The effect of welding fume particles in this in vivo system suggests a potential risk for humans directly exposed to welding fumes.

  14. Control of exposure to hexavalent chromium concentration in shielded metal arc welding fumes by nano-coating of electrodes.

    PubMed

    Sivapirakasam, S P; Mohan, Sreejith; Santhosh Kumar, M C; Thomas Paul, Ashley; Surianarayanan, M

    2017-04-01

    Background Cr(VI) is a suspected human carcinogen formed as a by-product of stainless steel welding. Nano-alumina and nano-titania coating of electrodes reduced the welding fume levels. Objective To investigate the effect of nano-coating of welding electrodes on Cr(VI) formation rate (Cr(VI) FR) from a shielded metal arc welding process. Methods The core welding wires were coated with nano-alumina and nano-titania using the sol-gel dip coating technique. Bead-on plate welds were deposited on SS 316 LN plates kept inside a fume test chamber. Cr(VI) analysis was done using an atomic absorption spectrometer (AAS). Results A reduction of 40% and 76%, respectively, in the Cr(VI) FR was observed from nano-alumina and nano-titania coated electrodes. Increase in the fume level decreased the Cr(VI) FR. Discussion Increase in fume levels blocked the UV radiation responsible for the formation of ozone thereby preventing the formation of Cr(VI).

  15. The association between cooking oil fume exposure during pregnancy and birth weight: A prospective mother-child cohort study.

    PubMed

    Wang, Lingling; Hu, Weiyue; Guan, Quanquan; Du, Guizhen; Chen, Ting; Wu, Wei; Wang, Yun; Wang, Xinru; Xia, Yankai

    2018-01-15

    Effects of indoor air pollution on neonatal birth weight has been studied for many years. In China, cooking oil fumes are important parts of indoor air pollution. However, whether cooking oil fume exposure during pregnancy affects birth weight in China remains poorly understood. The objective of this study was to examine the association between pregnancy exposure to cooking oil fumes and birth weight in a newly established prospective mother-child cohort in China. We finally included 1420 pregnant women from 2013 to 2015 and follow up for one year until the offspring was born. According to self-reported exposure status, we categorized mothers into non-exposure group and exposed group or three exposure time subgroups, including 0h/day, 0-1h/day and >1h/day respectively. By using multinomial logistics regression models, we found that pregnancy exposure to cooking oil fumes significantly increased the risk of large for gestational age (LGA, OR=1.58, 95% CI=1.15-2.18, P=4.88×10 -3 ). Additionally, compared to pregnant women who were in non-exposure group, 0-1h/day exposure elevated the risk of LGA (OR=1.69, 95% CI=1.22-2.33, P=1.63×10 -3 ), while >1h/day exposure elevated the risk of small for gestational age, but were not significant (SGA, OR=2.15, 95% CI=0.61-7.66, P=0.24). In the stratification analysis, women aged 25-29years and ≥30years were predisposed to the influence of cooking oil fumes and have LGA newborns (OR=1.73, 95% CI=1.09-2.75, P=0.02; OR=1.72, 95% CI=1.07-2.77, P=0.02, respectively). In conclusion, the present study suggests inverse U-shape dose response association between maternal exposure to cooking oil fumes during pregnancy and birth weight, and further studies are needed to verify the effect of cooking oil fumes on the birth weight. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Characterization of the early pulmonary inflammatory response associated with PTFE fume exposure

    NASA Technical Reports Server (NTRS)

    Johnston, C. J.; Finkelstein, J. N.; Gelein, R.; Baggs, R.; Oberdorster, G.; Clarkson, T. W. (Principal Investigator)

    1996-01-01

    Heating of polytetrafluoroethylene (PTFE) has been described to release fumes containing ultrafine particles (approximately 18 nm diam). These fumes can be highly toxic in the respiratory tract inducing extensive pulmonary edema with hemorrhagic inflammation. Fischer-344 rats were exposed to PTFE fumes generated by temperatures ranging from 450 to 460 degrees C for 15 min at an exposure concentration of 5 x 10(5) particles/cm3, equivalent to approximately 50 micrograms/m3. Responses were examined 4 hr post-treatment when these rats demonstrated 60-85% neutrophils (PMNs) in their lung lavage. Increases in abundance for messages encoding the antioxidants manganese superoxide dismutase and metallothionein (MT) increased 15- and 40-fold, respectively. For messages encoding the pro- and anti-inflammatory cytokines: inducible nitric oxide synthase, interleukin 1 alpha, 1 beta, and 6 (IL-1 alpha, IL-1 beta, and IL-6), macrophage inflammatory protein-2, and tumor necrosis factor-alpha (TNF alpha) increases of 5-, 5-, 10-, 40-, 40-, and 15-fold were present. Vascular endothelial growth factor, which may play a role in the integrity of the endothelial barrier, was decreased to 20% of controls. In situ sections were hybridized with 33P cRNA probes encoding IL-6, MT, surfactant protein C, and TNF alpha. Increased mRNA abundance for MT and IL-6 was expressed around all airways and interstitial regions with MT and IL-6 demonstrating similar spatial distribution. Large numbers of activated PMNs expressed IL-6, MT, and TNF alpha. Additionally, pulmonary macrophages and epithelial cells were actively involved. These observations support the notion that PTFE fumes containing ultrafine particles initiate a severe inflammatory response at low inhaled particle mass concentrations, which is suggestive of an oxidative injury. Furthermore, PMNs may actively regulate the inflammatory process through cytokine and antioxidant expression.

  17. Archaeological Survey at Fort Hood, Texas Fiscal Year 1987: The MCA range Construction, Pidcoke Land Exchange, and Phantom Range Projects. Archeological Resource Management Series Research Report Number 23

    DTIC Science & Technology

    1991-01-01

    ORGANIZATION NAME AND ADORES$ 10. PROGRAM ELEMENT. PROJECT. TASK AREA G WORK UNIT NUMBERS Archeological Research Laboratory Texas A&M University College Station...V’Avail and/or • G O8IRZ This report summarizes the results of an archeological survey conducted for the U.S. Army at Fort Hood, Texas, by personnel from...it forms numerous round-topped buttes and outliers where the Edwards cap is eroded away. Overly-,, g the Comanche Peak formation is the Edwards

  18. Effects of Growth Conditions on the Measured Electrical Properties of Monolayer Molybdenum Disulfide

    DTIC Science & Technology

    2017-02-01

    rpm (thickness around 300 nm) and then baked on a hotplate at 185 °C for 2 min. The PMMA was exposed using a proximity effect correction with a base...and then soft baked at 50 °C in air for 30 min. After air-drying in a fume hood for an additional 3 h at room temperature, the PMMA was scraped from

  19. Microarray-based analysis of the lung recovery process after stainless-steel welding fume exposure in Sprague-Dawley rats.

    PubMed

    Oh, Jung-Hwa; Yang, Mi-jin; Yang, Young-Su; Park, Han-Jin; Heo, Sun Hee; Lee, Eun-Hee; Song, Chang-Woo; Yoon, Seokjoo

    2009-02-01

    Repeated exposure to welding fumes promotes a reversible increase in pulmonary disease risk, but the molecular mechanisms by which welding fumes induce lung injury and how the lung recovers from such insults are unclear. In the present study, pulmonary function and gene-expression profiles in the lung were analyzed by Affymetrix GeneChip microarray after 30 days of consecutive exposure to manual metal arc welding combined with stainless-steel (MMA-SS) welding fumes, and again after 30 days of recovery from MMA-SS fume exposure. In total, 577 genes were identified as being either up-regulated or down-regulated (over twofold changes, p < 0.05) in the lungs of low-dose or high-dose groups. Differentially expressed genes were classified based on a k-means clustering algorithm and biological functions and molecular networks were further analyzed using Ingenuity Pathways Analysis. Among the genes affected by exposure to or recovery from MMA-SS fumes, the transcriptional changes of 13 genes that were highly altered by treatment were confirmed by quantitative real-time PCR. Notably, Mmp12, Cd5l, Ccl7, Cxcl5, and Spp1 related to the immune response were up-regulated only in the exposure group, whereas Trem2, IgG-2a, Igh-1a, and Igh were persistently up-regulated in both the exposure and recovery groups. In addition, several genes that might play a role in the repair process of the lung were up-regulated exclusively in the recovery group. Collectively, these data may help elucidate the molecular mechanism of the recovery process of the lung after welding fume exposure.

  20. A mechanistic model for the superglue fuming of latent fingerprints.

    PubMed

    Czekanski, Patrick; Fasola, Michael; Allison, John

    2006-11-01

    The use of superglue vapors to detect latent fingerprints, known as superglue fuming, is a chemical process that has not been fully described. The role of the fingerprint material in the process, leading to formation of methyl cyanoacrylate polymer at the site of the fingerprint, remains to be established. Films of liquid alkanes respond similarly to actual fingerprints in the fuming experiment. Their responses depended on the hydrocarbon used, viscosity, and film thickness. Aspects such as film thickness appear to be relevant for actual fingerprints as well. A model was proposed in light of these observations. The model compares the process with gas chromatography, in which molecules partition between the gas phase and a stationary phase. Aspects such as accumulation of superglue monomers by partitioning into a thin film (or wax) are consistent with the preferential response of fingerprints on surfaces relative to the background.

  1. Pulmonary inflammation and tumor induction in lung tumor susceptible A/J and resistant C57BL/6J mice exposed to welding fume

    PubMed Central

    Zeidler-Erdely, Patti C; Kashon, Michael L; Battelli, Lori A; Young, Shih-Houng; Erdely, Aaron; Roberts, Jenny R; Reynolds, Steven H; Antonini, James M

    2008-01-01

    Background Welding fume has been categorized as "possibly carcinogenic" to humans. Our objectives were to characterize the lung response to carcinogenic and non-carcinogenic metal-containing welding fumes and to determine if these fumes caused increased lung tumorigenicity in A/J mice, a lung tumor susceptible strain. We exposed male A/J and C57BL/6J, a lung tumor resistant strain, by pharyngeal aspiration four times (once every 3 days) to 85 μg of gas metal arc-mild steel (GMA-MS), GMA-stainless steel (SS), or manual metal arc-SS (MMA-SS) fume, or to 25.5 μg soluble hexavalent chromium (S-Cr). Shams were exposed to saline vehicle. Bronchoalveolar lavage (BAL) was done at 2, 7, and 28 days post-exposure. For the lung tumor study, gross tumor counts and histopathological changes were assessed in A/J mice at 48 and 78 weeks post-exposure. Results BAL revealed notable strain-dependent differences with regards to the degree and resolution of the inflammatory response after exposure to the fumes. At 48 weeks, carcinogenic metal-containing GMA-SS fume caused the greatest increase in tumor multiplicity and incidence, but this was not different from sham. By 78 weeks, tumor incidence in the GMA-SS group versus sham approached significance (p = 0.057). A significant increase in perivascular/peribronchial lymphoid infiltrates for the GMA-SS group versus sham and an increased persistence of this fume in lung cells compared to the other welding fumes was found. Conclusion The increased persistence of GMA-SS fume in combination with its metal composition may trigger a chronic, but mild, inflammatory state in the lung possibly enhancing tumorigenesis in this susceptible mouse strain. PMID:18778475

  2. Global Metabolomic Profiling Reveals an Association of Metal Fume Exposure and Plasma Unsaturated Fatty Acids

    PubMed Central

    Chang, Chiung-yu; Fan, Tianteng; Su, Li; Chen, Feng; Christiani, David C.

    2013-01-01

    Background Welding-associated air pollutants negatively affect the health of exposed workers; however, their molecular mechanisms in causing disease remain largely unclear. Few studies have systematically investigated the systemic toxic effects of welding fumes on humans. Objectives To explore the effects of welding fumes on the plasma metabolome, and to identify biomarkers for risk assessment of welding fume exposure. Methods The two-stage, self-controlled exploratory study included 11 boilermakers from a 2011 discovery panel and 8 boilermakers from a 2012 validation panel. Plasma samples were collected pre- and post-welding fume exposure and analyzed by chromatography/mass spectrometry. Results Eicosapentaenoic or docosapentaenoic acid metabolic changes post-welding were significantly associated with particulate (PM2.5) exposure (p<0.05). The combined analysis by linear mixed-effects model showed that exposure was associated with a statistically significant decline in metabolite change of eicosapentaenoic acid [(95% CI) = −0.013(−0.022∼−0.004); p = 0.005], docosapentaenoic acid n3 [(95% CI) = −0.010(−0.018∼−0.002); p = 0.017], and docosapentaenoic acid n6 [(95% CI) = −0.007(−0.013∼−0.001); p = 0.021]. Pathway analysis identified an association of the unsaturated fatty acid pathway with exposure (p Study−2011 = 0.025; p Study−2012 = 0.021; p Combined = 0.009). The functional network built by these fatty acids and their interactive genes contained significant enrichment of genes associated with various diseases, including neoplasms, cardiovascular diseases, and lipid metabolism disorders. Conclusions High-dose exposure of metal welding fumes decreases unsaturated fatty acids with an exposure-response relationship. This alteration in fatty acids is a potential biological mediator and biomarker for exposure-related health disorders. PMID:24143234

  3. Altered ion transport in normal human bronchial epithelial cells following exposure to chemically distinct metal welding fume particles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fedan, Jeffrey S., E-mail: jsf2@cdc.gov; Thompson,

    Welding fume inhalation causes pulmonary toxicity, including susceptibility to infection. We hypothesized that airway epithelial ion transport is a target of fume toxicity, and investigated the effects of fume particulates from manual metal arc-stainless steel (MMA-SS) and gas metal arc-mild steel (GMA-MS) on ion transport in normal human bronchial epithelium (NHBE) cultured in air-interface. MMA-SS particles, more soluble than GMA-MS particles, contain Cr, Ni, Fe and Mn; GMA-MS particles contain Fe and Mn. MMA-SS or GMA-MS particles (0.0167–166.7 μg/cm{sup 2}) were applied apically to NHBEs. After 18 h transepithelial potential difference (V{sub t}), resistance (R{sub t}), and short circuit currentmore » (I{sub sc}) were measured. Particle effects on Na{sup +} and Cl¯ channels and the Na{sup +},K{sup +},2Cl¯-cotransporter were evaluated using amiloride (apical), 5-nitro-2-[(3-phenylpropyl)amino]benzoic acid (NPPB, apical), and bumetanide (basolateral), respectively. MMA-SS (0.0167–16.7 μg/cm{sup 2}) increased basal V{sub t}. Only 16.7 μg/cm{sup 2} GMA-MS increased basal V{sub t} significantly. MMA-SS or GMA-MS exposure potentiated I{sub sc} responses (decreases) to amiloride and bumetanide, while not affecting those to NPPB, GMA-MS to a lesser degree than MMA-SS. Variable effects on R{sub t} were observed in response to amiloride, and bumetanide. Generally, MMA-SS was more potent in altering responses to amiloride and bumetanide than GMA-MS. Hyperpolarization occurred in the absence of LDH release, but decreases in V{sub t}, R{sub t}, and I{sub sc} at higher fume particulate doses accompanied LDH release, to a greater extent for MMA-SS. Thus, Na{sup +} transport and Na{sup +},K{sup +},2Cl¯-cotransport are affected by fume exposure; MMA-MS is more potent than GMA-MS. Enhanced Na{sup +} absorption and decreased airway surface liquid could compromise defenses against infection. - Highlights: • Welding fume particle toxicity was investigated in human

  4. The particle size distribution, density, and specific surface area of welding fumes from SMAW and GMAW mild and stainless steel consumables.

    PubMed

    Hewett, P

    1995-02-01

    Particle size distributions were measured for fumes from mild steel (MS) and stainless steel (SS); shielded metal arc welding (SMAW) and gas metal arc welding (GMAW) consumables. Up to six samples of each type of fume were collected in a test chamber using a micro-orifice uniform deposit (cascade) impactor. Bulk samples were collected for bulk fume density and specific surface area analysis. Additional impactor samples were collected using polycarbonate substrates and analyzed for elemental content. The parameters of the underlying mass distributions were estimated using a nonlinear least squares analysis method that fits a smooth curve to the mass fraction distribution histograms of all samples for each type of fume. The mass distributions for all four consumables were unimodal and well described by a lognormal distribution; with the exception of the GMAW-MS and GMAW-SS comparison, they were statistically different. The estimated mass distribution geometric means for the SMAW-MS and SMAW-SS consumables were 0.59 and 0.46 micron aerodynamic equivalent diameter (AED), respectively, and 0.25 micron AED for both the GMAW-MS and GMAW-SS consumables. The bulk fume densities and specific surface areas were similar for the SMAW-MS and SMAW-SS consumables and for the GMAW-MS and GMAW-SS consumables, but differed between SMAW and GMAW. The distribution of metals was similar to the mass distributions. Particle size distributions and physical properties of the fumes were considerably different when categorized by welding method. Within each welding method there was little difference between MS and SS fumes.

