LANDSAT TM image data quality analysis for energy-related applications
NASA Technical Reports Server (NTRS)
Wukelic, G. E.; Foote, H. P.; Petrie, G. M.; Barnard, J. C.; Eliason, J. R.
1985-01-01
This project represents a no-cost agreement between National Aeronautic Space Administration Goddard Space Flight Center (NASA GSFC) and the Pacific Northwest Laboratory (PNL). PNL is a Department of Energy (DOE) national laboratory operted by Battelle Memorial Institute at its Pacific Northwest Laboratories in Richland, Washington. The objective of this investigation is to evaluate LANDSAT's thematic mapper (TM) data quality and utility characteristics from an energy research and technological perspective. Of main interest is the extent to which repetitive TM data might support DOE efforts relating to siting, developing, and monitoring energy-related facilities, and to basic geoscientific research. The investigation utilizes existing staff and facility capabilities, and ongoing programmatic activities at PNL and other DOE national laboratories to cooperatively assess the potential usefulness of the improved experimental TM data. The investigation involves: (1) both LANDSAT 4 and 5 TM data, (2) qualitative and quantitative use consideration, and 3) NASA P (corrected) and A (uncorrected) CCT analysis for a variety of sites of DOE interest. Initial results were presented at the LANDSAT Investigator's Workshops and at specialized LANDSAT TM sessions at various conferences.
DOE Office of Scientific and Technical Information (OSTI.GOV)
King, A.G.
The Pacific Northwest Laboratory (PNL)/Analytical Chemistry Laboratory (ACL) and the Westinghouse Hanford Company (WHC)/Process Analytical Laboratory (PAL) provide analytical support services to various environmental restoration and waste management projects/programs at Hanford. In response to a US Department of Energy -- Richland Field Office (DOE-RL) audit, which questioned the comparability of analytical methods employed at each laboratory, the Sample Exchange/Exchange (SEE) program was initiated. The SEE Program is a selfassessment program designed to compare analytical methods of the PAL and ACL laboratories using sitespecific waste material. The SEE program is managed by a collaborative, the Quality Assurance Triad (Triad). Triad membershipmore » is made up of representatives from the WHC/PAL, PNL/ACL, and WHC Hanford Analytical Services Management (HASM) organizations. The Triad works together to design/evaluate/implement each phase of the SEE Program.« less
Karami, Hossein; Mazloomfard, Mohammad Mohsen; Lotfi, Behzad; Alizadeh, Asghar; Javanmard, Babak
2013-01-01
The aim of study was to evaluate the clinical outcomes of PNL in comparison with laparoscopic ureterolithotomy (LUL) in proximal ureteral stones larger than 1 cm. A total of 80 patients who were candidates for treatment of large ureteral stones in our urology center were enrolled in the study between September 2004 and September 2008. By using patient randomization, they were assigned into two forty-patient groups (PNL and LUL). After evaluating the patients with laboratory tests and IVP, PNL was performed under sonography guidance in the prone position or the patients were submitted to classic laparoscopic ureterolithotomy (LUL) transperitoneally. All patients underwent postoperative assessments including KUB and ultrasonography. A hundred-percent success was achieved in both groups. The mean age of the patients were 39.4 (16-63) and 35.2 (18-57) years old in PNL and LUL groups, respectively. The mean stone size in PNL group was 14.2 (10-25) mm and in LUL group was 13.5 (10-28) mm. The duration of the operations were 54.35 (50-82) minutes, and 82.15 (73-180) minutes (P < 0.0001); and the average hospital stay days were 2.6 (2-5) and 3.5 (3-8) days (p = 0.011) in groups PNL and LUL, accordingly. The mean Hb decrease in PNL group was 0.9mg/dL and in LUL group was 0.4mg/dL (p = 0.001). No statistically significant differences in terms of blood transfusion, fever, ICU admission, and prolonged urinary leakage were detected in both groups. According to our study, percutaneous nephrolithotomy under ultrasonography guidance is comparable with the laparoscopic ureterolithotomy for the treatment of proximal ureteral stones larger than 1 cm.
Antunes, Sérgio Luiz Gomes; Chimelli, Leila; Jardim, Márcia Rodrigues; Vital, Robson Teixeira; Nery, José Augusto da Costa; Corte-Real, Suzana; Hacker, Mariana Andréa Vilas Boas; Sarno, Euzenir Nunes
2012-03-01
Nerve biopsy examination is an important auxiliary procedure for diagnosing pure neural leprosy (PNL). When acid-fast bacilli (AFB) are not detected in the nerve sample, the value of other nonspecific histological alterations should be considered along with pertinent clinical, electroneuromyographical and laboratory data (the detection of Mycobacterium leprae DNA with polymerase chain reaction and the detection of serum anti-phenolic glycolipid 1 antibodies) to support a possible or probable PNL diagnosis. Three hundred forty nerve samples [144 from PNL patients and 196 from patients with non-leprosy peripheral neuropathies (NLN)] were examined. Both AFB-negative and AFB-positive PNL samples had more frequent histopathological alterations (epithelioid granulomas, mononuclear infiltrates, fibrosis, perineurial and subperineurial oedema and decreased numbers of myelinated fibres) than the NLN group. Multivariate analysis revealed that independently, mononuclear infiltrate and perineurial fibrosis were more common in the PNL group and were able to correctly classify AFB-negative PNL samples. These results indicate that even in the absence of AFB, these histopathological nerve alterations may justify a PNL diagnosis when observed in conjunction with pertinent clinical, epidemiological and laboratory data.
Simulation for analysis and control of superplastic forming. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zacharia, T.; Aramayo, G.A.; Simunovic, S.
1996-08-01
A joint study was conducted by Oak Ridge National Laboratory (ORNL) and the Pacific Northwest Laboratory (PNL) for the U.S. Department of Energy-Lightweight Materials (DOE-LWM) Program. the purpose of the study was to assess and benchmark the current modeling capabilities with respect to accuracy of predictions and simulation time. Two modeling capabilities with respect to accuracy of predictions and simulation time. Two simulation platforms were considered in this study, which included the LS-DYNA3D code installed on ORNL`s high- performance computers and the finite element code MARC used at PNL. both ORNL and PNL performed superplastic forming (SPF) analysis on amore » standard butter-tray geometry, which was defined by PNL, to better understand the capabilities of the respective models. The specific geometry was selected and formed at PNL, and the experimental results, such as forming time and thickness at specific locations, were provided for comparisons with numerical predictions. Furthermore, comparisons between the ORNL simulation results, using elasto-plastic analysis, and PNL`s results, using rigid-plastic flow analysis, were performed.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, J.D.
1995-11-01
The Federal Government is the largest single energy consumer in the United States; consumption approaches 1.5 quads/year of energy (1 quad = 10{sup 15} Btu) at a cost valued at nearly $10 billion annually. The US Department of Energy (DOE) Federal Energy Management Program (FEMP) supports efforts to reduce energy use and associated expenses in the Federal sector. One such effort, the New Technology Demonstration Program (NTDP), seeks to evaluate new energy-saving US technologies and secure their more timely adoption by the US Government. Pacific Northwest Laboratory (PNL) is one of four DOE national multiprogram laboratories that participate in themore » NTDP by providing technical expertise and equipment to evaluate new, energy-saving technologies being studied and evaluated under that program. This two-volume report describes a field evaluation that PNL conducted for DOE/FEMP and the US Department of Defense (DoD) Strategic Environmental Research and Development Program (SERDP) to examine the performance of a candidate energy-saving technology -- a gas-engine-driven heat pump. The unit was installed at a single residence at Fort Sam Houston, a US Army base in San Antonio, Texas, and the performance was monitored under the NTDP. Participating in this effort under a Cooperative Research and Development Agreement (CRADA) were York International, the heat pump manufacturer; Gas Research Institute (GRI), the technology developer; City Public Service of San Antonio, the local utility; American Gas Cooling Center (AGCC); Fort Sam Houston; and PNL.« less
NASA Astrophysics Data System (ADS)
Martin, P. M.; Affinito, J. D.; Gross, M. E.; Bennett, W. D.
1995-03-01
The objectives of this project were to develop and evaluate promising low-cost dielectric and polymer-protected thin-film reflective metal coatings to be applied to preformed continuously-curved solar reflector panels to enhance their solar reflectance, and to demonstrate protected solar reflective coatings on preformed solar concentrator panels. The opportunity for this project arose from a search by United Solar Technologies (UST) for organizations and facilities capable of applying reflective coatings to large preformed panels. PNL was identified as being uniquely qualified to participate in this collaborative project.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The Department of Energy Order DOE 5000.4A establishes DOE`s policy and guidelines regarding Laboratory Directed Research and Development (LDRD) at its multiprogram laboratories. As described in 5000.4A, LDRD is ``research and development of a creative and innovative nature which is selected by the Laboratory Director or his or her designee, for the purpose of maintaining the scientific and technological vitality of the Laboratory and to respond to scientific and technological opportunities in conformance with the guidelines in this Order. LDRD includes activities previously defined as ER&D, as well as other discretionary research and development activities not provided for in amore » DOE program.`` Consistent with the Mission Statement and Strategic Plan provided in PNL`s Institutional Plan, the LDRD investments are focused on developing new and innovative approaches in research related to our ``core competencies.`` Currently, PNL`s core competencies have been identified as integrated environmental research; process technology; energy systems research. In this report, the individual summaries of Laboratory-level LDRD projects are organized according to these core competencies. The largest proportion of Laboratory-level LDRD funds is allocated to the core competency of integrated environmental research. A significant proportion of PNL`s LDRD funds are also allocated to projects within the various research centers that are proposed by individual researchers or small research teams. The projects are described in Section 2.0. The projects described in this report represent PNL`s investment in its future and are vital to maintaining the ability to develop creative solutions for the scientific and technical challenges faced by DOE and the nation. In accordance with DOE guidelines, the report provides an overview of PNL`s LDRD program and the management process used for the program and project summaries for each LDRD project.« less
Geomorphic Modeling of Macro-Tidal Embayment with Extensive Tidal Flats: Skagit Bay, Washington
2010-09-30
Geomorphic modeling of macro-tidal embayment with extensive tidal flats: Skagit Bay , Washington Lyle Hibler Battelle-Pacific Northwest Division...Marine Sciences Laboratory Sequim , WA 98382 phone: (360) 681-3616 fax: (360) 681-4559 email: lyle.hibler@pnl.gov Adam Maxwell Battelle-Pacific...Northwest Division Marine Sciences Laboratory Sequim , WA 98382 phone: (360) 681-4591 fax: (360) 681-4559 email: adam.maxwell@pnl.gov Award
Technology transfer personnel exchange at the Boeing Company
DOE Office of Scientific and Technical Information (OSTI.GOV)
Antoniak, Z.I.
1993-03-01
The objective of the exchange was to transfer Pacific Northwest Laboratory (PNL) technology and expertise in advanced ceramic fabric composites (ACFC) to the Boeing Defense & Space Group (Boeing Aerospace). Boeing Aerospace was especially interested in applying PNL-developed ACFC technology to its current and future spacecraft and space missions. Boeing has on-going independent research and development (R&D) programs on advanced radiators and heat pipes, therefore, PNL research in ceramic fabric heat pipes was of particular interest to Boeing. Thus, this exchange assisted in the transfer of PNL`s ACFC heat pipe technology and other, related research capabilities to private industrial application.more » The project was proposed as an initial step in building a long-term collaborative relationship between Boeing and PNL that may result in future Cooperative Research and Development Agreements (CRADAs) and/or other types of collaborative efforts.« less
Technology transfer personnel exchange at the Boeing Company
DOE Office of Scientific and Technical Information (OSTI.GOV)
Antoniak, Z.I.
1993-03-01
The objective of the exchange was to transfer Pacific Northwest Laboratory (PNL) technology and expertise in advanced ceramic fabric composites (ACFC) to the Boeing Defense Space Group (Boeing Aerospace). Boeing Aerospace was especially interested in applying PNL-developed ACFC technology to its current and future spacecraft and space missions. Boeing has on-going independent research and development (R D) programs on advanced radiators and heat pipes, therefore, PNL research in ceramic fabric heat pipes was of particular interest to Boeing. Thus, this exchange assisted in the transfer of PNL's ACFC heat pipe technology and other, related research capabilities to private industrial application.more » The project was proposed as an initial step in building a long-term collaborative relationship between Boeing and PNL that may result in future Cooperative Research and Development Agreements (CRADAs) and/or other types of collaborative efforts.« less
Reja, Abu Hena Hasanoor; De, Abhishek; Biswas, Supratik; Chattopadhyay, Amitabha; Chatterjee, Gobinda; Bhattacharya, Basudev; Sarda, Aarti; Aggarwal, Ishad
2013-01-01
The diagnosis of pure neural leprosy (PNL) remained subjective because of over-dependence of clinical expertise and a lack of simple yet reliable diagnostic tool. The criteria for diagnosis, proposed by Jardim et al., are not routinely done by clinicians in developing country as it involves invasive nerve biopsy and sophisticated anti-PGL-1 detection. We conducted a study using fine needle aspiration cytology (FNAC) coupled with Ziehl Neelsen staining (ZN staining) and Multiplex-Polymerase Chain Reaction (PCR) specific for M. leprae for an objective diagnosis of pure neural leprosy (PNL), which may be simpler and yet reliable. The aim of the study is to couple FNAC with ZN staining and multiplex PCR to diagnose pure neural leprosy patients rapidly, in simpler and yet reliable way. Thirteen patients of PNL as diagnosed by two independent consultants were included as case, and 5 patients other than PNL were taken as control in the study. Fine needle aspiration was done on the affected nerve, and aspirates were evaluated for cytology, ZN staining and multiplex-PCR. Out of the 13 cases where fine needle aspiration was done, M. leprae could be elicited in the nerve tissue aspirates in 5 cases (38.4%) with the help of conventional acid-fast staining and 11 cases (84.6%) with the help of multiplex PCR. On cytological examination of the aspirates, only 3 (23%) cases showed specific epithelioid cells, whereas 8 (61.5%) cases showed non-specific inflammation, and 2 (15.3%) cases had no inflammatory cells. Our study demonstrates that in the field of laboratory diagnosis of PNL cases, FNAC in combination with ZN staining for acid-fast bacilli (AFB) and Multiplex-PCR can provide a rapid and definitive diagnosis for the majority of PNL cases. FNAC is a less-invasive, outdoor-based and simpler technique than invasive nerve biopsy procedure. Thus, this study may enlighten the future path for easy and reliable diagnosis of PNL.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1982-09-01
This bibliography lists publications (831 abstracts) from the Pacific Northwest Laboratory's Department of Energy sponsored research and development programs from January 1978 through July of 1982. The abstracts are grouped in subject categories, as shown in the table of contents. Entries in the subject index also facilitate access by subject, e.g., High-Level Radioactive Wastes. Three indexes, each preceded by a brief description, are provided: personal author, subject, and report number. Cited are research reports, journal articles, books, patents, theses, and conference papers. Excluded are technical progress reports. Since 1978 the Nuclear Waste Management Quarterly Progress Report has been published undermore » the series number PNL-3000. Beginning in 1982, this publication has been issued semiannually, under the series number PNL-4250. This bibliography is the successor to two others, BNWL-2201 (covering the years 1965-1976) and PNL-4050 (1975-1978). It is intended to provide a useful reference to literature in waste management written or compiled by PNL staff.« less
Percutaneous nephrolithotomy in pediatric patients: is computerized tomography a must?
Gedik, Abdullah; Tutus, Ali; Kayan, Devrim; Yılmaz, Yakup; Bircan, Kamuran
2011-02-01
The aim of this study was to retrospectively evaluate the results of pediatric percutaneous nephrolithotomy (PNL) cases, and discuss the results and necessity of non-contrast computerized tomography (CT) in these cases. In all, 48 pediatric patients who underwent PNL were retrospectively evaluated. Before PNL, either intravenous urography or CT was performed. In all patients, we evaluated the PNL time, scopy time with stone burden, and complications. During the PNL procedure, we switched to open surgery in two cases: in one because of renal pelvis perforation and in the other because of transcolonic access. In one patient who was scheduled to undergo PNL, we performed open surgery, primarily because we detected a retrorenal colon with CT. The stone burden in 45 patients who underwent PNL was 445 ± 225 mm(2), the PNL time was 51 ± 23 min, and the scopy time was 6.1 ± 2.7 min. We removed nephrostomy tubes 1-4 days after the procedure. In two patients, 24 h after removal of nephrostomy tubes, we inserted double J stents because of prolonged urine extravasation from the tract. In all, 34 of the 45 patients were stone-free, 5 patients had clinically insignificant stone fragments, and 6 patients had residual stones. PNL is a safe and effective method in the treatment of pediatric patients with kidney stones. Clinical experience is the most important factor in obtaining stone-free results. CT should be performed in all pediatric patients in order to prevent colon perforation.
Zengin, Kursad; Tanik, Serhat; Karakoyunlu, Nihat; Sener, Nevzat Can; Albayrak, Sebahattin; Tuygun, Can; Bakirtas, Hasan; Imamoglu, M Abdurrahim; Gurdal, Mesut
2015-01-01
Retrograde intrarenal surgery (RIRS) performed using a flexible ureterorenoscope marked the beginning of a new era in urology. Today, even staghorn stones are successfully treated via RIRS. The recommended treatment for larger stones is percutaneous nephrolithotomy (PNL). However, the question of whether PNL or RIRS should be the first-line treatment option for larger stones remains controversial. In this study, we contribute to the debate by comparing the success and complication rates of PNL and RIRS that were used to treat renal pelvis stones 2-3 cm in diameter. The medical records of 154 patients (74 PNL, 80 RIRS) were retrospectively evaluated. PNL patients were placed in Group 1 and RIRS patients in Group 2. The complete stone-free rates were 95.5% in the PNL group and 80.6% in the RIRS group 1 month postoperatively (P = 0.061). The respective complication rates (evaluated using the Clavien system) were 13.5% and 8.8% (P = 0.520). RIRS affords a comparable success rate, causes fewer complications than PNL, and seems to be a promising alternative to PNL when larger stones are to be treated. Prospective randomized controlled trials are needed to confirm these findings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Winiarski, D.W.
1995-01-01
The federal government is the largest single energy consumer in the United States cost valued at nearly $10 billion annually. The US Department of Energy`s (DOE) Federal Energy Management Program (FEMP) supports efforts to reduce energy use and associated expenses in the federal sector. One such effort, the New Technology Demonstration Program (NTDP), seeks to evaluate new energy-saving US technologies and secure their more timely adoption by the US government. Pacific Northwest Laboratory (PNL) is one of four DOE laboratories that participate in the New Technologies Demonstration Program, providing technical expertise and equipment to evaluate new, energy-saving technologies being studiedmore » under that program. This interim report provides the results of a field evaluation that PNL conducted for DOE/FEMP and the US Department of Defense (DoD) Strategic Environmental Research and Development Program (SERDP) to examine the performance of a candidate energy-saving technology-a hot water heater conversion system to convert electrically heated hot water tanks to natural gas fuel. The unit was installed at a single residence at Fort Stewart, a US Army base in Georgia, and the performance was monitored under the NTDP. Participating in this effort under a Cooperative Research and Development Agreement (CRADA) were Gas Fired Products, developers of the technology; the Public Service Company of North Carolina; Atlanta Gas Light Company; the Army Corps of Engineers; Fort Stewart; and Pacific Northwest Laboratory.« less
Preliminary testing of turbulence and radionuclide transport modeling in deep ocean environment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Onishi, Y.; Dummuller, D.C.; Trent, D.S.
Pacific Northwest Laboratory (PNL) performed a study for the US Environmental Protection Agency's Office of Radiation Programs to (1) identify candidate models for regional modeling of low-level waste ocean disposal sites in the mid-Atlantic ocean; (2) evaluate mathematical representation of the model's eddy viscosity/dispersion coefficients; and (3) evaluate the adequacy of the k-{epsilon} turbulence model and the feasibility of one of the candidate models, TEMPEST{copyright}/FLESCOT{copyright}, to deep-ocean applications on a preliminary basis. PNL identified the TEMPEST{copyright}/FLESCOT{copyright}, FLOWER, Blumberg's, and RMA 10 models as appropriate candidates for the regional radionuclide modeling. Among these models, TEMPEST/FLESCOT is currently the only model thatmore » solves distributions of flow, turbulence (with the k-{epsilon} model), salinity, water temperature, sediment, dissolved contaminants, and sediment-sorbed contaminants. Solving the Navier-Stokes equations using higher order correlations is not practical for regional modeling because of the prohibitive computational requirements; therefore, the turbulence modeling is a more practical approach. PNL applied the three-dimensional code, TEMPEST{copyright}/FLESCOT{copyright} with the k-{epsilon} model, to a very simple, hypothetical, two-dimensional, deep-ocean case, producing at least qualitatively appropriate results. However, more detailed testing should be performed for the further testing of the code. 46 refs., 39 figs., 6 tabs.« less
Cleanup Verification Package for the 118-F-5 PNL Sawdust Pit
DOE Office of Scientific and Technical Information (OSTI.GOV)
L. D. Habel
2008-05-20
This cleanup verification package documents completion of remedial action, sampling activities, and compliance with cleanup criteria for the 118-F-5 Burial Ground, the PNL (Pacific Northwest Laboratory) Sawdust Pit. The 118-F-5 Burial Ground was an unlined trench that received radioactive sawdust from the floors of animal pens in the 100-F Experimental Animal Farm.
Totally tubeless percutaneous nephrolithotomy: is it safe and effective in preschool children?
Ozturk, Ahmet; Guven, Selcuk; Kilinc, Mehmet; Topbaş, Emrah; Piskin, Mesut; Arslan, Mehmet
2010-12-01
After the introduction of tubeless percutaneous nephrolithotomy (PNL), many studies conducted in adult patients have confirmed its efficacy and safety. There are limited studies reporting that tubeless PNL can be safely applied in children, however. Furthermore, there are no reports that evaluate the use of totally tubeless PNL in children. The present study evaluates the results of totally tubeless PNL in preschool children. The data of children seen in our clinic who were considered suitable for totally tubeless PNL were analyzed. Of 16 children, 8 patients underwent totally tubeless PNL (group 1) and 8 standard PNL (group 2). The two groups of patients were compared with regard to length of hospitalization, analgesic requirements, transfusion rates, hemoglobin (Hb) decrease, and immediate, early, and late complications. The mean ages of the patients were 56.6 months (9-84 mos) and 56.0 months (5-84 mos), and the mean follow-up was 21.5 months (3-44 mos) and 43.4 months (36-54 mos) in groups 1 and 2, respectively. Both groups were similar with regard to age, stone size, Hb change, and complications. Although operation duration, hospitalization period, and analgesic requirement were less in the totally tubeless PNL group, these differences were not statistically significant. The latest application of PNL, totally tubeless PNL, is also a safe and effective procedure in very small children if they are selected properly and if the surgeon has sufficient experience with the procedure. More studies with a higher number of participants are needed, however, to confirm that totally tubeless PNL increases the comfort of pediatric patients, decreases their hospitalization period, and is more economical.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McElroy, W.N.; Kellogg, L.S.; Matsumoto, W.Y.
1988-05-01
This report is in response to a request from Westinghouse Hanford Company (WHC) that the PNL National Dosimetry Center (NDC) perform physics-dosimetry analyses (E > MeV) for N Reactor Pressure Tubes 2954 and 3053. As a result of these analyses, and recommendations for additional studies, two physics-dosimetry re-evaluations for Pressure Tube 1165 were also accomplished. The primary objective of Pacific Northwest Laboratories' (PNL) National Dosimetry Center (NDC) physics-dosimetry work for N Reactor was to provide FERRET-SAND II physics-dosimetry results to assist in the assessment of neutron radiation-induced changes in the physical and mechanical properties of N Reactor pressure tubes. 15more » refs., 6 figs., 5 tabs.« less
Zengin, Kursad; Tanik, Serhat; Sener, Nevzat Can; Albayrak, Sebahattin; Tuygun, Can; Bakirtas, Hasan; Imamoglu, M. Abdurrahim; Gurdal, Mesut
2015-01-01
Objective. Retrograde intrarenal surgery (RIRS) performed using a flexible ureterorenoscope marked the beginning of a new era in urology. Today, even staghorn stones are successfully treated via RIRS. The recommended treatment for larger stones is percutaneous nephrolithotomy (PNL). However, the question of whether PNL or RIRS should be the first-line treatment option for larger stones remains controversial. In this study, we contribute to the debate by comparing the success and complication rates of PNL and RIRS that were used to treat renal pelvis stones 2-3 cm in diameter. Materials and Methods. The medical records of 154 patients (74 PNL, 80 RIRS) were retrospectively evaluated. PNL patients were placed in Group 1 and RIRS patients in Group 2. Results. The complete stone-free rates were 95.5% in the PNL group and 80.6% in the RIRS group 1 month postoperatively (P = 0.061). The respective complication rates (evaluated using the Clavien system) were 13.5% and 8.8% (P = 0.520). Conclusions. RIRS affords a comparable success rate, causes fewer complications than PNL, and seems to be a promising alternative to PNL when larger stones are to be treated. Prospective randomized controlled trials are needed to confirm these findings. PMID:25821828
Beyond prone position in percutaneous nephrolithotomy: a comprehensive review.
de la Rosette, Jean J M C H; Tsakiris, Peter; Ferrandino, Michael N; Elsakka, Ahmed M; Rioja, Jorge; Preminger, Glenn M
2008-12-01
Percutaneous nephrolithotomy (PNL) is traditionally performed with the patient in the prone position. To assess the efficacy and safety of the prone and supine positions, particularly in obese patients and in those with staghorn calculi. A Medline search was conducted for articles published during the last 10 yr related to PNL in the prone and supine positions. This search revealed 9 published studies for supine and 25 for prone PNL. None of the supine PNL studies reported visceral injuries, while transfusion rates were 0.0-9.4% and stone-free rates were 69.6-95.0%. One study of supine PNL evaluated a significant proportion of obese patients. Prone PNL studies in obese patients report transfusion rates of 3.2-8.8% and stone-free rates of 79.0-89.2%. In the only randomized study, excluding obese patients and staghorn calculi, operative time favors the supine position. A nonrandomized comparative study demonstrated similar complication rates with insignificant improvement in treatment success for supine PNL; however, when comparing series with similar proportions of staghorn calculi cases, there are slightly improved outcomes for prone PNL. Moreover, comparison of weighted means favors prone PNL. For obese patients and staghorn calculi, prone PNL appears to be associated with decreased operative times with similar bleeding rates and slightly better stone-free rates than supine PNL.
Vandenberg Air Force Base integrated resource assessment. Volume 3, Resource assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daellenbach, K.K.; Dagle, J.E.; Dittmer, A.L.
1993-06-01
The US Air Force Space Command (SPACECOM) has tasked the Pacific Northwest Laboratory (PNL), as the lead laboratory supporting the US Department of Energy (DOE) Federal Energy Management Program (FEMP), to identify, evaluate, and assist in acquiring all cost-effective energy projects at Vandenberg Air Force Base (VAFB). This is part of a model program that PNL is designing to support energy-use decisions in the federal sector. This report provides the results of the fossil fuel and electric energy resource opportunity (ERO) assessments performed by PNL at the SPACECOM VAFB facility located approximately 50 miles northwest of Santa Barbara, California. Itmore » is a companion report to Volume 1, Executive Summary, and Volume 2, Baseline Detail. The results of the analysis of EROs are presented in ten common energy end-use categories (e.g., boilers and furnaces, service hot water, and building lighting). In addition, a case study of process loads at Space Launch Complex-4 (SLC-4) is included. A narrative description of each ERO is provided, including information on the installed cost, energy and dollar savings; impacts on operation and maintenance (O and M); and, when applicable, a discussion of energy supply and demand, energy security, and environmental issues. A description of the evaluation methodologies and technical and cost assumptions is also provided for each ERO. Summary tables present the cost-effectiveness of energy end-use equipment before and after the implementation of each ERO and present the results of the life-cycle cost (LCC) analysis indicating the net present value (NPV) and value index (VI) of each ERO. Finally, an appendix includes a summary of an economic analysis case study of the South Vandenberg Power Plant (SVPP) operating scenarios.« less
Guven, Selcuk; Istanbulluoglu, Okan; Ozturk, Ahmet; Ozturk, Bulent; Piskin, Mesut; Cicek, Tufan; Kilinc, Mehmet; Ozkardes, Hakan; Arslan, Mehmet
2010-01-01
We aimed to evaluate the efficacy and safety of percutaneous nephrolithotomy (PNL) in infants and small children (12-36 months). The PNL applications conducted in children <3 years of age in two centers were evaluated. Whereas pediatric PNL instrumentation was used in the first center, adult-size instrumentation was utilized in the second center. The complications were given according to the modified Clavien classification system. The mean age of the patients was 22.76 months (5-36 months) and the mean body weight was 11.51 kg (6-15 kg). In twelve renal units, pediatric instrumentation was used and among these, two had miniperc. In the other eight renal units, adult-size instrumentation was employed. Except for the patient with complex renal stones, all patients were stone free after the intervention and none required a conversion to open surgery. There were grade 1-2 complications in 3 patients. The postoperative hemoglobin drop was greater in the children who underwent PNL with adult-size instrumentation. In this young age group, in addition to standard PNL, simultaneous bilateral PNL, tubeless PNL and in urgent cases of renal failure, urgent PNL, are safe and effective treatment modalities provided patients are selected properly and the surgeon performing the procedure has the necessary experience. Copyright © 2010 S. Karger AG, Basel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Winiarski, D.W.
1995-12-01
The Federal government is the largest single energy consumer in the United States with consumption of nearly 1.5 quads/year of energy (10{sup 15} quad = 1015 Btu) and cost valued at nearly $10 billion annually. The US Department of Energy`s (DOE) Federal Energy Management Program (FEMP) supports efforts to reduce energy use and associated expenses in the Federal sector. One such effort, the New Technology Demonstration Program (NTDP) seeks to evaluate new energy -- saving US technologies and secure their more timely adoption by the US government. Pacific Northwest Laboratory (PNL) is one of four DOE laboratories that participate inmore » the New Technologies Demonstration Program, providing technical expertise and equipment to evaluate new, energy-saving technologies being studied under that program. This report provides the results of a field evaluation that PNL conducted for DOE/FEMP with funding support from the US Department of Defense (DoD) Strategic Environmental Research and Development Program (SERDP) to examine the performance of 4 candidate energy-saving technology-a water heater conversion system to convert electrically powered water heaters to natural gas fuel. The unit was installed at a single residence at Fort Stewart, a US Army base in Georgia, and the performance was monitored under the NTDP. Participating in this effort under a Cooperative Research and Development Agreement (CRADA) were Gas Fired Products, developers of the technology; the Public Service Company of North Carolina; Atlanta Gas Light Company; the Army Corps of Engineers; Fort Stewart; and Pacific Northwest Laboratory.« less
Solid waste projection model: Model version 1. 0 technical reference manual
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilkins, M.L.; Crow, V.L.; Buska, D.E.
1990-11-01
The Solid Waste Projection Model (SWPM) system is an analytical tool developed by Pacific Northwest Laboratory (PNL) for Westinghouse Hanford Company (WHC). The SWPM system provides a modeling and analysis environment that supports decisions in the process of evaluating various solid waste management alternatives. This document, one of a series describing the SWPM system, contains detailed information regarding the software utilized in developing Version 1.0 of the modeling unit of SWPM. This document is intended for use by experienced software engineers and supports programming, code maintenance, and model enhancement. Those interested in using SWPM should refer to the SWPM Modelmore » User's Guide. This document is available from either the PNL project manager (D. L. Stiles, 509-376-4154) or the WHC program monitor (B. C. Anderson, 509-373-2796). 8 figs.« less
Comparative Study between Standard and Totally Tubeless Percutaneous Nephrolithotomy.
Yun, Sung Il; Lee, Yoon Hyung; Kim, Jae Soo; Cho, Sung Ryong; Kim, Bum Soo; Kwon, Joon Beom
2012-11-01
Several recent studies have reported the benefits of tubeless percutaneous nephrolithotomy (PNL). Postoperatively, tubeless PNL patients have an indwelling ureteral stent placed, which is often associated with stent-related morbidity. We have performed totally tubeless (tubeless and stentless) PNL in which no nephrostomy tube or ureteral stent is placed postoperatively. We evaluated the safety, effectiveness, and feasibility of totally tubeless PNL. From March 2008 to February 2012, 57 selected patients underwent standard or totally tubeless PNL. Neither a nephrostomy tube nor a ureteral stent was placed in the totally tubeless PNL group. We compared patient and stone characteristics, operation time, length of hospitalization, analgesia requirements, stone-free rate, blood loss, change in creatinine, and perioperative complications between the standard and totally tubeless PNL groups. There were no significant differences in preoperative patient characteristics, postoperative complications, or the stone-free rate between the two groups, but the totally tubeless PNL group showed a shorter hospitalization and a lesser analgesic requirement compared with the standard PNL group. Blood loss and change in creatinine were not significantly different between the two groups. Totally tubeless PNL appears to be a safe and effective alternative for the management of renal stone patients and is associated with a decrease in length of hospital stay.
Comparative Study between Standard and Totally Tubeless Percutaneous Nephrolithotomy
Yun, Sung Il; Lee, Yoon Hyung; Kim, Jae Soo; Cho, Sung Ryong; Kim, Bum Soo
2012-01-01
Purpose Several recent studies have reported the benefits of tubeless percutaneous nephrolithotomy (PNL). Postoperatively, tubeless PNL patients have an indwelling ureteral stent placed, which is often associated with stent-related morbidity. We have performed totally tubeless (tubeless and stentless) PNL in which no nephrostomy tube or ureteral stent is placed postoperatively. We evaluated the safety, effectiveness, and feasibility of totally tubeless PNL. Materials and Methods From March 2008 to February 2012, 57 selected patients underwent standard or totally tubeless PNL. Neither a nephrostomy tube nor a ureteral stent was placed in the totally tubeless PNL group. We compared patient and stone characteristics, operation time, length of hospitalization, analgesia requirements, stone-free rate, blood loss, change in creatinine, and perioperative complications between the standard and totally tubeless PNL groups. Results There were no significant differences in preoperative patient characteristics, postoperative complications, or the stone-free rate between the two groups, but the totally tubeless PNL group showed a shorter hospitalization and a lesser analgesic requirement compared with the standard PNL group. Blood loss and change in creatinine were not significantly different between the two groups. Conclusions Totally tubeless PNL appears to be a safe and effective alternative for the management of renal stone patients and is associated with a decrease in length of hospital stay. PMID:23185671
2013-01-01
Background Critical illness polyneuropathy (CIP) and critical illness myopathy (CIM) are complications causing weakness of respiratory and limb muscles in critically ill patients. As an important differential diagnosis of Guillain-Barré syndrome (GBS), CIP and CIM should be diagnosed with caution, after a complete clinical and laboratory examination. Although not uncommon in ICU, CIP and CIM as severe complications of percutaneous nephrostolithotomy (PNL) have not been documented in literature. Case presentation A 48-year-old Chinese woman was referred to our hospital, complaining of occasional pain in the right lower back for one month. Lithiasis was diagnosed by ultrasonographical and radiological examinations on the urinary system. PNL was indicated and performed. The patient developed CIP and CIM on the fourth day after PNL. Early recognition and treatment of the severe complications contributed to a satisfactory recovery of the patient. Conclusion This case expands our understanding of the complications of PNL and underscores the importance of differentiating CIP/CIM from GBS in case of such patients developing weakness after the treatment. Clinical characteristics and examination results should be carefully evaluated to make the diagnosis of CIP or CIM. Both anti-septic prophylaxis and control of hyperglycemia might be effective for the prevention of CIP or CIM; aggressive treatment on sepsis and multiple organ failure is considered to be the most effective measure to reduce the incidence of CIP/CIM. PMID:23409743
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bills, K.C.; Kress, R.L.; Kwon, D.S.
1994-12-31
This paper describes ORNL`s development of an environment for the simulation of robotic manipulators. Simulation includes the modeling of kinematics, dynamics, sensors, actuators, control systems, operators, and environments. Models will be used for manipulator design, proposal evaluation, control system design and analysis, graphical preview of proposed motions, safety system development, and training. Of particular interest is the development of models for robotic manipulators having at least one flexible link. As a first application, models have been developed for the Pacific Northwest Laboratory`s Flexible Beam Test Bed (PNL FBTB), which is a 1-Degree-of-Freedom, flexible arm with a hydraulic base actuator. ORNLmore » transferred control algorithms developed for the PNL FBTB to controlling IGRIP models. A robust notch filter is running in IGRIP controlling a full dynamics model of the PNL test bed. Model results provide a reasonable match to the experimental results (quantitative results are being determined) and can run on ORNL`s Onyx machine in approximately realtime. The flexible beam is modeled as six rigid sections with torsional springs between each segment. The spring constants were adjusted to match the physical response of the flexible beam model to the experimental results. The controller is able to improve performance on the model similar to the improvement seen on the experimental system. Some differences are apparent, most notably because the IGRIP model presently uses a different trajectory planner than the one used by ORNL on the PNL test bed. In the future, the trajectory planner will be modified so that the experiments and models are the same. The successful completion of this work provides the ability to link C code with IGRIP, thus allowing controllers to be developed, tested, and tuned in simulation and then ported directly to hardware systems using the C language.« less
NASA Astrophysics Data System (ADS)
Winkel, B. V.
1995-03-01
The purpose of this report is to document the Multi-Function Waste Tank Facility (MWTF) Project position on the concrete mechanical properties needed to perform design/analysis calculations for the MWTF secondary concrete structure. This report provides a position on MWTF concrete properties for the Title 1 and Title 2 calculations. The scope of the report is limited to mechanical properties and does not include the thermophysical properties of concrete needed to perform heat transfer calculations. In the 1970's, a comprehensive series of tests were performed at Construction Technology Laboratories (CTL) on two different Hanford concrete mix designs. Statistical correlations of the CTL data were later generated by Pacific Northwest Laboratories (PNL). These test results and property correlations have been utilized in various design/analysis efforts of Hanford waste tanks. However, due to changes in the concrete design mix and the lower range of MWTF operating temperatures, plus uncertainties in the CTL data and PNL correlations, it was prudent to evaluate the CTL data base and PNL correlations, relative to the MWTF application, and develop a defendable position. The CTL test program for Hanford concrete involved two different mix designs: a 3 kip/sq in mix and a 4.5 kip/sq in mix. The proposed 28-day design strength for the MWTF tanks is 5 kip/sq in. In addition to this design strength difference, there are also differences between the CTL and MWTF mix design details. Also of interest, are the appropriate application of the MWTF concrete properties in performing calculations demonstrating ACI Code compliance. Mix design details and ACI Code issues are addressed in Sections 3.0 and 5.0, respectively. The CTL test program and PNL data correlations focused on a temperature range of 250 to 450 F. The temperature range of interest for the MWTF tank concrete application is 70 to 200 F.
Continuous AE crack monitoring of a dissimilar metal weldment at Limerick Unit 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hutton, P.H.; Friesel, M.A.; Dawson, J.F.
1993-12-01
Acoustic emission (AE) technology for continuous surveillance of a reactor component(s) to detect crack initiation and/or crack growth has been developed at Pacific Northwest Laboratory (PNL). The technology was validated off-reactor in several major tests, but it had not been validated by monitoring crack growth on an operating reactor system. A flaw indication was identified during normal inservice inspection of piping at Philadelphia Electric Company (PECO) Limerick Unit 1 reactor during the 1989 refueling outage. Evaluation of the flaw indication showed that it could remain in place during the subsequent fuel cycle without compromising safety. The existence of this flawmore » indication offered a long sought opportunity to validate AE surveillance to detect and evaluate crack growth during reactor operation. AE instrumentation was installed by PNL and PECO to monitor the flaw indication during two complete fuel cycles. This report discusses the results obtained from the AE monitoring over the period May 1989 to March 1992 (two fuel cycles).« less
Eryildirim, Bilal; Tuncer, Murat; Camur, Emre; Ustun, Fatih; Tarhan, Fatih; Sarica, Kemal
2017-10-03
To evaluate the true necessity of open end ureteral catheter insertion in patients with moderate to severe pelvicalyceal system dilation treated with percutaneous nephrolithotomy (PNL) under sonographic guidance. 50 cases treated with PNL under sonographic guidance in prone position for solitary obstructing renal stones were evaluated. Patients were randomly divided into two groups; Group 1: Patients in whom a open end ureteral catheter was inserted prior to the procedure; Group 2: Patients receiving no catheter before PNL. In addition to the duration of the procedure as a whole and also all relevant stages as well, radiation exposure time, hospitalization period, mean nephrostomy tube duration, mean drop in Hb levels and all intra and postoperative complications have been evaluated. Mean size of the stones was 308.5 ± 133.2 mm2. Mean total duration of the PNL procedure in cases with open end ureteral catheter was significantly longer than the other cases (p < 0.001). Evaluation of the outcomes of the PNL procedures revealed no statistically significant difference between two groups regarding the stone-free rates (86% vs 84%). Additionally, there was no significant difference with respect to the duration of nephrostomy tube, hospitalization period and secondary procedures needed, complication rates as well as the post-operative Hb drop levels in both groups (p = 0.6830). Our results indicate that the placement of an open end ureteral catheter prior to a PNL procedure performed under sonographic access may not be indicated in selected cases presenting with solitary obstructing renal pelvic and/or calyceal stones.
Recommendations for the treatment of aging in standard technical specifications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Orton, R.D.; Allen, R.P.
1995-09-01
As part of the US Nuclear Regulatory Commission`s Nuclear Plant Aging Research Program, Pacific Northwest Laboratory (PNL) evaluated the standard technical specifications for nuclear power plants to determine whether the current surveillance requirements (SRs) were effective in detecting age-related degradation. Nuclear Plant Aging Research findings for selected systems and components were reviewed to identify the stressors and operative aging mechanisms and to evaluate the methods available to detect, differentiate, and trend the resulting aging degradation. Current surveillance and testing requirements for these systems and components were reviewed for their effectiveness in detecting degraded conditions and for potential contributions to prematuremore » degradation. When the current surveillance and testing requirements appeared ineffective in detecting aging degradation or potentially could contribute to premature degradation, a possible deficiency in the SRs was identified that could result in undetected degradation. Based on this evaluation, PNL developed recommendations for inspection, surveillance, trending, and condition monitoring methods to be incorporated in the SRs to better detect age- related degradation of these selected systems and components.« less
Singh, Vishwajeet; Sinha, Rahul Janak; Sankhwar, S N; Malik, Anita
2011-01-01
A prospective randomized study was executed to compare the surgical parameters and stone clearance in patients who underwent percutaneous nephrolithotomy (PNL) under combined spinal-epidural anesthesia (CSEA) versus those who underwent PNL under general anesthesia (GA). Between January 2008 to December 2009, 64 patients with renal calculi were randomized into 2 groups and evaluated for the purpose of this study. Group 1 consisted of patients who underwent PNL under CSEA and Group 2 consisted of patients who underwent PNL under GA. The operative time, stone clearance rate, visual pain analog score, mean analgesic dose and mean hospital stay were compared amongst other parameters. The difference between visual pain analog score after the operation and the dose of analgesic requirement was significant on statistical analysis between both groups. PNL under CSEA is as effective and safe as PNL under GA. Patients who undergo PNL under CESA require lesser analgesic dose and have a shorter hospital stay. Copyright © 2011 S. Karger AG, Basel.
Cho, Kyu-Sup; Kang, Dae-Woon; Kim, Hak-Jin; Lee, Jong-Kil; Roh, Hwan-Jung
2012-04-01
No study has done a comparative analysis of radiologic imaging findings between primary nasopharyngeal lymphoma (PNL) and nasopharyngeal carcinoma (NPC). The purpose of this study was to analyze computed tomography (CT) and magnetic resonance (MR) images and to evaluate the maximum standardized uptake value (SUV max) of positron emission tomography (PET)/CT between PNL and NPC, knowing the imaging features that distinguish PNL from NPC. Cross-sectional study. University tertiary care facility. The authors analyzed the features on CT, MR imaging, and PET/CT of 16 patients diagnosed with PNL and 32 patients diagnosed with NPC histopathologically. Patients with PNL had a larger tumor volume and showed symmetry of tumor shape than did patients with NPC. Patients with PNL also had higher tumor homogeneity than NPC patients on CT, T2-weighted, and postcontrast MR images. All PNL patients showed a high degree of enhancement without invasion to the adjacent deep structure. The involvement of the Waldeyer ring was significantly higher in PNL patients. Cervical and retropharyngeal lymphadenopathy and PET/CT SUV max showed no significant difference between PNL and NPC. If the images present a bulky, symmetric nasopharyngeal mass with marked homogeneity, a high degree of enhancement, and a higher Waldeyer ring involvement combined with no invasion into the deep structure, PNL should be considered over NPC.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, J.F.
