Sample records for laboratory inel low-level

  1. (Low-level radioactive waste management techniques)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Hoesen, S.D.; Kennerly, J.M.; Williams, L.C.

    1988-08-08

    The US team consisting of representatives of Oak Ridge National Laboratory (ORNL), Savannah River plant (SRP), Idaho National Engineering Laboratory (INEL), and the Department of Energy, Oak Ridge Operations participated in a training program on French low-level radioactive waste (LLW) management techniques. Training in the rigorous waste characterization, acceptance and certification procedures required in France was provided at Agence Nationale pour les Gestion des Dechets Radioactif (ANDRA) offices in Paris.

  2. INEL BNCT Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ackermann, A.L.

    1991-08-01

    This Bulletin presents a summary of accomplishments and highlights in the Idaho National Engineering Laboratory's (INEL) Boron Neutron Capture Therapy (BNCT) Program for August 1991. This bulletin includes information on the brain tumor and melanoma research programs, Power Burst Facility (PBF) technical support and modifications, PBF operations, and updates to the animal data charts.

  3. Idaho National Engineering Laboratory High-Level Waste Roadmap. Revision 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-08-01

    The Idaho National Engineering Laboratory (INEL) High-Level Waste (HLW) Roadmap takes a strategic look at the entire HLW life-cycle starting with generation, through interim storage, treatment and processing, transportation, and on to final disposal. The roadmap is an issue-based planning approach that compares ``where we are now`` to ``where we want and need to be.`` The INEL has been effectively managing HLW for the last 30 years. Calcining operations are continuing to turn liquid HLW into a more manageable form. Although this document recognizes problems concerning HLW at the INEL, there is no imminent risk to the public or environment.more » By analyzing the INEL current business operations, pertinent laws and regulations, and committed milestones, the INEL HLW Roadmap has identified eight key issues existing at the INEL that must be resolved in order to reach long-term objectives. These issues are as follows: A. The US Department of Energy (DOE) needs a consistent policy for HLW generation, handling, treatment, storage, and disposal. B. The capability for final disposal of HLW does not exist. C. Adequate processes have not been developed or implemented for immobilization and disposal of INEL HLW. D. HLW storage at the INEL is not adequate in terms of capacity and regulatory requirements. E. Waste streams are generated with limited consideration for waste minimization. F. HLW is not adequately characterized for disposal nor, in some cases, for storage. G. Research and development of all process options for INEL HLW treatment and disposal are not being adequately pursued due to resource limitations. H. HLW transportation methods are not selected or implemented. A root-cause analysis uncovered the underlying causes of each of these issues.« less

  4. Snake River Plain FORGE Well Data for INEL-1

    DOE Data Explorer

    Robert Podgorney

    1979-03-01

    Well data for the INEL-1 well located in eastern Snake River Plain, Idaho. This data collection includes caliper logs, lithology reports, borehole logs, temperature at depth data, neutron density and gamma data, full color logs, fracture analysis, photos, and rock strength parameters for the INEL-1 well. This collection of data has been assembled as part of the site characterization data used to develop the conceptual geologic model for the Snake River Plain site in Idaho, as part of phase 1 of the Frontier Observatory for Research in Geothermal Energy (FORGE) initiative. They were assembled by the Snake River Geothermal Consortium (SRGC), a team of collaborators that includes members from national laboratories, universities, industry, and federal agencies, lead by the Idaho National Laboratory (INL).

  5. INEL BNCT Program: Volume 5, No. 9

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ackermann, A.L.

    1991-01-01

    This Bulletin presents a summary of accomplishments and highlights of the Idaho National Engineering Laboratory's (INEL) Boron Neutron Capture Therapy (BNCT) Program for September 1991. This bulletin includes information on the brain tumor and melanoma research programs, Power Burst Facility (PBF) technical support and modifications, PBF operations, and updates to the animal data charts.

  6. INEL BNCT Program: Volume 5, No. 9. Bulletin, September 1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ackermann, A.L.

    1991-12-31

    This Bulletin presents a summary of accomplishments and highlights of the Idaho National Engineering Laboratory`s (INEL) Boron Neutron Capture Therapy (BNCT) Program for September 1991. This bulletin includes information on the brain tumor and melanoma research programs, Power Burst Facility (PBF) technical support and modifications, PBF operations, and updates to the animal data charts.

  7. INEL Spray-forming Research

    NASA Technical Reports Server (NTRS)

    Mchugh, Kevin M.; Key, James F.

    1993-01-01

    Spray forming is a near-net-shape fabrication technology in which a spray of finely atomized liquid droplets is deposited onto a suitably shaped substrate or mold to produce a coherent solid. The technology offers unique opportunities for simplifying materials processing without sacrificing, and oftentimes substantially improving, product quality. Spray forming can be performed with a wide range of metals and nonmetals, and offers property improvements resulting from rapid solidification (e.g., refined microstructures, extended solid solubilities and reduced segregation). Economic benefits result from process simplification and the elimination of unit operations. Researchers at the Idaho National Engineering Laboratory (INEL) are developing spray-forming technology for producing near-net-shape solids and coatings of a variety of metals, polymers, and composite materials. Results from several spray forming programs are presented to illustrate the range of capabilities of the technique as well as the accompanying technical and economic benefits. Low-carbon steel strip greater than 0.75 mm thick and polymer membranes for gas/gas and liquid/liquid separations that were spray formed are discussed; recent advances in spray forming molds, dies, and other tooling using low-melting-point metals are described.

  8. INEL BNCT Research Program, March/April 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Venhuizen, J.R.

    1992-09-01

    This report presents summaries for two months of current research for the Idaho National Engineering Laboratory (INEL) Boron Neutron Capture Therapy (BNCT) Program. Information is presented on development and murino screening experiments of low-density lipoprotein, carboranyl alanine, and liposome boron containing compounds. Pituitary tumor call culture studies are described. Drug stability, pharmacology and toxicity evaluation of borocaptate sodium (BSH) and boronopheoylalanine (BPA) are described. Treatment protocol development via the large animal (canine) model studies and physiological response evaluation in rats are discussed. Supporting technology development and technical support activities for boron drug biochemistry and purity, analytical and measurement dosimetry, andmore » noninvasive boron quantification activities are included for the current time period. Current publications for the two months are listed.« less

  9. 138. ARAII Building ARA606 floor plan for remodel as Inel ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    138. ARA-II Building ARA-606 floor plan for remodel as Inel Welding Laboratory. Shows room divisions and welding stations to be installed. Aerojet Nuclear Company 1375-ARA-II-606-E-2. Date: June 1976. Ineel index code no. 070-0606-10-400-156552. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  10. A document review to characterize Atomic International SNAP fuels shipped to INEL 1966--1973

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wahnschaffe, S.D.; Lords, R.E.; Kneff, D.W.

    1995-09-01

    This report provides the results of a document search and review study to obtain information on the spent fuels for the following six Nuclear Auxiliary Power (SNAP) reactor cores now stored at the Idaho National Engineering Laboratory (INEL): SNAP-2 Experimental Reactor, SNAP-2 Development Reactor, SNAP-10A Ground Test Reactor, SNAP-8 Experimental Reactor, SNAP-8 Development Reactor, and Shield Test Reactor. The report also covers documentation on SNAP fuel materials from four in-pile materials tests: NAA-82-1, NAA-115-2, NAA-117-1, and NAA-121. Pieces of these fuel materials are also stored at INEL as part of the SNAP fuel shipments.

  11. Chlorine-36 in the Snake River Plain Aquifer at the Idaho National Engineering Laboratory; origin and implications

    USGS Publications Warehouse

    Beasley, T.M.; Cecil, L.D.; Sharma, P.; Kubik, P.W.; Fehn, U.; Mann, L.J.; Gove, H.E.

    1993-01-01

    Between 1952 and 1984, low-level radioactive waste was introduced directly into the Snake River Plain aquifer at the Idaho National Engineering Laboratory (INEL), Idaho Falls, Idaho. These wastes were generated, principally, at the nuclear fuel reprocessing facility on the site. Our measurements of 36C1 in monitoring and production well waters, downgradient from disposal wells and seepage ponds, found easily detectable, nonhazardous concentrations of this radionuclide from the point of injection to the INEL southern site boundary. Comparisons are made between 3H and 36Cl concentrations in aquifer water and the advantages of 36C1 as a tracer of subsurface-water dynamics at the site are discussed.

  12. An overview of environmental surveillance of waste management activities at the Idaho National Engineering Laboratory

    USGS Publications Warehouse

    Smith, T.H.; Chew, E.W.; Hedahl, T.G.; Mann, L.J.; Pointer, T.F.; Wiersma, G.B.

    1986-01-01

    The Idaho National Engineering Laboratory (INEL), in southeastern Idaho, is a principal center for nuclear energy development for the Department of Energy (DOE) and the U.S. Nuclear Navy. Fifty-two reactors have been built at the INEL, with 15 still operable. Extensive environmental surveillance is conducted at the INEL by DOE's Radiological Environmental Sciences Laboratory (RESL), and the U.S. Geological Survey (USGS), the National Oceanic and Atmospheric Administration (NOAA), EG&G Idaho, Inc., and Westinghouse Idaho Nuclear Company (WINCO). Surveillance of waste management facilities radiation is integrated with the overall INEL Site surveillance program. Air, warer, soil, biota, and environmental radiation are monitored or sampled routinely at INEL. Results to date indicate very small or no impacts from INEL on the surrounding environment. Environmental surveillance activities are currently underway to address key environmental issues at the INEL.

  13. 1995 Laboratory-Directed Research and Development Annual report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cauffman, D.P.; Shoaf, D.L.; Hill, D.A.

    1995-12-31

    The Laboratory-Directed Research and Development Program (LDRD) is a key component of the discretionary research conducted by Lockheed Idaho Technologies Company (Lockheed Idaho) at the Idaho National Engineering Laboratory (INEL). The threefold purpose and goal of the LDRD program is to maintain the scientific and technical vitality of the INEL, respond to and support new technical opportunities, and enhance the agility and flexibility of the national laboratory and Lockheed Idaho to address the current and future missions of the Department of Energy.

  14. LPT. Low power test control building (TAN641) east facade. Sign ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. Low power test control building (TAN-641) east facade. Sign says "Energy and Systems Technology Laboratory, INEL" (Post-ANP-use). Camera facing west. INEEL negative no. HD-40-3-2 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  15. Idaho National Engineering Laboratory Waste Management Operations Roadmap Document

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bullock, M.

    1992-04-01

    At the direction of the Department of Energy-Headquarters (DOE-HQ), the DOE Idaho Field Office (DOE-ID) is developing roadmaps for Environmental Restoration and Waste Management (ER&WM) activities at Idaho National Engineering Laboratory (INEL). DOE-ID has convened a select group of contractor personnel from EG&G Idaho, Inc. to assist DOE-ID personnel with the roadmapping project. This document is a report on the initial stages of the first phase of the INEL`s roadmapping efforts.

  16. 38. DETAIL OF CYLINDER LEVELING SYSTEM SHOWING TYPICAL UPPER AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    38. DETAIL OF CYLINDER LEVELING SYSTEM SHOWING TYPICAL UPPER AND LOWER PULLEY BRACKET. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-S-8. INEL INDEX CODE - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  17. Project Management Plan for the Idaho National Engineering Laboratory Waste Isolation Pilot Plant Experimental Test Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Connolly, M.J.; Sayer, D.L.

    1993-11-01

    EG&G Idaho, Inc. and Argonne National Laboratory-West (ANL-W) are participating in the Idaho National Engineering Laboratory`s (INEL`s) Waste Isolation Pilot Plant (WIPP) Experimental Test Program (WETP). The purpose of the INEL WET is to provide chemical, physical, and radiochemical data on transuranic (TRU) waste to be stored at WIPP. The waste characterization data collected will be used to support the WIPP Performance Assessment (PA), development of the disposal No-Migration Variance Petition (NMVP), and to support the WIPP disposal decision. The PA is an analysis required by the Code of Federal Regulations (CFR), Title 40, Part 191 (40 CFR 191), whichmore » identifies the processes and events that may affect the disposal system (WIPP) and examines the effects of those processes and events on the performance of WIPP. A NMVP is required for the WIPP by 40 CFR 268 in order to dispose of land disposal restriction (LDR) mixed TRU waste in WIPP. It is anticipated that the detailed Resource Conservation and Recovery Act (RCRA) waste characterization data of all INEL retrievably-stored TRU waste to be stored in WIPP will be required for the NMVP. Waste characterization requirements for PA and RCRA may not necessarily be identical. Waste characterization requirements for the PA will be defined by Sandia National Laboratories. The requirements for RCRA are defined in 40 CFR 268, WIPP RCRA Part B Application Waste Analysis Plan (WAP), and WIPP Waste Characterization Program Plan (WWCP). This Project Management Plan (PMP) addresses only the characterization of the contact handled (CH) TRU waste at the INEL. This document will address all work in which EG&G Idaho is responsible concerning the INEL WETP. Even though EG&G Idaho has no responsibility for the work that ANL-W is performing, EG&G Idaho will keep a current status and provide a project coordination effort with ANL-W to ensure that the INEL, as a whole, is effectively and efficiently completing the requirements

  18. Undergraduate Student Attitudes and Perceptions toward Low- and High-Level Inquiry Exercise Physiology Teaching Laboratory Experiences

    ERIC Educational Resources Information Center

    Henige, Kim

    2011-01-01

    The purpose of this investigation was to compare student attitudes toward two different science laboratory learning experiences, specifically, traditional, cookbook-style, low-inquiry level (LL) activities and a high-inquiry level (HL) investigative project. In addition, we sought to measure and compare students' science-related attitudes and…

  19. Environmental resource document for the Idaho National Engineering Laboratory. Volume 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Irving, J.S.

    This document contains information related to the environmental characterization of the Idaho National Engineering Laboratory (INEL). The INEL is a major US Department of Energy facility in southeastern Idaho dedicated to nuclear research, waste management, environmental restoration, and other activities related to the development of technology. Environmental information covered in this document includes land, air, water, and ecological resources; socioeconomic characteristics and land use; and cultural, aesthetic, and scenic resources.

  20. Baseline tests for arc melter vitrification of INEL buried wastes. Volume II: Baseline test data appendices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oden, L.L.; O`Conner, W.K.; Turner, P.C.

    1993-11-19

    This report presents field results and raw data from the Buried Waste Integrated Demonstration (BWID) Arc Melter Vitrification Project Phase 1 baseline test series conducted by the Idaho National Engineering Laboratory (INEL) in cooperation with the U.S. Bureau of Mines (USBM). The baseline test series was conducted using the electric arc melter facility at the USBM Albany Research Center in Albany, Oregon. Five different surrogate waste feed mixtures were tested that simulated thermally-oxidized, buried, TRU-contaminated, mixed wastes and soils present at the INEL. The USBM Arc Furnace Integrated Waste Processing Test Facility includes a continuous feed system, the arc meltingmore » furnace, an offgas control system, and utilities. The melter is a sealed, 3-phase alternating current (ac) furnace approximately 2 m high and 1.3 m wide. The furnace has a capacity of 1 metric ton of steel and can process as much as 1,500 lb/h of soil-type waste materials. The surrogate feed materials included five mixtures designed to simulate incinerated TRU-contaminated buried waste materials mixed with INEL soil. Process samples, melter system operations data and offgas composition data were obtained during the baseline tests to evaluate the melter performance and meet test objectives. Samples and data gathered during this program included (a) automatically and manually logged melter systems operations data, (b) process samples of slag, metal and fume solids, and (c) offgas composition, temperature, velocity, flowrate, moisture content, particulate loading and metals content. This report consists of 2 volumes: Volume I summarizes the baseline test operations. It includes an executive summary, system and facility description, review of the surrogate waste mixtures, and a description of the baseline test activities, measurements, and sample collection. Volume II contains the raw test data and sample analyses from samples collected during the baseline tests.« less

  1. The status of soil mapping for the Idaho National Engineering Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Olson, G.L.; Lee, R.D.; Jeppesen, D.J.

    This report discusses the production of a revised version of the general soil map of the 2304-km{sup 2} (890-mi{sup 2}) Idaho National Engineering Laboratory (INEL) site in southeastern Idaho and the production of a geographic information system (GIS) soil map and supporting database. The revised general soil map replaces an INEL soil map produced in 1978 and incorporates the most current information on INEL soils. The general soil map delineates large soil associations based on National Resources Conservation Services [formerly the Soil Conservation Service (SCS)] principles of soil mapping. The GIS map incorporates detailed information that could not be presentedmore » on the general soil map and is linked to a database that contains the soil map unit descriptions, surficial geology codes, and other pertinent information.« less

  2. Baseline tests for arc melter vitrification of INEL buried wastes. Volume 1: Facility description and summary data report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oden, L.L.; O`Connor, W.K.; Turner, P.C.

    1993-11-19

    This report presents field results and raw data from the Buried Waste Integrated Demonstration (BWID) Arc Melter Vitrification Project Phase 1 baseline test series conducted by the Idaho National Engineering Laboratory (INEL) in cooperation with the U.S. Bureau of Mines (USBM). The baseline test series was conducted using the electric arc melter facility at the USBM Albany Research Center in Albany, Oregon. Five different surrogate waste feed mixtures were tested that simulated thermally-oxidized, buried, TRU-contaminated, mixed wastes and soils present at the INEL. The USBM Arc Furnace Integrated Waste Processing Test Facility includes a continuous feed system, the arc meltingmore » furnace, an offgas control system, and utilities. The melter is a sealed, 3-phase alternating current (ac) furnace approximately 2 m high and 1.3 m wide. The furnace has a capacity of 1 metric ton of steel and can process as much as 1,500 lb/h of soil-type waste materials. The surrogate feed materials included five mixtures designed to simulate incinerated TRU-contaminated buried waste materials mixed with INEL soil. Process samples, melter system operations data and offgas composition data were obtained during the baseline tests to evaluate the melter performance and meet test objectives. Samples and data gathered during this program included (a) automatically and manually logged melter systems operations data, (b) process samples of slag, metal and fume solids, and (c) offgas composition, temperature, velocity, flowrate, moisture content, particulate loading and metals content. This report consists of 2 volumes: Volume I summarizes the baseline test operations. It includes an executive summary, system and facility description, review of the surrogate waste mixtures, and a description of the baseline test activities, measurements, and sample collection. Volume II contains the raw test data and sample analyses from samples collected during the baseline tests.« less

  3. Subsurface information from eight wells drilled at the Idaho National Engineering Laboratory, southeastern Idaho

    USGS Publications Warehouse

    Goldstein, F.J.; Weight, W.D.

    1982-01-01

    The Idaho National Engineering Laboratory (INEL) covers about 890 square miles of the eastern Snake River Plain, in southeastern Idaho. The eastern Snake River Plain is a structural basin which has been filled with thin basaltic lava flows, rhyolitic deposits, and interbedded sediments. These rocks form an extensive ground-water reservoir known as the Snake River Plain aquifer. Six wells were drilled and two existing wells were deepened at the INEL from 1969 through 1974. Interpretation of data from the drilling program confirms that the subsurface is dominated by basalt flows interbedded with layers of sediment, cinders, and silicic volcanic rocks. Water levels in the wells show cyclic seasonal fluctuations of maximum water levels in winter and minimum water levels in mid-summer. Water levels in three wells near the Big Lost River respond to changes in recharge to the Snake River Plain aquifer from the Big Lost River. Measured water levels in multiple piezometers in one well indicate increasing pressure heads with depth. A marked decline in water levels in the wells since 1977 is attributed to a lack of recharge to the Snake River Plain aquifer.

  4. Environmental evaluation of alternatives for long-term management of Defense high-level radioactive wastes at the Idaho Chemical Processing Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1982-09-01

    The U.S. Department of Energy (DOE) is considering the selection of a strategy for the long-term management of the defense high-level wastes at the Idaho Chemical Processing Plant (ICPP). This report describes the environmental impacts of alternative strategies. These alternative strategies include leaving the calcine in its present form at the Idaho National Engineering Laboratory (INEL), or retrieving and modifying the calcine to a more durable waste form and disposing of it either at the INEL or in an offsite repository. This report addresses only the alternatives for a program to manage the high-level waste generated at the ICPP. 24more » figures, 60 tables.« less

  5. Hydrologic conditions and distribution of selected radiochemical and chemical constituents in water, Snake River Plain aquifer, Idaho National Engineering Laboratory, Idaho, 1989 through 1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bartholomay, R.C.; Orr, B.R.; Liszewski, M.J.

    Radiochemical and chemical wastewater discharged since 1952 to infiltration ponds and disposal wells at the Idaho National Engineering Laboratory (INEL) has affected water quality in the Snake River Plain aquifer. The U.S. Geological Survey, in cooperation with the U.S. Department of Energy, maintains a continuous monitoring network at the INEL to determine hydrologic trends and to delineate the movement of radiochemical and chemical wastes in the aquifer. This report presents an analysis of water-level and water-quality data collected from the Snake River Plain aquifer during 1989-91. Water in the eastern Snake River Plain aquifer moves principally through fractures and interflowmore » zones in basalt, generally flows southwestward, and eventually discharges at springs along the Snake River. The aquifer is recharged principally from irrigation water, infiltration of streamflow, and ground-water inflow from adjoining mountain drainage basins. Water levels in wells throughout the INEL generally declined during 1989-91 due to drought. Detectable concentrations of radiochemical constituents in water samples from wells in the Snake River Plain aquifer at the INEL decreased or remained constant during 1989-91. Decreased concentrations are attributed to reduced rates of radioactive-waste disposal, sorption processes, radioactive decay, and changes in waste-disposal practices. Detectable concentrations of chemical constituents in water from the Snake River Plain aquifer at the INEL were variable during 1989-91. Sodium and chloride concentrations in the southern part of the INEL increased slightly during 1989-91 because of increased waste-disposal rates and a lack of recharge from the Big Lost River. Plumes of 1,1,1-trichloroethane have developed near the Idaho Chemical Processing Plant and the Radioactive Waste Management Complex as a result of waste disposal practices.« less

  6. The Idaho National Engineering Laboratory Site environmental report for calendar Year 1990

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoff, D.L.; Mitchell, R.G.; Moore, R.

    1991-06-01

    The results of the various monitoring programs for 1990 indicate that most radioactivity from the Idaho National Engineering Laboratory (INEL) operations could not be distinguished from worldwide fallout and natural radioactivity in the region surrounding the INEL Site. Although some radioactive materials were discharged during Site operations, concentrations and doses to the surrounding population were of no health consequence and were far less than State of Idaho and Federal health protection guidelines. The first section of the report summarizes Calendar Year 1990 and January 1 through April 1, 1991, INEL activities related to compliance with environmental regulations and laws. Themore » balance of the report describes the surveillance program, the collection of foodstuffs at the INEL boundary and distant offsite locations, and the collection of air and water samples at onsite locations and offsite boundary and distant locations. The report also compares and evaluates the sample results and discusses implications, if any. Nonradioactive and radioactive effluent monitoring at the Site, and the US Geological Survey (USGS) ground-water monitoring program are also summarized. 33 refs., 18 figs., 29 tabs.« less

  7. Storage for greater-than-Class C low-level radioactive waste

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beitel, G.A.

    1991-12-31

    EG and G Idaho, Inc., at the Idaho National Engineering Laboratory (INEL) is actively pursuing technical storage alternatives for greater-than-Class C low-level radioactive waste (GTCC LLW) until a suitable licensed disposal facility is operating. A recently completed study projects that between 2200 and 6000 m{sup 3} of GTCC LLW will be generated by the year 2035; the base case estimate is 3250 m{sup 3}. The current plan envisions a disposal facility available as early as the year 2010. A long-term dedicated storage facility could be available in 1997. In the meantime, it is anticipated that a limited number of sealedmore » sources that are no longer useful and have GTCC concentrations of radionuclides will require storage. Arrangements are being made to provide this interim storage at an existing DOE waste management facility. All interim stored waste will subsequently be moved to the dedicated storage facility once it is operating. Negotiations are under way to establish a host site for interim storage, which may be operational, at the earliest, by the second quarter of 1993. Two major activities toward developing a long-term dedicated storage facility are ongoing. (a) An engineering study, which explores costs for alternatives to provide environmentally safe storage and satisfy all regulations, is being prepared. Details of some of the findings of that study will be presented. (b) There is also an effort under way to seek the assistance of one or more private companies in providing dedicated storage. Alternatives and options will be discussed.« less

  8. Digital conversion of INEL archeological data using ARC/INFO and Oracle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, R.D.; Brizzee, J.; White, L.

    1993-11-04

    This report documents the procedures used to convert archaeological data for the INEL to digital format, lists the equipment used, and explains the verification and validation steps taken to check data entry. It also details the production of an engineered interface between ARC/INFO and Oracle.

  9. User`s and reference guide to the INEL RML/analytical radiochemistry sample tracking database version 1.00

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Femec, D.A.

    This report discusses the sample tracking database in use at the Idaho National Engineering Laboratory (INEL) by the Radiation Measurements Laboratory (RML) and Analytical Radiochemistry. The database was designed in-house to meet the specific needs of the RML and Analytical Radiochemistry. The report consists of two parts, a user`s guide and a reference guide. The user`s guide presents some of the fundamentals needed by anyone who will be using the database via its user interface. The reference guide describes the design of both the database and the user interface. Briefly mentioned in the reference guide are the code-generating tools, CREATE-SCHEMAmore » and BUILD-SCREEN, written to automatically generate code for the database and its user interface. The appendices contain the input files used by the these tools to create code for the sample tracking database. The output files generated by these tools are also included in the appendices.« less

  10. LAFARA: a new underground laboratory in the French Pyrénées for ultra low-level gamma-ray spectrometry.

    PubMed

    van Beek, P; Souhaut, M; Lansard, B; Bourquin, M; Reyss, J-L; von Ballmoos, P; Jean, P

    2013-02-01

    We describe a new underground laboratory, namely LAFARA (for "LAboratoire de mesure des FAibles RAdioactivités"), that was recently created in the French Pyrénées. This laboratory is primarily designed to analyze environmental samples that display low radioactivity levels using gamma-ray spectrometry. Two high-purity germanium detectors were placed under 85 m of rock (ca. 215 m water equivalent) in the tunnel of Ferrières (Ariège, France). The background is thus reduced by a factor of ∼20 in comparison to above-ground laboratories. Both detectors are fully equipped so that the samples can be analyzed in an automatic mode without requiring permanent presence of a technician in the laboratory. Auto-samplers (twenty positions) and systems to fill liquid nitrogen automatically provide one month of autonomy to the spectrometers. The LAFARA facility allows us to develop new applications in the field of environmental sciences based on the use of natural radionuclides present at low levels in the environment. As an illustration, we present two of these applications: i) dating of marine sediments using the decay of (226)Ra in sedimentary barite (BaSO(4)), ii) determination of (227)Ac ((231)Pa) activities in marine sediment cores. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. A layered approach to technology transfer of AVIRIS between Earth Search Sciences, Inc. and the Idaho National Engineering Laboratory

    NASA Technical Reports Server (NTRS)

    Ferguson, James S.; Ferguson, Joanne E.; Peel, John, III; Vance, Larry

    1995-01-01

    Since initial contact between Earth Search Sciences, Inc. (ESSI) and the Idaho National Engineering Laboratory (INEL) in February, 1994, at least seven proposals have been submitted in response to a variety of solicitations to commercialize and improve the AVIRIS instrument. These proposals, matching ESSI's unique position with respect to agreements with the National Aeronautics and Space Administration (NASA) and the Jet Propulsion Laboratory (JPL) to utilize, miniaturize, and commercialize the AVIRIS instrument and platform, are combined with the applied engineering of the INEL. Teaming ESSI, NASA/JPL, and INEL with diverse industrial partners has strengthened the respective proposals. These efforts carefully structure the overall project plans to ensure the development, demonstration, and deployment of this concept to the national and international arenas. The objectives of these efforts include: (1) developing a miniaturized commercial, real-time, cost effective version of the AVIRIS instrument; (2) identifying multiple users for AVIRIS; (3) integrating the AVIRIS technology with other technologies; (4) gaining the confidence/acceptance of other government agencies and private industry in AVIRIS; and (5) increasing the technology base of U.S. industry.

  12. Design and implementation of the protective cap/biobarrier experiment at the Idaho National Engineering Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Limbach, W.E.; Ratzlaff, T.D.; Anderson, J.E.

    1994-12-31

    The Protective Cap/Biobarrier Experiment (PCBE), initiated in 1993 at the Idaho National Engineering Laboratory (INEL), is a strip-split plot experiment with three replications designed to rigorously test a 2.0-m loessal soil cap against a cap recommended by the US Environmental Protection Agency and two caps with biological intrusion barriers. Past research at INEL indicates that it should be possible to exclude water from buried wastes using natural materials and natural processes in arid environments rather than expensive materials (geotextiles) and highly engineered caps. The PCBE will also test the effects of two vegetal covers and three irrigation levels on capmore » performance. Drainage pans, located at the bottom of each plot, will monitor cap failure. Soil water profiles will be monitored biweekly by neutron probe and continuously by time domain reflectometry. The performance of each cap design will be monitored under a variety of conditions through 1998. From 1994 to 1996, the authors will assess plant establishment, rooting depths, patterns of moisture extraction and their interactions among caps, vegetal covers, and irrigation levels. In 1996, they will introduce ants and burrowing mammals to test the structural integrity of each cap design. In 1998, the authors will apply sufficient water to determine the failure limit for each cap design. The PCBE should provide reliable knowledge of the performances of the four cap designs under a variety of conditions and aid in making hazardous-waste management decisions at INEL and at disposal sites in similar environments.« less

  13. Final Environmental Impact Statement for Treating Transuranic (TRU)/Alpha Low-level Waste at the Oak Ridge National Laboratory Oak Ridge, Tennessee

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    N /A

    2000-06-30

    The DOE proposes to construct, operate, and decontaminate/decommission a TRU Waste Treatment Facility in Oak Ridge, Tennessee. The four waste types that would be treated at the proposed facility would be remote-handled TRU mixed waste sludge, liquid low-level waste associated with the sludge, contact-handled TRU/alpha low-level waste solids, and remote-handled TRU/alpha low-level waste solids. The mixed waste sludge and some of the solid waste contain metals regulated under the Resource Conservation and Recovery Act and may be classified as mixed waste. This document analyzes the potential environmental impacts associated with five alternatives--No Action, the Low-Temperature Drying Alternative (Preferred Alternative), themore » Vitrification Alternative, the Cementation Alternative, and the Treatment and Waste Storage at Oak Ridge National Laboratory (ORNL) Alternative.« less

  14. Compliance program data management system for The Idaho National Engineering Laboratory/Environmental Protection Agency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hertzler, C.L.; Poloski, J.P.; Bates, R.A.

    1988-01-01

    The Compliance Program Data Management System (DMS) developed at the Idaho National Engineering Laboratory (INEL) validates and maintains the integrity of data collected to support the Consent Order and Compliance Agreement (COCA) between the INEL and the Environmental Protection Agency (EPA). The system uses dBase III Plus programs and dBase III Plus in an interactive mode to enter, store, validate, manage, and retrieve analytical information provided on EPA Contract Laboratory Program (CLP) forms and CLP forms modified to accommodate 40 CFR 264 Appendix IX constituent analyses. Data analysis and presentation is performed utilizing SAS, a statistical analysis software program. Archivingmore » of data and results is performed at appropriate stages of data management. The DMS is useful for sampling and analysis programs where adherence to EPA CLP protocol, along with maintenance and retrieval of waste site investigation sampling results is desired or requested. 3 refs.« less

  15. GIS analysis of the siting criteria for the Mixed and Low-Level Waste Treatment Facility and the Idaho Waste Processing Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoskinson, R.L.

    1994-01-01

    This report summarizes a study conducted using the Arc/Info{reg_sign} geographic information system (GIS) to analyze the criteria used for site selection for the Mixed and Low-Level Waste Treatment Facility (MLLWTF) and the Idaho Waste Processing Facility (IWPF). The purpose of the analyses was to determine, based on predefined criteria, the areas on the INEL that best satisfied the criteria. The coverages used in this study were produced by importing the AutoCAD files that produced the maps for a pre site selection draft report into the GIS. The files were then converted to Arc/Info{reg_sign} GIS format. The initial analysis was mademore » by considering all of the criteria as having equal importance in determining the areas of the INEL that would best satisfy the requirements. Another analysis emphasized four of the criteria as ``must`` criteria which had to be satisfied. Additional analyses considered other criteria that were considered for, but not included in the predefined criteria. This GIS analysis of the siting criteria for the IWPF and MLLWTF provides a logical, repeatable, and defensible approach to the determination of candidate locations for the facilities. The results of the analyses support the location of the Candidate Locations.« less

  16. Shielding concepts for low-background proportional counter arrays in surface laboratories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aalseth, Craig E.; Humble, Paul H.; Mace, Emily K.

    2016-02-01

    Development of ultra low background gas proportional counters has made the contribution from naturally occurring radioactive isotopes – primarily and activity in the uranium and thorium decay chains – inconsequential to instrumental sensitivity levels when measurements are performed in above ground surface laboratories. Simple lead shielding is enough to mitigate against gamma rays as gas proportional counters are already relatively insensitive to naturally occurring gamma radiation. The dominant background in these surface laboratory measurements using ultra low background gas proportional counters is due to cosmic ray generated muons, neutrons, and protons. Studies of measurements with ultra low background gas proportionalmore » counters in surface and underground laboratories as well as radiation transport Monte Carlo simulations suggest a preferred conceptual design to achieve the highest possible sensitivity from an array of low background gas proportional counters when operated in a surface laboratory. The basis for a low background gas proportional counter array and the preferred shielding configuration is reported, especially in relation to measurements of radioactive gases having low energy decays such as 37Ar.« less

  17. Uncertainty analysis for low-level radioactive waste disposal performance assessment at Oak Ridge National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, D.W.; Yambert, M.W.; Kocher, D.C.

    1994-12-31

    A performance assessment of the operating Solid Waste Storage Area 6 (SWSA 6) facility for the disposal of low-level radioactive waste at the Oak Ridge National Laboratory has been prepared to provide the technical basis for demonstrating compliance with the performance objectives of DOE Order 5820.2A, Chapter 111.2 An analysis of the uncertainty incorporated into the assessment was performed which addressed the quantitative uncertainty in the data used by the models, the subjective uncertainty associated with the models used for assessing performance of the disposal facility and site, and the uncertainty in the models used for estimating dose and humanmore » exposure. The results of the uncertainty analysis were used to interpret results and to formulate conclusions about the performance assessment. This paper discusses the approach taken in analyzing the uncertainty in the performance assessment and the role of uncertainty in performance assessment.« less

  18. Could Alerting Physicians for Low Alkaline Phosphatase Levels Be Helpful in Early Diagnosis of Hypophosphatasia?

    PubMed

    Deeb, Asma; Elfatih, Abubaker

    2018-03-01

    Hypophosphatasia (HPP) is an inborn error of metabolism with significant morbidity and mortality. Its presentation is nonspecific leading to delayed or missed diagnosis. Low alkaline phosphatase (ALP) is a diagnostic test. Unlike high ALP, low level is commonly not flagged by laboratories as abnormal. A new treatment was shown to be effective in HPP. In this study we aimed to establish the frequency of low ALP levels requiring notification to physicians by the laboratory and also to describe the clinical manifestations of patients presenting with low ALP for a possible diagnosis of HPP. Patients under age 18 years with low ALP levels were identified from biochemistry records over a period of 6 months. Reference ranges were used as per the Associated Regional and University Pathologists Reference Laboratory (Utah, USA). Electronic results for patients with low levels were checked for flagging as abnormal/low ALP results. Charts of identified patients were reviewed. Presenting features were categorized under groups of disorders. ALP levels were tested in 2890 patients. 702 had values less than 160 U/L. Of these patients, 226 (32%) had age/gender specific low ALP. None of the low ALP results was flagged as low. Twenty-one had more than one low reading and their charts were reviewed. Four patients in the neuromuscular and four in the miscellaneous group presented with features consistent with HPP despite these patients having no specific diagnoses. Laboratories do not alert physicians in cases with low ALP levels. A persistently low level in patients with unspecified diagnoses could be a key to diagnose HPP. Implementing lab-specific ranges and alerting for low levels could prompt physicians to investigate for undiagnosed HPP.

  19. Low-level radioactive waste management: transitioning to off-site disposal at Los Alamos National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dorries, Alison M

    2010-11-09

    Facing the closure of nearly all on-site management and disposal capability for low-level radioactive waste (LLW), Los Alamos National Laboratory (LANL) is making ready to ship the majority of LLW off-site. In order to ship off-site, waste must meet the Treatment, Storage, and Disposal Facility's (TSDF) Waste Acceptance Criteria (WAC). In preparation, LANL's waste management organization must ensure LANL waste generators characterize and package waste compliantly and waste characterization documentation is complete and accurate. Key challenges that must be addressed to successfully make the shift to off-site disposal of LLW include improving the detail, accuracy, and quality of process knowledgemore » (PK) and acceptable knowledge (AK) documentation, training waste generators and waste management staff on the higher standard of data quality and expectations, improved WAC compliance for off-site facilities, and enhanced quality assurance throughout the process. Certification of LANL generators will allow direct off-site shipping of LLW from their facilities.« less

  20. Development of a low background liquid scintillation counter for a shallow underground laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erchinger, Jennifer L.; Aalseth, Craig E.; Bernacki, Bruce E.

    2015-08-20

    Pacific Northwest National Laboratory has recently opened a shallow underground laboratory intended for measurement of lowconcentration levels of radioactive isotopes in samples collected from the environment. The development of a low-background liquid scintillation counter is currently underway to further augment the measurement capabilities within this underground laboratory. Liquid scintillation counting is especially useful for measuring charged particle (e.g., B, a) emitting isotopes with no (orvery weak) gamma-ray yields. The combination of high-efficiency detection of charged particle emission in a liquid scintillation cocktail coupled with the low-background environment of an appropriately-designed shield located in a clean underground laboratory provides the opportunitymore » for increased-sensitivity measurements of a range of isotopes. To take advantage of the 35-meter water-equivalent overburden of the underground laboratory, a series of simulations have evaluated the instrumental shield design requirements to assess the possible background rate achievable. This report presents the design and background evaluation for a shallow underground, low background liquid scintillation counter design for sample measurements.« less

  1. Confirmatory radiological survey of the BORAX-V turbine building Idaho National Engineering Laboratory, Idaho Falls, Idaho

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stevens, G.H.; Coleman, R.L.; Jensen, M.K.

    1993-07-01

    An independent assessment of the remediation of the BORAX-V (Boiling Water Reactor Experiment) turbine building at the Idaho National Engineering Laboratory (INEL), Idaho Falls, Idaho, was accomplished by the Oak Ridge National Laboratory Pollutant Assessments Group (ORNL/PAG). The purpose of the assessment was to confirm the site`s compliance with applicable Department of Energy guidelines. The assessment included reviews of both the decontamination and decommissioning Plan and data provided from the pre- and post-remedial action surveys and an independent verification survey of the facility. The independent verification survey included determination of background exposure rates and soil concentrations, beta-gamma and gamma radiationmore » scans, smears for detection of removable contamination, and direct measurements for alpha and beta-gamma radiation activity on the basement and mezzanine floors and the building`s interior and exterior walls. Soil samples were taken, and beta-gamma and gamma radiation exposure rates were measured on areas adjacent to the building. Results of measurements on building surfaces at this facility were within established contamination guidelines except for elevated beta-gamma radiation levels located on three isolated areas of the basement floor. Following remediation of these areas, ORNL/PAG reviewed the remedial action contractor`s report and agreed that remediation was effective in removing the source of the elevated direct radiation. Results of all independent soil analyses for {sup 60}Co were below the detection limit. The highest {sup 137}Cs analysis result was 4.6 pCi/g; this value is below the INEL site-specific guideline of 10 pCi/g.« less

  2. Mineralogy of selected sedimentary interbeds at or near the Idaho National Engineering Laboratory, Idaho

    USGS Publications Warehouse

    Reed, Michael F.; Bartholomay, Roy C.

    1994-01-01

    The U.S. Geological Survey (USGS) Project Office at the Idaho National Engineering Laboratory (INEL), in cooperation with the U.S. Department of Energy and Idaho State University, analyzed 66 samples from sedimentary interbed cores during a 38-month period beginning in October 1990 to determine bulk and clay mineralogy. These cores had been collected from 19 sites in the Big Lost River Basin, 2 sites in the Birch Creek Basin, and 1 site in the Mud Lake Basin, and were archived at the USGS lithologic core library at the INEL. Mineralogy data indicate that the core samples from the Big Lost River Basin have larger mean and median percentages of quartz, total feldspar, and total clay minerals, but smaller mean and median percentages of calcite than the core samples from the Birch Creek Basin. Core samples from the Mud Lake Basin have abundant quartz, total feldspar, calcite, and total clay minerals.

  3. The results of an ecological risk assessment screening at the Idaho National Engineering`s waste area group 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    VanHorn, R.

    1995-11-01

    The Idaho National Engineering Laboratory (INEL) is a Department of Energy (DOE) facility located in southeastern Idaho and occupies approximately 890 square miles on the northwestern portion of the eastern Snake River Plain. INEL has been devoted to nuclear energy research and related activities since its establishment in 1949. In the process of fulfilling this mission, wastes were generated, including radioactive and hazardous materials. Most materials were effectively stored or disposed of, however, some release of contaminants to the environment has occurred. For this reason, the INEL was listed by the US environmental Protection Agency on the National Priorities Listmore » (NPL), in November, 1989. This report describes the results of an ecological risk assessment performed for the Waste Area Groups 2 (WAG 2) at the INEL. It also summarizes the performance of screening level ecological risk assessments (SLERA).« less

  4. Structural analysis of hatch cover plates on FMEF high bay mezzanine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dixson, G.E.

    1997-05-29

    In order to move the Idaho National Engineering Laboratory (INEL) Light Duty Utility Arm (LDUA) trailer into position for testing on the Fuels and Materials Examination Facility (FMEF) 42 ft level mezzanine one of the trailer`s wheels will have to sit on a circular hatch cover fabricated from one-inch thick steel plate. The attached calculations verify that the hatch cover plate is strong enough to support the weight of the INEL LDUA trailer`s wheel.

  5. (Low-level waste disposal facility siting and site characterization)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mezga, L.J.; Ketelle, R.H.; Pin, F.G.

    A US team consisting of representatives of Oak Ridge National Laboratory (ORNL), Savannah River Plant (SRP), Savannah river Laboratory (SRL), and the Department of Energy Office of Defense Waste and Byproducts Management participated in the fourth meeting held under the US/French Radioactive Waste Management Agreement between the US Department of Energy and the Commissariat a l'Energie Atomique. This meeting, held at Agence Nationale pour les Gestion des Dechets Radioactifs' (ANDRA's) Headquarters in Paris, was a detailed, technical topical workshop focusing on Low-Level Waste Disposal Facility Siting and Site Characterization.'' The meeting also included a visit to the Centre de lamore » Manche waste management facility operated by ANDRA to discuss and observe the French approach to low-level waste management. The final day of the meeting was spent at the offices of Societe Generale pour les Techniques Nouvelles (SGN) discussing potential areas of future cooperation and exchange. 20 figs.« less

  6. Man vs. Machine: A Junior-level Laboratory Exercise Comparing Human and Instrumental Detection Limits

    ERIC Educational Resources Information Center

    Elias, Ryan J.; Hopfer, Helene; Hofstaedter, Amanda N.; Hayes, John E.

    2017-01-01

    The human nose is a very sensitive detector and is able to detect potent aroma compounds down to low ng/L levels. These levels are often below detection limits of analytical instrumentation. The following laboratory exercise is designed to compare instrumental and human methods for the detection of volatile odor active compounds. Reference…

  7. Development of a Low-Level Ar-37 Calibration Standard

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, Richard M.; Aalseth, Craig E.; Bowyer, Ted W.

    Argon-37 is an important environmental signature of an underground nuclear explosion. Producing and quantifying low-level 37Ar standards is an important step in the development of sensitive field measurement instruments for use during an On-Site Inspection, a key provision of the Comprehensive Nuclear-Test-Ban Treaty. This paper describes progress at Pacific Northwest National Laboratory (PNNL) in the development of a process to generate and quantify low-level 37Ar standard material, which can then be used to calibrate sensitive field systems at activities consistent with soil background levels. The 37Ar used for our work was generated using a laboratory-scale, high-energy neutron source to irradiatemore » powdered samples of calcium carbonate. Small aliquots of 37Ar were then extracted from the head space of the irradiated samples. The specific activity of the head space samples, mixed with P10 (90% stable argon:10% methane by mole fraction) count gas, is then derived using the accepted Length-Compensated Internal-Source Proportional Counting method. Due to the low activity of the samples, a set of three Ultra-Low Background Proportional-Counters designed and fabricated at PNNL from radio-pure electroformed copper was used to make the measurements in PNNL’s shallow underground counting laboratory. Very low background levels (<10 counts/day) have been observed in the spectral region near the 37Ar emission feature at 2.8 keV. Two separate samples from the same irradiation were measured. The first sample was counted for 12 days beginning 28 days after irradiation, the second sample was counted for 24 days beginning 70 days after irradiation (the half-life of 37Ar is 35.0 days). Both sets of measurements were analyzed and yielded very similar results for the starting activity (~0.1 Bq) and activity concentration (0.15 mBq/ccSTP argon) after P10 count gas was added. A detailed uncertainty model was developed based on the ISO Guide to the Expression of Uncertainty

  8. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of low-level silver by graphite furnace atomic absorption spectrophotometry

    USGS Publications Warehouse

    Damrau, D.L.

    1993-01-01

    Increased awareness of the quality of water in the United States has led to the development of a method for determining low levels (0.2-5.0 microg/L) of silver in water samples. Use of graphite furnace atomic absorption spectrophotometry provides a sensitive, precise, and accurate method for determining low-level silver in samples of low ionic-strength water, precipitation water, and natural water. The minimum detection limit determined for low-level silver is 0.2 microg/L. Precision data were collected on natural-water samples and SRWS (Standard Reference Water Samples). The overall percent relative standard deviation for natural-water samples with silver concentrations more than 0.2 microg/L was less than 40 percent throughout the analytical range. For the SRWS with concentrations more than 0.2 microg/L, the overall percent relative standard deviation was less than 25 percent throughout the analytical range. The accuracy of the results was determined by spiking 6 natural-water samples with different known concentrations of the silver standard. The recoveries ranged from 61 to 119 percent at the 0.5-microg/L spike level. At the 1.25-microg/L spike level, the recoveries ranged from 92 to 106 percent. For the high spike level at 3.0 microg/L, the recoveries ranged from 65 to 113 percent. The measured concentrations of silver obtained from known samples were within the Branch of Quality Assurance accepted limits of 1 1/2 standard deviations on the basis of the SRWS program for Inter-Laboratory studies.

  9. INEL BNCT Research Program annual report, 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Venhuizen, J.R.

    1993-05-01

    This report is a summary of the progress and research produced for the Idaho National Engineering Laboratory Boron Neutron Capture Therapy (BNCT) Research Program for calendar year 1992. Contributions from all the principal investigators about their individual projects are included, specifically, chemistry (pituitary tumor targeting compounds, boron drug development including liposomes, lipoproteins, and carboranylalanine derivatives), pharmacology (murine screenings, toxicity testing, inductively coupled plasma-atomic emission spectroscopy (ICP-AES) analysis of biological samples), physics (radiation dosimetry software, neutron beam and filter design, neutron beam measurement dosimetry), and radiation biology (small and large animal models tissue studies and efficacy studies). Information on the potentialmore » toxicity of borocaptate sodium and boronophenylalanine is presented, results of 21 spontaneous-tumor-bearing dogs that have been treated with BNCT at the Brookhaven National Laboratory (BNL) Medical Research Reactor (BMRR) are discussed, and predictions for an epithermal-neutron beam at the Georgia Tech Research Reactor (GTRR) are shown. Cellular-level boron detection and localization by secondary ion mass spectrometry, sputter-initiated resonance ionization spectroscopy, low atomization resonance ionization spectroscopy, and alpha track are presented. Boron detection by ICP-AES is discussed in detail. Several boron carrying drugs exhibiting good tumor uptake are described. Significant progress in the potential of treating pituitary tumors with BNCT is presented. Measurement of the epithermal-neutron flux at BNL and comparison to predictions are shown. Calculations comparing the GTRR and BMRR epithermal-neutron beams are also presented. Individual progress reports described herein are separately abstracted and indexed for the database.« less

  10. University Research Consortium annual review meeting program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-07-01

    This brochure presents the program for the first annual review meeting of the University Research Consortium (URC) of the Idaho National Engineering Laboratory (INEL). INEL is a multiprogram laboratory with a distinctive role in applied engineering. It also conducts basic science research and development, and complex facility operations. The URC program consists of a portfolio of research projects funded by INEL and conducted at universities in the United States. In this program, summaries and participant lists for each project are presented as received from the principal investigators.

  11. Cultural Resource Protection Plan for the Remote-Handled Low-Level Waste Disposal Facility at the Idaho National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pace, Brenda Ringe; Gilbert, Hollie Kae

    2015-05-01

    This plan addresses cultural resource protection procedures to be implemented during construction of the Remote Handled Low Level Waste project at the Idaho National Laboratory. The plan proposes pre-construction review of proposed ground disturbing activities to confirm avoidance of cultural resources. Depending on the final project footprint, cultural resource protection strategies might also include additional survey, protective fencing, cultural resource mapping and relocation of surface artifacts, collection of surface artifacts for permanent curation, confirmation of undisturbed historic canal segments outside the area of potential effects for construction, and/or archaeological test excavations to assess potential subsurface cultural deposits at known culturalmore » resource locations. Additionally, all initial ground disturbing activities will be monitored for subsurface cultural resource finds, cultural resource sensitivity training will be conducted for all construction field personnel, and a stop work procedure will be implemented to guide assessment and protection of any unanticipated discoveries after initial monitoring of ground disturbance.« less

  12. Probable hydrologic effects of a hypothetical failure of Mackay Dam on the Big Lost River Valley from Mackay, Idaho to the Idaho National Engineering Laboratory

    USGS Publications Warehouse

    Druffel, Leroy; Stiltner, Gloria J.; Keefer, Thomas N.

    1979-01-01

    Mackay Dam is an irrigation reservoir on the Big Lost River, Idaho, approximately 7.2 kilometers northwest of Mackay, Idaho. Consequences of possible rupture of the dam have long concerned the residents of the river valley. The presence of reactors and of a management complex for nuclear wastes on the reservation of the Idaho National Engineering Laboratory (INEL), near the river , give additional cause for concern over the consequences of a rupture of Mackay Dam. The objective of this report is to calculate and route the flood wave resulting from the hypothetical failure of Mackay Dam downstream to the INEL. Both a full and a 50 percent partial breach of this dam are investigated. Two techniques are used to develop the dam-break model. The method of characteristics is used to propagate the shock wave after the dam fails. The linear implicit finite-difference solution is used to route the flood wave after the shock wave has dissipated. The time of travel of the flood wave, duration of flooding, and magnitude of the flood are determined for eight selected sites from Mackay Dam, Idaho, through the INEL diversion. At 4.2 kilometers above the INEL diversion, peak discharges of 1,550.2 and 1,275 cubic meters per second and peak flood elevations of 1,550.3 and 1,550.2 meters were calculated for the full and partial breach, respectively. Flood discharges and flood peaks were not compared for the area downstream of the diversion because of the lack of detailed flood plain geometry. (Kosco-USGS)

  13. Evaluation of field sampling and preservation methods for strontium-90 in ground water at the Idaho National Engineering Laboratory, Idaho

    USGS Publications Warehouse

    Cecil, L.D.; Knobel, L.L.; Wegner, S.J.; Moore, L.L.

    1989-01-01

    Water from four wells completed in the Snake River Plain aquifer was sampled as part of the U.S. Geological Survey 's quality assurance program to evaluate the effect of filtration and preservation methods on strontium-90 concentrations in groundwater at the Idaho National Engineering Laboratory. Water from each well was filtered through either a 0.45-micrometer membrane or a 0.1-micrometer membrane filter; unfiltered samples also were collected. Two sets of filtered and two sets of unfiltered samples was preserved in the field with reagent-grade hydrochloric acid and the other set of samples was not acidified. For water from wells with strontium-90 concentrations at or above the reporting level, 94% or more of the strontium-90 is in true solution or in colloidal particles smaller than 0.1 micrometer. These results suggest that within-laboratory reproducibility for strontium-90 in groundwater at the INEL is not significantly affected by changes in filtration and preservation methods used for sample collections. (USGS)

  14. Opportune Landing Site CBR and Low-Density Laboratory Database

    DTIC Science & Technology

    2008-05-01

    Program Opportune Landing Site CBR and Low- Density Laboratory Database Larry S. Danyluk, Sally A. Shoop, Rosa T. Affleck, and Wendy L. Wieder...Opportune Landing Site Program ERDC/CRREL TR-08-9 May 2008 Opportune Landing Site CBR and Low- Density Laboratory Database Larry S. Danyluk, Sally A...reproduce in-situ density , moisture, and CBR values and therefore do not accurately repre- sent the complete range of these values measured in the field

  15. Decontamination and decommissioning of the BORAX-V leach pond. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, D.L.

    1985-01-01

    This report describes the decontamination and decommissioning (D and D) of the BORAX-V leach pond located at the Idaho National Engineering Laboratory (INEL). The leach pond became radioactively contaminated from the periodic discharge of low-level liquid waste during operation of the Boiling Water Reactor Experiments (BORAX) from 1954 to 1964. This report describes work performed to accomplish the D and D objectives of stabilizing the leach pond and preventing the spread of contamination. D and D of the BORAX-V leach pond consisted to backfilling the pond with clean soil, grading and seeding the area, and erecting a permanent marker tomore » identify very low-level subsurface contamination.« less

  16. Safe disposal of radionuclides in low-level radioactive-waste repository sites; Low-level radioactive-waste disposal workshop, U.S. Geological Survey, July 11-16, 1987, Big Bear Lake, Calif., Proceedings

    USGS Publications Warehouse

    Bedinger, Marion S.; Stevens, Peter R.

    1990-01-01

    In the United States, low-level radioactive waste is disposed by shallow-land burial. Low-level radioactive waste generated by non-Federal facilities has been buried at six commercially operated sites; low-level radioactive waste generated by Federal facilities has been buried at eight major and several minor Federally operated sites (fig. 1). Generally, low-level radioactive waste is somewhat imprecisely defined as waste that does not fit the definition of high-level radioactive waste and does not exceed 100 nCi/g in the concentration of transuranic elements. Most low-level radioactive waste generated by non-Federal facilities is generated at nuclear powerplants; the remainder is generated primarily at research laboratories, hospitals, industrial facilities, and universities. On the basis of half lives and concentrations of radionuclides in low-level radioactive waste, the hazard associated with burial of such waste generally lasts for about 500 years. Studies made at several of the commercially and Federally operated low-level radioactive-waste repository sites indicate that some of these sites have not provided containment of waste nor the expected protection of the environment.

  17. Development of a regional groundwater flow model for the area of the Idaho National Engineering Laboratory, Eastern Snake River Plain Aquifer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCarthy, J.M.; Arnett, R.C.; Neupauer, R.M.

    This report documents a study conducted to develop a regional groundwater flow model for the Eastern Snake River Plain Aquifer in the area of the Idaho National Engineering Laboratory. The model was developed to support Waste Area Group 10, Operable Unit 10-04 groundwater flow and transport studies. The products of this study are this report and a set of computational tools designed to numerically model the regional groundwater flow in the Eastern Snake River Plain aquifer. The objective of developing the current model was to create a tool for defining the regional groundwater flow at the INEL. The model wasmore » developed to (a) support future transport modeling for WAG 10-04 by providing the regional groundwater flow information needed for the WAG 10-04 risk assessment, (b) define the regional groundwater flow setting for modeling groundwater contaminant transport at the scale of the individual WAGs, (c) provide a tool for improving the understanding of the groundwater flow system below the INEL, and (d) consolidate the existing regional groundwater modeling information into one usable model. The current model is appropriate for defining the regional flow setting for flow submodels as well as hypothesis testing to better understand the regional groundwater flow in the area of the INEL. The scale of the submodels must be chosen based on accuracy required for the study.« less

  18. Upper-Level Undergraduate Chemistry Students' Goals for Their Laboratory Coursework

    ERIC Educational Resources Information Center

    DeKorver, Brittland K.; Towns, Marcy H.

    2016-01-01

    Efforts to reform undergraduate chemistry laboratory coursework typically focus on the curricula of introductory-level courses, while upper-level courses are bypassed. This study used video-stimulated recall to interview 17 junior- and senior- level chemistry majors after they carried out an experiment as part of a laboratory course. It is assumed…

  19. Cultural change and support of waste minimization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boylan, M.S.

    1991-12-31

    The process of bringing a subject like pollution prevention to top of mind awareness, where designed to prevent waste becomes part of business as usual, is called cultural change. With Department of Energy orders and management waste minimization commitment statements on file, the REAL work is just beginning at the Idaho National Engineering Laboratory (INEL); shaping the attitudes of 11,000+ employees. The difficulties of such a task are daunting. The 890 square mile INEL site and in-town support offices mean a huge diversity of employee jobs and waste streams; from cafeteria and auto maintenance wastes to high-level nuclear waste casks.more » INEL is pursuing a three component cultural change strategy: training, publicity, and public outreach. To meet the intent of DOE orders, all INEL employees are slated to receive pollution prevention orientation training. More technical training is given to targeted groups like purchasing and design engineering. To keep newly learned pollution prevention concepts top-of-mind, extensive site-wide publicity is being developed and conducted, culminating in the April Pollution Prevention Awareness Week coinciding with Earth Day 1992. Finally, news of INEL pollution prevention successes is shared with the public to increase their overall environmental awareness and their knowledge of INEL activities. An important added benefit is the sense of pride the program instills in INEL employees to have their successes displayed so publicly.« less

  20. The Master level optics laboratory at the Institute of Optics

    NASA Astrophysics Data System (ADS)

    Adamson, Per

    2017-08-01

    The master level optics laboratory is a biannual, intensive laboratory course in the fields of geometrical, physical and modern optics. This course is intended for the master level student though Ph.D. advisors which often recommend it to their advisees. The students are required to complete five standard laboratory experiments and an independent project during a semester. The goals of the laboratory experiments are for the students to get hands-on experience setting up optical laboratory equipment, collecting and analyzing data, as well as to communicate key results. The experimental methods, analysis, and results of the standard experiments are submitted in a journal style report, while an oral presentation is given for the independent project.

  1. Rise of Buoyant Emissions from Low-Level Sources in the Presence of Upstream and Downstream Obstacles

    NASA Astrophysics Data System (ADS)

    Pournazeri, Sam; Princevac, Marko; Venkatram, Akula

    2012-08-01

    Field and laboratory studies have been conducted to investigate the effect of surrounding buildings on the plume rise from low-level buoyant sources, such as distributed power generators. The field experiments were conducted in Palm Springs, California, USA in November 2010 and plume rise from a 9.3 m stack was measured. In addition to the field study, a laboratory study was conducted in a water channel to investigate the effects of surrounding buildings on plume rise under relatively high wind-speed conditions. Different building geometries and source conditions were tested. The experiments revealed that plume rise from low-level buoyant sources is highly affected by the complex flows induced by buildings stationed upstream and downstream of the source. The laboratory results were compared with predictions from a newly developed numerical plume-rise model. Using the flow measurements associated with each building configuration, the numerical model accurately predicted plume rise from low-level buoyant sources that are influenced by buildings. This numerical plume rise model can be used as a part of a computational fluid dynamics model.

  2. LPT. Low power test (TAN640) interior. Basement level. Camera facing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. Low power test (TAN-640) interior. Basement level. Camera facing north. Cable trays and conduit cross tunnel between critical experiment cell and critical experiment control room. Construction 93% complete. Photographer: Jack L. Anderson. Date: October 23, 1957. INEEL negative no. 57-5339 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  3. Perceptions of Competence of Three Levels of Medical Laboratory Personnel.

    ERIC Educational Resources Information Center

    Davis, Judith A.

    Commonalities and differences in the perception of competence among three levels of medical laboratory personnel were assessed through a survey of 100 educators, chief technologists, and working technicians. Respondents rated medical technologists (MTs), medical laboratory technicians (MLTs), and certified laboratory assistants (CLAs) on 270 tasks…

  4. Evaluation of a predictive ground-water solute-transport model at the Idaho National Engineering Laboratory, Idaho

    USGS Publications Warehouse

    Lewis, Barney D.; Goldstein, Flora J.

    1982-01-01

    Aqueous chemical and radioactive wastes discharged to shallow ponds and to shallow or deep wells on the Idaho National Engineering Laboratory (INEL) since 1952 have affected the quality of the ground water in the underlying Snake River Plain aquifer. The aqueous wastes have created large and laterally dispersed concentration plumes within the aquifer. The waste plumes with the largest areal distribution are those of chloride , tritium, and with high specific conductance values. The data from eight wells drilled near the southern INEL boundary during the summer of 1980 were used to evaluate the accuracy of a predictive modeling study completed in 1973, and to simulate 1980 positions of chloride and tritium plumes. Data interpretation from the drilling program indicates that the hydrogeologic characteristics of the subsurface rocks have marked effects on the regional ground-water flow regimen and, therefore, the movement of aqueous wastes. As expected, the waste plumes projected by the computer model for 1980, extended somewhat further downgradient than indicated by well data due to conservative worst-case assumptions in the model input and inacurate approximations of subsequent waste discharge and aquifer recharge conditions. (USGS)

  5. Quality-assurance plan and field methods for quality-of-water activities, U.S. Geological Survey, Idaho National Engineering Laboratory, Idaho

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mann, L.J.

    1996-10-01

    Water-quality activities at the Idaho National Engineering Laboratory (INEL) Project Office are part of the US Geological Survey`s (USGS) Water Resources Division (WRD) mission of appraising the quantity and quality of the Nation`s water resources. The purpose of the Quality Assurance Plan (QAP) for water-quality activities performed by the INEL Project Office is to maintain and improve the quality of technical products, and to provide a formal standardization, documentation, and review of the activities that lead to these products. The principles of this plan are as follows: (1) water-quality programs will be planned in a competent manner and activities willmore » be monitored for compliance with stated objectives and approaches; (2) field, laboratory, and office activities will be performed in a conscientious and professional manner in accordance with specified WRD practices and procedures by qualified and experienced employees who are well trained and supervised, if or when, WRD practices and procedures are inadequate, data will be collected in a manner that its quality will be documented; (3) all water-quality activities will be reviewed for completeness, reliability, credibility, and conformance to specified standards and guidelines; (4) a record of actions will be kept to document the activity and the assigned responsibility; (5) remedial action will be taken to correct activities that are deficient.« less

  6. Evaluation of field sampling and preservation methods for strontium-90 in ground water at the Idaho National Engineering Laboratory, Idaho

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cecil, L.D.; Knobel, L.L.; Wegner, S.J.

    1989-01-01

    Water from four wells completed in the Snake River Plain aquifer was sampled as part of the US Geological Survey's quality assurance program to evaluate the effect of filtration and preservation methods on strontium-90 concentrations in groundwater at the Idaho National Engineering Laboratory. Water from each well was filtered through either a 0.45-micrometer membrane or a 0.1-micrometer membrane filter; unfiltered samples also were collected. Two sets of filtered and two sets of unfiltered samples was preserved in the field with reagent-grade hydrochloric acid and the other set of samples was not acidified. For water from wells with strontium-90 concentrations atmore » or above the reporting level, 94% or more of the strontium-90 is in true solution or in colloidal particles smaller than 0.1 micrometer. These results suggest that within-laboratory reproducibility for strontium-90 in groundwater at the INEL is not significantly affected by changes in filtration and preservation methods used for sample collections. 13 refs., 2 figs., 6 tabs.« less

  7. Low Energy Neutrino Physics at the Kuo-Sheng Reactor Laboratory in Taiwan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, S.-T.

    2006-11-17

    A laboratory has been constructed by the TEXONO Collaboration at the Kuo-Sheng Reactor Power Plant in Taiwan to study low energy neutrino physics. A limit on the neutrino magnetic moment of {mu}{nu}({nu}-bare) < 7.2 x 10-11 {mu}B at 90% confidence level has been achieved from measurements with a high-purity germanium detector, as well as the electron neutrinos ({nu}{sub e}) produced from nuclear power reactors has been studied. Other research program at Kuo-Sheng are surveyed.

  8. Low vibration laboratory with a single-stage vibration isolation for microscopy applications.

    PubMed

    Voigtländer, Bert; Coenen, Peter; Cherepanov, Vasily; Borgens, Peter; Duden, Thomas; Tautz, F Stefan

    2017-02-01

    The construction and the vibrational performance of a low vibration laboratory for microscopy applications comprising a 100 ton floating foundation supported by passive pneumatic isolators (air springs), which rest themselves on a 200 ton solid base plate, are discussed. The optimization of the air spring system leads to a vibration level on the floating floor below that induced by an acceleration of 10 ng for most frequencies. Additional acoustic and electromagnetic isolation is accomplished by a room-in-room concept.

  9. Operational Strategies for Low-Level Radioactive Waste Disposal Site in Egypt - 13513

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mohamed, Yasser T.

    The ultimate aims of treatment and conditioning is to prepare waste for disposal by ensuring that the waste will meet the waste acceptance criteria of a disposal facility. Hence the purpose of low-level waste disposal is to isolate the waste from both people and the environment. The radioactive particles in low-level waste emit the same types of radiation that everyone receives from nature. Most low-level waste fades away to natural background levels of radioactivity in months or years. Virtually all of it diminishes to natural levels in less than 300 years. In Egypt, The Hot Laboratories and Waste Management Centermore » has been established since 1983, as a waste management facility for LLW and ILW and the disposal site licensed for preoperational in 2005. The site accepts the low level waste generated on site and off site and unwanted radioactive sealed sources with half-life less than 30 years for disposal and all types of sources for interim storage prior to the final disposal. Operational requirements at the low-level (LLRW) disposal site are listed in the National Center for Nuclear Safety and Radiation Control NCNSRC guidelines. Additional procedures are listed in the Low-Level Radioactive Waste Disposal Facility Standards Manual. The following describes the current operations at the LLRW disposal site. (authors)« less

  10. La-oxides as tracers for PuO{sub 2} to simulate contaminated aerosol behavior

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meyer, L.C.; Newton, G.J.; Cronenberg, A.W.

    1994-04-01

    An analytical and experimental study was performed on the use of lanthanide oxides (La-oxides) as surrogates for plutonium oxides (PuO{sub 2}) during simulated buried waste retrieval. This study determined how well the La-oxides move compared to PuO{sub 2} in aerosolized soils during retrieval scenarios. As part of the analytical study, physical properties of La-oxides and PuO{sub 2}, such as molecular diameter, diffusivity, density, and molecular weight are compared. In addition, an experimental study was performed in which Idaho National Engineering Laboratory (INEL) soil, INEL soil with lanthanides, and INEL soil with plutonium were aerosolized and collected in filters. Comparison ofmore » particle size distribution parameters from this experimental study show similarity between INEL soil, INEL soil with lanthanides, and INEL soil with plutonium.« less

  11. Modeling of pilot's visual behavior for low-level flight

    NASA Astrophysics Data System (ADS)

    Schulte, Axel; Onken, Reiner

    1995-06-01

    Developers of synthetic vision systems for low-level flight simulators deal with the problem to decide which features to incorporate in order to achieve most realistic training conditions. This paper supports an approach to this problem on the basis of modeling the pilot's visual behavior. This approach is founded upon the basic requirement that the pilot's mechanisms of visual perception should be identical in simulated and real low-level flight. Flight simulator experiments with pilots were conducted for knowledge acquisition. During the experiments video material of a real low-level flight mission containing different situations was displayed to the pilot who was acting under a realistic mission assignment in a laboratory environment. Pilot's eye movements could be measured during the replay. The visual mechanisms were divided into rule based strategies for visual navigation, based on the preflight planning process, as opposed to skill based processes. The paper results in a model of the pilot's planning strategy of a visual fixing routine as part of the navigation task. The model is a knowledge based system based upon the fuzzy evaluation of terrain features in order to determine the landmarks used by pilots. It can be shown that a computer implementation of the model selects those features, which were preferred by trained pilots, too.

