Sample records for laboratory netl vision

  1. NETL - Thermogravimetric Analysis Laboratory

    ScienceCinema

    Richards, George

    2018-06-22

    Researchers in NETL's Thermal Analysis Laboratory are investigating chemical looping combustion. As a clean and efficient fossil fuel technology, chemical looping combustion controls CO2 emissions and offers a promising alternative to traditional combustion.

  2. NETL Extreme Drilling Laboratory Studies High Pressure High Temperature Drilling Phenomena

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lyons, K.D.; Honeygan, S.; Moroz, T.H.

    2008-12-01

    The U.S. Department of Energy's National Energy Technology Laboratory (NETL) established the Extreme Drilling Laboratory to engineer effective and efficient drilling technologies viable at depths greater than 20,000 ft. This paper details the challenges of ultradeep drilling, documents reports of decreased drilling rates as a result of increasing fluid pressure and temperature, and describes NETL's research and development activities. NETL is invested in laboratory-scale physical simulation. Its physical simulator will have capability of circulating drilling fluids at 30,000 psi and 480°F around a single drill cutter. This simulator is not yet operational; therefore, the results will be limited to themore » identification of leading hypotheses of drilling phenomena and NETL's test plans to validate or refute such theories. Of particular interest to the Extreme Drilling Laboratory's studies are the combinatorial effects of drilling fluid pressure, drilling fluid properties, rock properties, pore pressure, and drilling parameters, such as cutter rotational speed, weight on bit, and hydraulics associated with drilling fluid introduction to the rock-cutter interface. A detailed discussion of how each variable is controlled in a laboratory setting will be part of the conference paper and presentation.« less

  3. NETL Extreme Drilling Laboratory Studies High Pressure High Temperature Drilling Phenomena

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lyons, K.D.; Honeygan, S.; Moroz, T

    2007-06-01

    The U.S. Department of Energy’s National Energy Technology Laboratory (NETL) established an Extreme Drilling Lab to engineer effective and efficient drilling technologies viable at depths greater than 20,000 feet. This paper details the challenges of ultra-deep drilling, documents reports of decreased drilling rates as a result of increasing fluid pressure and temperature, and describes NETL’s Research and Development activities. NETL is invested in laboratory-scale physical simulation. Their physical simulator will have capability of circulating drilling fluids at 30,000 psi and 480 °F around a single drill cutter. This simulator will not yet be operational by the planned conference dates; therefore,more » the results will be limited to identification of leading hypotheses of drilling phenomena and NETL’s test plans to validate or refute such theories. Of particular interest to the Extreme Drilling Lab’s studies are the combinatorial effects of drilling fluid pressure, drilling fluid properties, rock properties, pore pressure, and drilling parameters, such as cutter rotational speed, weight on bit, and hydraulics associated with drilling fluid introduction to the rock-cutter interface. A detailed discussion of how each variable is controlled in a laboratory setting will be part of the conference paper and presentation.« less

  4. NETL CT Imaging Facility

    ScienceCinema

    None

    2018-02-13

    NETL's CT Scanner laboratory is equipped with three CT scanners and a mobile core logging unit that work together to provide characteristic geologic and geophysical information at different scales, non-destructively.

  5. NETL - Supercomputing: NETL Simulation Based Engineering User Center (SBEUC)

    ScienceCinema

    None

    2018-02-07

    NETL's Simulation-Based Engineering User Center, or SBEUC, integrates one of the world's largest high-performance computers with an advanced visualization center. The SBEUC offers a collaborative environment among researchers at NETL sites and those working through the NETL-Regional University Alliance.

  6. NETL - Supercomputing: NETL Simulation Based Engineering User Center (SBEUC)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2013-09-30

    NETL's Simulation-Based Engineering User Center, or SBEUC, integrates one of the world's largest high-performance computers with an advanced visualization center. The SBEUC offers a collaborative environment among researchers at NETL sites and those working through the NETL-Regional University Alliance.

  7. NETL's JIC in a box

    ScienceCinema

    David Anna

    2017-12-09

    The National Energy Technology Laboratory developed the idea of a portable joint information center AKA JIC in-a-box. This video discribes some of the equipment in the portable JIC as well as some of the methodology that NETL developed as a result of this portable JIC concept.

  8. NETL: The First 100 Years

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    The National Energy Technology Laboratory celebrates 100 years of innovative energy technology development. NETL has been a leader in energy technology development. This video takes a look back at the many accomplishments over the past 100 years. These advances benefit the American people, enhance our nation's energy security and protect our natural resources.

  9. NETL: The First 100 Years

    ScienceCinema

    None

    2018-01-16

    The National Energy Technology Laboratory celebrates 100 years of innovative energy technology development. NETL has been a leader in energy technology development. This video takes a look back at the many accomplishments over the past 100 years. These advances benefit the American people, enhance our nation's energy security and protect our natural resources.

  10. Breakthrough: NETL's Simulation-Based Engineering User Center (SBEUC)

    ScienceCinema

    Guenther, Chris

    2018-05-23

    The National Energy Technology Laboratory relies on supercomputers to develop many novel ideas that become tomorrow's energy solutions. Supercomputers provide a cost-effective, efficient platform for research and usher technologies into widespread use faster to bring benefits to the nation. In 2013, Secretary of Energy Dr. Ernest Moniz dedicated NETL's new supercomputer, the Simulation Based Engineering User Center, or SBEUC. The SBEUC is dedicated to fossil energy research and is a collaborative tool for all of NETL and our regional university partners.

  11. Breakthrough: NETL's Simulation-Based Engineering User Center (SBEUC)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guenther, Chris

    The National Energy Technology Laboratory relies on supercomputers to develop many novel ideas that become tomorrow's energy solutions. Supercomputers provide a cost-effective, efficient platform for research and usher technologies into widespread use faster to bring benefits to the nation. In 2013, Secretary of Energy Dr. Ernest Moniz dedicated NETL's new supercomputer, the Simulation Based Engineering User Center, or SBEUC. The SBEUC is dedicated to fossil energy research and is a collaborative tool for all of NETL and our regional university partners.

  12. NETL- High-Pressure Combustion Research Facility

    ScienceCinema

    None

    2018-02-14

    NETL's High-Pressure Combustion Facility is a unique resource within the National Laboratories system. It provides the test capabilities needed to evaluate new combustion concepts for high-pressure, high-temperature hydrogen and natural gas turbines. These concepts will be critical for the next generation of ultra clean, ultra efficient power systems.

  13. NETL's Hybrid Performance, or Hyper, facility

    ScienceCinema

    None

    2018-02-13

    NETL's Hybrid Performance, or Hyper, facility is a one-of-a-kind laboratory built to develop control strategies for the reliable operation of fuel cell/turbine hybrids and enable the simulation, design, and implementation of commercial equipment. The Hyper facility provides a unique opportunity for researchers to explore issues related to coupling fuel cell and gas turbine technologies.

  14. NETL- Severe Environment Corrosion Erosion Facility

    ScienceCinema

    None

    2018-01-16

    NETL's Severe Environment Corrosion Erosion Facility in Albany studies how new and old materials will stand up to new operating conditions. Work done in the lab supports NETL's oxy-fuel combustion oxidation work, refractory materials stability work, and the fuels program, in particular the hydrogen membrane materials stability work, to determine how best to upgrade existing power plants.

  15. NETL Research Technology

    ScienceCinema

    None

    2018-01-16

    NETL is committed to providing its researchers with the latest scientific equipment. This video highlights three technologies: the Beowulf Cluster supercomputer, the OASIS Surface Analytical and Imaging System, and the gas chromatograph-inductively coupled plasma-mass spectrometer, or GC-ICP-MS.

  16. Research Performed at NETL on the Subsurface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Deep below our feet, lies the unique and complex world of the subsurface. A world that is improving the lives of Americans and brimming with the potential to generate even greater benefits through NETL research. NETL research supports industry by improving resource extraction while also helping to make carbon storage safe and more effective.

  17. NETL - Fuel Reforming Facilities

    ScienceCinema

    None

    2018-01-26

    Research using NETL's Fuel Reforming Facilities explores catalytic issues inherent in fossil-energy related applications, including catalyst synthesis and characterization, reaction kinetics, catalyst activity and selectivity, catalyst deactivation, and stability.

  18. NETL- AVESTAR

    ScienceCinema

    None

    2018-02-13

    NETL's Advanced Virtual Energy Simulation Training and Research, or AVESTAR, Center is designed to promote operational excellence for the nation's energy systems, from smart power plants to smart grid. The AVESTAR Center brings together advanced dynamic simulation and control technologies, state-of-the-art simulation-based training facilities, and leading industry experts to focus on the optimal operation of clean energy plants in the smart grid era.

  19. NETL - Chemical Looping Reactor

    ScienceCinema

    None

    2018-02-14

    NETL's Chemical Looping Reactor unit is a high-temperature integrated CLC process with extensive instrumentation to improve computational simulations. A non-reacting test unit is also used to study solids flow at ambient temperature. The CLR unit circulates approximately 1,000 pounds per hour at temperatures around 1,800 degrees Fahrenheit.

  20. Breakthrough: NETL's Research Saving Lives with Coronary Stents

    ScienceCinema

    Turner, Paul

    2018-02-14

    NETL's Albany location is world renown for its expertise in materials research. One recent offshoot of this expertise was the assistance in developing a new material for coronary stents. This research led to the development of a stent which now has a 33% global market share and has produced over four hundred sustainable jobs in the United States.

  1. NETL's Energy Data Exchange (EDX) - a coordination, collaboration, and data resource discovery platform for energy science

    NASA Astrophysics Data System (ADS)

    Rose, K.; Rowan, C.; Rager, D.; Dehlin, M.; Baker, D. V.; McIntyre, D.

    2015-12-01

    Multi-organizational research teams working jointly on projects often encounter problems with discovery, access to relevant existing resources, and data sharing due to large file sizes, inappropriate file formats, or other inefficient options that make collaboration difficult. The Energy Data eXchange (EDX) from Department of Energy's (DOE) National Energy Technology Laboratory (NETL) is an evolving online research environment designed to overcome these challenges in support of DOE's fossil energy goals while offering improved access to data driven products of fossil energy R&D such as datasets, tools, and web applications. In 2011, development of NETL's Energy Data eXchange (EDX) was initiated and offers i) a means for better preserving of NETL's research and development products for future access and re-use, ii) efficient, discoverable access to authoritative, relevant, external resources, and iii) an improved approach and tools to support secure, private collaboration and coordination between multi-organizational teams to meet DOE mission and goals. EDX presently supports fossil energy and SubTER Crosscut research activities, with an ever-growing user base. EDX is built on a heavily customized instance of the open source platform, Comprehensive Knowledge Archive Network (CKAN). EDX connects users to externally relevant data and tools through connecting to external data repositories built on different platforms and other CKAN platforms (e.g. Data.gov). EDX does not download and repost data or tools that already have an online presence. This leads to redundancy and even error. If a relevant resource already has an online instance, is hosted by another online entity, EDX will point users to that external host either using web services, inventorying URLs and other methods. EDX offers users the ability to leverage private-secure capabilities custom built into the system. The team is presently working on version 3 of EDX which will incorporate big data analytical

  2. National Research Council Research Associateships Program with Methane Hydrates Fellowships Program/National Energy Technology Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Basques, Eric O.

    2014-03-20

    This report summarizes work carried out over the period from July 5, 2005-January 31, 2014. The work was carried out by the National Research Council Research Associateships Program of the National Academies, under the US Department of Energy's National Energy Technology Laboratory (NETL) program. This Technical Report consists of a description of activity from 2005 through 2014, broken out within yearly timeframes, for NRC/NETL Associateships researchers at NETL laboratories which includes individual tenure reports from Associates over this time period. The report also includes individual tenure reports from associates over this time period. The report also includes descriptions of programmore » promotion efforts, a breakdown of the review competitions, awards offered, and Associate's activities during their tenure.« less

  3. NETL: The Science of the Very Fast and the Very Small

    ScienceCinema

    None

    2018-05-11

    From innovations in nanotechnology to discoveries that increase our understanding of energy resources around us, NETL and the National Labs are leading the way in studying the science of the very fast and very small. In fields ranging from medicine to materials, our researchers are making advancements that have practical applications in everyday life.

  4. Vision in laboratory rodents-Tools to measure it and implications for behavioral research.

    PubMed

    Leinonen, Henri; Tanila, Heikki

    2017-07-29

    Mice and rats are nocturnal mammals and their vision is specialized for detection of motion and contrast in dim light conditions. These species possess a large proportion of UV-sensitive cones in their retinas and the majority of their optic nerve axons target superior colliculus rather than visual cortex. Therefore, it was a widely held belief that laboratory rodents hardly utilize vision during day-time behavior. This dogma is being questioned as accumulating evidence suggests that laboratory rodents are able to perform complex visual functions, such as perceiving subjective contours, and that declined vision may affect their performance in many behavioral tasks. For instance, genetic engineering may have unexpected consequences on vision as mouse models of Alzheimer's and Huntington's diseases have declined visual function. Rodent vision can be tested in numerous ways using operant training or reflex-based behavioral tasks, or alternatively using electrophysiological recordings. In this article, we will first provide a summary of visual system and explain its characteristics unique to rodents. Then, we present well-established techniques to test rodent vision, with an emphasis on pattern vision: visual water test, optomotor reflex test, pattern electroretinography and pattern visual evoked potentials. Finally, we highlight the importance of visual phenotyping in rodents. As the number of genetically engineered rodent models and volume of behavioral testing increase simultaneously, the possibility of visual dysfunctions needs to be addressed. Neglect in this matter potentially leads to crude biases in the field of neuroscience and beyond. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Technical Report on NETL's Non Newtonian Multiphase Slurry Workshop: A path forward to understanding non-Newtonian multiphase slurry flows

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guenther, Chris; Garg, Rahul

    2013-08-19

    The Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) sponsored a workshop on non-Newtonian multiphase slurry at NETL’s Morgantown campus August 19 and 20, 2013. The objective of this special two-day meeting of 20-30 invited experts from industry, National Labs and academia was to identify and address technical issues associated with handling non-Newtonian multiphase slurries across various facilities managed by DOE. Particular emphasis during this workshop was placed on applications managed by the Office of Environmental Management (EM). The workshop was preceded by two webinars wherein personnel from ORP and NETL provided background information on the Hanford WTP projectmore » and discussed the critical design challenges facing this project. In non-Newtonian fluids, viscosity is not constant and exhibits a complex dependence on applied shear stress or deformation. Many applications under EM’s tank farm mission involve non-Newtonian slurries that are multiphase in nature; tank farm storage and handling, slurry transport, and mixing all involve multiphase flow dynamics, which require an improved understanding of the mechanisms responsible for rheological changes in non-Newtonian multiphase slurries (NNMS). To discuss the issues in predicting the behavior of NNMS, the workshop focused on two topic areas: (1) State-of-the-art in non-Newtonian Multiphase Slurry Flow, and (2) Scaling up with Confidence and Ensuring Safe and Reliable Long-Term Operation.« less

  6. Vision drives accurate approach behavior during prey capture in laboratory mice

    PubMed Central

    Hoy, Jennifer L.; Yavorska, Iryna; Wehr, Michael; Niell, Cristopher M.

    2016-01-01

    Summary The ability to genetically identify and manipulate neural circuits in the mouse is rapidly advancing our understanding of visual processing in the mammalian brain [1,2]. However, studies investigating the circuitry that underlies complex ethologically-relevant visual behaviors in the mouse have been primarily restricted to fear responses [3–5]. Here, we show that a laboratory strain of mouse (Mus musculus, C57BL/6J) robustly pursues, captures and consumes live insect prey, and that vision is necessary for mice to perform the accurate orienting and approach behaviors leading to capture. Specifically, we differentially perturbed visual or auditory input in mice and determined that visual input is required for accurate approach, allowing maintenance of bearing to within 11 degrees of the target on average during pursuit. While mice were able to capture prey without vision, the accuracy of their approaches and capture rate dramatically declined. To better explore the contribution of vision to this behavior, we developed a simple assay that isolated visual cues and simplified analysis of the visually guided approach. Together, our results demonstrate that laboratory mice are capable of exhibiting dynamic and accurate visually-guided approach behaviors, and provide a means to estimate the visual features that drive behavior within an ethological context. PMID:27773567

  7. Night Vision Laboratory Static Performance Model for Thermal Viewing Systems

    DTIC Science & Technology

    1975-04-01

    Research and Development Technical Report f ECOM-� • i’.__1’=• =•NIGHT VISION LABORATORY STATIC PERFORMANCE MODEL 1 S1=• : FOR THERMAL VIEWING...resolvable temperature Infrared imaging Minimum detectable temperature1.Detection and recognition performance Night visi,-)n Noise equivalent temperature...modulation transfer function (MTF). The noise charactcristics are specified by the noise equivalent temper- ature difference (NE AT), The next sections

  8. Field Test Report: NETL Portable Raman Gas Composition Monitor - Initial Industrial tests at NETL and General Electric (GE)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michael, Buric; Jessica, Mullen; Steven, Woodruff

    2012-02-24

    NETL has developed new technology which enables the use of Raman spectroscopy in the real-time measurement of gas mixtures. This technology uses a hollow reflective metal-lined capillary waveguide as a gas sampling cell which contains the sample gas, and efficiently collects optical Raman scattering from the gas sample, for measurement with a miniature spectrometer. The result is an optical Raman “fingerprint” for each gas which is tens or hundreds of times larger than that which can be collected with conventional free-space optics. In this manner, the new technology exhibits a combination of measurement speed and accuracy which is unprecedented formore » spontaneous Raman measurements of gases. This makes the system especially well-suited to gas turbine engine control based on a-priori measurement of incoming fuel composition. The system has been developed to produce a measurement of all of the common components of natural gas, including the lesser nitrogen, oxygen, carbon-dioxide, and carbon monoxide diluents to better than 1% concentration accuracy each second. The objective of this task under CRADA 10-N100 was to evaluate the capability of a laser Raman capillary gas sensor for combustion fuels. A portable version of the Raman gas sensor, constructed at NETL, was used for field-trials conducted in a cooperative research effort at a GE facility. Testing under the CRADA was performed in 5 parts. Parts 1-4 were successful in testing of the Raman Gas Composition Monitor with bottled calibration gases, and in continuous monitoring of several gas streams at low pressure, in comparison with an online mass spectrometer. In part 5, the Raman Gas Composition Monitor was moved outdoors for testing with high pressure gas supplies. Some difficulties were encountered during industrial testing including the condensation of heavy hydrocarbons inside the sample cell (in part 5), communication with the GE data collection system, as well as some drift in the optical noise

  9. U.S. DOE NETL methodology for estimating the prospective CO 2 storage resource of shales at the national and regional scale

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Levine, Jonathan S.; Fukai, Isis; Soeder, Daniel J.

    While the majority of shale formations will serve as reservoir seals for stored anthropogenic carbon dioxide (CO2), hydrocarbon-bearing shale formations may be potential geologic sinks after depletion through primary production. Here in this paper we present the United States-Department of Energy-National Energy Technology Laboratory (US-DOE-NETL) methodology for screening-level assessment of prospective CO 2 storage resources in shale using a volumetric equation. Volumetric resource estimates are produced from the bulk volume, porosity, and sorptivity of the shale and storage efficiency factors based on formation-scale properties and petrophysical limitations on fluid transport. Prospective shale formations require: (1) prior hydrocarbon production using horizontalmore » drilling and stimulation via staged, high-volume hydraulic fracturing, (2) depths sufficient to maintain CO 2 in a supercritical state, generally >800 m, and (3) an overlying seal. The US-DOE-NETL methodology accounts for storage of CO 2 in shale as a free fluid phase within fractures and matrix pores and as an sorbed phase on organic matter and clays. Uncertainties include but are not limited to poorly-constrained geologic variability in formation thickness, porosity, existing fluid content, organic richness, and mineralogy. Knowledge of how these parameters may be linked to depositional environments, facies, and diagenetic history of the shale will improve the understanding of pore-to-reservoir scale behavior, and provide improved estimates of prospective CO 2 storage.« less

  10. U.S. DOE NETL methodology for estimating the prospective CO 2 storage resource of shales at the national and regional scale

    DOE PAGES

    Levine, Jonathan S.; Fukai, Isis; Soeder, Daniel J.; ...

    2016-05-31

    While the majority of shale formations will serve as reservoir seals for stored anthropogenic carbon dioxide (CO2), hydrocarbon-bearing shale formations may be potential geologic sinks after depletion through primary production. Here in this paper we present the United States-Department of Energy-National Energy Technology Laboratory (US-DOE-NETL) methodology for screening-level assessment of prospective CO 2 storage resources in shale using a volumetric equation. Volumetric resource estimates are produced from the bulk volume, porosity, and sorptivity of the shale and storage efficiency factors based on formation-scale properties and petrophysical limitations on fluid transport. Prospective shale formations require: (1) prior hydrocarbon production using horizontalmore » drilling and stimulation via staged, high-volume hydraulic fracturing, (2) depths sufficient to maintain CO 2 in a supercritical state, generally >800 m, and (3) an overlying seal. The US-DOE-NETL methodology accounts for storage of CO 2 in shale as a free fluid phase within fractures and matrix pores and as an sorbed phase on organic matter and clays. Uncertainties include but are not limited to poorly-constrained geologic variability in formation thickness, porosity, existing fluid content, organic richness, and mineralogy. Knowledge of how these parameters may be linked to depositional environments, facies, and diagenetic history of the shale will improve the understanding of pore-to-reservoir scale behavior, and provide improved estimates of prospective CO 2 storage.« less

  11. The NETL MFiX Suite of multiphase flow models: A brief review and recent applications of MFiX-TFM to fossil energy technologies

    DOE PAGES

    Li, Tingwen; Rogers, William A.; Syamlal, Madhava; ...

    2016-07-29

    Here, the MFiX suite of multiphase computational fluid dynamics (CFD) codes is being developed at U.S. Department of Energy's National Energy Technology Laboratory (NETL). It includes several different approaches to multiphase simulation: MFiX-TFM, a two-fluid (Eulerian–Eulerian) model; MFiX-DEM, an Eulerian fluid model with a Lagrangian Discrete Element Model for the solids phase; and MFiX-PIC, Eulerian fluid model with Lagrangian particle ‘parcels’ representing particle groups. These models are undergoing continuous development and application, with verification, validation, and uncertainty quantification (VV&UQ) as integrated activities. After a brief summary of recent progress in the verification, validation and uncertainty quantification (VV&UQ), this article highlightsmore » two recent accomplishments in the application of MFiX-TFM to fossil energy technology development. First, recent application of MFiX to the pilot-scale KBR TRIG™ Transport Gasifier located at DOE's National Carbon Capture Center (NCCC) is described. Gasifier performance over a range of operating conditions was modeled and compared to NCCC operational data to validate the ability of the model to predict parametric behavior. Second, comparison of code predictions at a detailed fundamental scale is presented studying solid sorbents for the post-combustion capture of CO 2 from flue gas. Specifically designed NETL experiments are being used to validate hydrodynamics and chemical kinetics for the sorbent-based carbon capture process.« less

  12. Computation of turbulence and dispersion of cork in the NETL riser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiradilok, Veeraya; Gidaspow, Dimitri; Breault, R.W.

    The knowledge of dispersion coefficients is essential for reliable design of gasifiers. However, a literature review had shown that dispersion coefficients in fluidized beds differ by more than five orders of magnitude. This study presents a comparison of the computed axial solids dispersion coefficients for cork particles to the NETL riser cork data. The turbulence properties, the Reynolds stresses, the granular temperature spectra and the radial and axial gas and solids dispersion coefficients are computed. The standard kinetic theory model described in Gidaspow’s 1994 book, Multiphase Flow and Fluidization, Academic Press and the IIT and Fluent codes were used tomore » compute the measured axial solids volume fraction profiles for flow of cork particles in the NETL riser. The Johnson–Jackson boundary conditions were used. Standard drag correlations were used. This study shows that the computed solids volume fractions for the low flux flow are within the experimental error of those measured, using a two-dimensional model. At higher solids fluxes the simulated solids volume fractions are close to the experimental measurements, but deviate significantly at the top of the riser. This disagreement is due to use of simplified geometry in the two-dimensional simulation. There is a good agreement between the experiment and the three-dimensional simulation for a high flux condition. This study concludes that the axial and radial gas and solids dispersion coefficients in risers operating in the turbulent flow regime can be computed using a multiphase computational fluid dynamics model.« less

  13. Evaluation of Geothermal and Natural Gas Resources Beneath Camp Dawson and Opportunities for Deep Direct Use of Geothermal Energy or Natural Gas for Heat and Electricity Production; NETL-TRS-8-2017; NETL Technical Report Series; U.S. Department of Energy, National Energy Technology Laboratory: Morgantown, WV, 2017; p 148.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Means, Ken; Muring, Timothy M.; Sams, Neal W.

    NETL has reviewed available information and evaluated the deep geothermal and natural gas resources located beneath the Camp Dawson National Guard Training Center in West Virginia. This facility is located in the northeastern portion of the state in Preston County, near the town of Kingwood. This study reviews options for the onsite drilling of wells for the production of geothermal heat or natural gas, as well as the utilization of these resources for on-site power and heating needs. Resources of potential interest are at subsurface depths between 7,000 feet and 15,000 feet.

  14. Database and Analytical Tool Development for the Management of Data Derived from US DOE (NETL) Funded Fine Particulate (PM2.5) Research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson Khosah

    2007-07-31

    Advanced Technology Systems, Inc. (ATS) was contracted by the U. S. Department of Energy's National Energy Technology Laboratory (DOE-NETL) to develop a state-of-the-art, scalable and robust web-accessible database application to manage the extensive data sets resulting from the DOE-NETL-sponsored ambient air monitoring programs in the upper Ohio River valley region. The data management system was designed to include a web-based user interface that will allow easy access to the data by the scientific community, policy- and decision-makers, and other interested stakeholders, while providing detailed information on sampling, analytical and quality control parameters. In addition, the system will provide graphical analyticalmore » tools for displaying, analyzing and interpreting the air quality data. The system will also provide multiple report generation capabilities and easy-to-understand visualization formats that can be utilized by the media and public outreach/educational institutions. The project was conducted in two phases. Phase One included the following tasks: (1) data inventory/benchmarking, including the establishment of an external stakeholder group; (2) development of a data management system; (3) population of the database; (4) development of a web-based data retrieval system, and (5) establishment of an internal quality assurance/quality control system on data management. Phase Two involved the development of a platform for on-line data analysis. Phase Two included the following tasks: (1) development of a sponsor and stakeholder/user website with extensive online analytical tools; (2) development of a public website; (3) incorporation of an extensive online help system into each website; and (4) incorporation of a graphical representation (mapping) system into each website. The project is now technically completed.« less

  15. NETL to establish Dynamic Simulation Research and Training Center to promote IGCC technology with CO2 cpture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Provost, G.; Zitney, S.; Turton, R.

    2009-01-01

    To meet increasing demand for education and experience with commercial-scale, coal-fired, integrated gasification combined cycle (IGCC) plants with CO2 capture, the Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) is leading a project to deploy a generic, full-scope, real-time IGCC dynamic plant simulator for use in establishing a world-class research and training center, and to promote and demonstrate IGCC technology to power industry personnel. The simulator, being built by Invensys Process Systems (IPS), will be installed at two separate sites, at NETL and West Virginia University (WVU), and will combine a process/gasification simulator with a power/combined-cycle simulator together inmore » a single dynamic simulation framework for use in engineering research studies and training applications. The simulator, scheduled to be launched in mid-year 2010, will have the following capabilities: High-fidelity, dynamic model of process-side (gasification and gas cleaning with CO2 capture) and power-block-side (combined cycle) for a generic IGCC plant fueled by coal and/or petroleum coke. Highly flexible configuration that allows concurrent training on separate gasification and combined cycle simulators, or up to two IGCC simulators. Ability to enhance and modify the plant model to facilitate studies of changes in plant configuration, equipment, and control strategies to support future R&D efforts. Training capabilities including startup, shutdown, load following and shedding, response to fuel and ambient condition variations, control strategy analysis (turbine vs. gasifier lead, etc.), representative malfunctions/trips, alarms, scenarios, trending, snapshots, data historian, etc. To support this effort, process descriptions and control strategies were developed for key sections of the plant as part of the detailed functional specification, which is serving as the basis of the simulator development. In this paper, we highlight the contents of

  16. Abstract - Cooperative Research and Development Agreement between Ames National Laboratory and National Energy Technology Laboratory AGMT-0609

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bryden, Mark; Tucker, David A.

    The goal of this project is to develop a merged environment for simulation and analysis (MESA) at the National Energy Technology Laboratory’s (NETL) Hybrid Performance (Hyper) project laboratory. The MESA sensor lab developed as a component of this research will provide a development platform for investigating: 1) advanced control strategies, 2) testing and development of sensor hardware, 3) various modeling in-the-loop algorithms and 4) other advanced computational algorithms for improved plant performance using sensors, real-time models, and complex systems tools.

  17. Database and Analytical Tool Development for the Management of Data Derived from US DOE (NETL) Funded Fine Particulate (PM2.5) Research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson P. Khosah; Frank T. Alex

    2007-02-11

    Advanced Technology Systems, Inc. (ATS) was contracted by the U. S. Department of Energy's National Energy Technology Laboratory (DOE-NETL) to develop a state-of-the-art, scalable and robust web-accessible database application to manage the extensive data sets resulting from the DOE-NETL-sponsored ambient air monitoring programs in the upper Ohio River valley region. The data management system was designed to include a web-based user interface that will allow easy access to the data by the scientific community, policy- and decision-makers, and other interested stakeholders, while providing detailed information on sampling, analytical and quality control parameters. In addition, the system will provide graphical analyticalmore » tools for displaying, analyzing and interpreting the air quality data. The system will also provide multiple report generation capabilities and easy-to-understand visualization formats that can be utilized by the media and public outreach/educational institutions. The project is being conducted in two phases. Phase One includes the following tasks: (1) data inventory/benchmarking, including the establishment of an external stakeholder group; (2) development of a data management system; (3) population of the database; (4) development of a web-based data retrieval system, and (5) establishment of an internal quality assurance/quality control system on data management. Phase Two, which is currently underway, involves the development of a platform for on-line data analysis. Phase Two includes the following tasks: (1) development of a sponsor and stakeholder/user website with extensive online analytical tools; (2) development of a public website; (3) incorporation of an extensive online help system into each website; and (4) incorporation of a graphical representation (mapping) system into each website. The project is now into its forty-eighth month of development activities.« less

  18. DATABASE AND ANALYTICAL TOOL DEVELOPMENT FOR THE MANAGEMENT OF DATA DERIVED FROM US DOE (NETL) FUNDED FINE PARTICULATE (PM 2.5) RESEARCH

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson P. Khosah; Charles G. Crawford

    2006-02-11

    Advanced Technology Systems, Inc. (ATS) was contracted by the U. S. Department of Energy's National Energy Technology Laboratory (DOE-NETL) to develop a state-of-the-art, scalable and robust web-accessible database application to manage the extensive data sets resulting from the DOE-NETL-sponsored ambient air monitoring programs in the upper Ohio River valley region. The data management system was designed to include a web-based user interface that will allow easy access to the data by the scientific community, policy- and decision-makers, and other interested stakeholders, while providing detailed information on sampling, analytical and quality control parameters. In addition, the system will provide graphical analyticalmore » tools for displaying, analyzing and interpreting the air quality data. The system will also provide multiple report generation capabilities and easy-to-understand visualization formats that can be utilized by the media and public outreach/educational institutions. The project is being conducted in two phases. Phase One includes the following tasks: (1) data inventory/benchmarking, including the establishment of an external stakeholder group; (2) development of a data management system; (3) population of the database; (4) development of a web-based data retrieval system, and (5) establishment of an internal quality assurance/quality control system on data management. Phase Two, which is currently underway, involves the development of a platform for on-line data analysis. Phase Two includes the following tasks: (1) development of a sponsor and stakeholder/user website with extensive online analytical tools; (2) development of a public website; (3) incorporation of an extensive online help system into each website; and (4) incorporation of a graphical representation (mapping) system into each website. The project is now into its forty-second month of development activities.« less

  19. Vision 2030. A Vision for the U.S. Concrete Industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2001-01-01

    On September 27, 2000, the concrete industry's Strategic Development Council hosted a Concrete Vision Workshop in Chicago, Illinois. Meeting participants included over 50 concrete, cement, and other allied industry chief executive officers, presidents, vice-presidents, laboratory and industry research managers, and government representatives. Participants discussed the state of the concrete industry 30 years ago, the state of the current industry, and their vision for the United States concrete industry in 2030. Moreover, they identified specific goals to achieve the industry's Vision 2030. This document, Vision 2030, is the product of that workshop and the comments received after a broad industry review.

  20. MFIX simulation of NETL/PSRI challenge problem of circulating fluidized bed

    DOE PAGES

    Li, Tingwen; Dietiker, Jean-François; Shahnam, Mehrdad

    2012-12-01

    In this paper, numerical simulations of NETL/PSRI challenge problem of circulating fluidized bed (CFB) using the open-source code Multiphase Flow with Interphase eXchange (MFIX) are reported. Two rounds of simulation results are reported including the first-round blind test and the second-round modeling refinement. Three-dimensional high fidelity simulations are conducted to model a 12-inch diameter pilot-scale CFB riser. Detailed comparisons between numerical results and experimental data are made with respect to axial pressure gradient profile, radial profiles of solids velocity and solids mass flux along different radial directions at various elevations for operating conditions covering different fluidization regimes. Overall, the numericalmore » results show that CFD can predict the complex gas–solids flow behavior in the CFB riser reasonably well. In addition, lessons learnt from modeling this challenge problem are presented.« less

  1. Prospective CO 2 saline resource estimation methodology: Refinement of existing US-DOE-NETL methods based on data availability

    DOE PAGES

    Goodman, Angela; Sanguinito, Sean; Levine, Jonathan S.

    2016-09-28

    Carbon storage resource estimation in subsurface saline formations plays an important role in establishing the scale of carbon capture and storage activities for governmental policy and commercial project decision-making. Prospective CO 2 resource estimation of large regions or subregions, such as a basin, occurs at the initial screening stages of a project using only limited publicly available geophysical data, i.e. prior to project-specific site selection data generation. As the scale of investigation is narrowed and selected areas and formations are identified, prospective CO 2 resource estimation can be refined and uncertainty narrowed when site-specific geophysical data are available. Here, wemore » refine the United States Department of Energy – National Energy Technology Laboratory (US-DOE-NETL) methodology as the scale of investigation is narrowed from very large regional assessments down to selected areas and formations that may be developed for commercial storage. In addition, we present a new notation that explicitly identifies differences between data availability and data sources used for geologic parameters and efficiency factors as the scale of investigation is narrowed. This CO 2 resource estimation method is available for screening formations in a tool called CO 2-SCREEN.« less

  2. Prospective CO 2 saline resource estimation methodology: Refinement of existing US-DOE-NETL methods based on data availability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goodman, Angela; Sanguinito, Sean; Levine, Jonathan S.

    Carbon storage resource estimation in subsurface saline formations plays an important role in establishing the scale of carbon capture and storage activities for governmental policy and commercial project decision-making. Prospective CO 2 resource estimation of large regions or subregions, such as a basin, occurs at the initial screening stages of a project using only limited publicly available geophysical data, i.e. prior to project-specific site selection data generation. As the scale of investigation is narrowed and selected areas and formations are identified, prospective CO 2 resource estimation can be refined and uncertainty narrowed when site-specific geophysical data are available. Here, wemore » refine the United States Department of Energy – National Energy Technology Laboratory (US-DOE-NETL) methodology as the scale of investigation is narrowed from very large regional assessments down to selected areas and formations that may be developed for commercial storage. In addition, we present a new notation that explicitly identifies differences between data availability and data sources used for geologic parameters and efficiency factors as the scale of investigation is narrowed. This CO 2 resource estimation method is available for screening formations in a tool called CO 2-SCREEN.« less

  3. DOE/NETL's phase II mercury control technology field testing program: preliminary economic analysis of activated carbon injection.

    PubMed

    Jones, Andrew P; Hoffmann, Jeffrey W; Smith, Dennis N; Feeley, Thomas J; Murphy, James T

    2007-02-15

    Based on results of field testing conducted by the U.S. Department of Energy's National Energy Technology Laboratory (DOE/NETL), this article provides preliminary costs for mercury control via conventional activated carbon injection (ACI), brominated ACI, and conventional ACI coupled with the application of a sorbent enhancement additive (SEA) to coal prior to combustion. The economic analyses are reported on a plant-specific basis in terms of the cost required to achieve low (50%), mid (70%), and high (90%) levels of mercury removal "above and beyond" the baseline mercury removal achieved by existing emission control equipment. In other words, the levels of mercury control are directly attributable to ACI. Mercury control costs via ACI have been amortized on a current dollar basis. Using a 20-year book life, levelized costs for the incremental increase in cost of electricity (COE), expressed in mills per kilowatt-hour (mills/kWh), and the incremental cost of mercury control, expressed in dollars per pound of mercury removed ($/lb Hg removed), have been calculated for each level of ACI mercury control. For this analysis, the increase in COE varied from 0.14 mills/kWh to 3.92 mills/kWh. Meanwhile, the incremental cost of mercury control ranged from $3810/lb Hg removed to $166000/lb Hg removed.

  4. DATABASE AND ANALYTICAL TOOL DEVELOPMENT FOR THE MANAGEMENT OF DATA DERIVED FROM US DOE (NETL) FUNDED FINE PARTICULATE (PM2.5) RESEARCH

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson P. Khosah; Charles G. Crawford

    Advanced Technology Systems, Inc. (ATS) was contracted by the U. S. Department of Energy's National Energy Technology Laboratory (DOE-NETL) to develop a state-of-the-art, scalable and robust web-accessible database application to manage the extensive data sets resulting from the DOE-NETL-sponsored ambient air monitoring programs in the upper Ohio River valley region. The data management system was designed to include a web-based user interface that will allow easy access to the data by the scientific community, policy- and decision-makers, and other interested stakeholders, while providing detailed information on sampling, analytical and quality control parameters. In addition, the system will provide graphical analyticalmore » tools for displaying, analyzing and interpreting the air quality data. The system will also provide multiple report generation capabilities and easy-to-understand visualization formats that can be utilized by the media and public outreach/educational institutions. The project is being conducted in two phases. Phase 1, which is currently in progress and will take twelve months to complete, will include the following tasks: (1) data inventory/benchmarking, including the establishment of an external stakeholder group; (2) development of a data management system; (3) population of the database; (4) development of a web-based data retrieval system, and (5) establishment of an internal quality assurance/quality control system on data management. In Phase 2, which will be completed in the second year of the project, a platform for on-line data analysis will be developed. Phase 2 will include the following tasks: (1) development of a sponsor and stakeholder/user website with extensive online analytical tools; (2) development of a public website; (3) incorporation of an extensive online help system into each website; and (4) incorporation of a graphical representation (mapping) system into each website. The project is now into its eleventh month of

  5. Vision and Driving

    PubMed Central

    Owsley, Cynthia; McGwin, Gerald

    2010-01-01

    Driving is the primary means of personal travel in many countries and is relies heavily on vision for its successful execution. Research over the past few decades has addressed the role of vision in driver safety (motor vehicle collision involvement) and in driver performance (both on-road and using interactive simulators in the laboratory). Here we critically review what is currently known about the role of various aspects of visual function in driving. We also discuss translational research issues on vision screening for licensure and re-licensure and rehabilitation of visually impaired persons who want to drive. PMID:20580907

  6. Dynamical Systems and Motion Vision.

    DTIC Science & Technology

    1988-04-01

    TASK Artificial Inteligence Laboratory AREA I WORK UNIT NUMBERS 545 Technology Square . Cambridge, MA 02139 C\\ II. CONTROLLING OFFICE NAME ANO0 ADDRESS...INSTITUTE OF TECHNOLOGY ARTIFICIAL INTELLIGENCE LABORATORY A.I.Memo No. 1037 April, 1988 Dynamical Systems and Motion Vision Joachim Heel Abstract: In this... Artificial Intelligence L3 Laboratory of the Massachusetts Institute of Technology. Support for the Laboratory’s [1 Artificial Intelligence Research is

  7. Ultraviolet vision may be widespread in bats

    USGS Publications Warehouse

    Gorresen, P. Marcos; Cryan, Paul; Dalton, David C.; Wolf, Sandy; Bonaccorso, Frank

    2015-01-01

    Insectivorous bats are well known for their abilities to find and pursue flying insect prey at close range using echolocation, but they also rely heavily on vision. For example, at night bats use vision to orient across landscapes, avoid large obstacles, and locate roosts. Although lacking sharp visual acuity, the eyes of bats evolved to function at very low levels of illumination. Recent evidence based on genetics, immunohistochemistry, and laboratory behavioral trials indicated that many bats can see ultraviolet light (UV), at least at illumination levels similar to or brighter than those before twilight. Despite this growing evidence for potentially widespread UV vision in bats, the prevalence of UV vision among bats remains unknown and has not been studied outside of the laboratory. We used a Y-maze to test whether wild-caught bats could see reflected UV light and whether such UV vision functions at the dim lighting conditions typically experienced by night-flying bats. Seven insectivorous species of bats, representing five genera and three families, showed a statistically significant ‘escape-toward-the-light’ behavior when placed in the Y-maze. Our results provide compelling evidence of widespread dim-light UV vision in bats.

  8. Night Vision Camera

    NASA Technical Reports Server (NTRS)

    1996-01-01

    PixelVision, Inc. developed the Night Video NV652 Back-illuminated CCD Camera, based on the expertise of a former Jet Propulsion Laboratory employee and a former employee of Scientific Imaging Technologies, Inc. The camera operates without an image intensifier, using back-illuminated and thinned CCD technology to achieve extremely low light level imaging performance. The advantages of PixelVision's system over conventional cameras include greater resolution and better target identification under low light conditions, lower cost and a longer lifetime. It is used commercially for research and aviation.

  9. Aural-Nondetectability Model Predictions for Night-Vision Goggles across Ambient Lighting Conditions

    DTIC Science & Technology

    2015-12-01

    ARL-TR-7564 ● DEC 2015 US Army Research Laboratory Aural-Nondetectability Model Predictions for Night -Vision Goggles across...ARL-TR-7564 ● DEC 2015 US Army Research Laboratory Aural-Nondetectability Model Predictions for Night -Vision Goggles across Ambient...May 2015–30 Sep 2015 4. TITLE AND SUBTITLE Aural-Nondetectability Model Predictions for Night -Vision Goggles across Ambient Lighting Conditions 5a

  10. A Unified Taxonomic Approach to the Laboratory Assessment of Visionic Devices

    DTIC Science & Technology

    2006-09-01

    the ratification stage with member nations. Marasco and Task 4 presented a large array of tests applicable to image intensification-based visionic...aircraft.” In print. 4. Marasco , P. L., and Task, H. L. 1999. “Optical characterization of wide field-of-view night vision devices,” in

  11. A Vision-Based Motion Sensor for Undergraduate Laboratories.

    ERIC Educational Resources Information Center

    Salumbides, Edcel John; Maristela, Joyce; Uy, Alfredson; Karremans, Kees

    2002-01-01

    Introduces an alternative method to determine the mechanics of a moving object that uses computer vision algorithms with a charge-coupled device (CCD) camera as a recording device. Presents two experiments, pendulum motion and terminal velocity, to compare results of the alternative and conventional methods. (YDS)

  12. Annual Report: Unconventional Fossil Energy Resource Program (30 September 2013)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Soong, Yee; Guthrie, George

    2013-09-30

    Yee Soong, Technical Coordinator, George Guthrie, Focus Area Lead, UFER Annual Report, NETL-TRS-UFER-2013, NETL Technical Report Series, U.S. Department of Energy, National Energy Technology Laboratory, Pittsburgh, PA, 2013, p 14.

  13. Physical property studies in the USGS GHASTLI Laboratory

    USGS Publications Warehouse

    Winters, William J.; Waite, William F.; Hutchinson, Deborah R.; Mason, David H.

    2008-01-01

    One of the many challenges in studying methane hydrate is that it is unstable at typical surface pressure and temperature conditions. To enable methane hydrates and hydrate-bearing sediments to be formed, analyzed, and experimented with, the National Energy Technology Laboratory (NETL), and the U.S. Geological Survey (USGS) in Woods Hole, MA collaborated in the development of the Gas Hydrate And Sediment Test Laboratory Instrument (GHASTLI). Over the past decade, the USGS has been operating GHASTLI and collaborating in the development of new sample handling tools and procedures, in an effort to improve our ability to analyze methane hydrate in the lab. These tools will enable hydrate researchers to more confidently link field studies (for example geophysics or drilling) with theoretical and predictive studies, leading to a better understanding of the geological conditions and processes that control the growth and concentration of natural gas hydrates, how hydrates affect the properties of the host sediments, and how the hydrate-sediment system changes when hydrate dissociates and releases the previously bound gas. To date, GHASTLI has been used to measure natural samples from ODP Leg 164 (Blake Ridge off the U.S. southeast Atlantic margin), Leg 204 (Hydrate Ridge off the Pacific Northwest margin) and the Mallik well (Mackenzie Delta in northwestern Canada). Additional samples in the queue for analysis are from the Chevron Joint Industry Project Experiment in the Gulf of Mexico and most recently, from IODP Leg 311 off Vancouver Island. Several foreign nations have asked whether GHASTLI will be available to analyze samples that might be recovered during national drilling programs. The ability to perform lab testing of hydrates within sediments is one of the unique capabilities of GHASTLI that separates it from other simulators at NETL and elsewhere.

  14. Operation of the NETL Chemical Looping Reactor with Natural Gas and a Novel Copper-Iron Material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Straub, Douglas; Bayham, Samuel; Weber, Justin

    The proposed Clean Power Plan requires CO 2 emission reductions of 30% by 2030 and further reductions are targeted by 2050. The current strategies to achieve the 30% reduction targets do not include options for coal. However, the 2016 Annual Energy Outlook suggests that coal will continue to provide more electricity than renewable sources for many regions of the country in 2035. Therefore, cost effective options to reduce greenhouse gas emissions from fossil fuel power plants are vital in order to achieve greenhouse gas reduction targets beyond 2030. As part of the U.S. Department of Energy’s Advanced Combustion Program, themore » National Energy Technology Laboratory’s Research and Innovation Center (NETL R&IC) is investigating the feasibility of a novel combustion concept in which the GHG emissions can be significantly reduced. This concept involves burning fuel and air without mixing these two reactants. If this concept is technically feasible, then CO 2 emissions can be significantly reduced at a much lower cost than more conventional approaches. This indirect combustion concept has been called Chemical Looping Combustion (CLC) because an intermediate material (i.e., a metal-oxide) is continuously cycled to oxidize the fuel. This CLC concept is the focus of this research and will be described in more detail in the following sections. The solid material that is used to transport oxygen is called an oxygen carrier material. The cost, durability, and performance of this material is a key issue for the CLC technology. Researchers at the NETL R&IC have developed an oxygen carrier material that consists of copper, iron, and alumina. This material has been tested extensively using lab scale instruments such as thermogravimetric analysis (TGA), scanning electron microscopy (SEM), mechanical attrition (ASTM D5757), and small fluidized bed reactor tests. This report will describe the results from a realistic, circulating, proof-of-concept test that was completed

  15. MOBLAB: a mobile laboratory for testing real-time vision-based systems in path monitoring

    NASA Astrophysics Data System (ADS)

    Cumani, Aldo; Denasi, Sandra; Grattoni, Paolo; Guiducci, Antonio; Pettiti, Giuseppe; Quaglia, Giorgio

    1995-01-01

    In the framework of the EUREKA PROMETHEUS European Project, a Mobile Laboratory (MOBLAB) has been equipped for studying, implementing and testing real-time algorithms which monitor the path of a vehicle moving on roads. Its goal is the evaluation of systems suitable to map the position of the vehicle within the environment where it moves, to detect obstacles, to estimate motion, to plan the path and to warn the driver about unsafe conditions. MOBLAB has been built with the financial support of the National Research Council and will be shared with teams working in the PROMETHEUS Project. It consists of a van equipped with an autonomous power supply, a real-time image processing system, workstations and PCs, B/W and color TV cameras, and TV equipment. This paper describes the laboratory outline and presents the computer vision system and the strategies that have been studied and are being developed at I.E.N. `Galileo Ferraris'. The system is based on several tasks that cooperate to integrate information gathered from different processes and sources of knowledge. Some preliminary results are presented showing the performances of the system.