  5. Capture efficiency of cooking-related fine and ultrafine particles by residential exhaust hoods.

    PubMed

    Lunden, M M; Delp, W W; Singer, B C

    2015-02-01

    Effective exhaust hoods can mitigate the indoor air quality impacts of pollutant emissions from residential cooking. This study reports capture efficiencies (CE) measured for cooking-generated particles for scripted cooking procedures in a 121-m3 chamber with kitchenette. CEs also were measured for burner produced CO2 during cooking and separately for pots and pans containing water. The study used four exhaust hoods previously tested by Delp and Singer (Environ. Sci. Technol., 2012, 46, 6167-6173). For pan-frying a hamburger over medium heat on the back burner, CEs for particles were similar to those for burner produced CO2 and mostly above 80%. For stir-frying green beans in a wok (high heat, front burner), CEs for burner CO2 during cooking varied by hood and airflow: CEs were 34-38% for low (51-68 l/s) and 54-72% for high (109-138 l/s) settings. CEs for 0.3-2.0 μm particles during front burner stir-frying were 3-11% on low and 16-70% on high settings. Results indicate that CEs measured for burner CO2 are not predictive of CEs of cooking-generated particles under all conditions, but they may be suitable to identify devices with CEs above 80% both for burner combustion products and for cooking-related particles. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.

  6. Summary of retrospective asbestos and welding fume exposure estimates for a nuclear naval shipyard and their correlation with radiation exposure estimates.

    PubMed

    Zaebst, D D; Seel, E A; Yiin, J H; Nowlin, S J; Chen, P

    2009-07-01

    In support of a nested case-control study at a U.S. naval shipyard, the results of the reconstruction of historical exposures were summarized, and an analysis was undertaken to determine the impact of historical exposures to potential chemical confounders. The nested case-control study (N = 4388) primarily assessed the relationship between lung cancer and external ionizing radiation. Chemical confounders considered important were asbestos and welding fume (as iron oxide fume), and the chromium and nickel content of welding fume. Exposures to the potential confounders were estimated by an expert panel based on a set of quantitatively defined categories of exposure. Distributions of the estimated exposures and trends in exposures over time were examined for the study population. Scatter plots and Spearman rank correlation coefficients were used to assess the degree of association between the estimates of exposure to asbestos, welding fume, and ionizing radiation. Correlation coefficients were calculated separately for 0-, 15-, 20-, and 25-year time-lagged cumulative exposures, total radiation dose (which included medical X-ray dose) and occupational radiation dose. Exposed workers' estimated cumulative exposures to asbestos ranged from 0.01 fiber-days/cm(3) to just under 20,000 fiber-days/cm(3), with a median of 29.0 fiber-days/cm(3). Estimated cumulative exposures to welding fume ranged from 0.16 mg-days/m(3) to just over 30,000 mg-days/m(3), with a median of 603 mg-days/m(3). Spearman correlation coefficients between cumulative radiation dose and cumulative asbestos exposures ranged from 0.09 (occupational dose) to 0.47 (total radiation dose), and those between radiation and welding fume from 0.14 to 0.47. The estimates of relative risk for ionizing radiation and lung cancer were unchanged when lowest and highest estimates of asbestos and welding fume were considered. These results suggest a fairly large proportion of study population workers were exposed to

  7. Mutagenicity of fume particles from metal arc welding on stainless steel in the Salmonella/microsome test.

    PubMed

    Maxild, J; Andersen, M; Kiel, P

    1978-01-01

    Mutagenic activity of fume particles produced by metal arc welding on stainless steel (ss) is demonstrated by using the Salmonella/microsome mutagenicity test described by Ames et al., with strain TA100 (base-pair substitution) and TA98 (frame-shift reversion). Results of a representative but limited selection of processes and materials show that mutagenic activity is a function of process and process parameters. Welding on stainless steel produces particles that are mutagenic, whereas welding on mild steel (ms) produces particles that are not. Manual metal arc (MMA) welding on stainless steel produces particles of higher mutagenic activity than does metal inert gas (MIG) welding, and fume particles produced by MIG welding under short-arc transfer. Further studies of welding fumes (both particles and gases) must be performed to determine process parameters of significance for the mutagenic activity.

  8. Feasibility of mobile health game "Fume" in supporting tobacco-related health literacy among early adolescents: A three-armed cluster randomized design.

    PubMed

    Parisod, Heidi; Pakarinen, Anni; Axelin, Anna; Löyttyniemi, Eliisa; Smed, Jouni; Salanterä, Sanna

    2018-05-01

    New interventions supporting health literacy and a tobacco-free lifestyle in adolescence are needed to narrow the widening gap in existing health inequalities. Health games offer potential and could be utilized for example in school healthcare, but more research is needed to increase the understanding of the effects of game elements in health interventions. The aim of this feasibility study is to determine the short-term effectiveness of the tobacco-related mobile health game Fume and a non-gamified website in comparison with a no-intervention control group, regarding tobacco-related health literacy among 10-13-year-old early adolescents. In addition, we compare the demand for and acceptability of Fume to that of the website. In total, 151 early adolescents participated in this single-blinded, three-armed cluster randomized trial. The participants from three municipalities in southwest Finland were randomly allocated between a group with access to the health game Fume (n = 61), a group with access to the website (n = 47), and a group with no intervention (n = 43). The intervention groups first participated in a 20-min training session with Fume/the website, and then had two weeks to use Fume/the website based on their own interest. Short-term effectiveness was measured by primary (anti-smoking self-efficacy) and secondary (smoking outcome expectations, attitudes towards tobacco use, tobacco-use motives, motivation to decline tobacco use in the future, and knowledge about tobacco) outcomes derived from the theory-based determinants of tobacco-related health literacy and evaluated with self-assessment questionnaires at baseline and post-intervention (after a two-week follow-up). For evaluating the demand, the actual use of Fume/the website was tracked during the two-week period. Regarding acceptability, the raised interest towards Fume/the website and opinions about the interventions were evaluated post-intervention. Differences were tested with the Mc

  9. Effect of silica fume on the characterization of the geopolymer materials

    NASA Astrophysics Data System (ADS)

    Khater, Hisham M.

    2013-12-01

    The influence of silica fume (SF) addition on properties of geopolymer materials produced from alkaline activation of alumino-silicates metakaolin and waste concrete produced from demolition works has been studied through the measurement of compressive strength, Fourier transform infrared spectroscopy, X-ray diffraction, and scanning electron microscopy (SEM) analysis. Alumino-silicate materials are coarse aggregate included waste concrete and fired kaolin (metakaolin) at 800°C for 3 h, both passing a sieve of 90 μm. Mix specimens containing silica fume were prepared at water/binder ratios in a range of 0.30 under water curing. The used activators are an equal mix of sodium hydroxide and silicate in the ratio of 3:3 wt.%. The control geopolymer mix is composed of metakaolin and waste concrete in an equal mix (50:50, wt.%). Waste concrete was partially replaced by silica fume by 1 to 10 wt.%. The results indicated that compressive strengths of geopolymer mixes incorporating SF increased up to 7% substitution and then decreased up to 10% but still higher than that of the control mix. Results indicated that compressive strengths of geopolymer mixes incorporating SF increases up to 7% substitution and then decreases up to 10% but still higher than the control mix, where 7% SF-digested calcium hydroxide (CH) crystals, decreased the orientation of CH crystals, reduced the crystal size of CH gathered at the interface, and improved the interface more effectively.

  10. Preliminary Geologic Map of the Mount Hood 30- by 60-minute Quadrangle, Northern Cascade Range, Oregon

    USGS Publications Warehouse

    Sherrod, David R.; Scott, William E.

    1995-01-01

    This map shows the geology of the central and eastern parts of the Cascade Range in northern Oregon. The Quaternary andesitic stratovolcano of Mount Hood dominates the northwest quarter of the quadrangle, but nearly the entire area is underlain by arc-related volcanic and volcaniclastic rocks of the Cascade Range. Most stratigraphic units were emplaced since middle Miocene time, and all are Oligocene or younger. Despite the proximity of the map area to the Portland metropolitan area, large parts remained virtually unstudied or known only from limited reconnaissance until the late 1970s. A notable exception is the area surrounding Mount Hood, where mapping and chemical analyses by Wise (1969) provided a framework for geologic interpretation. Mapping since 1975 was conducted first to understand the stratigraphy and structure of the Columbia River Basalt Group (Anderson, 1978; Vogt, 1981; J.L. Anderson, in Swanson and others, 1981; Vandiver-Powell, 1978; Burck, 1986) and later to examine the geothermal potential of Mount Hood (Priest and others, 1982). Additional mapping was completed in 1985 for a geologic map of the Cascade Range in Oregon (Sherrod and Smith, 1989). From 1987 to 1990, detailed mapping was conducted in three 15-minute quadrangles on a limited basis (D.R. Sherrod, unpublished mapping) (see fig. 1 for index to mapping). An ongoing volcanic hazards study of Mount Hood by the U.S. Geological Survey (Scott and others, 1994) has provided the catalyst for completing the geologic map of the Mount Hood 30-minute by 60-minute quadrangle. As of June 1994, only two broad areas still remain largely unmapped. One of these areas, labeled 'unmapped' on the geologic map, lies in the Salmon River valley south of Zigzag along the west margin of the quadrangle. Although strata of the Columbia River Basalt Group in the Salmon River valley were mapped in detail by Burck (1986), the overlying middle and upper(?) Miocene lava flows, volcaniclastic strata, and intrusions

  11. Occupational exposure to manganese-containing welding fumes and pulmonary function indices among natural gas transmission pipeline welders.

    PubMed

    Hassani, Hamid; Golbabaei, Farideh; Ghahri, Asghar; Hosseini, Mostafa; Shirkhanloo, Hamid; Dinari, Behnam; Eskandari, Davood; Fallahi, Majid

    2012-01-01

    The objectives of this study were to evaluate manganese (Mn)-containing welding fumes' exposure, assess urinary Mn as a biomarker for Mn exposure and investigate the correlation of Mn in air, total fumes and urinary Mn with pulmonary function indices in 118 welders and 37 unexposed controls from two regions in Iran, Assaluyeh and Borujen. Air samples were collected on mixed cellulose ester membrane filters in personal air samplers and then analyzed using inductively coupled plasma atomic emission spectroscopy (ICP-AES) (NIOSH Method 7300). For all participants, urine samples were collected during the entire work shift, and Mn in urine was determined by graphite furnace atomic absorption spectroscopy according to NIOSH Method 8310. Spirometric measurements were also done for participants. The maximum exposures to airborne Mn and total fumes were 0.304 ± 0.256 mg/m(3) and 21.52 ± 9.40 mg/m(3), respectively. The urine Mn levels in the various groups ranged between 0.77 to 7.58 μg/l. The correlation between airborne Mn and urinary Mn was significant for total whole participants. Some values of spirometric indices were statistically lower in welders rather than controls. Our results indicate that many welders have been exposed to higher concentrations of Mn-containing welding fumes. Urinary Mn can be used as a biomarker for Mn exposure. There were weak inverse correlations between Mn-containing welding fumes and pulmonary function indices, and the inverse correlation between urinary Mn with forced vital capacities (FVC) and forced expiratory volume in 1 s (FEV1) was significant.

  12. Ventilation of Welding Fumes in Vocational Agriculture Laboratories in Missouri.

    ERIC Educational Resources Information Center

    Carr, Brenda; And Others

    1982-01-01

    This study was intended to measure the effectiveness of ventilation systems in removing airborne contaminants produced by arc welding in vocational agriculture laboratories in Missouri. It was found that most schools did not meet the minimum Occupational Safety and Health Administration standards. (SK)

  13. Profiling stainless steel welding processes to reduce fume emissions, hexavalent chromium emissions and operating costs in the workplace

    PubMed Central

    Keane, Michael; Siert, Arlen; Stone, Samuel; Chen, Bean T.

    2016-01-01

    Nine gas metal arc welding (GMAW) processes for stainless steel were assessed for fume generation rates, fume generation rates per g of electrode consumed, and emission rates for hexavalent chromium (Cr6+). Elemental manganese, nickel, chromium, iron emissions per unit length of weld and labor plus consumables costs were similarly measured. Flux-cored arc welding and shielded metal arc (SMAW) processes were also studied. The objective was to identify the best welding processes for reducing workplace exposures, and estimate costs for all processes. Using a conical chamber, fumes were collected, weighed, recovered and analyzed by inductively-coupled atomic emission spectroscopy for metals, and by ion chromatography for Cr6+. GMAW processes used were Surface Tension Transfer™, Regulated Metal Deposition™, Cold Metal Transfer™, short-circuit, axial spray, and pulsed spray modes. Flux-cored welding used gas shielding; SMAW used E308 rods. Costs were estimated as dollars per m length of a ¼ in (6.3 mm) thick horizontal butt weld; equipment costs were estimated as ratios of new equipment costs to a 250 ampere capacity SMAW welding machine. Results indicate a broad range of fume emission factors for the processes studied. Fume emission rates per g of electrode were lowest for GMAW processes such as pulsed-spray mode (0.2 mg/g), and highest for SMAW (8 mg fume/g electrode). Emission rates of Cr6+ ranged from 50 to 7800 μg/min, and Cr6+ generation rates per g electrode ranged from 1 to 270μg/g. Elemental Cr generation rates spanned 13 to 330μg/g. Manganese emission rates ranged from 50 to 300μg/g. Nickel emission rates ranged from 4 to140 μg/g. Labor and consumables costs ranged from $3.15 (GMAW pulsed spray) to $7.40 (SMAW) per meter of finished weld, and were measured or estimated for all 11 processes tested. Equipment costs for some processes may be as much as 5 times the cost of a typical SMAW welding machine. The results show that all of the GMAW processes

  14. Profiling stainless steel welding processes to reduce fume emissions, hexavalent chromium emissions and operating costs in the workplace.

    PubMed

    Keane, Michael; Siert, Arlen; Stone, Samuel; Chen, Bean T

    2016-01-01

    Nine gas metal arc welding (GMAW) processes for stainless steel were assessed for fume generation rates, fume generation rates per g of electrode consumed, and emission rates for hexavalent chromium (Cr(6+)). Elemental manganese, nickel, chromium, iron emissions per unit length of weld, and labor plus consumables costs were similarly measured. Flux-cored arc welding and shielded metal arc (SMAW) processes were also studied. The objective was to identify the best welding processes for reducing workplace exposures, and estimate costs for all processes. Using a conical chamber, fumes were collected, weighed, recovered, and analyzed by inductively coupled atomic emission spectroscopy for metals, and by ion chromatography for Cr(6+). GMAW processes used were Surface Tension Transfer, Regulated Metal Deposition, Cold Metal Transfer, short-circuit, axial spray, and pulsed spray modes. Flux-cored welding used gas shielding; SMAW used E308 rods. Costs were estimated as dollars per m length of a ¼ in (6.3 mm) thick horizontal butt weld; equipment costs were estimated as ratios of new equipment costs to a 250 ampere capacity SMAW welding machine. Results indicate a broad range of fume emission factors for the processes studied. Fume emission rates per g of electrode were lowest for GMAW processes such as pulsed-spray mode (0.2 mg/g), and highest for SMAW (8 mg fume/g electrode). Emission rates of Cr(6+) ranged from 50-7800 µg/min, and Cr(6+) generation rates per g electrode ranged from 1-270 µg/g. Elemental Cr generation rates spanned 13-330 µg/g. Manganese emission rates ranged from 50-300 µg/g. Nickel emission rates ranged from 4-140 µg/g. Labor and consumables costs ranged from $3.15 (GMAW pulsed spray) to $7.40 (SMAW) per meter of finished weld, and were measured or estimated for all 11 processes tested. Equipment costs for some processes may be as much as five times the cost of a typical SMAW welding machine. The results show that all of the GMAW processes in this

  15. Optimum mixture proportions for concretes containing fly ash and silica fume.

    DOT National Transportation Integrated Search

    1991-01-01

    Concretes with equal water/cement ratios and equal paste volumes of various combinations of cement, fly ash, and silica fume were tested to establish parameters for strength and chloride permeability. Comparative specimens with Type II and Type III c...

  16. Exposure to welding fumes increases lung cancer risk among light smokers but not among heavy smokers: evidence from two case-control studies in Montreal.