1986-02-01
This report summarizes progress on OHER biomedical and health-effects research conducted at PNL in FY 1985 to develop information for a comprehensive understanding of the interaction of energy-related radiation and chemicals with man. Our continuing emphasis on decreasing the uncertainty of health-effects risk estimates to man from existing and/or developing energy-related technologies supports the DOE goal of increasing and diversifying national energy resources and decreasing risks to human health. The report is arranged to reflect the PNL research relative to OHER programmatic needs. The first section concerns evaluation of possible health effects among nuclear workers. The next two sections, whichmore » contain reports of health-effects research in biological systems, include health effects of radiation and health effects of chemical mixtures. The last section is related to medical applications of nuclear technology.« less
Kirac, Mustafa; Bozkurt, Ömer Faruk; Tunc, Lutfi; Guneri, Cagri; Unsal, Ali; Biri, Hasan
2013-06-01
The aim of this study was to compare the outcomes of retrograde intrarenal surgery (RIRS) and miniaturized percutaneous nephrolithotomy (mini-PNL) in management of lower-pole renal stones with a diameter smaller than 15 mm. Between December 2009 and July 2012, the patients with the diagnosis of lower-pole stones were evaluated by ultrasonography, intravenous pyelography and computed tomography. The records of 73 evaluable patients who underwent mini-PNL (n = 37) or RIRS (n = 36) for lower-pole (LP) stones with diameter smaller than 15 mm were reviewed retrospectively. Of the 73 patients, 37 underwent mini-PNL and 36 underwent RIRS. The stone-free rates were 89.1 and 88.8 % for mini-PNL and RIRS groups, respectively. The mean operation time was 53.7 ± 14.5 in the mini-PNL group but 66.4 ± 15.8 in the RIRS group (P = 0.01). The mean fluoroscopy times and hospitalization times were significantly higher in the mini-PNL group. There was no major complication in any patient. RIRS and mini-PNL are safe and effective methods for treatment of LP calculi with a diameter smaller than 15 mm. RIRS is a non-invasive and feasible treatment option, and has also short hospitalization time, low morbidity and complication rate. It may be an alternative of mini-PNL in the treatment LP calculi with smaller than 15 mm.
NASA Technical Reports Server (NTRS)
Berard, Peter R.
1993-01-01
Researchers in the Molecular Sciences Research Center (MSRC) of Pacific Northwest Laboratory (PNL) currently generate massive amounts of scientific data. The amount of data that will need to be managed by the turn of the century is expected to increase significantly. Automated tools that support the management, maintenance, and sharing of this data are minimal. Researchers typically manage their own data by physically moving datasets to and from long term storage devices and recording a dataset's historical information in a laboratory notebook. Even though it is not the most efficient use of resources, researchers have tolerated the process. The solution to this problem will evolve over the next three years in three phases. PNL plans to add sophistication to existing multilevel file system (MLFS) software by integrating it with an object database management system (ODBMS). The first phase in the evolution is currently underway. A prototype system of limited scale is being used to gather information that will feed into the next two phases. This paper describes the prototype system, identifies the successes and problems/complications experienced to date, and outlines PNL's long term goals and objectives in providing a permanent solution.
NASA Astrophysics Data System (ADS)
Anheier, N. C., Jr.; McDonald, C. E.; Cuta, J. M.; Cuta, F. M.; Olsen, K. B.
1995-05-01
This report describes an evaluation of various sensing techniques for determining the ammonia concentration in the working fluid of ammonia/water absorption cycle systems. The purpose was to determine if any existing sensor technology or instrumentation could provide an accurate, reliable, and cost-effective continuous measure of ammonia concentration in water. The resulting information will be used for design optimization and cycle control in an ammonia-absorption heat pump. Pacific Northwest Laboratory (PNL) researchers evaluated each sensing technology against a set of general requirements characterizing the potential operating conditions within the absorption cycle. The criteria included the physical constraints for in situ operation, sensor characteristics, and sensor application. PNL performed an extensive literature search, which uncovered several promising sensing technologies that might be applicable to this problem. Sixty-two references were investigated, and 33 commercial vendors were identified as having ammonia sensors. The technologies for ammonia sensing are acoustic wave, refractive index, electrode, thermal, ion-selective field-effect transistor (ISFET), electrical conductivity, pH/colormetric, and optical absorption. Based on information acquired in the literature search, PNL recommends that follow-on activities focus on ISFET devices and a fiber optic evanescent sensor with a colormetric indicator. The ISFET and fiber optic evanescent sensor are inherently microminiature and capable of in situ measurements. Further, both techniques have been demonstrated selective to the ammonium ion (NH4(+)). The primary issue remaining is how to make the sensors sufficiently corrosion-resistant to be useful in practice.
Gökce, Mehmet İlker; Ibiş, Arif; Sancı, Adem; Akıncı, Aykut; Bağcı, Uygar; Ağaoğlu, Eylül Asya; Süer, Evren; Gülpınar, Ömer
2017-12-01
Percutaneous nephrolithotomy (PNL) is the primary treatment modality for management of staghorn stones. PNL in supine position has important advantages over prone positon. However, studies comparing prone and supine positions for PNL in staghorn stone patients have conflicting results, and the aim of the current study was to compare prone and supine positions for PNL in staghorn stone cases. Data of patients underwent PNL for staghorn stones in supine or prone position by a single urologist were collected prospectively. The supine and prone position groups were compared for stone free rate (SFR) and complication rates. All patients were evaluated with NCCT for evaluation of SFR. Chi-square test was used to compare categorical variables and Student t test was applied for continuous variables of the treatment groups. The groups were similar for demographic and stone-related characteristics. Multi-caliceal and intercostal access was more common in prone position. Operation duration was significantly shorter and hemoglobin drop was significantly less in supine group. SFR was 64.1 and 60.4% in the supine and prone groups, respectively (p = 0.72). Complication rates were similar in the two groups but Clavien III complications were observed in two patients in the prone group. PNL in supine position is an effective treatment for management of staghorn stones. The need for multi-caliceal and intercostal puncture is less when combined with retrograde intrarenal surgery. PNL in supine position should be considered as primary treatment option in staghorn stone cases.
Resorlu, Berkan; Unsal, Ali; Ziypak, Tevfik; Diri, Akif; Atis, Gokhan; Guven, Selcuk; Sancaktutar, Ahmet Ali; Tepeler, Abdulkadir; Bozkurt, Omer Faruk; Oztuna, Derya
2013-12-01
To compare the outcomes of shock wave lithotripsy (SWL), percutaneous nephrolithotomy (PNL), and retrograde intrarenal surgery (RIRS) for 10-20 mm radiolucent renal calculi by evaluating stone-free rates and associated complications. A total of 437 patients at 7 institutions who underwent SWL (n = 251), PNL (n = 140), or RIRS (n = 46) were enrolled in our study. Clinical success was defined as stone-free status or asymptomatic insignificant residual fragments <3 mm. The success rates, auxiliary procedures, and complications were compared in each group. Success rates were 66.5, 91.4, and 87% for SWL, PNL, and RIRS (p < 0.001). The need for auxiliary procedures was more common after SWL than PNL and RIRS (21.9 vs 5.7 vs 8.7%, respectively; p < 0.001). The overall complication rates for the SWL, PNL, and RIRS were 7.6, 22.1, and 10.9%, respectively (p < 0.001). Thirteen patients in PNL group received blood transfusions, while none of the patients in RIRS and SWL groups transfused. Hospitalization time per patient was 1.3 ± 0.5 days in the RIRS group, while it was 2.6 ± 0.9 days in the PNL group (p < 0.001). Fluoroscopy and operation time were significantly longer in the PNL group compared to RIRS (145.7 ± 101.7 vs 28.7 ± 18.7 s, and 57.5 ± 22.1 vs 43.1 ± 17 min, respectively). For treatment of moderate-sized radiolucent renal stones, RIRS and PNL provide significantly higher success and lower retreatment rate compared with SWL. Although PNL is effective, its biggest drawback is its invasiveness. Blood loss, radiation exposure, hospital stay, and morbidities of PNL can be significantly reduced with RIRS technique.
Experimental animal studies of radon and cigarette smoke
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cross, F.T.; Dagle, G.E.; Gies, R.A.
Cigarette-smoking is a dominant cause of lung cancer and confounds risk assessment of exposure to radon decay products. Evidence in humans on the interaction between cigarette-smoking and exposure to radon decay products, although limited, indicates a possible synergy. Experimental animal data, in addition to showing synergy, also show a decrease or no change in risk with added cigarette-smoke exposures. This article reviews previous animal data developed at Compagnie Generale des Matieres Nucleaires and Pacific Northwest Laboratory (PNL) on mixed exposures to radon and cigarette smoke, and highlights new initiation-promotion-initiation (IPI) studies at PNL that were designed within the framework ofmore » a two-mutation carcinogenesis model. Also presented are the PNL exposure system, experimental protocols, dosimetry, and biological data observed to date in IPI animals.« less
Percutaneous nephrolithotomy for complete staghorn renal stones.
Koko, Abdelmoniem H; Onuora, Vincent C; Al-Turkey, Mohamamed A; Al Moss, Mohammed; Meabed, Ahmed H; Al Jawani, Nasser A
2007-03-01
To evaluate the effectiveness of percutaneous nephrolithotomy (PNL) in the management of patients with complete staghorn stones, a retrospective study was conducted on 110 patients at the Riyadh Medical Complex, Riyadh, Kingdom of Saudi Arabia. The study was performed between September 1990 and September 1999. 144 procedures were performed on 119 renal units including 22 units (18.5%) that needed more than one sitting. Of them, 85 units (71.4%) were completely cleared after PNL and 11 units (9.2%) were left with insignificant residual fragments (< 4 mm). This gives a success rate of 78.6% for PNL as a monotherapy. Twelve patients with significant residual fragments required Extracorporal Shock Wave Lithotripsy (SWL) in addition to PNL. The overall success rate after PNL and SWL in 108 renal units was 89.4%. We found PNL useful in the management of patients with complete staghorn stones, either as monotherapy or in combination with SWL. It was associated with little morbidity and the procedure can be instituted even in centers with limited facilities.
Review of technologies for the pretreatment of retrieved single-shell tank waste at Hanford
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gerber, M.A.
1992-08-01
The purpose of the study reported here was to identify and evaluate innovative processes that could be used to pretreat mixed waste retrieved from the 149 single-shell tanks (SSTs) on the US Department of Energy's (DOE) Hanford site. The information was collected as part of the Single Shell Tank Waste Treatment project at Pacific Northwest Laboratory (PNL). The project is being conducted for Westinghouse Hanford Company under their SST Disposal Program.
Review of technologies for the pretreatment of retrieved single-shell tank waste at Hanford
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gerber, M.A.
1992-08-01
The purpose of the study reported here was to identify and evaluate innovative processes that could be used to pretreat mixed waste retrieved from the 149 single-shell tanks (SSTs) on the US Department of Energy`s (DOE) Hanford site. The information was collected as part of the Single Shell Tank Waste Treatment project at Pacific Northwest Laboratory (PNL). The project is being conducted for Westinghouse Hanford Company under their SST Disposal Program.
Poyraz, Necdet; Balasar, Mehmet; Gökmen, İbrahim Erdem; Koç, Osman; Sönmez, Mehmet Giray; Aydın, Arif; Göger, Yunus Emre; Öztürk, Ahmet
2017-12-01
Percutaneous nephrolithotomy (PNL) is the preferred procedure for safe and effective surgical treatment of kidney stones. Hemorrhage is the most serious complication of PNL, resulting from pseudoaneurysm (PA) or arteriovenous fistula (AVF), and can usually be controlled with conservative treatment. To evaluate endovascular treatments and outcomes of vascular complications observed after PNL. We retrospectively reviewed data on 19 patients who underwent renal embolization due to post-PNL renal artery bleeding between March 2005 and September 2016. Embolization materials included embolization coils and glue. The incidence of post-PNL vascular complications and their endovascular treatments, outcomes, and the follow-up data were analyzed. Nineteen (1.1%) of 1,609 patients (mean age: 44.9 years, range: 19-75 years) underwent angiography and subsequent transcatheter embolization to control bleeding. The mean time to onset of hemorrhage was 7.2 days after PNL (range: 3-18 days). The PNL entry site was the lower calyx in 15 patients, the middle calyx in 3, and the upper calyx in 1. PA, AVF, and PA plus AVF occurred in 14, 5, and 3 of the 19 renal angiography patients, respectively. Embolization of the affected vessels was successful in all 19 patients. The embolization materials of coil, glue, and coil plus glue were used in 16, 3, and 2 patients, respectively. Severe hematuria is a rare complication of PNL and can be successfully treated with transcatheter embolization.
Srivastava, A; Gupta, P; Chaturvedi, S; Singh, P; Kapoor, R; Dubey, D; Kumar, A
2010-01-01
To assess the feasibility, safety and results of percutaneous nephrolithotomy (PNL) in ectopically located kidneys and in patients with musculoskeletal deformities. Thirteen such patients underwent PNL between June 2005 and May 2008. Mean stone size was 27.4 mm (16-37 mm). Six patients had severe kyphoscoliosis, 2 patients each had achondroplasia, cross-fused ectopia and pelvic ectopic kidney, and 1 patient had thoracic kidney. All had a preoperative CT scan of the abdomen. Preoperative ultrasound- or CT-guided percutaneous nephrostomy (PCN) was done in 10 patients. Three patients underwent laparoscopic-assisted PNL. All underwent standard PNL. The stone-free rate, complication rate and need for secondary intervention were evaluated. PNL was successfully completed in all. A second ultrasound-guided intraoperative puncture was required in 2 patients. Re-look PNL was required in 1 patient and the same patient later required shock wave lithotripsy for complete stone clearance. The remaining 12 patients (92.3%) were rendered stone-free in a single sitting. PNL is a feasible and effective modality in anomalous kidneys. Preoperative planning with CT and image-guided PCN is helpful in these situations. Laparoscopic-assisted PNL can be safely performed in patients where access to a renal collecting system by fluoroscopy or image-guided assistance (ultrasound or CT scan) is not possible. Copyright (c) 2010 S. Karger AG, Basel.
[Ultrasound guided percutaneous nephrolithotripsy].
Guliev, B G
2014-01-01
The study was aimed to the evaluation of the effectiveness and results of ultrasound guided percutaneous nephrolithotripsy (PNL) for the treatment of patients with large stones in renal pelvis. The results of PNL in 138 patients who underwent surgery for kidney stones from 2011 to 2013 were analyzed. Seventy patients (Group 1) underwent surgery with combined ultrasound and radiological guidance, and 68 patients (Group 2)--only with ultrasound guidance. The study included patients with large renal pelvic stones larger than 2.2 cm, requiring the formation of a single laparoscopic approach. Using the comparative analysis, the timing of surgery, the number of intra- and postoperative complications, blood loss and length of stay were evaluated. Percutaneous access was successfully performed in all patients. Postoperative complications (exacerbation of chronic pyelonephritis, gross hematuria) were observed in 14.3% of patients in Group 1 and in 14.7% of patients in Group 2. Bleeding requiring blood transfusion, and injuries of adjacent organs were not registered. Efficacy of PNL in the Group 1 was 95.7%; 3 (4.3%) patients required additional interventions. In Group 2, the effectiveness of PNL was 94.1%, 4 (5.9%) patients additionally underwent extracorporeal lithotripsy. There were no significant differences in the effectiveness of PNL, the volume of blood loss and duration of hospitalization. Ultrasound guided PNL can be performed in large pelvic stones and sufficient expansion of renal cavities, thus reducing radiation exposure of patients and medical staff.
Ozgor, Faruk; Kucuktopcu, Onur; Sarılar, Omer; Toptas, Mehmet; Simsek, Abdulmuttalip; Gurbuz, Zafer Gokhan; Akbulut, Mehmet Fatih; Muslumanoglu, Ahmet Yaser; Binbay, Murat
2015-11-01
In this study, we aim to evaluate the effectiveness and safety of PNL in patients with a history of open renal surgery or PNL by comparing with primary patients and to compare impact of previous open renal surgery and PNL on the success and complications of subsequent PNL. Charts of patients, who underwent PNL at our institute, were analyzed retrospectively. Patients were divided into three groups according to history of renal stone surgery. Patients without history of renal surgery were enrolled into Group 1. Other patients with previous PNL and previous open surgery were categorized as Group 2 and Group 3. Preoperative characteristic, perioperative data, stone-free status, and complication rates were compared between the groups. Stone-free status was accepted as completing clearance of stone and residual fragment smaller than 4 mm. Eventually, 2070 patients were enrolled into the study. Open renal surgery and PNL had been done in 410 (Group 2) and 131 (Group 3) patients, retrospectively. The mean operation time was longer (71.3 ± 33.5 min) in Group 2 and the mean fluoroscopy time was longer (8.6 ± 5.0) in Group 3 but there was no statistically significant difference between the groups. Highest stone clearance was achieved in primary PNL patients (81.62%) compared to the other groups (77.10% in Group 2 and 75.61% in Group 3). Stone-free rate was not significantly different between Group 2 and Group 3. Fever, pulmonary complications, and blood transfusion requirement were not statically different between groups but angioembolization was significantly higher in Group 2. Percutaneous nephrolithotomy is a safe and effective treatment modality for patients with renal stones regardless history of previous PNL or open renal surgery. However, history of open renal surgery but not PNL significantly reduced PNL success.
Hui, Monalisa; Uppin, Megha S.; Challa, Sundaram; Meena, A. K.; Kaul, Subhash
2015-01-01
Background and Purpose: Demonstration of lepra bacilli is essential for definite or unequivocal diagnosis of pure neuritic leprosy (PNL) on nerve biopsy. However, nerves always do not show bacilli owing to the changes of previous therapy or due to low bacillary load in tuberculoid forms. In absence of granuloma or lepra bacilli, other morphologic changes in endoneurium and perineurium can be of help in making a probable diagnosis of PNL and treating the patient with multidrug therapy. Materials and Methods: Forty-six biopsies of PNL were retrospectively reviewed and histologic findings were compared with 25 biopsies of non leprosy neuropathies (NLN) including vasculitic neuropathy and chronic inflammatory demyelinating polyneuropathy (CIDP). The distribution of endoneurial infiltrate and fibrosis, perineurial thickening, and myelin abnormalities were compared between PNL and NLN biopsies and analyzed by Chi-square test. Results: Out of 46 PNL casses, 24 (52.17 %) biopsies were negative for acid fast bacilli (AFB). In these cases, the features which favor a diagnosis of AFB-negative PNL were endoneurial infiltrate (51.1%), endoneurial fibrosis (54.2%), perineurial thickening (70.8%), and reduced number of myelinated nerve fibers (75%). Interpretation and Conclusion: Nerve biopsy is an efficient tool to diagnose PNL and differentiate it from other causes of NLN. In absence of AFB, the diagnosis of PNL is challenging. In this article, we have satisfactorily evaluated the various hisopthological features and found that endoneurial inflammation, dense fibrosis, and reduction in the number of myelinated nerve fibers are strong supportive indicators of PNL regardless of AFB positivity. PMID:26425006
Hui, Monalisa; Uppin, Megha S; Challa, Sundaram; Meena, A K; Kaul, Subhash
2015-01-01
Demonstration of lepra bacilli is essential for definite or unequivocal diagnosis of pure neuritic leprosy (PNL) on nerve biopsy. However, nerves always do not show bacilli owing to the changes of previous therapy or due to low bacillary load in tuberculoid forms. In absence of granuloma or lepra bacilli, other morphologic changes in endoneurium and perineurium can be of help in making a probable diagnosis of PNL and treating the patient with multidrug therapy. Forty-six biopsies of PNL were retrospectively reviewed and histologic findings were compared with 25 biopsies of non leprosy neuropathies (NLN) including vasculitic neuropathy and chronic inflammatory demyelinating polyneuropathy (CIDP). The distribution of endoneurial infiltrate and fibrosis, perineurial thickening, and myelin abnormalities were compared between PNL and NLN biopsies and analyzed by Chi-square test. Out of 46 PNL casses, 24 (52.17 %) biopsies were negative for acid fast bacilli (AFB). In these cases, the features which favor a diagnosis of AFB-negative PNL were endoneurial infiltrate (51.1%), endoneurial fibrosis (54.2%), perineurial thickening (70.8%), and reduced number of myelinated nerve fibers (75%). Nerve biopsy is an efficient tool to diagnose PNL and differentiate it from other causes of NLN. In absence of AFB, the diagnosis of PNL is challenging. In this article, we have satisfactorily evaluated the various hisopthological features and found that endoneurial inflammation, dense fibrosis, and reduction in the number of myelinated nerve fibers are strong supportive indicators of PNL regardless of AFB positivity.
Sari, Sercan; Ozok, Hakki Ugur; Cakici, Mehmet Caglar; Ozdemir, Harun; Bas, Okan; Karakoyunlu, Nihat; Sagnak, Levent; Senturk, Aykut Bugra; Ersoy, Hamit
2017-01-18
In this retrospective study, we aimed to compare the outcomes in patients who have been treated withpercutaneous nephrolithotomy (PNL) and retrograde intrarenal surgery (RIRS) on renal stones ≥ 2 cm size. We evaluated patients who underwent PNL or RIRS for renal stones ≥ 2 cm size betweenNovember 2011 and November 2014. Stone size, operation, fluoroscopy and hospitalization time, success rates,stone-free rates and complication rates were compared in both groups. Patients were followed for three months. 254 patients were in the PNL Group. 185 patients were in the RIRS Group. The mean age was 46.88 and48.04 years in PNL and RIRS groups, respectively.The patient and stone characteristics (age, gender, Body Mass Index, kidney anomaly, SWL history and stoneradioopacity) were similar between two groups.The mean stone size preoperatively was significantly larger in patients who were treated with PNL (26.33mm.vs24.04mm.; P = .006). In the RIRS group, the mean stone number was significantly higher than PNL group (P <.001).The mean operative, fluoroscopy and hospitalization time were significantly higher in PNL group (P < .001). Thestone-free rate was 93.3% for the PNL group and 73.5% for the RIRS group after first procedure (P < .001). Nomajor complication (Clavien III-V) occurred in the RIRS group. Although the primary treatment method for renal stones ≥ 2cm size is PNL, serious complicationscan be seen. Therefore, RIRS can be an alternative treatment option in the management of renal stones ≥2 cm size.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morris, F. A.; Sawyer, C. H.; Maxwell, J. H.
1979-10-01
The Regional Assessments Division in the US Department of Energy (DOE) has undertaken a program to assess the probable consequences of various national energy policies in regions of the United States and to evaluate the constraints on national energy policy imposed by conditions in these regions. The program is referred to as the Regional Issues Identification and Assessment (RIIA) Program. Currently the RIIA Program is evaluating the Trendlong Mid-Mid scenario, a pattern of energy development for 1985 and 1990 derived from the Project Independence Evaluation System (PIES) model. This scenario assumes a medium annual growth rate in both the nationalmore » demand for and national supply of energy. It has been disaggregated to specify the generating capacity to be supplied by each energy source in each state. Pacific Northwest Laboratory (PNL) has the responsibility for evaluating the scenario for the Federal Region 10, consisting of Alaska, Idaho, Oregon, and Washington. PNL is identifying impacts and constraints associated with realizing the scenario in a variety of categories, including air and water quality impacts, health and safety effects, and socioeconomic impacts. This report summarizes the analysis of one such category: institutional constraints - defined to include legal, organizational, and political barriers to the achievement of the scenario in the Northwest.« less
Percutaneous nephrolithotomy in children: A preliminary report
Elderwy, Ahmad A.; Gadelmoula, Mohamed; Elgammal, Mohamed A.; Osama, Ehab; Al-Hazmi, Hamdan; Hammouda, H.; Osman, Esam; Abdullah, Medhat A.; Neel, Khalid Fouda
2014-01-01
Objectives: The recurrence of pediatric nephrolithiasis, the morbidity of repeated open surgical treatment as well as our experience in percutaneous nephrolithotomy (PNL) in adult patients, all derived us to shift to PNL for managing renal stones >1.5 cm in pediatric patients. Our aim of this study is to evaluate the safety and efficacy of PNL in pediatric patients. Materials and Methods: During the period of the month between May 2011 and April 2013, 38 children (47 renal units) underwent PNL for renal stones 1.5-5 cm in length. Patient demographics, stone characteristics, and clinical outcome were prospectively studied. Data of those who underwent conventional and tubeless PNL were compared. Median follow-up period was 12 months (range: 6-24). Results: The median age at presentation was 8-year (range: 3-12). The operative time ranged from 30 to 120 min (median 90). Overall stone clearance rate was 91.5% after single PNL. The median hospital stay was 3 days. Auxiliary procedures were successful for the remaining 4 patients (nephroscopic clearance in one and shockwave lithotripsy in 3). Tubeless PNL was performed in 17 renal units with a comparable outcome to conventional ones. The perioperative complications were noted in 5/47 (10.6%) of all procedures (Clavien Grade II in 4 and Clavien Grade IIIa in 1) and were managed conservatively. Conclusions: Percutaneous nephrolithotomy for renal stones in pediatric patients is safe and feasible if performed by a well-experienced endourologist. Tubeless PNL is a better choice for children. PMID:25125889
Percutaneous nephrolithotomy in children: A preliminary report.
Elderwy, Ahmad A; Gadelmoula, Mohamed; Elgammal, Mohamed A; Osama, Ehab; Al-Hazmi, Hamdan; Hammouda, H; Osman, Esam; Abdullah, Medhat A; Neel, Khalid Fouda
2014-07-01
The recurrence of pediatric nephrolithiasis, the morbidity of repeated open surgical treatment as well as our experience in percutaneous nephrolithotomy (PNL) in adult patients, all derived us to shift to PNL for managing renal stones >1.5 cm in pediatric patients. Our aim of this study is to evaluate the safety and efficacy of PNL in pediatric patients. During the period of the month between May 2011 and April 2013, 38 children (47 renal units) underwent PNL for renal stones 1.5-5 cm in length. Patient demographics, stone characteristics, and clinical outcome were prospectively studied. Data of those who underwent conventional and tubeless PNL were compared. Median follow-up period was 12 months (range: 6-24). The median age at presentation was 8-year (range: 3-12). The operative time ranged from 30 to 120 min (median 90). Overall stone clearance rate was 91.5% after single PNL. The median hospital stay was 3 days. Auxiliary procedures were successful for the remaining 4 patients (nephroscopic clearance in one and shockwave lithotripsy in 3). Tubeless PNL was performed in 17 renal units with a comparable outcome to conventional ones. The perioperative complications were noted in 5/47 (10.6%) of all procedures (Clavien Grade II in 4 and Clavien Grade IIIa in 1) and were managed conservatively. Percutaneous nephrolithotomy for renal stones in pediatric patients is safe and feasible if performed by a well-experienced endourologist. Tubeless PNL is a better choice for children.
Chung, Ho Seok; Jung, Seung Il; Yu, Ho Song; Hwang, Eu Chang; Oh, Kyung Jin; Kwon, Dong Deuk; Park, Kwangsung
2016-01-01
We hypothesized that modified totally tubeless percutaneous nephrolithotomy (PNL) without indwelling ureteral stent would minimize postoperative discomfort without complications. To evaluate the safety, efficacy, and morbidity of standard, tubeless, and modified totally tubeless PNL as well as the usefulness of modified totally tubeless PNL. From November 2011 to February 2015, 211 patients who underwent PNL consecutively were enrolled in this study and divided into 3 groups (group 1: standard, group 2: tubeless, group 3: modified totally tubeless PNL). Patient and stone characteristics, operation time, hemoglobin change, length of hospitalization, stone-free rate, analgesic requirement, and perioperative complications were analyzed and compared among the 3 groups. There were no significant differences in preoperative patient characteristics among the three groups. In the postoperative analysis, the three groups had similar operation time, stone-free rate, perioperative fever and transfusion rate, but group 2 showed superior results in terms of length of hospitalization (p = 0.001). Group 2 and group 3 had a lower analgesic requirement (p = 0.010). Immediate postoperative hemoglobin change (p = 0.001) and tube site complications (p = 0.001) were more common in group 1. Modified totally tubeless PNL was not inferior in terms of postoperative outcomes and safety compared with the standard and tubeless PNL, and avoided the postoperative stent-related symptoms and cystoscopy for double-J stent removal. Modified totally tubeless PNL could be an alternative treatment of choice for management of renal or upper ureteral stones in selected patients.
Poyraz, Necdet; Balasar, Mehmet; Gökmen, İbrahim Erdem; Koç, Osman; Aydın, Arif; Göger, Yunus Emre; Öztürk, Ahmet
2017-01-01
Introduction Percutaneous nephrolithotomy (PNL) is the preferred procedure for safe and effective surgical treatment of kidney stones. Hemorrhage is the most serious complication of PNL, resulting from pseudoaneurysm (PA) or arteriovenous fistula (AVF), and can usually be controlled with conservative treatment. Aim To evaluate endovascular treatments and outcomes of vascular complications observed after PNL. Material and methods We retrospectively reviewed data on 19 patients who underwent renal embolization due to post-PNL renal artery bleeding between March 2005 and September 2016. Embolization materials included embolization coils and glue. The incidence of post-PNL vascular complications and their endovascular treatments, outcomes, and the follow-up data were analyzed. Results Nineteen (1.1%) of 1,609 patients (mean age: 44.9 years, range: 19–75 years) underwent angiography and subsequent transcatheter embolization to control bleeding. The mean time to onset of hemorrhage was 7.2 days after PNL (range: 3–18 days). The PNL entry site was the lower calyx in 15 patients, the middle calyx in 3, and the upper calyx in 1. PA, AVF, and PA plus AVF occurred in 14, 5, and 3 of the 19 renal angiography patients, respectively. Embolization of the affected vessels was successful in all 19 patients. The embolization materials of coil, glue, and coil plus glue were used in 16, 3, and 2 patients, respectively. Conclusions Severe hematuria is a rare complication of PNL and can be successfully treated with transcatheter embolization. PMID:29362656
Toxicologic evaluation of analytes from Tank 241-C-103
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mahlum, D.D.; Young, J.Y.; Weller, R.E.
1994-11-01
Westinghouse Hanford Company requested PNL to assemble a toxicology review panel (TRP) to evaluate analytical data compiled by WHC, and provide advice concerning potential health effects associated with exposure to tank-vapor constituents. The team`s objectives would be to (1) review procedures used for sampling vapors from tanks, (2) identify constituents in tank-vapor samples that could be related to symptoms reported by workers, (3) evaluate the toxicological implications of those constituents by comparison to establish toxicological databases, (4) provide advice for additional analytical efforts, and (5) support other activities as requested by WHC. The TRP represents a wide range of expertise,more » including toxicology, industrial hygiene, and occupational medicine. The TRP prepared a list of target analytes that chemists at the Oregon Graduate Institute/Sandia (OGI), Oak Ridge National Laboratory (ORNL), and PNL used to establish validated methods for quantitative analysis of head-space vapors from Tank 241-C-103. this list was used by the analytical laboratories to develop appropriate analytical methods for samples from Tank 241-C-103. Target compounds on the list included acetone, acetonitrile, ammonia, benzene, 1, 3-butadiene, butanal, n-butanol, hexane, 2-hexanone, methylene chloride, nitric oxide, nitrogen dioxide, nitrous oxide, dodecane, tridecane, propane nitrile, sulfur oxide, tributyl phosphate, and vinylidene chloride. The TRP considered constituent concentrations, current exposure limits, reliability of data relative to toxicity, consistency of the analytical data, and whether the material was carcinogenic or teratogenic. A final consideration in the analyte selection process was to include representative chemicals for each class of compounds found.« less
Sen, Haluk; Seckiner, Ilker; Bayrak, Omer; Erturhan, Sakip; Demirbağ, Asaf
2015-02-01
The treatment of stone disease is mostly similar in those adult and children. The standard treatment procedures are as follows: extracorporeal shock wave lithotripsy (ESWL), ureterorenoscopy (URS), percutaneous nephrolithotomy (PCNL), and laparoscopic surgery in selected cases. Open surgery (OS) is another option particularly in such cases with anatomic abnormalities of urinary tract. The present study aims to provide comparative results of stone removal procedures in preschool aged patients who were diagnosed with urinary system stone disease. The retrospective data of 616 pediatric preschool patients consulted with urinary system stone disease between January 2009 and July 2013 were evaluated. All patients were evaluated with Kidney-Ureter-Bladder (KUB) Xray and abdomino-pelvic ultrasound. Intravenous pyelography, unenhanced computed tomography (CT), and renal scintigraphy were performed when needed. Patients were categorized according to the procedures as: Group ESWL, Group URS, Group PNL, Group micro-PNL and Group OS. Following the procedures, opaque residual stones were evaluated with KUB Xray, and non-opaque residual stones were evaluated with unenhanced CT. In groups (ESWL, URS, PNL, micro-PNL, OS), the stone-free rate was 68%, 66%, 85%, 100% and 94 %, respectively. The stone analysis were observed as, calcium oxalate in 377 patients (61.2%), uric acid in 106 patients (17.2%), infection stone in 73 patients (11.8 %), and cysteine in 60 patients (9.7%). There was no significant difference in stone analysis between the groups (p > 0.05) (Table). Minimally invasive procedures are frequently preferred in the pediatric age urinary system stone disease. These procedures are ESWL, PCNL, and ureteroscopy [10,11]. Open surgery is reserved only for rare cases [12]. Similarly the current literature, 18 (2.9%) patients had anatomical anomaly and had high complex stone burden were treated with open surgery in our study. ESWL is a preferred treatment method for pediatric urolithiasis patients with a stone size <20 mm, and the rate of stone-free after ESWL ranges between 57 and 92% [13]. In a study showed the effect of stone size on the success rate in ESWL, the success rate was 91% for stones <10 mm, and 75% for stones >10 mm [15]. In the present study, stone-free rate was noted as 68% on 15 mm or lower stone size. PNL is commonly used to treat stone disease in preschool children [18-20]. In the beginning, urologists hesitated to use instruments suited for adults in case of pediatric kidneys. While some authors accept a cut-off value of 24 F for tract dilatation in the pediatric age, Desai et al. recommended a threshold value <22 F [19,21]. In our study, we used adult PNL instruments in the early period, whereas mini-PERC was performed in the later years. The success rate in PNL group was found as 85%. In recent years, the micro-PNL procedure has been developed to reduce/prevent the complications of standard PNL. In our study, the success rate was calculated as 100% with micro-PNL. This study has certain limitations. The major limitation of our study is its retrospective nature. In addition, sample size of micro-PNL group is fewer than other groups. The goal of kidney stone treatment is to achieve minimal kidney damage and a high success rate. Thus, the procedures are important in the pediatric age group where life expectancy is high, and particularly in the preschool age group. Copyright © 2015 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gillespie, B.M.; Stromatt, R.W.; Ross, G.A.
This data package contains the results obtained by Pacific Northwest Laboratory (PNL) staff in the characterization of samples for the 101-SY Hydrogen Safety Project. The samples were submitted for analysis by Westinghouse Hanford Company (WHC) under the Technical Project Plan (TPP) 17667 and the Quality Assurance Plan MCS-027. They came from a core taken during Window C'' after the May 1991 gas release event. The analytical procedures required for analysis were defined in the Test Instructions (TI) prepared by the PNL 101-SY Analytical Chemistry Laboratory (ACL) Project Management Office in accordance with the TPP and the QA Plan. The requestedmore » analysis for these samples was volatile organic analysis. The quality control (QC) requirements for each sample are defined in the Test Instructions for each sample. The QC requirements outlined in the procedures and requested in the WHC statement of work were followed.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gillespie, B.M.; Stromatt, R.W.; Ross, G.A.
This data package contains the results obtained by Pacific Northwest Laboratory (PNL) staff in the characterization of samples for the 101-SY Hydrogen Safety Project. The samples were submitted for analysis by Westinghouse Hanford Company (WHC) under the Technical Project Plan (TPP) 17667 and the Quality Assurance Plan MCS-027. They came from a core taken during Window ``C`` after the May 1991 gas release event. The analytical procedures required for analysis were defined in the Test Instructions (TI) prepared by the PNL 101-SY Analytical Chemistry Laboratory (ACL) Project Management Office in accordance with the TPP and the QA Plan. The requestedmore » analysis for these samples was volatile organic analysis. The quality control (QC) requirements for each sample are defined in the Test Instructions for each sample. The QC requirements outlined in the procedures and requested in the WHC statement of work were followed.« less
Chung, Ho Seok; Yu, Ho Song; Hwang, Eu Chang; Oh, Kyung Jin; Kwon, Dong Deuk; Park, Kwangsung
2016-01-01
Introduction We hypothesized that modified totally tubeless percutaneous nephrolithotomy (PNL) without indwelling ureteral stent would minimize postoperative discomfort without complications. Aim To evaluate the safety, efficacy, and morbidity of standard, tubeless, and modified totally tubeless PNL as well as the usefulness of modified totally tubeless PNL. Material and methods From November 2011 to February 2015, 211 patients who underwent PNL consecutively were enrolled in this study and divided into 3 groups (group 1: standard, group 2: tubeless, group 3: modified totally tubeless PNL). Patient and stone characteristics, operation time, hemoglobin change, length of hospitalization, stone-free rate, analgesic requirement, and perioperative complications were analyzed and compared among the 3 groups. Results There were no significant differences in preoperative patient characteristics among the three groups. In the postoperative analysis, the three groups had similar operation time, stone-free rate, perioperative fever and transfusion rate, but group 2 showed superior results in terms of length of hospitalization (p = 0.001). Group 2 and group 3 had a lower analgesic requirement (p = 0.010). Immediate postoperative hemoglobin change (p = 0.001) and tube site complications (p = 0.001) were more common in group 1. Conclusions Modified totally tubeless PNL was not inferior in terms of postoperative outcomes and safety compared with the standard and tubeless PNL, and avoided the postoperative stent-related symptoms and cystoscopy for double-J stent removal. Modified totally tubeless PNL could be an alternative treatment of choice for management of renal or upper ureteral stones in selected patients. PMID:28194243
Factors Influencing Complications of Percutaneous Nephrolithotomy: A Single-Center Study.
Oner, Sedat; Okumus, Muhammed Masuk; Demirbas, Murat; Onen, Efe; Aydos, Mustafa Murat; Ustun, Mehmet Hakan; Kilic, Metin; Avci, Sinan
2015-11-14
Percutaneous nephrolithotomy (PNL) is a minimally invasive procedure used for successful treatment of renal calculi. However, it is associated with various complications. We assessed the complications and their potential influencing factors in patients who had undergone PNL. In total, 1750 patients who had undergone PNL from November 2003 to June 2011 were evaluated retrospectively. PNL complications and possible contributing risk factors (age, sex, serum creatinine level, previous operations, hydronephrosis, calculi size, localization, opacity, surgeon's experience, accessed calyxes, number of accesses, and costal entries) were determined. Receiver operating characteristic (ROC) analysis was used to investigate the cutoff values of the data. Ideal cutoff value was determined by Youden's J statistic. All the demographic and clinical variables were examined using backward stepwise logistical regression analysis. Continuous variables were categorized with logistic regression analysis according to the cutoff values. Complications occurred in 396 (24.4%) patients who had undergone PNL. Hemorrhage requiring blood transfusion occurred in 221 (12.6%) patients, hemorrhage requiring arterial embolization occurred in 7 (0.4%) patients, perirenal hematoma occurred in 17 (0.97%) patients, hemo-pneumothorax occurred in 32 (1.8%) patients, and colon perforation occurred in 4 (0.22%) patients. Three patients (0.06%) died of severe urosepsis, and one patient (0.02%) died of severe bleeding. The calculus size, localization, access site, number of accesses, presence of staghorn stones, surgeon's experience, and duration of the operation significantly affected the complication risk. Our retrospective evaluation of this large patient series reveals that, PNL is a very effective treatment modality for kidney stones. However, although rare, serious complications including death can occur.
Akbulut, Fatih; Kucuktopcu, Onur; Kandemir, Emre; Sonmezay, Erkan; Simsek, Abdulmuttalip; Ozgor, Faruk; Binbay, Murat; Muslumanoglu, Ahmet Yaser; Gurbuz, Gokhan
2016-01-01
To compare the outcomes of flexible ureterorenoscopy (F-URS) and mini-percutaneous nephrolithotomy (mini-PNL) in the treatment of lower calyceal stones smaller than 2 cm. Patients who underwent F-URS and mini-PNL for the treatment of lower calyceal stones smaller than 2 cm between March 2009 and December 2014 were retrospectively evaluated. Ninety-four patients were divided into two groups by treatment modality: F-URS (Group 1: 63 patients) and mini-PNL (Group 2: 31 patients). All patients were preoperatively diagnosed with intravenous pyelography or computed tomography. Success rates for F-URS and mini-PNL at postoperative first month were 85.7% and 90.3%, respectively. Operation time, fluoroscopy time, and hospitalization time for F-URS and mini-PNL patients were 44.40 min, 2.9 min, 22.4 h, and 91.9 min, 6.4 min, and 63.8 h, respectively. All three parameters were significantly shorter among the F-URS group (p < 0.001). Postoperative hemoglobin drop was significantly lower in F-URS group compared to mini-PNL group (0.39 mg/dL vs. 1.15 mg/dL, p = 0.001). A comparison of complications according to the Clavien classification demonstrated significant differences between the groups (p = 0.001). More patients in the F-URS groups require antibiotics due to urinary tract infection, and more patients in the mini-PNL group required ureteral double J catheter insertion under general anesthesia. Although both F-URS and mini-PNL have similar success rates for the treatment of lower calyceal stones, F-URS appears to be more favorable due to shorter fluoroscopy and hospitalization times; and lower hemoglobin drops. Multicenter and studies using higher patient volumes are needed to confirm these findings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baalman, R.W.; Hays, I.D.
1981-02-01
Pacific Northwest Laboratory's (PNL) 1980 annual report to the DOE Assistant Secretary for Environment describes research in environment, health, and safety conducted during fiscal year 1980. Part 5 includes technology assessments for natural gas, enhanced oil recovery, oil shale, uranium mining, magnetic fusion energy, solar energy, uranium enrichment and industrial energy utilization; regional analysis studies of environmental transport and community impacts; environmental and safety engineering for LNG, oil spills, LPG, shale oil waste waters, geothermal liquid waste disposal, compressed air energy storage, and nuclear/fusion fuel cycles; operational and environmental safety studies of decommissioning, environmental monitoring, personnel dosimetry, and analysis ofmore » criticality safety; health physics studies; and epidemiological studies. Also included are an author index, organization of PNL charts and distribution lists of the annual report, along with lists of presentations and publications. (DLS)« less
Pacific Northwest Laboratory annual report for 1990 to the DOE Office of Energy Research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, J.F.
This report summarizes progress on OHER human health, biological, and general life sciences research programs conducted at PNL in FY 1990. The research develops the knowledge and scientific principles necessary to identify understand, and anticipate the long-term health consequences of energy-related radiation and chemicals. Our continuing emphasis is to decrease the uncertainty of health risk estimates from existing and developing energy-related technologies through an increased of understanding of how radiation and chemicals cause biological damage. The sequence of this report of PNL research reflects the OHER programmatic structure. The first section, on human health research, concerns epidemiological and statistical studiesmore » for assessing health risks. The next section contains reports of biological research in laboratory animals and in vitro cell systems, including research with radionuclides and chemicals. The general life sciences research section reports research conducted for the OHER human genome research program.« less
Mishra, Shashikant; Sharma, Rajan; Garg, Chandrapraksh; Kurien, Abraham; Sabnis, Ravindra; Desai, Mahesh
2011-09-01
• To evaluate the results of miniperc vis-à-vis standard PNL in the treatment of stones of 1-2 cm in size. Miniperc may represent a reasonable procedure in patients with nonbulky urolithiasis offering a similar outcome as standard percutaneous nephrolithotomy (PNL) with advantage of reduced morbidity. • 55 procedures including 27 miniperc and 28 standard PNL were performed for renal stones 1-2 cm in size. Pediatric patient, active urinary tract infection, renal malformation, uncorrected coagulopathy and morbid obesity patients were excluded from the study. • The parameters studied were demography, operative time, postoperative analgesic requirement, hemoglobin drop, complications and stone clearance. • Mean tract size was 18.2 ± 2 F (15-20) and 26.8 ± 2 F (24-30), P value <0.0001 in the miniperc and standard PNL, respectively. Holmium LASER and pneumatic lithotripter were the main energy sources used in miniperc and standard PNL, respectively. • Miniperc operative time was longer than that of standard PNL (45.2 ± 12.6 vs 31 ± 16.6 min, P= 0.0008 respectively). • Conversely, there was an advantage of miniperc over standard PNL in terms of a significantly reduced hemoglobin drop (0.8 ± 0.9 vs 1.3 ± 0.4 gram%, P= 0.01), analgesic requirement (55.4 ± 50 vs 70.2 ± 52 mg tramadol, P= 0.29) and hospital stay (3.2 ± 0.8 vs 4.8 ± 0.6 days, P ≤ 0.001), respectively. • Intra- operative conversion of the procedure into a tubeless PNL was significantly more in the miniperc group (P ≤ 0.001). The miniperc and standard PNL group had clearance rates of 96% and 100%, respectively at 1 month follow up. • This study demonstrated significant advantages of the miniperc procedure in terms of reduced bleeding leading to a tubeless procedure and reduced hospital stay. • The stone free rates and the complications were similar in either group. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Y.; Frank, J.R.; St. Martin, E.J.