  16. Operation of the NETL Chemical Looping Reactor with Natural Gas and a Novel Copper-Iron Material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bayham, Sanuel; Straub, Doug; Weber, Justin

    2017-02-01

    As part of the U.S. Department of Energy’s Advanced Combustion Program, the National Energy Technology Laboratory’s Research and Innovation Center (NETL R&IC) is investigating the feasibility of a novel combustion concept in which the GHG emissions can be significantly reduced. This concept involves burning fuel and air without mixing these two reactants. If this concept is technically feasible, then CO 2 emissions can be significantly reduced at a much lower cost than more conventional approaches. This indirect combustion concept has been called Chemical Looping Combustion (CLC) because an intermediate material (i.e., a metaloxide) is continuously cycled to oxidize the fuel.more » This CLC concept is the focus of this research and will be described in more detail in the following sections.« less

  17. GeoVision Exploration Task Force Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doughty, Christine; Dobson, Patrick F.; Wall, Anna

    The GeoVision study effort included ground-breaking, detailed research on current and future market conditions and geothermal technologies in order to forecast and quantify the electric and non-electric deployment potentials under a range of scenarios, in addition to their impacts on the Nation’s jobs, economy and environment. Coordinated by the U.S. Department of Energy’s (DOE’s) Geothermal Technologies Office (GTO), the GeoVision study development relied on the collection, modeling, and analysis of robust datasets through seven national laboratory partners, which were organized into eight technical Task Force groups. The purpose of this report is to provide a central repository for the researchmore » conducted by the Exploration Task Force. The Exploration Task Force consists of four individuals representing three national laboratories: Patrick Dobson (task lead) and Christine Doughty of Lawrence Berkeley National Laboratory, Anna Wall of National Renewable Energy Laboratory, Travis McLing of Idaho National Laboratory, and Chester Weiss of Sandia National Laboratories. As part of the GeoVision analysis, our team conducted extensive scientific and financial analyses on a number of topics related to current and future geothermal exploration methods. The GeoVision Exploration Task Force complements the drilling and resource technology investigations conducted as part of the Reservoir Maintenance and Development Task Force. The Exploration Task Force however has focused primarily on early stage R&D technologies in exploration and confirmation drilling, along with an evaluation of geothermal financing challenges and assumptions, and innovative “blue-sky” technologies. This research was used to develop geothermal resource supply curves (through the use of GETEM) for use in the ReEDS capacity expansion modeling that determines geothermal technology deployment potential. It also catalogues and explores the large array of early-stage R&D technologies with the

  18. Availability of vision and tactile gating: vision enhances tactile sensitivity.

    PubMed

    Colino, Francisco L; Lee, Ji-Hang; Binsted, Gordon

    2017-01-01

    A multitude of events bombard our sensory systems at every moment of our lives. Thus, it is important for the sensory and motor cortices to gate unimportant events. Tactile suppression is a well-known phenomenon defined as a reduced ability to detect tactile events on the skin before and during movement. Previous experiments (Buckingham et al. in Exp Brain Res 201(3):411-419, 2010; Colino et al. in Physiol Rep 2(3):e00267, 2014) found detection rates decrease just prior to and during finger abduction and decrease according to the proximity of the moving effector. However, what effect does vision have on tactile gating? There is ample evidence (see Serino and Haggard in Neurosci Biobehav Rev 34:224-236, 2010) observing increased tactile acuity when participants see their limbs. The present study examined how tactile detection changes in response to visual condition (vision/no vision). Ten human participants used their right hand to reach and grasp a cylinder. Tactors were attached to the index finger and the forearm of both the right and left arm and vibrated at various epochs relative to a "go" tone. Results replicate previous findings from our laboratory (Colino et al. in Physiol Rep 2(3):e00267, 2014). Also, tactile acuity decreased when participants did not have vision. These results indicate that the vision affects the somatosensation via inputs from parietal areas (Konen and Haggard in Cereb Cortex 24(2):501-507, 2014) but does so in a reach-to-grasp context.

  19. NETL CO 2 Storage prospeCtive Resource Estimation Excel aNalysis (CO 2-SCREEN) User's Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanguinito, Sean M.; Goodman, Angela; Levine, Jonathan

    This user’s manual guides the use of the National Energy Technology Laboratory’s (NETL) CO 2 Storage prospeCtive Resource Estimation Excel aNalysis (CO 2-SCREEN) tool, which was developed to aid users screening saline formations for prospective CO 2 storage resources. CO 2- SCREEN applies U.S. Department of Energy (DOE) methods and equations for estimating prospective CO 2 storage resources for saline formations. CO2-SCREEN was developed to be substantive and user-friendly. It also provides a consistent method for calculating prospective CO 2 storage resources that allows for consistent comparison of results between different research efforts, such as the Regional Carbon Sequestration Partnershipsmore » (RCSP). CO 2-SCREEN consists of an Excel spreadsheet containing geologic inputs and outputs, linked to a GoldSim Player model that calculates prospective CO 2 storage resources via Monte Carlo simulation.« less

  20. Knowledge-based machine vision systems for space station automation

    NASA Technical Reports Server (NTRS)

    Ranganath, Heggere S.; Chipman, Laure J.

    1989-01-01

    Computer vision techniques which have the potential for use on the space station and related applications are assessed. A knowledge-based vision system (expert vision system) and the development of a demonstration system for it are described. This system implements some of the capabilities that would be necessary in a machine vision system for the robot arm of the laboratory module in the space station. A Perceptics 9200e image processor, on a host VAXstation, was used to develop the demonstration system. In order to use realistic test images, photographs of actual space shuttle simulator panels were used. The system's capabilities of scene identification and scene matching are discussed.

  1. Neural Networks for Computer Vision: A Framework for Specifications of a General Purpose Vision System

    NASA Astrophysics Data System (ADS)

    Skrzypek, Josef; Mesrobian, Edmond; Gungner, David J.

    1989-03-01

    The development of autonomous land vehicles (ALV) capable of operating in an unconstrained environment has proven to be a formidable research effort. The unpredictability of events in such an environment calls for the design of a robust perceptual system, an impossible task requiring the programming of a system bases on the expectation of future, unconstrained events. Hence, the need for a "general purpose" machine vision system that is capable of perceiving and understanding images in an unconstrained environment in real-time. The research undertaken at the UCLA Machine Perception Laboratory addresses this need by focusing on two specific issues: 1) the long term goals for machine vision research as a joint effort between the neurosciences and computer science; and 2) a framework for evaluating progress in machine vision. In the past, vision research has been carried out independently within different fields including neurosciences, psychology, computer science, and electrical engineering. Our interdisciplinary approach to vision research is based on the rigorous combination of computational neuroscience, as derived from neurophysiology and neuropsychology, with computer science and electrical engineering. The primary motivation behind our approach is that the human visual system is the only existing example of a "general purpose" vision system and using a neurally based computing substrate, it can complete all necessary visual tasks in real-time.

  2. Colour calibration of a laboratory computer vision system for quality evaluation of pre-sliced hams.

    PubMed

    Valous, Nektarios A; Mendoza, Fernando; Sun, Da-Wen; Allen, Paul

    2009-01-01

    Due to the high variability and complex colour distribution in meats and meat products, the colour signal calibration of any computer vision system used for colour quality evaluations, represents an essential condition for objective and consistent analyses. This paper compares two methods for CIE colour characterization using a computer vision system (CVS) based on digital photography; namely the polynomial transform procedure and the transform proposed by the sRGB standard. Also, it presents a procedure for evaluating the colour appearance and presence of pores and fat-connective tissue on pre-sliced hams made from pork, turkey and chicken. Our results showed high precision, in colour matching, for device characterization when the polynomial transform was used to match the CIE tristimulus values in comparison with the sRGB standard approach as indicated by their ΔE(ab)(∗) values. The [3×20] polynomial transfer matrix yielded a modelling accuracy averaging below 2.2 ΔE(ab)(∗) units. Using the sRGB transform, high variability was appreciated among the computed ΔE(ab)(∗) (8.8±4.2). The calibrated laboratory CVS, implemented with a low-cost digital camera, exhibited reproducible colour signals in a wide range of colours capable of pinpointing regions-of-interest and allowed the extraction of quantitative information from the overall ham slice surface with high accuracy. The extracted colour and morphological features showed potential for characterizing the appearance of ham slice surfaces. CVS is a tool that can objectively specify colour and appearance properties of non-uniformly coloured commercial ham slices.

  3. Brain-computer interaction research at the Computer Vision and Multimedia Laboratory, University of Geneva.

    PubMed

    Pun, Thierry; Alecu, Teodor Iulian; Chanel, Guillaume; Kronegg, Julien; Voloshynovskiy, Sviatoslav

    2006-06-01

    This paper describes the work being conducted in the domain of brain-computer interaction (BCI) at the Multimodal Interaction Group, Computer Vision and Multimedia Laboratory, University of Geneva, Geneva, Switzerland. The application focus of this work is on multimodal interaction rather than on rehabilitation, that is how to augment classical interaction by means of physiological measurements. Three main research topics are addressed. The first one concerns the more general problem of brain source activity recognition from EEGs. In contrast with classical deterministic approaches, we studied iterative robust stochastic based reconstruction procedures modeling source and noise statistics, to overcome known limitations of current techniques. We also developed procedures for optimal electroencephalogram (EEG) sensor system design in terms of placement and number of electrodes. The second topic is the study of BCI protocols and performance from an information-theoretic point of view. Various information rate measurements have been compared for assessing BCI abilities. The third research topic concerns the use of EEG and other physiological signals for assessing a user's emotional status.

  4. The Next Generation Laboratory Interface for Students with Blindness or Low Vision in the Science Laboratory

    ERIC Educational Resources Information Center

    Supalo, Cary A.

    2012-01-01

    Entry into science education for students with blindness or low vision can present economic and technological barriers to access. This manuscript discusses funding hands-on student experiences in middle school, high school, and post-secondary education. Further, the use of access technologies recently developed for science education is also…

  5. Merged Vision and GPS Control of a Semi-Autonomous, Small Helicopter

    NASA Technical Reports Server (NTRS)

    Rock, Stephen M.

    1999-01-01

    This final report documents the activities performed during the research period from April 1, 1996 to September 30, 1997. It contains three papers: Carrier Phase GPS and Computer Vision for Control of an Autonomous Helicopter; A Contestant in the 1997 International Aerospace Robotics Laboratory Stanford University; and Combined CDGPS and Vision-Based Control of a Small Autonomous Helicopter.

  6. Experiences Using an Open Source Software Library to Teach Computer Vision Subjects

    ERIC Educational Resources Information Center

    Cazorla, Miguel; Viejo, Diego

    2015-01-01

    Machine vision is an important subject in computer science and engineering degrees. For laboratory experimentation, it is desirable to have a complete and easy-to-use tool. In this work we present a Java library, oriented to teaching computer vision. We have designed and built the library from the scratch with emphasis on readability and…

  7. Automated vision occlusion-timing instrument for perception-action research.

    PubMed

    Brenton, John; Müller, Sean; Rhodes, Robbie; Finch, Brad

    2018-02-01

    Vision occlusion spectacles are a highly valuable instrument for visual-perception-action research in a variety of disciplines. In sports, occlusion spectacles have enabled invaluable knowledge to be obtained about the superior capability of experts to use visual information to guide actions within in-situ settings. Triggering the spectacles to occlude a performer's vision at a precise time in an opponent's action or object flight has been problematic, due to experimenter error in using a manual buttonpress approach. This article describes a new laser curtain wireless trigger for vision occlusion spectacles that is portable and fast in terms of its transmission time. The laser curtain can be positioned in a variety of orientations to accept a motion trigger, such as a cricket bowler's arm that distorts the lasers, which then activates a wireless signal for the occlusion spectacles to change from transparent to opaque, which occurs in only 8 ms. Results are reported from calculations done in an electronics laboratory, as well as from tests in a performance laboratory with a cricket bowler and a baseball pitcher, which verified this short time delay before vision occlusion. In addition, our results show that occlusion consistently occurred when it was intended-that is, near ball release and during mid-ball-flight. Only 8% of the collected data trials were unusable. The laser curtain improves upon the limitations of existing vision occlusion spectacle triggers, indicating that it is a valuable instrument for perception-action research in a variety of disciplines.

  8. The role of vision processing in prosthetic vision.

    PubMed

    Barnes, Nick; He, Xuming; McCarthy, Chris; Horne, Lachlan; Kim, Junae; Scott, Adele; Lieby, Paulette

    2012-01-01

    Prosthetic vision provides vision which is reduced in resolution and dynamic range compared to normal human vision. This comes about both due to residual damage to the visual system from the condition that caused vision loss, and due to limitations of current technology. However, even with limitations, prosthetic vision may still be able to support functional performance which is sufficient for tasks which are key to restoring independent living and quality of life. Here vision processing can play a key role, ensuring that information which is critical to the performance of key tasks is available within the capability of the available prosthetic vision. In this paper, we frame vision processing for prosthetic vision, highlight some key areas which present problems in terms of quality of life, and present examples where vision processing can help achieve better outcomes.

  9. Color Vision in Color Display Night Vision Goggles.

    PubMed

    Liggins, Eric P; Serle, William P

    2017-05-01

    Aircrew viewing eyepiece-injected symbology on color display night vision goggles (CDNVGs) are performing a visual task involving color under highly unnatural viewing conditions. Their performance in discriminating different colors and responding to color cues is unknown. Experimental laboratory measurements of 1) color discrimination and 2) visual search performance are reported under adaptation conditions representative of a CDNVG. Color discrimination was measured using a two-alternative forced choice (2AFC) paradigm that probes color space uniformly around a white point. Search times in the presence of different degrees of clutter (distractors in the scene) are measured for different potential symbology colors. The discrimination data support previous data suggesting that discrimination is best for colors close to the adapting point in color space (P43 phosphor in this case). There were highly significant effects of background adaptation (white or green) and test color. The search time data show that saturated colors with the greatest chromatic contrast with respect to the background lead to the shortest search times, associated with the greatest saliency. Search times for the green background were around 150 ms longer than for the white. Desaturated colors, along with those close to a typical CDNVG display phosphor in color space, should be avoided by CDNVG designers if the greatest conspicuity of symbology is desired. The results can be used by CDNVG symbology designers to optimize aircrew performance subject to wider constraints arising from the way color is used in the existing conventional cockpit instruments and displays.Liggins EP, Serle WP. Color vision in color display night vision goggles. Aerosp Med Hum Perform. 2017; 88(5):448-456.

  10. Real Time Target Tracking Using Dedicated Vision Hardware

    NASA Astrophysics Data System (ADS)

    Kambies, Keith; Walsh, Peter

    1988-03-01

    This paper describes a real-time vision target tracking system developed by Adaptive Automation, Inc. and delivered to NASA's Launch Equipment Test Facility, Kennedy Space Center, Florida. The target tracking system is part of the Robotic Application Development Laboratory (RADL) which was designed to provide NASA with a general purpose robotic research and development test bed for the integration of robot and sensor systems. One of the first RADL system applications is the closing of a position control loop around a six-axis articulated arm industrial robot using a camera and dedicated vision processor as the input sensor so that the robot can locate and track a moving target. The vision system is inside of the loop closure of the robot tracking system, therefore, tight throughput and latency constraints are imposed on the vision system that can only be met with specialized hardware and a concurrent approach to the processing algorithms. State of the art VME based vision boards capable of processing the image at frame rates were used with a real-time, multi-tasking operating system to achieve the performance required. This paper describes the high speed vision based tracking task, the system throughput requirements, the use of dedicated vision hardware architecture, and the implementation design details. Important to the overall philosophy of the complete system was the hierarchical and modular approach applied to all aspects of the system, hardware and software alike, so there is special emphasis placed on this topic in the paper.

  11. Flicker Vision of Selected Light Sources

    NASA Astrophysics Data System (ADS)

    Otomański, Przemysław; Wiczyński, Grzegorz; Zając, Bartosz

    2017-10-01

    The results of the laboratory research concerning a dependence of flicker vision on voltage fluctuations are presented in the paper. The research was realized on a designed measuring stand, which included an examined light source, a voltage generator with amplitude modulation supplying the light source and a positioning system of the observer with respect to the observed surface. In this research, the following light sources were used: one incandescent lamp and four LED luminaires by different producers. The research results formulate a conclusion concerning the description of the influence of voltage fluctuations on flicker viewing for selected light sources. The research results indicate that LED luminaires are less susceptible to voltage fluctuations than incandescent bulbs and that flicker vision strongly depends on the type of LED source.

  12. Stereo vision for ecohydraulic research: Seashell reconstruction

    NASA Astrophysics Data System (ADS)

    Friedrich, H.; Bertin, S.; Montgomery, J. C.; Thrush, S. F.; Delmas, P.

    2016-12-01

    3D information of underwater topographies can be obtained more easily nowadays. In general, those measurements do not provide the spatial nor temporal detail for more specific research of dynamic processes, such as sediment transport. More recently, we have seen the advance of true interdisciplinary ecohydraulics research initiatives. One important research avenue is the interaction of organisms with flow and sediment. We have used stereo vision substantially for fluvial morphology studies over the last years, and will present and discuss the use of stereo vision in ecohydraulic research. The work is undertaken in the laboratory, and we present a workflow of reconstructing seashells. We obtain shape and dimensional information, which are important to better understand the organism's interaction in the natural water environment. Although we find that stereo vision is suitable to capture our studied organisms, the challenge of studying organisms in their natural environments persists. We discuss the limitations of our approach, and the need to fuse technical and behavioural knowledge to better manage our ecosystems.

  13. [Comparison study between biological vision and computer vision].

    PubMed

    Liu, W; Yuan, X G; Yang, C X; Liu, Z Q; Wang, R

    2001-08-01

    The development and bearing of biology vision in structure and mechanism were discussed, especially on the aspects including anatomical structure of biological vision, tentative classification of reception field, parallel processing of visual information, feedback and conformity effect of visual cortical, and so on. The new advance in the field was introduced through the study of the morphology of biological vision. Besides, comparison between biological vision and computer vision was made, and their similarities and differences were pointed out.

  14. Oak Ridge National Laboratory Institutional Plan, FY 1995--FY 2000

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-11-01

    This report discusses the institutional plan for Oak Ridge National Laboratory for the next five years (1995-2000). Included in this report are the: laboratory director`s statement; laboratory mission, vision, and core competencies; laboratory plan; major laboratory initiatives; scientific and technical programs; critical success factors; summaries of other plans; and resource projections.

  15. Ideas for Teaching Vision and Visioning

    ERIC Educational Resources Information Center

    Quijada, Maria Alejandra

    2017-01-01

    In teaching leadership, a key element to include should be a discussion about vision: what it is, how to communicate it, and how to ensure that it is effective and shared. This article describes a series of exercises that rely on videos to illustrate different aspects of vision and visioning, both in the positive and in the negative. The article…

  16. BROOKHAVEN NATIONAL LABORATORY INSTITUTIONAL PLAN FY2003-2007.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    This document presents the vision for Brookhaven National Laboratory (BNL) for the next five years, and a roadmap for implementing that vision. Brookhaven is a multidisciplinary science-based laboratory operated for the U.S. Department of Energy (DOE), supported primarily by programs sponsored by the DOE's Office of Science. As the third-largest funding agency for science in the U.S., one of the DOE's goals is ''to advance basic research and the instruments of science that are the foundations for DOE's applied missions, a base for U.S. technology innovation, and a source of remarkable insights into our physical and biological world, and themore » nature of matter and energy'' (DOE Office of Science Strategic Plan, 2000 http://www.osti.gov/portfolio/science.htm). BNL shapes its vision according to this plan.« less

  17. Benchmarking neuromorphic vision: lessons learnt from computer vision

    PubMed Central

    Tan, Cheston; Lallee, Stephane; Orchard, Garrick

    2015-01-01

    Neuromorphic Vision sensors have improved greatly since the first silicon retina was presented almost three decades ago. They have recently matured to the point where they are commercially available and can be operated by laymen. However, despite improved availability of sensors, there remains a lack of good datasets, while algorithms for processing spike-based visual data are still in their infancy. On the other hand, frame-based computer vision algorithms are far more mature, thanks in part to widely accepted datasets which allow direct comparison between algorithms and encourage competition. We are presented with a unique opportunity to shape the development of Neuromorphic Vision benchmarks and challenges by leveraging what has been learnt from the use of datasets in frame-based computer vision. Taking advantage of this opportunity, in this paper we review the role that benchmarks and challenges have played in the advancement of frame-based computer vision, and suggest guidelines for the creation of Neuromorphic Vision benchmarks and challenges. We also discuss the unique challenges faced when benchmarking Neuromorphic Vision algorithms, particularly when attempting to provide direct comparison with frame-based computer vision. PMID:26528120

  18. DESALINATION AND WATER TREATMENT RESEARCH AT SANDIA NATIONAL LABORATORIES.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rigali, Mark J.; Miller, James E.; Altman, Susan J.

    Water is the backbone of our economy - safe and adequate supplies of water are vital for agriculture, industry, recreation, and human consumption. While our supply of water today is largely safe and adequate, we as a nation face increasing water supply challenges in the form of extended droughts, demand growth due to population increase, more stringent health-based regulation, and competing demands from a variety of users. To meet these challenges in the coming decades, water treatment technologies, including desalination, will contribute substantially to ensuring a safe, sustainable, affordable, and adequate water supply for the United States. This overview documentsmore » Sandia National Laboratories' (SNL, or Sandia) Water Treatment Program which focused on the development and demonstration of advanced water purification technologies as part of the larger Sandia Water Initiative. Projects under the Water Treatment Program include: (1) the development of desalination research roadmaps (2) our efforts to accelerate the commercialization of new desalination and water treatment technologies (known as the 'Jump-Start Program),' (3) long range (high risk, early stage) desalination research (known as the 'Long Range Research Program'), (4) treatment research projects under the Joint Water Reuse & Desalination Task Force, (5) the Arsenic Water Technology Partnership Program, (6) water treatment projects funded under the New Mexico Small Business Administration, (7) water treatment projects for the National Energy Technology Laboratory (NETL) and the National Renewable Energy Laboratory (NREL), (8) Sandia- developed contaminant-selective treatment technologies, and finally (9) current Laboratory Directed Research and Development (LDRD) funded desalination projects.« less

  19. Disparity channels in early vision

    PubMed Central

    Roe, AW; Parker, AJ; Born, RT; DeAngelis, GC

    2008-01-01

    The last decade has seen a dramatic increase in our knowledge of the neural basis of stereopsis. New cortical areas have been found to represent binocular disparities, new representations of disparity information (e.g., relative disparity signals) have been uncovered, the first topographic maps of disparity have been measured, and the first causal links between neural activity and depth perception have been established. Equally exciting is the finding that training and experience affects how signals are channeled through different brain areas, a flexibility that may be crucial for learning, plasticity, and recovery of function. The collective efforts of several laboratories have established stereo vision as one of the most productive model systems for elucidating the neural basis of perception. Much remains to be learned about how the disparity signals that are initially encoded in primary visual cortex are routed to and processed by extrastriate areas to mediate the diverse capacities of 3D vision that enhance our daily experience of the world. PMID:17978018

  20. Quality and future of clinical laboratories: the Vico's whole cyclical theory of the recurring cycles.

    PubMed

    Plebani, Mario

    2018-05-24

    In the last few decades, laboratory medicine has undergone monumental changes, and laboratory technology, which has made enormous advances, now has new clinical applications thanks to the identification of a growing number of biomarkers and risk factors conducive to the promotion of predictive and preventive interventions that have enhanced the role of laboratory medicine in health care delivering. However, the paradigm shift in the past 50 years has led to a gap between laboratory and clinic, with an increased risk of inappropriateness in test request and interpretation, as well as the consolidation of analytical work in focused factories and megastructurers oriented only toward achieving greater volumes, decreasing cost per test and generating a vision of laboratory services as simple commodities. A careful historical revision of the changing models for delivering laboratory services in the United States leads to the prediction that there are several reasons for counteracting the vision of clinical laboratory as a commodity, and restoring the true nature of laboratory services as an integral part of the diagnosis and therapy process. The present study, which reports on internal and external drivers for change, proposes an integrated vision of quality in laboratory medicine.

  1. Wearable Improved Vision System for Color Vision Deficiency Correction

    PubMed Central

    Riccio, Daniel; Di Perna, Luigi; Sanniti Di Baja, Gabriella; De Nino, Maurizio; Rossi, Settimio; Testa, Francesco; Simonelli, Francesca; Frucci, Maria

    2017-01-01

    Color vision deficiency (CVD) is an extremely frequent vision impairment that compromises the ability to recognize colors. In order to improve color vision in a subject with CVD, we designed and developed a wearable improved vision system based on an augmented reality device. The system was validated in a clinical pilot study on 24 subjects with CVD (18 males and 6 females, aged 37.4 ± 14.2 years). The primary outcome was the improvement in the Ishihara Vision Test score with the correction proposed by our system. The Ishihara test score significantly improved (\\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{upgreek} \\usepackage{mathrsfs} \\setlength{\\oddsidemargin}{-69pt} \\begin{document} }{}$p = 0.03$ \\end{document}) from 5.8 ± 3.0 without correction to 14.8 ± 5.0 with correction. Almost all patients showed an improvement in color vision, as shown by the increased test scores. Moreover, with our system, 12 subjects (50%) passed the vision color test as normal vision subjects. The development and preliminary validation of the proposed platform confirm that a wearable augmented-reality device could be an effective aid to improve color vision in subjects with CVD. PMID:28507827

  2. Teacher Training Workshop for Educators of Students Who Are Blind or Low Vision

    ERIC Educational Resources Information Center

    Supalo, Cary A.; Dwyer, Danielle; Eberhart, Heather L.; Bunnag, Natasha; Mallouk, Thomas E.

    2009-01-01

    The Independent Laboratory Access for the Blind (ILAB) project has developed a suite of speech accessible tools for students who are blind or low vision to use in secondary and postsecondary science laboratory classes. The following are illustrations of experiments designed to be used by educators to introduce them to the ILAB tools, and to…

  3. Establishing a shared vision in your organization. Winning strategies to empower your team members.

    PubMed

    Rinke, W J

    1989-01-01

    Today's health-care climate demands that you manage your human resources more effectively. Meeting the dual challenges of providing more with less requires that you tap the vast hidden resources that reside in every one of your team members. Harnessing these untapped energies requires that all of your employees clearly understand the purpose, direction, and the desired future state of your laboratory. Once this image is widely shared, your team members will know their roles in the organization and the contributions they can make to attaining the organization's vision. This shared vision empowers people and enhances their self-esteem as they recognize they are accomplishing a worthy goal. You can create and install a shared vision in your laboratory by adhering to a five-step process. The result will be a unity of purpose that will release the untapped human resources in your organization so that you can do more with less.

  4. Teaching chemistry and other sciences to blind and low-vision students through hands-on learning experiences in high school science laboratories

    NASA Astrophysics Data System (ADS)

    Supalo, Cary Alan

    2010-11-01

    Students with blindness and low vision (BLV) have traditionally been underrepresented in the sciences as a result of technological and attitudinal barriers to equal access in science laboratory classrooms. The Independent Laboratory Access for the Blind (ILAB) project developed and evaluated a suite of talking and audible hardware/software tools to empower students with BLV to have multisensory, hands-on laboratory learning experiences. This dissertation focuses on the first year of ILAB tool testing in mainstream science laboratory classrooms, and comprises a detailed multi-case study of four students with BLV who were enrolled in high school science classes during 2007--08 alongside sighted students. Participants attended different schools; curricula included chemistry, AP chemistry, and AP physics. The ILAB tools were designed to provide multisensory means for students with BLV to make observations and collect data during standard laboratory lessons on an equivalent basis with their sighted peers. Various qualitative and quantitative data collection instruments were used to determine whether the hands-on experiences facilitated by the ILAB tools had led to increased involvement in laboratory-goal-directed actions, greater peer acceptance in the students' lab groups, improved attitudes toward science, and increased interest in science. Premier among the ILAB tools was the JAWS/Logger Pro software interface, which made audible all information gathered through standard Vernier laboratory probes and visually displayed through Logger Pro. ILAB tools also included a talking balance, a submersible audible light sensor, a scientific talking stopwatch, and a variety of other high-tech and low-tech devices and techniques. While results were mixed, all four participating BLV students seemed to have experienced at least some benefit, with the effect being stronger for some than for others. Not all of the data collection instruments were found to reveal improvements for all

  5. 3D vision upgrade kit for the TALON robot system

    NASA Astrophysics Data System (ADS)

    Bodenhamer, Andrew; Pettijohn, Bradley; Pezzaniti, J. Larry; Edmondson, Richard; Vaden, Justin; Hyatt, Brian; Morris, James; Chenault, David; Tchon, Joe; Barnidge, Tracy; Kaufman, Seth; Kingston, David; Newell, Scott

    2010-02-01

    In September 2009 the Fort Leonard Wood Field Element of the US Army Research Laboratory - Human Research and Engineering Directorate, in conjunction with Polaris Sensor Technologies and Concurrent Technologies Corporation, evaluated the objective performance benefits of Polaris' 3D vision upgrade kit for the TALON small unmanned ground vehicle (SUGV). This upgrade kit is a field-upgradable set of two stereo-cameras and a flat panel display, using only standard hardware, data and electrical connections existing on the TALON robot. Using both the 3D vision system and a standard 2D camera and display, ten active-duty Army Soldiers completed seven scenarios designed to be representative of missions performed by military SUGV operators. Mission time savings (6.5% to 32%) were found for six of the seven scenarios when using the 3D vision system. Operators were not only able to complete tasks quicker but, for six of seven scenarios, made fewer mistakes in their task execution. Subjective Soldier feedback was overwhelmingly in support of pursuing 3D vision systems, such as the one evaluated, for fielding to combat units.

  6. Grounding Our Vision: Brain Research and Strategic Vision

    ERIC Educational Resources Information Center

    Walker, Mike

    2011-01-01

    While recognizing the value of "vision," it could be argued that vision alone--at least in schools--is not enough to rally the financial and emotional support required to translate an idea into reality. A compelling vision needs to reflect substantive, research-based knowledge if it is to spark the kind of strategic thinking and insight…

  7. SUBTASK 6.1 – STRATEGIC STUDIES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erickson, Thomas; Harju, John; Steadman, Edward

    The Energy & Environmental Research Center (EERC) has recently completed 7 years of research through the Cooperative Agreement with the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL) focused on fossil energy technology development and demonstration. To support a significant number of the different activities being considered within all of our research contracts with NETL, a subtask (6.1 – Strategic Studies) was created to focus on small research efforts that came up throughout the year that would support an existing EERC–NETL project or would help to develop a new concept for inclusion in future efforts. This subtask wasmore » funded through the EERC–DOE Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FC26- 08NT43291« less

  8. Subtask 7.1 - Strategic Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas Erickson

    2009-03-30

    The Energy & Environmental Research Center (EERC) has recently completed 11 years of research through the Cooperative Agreement with the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL) focused on fossil energy technology development and demonstration. To support a significant number of the different activities being considered within all of our research contracts with NETL, a subtask (7.1 Strategic Studies) was created to focus on small research efforts that came up throughout the year which would support an existing EERC-NETL project or would help to develop a new concept for inclusion in future efforts. Typical efforts conducted undermore » this task were usually between $15,000 and $60,000 in scope and had time lines of less than 6 months. A limited number of larger studies were also conducted, generally at the direct request of NETL. Over the life of this task, 46 projects were conducted. These efforts ranged from quick experiments to gain fundamental knowledge to support a current effort, to literature reviews, to a few larger engineering efforts.« less

  9. Night vision and electro-optics technology transfer, 1972 - 1981

    NASA Astrophysics Data System (ADS)

    Fulton, R. W.; Mason, G. F.

    1981-09-01

    The purpose of this special report, 'Night Vision and Electro-Optics Technology Transfer 1972-1981,' is threefold: To illustrate, through actual case histories, the potential for exploiting a highly developed and available military technology for solving non-military problems. To provide, in a layman's language, the principles behind night vision and electro-optical devices in order that an awareness may be developed relative to the potential for adopting this technology for non-military applications. To obtain maximum dollar return from research and development investments by applying this technology to secondary applications. This includes, but is not limited to, applications by other Government agencies, state and local governments, colleges and universities, and medical organizations. It is desired that this summary of Technology Transfer activities within Night Vision and Electro-Optics Laboratory (NV/EOL) will benefit those who desire to explore one of the vast technological resources available within the Defense Department and the Federal Government.

  10. Cyclic stability testing of aminated-silica solid sorbent for post-combustion CO2 capture.

    PubMed

    Fisher, James C; Gray, McMahan

    2015-02-01

    The National Energy Technology Laboratory (NETL) is examining the use of solid sorbents for CO2 removal from coal-fired power plant flue gas streams. An aminated sorbent (previously reported by the NETL) is tested for stability by cyclic exposure to simulated flue gas and subsequent regeneration for 100 cycles. Each cycle was quantified using a traced gas in the simulated flue gas monitored by a mass spectrometer, which allowed for rapid determination of the capacity. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Making a vision document tangible using "vision-tactics-metrics" tables.

    PubMed

    Drury, Ivo; Slomski, Carol

    2006-01-01

    We describe a method of making a vision document tangible by attaching specific tactics and metrics to the key elements of the vision. We report on the development and early use of a "vision-tactics-metrics" table in a department of surgery. Use of the table centered the vision in the daily life of the department and its faculty, and facilitated cultural change.

  12. Abstract - Cooperative Research and Development Agreement between Environmental Defense Fund and National Energy Technology Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rose, Kelly K.; Zavala-Zraiza, Daniel

    Here, we summarize an effort to develop a global oil and gas infrastructure (GOGI) taxonomy and geodatabase, using a combination of big data computing, custom search and data integration algorithms, and expert driven spatio-temporal analytics to identify, access, and evaluate open oil and gas data resources and uncertainty trends worldwide. This approach leveraged custom National Energy Technology Laboratory (NETL) tools and capabilities in collaboration with Environmental Defense Fund (EDF) and Carbon Limits subject matter expertise, to identify over 380 datasets and integrate more than 4.8 million features into the GOGI database. In addition to acquisition of open oil and gasmore » infrastructure data, information was collected and analyzed to assess the spatial, temporal, and source quality of these resources, and estimate their completeness relative to the top 40 hydrocarbon producing and consuming countries.« less

  13. Influence of Socially Used Drugs on Vision and Vision Performance

    DTIC Science & Technology

    1974-07-31

    AD-A012 909 INFLUENCE OF SOCIALLY USED DRUGS ON VISION AND VISION PERFORMANCE OPTICAL SCIENCES GROUP PREPARED FOR ARMY MEDICAL RESEARCH AND...AND ADDRESS 12. REPORT DATE July 11, 1974 U.S. Army Medical Research and D mvelopmenteommand 13. NUMBER OF PAGES Washington, D.C. 203114 14...nreeeoary and identily by block number) vision vision performance alcohol marijuana tetrahydrocannabinol 20. ABSTRACT (Continue on reverae aide It

  14. Evaluation of visual acuity with Gen 3 night vision goggles

    NASA Technical Reports Server (NTRS)

    Bradley, Arthur; Kaiser, Mary K.

    1994-01-01

    Using laboratory simulations, visual performance was measured at luminance and night vision imaging system (NVIS) radiance levels typically encountered in the natural nocturnal environment. Comparisons were made between visual performance with unaided vision and that observed with subjects using image intensification. An Amplified Night Vision Imaging System (ANVIS6) binocular image intensifier was used. Light levels available in the experiments (using video display technology and filters) were matched to those of reflecting objects illuminated by representative night-sky conditions (e.g., full moon, starlight). Results show that as expected, the precipitous decline in foveal acuity experienced with decreasing mesopic luminance levels is effectively shifted to much lower light levels by use of an image intensification system. The benefits of intensification are most pronounced foveally, but still observable at 20 deg eccentricity. Binocularity provides a small improvement in visual acuity under both intensified and unintensified conditions.

  15. Understanding of and applications for robot vision guidance at KSC

    NASA Technical Reports Server (NTRS)

    Shawaga, Lawrence M.

    1988-01-01

    The primary thrust of robotics at KSC is for the servicing of Space Shuttle remote umbilical docking functions. In order for this to occur, robots performing servicing operations must be capable of tracking a swaying Orbiter in Six Degrees of Freedom (6-DOF). Currently, in NASA KSC's Robotic Applications Development Laboratory (RADL), an ASEA IRB-90 industrial robot is being equipped with a real-time computer vision (hardware and software) system to allow it to track a simulated Orbiter interface (target) in 6-DOF. The real-time computer vision system effectively becomes the eyes for the lab robot, guiding it through a closed loop visual feedback system to move with the simulated Orbiter interface. This paper will address an understanding of this vision guidance system and how it will be applied to remote umbilical servicing at KSC. In addition, other current and future applications will be addressed.

  16. Colour vision deficiency.

    PubMed

    Simunovic, M P

    2010-05-01

    Colour vision deficiency is one of the commonest disorders of vision and can be divided into congenital and acquired forms. Congenital colour vision deficiency affects as many as 8% of males and 0.5% of females--the difference in prevalence reflects the fact that the commonest forms of congenital colour vision deficiency are inherited in an X-linked recessive manner. Until relatively recently, our understanding of the pathophysiological basis of colour vision deficiency largely rested on behavioural data; however, modern molecular genetic techniques have helped to elucidate its mechanisms. The current management of congenital colour vision deficiency lies chiefly in appropriate counselling (including career counselling). Although visual aids may be of benefit to those with colour vision deficiency when performing certain tasks, the evidence suggests that they do not enable wearers to obtain normal colour discrimination. In the future, gene therapy remains a possibility, with animal models demonstrating amelioration following treatment.

  17. Pittsburgh 2013 Energy Baseline: Consumption, Trends & Opportunities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tarka, Thomas J.; James III, Robert E.; Withum, Jeffrey A.

    2017-03-01

    The United States (U.S.) Department of Energy (DOE) and the National Energy Technology Laboratory (NETL) are working in conjunction with the City of Pittsburgh (City) to transform how energy is produced, transported, and consumed in the City. This transformation will rely on 21st Century Energy Infrastructure designs, which leverage advanced technology and design techniques to modernize energy infrastructure, create new business models and markets, and expand technology research and development opportunities. Achieving this vision will require developing solutions that are unique to the City: its climate, topography, energy needs, resources, and existing infrastructure.a In this way, the City will demonstratemore » what the American “City of the Future” looks like, with all its attendant environmental, economic, and job-creation benefits. It will also serve as a template for other cities seeking to reinvent their energy systems.« less

  18. Air Force Research Laboratory’s Focused Long Term Challenges

    DTIC Science & Technology

    2008-04-01

    Air Force Research Laboratory ( AFRL ) mission is to provide support to the Air Force (AF) and the warfighters with... Air Force Research Laboratory’s Focused Long Term Challenges Leo J Rose Munitions Directorate, Air Force Research Laboratory , 101 W Eglin Blvd...This technology vision, which was born in our Air Force Research Laboratory , builds on the Air Force’s traditional kill

  19. AN INVESTIGATION OF VISION PROBLEMS AND THE VISION CARE SYSTEM IN RURAL CHINA.

    PubMed

    Bai, Yunli; Yi, Hongmei; Zhang, Linxiu; Shi, Yaojiang; Ma, Xiaochen; Congdon, Nathan; Zhou, Zhongqiang; Boswell, Matthew; Rozelle, Scott

    2014-11-01

    This paper examines the prevalence of vision problems and the accessibility to and quality of vision care in rural China. We obtained data from 4 sources: 1) the National Rural Vision Care Survey; 2) the Private Optometrists Survey; 3) the County Hospital Eye Care Survey; and 4) the Rural School Vision Care Survey. The data from each of the surveys were collected by the authors during 2012. Thirty-three percent of the rural population surveyed self-reported vision problems. Twenty-two percent of subjects surveyed had ever had a vision exam. Among those who self-reported having vision problems, 34% did not wear eyeglasses. Fifty-four percent of those with vision problems who had eyeglasses did not have a vision exam prior to receiving glasses. However, having a vision exam did not always guarantee access to quality vision care. Four channels of vision care service were assessed. The school vision examination program did not increase the usage rate of eyeglasses. Each county-hospital was staffed with three eye-doctors having one year of education beyond high school, serving more than 400,000 residents. Private optometrists often had low levels of education and professional certification. In conclusion, our findings shows that the vision care system in rural China is inadequate and ineffective in meeting the needs of the rural population sampled.

  20. The Laboratory for Terrestrial Physics

    NASA Technical Reports Server (NTRS)

    2003-01-01

    The Laboratory for Terrestrial Physics is dedicated to the advancement of knowledge in Earth and planetary science, by conducting innovative research using space technology. The Laboratory's mission and activities support the work and new initiatives at NASA's Goddard Space Flight Center (GSFC). The Laboratory's success contributes to the Earth Science Directorate as a national resource for studies of Earth from Space. The Laboratory is part of the Earth Science Directorate based at the GSFC in Greenbelt, MD. The Directorate itself is comprised of the Global Change Data Center (GCDC), the Space Data and Computing Division (SDCD), and four science Laboratories, including Laboratory for Terrestrial Physics, Laboratory for Atmospheres, and Laboratory for Hydrospheric Processes all in Greenbelt, MD. The fourth research organization, Goddard Institute for Space Studies (GISS), is in New York, NY. Relevant to NASA's Strategic Plan, the Laboratory ensures that all work undertaken and completed is within the vision of GSFC. The philosophy of the Laboratory is to balance the completion of near term goals, while building on the Laboratory's achievements as a foundation for the scientific challenges in the future.

  1. Light and the laboratory mouse.

    PubMed

    Peirson, Stuart N; Brown, Laurence A; Pothecary, Carina A; Benson, Lindsay A; Fisk, Angus S

    2018-04-15

    Light exerts widespread effects on physiology and behaviour. As well as the widely-appreciated role of light in vision, light also plays a critical role in many non-visual responses, including regulating circadian rhythms, sleep, pupil constriction, heart rate, hormone release and learning and memory. In mammals, responses to light are all mediated via retinal photoreceptors, including the classical rods and cones involved in vision as well as the recently identified melanopsin-expressing photoreceptive retinal ganglion cells (pRGCs). Understanding the effects of light on the laboratory mouse therefore depends upon an appreciation of the physiology of these retinal photoreceptors, including their differing sens itivities to absolute light levels and wavelengths. The signals from these photoreceptors are often integrated, with different responses involving distinct retinal projections, making generalisations challenging. Furthermore, many commonly used laboratory mouse strains carry mutations that affect visual or non-visual physiology, ranging from inherited retinal degeneration to genetic differences in sleep and circadian rhythms. Here we provide an overview of the visual and non-visual systems before discussing practical considerations for the use of light for researchers and animal facility staff working with laboratory mice. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  2. An Rx for 20/20 Vision: Vision Planning and Education.

    ERIC Educational Resources Information Center

    Chrisman, Gerald J.; Holliday, Clifford R.

    1996-01-01

    Discusses the Dallas Independent School District's decision to adopt an integrated technology infrastructure and the importance of vision planning for long term goals. Outlines the vision planning process: first draft; environmental projection; restatement of vision in terms of market projections, anticipated customer needs, suspected competitor…

  3. Vision Therapy News Backgrounder.

    ERIC Educational Resources Information Center

    American Optometric Association, St. Louis, MO.

    The booklet provides an overview on vision therapy to aid writers, editors, and broadcasters help parents, teachers, older adults, and all consumers learn more about vision therapy. Following a description of vision therapy or vision training, information is provided on how and why vision therapy works. Additional sections address providers of…

  4. Vision and art: an interdisciplinary approach to neuroscience education.

    PubMed

    Lafer-Sousa, Rosa; Conway, Bevil R

    2009-01-01

    Undergraduate institutions are increasingly adopting neuroscience within their curricula, although it is unclear how best to implement this material given the interdisciplinary nature of the field, which requires knowledge of basic physics, chemistry, biology and psychology. This difficulty is compounded by declines over recent decades in the amount of physics education that students receive in high school, which hinders students' ability to grasp basic principles of neuroscience. Here we discuss our experiences as teacher (BRC) and student (RLS) with an undergraduate course in Vision and Art. The course capitalizes on students' prior interest in visual art to motivate an understanding of the physiological and computational neural processes that underlie vision; our aim is that the learning strategies that students acquire as a result of the format and interdisciplinary approach of the course will increase students' critical thinking skills and benefit them as they pursue other domains of inquiry. The course includes both expert lectures on central themes of vision along with a problem-based learning (PBL) laboratory component that directly engages the students as empirical scientists. We outline the syllabus, the motivation for using PBL, and describe a number of hands-on laboratory exercises, many of which require only inexpensive and readily available equipment. We have developed a website that we hope will facilitate student-driven inquiry beyond the classroom and foster inter-institutional collaboration in this endeavor. We conclude the paper with a discussion of the potential limitations of the course and how to evaluate the success of the course and the website.

  5. Color vision test

    MedlinePlus

    ... present from birth) color vision problems: Achromatopsia -- complete color blindness , seeing only shades of gray Deuteranopia -- difficulty telling ... Vision test - color; Ishihara color vision test Images Color blindness tests References Bowling B. Hereditary fundus dystrophies. In: ...

  6. Ultraviolet-Blocking Lenses Protect, Enhance Vision

    NASA Technical Reports Server (NTRS)

    2010-01-01

    To combat the harmful properties of light in space, as well as that of artificial radiation produced during laser and welding work, Jet Propulsion Laboratory (JPL) scientists developed a lens capable of absorbing, filtering, and scattering the dangerous light while not obstructing vision. SunTiger Inc. now Eagle Eyes Optics, of Calabasas, California was formed to market a full line of sunglasses based on the JPL discovery that promised 100-percent elimination of harmful wavelengths and enhanced visual clarity. The technology was recently inducted into the Space Technology Hall of Fame.

  7. Nanoscience and Technology at the Air Force Research Laboratory (AFRL)

    DTIC Science & Technology

    2005-05-01

    AIR FORCE RESEARCH LABORATORY ( AFRL ) Dr. Richard A. Vaia Dr. Daniel Miracle Dr. Thomas Cruse Air Force Research ...Technology At The Air Force Research Laboratory ( AFRL ) 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT...98) Prescribed by ANSI Std Z39-18 AFRL NST Overview 2 AIR FORCE RESEARCH LABORATORY VISION We defend

  8. Nanoscience and Technology at the Air Force Research Laboratory (AFRL)

    DTIC Science & Technology

    2005-02-01

    AIR FORCE RESEARCH LABORATORY ( AFRL ) Dr. Richard A. Vaia Dr. Daniel Miracle Dr. Thomas Cruse Air Force Research ...Technology At The Air Force Research Laboratory ( AFRL ) 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT...98) Prescribed by ANSI Std Z39-18 AFRL NST Overview 2 AIR FORCE RESEARCH LABORATORY VISION We defend

  9. Computer vision challenges and technologies for agile manufacturing

    NASA Astrophysics Data System (ADS)

    Molley, Perry A.

    1996-02-01

    Sandia National Laboratories, a Department of Energy laboratory, is responsible for maintaining the safety, security, reliability, and availability of the nuclear weapons stockpile for the United States. Because of the changing national and global political climates and inevitable budget cuts, Sandia is changing the methods and processes it has traditionally used in the product realization cycle for weapon components. Because of the increasing age of the nuclear stockpile, it is certain that the reliability of these weapons will degrade with time unless eventual action is taken to repair, requalify, or renew them. Furthermore, due to the downsizing of the DOE weapons production sites and loss of technical personnel, the new product realization process is being focused on developing and deploying advanced automation technologies in order to maintain the capability for producing new components. The goal of Sandia's technology development program is to create a product realization environment that is cost effective, has improved quality and reduced cycle time for small lot sizes. The new environment will rely less on the expertise of humans and more on intelligent systems and automation to perform the production processes. The systems will be robust in order to provide maximum flexibility and responsiveness for rapidly changing component or product mixes. An integrated enterprise will allow ready access to and use of information for effective and efficient product and process design. Concurrent engineering methods will allow a speedup of the product realization cycle, reduce costs, and dramatically lessen the dependency on creating and testing physical prototypes. Virtual manufacturing will allow production processes to be designed, integrated, and programed off-line before a piece of hardware ever moves. The overriding goal is to be able to build a large variety of new weapons parts on short notice. Many of these technologies that are being developed are also

  10. Blindness and vision loss

    MedlinePlus

    ... eye ( chemical burns or sports injuries) Diabetes Glaucoma Macular degeneration The type of partial vision loss may differ, ... tunnel vision and missing areas of vision With macular degeneration, the side vision is normal but the central ...

  11. Robot Vision Library

    NASA Technical Reports Server (NTRS)

    Howard, Andrew B.; Ansar, Adnan I.; Litwin, Todd E.; Goldberg, Steven B.

    2009-01-01

    The JPL Robot Vision Library (JPLV) provides real-time robot vision algorithms for developers who are not vision specialists. The package includes algorithms for stereo ranging, visual odometry and unsurveyed camera calibration, and has unique support for very wideangle lenses

  12. Vision impairment and major causes of vision loss impacts on vision-specific functioning independent of socioeconomic factors.

    PubMed

    Chiang, Peggy P C; Zheng, Yingfeng; Wong, Tien Y; Lamoureux, Ecosse L

    2013-02-01

    To quantify the eye disease-specific impact of unilateral and bilateral vision impairment (VI) on vision-specific functioning (VF). The Singapore Indian Eye population-based study. Ethnic Indians older than 40 years of age living in Singapore. Participants underwent standardized ophthalmic assessments for VI and blindness, defined using presenting visual acuity (United States definition). Sociodemographic data were recorded using a standardized questionnaire. Rasch analysis was used to validate the Visual Function Index 11 and to determine its psychometric properties. The major causes of VI (i.e., cataract, refractive error, age-related macular degeneration, diabetic retinopathy [DR], and glaucoma) were determined by ophthalmologists on examination. Multivariate linear regression analysis was performed to assess the impact of VI on the overall VF Rasch score. Vision-specific functioning. Three thousand three hundred ninety-six persons were analyzed. Participants with VI had a systematic reduction in VF score compared with those with normal vision in both eyes, ranging from -11.2% normal vision in one eye and low vision in the other eye (95% confidence interval [CI], -12.2% to -10.3%; P<0.001), to -12.7% blindness in one eye and normal vision in the other eye (CI, -15.1% to -10.4%; P<0.001), to -19.4% low vision in both eyes (CI, -20.8% to -18.1%; P<0.001), to -52.9% blindness in one eye and low vision in other eye (CI, -55.3% to -50.4%; P<0.001), to -77.2% blindness in both eyes (CI, -82.4% to 72.0%; P<0.001). The impact of VI on VF score varied across different major causes of vision loss, regardless of socioeconomic factors. Vision impairment attributed to cataract in one or both eyes had a significant decrease in VF score by 17.7% and 22.3%, respectively, compared with those with normal vision in both eyes (P<0.001). The impact of unilateral and bilateral VI on VF score was greater in participants with glaucoma (32.2% in unilateral cases and 35.9% in bilateral

  13. Wind Vision: A New Era for Wind Power in the United States

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    U.S. Department of Energy

    With more than 4.5% of the nation's electricity supplied by wind energy today, the Department of Energy has collaborated with industry, environmental organizations, academic institutions, and national laboratories to develop a renewed Wind Vision, documenting the contributions of wind to date and envisioning a future where wind continues to provide key contributions to the nation’s energy portfolio. Building on and updating the 2008 20% Wind Energy by 2030 report, the new Wind Vision Report quantifies the economic, environmental, and social benefits of a robust wind energy future and the actions that wind stakeholders can take to make it a reality.