    PubMed

    Vallières, Eric; Pintos, Javier; Lavoué, Jérôme; Parent, Marie-Élise; Rachet, Bernard; Siemiatycki, Jack

    2012-08-01

    We investigated relationships between occupational exposure to gas and arc welding fumes and the risk of lung cancer among workers exposed to these agents throughout the spectrum of industries. Two population-based case-control studies were conducted in Montreal. Study I (1979-1986) included 857 cases and 1066 controls, and Study II (1996-2001) comprised 736 cases and 894 controls. Detailed job histories were obtained by interview and evaluated by an expert team of chemist-hygienists to estimate degree of exposure to approximately 300 substances for each job. Gas and arc welding fumes were among the agents evaluated. We estimated odds ratios (ORs) and 95% confidence intervals (CIs) of lung cancer using logistic regression, adjusting for smoking history and other covariates. The two studies provided similar results, so a pooled analysis was conducted. Among all subjects, no significant association was found between lung cancer and gas welding fumes (OR = 1.1; 95% CI = 0.9-1.4) or arc welding fumes (OR = 1.0; 95% CI = 0.8-1.2). However, when restricting attention to light smokers, there was an increased risk of lung cancer in relation to gas welding fumes (OR = 2.9; 95% CI = 1.7-4.8) and arc welding fumes (OR = 2.3; 95% CI = 1.3-3.8), with even higher OR estimates among workers with the highest cumulative exposures. In conclusion, there was no detectable excess risk of lung cancer due to welding fumes among moderate to heavy smokers; but among light smokers we found an excess risk related to both types of welding fumes.

  17. Increase in oxidative stress levels following welding fume inhalation: a controlled human exposure study.

    PubMed

    Graczyk, Halshka; Lewinski, Nastassja; Zhao, Jiayuan; Sauvain, Jean-Jacques; Suarez, Guillaume; Wild, Pascal; Danuser, Brigitta; Riediker, Michael

    2016-06-10

    Tungsten inert gas (TIG) welding represents one of the most widely used metal joining processes in industry. It has been shown to generate a large majority of particles at the nanoscale and to have low mass emission rates when compared to other types of welding. Despite evidence that TIG fume particles may produce reactive oxygen species (ROS), limited data is available for the time course changes of particle-associated oxidative stress in exposed TIG welders. Twenty non-smoking male welding apprentices were exposed to TIG welding fumes for 60 min under controlled, well-ventilated settings. Exhaled breathe condensate (EBC), blood and urine were collected before exposure, immediately after exposure, 1 h and 3 h post exposure. Volunteers participated in a control day to account for oxidative stress fluctuations due to circadian rhythm. Biological liquids were assessed for total reducing capacity, hydrogen peroxide (H2O2), malondialdehyde (MDA), and 8-hydroxy-2'-deoxyguanosine (8-OHdG) concentrations at each time point. A linear mixed model was used to assess within day and between day differences. Significant increases in the measured biomarkers were found at 3 h post exposure. At 3 h post exposure, we found a 24 % increase in plasma-H2O2 concentrations ([95%CI: 4 % to 46 %], p = 0.01); a 91 % increase in urinary-H2O2 ([2 % to 258 %], p = 0.04); a 14 % increase in plasma-8-OHdG ([0 % to 31 %], p = 0.049); and a 45 % increase in urinary-8-OHdG ([3 % to 105 %], p = 0.03). Doubling particle number concentration (PNC) exposure was associated with a 22 % increase of plasma-8-OHdG at 3 h post exposure (p = 0.01). A 60-min exposure to TIG welding fume in a controlled, well-ventilated setting induced acute oxidative stress at 3 h post exposure in healthy, non-smoking apprentice welders not chronically exposed to welding fumes. As mass concentration of TIG welding fume particles is very low when compared to other types of welding, it is

  18. Recovery from welding-fume-exposure-induced lung fibrosis and pulmonary function changes in sprague dawley rats.

    PubMed

    Sung, Jae Hyuck; Choi, Byung-Gil; Maeng, Seung-Hee; Kim, Soo-Jin; Chung, Yong Hyun; Han, Jeong Hee; Song, Kyung Seuk; Lee, Yong Hwan; Cho, Yong Bong; Cho, Myung-Haing; Kim, Kwang Jong; Hyun, Jin Suk; Yu, Il Je

    2004-12-01

    Welder's pneumoconiosis has generally been determined as benign based on the absence of pulmonary function abnormalities in welders with marked radiographic abnormalities. Yet, there have also been several reports on welders with respiratory symptoms, indicating lung function impairment, X-ray abnormalities, and extensive fibrosis. Accordingly, this study attempted to investigate the inflammatory responses and pulmonary function changes in rats during a 60-day welding-fume-inhalation exposure period to elucidate the process of fibrosis. The rats were exposed to manual metal-arc stainless-steel welding fumes (MMA-SS) with total suspended particulate concentrations of 64.8 +/- 0.9 (low dose) and 107.8 +/- 2.6 mg/m3 (high dose) for 2 h per day in an inhalation chamber for 60 days. Animals were sacrificed after the initial 2-h exposure and after 15, 30, and 60 days, and the pulmonary function was also measured every week after the daily exposure. Elevated cellular differential counts were also measured in the acellular bronchoalveolar lavage fluid of the rats exposed to the MMA-SS fumes for 60 days. Among the pulmonary function test parameters, only the tidal volume showed a statistically significant and dose-dependent decrease after 35 to 60 days of MMA-SS welding-fume exposure. When the rats exposed to the welding fumes were left for 60 days to recover their lung function and cellular differentiation, recovery was observed in both the high and low-dose rats exposed up to 30 days, resulting in the disappearance of inflammatory cells and restoration of the tidal volume. The rats exposed for 60 days at the low dose also recovered from the inflammation and tidal volume loss, yet the rats exposed for 60 days at the high dose did not fully recover even after a 60-day recovery period. Therefore, when taken together, the results of the current study suggest that a decrease in the tidal volume could be used as an early indicator of pulmonary fibrosis induced by welding-fume

  19. Post-Decontamination Vapor Sampling and Analytical Test Methods

    DTIC Science & Technology

    2015-08-12

    construction materials (e.g., acrylic, stainless steel , glass, etc.) for containing the chemical contaminants, coupons, coupon holders, and decontaminant(s...made of inert materials, e.g., stainless steel , T6061 aluminum, or equivalent. The construction material may be treated to further minimize...include glove ports. The chamber may have certified fume hoods for the containment of toxic chemicals. All exhaust air must be filtered to

  20. Carbon Dioxide Exposure Resulting From Hood Protective Equipment Used in Joint Arthroplasty Surgery.

    PubMed

    Patel, Suhani; Fine, Janelle M; Lim, Michael J; Copp, Steven N; Rosen, Adam S; West, John B; Prisk, G Kim

    2017-08-01

    To protect both the surgeon and patient during procedures, hooded protection shields are used during joint arthroplasty procedures. Headache, malaise, and dizziness, consistent with increased carbon dioxide (CO 2 ) exposure, have been anecdotally reported by surgeons using hoods. We hypothesized that increased CO 2 concentrations were causing reported symptoms. Six healthy subjects (4 men) donned hooded protection, fan at the highest setting. Arm cycle ergometry at workloads of 12 and 25 watts (W) simulated workloads encountered during arthroplasty. Inspired O 2 and CO 2 concentrations at the nares were continuously measured at rest, 12 W, and 25 W. At each activity level, the fan was deactivated and the times for CO 2 to reach 0.5% and 1.0% were measured. At rest, inspired CO 2 was 0.14% ± 0.04%. Exercise had significant effect on CO 2 compared with rest (0.26% ± 0.08% at 12 W, P = .04; 0.31% ± 0.05% at 25 W, P = .003). Inspired CO 2 concentration increased rapidly with fan deactivation, with the time for CO 2 to increase to 0.5% and 1.0% after fan deactivation being rapid but variable (0.5%, 12 ± 9 seconds; 1%, 26 ± 15 seconds). Time for CO 2 to return below 0.5% after fan reactivation was 20 ± 37 seconds. During simulated joint arthroplasty, CO 2 remained within Occupational Safety and Health Administration (OSHA) standards with the fan at the highest setting. With fan deactivation, CO 2 concentration rapidly exceeds OSHA standards. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. New Whole-House Solutions Case Study: Hood River Passive House

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2014-02-01

    The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to "reduce home energy use by 30%-50%" (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift Housemore » and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.« less

  2. 2. In the foreground is the fan which removed fumes ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. In the foreground is the fan which removed fumes from the galvanizing area in building #8. In the background are the waste treatment tanks for the acids and alkali used in the zinc-electro-plating process. - American Chain & Cable Company, East Princess Street (400 Block), York, York County, PA

  3. Gene-expression profiling using suppression-subtractive hybridization and cDNA microarray in rat mononuclear cells in response to welding-fume exposure.

    PubMed

    Rim, Kyung Taek; Park, Kun Koo; Sung, Jae Hyuck; Chung, Yong Hyun; Han, Jeong Hee; Cho, Key Seung; Kim, Kwang Jong; Yu, Il Je

    2004-06-01

    Welders with radiographic pneumoconiosis abnormalities have shown a gradual clearing of the X-ray identified effects following removal from exposure. In some cases, the pulmonary fibrosis associated with welding fumes appears in a more severe form in welders. Accordingly, for the early detection of welding-fume-exposure-induced pulmonary fibrosis, the gene expression profiles of peripheral mononuclear cells from rats exposed to welding fumes were studied using suppression-subtractive hybridization (SSH) and a cDNA microarray. As such, Sprague-Dawley rats were exposed to a stainless steel arc welding fume for 2 h/day in an inhalation chamber with a 1107.5 +/- 2.6 mg/m3 concentration of total suspended particulate (TSP) for 30 days. Thereafter, the total RNA was extracted from the peripheral blood mononuclear cells, the cDNA synthesized from the total RNA using the SMART PCR cDNA method, and SSH performed to select the welding-fume-exposure-regulated genes. The cDNAs identified by the SSH were then cloned into a plasmid miniprep, sequenced and the sequences analysed using the NCBI BLAST programme. In the SSH cloned cDNA microarray analysis, five genes were found to increase their expression by 1.9-fold or more, including Rgs 14, which plays an important function in cellular signal transduction pathways; meanwhile 36 genes remained the same and 30 genes decreased their expression by more than 59%, including genes associated with the immune response, transcription factors and tyrosine kinases. Among the 5200 genes analysed, 256 genes (5.1%) were found to increase their gene expression, while 742 genes (15%) decreased their gene expression in response to the welding-fume exposure when tested using a commercial 5.0k DNA microarray. Therefore, unlike exposure to other toxic substances, prolonged welding-fume exposure was found to substantially downregulate many genes.

  4. Safety in laboratories: Indian scenario.

    PubMed

    Mustafa, Ajaz; Farooq, A Jan; Qadri, Gj; S A, Tabish

    2008-07-01

    Health and safety in clinical laboratories is becoming an increasingly important subject as a result of emergence of highly infectious diseases such as Hepatitis and HIV. A cross sectional study was carried out to study the safety measures being adopted in clinical laboratories of India. Heads of laboratories of teaching hospitals of India were subjected to a standardized, pretested questionnaire. Response rate was 44.8%. only 60% of laboratories had person in-charge of safety in laboratory. Seventy three percent of laboratories had safety education program regarding hazards. In 91% of laboratories staff is using protective clothing while working in laboratories. Hazardous material regulations are followed in 78% of laboratories. Regular health check ups are carried among laboratory staff in 43.4% of laboratories.Safety manual is available in 56.5% of laboratories. 73.9% of laboratories are equipped with fire extinguishers. Fume cupboards are provided in 34.7% of laboratories and they are regularly checked in 87.5% of these laboratories. In 78.26% of laboratories suitable measures are taken to minimize formation of aerosols.In 95.6% of laboratories waste is disposed off as per bio-medical waste management handling rules. Laboratory of one private medical college was accredited with NABL and safety parameters were better in that laboratory. Installing safety engineered devices apparently contributes to significant decrease in injuries in laboratories; laboratory safety has to be a part of overall quality assurance programme in hospitals. Accreditation has to be made necessary for all laboratories.

  5. Study the velocity and pressure exerted in front of the filter surface in the kitchen hood system by using ANSYS

    NASA Astrophysics Data System (ADS)

    Asmuin, Norzelawati; Pairan, M. Rasidi; Isa, Norasikin Mat; Sies, Farid

    2017-04-01

    Commercial kitchen hood ventilation system is a device used to capture and filtered the plumes from cooking activities in the kitchen area. Nowadays, it is very popular in the industrial sector such as restaurant and hotel to provide hygiene food. This study focused at the KSA filter part which installed in the kitchen hood system, the purpose of this study is to identify the critical region which indicated by observing the velocity and pressure of plumes exerted at of KSA filter. It is important to know the critical location of the KSA filter in order to install the nozzle which will helps increase the filtration effectiveness. The ANSYS 16.1 (FLUENT) software as a tool used to simulate the kitchen hood systems which consist of KSA filter. The commercial kitchen hood system model has a dimension 700 mm width, 1600 mm length and 555 mm height. The system has two inlets and one outlet. The velocity of the plumes is set to be 0.235m/s and the velocity of the inlet capture jet is set to be 1.078m/s. The KSA filter is placed 45 degree from the y axis. The result shows the plumes has more tendency flowing pass through at the bottom part of KSA filter.

  6. Ground-water resources in the Hood Basin, Oregon

    USGS Publications Warehouse

    Grady, Stephen J.

    1983-01-01

    The Hood Basin, an area of 1,035 square miles in north-central Oregon, includes the drainage basins of all tributaries of the Columbia River between Eagle Creek and Fifteenmile Creek. The physical characteristics and climate of the basin are diverse. The Wasco subarea, in the eastern half of the basin, has moderate relief, mostly intermittent streams, and semiarid climate. The Hood subarea, in the western half, has rugged topography, numerous perennial streams, and a humid climate.Water-bearing geologic units that underlie the basin include volcanic, volcaniclastic, and sedimentary rocks of Miocene to Holocene age, and unconsolidated surficial deposits of Pleistocene and Holocene age. The most important water-bearing unit, the Columbia River Basalt Group, underlies almost the entire basin. Total thickness probably exceeds 2,000 feet, but by 1980 only the upper 1,000 feet or less had been developed by wells. Wells in this unit generally yield from 15 to 1,000 gallons per minute and a few yield as much as 3,300 gallons per minute.The most productive aquifer in the Columbia River Basalt Group is The Dalles Ground Water Reservoir, a permeable zone of fractured basalt about 25 to 30 square miles in extent that underlies the city of The Dalles. During the late 1950's and mid-1960's, withdrawals of 15,000 acre-feet per year or more caused water levels in the aquifer to decline sharply. Pumpage had diminished to about 5,000 acre-feet per year in 1979 and water levels have stabilized, indicating that ground water recharge and discharge, including the pumping, are in balance.The other principal geologic units in the basin have more limited areal distribution and less saturated thickness than the Columbia River Basalt Group. Generally, these units are capable of yielding from a few to a hundred gallons per minute to wells.Most of the ground water in the basin is chemically suitable for domestic, irrigation, or other uses. Some ground water has objectionable concentrations of

  7. How the Cobra Got Its Flesh-Eating Venom: Cytotoxicity as a Defensive Innovation and Its Co-Evolution with Hooding, Aposematic Marking, and Spitting

    PubMed Central

    Panagides, Nadya; Jackson, Timothy N.W.; Ikonomopoulou, Maria P.; Arbuckle, Kevin; Pretzler, Rudolf; Yang, Daryl C.; Ali, Syed A.; Koludarov, Ivan; Dobson, James; Sanker, Brittany; Asselin, Angelique; Santana, Renan C.; Hendrikx, Iwan; van der Ploeg, Harold; Tai-A-Pin, Jeremie; van den Bergh, Romilly; Kerkkamp, Harald M.I.; Vonk, Freek J.; Naude, Arno; Strydom, Morné A.; Jacobsz, Louis; Dunstan, Nathan; Jaeger, Marc; Hodgson, Wayne C.; Miles, John; Fry, Bryan G.

    2017-01-01

    The cytotoxicity of the venom of 25 species of Old World elapid snake was tested and compared with the morphological and behavioural adaptations of hooding and spitting. We determined that, contrary to previous assumptions, the venoms of spitting species are not consistently more cytotoxic than those of closely related non-spitting species. While this correlation between spitting and non-spitting was found among African cobras, it was not present among Asian cobras. On the other hand, a consistent positive correlation was observed between cytotoxicity and utilisation of the defensive hooding display that cobras are famous for. Hooding and spitting are widely regarded as defensive adaptations, but it has hitherto been uncertain whether cytotoxicity serves a defensive purpose or is somehow useful in prey subjugation. The results of this study suggest that cytotoxicity evolved primarily as a defensive innovation and that it has co-evolved twice alongside hooding behavior: once in the Hemachatus + Naja and again independently in the king cobras (Ophiophagus). There was a significant increase of cytotoxicity in the Asian Naja linked to the evolution of bold aposematic hood markings, reinforcing the link between hooding and the evolution of defensive cytotoxic venoms. In parallel, lineages with increased cytotoxicity but lacking bold hood patterns evolved aposematic markers in the form of high contrast body banding. The results also indicate that, secondary to the evolution of venom rich in cytotoxins, spitting has evolved three times independently: once within the African Naja, once within the Asian Naja, and once in the Hemachatus genus. The evolution of cytotoxic venom thus appears to facilitate the evolution of defensive spitting behaviour. In contrast, a secondary loss of cytotoxicity and reduction of the hood occurred in the water cobra Naja annulata, which possesses streamlined neurotoxic venom similar to that of other aquatic elapid snakes (e.g., hydrophiine sea

  8. How the Cobra Got Its Flesh-Eating Venom: Cytotoxicity as a Defensive Innovation and Its Co-Evolution with Hooding, Aposematic Marking, and Spitting.