  12. Survey of laboratory-acquired infections around the world in biosafety level 3 and 4 laboratories.

    PubMed

    Wurtz, N; Papa, A; Hukic, M; Di Caro, A; Leparc-Goffart, I; Leroy, E; Landini, M P; Sekeyova, Z; Dumler, J S; Bădescu, D; Busquets, N; Calistri, A; Parolin, C; Palù, G; Christova, I; Maurin, M; La Scola, B; Raoult, D

    2016-08-01

    Laboratory-acquired infections due to a variety of bacteria, viruses, parasites, and fungi have been described over the last century, and laboratory workers are at risk of exposure to these infectious agents. However, reporting laboratory-associated infections has been largely voluntary, and there is no way to determine the real number of people involved or to know the precise risks for workers. In this study, an international survey based on volunteering was conducted in biosafety level 3 and 4 laboratories to determine the number of laboratory-acquired infections and the possible underlying causes of these contaminations. The analysis of the survey reveals that laboratory-acquired infections have been infrequent and even rare in recent years, and human errors represent a very high percentage of the cases. Today, most risks from biological hazards can be reduced through the use of appropriate procedures and techniques, containment devices and facilities, and the training of personnel.

  13. Environmental management requirements/defensible costs project. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-02-01

    Lockheed Idaho Technologies Company (LITCO) used a systems engineering approach to develop the first formal requirements baseline for Idaho National Engineering Laboratory (INEL) Environmental Management (EM) Programs. The recently signed Settlement Agreement with the State of Idaho (Batt Agreement), along with dramatically reduced EM funding targets from Department of Energy (DOE) headquarters, drove the immediacy of this effort. Programs have linked top-level requirements to work scope to cost estimates. All EM work, grouped by decision units, was scrubbed by INEL EM programs and by an independent {open_quotes}Murder Board.{close_quotes} Direct participation of upper level management from LITCO and the DOE-Idaho Operationsmore » Office ensured best information and decisions. The result is a scrubbed down, defensible budget tied to top-level requirements for use in the upcoming DOE-Headquarters` budget workout, the Internal Review Board, the FY98 Activity Data Sheets submittal, and preparation of the FY97 control accounts and out-year plans. In addition to the remarkable accomplishments during the past eight weeks, major issues were identified and documented and follow-on tasks are underway which will lead to further improvements in INEL EM program management.« less

  14. Laboratory demonstration of a broadband six-level phase mask coronagraph.

    PubMed

    Patru, Fabien; Baudoz, Pierre; Galicher, Raphaël; Cao, Qing; Wang, Kai; Xing, Lujing; Boussaha, Faouzi; Firminy, Josiane; Bonafous, Marion

    2018-04-16

    The six-level phase mask (SLPM) can be used in a focal plane as an efficient coronagraph [Opt. Express 22, 1884 (2014)]. It has several advantages: high-contrast imaging in broadband with small inner working angle; easy fabrication at low cost by photolithography and reactive ion etching processes; easy implementation with no need of pupil apodization. We present in this paper the first laboratory results demonstrating the high performance of a SLPM with an unobscured pupil. The on-axis attenuation reaches 2 × 10 -5 at λ = 800 nm and is better than 10 -4 over a 10% spectral bandwidth and better than 10 -3 over a 20% bandwidth. Finally, the detection of a planet can be achieved down to 1 λ/D.

  15. The Tanzania experience: clinical laboratory testing harmonization and equipment standardization at different levels of a tiered health laboratory system.

    PubMed

    Massambu, Charles; Mwangi, Christina

    2009-06-01

    The rapid scale-up of the care and treatment programs in Tanzania during the preceding 4 years has greatly increased the demand for quality laboratory services for diagnosis of HIV and monitoring patients during antiretroviral therapy. Laboratory services were not in a position to cope with this demand owing to poor infrastructure, lack of human resources, erratic and/or lack of reagent supply and commodities, and slow manual technologies. With the limited human resources in the laboratory and the need for scaling up the care and treatment program, it became necessary to install automated equipment and train personnel for the increased volume of testing and new tests across all laboratory levels. With the numerous partners procuring equipment, the possibility of a multitude of equipment platforms with attendant challenges for procurement of reagents, maintenance of equipment, and quality assurance arose. Tanzania, therefore, had to harmonize laboratory tests and standardize laboratory equipment at different levels of the laboratory network. The process of harmonization of tests and standardization of equipment included assessment of laboratories, review of guidelines, development of a national laboratory operational plan, and stakeholder advocacy. This document outlines this process.

  16. Low magnesium level

    MedlinePlus

    ... in the body that convert or use energy ( metabolism ). When the level of magnesium in the body drops below normal, symptoms of low magnesium may develop. Common causes of low magnesium include: Alcohol use Burns that affect a large area of ...

  17. An Ultra Low Cost Wireless Communications Laboratory for Education and Research

    ERIC Educational Resources Information Center

    Linn, Y.

    2012-01-01

    This paper presents an ultra-low-cost wireless communications laboratory that is based on a commercial off-the-shelf field programmable gate array (FPGA) development board that is both inexpensive and available worldwide. The total cost of the laboratory is under USD $200, but it includes complete transmission, channel emulation, reception…

  18. Hydrologic conditions at the Idaho National Engineering Laboratory, Idaho, emphasis; 1974-1978

    USGS Publications Warehouse

    Barraclough, Jack T.; Lewis, Barney D.; Jensen, Rodger G.

    1981-01-01

    Aqueous chemical and radioactive wastes have been discharged to shallow ponds and to shallow or deep wells on the Idaho National Engineering Laboratory (INEL) since 1952 and has affected the quality of the ground water in the underlying Snake River Plain aquifer. Ongoing studies conducted from 1974 through 1978 have shown the perpetuation of a perched ground-water zone in the basalt underlying the waste disposal ponds at the INEL 's Test Reactor Area and of several waste plumes in the regional aquifer created by deep well disposal at the Idaho Chemical Processing Plant (ICPP). The perched zone contains tritium, chromium-51, cobalt-60, strontium-90, and several nonradioactive chemicals. Tritium has formed the largest waste plume south of the ICPP, and accounts for 95 percent of the total radioacticity disposed of through the ICPP disposal well. Waste plumes with similar configurations and flowpaths contain sodium, chloride, and nitrate. Strontium-90, iodine-129, and cesium-137 are also discharged through the well but they are sorbed from solution as they move through the aquifer or are discharged in very small quantities. Strontium-90 and iodine-129 have formed small waste plumes and cesium-137 is not detectable in ground-water samples. Radionuclide plume size and concentrations therein are controlled by aquifer flow conditions, the quantity discharged, radioactive decay, sorption, dilution by dispersion, and perhaps other chemical reactions. Chemical wastes are subject to the same processes except for radioactive decay. (USGS)

  19. Statistical analysis of the calibration procedure for personnel radiation measurement instruments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bush, W.J.; Bengston, S.J.; Kalbeitzer, F.L.

    1980-11-01

    Thermoluminescent analyzer (TLA) calibration procedures were used to estimate personnel radiation exposure levels at the Idaho National Engineering Laboratory (INEL). A statistical analysis is presented herein based on data collected over a six month period in 1979 on four TLA's located in the Department of Energy (DOE) Radiological and Environmental Sciences Laboratory at the INEL. The data were collected according to the day-to-day procedure in effect at that time. Both gamma and beta radiation models are developed. Observed TLA readings of thermoluminescent dosimeters are correlated with known radiation levels. This correlation is then used to predict unknown radiation doses frommore » future analyzer readings of personnel thermoluminescent dosimeters. The statistical techniques applied in this analysis include weighted linear regression, estimation of systematic and random error variances, prediction interval estimation using Scheffe's theory of calibration, the estimation of the ratio of the means of two normal bivariate distributed random variables and their corresponding confidence limits according to Kendall and Stuart, tests of normality, experimental design, a comparison between instruments, and quality control.« less

  20. Topic I: Induced changes in hydrology at low-level radioactive waste repository sites: A section in Safe disposal of radionuclides in low-level radioactive-waste repository sites; Low-level radioactive-waste disposal workshop, U.S. Geological Survey, July 11-16, 1987, Big Bear Lake, Calif., Proceedings (Circular 1036)

    USGS Publications Warehouse

    Prudic, David E.; Dennehy, Kevin F.; Bedinger, Marion S.; Stevens, Peter R.

    1990-01-01

    Engineering practices, including the excavation of trenches, placement of waste, nature of waste forms, backfilling procedures and materials, and trench-cover construction and materials at low-level radioactive-waste repository sites greatly affect the geohydrology of the sites. Engineering practices are dominant factors in eventual stability and isolation of the waste. The papers presented relating to Topic I were discussions of the hydrogeologic setting at existing low-level radioactive-waste repository sites and changes in the hydrology induced by site operations. Papers summarizing detailed studies presented at this workshop include those at sites near Sheffield, Ill.; Oak Ridge National Laboratory, Tenn.; West Valley, N.Y.; Maxey Flats, Ky.; Barnwell, S.C.; and Beatty, Nev. 

  1. FACTORS AFFECTING THE USE OF CAF2:MN THERMOLUMINESCENT DOSIMETERS FOR LOW-LEVEL ENVIRONMENTAL RADIATION MONITORING

    EPA Science Inventory

    An investigation was made of factors affecting the use of commercially-produced CaF2:Mn thermoluminescent dosimeters for low level environmental radiation monitoring. Calibration factors and self-dosing rates were quantified for 150 thermoluminescent dosimeters. Laboratory studie...

  2. The Laser Level as an Optics Laboratory Tool

    ERIC Educational Resources Information Center

    Kutzner, Mickey

    2013-01-01

    For decades now, the laser has been used as a handy device for performing ray traces in geometrical optics demonstrations and laboratories. For many ray- trace applications, I have found the laser level 3 to be even more visually compelling and easy for student use than the laser pointer.

  3. Improving pathology and laboratory medicine in low-income and middle-income countries: roadmap to solutions.

    PubMed

    Sayed, Shahin; Cherniak, William; Lawler, Mark; Tan, Soo Yong; El Sadr, Wafaa; Wolf, Nicholas; Silkensen, Shannon; Brand, Nathan; Looi, Lai Meng; Pai, Sanjay A; Wilson, Michael L; Milner, Danny; Flanigan, John; Fleming, Kenneth A

    2018-05-12

    Insufficient awareness of the centrality of pathology and laboratory medicine (PALM) to a functioning health-care system at policy and governmental level, with the resultant inadequate investment, has meant that efforts to enhance PALM in low-income and middle-income countries have been local, fragmented, and mostly unsustainable. Responding to the four major barriers in PALM service delivery that were identified in the first paper of this Series (workforce, infrastructure, education and training, and quality assurance), this second paper identifies potential solutions that can be applied in low-income and middle-income countries (LMICs). Increasing and retaining a quality PALM workforce requires access to mentorship and continuing professional development, task sharing, and the development of short-term visitor programmes. Opportunities to enhance the training of pathologists and allied PALM personnel by increasing and improving education provision must be explored and implemented. PALM infrastructure must be strengthened by addressing supply chain barriers, and ensuring laboratory information systems are in place. New technologies, including telepathology and point-of-care testing, can have a substantial role in PALM service delivery, if used appropriately. We emphasise the crucial importance of maintaining PALM quality and posit that all laboratories in LMICs should participate in quality assurance and accreditation programmes. A potential role for public-private partnerships in filling PALM services gaps should also be investigated. Finally, to deliver these solutions and ensure equitable access to essential services in LMICs, we propose a PALM package focused on these countries, integrated within a nationally tiered laboratory system, as part of an overarching national laboratory strategic plan. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. A Feasibility Study for the Laboratory Reduction of Low Level Radioactive Wastes

    DTIC Science & Technology

    1988-04-01

    the Los Alamos National Laboratory), pass the off-gases through a quench column, venturi scrubber , packed column. cordenser, de-mi ste-, re-heater...treatment of the off-gas. In addition to HEPA filters, all of the fully developed systems used sore type of scrubber in the exhaust system to remove...considerations shown in the table and the desired use of a muffle furnace with just a HEPA filter for the off-gas (no scrubbers ), only the slow burn ashing

  5. New reporting procedures based on long-term method detection levels and some considerations for interpretations of water-quality data provided by the U.S. Geological Survey National Water Quality Laboratory

    USGS Publications Warehouse

    Childress, Carolyn J. Oblinger; Foreman, William T.; Connor, Brooke F.; Maloney, Thomas J.

    1999-01-01

    This report describes the U.S. Geological Survey National Water Quality Laboratory?s approach for determining long-term method detection levels and establishing reporting levels, details relevant new reporting conventions, and provides preliminary guidance on interpreting data reported with the new conventions. At the long-term method detection level concentration, the risk of a false positive detection (analyte reported present at the long-term method detection level when not in sample) is no more than 1 percent. However, at the long-term method detection level, the risk of a false negative occurrence (analyte reported not present when present at the long-term method detection level concentration) is up to 50 percent. Because this false negative rate is too high for use as a default 'less than' reporting level, a more reliable laboratory reporting level is set at twice the determined long-term method detection level. For all methods, concentrations measured between the laboratory reporting level and the long-term method detection level will be reported as estimated concentrations. Non-detections will be censored to the laboratory reporting level. Adoption of the new reporting conventions requires a full understanding of how low-concentration data can be used and interpreted and places responsibility for using and presenting final data with the user rather than with the laboratory. Users must consider that (1) new laboratory reporting levels may differ from previously established minimum reporting levels, (2) long-term method detection levels and laboratory reporting levels may change over time, and (3) estimated concentrations are less certain than concentrations reported above the laboratory reporting level. The availability of uncensored but qualified low-concentration data for interpretation and statistical analysis is a substantial benefit to the user. A decision to censor data after they are reported from the laboratory may still be made by the user, if

  6. Development of an Ultra-Low Background Liquid Scintillation Counter for Trace Level Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erchinger, Jennifer L.; Orrell, John L.; Aalseth, Craig E.

    2015-09-01

    Low-level liquid scintillation counting (LSC) has been established as one of the radiation detection techniques useful in elucidating environmental processes and environmental monitoring around nuclear facilities. The Ultra-Low Background Liquid Scintillation Counter (ULB-LSC) under construction in the Shallow Underground Laboratory at Pacific Northwest National Laboratory aims to further reduce the MDAs and/or required sample processing. Through layers of passive shielding in conjunction with an active veto and 30 meters water equivalent overburden, the background reduction is expected to be 10 to 100 times below typical analytic low-background liquid scintillation systems. Simulations have shown an expected background of around 14 countsmore » per day. A novel approach to the light collection will use a coated hollow light guide cut into the inner copper shielding. Demonstration LSC measurements will show low-energy detection, spectral deconvolution, and alpha/beta discrimination capabilities, from trials with standards of tritium, strontium-90, and actinium-227, respectively. An overview of the system design and expected demonstration measurements will emphasize the potential applications of the ULB-LSC in environmental monitoring for treaty verification, reach-back sample analysis, and facility inspections.« less

  7. Accelerator-based techniques for the support of senior-level undergraduate physics laboratories

    NASA Astrophysics Data System (ADS)

    Williams, J. R.; Clark, J. C.; Isaacs-Smith, T.

    2001-07-01

    Approximately three years ago, Auburn University replaced its aging Dynamitron accelerator with a new 2MV tandem machine (Pelletron) manufactured by the National Electrostatics Corporation (NEC). This new machine is maintained and operated for the University by Physics Department personnel, and the accelerator supports a wide variety of materials modification/analysis studies. Computer software is available that allows the NEC Pelletron to be operated from a remote location, and an Internet link has been established between the Accelerator Laboratory and the Upper-Level Undergraduate Teaching Laboratory in the Physics Department. Additional software supplied by Canberra Industries has also been used to create a second Internet link that allows live-time data acquisition in the Teaching Laboratory. Our senior-level undergraduates and first-year graduate students perform a number of experiments related to radiation detection and measurement as well as several standard accelerator-based experiments that have been added recently. These laboratory exercises will be described, and the procedures used to establish the Internet links between our Teaching Laboratory and the Accelerator Laboratory will be discussed.

  8. Controlling changes - lessons learned from waste management facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, B.M.; Koplow, A.S.; Stoll, F.E.

    This paper discusses lessons learned about change control at the Waste Reduction Operations Complex (WROC) and Waste Experimental Reduction Facility (WERF) of the Idaho National Engineering Laboratory (INEL). WROC and WERF have developed and implemented change control and an as-built drawing process and have identified structures, systems, and components (SSCS) for configuration management. The operations have also formed an Independent Review Committee to minimize costs and resources associated with changing documents. WROC and WERF perform waste management activities at the INEL. WROC activities include storage, treatment, and disposal of hazardous and mixed waste. WERF provides volume reduction of solid low-levelmore » waste through compaction, incineration, and sizing operations. WROC and WERF`s efforts aim to improve change control processes that have worked inefficiently in the past.« less

  9. Transitional millisecond pulsars in the low-level accretion state

    NASA Astrophysics Data System (ADS)

    Jaodard, Amruta D.; Hessels, Jason W. T.; Archibald, Anne; Bogdanov, Slavko; Deller, Adam; Hernandez Santisteban, Juan; Patruno, Alessandro; D'Angelo, Caroline; Bassa, Cees; Amruta Jaodand

    2018-01-01

    In the canonical pulsar recycling scenario, a slowly spinning neutron star can be rejuvenated to rapid spin rates by the transfer of angular momentum and mass from a binary companion star. Over the last decade, the discovery of three transitional millisecond pulsars (tMSPs) has allowed us to study recycling in detail. These systems transition between accretion-powered (X-ray) and rotation-powered (radio) pulsar states within just a few days, raising questions such as: what triggers the state transition, when does the recycling process truly end, and what will the radio pulsar’s final spin rate be? Systematic multi-wavelength campaigns over the last decade have provided critical insights: multi-year-long, low-level accretion states showing coherent X-ray pulsations; extremely stable, bi-modal X-ray light curves; outflows probed by radio continuum emission; a surprising gamma-ray brightening during accretion, etc. In my thesis I am trying to bring these clues together to understand the low-level accretion process that recycles a pulsar. For example, recently we timed PSR J1023+0038 in the accretion state and found it to be spinning down ~26% faster compared to the non-accreting radio pulsar state. We are currently conducting simultaneous multi-wavelength campaigns (XMM, HST, Kepler and VLA) to understand the global variability of the accretion flow, as well as high-energy Fermi-LAT observations to probe the gamma-ray emission mechanism. I will highlight these recent developments, while also presenting a broad overview of tMSPs as exciting new laboratories to test low-level accretion onto magnetized neutron stars.

  10. Multiweek Cell Culture Project for Use in Upper-Level Biology Laboratories

    ERIC Educational Resources Information Center

    Marion, Rebecca E.; Gardner, Grant E.; Parks, Lisa D.

    2012-01-01

    This article describes a laboratory protocol for a multiweek project piloted in a new upper-level biology laboratory (BIO 426) using cell culture techniques. Human embryonic kidney-293 cells were used, and several culture media and supplements were identified for students to design their own experiments. Treatments included amino acids, EGF,…

  11. Initial testing of two DEMI (Driesbach Electromotive Inc. ) Model 4E zinc-air rechargeable cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hardin, J.E.; Martin, M.E.

    1989-10-23

    The purpose of this document is to report the results of INEL laboratory testing of two DEMI 4E Aerobic Power Battery Cells (collectively designated Pack 46 in INEL records). The 4E Aerobic Power Battery is a secondary battery developed privately by Driesbach Electromotive Inc. (DEMI). The battery employs zinc as the anode and a bifunctional air cathode. This testing was performed as the first phase of a cooperative agreement between INEL and DEMI leading to the construction and testing of electric vehicle-size cells, to be followed eventually by a battery pack. 3 refs., 3 figs., 5 tabs.

  12. Ultra-Low Level Plutonium Isotopes in the NIST SRM 4355A (Peruvian Soil-1)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Inn, Kenneth G.; LaRosa, Jerome; Nour, Svetlana

    2009-05-31

    For more than 20 years, countries and their agencies which monitor discharge sites and storage facilities have relied on the National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 4355 Peruvian Soil reference material. Its low fallout contamination makes it an ideal soil blank for measurements associated with terrestrial pathway to man studies. Presently, SRM 4355 is out of stock, and a new batch of the Peruvian soil is currently under development as future NIST SRM 4355A. Both environmental radioanalytical laboratories and mass spectrometry communities will benefit from this SRM. The former must assess their laboratory contamination andmore » measurement detection limits by measurement of blank sample material. The Peruvian Soil is so low in anthropogenic radionuclides that it is a suitable virtual blank. On the other hand, mass spectrometric laboratories have high sensitivity instruments that are capable of quantitative isotopic measurements at low plutonium levels of the SRM 4355 (first Peruvian Soil SRM) that provided the mass spectrometric community with the calibration, quality control, and testing material needed for methods development, and legal defensibility. The quantification of the ultra-low plutonium content in the SRM 4355A was a considerable challenge for the mass spectrometric laboratories. Careful blank control and correction, isobaric interferences, instrument stability, peak assessment, and detection assessment were necessary. Furthermore, a systematic statistical evaluation of the measurement results and considerable discussions with the mass spectroscopy metrologists were needed to derive the certified values and uncertainties. SRM 4355A will provide the mass spectrometric community with the quality control and testing material needed for higher sensitivity methods development, and legal defensibility.« less

  13. Ultra-low level plutonium isotopes in the NIST SRM 4355A (Peruvian Soil-1).

    PubMed

    Inn, Kenneth G W; LaRosa, Jerome; Nour, Svetlana; Brooks, George; LaMont, Steve; Steiner, Rob; Williams, Ross; Patton, Brad; Bostick, Debbie; Eiden, Gregory; Petersen, Steve; Douglas, Matthew; Beals, Donna; Cadieux, James; Hall, Greg; Goldberg, Steve; Vogt, Stephan

    2009-05-01

    For more than 20 years, countries and their agencies which monitor radionuclide discharge sites and storage facilities have relied on the National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 4355 Peruvian Soil. Its low fallout contamination makes it an ideal soil blank for measurements associated with terrestrial-pathway-to-man studies. Presently, SRM 4355 is out of stock, and a new batch of the Peruvian soil is currently under development as future NIST SRM 4355A. Both environmental radioanalytical laboratories and mass spectrometry communities will benefit from the use of this SRM. The former must assess their laboratory procedural contamination and measurement detection limits by measurement of blank sample material. The Peruvian Soil is so low in anthropogenic radionuclide content that it is a suitable virtual blank. On the other hand, mass spectrometric laboratories have high sensitivity instruments that are capable of quantitative isotopic measurements at low plutonium levels in the SRM 4355 (first Peruvian Soil SRM) that provided the mass spectrometric community with the calibration, quality control, and testing material needed for methods development and legal defensibility. The quantification of the ultra-low plutonium content in the SRM 4355A was a considerable challenge for the mass spectrometric laboratories. Careful blank control and correction, isobaric interferences, instrument stability, peak assessment, and detection assessment were necessary. Furthermore, a systematic statistical evaluation of the measurement results and considerable discussions with the mass spectroscopy metrologists were needed to derive the certified values and uncertainties. The one sided upper limit of the 95% tolerance with 95% confidence for the massic (239)Pu content in SRM 4355A is estimated to be 54,000 atoms/g.

  14. Low potassium level

    MedlinePlus

    ... of low potassium level include: Medicines, such as diuretics (water pills), certain antibiotics Diarrhea or vomiting Using ... potassium through a vein (IV). If you need diuretics, your provider may: Switch you to a form ...

  15. Organic solutes in ground water at the Idaho National Engineering Laboratory

    USGS Publications Warehouse

    Leenheer, Jerry A.; Bagby, Jefferson C.

    1982-01-01

    In August 1980, the U.S. Geological Survey started a reconnaissance survey of organic solutes in drinking water sources, ground-water monitoring wells, perched water table monitoring wells, and in select waste streams at the Idaho National Engineering Laboratory (INEL). The survey was to be a two-phase program. In the first phase, 77 wells and 4 potential point sources were sampled for dissolved organic carbon (DOC). Four wells and several potential point sources of insecticides and herbicides were sampled for insecticides and herbicides. Fourteen wells and four potential organic sources were sampled for volatile and semivolatile organic compounds. The results of the DOC analyses indicate no high level (>20 mg/L DOC) organic contamination of ground water. The only detectable insecticide or herbicide was a DDT concentration of 10 parts per trillion (0.01 microgram per liter) in one observation well. The volatile and semivolatile analyses do not indicate the presence of hazardous organic contaminants in significant amounts (>10 micrograms per liter) in the samples taken. Due to the lack of any significant organic ground-water contamination in this reconnaissance survey, the second phase of the study, which was to follow up the first phase by additional sampling of any contaminated wells, was canceled.

  16. Internal quality control indicators of cervical cytopathology exams performed in laboratories monitored by the External Quality Control Laboratory.

    PubMed

    Ázara, Cinara Zago Silveira; Manrique, Edna Joana Cláudio; Tavares, Suelene Brito do Nascimento; de Souza, Nadja Lindany Alves; Amaral, Rita Goreti

    2014-09-01

    To evaluate the impact of continued education provided by an external quality control laboratory on the indicators of internal quality control of cytopathology exams. The internal quality assurance indicators for cytopathology exams from 12 laboratories monitored by the External Quality Control Laboratory were evaluated. Overall, 185,194 exams were included, 98,133 of which referred to the period preceding implementation of a continued education program, while 87,061 referred to the period following this intervention. Data were obtained from the Cervical Cancer Database of the Brazilian National Health Service. Following implementation of the continued education program, the positivity index (PI) remained within recommended limits in four laboratories. In another four laboratories, the PI progressed from below the limits to within the recommended standards. In one laboratory, the PI remained low, in two laboratories, it remained very low, and in one, it increased from very low to low. The percentage of exams compatible with a high-grade squamous intraepithelial lesion (HSIL) remained within the recommended limits in five laboratories, while in three laboratories it progressed from below the recommended levels to >0.4% of the total number of satisfactory exams, and in four laboratories it remained below the standard limit. Both the percentage of atypical squamous cells of undetermined significance (ASC-US) in relation to abnormal exams, and the ratio between ASC-US and intraepithelial lesions remained within recommended levels in all the laboratories investigated. An improvement was found in the indicators represented by the positivity index and the percentage of exams compatible with a high-grade squamous intraepithelial lesion, showing that the role played by the external quality control laboratory in providing continued education contributed towards improving laboratory staff skills in detecting cervical cancer precursor lesions.

  17. Hydrologic conditions at the Idaho National Engineering Laboratory, 1982 to 1985

    USGS Publications Warehouse

    Pittman, J.R.; Fischer, P.R.; Jensen, R.G.

    1988-01-01

    Aqueous chemical and radioactive wastes discharged since 1952 to unlined ponds and wells at the INEL (Idaho National Engineering Laboratory) have affected water quality in perched groundwater zones and in the Snake River Plain Aquifer. Routine waste water disposal was changed from deep injection wells to ponds at the ICPP (Idaho Chemical Processing Plant) in 1984. During 1982-85, tritium concentrations increased in perched groundwater zones under disposal ponds, but cobalt-60 concentrations decreased. In 1985, perched groundwater under TRA disposal ponds contained up to 1,770 +or-30 pCi/mL (picocuries/milliliter) of tritium and 0.36+or-0.05 pCi/mL of cobalt-60. During 1982-85, tritium concentrations in water in the Snake River Plain aquifer decreased as much as 80 pCi/mL near the ICPP. In 1985, measurable tritium concentrations ranged from 0.9+or-0.3 to 93.4 +or-2.0 pCi/mL. Tritium was detected in groundwater near the southern boundary of the INEL, 9 miles south of the ICPP and TRA. Strontium-90 concentrations in groundwater, up to 63 +or-5 pCi/L (picocuries per liter) near the ICPP, generally were smaller than 1981 concentrations. Cesium-137 concentrations in groundwater near the ICPP ranged from 125 +or-14 to 237 +or-45 pCi/L. Maximum concentrations of plutonium-238 and plutonium-239 , -240 (undivided) were 1.31 +or-.0019 pCi/ml and 1.9 +or-0.00003 pCi/L. Sodium and chloride generally decreased during 1982-85. Nitrate concentrations increased near the TRA and NRF (Naval Reactors Facility) and decreased near the ICPP. (USGS)

  18. Some case studies of skewed (and other ab-normal) data distributions arising in low-level environmental research.

    PubMed

    Currie, L A

    2001-07-01

    Three general classes of skewed data distributions have been encountered in research on background radiation, chemical and radiochemical blanks, and low levels of 85Kr and 14C in the atmosphere and the cryosphere. The first class of skewed data can be considered to be theoretically, or fundamentally skewed. It is typified by the exponential distribution of inter-arrival times for nuclear counting events for a Poisson process. As part of a study of the nature of low-level (anti-coincidence) Geiger-Muller counter background radiation, tests were performed on the Poisson distribution of counts, the uniform distribution of arrival times, and the exponential distribution of inter-arrival times. The real laboratory system, of course, failed the (inter-arrival time) test--for very interesting reasons, linked to the physics of the measurement process. The second, computationally skewed, class relates to skewness induced by non-linear transformations. It is illustrated by non-linear concentration estimates from inverse calibration, and bivariate blank corrections for low-level 14C-12C aerosol data that led to highly asymmetric uncertainty intervals for the biomass carbon contribution to urban "soot". The third, environmentally, skewed, data class relates to a universal problem for the detection of excursions above blank or baseline levels: namely, the widespread occurrence of ab-normal distributions of environmental and laboratory blanks. This is illustrated by the search for fundamental factors that lurk behind skewed frequency distributions of sulfur laboratory blanks and 85Kr environmental baselines, and the application of robust statistical procedures for reliable detection decisions in the face of skewed isotopic carbon procedural blanks with few degrees of freedom.

  19. Requirements for diagnosis of malaria at different levels of the laboratory network in Africa.

    PubMed

    Long, Earl G

    2009-06-01

    The rapid increase of resistance to cheap, reliable antimalarials, the increasing cost of effective drugs, and the low specificity of clinical diagnosis has increased the need for more reliable diagnostic methods for malaria. The most commonly used and most reliable remains microscopic examination of stained blood smears, but this technique requires skilled personnel, precision instruments, and ideally a source of electricity. Microscopy has the advantage of enabling the examiner to identify the species, stage, and density of an infection. An alternative to microscopy is the rapid diagnostic test (RDT), which uses a labeled monoclonal antibody to detect circulating parasitic antigens. This test is most commonly used to detect Plasmodium falciparum infections and is available in a plastic cassette format. Both microscopy and RDTs should be available at all levels of laboratory service in endemic areas, but in peripheral laboratories with minimally trained staff, the RDT may be a more practical diagnostic method.

  20. A Simple Low-Cost Lock-In Amplifier for the Laboratory

    ERIC Educational Resources Information Center

    Sengupta, Sandip K.; Farnham, Jessica M.; Whitten, James E.

    2005-01-01

    The creation of a simple, low-cost lock-in amplifier (LIA) suitable for use in the chemistry teaching laboratory is described. The use of integrated circuits and few components are necessary to adequately accomplish lock-in amplification limited the total cost of construction to under US$100.

  1. Stratigraphy of the unsaturated zone and the Snake River Plain aquifer at and near the Idaho National Engineering Laboratory, Idaho

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, S.R.; Liszewski, M.J.

    1997-08-01

    The unsaturated zone and the Snake River Plain aquifer at and near the Idaho National Engineering Laboratory (INEL) are made up of at least 178 basalt-flow groups, 103 sedimentary interbeds, 6 andesite-flow groups, and 4 rhyolite domes. Stratigraphic units identified in 333 wells in this 890-mile{sup 2} area include 121 basalt-flow groups, 102 sedimentary interbeds, 6 andesite-flow groups, and 1 rhyolite dome. Stratigraphic units were identified and correlated using the data from numerous outcrops and 26 continuous cores and 328 natural-gamma logs available in December 1993. Basalt flows make up about 85% of the volume of deposits underlying the area.

  2. Teaching the Low Level Achiever.

    ERIC Educational Resources Information Center

    Salomone, Ronald E., Ed.

    1986-01-01

    Intended for teachers of the English language arts, the articles in this issue offer suggestions and techniques for teaching the low level achiever. Titles and authors of the articles are as follows: (1) "A Point to Ponder" (Rachel Martin); (2) "Tracking: A Self-Fulfilling Prophecy of Failure for the Low Level Achiever" (James Christopher Davis);…

  3. Extremely low frequency (ELF) stray magnetic fields of laboratory equipment: a possible co-exposure conducting experiments on cell cultures.

    PubMed

    Gresits, Iván; Necz, Péter Pál; Jánossy, Gábor; Thuróczy, György

    2015-09-01

    Measurements of extremely low frequency (ELF) magnetic fields were conducted in the environment of commercial laboratory equipment in order to evaluate the possible co-exposure during the experimental processes on cell cultures. Three types of device were evaluated: a cell culture CO2 incubator, a thermostatic water bath and a laboratory shaker table. These devices usually have electric motors, heating wires and electronic control systems, therefore may expose the cell cultures to undesirable ELF stray magnetic fields. Spatial distributions of magnetic field time domain signal waveform and frequency spectral analysis (FFT) were processed. Long- and short-term variation of stray magnetic field was also evaluated under normal use of investigated laboratory devices. The results show that the equipment under test may add a considerable ELF magnetic field to the ambient environmental magnetic field or to the intentional exposure to ELF, RF or other physical/chemical agents. The maximum stray magnetic fields were higher than 3 µT, 20 µT and 75 µT in the CO2 incubator, in water bath and on the laboratory shaker table, respectively, with high variation of spatial distribution and time domain. Our investigation emphasizes possible confounding factors conducting cell culture studies related to low-level ELF-EMF exposure due to the existing stray magnetic fields in the ambient environment of laboratory equipment.

  4. Numerical assessment of bureau of mines electric arc melter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paik, S.; Hawkes, G.; Nguyen, H.D.

    1994-12-31

    An electric arc melter used for the waste treatment process at Idaho National Engineering Laboratory (INEL) in cooperation with the U.S. Bureau of Mines (USBM) has been numerically studied. The arc melter is being used for vitrification of thermally oxidized, buried, transuranic (TRU) contaminated wastes by INEL in conjunction with the USBM as a part of the Buried Waste Integrated Demonstration project. The purpose of this study is to numerically investigate the performance of the laboratory-scale arc melter simulating the USBM arc melter. Initial results of modeling the full-scale USBM arc melter are also reported in this paper.

  5. Profile of laboratory instruction in secondary school level chemistry and indication for reform

    NASA Astrophysics Data System (ADS)

    Wang, Mei

    This study is a profile of the laboratory component of instruction in secondary school level chemistry. As one of several companion studies, the purpose of the study is to investigate present practices related to instruction as a means of producing reform that improve cognitive and non-cognitive learning outcomes. Five hundred-forty students, from 18 chemistry classes taught by 12 teachers in ten high schools were involved in this study. Three schools included public and private schools, urban school, suburban schools, and rural schools. Three levels or types of chemistry courses were offered in these schools: school regular chemistry for college bound students, Chemistry in the Community or "ChemCom" for non-college bound students, and a second year of chemistry or advanced placement chemistry. Laboratory sessions in each of these three levels of courses were observed, videotaped, and later analyzed using the Modified Revised Science Teachers Behaviors Inventory (MR-STBI). The 12 chemistry teachers, eight science supervisors, and selected students were interviewed to determine their professional backgrounds and other factors that might influence how they teach, how they think, and how they learn. The following conclusions developed from the research are: (1) The three levels of chemistry courses are offered across high schools of varying sizes and locations. (2) Teachers perceive that students come to chemistry classes poorly prepared to effectively carry out laboratory experiences and/or investigations. (3) While students indicated that they are able to effectively use math skills in analyzing the results of chemistry laboratory experiments, teachers, in general, are not satisfied with the level at which students are prepared to use these skills, or to use writing skills. (4) Students working in pairs, is the typical approach. Group cooperation is sometimes used in carrying out the laboratory component of chemistry instruction in the ChemCom and AP chemistry

  6. A Shallow Underground Laboratory for Low-Background Radiation Measurements and Materials Development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aalseth, Craig E.; Bonicalzi, Ricco; Cantaloub, Michael G.

    Abstract: Pacific Northwest National Laboratory recently commissioned a new shallow underground laboratory, located at a depth of approximately 30 meters water-equivalent. This new addition to the small class of radiation measurement laboratories located at modest underground depths worldwide houses the latest generation of custom-made, high-efficiency, low-background gamma-ray spectrometers and gas proportional counters. This manuscript describes the unique capabilities present in the shallow underground laboratory; these include large-scale ultra-pure materials production and a suite of radiation detection systems. Reported data characterize the degree of background reduction achieved through a combination of underground location, graded shielding, and rejection of cosmic-ray events. Wemore » conclude by presenting measurement targets and future opportunities.« less

  7. New Laboratory Course for Senior-Level Chemical Engineering Students

    ERIC Educational Resources Information Center

    Aronson, Mark T.; Deitcher, Robert W.; Xi, Yuanzhou; Davis, Robert J.

    2009-01-01

    A new laboratory course has been developed at the University of Virginia for senior- level chemical engineering students. The new course is based on three 4-week long experiments in bioprocess engineering, energy conversion and catalysis, and polymer synthesis and characterization. The emphasis is on the integration of process steps and the…

  8. Intelligent Mobile Sensor System (IMSS) for drum inspection and monitoring -- Volume 3. Final report, October 1, 1993--April 22, 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    This manual is intended to be read by people who will use the IMSS system on a regular basis, who will be referred to as IMSS system operators. Portions of this manual are intended to be read by operations staff who need to understand certain aspects of the IMSS system since their staff will be working near the IMSS vehicle and docking station. Sections 1 through 4 provide general information of interest both to operations staff and IMSS system operators. The remainder of this manual provides information of interest mainly to IMSS system operators. This manual is customized for usemore » of the IMSS system at the DOE Idaho National Engineering Laboratory (INEL), specifically in Buildings 628 through 634 at INEL`s Radioactive Waste Management Complex (RWMC). The vast majority of this manual is applicable to any installation site--only a few minor details are specific to INEL. This manual will be complemented by one-on-one training provided to INEL personnel by the IMSS system development team.« less

  9. Evaluation of field sampling and preservation methods for strontium-90 in ground water at the Idaho National Engineering Laboratory, Idaho

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cecil, L.D.; Knobel, L.L.; Wegner, S.J.

    1989-09-01

    From 1952 to 1988, about 140 curies of strontium-90 have been discharged in liquid waste to disposal ponds and wells at the INEL (Idaho National Engineering Laboratory). The US Geological Survey routinely samples ground water from the Snake River Plain aquifer and from discontinuous perched-water zones for selected radionuclides, major and minor ions, and chemical and physical characteristics. Water samples for strontium-90 analyses collected in the field are unfiltered and preserved to an approximate 2-percent solution with reagent-grade hydrochloric acid. Water from four wells completed in the Snake River Plain aquifer was sampled as part of the US Geological Survey'smore » quality-assurance program to evaluate the effect of filtration and preservation methods on strontium-90 concentrations in ground water at the INEL. The wells were selected for sampling on the basis of historical concentrations of strontium-90 in ground water. Water from each well was filtered through either a 0.45- or a 0.1-micrometer membrane filter; unfiltered samples also were collected. Two sets of filtered and two sets of unfiltered water samples were collected at each well. One set of water samples was preserved in the field to an approximate 2-percent solution with reagent-grade hydrochloric acid and the other set of samples was not acidified. 13 refs., 2 figs., 6 tabs.« less

  10. 78 FR 1155 - Low-Level Waste Disposal

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-08

    ... NUCLEAR REGULATORY COMMISSION 10 CFR Part 61 [NRC-2011-0012] RIN 3150-AI92 Low-Level Waste... correcting a document appearing in the Federal Register on December 7, 2012 entitled, ``Low-Level Waste... and Submitting Comments, ``Regulatory Analysis for Proposed Revisions to Low-Level Waste Disposal...

  11. The Effect of Grouping by Formal Reasoning Ability, Formal Reasoning Ability Levels, Group Size, and Gender on Achievement in Laboratory Chemistry.

    ERIC Educational Resources Information Center

    Moody, Judith D.; Gifford, Vernon D.

    This study investigated the grouping effect on student achievement in a chemistry laboratory when homogeneous and heterogeneous formal reasoning ability, high and low levels of formal reasoning ability, group sizes of two and four, and homogeneous and heterogeneous gender were used for grouping factors. The sample consisted of all eight intact…

  12. Low-Cost Computer-Controlled Current Stimulator for the Student Laboratory

    ERIC Educational Resources Information Center

    Guclu, Burak

    2007-01-01

    Electrical stimulation of nerve and muscle tissues is frequently used for teaching core concepts in physiology. It is usually expensive to provide every student group in the laboratory with an individual stimulator. This article presents the design and application of a low-cost [about $100 (U.S.)] isolated stimulator that can be controlled by two…

  13. Low-background gamma spectroscopy at the Boulby Underground Laboratory

    NASA Astrophysics Data System (ADS)

    Scovell, P. R.; Meehan, E.; Araújo, H. M.; Dobson, J.; Ghag, C.; Kraus, H.; Kudryavtsev, V. A.; Liu, X.-. R.; Majewski, P.; Paling, S. M.; Preece, R. M.; Saakyan, R.; Tomás, A.; Toth, C.; Yeoman, L. M.

    2018-01-01

    The Boulby Underground Germanium Suite (BUGS) comprises three low-background, high-purity germanium detectors operating in the Boulby Underground Laboratory, located 1.1 km underground in the north-east of England, UK. BUGS utilises three types of detector to facilitate a high-sensitivity, high-throughput radio-assay programme to support the development of rare-event search experiments. A Broad Energy Germanium (BEGe) detector delivers sensitivity to low-energy gamma-rays such as those emitted by 210Pb and 234Th. A Small Anode Germanium (SAGe) well-type detector is employed for efficient screening of small samples. Finally, a standard p-type coaxial detector provides fast screening of standard samples. This paper presents the steps used to characterise the performance of these detectors for a variety of sample geometries, including the corrections applied to account for cascade summing effects. For low-density materials, BUGS is able to radio-assay to specific activities down to 3.6mBqkg-1 for 234Th and 6.6mBqkg-1 for 210Pb both of which have uncovered some significant equilibrium breaks in the 238U chain. In denser materials, where gamma-ray self-absorption increases, sensitivity is demonstrated to specific activities of 0.9mBqkg-1 for 226Ra, 1.1mBqkg-1 for 228Ra, 0.3mBqkg-1 for 224Ra, and 8.6mBqkg-1 for 40K with all upper limits at a 90% confidence level. These meet the requirements of most screening campaigns presently under way for rare-event search experiments, such as the LUX-ZEPLIN (LZ) dark matter experiment. We also highlight the ability of the BEGe detector to probe the X-ray fluorescence region which can be important to identify the presence of radioisotopes associated with neutron production; this is of particular relevance in experiments sensitive to nuclear recoils.

  14. Clinical effectiveness of low-level laser treatment on peripheral somatosensory neuropathy.

    PubMed

    Fallah, Alireza; Mirzaei, Alireza; Gutknecht, Norbert; Demneh, Amir Saberi

    2017-04-01

    Peripheral sensory neuropathy treatment is one of the common treatment problems and causes morbidity and mortality in people suffering from that. Although treatment depends on the underlying cause of the condition, nevertheless, in some cases, there is no cure for it, and it requires palliative and symptomatic treatment. In laboratory studies, low-level laser has been effective in the nerves protection and restoration. The aim of this article is to investigate the clinical efficacy of low-level laser on improvement of the peripheral somatosensory neuropathy. Search in the articles published up to 30 October 2015 (full text and abstracts) in databases PubMed (Medline), Cochrane library, Physiotherapy Evidence Database was performed. The studies of low-level laser trials on patients with peripheral neuropathy were carried out and evaluated in terms of the exclusion criteria. There are 35 articles among which 10 articles had the intended and required criteria. 1, 3, and 6 articles study the patients with diabetes, neuropathy caused by trauma, and carpal tunnel syndrome, respectively. In six studies, laser led to a reduction in sensory impairment and improvement of the physiological function of the sensory nerves. In these articles, lasers (Diode, GaAlAs, He-Ne) had wavelength range 660-860 nm, radiation power 20-250 mW, energy density 0.45-70 J/cm 2 . The intervention sessions range was 6-21 times and patient follow-up was 0-6 months. According to the results of these studies, low-level laser therapy can improve sensory function in patients with peripheral somatosensory neuropathy, although little research have not been done, laser treatment regimens are varied and do not recommend a specific treatment protocol. It seems it requires more research to sum up better, particularly in relation to diabetes.

  15. Acoustical Testing Laboratory Developed to Support the Low-Noise Design of Microgravity Space Flight Hardware

    NASA Technical Reports Server (NTRS)

    Cooper, Beth A.

    2001-01-01

    The NASA John H. Glenn Research Center at Lewis Field has designed and constructed an Acoustical Testing Laboratory to support the low-noise design of microgravity space flight hardware. This new laboratory will provide acoustic emissions testing and noise control services for a variety of customers, particularly for microgravity space flight hardware that must meet International Space Station limits on noise emissions. These limits have been imposed by the space station to support hearing conservation, speech communication, and safety goals as well as to prevent noise-induced vibrations that could impact microgravity research data. The Acoustical Testing Laboratory consists of a 23 by 27 by 20 ft (height) convertible hemi/anechoic chamber and separate sound-attenuating test support enclosure. Absorptive 34-in. fiberglass wedges in the test chamber provide an anechoic environment down to 100 Hz. A spring-isolated floor system affords vibration isolation above 3 Hz. These criteria, along with very low design background levels, will enable the acquisition of accurate and repeatable acoustical measurements on test articles, up to a full space station rack in size, that produce very little noise. Removable floor wedges will allow the test chamber to operate in either a hemi/anechoic or anechoic configuration, depending on the size of the test article and the specific test being conducted. The test support enclosure functions as a control room during normal operations but, alternatively, may be used as a noise-control enclosure for test articles that require the operation of noise-generating test support equipment.

  16. Integration of National Laboratory and Low-Activity Waste Pre-Treatment System Technology Service Providers - 16435

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Subramanian, Karthik H.; Thien, Michael G.; Wellman, Dawn M.

    The National Laboratories are a critical partner and provide expertise in numerous aspects of the successful execution of the Direct-Feed Low Activity Waste Program. The National Laboratories are maturing the technologies of the Low-Activity Waste Pre-Treatment System (LAWPS) consistent with DOE Order 413.3B “Program and Project Management for the Acquisition of Capital Assets” expectations. The National Laboratories continue to mature waste forms, i.e. glass and secondary waste grout, for formulations and predictions of long-term performance as inputs to performance assessments. The working processes with the National Laboratories have been developed in procurements, communications, and reporting to support the necessary delivery-basedmore » technology support. The relationship continues to evolve from planning and technology development to support of ongoing operations and integration of multiple highly coordinated facilities.« less

  17. Rate of strontium sorption and the effects of variable aqueous concentrations of sodium and potassium on strontium distribution coefficients of a surficial sediment at the Idaho National Engineering Laboratory, Idaho

    USGS Publications Warehouse

    Bunde, R.L.; Rosentreter, J.J.; Liszewski, M.J.

    1998-01-01

    The rate of strontium sorption and the effects of variable aqueous concentrations of sodium and potassium on strontium sorption were measured as part of an investigation to determine strontium chemical transport properties of a surficial sediment at the Idaho National Engineering Laboratory (INEL), Idaho. Batch experimental techniques were used to determine the rate of strontium sorption and strontium distribution coefficients (K(d)s) between aqueous and solid phases. Rate experiments indicate that strontium in solution reached an apparent equilibrium with the sediment in 26 h. K(d)s were derived using the linear isotherm model at initial sodium concentrations from 100 to 5,000 mg/l and initial potassium concentrations from 2 to 150 mg/l. K(d)s ranged from 56 ?? 2 to 62 ?? 3 ml/g at initial aqueous concentrations of sodium and potassium equal to or less than 300 and 150 mg/l, respectively. K(d)s hinged from 4.7 ?? 0.2 to 19 ?? 1 ml/g with initial aqueous concentrations of sodium between 1,000 and 5,000 mg/l. These data indicate that sodium concentrations greater than 300 mg/l in wastewater increase the availability of strontium for transport beneath waste disposal ponds at the INEL by decreasing strontium sorption on the surficial sediment. Wastewater concentrations of sodium and potassium less than 300 and 150 mg/l, respectively, have little effect on the availability of strontium for transport.The rate of strontium sorption and the effects of variable aqueous concentrations of sodium and potassium on strontium sorption were measured as part of an investigation to determine strontium chemical transport properties of a surficial sediment at the Idaho National Engineering Laboratory (INEL), Idaho. Batch experimental techniques were used to determine the rate of strontium sorption and strontium distribution coefficients (Kds) between aqueous and solid phases. Rate experiments indicate that strontium in solution reached an apparent equilibrium with the sediment in 26

  18. [Quality control assessments of feces examination for schistosomiasis in province-level laboratories of Zhejiang Province].

    PubMed

    Chen, Wen; Zhu, Ming-Dong; Yan, Xiao-Lan; Lin, Li-Jun; Zhang, Jian-Feng; Li, Li; Wen, Li-Yong

    2011-06-01

    To understand and evaluate the quality of feces examination for schistosomiasis in province-level laboratories of Zhejiang Province. With the single-blind method, the stool samples were detected by the stool hatching method and sediment detection method. In the 3 quality control assessments in 2006, 2008 and 2009, most laboratories finished the examinations on time. The accordance rates of detections were 88.9%, 100% and 93.9%, respectively. The province-level laboratories for schistosomiasis feces examination of Zhejiang Province is coming into standardization, and the techniques of schistosomiasis feces examination are optimized gradually.

  19. Low-level mechanisms for processing odor information in the behaving animal.

    PubMed

    Wachowiak, Matt; Wesson, Daniel W; Pírez, Nicolás; Verhagen, Justus V; Carey, Ryan M

    2009-07-01

    Sensory processing is typically thought to act on representations of sensory stimuli that are relatively fixed at low levels in the nervous system and become increasingly complex and subject to modulation at higher levels. Here we present recent findings from our laboratory demonstrating that, in the olfactory system, odor representations in the behaving animal can be transformed at low levels--as early as the primary sensory neurons themselves--via a variety of mechanisms. First, changes in odor sampling behavior, such as sniffing, can dramatically and rapidly alter primary odor representations by changing the strength and temporal structure of sensory input to the olfactory bulb, effectively shaping which features of the olfactory landscape are emphasized and likely altering how information is processed by the olfactory bulb network. Second, neural substrates exist for presynaptically modulating the strength of sensory input to the bulb as a function of behavioral state. The systems most likely to be involved in this modulation--cholinergic and serotonergic centrifugal inputs to the bulb--are linked to attention and arousal effects in other brain areas. Together, sniffing behavior and presynaptic inhibition have the potential to mediate, or at least contribute to, sensory processing phenomena, such as figure-ground separation, intensity invariance, and context-dependent and attentional modulation of response properties. Thus, "high order" processing can occur even before sensory neurons transmit information to the brain.

  20. Laboratory testing of GNB switch 12 volt SLI (starting, lighting and ignition) battery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hardin, J.E.

    1990-03-01

    The purpose of this report is to describe the testing performed on the GNB Switch flooded lead SLI battery in the INEL Electric Vehicle Battery Laboratory, to present the results and conclusions of this testing, and to make appropriate recommendations. GNB Inc. is a Pacific Dunlop Company. The term SWITCH'' comes from the fact that this product consists of two batteries in one package which can be connected in parallel by a switch for higher cranking energy or reserve capacity. The smaller second battery is float charged through a diode. GNB advertising describes the SWITCH'' as The Battery With Amore » Spare''. The Switch, a BCI Group 24 SLI (Starting, Lighting and Ignition) battery, is manufactured in Georgia for sale throughout the US. The initial design work on the Switch was done in Australia under the Pulsar name by Dunlop. 11 figs., 3 tabs.« less

  1. Design and Study of a Low-Cost Laboratory Model Digital Wind Power Meter

    ERIC Educational Resources Information Center

    Radhakrishnan, Rugmini; Karthika, S.

    2010-01-01

    A vane-type low-cost laboratory model anemometer cum power meter is designed and constructed for measuring low wind energy created from accelerating fluids. The constructed anemometer is a device which records the electrical power obtained by the conversion of wind power using a wind sensor coupled to a DC motor. It is designed for its…

  2. Evaluation of uranium removal by Hydrilla verticillata (L.f.) Royle from low level nuclear waste under laboratory conditions.

    PubMed

    Srivastava, Sudhakar; Bhainsa, K C

    2016-02-01

    The present study evaluated uranium (U) removal ability and tolerance to low level nuclear waste (LLNW) of an aquatic weed Hydrilla verticillata. Plants were screened for growth in 10%-50% waste treatments up to 3 d. Treatments of 20% and 50% waste imposed increasing toxicity with duration assessed in terms of change in fresh weight and in the levels of photosynthetic pigments and thiobarbituric acid-reactive substances. U concentration, however, did not show a progressive increase and was about 42 μg g(-1) dw from 20% to 50% waste at 3 d. This suggested that a saturation stage was reached with respect to U removal due to increasing toxicity. However, in another experiment with 10% waste and 10% waste+10 ppm U treatments, plants showed an increase in U concentration with the maximum level approaching 426 μg g(-1) dw at 3 d without showing any toxicity as compared to that at 20% and 50% waste treatments. Hence, plants possessed significant potential to take up U and toxicity of LLNW limited their U removal ability. This implies that the use of Hydrilla plants for U removal from LLNW is feasible at low concentrations and would require repeated harvesting at short intervals. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Exploring students' interactions, arguments, and reflections in general chemistry laboratories with different levels of inquiry

    NASA Astrophysics Data System (ADS)

    Xu, Haozhi

    Students' learning in inquiry-based investigations has drawn considerable attention of the science education community. Inquiry activities can be viewed as knowledge construction processes in which students are expected to develop conceptual understanding and critical thinking abilities. Our study aimed to explore the effect of experiments with different levels of inquiry on students' interactions in the laboratory setting, as well as on students' written arguments and reflections. Our results are based on direct observations of group work in college general chemistry laboratories and analysis of associated written lab reports. The analysis of students' interactions in the laboratory was approached from three major analytic dimensions: Functional analysis, cognitive processing, and social processing. According to our results, higher levels of inquiry were associated with an increase in the relative frequency of episodes where students were engaged in proposing ideas versus asking and answering each others' questions. Higher levels of inquiry also favored episodes in which experimental work was approached in a more exploratory (versus procedural) manner. However, no major changes were observed in the extent to which students were engaged in either interpretive discussions of central scientific concepts and ideas. As part of our study we were also interested in characterizing the effects of experiments involving different levels of inquiry on the structure and adequacy of university general chemistry students' written arguments, as well as on the nature of their reflections about laboratory work. Our findings indicate that the level of inquiry of the observed experiments had no significant impact on the structure or adequacy of arguments generated by students. However, the level of inquiry of the experiments seemed to have a major impact on several areas of students' written reflections about laboratory work. In general, our results elicit trends and highlight issues

  4. Extremely low-level microwaves attenuate immune imbalance induced by inhalation exposure to low-level toluene in mice.

    PubMed

    Novoselova, Elena G; Glushkova, Olga V; Khrenov, Maxim O; Novoselova, Tatyana V; Lunin, Sergey M; Fesenko, Eugeny E

    2017-05-01

    To clarify whether extremely low-level microwaves (MW) alone or in combination with p38 inhibitor affect immune cell responses to inhalation exposure of mice to low-level toluene. The cytokine profile, heat shock proteins expression, and the activity of several signal cascades, namely, NF-κB, SAPK/JNK, IRF-3, p38 MAPK, and TLR4 were measured in spleen lymphocytes of mice treated to air-delivered toluene (0.6 mg/m 3 ) or extremely low-level microwaves (8.15-18 GHz, 1μW/cm 2 , 1 Hz swinging frequency) or combined action of these two factors. A single exposure to air-delivered low-level toluene induced activation of NF-κB, SAPK/JNK, IFR-3, p38 MAPK and TLR4 pathways. Furthermore, air toluene induced the expression of Hsp72 and enhanced IL-1, IL-6, and TNF-α in blood plasma, which is indicative of a pro-inflammatory response. Exposure to MW alone also resulted in the enhancement of the plasma cytokine values (e.g. IL-6, TNF-α, and IFN-γ) and activation of the NF-κB, MAPK p38, and especially the TLR4 pathways in splenic lymphocytes. Paradoxically, pre-exposure to MW partially recovered or normalized the lymphocyte parameters in the toluene-exposed mice, while the p38 inhibitor XI additionally increased protective activity of microwaves by down regulating MAPKs (JNK and p38), IKK, as well as expression of TLR4 and Hsp90-α. The results suggest that exposure to low-intensity MW at specific conditions may recover immune parameters in mice undergoing inhalation exposure to low-level toluene via mechanisms involving cellular signaling.

  5. Site-specific probabilistic seismic hazard analyses for the Idaho National Engineering Laboratory. Volume 2: Appendices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-05-01

    The identification of seismic sources is often based on a combination of geologic and tectonic considerations and patterns of observed seismicity; hence, a historical earthquake catalogue is important. A historical catalogue of earthquakes of approximate magnitude (M) 2.5 and greater for the time period 1850 through 1992 was compiled for the INEL region. The primary data source used was the Decade of North American Geology (DNAG) catalogue for the time period from about 1800 through 1985 (Engdahl and Rinehart, 1988). A large number of felt earthquakes, especially prior to the 1970`s, which were below the threshold of completeness established inmore » the DNAG catalogue (Engdahl and Rinehart, 1991), were taken from the state catalogues compiled by Stover and colleagues at the National Earthquake Information Center (NEIC) and combined with the DNAG catalogue for the INEL region. The state catalogues were those of Idaho, Montana, Nevada, Utah, and Wyoming. NEIC`s Preliminary Determination of Epicenters (PDE) and the state catalogues compiled by the Oregon Department of Geology and Mineral Industries (DOGAMI), and the University of Nevada at Reno (UNR) were also used to supplement the pre-1986 time period. A few events reanalyzed by Jim Zollweg (Boise State University, written communication, 1994) were also modified in the catalogue. In the case of duplicate events, the DNAG entry was preferred over the Stover et al. entry for the period 1850 through 1985. A few events from Berg and Baker (1963) were also added to the catalogue. This information was and will be used in determining the seismic risk of buildings and facilities located at the Idaho National Engineering Laboratory.« less

  6. Idaho National Engineering Laboratory code assessment of the Rocky Flats transuranic waste

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-07-01

    This report is an assessment of the content codes associated with transuranic waste shipped from the Rocky Flats Plant in Golden, Colorado, to INEL. The primary objective of this document is to characterize and describe the transuranic wastes shipped to INEL from Rocky Flats by item description code (IDC). This information will aid INEL in determining if the waste meets the waste acceptance criteria (WAC) of the Waste Isolation Pilot Plant (WIPP). The waste covered by this content code assessment was shipped from Rocky Flats between 1985 and 1989. These years coincide with the dates for information available in themore » Rocky Flats Solid Waste Information Management System (SWIMS). The majority of waste shipped during this time was certified to the existing WIPP WAC. This waste is referred to as precertified waste. Reassessment of these precertified waste containers is necessary because of changes in the WIPP WAC. To accomplish this assessment, the analytical and process knowledge available on the various IDCs used at Rocky Flats were evaluated. Rocky Flats sources for this information include employee interviews, SWIMS, Transuranic Waste Certification Program, Transuranic Waste Inspection Procedure, Backlog Waste Baseline Books, WIPP Experimental Waste Characterization Program (headspace analysis), and other related documents, procedures, and programs. Summaries are provided of: (a) certification information, (b) waste description, (c) generation source, (d) recovery method, (e) waste packaging and handling information, (f) container preparation information, (g) assay information, (h) inspection information, (i) analytical data, and (j) RCRA characterization.« less

  7. Laboratory and field tests of the Sutron RLR-0003-1 water level sensor

    USGS Publications Warehouse

    Fulford, Janice M.; Bryars, R. Scott

    2015-01-01

    Three Sutron RLR-0003-1 water level sensors were tested in laboratory conditions to evaluate the accuracy of the sensor over the manufacturer’s specified operating temperature and distance-to-water ranges. The sensor was also tested for compliance to SDI-12 communication protocol and in field conditions at a U.S. Geological Survey (USGS) streamgaging site. Laboratory results were compared to the manufacturer’s accuracy specification for water level and to the USGS Office of Surface Water (OSW) policy requirement that water level sensors have a measurement uncertainty of no more than 0.01 foot or 0.20 percent of the indicated reading. Except for one sensor, the differences for the temperature testing were within 0.05 foot and the average measurements for the sensors were within the manufacturer’s accuracy specification. Two of the three sensors were within the manufacturer’s specified accuracy and met the USGS accuracy requirements for the laboratory distance to water testing. Three units passed a basic SDI-12 communication compliance test. Water level measurements made by the Sutron RLR-0003-1 during field testing agreed well with those made by the bubbler system and a Design Analysis Associates (DAA) H3613 radar, and they met the USGS accuracy requirements when compared to the wire-weight gage readings.

  8. Laboratory Measurement Implications of Decreasing Childhood Blood Lead Levels

    PubMed Central

    Caldwell, Kathleen L.; Cheng, Po-Yung; Jarrett, Jeffery M.; Makhmudov, Amir; Vance, Kathryn; Ward, Cynthia D.; Jones, Robert L.; Mortensen, Mary E.

    2017-01-01

    In 2012, the Centers for Disease Control and Prevention (CDC) adopted its Advisory Committee on Childhood Lead Poisoning Prevention (ACCLPP) recommendation to use a population-based reference value to identify children and environments associated with lead hazards. The current reference value of 5 μg/dL is calculated as the 97.5th percentile of the distribution of blood lead levels (BLL) in children one to five years old from 2007–2010 National Health and Nutrition Examination Survey (NHANES) data. We calculated and updated selected percentiles, including the 97.5th percentile, using NHANES 2011–2014 blood lead data and examined demographic characteristics of children whose blood lead was ≥90th percentile value. The 97.5% percentile BLL of 3.48 μg/dL highlighted analytical laboratory and clinical interpretation challenges of blood lead measurements ≤ 5 μg/dL. Review of five years of results for target blood lead values < 11 μg/dL for U.S. clinical laboratories participating in CDC’s voluntary Lead and Multi-Element Proficiency (LAMP) quality assurance program showed 40% unable to quantify and reported a non-detectable result at a target blood lead value of 1.48 μg/dL compared 5.5 % at a target blood lead of 4.60 μg/dL. We describe actions taken at CDC’s Environmental Health Laboratory in the Division of Laboratory Sciences, which measures blood lead for NHANES, to improve analytical accuracy and precision and to reduce external lead contamination during blood collection and analysis. PMID:28771411

  9. Tethered variable gravity laboratory study: Low gravity process identification report

    NASA Technical Reports Server (NTRS)

    Briccarello, M.

    1989-01-01

    Experiments are described performable in the variable gravity environment, and the related compatible/beneficial residual accelerations, both for pure and applied research in the fields of Fluid Mechanics (static and dynamic), Materials Sciences (Crystal Growth, Metal and Alloy Solidification, Glasses, etc.), and Life Sciences, so as to assess the relevance of a variable G-level laboratory.

  10. Factors associated with biosafety level-2 research workers' laboratory exit handwashing behaviors and glove removal compliance.

    PubMed

    Johnston, James D; Merrill, Ray M; Zimmerman, Grant C; Collingwood, Scott C; Reading, James C

    2016-01-01

    Biosafety level-2 laboratories are designated for work with human-derived samples or moderate-risk microorganisms that transmit primarily by direct contact exposures. Many laboratory procedures generate unseen droplets that contaminate workers' hands, equipment, and work surfaces. Workers' strict adherence to glove removal and handwashing is required prior to laboratory exit to prevent inadvertent transmission of pathogens to self or others. However, little is known about biosafety level-2 workers' compliance with these behaviors. In this article, glove removal and handwashing compliance upon laboratory exit were measured by direct observation of 93 biosafety level-2 research workers from 21 university laboratories. Participants completed a 41-item survey measuring social cognitive theory-based variables related to handwashing, self-reported compliance, and demographic factors. Survey items, observed exit frequency, and laboratory characteristics were evaluated for associations with handwashing compliance. Overall, observed glove removal and handwashing compliance upon laboratory exit were 43.0% (Standard Error [SE] = 2.3%), and 8.2% (SE = 1.2%), respectively, while workers' self-reported glove removal and handwashing compliance were 73.7% (SE = 3.6%) and 35.5% (SE = 4.1%), respectively. The average number of observed laboratory exits per hour was 2.8 for workers with any handwashing compliance vs. 5.4 for workers with no handwashing compliance (p = 0.0013). Among the cognitive variables, behavioral modeling by supervisors and coworkers had the strongest association with workers' compliance (slope = 3.5, SE = 1.3, p = 0.0113). Workers in laboratories with a written handwashing policy had higher compliance (Mean = 14.1%, SE = 5.9%) than workers in laboratories with no written policy (Mean = 1.1%, SE = 1.0%; p = 0.0488). Multi-faceted interventions that encourage modeling of the behavior by supervisors and coworkers, implementation of written handwashing policies

  11. Fast, Low-Power, Hysteretic Level-Detector Circuit

    NASA Technical Reports Server (NTRS)

    Arditti, Mordechai

    1993-01-01

    Circuit for detection of preset levels of voltage or current intended to replace standard fast voltage comparator. Hysteretic analog/digital level detector operates at unusually low power with little sacrifice of speed. Comprises low-power analog circuit and complementary metal oxide/semiconductor (CMOS) digital circuit connected in overall closed feedback loop to decrease rise and fall times, provide hysteresis, and trip-level control. Contains multiple subloops combining linear and digital feedback. Levels of sensed signals and hysteresis level easily adjusted by selection of components to suit specific application.

  12. Low level vapor verification of monomethyl hydrazine

    NASA Technical Reports Server (NTRS)

    Mehta, Narinder

    1990-01-01

    The vapor scrubbing system and the coulometric test procedure for the low level vapor verification of monomethyl hydrazine (MMH) are evaluated. Experimental data on precision, efficiency of the scrubbing liquid, instrument response, detection and reliable quantitation limits, stability of the vapor scrubbed solution, and interference were obtained to assess the applicability of the method for the low ppb level detection of the analyte vapor in air. The results indicated that the analyte vapor scrubbing system and the coulometric test procedure can be utilized for the quantitative detection of low ppb level vapor of MMH in air.

  13. An improved method of chemical analysis for low levels of nitrogen in forest streams or in rainwater.

    Treesearch

    Elly E. Holcombe; Duane G. Moore; Richard L. Fredriksen

    1986-01-01

    A modification of the macro-Kjeldahl method that provides increased sensitivity was developed for determining very low levels of nitrogen in forest streams and in rain-water. The method is suitable as a routine laboratory procedure. Analytical range of the method is 0.02 to 1.5 mg/L with high recovery and excellent precision and ac-curacy. The range can be increased to...

  14. Framework for leadership and training of Biosafety Level 4 laboratory workers.

    PubMed

    Le Duc, James W; Anderson, Kevin; Bloom, Marshall E; Estep, James E; Feldmann, Heinz; Geisbert, Joan B; Geisbert, Thomas W; Hensley, Lisa; Holbrook, Michael; Jahrling, Peter B; Ksiazek, Thomas G; Korch, George; Patterson, Jean; Skvorak, John P; Weingartl, Hana

    2008-11-01

    Construction of several new Biosafety Level 4 (BSL-4) laboratories and expansion of existing operations have created an increased international demand for well-trained staff and facility leaders. Directors of most North American BSL-4 laboratories met and agreed upon a framework for leadership and training of biocontainment research and operations staff. They agreed on essential preparation and training that includes theoretical consideration of biocontainment principles, practical hands-on training, and mentored on-the-job experiences relevant to positional responsibilities as essential preparation before a person's independent access to a BSL-4 facility. They also agreed that the BSL-4 laboratory director is the key person most responsible for ensuring that staff members are appropriately prepared for BSL-4 operations. Although standardized certification of training does not formally exist, the directors agreed that facility-specific, time-limited documentation to recognize specific skills and experiences of trained persons is needed.