  14. How to assess vision.

    PubMed

    Marsden, Janet

    2016-09-21

    Rationale and key points An objective assessment of the patient's vision is important to assess variation from 'normal' vision in acute and community settings, to establish a baseline before examination and treatment in the emergency department, and to assess any changes during ophthalmic outpatient appointments. » Vision is one of the essential senses that permits people to make sense of the world. » Visual assessment does not only involve measuring central visual acuity, it also involves assessing the consequences of reduced vision. » Assessment of vision in children is crucial to identify issues that might affect vision and visual development, and to optimise lifelong vision. » Untreatable loss of vision is not an inevitable consequence of ageing. » Timely and repeated assessment of vision over life can reduce the incidence of falls, prevent injury and optimise independence. Reflective activity 'How to' articles can help update you practice and ensure it remains evidence based. Apply this article to your practice. Reflect on and write a short account of: 1. How this article might change your practice when assessing people holistically. 2. How you could use this article to educate your colleagues in the assessment of vision.

  15. Improving Vision

    NASA Technical Reports Server (NTRS)

    2003-01-01

    Many people are familiar with the popular science fiction series Star Trek: The Next Generation, a show featuring a blind character named Geordi La Forge, whose visor-like glasses enable him to see. What many people do not know is that a product very similar to Geordi's glasses is available to assist people with vision conditions, and a NASA engineer's expertise contributed to its development. The JORDY(trademark) (Joint Optical Reflective Display) device, designed and manufactured by a privately-held medical device company known as Enhanced Vision, enables people with low vision to read, write, and watch television. Low vision, which includes macular degeneration, diabetic retinopathy, and glaucoma, describes eyesight that is 20/70 or worse, and cannot be fully corrected with conventional glasses.

  16. Mathematical leadership vision.

    PubMed

    Hamburger, Y A

    2000-11-01

    This article is an analysis of a new type of leadership vision, the kind of vision that is becoming increasingly pervasive among leaders in the modern world. This vision appears to offer a new horizon, whereas, in fact it delivers to its target audience a finely tuned version of the already existing ambitions and aspirations of the target audience. The leader, with advisors, has examined the target audience and has used the results of extensive research and statistical methods concerning the group to form a picture of its members' lifestyles and values. On the basis of this information, the leader has built a "vision." The vision is intended to create an impression of a charismatic and transformational leader when, in fact, it is merely a response. The systemic, arithmetic, and statistical methods employed in this operation have led to the coining of the terms mathematical leader and mathematical vision.

  17. Visions of Vision: An Exploratory Study of the Role College and University Presidents Play in Developing Institutional Vision

    ERIC Educational Resources Information Center

    McWade, Jessica C.

    2014-01-01

    This qualitative research explores how college and university presidents engage in the process of developing formal institutional vision. The inquiry identifies roles presidents play in vision development, which is often undertaken as part of strategic-planning initiatives. Two constructs of leadership and institutional vision are used to examine…

  18. Light Vision Color

    NASA Astrophysics Data System (ADS)

    Valberg, Arne

    2005-04-01

    Light Vision Color takes a well-balanced, interdisciplinary approach to our most important sensory system. The book successfully combines basics in vision sciences with recent developments from different areas such as neuroscience, biophysics, sensory psychology and philosophy. Originally published in 1998 this edition has been extensively revised and updated to include new chapters on clinical problems and eye diseases, low vision rehabilitation and the basic molecular biology and genetics of colour vision. Takes a broad interdisciplinary approach combining basics in vision sciences with the most recent developments in the area Includes an extensive list of technical terms and explanations to encourage student understanding Successfully brings together the most important areas of the subject in to one volume

  19. Development of Accessible Laboratory Experiments for Students with Visual Impairments

    ERIC Educational Resources Information Center

    Kroes, KC; Lefler, Daniel; Schmitt, Aaron; Supalo, Cary A.

    2016-01-01

    The hands-on laboratory experiments are frequently what spark students' interest in science. Students who are blind or have low vision (BLV) typically do not get the same experience while participating in hands-on activities due to accessibility. Over the course of approximately nine months, common chemistry laboratory experiments were adapted and…

  20. Static and dynamic postural control in low-vision and normal-vision adults.

    PubMed

    Tomomitsu, Mônica S V; Alonso, Angelica Castilho; Morimoto, Eurica; Bobbio, Tatiana G; Greve, Julia M D

    2013-04-01

    This study aimed to evaluate the influence of reduced visual information on postural control by comparing low-vision and normal-vision adults in static and dynamic conditions. Twenty-five low-vision subjects and twenty-five normal sighted adults were evaluated for static and dynamic balance using four protocols: 1) the Modified Clinical Test of Sensory Interaction on Balance on firm and foam surfaces with eyes opened and closed; 2) Unilateral Stance with eyes opened and closed; 3) Tandem Walk; and 4) Step Up/Over. The results showed that the low-vision group presented greater body sway compared with the normal vision during balance on a foam surface (p≤0.001), the Unilateral Stance test for both limbs (p≤0.001), and the Tandem Walk test. The low-vision group showed greater step width (p≤0.001) and slower gait speed (p≤0.004). In the Step Up/Over task, low-vision participants were more cautious in stepping up (right p≤0.005 and left p≤0.009) and in executing the movement (p≤0.001). These findings suggest that visual feedback is crucial for determining balance, especially for dynamic tasks and on foam surfaces. Low-vision individuals had worse postural stability than normal-vision adults in terms of dynamic tests and balance on foam surfaces.

  1. 77 FR 16890 - Eighteenth Meeting: RTCA Special Committee 213, Enhanced Flight Visions Systems/Synthetic Vision...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-22

    ... Committee 213, Enhanced Flight Visions Systems/Synthetic Vision Systems (EFVS/SVS) AGENCY: Federal Aviation... 213, Enhanced Flight Visions Systems/Synthetic Vision Systems (EFVS/SVS). SUMMARY: The FAA is issuing... Flight Visions Systems/Synthetic Vision Systems (EFVS/SVS). DATES: The meeting will be held April 17-19...

  2. 77 FR 56254 - Twentieth Meeting: RTCA Special Committee 213, Enhanced Flight Vision Systems/Synthetic Vision...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-12

    ... Committee 213, Enhanced Flight Vision Systems/Synthetic Vision Systems (EFVS/SVS) AGENCY: Federal Aviation... 213, Enhanced Flight Vision Systems/Synthetic Vision Systems (EFVS/SVS). SUMMARY: The FAA is issuing... Flight Vision Systems/Synthetic Vision Systems (EFVS/SVS). DATES: The meeting will be held October 2-4...

  3. Acquired color vision deficiency.

    PubMed

    Simunovic, Matthew P

    2016-01-01

    Acquired color vision deficiency occurs as the result of ocular, neurologic, or systemic disease. A wide array of conditions may affect color vision, ranging from diseases of the ocular media through to pathology of the visual cortex. Traditionally, acquired color vision deficiency is considered a separate entity from congenital color vision deficiency, although emerging clinical and molecular genetic data would suggest a degree of overlap. We review the pathophysiology of acquired color vision deficiency, the data on its prevalence, theories for the preponderance of acquired S-mechanism (or tritan) deficiency, and discuss tests of color vision. We also briefly review the types of color vision deficiencies encountered in ocular disease, with an emphasis placed on larger or more detailed clinical investigations. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. The World Water Vision: From Developing a Vision to Action

    NASA Astrophysics Data System (ADS)

    Gangopadhyay, S.; Cosgrove, W.; Rijsberman, F.; Strzepek, K.; Strzepek, K.

    2001-05-01

    The World Water Vision exercise was initiated by the World Water Commission under the auspices of the World Water Council. The goal of the World Water Vision project was to develop a widely shared vision on the actions required to achieve a common set of water-related goals and the necessary commitment to carry out these actions. The Vision should be participatory in nature, including input from both developed and developing regions, with a special focus on the needs of the poor, women, youth, children and the environment. Three overall objectives were to: (i)raise awareness of water issues among both the general population and decision-makers so as to foster the necessary political will and leadership to tackle the problems seriously and systematically; (ii) develop a vision of water management for 2025 that is shared by water sector specialists as well as international, national and regional decision-makers in government, the private sector and civil society; and (iii) provide input to a Framework for Action to be elaborated by the Global Water Partnership, with steps to go from vision to action, including recommendations to funding agencies for investment priorities. This exercise was characterized by the principles of: (i) a participatory approach with extensive consultation; (ii) Innovative thinking; (iii) central analysis to assure integration and co-ordination; and (iv) emphasis on communication with groups outside the water sector. The primary activities included, developing global water scenarios that fed into regional consultations and sectoral consultations as water for food, water for people - water supply and sanitation, and water and environment. These consultations formulated the regional and sectoral visions that were synthesized to form the World Water Vision. The findings from this exercise were reported and debated at the Second World Water Forum and the Ministerial Conference held in The Hague, The Netherlands during April 2000. This paper

  5. FLORA™: Phase I development of a functional vision assessment for prosthetic vision users

    PubMed Central

    Geruschat, Duane R; Flax, Marshall; Tanna, Nilima; Bianchi, Michelle; Fisher, Andy; Goldschmidt, Mira; Fisher, Lynne; Dagnelie, Gislin; Deremeik, Jim; Smith, Audrey; Anaflous, Fatima; Dorn, Jessy

    2014-01-01

    Background Research groups and funding agencies need a functional assessment suitable for an ultra-low vision population in order to evaluate the impact of new vision restoration treatments. The purpose of this study was to develop a pilot assessment to capture the functional vision ability and well-being of subjects whose vision has been partially restored with the Argus II Retinal Prosthesis System. Methods The Functional Low-Vision Observer Rated Assessment (FLORA) pilot assessment involved a self-report section, a list of functional vision tasks for observation of performance, and a case narrative summary. Results were analyzed to determine whether the interview questions and functional vision tasks were appropriate for this ultra-low vision population and whether the ratings suffered from floor or ceiling effects. Thirty subjects with severe to profound retinitis pigmentosa (bare light perception or worse in both eyes) were enrolled in a clinical trial and implanted with the Argus II System. From this population, twenty-six subjects were assessed with the FLORA. Seven different evaluators administered the assessment. Results All 14 interview questions were asked. All 35 functional vision tasks were selected for evaluation at least once, with an average of 20 subjects being evaluated for each test item. All four rating options -- impossible (33%), difficult (23%), moderate (24%) and easy (19%) -- were used by the evaluators. Evaluators also judged the amount of vision they observed the subjects using to complete the various tasks, with vision only occurring 75% on average with the System ON, and 29% with the System OFF. Conclusion The first version of the FLORA was found to contain useful elements for evaluation and to avoid floor and ceiling effects. The next phase of development will be to refine the assessment and to establish reliability and validity to increase its value as a functional vision and well-being assessment tool. PMID:25675964

  6. Computational approaches to vision

    NASA Technical Reports Server (NTRS)

    Barrow, H. G.; Tenenbaum, J. M.

    1986-01-01

    Vision is examined in terms of a computational process, and the competence, structure, and control of computer vision systems are analyzed. Theoretical and experimental data on the formation of a computer vision system are discussed. Consideration is given to early vision, the recovery of intrinsic surface characteristics, higher levels of interpretation, and system integration and control. A computational visual processing model is proposed and its architecture and operation are described. Examples of state-of-the-art vision systems, which include some of the levels of representation and processing mechanisms, are presented.

  7. 77 FR 2342 - Seventeenth Meeting: RTCA Special Committee 213, Enhanced Flight Vision/Synthetic Vision Systems...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-17

    ... Committee 213, Enhanced Flight Vision/Synthetic Vision Systems (EFVS/SVS) AGENCY: Federal Aviation..., Enhanced Flight Vision/ Synthetic Vision Systems (EFVS/SVS). SUMMARY: The FAA is issuing this notice to advise the public of the seventeenth meeting of RTCA Special Committee 213, Enhanced Flight Vision...

  8. 78 FR 5557 - Twenty-First Meeting: RTCA Special Committee 213, Enhanced Flight Vision Systems/Synthetic Vision...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-25

    ... Committee 213, Enhanced Flight Vision Systems/Synthetic Vision Systems (EFVS/SVS) AGENCY: Federal Aviation... 213, Enhanced Flight Vision Systems/Synthetic Vision Systems (EFVS/SVS). SUMMARY: The FAA is issuing..., Enhanced Flight Vision Systems/Synthetic Vision Systems (EFVS/SVS). DATES: The meeting will be held...

  9. Progress in computer vision.

    NASA Astrophysics Data System (ADS)

    Jain, A. K.; Dorai, C.

    Computer vision has emerged as a challenging and important area of research, both as an engineering and a scientific discipline. The growing importance of computer vision is evident from the fact that it was identified as one of the "Grand Challenges" and also from its prominent role in the National Information Infrastructure. While the design of a general-purpose vision system continues to be elusive machine vision systems are being used successfully in specific application elusive, machine vision systems are being used successfully in specific application domains. Building a practical vision system requires a careful selection of appropriate sensors, extraction and integration of information from available cues in the sensed data, and evaluation of system robustness and performance. The authors discuss and demonstrate advantages of (1) multi-sensor fusion, (2) combination of features and classifiers, (3) integration of visual modules, and (IV) admissibility and goal-directed evaluation of vision algorithms. The requirements of several prominent real world applications such as biometry, document image analysis, image and video database retrieval, and automatic object model construction offer exciting problems and new opportunities to design and evaluate vision algorithms.

  10. Draper Laboratory small autonomous aerial vehicle

    NASA Astrophysics Data System (ADS)

    DeBitetto, Paul A.; Johnson, Eric N.; Bosse, Michael C.; Trott, Christian A.

    1997-06-01

    The Charles Stark Draper Laboratory, Inc. and students from Massachusetts Institute of Technology and Boston University have cooperated to develop an autonomous aerial vehicle that won the 1996 International Aerial Robotics Competition. This paper describes the approach, system architecture and subsystem designs for the entry. This entry represents a combination of many technology areas: navigation, guidance, control, vision processing, human factors, packaging, power, real-time software, and others. The aerial vehicle, an autonomous helicopter, performs navigation and control functions using multiple sensors: differential GPS, inertial measurement unit, sonar altimeter, and a flux compass. The aerial transmits video imagery to the ground. A ground based vision processor converts the image data into target position and classification estimates. The system was designed, built, and flown in less than one year and has provided many lessons about autonomous vehicle systems, several of which are discussed. In an appendix, our current research in augmenting the navigation system with vision- based estimates is presented.

  11. Computer vision

    NASA Technical Reports Server (NTRS)

    Gennery, D.; Cunningham, R.; Saund, E.; High, J.; Ruoff, C.

    1981-01-01

    The field of computer vision is surveyed and assessed, key research issues are identified, and possibilities for a future vision system are discussed. The problems of descriptions of two and three dimensional worlds are discussed. The representation of such features as texture, edges, curves, and corners are detailed. Recognition methods are described in which cross correlation coefficients are maximized or numerical values for a set of features are measured. Object tracking is discussed in terms of the robust matching algorithms that must be devised. Stereo vision, camera control and calibration, and the hardware and systems architecture are discussed.

  12. Biomimetic machine vision system.

    PubMed

    Harman, William M; Barrett, Steven F; Wright, Cameron H G; Wilcox, Michael

    2005-01-01

    Real-time application of digital imaging for use in machine vision systems has proven to be prohibitive when used within control systems that employ low-power single processors without compromising the scope of vision or resolution of captured images. Development of a real-time machine analog vision system is the focus of research taking place at the University of Wyoming. This new vision system is based upon the biological vision system of the common house fly. Development of a single sensor is accomplished, representing a single facet of the fly's eye. This new sensor is then incorporated into an array of sensors capable of detecting objects and tracking motion in 2-D space. This system "preprocesses" incoming image data resulting in minimal data processing to determine the location of a target object. Due to the nature of the sensors in the array, hyperacuity is achieved thereby eliminating resolutions issues found in digital vision systems. In this paper, we will discuss the biological traits of the fly eye and the specific traits that led to the development of this machine vision system. We will also discuss the process of developing an analog based sensor that mimics the characteristics of interest in the biological vision system. This paper will conclude with a discussion of how an array of these sensors can be applied toward solving real-world machine vision issues.

  13. Aging and Vision

    PubMed Central

    Owsley, Cynthia

    2010-01-01

    Given the increasing size of the older adult population in many countries, there is a pressing need to identify the nature of aging-related vision impairments, their underlying mechanisms, and how they impact older adults’ performance of everyday visual tasks. The results of this research can then be used to develop and evaluate interventions to slow or reverse aging-related declines in vision, thereby improving quality of life. Here we summarize salient developments in research on aging and vision over the past 25 years, focusing on spatial contrast sensitivity, vision under low luminance, temporal sensitivity and motion perception, and visual processing speed. PMID:20974168

  14. Microwave vision for robots

    NASA Technical Reports Server (NTRS)

    Lewandowski, Leon; Struckman, Keith

    1994-01-01

    Microwave Vision (MV), a concept originally developed in 1985, could play a significant role in the solution to robotic vision problems. Originally our Microwave Vision concept was based on a pattern matching approach employing computer based stored replica correlation processing. Artificial Neural Network (ANN) processor technology offers an attractive alternative to the correlation processing approach, namely the ability to learn and to adapt to changing environments. This paper describes the Microwave Vision concept, some initial ANN-MV experiments, and the design of an ANN-MV system that has led to a second patent disclosure in the robotic vision field.

  15. Laboratory analysis of phacoemulsifier compliance and capacity.

    PubMed

    Nejad, Mitra; Injev, Valentine P; Miller, Kevin M

    2012-11-01

    To compare the compliance and capacity of 7 fluidics modules used by 6 phacoemulsifiers from 3 manufacturers. Jules Stein Eye Institute, Los Angeles, California, USA. Experimental study. Previous-model and current-model phacoemulsifiers from 3 manufacturers were subjected to laboratory analysis of compliance and capacity. Previous-generation models tested included the Legacy Advantec, Whitestar Sovereign Phacoemulsification System, and Millennium Microsurgical System. Current models tested were the Infiniti Vision System with standard and Intrepid cassettes, Whitestar Signature Phacoemulsification System, and Stellaris Vision Enhancement System. To measure compliance, the aspiration line was connected to an electronic pressure transducer and small volumes of fluid were injected or aspirated. To measure capacity, the space between the distal end of the aspiration line and the pump was filled with methylene blue-dyed fluid. The Legacy was the most compliant phacoemulsifier. The old and new Whitestar systems, Millennium system, and Stellaris system showed similar midrange compliances. The Infiniti Vision System with the Intrepid fluidic management system was the least compliant. The Infiniti cassettes had the greatest capacity, which is a detriment from a surge-control perspective, and Signature cassettes had the least capacity. The Infiniti Intrepid system had the lowest compliance of the 6 units tested, which is optimum from a surge-control perspective. All other things being equal, the Infiniti should have the safest occlusion-break surge response. Mr. Injev is an employee of Alcon Laboratories. Dr. Miller is a consultant to and investigator for Alcon Laboratories. Ms. Nejad has no financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. The CCH Vision Stimulation Program for Infants with Low Vision: Preliminary Results.

    ERIC Educational Resources Information Center

    Leguire, L. E.; And Others

    1992-01-01

    This study evaluated the Columbus (Ohio) Children's Hospital vision stimulation program, involving in-home intervention with 15 visually impaired infants. Comparison with controls indicated benefits of appropriate vision stimulation in increasing the neural foundation for vision and visual-motor function in visually impaired infants. (Author/DB)

  17. Laboratory Directed Research and Development Annual Report for 2009

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hughes, Pamela J.

    This report documents progress made on all LDRD-funded projects during fiscal year 2009. As a US Department of Energy (DOE) Office of Science (SC) national laboratory, Pacific Northwest National Laboratory (PNNL) has an enduring mission to bring molecular and environmental sciences and engineering strengths to bear on DOE missions and national needs. Their vision is to be recognized worldwide and valued nationally for leadership in accelerating the discovery and deployment of solutions to challenges in energy, national security, and the environment. To achieve this mission and vision, they provide distinctive, world-leading science and technology in: (1) the design and scalablemore » synthesis of materials and chemicals; (2) climate change science and emissions management; (3) efficient and secure electricity management from generation to end use; and (4) signature discovery and exploitation for threat detection and reduction. PNNL leadership also extends to operating EMSL: the Environmental Molecular Sciences Laboratory, a national scientific user facility dedicated to providing itnegrated experimental and computational resources for discovery and technological innovation in the environmental molecular sciences.« less

  18. Agnosic vision is like peripheral vision, which is limited by crowding.

    PubMed

    Strappini, Francesca; Pelli, Denis G; Di Pace, Enrico; Martelli, Marialuisa

    2017-04-01

    Visual agnosia is a neuropsychological impairment of visual object recognition despite near-normal acuity and visual fields. A century of research has provided only a rudimentary account of the functional damage underlying this deficit. We find that the object-recognition ability of agnosic patients viewing an object directly is like that of normally-sighted observers viewing it indirectly, with peripheral vision. Thus, agnosic vision is like peripheral vision. We obtained 14 visual-object-recognition tests that are commonly used for diagnosis of visual agnosia. Our "standard" normal observer took these tests at various eccentricities in his periphery. Analyzing the published data of 32 apperceptive agnosia patients and a group of 14 posterior cortical atrophy (PCA) patients on these tests, we find that each patient's pattern of object recognition deficits is well characterized by one number, the equivalent eccentricity at which our standard observer's peripheral vision is like the central vision of the agnosic patient. In other words, each agnosic patient's equivalent eccentricity is conserved across tests. Across patients, equivalent eccentricity ranges from 4 to 40 deg, which rates severity of the visual deficit. In normal peripheral vision, the required size to perceive a simple image (e.g., an isolated letter) is limited by acuity, and that for a complex image (e.g., a face or a word) is limited by crowding. In crowding, adjacent simple objects appear unrecognizably jumbled unless their spacing exceeds the crowding distance, which grows linearly with eccentricity. Besides conservation of equivalent eccentricity across object-recognition tests, we also find conservation, from eccentricity to agnosia, of the relative susceptibility of recognition of ten visual tests. These findings show that agnosic vision is like eccentric vision. Whence crowding? Peripheral vision, strabismic amblyopia, and possibly apperceptive agnosia are all limited by crowding, making it

  19. Implementing the President's Vision: JPL and NASA's Exploration Systems Mission Directorate

    NASA Technical Reports Server (NTRS)

    Sander, Michael J.

    2006-01-01

    As part of the NASA team the Jet Propulsion Laboratory is involved in the Exploration Systems Mission Directorate (ESMD) work to implement the President's Vision for Space exploration. In this slide presentation the roles that are assigned to the various NASA centers to implement the vision are reviewed. The plan for JPL is to use the Constellation program to advance the combination of science an Constellation program objectives. JPL's current participation is to contribute systems engineering support, Command, Control, Computing and Information (C3I) architecture, Crew Exploration Vehicle, (CEV) Thermal Protection System (TPS) project support/CEV landing assist support, Ground support systems support at JSC and KSC, Exploration Communication and Navigation System (ECANS), Flight prototypes for cabin atmosphere instruments

  20. Barriers to accessing low vision services.

    PubMed

    Pollard, Tamara L; Simpson, John A; Lamoureux, Ecosse L; Keeffe, Jill E

    2003-07-01

    To investigate barriers to accessing low vision services in Australia. Adults with a vision impairment (<6/12 in the better eye and/or significant visual field defect), who were current patients at the Royal Victorian Eye and Ear Hospital (RVEEH), were interviewed. The questions investigated self-perceived vision difficulties, duration of vision loss and satisfaction with vision and also examined issues of awareness of low vision services and referral to services. Focus groups were also conducted with vision impaired (<6/12 in the better eye) patients from the RVEEH, listeners of the Radio for the Print Handicapped and peer workers at Vision Australia Foundation. The discussions were recorded and transcribed. The questionnaire revealed that referral to low vision services was associated with a greater degree of vision loss (p = 0.002) and a greater self-perception of low vision (p = 0.005) but that referral was not associated with satisfaction (p = 0.144) or difficulties related to vision (p = 0.169). Participants with mild and moderate vision impairment each reported similar levels of difficulties with daily activities and satisfaction with their vision (p > 0.05). However, there was a significant difference in the level of difficulties experienced with daily activities between those with mild-moderate and severe vision impairment (p < 0.05). The participants of the focus groups identified barriers to accessing low vision services related to awareness of services among the general public and eye care professionals, understanding of low vision and the services available, acceptance of low vision, the referral process, and transport. In addition to the expected difficulties with lack of awareness of services by people with low vision, many people do not understand what the services provide and do not identify themselves as having low vision. Knowledge of these barriers, from the perspective of people with low vision, can now be used to guide the development and

  1. Peripheral vision of youths with low vision: motion perception, crowding, and visual search.

    PubMed

    Tadin, Duje; Nyquist, Jeffrey B; Lusk, Kelly E; Corn, Anne L; Lappin, Joseph S

    2012-08-24

    Effects of low vision on peripheral visual function are poorly understood, especially in children whose visual skills are still developing. The aim of this study was to measure both central and peripheral visual functions in youths with typical and low vision. Of specific interest was the extent to which measures of foveal function predict performance of peripheral tasks. We assessed central and peripheral visual functions in youths with typical vision (n = 7, ages 10-17) and low vision (n = 24, ages 9-18). Experimental measures used both static and moving stimuli and included visual crowding, visual search, motion acuity, motion direction discrimination, and multitarget motion comparison. In most tasks, visual function was impaired in youths with low vision. Substantial differences, however, were found both between participant groups and, importantly, across different tasks within participant groups. Foveal visual acuity was a modest predictor of peripheral form vision and motion sensitivity in either the central or peripheral field. Despite exhibiting normal motion discriminations in fovea, motion sensitivity of youths with low vision deteriorated in the periphery. This contrasted with typically sighted participants, who showed improved motion sensitivity with increasing eccentricity. Visual search was greatly impaired in youths with low vision. Our results reveal a complex pattern of visual deficits in peripheral vision and indicate a significant role of attentional mechanisms in observed impairments. These deficits were not adequately captured by measures of foveal function, arguing for the importance of independently assessing peripheral visual function.

  2. Vision restoration after brain and retina damage: the "residual vision activation theory".

    PubMed

    Sabel, Bernhard A; Henrich-Noack, Petra; Fedorov, Anton; Gall, Carolin

    2011-01-01

    Vision loss after retinal or cerebral visual injury (CVI) was long considered to be irreversible. However, there is considerable potential for vision restoration and recovery even in adulthood. Here, we propose the "residual vision activation theory" of how visual functions can be reactivated and restored. CVI is usually not complete, but some structures are typically spared by the damage. They include (i) areas of partial damage at the visual field border, (ii) "islands" of surviving tissue inside the blind field, (iii) extrastriate pathways unaffected by the damage, and (iv) downstream, higher-level neuronal networks. However, residual structures have a triple handicap to be fully functional: (i) fewer neurons, (ii) lack of sufficient attentional resources because of the dominant intact hemisphere caused by excitation/inhibition dysbalance, and (iii) disturbance in their temporal processing. Because of this resulting activation loss, residual structures are unable to contribute much to everyday vision, and their "non-use" further impairs synaptic strength. However, residual structures can be reactivated by engaging them in repetitive stimulation by different means: (i) visual experience, (ii) visual training, or (iii) noninvasive electrical brain current stimulation. These methods lead to strengthening of synaptic transmission and synchronization of partially damaged structures (within-systems plasticity) and downstream neuronal networks (network plasticity). Just as in normal perceptual learning, synaptic plasticity can improve vision and lead to vision restoration. This can be induced at any time after the lesion, at all ages and in all types of visual field impairments after retinal or brain damage (stroke, neurotrauma, glaucoma, amblyopia, age-related macular degeneration). If and to what extent vision restoration can be achieved is a function of the amount of residual tissue and its activation state. However, sustained improvements require repetitive

  3. Filtering and polychromatic vision in mantis shrimps: themes in visible and ultraviolet vision.

    PubMed

    Cronin, Thomas W; Bok, Michael J; Marshall, N Justin; Caldwell, Roy L

    2014-01-01

    Stomatopod crustaceans have the most complex and diverse assortment of retinal photoreceptors of any animals, with 16 functional classes. The receptor classes are subdivided into sets responsible for ultraviolet vision, spatial vision, colour vision and polarization vision. Many of these receptor classes are spectrally tuned by filtering pigments located in photoreceptors or overlying optical elements. At visible wavelengths, carotenoproteins or similar substances are packed into vesicles used either as serial, intrarhabdomal filters or lateral filters. A single retina may contain a diversity of these filtering pigments paired with specific photoreceptors, and the pigments used vary between and within species both taxonomically and ecologically. Ultraviolet-filtering pigments in the crystalline cones serve to tune ultraviolet vision in these animals as well, and some ultraviolet receptors themselves act as birefringent filters to enable circular polarization vision. Stomatopods have reached an evolutionary extreme in their use of filter mechanisms to tune photoreception to habitat and behaviour, allowing them to extend the spectral range of their vision both deeper into the ultraviolet and further into the red.

  4. Evolutionary replacement of UV vision by violet vision in fish.

    PubMed

    Tada, Takashi; Altun, Ahmet; Yokoyama, Shozo

    2009-10-13

    The vertebrate ancestor possessed ultraviolet (UV) vision and many species have retained it during evolution. Many other species switched to violet vision and, then again, some avian species switched back to UV vision. These UV and violet vision are mediated by short wavelength-sensitive (SWS1) pigments that absorb light maximally (lambda(max)) at approximately 360 and 390-440 nm, respectively. It is not well understood why and how these functional changes have occurred. Here, we cloned the pigment of scabbardfish (Lepidopus fitchi) with a lambda(max) of 423 nm, an example of violet-sensitive SWS1 pigment in fish. Mutagenesis experiments and quantum mechanical/molecular mechanical (QM/MM) computations show that the violet-sensitivity was achieved by the deletion of Phe-86 that converted the unprotonated Schiff base-linked 11-cis-retinal to a protonated form. The finding of a violet-sensitive SWS1 pigment in scabbardfish suggests that many other fish also have orthologous violet pigments. The isolation and comparison of such violet and UV pigments in fish living in different ecological habitats will open an unprecedented opportunity to elucidate not only the molecular basis of phenotypic adaptations, but also the genetics of UV and violet vision.

  5. Vision Care and the Nation's Children.

    ERIC Educational Resources Information Center

    American Optometric Association, St. Louis, MO.

    Aspects of vision and vision care considered are the following: extent and types of vision defects of American children; importance of vision care in pre-school years, elementary, and secondary school and beyond; and manpower resources in vision care today, the extent of vision testing and care, special problem areas, and governmental support.…

  6. Federal regulation of vision enhancement devices for normal and abnormal vision

    NASA Astrophysics Data System (ADS)

    Drum, Bruce

    2006-09-01

    The Food and Drug Administration (FDA) evaluates the safety and effectiveness of medical devices and biological products as well as food and drugs. The FDA defines a device as a product that is intended, by physical means, to diagnose, treat, or prevent disease, or to affect the structure or function of the body. All vision enhancement devices fulfill this definition because they are intended to affect a function (vision) of the body. In practice, however, FDA historically has drawn a distinction between devices that are intended to enhance low vision as opposed to normal vision. Most low vision aids are therapeutic devices intended to compensate for visual impairment, and are actively regulated according to their level of risk to the patient. The risk level is usually low (e.g. Class I, exempt from 510(k) submission requirements for magnifiers that do not touch the eye), but can be as high as Class III (requiring a clinical trial and Premarket Approval (PMA) application) for certain implanted and prosthetic devices (e.g. intraocular telescopes and prosthetic retinal implants). In contrast, the FDA usually does not actively enforce its regulations for devices that are intended to enhance normal vision, are low risk, and do not have a medical intended use. However, if an implanted or prosthetic device were developed for enhancing normal vision, the FDA would likely decide to regulate it actively, because its intended use would entail a substantial medical risk to the user. Companies developing such devices should contact the FDA at an early stage to clarify their regulatory status.

  7. Peripheral Vision of Youths with Low Vision: Motion Perception, Crowding, and Visual Search

    PubMed Central

    Tadin, Duje; Nyquist, Jeffrey B.; Lusk, Kelly E.; Corn, Anne L.; Lappin, Joseph S.

    2012-01-01

    Purpose. Effects of low vision on peripheral visual function are poorly understood, especially in children whose visual skills are still developing. The aim of this study was to measure both central and peripheral visual functions in youths with typical and low vision. Of specific interest was the extent to which measures of foveal function predict performance of peripheral tasks. Methods. We assessed central and peripheral visual functions in youths with typical vision (n = 7, ages 10–17) and low vision (n = 24, ages 9–18). Experimental measures used both static and moving stimuli and included visual crowding, visual search, motion acuity, motion direction discrimination, and multitarget motion comparison. Results. In most tasks, visual function was impaired in youths with low vision. Substantial differences, however, were found both between participant groups and, importantly, across different tasks within participant groups. Foveal visual acuity was a modest predictor of peripheral form vision and motion sensitivity in either the central or peripheral field. Despite exhibiting normal motion discriminations in fovea, motion sensitivity of youths with low vision deteriorated in the periphery. This contrasted with typically sighted participants, who showed improved motion sensitivity with increasing eccentricity. Visual search was greatly impaired in youths with low vision. Conclusions. Our results reveal a complex pattern of visual deficits in peripheral vision and indicate a significant role of attentional mechanisms in observed impairments. These deficits were not adequately captured by measures of foveal function, arguing for the importance of independently assessing peripheral visual function. PMID:22836766

  8. Low Vision Tips

    MedlinePlus

    ... this page: https://medlineplus.gov/lowvision.html MedlinePlus: Low Vision Tips We are sorry. MedlinePlus no longer maintains the For Low Vision Users page. You will still find health resources ...

  9. Behavioural evidence of colour vision in free flying stingless bees.

    PubMed

    Spaethe, J; Streinzer, M; Eckert, J; May, S; Dyer, A G

    2014-06-01

    Colour vision was first demonstrated with behavioural experiments in honeybees 100 years ago. Since that time a wealth of quality physiological data has shown a highly conserved set of trichromatic colour receptors in most bee species. Despite the subsequent wealth of behavioural research on honeybees and bumblebees, there currently is a relative dearth of data on stingless bees, which are the largest tribe of the eusocial bees comprising of more than 600 species. In our first experiment we tested Trigona cf. fuscipennis, a stingless bee species from Costa Rica in a field setting using the von Frisch method and show functional colour vision. In a second experiment with these bees, we use a simultaneous colour discrimination test designed for honeybees to enable a comparative analysis of relative colour discrimination. In a third experiment, we test in laboratory conditions Tetragonula carbonaria, an Australian stingless bee species using a similar simultaneous colour discrimination test. Both stingless bee species show relatively poorer colour discrimination compared to honeybees and bumblebees; and we discuss the value of being able to use these behavioural methods to efficiently extend our current knowledge of colour vision and discrimination in different bee species.

  10. VISION AND COLLEGE READING - A REVIEW OF THE LITERATURE AND REPORT OF A SURVEY.

    ERIC Educational Resources Information Center

    MAXWELL, MARTHA J.

    THE AMERICAN OPTICAL (AO) COMPANY'S SIGHT SCREENER, A PORTABLE BINOCULAR INSTRUMENT DESIGNED FOR MASS VISION TESTING, WAS EVALUATED AT THE UNIVERSITY OF MARYLAND READING AND STUDY SKILLS LABORATORY TO DETERMINE ITS CAPACITY TO IDENTIFY STUDENTS NEEDING PROFESSIONAL EYE EXAMINATIONS PRIOR TO READING INSTRUCTION. DATA FROM 106 PROBATIONARY FRESHMEN,…

  11. Low vision in east African blind school students: need for optical low vision services.

    PubMed

    Silver, J; Gilbert, C E; Spoerer, P; Foster, A

    1995-09-01

    There is increasing awareness of the needs of children with low vision, particularly in developing countries where programmes of integrated education are being developed. However, appropriate low vision services are usually not available or affordable. The aims of this study were, firstly, to assess the need for spectacles and optical low vision devices in students with low vision in schools for the blind in Kenya and Uganda; secondly, to evaluate inexpensive locally produced low vision devices; and, finally, to evaluate simple methods of identifying those low vision students who could read N5 to N8 print after low vision assessment. A total of 230 students were examined (51 school and 16 university students in Uganda and 163 students in Kenya, aged 5-22 years), 147 of whom had a visual acuity of less than 6/18 to perception of light in the better eye at presentation. After refraction seven of the 147 achieved 6/18 or better. Eighty two (58.6%) of the 140 students with low vision (corrected visual acuity in the better eye of less than 6/18 to light perception) had refractive errors of more than 2 dioptres in the better eye, and 38 (27.1%) had more than 2 dioptres of astigmatism. Forty six per cent of students with low vision (n = 64) could read N5-N8 print unaided or with spectacles, as could a further 33% (n = 46) with low vision devices. Low vision devices were indicated in a total of 50 students (35.7%). The locally manufactured devices could meet two thirds of the need. A corrected distance acuity of 1/60 or better had a sensitivity of 99.1% and a specificity of 56.7% in predicting the ability to discern N8 print or better. The ability to perform at least two of the three simple tests of functional vision had a sensitivity of 95.5% and a specificity of 63.3% in identifying the students able to discern N8 or better.

  12. Head-Mounted Display Technology for Low Vision Rehabilitation and Vision Enhancement

    PubMed Central

    Ehrlich, Joshua R.; Ojeda, Lauro V.; Wicker, Donna; Day, Sherry; Howson, Ashley; Lakshminarayanan, Vasudevan; Moroi, Sayoko E.

    2017-01-01

    Purpose To describe the various types of head-mounted display technology, their optical and human factors considerations, and their potential for use in low vision rehabilitation and vision enhancement. Design Expert perspective. Methods An overview of head-mounted display technology by an interdisciplinary team of experts drawing on key literature in the field. Results Head-mounted display technologies can be classified based on their display type and optical design. See-through displays such as retinal projection devices have the greatest potential for use as low vision aids. Devices vary by their relationship to the user’s eyes, field of view, illumination, resolution, color, stereopsis, effect on head motion and user interface. These optical and human factors considerations are important when selecting head-mounted displays for specific applications and patient groups. Conclusions Head-mounted display technologies may offer advantages over conventional low vision aids. Future research should compare head-mounted displays to commonly prescribed low vision aids in order to compare their effectiveness in addressing the impairments and rehabilitation goals of diverse patient populations. PMID:28048975

  13. Leading Vision

    ERIC Educational Resources Information Center

    Fawcett, Gay

    2004-01-01

    The current educational landscape makes it imperative that a vision statement become more than a fine-sounding statement that is laminated, hung on the wall, and quickly forgotten. If educators do not have a clear image of the future they wish to create, then someone will be ready to create it for them. But with a clear vision of the future, a…

  14. Biofeedback for Better Vision

    NASA Technical Reports Server (NTRS)

    1990-01-01

    Biofeedtrac, Inc.'s Accommotrac Vision Trainer, invented by Dr. Joseph Trachtman, is based on vision research performed by Ames Research Center and a special optometer developed for the Ames program by Stanford Research Institute. In the United States, about 150 million people are myopes (nearsighted), who tend to overfocus when they look at distant objects causing blurry distant vision, or hyperopes (farsighted), whose vision blurs when they look at close objects because they tend to underfocus. The Accommotrac system is an optical/electronic system used by a doctor as an aid in teaching a patient how to contract and relax the ciliary body, the focusing muscle. The key is biofeedback, wherein the patient learns to control a bodily process or function he is not normally aware of. Trachtman claims a 90 percent success rate for correcting, improving or stopping focusing problems. The Vision Trainer has also proved effective in treating other eye problems such as eye oscillation, cross eyes, and lazy eye and in professional sports to improve athletes' peripheral vision and reaction time.

  15. Alternatives to Pyrotechnic Distress Signals; Laboratory and Field Studies

    DTIC Science & Technology

    2015-03-01

    using night vision imaging systems (NVIS) with “minus-blue” filtering,” the project recommends additional research and testing leading to the inclusion...18  5.2.3  Background Images ...Example of image capture from radiant imaging colorimeter. ....................................................... 16  Figure 10. Laboratory setup

  16. Laboratory directed research and development FY98 annual report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Al-Ayat, R; Holzrichter, J

    1999-05-01

    In 1984, Congress and the Department of Energy (DOE) established the Laboratory Directed Research and Development (LDRD) Program to enable the director of a national laboratory to foster and expedite innovative research and development (R and D) in mission areas. The Lawrence Livermore National Laboratory (LLNL) continually examines these mission areas through strategic planning and shapes the LDRD Program to meet its long-term vision. The goal of the LDRD Program is to spur development of new scientific and technical capabilities that enable LLNL to respond to the challenges within its evolving mission areas. In addition, the LDRD Program provides LLNLmore » with the flexibility to nurture and enrich essential scientific and technical competencies and enables the Laboratory to attract the most qualified scientists and engineers. The FY98 LDRD portfolio described in this annual report has been carefully structured to continue the tradition of vigorously supporting DOE and LLNL strategic vision and evolving mission areas. The projects selected for LDRD funding undergo stringent review and selection processes, which emphasize strategic relevance and require technical peer reviews of proposals by external and internal experts. These FY98 projects emphasize the Laboratory's national security needs: stewardship of the U.S. nuclear weapons stockpile, responsibility for the counter- and nonproliferation of weapons of mass destruction, development of high-performance computing, and support of DOE environmental research and waste management programs.« less

  17. (Computer) Vision without Sight

    PubMed Central

    Manduchi, Roberto; Coughlan, James

    2012-01-01

    Computer vision holds great promise for helping persons with blindness or visual impairments (VI) to interpret and explore the visual world. To this end, it is worthwhile to assess the situation critically by understanding the actual needs of the VI population and which of these needs might be addressed by computer vision. This article reviews the types of assistive technology application areas that have already been developed for VI, and the possible roles that computer vision can play in facilitating these applications. We discuss how appropriate user interfaces are designed to translate the output of computer vision algorithms into information that the user can quickly and safely act upon, and how system-level characteristics affect the overall usability of an assistive technology. Finally, we conclude by highlighting a few novel and intriguing areas of application of computer vision to assistive technology. PMID:22815563

  18. Beauty and cuteness in peripheral vision

    PubMed Central

    Kuraguchi, Kana; Ashida, Hiroshi

    2015-01-01

    Guo et al. (2011) showed that attractiveness was detectable in peripheral vision. Since there are different types of attractiveness (Rhodes, 2006), we investigated how beauty and cuteness are detected in peripheral vision with a brief presentation. Participants (n = 45) observed two Japanese female faces for 100 ms, then were asked to respond which face was more beautiful (or cuter). The results indicated that both beauty and cuteness were detectable in peripheral vision, but not in the same manner. Discrimination rates for judging beauty were invariant in peripheral and central vision, while discrimination rates for judging cuteness declined in peripheral vision as compared with central vision. This was not explained by lower resolution in peripheral vision. In addition, for male participants, it was more difficult to judge cuteness than beauty in peripheral vision, thus suggesting that gender differences can have a certain effect when judging cuteness. Therefore, central vision might be suitable for judging cuteness while judging beauty might not be affected by either central or peripheral vision. This might be related with the functional difference between beauty and cuteness. PMID:25999883

  19. Flight Test Comparison Between Enhanced Vision (FLIR) and Synthetic Vision Systems

    NASA Technical Reports Server (NTRS)

    Arthur, Jarvis J., III; Kramer, Lynda J.; Bailey, Randall E.

    2005-01-01

    Limited visibility and reduced situational awareness have been cited as predominant causal factors for both Controlled Flight Into Terrain (CFIT) and runway incursion accidents. NASA s Synthetic Vision Systems (SVS) project is developing practical application technologies with the goal of eliminating low visibility conditions as a causal factor to civil aircraft accidents while replicating the operational benefits of clear day flight operations, regardless of the actual outside visibility condition. A major thrust of the SVS project involves the development/demonstration of affordable, certifiable display configurations that provide intuitive out-the-window terrain and obstacle information with advanced pathway guidance. A flight test evaluation was conducted in the summer of 2004 by NASA Langley Research Center under NASA s Aviation Safety and Security, Synthetic Vision System - Commercial and Business program. A Gulfstream G-V aircraft, modified and operated under NASA contract by the Gulfstream Aerospace Corporation, was flown over a 3-week period at the Reno/Tahoe International Airport and an additional 3-week period at the NASA Wallops Flight Facility to evaluate integrated Synthetic Vision System concepts. Flight testing was conducted to evaluate the performance, usability, and acceptance of an integrated synthetic vision concept which included advanced Synthetic Vision display concepts for a transport aircraft flight deck, a Runway Incursion Prevention System, an Enhanced Vision Systems (EVS), and real-time Database Integrity Monitoring Equipment. This paper focuses on comparing qualitative and subjective results between EVS and SVS display concepts.

  20. Present Vision--Future Vision.

    ERIC Educational Resources Information Center

    Fitterman, L. Jeffrey

    This paper addresses issues of current and future technology use for and by individuals with visual impairments and blindness in Florida. Present technology applications used in vision programs in Florida are individually described, including video enlarging, speech output, large inkprint, braille print, paperless braille, and tactual output…

  1. Efficacy of vision therapy in children with learning disability and associated binocular vision anomalies.

    PubMed

    Hussaindeen, Jameel Rizwana; Shah, Prerana; Ramani, Krishna Kumar; Ramanujan, Lalitha

    To report the frequency of binocular vision (BV) anomalies in children with specific learning disorders (SLD) and to assess the efficacy of vision therapy (VT) in children with a non-strabismic binocular vision anomaly (NSBVA). The study was carried out at a centre for learning disability (LD). Comprehensive eye examination and binocular vision assessment was carried out for 94 children (mean (SD) age: 15 (2.2) years) diagnosed with specific learning disorder. BV assessment was done for children with best corrected visual acuity of ≥6/9 - N6, cooperative for examination and free from any ocular pathology. For children with a diagnosis of NSBVA (n=46), 24 children were randomized to VT and no intervention was provided to the other 22 children who served as experimental controls. At the end of 10 sessions of vision therapy, BV assessment was performed for both the intervention and non-intervention groups. Binocular vision anomalies were found in 59 children (62.8%) among which 22% (n=13) had strabismic binocular vision anomalies (SBVA) and 78% (n=46) had a NSBVA. Accommodative infacility (AIF) was the commonest of the NSBVA and found in 67%, followed by convergence insufficiency (CI) in 25%. Post-vision therapy, the intervention group showed significant improvement in all the BV parameters (Wilcoxon signed rank test, p<0.05) except negative fusional vergence. Children with specific learning disorders have a high frequency of binocular vision disorders and vision therapy plays a significant role in improving the BV parameters. Children with SLD should be screened for BV anomalies as it could potentially be an added hindrance to the reading difficulty in this special population. Copyright © 2017 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.

  2. Low Vision Aids in Glaucoma

    PubMed Central

    Khanna, Anjani

    2012-01-01

    A large number of glaucoma patients suffer from vision impairments that qualify as low vision. Additional difficulties associated with low vision include problems with glare, lighting, and contrast, which can make daily activities extremely challenging. This article elaborates on how low vision aids can help with various tasks that visually impaired glaucoma patients need to do each day, to take care of themselves and to lead an independent life. PMID:27990068

  3. An Operationally Based Vision Assessment Simulator for Domes

    NASA Technical Reports Server (NTRS)

    Archdeacon, John; Gaska, James; Timoner, Samson

    2012-01-01

    The Operational Based Vision Assessment (OBVA) simulator was designed and built by NASA and the United States Air Force (USAF) to provide the Air Force School of Aerospace Medicine (USAFSAM) with a scientific testing laboratory to study human vision and testing standards in an operationally relevant environment. This paper describes the general design objectives and implementation characteristics of the simulator visual system being created to meet these requirements. A key design objective for the OBVA research simulator is to develop a real-time computer image generator (IG) and display subsystem that can display and update at 120 frame s per second (design target), or at a minimum, 60 frames per second, with minimal transport delay using commercial off-the-shelf (COTS) technology. There are three key parts of the OBVA simulator that are described in this paper: i) the real-time computer image generator, ii) the various COTS technology used to construct the simulator, and iii) the spherical dome display and real-time distortion correction subsystem. We describe the various issues, possible COTS solutions, and remaining problem areas identified by NASA and the USAF while designing and building the simulator for future vision research. We also describe the critically important relationship of the physical display components including distortion correction for the dome consistent with an objective of minimizing latency in the system. The performance of the automatic calibration system used in the dome is also described. Various recommendations for possible future implementations shall also be discussed.