Because of the chaotic nature of the corrosion process and the complexity of the electrochemical noise signals that are generated, there is no generally accepted method of measuring and interpreting these signals that allows the consistent detection and identification of sustained localized pitting (SLP) as compared to general corrosion. The authors have reexamined electrochemical noise analysis (ENA) of localized corrosion using different hardware, signal collection, and signal processing designs than those used in conventional ENA techniques. The new data acquisition system was designed to identify and monitor the progress of SLP by analyzing the power spectral density (PSD) of themore » trend of the corrosion current noise level (CNL) and potential noise level (PNL). Each CNL and PNL data point was calculated from the root-mean-square value of the ac components of current and potential fluctuation signals, which were measured simultaneously during a short time period. The PSD analysis results consistently demonstrated that the trends of PNL and CNL contain information that can be used to differentiate between SLP and general corrosion mechanisms. The degree of linear slope in the low-frequency portion of the PSD analysis was correlated with the SLP process. Laboratory metal coupons as well as commercial corrosion probes were tested to ensure the reproducibility and consistency of the results. The on-line monitoring capability of this new ENA method was evaluated in a bench-scale flow-loop system, which simulated microbially influenced corrosion (MIC) activity. The conditions in the test flow-loop system were controlled by the addition of microbes and different substrates to favor accelerated corrosion. The ENA results demonstrated that this in-situ corrosion monitoring system could effectively identify SLP corrosion associated with MIC, compared to a more uniform general corrosion mechanism. A reduction in SLP activity could be clearly detected by the ENA monitoring system when a corrosion inhibitor was added into one of the test loops during the corrosion testing.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Y. J.
Because of the chaotic nature of the corrosion process and the complexity of the electrochemical noise signals that are generated, there is no generally accepted method of measuring and interpreting these signals that allows the consistent detection and identification of sustained localized pitting (SLP) as compared to general corrosion. We have reexamined electrochemical noise analysis (ENA) of localized corrosion using different hardware, signal collection, and signal processing designs than those used in conventional ENA techniques. The new data acquisition system was designed to identify and monitor the progress of SLP by analyzing the power spectral density (PSD) of the trendmore » of the corrosion current noise level (CNL) and potential noise level (PNL). Each CNL and PNL data point was calculated from the root-mean- square value of the ac components of current and potential fluctuation signals, which were measured simultaneously during a short time period. The PSD analysis results consistently demonstrated that the trends of PNL and CNL contain information that can be used to differentiate between SLP and general corrosion mechanisms. The degree of linear slope in the low-frequency portion of the PSD analysis was correlated with the SLP process. Laboratory metal coupons as well as commercial corrosion probes were tested to ensure the reproducibility and consistency of the results. The on-line monitoring capability of this new ENA method was evaluated in a bench-scale flow-loop system, which simulated microbially influenced corrosion (MIC) activity. The conditions in the test flow-loop system were controlled by the addition of microbes and different substrates to favor accelerated corrosion. The ENA results demonstrated that this in-situ corrosion monitoring system could effectively identify SLP corrosion associated with MIC, compared to a more uniform general corrosion mechanism. A reduction in SLP activity could be clearly detected by the ENA monitoring system when a corrosion inhibitor was added into one of the test loops during the corrosion testing.« less
CURE: Clean use of reactor energy
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1990-05-01
This paper presents the results of a joint Westinghouse Hanford Company (Westinghouse Hanford)-Pacific Northwest Laboratory (PNL) study that considered the feasibility of treating radioactive waste before disposal to reduce the inventory of long-lived radionuclides, making the waste more suitable for geologic disposal. The treatment considered here is one in which waste would be chemically separated so that long-lived radionuclides can be treated using specific processes appropriate for the nuclide. The technical feasibility of enhancing repository performance by this type of treatment is considered in this report. A joint Westinghouse Hanford-PNL study group developed a concept called the Clean Use ofmore » Reactor Energy (CURE), and evaluated the potential of current technology to reduce the long-lived radionuclide content in waste from the nuclear power industry. The CURE process consists of three components: chemical separation of elements that have significant quantities of long-lived radioisotopes in the waste, exposure in a neutron flux to transmute the radioisotopes to stable nuclides, and packaging of radionuclides that cannot be transmuted easily for storage or geologic disposal. 76 refs., 32 figs., 24 tabs.« less
el-Nahas, Ahmed R; Eraky, Ibrahim; Shokeir, Ahmed A; Shoma, Ahmed M; el-Assmy, Ahmed M; el-Tabey, Nasr A; Soliman, Shady; Elshal, Ahmed M; el-Kappany, Hamdy A; el-Kenawy, Mahmoud R
2012-06-01
To determine factors affecting the stone-free rate and complications of percutaneous nephrolithotomy (PNL) for treatment of staghorn stones. The computerized database of patients who underwent PNL for treatment of staghorn stones between January 2003 and January 2011 was reviewed. All perioperative complications were recorded and classified according to modified Clavien classification system. The stone-free rate was evaluated with low-dose noncontrast computed tomography (CT). Univariate and multivariate statistical analyses were performed to determine factors affecting stone-free and complication rates. The study included 241 patients (125 male and 116 female) with a mean age of 48.7 ±14.3 years. All patients underwent 251 PNL (10 patients had bilateral stones). The stone-free rate of PNL monotherapy was 56% (142 procedures). At 3 months, the stone-free rate increased to 73% (183 kidneys) after shock wave lithotripsy. Independent risk factors for residual stones were complete staghorn stone and presence of secondary calyceal stones (relative risks were 2.2 and 3.1, respectively). The complication rate was 27% (68 PNL). Independent risk factors for development of complications were performance of the procedure by urologists other than experienced endourologist and positive preoperative urine culture (relative risks were 2.2 and 2.1, respectively). Factors affecting the incidence of residual stones after PNL are complete staghorn stones and the presence of secondary calyceal stones. Complications are significantly high if PNL is not performed by an experienced endourologist or if preoperative urine culture is positive. Copyright © 2012 Elsevier Inc. All rights reserved.
Acute kidney injury after percutaneous nephrolithotomy for stones in solitary kidneys.
El-Nahas, Ahmed R; Taha, Diaa-Eldin; Ali, Hussien M; Elshal, Ahmed M; Zahran, Mohamed H; El-Tabey, Nasr A; El-Assmy, Ahmed M; Harraz, Ahmed M; Moawad, Hazem E; Othman, Mahmoud M
2017-04-01
The aim of this study was to report the incidence, severity, outcome and risk factors of acute kidney injury (AKI) following percutaneous nephrolithotomy (PNL) in solitary kidneys. The study included consecutive adult patients who underwent PNL for treatment of calculi in a solitary kidney between May 2012 and July 2015. Patients with congenital renal anomalies or with stages 4 and 5 chronic kidney disease (CKD) were excluded. Serum creatinine levels were measured the day before PNL, daily after PNL for 2-5 days and after 3 months. AKI was depicted according to changes in early postoperative serum creatinine levels and its severity was determined based on the Acute Kidney Injury Network (AKIN) classification. The outcome of AKI was evaluated after 3 months by changes in the stage of CKD. Univariate and multivariate statistical analyses were conducted to determine risk factors for developing AKI. The study included 100 patients (62 males) with a mean ± SD age of 50 ± 11.7 years. Complications were reported for 27 patients. AKI developed in 25 patients; at the 3 month follow-up, 23 of them (92%) had completely recovered from AKI and two (8%) had developed stage 4 CKD. Independent risk factors for developing AKI were multiple PNL tracts and postoperative ureteric obstruction (relative risks were 14 and 22, respectively). The incidence of AKI was 25% after PNL for a solitary kidney. The likelihood of renal function recovery was 92%. Multiple PNL tracts and postoperative ureteric obstruction were risk factors for developing AKI.
Fort Stewart integrated resource assessment. Volume 1, Executive summary
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larson, L.L.; Keller, J.M.
1993-10-01
The US Department of Energy (DOE) Federal Energy Management Program (FEMP), supported by the Pacific Northwest Laboratory (PNL), has developed a model program that provides a systematic approach to evaluating energy opportunities that (1) identifies the building groups and end uses that use the most energy (not just have the greatest energy-use intensity), and (2) evaluates the numerous options for retrofit or installation of new technology that will result in the selection of the most cost-effective technologies. In essence, this model program provides the federal energy manager with a roadmap to significantly reduce energy use in a planned, rational, cost-effectivemore » fashion that is not biased by the constraints of the typical funding sources available to federal sites. The results from this assessment process can easily be turned into a five- to ten-year energy management plan that identifies where to start and how to proceed in order to reach the mandated energy consumption targets. This report provides the results of the fossil fuel and electric energy resource opportunity (ERO) assessments performed by PNL at the US Army US Forces Command (FORSCOM) Fort Stewart facility located approximately 25 miles southwest of Savannah, Georgia. It is a companion report to Volume 2, Baseline Detail, and Volume 3, Resource Assessment.« less
Yu, L P; Xu, T
2017-08-18
To evaluate the development, safety and efficacy of percutaneous nephrolithotomy(PNL) for management of upper urinary tract calculi in pediatric patients. In the study, 77 pediatric patients undergoing 87 PNLs through mini or standard tract for upper urinary tract calculi between January 2005 and December 2016 in Peking University People's hospital were reviewed, including 69 renal calculi, 6 upper ureteral calculi, 12 renal and upper ureteral calculi, 35 single calculi, 43 multiple calculi and 9 staghorn calculi. The development and efficacy of PNL in pediatric patients were studied by analyzing the characteristics and clinical indexes, and by reviewing the associated literature. The Clavien classification system was used to evaluate the complications after PNL. A total of 87 PNLs were performed in 77 pediatric patients. Eighty-one upper urinary tract calculi were managed through a single tract(93.1%), 5 pediatric patients were managed through 2 tracts(5.7%), and 1 pediatric patient was managed through 3 tracts(1.2%). The mean operating time was (77.0±29.8) min. The stone-free rate after one session was 100% for single calculi and 71.2% for multiple or staghorn calculi, 5(5.8%) children underwent auxiliary procedure to remove the residual calculi and the final stone-free rate of PNL was 88.5%. One of the main complications of pediatric PNL was fever. Sixteen (18.4%) had moderate fever(38-39 °C), 5 (5.7%) had high fever (39-40 °C) and there were no severe complications of infection, such as sepsis or septic shock. The mean hemoglobin loss was (10.3±16.1) g/L and the serum creatinine rise was (7.0±13.3) μmol/L. One(1.2%) pediatric patient suffered ureteroscopic lithotripsy because of the obstruction by the residual stone in ureter. No injury of organs or retroperitoneal urinary extravasation occurred. General assessment of the complications showed Clavien grade I complications in 14 (16.1%) pediatric patients, grade II in 7(8.0%) children and grade III in 1(1.2%) children. There was no grade IV or V complications. The overall complication rate was 25.3%. PNL for management of upper urinary tract calculi in pediatric patients is effective. Complications after PNL, as assessed with Clavien classification system, are mild and PNL in pediatric patients is safe.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Drucker, H.
1983-02-01
Biomedical and health effects research conducted at PNL in 1982 on the evaluation of risk to man from existing and/or developing energy-related technologies are described. Most of the studies described in this report relate to activities for three major energy technologies: nuclear fuel cycle; fossil fuel cycle (oil, gas, and coal process technologies, mining, and utilization; synfuel development), and fudion (biomagnetic effects). The report is organized under these technologies. In addition, research reports are included on the application of nuclear energy to biomedical problems. Individual projects are indexed separately.
Valuation of damages to recreational trout fishing in the Upper Northeast due to acidic deposition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Englin, J.E.; Cameron, T.A.; Mendelsohn, R.E.
1991-04-01
This report documents methods used to estimate economic models of changes in recreational fishing due to the acidic deposition. The analysis was conducted by Pacific Northwest Laboratory (PNL) and its subcontractors for the US Environmental Protection Agency (EPA) and the US Department of Energy (DOE) in support of the National Acidic Precipitation Assessment Program (NAPAP). The primary data needed to estimate these models were collected in the 1989 Aquatic Based Recreation Survey (ABRS), which was jointly funded by the DOE and the EPA's Office of Policy Planning and Evaluation. 11 refs., 5 figs., 15 tabs.
Aung, Phyu Phyu; Sarlomo-Rikala, Maarit; Lasota, Jerzy; Lai, Jin-Ping; Wang, Zeng-Feng; Miettinen, Markku
2012-02-01
Identification of metastatic melanoma can be difficult because of its considerable morphologic variation and mimicry of a wide variety of other tumors. The more melanoma-specific melanoma markers, MelanA/MART-1, HMB45, and tyrosinase, used in addition to S100 protein, all have limitations in sensitivity and specificity. In this study, we evaluated 2 new melanoma markers, monoclonal antibodies KBA62 and PNL2 to yet unidentified antigens, using a large panel of metastatic melanomas (n=214), desmoplastic melanomas (n=34), gastrointestinal mucosal melanomas (n=54), benign nevi (n=27), clear cell sarcomas (n=16), and nonmelanocytic tumors (n=1218). Immunoreactivity for KBA62 and PNL2 was found in all pigmented nevi and in 86% and 90% of metastatic melanomas, respectively. Mucosal melanomas showed a similar rate of PNL2 immunoreactivity but somewhat less frequent KBA62 positivity (72%). In addition, KBA62 was found to be a sensitive diagnostic marker for desmoplastic melanoma (28 of 34; 82%), whereas PNL2 was only rarely positive (2 of 34; 6%). KBA62-positive normal tissues included pericytes, vascular and parenchymal smooth muscles, and basal cells of complex epithelia, including myoepithelia, whereas PNL2 labeled only melanocytes and neutrophils. Among nonmelanocytic tumors, those that were KBA62 positive were nodular fasciitis, leiomyoma and leiomyosarcoma, gastrointestinal stromal tumors, benign and malignant nerve sheath tumors, synovial sarcoma, and subsets of various carcinomas, especially those with squamous cell/stratified epithelial differentiation. PNL2 positivity in nonmelanocytic tumors was more restricted but occurred consistently in angiomyolipoma and other perivascular epitheloid cell tumor and in chronic myeloid leukemia tissue infiltrates. KBA62 may assist in the identification of desmoplastic melanomas, but its widespread occurrence in nonmelanomas limits utility. PNL2 is highly specific for melanomas but lacks reactivity with desmoplastic melanomas. It is also an excellent supplementary marker for perivascular epitheloid cell tumor at various sites.
Aydemir, Hüseyin; Budak, Salih; Kumsar, Şükrü; Köse, Osman; Sağlam, Hasan Salih; Adsan, Öztuğ
2014-09-01
In this study, we aimed to evaluate, the efficacy of surgical methods and the factors affecting the residual stone rate by scrutinizing retrospectively the patients who had undergone renal stone surgery. Records of 109 cases of kidney stones who had been surgically treated between January 2010, and July 2013 were reviewed. Patients were divided into three groups in terms of surgical treatment; open stone surgery, percutaneous nephrolithotomy (PNL) and retrograde intrarenal surgery (RIRS). Patients' history, physical examination, biochemical and radiological images and operative and postoperative data were recorded. The patients had undergone PNL (n=74; 67.9%), RIRS (n=22;20.2%), and open renal surgery (n=13; 11.9%). The mean and median ages of the patients were 46±9, 41 (21-75) and, 42 (23-67) years, respectively. The mean stone burden was 2.6±0.7 cm(2) in the PNL, 1.4±0.1 cm(2) in the RIRS, and 3.1±0.9 cm(2) in the open surgery groups. The mean operative times were 126±24 min in the PNL group, 72±12 min in the RIRS group and 82±22 min in the open surgery group. The duration of hospitalisation was 3.1±0.2 days, 1.2±0.3 days and 3.4±1.1 days respectively. While the RIRS group did not need blood transfusion, in the PNL group blood transfusions were given in the PNL (n=18), and open surgery (n=2) groups. Residual stones were detected in the PNL (n=22), open surgery (n=2), and RIRS (n=5) groups. PNL and RIRS have been seen as safe and effective methods in our self application too. However, it should not be forgotten that as a basical method, open surgery may be needed in cases of necessity.
Flexible ureterorenoscopy versus miniaturized PNL for solitary renal calculi of 10-30 mm size.
Knoll, Thomas; Jessen, Jan Peter; Honeck, Patrick; Wendt-Nordahl, Gunnar
2011-12-01
The value of flexible ureterorenoscopy (fURS) and miniaturized PNL (mPNL) for larger renal calculi is under discussion. This non-randomized prospective study aimed to evaluate fURS and mPNL for solitary renal stones of 10-30 mm size. fURS was carried out in 21 patients with last generation 7.5F endoscopes. Ureteral access sheaths were used in 19 patients. For mPNL, an 18F modified Amplatz sheath with a 14F nephroscope were used (n = 25). The procedure was performed either tubeless with an antegrade stent or a nephrostomy. Outcome and complications of both procedures were assessed. Patients' demographics and stone sizes were comparable (18 ± 5 vs. 19 ± 4 mm, P = 0.08). Patients in the fURS group had a higher mean BMI (31 vs. 27, P < 0.05). Total OR time was significantly longer for fURS (106 ± 51 vs. 59 ± 19 min., P < 0.001). More patients were stone-free after one single percutaneous treatment, while 2nd-stage treatments with fURS were common (total procedures 1.04 vs. 1.52, P < 0.001; immediate stone-free rate (SFR) 96% vs. 71.5%, P < 0.001). SFR after 4 weeks was 100% (mPNL) and 85.8% (fURS) (P < 0.01). Minor complications as classified by Clavien I or II occurred in 16 and 23.8%, mPNL and fURS, respectively, P = 0.13). No major complications (Clavien III-V) occured in both groups. Our series supports both the concept of either percutaneous or retrograde endoscopic treatment for renal calculi with both modalities offering excellent safety. However, while for fURS, a significantly higher rate of 2nd-stage procedures was necessary, and mPNL led to faster and higher SFR without increasing complication rate.
Wei, Yangdou; Shih, Jenny; Li, Jieran; Goodwin, Paul H
2002-07-01
Two pectin lyase genes, designated pnl-1 and pnl-2, were cloned from Colletotrichum gloeosporioides f. sp. malvae, a pathogen of round-leaved mallow (Malva pusilla). pnl-1 was isolated using cDNA from infected plant material; pnl-2 was isolated using cDNA from 3-day-old mycelia grown in mallow-cell-wall extract (MCWE) broth. pnl-1 is the first pectinase gene described thus far to encode a cellulose-binding domain (CBD), which is common in cellulases and xylanases, whereas pnl-2 encodes a pectin lyase that lacks a CBD. In pure culture, pnl-1 expression could be detected when purified pectin or glucose was the sole carbon source, but not when MCWE was the sole carbon source. The lack of pnl-1 expression appeared to be due to gene repression by some unknown factor(s) in the cell-wall extract. In contrast, expression of pnl-2 was detected in cultures when MCWE, but not when purified pectin or glucose, was the sole carbon source. In infected tissue, detection of pnl-1 expression by Northern-blot hybridization and by RT-PCR began with the onset of the necrotrophic phase of infection. Expression ofpnl-2 was not detectable by Northern-blot hybridization, but was observed byRT-PCR in both the biotrophic and necrotrophic phases of infection. The differences between pnl-1 and pnl-2 (i.e. pnl-1 encoding a CBD and differences in the expression patterns of both genes) may be related to the requirements of C. gloeosporioides f. sp. malvae to be able to grow in host tissue under the different conditions present during the biotrophic and necrotrophic phases of infection.
Evaluating Enhancements to a Perioperative Nurse Liaison Program
Hanson-Heath, Cathy Ann; Muller, Linda M.; Cunningham, Maureen F.
2016-01-01
The impetus for the Perioperative Nurse Liaison (PNL) program at our cancer center was to reduce anxiety for family members of patients undergoing surgery by improving communication between the family and the perioperative team. The purpose of our quality improvement project was to increase contact with family members during the patient’s surgery and to support families and surgeons during the postoperative family consult when findings were unexpected. After implementing process changes, the PNLs evaluated the program using a short survey given to families after the postoperative consult. Families reported a reduction in stress and anxiety when receiving intraoperative updates either in person or by telephone. In addition, when the PNL accompanied family members to the consult, the family felt supported when receiving unexpected findings. Further, family contact increased from 82% to 98% and consults with surgeons that included the PNL rose from an average of 254 to 500 per year. PMID:27004504
Pacific Northwest Laboratory annual report for 1992 to the DOE Office of Energy Research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grove, L.K.
1993-03-01
The 1992 Annual Report from Pacific Northwest Laboratory (PNL) to the US Department of Energy (DOE) describes research in environment and health conducted during fiscal year 1992. This report consists of four volumes oriented to particular segments of the PNL program, describing research performed for the DOE Office of Health and Environmental Research in the Office of Energy Research. The parts of the 1992 Annual Report are: Biomedical Sciences; Environmental Sciences; Atmospheric Sciences; and Physical Sciences. This Report is Part II: Environmental Sciences. Included in this report are developments in Subsurface Science, Terrestrial Science, Laboratory-Directed Research and Development, Interactions withmore » Educational Institutions, Technology Transfer, Publications, and Presentations. The research is directed toward developing a fundamental understanding of subsurface and terrestrial systems as a basis for both managing these critical resources and addressing environmental problems such as environmental restoration and global change. The Technology Transfer section of this report describes a number of examples in which fundamental research is laying the groundwork for the technology needed to resolve important environmental problems. The Interactions with Educational Institutions section of the report illustrates the results of a long-term, proactive program to make PNL facilities available for university and preuniversity education and to involve educational institutions in research programs. The areas under investigation include the effect of geochemical and physical phenomena on the diversity and function of microorganisms in deep subsurface environments, ways to address subsurface heterogeneity, and ways to determine the key biochemical and physiological pathways (and DNA markers) that control nutrient, water, and energy dynamics in arid ecosystems and the response of these systems to disturbance and climatic change.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grove, L.K.; Wildung, R.E.
1993-03-01
The 1992 Annual Report from Pacific Northwest Laboratory (PNL) to the US Department of Energy (DOE) describes research in environment and health conducted during fiscal year 1992. This report consists of four volumes oriented to particular segments of the PNL program, describing research performed for the DOE Office of Health and Environmental Research in the Office of Energy Research. The parts of the 1992 Annual Report are: Biomedical Sciences; Environmental Sciences; Atmospheric Sciences; and Physical Sciences. This Report is Part 2: Environmental Sciences. Included in this report are developments in Subsurface Science, Terrestrial Science, Laboratory-Directed Research and Development, Interactions withmore » Educational Institutions, Technology Transfer, Publications, and Presentations. The research is directed toward developing a fundamental understanding of subsurface and terrestrial systems as a basis for both managing these critical resources and addressing environmental problems such as environmental restoration and global change. The Technology Transfer section of this report describes a number of examples in which fundamental research is laying the groundwork for the technology needed to resolve important environmental problems. The Interactions with Educational Institutions section of the report illustrates the results of a long-term, proactive program to make PNL facilities available for university and preuniversity education and to involve educational institutions in research programs. The areas under investigation include the effect of geochemical and physical phenomena on the diversity and function of microorganisms in deep subsurface environments, ways to address subsurface heterogeneity, and ways to determine the key biochemical and physiological pathways (and DNA markers) that control nutrient, water, and energy dynamics in arid ecosystems and the response of these systems to disturbance and climatic change.« less
Cherniakov, Irina; Izgelov, Dvora; Barasch, Dinorah; Davidson, Elyad; Domb, Abraham J; Hoffman, Amnon
2017-11-28
Nowadays, therapeutic indications for cannabinoids, specifically Δ 9 -tetrahydrocannabinol (THC) and Cannabidiol (CBD) are widening. However, the oral consumption of the molecules is very limited due to their highly lipophilic nature that leads to poor solubility at the aqueous environment. Additionally, THC and CBD are prone to extensive first pass mechanisms. These absorption obstacles render the molecules with low and variable oral bioavailability. To overcome these limitations we designed and developed the advanced pro-nanolipospheres (PNL) formulation. The PNL delivery system is comprised of a medium chain triglyceride, surfactants, a co-solvent and the unique addition of a natural absorption enhancer: piperine. Piperine was selected due to its distinctive inhibitory properties affecting both Phase I and Phase II metabolism. This constellation self emulsifies into nano particles that entrap the cannabinoids and the piperine in their core and thus improve their solubility while piperine and the other PNL excipients inhibit their intestinal metabolism. Another clear advantage of the formulation is that its composition of materials is approved for human consumption. The safe nature of the excipients enabled their direct evaluation in humans. In order to evaluate the pharmacokinetic profile of the THC-CBD-piperine-PNL formulation, a two-way crossover, single administration clinical study was conducted. The trial comprised of 9 healthy volunteers under fasted conditions. Each subject received a THC-CBD (10.8mg, 10mg respectively) piperine (20mg)-PNL filled capsule and an equivalent dose of the oromucosal spray Sativex® with a washout period in between treatments. Single oral administration of the piperine-PNL formulation resulted in a 3-fold increase in Cmax and a 1.5-fold increase in AUC for THC when compared to Sativex®. For CBD, a 4-fold increase in Cmax and a 2.2-fold increase in AUC was observed. These findings demonstrate the potential this formulation has in serving as a standardized oral cannabinoid formulation. Moreover, the concept of improving oral bioavailability described here, can pave the way for other potential lipophilic active compounds requiring enhancement of their oral bioavailability. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
The Pacific Northwest Laboratory (PNL), operated by Battelle Memorial Institute under contract to the U.S. Department of Energy, operates tank systems for the U.S. Department of Energy, Richland Operations Office (DOE-RL), that contain dangerous waste constituents as defined by Washington State Department of Ecology (WDOE) Dangerous Waste Regulations, Washington Administrative Code (WAC) 173-303-040(18). Chapter 173-303-640(2) of the WAC requires the performance of integrity assessments for each existing tank system that treats or stores dangerous waste, except those operating under interim status with compliant secondary containment. This Integrity Assessment Plan (IAP) identifies all tasks that will be performed during the integritymore » assessment of the PNL-operated Radioactive Liquid Waste Systems (RLWS) associated with the 324 and 325 Buildings located in the 300 Area of the Hanford Site. It describes the inspections, tests, and analyses required to assess the integrity of the PNL RLWS (tanks, ancillary equipment, and secondary containment) and provides sufficient information for adequate budgeting and control of the assessment program. It also provides necessary information to permit the Independent, Qualified, Registered Professional Engineer (IQRPE) to approve the integrity assessment program.« less
Pacific Northwest Laboratory annual report for 1990 to the DOE Office of Energy Research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Owczarski, E.L.
At the start of FY 1990, the atmospheric sciences and carbon dioxide research programs within the Office of Health and Environmental Research (OHER) were gathered into the new Atmospheric and Climate Research Division (ACRD). One of the central missions of this new division is to provide the Department of Energy with scientifically defensible information on the local, regional, and global distributions of energy-related pollutants and their effects on climate. This information is vital to the definition and implementation of a sound national energy strategy. Because much of the work done at PNL during FY 1990 falls under the umbrella ofmore » the new ACRD, we are including in this volume the progress and status reports for all OHER atmospheric and climate research projects at PNL. The description of ongoing atmospheric and climate research at PNL is organized along two broad research areas; atmospheric research and climate research. This report describes the progress in FY 1990 in each of these areas. A divider page summarizes the goals of each area and lists projects that support research activities.« less
Qi, Shiyong; Li, Li; Liu, Ranlu; Qiao, Baomin; Zhang, Zhihong; Xu, Yong
2014-02-01
To determine the impact of staghorn calculi branch number on outcomes of percutaneous nephrolithotomy (PNL). Retrospectively, we evaluated 371 patients (386 renal units) who underwent PNL for staghorn calculi. All calculi were showed with CT three-dimensional reconstruction (3DR) imaging preoperatively. From 3DR images, the number of stone branching into minor renal calices was recorded. According to the number, patients were divided into four groups. Group 1: the branch number 2-4; Group 2: the branch number 5-7; Group 3: the branch number 8-10; Group 4: the branch number >10. The number of percutaneous tract, operative time, staged PNL, intraoperative blood loss, postoperative hospital stay, complications, main stone composition, and stone clearance rate were compared. A significantly higher ratio of multitract (p<0.001) and staged PNL (p<0.001), a longer operative time (p<0.001) and postoperative hospital stay (p=0.043), and a lower rate of stone clearance (p<0.05) were found in PNL for calculi with a stone branch number ≥5. There was no statistical difference in intraoperative blood loss (p=0.101) and main stone composition (p=0.546). There was no statistically meaningful difference among the four groups based on the Clavien complication system (p=0.46). With the stone branch number more than five, the possibility of multitract and staged PNL, lower rate of stone clearance, and a longer postoperative hospital stay increases for staghorn calculi.
Romualdo, Guilherme Ribeiro; Goto, Renata Leme; Henrique Fernandes, Ana Angélica; Cogliati, Bruno; Barbisan, Luis Fernando
2016-10-01
Although there is a concomitance of zinc deficiency and high incidence/mortality for hepatocellular carcinoma in certain human populations, there are no experimental studies investigating the modifying effects of zinc on hepatocarcinogenesis. Thus, we evaluated whether dietary zinc deficiency or supplementation alter the development of hepatocellular preneoplastic lesions (PNL). Therefore, neonatal male Balb/C mice were submitted to a diethylnitrosamine/2-acetylaminefluorene-induced hepatocarcinogenesis model. Moreover, mice were fed adequate (35 mg/kg diet), deficient (3 mg/kg) or supplemented (180 mg/kg) zinc diets. Mice were euthanized at 12 (early time-point) or 24 weeks (late time-point) after introducing the diets. At the early time-point, zinc deficiency decreased Nrf2 protein expression and GSH levels while increased p65 and p53 protein expression and the number of PNL/area. At the late time-point, zinc deficiency also decreased GSH levels while increased liver genotoxicity, cell proliferation into PNL and PNL size. In contrast, zinc supplementation increased antioxidant defense at both time-points but not altered PNL development. Our findings are the first to suggest that zinc deficiency predisposes mice to the PNL development in chemically-induced hepatocarcinogenesis. The decrease of Nrf2/GSH pathway and increase of liver genotoxicity, as well as the increase of p65/cell proliferation, are potential mechanisms to this zinc deficiency-mediated effect. Copyright © 2016 Elsevier Ltd. All rights reserved.
Pacific Northwest Laboratory Institutional Plan FY 1995-2000
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1994-12-01
This report serves as a document to describe the role PNL is positioned to take in the Department of Energy`s plans for its national centers in the period 1995-2000. It highlights the strengths of the facilities and personnel present at the laboratory, touches on the accomplishments and projects they have contributed to, and the direction being taken to prepare for the demands to be placed on DOE facilities in the near and far term. It consists of sections titled: director`s statement; laboratory mission and core competencies; laboratory strategic plan; laboratory initiatives; core business areas; critical success factors.
Incidence of retrorenal colon during percutaneous nephrolithotomy
Balasar, Mehmet; Kandemir, Abdülkadir; Poyraz, Necdet; Unal, Yunus; Ozturk, Ahmet
2015-01-01
Objective The aim of this study was to investigate retrorenal colon incidence in percutaneous nephrolithotomy (PNL) interventions made in our clinic. Materials and Methods Clinical data of 804 PNL patients, accumulated over a 7 year period (2006-2012), was surveyed. The patient files were reviewed retrospectively, and only those who had abdominal computed tomography (CT) images before PNL intervention were included in the study. In the CT images, the position of both the ascending and descending colon in relation to the right and left kidneys were evaluated. Results According to our hospital reports, 394 patients with CT images were included in the present study 27 patients (6.9%) had retrorenal colon, of which 18 (4.6%) were on the left side, 4 (1.0%) on the right side and 5 (1.3%) had bilateral retrorenal colons. Colonic perforation complication was seen only in two patients and the colonic perforation rate was 0.3%. These two cases had no CT images. Conclusions PNL, in the process of becoming the standard treatment modality, is a safe and reliable technique for renal stone treatment. Colonic injury should be taken into consideration during PNL interventions of the lower pole of the kidney (especially on the left side) due to the location of retrorenal colon. PMID:26005968
Federal Energy Decision Screening (FEDS) process at Fort Drum, New York
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dixon, D.R.; Daellenbach, K.K.; Rowley, S.E.
1993-10-01
The federal energy manager has been directed by the Comprehensive Energy Policy Act of 1992 (EPAct) to reduce energy consumption by 20% from 1985 levels, by the year 2000. However, the tools and funding to capture this resource in a cost-effective manner have not been provided. In an effort to assist federal agencies in meeting EPAct requirements, the Pacific Northwest Laboratory (PNL) has been tasked by the US Army Forces Command (FORSCOM) to identify, evaluate, and acquire all cost-effective energy projects at selected federal facilities. PNL has developed and applied the Federal Energy Decision Screening (FEDS) methodology at the Fortmore » Drum FORSCOM facility near Watertown, New York. The FEDS methodology is a systematic approach to evaluating energy opportunities that result in a roadmap to significantly reduce energy use in a planned, rational, cost justified fashion over a 5 to 10 year period. At Fort Drum, the net present value (NPV) of the installed cost of all cost-effective energy resource opportunities (EROS) is over $16 million (1992 $). The NPV of the savings associated with this investment is nearly $47 million (1992 $), for an overall NPV of approximately $31 million. By implementing all the cost-effective EROS, Fort Drum will reduce annual energy use by over 230,000 MBtu, or 15%. Annual energy expenditures will decrease by over $2.4 million, or a 20% reduction.« less
Percutaneous Nephrolithotomy in Patients With BMI >50: Single Surgeon Outcomes and Feasibility.
Streeper, Necole M; Radtke, Andrew C; Penniston, Kristina L; McDermott, John C; Nakada, Stephen Y
2016-01-01
To evaluate the use of percutaneous nephrolithotomy (PNL) and technical approach in the super obese population (body mass index [BMI] ≥ 50). We performed a retrospective review of 31 consecutive PNL cases with a BMI > 50 from a single surgeon (SYN) from 1995 to 2013. Procedures were performed in the prone position, and upper pole access was used. Operative time, length of hospital stay, stone burden, complication rates, and stone-free rates were measured. Of the 31 patients who underwent PNL (age 51.2 ± 12; 71% female), the mean BMI was 59.1 ± 6 kg/m(2) (range 50.4-71.7 kg/m(2)). Mean stone burden was 3.8 cm ± 2. The majority of patients (90.3%) had an upper pole puncture site for access with an operative time of 122.1 ± 75 minutes. The technique was similar to non-obese patients; however, there was a need for extra-long instrumentation. The overall stone-free rate was 71%, with utilization of a second-look PNL in 11 cases. The complication rate, Clavien grade 3 or higher, was 9.7% (3 of 31). PNL is technically feasible, safe, and effective in patients with a BMI ≥ 50. The complication rate, length of hospital stay, and stone-free rate with use of second-look PNL in super obese patients are comparable to severely obese patients. Intervention should not be automatically ruled out or delayed based on the patient's BMI alone. Copyright © 2015 Elsevier Inc. All rights reserved.
Mini vs standard percutaneous nephrolithotomy for renal stones: a comparative study.
ElSheemy, Mohammed S; Elmarakbi, Akram A; Hytham, Mohammed; Ibrahim, Hamdy; Khadgi, Sanjay; Al-Kandari, Ahmed M
2018-03-16
To compare the outcome of mini-percutaneous nephrolithotomy (Mini-PNL) versus standard-PNL for renal stones. Retrospective study was performed between March 2010 and May 2013 for patients treated by Mini-PNL or standard-PNL through 18 and 30 Fr tracts, respectively, using pneumatic lithotripsy. Semirigid ureteroscope (8.5/11.5 Fr) was used for Mini-PNL and 24 Fr nephroscope for standard-PNL. Both groups were compared in stone free rate(SFR), complications and operative time using Student-t, Mann-Whitney, Chi square or Fisher's exact tests as appropriate in addition to logistic regression analysis. P < 0.05 was considered statistically significant. Mini-PNL (378) and standard-PNL (151) were nearly comparable in patients and stones criteria including stone burden (3.77 ± 2.21 vs 3.77 ± 2.43 cm 2 ; respectively). There was no significant difference in number of tracts or supracostal puncture. Mini-PNL had longer operative time (68.6 ± 29.09 vs 60.49 ± 11.38 min; p = 0.434), significantly shorter hospital stay (2.43 ± 1.46 vs 4.29 ± 1.28 days) and significantly higher rate of tubeless PNL (75.1 vs 4.6%). Complications were significantly higher in standard-PNL (7.9 vs 20.5%; p < 0.001). SFR was significantly lower in Mini-PNL (89.9 vs 96%; p = 0.022). This significant difference was found with multiple stones and large stone burden (> 2 cm 2 ), but the SFR was comparable between both groups with single stone or stone burden ≤ 2 cm. Logistic regression analysis confirmed significantly higher complications and SFR with standard-PNL but with significantly shorter operative time. Mini-PNL has significantly lower SFR when compared to standard-PNL (but clinically comparable) with markedly reduced complications and hospital stay. Most of cases can be performed tubeless. The significant difference in SFR was found with multiple stones or large stone burden (> 2 cm 2 ), but not with single stones or stone burden ≤ 2 cm 2 .
Mini-percutaneous nephrolithotomy for stones in anomalous-kidneys: a prospective study.
Khadgi, Sanjay; Shrestha, Babu; Ibrahim, Hamdy; Shrestha, Sunil; ElSheemy, Mohammed S; Al-Kandari, Ahmed M
2017-08-01
To evaluate safety and efficacy of minipercutaneous nephrolithotomy (Mini-PNL) in management of stones in different types of renal anomalies. Patients with stones ≥2 cm or SWL-resistant stones in anomalous-kidneys treated by Mini-PNL between March 2010 and September 2012 were included prospectively. Mini-PNL was done under regional anesthesia in prone position with fluoroscopic guidance through 18 Fr sheath using semirigid ureteroscope (8.5/11.5 Fr) and pneumatic lithotripter. All patients were followed-up for 2-3 years. Stone-free rate was defined as absence of residual fragments ≥2 mm. Student-T, Mann-Whitney, Chi square (χ 2 ), Fisher-exact, one way ANOVA or Kruskal-Wallis test were used for analysis. Mini-PNL was performed for 59 patients (20 horseshoe, 15 malrotated, 7 polycystic, 13 duplex and 4 ectopic pelvic-kidneys). Mean age was 40.18 ± 12.75 (14-78) years. Mean stone burden was 31.72 ± 21.43 (7.85-141.3) mm 2 . Two tracts were required in 7 (11.9 %) patients. Tubeless Mini-PNL with double-J insertion was performed in all patients except two. Operative time was 50.17 ± 18.73 (15-105) min. Hemoglobin loss was 0.44 ± 0.30 (0-1.4) g/dL. Complications were reported in 15 (25.4 %) patients. No pleural injury, sepsis, perinephric-collection or renal-pelvis perforation were reported. Stone-free rate was 89.8 % (converted to open-surgery in one patient, second-look PNL in two patients, auxiliary SWL in three patients). Stone-free rate improved to 98.3 % after retreatment and auxiliary SWL. Site of puncture was mostly upper calyceal in horseshoe-kidney (80 %), mid calyceal in polycystic-kidney (85.7 %) and lower calyceal in duplex-kidney (46.2 %). Punctures were also significantly infracostal in horseshoe-kidney (100 %) and supracostal in both duplex (53.8 %) and malrotated-kidneys (66.7 %). Mini-PNL is safe for management of stones in anomalous-kidney with SFR comparable to standard-PNL but with less complications.
Estimates of emergency operating capacity in US manufacturing and nonmanufacturing industries
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belzer, D.B.; Serot, D.E.; Kellogg, M.A.
1991-03-01
Development of integrated mobilization preparedness policies requires planning estimates of available productive capacity during national emergency conditions. Such estimates must be developed in a manner that allows evaluation of current trends in capacity and the consideration of uncertainties in various data inputs and in engineering assumptions. This study, conducted by Pacific Northwest Laboratory (PNL), developed estimates of emergency operating capacity (EOC) for 446 manufacturing industries at the 4-digit Standard Industrial Classification (SIC) level of aggregation and for 24 key non-manufacturing sectors. This volume presents tabular and graphical results of the historical analysis and projections for each SIC industry. (JF)
Geomorphologic Modeling of a Macro-Tidal Embayment With Extensive Tidal Flats: Skagit Bay, WA
2009-01-01
Tidal Flats: Skagit Bay , WA Lyle Hibler Pacific Northwest National Laboratory 1529 West Sequim Bay Road Sequim , WA 98382 phone: (360) 681...3616 fax: (360) 681-3681 email: lyle.hibler@pnl.gov Adam Maxwell Pacific Northwest National Laboratory 1529 West Sequim Bay Road Sequim , WA... Sequim Bay Road, Sequim ,WA,98382 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR
Geomorphologic Modeling of a Macro-tidal Embayment with Extensive Tidal Flats: Skagit Bay, WA
2008-01-01
Bay , WA Lyle Hibler Pacific Northwest National Laboratory 1529 West Sequim Bay Road Sequim , WA 98382 phone: (360) 681-3616 fax: (360)681-3681...email: lyle.hibler@pnl.gov Adam Maxwell Pacific Northwest National Laboratory 1529 West Sequim Bay Road Sequim , WA 98382 phone: (360) 681... Sequim Bay Road, Sequim ,WA,98382 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10.
Klein, Jan Thorsten; Rassweiler, Jens; Rassweiler-Seyfried, Marie-Claire Charlotte
2018-03-29
Nephrolithiasis is one of the most common diseases in urology. According to the EAU Guidelines, a percutaneous nephrolitholapaxy (PNL) is recommended when treating a kidney stone >2 cm. Nowadays PNL is performed even for smaller stones (<1 cm) using miniaturized instruments. The most challenging part of any PNL is the puncture of the planned site. PNL-novice surgeons need to practice this step in a safe environment with an ideal training model. We developed and evaluated a new, easy to produce, in-vitro model for the training of the freehand puncture of the kidney. Porcine kidneys with ureters were embedded in ballistic gel. Food coloring and preservative agent were added. We used the standard imaging modalities of X-ray and ultrasound to validate the training model. An additional new technique, the iPAD guided puncture, was evaluated. Five novices and three experts conducted 12 punctures for each imaging technique. Puncture time, radiation dose, and number of attempts to a successful puncture were measured. Mann-Whitney-U, Kruskal-Wallis, and U-Tests were used for statistical analyses. The sonographic guided puncture is slightly but not significantly faster than the fluoroscopic guided puncture and the iPAD assisted puncture. Similarly, the most experienced surgeon's time for a successful puncture was slightly less than that of the residents, and the experienced surgeons needed the least attempts to perform a successful puncture. In terms of radiation exposure, the residents had a significant reduction of radiation exposure compared to the experienced surgeons. The newly developed ballistic gel kidney-puncture model is a good training tool for a variety of kidney puncture techniques, with good content, construct, and face validity.
Süelözgen, Tufan; Isoglu, Cemal Selcuk; Turk, Hakan; Yoldas, Mehmet; Karabicak, Mustafa; Ergani, Batuhan; Boyacioglu, Hayal; Ilbey, Yusuf Ozlem; Zorlu, Ferruh
2016-01-01
This study aimed to evaluate whether one-shot dilatation technique is as safe in patients with a history of open-stone surgery as it is in patients without previous open-stone surgery. Between January 2007 and February 2015, 82 patients who underwent percutaneous nephrolithotomy (PNL) surgery with one-shot dilation technique who previously had open-stone surgery were retrospectively reviewed and evaluated (Group 1). Another 82 patients were selected randomly among patients who had PNL with one-shot dilation technique, but with no history of open renal surgery (Group 2). Age, gender, type of kidney stone, duration of surgery, radiation exposure time, and whether or not there was any bleeding requiring perioperative and postoperative transfusion were noted for each patient. The stone-free rates, operation and fluoroscopy time, and peroperative and postoperative complication rates were similar in both groups (p>0.05). Our experience indicated that PNL with one-shot dilation technique is a reliable method in patients with a history of open-stone surgery.