  15. Customer satisfaction survey with clinical laboratory and phlebotomy services at a tertiary care unit level.

    PubMed

    Koh, Young Rae; Kim, Shine Young; Kim, In Suk; Chang, Chulhun L; Lee, Eun Yup; Son, Han Chul; Kim, Hyung Hoi

    2014-09-01

    We performed customer satisfaction surveys for physicians and nurses regarding clinical laboratory services, and for outpatients who used phlebotomy services at a tertiary care unit level to evaluate our clinical laboratory and phlebotomy services. Thus, we wish to share our experiences with the customer satisfaction survey for clinical laboratory and phlebotomy services. Board members of our laboratory designed a study procedure and study population, and developed two types of questionnaire. A satisfaction survey for clinical laboratory services was conducted with 370 physicians and 125 nurses by using an online or paper questionnaire. The satisfaction survey for phlebotomy services was performed with 347 outpatients who received phlebotomy services by using computer-aided interviews. Mean satisfaction scores of physicians and nurses was 58.1, while outpatients' satisfaction score was 70.5. We identified several dissatisfactions with our clinical laboratory and phlebotomy services. First, physicians and nurses were most dissatisfied with the specimen collection and delivery process. Second, physicians and nurses were dissatisfied with phlebotomy services. Third, molecular genetic and cytogenetic tests were found more expensive than other tests. This study is significant in that it describes the first reference survey that offers a survey procedure and questionnaire to assess customer satisfaction with clinical laboratory and phlebotomy services at a tertiary care unit level.

  16. Customer Satisfaction Survey With Clinical Laboratory and Phlebotomy Services at a Tertiary Care Unit Level

    PubMed Central

    Koh, Young Rae; Kim, Shine Young; Kim, In Suk; Chang, Chulhun L.; Lee, Eun Yup; Son, Han Chul

    2014-01-01

    We performed customer satisfaction surveys for physicians and nurses regarding clinical laboratory services, and for outpatients who used phlebotomy services at a tertiary care unit level to evaluate our clinical laboratory and phlebotomy services. Thus, we wish to share our experiences with the customer satisfaction survey for clinical laboratory and phlebotomy services. Board members of our laboratory designed a study procedure and study population, and developed two types of questionnaire. A satisfaction survey for clinical laboratory services was conducted with 370 physicians and 125 nurses by using an online or paper questionnaire. The satisfaction survey for phlebotomy services was performed with 347 outpatients who received phlebotomy services by using computer-aided interviews. Mean satisfaction scores of physicians and nurses was 58.1, while outpatients' satisfaction score was 70.5. We identified several dissatisfactions with our clinical laboratory and phlebotomy services. First, physicians and nurses were most dissatisfied with the specimen collection and delivery process. Second, physicians and nurses were dissatisfied with phlebotomy services. Third, molecular genetic and cytogenetic tests were found more expensive than other tests. This study is significant in that it describes the first reference survey that offers a survey procedure and questionnaire to assess customer satisfaction with clinical laboratory and phlebotomy services at a tertiary care unit level. PMID:25187892

  17. Implementing and measuring the level of laboratory service integration in a program setting in Nigeria.

    PubMed

    Mbah, Henry; Negedu-Momoh, Olubunmi Ruth; Adedokun, Oluwasanmi; Ikani, Patrick Anibbe; Balogun, Oluseyi; Sanwo, Olusola; Ochei, Kingsley; Ekanem, Maurice; Torpey, Kwasi

    2014-01-01

    The surge of donor funds to fight HIV&AIDS epidemic inadvertently resulted in the setup of laboratories as parallel structures to rapidly respond to the identified need. However these parallel structures are a threat to the existing fragile laboratory systems. Laboratory service integration is critical to remedy this situation. This paper describes an approach to quantitatively measure and track integration of HIV-related laboratory services into the mainstream laboratory services and highlight some key intervention steps taken, to enhance service integration. A quantitative before-and-after study conducted in 122 Family Health International (FHI360) supported health facilities across Nigeria. A minimum service package was identified including management structure; trainings; equipment utilization and maintenance; information, commodity and quality management for laboratory integration. A check list was used to assess facilities at baseline and 3 months follow-up. Level of integration was assessed on an ordinal scale (0 = no integration, 1 = partial integration, 2 = full integration) for each service package. A composite score grading expressed as a percentage of total obtainable score of 14 was defined and used to classify facilities (≤ 80% FULL, 25% to 79% PARTIAL and <25% NO integration). Weaknesses were noted and addressed. We analyzed 9 (7.4%) primary, 104 (85.2%) secondary and 9 (7.4%) tertiary level facilities. There were statistically significant differences in integration levels between baseline and 3 months follow-up period (p<0.01). Baseline median total integration score was 4 (IQR 3 to 5) compared to 7 (IQR 4 to 9) at 3 months follow-up (p = 0.000). Partial and fully integrated laboratory systems were 64 (52.5%) and 0 (0.0%) at baseline, compared to 100 (82.0%) and 3 (2.4%) respectively at 3 months follow-up (p = 0.000). This project showcases our novel approach to measure the status of each laboratory on the integration continuum.

  18. 77 FR 72997 - Low-Level Waste Disposal

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-07

    ...-2011-0012] RIN 3150-AI92 Low-Level Waste Disposal AGENCY: Nuclear Regulatory Commission. ACTION... Regulatory Commission (NRC) is proposing to amend its regulations that govern low-level radioactive waste... development of criteria for waste acceptance based on the results of these analyses. These amendments will...

  19. Low-level exposure to radiofrequency electromagnetic fields: health effects and research needs.

    PubMed

    Repacholi, M H

    1998-01-01

    The World Health Organization (WHO), the International Commission on Non-Ionizing Radiation Protection (ICNIRP), and the German and Austrian Governments jointly sponsored an international seminar in November of 1996 on the biological effects of low-level radiofrequency (RF) electromagnetic fields. For purposes of this seminar, RF fields having frequencies only in the range of about 10 MHz to 300 GHz were considered. This is one of a series of scientific review seminars held under the International Electromagnetic Field (EMF) Project to identify any health hazards from EMF exposure. The scientific literature was reviewed during the seminar and expert working groups formed to provide a status report on possible health effects from exposure to low-level RF fields and identify gaps in knowledge requiring more research to improve health risk assessments. It was concluded that, although hazards from exposure to high-level (thermal) RF fields were established, no known health hazards were associated with exposure to RF sources emitting fields too low to cause a significant temperature rise in tissue. Biological effects from low-level RF exposure were identified needing replication and further study. These included in vitro studies of cell kinetics and proliferation effects, effects on genes, signal transduction effects and alterations in membrane structure and function, and biophysical and biochemical mechanisms for RF field effects. In vivo studies should focus on the potential for cancer promotion, co-promotion and progression, as well as possible synergistic, genotoxic, immunological, and carcinogenic effects associated with chronic low-level RF exposure. Research is needed to determine whether low-level RF exposure causes DNA damage or influences central nervous system function, melatonin synthesis, permeability of the blood brain barrier (BBB), or reaction to neurotropic drugs. Reported RF-induced changes to eye structure and function should also be investigated

  20. Evolution of high-level resistance during low-level antibiotic exposure.

    PubMed

    Wistrand-Yuen, Erik; Knopp, Michael; Hjort, Karin; Koskiniemi, Sanna; Berg, Otto G; Andersson, Dan I

    2018-04-23

    It has become increasingly clear that low levels of antibiotics present in many environments can select for resistant bacteria, yet the evolutionary pathways for resistance development during exposure to low amounts of antibiotics remain poorly defined. Here we show that Salmonella enterica exposed to sub-MIC levels of streptomycin evolved high-level resistance via novel mechanisms that are different from those observed during lethal selections. During lethal selection only rpsL mutations are found, whereas at sub-MIC selection resistance is generated by several small-effect resistance mutations that combined confer high-level resistance via three different mechanisms: (i) alteration of the ribosomal RNA target (gidB mutations), (ii) reduction in aminoglycoside uptake (cyoB, nuoG, and trkH mutations), and (iii) induction of the aminoglycoside-modifying enzyme AadA (znuA mutations). These results demonstrate how the strength of the selective pressure influences evolutionary trajectories and that even weak selective pressures can cause evolution of high-level resistance.

  1. Erratum: "Low vibration laboratory with a single-stage vibration isolation for microscopy applications" [Rev. Sci. Instrum. 88, 023703 (2017)

    NASA Astrophysics Data System (ADS)

    Voigtländer, Bert; Coenen, Peter; Cherepanov, Vasily; Borgens, Peter; Duden, Thomas; Tautz, F. Stefan

    2018-01-01

    The construction and the vibrational performance of a low vibration laboratory for microscopy applications comprising a 100 ton floating foundation supported by passive pneumatic isolators (air springs), which rest themselves on a 200 ton solid base plate is discussed. The optimization of the air spring system lead to a vibration level on the floating floor below that induced by an acceleration of 10 ng for most frequencies. Additional acoustic and electromagnetic isolation is accomplished by a room-in-room concept.

  2. Laboratory based instruction in Pakistan: Comparative evaluation of three laboratory instruction methods in biological science at higher secondary school level

    NASA Astrophysics Data System (ADS)

    Cheema, Tabinda Shahid

    This study of laboratory based instruction at higher secondary school level was an attempt to gain some insight into the effectiveness of three laboratory instruction methods: cooperative group instruction method, individualised instruction method and lecture demonstration method on biology achievement and retention. A Randomised subjects, Pre-test Post-test Comparative Methods Design was applied. Three groups of students from a year 11 class in Pakistan conducted experiments using the different laboratory instruction methods. Pre-tests, achievement tests after the experiments and retention tests one month later were administered. Results showed no significant difference between the groups on total achievement and retention, nor was there any significant difference on knowledge and comprehension test scores or skills performance. Future research investigating a similar problem is suggested.

  3. Application of Low level Lasers in Dentistry (Endodontic)

    PubMed Central

    Asnaashari, Mohammad; Safavi, Nassimeh

    2013-01-01

    Low level lasers, cold or soft lasers: These lasers do not produce thermal effects on tissues and induce photoreactions in cells through light stimulation which is called photobiostimulation. Power of these lasers is usually under 250mW. The main point differentiating low level lasers and high power ones is the activation of photochemical reactions without heat formation. The most important factor to achieve this light characteristic in lasers is not their power, but their power density for each surfa ceunit (i.e cm2). Density lower than 670mW/cm2, can induce the stimulatory effects of low level lasers without thermal effects. Low level lasers (therapeutic) used today as treatment adjunctive devices in medicine and dentistry. Numerous studies have been performed on the applications of low level lasers in patient pain reduction. Mechanisms of pain reduction with therapeutic lasers and their application are expressed, and the studies realized in this field are presented. PMID:25606308

  4. Framework for Leadership and Training of Biosafety Level 4 Laboratory Workers

    PubMed Central

    Anderson, Kevin; Bloom, Marshall E.; Estep, James E.; Feldmann, Heinz; Geisbert, Joan B.; Geisbert, Thomas W.; Hensley, Lisa; Holbrook, Michael; Jahrling, Peter B.; Ksiazek, Thomas G.; Korch, George; Patterson, Jean; Skvorak, John P.; Weingartl, Hana

    2008-01-01

    Construction of several new Biosafety Level 4 (BSL-4) laboratories and expansion of existing operations have created an increased international demand for well-trained staff and facility leaders. Directors of most North American BSL-4 laboratories met and agreed upon a framework for leadership and training of biocontainment research and operations staff. They agreed on essential preparation and training that includes theoretical consideration of biocontainment principles, practical hands-on training, and mentored on-the-job experiences relevant to positional responsibilities as essential preparation before a person’s independent access to a BSL-4 facility. They also agreed that the BSL-4 laboratory director is the key person most responsible for ensuring that staff members are appropriately prepared for BSL-4 operations. Although standardized certification of training does not formally exist, the directors agreed that facility-specific, time-limited documentation to recognize specific skills and experiences of trained persons is needed. PMID:18976549

  5. Incorporating Human Readiness Levels at Sandia National Laboratories

    DOE PAGES

    See, Judi E.; Morris, Jason; Craft, Richard; ...

    2018-01-24

    Since 2010, the concept of human readiness levels has been under development as a possible supplement to the existing technology readiness level (TRL) scale. The intent is to provide a mechanism to address safety and performance risks associated with the human component in a system that parallels the TRL structure already familiar to the systems engineering community. Sandia National Laboratories in Albuquerque, New Mexico, initiated a study in 2015 to evaluate options to incorporate human readiness planning for Sandia processes and products. The study team has collected the majority of baseline assessment data and has conducted interviews to understand staffmore » perceptions of four different options for human readiness planning. Preliminary results suggest that all four options may have a vital role, depending on the type of work performed and the phase of product development. Upon completion of data collection, the utility of identified solutions will be assessed in one or more test cases.« less

  6. Incorporating Human Readiness Levels at Sandia National Laboratories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    See, Judi E.; Morris, Jason; Craft, Richard

    Since 2010, the concept of human readiness levels has been under development as a possible supplement to the existing technology readiness level (TRL) scale. The intent is to provide a mechanism to address safety and performance risks associated with the human component in a system that parallels the TRL structure already familiar to the systems engineering community. Sandia National Laboratories in Albuquerque, New Mexico, initiated a study in 2015 to evaluate options to incorporate human readiness planning for Sandia processes and products. The study team has collected the majority of baseline assessment data and has conducted interviews to understand staffmore » perceptions of four different options for human readiness planning. Preliminary results suggest that all four options may have a vital role, depending on the type of work performed and the phase of product development. Upon completion of data collection, the utility of identified solutions will be assessed in one or more test cases.« less

  7. Fruit Flies Provide New Insights in Low-Radiation Background Biology at the INFN Underground Gran Sasso National Laboratory (LNGS).

    PubMed

    Morciano, Patrizia; Cipressa, Francesca; Porrazzo, Antonella; Esposito, Giuseppe; Tabocchini, Maria Antonella; Cenci, Giovanni

    2018-06-04

    Deep underground laboratories (DULs) were originally created to host particle, astroparticle or nuclear physics experiments requiring a low-background environment with vastly reduced levels of cosmic-ray particle interference. More recently, the range of science projects requiring an underground experiment site has greatly expanded, thus leading to the recognition of DULs as truly multidisciplinary science sites that host important studies in several fields, including geology, geophysics, climate and environmental sciences, technology/instrumentation development and biology. So far, underground biology experiments are ongoing or planned in a few of the currently operating DULs. Among these DULs is the Gran Sasso National Laboratory (LNGS), where the majority of radiobiological data have been collected. Here we provide a summary of the current scenario of DULs around the world, as well as the specific features of the LNGS and a summary of the results we obtained so far, together with other findings collected in different underground laboratories. In particular, we focus on the recent results from our studies of Drosophila melanogaster, which provide the first evidence of the influence of the radiation environment on life span, fertility and response to genotoxic stress at the organism level. Given the increasing interest in this field and the establishment of new projects, it is possible that in the near future more DULs will serve as sites of radiobiology experiments, thus providing further relevant biological information at extremely low-dose-rate radiation. Underground experiments can be nicely complemented with above-ground studies at increasing dose rate. A systematic study performed in different exposure scenarios provides a potential opportunity to address important radiation protection questions, such as the dose/dose-rate relationship for cancer and non-cancer risk, the possible existence of dose/dose-rate threshold(s) for different biological systems and

  8. LSBB: a Low Noise Laboratory for Inter--Disciplinary Underground Science and Technology in Rustrel--Pays d'Apt, Vaucluse, France

    NASA Astrophysics Data System (ADS)

    Gaffet, S.

    2008-12-01

    Located in the Provence-Alpes--Côte d'Azur region (Southern France), LSBB is an underground facility that is dedicated since 10 years ago, to interdisciplinary fundamental and applied R&D activities in a low level anthropogenic area that secures the site with one of the lowest environmental noise in the world. LSBB is both a host-laboratory for private and academic experiments and a unique access-laboratory to study near- surface multi-physics environmental processes. This site offers operational facilities characterized by a fully connected fiber-optics network managed by a team of 3 permanent engineers and the collaboration with more than 30 research units in Europe. Initially designed for the French nuclear defence and converted in 1997 into an academic laboratory, LSBB is a hardened facility made of 3.7~km of horizontal galleries and vaults buried 500~m deep within the unsaturated zone of a carbonate platform which is a typical analogue of the currently exploited water and oil reservoirs of the Middle--East. Another major attraction of the LSBB is that it hosts a unique--in--the--world broad low-pass filter magnetic shielded zone (1500~m3 with electromagnetic noise level below 2~fT/√Hz for frequencies above 50~Hz). Thanks to such an exceptional environmental and technological context, LSBB provides one of the best european opportunities for the development of research projects related to near-surface imaging and multiscale and multiphysics coupled processes in natural porous media; magnetic field perturbations coupled to seismic wave excitations; thermo--hydromechanical and chemical fluid--rock interaction in heterogeneous carbonates; dark matter research; reliability and sensitivity to the natural radioactive environment of nano-- electronic and nano--structures. Projects interact through co--sharing of the multi--parametric and at--the-- leading--edge measurements and results, that are centralised in a dedicated internet plateform.

  9. Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 1. Biosafety Level 4 Suit Laboratory Suite Entry and Exit Procedures

    PubMed Central

    Janosko, Krisztina; Holbrook, Michael R.; Adams, Ricky; Barr, Jason; Bollinger, Laura; Newton, Je T'aime; Ntiforo, Corrie; Coe, Linda; Wada, Jiro; Pusl, Daniela; Jahrling, Peter B.; Kuhn, Jens H.; Lackemeyer, Matthew G.

    2016-01-01

    Biosafety level 4 (BSL-4) suit laboratories are specifically designed to study high-consequence pathogens for which neither infection prophylaxes nor treatment options exist. The hallmarks of these laboratories are: custom-designed airtight doors, dedicated supply and exhaust airflow systems, a negative-pressure environment, and mandatory use of positive-pressure (“space”) suits. The risk for laboratory specialists working with highly pathogenic agents is minimized through rigorous training and adherence to stringent safety protocols and standard operating procedures. Researchers perform the majority of their work in BSL-2 laboratories and switch to BSL-4 suit laboratories when work with a high-consequence pathogen is required. Collaborators and scientists considering BSL-4 projects should be aware of the challenges associated with BSL-4 research both in terms of experimental technical limitations in BSL-4 laboratory space and the increased duration of such experiments. Tasks such as entering and exiting the BSL-4 suit laboratories are considerably more complex and time-consuming compared to BSL-2 and BSL-3 laboratories. The focus of this particular article is to address basic biosafety concerns and describe the entrance and exit procedures for the BSL-4 laboratory at the NIH/NIAID Integrated Research Facility at Fort Detrick. Such procedures include checking external systems that support the BSL-4 laboratory, and inspecting and donning positive-pressure suits, entering the laboratory, moving through air pressure-resistant doors, and connecting to air-supply hoses. We will also discuss moving within and exiting the BSL-4 suit laboratories, including using the chemical shower and removing and storing positive-pressure suits. PMID:27768063

  10. Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 1. Biosafety Level 4 Suit Laboratory Suite Entry and Exit Procedures.

    PubMed

    Janosko, Krisztina; Holbrook, Michael R; Adams, Ricky; Barr, Jason; Bollinger, Laura; Newton, Je T'aime; Ntiforo, Corrie; Coe, Linda; Wada, Jiro; Pusl, Daniela; Jahrling, Peter B; Kuhn, Jens H; Lackemeyer, Matthew G

    2016-10-03

    Biosafety level 4 (BSL-4) suit laboratories are specifically designed to study high-consequence pathogens for which neither infection prophylaxes nor treatment options exist. The hallmarks of these laboratories are: custom-designed airtight doors, dedicated supply and exhaust airflow systems, a negative-pressure environment, and mandatory use of positive-pressure ("space") suits. The risk for laboratory specialists working with highly pathogenic agents is minimized through rigorous training and adherence to stringent safety protocols and standard operating procedures. Researchers perform the majority of their work in BSL-2 laboratories and switch to BSL-4 suit laboratories when work with a high-consequence pathogen is required. Collaborators and scientists considering BSL-4 projects should be aware of the challenges associated with BSL-4 research both in terms of experimental technical limitations in BSL-4 laboratory space and the increased duration of such experiments. Tasks such as entering and exiting the BSL-4 suit laboratories are considerably more complex and time-consuming compared to BSL-2 and BSL-3 laboratories. The focus of this particular article is to address basic biosafety concerns and describe the entrance and exit procedures for the BSL-4 laboratory at the NIH/NIAID Integrated Research Facility at Fort Detrick. Such procedures include checking external systems that support the BSL-4 laboratory, and inspecting and donning positive-pressure suits, entering the laboratory, moving through air pressure-resistant doors, and connecting to air-supply hoses. We will also discuss moving within and exiting the BSL-4 suit laboratories, including using the chemical shower and removing and storing positive-pressure suits.

  11. Multiweek cell culture project for use in upper-level biology laboratories.

    PubMed

    Marion, Rebecca E; Gardner, Grant E; Parks, Lisa D

    2012-06-01

    This article describes a laboratory protocol for a multiweek project piloted in a new upper-level biology laboratory (BIO 426) using cell culture techniques. Human embryonic kidney-293 cells were used, and several culture media and supplements were identified for students to design their own experiments. Treatments included amino acids, EGF, caffeine, epinephrine, heavy metals, and FBS. Students researched primary literature to determine their experimental variables, made their own solutions, and treated their cells over a period of 2 wk. Before this, a sterile technique laboratory was developed to teach students how to work with the cells and minimize contamination. Students designed their experiments, mixed their solutions, seeded their cells, and treated them with their control and experimental media. Students had the choice of manipulating a number of variables, including incubation times, exposure to treatment media, and temperature. At the end of the experiment, students observed the effects of their treatment, harvested and dyed their cells, counted relative cell numbers in control and treatment flasks, and determined the ratio of living to dead cells using a hemocytometer. At the conclusion of the experiment, students presented their findings in a poster presentation. This laboratory can be expanded or adapted to include additional cell lines and treatments. The ability to design and implement their own experiments has been shown to increase student engagement in the biology-related laboratory activities as well as develop the critical thinking skills needed for independent research.

  12. Stabilization and disposal of Argonne-West low-level mixed wastes in ceramicrete waste forms.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barber, D. B.; Singh, D.; Strain, R. V.

    1998-02-17

    The technology of room-temperature-setting phosphate ceramics or Ceramicrete{trademark} technology, developed at Argonne National Laboratory (ANL)-East is being used to treat and dispose of low-level mixed wastes through the Department of Energy complex. During the past year, Ceramicrete{trademark} technology was implemented for field application at ANL-West. Debris wastes were treated and stabilized: (a) Hg-contaminated low-level radioactive crushed light bulbs and (b) low-level radioactive Pb-lined gloves (part of the MWIR {number_sign} AW-W002 waste stream). In addition to hazardous metals, these wastes are contaminated with low-level fission products. Initially, bench-scale waste forms with simulated and actual waste streams were fabricated by acid-base reactionsmore » between mixtures of magnesium oxide powders and an acid phosphate solution, and the wastes. Size reduction of Pb-lined plastic glove waste was accomplished by cryofractionation. The Ceramicrete{trademark} process produces dense, hard ceramic waste forms. Toxicity Characteristic Leaching Procedure (TCLP) results showed excellent stabilization of both Hg and Pb in the waste forms. The principal advantage of this technology is that immobilization of contaminants is the result of both chemical stabilization and subsequent microencapsulation of the reaction products. Based on bench-scale studies, Ceramicrete{trademark} technology has been implemented in the fabrication of 5-gal waste forms at ANL-West. Approximately 35 kg of real waste has been treated. The TCLP is being conducted on the samples from the 5-gal waste forms. It is expected that because the waste forms pass the limits set by the EPAs Universal Treatment Standard, they will be sent to a radioactive-waste disposal facility.« less

  13. 12. VIEW OF (PRESUMED) OUTHOUSE SHED. DOOR HAS AN AIR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. VIEW OF (PRESUMED) OUTHOUSE SHED. DOOR HAS AN AIR FORCE INSIGNIA EMBLEM AFFIXED, 'AIR FORCE WEAPONS LABORATORY.' OTHER SIGN ON DOOR SAYS, 'BSD LIASON OFFICE.' INEL PHOTO NUMBER 65-6173, TAKEN NOVEMBER 10, 1965. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  14. Rooting depths of plants on low-level waste disposal sites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Foxx, T.S.; Tierney, G.D.; Williams, J.M.

    1984-11-01

    In 1981-1982 an extensive bibliographic study was done to reference rooting depths of native plants in the United States. The data base presently contains 1034 different rooting citations with approximately 12,000 data elements. For this report, data were analyzed for rooting depths related to species found on low-level waste (LLW) sites at Los Alamos National Laboratory. Average rooting depth and rooting frequencies were determined and related to present LLW maintenance. The data base was searched for information on rooting depths of 53 species found on LLW sites at Los Alamos National Laboratory. The study indicates 12 out of 13 grassesmore » found on LLW sites root below 91 cm. June grass (Koeleria cristata (L.) Pers.) (76 cm) was the shallowest rooting grass and side-oats grama (Bouteloua curtipendula (Michx.) Torr.) was the deepest rooting grass (396 cm). Forbs were more variable in rooting depths. Indian paintbrush (Castelleja spp.) (30 cm) was the shallowest rooting forb and alfalfa (Medicago sativa L.) was the deepest (>3900 cm). Trees and shrubs commonly rooted below 457 cm. The shallowest rooting tree was elm (Ulmus pumila L.) (127 cm) and the deepest was one-seed juniper (Juniperus monosperma (Engelm) Sarg.) (>6000 cm). Apache plume (Fallugia paradoxa (D. Don) Endl.) rooted to 140 cm, whereas fourwing saltbush (Atriplex canecens (Pursh) Nutt.) rooted to 762 cm.« less

  15. High level waste tank closure project: ALARA applications at the Idaho National Engineering and Environmental Laboratory.

    PubMed

    Aitken, Steven B; Butler, Richard; Butterworth, Steven W; Quigley, Keith D

    2005-05-01

    Bechtel BWXT Idaho, Maintenance and Operating Contractor for the Department of Energy at the Idaho National Engineering and Environmental Laboratory, has emptied, cleaned, and sampled six of the eleven 1.135 x 10(6) L high level waste underground storage tanks at the Idaho Nuclear Technology and Engineering Center, well ahead of the State of Idaho Consent Order cleaning schedule. Cleaning of a seventh tank is expected to be complete by the end of calendar year 2004. The tanks, with associated vaults, valve boxes, and distribution systems, are being closed to meet Resource Conservation and Recovery Act regulations and Department of Energy orders. The use of remotely operated equipment placed in the tanks through existing tank riser access points, sampling methods and application of as-low-as-reasonably-achievable (ALARA) principles have proven effective in keeping personnel dose low during equipment removal, tank, vault, and valve box cleaning, and sampling activities, currently at 0.03 Sv.

  16. An Alignment/Transfer Experiment with Low Socioeconomic Level Students.

    ERIC Educational Resources Information Center

    Elia, June Isaacs

    1994-01-01

    This study examined the amount of variance explained by alignment of testing to instruction among low socioeconomic level fourth graders, proposing two instructional alignment hypotheses. Results indicated that alignment had an unusually high effect. Low performing low socioeconomic level students achieved high success levels when conditions of…

  17. Radioactive Waste Management Complex low-level waste radiological performance assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maheras, S.J.; Rood, A.S.; Magnuson, S.O.

    This report documents the projected radiological dose impacts associated with the disposal of radioactive low-level waste at the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory. This radiological performance assessment was conducted to evaluate compliance with applicable radiological criteria of the US Department of Energy and the US Environmental Protection Agency for protection of the public and the environment. The calculations involved modeling the transport of radionuclides from buried waste, to surface soil and subsurface media, and eventually to members of the public via air, groundwater, and food chain pathways. Projections of doses were made for both offsitemore » receptors and individuals inadvertently intruding onto the site after closure. In addition, uncertainty and sensitivity analyses were performed. The results of the analyses indicate compliance with established radiological criteria and provide reasonable assurance that public health and safety will be protected.« less

  18. Laboratory safety aspects of SARS at Biosafety Level 2.

    PubMed

    Barkham, T M S

    2004-03-01

    The severe acute respiratory syndrome (SARS)-associated coronavirus causes severe disease, is transmissible to the community and there is no effective prophylaxis or treatment--perhaps fulfilling the criteria for biohazard group 3 or 4. The recommendation to use Biosafety Level (BSL)3 practices within a BSL2 environment appears to have been a practical decision based on available resources; most diagnostic laboratories operate at BSL2. Safety is achieved with controls in administration, engineering and personal protective equipment/behaviour. At the heart of every safety policy is a risk assessment based on the exact manipulations employed. Excessive administrative and engineering controls are less important than the training and personal attitudes, abilities and understanding of the staff. The SARS outbreak focused our attention on the safety aspects of common mundane tasks, such as decapping blood tubes. Laboratories often claim they follow certain practices but casual observation does not always support these claims. Guidelines differed and created uncertainty. This was stressful for laboratory staff held accountable for their implementation. Attempts to categorise risks and their management into neatly wrapped parcels are attractive, but closer inspection reveals a subjective element that allows doubt to creep in with varying interpretations of the literature. Staff most at risk were those handling respiratory samples. Staff receiving samples via pneumatic tubes had least control over their exposure and were potentially exposed to aerosols from leaking samples. Risk assessment remains a balance between cost and benefit.

  19. The Relationship between Serum Zonulin Level and Clinical and Laboratory Parameters of Childhood Obesity.

    PubMed

    Küme, Tuncay; Acar, Sezer; Tuhan, Hale; Çatlı, Gönül; Anık, Ahmet; Gürsoy Çalan, Özlem; Böber, Ece; Abacı, Ayhan

    2017-03-01

    To investigate the relationship between zonulin levels and clinical and laboratory parameters of childhood obesity. The study included obese children with a body mass index (BMI) >95 th percentile and healthy children who were of similar age and gender distribution. Clinical (BMI, waist circumferences, mid-arm circumference, triceps skinfold, percentage of body fat, systolic blood pressure, diastolic blood pressure) and biochemical (glucose, insulin, lipid levels, thyroid function tests, cortisol, zonulin and leptin levels) parameters were measured. A total of 43 obese subjects (23 males, mean age: 11.1±3.1 years) and 37 healthy subjects (18 males, mean age: 11.5±3.5 years) were included in this study. Obese children had significantly higher insulin, homeostasis model assessment of insulin resistance, triglyceride, total cholesterol, low-density lipoprotein cholesterol, high-density lipoprotein cholesterol (HDL-C), zonulin and leptin levels than healthy children (p<0.05), while glucose levels were not different (p>0.05). Comparison of the obese children with and without insulin resistance showed no statistically significant differences for zonulin levels (p>0.05). Zonulin levels were found to negatively correlate with HDL-C and positively correlate with leptin levels, after adjusting for age and BMI. To the best of our knowledge, this is the first study investigating the relationship between circulating zonulin level (as a marker of intestinal permeability) and insulin resistance and leptin (as markers of metabolic disturbances associated with obesity) in childhood obesity. The results showed that zonulin was significantly higher in obese children when compared to healthy children, a finding indicating a potential role of zonulin in the etiopathogenesis of obesity and related disturbances.

  20. Ambient and laboratory evaluation of a low-cost particulate matter sensor.

    PubMed

    Kelly, K E; Whitaker, J; Petty, A; Widmer, C; Dybwad, A; Sleeth, D; Martin, R; Butterfield, A

    2017-02-01

    Low-cost, light-scattering-based particulate matter (PM) sensors are becoming more widely available and are being increasingly deployed in ambient and indoor environments because of their low cost and ability to provide high spatial and temporal resolution PM information. Researchers have begun to evaluate some of these sensors under laboratory and environmental conditions. In this study, a low-cost, particulate matter sensor (Plantower PMS 1003/3003) used by a community air-quality network is evaluated in a controlled wind-tunnel environment and in the ambient environment during several winter-time, cold-pool events that are associated with high ambient levels of PM. In the wind-tunnel, the PMS sensor performance is compared to two research-grade, light-scattering instruments, and in the ambient tests, the sensor performance is compared to two federal equivalent (one tapered element oscillating microbalance and one beta attenuation monitor) and gravimetric federal reference methods (FEMs/FRMs) as well as one research-grade instrument (GRIMM). The PMS sensor response correlates well with research-grade instruments in the wind-tunnel tests, and its response is linear over the concentration range tested (200-850 μg/m 3 ). In the ambient tests, this PM sensor correlates better with gravimetric methods than previous studies with correlation coefficients of 0.88. However additional measurements under a variety of ambient conditions are needed. Although the PMS sensor correlated as well as the research-grade instrument to the FRM/FEMs in ambient conditions, its response varies with particle properties to a much greater degree than the research-grade instrument. In addition, the PMS sensors overestimate ambient PM concentrations and begin to exhibit a non-linear response when PM 2.5 concentrations exceed 40 μg/m 3 . These results have important implications for communicating results from low-cost sensor networks, and they highlight the importance of using an

  1. Low-level awareness accompanies "unconscious" high-level processing during continuous flash suppression.

    PubMed

    Gelbard-Sagiv, Hagar; Faivre, Nathan; Mudrik, Liad; Koch, Christof

    2016-01-01

    The scope and limits of unconscious processing are a matter of ongoing debate. Lately, continuous flash suppression (CFS), a technique for suppressing visual stimuli, has been widely used to demonstrate surprisingly high-level processing of invisible stimuli. Yet, recent studies showed that CFS might actually allow low-level features of the stimulus to escape suppression and be consciously perceived. The influence of such low-level awareness on high-level processing might easily go unnoticed, as studies usually only probe the visibility of the feature of interest, and not that of lower-level features. For instance, face identity is held to be processed unconsciously since subjects who fail to judge the identity of suppressed faces still show identity priming effects. Here we challenge these results, showing that such high-level priming effects are indeed induced by faces whose identity is invisible, but critically, only when a lower-level feature, such as color or location, is visible. No evidence for identity processing was found when subjects had no conscious access to any feature of the suppressed face. These results suggest that high-level processing of an image might be enabled by-or co-occur with-conscious access to some of its low-level features, even when these features are not relevant to the processed dimension. Accordingly, they call for further investigation of lower-level awareness during CFS, and reevaluation of other unconscious high-level processing findings.

  2. 10 CFR 71.14 - Exemption for low-level materials.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 2 2011-01-01 2011-01-01 false Exemption for low-level materials. 71.14 Section 71.14... Exemptions § 71.14 Exemption for low-level materials. (a) A licensee is exempt from all the requirements of this part with respect to shipment or carriage of the following low-level materials: (1) Natural...

  3. 10 CFR 71.14 - Exemption for low-level materials.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Exemption for low-level materials. 71.14 Section 71.14... Exemptions § 71.14 Exemption for low-level materials. (a) A licensee is exempt from all the requirements of this part with respect to shipment or carriage of the following low-level materials: (1) Natural...

  4. Low-level information and high-level perception: the case of speech in noise.

    PubMed

    Nahum, Mor; Nelken, Israel; Ahissar, Merav

    2008-05-20

    Auditory information is processed in a fine-to-crude hierarchical scheme, from low-level acoustic information to high-level abstract representations, such as phonological labels. We now ask whether fine acoustic information, which is not retained at high levels, can still be used to extract speech from noise. Previous theories suggested either full availability of low-level information or availability that is limited by task difficulty. We propose a third alternative, based on the Reverse Hierarchy Theory (RHT), originally derived to describe the relations between the processing hierarchy and visual perception. RHT asserts that only the higher levels of the hierarchy are immediately available for perception. Direct access to low-level information requires specific conditions, and can be achieved only at the cost of concurrent comprehension. We tested the predictions of these three views in a series of experiments in which we measured the benefits from utilizing low-level binaural information for speech perception, and compared it to that predicted from a model of the early auditory system. Only auditory RHT could account for the full pattern of the results, suggesting that similar defaults and tradeoffs underlie the relations between hierarchical processing and perception in the visual and auditory modalities.

  5. Coupling Legacy and Contemporary Deterministic Codes to Goldsim for Probabilistic Assessments of Potential Low-Level Waste Repository Sites

    NASA Astrophysics Data System (ADS)

    Mattie, P. D.; Knowlton, R. G.; Arnold, B. W.; Tien, N.; Kuo, M.

    2006-12-01

    Sandia National Laboratories (Sandia), a U.S. Department of Energy National Laboratory, has over 30 years experience in radioactive waste disposal and is providing assistance internationally in a number of areas relevant to the safety assessment of radioactive waste disposal systems. International technology transfer efforts are often hampered by small budgets, time schedule constraints, and a lack of experienced personnel in countries with small radioactive waste disposal programs. In an effort to surmount these difficulties, Sandia has developed a system that utilizes a combination of commercially available codes and existing legacy codes for probabilistic safety assessment modeling that facilitates the technology transfer and maximizes limited available funding. Numerous codes developed and endorsed by the United States Nuclear Regulatory Commission and codes developed and maintained by United States Department of Energy are generally available to foreign countries after addressing import/export control and copyright requirements. From a programmatic view, it is easier to utilize existing codes than to develop new codes. From an economic perspective, it is not possible for most countries with small radioactive waste disposal programs to maintain complex software, which meets the rigors of both domestic regulatory requirements and international peer review. Therefore, re-vitalization of deterministic legacy codes, as well as an adaptation of contemporary deterministic codes, provides a creditable and solid computational platform for constructing probabilistic safety assessment models. External model linkage capabilities in Goldsim and the techniques applied to facilitate this process will be presented using example applications, including Breach, Leach, and Transport-Multiple Species (BLT-MS), a U.S. NRC sponsored code simulating release and transport of contaminants from a subsurface low-level waste disposal facility used in a cooperative technology transfer

  6. A Framework for Translating a High Level Security Policy into Low Level Security Mechanisms

    NASA Astrophysics Data System (ADS)

    Hassan, Ahmed A.; Bahgat, Waleed M.

    2010-01-01

    Security policies have different components; firewall, active directory, and IDS are some examples of these components. Enforcement of network security policies to low level security mechanisms faces some essential difficulties. Consistency, verification, and maintenance are the major ones of these difficulties. One approach to overcome these difficulties is to automate the process of translation of high level security policy into low level security mechanisms. This paper introduces a framework of an automation process that translates a high level security policy into low level security mechanisms. The framework is described in terms of three phases; in the first phase all network assets are categorized according to their roles in the network security and relations between them are identified to constitute the network security model. This proposed model is based on organization based access control (OrBAC). However, the proposed model extend the OrBAC model to include not only access control policy but also some other administrative security policies like auditing policy. Besides, the proposed model enables matching of each rule of the high level security policy with the corresponding ones of the low level security policy. Through the second phase of the proposed framework, the high level security policy is mapped into the network security model. The second phase could be considered as a translation of the high level security policy into an intermediate model level. Finally, the intermediate model level is translated automatically into low level security mechanism. The paper illustrates the applicability of proposed approach through an application example.

  7. APNEA/WIT system nondestructive assay capability evaluation plan for select accessibly stored INEL RWMC waste forms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Becker, G.K.

    1997-01-01

    Bio-Imaging Research Inc. (BIR) and Lockheed Martin Speciality Components (LMSC) are engaged in a Program Research and Development Agreement and a Rapid Commercialization Initiative with the Department of Energy, EM-50. The agreement required BIR and LMSC to develop a data interpretation method that merges nondestructive assay and nondestructive examination (NDA/NDE) data and information sufficient to establish compliance with applicable National TRU Program (Program) waste characterization requirements and associated quality assurance performance criteria. This effort required an objective demonstration of the BIR and LMSC waste characterization systems in their standalone and integrated configurations. The goal of the test plan is tomore » provide a mechanism from which evidence can be derived to substantiate nondestructive assay capability and utility statement for the BIT and LMSC systems. The plan must provide for the acquisition, compilation, and reporting of performance data thereby allowing external independent agencies a basis for an objective evaluation of the standalone BIR and LMSC measurement systems, WIT and APNEA respectively, as well as an expected performance resulting from appropriate integration of the two systems. The evaluation is to be structured such that a statement regarding select INEL RWMC waste forms can be made in terms of compliance with applicable Program requirements and criteria.« less

  8. The Role of Low-Level Laser in Periodontal Surgeries

    PubMed Central

    Sobouti, Farhad; Khatami, Maziar; Heydari, Mohaddase; Barati, Maryam

    2015-01-01

    Treatment protocols with low-level Laser (also called ‘soft laser therapy) have been used in health care systems for more than three decades. Bearing in mind the suitable sub-cellular absorption and the cellular-vascular impacts, low-level laser may be a treatment of choice for soft tissues. Low-level lasers have played crucial and colorful roles in performing periodontal surgeries. Their anti-inflammatory and painless effects have been variously reported in in-vitro studies. In this present review article, searches have been made in Pub Med, Google Scholar, and Science Direct, focusing on the studies which included low-level lasers, flap-periodontal surgeries, gingivectomy, and periodontal graft. The present study has sought to review the cellular impacts of low-level lasers and its role on reducing pain and inflammation following soft tissue surgical treatments. PMID:25987968

  9. The molecular basis of low activity levels of coagulation factor VII: a Brazilian cohort.

    PubMed

    Rabelo, F Y; Jardim, L L; Landau, M B; Gadelha, T; Corrêa, M F B; Pereira, I F M; Rezende, S M

    2015-09-01

    Inherited factor VII (FVII) deficiency is the most common among the rare bleeding disorders. It is transmitted as an autosomal recessive inheritance, due to mutations in the FVII gene (F7). Molecular studies of FVII deficiency are rare in non-Caucasian populations. The aim of the study was to evaluate the molecular basis behind low levels of FVII activity (FVII:C) levels in a cohort of Brazilian patients. A total of 34 patients with low FVII levels were clinically evaluated and submitted to laboratory tests, among these, prothrombin time and FVII:C, with different thromboplastins. All exons and intron/exon boundaries of F7 were amplified and sequenced. A total of 14 genetic alterations were identified, of which six were described previously, c.1091G>A, c.1151C>T, c.-323_-313insCCTATATCCT, c.285G>A, c.525C>T, c.1238G>A and eight (54.0%) and eight were new, c.128G>A, c.252C>T, c.348G>A, c.417G>A, c.426G>A, c.745_747delGTG, c.843G>A and c.805+52C>T. In addition to the mutation c.1091G>A, known as FVII Padua, the mutation c.1151C>T also presented discrepant FVII:C levels when tested with human and rabbit brain thromboplastin. There was no association between phenotype and genotype. Most of the identified genetic alterations found were polymorphisms. Low levels of FVII:C in this population were mostly related to polymorphisms in F7 and associated with a mild clinical phenotype. Mutation c.1151C>T was associated with discrepant levels of FVII:C using different thromboplastins, such as reported with FVII Padua. © 2015 John Wiley & Sons Ltd.

  10. Low-level light therapy for zymosan-induced arthritis in rats

    NASA Astrophysics Data System (ADS)

    Castano, Ana P.; Dai, Tianhong; Demidova-Rice, Tatiana N.; Salomatina, Elena V.; Yaroslavsky, Anna N.; Yaroslavsky, Ilya; Cohen, Richard; Apruzzese, William A.; Smotrich, Michael H.; Hamblin, Michael R.

    2007-02-01

    It has been known for many years that low level laser (or light) therapy (LLLT) can ameliorate the pain, swelling and inflammation associated with various forms of arthritis. Light is absorbed by mitochondrial chromophores leading to an increase in ATP, reactive oxygen species and/or cyclic AMP production and consequent gene transcription via activation of transcription factors. However, despite many reports about the positive effects of LLLT in medicine, its use remains controversial. Our laboratory has developed animal models designed to objectively quantify response to LLLT and compare different light delivery regimens. In the arthritis model we inject zymosan into rat knee joints to induce inflammatory arthritis. We have compared illumination regimens consisting of a high and low fluence (3 J/cm2 and 30 J/cm2), delivered at a high and low irradiance (5 mW/cm2 and 50 mW/cm2) using 810-nm laser light daily for 5 days, with the effect of conventional corticosteroid (dexamethasone) therapy. Results indicated that illumination with 810-nm laser is highly effective (almost as good as dexamethasone) at reducing swelling and that longer illumination time was more important in determining effectiveness than either total fluence delivered or irradiance. Experiments carried out using 810-nm LLLT on excisional wound healing in mice also confirmed the importance of longer illumination times. These data will be of value in designing clinical trials of LLLT.

  11. Gross Alpha Beta Radioactivity in Air Filters Measured by Ultra Low Level α/β Counter

    NASA Astrophysics Data System (ADS)

    Cfarku, Florinda; Bylyku, Elida; Deda, Antoneta; Dhoqina, Polikron; Bakiu, Erjona; Perpunja, Flamur

    2010-01-01

    Study of radioactivity in air as very important for life is done regularly using different methods in every country. As a result of nuclear reactors, atomic centrals, institutions and laboratories, which use the radioactivity substances in open or closed sources, there are a lot radioactive wastes. Mixing of these wastes after treatment with rivers and lakes waters makes very important control of radioactivity. At the other side nuclear and radiological accidents are another source of the contamination of air and water. Due to their radio toxicity, especially those of Sr90, Pu239, etc. a contamination hazard for human begins exist even at low concentration levels. Measurements of radioactivity in air have been performed in many parts of the world mostly for assessment of the doses and risk resulting from consuming air. In this study we present the results of international comparison organized by IAEA Vienna, Austria for the air filters spiked with unknown Alpha and Beta Activity. For the calibration of system we used the same filters spiked: a) with Pu-239 as alpha source; b) Sr-90 as beta source and also the blank filter. The measurements of air filter samples after calibration of the system are done with Ultra Low Level α/β Counter (MPC 9604) Protean Instrument Corporation. The high sensitivity of the system for the determination of the Gross Alpha and Beta activity makes sure detection of low values activity of air filters. Our laboratory results are: Aα = (0.19±0.01) Bq/filter and Aα (IAEA) = (0.17±0.009) Bq/filter; Aβ = (0.33±0.009) Bq/filter and Aβ (IAEA) = (0.29±0.01) Bq/filter. As it seems our results are in good agreement with reference values given by IAEA (International Atomic Energy Agency).

  12. Laboratory Testing of Electro-Osmotic Pulse Technology to Reduce and Maintain Low Moisture Content in Concrete

    DTIC Science & Technology

    2009-02-01

    technology minimizes harmful effects to concrete and rebar and prevents over drying, pore blocking and electrode polarization. Principles of EOP...LABORATORY TESTING OF ELECTRO-OSMOTIC PULSE TECHNOLOGY TO REDUCE AND MAINTAIN LOW MOISTURE CONTENT IN CONCRETE Orange S. Marshall, Vincent F...Laboratory 2009 Army Corrosion Summit Clearwater Beach, FL 6 January 2009 Report Documentation Page Form ApprovedOMB No. 0704-0188 Public reporting

  13. Low plasma vitamin D levels and muscle-related adverse effects in statin users.

    PubMed

    Eisen, Alon; Lev, Eli; Iakobishvilli, Zaza; Porter, Avital; Brosh, David; Hasdai, David; Mager, Aviv

    2014-01-01

    Treatment with HMG-CoA reductase inhibitors (statins) is often complicated by muscle-related adverse effects (MAEs). Studies of the association between low plasma vitamin D levels and MAEs have yielded conflicting results. To determine if low plasma vitamin D level is a risk factorfor MAEs in statin users. Plasma levels of 25(OH) vitamin D were measured as part of the routine evaluation of unselected statin-treated patients attending the coronary and lipid clinics at our hospital during the period 2007-2010. Medical data on muscle complaints and statin use were retrieved from the medical files. Creatine kinase (CK) levels were derived from the hospital laboratory database. The sample included 272 patients (141 men) aged 33-89 years. Mean vitamin D level was 48.04 nmol/L. Levels were higher in men (51.0 +/- 20.5 versus 44.7 +/- 18.9 nmol/L, P = 0.001) and were unaffected by age. MAEs were observed in 106 patients (39%): myalgia in 95 (35%) and CK elevation in 20 (7%); 9 patients (3%) had both. There was no difference in plasma vitamin D levels between patients with and without myalgia (46.3 +/- 17.7 versus 48.9 +/- 21.0 nmol/L, P = 0.31), with and without CK elevation (50.2 +/- 14.6 versus 47.8 +/- 20.3 nmol/L, P = 0.60), or with or without any MAE (50.4 +/- 15.0 versus 47.8 +/- 10.2 nmol/L, P = 0.27). These findings were consistent when analyzed by patient gender and presence/absence of coronary artery disease, and when using a lower vitamin D cutoff (< 25 nmol/L). There is apparently no relationship between plasma vitamin D level and risk of MAEs in statin users.

  14. Hydrology of the solid waste burial ground as related to potential migration of radionuclides, Idaho National Engineering Laboratory

    USGS Publications Warehouse

    Barraclough, Jack T.; Robertson, J.B.; Janzer, V.J.; Saindon, L.G.

    1976-01-01

    A study was made (1970-1974) to evaluate the geohydrologic and geochemical controls on subsurface migration of radionuclides from pits and trenches in the Idaho National Engineering Laboratory (INEL) solid waste burial ground and to determine the existence and extent of radionuclide migration from the burial ground. A total of about 1,700 sediment, rock, and water samples were collected from 10 observation wells drilled in and near the burial ground of Idaho National Engineering Laboratory, formerly the National Reactor Testing Station (NRTS). Within the burial ground area, the subsurface rocks are composed principally of basalt. Wind- and water-deposited sediments occur at the surface and in beds between the thicker basalt zones. Two principal sediment beds occur at about 110 feet and 240 feet below the land surface. The average thickness of the surficial sedimentary layer is about 15 feet while that of the two principal subsurface layers is 13 and 14 feet, respectively. The water table in the aquifer beneath the burial ground is at a depth of about 580 feet. Fission, activation, and transuranic elements were detected in some of the samples from the 110- and 240-foot sedimentary layers. (Woodard-USGS)

  15. Comparison of the effects of filtration and preservation methods on analyses for strontium-90 in ground water

    USGS Publications Warehouse

    Knobel, L.L.; DeWayne, Cecil L.; Wegner, S.J.; Moore, L.L.

    1992-01-01

    From 1952 to 1988, about 140 curies of strontium-90 were discharged in liquid waste to disposal ponds and wells at the INEL (Idaho National Engineering Laboratory). Water from four wells was sampled as part of the U.S. Geological Survey's quality-assurance program to evaluate the effects of filtration and preservation methods on strontium-90 concentrations in ground water at the INEL. Water from each well was filtered through eithera 0.45- or a 0.1-micrometer membrane filter; unfiltered samples also were collected. Two sets of filtered and two sets of unfiltered water samples were collected at each well. One of the two sets of water samples was field acidified. Strontium-90 concentrations ranged from below the reporting level to 52 ?? 4 picocuries per liter. Descriptive statistics were used to determine reproducibility of the analytical results for strontium-90 concentrations in water from each well. Comparisons were made with unfiltered, acidified samples at each well. Analytical results for strontium-90 concentrations in water from well 88 were not in statistical agreement between the unfiltered, acidified sample and the filtered (0.45 micrometer), acidified sample. The strontium-90 concentration for water from well 88 was less than the reporting level. For water from wells with strontium-90 concentrations at or above the reporting level, 94 percent or more of the strontium-90 is in true solution or in colloidal particles smaller than 0.1 micrometer. These results suggest that changes in filtration and preservation methods used for sample collection do not significantly affect reproducibility of strontium-90 analyses in ground water at the INEL.

  16. Comparison of the effects of filtration and preservation methods on analyses for strontium-90 in ground water.

    PubMed

    Knobel, L L; Cecil, L D; Wegner, S J; Moore, L L

    1992-01-01

    From 1952 to 1988, about 140 curies of strontium-90 were discharged in liquid waste to disposal ponds and wells at the INEL (Idaho National Engineering Laboratory). Water from four wells was sampled as part of the U.S. Geological Survey's quality-assurance program to evaluate the effects of filtration and preservation methods on strontium-90 concentrations in ground water at the INEL. Water from each well was filtered through either a 0.45- or a 0.1-micrometer membrane filter; unfiltered samples also were collected. Two sets of filtered and two sets of unfiltered water samples were collected at each well. One of the two sets of water samples was field acidified.Strontium-90 concentrations ranged from below the reporting level to 52±4 picocuries per liter. Descriptive statistics were used to determine reproducibility of the analytical results for strontium-90 concentrations in water from each well. Comparisons were made with unfiltered, acidified samples at each well. Analytical results for strontium-90 concentrations in water from well 88 were not in statistical agreement between the unfiltered, acidified sample and the filtered (0.45 micrometer), acidified sample. The strontium-90 concentration for water from well 88 was less than the reporting level.For water from wells with strontium-90 concentrations at or above the reporting level, 94 percent or more of the strontium-90 is in true solution or in colloidal particles smaller than 0.1 micrometer. These results suggest that changes in filtration and preservation methods used for sample collection do not significantly affect reproducibility of strontium-90 analyses in ground water at the INEL.

  17. 19. INTERIOR VIEW INSIDE BUNKER SHOWING NITROGEN TANKS, 'MOBILE AIR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. INTERIOR VIEW INSIDE BUNKER SHOWING NITROGEN TANKS, 'MOBILE AIR MONITOR' EQUIPMENT, MAN. INEL PHOTO NUMBER 65-6183, TAKEN NOVEMBER 10, 1965. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  18. Laboratory study of low-β forces in arched, line-tied magnetic flux ropes

    NASA Astrophysics Data System (ADS)

    Myers, C. E.; Yamada, M.; Ji, H.; Yoo, J.; Jara-Almonte, J.; Fox, W.

    2016-11-01

    The loss-of-equilibrium is a solar eruption mechanism whereby a sudden breakdown of the magnetohydrodynamic force balance in the Sun's corona ejects a massive burst of particles and energy into the heliosphere. Predicting a loss-of-equilibrium, which has more recently been formulated as the torus instability, relies on a detailed understanding of the various forces that hold the pre-eruption magnetic flux rope in equilibrium. Traditionally, idealized analytical force expressions are used to derive simplified eruption criteria that can be compared to solar observations and modeling. What is missing, however, is a validation that these idealized analytical force expressions can be applied to the line-tied, low-aspect-ratio conditions of the corona. In this paper, we address this shortcoming by using a laboratory experiment to study the forces that act on long-lived, arched, line-tied magnetic flux ropes. Three key force terms are evaluated over a wide range of experimental conditions: (1) the upward hoop force; (2) the downward strapping force; and (3) the downward toroidal field tension force. First, the laboratory force measurements show that, on average, the three aforementioned force terms cancel to produce a balanced line-tied equilibrium. This finding validates the laboratory force measurement techniques developed here, which were recently used to identify a dynamic toroidal field tension force that can prevent flux rope eruptions [Myers et al., Nature 528, 526 (2015)]. The verification of magnetic force balance also confirms the low-β assumption that the plasma thermal pressure is negligible in these experiments. Next, the measured force terms are directly compared to corresponding analytical expressions. While the measured and analytical forces are found to be well correlated, the low-aspect-ratio, line-tied conditions in the experiment are found to both reduce the measured hoop force and increase the measured tension force with respect to analytical

  19. Laboratory study of low- β forces in arched, line-tied magnetic flux ropes

    DOE PAGES

    Myers, C. E.; Yamada, M.; Ji, H.; ...

    2016-11-04

    Here, the loss-of-equilibrium is a solar eruption mechanism whereby a sudden breakdown of the magnetohydrodynamic force balance in the Sun's corona ejects a massive burst of particles and energy into the heliosphere. Predicting a loss-of-equilibrium, which has more recently been formulated as the torus instability, relies on a detailed understanding of the various forces that hold the pre-eruption magnetic flux rope in equilibrium. Traditionally, idealized analytical force expressions are used to derive simplified eruption criteria that can be compared to solar observations and modeling. What is missing, however, is a validation that these idealized analytical force expressions can be appliedmore » to the line-tied, low-aspect-ratio conditions of the corona. In this paper, we address this shortcoming by using a laboratory experiment to study the forces that act on long-lived, arched, line-tied magnetic flux ropes. Three key force terms are evaluated over a wide range of experimental conditions: (1) the upward hoop force; (2) the downward strapping force; and (3) the downward toroidal field tension force. First, the laboratory force measurements show that, on average, the three aforementioned force terms cancel to produce a balanced line-tied equilibrium. This finding validates the laboratory force measurement techniques developed here, which were recently used to identify a dynamic toroidal field tension force that can prevent flux rope eruption. The verification of magnetic force balance also confirms the low-beta assumption that the plasma thermal pressure is negligible in these experiments. Next, the measured force terms are directly compared to corresponding analytical expressions. While the measured and analytical forces are found to be well correlated, the low-aspect-ratio, line-tied conditions in the experiment are found to both reduce the measured hoop force and increase the measured tension force with respect to analytical expectations. These two co

  20. Laboratory study of low- β forces in arched, line-tied magnetic flux ropes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Myers, C. E.; Yamada, M.; Ji, H.

    Here, the loss-of-equilibrium is a solar eruption mechanism whereby a sudden breakdown of the magnetohydrodynamic force balance in the Sun's corona ejects a massive burst of particles and energy into the heliosphere. Predicting a loss-of-equilibrium, which has more recently been formulated as the torus instability, relies on a detailed understanding of the various forces that hold the pre-eruption magnetic flux rope in equilibrium. Traditionally, idealized analytical force expressions are used to derive simplified eruption criteria that can be compared to solar observations and modeling. What is missing, however, is a validation that these idealized analytical force expressions can be appliedmore » to the line-tied, low-aspect-ratio conditions of the corona. In this paper, we address this shortcoming by using a laboratory experiment to study the forces that act on long-lived, arched, line-tied magnetic flux ropes. Three key force terms are evaluated over a wide range of experimental conditions: (1) the upward hoop force; (2) the downward strapping force; and (3) the downward toroidal field tension force. First, the laboratory force measurements show that, on average, the three aforementioned force terms cancel to produce a balanced line-tied equilibrium. This finding validates the laboratory force measurement techniques developed here, which were recently used to identify a dynamic toroidal field tension force that can prevent flux rope eruption. The verification of magnetic force balance also confirms the low-beta assumption that the plasma thermal pressure is negligible in these experiments. Next, the measured force terms are directly compared to corresponding analytical expressions. While the measured and analytical forces are found to be well correlated, the low-aspect-ratio, line-tied conditions in the experiment are found to both reduce the measured hoop force and increase the measured tension force with respect to analytical expectations. These two co

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rope, S.K.; Pearson, L.C.

    Two measurement techniques were employed to evaluate the feasibility of using lichens as in situ biomonitors of atmospheric pollution in a semiarid climate - trace element analysis and electrolyte leakage from cells. Trace element concentrations were generally higher in Lecanora melanophthalma (ram.) Ram. tissues than previously measured in sagebrush (Artemisia tridentata) and perennial grasses from the same locations, but lower than in soil. Lichens from an urban area (Idaho Falls) had statistically higher concentrations of ten elements, particularly lead and zinc, than those from the Idaho National Engineering Laboratory (INEL) and Craters of the Moon National Monument. Levels of fluoride,more » nickel, and seven other elements were high at the INEL relative to the other sites. Thalli collected downwind from the Idaho Chemical Processing Plant (ICPP) at the INEL were significantly higher in boron and lead content than those collected at crosswind locations: levels of eleven elements were significantly higher in lichens collected at 5 or 10 km from the ICPP than in those collected at 2 km. Electrolyte leakage was greatest from thalli collected in the nighttime downwind direction from the ICPP, even though daytime winds, which blow in the opposite direction, are more frequent, suggesting that in a semiarid climate, injury from atmospheric SO{sub 2} and NO{sub x} pollution in lichen tissues is greatest when the thalli are moist from morning dew or other sources. These results demonstrate that some lichen species, especially Lecanora melanophthalma, have potential for biomonitoring of atmospheric pollutants in the semiarid regions of the Intermountain West.« less

  2. Mixed and low-level waste treatment project: Appendix C, Health and safety criteria for the mixed and low-level waste treatment facility at the Idaho National Engineering Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neupauer, R.M.; Thurmond, S.M.

    This report contains health and safety information relating to the chemicals that have been identified in the mixed waste streams at the Waste Treatment Facility at the Idaho National Engineering Laboratory. Information is summarized in two summary sections--one for health considerations and one for safety considerations. Detailed health and safety information is presented in material safety data sheets (MSDSs) for each chemical.

  3. Laboratory meter-scale seismic monitoring of varying water levels in granular media

    NASA Astrophysics Data System (ADS)

    Pasquet, S.; Bodet, L.; Bergamo, P.; Guérin, R.; Martin, R.; Mourgues, R.; Tournat, V.

    2016-12-01

    Laboratory physical modelling and non-contacting ultrasonic techniques are frequently proposed to tackle theoretical and methodological issues related to geophysical prospecting. Following recent developments illustrating the ability of seismic methods to image spatial and/or temporal variations of water content in the vadose zone, we developed laboratory experiments aimed at testing the sensitivity of seismic measurements (i.e., pressure-wave travel times and surface-wave phase velocities) to water saturation variations. Ultrasonic techniques were used to simulate typical seismic acquisitions on small-scale controlled granular media presenting different water levels. Travel times and phase velocity measurements obtained at the dry state were validated with both theoretical models and numerical simulations and serve as reference datasets. The increasing water level clearly affects the recorded wave field in both its phase and amplitude, but the collected data cannot yet be inverted in the absence of a comprehensive theoretical model for such partially saturated and unconsolidated granular media. The differences in travel time and phase velocity observed between the dry and wet models show patterns that are interestingly coincident with the observed water level and depth of the capillary fringe, thus offering attractive perspectives for studying soil water content variations in the field.

  4. Derived concentration guideline levels for Argonne National Laboratory's building 310 area.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kamboj, S., Dr.; Yu, C ., Dr.

    2011-08-12

    The derived concentration guideline level (DCGL) is the allowable residual radionuclide concentration that can remain in soil after remediation of the site without radiological restrictions on the use of the site. It is sometimes called the single radionuclide soil guideline or the soil cleanup criteria. This report documents the methodology, scenarios, and parameters used in the analysis to support establishing radionuclide DCGLs for Argonne National Laboratory's Building 310 area.

  5. An investigation of energy balances in palladium cathode electrolysis experiments

    NASA Astrophysics Data System (ADS)

    Longhurst, G. R.; Dolan, T. J.; Henriksen, G. L.

    1990-09-01

    A series of experiments was performed at the Idaho National Engineering Laboratory (INEL) to investigate mechanisms that may contribute to energy flows in electrolysis cells like those of Fleischmann and Pons. Ordinary water (H2O), heavy water (D2O), and a mixture of the two were used in the INEL experiments. Cathodes used include a 51-μm Pd foil and 1-mm diameter extruded wire Pd rods in straight and coiled configurations. Energy balances in these experiments revealed no significant net gain or net loss of energy. Cell overpotential curves were fit well with a Tafel equation, with parameters dependent on electrode configuration, electrolyte composition, and temperature. Water evaporation and interactions of hydrogen isotopes with the Pd cathode were evaluated and found not to be significant to energy balances. No ionizing radiation, tritium production, or other evidence of fusion reactions was observed in the INEL experiments.

  6. Serum neuron-specific enolase levels from the same patients differ between laboratories: assessment of a prospective post-cardiac arrest cohort.

    PubMed

    Mlynash, Michael; Buckwalter, Marion S; Okada, Ami; Caulfield, Anna Finley; Venkatasubramanian, Chitra; Eyngorn, Irina; Verbeek, Marcel M; Wijman, Christine A C

    2013-10-01

    In comatose post-cardiac arrest patients, a serum neuron-specific enolase (NSE) level of >33 μg/L within 72 h was identified as a reliable marker for poor outcome in a large Dutch study (PROPAC), and this level was subsequently adopted in an American Academy of Neurology practice parameter. Later studies reported that NSE >33 μg/L is not a reliable predictor of poor prognosis. To test whether different clinical laboratories contribute to this variability, we compared NSE levels from the laboratory used in the PROPAC study (DLM-Nijmegen) with those of our hospital's laboratory (ARUP) using paired blood samples. We prospectively enrolled cardiac arrest patients who remained comatose after resuscitation. During the first 3 days, paired blood samples for serum NSE were drawn at a median of 10 min apart. After standard preparation for each lab, one sample was sent to ARUP laboratories and the other to DLM-Nijmegen. Fifty-four paired serum samples from 33 patients were included. Although the serum NSE measurements correlated well between laboratories (R = 0.91), the results from ARUP were approximately 30% lower than those from DLM-Nijmegen. Therapeutic hypothermia did not affect this relationship. Two patients had favorable outcomes after hypothermia despite NSE levels measured by DLM-Nijmegen as >33 μg/L. Absolute serum NSE levels of comatose cardiac arrest patients differ between laboratories. Any specific absolute cut-off levels proposed to prognosticate poor outcome should not be used without detailed data on how neurologic outcomes correspond to a particular laboratory's method, and even then only in conjunction with other prognostic variables.

  7. National Water Quality Laboratory - A Profile

    USGS Publications Warehouse

    Raese, Jon W.

    2001-01-01

    The U.S. Geological Survey (USGS) National Water Quality Laboratory (NWQL) is a full-service laboratory that specializes in environmental analytical chemistry. The NWQL's primary mission is to support USGS programs requiring environmental analyses that provide consistent methodology for national assessment and trends analysis. The NWQL provides the following: high-quality chemical data; consistent, published, state-of-the-art methodology; extremely low-detection levels; high-volume capability; biological unit for identifying benthic invertebrates; quality assurance for determining long-term water-quality trends; and a professional staff.

  8. Nocturnal low-level jet and low-level cloud occurrence over Southern West Africa during DACCIWA campaign

    NASA Astrophysics Data System (ADS)

    Dione, Cheikh; Lohou, Fabienne; Lothon, Marie; Kaltoff, Norbert; Adler, Bianca; Babić, Karmen; Pedruzo-Bagazgoitia, Xabier

    2017-04-01

    During the summer monsoon period in West Africa, a nocturnal low-level jet (NLLJ) is frequently observed and is associated with the formation of a low-level deck of stratus or stratocumulus clouds over the southern domain of this region. The understanding of the mechanisms controlling the diurnal cycle of the low-level cloud (LLC) is one of the goals of the DACCIWA (Dynamics-aerosol-chemistry-cloud interactions in West Africa) project. During the ground campaign, which took place in June-July 2016, numerous instruments devoted to document the atmospheric boundary-layer dynamics and thermodynamics, clouds, aerosols and precipitation were deployed at Kumasi (Ghana), Savè (Benin) and Ile-Ife (Nigeria) supersites. Several parameters can influence the LLC formation: these are the large-scale conditions, but also local parameters such as stability, the interaction between Monsoon and Harmattan flows and turbulence. It has been pointed out in previous studies that the NLLJ plays a key role in LLC formation. Therefore, based on 49 nights of observations, our study focuses on the possible link between NLLJ and the formation, evolution and dissipation of the LLC over Savè. The characteristics of LLCs (onset, evolution and dissipation time, base height and thickness) are investigated using data from the ceilometer, infrared cloud camera, and frequent and normal radiosoundings. The UHF wind profiler data are used to estimate the occurrence of the NLLJ as well as the depth of the monsoon flow.

  9. Low-gravity Orbiting Research Laboratory Environment Potential Impact on Space Biology Research

    NASA Technical Reports Server (NTRS)

    Jules, Kenol

    2006-01-01

    One of the major objectives of any orbital space research platform is to provide a quiescent low gravity, preferably a zero gravity environment, to perform fundamental as well as applied research. However, small disturbances exist onboard any low earth orbital research platform. The impact of these disturbances must be taken into account by space research scientists during their research planning, design and data analysis in order to avoid confounding factors in their science results. The reduced gravity environment of an orbiting research platform in low earth orbit is a complex phenomenon. Many factors, among others, such as experiment operations, equipment operation, life support systems and crew activity (if it is a crewed platform), aerodynamic drag, gravity gradient, rotational effects as well as the vehicle structural resonance frequencies (structural modes) contribute to form the overall reduced gravity environment in which space research is performed. The contribution of these small disturbances or accelerations is precisely why the environment is NOT a zero gravity environment, but a reduced acceleration environment. This paper does not discuss other factors such as radiation, electromagnetic interference, thermal and pressure gradient changes, acoustic and CO2 build-up to name a few that affect the space research environment as well, but it focuses solely on the magnitude of the acceleration level found on orbiting research laboratory used by research scientists to conduct space research. For ease of analysis this paper divides the frequency spectrum relevant to most of the space research disciplines into three regimes: a) quasi-steady, b) vibratory and c) transient. The International Space Station is used as an example to illustrate the point. The paper discusses the impact of these three regimes on space biology research and results from space flown experiments are used to illustrate the potential negative impact of these disturbances (accelerations

  10. Delivering modern, high-quality, affordable pathology and laboratory medicine to low-income and middle-income countries: a call to action.