    PubMed

    Panagides, Nadya; Jackson, Timothy N W; Ikonomopoulou, Maria P; Arbuckle, Kevin; Pretzler, Rudolf; Yang, Daryl C; Ali, Syed A; Koludarov, Ivan; Dobson, James; Sanker, Brittany; Asselin, Angelique; Santana, Renan C; Hendrikx, Iwan; van der Ploeg, Harold; Tai-A-Pin, Jeremie; van den Bergh, Romilly; Kerkkamp, Harald M I; Vonk, Freek J; Naude, Arno; Strydom, Morné A; Jacobsz, Louis; Dunstan, Nathan; Jaeger, Marc; Hodgson, Wayne C; Miles, John; Fry, Bryan G

    2017-03-13

    The cytotoxicity of the venom of 25 species of Old World elapid snake was tested and compared with the morphological and behavioural adaptations of hooding and spitting. We determined that, contrary to previous assumptions, the venoms of spitting species are not consistently more cytotoxic than those of closely related non-spitting species. While this correlation between spitting and non-spitting was found among African cobras, it was not present among Asian cobras. On the other hand, a consistent positive correlation was observed between cytotoxicity and utilisation of the defensive hooding display that cobras are famous for. Hooding and spitting are widely regarded as defensive adaptations, but it has hitherto been uncertain whether cytotoxicity serves a defensive purpose or is somehow useful in prey subjugation. The results of this study suggest that cytotoxicity evolved primarily as a defensive innovation and that it has co-evolved twice alongside hooding behavior: once in the Hemachatus + Naja and again independently in the king cobras ( Ophiophagus ). There was a significant increase of cytotoxicity in the Asian Naja linked to the evolution of bold aposematic hood markings, reinforcing the link between hooding and the evolution of defensive cytotoxic venoms. In parallel, lineages with increased cytotoxicity but lacking bold hood patterns evolved aposematic markers in the form of high contrast body banding. The results also indicate that, secondary to the evolution of venom rich in cytotoxins, spitting has evolved three times independently: once within the African Naja , once within the Asian Naja , and once in the Hemachatus genus. The evolution of cytotoxic venom thus appears to facilitate the evolution of defensive spitting behaviour. In contrast, a secondary loss of cytotoxicity and reduction of the hood occurred in the water cobra Naja annulata , which possesses streamlined neurotoxic venom similar to that of other aquatic elapid snakes (e.g., hydrophiine

  9. Physicochemical and toxicological characteristics of welding fume derived particles generated from real time welding processes.

    PubMed

    Chang, Cali; Demokritou, Philip; Shafer, Martin; Christiani, David

    2013-01-01

    Welding fume particles have been well studied in the past; however, most studies have examined welding fumes generated from machine models rather than actual exposures. Furthermore, the link between physicochemical and toxicological properties of welding fume particles has not been well understood. This study aims to investigate the physicochemical properties of particles derived during real time welding processes generated during actual welding processes and to assess the particle size specific toxicological properties. A compact cascade impactor (Harvard CCI) was stationed within the welding booth to sample particles by size. Size fractionated particles were extracted and used for both off-line physicochemical analysis and in vitro cellular toxicological characterization. Each size fraction was analyzed for ions, elemental compositions, and mass concentration. Furthermore, real time optical particle monitors (DustTrak™, TSI Inc., Shoreview, Minn.) were used in the same welding booth to collect real time PM2.5 particle number concentration data. The sampled particles were extracted from the polyurethane foam (PUF) impaction substrates using a previously developed and validated protocol, and used in a cellular assay to assess oxidative stress. By mass, welding aerosols were found to be in coarse (PM 2.5–10), and fine (PM 0.1–2.5) size ranges. Most of the water soluble (WS) metals presented higher concentrations in the coarse size range with some exceptions such as sodium, which presented elevated concentration in the PM 0.1 size range. In vitro data showed size specific dependency, with the fine and ultrafine size ranges having the highest reactive oxygen species (ROS) activity. Additionally, this study suggests a possible correlation between welders' experience, the welding procedure and equipment used and particles generated from welding fumes. Mass concentrations and total metal and water soluble metal concentrations of welding fume particles may be

  10. Bronchocarcinogenic properties of welding and thermal spraying fumes containing chromium in the rat.

    PubMed

    Berg, N O; Berlin, M; Bohgard, M; Rudell, B; Schütz, A; Warvinge, K

    1987-01-01

    The possible bronchocarcinogenic effects of fumes released during the shielded metal arc welding of stainless steel and the thermal spraying of chromium oxide (Cr2O3) have been studied on the rat. The fume particles were shown to contain tri- and hexavalent chromium in soluble and low soluble forms; they were collected and implanted as pellets in the bronchi of groups of 100 rats by the method of Laskin et al. A negative control group of 100 rats was included, as well as positive controls receiving pellets containing benz(a)pyrene. The experiment was continued for 34 months; no differences of biological significance were noted between the growth rates, survival times, and terminal organ weights of the test and negative control groups. At autopsy, the macroscopic and microscopic appearance of the organs in the three groups, including the local reaction to the implanted pellet, were similar. No precancerous changes were observed at the implantation sites; one rat, who received a pellet containing welding fumes, showed squamous cell carcinoma remote from the implantation site and not associated with the bronchus. It had the appearance of a metastasis. All three benz(a)pyrene control rats developed cancer at the implantation site. The occupational health implications of these findings are discussed.

  11. Understanding the chemistry of the development of latent fingerprints by superglue fuming.

    PubMed

    Wargacki, Stephen P; Lewis, Linda A; Dadmun, Mark D

    2007-09-01

    Cyanoacrylate fuming is a widely used forensic tool for the development of latent fingerprints, however the mechanistic details of the reaction between the fingerprint residue and the cyanoacrylate vapor are not well understood. Here the polymerization of ethyl-cyanoacrylate vapor by sodium lactate or alanine solutions, two of the major components in fingerprint residue, has been examined by monitoring the time dependence of the mass uptake and resultant polymer molecular weight characteristics. This data provides insight into the molecular level actions in the efficient development of latent fingerprints by superglue fuming. The results show that the carboxylate moiety is the primary initiator of the polymerization process and that a basic environment inhibits chain termination while an acidic environment promotes it. The results also indicate that water cannot be the primary initiator in this forensic technique.

  12. Exposure to welding fumes increases lung cancer risk among light smokers but not among heavy smokers: evidence from two case–control studies in Montreal

    PubMed Central

    Vallières, Eric; Pintos, Javier; Lavoué, Jérôme; Parent, Marie-Élise; Rachet, Bernard; Siemiatycki, Jack

    2012-01-01

    We investigated relationships between occupational exposure to gas and arc welding fumes and the risk of lung cancer among workers exposed to these agents throughout the spectrum of industries. Two population-based case–control studies were conducted in Montreal. Study I (1979–1986) included 857 cases and 1066 controls, and Study II (1996–2001) comprised 736 cases and 894 controls. Detailed job histories were obtained by interview and evaluated by an expert team of chemist–hygienists to estimate degree of exposure to approximately 300 substances for each job. Gas and arc welding fumes were among the agents evaluated. We estimated odds ratios (ORs) and 95% confidence intervals (CIs) of lung cancer using logistic regression, adjusting for smoking history and other covariates. The two studies provided similar results, so a pooled analysis was conducted. Among all subjects, no significant association was found between lung cancer and gas welding fumes (OR = 1.1; 95% CI = 0.9–1.4) or arc welding fumes (OR = 1.0; 95% CI = 0.8–1.2). However, when restricting attention to light smokers, there was an increased risk of lung cancer in relation to gas welding fumes (OR = 2.9; 95% CI = 1.7–4.8) and arc welding fumes (OR = 2.3; 95% CI = 1.3–3.8), with even higher OR estimates among workers with the highest cumulative exposures. In conclusion, there was no detectable excess risk of lung cancer due to welding fumes among moderate to heavy smokers; but among light smokers we found an excess risk related to both types of welding fumes. PMID:23342253

  13. Heart rate variability, hemostatic and acute inflammatory blood parameters in healthy adults after short-term exposure to welding fume.

    PubMed

    Scharrer, E; Hessel, H; Kronseder, A; Guth, W; Rolinski, B; Jörres, R A; Radon, K; Schierl, R; Angerer, P; Nowak, D

    2007-02-01

    The present study aimed to investigate, whether short-term experimental exposure to high levels of welding fumes would be capable of exerting acute effects in healthy subjects. Specifically, we assessed cardiovascular function in terms of heart rate variability (HRV) as well as the concentrations of inflammatory mediators and hemostatic proteins in blood as outcome measures. Twenty subjects without a history of airway and cardiovascular diseases were exposed to either control air or welding fume for 1 h on 2 separate days under standardized conditions. The median concentration of the alveolar particle fraction during welding was 3.5 mg/m(3 )(quartiles: 1.4-6.3 mg/m(3); range 1.0-25.3 mg/m(3)). Five hours later a panel of clinical assessments was performed, including HRV measurement and drawing of blood samples. There were no changes in symptom ratings or lung function after welding fume exposure. Exposures did also not differ regarding effects on time- and frequency-domain parameters of HRV. Similarly, blood leukocyte numbers, cell differentials and the blood levels of fibrinogen, C-reactive protein, antithrombin III, factor VIII, von Willebrand factor, ristocetin cofactor, sICAM-1, tumor necrosis factor alpha, interleukin 6, interleukin 8 and epithelial neutrophil activating peptide 78 were not altered by welding fume inhalation. However, there was a significant fall in the level of endothelin-1 (P < 0.01). In conclusion, the data did not indicate effects of clinical significance of a short-term high-level exposure to welding fumes on HRV or a set of blood hemostatic and acute inflammatory parameters in healthy subjects. The small but statistically significant effect on endothelin levels demonstrated that measurable effects could be elicited even in these individuals. Overall, welding fumes are not likely to exert acute cardiovascular effects in healthy individuals.

  14. Comparative study on strength properties of cement mortar by partial replacement of cement with ceramic powder and silica fume

    NASA Astrophysics Data System (ADS)

    Himabindu, Ch.; Geethasri, Ch.; Hari, N.

    2018-05-01

    Cement mortar is a mixture of cement and sand. Usage of high amount of cement increases the consumption of natural resources and electric power. To overcome this problem we need to replace cement with some other material. Cement is replaced with many other materials like ceramic powder, silica fume, fly ash, granulated blast furnace slag, metakaolin etc.. In this research cement is replaced with ceramic powder and silica fume. Different combinations of ceramic powder and silica fume in cement were replaced. Cement mortar cubes of 1:3 grade were prepared. These cubes were cured under normal water for 7 days, 14days and 28 days. Compressive strength test was conducted for all mixes of cement mortar cubes.

  15. Kilogram-scale prexasertib monolactate monohydrate synthesis under continuous-flow CGMP conditions.

    PubMed

    Cole, Kevin P; Groh, Jennifer McClary; Johnson, Martin D; Burcham, Christopher L; Campbell, Bradley M; Diseroad, William D; Heller, Michael R; Howell, John R; Kallman, Neil J; Koenig, Thomas M; May, Scott A; Miller, Richard D; Mitchell, David; Myers, David P; Myers, Steven S; Phillips, Joseph L; Polster, Christopher S; White, Timothy D; Cashman, Jim; Hurley, Declan; Moylan, Robert; Sheehan, Paul; Spencer, Richard D; Desmond, Kenneth; Desmond, Paul; Gowran, Olivia

    2017-06-16

    Advances in drug potency and tailored therapeutics are promoting pharmaceutical manufacturing to transition from a traditional batch paradigm to more flexible continuous processing. Here we report the development of a multistep continuous-flow CGMP (current good manufacturing practices) process that produced 24 kilograms of prexasertib monolactate monohydrate suitable for use in human clinical trials. Eight continuous unit operations were conducted to produce the target at roughly 3 kilograms per day using small continuous reactors, extractors, evaporators, crystallizers, and filters in laboratory fume hoods. Success was enabled by advances in chemistry, engineering, analytical science, process modeling, and equipment design. Substantial technical and business drivers were identified, which merited the continuous process. The continuous process afforded improved performance and safety relative to batch processes and also improved containment of a highly potent compound. Copyright © 2017, American Association for the Advancement of Science.

  16. Effect of short-term stainless steel welding fume inhalation exposure on lung inflammation, injury, and defense responses in rats.

    PubMed

    Antonini, James M; Stone, Sam; Roberts, Jenny R; Chen, Bean; Schwegler-Berry, Diane; Afshari, Aliakbar A; Frazer, David G

    2007-09-15

    Many welders have experienced bronchitis, metal fume fever, lung function changes, and an increase in the incidence of lung infection. Questions remain regarding the possible mechanisms associated with the potential pulmonary effects of welding fume exposure. The objective was to assess the early effects of stainless steel (SS) welding fume inhalation on lung injury, inflammation, and defense responses. Male Sprague-Dawley rats were exposed to gas metal arc-SS welding fume at a concentration of 15 or 40 mg/m(3) x 3 h/day for 1, 3, or 10 days. The control group was exposed to filtered air. To assess lung defense responses, some animals were intratracheally inoculated with 5x10(4) Listeria monocytogenes 1 day after the last exposure. Welding particles were collected during exposure, and elemental composition and particle size were determined. At 1, 4, 6, 11, 14, and 30 days after the final exposure, parameters of lung injury (lactate dehydrogenase and albumin) and inflammation (PMN influx) were measured in the bronchoalveolar lavage fluid. In addition, particle-induced effects on pulmonary clearance of bacteria and macrophage function were assessed. SS particles were composed of Fe, Cr, Mn, and Ni. Particle size distribution analysis indicated the mass median aerodynamic diameter of the generated fume to be 0.255 microm. Parameters of lung injury were significantly elevated at all time points post-exposure compared to controls except for 30 days. Interestingly, no significant difference in lung PMNs was observed between the SS and control groups at 1, 4, and 6 days post-exposure. After 6 days post-exposure, a dramatic increase in lung PMNs was observed in the SS group compared to air controls. Lung bacteria clearance and macrophage function were reduced and immune and inflammatory cytokines were altered in the SS group. In summary, short-term exposure of rats to SS welding fume caused significant lung damage and suppressed lung defense responses to bacterial

  17. Effect of short-term stainless steel welding fume inhalation exposure on lung inflammation, injury, and defense responses in rats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Antonini, James M.; Stone, Sam; Roberts, Jenny R.

    Many welders have experienced bronchitis, metal fume fever, lung function changes, and an increase in the incidence of lung infection. Questions remain regarding the possible mechanisms associated with the potential pulmonary effects of welding fume exposure. The objective was to assess the early effects of stainless steel (SS) welding fume inhalation on lung injury, inflammation, and defense responses. Male Sprague-Dawley rats were exposed to gas metal arc-SS welding fume at a concentration of 15 or 40 mg/m{sup 3} x 3 h/day for 1, 3, or 10 days. The control group was exposed to filtered air. To assess lung defense responses,more » some animals were intratracheally inoculated with 5 x 10{sup 4}Listeria monocytogenes 1 day after the last exposure. Welding particles were collected during exposure, and elemental composition and particle size were determined. At 1, 4, 6, 11, 14, and 30 days after the final exposure, parameters of lung injury (lactate dehydrogenase and albumin) and inflammation (PMN influx) were measured in the bronchoalveolar lavage fluid. In addition, particle-induced effects on pulmonary clearance of bacteria and macrophage function were assessed. SS particles were composed of Fe, Cr, Mn, and Ni. Particle size distribution analysis indicated the mass median aerodynamic diameter of the generated fume to be 0.255 {mu}m. Parameters of lung injury were significantly elevated at all time points post-exposure compared to controls except for 30 days. Interestingly, no significant difference in lung PMNs was observed between the SS and control groups at 1, 4, and 6 days post-exposure. After 6 days post-exposure, a dramatic increase in lung PMNs was observed in the SS group compared to air controls. Lung bacteria clearance and macrophage function were reduced and immune and inflammatory cytokines were altered in the SS group. In summary, short-term exposure of rats to SS welding fume caused significant lung damage and suppressed lung defense responses to

  18. Northwest Forest Plan—the first 10 years (1994–2003): socioeconomic monitoring of the Mount Hood National Forest and three local communities.

    Treesearch

    William M. Kay; Ellen M. Donoghue; Susan Charnley; Cassandra. Moseley

    2007-01-01

    This report examines socioeconomic changes that took place between 1990 and 2003 on and around lands managed by the Mount Hood National Forest in Oregon to assess the effects of the Northwest Forest Plan (the Plan) on rural economies and communities there. Three case communities were studied: the Greater Estacada Area, the Upper Hood River Valley, and the Villages of...