Bas, Okan; Ozyuvali, Ekrem; Aydogmus, Yasin; Sener, Nevzat Can; Dede, Onur; Ozgun, Serhat; Hizli, Fatih; Senocak, Cagri; Bozkurt, Omer Faruk; Basar, Halil; Imamoglu, Abdurrahim
2015-04-01
To compare the outcomes in patients who have been treated with flexible ureterorenoscopy (f-URS) and percutaneous nephrolithotomy (PNL) in managing stone-bearing caliceal diverticula. Between April 2007 and October 2013, we performed a retrospective analysis of 54 evaluable patients (28 women and 26 men) with symptomatic stone-bearing caliceal diverticula, who underwent PNL (n = 29) or F-URS (n = 25) in four referral hospitals in Turkey. The groups were compared with respect to demographics, stone location/size, success rate, stone-free status, symptom-free status, complication rates, and hospital stay. The average stone burden preoperatively was significantly larger in patients who were treated with PNL, with the average size for f-URS being 154 ± 77 mm(2) and that for PNL being 211 ± 97 mm(2) (p = 0.023). Symptom-free rates, success rates, stone-free rates and clinically insignificant residual fragments were similar between the groups (p = 0.880 vs. p = 0.537 vs. p = 0.539, and p = 0.877, respectively). There was no statistical difference between the groups for minor complications (p = 0.521) but no major complication (Clavien III-V) occured in the f-URS group; although there were three major complications (10.3 %) (Clavien III) in the PNL group (p < 0.001). Hospitalization time per patient was 1.04 ± 0.20 days in the f-URS group, while it was 3.86 ± 1.94 days in the PNL group (p < 0.001). Even though this study clearly shows that both techniques have high overall success and symptom-free rates with similar complication rates for stone-bearing calyceal diverticulum, major complication rates may suggest consideration of the invasiveness of PNL. The f-URS procedure is advantageous with respect to a shorter hospital stay and absence of major complications. Therefore, it should be emphasized that the location of the stone and diverticula is an important factor for the selection of the procedure.
PCDAS Version 2. 2: Remote network control and data acquisition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fishbaugher, M.J.
1987-09-01
This manual is intended for both technical and non-technical people who want to use the PCDAS remote network control and data acquisition software. If you are unfamiliar with remote data collection hardware systems designed at Pacific Northwest Laboratory (PNL), this introduction should answer your basic questions. Even if you have some experience with the PNL-designed Field Data Acquisition Systems (FDAS), it would be wise to review this material before attempting to set up a network. This manual was written based on the assumption that you have a rudimentary understanding of personal computer (PC) operations using Disk Operating System (DOS) versionmore » 2.0 or greater (IBM 1984). You should know how to create subdirectories and get around the subdirectory tree.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wise, B.K.; Hughes, K.R.; Danko, S.L.
1994-07-01
This report was prepared for the US Department of Energy (DOE) Office of Codes and Standards by the Pacific Northwest Laboratory (PNL) through its Building Energy Standards Program (BESP). The purpose of this task was to identify demand-side management (DSM) strategies for new construction that utilities have adopted or developed to promote energy-efficient design and construction. PNL conducted a survey of utilities and used the information gathered to extrapolate lessons learned and to identify evolving trends in utility new-construction DSM programs. The ultimate goal of the task is to identify opportunities where states might work collaboratively with utilities to promotemore » the adoption, implementation, and enforcement of energy-efficient building energy codes.« less
Hanford Internal Dosimetry Project manual. Revision 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carbaugh, E.H.; Bihl, D.E.; MacLellan, J.A.
1994-07-01
This document describes the Hanford Internal Dosimetry Project, as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy and its Hanford contractors. Project services include administrating the bioassay monitoring program, evaluating and documenting assessment of potential intakes and internal dose, ensuring that analytical laboratories conform to requirements, selecting and applying appropriate models and procedures for evaluating radionuclide deposition and the resulting dose, and technically guiding and supporting Hanford contractors in matters regarding internal dosimetry. Specific chapters deal with the following subjects: practices of the project, including interpretation of applicable DOE Orders, regulations, andmore » guidance into criteria for assessment, documentation, and reporting of doses; assessment of internal dose, including summary explanations of when and how assessments are performed; recording and reporting practices for internal dose; selection of workers for bioassay monitoring and establishment of type and frequency of bioassay measurements; capability and scheduling of bioassay monitoring services; recommended dosimetry response to potential internal exposure incidents; quality control and quality assurance provisions of the program.« less
De, Abhishek; Hasanoor Reja, Abu Hena; Aggarwal, Ishad; Sen, Sumit; Sil, Amrita; Bhattacharya, Basudev; Sharma, Nidhi; Ansari, Asad; Sarda, Aarti; Chatterjee, Gobinda; Das, Sudip
2017-01-01
Pure neural leprosy (PNL) still remains a diagnostic challenge because of the absence of sine qua non skin lesions of leprosy and a confirmatory diagnostic method. The authors had earlier described a simple yet objective technique of combining fine needle aspiration cytology (FNAC) coupled with a multiplex polymerase chain reaction (PCR) in a pilot study, wherein the technique showed promise of a reliable diagnostic tool. In the pursuit of further evidence, the authors carried out a 4-year study with PNL cases to find the efficacy and reliability of the said method in a larger sample size. This study was conducted to find the efficacy, reliability, and reproducibility of FNAC coupled with multiplex PCR and Ziehl-Neelsen (ZN) staining in identifying the cases of PNL. All cases that were suspected to be suffering from PNL, following evaluation by two independent observers were included in the study and were subjected to FNAC from the affected nerve, and the aspirates were evaluated for cytology, ZN staining, and multiplex PCR for Mycobacterium leprae genome. In addition, serum anti-PGL1 levels were also performed in all the study subjects. Fifteen non-PNL cases were also included in the control arm. A total of 47 cases were included in the test arm and subjected to FNAC. Conventional ZN staining could demonstrate acid-fast bacilli (AFB) in only 15 out of 47 cases (31.91%) while M. leprae DNA could be elicited in 37 (78.72%) cases by the multiplex PCR. Only 13 (27.65%) out of 47 cases showed anti-PGLI-1 antibody positivity. On cytological examination of the nerve aspirates, only 11 (23.40%) cases showed epithelioid cells whereas nonspecific inflammation was seen in 26 (75.60%) cases. The results of this study conducted over a larger sample size corroborate with the findings of our pilot study. In a resource poor set up, FNAC in combination with ZN staining and multiplex PCR is a rapid, simple, and easily performed test, which can give a reproducible and objective diagnosis in cases of PNL.
Surgical management of urinary stones with abnormal kidney anatomy.
Ergin, Giray; Kirac, Mustafa; Unsal, Ali; Kopru, Burak; Yordam, Mustafa; Biri, Hasan
2017-04-01
In spite of the fact that urologic surgical techniques used by urologists are becoming more and more minimally invasive and easier because of developing technologies, surgical approaches for the urinary stones in kidneys with abnormal anatomy are still confusing. The objective of this article is to determine the treatment options in these kidneys. For this purpose, between 2005 and 2015, we retrospectively evaluated patients operated for urolithiasis with various congenital renal anomalies in five referral urology clinics in our country. Of the 178 patients (110 male, 60 female), 96 had horseshoe kidneys, 42 had pelvic ectopic kidneys (PEKs), and 40 had isolated rotation anomalies (IRAs) of the kidney. We evaluated the patients for stone-free rate (SFR), mean operation time, mean hospitalization time, and complication rate. In horseshoe kidney, SFRs for retrograde intrarenal surgery (RIRS) and percutaneous nephrolithotomy (PNL) groups were 72.2% and 90%, respectively. In PEKs, these rates were 83.6% and 100% for RIRS and laparoscopic pyelolithotomy, respectively. SFRs in kidneys with IRA were 75% for RIRS and 83.3% for PNL. The mean operation time for RIRS and PNL groups in horseshoe kidney was 40.5±11.2 minutes and 74.5±19.3 minutes, respectively. In PEKs, these times were 52.1±19.3 minutes and 53.1±24.3 minutes for RIRS and laparoscopic pyelolithotomy, respectively. Mean operation time in kidneys with IRA was 48.7±14.4 minutes for RIRS and 53.2±11.3 minutes for PNL. Mean hospitalization times for RIRS and PNL groups in horseshoe kidneys were 1.4±0.7 days and 2.2±1.4 days, respectively. In PEKs, these times were 2.7±1.8 days and 1.9±0.4 days for RIRS and laparoscopic pyelolithotomy, respectively. Mean operation time in kidneys with IRA was 1.5±0.9 days for RIRS and 1.8±0.6 days for PNL. The results of our study showed that RIRS could be used in all of types of abnormal kidneys with small- and medium-sized renal calculi safely and satisfactorily. Copyright © 2017. Published by Elsevier Taiwan.
Pacific Northwest Laboratory annual report for 1990 to the DOE Office of Energy Research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Toburen, L.H.; Stults, B.R.; Mahaffey, J.A.
Part four of the PNL Annual Report for 1990 includes research in physical sciences. Individual reports are processed separately for the data bases in the following areas: Dosimetry Research; Measurement Science; Radiological and Chemical Physics; Radiation Dosimetry; Radiation Biophysics; and Modelling Cellular Response to Genetic Damage. (FL)
Special meteorological and atmospheric tracer studies were conducted during a three-week period in July and August of 1982 in the Brush Creek Valley of northwestern Colorado. The experiments were conducted by the U.S. Department of Energy's Pacific Northwest Laboratory (PNL) as p...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, J.F.
This report summarizes progress on OHER human health, biological, general life sciences, and medical applications research programs conducted at PNL in FY 1989. The research develops the knowledge and scientific principles necessary to identify, understand, and anticipate the long-term health consequences of energy-related radiation and chemicals. Our continuing emphasis is to decrease the uncertainty of health risk estimates from existing and developing energy-related technologies through an increased understanding of how radiation and chemicals cause biological damage. The sequence of this report of PNL research reflects the OHER programmatic structure. The first section, on human health research, concerns statistical and epidemiologicalmore » studies for assessing health risks. The next section contains reports of biological research in laboratory animals and in vitro cell systems, including research with radionuclides and chemicals. The general life sciences research section reports research conducted for the OHER human genome research program, and the medical applications section summarizes commercial radioisotope production and distribution activities at DOE facilities. 6 refs., 50 figs., 35 tabs.« less
Xu, S X; Qin, X; Liu, B; Zhang, D Q; Zhang, W; Wu, K; Zhang, Y H
2015-02-01
The pectin lyase gene pnl-zj5a from Aspergillus niger ZJ5 was identified and expressed in Pichia pastoris. PNL-ZJ5A was purified by ultrafiltration, anion exchange and gel chromatography. The Km and Vmax values determined using citrus pectin were 0.66 mg ml(-1) and 32.6 μmol min(-1) mg(-1) , respectively. PNL-ZJ5A exhibited optimal activity at 43°C and retained activity over 25-50°C. PNL-ZJ5A was optimally active at pH 5 and effective in apple juice clarification. Compared with controls, PNL-ZJ5A increased the fruit juice yield significantly. Furthermore, PNL-ZJ5A reduced the viscosity of apple juice by 38.8% and increased its transmittance by 86.3%. PNL-ZJ5A combined with a commercial pectin esterase resulted in higher juice volume. © 2014 The Society for Applied Microbiology.
Irlé, C; Piguet, P F; Vassalli, P
1978-07-01
Peanut lectin (PNL) binds to a majority of mouse thymocytes (Thc) in suspension. By using cell affinity chromatography on a column of anti-PNL antibody, Thc populations at least 96 percent pure in PNL + or - cells, as judged by immunofluorescence, were obtained. PNL(+) cells are rich in Thy 1 and poor in H(2) antigens, cortisone sensitive, unresponsive to phytohemagglutinin (PHA), and immunologically incompetent, as judged by mixed lymphocyte reaction, popliteal lymph node graft-versus-host assay, and by testing helper activity in a primary in vitro antibody response to sheep erythrocytes; the converse is true of PNL(-) cells. Thus, PNL(+) and (-) cells appear to correspond to cortical and medullary Thc, respectively, as previously suggested. In culture, PNL(+) Thc show poor viability and a weak proliferative response to concanavalin A (Con A), except when supernate (SUP) of 24 h Con A stimulated lymph node lymphocyte cultures, or irradiated lymph node cells, are added, in which cases a strong proliferative response to the mitogen is observed. A variety of control experiments showed that the proliferating cells did not result from preferential stimulation of a few contaminating PNL(-) Thc present in the PNL(+) Thc cultures. The blasts resulting from PNL(+) Thc proliferation display mitogen-induced cytotoxicity, and give rise to a population of medium-sized lymphocytes, mostly PNL(-), poor in Thy 1 and rich in H(2) antigens, PHA responsive, and immunologically competent in the above-mentioned assays. Fresh PNL(+) Thc responded in mixed lymphocyte reaction in the presence of SUP (lectin depleted) and since incubation in SUP alone did not confer reactivity on PNL(+) Thc, it appears therefore that (a) immature Thc possess alloantigen and mitogen-specific surface receptors but lack the capacity to respond by proliferation to receptor triggering without the help of extracellular factor(s) released by mature lymphoid cells stimulated by mitogens (b) cell division is associated with the acquisition of immunological responsiveness, characteristic of mature T lymphocytes. The implications of these findings for the ontogenesis of thymus-derived lymphocytes, and for the possible traffic of Thc within and from the thymus, are discussed.
Bowen, J K; Templeton, M D; Sharrock, K R; Crowhurst, R N; Rikkerink, E H
1995-01-20
The feasibility of performing routine transformation-mediated mutagenesis in Glomerella cingulata was analysed by adopting three one-step gene disruption strategies targeted at the pectin lyase gene pnlA. The efficiencies of disruption following transformation with gene replacement- or gene truncation-disruption vectors were compared. To effect replacement-disruption, G. cingulata was transformed with a vector carrying DNA from the pnlA locus in which the majority of the coding sequence had been replaced by the gene for hygromycin B resistance. Two of the five transformants investigated contained an inactivated pnlA gene (pnlA-); both also contained ectopically integrated vector sequences. The efficacy of gene disruption by transformation with two gene truncation-disruption vectors was also assessed. Both vectors carried at 5' and 3' truncated copy of the pnlA coding sequence, adjacent to the gene for hygromycin B resistance. The promoter sequences controlling the selectable marker differed in the two vectors. In one vector the homologous G. cingulata gpdA promoter controlled hygromycin B phosphotransferase expression (homologous truncation vector), whereas in the second vector promoter elements were from the Aspergillus nidulans gpdA gene (heterologous truncation vector). Following transformation with the homologous truncation vector, nine transformants were analysed by Southern hybridisation; no transformants contained a disrupted pnlA gene. Of nineteen heterologous truncation vector transformants, three contained a disrupted pnlA gene; Southern analysis revealed single integrations of vector sequence at pnlA in two of these transformants. pnlA mRNA was not detected by Northern hybridisation in pnlA- transformants. pnlA- transformants failed to produce a PNLA protein with a pI identical to one normally detected in wild-type isolates by silver and activity staining of isoelectric focussing gels. Pathogenesis on Capsicum and apple was unaffected by disruption of the pnlA gene, indicating that the corresponding gene product, PNLA, is not essential for pathogenicity. Gene disruption is a feasible method for selectively mutating defined loci in G. cingulata for functional analysis of the corresponding gene products.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keller, J.M.; Dittmer, A.L.; Elliott, D.B.
1995-02-01
The U.S. Army Forces Command (FORSCOM) has tasked the U.S. Department of Energy (DOE) Federal Energy Management Program (FEMP), supported by the Pacific Northwest Laboratory, to identify, evaluate, and assist in acquiring all cost-effective energy projects at Fort Irwin. This is part of a model program that PNL is designing to support energy-use decisions in the federal sector. This report provides the results of the fossil fuel and electric energy resource opportunity (ERO) assessments performed by PNL at the FORSCOM Fort Irwin facility located near Barstow, California. It is a companion report to Volume 1, Executive Summary, and Volume 2,more » Baseline Detail. The results of the analyses of EROs are presented in 16 common energy end-use categories (e.g., boilers and furnaces, service hot water, and building lighting). A narrative description of each ERO is provided, along with a table detailing information on the installed cost, energy and dollar savings; impacts on operations and maintenance (O&M); and, when applicable, a discussion of energy supply and demand, energy security, and environmental issues. A description of the evaluation methodologies and technical and cost assumptions is also provided for each ERO. Summary tables present the cost-effectiveness of energy end-use equipment before and after the implementation of each ERO and present the results of the life-cycle cost (LCC) analysis indicating the net present valve (NPV) and savings-to-investment ratio (SIR) of each ERO.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sullivan, G.P.; Keller, J.M.; Stucky, D.J.
The US Army Forces Command (FORSCOM) has tasked the US Department of Energy (DOE) Federal Energy Management Program (FEMP), supported by the Pacific Northwest Laboratory, to identify, evaluate, and assist in acquiring all cost-effective energy projects at Fort Stewart. This is part of a model program that PNL is designing to support energy-use decisions in the federal sector. This report provides the results of the fossil fuel and electric energy resource opportunity (ERO) assessments performed by PNL at the FORSCOM Fort Stewart facility located approximately 25 miles southwest of Savannah, Georgia. It is a companion report to Volume 1, Executivemore » Summary, and Volume 2, Baseline Detail. The results of the analyses of EROs are presented in 11 common energy end-use categories (e.g., boilers and furnaces, service hot water, and building lighting). A narrative description of each ERO is provided, along with a table detailing information on the installed cost, energy and dollar savings; impacts on operations and maintenance (O&M); and, when applicable, a discussion of energy supply and demand, energy security, and environmental issues. A description of the evaluation methodologies and technical and cost assumptions is also provided for each ERO. Summary tables present the cost-effectiveness of energy end-use equipment before and after the implementation of each ERO. The tables also present the results of the life-cycle cost (LCC) analysis indicating the net present value (NPV) and savings to investment ratio (SIR) of each ERO.« less
Breda, Alberto; Territo, Angelo; Scoffone, Cesare; Seitz, Christian; Knoll, Thomas; Herrmann, Thomas; Brehmer, Mariannhe; Osther, Palle J S; Liatsikos, Evangelos
2017-11-12
Percutaneous nephrolithotomy (PNL) is the treatment of choice for larger and complex renal calculi. First step in performing PNL is to obtain access to the renal cavity using either fluoroscopy or ultrasound (US) guidance or a combination of both. Which guiding method to choose is controversial? A systematic review of the literature was performed comparing image guidance modalities for obtaining access in PNL. Evidence acquisition and synthesis: A PubMed, Scopus and Cochrane search for peer-reviewed studies was performed using the keywords "ultrasound" AND "fluoroscopy" AND "Percutaneous nephrolithotomy". Eligible articles were reviewed according to PRISMA criteria. Two hundred and forty records were identified using the keywords. Of these twelve studies were considered relevant. US guidance seems to be associated with a slightly lower complication rate, which may be related to fewer puncture attempts needed for obtaining access and to better peri-renal organ visualization. On the other hand, US-guidance alone needs the adjunct of fluoroscopy in a significant number of cases for achieving access. Stone free rate (SFR) was comparable between groups. Using US for renal access unequivocally reduces radiation exposure. Current evidence indicates that both fluoroscopy and US guidance may be successfully used for obtaining percutaneous renal access. Combining the image-guiding modalities - US and fluoroscopy - seems to increase outcome in PNL both with regard to success in achieving access and reducing complications. Furthermore, including US in the access strategy of PNL reduces radiation exposure to surgeon and staff as well as patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, J.F.
1989-06-01
This report summarizes progress on OHER biomedical and health-effects research conducted at PNL in FY 1988. The research develops the knowledge and scientific principles necessary to identify, understand, and anticipate the long-term health consequences of energy-related radiation and chemicals. Our continuing emphasis is to decrease the uncertainty of health-effects risk estimates from existing and/or developing energy-related technologies through an increased understanding of how radiation and chemicals cause health effects. The report is arranged to reflect PNL research relative to OHER programmatic structure. The first section, on human health effects, concerns statistical and epidemiological studies for assessing health risks. The nextmore » section, which contains reports of health-effects research in biological systems, includes research with radiation and chemicals.« less
Cracco, Cecilia Maria; Scoffone, Cesare Marco
2011-12-01
Percutaneous nephrolithotomy (PNL) is still the gold-standard treatment for large and/or complex renal stones. Evolution in the endoscopic instrumentation and innovation in the surgical skills improved its success rate and reduced perioperative morbidity. ECIRS (Endoscopic Combined IntraRenal Surgery) is a new way of affording PNL in a modified supine position, approaching antero-retrogradely to the renal cavities, and exploiting the full array of endourologic equipment. ECIRS summarizes the main issues recently debated about PNL. The recent literature regarding supine PNL and ECIRS has been reviewed, namely about patient positioning, synergy between operators, procedures, instrumentation, accessories and diagnostic tools, step-by-step standardization along with versatility of the surgical sequence, minimization of radiation exposure, broadening to particular and/or complex patients, limitation of post-operative renal damage. Supine PNL and ECIRS are not superior to prone PNL in terms of urological results, but guarantee undeniable anesthesiological and management advantages for both patient and operators. In particular, ECIRS requires from the surgeon a permanent mental attitude to synergy, standardized surgical steps, versatility and adherence to the ongoing clinical requirements. ECIRS can be performed also in particular cases, irrespective to age or body habitus. The use of flexible endoscopes during ECIRS contributes to minimizing radiation exposure, hemorrhagic risk and post-PNL renal damage. ECIRS may be considered an evolution of the PNL procedure. Its proposal has the merit of having triggered the critical analysis of the various PNL steps and of patient positioning, and of having transformed the old static PNL into an updated approach.
Hadj Sassi, Azza; Trigui-Lahiani, Hèla; Abdeljalil, Salma; Gargouri, Ali
2017-02-01
Pectin lyase (pnl) is the only pectinase able to hydrolyze directly the highly methylated pectin without liberating the toxic methanol and without disturbing ester content responsible for specific aroma of juices. The cDNA of Penicillium occitanis pnl (mature form) was cloned into pET-21a as expression vector and over-expressed into Esherichia coli. Most of recombinant pnl was expressed as inclusion bodies. Pnl activity was confirmed by colorimetric assay. To enhance the solubility yield of the expressed pnl, the effects of induction temperature, host strain and expression level were optimized. Maximal production of functional pnl was obtained after induction by 0.4mM IPTG at 30°C and 150rpm for 16h. Interestingly, the use of Origami host strain, having an oxidized cytoplasm favoring disulfide bonds formation required for the active conformation of the enzyme, has significantly improved the yield of the soluble active form of recombinant pnl. This pnl was successfully purified through a single step purification using His-Trap affinity column chromatography. This work is the first to report pnl expression into Origami strain. Alternatively, the inclusion bodies were isolated, denatured by high concentration of urea and gradually refolded by successive dialysis, leading to their transformation into soluble and active form. Copyright © 2016 Elsevier B.V. All rights reserved.
Minimizing radiation exposure during percutaneous nephrolithotomy.
Chen, T T; Preminger, G M; Lipkin, M E
2015-12-01
Given the recent trends in growing per capita radiation dose from medical sources, there have been increasing concerns over patient radiation exposure. Patients with kidney stones undergoing percutaneous nephrolithotomy (PNL) are at particular risk for high radiation exposure. There exist several risk factors for increased radiation exposure during PNL which include high Body Mass Index, multiple access tracts, and increased stone burden. We herein review recent trends in radiation exposure, radiation exposure during PNL to both patients and urologists, and various approaches to reduce radiation exposure. We discuss incorporating the principles of As Low As reasonably Achievable (ALARA) into clinical practice and review imaging techniques such as ultrasound and air contrast to guide PNL access. Alternative surgical techniques and approaches to reducing radiation exposure, including retrograde intra-renal surgery, retrograde nephrostomy, endoscopic-guided PNL, and minimally invasive PNL, are also highlighted. It is important for urologists to be aware of these concepts and techniques when treating stone patients with PNL. The discussions outlined will assist urologists in providing patient counseling and high quality of care.
Qi, Shiyong; Li, Yanni; Liu, Xu; Zhang, Changwen; Zhang, Hongtuan; Zhang, Zhihong; Xu, Yong
2014-09-01
To evaluate the clinical efficacy, safety, and costs of percutaneous occlusive balloon catheter-assisted ureteroscopic lithotripsy (POBC-URSL) for large impacted proximal ureteral calculi. 156 patients with impacted proximal ureteral stones ≥1.5 cm in size were randomized to ureteroscopic lithotripsy (URSL), POBC-URSL, and percutaneous nephrolithotomy (PNL) group between May 2010 and May 2013. For URSL, the calculi were disintegrated with the assistance of anti-retropulsion devices. POBC-URSL was performed with the assistance of an 8F percutaneous occlusive balloon catheter. PNL was finished with the combination of an ultrasonic and a pneumatic lithotripter. A flexible ureteroscope and a 200 μm laser fiber were used to achieve stone-free status to a large extent for each group. Variables studied were mean operative time, auxiliary procedure, postoperative hospital stay, operation-related complications, stone clearance rate, and treatment costs. The mean lithotripsy time for POBC-URSL was shorter than URSL, but longer than PNL (42.6±8.9 minutes vs 66.7±15.3 minutes vs 28.1±6.3 minutes, p=0.014). The auxiliary procedure rate and postoperative fever rate for POBC-URSL were significantly lower than URSL and comparable to PNL (p<0.01, p=0.034). POBC-URSL was superior to URSL with regard to the stone clearance rate at 3 days postoperatively, and as good as PNL (98.1% vs 75.0% vs 96.2%, p<0.01). The postoperative hospital stay and hematuria rate were lower in POBC-URSL group than PNL group and similar to URSL group (p=0.016, p<0.01). The treatment costs were lowest in POBC-URSL group ($1205.0±$113.9 vs $1731.7±$208.1 vs $2446.4±$166.4, p=0.004). For large impacted proximal ureteral calculi, POBC-URSL was associated with a higher stone clearance rate, fewer complications and costs. POBC-URSL combined the advantages of URSL and PNL.
Soylemez, Haluk; Penbegül, Necmettin; Utangac, Mehmet Mazhar; Dede, Onur; Çakmakçı, Süleyman; Hatipoglu, Namık Kemal
2016-08-01
Pelvic kidney stones remain a unique challenge to the endourologists. Treatment options include open surgery, extracorporeal shockwave lithotripsy, percutaneous nephrolithotomy (PNL), retrograde intrarenal surgery, and laparoscopy assisted PNL (LA-PNL). As a minimal invasive option, LA-PNL can decrease the risk for bowel and major vessel injury. Here, we describe our experience using the LA-PNL procedures with different combinations, to treat kidney stones in multiple patients with a pelvic ectopic kidney (PEK). Eight patients, with PEK, kidney stones, and no other treatment choice, but open surgery, were included in the study. Two different laparoscopic techniques such as mesocolon dissection and transmesocolic, and four different percutaneous procedures such as standard-PNL, mini-PNL, micro-PNL, and a PNL through the renal pelvis were used for stone extraction in these patients. The mean age of patients was 25.6 ± 12.9 years and mean stone size was 524.1 ± 430.3 mm(2). Mean operation time was 150.5 ± 40.0 (77-210) min which was composed of retrograde catheterization (14.8 ± 2.9 min), laparoscopic procedure (48.7 ± 20.6 min) and PNL procedure (86.8 ± 31.1 min). Residual stones were seen in two patients (no additional treatment was need), while a 'stone-free' procedure was achieved in six patients (75.0 %). On the post-operative first month visit, a stone was observed on radiological examinations in only one patient (87.5 % stone-free). Mean hospitalization time was 2.8 ± 0.9 days. No perioperative or post-operative complication was observed in all patients. LA-PNL surgery is a safe and effective option for treatment of PEK stones, and has several alternative approaches.
Neal-McKinney, Jason M.; Liu, Kun C.; Jinneman, Karen C.; Wu, Wen-Hsin; Rice, Daniel H.
2018-01-01
Campylobacter jejuni causes more than 2 million cases of gastroenteritis annually in the United States, and is also linked to the autoimmune sequelae Guillan–Barre syndrome (GBS). GBS often results in flaccid paralysis, as the myelin sheaths of nerve cells are degraded by the adaptive immune response. Certain strains of C. jejuni modify their lipooligosaccharide (LOS) with the addition of neuraminic acid, resulting in LOS moieties that are structurally similar to gangliosides present on nerve cells. This can trigger GBS in a susceptible host, as antibodies generated against C. jejuni can cross-react with gangliosides, leading to demyelination of nerves and a loss of signal transduction. The goal of this study was to develop a quantitative PCR (qPCR) method and use whole genome sequencing data to detect the Campylobacter sialyltransferase (cst) genes responsible for the addition of neuraminic acid to LOS. The qPCR method was used to screen a library of 89 C. jejuni field samples collected by the Food and Drug Administration Pacific Northwest Lab (PNL) as well as clinical isolates transferred to PNL. In silico analysis was used to screen 827 C. jejuni genomes in the FDA GenomeTrakr SRA database. The results indicate that a majority of C. jejuni strains could produce LOS with ganglioside mimicry, as 43.8% of PNL isolates and 46.9% of the GenomeTrakr isolates lacked the cst genes. The methods described in this study can be used by public health laboratories to rapidly determine whether a C. jejuni isolate has the potential to induce GBS. Based on these results, a majority of C. jejuni in the PNL collection and submitted to GenomeTrakr have the potential to produce LOS that mimics human gangliosides. PMID:29615986
Neal-McKinney, Jason M; Liu, Kun C; Jinneman, Karen C; Wu, Wen-Hsin; Rice, Daniel H
2018-01-01
Campylobacter jejuni causes more than 2 million cases of gastroenteritis annually in the United States, and is also linked to the autoimmune sequelae Guillan-Barre syndrome (GBS). GBS often results in flaccid paralysis, as the myelin sheaths of nerve cells are degraded by the adaptive immune response. Certain strains of C. jejuni modify their lipooligosaccharide (LOS) with the addition of neuraminic acid, resulting in LOS moieties that are structurally similar to gangliosides present on nerve cells. This can trigger GBS in a susceptible host, as antibodies generated against C. jejuni can cross-react with gangliosides, leading to demyelination of nerves and a loss of signal transduction. The goal of this study was to develop a quantitative PCR (qPCR) method and use whole genome sequencing data to detect the Campylobacter sialyltransferase ( cst ) genes responsible for the addition of neuraminic acid to LOS. The qPCR method was used to screen a library of 89 C. jejuni field samples collected by the Food and Drug Administration Pacific Northwest Lab (PNL) as well as clinical isolates transferred to PNL. In silico analysis was used to screen 827 C. jejuni genomes in the FDA GenomeTrakr SRA database. The results indicate that a majority of C. jejuni strains could produce LOS with ganglioside mimicry, as 43.8% of PNL isolates and 46.9% of the GenomeTrakr isolates lacked the cst genes. The methods described in this study can be used by public health laboratories to rapidly determine whether a C. jejuni isolate has the potential to induce GBS. Based on these results, a majority of C. jejuni in the PNL collection and submitted to GenomeTrakr have the potential to produce LOS that mimics human gangliosides.
Development and Use of a Virtual NMR Facility
NASA Astrophysics Data System (ADS)
Keating, Kelly A.; Myers, James D.; Pelton, Jeffrey G.; Bair, Raymond A.; Wemmer, David E.; Ellis, Paul D.
2000-03-01
We have developed a "virtual NMR facility" (VNMRF) to enhance access to the NMR spectrometers in Pacific Northwest National Laboratory's Environmental Molecular Sciences Laboratory (EMSL). We use the term virtual facility to describe a real NMR facility made accessible via the Internet. The VNMRF combines secure remote operation of the EMSL's NMR spectrometers over the Internet with real-time videoconferencing, remotely controlled laboratory cameras, real-time computer display sharing, a Web-based electronic laboratory notebook, and other capabilities. Remote VNMRF users can see and converse with EMSL researchers, directly and securely control the EMSL spectrometers, and collaboratively analyze results. A customized Electronic Laboratory Notebook allows interactive Web-based access to group notes, experimental parameters, proposed molecular structures, and other aspects of a research project. This paper describes our experience developing a VNMRF and details the specific capabilities available through the EMSL VNMRF. We show how the VNMRF has evolved during a test project and present an evaluation of its impact in the EMSL and its potential as a model for other scientific facilities. All Collaboratory software used in the VNMRF is freely available from http://www.emsl.pnl.gov:2080/docs/collab.
De, Abhishek; Hasanoor Reja, Abu Hena; Aggarwal, Ishad; Sen, Sumit; Sil, Amrita; Bhattacharya, Basudev; Sharma, Nidhi; Ansari, Asad; Sarda, Aarti; Chatterjee, Gobinda; Das, Sudip
2017-01-01
Background: Pure neural leprosy (PNL) still remains a diagnostic challenge because of the absence of sine qua non skin lesions of leprosy and a confirmatory diagnostic method. The authors had earlier described a simple yet objective technique of combining fine needle aspiration cytology (FNAC) coupled with a multiplex polymerase chain reaction (PCR) in a pilot study, wherein the technique showed promise of a reliable diagnostic tool. In the pursuit of further evidence, the authors carried out a 4-year study with PNL cases to find the efficacy and reliability of the said method in a larger sample size. Aim: This study was conducted to find the efficacy, reliability, and reproducibility of FNAC coupled with multiplex PCR and Ziehl-Neelsen (ZN) staining in identifying the cases of PNL. Materials and Methods: All cases that were suspected to be suffering from PNL, following evaluation by two independent observers were included in the study and were subjected to FNAC from the affected nerve, and the aspirates were evaluated for cytology, ZN staining, and multiplex PCR for Mycobacterium leprae genome. In addition, serum anti-PGL1 levels were also performed in all the study subjects. Fifteen non-PNL cases were also included in the control arm. Results: A total of 47 cases were included in the test arm and subjected to FNAC. Conventional ZN staining could demonstrate acid-fast bacilli (AFB) in only 15 out of 47 cases (31.91%) while M. leprae DNA could be elicited in 37 (78.72%) cases by the multiplex PCR. Only 13 (27.65%) out of 47 cases showed anti-PGLI-1 antibody positivity. On cytological examination of the nerve aspirates, only 11 (23.40%) cases showed epithelioid cells whereas nonspecific inflammation was seen in 26 (75.60%) cases. Conclusion: The results of this study conducted over a larger sample size corroborate with the findings of our pilot study. In a resource poor set up, FNAC in combination with ZN staining and multiplex PCR is a rapid, simple, and easily performed test, which can give a reproducible and objective diagnosis in cases of PNL. PMID:29263539
Mehmet, Rifaioglu Murat; Rustu, Yalcinkaya Fatih; Hanefi, Bayarogullari; Mursel, Davarci; Fusun, Aydogan; Mehmet, Inci
2013-01-01
Percutaneous nephrolithotomy (PNL) is an effective procedure for the treatment of patients with large or complex stones. PNL is challenging in anomalous kidneys, certain patients, such as those with renal ectopia. It is unable to undergo PNL in conventional technique safely in these cases. We presented a case report of laparoscopic-assisted PNL via direct pelvic puncture in a pelvic kidney stone and discussed previous published literature. A 49-year-old man presented with right lower quadrant pain and hematuria. Intravenous pyelography and three-dimensional computerized tomography revealed an opaque 2.7 × 1.7 cm pelvis renalis stone in a right side ectopic pelvic kidney with grade III hydronephrosis. Laparoscopic-assisted tubeless PNL was performed to remove the calculus. Laparoscopic-assisted PNL as a minimally invasive therapy in ectopic kidney has many advantages. Our case showed that, in pelvic ectopic kidney with pelvic stones greater than 1.5 cm in size, laparoscopic-assisted PNL via direct pelvis puncture is a safe and effective technique.
Spuur, Kelly; Webb, Jodi; Poulos, Ann; Nielsen, Sharon; Robinson, Wayne
2018-03-01
The aim of this study is to determine the clinical rates of the demonstration of the inframammary angle (IMA) on the mediolateral oblique (MLO) view of the breast on digital mammograms and to compare the outcomes with current accreditation standards for compliance. Relationships between the IMA, age, the posterior nipple line (PNL) and compressed breast thickness will be identified and the study outcomes validated using appropriate analyses of inter-reader and inter-rater reliability and variability. Differences in left versus right data were also investigated. A quantitative retrospective study of 2270 randomly selected paired digital mammograms performed by BreastScreen NSW was undertaken. Data was collected by direct measurement and visual analysis. Intra-class correlation analyses were used to evaluate inter- and intra-rater reliability. The IMA was demonstrated on 52.4% of individual and 42.6% of paired mammograms. A linear relationship was found between the posterior nipple line (PNL) and age (p-value <0.001). The PNL was predicted to increase by 0.48 mm for every one year increment in age. The odds of demonstrating the IMA reduced by 2% for every one year increase in age (p-value = 0.001); are 0.4% higher for every 1 mm increase in PNL (p-value = 0.001) and 1.6% lower for every 1 mm increase in compressed breast thickness, (p-value<0.001). There was high inter- and intra-rater reliability for the PNL while there was 100% agreement for the demonstration of the IMA. Analysis of the demonstration of the IMA indicates clinically achievable rates (42.6%) well below that required for compliance (50%-75%) to known worldwide accreditation standards for screening mammography. These standards should be aligned to the reported evidence base. Visualisation of the IMA is impacted negatively by increasing age and compressed breast thickness but positively by breast size (PNL). Copyright © 2018 Elsevier B.V. All rights reserved.
Donaldson, James F; Lardas, Michael; Scrimgeour, Duncan; Stewart, Fiona; MacLennan, Steven; Lam, Thomas B L; McClinton, Samuel
2015-04-01
The prevalence of urolithiasis is increasing. Lower-pole stones (LPS) are the most common renal calculi and the most likely to require treatment. A systematic review comparing shock wave lithotripsy (SWL), retrograde intrarenal surgery (RIRS), and percutaneous nephrolithotomy (PNL) in the treatment of ≤20 mm LPS in adults was performed. Comprehensive searches revealed 2741 records; 7 randomised controlled trials (RCTs) recruiting 691 patients were included. Meta-analyses for stone-free rate (SFR) at ≤3 mo favoured PNL over SWL (risk ratio [RR]: 2.04; 95% confidence interval [CI], 1.50-2.77) and RIRS over SWL (RR: 1.31; 95% CI, 1.08-1.59). Stone size subgroup analyses revealed PNL and RIRS were considerably more effective than SWL for >10 mm stones, but the magnitude of benefit was markedly less for ≤10 mm stones. The quality of evidence (Grading of Recommendations Assessment, Development, and Evaluation [GRADE]) for SFR was moderate for these comparisons. The median SFR from reported RCTs suggests PNL is more effective than RIRS. The findings regarding other outcomes were inconclusive because of limited and inconsistent data. Well-designed, prospective, comparative studies that measure these outcomes using standardised definitions are required, particularly for the direct comparison of PNL and RIRS. This systematic review, which used Cochrane methodology and GRADE quality-of-evidence assessment, provides the first level 1a evidence for the management of LPS. We thoroughly examined the literature to compare the benefits and harms of the different ways of treating kidney stones located at the lower pole. PNL and RIRS were superior to SWL in clearing the stones within 3 mo, but we were unable to make any conclusions regarding other outcomes. More data is required from reliable studies before firm recommendations can be made. Copyright © 2014 European Association of Urology. Published by Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heubach, J.G.; Hunt, S.T.; Pond, L.R.
1992-06-01
Information management technology has proliferated in the past decade in response to the information explosion. As documentation accumulates, the need to access information residing in manuals, handbooks and regulations conveniently, accurately, and quickly has increased. However, studies show that only fractions of the available information is read (Martin, 1978). Consequently, one of the biggest challenges in linking information and electronic management of information is to use the power of communication technology to meet the information needs of the audience. Pacific Northwest Laboratories` (PNL) investigation of translating its print manual system to an on-line system fits this challenge precisely. PNL`s manualsmore » contain a tremendous amount of information for which manual holders are responsible. To perform their tasks in compliance with policy and procedure guidelines, users need to access information accurately, conveniently, and quickly. In order to select and use information management tools wisely, answers must be sought to a few basic questions. Communication experts cite four key questions: What do users want? What do users need? What characteristics of an on-line information system affect its usefulness? Who are the users whose wants and needs are to be met? Once these questions are answered, attention can be focused on finding the best match between user requirements and technology characteristics and weighing the costs and benefits of proposed options.« less
Adanur, Şenol; Ziypak, Tevfik; Sancaktutar, Ahmet Ali; Tepeler, Abdülkadir; Reşorlu, Berkan; Söylemez, Haluk; Dağgülli, Mansur; Özbey, İsa; Unsal, Ali
2014-02-01
We aimed to evaluate the effectiveness of percutaneous nephrolithotomy (PNL), stone-free rates, and related complications in children with radiolucent renal stones. A total of 56 patients aged <16 years from four institutions were enrolled in our study. Asymptomatic, clinically insignificant residual fragments measuring <4 mm or a complete stone-free status was accepted as the criterion for clinical success. Complications were evaluated according to the modified Clavien classification. The mean age of the patients was 7.8 ± 4.5 years. The mean stone size was calculated as 24.07 ± 10.4 mm. The median operative and fluoroscopy times were 53.2 min (15-170 min) and 172.4 s (5-520 s), respectively. The success rate after PNL monotherapy was 87.4%; the total success rate with shock wave lithotripsy used as an auxillary treatment method was detected as 94.6%. The total complication rate was 19.6% (11 patients). No adjacent organ injury was observed. All of the complications that occurred were minor according to the Clavien classification (Clavien Grades I-II). PNL can be applied to radiolucent pediatric renal stones in children with similar success, and complication rates as noted for radiopaque stones.
Qi, Shi-yong; Zhang, Zhi-hong; Zhang, Chang-wen; Liu, Ran-lu; Shi, Qi-duo; Xu, Yong
2013-12-01
To investigate the impact of staghorn stone branch number on outcomes of percutaneous nephrolithotomy (PNL). From January 2009 to January 2013, the 371 patients with staghorn stones who were referred to our hospital for PNL were considered for this study. All calculi were showed with CT 3-dimentional reconstruction (3-DR) imaging. The computerized database of the patients had been reviewed. Our exclusion criterion was patients with congenital renal anomalies, such as horse-shoe and ectopic kidneys. And borderline stones that branched to one major calyx only were also not included. From 3-DR images, the number of stone branching into minor renal calices was recorded. We made "3" as the branch breakdown between groups. And the patients were divided into four groups. The number of percutaneous tract, operative time, staged PNL, intra-operative blood loss, complications, stone clearance rate, and postoperative hospital day were compared. The 371 patients (386 renal units) underwent PNL successfully, included 144 single-tract PNL, 242 multi-tract PNL, 97 staged PNL. The average operative time was (100 ± 50) minutes; the average intra-operative blood loss was (83 ± 67) ml. The stone clearance rate were 61.7% (3 days) and 79.5% (3 months). The postoperative hospital stay was (6.9 ± 3.4) days. A significantly higher ratio of multi-tract (χ(2) = 212.220, P < 0.01) and staged PNL (χ(2) = 49.679, P < 0.01), longer operative time (F = 4.652, P < 0.01) and postoperative hospital day (F = 2.067, P = 0.043) and lower rate of stone clearance (χ(2) = 10.691 and 47.369, P < 0.05) were found in PNL for calculi with stone branch number ≥ 5. There was no statistically meaningful difference among the 4 groups based on Clavien complication system (P = 0.460). The possibility of multi-tract and staged PNL, lower rate of stone clearance and longer postoperative hospital day increase for staghorn calculi with stone branch number more than 5.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1994-04-01
This 1993 Annual Report from Pacific Northwest Laboratory (PNL) to the US DOE describes research in environment and health conducted during fiscal year (FY) 1993. The report is divided into four parts, each in a separate volume. This part, Volume 2, covers Environmental Sciences. The research is directed toward developing a fundamental understanding of subsurface and terrestrial systems as a basis for both managing these critical resources and addressing environmental problems such as environmental restoration and global change. There are sections on Subsurface Science, Terrestrial Science, Technology Transfer, Interactions with Educational Institutions, and Laboratory Directed Research and Development.
Singh, Vishwajeet; Sinha, Rahul Janak; Gupta, Dheeraj Kumar
2013-08-01
Nephrolithiasis has been reported in 20-28% of patients, of whom 50% are symptomatic for stone disease and 20% require definite urologic intervention. The management of nephrolithiasis includes oral alkali dissolution therapy, extracorporeal shock wave lithotripsy and surgical treatment. In such patients, percutaneous nephrolithotomy (PNL) as a method of stone treatment has been reported in few cases with limited experience. The aim of this study is to present our experience of PNL in autosomal dominant polycystic kidney disease (ADPKD) and assessing the outcome results. From 2002 to 2011, 22 patients (26 renal units) suffering from ADPKD with stone were managed by PNL. Demographic characteristics, operative parameters and postoperative complications were recorded and analysed. The overall success rate of PNL was 82.1% and PNL with extracorporeal shock wave lithotripsy for clinically significant residual fragments was 92.85% respectively. The hematuria required blood transfusion (n = 9), postoperative fever due to cyst infection (n = 4) and paralytic ileus (n = 3) were recorded. The PNL in ADPKD PNL is safe and effective but have more postoperative complications such as bleeding requiring transfusions, fever due to cyst infection and paralytic ileus.