  4. Vision Problems in Homeless Children.

    PubMed

    Smith, Natalie L; Smith, Thomas J; DeSantis, Diana; Suhocki, Marissa; Fenske, Danielle

    2015-08-01

    Vision problems in homeless children can decrease educational achievement and quality of life. To estimate the prevalence and specific diagnoses of vision problems in children in an urban homeless shelter. A prospective series of 107 homeless children and teenagers who underwent screening with a vision questionnaire, eye chart screening (if mature enough) and if vision problem suspected, evaluation by a pediatric ophthalmologist. Glasses and other therapeutic interventions were provided if necessary. The prevalence of vision problems in this population was 25%. Common diagnoses included astigmatism, amblyopia, anisometropia, myopia, and hyperopia. Glasses were required and provided for 24 children (22%). Vision problems in homeless children are common and frequently correctable with ophthalmic intervention. Evaluation by pediatric ophthalmologist is crucial for accurate diagnoses and treatment. Our system of screening and evaluation is feasible, efficacious, and reproducible in other homeless care situations.

  5. Power Systems Life Cycle Analysis Tool (Power L-CAT).

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andruski, Joel; Drennen, Thomas E.

    2011-01-01

    The Power Systems L-CAT is a high-level dynamic model that calculates levelized production costs and tracks environmental performance for a range of electricity generation technologies: natural gas combined cycle (using either imported (LNGCC) or domestic natural gas (NGCC)), integrated gasification combined cycle (IGCC), supercritical pulverized coal (SCPC), existing pulverized coal (EXPC), nuclear, and wind. All of the fossil fuel technologies also include an option for including carbon capture and sequestration technologies (CCS). The model allows for quick sensitivity analysis on key technical and financial assumptions, such as: capital, O&M, and fuel costs; interest rates; construction time; heat rates; taxes; depreciation;more » and capacity factors. The fossil fuel options are based on detailed life cycle analysis reports conducted by the National Energy Technology Laboratory (NETL). For each of these technologies, NETL's detailed LCAs include consideration of five stages associated with energy production: raw material acquisition (RMA), raw material transport (RMT), energy conversion facility (ECF), product transportation and distribution (PT&D), and end user electricity consumption. The goal of the NETL studies is to compare existing and future fossil fuel technology options using a cradle-to-grave analysis. The NETL reports consider constant dollar levelized cost of delivered electricity, total plant costs, greenhouse gas emissions, criteria air pollutants, mercury (Hg) and ammonia (NH3) emissions, water withdrawal and consumption, and land use (acreage).« less

  6. A High-Speed Vision-Based Sensor for Dynamic Vibration Analysis Using Fast Motion Extraction Algorithms.

    PubMed

    Zhang, Dashan; Guo, Jie; Lei, Xiujun; Zhu, Changan

    2016-04-22

    The development of image sensor and optics enables the application of vision-based techniques to the non-contact dynamic vibration analysis of large-scale structures. As an emerging technology, a vision-based approach allows for remote measuring and does not bring any additional mass to the measuring object compared with traditional contact measurements. In this study, a high-speed vision-based sensor system is developed to extract structure vibration signals in real time. A fast motion extraction algorithm is required for this system because the maximum sampling frequency of the charge-coupled device (CCD) sensor can reach up to 1000 Hz. Two efficient subpixel level motion extraction algorithms, namely the modified Taylor approximation refinement algorithm and the localization refinement algorithm, are integrated into the proposed vision sensor. Quantitative analysis shows that both of the two modified algorithms are at least five times faster than conventional upsampled cross-correlation approaches and achieve satisfactory error performance. The practicability of the developed sensor is evaluated by an experiment in a laboratory environment and a field test. Experimental results indicate that the developed high-speed vision-based sensor system can extract accurate dynamic structure vibration signals by tracking either artificial targets or natural features.

  7. Vision Voice: A Multimedia Exploration of Diabetes and Vision Loss in East Harlem.

    PubMed

    Ives, Brett; Nedelman, Michael; Redwood, Charysse; Ramos, Michelle A; Hughson-Andrade, Jessica; Hernandez, Evelyn; Jordan, Dioris; Horowitz, Carol R

    2015-01-01

    East Harlem, New York, is a community actively struggling with diabetes and its complications, including vision-related conditions that can affect many aspects of daily life. Vision Voice was a qualitative community-based participatory research (CBPR) study that intended to better understand the needs and experiences of people living with diabetes, other comorbid chronic illnesses, and vision loss in East Harlem. Using photovoice methodology, four participants took photographs, convened to review their photographs, and determined overarching themes for the group's collective body of work. Identified themes included effect of decreased vision function on personal independence/mobility and self-management of chronic conditions and the importance of informing community members and health care providers about these issues. The team next created a documentary film that further develops the narratives of the photovoice participants. The Vision Voice photovoice project was an effective tool to assess community needs, educate and raise awareness.

  8. Learning from vision-to-touch is different than learning from touch-to-vision.

    PubMed

    Wismeijer, Dagmar A; Gegenfurtner, Karl R; Drewing, Knut

    2012-01-01

    We studied whether vision can teach touch to the same extent as touch seems to teach vision. In a 2 × 2 between-participants learning study, we artificially correlated visual gloss cues with haptic compliance cues. In two "natural" tasks, we tested whether visual gloss estimations have an influence on haptic estimations of softness and vice versa. In two "novel" tasks, in which participants were either asked to haptically judge glossiness or to visually judge softness, we investigated how perceptual estimates transfer from one sense to the other. Our results showed that vision does not teach touch as efficient as touch seems to teach vision.

  9. Learning from vision-to-touch is different than learning from touch-to-vision

    PubMed Central

    Wismeijer, Dagmar A.; Gegenfurtner, Karl R.; Drewing, Knut

    2012-01-01

    We studied whether vision can teach touch to the same extent as touch seems to teach vision. In a 2 × 2 between-participants learning study, we artificially correlated visual gloss cues with haptic compliance cues. In two “natural” tasks, we tested whether visual gloss estimations have an influence on haptic estimations of softness and vice versa. In two “novel” tasks, in which participants were either asked to haptically judge glossiness or to visually judge softness, we investigated how perceptual estimates transfer from one sense to the other. Our results showed that vision does not teach touch as efficient as touch seems to teach vision. PMID:23181012

  10. Panoramic stereo sphere vision

    NASA Astrophysics Data System (ADS)

    Feng, Weijia; Zhang, Baofeng; Röning, Juha; Zong, Xiaoning; Yi, Tian

    2013-01-01

    Conventional stereo vision systems have a small field of view (FOV) which limits their usefulness for certain applications. While panorama vision is able to "see" in all directions of the observation space, scene depth information is missed because of the mapping from 3D reference coordinates to 2D panoramic image. In this paper, we present an innovative vision system which builds by a special combined fish-eye lenses module, and is capable of producing 3D coordinate information from the whole global observation space and acquiring no blind area 360°×360° panoramic image simultaneously just using single vision equipment with one time static shooting. It is called Panoramic Stereo Sphere Vision (PSSV). We proposed the geometric model, mathematic model and parameters calibration method in this paper. Specifically, video surveillance, robotic autonomous navigation, virtual reality, driving assistance, multiple maneuvering target tracking, automatic mapping of environments and attitude estimation are some of the applications which will benefit from PSSV.

  11. Operational Based Vision Assessment Automated Vision Test Collection User Guide

    DTIC Science & Technology

    2017-05-15

    repeatability to support correlation analysis. The AVT research grade tests also support interservice, international, industry, and academic partnerships...software, provides information concerning various menu options and operation of the test, and provides a brief description of each of the automated vision...2802, 6 Jun 2017. TABLE OF CONTENTS (concluded) Section Page 7.0 OBVA VISION TEST DESCRIPTIONS

  12. FPGA Vision Data Architecture

    NASA Technical Reports Server (NTRS)

    Morfopoulos, Arin C.; Pham, Thang D.

    2013-01-01

    JPL has produced a series of FPGA (field programmable gate array) vision algorithms that were written with custom interfaces to get data in and out of each vision module. Each module has unique requirements on the data interface, and further vision modules are continually being developed, each with their own custom interfaces. Each memory module had also been designed for direct access to memory or to another memory module.

  13. FLORA™: Phase I development of a functional vision assessment for prosthetic vision users.

    PubMed

    Geruschat, Duane R; Flax, Marshall; Tanna, Nilima; Bianchi, Michelle; Fisher, Andy; Goldschmidt, Mira; Fisher, Lynne; Dagnelie, Gislin; Deremeik, Jim; Smith, Audrey; Anaflous, Fatima; Dorn, Jessy

    2015-07-01

    Research groups and funding agencies need a functional assessment suitable for an ultra-low vision population to evaluate the impact of new vision-restoration treatments. The purpose of this study was to develop a pilot assessment to capture the functional visual ability and well-being of subjects whose vision has been partially restored with the Argus II Retinal Prosthesis System. The Functional Low-Vision Observer Rated Assessment (FLORA) pilot assessment involved a self-report section, a list of functional visual tasks for observation of performance and a case narrative summary. Results were analysed to determine whether the interview questions and functional visual tasks were appropriate for this ultra-low vision population and whether the ratings suffered from floor or ceiling effects. Thirty subjects with severe to profound retinitis pigmentosa (bare light perception or worse in both eyes) were enrolled in a clinical trial and implanted with the Argus II System. From this population, 26 subjects were assessed with the FLORA. Seven different evaluators administered the assessment. All 14 interview questions were asked. All 35 tasks for functional vision were selected for evaluation at least once, with an average of 20 subjects being evaluated for each test item. All four rating options—impossible (33 per cent), difficult (23 per cent), moderate (24 per cent) and easy (19 per cent)—were used by the evaluators. Evaluators also judged the amount of vision they observed the subjects using to complete the various tasks, with 'vision only' occurring 75 per cent on average with the System ON, and 29 per cent with the System OFF. The first version of the FLORA was found to contain useful elements for evaluation and to avoid floor and ceiling effects. The next phase of development will be to refine the assessment and to establish reliability and validity to increase its value as an assessment tool for functional vision and well-being. © 2015 The Authors. Clinical

  14. Developing Administrative Vision.

    ERIC Educational Resources Information Center

    Chance, Edward W.

    Visionary leadership has emerged as a significant characteristic of high performing school administrators. Vision provides a sense of direction for the school and facilitates accomplishment. Administrators must move from authoritarian and managerial modes of operation to proactive leadership, and maintain a focus on the vision through turmoil and…

  15. Vision Based Localization in Urban Environments

    NASA Technical Reports Server (NTRS)

    McHenry, Michael; Cheng, Yang; Matthies, Larry

    2005-01-01

    As part of DARPA's MARS2020 program, the Jet Propulsion Laboratory developed a vision-based system for localization in urban environments that requires neither GPS nor active sensors. System hardware consists of a pair of small FireWire cameras and a standard Pentium-based computer. The inputs to the software system consist of: 1) a crude grid-based map describing the positions of buildings, 2) an initial estimate of robot location and 3) the video streams produced by each camera. At each step during the traverse the system: captures new image data, finds image features hypothesized to lie on the outside of a building, computes the range to those features, determines an estimate of the robot's motion since the previous step and combines that data with the map to update a probabilistic representation of the robot's location. This probabilistic representation allows the system to simultaneously represent multiple possible locations, For our testing, we have derived the a priori map manually using non-orthorectified overhead imagery, although this process could be automated. The software system consists of two primary components. The first is the vision system which uses binocular stereo ranging together with a set of heuristics to identify features likely to be part of building exteriors and to compute an estimate of the robot's motion since the previous step. The resulting visual features and the associated range measurements are software component, a particle-filter based localization system. This system uses the map and the then fed to the second primary most recent results from the vision system to update the estimate of the robot's location. This report summarizes the design of both the hardware and software and will include the results of applying the system to the global localization of a robot over an approximately half-kilometer traverse across JPL'S Pasadena campus.

  16. Operation of a solid oxide fuel cell on biodiesel with a partial oxidation reformer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siefert, N, Shekhawat, D.; Gemmen, R.; Berry, D.

    The National Energy Technology Laboratory’s Office of Research & Development (NETL/ORD) has successfully demonstrated the operation of a solid oxide fuel cell (SOFC) using reformed biodiesel. The biodiesel for the project was produced and characterized by West Virginia State University (WVSU). This project had two main aspects: 1) demonstrate a catalyst formulation on monolith for biodiesel fuel reforming; and 2) establish SOFC stack test stand capabilities. Both aspects have been completed successfully. For the first aspect, in–house patented catalyst specifications were developed, fabricated and tested. Parametric reforming studies of biofuels provided data on fuel composition, catalyst degradation, syngas composition, andmore » operating parameters required for successful reforming and integration with the SOFC test stand. For the second aspect, a stack test fixture (STF) for standardized testing, developed by Pacific Northwest National Laboratory (PNNL) and Lawrence Berkeley National Laboratory (LBNL) for the Solid Energy Conversion Alliance (SECA) Program, was engineered and constructed at NETL. To facilitate the demonstration of the STF, NETL employed H.C. Starck Ceramics GmbH & Co. (Germany) anode supported solid oxide cells. In addition, anode supported cells, SS441 end plates, and cell frames were transferred from PNNL to NETL. The stack assembly and conditioning procedures, including stack welding and sealing, contact paste application, binder burn-out, seal-setting, hot standby, and other stack assembly and conditioning methods were transferred to NETL. In the future, fuel cell stacks provided by SECA or other developers could be tested at the STF to validate SOFC performance on various fuels. The STF operated on hydrogen for over 1000 hrs before switching over to reformed biodiesel for 100 hrs of operation. Combining these first two aspects led to demonstrating the biodiesel syngas in the STF. A reformer was built and used to convert 0.5 ml/min of

  17. A new color vision test to differentiate congenital and acquired color vision defects.

    PubMed

    Shin, Young Joo; Park, Kyu Hyung; Hwang, Jeong-Min; Wee, Won Ryang; Lee, Jin Hak

    2007-07-01

    To investigate the efficacy of a novel computer-controlled color test for the differentiation of congenital and acquired color vision deficiency. Observational cross-sectional study. Thirty-one patients with congenital color vision deficiency and 134 patients with acquired color vision deficiency with a Snellen visual acuity better than 20/30 underwent an ophthalmologic examination including the Ishihara color test, Hardy-Rand-Rittler test, Nagel anomaloscopy, and the Seohan computerized hue test between June, 2003, and January, 2004. To investigate the type of color vision defect, a graph of the Seohan computerized hue test was divided into 4 quadrants and error scores in each quadrant were summated. The ratio between the sums of error scores of quadrants I and III (Q1+Q3) and those of quadrants II and IV (Q2+Q4) was calculated. Error scores and ratio in quadrant analysis of the Seohan computerized hue test. The Seohan computerized hue test showed that the sum of Q2+Q4 was significantly higher than the sum of Q1+Q3 in congenital color vision deficiency (P<0.01, paired t test) and that the sum of Q2+Q4 was significantly lower than the sum of Q1+Q3 in acquired color vision deficiency (P<0.01, paired t test). In terms of discriminating congenital and acquired color vision deficiency, the ratio in quadrant analysis had 93.3% sensitivity and 98.5% specificity with a reference value of 1.5 by the Seohan computerized hue test (95% confidence interval). The quadrant analysis and ratio of (Q2+Q4)/(Q1+Q3) using the Seohan computerized hue test effectively differentiated congenital and acquired color vision deficiency.

  18. Why Vision 2020?

    ERIC Educational Resources Information Center

    Hinckley, June

    2000-01-01

    Discusses changes in technology, information, and people and the impact on music programs. The Vision 2020 project focuses on the future of music education. Addresses the events that created Vision 2020. Includes "The Housewright Declaration," a summarization of agreements from the Housewright Symposium on the Future of Music Education. (CMK)

  19. Dynamic Vision for Control

    DTIC Science & Technology

    2006-07-27

    unlimited 13. SUPPLEMENTARY NOTES 14. ABSTRACT The goal of this project was to develop analytical and computational tools to make vision a Viable sensor for...vision.ucla. edu July 27, 2006 Abstract The goal of this project was to develop analytical and computational tools to make vision a viable sensor for the ... sensors . We have proposed the framework of stereoscopic segmentation where multiple images of the same obejcts were jointly processed to extract geometry

  20. Stereo Vision Inside Tire

    DTIC Science & Technology

    2015-08-21

    using the Open Computer Vision ( OpenCV ) libraries [6] for computer vision and the Qt library [7] for the user interface. The software has the...depth. The software application calibrates the cameras using the plane based calibration model from the OpenCV calib3D module and allows the...6] OpenCV . 2015. OpenCV Open Source Computer Vision. [Online]. Available at: opencv.org [Accessed]: 09/01/2015. [7] Qt. 2015. Qt Project home

  1. Naval Aviation Vision Standards Research at the Naval Aerospace Medical Research Laboratory: The Long View.

    DTIC Science & Technology

    1993-04-01

    standards of personnel selection and retention that have been validated by a demonstrated relationship to succesful aviation performance. Current vision...manner in which the measurements were made. It is really quite meaningless to think of the measured correlation as indicative of some "true" correlation...of people are myopic or near-sighted in the dark. The measurement of dark focus is shown on the abscissa in Fig. 5. Negative values indicate a myopic

  2. Development of the method of aggregation to determine the current storage area using computer vision and radiofrequency identification

    NASA Astrophysics Data System (ADS)

    Astafiev, A.; Orlov, A.; Privezencev, D.

    2018-01-01

    The article is devoted to the development of technology and software for the construction of positioning and control systems in industrial plants based on aggregation to determine the current storage area using computer vision and radiofrequency identification. It describes the developed of the project of hardware for industrial products positioning system in the territory of a plant on the basis of radio-frequency grid. It describes the development of the project of hardware for industrial products positioning system in the plant on the basis of computer vision methods. It describes the development of the method of aggregation to determine the current storage area using computer vision and radiofrequency identification. Experimental studies in laboratory and production conditions have been conducted and described in the article.

  3. Machine vision for digital microfluidics

    NASA Astrophysics Data System (ADS)

    Shin, Yong-Jun; Lee, Jeong-Bong

    2010-01-01

    Machine vision is widely used in an industrial environment today. It can perform various tasks, such as inspecting and controlling production processes, that may require humanlike intelligence. The importance of imaging technology for biological research or medical diagnosis is greater than ever. For example, fluorescent reporter imaging enables scientists to study the dynamics of gene networks with high spatial and temporal resolution. Such high-throughput imaging is increasingly demanding the use of machine vision for real-time analysis and control. Digital microfluidics is a relatively new technology with expectations of becoming a true lab-on-a-chip platform. Utilizing digital microfluidics, only small amounts of biological samples are required and the experimental procedures can be automatically controlled. There is a strong need for the development of a digital microfluidics system integrated with machine vision for innovative biological research today. In this paper, we show how machine vision can be applied to digital microfluidics by demonstrating two applications: machine vision-based measurement of the kinetics of biomolecular interactions and machine vision-based droplet motion control. It is expected that digital microfluidics-based machine vision system will add intelligence and automation to high-throughput biological imaging in the future.

  4. Understanding and preventing computer vision syndrome.

    PubMed

    Loh, Ky; Redd, Sc

    2008-01-01

    The invention of computer and advancement in information technology has revolutionized and benefited the society but at the same time has caused symptoms related to its usage such as ocular sprain, irritation, redness, dryness, blurred vision and double vision. This cluster of symptoms is known as computer vision syndrome which is characterized by the visual symptoms which result from interaction with computer display or its environment. Three major mechanisms that lead to computer vision syndrome are extraocular mechanism, accommodative mechanism and ocular surface mechanism. The visual effects of the computer such as brightness, resolution, glare and quality all are known factors that contribute to computer vision syndrome. Prevention is the most important strategy in managing computer vision syndrome. Modification in the ergonomics of the working environment, patient education and proper eye care are crucial in managing computer vision syndrome.

  5. Predictors of vision impairment in Multiple Sclerosis.

    PubMed

    Sanchez-Dalmau, Bernardo; Martinez-Lapiscina, Elena H; Pulido-Valdeolivas, Irene; Zubizarreta, Irati; Llufriu, Sara; Blanco, Yolanda; Sola-Valls, Nuria; Sepulveda, Maria; Guerrero, Ana; Alba, Salut; Andorra, Magi; Camos, Anna; Sanchez-Vela, Laura; Alfonso, Veronica; Saiz, Albert; Villoslada, Pablo

    2018-01-01

    Visual impairment significantly alters the quality of life of people with Multiple Sclerosis (MS). The objective of this study was to identify predictors (independent variables) of visual outcomes, and to define their relationship with neurological disability and retinal atrophy when assessed by optical coherence tomography (OCT). We performed a cross-sectional analysis of 119 consecutive patients with MS, assessing vision using high contrast visual acuity (LogMar), 2.5% and 1.25% low contrast visual acuity (Sloan charts), and color vision (Hardy-Rand-Rittler plates). Quality of vision is a patient reported outcome based on an individual's unique perception of his or her vision and was assessed with the Visual Functioning Questionnaire-25 (VFQ-25) with the 10 neuro-ophthalmologic items. MS disability was assessed using the expanded disability status scale (EDSS), the MS functional composite (MSFC) and the brief repetitive battery-neuropsychology (BRB-N). Retinal atrophy was assessed using spectral domain OCT, measuring the thickness of the peripapillar retinal nerve fiber layer (pRNFL) and the volume of the ganglion cell plus inner plexiform layer (GCIPL). The vision of patients with MS was impaired, particularly in eyes with prior optic neuritis. Retinal atrophy (pRNFL and GCIPL) was closely associated with impaired low contrast vision and color vision, whereas the volume of the GCIPL showed a trend (p = 0.092) to be associated with quality of vision. Multiple regression analysis revealed that EDSS was an explanatory variable for high contrast vision after stepwise analysis, GCIPL volume for low contrast vision, and GCIPL volume and EDSS for color vision. The explanatory variables for quality of vision were high contrast vision and color vision. In summary, quality of vision in MS depends on the impairment of high contrast visual acuity and color vision due to the disease.

  6. Superintendent Leadership and Districtwide Vision.

    ERIC Educational Resources Information Center

    Lilly, Edward R.

    The concept of superintendent "vision" as a key element of effective leadership is discussed in this paper, which develops a framework for understanding the creation of vision, its implementation and articulation, and organizational impact. Vision differs from strategy in that it represents a set of beliefs about the school district's aspiring…

  7. Sandia National Laboratories focus issue: introduction.

    PubMed

    Boye, Robert

    2014-08-20

    For more than six decades, Sandia has provided the critical science and technology to address the nation's most challenging issues. Our original nuclear weapons mission has been complemented with work in defense systems, energy and climate, as well as international and homeland security. Our vision is to be a premier science and engineering laboratory for technology solutions to the most challenging problems that threaten peace and freedom for our nation and the globe.

  8. Vision Screening For Head Starters.

    ERIC Educational Resources Information Center

    Foley, Celia

    To determine which children in the Head Start program may have vision problems, Head Start teachers and staff do vision "screening." This booklet demonstrates how to do the screening using the Snellen "E Chart." Trouble signs that the test administrator should be aware of are listed, and vision scores are explained simply.…

  9. Reading Digital with Low Vision

    PubMed Central

    Legge, Gordon E.

    2017-01-01

    Reading difficulty is a major consequence of vision loss for more than four million Americans with low vision. Difficulty in accessing print imposes obstacles to education, employment, social interaction and recreation. In recent years, research in vision science has made major strides in understanding the impact of low vision on reading, and the dependence of reading performance on text properties. The ongoing transition to the production and distribution of digital documents brings about new opportunities for people with visual impairment. Digital documents on computers and mobile devices permit customization of print size, spacing, font style, contrast polarity and page layout to optimize reading displays for people with low vision. As a result, we now have unprecedented opportunities to adapt text format to meet the needs of visually impaired readers. PMID:29242668

  10. Application of machine vision to pup loaf bread evaluation

    NASA Astrophysics Data System (ADS)

    Zayas, Inna Y.; Chung, O. K.

    1996-12-01

    Intrinsic end-use quality of hard winter wheat breeding lines is routinely evaluated at the USDA, ARS, USGMRL, Hard Winter Wheat Quality Laboratory. Experimental baking test of pup loaves is the ultimate test for evaluating hard wheat quality. Computer vision was applied to developing an objective methodology for bread quality evaluation for the 1994 and 1995 crop wheat breeding line samples. Computer extracted features for bread crumb grain were studied, using subimages (32 by 32 pixel) and features computed for the slices with different threshold settings. A subsampling grid was located with respect to the axis of symmetry of a slice to provide identical topological subimage information. Different ranking techniques were applied to the databases. Statistical analysis was run on the database with digital image and breadmaking features. Several ranking algorithms and data visualization techniques were employed to create a sensitive scale for porosity patterns of bread crumb. There were significant linear correlations between machine vision extracted features and breadmaking parameters. Crumb grain scores by human experts were correlated more highly with some image features than with breadmaking parameters.

  11. Vision Impairment and Blindness

    MedlinePlus

    ... books can make life easier. There are also devices to help those with no vision, like text-reading software and braille books. The sooner vision loss or eye disease is found and treated, the greater your ...

  12. Evolution of colour vision in mammals.

    PubMed

    Jacobs, Gerald H

    2009-10-12

    Colour vision allows animals to reliably distinguish differences in the distributions of spectral energies reaching the eye. Although not universal, a capacity for colour vision is sufficiently widespread across the animal kingdom to provide prima facie evidence of its importance as a tool for analysing and interpreting the visual environment. The basic biological mechanisms on which vertebrate colour vision ultimately rests, the cone opsin genes and the photopigments they specify, are highly conserved. Within that constraint, however, the utilization of these basic elements varies in striking ways in that they appear, disappear and emerge in altered form during the course of evolution. These changes, along with other alterations in the visual system, have led to profound variations in the nature and salience of colour vision among the vertebrates. This article concerns the evolution of colour vision among the mammals, viewing that process in the context of relevant biological mechanisms, of variations in mammalian colour vision, and of the utility of colour vision.

  13. Evolution of colour vision in mammals

    PubMed Central

    Jacobs, Gerald H.

    2009-01-01

    Colour vision allows animals to reliably distinguish differences in the distributions of spectral energies reaching the eye. Although not universal, a capacity for colour vision is sufficiently widespread across the animal kingdom to provide prima facie evidence of its importance as a tool for analysing and interpreting the visual environment. The basic biological mechanisms on which vertebrate colour vision ultimately rests, the cone opsin genes and the photopigments they specify, are highly conserved. Within that constraint, however, the utilization of these basic elements varies in striking ways in that they appear, disappear and emerge in altered form during the course of evolution. These changes, along with other alterations in the visual system, have led to profound variations in the nature and salience of colour vision among the vertebrates. This article concerns the evolution of colour vision among the mammals, viewing that process in the context of relevant biological mechanisms, of variations in mammalian colour vision, and of the utility of colour vision. PMID:19720656

  14. An Inquiry-Based Vision Science Activity for Graduate Students and Postdoctoral Research Scientists

    NASA Astrophysics Data System (ADS)

    Putnam, N. M.; Maness, H. L.; Rossi, E. A.; Hunter, J. J.

    2010-12-01

    The vision science activity was originally designed for the 2007 Center for Adaptive Optics (CfAO) Summer School. Participants were graduate students, postdoctoral researchers, and professionals studying the basics of adaptive optics. The majority were working in fields outside vision science, mainly astronomy and engineering. The primary goal of the activity was to give participants first-hand experience with the use of a wavefront sensor designed for clinical measurement of the aberrations of the human eye and to demonstrate how the resulting wavefront data generated from these measurements can be used to assess optical quality. A secondary goal was to examine the role wavefront measurements play in the investigation of vision-related scientific questions. In 2008, the activity was expanded to include a new section emphasizing defocus and astigmatism and vision testing/correction in a broad sense. As many of the participants were future post-secondary educators, a final goal of the activity was to highlight the inquiry-based approach as a distinct and effective alternative to traditional laboratory exercises. Participants worked in groups throughout the activity and formative assessment by a facilitator (instructor) was used to ensure that participants made progress toward the content goals. At the close of the activity, participants gave short presentations about their work to the whole group, the major points of which were referenced in a facilitator-led synthesis lecture. We discuss highlights and limitations of the vision science activity in its current format (2008 and 2009 summer schools) and make recommendations for its improvement and adaptation to different audiences.

  15. The Pedagogy of Teaching Educational Vision: A Vision Coach's Field Notes about Leaders as Learners

    ERIC Educational Resources Information Center

    Schein, Jeffrey

    2009-01-01

    The emerging field of educational visioning is full of challenges and phenomena worthy of careful analysis and documentation. A relatively neglected phenomenon is the learning curve of the leaders (often lay leaders) involved in the visioning process. This article documents a range of experiences of the author serving as a vision coach to five…

  16. Low vision and mobility scooters: the experiences of individuals with low vision who use mobility scooters.

    PubMed

    McMullan, Keri S; Butler, Mary

    2018-05-09

    Older adults with low vision are a growing population with rehabilitation needs including support with community mobility to enable community participation. Some older adults with low vision choose to use mobility scooters to mobilize within their community, but there is limited research about the use by people with low vision. This paper describes a pilot study and asks the question: what are the experiences of persons with low vision who use mobility scooters? This study gathered the experiences of four participants with low vision, aged 51 and over, who regularly use mobility scooters. Diverse methods were used including a go-along, a semi-structured interview and a new measure of functional vision for mobility called the vision-related outcomes in orientation and mobility (VROOM). Four themes were found to describe experiences: autonomy and well-being, accessibility, community interactions and self-regulation. Discussion and implications: This study was a pilot for a larger study examining self-regulation in scooter users. However, as roles emerge for health professionals and scooters, the findings also provide evidence to inform practice, because it demonstrates the complex meaning and influences on performance involved in low vision mobility scooter use. Implications for rehabilitation Scooter use supports autonomy and well-being and community connections for individuals with both mobility and visual impairments. Low vision scooter users demonstrate self-regulation of their scooter use to manage both their visual and environmental limitations. Issues of accessibility experienced by this sample affect a wider community of footpath users, emphasizing the need for councils to address inadequate infrastructure. Rehabilitators can support their low vision clients' scooter use by acknowledging issues of accessibility and promoting self-regulation strategies to manage risks and barriers.

  17. Stereo vision and strabismus

    PubMed Central

    Read, J C A

    2015-01-01

    Binocular stereopsis, or stereo vision, is the ability to derive information about how far away objects are, based solely on the relative positions of the object in the two eyes. It depends on both sensory and motor abilities. In this review, I briefly outline some of the neuronal mechanisms supporting stereo vision, and discuss how these are disrupted in strabismus. I explain, in some detail, current methods of assessing stereo vision and their pros and cons. Finally, I review the evidence supporting the clinical importance of such measurements. PMID:25475234

  18. Clinical colour vision tests.

    PubMed

    Dain, Stephen J

    2004-07-01

    The structure and function of the available and significant clinical colour vision tests are reviewed in the light of the needs in the clinical examination of congenital and acquired colour vision deficiencies. The tests are grouped and described as pseudo-isochromatic plates, arrangement tests, matching tests and vocational tests. The colorimetric constructions of the test types are described and the efficiency of their performance and usefulness discussed. Recommendations are made for basic and extended test batteries, when examining of congenital and acquired colour vision deficiencies in the consulting room.

  19. Case Report: Use of Sports and Performance Vision Training to Benefit a Low-vision Patient's Function.

    PubMed

    Laby, Daniel M

    2018-05-17

    Despite our inability to attenuate the course of many ocular diseases that can ultimately lead to loss or significantly decreased visual function, this report describes a potential technique to aid such patients in maximizing the use of the vision that remains. The aim of this study was to demonstrate the applicability of utilizing sports vision training to improve objective and subjective visuomotor function in a low-vision patient. A 37-year-old woman with Usher syndrome presented with reduced central visual acuity and visual field. Although we were unable to reverse the damage resulting from her diagnosis, we were able to improve the use of the remaining vision. A 27 to 31% improvement in hand-eye coordination was achieved along with a 41% improvement in object tracking and visual concentration. Most importantly, following the 14-week training period, there was also a subjective improvement in the patient's appreciation of her visual ability. The sports vision literature cites many examples in which sports vision training is useful in improving visuomotor and on-field performance. We hypothesized that these techniques may be used to aid not only athletes but also patients with low vision. Despite suffering from reduced acuity and a limited visual field, these patients often still have a significant amount of vision ability that can be used to guide motor actions. Using techniques to increase the efficient use of this remaining vision may reduce the impact of the reduced visual function and aid in activities of daily living.

  20. Vision-based guidance for an automated roving vehicle

    NASA Technical Reports Server (NTRS)

    Griffin, M. D.; Cunningham, R. T.; Eskenazi, R.

    1978-01-01

    A controller designed to guide an automated vehicle to a specified target without external intervention is described. The intended application is to the requirements of planetary exploration, where substantial autonomy is required because of the prohibitive time lags associated with closed-loop ground control. The guidance algorithm consists of a set of piecewise-linear control laws for velocity and steering commands, and is executable in real time with fixed-point arithmetic. The use of a previously-reported object tracking algorithm for the vision system to provide position feedback data is described. Test results of the control system on a breadboard rover at the Jet Propulsion Laboratory are included.

  1. What aspects of vision facilitate haptic processing?

    PubMed

    Millar, Susanna; Al-Attar, Zainab

    2005-12-01

    We investigate how vision affects haptic performance when task-relevant visual cues are reduced or excluded. The task was to remember the spatial location of six landmarks that were explored by touch in a tactile map. Here, we use specially designed spectacles that simulate residual peripheral vision, tunnel vision, diffuse light perception, and total blindness. Results for target locations differed, suggesting additional effects from adjacent touch cues. These are discussed. Touch with full vision was most accurate, as expected. Peripheral and tunnel vision, which reduce visuo-spatial cues, differed in error pattern. Both were less accurate than full vision, and significantly more accurate than touch with diffuse light perception, and touch alone. The important finding was that touch with diffuse light perception, which excludes spatial cues, did not differ from touch without vision in performance accuracy, nor in location error pattern. The contrast between spatially relevant versus spatially irrelevant vision provides new, rather decisive, evidence against the hypothesis that vision affects haptic processing even if it does not add task-relevant information. The results support optimal integration theories, and suggest that spatial and non-spatial aspects of vision need explicit distinction in bimodal studies and theories of spatial integration.

  2. 2016-2017 Status Assessment and Update on the Wind Vision Roadmap: Findings from Topical Working Sessions, April 2016 - March 2017

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lantz, Eric J.; Mone, Christopher D.; DeMeo, Edgar

    IIn March 2015, the U.S. Department of Energy (DOE) released Wind Vision: A New Era for Wind Power in the United States (DOE 2015), which explores a scenario in which wind provides 10 percent of U.S. electricity in 2020, 20 percent in 2030, and 35 percent in 2050. The Wind Vision report also includes a roadmap of recommended actions aimed at pursuit of the vision and its underlying wind-deployment scenario. The roadmap was compiled by the Wind Vision project team, which included representatives from the industrial, electric-power, government-laboratory, academic, environmental-stewardship, regulatory, and permitting stakeholder groups. The roadmap describes high-level activitiesmore » suitable for all sectors with a stake in wind power and energy development. It is intended to be a 'living document,' and DOE expects to engage the wind community from time to time to track progress.« less

  3. Vision

    NASA Technical Reports Server (NTRS)

    Taylor, J. H.

    1973-01-01

    Some data on human vision, important in present and projected space activities, are presented. Visual environment and performance and structure of the visual system are also considered. Visual perception during stress is included.

  4. Wind Vision: A New Era for Wind Power in the United States (Highlights); U.S. Department of Energy (DOE), NREL (National Renewable Energy Laboratory)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2015-03-01

    This is a four-part Wind Vision project, consisting of Wind Vision Highlights, Executive Summary, a Full Report, and Appendix. The U.S. Department of Energy (DOE) Wind Program, in close cooperation with the wind industry, led a comprehensive analysis to evaluate future pathways for the wind industry. The Wind Vision report updates and expands upon the DOE's 2008 report, 20% Wind Energy by 2030, and defines the societal, environmental, and economic benefits of wind power in a scenario with wind energy supplying 10% of national end-use electricity demand by 2020, 20% by 2030, and 35% by 2050.

  5. OH Vision Test

    NASA Image and Video Library

    2014-06-03

    ISS040-E-006739 (3 June 2014) --- European Space Agency astronaut Alexander Gerst, Expedition 40 flight engineer, uses the Optical Coherence Tomography (OCT) camera during an Ocular Health (OH) vision test in the Harmony node of the International Space Station. The OH experiment observes and seeks to understand vision changes during long-term space missions. NASA astronaut Steve Swanson (left), Expedition 40 commander, assists Gerst.

  6. Geomechanical Modeling of CO2 Injection Site to Predict Wellbore Stresses and Strains for the Design of Wellbore Seal Repair Materials

    NASA Astrophysics Data System (ADS)

    Sobolik, S. R.; Gomez, S. P.; Matteo, E. N.; Stormont, J.

    2014-12-01

    This paper will present the results of large-scale three-dimensional calculations simulating the hydrological-mechanical behavior of a CO2injection reservoir and the resulting effects on wellbore casings and sealant repair materials. A critical aspect of designing effective wellbore seal repair materials is predicting thermo-mechanical perturbations in local stress that can compromise seal integrity. The DOE-NETL project "Wellbore Seal Repair Using Nanocomposite Materials," is interested in the stress-strain history of abandoned wells, as well as changes in local pressure, stress, and temperature conditions that accompany carbon dioxide injection or brine extraction. Two distinct computational models comprise the current modeling effort. The first is a field scale model that uses the stratigraphy, material properties, and injection history from a pilot CO2injection operation in Cranfield, MS to develop a stress-strain history for wellbore locations from 100 to 400 meters from an injection well. The results from the field scale model are used as input to a more detailed model of a wellbore casing. The 3D wellbore model examines the impacts of various loading scenarios on a casing structure. This model has been developed in conjunction with bench-top experiments of an integrated seal system in an idealized scaled wellbore mock-up being used to test candidate seal repair materials. The results from these models will be used to estimate the necessary mechanical properties needed for a successful repair material. This material is based upon work supported by the US Department of Energy (DOE) National Energy Technology Laboratory (NETL) under Grant Number DE-FE0009562. This project is managed and administered by the Storage Division of the NETL and funded by DOE/NETL and cost-sharing partners. This work was funded in part by the Center for Frontiers of Subsurface Energy Security, an Energy Frontier Research Center funded by the US Department of Energy, Office of Science

  7. Geomechanical Modeling of CO2 Injection Site to Predict Wellbore Stresses and Strains for the Design of Wellbore Seal Repair Materials

    NASA Astrophysics Data System (ADS)

    Sobolik, S. R.; Gomez, S. P.; Matteo, E. N.; Stormont, J.

    2015-12-01

    This paper will present the results of large-scale three-dimensional calculations simulating the hydrological-mechanical behavior of a CO2injection reservoir and the resulting effects on wellbore casings and sealant repair materials. A critical aspect of designing effective wellbore seal repair materials is predicting thermo-mechanical perturbations in local stress that can compromise seal integrity. The DOE-NETL project "Wellbore Seal Repair Using Nanocomposite Materials," is interested in the stress-strain history of abandoned wells, as well as changes in local pressure, stress, and temperature conditions that accompany carbon dioxide injection or brine extraction. Two distinct computational models comprise the current modeling effort. The first is a field scale model that uses the stratigraphy, material properties, and injection history from a pilot CO2injection operation in Cranfield, MS to develop a stress-strain history for wellbore locations from 100 to 400 meters from an injection well. The results from the field scale model are used as input to a more detailed model of a wellbore casing. The 3D wellbore model examines the impacts of various loading scenarios on a casing structure. This model has been developed in conjunction with bench-top experiments of an integrated seal system in an idealized scaled wellbore mock-up being used to test candidate seal repair materials. The results from these models will be used to estimate the necessary mechanical properties needed for a successful repair material. This material is based upon work supported by the US Department of Energy (DOE) National Energy Technology Laboratory (NETL) under Grant Number DE-FE0009562. This project is managed and administered by the Storage Division of the NETL and funded by DOE/NETL and cost-sharing partners. This work was funded in part by the Center for Frontiers of Subsurface Energy Security, an Energy Frontier Research Center funded by the US Department of Energy, Office of Science

  8. Report: Unsupervised identification of malaria parasites using computer vision.

    PubMed

    Khan, Najeed Ahmed; Pervaz, Hassan; Latif, Arsalan; Musharaff, Ayesha

    2017-01-01

    Malaria in human is a serious and fatal tropical disease. This disease results from Anopheles mosquitoes that are infected by Plasmodium species. The clinical diagnosis of malaria based on the history, symptoms and clinical findings must always be confirmed by laboratory diagnosis. Laboratory diagnosis of malaria involves identification of malaria parasite or its antigen / products in the blood of the patient. Manual diagnosis of malaria parasite by the pathologists has proven to become cumbersome. Therefore, there is a need of automatic, efficient and accurate identification of malaria parasite. In this paper, we proposed a computer vision based approach to identify the malaria parasite from light microscopy images. This research deals with the challenges involved in the automatic detection of malaria parasite tissues. Our proposed method is based on the pixel-based approach. We used K-means clustering (unsupervised approach) for the segmentation to identify malaria parasite tissues.

  9. Computer vision syndrome: a review.

    PubMed

    Blehm, Clayton; Vishnu, Seema; Khattak, Ashbala; Mitra, Shrabanee; Yee, Richard W

    2005-01-01

    As computers become part of our everyday life, more and more people are experiencing a variety of ocular symptoms related to computer use. These include eyestrain, tired eyes, irritation, redness, blurred vision, and double vision, collectively referred to as computer vision syndrome. This article describes both the characteristics and treatment modalities that are available at this time. Computer vision syndrome symptoms may be the cause of ocular (ocular-surface abnormalities or accommodative spasms) and/or extraocular (ergonomic) etiologies. However, the major contributor to computer vision syndrome symptoms by far appears to be dry eye. The visual effects of various display characteristics such as lighting, glare, display quality, refresh rates, and radiation are also discussed. Treatment requires a multidirectional approach combining ocular therapy with adjustment of the workstation. Proper lighting, anti-glare filters, ergonomic positioning of computer monitor and regular work breaks may help improve visual comfort. Lubricating eye drops and special computer glasses help relieve ocular surface-related symptoms. More work needs to be done to specifically define the processes that cause computer vision syndrome and to develop and improve effective treatments that successfully address these causes.

  10. Virtual Vision

    NASA Astrophysics Data System (ADS)

    Terzopoulos, Demetri; Qureshi, Faisal Z.

    Computer vision and sensor networks researchers are increasingly motivated to investigate complex multi-camera sensing and control issues that arise in the automatic visual surveillance of extensive, highly populated public spaces such as airports and train stations. However, they often encounter serious impediments to deploying and experimenting with large-scale physical camera networks in such real-world environments. We propose an alternative approach called "Virtual Vision", which facilitates this type of research through the virtual reality simulation of populated urban spaces, camera sensor networks, and computer vision on commodity computers. We demonstrate the usefulness of our approach by developing two highly automated surveillance systems comprising passive and active pan/tilt/zoom cameras that are deployed in a virtual train station environment populated by autonomous, lifelike virtual pedestrians. The easily reconfigurable virtual cameras distributed in this environment generate synthetic video feeds that emulate those acquired by real surveillance cameras monitoring public spaces. The novel multi-camera control strategies that we describe enable the cameras to collaborate in persistently observing pedestrians of interest and in acquiring close-up videos of pedestrians in designated areas.

  11. [Comparison of the Pressure on the Larynx and Tongue Using McGRATH® MAC Video Laryngoscope--Direct Vision versus Indirect Vision].

    PubMed

    Tanaka, Yasutomo; Miyazaki, Yukiko; Kitakata, Hidenori; Shibuya, Hiromi; Okada, Toshiki

    2015-12-01

    Studies show that McGRATH® MAC (McG) is useful during direct laryngoscopy. However, no study has examined whether McG re- duces pressure on the upper airway tract We compared direct vision with indirect vision concerning pressure on the larynx and tongue. Twenty two anesthesiologists and 16 junior residents attempted direct laryngoscopy of airway management simulator using McG with direct vision and indirect vision. Pressure was measured using pressure measurement film. In anesthesiologists group, pressure on larynx was 14.8 ± 2.7 kgf · cm(-2) with direct vision and 12.7 ± 2.7 kgf · cm(-2) with indirect vision (P < 0.05). Pressure on the tongue was 8.8 ± 3.2 kgf cm(-2) with direct vision and 7.6 ± 2.8 kgf · cm(-2) with indirect vision (P = 0.18). In junior residents group, pressure on larynx was 19.0 ± 1.3 kgf · cm(-2) with direct vision and 14.1 ± 3.1 kgf · cm(-2) with indirect vision (P < 0.05). Pressure on the tongue was 15.4 ± 3.6 kgf · cm(-2) with direct vision and 11.2 ± 4.7 kgf · cm(-2) with indirect vision (P < 0.05). McG with indirect vision can reduce pressure on the upper airway tract.

  12. Color Vision in Aniridia.

    PubMed

    Pedersen, Hilde R; Hagen, Lene A; Landsend, Erlend C S; Gilson, Stuart J; Utheim, Øygunn A; Utheim, Tor P; Neitz, Maureen; Baraas, Rigmor C

    2018-04-01

    To assess color vision and its association with retinal structure in persons with congenital aniridia. We included 36 persons with congenital aniridia (10-66 years), and 52 healthy, normal trichromatic controls (10-74 years) in the study. Color vision was assessed with Hardy-Rand-Rittler (HRR) pseudo-isochromatic plates (4th ed., 2002); Cambridge Color Test and a low-vision version of the Color Assessment and Diagnosis test (CAD-LV). Cone-opsin genes were analyzed to confirm normal versus congenital color vision deficiencies. Visual acuity and ocular media opacities were assessed. The central 30° of both eyes were imaged with the Heidelberg Spectralis OCT2 to grade the severity of foveal hypoplasia (FH, normal to complete: 0-4). Five participants with aniridia had cone opsin genes conferring deutan color vision deficiency and were excluded from further analysis. Of the 31 with aniridia and normal opsin genes, 11 made two or more red-green (RG) errors on HRR, four of whom also made yellow-blue (YB) errors; one made YB errors only. A total of 19 participants had higher CAD-LV RG thresholds, of which eight also had higher CAD-LV YB thresholds, than normal controls. In aniridia, the thresholds were higher along the RG than the YB axis, and those with a complete FH had significantly higher RG thresholds than those with mild FH (P = 0.038). Additional increase in YB threshold was associated with secondary ocular pathology. Arrested foveal formation and associated alterations in retinal processing are likely to be the primary reason for impaired red-green color vision in aniridia.

  13. Theory underlying the peripheral vision horizon device

    NASA Technical Reports Server (NTRS)

    Money, K. E.

    1984-01-01

    Peripheral Vision Horizon Device (PVHD) theory states that the likelihood of pilot disorientation in flight is reduced by providing an artificial horizon that provides orientation information to peripheral vision. In considering the validity of the theory, three areas are explored: the use of an artificial horizon device over some other flight instrument; the use of peripheral vision over foveal vision; and the evidence that peripheral vision is well suited to the processing of orientation information.

  14. Synthetic Vision Systems

    NASA Technical Reports Server (NTRS)

    Prinzel, L.J.; Kramer, L.J.

    2009-01-01

    A synthetic vision system is an aircraft cockpit display technology that presents the visual environment external to the aircraft using computer-generated imagery in a manner analogous to how it would appear to the pilot if forward visibility were not restricted. The purpose of this chapter is to review the state of synthetic vision systems, and discuss selected human factors issues that should be considered when designing such displays.

  15. 3D vision system assessment

    NASA Astrophysics Data System (ADS)

    Pezzaniti, J. Larry; Edmondson, Richard; Vaden, Justin; Hyatt, Bryan; Chenault, David B.; Kingston, David; Geulen, Vanilynmae; Newell, Scott; Pettijohn, Brad

    2009-02-01

    In this paper, we report on the development of a 3D vision system consisting of a flat panel stereoscopic display and auto-converging stereo camera and an assessment of the system's use for robotic driving, manipulation, and surveillance operations. The 3D vision system was integrated onto a Talon Robot and Operator Control Unit (OCU) such that direct comparisons of the performance of a number of test subjects using 2D and 3D vision systems were possible. A number of representative scenarios were developed to determine which tasks benefited most from the added depth perception and to understand when the 3D vision system hindered understanding of the scene. Two tests were conducted at Fort Leonard Wood, MO with noncommissioned officers ranked Staff Sergeant and Sergeant First Class. The scenarios; the test planning, approach and protocols; the data analysis; and the resulting performance assessment of the 3D vision system are reported.

  16. Validation of vision-based obstacle detection algorithms for low-altitude helicopter flight

    NASA Technical Reports Server (NTRS)

    Suorsa, Raymond; Sridhar, Banavar

    1991-01-01

    A validation facility being used at the NASA Ames Research Center is described which is aimed at testing vision based obstacle detection and range estimation algorithms suitable for low level helicopter flight. The facility is capable of processing hundreds of frames of calibrated multicamera 6 degree-of-freedom motion image sequencies, generating calibrated multicamera laboratory images using convenient window-based software, and viewing range estimation results from different algorithms along with truth data using powerful window-based visualization software.