    PubMed

    Horton, Susan; Sullivan, Richard; Flanigan, John; Fleming, Kenneth A; Kuti, Modupe A; Looi, Lai Meng; Pai, Sanjay A; Lawler, Mark

    2018-05-12

    Modern, affordable pathology and laboratory medicine (PALM) systems are essential to achieve the 2030 Sustainable Development Goals for health in low-income and middle-income countries (LMICs). In this last in a Series of three papers about PALM in LMICs, we discuss the policy environment and emphasise three crucial high-level actions that are needed to deliver universal health coverage. First, nations need national strategic laboratory plans; second, these plans require adequate financing for implementation; and last, pathologists themselves need to take on leadership roles to advocate for the centrality of PALM to achieve the Sustainable Development Goals for health. The national strategic laboratory plan should deliver a tiered, networked laboratory system as a central element. Appropriate financing should be provided, at a level of at least 4% of health expenditure. Financing of new technologies such as molecular diagnostics is challenging for LMICs, even though many of these tests are cost-effective. Point-of-care testing can substantially reduce test-reporting time, but this benefit must be balanced with higher costs. Our research analysis highlights a considerable deficiency in advocacy for PALM; pathologists have been invisible in national and international health discourse and leadership. Embedding PALM in LMICs can only be achieved if pathologists advocate for these services, and undertake leadership roles, both nationally and internationally. We articulate eight key recommendations to address the current barriers identified in this Series and issue a call to action for all stakeholders to come together in a global alliance to ensure the effective provision of PALM services in resource-limited settings. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Study of the Low Level Wind Shear using AMDAR reports

    NASA Astrophysics Data System (ADS)

    Urlea, Ana-Denisa; Pietrisi, Mirela

    2015-04-01

    The aim of this work is the study of the effects of the wind shear on aircraft flights, in particularly when it appears on path of take-off or landing phase which is the most troublesome phase. This phenomenon has a lot of generating sources as: convection, frontal surfaces, strong surface wind coupled with local topography, breezes (either sea or mountain originated), mountain waves or low level temperature inversions. Low Level Jet is also a most frequent cause of Low Level Wind Shear. It has a lot of generating causes, but in Romania the most encountered is the presence of a Mediterranean low in southeastern part of Europe mainly in winter, sometimes in the first days of spring or the last days of autumn. It generates Low Level Wind Shear between surface and up to 600m, affecting approaching, landing or take-off phases of an aircraft flight. Diagnosis of meteorological general and local conditions and presence of Low Level Jet- generating Low Level Wind Shear is made using Meteo-France ARPEGE products model and ALARO high resolution model dedicated to Romanian area. The study is focused on use of real-time and in situ data as AMDAR (Aircraft Meteorological Data Relay) registrations with verification of a mobile Doppler SODAR registrations-("SOnic Detection And Ranging" system -PCS.2000- Metek manufactured by Meteorologische Messtechnik GMBH) in the processes of estimation of the quantitative and qualitative manifestation of Low Level Wind Shear. The results will be used to improve the timing and the accuracy of the Low Level Wind Shear forecasting for the aerodrome area.

  12. High Level Technology in a Low Level Mathematics Course.

    ERIC Educational Resources Information Center

    Schultz, James E.; Noguera, Norma

    2000-01-01

    Describes a teaching experiment in which spreadsheets and computer algebra systems were used to teach a low-level college consumer mathematics course. Students were successful in using different types of functions to solve a variety of problems drawn from real-world situations. Provides an existence proof that computer algebra systems can assist…

  13. Transcranial Low-Level Laser (Light) Therapy for Brain Injury

    PubMed Central

    Thunshelle, Connor

    2016-01-01

    Abstract Background: Low-level laser therapy (LLLT) or photobiomodulation (PBM) is a possible treatment for brain injury, including traumatic brain injury (TBI). Methods: We review the fundamental mechanisms at the cellular and molecular level and the effects on the brain are discussed. There are several contributing processes that have been proposed to lead to the beneficial effects of PBM in treating TBI such as stimulation of neurogenesis, a decrease in inflammation, and neuroprotection. Both animal and clinical trials for ischemic stroke are outlined. A number of articles have shown how transcranial LLLT (tLLLT) is effective at increasing memory, learning, and the overall neurological performance in rodent models with TBI. Results: Our laboratory has conducted three different studies on the effects of tLLLT on mice with TBI. The first studied pulsed against continuous laser irradiation, finding that 10 Hz pulsed was the best. The second compared four different wavelengths, discovering only 660 and 810 nm to have any effectiveness, whereas 732 and 980 nm did not. The third looked at varying regimens of daily laser treatments (1, 3, and 14 days) and found that 14 laser applications was excessive. We also review several studies of the effects of tLLLT on neuroprogenitor cells, brain-derived neurotrophic factor and synaptogenesis, immediate early response knockout mice, and tLLLT in combination therapy with metabolic inhibitors. Conclusions: Finally, some clinical studies in TBI patients are covered. PMID:28001759

  14. Laboratory Measurements of Celestial Solids

    NASA Technical Reports Server (NTRS)

    Sievers, A. J.; Beckwith, S. V. W.

    1997-01-01

    Our experimental study has focused on laboratory measurements of the low temperature optical properties of a variety of astronomically significant materials in the infrared and mm-wave region of the spectrum. Our far infrared measurements of silicate grains with an open structure have produced a variety of unusual results: (1) the low temperature mass opacity coefficient of small amorphous 2MgO(central dot)SiO2 and MgO(central dot)2SiO2 grains are many times larger than the values previously used for interstellar grain material; (2) all of the amorphous silicate grains studied possess the characteristic temperature dependent signature associated with two level systems in bulk glass; and (3) a smaller but nonzero two level temperature dependence signature is also observed for crystalline particles, its physical origin is unclear. These laboratory measurements yield surprisingly large and variable values for the mm-wave absorption coefficients of small silicate particles similar to interstellar grains, and suggest that the bulk absorptivity of interstellar dust at these long wavelengths will not be well known without such studies. Furthermore, our studies have been useful to better understand the physics of the two level absorption process in amorphous and crystalline grains to gain confidence in the wide applicability of these results.

  15. Interlaboratory tests for low-level radioactivity measurements in France

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Despres, M.

    In the framework of French national metrological coordination, the Laboratoire de Metrologie des Rayonnements Ionisants (LMRI) organizes every year an interlaboratory test program. The participation in these programs is on a voluntary basis and the results are presented in a nameless way. These tests concern radioactivity, neutron and dosimetry measurements. In this paper, a review of interlaboratory tests for low-level radioactivity measurements proposed by LMRI is given from 1975 to 1986. Every year, three types of tests are proposed: activity tests, multigamma tests, radioanalysis tests. For the last ten years, the number of results has been respectively 90 for activitymore » tests, 570 for multigamma tests and 400 for radioanalysis tests. The user's interest has increased, while the quality of results has improved. The deviations from LMRI's reference values are less than 3% for a restricted number of laboratories, and range between 3 and 10% for the majority of the others. The most urgent tests are for mixtures of {sup 90}Sr and activation and fission products in various matrices such as milk, grass, cereals, and sediments. 16 refs., 3 figs., 3 tabs.« less

  16. Student perceptions of an upper-level, undergraduate human anatomy laboratory course without cadavers.

    PubMed

    Wright, Shirley J

    2012-01-01

    Several programs in health professional education require or are considering requiring upper-level human anatomy as prerequisite for their applicants. Undergraduate students are confronted with few institutions offering such a course, in part because of the expense and logistical issues associated with a cadaver-based human anatomy course. This study describes the development of and student reactions to an upper-level human anatomy laboratory course for undergraduate students that used a regional approach and contemporary, alternative teaching methods to a cadaver-based course. The alternative pedagogy to deliver the curriculum included use of commercially available, three-dimensional anatomical virtual dissection software, anatomical models coupled with a learning management system to offer Web-based learning, and a new laboratory manual with collaborative exercises designed to develop the student's anatomical skills and collaborative team skills. A Likert-scale survey with open-ended questions was used to ascertain student perceptions of the course and its various aspects. Students perceived that the noncadaver-based, upper-level human anatomy course with an engaging, regional approach is highly valuable in their learning of anatomy. anatomy. Copyright © 2012 American Association of Anatomists.

  17. LOW LEVEL LOW ENERGY LOW QUANTITY SAMPLE COUNTING IN TRACER WORK

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hosain, F.

    1958-01-01

    A gas-flow Geiger counter has been set in anticoincidence with a ring of 10 Geiger-Mueller cosmic-ray counters and the whole assembly placed inside an iron castle. Radioactive samples can be introduced directly within the structure of the counter. The apparatus has been used in very low level tracer work with S/sup 35/, Fe/sup 55/, and I/sup 131/. (J.S.R.)

  18. Low-background Gamma Spectroscopy at Sanford Underground Laboratory

    NASA Astrophysics Data System (ADS)

    Chiller, Christopher; Alanson, Angela; Mei, Dongming

    2014-03-01

    Rare-event physics experiments require the use of material with unprecedented radio-purity. Low background counting assay capabilities and detectors are critical for determining the sensitivity of the planned ultra-low background experiments. A low-background counting, LBC, facility has been built at the 4850-Level Davis Campus of the Sanford Underground Research Facility to perform screening of material and detector parts. Like many rare event physics experiments, our LBC uses lead shielding to mitigate background radiation. Corrosion of lead brick shielding in subterranean installations creates radon plate-out potential as well as human risks of ingestible or respirable lead compounds. Our LBC facilities employ an exposed lead shield requiring clean smooth surfaces. A cleaning process of low-activity silica sand blasting and borated paraffin hot coating preservation was employed to guard against corrosion due to chemical and biological exposures. The resulting lead shield maintains low background contribution integrity while fully encapsulating the lead surface. We report the performance of the current LBC and a plan to develop a large germanium well detector for PMT screening. Support provided by Sd governors research center-CUBED, NSF PHY-0758120 and Sanford Lab.

  19. The European network of Biosafety-Level-4 laboratories: enhancing European preparedness for new health threats.

    PubMed

    Nisii, C; Castilletti, C; Di Caro, A; Capobianchi, M R; Brown, D; Lloyd, G; Gunther, S; Lundkvist, A; Pletschette, M; Ippolito, G

    2009-08-01

    Emerging and re-emerging infections and possible bioterrorism acts will continue to challenge both the medical community and civilian populations worldwide, urging health authorities to respond rapidly and effectively. Established in 2005, the European Community (EC)-funded European Network of Biosafety-Level-4 laboratories (Euronet-P4), which brings together the laboratories in Porton Down, London, Hamburg, Marburg, Solna, Lyon and Rome, seeks to increase international collaboration in the areas of high containment laboratory biosafety and viral diagnostic capability, to strengthen Europe's capacity to respond to an infectious disease emergency, and to offer assistance to countries not equipped with such costly facilities. Network partners have agreed on a common strategy to fill the gaps identified in the field of risk group-4 agents' laboratory diagnosis, namely the lack of standardization and of reference samples. The network has received a further 3-year funding, to offer assistance to external laboratories, and to start the planning of field activities.

  20. Credit WCT. Photographic copy of photograph, low level aerial view ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit WCT. Photographic copy of photograph, low level aerial view of Test Stand "D," looking due south, after completion of Dd station installation in 1961. Note Test Stand "D" "neutralization pond" to immediate southeast of tower. A steel barrier north of and parallel to the Dd station separates fuel run tanks (on south side obscured from view) from oxidizer run tanks (on north side). Small Dj injector test stand is visible to the immediate left of oxidizer run tanks; it is oriented on a northeast/southwest diagonal to the Dd test station. The large tank to the north of the oxidizer run tanks (near center bottom of view) is an oxidizer storage tank for nitrogen tetroxide. Slender tanks to the northwest of the tower (lower right of view) contain high pressure nitrogen gas. A large vertical tank at the base of the tower contains distilled water for flushing propellant lines. (JPL negative no. 384-2997-B, 12 December 1961) - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA

  1. Low-Cost Virtual Laboratory Workbench for Electronic Engineering

    ERIC Educational Resources Information Center

    Achumba, Ifeyinwa E.; Azzi, Djamel; Stocker, James

    2010-01-01

    The laboratory component of undergraduate engineering education poses challenges in resource constrained engineering faculties. The cost, time, space and physical presence requirements of the traditional (real) laboratory approach are the contributory factors. These resource constraints may mitigate the acquisition of meaningful laboratory…

  2. Investigating Macroscopic, Submicroscopic, and Symbolic Connections in a College-Level General Chemistry Laboratory

    ERIC Educational Resources Information Center

    Thadison, Felicia Culver

    2011-01-01

    Explanations of chemical phenomena rely on understanding the behavior of submicroscopic particles. Because this level is "invisible," it is described using symbols such as models, diagrams and equations. For this reason, students often view chemistry as a "difficult" subject. The laboratory offers a unique opportunity for the students to…

  3. EPA Region 6 Laboratory Method Specific Analytical Capabilities with Sample Concentration Range

    EPA Pesticide Factsheets

    EPA Region 6 Environmental Services Branch (ESB) Laboratory is capable of analyzing a wide range of samples with concentrations ranging for low part-per trillion (ppt) to low percent () levels, depending on the sample matrix.

  4. Lipid and lipoprotein testing in resource-limited laboratories.

    PubMed

    Myers, Gary L

    2003-01-01

    The role of total cholesterol (TC) and lipoproteins in the assessment of coronary heart disease (CHD) is firmly established from population and intervention studies. Total and low-density lipoprotein cholesterol (LDLC) levels are positively associated with CHD, and high-density lipoprotein cholesterol (HDLC) levels are negatively associated with CHD. Efforts to identify and treat people at increased risk based on cholesterol and lipoprotein levels have led to more lipid testing and the need for very reliable test results. Thus, quality laboratory services are an essential component of healthcare delivery and play a vital role in any strategy to reduce morbidity and mortality from CHD. In laboratories with limited resources, establishing laboratory capability to measure CHD risk markers may be a considerable challenge. Laboratories face problems in selecting proper techniques, difficulties in equipment availability and maintenance, and shortage of supplies, staffing, and supervision. The Centers for Disease Control and Prevention (CDC) has been providing technical assistance for more than 30 years to laboratories that measure lipids and lipoproteins and is willing to provide technical assistance as needed for other laboratories to develop this capability. CDC can provide technical assistance to establish lipid and lipoprotein testing capability to support a CHD public health program in areas with limited laboratory resources. This assistance includes: selecting a suitable testing instrument; providing training for laboratory technicians; establishing a simple quality control plan; and instructing staff on how to prepare frozen serum control materials suitable for assessing accuracy of lipid and lipoprotein testing.

  5. Laboratory studies of low temperature rate coefficients: The atmospheric chemistry of the outer planets

    NASA Technical Reports Server (NTRS)

    Leone, Stephen R.

    1993-01-01

    The objectives are to measure laboratory rate coefficients for key reactions of hydrocarbon molecules and radicals at low temperatures, which are relevant to the atmospheric photochemistry of Saturn, Jupiter, and Titan. Upcoming NASA planetary missions, such as Cassini, will probe the atmosphere of Titan in more detail, offering an excellent opportunity to test kinetic models and to establish fiducial standards for using kinetic models to interpret various parameters of the outer planets. Accurate low temperature kinetic data, which are presently lacking, may require crucial revisions to the rates of formation and destruction and are of utmost importance to the success of these efforts. In this program, several key reactions of ethynyl radicals (C2H) with acetylene (C2H2), methane (CH4), and oxygen (O2), down to temperatures of 170 K were successfully investigated. The experimental apparatus developed in our laboratory for measuring reaction kinetics at low temperatures consists of a laser photolysis/infrared probe laser setup. The rate measurements are carried out as a function of (low) temperature with a transverse flow cell designed specifically for these studies. A 193 nm argon fluoride pulsed excimer laser is used to photolyze a suitable precursor molecule, such as acetylene to produce C2H, and a high resolution, tunable infrared F-center laser (2.3-3.35 mu m) probes the transient concentrations of the radical species directly in absorption to extract the kinetic rate coefficients.

  6. Determining the hydraulic properties of saturated, low-permeability geological materials in the laboratory: Advances in theory and practice

    USGS Publications Warehouse

    Zhang, M.; Takahashi, M.; Morin, R.H.; Endo, H.; Esaki, T.; ,

    2002-01-01

    The accurate hydraulic characterization of low-permeability subsurface environments has important practical significance. In order to examine this issue from the perspective of laboratory-based approaches, we review some recent advancements in the theoretical analyses of three different laboratory techniques specifically applied to low-permeability geologic materials: constant-head, constant flow-rate and transient-pulse permeability tests. Some potential strategies for effectively decreasing the time required to confidently estimate the permeability of these materials are presented. In addition, a new and versatile laboratory system is introduced that can implement any of these three test methods while simultaneously subjecting a specimen to high confining pressures and pore pressures, thereby simulating in situ conditions at great depths. The capabilities and advantages of this innovative system are demonstrated using experimental data derived from Shirahama sandstone and Inada granite, two rock types widely encountered in Japan.

  7. A proposed intense slow positron source based on 58Co

    NASA Astrophysics Data System (ADS)

    Brown, Benjamin L.; Denison, Art; Makowitz, Henry; Gidley, Dave; Frieze, Bill; Griffin, Henry; Encarnación, Pedro

    1994-06-01

    Positron beams have proven very useful for condensed matter and surface research. The highest intensity of the current operating positron beams is ˜109 slow e+/second. The goal of our proposal is to build an Intense Slow Positron Source (ISPS) demonstration beam (Phase I) of unprecedented brightness at the Idaho National Engineering Laboratory, INEL (up to 1010 slow e+/s at 5 keV over a <0.03 cm. diameter). This Phase I beam will prove the principles necessary to build a larger facility scale ISPS Phase II beam which will have a potential of 1013 e+/s, or ≳1012 e+/s over 0.03 cm. The INEL is an ideal location for the ISPS because of the fast breeder reactor EBR-II, which is perfectly suited to creating the positron emitting isotope 58Co, and the excellent radioactive materials handling capability and expertise. Sufficient expertise is available at INEL for the construction and operation of a user facility (Phase II).

  8. An Upper Level Laboratory Course of Integrated Experiments

    ERIC Educational Resources Information Center

    Rose, T. L.; Seyse, R. J.

    1974-01-01

    Discusses the development of a one-year laboratory course in an effort to provide a link between traditional laboratories devoted to a single area of chemistry and the total involvement of a single narrow research project. Included are outlines of 32-hour lectures and 11 experiments performed in the integrated course. (CC)

  9. Significance and Clinical Management of Persistent Low-Level Viremia and Very-Low-Level Viremia in HIV-1-Infected Patients

    PubMed Central

    Kelly, Sean; Li, Jonathan Z.; Harrigan, P. Richard; Taiwo, Babafemi

    2014-01-01

    A goal of HIV therapy is to sustain suppression of the plasma viral load below the detection limits of clinical assays. However, widely followed treatment guidelines diverge in their interpretation and recommended management of persistent viremia of low magnitude, reflecting the limited evidence base for this common clinical finding. Here, we review the incidence, risk factors, and potential consequences of low-level HIV viremia (LLV; defined in this review as a viremia level of 50 to 500 copies/ml) and very-low-level viremia (VLLV; defined as a viremia level of <50 copies/ml detected by clinical assays that have quantification cutoffs of <50 copies/ml). Using this framework, we discuss practical issues related to the diagnosis and management of patients experiencing persistent LLV and VLLV. Compared to viral suppression at <50 or 40 copies/ml, persistent LLV is associated with increased risk of antiretroviral drug resistance and overt virologic failure. Higher immune activation and HIV transmission may be additional undesirable consequences in this population. It is uncertain whether LLV of <200 copies/ml confers independent risks, as this level of viremia may reflect assay-dependent artifacts or biologically meaningful events during suppression. Resistance genotyping should be considered in patients with persistent LLV when feasible, and treatment should be modified if resistance is detected. There is a dearth of clinical evidence to guide management when genotyping is not feasible. Increased availability of genotypic assays for samples with viral loads of <400 copies/ml is needed. PMID:24733471

  10. Revisions of Physical Geology Laboratory Courses to Increase the Level of Inquiry: Implications for Teaching and Learning

    ERIC Educational Resources Information Center

    Grissom, April N.; Czajka, C. Douglas; McConnell, David A.

    2015-01-01

    The introductory physical geology laboratory courses taught at North Carolina State University aims to promote scientific thinking and learning through the use of scientific inquiry-based activities. A rubric describing five possible levels of inquiry was applied to characterize the laboratory activities in the course. Two rock and mineral…

  11. The Adriatic Sea: A Long-Standing Laboratory for Sea Level Studies

    NASA Astrophysics Data System (ADS)

    Vilibić, Ivica; Šepić, Jadranka; Pasarić, Mira; Orlić, Mirko

    2017-10-01

    The paper provides a comprehensive review of all aspects of Adriatic Sea level research covered by the literature. It discusses changes occurring over millennial timescales and documented by a variety of natural and man-made proxies and post-glacial rebound models; mean sea level changes occurring over centennial to annual timescales and measured by modern instruments; and daily and higher-frequency changes (with periods ranging from minutes to a day) that are contributing to sea level extremes and are relevant for present-day flooding of coastal areas. Special tribute is paid to the historic sea level studies that shaped modern sea level research in the Adriatic, followed by a discussion of existing in situ and remote sensing observing systems operating in the Adriatic area, operational forecasting systems for Adriatic storm surges, as well as warning systems for tsunamis and meteotsunamis. Projections and predictions of sea level and related hazards are also included in the review. Based on this review, open issues and research gaps in the Adriatic Sea level studies are identified, as well as the additional research efforts needed to fill the gaps. The Adriatic Sea, thus, remains a laboratory for coastal sea level studies for semi-enclosed, coastal and marginal seas in the world ocean.

  12. The Effect of Chemistry Laboratory Activities on Students' Chemistry Perception and Laboratory Anxiety Levels

    ERIC Educational Resources Information Center

    Aydogdu, Cemil

    2017-01-01

    Chemistry lesson should be supported with experiments to understand the lecture effectively. For safety laboratory environment and to prevent laboratory accidents; chemical substances' properties, working principles for chemical substances' usage should be learnt. Aim of the present study was to analyze the effect of experiments which depend on…

  13. 15. VIEW OF DUMMY FUEL ELEMENT ON FUEL ELEMENT HOLDER. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. VIEW OF DUMMY FUEL ELEMENT ON FUEL ELEMENT HOLDER. SHOWS AIR FORCE MAN AT EDGE OF TANK. INEL PHOTO NUMBER 65-6176, TAKEN NOVEMBER 10, 1965. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  14. Effects of delayed laboratory processing on platelet serotonin levels.

    PubMed

    Sanner, Jennifer E; Frazier, Lorraine; Udtha, Malini

    2013-01-01

    Despite the availability of established guidelines for measuring platelet serotonin, these guidelines may be difficult to follow in a hospital setting where time to processing may vary from sample to sample. The purpose of this study was to evaluate the effect of the time to processing of human blood samples on the stability of the enzyme-linked immunosorbent assay (ELISA) for the determination of platelet serotonin levels in human plasma. Human blood samples collected from a convenience sample of eight healthy volunteers were analyzed to determine platelet serotonin levels from plasma collected in ethylene diamine tetra acetic acid (EDTA) tubes and stored at 4°C for 3 hr, 5 hr, 8 hr, and 12 hr. Refrigeration storage at 4°C for 3 hr, 5 hr, 8 hr, and 12 hr altered the platelet serotonin measurement when compared to immediate processing. The bias for the samples stored at 4°C for 3 hr was 102.3 (±217.39 ng/10(9) platelets), for 5 hr was 200.1 (±132.76 ng/10(9) platelets), for 8 hr was 146.9 (±221.41 ng/10(9) platelets), and for 12 hr was -67.6 (±349.60 ng/10(9) platelets). Results from this study show that accurate measurement of platelet serotonin levels is dependent on time to processing. Researchers should therefore follow a standardized laboratory guideline for obtaining immediate platelet serotonin levels after blood sample collection.

  15. SwarmSight: Measuring the Temporal Progression of Animal Group Activity Levels from Natural Scene and Laboratory Videos

    PubMed Central

    Birgiolas, Justas; Jernigan, Christopher M.; Smith, Brian H.; Crook, Sharon M.

    2016-01-01

    We describe SwarmSight (available at: https://github.com/justasb/SwarmSight), a novel, open-source, Microsoft Windows software tool for quantitative assessment of the temporal progression of animal group activity levels from recorded videos. The tool utilizes a background subtraction machine vision algorithm and provides an activity metric that can be used to quantitatively assess and compare animal group behavior. Here we demonstrate the tool utility by analyzing defensive bee behavior as modulated by alarm pheromones, wild bird feeding onset and interruption, and cockroach nest finding activity. While more sophisticated, commercial software packages are available, SwarmSight provides a low-cost, open-source, and easy-to-use alternative that is suitable for a wide range of users, including minimally trained research technicians and behavioral science undergraduate students in classroom laboratory settings. PMID:27130170

  16. Xeroderma pigmentosum cells contain low levels of photoreactivating enzyme.

    PubMed Central

    Sutherland, B M; Rice, M; Wagner, E K

    1975-01-01

    Fibroblasts from patients with xeroderma pigmentosum contain low levels of photoreactivating enzyme in comparison to normal cells. Levels vary from 0 (line 1199) to 50 (line 1259) percent of normal. The depressed enzyme levels are not an artifact of low growth rate, age of cell donor, cell culture conditions, assay conditions, the presence of inhibitors, or mycoplasma contamination. We show that human fibroblasts can monomerize pyrimidine dimers in vivo. PMID:1054487

  17. SUNLAB - The Project of a Polish Underground Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kisiel, J.; Dorda, J.; Konefall, A.

    2010-11-24

    The project of the first Polish underground laboratory SUNLAB, in the Polkowice-Sieroszowice copper mine, belonging to the KGHM Polska Miedz S.A. holding, is presented. Two stages of the project are foreseen: SUNLAB1 (a small laboratory in the salt layer exhibiting extremely low level of natural radioactivity) and SUNLAB2 (a big laboratory in the anhydrite layer, able to host the next generation liquid argon detector - GLACIER, which is considered within the LAGUNA FP7 project). The results of the natural radioactivity background measurements performed in the Polkowice-Sieroszowice salt cavern are also briefly summarized.

  18. SUNLAB-The Project of a Polish Underground Laboratory

    NASA Astrophysics Data System (ADS)

    Kisiel, J.; Budzanowski, M.; Chorowski, M.; Cygan, S.; Dorda, J.; Hanzel, S.; Harańczyk, M.; Horoszczak, L.; Januszewska, K.; Jaroń, L.; Konefalł, A.; Kozak, K.; Lankof, L.; Mania, S.; Markiewicz, A.; Markowski, P.; Mazur, J.; Mertuszka, P.; Mietelski, J. W.; Poliński, J.; Puchalska, M.; Pytel, W.; Raczyński, M.; Sadecki, Z.; Sadowski, A.; Ślizowski, J.; Sulej, R.; Szarska, M.; Szeglowski, T.; Tomankiewicz, E.; Urbańczyk, K.; Zalewska, A.

    2010-11-01

    The project of the first Polish underground laboratory SUNLAB, in the Polkowice-Sieroszowice copper mine, belonging to the KGHM Polska Miedź S.A. holding, is presented. Two stages of the project are foreseen: SUNLAB1 (a small laboratory in the salt layer exhibiting extremely low level of natural radioactivity) and SUNLAB2 (a big laboratory in the anhydrite layer, able to host the next generation liquid argon detector-GLACIER, which is considered within the LAGUNA FP7 project). The results of the natural radioactivity background measurements performed in the Polkowice-Sieroszowice salt cavern are also briefly summarized.

  19. A digital retina-like low-level vision processor.

    PubMed

    Mertoguno, S; Bourbakis, N G

    2003-01-01

    This correspondence presents the basic design and the simulation of a low level multilayer vision processor that emulates to some degree the functional behavior of a human retina. This retina-like multilayer processor is the lower part of an autonomous self-organized vision system, called Kydon, that could be used on visually impaired people with a damaged visual cerebral cortex. The Kydon vision system, however, is not presented in this paper. The retina-like processor consists of four major layers, where each of them is an array processor based on hexagonal, autonomous processing elements that perform a certain set of low level vision tasks, such as smoothing and light adaptation, edge detection, segmentation, line recognition and region-graph generation. At each layer, the array processor is a 2D array of k/spl times/m hexagonal identical autonomous cells that simultaneously execute certain low level vision tasks. Thus, the hardware design and the simulation at the transistor level of the processing elements (PEs) of the retina-like processor and its simulated functionality with illustrative examples are provided in this paper.

  20. INEL BNCT Research Program Annual Report 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Venhuizen, J.R.

    1994-08-01

    This report is a summary of the progress and research produced for the Idaho National Engineering Laboratory Boron Neutron Capture Therapy Research Program for calendar year 1993. Contributions from all the principal investigators are included, covering chemistry (pituitary tumor studies, boron drug development including liposomes, lipoproteins, and carboranylalanine derivatives), pharmacology (murine screenings, toxicity testing, boron drug analysis), physics (radiation dosimetry software, neutron beam and filter design, neutron beam measurement dosimetry), and radiation biology (tissue and efficacy studies of small and large animal models). Information on the potential toxicity of borocaptate sodium and boronophenylalanine is presented. Results of 21 spontaneous-tumor-bearing dogsmore » that have been treated with boron neutron capture therapy at the Brookhaven National Laboratory are updated. Boron-containing drug purity verification is discussed in some detail. Advances in magnetic resonance imaging of boron in vivo are discussed. Several boron-carrying drugs exhibiting good tumor uptake are described. Significant progress in the potential of treating pituitary tumors is presented. Measurement of the epithermal-neutron flux of the Petten (The Netherlands) High Flux Reactor beam (HFB11B), and comparison to predictions are shown.« less

  1. Measurement Challenges at Low Blood Lead Levels.

    PubMed

    Caldwell, Kathleen L; Cheng, Po-Yung; Jarrett, Jeffery M; Makhmudov, Amir; Vance, Kathryn; Ward, Cynthia D; Jones, Robert L; Mortensen, Mary E

    2017-08-01

    In 2012, the Centers for Disease Control and Prevention (CDC) adopted its Advisory Committee on Childhood Lead Poisoning Prevention recommendation to use a population-based reference value to identify children and environments associated with lead hazards. The current reference value of 5 μg/dL is calculated as the 97.5th percentile of the distribution of blood lead levels (BLLs) in children 1 to 5 years old from 2007 to 2010 NHANES data. We calculated and updated selected percentiles, including the 97.5th percentile, by using NHANES 2011 to 2014 blood lead data and examined demographic characteristics of children whose blood lead was ≥90th percentile value. The 97.5th percentile BLL of 3.48 µg/dL highlighted analytical laboratory and clinical interpretation challenges of blood lead measurements ≤5 μg/dL. Review of 5 years of results for target blood lead values <11 µg/dL for US clinical laboratories participating in the CDC's voluntary Lead and Multi-Element Proficiency quality assurance program showed 40% unable to quantify and reported a nondetectable result at a target blood lead value of 1.48 µg/dL, compared with 5.5% at a target BLL of 4.60 µg/dL. We describe actions taken at the CDC's Environmental Health Laboratory in the National Center for Environmental Health, which measures blood lead for NHANES, to improve analytical accuracy and precision and to reduce external lead contamination during blood collection and analysis. Copyright © 2017 by the American Academy of Pediatrics.

  2. LOW LEVEL COUNTING TECHNIQUES WITH SPECIAL REFERENCE TO BIOMEDICAL TRACER PROBLEMS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hosain, F.; Nag, B.D.

    1959-12-01

    Low-level counting techniques in tracer experiments are discussed with emphasis on the measurement of beta and gamma radiations with Geiger and scintillation counting methods. The basic principles of low-level counting are outlined. Screen-wall counters, internal gas counters, low-level beta counters, scintillation spectrometers, liquid scintillators, and big scintillation installations are described. Biomedical tracer investigations are discussed. Applications of low-level techniques in archaeological dating, biology, and other problems are listed. (M.C.G.)

  3. Midwest Interstate Low-Level Radioactive Waste Commission annual report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1988-08-01

    In 1980, Congress passed the Low-Level Radioactive Waste Policy Act. This Act provided for a new approach to the disposal of low-level radioactive waste. It assigned each state responsibility for the disposal of low-level radioactive waste generated within its borders, and it authorized states to enter into compacts for the purpose of operating regional disposal facilities. It also authorized compacts to restrict the use of regional disposal facilities to only member states. To meet their obligations under the Act, Indiana, Iowa, Michigan, Minnesota, Missouri, Ohio and Wisconsin formed the Midwest Interstate Low-Level Radioactive Waste Compact. The Compact was ratified bymore » each of the state legislatures and by Congress. The Compact established the Midwest Interstate Low-Level Radioactive Waste Commission, composed on one representative appointed by the Governor or Legislature of each member state. Article 3 of the compact requires that the Commission prepare an annual report regarding the activities and actions of the Commission. It also requires that the annual report be distributed to the Governors and legislative leaders in the member states. The Commission's Bylaw Article 12 requires the annual report to cover the preceding fiscal year, and to be distributed in August of each year. The Bylaw also requires that an annual audit, prepared by a certified public accountant, be included as part of the annual report. 3 figs.« less

  4. 77 FR 25760 - Low-Level Radioactive Waste Management and Volume Reduction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-01

    ... NUCLEAR REGULATORY COMMISSION [NRC-2011-0183] Low-Level Radioactive Waste Management and Volume.... Nuclear Regulatory Commission (NRC or the Commission) is revising its 1981 Policy Statement on Low-Level..., the NRC staff issued SECY-10-0043, ``Blending of Low-Level Radioactive Waste'' (ADAMS Accession No...

  5. Investigation of a Chaotic Double Pendulum in the Basic Level Physics Teaching Laboratory

    ERIC Educational Resources Information Center

    Vanko, Peter

    2007-01-01

    First-year physics students at the Technical University of Budapest carry out a wide range of measurements in the Basic Level Physics Teaching Laboratory. One of the most exciting experiments is the investigation of a chaotic double pendulum by a V-scope, a powerful three-dimensional motion tracking system. After a brief introduction to the…

  6. Certification & validation of biosafety level-2 & biosafety level-3 laboratories in Indian settings & common issues.

    PubMed

    Mourya, Devendra T; Yadav, Pragya D; Khare, Ajay; Khan, Anwar H

    2017-10-01

    With increasing awareness regarding biorisk management worldwide, many biosafety laboratories are being setup in India. It is important for the facility users, project managers and the executing agencies to understand the process of validation and certification of such biosafety laboratories. There are some international guidelines available, but there are no national guidelines or reference standards available in India on certification and validation of biosafety laboratories. There is no accredited government/private agency available in India to undertake validation and certification of biosafety laboratories. Therefore, the reliance is mostly on indigenous experience, talent and expertise available, which is in short supply. This article elucidates the process of certification and validation of biosafety laboratories in a concise manner for the understanding of the concerned users and suggests the important parameters and criteria that should be considered and addressed during the laboratory certification and validation process.

  7. Falsely elevated sodium levels during thiopental treatment in the ICU: technical interference on a laboratory device with important clinical relevance.

    PubMed

    Feyen, Bart F E; Coenen, Dries; Jorens, Philippe G; Wouters, Kristien; Maas, Andrew I R; Van Hoof, Viviane; Verbrugghe, Walter

    2013-02-01

    Thiopental is a cornerstone in the treatment of refractory status epilepticus and intractable intracranial hypertension. In our center we observed that thiopental might cause falsely elevated serum sodium levels. Triggered by a recent case experience of extremely elevated serum sodium levels during thiopental treatment, we retrospectively identified 53 patients treated with thiopental in our intensive care unit between 2007 and 2011 and evaluated electrolyte changes. We differentiated the analysis before and after introduction of a new device for sodium assays (Dimension Vista, Siemens) in the central laboratory in April 2010. Standardized in vitro laboratory tests were performed to study the effect of thiopental on sodium analysis. Before April 2010, serum sodium levels determined in the central laboratory showed a good agreement with the bedside point-of-care (POC) device during thiopental therapy with [sodium](laboratory) - [sodium](POC) of only 1.08 mmol/L (P = .0517). After April 2010, a strong discrepancy between laboratory values and POC values was observed with [sodium](laboratory) - [sodium](POC) = 11.57 mmol/L (P < .0001). Standardized in vitro testing confirmed that thiopental induced a dose-dependent false hypernatremia (P = .002). Thiopental treatment can result in falsely elevated serum sodium. This is a critical finding since high sodium levels preclude administrating mannitol or hypertonic saline for the treatment of elevated intracranial pressure. Moreover, a false high sodium level might lead to the inappropriate administration of hypotonic fluids potentially resulting in increased brain edema and even higher intracranial pressure. To our knowledge, this is the first paper describing this clinically relevant phenomenon.

  8. Impact-based piezoelectric energy harvester for multidimensional, low-level, broadband, and low-frequency vibrations

    NASA Astrophysics Data System (ADS)

    Zhang, Hongjiang; Jiang, Senlin; He, Xuefeng

    2017-05-01

    This letter proposes an impact-based piezoelectric energy harvester that uses a rolling bead contained in a bracket that is supported by a spring. Under either translational or rotational base excitation, the bead moves within the bracket and collides with piezoelectric cantilevers that are located around the bracket; these collisions cause the piezoelectric beams to vibrate and thus produce electrical outputs. The low rolling friction and the motion amplification effect of the spring make the resulting device suitable for collection of low-level vibration energy. Experiments show that the proposed harvester is promising for use in scavenging of energy from the multidimensional, low-level, broadband, and low-frequency vibrations that occur in natural environments.

  9. 20. VIEW OF TEST FACILITY IN 1967 WHEN EQUIPPED FOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    20. VIEW OF TEST FACILITY IN 1967 WHEN EQUIPPED FOR DOSIMETER TEST BY HEALTH PHYSICISTS. CAMERA FACING EAST. INEL PHOTO NUMBER 76-2853, TAKEN MAY 16, 1967. PHOTOGRAPHER: CAPEK. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  10. 34. DETAILS AND SECTIONS OF SHIELDING TANK FUEL ELEMENT SUPPORT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    34. DETAILS AND SECTIONS OF SHIELDING TANK FUEL ELEMENT SUPPORT FRAME. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-S-4. INEL INDEX CODE NUMBER: 075 0701 60 851 151978. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  11. 6. CONSTRUCTION PROGRESS VIEW (EXTERIOR) OF TANK, CABLE CHASE, AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. CONSTRUCTION PROGRESS VIEW (EXTERIOR) OF TANK, CABLE CHASE, AND MOUNDED BUNKER. CONSTRUCTION WAS 99 PERCENT COMPLETE. CAMERA IS FACING WEST. INEL PHOTO NUMBER 65-5435, TAKEN OCTOBER 20, 1965. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  12. 17. INTERIOR VIEW INSIDE BUNKER. MAN SEATED AT LEFT LOOKS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. INTERIOR VIEW INSIDE BUNKER. MAN SEATED AT LEFT LOOKS AT OPENING TO CABLE CHASE, HIS HANDS ON MANUALLY-OPERATED PULLEY. INEL PHOTO NUMBER 65-6179, TAKEN NOVEMBER 10, 1965. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  13. Certification & validation of biosafety level-2 & biosafety level-3 laboratories in Indian settings & common issues

    PubMed Central

    Mourya, Devendra T.; Yadav, Pragya D.; Khare, Ajay; Khan, Anwar H.

    2017-01-01

    With increasing awareness regarding biorisk management worldwide, many biosafety laboratories are being setup in India. It is important for the facility users, project managers and the executing agencies to understand the process of validation and certification of such biosafety laboratories. There are some international guidelines available, but there are no national guidelines or reference standards available in India on certification and validation of biosafety laboratories. There is no accredited government/private agency available in India to undertake validation and certification of biosafety laboratories. Therefore, the reliance is mostly on indigenous experience, talent and expertise available, which is in short supply. This article elucidates the process of certification and validation of biosafety laboratories in a concise manner for the understanding of the concerned users and suggests the important parameters and criteria that should be considered and addressed during the laboratory certification and validation process. PMID:29434059

  14. To What Extent Does A-Level Physics Prepare Students for Undergraduate Laboratory Work?

    ERIC Educational Resources Information Center

    Thompson, Alaric

    2012-01-01

    This paper is a summary of a small-scale research project carried out to investigate the transition from A-level to university physics, with a specific focus on practical or laboratory skills. A brief description of the methods used precedes the headline findings of the research. A non-evidential discussion of the possible reasons behind any…

  15. Effect of low-level laser stimulation on EEG.

    PubMed

    Wu, Jih-Huah; Chang, Wen-Dien; Hsieh, Chang-Wei; Jiang, Joe-Air; Fang, Wei; Shan, Yi-Chia; Chang, Yang-Chyuan

    2012-01-01

    Conventional laser stimulation at the acupoint can induce significant brain activation, and the activation is theoretically conveyed by the sensory afferents. Whether the insensible low-level Laser stimulation outside the acupoint could also evoke electroencephalographic (EEG) changes is not known. We designed a low-level laser array stimulator (6 pcs laser diode, wavelength 830 nm, output power 7 mW, and operation frequency 10 Hz) to deliver insensible laser stimulations to the palm. EEG activities before, during, and after the laser stimulation were collected. The amplitude powers of each EEG frequency band were analyzed. We found that the low-level laser stimulation was able to increase the power of alpha rhythms and theta waves, mainly in the posterior head regions. These effects lasted at least 15 minutes after cessation of the laser stimulation. The amplitude power of beta activities in the anterior head regions decreased after laser stimulation. We thought these EEG changes comparable to those in meditation.

  16. Low gravity liquid level sensor rake

    NASA Technical Reports Server (NTRS)

    Grayson, Gary D. (Inventor); Craddock, Jeffrey C. (Inventor)

    2003-01-01

    The low gravity liquid level sensor rake measures the liquid surface height of propellant in a propellant tank used in launch and spacecraft vehicles. The device reduces the tendency of the liquid propellant to adhere to the sensor elements after the bulk liquid level has dropped below a given sensor element thereby reducing the probability of a false liquid level measurement. The liquid level sensor rake has a mast attached internal to a propellant tank with an end attached adjacent the tank outlet. Multiple sensor elements that have an arm and a sensor attached at a free end thereof are attached to the mast at locations selected for sensing the presence or absence of the liquid. The sensor elements when attached to the mast have a generally horizontal arm and a generally vertical sensor.

  17. Measurement of low turbulence levels with a thermoanemometer

    NASA Technical Reports Server (NTRS)

    Demin, V. S.; Morin, O. V.; Polyakov, N. F.; Shcherbakov, V. A.

    1978-01-01

    The trend for decreasing the drag of aircraft is retention of laminar flow in the boundary layer over a large portion of the surface. The laminar boundary layer was studied in a low turbulence wind tunnel for low subsonic velocities. The method used and results of measurements of very low levels of turbulence are presented. Measurements were performed by a constant-resistance thermoanemometer.

  18. Results of ultra-low level 71ge counting for application in the Gallex-solar neutrino experiment at the Gran Sasso Underground Physics Laboratory

    NASA Technical Reports Server (NTRS)

    Hampel, W.; Heusser, G.; Huebner, M.; Kiko, J.; Kirsten, T.; Schneider, K.; Schlotz, R.

    1985-01-01

    It has been experimentally verified that the Ultra-Low-Level Counting System for the Gallex solar neutrino experiment is capable of measuring the expected solar up silon-flux to plus or minus 12% during two years of operation.

  19. Correspondence between Maternal Determination of Child Fullness and Young Children's Self-Determined Fullness Level: Results from a Standardized Laboratory Protocol

    PubMed Central

    Thompson, Debbe; Power, Thomas G.; Hughes, Sheryl O.

    2015-01-01

    Abstract Background: This study examined maternal understanding and acceptance of young children's ability to self-assess fullness using a mixed-methods approach. Methods: Twenty low-income mothers of 5- to 7-year-olds participated in this semistructured laboratory study. After consumption of a buffet dinner meal, mothers were asked to indicate their perception of their child's fullness level, and children were also asked to self-assess their fullness level. Results: Five of the 20 mothers in the study were initially correct in their assessment of their child's level of fullness. Half of the incorrect mothers were willing to change their rating when informed that the child's fullness rating was different than her own. Conclusions: Semistructured interview results provide suggestive evidence that some mothers believe they understand their child's fullness level better than their children. Given that mothers have the potential to override children's ability to self-regulate eating behavior, teaching mothers to understand and appreciate young children's ability to self-regulate eating is an important area for intervention. PMID:25692707

  20. Emulation-Based Virtual Laboratories: A Low-Cost Alternative to Physical Experiments in Control Engineering Education

    ERIC Educational Resources Information Center

    Goodwin, G. C.; Medioli, A. M.; Sher, W.; Vlacic, L. B.; Welsh, J. S.

    2011-01-01

    This paper argues the case for emulation-based virtual laboratories in control engineering education. It demonstrates that such emulation experiments can give students an industrially relevant educational experience at relatively low cost. The paper also describes a particular emulation-based system that has been developed with the aim of giving…

  1. Glasses for immobilization of low- and intermediate-level radioactive waste

    NASA Astrophysics Data System (ADS)

    Laverov, N. P.; Omel'yanenko, B. I.; Yudintsev, S. V.; Stefanovsky, S. V.; Nikonov, B. S.

    2013-03-01

    Reprocessing of spent nuclear fuel (SNF) for recovery of fissionable elements is a precondition of long-term development of nuclear energetics. Solution of this problem is hindered by the production of a great amount of liquid waste; 99% of its volume is low- and intermediate-level radioactive waste (LILW). The volume of high-level radioactive waste (HLW), which is characterized by high heat release, does not exceed a fraction of a percent. Solubility of glasses at an elevated temperature makes them unfit for immobilization of HLW, the insulation of which is ensured only by mineral-like matrices. At the same time, glasses are a perfect matrix for LILW, which are distinguished by low heat release. The solubility of borosilicate glass at a low temperature is so low that even a glass with relatively low resistance enables them to retain safety of under-ground LILW depositories without additional engineering barriers. The optimal technology of liquid confinement is their concentration and immobilization in borosilicate glasses, which are disposed in shallow-seated geological repositories. The vitrification of 1 m3 liquid LILW with a salt concentration of ˜300 kg/m3 leaves behind only 0.2 m3 waste, that is, 4-6 times less than by bitumen impregnation and 10 times less than by cementation. Environmental and economic advantages of LILW vitrification result from (1) low solubility of the vitrified LILW in natural water; (2) significant reduction of LILW volume; (3) possibility to dispose the vitrified waste without additional engineering barriers under shallow conditions and in diverse geological media; (4) the strength of glass makes its transportation and storage possible; and finally (5) reliable longterm safety of repositories. When the composition of the glass matrix for LILW is being chosen, attention should be paid to the factors that ensure high technological and economic efficiency of vitrification. The study of vitrified LILW from the Kursk nuclear power plant

  2. A Computerized Data-Capture System for Animal Biosafety Level 4 Laboratories

    PubMed Central

    Bente, Dennis A; Friesen, Jeremy; White, Kyle; Koll, Jordan; Kobinger, Gary P

    2011-01-01

    The restrictive nature of an Animal Biosafety Level 4 (ABSL4) laboratory complicates even simple clinical evaluation including data capture. Typically, clinical data are recorded on paper during procedures, faxed out of the ABSL4, and subsequently manually entered into a computer. This system has many disadvantages including transcriptional errors. Here, we describe the development of a highly customizable, tablet-PC-based computerized data-capture system, allowing reliable collection of observational and clinical data from experimental animals in a restrictive biocontainment setting. A multidisciplinary team with skills in containment laboratory animal science, database design, and software engineering collaborated on the development of this system. The goals were to design an easy-to-use and flexible user interface on a touch-screen tablet PC with user-supportable processes for recovery, full auditing capabilities, and cost effectiveness. The system simplifies data capture, reduces the necessary time in an ABSL4 environment, offers timely reporting and review of data, facilitates statistical analysis, reduces potential of erroneous data entry, improves quality assurance of animal care, and advances the use and refinement of humane endpoints. PMID:22330712

  3. Low-level lasers on microRNA and uncoupling protein 2 mRNA levels in human breast cancer cells

    NASA Astrophysics Data System (ADS)

    Canuto, K. S.; Teixeira, A. F.; Rodrigues, J. A.; Paoli, F.; Nogueira, E. M.; Mencalha, A. L.; Fonseca, A. S.

    2017-06-01

    MicroRNA is short non-coding RNA and is a mediator of post-transcriptional regulation of gene expression. In addition, uncoupling proteins (UCPs) regulate thermogenesis, metabolic and energy balance, and decrease reactive oxygen species production. Both microRNA and UCP2 expression can be altered in cancer cells. At low power, laser wavelength, frequency, fluence and emission mode deternube photobiological responses, which are the basis of low-level laser therapy. There are few studies on miRNA and UCP mRNA levels after low-level laser exposure on cancer cells. In this work, we evaluate the micrRNA (mir-106b and mir-15a) and UCP2 mRNA levels in human breast cancer cells exposed to low-level lasers. MDA-MB-231 human breast cancer cells were exposed to low-level red and infrared lasers, total RNA was extracted for cDNA synthesis and mRNA levels by real time quantitative polymerase chain reaction were evaluated. Data show that mir-106b and mir-15a relative levels are not altered, but UCP2 mRNA relative levels are increased in MDA-MB-231 human breast cancer cells exposed to low-level red and infrared lasers at fluences used in therapeutic protocols.

  4. Low glucose level and low pH alter the electrochemical function of human parietal pleura.

    PubMed

    Kouritas, V K; Hatzoglou, C; Foroulis, C N; Hevas, A; Gourgoulianis, K I; Molyvdas, P A

    2007-08-01

    The aim of the present study was to investigate whether low glucose and pH level, which are usually measured in complicated pleural effusions, alter the electrochemical function of healthy human parietal pleura. Parietal pleural pieces were stripped from 66 patients during thoracic surgery and were mounted in Ussing chambers. Krebs' solutions containing different glucose levels (0, 40 and 100 mg) and balanced at different pH levels (7.4, 7.3 and 7.2) were added to the pleural cavity surface of the pieces. Transmesothelial potential difference was measured at various time-points as an electrophysiological variable and transmesothelial resistance (R(TM)) was calculated using Ohm's law. When normal-glucose Krebs at pH 7.45 was used, R(TM) remained unchanged over time, but when low-glucose Krebs was used, R(TM) decreased. Krebs without glucose caused the greatest decrease in R(TM). Use of low-pH Krebs decreased R(TM). The lower the pH of the Krebs, the faster the decrease in R(TM) and the greater the effect. The decrease in R(TM) was greater with low-pH than with low-glucose Krebs. Low glucose and low pH caused an additive decrease in R(TM). Low glucose concentration and low pH cause alteration of the electrochemical function of human parietal pleura and could act as agents that lead to further exudate progression.

  5. [Factors associated with low levels of aerobic fitness among adolescents].

    PubMed

    Gonçalves, Eliane Cristina de Andrade; Silva, Diego Augusto Santos

    2016-06-01

    To evaluate the prevalence of low aerobic fitness levels and to analyze the association with sociodemographic factors, lifestyle and excess body fatness among adolescents of southern Brazil. The study included 879 adolescents aged 14 to 19 years the city of São José/SC, Brazil. The aerobic fitness was assessed by Canadian modified test of aerobic fitness. Sociodemographic variables (skin color, age, sex, study turn, economic level), sexual maturation and lifestyle (eating habits, screen time, physical activity, consumption of alcohol and tobacco) were assessed by a self-administered questionnaire. Excess body fatness was evaluated by sum of skinfolds triceps and subscapular. We used logistic regression to estimate odds ratios and 95% confidence intervals. Prevalence of low aerobic fitness level was 87.5%. The girls who spent two hours or more in front screen, consumed less than one glass of milk by day, did not smoke and had an excess of body fatness had a higher chance of having lower levels of aerobic fitness. White boys with low physical activity had had a higher chance of having lower levels of aerobic fitness. Eight out of ten adolescents were with low fitness levels aerobic. Modifiable lifestyle factors were associated with low levels of aerobic fitness. Interventions that emphasize behavior change are needed. Copyright © 2015 Sociedade de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.

  6. Low oxytocin levels are related to alexithymia in anorexia nervosa.

    PubMed

    Schmelkin, Cindy; Plessow, Franziska; Thomas, Jennifer J; Gray, Emily K; Marengi, Dean A; Pulumo, Reitumetse; Silva, Lisseth; Miller, Karen K; Hadjikhani, Nouchine; Franko, Debra L; Eddy, Kamryn T; Lawson, Elizabeth A

    2017-11-01

    Anorexia nervosa is associated with social-emotional functioning deficits and low levels of the social neurohormone oxytocin, even after weight gain. The relationship between low oxytocin levels and social-emotional functioning impairment has not been studied. We performed a cross-sectional study of 79 women (19 who were less than 85% of ideal body weight [IBW] with anorexia nervosa [AN], 26 who were 90-120% IBW with a history of AN [AN-WR], and 34 who were 90-120% IBW with no eating disorder history [H]). We administered the Eating Disorder Examination-Questionnaire (EDE-Q), Leibowitz Social Anxiety Scale-Self Report (LSAS-SR), Dimensional Assessment of Personality Pathology-Basic Questionnaire (DAPP-BQ; suspiciousness and insecure attachment subscales), and the Toronto Alexithymia Scale (TAS-20). We also analyzed fasting serum oxytocin levels. Most measures of social-emotional functioning showed impairment in women with AN and AN-WR compared to H. Oxytocin levels were low in AN-WR compared to H. Across groups, low oxytocin levels were associated with difficulty identifying feelings (r = -.45, p = .008) and overall alexithymia (r = -.34, p = .0489). We speculate that low oxytocin levels may contribute to alexithymia in women with anorexia nervosa. © 2017 Wiley Periodicals, Inc.

  7. Spray-formed tooling

    NASA Astrophysics Data System (ADS)

    McHugh, K. M.; Key, J. F.

    The United States Council for Automotive Research (USCAR) has formed a partnership with the Idaho National Engineering Laboratory (INEL) to develop a process for the rapid production of low-cost tooling based on spray forming technology developed at the INEL. Phase 1 of the program will involve bench-scale system development, materials characterization, and process optimization. In Phase 2, prototype systems will be designed, constructed, evaluated, and optimized. Process control and other issues that influence commercialization will be addressed during this phase of the project. Technology transfer to USCAR, or a tooling vendor selected by USCAR, will be accomplished during Phase 3. The approach INEL is using to produce tooling, such as plastic injection molds and stamping dies, combines rapid solidification processing and net-shape materials processing into a single step. A bulk liquid metal is pressure-fed into a de Laval spray nozzle transporting a high velocity, high temperature inert gas. The gas jet disintegrates the metal into fine droplets and deposits them onto a tool pattern made from materials such as plastic, wax, clay, ceramics, and metals. The approach is compatible with solid freeform fabrication techniques such as stereolithography, selective laser sintering, and laminated object manufacturing. Heat is extracted rapidly, in-flight, by convection as the spray jet entrains cool inert gas to produce undercooled and semi-solid droplets. At the pattern, the droplets weld together while replicating the shape and surface features of the pattern. Tool formation is rapid; deposition rates in excess of 1 ton/h have been demonstrated for bench-scale nozzles.

  8. LPT. Shield test control building (TAN645), north facade. Camera facing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. Shield test control building (TAN-645), north facade. Camera facing south. Obsolete sign dating from post-1970 program says "Energy and Systems Technology Experimental Facility, INEL." INEEL negative no. HD-40-5-4 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  9. 33. DETAILS OF SAMPLE SUPPORT FRAME ASSEMLBY, LIFTING LUG, AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    33. DETAILS OF SAMPLE SUPPORT FRAME ASSEMLBY, LIFTING LUG, AND SAMPLE CARRIER ROD. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-S-5. INEL INDEX CODE NUMBER: 075 0701 60 851 151979. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  10. Low-level radioactive waste management handbook series: Low-level radioactive waste management in medical and biomedical research institutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1987-03-01

    Development of this handbook began in 1982 at the request of the Radhealth Branch of the California Department of Health Services. California Assembly Bill 1513 directed the DHS to ''evaluate the technical and economic feasibility of (1) reducing the volume, reactivity, and chemical and radioactive hazard of (low-level radioactive) waste and (2) substituting nonradioactive or short-lived radioactive materials for those radionuclides which require long-term isolation from the environment. A contract awarded to the University of California at Irvine-UCI (California Std. Agreement 79902), to develop a document focusing on methods for decreasing low-level radioactive waste (LLW) generation in institutions was amore » result of that directive. In early 1985, the US Department of Energy, through EG and G Idaho, Inc., contracted with UCI to expand, update, and revise the California text for national release.« less

  11. Low oxygen level increases proliferation and metabolic changes in bovine granulosa cells.

    PubMed

    Shiratsuki, Shogo; Hara, Tomotaka; Munakata, Yasuhisa; Shirasuna, Koumei; Kuwayama, Takehito; Iwata, Hisataka

    2016-12-05

    The present study addresses molecular backgrounds underlying low oxygen induced metabolic changes and 1.2-fold change in bovine granulosa cell (GCs) proliferation. RNA-seq revealed that low oxygen (5%) upregulated genes associated with HIF-1 and glycolysis and downregulated genes associated with mitochondrial respiration than that in high oxygen level (21%). Low oxygen level induced high glycolytic activity and low mitochondrial function and biogenesis. Low oxygen level enhanced GC proliferation with high expression levels of HIF-1, VEGF, AKT, mTOR, and S6RP, whereas addition of anti-VEGF antibody decreased cellular proliferation with low phosphorylated AKT and mTOR expression levels. Low oxygen level reduced SIRT1, whereas activation of SIRT1 by resveratrol increased mitochondrial replication and decreased cellular proliferation with reduction of phosphorylated mTOR. These results suggest that low oxygen level stimulates the HIF1-VEGF-AKT-mTOR pathway and up-regulates glycolysis, which contributes to GC proliferation, and downregulation of SIRT1 contributes to hypoxia-associated reduction of mitochondria and cellular proliferation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Guidelines for biosafety laboratory competency: CDC and the Association of Public Health Laboratories.

    PubMed

    Delany, Judy R; Pentella, Michael A; Rodriguez, Joyce A; Shah, Kajari V; Baxley, Karen P; Holmes, David E

    2011-04-15

    These guidelines for biosafety laboratory competency outline the essential skills, knowledge, and abilities required for working with biologic agents at the three highest biosafety levels (BSLs) (levels 2, 3, and 4). The competencies are tiered to a worker's experience at three levels: entry level, midlevel (experienced), and senior level (supervisory or managerial positions). These guidelines were developed on behalf of CDC and the Association of Public Health Laboratories (APHL) by an expert panel comprising 27 experts representing state and federal public health laboratories, private sector clinical and research laboratories, and academic centers. They were then reviewed by approximately 300 practitioners representing the relevant fields. The guidelines are intended for laboratorians working with hazardous biologic agents, obtained from either samples or specimens that are maintained and manipulated in clinical, environmental, public health, academic, and research laboratories.

  13. Obesity And Laboratory Diets Affects Tissue Malondialdehyde (MDA) Levels In Obese Rats

    NASA Astrophysics Data System (ADS)

    Chowdhury, Parimal; Scott, Joseph; Holley, Andy; Hakkak, Reza

    2010-04-01

    This study was conducted to investigate the interaction of obesity and laboratory diets on tissue malondialdehyde levels in rats. Female Zucker obese and lean rats were maintained on either regular grain-based diet or purified casein diet for two weeks, orally gavaged at day 50 with 65 mg/kg DMBA and sacrificed 24 hrs later. Malondialdehyde (MDA) levels were measured in blood and harvested tissues. Data were recorded as mean ± SEM and analyzed statistically. Results show that the obese group on purified casein diet had reduction of MDA levels in the brain, duodenum, liver, lung and kidney tissues as compared to lean group, p <0.05. Obese group on grain-based diet showed significant increase in MDA levels only in the duodenum, p <0.05. We conclude that dietary intervention differentially affects the oxidative markers in obese rats. It appears that purified casein diets were more effective than grain-based diet in reduction of oxidative stress in obese rats.

  14. The Efficacy of Low-Level Continuous Positive Airway Pressure for the Treatment of Snoring

    PubMed Central

    Guzman, Michelle A.; Sgambati, Francis P.; Pho, Huy; Arias, Rafael S.; Hawks, Erin M.; Wolfe, Erica M.; Ötvös, Tamás; Rosenberg, Russell; Dakheel, Riad; Schneider, Hartmut; Kirkness, Jason P.; Smith, Philip L.; Schwartz, Alan R.

    2017-01-01

    Study Objectives: To assess effects of low-level continuous positive airway pressure (CPAP) on snoring in habitual snorers without obstructive sleep apnea (OSA). Methods: A multicenter prospective in-laboratory reversal crossover intervention trial was conducted between September 2013 and August 2014. Habitual snorers were included if they snored (inspiratory sound pressure level ≥ 40 dBA) for ≥ 30% all sleep breaths on a baseline sleep study (Night 1), and if significant OSA and daytime somnolence were absent. Included participants then underwent a CPAP titration study at 2, 4, or 6 cm H2O (Night 2) to examine snoring responses to step-increases in nasal pressure, a treatment night at optimal pressure (Night 3), followed by baseline night (Night 4). At each pressure, snoring intensity was measured on each breath. Snoring frequency was quantified as a percentage of sleep breaths at thresholds of 40, 45, 50, and 55 dBA. Sleep architecture and OSA severity were characterized using standard measurements. Results: On baseline sleep studies, participants demonstrated snoring at ≥ 40 dBA on 53 ± 3% and ≥ 45 dBA on 35 ± 4% of breaths. Snoring frequency decreased progressively as nasal pressure increased from 0 to 4 cm H2O at each threshold, and plateaued thereafter. CPAP decreased snoring frequency by 67% and 85% at 40 and 45 dBA, respectively. Intervention did not alter sleep architecture and sleep apnea decreased minimally. Conclusions: Low-level CPAP below the range required to treat OSA diminished nocturnal snoring, and produced uniform reduction in nightly noise production below the World Health Organization's limit of 45 dBA. Clinical Trial Registration: ClinicalTrials.gov, identifier: NCT01949584. Citation: Guzman MA, Sgambati FP, Pho H, Arias RS, Hawks EM, Wolfe EM, Ötvös T, Rosenberg R, Dakheel R, Schneider H, Kirkness JP, Smith PL, Schwartz AR. The efficacy of low-level continuous positive airway pressure for the treatment of snoring. J Clin Sleep

  15. Energy efficient laboratory fume hood

    DOEpatents

    Feustel, Helmut E.

    2000-01-01

    The present invention provides a low energy consumption fume hood that provides an adequate level of safety while reducing the amount of air exhausted from the hood. A low-flow fume hood in accordance with the present invention works on the principal of providing an air supply, preferably with low turbulence intensity, in the face of the hood. The air flow supplied displaces the volume currently present in the hood's face without significant mixing between the two volumes and with minimum injection of air from either side of the flow. This air flow provides a protective layer of clean air between the contaminated low-flow fume hood work chamber and the laboratory room. Because this protective layer of air will be free of contaminants, even temporary mixing between the air in the face of the fume hood and room air, which may result from short term pressure fluctuations or turbulence in the laboratory, will keep contaminants contained within the hood. Protection of the face of the hood by an air flow with low turbulence intensity in accordance with a preferred embodiment of the present invention largely reduces the need to exhaust large amounts of air from the hood. It has been shown that exhaust air flow reductions of up to 75% are possible without a decrease in the hood's containment performance.

  16. HCC with low- and normal-serum alpha-fetoprotein levels

    PubMed Central

    Carr, Brian I.; Akkiz, Hikmet; Üsküdar, Oguz; Yalçın, Kendal; Guerra, Vito; Kuran, Sedef; Karaoğullarından, Ümit; Altıntaş, Engin; Özakyol, Ayşegül; Tokmak, Salih; Ballı, Tuğsan; Yücesoy, Mehmet; Bahçeci, Halil İbrahim; Ülkü, Abdulalh; Akçam, Tolga; Polat, Kamil Yalçın; Ekinci, Nazım; Şimşek, Halis; Örmeci, Necati; Sonsuz, Abdulalh; Demir, Mehmet; Kılıç, Murat; Uygun, Ahmet; Demir, Ali; Delik, Anıl; Arslan, Burcu; Doran, Figen; Yilmaz, Sezai; Tokat, Yaman

    2018-01-01

    A large database of 1773 HCC patients in Turkey was examined. 41.9% had alpha-fetoprotein (AFP) levels <20 IU/ml and an additional 16.123% had values between 20–100 IU/ml. This 58% of the cohort (<100 IU/ml AFP levels) was examined in detail. 66% of patients with small (<5 cm) HCCs had low AFP, compared to 49% of patients with larger (>5 cm) HCCs. The mean diameter (MTD) of larger MTD, low AFP tumors was 8.4cm. Therefore, factors other than AFP must contribute to HCC tumor growth. Larger tumors in low AFP patients had both higher platelet levels and increased PVT percent. Linear regression analysis for both MTD and multifocality showed that platelet numbers and presence of PVT were significant variables; whereas for PVT, significant variables were albumin, alkaline phosphatase and MTD. Comparisons between patients with AFP levels <20, 20–<100, 100–<1000 and >1000 IU/ml showed the most significant tumor finding was an increase in PVT percent between each group, and to a lesser extent, MTD. Thus, low- or normal-AFP HCCs constitute the majority of patients and have slightly lower MTD and much lower PVT percent than HCCs associated with elevated blood AFP levels. New, non-AFP markers are thus needed, especially for small HCCs PMID:29576865

  17. Cholesterol Level: Can It Be Too Low?

    MedlinePlus

    ... total cholesterol level has been associated with some health problems. Doctors are still trying to find out more about the connection between low cholesterol and health risks. There is no consensus on how to ...