  19. MTR WING, TRA604. ONE OF THE LABORATORY UNITS ALONG THE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    MTR WING, TRA-604. ONE OF THE LABORATORY UNITS ALONG THE SOUTH SIDE WALL. NOTE SINK, CABINET, TABLE, AND HOOD UNITS. DUCT ABOVE RECEIVES CONTAMINATED AIR AND SENDS IT TO FAN HOUSE AND STACK. NOTE PARTITION WALL BEHIND WORK UNITS. THE HEALTH PHYSICS LAB WAS SIMILARLY EQUIPPED. WINDOW AT LEFT EDGE OF VIEW. CARD IN LOWER RIGHT WAS INSERTED BY INL PHOTOGRAPHER TO COVER AN OBSOLETE SECURITY RESTRICTION PRINTED ON ORIGINAL NEGATIVE. INL NEGATIVE NO. 4225. Unknown Photographer, 2/13/1952 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  20. Effect of Silica Fume on two-stage Concrete Strength

    NASA Astrophysics Data System (ADS)

    Abdelgader, H. S.; El-Baden, A. S.

    2015-11-01

    Two-stage concrete (TSC) is an innovative concrete that does not require vibration for placing and compaction. TSC is a simple concept; it is made using the same basic constituents as traditional concrete: cement, coarse aggregate, sand and water as well as mineral and chemical admixtures. As its name suggests, it is produced through a two-stage process. Firstly washed coarse aggregate is placed into the formwork in-situ. Later a specifically designed self compacting grout is introduced into the form from the lowest point under gravity pressure to fill the voids, cementing the aggregate into a monolith. The hardened concrete is dense, homogeneous and has in general improved engineering properties and durability. This paper presents the results from a research work attempt to study the effect of silica fume (SF) and superplasticizers admixtures (SP) on compressive and tensile strength of TSC using various combinations of water to cement ratio (w/c) and cement to sand ratio (c/s). Thirty six concrete mixes with different grout constituents were tested. From each mix twenty four standard cylinder samples of size (150mm×300mm) of concrete containing crushed aggregate were produced. The tested samples were made from combinations of w/c equal to: 0.45, 0.55 and 0.85, and three c/s of values: 0.5, 1 and 1.5. Silica fume was added at a dosage of 6% of weight of cement, while superplasticizer was added at a dosage of 2% of cement weight. Results indicated that both tensile and compressive strength of TSC can be statistically derived as a function of w/c and c/s with good correlation coefficients. The basic principle of traditional concrete, which says that an increase in water/cement ratio will lead to a reduction in compressive strength, was shown to hold true for TSC specimens tested. Using a combination of both silica fume and superplasticisers caused a significant increase in strength relative to control mixes.

  1. Hood River PIT-tag interrogation system efficiency study. Annual report of U.S. Geological Survey activities: November 2010-October 2011

    USGS Publications Warehouse

    Jezorek, Ian G.; Connolly, Patrick J.

    2012-01-01

    An additional USGS-CRRL task, under contract number 50150, was to build three antennas for use with Destron-Fearing 2001F-ISO PIT tag readers. These antennas would be 5 used at the East Fork Hood River Acclimation site. They would be placed in the outflow channel to inform managers about the number of PIT tagged steelhead smolts released to the Hood River after a period of acclimation when some mortality and predation might occur. 

  2. Hood River Production Program Monitoring and Evaluation (M&E) - Confederated Tribes of Warm Springs : Annual Report For Fiscal Year, October 2007 – September 2008.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gerstenberger, Ryan

    2009-07-27

    This progress report describes work performed by the Confederated Tribes of Warm Springs (CTWSRO) portion of the Hood River Production Program Monitoring and Evaluation Project (HRPP) during the 2008 fiscal year. A total of 64,736 hatchery winter steelhead, 12,108 hatchery summer steelhead, and 68,426 hatchery spring Chinook salmon smolts were acclimated and released in the Hood River basin during the spring. The HRPP exceeded program goals for a release of and 50,000 winter steelhead but fell short of the steelhead release goals of 30,000 summer steelhead and 75,000 spring Chinook in 2008. Passive Integrated Transponders (PIT) tags were implanted inmore » 6,652 hatchery winter steelhead, and 1,196 hatchery summer steelhead, to compare migratory attributes and survival rates of hatchery fish released into the Hood River. Water temperatures were recorded at six locations within the Hood River subbasin to monitor for compliance with Oregon Department of Environmental Quality water quality standards. A preseason spring Chinook salmon adult run forecast was generated, which predicted an abundant return adequate to meet escapement goal and brood stock needs. As a result the tribal and sport fisheries were opened. A tribal creel was conducted from May 22 to July 18 during which an estimated 172 spring Chinook were harvested. One hundred sixteen Spring Chinook salmon redds were observed and 72 carcasses were inspected on 19.4 miles of spawning grounds throughout the Hood River Basin during 2008. Annual salvage operations were completed in two irrigation canals resulting in the liberation of 1,641 fish back to the Hood River.« less

  3. Control of Cr6+ emissions from gas metal arc welding using a silica precursor as a shielding gas additive.

    PubMed

    Topham, Nathan; Wang, Jun; Kalivoda, Mark; Huang, Joyce; Yu, Kuei-Min; Hsu, Yu-Mei; Wu, Chang-Yu; Oh, Sewon; Cho, Kuk; Paulson, Kathleen

    2012-03-01

    Hexavalent chromium (Cr(6+)) emitted from welding poses serious health risks to workers exposed to welding fumes. In this study, tetramethylsilane (TMS) was added to shielding gas to control hazardous air pollutants produced during stainless steel welding. The silica precursor acted as an oxidation inhibitor when it decomposed in the high-temperature welding arc, limiting Cr(6+) formation. Additionally, a film of amorphous SiO(2) was deposited on fume particles to insulate them from oxidation. Experiments were conducted following the American Welding Society (AWS) method for fume generation and sampling in an AWS fume hood. The results showed that total shielding gas flow rate impacted the effectiveness of the TMS process. Increasing shielding gas flow rate led to increased reductions in Cr(6+) concentration when TMS was used. When 4.2% of a 30-lpm shielding gas flow was used as TMS carrier gas, Cr(6+) concentration in gas metal arc welding (GMAW) fumes was reduced to below the 2006 Occupational Safety and Health Administration standard (5 μg m(-3)) and the efficiency was >90%. The process also increased fume particle size from a mode size of 20 nm under baseline conditions to 180-300 nm when TMS was added in all shielding gas flow rates tested. SiO(2) particles formed in the process scavenged nanosized fume particles through intercoagulation. Transmission electron microscopy imagery provided visual evidence of an amorphous film of SiO(2) on some fume particles along with the presence of amorphous SiO(2) agglomerates. These results demonstrate the ability of vapor phase silica precursors to increase welding fume particle size and minimize chromium oxidation, thereby preventing the formation of hexavalent chromium.

  4. Influence of impact speed on head and brain injury outcome in vulnerable road user impacts to the car hood.

    PubMed

    Fredriksson, Rikard; Zhang, Liying; Boström, Ola; Yang, King

    2007-10-01

    EuroNCAP and regulations in Europe and Japan evaluate the pedestrian protection performance of cars. The test methods are similar and they all have requirements for the passive protection of the hood area at a pedestrian to car impact speed of 40 km/h. In Europe, a proposal for a second phase of the regulation mandates a brake-assist system along with passive requirements. The system assists the driver in optimizing the braking performance during panic braking, resulting in activation only when the driver brakes sufficiently. In a European study this was estimated to occur in about 50% of pedestrian accidents. A future system for brake assistance will likely include automatic braking, in response to a pre-crash sensor, to avoid or mitigate injuries of vulnerable road users. An important question is whether these systems will provide sufficient protection, or if a parallel, passive pedestrian protection system will be necessary. This study investigated the influence of impact speed on head and brain injury risk, in impacts to the carhood. One car model was chosen and a rigid adjustable plate was mounted under the hood. Free-flying headform impacts were carried out at 20 and 30 km/h head impact velocities at different under-hood distances, 20 to 100 mm; and were compared to earlier tests at 40 km/h. The EEVC WG17 adult pedestrian headform was used for non-rotating tests and a Hybrid III adult 50th percentile head was used for rotational tests where linear and rotational acceleration was measured. Data from the rotational tests was used as input to a validated finite element model of the human head, the Wayne State University Head Injury Model (WSUHIM). The model was utilized to assess brain injury risk and potential injury mechanism in a pedestrian-hood impact. Although this study showed that it was not necessarily true that a lower HIC value reduced the risk for brain injury, it appeared, for the tested car model, under-hood distances of 60 mm in 20 km/h and 80 mm

  5. Lung fibrosis in Sprague-Dawley rats, induced by exposure to manual metal arc-stainless steel welding fumes.

    PubMed

    Yu, I J; Song, K S; Chang, H K; Han, J H; Kim, K J; Chung, Y H; Maeng, S H; Park, S H; Han, K T; Chung, K H; Chung, H K

    2001-09-01

    To investigate the disease process of pneumoconiosis induced by welding-fume exposure, a lung fibrosis model was established by building a stainless steel arc welding fume generation system and exposing male Sprague-Dawley rats for 90 days. The rats were exposed to welding fumes with concentrations of 57-67 mg/m3 (low dose) and 105-118 mg/m3 (high dose) total suspended particulates for 2 h per day in an inhalation chamber for 90 days. The concentrations of the main metals, Fe, Mn, Cr, and Ni, were measured in the welding fumes, plus the gaseous compounds, including nitrous gases and ozone, were monitored. During the exposure period, the animals were sacrificed after the initial 2-h exposure and after 15, 30, 60, and 90 days. Histopathological examinations were conducted on the animals' upper respiratory tract, including the nasal pathway and conducting airway, plus the gas exchange region, including the alveolar ducts, alveolar sacs, and alveoli. When compared to the control group, the lung weights did not increase significantly in the low-dose group, yet in the high-dose group there was a significant increase from day 15 to day 90. The histopathological examination combined with fibrosis-specific staining (Masson's trichrome) indicated that the lungs in the low-dose group did not exhibit any progressive fibrotic changes. Whereas, the lungs in the high-dose group exhibited early delicate fibrosis from day 15, which progressed into the perivascular and peribronchiolar regions by day 30. Interstitial fibrosis appeared at day 60 and became prominent by day 90, along with the additional appearance of pleural fibrosis. Accordingly, it would appear that a significant dose of welding-fume exposure was required to induce lung fibrosis.

  6. Recovery from manual metal arc-stainless steel welding-fume exposure induced lung fibrosis in Sprague-Dawley rats.

    PubMed

    Yu, Il Je; Song, Kyung Seuk; Chang, Hee Kyung; Han, Jeong Hee; Chung, Yong Hyun; Han, Kuy Tae; Chung, Kyu Hyuck; Chung, Ho Keun

    2003-08-28

    Welders with radiographic pneumoconiosis abnormalities have exhibited a gradual clearing of the X-ray identified effects following removal from exposure. In some cases, the pulmonary fibrosis associated with welding fumes appears in a more severe form in welders. Accordingly, to investigate the disease and recovery process of pneumoconiosis induced by welding-fume exposure, rats were exposed to welding fumes with concentrations of 63.6+/-4.1 mg/m(3) (low dose) and 107.1+/-6.3 mg/m(3) (high dose) of total suspended particulate for 2 h per day in an inhalation chamber for a total of 2 h or 15, 30, 60 or 90 days. Thereafter, the rats were no longer exposed and allowed to recover from the welding fume-induced lung fibrosis for 90 days. When compared to the unexposed control group, the lung weights significantly increased in both the low- and high-dose rats from day 15 to 90. A histopathological examination combined with fibrosis-specific staining revealed that the lungs from the low-dose rats did not exhibit any significant progressive fibrotic changes. Whereas, the lungs from the high-dose rats exhibited early delicate fibrosis from day 15, which progressed into the perivascular and peribronchiolar regions by day 30. Interstitial fibrosis appeared at day 60 and became prominent by day 90, along with the additional appearance of pleural fibrosis. Recovery, evaluated based on the body and lung weights and a histopathological examination, was observed in both the high and low-dose rats that were exposed up to 30 days. The rats exposed for 60-90 days at the low dose also recovered from the fibrosis, yet the rats exposed for 60-90 days at the high dose did not fully recover. Consequently, recovery from pneumoconiosis induced by welding-fume exposure was observed when the degree of exposure was short-term and moderate.

  7. Fabrication and Optimization of Carbon Nanomaterial-Based Lithium-Ion Battery Anodes

    DTIC Science & Technology

    2012-03-01

    preparation setup under the fume hood with NMP solvent, glass pipette with dispenser, and the ball milled powder mixture containing LiFePO4 , acetylene...minutes. ............................................................................. 18 Figure 12. (a) LiFePO4 slurry applied on foil current collector...and (b) LiFePO4 slurry casted with applicator and (c) LiFePO4 casted (From [15])....... 18 Figure 13. MTI disc cutter used to cut individual

  8. Grazing-Angle Fourier Transform Infrared Spectroscopy for Surface Cleanliness Verification

    DTIC Science & Technology

    2003-03-01

    coating. 34 North Island personnel were also interested in using the portable FTIR instrument to detect a trivalent chromium conversion coating on... trivalent chromium coating on aluminum panels. 35 Following the successful field-test at NADEP North Island in December 2000, a second demonstration of...contaminated, the panels were allowed to dry under a fume hood to evaporate the solvent. They were then placed in a desiccator for final drying. This

  9. Changes in blood manganese concentration and MRI t1 relaxation time during 180 days of stainless steel welding-fume exposure in cynomolgus monkeys.

    PubMed

    Sung, Jae Hyuck; Kim, Choong Yong; Yang, Seoung Oh; Khang, Hyun Soo; Cheong, Hae Kwan; Lee, Jong Seong; Song, Chang-Woo; Park, Jung Duck; Han, Jeong Hee; Chung, Yong Hyun; Choi, Byung Sun; Kwon, Il Hoon; Cho, Myung Haeng; Yu, Il Je

    2007-01-01

    Welders are at risk of being exposed to high concentrations of welding fumes and developing pneumoconiosis or other welding-fume exposure-related diseases. Among such diseases, manganism resulting from welding-fume exposure remains a controversial issue, as although the movement of manganese into specific brain regions has been established, the similar movement of manganese presented with other metals, such as welding fumes, has not been clearly demonstrated as being similar to that of manganese alone. Meanwhile, the competition between Mn and iron for iron transporters, such as transferrin and DMT-1, to the brain has also been implicated in the welding-fume exposure. Thus, the increased signal intensities in the basal ganglia, including the globus pallidus and subcortical frontal white matter, based on T1-weighted magnetic resonances in welders, require further examination as regards the correspondence with an increased manganese concentration. Accordingly, to investigate the movement of manganese after welding-fume exposure, 6 cynomolgus monkeys were acclimated for 1 mo and assigned to 3 dose groups: unexposed, low dose of (total suspended particulate [TSP] 31 mg/m3, 0.9 mg/m3 of Mn), and high dose of total suspended particulate (62 mg/m3 TSP, 1.95 mg/m3 of Mn). The primates were exposed to manual metal-arc stainless steel (MMA-SS) welding fumes for 2 h/day in an inhalation chamber system equipped with an automatic fume generator for 6 mo. Magnetic resonance imaging (MRI) studies of the basal ganglia were conducted before the initiation of exposure and thereafter every month. During the exposure, the blood chemistry was monitored every 2 wk and the concentrations of metal components in the blood were measured every 2 wk and compared with ambient manganese concentrations. The manganese concentrations in the blood did not show any significant increase until after 2 mo of exposure, and then reached a plateau after 90 days of exposure, showing that an exposure period

  10. Beyond 2001: a silvicultural odyssey to sustaining terrestrial and aquatic ecosystems? Proceedings of the 2001 national silviculture workshop, May 6-10, Hood River, Oregon.

    Treesearch

    Sharon Parker; Susan Stevens Hummel

    2002-01-01

    The 2001 National Silviculture Workshop was held in Hood River, Oregon, and hosted by the Mt. Hood National Forest, the Gifford Pinchot National Forest, and the Pacific Northwest Research Station. The Washington Office Vegetation Management and Protection Research and Forest and Grassland staffs are ongoing sponsors of the biennial workshop, which began in 1973 in...

  11. Evaluation of the Pulmonary Toxicity of a Fume Generated from a Nickel-, Copper-Based Electrode to be Used as a Substitute in Stainless Steel Welding.