  17. Emergence of a utopian vision of modernist and futuristic houses and cities in early 20th century

    NASA Astrophysics Data System (ADS)

    Ma, Nan

    2017-04-01

    Throughout the development of literature on urban design theories, utopian thinking has played a crucial role as utopians were among the first designers. Many unrealized utopian projects such as The Radiant City, have presented a research laboratory and positive attempts for all architects, urban designers and theorists. In this essay, a utopian vision following under More’s and Jameson’s definitions is discussed, examining how the utopian vision of modernist and futuristic houses and cities emerged in the early twentieth century in response to several factors, what urban utopia aimed to represent, and how such version was represented in the built form and the urban landscapes.

  18. Development and evaluation of vision rehabilitation devices.

    PubMed

    Luo, Gang; Peli, Eli

    2011-01-01

    We have developed a range of vision rehabilitation devices and techniques for people with impaired vision due to either central vision loss or severely restricted peripheral visual field. We have conducted evaluation studies with patients to test the utilities of these techniques in an effort to document their advantages as well as their limitations. Here we describe our work on a visual field expander based on a head mounted display (HMD) for tunnel vision, a vision enhancement device for central vision loss, and a frequency domain JPEG/MPEG based image enhancement technique. All the evaluation studies included visual search paradigms that are suitable for conducting indoor controllable experiments.

  19. Gait disorder rehabilitation using vision and non-vision based sensors: A systematic review

    PubMed Central

    Ali, Asraf; Sundaraj, Kenneth; Ahmad, Badlishah; Ahamed, Nizam; Islam, Anamul

    2012-01-01

    Even though the amount of rehabilitation guidelines has never been greater, uncertainty continues to arise regarding the efficiency and effectiveness of the rehabilitation of gait disorders. This question has been hindered by the lack of information on accurate measurements of gait disorders. Thus, this article reviews the rehabilitation systems for gait disorder using vision and non-vision sensor technologies, as well as the combination of these. All papers published in the English language between 1990 and June, 2012 that had the phrases “gait disorder” “rehabilitation”, “vision sensor”, or “non vision sensor” in the title, abstract, or keywords were identified from the SpringerLink, ELSEVIER, PubMed, and IEEE databases. Some synonyms of these phrases and the logical words “and” “or” and “not” were also used in the article searching procedure. Out of the 91 published articles found, this review identified 84 articles that described the rehabilitation of gait disorders using different types of sensor technologies. This literature set presented strong evidence for the development of rehabilitation systems using a markerless vision-based sensor technology. We therefore believe that the information contained in this review paper will assist the progress of the development of rehabilitation systems for human gait disorders. PMID:22938548

  20. Unsold is unseen … or is it? Examining the role of peripheral vision in the consumer choice process using eye-tracking methodology.

    PubMed

    Wästlund, Erik; Shams, Poja; Otterbring, Tobias

    2018-01-01

    In visual marketing, the truism that "unseen is unsold" means that products that are not noticed will not be sold. This truism rests on the idea that the consumer choice process is heavily influenced by visual search. However, given that the majority of available products are not seen by consumers, this article examines the role of peripheral vision in guiding attention during the consumer choice process. In two eye-tracking studies, one conducted in a lab facility and the other conducted in a supermarket, the authors investigate the role and limitations of peripheral vision. The results show that peripheral vision is used to direct visual attention when discriminating between target and non-target objects in an eye-tracking laboratory. Target and non-target similarity, as well as visual saliency of non-targets, constitute the boundary conditions for this effect, which generalizes from instruction-based laboratory tasks to preference-based choice tasks in a real supermarket setting. Thus, peripheral vision helps customers to devote a larger share of attention to relevant products during the consumer choice process. Taken together, the results show how the creation of consideration set (sets of possible choice options) relies on both goal-directed attention and peripheral vision. These results could explain how visually similar packaging positively influences market leaders, while making novel brands almost invisible on supermarket shelves. The findings show that even though unsold products might be unseen, in the sense that they have not been directly observed, they might still have been evaluated and excluded by means of peripheral vision. This article is based on controlled lab experiments as well as a field study conducted in a complex retail environment. Thus, the findings are valid both under controlled and ecologically valid conditions. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Lessons Learned from the Creation of a Center of Excellence in Low Vision and Vision Rehabilitation in Wenzhou, China

    ERIC Educational Resources Information Center

    Marinoff, Rebecca; Heilberger, Michael H.

    2017-01-01

    A model Center of Excellence in Low Vision and Vision Rehabilitation was created in a health care setting in China utilizing an inter-institutional relationship with a United States optometric institution. Accomplishments of, limitations to, and stimuli to the provision of low vision and vision rehabilitation services are shared.

  2. Pyramidal neurovision architecture for vision machines

    NASA Astrophysics Data System (ADS)

    Gupta, Madan M.; Knopf, George K.

    1993-08-01

    The vision system employed by an intelligent robot must be active; active in the sense that it must be capable of selectively acquiring the minimal amount of relevant information for a given task. An efficient active vision system architecture that is based loosely upon the parallel-hierarchical (pyramidal) structure of the biological visual pathway is presented in this paper. Although the computational architecture of the proposed pyramidal neuro-vision system is far less sophisticated than the architecture of the biological visual pathway, it does retain some essential features such as the converging multilayered structure of its biological counterpart. In terms of visual information processing, the neuro-vision system is constructed from a hierarchy of several interactive computational levels, whereupon each level contains one or more nonlinear parallel processors. Computationally efficient vision machines can be developed by utilizing both the parallel and serial information processing techniques within the pyramidal computing architecture. A computer simulation of a pyramidal vision system for active scene surveillance is presented.

  3. Characterization of Stereo Vision Performance for Roving at the Lunar Poles

    NASA Technical Reports Server (NTRS)

    Wong, Uland; Nefian, Ara; Edwards, Larry; Furlong, Michael; Bouyssounouse, Xavier; To, Vinh; Deans, Matthew; Cannon, Howard; Fong, Terry

    2016-01-01

    Surface rover operations at the polar regions of airless bodies, particularly the Moon, are of particular interest to future NASA science missions such as Resource Prospector (RP). Polar optical conditions present challenges to conventional imaging techniques, with repercussions to driving, safeguarding and science. High dynamic range, long cast shadows, opposition and white out conditions are all significant factors in appearance. RP is currently undertaking an effort to characterize stereo vision performance in polar conditions through physical laboratory experimentation with regolith simulants, obstacle distributions and oblique lighting.

  4. Vision Loss in Older Adults.

    PubMed

    Pelletier, Allen L; Rojas-Roldan, Ledy; Coffin, Janis

    2016-08-01

    Vision loss affects 37 million Americans older than 50 years and one in four who are older than 80 years. The U.S. Preventive Services Task Force concludes that current evidence is insufficient to assess the balance of benefits and harms of screening for impaired visual acuity in adults older than 65 years. However, family physicians play a critical role in identifying persons who are at risk of vision loss, counseling patients, and referring patients for disease-specific treatment. The conditions that cause most cases of vision loss in older patients are age-related macular degeneration, glaucoma, ocular complications of diabetes mellitus, and age-related cataracts. Vitamin supplements can delay the progression of age-related macular degeneration. Intravitreal injection of a vascular endothelial growth factor inhibitor can preserve vision in the neovascular form of macular degeneration. Medicated eye drops reduce intraocular pressure and can delay the progression of vision loss in patients with glaucoma, but adherence to treatment is poor. Laser trabeculoplasty also lowers intraocular pressure and preserves vision in patients with primary open-angle glaucoma, but long-term studies are needed to identify who is most likely to benefit from surgery. Tight glycemic control in adults with diabetes slows the progression of diabetic retinopathy, but must be balanced against the risks of hypoglycemia and death in older adults. Fenofibrate also slows progression of diabetic retinopathy. Panretinal photocoagulation is the mainstay of treatment for diabetic retinopathy, whereas vascular endothelial growth factor inhibitors slow vision loss resulting from diabetic macular edema. Preoperative testing before cataract surgery does not improve outcomes and is not recommended.

  5. Basic design principles of colorimetric vision systems

    NASA Astrophysics Data System (ADS)

    Mumzhiu, Alex M.

    1998-10-01

    Color measurement is an important part of overall production quality control in textile, coating, plastics, food, paper and other industries. The color measurement instruments such as colorimeters and spectrophotometers, used for production quality control have many limitations. In many applications they cannot be used for a variety of reasons and have to be replaced with human operators. Machine vision has great potential for color measurement. The components for color machine vision systems, such as broadcast quality 3-CCD cameras, fast and inexpensive PCI frame grabbers, and sophisticated image processing software packages are available. However the machine vision industry has only started to approach the color domain. The few color machine vision systems on the market, produced by the largest machine vision manufacturers have very limited capabilities. A lack of understanding that a vision based color measurement system could fail if it ignores the basic principles of colorimetry is the main reason for the slow progress of color vision systems. the purpose of this paper is to clarify how color measurement principles have to be applied to vision systems and how the electro-optical design features of colorimeters have to be modified in order to implement them for vision systems. The subject of this presentation far exceeds the limitations of a journal paper so only the most important aspects will be discussed. An overview of the major areas of applications for colorimetric vision system will be discussed. Finally, the reasons why some customers are happy with their vision systems and some are not will be analyzed.

  6. Vision rehabilitation in the case of blindness.

    PubMed

    Veraart, Claude; Duret, Florence; Brelén, Marten; Oozeer, Medhy; Delbeke, Jean

    2004-09-01

    This article examines the various vision rehabilitation procedures that are available for early and late blindness. Depending on the pathology involved, several vision rehabilitation procedures exist, or are in development. Visual aids are available for low vision individuals, as are sensory aids for blind persons. Most noninvasive sensory substitution prostheses as well as implanted visual prostheses in development are reviewed. Issues dealing with vision rehabilitation are also discussed, such as problems of biocompatibility, electrical safety, psychosocial aspects, and ethics. Basic studies devoted to vision rehabilitation such as simulation in mathematical models and simulation of artificial vision are also presented. Finally, the importance of accurate rehabilitation assessment is addressed, and tentative market figures are given.

  7. Impact of low vision rehabilitation on functional vision performance of children with visual impairment.

    PubMed

    Ganesh, Suma; Sethi, Sumita; Srivastav, Sonia; Chaudhary, Amrita; Arora, Priyanka

    2013-09-01

    To evaluate the impact of low vision rehabilitation on functional vision of children with visual impairment. The LV Prasad-Functional Vision Questionnaire, designed specifically to measure functional performance of visually impaired children of developing countries, was used to assess the level of difficulty in performing various tasks pre and post visual rehabilitation in children with documented visual impairment. Chi-square test was used to assess the impact of rehabilitation intervention on functional vision performance; a P < 0.05 was considered significant. LogMAR visual acuity prior to the introduction of low vision devices (LVDs) was 0.90 ± 0.05 for distance and for near it was 0.61 ± 0.05. After the intervention, the acuities improved significantly for distance (0.2 ± 0.27; P < 0.0001) and near (0.42 ± 0.17; P = 0.001). The most common reported difficulties were related to their academic activities like copying from the blackboard (80%), reading textbook at arm's length (77.2%), and writing along a straight line (77.2%). Absolute raw score of disability pre-LVD was 15.05 which improved to 7.58 post-LVD. An improvement in functional vision post visual rehabilitation was especially found in those activities related to their studying lifestyle like copying from the blackboard (P < 0.0001), reading textbook at arm's length (P < 0.0001), and writing along a straight line (P = 0.003). In our study group, there was a significant improvement in functional vision post visual rehabilitation, especially with those activities which are related to their academic output. It is important for these children to have an early visual rehabilitation to decrease the impairment associated with these decreased visual output and to enhance their learning abilities.

  8. Colour, vision and ergonomics.

    PubMed

    Pinheiro, Cristina; da Silva, Fernando Moreira

    2012-01-01

    This paper is based on a research project - Visual Communication and Inclusive Design-Colour, Legibility and Aged Vision, developed at the Faculty of Architecture of Lisbon. The research has the aim of determining specific design principles to be applied to visual communication design (printed) objects, in order to be easily read and perceived by all. This study target group was composed by a selection of socially active individuals, between 55 and 80 years, and we used cultural events posters as objects of study and observation. The main objective is to overlap the study of areas such as colour, vision, older people's colour vision, ergonomics, chromatic contrasts, typography and legibility. In the end we will produce a manual with guidelines and information to apply scientific knowledge into the communication design projectual practice. Within the normal aging process, visual functions gradually decline; the quality of vision worsens, colour vision and contrast sensitivity are also affected. As people's needs change along with age, design should help people and communities, and improve life quality in the present. Applying principles of visually accessible design and ergonomics, the printed design objects, (or interior spaces, urban environments, products, signage and all kinds of visually information) will be effective, easier on everyone's eyes not only for visually impaired people but also for all of us as we age.

  9. Reliable vision-guided grasping

    NASA Technical Reports Server (NTRS)

    Nicewarner, Keith E.; Kelley, Robert B.

    1992-01-01

    Automated assembly of truss structures in space requires vision-guided servoing for grasping a strut when its position and orientation are uncertain. This paper presents a methodology for efficient and robust vision-guided robot grasping alignment. The vision-guided grasping problem is related to vision-guided 'docking' problems. It differs from other hand-in-eye visual servoing problems, such as tracking, in that the distance from the target is a relevant servo parameter. The methodology described in this paper is hierarchy of levels in which the vision/robot interface is decreasingly 'intelligent,' and increasingly fast. Speed is achieved primarily by information reduction. This reduction exploits the use of region-of-interest windows in the image plane and feature motion prediction. These reductions invariably require stringent assumptions about the image. Therefore, at a higher level, these assumptions are verified using slower, more reliable methods. This hierarchy provides for robust error recovery in that when a lower-level routine fails, the next-higher routine will be called and so on. A working system is described which visually aligns a robot to grasp a cylindrical strut. The system uses a single camera mounted on the end effector of a robot and requires only crude calibration parameters. The grasping procedure is fast and reliable, with a multi-level error recovery system.

  10. The Jeffersonian Vision of Legal Education.

    ERIC Educational Resources Information Center

    Douglas, Davison M.

    2001-01-01

    Explores the Jeffersonian vision of legal education. Examines methods of training lawyers in colonial America, noting that colleges offered no such instruction. Considers Jefferson's vision of the role of education in sustaining a republican form of government and describes the implementation of his vision of legal education first at the college…

  11. The Efficacy of Optometric Vision Therapy.

    ERIC Educational Resources Information Center

    Journal of the American Optometric Association, 1988

    1988-01-01

    This review aims to document the efficacy and validity of vision therapy for modifying and improving vision functioning. The paper describes the essential components of the visual system and disorders which can be physiologically and clinically identified. Vision therapy is defined as a clinical approach for correcting and ameliorating the effects…

  12. Degas: Vision and Perception.

    ERIC Educational Resources Information Center

    Kendall, Richard

    1988-01-01

    The art of Edgar Degas is discussed in relation to his impaired vision, including amblyopia, later blindness in one eye, corneal scarring, and photophobia. Examined are ways in which Degas compensated for vision problems, and dominant themes of his art such as the process of perception and spots of brilliant light. (Author/JDD)

  13. INSIGHT: Vision & Leadership, 2002.

    ERIC Educational Resources Information Center

    McGraw, Tammy, Ed.

    2002-01-01

    This publication focuses on promising new and emerging technologies and what they might mean to the future of K-12 schools. Half of the volume contains articles devoted in some way to "Vision," and articles in the other half are under the heading of "Leadership." Contents in the "Vision" section include: "The…

  14. Contribution of Spaceflight Environmental Factors to Vision Risks

    NASA Technical Reports Server (NTRS)

    Zanello, Susana

    2012-01-01

    The recognition of a risk of visual impairment and intracranial pressure increase as a result of spaceflight has directed our attention and research efforts to the eye. While the alterations observed in astronauts returning from long duration missions include reportable vision and neuroanatomical changes observed by non-invasive methods, other effects and subsequent tissue responses at the molecular and cellular level can only be studied by accessing the tissue itself. As a result of this need, several studies are currently taking place that use animal models for eye research within the HHC Element. The implementation of these studies represents a significant addition to the capabilities of the biomedical research laboratories within the SK3 branch at JSC.

  15. Reinforcement learning in computer vision

    NASA Astrophysics Data System (ADS)

    Bernstein, A. V.; Burnaev, E. V.

    2018-04-01

    Nowadays, machine learning has become one of the basic technologies used in solving various computer vision tasks such as feature detection, image segmentation, object recognition and tracking. In many applications, various complex systems such as robots are equipped with visual sensors from which they learn state of surrounding environment by solving corresponding computer vision tasks. Solutions of these tasks are used for making decisions about possible future actions. It is not surprising that when solving computer vision tasks we should take into account special aspects of their subsequent application in model-based predictive control. Reinforcement learning is one of modern machine learning technologies in which learning is carried out through interaction with the environment. In recent years, Reinforcement learning has been used both for solving such applied tasks as processing and analysis of visual information, and for solving specific computer vision problems such as filtering, extracting image features, localizing objects in scenes, and many others. The paper describes shortly the Reinforcement learning technology and its use for solving computer vision problems.

  16. Development of a machine vision system for automated structural assembly

    NASA Technical Reports Server (NTRS)

    Sydow, P. Daniel; Cooper, Eric G.

    1992-01-01

    Research is being conducted at the LaRC to develop a telerobotic assembly system designed to construct large space truss structures. This research program was initiated within the past several years, and a ground-based test-bed was developed to evaluate and expand the state of the art. Test-bed operations currently use predetermined ('taught') points for truss structural assembly. Total dependence on the use of taught points for joint receptacle capture and strut installation is neither robust nor reliable enough for space operations. Therefore, a machine vision sensor guidance system is being developed to locate and guide the robot to a passive target mounted on the truss joint receptacle. The vision system hardware includes a miniature video camera, passive targets mounted on the joint receptacles, target illumination hardware, and an image processing system. Discrimination of the target from background clutter is accomplished through standard digital processing techniques. Once the target is identified, a pose estimation algorithm is invoked to determine the location, in three-dimensional space, of the target relative to the robots end-effector. Preliminary test results of the vision system in the Automated Structural Assembly Laboratory with a range of lighting and background conditions indicate that it is fully capable of successfully identifying joint receptacle targets throughout the required operational range. Controlled optical bench test results indicate that the system can also provide the pose estimation accuracy to define the target position.

  17. Vision and night driving abilities of elderly drivers.

    PubMed

    Gruber, Nicole; Mosimann, Urs P; Müri, René M; Nef, Tobias

    2013-01-01

    In this article, we review the impact of vision on older people's night driving abilities. Driving is the preferred and primary mode of transport for older people. It is a complex activity where intact vision is seminal for road safety. Night driving requires mesopic rather than scotopic vision, because there is always some light available when driving at night. Scotopic refers to night vision, photopic refers to vision under well-lit conditions, and mesopic vision is a combination of photopic and scotopic vision in low but not quite dark lighting situations. With increasing age, mesopic vision decreases and glare sensitivity increases, even in the absence of ocular diseases. Because of the increasing number of elderly drivers, more drivers are affected by night vision difficulties. Vision tests, which accurately predict night driving ability, are therefore of great interest. We reviewed existing literature on age-related influences on vision and vision tests that correlate or predict night driving ability. We identified several studies that investigated the relationship between vision tests and night driving. These studies found correlations between impaired mesopic vision or increased glare sensitivity and impaired night driving, but no correlation was found among other tests; for example, useful field of view or visual field. The correlation between photopic visual acuity, the most commonly used test when assessing elderly drivers, and night driving ability has not yet been fully clarified. Photopic visual acuity alone is not a good predictor of night driving ability. Mesopic visual acuity and glare sensitivity seem relevant for night driving. Due to the small number of studies evaluating predictors for night driving ability, further research is needed.

  18. Final Report to the National Energy Technology Laboratory on FY09-FY13 Cooperative Research with the Consortium for Electric Reliability Technology Solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vittal, Vijay

    2015-11-04

    The Consortium for Electric Reliability Technology Solutions (CERTS) was formed in 1999 in response to a call from U.S. Congress to restart a federal transmission reliability R&D program to address concerns about the reliability of the U.S. electric power grid. CERTS is a partnership between industry, universities, national laboratories, and government agencies. It researches, develops, and disseminates new methods, tools, and technologies to protect and enhance the reliability of the U.S. electric power system and the efficiency of competitive electricity markets. It is funded by the U.S. Department of Energy’s Office of Electricity Delivery and Energy Reliability (OE). This reportmore » provides an overview of PSERC and CERTS, of the overall objectives and scope of the research, a summary of the major research accomplishments, highlights of the work done under the various elements of the NETL cooperative agreement, and brief reports written by the PSERC researchers on their accomplishments, including research results, publications, and software tools.« less

  19. The changing face of clinical laboratories.

    PubMed

    Plebani, M

    1999-07-01

    Laboratory medicine has undergone a sea change, and medical laboratories must now adapt to, and meet new, customer-supplier needs springing from shifts in the patterns of disease prevalence, medical practice, and demographics. Managed care and other cost-containment processes have forced those involved in health care to cooperate to develop a full picture of patient care, and this has affected clinical laboratory objectives, the main focus now being on improvement in medical outcomes. More recently, the resource shortages in health care and results of cost/effectiveness analysis have demonstrated that the value of a laboratory test must be ascertained not only on the basis of its chemical or clinical performance characteristics, but also by its impact on patient management, the only true assessment of the quality of testing being quality of patient outcomes. The time is ripe for changing the vision of laboratory medicine, and some of the reasons for this are the availability of results in real-time, the introduction of more specific tests, and the trend to prevent diseases rather than cure them. The information from laboratory tests designed to evaluate biochemical or genetic risk and/or prognostic factors cannot be replaced either by physical examination and/or the assessment of symptoms. Today, the importance of laboratory scientists must be proven in three broad areas: a) guaranteeing the quality of tests, irrespective of where they are performed; b) improving the quality of the service; c) maximizing the impact of laboratory information on patient management.

  20. The Vision Thing in Higher Education.

    ERIC Educational Resources Information Center

    Keller, George

    1995-01-01

    It is argued that while the concept of "vision" in higher education has been met with disdain, criticism is based on misconceptions of vision's nature and role--that vision requires a charismatic administrator and that visionaries are dreamers. Educators and planners are urged to use imaginative thinking to connect the institution's and staff's…

  1. What is vision Hampton Roads?

    DOT National Transportation Integrated Search

    2010-01-01

    What is Vision Hampton Roads? : Vision Hampton Roads is... : A regionwide economic development strategy based on the collective strengths of all : localities of Hampton Roads, created with the input of business, academia, nonprofits, : government,...

  2. Creating Strategic Visions

    DTIC Science & Technology

    1990-10-15

    3010 o, AuTOVON 242-3010. - =n~m~m i ma ll lil~ m mm m i mii FOREWORD This futures study presents an analysis and discussion of a program used at the U.S...Operations Research Society, and The Planning Forum . iv CREATING STRATEGIC VISIONS 1 Introduction. The United States Army War College (USAWC) prepares its...consideration and time must be given to a program that attempts to help these potential leaders learn how to create strategic visions. In this paper

  3. New Term, New Vision?

    ERIC Educational Resources Information Center

    Ravenhall, Mark

    2011-01-01

    During the affluent noughties it was sometimes said of government that it had "more visions than Mystic Meg and more pilots than British Airways". In 2011, the pilots, the pathfinders, the new initiatives are largely gone--implementation is the name of the game--but the visions remain. The latest one, as it affects adult learners, is in…

  4. Using Computer Vision Techniques to Locate Objects in an Image

    DTIC Science & Technology

    1988-09-01

    Sujata Kakarla J. Wakeley A. S. Maida Snf DTIC SL7CTE0 ;r’!•,,/ )N ATMT~~c.N T" A TICIINICAL REPORT " SR 10 •: 1"R! _ IrIi) The Pennsylvania State...University APPLIED RESEARCH LABORATORY P. 0. Box 30 State College, PA 16804 USING COMPUTER VISION TECHNIQUES TO LOCATE OBJECTS IN AN IMAGE by Sujata Kakarla J...in an Image 12 PERSONAL AUTHOR(S) Sujata Kakarla, J. Wakelev, A. S. Maida 𔃽a TYPE OF REPORT 13b TIME COVERED 14 DATE OF REPORT (Y ar, Month, Day) 5

  5. Computed Tomography Scanning and Geophysical Measurements of Core from the Coldstream 1MH Well

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crandall, Dustin M.; Brown, Sarah; Moore, Johnathan E.

    The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) Morgantown, West Virginia site were used to characterize core of the Marcellus Shale from a vertical well, the Coldstream 1MH Well in Clearfield County, PA. The core is comprised primarily of the Marcellus Shale from a depth of 7,002 to 7,176 ft. The primary impetus of this work is a collaboration between West Virginia University (WVU) and NETL to characterize core from multiple wells to better understand the structure and variation of the Marcellus and Utica shale formations. As part of thismore » effort, bulk scans of core were obtained from the Coldstream 1MH well, provided by the Energy Corporation of America (now Greylock Energy). This report, and the associated scans, provide detailed datasets not typically available from unconventional shales for analysis. The resultant datasets are presented in this report, and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/coldstream-1mh-well. All equipment and techniques used were non-destructive, enabling future examinations to be performed on these cores. None of the equipment used was suitable for direct visualization of the shale pore space, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with x-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. En echelon fractures were observed at 7,100 ft and were CT scanned using NETL’s industrial CT scanner at higher resolution. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future

  6. Temporary effects of alcohol on color vision

    NASA Astrophysics Data System (ADS)

    Geniusz, Maciej K.; Geniusz, Malwina; Szmigiel, Marta; Przeździecka-Dołyk, Joanna

    2017-09-01

    The color vision has been described as one to be very sensitive to the intake of several chemicals. The present research reviews the published literature that is concerned with color vision impairment due to alcohol. Most of this research considers people under long-term effects of alcohol. However, there is little information about temporary effects of alcohol on color vision. A group of ten volunteers aged 18-40 was studied. During the study levels of alcohol in the body were tested with a standard breathalyzer while color vision were studied using Farnsworth Munsell 100 Hue Color Vision Tests. Keywords: Col

  7. Utica Shale Energy and Environment Laboratory (USEEL)

    NASA Astrophysics Data System (ADS)

    Cole, D. R.

    2017-12-01

    Despite the rapid growth of the UOG industry in the Appalachian Basin of Pennsylvania and neighboring states, there are still fundamental concerns regarding the environmentally sound and cost efficient extraction of this unique asset. To address these concerns, Ohio State University has established the Department of Energy-funded Utica Shale Energy and Environment Laboratory, a dedicated research program where scientists from the university will work with the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL), academia, industry, and regulatory partners, to measure and monitor reservoir response to UOG development and any associated environmental concerns. The USEEL site will be located in Greene County, Pennsylvania, in the heart of the deep Utica-Pt. Pleasant Shale play of the Appalachian Basin. The USEEL project team will characterize and quantify the gas-producing attributes of one of the deepest portions of the Utica-Pt. Pleasant formations in the Appalachian Basin via a multi-disciplinary collaboration that leverages state-of-the-art capabilities in geochemistry, core assessment, well design and logging, 3-D and micro-seismic, DTS and DAS fiber optics, and reservoir modelling. Fracture and rock strength analyses will be complemented by a comprehensive suite of geophysical and geochemical logs, water and chip samples, and cores (pressure sidewall and whole core) to evaluate fluids, mineral alteration, microbes, pore structure, and hydrocarbon formation and alteration in the shale pore space. Located on an existing Marcellus drill pads in southwestern Pennsylvania, USEEL will provide an unprecedented opportunity to evaluate the economic and environmental effects of Marcellus pad expansion on the integrity of near-by existing production wells, ground disruption and slope stability, and ultimate efforts to conduct site reclamation. Combined with the overall goal of an improved understanding of the Utica-Pt. Pleasant system, USEEL

  8. Low Vision Training in Sweden.

    ERIC Educational Resources Information Center

    Inde, Krister

    1978-01-01

    The article describes the team work approach used in Sweden to provide services to the four main categories of visual impairment: central scotoma, nystagmus, loss of peripheral vision while retaining central vision, and amblyopia. (Author/PHR)

  9. A wonderful laboratory and a great researcher

    NASA Astrophysics Data System (ADS)

    Sheikh, N. M.

    2004-05-01

    It was great to be associated with Prof. Dr. Karl Rawer. He devoted his life to make use of the wonderful laboratory of Nature, the Ionosphere. Through acquisition of the experimental data from AEROS satellites and embedding it with data from ground stations, it was possible to achieve a better empirical model, the International Reference Ionosphere. Prof. Dr. Karl Rawer has been as dynamic as the Ionosphere. His vision about the ionospheric data is exceptional and has helped the scientific and engineering community to make use of his vision in advancing the dimensions of empirical modelling. As a human being, Prof. Dr. Karl Rawer has all the traits of an angel from Heaven. In short he developed a large team of researchers forming a blooming tree from the parent node. Ionosphere still plays an important role in over the horizon HF Radar and GPs satellite data reduction.

  10. Clinical laboratory: bigger is not always better.

    PubMed

    Plebani, Mario

    2018-06-27

    Laboratory services around the world are undergoing substantial consolidation and changes through mechanisms ranging from mergers, acquisitions and outsourcing, primarily based on expectations to improve efficiency, increasing volumes and reducing the cost per test. However, the relationship between volume and costs is not linear and numerous variables influence the end cost per test. In particular, the relationship between volumes and costs does not span the entire platter of clinical laboratories: high costs are associated with low volumes up to a threshold of 1 million test per year. Over this threshold, there is no linear association between volumes and costs, as laboratory organization rather than test volume more significantly affects the final costs. Currently, data on laboratory errors and associated diagnostic errors and risk for patient harm emphasize the need for a paradigmatic shift: from a focus on volumes and efficiency to a patient-centered vision restoring the nature of laboratory services as an integral part of the diagnostic and therapy process. Process and outcome quality indicators are effective tools to measure and improve laboratory services, by stimulating a competition based on intra- and extra-analytical performance specifications, intermediate outcomes and customer satisfaction. Rather than competing with economic value, clinical laboratories should adopt a strategy based on a set of harmonized quality indicators and performance specifications, active laboratory stewardship, and improved patient safety.

  11. Pleiades Visions

    NASA Astrophysics Data System (ADS)

    Whitehouse, M.

    2016-01-01

    Pleiades Visions (2012) is my new musical composition for organ that takes inspiration from traditional lore and music associated with the Pleiades (Seven Sisters) star cluster from Australian Aboriginal, Native American, and Native Hawaiian cultures. It is based on my doctoral dissertation research incorporating techniques from the fields of ethnomusicology and cultural astronomy; this research likely represents a new area of inquiry for both fields. This large-scale work employs the organ's vast sonic resources to evoke the majesty of the night sky and the expansive landscapes of the homelands of the above-mentioned peoples. Other important themes in Pleiades Visions are those of place, origins, cosmology, and the creation of the world.

  12. A History of Vision Screening.

    ERIC Educational Resources Information Center

    Appelboom, Tina M.

    1985-01-01

    The vision screening program has a long and interesting history involving educators, pediatricians, optometrists, and ophthamologists. This historical review of vision screening in the schools includes a discussion of amblyopia and screening of preschool students. (Author/CB)

  13. Vision and quality-of-life.

    PubMed Central

    Brown, G C

    1999-01-01

    OBJECTIVE: To determine the relationship of visual acuity loss to quality of life. DESIGN: Three hundred twenty-five patients with visual loss to a minimum of 20/40 or greater in at least 1 eye were interviewed in a standardized fashion using a modified VF-14, questionnaire. Utility values were also obtained using both the time trade-off and standard gamble methods of utility assessment. MAIN OUTCOME MEASURES: Best-corrected visual acuity was correlated with the visual function score on the modified VF-14 questionnaire, as well as with utility values obtained using both the time trade-off and standard gamble methods. RESULTS: Decreasing levels of vision in the eye with better acuity correlated directly with decreasing visual function scores on the modified VF-14 questionnaire, as did decreasing utility values using the time trade-off method of utility evaluation. The standard gamble method of utility evaluation was not as directly correlated with vision as the time trade-off method. Age, level of education, gender, race, length of time of visual loss, and the number of associated systemic comorbidities did not significantly affect the time trade-off utility values associated with visual loss in the better eye. The level of reduced vision in the better eye, rather than the specific disease process causing reduced vision, was related to mean utility values. The average person with 20/40 vision in the better seeing eye was willing to trade 2 of every 10 years of life in return for perfect vision (utility value of 0.8), while the average person with counting fingers vision in the better eye was willing to trade approximately 5 of every 10 remaining years of life (utility value of 0.52) in return for perfect vision. CONCLUSIONS: The time trade-off method of utility evaluation appears to be an effective method for assessing quality of life associated with visual loss. Time trade-off utility values decrease in direct conjunction with decreasing vision in the better

  14. Object tracking with stereo vision

    NASA Technical Reports Server (NTRS)

    Huber, Eric

    1994-01-01

    A real-time active stereo vision system incorporating gaze control and task directed vision is described. Emphasis is placed on object tracking and object size and shape determination. Techniques include motion-centroid tracking, depth tracking, and contour tracking.

  15. School Vision of Learning: Urban Setting

    ERIC Educational Resources Information Center

    Guy, Tiffany A.

    2010-01-01

    In this paper, the author develops her school vision of learning. She explains the theories she used to help develop the vision. The author then goes into detail on the methods she will use to make her vision for a school that prepares urban students for a successful life after high school. She takes into account all the stakeholders and how they…

  16. The Visions of World-Class Universities

    ERIC Educational Resources Information Center

    Slyusarenko, Olena

    2015-01-01

    The visions of the top 26 world-class universities of the first 30 in the Shanghai ranking list have been evaluated and compared with the missions of the world's top 20 universities. Applying the content analysis, a group of 48 keywords, which describe the essence of these visions, has been revealed. The average amount of keywords in one vision is…

  17. Using Adaptive Tools and Techniques to Teach a Class of Students Who Are Blind or Low-Vision

    ERIC Educational Resources Information Center

    Supalo, Cary A.; Mallouk, Thomas E.; Amorosi, Christeallia; Lanouette, James; Wohlers, H. David; McEnnis, Kathleen

    2009-01-01

    A brief overview of the 2007 National Federation of the Blind-Jernigan Institute Youth Slam Chemistry Track, a course of study within a science camp that provided firsthand experimental experience to 200 students who are blind and low-vision, is given. For many of these students, this was their first hands-on experience with laboratory chemistry.…

  18. Introduction to the Hebrew Edition of "Visions of Jewish Education--Medabrim Chazon" (Talking Vision)

    ERIC Educational Resources Information Center

    Katzman, Avi; Marom, Daniel

    2007-01-01

    The following is a translation of the introduction to "Medabrim Chazon" (Jerusalem: Keter, 2006), the Hebrew translation of "Visions of Jewish Education," edited by Seymour Fox, Israel Scheffler, and Daniel Marom (Cambridge, 2003). "Visions of Jewish Education" is an effort by leading scholars to improve the quality…

  19. Biological Basis For Computer Vision: Some Perspectives

    NASA Astrophysics Data System (ADS)

    Gupta, Madan M.

    1990-03-01

    Using biology as a basis for the development of sensors, devices and computer vision systems is a challenge to systems and vision scientists. It is also a field of promising research for engineering applications. Biological sensory systems, such as vision, touch and hearing, sense different physical phenomena from our environment, yet they possess some common mathematical functions. These mathematical functions are cast into the neural layers which are distributed throughout our sensory regions, sensory information transmission channels and in the cortex, the centre of perception. In this paper, we are concerned with the study of the biological vision system and the emulation of some of its mathematical functions, both retinal and visual cortex, for the development of a robust computer vision system. This field of research is not only intriguing, but offers a great challenge to systems scientists in the development of functional algorithms. These functional algorithms can be generalized for further studies in such fields as signal processing, control systems and image processing. Our studies are heavily dependent on the the use of fuzzy - neural layers and generalized receptive fields. Building blocks of such neural layers and receptive fields may lead to the design of better sensors and better computer vision systems. It is hoped that these studies will lead to the development of better artificial vision systems with various applications to vision prosthesis for the blind, robotic vision, medical imaging, medical sensors, industrial automation, remote sensing, space stations and ocean exploration.

  20. Altered vision destabilizes gait in older persons.

    PubMed

    Helbostad, Jorunn L; Vereijken, Beatrix; Hesseberg, Karin; Sletvold, Olav

    2009-08-01

    This study assessed the effects of dim light and four experimentally induced changes in vision on gait speed and footfall and trunk parameters in older persons walking on level ground. Using a quasi-experimental design, gait characteristics were assessed in full light, dim light, and in dim light combined with manipulations resulting in reduced depth vision, double vision, blurred vision, and tunnel vision, respectively. A convenience sample of 24 home-dwelling older women and men (mean age 78.5 years, SD 3.4) with normal vision for their age and able to walk at least 10 m without assistance participated. Outcome measures were gait speed and spatial and temporal parameters of footfall and trunk acceleration, derived from an electronic gait mat and accelerometers. Dim light alone had no effect. Vision manipulations combined with dim light had effect on most footfall parameters but few trunk parameters. The largest effects were found regarding double and tunnel vision. Men increased and women decreased gait speed following manipulations (p=0.017), with gender differences also in stride velocity variability (p=0.017) and inter-stride medio-lateral trunk acceleration variability (p=0.014). Gender effects were related to differences in body height and physical functioning. Results indicate that visual problems lead to a more cautious and unstable gait pattern even under relatively simple conditions. This points to the importance of assessing vision in older persons and correcting visual impairments where possible.

  1. Knowledge-based vision and simple visual machines.

    PubMed Central

    Cliff, D; Noble, J

    1997-01-01

    The vast majority of work in machine vision emphasizes the representation of perceived objects and events: it is these internal representations that incorporate the 'knowledge' in knowledge-based vision or form the 'models' in model-based vision. In this paper, we discuss simple machine vision systems developed by artificial evolution rather than traditional engineering design techniques, and note that the task of identifying internal representations within such systems is made difficult by the lack of an operational definition of representation at the causal mechanistic level. Consequently, we question the nature and indeed the existence of representations posited to be used within natural vision systems (i.e. animals). We conclude that representations argued for on a priori grounds by external observers of a particular vision system may well be illusory, and are at best place-holders for yet-to-be-identified causal mechanistic interactions. That is, applying the knowledge-based vision approach in the understanding of evolved systems (machines or animals) may well lead to theories and models that are internally consistent, computationally plausible, and entirely wrong. PMID:9304684

  2. Vision Restoration in Glaucoma by Activating Residual Vision with a Holistic, Clinical Approach: A Review.

    PubMed

    Sabel, Bernhard A; Cárdenas-Morales, Lizbeth; Gao, Ying

    2018-01-01

    How to cite this article: Sabel BA, Cárdenas-Morales L, Gao Y. Vision Restoration in Glaucoma by activating Residual Vision with a Holistic, Clinical Approach: A Review. J Curr Glaucoma Pract 2018;12(1):1-9.

  3. The Medawar Lecture 2001 Knowledge for vision: vision for knowledge

    PubMed Central

    Gregory, Richard L

    2005-01-01

    An evolutionary development of perception is suggested—from passive reception to active perception to explicit conception—earlier stages being largely retained and incorporated in later species. A key is innate and then individually learned knowledge, giving meaning to sensory signals. Inappropriate or misapplied knowledge produces rich cognitive phenomena of illusions, revealing normally hidden processes of vision, tentatively classified here in a ‘peeriodic table’. Phenomena of physiology are distinguished from phenomena of general rules and specific object knowledge. It is concluded that vision uses implicit knowledge, and provides knowledge for intelligent behaviour and for explicit conceptual understanding including science. PMID:16147519

  4. Functional vision in children with perinatal brain damage.

    PubMed

    Alimović, Sonja; Jurić, Nikolina; Bošnjak, Vlatka Mejaški

    2014-09-01

    Many authors have discussed the effects of visual stimulations on visual functions, but there is no research about the effects on using vision in everyday activities (i.e. functional vision). Children with perinatal brain damage can develop cerebral visual impairment with preserved visual functions (e.g. visual acuity, contrast sensitivity) but poor functional vision. Our aim was to discuss the importance of assessing and stimulating functional vision in children with perinatal brain damage. We assessed visual functions (grating visual acuity, contrast sensitivity) and functional vision (the ability of maintaining visual attention and using vision in communication) in 99 children with perinatal brain damage and visual impairment. All children were assessed before and after the visual stimulation program. Our first assessment results showed that children with perinatal brain damage had significantly more problems in functional vision than in basic visual functions. During the visual stimulation program both variables of functional vision and contrast sensitivity improved significantly, while grating acuity improved only in 2.7% of children. We also found that improvement of visual attention significantly correlated to improvement on all other functions describing vision. Therefore, functional vision assessment, especially assessment of visual attention is indispensable in early monitoring of child with perinatal brain damage.

  5. Accuracy of vision technicians in screening ocular pathology at rural vision centres of southern India.

    PubMed

    Suram, Vasantha; Addepalli, Uday Kumar; Krishnaiah, Sannapaneni; Kovai, Vilas; Khanna, Rohit C

    2016-03-01

    There is paucity of data on the inter-observer agreement and diagnostic accuracy between a primary-care technician (vision technician) and an ophthalmologist. Hence, the current study was conducted to assess the accuracy of vision technicians, to screen potentially sight-threatening ocular conditions at rural vision centres of southern India and their agreement with an ophthalmologist. In July to August 2010, patients presenting to seven vision centres in Adilabad district (Andhra Pradesh) were selected and screened in a masked manner by seven vision technicians followed by an examination by a consultant ophthalmologist. Agreement was assessed between vision technicians and the ophthalmologist for screening of potential sight-threatening ocular conditions and decisions for referral. The ophthalmologist's findings were considered as the reference standard. Two hundred and seventy-nine patients were enrolled at seven vision centres with a mean age of 32.9 ± 21.8 years. Agreement for screening of ocular pathology was 0.82 (95 per cent CI, 0.8-0.83). There was excellent agreement for cataract (0.97; 95 per cent CI, 0.93-1), refractive error (0.98; 95 per cent CI, 0.96-1), corneal pathology (1.0; 95 per cent CI, 1.0-1.0) and other anterior segment pathology (0.95; 95 per cent CI, 0.9-1); the agreement was moderate to fair for detection of glaucoma suspects (0.43; 95 per cent CI, 0.28-0.60) and retinal pathology (0.39; 95 per cent CI, 0.14-0.63). Sensitivity for screening of anterior segment pathology was 94.6-100 per cent. There was a fair to moderate sensitivity for glaucoma suspect; 35.6 per cent (95 per cent CI, 21.9-51.2) and retinal pathology 26.3 per cent (95 per cent CI, 9.2-51.2). Specificity for screening of ocular pathology was 98.2 to 100 per cent. The kappa (κ) agreement for referral for any pathology was 0.82 (0.8-0.83) CONCLUSION: As there is good agreement between the vision technicians and the ophthalmologist for screening and referral of

  6. The evolution of vertebrate color vision.

    PubMed

    Jacobs, Gerald H

    2012-01-01

    Color vision is conventionally defined as the ability of animals to reliably discriminate among objects and lights based solely on differences in their spectral properties. Although the nature of color vision varies widely in different animals, a large majority of all vertebrate species possess some color vision and that fact attests to the adaptive importance this capacity holds as a tool for analyzing the environment. In recent years dramatic advances have been made in our understanding of the nature of vertebrate color vision and of the evolution of the biological mechanisms underlying this capacity. In this chapter I review and comment on these advances.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    NETL's Hybrid Performance, or Hyper, facility is a one-of-a-kind laboratory built to develop control strategies for the reliable operation of fuel cell/turbine hybrids and enable the simulation, design, and implementation of commercial equipment. The Hyper facility provides a unique opportunity for researchers to explore issues related to coupling fuel cell and gas turbine technologies.

  8. General Motors LLC Final Project Report: Improving Energy Efficiency by Developing Components for Distributed Cooling and Heating Based on Thermal Comfort Modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bozeman, Jeffrey; Chen, Kuo-Huey

    2014-12-09

    On November 3, 2009, General Motors (GM) accepted U.S. Department of Energy (DOE) Cooperative Agreement award number DE-EE0000014 from the National Energy Technology Laboratory (NETL). GM was selected to execute a three-year cost shared research and development project on Solid State Energy Conversion for Vehicular Heating, Ventilation & Air Conditioning (HVAC) and for Waste Heat Recovery.

  9. Quaternions in computer vision and robotics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pervin, E.; Webb, J.A.

    1982-01-01

    Computer vision and robotics suffer from not having good tools for manipulating three-dimensional objects. Vectors, coordinate geometry, and trigonometry all have deficiencies. Quaternions can be used to solve many of these problems. Many properties of quaternions that are relevant to computer vision and robotics are developed. Examples are given showing how quaternions can be used to simplify derivations in computer vision and robotics.

  10. Synthetic Vision Workshop 2

    NASA Technical Reports Server (NTRS)

    Kramer, Lynda J. (Compiler)

    1999-01-01

    The second NASA sponsored Workshop on Synthetic/Enhanced Vision (S/EV) Display Systems was conducted January 27-29, 1998 at the NASA Langley Research Center. The purpose of this workshop was to provide a forum for interested parties to discuss topics in the Synthetic Vision (SV) element of the NASA Aviation Safety Program and to encourage those interested parties to participate in the development, prototyping, and implementation of S/EV systems that enhance aviation safety. The SV element addresses the potential safety benefits of synthetic/enhanced vision display systems for low-end general aviation aircraft, high-end general aviation aircraft (business jets), and commercial transports. Attendance at this workshop consisted of about 112 persons including representatives from industry, the FAA, and other government organizations (NOAA, NIMA, etc.). The workshop provided opportunities for interested individuals to give presentations on the state of the art in potentially applicable systems, as well as to discuss areas of research that might be considered for inclusion within the Synthetic Vision Element program to contribute to the reduction of the fatal aircraft accident rate. Panel discussions on topical areas such as databases, displays, certification issues, and sensors were conducted, with time allowed for audience participation.

  11. VLSI chips for vision-based vehicle guidance

    NASA Astrophysics Data System (ADS)

    Masaki, Ichiro

    1994-02-01

    Sensor-based vehicle guidance systems are gathering rapidly increasing interest because of their potential for increasing safety, convenience, environmental friendliness, and traffic efficiency. Examples of applications include intelligent cruise control, lane following, collision warning, and collision avoidance. This paper reviews the research trends in vision-based vehicle guidance with an emphasis on VLSI chip implementations of the vision systems. As an example of VLSI chips for vision-based vehicle guidance, a stereo vision system is described in detail.

  12. VISION User Guide - VISION (Verifiable Fuel Cycle Simulation) Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacob J. Jacobson; Robert F. Jeffers; Gretchen E. Matthern

    2009-08-01

    The purpose of this document is to provide a guide for using the current version of the Verifiable Fuel Cycle Simulation (VISION) model. This is a complex model with many parameters; the user is strongly encouraged to read this user guide before attempting to run the model. This model is an R&D work in progress and may contain errors and omissions. It is based upon numerous assumptions. This model is intended to assist in evaluating “what if” scenarios and in comparing fuel, reactor, and fuel processing alternatives at a systems level for U.S. nuclear power. The model is not intendedmore » as a tool for process flow and design modeling of specific facilities nor for tracking individual units of fuel or other material through the system. The model is intended to examine the interactions among the components of a fuel system as a function of time varying system parameters; this model represents a dynamic rather than steady-state approximation of the nuclear fuel system. VISION models the nuclear cycle at the system level, not individual facilities, e.g., “reactor types” not individual reactors and “separation types” not individual separation plants. Natural uranium can be enriched, which produces enriched uranium, which goes into fuel fabrication, and depleted uranium (DU), which goes into storage. Fuel is transformed (transmuted) in reactors and then goes into a storage buffer. Used fuel can be pulled from storage into either separation of disposal. If sent to separations, fuel is transformed (partitioned) into fuel products, recovered uranium, and various categories of waste. Recycled material is stored until used by its assigned reactor type. Note that recovered uranium is itself often partitioned: some RU flows with recycled transuranic elements, some flows with wastes, and the rest is designated RU. RU comes out of storage if needed to correct the U/TRU ratio in new recycled fuel. Neither RU nor DU are designated as wastes. VISION is comprised of

  13. An architecture for real-time vision processing

    NASA Technical Reports Server (NTRS)

    Chien, Chiun-Hong

    1994-01-01

    To study the feasibility of developing an architecture for real time vision processing, a task queue server and parallel algorithms for two vision operations were designed and implemented on an i860-based Mercury Computing System 860VS array processor. The proposed architecture treats each vision function as a task or set of tasks which may be recursively divided into subtasks and processed by multiple processors coordinated by a task queue server accessible by all processors. Each idle processor subsequently fetches a task and associated data from the task queue server for processing and posts the result to shared memory for later use. Load balancing can be carried out within the processing system without the requirement for a centralized controller. The author concludes that real time vision processing cannot be achieved without both sequential and parallel vision algorithms and a good parallel vision architecture.

  14. Standards for vision science libraries: 2014 revision.

    PubMed

    Motte, Kristin; Caldwell, C Brooke; Lamson, Karen S; Ferimer, Suzanne; Nims, J Chris

    2014-10-01

    This Association of Vision Science Librarians revision of the "Standards for Vision Science Libraries" aspires to provide benchmarks to address the needs for the services and resources of modern vision science libraries (academic, medical or hospital, pharmaceutical, and so on), which share a core mission, are varied by type, and are located throughout the world. Through multiple meeting discussions, member surveys, and a collaborative revision process, the standards have been updated for the first time in over a decade. While the range of types of libraries supporting vision science services, education, and research is wide, all libraries, regardless of type, share core attributes, which the standards address. The current standards can and should be used to help develop new vision science libraries or to expand the growth of existing libraries, as well as to support vision science librarians in their work to better provide services and resources to their respective users.