  18. Mississippi State Briefing Book for low-level radioactive waste management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    The Mississippi State Briefing Book is one of a series of state briefing books on low-level radioactive waste management practices. It has been prepared to assist state an federal agency officials in planning for safe low-level radioactive waste disposal. The report contains a profile of low-level radioactive waste generators in Mississippi. The profile is the result of a survey of NRC licensees in Mississippi. The briefing book also contains a comprehensive assessment of low-level radioactive waste management issues and concerns as defined by all major interested parties including industry, government, the media, and interest groups. The assessment was developed throughmore » personal communications with representatives of interested parties, and through a review of media sources. Lastly, the briefing book provides demographic and socioeconomic data and a discussion of relevant government agencies and activities, all of which may impact waste management practices in Mississippi.« less

  19. Wyoming State Briefing Book for low-level radioactive waste management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The Wyoming State Briefing Book is one of a series of state briefing books on low-level radioactive waste management practices. It has been prepared to assist state and federal agency officials in planning for safe low-level radioactive waste disposal. The report contains a profile of low-level radioactive waste generators in Wyoming. The profile is the result of a survey of NRC licensees in Wyoming. The briefing book also contains a comprehensive assessment of low-level radioactive waste management issues and concerns as defined by all major interested parties including industry, government, the media, and interest groups. The assessment was developed throughmore » personal communications with representatives of interested parties, and through a review of media sources. Lastly, the briefing book provides demographic and socioeconomic data and a discussion of relevant government agencies and activities, all of which may impact waste management practices in Wyoming.« less

  20. Massachusetts State Briefing Book for low-level radioactive waste management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-03-12

    The Massachusetts State Briefing Book is one of a series of State briefing books on low-level radioactive waste management practices. It has been prepared to assist State and Federal agency officials in planning for safe low-level radioactive waste disposal. The report contains a profile of low-level radioactive waste generators in Massachusetts. The profile is the result of a survey of NRC licensees in Massachusetts. The briefing book also contains a comprehensive assessment of low-level radioactive waste management issues and concerns as defined by all major interested parties including industry, government, the media, and interest groups. The assessment was developed throughmore » personal communications with representatives of interested parties, and through a review of media sources. Lastly, the briefing book provides demographic and socioeconomic data and a discussion of relevant government agencies and activities, all of which may impact waste management practices in Massachusetts.« less

  1. Texas State Briefing Book for low-level radioactive waste management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-08-01

    The Texas State Briefing Book is one of a series of state briefing books on low-level radioactivee waste management practices. It has been prepared to assist state and federal agency officials in planning for safe low-level radioactive waste disposal. The report contains a profile of low-level radioactive waste generators in Texas. The profile is the result of a survey of NRC licensees in Texas. The briefing book also contains a comprehensive assessment of low-level radioactive waste management issues and concerns as defined by all major interested parties including industry, government, the media, and interest groups. The assessment was developed throughmore » personal communications with representatives of interested parties, and through a review of media sources. Lastly, the briefing book provides demographic and socioeconomic data and a discussion of relevant government agencies and activities, all of which may impact waste management practices in Texas.« less

  2. Ohio State Briefing Book for low-level radioactive waste management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The Ohio State Briefing Book is one of a series of state briefing books on low-level radioactive waste management practices. It has been prepared to assist state and federal agency officials in planning for safe low-level radioactive waste disposal. The report contains a profile of low-level radioactive waste generators in Ohio. The profile is the result of a survey of NRC licensees in Ohio. The briefing book also contains a comprehensive assessment of low-level radioactive waste management issues and concerns as defined by all major interested parties including industry, government, the media, and interest groups. The assessment was developed throughmore » personal communications with representatives of interested parties, and through a review of media sources. Lastly, the briefing book provides demographic and socioeconomic data and a discussion of relevant government agencies and activities, all of which may impact waste management practices in Ohio.« less

  3. Maine State Briefing Book on low-level radioactive waste management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-08-01

    The Maine State Briefing Book is one of a series of state briefing books on low-level radioactive waste management practices. It has been prepared to assist state and Federal agency officials in planning for safe low-level radioactive waste disposal. The report contains a profile of low-level radioactive waste generators in Maine. The profile is the result of a survey of radioactive material licensees in Maine. The briefing book also contains a comprehensive assessment of low-level radioactive waste management issues and concerns as defined by all major interested partices including industry, government, the media, and interest groups. The assessment was developedmore » through personal communications with representatives of interested parties, and through a review of media sources. Lastly, the briefing book provides demographic and socioeconomic data and a discussion of relevant goverment agencies and activities, all of which may impact management practices in Maine.« less

  4. NTP monograph on health effects of low-level lead.

    PubMed

    2012-06-01

    Although reductions in lead (Pb) exposure for the U.S. population have resulted in lower blood Pb levels over time, epidemiological studies continue to provide evidence of health effects at lower and lower blood Pb levels. Low-level Pb was selected for evaluation by the National Toxicology Program (NTP) because of (1) the availability of a large number of epidemiological studies of Pb, (2) a nomination by the National Institute for Occupational Safety and Health for an assessment of Pb at lower levels of exposure, and (3) public concern for effects of Pb in children and adults. This evaluation summarizes the evidence in humans and presents conclusions on health effects in children and adults associated with low-level Pb exposure as indicated by less than 10 micrograms of Pb per deciliter of blood (< 10 microg/dL). The assessment focuses on epidemiological evidence at blood Pb levels < 10 microg/dL and < 5 microg/dL because health effects at higher blood Pb levels are well established. The NTP evaluation was conducted through the Office of Health Assessment and Translation (OHAT, formerly the Center for the Evaluation of Risks to Human Reproduction) and completed in April of 2012. The results of this evaluation are published in the NTP Monograph on Health Effects of Low-Level Lead. The document and appendices are available at http://ntp.niehs.nih.gov/go/evals. This document provides background on Pb exposure and includes a review of the primary epidemiological literature for evidence that low-level Pb is associated with neurological, immunological, cardiovascular, renal, and/or reproductive and developmental effects. The NTP Monograph presents specific conclusions for each health effect area. Overall, the NTP concludes that there is sufficient evidence that blood Pb levels < 10 microg/dL and < 5 microg/dL are associated with adverse health effects in children and adults. This conclusion was based on a review of the primary epidemiological literature, scientific

  5. High-level, but not low-level, motion perception is impaired in patients with schizophrenia.

    PubMed

    Kandil, Farid I; Pedersen, Anya; Wehnes, Jana; Ohrmann, Patricia

    2013-01-01

    Smooth pursuit eye movements are compromised in patients with schizophrenia and their first-degree relatives. Although research has demonstrated that the motor components of smooth pursuit eye movements are intact, motion perception has been shown to be impaired. In particular, studies have consistently revealed deficits in performance on tasks specific to the high-order motion area V5 (middle temporal area, MT) in patients with schizophrenia. In contrast, data from low-level motion detectors in the primary visual cortex (V1) have been inconsistent. To differentiate between low-level and high-level visual motion processing, we applied a temporal-order judgment task for motion events and a motion-defined figure-ground segregation task using patients with schizophrenia and healthy controls. Successful judgments in both tasks rely on the same low-level motion detectors in the V1; however, the first task is further processed in the higher-order motion area MT in the magnocellular (dorsal) pathway, whereas the second task requires subsequent computations in the parvocellular (ventral) pathway in visual area V4 and the inferotemporal cortex (IT). These latter structures are supposed to be intact in schizophrenia. Patients with schizophrenia revealed a significantly impaired temporal resolution on the motion-based temporal-order judgment task but only mild impairment in the motion-based segregation task. These results imply that low-level motion detection in V1 is not, or is only slightly, compromised; furthermore, our data restrain the locus of the well-known deficit in motion detection to areas beyond the primary visual cortex.

  6. Dissociation in the laboratory: a comparison of strategies.

    PubMed

    Leonard, K N; Telch, M J; Harrington, P J

    1999-01-01

    Several methods for inducing dissociation in the laboratory were examined in a sample of 78 undergraduate students. Participants scoring high or low on the Dissociative Experiences Scale participated in three dissociation challenge conditions: (a) dot-staring task, (b) administration of pulsed photic and audio stimulation and (c) stimulus deprivation. Participants recorded their dissociative experiences both before and after each of the three challenge conditions. Across conditions, high DES participants reported significantly more dissociative sensations than low DES participants, even after controlling for pre-challenge dissociation. Moreover, regardless of DES status, pulsed photo and audio stimulation produced the greatest level of dissociative symptoms. The findings suggest that the induction of dissociative symptoms in a nonclinical sample is easily accomplished in the laboratory and that those who report more dissociative symptoms in their day-to-day life exhibit more pronounced dissociative symptoms when undergoing dissociative challenge in the laboratory. Implications for the study and treatment of dissociative symptoms are discussed.

  7. A robust color image fusion for low light level and infrared images

    NASA Astrophysics Data System (ADS)

    Liu, Chao; Zhang, Xiao-hui; Hu, Qing-ping; Chen, Yong-kang

    2016-09-01

    The low light level and infrared color fusion technology has achieved great success in the field of night vision, the technology is designed to make the hot target of fused image pop out with intenser colors, represent the background details with a nearest color appearance to nature, and improve the ability in target discovery, detection and identification. The low light level images have great noise under low illumination, and that the existing color fusion methods are easily to be influenced by low light level channel noise. To be explicit, when the low light level image noise is very large, the quality of the fused image decreases significantly, and even targets in infrared image would be submerged by the noise. This paper proposes an adaptive color night vision technology, the noise evaluation parameters of low light level image is introduced into fusion process, which improve the robustness of the color fusion. The color fuse results are still very good in low-light situations, which shows that this method can effectively improve the quality of low light level and infrared fused image under low illumination conditions.

  8. Final report of the decontamination and decommissioning of the BORAX-V facility turbine building

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arave, A.E.; Rodman, G.R.

    1992-12-01

    The Boiling Water Reactor Experiment (BORAX)-V Facility Turbine Building Decontamination and Decommissioning (D&D) Project is described in this report. The BORAX series of five National Reactor Testing Station (NRTS) reactors pioneered intensive work on boiling water reactor (BWR) experiments conducted between 1953 and 1964. Facility characterization, decision analyses, and D&D plans for the turbine building were prepared from 1979 through 1990. D&D activities of the turbine building systems were initiated in November of 1988 and completed with the demolition and backfill of the concrete foundation in March 1992. Due to the low levels of radioactivity and the absence of loosemore » contamination, the D&D activities were completed with no radiation exposure to the workers. The D&D activities were performed in a manner that no radiological health or safety hazard to the public or to personnel at the Idaho National Engineering Laboratory (INEL) remain.« less

  9. Final report of the decontamination and decommissioning of the BORAX-V facility turbine building

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arave, A.E.; Rodman, G.R.

    1992-12-01

    The Boiling Water Reactor Experiment (BORAX)-V Facility Turbine Building Decontamination and Decommissioning (D D) Project is described in this report. The BORAX series of five National Reactor Testing Station (NRTS) reactors pioneered intensive work on boiling water reactor (BWR) experiments conducted between 1953 and 1964. Facility characterization, decision analyses, and D D plans for the turbine building were prepared from 1979 through 1990. D D activities of the turbine building systems were initiated in November of 1988 and completed with the demolition and backfill of the concrete foundation in March 1992. Due to the low levels of radioactivity and themore » absence of loose contamination, the D D activities were completed with no radiation exposure to the workers. The D D activities were performed in a manner that no radiological health or safety hazard to the public or to personnel at the Idaho National Engineering Laboratory (INEL) remain.« less

  10. Effect of nitrate concentration on filamentous bulking under low level of dissolved oxygen in an airlift inner circular anoxic-aerobic incorporate reactor.

    PubMed

    Su, Yiming; Zhang, Yalei; Zhou, Xuefei; Jiang, Ming

    2013-09-01

    This laboratory research investigated a possible cause of filamentous bulking under low level of dissolved oxygen conditions (dissolved oxygen value in aerobic zone maintained between 0.6-0.8 mg O2/L) in an airlift inner-circular anoxic-aerobic reactor. During the operating period, it was observed that low nitrate concentrations affected sludge volume index significantly. Unlike the existing hypothesis, the batch tests indicated that filamentous bacteria (mainly Thiothrix sp.) could store nitrate temporarily under carbon restricted conditions. When nitrate concentration was below 4 mg/L, low levels of carbon substrates and dissolved oxygen in the aerobic zone stimulated the nitrate-storing capacity of filaments. When filamentous bacteria riched in nitrate reached the anoxic zone, where they were exposed to high levels of carbon but limited nitrate, they underwent denitrification. However, when nonfilamentous bacteria were exposed to similar conditions, denitrification was restrained due to their intrinsic nitrate limitation. Hence, in order to avoid filamentous bulking, the nitrate concentration in the return sludge (from aerobic zone to the anoxic zone) should be above 4 mg/L, or alternatively, the nitrate load in the anoxic zone should be kept at levels above 2.7 mg NO(3-)-N/g SS.

  11. Optimization of low-level LS counter Quantulus 1220 for tritium determination in water samples

    NASA Astrophysics Data System (ADS)

    Jakonić, Ivana; Todorović, Natasa; Nikolov, Jovana; Bronić, Ines Krajcar; Tenjović, Branislava; Vesković, Miroslav

    2014-05-01

    Liquid scintillation counting (LSC) is the most commonly used technique for measuring tritium. To optimize tritium analysis in waters by ultra-low background liquid scintillation spectrometer Quantulus 1220 the optimization of sample/scintillant ratio, choice of appropriate scintillation cocktail and comparison of their efficiency, background and minimal detectable activity (MDA), the effect of chemi- and photoluminescence and combination of scintillant/vial were performed. ASTM D4107-08 (2006) method had been successfully applied in our laboratory for two years. During our last preparation of samples a serious quench effect in count rates of samples that could be consequence of possible contamination by DMSO was noticed. The goal of this paper is to demonstrate development of new direct method in our laboratory proposed by Pujol and Sanchez-Cabeza (1999), which turned out to be faster and simpler than ASTM method while we are dealing with problem of neutralization of DMSO in apparatus. The minimum detectable activity achieved was 2.0 Bq l-1 for a total counting time of 300 min. In order to test the optimization of system for this method tritium level was determined in Danube river samples and also for several samples within intercomparison with Ruđer Bošković Institute (IRB).

  12. 4. CONSTRUCTION PROGRESS VIEW OF EQUIPMENT IN FRONT PART OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. CONSTRUCTION PROGRESS VIEW OF EQUIPMENT IN FRONT PART OF CONTROL BUNKER (TRANSFORMER, HYDRAULIC TANK, PUMP, MOTOR). SHOWS UNLINED CORRUGATED METAL WALL. CAMERA FACING EAST. INEL PHOTO NUMBER 65-5433, TAKEN OCTOBER 20, 1965. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  13. 29. PLAN OF THE ARVFS FIELD TEST FACILITY SHOWING BUNKER, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    29. PLAN OF THE ARVFS FIELD TEST FACILITY SHOWING BUNKER, CABLE CHASE, SHIELDING TANK AND FRAME ASSEMBLY. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-1. INEL INDEX CODE NUMBER: 075 0701 851 151970. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  14. Comparative performance evaluation of advanced AC and DC EV propulsion systems

    NASA Astrophysics Data System (ADS)

    MacDowall, R. D.; Crumley, R. L.

    Idaho National Engineering Laboratory (INEL) evaluates EV propulsion systems and components for the U.S. Department of Energy (DOE) Electric and Hybrid Vehicle (EHV) Program. In this study, experimental data were used to evaluate the relative performances of the benchmark Chrysler/GE ETV-1 DC and the Ford/GE First Generation Single-Shaft AC (ETX-I) propulsion systems. Tests were conducted on the INEL's chassis dynamometer using identical aerodynamic and rolling resistance road-load coefficients and vehicle test weights. The results allowed a direct comparison of selected efficiency and performance characteristics for the two propulsion system technologies. The ETX-I AC system exhibited slightly lower system efficiency during constant speed testing than the ETV-1 DC propulsion system.

  15. Kansas State Briefing Book on low-level radioactive waste management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-07-01

    The Kansas State Briefing Book is one of a series of state briefing books on low-level radioactive waste management practices. It has been prepared to assist state and federal agency officials in planning for safe low-level radioactive waste disposal. The report contains a profile of low-level radioactive waste generators in Kansas. The profile is the result of a survey of radioactive material licensees in Kansas. The briefing book also contains a comprehensive assessment of low-level radioactive waste management issues and concerns as defined by all major interested parties including industry, government, the media, and interest groups. The assessment was developedmore » through personal communications with representatives of interested parties, and through a review of media sources. Lastly, the briefing book provides demographic and socioeconomic data and a discussion of relevant government agencies and activities, all of which may affect waste management practices in Kansas.« less

  16. Vermont State Briefing Book on low-level radioactive waste management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-07-01

    The Vermont State Briefing Book is one of a series of state briefing books on low-level radioactive waste management practices. It has been prepared to assist state and federal agency officials in planning for safe low-level radioactive waste disposal. The report contains a profile of low-level radioactive waste generators in Vermont. The profile is the result of a survey of Nuclear Regulatory Commission licensees in Vermont. The briefing book also contains a comprehensive assessment of low-level radioactive waste management issues and concerns as defined by all major interested parties including industry, government, the media, and interest groups. The assessment wasmore » developed through personal communications with representatives of interested parties, and through a review of media sources. Lastly, the briefing book provides demographic and socioeconomic data and a discussion of relevant government agencies and activities, all of which may affect waste management practices in Vermont.« less

  17. Geology, geochronology, and potential volcanic hazards in the Lava Ridge-Hells Half Acre area, eastern Snake River Plain, Idaho

    USGS Publications Warehouse

    Kuntz, Mel A.; Dalrymple, G. Brent

    1979-01-01

    The evaluation of volcanic hazards for the proposed Safety Test Reactor Facility (STF) at the Argonne National Laboratory-West (ANLW) site, Idaho National Engineering Laboratory (INEL), Idaho, involves an analysis of the geology of the Lava Ridge-Hells Half Acre area and of K-At age determinations on lava flows in cored drill holes. The ANLW site at INEL lies in a shallow topographic depression bounded on the east and south by volcanic rift zones that are the locus of past shield-type basalt volcanism and by rhyolite domes erupted along the ring fracture of an inferred rhyolite caldera. The K-At age data indicate that the ANLW site has been flooded by basalt lava flows at irregular intervals from perhaps a few thousand years to as much as 300,000-400,000 years, with an average recurrence interval between flows of approximately 80,000-100,000 years. At least five major lava flows have covered the ANLW site within the past 500,000 years.

  18. Making a Low-Cost Soda Can Ethanol Burner for Out-of-Laboratory Flame Test Demonstrations and Experiments

    ERIC Educational Resources Information Center

    Yu, Henson L. Lee; Domingo, Perfecto N., Jr.; Yanza, Elliard Roswell S.; Guidote, Armando M., Jr.

    2015-01-01

    This article demonstrates how to make a low-cost ethanol burner utilizing soda cans. It burns with a light blue flame suitable for out-of-laboratory flame test demonstrations where interference from a yellow flame needs to be avoided.

  19. Laboratory medicine in France. A jeopardized situation.

    PubMed

    Valdiguié, P M; de Graeve, J S; Guerre, J P

    1997-11-06

    The expenses for health care in France have risen considerably during the present decade, ranking third after USA and Canada in the Western world. In spite of the very low cost of laboratory medicine (2.4% of the total expenditure in 1995), clinical laboratories have undergone a severe squeeze, due to two limiting factors; a decrease in the ordering of laboratory tests from private physicians and a reduction in the total expenses for laboratory services from the Social Security. Consequently, there has been unemployment of technical and secretarial staff and severe restriction in investment for buying new equipment. However, hospital laboratories will manage to assume their challenge in developing robotics, automation, molecular pathology techniques and expert systems. Private laboratories, in spite of their efforts to follow the technological advances in automation, will survive thanks to consolidation of regional networks that operate in a cooperative rather than competitive mode. Therefore, the challenge will be not in the adaptation of clinical laboratories, but in the limitation of overspending at the national level and in modification of the behaviour of irresponsible citizens accustomed to spending freely on health care services.

  20. Effects of Varenicline Alone and in Combination With Low-dose Naltrexone on Alcohol-primed Smoking in Heavy-drinking Tobacco Users: A Preliminary Laboratory Study.

    PubMed

    Roberts, Walter; Shi, Julia M; Tetrault, Jeanette M; McKee, Sherry A

    Heavy-drinking tobacco users are less likely to successfully quit smoking than their moderate-drinking counterparts, even when they are prescribed smoking cessation medication. One strategy for improving treatment outcomes in this subgroup of tobacco users may be to combine medication therapies to target both alcohol and tobacco use simultaneously. Adding naltrexone to frontline smoking cessation treatments may improve treatment outcomes in this group. This double-blind, placebo-controlled human laboratory study examined the effects of varenicline (2 mg/d) and varenicline (2 mg/d), combined with a low dose of naltrexone (25 mg/d) on alcohol-primed smoking behavior in a laboratory model of smoking relapse in heavy-drinking tobacco users (n = 30). Participants attended a laboratory session and received an alcohol challenge (target breath alcohol concentration = 0.030 g/dL). They completed a smoking delay task that assessed their ability to resist smoking followed by an ad libitum smoking phase (primary outcomes). They also provided ratings of subjective drug effects and craving, and carbon monoxide levels were measured after smoking (secondary outcomes). Participants receiving varenicline monotherapy delayed smoking longer and smoked fewer cigarettes than those on placebo. Participants receiving varenicline + low-dose naltrexone did not delay smoking longer than those receiving varenicline alone. Participants in both active medication arms smoked fewer cigarettes ad libitum than those receiving placebo. Varenicline can improve smoking outcomes even after an alcohol prime, supporting its use in heavy drinkers who wish to quit smoking. Findings did not support increased efficacy of combined varenicline + low-dose naltrexone relative to varenicline monotherapy.

  1. Monitoring of Low-Level Virus in Natural Waters

    PubMed Central

    Sorber, Charles A.; Sagik, Bernard P.; Malina, Joseph F.

    1971-01-01

    The insoluble polyelectrolyte technique for concentrating virus is extended to extremely low virus levels. The effectiveness of this method employing a coliphage T2 model is a constant 20% over a range of virus levels from 103 to 10−4 plaque-forming units/ml. The efficiency of the method is dependent upon pH control during the concentration phase. Although the study was initiated to develop a method for quantitating the effectiveness of water and wastewater treatment methods for the removal of viruses from waters at low concentrations, the potential of the technique for efficient monitoring of natural waters is apparent. PMID:4940873

  2. Low-level nocturnal wind maximum over the Central Amazon Basin

    NASA Technical Reports Server (NTRS)

    Greco, Steven; Ulanski, Stanley; Garstang, Michael; Houston, Samuel

    1992-01-01

    A low-level nocturnal wind maximum is shown to exist over extensive and nearly undisturbed rainforest near the central Amazon city of Manaus. Meteorological data indicate the presence of this nocturnal wind maximum during both the wet and dry seasons of the Central Amazon Basin. Daytime wind speeds which are characteristically 3-7 m/s between 300 and 1000 m increase to 10-15 m/s shortly after sunset. The wind-speed maximum is reached in the early evening, with wind speeds remaining high until several hours after sunrise. The nocturnal wind maximum is closely linked to a strong low-level inversion formed by radiational cooling of the rainforest canopy. Surface and low-level pressure gradients between the undisturbed forest and the large Amazon river system and the city of Manaus are shown to be responsible for much of the nocturnal wind increase. The pressure gradients are interpreted as a function of the thermal differences between undisturbed forest and the river/city. The importance of both the frictional decoupling and the horizontal pressure gradient suggest that the nocturnal wind maximum does not occur uniformly over all Amazonia. Low-level winds are thought to be pervasive under clear skies and strong surface cooling and that, in many places (i.e., near rivers), local pressure gradients enhance the low-level nocturnal winds.

  3. Central nervous system transplantation benefited by low-level laser irradiation

    NASA Astrophysics Data System (ADS)

    Rochkind, S.; Lubart, Rachel; Wollman, Yoram; Simantov, Rabi; Nissan, Moshe; Barr-Nea, Lilian

    1990-06-01

    Effect of low-level laser irradiation on the central nervous system transplantation is reported. Ernbryonal brain allografts were transplanted into the brain of 20 adult rats and peripheral nerve graft transplanted into the severely injured spinal cord of 16 dogs. The operated wound of 10 rats and 8 dogs were exposed daily for 21 days to lowpower laser irradiation CW HeNe laser (35 mW, 632.8 run, energy density of 30 J/cm2 at each point for rats and 70 J/cm2 at each point for dogs). This study shows that (i) the low-level laser irradiation prevents extensive glial scar formation (a limiting factor in CNS regeneration) between embryonal transplants and host brain; (ii) Dogs made paraplegic by spinal cord injury were able to walk 3-6 months later. Recovery of these dogs was effected by the implantation of a fragment of autologous sciatic nerve at the site of injury and subsequently exposing the dogs to low-level laser irradiation. The effect of laser irradiation on the embryonal nerve cells grown in tissue culture was also observed. We found that low-level laser irradiation induced intensive migration of neurites outward of the aggregates 15-22 The results of the present study and our previous investigations suggest that low-level laser irradiation is a novel tool for treatment of peripheral and central nervous system injuries.

  4. Formation of nocturnal low-level jets and structure of the nocturnal boundary layer in the Southern Great Plains

    NASA Astrophysics Data System (ADS)

    Klein, P. M.; Bonin, T. A.; Newman, J. F.; Wainwright, C. E.; Blumberg, W. G.; Turner, D. D.; Chilson, P. B.; Wharton, S.

    2014-12-01

    The Lower Atmospheric Boundary Layer Experiment (LABLE) included two measurement campaigns at the Atmospheric Radiation Measurement (ARM) Southern Great Plains site in Oklahoma in 2012 and 2013. Its main objective was to study turbulent phenomena in the lowest 2-km of the atmosphere using a variety of novel atmospheric profiling techniques including a sodar, multiple Doppler wind lidars (DWL), a Raman lidar and an atmospheric emitted radiance interferometer (AERI). Several instruments from the University of Oklahoma and Lawrence Livermore National Laboratory were deployed to augment the suite of in-situ and remote sensing instruments at the ARM site. The complementary nature of the deployed instruments with respect to resolution and height coverage provides for a near-complete picture of the dynamic and thermodynamic structure of the atmospheric boundary layer. LABLE can be considered unique in that it was designed as a multi-phase, low-cost, and multi-agency collaboration. Graduate students served as principal investigators who took the lead in designing and conducting experiments aimed at examining boundary-layer processes. This presentation provides an overview of the LABLE experiments and a summary of important results. One focus area will be the dynamic and thermodynamic structure of the nocturnal boundary layer and the formation of nocturnal low-level jets. Such low-level jets were frequently observed during both LABLE campaigns and often interacted with mesoscale atmospheric disturbances such as frontal passages. The combination of high-resolution AERI temperature profiles with DWL mean wind and turbulence profiles provided new insights about the structure and evolution of low-level jets.

  5. Low-level laser effects on bacterial cultures submitted to heat stress

    NASA Astrophysics Data System (ADS)

    Gonçalves, E. M.; Guimarães, O. R.; Geller, M.; Paoli, F.; Fonseca, A. S.

    2016-06-01

    Low-level lasers have been used worldwide to treat a number of diseases, pain relief, and wound healing. Some studies demonstrated that low-level laser radiations induce effects depending on the physiological state and DNA repair mechanisms of cells. In this work we evaluated the effects of low-level red and infrared lasers on Escherichia coli cells deficient in SOS responses submitted to heat stress. Exponential and stationary E. coli cultures of wild type (AB1157), RecA deficient (AB2463) and LexA deficient (AB2494), both SOS response deficient, were exposed to low-level red and infrared lasers at different fluences and submitted to heat stress (42 °C, 20 min). After that, cell survival and morphology were evaluated. Previous exposure to red, but not infrared lasers, increases survival fractions and decreases the area ratios of E. coli AB1157 cells submitted to heat stress. Our research suggests that a low-level red laser increases cell viability and protects cells from morphological alteration in E. coli cultures submitted to heat stress depending on laser wavelength and SOS response.

  6. A Low Cost Microcomputer Laboratory for Investigating Computer Architecture.

    ERIC Educational Resources Information Center

    Mitchell, Eugene E., Ed.

    1980-01-01

    Described is a microcomputer laboratory at the United States Military Academy at West Point, New York, which provides easy access to non-volatile memory and a single input/output file system for 16 microcomputer laboratory positions. A microcomputer network that has a centralized data base is implemented using the concepts of computer network…

  7. 31. SECTIONS AND DETAILS OF ARVFS FACILITY, INCLUDING RADIATION HAZARD ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    31. SECTIONS AND DETAILS OF ARVFS FACILITY, INCLUDING RADIATION HAZARD SIGN, WOOD RETAINING WALL, TANK COVER, AND DRAIN BOX. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-3. INEL INDEX CODE NUMBER: 075 0701 851 151972. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  8. 32. ISOMETRIC VIEW OF PIPING PLAN, SHOWING PATH OF CONDUIT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    32. ISOMETRIC VIEW OF PIPING PLAN, SHOWING PATH OF CONDUIT FROM CONTROL BUNKER TO SHIELDING TANK. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-P-1. INEL INDEX CODE NUMBER: 075 0701 60 851 151977. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  9. Space Shuttle Main Engine Off-Nominal Low Power Level Operation

    NASA Technical Reports Server (NTRS)

    Bradley, Michael

    1997-01-01

    This paper describes Rocketdyne's successful analysis and demonstration of the Space Shuttle Main Engine (SSME) operation at off-nominal power levels during Reusable Launch Vehicle (RLV) evaluation tests. The nominal power level range for the SSME is from 65% rated power level (RPL) to 109% RPL. Off-nominal power levels incrementally demonstrated were: 17% RPL, 22% RPL, 27% RPL, 40% RPL, 45% RPL, and 50% RPL. Additional achievements during low power operation included: use of a hydrostatic bearing High Pressure Oxidizer Turbopump (HPOTP), nominal High Pressure Fuel Turbopump (HPFTP) first rotor critical speed operation, combustion stability at low power levels, and refined definition of nozzle flow separation heat loads.

  10. Infrared low-level wind shear work

    NASA Technical Reports Server (NTRS)

    Adamson, Pat

    1988-01-01

    Results of field experiments for the detection of clear air disturbance and low level wind shear utilizing an infrared airborne system are given in vugraph form. The hits, misses and nuisance alarms scores are given. Information is given on the infrared spatial resolution technique. The popular index of aircraft hazard (F= WX over g - VN over AS) is developed for a remote temperature sensor.

  11. DNA damage in blood cells exposed to low-level lasers.

    PubMed

    Sergio, Luiz Philippe da Silva; Silva, Ana Paula Almeida da; Amorim, Philipi Freitas; Campos, Vera Maria Araújo; Magalhães, Luis Alexandre Gonçalves; de Paoli, Flavia; de Souza da Fonseca, Adenilson

    2015-04-01

    In regenerative medicine, there are increasing applications of low-level lasers in therapeutic protocols for treatment of diseases in soft and in bone tissues. However, there are doubts about effects on DNA, and an adequate dosimetry could improve the safety of clinical applications of these lasers. This work aimed to evaluate DNA damage in peripheral blood cells of Wistar rats induced by low-level red and infrared lasers at different fluences, powers, and emission modes according to therapeutic protocols. Peripheral blood samples were exposed to lasers and DNA damage was accessed by comet assay. In other experiments, DNA damage was accessed in blood cells by modified comet assay using formamidopyrimidine DNA glycosylase (Fpg) and endonuclease III enzymes. Data show that exposure to low-level red and infrared lasers induce DNA damage depending on fluence, power and emission mode, which are targeted by Fpg and endonuclease III. Oxidative DNA damage should be considered for therapeutic efficacy and patient safety in clinical applications based on low-level red and infrared lasers. © 2015 Wiley Periodicals, Inc.

  12. Quality-assurance results for routine water analyses in U.S. Geological Survey laboratories, water year 1998

    USGS Publications Warehouse

    Ludtke, Amy S.; Woodworth, Mark T.; Marsh, Philip S.

    2000-01-01

    The U.S. Geological Survey operates a quality-assurance program based on the analyses of reference samples for two laboratories: the National Water Quality Laboratory and the Quality of Water Service Unit. Reference samples that contain selected inorganic, nutrient, and low-level constituents are prepared and submitted to the laboratory as disguised routine samples. The program goal is to estimate precision and bias for as many analytical methods offered by the participating laboratories as possible. Blind reference samples typically are submitted at a rate of 2 to 5 percent of the annual environmental-sample load for each constituent. The samples are distributed to the laboratories throughout the year. The reference samples are subject to the identical laboratory handling, processing, and analytical procedures as those applied to environmental samples and, therefore, have been used as an independent source to verify bias and precision of laboratory analytical methods and ambient water-quality measurements. The results are stored permanently in the National Water Information System and the Blind Sample Project's data base. During water year 1998, 95 analytical procedures were evaluated at the National Water Quality Laboratory and 63 analytical procedures were evaluated at the Quality of Water Service Unit. An overall evaluation of the inorganic and low-level constituent data for water year 1998 indicated 77 of 78 analytical procedures at the National Water Quality Laboratory met the criteria for precision. Silver (dissolved, inductively coupled plasma-mass spectrometry) was determined to be imprecise. Five of 78 analytical procedures showed bias throughout the range of reference samples: chromium (dissolved, inductively coupled plasma-atomic emission spectrometry), dissolved solids (dissolved, gravimetric), lithium (dissolved, inductively coupled plasma-atomic emission spectrometry), silver (dissolved, inductively coupled plasma-mass spectrometry), and zinc

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stevens, S.E. Jr.; Chung, K.T.

    Anaerobic bacteria were isolated from deep subsurface sediment samples taken at study sites in Idaho (INEL) and Washington (HR) by culturing on dilute and concentrated medium. Morphologically distinct colonies were purified, and their responses to 21 selected physiological tests were determined. Although the number of isolates was small (18 INEL, 27 HR) some general patterns could be determined. Most strains could utilize all the carbon sources, however the glycerol and melizitose utilization was positive for 50% or less of the HR isolates. Catalase activity (27.78% at INEL, 74.07% at HR) and tryptophan metabolism (11.12% at INEL, 40.74% at HR) weremore » significantly different between the two study sites. MPN and viable counts indicate that sediments near the water table yield the greatest numbers of anaerobes. Deeper sediments also appear to be more selective with the greatest number of viable counts on low-nutrient mediums. Likewise, only strictly obligate anaerobes were found in the deepest sediment samples. Selective media indicated the presence of methanogens, acetogens, and sulfate reducers at only the HR site.« less

  14. Marine plankton as an indicator of low-level radionuclide contamination in the Southern Ocean

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marsh, K.V.; Buddemeier, R.W.

    1984-07-01

    We have initiated an investigation of the utility of marine plankton as bioconcentrating samplers of low-level marine radioactivity in the southern hemisphere. A literature review shows that both freshwater and marine plankton have trace element and radionuclide concentration factors (relative to water) of up to 10/sup 4/. In the years 1956-1958, considerable work was done on the accumulation and distribution of a variety of fission and activation products produced by the nuclear tests in the Marshall Islands. Since then, studies have largely been confined to a few selected radionuclides, and by far most of this work has been done inmore » the northern hemisphere. We participated in Operation Deepfreeze 1981, collecting 32 plankton samples from the U.S. Coast Guard Cutter Glacier on its Antarctic cruise, while Battelle Pacific Northwest Laboratories concurrently sampled air, water, rain and fallout. We were able to measure concentrations of the naturally occurring radionuclides /sup 7/Be, /sup 40/K and the U and th series, and we believe that we have detected low levels of /sup 144/Ce and /sup 95/Nb in seven samples ranging as far south as 68/sup 0/. There is a definite association between the radionuclide content of plankton and air filters, suggesting that aerosol resuspension of marine radioactivity may be occurring. Biological identification of the plankton suggests a possible correlation between radionuclide concentration and foraminifera content of the samples. 38 references, 7 figures, 3 tables.« less

  15. Meticulous plasma isolation is essential to avoid false low-level viraemia in Roche Cobas HIV-1 viral load assays.

    PubMed

    Mortier, Virginie; Vancoillie, Leen; Dauwe, Kenny; Staelens, Delfien; Demecheleer, Els; Schauvliege, Marlies; Dinakis, Sylvie; Van Maerken, Tom; Dessilly, Géraldine; Ruelle, Jean; Verhofstede, Chris

    2017-10-24

    Pre-analytical sample processing is often overlooked as a potential cause of inaccurate assay results. Here we demonstrate how plasma, extracted from standard EDTA-containing blood collection tubes, may contain traces of blood cells consequently resulting in a false low-level HIV-1 viral load when using Roche Cobas HIV-1 assays. The presence of human DNA in Roche Cobas 4800 RNA extracts and in RNA extracts from the Abbott HIV-1 RealTime assay was assessed by quantifying the human albumin gene by means of quantitative PCR. RNA was extracted from plasma samples before and after an additional centrifugation and tested for viral load and DNA contamination. The relation between total DNA content and viral load was defined. Elevated concentrations of genomic DNA were detected in 28 out of 100 Cobas 4800 extracts and were significantly more frequent in samples processed outside of the AIDS Reference Laboratory. An association between genomic DNA presence and spurious low-level viraemia results was demonstrated. Supplementary centrifugation of plasma before RNA extraction eliminated the contamination and the false viraemia. Plasma isolated from standard EDTA-containing blood collection tubes may contain traces of HIV DNA leading to false viral load results above the clinical cutoff. Supplementary centrifugation of plasma before viral load analysis may eliminate the occurrence of this spurious low-level viraemia.

  16. The Advanced Labs Website: resources for upper-level laboratories

    NASA Astrophysics Data System (ADS)

    Torres-Isea, Ramon

    2012-03-01

    The Advanced Labs web resource collection is an effort to create a central, comprehensive information base for college/university faculty who teach upper-level undergraduate laboratories. The website is produced by the American Association of Physics Teachers (AAPT). It is a part of ComPADRE, the online collection of resources in physics and astronomy education, which itself is a part of the National Science Foundation-funded National Science Digital Library (NSDL). After a brief review of its history, we will discuss the current status of the website while describing the various types of resources available at the site and presenting examples of each. We will detail a step-by-step procedure for submitting resources to the website. The resource collection is designed to be a community effort and thus welcomes input and contributions from its users. We will also present plans, and will seek audience feedback, for additional website services and features. The constraints, roadblocks, and rewards of this project will also be addressed.

  17. Providing critical laboratory results on time, every time to help reduce emergency department length of stay: how our laboratory achieved a Six Sigma level of performance.

    PubMed

    Blick, Kenneth E

    2013-08-01

    To develop a fully automated core laboratory, handling samples on a "first in, first out" real-time basis with Lean/Six Sigma management tools. Our primary goal was to provide services to critical care areas, eliminating turnaround time outlier percentage (TAT-OP) as a factor in patient length of stay (LOS). A secondary goal was to achieve a better laboratory return on investment. In 2011, we reached our primary goal when we calculated the TAT-OP distribution and found we had achieved a Six Sigma level of performance, ensuring that our laboratory service can be essentially eliminated as a factor in emergency department patient LOS. We also measured return on investment, showing a productivity improvement of 35%, keeping pace with our increased testing volume. As a result of our Lean process improvements and Six Sigma initiatives, in part through (1) strategic deployment of point-of-care testing and (2) core laboratory total automation with robotics, middleware, and expert system technology, physicians and nurses at the Oklahoma University Medical Center can more effectively deliver lifesaving health care using evidence-based protocols that depend heavily on "on time, every time" laboratory services.

  18. Laboratory Evaluation of Expedient Low-Temperature Concrete Admixtures for Repairing Blast Holes in Cold Weather

    DTIC Science & Technology

    2013-01-08

    This re- search ignores effects on long-term durability, trafficability, temperature rebar corrosion , and other concerns that are of minimal... concrete because it can cause corrosion of steel reinforcement. However, the corrosion problem develops slowly with time; therefore, this problem has a...ER D C/ CR RE L TR -1 3- 1 Laboratory Evaluation of Expedient Low- Temperature Concrete Admixtures for Repairing Blast Holes in Cold

  19. Psilocybin impairs high-level but not low-level motion perception.

    PubMed

    Carter, Olivia L; Pettigrew, John D; Burr, David C; Alais, David; Hasler, Felix; Vollenweider, Franz X

    2004-08-26

    The hallucinogenic serotonin(1A&2A) agonist psilocybin is known for its ability to induce illusions of motion in otherwise stationary objects or textured surfaces. This study investigated the effect of psilocybin on local and global motion processing in nine human volunteers. Using a forced choice direction of motion discrimination task we show that psilocybin selectively impairs coherence sensitivity for random dot patterns, likely mediated by high-level global motion detectors, but not contrast sensitivity for drifting gratings, believed to be mediated by low-level detectors. These results are in line with those observed within schizophrenic populations and are discussed in respect to the proposition that psilocybin may provide a model to investigate clinical psychosis and the pharmacological underpinnings of visual perception in normal populations.

  20. Simulating Roll Clouds associated with Low-Level Convergence.

    NASA Astrophysics Data System (ADS)

    Prasad, A. A.; Sherwood, S. C.

    2015-12-01

    Convective initiation often takes place when features such as fronts and/or rolls collide, merge or otherwise meet. Rolls indicate boundary layer convergence and may initiate thunderstorms. These are often seen in satellite and radar imagery prior to the onset of deep convection. However, links between convergence driven rolls and convection are poor in global models. The poor representation of convection is the source of many model biases, especially over the Maritime Continent in the Tropics. We simulate low-level convergence lines over north-eastern Australia using the Weather Research and Forecasting (WRF) Model (version 3.7). The simulations are events from September-October 2002 driven by sea breeze circulations. Cloud lines associated with bore-waves that form along the low-level convergence lines are thoroughly investigated in this study with comparisons from satellite and surface observations. Initial simulations for a series of cloud lines observed on 4th October, 2002 over the Gulf of Carpentaria showed greater agreement in the timing and propagation of the disturbance and the low-level convergence, however the cloud lines or streets of roll clouds were not properly captured by the model. Results from a number of WRF simulations with different microphysics, cumulus and planetary boundary layer schemes, resolution and boundary conditions will also be discussed.

  1. Science laboratory behavior strategies of students relative to performance in and attitude to laboratory work

    NASA Astrophysics Data System (ADS)

    Okebukola, Peter Akinsola

    The relationship between science laboratory behavior strategies of students and performance in and attitude to laboratory work was investigated in an observational study of 160 laboratory sessions involving 600 class five (eleventh grade) biology students. Zero-order correlations between the behavior strategies and outcome measures reveal a set of low to strong relationships. Transmitting information, listening and nonlesson related behaviors exhibited low correlations with practical skills and the attitude measure. The correlations between manipulating apparatus and observation with practical skills measures were found to be strong. Multiple correlation analysis revealed that the behaviors of students in the laboratories observed accounted for a large percentage of the variance in the scores on manipulative skills and a low percentage on interpretation of data, responsibility, initiative, and work habits. One significant canonical correlation emerged. The loadings on this canonical variate indicate that the practical skills measures, i.e., planning and design, manipulative skills and conduct of experiments, observation and recording of data, and attitude to laboratory work made primary contributions to the canonical relationship. Suggestions as to how students can be encouraged to go beyond cookbook-like laboratories and develop a more favorable attitude to laboratory work are made.

  2. Common Graphics Library (CGL). Volume 2: Low-level user's guide

    NASA Technical Reports Server (NTRS)

    Taylor, Nancy L.; Hammond, Dana P.; Theophilos, Pauline M.

    1989-01-01

    The intent is to instruct the users of the Low-Level routines of the Common Graphics Library (CGL). The Low-Level routines form an application-independent graphics package enabling the user community to construct and design scientific charts conforming to the publication and/or viewgraph process. The Low-Level routines allow the user to design unique or unusual report-quality charts from a set of graphics utilities. The features of these routines can be used stand-alone or in conjunction with other packages to enhance or augment their capabilities. This library is written in ANSI FORTRAN 77, and currently uses a CORE-based underlying graphics package, and is therefore machine-independent, providing support for centralized and/or distributed computer systems.

  3. Report on a study of fires with smoke gas development : determination of blood cyanide levels, clinical signs and laboratory values in victims.

    PubMed

    Geldner, G; Koch, E M; Gottwald-Hostalek, U; Baud, F; Burillo, G; Fauville, J-P; Levi, F; Locatelli, C; Zilker, T

    2013-08-01

    This is a report on an international non-interventional study of patients exposed to fires with smoke development in closed rooms. The objective of the study was to document clinical symptoms, relevant laboratory values and blood cyanide concentrations from fire victims in order to confirm or rule out presumptive correlations between the individual parameters. The study was conducted in five European countries with patients being included if they presented with the characteristic clinical signs, such as soot deposits and altered neurological status. Venous blood samples were taken from victims prior to administration of an antidote in all cases and determination of cyanide concentration was performed in a central laboratory using high performance liquid chromatography. Data from 102 patients (62 % male, average age 49 years) were included in the evaluation with no blood samples being available for analysis from 2 patients. In 25 patients the blood cyanide concentration was below the limit of detection of 1.2 μmol/l. Cyanide levels between 1.2 and 10 μmol/l were measured in 54 patients, 7 patients had values between 10 and 20 μmol/l, 4 patients between 20 and 40 μmol/l while levels above 40 μmol/l were determined in 10 patients. The results of the study could not demonstrate that the cyanide level was influenced either by the interval between smoke exposure and blood sampling or the duration presence at the fire scene. The following clinical signs or laboratory values were recorded as relevant for increased and possibly toxic cyanide levels: respiratory arrest, dyspnea, resuscitation requirement, tracheal intubation, respiratory support measures, low Glasgow coma scale (GCS) score and respiratory frequency. A correlation between cyanide concentration and the total amount of soot deposits on the face and neck, in the oral cavity and in expectoration was confirmed. A correlation between cyanide and carboxyhemoglobin (COHb) levels in the blood of fire victims was

  4. Contextual Influences on Concordance between Maternal Report and Laboratory Observation of Toddler Fear

    PubMed Central

    Kiel, Elizabeth J.; Hummel, Alexandra C.

    2016-01-01

    Emotion and temperament researchers have faced an enduring issue of how to best measure children’s tendencies to express specific emotions. Inconsistencies between laboratory observation and parental report have made it challenging for researchers to determine the utility of these different forms of measurement. The current study examined the effect of laboratory episode characteristics (i.e., threat-level of the episode, maternal involvement) on concordance between maternal report and laboratory observation of toddler fear. The sample included 111 mother-toddler dyads who participated in a laboratory assessment when toddlers were approximately 24-months-old. Toddler fear was assessed both via maternal report and observation from a number of laboratory episodes that varied in their level of threat and whether mothers were free or constrained in their involvement in the task. Results indicated that maternal report related to the observed fear composites for low-threat, but not high-threat episodes. On the other hand, maternal involvement in the laboratory episodes did not moderate the relation between maternal report and laboratory observation of fear. These results suggest that the threat-level of laboratory episodes designed to elicit fear, but not maternal involvement in these episodes, may be important to take into consideration when assessing their relation to maternal report of fear and fearful temperament. PMID:27606826

  5. Fusion Safety Program annual report, fiscal year 1994

    NASA Astrophysics Data System (ADS)

    Longhurst, Glen R.; Cadwallader, Lee C.; Dolan, Thomas J.; Herring, J. Stephen; McCarthy, Kathryn A.; Merrill, Brad J.; Motloch, Chester C.; Petti, David A.

    1995-03-01

    This report summarizes the major activities of the Fusion Safety Program in fiscal year 1994. The Idaho National Engineering Laboratory (INEL) is the designated lead laboratory and Lockheed Idaho Technologies Company is the prime contractor for this program. The Fusion Safety Program was initiated in 1979. Activities are conducted at the INEL, at other DOE laboratories, and at other institutions, including the University of Wisconsin. The technical areas covered in this report include tritium safety, beryllium safety, chemical reactions and activation product release, safety aspects of fusion magnet systems, plasma disruptions, risk assessment failure rate data base development, and thermalhydraulics code development and their application to fusion safety issues. Much of this work has been done in support of the International Thermonuclear Experimental Reactor (ITER). Also included in the report are summaries of the safety and environmental studies performed by the Fusion Safety Program for the Tokamak Physics Experiment and the Tokamak Fusion Test Reactor and of the technical support for commercial fusion facility conceptual design studies. A major activity this year has been work to develop a DOE Technical Standard for the safety of fusion test facilities.

  6. 35. DETAILS AND SECTIONS OF FUEL ELEMENT SUPPORT PLATFORM, FUEL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    35. DETAILS AND SECTIONS OF FUEL ELEMENT SUPPORT PLATFORM, FUEL ELEMENT HOLDER, TRIP MECHANISM COVER, AND OTHER DETAILS. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-S-3. INEL INDEX CODE NUMBER: 075 0701 60 851 151977. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  7. 7. CONSTRUCTION PROGRESS VIEW (INTERIOR) OF CONTROL ROOM PANEL INSIDE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. CONSTRUCTION PROGRESS VIEW (INTERIOR) OF CONTROL ROOM PANEL INSIDE BUNKER. SHOWS OPENING TO CABLE CHASE, FOUR PULLEY DEVICES, POWER OUTLET, CONDUIT, AND EAST END WALL OF BUNKER. INEL PHOTO NUMBER 65-5441, TAKEN OCTOBER 20, 1965. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  8. GRABGAM Analysis of Ultra-Low-Level HPGe Gamma Spectra

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Winn, W.G.

    The GRABGAM code has been used successfully for ultra-low level HPGe gamma spectrometry analysis since its development in 1985 at Savannah River Technology Center (SRTC). Although numerous gamma analysis codes existed at that time, reviews of institutional and commercial codes indicated that none addressed all features that were desired by SRTC. Furthermore, it was recognized that development of an in-house code would better facilitate future evolution of the code to address SRTC needs based on experience with low-level spectra. GRABGAM derives its name from Gamma Ray Analysis BASIC Generated At MCA/PC.

  9. Audiovisual associations alter the perception of low-level visual motion

    PubMed Central

    Kafaligonul, Hulusi; Oluk, Can

    2015-01-01

    Motion perception is a pervasive nature of vision and is affected by both immediate pattern of sensory inputs and prior experiences acquired through associations. Recently, several studies reported that an association can be established quickly between directions of visual motion and static sounds of distinct frequencies. After the association is formed, sounds are able to change the perceived direction of visual motion. To determine whether such rapidly acquired audiovisual associations and their subsequent influences on visual motion perception are dependent on the involvement of higher-order attentive tracking mechanisms, we designed psychophysical experiments using regular and reverse-phi random dot motions isolating low-level pre-attentive motion processing. Our results show that an association between the directions of low-level visual motion and static sounds can be formed and this audiovisual association alters the subsequent perception of low-level visual motion. These findings support the view that audiovisual associations are not restricted to high-level attention based motion system and early-level visual motion processing has some potential role. PMID:25873869

  10. Laboratory and clinical data on wound healing by low-power laser from the Medical Institute of Vilafortuny, Spain

    NASA Astrophysics Data System (ADS)

    Trelles, Mario A.; Mayayo, E.; Resa, A. M.; Rigau, Josepa; Calvo, G.

    1991-05-01

    Low power laser has been claimed, both at laboratory and for clinical treatment to activate wound healing. Chronic ulcers respond very positively to laser treatment when particular rules of irradiation are take into account. The multiple etiology of chronic ulcers is not conductive to treatment selection, including laser treatment, if the associated illness is not taken into consideration. For more than 14 years our clinical experience have been significantly positive using lasers in the treatment of chronic ulcers. Our causistic, based on 242 cases treated from 1975 through 1983, has kept in many cases very close follow-up for an extended time periods of up to six years after healing. By controlling photographically and microscopically a chronic venous ulcer submitted to low density laser irradiation, as well as by studying the process of reparation of experimental ulcers and burns, produce on laboratory animal, the healing effects of laser radiation can be followed. Statistically, it is possible to estimate that low intensity laser irradiation produces faster reparation of damage tissue.

  11. A professional development model for medical laboratory scientists working in the immunohematology laboratory.

    PubMed

    Garza, Melinda N; Pulido, Lila A; Amerson, Megan; Ali, Faheem A; Greenhill, Brandy A; Griffin, Gary; Alvarez, Enrique; Whatley, Marsha; Hu, Peter C

    2012-01-01

    Transfusion medicine, a section of the Department of Laboratory Medicine at The University of Texas MD Anderson Cancer Center is committed to the education and advancement of its health care professionals. It is our belief that giving medical laboratory professionals a path for advancement leads to excellence and increases overall professionalism in the Immunohematology Laboratory. As a result of this strong commitment to excellence and professionalism, the Immunohematology laboratory has instituted a Professional Development Model (PDM) that aims to create Medical Laboratory Scientists (MLS) that are not only more knowledgeable, but are continually striving for excellence. In addition, these MLS are poised for advancement in their careers. The professional development model consists of four levels: Discovery, Application, Maturation, and Expert. The model was formulated to serve as a detailed path to the mastery of all process and methods in the Immunohematology Laboratory. Each level in the professional development model consists of tasks that optimize the laboratory workflow and allow for concurrent training. Completion of a level in the PDM is rewarded with financial incentive and further advancement in the field. The PDM for Medical Laboratory Scientists in the Immunohematology Laboratory fosters personal development, rewards growth and competency, and sets high standards for all services and skills provided. This model is a vital component of the Immunohematology Laboratory and aims to ensure the highest quality of care and standards in their testing. It is because of the success of this model and the robustness of its content that we hope other medical laboratories aim to reach the same level of excellence and professionalism, and adapt this model into their own environment.

  12. Low Copper Levels Associated with Low Carcass Weight in Wild Red Deer ( Cervus elaphus ) in Norway.

    PubMed

    Handeland, Kjell; Viljugrein, Hildegunn; Lierhagen, Syverin; Opland, Marthe; Tarpai, Attila; Vikøren, Turid

    2017-01-01

    Copper (Cu) deficiency is associated with several disease syndromes, including poor growth, in farmed red deer ( Cervus elaphus ), but little is known of the consequences of low Cu levels in free-ranging populations. Low hepatic Cu levels have been documented in several wild red deer populations along the west coast of Norway, with the lowest values found on the island of Hitra. We studied the relationship between liver Cu concentration and slaughter weight in 63 red deer calves and 69 yearlings shot on Hitra during the autumn hunting season of 2009. Less than half of each age class had adequate Cu levels (>20 μg/g dry weight) and 14% of the calves and 28% of the yearlings had levels indicating deficiency (<13 μg/g). For yearlings, but not calves, there was a significant increase in slaughter weight with increasing hepatic Cu level. The differences between yearlings and calves could be linked to differences in physiologic Cu status of the two age classes, in that red deer calves are born with much higher levels of hepatic Cu than are their mothers. Our data demonstrate an association between low levels of Cu and reduced growth rate in a free-ranging cervid population.

  13. Mixed and low-level waste treatment project: Appendix C, Health and safety criteria for the mixed and low-level waste treatment facility at the Idaho National Engineering Laboratory. Part 2, Chemical constituents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neupauer, R.M.; Thurmond, S.M.

    This report contains health and safety information relating to the chemicals that have been identified in the mixed waste streams at the Waste Treatment Facility at the Idaho National Engineering Laboratory. Information is summarized in two summary sections--one for health considerations and one for safety considerations. Detailed health and safety information is presented in material safety data sheets (MSDSs) for each chemical.

  14. Undergraduate Chemistry Laboratory

    ERIC Educational Resources Information Center

    Bretz, Stacey Lowery; Fay, Michael; Bruck, Laura B.; Towns, Marcy H.

    2013-01-01

    Forty chemistry faculty from American Chemical Society-approved departments were interviewed to determine their goals for undergraduate chemistry laboratory. Faculty were stratified by type of institution, departmental success with regard to National Science Foundation funding for laboratory reform, and level of laboratory course. Interview…

  15. The laboratory diagnosis of testosterone deficiency.

    PubMed

    Paduch, Darius A; Brannigan, Robert E; Fuchs, Eugene F; Kim, Edward D; Marmar, Joel L; Sandlow, Jay I

    2014-05-01

    The evaluation and treatment of hypogonadal men has become an important part of urologic practice. Fatigue, loss of libido, and erectile dysfunction are commonly reported, but nonspecific symptoms and laboratory verification of low testosterone (T) are an important part of evaluation in addition to a detailed history and physical examination. Significant intraindividual fluctuations in serum T levels, biologic variation of T action on end organs, the wide range of T levels in human serum samples, and technical limitations of currently available assays have led to poor reliability of T measurements in the clinical laboratory setting. There is no universally accepted threshold of T concentration that distinguishes eugonadal from hypogonadal men; thus, laboratory results have to be interpreted in the appropriate clinical setting. This review focuses on clinical, biological, and technological challenges that affect serum T measurements to educate clinicians regarding technological advances and limitations of the currently available laboratory methods to diagnose hypogonadism. A collaborative effort led by the American Urological Association between practicing clinicians, patient advocacy groups, government regulatory agencies, industry, and professional societies is underway to provide optimized assay platforms and evidence-based normal assay ranges to guide clinical decision making. Until such standardization is commonplace in clinical laboratories, the decision to treat should be based on the presence of signs and symptoms in addition to serum T measurements. Rigid interpretation of T ranges should not dictate clinical decision making or define coverage of treatment by third party payers. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Solubility and Solubility Product Determination of a Sparingly Soluble Salt: A First-Level Laboratory Experiment

    ERIC Educational Resources Information Center

    Bonomo, Raffaele P.; Tabbi, Giovanni; Vagliasindi, Laura I.

    2012-01-01

    A simple experiment was devised to let students determine the solubility and solubility product, "K"[subscript sp], of calcium sulfate dihydrate in a first-level laboratory. The students experimentally work on an intriguing equilibrium law: the constancy of the product of the ion concentrations of a sparingly soluble salt. The determination of…

  17. Cassava root diet induces low pyruvate levels.

    PubMed

    Golay, Van K

    2010-01-01

    The high cyanogenic-glucoside carbohydrate of the cassava root (Manihot esculenta) has special properties that make it an ideal therapeutic food for lowering nicotinamide adenine dinucleotide reduced form (NADH) and inducing Sirtuin (Sirt) gene overexpression when eaten in an exclusive mono-food diet regime. The author, using himself as the sole test subject, repeatedly induced low pyruvate levels (reflective of NADH levels) after being on the diet for 1-2 weeks at a time. The possible influences of exclusive cassava dieting on redox control and Sirtuin activation will be discussed.

  18. A Unique Automation Platform for Measuring Low Level Radioactivity in Metabolite Identification Studies

    PubMed Central

    Krauser, Joel; Walles, Markus; Wolf, Thierry; Graf, Daniel; Swart, Piet

    2012-01-01

    Generation and interpretation of biotransformation data on drugs, i.e. identification of physiologically relevant metabolites, defining metabolic pathways and elucidation of metabolite structures, have become increasingly important to the drug development process. Profiling using 14C or 3H radiolabel is defined as the chromatographic separation and quantification of drug-related material in a given biological sample derived from an in vitro, preclinical in vivo or clinical study. Metabolite profiling is a very time intensive activity, particularly for preclinical in vivo or clinical studies which have defined limitations on radiation burden and exposure levels. A clear gap exists for certain studies which do not require specialized high volume automation technologies, yet these studies would still clearly benefit from automation. Use of radiolabeled compounds in preclinical and clinical ADME studies, specifically for metabolite profiling and identification are a very good example. The current lack of automation for measuring low level radioactivity in metabolite profiling requires substantial capacity, personal attention and resources from laboratory scientists. To help address these challenges and improve efficiency, we have innovated, developed and implemented a novel and flexible automation platform that integrates a robotic plate handling platform, HPLC or UPLC system, mass spectrometer and an automated fraction collector. PMID:22723932

  19. Laboratory investigations: Low Earth orbit environment chemistry with spacecraft surfaces

    NASA Technical Reports Server (NTRS)

    Cross, Jon B.

    1990-01-01

    Long-term space operations that require exposure of material to the low earth orbit (LEO) environment must take into account the effects of this highly oxidative atmosphere on material properties and the possible contamination of the spacecraft surroundings. Ground-based laboratory experiments at Los Alamos using a newly developed hyperthermal atomic oxygen (AO) source have shown that not only are hydrocarbon based materials effected but that inorganic materials such as MoS2 are also oxidized and that thin protective coatings such as Al2O3 can be breached, producing oxidation of the underlying substrate material. Gas-phase reaction products, such as SO2 from oxidation of MoS2 and CO and CO2 from hydrocarbon materials, have been detected and have consequences in terms of spacecraft contamination. Energy loss through gas-surface collisions causing spacecraft drag has been measured for a few select surfaces and has been found to be highly dependent on the surface reactivity.

  20. Exploring Three-Phase Systems and Synchronous Motors: A Low-Voltage and Low-Cost Experiment at the Sophomore Level

    ERIC Educational Resources Information Center

    Schubert, T. F., Jr.; Jacobitz, F. G.; Kim, E. M.

    2011-01-01

    In order to meet changing curricular and societal needs, a three-phase system and synchronous motor laboratory experience for sophomore-level students in a wide variety of engineering majors was designed, implemented, and assessed. The experiment is unusual in its early placement in the curriculum, and in that it focuses primarily on basic…

  1. Factors influencing nesting success of burrowing owls in southeastern Idaho

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gleason, R.S.; Johnson, D.R.

    1985-01-31

    A burrowing owl (Athene cunicularia) population nesting on the Idaho National Engineering Laboratory (INEL) in southeastern Idaho utilized burrows excavated by badgers (Taxidea taxus) or natural cavities in lava flows as nesting sites. The size of the population was small (N = 13-14 pairs) in relation to the number of available nesting sites, suggesting that factors other than burrow availability limited this population. Rodents and Jerusalem crickets (Stenopelmatus fuscus) represented the primary prey utilized during the nesting season. This population demonstrated both a numerical (brood size) and functional (dietary) response to a decrease in the density of three species ofmore » rodents on the INEL during a drought in 1977. 11 references, 1 figure, 2 table.« less

  2. Discovery & Interaction in Astro 101 Laboratory Experiments

    NASA Astrophysics Data System (ADS)

    Maloney, Frank Patrick; Maurone, Philip; DeWarf, Laurence E.

    2016-01-01

    The availability of low-cost, high-performance computing hardware and software has transformed the manner by which astronomical concepts can be re-discovered and explored in a laboratory that accompanies an astronomy course for arts students. We report on a strategy, begun in 1992, for allowing each student to understand fundamental scientific principles by interactively confronting astronomical and physical phenomena, through direct observation and by computer simulation. These experiments have evolved as :a) the quality and speed of the hardware has greatly increasedb) the corresponding hardware costs have decreasedc) the students have become computer and Internet literated) the importance of computationally and scientifically literate arts graduates in the workplace has increased.We present the current suite of laboratory experiments, and describe the nature, procedures, and goals in this two-semester laboratory for liberal arts majors at the Astro 101 university level.

  3. NASA Glenn's Acoustical Testing Laboratory Awarded Accreditation by the National Voluntary Laboratory Accreditation Program

    NASA Technical Reports Server (NTRS)

    Akers, James C.; Cooper, Beth A.

    2004-01-01

    NASA Glenn Research Center's Acoustical Testing Laboratory (ATL) provides a comprehensive array of acoustical testing services, including sound pressure level, sound intensity level, and sound-power-level testing per International Standards Organization (ISO)1 3744. Since its establishment in September 2000, the ATL has provided acoustic emission testing and noise control services for a variety of customers, particularly microgravity space flight hardware that must meet International Space Station acoustic emission requirements. The ATL consists of a 23- by 27- by 20-ft (height) convertible hemi/anechoic test chamber and a separate sound-attenuating test support enclosure. The ATL employs a personal-computer-based data acquisition system that provides up to 26 channels of simultaneous data acquisition with real-time analysis (ref. 4). Specialized diagnostic tools, including a scanning sound-intensity system, allow the ATL's technical staff to support its clients' aggressive low-noise design efforts to meet the space station's acoustic emission requirement. From its inception, the ATL has pursued the goal of developing a comprehensive ISO 17025-compliant quality program that would incorporate Glenn's existing ISO 9000 quality system policies as well as ATL-specific technical policies and procedures. In March 2003, the ATL quality program was awarded accreditation by the National Voluntary Laboratory Accreditation Program (NVLAP) for sound-power-level testing in accordance with ISO 3744. The NVLAP program is administered by the National Institutes of Standards and Technology (NIST) of the U.S. Department of Commerce and provides third-party accreditation for testing and calibration laboratories. There are currently 24 NVLAP-accredited acoustical testing laboratories in the United States. NVLAP accreditation covering one or more specific testing procedures conducted in accordance with established test standards is awarded upon successful completion of an intensive

  4. A teaching intervention for reading laboratory experiments in college-level introductory chemistry

    NASA Astrophysics Data System (ADS)

    Kirk, Maria Kristine

    The purpose of this study was to determine the effects that a pre-laboratory guide, conceptualized as a "scientific story grammar," has on college chemistry students' learning when they read an introductory chemistry laboratory manual and perform the experiments in the chemistry laboratory. The participants (N = 56) were students enrolled in four existing general chemistry laboratory sections taught by two instructors at a women's liberal arts college. The pre-laboratory guide consisted of eight questions about the experiment, including the purpose, chemical species, variables, chemical method, procedure, and hypothesis. The effects of the intervention were compared with those of the traditional pre-laboratory assignment for the eight chemistry experiments. Measures included quizzes, tests, chemistry achievement test, science process skills test, laboratory reports, laboratory average, and semester grade. The covariates were mathematical aptitude and prior knowledge of chemistry and science processes, on which the groups differed significantly. The study captured students' perceptions of their experience in general chemistry through a survey and interviews with eight students. The only significant differences in the treatment group's performance were in some subscores on lecture items and laboratory items on the quizzes. An apparent induction period was noted, in that significant measures occurred in mid-semester. Voluntary study with the pre-laboratory guide by control students precluded significant differences on measures given later in the semester. The groups' responses to the survey were similar. Significant instructor effects on three survey items were corroborated by the interviews. The researcher's students were more positive about their pre-laboratory tasks, enjoyed the laboratory sessions more, and were more confident about doing chemistry experiments than the laboratory instructor's groups due to differences in scaffolding by the instructors.

  5. A feasibility study of the Xpert MTB/RIF test at the peripheral level laboratory in China.

    PubMed

    Ou, Xichao; Xia, Hui; Li, Qiang; Pang, Yu; Wang, Shengfen; Zhao, Bing; Song, Yuanyuan; Zhou, Yang; Zheng, Yang; Zhang, Zhijian; Zhang, Zhiying; Li, Junchen; Dong, Haiyan; Chi, Junying; Zhang, Jack; Kam, Kai Man; Huan, Shitong; Jun, Yue; Chin, Daniel P; Zhao, Yanlin

    2015-02-01

    To evaluate the performance of Xpert MTB/RIF (MTB/RIF) in the county-level tuberculosis (TB) laboratory in China. From April 2011 to January 2012, patients with suspected multidrug-resistant tuberculosis (MDR-TB) and non-MDR-TB were enrolled consecutively from four county-level TB laboratories. The detection of Mycobacterium tuberculosis (MTB) by MTB/RIF was compared to detection by Löwenstein-Jensen culture. The detection of rifampin resistance was compared to detection by conventional drug-susceptibility testing. The impact of multiple specimens on the performance of MTB/RIF was also evaluated. A total of 2142 suspected non-MDR-TB cases and 312 suspected MDR-TB cases were enrolled. For MTB detection in suspected non-MDR-TB cases, the sensitivity and specificity of MTB/RIF were 94.4% and 90.2%, respectively. The sensitivity in smear-negative patients was 88.8%. For the detection of rifampin resistance in suspected non-MDR-TB cases, the sensitivity and specificity of MTB/RIF were 87.1% and 97.9%, respectively. For the detection of rifampin resistance in suspected MDR-TB cases, the sensitivity and specificity of MTB/RIF were 87.1% and 91.0%, respectively. Using multiple sputum specimens had no significant influence on the performance of MTB/RIF for MTB detection. The introduction of MTB/RIF could increase the accuracy of detection of MTB and rifampin resistance in peripheral-level TB laboratories in China. One single specimen is adequate for TB diagnosis by MTB/RIF. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. Performance Evaluation of "Low-cost" Sensors for Measuring Gaseous and Particle Air Pollutants: Results from Two Years of Field and Laboratory Testing

    NASA Astrophysics Data System (ADS)

    Feenstra, B. J.; Polidori, A.; Tisopulos, L.; Papapostolou, V.; Zhang, H.; Pathmanabhan, J.

    2016-12-01

    In recent years great progress has been made in development of low-cost miniature air quality sensing technologies. Such low-cost sensors offer a prospect of providing a real-time spatially dense information on pollutants, however, the quality of the data produced by these sensors is so far untested. In an effort to inform the general public about the actual performance of commercially available low-cost air quality sensors, in June 2014 the South Coast Air Quality Management District (SCAQMD) has established the Air Quality Sensor Performance Evaluation Center (AQ-SPEC). This program performs a thorough characterization of low-cost sensors under ambient (in the field) and controlled (in the laboratory) conditions. During the field testing, air quality sensors are operated side-by-side with Federal Reference Methods and Federal Equivalent Methods (FRM and FEM, respectively), which are routinely used to measure the ambient concentration of gaseous or particle pollutants for regulatory purposes. Field testing is conducted at two of SCAQMD's existing air monitoring stations, one in Rubidoux and one near the I-710 freeway. Sensors that demonstrate an acceptable performance in the field are brought back to the lab where a "characterization chamber" is used to challenge these devices with known concentrations of different particle and gaseous pollutants under different temperature and relative humidity levels. Testing results for each sensor are then summarized in a technical report and, along with other relevant information, posted online on a dedicated website (www.aqmd.gov/aq-spec) to educate the public about the capabilities of commercially available sensors and their potential applications. During this presentation, the results from two years of field and laboratory testing will be presented. The major strengths and weaknesses of some of the most commonly available particle and gaseous sensors will be discussed.