Remote geologic structural analysis of Yucca Flat
NASA Astrophysics Data System (ADS)
Foley, M. G.; Heasler, P. G.; Hoover, K. A.; Rynes, N. J.; Thiessen, R. L.; Alfaro, J. L.
1991-12-01
The Remote Geologic Analysis (RGA) system was developed by Pacific Northwest Laboratory (PNL) to identify crustal structures that may affect seismic wave propagation from nuclear tests. Using automated methods, the RGA system identifies all valleys in a digital elevation model (DEM), fits three-dimensional vectors to valley bottoms, and catalogs all potential fracture or fault planes defined by coplanar pairs of valley vectors. The system generates a cluster hierarchy of planar features having greater-than-random density that may represent areas of anomalous topography manifesting structural control of erosional drainage development. Because RGA uses computer methods to identify zones of hypothesized control of topography, ground truth using a well-characterized test site was critical in our evaluation of RGA's characterization of inaccessible test sites for seismic verification studies. Therefore, we applied RGA to a study area centered on Yucca Flat at the Nevada Test Site (NTS) and compared our results with both mapped geology and geologic structures and with seismic yield-magnitude models. This is the final report of PNL's RGA development project for peer review within the U.S. Department of Energy Office of Arms Control (OAC) seismic-verification community. In this report, we discuss the Yucca Flat study area, the analytical basis of the RGA system and its application to Yucca Flat, the results of the analysis, and the relation of the analytical results to known topography, geology, and geologic structures.
Jung, Gyoo Hwan; Jung, Jae Hyun; Ahn, Tae Sik; Lee, Joong Sub; Cho, Sung Yong; Jeong, Chang Wook; Lee, Seung Bae; Kim, Hyeon Hoe; Oh, Seung-June
2015-07-01
To investigate surgical outcomes between retrograde intrarenal surgery (RIRS) and percutaneous nephrolithotomy (PNL) groups for a main stone sized 15 to 30 mm and located in the lower-pole calyx. Patients who underwent PNL or RIRS for a main stone sized 15 to 30 mm and located in the lower-pole calyx were retrospectively reviewed. Each patient in the RIRS group was matched to one in the PNL group on the basis of calculated propensity scores by use of age, sex, body mass index, previous treatment history, stone site, maximum stone size, and stone volume. We compared perioperative outcomes between the unmatched and matched groups. Patients underwent PNL (n=87, 66.4%) or RIRS (n=44, 33.6%). After matching, 44 patients in each group were included. Mean patient age was 54.4 ± 13.7 years. Perioperative hemoglobin drop was significantly higher and the hospital stay was longer in the PNL group than in the RIRS group. The operative time was significantly longer in the RIRS group than in the PNL group. Stone-free rates were higher and complications rates were lower in the RIRS group than in the PNL group without statistical significance. The presence of a stone located in the lower-anterior minor calyx was a predictor of stone-free status. RIRS and single-session PNL for patients with a main stone of 15 to 30 mm located in the lower-pole calyx showed comparable surgical results. However, RIRS can be performed more safely than PNL with less bleeding. Stones in the lower-anterior minor calyx should be carefully removed during these procedures.
Jung, Gyoo Hwan; Jung, Jae Hyun; Ahn, Tae Sik; Lee, Joong Sub; Cho, Sung Yong; Jeong, Chang Wook; Lee, Seung Bae; Kim, Hyeon Hoe
2015-01-01
Purpose To investigate surgical outcomes between retrograde intrarenal surgery (RIRS) and percutaneous nephrolithotomy (PNL) groups for a main stone sized 15 to 30 mm and located in the lower-pole calyx. Materials and Methods Patients who underwent PNL or RIRS for a main stone sized 15 to 30 mm and located in the lower-pole calyx were retrospectively reviewed. Each patient in the RIRS group was matched to one in the PNL group on the basis of calculated propensity scores by use of age, sex, body mass index, previous treatment history, stone site, maximum stone size, and stone volume. We compared perioperative outcomes between the unmatched and matched groups. Results Patients underwent PNL (n=87, 66.4%) or RIRS (n=44, 33.6%). After matching, 44 patients in each group were included. Mean patient age was 54.4±13.7 years. Perioperative hemoglobin drop was significantly higher and the hospital stay was longer in the PNL group than in the RIRS group. The operative time was significantly longer in the RIRS group than in the PNL group. Stone-free rates were higher and complications rates were lower in the RIRS group than in the PNL group without statistical significance. The presence of a stone located in the lower-anterior minor calyx was a predictor of stone-free status. Conclusions RIRS and single-session PNL for patients with a main stone of 15 to 30 mm located in the lower-pole calyx showed comparable surgical results. However, RIRS can be performed more safely than PNL with less bleeding. Stones in the lower-anterior minor calyx should be carefully removed during these procedures. PMID:26175872
Hemostasis in tubeless PNL: point of technique.
Aron, Monish; Goel, Rajiv; Kesarwani, Pawan K; Gupta, Narmada P
2004-01-01
Tubeless PNL (percutaneous nephrolithotomy), in a highly selected group of patients, is a modification aimed at reducing the morbidity of PNL. We present a simple technique of achieving tract hemostasis as an adjunct to the safe performance of a tubeless PNL. Charts of 40 consecutive patients who underwent tubeless PNL at our center were reviewed. In the latter 20 consecutive patients, diathermy coagulation of the intrarenal bleeders and tract was done and these patients were compared with the earlier 20 patients in whom fulguration was not done. Drop in hemoglobin, postoperative analgesic requirement, operating time, length of hospitalization and postoperative complications were compared. No statistical difference was found between the operative times and drop in hemoglobin for both the groups. The length of hospitalization and postoperative analgesic requirement were significantly less in the fulguration group. No significant complications were noted in either of the two groups. Fulguration of visible intrarenal and tract bleeders is a simple, safe and effective hemostatic adjunct in patients undergoing tubeless PNL. copyright 2004 S. Karger AG, Basel
Variety of neutron sensors based on scintillating glass waveguides
NASA Astrophysics Data System (ADS)
Bliss, Mary; Craig, Richard A.
1995-04-01
Pacific Northwest Laboratory (PNL) has fabricated cerium-activated lithium silicate glass scintillating fiber waveguide neutron sensors via a hot-downdraw process. These fibers typically have a transmission length (e-1 length) of greater than 2 meters. The underlying physics of, the properties of, and selected devices incorporating these fibers are described. These fibers constitute an enabling technology for a wide variety of neutron sensors.
NASA Astrophysics Data System (ADS)
Ren, Yefei; Wen, Ruizhi; Yao, Xinxin; Ji, Kun
2017-08-01
The consideration of soil nonlinearity is important for the accurate estimation of the site response. To evaluate the soil nonlinearity during the 2008 Ms8.0 Wenchuan Earthquake, 33 strong-motion records obtained from the main shock and 890 records from 157 aftershocks were collected for this study. The horizontal-to-vertical spectral ratio (HVSR) method was used to calculate five parameters: the ratio of predominant frequency (RFp), degree of nonlinearity (DNL), absolute degree of nonlinearity (ADNL), frequency of nonlinearity (fNL), and percentage of nonlinearity (PNL). The purpose of this study was to evaluate the soil nonlinearity level of 33 strong-motion stations and to investigate the characteristics, performance, and effective usage of these five parameters. Their correlations with the peak ground acceleration (PGA), peak ground velocity (PGV), average uppermost 30-m shear-wave velocity ( V S30), and maximum amplitude of HVSR ( A max) were investigated. The results showed that all five parameters correlate well with PGA and PGV. The DNL, ADNL, and PNL also show a good correlation with A max, which means that the degree of soil nonlinearity not only depends on the ground-motion amplitude (e.g., PGA and PGV) but also on the site condition. The fNL correlates with PGA and PGV but shows no correlation with either A max or V S30, implying that the frequency width affected by the soil nonlinearity predominantly depends on the ground-motion amplitude rather than the site condition. At 16 of the 33 stations analyzed in this study, the site response showed evident (i.e., strong and medium) nonlinearity during the main shock of the Wenchuan Earthquake, where the ground-motion level was almost beyond the threshold of PGA > 200 cm/s2 or PGV > 15 cm/s. The site response showed weak and no nonlinearity at the other 14 and 3 stations. These results also confirm that RFp, DNL, ADNL, and PNL are effective in identifying the soil nonlinearity behavior. The identification results vary for different parameters because each parameter has individual features. The performance of the PNL was better than that of DNL and ADNL in this case study. The thresholds of ADNL and PNL are proposed to be 2.0 and 7%, respectively.[Figure not available: see fulltext.
Cherniakov, Irina; Izgelov, Dvora; Domb, Abraham J; Hoffman, Amnon
2017-11-15
The lipophilic phytocannabinoids cannabidiol (CBD) and Δ 9 -tetrahydrocannabinol (THC) show therapeutic efficacy in various medical conditions. Both molecules are poorly water soluble and subjected to extensive first pass metabolism in the gastrointestinal tract, leading to a limited oral bioavailability of approximately 9%. We have developed an advanced lipid based Self-Emulsifying Drug Delivery System termed Advanced Pro-NanoLiposphere (PNL) pre-concentrate. The PNL is composed of lipid and emulsifying excipients of GRAS status and are known to increase solubility and reduce Phase I metabolism of lipophilic active compounds. Advanced PNLs are PNLs with an incorporated natural absorption enhancers. These molecules are natural alkaloids and phenolic compounds which were reported to inhibit certain phase I and phase II metabolism processes. Here we use piperine, curcumin and resveratrol to formulate the Advanced-PNL formulations. Consequently, we have explored the utility of these Advanced-PNLs on CBD and THC oral bioavailability. Oral administration of CBD-piperine-PNL resulted in 6-fold increase in AUC compared to CBD solution, proving to be the most effective of the screened formulations. The same trend was found in pharmacokinetic experiments of THC-piperine-PNL which resulted in a 9.3-fold increase in AUC as compared to THC solution. Our Piperine-PNL can be used as a platform for synchronized delivery of piperine and CBD or THC to the enterocyte site. This co-localization provides an increase in CBD and THC bioavailability by its effect at the pre-enterocyte and the enterocyte levels of the absorption process. The extra augmentation in the absorption of CBD and THC by incorporating piperine into PNL is attributed to the inhibition of Phase I and phase II metabolism by piperine in addition to the Phase I metabolism and P-gp inhibition by PNL. These novel results pave the way to utilize piperine-PNL delivery system for other poorly soluble, highly metabolized compounds that currently cannot be administered orally. Copyright © 2017. Published by Elsevier B.V.
Is Tubeless Percutaneous Nephrolithotomy a Feasible Technique for the Treatment of Staghorn Calculi?
Lee, Sang Cheol; Kim, Chang Hee; Kim, Kwang Taek; Kim, Tae Beom; Kim, Khae Hawn; Jung, Han; Yoon, Sang Jin
2013-01-01
Purpose Tubeless percutaneous nephrolithotomy (PNL) remains a challenging technique for the surgical treatment of staghorn renal calculi. Our study was designed to compare surgical outcomes between conventional and tubeless PNL. Materials and Methods We retrospectively enrolled consecutive patients who underwent conventional or tubeless PNL under general anesthesia performed by a single surgeon (H.J.) for the treatment of staghorn calculi between 2003 and 2012. All patients were divided into two groups: group 1 included patients who underwent conventional PNL and group 2 included patients who were managed by tubeless PNL for the treatment of staghorn calculi. Preoperative and postoperative parameters were analyzed between the two groups, including age, stone burden, complications, any interventions, and duration of hospital stay. Results A total of 165 patients (group 1, 106; group 2, 59) were enrolled in the study. No significant differences in age, sex, body mass index, or stone laterality were observed between the two groups. The mean stone burdens (±standard deviation) of group 1 and group 2 were 633.6 (±667.4) and 529.9 (±362.8), respectively (p=0.271). The postoperative stone-free clearance rate was higher in group 2 (78.0%) than in group 1 (69.8%); however, the difference was not clinically significant (p=0.127). In addition, no significant differences in postoperative complications, including fever, bleeding, infection, or additional interventions, were observed between the two groups. Conclusions Our results demonstrated that tubeless PNL has the same effectiveness and safety as conventional PNL in the treatment of staghorn calculi. Tubeless PNL may be feasible for managing renal staghorn calculi. PMID:24175044
Is tubeless percutaneous nephrolithotomy a feasible technique for the treatment of staghorn calculi?
Lee, Sang Cheol; Kim, Chang Hee; Kim, Kwang Taek; Kim, Tae Beom; Kim, Khae Hawn; Jung, Han; Yoon, Sang Jin; Oh, Jin Kyu
2013-10-01
Tubeless percutaneous nephrolithotomy (PNL) remains a challenging technique for the surgical treatment of staghorn renal calculi. Our study was designed to compare surgical outcomes between conventional and tubeless PNL. We retrospectively enrolled consecutive patients who underwent conventional or tubeless PNL under general anesthesia performed by a single surgeon (H.J.) for the treatment of staghorn calculi between 2003 and 2012. All patients were divided into two groups: group 1 included patients who underwent conventional PNL and group 2 included patients who were managed by tubeless PNL for the treatment of staghorn calculi. Preoperative and postoperative parameters were analyzed between the two groups, including age, stone burden, complications, any interventions, and duration of hospital stay. A total of 165 patients (group 1, 106; group 2, 59) were enrolled in the study. No significant differences in age, sex, body mass index, or stone laterality were observed between the two groups. The mean stone burdens (±standard deviation) of group 1 and group 2 were 633.6 (±667.4) and 529.9 (±362.8), respectively (p=0.271). The postoperative stone-free clearance rate was higher in group 2 (78.0%) than in group 1 (69.8%); however, the difference was not clinically significant (p=0.127). In addition, no significant differences in postoperative complications, including fever, bleeding, infection, or additional interventions, were observed between the two groups. Our results demonstrated that tubeless PNL has the same effectiveness and safety as conventional PNL in the treatment of staghorn calculi. Tubeless PNL may be feasible for managing renal staghorn calculi.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bieda, J.; Bardel, J.; Pierce, B.
1995-12-31
Since 1992 Brookhaven National Laboratory (BNL) and Pacific Northwest Laboratory (PNL), acting on behalf of the U.S. Department of Energy, executed the first stage of the Cracow Program of Energy Conservation and Clean Fossil Fuels, called also American-Polish Program of Actions for Elimination of Low Emission Sources in Cracow. The main contractor for BNL and PNL was the Cracow Development Office (BRK). The interest in improving the condition of Cracow air results from the fact that the standard for permissible air pollution was exceeded several times in Cracow and especially within the central part of the town. Therefore, air pollutionmore » appeared one of the most important problems that faced the municipal authorities. It followed from monitoring investigations that the high level of air pollutant concentration is caused by in-home coal-fired tile stoves operated in winter seasons and by coal- and coke-fired boiler houses simulated mainly in the central part of the town. The results obtained in first stage are presented. This paper is an attempt to formulate conclusions drawn from these works and recommendations with regard to the future policy of the town authorities; selected results are presented to clarify or illustrate the conclusions.« less
Report on data requirements and hardware selection for in-situ ball viscometer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shepard, C.L.
1994-12-01
The in-situ ball rheometer is designed to provide data concerning the rheological properties of the waste contained in tank 101-SY. It is imperative that the data collected and the results obtained are useful to the community presently concerned with the mitigation of the waste contained within this tank. To ensure that this objective is met, discussions were held with representatives of different groups in order to determine their data needs. This report is a synopsis of these discussions. Four separate groups were identified as potential users of the data. Persons contacted included Don Trent (Pacific Northwest Laboratory (PNL)), who ismore » involved with Tempest modeling of the tank; Randy Marlow and John Strehlow (Westinghouse Hanford Company (WHC)), involved with structural analysis of the tank; Kemal Pasamehmetoglu and Cetin Unal (Los Alamos National Laboratory (LANL)), who are concerned with the safety analysis of activities performed within the tank; and Judith Bamberger, Paul Scott, and Gita Golcar (PNL) who are involved with the eventual retrieval of waste from the tank. Very specific questions were asked of these groups, including: From where in the tank are data needed? When should data be collected? In what manner are the data useful? What is the required accuracy of the data? Responses from each group are given.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olson, N.J.; Meier, T.E.
1995-04-01
Staff exchanges, such as the one described in this report, are intended to facilitate communication and collaboration among scientists and engineers at DOE laboratories, in US industry, and academia. During the past 5 years, PNL has developed prototype instrumentation to automate the data collection required for electrochemical determination of corrosion rates and behavior of materials in various electrically conductive environments. The last version is labeled the Sentry 100 prototype corrosion data scanner. Applications include these in the pulp and paper industry and at hazardous waste sites.
Dede, Onur; Sancaktutar, Ahmet Ali; Dağguli, Mansur; Utangaç, Mazhar; Baş, Okan; Penbegul, Necmettin
2015-10-01
The management of urolithiasis in children differs from adults because of anatomic and metabolic abnormalities. At present, various minimally invasive and invasive treatment strategies have been recommended to treat urinary tract Stones, including shock wave lithotripsy (SWL), standard percutaneous nephrolithotomy (PNL), mini-PNL, retrograde intrarenal surgery (RIRS), micro-PNL, and a new technique termed ultra-mini PNL (UMP). UMP is a new method for the treatment of kidney stones. The main difference between UMP and standard PNL or mini-PNL lies in the small access sheath and in its design. A 9.5F pediatric compact cystoscope was used (Figure). A major advantage of UMP is that it provides similar stone-free rates when compared with standard PNL, with lower intrarenal pressure than micro-PNL. The aim of the study was to determine the applicability and safety of UMP in the treatment of pediatric kidney stones. We retrospectively reviewed the files of 39 kidney stones in children who had undergone UMP between May 2011 and October 2014. The indications for UMP included stones resistant to SWL, stones requiring repeated sessions of SWL, and stones size larger than 20 mm. The study included 17 females and 22 males, with a mean age of 5.8 ± 4.6 years. The mean hemoglobin loss was 0.9 ± 0.6 mg/dL and none of the patients required a blood transfusion. The complication rate of the PNL procedure was 15.3% (n = 6). Complete clearance was achieved in 32 patients (82%) with UMP monotherapy, which increased to 34% (87.1%) 4 weeks after the operation. Management of urolithiasis necessitates a balance between stone clearance and morbidity related to the procedure. SWL often leads to persistent residual stones. The developing RIRS can minimize the risks associated with bleeding and visceral injury, but sometimes the abnormal pelvicaliceal anatomy and poor imaging of the flexible ureteroscopy may impact its success rate and applications. It has been reported that PNL can be performed safely and effectively to achieve a higher stone-free rate; however, it has serious complications such as bleeding that requires blood transfusion in 11-14% of the cases with increased risk of kidney loss. The recent development of smaller sheaths allows tract formation with minimal damage to the renal parenchyma, thereby reducing procedure-related morbidity without diminishing its therapeutic efficacy. The most important advantage of this surgical technique that has been developed is similar stone-free rates to standard PNL and lower intrarenal pressure than micro-PNL. Our experience supports that UMP is safe and effective for the management of renal stones in children. Copyright © 2015 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Liu, Fang; Ma, Ni; He, Chengwei; Hu, Yuanjia; Li, Peng; Chen, Meiwan; Su, Huanxing; Wan, Jian-Bo
2018-04-01
Panax notoginseng leaves (PNL) exhibit extensive activities, but few analytical methods have been established to exclusively determine the dammarane triterpene saponins in PNL. Ultra-performance liquid chromatography coupled with time-of-flight mass spectrometry (UPLC/Q-TOF MS) and HPLC-UV methods were developed for the qualitative and quantitative analysis of ginsenosides in PNL, respectively. Extraction conditions, including solvents and extraction methods, were optimized, which showed that ginsenosides Rc and Rb3, the main components of PNL, are transformed to notoginsenosides Fe and Fd, respectively, in the presence of water, by removing a glucose residue from position C-3 via possible enzymatic hydrolysis. A total of 57 saponins were identified in the methanolic extract of PNL by UPLC/Q-TOF MS. Among them, 19 components were unambiguously characterized by their reference substances. Additionally, seven saponins of PNL-ginsenosides Rb1, Rc, Rb2, and Rb3, and notoginsenosides Fc, Fe, and Fd-were quantified using the HPLC-UV method after extraction with methanol. The separation of analytes, particularly the separation of notoginsenoside Fc and ginsenoside Rc, was achieved on a Zorbax ODS C8 column at a temperature of 35°C. This developed HPLC-UV method provides an adequate linearity ( r 2 > 0.999), repeatability (relative standard deviation, RSD < 2.98%), and inter- and intraday variations (RSD < 4.40%) with recovery (98.7-106.1%) of seven saponins concerned. This validated method was also conducted to determine seven components in 10 batches of PNL. These findings are beneficial to the quality control of PNL and its relevant products.
Totally tubeless percutaneous nephrolithotomy is feasible in morbidly obese patients.
Aghamir, Seyed Mohammad Kazem; Mohseni, Mohammad Ghasem; Hosseini, Seyed Reza; Salavati, Alborz; Ganjali, Hossein; Fallah, Mohammad Ali; Rezaei, Hamed; Modaresi, Seyed Saeed
2017-06-01
Regarding technical difficulties that obese body habitus might impose to percutaneous nephrolithotomy (PNL) success and higher risk of peri-operative complications in this group of patients, we decided to retrospectively gather data from our patients during past 8 years to determine the stone free and complication rates. Between January 2007-December 2015, seventy-eight obese patients with body mass index over 35 who had indication for PNL including stones larger than 2 cm in pelvi-calyceal system or smaller extracorporeal shock wave lithotripsy (ESWL) resistant stones or who were not a fit candidate for ESWL due to increased skin to target distance, with no contraindication of PNL (including bleeding diathesis, inability to be positioned in prone) were enrolled. They were randomly assigned to group 1 (standard PNL with nephrostomy and ureteral stent) or group 2 (totally tubeless PNL with no ureteral stent and no nephrostomy). The outcomes were compared. The transfusion rate, operation time, and the hemoglobin drop were same across the groups (p>0.05). Total analgesic use was equivalent of 33.8 vs. 14.7 mgs of morphine sulfate (18-77 mg) and was significantly lower in total tubeless group (p=0.001). Return to normal activity was described as total number of in-patient and outpatient days from time of admission to the point which the patients returns to normal life activity such as going to job or school and was 19.4 vs. 9.3 days (6-30 days, p=0.001). Totally tubeless PNL in obese subjects would have lower analgesic use and return to normal activity versus standard PNL. Totally tubeless PNL is recommended for obese patients.
NASA Technical Reports Server (NTRS)
Brausch, J. F.
1972-01-01
An F106 aircraft with a J85-13 engine was used for static and flight acoustic and aerodynamic tests of a conical ejector, an unsuppressed annular plug, and three segmented suppressor nozzles. Static 100 ft. arc data, corrected for influences other than jet noise, were extrapolated to a 300 ft. sideline for comparison to 300 ft. altitude flyover data at M = 0.4. Data at engine speeds of 80 to 100% (max dry) static and 88 to 100% flight are presented. Flight velocity influence on noise is shown on peak OASPL and PNL, PNL directivity, EPNL and chosen spectra. Peak OASPL and PNL plus EPNL suppression levels are included showing slightly lower flight than static peak PNL suppression but greater EPNL than peak PNL suppression. Aerodynamic performance was as anticipated and closely matched model work for the 32-spoke nozzle.
The effects of previous open renal stone surgery types on PNL outcomes.
Ozgor, Faruk; Kucuktopcu, Onur; Ucpinar, Burak; Sarilar, Omer; Erbin, Akif; Yanaral, Fatih; Sahan, Murat; Binbay, Murat
2016-01-01
Our aim was to demonstrate the effect of insicion of renal parenchyma during open renal stone surgery (ORSS) on percutaneous nephrolithotomy (PNL) outcomes. Patients with history of ORSS who underwent PNL operation between June 2005 and June 2015 were analyzed retrospectively. Patients were divided into two groups according to their type of previous ORSS. Patients who had a history of ORSS with parenchymal insicion, such as radial nephrotomies, anatrophic nephrolithotomy, lower pole resection, and partial nephrectomy, were included in Group 1. Other patients with a history of open pyelolithotomy were enrolled in Group 2. Preoperative characteristics, perioperative data, stone-free status, and complications were compared between the groups. Stone-free status was defined as complete clearance of stone(s) or presence of residual fragments smaller than 4 mm. The retrospective nature of our study, different experience level of surgeons, and lack of the evaluation of anesthetic agents and cost of procedures were limitations of our study. 123 and 111 patients were enrolled in Groups 1 and 2, respectively. Preoperative characteristics were similar between groups. In Group 1, the mean operative time was statistically longer than in Group 2 (p=0.013). Stone-free status was significantly higher in Group 2 than in Group 1 (p=0.027). Complication rates were similar between groups. Hemorrhage requiring blood transfusion was the most common complication in both groups (10.5% vs. 9.9%). Our study demonstrated that a history of previous ORSS with parenchymal insicion significantly reduces the success rates of PNL procedure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheverton, R.D.; Dickson, T.L.; Merkle, J.G.
1992-03-01
The Yankee Atomic Electric Company has performed an Integrated Pressurized Thermal Shock (IPTS)-type evaluation of the Yankee Rowe reactor pressure vessel in accordance with the PTS Rule (10 CFR 50. 61) and a US Regulatory Guide 1.154. The Oak Ridge National Laboratory (ORNL) reviewed the YAEC document and performed an independent probabilistic fracture-mechnics analysis. The review included a comparison of the Pacific Northwest Laboratory (PNL) and the ORNL probabilistic fracture-mechanics codes (VISA-II and OCA-P, respectively). The review identified minor errors and one significant difference in philosophy. Also, the two codes have a few dissimilar peripheral features. Aside from these differences,more » VISA-II and OCA-P are very similar and with errors corrected and when adjusted for the difference in the treatment of fracture toughness distribution through the wall, yield essentially the same value of the conditional probability of failure. The ORNL independent evaluation indicated RT{sub NDT} values considerably greater than those corresponding to the PTS-Rule screening criteria and a frequency of failure substantially greater than that corresponding to the primary acceptance criterion'' in US Regulatory Guide 1.154. Time constraints, however, prevented as rigorous a treatment as the situation deserves. Thus, these results are very preliminary.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheverton, R.D.; Dickson, T.L.; Merkle, J.G.
1992-03-01
The Yankee Atomic Electric Company has performed an Integrated Pressurized Thermal Shock (IPTS)-type evaluation of the Yankee Rowe reactor pressure vessel in accordance with the PTS Rule (10 CFR 50. 61) and a US Regulatory Guide 1.154. The Oak Ridge National Laboratory (ORNL) reviewed the YAEC document and performed an independent probabilistic fracture-mechnics analysis. The review included a comparison of the Pacific Northwest Laboratory (PNL) and the ORNL probabilistic fracture-mechanics codes (VISA-II and OCA-P, respectively). The review identified minor errors and one significant difference in philosophy. Also, the two codes have a few dissimilar peripheral features. Aside from these differences,more » VISA-II and OCA-P are very similar and with errors corrected and when adjusted for the difference in the treatment of fracture toughness distribution through the wall, yield essentially the same value of the conditional probability of failure. The ORNL independent evaluation indicated RT{sub NDT} values considerably greater than those corresponding to the PTS-Rule screening criteria and a frequency of failure substantially greater than that corresponding to the ``primary acceptance criterion`` in US Regulatory Guide 1.154. Time constraints, however, prevented as rigorous a treatment as the situation deserves. Thus, these results are very preliminary.« less
Ruhayel, Yasir; Tepeler, Abdulkadir; Dabestani, Saeed; MacLennan, Steven; Petřík, Aleš; Sarica, Kemal; Seitz, Christian; Skolarikos, Andreas; Straub, Michael; Türk, Christian; Yuan, Yuhong; Knoll, Thomas
2017-08-01
Miniaturized instruments for percutaneous nephrolithotomy (PNL), utilizing tracts sized ≤22 Fr, have been developed in an effort to reduce the morbidity and increase the efficiency of stone removal compared with standard PNL (>22 Fr). We systematically reviewed all available evidence on the efficacy and safety of miniaturized PNL for removing renal calculi. The review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses statement. Since it was not possible to perform a meta-analysis, the data were summarized in a narrative synthesis. After screening 2945 abstracts, 18 studies were included (two randomized controlled trials [RCTs], six nonrandomized comparative studies, and 10 case series). Thirteen studies were full-text articles and five were only available as congress abstracts. The size of tracts used in miniaturized procedures ranged from 22 Fr to 4.8 Fr. The largest mean stone size treated using small instruments was 980mm 2 . Stone-free rates were comparable in miniaturized and standard PNL procedures. Procedures performed with small instruments tended to be associated with significantly lower blood loss, while the procedure duration tended to be significantly longer. Other complications were not notably different between PNL types. Study designs and populations were heterogeneous. Study limitations included selection and outcome reporting bias, as well as a lack of information on relevant confounding factors. The studies suggest that miniaturized PNL is at least as efficacious and safe as standard PNL for the removal of renal calculi. However, the quality of the evidence was poor, drawn mainly from small studies, the majority of which were single-arm case series, and only two of which were RCTs. Furthermore, the tract sizes used and types of stones treated were heterogeneous. Hence, the risks of bias and confounding were high, highlighting the need for more reliable data from RCTs. Removing kidney stones via percutaneous nephrolithotomy (PNL) using smaller sized instruments (mini-PNL) appears to be as effective and safe as using larger (traditional) instruments, but more clinical research is needed. Copyright © 2017 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Ozgor, Faruk; Yanaral, Fatih; Savun, Metin; Ozdemir, Harun; Sarilar, Omer; Binbay, Murat
2017-07-29
In this study, we aim to evaluate the accuracy of STONE (stone size, tract length, obstruction, number of involved calyces, and essence/stone density), Clinical Research Office of the Endourological Society (CROES), and Guy's nephrolithometry scoring systems (NSS) in obese patients. The charts of patients who underwent percutaneous nephrolithotomy (PNL) between June 2008 and June 2016 were retrospectively analyzed. Calculations of the STONE, CROES, and Guy's NSS were performed by a resident who was well informed regarding each NSS. Patients were classified under nine scores according to STONE, four grades according to CROES, and four grades according to Guy's NSS. In total, 248 obese patients were enrolled in the study. Stone size was significantly higher in patients without stone-free status (p = 0.001). In patients who were stone-free and those with residual stones, the mean STONE score was 9.71 and 9.23 (p = 0.160), CROES was 172 and 129 (p = 0.001), and Guy's NSS was 1.67 and 2.75 (p = 0.001). Multivariate regression analysis identified the CROES and Guy's NSS were independent factors for PNL success in obese patients (p = 0.01 and p = 0.01, respectively). The CROES and Guy's NSS showed good accuracy with PNL success (AUC = 0.777 and AUC = 0.844, respectively). None of the three NSS systems were statically associated with a complication rate (p = 0.23 for STONE, p = 0.14 for CROES, and p = 0.51 for Guy's NSS). Our study demonstrated that CROES and Guy's NSS were independent predictors of stone-free rate following PNL in obese patients. Our study also revealed that three of the NSSs were not useful for predicting PNL complications in obese patients.
Shen, Pengfei; Wei, Wuran; Yang, Xiaochun; Zeng, Hao; Li, Xiong; Yang, Jie; Wang, Jia; Huang, Jiaoti
2010-10-01
The objective of this study is to investigate the influences of percutaneous nephrolithotomy (PNL) and open surgery nephrolithotomy on the systemic stress response, SIRS and renal function. Forty patients with kidney calculi were enrolled in the study. Twenty cases were randomized to the PNL group and the other twenty cases to the open surgery group. Levels of C-reactive protein (CRP), interleukin-6(IL-6), β(2)-microglobulin (β(2)-MG), respiration rate, heart rate, body temperature and white blood cell counts were examined. CRP and IL-6 were measured in all patients pre-operatively and on post-operative days 1, 3 and 6, respectively. There was significant difference in their pre- and post-operation levels (P < 0.05), with the peak of CRP and IL-6 observed at post-operative days 3 and 1, respectively. There was significant difference in both CRP and IL-6 between the two groups (P < 0.05). At post-operative day 1, there were 5 cases of SIRS in PNL group and 12 cases in open surgery group; there was significant difference between the two groups (P < 0.05). Serum β(2)-MG levels were measured as the same time as CRP and no significant changes were observed within or between the groups (P > 0.05). Urine β(2)-MG levels were also measured. There was significant difference between pre- and the first day post-PNL (P < 0.05); there was no significant difference between pre- and the third and sixth day post-PNL (P > 0.05). There was significant difference between pre- and first and third day post-open surgery (P < 0.05); but there was no significant difference between pre- and the sixth day post-open surgery (P > 0.05). There was significant difference between two groups at the first, third and sixth days (P < 0.05). The systemic stress response is activated both in PNL group and open surgery group to some extent. The degree of stress response of PNL is lower than that of open surgery, proving the advantages of PNL with reference to serum immunology. There were cases in both the groups with SIRS, but the degree of SIRS in PNL group was lesser than the other group. Both the groups have no obvious effect on glomerular filtration function after operation and have effect on renal tubular reabsorption in the early stage after operation; but the recovery of the PNL group is faster than the open surgery group. It is thus shown that PNL is much safer and more feasible and has lesser effect on renal function.
Advanced Waveform Simulation for Seismic Monitoring
2008-09-01
velocity model. The method separates the main arrivals of the regional waveform into 5 windows: Pnl (vertical and radial components), Rayleigh (vertical and...ranges out to 10°, including extensive observations of crustal thinning and thickening and various Pnl complexities. Broadband modeling in 1D, 2D...existing models perform in predicting the various regional phases, Rayleigh waves, Love waves, and Pnl waves. Previous events from this Basin-and-Range
Deem, Samuel; Defade, Brian; Modak, Asmita; Emmett, Mary; Martinez, Fred; Davalos, Julio
2011-10-01
To compare the outcomes of percutaneous nephrolithotomy (PNL) and extracorporeal shock wave lithotripsy (ESWL) for moderate sized (1-2 cm) upper and middle pole renal calculi in regards to stone clearance rate, morbidity, and quality of life. All patients diagnosed with moderate sized upper and middle pole kidney stones by computed tomography (CT) were offered enrollment. They were randomized to receive either ESWL or PNL. The SF-8 quality of life survey was administered preoperatively and at 1 week and 3 months postoperatively. Abdominal radiograph at 1 week and CT scan at 3 months were used to determine stone-free status. All complications and outcomes were recorded. PNL established a stone-free status of 95% and 85% at 1 week and 3 months, respectively, whereas ESWL established a stone-free status of 17% and 33% at 1 week and 3 months, respectively. Retreatment in ESWL was required in 67% of cases, with 0% retreatment in PNL. Stone location, stone density, and skin-to-stone distance had no impact on stone-free rates at both visits, irrespective of procedure. Patient-reported outcomes, including overall physical and mental health status, favored a better quality of life for patients who had PNL performed. PNL more often establishes stone-free status, has a more similar complication profile, and has similar reported quality of life at 3 months when compared with ESWL for moderate-sized kidney stones. PNL should be offered as a treatment option to all patients with moderate-sized kidney stones in centers with experienced endourologists. Copyright © 2011 Elsevier Inc. All rights reserved.
Koo, Kyo Chul; Park, Sang Un; Jang, Ho Sung; Hong, Chang-Hee
2015-11-01
The purpose of this study was to determine the efficacy and safety of tubeless percutaneous nephrolithotomy (PNL) using a non-absorbable hemostatic sealant (Quikclot(®)) as an adjunct compared to nephrostomy tube placement in patients exhibiting significant parenchymal bleeding following PNL. We identified 113 PNL cases performed between May 2011 and October 2014. For patients with insignificant parenchymal bleeding following stone removal, defined as a clear visualization of the surgical field at full irrigation of the nephroscope, tubeless PNL was performed. For patients with significant parenchymal bleeding, we introduced the tubeless Quikclot(®) technique as of September 2013 and have performed it ever since. Formerly, nephrostomy placement PNL was performed. In this study, 40 Quikclot(®) applied PNL cases were matched with an equal number of nephrostomy placement cases by propensity scoring based on body mass index, stone size, and Guy's stone score. The mean postoperative drop in hematocrit was comparative between the Quikclot(®) group and the nephrostomy group on both postoperative days 1 (p = 0.459) and 2 (p = 0.325). Quikclot(®) application was associated with lower VAS scores throughout the postoperative period, lower cumulative analgesic requirement (p = 0.025), and with shorter hospitalization (p = 0.002). Complication rates were comparable with no need for blood transfusions in any patients. Tubeless Quikclot(®) PNL was safe and provided effective hemostasis of significant parenchymal bleeding. By avoiding nephrostomy placement, we were able to reduce postoperative pain, analgesic requirements, and hospitalization. Application of Quikclot(®) may be considered prior to nephrostomy placement in patients with significant parenchymal bleeding.
Gnessin, Ehud; Mandeville, Jessica A; Handa, Shelly E; Lingeman, James E
2012-04-01
Noncontrast computed tomography (CT) is commonly utilized after percutaneous nephrolithotomy (PNL) to assess stone-free (SF) status. In addition to assessing SF status, CT is useful in the recognition of complications after PNL. We characterized complications demonstrated by postoperative CT scan and compared hospital re-admission rates based on whether or not CT was performed. We retrospectively reviewed records of 1032 consecutive patients from April 1999 to June 2010. Patients were divided into two cohorts based on whether they had a CT within 24 hours of PNL. Demographic data, CT findings, and need for re-admission for complication management were assessed. Nine hundred fifty-seven patients (92.7%) underwent post-PNL CT. CT-diagnosed complications were perinephric hematoma in 41 (4.3%; 2 requiring embolization and 9 necessitating transfusion), pleural effusion in 25 (2.6%; 10 requiring intervention), colon perforation in 2 (0.2%), and splenic injury in 2 (0.2%). Of patients with postoperative complications, 33% required intervention. Among patients with a CT, 6 (0.6%) were readmitted despite negative postoperative CT (four perinephric hematomas, one calyceal-pleural fistula, and one pseudoaneurysm). The sensitivity of CT for diagnosing complications was 92.7%. Seventy-five patients (7.3%) did not undergo CT post-PNL. Of these, four (5.33%) were readmitted: three for perinephric hematomas and one for ureteral clot obstruction. Patients undergoing post-PNL CT were less likely to be readmitted because of missed complications (p=0.02). Serious post-PNL complications are uncommon, but their prompt diagnosis and treatment is imperative. In addition to identifying residual stones, CT is useful in diagnosing postoperative complications. Postoperative CT could potentially be considered for all patients undergoing PNL, particularly in complex cases such as patients with anatomical abnormalities (renal anatomic abnormality or retrorenal colon), patients requiring upper pole access (risk of thoracic, hepatic, and splenic complications), and patients requiring multisite access (higher risk of perinephric hematoma or need for transfusion).
Yamada, Kazuteru; Kaneko, Jun; Kamio, Yoshiyuki; Itoh, Yoshifumi
2008-01-01
Pectobacterium carotovorum subsp. carotovorum strain Er simultaneously produces the phage tail-like bacteriocin carotovoricin (Ctv) and pectin lyase (Pnl) in response to DNA-damaging agents. The regulatory protein RdgB of the Mor/C family of proteins activates transcription of pnl through binding to the promoter. However, the optimal temperature for the synthesis of Ctv (23°C) differs from that for synthesis of Pnl (30°C), raising the question of whether RdgB directly activates ctv transcription. Here we report that RdgB directly regulates Ctv synthesis. Gel mobility shift assays demonstrated RdgB binding to the P0, P1, and P2 promoters of the ctv operons, and DNase I footprinting determined RdgB-binding sequences (RdgB boxes) on these and on the pnl promoters. The RdgB box of the pnl promoter included a perfect 7-bp inverted repeat with high binding affinity to the regulator (Kd [dissociation constant] = 150 nM). In contrast, RdgB boxes of the ctv promoters contained an imperfect inverted repeat with two or three mismatches that consequently reduced binding affinity (Kd = 250 to 350 nM). Transcription of the rdgB and ctv genes was about doubled at 23°C compared with that at 30°C. In contrast, the amount of pnl transcription tripled at 30°C. Thus, the inverse synthesis of Ctv and Pnl as a function of temperature is apparently controlled at the transcriptional level, and reduced rdgB expression at 30°C obviously affected transcription from the ctv promoters with low-affinity RdgB boxes. Pathogenicity toward potato tubers was reduced in an rdgB knockout mutant, suggesting that the RdgAB system contributes to the pathogenicity of this bacterium, probably by activating pnl expression. PMID:18689515
Ergin, Giray; Kirac, Mustafa; Kopru, Burak; Ebiloglu, Turgay; Biri, Hasan
2018-04-22
To compare the pain status and stone free rates of flexible ureterorenoscopy (F-URS) versus mini-percutaneousnephrolithotomy (mini-PNL) for the treatment of 1-to 2-cm renal stones. This study was retrospectively designed with match paired method. Between January 2013 and December 2016, 387 patients underwent stone surgery for renal stones, 45 patients underwent FURS and 45 patients underwent mini-PNL. 90 patients were divided into two groups according to the surgical procedures. Group 1 patients underwent F-URS, and Group 2 patients underwent mini-PNL. During the intraoperative andpostoperative periods, pain management for all patients was standardized. Pain scores were determined using a visual analogue scale (VAS) completed at 2, 6, 12 and 24 hours postoperatively. The stone free status, hemoglobin levels, fluoroscopy time (FT), operation time (OT), hospitalization time (HT), return to work time (RWT), and complications were noted for each patient. Of all patients, the mean age was 41.1 ± 12.1 years and the mean stone size was 13.9 ± 2.9 mm. The VAS scores were significantly higher in the mini-PNL group at 2, 6, 12 and 24 hours (P < .05). The stone-free status and complication rates were similar between the two groups (P > .05); however, the hemoglobin decreases and the fluoroscopy, operation, hospitalization and return to work times were higher in the mini-PNL group than in the F-URS group (P < .05). F-URS is less painful than mini-PNL for the treatment of 1- to 2-cm renal stones. However, the stone free rate is similar between the two procedures while mini-PNL is superior in terms of fluoroscopy, operation, hospitalization and return to work duration. We think that F-URS is more comfortable and less painful than mini-PNL and achieves a similar stone free rate for the treatment of 1- to 2-cm renal stones.
Survey of Forensic Document Examination Habit Areas: Degree of Use and Discriminatory Power
DOE Office of Scientific and Technical Information (OSTI.GOV)
G Sperry; PA Manzolillo; RC Hanlan
Beginning in 1998, the Pacific Northwest National Laboratory (PNL), US Postal Inspection Service Forensic Laboratory (USPIS), and the Data Fusion Laboratory, Drexel University (DFL) have been collaborating on a large scale research project ''Handwriting Individuality--Moving From Art to Science''. In April 1998 a survey was distributed to the community of forensic document examiners (FDEs) requesting input on the habit areas used and their utility in distinguishing handwriting. The information obtained from this survey was intended to provide the data necessary to select the criteria and begin the evaluation of the handwriting samples currently in the project. Preliminary results of themore » survey were made available to the community at the American Society of Questioned Document Examiners (ASQDE) meeting in August 1998 and the American Academy of Forensic Sciences (AAFS) meeting in February 1999. This report provides final documentation of the survey and its results. This survey has two objectives: (1) to compile a list of handwriting features and characteristics used by professional forensic document examiners in the examination and comparison of handwriting and (2) to gather information about the significance of these features and characteristics. These objectives are met by having the FDEs provide an indication of their experience in the frequency of habit area evaluation and the utility of the habit area for discrimination.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heubach, J.G.; Hunt, S.T.; Pond, L.R.