    PubMed

    Antonini, James M; Badding, Melissa A; Meighan, Terence G; Keane, Michael; Leonard, Stephen S; Roberts, Jenny R

    2014-01-01

    Epidemiology has indicated a possible increase in lung cancer among stainless steel welders. Chromium (Cr) is a primary component of stainless steel welding fume. There is an initiative to develop alternative welding consumables [nickel (Ni)- and copper (Cu)-based alloys] that do not contain Cr. No study has been performed to evaluate the toxicity of fumes generated from Ni- and Cu-based consumables. Dose-response and time-course effects on lung toxicity of a Ni- and Cu-based welding fume (Ni-Cu WF) were examined using an in vivo and in vitro bioassay, and compared with two other well-characterized welding fumes. Even though only trace amounts of Cr were present, a persistent increase in lung injury and inflammation was observed for the Ni-Cu WF compared to the other fumes. The difference in response appears to be due to a direct cytotoxic effect by the Ni-Cu WF sample on lung macrophages as opposed to an elevated production of reactive oxygen species (ROS).

  12. Evaluation of the Pulmonary Toxicity of a Fume Generated from a Nickel-, Copper-Based Electrode to be Used as a Substitute in Stainless Steel Welding

    PubMed Central

    Antonini, James M; Badding, Melissa A; Meighan, Terence G; Keane, Michael; Leonard, Stephen S; Roberts, Jenny R

    2014-01-01

    Epidemiology has indicated a possible increase in lung cancer among stainless steel welders. Chromium (Cr) is a primary component of stainless steel welding fume. There is an initiative to develop alternative welding consumables [nickel (Ni)- and copper (Cu)-based alloys] that do not contain Cr. No study has been performed to evaluate the toxicity of fumes generated from Ni- and Cu-based consumables. Dose–response and time-course effects on lung toxicity of a Ni- and Cu-based welding fume (Ni–Cu WF) were examined using an in vivo and in vitro bioassay, and compared with two other well-characterized welding fumes. Even though only trace amounts of Cr were present, a persistent increase in lung injury and inflammation was observed for the Ni–Cu WF compared to the other fumes. The difference in response appears to be due to a direct cytotoxic effect by the Ni–Cu WF sample on lung macrophages as opposed to an elevated production of reactive oxygen species (ROS). PMID:25392698

  13. Refreshing the Aged Latent Fingerprints with Ionizing Radiation Prior to the Cyanoacrylate Fuming Procedure: A Preliminary Study.

    PubMed

    Ristova, Mimoza M; Radiceska, Pavlina; Bozinov, Igorco; Barandovski, Lambe

    2016-05-01

    One of the crucial factors determining the cyanoacrylate deposit quality over latent fingerprints appeared to be the extent of the humidity. This work focuses on the enhancement/refreshment of age-degraded latent fingerprints by irradiating the samples with UV, X-ray, or thermal neutrons prior to the cyanoacrylate (CA) fuming. Age degradation of latent fingerprints deposited on glass surfaces was examined through the decrease in the number of characteristic minutiae counts over time. A term "critical day" was introduced for the time at which the average number of identifiable minutiae definitions drops to one-half. Fingerprints older than their "critical day" were exposed to either UV, X-ray, or thermal neutrons. Identical reference samples were kept unexposed. All samples, both reference and irradiated, were developed during a single CA fuming procedure. Comparative latent fingerprint analysis showed that exposure to ionizing radiation enhances the CA fuming, yielding a 20-30% increase in average minutiae count. © 2015 American Academy of Forensic Sciences.

  14. Physicomechanical enhancement on Portland composite concrete using silica fume as replacement material

    NASA Astrophysics Data System (ADS)

    Husin, Wan Norsariza Wan; Johari, Izwan

    2017-09-01

    The addition of supplementary cementitious materials may change the physical and mechanical properties of concrete. Mineral additions which are also known as mineral admixtures have been used with cement for many years. However, this research did not use Ordinary Portland Cement (OPC) but using the Portland Cement Composite (PCC). The aim of this study is to determine the effect of partial substitution of PCC by silica fume (SF) on the physicomechanical properties especially the compressive strength of the hardened PCC-SF composite concrete. Silica fume was used to replace PCC at dosage levels of 5%, 10%, 15% and 20% by weight of cement in concrete. The results show that on 7 days the PCC concrete exhibited lower early age strength but PCC-SF concrete improved and gain strength up to grade 30 in 7 days. The utilisation of SF resulted in significant improvement of Portland composite concrete admixture.

  15. 42 CFR 84.1139 - Air velocity and noise levels; hoods and helmets; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Air velocity and noise levels; hoods and helmets; minimum requirements. 84.1139 Section 84.1139 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  16. 42 CFR 84.1139 - Air velocity and noise levels; hoods and helmets; minimum requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Air velocity and noise levels; hoods and helmets; minimum requirements. 84.1139 Section 84.1139 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  17. 42 CFR 84.1139 - Air velocity and noise levels; hoods and helmets; minimum requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Air velocity and noise levels; hoods and helmets; minimum requirements. 84.1139 Section 84.1139 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  18. 42 CFR 84.1139 - Air velocity and noise levels; hoods and helmets; minimum requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Air velocity and noise levels; hoods and helmets; minimum requirements. 84.1139 Section 84.1139 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  19. 42 CFR 84.1139 - Air velocity and noise levels; hoods and helmets; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Air velocity and noise levels; hoods and helmets; minimum requirements. 84.1139 Section 84.1139 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  20. EVALUATION OF FERTILIZATION FOLLOWING OVULATORY DELAY WITH THIRAM IN THE LONG-EVANS HOODED RAT

    EPA Science Inventory

    Evaluation of fertilization following ovulatory delay with thiram in the Long-Evans Hooded Rat

    1TE Stoker, 1* S Jeffay, and 1 SD Perreault.

    1Gamete and Early Embryogenesis Biology Branch and 2 Endocrinology Branch, Reproductive Toxicology Division, NHEERL, US EPA, R...

  1. The gut microbiome of hooded cranes (Grus monacha) wintering at Shengjin Lake, China.

    PubMed

    Zhao, Guanghong; Zhou, Lizhi; Dong, Yuanqiu; Cheng, Yuanyuan; Song, Yunwei

    2017-06-01

    Gut microbes of animals play critical roles in processes such as digestion and immunity. Therefore, identifying gut microbes will shed light on understanding the annual life of animal species, particularly those that are threatened or endangered. In the present study, we conducted nucleotide sequence analyses of the 16S rRNA genes of gut microbiome of the hooded cranes (Grus monacha) wintering at Shengjin Lake, China, by Illumina high-throughput sequencing technology. We acquired 503,398 high-quality sequences and 785 operational taxonomic units (OTUs) from 15 fecal samples from different cranes, representing 22 phyla that were dominated by Firmicutes, Proteobacteria, and Actinobacteria. A total of 305 genera were identified that were dominated by Clostridium, Lysinibacillus, and Enterobacter. The core gut microbiome comprised 26 genera, including many probiotic species such as Clostridium, Bacillus, Cellulosilyticum, and Cellulomonas that could catabolize cellulose. The findings reported here contribute to our knowledge of the microbiology of hooded cranes and will likely advance efforts to protect waterbirds that inhabit Shengjin Lake Reserve during winter. © 2017 The Authors. MicrobiologyOpen published by John Wiley & Sons Ltd.

  2. Reduction of Acute Inflammatory Effects of Fumed Silica Nanoparticles in the Lung by Adjusting Silanol Display through Calcination and Metal Doping

    PubMed Central

    Sun, Bingbing; Pokhrel, Suman; Dunphy, Darren R.; Zhang, Haiyuan; Ji, Zhaoxia; Wang, Xiang; Wang, Meiying; Liao, Yu-Pei; Chang, Chong Hyun; Dong, Juyao; Li, Ruibin; Mädler, Lutz; Brinker, C. Jeffrey; Nel, André E.; Xia, Tian

    2015-01-01

    The production of pyrogenic (fumed) silica is increasing worldwide at a 7% annual growth rate, including expanded use in food, pharmaceuticals and other industrial products. Synthetic amorphous silica, including fumed silica, has been generally recognized as safe (GRAS) for use in food products by the Food and Drug Administration (FDA). However, emerging evidence from experimental studies now suggests that fumed silica could be hazardous due to its siloxane ring structure, high silanol density, and “string-of-pearl-like” aggregate structure, which could combine to cause membrane disruption, generation of reactive oxygen species, pro-inflammatory effects, and liver fibrosis. Based on this structure-activity analysis (SAA), we investigated whether calcination and rehydration of fumed silica changes its hazard potential in the lung due to an effect on silanol density display. This analysis demonstrated that the accompanying change in surface reactivity could indeed impact cytokine production in macrophages and acute inflammation in the lung, in a manner that is dependent on siloxane ring reconstruction. Confirmation of this SAA in vivo, prompted us to consider safer design of fumed silica properties by titanium (Ti) and aluminum (Al) doping (0–7%), using flame spray pyrolysis (FSP). Detailed characterization revealed that increased Ti and Al doping could reduce surface silanol density and expression of three-membered siloxane rings, leading to dose-dependent reduction in hydroxyl radical generation, membrane perturbation, potassium efflux, NLRP3 inflammasome activation and cytotoxicity in THP-1 cells. The reduction of NLRP3 inflammasome activation was also confirmed in bone marrow-derived macrophages (BMDMs). Ti- and to a lesser extent Al-doping, also ameliorated acute pulmonary inflammation, demonstrating the possibility of a safer design approach for fumed silica, should that be required for specific use circumstances. PMID:26200133

  3. A model for prediction of fume formation rate in gas metal arc welding (GMAW), globular and spray modes, DC electrode positive.

    PubMed

    Dennis, J H; Hewitt, P J; Redding, C A; Workman, A D

    2001-03-01

    Prediction of fume formation rate during metal arc welding and the composition of the fume are of interest to occupational hygienists concerned with risk assessment and to manufacturers of welding consumables. A model for GMAW (DC electrode positive) is described based on the welder determined process parameters (current, wire feed rate and wire composition), on the surface area of molten metal in the arc and on the partial vapour pressures of the component metals of the alloy wire. The model is applicable to globular and spray welding transfer modes but not to dip mode. Metal evaporation from a droplet is evaluated for short time increments and total evaporation obtained by summation over the life of the droplet. The contribution of fume derived from the weld pool and spatter (particles of metal ejected from the arc) is discussed, as are limitations of the model. Calculated droplet temperatures are similar to values determined by other workers. A degree of relationship between predicted and measured fume formation rates is demonstrated but the model does not at this stage provide a reliable predictive tool.

  4. 42 CFR 84.1140 - Dust, fume, and mist respirators; performance requirements; general.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Dust, fume, and mist respirators; performance requirements; general. 84.1140 Section 84.1140 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY...

  5. 42 CFR 84.1140 - Dust, fume, and mist respirators; performance requirements; general.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Dust, fume, and mist respirators; performance requirements; general. 84.1140 Section 84.1140 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY...

  6. 42 CFR 84.1140 - Dust, fume, and mist respirators; performance requirements; general.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Dust, fume, and mist respirators; performance requirements; general. 84.1140 Section 84.1140 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY...

  7. 42 CFR 84.1140 - Dust, fume, and mist respirators; performance requirements; general.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Dust, fume, and mist respirators; performance requirements; general. 84.1140 Section 84.1140 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY...

  8. 42 CFR 84.1140 - Dust, fume, and mist respirators; performance requirements; general.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Dust, fume, and mist respirators; performance requirements; general. 84.1140 Section 84.1140 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY...

  9. Computational Fluid Dynamic Modeling of Zinc Slag Fuming Process in Top-Submerged Lance Smelting Furnace

    NASA Astrophysics Data System (ADS)

    Huda, Nazmul; Naser, Jamal; Brooks, Geoffrey; Reuter, Markus A.; Matusewicz, Robert W.

    2012-02-01

    Slag fuming is a reductive treatment process for molten zinciferous slags for extracting zinc in the form of metal vapor by injecting or adding a reductant source such as pulverized coal or lump coal and natural gas. A computational fluid dynamic (CFD) model was developed to study the zinc slag fuming process from imperial smelting furnace (ISF) slag in a top-submerged lance furnace and to investigate the details of fluid flow, reaction kinetics, and heat transfer in the furnace. The model integrates combustion phenomena and chemical reactions with the heat, mass, and momentum interfacial interaction between the phases present in the system. A commercial CFD package AVL Fire 2009.2 (AVL, Graz, Austria) coupled with a number of user-defined subroutines in FORTRAN programming language were used to develop the model. The model is based on three-dimensional (3-D) Eulerian multiphase flow approach, and it predicts the velocity and temperature field of the molten slag bath, generated turbulence, and vortex and plume shape at the lance tip. The model also predicts the mass fractions of slag and gaseous components inside the furnace. The model predicted that the percent of ZnO in the slag bath decreases linearly with time and is consistent broadly with the experimental data. The zinc fuming rate from the slag bath predicted by the model was validated through macrostep validation process against the experimental study of Waladan et al. The model results predicted that the rate of ZnO reduction is controlled by the mass transfer of ZnO from the bulk slag to slag-gas interface and rate of gas-carbon reaction for the specified simulation time studied. Although the model is based on zinc slag fuming, the basic approach could be expanded or applied for the CFD analysis of analogous systems.

  10. Fuels planning: science synthesis and integration; environmental consequences fact sheet 12: Water Erosion Prediction Project (WEPP) Fuel Management (FuMe) tool

    Treesearch

    William Elliot; David Hall

    2005-01-01

    The Water Erosion Prediction Project (WEPP) Fuel Management (FuMe) tool was developed to estimate sediment generated by fuel management activities. WEPP FuMe estimates sediment generated for 12 fuel-related conditions from a single input. This fact sheet identifies the intended users and uses, required inputs, what the model does, and tells the user how to obtain the...

  11. Double shroud delivery of silica precursor for reducing hexavalent chromium in welding fume.

    PubMed

    Wang, Jun; Kalivoda, Mark; Guan, Jianying; Theodore, Alexandros; Sharby, Jessica; Wu, Chang-Yu; Paulson, Kathleen; Es-Said, Omar

    2012-01-01

    The welding process yields a high concentration of nanoparticles loaded with hexavalent chromium (Cr(6+)), a known human carcinogen. Previous studies have demonstrated that using tetramethylsilane (TMS) as a shielding gas additive can significantly reduce the Cr(6+) concentration in welding fume particles. In this study, a novel insulated double shroud torch (IDST) was developed to further improve the reduction of airborne Cr(6+) concentration by separating the flows of the primary shielding gas and the TMS carrier gas. Welding fumes were collected from a welding chamber in the laboratory and from a fixed location near the welding arc in a welding facility. The Cr(6+) content was analyzed with ion chromatography and X-ray photoelectron spectroscopy (XPS). Results from the chamber sampling demonstrated that the addition of 3.2 ≈ 5.1% of TMS carrier gas to the primary shielding gas resulted in more than a 90% reduction of airborne Cr(6+) under all shielding gas flow rates. The XPS result confirmed complete elimination of Cr(6+) inside the amorphous silica shell. Adding 100 ≈ 1000 ppm of nitric oxide or carbon monoxide to the shielding gas could also reduce Cr(6+) concentrations up to 57% and 35%, respectively; however, these reducing agents created potential hazards from the release of unreacted agents. Results of the field test showed that the addition of 1.6% of TMS carrier gas to the primary shielding gas reduced Cr(6+) concentration to the limitation of detection (1.1 μg/m(3)). In a worst-case scenario, if TMS vapor leaked into the environment without decomposition and ventilation, the estimated TMS concentration in the condition of field sampling would be a maximum 5.7 ppm, still well below its flammability limit (1%). Based on a previously developed cost model, the use of TMS increases the general cost by 3.8%. No visual deterioration of weld quality caused by TMS was found, although further mechanical testing is necessary.

  12. Ignition Delays of Alkyl Thiophosphites with White and Red Fuming Nitric Acids Within Temperature Range 80 to -105 F

    NASA Technical Reports Server (NTRS)

    Miller, Riley O; Ladanyi, Dezso J

    1953-01-01

    Ignition delays of alkyl thiophosphites were obtained in a modified open-cup apparatus and a small-scale rocket engine apparatus. At -40 F, mixed alkyl thiophosphites gave short delays with white fuming nitric acid containing 2 percent water and red fuming nitric acids of widely varying compositions. At -40 F and higher, triethyl trithiophosphite blended with as much as 40 percent n-heptane gave satisfactory self-igniting properties at temperatures as low as -76 F.

  13. Development of Welding Fumes Health Index (WFHI) for Welding Workplace's Safety and Health Assessment.

    PubMed

    Hariri, Azian; Paiman, Nuur Azreen; Leman, Abdul Mutalib; Md Yusof, Mohammad Zainal

    2014-08-01

    This study aimed to develop an index that can rank welding workplace that associate well with possible health risk of welders. Welding Fumes Health Index (WFHI) were developed based on data from case studies conducted in Plant 1 and Plant 2. Personal sampling of welding fumes to assess the concentration of metal constituents along with series of lung function tests was conducted. Fifteen metal constituents were investigated in each case study. Index values were derived from aggregation analysis of metal constituent concentration while significant lung functions were recognized through statistical analysis in each plant. The results showed none of the metal constituent concentration was exceeding the permissible exposure limit (PEL) for all plants. However, statistical analysis showed significant mean differences of lung functions between welders and non-welders. The index was then applied to one of the welding industry (Plant 3) for verification purpose. The developed index showed its promising ability to rank welding workplace, according to the multiple constituent concentrations of welding fumes that associates well with lung functions of the investigated welders. There was possibility that some of the metal constituents were below the detection limit leading to '0' value of sub index, thus the multiplicative form of aggregation model was not suitable for analysis. On the other hand, maximum or minimum operator forms suffer from compensation issues and were not considered in this study.