  7. The effects of low-level ionizing radiation and copper exposure on the incidence of antibiotic resistance in lentic biofilm bacteria.

    PubMed

    McArthur, J Vaun; Dicks, Christian A; Bryan, A Lawrence; Tuckfield, R Cary

    2017-09-01

    Environmental reservoirs of antibiotic resistant bacteria are poorly understood. Understanding how the environment selects for resistance traits in the absence of antibiotics is critical in developing strategies to mitigate this growing menace. Indirect or co-selection of resistance by environmental pollution has been shown to increase antibiotic resistance. However no attention has been given to the effects of low-level ionizing radiation or the interactions between radiation and heavy metals on the maintenance or selection for antibiotic resistance (AR) traits. Here we explore the effect of radiation and copper on antibiotic resistance. Bacteria were collected from biofilms in two ponds - one impacted by low-level radiocesium and the other an abandoned farm pond. Through laboratory controlled experiments we examined the effects of increasing concentrations of copper on the incidence of antibiotic resistance. Differences were detected in the resistance profiles of the controls from each pond. Low levels (0.01 mM) of copper sulfate increased resistance but 0.5 mM concentrations of copper sulfate depressed the AR response in both ponds. A similar pattern was observed for levels of multiple antibiotic resistance per isolate. The first principal component response of isolate exposure to multiple antibiotics showed significant differences among the six isolate treatment combinations. These differences were clearly visualized through a discriminant function analysis, which showed distinct antibiotic resistance response patterns based on the six treatment groups. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. An Evaluation of Noise Levels in College Welding Laboratories and Its Effect on Student Hearing.

    ERIC Educational Resources Information Center

    Pontynen, Burton Ahlstrom

    The purpose of this study was to determine what noise levels existed at selected work stations in college welding laboratories while students were working and whether this noise exposure had any effect on the hearing acuity of students. Audiometric tests were administered to an experimental group of welding students in the noise of a welding…

  9. In-flight and laboratory vacuum-friction test results

    NASA Technical Reports Server (NTRS)

    Devine, E. J.; Evans, H. E.; Leasure, W. A.

    1973-01-01

    Coefficient of friction measurements were made for six unlubricated metal couples exposed to the space environment aboard the OV-1-13 spacecraft and exposed to laboratory vacuum. Materials studied included mutually soluble, partially soluble, and insoluble metal combinations. Two samples of each material couple were tested in space and in the laboratory using the disk and rider technique. Linear velocity was 0.10 cm/s (2.5 in/min) and rider normal load was 4.45 N (1 lb) for the gold versus silver couples and 8.90 N (2lb) for the other combinations. Results showed that friction data obtained in a clean ion-pumped laboratory vacuum of 10 to the minus 10 power materials with low mutual solubility can be correlated to operation in the vicinity of a typical scientific spacecraft that is exposed to an ambient pressure as low as 10 to the minus 12 power torr. The expected increase in coefficient of friction with solubility was shown. Material couples with high mutual solubility present the hazard of unpredictable drastic friction increase in orbit which may not be evident in laboratory testing at levels down to 10 to the minus 10 power torr. It was also shown that gross cold welding of unlubricated metals exposed to a satellite environment does not occur.

  10. New Jersey State Briefing Book for low-level radioactive waste management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The New Jersey state Briefing Book is one of a series of State briefing books on low-level radioactive waste management practices. It has been prepared to assist state and federal agency officials in planning for safe low-level radioactive waste disposal. The report contains a profile of low-level radioactive waste generators in New Jersey. The profile is the result of a survey of NRC licensees in New Jersey. The briefing book also contains a comprehensive assessment of low-level radioactive waste management issues and concerns as defined by all major interested parties including industry, government, the media, and interest groups. The assessmentmore » was developed through personal communications with representatives of interested parties, and through a review of media sources. Lastly, the briefing book provides demographic and socioeconomic data and a discussion of relevant government agencies and activities, all of which may impact waste management practices in New Jersey.« less

  11. North Carolina State Briefing Book for low-level radioactive waste management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The North Carolina State Briefing Book is one of a series of state briefing books on low-level radioactive waste management practices. It has been prepared to assist state and federal agency officials in planning for safe low-level radioactive waste disposal. The report contains a profile of low-level radioactive waste generators in North Carolina. The profile is the result of a survey of NRC licensees in North Carolina. The briefing book also contains a comprehensive assessment of low-level radioactive waste management issues and concerns as defined by all major interested parties including industry, government, the media, and interest groups. The assessmentmore » was developed through personal communications with representatives of interested parties, and through a review of media sources. Lastly, the briefing book provides demographic and socioeconomic data and a discussion of relevant government agencies and activities, all of which may impact waste management practices in North Carolina.« less

  12. Puerto Rico State Briefing Book for low-level radioactive waste management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The Puerto Rico State Briefing Book is one of a series of state briefing books on low-level radioactive waste management practices. It has been prepared to assist state and federal agency officials in planning for safe low-level radioactive waste disposal. The report contains a profile of low-level radioactive waste generators in Puerto Rico. The profile is the result of a survey of NRC licensees in Puerto Rico. The briefing book also contains a comprehensive assessment of low-level radioactive waste management issues and concerns as defined by all major interested parties including industry, government, the media, and interest groups. The assessmentmore » was developed through personal communications with representatives of interested parties, and through a review of media sources. Lastly, the briefing book provides demographic and socioeconomic data and a discussion of relevant government agencies and activities, all of which may impact waste management practices in Puerto Rico.« less

  13. Catch It Low to Prevent It High: Countering Low-Level Verbal Abuse.

    ERIC Educational Resources Information Center

    Goldstein, Arnold P.

    2000-01-01

    Focuses on the low-level aggression of verbal abuse demonstrated by children and adolescents. Describes the teasing, cursing, gossip, and ostracism associated with verbal abuse. Provides strategies for working with youth who are verbally aggressive including, how to reduce verbal maltreatment, how to engage in constructive communication, and ways…

  14. Systemic lupus erythematosus in a multiethnic U.S. cohort (LUMINA) XXVII: factors predictive of a decline to low levels of disease activity.

    PubMed

    Bertoli, A M; Alarcón, G S; McGwin, G; Fernández, M; Bastian, H M; Fessler, B J; Vilá, L M; Reveille, J D

    2006-01-01

    The objective of this study was to examine factors predictive of a decline to low levels of disease activity in a cohort of systemic lupus erythematosus (SLE) patients. Patients with SLE of Hispanic (from Texas or Puerto Rico), African-American or Caucasian ethnicity from a multiethnic cohort were included. A decline to low levels of disease activity was defined as a score < or =5 as per the Systemic Lupus Activity Measure-Revised (SLAM-R) at any annual study visit if preceded by a SLAM-R > or =8. Using Generalized Estimating Equation (GEE), socioeconomic-demographic, behavioral, function, psychological, laboratory and clinical data [disease manifestations, number of ACR criteria accrued at diagnosis and damage accrual as per the Systemic Lupus International Collaborating Clinics (SLICC) Damage Index (SDI)] from the visit preceding that meeting the definition were examined as predictors of decline to low levels of disease activity. Two-hundred and eighty-seven patients (67 Hispanics from Texas, 32 Hispanics form Puerto Rico, 120 African-Americans and 68 Caucasians), accounting for 632 visits were analyzed. In the GEE multivariable analysis, higher degrees of social support (OR = 1.208, 95% CI 1.059-1.379; P = 0.005) were predictive of a decline to low levels of disease activity, while the number of ACR criteria accrued at diagnosis (OR = 0.765, 95% CI 0.631-0.927; P = 0.006) and damage (OR = 0.850, 95% CI 0.743-0.972, P = 0.018) were negatively associated. These data suggest that a decline to low levels of disease activity in lupus patients seems to be multifactorial; this study also underscores the importance of social support for lupus patients.

  15. A Low-Cost Computer-Controlled Arduino-Based Educational Laboratory System for Teaching the Fundamentals of Photovoltaic Cells

    ERIC Educational Resources Information Center

    Zachariadou, K.; Yiasemides, K.; Trougkakos, N.

    2012-01-01

    We present a low-cost, fully computer-controlled, Arduino-based, educational laboratory (SolarInsight) to be used in undergraduate university courses concerned with electrical engineering and physics. The major goal of the system is to provide students with the necessary instrumentation, software tools and methodology in order to learn fundamental…

  16. 36. DETAILS AND SECTIONS OF SHIELDING TANK, FUEL ELEMENT SUPPORT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    36. DETAILS AND SECTIONS OF SHIELDING TANK, FUEL ELEMENT SUPPORT FRAME AND SUPPORT PLATFORM, AND SAFETY MECHANISM ASSEMBLY (SPRING-LOADED HINGE). F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-S-1. INEL INDEX CODE NUMBER: 075 0701 60 851 151975. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  17. 30. ELEVATION OF ARVFS FIELD TEST FACILITY SHOWING VIEW OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    30. ELEVATION OF ARVFS FIELD TEST FACILITY SHOWING VIEW OF SOUTH SIDE OF FACILITY, INCLUDING BUNKER, CABLE CHASE, SHIELDING TANK, AND FRAME ASSEMBLY. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-2. INEL INDEX CODE NUMBER: 075 0701 851 151971. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  18. 28. MAP SHOWING LOCATION OF ARVFS FACILITY AS BUILT. SHOWS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    28. MAP SHOWING LOCATION OF ARVFS FACILITY AS BUILT. SHOWS LINCOLN BOULEVARD, BIG LOST RIVER, AND NAVAL REACTORS FACILITY. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-101-2. DATED OCTOBER 12, 1965. INEL INDEX CODE NUMBER: 075 0101 851 151969. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  19. 26. VIEW OF METAL SHED OVER SHIELDING TANK WITH CAMERA ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    26. VIEW OF METAL SHED OVER SHIELDING TANK WITH CAMERA FACING SOUTHWEST. SHOWS OPEN SIDE OF SHED ROOF, HERCULON SHEET, AND HAND-OPERATED CRANE. TAKEN IN 1983. INEL PHOTO NUMBER 83-476-2-9, TAKEN IN 1983. PHOTOGRAPHER NOT NAMED. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  20. Low vitamin D levels predict clinical features of schizophrenia.

    PubMed

    Cieslak, Kristina; Feingold, Jordyn; Antonius, Daniel; Walsh-Messinger, Julie; Dracxler, Roberta; Rosedale, Mary; Aujero, Nicole; Keefe, David; Goetz, Deborah; Goetz, Raymond; Malaspina, Dolores

    2014-11-01

    Vitamin D plays crucial roles in neuroprotection and neurodevelopment, and low levels are commonly associated with schizophrenia. We considered if the association was spurious or causal by examining the association of Vitamin D with Leukocyte Telomere Length (LTL), a marker of cellular aging. Vitamin D levels in 22 well-characterized schizophrenia cases were examined with respect to symptoms, cognition, and functioning. LTL was assessed using quantitative polymerase chain reaction (qPCR). The results showed that 91% (20) had deficient or insufficient Vitamin D levels, which were associated with excitement and grandiosity, social anhedonia, and poverty of speech. Sex-specific analyses showed strong associations of hypovitamintosis D to negative symptoms and decreased premorbid adjustment in males, and to lesser hallucinations and emotional withdrawal, but increased anti-social aggression in females. In females LTL was furthermore associated with Vitamin D levels. This study demonstrates a relationship of low vitamin D levels with increased cellular aging in females. It is also the first study to demonstrate potential sex-specific profiles among schizophrenia cases with hypovitaminosis. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Low glutathione peroxidase activity levels in patients with vitiligo.

    PubMed

    Zedan, Hatem; Abdel-Motaleb, Amira Ali; Kassem, Nahed Mahmoud Ali; Hafeez, Heba Ahmed Abdel; Hussein, Mahmoud Rezk Abdelwhahed

    2015-01-01

    Vitiligo is an idiopathic skin disease characterized by white areas on the skin due to loss of the functional melanocytes, with possible involvement of oxidative stress. Glutathione peroxidase (GPx) is an antioxidant enzyme that protects cells against oxidative damage. To examine serum GPx levels in patients with vitiligo and to relate the findings to the clinical features. The study group included 60 patients with vitiligo and 30 matching healthy controls. GPx activity was evaluated using enzyme-linked immunosorbent assay. We found a significant decrease in serum GPx activity level in the patients with vitiligo compared to the healthy controls (0.29 ± 0.14 versus 0.47 ± 0.13, p < .001). The levels were significantly low in skin phenotypes III and IV (p < .001). Higher levels were also observed with increasing age (≥ 14 years), prolonged disease duration (≥ 3 years), and generalized and extensive vitiligo (< 50%). However, these variations were statistically insignificant. Low levels of serum GPx activity, indicative of a disturbed oxidant-antioxidant system, may contribute to the development of vitiligo. © 2014 Canadian Dermatology Association.

  2. Roles of laboratories and laboratory systems in effective tuberculosis programmes.

    PubMed

    Ridderhof, John C; van Deun, Armand; Kam, Kai Man; Narayanan, P R; Aziz, Mohamed Abdul

    2007-05-01

    Laboratories and laboratory networks are a fundamental component of tuberculosis (TB) control, providing testing for diagnosis, surveillance and treatment monitoring at every level of the health-care system. New initiatives and resources to strengthen laboratory capacity and implement rapid and new diagnostic tests for TB will require recognition that laboratories are systems that require quality standards, appropriate human resources, and attention to safety in addition to supplies and equipment. To prepare the laboratory networks for new diagnostics and expanded capacity, we need to focus efforts on strengthening quality management systems (QMS) through additional resources for external quality assessment programmes for microscopy, culture, drug susceptibility testing (DST) and molecular diagnostics. QMS should also promote development of accreditation programmes to ensure adherence to standards to improve both the quality and credibility of the laboratory system within TB programmes. Corresponding attention must be given to addressing human resources at every level of the laboratory, with special consideration being given to new programmes for laboratory management and leadership skills. Strengthening laboratory networks will also involve setting up partnerships between TB programmes and those seeking to control other diseases in order to pool resources and to promote advocacy for quality standards, to develop strategies to integrate laboratories functions and to extend control programme activities to the private sector. Improving the laboratory system will assure that increased resources, in the form of supplies, equipment and facilities, will be invested in networks that are capable of providing effective testing to meet the goals of the Global Plan to Stop TB.

  3. Mechanisms of low level light therapy

    NASA Astrophysics Data System (ADS)

    Hamblin, Michael R.; Demidova, Tatiana N.

    2006-02-01

    The use of low levels of visible or near infrared light for reducing pain, inflammation and edema, promoting healing of wounds, deeper tissues and nerves, and preventing tissue damage has been known for almost forty years since the invention of lasers. Originally thought to be a peculiar property of laser light (soft or cold lasers), the subject has now broadened to include photobiomodulation and photobiostimulation using non-coherent light. Despite many reports of positive findings from experiments conducted in vitro, in animal models and in randomized controlled clinical trials, LLLT remains controversial. This likely is due to two main reasons; firstly the biochemical mechanisms underlying the positive effects are incompletely understood, and secondly the complexity of rationally choosing amongst a large number of illumination parameters such as wavelength, fluence, power density, pulse structure and treatment timing has led to the publication of a number of negative studies as well as many positive ones. In particular a biphasic dose response has been frequently observed where low levels of light have a much better effect than higher levels. This introductory review will cover some of the proposed cellular chromophores responsible for the effect of visible light on mammalian cells, including cytochrome c oxidase (with absorption peaks in the near infrared) and photoactive porphyrins. Mitochondria are thought to be a likely site for the initial effects of light, leading to increased ATP production, modulation of reactive oxygen species and induction of transcription factors. These effects in turn lead to increased cell proliferation and migration (particularly by fibroblasts), modulation in levels of cytokines, growth factors and inflammatory mediators, and increased tissue oxygenation. The results of these biochemical and cellular changes in animals and patients include such benefits as increased healing in chronic wounds, improvements in sports injuries and

  4. Neuropeptide Y and α-MSH circadian levels in two populations with low body weight: anorexia nervosa and constitutional thinness.

    PubMed

    Galusca, Bogdan; Prévost, Gaëtan; Germain, Natacha; Dubuc, Isabelle; Ling, Yiin; Anouar, Youssef; Estour, Bruno; Chartrel, Nicolas

    2015-01-01

    Anorexia nervosa (AN) presents an adaptive appetite regulating profile including high levels of ghrelin and 26RFa (orexigenic) and low levels of leptin and PYY (anorexigenic). However, this adaptive mechanism is not effective in promoting food intake. The NPY/proopiomelanocortin (POMC) system plays a crucial role in the regulation of feeding behavior as NPY is the most potent orexigenic neuropeptide identified so far and as the POMC-derived peptide α-MSH drastically reduces food intake, and this peptidergic system has not been thoroughly studied in AN. The aim of the present study was thus to investigate whether a dysfunction of the NPY/POMC occurs in two populations with low body weight, AN and constitutional thinness (CT). This was a cross-sectional study performed in an endocrinological unit and in an academic laboratory. Three groups of age-matched young women were studied: 23 with AN (AN), 22 CT and 14 normal weight controls. Twelve-point circadian profiles of plasma NPY and α-MSH levels were measured in the three groups of investigated subjects. No significant circadian variation of NPY was detected between the three groups. Plasma α-MSH levels were significantly lower in AN (vs controls) all over the day. The CT group, compared to controls, presented lower levels of α-MSH in the morning and the evening, and an important rise during lunchtime. In AN patients, the NPY system is not up-regulated under chronic undernutrition suggesting that this may play a role in the inability of anorectic women to adapt food intake to their energy demand. In contrast, low circadian α-MSH levels integrate the adaptive profile of appetite regulation of this disease. Finally, in CT women, the important α-MSH peak detected during lunchtime could explain why these patients are rapidly food satisfied.

  5. Adaptive and maladaptive perfectionism, and professional burnout among medical laboratory scientists.

    PubMed

    Robakowska, Marlena; Tyrańska-Fobke, Anna; Walkiewicz, Maciej; Tartas, Małgorzata

    2018-05-22

    The goal of this paper is to verify the correlations between adaptive and maladaptive perfectionism and the selected demographic and job characteristics vs. professional burnout among medical laboratory scientists in Poland. The study group consisted of 166 laboratory scientists. The Polish Adaptive and Maladaptive Perfectionism Questionnaire (Szczucka) was used for testing perfectionism. The Oldenburg Burnout Inventory was used for examining burnout syndrome. Adaptive perfectionism was positively and maladaptive perfectionism was negatively correlated with both aspects of professional burnout: the disengagement from work and exhaustion. What is more, maladaptive perfectionism was correlated negatively with age and work experience. People in relationships have a higher level of disengagement and a higher level of exhaustion than single ones. The results of hierarchical regression analyses have revealed, after having controlled selected demographic and job factors, that a significant predictor of disengagement is the high level of adaptive perfectionism and low level of maladaptive perfectionism. In addition, a significant predictor of high level of exhaustion is the low level of maladaptive perfectionism. Professional burnout among medical laboratory scientists is of a specific nature. The "healthier" perfectionism they reveal, the higher level of burnout they present. In this profession, lower risk of burnout is represented by those who are characterized by the lack of confidence in the quality of their actions and a negative reaction to their own imperfections associated with imposed social obligation to be perfect. The individuals pursuing their internal high standards experience burnout faster. Med Pr 2018;69(3):253-260. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  6. Managing previously disposed waste to today's standards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1990-01-01

    A Radioactive Waste Management Complex (RWMC) was established at the Idaho National Engineering Laboratory (INEL) in 1952 for controlled disposal of radioactive waste generated at the INEL. Between 1954 and 1970 waste characterized by long lived, alpha emitting radionuclides from the Rocky Flats Plant was also buried at this site. Migration of radionuclides and other hazardous substances from the buried Migration of radionuclides and other hazardous substances from the buried waste has recently been detected. A Buried Waste Program (BWP) was established to manage cleanup of the buried waste. This program has four objectives: (1) determine contaminant sources, (2) determinemore » extent of contamination, (3) mitigate migration, and (4) recommend an alternative for long term management of the waste. Activities designed to meet these objectives have been under way since the inception of the program. The regulatory environment governing these activities is evolving. Pursuant to permitting activities under the Resource Conservation and Recovery Act (RCRA), the Department of Energy (DOE) and the Environmental Protection Agency (EPA) entered into a Consent Order Compliance Agreement (COCA) for cleanup of past practice disposal units at the INEL. Subsequent to identification of the RWMC as a release site, cleanup activities proceeded under dual regulatory coverage of RCRA and the Atomic Energy Act. DOE, EPA, and the State of Idaho are negotiating a RCRA/Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) Interagency Agreement (IAG) for management of waste disposal sites at the INEL as a result of the November 1989 listing of the INEL on the National Priority List (NPL). Decision making for selection of cleanup technology will be conducted under the CERCLA process supplemented as required to meet the requirements of the National Environmental Policy Act (NEPA). 7 figs.« less

  7. Entrainment in Laboratory Simulations of Cumulus Cloud Flows

    NASA Astrophysics Data System (ADS)

    Narasimha, R.; Diwan, S.; Subrahmanyam, D.; Sreenivas, K. R.; Bhat, G. S.

    2010-12-01

    A variety of cumulus cloud flows, including congestus (both shallow bubble and tall tower types), mediocris and fractus have been generated in a water tank by simulating the release of latent heat in real clouds. The simulation is achieved through ohmic heating, injected volumetrically into the flow by applying suitable voltages between diametral cross-sections of starting jets and plumes of electrically conducting fluid (acidified water). Dynamical similarity between atmospheric and laboratory cloud flows is achieved by duplicating values of an appropriate non-dimensional heat release number. Velocity measurements, made by laser instrumentation, show that the Taylor entrainment coefficient generally increases just above the level of commencement of heat injection (corresponding to condensation level in the real cloud). Subsequently the coefficient reaches a maximum before declining to the very low values that characterize tall cumulus towers. The experiments also simulate the protected core of real clouds. Cumulus Congestus : Atmospheric cloud (left), simulated laboratory cloud (right). Panels below show respectively total heat injected and vertical profile of heating in the laboratory cloud.

  8. "Low Testosterone Levels in Body Fluids Are Associated With Chronic Periodontitis".

    PubMed

    Kellesarian, Sergio Varela; Malmstrom, Hans; Abduljabbar, Tariq; Vohra, Fahim; Kellesarian, Tammy Varela; Javed, Fawad; Romanos, Georgios E

    2017-03-01

    There is a debate over the association between low testosterone levels in body fluids and the occurrence of chronic periodontitis (CP). The aim of the present systematic review was to assess whether low testosterone levels in body fluids reflect CP. In order to identify studies relevant to the focus question: "Is there a relationship between low testosterone levels in body fluids and CP?" an electronic search without time or language restrictions was conducted up to June 2016 in indexed databases using different keywords: periodontitis, chronic periodontitis, periodontal diseases, testosterone, and gonadal steroid hormones. A total of eight studies were included in the present systematic review. The number of study participants ranged from 24 to 1,838 male individuals with ages ranging from 15 to 95 years. Seven studies measured testosterone levels in serum, two studies in saliva, and one study in gingiva. Four studies reported a negative association between serum testosterone levels and CP. Two studies reported a positive association between decreased testosterone levels in serum and CP. Increased levels of salivary testosterone among patients with CP were reported in one study; whereas one study reported no significant difference in the concentration of salivary testosterone between patients with and without CP. One study identified significant increase in the metabolism of testosterone in the gingiva of patients with CP. Within the limits of the evidence available, the relationship between low testosterone levels and CP remains debatable and further longitudinal studies and control trials are needed.

  9. Low-background gamma-ray spectrometry for the international monitoring system

    DOE PAGES

    Greenwood, L. R.; Cantaloub, M. G.; Burnett, J. L.; ...

    2016-12-28

    PNNL has developed two low-background gamma-ray spectrometers in a new shallow underground laboratory, thereby significantly improving its ability to detect low levels of gamma-ray emitting fission or activation products in airborne particulate in samples from the IMS (International Monitoring System). Furthermore, the combination of cosmic veto panels, dry nitrogen gas to reduce radon and low background shielding results in a reduction of the background count rate by about a factor of 100 compared to detectors operating above ground at our laboratory.

  10. Laboratory Measurements of Charging of Apollo 17 Lunar Dust Grains by Low Energy Electrons

    NASA Technical Reports Server (NTRS)

    Abbas, Mian M.; Tankosic, Dragana; Spann, James F.; Dube, Michael J.; Gaskin, Jessica

    2007-01-01

    It is well recognized that the charging properties of individual micron/sub-micron size dust grains by various processes are expected to be substantially different from the currently available measurements made on bulk materials. Solar UV radiation and the solar wind plasma charge micron size dust grains on the lunar surface with virtually no atmosphere. The electrostatically charged dust grains are believed to be levitated and transported long distances over the lunar terminator from the day to the night side. The current models do not fully explain the lunar dust phenomena and laboratory measurements are needed to experimentally determine the charging properties of lunar dust grains. An experimental facility has been developed in the Dusty Plasma Laboratory at NASA Marshall Space Flight Center MSFC for investigating the charging properties of individual micron/sub-micron size positively or negatively charged dust grains by levitating them in an electrodynamic balance in simulated space environments. In this paper, we present laboratory measurements on charging of Apollo 17 individual lunar dust grains by low energy electron beams in the 5-100 eV energy range. The measurements are made by levitating Apollo 17 dust grains of 0.2 to 10 micrometer diameters, in an electrodynamic balance and exposing them to mono-energetic electron beams. The charging rates and the equilibrium potentials produced by direct electron impact and by secondary electron emission processes are discussed.

  11. Factors associated with low levels of lumbar strength in adolescents in Southern Brazil☆

    PubMed Central

    Silva, Diego Augusto Santos; Gonçalves, Eliane Cristina de Andrade; Grigollo, Leoberto Ricardo; Petroski, Edio Luiz

    2014-01-01

    OBJECTIVE: To determine the prevalence and factors associated with low levels of lumbar strength in adolescents. METHOD: This was a cross-sectional study involving 601 adolescents, aged 14 to 17 years, enrolled in public schools in the western region of Santa Catarina State - Southern Brazil. Lumbar strength was analyzed by the lumbar extension test developed by the Canadian Society of Exercise Physiology, which proposes different cutoffs for boys and girls. Independent variables were sex, age, socioeconomic status, dietary habits, alcohol consumption, physical activity, and aerobic fitness. For data analysis, univariate and multivariate logistic regression were used, with significance level of 5%. RESULTS: The prevalence of low levels of lumbar strength was 27.3%. The population subgroups most likely to present low levels of lumbar strength were females (OR: 1.54, 95% CI : 1.06 to 2.23), adolescents with low levels of aerobic fitness (OR: 2.10, 95% CI: 1.41 to 3.11) and the overweight (OR: 2.28, 95% CI: 1.35 to 3.81). CONCLUSION: Almost one-third of the studied students have low levels of lumbar strength. Interventions in the school population should be taken with special attention to female adolescents, those with low levels of aerobic fitness, and those with overweight, as these population subgroups were most likely to demostrate low levels of lumbar strength. PMID:25511000

  12. Fractal feature of sEMG from Flexor digitorum superficialis muscle correlated with levels of contraction during low-level finger flexions.

    PubMed

    Arjunan, Sridhar P; Kumar, Dinesh K; Naik, Ganesh R

    2010-01-01

    This research paper reports an experimental study on identification of the changes in fractal properties of surface Electromyogram (sEMG) with the changes in the force levels during low-level finger flexions. In the previous study, the authors have identified a novel fractal feature, Maximum fractal length (MFL) as a measure of strength of low-level contractions and has used this feature to identify various wrist and finger movements. This study has tested the relationship between the MFL and force of contraction. The results suggest that changes in MFL is correlated with the changes in contraction levels (20%, 50% and 80% maximum voluntary contraction (MVC)) during low-level muscle activation such as finger flexions. From the statistical analysis and by visualisation using box-plot, it is observed that MFL (p ≈ 0.001) is a more correlated to force of contraction compared to RMS (p≈0.05), even when the muscle contraction is less than 50% MVC during low-level finger flexions. This work has established that this fractal feature will be useful in providing information about changes in levels of force during low-level finger movements for prosthetic control or human computer interface.

  13. 21 CFR 878.5400 - Low level laser system for aesthetic use

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Low level laser system for aesthetic use 878.5400 Section 878.5400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5400 Low level...

  14. 21 CFR 878.5400 - Low level laser system for aesthetic use

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Low level laser system for aesthetic use 878.5400 Section 878.5400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5400 Low level...

  15. 21 CFR 878.5400 - Low level laser system for aesthetic use

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Low level laser system for aesthetic use 878.5400 Section 878.5400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5400 Low level...

  16. Multispectral simulation environment for modeling low-light-level sensor systems

    NASA Astrophysics Data System (ADS)

    Ientilucci, Emmett J.; Brown, Scott D.; Schott, John R.; Raqueno, Rolando V.

    1998-11-01

    Image intensifying cameras have been found to be extremely useful in low-light-level (LLL) scenarios including military night vision and civilian rescue operations. These sensors utilize the available visible region photons and an amplification process to produce high contrast imagery. It has been demonstrated that processing techniques can further enhance the quality of this imagery. For example, fusion with matching thermal IR imagery can improve image content when very little visible region contrast is available. To aid in the improvement of current algorithms and the development of new ones, a high fidelity simulation environment capable of producing radiometrically correct multi-band imagery for low- light-level conditions is desired. This paper describes a modeling environment attempting to meet these criteria by addressing the task as two individual components: (1) prediction of a low-light-level radiance field from an arbitrary scene, and (2) simulation of the output from a low- light-level sensor for a given radiance field. The radiance prediction engine utilized in this environment is the Digital Imaging and Remote Sensing Image Generation (DIRSIG) model which is a first principles based multi-spectral synthetic image generation model capable of producing an arbitrary number of bands in the 0.28 to 20 micrometer region. The DIRSIG model is utilized to produce high spatial and spectral resolution radiance field images. These images are then processed by a user configurable multi-stage low-light-level sensor model that applies the appropriate noise and modulation transfer function (MTF) at each stage in the image processing chain. This includes the ability to reproduce common intensifying sensor artifacts such as saturation and 'blooming.' Additionally, co-registered imagery in other spectral bands may be simultaneously generated for testing fusion and exploitation algorithms. This paper discusses specific aspects of the DIRSIG radiance prediction for low

  17. Low-level lasers and mRNA levels of reference genes used in Escherichia coli

    NASA Astrophysics Data System (ADS)

    Teixeira, A. F.; Machado, Y. L. R. C.; Fonseca, A. S.; Mencalha, A. L.

    2016-11-01

    Low-level lasers are widely used for the treatment of diseases and antimicrobial photodynamic therapy. Reverse transcriptase quantitative polymerase chain reaction (RT-qPCR) is widely used to evaluate mRNA levels and output data from a target gene are commonly relative to a reference mRNA that cannot vary according to treatment. In this study, the level of reference genes from Escherichia coli exposed to red or infrared lasers at different fluences was evaluated. E. coli AB1157 cultures were exposed to red (660 nm) and infrared (808 nm) lasers, incubated (20 min, 37 °C), the total RNA was extracted, and cDNA synthesis was performed to evaluate mRNA levels from arcA, gyrA and rpoA genes by RT-qPCR. Melting curves and agarose gel electrophoresis were carried out to evaluate specific amplification. Data were analyzed by geNorm, NormFinder and BestKeeper. The melting curve and agarose gel electrophoresis showed specific amplification. Although mRNA levels from arcA, gyrA or rpoA genes presented no significant variations trough a traditional statistical analysis, Excel-based tools revealed that these reference genes are not suitable for E. coli cultures exposed to lasers. Our data showed that exposure to low-level red and infrared lasers at different fluences alter the mRNA levels from arcA, gyrA and rpoA in E. coli cells.

  18. Roles of laboratories and laboratory systems in effective tuberculosis programmes

    PubMed Central

    van Deun, Armand; Kam, Kai Man; Narayanan, PR; Aziz, Mohamed Abdul

    2007-01-01

    Abstract Laboratories and laboratory networks are a fundamental component of tuberculosis (TB) control, providing testing for diagnosis, surveillance and treatment monitoring at every level of the health-care system. New initiatives and resources to strengthen laboratory capacity and implement rapid and new diagnostic tests for TB will require recognition that laboratories are systems that require quality standards, appropriate human resources, and attention to safety in addition to supplies and equipment. To prepare the laboratory networks for new diagnostics and expanded capacity, we need to focus efforts on strengthening quality management systems (QMS) through additional resources for external quality assessment programmes for microscopy, culture, drug susceptibility testing (DST) and molecular diagnostics. QMS should also promote development of accreditation programmes to ensure adherence to standards to improve both the quality and credibility of the laboratory system within TB programmes. Corresponding attention must be given to addressing human resources at every level of the laboratory, with special consideration being given to new programmes for laboratory management and leadership skills. Strengthening laboratory networks will also involve setting up partnerships between TB programmes and those seeking to control other diseases in order to pool resources and to promote advocacy for quality standards, to develop strategies to integrate laboratories’ functions and to extend control programme activities to the private sector. Improving the laboratory system will assure that increased resources, in the form of supplies, equipment and facilities, will be invested in networks that are capable of providing effective testing to meet the goals of the Global Plan to Stop TB. PMID:17639219

  19. Comparison of laboratory single species and field population-level effects of the pyrethroid insecticide lambda-cyhalothrin on freshwater invertebrates.

    PubMed

    Schroer, A F W; Belgers, J D M; Brock, T C M; Matser, A M; Maund, S J; Van den Brink, P J

    2004-04-01

    The toxicity of the pyrethroid insecticide lambda-cyhalothrin to freshwater invertebrates has been investigated using data from short-term laboratory toxicity tests and in situ bioassays and population-level effects in field microcosms. In laboratory tests, patterns of toxicity were consistent with previous data on pyrethroids. The midge Chaoborus obscuripes was most sensitive (48- and 96-h EC50 = 2.8 ng/L). Other insect larvae (Hemiptera, Ephemeroptera) and macrocrustacea (Amphipoda, Isopoda) were also relatively sensitive, with 48- and 96-h EC50 values between 10 and 100 ng/L. Generally, microcrustacea (Cladocera, Copepoda) and larvae of certain insect groups (Odonata and Chironomidae) were less sensitive, with 48-h EC50 values higher than 100 ng/L. Mollusca and Plathelminthes were insensitive and were unaffected at concentrations at and above the water solubility (5 microg/L). Generally, the EC50 values based on initial population responses in field enclosures were similar to values derived from laboratory tests with the same taxa. Also, the corresponding fifth and tenth percentile hazard concentrations (HC5 and HC10) were similar (laboratory HC5 = 2.7 ng/L and field HC5 = 4.1 ng/L; laboratory and field HC10 = 5.1 ng/L), at least when based on the same sensitive taxonomic groups (insects and crustaceans) and when a similar concentration range was taken into account. In the three field enclosure experiments and at a treatment level of 10 ng/L, consistent effects were observed for only one population (Chaoborus obscuripes), with recovery taking place within 3 to 6 weeks. The laboratory HC5 (2.7 ng/L) and HC10 (5.1 ng/L) based on acute EC50 values of all aquatic arthropod taxa were both lower than this 10 ng/L, a concentration that might represent the "regulatory acceptable concentration." The HC5 and HC10 values in this study in The Netherlands (based on static laboratory tests with freshwater arthropods) were very similar to those derived from a previous study in

  20. Effect of weight loss by a low-fat diet and a low-carbohydrate diet on peptide YY levels.

    PubMed

    Essah, P A; Levy, J R; Sistrun, S N; Kelly, S M; Nestler, J E

    2010-08-01

    To compare the effects of weight loss by an energy-restricted low-fat diet vs low-carbohydrate diet on serum peptide YY (PYY) levels. 8-Week prospective study of 30 obese adults (mean age: 42.8+/-2.0 years, mean body mass index 35.5+/-0.6 kg m(-2)). After 8 weeks, subjects on the low-carbohydrate diet lost substantially more weight than those on the low-fat diet (5.8 vs 0.99 kg, P<0.001). Weight loss by either diet resulted in a 9% reduction in both mean fasting serum PYY levels (baseline: 103.5+/-8.8 pg ml(-1), after weight loss: 94.1+/-6.5 pg ml(-1), P<0.01) and postprandial area under the curve (AUC) PYY (baseline: (20.5+/-1.5) x 10(3) pg h(-1) ml(-1), after weight loss: mean AUC PYY (18.8+/-1.4) x 10(3) pg h(-1) ml(-1), P<0.001). There was a trend towards lower levels of PYY with greater degrees of weight loss. Reduced PYY levels after weight loss by an energy-restricted low-fat or low-carbohydrate diet likely represents a compensatory response to maintain energy homeostasis and contributes to difficulty in weight loss during energy-restricted diets.

  1. Effect of weight loss by a low-fat diet and a low-carbohydrate diet on peptide YY levels

    PubMed Central

    Essah, P. A.; Levy, J. R.; Sistrun, S. N.; Kelly, S. M.; Nestler, J. E.

    2010-01-01

    Objective To compare the effects of weight loss by an energy-restricted low-fat diet versus low-carbohydrate diet on serum peptide YY (PYY) levels. Design 8-week prospective study of 30 obese adults (mean age: 42.8 ± 2.0 years, mean BMI 35.5 ± 0.6 kg/m2). Results After 8 weeks, subjects on the low-carbohydrate diet lost substantially more weight than those on the low-fat diet (5.8 kg vs. 0.99 kg, p<0.001). Weight loss by either diet resulted in a 9% reduction in both mean fasting serum PYY levels (baseline: 103.5 ± 8.8 pg/ml, after weight loss: 94.1 ± 6.5 pg/ml, p<0.01) and postprandial AUC PYY (baseline: (20.5 ± 1.5) × 103 pg·hr−1ml−1, after weight loss: mean AUC PYY (18.8 ± 1.4) × 103 pg·hr−1ml−1 p<0.001). There was a trend towards lower levels of PYY with greater degrees of weight loss. Conclusions Reduced PYY levels after weight loss by an energy-restricted low-fat or low-carbohydrate diet likely represents a compensatory response to maintain energy homeostasis and contributes to difficulty in weight loss during energy-restricted diets. PMID:20351741

  2. 27. AERIAL VIEW OF ARVFS FIELD TEST SITE AS IT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    27. AERIAL VIEW OF ARVFS FIELD TEST SITE AS IT LOOKED IN 1983. OBLIQUE VIEW FACING EAST. BUNKER IS IN FOREGROUND, PROTECTIVE SHED FOR WFRP AT TOP OF IMAGE. INEL PHOTO NUMBER 83-574-12-1, TAKEN IN 1983. PHOTOGRAPHER: ROMERO. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  3. Impact of low-level BK polyomavirus viremia on intermediate-term renal allograft function.

    PubMed

    Korth, Johannes; Widera, Marek; Dolff, Sebastian; Guberina, Hana; Bienholz, Anja; Brinkhoff, Alexandra; Anastasiou, Olympia Evdoxia; Kribben, Andreas; Dittmer, Ulf; Verheyen, Jens; Wilde, Benjamin; Witzke, Oliver

    2018-02-01

    BK polyomavirus (BKPyV)-associated nephropathy (PyVAN) is a significant cause of premature renal transplant failure. High-level BKPyV viremia is predictive for PyVAN; however, low-level BKPyV viremia does not necessarily exclude the presence of PyVAN. As data are limited regarding whether or not low-level BKPyV viremia has an effect on intermediate-term graft outcome, this study analyzes the impact of low-level BKPyV viremia on intermediate-term graft function and outcome compared with high-level viremia and non-viremic patients. All renal transplant patients received follow-up examinations at the Department of Nephrology, University Hospital Essen. Patients were screened for BKPyV viremia and stratified into three groups according to their maximum BKPyV load in serum (low-level viremia, high-level viremia, and no viremia). In 142 of 213 (67%) patients, BKPyV was never detected in serum; 42 of 213 (20%) patients were found positive for low-level viremia (≤10 4 copies/mL); and 29 of 213 (13%) patients showed high-level viremia (>10 4 copies/mL). No significant differences regarding transplant function and graft failure were observed between patients without BKPyV viremia (delta estimated glomerular filtration rate [eGFR] +0.1 mL/min [month 1 vs last visit at month 44]) and patients with low-level BKPyV viremia (delta eGFR -1.7 mL/min). In patients with high-level viremia, transplant function was significantly restricted (delta eGFR -6.5 mL/min) compared with low-level viremia until the last visit at 44 ± 9.7 months after transplantation. Although the graft function and graft loss were worse in the high-level viremia group compared with no viremia (eGFR 37 vs 45 mL/min), the difference was not significant. High-level viremia was associated with impaired graft function. In contrast, low-level BKPyV viremia had no significant impact on intermediate-term graft function. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Reverse transcription loop-mediated isothermal amplification (RT-LAMP), a light for mammalian transcript analysis in low-input laboratories.

    PubMed

    Pandey, Mamta; Singh, Dheer; Onteru, Suneel K

    2018-06-01

    Transcript analysis is usually performed by costly, time-consuming, and expertise intensive methods, like real time-PCR, microarray, etc. However, they are not much feasible in low-input laboratories. Therefore, we implemented the reverse transcription loop-mediated isothermal amplification (RT-LAMP) as a means of mammalian transcript analysis. Particularly, RT-LAMP was developed for buffalo aromatase cytochrome P450 (CYP19) transcript, to study its expression in 3D-cultured buffalo granulosa cells, which were exposed to lipopolysaccharide (LPS). The CYP19-RT-LAMP assay rapidly identified the LPS-induced downregulation of the CYP19 gene within 30 min at 63°C in a water bath. The assay was visualized via unaided eye by observing the change in turbidity and fluorescence, which were decreased by increasing the LPS exposure time to granulosa cells. Overall, the developed CYP19-RT-LAMP assay provided a hope on the application of RT-LAMP for mammalian transcript analysis in low-input laboratories. © 2017 Wiley Periodicals, Inc.

  5. Obelix, a new low-background HPGe at Modane Underground Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loaiza, P.; LAL, Univ. Paris-Sud, CNRS/IN2P3, 91405 Orsay; Brudanin, V.

    An ultra-low background coaxial HPGe detector for gamma-ray spectrometry with a relative efficiency of 160%, corresponding to a 600 cm{sup 3} Ge crystal, was installed at the Laboratoire Souterrain de Modane, France (4800 m.w.e). To reduce the instrinsic detector background, all parts involved in the detector cryostat were selected for their low radioactivity contamination. A shielding, composed of an inner layer of roman lead and an external layer of regular lead was installed, together with a system to reduce the Rn level inside the sample chamber. The shielding was designed to allow the measurement of Marinelli-shaped samples. We present the constructional detailsmore » which lead to a remarkable low detector background of 73 cts/kg·d in [40, 3000] keV. Measured samples showed that sensitivities about 100 μBq/kg in {sup 226}Ra and {sup 228}Th are reached for samples of some kg and 30 days of lifetime.« less

  6. Management of low-level radioactive waste in Israel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shabtai, B.; Brenner, S.; Ne`eman, E.

    1995-12-31

    Radioactive materials are used extensively in Israel in many areas and applications for medicine, industry, agriculture, research and development and others. Israel`s primary concern in waste management is population safety and environmental protection. The Ministry of The Environment (MOE), in cooperation with the Israeli Atomic Energy Commission (IAEC), supervise over the disposal system, and ensure an effective control. The MOE is responsible for the granting of permits to users of radioactive elements in about 300 plants and institutes, with about 2,200 installations. The MOE operates a computerized database management system (DBMS) on radioactive materials, with data on licensing, import andmore » distribution, waste disposal and transportation. Supervision over the disposal of LLRW has deepened recently, and periodic reports, based on the number of drums containing LLRW, which were transferred from all institutes in Israel to the NRWDS, were prepared. Draft regulations on the disposal of LLRW from institutes of research and education, hospitals, medical laboratories and other, have been recently prepared. These regulations include instructions on the disposal of solid and liquid LLRW as well as radioactive gases and vapors. As a general rule, no LLRW of any sort will be disposed of through the ordinary waste system or general sewage. However, in some extraordinary cases, residues of liquid LLRW are allowed to be disposed in this manner, if the requirements for disposal are satisfied. There are some conditions, in which solid LLRW might be treated as a conventional waste, as well as for safe emission of radioactive gases and aerosols. In light of these considerations, a new and more specific approach to radiation protection organizations and management of low-level radioactive waste problems, supervision and optimization is presented.« less

  7. Forearm muscle oxygenation decreases with low levels of voluntary contraction

    NASA Technical Reports Server (NTRS)

    Murthy, G.; Kahan, N. J.; Hargens, A. R.; Rempel, D. M.

    1997-01-01

    The purpose of our investigation was to determine if the near infrared spectroscopy technique was sensitive to changes in tissue oxygenation at low levels of isometric contraction in the extensor carpi radialis brevis muscle. Nine subjects were seated with the right arm abducted to 45 degrees, elbow flexed to 85 degrees, forearm pronated 45 degrees, and wrist and forearm supported on an armrest throughout the protocol. Altered tissue oxygenation was measured noninvasively with near infrared spectroscopy. The near infrared spectroscopy probe was placed over the extensor carpi radialis brevis of the subject's right forearm and secured with an elastic wrap. After 1 minute of baseline measurements taken with the muscle relaxed, four different loads were applied just proximal to the metacarpophalangeal joint such that the subjects isometrically contracted the extensor carpi radialis brevis at 5, 10, 15, and 50% of the maximum voluntary contraction for 1 minute each. A 3-minute recovery period followed each level of contraction. At the end of the protocol, with the probe still in place, a value for ischemic tissue oxygenation was obtained for each subject. This value was considered the physiological zero and hence 0% tissue oxygenation. Mean tissue oxygenation (+/-SE) decreased from resting baseline (100% tissue oxygenation) to 89 +/- 4, 81 +/- 8, 78 +/- 8, and 47 +/- 8% at 5, 10, 15, and 50% of the maximum voluntary contraction, respectively. Tissue oxygenation levels at 10, 15, and 50% of the maximum voluntary contraction were significantly lower (p < 0.05) than the baseline value. Our results indicate that tissue oxygenation significantly decreases during brief, low levels of static muscle contraction and that near infrared spectroscopy is a sensitive technique for detecting deoxygenation noninvasively at low levels of forearm muscle contraction. Our findings have important implications in occupational medicine because oxygen depletion induced by low levels of muscle

  8. Thirteenth annual U.S. DOE low-level radioactive waste management conference: Proceedings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1991-12-31

    The 40 papers in this document comprise the proceedings of the Department of Energy`s Thirteenth Annual Low-Level Radioactive Waste Management Conference that was held in Atlanta, Georgia, on November 19--21, 1991. General subjects addressed during the conference included: disposal facility design; greater-than-class C low-level waste; public acceptance considerations; waste certification; site characterization; performance assessment; licensing and documentation; emerging low-level waste technologies; waste minimization; mixed waste; tracking and transportation; storage; and regulatory changes. Papers have been processed separately for inclusion on the data base.

  9. Hyper-heuristics with low level parameter adaptation.

    PubMed

    Ren, Zhilei; Jiang, He; Xuan, Jifeng; Luo, Zhongxuan

    2012-01-01

    Recent years have witnessed the great success of hyper-heuristics applying to numerous real-world applications. Hyper-heuristics raise the generality of search methodologies by manipulating a set of low level heuristics (LLHs) to solve problems, and aim to automate the algorithm design process. However, those LLHs are usually parameterized, which may contradict the domain independent motivation of hyper-heuristics. In this paper, we show how to automatically maintain low level parameters (LLPs) using a hyper-heuristic with LLP adaptation (AD-HH), and exemplify the feasibility of AD-HH by adaptively maintaining the LLPs for two hyper-heuristic models. Furthermore, aiming at tackling the search space expansion due to the LLP adaptation, we apply a heuristic space reduction (SAR) mechanism to improve the AD-HH framework. The integration of the LLP adaptation and the SAR mechanism is able to explore the heuristic space more effectively and efficiently. To evaluate the performance of the proposed algorithms, we choose the p-median problem as a case study. The empirical results show that with the adaptation of the LLPs and the SAR mechanism, the proposed algorithms are able to achieve competitive results over the three heterogeneous classes of benchmark instances.

  10. Pulmonary lesion induced by low and high positive end-expiratory pressure levels during protective ventilation in experimental acute lung injury.

    PubMed

    Pássaro, Caroline P; Silva, Pedro L; Rzezinski, Andréia F; Abrantes, Simone; Santiago, Viviane R; Nardelli, Liliane; Santos, Raquel S; Barbosa, Carolina M L; Morales, Marcelo M; Zin, Walter A; Amato, Marcelo B P; Capelozzi, Vera L; Pelosi, Paolo; Rocco, Patricia R M

    2009-03-01

    To investigate the effects of low and high levels of positive end-expiratory pressure (PEEP), without recruitment maneuvers, during lung protective ventilation in an experimental model of acute lung injury (ALI). Prospective, randomized, and controlled experimental study. University research laboratory. Wistar rats were randomly assigned to control (C) [saline (0.1 mL), intraperitoneally] and ALI [paraquat (15 mg/kg), intraperitoneally] groups. After 24 hours, each group was further randomized into four groups (six rats each) at different PEEP levels = 1.5, 3, 4.5, or 6 cm H2O and ventilated with a constant tidal volume (6 mL/kg) and open thorax. Lung mechanics [static elastance (Est, L) and viscoelastic pressure (DeltaP2, L)] and arterial blood gases were measured before (Pre) and at the end of 1-hour mechanical ventilation (Post). Pulmonary histology (light and electron microscopy) and type III procollagen (PCIII) messenger RNA (mRNA) expression were measured after 1 hour of mechanical ventilation. In ALI group, low and high PEEP levels induced a greater percentage of increase in Est, L (44% and 50%) and DeltaP2, L (56% and 36%) in Post values related to Pre. Low PEEP yielded alveolar collapse whereas high PEEP caused overdistension and atelectasis, with both levels worsening oxygenation and increasing PCIII mRNA expression. In the present nonrecruited ALI model, protective mechanical ventilation with lower and higher PEEP levels than required for better oxygenation increased Est, L and DeltaP2, L, the amount of atelectasis, and PCIII mRNA expression. PEEP selection titrated for a minimum elastance and maximum oxygenation may prevent lung injury while deviation from these settings may be harmful.

  11. Creep Laboratory manual

    NASA Astrophysics Data System (ADS)

    Osgerby, S.; Loveday, M. S.

    1992-06-01

    A manual for the NPL Creep Laboratory, a collective name given to two testing laboratories, the Uniaxial Creep Laboratory and the Advanced High Temperature Mechanical Testing Laboratory, is presented. The first laboratory is devoted to uniaxial creep testing and houses approximately 50 high sensitivity creep machines including 10 constant stress cam lever machines. The second laboratory houses a low cycle fatigue testing machine of 100 kN capacity driven by a servo-electric actuator, five machines for uniaxial tensile creep testing of engineering ceramics at temperatures up to 1600C, and an electronic creep machine. Details of the operational procedures for carrying out uniaxial creep testing are given. Calibration procedures to be followed in order to comply with the specifications laid down by British standards, and to provide traceability back to the primary standards are described.

  12. High levels of reactive gaseous mercury observed at a high elevation research laboratory in the Rocky Mountains

    NASA Astrophysics Data System (ADS)

    Faïn, X.; Obrist, D.; Hallar, A. G.; McCubbin, I.; Rahn, T.

    2009-10-01

    The chemical cycling and spatiotemporal distribution of mercury in the troposphere is poorly understood. We measured gaseous elemental mercury (GEM), reactive gaseous mercury (RGM) and particulate mercury (HgP) along with carbon monoxide (CO), ozone (O3), aerosols, and meteorological variables at Storm Peak Laboratory at an elevation of 3200 m a.s.l., in Colorado, from 28 April to 1 July 2008. The mean mercury concentrations were 1.6 ng m-3 (GEM), 20 pg m-3 (RGM) and 9 pg m-3 (HgP). We observed eight events of strongly enhanced atmospheric RGM levels with maximum concentrations up to 137 pg m-3. RGM enhancement events lasted for long time periods of 2 to 6 days showing both enriched level during daytime and nighttime when other tracers (e.g., aerosols) showed different representations of boundary layer air and free tropospheric air. During seven of these events, RGM was inversely correlated to GEM (RGM/GEM regression slope ~-0.1), but did not exhibit correlations with ozone, carbon monoxide, or aerosol concentrations. Relative humidity was the dominant factor affecting RGM levels with high RGM levels always present whenever relative humidity was below 40 to 50%. We conclude that RGM enhancements observed at Storm Peak Laboratory were not induced by pollution events and were related to oxidation of tropospheric GEM. High RGM levels were not limited to upper tropospheric or stratospherically influenced air masses, indicating that entrainment processes and deep vertical mixing of free tropospheric air enriched in RGM may lead to high RGM levels throughout the troposphere and into the boundary layer over the Western United States. Based on backtrajectory analysis and a lack of mass balance between RGM and GEM, atmospheric production of RGM may also have occurred in some distance allowing for scavenging and/or deposition of RGM prior to reaching the laboratory. Our observations provide evidence that the tropospheric pool of mercury is frequently enriched in divalent

  13. Impacts of fishing low-trophic level species on marine ecosystems.

    PubMed

    Smith, Anthony D M; Brown, Christopher J; Bulman, Catherine M; Fulton, Elizabeth A; Johnson, Penny; Kaplan, Isaac C; Lozano-Montes, Hector; Mackinson, Steven; Marzloff, Martin; Shannon, Lynne J; Shin, Yunne-Jai; Tam, Jorge

    2011-08-26

    Low-trophic level species account for more than 30% of global fisheries production and contribute substantially to global food security. We used a range of ecosystem models to explore the effects of fishing low-trophic level species on marine ecosystems, including marine mammals and seabirds, and on other commercially important species. In five well-studied ecosystems, we found that fishing these species at conventional maximum sustainable yield (MSY) levels can have large impacts on other parts of the ecosystem, particularly when they constitute a high proportion of the biomass in the ecosystem or are highly connected in the food web. Halving exploitation rates would result in much lower impacts on marine ecosystems while still achieving 80% of MSY.

  14. Low voltage to high voltage level shifter and related methods

    NASA Technical Reports Server (NTRS)

    Mentze, Erik J. (Inventor); Buck, Kevin M. (Inventor); Hess, Herbert L. (Inventor); Cox, David F. (Inventor)

    2006-01-01

    A shifter circuit comprises a high and low voltage buffer stages and an output buffer stage. The high voltage buffer stage comprises multiple transistors arranged in a transistor stack having a plurality of intermediate nodes connecting individual transistors along the stack. The transistor stack is connected between a voltage level being shifted to and an input voltage. An inverter of this stage comprises multiple inputs and an output. Inverter inputs are connected to a respective intermediate node of the transistor stack. The low voltage buffer stage has an input connected to the input voltage and an output, and is operably connected to the high voltage buffer stage. The low voltage buffer stage is connected between a voltage level being shifted away from and a lower voltage. The output buffer stage is driven by the outputs of the high voltage buffer stage inverter and the low voltage buffer stage.

  15. Low-frequency outdoor-indoor noise level difference for wind turbine assessment.

    PubMed

    Thorsson, Pontus; Persson Waye, Kerstin; Smith, Michael; Ögren, Mikael; Pedersen, Eja; Forssén, Jens

    2018-03-01

    To increase the understanding of wind turbine noise on sleep, human physiological reactions need to be studied in a controlled laboratory setting. The paper presents an outdoor-indoor noise level difference as a function of frequency, applicable to creating wind turbine indoor sounds with the outdoor sounds as input. For this, a combination of measurement data and modeling results has been used. The suggested data are provided in a table.

  16. High levels of reactive gaseous mercury observed at a high elevation research laboratory in the Rocky Mountains

    NASA Astrophysics Data System (ADS)

    Faïn, X.; Obrist, D.; Hallar, A. G.; McCubbin, I.; Rahn, T.

    2009-07-01

    The chemical cycling and spatiotemporal distribution of mercury in the troposphere is poorly understood. We measured gaseous elemental mercury (GEM), reactive gaseous mercury (RGM) and particulate mercury (HgP) along with CO, ozone, aerosols, and meteorological variables at Storm Peak Laboratory at an elevation of 3200 m a.s.l., in Colorado, from 28 April to 1 July 2008. The mean mercury concentrations were 1.6 ng m-3 (GEM), 20 pg m-3 (RGM) and 9 pg m-3 (HgP). We observed eight events of strongly enhanced atmospheric RGM levels with maximum concentrations up to 135 pg m-3. RGM enhancement events were unrelated to daytime/nighttime patterns and lasted for long time periods of 2 to 6 days. During seven of these events, RGM was inversely correlated to GEM (RGM/GEM regression slope ~ -0.1), but did not exhibit correlations with ozone, carbon monoxide, or aerosol concentrations. Relative humidity was the dominant factor affecting RGM levels with high RGM levels always present whenever relative humidity was below 40 to 50%. We conclude that RGM enhancements observed at Storm Peak Laboratory were not induced by pollution events and were related to oxidation of tropospheric GEM, but the mechanism remain unclear. Based on backtrajectory analysis and a lack of mass balance between RGM and GEM, we propose that in situ production of RGM may have occurred in some distance allowing for scavenging and/or deposition of some RGM prior to reaching the laboratory, and that GEM oxidation is an important tropospheric Hg sink. Our observations provide evidence that the tropospheric pool of mercury is frequently enriched in divalent mercury and that high RGM levels are not limited to the upper troposphere.

  17. 5. CONSTRUCTION PROGRESS VIEW OF ASSEMBLY USED TO RAISE AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. CONSTRUCTION PROGRESS VIEW OF ASSEMBLY USED TO RAISE AND LOWER FUEL ELEMENTS. TAKEN FROM TOP OF SHIELDING TANK WITH CAMERA POINTING TOWARDS BOTTOM OF TANK. SHOWS LADDER, SQUARE LIFTING FRAME, FUEL ELEMENT HOLDERS, AND CABLE CYLINDERS. INEL PHOTO NUMBER 65-5434, TAKEN OCTOBER 20, 1965. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  18. 37. ELECTRICAL PLAN AND DETAILS. SHOWS PLANNED LOCATION OF PORTABLE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    37. ELECTRICAL PLAN AND DETAILS. SHOWS PLANNED LOCATION OF PORTABLE GENERATOR. FUNCTION OF FOUR-FOOT SQUARE PIT IS SHOWN AS 'D.C. POWER SUPPLY PIT.' F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-E-1. INEL INDEX CODE NUMBER: 075 0701 10 851 151973. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  19. [Assessment of the quality of laboratory diagnosis of intestinal parasitic diseases by the laboratories participating in the Federal System of External Quality Assessment of Clinical Laboratory Testing].

    PubMed

    Malakhov, V N; Dovgalev, A S; Astanina, S Iu; Serdiuk, A P

    2014-01-01

    In 2010-2013, the quality of microscopic detection of the causative agents ofparasitic diseases in the feces has been assessed by the specialists of the laboratories of the therapeutic-and-prophylactic institutions (TPIs) and Hygiene and Epidemiology Centers, Russian Inspectorate for the Protection of Consumer Rights and Human Welfare, which are participants of the Federal System of External Quality Assessment of Clinical Laboratory Testing. Thirty-two specimens containing 16 species of human helminths and 4 species of enteric protozoa in different combinations were examined. The findings suggest that the quality of microscopic detection of the causative agents of parasitic diseases is low in the laboratories of health care facilities and that the specialists of the laboratories of TPIs and Hygiene and Epidemiology Centers, Russian Inspectorate for the Protection of Consumer Rights and Human Welfare, do not not possess the knowledge and skills necessary to make a laboratory diagnosis of helminths and enteric protozoa. The average detection rates of helminths and protozoa were at a level of 64 and 36%, respectively. The correct results showed that the proportion of helminths and protozoa were 94.5 and 5.5%, respectively. According to the biological and epidemiological classification of helminths, there were higher detection rates for contact group parasites (Enterobius vermicularis and Hymenolepis nana) and geohelminths (Ascaris, Trichuris trichiura, and others). Biohelminths (Opisthorchis, tapeworms, and others) Were detectable slightly worse.

  20. Raptor responses to low-level jet aircraft and sonic booms

    USGS Publications Warehouse

    Ellis, David H.; Ellis, Catherine H.; Mindell, David P.

    1991-01-01

    We estimated effects of low-level military jet aircraft and mid- to high-altitude sonic booms (actual and simulated) on nesting peregrine falcons (Falco peregrinus) and seven other raptors by observing their responses to test stimuli, determining nesting success for the test year, and evaluating site reoccupancy rates for the year following the tests. Frequent and nearby jet aircraft passes: (1) sometimes noticeably alarmed birds, (2) occasionally caused birds to fly from perches or eyries, (3) most often evoked only minimal responses, and (4) were never associated with reproductive failure. Similarly, responses to real and simulated mid- to high-altitude sonic booms were often minimal and never appeared productivity limiting. Eighteen (95%) of 19 nest sites subjected to low-level jet flights and/or simulated sonic booms in 1980 fledged young during that year. Eighteen (95%) of 19 sites disturbed in 1980 were reoccupied by pairs or lone birds of the same species in 1981.We subjected four pairs of prairie falcons (Falco mexicanus) to low-level aircraft at ad libitum levels during the courtship and incubation phases when adults were most likely to abandon: all four eyries fledged young. From heart rate (HR) data taken via a telemetering egg at another prairie falcon eyrie, we determined that stimulus-induced HR alterations were comparable to rate changes for birds settling to incubate following flight.While encouraging, our findings cannot be taken as conclusive evidence that jet flights and/or sonic booms will have no long-term negative effects for other raptor species or for other areas. In addition, we did not experiment with totally naive wild adults, rotary-winged aircraft, or low-level sonic booms.

  1. SSHAC Level 1 Probabilistic Seismic Hazard Analysis for the Idaho National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Payne, Suzette Jackson; Coppersmith, Ryan; Coppersmith, Kevin

    A Probabilistic Seismic Hazard Analysis (PSHA) was completed for the Materials and Fuels Complex (MFC), Advanced Test Reactor (ATR), and Naval Reactors Facility (NRF) at the Idaho National Laboratory (INL). The PSHA followed the approaches and procedures for Senior Seismic Hazard Analysis Committee (SSHAC) Level 1 study and included a Participatory Peer Review Panel (PPRP) to provide the confident technical basis and mean-centered estimates of the ground motions. A new risk-informed methodology for evaluating the need for an update of an existing PSHA was developed as part of the Seismic Risk Assessment (SRA) project. To develop and implement the newmore » methodology, the SRA project elected to perform two SSHAC Level 1 PSHAs. The first was for the Fuel Manufacturing Facility (FMF), which is classified as a Seismic Design Category (SDC) 3 nuclear facility. The second was for the ATR Complex, which has facilities classified as SDC-4. The new methodology requires defensible estimates of ground motion levels (mean and full distribution of uncertainty) for its criteria and evaluation process. The INL SSHAC Level 1 PSHA demonstrates the use of the PPRP, evaluation and integration through utilization of a small team with multiple roles and responsibilities (four team members and one specialty contractor), and the feasibility of a short duration schedule (10 months). Additionally, a SSHAC Level 1 PSHA was conducted for NRF to provide guidance on the potential use of a design margin above rock hazard levels for the Spent Fuel Handling Recapitalization Project (SFHP) process facility.« less

  2. Evaluation of Low-Cost, Centimeter-Level Accuracy OEM GNSS Receivers

    DOT National Transportation Integrated Search

    2018-02-02

    This report discusses the results of a study to quantify the performance of low-cost, centimeter-level accurate Global Navigation Satellite Systems (GNSS) receivers that have appeared on the market in the last few years. Centimeter-level accuracy is ...

  3. USING MODELS TO EXTRAPOLATE POPULATION-LEVEL EFFECTS FROM LABORATORY TOXICITY TESTS IN SUPPORT OF POPULATION RISK ASSESSMENTS

    EPA Science Inventory

    Using models to extrapolate population-level effects from laboratory toxicity tests in support of population risk assessments. Munns, W.R., Jr.*, Anne Kuhn, Matt G. Mitro, and Timothy R. Gleason, U.S. EPA ORD NHEERL, Narragansett, RI, USA. Driven in large part by management goa...

  4. Effect of low-level laser-treated mesenchymal stem cells on myocardial infarction.

    PubMed

    El Gammal, Zaynab H; Zaher, Amr M; El-Badri, Nagwa

    2017-09-01

    Cardiovascular disease is the leading cause of death worldwide. Although cardiac transplantation is considered the most effective therapy for end-stage cardiac diseases, it is limited by the availability of matching donors and the complications of the immune suppressive regimen used to prevent graft rejection. Application of stem cell therapy in experimental animal models was shown to reverse cardiac remodeling, attenuate cardiac fibrosis, improve heart functions, and stimulate angiogenesis. The efficacy of stem cell therapy can be amplified by low-level laser radiation. It is well established that the bio-stimulatory effect of low-level laser is influenced by the following parameters: wavelength, power density, duration, energy density, delivery time, and the type of irradiated target. In this review, we evaluate the available experimental data on treatment of myocardial infarction using low-level laser. Eligible papers were characterized as in vivo experimental studies that evaluated the use of low-level laser therapy on stem cells in order to attenuate myocardial infarction. The following descriptors were used separately and in combination: laser therapy, low-level laser, low-power laser, stem cell, and myocardial infarction. The assessed low-level laser parameters were wavelength (635-804 nm), power density (6-50 mW/cm 2 ), duration (20-150 s), energy density (0.96-1 J/cm 2 ), delivery time (20 min-3 weeks after myocardial infarction), and the type of irradiated target (bone marrow or in vitro-cultured bone marrow mesenchymal stem cells). The analysis focused on the cardioprotective effect of this form of therapy, the attenuation of scar tissue, and the enhancement of angiogenesis as primary targets. Other effects such as cell survival, cell differentiation, and homing are also included. Among the evaluated protocols using different parameters, the best outcome for treating myocardial infarction was achieved by treating the bone marrow by one dose of low-level

  5. Stabilization of the yeast desaturase system by low levels of oxygen

    NASA Technical Reports Server (NTRS)

    Volkmann, C. M.; Klein, H. P.

    1983-01-01

    The stability of particulate palmitoyl-CoA desaturase preparations from anaerobically grown yeast cells was increased by exposure to low levels of oxygen. The stabilizing effect of oxygen may be based upon the increased amounts of palmitoleic acid and ergosterol that become available to the cells. These results suggest the evolutinary appearance of this system at a time when atmospheric oxygen was at a low level.

  6. Sensitisation to Aspergillus fumigatus and Penicillium notatum in laboratory workers.

    PubMed

    Boscolo, P; Piccolomini, R; Benvenuti, F; Catamo, G; Di Gioacchino, M

    1999-01-01

    Four workers in medical research laboratories, located in a basement level of a University facility equipped with a humidified air conditioning system, complained of cough and/or asthma and/or rhinitis during their normal working activities. Since exposure to toxic compounds was very low (similar to that of the outdoor environment) only microbiological monitoring was performed. Aspergillus fumigatus and Penicillium notatum were found in some laboratories. Eight laboratory workers (including the 4 symptomatic subjects) out of 26 investigated were found to be atopic. Specific IgE sensitisation to Aspergillus fumigatus was found in the 8 atopic and in the 6 non-atopic workers, while Penicililum notatum was found in 7 atopic and 4 non-atopic subjects. History, physical examination and laboratory data excluded the presence of aspergillosis or allergic bronchial aspergillosis in the sensitised subjects. Our results suggest that evaluation of immune parameters, along with monitoring of the working environment, may reduce the risk of sensitisation and/or allergic symptoms in atopic laboratory workers.