  15. 75 FR 10993 - Save Your Vision Week, 2010

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-10

    ... Your Vision Week, 2010 By the President of the United States of America A Proclamation While many Americans are fortunate to have healthy eyes, millions are affected by low vision or blindness. Maintaining good vision requires early diagnosis and timely treatment of eye conditions. Save Your Vision Week is a...

  16. 76 FR 12819 - Save Your Vision Week, 2011

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-09

    ... Vision Week, 2011 By the President of the United States of America A Proclamation Across America, millions of men and women experience vision loss or are affected by low vision or blindness. During Save Your Vision Week, we reinforce the importance of routine eye care and remind all Americans to take...

  17. Representing vision and blindness.

    PubMed

    Ray, Patrick L; Cox, Alexander P; Jensen, Mark; Allen, Travis; Duncan, William; Diehl, Alexander D

    2016-01-01

    There have been relatively few attempts to represent vision or blindness ontologically. This is unsurprising as the related phenomena of sight and blindness are difficult to represent ontologically for a variety of reasons. Blindness has escaped ontological capture at least in part because: blindness or the employment of the term 'blindness' seems to vary from context to context, blindness can present in a myriad of types and degrees, and there is no precedent for representing complex phenomena such as blindness. We explore current attempts to represent vision or blindness, and show how these attempts fail at representing subtypes of blindness (viz., color blindness, flash blindness, and inattentional blindness). We examine the results found through a review of current attempts and identify where they have failed. By analyzing our test cases of different types of blindness along with the strengths and weaknesses of previous attempts, we have identified the general features of blindness and vision. We propose an ontological solution to represent vision and blindness, which capitalizes on resources afforded to one who utilizes the Basic Formal Ontology as an upper-level ontology. The solution we propose here involves specifying the trigger conditions of a disposition as well as the processes that realize that disposition. Once these are specified we can characterize vision as a function that is realized by certain (in this case) biological processes under a range of triggering conditions. When the range of conditions under which the processes can be realized are reduced beyond a certain threshold, we are able to say that blindness is present. We characterize vision as a function that is realized as a seeing process and blindness as a reduction in the conditions under which the sight function is realized. This solution is desirable because it leverages current features of a major upper-level ontology, accurately captures the phenomenon of blindness, and can be

  18. Hi-Vision telecine system using pickup tube

    NASA Astrophysics Data System (ADS)

    Iijima, Goro

    1992-08-01

    Hi-Vision broadcasting, offering far more lifelike pictures than those produced by existing television broadcasting systems, has enormous potential in both industrial and commercial fields. The dissemination of the Hi-Vision system will enable vivid, movie theater quality pictures to be readily enjoyed in homes in the near future. To convert motion film pictures into Hi-Vision signals, a telecine system is needed. The Hi-Vision telecine systems currently under development are the "laser telecine," "flying-spot telecine," and "Saticon telecine" systems. This paper provides an overview of the pickup tube type Hi-Vision telecine system (referred to herein as the Saticon telecine system) developed and marketed by Ikegami Tsushinki Co., Ltd.

  19. A conceptual model for vision rehabilitation.

    PubMed

    Roberts, Pamela S; Rizzo, John-Ross; Hreha, Kimberly; Wertheimer, Jeffrey; Kaldenberg, Jennifer; Hironaka, Dawn; Riggs, Richard; Colenbrander, August

    2016-01-01

    Vision impairments are highly prevalent after acquired brain injury (ABI). Conceptual models that focus on constructing intellectual frameworks greatly facilitate comprehension and implementation of practice guidelines in an interprofessional setting. The purpose of this article is to provide a review of the vision literature in ABI, describe a conceptual model for vision rehabilitation, explain its potential clinical inferences, and discuss its translation into rehabilitation across multiple practice settings and disciplines.

  20. Simplifying Complexity: Miriam Blake--Los Alamos National Laboratory Research Library, NM

    ERIC Educational Resources Information Center

    Library Journal, 2004

    2004-01-01

    The holy grail for many research librarians is one-stop searching: seamless access to all the library's resources on a topic, regardless of the source. Miriam Blake, Library Without Walls Project Leader at Los Alamos National laboratory (LANL), is making this vision a reality. Blake is part of a growing cadre of experts: a techie who is becoming a…

  1. The Effect of an On-Site Vision Examination on Adherence to Vision Screening Recommendations

    ERIC Educational Resources Information Center

    Chu, Raymond; Huang, Kristine; Barnhardt, Carmen; Chen, Angela

    2015-01-01

    Vision screenings are intended to efficiently identify students with possible visual impairment and initiate a referral for diagnosis and treatment. In many cases, at-risk students do not access the recommended care or experience delays in receiving care. The purpose of this article is to report the effect on adherence to vision screening…

  2. Near vision spectacle coverage and barriers to near vision correction among adults in the Cape Coast Metropolis of Ghana.

    PubMed

    Ntodie, Michael; Abu, Sampson L; Kyei, Samuel; Abokyi, Samuel; Abu, Emmanuel K

    2017-06-01

    To determine the near vision spectacle coverage and barriers to obtaining near vision correction among adults aged 35 years and older in the Cape Coast Metropolis of Ghana. A population-based cross-sectional study design was adopted and 500 out of 576 participants aged 35 years and older were examined from 12 randomly selected clusters in Cape Coast, Ghana. All participants underwent a comprehensive eye examination which included: distance and near visual acuities measurements and external and internal ocular health assessments. Distance and near refractions were performed using subjective refraction technique. Information on participants' demographics, near vision correction status, near visual needs and barriers to acquiring near vision correction were obtained through a questionnaire administered as part of the study. The mean age of participants was 52.3±10.3 years of whom 280 (56%) were females and 220 (44%) were males. The near vision spectacle coverage was 25%, 33% "met need" for near vision correction in the presbyopic population, and 64% unmet need in the entire study population. After controlling for other variables, age (5 th and 6 th decades) and educational level were associated with "met need" for near vision correction (OR=2.7 (1.55-4.68), p =0.00, and OR=2.36 (1.18-4.72), p=0.02 respectively). Among those who needed but did not have near vision correction, 64 (26%) did not feel the need for correction, 55 (22%) stated that they were unaware of available interventions, and 53 (21%) found the cost of near vision correction prohibitive. There was a low near vision spectacle coverage in this population which suggests the need for strategies on health education and promotion to address the lack of awareness of spectacle need and cost of services.

  3. Vision in our three-dimensional world

    PubMed Central

    2016-01-01

    Many aspects of our perceptual experience are dominated by the fact that our two eyes point forward. Whilst the location of our eyes leaves the environment behind our head inaccessible to vision, co-ordinated use of our two eyes gives us direct access to the three-dimensional structure of the scene in front of us, through the mechanism of stereoscopic vision. Scientific understanding of the different brain regions involved in stereoscopic vision and three-dimensional spatial cognition is changing rapidly, with consequent influences on fields as diverse as clinical practice in ophthalmology and the technology of virtual reality devices. This article is part of the themed issue ‘Vision in our three-dimensional world’. PMID:27269595

  4. The Effect on Vision of Light Scatter From HMD Visors and Aircraft Windscreens

    DTIC Science & Technology

    1999-01-01

    This paper was cleared by ASC99-0447 on 5 Mar 1999 The Effect on Vision of Light Scatter from HMD Visors and Aircraft Windscreens Peter L. Marasco ...Medical Research Laboratory, Wright-Patterson AFB, Ohio. BIOGRAPHIES This paper was cleared by ASC99-0447 on 5 Mar 1999 Peter Marasco came to the U.S. Air...and improving optical test methods. Mr. Marasco received a BS degree from the University of Rochester in 1991 and an MS degree from the University of

  5. Age-Related Psychophysical Changes and Low Vision

    PubMed Central

    Dagnelie, Gislin

    2013-01-01

    When considering the burden of visual impairment on aging individuals and society at large, it is important to bear in mind that vision changes are a natural aspect of aging. In this article, we consider vision changes that are part of normal aging, the prevalence of abnormal vision changes caused by disorders of the visual system, and the anticipated incidence and impact of visual impairment as the US population ages. We then discuss the services available to reduce the impact of vision loss, and the extent to which those services can and should be improved, not only to be better prepared for the anticipated increase in low vision over the coming decades, but also to increase the awareness of interactions between visual impairment and comorbidities that are common among the elderly. Finally, we consider how to promote improved quality, availability, and acceptance of low vision care to lessen the impact of visual impairment on individuals, and its burden on society. PMID:24335074

  6. Standards for vision science libraries: 2014 revision

    PubMed Central

    Motte, Kristin; Caldwell, C. Brooke; Lamson, Karen S.; Ferimer, Suzanne; Nims, J. Chris

    2014-01-01

    Objective: This Association of Vision Science Librarians revision of the “Standards for Vision Science Libraries” aspires to provide benchmarks to address the needs for the services and resources of modern vision science libraries (academic, medical or hospital, pharmaceutical, and so on), which share a core mission, are varied by type, and are located throughout the world. Methods: Through multiple meeting discussions, member surveys, and a collaborative revision process, the standards have been updated for the first time in over a decade. Results: While the range of types of libraries supporting vision science services, education, and research is wide, all libraries, regardless of type, share core attributes, which the standards address. Conclusions: The current standards can and should be used to help develop new vision science libraries or to expand the growth of existing libraries, as well as to support vision science librarians in their work to better provide services and resources to their respective users. PMID:25349547

  7. Demographic and clinical characteristics of a paediatric low vision population in a low vision clinic in China.

    PubMed

    Gao, Guohong; Yu, Manrong; Dai, Jinhui; Xue, Feng; Wang, Xiaoying; Zou, Leilei; Chen, Minjie; Ma, Fei

    2016-05-01

    The aim was to describe the characteristics of the paediatric population attending the low vision clinic of the Eye and ENT Hospital, located in Shanghai, China. The clinical records of all the children attending the low vision clinic of Eye and ENT Hospital affiliated to Fudan University between January 1, 2009 and May 31, 2014 were retrospectively reviewed. The main data analysed were age, gender, education, visual demand, diagnosis, visual acuity and prescription of low vision aids. Of the 162 patients, 104 (64.20 per cent) were male. The age range of the study population was three to 20 years, with a mean of 10.73 ± 5.08 years. There were 43.21 per cent with moderate visual impairment, 26.54 per cent had severe visual impairment and 19.75 per cent were blind. The leading causes of visual impairment were congenital cataract (21.61 per cent), optic atrophy (14.20 per cent), macular dystrophy (11.73 per cent), nystagmus (9.88 per cent) and congenital glaucoma (9.26 per cent). The most frequently prescribed low vision devices for distant and near vision were binocular telescopes (23.57 per cent) and stand magnifiers (22.93 per cent), respectively. Young age (up to six years, 37.93 per cent), high cost (24.14 per cent), cosmetic reasons (17.24 per cent) and inconvenience (13.79 per cent) were the main reasons that children or parents refused to accept useful low vision aids. Congenital and hereditary diseases constituted the major causes of low vision in the study population. Strategies that make good-quality rehabilitation services available, affordable and accessible, especially in developing countries, will have the greatest impact on visual impairment. In China, both urban and rural, the coverage of low vision services should be strengthened. © 2016 The Authors. Clinical and Experimental Optometry © 2016 Optometry Australia.

  8. A conceptual model for vision rehabilitation

    PubMed Central

    Roberts, Pamela S.; Rizzo, John-Ross; Hreha, Kimberly; Wertheimer, Jeffrey; Kaldenberg, Jennifer; Hironaka, Dawn; Riggs, Richard; Colenbrander, August

    2017-01-01

    Vision impairments are highly prevalent after acquired brain injury (ABI). Conceptual models that focus on constructing intellectual frameworks greatly facilitate comprehension and implementation of practice guidelines in an interprofessional setting. The purpose of this article is to provide a review of the vision literature in ABI, describe a conceptual model for vision rehabilitation, explain its potential clinical inferences, and discuss its translation into rehabilitation across multiple practice settings and disciplines. PMID:27997671

  9. Functional vision loss: a diagnosis of exclusion.

    PubMed

    Villegas, Rex B; Ilsen, Pauline F

    2007-10-01

    Most cases of visual acuity or visual field loss can be attributed to ocular pathology or ocular manifestations of systemic pathology. They can also occasionally be attributed to nonpathologic processes or malingering. Functional vision loss is any decrease in vision the origin of which cannot be attributed to a pathologic or structural abnormality. Two cases of functional vision loss are described. In the first, a 58-year-old man presented for a baseline eye examination for enrollment in a vision rehabilitation program. He reported bilateral blindness since a motor vehicle accident with head trauma 4 years prior. Entering visual acuity was "no light perception" in each eye. Ocular health examination was normal and the patient made frequent eye contact with the examiners. He was referred for neuroimaging and electrophysiologic testing. The second case was a 49-year-old man who presented with a long history of intermittent monocular diplopia. His medical history was significant for psycho-medical evaluations and a diagnosis of factitious disorder. Entering uncorrected visual acuities were 20/20 in each eye, but visual field testing found constriction. No abnormalities were found that could account for the monocular diplopia or visual field deficit. A diagnosis of functional vision loss secondary to factitious disorder was made. Functional vision loss is a diagnosis of exclusion. In the event of reduced vision in the context of a normal ocular health examination, all other pathology must be ruled out before making the diagnosis of functional vision loss. Evaluation must include auxiliary ophthalmologic testing, neuroimaging of the visual pathway, review of the medical history and lifestyle, and psychiatric evaluation. Comanagement with a psychiatrist is essential for patients with functional vision loss.

  10. Comparative effects of pH and Vision herbicide on two life stages of four anuran amphibian species.

    PubMed

    Edginton, Andrea N; Sheridan, Patrick M; Stephenson, Gerald R; Thompson, Dean G; Boermans, Herman J

    2004-04-01

    Vision, a glyphosate-based herbicide containing a 15% (weight:weight) polyethoxylated tallow amine surfactant blend, and the concurrent factor of pH were tested to determine their interactive effects on early life-stage anurans. Ninety-six-hour laboratory static renewal studies, using the embryonic and larval life stages (Gosner 25) of Rana clamitans, R. pipiens, Bufo americanus, and Xenopus laevis, were performed under a central composite rotatable design. Mortality and the prevalence of malformations were modeled using generalized linear models with a profile deviance approach for obtaining confidence intervals. There was a significant (p < 0.05) interaction of pH with Vision concentration in all eight models, such that the toxicity of Vision was amplified by elevated pH. The surfactant is the major toxic component of Vision and is hypothesized, in this study, to be the source of the pH interaction. Larvae of B. americanus and R. clamitans were 1.5 to 3.8 times more sensitive than their corresponding embryos, whereas X. laevis and R. pipiens larvae were 6.8 to 8.9 times more sensitive. At pH values above 7.5, the Vision concentrations expected to kill 50% of the test larvae in 96-h (96-h lethal concentration [LC50]) were predicted to be below the expected environmental concentration (EEC) as calculated by Canadian regulatory authorities. The EEC value represents a worst-case scenario for aerial Vision application and is calculated assuming an application of the maximum label rate (2.1 kg acid equivalents [a.e.]/ha) into a pond 15 cm in depth. The EEC of 1.4 mg a.e./L (4.5 mg/L Vision) was not exceeded by 96-h LC50 values for the embryo test. The larvae of the four species were comparable in sensitivity. Field studies should be completed using the more sensitive larval life stage to test for Vision toxicity at actual environmental concentrations.

  11. A High-Speed Target-Free Vision-Based Sensor for Bus Rapid Transit Viaduct Vibration Measurements Using CMT and ORB Algorithms.

    PubMed

    Hu, Qijun; He, Songsheng; Wang, Shilong; Liu, Yugang; Zhang, Zutao; He, Leping; Wang, Fubin; Cai, Qijie; Shi, Rendan; Yang, Yuan

    2017-06-06

    Bus Rapid Transit (BRT) has become an increasing source of concern for public transportation of modern cities. Traditional contact sensing techniques during the process of health monitoring of BRT viaducts cannot overcome the deficiency that the normal free-flow of traffic would be blocked. Advances in computer vision technology provide a new line of thought for solving this problem. In this study, a high-speed target-free vision-based sensor is proposed to measure the vibration of structures without interrupting traffic. An improved keypoints matching algorithm based on consensus-based matching and tracking (CMT) object tracking algorithm is adopted and further developed together with oriented brief (ORB) keypoints detection algorithm for practicable and effective tracking of objects. Moreover, by synthesizing the existing scaling factor calculation methods, more rational approaches to reducing errors are implemented. The performance of the vision-based sensor is evaluated through a series of laboratory tests. Experimental tests with different target types, frequencies, amplitudes and motion patterns are conducted. The performance of the method is satisfactory, which indicates that the vision sensor can extract accurate structure vibration signals by tracking either artificial or natural targets. Field tests further demonstrate that the vision sensor is both practicable and reliable.

  12. A High-Speed Target-Free Vision-Based Sensor for Bus Rapid Transit Viaduct Vibration Measurements Using CMT and ORB Algorithms

    PubMed Central

    Hu, Qijun; He, Songsheng; Wang, Shilong; Liu, Yugang; Zhang, Zutao; He, Leping; Wang, Fubin; Cai, Qijie; Shi, Rendan; Yang, Yuan

    2017-01-01

    Bus Rapid Transit (BRT) has become an increasing source of concern for public transportation of modern cities. Traditional contact sensing techniques during the process of health monitoring of BRT viaducts cannot overcome the deficiency that the normal free-flow of traffic would be blocked. Advances in computer vision technology provide a new line of thought for solving this problem. In this study, a high-speed target-free vision-based sensor is proposed to measure the vibration of structures without interrupting traffic. An improved keypoints matching algorithm based on consensus-based matching and tracking (CMT) object tracking algorithm is adopted and further developed together with oriented brief (ORB) keypoints detection algorithm for practicable and effective tracking of objects. Moreover, by synthesizing the existing scaling factor calculation methods, more rational approaches to reducing errors are implemented. The performance of the vision-based sensor is evaluated through a series of laboratory tests. Experimental tests with different target types, frequencies, amplitudes and motion patterns are conducted. The performance of the method is satisfactory, which indicates that the vision sensor can extract accurate structure vibration signals by tracking either artificial or natural targets. Field tests further demonstrate that the vision sensor is both practicable and reliable. PMID:28587275

  13. 21 CFR 886.1170 - Color vision tester.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Color vision tester. 886.1170 Section 886.1170...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1170 Color vision tester. (a) Identification. A color vision tester is a device that consists of various colored materials, such as colored yarns...

  14. 21 CFR 886.1170 - Color vision tester.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Color vision tester. 886.1170 Section 886.1170...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1170 Color vision tester. (a) Identification. A color vision tester is a device that consists of various colored materials, such as colored yarns...

  15. 21 CFR 886.1170 - Color vision tester.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Color vision tester. 886.1170 Section 886.1170...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1170 Color vision tester. (a) Identification. A color vision tester is a device that consists of various colored materials, such as colored yarns...

  16. 21 CFR 886.5900 - Electronic vision aid.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Electronic vision aid. 886.5900 Section 886.5900...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5900 Electronic vision aid. (a) Identification. An electronic vision aid is an AC-powered or battery-powered device that consists of an...

  17. 21 CFR 886.5900 - Electronic vision aid.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Electronic vision aid. 886.5900 Section 886.5900...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5900 Electronic vision aid. (a) Identification. An electronic vision aid is an AC-powered or battery-powered device that consists of an...

  18. 21 CFR 886.5900 - Electronic vision aid.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Electronic vision aid. 886.5900 Section 886.5900...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5900 Electronic vision aid. (a) Identification. An electronic vision aid is an AC-powered or battery-powered device that consists of an...

  19. 21 CFR 886.5900 - Electronic vision aid.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Electronic vision aid. 886.5900 Section 886.5900...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5900 Electronic vision aid. (a) Identification. An electronic vision aid is an AC-powered or battery-powered device that consists of an...

  20. 16 CFR 1203.14 - Peripheral vision test.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Peripheral vision test. 1203.14 Section 1203... SAFETY STANDARD FOR BICYCLE HELMETS The Standard § 1203.14 Peripheral vision test. Position the helmet on... the helmet to set the comfort or fit padding. (Note: Peripheral vision clearance may be determined...

  1. 21 CFR 886.5900 - Electronic vision aid.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electronic vision aid. 886.5900 Section 886.5900...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5900 Electronic vision aid. (a) Identification. An electronic vision aid is an AC-powered or battery-powered device that consists of an...

  2. 16 CFR 1203.14 - Peripheral vision test.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Peripheral vision test. 1203.14 Section 1203... SAFETY STANDARD FOR BICYCLE HELMETS The Standard § 1203.14 Peripheral vision test. Position the helmet on... the helmet to set the comfort or fit padding. (Note: Peripheral vision clearance may be determined...

  3. 21 CFR 886.1170 - Color vision tester.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Color vision tester. 886.1170 Section 886.1170...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1170 Color vision tester. (a) Identification. A color vision tester is a device that consists of various colored materials, such as colored yarns...

  4. 21 CFR 886.1170 - Color vision tester.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Color vision tester. 886.1170 Section 886.1170...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1170 Color vision tester. (a) Identification. A color vision tester is a device that consists of various colored materials, such as colored yarns...

  5. Quality Control by Artificial Vision

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lam, Edmond Y.; Gleason, Shaun Scott; Niel, Kurt S.

    2010-01-01

    Computational technology has fundamentally changed many aspects of our lives. One clear evidence is the development of artificial-vision systems, which have effectively automated many manual tasks ranging from quality inspection to quantitative assessment. In many cases, these machine-vision systems are even preferred over manual ones due to their repeatability and high precision. Such advantages come from significant research efforts in advancing sensor technology, illumination, computational hardware, and image-processing algorithms. Similar to the Special Section on Quality Control by Artificial Vision published two years ago in Volume 17, Issue 3 of the Journal of Electronic Imaging, the present one invited papersmore » relevant to fundamental technology improvements to foster quality control by artificial vision, and fine-tuned the technology for specific applications. We aim to balance both theoretical and applied work pertinent to this special section theme. Consequently, we have seven high-quality papers resulting from the stringent peer-reviewing process in place at the Journal of Electronic Imaging. Some of the papers contain extended treatment of the authors work presented at the SPIE Image Processing: Machine Vision Applications conference and the International Conference on Quality Control by Artificial Vision. On the broad application side, Liu et al. propose an unsupervised texture image segmentation scheme. Using a multilayer data condensation spectral clustering algorithm together with wavelet transform, they demonstrate the effectiveness of their approach on both texture and synthetic aperture radar images. A problem related to image segmentation is image extraction. For this, O'Leary et al. investigate the theory of polynomial moments and show how these moments can be compared to classical filters. They also show how to use the discrete polynomial-basis functions for the extraction of 3-D embossed digits, demonstrating superiority over Fourier

  6. Integrating National Space Visions

    NASA Technical Reports Server (NTRS)

    Sherwood, Brent

    2006-01-01

    This paper examines value proposition assumptions for various models nations may use to justify, shape, and guide their space programs. Nations organize major societal investments like space programs to actualize national visions represented by leaders as investments in the public good. The paper defines nine 'vision drivers' that circumscribe the motivations evidently underpinning national space programs. It then describes 19 fundamental space activity objectives (eight extant and eleven prospective) that nations already do or could in the future use to actualize the visions they select. Finally the paper presents four contrasting models of engagement among nations, and compares these models to assess realistic pounds on the pace of human progress in space over the coming decades. The conclusion is that orthogonal engagement, albeit unlikely because it is unprecedented, would yield the most robust and rapid global progress.

  7. Overview of sports vision

    NASA Astrophysics Data System (ADS)

    Moore, Linda A.; Ferreira, Jannie T.

    2003-03-01

    Sports vision encompasses the visual assessment and provision of sports-specific visual performance enhancement and ocular protection for athletes of all ages, genders and levels of participation. In recent years, sports vision has been identified as one of the key performance indicators in sport. It is built on four main cornerstones: corrective eyewear, protective eyewear, visual skills enhancement and performance enhancement. Although clinically well established in the US, it is still a relatively new area of optometric specialisation elsewhere in the world and is gaining increasing popularity with eyecare practitioners and researchers. This research is often multi-disciplinary and involves input from a variety of subject disciplines, mainly those of optometry, medicine, physiology, psychology, physics, chemistry, computer science and engineering. Collaborative research projects are currently underway between staff of the Schools of Physics and Computing (DIT) and the Academy of Sports Vision (RAU).

  8. 21 CFR 886.5540 - Low-vision magnifier.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Low-vision magnifier. 886.5540 Section 886.5540...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5540 Low-vision magnifier. (a) Identification. A low-vision magnifier is a device that consists of a magnifying lens intended for use by a patient...

  9. 21 CFR 886.5870 - Low-vision telescope.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Low-vision telescope. 886.5870 Section 886.5870...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5870 Low-vision telescope. (a) Identification. A low-vision telescope is a device that consists of an arrangement of lenses or mirrors intended for...

  10. 21 CFR 886.5540 - Low-vision magnifier.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Low-vision magnifier. 886.5540 Section 886.5540...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5540 Low-vision magnifier. (a) Identification. A low-vision magnifier is a device that consists of a magnifying lens intended for use by a patient...

  11. 21 CFR 886.5870 - Low-vision telescope.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Low-vision telescope. 886.5870 Section 886.5870...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5870 Low-vision telescope. (a) Identification. A low-vision telescope is a device that consists of an arrangement of lenses or mirrors intended for...

  12. 21 CFR 886.5540 - Low-vision magnifier.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Low-vision magnifier. 886.5540 Section 886.5540...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5540 Low-vision magnifier. (a) Identification. A low-vision magnifier is a device that consists of a magnifying lens intended for use by a patient...

  13. 21 CFR 886.5870 - Low-vision telescope.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Low-vision telescope. 886.5870 Section 886.5870...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5870 Low-vision telescope. (a) Identification. A low-vision telescope is a device that consists of an arrangement of lenses or mirrors intended for...

  14. What Aspects of Vision Facilitate Haptic Processing?

    ERIC Educational Resources Information Center

    Millar, Susanna; Al-Attar, Zainab

    2005-01-01

    We investigate how vision affects haptic performance when task-relevant visual cues are reduced or excluded. The task was to remember the spatial location of six landmarks that were explored by touch in a tactile map. Here, we use specially designed spectacles that simulate residual peripheral vision, tunnel vision, diffuse light perception, and…

  15. 21 CFR 886.5540 - Low-vision magnifier.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Low-vision magnifier. 886.5540 Section 886.5540...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5540 Low-vision magnifier. (a) Identification. A low-vision magnifier is a device that consists of a magnifying lens intended for use by a patient...

  16. 21 CFR 886.5870 - Low-vision telescope.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Low-vision telescope. 886.5870 Section 886.5870...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5870 Low-vision telescope. (a) Identification. A low-vision telescope is a device that consists of an arrangement of lenses or mirrors intended for...

  17. 21 CFR 886.5540 - Low-vision magnifier.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Low-vision magnifier. 886.5540 Section 886.5540...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5540 Low-vision magnifier. (a) Identification. A low-vision magnifier is a device that consists of a magnifying lens intended for use by a patient...

  18. 21 CFR 886.5870 - Low-vision telescope.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Low-vision telescope. 886.5870 Section 886.5870...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5870 Low-vision telescope. (a) Identification. A low-vision telescope is a device that consists of an arrangement of lenses or mirrors intended for...

  19. 49 CFR 393.80 - Rear-vision mirrors.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Rear-vision mirrors. 393.80 Section 393.80... NECESSARY FOR SAFE OPERATION Miscellaneous Parts and Accessories § 393.80 Rear-vision mirrors. (a) Every bus, truck, and truck tractor shall be equipped with two rear-vision mirrors, one at each side, firmly...

  20. 21 CFR 886.5915 - Optical vision aid.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Optical vision aid. 886.5915 Section 886.5915 Food... DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5915 Optical vision aid. (a) Identification. An optical vision aid is a device that consists of a magnifying lens with an accompanying AC-powered or...

  1. 49 CFR 393.80 - Rear-vision mirrors.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 5 2011-10-01 2011-10-01 false Rear-vision mirrors. 393.80 Section 393.80... NECESSARY FOR SAFE OPERATION Miscellaneous Parts and Accessories § 393.80 Rear-vision mirrors. (a) Every bus, truck, and truck tractor shall be equipped with two rear-vision mirrors, one at each side, firmly...

  2. 21 CFR 886.5915 - Optical vision aid.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Optical vision aid. 886.5915 Section 886.5915 Food... DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5915 Optical vision aid. (a) Identification. An optical vision aid is a device that consists of a magnifying lens with an accompanying AC-powered or...

  3. Vision Loss Following Episcleral Brachytherapy for Uveal Melanoma: Development of a Vision Prognostication Tool.

    PubMed

    Aziz, Hassan A; Singh, Nakul; Bena, James; Wilkinson, Allan; Singh, Arun D

    2016-06-01

    Vision loss following episcleral brachytherapy for uveal melanoma is difficult to predict for individual patients. To generate a risk calculator for vision loss following episcleral brachytherapy for uveal melanoma. A retrospective review of data was conducted at a multispecialty tertiary care center in Cleveland, Ohio. All patients with primary ciliary body or choroidal melanoma treated with iodine 125 or ruthenium 106 episcleral brachytherapy between January 1, 2004, and December 30, 2013, were included. Univariate and multivariable Cox proportional hazards were used to determine the influence of baseline patient factors on vision loss. Kaplan-Meier curves (log-rank analyses) were used to estimate freedom from vision loss. Bootstrap resampling was performed to bias correct this estimate. Vision loss (to visual acuity [VA] worse than 20/50 and worse than 20/200). A total of 311 patients were included in the study, with a mean (SD) age of 62 (14.7) years at start of treatment and a median follow-up of 36 months (interquartile range, 18-60 months). At presentation, VA was better than or equal to 20/50 in 199 patients (64%) and better than or equal to 20/200 in 289 patients (93%). By Kaplan-Meier analysis, VA less than 20/200 at 3 years was not associated with sex, diabetes, systemic hypertension, or hypercholesterolemia but was associated with history of ocular comorbidities, type of isotope (ruthenium 106 or iodine 125), and initial VA ( >20/50 or <20/50). By multivariable analysis, age (hazard ratio [HR], 0.97; 95% CI, 0.94-1.00; P = .06), largest basal diameter (HR, 1.25; 95% CI, 1.16-1.34; P = <.001), total radiation dose to the fovea (HR, 1.03; 95% CI, 1.01-1.04; P = .001) and optic disc (HR, 1.01; 95% CI, 1.00-1.01; P = .005), and initial VA worse than 20/50 (HR, 1.85; 95% CI, 1.20-2.85; P = .005) were predictive of vision loss to a VA of less than 20/200. The concordance index for the full data set was 0.77. Using these data, an online

  4. Putting the Vision into Practice

    ERIC Educational Resources Information Center

    Ravenhall, Mark

    2010-01-01

    It's almost a year since the revolution--the "Learning Revolution," that is. This was the Government's long-term vision for the development of "informal adult learning", as laid out in the White Paper of March 2009. The vision was expansive, embracing informal learning in the workplace, promoting a "new" culture of…

  5. Cross-Modal Correspondence Among Vision, Audition, and Touch in Natural Objects: An Investigation of the Perceptual Properties of Wood.

    PubMed

    Kanaya, Shoko; Kariya, Kenji; Fujisaki, Waka

    2016-10-01

    Certain systematic relationships are often assumed between information conveyed from multiple sensory modalities; for instance, a small figure and a high pitch may be perceived as more harmonious. This phenomenon, termed cross-modal correspondence, may result from correlations between multi-sensory signals learned in daily experience of the natural environment. If so, we would observe cross-modal correspondences not only in the perception of artificial stimuli but also in perception of natural objects. To test this hypothesis, we reanalyzed data collected previously in our laboratory examining perceptions of the material properties of wood using vision, audition, and touch. We compared participant evaluations of three perceptual properties (surface brightness, sharpness of sound, and smoothness) of the wood blocks obtained separately via vision, audition, and touch. Significant positive correlations were identified for all properties in the audition-touch comparison, and for two of the three properties regarding in the vision-touch comparison. By contrast, no properties exhibited significant positive correlations in the vision-audition comparison. These results suggest that we learn correlations between multi-sensory signals through experience; however, the strength of this statistical learning is apparently dependent on the particular combination of sensory modalities involved. © The Author(s) 2016.

  6. Integrated Energy System with Beneficial Carbon Dioxide (CO{sub 2}) Use

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, Xiaolei; Rink, Nancy

    2011-04-30

    To address the public concerns regarding the consequences of climate change from anthropogenic carbon dioxide (CO{sub 2}) emissions, the U.S. Department of Energy National Energy Technology Laboratory (DOE-NETL) is actively funding a CO{sub 2} management program to develop technologies capable of reducing the CO{sub 2} emissions from fossil fuel power plants and other industrial facilities. Over the past decade, this program has focused on reducing the costs of carbon capture and storage technologies. Recently, DOE-NETL launched an alternative CO{sub 2} mitigation program focusing on beneficial CO{sub 2} reuse and supporting the development of technologies that mitigate emissions by converting CO{submore » 2} to solid mineral form that can be utilized for enhanced oil recovery, in the manufacturing of concrete or as a benign landfill, in the production of valuable chemicals and/or fuels. This project was selected as a CO{sub 2} reuse activity which would conduct research and development (R&D) at the pilot scale via a cost-shared Cooperative Agreement number DE-FE0001099 with DOE-NETL and would utilize funds setaside by the American Recovery and Reinvestment Act (ARRA) of 2009 for Industrial Carbon Capture and Sequestration R&D,« less

  7. The fate of mercury in coal utilization byproducts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    William Aljoe; Thomas Feeley; James Murphy

    2005-05-01

    The US Department of Energy National Energy Technology Laboratory's (DOE/NETL's) research has helped to further scientific understanding of the environmental characteristics of coal-utilization by-products (CUBs) in both disposal and beneficial utilization applications. The following general observations can be drawn from results of the research that has been carried out to date: There appears to be only minimal mercury release to the environment in typical disposal or utilization applications for CUBs generated using activated carbon injection (ACI) control technologies; There appears to be only minimal mercury release to the environment in typical disposal and utilization applications for CUBs generated using wetmore » FGD control technologies. The potential release of mercury from wet FGD gypsum during the manufacture of wallboard is still under evaluation; The amount of mercury leached from CUB samples tested by DOE/NETL is significantly lower than the federal drinking water standards and water quality criteria for the protection of aquatic life; in many cases, leachate concentrations were below the standard test method detection limits. DOE/NETL will continue to partner with industry and other key stakeholders in carrying out research to better understand the fate of mercury and other trace elements in the byproducts from coal combustion. 16 refs., 6 tabs.« less

  8. The use of CellaVision competency software for external quality assessment and continuing professional development.

    PubMed

    Horiuchi, Yuki; Tabe, Yoko; Idei, Mayumi; Bengtsson, Hans-Inge; Ishii, Kiyoshi; Horii, Takashi; Miyake, Kazunori; Satoh, Naotake; Miida, Takashi; Ohsaka, Akimichi

    2011-07-01

    Quality assessment of blood cell morphological testing, such as white blood cell (WBC) differential and its interpretation, is one of the most important and difficult assignments in haematology laboratories. A monthly survey was performed to assess the possible role of the proficiency testing program produced by CellaVision competency software (CCS) in external quality assessment (EQA) of the clinical laboratories of affiliated university hospitals and the effective utilisation of this program in continuing professional development (CPD). Four monthly proficiency surveys were conducted in collaboration with four clinical laboratories affiliated with the teaching hospitals of Juntendo University of Medicine in Japan. EQA results by the CCS proficiency testing program revealed a difference of performance levels of WBC differential and morphological interpretation and a discrepancy in the WBC differential criteria among laboratories. With regard to the utilisation of this proficiency program as a tool for CPD, this program successfully improved the performance of the low-scoring laboratories and less experienced individuals. The CCS proficiency testing program was useful for the quality assessment of laboratory performance, for education, and for the storage and distribution of cell images to be utilised for further standardisation and education.

  9. Insect photoreceptor adaptations to night vision

    PubMed Central

    Honkanen, Anna; Salmela, Iikka; Weckström, Matti

    2017-01-01

    Night vision is ultimately about extracting information from a noisy visual input. Several species of nocturnal insects exhibit complex visually guided behaviour in conditions where most animals are practically blind. The compound eyes of nocturnal insects produce strong responses to single photons and process them into meaningful neural signals, which are amplified by specialized neuroanatomical structures. While a lot is known about the light responses and the anatomical structures that promote pooling of responses to increase sensitivity, there is still a dearth of knowledge on the physiology of night vision. Retinal photoreceptors form the first bottleneck for the transfer of visual information. In this review, we cover the basics of what is known about physiological adaptations of insect photoreceptors for low-light vision. We will also discuss major enigmas of some of the functional properties of nocturnal photoreceptors, and describe recent advances in methodologies that may help to solve them and broaden the field of insect vision research to new model animals. This article is part of the themed issue ‘Vision in dim light’. PMID:28193821

  10. Insect photoreceptor adaptations to night vision.

    PubMed

    Honkanen, Anna; Immonen, Esa-Ville; Salmela, Iikka; Heimonen, Kyösti; Weckström, Matti

    2017-04-05

    Night vision is ultimately about extracting information from a noisy visual input. Several species of nocturnal insects exhibit complex visually guided behaviour in conditions where most animals are practically blind. The compound eyes of nocturnal insects produce strong responses to single photons and process them into meaningful neural signals, which are amplified by specialized neuroanatomical structures. While a lot is known about the light responses and the anatomical structures that promote pooling of responses to increase sensitivity, there is still a dearth of knowledge on the physiology of night vision. Retinal photoreceptors form the first bottleneck for the transfer of visual information. In this review, we cover the basics of what is known about physiological adaptations of insect photoreceptors for low-light vision. We will also discuss major enigmas of some of the functional properties of nocturnal photoreceptors, and describe recent advances in methodologies that may help to solve them and broaden the field of insect vision research to new model animals.This article is part of the themed issue 'Vision in dim light'. © 2017 The Author(s).

  11. Integrated Imaging and Vision Techniques for Industrial Inspection: A Special Issue on Machine Vision and Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Zheng; Ukida, H.; Ramuhalli, Pradeep

    2010-06-05

    Imaging- and vision-based techniques play an important role in industrial inspection. The sophistication of the techniques assures high- quality performance of the manufacturing process through precise positioning, online monitoring, and real-time classification. Advanced systems incorporating multiple imaging and/or vision modalities provide robust solutions to complex situations and problems in industrial applications. A diverse range of industries, including aerospace, automotive, electronics, pharmaceutical, biomedical, semiconductor, and food/beverage, etc., have benefited from recent advances in multi-modal imaging, data fusion, and computer vision technologies. Many of the open problems in this context are in the general area of image analysis methodologies (preferably in anmore » automated fashion). This editorial article introduces a special issue of this journal highlighting recent advances and demonstrating the successful applications of integrated imaging and vision technologies in industrial inspection.« less

  12. The Impact of Vision in Spatial Coding

    ERIC Educational Resources Information Center

    Papadopoulos, Konstantinos; Koustriava, Eleni

    2011-01-01

    The aim of this study is to examine the performance in coding and representing of near-space in relation to vision status (blindness vs. normal vision) and sensory modality (touch vs. vision). Forty-eight children and teenagers participated. Sixteen of the participants were totally blind or had only light perception, 16 were blindfolded sighted…

  13. Leadership: Vision & Structure. Resource Paper No. 36.

    ERIC Educational Resources Information Center

    Groff, Warren H.

    Research indicates that leaders tend to be remarkably well-balanced people who embody four areas of competency: vision, the ability to communicate that vision, positive self-regard, and the ability to build trust with associates. The process of creating a vision of the future requires an understanding of the opportunities and threats present in…

  14. Management Matters. Nurture Your Vision

    ERIC Educational Resources Information Center

    Pappas, Marjorie L.

    2005-01-01

    In many professional roles, long-term vision may help guide short-term decisions. This is especially true for school library professionals as library media programs are constantly evolving. This author suggests strategies to assist library media specialists to nurture their vision and provides reviews of several sources and experts in the field…

  15. Color Vision Deficiency in Preschool Children

    PubMed Central

    Xie, John Z.; Tarczy-Hornoch, Kristina; Lin, Jesse; Cotter, Susan A.; Torres, Mina; Varma, Rohit

    2016-01-01

    Purpose To determine the sex- and ethnicity-specific prevalence of color vision deficiency (CVD) in black, Asian, Hispanic, and non-Hispanic white preschool children. Design Population-based, cross-sectional study. Participants The Multi-Ethnic Pediatric Eye Disease Study is a population-based evaluation of the prevalence of vision disorders in children in Southern California. A total of 5960 subjects 30 to 72 months of age were recruited for the study, of whom 4177 were able to complete color vision testing (1265 black, 812 Asian, 1280 Hispanic, and 820 non-Hispanic white). Methods Color vision testing was performed using Color Vision Testing Made Easy color plates (Home Vision Care, Gulf Breeze, FL), and diagnostic confirmatory testing was performed using the Waggoner HRR Diagnostic Test color plates (Home Vision Care). Main Outcome Measures Testability of color vision in preschool children between 30 and 72 months of age and prevalence of CVD stratified by age, sex, and ethnicity. Results Testability was 17% in children younger than 37 months of age, increasing to 57% in children 37 to 48 months of age, 89% in children 49 to 60 months of age, and 98% in children 61 to 72 months of age. The prevalence of CVD among boys was 1.4% for black, 3.1% for Asian, 2.6% for Hispanic, and 5.6% for non-Hispanic white children; the prevalence in girls was 0.0% to 0.5% for all ethnicities. The ethnic difference in CVD was statistically significant between black and non-Hispanic white children (P = 0.0003) and between Hispanic and non-Hispanic white children (P = 0.02). In boys, most CVD cases were either deutan (51%) or protan (34%); 32% were classified as mild, 15% as moderate, and 41% as severe. Conclusions Testability for CVD in preschool children is high by 4 years of age. The prevalence of CVD in preschool boys varies by ethnicity, with the highest prevalence in non-Hispanic white and lowest in black children. PMID:24702753

  16. Topographic Mapping of Residual Vision by Computer

    ERIC Educational Resources Information Center

    MacKeben, Manfred

    2008-01-01

    Many persons with low vision have diseases that damage the retina only in selected areas, which can lead to scotomas (blind spots) in perception. The most frequent of these diseases is age-related macular degeneration (AMD), in which foveal vision is often impaired by a central scotoma that impairs vision of fine detail and causes problems with…

  17. Coaching Peripheral Vision Training for Soccer Athletes

    ERIC Educational Resources Information Center

    Marques, Nelson Kautzner, Jr.

    2010-01-01

    Brazilian Soccer began developing its current emphasis on peripheral vision in the late 1950s, by initiative of coach of the Canto do Rio Football Club, in Niteroi, Rio de Janeiro, a pioneer in the development of peripheral vision training in soccer players. Peripheral vision training gained world relevance when a young talent from Canto do Rio,…

  18. The Adaptive Optics Summer School Laboratory Activities

    NASA Astrophysics Data System (ADS)

    Ammons, S. M.; Severson, S.; Armstrong, J. D.; Crossfield, I.; Do, T.; Fitzgerald, M.; Harrington, D.; Hickenbotham, A.; Hunter, J.; Johnson, J.; Johnson, L.; Li, K.; Lu, J.; Maness, H.; Morzinski, K.; Norton, A.; Putnam, N.; Roorda, A.; Rossi, E.; Yelda, S.

    2010-12-01

    Adaptive Optics (AO) is a new and rapidly expanding field of instrumentation, yet astronomers, vision scientists, and general AO practitioners are largely unfamiliar with the root technologies crucial to AO systems. The AO Summer School (AOSS), sponsored by the Center for Adaptive Optics, is a week-long course for training graduate students and postdoctoral researchers in the underlying theory, design, and use of AO systems. AOSS participants include astronomers who expect to utilize AO data, vision scientists who will use AO instruments to conduct research, opticians and engineers who design AO systems, and users of high-bandwidth laser communication systems. In this article we describe new AOSS laboratory sessions implemented in 2006-2009 for nearly 250 students. The activity goals include boosting familiarity with AO technologies, reinforcing knowledge of optical alignment techniques and the design of optical systems, and encouraging inquiry into critical scientific questions in vision science using AO systems as a research tool. The activities are divided into three stations: Vision Science, Fourier Optics, and the AO Demonstrator. We briefly overview these activities, which are described fully in other articles in these conference proceedings (Putnam et al., Do et al., and Harrington et al., respectively). We devote attention to the unique challenges encountered in the design of these activities, including the marriage of inquiry-like investigation techniques with complex content and the need to tune depth to a graduate- and PhD-level audience. According to before-after surveys conducted in 2008, the vast majority of participants found that all activities were valuable to their careers, although direct experience with integrated, functional AO systems was particularly beneficial.

  19. Understanding Your Vision: The "Imperfect Eye"

    MedlinePlus

    ... including peripheral awareness (side vision), eye coordination, depth perception, focusing ability, and color vision that make up ... the conditions for which you may be at risk." — Dr. Emily Chew National Eye Institute Farsighted If ...

  20. Limits of colour vision in dim light.

    PubMed

    Kelber, Almut; Lind, Olle

    2010-09-01

    Humans and most vertebrates have duplex retinae with multiple cone types for colour vision in bright light, and one single rod type for achromatic vision in dim light. Instead of comparing signals from multiple spectral types of photoreceptors, such species use one highly sensitive receptor type thus improving the signal-to-noise ratio at night. However, the nocturnal hawkmoth Deilephila elpenor, the nocturnal bee Xylocopa tranquebarica and the nocturnal gecko Tarentola chazaliae can discriminate colours at extremely dim light intensities. To be able to do so, they sacrifice spatial and temporal resolution in favour of colour vision. We review what is known about colour vision in dim light, and compare colour vision thresholds with the optical sensitivity of the photoreceptors in selected animal species with lens and compound eyes. © 2010 The Authors, Ophthalmic and Physiological Optics © 2010 The College of Optometrists.

  1. Ultra-Rapid Vision in Birds.

    PubMed

    Boström, Jannika E; Dimitrova, Marina; Canton, Cindy; Håstad, Olle; Qvarnström, Anna; Ödeen, Anders

    2016-01-01

    Flying animals need to accurately detect, identify and track fast-moving objects and these behavioral requirements are likely to strongly select for abilities to resolve visual detail in time. However, evidence of highly elevated temporal acuity relative to non-flying animals has so far been confined to insects while it has been missing in birds. With behavioral experiments on three wild passerine species, blue tits, collared and pied flycatchers, we demonstrate temporal acuities of vision far exceeding predictions based on the sizes and metabolic rates of these birds. This implies a history of strong natural selection on temporal resolution. These birds can resolve alternating light-dark cycles at up to 145 Hz (average: 129, 127 and 137, respectively), which is ca. 50 Hz over the highest frequency shown in any other vertebrate. We argue that rapid vision should confer a selective advantage in many bird species that are ecologically similar to the three species examined in our study. Thus, rapid vision may be a more typical avian trait than the famously sharp vision found in birds of prey.

  2. Vision training methods for sports concussion mitigation and management.

    PubMed

    Clark, Joseph F; Colosimo, Angelo; Ellis, James K; Mangine, Robert; Bixenmann, Benjamin; Hasselfeld, Kimberly; Graman, Patricia; Elgendy, Hagar; Myer, Gregory; Divine, Jon

    2015-05-05

    There is emerging evidence supporting the use vision training, including light board training tools, as a concussion baseline and neuro-diagnostic tool and potentially as a supportive component to concussion prevention strategies. This paper is focused on providing detailed methods for select vision training tools and reporting normative data for comparison when vision training is a part of a sports management program. The overall program includes standard vision training methods including tachistoscope, Brock's string, and strobe glasses, as well as specialized light board training algorithms. Stereopsis is measured as a means to monitor vision training affects. In addition, quantitative results for vision training methods as well as baseline and post-testing *A and Reaction Test measures with progressive scores are reported. Collegiate athletes consistently improve after six weeks of training in their stereopsis, *A and Reaction Test scores. When vision training is initiated as a team wide exercise, the incidence of concussion decreases in players who participate in training compared to players who do not receive the vision training. Vision training produces functional and performance changes that, when monitored, can be used to assess the success of the vision training and can be initiated as part of a sports medical intervention for concussion prevention.