  14. Triglycerides, total cholesterol, high density lipoprotein cholesterol and low density lipoprotein cholesterol in rats exposed to premium motor spirit fumes.

    PubMed

    Aberare, Ogbevire L; Okuonghae, Patrick; Mukoro, Nathaniel; Dirisu, John O; Osazuwa, Favour; Odigie, Elvis; Omoregie, Richard

    2011-06-01

    Deliberate and regular exposure to premium motor spirit fumes is common and could be a risk factor for liver disease in those who are occupationally exposed. A possible association between premium motor spirit fumes and plasma levels of triglyceride, total cholesterol, high density lipoprotein cholesterol and low density lipoprotein cholesterol using a rodent model could provide new insights in the pathology of diseases where cellular dysfunction is an established risk factor. The aim of this study was to evaluate the possible effect of premium motor spirit fumes on lipids and lipoproteins in workers occupationally exposed to premium motor spirit fumes using rodent model. Twenty-five Wister albino rats (of both sexes) were used for this study between the 4(th) of August and 7(th) of September, 2010. The rats were divided into five groups of five rats each. Group 1 rats were not exposed to premium motor spirit fumes (control group), group 2 rats were exposed for 1 hour daily, group 3 for 3 hours daily, group 4 for 5 hours daily and group 5 for 7 hours daily. The experiment lasted for a period of 4 weeks. Blood samples obtained from all the groups after 4 weeks of exposure were used for the estimation of plasma levels of triglyceride, total cholesterol, high density lipoprotein- cholesterol and low density lipoprotein- cholesterol. Results showed significant increase in means of plasma total cholesterol and low density lipoprotein levels (P<0.05). The mean triglyceride and total body weight were significantly lower (P<0.05) in the exposed group when compared with the unexposed. The plasma level of high density lipoprotein, the ratio of low density lipoprotein to high density lipoprotein and the ratio of total cholesterol to high density lipoprotein did not differ significantly in exposed subjects when compared with the control group. These results showed that frequent exposure to petrol fumes may be highly deleterious to the liver cells.

  15. A field investigation of concrete overlays containing latex, silica fume, or Pyrament cement.

    DOT National Transportation Integrated Search

    1996-01-01

    This study evaluated latex-modified concretes (LMC) and concretes containing silica fume (SFC) or Pyrament-blended cement (PBCC) in bridge deck overlays in the field. The condition of the overlays was monitored for 4 years. LMC and SFC were placed in...

  16. Stainless steel manual metal arc welding fumes in rats.

    PubMed Central

    Kalliomäki, P L; Lakomaa, E; Kalliomäki, K; Kiilunen, M; Kivelä, R; Vaaranen, V

    1983-01-01

    Forty two male Wistar rats were exposed to manual metal arc (MMA) stainless steel (SS) welding fumes generated by an automatic welding device for "nose-only" exposure. The exposure simulated an actual MMA/SS welding environment as closely as possible. For the retention study, the duration of exposure was one hour per workday for one, two, three, of four weeks and for the clearance study four weeks. The retention and clearance of the chromium, nickel, and iron found in MMA/SS welding fumes in the rats' lungs were studied as was the distribution of the metals to other organs. Instrumental neutron activation analysis (INAA) was used for the multi-element chemical activation analyses. The concentrations of chromium and nickel in the blood and the urine were determined by atomic absorption method (AAS). The retention of exogenous iron was determined by a magnetic measuring method. The results indicated that the lungs were the target organs of soluble hexavalent chromates. The half times of lung clearance for Cr, Ni, and Fe were 40 +/- 4 d, 20 +/- d, and 50 +/- 10 d. When the lung clearance curves are compared, the half times of Cr and Fe lung clearance are similar but nickel disappears faster. The distribution and clearance patterns of chromium to other organs differ from those obtained after single intravenous or intratracheal injections of alkaline chromates. PMID:6830723

  17. MOUNT HOOD WILDERNESS AND ADJACENT AREAS, OREGON.

    USGS Publications Warehouse

    Keith, T.E.C.; Causey, J.D.

    1984-01-01

    A mineral survey of the Mount Hood Wilderness, Oregon, was conducted. Geochemical data indicate two areas of substantiated mineral-resource potential containing weak epithermal mineralization: an area of the north side of Zigzag Mountain where vein-type lead-zinc-silver deposits occur and an area of the south side of Zigzag Mountain, where the upper part of a quartz diorite pluton has propylitic alteration associated with mineralization of copper, gold, silver, lead, and zinc in discontinuous veins. Geothermal-resource potential for low- to intermediate-temperature (less than 248 degree F) hot-water systems in the wilderness is probable in these areas. Part of the wilderness is classified as a Known Geothermal Resource Area (KGRA), which is considered to have probable geothermal-resource potential, and two parts of the wilderness have been included in geothermal lease areas.

  18. Occupational hypersensitivity pneumonitis in a smelter exposed to zinc fumes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ameille, J.; Brechot, J.M.; Brochard, P.

    1992-03-01

    A smelter exposed to zinc fumes reported severe recurrent episodes of cough, dyspnea and fever. Bronchoalveolar lavage showed a marked increase in lymphocytes count with predominance of CD8 T-lymphocytes. Presence of zinc in alveolar macrophages was assessed by analytic transmission electron microscopy. This is the first case of recurrent bronchoalveolitis related to zinc exposure in which the clinical picture and BAL results indicate a probable hypersensitivity pneumonitis.

  19. Contraction-free, fume-fixed longitudinal sections of fresh frozen muscle

    NASA Technical Reports Server (NTRS)

    Riley, Danny A.; Slocum, Glenn R.

    1988-01-01

    Contraction damage occurring when longitudinal frozen sections of fresh unfixed muscles are thawed on microscope slides has limited histological examination of this tissue mainly to cross sections. Longitudinally oriented sections are advantageous for investigating properties that vary along the length of the muscle fibers. A fume fixation technique has been developed for preventing contraction of thick longitudinal frozen sections. The technique is compatible with histochemical staining of enzymes.

  20. Risk of ischemic heart disease following occupational exposure to welding fumes: a systematic review with meta-analysis.

    PubMed

    Mocevic, Emina; Kristiansen, Pernille; Bonde, Jens Peter

    2015-04-01

    Air pollution has been linked to an increased risk of ischemic heart disease (IHD), but less is known about occupational exposure to welding fumes and the risk of IHD. The objective of this paper was to review the epidemiological evidence on causal links between welding fume exposure and risk of IHD and to investigate whether the risk of IHD depends on specific welding characteristics. A systematic search in Medline 1979-2013 and EMBASE 1974-2013 identified 18 epidemiological studies with at least one risk estimate of IHD morbidity or mortality among workers exposed to welding fumes. Following an assessment of completeness of reporting, confounding, and bias, each risk estimate was characterized as more or less reliable. Pooled risk estimates were computed across studies by random effect meta-analyses. The weighted relative risk (RR) for IHD following exposure to welding fumes was 1.09 [95 % confidence interval (CI) 1.00, 1.19]. We calculated a RR of 1.39 (95 % CI 0.96, 2.02) among studies using an internal reference group and 1.08 (95 % CI 0.99, 1.18) for studies using an external reference group. An increased risk was observed for acute myocardial infarction RR = 1.69 (95 % CI 1.18, 2.42) and other IHDs RR = 1.06 (95 % CI 0.98, 1.14). There was too limited evidence to evaluate the risk of IHD related to specific welding characteristics. Several studies indicate that welding is associated with a moderately increased risk of IHD; however, bias and confounding cannot be ruled out with reasonable confidence.

  1. West shore hood canal outfall windshield survey SR 101 MP 293.5 tO 341.0

    DOT National Transportation Integrated Search

    1996-08-01

    Western Washington's population increased dramatically during the last 40 years. The west shore of Hood Canal is now largely settled with the homes of retirees and seasonal residents. Many of these beachfront houses are connected to septic systems th...

  2. An investigation of fibrogenic and other toxic effects of arc-welding fume particles deposited in the rat lung.

    PubMed

    Hicks, R; Al-Shamma, K J; Lam, H F; Hewitt, P J

    1983-12-01

    Lung burdens of deposited particles from fumes generated by arc-welding were established in rats by single inhalation exposures, repeated intermittent exposure or by intratracheal injection. Fumes from manual metal arc-welding using flux-coated mild-steel rods (MMA-MS) were compared with those from metal inert-gas welding with stainless steel wire (MIG-SS). After initial rapid clearance of deposited material from the lungs, persistent residual deposits remained. Such residues resulting from single inhalation were small and confined mainly to peribronchial accumulations in macrophage clusters. Deposits remaining after repeated inhalation were larger and more widespread. Intratracheal administration (50 mg) established massive residual deposits, giving nodular accumulations in peribronchial, subpleural and perivascular sites, with substantial alveolar parenchymal involvement. Deposits from both types of fumes contained predominantly iron. Particles from stainless steel also contained chromium, but concentrations of this element were low in deposits from MMA-MS fumes. MMA-MS deposits contained silica, probably amorphous. Long-term studies (up to 450 days) attempted to detect evidence of fibrosis resulting from particle burdens. Low-grade collagen fibre layers developed at margins of MMA-MS nodules. Diffuse reticulin fibre networks occurred within MIG-SS aggregates. Tissue hydroxyproline levels were increased (doubled) in lungs with intratracheal burdens of MMA-MS particles, but no significant increases resulted from MIG-SS. The major lesions were nodular aggregates of particle-laden macrophages with giant-cell formation, and alveolar epithelial thickening with atelectasis.

  3. U.S. Transportation Secretary Ray LaHood announces federal ban on texting for commercial truck drivers

    DOT National Transportation Integrated Search

    2010-01-26

    U.S Transportation Secretary Ray LaHood today announced federal guidance to expressly prohibit texting by drivers of commercial vehicles such as large trucks and buses. The prohibition is effective immediately and is the latest in a series of actions...

  4. Lifetime Occupational Exposure to Dusts, Gases and Fumes Is Associated with Bronchitis Symptoms and Higher Diffusion Capacity in COPD Patients

    PubMed Central

    Rodríguez, Esther; Ferrer, Jaume; Zock, Jan-Paul; Serra, Ignasi; Antó, Josep M.; de Batlle, Jordi; Kromhout, Hans; Vermeulen, Roel; Donaire-González, David; Benet, Marta; Balcells, Eva; Monsó, Eduard; Gayete, Angel; Garcia-Aymerich, Judith

    2014-01-01

    Background Occupational exposure to dusts, gases and fumes has been associated with reduced FEV1 and sputum production in COPD patients. The effect of occupational exposure on other characteristics of COPD, especially those reflecting emphysema, has not been studied in these patients. Methods We studied 338 patients hospitalized for a first exacerbation of COPD in 9 Spanish hospitals, obtaining full occupational history in a face-to-face interview; job codes were linked to a job exposure matrix for semi-quantitative estimation of exposure to mineral/biological dust, and gases/fumes for each job held. Patients underwent spirometry, diffusing capacity testing and analysis of gases in stable conditions. Quality of life, dyspnea and chronic bronchitis symptoms were determined with a questionnaire interview. A high- resolution CT scan was available in 133 patients. Results 94% of the patients included were men, with a mean age of 68(8.5) years and a mean FEV1% predicted 52 (16). High exposure to gases or fumes was associated with chronic bronchitis, and exposure to mineral dust and gases/fumes was associated with higher scores for symptom perception in the St. George’s questionnaire. No occupational agent was associated with a lower FEV1. High exposure to all occupational agents was associated with better lung diffusion capacity, in long-term quitters. In the subgroup with CT data, patients with emphysema had 18% lower DLCO compared to those without emphysema. Conclusions In our cohort of COPD patients, high exposure to gases or fumes was associated with chronic bronchitis, and high exposure to all occupational agents was consistently associated with better diffusion capacity in long-term quitters. PMID:24516659

  5. Genotoxic Evaluation of Mexican Welders Occupationally Exposed to Welding-Fumes Using the Micronucleus Test on Exfoliated Oral Mucosa Cells: A Cross-Sectional, Case-Control Study

    PubMed Central

    Jara-Ettinger, Ana Cecilia; López-Tavera, Juan Carlos; Zavala-Cerna, María Guadalupe; Torres-Bugarín, Olivia

    2015-01-01

    Background An estimated 800,000 people worldwide are occupationally exposed to welding-fumes. Previous studies show that the exposure to such fumes is associated with damage to genetic material and increased cancer risk. In this study, we evaluate the genotoxic effect of welding-fumes using the Micronucleus Test on oral mucosa cells of Mexican welders. Material and Methods We conducted a cross-sectional, matched case-control study of n = 66 (33 exposed welders, and 33 healthy controls). Buccal mucosa smears were collected and stained with acridine orange, observed under 100x optical amplification with a fluorescence lamp, and a single-blinded observer counted the number of micronuclei and other nuclear abnormalities per 2,000 observed cells. We compared the frequencies of micronuclei and other nuclear abnormalities, and fitted generalised linear models to investigate the interactions between nuclear abnormalities and the exposure to welding-fumes, while controlling for smoking and age. Results Binucleated cells and condensed-chromatin cells showed statistically significant differences between cases and controls. The frequency of micronuclei and the rest of nuclear abnormalities (lobed-nuclei, pyknosis, karyolysis, and karyorrhexis) did not differ significantly between the groups. After adjusting for smoking, the regression results showed that the occurrence of binucleated cells could be predicted by the exposure to welding-fumes plus the presence of tobacco consumption; for the condensed-chromatin cells, our model showed that the exposure to welding-fumes is the only reliable predictor. Conclusions Our findings suggest that Mexican welders who are occupationally exposed to welding-fumes have increased counts of binucleated and condensed-chromatin cells. Nevertheless, the frequencies of micronuclei and the rest of nuclear abnormalities did not differ between cases and controls. Further studies should shed more light on this subject. PMID:26244938

  6. Genotoxic Evaluation of Mexican Welders Occupationally Exposed to Welding-Fumes Using the Micronucleus Test on Exfoliated Oral Mucosa Cells: A Cross-Sectional, Case-Control Study.

    PubMed

    Jara-Ettinger, Ana Cecilia; López-Tavera, Juan Carlos; Zavala-Cerna, María Guadalupe; Torres-Bugarín, Olivia

    2015-01-01

    An estimated 800,000 people worldwide are occupationally exposed to welding-fumes. Previous studies show that the exposure to such fumes is associated with damage to genetic material and increased cancer risk. In this study, we evaluate the genotoxic effect of welding-fumes using the Micronucleus Test on oral mucosa cells of Mexican welders. We conducted a cross-sectional, matched case-control study of n = 66 (33 exposed welders, and 33 healthy controls). Buccal mucosa smears were collected and stained with acridine orange, observed under 100x optical amplification with a fluorescence lamp, and a single-blinded observer counted the number of micronuclei and other nuclear abnormalities per 2,000 observed cells. We compared the frequencies of micronuclei and other nuclear abnormalities, and fitted generalised linear models to investigate the interactions between nuclear abnormalities and the exposure to welding-fumes, while controlling for smoking and age. Binucleated cells and condensed-chromatin cells showed statistically significant differences between cases and controls. The frequency of micronuclei and the rest of nuclear abnormalities (lobed-nuclei, pyknosis, karyolysis, and karyorrhexis) did not differ significantly between the groups. After adjusting for smoking, the regression results showed that the occurrence of binucleated cells could be predicted by the exposure to welding-fumes plus the presence of tobacco consumption; for the condensed-chromatin cells, our model showed that the exposure to welding-fumes is the only reliable predictor. Our findings suggest that Mexican welders who are occupationally exposed to welding-fumes have increased counts of binucleated and condensed-chromatin cells. Nevertheless, the frequencies of micronuclei and the rest of nuclear abnormalities did not differ between cases and controls. Further studies should shed more light on this subject.

  7. Quantitative exposure matrix for asphalt fume, total particulate matter, and respirable crystalline silica among roofing and asphalt manufacturing workers.