  7. Laboratory Computing Resource Center

    Science.gov Websites

    Systems Computing and Data Resources Purchasing Resources Future Plans For Users Getting Started Using LCRC Software Best Practices and Policies Getting Help Support Laboratory Computing Resource Center Laboratory Computing Resource Center Latest Announcements See All April 27, 2018, Announcements, John Low

  8. A low-power inverter-based CMOS level-crossing analog-to-digital converter for low-frequency biosignal sensing

    NASA Astrophysics Data System (ADS)

    Tanaka, Suiki; Niitsu, Kiichi; Nakazato, Kazuo

    2016-03-01

    Low-power analog-to-digital conversion is a key technique for power-limited biomedical applications such as power-limited continuous glucose monitoring. However, a conventional uniform-sampling analog-to-digital converter (ADC) is not suitable for nonuniform biosignals. A level-crossing ADC (LC-ADC) is a promising candidate for low-power biosignal processing because of its event-driven properties. The LC-ADC acquires data by level-crossing sampling. When an input signal crosses the threshold level, the LC-ADC samples the signal. The conventional LC-ADC employs a power-hungry comparator. In this paper, we present a low-power inverter-based LC-ADC. By adjusting the threshold level of the inverter, it can be used as a threshold-fixed window comparator. By using the inverter as an alternative to a comparator, power consumption can be markedly reduced. As a result, the total power consumption is successfully reduced by 90% of that of previous LC-ADC. The inverter-based LC-ADC was found to be very suitable for use in power-limited biomedical devices.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sailer, S.J.

    This Quality Assurance Project Plan (QAPJP) specifies the quality of data necessary and the characterization techniques employed at the Idaho National Engineering Laboratory (INEL) to meet the objectives of the Department of Energy (DOE) Waste Isolation Pilot Plant (WIPP) Transuranic Waste Characterization Quality Assurance Program Plan (QAPP) requirements. This QAPJP is written to conform with the requirements and guidelines specified in the QAPP and the associated documents referenced in the QAPP. This QAPJP is one of a set of five interrelated QAPjPs that describe the INEL Transuranic Waste Characterization Program (TWCP). Each of the five facilities participating in the TWCPmore » has a QAPJP that describes the activities applicable to that particular facility. This QAPJP describes the roles and responsibilities of the Idaho Chemical Processing Plant (ICPP) Analytical Chemistry Laboratory (ACL) in the TWCP. Data quality objectives and quality assurance objectives are explained. Sample analysis procedures and associated quality assurance measures are also addressed; these include: sample chain of custody; data validation; usability and reporting; documentation and records; audits and 0385 assessments; laboratory QC samples; and instrument testing, inspection, maintenance and calibration. Finally, administrative quality control measures, such as document control, control of nonconformances, variances and QA status reporting are described.« less

  10. Treatment of depression in low-level residential care facilities for the elderly.

    PubMed

    George, Kuruvilla; Davison, Tanya E; McCabe, Marita; Mellor, David; Moore, Kathleen

    2007-12-01

    The rate of recognition and treatment of depressed older people in nursing homes is low. Data from the low-level residential care population have not been reported. This study aimed to collect information about the treatment of depression among older persons living in low-level residential care (hostels). The participants comprised 300 elderly residents from ten low-level residential care facilities from various suburbs in metropolitan Melbourne. The participants were interviewed by a trained clinical psychologist to determine the presence or absence of major or minor depressive disorder using the Structured Clinical Interview for DSM-IV Axis I Disorder (SCID-I). Each participant was also administered the Standardized Mini-mental State Examination (SMMSE) to determine level of cognitive function. The clinical psychologist then reviewed all cases in consultation with a geropsychiatrist experienced in the diagnosis of depression among older people, prior to assigning a diagnosis of depression. An important finding in this study was the low treatment for currently depressed residents, with less than half of those in the sample who were depressed receiving treatment. However, 61 of the 96 residents out of the sample of 300 who were on antidepressants were not currently depressed. There is an under recognition and under treatment of currently depressed older people in low-level residential care facilities (hostels) just as has been reported in studies in nursing homes. However, there are high numbers receiving antidepressants who are not currently depressed.

  11. Low-level lasers affect Escherichia coli cultures in hyperosmotic stress

    NASA Astrophysics Data System (ADS)

    Pinheiro, C. C.; Barboza, L. L.; Paoli, F.; Fonseca, A. S.

    2015-08-01

    Physical characteristics and practical properties have made lasers of interest for biomedical applications. Effects of low-level lasers on biological tissues could occur or be measurable depending on cell type, presence of a pathologic process or whether the cells are in an adverse environment. The objective of this work was to evaluate the survival, morphology and filamentation of E. coli cells proficient and deficient in the repair of oxidative DNA lesions exposed low-level red and infrared lasers submitted to hyperosmotic stress. Wild type and endonuclease VIII deficient E. coli cells in exponential and stationary growth phase were exposed to red and infrared lasers and submitted to hyperosmotic stress. Cell viability, filamentation phenotype and cell morphology were evaluated. Cell viability was not significantly altered but previous laser exposure induced filamentation and an altered area of stressed cells depending on physiologic condition and presence of the DNA repair. Results suggest that previous exposure to low-level red and infrared lasers could not affect viability but induced morphologic changes in cells submitted to hyperosmotic stress depending on physiologic conditions and repair of oxidative DNA lesions.

  12. Video conferencing made easy

    NASA Technical Reports Server (NTRS)

    Larsen, D. Gail; Schwieder, Paul R.

    1993-01-01

    Network video conferencing is advancing rapidly throughout the nation, and the Idaho National Engineering Laboratory (INEL), a Department of Energy (DOE) facility, is at the forefront of the development. Engineers at INEL/EG&G designed and installed a very unique DOE videoconferencing system, offering many outstanding features, that include true multipoint conferencing, user-friendly design and operation with no full-time operators required, and the potential for cost effective expansion of the system. One area where INEL/EG&G engineers made a significant contribution to video conferencing was in the development of effective, user-friendly, end station driven scheduling software. A PC at each user site is used to schedule conferences via a windows package. This software interface provides information to the users concerning conference availability, scheduling, initiation, and termination. The menus are 'mouse' controlled. Once a conference is scheduled, a workstation at the hubs monitors the network to initiate all scheduled conferences. No active operator participation is required once a user schedules a conference through the local PC; the workstation automatically initiates and terminates the conference as scheduled. As each conference is scheduled, hard copy notification is also printed at each participating site. Video conferencing is the wave of the future. The use of these user-friendly systems will save millions in lost productivity and travel cost throughout the nation. The ease of operation and conference scheduling will play a key role on the extent industry uses this new technology. The INEL/EG&G has developed a prototype scheduling system for both commercial and federal government use.

  13. Video conferencing made easy

    NASA Astrophysics Data System (ADS)

    Larsen, D. Gail; Schwieder, Paul R.

    1993-02-01

    Network video conferencing is advancing rapidly throughout the nation, and the Idaho National Engineering Laboratory (INEL), a Department of Energy (DOE) facility, is at the forefront of the development. Engineers at INEL/EG&G designed and installed a very unique DOE videoconferencing system, offering many outstanding features, that include true multipoint conferencing, user-friendly design and operation with no full-time operators required, and the potential for cost effective expansion of the system. One area where INEL/EG&G engineers made a significant contribution to video conferencing was in the development of effective, user-friendly, end station driven scheduling software. A PC at each user site is used to schedule conferences via a windows package. This software interface provides information to the users concerning conference availability, scheduling, initiation, and termination. The menus are 'mouse' controlled. Once a conference is scheduled, a workstation at the hubs monitors the network to initiate all scheduled conferences. No active operator participation is required once a user schedules a conference through the local PC; the workstation automatically initiates and terminates the conference as scheduled. As each conference is scheduled, hard copy notification is also printed at each participating site. Video conferencing is the wave of the future. The use of these user-friendly systems will save millions in lost productivity and travel cost throughout the nation. The ease of operation and conference scheduling will play a key role on the extent industry uses this new technology. The INEL/EG&G has developed a prototype scheduling system for both commercial and federal government use.

  14. Video conferencing made easy

    NASA Astrophysics Data System (ADS)

    Larsen, D. G.; Schwieder, P. R.

    Network video conferencing is advancing rapidly throughout the nation, and the Idaho National Engineering Laboratory (INEL), a Department of Energy (DOE) facility, is at the forefront of the development. Engineers at INEL/EG&G designed and installed a very unique DOE video conferencing system, offering many outstanding features, that include true multipoint conferencing, user-friendly design and operation with no full-time operators required, and the potential for cost effective expansion of the system. One area where INEL/EG&G engineers made a significant contribution to video conferencing was in the development of effective, user-friendly, end station driven scheduling software. A PC at each user site is used to schedule conferences via a windows package. This software interface provides information to the users concerning conference availability, scheduling, initiation, and termination. The menus are 'mouse' controlled. Once a conference is scheduled, a workstation at the hub monitors the network to initiate all scheduled conferences. No active operator participation is required once a user schedules a conference through the local PC; the workstation automatically initiates and terminates the conference as scheduled. As each conference is scheduled, hard copy notification is also printed at each participating site. Video conferencing is the wave of the future. The use of these user-friendly systems will save millions in lost productivity and travel costs throughout the nation. The ease of operation and conference scheduling will play a key role on the extent industry uses this new technology. The INEL/EG&G has developed a prototype scheduling system for both commercial and federal government use.

  15. Low-level radiation: biological interactions, risks, and benefits. A bibliography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1978-09-01

    The bibliography contains 3294 references that were selected from the Department of Energy's data base (EDB). The subjects covered are lower-level radiation effects on man, environmental radiation, and other biological interactions of radiation that appear to be applicable to the low-level radiation problem.

  16. Ames Laboratory site environmental report, calendar year 1988

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mathison, L.K.

    1989-05-01

    The summarized data and conclusions from the Ames Laboratory environmental monitoring program are presented in this Annual Site Environmental Report. Ames Laboratory is located on the campus of Iowa State University (ISU) and occupies several buildings owned by the Department of Energy. A study is being conducted to identify environmental sampling methods which can characterize and separate the impact of Ames Laboratory's campus activities and that of ISU. This will enable the Laboratory to determine what possible impact it's operations may be having to the environment, if any. Two Pollution Abatement projects were begun in 1988. They were: removal ofmore » thorium contaminated soil resulting from a historical release of thorium at the Laboratory, to the Ames, Iowa Water Pollution Control (sewage) Plant and demolition of a small Blockhouse'' constructed of concrete block which had been used for low level radioactive waste handling. The contaminated soil has been removed and transported to Hanford, WA for disposal. A final site radiological survey for thorium is pending. In addition, contaminated debris was transported to Hanford, WA for disposal and a final site survey is pending. 7 refs., 4 figs., 1 tab.« less

  17. [Analysis of productivity, quality and cost of first grade laboratories: blood biometry].

    PubMed

    Avila, L; Hernández, P; Cruz, A; Zurita, B; Terres, A M; Cruz, C

    1999-04-01

    Assessment of productivity, quality and production costs and determination of the efficiency of top grade clinical laboratories in Mexico. Ten laboratories were selected from among the total number (52) existing in Mexico City, and the Donabedian model of structure, process and results were applied. Blood count was selected as a tracer. The principal problems found were: inadequate distribution of trained human resources, poor glass material, inadequate analytic process and low productivity. These factors are reflected in the unit costs, which exceed reference laboratory costs by 200%. Only 50% of the laboratories analyzed generate reliable results. Only 20% of the laboratories studied operate efficiently. To solve the problems identified requires integral strategies at different levels. A specific recomendation for the improvement of quality and productivity is an assessment of the cost/benefit of creating a central laboratory and using the remaining sites exclusively for the collection of samples.

  18. Statistical analysis of low level atmospheric turbulence

    NASA Technical Reports Server (NTRS)

    Tieleman, H. W.; Chen, W. W. L.

    1974-01-01

    The statistical properties of low-level wind-turbulence data were obtained with the model 1080 total vector anemometer and the model 1296 dual split-film anemometer, both manufactured by Thermo Systems Incorporated. The data obtained from the above fast-response probes were compared with the results obtained from a pair of Gill propeller anemometers. The digitized time series representing the three velocity components and the temperature were each divided into a number of blocks, the length of which depended on the lowest frequency of interest and also on the storage capacity of the available computer. A moving-average and differencing high-pass filter was used to remove the trend and the low frequency components in the time series. The calculated results for each of the anemometers used are represented in graphical or tabulated form.

  19. Biosafety and Biosecurity in European Containment Level 3 Laboratories: Focus on French Recent Progress and Essential Requirements.

    PubMed

    Pastorino, Boris; de Lamballerie, Xavier; Charrel, Rémi

    2017-01-01

    Even if European Union (EU) Member States are obliged to implement EU Directives 2000/54/EC on the protection of workers from risks related to exposure to biological agents at work , national biosafety regulations and practices varied from country to country. In fact, EU legislation on biological agents and genetically modified microorganisms is often not specific enough to ensure harmonization leading to difficulties in implementation for most laboratories. In the same way, biosecurity is a relatively new concept and a few EU Member States are known to have introduced national laboratory biosecurity legislation. In France, recent regulations have reinforced biosafety/biosecurity in containment level 3 (CL-3) laboratories but they concern a specific list of pathogens with no correlation in other European Members States. The objective of this review was to summarize European biosafety/biosecurity measures concerning CL-3 facilities focusing on French specificities. Essential requirements needed to preserve efficient biosafety measures when manipulating risk group 3 biological agents are highlighted. In addition, International, European and French standards related to containment laboratory planning, operation or biosafety equipment are described to clarify optimal biosafety and biosecurity requirements.

  20. Biosafety and Biosecurity in European Containment Level 3 Laboratories: Focus on French Recent Progress and Essential Requirements

    PubMed Central

    Pastorino, Boris; de Lamballerie, Xavier; Charrel, Rémi

    2017-01-01

    Even if European Union (EU) Member States are obliged to implement EU Directives 2000/54/EC on the protection of workers from risks related to exposure to biological agents at work, national biosafety regulations and practices varied from country to country. In fact, EU legislation on biological agents and genetically modified microorganisms is often not specific enough to ensure harmonization leading to difficulties in implementation for most laboratories. In the same way, biosecurity is a relatively new concept and a few EU Member States are known to have introduced national laboratory biosecurity legislation. In France, recent regulations have reinforced biosafety/biosecurity in containment level 3 (CL-3) laboratories but they concern a specific list of pathogens with no correlation in other European Members States. The objective of this review was to summarize European biosafety/biosecurity measures concerning CL-3 facilities focusing on French specificities. Essential requirements needed to preserve efficient biosafety measures when manipulating risk group 3 biological agents are highlighted. In addition, International, European and French standards related to containment laboratory planning, operation or biosafety equipment are described to clarify optimal biosafety and biosecurity requirements. PMID:28620600

  1. The low-level waste handbook: A user's guide to the Low-Level Radioactive Waste Policy Amendments Act of 1985. [Contains glossary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, H.

    1986-11-01

    This report provides a detailed, section-by-section analysis of the Low-Level Radioactive Waste Policy Amendments Act of 1985. Appendices include lists of relevant law and legislation, relevant Congressional committees, members of Congress mentioned in the report, and exact copies of the 1980 and 1985 Acts. (TEM)

  2. Laboratory evaluations of erectile dysfunction: an evidence based approach.

    PubMed

    Bodie, Joshua; Lewis, Jean; Schow, Doug; Monga, Manoj

    2003-06-01

    We evaluate the prevalence of laboratory abnormalities in men presenting for initial evaluation and therapy of erectile dysfunction. The computerized charts of men receiving treatment for erectile dysfunction from 1987 to 2002 were retrospectively reviewed. We pooled laboratory data for 3,547 men with erectile dysfunction to assess the prevalence of laboratory abnormalities. Values of the common laboratory screening tests for erectile dysfunction were recorded for testosterone, prolactin, luteinizing hormone, thyroid-stimulating hormone, hemoglobin A(Ic), prostate specific antigen, hemoglobin, cholesterol and creatinine. Of those patients evaluated 18.7% had low testosterone, 4.6% had increased prolactin, 14.6% had abnormal luteinizing hormone, 4.0% had increased thyroid-stimulating hormone, 8.3% had increased prostate specific antigen, 26.5% had anemia and 11.9% tested had renal insufficiency. A high percentage of patients presenting with a primary complaint of erectile dysfunction had increased hemoglobin A(Ic) and total serum cholesterol levels (52.9% and 48.4%, respectively). An evidence based approach to standardization of laboratory evaluations for men presenting with erectile dysfunction is recommended. Laboratory screening should be directed to identify those risk factors that may benefit from lifestyle modification and pharmacological intervention.

  3. Performance-assessment progress for the Rozan low-level waste disposal facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smietanski, L.; Mitrega, J.; Frankowski, Z.

    1995-12-31

    The paper presents a condensed progress report on the performance assessment of Poland`s low-level waste disposal facility which is operating since 1961. The Rozan repository is of near-surface type with facilities which are the concrete fortifications built about 1910. Site characterization activities supplied information on regional geology, geohydrology, climatic and hydrologic conditions and terrain surface evolution due to geodynamic processes. Field surveys enabled to decode lithological, hydrogeological and geochemical site specific conditions. From the laboratory tests the data on groundwater chemistry and soil geochemical and hydraulic characteristics were obtained. The site geohydrologic main vulnerable element is the upmost directly endangeredmore » unconfined aquifer which is perched in relation to the region-wide hydraulic system. Heterogeneity of this system reflects in a wide range of hydraulic conductivity and thickness variations. It strongly affects velocity and flow directions. The chemistry of groundwater is unstable due to large sensitivity to external impacts. Modeling of the migration of the critical long-lived radionuclides Tc-99, U-238 and Pu-239 showed that the nearly 20 m thick unsaturated zone plays crucial role as an effective protective barrier. These radionuclides constitute minor part of the total inventory. Modeling of the development of the H-3 plume pointed out the role the macrodispersion plays in the unsaturated zone beneath the repository.« less

  4. A Next Generation Digital Counting System For Low-Level Tritium Studies (Project Report)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bowman, P.

    2016-10-03

    Since the early seventies, SRNL has pioneered low-level tritium analysis using various nuclear counting technologies and techniques. Since 1999, SRNL has successfully performed routine low-level tritium analyses with counting systems based on digital signal processor (DSP) modules developed in the late 1990s. Each of these counting systems are complex, unique to SRNL, and fully dedicated to performing routine tritium analyses of low-level environmental samples. It is time to modernize these systems due to a variety of issues including (1) age, (2) lack of direct replacement electronics modules and (3) advances in digital signal processing and computer technology. There has beenmore » considerable development in many areas associated with the enterprise of performing low-level tritium analyses. The objective of this LDRD project was to design, build, and demonstrate a Next Generation Tritium Counting System (NGTCS), while not disrupting the routine low-level tritium analyses underway in the facility on the legacy counting systems. The work involved (1) developing a test bed for building and testing new counting system hardware that does not interfere with our routine analyses, (2) testing a new counting system based on a modern state of the art DSP module, and (3) evolving the low-level tritium counter design to reflect the state of the science.« less

  5. Intraocular levels of methotrexate after oral low-dose treatment in chronic uveitis.

    PubMed

    Puchta, Joachim; Hattenbach, Lars-Olof; Baatz, Holger

    2005-01-01

    To determine the intraocular levels of methotrexate in low-dose treatment of noninfectious uveitis. One day after oral administration, the methotrexate level was measured in the aqueous humor and serum of a patient with noninfectious uveitis, who underwent cataract surgery. A fluorescence polarization immunoassay was used for determination. After oral administration, methotrexate was only measurable in aqueous humor but not in serum. In uveitis, orally administered low-dose methotrexate reaches detectable levels in aqueous humor, even in the absence of detectable levels in serum. Copyright (c) 2005 S. Karger AG, Basel.

  6. The precedence effect for lateralization at low sensation levels.

    PubMed

    Goverts, S T; Houtgast, T; van Beek, H H

    2000-10-01

    Using dichotic signals presented by headphone, stimulus onset dominance (the precedence effect) for lateralization at low sensation levels was investigated for five normal hearing subjects. Stimuli were based on 2400-Hz low pass filtered 5-ms noise bursts. We used the paradigm, as described by Aoki and Houtgast (Hear. Res., 59 (1992) 25-30) and Houtgast and Aoki (Hear. Res., 72 (1994) 29-36), in which the stimulus is divided into a leading and a lagging part with opposite lateralization cues (i.e. an interaural time delay of 0.2 ms). The occurrence of onset dominance was investigated by measuring lateral perception of the stimulus, with fixed equal duration of leading and lagging part, while decreasing absolute signal level or adding a filtered white noise with the signal level set at 65 dBA. The dominance of the leading part was quantified by measuring the perceived lateral position of the stimulus as a function of the relative duration of the leading (and thus the lagging) part. This was done at about 45 dB SL without masking noise and also at a signal-to-noise ratio resulting in a sensation level of 10 dB. The occurrence and strength of the precedence effect was found to depend on sensation level, which was decreased either by lowering the signal level or by adding noise. With the present paradigm, besides a decreased lateralization accuracy, a decrease in the precedence effect was found for sensation levels below about 30-40 dB. In daily-life conditions, with a sensation level in noise of typically 10 dB, the onset dominance was still manifest, albeit degraded to some extent.

  7. Towards Smart Homes Using Low Level Sensory Data

    PubMed Central

    Khattak, Asad Masood; Truc, Phan Tran Ho; Hung, Le Xuan; Vinh, La The; Dang, Viet-Hung; Guan, Donghai; Pervez, Zeeshan; Han, Manhyung; Lee, Sungyoung; Lee, Young-Koo

    2011-01-01

    Ubiquitous Life Care (u-Life care) is receiving attention because it provides high quality and low cost care services. To provide spontaneous and robust healthcare services, knowledge of a patient’s real-time daily life activities is required. Context information with real-time daily life activities can help to provide better services and to improve healthcare delivery. The performance and accuracy of existing life care systems is not reliable, even with a limited number of services. This paper presents a Human Activity Recognition Engine (HARE) that monitors human health as well as activities using heterogeneous sensor technology and processes these activities intelligently on a Cloud platform for providing improved care at low cost. We focus on activity recognition using video-based, wearable sensor-based, and location-based activity recognition engines and then use intelligent processing to analyze the context of the activities performed. The experimental results of all the components showed good accuracy against existing techniques. The system is deployed on Cloud for Alzheimer’s disease patients (as a case study) with four activity recognition engines to identify low level activity from the raw data captured by sensors. These are then manipulated using ontology to infer higher level activities and make decisions about a patient’s activity using patient profile information and customized rules. PMID:22247682

  8. Lightning induced currents in aircraft wiring using low level injection techniques

    NASA Technical Reports Server (NTRS)

    Stevens, E. G.; Jordan, D. T.

    1991-01-01

    Various techniques were studied to predict the transient current induced into aircraft wiring bundles as a result of an aircraft lightning strike. A series of aircraft measurements were carried out together with a theoretical analysis using computer modeling. These tests were applied to various aircraft and also to specially constructed cylinders installed within coaxial return conductor systems. Low level swept frequency CW (carrier waves), low level transient and high level transient injection tests were applied to the aircraft and cylinders. Measurements were made to determine the transfer function between the aircraft drive current and the resulting skin currents and currents induced on the internal wiring. The full threat lightning induced transient currents were extrapolated from the low level data using Fourier transform techniques. The aircraft and cylinders used were constructed from both metallic and CFC (carbon fiber composite) materials. The results show the pulse stretching phenomenon which occurs for CFC materials due to the diffusion of the lightning current through carbon fiber materials. Transmission Line Matrix modeling techniques were used to compare theoretical and measured currents.

  9. The Response of Plant Species to Low-Level trampling Stress on Hurricane Island, Maine

    Treesearch

    R.E. Leonard; P.W. Conkling; J.L. McMahon; J.L. McMahon

    1985-01-01

    In 1981, a study was initiated to measure the effects of low-level trampling (100 to 200 tramples) on selected vegetation on Hurricane Island, Maine. Low levels of trampling are representative of general recreational use patterns on most Maine islands. The study was designed to compare percent survival of common island species when subjected to low-level trampling, to...

  10. The instantaneous rate dependence in low temperature laboratory rock friction and rock deformation experiments

    USGS Publications Warehouse

    Beeler, N.M.; Tullis, T.E.; Kronenberg, A.K.; Reinen, L.A.

    2007-01-01

    Earthquake occurrence probabilities that account for stress transfer and time-dependent failure depend on the product of the effective normal stress and a lab-derived dimensionless coefficient a. This coefficient describes the instantaneous dependence of fault strength on deformation rate, and determines the duration of precursory slip. Although an instantaneous rate dependence is observed for fracture, friction, crack growth, and low temperature plasticity in laboratory experiments, the physical origin of this effect during earthquake faulting is obscure. We examine this rate dependence in laboratory experiments on different rock types using a normalization scheme modified from one proposed by Tullis and Weeks [1987]. We compare the instantaneous rate dependence in rock friction with rate dependence measurements from higher temperature dislocation glide experiments. The same normalization scheme is used to compare rate dependence in friction to rock fracture and to low-temperature crack growth tests. For particular weak phyllosilicate minerals, the instantaneous friction rate dependence is consistent with dislocation glide. In intact rock failure tests, for each rock type considered, the instantaneous rate dependence is the same size as for friction, suggesting a common physical origin. During subcritical crack growth in strong quartzofeldspathic and carbonate rock where glide is not possible, the instantaneous rate dependence measured during failure or creep tests at high stress has long been thought to be due to crack growth; however, direct comparison between crack growth and friction tests shows poor agreement. The crack growth rate dependence appears to be higher than the rate dependence of friction and fracture by a factor of two to three for all rock types considered. Copyright 2007 by the American Geophysical Union.

  11. Session 35 - Panel: Remaining US Disposition Issues for Orphan or Small Volume Low Level and Low Level Mixed Waste Streams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blauvelt, Richard; Small, Ken; Gelles, Christine

    2006-07-01

    Faced with closure schedules as a driving force, significant progress has been made during the last 2 years on the disposition of DOE mixed waste streams thought previously to be problematic. Generators, the Department of Energy and commercial vendors have combined to develop unique disposition paths for former orphan streams. Recent successes and remaining issues will be discussed. The session will also provide an opportunity for Federal agencies to share lessons learned on low- level and mixed low-level waste challenges and identify opportunities for future collaboration. This panel discussion was organized by PAC member Dick Blauvelt, Navarro Research and Engineeringmore » Inc who served as co-chair along with Dave Eaton from INL. In addition, George Antonucci, Duratek Barnwell and Rich Conley, AFSC were invited members of the audience, prepared to contribute the Barnwell and DOD perspective to the issues as needed. Mr. Small provide information regarding the five year 20K M3 window of opportunity at the Nevada Test Site for DOE contractors to dispose of mixed waste that cannot be received at the Energy Solutions (Envirocare) site in Utah because of activity levels. He provided a summary of the waste acceptance criteria and the process sites must follow to be certified to ship. When the volume limit or time limit is met, the site will undergo a RCRA closure. Ms. Gelles summarized the status of the orphan issues, commercial options and the impact of the EM reorganization on her program. She also announced that there would be a follow-on meeting in 2006 to the very successful St. Louis meeting of last year. It will probably take place in Chicago in July. Details to be announced. Mr. McKenney discussed progress made at the Hanford Reservation regarding disposal of their mixed waste inventory. The news is good for the Hanford site but not good for the rest of the DOE complex since shipment for out of state of both low level and low level mixed waste will continue

  12. Teaching laboratory neuroscience at bowdoin: the laboratory instructor perspective.

    PubMed

    Hauptman, Stephen; Curtis, Nancy

    2009-01-01

    Bowdoin College is a small liberal arts college that offers a comprehensive Neuroscience major. The laboratory experience is an integral part of the major, and many students progress through three stages. A core course offers a survey of concepts and techniques. Four upper-level courses function to give students more intensive laboratory research experience in neurophysiology, molecular neurobiology, social behavior, and learning and memory. Finally, many majors choose to work in the individual research labs of the Neuroscience faculty. We, as laboratory instructors, are vital to the process, and are actively involved in all aspects of the lab-based courses. We provide student instruction in state of the art techniques in neuroscience research. By sharing laboratory teaching responsibilities with course professors, we help to prepare students for careers in laboratory neuroscience and also support and facilitate faculty research programs.

  13. Viability testing of material derived from Mycobacterium tuberculosis prior to removal from a Containment Level-III Laboratory as part of a Laboratory Risk Assessment Program

    PubMed Central

    Blackwood, Kym S; Burdz, Tamara V; Turenne, Christine Y; Sharma, Meenu K; Kabani, Amin M; Wolfe, Joyce N

    2005-01-01

    Background In the field of clinical mycobacteriology, Mycobacterium tuberculosis (MTB) can be a difficult organism to manipulate due to the restrictive environment of a containment level 3 (CL3) laboratory. Tests for rapid diagnostic work involving smears and molecular methods do not require CL3 practices after the organism has been rendered non-viable. While it has been assumed that after organism deactivation these techniques can be performed outside of a CL3, no conclusive study has consistently confirmed that the organisms are noninfectious after the theoretical 'deactivation' steps. Previous studies have shown that initial steps (such as heating /chemical fixation) may not consistently kill MTB organisms. Methods An inclusive viability study (n = 226) was undertaken to determine at which point handling of culture extraction materials does not necessitate a CL3 environment. Four different laboratory protocols tested for viability included: standard DNA extractions for IS6110 fingerprinting, crude DNA preparations for PCR by boiling and mechanical lysis, protein extractions, and smear preparations. For each protocol, laboratory staff planted a proportion of the resulting material to Bactec 12B medium that was observed for growth for 8 weeks. Results Of the 208 isolates initially tested, 21 samples grew within the 8-week period. Sixteen (7.7%) of these yielded positive results for MTB that included samples of: deactivated culture resuspensions exposed to 80°C for 20 minutes, smear preparations and protein extractions. Test procedures were consequently modified and tested again (n = 18), resulting in 0% viability. Conclusions This study demonstrates that it cannot be assumed that conventional practices (i.e. smear preparation) or extraction techniques render the organism non-viable. All methodologies, new and existing, should be examined by individual laboratories to validate the safe removal of material derived from MTB to the outside of a CL3 laboratory. This

  14. Viability testing of material derived from Mycobacterium tuberculosis prior to removal from a containment level-III laboratory as part of a Laboratory Risk Assessment Program.

    PubMed

    Blackwood, Kym S; Burdz, Tamara V; Turenne, Christine Y; Sharma, Meenu K; Kabani, Amin M; Wolfe, Joyce N

    2005-01-24

    In the field of clinical mycobacteriology, Mycobacterium tuberculosis (MTB) can be a difficult organism to manipulate due to the restrictive environment of a containment level 3 (CL3) laboratory. Tests for rapid diagnostic work involving smears and molecular methods do not require CL3 practices after the organism has been rendered non-viable. While it has been assumed that after organism deactivation these techniques can be performed outside of a CL3, no conclusive study has consistently confirmed that the organisms are noninfectious after the theoretical 'deactivation' steps. Previous studies have shown that initial steps (such as heating/chemical fixation) may not consistently kill MTB organisms. An inclusive viability study (n = 226) was undertaken to determine at which point handling of culture extraction materials does not necessitate a CL3 environment. Four different laboratory protocols tested for viability included: standard DNA extractions for IS6110 fingerprinting, crude DNA preparations for PCR by boiling and mechanical lysis, protein extractions, and smear preparations. For each protocol, laboratory staff planted a proportion of the resulting material to Bactec 12B medium that was observed for growth for 8 weeks. Of the 208 isolates initially tested, 21 samples grew within the 8-week period. Sixteen (7.7%) of these yielded positive results for MTB that included samples of: deactivated culture resuspensions exposed to 80 degrees C for 20 minutes, smear preparations and protein extractions. Test procedures were consequently modified and tested again (n = 18), resulting in 0% viability. This study demonstrates that it cannot be assumed that conventional practices (i.e. smear preparation) or extraction techniques render the organism non-viable. All methodologies, new and existing, should be examined by individual laboratories to validate the safe removal of material derived from MTB to the outside of a CL3 laboratory. This process is vital to establish in

  15. Investigating macroscopic, submicroscopic, and symbolic connections in a college-level general chemistry laboratory

    NASA Astrophysics Data System (ADS)

    Thadison, Felicia Culver

    Explanations of chemical phenomena rely on understanding the behavior of submicroscopic particles. Because this level is "invisible," it is described using symbols such as models, diagrams and equations. For this reason, students often view chemistry as a "difficult" subject. The laboratory offers a unique opportunity for the students to experience chemistry macroscopically as well as symbolically. The purpose of this investigation was to determine how chemistry lab students explained chemical phenomenon on the macroscopic, submicroscopic, and representational/symbolic level. The participants were undergraduate students enrolled in an introductory level general chemistry lab course. Students' background information (gender, the number of previous chemistry courses), scores on final exams, and final average for the course were collected. Johnstone's triangle of representation guided the design and implementation of this study. A semi-structured interview was also conducted to bring out student explanations. The questionnaires required students to draw a molecule of water, complete acid base reaction equations, represent, submicroscopically, the four stages of an acid-base titration, and provide definitions of various terms. Students were able represent the submicroscopic level of water. Students were not able to represent the submicroscopic level of the reaction between an acid and a base. Students were able to represent the macroscopic level of an acid base reaction. Students were able to symbolically represent the reaction of an acid and a base. These findings indicate that students can use all three levels of chemical representation. However, students showed an inability to connect the levels in relation to acid-base chemistry. There was no relationship between a student's ability to use the levels and his or her final score in the course.

  16. Chemical digestion of low level nuclear solid waste material

    DOEpatents

    Cooley, Carl R.; Lerch, Ronald E.

    1976-01-01

    A chemical digestion for treatment of low level combustible nuclear solid waste material is provided and comprises reacting the solid waste material with concentrated sulfuric acid at a temperature within the range of 230.degree.-300.degree.C and simultaneously and/or thereafter contacting the reacting mixture with concentrated nitric acid or nitrogen dioxide. In a special embodiment spent ion exchange resins are converted by this chemical digestion to noncombustible gases and a low volume noncombustible residue.

  17. Preliminary geological interpretation and lithologic log of the exploratory geothermal test well (INEL-1), Idaho National Engineering Laboratory, eastern Snake River Plain, Idaho

    USGS Publications Warehouse

    Doherty, David J.; McBroome, Lisa Ann; Kuntz, Mel A.

    1979-01-01

    A 10,365 ft (3,159 m) geothermal test well was drilled in the spring of 1979 at the Idaho National Engineering Laboratory, eastern Snake River Plain, Idaho: The majority of rock types encountered in the borehole are of volcanic origin. An upper section above 2,445 ft (745 m) consists of basaltic lava flows and interbedded .sediments of alluvial, lacustrine, and volcanic origin. A lower section below 2,445 ft (745 m) consists exclusively of rhyolitic welded ash-flow tuffs, air-fall ash deposits, nonwelded ash-flow ruffs, and volcaniclastic sediments. The lithology and thickness of the rhyolitic rocks suggest that they are part of an intracaldera fill.

  18. Teaching Low-Level Adult ESL Learners. ERIC Digest.

    ERIC Educational Resources Information Center

    Holt, Grace Massey

    In recent years, the English-as-a-Second-Language (ESL) teaching profession has made discoveries about teaching beginning or low-level adult learners (those with little or no schooling in their native languages, learners who may not be familiar with the Roman alphabet, those with learning disabilities, and those literate in their native languages…

  19. Low level waste management: a compilation of models and monitoring techniques. Volume 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mosier, J.E.; Fowler, J.R.; Barton, C.J.

    1980-04-01

    In support of the National Low-Level Waste (LLW) Management Research and Development Program being carried out at Oak Ridge National Laboratory, Science Applications, Inc., conducted a survey of models and monitoring techniques associated with the transport of radionuclides and other chemical species from LLW burial sites. As a result of this survey, approximately 350 models were identified. For each model the purpose and a brief description are presented. To the extent possible, a point of contact and reference material are identified. The models are organized into six technical categories: atmospheric transport, dosimetry, food chain, groundwater transport, soil transport, and surfacemore » water transport. About 4% of the models identified covered other aspects of LLW management and are placed in a miscellaneous category. A preliminary assessment of all these models was performed to determine their ability to analyze the transport of other chemical species. The models that appeared to be applicable are identified. A brief survey of the state-of-the-art techniques employed to monitor LLW burial sites is also presented, along with a very brief discussion of up-to-date burial techniques.« less

  20. Laboratory studies of low temperature rate coefficients: The atmospheric chemistry of the outer planets

    NASA Technical Reports Server (NTRS)

    Leone, Stephen R.

    1992-01-01

    The purpose of the project is to perform laboratory measurements of reaction rate coefficients at low temperature. The reactions and temperatures of interest are those that are important in the chemistry of the hydrocarbon rich atmospheres of the outer planets and their satellites. In this stage of the study we are investigating reactions of ethynyl radicals, C2H, with acetylene (C2H2), methane (CH4), and hydrogen (H2). In the previous status report from 24 Jan. 1992, we reported on the development of the experimental apparatus and the first, preliminary data for the C2H + C2H2 reaction.

  1. Low-level radioactive-waste burial at the Palos Forest Preserve, Illinois; geology and hydrology of the glacial drift, as related to the migration of tritium

    USGS Publications Warehouse

    Olimpio, Julio C.

    1984-01-01

    A low-level radioactive-waste burial site is located in Palos Forest Preserve, about 22 kilometers southwest of Chicago, Illinois. Between 1943 and 1949 the site, named Plot M, was filled with radioactive waste from the first Argonne National Laboratory and from the University of Chicago Metallurgical Laboratory. Since 1973, tritium concentration levels up to 14 nanocuries per liter have been measured in water samples collected from a well 360 meters from the burial site. The U.S. Geological Survey is studying the geologic, hydrologic, and geochemical properties of the glacial drift and underlying bedrock at the Plot M site to determine the factors that control the movement of radionuclides. Test wells were drilled into the drift to collect water and core samples for laboratory analysis, to gather geologic and hydrologic data, and to conduct geophysical surveys. Plot M is located in drift that ranges in thickness from 25 to 45 meters. The drift is a stratified sequence of clay- and silt-rich sediments that contain thin, interstratified sand layers. The silt content of the drift increases with depth. The permeability of the drift, as indicated by field and laboratory hydraulic conductivity tests, ranges from 1.0 x 10 -6 to 1.0 ? 10 -8 centimeters per second. A tritium plume, the contaminated zone in the drift in which tritium concentration levels exceed 10 nanocuries per liter of water, extends horizontally northward from Plot M at least 50 meters and vertically downward to bedrock. The center of the plume, where tritium concentration levels are as high as 50,000 nanocuries per liter, is approximately 15 meters beneath the burial site. The size, shape, and 'bull's-eye' concentration pattern indicate that the plume is a single slug and that the site no longer releases tritium into the drift. The leading edge, or front, of the plume (the 10 nanocuries per liter boundary) left the burial site in either the late 1940's or the early 1950's and intersected the underlying

  2. Laboratory Astrophysics White Paper: Summary of Laboratory Astrophysics Needs

    NASA Technical Reports Server (NTRS)

    2002-01-01

    The NASA Laboratory Astrophysics Workshop (NASA LAW) met at NASA Ames Research Center from 1-3 May 2002 to assess the role that laboratory astrophysics plays in the optimization of NASA missions, both at the science conception level and at the science return level. Space missions provide understanding of fundamental questions regarding the origin and evolution of galaxies, stars, and planetary systems. In all of these areas the interpretation of results from NASA's space missions relies crucially upon data obtained from the laboratory. We stress that Laboratory Astrophysics is important not only in the interpretation of data, but also in the design and planning of future missions. We recognize a symbiosis between missions to explore the universe and the underlying basic data needed to interpret the data from those missions. In the following we provide a summary of the consensus results from our Workshop, starting with general programmatic findings and followed by a list of more specific scientific areas that need attention. We stress that this is a 'living document' and that these lists are subject to change as new missions or new areas of research rise to the fore.

  3. Low Testosterone Levels in Body Fluids Are Associated With Chronic Periodontitis”

    PubMed Central

    Kellesarian, Sergio Varela; Malmstrom, Hans; Abduljabbar, Tariq; Vohra, Fahim; Kellesarian, Tammy Varela; Javed, Fawad; Romanos, Georgios E.

    2016-01-01

    There is a debate over the association between low testosterone levels in body fluids and the occurrence of chronic periodontitis (CP). The aim of the present systematic review was to assess whether low testosterone levels in body fluids reflect CP. In order to identify studies relevant to the focus question: “Is there a relationship between low testosterone levels in body fluids and CP?” an electronic search without time or language restrictions was conducted up to June 2016 in indexed databases using different keywords: periodontitis, chronic periodontitis, periodontal diseases, testosterone, and gonadal steroid hormones. A total of eight studies were included in the present systematic review. The number of study participants ranged from 24 to 1,838 male individuals with ages ranging from 15 to 95 years. Seven studies measured testosterone levels in serum, two studies in saliva, and one study in gingiva. Four studies reported a negative association between serum testosterone levels and CP. Two studies reported a positive association between decreased testosterone levels in serum and CP. Increased levels of salivary testosterone among patients with CP were reported in one study; whereas one study reported no significant difference in the concentration of salivary testosterone between patients with and without CP. One study identified significant increase in the metabolism of testosterone in the gingiva of patients with CP. Within the limits of the evidence available, the relationship between low testosterone levels and CP remains debatable and further longitudinal studies and control trials are needed. PMID:27645514

  4. Environmental Regulation of Plant Gene Expression: An Rt-qPCR Laboratory Project for an Upper-Level Undergraduate Biochemistry or Molecular Biology Course

    ERIC Educational Resources Information Center

    Eickelberg, Garrett J.; Fisher, Alison J.

    2013-01-01

    We present a novel laboratory project employing "real-time" RT-qPCR to measure the effect of environment on the expression of the "FLOWERING LOCUS C" gene, a key regulator of floral timing in "Arabidopsis thaliana" plants. The project requires four 3-hr laboratory sessions and is aimed at upper-level undergraduate…

  5. Low-level lasers alter mRNA levels from traditional reference genes used in breast cancer cells

    NASA Astrophysics Data System (ADS)

    Teixeira, A. F.; Canuto, K. S.; Rodrigues, J. A.; Fonseca, A. S.; Mencalha, A. L.

    2017-07-01

    Cancer is among the leading causes of mortality worldwide, increasing the importance of treatment development. Low-level lasers are used in several diseases, but some concerns remains on cancers. Reverse transcriptase quantitative polymerase chain reaction (RT-qPCR) is a technique used to understand cellular behavior through quantification of mRNA levels. Output data from target genes are commonly relative to a reference that cannot vary according to treatment. This study evaluated reference genes levels from MDA-MB-231 cells exposed to red or infrared lasers at different fluences. Cultures were exposed to red and infrared lasers, incubated (4 h, 37 °C), total RNA was extracted and cDNA synthesis was performed to evaluate mRNA levels from ACTB, GUSB and TRFC genes by RT-qPCR. Specific amplification was verified by melting curves and agarose gel electrophoresis. RefFinder enabled data analysis by geNorm, NormFinder and BestKeeper. Specific amplifications were obtained and, although mRNA levels from ACTB, GUSB or TRFC genes presented no significant variation through traditional statistical analysis, Excel-based tools revealed that the use of these reference genes are dependent of laser characteristics. Our data showed that exposure to low-level red and infrared lasers at different fluences alter the mRNA levels from ACTB, GUSB and TRFC in MDA-MB-231 cells.

  6. Green Chemistry Decision-Making in an Upper-Level Undergraduate Organic Laboratory

    ERIC Educational Resources Information Center

    Edgar, Landon J. G.; Koroluk, Katherine J.; Golmakani, Mehrnaz; Dicks, Andrew P.

    2014-01-01

    A self-directed independent synthesis experiment was developed for a third-year undergraduate organic laboratory. Students were provided with the CAS numbers of starting and target compounds and devised a synthetic plan to be executed over two 4.5 h laboratory periods. They consulted the primary literature in order to develop and carry out an…

  7. Harbour porpoises react to low levels of high frequency vessel noise

    PubMed Central

    Dyndo, Monika; Wiśniewska, Danuta Maria; Rojano-Doñate, Laia; Madsen, Peter Teglberg

    2015-01-01

    Cetaceans rely critically on sound for navigation, foraging and communication and are therefore potentially affected by increasing noise levels from human activities at sea. Shipping is the main contributor of anthropogenic noise underwater, but studies of shipping noise effects have primarily considered baleen whales due to their good hearing at low frequencies, where ships produce most noise power. Conversely, the possible effects of vessel noise on small toothed whales have been largely ignored due to their poor low-frequency hearing. Prompted by recent findings of energy at medium- to high-frequencies in vessel noise, we conducted an exposure study where the behaviour of four porpoises (Phocoena phocoena) in a net-pen was logged while they were exposed to 133 vessel passages. Using a multivariate generalised linear mixed-effects model, we show that low levels of high frequency components in vessel noise elicit strong, stereotyped behavioural responses in porpoises. Such low levels will routinely be experienced by porpoises in the wild at ranges of more than 1000 meters from vessels, suggesting that vessel noise is a, so far, largely overlooked, but substantial source of disturbance in shallow water areas with high densities of both porpoises and vessels. PMID:26095689

  8. Teaching chemistry and other sciences to blind and low-vision students through hands-on learning experiences in high school science laboratories

    NASA Astrophysics Data System (ADS)

    Supalo, Cary Alan

    2010-11-01

    Students with blindness and low vision (BLV) have traditionally been underrepresented in the sciences as a result of technological and attitudinal barriers to equal access in science laboratory classrooms. The Independent Laboratory Access for the Blind (ILAB) project developed and evaluated a suite of talking and audible hardware/software tools to empower students with BLV to have multisensory, hands-on laboratory learning experiences. This dissertation focuses on the first year of ILAB tool testing in mainstream science laboratory classrooms, and comprises a detailed multi-case study of four students with BLV who were enrolled in high school science classes during 2007--08 alongside sighted students. Participants attended different schools; curricula included chemistry, AP chemistry, and AP physics. The ILAB tools were designed to provide multisensory means for students with BLV to make observations and collect data during standard laboratory lessons on an equivalent basis with their sighted peers. Various qualitative and quantitative data collection instruments were used to determine whether the hands-on experiences facilitated by the ILAB tools had led to increased involvement in laboratory-goal-directed actions, greater peer acceptance in the students' lab groups, improved attitudes toward science, and increased interest in science. Premier among the ILAB tools was the JAWS/Logger Pro software interface, which made audible all information gathered through standard Vernier laboratory probes and visually displayed through Logger Pro. ILAB tools also included a talking balance, a submersible audible light sensor, a scientific talking stopwatch, and a variety of other high-tech and low-tech devices and techniques. While results were mixed, all four participating BLV students seemed to have experienced at least some benefit, with the effect being stronger for some than for others. Not all of the data collection instruments were found to reveal improvements for all

  9. Radioactive waste management complex low-level waste radiological composite analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCarthy, J.M.; Becker, B.H.; Magnuson, S.O.

    1998-05-01

    The composite analysis estimates the projected cumulative impacts to future members of the public from the disposal of low-level radioactive waste (LLW) at the Idaho National Engineering and Environmental Laboratory (INEEL) Radioactive Waste Management Complex (RWMC) and all other sources of radioactive contamination at the INEEL that could interact with the LLW disposal facility to affect the radiological dose. Based upon the composite analysis evaluation, waste buried in the Subsurface Disposal Area (SDA) at the RWMC is the only source at the INEEL that will significantly interact with the LLW facility. The source term used in the composite analysis consistsmore » of all historical SDA subsurface disposals of radionuclides as well as the authorized LLW subsurface disposal inventory and projected LLW subsurface disposal inventory. Exposure scenarios evaluated in the composite analysis include all the all-pathways and groundwater protection scenarios. The projected dose of 58 mrem/yr exceeds the composite analysis guidance dose constraint of 30 mrem/yr; therefore, an options analysis was conducted to determine the feasibility of reducing the projected annual dose. Three options for creating such a reduction were considered: (1) lowering infiltration of precipitation through the waste by providing a better cover, (2) maintaining control over the RWMC and portions of the INEEL indefinitely, and (3) extending the period of institutional control beyond the 100 years assumed in the composite analysis. Of the three options investigated, maintaining control over the RWMC and a small part of the present INEEL appears to be feasible and cost effective.« less

  10. Comprehensive evaluation of contemporary assisted reproduction technology laboratory operations to determine staffing levels that promote patient safety and quality care.

    PubMed

    Alikani, Mina; Go, Kathryn J; McCaffrey, Caroline; McCulloh, David H

    2014-11-01

    To consider how staffing requirements have changed with evolving and increasingly more complex assisted reproduction technology (ART) laboratory practice. Analysis by four laboratory directors from three different ART programs of the level of complexity and time requirements for contemporary ART laboratory activities to determine adequate staffing levels. University-based and private ART programs. None. None. Human resource requirements for ART procedures. Both complexity and time required for completion of a contemporary ART cycle have increased significantly compared with the same requirements for the "traditional cycle" of the past. The latter required roughly 9 personnel hours, but a contemporary cycle can require up to 20 hours for completion. Consistent with this increase, a quantitative analysis shows that the number of embryologists required for safe and efficient operation of the ART laboratory has also increased. This number depends on not only the volume but also the types of procedures performed: the higher the number of complex procedures, the more personnel required. An interactive Personnel Calculator is introduced that can help determine staffing needs. The increased complexity of the contemporary ART laboratory requires a new look at the allocation of human resources. Our work provides laboratory directors with a practical, individualized tool to determine their staffing requirements with a view to increasing the safety and efficiency of operations. The work could serve as the basis for revision of the 2008 American Society for Reproductive Medicine (ASRM) staffing guidelines. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  11. A Simple and Low-Cost Monitoring System to Investigate Environmental Conditions in a Biological Research Laboratory.

    PubMed

    Gurdita, Akshay; Vovko, Heather; Ungrin, Mark

    2016-01-01

    Basic equipment such as incubation and refrigeration systems plays a critical role in nearly all aspects of the traditional biological research laboratory. Their proper functioning is therefore essential to ensure reliable and repeatable experimental results. Despite this fact, in many academic laboratories little attention is paid to validating and monitoring their function, primarily due to the cost and/or technical complexity of available commercial solutions. We have therefore developed a simple and low-cost monitoring system that combines a "Raspberry Pi" single-board computer with USB-connected sensor interfaces to track and log parameters such as temperature and pressure, and send email alert messages as appropriate. The system is controlled by open-source software, and we have also generated scripts to automate software setup so that no background in programming is required to install and use it. We have applied it to investigate the behaviour of our own equipment, and present here the results along with the details of the monitoring system used to obtain them.

  12. Changes in soil hydraulic properties caused by construction of a simulated waste trench at the Idaho National Engineering Laboratory, Idaho

    USGS Publications Warehouse

    Shakofsky, S.M.

    1995-01-01

    In order to assess the effect of filled waste disposal trenches on transport-governing soil properties, comparisons were made between profiles of undisturbed soil and disturbed soil in a simulated waste trench. The changes in soil properties induced by the construction of a simulated waste trench were measured near the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory (INEL) in the semi-arid southeast region of Idaho. The soil samples were collected, using a hydraulically- driven sampler to minimize sample disruption, from both a simulated waste trench and an undisturbed area nearby. Results show that the undisturbed profile has distinct layers whose properties differ significantly, whereas the soil profile in the simulated waste trench is. by comparison, homogeneous. Porosity was increased in the disturbed cores, and, correspondingly, saturated hydraulic conductivities were on average three times higher. With higher soil-moisture contents (greater than 0.32), unsaturated hydraulic conductivities for the undisturbed cores were typically greater than those for the disturbed cores. With lower moisture contents, most of the disturbed cores had greater hydraulic conductivities. The observed differences in hydraulic conductivities are interpreted and discussed as changes in the soil pore geometry.

  13. Regulatory controls on the hydrogeological characterization of a mixed waste disposal site, Radioactive Waste Management Complex, Idaho National Engineering Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruebelmann, K.L.

    1990-01-01

    Following the detection of chlorinated volatile organic compounds in the groundwater beneath the SDA in the summer of 1987, hydrogeological characterization of the Radioactive Waste Management Complex (RWMC), Idaho National Engineering Laboratory (INEL) was required by the Resource Conservation and Recovery Act (RCRA). The waste site, the Subsurface Disposal Area (SDA), is the subject of a RCRA Corrective Action Program. Regulatory requirements for the Corrective Action Program dictate a phased approach to evaluation of the SDA. In the first phase of the program, the SDA is the subject of a RCRA Facility Investigation (RIF), which will obtain information to fullymore » characterize the physical properties of the site, determine the nature and extent of contamination, and identify pathways for migration of contaminants. If the need for corrective measures is identified during the RIF, a Corrective Measures Study (CMS) will be performed as second phase. Information generated during the RIF will be used to aid in the selection and implementation of appropriate corrective measures to correct the release. Following the CMS, the final phase is the implementation of the selected corrective measures. 4 refs., 1 fig.« less

  14. Evaluation of Low-Level Waste Disposal Receipt Data for Los Alamos National Laboratory Technical Area 54, Area G Disposal Facility - Fiscal Year 2011

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    French, Sean B.; Shuman, Robert

    2012-04-17

    The Los Alamos National Laboratory (LANL or the Laboratory) generates radioactive waste as a result of various activities. Operational or institutional waste is generated from a wide variety of research and development activities including nuclear weapons development, energy production, and medical research. Environmental restoration (ER), and decontamination and decommissioning (D and D) waste is generated as contaminated sites and facilities at LANL undergo cleanup or remediation. The majority of this waste is low-level radioactive waste (LLW) and is disposed of at the Technical Area 54 (TA-54), Area G disposal facility. U.S. Department of Energy (DOE) Order 435.1 (DOE, 2001) requiresmore » that radioactive waste be managed in a manner that protects public health and safety, and the environment. To comply with this order, DOE field sites must prepare and maintain site-specific radiological performance assessments for LLW disposal facilities that accept waste after September 26, 1988. Furthermore, sites are required to conduct composite analyses that account for the cumulative impacts of all waste that has been (or will be) disposed of at the facilities and other sources of radioactive material that may interact with the facilities. Revision 4 of the Area G performance assessment and composite analysis was issued in 2008 (LANL, 2008). These analyses estimate rates of radionuclide release from the waste disposed of at the facility, simulate the movement of radionuclides through the environment, and project potential radiation doses to humans for several on-site and off-site exposure scenarios. The assessments are based on existing site and disposal facility data and on assumptions about future rates and methods of waste disposal. The accuracy of the performance assessment and composite analysis depends upon the validity of the data used and assumptions made in conducting the analyses. If changes in these data and assumptions are significant, they may invalidate

  15. Correspondence between maternal determination of child fullness and young children's self-determined fullness level: Results from a standardized laboratory protocol

    USDA-ARS?s Scientific Manuscript database

    This study examined maternal understanding and acceptance of young children's ability to self-assess fullness using a mixed-methods approach. Twenty low-income mothers of 5- to 7-year-olds participated in this semistructured laboratory study. After consumption of a buffet dinner meal, mothers were a...

  16. Tritium concentrations in flow from selected springs that discharge to the Snake River, Twin Falls-Hagerman area, Idaho

    USGS Publications Warehouse

    Mann, L.J.

    1989-01-01

    Concern has been expressed that some of the approximately 30,900 curies of tritium disposed to the Snake River Plain aquifer from 1952 to 1988 at the INEL (Idaho National Engineering Laboratory) have migrated to springs discharging to the Snake River in the Twin Falls-Hagerman area. To document tritium concentrations in springflow, 17 springs were sampled in November 1988 and 19 springs were sampled in March 1989. Tritium concentrations were less than the minimum detectable concentration of 0.5 pCi/mL (picocuries/mL) in November 1988 and less than the minimum detectable concentration of 0.2 pCi/mL in March 1989; the minimum detectable concentration was smaller in March 1989 owing to a longer counting time in the liquid scintillation system. The maximum contaminant level of tritium in drinking water as established by the U.S. Environmental Protection Agency is 20 pCi/mL. U.S. Environmental Protection Agency sample analyses indicate that the tritium concentration has decreased in the Snake River near Buhl since the 1970's. In 1974-79, tritium concentrations were less than 0.3 +/-0.2 pCi/mL in 3 of 20 samples; in 1983-88, 17 of 23 samples contained less than 0.3 +/-0.2 pCi/mL of tritium; the minimum detectable concentration is 0.2 pCi/mL. On the basis of decreasing tritium concentrations in the Snake River, their correlation to cessation of atmospheric weapons tests tritium concentrations in springflow less than the minimum detectable concentration, and the distribution of tritium in groundwater at the INEL, aqueous disposal of tritium at the INEL has had no measurable effect on tritium concentrations in springflow from the Snake River Plain aquifer and in the Snake River near Buhl. (USGS)

  17. SUBGRADE MONOLITHIC ENCASEMENT STABILIZATION OF CATEGORY 3 LOW LEVEL WASTE (LLW)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    PHILLIPS, S.J.

    2004-02-03

    A highly efficient and effective technology has been developed and is being used for stabilization of Hazard Category 3 low-level waste at the U.S. Department of Energy's Hanford Site. Using large, structurally interconnected monoliths, which form one large monolith that fills a waste disposal trench, the patented technology can be used for final internment of almost any hazardous, radioactive, or toxic waste or combinations of these waste materials packaged in a variety of sizes, shapes, and volumes within governmental regulatory limits. The technology increases waste volumetric loading by 100 percent, area use efficiency by 200 percent, and volumetric configuration efficiencymore » by more than 500 percent over past practices. To date, in excess of 2,010 m{sup 3} of contact-handled and remote-handled low-level radioactive waste have been interned using this patented technology. Additionally, in excess of 120 m{sup 3} of low-level radioactive waste requiring stabilization in low-diffusion coefficient waste encasement matrix has been disposed using this technology. Greater than five orders of magnitude in radiation exposure reduction have been noted using this method of encasement of Hazard Category 3 waste. Additionally, exposure monitored at all monolith locations produced by the slip form technology is less than 1.29 x E-07 C {center_dot} kg{sup -1}. Monolithic encasement of Hazard Category 3 low-level waste and other waste category materials may be successfully accomplished using this technology at nominally any governmental or private sector waste disposal facility. Additionally, other waste materials consisting of hazardous, radioactive, toxic, or mixed waste materials can be disposed of using the monolithic slip form encasement technology.« less

  18. Low Reactive Level Laser Therapy for Mesenchymal Stromal Cells Therapies

    PubMed Central

    Kushibiki, Toshihiro; Hirasawa, Takeshi; Okawa, Shinpei; Ishihara, Miya

    2015-01-01

    Low reactive level laser therapy (LLLT) is mainly focused on the activation of intracellular or extracellular chromophore and the initiation of cellular signaling by using low power lasers. Over the past forty years, it was realized that the laser therapy had the potential to improve wound healing and reduce pain and inflammation. In recent years, the term LLLT has become widely recognized in the field of regenerative medicine. In this review, we will describe the mechanisms of action of LLLT at a cellular level and introduce the application to mesenchymal stem cells and mesenchymal stromal cells (MSCs) therapies. Finally, our recent research results that LLLT enhanced the MSCs differentiation to osteoblast will also be described. PMID:26273309

  19. Effective low-level processing for interferometric image enhancement

    NASA Astrophysics Data System (ADS)

    Joo, Wonjong; Cha, Soyoung S.

    1995-09-01

    The hybrid operation of digital image processing and a knowledge-based AI system has been recognized as a desirable approach of the automated evaluation of noise-ridden interferogram. Early noise/data reduction before phase is extracted is essential for the success of the knowledge- based processing. In this paper, new concepts of effective, interactive low-level processing operators: that is, a background-matched filter and a directional-smoothing filter, are developed and tested with transonic aerodynamic interferograms. The results indicate that these new operators have promising advantages in noise/data reduction over the conventional ones, leading success of the high-level, intelligent phase extraction.

  20. Threshold level or not for low-density lipoprotein cholesterol.

    PubMed

    Barter, P J; Sacks, F M

    2001-05-01

    As drugs, such as the statins, and other therapies demonstrate the ability to significantly lower levels of low-density lipoprotein cholesterol (LDL-C), one issue is whether there is a lower threshold below which no further decline in coronary heart disease occurs. Those who evaluate the data from multiple trials and conclude that no significant decrease in coronary event rates occurs at or below 125 mg/dL suggest using this level as a guideline for clinical application of cholesterol-lowering therapy. On the other hand, analysis of the results of the same population and primary prevention studies concludes that no such threshold exists. The issues affected by the decision of whether to use a threshold include costs to the healthcare system for additional physician time, tests, and medication; unknown clinical events and safety related to very low LDL-C; and resource prioritization to an unestablished therapeutic approach.

  1. Laboratory studies on low-energy electron penetration depths into amorphous ice - consequence to astrobiology on icy surfaces

    NASA Astrophysics Data System (ADS)

    Gudipati, M. S.; Li, I.; Lignell, A. A.

    2009-12-01

    Penetration of electrons through icy surfaces plays an important role in radiation processing of solar system icy bodies. However, to date, there is no quantitative data available on the penetration depths of electrons through cryogenic water-ices. Penetration of high-energy incident electrons also results in the in-situ formation of secondary low-energy electrons, such as on the surface of Europa (Herring-Captain et al., 2005; Johnson et al., 2004). Low-energy electrons can also be produced through photoionization process such as on comet surfaces, or through bombardment by solar wind on icy surfaces (Bodewits et al., 2004). Present models use the laboratory penetration data of high-energy (>10 keV) electrons through silicon as a proxy for the ice (Cooper et al., 2001), normalized by the density of the medium. So far no laboratory studies have been conducted that deal with the penetration of electrons through amorphous or crystalline ices. In order to address this issue, we adopted a new experimental strategy by using aromatic molecules as probes. To begin with, we carried out systematic studies on the penetration depths of low-energy electrons (5 eV - 2 keV) through amorphous ice films of defined thickness at cryogenic temperatures (5 - 30 K). The results of these experiments will be analyzed and their relevance to survival of organic material on solar system icy surfaces will be presented. References: Bodewits, D., et al., 2004. X-ray and Far-Ultraviolet emission from comets: Relevant charge exchange processes. Physica Scripta. 70, C17-C20. Cooper, J. F., et al., 2001. Energetic ion and electron irradiation of the icy Galilean satellites. Icarus. 149, 133-159. Herring-Captain, J., et al., 2005. Low-energy (5-250 eV) electron-stimulated desorption of H+, H2+, and H+(H2O)nfrom low-temperature water ice surfaces. Physical Review B. 72, 035431-10. Johnson, R. E., et al., Radiation Effects on the Surfaces of the Galilean Satellites. In: F. Bagenal, et al., Eds

  2. Improving low-level plasma protein mass spectrometry-based detection for candidate biomarker discovery and validation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Page, Jason S.; Kelly, Ryan T.; Camp, David G.

    2008-09-01

    Methods. To improve the detection of low abundance protein candidate biomarker discovery and validation, particularly in complex biological fluids such as blood plasma, increased sensitivity is desired using mass spectrometry (MS)-based instrumentation. A key current limitation on the sensitivity of electrospray ionization (ESI) MS is due to the fact that many sample molecules in solution are never ionized, and the vast majority of the ions that are created are lost during transmission from atmospheric pressure to the low pressure region of the mass analyzer. Two key technologies, multi-nanoelectrospray emitters and the electrodynamic ion funnel have recently been developed and refinedmore » at Pacific Northwest National Laboratory (PNNL) to greatly improve the ionization and transmission efficiency of ESI MS based analyses. Multi-emitter based ESI enables the flow from a single source (typically a liquid chromatography [LC] column) to be divided among an array of emitters (Figure 1). The flow rate delivered to each emitter is thus reduced, allowing the well-documented benefits of nanoelectrospray 1 for both sensitivity and quantitation to be realized for higher flow rate separations. To complement the increased ionization efficiency afforded by multi-ESI, tandem electrodynamic ion funnels have also been developed at PNNL, and shown to greatly improve ion transmission efficiency in the ion source interface.2, 3 These technologies have been integrated into a triple quadrupole mass spectrometer for multiple reaction monitoring (MRM) of probable biomarker candidates in blood plasma and show promise for the identification of new species even at low level concentrations.« less

  3. Lid design for low level waste container

    DOEpatents

    Holbrook, Richard H.; Keener, Wendell E.

    1995-01-01

    A container for low level waste includes a shell and a lid. The lid has a frame to which a planar member is welded. The lid frame includes a rectangular outer portion made of square metal tubing, a longitudinal beam extending between axial ends of the rectangular outer portion, and a transverse beam extending between opposite lateral sides of the rectangular outer portion. Two pairs of diagonal braces extend between the longitudinal beam and the four corners of the rectangular outer portion of the frame.

  4. Lid design for low level waste container

    DOEpatents

    Holbrook, R.H.; Keener, W.E.

    1995-02-28

    A container for low level waste includes a shell and a lid. The lid has a frame to which a planar member is welded. The lid frame includes a rectangular outer portion made of square metal tubing, a longitudinal beam extending between axial ends of the rectangular outer portion, and a transverse beam extending between opposite lateral sides of the rectangular outer portion. Two pairs of diagonal braces extend between the longitudinal beam and the four corners of the rectangular outer portion of the frame. 6 figs.

  5. Environmental analysis burial of offsite low-level waste at SRP

    NASA Astrophysics Data System (ADS)

    Poe, W. L.; Moyer, R. A.

    1980-12-01

    The environmental effects of receipt and burial of low level naval waste are assessed. This low level waste was sent to the NRC-licensed burial ground operated by Chem-Nuclear Systems, Inc., at Barnwell, South Carolina. The DOE announced that DOE-generated low level waste would no longer be buried at commercial waste burial sites. The SRP was selected to receive the Naval waste described in this analysis. Receipt and burial of these wastes will have a negligible effect on SRP's environment and increase only sightly the environmental effects of the SRP operations discussed in the EIS on SRP waste management operations. The environmental effects of burial of this waste at Chem-Nuclear Burial Ground or at the SRP Burial Ground are described in this environmental analysis to permit assessment of incremental effects caused by the decision to bury this Naval waste in the SRP Burial Ground rather than in the Barnwell Burial Ground. The radiological effects from burial of this waste in either the SRP or Chem-Nuclear Burial Ground are very small when compared to those from natural background radiation or to the annual population dose commitment from operation of SRP. The environmental effects of burial at SRP to dose commitments normally received by the population surrounding SRP are compared.

  6. Preoperative Low Serum Bicarbonate Levels Predict Acute Kidney Injury After Cardiac Surgery.

    PubMed

    Jung, Su-Young; Park, Jung Tak; Kwon, Young Eun; Kim, Hyung Woo; Ryu, Geun Woo; Lee, Sul A; Park, Seohyun; Jhee, Jong Hyun; Oh, Hyung Jung; Han, Seung Hyeok; Yoo, Tae-Hyun; Kang, Shin-Wook

    2016-03-01

    Acute kidney injury (AKI) after cardiac surgery is a common and serious complication. Although lower than normal serum bicarbonate levels are known to be associated with consecutive renal function deterioration in patients with chronic kidney injury, it is not well-known whether preoperative low serum bicarbonate levels are associated with the development of AKI in patients who undergo cardiac surgery. Therefore, the clinical implication of preoperative serum bicarbonate levels on AKI occurrence after cardiac surgery was investigated. Patients who underwent coronary artery bypass or valve surgery at Yonsei University Health System from January 2013 to December 2014 were enrolled. The patients were divided into 3 groups based on preoperative serum bicarbonate levels, which represented group 1 (below normal levels) <23 mEq/L; group 2 (normal levels) 23 to 24 mEq/L; and group 3 (elevated levels) >24 mEq/L. The primary outcome was the predicated incidence of AKI 48 hours after cardiac surgery. AKI was defined according to Acute Kidney Injury Network criteria. Among 875 patients, 228 (26.1%) developed AKI within 48 hours after cardiac surgery. The incidence of AKI was higher in group 1 (40.9%) than in group 2 (26.5%) and group 3 (19.5%) (P < 0.001). In addition, the duration of postoperative stay in a hospital intensive care unit (ICU) was longer for AKI patients and for those in the low-preoperative-serum-bicarbonate-level groups. A multivariate logistic regression analysis showed that low preoperative serum bicarbonate levels were significantly associated with AKI even after adjustment for age, sex, hypertension, diabetes mellitus, operation type, preoperative hemoglobin, and estimated glomerular filtration rate. In conclusion, low serum bicarbonate levels were associated with higher incidence of AKI and prolonged ICU stay. Further studies are needed to clarify whether strict correction of bicarbonate levels close to normal limits may have a protective

  7. Low-level radioactive waste technology: a selected, annotated bibliography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fore, C.S.; Vaughan, N.D.; Hyder, L.K.