  3. Vision Training Methods for Sports Concussion Mitigation and Management

    PubMed Central

    Clark, Joseph F.; Colosimo, Angelo; Ellis, James K.; Mangine, Robert; Bixenmann, Benjamin; Hasselfeld, Kimberly; Graman, Patricia; Elgendy, Hagar; Myer, Gregory; Divine, Jon

    2015-01-01

    There is emerging evidence supporting the use vision training, including light board training tools, as a concussion baseline and neuro-diagnostic tool and potentially as a supportive component to concussion prevention strategies. This paper is focused on providing detailed methods for select vision training tools and reporting normative data for comparison when vision training is a part of a sports management program. The overall program includes standard vision training methods including tachistoscope, Brock’s string, and strobe glasses, as well as specialized light board training algorithms. Stereopsis is measured as a means to monitor vision training affects. In addition, quantitative results for vision training methods as well as baseline and post-testing *A and Reaction Test measures with progressive scores are reported. Collegiate athletes consistently improve after six weeks of training in their stereopsis, *A and Reaction Test scores. When vision training is initiated as a team wide exercise, the incidence of concussion decreases in players who participate in training compared to players who do not receive the vision training. Vision training produces functional and performance changes that, when monitored, can be used to assess the success of the vision training and can be initiated as part of a sports medical intervention for concussion prevention. PMID:25992878

  4. The genetics of normal and defective color vision

    PubMed Central

    Neitz, Jay; Neitz, Maureen

    2011-01-01

    The contributions of genetics research to the science of normal and defective color vision over the previous few decades are reviewed emphasizing the developments in the 25 years since the last anniversary issue of Vision Research. Understanding of the biology underlying color vision has been vaulted forward through the application of the tools of molecular genetics. For all their complexity, the biological processes responsible for color vision are more accessible than for many other neural systems. This is partly because of the wealth of genetic variations that affect color perception, both within and across species, and because components of the color vision system lend themselves to genetic manipulation. Mutations and rearrangements in the genes encoding the long, middle, and short wavelength sensitive cone pigments are responsible for color vision deficiencies and mutations have been identified that affect the number of cone types, the absorption spectrum of the pigments, the functionality and viability of the cones, and the topography of the cone mosaic. The addition of an opsin gene, as occurred in the evolution of primate color vision, and has been done in experimental animals can produce expanded color vision capacities and this has provided insight into the underlying neural circuitry. PMID:21167193

  5. The genetics of normal and defective color vision.

    PubMed

    Neitz, Jay; Neitz, Maureen

    2011-04-13

    The contributions of genetics research to the science of normal and defective color vision over the previous few decades are reviewed emphasizing the developments in the 25years since the last anniversary issue of Vision Research. Understanding of the biology underlying color vision has been vaulted forward through the application of the tools of molecular genetics. For all their complexity, the biological processes responsible for color vision are more accessible than for many other neural systems. This is partly because of the wealth of genetic variations that affect color perception, both within and across species, and because components of the color vision system lend themselves to genetic manipulation. Mutations and rearrangements in the genes encoding the long, middle, and short wavelength sensitive cone pigments are responsible for color vision deficiencies and mutations have been identified that affect the number of cone types, the absorption spectra of the pigments, the functionality and viability of the cones, and the topography of the cone mosaic. The addition of an opsin gene, as occurred in the evolution of primate color vision, and has been done in experimental animals can produce expanded color vision capacities and this has provided insight into the underlying neural circuitry. Copyright © 2010 Elsevier Ltd. All rights reserved.

  6. Machine Vision Giving Eyes to Robots. Resources in Technology.

    ERIC Educational Resources Information Center

    Technology Teacher, 1990

    1990-01-01

    This module introduces machine vision, which can be used for inspection, robot guidance and part sorting. The future for machine vision will include new technology and will bring vision systems closer to the ultimate vision processor, the human eye. Includes a student quiz, outcomes, and activities. (JOW)

  7. FY 2009 National Renewable Energy Laboratory (NREL) Annual Report: A Year of Energy Transformation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2010-01-01

    This FY2009 Annual Report surveys the National Renewable Energy Laboratory's (NREL) accomplishments in renewable energy and energy efficiency research and development, commercialization and deployment of technologies, and strategic energy analysis. It offers NREL's vision and progress in building a clean, sustainable research campus and reports on community involvement.

  8. Vision Problems: How Teachers Can Help.

    ERIC Educational Resources Information Center

    Desrochers, Joyce

    1999-01-01

    Describes common vision problems in young children such as myopia, strabismus, and amblyopia. Presents suggestions for helping children with vision problems in the early childhood classroom and in outdoor activities. Lists related resources and children's books. (KB)

  9. Illumination-based synchronization of high-speed vision sensors.

    PubMed

    Hou, Lei; Kagami, Shingo; Hashimoto, Koichi

    2010-01-01

    To acquire images of dynamic scenes from multiple points of view simultaneously, the acquisition time of vision sensors should be synchronized. This paper describes an illumination-based synchronization method derived from the phase-locked loop (PLL) algorithm. Incident light to a vision sensor from an intensity-modulated illumination source serves as the reference signal for synchronization. Analog and digital computation within the vision sensor forms a PLL to regulate the output signal, which corresponds to the vision frame timing, to be synchronized with the reference. Simulated and experimental results show that a 1,000 Hz frame rate vision sensor was successfully synchronized with 32 μs jitters.

  10. Stereoacuity of preschool children with and without vision disorders.

    PubMed

    Ciner, Elise B; Ying, Gui-Shuang; Kulp, Marjean Taylor; Maguire, Maureen G; Quinn, Graham E; Orel-Bixler, Deborah; Cyert, Lynn A; Moore, Bruce; Huang, Jiayan

    2014-03-01

    To evaluate associations between stereoacuity and presence, type, and severity of vision disorders in Head Start preschool children and determine testability and levels of stereoacuity by age in children without vision disorders. Stereoacuity of children aged 3 to 5 years (n = 2898) participating in the Vision in Preschoolers (VIP) Study was evaluated using the Stereo Smile II test during a comprehensive vision examination. This test uses a two-alternative forced-choice paradigm with four stereoacuity levels (480 to 60 seconds of arc). Children were classified by the presence (n = 871) or absence (n = 2027) of VIP Study-targeted vision disorders (amblyopia, strabismus, significant refractive error, or unexplained reduced visual acuity), including type and severity. Median stereoacuity between groups and among severity levels of vision disorders was compared using Wilcoxon rank sum and Kruskal-Wallis tests. Testability and stereoacuity levels were determined for children without VIP Study-targeted disorders overall and by age. Children with VIP Study-targeted vision disorders had significantly worse median stereoacuity than that of children without vision disorders (120 vs. 60 seconds of arc, p < 0.001). Children with the most severe vision disorders had worse stereoacuity than that of children with milder disorders (median 480 vs. 120 seconds of arc, p < 0.001). Among children without vision disorders, testability was 99.6% overall, increasing with age to 100% for 5-year-olds (p = 0.002). Most of the children without vision disorders (88%) had stereoacuity at the two best disparities (60 or 120 seconds of arc); the percentage increasing with age (82% for 3-, 89% for 4-, and 92% for 5-year-olds; p < 0.001). The presence of any VIP Study-targeted vision disorder was associated with significantly worse stereoacuity in preschool children. Severe vision disorders were more likely associated with poorer stereopsis than milder or no vision disorders. Testability was

  11. A Grand Vision for European Astronomy

    NASA Astrophysics Data System (ADS)

    2007-09-01

    Today, and for the first time, astronomers share their global Science Vision for European Astronomy in the next two decades. This two-year long effort by the ASTRONET network of funding agencies, sponsored by the European Commission and coordinated by INSU-CNRS, underscores Europe's ascension to world leadership in astronomy and its will to maintain that position. It will be followed in just over a year by a prioritised roadmap for the observational facilities needed to implement the Vision. Implementation of these plans will ensure that Europe fully contributes to Mankind's ever deeper understanding of the wonders of our Universe. astronet logo "This is a great opportunity to help create a vibrant long-term future for astronomy and science" says Tim de Zeeuw (Leiden Observatory, The Netherlands) who led this community-wide effort. The ASTRONET Science Vision provides a comprehensive overview of the most important scientific questions that European astronomy should address in the next twenty years. The four key questions are the extremes of the Universe, from the nature of the dark matter and dark energy that comprise over 95% of the Universe to the physics of extreme objects such as black holes, neutron stars, and gamma-ray bursts; the formation of galaxies from the first seeds to our Milky Way; the formation of stars and planets and the origin of life; and the crucial question of how do we (and our Solar System) fit in the global picture. These themes reach well beyond the realm of traditional astronomy into the frontiers of physics and biology. The Vision identifies the major new facilities that will be needed to achieve these goals, but also stresses the need for parallel developments in theory and numerical simulations, high-performance computing resources, efficient astronomical data archiving and the European Virtual Observatory, as well as in laboratory astrophysics. "This report is a key input for the even more challenging task of developing a prioritised

  12. Indoor Spatial Updating With Impaired Vision

    PubMed Central

    Legge, Gordon E.; Granquist, Christina; Baek, Yihwa; Gage, Rachel

    2016-01-01

    Purpose Spatial updating is the ability to keep track of position and orientation while moving through an environment. We asked how normally sighted and visually impaired subjects compare in spatial updating and in estimating room dimensions. Methods Groups of 32 normally sighted, 16 low-vision, and 16 blind subjects estimated the dimensions of six rectangular rooms. Updating was assessed by guiding the subjects along three-segment paths in the rooms. At the end of each path, they estimated the distance and direction to the starting location, and to a designated target. Spatial updating was tested in five conditions ranging from free viewing to full auditory and visual deprivation. Results The normally sighted and low-vision groups did not differ in their accuracy for judging room dimensions. Correlations between estimated size and physical size were high. Accuracy of low-vision performance was not correlated with acuity, contrast sensitivity, or field status. Accuracy was lower for the blind subjects. The three groups were very similar in spatial-updating performance, and exhibited only weak dependence on the nature of the viewing conditions. Conclusions People with a wide range of low-vision conditions are able to judge room dimensions as accurately as people with normal vision. Blind subjects have difficulty in judging the dimensions of quiet rooms, but some information is available from echolocation. Vision status has little impact on performance in simple spatial updating; proprioceptive and vestibular cues are sufficient. PMID:27978556

  13. Indoor Spatial Updating With Impaired Vision.

    PubMed

    Legge, Gordon E; Granquist, Christina; Baek, Yihwa; Gage, Rachel

    2016-12-01

    Spatial updating is the ability to keep track of position and orientation while moving through an environment. We asked how normally sighted and visually impaired subjects compare in spatial updating and in estimating room dimensions. Groups of 32 normally sighted, 16 low-vision, and 16 blind subjects estimated the dimensions of six rectangular rooms. Updating was assessed by guiding the subjects along three-segment paths in the rooms. At the end of each path, they estimated the distance and direction to the starting location, and to a designated target. Spatial updating was tested in five conditions ranging from free viewing to full auditory and visual deprivation. The normally sighted and low-vision groups did not differ in their accuracy for judging room dimensions. Correlations between estimated size and physical size were high. Accuracy of low-vision performance was not correlated with acuity, contrast sensitivity, or field status. Accuracy was lower for the blind subjects. The three groups were very similar in spatial-updating performance, and exhibited only weak dependence on the nature of the viewing conditions. People with a wide range of low-vision conditions are able to judge room dimensions as accurately as people with normal vision. Blind subjects have difficulty in judging the dimensions of quiet rooms, but some information is available from echolocation. Vision status has little impact on performance in simple spatial updating; proprioceptive and vestibular cues are sufficient.

  14. [Ophthalmologist and "computer vision syndrome"].

    PubMed

    Barar, A; Apatachioaie, Ioana Daniela; Apatachioaie, C; Marceanu-Brasov, L

    2007-01-01

    The authors had tried to collect the data available on the Internet about a subject that we consider as being totally ignored in the Romanian scientific literature and unexpectedly insufficiently treated in the specialized ophthalmologic literature. Known in the specialty literature under the generic name of "Computer vision syndrome", it is defined by the American Optometric Association as a complex of eye and vision problems related to the activities which stress the near vision and which are experienced in relation, or during, the use of the computer. During the consultations we hear frequent complaints of eye-strain - asthenopia, headaches, blurred distance and/or near vision, dry and irritated eyes, slow refocusing, neck and backache, photophobia, sensation of diplopia, light sensitivity, and double vision, but because of the lack of information, we overlooked them too easily, without going thoroughly into the real motives. In most of the developed countries, there are recommendations issued by renowned medical associations with regard to the definition, the diagnosis, and the methods for the prevention, treatment and periodical control of the symptoms found in computer users, in conjunction with an extremely detailed ergonomic legislation. We found out that these problems incite a much too low interest in our country. We would like to rouse the interest of our ophthalmologist colleagues in the understanding and the recognition of these symptoms and in their treatment, or at least their improvement, through specialized measures or through the cooperation with our specialist occupational medicine colleagues.

  15. Mini-review: Far peripheral vision.

    PubMed

    Simpson, Michael J

    2017-11-01

    The region of far peripheral vision, beyond 60 degrees of visual angle, is important to the evaluation of peripheral dark shadows (negative dysphotopsia) seen by some intraocular lens (IOL) patients. Theoretical calculations show that the limited diameter of an IOL affects ray paths at large angles, leading to a dimming of the main image for small pupils, and to peripheral illumination by light bypassing the IOL for larger pupils. These effects are rarely bothersome, and cataract surgery is highly successful, but there is a need to improve the characterization of far peripheral vision, for both pseudophakic and phakic eyes. Perimetry is the main quantitative test, but the purpose is to evaluate pathologies rather than characterize vision (and object and image regions are no longer uniquely related in the pseudophakic eye). The maximum visual angle is approximately 105 0 , but there is limited information about variations with age, race, or refractive error (in case there is an unexpected link with the development of myopia), or about how clear cornea, iris location, and the limiting retina are related. Also, the detection of peripheral motion is widely recognized to be important, yet rarely evaluated. Overall, people rarely complain specifically about this visual region, but with "normal" vision including an IOL for >5% of people, and increasing interest in virtual reality and augmented reality, there are new reasons to characterize peripheral vision more completely. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. A Vision for Ice Giant Exploration

    NASA Technical Reports Server (NTRS)

    Hofstadter, M.; Simon, A.; Atreya, S.; Banfield, D.; Fortney, J.; Hayes, A.; Hedman, M.; Hospodarsky, G.; Mandt, K.; Masters, A.; hide

    2017-01-01

    From Voyager to a Vision for 2050: NASA and ESA have just completed a study of candidate missionsto Uranus and Neptune, the so-called ice giant planets. It is a Pre-Decadal Survey Study, meant to inform the next Planetary Science Decadal Survey about opportunities for missions launching in the 2020's and early 2030's. There have been no space flight missions to the ice giants since the Voyager 2 flybys of Uranus in 1986 and Neptune in 1989. This paper presents some conclusions of that study (hereafter referred to as The Study), and how the results feed into a vision for where planetary science can be in 2050. Reaching that vision will require investments in technology andground-based science in the 2020's, flight during the 2030's along with continued technological development of both ground- and space-based capabilities, and data analysis and additional flights in the 2040's. We first discuss why exploring the ice giants is important. We then summarize the science objectives identified by The Study, and our vision of the science goals for 2050. We then review some of the technologies needed to make this vision a reality.

  17. Analog "neuronal" networks in early vision.

    PubMed Central

    Koch, C; Marroquin, J; Yuille, A

    1986-01-01

    Many problems in early vision can be formulated in terms of minimizing a cost function. Examples are shape from shading, edge detection, motion analysis, structure from motion, and surface interpolation. As shown by Poggio and Koch [Poggio, T. & Koch, C. (1985) Proc. R. Soc. London, Ser. B 226, 303-323], quadratic variational problems, an important subset of early vision tasks, can be "solved" by linear, analog electrical, or chemical networks. However, in the presence of discontinuities, the cost function is nonquadratic, raising the question of designing efficient algorithms for computing the optimal solution. Recently, Hopfield and Tank [Hopfield, J. J. & Tank, D. W. (1985) Biol. Cybern. 52, 141-152] have shown that networks of nonlinear analog "neurons" can be effective in computing the solution of optimization problems. We show how these networks can be generalized to solve the nonconvex energy functionals of early vision. We illustrate this approach by implementing a specific analog network, solving the problem of reconstructing a smooth surface from sparse data while preserving its discontinuities. These results suggest a novel computational strategy for solving early vision problems in both biological and real-time artificial vision systems. PMID:3459172

  18. Visual evoked potentials through night vision goggles.

    PubMed

    Rabin, J

    1994-04-01

    Night vision goggles (NVG's) have widespread use in military and civilian environments. NVG's amplify ambient illumination making performance possible when there is insufficient illumination for normal vision. While visual performance through NVG's is commonly assessed by measuring threshold functions such as visual acuity, few attempts have been made to assess vision through NVG's at suprathreshold levels of stimulation. Such information would be useful to better understand vision through NVG's across a range of stimulus conditions. In this study visual evoked potentials (VEP's) were used to evaluate vision through NVG's across a range of stimulus contrasts. The amplitude and latency of the VEP varied linearly with log contrast. A comparison of VEP's recorded with and without NVG's was used to estimate contrast attenuation through the device. VEP's offer an objective, electrophysiological tool to assess visual performance through NVG's at both threshold and suprathreshold levels of visual stimulation.

  19. The effect of Medicaid adult vision coverage on the likelihood of appropriate correction of distance vision: Evidence from the National Health and Nutrition Examination Survey.

    PubMed

    Lipton, Brandy J; Decker, Sandra L

    2016-02-01

    Medicaid is the main public health insurance program for individuals with low income in the United States. Some state Medicaid programs cover preventive eye care services and vision correction, while others cover emergency eye care only. Similar to other optional benefits, states may add and drop adult vision benefits over time. This article examines whether providing adult vision benefits is associated with an increase in the percentage of low-income individuals with appropriately corrected distance vision as measured during an eye exam. We estimate the effect of Medicaid vision coverage on the likelihood of having appropriately corrected distance vision using examination data from the 2001-2008 National Health and Nutrition Examination Survey. We compare vision outcomes for Medicaid beneficiaries (n = 712) and other low income adults not enrolled in Medicaid (n = 4786) before and after changes to state vision coverage policies. Between 29 and 33 states provided Medicaid adult vision benefits during 2001-2008, depending on the year. Our findings imply that Medicaid adult vision coverage is associated with a significant increase in the percentage of Medicaid beneficiaries with appropriately corrected distance vision of up to 10 percentage points. Providing vision coverage to adults on Medicaid significantly increases the likelihood of appropriate correction of distance vision. Further research on the impact of vision coverage on related functional outcomes and the effects of Medicaid coverage of other services may be appropriate. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Insights into Inpatients with Poor Vision: A High Value Proposition

    PubMed Central

    Press, Valerie G.; Matthiesen, Madeleine I.; Ranadive, Alisha; Hariprasad, Seenu M.; Meltzer, David O.; Arora, Vineet M.

    2015-01-01

    Background Vision impairment is an under-recognized risk factor for adverse events among hospitalized patients, yet vision is neither routinely tested nor documented for inpatients. Low-cost ($8 and up) non-prescription ‘readers’ may be a simple, high-value intervention to improve inpatients’ vision. We aimed to study initial feasibility and efficacy of screening and correcting inpatients’ vision. Methods From June 2012 through January 2014 we began testing whether participants’ vision corrected with non-prescription lenses for eligible participants failing a vision screen (Snellen chart) performed by research assistants (RAs). Descriptive statistics and tests of comparison, including t-tests and chi-squared tests, were used when appropriate. All analyses were performed using Stata version 12 (StataCorps, College Station, TX). Results Over 800 participants’ vision was screened (n=853). Older (≥65 years; 56%) participants were more likely to have insufficient vision than younger (<65 years; 28%; p<0.001). Non-prescription readers corrected the majority of eligible participants’ vision (82%, 95/116). Discussion Among an easily identified sub-group of inpatients with poor vision, low-cost ‘readers’ successfully corrected most participants’ vision. Hospitalists and other clinicians working in the inpatient setting can play an important role in identifying opportunities to provide high-value care related to patients’ vision. PMID:25755206

  1. Research on an autonomous vision-guided helicopter

    NASA Technical Reports Server (NTRS)

    Amidi, Omead; Mesaki, Yuji; Kanade, Takeo

    1994-01-01

    Integration of computer vision with on-board sensors to autonomously fly helicopters was researched. The key components developed were custom designed vision processing hardware and an indoor testbed. The custom designed hardware provided flexible integration of on-board sensors with real-time image processing resulting in a significant improvement in vision-based state estimation. The indoor testbed provided convenient calibrated experimentation in constructing real autonomous systems.

  2. Prioritizing improvements to truck driver vision.

    DOT National Transportation Integrated Search

    2006-03-01

    This report presents the results of a three-part study of truck driver exterior vision and its safety consequences. In part one, : crash data are analyzed to document vision-related truck crash issues. About 20% of truck-initiated crashes occur in : ...

  3. Genetics Home Reference: color vision deficiency

    MedlinePlus

    ... PROTAN SERIES TRITANOPIA Sources for This Page Deeb SS. Molecular genetics of color-vision deficiencies. Vis Neurosci. 2004 May-Jun;21(3):191-6. Review. Citation on PubMed Deeb SS. The molecular basis of variation in human color vision. Clin ...

  4. Evaluation of functional color vision requirements and current color vision screening tests for air traffic control specialists.

    DOT National Transportation Integrated Search

    1990-08-01

    An experiment was conducted to evaluate the relation of type and degree of color vision deficiency and aeromedical color vision screening test scores to performance of color-dependent tasks of Air Traffic Control Specialists. The subjects included 37...

  5. An overview of computer vision

    NASA Technical Reports Server (NTRS)

    Gevarter, W. B.

    1982-01-01

    An overview of computer vision is provided. Image understanding and scene analysis are emphasized, and pertinent aspects of pattern recognition are treated. The basic approach to computer vision systems, the techniques utilized, applications, the current existing systems and state-of-the-art issues and research requirements, who is doing it and who is funding it, and future trends and expectations are reviewed.

  6. Vision in high-level football officials.

    PubMed

    Baptista, António Manuel Gonçalves; Serra, Pedro M; McAlinden, Colm; Barrett, Brendan T

    2017-01-01

    Officiating in football depends, at least to some extent, upon adequate visual function. However, there is no vision standard for football officiating and the nature of the relationship between officiating performance and level of vision is unknown. As a first step in characterising this relationship, we report on the clinically-measured vision and on the perceived level of vision in elite-level, Portuguese football officials. Seventy-one referees (R) and assistant referees (AR) participated in the study, representing 92% of the total population of elite level football officials in Portugal in the 2013/2014 season. Nine of the 22 Rs (40.9%) and ten of the 49 ARs (20.4%) were international-level. Information about visual history was also gathered. Perceived vision was assessed using the preference-values-assigned-to-global-visual-status (PVVS) and the Quality-of-Vision (QoV) questionnaire. Standard clinical vision measures (including visual acuity, contrast sensitivity and stereopsis) were gathered in a subset (n = 44, 62%) of the participants. Data were analysed according to the type (R/AR) and level (international/national) of official, and Bonferroni corrections were applied to reduce the risk of type I errors. Adopting criterion for statistical significance of p<0.01, PVVS scores did not differ between R and AR (p = 0.88), or between national- and international-level officials (p = 0.66). Similarly, QoV scores did not differ between R and AR in frequency (p = 0.50), severity (p = 0.71) or bothersomeness (p = 0.81) of symptoms, or between international-level vs national-level officials for frequency (p = 0.03) or bothersomeness (p = 0.07) of symptoms. However, international-level officials reported less severe symptoms than their national-level counterparts (p<0.01). Overall, 18.3% of officials had either never had an eye examination or if they had, it was more than 3 years previously. Regarding refractive correction, 4.2% had undergone refractive surgery and 23

  7. Vision in high-level football officials

    PubMed Central

    Serra, Pedro M.; McAlinden, Colm; Barrett, Brendan T.

    2017-01-01

    Officiating in football depends, at least to some extent, upon adequate visual function. However, there is no vision standard for football officiating and the nature of the relationship between officiating performance and level of vision is unknown. As a first step in characterising this relationship, we report on the clinically-measured vision and on the perceived level of vision in elite-level, Portuguese football officials. Seventy-one referees (R) and assistant referees (AR) participated in the study, representing 92% of the total population of elite level football officials in Portugal in the 2013/2014 season. Nine of the 22 Rs (40.9%) and ten of the 49 ARs (20.4%) were international-level. Information about visual history was also gathered. Perceived vision was assessed using the preference-values-assigned-to-global-visual-status (PVVS) and the Quality-of-Vision (QoV) questionnaire. Standard clinical vision measures (including visual acuity, contrast sensitivity and stereopsis) were gathered in a subset (n = 44, 62%) of the participants. Data were analysed according to the type (R/AR) and level (international/national) of official, and Bonferroni corrections were applied to reduce the risk of type I errors. Adopting criterion for statistical significance of p<0.01, PVVS scores did not differ between R and AR (p = 0.88), or between national- and international-level officials (p = 0.66). Similarly, QoV scores did not differ between R and AR in frequency (p = 0.50), severity (p = 0.71) or bothersomeness (p = 0.81) of symptoms, or between international-level vs national-level officials for frequency (p = 0.03) or bothersomeness (p = 0.07) of symptoms. However, international-level officials reported less severe symptoms than their national-level counterparts (p<0.01). Overall, 18.3% of officials had either never had an eye examination or if they had, it was more than 3 years previously. Regarding refractive correction, 4.2% had undergone refractive surgery and 23

  8. Data Report for Monitoring at Six West Virginia Marcellus Shale Development Sites using NETL’s Mobile Air Monitoring Laboratory (July–November 2012)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pekney, Natalie J.; Reeder, Matthew; Veloski, Garret A.

    The West Virginia Department of Environmental Protection’s Office of Oil and Gas was directed according to the Natural Gas Horizontal Well Control Act of December 14, 2011 (West Virginia Code §22-6A) to conduct studies of horizontal well drilling activities related to air quality. The planned study, “Noise, Light, Dust, Volatile Organic Compounds Related to Well Location Restrictions,” required determination of the effectiveness of a 625 ft minimum set-back from the center of the pad of a horizontal well drilling site to the nearest occupied dwelling. An investigation was conducted at seven drilling sites by West Virginia University (WVU) and themore » National Energy Technology Laboratory (NETL) to collect data on dust, hydrocarbon compounds and on noise, radiation, and light levels. NETL’s role in this study was to collect measurements of ambient pollutant concentrations at six of the seven selected sites using NETL’s Mobile Air Monitoring Laboratory. The trailer-based laboratory was situated a distance of 492–1,312 ft from each well pad, on which activities included well pad construction, vertical drilling, horizontal drilling, hydraulic fracturing, and flaring, with the objective of evaluating the air quality impact of each activity for 1–4 weeks per site. Measured pollutants included volatile organic compounds (VOCs), coarse and fine particulate matter (PM 10 and PM 2.5, respectively), ozone, methane (CH 4), carbon dioxide (CO 2), carbon isotopes of CH 4 and CO 2, organic carbon (OC), elemental carbon (EC), oxides of nitrogen (NOx), and sulfur dioxide (SO 2).« less

  9. Optoelectronic vision

    NASA Astrophysics Data System (ADS)

    Ren, Chunye; Parel, Jean-Marie A.

    1993-06-01

    Scientists have searched every discipline to find effective methods of treating blindness, such as using aids based on conversion of the optical image, to auditory or tactile stimuli. However, the limited performance of such equipment and difficulties in training patients have seriously hampered practical applications. A great edification has been given by the discovery of Foerster (1929) and Krause & Schum (1931), who found that the electrical stimulation of the visual cortex evokes the perception of a small spot of light called `phosphene' in both blind and sighted subjects. According to this principle, it is possible to invite artificial vision by using stimulation with electrodes placed on the vision neural system, thereby developing a prosthesis for the blind that might be of value in reading and mobility. In fact, a number of investigators have already exploited this phenomena to produce a functional visual prosthesis, bringing about great advances in this area.

  10. Report of the Federal Advisory Committee on the bird banding laboratory

    Treesearch

    Susan D. Haseltine; Paul R. Schmidt; Bradley D. Bales; David N. Bonter; David F. DeSante; Paul F. Doherty; Charles M. Francis; Paul T. Green; Lesley-Anne Howes; Daniel L. James; J. Jasper Lament; Richard A. Lancia; Ellen I. Paul; C. John Ralph; John G. Rogers; Richard E. Young

    2008-01-01

    In the fall of 2005, the Directors of the U.S. Geological Survey (USGS) and the U.S. Fish and Wildlife Service (FWS) determined that to ensure that the Bird Banding Laboratory (BBL) of the USGS maintains and continues its important support of conservation and management of birds, it should be guided by a clear vision for the future. In order to carry out this task,...

  11. Color vision defects in school going children.

    PubMed

    Shrestha, R K; Joshi, M R; Shakya, S; Ghising, R

    2010-01-01

    Color vision defect can be observed in various diseases of optic nerve and retina and also a significant number of people suffer from the inherited condition of red and green color defect. A cross-sectional descriptive study was designed with purposive sampling of students from various schools of Kathmandu Valley. All children were subjected to color vision evaluation using Ishihara Isochromatic color plates along with other examination to rule out any other causes for color deficiency. A total of 2001 students were examined, 1050 male students and 951 females with mean age of 10.35 (+/- 2.75) and 10.54 (+/- 2.72) respectively. Among the total students examined, 2.1% had some form of color vision defects. Of the male population, 3.9% had color vision defects while none of the female was found with the deficiency. The prevalence of color vision defect in Nepal is significant and comparable with the prevalence quoted in studies from different countries.

  12. 21 CFR 886.5910 - Image intensification vision aid.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Image intensification vision aid. 886.5910 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5910 Image intensification vision aid. (a) Identification. An image intensification vision aid is a battery-powered device intended for...

  13. 21 CFR 886.5910 - Image intensification vision aid.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Image intensification vision aid. 886.5910 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5910 Image intensification vision aid. (a) Identification. An image intensification vision aid is a battery-powered device intended for...

  14. 21 CFR 886.5910 - Image intensification vision aid.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Image intensification vision aid. 886.5910 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5910 Image intensification vision aid. (a) Identification. An image intensification vision aid is a battery-powered device intended for...

  15. 21 CFR 886.5910 - Image intensification vision aid.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Image intensification vision aid. 886.5910 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5910 Image intensification vision aid. (a) Identification. An image intensification vision aid is a battery-powered device intended for...

  16. 21 CFR 886.5910 - Image intensification vision aid.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Image intensification vision aid. 886.5910 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5910 Image intensification vision aid. (a) Identification. An image intensification vision aid is a battery-powered device intended for...

  17. A Practical Solution Using A New Approach To Robot Vision

    NASA Astrophysics Data System (ADS)

    Hudson, David L.

    1984-01-01

    Up to now, robot vision systems have been designed to serve both application development and operational needs in inspection, assembly and material handling. This universal approach to robot vision is too costly for many practical applications. A new industrial vision system separates the function of application program development from on-line operation. A Vision Development System (VDS) is equipped with facilities designed to simplify and accelerate the application program development process. A complimentary but lower cost Target Application System (TASK) runs the application program developed with the VDS. This concept is presented in the context of an actual robot vision application that improves inspection and assembly for a manufacturer of electronic terminal keyboards. Applications developed with a VDS experience lower development cost when compared with conventional vision systems. Since the TASK processor is not burdened with development tools, it can be installed at a lower cost than comparable "universal" vision systems that are intended to be used for both development and on-line operation. The VDS/TASK approach opens more industrial applications to robot vision that previously were not practical because of the high cost of vision systems. Although robot vision is a new technology, it has been applied successfully to a variety of industrial needs in inspection, manufacturing, and material handling. New developments in robot vision technology are creating practical, cost effective solutions for a variety of industrial needs. A year or two ago, researchers and robot manufacturers interested in implementing a robot vision application could take one of two approaches. The first approach was to purchase all the necessary vision components from various sources. That meant buying an image processor from one company, a camera from another and lens and light sources from yet others. The user then had to assemble the pieces, and in most instances he had to write

  18. Advanced helmet vision system (AHVS) integrated night vision helmet mounted display (HMD)

    NASA Astrophysics Data System (ADS)

    Ashcraft, Todd W.; Atac, Robert

    2012-06-01

    Gentex Corporation, under contract to Naval Air Systems Command (AIR 4.0T), designed the Advanced Helmet Vision System to provide aircrew with 24-hour, visor-projected binocular night vision and HMD capability. AHVS integrates numerous key technologies, including high brightness Light Emitting Diode (LED)-based digital light engines, advanced lightweight optical materials and manufacturing processes, and innovations in graphics processing software. This paper reviews the current status of miniaturization and integration with the latest two-part Gentex modular helmet, highlights the lessons learned from previous AHVS phases, and discusses plans for qualification and flight testing.

  19. Color Vision Deficits and Literacy Acquisition.

    ERIC Educational Resources Information Center

    Hurley, Sandra Rollins

    1994-01-01

    Shows that color blindness, whether partial or total, inhibits literacy acquisition. Offers a case study of a third grader with impaired color vision. Presents a review of literature on the topic. Notes that people with color vision deficits are often unaware of the handicap. (RS)

  20. Vision/Visual Perception: An Annotated Bibliography.

    ERIC Educational Resources Information Center

    Weintraub, Sam, Comp.; Cowan, Robert J., Comp.

    An update and modification of "Vision-Visual Discrimination" published in 1973, this annotated bibliography contains entries from the annual summaries of research in reading published by the International Reading Association (IRA) since then. The first large section, "Vision," is divided into two subgroups: (1) "Visually…

  1. Computer vision in the poultry industry

    USDA-ARS?s Scientific Manuscript database

    Computer vision is becoming increasingly important in the poultry industry due to increasing use and speed of automation in processing operations. Growing awareness of food safety concerns has helped add food safety inspection to the list of tasks that automated computer vision can assist. Researc...

  2. Functional Vision Observation. Technical Assistance Paper.

    ERIC Educational Resources Information Center

    Florida State Dept. of Education, Tallahassee. Bureau of Education for Exceptional Students.

    Technical assistance is provided concerning documentation of functional vision loss for Florida students with visual impairments. The functional vision observation should obtain enough information for determination of special service eligibility. The observation is designed to supplement information on the medical eye examination, and is conducted…

  3. Development of a Low Cost 10kW Tubular SOFC Power System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bessette, Norman; Litka, Anthony; Rawson, Jolyon

    The DOE program funded from 2003 through early 2013 has brought the Acumentrics SOFC program from an early stage R&D program to an entry level commercial product offering. The development work started as one of the main core teams under the DOE Solid State Energy Conversion Alliance (SECA) program administered by the National Energy Technology Laboratory (NETL) of the DOE. During the first phase of the program, lasting approximately 3-4 years, a 5kW machine was designed, manufactured and tested against the specification developed by NETL. This unit was also shipped to NETL for independent verification testing which validated all ofmore » the results achieved while in the laboratory at Acumentrics. The Acumentrics unit passed all criteria established from operational stability, efficiency, and cost projections. Passing of the SECA Phase I test allowed the program to move into Phase II of the program. During this phase, the overall objective was to further refine the unit meeting a higher level of performance stability as well as further cost reductions. During the first year of this new phase, the NETL SECA program was refocused towards larger size units and operation on coal gasification due to the severe rise in natural gas prices and refocus on the US supply of indigenous coal. At this point, the program was shifted to the U.S. DOE’s Energy Efficiency and Renewable Energy (EERE) division located in Golden, Colorado. With this shift, the focus remained on smaller power units operational on gaseous fuels for a variety of applications including micro combined heat and power (mCHP). To achieve this goal, further enhancements in power, life expectancy and reductions in cost were necessary. The past 5 years have achieved these goals with machines that can now achieve over 40% electrical efficiency and field units that have now operated for close to a year and a half with minimal maintenance. The following report details not only the first phase while under the SECA

  4. Resource Letter CCV-1: Color and Color Vision.

    ERIC Educational Resources Information Center

    Stuewer, Roger H., Ed.; Pease, Paul L.

    1980-01-01

    Listed are selected resource materials on color vision and the measurement and specification of the stimulus for vision, photometry, and colorimetry. The author's purpose is to equip teachers and students with an understanding of normal and abnormal color vision. References are categorized relative to content level. (Author/DS)

  5. Effectiveness of portable electronic and optical magnifiers for near vision activities in low vision: a randomised crossover trial.

    PubMed

    Taylor, John J; Bambrick, Rachel; Brand, Andrew; Bray, Nathan; Dutton, Michelle; Harper, Robert A; Hoare, Zoe; Ryan, Barbara; Edwards, Rhiannon T; Waterman, Heather; Dickinson, Christine

    2017-07-01

    To compare the performance of near vision activities using additional portable electronic vision enhancement systems (p-EVES), to using optical magnifiers alone, by individuals with visual impairment. A total of 100 experienced optical aid users were recruited from low vision clinics at Manchester Royal Eye Hospital, Manchester, UK, to a prospective two-arm cross-over randomised controlled trial. Reading, performance of near vision activities, and device usage were evaluated at baseline; and at the end of each study arm (Intervention A: existing optical aids plus p-EVES; Intervention B: optical aids only) which was after 2 and 4 months. A total of 82 participants completed the study. Overall, maximum reading speed for high contrast sentences was not statistically significantly different for optical aids and p-EVES, although the critical print size and threshold print size which could be accessed with p-EVES were statistically significantly smaller (p < 0.001 in both cases). The optical aids were used for a larger number of tasks (p < 0.001), and used more frequently (p < 0.001). However p-EVES were preferred for leisure reading by 70% of participants, and allowed longer duration of reading (p < 0.001). During the study arm when they had a p-EVES device, participants were able to carry out more tasks independently (p < 0.001), and reported less difficulty with a range of near vision activities (p < 0.001). The study provides evidence that p-EVES devices can play a useful role in supplementing the range of low vision aids used to reduce activity limitation for near vision tasks. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  6. Operational Assessment of Color Vision

    DTIC Science & Technology

    2016-06-20

    evaluated in this study. 15. SUBJECT TERMS Color vision, aviation, cone contrast test, Colour Assessment & Diagnosis , color Dx, OBVA 16. SECURITY...symbologies are frequently used to aid or direct critical activities such as aircraft landing approaches or railroad right-of-way designations...computer-generated display systems have facilitated the development of computer-based, automated tests of color vision [14,15]. The United Kingdom’s

  7. Telerehabilitation for people with low vision.

    PubMed

    Bittner, Ava K; Wykstra, Stephanie L; Yoshinaga, Patrick D; Li, Tianjing

    2015-08-31

    Low vision affects over 300 million people worldwide and can compromise both activities of daily living and quality of life. Rehabilitative training and vision assistive equipment (VAE) may help, but some visually impaired people have limited resources to attend in-person visits at rehabilitation clinics. These people may be able to overcome barriers to care through remote, Internet-based consultation (i.e., telerehabilitation). To compare the effects of telerehabilitation with face-to-face (e.g., in-office or inpatient) vision rehabilitation services for improving vision-related quality of life and reading speed in people with visual function loss due to any ocular condition. Secondary objectives are to evaluate compliance with scheduled rehabilitation sessions, abandonment rates for visual assistive equipment devices, and patient satisfaction ratings. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (2015 Issue 5), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1980 to June 2015), EMBASE (January 1980 to June 2015), PubMed (1980 to June 2015), ClinicalTrials.gov (www.clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any language restriction or study design filter in the electronic searches; however, we restricted the searches from 1980 onwards because the Internet was not introduced to the public until 1982. We last searched the electronic databases on 15 June 2015. We planned to include randomized controlled trials (RCTs) or controlled clinical trials (CCTs) in which participants were diagnosed with low vision and were undergoing low vision rehabilitation using an Internet, web-based technology compared with an approach based on in-person consultations. Two authors independently screened titles and abstracts, and then full-text articles against

  8. Rebalancing binocular vision in amblyopia.

    PubMed

    Ding, Jian; Levi, Dennis M

    2014-03-01

    Humans with amblyopia have an asymmetry in binocular vision: neural signals from the amblyopic eye are suppressed in the cortex by the fellow eye. The purpose of this study was to develop new models and methods for rebalancing this asymmetric binocular vision by manipulating the contrast and luminance in the two eyes. We measured the perceived phase of a cyclopean sinewave by asking normal and amblyopic observers to indicate the apparent location (phase) of the dark trough in the horizontal cyclopean sine wave relative to a black horizontal reference line, and used the same stimuli to measure perceived contrast by matching the binocular combined contrast to a standard contrast presented to one eye. We varied both the relative contrast and luminance of the two eyes' inputs, in order to rebalance the asymmetric binocular vision. Amblyopic binocular vision becomes more and more asymmetric the higher the stimulus contrast or spatial frequency. Reanalysing our previous data, we found that, at a given spatial frequency, the binocular asymmetry could be described by a log-linear formula with two parameters, one for the maximum asymmetry and one for the rate at which the binocular system becomes asymmetric as the contrast increases. Our new data demonstrates that reducing the dominant eye's mean luminance reduces its suppression of the non-dominant eye, and therefore rebalances the asymmetric binocular vision. While the binocular asymmetry in amblyopic vision can be rebalanced by manipulating the relative contrast or luminance of the two eyes at a given spatial frequency and contrast, it is very difficult or even impossible to rebalance the asymmetry for all visual conditions. Nonetheless, wearing a neutral density filter before the dominant eye (or increasing the mean luminance in the non-dominant eye) may be more beneficial than the traditional method of patching the dominant eye for treating amblyopia. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The

  9. Reproducibility of an objective four-choice canine vision testing technique that assesses vision at differing light intensities.

    PubMed

    Annear, Matthew J; Gornik, Kara R; Venturi, Francesca L; Hauptman, Joe G; Bartoe, Joshua T; Petersen-Jones, Simon M

    2013-09-01

    The increasing importance of canine retinal dystrophy models means accurate vision testing is needed. This study was performed to evaluate a four-choice vision testing technique for any difference in outcome measures with repeated evaluations of the same dogs.   Four 11-month-old RPE65-deficient dogs. Vision was evaluated using a previously described four-choice vision testing device. Four evaluations were performed at 2-week intervals. Vision was assessed at six different white light intensities (bright through dim), and each eye was evaluated separately. The ability to select the one of the four exit tunnels that was open at the far end was assessed ('choice of exit') and recorded as correct or incorrect first tunnel choice. 'Time to exit' the device was also recorded. Both outcomes were analyzed for significance using anova. We hypothesized that performance would improve with repeated testing (more correct choices and more rapid time to exit). 'Choice of exit' did not vary significantly between each evaluation (P = 0.12), in contrast 'time to exit' increased significantly (P = 0.012), and showed greater variability in dim light conditions. We found no evidence to support the hypothesis that either measure of outcome worsened with repeated testing; in fact, the 'time to exit' outcome worsened rather than improved. The 'choice of exit' gave consistent results between trials. These outcome data indicate the importance of including a choice-based assessment of vision in addition to measurement of device transit time. © 2012 American College of Veterinary Ophthalmologists.

  10. 21 CFR 886.1160 - Color vision plate illuminator.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Color vision plate illuminator. 886.1160 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1160 Color vision plate illuminator. (a) Identification. A color vision plate illuminator is an AC-powered device that is a lamp intended...

  11. 21 CFR 886.1160 - Color vision plate illuminator.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Color vision plate illuminator. 886.1160 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1160 Color vision plate illuminator. (a) Identification. A color vision plate illuminator is an AC-powered device that is a lamp intended...

  12. 21 CFR 886.1160 - Color vision plate illuminator.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Color vision plate illuminator. 886.1160 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1160 Color vision plate illuminator. (a) Identification. A color vision plate illuminator is an AC-powered device that is a lamp intended...

  13. 21 CFR 886.1160 - Color vision plate illuminator.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Color vision plate illuminator. 886.1160 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1160 Color vision plate illuminator. (a) Identification. A color vision plate illuminator is an AC-powered device that is a lamp intended...

  14. 21 CFR 886.1160 - Color vision plate illuminator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Color vision plate illuminator. 886.1160 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1160 Color vision plate illuminator. (a) Identification. A color vision plate illuminator is an AC-powered device that is a lamp intended...

  15. Clipping polygon faces through a polyhedron of vision

    NASA Technical Reports Server (NTRS)

    Florence, Judit K. (Inventor); Rohner, Michel A. (Inventor)

    1980-01-01

    A flight simulator combines flight data and polygon face terrain data to provide a CRT display at each window of the simulated aircraft. The data base specifies the relative position of each vertex of each polygon face therein. Only those terrain faces currently appearing within the pyramid of vision defined by the pilots eye and the edges of the pilots window need be displayed at any given time. As the orientation of the pyramid of vision changes in response to flight data, the displayed faces are correspondingly displaced, eventually moving out of the pyramid of vision. Faces which are currently not visible (outside the pyramid of vision) are clipped from the data flow. In addition, faces which are only partially outside of pyramid of vision are reconstructed to eliminate the outside portion. Window coordinates are generated defining the distance between each vertex and each of the boundary planes forming the pyramid of vision. The sign bit of each window coordinate indicates whether the vertex is on the pyramid of vision side of the associated boundary panel (positive), or on the other side thereof (negative). The set of sign bits accompanying each vertex constitute the outcode of that vertex. The outcodes (O.C.) are systematically processed and examined to determine which faces are completely inside the pyramid of vision (Case A--all signs positive), which faces are completely outside (Case C--All signs negative) and which faces must be reconstructed (Case B--both positive and negative signs).

  16. Witnessing Evolution First Hand: A K-12 Laboratory Exercise in Genetics & Evolution Using "Drosophila"

    ERIC Educational Resources Information Center

    Heil, Caiti S. S.; Manzano-Winkler, Brenda; Hunter, Mika J.; Noor, Juliet K. F.; Noor, Mohamed A. F.

    2013-01-01

    We present a laboratory exercise that leverages student interest in genetics to observe and understand evolution by natural selection. Students begin with white-eyed fruit fly populations, to which they introduce a single advantageous variant (one male with red eyes). The superior health and vision associated with having the red-eye-color allele…

  17. Riemann tensor of motion vision revisited.

    PubMed

    Brill, M

    2001-07-02

    This note shows that the Riemann-space interpretation of motion vision developed by Barth and Watson is neither necessary for their results, nor sufficient to handle an intrinsic coordinate problem. Recasting the Barth-Watson framework as a classical velocity-solver (as in computer vision) solves these problems.

  18. A computer vision for animal ecology.

    PubMed

    Weinstein, Ben G

    2018-05-01

    A central goal of animal ecology is to observe species in the natural world. The cost and challenge of data collection often limit the breadth and scope of ecological study. Ecologists often use image capture to bolster data collection in time and space. However, the ability to process these images remains a bottleneck. Computer vision can greatly increase the efficiency, repeatability and accuracy of image review. Computer vision uses image features, such as colour, shape and texture to infer image content. I provide a brief primer on ecological computer vision to outline its goals, tools and applications to animal ecology. I reviewed 187 existing applications of computer vision and divided articles into ecological description, counting and identity tasks. I discuss recommendations for enhancing the collaboration between ecologists and computer scientists and highlight areas for future growth of automated image analysis. © 2017 The Author. Journal of Animal Ecology © 2017 British Ecological Society.

  19. Nonanalytic Laboratory Automation: A Quarter Century of Progress.

    PubMed

    Hawker, Charles D

    2017-06-01

    Clinical laboratory automation has blossomed since the 1989 AACC meeting, at which Dr. Masahide Sasaki first showed a western audience what his laboratory had implemented. Many diagnostics and other vendors are now offering a variety of automated options for laboratories of all sizes. Replacing manual processing and handling procedures with automation was embraced by the laboratory community because of the obvious benefits of labor savings and improvement in turnaround time and quality. Automation was also embraced by the diagnostics vendors who saw automation as a means of incorporating the analyzers purchased by their customers into larger systems in which the benefits of automation were integrated to the analyzers.This report reviews the options that are available to laboratory customers. These options include so called task-targeted automation-modules that range from single function devices that automate single tasks (e.g., decapping or aliquoting) to multifunction workstations that incorporate several of the functions of a laboratory sample processing department. The options also include total laboratory automation systems that use conveyors to link sample processing functions to analyzers and often include postanalytical features such as refrigerated storage and sample retrieval.Most importantly, this report reviews a recommended process for evaluating the need for new automation and for identifying the specific requirements of a laboratory and developing solutions that can meet those requirements. The report also discusses some of the practical considerations facing a laboratory in a new implementation and reviews the concept of machine vision to replace human inspections. © 2017 American Association for Clinical Chemistry.

  20. New color vision tests to evaluate faulty color recognition.

    PubMed

    Nakamura, Kaoru; Okajima, Osamu; Nishio, Yoshiteru; Kitahara, Kenji

    2002-01-01

    To develop and assess new color vision tests to be used in evaluating faulty color recognition. We developed new color vision tests to evaluate faulty color recognition. The two types of color vision tests, designed to assess faulty color recognition in color vision deficiencies, are based on principles that are different from those of the conventional color vision tests. In the first test plate, the subject is asked to choose either a red, green, or gray line from among 10 lines that are randomly colored red, green, gray, yellow, or blue. The score is the difference between the number of correct answers and the number of incorrect answers. In the second test plate, the subject is asked to identify a total of 10 red azalea blossoms, which are dispersed among numerous green leaves. Seventy-five persons with congenital color deficiencies and 20 subjects with normal color vision were examined using these new test plates. The scores differed significantly between dichromats and anomalous trichromats, and between anomalous trichromats and subjects with normal color vision. The new tests are easy to use, sensitive, and have good reproducibility for use in discriminating subjects with color vision anomalies. These tests reveal the faulty color recognition that occurs unconsciously in persons with color deficiencies, and are useful in judging the quantification of color vision required in their daily life and occupations.

  1. Aircraft cockpit vision: Math model

    NASA Technical Reports Server (NTRS)

    Bashir, J.; Singh, R. P.

    1975-01-01

    A mathematical model was developed to describe the field of vision of a pilot seated in an aircraft. Given the position and orientation of the aircraft, along with the geometrical configuration of its windows, and the location of an object, the model determines whether the object would be within the pilot's external vision envelope provided by the aircraft's windows. The computer program using this model was implemented and is described.