    PubMed

    Fayerweather, William E; Trumbore, David C; Johnson, Kathleen A; Niebo, Ronald W; Maxim, L Daniel

    2011-09-01

    This paper summarizes available data on worker exposures to asphalt fume (soluble fraction), total particulate matter, and respirable crystalline silica (quartz) [hereinafter RCS] over a 30-year period in Owens Corning's asphalt production and roofing manufacturing plants. For the period 1977 through 2006, the air-monitoring database contains more than 1,400 personal samples for asphalt fume (soluble fraction), 2,400 personal samples for total particulate, and 1,300 personal samples for RCS. Unique process-job categories were identified for the asphalt production and roofing shingle manufacturing plants. Quantitative exposures were tabulated by agent, process-job, and calendar period to form an exposure matrix for use in subsequent epidemiologic studies of the respiratory health of these workers. Analysis of time trends in exposure data shows substantial and statistically significant exposure reductions for asphalt fume (soluble fraction), total particulate matter, and respirable crystalline silica at Owens Corning plants. Cumulative distribution plots for the most recent sampling period (2001-2006) show that 95% of the asphalt fume (soluble fraction) measurements were less than 0.25 mg/m3; 95% of the total particulate measurements were less than 2.2 mg/m3; and 95% of the RCS measurements were less than 0.05 mg/m3. Several recommendations are offered to improve the design of future monitoring efforts.

  8. Innovative ventilation system for animal anatomy laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lacey, D.R.; Smith, D.C.

    1997-04-01

    A unique ventilation system was designed and built to reduce formaldehyde fumes in the large animal anatomy lab at the Vet Medical Center at Cornell University. The laboratory includes four rooms totaling 5,500 ft{sup 2}. The main room has 2,300 ft{sup 2} and houses the laboratory where up to 60 students dissect as many as 12 horses at a time. Other rooms are a cold storage locker, an animal preparation room and a smaller lab for specialized instruction. The large animal anatomy laboratory has a history of air quality complaints despite a fairly high ventilation rate of over 10 airmore » changes/hour. The horses are embalmed, creating a voluminous source of formaldehyde and phenol vapors. Budget constraints and increasingly stringent exposure limits for formaldehyde presented a great challenge to design a ventilation system that yields acceptable air quality. The design solution included two innovative elements: air-to-air heat recovery, and focused ventilation.« less

  9. Physicochemistry and cardiovascular toxicity of metal fume PM2.5: a study of human coronary artery endothelial cells and welding workers

    PubMed Central

    Lai, Chane-Yu; Lai, Ching-Huang; Chuang, Hsiao-Chi; Pan, Chih-Hong; Yen, Cheng-Chieh; Lin, Wen-Yi; Chen, Jen-Kun; Lin, Lian-Yu; Chuang, Kai-Jen

    2016-01-01

    Occupational exposure to welding fumes causes a higher incidence of cardiovascular disease; however, the association remains unclear. To clarify the possible association, exposure assessment of metal fumes with an aerodynamic diameter of <2.5 μm (PM2.5) in welding and office areas was characterized in a shipyard in Taiwan. Cardiovascular toxicity caused by PM2.5 was determined in workers (in both the welding and office areas). Significant amounts of bimodal metal fume particles with count median diameters (CMDs) of 14.1~15.1 and 126.3~135.8 nm were produced in the shipyard. Metal fume PM2.5 resulted in decreased cell viability and increased levels of 8-hydroxy-2’-deoxyguanosine (8-OHdG), interleukin (IL)-6, and nitric oxide (NO) in human coronary artery epithelial cells (HCAECs). We recruited 118 welding workers and 45 office workers for a personal PM2.5 exposure assessment and determination of urinary levels of 8-OHdG, 8-iso-prostaglandin F2α (8-iso-PGF2α), and various metals. We observed that a 10-μg/m3 increase in the mean PM2.5 concentration was associated with a 2.15% increase in 8-OHdG and an 8.43% increase in 8-iso-PGF2α in welding workers. Both 8-OHdG and 8-iso-PGF2α were associated with Fe and Zn in the urine. In conclusion, metal fume PM2.5 could increase the risk of cardiovascular toxicity after inhalation. PMID:27641436

  10. Physicochemistry and cardiovascular toxicity of metal fume PM2.5: a study of human coronary artery endothelial cells and welding workers.

    PubMed

    Lai, Chane-Yu; Lai, Ching-Huang; Chuang, Hsiao-Chi; Pan, Chih-Hong; Yen, Cheng-Chieh; Lin, Wen-Yi; Chen, Jen-Kun; Lin, Lian-Yu; Chuang, Kai-Jen

    2016-09-19

    Occupational exposure to welding fumes causes a higher incidence of cardiovascular disease; however, the association remains unclear. To clarify the possible association, exposure assessment of metal fumes with an aerodynamic diameter of <2.5 μm (PM2.5) in welding and office areas was characterized in a shipyard in Taiwan. Cardiovascular toxicity caused by PM2.5 was determined in workers (in both the welding and office areas). Significant amounts of bimodal metal fume particles with count median diameters (CMDs) of 14.1~15.1 and 126.3~135.8 nm were produced in the shipyard. Metal fume PM2.5 resulted in decreased cell viability and increased levels of 8-hydroxy-2'-deoxyguanosine (8-OHdG), interleukin (IL)-6, and nitric oxide (NO) in human coronary artery epithelial cells (HCAECs). We recruited 118 welding workers and 45 office workers for a personal PM2.5 exposure assessment and determination of urinary levels of 8-OHdG, 8-iso-prostaglandin F2α (8-iso-PGF2α), and various metals. We observed that a 10-μg/m(3) increase in the mean PM2.5 concentration was associated with a 2.15% increase in 8-OHdG and an 8.43% increase in 8-iso-PGF2α in welding workers. Both 8-OHdG and 8-iso-PGF2α were associated with Fe and Zn in the urine. In conclusion, metal fume PM2.5 could increase the risk of cardiovascular toxicity after inhalation.

  11. Physicochemistry and cardiovascular toxicity of metal fume PM2.5: a study of human coronary artery endothelial cells and welding workers

    NASA Astrophysics Data System (ADS)

    Lai, Chane-Yu; Lai, Ching-Huang; Chuang, Hsiao-Chi; Pan, Chih-Hong; Yen, Cheng-Chieh; Lin, Wen-Yi; Chen, Jen-Kun; Lin, Lian-Yu; Chuang, Kai-Jen

    2016-09-01

    Occupational exposure to welding fumes causes a higher incidence of cardiovascular disease; however, the association remains unclear. To clarify the possible association, exposure assessment of metal fumes with an aerodynamic diameter of <2.5 μm (PM2.5) in welding and office areas was characterized in a shipyard in Taiwan. Cardiovascular toxicity caused by PM2.5 was determined in workers (in both the welding and office areas). Significant amounts of bimodal metal fume particles with count median diameters (CMDs) of 14.1~15.1 and 126.3~135.8 nm were produced in the shipyard. Metal fume PM2.5 resulted in decreased cell viability and increased levels of 8-hydroxy-2’-deoxyguanosine (8-OHdG), interleukin (IL)-6, and nitric oxide (NO) in human coronary artery epithelial cells (HCAECs). We recruited 118 welding workers and 45 office workers for a personal PM2.5 exposure assessment and determination of urinary levels of 8-OHdG, 8-iso-prostaglandin F2α (8-iso-PGF2α), and various metals. We observed that a 10-μg/m3 increase in the mean PM2.5 concentration was associated with a 2.15% increase in 8-OHdG and an 8.43% increase in 8-iso-PGF2α in welding workers. Both 8-OHdG and 8-iso-PGF2α were associated with Fe and Zn in the urine. In conclusion, metal fume PM2.5 could increase the risk of cardiovascular toxicity after inhalation.

  12. Altered ion transport in normal human bronchial epithelial cells following exposure to chemically distinct metal welding fume particles.

    PubMed

    Fedan, Jeffrey S; Thompson, Janet A; Meighan, Terence G; Zeidler-Erdely, Patti C; Antonini, James M

    2017-07-01

    Welding fume inhalation causes pulmonary toxicity, including susceptibility to infection. We hypothesized that airway epithelial ion transport is a target of fume toxicity, and investigated the effects of fume particulates from manual metal arc-stainless steel (MMA-SS) and gas metal arc-mild steel (GMA-MS) on ion transport in normal human bronchial epithelium (NHBE) cultured in air-interface. MMA-SS particles, more soluble than GMA-MS particles, contain Cr, Ni, Fe and Mn; GMA-MS particles contain Fe and Mn. MMA-SS or GMA-MS particles (0.0167-166.7μg/cm 2 ) were applied apically to NHBEs. After 18h transepithelial potential difference (V t ), resistance (R t ), and short circuit current (I sc ) were measured. Particle effects on Na + and Cl¯ channels and the Na + ,K + ,2Cl¯-cotransporter were evaluated using amiloride (apical), 5-nitro-2-[(3-phenylpropyl)amino]benzoic acid (NPPB, apical), and bumetanide (basolateral), respectively. MMA-SS (0.0167-16.7μg/cm 2 ) increased basal V t . Only 16.7μg/cm 2 GMA-MS increased basal V t significantly. MMA-SS or GMA-MS exposure potentiated I sc responses (decreases) to amiloride and bumetanide, while not affecting those to NPPB, GMA-MS to a lesser degree than MMA-SS. Variable effects on R t were observed in response to amiloride, and bumetanide. Generally, MMA-SS was more potent in altering responses to amiloride and bumetanide than GMA-MS. Hyperpolarization occurred in the absence of LDH release, but decreases in V t , R t , and I sc at higher fume particulate doses accompanied LDH release, to a greater extent for MMA-SS. Thus, Na + transport and Na + ,K + ,2Cl¯-cotransport are affected by fume exposure; MMA-MS is more potent than GMA-MS. Enhanced Na + absorption and decreased airway surface liquid could compromise defenses against infection. Published by Elsevier Inc.

  13. Fabrication, Characterization, and Energetic Properties of Metallized Nanofibers

    DTIC Science & Technology

    2013-12-31

    to reduce the chance of spark ignition while electrospinning, a low working voltage of 12- 15 kV, is applied to a stainless steel needle (17-27...solution as a solid block within 12-24 h. An in-house electrospinning setup in a fume hood is used to electrospin the metalized suspension equipped...rolled to obtain a cylindrical cross section along the length of the fiber. These samples were then placed inside a steel combustion chamber (48 x 48

  14. Preparation, Characterization, and Energetic Properties of Metallized Nanofibers

    DTIC Science & Technology

    2013-12-31

    applied to a stainless steel needle (17-27 gauge) thereby charging the n AI/PFPE loaded PS/ DMF suspension. The syringe pump is set at a flow rate of...front propagates to the left. rolled to obtain a cylindrical cross section along the length of the fiber. These samples were then placed inside a steel ...occur altering the transJerred mass balance during electro spinning. Fiber Spinning. An in house electrospinning setup in a fume hood is used to

  15. Effects of curing type, silica fume fineness, and fiber length on the mechanical properties and impact resistance of UHPFRC

    NASA Astrophysics Data System (ADS)

    Arel, Hasan Şahan

    The effects of silica fume fineness and fiber aspect ratio on the compressive strength and impact resistance of ultra high-performance fiber-reinforced concrete (UHPFRC) are investigated experimentally. To this end, UHPFRC mixtures are manufactured by combining silica fumes with different fineness (specific surface areas: 17,200, 20,000, and 27,600 m2/kg) and hooked-end steel fibers with various aspect ratios (lengths: 8, 13, and 16 mm). The samples are subjected to standard curing, steam curing, and hot-water curing. Compressive strength tests are conducted after 7-, 28-, 56-, and 90-day curing periods, and an impact resistance experiment is performed after the 90th day. A steam-cured mixture of silica fumes with a specific surface area of 27,600 m2/kg and 16-mm-long fibers produce better results than the other mixtures in terms of mechanical properties. Moreover, impact resistance increases with the fiber aspect ratio.

  16. Some engineering properties of heavy concrete added silica fume

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akkaş, Ayşe; Başyiğit, Celalettin; Esen, Serap

    Many different types of building materials have been used in building construction for years. Heavy concretes can be used as a building material for critical building as it can contain a mixture of many heavy elements. The barite itself for radiation shielding can be used and also in concrete to produce the workable concrete with a maximum density and adequate structural strength. In this study, some engineering properties like compressive strength, elasticity modules and flexure strength of heavy concretes’ added Silica fume have been investigated.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shehabi, Arman; Ganeshalingam, Mohan; DeMates, Lauren

    Laboratories are estimated to be 3-5 times more energy intensive than typical office buildings and offer significant opportunities for energy use reductions. Although energy intensity varies widely, laboratories are generally energy intensive due to ventilation requirements, the research instruments used, and other health and safety concerns. Because the requirements of laboratory facilities differ so dramatically from those of other buildings, a clear need exists for an initiative exclusively targeting these facilities. The building stock of laboratories in the United States span different economic sectors, include governmental and academic institution, and are often defined differently by different groups. Information on laboratorymore » buildings is often limited to a small subsection of the total building stock making aggregate estimates of the total U.S. laboratories and their energy use challenging. Previous estimates of U.S. laboratory space vary widely owing to differences in how laboratories are defined and categorized. A 2006 report on fume hoods provided an estimate of 150,000 laboratories populating the U.S. based in part on interviews of industry experts, however, a 2009 analysis of the 2003 Commercial Buildings Energy Consumption Survey (CBECS) generated an estimate of only 9,000 laboratory buildings. This report draws on multiple data sources that have been evaluated to construct an understanding of U.S. laboratories across different sizes and markets segments. This 2016 analysis is an update to draft reports released in October and December 2016.« less

  18. Exposure to Cooking Oil Fumes and Oxidative Damages: A Longitudinal Study in Chinese Military Cooks

    PubMed Central

    Lai, Ching-Huang; Jaakkola, Jouni J.K.; Chuang, Chien-Yi; Liou, Saou-Hsing; Lung, Shih-Chun; Loh, Ching-Hui; Yu, Dah-Shyong; Strickland, Paul T.

    2014-01-01

    Cooking oil fumes contain polycyclic aromatic hydrocarbons (PAHs), heterocyclic aromatic amines, benzene, and formaldehyde which may cause oxidative damages to DNA and lipids. We assessed the relations between exposure to cooking oil fumes (COF) and subsequent oxidative DNA damage and lipid peroxidation among military cooks and office-based soldiers. The study population, including 61 Taiwanese male military cooks and a reference group of 37 office soldiers, collected urine samples pre-shift of the first weekday and post-shift of the fifth workday. We measured airborne particulate PAHs in military kitchens and offices and concentrations of urinary 1-OHP, a biomarker of PAH exposure, urinary 8-hydroxydeoxyguanosine (8-OHdG), a biomarkers of oxidative DNA damage, and urinary isoprostane (Isop). Airborne particulate PAHs levels in kitchens significantly exceeded those in office areas. The concentrations of urinary 1-OHP among military cooks increased significantly after 5 days of exposure to COF. Using generalized estimating equation (GEE) analysis adjusting for confounding, a change in log(8-OHdG) and log(Isop) were statistically significantly related to a unit change in log(1-OHP) (regression coefficient [β], β= 0.06, 95% CI 0.001 to 0.12) and (β= 0.07, 95% CI 0.001 to 0.13), respectively. Exposure to PAHs, or other compounds in cooking-oil fumes, may cause both oxidative DNA damage and lipid peroxidation. PMID:22968348

  19. A review of Brucella infection in marine mammals, with special emphasis on Brucella pinnipedialis in the hooded seal (Cystophora cristata)

    PubMed Central

    2011-01-01

    Brucella spp. were isolated from marine mammals for the first time in 1994. Two novel species were later included in the genus; Brucella ceti and Brucella pinnipedialis, with cetaceans and seals as their preferred hosts, respectively. Brucella spp. have since been isolated from a variety of marine mammals. Pathological changes, including lesions of the reproductive organs and associated abortions, have only been registered in cetaceans. The zoonotic potential differs among the marine mammal Brucella strains. Many techniques, both classical typing and molecular microbiology, have been utilised for characterisation of the marine mammal Brucella spp. and the change from the band-based approaches to the sequence-based approaches has greatly increased our knowledge about these strains. Several clusters have been identified within the B. ceti and B. pinnipedialis species, and multiple studies have shown that the hooded seal isolates differ from other pinniped isolates. We describe how different molecular methods have contributed to species identification and differentiation of B. ceti and B. pinnipedialis, with special emphasis on the hooded seal isolates. We further discuss the potential role of B. pinnipedialis for the declining Northwest Atlantic hooded seal population. PMID:21819589

  20. EFFECT OF AN ACUTE EXPOSURE TO MOLINATE ON OVULATION IN THE LONG-EVANS HOODED RAT

    EPA Science Inventory

    EFFECT OF AN ACUTE EXPOSURE TO MOLINATE ON OVULATION IN THE LONG-EVANS HOODED RAT. T E Stoker, D L Guidici, S C Jeffay, W K McElroy, S D Perreault and R L Cooper. Reproductive Toxicology Division, NHEERL, ORD, US EPA, RTP, NC. Sponsor: RJ Kavlock.
    Molinate, a thiocarbamate ...