1992-06-01
Information management technology has proliferated in the past decade in response to the information explosion. As documentation accumulates, the need to access information residing in manuals, handbooks and regulations conveniently, accurately, and quickly has increased. However, studies show that only fractions of the available information is read (Martin, 1978). Consequently, one of the biggest challenges in linking information and electronic management of information is to use the power of communication technology to meet the information needs of the audience. Pacific Northwest Laboratories' (PNL) investigation of translating its print manual system to an on-line system fits this challenge precisely. PNL's manualsmore » contain a tremendous amount of information for which manual holders are responsible. To perform their tasks in compliance with policy and procedure guidelines, users need to access information accurately, conveniently, and quickly. In order to select and use information management tools wisely, answers must be sought to a few basic questions. Communication experts cite four key questions: What do users want What do users need What characteristics of an on-line information system affect its usefulness Who are the users whose wants and needs are to be met Once these questions are answered, attention can be focused on finding the best match between user requirements and technology characteristics and weighing the costs and benefits of proposed options.« less
Hydromagnetic Waves and Instabilities in Kappa Distribution Plasma
2009-01-01
perpendicular effective particle temperatures, respec- tively. Two other parameters related to pM and pnl which naturally occur in the study of...role in determin- ing the excitation conditions of the field swelling and mirror instabilities [see Eqs. (60) and (65)]. Calculating pnl /pni from Eq...more convenient form of the perturbed distribution function /„ that may be used in- stead of Eq. (12) to obtain nn, pM, and pnl given by Eqs. (72
Adhoc Wireless Network Control: Energy Efficiency and Hidden Terminal Considerations
2009-12-01
Pnl (t) +Bn(t), Emax ) , (57) Ynl(t+ 1) = [Ynl(t)−Rnl,in(t)] + + γnl(t), (58) Dn(t+ 1) = [Dn(t...1− δ)Bn(t)] + + ∑ l∈On Pnl (t), (59) subject to constraints Rnl,in(t) ≤ Vnl(t) +Anl(t) ∀n, l, t, P (t) ∈ PS(t), ∑ l∈On Pnl (t) ≤ min ( En(t), P̂ ) ∀n...γnl(t)] ∣ ∣ ∣ ∣ ∣ ∣ X(t) − 2E ∑ n,l [Unl(t)µnl (S(t),P (t))−Dn(t) Pnl (t)] ∣ ∣ ∣ ∣ ∣ ∣ X(t) − 2E ∑ n,l [ηYnl(t)−
Does body mass index effect the success of percutaneous nephrolithotomy?
Şimşek, Abdülmuttalip; Özgör, Faruk; Akbulut, Mehmet Fatih; Küçüktopçu, Onur; Berberoğlu, Ahmet Yalçın; Sarılar, Ömer; Binbay, Murat; Müslümanoğlu, Ahmet Yaser
2014-01-01
Objective: In obese patients, the management of renal calculi presents a number of challenges for urologists. In this study, we aimed to evaluate the efficacy and safety of percutaneous nephrolithotomy (PNL) procedure in obese and morbidly obese patients. Material and methods: We retrospectively reviewed the medical files of 2360 patients treated with PNL between March 2002 and April 2013. The patients were stratified into four groups according to the World Health Organization (WHO) classification of body mass index (BMI): <25 kg/m2 (average), 25–29.9 kg/m2 (overweight), 30–39.9 kg/m2 (obese), and >40 kg/m2 (morbidly obese). Patients under 18 years of age and those with a body mass index under 18 kg/m2 were excluded from the study. Intra-, and postoperative outcomes of PNL were compared between groups. Results: A total of 2102 patients with a mean age of 43±13.62 years were enrolled in the study. The mean stone size, mean number of stones, staghorn stone rate and history of previous shock wave lithotripsy were similar in all groups. The overall stone-free rate was 82 percent. The mean operation time was longer in the morbidly obese group but it was not significantly different from that in the other groups. No differences were observed in hospital stay, complication or stone-free rate among four study groups. Conclusion: Percutaneous nephrolithotomy is a safe and effective treatment for renal stone disease. Body mass index does not affect the success or complication rate in PNL. PMID:26328160
The effects of previous open renal stone surgery types on PNL outcomes
Ozgor, Faruk; Kucuktopcu, Onur; Ucpinar, Burak; Sarilar, Omer; Erbin, Akif; Yanaral, Fatih; Sahan, Murat; Binbay, Murat
2016-01-01
Introduction: Our aim was to demonstrate the effect of insicion of renal parenchyma during open renal stone surgery (ORSS) on percutaneous nephrolithotomy (PNL) outcomes. Methods: Patients with history of ORSS who underwent PNL operation between June 2005 and June 2015 were analyzed retrospectively. Patients were divided into two groups according to their type of previous ORSS. Patients who had a history of ORSS with parenchymal insicion, such as radial nephrotomies, anatrophic nephrolithotomy, lower pole resection, and partial nephrectomy, were included in Group 1. Other patients with a history of open pyelolithotomy were enrolled in Group 2. Preoperative characteristics, perioperative data, stone-free status, and complications were compared between the groups. Stone-free status was defined as complete clearance of stone(s) or presence of residual fragments smaller than 4 mm. The retrospective nature of our study, different experience level of surgeons, and lack of the evaluation of anesthetic agents and cost of procedures were limitations of our study. Results: 123 and 111 patients were enrolled in Groups 1 and 2, respectively. Preoperative characteristics were similar between groups. In Group 1, the mean operative time was statistically longer than in Group 2 (p=0.013). Stone-free status was significantly higher in Group 2 than in Group 1 (p=0.027). Complication rates were similar between groups. Hemorrhage requiring blood transfusion was the most common complication in both groups (10.5% vs. 9.9%). Conclusions: Our study demonstrated that a history of previous ORSS with parenchymal insicion significantly reduces the success rates of PNL procedure. PMID:28255416
Yuruk, Emrah; Gureser, Gokhan; Tuken, Murat; Ertas, Kasim
2016-01-01
Introduction The aim of this study was to demonstrate the efficacy of Instadose™, a novel dosimeter designed for radiation workers to provide a measurement of the radiation dose at any time from any computer; to determine the amount of radiation exposure during percutaneous nephrolithotomy (PNL); and to evaluate the factors that affect the amount of radiation exposed. Material and methods Two experienced surgeons wore Instadose™ on the outer part of their lead aprons during the PNL procedures performed between December 2013 and July 2014. Patient demographics and stone characteristics were noted. Factors affecting radiation dose were determined. Fluoroscopic screening time was compared with the amount of radiation in order to validate the measurements of Instadose™. Results Overall, 51 patients with a mean age of 43.41 ±18.58 (range 1–75) years were enrolled. Male to female ratio was 35/16. The amount of radiation was greater than 0.01mSv in only 19 (37.25%) cases. Stone location complexity (p = 0.380), dilation type (p = 0.584), stone size (p = 0.565), dilation size (p = 0.891) and access number (p = 0.268) were not associated with increased radiation exposure. Instadose™ measurements were correlated with fluoroscopic screening time (r = 0.519, p = 0.001). Conclusions Instadose™ is a useful tool for the measurement of radiation exposure during PNL. The advantage of measuring the amount of radiation exposure after each PNL operation is that it may aid urologists in taking appropriate precautions to minimize the risk of radiation related complications. PMID:27551558
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, R.R.; Klavetter, E.A.; Hall, I.J.
1984-12-01
The geological formations in the unsaturated zone at Yucca Mountain, on and adjacent to the Nevada Test Site (NTS), are currently being studied for consideration as the host for a radioactive-waste repository; the US Department of Energy is carrying out these studies through the Nevada Nuclear Waste Storage Investigations project. The formations are composed of tuffaceous (tuff) materials that must be evaluated to estimate the rate at which radionuclides would migrate to the accessible environment. According to the available evidence, the flux of water in the unsaturated zone beneath the Yucca Mountain site is low; quantifying such low flow ratesmore » through direct measurements is difficult. To help provide data that can be used to assess unsaturated flow, Pacific Northwest Laboratory (PNL), under contract to Sandia National Laboratories (SNL), performed hydrologic tests on tuffaceous samples from 48 different locations in Yucca Mountain. This report contains the entire set of psychrometer measurements of desaturation curves for tuffs from Yucca Mountain as well as a substantial number of saturated conductivity measurements. 19 references, 132 figures, 23 tables.« less
Analysis of the impact of safeguards criteria
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mullen, M.F.; Reardon, P.T.
As part of the US Program of Technical Assistance to IAEA Safeguards, the Pacific Northwest Laboratory (PNL) was asked to assist in developing and demonstrating a model for assessing the impact of setting criteria for the application of IAEA safeguards. This report presents the results of PNL's work on the task. The report is in three parts. The first explains the technical approach and methodology. The second contains an example application of the methodology. The third presents the conclusions of the study. PNL used the model and computer programs developed as part of Task C.5 (Estimation of Inspection Efforts) ofmore » the Program of Technical Assistance. The example application of the methodology involves low-enriched uranium conversion and fuel fabrication facilities. The effects of variations in seven parameters are considered: false alarm probability, goal probability of detection, detection goal quantity, the plant operator's measurement capability, the inspector's variables measurement capability, the inspector's attributes measurement capability, and annual plant throughput. Among the key results and conclusions of the analysis are the following: the variables with the greatest impact on the probability of detection are the inspector's measurement capability, the goal quantity, and the throughput; the variables with the greatest impact on inspection costs are the throughput, the goal quantity, and the goal probability of detection; there are important interactions between variables. That is, the effects of a given variable often depends on the level or value of some other variable. With the methodology used in this study, these interactions can be quantitatively analyzed; reasonably good approximate prediction equations can be developed using the methodology described here.« less
Trainee-Associated Factors and Proficiency at Percutaneous Nephrolithotomy.
Aghamir, Seyed Mohammad Kazem; Behtash, Negar; Hamidi, Morteza; Farahmand, Hasan; Salavati, Alborz; Mortaz Hejri, Sara
2017-07-01
Percutaneous nephrolithotomy (PNL) is a complicated procedure for urology trainees. This study was designed to investigate the effect of trainees' ages and previous experience, as well as the number of operated cases, on proficiency at PNL by using patient outcomes. A cross sectional observational study was designed during a five-year period. Trainees in PNL fellowship programs were included. At the end of the program, the trainees' performance in PNL was assessed regarding five competencies and scored 1-5. If the overall score was 4 or above, the trainee was considered as proficient. The trainees' age at the beginning of the program and the years passed from their residency graduation were asked and recorded. Also, the number of PNL cases operated by each trainee was obtained via their logbooks. The age, years passed from graduation, and number of operated cases were compared between two groups of proficient and non-proficient trainees. Univariate and multivariate binary logistic regression analysis was applied to estimate the effect of aforementioned variables on the occurrence of the proficiency. Forty-two trainees were included in the study. The mean and standard deviation for the overall score were 3.40 (out of 5) and 0.67, respectively. Eleven trainees (26.2%) recognized as proficient in performing PNL. Univariate regression analysis indicated that each of three variables (age, years passed from graduation and number of operated cases) had statistically significant effect on proficiency. However, the multivariate regression analysis revealed that just the number of cases had significant effect on achieving proficiency. Although it might be assumed that trainees' age negatively correlates with their scores, in fact, it is their amount of practice that makes a difference. A certain number of cases is required to be operated by a trainee in order to reach the desired competency in PNL.
Does the nephrostomy tract length impact the outcomes of percutaneous nephrolithotomy (PNL)?
Astroza, Gaston M; Neisius, Andreas; Tsivian, Matvey; Wang, Agnes J; Preminger, Glenn M; Lipkin, Michael E
2014-12-01
Different factors can determine the outcomes of percutaneous nephrolithotomy (PNL). We analyzed the effect of tract length (TL) on outcomes after PNL. We performed a retrospective review of patients undergoing PNL between 2006 and 2011. Patients with preoperative computed tomography (CT), one percutaneous access tract and follow-up imaging within 3 months were included. TL was defined as distance between the skin to the calyx of puncture as measured on preoperative CT. Measurements were independently performed by two urologists and the average was used for analysis. Stone-free rate (SFR) was defined as zero fragments on follow-up imaging. Factors independently associated with the likelihood of being stone-free after PNL were determined using multivariable analysis adjusted for TL, location of access, the presence of incomplete or complete staghorn calculi and type of follow-up imaging. Complications (Clavien score) were independently assessed. A total of 222 patients were included. Median stone burden and body mass index (BMI) was 239.4 mm(2) and 30.5 [interquartile range (IQR): 25.7-36.2]. The median TL was 85.0 mm (IQR: 70.3-100.0) and highly correlated with BMI (ρ = 0.66, p < 0.001). A total of 101 patients (45.5 %) were stone-free. TL was not associated with SFR (p = 0.53). Clavien 1 and 2 complications occurred in 38 (17 %) while Clavien 3 and 4 complications occurred in 17 (8 %) patients. Multivariable analysis revealed no association between complications and TL even when adjusted for gender. Percutaneous TL is not associated with outcomes of PNL. PNL is a safe and effective treatment for stones in patients with differing body habitus.
[Ultraminipercutaneous nephrolithotripsy in treating kidney stones].
Martov, A G; Dutov, S V; Andronov, A S
2016-04-01
Percutaneous nephrolithotripsy (PNL) is the recommended method of surgical treatment of kidney stones of size greater than 2 cm. Trends in the development of modern urology have been steadily toward less traumatic method to treat nephrolithiasis - minimally invasive PNL. The present work aimed to explore of the possibilities of one of the modern variants of minimally invasive PNL - ultra-mini-PNL in treating nephrolithiasis. The study included 60 patients (mean age 45.6+/-7.2 years) with isolated kidney calculus, up to 2.0 cm or several stones with a total size of up to 2.5 cm. All patients were found to have 77 kidney stones, six of which had a size of 10 mm, 51 had a size of 11-15 mm and 20 had a size of 16-20 mm. 45% of patients had isolated renal pelvic stones and 28.3% had stones in the renal pelvis and lower calyx. All patients underwent ultra-mini-PNL using nephroscope size 7.5 Ch and tube size 12 Fr. The average duration of surgery from the moment of the puncture of the pyelocaliceal system to installing the nephrostomy tube was 65.4 minutes. Complete clearance of stones after single-stage ultra-mini-PNL was observed in 80% of cases. Nephrostomy tube was removed on days 2-3. The average postoperative hospital stay was 5.1 days. The most common complication was postoperative exacerbation of pyelonephritis (13.3% of patients), successfully treated with conservative measures. There were no cases of postoperative bleeding, accompanied by anemia and needed a blood transfusion. Considering high effectiveness and low rate of complications of ultra-mini-PNL, it can be successfully used in treating nephrolithiasis among a wide group of patients.
2008-09-30
propagation effects by splitting apart the longer period surface waves from the shorter period, depth-sensitive Pnl waves. Problematic, or high-error... Pnl waves. Problematic, or high-error, stations and paths were further analyzed to identify systematic errors with unknown sensor responses and...frequency Pnl components and slower, longer period surface waves. All cut windows are fit simultaneously, allowing equal weighting of phases that may be
Investigation of self-help oil-spill response techniques and equipment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Enderlin, W I; Downing, J P; Enderlin, C W
1992-06-01
The US Coast Guard commissioned Pacific Northwest Laboratory (PNL) to conduct this study of 45 self-help oil-spill response techniques and equipment for oceangoing tankers and inland tank barges to assess the potential effectiveness of the proposed countermeasure categories. This study considers the hypothetical outflow of oil in the case of side damage and bottom damage to single-hull designs. The results will be considered by the Coast Guard in drafting regulations pertaining to the requirement for tanker vessels to carry oil pollution response equipment (i.e., in response to the oil Pollution Act of 1990). PNL's approach to this investigation included: assessingmore » time-dependent oil outflow in the cases of collision and grounding of both tankers and barges; identifying environmental constraints on self-help countermeasure operation; identifying human factor issues, such as crew performance, safety, and training requirements for the self-help countermeasures considered; and assessing each self-help countermeasure with respect to its potential for minimizing oil loss to the environment. Results from the time-dependent oil outflow, environmental limitations, and human factors requirements were input into a simulation model.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lumetta, C.C.; Park, J.F.
1994-03-01
This report summarizes FY 1993 progress in biological and general life sciences research programs conducted for the Department of Energy`s Office of Health and Environmental REsearch (OHER) at Pacific Northwest Laboratory (PNL). This research provides knowledge of fundamental principles necessary to identify, understand, and anticipate the long-term health consequences of exposure to energy-related radiation and chemicals. The Biological Research section contains reports of studies using laboratory animals, in vitro cell systems, and molecular biological systems. This research includes studies of the impact of radiation, radionuclides, and chemicals on biological responses at all levels of biological organization. The General Life Sciencesmore » Research section reports research conducted for the OHER human genome program.« less
Pacific Northwest Laboratory annual report for 1991 to the DOE Office of Energy Research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, J.F.
1992-09-01
This report summarizes progress in OHER biological research and general life sciences research programs conducted conducted at PNL in FLY 1991. The research develops the knowledge and scientific principles necessary to identify, understand, and anticipate the long- term health consequences of energy-related radiation and chemicals. Our continuing emphasis is to decrease the uncertainty of health risk estimates from existing and newly developed energy-related technologies through an increased understanding of the ways in which radiation and chemicals cause biological damage.
Hanford Internal Dosimetry Program Manual, PNL-MA-552
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carbaugh, Eugene H.; Bihl, Donald E.; Maclellan, Jay A.
2009-09-24
This manual is a guide to the services provided by the Hanford Internal Dosimetry Program (IDP), which is operated by the Pacific Northwest National Laboratory.( ) for the U.S. Department of Energy Richland Operations Office, Office of River Protection and their Hanford Site contractors. The manual describes the roles of and relationships between the IDP and the radiation protection programs of the Hanford Site contractors. Recommendations and guidance are also provided for consideration in implementing bioassay monitoring and internal dosimetry elements of radiation protection programs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liebetrau, A.M.
Work is underway at Pacific Northwest Laboratory (PNL) to improve the probabilistic analysis used to model pressurized thermal shock (PTS) incidents in reactor pressure vessels, and, further, to incorporate these improvements into the existing Vessel Integrity Simulation Analysis (VISA) code. Two topics related to work on input distributions in VISA are discussed in this paper. The first involves the treatment of flaw size distributions and the second concerns errors in the parameters in the (Guthrie) equation which is used to compute ..delta..RT/sub NDT/, the shift in reference temperature for nil ductility transition.
2009-07-07
inversion technique that is based on different weights for relatively high frequency waveform modeling of Pnl and relatively long period surface waves (Tan...et al., 2006). Pnl and surface waves are also allowed to shift in time to take into account of uncertainties in velocity structure. Joint...inversion of Pnl and surface waves provides better constraints on focal depth as well as source mechanisms. The pure strike-slip mechanism of the earthquake
Radiation exposure of patient and surgeon in minimally invasive kidney stone surgery.
Demirci, A; Raif Karabacak, O; Yalçınkaya, F; Yiğitbaşı, O; Aktaş, C
2016-05-01
Percutaneous nephrolithotomy (PNL) and retrograde intrarenal surgery (RIRS) are the standard treatments used in the endoscopic treatment of kidney stones depending on the location and the size of the stone. The purpose of the study was to show the radiation exposure difference between the minimally invasive techniques by synchronously measuring the amount of radiation the patients and the surgeon received in each session, which makes our study unique. This is a prospective study which included 20 patients who underwent PNL, and 45 patients who underwent RIRS in our clinic between June 2014 and October 2014. The surgeries were assessed by dividing them into three steps: step 1: the access sheath or ureter catheter placement, step 2: lithotripsy and collection of fragments, and step 3: DJ catheter or re-entry tube insertion. For the PNL and RIRS groups, mean stone sizes were 30mm (range 16-60), and 12mm (range 7-35); mean fluoroscopy times were 337s (range 200-679), and 37s (range 7-351); and total radiation exposures were 142mBq (44.7 to 221), and 4.4mBq (0.2 to 30) respectively. Fluoroscopy times and radiation exposures at each step were found to be higher in the PNL group compared to the RIRS group. When assessed in itself, the fluoroscopy time and radiation exposure were stable in RIRS, and the radiation exposure was the highest in step 1 and the lowest in step 3 in PNL. When assessed for the 19 PNL patients and the 12 RIRS patients who had stone sizes≥2cm, the fluoroscopy time in step 1, and the radiation exposure in steps 1 and 2 were found to be higher in the PNL group than the RIRS group (P<0.001). Although there is need for more prospective randomized studies, RIRS appears to be a viable alternate for PNL because it has short fluoroscopy time and the radiation exposure is low in every step. 4. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fleischman, R.M.; Goldsmith, S.; Newman, D.F.
1981-09-01
The objective of the Advanced Reactor Design Study (ARDS) is to identify and evaluate nonbackfittable concepts for improving uranium utilization in light water reactors (LWRs). The results of this study provide a basis for selecting and demonstrating specific nonbackfittable concepts that have good potential for implementation. Lead responsibility for managing the study was assigned to the Pacific Northwest Laboratory (PNL). Nonbackfittable concepts for improving uranium utilization in LWRs on the once-through fuel cycle were selected separately for PWRs and BWRs due to basic differences in the way specific concepts apply to those plants. Nonbackfittable concepts are those that are toomore » costly to incorporate in existing plants, and thus, could only be economically incorporated in new reactor designs or plants in very early stages of construction. Essential results of the Advanced Reactor Design Study are summarized.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, M.K.
1994-06-01
The United States Department of Energy (DOE) faces the major task of cleaning up hundreds of waste sites across the nation, which will require completion of a large number of remedial investigation/feasibility studies (RI/FSs). The intent of each RI/FS is to characterize the waste problems and environmental conditions at the operable unit level, segment the remediation problem into manageable medium-specific and contaminant-specific pieces, define corresponding remediation objectives, and identify remedial response actions to satisfy those objectives. The RI/FS team can then identify combinations of remediation technologies that will meet the remediation objectives. Finally, the team must evaluate these remedial alternativesmore » in terms of effectiveness, implementability, cost, and acceptability. The Remedial Action Assessment System (RAAS) is being developed by Pacific Northwest Laboratory (PNL) to support DOE in this effort.« less
User's manual for the BNW-II optimization code for dry/wet-cooled power plants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Braun, D.J.; Bamberger, J.A.; Braun, D.J.
1978-05-01
The User's Manual describes how to operate BNW-II, a computer code developed by the Pacific Northwest Laboratory (PNL) as a part of its activities under the Department of Energy (DOE) Dry Cooling Enhancement Program. The computer program offers a comprehensive method of evaluating the cost savings potential of dry/wet-cooled heat rejection systems. Going beyond simple ''figure-of-merit'' cooling tower optimization, this method includes such items as the cost of annual replacement capacity, and the optimum split between plant scale-up and replacement capacity, as well as the purchase and operating costs of all major heat rejection components. Hence the BNW-II code ismore » a useful tool for determining potential cost savings of new dry/wet surfaces, new piping, or other components as part of an optimized system for a dry/wet-cooled plant.« less
[Solitary stones of the lower renal calyx: how to treat?
Martov, A G; Ergakov, D V; Andronov, A S; Dutov, S V; Takhaev, R A; Kil'chukov, Z I; Moskalenko, S A
2017-06-01
The choice of treatment for the stones of the lower renal calyx is one of the challenging issues of modern urology. The aim of this retrospective and prospective study was to investigate the clinical effectiveness and safety of 3 modern minimally invasive techniques for treating renal stones: percutaneous (PNL) and transurethral (TNL) nephrolithotripsy and extracorporeal shock wave lithotripsy (ESWL) in patients with solitary lower calyx stones sized from 10 to 15 mm. The study included 136 patients with symptomatic stones of the lower calyces, who underwent ESWL, PNL and TNL from November 2010 to the present day. The criteria for inclusion in the study were: the presence of a solitary stone of the lower calyx, the stone size of 10 mm to 15 mm, the performance of the classical (standard) PNL in the prone position (puncture access 28-30 Fr) and the follow-up examination at 3 months after the operation. Forty-six patients underwent ESWL, 49 - PNL, and 41 - TNL. Postoperative follow-up was done at 3 months and included a plain radiography, ultrasound and non-contrast-enhanced computed tomography. The stone free rate (SFR) was used as a criterion for the effectiveness of the intervention, where the stone size of 3 mm was taken as the upper limit for the possible presence of fragments. Besides, the rate of repeat interventions, complications and subjective assessment of patients treatment satisfaction (0 to 10) by using visual analogue scale (VAS) were investigated. The effectiveness analysis of the three methods for treating the lower calyx stones sized 10-15 mm showed that PNL was no more effective than TNL (SFR 95.9% and 85.4%, respectively), but both methods were significantly more effective than ESWL (SFR 69.5%). 29.3% of patients who underwent TNL required repeat interventions (TNL or ESWL), while among those treated with ESWL, 45.6% required repeat ESWL sessions. PNL resulted in stone clearance in one stage. Postoperative inflammatory complications were most prevalent among patients who underwent TNL (26.8%). Bleeding requiring hemotransfusion was observed only after PNL (14.3%). Obstructive complications were observed in all study groups. For them, internal stenting was most often performed after ESWL (10.9%), puncture nephrostomy - after TNL (7.3%). Statistically significantly higher VAS measured quality of life was found after ESWL (7.9) and PNL (7.0) compared with THL (4.8). All three methods (PNL, TNL and ESWL) for treating lower calyceal stones sized from 10 to 15 mm are quite effective. Using them separately or in combination allows most patients to safely achieve a stone-free state.
Cetinkaya, Mehmet; Buldu, Ibrahim; Kurt, Omer; Inan, Ramazan
2017-08-29
The first purpose of this study was to reveal factors affecting the postoperative development of systemic inflammatory response syndrome (SIRS) in patients undergoing standard percutaneous nephrolithotomy (PNL) for renal stones. The second purpose was to determine the role of the preoperative platelet-to-lymphocyte ratio (PLR) and the neutrophil-to-lymphocyte ratio (NLR) in the prediction of SIRS.Matarials and Methods: In total, 192 patients who had undergone conventional PNL for renal stones from 2013 to 2015 were included in the study. SIRS developed postoperatively in 41 (21.3%) patients. The patients were divided into SIRS and non-SIRS groups, and the effects of the PLR, NLR, and other demographic and operative data were investigated to predict the development of SIRS. Variables significant in the univariate analysis were evaluated using a multiple logistic regression model to determine the independent risk factors for developing SIRS after PNL. Univariate analysis revealed significant differences in the preoperative PLR (P < .001), preoperative NLR (P = .018), number of access sites (P < .001), mean renal parenchymal thickness (P = .02), operative time (P < .001), decrease in hemoglobin (P = .016), length of hospital stay (P < .001), stone-free status (P = .023), and complication rate between the two groups of patients. However, multivariate analysis showed that only the PLR and the number of access sites were independent factors affecting the development of SIRS. When the PLR cut-off value was 114.1, development of SIRS was predicted with 80.4% sensitivity and 60.2% specificity. The preoperative PLR is an effective and inexpensive biomarker with which to predict SIRS after PNL. In particular, we recommend close monitoring of patients with a PLR of >114.1 because of the possibledevelopment of serious complications.
Guo, Y S; Wang, J Q; Xu, C; Liu, Y N; He, X H; Wei, Q
2017-06-10
Objective: To Investigate the immune status and influencing factors of provincial polio network laboratory (PNL) workers in China so as to provide evidence for the development of related strategies to protect personnel working at the PNLs. Methods: All the practitioners from the PNLs at the provincial centers for disease control, were selected as objects for this study, from October to December, 2016, under a questionnaire survey. Information on status of immunity and influencing factors was collected, with SAS software, trend chi-square used for statistics analysis. Results: A total of 77 workers were involved in this survey, with 60 (78 % ) of them completed the polio-based immune program but the rest 17 (22 % ) remained records unclear. 66 people (about 86 % ) remembered clearly that they had received vaccination when engaging in the polio-lab work, but the rest 11 (14 % ) with only partial vaccination records. We also noticed that the Influencing factors realted to vaccination status were: age ( χ (2)=2.48, P <0.05), title ( χ (2)=2.51, P <0.05), years of employment ( P <0.000 1), education ( χ (2)=0.74, P =0.46) and gender ( χ (2)=0.46, P =0.50). Conclusion: Immune status of the Chinese provincial PNL practitioners appeared fairly good as 86 % of all the workers had received polio-related vaccination, with 41 % of them completed a 3-time inoculation program, when started working in this field.
A laboratory study of subjective annoyance response to sonic booms and aircraft flyovers
NASA Technical Reports Server (NTRS)
Leatherwood, Jack D.; Sullivan, Brenda M.
1994-01-01
Three experiments were conducted to determine subjective equivalence of aircraft subsonic flyover noise and sonic booms. Two of the experiments were conducted in a loudspeaker-driven sonic boom simulator, and the third in a large room containing conventional loudspeakers. The sound generation system of the boom simulator had a frequency response extending to very low frequencies (about 1 Hz) whereas the large room loudspeakers were limited to about 20 Hz. Subjective equivalence between booms and flyovers was quantified in terms of the difference between the noise level of a boom and that of a flyover when the two were judged equally annoying. Noise levels were quantified in terms of the following noise descriptors: Perceived Level (PL), Perceived Noise Level (PNL), C-weighted sound exposure level (SELC), and A-weighted sound exposure level (SELA). Results from the present study were compared, where possible, to similar results obtained in other studies. Results showed that noise level differences depended upon the descriptor used, specific boom and aircraft noise events being compared and, except for the PNL descriptor, varied between the simulator and large room. Comparison of noise level differences obtained in the present study with those of other studies indicated good agreement across studies only for the PNL and SELA descriptors. Comparison of the present results with assessments of community response to high-energy impulsive sounds made by Working Group 84 of the National Research Council's Committee on Hearing, Bioacoustics, and Biomechanics (CHABA) showed good agreement when boom/flyover noise level differences were based on SELA. However, noise level differences obtained by CHABA using SELA for aircraft flyovers and SELC for booms were not in agreement with results obtained in the present study.
Safety of percutaneous nephrolithotomy in patients on chronic anticoagulant or antiplatelet therapy.
Fernández-Baltar, C; Pérez-Fentes, D; Sánchez-García, J F; García-Freire, C
2018-01-22
In developed countries, the incidence of cardiovascular disease is increasing, therefore, anticoagulant and antiplatelet drugs are a widespread treatment nowadays. Percutaneous nephrolithotomy (PNL) is the first-line treatment for large or complex stones (> 2 cm) and remains an alternative for the smaller ones. The objective of this study is to analyze whether PNL surgery is a safe procedure in patients under a treatment discontinuation protocol for anticoagulant or antiplatelet therapies. We retrospectively studied 301 patients who underwent PNL in our hospital between 2008 and 2016 and identified 46 patients on chronic antiplatelet or anticoagulation treatment. With respect to PNL outcomes, the stone-free rate was similar (78 vs 74%, p = 0.762) in both groups, without any significant differences in the overall postoperative complications (17 vs 26%, p = 0.203). The incidence of hemorrhagic complications was similar between groups (12 vs 9%, p = 0.492), as demonstrated by the mean drop in hemoglobin (Hb), which was comparable in both cohorts (2.2 ± 1.3 vs 2.0 ± 1.4 p = 0.270) and the blood transfusion rate (14% in group A and 8% in group B, p = 0.205). No thromboembolic events were found within the year after the PNL procedure. PNL is a safe and effective intervention in patients under a treatment discontinuation protocol for anticoagulant or antiplatelet therapies. Although our study demonstrates the feasibility of this protocol, new scientific evidence aims to stratify the thromboembolic and bleeding risk of each patient to individualize the perioperative management thereafter.
Koyuncu, Hakan; Yencilek, Faruk; Kalkan, Mehmet; Bastug, Yavuz; Yencilek, Esin; Ozdemir, Ahmet Tunc
2015-01-01
To compare the efficacy of RIRS and PNL in lower pole stones ≥ 2 cm. Materials and and Methods: A total of 109 patients who underwent PNL or RIRS for solitary lower pole stone between April 2009 and December 2012, were retrospectively analyzed. Lower pole stone was diagnosed with CT scan. Stone size was assessed as the longest axis of the stone. All patients were informed about the advantages, disadvantages and probable complications of both PNL and RIRS before the selection of the procedure. Patients decided the surgery type by themselves without being under any influences and written informed consent was obtained from all patients prior to the surgery. Patients were divided into two groups according to the patients' preference of surgery type. Group 1 consisted of 77 patients who underwent PNL and Group 2 consisted of 32 patients treated with RIRS. Stone free statuses, postoperative complications, operative time and hospitalization time were compared in both groups. There was no statistical significance between the two groups in mean age, stone size, stone laterality, mean follow-up periods and mean operative times. In PNL group, stone-free rate was 96.1% at first session and 100% after the additional procedure. In Group 2, stone-free rate was 90.6% at the first procedure and 100% after the additional procedure. The final stone-free rates and operative times were similar in both groups. RIRS should be an effective treatment alternative to PNL in lower pole stones larger than 2 cm, especially in selected patients.
Koyuncu, Hakan; Yencilek, Faruk; Kalkan, Mehmet; Bastug, Yavuz; Yencilek, Esin; Ozdemir, Ahmet Tunc
2015-01-01
Purpose To compare the efficacy of RIRS and PNL in lower pole stones ≥2 cm. Materials and and Methods: A total of 109 patients who underwent PNL or RIRS for solitary lower pole stone between April 2009 and December 2012, were retrospectively analyzed. Lower pole stone was diagnosed with CT scan. Stone size was assessed as the longest axis of the stone. All patients were informed about the advantages, disadvantages and probable complications of both PNL and RIRS before the selection of the procedure. Patients decided the surgery type by themselves without being under any influences and written informed consent was obtained from all patients prior to the surgery. Patients were divided into two groups according to the patients’ preference of surgery type. Group 1 consisted of 77 patients who underwent PNL and Group 2 consisted of 32 patients treated with RIRS. Stone free statuses, postoperative complications, operative time and hospitalization time were compared in both groups. Results There was no statistical significance between the two groups in mean age, stone size, stone laterality, mean follow-up periods and mean operative times. In PNL group, stone-free rate was 96.1% at first session and 100% after the additional procedure. In Group 2, stone-free rate was 90.6% at the first procedure and 100% after the additional procedure. The final stone-free rates and operative times were similar in both groups. Conclusions RIRS should be an effective treatment alternative to PNL in lower pole stones larger than 2 cm, especially in selected patients. PMID:26005965
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anheier, N.C. Jr.; McDonald, C.E.; Cuta, J.M.
1995-05-01
This report describes an evaluation of various sensing techniques for determining the ammonia concentration in the working fluid of ammonia/water absorption cycle systems. The purpose of this work was to determine if any existing sensor technology or instrumentation could provide an accurate, reliable, and cost-effective continuous measure of ammonia concentration in water. The resulting information will be used for design optimization and cycle control in an ammonia-absorption heat pump. PNL researchers evaluated each sensing technology against a set of general requirements characterizing the potential operating conditions within the absorption cycle. The criteria included the physical constraints for in situ operation,more » sensor characteristics, and sensor application. PNL performed an extensive literature search, which uncovered several promising sensing technologies that might be applicable to this problem. Sixty-two references were investigated, and 33 commercial vendors were identified as having ammonia sensors. The technologies for ammonia sensing are acoustic wave, refractive index, electrode, thermal, ion-selective field-effect transistor (ISFET), electrical conductivity, pH/colormetric, and optical absorption. Based on information acquired in the literature search, PNL recommends that follow-on activities focus on ISFET devices and a fiber optic evanescent sensor with a colormetric indicator. The ISFET and fiber optic evanescent sensor are inherently microminiature and capable of in situ measurements. Further, both techniques have been demonstrated selective to the ammonium ion (NH{sub 4}{sup +}). The primary issue remaining is how to make the sensors sufficiently corrosion-resistant to be useful in practice.« less
Histologic and immunohistochemical predictors of clinical behavior for feline diffuse iris melanoma.
Wiggans, K Tomo; Reilly, Christopher M; Kass, Philip H; Maggs, David J
2016-07-01
To determine histologic and immunohistochemical predictors of metastasis of feline diffuse iris melanoma (FDIM). Globes from 47 client-owned cats enucleated for FDIM between January 1985 and December 2013. Hematoxylin and eosin-stained sections were evaluated for neoplastic invasiveness and cell morphology, necrosis within the neoplasm, inflammation, and glaucoma. Sections were immunolabeled with antibodies against melan-A, PNL2, E-cadherin, or B-Raf, and label intensity, percentage of labeled cells, and label homogeneity were semi-quantitatively graded. Medical records were evaluated, and referring veterinarians and clients were contacted to determine whether cats developed metastasis following enucleation. The log-rank test or Cox proportional hazards model was used to determine associations between histologic or immunohistochemical parameters and metastasis. Metastasis was suspected or confirmed in 9/47 (19%) cats. Extrascleral extension, necrosis within the neoplasm, a mitotic index of >7 mitoses in 10 high-power (×400) fields, choroidal invasion, and increased E-cadherin and melan-A label intensity were each associated with increased rate of metastasis. PNL2 label homogeneity was associated with decreased rate of metastasis. Decreased PNL2 label intensity and an increasing percentage of neoplastic cells labeled for melan-A each approached significance for increased rate of metastasis. We report four histologic and three immunohistochemical parameters helpful in determining cats at risk of metastasis of FDIM. Further studies should determine if B-Raf mutations identified in human malignant melanomas are found in cats with FDIM and assess benefits of adjunctive therapy following enucleation of eyes with FDIM bearing poor prognostic indicators. © 2016 American College of Veterinary Ophthalmologists.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Becker, J.M.
A preliminary survey of selected structures on the Hanford Site for Townsend`s big-wed bat (Plecotus townsendii) was conducted by Pacific Northwest Laboratory (PNL) in August and September 1993. The Westinghouse Hanford Company (WHC) commissioned PNL to evaluate the potential for this bat, a candidate for federal protection, to occur in buildings potentially affected by decontamination and decommissioning operations under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). The project involved identifying structures that contained bats and determining whether Townsend`s big-eared bats were among those present. The survey focused on deactivated reactors, other buildings in the 100D and 100K Areas,more » canyon buildings in the 200 Areas, and other structures reported to contain bats. During this six-week survey, Townsend`s big-wed bat was not located. However, some structures likely to contain bat colonies were unable to be surveyed and others were only partially surveyed. These require further investigation over a longer period of time before a final determination on this species can be made. Of the buildings surveyed, the reactors and their associated buildings provided roosting sites most used by bats. No bats were found in canyon buildings in the 200 areas. These buildings are occupied, well-lighted, and offer few entrances for bats. They are also probably too distant from the Columbia River Shoreline, which constitutes the most important bat foraging habitat. We recommend that the remaining reactors and buildings, with emphasis on subterranean tunnels and basements, be surveyed during a more extended time period, i.e., June through September 1994.« less
Hassan, Mohammed; El-Nahas, Ahmed R; Sheir, Khaled Z; El-Tabey, Nasr A; El-Assmy, Ahmed M; Elshal, Ahmed M; Shokeir, Ahmed A
2015-09-01
To compare the efficacy, safety and cost of extracorporeal shockwave lithotripsy (ESWL) and percutaneous nephrolithotomy (PNL) for treating a 20-30 mm single renal pelvic stone. The computerised records of patients who underwent PNL or ESWL for a 20-30 mm single renal pelvic stone between January 2006 and December 2012 were reviewed retrospectively. Patients aged <18 years who had a branched stone, advanced hydronephrosis, a solitary kidney, anatomical renal abnormality, or had a surgical intervention within the past 6 months were excluded. The study included 337 patients with a mean (SD, range) age of 49.3 (12.2, 20-81) years. The patients' criteria (age, sex, body mass index) and the stone characteristics (side, stone length, surface area, attenuation value and skin-to-stone distance) were compared between the groups. The re-treatment rate, the need for secondary procedures, success rate, complications and the total costs were calculated and compared. In all, 167 patients were treated by ESWL and 170 by PNL. The re-treatment rate (75% vs. 5%), the need for secondary procedures (25% vs. 4.7%) and total number of procedures (three vs. one) were significantly higher in the ESWL group (P < 0.001). The success rate was significantly higher in the PNL group (95% vs. 75%, P < 0.001), as was the complication rate (13% vs. 6.6%, P = 0.050). The total costs of primary and secondary procedures were significantly higher for PNL (US$ 1120 vs. 490; P < 0.001). PNL was more effective than ESWL for treating a single renal pelvic stone of 20-30 mm. However, ESWL was associated with fewer complications and a lower cost.
Parim, BrahmaNaidu; Harishankar, Nemani; Balaji, Meriga; Pothana, Sailaja; Sajjalaguddam, Ramgopal Rao
2015-01-01
Piper nigrum Linn (Piperaceae) (PnL) is used in traditional medicine to treat gastric ailments, dyslipidemia, diabetes, and hypertension. The present study explores the possible protective effects of P. nigrum extracts on high-fat diet-induced obesity in rats. High-fat diet-induced obese rats were treated orally with 200 mg/kg bw of different extracts (hexane, ethylacetate, ethanol, and aqueous extracts) of PnL for 42 d. The effects of PnL extracts on body composition, insulin resistance, biochemical parameters, leptin, adiponectin, lipid profile, liver marker enzymes, and antioxidants were studied. The HFD control group rats showed a substantial raise in body weight (472.8 ± 9.3 g), fat% (20.8 ± 0.6%), and fat-free mass (165.9 ± 2.4 g) when compared with normal control rats whose body weight, fat%, and fat-free mass were 314.3 ± 4.4 g, 6.4 ± 1.4%, and 133.8 ± 2.2 g, respectively. Oral administration of ethyl acetate or aqueous extracts of PnL markedly reduced the body weight, fat%, and fat-free mass of HFD-fed rats. In contrast to the normal control group, a profound increase in plasma glucose, insulin resistance, lipid profile, leptin, thiobarbituric acid reactive substance (TBARS), and the activities of lipase and liver marker enzymes, and a decrease in adiponectin and antioxidant enzymes were noted in HFD control rats. Administration of PnL extracts to HFD-induced obese rats significantly (p < 0.05) restored the above profiles. PnL extracts significantly reduced the body weight, fat%, and ameliorated HFD-induced hyperlipidemia and its constituents.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hu, T.A.
This is the final sample analysis report for tank 241-BX-104 (BX-104), cores 126 and 127. Two segments from each core yielded a total of 11 samples which were analyzed. The data quality objectives (DQOs) applicable to this sampling event were the Safety Screening DQO (Dukelow et al. 1995) and the Organic Safety DQO (Turner et al. 1995). The samples were received, extruded and analyzed at PNNL 325 Analytical Chemistry Laboratory (ACL). The analyses were performed in accordance with the Sample Analysis Plan (Gretsinger 1996) and indicated that the tank is safe with respect to the criteria in the Safety Screeningmore » and Organic DQO. Detailed analytical results were described in the analytical laboratory 45-day Report (Attachment 1, WHC-SD-WM-DP-171, REV. 0) and final report (Attachment 2, PNL-BX-104 REV.1) prepared by PNNL, 325 Laboratory. Corrections and/or exceptions to the PNNL final report are provided.« less
Miriagou, V.; Papagiannitsis, C. C.; Kotsakis, S. D.; Loli, A.; Tzelepi, E.; Legakis, N. J.; Tzouvelekis, L. S.
2010-01-01
The nucleotide sequence of pNL194, a VIM-1-encoding plasmid, is described in this study. pNL194 (79,307 bp) comprised an IncN-characteristic segment (38,940 bp) and a mosaic structure (40,367 bp) including blaVIM-1, aacA7, aadA1, aadA2, dfrA1, dfrA12, aphA1, strA, strB, and sul1. Tn1000 or Tn5501 insertion within fipA probably facilitated recruitment of additional mobile elements carrying resistance genes. PMID:20660690
Evidence of lung cancer risk from animal studies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cross, F.T.
Human epidemiological data provide the most important basis for assessing risks of radon exposures. However, additional insight into the nature of exposure-response relationships is provided by animal experimentation and dosimetric determinations. Animal studies have now been conducted for more than 50 years to examine the levels of pollutants in underground mines that were responsible for the respiratory effects observed among miners. This work has emphasized respiratory cancer and the interaction of radon with other agents, such as ore dust, diesel-engine-exhaust fumes and cigarette smoke. The more recent data on radon-daughter inhalation exposures were provided by two American research centers, Themore » University of Rochester (UR) and the Pacific Northwest Laboratory (PNL), and by the Compagnie Generale des Matieres Nucleaires (COGEMA) laboratory in France. Approximately 2000 mice, 100 rats and 80 dogs were employed in the completed UR studies, begun in the mid 1950s; 800 hamsters, 5000 rats and 100 dogs in the ongoing PNL studies, begun in the late 1960s; and 10,000 rats in the ongoing COGEMA studies, also begun in the late 1960s. More complete updated biological effects, data resulting from chronic radon-daughter inhalation exposures of mice, hamsters, rats and beagle dogs were examined. Emphasis on the carcinogenic effects of radon-decay product exposure, including the influences of radon-daughter exposure rate, unattached fraction and disequilibrium, and co-exposures to other pollutants. Plausible values for the radon (radon-daughter) lifetime lung-cancer risk coefficients are also provided. 13 refs., 1 fig., 1 tab.« less
Soil type influences the sensitivity of nutrient dynamics to changes in atmospheric CO2
USDA-ARS?s Scientific Manuscript database
Numerous studies have indicated that increases in atmospheric CO2 have the potential to decrease nitrogen availability through the process of progressive nitrogen limitation (PNL). The timing and magnitude of PNL in field experiments is varied due to numerous ecosystem processes. Here we examined ...