    1980-10-01

    This annotated bibliography of 447 references contains scientific, technical, economic, and regulatory information relevant to low-level radioactive waste technology. The bibliography focuses on environmental transport, disposal site, and waste treatment studies. The publication covers both domestic and foreign literature for the period 1952 to 1979. Major chapters selected are Chemical and Physical Aspects; Container Design and Performance; Disposal Site; Environmental Transport; General Studies and Reviews; Geology, Hydrology and Site Resources; Regulatory and Economic Aspects; Transportation Technology; Waste Production; and Waste Treatment. Specialized data fields have been incorporated into the data file to improve the ease and accuracy of locating pertinentmore » references. Specific radionuclides for which data are presented are listed in the Measured Radionuclides field, and specific parameters which affect the migration of these radionuclides are presented in the Measured Parameters field. In addition, each document referenced in this bibliography has been assigned a relevance number to facilitate sorting the documents according to their pertinence to low-level radioactive waste technology. The documents are rated 1, 2, 3, or 4, with 1 indicating direct applicability to low-level radioactive waste technology and 4 indicating that a considerable amount of interpretation is required for the information presented to be applied. The references within each chapter are arranged alphabetically by leading author, corporate affiliation, or title of the document. Indexes are provide for (1) author(s), (2) keywords, (3) subject category, (4) title, (5) geographic location, (6) measured parameters, (7) measured radionuclides, and (8) publication description.« less

  8. Cardiovascular Reactivity in Patients With Major Depressive Disorder With High- or Low-Level Depressive Symptoms: A Cross-Sectional Comparison of Cardiovascular Reactivity to Laboratory-Induced Mental Stress.

    PubMed

    Wang, Mei-Yeh; Chiu, Chen-Huan; Lee, Hsin-Chien; Su, Chien-Tien; Tsai, Pei-Shan

    2016-03-01

    Depression increases the risk of adverse cardiac events. Cardiovascular reactivity is defined as the pattern of cardiovascular responses to mental stress. An altered pattern of cardiovascular reactivity is an indicator of subsequent cardiovascular disease. Because depression and adverse cardiac events may have a dose-dependent association, this study examined the differences in cardiovascular reactivity to mental stress between patients with major depressive disorder (MDD) with high depression levels and those with low depression levels. Moreover, autonomic nervous system regulation is a highly plausible biological mechanism for the pattern of cardiovascular reactivity to mental stress. The association between cardiovascular reactivity and parameters of heart rate variability (HRV), an index for quantifying autonomic nervous system activity modulation, was thus examined. This study included 88 patients with MDD. HRV was measured before stress induction. The Stroop Color and Word Test and mirror star-tracing task were used to induce mental stress. We observed no significant association between depressive symptom level and any of the cardiovascular reactivity parameters. Cardiovascular reactivity to mental stress was comparable between patients with MDD with high-level depressive symptoms and those with low-level depressive symptoms. After adjusting for confounding variables, the high-frequency domain of HRV was found to be an independent predictor of the magnitude of heart rate reactivity (β = -.33, p = .002). In conclusion, the magnitude of cardiovascular reactivity may be independent of depression severity in patients with MDD. The autonomic regulation of cardiovascular responses to mental stress primarily influences heart rate reactivity in patients with MDD. © The Author(s) 2015.

  9. Bat habitat research. Final technical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keller, B.L.; Bosworth, W.R.; Doering, R.W.

    This progress report describes activities over the current reporting period to characterize the habitats of bats on the INEL. Research tasks are entitled Monitoring bat habitation of caves on the INEL to determine species present, numbers, and seasons of use; Monitor bat use of man-made ponds at the INEL to determine species present and rates of use of these waters; If the Big Lost River is flowing on the INEL and/or if the Big Lost River sinks contain water, determine species present, numbers and seasons of use; Determine the habitat requirement of Townsend`s big-eared bats, including the microclimate of cavesmore » containing Townsend`s big-eared bats as compared to other caves that do not contain bats; Determine and describe an economical and efficient bat census technique to be used periodically by INEL scientists to determine the status of bats on the INEL; and Provide a suggestive management and protective plan for bat species on the INEL that might, in the future, be added to the endangered and sensitive list;« less

  10. Comparing the occlusal contact area of individual teeth during low-level clenching.

    PubMed

    Nishimori, Hideta; Iida, Takashi; Kamiyama, Hirona; Komoda, Yoshihiro; Obara, Ryoko; Uchida, Takashi; Kawara, Misao; Komiyama, Osamu

    2017-09-14

    The aim of this study was to investigate the occlusal contact area (OCA) in individual teeth during low-level tooth clenching in 24 healthy participants. Before measurements were made, the 100% maximum voluntary contraction (MVC) was determined. At baseline, all subjects were instructed to close their mouth and touch the opposing teeth with minimal force. Occlusal contact was recorded during three jaw motor tasks (baseline, 20% MVC, and 40% MVC) using a blue silicone material. OCA thickness was determined from images and defined on five levels: level 1 (0-149 µm), level 2 (0-89 µm), level 3 (0-49 µm), level 4 (0-29 µm), and level 5 (0-4 µm). Premolar and molar OCAs increased significantly from baseline to 20% MVC and 40% MVC. The OCA of each anterior tooth did not change significantly with increasing clenching intensity at all levels. Our findings suggest that premolar and molar OCAs may be altered by low-intensity clenching, affecting the teeth and periodontal tissues.

  11. Low-level therapy in ophthalmology

    NASA Astrophysics Data System (ADS)

    Pankov, O. P.

    1999-07-01

    Extremely slow introduction of low-level laser therapy into the practice of ophthalmologists is restricted by the lack of good methodological recommendation and modern equipment adopted to the needs of ophthalmology. The most perspective is considered to be further improvement of the methods and the elaboration of the medical equipment, working in several wave bands, combined with magnetotherapy and working with the use of various modes of the modulation of the intensity of the luminous flux. It may be asserted that unlike the mode of continuous radiation, in some cases, the effectiveness of the treatment increases when the modulated light with the frequency of one to a few tens HZ is used. Moreover, the methods are being elaborated, when the modulation frequency of laser light and the biorhythms of man physiologic parameters are synchronized. Very perspective seems the computerization of the treatment process with the simultaneous electrophysiological control of the condition of visual functions.

  12. Low Levels of Evidence on the Plastic Surgery In-Service Training Exam.

    PubMed

    Silvestre, Jason; Bilici, Nadir; Serletti, Joseph M; Chang, Benjamin

    2016-06-01

    The Plastic Surgery In-Service Training Exam is written by the American Society of Plastic Surgeons. Examinees reasonably infer that tested material reflects the Society's vision for the core curriculum in plastic surgery. The purpose of this study was to determine the levels of evidence on which credited answers to the examination questions are based. Two recent Plastic Surgery In-Service Training Exams (2014 and 2015) were analyzed. Questions were categorized using a taxonomy model. Recommended journal article references for Level III (decision-making) questions were assigned a level of evidence. Exam sections were analyzed for differences in question taxonomy distribution and level of evidence. To look for studies with higher levels of evidence, a PubMed search was conducted for a random sample of 10 questions from each section. One hundred three Level I (25.8 percent), 138 Level II (34.5 percent), and 159 Level III (39.8 percent) questions were analyzed (p < 0.001). The hand and lower extremity section had the highest percentage of Level III questions (50.0 percent; p = 0.005). Journal articles had a mean level of evidence of 3.9 ± 0.7. The number of articles with a low level of evidence (IV and V) (p = 0.624) and the percentage of questions supported by articles with a high level of evidence (I and II) (p = 0.406) did not vary by section. The PubMed search revealed no instances of a higher level of evidence than the recommended reading list. A significant percentage of Plastic Surgery In-Service Training Exam questions test clinical management, but most are supported with a low level of evidence. Although that is consistent with low level of evidence of plastic surgery literature, educators should recognize the potential for biases of question writers.

  13. A Note on Comparing the Power of Test Statistics at Low Significance Levels.

    PubMed

    Morris, Nathan; Elston, Robert

    2011-01-01

    It is an obvious fact that the power of a test statistic is dependent upon the significance (alpha) level at which the test is performed. It is perhaps a less obvious fact that the relative performance of two statistics in terms of power is also a function of the alpha level. Through numerous personal discussions, we have noted that even some competent statisticians have the mistaken intuition that relative power comparisons at traditional levels such as α = 0.05 will be roughly similar to relative power comparisons at very low levels, such as the level α = 5 × 10 -8 , which is commonly used in genome-wide association studies. In this brief note, we demonstrate that this notion is in fact quite wrong, especially with respect to comparing tests with differing degrees of freedom. In fact, at very low alpha levels the cost of additional degrees of freedom is often comparatively low. Thus we recommend that statisticians exercise caution when interpreting the results of power comparison studies which use alpha levels that will not be used in practice.

  14. LOW-LEVEL CARBON MONOXIDE EXPOSURE AND WORK CAPACITY AT 1600 METERS

    EPA Science Inventory

    At sea level, low-level carbon monoxide (CO) exposure impairs exercise performance. To determine if altitude residence at 1600 m augments this CO effect, two studies of graded treadmill work capacity were done. The Initial Study investigated nine, non-smoking male subjects breath...

  15. Do low oxygen environments facilitate marine invasions? Relative tolerance of native and invasive species to low oxygen conditions.

    PubMed

    Lagos, Marcelo E; Barneche, Diego R; White, Craig R; Marshall, Dustin J

    2017-06-01

    Biological invasions are one of the biggest threats to global biodiversity. Marine artificial structures are proliferating worldwide and provide a haven for marine invasive species. Such structures disrupt local hydrodynamics, which can lead to the formation of oxygen-depleted microsites. The extent to which native fauna can cope with such low oxygen conditions, and whether invasive species, long associated with artificial structures in flow-restricted habitats, have adapted to these conditions remains unclear. We measured water flow and oxygen availability in marinas and piers at the scales relevant to sessile marine invertebrates (mm). We then measured the capacity of invasive and native marine invertebrates to maintain metabolic rates under decreasing levels of oxygen using standard laboratory assays. We found that marinas reduce water flow relative to piers, and that local oxygen levels can be zero in low flow conditions. We also found that for species with erect growth forms, invasive species can tolerate much lower levels of oxygen relative to native species. Integrating the field and laboratory data showed that up to 30% of available microhabitats within low flow environments are physiologically stressful for native species, while only 18% of the same habitat is physiologically stressful for invasive species. These results suggest that invasive species have adapted to low oxygen habitats associated with manmade habitats, and artificial structures may be creating niche opportunities for invasive species. © 2017 John Wiley & Sons Ltd.

  16. Impact of maternal education level on risk of low Apgar score.

    PubMed

    Almeida, N K O; Pedreira, C E; Almeida, R M V R

    2016-11-01

    To investigate the association between 5-min Apgar score and socio-economic characteristics of pregnant women, particularly education level. Population-based cross-sectional study. This study used hospital records of live term singleton births in Brazil from 2004 to 2009, obtained from the Ministry of Health National Information System. Crude and adjusted odds ratios (ORs) were used to estimate the risk of a low 5-min Apgar score (≤6) associated with maternal education level, maternal age, marital status, primiparity, number of prenatal visits and mode of delivery (vaginal/caesarean section). Nearly 12 million records were analysed. Births from mothers with 0, 1-3, 4-7 and 8-11 years of education resulted in crude ORs for low 5-min Apgar score of 3.1, 2.2, 1.8 and 1.3, respectively (reference: ≥12 years of education). The crude OR for mothers aged ≥41 years (reference 21-34 years) was 1.4, but no risk was detected for those with ≥12 years of education and those who gave birth by caesarean section (OR 1.0 [95% confidence interval 0.9-1.2]). Generally, the risk of a low 5-min Apgar score was found to increase as maternal age moved away from 21 to 34 years (OR 1.1-1.7), and for mothers with the same characteristics, the risk of a low 5-min Apgar score was found to decrease markedly as education level increased (adjusted OR decreased from 2.6 to 1.2). Maternal education level is clearly associated with the risk of a low 5-min Apgar score. Copyright © 2016 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  17. Comparison of species-level identification and antifungal susceptibility results from diagnostic and reference laboratories for bloodstream Candida surveillance isolates, South Africa, 2009-2010.

    PubMed

    Naicker, Serisha D; Govender, Nevashan; Patel, Jaymati; Zietsman, Inge L; Wadula, Jeannette; Coovadia, Yacoob; Kularatne, Ranmini; Seetharam, Sharona; Govender, Nelesh P

    2016-11-01

    From February 2009 through August 2010, we compared species-level identification of bloodstream Candida isolates and susceptibility to fluconazole, voriconazole, and caspofungin between diagnostic and reference South African laboratories during national surveillance for candidemia. Diagnostic laboratories identified isolates to genus/species level and performed antifungal susceptibility testing, as indicated. At a reference laboratory, viable Candida isolates were identified to species-level using automated systems, biochemical tests, or DNA sequencing; broth dilution susceptibility testing was performed. Categorical agreement (CA) was calculated for susceptibility results of isolates with concordant species identification. Overall, 2172 incident cases were detected, 773 (36%) by surveillance audit. The Vitek 2 YST system (bioMérieux Inc, Marcy l'Etoile, France) was used for identification (360/863, 42%) and susceptibility testing (198/473, 42%) of a large proportion of isolates. For the five most common species (n = 1181), species-level identification was identical in the majority of cases (Candida albicans: 98% (507/517); Candida parapsilosis: 92% (450/488); Candida glabrata: 89% (89/100); Candida tropicalis: 91% (49/54), and Candida krusei: 86% (19/22)). However, diagnostic laboratories were significantly less likely to correctly identify Candida species other than C. albicans versus C. albicans (607/664, 91% vs. 507/517, 98%; P < .001). Susceptibility data were compared for isolates belonging to the five most common species and fluconazole, voriconazole, and caspofungin in 860, 580, and 99 cases, respectively. Diagnostic laboratories significantly under-reported fluconazole resistance in C. parapsilosis (225/393, 57% vs. 239/393, 61%; P < .001) but over-reported fluconazole non-susceptibility in C. albicans (36/362, 10% vs. 3/362, 0.8%; P < .001). Diagnostic laboratories were less likely to correctly identify Candida species other than C. albicans, under

  18. National low-level waste management program radionuclide report series, Volume 15: Uranium-238

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adams, J.P.

    1995-09-01

    This report, Volume 15 of the National Low-Level Waste Management Program Radionuclide Report Series, discusses the radiological and chemical characteristics of uranium-238 ({sup 238}U). The purpose of the National Low-Level Waste Management Program Radionuclide Report Series is to provide information to state representatives and developers of low-level radioactive waste disposal facilities about the radiological, chemical, and physical characteristics of selected radionuclides and their behavior in the waste disposal facility environment. This report also includes discussions about waste types and forms in which {sup 238}U can be found, and {sup 238}U behavior in the environment and in the human body.

  19. A virtual laboratory for the simulation of sustainable energy systems in a low energy building: A case study

    NASA Astrophysics Data System (ADS)

    Breen, M.; O'Donovan, A.; Murphy, M. D.; Delaney, F.; Hill, M.; Sullivan, P. D. O.

    2016-03-01

    The aim of this paper was to develop a virtual laboratory simulation platform of the National Building Retrofit Test-bed at the Cork Institute of Technology, Ireland. The building in question is a low-energy retrofit which is provided with electricity by renewable systems including photovoltaics and wind. It can be thought of as a living laboratory, as a number of internal and external building factors are recorded at regular intervals during human occupation. The analysis carried out in this paper demonstrated that, for the period from April to September 2015, the electricity provided by the renewable systems did not consistently match the building’s electricity requirements due to differing load profiles. It was concluded that the use of load shifting techniques may help to increase the percentage of renewable energy utilisation.

  20. Technology Being Developed at Lawrence Berkeley National Laboratory: Ultra-Low- Emission Combustion Technologies for Heat and Power Generation

    NASA Technical Reports Server (NTRS)

    Cheng, Robert K.

    2001-01-01

    The Combustion Technologies Group at Lawrence Berkeley National Laboratory has developed simple, low-cost, yet robust combustion technologies that may change the fundamental design concept of burners for boilers and furnaces, and injectors for gas turbine combustors. The new technologies utilize lean premixed combustion and could bring about significant pollution reductions from commercial and industrial combustion processes and may also improve efficiency. The technologies are spinoffs of two fundamental research projects: An inner-ring burner insert for lean flame stabilization developed for NASA- sponsored reduced-gravity combustion experiments. A low-swirl burner developed for Department of Energy Basic Energy Sciences research on turbulent combustion.

  1. Challenges of Maintaining Good Clinical Laboratory Practices in Low-Resource Settings:  A Health Program Evaluation Framework Case Study From East Africa.

    PubMed

    Zhang, Helen L; Omondi, Michael W; Musyoka, Augustine M; Afwamba, Isaac A; Swai, Remigi P; Karia, Francis P; Muiruri, Charles; Reddy, Elizabeth A; Crump, John A; Rubach, Matthew P

    2016-08-01

    Using a clinical research laboratory as a case study, we sought to characterize barriers to maintaining Good Clinical Laboratory Practice (GCLP) services in a developing world setting. Using a US Centers for Disease Control and Prevention framework for program evaluation in public health, we performed an evaluation of the Kilimanjaro Christian Medical Centre-Duke University Health Collaboration clinical research laboratory sections of the Kilimanjaro Clinical Research Institute in Moshi, Tanzania. Laboratory records from November 2012 through October 2014 were reviewed for this analysis. During the 2-year period of study, seven instrument malfunctions suspended testing required for open clinical trials. A median (range) of 9 (1-55) days elapsed between instrument malfunction and biomedical engineer service. Sixteen (76.1%) of 21 suppliers of reagents, controls, and consumables were based outside Tanzania. Test throughput among laboratory sections used a median (range) of 0.6% (0.2%-2.7%) of instrument capacity. Five (55.6%) of nine laboratory technologists left their posts over 2 years. These findings demonstrate that GCLP laboratory service provision in this setting is hampered by delays in biomedical engineer support, delays and extra costs in commodity procurement, low testing throughput, and high personnel turnover. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  2. A Task-Dependent Causal Role for Low-Level Visual Processes in Spoken Word Comprehension

    ERIC Educational Resources Information Center

    Ostarek, Markus; Huettig, Falk

    2017-01-01

    It is well established that the comprehension of spoken words referring to object concepts relies on high-level visual areas in the ventral stream that build increasingly abstract representations. It is much less clear whether basic low-level visual representations are also involved. Here we asked in what task situations low-level visual…

  3. Managing the Occupational Education Laboratory.

    ERIC Educational Resources Information Center

    Storm, George

    This guide for occupational educators deals with laboratory and instructional management on an interdisciplinary basis within the broad field of occupational education. The principles discussed are intended to be applied at all levels and in all types of laboratories. The text suggests effective ways of organizing laboratories so that students can…

  4. Taiwan industrial cooperation program technology transfer for low-level radioactive waste final disposal - phase I.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knowlton, Robert G.; Cochran, John Russell; Arnold, Bill Walter

    2007-01-01

    Sandia National Laboratories and the Institute of Nuclear Energy Research, Taiwan have collaborated in a technology transfer program related to low-level radioactive waste (LLW) disposal in Taiwan. Phase I of this program included regulatory analysis of LLW final disposal, development of LLW disposal performance assessment capabilities, and preliminary performance assessments of two potential disposal sites. Performance objectives were based on regulations in Taiwan and comparisons to those in the United States. Probabilistic performance assessment models were constructed based on limited site data using software including GoldSim, BLT-MS, FEHM, and HELP. These software codes provided the probabilistic framework, container degradation, waste-formmore » leaching, groundwater flow, radionuclide transport, and cover infiltration simulation capabilities in the performance assessment. Preliminary performance assessment analyses were conducted for a near-surface disposal system and a mined cavern disposal system at two representative sites in Taiwan. Results of example calculations indicate peak simulated concentrations to a receptor within a few hundred years of LLW disposal, primarily from highly soluble, non-sorbing radionuclides.« less

  5. Airport low-level wind shear lidar observation at beijing capital international airport

    NASA Astrophysics Data System (ADS)

    Zhang, Hongwei; Wu, Songhua; Wang, Qichao; Liu, Bingyi; Zhai, Xiaochun

    2018-04-01

    Ocean University of China lidar team operated a pulse coherent Doppler lidar (PCDL) for the low level wind shear monitoring at the Beijing Capital International Airport (BCIA) in 2015. The experiment configuration, observation modes is presented. A case study shows that the low level wind shear events at the southern end of 18R/36L runway were mainly caused by the trees and buildings along the glide path under strong northwest wind conditions.

  6. Using compressive measurement to obtain images at ultra low-light-level

    NASA Astrophysics Data System (ADS)

    Ke, Jun; Wei, Ping

    2013-08-01

    In this paper, a compressive imaging architecture is used for ultra low-light-level imaging. In such a system, features, instead of object pixels, are imaged onto a photocathode, and then magnified by an image intensifier. By doing so, system measurement SNR is increased significantly. Therefore, the new system can image objects at ultra low-ligh-level, while a conventional system has difficulty. PCA projection is used to collect feature measurements in this work. Linear Wiener operator and nonlinear method based on FoE model are used to reconstruct objects. Root mean square error (RMSE) is used to quantify system reconstruction quality.

  7. Forearm Muscle Oxygenation Decreases During Low Levels of Brief, Isometric Contraction

    NASA Technical Reports Server (NTRS)

    Murthy Gita; Kahan, N. J.; Hargens, Alan R.; Rempel, D. M.; Hargens, Murthy G. (Technical Monitor)

    1997-01-01

    Regional muscle pain syndromes can be caused by repeated and sustained exertion of a specific muscle. Such exertion may elevate local tissue fluid pressure, reduce blood flow and tissue oxygenation (TO2), and cause fatigue, pain and functional deficits of the Involved muscle. Low levels (less than 20% maximum voluntary contraction (MVC)) of prolonged static contraction of the upper extremity are common In many occupational settings and May cause fatigue. The purpose of our Investigation was to determine whether TO2 decreases significantly at low levels of static contraction of the extensor carpi radialis brevis (ECRB).

  8. Low maternal melatonin level increases autism spectrum disorder risk in children.

    PubMed

    Braam, Wiebe; Ehrhart, Friederike; Maas, Anneke P H M; Smits, Marcel G; Curfs, Leopold

    2018-02-28

    It is assumed that autism spectrum disorder (ASD) is caused by a combination of de novo inherited variation and common variation as well as environmental factors. It often co-occurs with intellectual disability (ID). Almost eight hundred potential causative genetic variations have been found in ASD patients. However, not one of them is responsible for more than 1% of ASD cases. Low melatonin levels are a frequent finding in ASD patients. Melatonin levels are negatively correlated with severity of autistic impairments, it is important for normal neurodevelopment and is highly effective in protecting DNA from oxidative damage. Melatonin deficiency could be a major factor, and well a common heritable variation, that increases the susceptibility to environmental risk factors for ASD. ASD is already present at birth. As the fetus does not produce melatonin, low maternal melatonin levels may be involved. We measured 6-sulfatoxymelatonin in urine of 60 mothers of a child with ASD and controls. 6-sulfatoxymelatonin levels were significantly lower in mothers with an ASD child than in controls (p = 0.012). Low parental melatonin levels could be one of the contributors to ASD and possibly ID etiology. Our findings need to be duplicated on a larger scale. If our hypothesis is correct, this could lead to policies to detect future parents who are at risk and to treatment strategies to ASD and intellectual disability risk. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Low Background Levels of Mars Methane at Gale Crater Indicate Seasonal Cycle: Updated Results from TLS-SAM on Curiosity

    NASA Astrophysics Data System (ADS)

    Webster, C. R.; Mahaffy, P. R.; Atreya, S. K.

    2016-12-01

    In situ measurements of atmospheric methane have been made over a 3-year period at Gale Crater on Mars using the Tunable Laser Spectrometer (TLS) instrument in the Sample Analysis at Mars (SAM) suite on the Curiosity rover. We have reported two important observations: (i) a background level of 0.5 ppbv that is about five times lower than some model predictions based on generation from UV degradation of micro-meteorites or interplanetary dust delivered to the martian surface; (ii) a "spike" of elevated levels of 7 ppbv that were seen1 on four sequential observations over a 2-month period before dropping to background levels. This spike was attributed to an episodic release from a small local source, probably to the north of Gale crater. While the elevated levels of the spike did not return (repeat) one Mars year later, we have seen what appears to be a seasonal variation to the background levels that are all < 1ppbv. The variation ranges from a low of 0.2 ppbv in the northern hemisphere spring to 0.9 ppbv in the northern hemisphere late summer, a change in mixing ratio over a range larger than expected from our current understanding of methane sources and sinks. We will present recent atmospheric methane measurements, and their correlations with a variety of environmental conditions at the location of Curiosity, and discuss the mechanisms that are believed to be contributing to the low background methane signals and their variation. 1 "Mars Methane Detection and Variability at Gale Crater", C. R. Webster et al., Science, 347, 415-417 (2015) and references therein. The research described here was carried out in part at the Jet Propulsion Laboratory, California Institute of Technology, under a contract with the National Aeronautics and Space Administration (NASA).

  10. Perceptions and attitudes toward SLMTA amongst laboratory and hospital professionals in Ethiopia.

    PubMed

    Lulie, Adino D; Hiwotu, Tilahun M; Mulugeta, Achamyeleh; Kebede, Adisu; Asrat, Habtamu; Abebe, Abnet; Yenealem, Dereje; Abose, Ebise; Kassa, Wondwossen; Kebede, Amha; Linde, Mary K; Ayana, Gonfa

    2014-01-01

    Strengthening Laboratory Management Toward Accreditation (SLMTA) is a competency-based management training programme. Assessing health professionals' views of SLMTA provides feedback to inform program planning, implementation and evaluation of SLMTA's training, communication and mentorship components. To assess laboratory professionals' and hospital chief executive officers' (CEOs) perceptions and attitudes toward the SLMTA programme in Ethiopia. A cross-sectional descriptive survey was conducted in March 2013 using a structured questionnaire to collect qualitative data from 72 laboratory professionals and hospital CEOs from 17 health facilities, representing all regions and two city administrations in Ethiopia. Focus groups were conducted with laboratory professionals and hospital administration to gain insight into the strengths and challenges of the SLMTA programme so as to guide future planning and implementation. Ethiopian laboratory professionals at all levels had a supportive attitude toward the SLMTA programme. They believed that SLMTA substantially improved laboratory services and acted as a catalyst for total healthcare reform and improvement. They also noted that the SLMTA programme achieved marked progress in laboratory supply chain, sample referral, instrument maintenance and data management systems. In contrast, nearly half of the participating hospital CEOs, especially those associated with low-scoring laboratories, were sceptical about the SLMTA programme, believing that the benefits of SLMTA were outweighed by the level of human resources and time commitment required. They also voiced concerns about the cost and sustainability of SLMTA. This study highlights the need for stronger engagement and advocacy with hospital administration and the importance of addressing concerns about the cost and sustainability of the SLMTA programme.

  11. Good laboratory practices guarantee biosafety in the Sierra Leone-China friendship biosafety laboratory.

    PubMed

    Wang, Qin; Zhou, Wei-Min; Zhang, Yong; Wang, Huan-Yu; Du, Hai-Jun; Nie, Kai; Song, Jing-Dong; Xiao, Kang; Lei, Wen-Wen; Guo, Jian-Qiang; Wei, He-Jiang; Cai, Kun; Wang, Yan-Hai; Wu, Jiang; Kamara, Gerard; Kamara, Idrissa; Wei, Qiang; Liang, Mi-Fang; Wu, Gui-Zhen; Dong, Xiao-Ping

    2016-06-23

    The outbreak of Ebola virus disease (EVD) in West Africa between 2014 and 2015 was the largest EDV epidemic since the identification of Ebola virus (EBOV) in 1976, and the countries most strongly affected were Sierra Leone, Guinea, and Liberia. The Sierra Leone-China Friendship Biological Safety Laboratory (SLE-CHN Biosafety Lab), a fixed Biosafety Level 3 laboratory in the capital city of Sierra Leone, was established by the Chinese government and has been active in EBOV detection since 11 March 2015. Complete management and program documents were created for the SLE-CHN Biosafety Lab, and it was divided into four zones (the green, yellow, brown, and red zones) based on the risk assessment. Different types of safe and appropriate personnel protection equipment (PPE) are used in different zones of the laboratory, and it fully meets the Biosafety Level 3 laboratory standards of the World Health Organization. Good preparedness, comprehensive risk assessment and operation documents, appropriate PPE, effective monitoring and intensive training, together with well-designed and reasonable laboratory sectioning are essential for guaranteeing biosafety.

  12. Low-level cadmium exposure and effects on kidney function

    PubMed Central

    Wallin, Maria; Sallsten, Gerd; Lundh, Thomas; Barregard, Lars

    2014-01-01

    Objectives The nephrotoxicity of cadmium at low levels of exposure, measured by urinary cadmium, has recently been questioned since co-excretion of cadmium and proteins may have causes other than cadmium toxicity. The aim of this study was to explore the relation between kidney function and low or moderate cadmium levels, measured directly in kidney biopsies. Methods We analysed cadmium in kidney biopsies (K-Cd), blood (B-Cd) and urine (U-Cd) from 109 living kidney donors in a cross-sectional study. We measured glomerular filtration rate (GFR), cystatin C in serum, albumin, β-2-microglobulin (B2M), retinol-binding protein (RBP), α-1-microglobulin (A1M), N-acetyl-β-d-glucosaminidase and kidney injury molecule 1 (KIM-1) in 24 h and overnight urine. Results We found significant positive associations between A1M excretion and K-Cd in multiple regression models including age, sex, weight, smoking and urinary flow rate. This association was also present in never-smokers. A1M was also positively associated with B-Cd and U-Cd. GFR and the other biomarkers of kidney function were not associated with K-Cd. GFR estimated from serum cystatin C showed a very poor correlation with measured GFR. KIM-1, RBP and possibly albumin were positively associated with U-Cd, but only in overnight urine. No associations were found with B2M. Conclusions Our results suggest that A1M in urine is a sensitive biomarker for effects of low-level cadmium exposure. A few associations between other renal biomarkers and U-Cd, but not K-Cd, were probably caused by physiological co-excretion or chance. PMID:25286916

  13. Factors influencing biosafety level and LAI among the staff of medical laboratories.

    PubMed

    Kozajda, Anna; Bródka, Karolina; Szadkowska-Stańczyk, Irena

    2013-01-01

    The aim of the study was to assess the biological risks of medical laboratory employees with particular focus on laboratory acquired infection (LAI), activities having the greatest risk, accidents with biological material, post exposure procedure, preventive measures and workers' knowledge about biological exposure. The study involved 9 laboratories. A questionnaire survey was attended by 123 employees and 9 heads of these units with the use of two questionnaires for laboratory workers and the managers. 32.5% of the respondents (40 persons) had an accident at least once. Needlestick or a broken glass injury covered 18.7% respondents (23 persons), while splashing the skin, mucous membranes or conjunctivae related to 22.8% (28 persons). Among the employees who had an accident, only 45% of the respondents (18 persons) reported this to the manager. Microbes dominant in the biological material were known only to 57 respondents (46.3%), less than half could correctly give an example of a disease (57 persons, 46.3%). More than half of the respondents admitted that they do not know all of the possible routes of infection while working in the laboratory (68 persons, 55.3%). In the study population, a high incidence of accidents was observed, usually during blood sampling and transfer of biological material. Condition of the workers' equipment with personal protective measures and laboratory facilities in devices to reduce the risk of infection and procedures for handling the potentially infectious material should be considered as insufficient. Lack of basic knowledge of the employees about biohazards at workplaces was shown.

  14. Radionuclide Concentrations in Soils and Vegetation at Low-Level Radioactive Waste Disposal Area G during the 1997 Growing Season

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    L. Naranjo, Jr.; P. R. Fresquez; R. J. Wechsler

    1998-08-01

    Soil and overstory and understory vegetation (washed and unwashed) collected at eight locations within and around Area G-a low-level radioactive solid-waste disposal facility at Los Alamos National Laboratory-were analyzed for 3H, 238Pu, 239Pu, 137CS, 234U, 235U, 228AC, Be, 214Bi, 60Co, 40& 54Mn, 22Na, 214Pb and 208Tl. In general, most radionuclide concentrations, with the exception of 3Ef and ~9Pu, in soils and overstory and understory vegetation collected from within and around Area G were within upper (95'%) level background concentrations. Although 3H concentrations in vegetation from most sites were significantly higher than background (>2 pCi mL-l), concentrations decreased markedly in comparisonmore » to last year's results. The highest `H concentration in vegetation was detected from a juniper tree that was growing over tritium shaft /+150; it contained 530,000 pCi 3H mL-l. Also, as in the pas~ the transuranic waste pad area contained the highest levels of 239Pu in soils and in understory vegetation as compared to other areas at Area G.« less

  15. Iron-phosphate ceramics for solidification of mixed low-level waste

    DOEpatents

    Aloy, Albert S.; Kovarskaya, Elena N.; Koltsova, Tatiana I.; Macheret, Yevgeny; Medvedev, Pavel G.; Todd, Terry

    2000-01-01

    A method of immobilizing mixed low-level waste is provided which uses low cost materials and has a relatively long hardening period. The method includes: forming a mixture of iron oxide powders having ratios, in mass %, of FeO:Fe.sub.2 O.sub.3 :Fe.sub.3 O.sub.4 equal to 25-40:40-10:35-50, or weighing a definite amount of magnetite powder. Metallurgical cinder can also be used as the source of iron oxides. A solution of the orthophosphoric acid, or a solution of the orthophosphoric acid and ferric oxide, is formed and a powder phase of low-level waste and the mixture of iron oxide powders or cinder (or magnetite powder) is also formed. The acid solution is mixed with the powder phase to form a slurry with the ratio of components (mass %) of waste:iron oxide powders or magnetite:acid solution=30-60:15-10:55-30. The slurry is blended to form a homogeneous mixture which is cured at room temperature to form the final product.

  16. Low Serum Interleukin-13 Levels Correlate with Poorer Prognoses for Colorectal Cancer Patients

    PubMed Central

    Saigusa, Susumu; Tanaka, Koji; Inoue, Yasuhiro; Toiyama, Yuji; Okugawa, Yoshinaga; Iwata, Takashi; Mohri, Yasuhiko; Kusunoki, Masato

    2014-01-01

    Interleukin-13 (IL-13) is an immunosuppressive cytokine produced by several immune cells and cancer cells. The aim of this retrospective study was to determine if serum IL-13 levels have an association with clinical outcome in patients with colorectal cancer. A total of 241 patients with colorectal cancer were enrolled in the present study. Preoperative serum IL-13 concentrations were measured by enzyme-linked immunosorbent assay. We analyzed the association of serum IL-13 levels with clinicopathological variables. Patients with lymph node metastasis, lymphatic invasion, vascular invasion, distant metastases or advanced stage of disease had significantly lower serum IL-13 levels. Low serum IL-13 was significantly associated with both poor recurrence-free and overall survival. Multivariate analysis showed that low IL-13 levels were an independent predictive marker for poor prognosis. In conclusion, our data suggest that low serum IL-13 levels may be a useful predictive marker for poor prognosis in colorectal cancer. PMID:24833143

  17. Predictors of Self-Directed Learning for Low-Qualified Employees: A Multi-Level Analysis

    ERIC Educational Resources Information Center

    Raemdonck, Isabel; van der Leeden, Rien; Valcke, Martin; Segers, Mien; Thijssen, Jo

    2012-01-01

    Purpose: This study aims to examine which variables at the level of the individual employee and at the company level are predictors of self-directed learning in low-qualified employees. Methodology: Results were obtained from a sample of 408 low-qualified employees from 35 different companies. The companies were selected from the energy sector,…

  18. Geohydrologic aspects for siting and design of low-level radioactive-waste disposal

    USGS Publications Warehouse

    Bedinger, M.S.

    1989-01-01

    The objective for siting and design of low-level radioactive-waste repository sites is to isolate the waste from the biosphere until the waste no longer poses an unacceptable hazard as a result of radioactive decay. Low-level radioactive waste commonly is isolated at shallow depths with various engineered features to stabilize the waste and to reduce its dissolution and transport by ground water. The unsaturated zone generally is preferred for isolating the waste. Low-level radioactive waste may need to be isolated for 300 to 500 years. Maintenance and monitoring of the repository site are required by Federal regulations for only the first 100 years. Therefore, geohydrology of the repository site needs to provide natural isolation of the waste for the hazardous period following maintenance of the site. Engineering design of the repository needs to be compatible with the natural geohydrologic conditions at the site. Studies at existing commercial and Federal waste-disposal sites provide information on the problems encountered and the basis for establishing siting guidelines for improved isolation of radioactive waste, engineering design of repository structures, and surveillance needs to assess the effectiveness of the repositories and to provide early warning of problems that may require remedial action.Climate directly affects the hydrology of a site and probably is the most important single factor that affects the suitability of a site for shallow-land burial of low-level radioactive waste. Humid and subhumid regions are not well suited for shallow isolation of low-level radioactive waste in the unsaturated zone; arid regions with zero to small infiltration from precipitation, great depths to the water table, and long flow paths to natural discharge areas are naturally well suited to isolation of the waste. The unsaturated zone is preferred for isolation of low-level radioactive waste. The guiding rationale is to minimize contact of water with the waste and to

  19. Low-lying level structure of 56Cu and its implications for the rp process

    NASA Astrophysics Data System (ADS)

    Ong, W.-J.; Langer, C.; Montes, F.; Aprahamian, A.; Bardayan, D. W.; Bazin, D.; Brown, B. A.; Browne, J.; Crawford, H.; Cyburt, R.; Deleeuw, E. B.; Domingo-Pardo, C.; Gade, A.; George, S.; Hosmer, P.; Keek, L.; Kontos, A.; Lee, I.-Y.; Lemasson, A.; Lunderberg, E.; Maeda, Y.; Matos, M.; Meisel, Z.; Noji, S.; Nunes, F. M.; Nystrom, A.; Perdikakis, G.; Pereira, J.; Quinn, S. J.; Recchia, F.; Schatz, H.; Scott, M.; Siegl, K.; Simon, A.; Smith, M.; Spyrou, A.; Stevens, J.; Stroberg, S. R.; Weisshaar, D.; Wheeler, J.; Wimmer, K.; Zegers, R. G. T.

    2017-05-01

    The low-lying energy levels of proton-rich 56Cu have been extracted using in-beam γ -ray spectroscopy with the state-of-the-art γ -ray tracking array GRETINA in conjunction with the S800 spectrograph at the National Superconducting Cyclotron Laboratory at Michigan State University. Excited states in 56Cu serve as resonances in the 55Ni(p ,γ )56Cu reaction, which is a part of the rp process in type-I x-ray bursts. To resolve existing ambiguities in the reaction Q value, a more localized isobaric multiplet mass equation (IMME) fit is used, resulting in Q =639 ±82 keV. We derive the first experimentally constrained thermonuclear reaction rate for 55Ni(p ,γ )56Cu . We find that, with this new rate, the rp process may bypass the 56Ni waiting point via the 55Ni(p ,γ ) reaction for typical x-ray burst conditions with a branching of up to ˜40 % . We also identify additional nuclear physics uncertainties that need to be addressed before drawing final conclusions about the rp -process reaction flow in the 56Ni region.

  20. 41 CFR 109-42.1102-52 - Low level contaminated personal property.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 42.11-Special Types of Hazardous Material and Certain Categories of Property § 109-42.1102-52 Low... 41 Public Contracts and Property Management 3 2012-01-01 2012-01-01 false Low level contaminated personal property. 109-42.1102-52 Section 109-42.1102-52 Public Contracts and Property Management Federal...

  1. A Baroclinic Nocturnal Low-Level Jet over the Great Plains

    NASA Astrophysics Data System (ADS)

    Shapiro, A.; Gebauer, J.; Fedorovich, E.

    2016-12-01

    The nocturnal low-level jet (LLJ) is a warm-season atmospheric boundary layer phenomenon common to the Great Plains of the United States and other places worldwide. Low-level jets develop around sunset in fair weather conditions conducive to strong radiative cooling and reach peak intensity in the pre-dawn hours. Key precursors to their formation are the establishment of a strongly turbulent dry convective boundary layer during the afternoon and a rapid cessation of the turbulence during the early evening transition. The two main physical mechanisms underpinning the generation of nocturnal low-level jets over the Great Plains are associated with diurnal variations in turbulent mixing (Blackadar mechanism) and in heating/cooling of the gently sloping terrain (Holton mechanism). These two mechanisms were recently combined within a single unified theory (Shapiro et al. 2016) in which analytical solutions of the Boussinesq equations of motion and thermal energy were obtained. In the present study we apply the unified theory to the case where the free-atmosphere geostrophic wind is zero, and there is strong daytime heating of the slope. When appropriately tuned, the analytical model predicts the low elevation (jet nose within 250 m of the ground) and strong wind maximum (> 15 m/s) characteristic of the strongly baroclinic jet observed over northern Kansas on 10 June 2015 during Intensive Observing Period 7 of the Plains Elevated Convection at Night (PECAN) field experiment. Although there is generally good agreement between the tuned model and observations (including soundings and aircraft data), our main interest is in investigating the profound roles of the free-atmosphere stratification, daytime heating, and daytime/nighttime mixing on jet strength and structure.

  2. ATWS analysis for Browns Ferry Nuclear Plant Unit 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dallman, R.J.; Jouse, W.C.

    1985-01-01

    Analyses of postulated Anticipated Transients Without Scram (ATWS) were performed at the Idaho National Engineering Laboratory (INEL). The Browns Ferry Nuclear Plant Unit 1 (BFNP1) was selected as the subject of this work because of the cooperation of the Tennessee Valley Authority (TVA). The work is part of the Severe Accident Sequence Analysis (SASA) Program of the US Nuclear Regulatory Commission (NRC). A Main Steamline Isolation Valve (MSIV) closure served as the transient initiator for these analyses, which proceeded a complete failure to scram. Results from the analyses indicate that operator mitigative actions are required to prevent overpressurization of themore » primary containment. Uncertainties remain concerning the effectiveness of key mitigative actions. The effectiveness of level control as a power reduction procedure is limited. Power level resulting from level control only reduce the Pressure Suppression Pool (PSP) heatup rate from 6 to 4F/min.« less

  3. Single Photon Counting Detectors for Low Light Level Imaging Applications

    NASA Astrophysics Data System (ADS)

    Kolb, Kimberly

    2015-10-01

    This dissertation presents the current state-of-the-art of semiconductor-based photon counting detector technologies. HgCdTe linear-mode avalanche photodiodes (LM-APDs), silicon Geiger-mode avalanche photodiodes (GM-APDs), and electron-multiplying CCDs (EMCCDs) are compared via their present and future performance in various astronomy applications. LM-APDs are studied in theory, based on work done at the University of Hawaii. EMCCDs are studied in theory and experimentally, with a device at NASA's Jet Propulsion Lab. The emphasis of the research is on GM-APD imaging arrays, developed at MIT Lincoln Laboratory and tested at the RIT Center for Detectors. The GM-APD research includes a theoretical analysis of SNR and various performance metrics, including dark count rate, afterpulsing, photon detection efficiency, and intrapixel sensitivity. The effects of radiation damage on the GM-APD were also characterized by introducing a cumulative dose of 50 krad(Si) via 60 MeV protons. Extensive development of Monte Carlo simulations and practical observation simulations was completed, including simulated astronomical imaging and adaptive optics wavefront sensing. Based on theoretical models and experimental testing, both the current state-of-the-art performance and projected future performance of each detector are compared for various applications. LM-APD performance is currently not competitive with other photon counting technologies, and are left out of the application-based comparisons. In the current state-of-the-art, EMCCDs in photon counting mode out-perform GM-APDs for long exposure scenarios, though GM-APDs are better for short exposure scenarios (fast readout) due to clock-induced-charge (CIC) in EMCCDs. In the long term, small improvements in GM-APD dark current will make them superior in both long and short exposure scenarios for extremely low flux. The efficiency of GM-APDs will likely always be less than EMCCDs, however, which is particularly disadvantageous for

  4. Detection of low-level environmental chemical allergy by a long-term sensitization method.

    PubMed

    Fukuyama, Tomoki; Ueda, Hideo; Hayashi, Koichi; Tajima, Yukari; Shuto, Yasufumi; Saito, Toru R; Harada, Takanori; Kosaka, Tadashi

    2008-07-30

    Multiple chemical sensitivity (MCS) is characterized by various signs, including neurological disorders and allergy. Exposure may occur through a major event, such as a chemical spill, or from long-term contact with chemicals at low levels. We are interested in the allergenicity of MCS and the detection of low-level chemical-related hypersensitivity. We used long-term sensitization followed by low-dose challenge to evaluate sensitization by well-known Th2 type sensitizers (trimellitic anhydride (TMA) and toluene diisocyanate (TDI)) and a Th1 type sensitizer (2,4-dinitrochlorobenzene (DNCB)). After topically sensitizing BALB/c mice (9 times in 3 weeks) and challenging them with TMA, TDI or DNCB, we assayed their auricular lymph nodes (LNs) for number of lymphocytes, surface antigen expression of B cells, and local cytokine production, and measured antigen-specific serum IgE levels. TMA and TDI induced marked increases in levels of antigen-specific serum IgE and of Th2 cytokines (IL-4, IL-5, IL-10, and IL-13) produced by ex vivo restimulated lymph node cells. DNCB induced a marked increase in Th1 cytokine (IL-2, IFN-gamma, and TNF-alpha) levels, but antigen-specific serum IgE levels were not elevated. All chemicals induced significant increases in number of lymphocytes and surface antigen expression of B cells. Our mouse model enabled the identification and characterization of chemical-related allergic reactions at low levels. This long-term sensitization method would be useful for detecting environmental chemical-related hypersensitivity.

  5. Silica exposure to excavation workers during the excavation of a low level radiological waste pit and tritium disposal shafts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, K.M.

    1995-01-01

    This study evaluated the task-length average (TLA) respirable dust and respirable silica airborne concentrations to which construction workers excavating volcanic tuff at Los Alamos National Laboratory (LANL) were exposed. These workers were excavating a low level radiological waste disposal pit of final dimensions 720 feet long, 132 feet wide and 60 feet deep. The objectives of this study were as follows: (1) evaluate exposures; (2) determine if the type of machinery used affects the respirable dust concentration in the breathing zone of the worker; (3) evaluate the efficacy of wetting the pit to reduce the respirable dust exposure; and (4)more » determine if exposure increases with increasing depth of pit due to the walls of the pit blocking the cross wind ventilation.« less

  6. [Current problems arising from not having biosafety level 4 laboratories in Japan--qualitative study of infectious disease experts].

    PubMed

    Yamamoto, Yuko; Horiguchi, Itsuko; Marui, Eiji

    2009-09-01

    No public consensus exists yet on handling Biosafety Level 4 agents and no laboratory is operational at BSL4 in Japan. A discussion that includes neighboring residents and experts should be initiated to communicate risks. In this article, we present the current situation and prioritize problems we presently face. A three-stage Delphi survey was conducted. The subjects were twenty-two persons with extensive experience and knowledge of infectious diseases. Seven projections and issues were made with regard to the problems arising from the lack of an operational BSL4 laboratory. These were tabulated by the KJ method. The top seven projections were scored, such that the top received 7 points and the last received 1 point. A total of 51 projections were obtained for the first part of the survey, 39 for the second, and 29 for the last. The projection with the highest score was that it is impossible to cope with newly emerging infectious diseases. The second was that complete diagnoses are impossible without a BSL4 laboratory. All projections and issues were divided into the following four main groups: issues for researchers and laboratory staff, clinical practice and research on BSL4 agents, domestic and global security, and Japan's international position. We clarified possible problem arising from not having BSL4 laboratories in Japan. The identification of projections by the Delphi survey in this study should be considered as one of many attempts to develop effective risk communication strategies.

  7. Genome-wide association studies identify genetic loci for low von Willebrand factor levels

    PubMed Central

    van Loon, Janine; Dehghan, Abbas; Weihong, Tang; Trompet, Stella; McArdle, Wendy L; Asselbergs, Folkert F W; Chen, Ming-Huei; Lopez, Lorna M; Huffman, Jennifer E; Leebeek, Frank W G; Basu, Saonli; Stott, David J; Rumley, Ann; Gansevoort, Ron T; Davies, Gail; Wilson, James J F; Witteman, Jacqueline C M; Cao, Xiting; de Craen, Anton J M; Bakker, Stephan J L; Psaty, Bruce M; Starr, John M; Hofman, Albert; Wouter Jukema, J; Deary, Ian J; Hayward, Caroline; van der Harst, Pim; Lowe, Gordon D O; Folsom, Aaron R; Strachan, David P; Smith, Nicolas; de Maat, Moniek P M; O'Donnell, Christopher

    2016-01-01

    Low von Willebrand factor (VWF) levels are associated with bleeding symptoms and are a diagnostic criterion for von Willebrand disease, the most common inherited bleeding disorder. To date, it is unclear which genetic loci are associated with reduced VWF levels. Therefore, we conducted a meta-analysis of genome-wide association studies to identify genetic loci associated with low VWF levels. For this meta-analysis, we included 31 149 participants of European ancestry from 11 community-based studies. From all participants, VWF antigen (VWF:Ag) measurements and genome-wide single-nucleotide polymorphism (SNP) scans were available. Each study conducted analyses using logistic regression of SNPs on dichotomized VWF:Ag measures (lowest 5% for blood group O and non-O) with an additive genetic model adjusted for age and sex. An inverse-variance weighted meta-analysis was performed for VWF:Ag levels. A total of 97 SNPs exceeded the genome-wide significance threshold of 5 × 10−8 and comprised five loci on four different chromosomes: 6q24 (smallest P-value 5.8 × 10−10), 9q34 (2.4 × 10−64), 12p13 (5.3 × 10−22), 12q23 (1.2 × 10−8) and 13q13 (2.6 × 10−8). All loci were within or close to genes, including STXBP5 (Syntaxin Binding Protein 5) (6q24), STAB5 (stabilin-5) (12q23), ABO (9q34), VWF (12p13) and UFM1 (ubiquitin-fold modifier 1) (13q13). Of these, UFM1 has not been previously associated with VWF:Ag levels. Four genes that were previously associated with VWF levels (VWF, ABO, STXBP5 and STAB2) were also associated with low VWF levels, and, in addition, we identified a new gene, UFM1, that is associated with low VWF levels. These findings point to novel mechanisms for the occurrence of low VWF levels. PMID:26486471

  8. A Simple and Low-Cost Monitoring System to Investigate Environmental Conditions in a Biological Research Laboratory

    PubMed Central

    Gurdita, Akshay; Vovko, Heather; Ungrin, Mark

    2016-01-01

    Basic equipment such as incubation and refrigeration systems plays a critical role in nearly all aspects of the traditional biological research laboratory. Their proper functioning is therefore essential to ensure reliable and repeatable experimental results. Despite this fact, in many academic laboratories little attention is paid to validating and monitoring their function, primarily due to the cost and/or technical complexity of available commercial solutions. We have therefore developed a simple and low-cost monitoring system that combines a “Raspberry Pi” single-board computer with USB-connected sensor interfaces to track and log parameters such as temperature and pressure, and send email alert messages as appropriate. The system is controlled by open-source software, and we have also generated scripts to automate software setup so that no background in programming is required to install and use it. We have applied it to investigate the behaviour of our own equipment, and present here the results along with the details of the monitoring system used to obtain them. PMID:26771659

  9. Inter-laboratory consistency and variability in the buccal micronucleus cytome assay depends on biomarker scored and laboratory experience: results from the HUMNxl international inter-laboratory scoring exercise.

    PubMed

    Bolognesi, Claudia; Knasmueller, Siegfried; Nersesyan, Armen; Roggieri, Paola; Ceppi, Marcello; Bruzzone, Marco; Blaszczyk, Ewa; Mielzynska-Svach, Danuta; Milic, Mirta; Bonassi, Stefano; Benedetti, Danieli; Da Silva, Juliana; Toledo, Raphael; Salvadori, Daisy Maria Fávero; Groot de Restrepo, Helena; Filipic, Metka; Hercog, Klara; Aktas, Ayça; Burgaz, Sema; Kundi, Michael; Grummt, Tamara; Thomas, Philip; Hor, Maryam; Escudero-Fung, Maria; Holland, Nina; Fenech, Michael

    2017-03-01

    The buccal micronucleus cytome (BMNcyt) assay in uncultured exfoliated epithelial cells from oral mucosa is widely applied in biomonitoring human exposures to genotoxic agents and is also proposed as a suitable test for prescreening and follow-up of precancerous oral lesions. The main limitation of the assay is the large variability observed in the baseline values of micronuclei (MNi) and other nuclear anomalies mainly related to different scoring criteria. The aim of this international collaborative study, involving laboratories with different level of experience, was to evaluate the inter- and intra-laboratory variations in the BMNcyt parameters, using recently implemented guidelines, in scoring cells from the same pooled samples obtained from healthy subjects (control group) and from cancer patients undergoing radiotherapy (treated group). The results indicate that all laboratories correctly discriminated samples from the two groups by a significant increase of micronucleus (MN) and nuclear bud (NBUD) frequencies and differentiated binucleated (BN) cells, associated with the exposure to ionizing radiation. The experience of the laboratories was shown to play an important role in the identification of the different cell types and nuclear anomalies. MN frequency in differentiated mononucleated (MONO) and BN cells showed the greatest consistency among the laboratories and low variability was also detected in the frequencies of MONO and BN cells. A larger variability was observed in classifying the different cell types, indicating the subjectivity in the interpretation of some of the scoring criteria while reproducibility of the results between scoring sessions was very good. An inter-laboratory calibration exercise is strongly recommended before starting studies with BMNcyt assay involving multiple research centers. © The Author 2016. Published by Oxford University Press on behalf of the UK Environmental Mutagen Society. All rights reserved. For permissions

  10. Low-level Laser Therapy for Traumatic Brain Injury

    DTIC Science & Technology

    2014-10-01

    performance and consists of a photodiode power sensor within a black plastic housing unit to confirm the output of each LED matrix in the helmet. We tested...could be significantly reversed by low level light therapy (LLLT) in vitro study. The effect of LLLT was furthered by a combination with metabolic...it will indicate both a mechanisms of action and provide a strategy for monitoring the effect of LLLT in clinical settings (for example, using

  11. Efficacy of Low Level Laser Therapy After Hand Flexor Tendon Repair

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ayad, K. E.; Abd El Mejeed, S. F.; El Gohary, H. M.

    Flexor tendon injury is a common problem requiring suturing repair followed by early postoperative mobilization. Muscle atrophy, joint stiffness, osteoarthritis, infection, skin necrosis, ulceration of joint cartilage and tendocutaneous adhesion are familiar complications produced by prolonged immobilization of surgically repaired tendon ruptures. The purpose of this study was to clarify the importance of low level laser therapy after hand flexor tendon repair in zone II. Thirty patients aging between 20 and 40 years were divided into two groups. Patients in group A (n = 15) received a conventional therapeutic exercise program while patients in group B (n = 15) receivedmore » low level laser therapy combined with the same therapeutic exercise program. The results showed a statistically significant increase in total active motion of the proximal and distal interphalangeal joints as well as maximum hand grip strength at three weeks and three months postoperative, but improvement was more significant in group B. It was concluded that the combination of low level laser therapy and early therapeutic exercises was more effective than therapeutic exercises alone in improving total active motion of proximal and distal interphalangeal joints and hand grip strength after hand flexor tendon repair.« less

  12. Testosterone treatment and the risk of aggressive prostate cancer in men with low testosterone levels.

    PubMed

    Walsh, Thomas J; Shores, Molly M; Krakauer, Chloe A; Forsberg, Christopher W; Fox, Alexandra E; Moore, Kathryn P; Korpak, Anna; Heckbert, Susan R; Zeliadt, Steven B; Kinsey, Chloe E; Thompson, Mary Lou; Smith, Nicholas L; Matsumoto, Alvin M

    2018-01-01

    Testosterone treatment of men with low testosterone is common and, although relatively short-term, has raised concern regarding an increased risk of prostate cancer (CaP). We investigated the association between modest-duration testosterone treatment and incident aggressive CaP. Retrospective inception cohort study of male Veterans aged 40 to 89 years with a laboratory-defined low testosterone measurement from 2002 to 2011 and recent prostate specific antigen (PSA) testing; excluding those with recent testosterone treatment, prostate or breast cancer, high PSA or prior prostate biopsy. Histologically-confirmed incident aggressive prostate cancer or any prostate cancer were the primary and secondary outcomes, respectively. Of the 147,593 men included, 58,617 were treated with testosterone. 313 aggressive CaPs were diagnosed, 190 among untreated men (incidence rate (IR) 0.57 per 1000 person years, 95% CI 0.49-0.65) and 123 among treated men (IR 0.58 per 1000 person years; 95% CI 0.48-0.69). After adjusting for age, race, hospitalization during year prior to cohort entry, geography, BMI, medical comorbidities, repeated testosterone and PSA testing, testosterone treatment was not associated with incident aggressive CaP (HR 0.89; 95% CI 0.70-1.13) or any CaP (HR 0.90; 95% CI 0.81-1.01). No association between cumulative testosterone dose or formulation and CaP was observed. Among men with low testosterone levels and normal PSA, testosterone treatment was not associated with an increased risk of aggressive or any CaP. The clinical risks and benefits of testosterone treatment can only be fully addressed by large, longer-term randomized controlled trials.

  13. Testosterone Treatment and Sexual Function in Older Men With Low Testosterone Levels.

    PubMed

    Cunningham, Glenn R; Stephens-Shields, Alisa J; Rosen, Raymond C; Wang, Christina; Bhasin, Shalender; Matsumoto, Alvin M; Parsons, J Kellogg; Gill, Thomas M; Molitch, Mark E; Farrar, John T; Cella, David; Barrett-Connor, Elizabeth; Cauley, Jane A; Cifelli, Denise; Crandall, Jill P; Ensrud, Kristine E; Gallagher, Laura; Zeldow, Bret; Lewis, Cora E; Pahor, Marco; Swerdloff, Ronald S; Hou, Xiaoling; Anton, Stephen; Basaria, Shehzad; Diem, Susan J; Tabatabaie, Vafa; Ellenberg, Susan S; Snyder, Peter J

    2016-08-01

    The Testosterone Trials are a coordinated set of seven trials to determine the efficacy of T in symptomatic men ≥65 years old with unequivocally low T levels. Initial results of the Sexual Function Trial showed that T improved sexual activity, sexual desire, and erectile function. To assess the responsiveness of specific sexual activities to T treatment; to relate hormone changes to changes in sexual function; and to determine predictive baseline characteristics and T threshold for sexual outcomes. A placebo-controlled trial. Twelve academic medical centers in the United States. A total of 470 men ≥65 years of age with low libido, average T <275 ng/dL, and a partner willing to have sexual intercourse at least twice a month. Men were assigned to take T gel or placebo for 1 year. Sexual function was assessed by three questionnaires every 3 months: the Psychosexual Daily Questionnaire, the Derogatis Interview for Sexual Function, and the International Index of Erectile Function. Compared with placebo, T administration significantly improved 10 of 12 measures of sexual activity. Incremental increases in total and free T and estradiol levels were associated with improvements in sexual activity and desire, but not erectile function. No threshold T level was observed for any outcome, and none of the 27 baseline characteristics predicted responsiveness to T. In older men with low libido and low T levels, improvements in sexual desire and activity in response to T treatment were related to the magnitude of increases in T and estradiol levels, but there was no clear evidence of a threshold effect.

  14. Neural Tuning to Low-Level Features of Speech throughout the Perisylvian Cortex.

    PubMed

    Berezutskaya, Julia; Freudenburg, Zachary V; Güçlü, Umut; van Gerven, Marcel A J; Ramsey, Nick F

    2017-08-16

    Despite a large body of research, we continue to lack a detailed account of how auditory processing of continuous speech unfolds in the human brain. Previous research showed the propagation of low-level acoustic features of speech from posterior superior temporal gyrus toward anterior superior temporal gyrus in the human brain (Hullett et al., 2016). In this study, we investigate what happens to these neural representations past the superior temporal gyrus and how they engage higher-level language processing areas such as inferior frontal gyrus. We used low-level sound features to model neural responses to speech outside of the primary auditory cortex. Two complementary imaging techniques were used with human participants (both males and females): electrocorticography (ECoG) and fMRI. Both imaging techniques showed tuning of the perisylvian cortex to low-level speech features. With ECoG, we found evidence of propagation of the temporal features of speech sounds along the ventral pathway of language processing in the brain toward inferior frontal gyrus. Increasingly coarse temporal features of speech spreading from posterior superior temporal cortex toward inferior frontal gyrus were associated with linguistic features such as voice onset time, duration of the formant transitions, and phoneme, syllable, and word boundaries. The present findings provide the groundwork for a comprehensive bottom-up account of speech comprehension in the human brain. SIGNIFICANCE STATEMENT We know that, during natural speech comprehension, a broad network of perisylvian cortical regions is involved in sound and language processing. Here, we investigated the tuning to low-level sound features within these regions using neural responses to a short feature film. We also looked at whether the tuning organization along these brain regions showed any parallel to the hierarchy of language structures in continuous speech. Our results show that low-level speech features propagate throughout the

  15. Low zinc serum levels and high blood lead levels among school-age children in coastal area

    NASA Astrophysics Data System (ADS)

    Pramono, Adriyan; Panunggal, Binar; Rahfiludin, M. Zen; Swastawati, Fronthea

    2017-02-01

    The coverage of environmental lead toxicant was quiet wide. Lead exposure recently has been expected to be associated with zinc deficiency and blood indices disturbance. Emphasizing on children, which could absorb more than 50 % of lead that enters the body. Lead became the issue on the coastal area due to it has polluted the environment and waters as the source of fisheries products. This was a cross sectional study to determined nutritional status, blood lead levels, zinc serum levels, blood indices levels, fish intake among school children in coastal region of Semarang. This study was carried out on the school children aged between 8 and 12 years old in coastal region of Semarang. Nutritional status was figured out using anthropometry measurement. Blood lead and zinc serum levels were analyzed using the Atomic Absorbent Spectrophotometry (AAS) at a wavelength of 213.9 nm for zinc serum and 283.3 nm for blood lead. Blood indices was measured using auto blood hematology analyzer. Fish intake was assessed using 3-non consecutive days 24-hours food recall. The children had high lead levels (median 34.86 μg/dl, range 11.46 - 58.86 μg/dl) compared to WHO cut off. Zinc serum levels was low (median 18.10 μg/dl, range 10.25 - 41.39 μg/dl) compared to the Joint WHO/UNICEF/IAEA/IZiNCG cut off. Approximately 26.4% of children were anemic. This study concluded that all school children had high blood lead levels, low zinc serum, and presented microcytic hypochromic anemia. This phenomenon should be considered as public health concern.

  16. Moscow Test Well, INEL Oversight Program: Aqueous geochemistry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCurry, M.; Fromm, J.; Welhan, J.

    1992-09-29

    This report presents a summary and interpretation of data gathered during sampling of the Moscow Test Well at Moscow, Idaho during April and May of 1992. The principal objectives of this chemical survey were to validate sampling procedures with a new straddle packer sampling tool in a previously hydrologically well characterized and simple sampling environment, and to compare analytical results from two independent labs for reproducibility of analytical results. Analytes included a wide range of metals, anions, nutrients, BNA`s, and VOC`s. Secondary objectives included analyzing of waters from a large distilled water tank (utilized for all field laboratory purposes asmore » ``pure`` stock water), of water which passed through a steamer used to clean the packer, and of rinsates from the packer tool itself before it was lowered into the test well. Analyses were also obtained of blanks and spikes for data validation purposes.« less

  17. 76 FR 58543 - Draft Policy Statement on Volume Reduction and Low-Level Radioactive Waste Management

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-21

    ...-Level Radioactive Waste Management AGENCY: Nuclear Regulatory Commission. ACTION: Reopening of comment... for public comment a draft Policy Statement on Volume Reduction and Low-Level Radioactive Waste Management that updates the 1981 Policy Statement on Low-Level Waste Volume Reduction. The revised Policy...

  18. Low pH Springs - A Natural Laboratory for Ocean Acidification

    NASA Astrophysics Data System (ADS)

    Derse, E.; Rebolledo-Vieyra, M.; Potts, D. C.; Paytan, A.

    2009-12-01

    Recent increases in atmospheric carbon dioxide of 40% above pre-industrial levels has resulted in rising aqueous CO2 concentrations that lower the pH of the oceans. Currently, the surface ocean has an average pH between 8.1 and 8.2: it is estimated that over the next 100 years this value will decrease by ~0.4 pH units. Previous studies have highlighted the negative impacts that changes in pH (and the resulting CaCO3 saturation state) have on marine organisms; however, to date, very little is known about the long-term impacts of ocean acidification on ecosystems as a whole. The Yucatán Peninsula of Quintana Roo, Mexico, represents an ecosystem where naturally low pH groundwater (7.25-8.07) has been discharging offshore at highly localized points (called ojos) since the last deglaciation. We present preliminary chemical and biological data on a selection of ojos from lagoon sites in Puerto Morelos, Mexico. We address the potential long-term implications of low pH waters on marine ecosystems.

  19. Low-level light treatment ameliorates immune thrombocytopenia

    NASA Astrophysics Data System (ADS)

    Yang, Jingke; Zhang, Qi; Wu, Mei X.

    2017-02-01

    Immune thrombocytopenia (ITP) is an immune-mediated acquired bleeding disorder characterized by abnormally low platelet counts. We reported here the ability of low-level light treatment (LLLT) to alleviate ITP in mice. The treatment is based on noninvasive whole body illumination 30 min a day for a few consecutive days by near infrared light (830 nm) transmitted by an array of light-emitting diodes (LEDs). LLLT significantly lifted the nadir of platelet counts and restored tail bleeding time when applied to two passive ITP models induced by anti-CD41 antibody. The anti-platelet antibody hindered megakaryocyte differentiation from the progenitors, impaired proplatelet and platelet formation, and induced apoptosis of platelets. These adverse effects of anti-CD41 antibody were all mitigated by LLLT to varying degrees, owing to its ability to enhance mitochondrial biogenesis and activity in megakaryocytes and preserve mitochondrial functions in platelets in the presence of the antibody. The observations argue not only for contribution of mitochondrial stress to the pathology of ITP, but also clinical potentials of LLLT as a safe, simple, and cost-effective modality of ITP.

  20. The development of a highly constrained health level 7 implementation guide to facilitate electronic laboratory reporting to ambulatory electronic health record systems.

    PubMed

    Sujansky, Walter V; Overhage, J Marc; Chang, Sophia; Frohlich, Jonah; Faus, Samuel A

    2009-01-01

    Electronic laboratory interfaces can significantly increase the value of ambulatory electronic health record (EHR) systems by providing laboratory result data automatically and in a computable form. However, many ambulatory EHRs cannot implement electronic laboratory interfaces despite the existence of messaging standards, such as Health Level 7, version 2 (HL7). Among several barriers to implementing laboratory interfaces is the extensive optionality within the HL7 message standard. This paper describes the rationale for and development of an HL7 implementation guide that seeks to eliminate most of the optionality inherent in HL7, but retain the information content required for reporting outpatient laboratory results. A work group of heterogeneous stakeholders developed the implementation guide based on a set of design principles that emphasized parsimony, practical requirements, and near-term adoption. The resulting implementation guide contains 93% fewer optional data elements than HL7. This guide was successfully implemented by 15 organizations during an initial testing phase and has been approved by the HL7 standards body as an implementation guide for outpatient laboratory reporting. Further testing is required to determine whether widespread adoption of the implementation guide by laboratories and EHR systems can facilitate the implementation of electronic laboratory interfaces.