  2. Machine Vision For Industrial Control:The Unsung Opportunity

    NASA Astrophysics Data System (ADS)

    Falkman, Gerald A.; Murray, Lawrence A.; Cooper, James E.

    1984-05-01

    Vision modules have primarily been developed to relieve those pressures newly brought into existence by Inspection (QUALITY) and Robotic (PRODUCTIVITY) mandates. Industrial Control pressure stems on the other hand from the older first industrial revolution mandate of throughput. Satisfying such pressure calls for speed in both imaging and decision making. Vision companies have, however, put speed on a backburner or ignore it entirely because most modules are computer/software based which limits their speed potential. Increasingly, the keynote being struck at machine vision seminars is that "Visual and Computational Speed Must Be Increased and Dramatically!" There are modular hardwired-logic systems that are fast but, all too often, they are not very bright. Such units: Measure the fill factor of bottles as they spin by, Read labels on cans, Count stacked plastic cups or Monitor the width of parts streaming past the camera. Many are only a bit more complex than a photodetector. Once in place, most of these units are incapable of simple upgrading to a new task and are Vision's analog to the robot industry's pick and place (RIA TYPE E) robot. Vision thus finds itself amidst the same quandries that once beset the Robot Industry of America when it tried to define a robot, excluded dumb ones, and was left with only slow machines whose unit volume potential is shatteringly low. This paper develops an approach to meeting the need of a vision system that cuts a swath into the terra incognita of intelligent, high-speed vision processing. Main attention is directed to vision for industrial control. Some presently untapped vision application areas that will be serviced include: Electronics, Food, Sports, Pharmaceuticals, Machine Tools and Arc Welding.

  3. Vision-based aircraft guidance

    NASA Technical Reports Server (NTRS)

    Menon, P. K.

    1993-01-01

    Early research on the development of machine vision algorithms to serve as pilot aids in aircraft flight operations is discussed. The research is useful for synthesizing new cockpit instrumentation that can enhance flight safety and efficiency. With the present work as the basis, future research will produce low-cost instrument by integrating a conventional TV camera together with off-the=shelf digitizing hardware for flight test verification. Initial focus of the research will be on developing pilot aids for clear-night operations. Latter part of the research will examine synthetic vision issues for poor visibility flight operations. Both research efforts will contribute towards the high-speed civil transport aircraft program. It is anticipated that the research reported here will also produce pilot aids for conducting helicopter flight operations during emergency search and rescue. The primary emphasis of the present research effort is on near-term, flight demonstrable technologies. This report discusses pilot aids for night landing and takeoff and synthetic vision as an aid to low visibility landing.

  4. Agrarian Visions.

    ERIC Educational Resources Information Center

    Theobald, Paul

    A new feature in "Country Teacher,""Agrarian Visions" reminds rural teachers that they can do something about rural decline. Like to populism of the 1890s, the "new populism" advocates rural living. Current attempts to address rural decline are contrary to agrarianism because: (1) telecommunications experts seek to…

  5. Efficacy of vision restoration therapy after optic neuritis (VISION study): study protocol for a randomized controlled trial.

    PubMed

    Schinzel, Johann; Schwarzlose, Lina; Dietze, Holger; Bartusch, Karolina; Weiss, Susanne; Ohlraun, Stephanie; Paul, Friedemann; Dörr, Jan

    2012-06-28

    Optic neuritis is a frequent manifestation of multiple sclerosis. Visual deficits range from a minor impairment of visual functions through to complete loss of vision. Although many patients recover almost completely, roughly 35% of patients remain visually impaired for years, and therapeutic options for those patients hardly exist. Vision restoration therapy is a software-based visual training program that has been shown to improve visual deficits after pre- and postchiasmatic injury. The aim of this pilot study is to evaluate whether residual visual deficits after past or recent optic neuritis can be reduced by means of vision restoration therapy. A randomized, controlled, patient- and observer-blinded clinical pilot study (VISION study) was designed to evaluate the efficacy of vision restoration therapy in optic neuritis patients. Eighty patients with a residual visual deficit after optic neuritis (visual acuity ≤0.7 and/or scotoma) will be stratified according to the time of optic neuritis onset (manifestation more than 12 months ago (40 patients, fixed deficit) versus manifestation 2 to 6 months ago (40 patients, recent optic neuritis)), and randomized into vision restoration therapy arm or saccadic training arm (control intervention). Patients will be instructed to complete a computer-based visual training for approximately 30 minutes each day for a period of 6 months. Patients and evaluators remain blinded to the treatment allocation throughout the study. All endpoints will be analyzed and P-values < 0.05 will be considered statistically significant. The primary outcome parameter will be the expansion of the visual field after 3 and 6 months of treatment as determined by static visual field perimetry and high resolution perimetry. Secondary outcome variables will include visual acuity at both low and high contrast, glare contrast sensitivity, visually evoked potentials, optical coherence tomography and other functional tests of the visual system, alertness

  6. Causes of vision impairment and assessment of need for low vision services for students of blind schools in Nepal.

    PubMed

    Kansakar, I; Thapa, H B; Salma, K C; Ganguly, S; Kandel, R P; Rajasekaran, S

    The present study is first of its kind to evaluate causes of visual impairment of blind students in Nepal and assess their need for low vision rehabilitation services. To evaluate causes of vision impairment of students enrolled in blind schools in Nepal and assess the need for low vision rehabilitation services in these students. A survey was conducted in 12 blind schools in Nepal, which were registered with Nepal Association for Welfare of Blindness (NAWB).It was conducted by a team of an ophthalmologist and an optometrist, by using standard eye examination protocols of the World Health Organization Prevention of Blindness Program (WHO/PBL). Of the 345 students enrolled in 12 schools, 285 students were examined (response rate of 82.61%). The students were in the 5 - 29 years age group. Nearly three-fourth of the children had become blind within one year of age and 52.3% visually impaired at birth and 20.7% developed vision impairment within one year of age. After refraction, 26 students (9.12%) had mild visual impairment, 21 students (7.37%) had severe visual impairment and 238 students (83.51%) were blind. The main cause of vision impairment was found to be corneal 35.79% and retina diseases, mainly dystrophy, 20.35% followed by problems with the whole globe, lens and optic nerve, accounting for 13.33%, 12.63% and 12.98% respectively. The major etiological factors were those of childhood such as Vitamin A deficiency, measles and similar causes (42.11%) followed by hereditary causes (25.26%). Of the total students examined, 48.07% were visually impaired due to preventable causes and 16.14% treatable aggregating to 64.21% of avoidable blindness. Fifty seven (28.22%) students could read smaller than 2 M print size after low vision assessment for near and 33(15.78%) students benefited with telescopic trial for distance low vision. In Nepal, renewed focus on providing best possible quality of life for visually impaired children by proper low vision assessment and eye

  7. From Academic Vision to Physical Manifestation

    ERIC Educational Resources Information Center

    Walleri, R. Dan; Becker, William E.

    2004-01-01

    This community college-based case study describes and analyzes how a new mission and vision adopted by the college trustees was translated into a facility master plan. The vision is designed to serve the needs of the community and facilitate economic development, especially in the areas of health occupations, biotechnology and…

  8. Family Functioning and Low Vision: A Systematic Review

    ERIC Educational Resources Information Center

    Bambara, Jennifer K.; Wadley, Virginia; Owsley, Cynthia; Martin, Roy C.; Porter, Chebon; Dreer, Laura E.

    2009-01-01

    This review highlights the literature on the function and adjustment process of family members of persons with adult-onset vision loss. The majority of the literature has focused on the unique role that the family plays in providing both instrumental and emotional support to adults with low vision. In contrast, the impact of low vision on the…

  9. Robotic vision. [process control applications

    NASA Technical Reports Server (NTRS)

    Williams, D. S.; Wilf, J. M.; Cunningham, R. T.; Eskenazi, R.

    1979-01-01

    Robotic vision, involving the use of a vision system to control a process, is discussed. Design and selection of active sensors employing radiation of radio waves, sound waves, and laser light, respectively, to light up unobservable features in the scene are considered, as are design and selection of passive sensors, which rely on external sources of illumination. The segmentation technique by which an image is separated into different collections of contiguous picture elements having such common characteristics as color, brightness, or texture is examined, with emphasis on the edge detection technique. The IMFEX (image feature extractor) system performing edge detection and thresholding at 30 frames/sec television frame rates is described. The template matching and discrimination approach to recognize objects are noted. Applications of robotic vision in industry for tasks too monotonous or too dangerous for the workers are mentioned.

  10. Coevolution of coloration and colour vision?

    PubMed

    Lind, Olle; Henze, Miriam J; Kelber, Almut; Osorio, Daniel

    2017-07-05

    The evolutionary relationship between signals and animal senses has broad significance, with potential consequences for speciation, and for the efficacy and honesty of biological communication. Here we outline current understanding of the diversity of colour vision in two contrasting groups: the phylogenetically conservative birds, and the more variable butterflies. Evidence for coevolution of colour signals and vision exists in both groups, but is limited to observations of phenotypic differences between visual systems, which might be correlated with coloration. Here, to illustrate how one might interpret the evolutionary significance of such differences, we used colour vision modelling based on an avian eye to evaluate the effects of variation in three key characters: photoreceptor spectral sensitivity, oil droplet pigmentation and the proportions of different photoreceptor types. The models predict that physiologically realistic changes in any one character will have little effect, but complementary shifts in all three can substantially affect discriminability of three types of natural spectra. These observations about the adaptive landscape of colour vision may help to explain the general conservatism of photoreceptor spectral sensitivities in birds. This approach can be extended to other types of eye and spectra to inform future work on coevolution of coloration and colour vision.This article is part of the themed issue 'Animal coloration: production, perception, function and application'. © 2017 The Author(s).

  11. Molecular basis of abnormal red-green color vision: a family with three types of color vision defects.

    PubMed Central

    Drummond-Borg, M; Deeb, S; Motulsky, A G

    1988-01-01

    The molecular nature of three different types of X-linked color-vision defects, protanomaly, deuteranomaly, and protanopia, in a large 3-generation family was determined. In the protanomalous and protanopic males the normal red pigment gene was replaced by a 5' red-3' green fusion gene. The protanomalous male had more red pigment DNA in his fusion gene than did the more severely affected protanopic individual. The deuteranomalous individual had four green pigment genes and one 5' green-3' red fusion gene. These results extend those of Nathans et al., who proposed that most red-green color-vision defects arise as a result of unequal crossing-over between the red and green pigment genes. The various data suggest that differences in severity of color-vision defects associated with fusion genes are caused by differences in crossover sites between the red and green pigment genes. Currently used molecular methodology is not sufficiently sensitive to define these fusion points accurately, and the specific color-vision defect within the deutan or protan class cannot be predicted. The DNA patterns for color-vision genes of female heterozygotes have not previously been described. Patterns of heterozygotes may not be distinguishable from those of normals. However, a definite assignment of the various color pigment gene arrays could be carried out by family study. Two compound heterozygotes for color-vision defects who tested as normal by anomaloscopy were found to carry abnormal fusion genes. In addition, a normal red pigment gene was present on one chromosome and at least one normal green pigment gene was present on the other.(ABSTRACT TRUNCATED AT 250 WORDS) Images Figure 3 PMID:2847528

  12. Night vision: changing the way we drive

    NASA Astrophysics Data System (ADS)

    Klapper, Stuart H.; Kyle, Robert J. S.; Nicklin, Robert L.; Kormos, Alexander L.

    2001-03-01

    A revolutionary new Night Vision System has been designed to help drivers see well beyond their headlights. From luxury automobiles to heavy trucks, Night Vision is helping drivers see better, see further, and react sooner. This paper describes how Night Vision Systems are being used in transportation and their viability for the future. It describes recent improvements to the system currently in the second year of production. It also addresses consumer education and awareness, cost reduction, product reliability, market expansion and future improvements.

  13. Vision servo of industrial robot: A review

    NASA Astrophysics Data System (ADS)

    Zhang, Yujin

    2018-04-01

    Robot technology has been implemented to various areas of production and life. With the continuous development of robot applications, requirements of the robot are also getting higher and higher. In order to get better perception of the robots, vision sensors have been widely used in industrial robots. In this paper, application directions of industrial robots are reviewed. The development, classification and application of robot vision servo technology are discussed, and the development prospect of industrial robot vision servo technology is proposed.

  14. Aviator's night vision system (ANVIS) in Operation Enduring Freedom (OEF): user acceptability survey

    NASA Astrophysics Data System (ADS)

    Hiatt, Keith L.; Trollman, Christopher J.; Rash, Clarence E.

    2010-04-01

    In 1973, the U.S. Army adopted night vision devices for use in the aviation environment. These devices are based on the principle of image intensification (I2) and have become the mainstay for the aviator's capability to operate during periods of low illumination, i.e., at night. In the nearly four decades that have followed, a number of engineering advancements have significantly improved the performance of these devices. The current version, using 3rd generation I2 technology is known as the Aviator's Night Vision Imaging System (ANVIS). While considerable experience with performance has been gained during training and peacetime operations, no previous studies have looked at user acceptability and performance issues in a combat environment. This study was designed to compare Army Aircrew experiences in a combat environment to currently available information in the published literature (all peacetime laboratory and field training studies) and to determine if the latter is valid. The purpose of this study was to identify and assess aircrew satisfaction with the ANVIS and any visual performance issues or problems relating to its use in Operation Enduring Freedom (OEF). The study consisted of an anonymous survey (based on previous validated surveys used in the laboratory and training environments) of 86 Aircrew members (64% Rated and 36% Non-rated) of an Aviation Task Force approximately 6 months into their OEF deployment. This group represents an aggregate of >94,000 flight hours of which ~22,000 are ANVIS and ~16,000 during this deployment. Overall user acceptability of ANVIS in a combat environment will be discussed.

  15. [Acquired disorders of color vision].

    PubMed

    Lascu, Lidia; Balaş, Mihaela

    2002-01-01

    This article is a general view of acquired disorders of color vision. The revision of the best known methods and of the etiopathogenic classification is not very important in ophthalmology but on the other hand, the detection of the blue defect advertise and associated ocular pathology. There is a major interest in serious diseases as multiple sclerosis, AIDS, diabetes melitus, when the first ocular sign can be a defect in the color vision.

  16. Adaptive optics for peripheral vision

    NASA Astrophysics Data System (ADS)

    Rosén, R.; Lundström, L.; Unsbo, P.

    2012-07-01

    Understanding peripheral optical errors and their impact on vision is important for various applications, e.g. research on myopia development and optical correction of patients with central visual field loss. In this study, we investigated whether correction of higher order aberrations with adaptive optics (AO) improve resolution beyond what is achieved with best peripheral refractive correction. A laboratory AO system was constructed for correcting peripheral aberrations. The peripheral low contrast grating resolution acuity in the 20° nasal visual field of the right eye was evaluated for 12 subjects using three types of correction: refractive correction of sphere and cylinder, static closed loop AO correction and continuous closed loop AO correction. Running AO in continuous closed loop improved acuity compared to refractive correction for most subjects (maximum benefit 0.15 logMAR). The visual improvement from aberration correction was highly correlated with the subject's initial amount of higher order aberrations (p = 0.001, R 2 = 0.72). There was, however, no acuity improvement from static AO correction. In conclusion, correction of peripheral higher order aberrations can improve low contrast resolution, provided refractive errors are corrected and the system runs in continuous closed loop.

  17. Research the mobile phone operation interfaces for vision-impairment.

    PubMed

    Yao, Yen-Ting; Leung, Cherng-Yee

    2012-01-01

    Due to the vision-impaired users commonly having difficulty with mobile-phone function operations and adaption any manufacturer's user interface design, the goals for this research are established for evaluating how to improve for them the function operation convenience and user interfaces of either mobile phones or electronic appliances in the market currently. After applying collecting back 30 effective questionnaires from 30 vision-impairment, the comments have been concluded from this research include: (1) All mobile phone manufactures commonly ignorant of the vision-impairment difficulty with operating mobile phone user interfaces; (2) The vision-impairment preferential with audio alert signals; (3) The vision-impairment incapable of mobile-phone procurement independently unless with assistance from others; (4) Preferential with adding touch-usage interface design by the vision-impairment; in contrast with the least requirement for such functions as braille, enlarging keystroke size and diversifying-function control panel. With exploring the vision-impairment's necessary improvements and obstacles for mobile phone interface operation, this research is established with goals for offering reference possibly applied in electronic appliance design and . Hopefully, the analysis results of this research could be used as data references for designing electronic and high-tech products and promoting more usage convenience for those vision-impaired.

  18. Telerehabilitation for people with low vision

    PubMed Central

    Bittner, Ava K; Wykstra, Stephanie L; Yoshinaga, Patrick D; Li, Tianjing

    2016-01-01

    Background Low vision affects over 300 million people worldwide and can compromise both activities of daily living and quality of life. Rehabilitative training and vision assistive equipment (VAE) may help, but some visually impaired people have limited resources to attend in-person visits at rehabilitation clinics. These people may be able to overcome barriers to care through remote, Internet-based consultation (i.e., telerehabilitation). Objectives To compare the effects of telerehabilitation with face-to-face (e.g., in-office or inpatient) vision rehabilitation services for improving vision-related quality of life and reading speed in people with visual function loss due to any ocular condition. Secondary objectives are to evaluate compliance with scheduled rehabilitation sessions, abandonment rates for visual assistive equipment devices, and patient satisfaction ratings. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (2015 Issue 5), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1980 to June 2015), EMBASE (January 1980 to June 2015), PubMed (1980 to June 2015), ClinicalTrials.gov (www.clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any language restriction or study design filter in the electronic searches; however, we restricted the searches from 1980 onwards because the Internet was not introduced to the public until 1982. We last searched the electronic databases on 15 June 2015. Selection criteria We planned to include randomized controlled trials (RCTs) or controlled clinical trials (CCTs) in which participants were diagnosed with low vision and were undergoing low vision rehabilitation using an Internet, web-based technology compared with an approach based on in-person consultations. Data collection and analysis Two

  19. A Low Vision Reading Comprehension Test.

    ERIC Educational Resources Information Center

    Watson, G. R.; And Others

    1996-01-01

    Fifty adults (ages 28-86) with macular degeneration were given the Low Vision Reading Comprehension Assessment (LVRCA) to test its reliability and validity in evaluating the reading comprehension of those with vision impairments. The LVRCA was found to take only nine minutes to administer and was a valid and reliable tool. (CR)

  20. Predicting Visual Disability in Glaucoma With Combinations of Vision Measures.

    PubMed

    Lin, Stephanie; Mihailovic, Aleksandra; West, Sheila K; Johnson, Chris A; Friedman, David S; Kong, Xiangrong; Ramulu, Pradeep Y

    2018-04-01

    We characterized vision in glaucoma using seven visual measures, with the goals of determining the dimensionality of vision, and how many and which visual measures best model activity limitation. We analyzed cross-sectional data from 150 older adults with glaucoma, collecting seven visual measures: integrated visual field (VF) sensitivity, visual acuity, contrast sensitivity (CS), area under the log CS function, color vision, stereoacuity, and visual acuity with noise. Principal component analysis was used to examine the dimensionality of vision. Multivariable regression models using one, two, or three vision tests (and nonvisual predictors) were compared to determine which was best associated with Rasch-analyzed Glaucoma Quality of Life-15 (GQL-15) person measure scores. The participants had a mean age of 70.2 and IVF sensitivity of 26.6 dB, suggesting mild-to-moderate glaucoma. All seven vision measures loaded similarly onto the first principal component (eigenvectors, 0.220-0.442), which explained 56.9% of the variance in vision scores. In models for GQL scores, the maximum adjusted- R 2 values obtained were 0.263, 0.296, and 0.301 when using one, two, and three vision tests in the models, respectively, though several models in each category had similar adjusted- R 2 values. All three of the best-performing models contained CS. Vision in glaucoma is a multidimensional construct that can be described by several variably-correlated vision measures. Measuring more than two vision tests does not substantially improve models for activity limitation. A sufficient description of disability in glaucoma can be obtained using one to two vision tests, especially VF and CS.

  1. Mission statements and vision documents in medical practices.

    PubMed

    Drury, Ivo; Slomski, Carol

    2006-01-01

    Thoughtful, carefully constructed mission statements and vision documents serve both to signal the purpose of a medical practice to the public and other professional colleagues, and to keep the practice's providers focused on its key purposes. Practice culture is the primary driver ofmission and vision. We clarify the differences between mission statements and vision documents, and offer guidelines to aid in constructing them.

  2. 76 FR 12216 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-04

    ...; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION... exemptions from the vision requirement in the Federal Motor Carrier Safety Regulations for 11 individuals. FMCSA has statutory authority to exempt individuals from the vision requirement if the exemptions...

  3. 77 FR 46153 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-02

    ...; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION... exemptions from the vision requirement in the Federal Motor Carrier Safety Regulations for 48 individuals. FMCSA has statutory authority to exempt individuals from the vision requirement if the exemptions...

  4. 77 FR 64582 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-22

    ...] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety Administration... decision to renew the exemptions from the vision requirement in the Federal Motor Carrier Safety Regulations for 17 individuals. FMCSA has statutory authority to exempt individuals from the vision...

  5. 78 FR 16035 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-13

    ...; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION... exemptions from the vision requirement in the Federal Motor Carrier Safety Regulations for 5 individuals. FMCSA has statutory authority to exempt individuals from the vision requirement if the exemptions...

  6. 76 FR 70215 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-10

    ...; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION... exemptions from the vision requirement in the Federal Motor Carrier Safety Regulations for 20 individuals. FMCSA has statutory authority to exempt individuals from the vision requirement if the exemptions...

  7. 76 FR 44652 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-26

    ...] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety Administration... decision to renew the exemptions from the vision requirement in the Federal Motor Carrier Safety Regulations for 26 individuals. FMCSA has statutory authority to exempt individuals from the vision...

  8. 77 FR 3554 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-24

    ...; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION... exemptions from the vision requirement in the Federal Motor Carrier Safety Regulations for 6 individuals. FMCSA has statutory authority to exempt individuals from the vision requirement if the exemptions...

  9. 75 FR 1451 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-11

    ...; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION... exemptions from the vision requirement in the Federal Motor Carrier Safety Regulations for 13 individuals. FMCSA has statutory authority to exempt individuals from the vision requirement if the exemptions...

  10. 77 FR 36338 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-18

    ...; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION... exemptions from the vision requirement in the Federal Motor Carrier Safety Regulations for 25 individuals. FMCSA has statutory authority to exempt individuals from the vision requirement if the exemptions...

  11. 76 FR 32017 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-02

    ...; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION... exemptions from the vision requirement in the Federal Motor Carrier Safety Regulations for 18 individuals. FMCSA has statutory authority to exempt individuals from the vision requirement if the exemptions...

  12. 78 FR 64280 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-28

    ...; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION... exemptions from the vision requirement in the Federal Motor Carrier Safety Regulations for 17 individuals. FMCSA has statutory authority to exempt individuals from the vision requirement if the exemptions...

  13. Self calibration of the stereo vision system of the Chang'e-3 lunar rover based on the bundle block adjustment

    NASA Astrophysics Data System (ADS)

    Zhang, Shuo; Liu, Shaochuang; Ma, Youqing; Qi, Chen; Ma, Hao; Yang, Huan

    2017-06-01

    The Chang'e-3 was the first lunar soft landing probe of China. It was composed of the lander and the lunar rover. The Chang'e-3 successful landed in the northwest of the Mare Imbrium in December 14, 2013. The lunar rover completed the movement, imaging and geological survey after landing. The lunar rover equipped with a stereo vision system which was made up of the Navcam system, the mast mechanism and the inertial measurement unit (IMU). The Navcam system composed of two cameras with the fixed focal length. The mast mechanism was a robot with three revolute joints. The stereo vision system was used to determine the position of the lunar rover, generate the digital elevation models (DEM) of the surrounding region and plan the moving paths of the lunar rover. The stereo vision system must be calibrated before use. The control field could be built to calibrate the stereo vision system in the laboratory on the earth. However, the parameters of the stereo vision system would change after the launch, the orbital changes, the braking and the landing. Therefore, the stereo vision system should be self calibrated on the moon. An integrated self calibration method based on the bundle block adjustment is proposed in this paper. The bundle block adjustment uses each bundle of ray as the basic adjustment unit and the adjustment is implemented in the whole photogrammetric region. The stereo vision system can be self calibrated with the proposed method under the unknown lunar environment and all parameters can be estimated simultaneously. The experiment was conducted in the ground lunar simulation field. The proposed method was compared with other methods such as the CAHVOR method, the vanishing point method, the Denavit-Hartenberg method, the factorization method and the weighted least-squares method. The analyzed result proved that the accuracy of the proposed method was superior to those of other methods. Finally, the proposed method was practical used to self calibrate the

  14. A Clear Vision for Equity and Opportunity.

    ERIC Educational Resources Information Center

    Gould, Marge Christensen; Gould, Herman

    2003-01-01

    Describes undetected and uncorrected vision problems for children in poverty associated with juvenile delinquency and poor academic performance. Discusses success of a project offering vision screening and free glasses for at-risk students in Tucson, Arizona. (PKP)

  15. Parallel inputs to memory in bee colour vision.

    PubMed

    Horridge, Adrian

    2016-03-01

    In the 19(th) century, it was found that attraction of bees to light was controlled by light intensity irrespective of colour, and a few critical entomologists inferred that vision of bees foraging on flowers was unlike human colour vision. Therefore, quite justly, Professor Carl von Hess concluded in his book on the Comparative Physiology of Vision (1912) that bees do not distinguish colours in the way that humans enjoy. Immediately, Karl von Frisch, an assistant in the Zoology Department of the same University of Münich, set to work to show that indeed bees have colour vision like humans, thereby initiating a new research tradition, and setting off a decade of controversy that ended only at the death of Hess in 1923. Until 1939, several researchers continued the tradition of trying to untangle the mechanism of bee vision by repeatedly testing trained bees, but made little progress, partly because von Frisch and his legacy dominated the scene. The theory of trichromatic colour vision further developed after three types of receptors sensitive to green, blue, and ultraviolet (UV), were demonstrated in 1964 in the bee. Then, until the end of the century, all data was interpreted in terms of trichromatic colour space. Anomalies were nothing new, but eventually after 1996 they led to the discovery that bees have a previously unknown type of colour vision based on a monochromatic measure and distribution of blue and measures of modulation in green and blue receptor pathways. Meanwhile, in the 20(th) century, search for a suitable rationalization, and explorations of sterile culs-de-sac had filled the literature of bee colour vision, but were based on the wrong theory.

  16. 78 FR 74223 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-10

    ...-0298] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces its decision to renew the exemptions from the vision requirement in the Federal Motor Carrier Safety Regulations for 3 individuals. FMCSA has statutory authority to exempt individuals from the vision...

  17. 76 FR 70213 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-10

    ...-0298] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from 7 individuals for exemption from the vision requirement in the... vision requirement. DATES: Comments must be received on or before December 12, 2011. ADDRESSES: You may...

  18. 75 FR 54958 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-09

    ...-0201] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from 15 individuals for exemption from the vision requirement in the... vision standard. DATES: Comments must be received on or before October 12, 2010. ADDRESSES: You may...

  19. 76 FR 53708 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-29

    ... Applications; Vision AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION: Notice of... from the vision requirement in the Federal Motor Carrier Safety Regulations for 28 individuals. FMCSA has statutory authority to exempt individuals from the vision requirement if the exemptions granted...

  20. 78 FR 51268 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-20

    ...-24015; FMCSA-2011-0024; FMCSA-2011-0102] Qualification of Drivers; Exemption Applications; Vision AGENCY... for comments. SUMMARY: FMCSA announces its decision to renew the exemptions from the vision... to exempt individuals from the vision requirement if the exemptions granted will not compromise...

  1. 78 FR 78475 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-26

    ...-2005-22727] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier.... SUMMARY: FMCSA announces its decision to renew the exemptions from the vision requirement in the Federal... from the vision requirement if the exemptions granted will not compromise safety. The Agency has...

  2. 76 FR 70210 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-10

    ...] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety Administration... decision to renew the exemptions from the vision requirement in the Federal Motor Carrier Safety... vision requirement if the exemptions granted will not compromise safety. The Agency has concluded that...

  3. 78 FR 11731 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-19

    ... Applications; Vision AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION: Notice of... from the vision requirement in the Federal Motor Carrier Safety Regulations for 12 individuals. FMCSA has statutory authority to exempt individuals from the vision requirement if the exemptions granted...

  4. 77 FR 64583 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-22

    ... Applications; Vision AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION: Notice of... from the vision requirement in the Federal Motor Carrier Safety Regulations for 16 individuals. FMCSA has statutory authority to exempt individuals from the vision requirement if the exemptions granted...

  5. 78 FR 1921 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-09

    ...-0039] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from 13 individuals for exemption from the vision requirement in the... vision requirement. DATES: Comments must be received on or before February 8, 2013. ADDRESSES: You may...

  6. 78 FR 18667 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-27

    ...-2011-0010] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier.... SUMMARY: FMCSA announces its decision to renew the exemptions from the vision requirement in the Federal... from the vision requirement if the exemptions granted will not compromise safety. The Agency has...

  7. 75 FR 1453 - Qualification of Drivers; Exemption Renewals; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-11

    ...; Exemption Renewals; Vision AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION: Notice... the vision requirement in the Federal Motor Carrier Safety Regulations for 23 individuals. FMCSA has statutory authority to exempt individuals from the vision requirement if the exemptions granted will not...

  8. 78 FR 76394 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-17

    ...] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety Administration... individuals who requested an exemption from the Federal vision standard applicable to interstate truck and bus... vision requirement if the exemptions granted will not compromise safety. The Agency has concluded that...

  9. 78 FR 68137 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-13

    ...-2006-26653; FMCSA-2007-27897; FMCSA-2011-0141] Qualification of Drivers; Exemption Applications; Vision...; request for comments. SUMMARY: FMCSA announces its decision to renew the exemptions from the vision... to exempt individuals from the vision requirement if the exemptions granted will not compromise...

  10. 76 FR 9856 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-22

    ...-0010] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from 23 individuals for exemption from the vision requirement in the... meeting the Federal vision standard. DATES: Comments must be received on or before March 24, 2011...

  11. 77 FR 23797 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-20

    ... Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT... renew the exemptions from the vision requirement in the Federal Motor Carrier Safety Regulations for 29 individuals. FMCSA has statutory authority to exempt individuals from the vision requirement if the exemptions...

  12. 76 FR 17483 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-29

    ... Applications; Vision AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION: Notice of... from the vision requirement in the Federal Motor Carrier Safety Regulations for 21 individuals. FMCSA has statutory authority to exempt individuals from the vision requirement if the exemptions granted...

  13. 78 FR 22596 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-16

    ...; Vision AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION: Notice of renewal of... vision requirement in the Federal Motor Carrier Safety Regulations for 38 individuals. FMCSA has statutory authority to exempt individuals from the vision requirement if the exemptions granted will not...

  14. 77 FR 7657 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-13

    ...-0324] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from 11 individuals for exemption from the vision requirement in the... vision requirement. DATES: Comments must be received on or before March 14, 2012. ADDRESSES: You may...

  15. 75 FR 1453 - Qualification of Drivers; Exemption Renewals; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-11

    ... Renewals; Vision AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION: Notice of final disposition. SUMMARY: FMCSA previously announced its decision to renew the exemptions from the vision... to exempt individuals from the vision requirement if the exemptions granted will not compromise...

  16. 77 FR 36336 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-18

    ...-0159] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from 10 individuals for exemption from the vision requirement in the... vision requirement. DATES: Comments must be received on or before July 18, 2012. ADDRESSES: You may...

  17. 76 FR 37168 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-24

    ...-0121] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces its decision to renew the exemptions from the vision requirement in the Federal Motor Carrier... vision requirement if the exemptions granted will not compromise safety. The Agency has concluded that...

  18. 76 FR 37173 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-24

    ...-2007-27515; FMCSA- 2008-0398; FMCSA-2009-0086] Qualification of Drivers; Exemption Applications; Vision...; request for comments. SUMMARY: FMCSA announces its decision to renew the exemptions from the vision... to exempt individuals from the vision requirement if the exemptions granted will not compromise...

  19. 77 FR 52388 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-29

    ...-0231; FMCSA-2010-0082; FMCSA-2010-0114] Qualification of Drivers; Exemption Applications; Vision AGENCY... for comments. SUMMARY: FMCSA announces its decision to renew the exemptions from the vision... to exempt individuals from the vision requirement if the exemptions granted will not compromise...

  20. 77 FR 23800 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-20

    ... Applications; Vision AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION: Notice of... from the vision requirement in the Federal Motor Carrier Safety Regulations for 11 individuals. FMCSA has statutory authority to exempt individuals from the vision requirement if the exemptions granted...

  1. 78 FR 62938 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-22

    ...-0189] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces its decision to renew the exemptions from the vision requirement in the Federal Motor Carrier... vision requirement if the exemptions granted will not compromise safety. The Agency has concluded that...

  2. 76 FR 12215 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-04

    ... Applications; Vision AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION: Notice of... from the vision requirement in the Federal Motor Carrier Safety Regulations for 21 individuals. FMCSA has statutory authority to exempt individuals from the vision requirement if the exemptions granted...

  3. 76 FR 67248 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-31

    ...-0276] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from 4 individuals for exemption from the vision requirement in the... vision standard. DATES: Comments must be received on or before November 30, 2011. ADDRESSES: You may...

  4. 76 FR 44653 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-26

    ...-9258; FMCSA-2005-21254; FMCSA-2009-0121] Qualification of Drivers; Exemption Applications; Vision...; request for comments. SUMMARY: FMCSA announces its decision to renew the exemptions from the vision... to exempt individuals from the vision requirement if the exemptions granted will not compromise...

  5. 75 FR 1450 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-11

    ... Applications; Vision AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION: Notice of... from the vision requirement in the Federal Motor Carrier Safety Regulations for 6 individuals. FMCSA has statutory authority to exempt individuals from the vision requirement if the exemptions granted...

  6. 78 FR 41188 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-09

    ...-0028] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... 25 individuals from the vision requirement in the Federal Motor Carrier Safety Regulations (FMCSRs). They are unable to meet the vision requirement in one eye for various reasons. The exemptions will...

  7. 76 FR 9865 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-22

    ...-7006; FMCSA-2006-25246; FMCSA-2006-26066] Qualification of Drivers; Exemption Applications; Vision...; request for comments. SUMMARY: FMCSA announces its decision to renew the exemptions from the vision... to exempt individuals from the vision requirement if the exemptions granted will not compromise...

  8. 77 FR 3552 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-24

    ...-0365] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from thirteen individuals for exemption from the vision requirement in the... vision requirement. DATES: Comments must be received on or before February 23, 2012. ADDRESSES: You may...

  9. 75 FR 65057 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-21

    ...-0327] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from 16 individuals for exemption from the vision requirement in the... vision standard. DATES: Comments must be received on or before November 22, 2010. ADDRESSES: You may...

  10. Hypnosis-associated blue-tinted vision: a case report

    PubMed Central

    Anbar, Ran D; Savedoff, Aaron D

    2005-01-01

    Background Self-hypnosis has been taught routinely at the SUNY Upstate Medical University for treatment of pulmonary symptoms thought to be amenable to psychological therapy. While using hypnosis for relaxation, four individuals, including a patient with cystic fibrosis, reported development of blue-tinted vision. Based on a search of the literature, we believe this is the first published report of hypnosis-associated blue-tinted vision. Case presentation The patient reported blue-tinted vision when he used hypnosis on an almost daily basis for seven years. The visual change typically occurred when he was relaxed. Moreover, a concurrent erection in the absence of sexual thoughts usually was present. The other three individuals reported blue-tinted vision after learning how to use hypnosis for relaxation as part of a group hypnosis instruction. Conclusion The blue-tinted vision experienced by the individuals in this report may be the result of an hypnosis-induced primary change in cognitive processing. Additionally, as the relaxing effect of hypnosis can be associated with a reduction in blood pressure and increased blood flow, hypnosis-associated blue-tinted vision also may be related to retinal vasodilation. PMID:16321153

  11. Individual vision and peak distribution in collective actions

    NASA Astrophysics Data System (ADS)

    Lu, Peng

    2017-06-01

    People make decisions on whether they should participate as participants or not as free riders in collective actions with heterogeneous visions. Besides of the utility heterogeneity and cost heterogeneity, this work includes and investigates the effect of vision heterogeneity by constructing a decision model, i.e. the revised peak model of participants. In this model, potential participants make decisions under the joint influence of utility, cost, and vision heterogeneities. The outcomes of simulations indicate that vision heterogeneity reduces the values of peaks, and the relative variance of peaks is stable. Under normal distributions of vision heterogeneity and other factors, the peaks of participants are normally distributed as well. Therefore, it is necessary to predict distribution traits of peaks based on distribution traits of related factors such as vision heterogeneity and so on. We predict the distribution of peaks with parameters of both mean and standard deviation, which provides the confident intervals and robust predictions of peaks. Besides, we validate the peak model of via the Yuyuan Incident, a real case in China (2014), and the model works well in explaining the dynamics and predicting the peak of real case.

  12. Your Child's Vision

    MedlinePlus

    ... 3½, kids should have eye health screenings and visual acuity tests (tests that measure sharpness of vision) ... eye rubbing extreme light sensitivity poor focusing poor visual tracking (following an object) abnormal alignment or movement ...

  13. Vision Systems with the Human in the Loop

    NASA Astrophysics Data System (ADS)

    Bauckhage, Christian; Hanheide, Marc; Wrede, Sebastian; Käster, Thomas; Pfeiffer, Michael; Sagerer, Gerhard

    2005-12-01

    The emerging cognitive vision paradigm deals with vision systems that apply machine learning and automatic reasoning in order to learn from what they perceive. Cognitive vision systems can rate the relevance and consistency of newly acquired knowledge, they can adapt to their environment and thus will exhibit high robustness. This contribution presents vision systems that aim at flexibility and robustness. One is tailored for content-based image retrieval, the others are cognitive vision systems that constitute prototypes of visual active memories which evaluate, gather, and integrate contextual knowledge for visual analysis. All three systems are designed to interact with human users. After we will have discussed adaptive content-based image retrieval and object and action recognition in an office environment, the issue of assessing cognitive systems will be raised. Experiences from psychologically evaluated human-machine interactions will be reported and the promising potential of psychologically-based usability experiments will be stressed.

  14. Occupational colour vision requirements for police officers.

    PubMed

    Birch, Jennifer; Chisholm, Catharine M

    2008-11-01

    Inclusion of public service professions in the UK Disability Discrimination Act in 2004 prompted a review of occupational colour vision requirements for police officers. Changes in the regulations which existed prior to 2003 were proposed. The aim of this study was to obtain the views of serving police officers in Northern Ireland on the importance of good colour discrimination in everyday police work and on the recruitment regulations for patrol constables introduced in 2003 in mainland UK. These views were obtained by means of a questionnaire and informal discussions. More than 65% of police officers who responded to the questionnaire considered that good colour vision was very important for effective policing. Fewer than 2% considered that colour vision was unimportant. Experienced police officers agreed that the employment of colour-deficient patrol constables, as permitted in the new regulations, would lead to reduced efficiency and organisational difficulties at the local level. A number of everyday activities were described which showed the need for accurate colour discrimination. The change in recruitment policy and the lack of clarity in the new regulations show inadequate appreciation of the needs of the occupation, of different types of colour vision anomalies and of the diagnostic function of colour vision tests. Failure to provide guidance on appropriate colour vision tests, examination procedures and counselling services is likely to result in inconsistent employment policies in different police forces. It is recommended that the colour vision standard in place prior to 2003 is reinstated at the recruitment stage. The Ishihara test should be used for screening, and colour-deficient applicants further examined with the Farnsworth D15 test as a replacement for the City University Test 2nd edition.

  15. Rapid Vision Correction by Special Operations Forces.

    PubMed

    Reynolds, Mark E

    This report describes a rapid method of vision correction used by Special Operations Medics in multiple operational engagements. Between 2011 and 2015, Special Operations Medics used an algorithm- driven refraction technique. A standard block of instruction was provided to the medics, along with a packaged kit. The technique was used in multiple operational engagements with host nation military and civilians. Data collected for program evaluation were later analyzed to assess the utility of the technique. Glasses were distributed to 230 patients with complaints of either decreased distance or near (reading). Most patients (84%) with distance complaints achieved corrected binocular vision of 20/40 or better, and 97% of patients with near-vision complaints achieved corrected near-binocular vision of 20/40 or better. There was no statistically significant difference between the percentages of patients achieving 20/40 when medics used the technique under direct supervision versus independent use. A basic refraction technique using a designed kit allows for meaningful improvement in distance and/or near vision at austere locations. Special Operations Medics can leverage this approach after specific training with minimal time commitment. It can serve as a rapid, effective intervention with multiple applications in diverse operational environments. 2017.

  16. INSIGHT: Vision & Leadership Inaugural Issue, 2001.

    ERIC Educational Resources Information Center

    McGraw, Tammy, Ed.

    2001-01-01

    This publication focuses on promising new and emerging technologies and what they might mean to the future of K-12 schools. Half of the volume contains articles devoted in some way to "Vision," and articles in the other half are under the heading of "Leadership." Contents in the "Vision" section include: "Customizable Content" (Walter Koetke);…

  17. Our Visions of Possibility for Literacy

    ERIC Educational Resources Information Center

    O'Keefe, Tim; Reinier, Rise; Gallagher, Kevin; Morgan, Bruce; Lopez-Robertson, Julia; Santman, Donna; Wong-Kam, JoAnn; Hill, Sharon; Christensen, Linda

    2006-01-01

    Tim O'Keefe, Rise Reinier and Kevin Gallagher, Bruce Morgan, Julia Lopez-Robertson, Donna Santman, JoAnn Wong-Kam, Sharon Hill, and Linda Christensen provide short essays describing their personal visions of possibility about literacy and how they maintain that passion and vision. Across a range of contexts, they reflect on the ways in which their…

  18. Dense range map reconstruction from a versatile robotic sensor system with an active trinocular vision and a passive binocular vision.

    PubMed

    Kim, Min Young; Lee, Hyunkee; Cho, Hyungsuck

    2008-04-10

    One major research issue associated with 3D perception by robotic systems is the creation of efficient sensor systems that can generate dense range maps reliably. A visual sensor system for robotic applications is developed that is inherently equipped with two types of sensor, an active trinocular vision and a passive stereo vision. Unlike in conventional active vision systems that use a large number of images with variations of projected patterns for dense range map acquisition or from conventional passive vision systems that work well on specific environments with sufficient feature information, a cooperative bidirectional sensor fusion method for this visual sensor system enables us to acquire a reliable dense range map using active and passive information simultaneously. The fusion algorithms are composed of two parts, one in which the passive stereo vision helps active vision and the other in which the active trinocular vision helps the passive one. The first part matches the laser patterns in stereo laser images with the help of intensity images; the second part utilizes an information fusion technique using the dynamic programming method in which image regions between laser patterns are matched pixel-by-pixel with help of the fusion results obtained in the first part. To determine how the proposed sensor system and fusion algorithms can work in real applications, the sensor system is implemented on a robotic system, and the proposed algorithms are applied. A series of experimental tests is performed for a variety of configurations of robot and environments. The performance of the sensor system is discussed in detail.

  19. 75 FR 25917 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-10

    ...-0082] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from 22 individuals for exemption from the vision requirement in the... vision standard. DATES: Comments must be received on or before June 9, 2010. ADDRESSES: You may submit...

  20. 76 FR 9859 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-22

    ...-7363; FMCSA-2002-13411] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor.... SUMMARY: FMCSA announces its decision to renew the exemptions from the vision requirement in the Federal... from the vision requirement if the exemptions granted will not compromise safety. The Agency has...

  1. 77 FR 23799 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-20

    ...-0040] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from 10 individuals for exemption from the vision requirement in the... vision requirement. DATES: Comments must be received on or before May 21, 2012. ADDRESSES: You may submit...

  2. 76 FR 9861 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-22

    ...; Vision AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION: Notice of renewal of... vision requirement in the Federal Motor Carrier Safety Regulations for 9 individuals. FMCSA has statutory authority to exempt individuals from the vision requirement if the exemptions granted will not compromise...

  3. 75 FR 60862 - Qualification of Drivers; Exemption Renewals; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-01

    ...-2006-24015; FMCA- 2008-0106; FMCSA-2008-0174] Qualification of Drivers; Exemption Renewals; Vision.... SUMMARY: FMCSA previously announced its decision to renew the exemptions from the vision requirement in... exempt individuals from the vision requirement if the exemptions granted will not compromise safety. The...

  4. 75 FR 39725 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-12

    ...-0161] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from 17 individuals for exemption from the vision requirement in the... vision standard. DATES: Comments must be received on or before August 11, 2010. ADDRESSES: You may submit...

  5. 76 FR 17481 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-29

    ...-0024] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from 16 individuals for exemption from the vision requirement in the... vision standard. DATES: Comments must be received on or before April 28, 2011. ADDRESSES: You may submit...

  6. 77 FR 52389 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-29

    ...-2010-0050; FMCSA- 2010-0082] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal... comments. SUMMARY: FMCSA announces its decision to renew the exemptions from the vision requirement in the... individuals from the vision requirement if the exemptions granted will not compromise safety. The Agency has...

  7. 77 FR 38381 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-27

    ...-0160] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from 10 individuals for exemption from the vision requirement in the Federal Motor Carrier Safety Regulations. They are unable to meet the vision requirement in one eye for...

  8. 77 FR 64839 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-23

    ...-0280] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from 14 individuals for exemption from the vision requirement in the Federal Motor Carrier Safety Regulations. They are unable to meet the vision requirement in one eye for...

  9. 78 FR 65032 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-30

    ...-9258; FMCSA-2011-26690] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor.... SUMMARY: FMCSA announces its decision to renew the exemptions from the vision requirement in the Federal... from the vision requirement if the exemptions granted will not compromise safety. The Agency has...

  10. 78 FR 47818 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-06

    ...-0165] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from 25 individuals for exemption from the vision requirement in the Federal Motor Carrier Safety Regulations. They are unable to meet the vision requirement in one eye for...

  11. 78 FR 62935 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-22

    ...-0166] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from 26 individuals for exemption from the vision requirement in the Federal Motor Carrier Safety Regulations. They are unable to meet the vision requirement in one eye for...

  12. 78 FR 64271 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-28

    ...-0167] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from 24 individuals for exemption from the vision requirement in the Federal Motor Carrier Safety Regulations. They are unable to meet the vision requirement in one eye for...

  13. 78 FR 22598 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-16

    ...-0026] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from 7 individuals for exemption from the vision requirement in the Federal Motor Carrier Safety Regulations. They are unable to meet the vision requirement in one eye for...

  14. 76 FR 37169 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-24

    ...-0140] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from 17 individuals for exemption from the vision requirement in the... vision standard. DATES: Comments must be received on or before July 25, 2011. ADDRESSES: You may submit...

  15. 76 FR 7894 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-11

    ...-0372] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from 19 individuals for exemption from the vision requirement in the... vision standard. DATES: Comments must be received on or before March 14, 2011. ADDRESSES: You may submit...

  16. 78 FR 1919 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-09

    ...-0339] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from 14 individuals for exemption from the vision requirement in the Federal Motor Carrier Safety Regulations. They are unable to meet the vision requirement in one eye for...

  17. 77 FR 52381 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-29

    ...-0215] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from 19 individuals for exemption from the vision requirement in the Federal Motor Carrier Safety Regulations. They are unable to meet the vision requirement in one eye for...

  18. 78 FR 64274 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-28

    ...-0169] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from 48 individuals for exemption from the vision requirement in the Federal Motor Carrier Safety Regulations. They are unable to meet the vision requirement in one eye for...

  19. 78 FR 16912 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-19

    ...-0024] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from 8 individuals for exemption from the vision requirement in the Federal Motor Carrier Safety Regulations. They are unable to meet the vision requirement in one eye for...

  20. Glaucoma patient-provider communication about vision quality-of-life

    PubMed Central

    Sleath, Betsy; Sayner, Robyn; Vitko, Michelle; Carpenter, Delesha M.; Blalock, Susan J.; Muir, Kelly W.; Giangiacomo, Annette L.; Hartnett, Mary Elizabeth; Robin, Alan L.

    2016-01-01

    Objective The purpose of this study was to: (a) describe the extent to which ophthalmologists and glaucoma patients discuss vision quality-of-life during office visits, and (b) examine the association between patient and ophthalmologist characteristics and provider-patient communication about vision quality-of-life. Methods Patients with glaucoma who were newly prescribed or on glaucoma medications were recruited at six ophthalmology clinics. Patients' visits were video-tape recorded and quality-of-life communication variables were coded. Generalized estimating equations were used to analyze the data. Results Two hundred and seventy-nine patients participated. Specific glaucoma quality-of-life domains were discussed during only 13% of visits. Older patients were significantly more likely to discuss one or more vision quality-of-life domains than younger patients. African American patients were significantly less likely to make statements about their vision quality-of-life and providers were less likely to ask them one or more vision quality-of-life questions than non-African American patients. Conclusion Eye care providers and patients infrequently discussed the patient's vision quality-of-life during glaucoma visits. African American patients were less likely to communicate about vision quality-of-life than non-African American patients. Practice Implications Eye care providers should make sure to discuss vision quality-of-life with glaucoma patients. PMID:27916461