Soil type influences the sensitivity of nutrient dynamics to changes in atmospheric CO2
USDA-ARS?s Scientific Manuscript database
Numerous studies have indicated that increases in atmospheric CO2 have the potential to decrease nitrogen availability through the process of progressive nitrogen limitation (PNL). The timing and magnitude of PNL in field experiments is varied due to numerous ecosystem processes. Here we examined th...
DELFT3D-Modelling of Hydrodynamic and Water Quality Processes in San Diego Bight
2009-01-01
Terrill (SIO Scripps), Dr. Lyle Hibler ( PNL ) and Mark Moline (CalPoly) who are funded separately. LONG-TERM GOALS The long-term goal of this...cooperation with Dr. Eric Terrill (SIO Scripps), Dr. Lyle Hibler ( PNL ) and Mark Moline (CalPoly) who are funded separately.
Estimating Bodywave Arrivals and Attenuation from Seismic Noise
2009-09-30
power) and Figure 3d the standardized site amplification terms from Savage and Helmberger (2004) who used the Pnl ratio of vertical to radial energy...incident Pnl waves, Bull. Seismol. Soc. Am. 94: 357-362. Shearer, P. (1997). Improving local earthquake locations using the LI norm and waveform
Pacific Northwest Laboratory Annual Report for 1992 to the DOE Office of Energy Research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kreml, S.A.; Park, J.F.
1993-06-01
This report summarizes progress in OHER biological research and general life sciences research programs conducted at PNL in FY 1992. The research develops the knowledge and fundamental principles necessary to identify, understand, and anticipate the long-term health consequences of energy-related radiation and chemicals. Our continuing emphasis is to decrease the uncertainty of health risk estimates from energy-related technologies through an increase understanding of the ways in which radiation and chemicals cause biological damage. Descriptors of individual research projects as detailed in this report one separately abstracted and indexed for the database.
NASA Astrophysics Data System (ADS)
Chandrashekar, Anand; Chen, Feng; Lin, Jasmine; Humayun, Raashina; Wongsenakhum, Panya; Chang, Sean; Danek, Michal; Itou, Takamasa; Nakayama, Tomoo; Kariya, Atsushi; Kawaguchi, Masazumi; Hizume, Shunichi
2010-09-01
This paper describes electrical testing results of new tungsten chemical vapor deposition (CVD-W) process concepts that were developed to address the W contact and bitline scaling issues on 55 nm node devices. Contact resistance (Rc) measurements in complementary metal oxide semiconductor (CMOS) devices indicate that the new CVD-W process for sub-32 nm and beyond - consisting of an advanced pulsed nucleation layer (PNL) combined with low resistivity tungsten (LRW) initiation - produces a 20-30% drop in Rc for diffused NiSi contacts. From cross-sectional bright field and dark field transmission electron microscopy (TEM) analysis, such Rc improvement can be attributed to improved plugfill and larger in-feature W grain size with the advanced PNL+LRW process. More experiments that measured contact resistance for different feature sizes point to favorable Rc scaling with the advanced PNL+LRW process. Finally, 40% improvement in line resistance was observed with this process as tested on 55 nm embedded dynamic random access memory (DRAM) devices, confirming that the advanced PNL+LRW process can be an effective metallization solution for sub-32 nm devices.
Dağgülli, Mansur; Sancaktutar, Ahmet Ali; Dede, Onur; Utanğaç, Mehmet Mazhar; Bodakçi, Mehmet Nuri; Penbegül, Necmettin; Hatipoğlu, Namık Kemal; Çakmakçı, Süleyman
2015-11-01
We aimed to present the outcomes of PNL surgery performed in infantile patients with small renal stones who were younger than 1 year of age. A single-center prospective trial was initiated and during the period between Jan 2013 and Jan 2015, PNL was applied to 20 renal units of 16 infants (6 girls and 10 boys), including 4 patients with bilateral kidney stones. PNL was performed in patients with renal stones larger than 2 cm, as well as stones resistant to SWL or renal stones that were undetectable during SWL. The mean age of the patients was 9.55 (5-12) months. Of the 20 renal units, 1 had complete staghorn stones, 3 had partial staghorn stones, 13 had renal pelvic stones, and 3 had lower pole stones. The mean stone size was 18.5 mm (range 12-36 mm). Mean operative time for PNL was 88 (25-135 min). Mean fluoroscopy time was estimated as 3.4 min. Mean hemoglobin loss was 0.72 g/L (0.2-3). The mean hospital stay was 4.1 days (2-8 days). On postoperative day 1, a complete stone-free state was achieved in 70% of renal units (14 of 20). At the end of the first postoperative week, the remaining two patients had insignificant residual fragments of 3 mm and were followed conservatively without any specific intervention. Thus, the total SFR was 80% (16 of 20) at discharge. In infants aged less than 1 year, minimal access tract dilation during PNL, the use of smaller caliber pediatric instruments, and the realization of this procedure by surgeons with adequate experience in adults carry utmost importance. In addition, special care should be taken to avoid hypothermia and radiation exposure during PNL.
Shen, Pengfei; Liu, Yong; Wang, Jia
2012-01-01
Historically, percutaneous nephrostomy drainage following percutaneous nephrolithotomy (PNL) has been considered the standard of care. More recently, however, an increasing number of centers are performing tubeless (with insertion of JJ ureteric stent) or totally tubeless (with no internal or external drainage) PNL with impressive outcome data. This systematic review is to compare the clinical therapeutic efficacy and safety of nephrostomy tube-free (NT-free) and standard PNL. We searched PubMed (1966 to April 2011), Embase (1966 to April 2011), and the Cochrane Library without language restriction. All randomized controlled trials that compared NT-free PNL (using a double-J stent) with standard PNL were enrolled in this review. The Cochrane Collaboration's RevMan5.0.2 software was used for statistical analysis. Nine studies involving 547 patients were included. Patients were divided into 4 groups: NT-free group, small tube group (8-9 Fr), middle tube group (16-18 Fr), and large tube group (20-24 Fr). Meta-analysis showed that: (1) with regard to hospital stay (h) and visual analog scale scores for postoperative pain on day 1, there was no significant difference between the NT-free group and the small tube group, but there were differences between the NT-free group versus the middle and large tube groups; (2) for puncture site urinary leakage, no significant difference was found between the NT-free group and the small and middle tube groups; (3) no significant difference was found with regard to transfusion, fever or infection, operative time between the NT-free group and the 3 tube groups. The clinical efficacy and safety of NT-free and small tube are similar in all measurements. Compared with the middle and large tubes, NT-free PNL could reduce hospital stay and postoperative analgesia requirement without increasing other complications. Copyright © 2012 S. Karger AG, Basel.
Li, Jun; Wang, Wenying; Du, Yuan; Tian, Ye
2018-03-28
We investigated the clinical value of treating pediatric multiple kidney stones with extensive distribution using flexible ureteroscopic lithotripsy (FUL) combined with micro-percutaneous nephrolithotomy (micro-PNL). In total, 21 pediatric patients with multiple renal calculi between May 2016 and June 2017 received FUL combined with micro-PNL. The group included 13 boys and eight girls; the patients' mean age was 3.8 years (range 1-8 years). The maximum stone diameter ranged from 1.0 to 1.5 cm. FUL was first performed in the lithotomy position to fragment stones that were located in the renal pelvis, and upper and mid-renal calyx. Patients were then moved to a prone position, and micro-PNL was performed to treat lower pole stones that could not be reached by the flexible ureteroscope during FUL. Percutaneous renal access to the lower calyx was achieved using a 4.8F "all-seeing needle" with ultrasound guidance, and stone fragmentation was performed with a 200-μm holmium laser at different settings to disintegrate 1- to 2-mm fragments. All 21 pediatric patients with multiple kidney stones underwent combined FUL and micro-PNL. The stone free rate (SFR) was 85.7% (18/21). The mean surgical time was 45 min (range 30-70 min). The mean volume of irrigation fluid used was 480 mL (range 300-1200 mL). The mean surgical time for FUL and micro-PNL was 31 min and 14 min, respectively, and the mean volume of fluid used for FUL and micro-PNL was 360 mL and 120 mL, respectively. According to the modified Clavien classification, grade 1 and 2 postoperative complications occurred in five and one patients, respectively. The mean decrease in the level of hemoglobin was 0.4 g/dL (0-0.7 g/dL), and no patients required a transfusion. The average hospital stay was 3 days (range 2-5 days). Combined FUL and micro-PNL is a safe, effective, and minimally invasive operation to remove multiple renal calculi with extensive distribution in children in selected cases. Copyright © 2018 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Improvements in Intracorporeal Lithotripters for Percutaneous Nephrolithotomy
NASA Astrophysics Data System (ADS)
Kuo, Ramsay L.
2007-04-01
Percutaneous nephrolithotomy (PNL) is an effective minimally invasive surgical approach for the treatment of large renal stone burden. Intracorporeal lithotripters (ICL) are utilized during PNL to fragment calculi, with some devices capable of concurrently removing fragments as well. Much progress has been made in the design of ICL devices, resulting in potentially more efficient treatment of nephrolithiasis.
Benchmarking study of the MCNP code against cold critical experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sitaraman, S.
1991-01-01
The purpose of this study was to benchmark the widely used Monte Carlo code MCNP against a set of cold critical experiments with a view to using the code as a means of independently verifying the performance of faster but less accurate Monte Carlo and deterministic codes. The experiments simulated consisted of both fast and thermal criticals as well as fuel in a variety of chemical forms. A standard set of benchmark cold critical experiments was modeled. These included the two fast experiments, GODIVA and JEZEBEL, the TRX metallic uranium thermal experiments, the Babcock and Wilcox oxide and mixed oxidemore » experiments, and the Oak Ridge National Laboratory (ORNL) and Pacific Northwest Laboratory (PNL) nitrate solution experiments. The principal case studied was a small critical experiment that was performed with boiling water reactor bundles.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keifer, W.S.; Blumenthal, D.L.; Tommerdahl, J.B.
1981-09-01
As part of the EPRI sulfate regional experiment (SURE), Meteorology Research, Inc., (MRI) and Research Triangle Institute (RTI) conducted six air quality sampling programs in the eastern United States using instrumented aircraft. This volume includes the air quality and meteorological data obtained during the July 1978 Intensive when MRI sampled near the Duncan Falls, Ohio, SURE Station and RTI sampled near the Scranton, Pennsylvania, SURE Station. During the last part of the July 1978 sampling period, both MRI and RTI aircraft participated in a large regional-scale sampling program with Brookhaven National Laboratory (BNL) and Pacific Northwest Laboratory (PNL). Only themore » data obtained by the MRI and RTI aircraft during this regional-scale sapling program are included in this volume.« less
Park, Jinsung; Suh, Beomseok; Lee, Myung Shin; Woo, Seung Hyo; Shin, Dong Wook
2016-12-01
Despite high prevalence of upper urinary tract calculi (UUTC), there are few studies regarding patterns of care in Asian populations. We investigated treatment patterns and time trends in patients with newly diagnosed UUTC in Korea using the National Health Insurance database that includes de-identified claims from a random 2% sample of the entire population (> 1 million people). A total of 14,282 patients who received active treatments, including shock wave lithotripsy (SWL), ureteroscopic surgery (URS), percutaneous nephrolithotomy (PNL), and uretero/pyelolithotomy (UPL), for newly diagnosed UUTC between 2003 and 2013 were included. The number of primary and all treated cases of UUTC significantly (43% and 103.3%, respectively) increased over the 10-year period. While patients undergoing SWL, URS, PNL, and UPL as primary treatment increased by 43.7%, 31.9%, 87.5%, and 0%, respectively, the relative proportion undergoing each treatment remained constant over the 10 years (SWL > 90%, URS 4.5% to 7.8%, PNL 0.4% to 1.0%, and UPL < 0.4%, respectively). Multinomial logistic regression analysis showed that age > 40 years (compared to age < 30 years) was significantly associated with URS, PNL, and UPL, rather than SWL, while patients living in urban or suburban/rural areas (compared to metropolitan) were significantly less likely to undergo URS and PNL. In summary, the majority of Korean patients underwent SWL as primary treatment for UUTC, and the predominant use of SWL remained steady over a 10-year period in Korea. Our results will be valuable in examining treatment patterns and time trends in Korean UUTC patients.
Delft3D-Modelling of Hydrodynamic and Water Quality Processes in San Diego Bight
2010-09-30
Terrill (SIO Scripps), Dr. Lyle Hibler ( PNL ) and Mark Moline (CalPoly) who are funded separately. LONG-TERM GOALS The long-term goal of this effort is...October 3, 2002. RELATED PROJECTS This work is a cooperation with Dr. Eric Terrill (SIO Scripps), Dr. Lyle Hibler ( PNL ) and Mark Moline (CalPoly) who are funded separately. 5
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buelt, J.L.; Stottlemyre, J.A.; White, M.K.
1991-09-01
Because of the great complexity and number of potential waste sites facing the US Department of Energy (DOE) for potential cleanup, the DOE is supporting the development of a computer-based methodology to streamline the remedial investigations/feasibility study process required for DOE operable units. DOE operable units are generally more complex in nature because of the existence of multiple waste sites within many of the operable units and the presence of mixed radioactive and hazardous chemical wastes. Consequently, Pacific Northwest Laboratory (PNL) is developing the Remedial Action Assessment System (RAAS), which is aimed at screening, linking, and evaluating establishment technology processmore » options in support of conducting feasibility studies under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). It is also intended to do the same in support of corrective measures studies requires by the Resource Conservation and Recovery Act (RCRA). This paper presents the characteristics of two RAAS prototypes currently being developed. These include the RAAS Technology Information System, which accesses information on technologies in a graphical and tabular manner, and the main RAAS methodology, which screens, links, and evaluates remedial technologies. 4 refs., 3 figs., 1 tab.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buelt, J.L.; Stottlemyre, J.A.; White, M.K.
1991-02-01
Because of the great complexity and number of potential waste sites facing the US Department of Energy (DOE) for potential cleanup, the DOE is supporting the development of a computer-based methodology to streamline the remedial investigation/feasibility study process required for DOE operable units. DOE operable units are generally more complex in nature because of the existence of multiple waste sites within many of the operable units and the presence of mixed radioactive and hazardous chemical wastes. Consequently, Pacific Northwest Laboratory (PNL) is developing the Remedial Action Assessment System (RAAS), which is aimed at screening, linking, and evaluating established technology processmore » options in support of conducting feasibility studies under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). It is also intended to do the same in support of corrective measures studies required by the Resource Conservation and Recovery Act (RCRA). This paper presents the characteristics of two RAAS prototypes currently being developed. These include the RAAS Technology Information System, which accesses information on technologies in a graphical and tabular manner, and the main RAAS methodology, which screens, links, and evaluates remedial technologies. 4 refs., 3 figs., 1 tab.« less
Hydrogen recombiner catalyst test supporting data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Britton, M.D.
1995-01-19
This is a data package supporting the Hydrogen Recombiner Catalyst Performance and Carbon Monoxide Sorption Capacity Test Report, WHC-SD-WM-TRP-211, Rev 0. This report contains 10 appendices which consist of the following: Mass spectrometer analysis reports: HRC samples 93-001 through 93-157; Gas spectrometry analysis reports: HRC samples 93-141 through 93-658; Mass spectrometer procedure PNL-MA-299 ALO-284; Alternate analytical method for ammonia and water vapor; Sample log sheets; Job Safety analysis; Certificate of mixture analysis for feed gases; Flow controller calibration check; Westinghouse Standards Laboratory report on Bois flow calibrator; and Sorption capacity test data, tables, and graphs.
Nonthermal plasma technology for organic destruction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heath, W.O.; Birmingham, J.G.
1995-06-01
Pacific Northwest Laboratory (PNL) is investigating the use of nonthermal, electrically driven plasmas for destroying organic contaminants near ambient temperatures and pressures. Three different plasma systems have been developed to treat organics in air, water, and soil. These systems are the Gas-Phase Corona Reactor (GPCR)III for treating air, the Liquid-Phase Corona Reactor for treating water, and In Situ Corona for treating soils. This presentation focuses on recent technical developments, commercial status, and project costs of OPCR as a cost-effective alternative to other air-purification technologies that are now in use to treat off-gases from site-remediation efforts as well as industrial emissions.
Requirements Analysis for the Army Safety Management Information System (ASMIS)
1989-03-01
8217_>’ Telephone Number « .. PNL-6819 Limited Distribution Requirements Analysis for the Army Safety Management Information System (ASMIS) Final...PNL-6819 REQUIREMENTS ANALYSIS FOR THE ARMY SAFETY MANAGEMENT INFORMATION SYSTEM (ASMIS) FINAL REPORT J. S. Littlefield A. L. Corrigan March...accidents. This accident data is available under the Army Safety Management Information System (ASMIS) which is an umbrella for many databases
The patient position for PNL: does it matter?
Cracco, Cecilia Maria; Scoffone, Cesare Marco; Poggio, Massimiliano; Scarpa, Roberto Mario
2010-03-01
Currently, PNL is the treatment of choice for large and/or otherwise complex urolithiasis. PNL was initially performed with the patient in a supine-oblique position, but later on the prone position became the conventional one for habit and handiness. The prone position provides a larger area for percutaneous renal access, a wider space for instrument manipulation, and a claimed lower risk of splanchnic injury. Nonetheless, it implies important anaesthesiological risks, including circulatory, haemodynamic, and ventilatory difficulties; need of several nurses to be present for intraoperative changes of the decubitus in case of simultaneous retrograde instrumentation of the ureter, implying evident risks related to pressure points; an increased radiological hazard to the urologist's hands; patient discomfort. To overcome these drawbacks, various safe and effective changes in patient positioning for PNL have been proposed over the years, including the reverse lithotomy position, the prone split-leg position, the lateral decubitus, the supine position, and the Galdakao-modified supine Valdivia (GMSV) position. Among these, the GMSV position is safe and effective, and seems profitable and ergonomic. It allows optimal cardiopulmonary control during general anaesthesia; an easy puncture of the kidney; a reduced risk of colonic injury; simultaneous antero-retrograde approach to the renal cavities (PNL and retrograde ureteroscopy = ECIRS, Endoscopic Combined IntraRenal Surgery), with no need of intraoperative repositioning of the anaesthetized patient, less need for nurses in the operating room, less occupational risk due to shifting of heavy loads, less risk of pressure injuries related to inaccurate repositioning, and reduced duration of the procedure; facilitated spontaneous evacuation of stone fragments; a comfortable sitting position and a restrained X-ray exposure of the hands for the urologist. But, first of all, GMSV position fully supports a new comprehensive attitude of the urologist towards a variety of upper urinary tract pathologies, facing them with a rich armamentarium of rigid and flexible endoscopes and a versatile antero-retrograde approach. Prone position may still be useful in case of important vertebral malformations, specifically hindering the supine position, or for simultaneous bilateral PNL, without having to move the patient intraoperatively, so is still present in the complementary techniques of a skilled endourologist.
Day care PNL using 'Santosh-PGI hemostatic seal' versus standard PNL: A randomized controlled study.
Kumar, Santosh; Singh, Shivanshu; Singh, Prashant; Singh, Shrawan Kumar
2016-01-01
To compare the outcomes of tubeless day care PNL using hemostatic seal in the access tract versus standard PNL. It was a prospective randomized controlled study. Cases were randomized to either the day care group with hemostatic seal (DCS) or the control group where patients were admitted and a nephrostomy tube was placed at the conclusion of surgery. A total of 180 cases were screened and out of these, 113 were included in the final analysis. The stone clearance rates were comparable in both the groups. The mean drop in hemoglobin was significantly lower in DCS group than the control group (1.05 ±0.68 vs. 1.30 ±0.58 gm/dl, p = 0.038).Mean postoperative pain score, analgesic requirement (paracetamol) and duration of hospital stay were also significantly lower in the DCS group (3.79 ±1.23 vs. 6.12 ±0.96, 1.48 ±0.50 vs. 4.09 ±1.11 grams and 0.48 ±0.26 vs. 4.74 ±1.53 days respectively; p <0.05). The incidence of urine leakage through the access tract site was significantly lower in the DCS subgroup when compared to the controls (3.6% vs. 21.1%, p <0.05). Cases in the DCS group resumed their normal activities in a significantly shorter time (8.05 ±3.05 vs.18.42 ±4.42 days; p <0.05). Higher proportion of cases in the DCS group got re-admitted, although it was not a statistically significant number (7.1% vs. 1.8%; p = 0.21). Tubeless day care PNL with composite hemostatic tract seal is considered safe. It resulted in a significant reduction of blood loss and analgesic requirement with significantly reduced hospital stay, nephrostomy tube site morbidity and time required to resume normal activity when compared to the standard PNL. However, patients must be compliant with the given instructions and should have access to a health care facility, as few of them may need re-admission.
Day care PNL using ‘Santosh-PGI hemostatic seal’ versus standard PNL: A randomized controlled study
Singh, Shivanshu; Singh, Prashant; Singh, Shrawan Kumar
2016-01-01
Introduction To compare the outcomes of tubeless day care PNL using hemostatic seal in the access tract versus standard PNL. Material and methods It was a prospective randomized controlled study. Cases were randomized to either the day care group with hemostatic seal (DCS) or the control group where patients were admitted and a nephrostomy tube was placed at the conclusion of surgery. Results A total of 180 cases were screened and out of these, 113 were included in the final analysis. The stone clearance rates were comparable in both the groups. The mean drop in hemoglobin was significantly lower in DCS group than the control group (1.05 ±0.68 vs. 1.30 ±0.58 gm/dl, p = 0.038).Mean postoperative pain score, analgesic requirement (paracetamol) and duration of hospital stay were also significantly lower in the DCS group (3.79 ±1.23 vs. 6.12 ±0.96, 1.48 ±0.50 vs. 4.09 ±1.11 grams and 0.48 ±0.26 vs. 4.74 ±1.53 days respectively; p <0.05). The incidence of urine leakage through the access tract site was significantly lower in the DCS subgroup when compared to the controls (3.6% vs. 21.1%, p <0.05). Cases in the DCS group resumed their normal activities in a significantly shorter time (8.05 ±3.05 vs.18.42 ±4.42 days; p <0.05). Higher proportion of cases in the DCS group got re-admitted, although it was not a statistically significant number (7.1% vs. 1.8%; p = 0.21). Conclusions Tubeless day care PNL with composite hemostatic tract seal is considered safe. It resulted in a significant reduction of blood loss and analgesic requirement with significantly reduced hospital stay, nephrostomy tube site morbidity and time required to resume normal activity when compared to the standard PNL. However, patients must be compliant with the given instructions and should have access to a health care facility, as few of them may need re-admission. PMID:27551557
Ozgor, Faruk; Yanaral, Fatih; Savun, Metin; Ozdemir, Harun; Caglar, Ufuk; Sarilar, Omer
2018-06-01
Life expectancy has become longer, thus the number of elderly people who require treatment for nephrolithiasis has increased. We aimed to analyze the efficacy of flexible ureterorenoscopy (f-URS) and miniaturized percutaneous nephrolithotomy (mPNL) in the management of 10 and 30 mm renal stones in patients aged >60 years. In prospective non-randomized series, the data of patients who underwent f-URS or mPNL for kidney stones between July 2013 and July 2016 were analyzed. The procedure was accepted as successful if the patient was achieved complete stone clearance according to CT imaging between 1-3 months postoperatively. In total 60 patients and 58 patients were underwent f-URS and mPNL, respectively. The mean operation time, fluoroscopy time and hospitalization time were significantly shorter for the f-URS (p < 0.001, p < 0.001, p < 0.001, respectively). According to Clavien classification system, complication rates were not significantly different between the groups (p = 0.673). The stone-free rate was 81.7% for the f-URS group and 77.6% for the mPNL group after a single-session procedure (p = 0.747). Calcium oxalate monohydrate stones were the most common stone type in both groups. In multivariate analysis, multiple stones localization was only independent factor to predict complications. Our study had showed that both f-URS and mPNL are effective treatment modalities for 10-30-mm renal stones in elderly patients. Additionally, presence of stones in multiple location was the only predictive factor for complication development. Copyright © 2017 Kaohsiung Medical University. Published by Elsevier Taiwan. All rights reserved.
Liu, Y; Chatterjee, A; Chatterjee, A K
1994-12-01
In most soft-rotting Erwinia spp., including E. carotovora subsp. carotovora strain 71 (Ecc71), production of the plant cell wall degrading enzyme pectin lyase (Pnl) is activated by DNA-damaging agents such as mitomycin C (MC). Induction of Pnl production in Ecc71 requires a functional recA gene and the rdg locus. DNA sequencing and RNA analyses revealed that the rdg locus contains two regulatory genes, rdgA and rdgB, in separate transcriptional units. There is high homology between RdgA and repressors of lambdoid phages, specially phi 80. RdgB, however, has significant homology with transcriptional activators of Mu phage. Both RdgA and RdgB are also predicted to possess helix-turn-helix motifs. By replacing the rdgB promoter with the IPTG-inducible tac promoter, we have determined that rdgB by itself can activate Pnl production in Escherichia coli. However, deletion analysis of rdg+ DNA indicated that, when driven by their native promoters, functions of both rdgA and rdgB are required for the induction of pnlA expression by MC treatment. While rdgB transcription occurs only after MC treatment, a substantial level of rdgA mRNA is detected in the absence of MC treatment. Moreover, upon induction with MC, a new rdgA mRNA species, initiated from a different start site, is produced at a high level. Thus, the two closely linked rdgA and rdgB genes, required for the regulation of Pnl production, are expressed differently in Ecc71.
Durantel, D; Croizier, L; Ayres, M D; Croizier, G; Possee, R D; López-Ferber, M
1998-03-01
Autographa californica nucleopolyhedrovirus (AcMNPV) ORF 86, located within the HindIII C fragment, potentially encodes a protein which shares sequence similarity with two T4 bacteriophage gene products, RNA ligase and polynucleotide kinase. This AcMNPV gene has been designated pnk/pnl but has yet to be assigned a function in virus replication. It has been classified as an immediate early virus gene, since the promoter was active in uninfected insect cells and mRNA transcripts were detectable from 4 to 48 h post-infection and in the presence of cycloheximide or aphidicolin in virus-infected cells. The extremities of the transcript have been mapped by primer extension and 3' RACE-PCR to positions -18 from the translational start codon and +15 downstream of the stop codon. The function of pnk/pnl was investigated by producing a recombinant virus (Acdel86lacZ) with the coding region replaced with that of lacZ. This virus replicated normally in Spodoptera frugiperda (Sf 21) cells, indicating that pnk/pnl is not essential for propagation in these cells. Virus protein production in Acdel86lacZ-infected Sf 21 cells also appeared to be unaffected, with normal synthesis of the IE-1, GP64, VP39 and polyhedrin proteins. Shut-down of host protein synthesis was not abolished in recombinant infection. When other baculovirus genomes were examined for the presence of pnk/pnl by restriction enzyme digestion and PCR, a deletion was found in AcMNPV 1.2, Galleria mellonella NPV (GmMNPV) and Bombyx mori NPV (BmNPV), suggesting that in many isolates this gene has either never been acquired or has been lost during genome evolution. This is one of the first baculovirus immediate early genes that appears to be nonessential for virus survival.
Seckiner, Ilker; Erturhan, Sakip M.; Mizrak, Sedat; Erbagci, Ahmet
2012-01-01
Purpose We aimed to analyze the changes in kidney function during the postoperative early period caused by the application of percutaneous nephrolithotomy (PNL), which is commonly used in kidney stone surgery. Materials and Methods PNL was performed in 80 patients (48 men, 32 women) with kidney stones. The mean age of the patients was 43.71 years (range, 18 to 71 years). Preoperative and postoperative values for stone size, glomerular filtration rate (GFR), serum creatinine, urea, electrolytes (Na, K, Cl), and Hb were compared in 80 patients in whom PNL surgery was performed. The formula of Cockroft-Gault was used to calculate the GFR during the early postoperative period (72 to 96 hours). Results Statistically significant decreases after PNL were observed in average stone size (preoperative, 627.75±375.10 mm2; postoperative, 81.70±16.15 mm2), serum urea (preoperative, 38.40±17.26 mg/dl; postoperative, 33.28±16.98 mg/dl), and creatinine (preoperative, 1.03±0.53 mg/dl; postoperative, 0.97±0.55 mg/dl) and an increase was observed in GFR (preoperative, 104.30±37.30 ml/min; postoperative, 112.38±40.1 ml/min). No changes were detected in the serum electrolyte values (Na, K, Cl). Multiple access, operation time, and type of lithotripter did not have any significant effects on the change in the GFR. Conclusions In light of our results, PNL for kidney stone operations appears to be a reliable and efficient method that provides recovery of kidney functions in the early post-operative period by increasing the GFR and with high stone-free rates. PMID:22950000
Processes regulating progressive nitrogen limitation under elevated carbon dioxide: a meta-analysis
NASA Astrophysics Data System (ADS)
Liang, Junyi; Qi, Xuan; Souza, Lara; Luo, Yiqi
2016-05-01
The nitrogen (N) cycle has the potential to regulate climate change through its influence on carbon (C) sequestration. Although extensive research has explored whether or not progressive N limitation (PNL) occurs under CO2 enrichment, a comprehensive assessment of the processes that regulate PNL is still lacking. Here, we quantitatively synthesized the responses of all major processes and pools in the terrestrial N cycle with meta-analysis of CO2 experimental data available in the literature. The results showed that CO2 enrichment significantly increased N sequestration in the plant and litter pools but not in the soil pool, partially supporting one of the basic assumptions in the PNL hypothesis that elevated CO2 results in more N sequestered in organic pools. However, CO2 enrichment significantly increased the N influx via biological N fixation and the loss via N2O emission, but decreased the N efflux via leaching. In addition, no general diminished CO2 fertilization effect on plant growth was observed over time up to the longest experiment of 13 years. Overall, our analyses suggest that the extra N supply by the increased biological N fixation and decreased leaching may potentially alleviate PNL under elevated CO2 conditions in spite of the increases in plant N sequestration and N2O emission. Moreover, our syntheses indicate that CO2 enrichment increases soil ammonium (NH4+) to nitrate (NO3-) ratio. The changed NH4+/NO3- ratio and subsequent biological processes may result in changes in soil microenvironments, above-belowground community structures and associated interactions, which could potentially affect the terrestrial biogeochemical cycles. In addition, our data synthesis suggests that more long-term studies, especially in regions other than temperate ones, are needed for comprehensive assessments of the PNL hypothesis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, J.F.
1988-02-01
This report summarizes progress on OHER biomedical and health-effects research conducted at Pacific Northwest Laboratory in FY 1987. The research develops the knowledge and scientific principles necessary to identify, understand, and anticipate the long-term health consequences of energy-related radiation and chemicals. Our continuing emphasis is to decrease the uncertainty of health-effects risk estimates from existing and/or developing energy-related technologies through an increased understanding of how radiation and chemicals cause health effects. The report is arranged to reflect PNL research relative to OHER programmatic structure. The first section, on human health effects, concerns statistical and epidemiological studies for assessing health risks.more » The next section, which contains reports of health-effects research in biological systems, includes research with radiation and chemicals. The last section is related to medical applications of nuclear technology.« less
Assessing waveform predictions of recent three-dimensional velocity models of the Tibetan Plateau
NASA Astrophysics Data System (ADS)
Bao, Xueyang; Shen, Yang
2016-04-01
Accurate velocity models are essential for both the determination of earthquake locations and source moments and the interpretation of Earth structures. With the increasing number of three-dimensional velocity models, it has become necessary to assess the models for accuracy in predicting seismic observations. Six models of the crustal and uppermost mantle structures in Tibet and surrounding regions are investigated in this study. Regional Rayleigh and Pn (or Pnl) waveforms from two ground truth events, including one nuclear explosion and one natural earthquake located in the study area, are simulated by using a three-dimensional finite-difference method. Synthetics are compared to observed waveforms in multiple period bands of 20-75 s for Rayleigh waves and 1-20 s for Pn/Pnl waves. The models are evaluated based on the phase delays and cross-correlation coefficients between synthetic and observed waveforms. A model generated from full-wave ambient noise tomography best predicts Rayleigh waves throughout the data set, as well as Pn/Pnl waves traveling from the Tarim Basin to the stations located in central Tibet. In general, the models constructed from P wave tomography are not well suited to predict Rayleigh waves, and vice versa. Possible causes of the differences between observed and synthetic waveforms, and frequency-dependent variations of the "best matching" models with the smallest prediction errors are discussed. This study suggests that simultaneous prediction for body and surface waves requires an integrated velocity model constructed with multiple seismic waveforms and consideration of other important properties, such as anisotropy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Snyder, Sandra F.; Moleta, Donna Grace L.; Meier, Kirsten M.
This is the second revision of the DQO Supporting Radiological Air Emissions Monitoring for the Pacific Northwest National Laboratory Richland Campus. In January 2017, the PNNL Richland Campus expanded to the north by 0.35 km 2 (85.6 acres). Under the requirements of Washington State Department of Health Radioactive Air Emissions License (RAEL)-005, the PNNL Campus operates and maintains a radiological air monitoring program. This revision documents and evaluates the newly acquired acreage while also removing recreational land at the southwest, and also re-examines all active radioactive emission units on the PNNL Campus. No buildings are located on this new Campusmore » land, which was transferred from the U.S. DOE Hanford Site. Additionally, this revision includes information regarding the background monitoring station PNL-5 in Benton City, Washington, which became active in October 2016. The key purpose of this revision is to determine the adequacy of the existing environmental surveillance stations to monitor radiological air emissions in light of this northern boundary change.« less
Percutaneous Nephrolithotomy in Children
DeMarco, Romano T.
2011-01-01
The surgical management of pediatric stone disease has evolved significantly over the last three decades. Prior to the introduction of shockwave lithotripsy (SWL) in the 1980s, open lithotomy was the lone therapy for children with upper tract calculi. Since then, SWL has been the procedure of choice in most pediatric centers for children with large renal calculi. While other therapies such as percutaneous nephrolithotomy (PNL) were also being advanced around the same time, PNL was generally seen as a suitable therapy in adults because of the concerns for damage in the developing kidney. However, recent advances in endoscopic instrumentation and renal access techniques have led to an increase in its use in the pediatric population, particularly in those children with large upper tract stones. This paper is a review of the literature focusing on the indications, techniques, results, and complications of PNL in children with renal calculi. PMID:22013438
Description of the process used to create 1992 Hanford Morality Study database
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilbert, E.S.; Buchanan, J.A.; Holter, N.A.
1992-12-01
An updated and expanded database for the Hanford Mortality Study has been developed by PNL`s Epidemiology and Biometry Department. The purpose of this report is to document this process. The primary sources of data were the Occupational Health History (OHH) files maintained by the Hanford Environmental Health Foundation (HEHF) and including demographic data and job histories; the Hanford Mortality (HMO) files also maintained by HEHF and including information of deaths of Hanford workers; the Occupational Radiation Exposure (ORE) files maintained by PNL`s Health Physics Department and containing data on external dosimetry; and a file of workers with confirmed internal depositionsmore » of radionuclides also maintained by PNL`s Health Physics Department. This report describes each of these files in detail, and also describes the many edits that were performed to address the consistency and accuracy of data within and between these files.« less
Description of the process used to create 1992 Hanford Morality Study database
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilbert, E. S.; Buchanan, J. A.; Holter, N. A.
1992-12-01
An updated and expanded database for the Hanford Mortality Study has been developed by PNL's Epidemiology and Biometry Department. The purpose of this report is to document this process. The primary sources of data were the Occupational Health History (OHH) files maintained by the Hanford Environmental Health Foundation (HEHF) and including demographic data and job histories; the Hanford Mortality (HMO) files also maintained by HEHF and including information of deaths of Hanford workers; the Occupational Radiation Exposure (ORE) files maintained by PNL's Health Physics Department and containing data on external dosimetry; and a file of workers with confirmed internal depositionsmore » of radionuclides also maintained by PNL's Health Physics Department. This report describes each of these files in detail, and also describes the many edits that were performed to address the consistency and accuracy of data within and between these files.« less
ARRAYS OF BOTTLES OF PLUTONIUM NITRATE SOLUTION
DOE Office of Scientific and Technical Information (OSTI.GOV)
Margaret A. Marshall
2012-09-01
In October and November of 1981 thirteen approaches-to-critical were performed on a remote split table machine (RSTM) in the Critical Mass Laboratory of Pacific Northwest Laboratory (PNL) in Richland, Washington using planar arrays of polyethylene bottles filled with plutonium (Pu) nitrate solution. Arrays of up to sixteen bottles were used to measure the critical number of bottles and critical array spacing with a tight fitting Plexiglas® reflector on all sides of the arrays except the top. Some experiments used Plexiglas shells fitted around each bottles to determine the effect of moderation on criticality. Each bottle contained approximately 2.4 L ofmore » Pu(NO3)4 solution with a Pu content of 105 g Pu/L and a free acid molarity H+ of 5.1. The plutonium was of low 240Pu (2.9 wt.%) content. These experiments were sponsored by Rockwell Hanford Operations because of the lack of experimental data on the criticality of arrays of bottles of Pu solution such as might be found in storage and handling at the Purex Facility at Hanford. The results of these experiments were used “to provide benchmark data to validate calculational codes used in criticality safety assessments of [the] plant configurations” (Ref. 1). Data for this evaluation were collected from the published report (Ref. 1), the approach to critical logbook, the experimenter’s logbook, and communication with the primary experimenter, B. Michael Durst. Of the 13 experiments preformed 10 were evaluated. One of the experiments was not evaluated because it had been thrown out by the experimenter, one was not evaluated because it was a repeat of another experiment and the third was not evaluated because it reported the critical number of bottles as being greater than 25. Seven of the thirteen evaluated experiments were determined to be acceptable benchmark experiments. A similar experiment using uranyl nitrate was benchmarked as U233-SOL-THERM-014.« less
Arustamov, L D; Katibov, M I; Merinov, D S; Gurbanov, Sh Sh; Artemov, A V; Epishov, V A
2017-12-01
Management of patients with large and staghorn stones of a solitary kidney is widely debated among urologists and has not been sufficiently investigated, which determined the relevance of this study. The study comprised 80 patients with large (>20 mm) and staghorn stones of an anatomically or functionally solitary kidney. Of them, 58 patients underwent percutaneous nephrolithotripsy (PNL), and 22 had open surgery. The criterion of the treatment effectiveness was the complete stone clearance or small residual fragments sized less than 3 mm. The safety criterion was the absence of intra- and postoperative complications, according to Clavien-Dindo grading system. The study analyzed the following factors influencing the effectiveness and safety of PNL: the number of accesses; nephroscope diameter; use of a nephroscope sheath; type of lithotripter; size, density, type and composition of the stone. Percutaneous nephrolithotripsy demonstrated statistically significantly better safety results compared with open surgery with comparable effectiveness. Long-term stone recurrence rate after PNL and open surgery was 10.4 and 18.2%, respectively. PNL resulted in a statistically significant improvement in the kidney function while it worsened after open surgery. The effectiveness of PNL depends on the stone type and size and the kind of lithotripter. It was 7.5 times greater for a large stone than for staghorn calculi and 4.6 times higher for stones sized less or equal 45 mm than for those sized > 45 mm. Ultrasonic lithotripter was 2.2 times more effective than another type of lithotripter. The safety of PNL depends on the nephroscope diameter, of a sheath, the number of accesses, the type of lithotripter and the type of stone. Using a 24-Ch nephroscope was 3.6 times safer than that with a diameter greater than 24-Ch; not using a sheath was 3.2 times safer than using it; one access was 3 times safer than at multiple ones; using an ultrasound lithotripter was 2.7 times safer than with another type of lithotripter; treating a large stone was 2.1 times safer than a staghorn stone. The study findings can be used to optimize the treatment of patients with large and staghorn stones of a solitary kidney.
Large-break LOCA, in-reactor fuel bundle Materials Test MT-6A
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilson, C.L.; Hesson, G.M.; Pilger, J.P.
1993-09-01
This is a report on one of a series of experiments to simulates a loss-of-coolant accident (LOCA) using full-length fuel rods for pressurized water reactors (PWR). The experiments were conducted by Pacific Northwest Laboratory (PNL) under the LOCA simulation Program sponsored by the US Nuclear Regulatory Commission (NRC). The major objective of this program was causing the maximum possible expansion of the cladding on the fuel rods from a short-term adiabatic temperature transient to 1200 K (1700 F) leading to the rupture of the cladding; and second, by reflooding the fuel rods to determine the rate at which the fuelmore » bundle is cooled.« less
1995 solid waste 30-year characteristics volume summary
DOE Office of Scientific and Technical Information (OSTI.GOV)
Templeton, K.J.; DeForest, T.J.; Rice, G.I.
1995-10-01
The Hanford Site has been designated by the US Department of Energy (DOE) to store, treat, and dispose of solid waste received from both onsite and offsite generators. This waste is currently or planned to be generated from ongoing operations, maintenance and deactivation activities, decontamination and decommissioning (D&D) of facilities, and environmental restoration (ER) activities. This document, prepared by Pacific Northwest Laboratory (PNL) under the direction of Westinghouse Hanford Company (WHC), describes the characteristics of the waste to be shipped to Hanford`s SWOC. The physical waste forms and hazardous constituents are described for the low-level mixed waste (LLMW) and themore » transuranic - transuranic mixed waste (TW{underscore}TRUM).« less
Processes regulating progressive nitrogen limitation under elevated carbon dioxide: a meta-analysis
NASA Astrophysics Data System (ADS)
Liang, J.; Qi, X.; Souza, L.; Luo, Y.
2015-10-01
Nitrogen (N) cycle has the potential to regulate climate change through its influence on carbon (C) sequestration. Although extensive researches have been done to explore whether or not progressive N limitation (PNL) occurs under CO2 enrichment, a comprehensive assessment of the processes that regulate PNL is still lacking. Here, we quantitatively synthesized the responses of all major processes and pools in terrestrial N cycle with meta-analysis of CO2 experimental data available in the literature. The results showed that CO2 enrichment significantly increased N sequestration in plant and litter pools but not in soil pool. Thus, the basis of PNL occurrence partially exists. However, CO2 enrichment also significantly increased the N influx via biological N fixation, but decreased the N efflux via leaching. In addition, no general diminished CO2 fertilization effect on plant growth over time was observed. Overall, our analyses suggest that the extra N supply by the increased biological N fixation and decreased leaching may potentially alleviate PNL under elevated CO2 conditions. Moreover, our synthesis showed that CO2 enrichment increased soil ammonium (NH4+) but decreased nitrate (NO3-). The different responses of NH4+ and NO3-, and the consequent biological processes, may result in changes in soil microenvironment, community structures and above-belowground interactions, which could potentially affect the terrestrial biogeochemical cycles and the feedback to climate change.
Performance testing of radiobioassay laboratories: In vivo measurements, Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
MacLellan, J.A.; Traub, R.J.; Olsen, P.C.
1990-04-01
A study of two rounds of in vivo laboratory performance testing was undertaken by Pacific Northwest Laboratory (PNL) to determine the appropriateness of the in vivo performance criteria of draft American National Standards Institute (ANSI) standard ANSI N13.3, Performance Criteria for Bioassay.'' The draft standard provides guidance to in vivo counting facilities regarding the sensitivity, precision, and accuracy of measurements for certain categories of commonly assayed radionuclides and critical regions of the body. This report concludes the testing program by presenting the results of the Round Two testing. Testing involved two types of measurements: chest counting for radionuclide detection inmore » the lung, and whole body counting for detection of uniformly distributed material. Each type of measurement was further divided into radionuclide categories as defined in the draft standard. The appropriateness of the draft standard criteria by measuring a laboratory's ability to attain them were judged by the results of both round One and Round Two testing. The testing determined that performance criteria are set at attainable levels, and the majority of in vivo monitoring facilities passed the criteria when complete results were submitted. 18 refs., 18 figs., 15 tabs.« less
Long-term high-level waste technology. Composite report
NASA Astrophysics Data System (ADS)
Cornman, W. R.
1981-12-01
Research and development studies on the immobilization of high-level wastes from the chemical reprocessing of nuclear reactor fuels are summarized. The reports are grouped under the following tasks: (1) program management and support; (2) waste preparation; (3) waste fixation; and (4) final handling. Some of the highlights are: leaching properties were obtained for titanate and tailored ceramic materials being developed at ICPP to immobilize zirconia calcine; comparative leach tests, hot-cell tests, and process evaluations were conducted of waste form alternatives to borosilicate glass for the immobilization of SRP high-level wastes, experiments were run at ANL to qualify neutron activation analysis and radioactive tracers for measuring leach rates from simulated waste glasses; comparative leach test samples of SYNROC D were prepared, characterized, and tested at LLNL; encapsulation of glass marbles with lead or lead alloys was demonstrated on an engineering scale at PNL; a canister for reference Commercial HLW was designed at PNL; a study of the optimization of salt-crete was completed at SRL; a risk assessment showed that an investment for tornado dampers in the interim storage building of the DWPF is unjustified.
Processes regulating progressive nitrogen limitation under elevated carbon dioxide: A meta-analysis
Liang, Junyi; Qi, Xuan; Souza, Lara; ...
2016-05-10
Here, the nitrogen (N) cycle has the potential to regulate climate change through its influence on carbon (C) sequestration. Although extensive research has explored whether or not progressive N limitation (PNL) occurs under CO 2 enrichment, a comprehensive assessment of the processes that regulate PNL is still lacking. Here, we quantitatively synthesized the responses of all major processes and pools in the terrestrial N cycle with meta-analysis of CO 2 experimental data available in the literature. The results showed that CO 2 enrichment significantly increased N sequestration in the plant and litter pools but not in the soil pool, partiallymore » supporting one of the basic assumptions in the PNL hypothesis that elevated CO 2 results in more N sequestered in organic pools. However, CO 2 enrichment significantly increased the N influx via biological N fixation and the loss via N 2O emission, but decreased the N efflux via leaching. In addition, no general diminished CO 2 fertilization effect on plant growth was observed over time up to the longest experiment of 13 years. Overall, our analyses suggest that the extra N supply by the increased biological N fixation and decreased leaching may potentially alleviate PNL under elevated CO 2 conditions in spite of the increases in plant N sequestration and N 2O emission. Moreover, our syntheses indicate that CO 2 enrichment increases soil ammonium (NH 4 +) to nitrate (NO 3 –) ratio. The changed NH 4 +/NO 3 – ratio and subsequent biological processes may result in changes in soil microenvironments, above-belowground community structures and associated interactions, which could potentially affect the terrestrial biogeochemical cycles. In addition, our data synthesis suggests that more long-term studies, especially in regions other than temperate ones, are needed for comprehensive assessments of the PNL hypothesis.« less
Atalay, Hasan Anıl; Canat, Lutfi; Bayraktarlı, Recep; Alkan, Ilter; Can, Osman; Altunrende, Fatih
2017-06-23
We analyzed our stone-free rates of PNL with regard to stone burden and its ratio to the renal collecting system volume. Data of 164 patients who underwent PNL were analyzed retrospectively. Volume segmentation of renal collecting system and stones were done using 3D segmentation software with the images obtained from CT data. Analyzed stone volume (ASV) and renal collecting system volume (RCSV) were measured and the ASV-to-RCSV ratio was calculated after the creation of a 3D surface volume rendering of renal stones and the collecting system. Univariate and multivariate statistical analyses were performed to determine factors affecting stone-free rates; also we assessed the predictive accuracy of the ASV-to-RCSV ratio using the receiving operating curve (ROC) and AUC. The stone-free rate of PNL monotherapy was 53% (164 procedures).The ASV-to-RCSV ratio and calyx number with stones were the most influential predictors of stone-free status (OR 4.15, 95% CI 2.24-7.24, <0.001, OR 2.62, 95% CI 1.38-4.97, p < 0.001, respectively). Other factors associated with the stone-free rate were maximum stone size (p < 0.029), stone surface area (p < 0.010), and stone burden volume (p < 0.001). Predictive accuracy of the ASV-to-RCSV ratio was AUC 0.76. Stone burden volume distribution in the renal collecting system, which is calculated using the 3D volume segmentation method, is a significant determinant of the stone-free rate before PCNL surgery. It could be used as a single guide variable by the clinician before renal stone surgery to predict extra requirements for stone clearance.
Design of helicopter rotors to noise constraints
NASA Technical Reports Server (NTRS)
Schaeffer, E. G.; Sternfeld, H., Jr.
1978-01-01
Results of the initial phase of a research project to study the design constraints on helicopter noise are presented. These include the calculation of nonimpulsive rotor harmonic and broadband hover noise spectra, over a wide range of rotor design variables and the sensitivity of perceived noise level (PNL) to changes in rotor design parameters. The prediction methodology used correlated well with measured whirl tower data. Application of the predictions to variations in rotor design showed tip speed and thrust as having the most effect on changing PNL.
Treatment of small lower pole calculi--SWL vs. URS vs. PNL?
Knoll, Thomas; Tasca, Andrea; Buchholz, Noor P
2011-03-01
According to current guideline recommendations extracorporeal shock wave lithotripsy (SWL) remains the first choice treatment for small and mid-sized renal calculi. However, the results of SWL treatment for lower pole stones can be disappointing whilst more invasive endoscopic modalities, such as flexible ureterorenoscopy (fURS) and percutaneous nephrolithotomy (PNL) are often considered more effective. This article summarizes a point-counterpoint discussion at the 9th eULIS symposium in Como, Italy, and discusses the potential advantages and disadvantages of the different therapeutic approaches.
NASA Technical Reports Server (NTRS)
Olsen, W. A.; Friedman, R.
1973-01-01
Noise data were obtained with a small scale model stationary STOL configuration that used an eight lobe mixer nozzle with deflector mounted above a 32-cm-chord wing section. The factors varied to determine their effect upon the noise were wing flap angle, nozzle shape, nozzle location, deflector configuration, and jet velocity. The noise from the mixer nozzle model was compared to the noise from a model using a circular nozzle of the same area. The mixer nozzle model was quieter at the low to middle frequencies, while the circular nozzle was quieter at high frequencies. The perceived noise level (PNL) was calculated for an aircraft 10 times larger than the model. The PNL at 500 feet for the mixer nozzle turned out to be within 1 db of the PNL for the circular nozzle. For some configurations at highly directional broadband noise, which could be eliminated by changes in nozzle and/or deflector location, occurred below the wing.
Environmental surveillance master sampling schedule
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bisping, L.E.
This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring the onsite drinking water falls outside the scope of the SESP. The Hanford Environmental Health Foundation is responsible for monitoring the nonradiological parameters as defined in the National Drinking Water Standards while PNL conducts the radiological monitoring of themore » onsite drinking water. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize the expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control and reporting. The ground-water sampling schedule identifies ground-water sampling events used by PNL for environmental surveillance of the Hanford Site.« less
Primary Report of Totally Tubeless Percutaneous Nephrolithotomy Despite Pelvi-calyceal Perforations.
Aghamir, Seyed Mohammad Kazem; Salavati, Alborz; Hamidi, Morteza; FallahNejad, Asghar
2017-07-02
Nephrostomy tube insertion and/or a ureteral stent placement is advised when pelvi-calyceal perforations are encountered during percutaneous nephrolithotomy (PNL) nevertheless totally tubeless PNL is a possible exit strategy in percutaneous renal surgery therefore case series on the short term clinical outcomes of noninvasive management of iatrogenic pelvicalyceal perforations encountered during PNL is presented. During retrospective analysis of 1271 PNL procedures, 25 incidents of accidental ureteral catheter/ jj stent dislodgement during first 24 post-operative hours were identified in patient who had pelvi calyceal perforations and had no nephrostomy tube (tubeless). Thirteen patients could not be re-stented nor a nephrostomytube could have been placed for them mainly due to patient refusal or comorbid conditions. The main outcome was rate of successful noninvasive management. Eighteen Patients bearing mucosal tears (grade I trauma) or visible peri-pelvic fat (grade II) successfully recovered without need for ureteral stenting or nephrostomy (72.0%). In seven (28.0%) cases of extension of the perforation into the peri-pelvic fat (grade III), either nephrostomy insertion or JJ stenting was needed for resolution of fever and urinoma. The major limitation was the necessity to exclude patients and manage them in the standard fashion according to clinical guidelines. Iatrogenic perforations of the collecting system are quite diverse in terms of severity that result in different natural histories and not all might need urinary diversion via nephrostomy or ureteral stenting.Low grade perforations may be successfully managed in totally tubeless fashion nevertheless further prospective investigations seem warranted.
Standardized input for Hanford environmental impact statements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Napier, B.A.
1981-05-01
Models and computer programs for simulating the environmental behavior of radionuclides in the environment and the resulting radiation dose to humans have been developed over the years by the Environmental Analysis Section staff, Ecological Sciences Department at the Pacific Northwest Laboratory (PNL). Methodologies have evolved for calculating raidation doses from many exposure pathways for any type of release mechanism. Depending on the situation or process being simulated, different sets of computer programs, assumptions, and modeling techniques must be used. This report is a compilation of recommended computer programs and necessary input information for use in calculating doses to members ofmore » the general public for environmental impact statements prepared for DOE activities to be conducted on or near the Hanford Reservation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burnett, R.A.
A major goal of the Analysis of Large Data Sets (ALDS) research project at Pacific Northwest Laboratory (PNL) is to provide efficient data organization, storage, and access capabilities for statistical applications involving large amounts of data. As part of the effort to achieve this goal, a self-describing binary (SDB) data file structure has been designed and implemented together with a set of basic data manipulation functions and supporting SDB data access routines. Logical and physical data descriptors are stored in SDB files preceding the data values. SDB files thus provide a common data representation for interfacing diverse software components. Thismore » paper describes the various types of data descriptors and data structures permitted by the file design. Data buffering, file segmentation, and a segment overflow handler are also discussed.« less
ReOpt[trademark] V2.0 user guide
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, M K; Bryant, J L
1992-10-01
Cleaning up the large number of contaminated waste sites at Department of Energy (DOE) facilities in the US presents a large and complex problem. Each waste site poses a singular set of circumstances (different contaminants, environmental concerns, and regulations) that affect selection of an appropriate response. Pacific Northwest Laboratory (PNL) developed ReOpt to provide information about the remedial action technologies that are currently available. It is an easy-to-use personal computer program and database that contains data about these remedial technologies and auxiliary data about contaminants and regulations. ReOpt will enable engineers and planners involved in environmental restoration efforts to quicklymore » identify potentially applicable environmental restoration technologies and access corresponding information required to select cleanup activities for DOE sites.« less
Velocity Structure Determination Through Seismic Waveform Modeling and Time Deviations
NASA Astrophysics Data System (ADS)
Savage, B.; Zhu, L.; Tan, Y.; Helmberger, D. V.
2001-12-01
Through the use of seismic waveforms recorded by TriNet, a dataset of earthquake focal mechanisms and deviations (time shifts) relative to a standard model facilitates the investigation of the crust and uppermost mantle of southern California. The CAP method of focal mechanism determination, in use by TriNet on a routine basis, provides time shifts for surface waves and Pnl arrivals independently relative to the reference model. These shifts serve as initial data for calibration of local and regional seismic paths. Time shifts from the CAP method are derived by splitting the Pnl section of the waveform, the first arriving Pn to just before the arrival of the S wave, from the much slower surface waves then cross-correlating the data with synthetic waveforms computed from a standard model. Surface waves interact with the entire crust, but the upper crust causes the greatest effect. Whereas, Pnl arrivals sample the deeper crust, upper mantle, and source region. This natural division separates the upper from lower crust for regional calibration and structural modeling and allows 3-D velocity maps to be created using the resulting time shifts. Further examination of Pnl and other arrivals which interact with the Moho illuminate the complex nature of this boundary. Initial attempts at using the first 10 seconds of the Pnl section to determine upper most mantle structure have proven insightful. Two large earthquakes north of southern California in Nevada and Mammoth Lakes, CA allow the creation of record sections from 200 to 600 km. As the paths swing from east to west across southern California, simple 1-D models turn into complex structure, dramatically changing the waveform character. Using finite difference models to explain the structure, we determine that a low velocity zone is present at the base of the crust and extends to 100 km in depth. Velocity variations of 5 percent of the mantle in combination with steeply sloping edges produces complex waveform variations. Characteristics of this complex propagation appear from the southern Sierra Nevada Mountains, in the west, to Death Valley in the east. The structure does not cross the Garlock fault to the south, but we are unsure of the structures northern extent.
Zhang, J.; Bruton, B. D.; Biles, C. L.
2014-01-01
Didymella bryoniae is an important pathogen of cucurbits worldwide. Virulence factors of D. bryoniae were investigated in regard to fungal growth and the production of cell wall-degrading enzymes, polygalacturonase (PG), pectate lyase (PL), pectin lyase (PNL), β-galactosidase (β-Gal) and cellulase (Cx). Virulence levels of five D. bryoniae isolates were determined by the severity of inoculated cantaloupe fruit decay. The highly virulent isolates had more mycelial growth than the moderately virulent isolates in different media. PG activities produced by the highly virulent isolates in shake cultures and in decayed fruit were greater than those of the moderately virulent isolates. PNL, but not PL, in decayed fruit was higher with the highly virulent isolates compared to the moderately virulent ones. The highly virulent isolates showed higher Cx activity than the moderately virulent ones in decayed fruit and in fruit tissue shake culture. β-Gal activities of the highly virulent isolates in pectin shake culture and in decayed fruit were greater than those of the two moderately virulent isolates although fruit also produced β-Gal. Protein analysis showed two fungal β-Gal isozymes in decayed fruit compared to those of healthy fruit. Correlation analysis indicated that the activities of PG, PNL, β-Gal and Cx in cultures and in decayed fruit positively correlated with fungal growth and fruit decay severity. The results of this study suggest that PG, PNL, β-Gal, and Cx appear to be virulence factors of D. bryoniae in cantaloupe decay with PG and β-Gal as the most predominant fruit decay enzymes. PMID:25364138
Coupling of Helmholtz resonators to improve acoustic liners for turbofan engines at low frequency
NASA Technical Reports Server (NTRS)
Dean, L. W.
1975-01-01
An analytical and test program was conducted to evaluate means for increasing the effectiveness of low frequency sound absorbing liners for aircraft turbine engines. Three schemes for coupling low frequency absorber elements were considered. These schemes were analytically modeled and their impedance was predicted over a frequency range of 50 to 1,000 Hz. An optimum and two off-optimum designs of the most promising, a parallel coupled scheme, were fabricated and tested in a flow duct facility. Impedance measurements were in good agreement with predicted values and validated the procedure used to transform modeled parameters to hardware designs. Measurements of attenuation for panels of coupled resonators were consistent with predictions based on measured impedance. All coupled resonator panels tested showed an increase in peak attenuation of about 50% and an increase in attenuation bandwidth of one one-third octave band over that measured for an uncoupled panel. These attenuation characteristics equate to about 35% greater reduction in source perceived noise level (PNL), relative to the uncoupled panel, or a reduction in treatment length of about 24% for constant PNL reduction. The increased effectiveness of the coupled resonator concept for attenuation of low frequency broad spectrum noise is demonstrated.
Process for vitrification of contaminated sodium oxide
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blair, H.T.; Mellinger, G.B.
1983-03-01
A glass composition was developed to accommodate 30 wt % sodium oxide and resist devitrification and leaching. An in-can melting process that is compatible with a comtaminated sodium calciner developed by Argonne National Laboratory was tested both on a laboratory and on an engineering scale and found to be viable. The Liquid Metal Fast Breeder Reactor experimental program continues to produce elemental sodium contaminated with radionuclides. This material is presently in temporary storage facilities because the current criterion will not permit alkali metals to be disposed of in shallow land burials. As a first step in treatment, Argonne National Laboratorymore » (ANL) has developed a calciner that will convert the sodium metal to an oxide. In work supported by the U.S. Department of Energy, Pacific Northwest Laboratory (PNL) is developing and demonstrating a process that is compatible with the calciner and facilities at ANL-West for incorporating sodium oxide into a glass. Glass, which normally contains sodium oxide, was chosen as the waste form because it is chemically durable and nondispersible. It is simple to produce, and the technology for incorporating nuclear wastes into glass is well developed.« less
Use of UUVs to Evaluate and Improve Model Performance Within a Tidally-Dominated Bay
2008-09-30
Sequim Bay Road Sequim , WA 98382 Phone: (360) 681-3616 Fax: (360) 681-3699 Email: lyle.hibler@pnl.gov Grant Number: N00014-07-1-1113 LONG-TERM...releasing rhodamine dye on the surface of Sequim Bay ( Sequim , Washington) from an anchored vessel in 2006. Concurrently collected data from the...advective transport from a point release in Sequim Bay , Washington. Tidal, wind-driven and density-driven circulation were accounted for in the model. The
Percutaneous nephrolithotomy in patients with a solitary kidney.
Süelözgen, Tufan; Budak, Salih; Celik, Orcun; Yalbuzdag, Okan; Mertoglu, Oguz; Isoglu, Selcuk; Yoldas, Mehmet; Ilbey, Yusuf Ozlem
2014-12-30
The results of percutaneous nephrolithotomy applied to 716 patients in our clinic between January 2008 and January 2014 were retrospectively evaluated. Age, gender, urinary calculi size (mm(2)), urinary calculi localization, ESWL history, operation duration (min), fluoroscopy duration (sec), access type, reason of solitary kidney, hemoglobin drawdown (g/dl) and operation success of the patients with a solitary kidney were recorded. The patients having no preoperative and postoperative non contrast abdominal tomography were excluded from the study. Fifteen of nineteen patients (79%) were men and 4 of them (21%) were women. The average age of the patients was 42.52 ± 16.72 (14-72). Ten patients had anatomical solitary kidney and nine patients had physiological solitary kidney. In fact counter kidney was non functional in 9 patients (47%) whereas there was agenesis in 2 (11%) and outcome of nephrectomy in 8 (42%) patients. In our study, presence of residual stone less than 4 mm at 1st month postoperative non contrast abdominal tomography was accepted as a successful result and accordingly our success rate was detected as 84%. Mean urinary calculi size was 405 ± 252.9 mm(2); urinary calculi localization was pelvic, lower pole, upper-middle pole, middle-lower pole and staghorn in 11 (58%), 4 (21%), 1 (5%), 1 (5%) and 1 (5%) patients, respectively; previous ESWL history was 16%; operation duration was 55.47-± 28.1 min and fluoroscopy duration 131.10 ± 87.6 sec; access type was subcostal in 79%, supracostal in 10.5% and multiple in 10.5%; hemoglobin drawdown was 1.75 ± 0.97 mg/dl. PNL can be effectively and safely administered for the treatment of solitary kidney. In the treatment of large urinary calculi in patients with a solitary kidney, PNL has some advantages such as short surgery duration, less complication, acceptable hemoglobin drawdown and high success rates. According to our study, PNL operation in patients with a solitary kidney is a good option for carefully and poisedly selected cases.
Development and characterization of a high-reliability, extended-lifetime H- ion source
NASA Astrophysics Data System (ADS)
Becerra, Gabriel; Barrows, Preston; Sherman, Joseph
2015-11-01
Phoenix Nuclear Labs (PNL) has designed and constructed a long-lifetime, negative hydrogen (H-) ion source, in partnership with Fermilab for an ion beam injector servicing future Intensity Frontier particle accelerators. The specifications for the low-energy beam transport (LEBT) section are 5-10 mA of continuous H- ion current at 30 keV with <0.2 π-mm-mrad emittance. Existing ion sources at Fermilab rely on plasma-facing electrodes, limiting their lifetime to a few hundred hours, while requiring relatively high gas loads on downstream components. PNL's design features an electron cyclotron resonance (ECR) microwave plasma driver which has been extensively developed in positive ion source systems, having demonstrated 1000+ hours of operation and >99% continuous uptime at PNL. Positive ions and hyperthermal neutrals drift toward a low-work-function surface, where a fraction is converted into H- hydrogen ions, which are subsequently extracted into a low-energy beam using electrostatic lenses. A magnetic filter preferentially removes high-energy electrons emitted by the source plasma, in order to mitigate H- ion destruction via electron-impact detachment. The design of the source subsystems and preliminary diagnostic results will be presented.
NASA Technical Reports Server (NTRS)
Kazin, S. B.; Paas, J. E.; Minzner, W. R.
1973-01-01
A scale model of the bypass flow region of a 1.5 pressure ratio, single stage, low tip speed fan was tested with a serrated rotor leading edge to determine its effects on noise generation. The serrated rotor was produced by cutting teeth into the leading edge of the nominal rotor blades. The effects of speed and exhaust nozzle area on the scale models noise characteristics were investigated with both the nominal rotor and serrated rotor. Acoustic results indicate the serrations reduced front quadrant PNL's at takeoff power. In particular, the 200 foot (61.0 m) sideline noise was reduced from 3 to 4 PNdb at 40 deg for nominal and large nozzle operation. However, the rear quadrant maximum sideline PNL's were increased 1.5 to 3 PNdb at approach thust and up to 2 PNdb at takeoff thust with these serrated rotor blades. The configuration with the serrated rotor produced the lowest maximum 200 foot (61.0 m) sideline PNL for any given thust when the large nozzle (116% of design area) was employed.
ElSheemy, Mohammed S; Shoukry, Ahmed I; Shouman, Ahmed M; ElShenoufy, Ahmed; Aboulela, Waseem; Daw, Kareem; Hussein, Ahmed A; Morsi, Hany A
2014-12-01
To describe and evaluate our protocol for management of children≤4years old with obstructive calcular anuria (OCA) and acute renal failure (ARF) to improve selection of initial urinary drainage (ID) method and to facilitate subsequent definitive stone management (DSM) as studies discussing this special group of patients are still few. Patients with a contraindication to any method of ID were excluded. Decision (percutaneous nephrostomy (PCN) or double J (JJ) stent) was based on degree of hydronephrosis and planned DSM. We used 4.8-5Fr JJ or 6-8Fr PCN under general anesthesia and fluoroscopic guidance. According to our protocol, JJ is inserted for hydronephrosis≤grade 1. When the hydronephrosis is >grade 1, patients with radiolucent stones were treated by JJ whatever the site of the stone. When the stones were radiopaque, PCN was reserved for stones in a solitary functioning kidney and bilateral ureteric stones prepared for subsequent bilateral ureterolithotomy (or stone prepared for ureterolithotomy in a solitary kidney). After normalization of renal functions, DSM was staged attacking only one side before discharge. Both sides were cleared at the same session in cases with bilateral ureterolithotomy. Renal or ureteric stones suitable for SWL in a solitary kidney were treated with percutaneous nephrolithotripsy (PNL) or ureteroscopy. This was followed also in patients with bilateral stones suitable for SWL by clearing one side using ureteroscopy or PNL before discharge. Open surgery (OS) was reserved for cases with failed ureteroscopy or PNL, for ureteric stones>2.5 cm in size or very large volume complex renal stones. Stone free rate (SFR) was evaluated by CT. Our protocol was evaluated as regard recovery of renal functions, complications, and number of interventions to clear stones. This study included 62 boys and 22 girls presented with anuria for 1-4 days. JJ and PCN were inserted in 105 and 30 ureterorenal units (URU), respectively. Creatinine returns normal within 72 h. JJ insertion formed a part of DSM in 78/159 (49%) URU (stones prepared for extracorporeal shockwave lithotripsy or oral chemolytic dissolution therapy). PCN was the ideal tract for subsequent PNL in 11/159 (6.9%) URU. Accordingly, ID participated by 55.97% in DSM. Both operative and imaging times were slightly longer with PCN than JJ. There was no statistically significant difference in the insertion success or mean period to return to normal chemistry. Complications of both methods were mild and without any significant difference. Endourologic procedures constituted the majority of our interventions. Open surgical and endoscopic interventions for clearance of stones (including ID, treatment conversion and 2ry procedures) were done once for 25 patients, twice for 43 patients while it was needed three times for 16 patients. Total number of interventions was 149 procedures. SFR was 94%. Our protocol ensures adequate ID with minimal complications when using our selection criteria in children≤4 years in age with OCA and ARF. It also minimizes number of subsequent procedures to clear stones. Complications and success in insertion and drainage were equivalent in PCN and JJ groups. Copyright © 2014 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Slurry spray distribution within a simulated laboratory scale spray dryer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bertone, P.C.
1979-12-20
It was found that the distribution of liquid striking the sides of a simulated room temperature spray dryer was not significantly altered by the choice of nozles, nor by a variation in nozzle operating conditions. Instead, it was found to be a function of the spray dryer's configuration. A cocurrent flow of air down the drying cylinder, not possible with PNL's closed top, favorably altered the spray distribution by both decreasing the amount of liquid striking the interior of the cylinder from 72 to 26% of the feed supplied, and by shifting the zone of maximum impact from 1.0 tomore » 1.7 feet from the nozzle. These findings led to the redesign of the laboratory scale spray dryer to be tested at the Savannah River Plant. The diameter of the drying chamber was increased from 5 to 8 inches, and a cocurrent flow of air was established with a closed recycle. Finally, this investigation suggested a drying scheme which offers all the advantages of spray drying without many of its limitations.« less
1975-08-01
defined for a noise event as: SELT - 10 log ALT i^dt L For purposes of aircraft noise evaluation, SELT is computed from tone-corrected A - levels sampled...In calculating values of PNLr PNLT, A - levels , EPNL, etc. T’ased on the Investigation summarized in Appendix C, we recommend that noise spectra be...handled In the following manner: a. Do not calculate or report PNL, PNLT, A - levels or other measures for spectra where less than 10 one- third
SHINE Tritium Nozzle Design: Activity 6, Task 1 Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Okhuysen, Brett S.; Pulliam, Elias Noel
In FY14, we studied the qualitative and quantitative behavior of a SHINE/PNL tritium nozzle under varying operating conditions. The result is an understanding of the nozzle’s performance in terms of important flow features that manifest themselves under different parametric profiles. In FY15, we will consider nozzle design with a focus on nozzle geometry and integration. From FY14 work, we will understand how the SHINE/PNL nozzle behaves under different operating scenarios. The first task for FY15 is to evaluate the FY14 model as a predictor of the actual flow. Considering different geometries is more time-intensive than parameter studies, therefore we recommendmore » considering any relevant flow features that were not included in the FY14 model. In the absence of experimental data, it is particularly important to consider any sources of heat in the domain or boundary conditions that may affect the flow and incorporate these into the simulation if they are significant. Additionally, any geometric features of the beamline segment should be added to the model such as the orifice plate. The FY14 model works with hydrogen. An improvement that can be made for FY15 is to develop CFD properties for tritium and incorporate those properties into the new models.« less
Determining the spatial altitude of the hydraulic fractures.
NASA Astrophysics Data System (ADS)
Khamiev, Marsel; Kosarev, Victor; Goncharova, Galina
2016-04-01
Mathematical modeling and numerical simulation are the most widely used approaches for the solving geological problems. They imply software tools which are based on Monte Carlo method. The results of this project presents shows the possibility of using PNL tool to determine fracturing location. The modeled media is a homogeneous rock (limestone) cut by a vertical borehole (d=216 mm) with metal casing 9 mm thick. The cement sheath is 35 mm thick. The borehole is filled with fresh water. The rock mass is cut by crack, filled with a mixture of doped (gadolinium oxide Gd2O3) proppant (75%) and water (25%). A pulse neutron logging (PNL) tool is used for quality control in hydraulic fracturing operations. It includes a fast neutron source (so-called "neutron generator") and a set of thermal (or epithermal) neutron-sensing devices, forming the so-called near (ND) and far (FD) detectors. To evaluate neutron properties various segments (sectors) of the rock mass, the detector must register only neutrons that come from this very formation. It's possible if detecting block includes some (6 for example) thermal neutron detectors arranged circumferentially inside the tool. As a result we get few independent well logs, each accords with define rock sector. Afterwards synthetic logs processing we can determine spatial position of the hydraulic fracture.
Hanford Site National Environmental Policy Act (NEPA) Characterization. Revision 5
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cushing, C.E.
1992-12-01
This fifth revision of the Hanford Site National Environmental Policy (NEPA) Characterization presents current environmental data regarding the Hanford Site and its immediate environs. This information is intended for use in preparing Site-related NEPA documentation. Information is presented on climate and meteorology, geology and hydrology, ecology, history and archaeology, socioeconomics, land use, and noise levels, prepared by Pacific Northwest Laboratory (PNL) staff. Models are described that are to be used in simulating realized or potential impacts from nuclear materials at the Hanford Site. Included are models of radionuclide transport in groundwater and atmospheric pathways, and of radiation dose to populationsmore » via all known pathways from known initial conditions. Federal and state regulations, DOE orders and permits, and environmental standards directly applicable for the NEPA documents at the Hanford Site, are provided.« less
Hanford Site National Environmental Policy Act (NEPA) Characterization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cushing, C.E.
1992-12-01
This fifth revision of the Hanford Site National Environmental Policy (NEPA) Characterization presents current environmental data regarding the Hanford Site and its immediate environs. This information is intended for use in preparing Site-related NEPA documentation. Information is presented on climate and meteorology, geology and hydrology, ecology, history and archaeology, socioeconomics, land use, and noise levels, prepared by Pacific Northwest Laboratory (PNL) staff. Models are described that are to be used in simulating realized or potential impacts from nuclear materials at the Hanford Site. Included are models of radionuclide transport in groundwater and atmospheric pathways, and of radiation dose to populationsmore » via all known pathways from known initial conditions. Federal and state regulations, DOE orders and permits, and environmental standards directly applicable for the NEPA documents at the Hanford Site, are provided.« less
ATES/heat pump simulations performed with ATESSS code
NASA Astrophysics Data System (ADS)
Vail, L. W.
1989-01-01
Modifications to the Aquifer Thermal Energy Storage System Simulator (ATESSS) allow simulation of aquifer thermal energy storage (ATES)/heat pump systems. The heat pump algorithm requires a coefficient of performance (COP) relationship of the form: COP = COP sub base + alpha (T sub ref minus T sub base). Initial applications of the modified ATES code to synthetic building load data for two sizes of buildings in two U.S. cities showed insignificant performance advantage of a series ATES heat pump system over a conventional groundwater heat pump system. The addition of algorithms for a cooling tower and solar array improved performance slightly. Small values of alpha in the COP relationship are the principal reason for the limited improvement in system performance. Future studies at Pacific Northwest Laboratory (PNL) are planned to investigate methods to increase system performance using alternative system configurations and operations scenarios.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brambley, M.R.; Weakley, S.A.
1990-09-01
This report presents the results of a preliminary assessment of opportunities for improvement at the US Marine Corps (USMC) Quantico, Virginia, Central Heating Plant (CHP). This study is part of a program intended to provide the CHP staff with a computerized Artificial Intelligence (AI) decision support system that will assist in a more efficient, reliable, and safe operation of their plant. As part of the effort to provide the AI decision support system, a team of six scientists and engineers from the Pacific Northwest Laboratory (PNL) visited the plant to characterize the conditions and environment of the CHP. This assessmentmore » resulted in a list of potential performance improvement opportunities at the CHP. In this report, 12 of these opportunities are discussed and qualitatively analyzed. 70 refs., 7 figs., 6 tabs.« less
Application of the TEMPEST computer code to canister-filling heat transfer problems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farnsworth, R.K.; Faletti, D.W.; Budden, M.J.
Pacific Northwest Laboratory (PNL) researchers used the TEMPEST computer code to simulate thermal cooldown behavior of nuclear waste glass after it was poured into steel canisters for long-term storage. The objective of this work was to determine the accuracy and applicability of the TEMPEST code when used to compute canister thermal histories. First, experimental data were obtained to provide the basis for comparing TEMPEST-generated predictions. Five canisters were instrumented with appropriately located radial and axial thermocouples. The canister were filled using the pilot-scale ceramic melter (PSCM) at PNL. Each canister was filled in either a continous or a batch fillingmore » mode. One of the canisters was also filled within a turntable simulant (a group of cylindrical shells with heat transfer resistances similar to those in an actual melter turntable). This was necessary to provide a basis for assessing the ability of the TEMPEST code to also model the transient cooling of canisters in a melter turntable. The continous-fill model, Version M, was found to predict temperatures with more accuracy. The turntable simulant experiment demonstrated that TEMPEST can adequately model the asymmetric temperature field caused by the turntable geometry. Further, TEMPEST can acceptably predict the canister cooling history within a turntable, despite code limitations in computing simultaneous radiation and convection heat transfer between shells, along with uncertainty in stainless-steel surface emissivities. Based on the successful performance of TEMPEST Version M, development was initiated to incorporate 1) full viscous glass convection, 2) a dynamically adaptive grid that automatically follows the glass/air interface throughout the transient, and 3) a full enclosure radiation model to allow radiation heat transfer to non-nearest neighbor cells. 5 refs., 47 figs., 17 tabs.« less
PRECP: the Department of Energy's program on the nonlinearity of acid precipitation processes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tanner, R.L.; Tichler, J.; Brown, R.
During the period of 1 April to 3 May 1985, staff from Argonne National Laboratory (ANL), Brookhaven National Laboratory (BNL), and Pacific Northwest Laboratory (PNL), participated in a multifaceted, coordinated set of field studies from an aircraft logistical base in Columbus, OH, and a surface precipitation and air chemistry network in the Philadelphia area. The general goals of these activities, conducted within the DOE-sponsored PRocessing of Emissions by Clouds and Precipitation (PRECP) program were to obtain information concerning scavenging ratios and the vertical distribution of cloud and precipitation chemistry for sulfur and nitrogen oxides and oxyacids, and for oxidant speciesmore » in the vicinity of precipitating and nonprecipitating clouds. Profiling of pollutant concentrations and phase distributions, and studies of scavenging processes were accomplished principally by airborne measurements of aerosol and gaseous species in pre-cloud and below-cloud air and of aqueous-phase species in clouds and precipitation, accompanied by documentation of meteorological and cloud physics parameters in the sampled regimes. Studies in the Midwest utilized only limited surface precipitation collection and chemical measurements, whereas a more extensive ground precipitation network was deployed in the Philadelphia area studies together with surface air chemistry measurements at a single nonurban site.« less
User's manual for the BNW-I optimization code for dry-cooled power plants. Volume I
DOE Office of Scientific and Technical Information (OSTI.GOV)
Braun, D.J.; Daniel, D.J.; De Mier, W.V.
1977-01-01
This User's Manual provides information on the use and operation of three versions of BNW-I, a computer code developed by Battelle, Pacific Northwest Laboratory (PNL) as a part of its activities under the ERDA Dry Cooling Tower Program. These three versions of BNW-I were used as reported elsewhere to obtain comparative incremental costs of electrical power production by two advanced concepts (one using plastic heat exchangers and one using ammonia as an intermediate heat transfer fluid) and a state-of-the-art system. The computer program offers a comprehensive method of evaluating the cost savings potential of dry-cooled heat rejection systems and componentsmore » for power plants. This method goes beyond simple ''figure-of-merit'' optimization of the cooling tower and includes such items as the cost of replacement capacity needed on an annual basis and the optimum split between plant scale-up and replacement capacity, as well as the purchase and operating costs of all major heat rejection components. Hence, the BNW-I code is a useful tool for determining potential cost savings of new heat transfer surfaces, new piping or other components as part of an optimized system for a dry-cooled power plant.« less
NASA Astrophysics Data System (ADS)
Wang, I. T.
A general method for determining the effective transport wind speed, overlineu, in the Gaussian plume equation is discussed. Physical arguments are given for using the generalized overlineu instead of the often adopted release-level wind speed with the plume diffusion equation. Simple analytical expressions for overlineu applicable to low-level point releases and a wide range of atmospheric conditions are developed. A non-linear plume kinematic equation is derived using these expressions. Crosswind-integrated SF 6 concentration data from the 1983 PNL tracer experiment are used to evaluate the proposed analytical procedures along with the usual approach of using the release-level wind speed. Results of the evaluation are briefly discussed.
Supine or prone position for mini-PNL procedure: does it matter.
Tokatlı, Zafer; Gokce, Mehmet Ilker; Süer, Evren; Sağlam, Remzi
2015-06-01
In this study it is aimed to compare the success and complication rates of mini-PNL procedure in supine and prone positions. In this retrospective study data of 180 patients treated with MPNL either in supine (n = 54) or prone (n = 126) positions between May 2009 and August 2014 was investigated. Success was defined as no visible stones >2 mm. Perioperative complications were classified using the modified Clavien system. Groups were compared with Chi square test or Student t test and for statistical significance p value of 0.05 was accepted. Mean age of the population was 42.5 ± 8.2 years and mean stone size was 23.9 ± 4.1 mm. The two groups were similar with regard to demographic characteristics and stone related characteristics except the ASA status. Success rates of the supine and prone groups were 85.1 and 87.3%, respectively (p = 0.701). No statistically significant differences in terms of complications were observed. Mean operative time was the only parameter different between the two groups (55 vs 82 min, p = 0.001). Supine position for PNL seems to be promising and the complication and success rates are shown to be similar to the prone position with MPNL technique. The only significant benefit of this technique is shorter operative time.
Thermal ionization of Cs Rydberg states
NASA Astrophysics Data System (ADS)
Glukhov, I. L.; Ovsiannikov, V. D.
2009-01-01
Rates Pnl of photoionization from Rydberg ns-, np-, nd-states of a valence electron in Cs, induced by black-body radiation, were calculated on the basis of the modified Fues model potential method. The numerical data were approximated with a three-term expression which reproduces in a simple analytical form the dependence of Pnl on the ambient temperature T and on the principal quantum number n. The comparison between approximate and exactly calculated values of the thermal ionization rate demonstrates the applicability of the proposed approximation for highly excited states with n from 20 to 100 in a wide temperature range of T from 100 to 10,000 K. We present coefficients of this approximation for the s-, p- and d-series of Rydberg states.
Hanford Environmental Dose Reconstruction Project. Monthly report, December 1991
DOE Office of Scientific and Technical Information (OSTI.GOV)
Finch, S.M.; McMakin, A.H.
1991-12-31
The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation doses that individuals and populations could have received from nuclear operations at Hanford since 1944. The project is being managed and conducted by the Pacific Northwest Laboratory (PNL) under the direction of an independent Technical Steering Panel (TSP). The TSP consists of experts in environmental pathways, epidemiology, surface-water transport, ground-water transport, statistics, demography, agriculture, meteorology, nuclear engineering, radiation dosimetry, and cultural anthropology. Included are appointed technical members representing the states of Oregon and Washington, a representative of Native American tribes, and an individual representing the public.more » The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed, from release to impact on human (dose estimates): Source Terms; Environmental Transport; Environmental Monitoring Data; Demographics, Agriculture, Food Habits and; Environmental Pathways and Dose Estimates.« less
Hanford Environmental Dose Reconstruction Project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Finch, S.M.; McMakin, A.H.
1991-01-01
The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation doses that individuals and populations could have received from nuclear operations at Hanford since 1944. The project is being managed and conducted by the Pacific Northwest Laboratory (PNL) under the direction of an independent Technical Steering Panel (TSP). The TSP consists of experts in environmental pathways, epidemiology, surface-water transport, ground-water transport, statistics, demography, agriculture, meteorology, nuclear engineering, radiation dosimetry, and cultural anthropology. Included are appointed technical members representing the states of Oregon and Washington, a representative of Native American tribes, and an individual representing the public.more » The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed, from release to impact on human (dose estimates): Source Terms; Environmental Transport; Environmental Monitoring Data; Demographics, Agriculture, Food Habits and; Environmental Pathways and Dose Estimates.« less
Glass-fiber-based neutron detectors for high- and low-flux environments
NASA Astrophysics Data System (ADS)
Bliss, Mary; Brodzinski, Ronald L.; Craig, Richard A.; Geelhood, Bruce D.; Knopf, Michael A.; Miley, Harry S.; Perkins, Richard W.; Reeder, Paul L.; Sunberg, Debra S.; Warner, Ray A.; Wogman, Ned A.
1995-09-01
Pacific Northwest Laboratory (PNL) has fabricated cerium-activated lithium silicate scintillating fibers via a hot-downdraw process. These fibers typically have a operational transmission length (e(superscript -1) length) of greater than 2 meters. This permits the fabrication of devices which were not possible to consider. Scintillating fibers permit conformable devices, large-area devices, and extremely small devices; in addition, as the thermal-neutron sensitive elements in a fast neutron detection system, scintillating fibers can be dispersed within moderator, improving neutron economy, over that possible with commercially available (superscript 3)He or BF(subscript 3) proportional counters. These fibers can be used for national-security applications, in medical applications, in the nuclear-power industry, and for personnel protection at experimental facilities. Data are presented for devices based on single fibers and devices made up of ribbons containing many fibers under high-and low-flux conditions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kennedy, R A; Mahaffey, J A; Carr, F Jr
This bibliography has been prepared by Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE) Office of Health and Environmental Research to provide bibliographic information in a usable format for research studies relating to the Chernobyl nuclear accident that occurred in the Ukrainian Republic, USSR in 1986. This report is a product of the Chernobyl Database Management project. The purpose of this project is to produce and maintain an information system that is the official United States repository for information related to the accident. Two related products prepared for this project are the Chernobyl Bibliographic Search System (ChernoLit{trademark})more » and the Chernobyl Radiological Measurements Information System (ChernoDat). This report supersedes the original release of Chernobyl Bibliography (Carr and Mahaffey, 1989). The original report included about 2200 references. Over 4500 references and an index of authors and editors are included in this report.« less
Results from a workshop on research needs for modeling aquifer thermal energy storage systems
NASA Astrophysics Data System (ADS)
Drost, M. K.
1990-08-01
A workshop an aquifer thermal energy storage (ATES) system modeling was conducted by Pacific Northwest Laboratory (PNL). The goal of the workshop was to develop a list of high priority research activities that would facilitate the commercial success of ATES. During the workshop, participants reviewed currently available modeling tools for ATES systems and produced a list of significant issues related to modeling ATES systems. Participants assigned a priority to each issue on the list by voting and developed a list of research needs for each of four high-priority research areas; the need for a feasibility study model, the need for engineering design models, the need for aquifer characterization, and the need for an economic model. The workshop participants concluded that ATES commercialization can be accelerated by aggressive development of ATES modeling tools and made specific recommendations for that development.
Simulation of irradiation creep
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reiley, T.C.; Jung, P.
1977-01-01
The results to date in the area of radiation enhanced deformation using beams of light ions to simulate fast neutron displacement damage are reviewed. A comparison is made between these results and those of in-reactor experiments. Particular attention is given to the displacement rate calculations for light ions and the electronic energy losses and their effect on the displacement cross section. Differences in the displacement processes for light ions and neutrons which may effect the irradiation creep process are discussed. The experimental constraints and potential problem areas associated with these experiments are compared to the advantages of simulation. Support experimentsmore » on the effect of thickness on thermal creep are presented. A brief description of the experiments in progress is presented for the following laboratories: HEDL, NRL, ORNL, PNL, U. of Lowell/MIT in the United States, AERE Harwell in the United Kingdom, CEN Saclay in France, GRK Karlsruhe and KFA Julich in West Germany.« less
Molybdenum-base cermet fuel development
NASA Astrophysics Data System (ADS)
Pilger, James P.; Gurwell, William E.; Moss, Ronald W.; White, George D.; Seifert, David A.
Development of a multimegawatt (MMW) space nuclear power system requires identification and resolution of several technical feasibility issues before selecting one or more promising system concepts. Demonstration of reactor fuel fabrication technology is required for cermet-fueled reactor concepts. The MMW reactor fuel development activity at Pacific Northwest Laboratory (PNL) is focused on producing a molybdenum-matrix uranium-nitride (UN) fueled cermte. This cermet is to have a high matrix density (greater than or equal to 95 percent) for high strength and high thermal conductance coupled with a high particle (UN) porosity (approximately 25 percent) for retention of released fission gas at high burnup. Fabrication process development involves the use of porous TiN microspheres as surrogate fuel material until porous Un microspheres become available. Process development was conducted in the areas of microsphere synthesis, particle sealing/coating, and high-energy-rate forming (HERF) and the vacuum hot press consolidation techniques. This paper summarizes the status of these activities.
Overview of technology modeling in the Remedial Action Assessment System (RAAS)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, C.D.; Bagaasen, L.M.; Chan, T.C.
1994-08-01
There are numerous hazardous waste sites under the jurisdiction of the US Department of Energy (DOE). To assist the cleanup of these sites in a more consistent, timely, and cost-effective manner, the Remedial Action Assessment System (RAAS) is being developed by the Pacific Northwest Laboratory (PNL). RAAS is a software tool designed to automate the initial technology selection within the remedial investigation/feasibility study (RI/FS) process. The software does several things for the user: (1) provides information about available remedial technologies, (2) sorts possible technologies to recommend a list of technologies applicable to a given site, (3) points out technical issuesmore » that may prevent the implementation of a technology, and (4) provides an estimate of the effectiveness of a given technology at a particular site. Information from RAAS can be used to compare remediation options and guide selection of technologies for further study.« less
National briefing summaries: Nuclear fuel cycle and waste management
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schneider, K.J.; Bradley, D.J.; Fletcher, J.F.
Since 1976, the International Program Support Office (IPSO) at the Pacific Northwest Laboratory (PNL) has collected and compiled publicly available information concerning foreign and international radioactive waste management programs. This National Briefing Summaries is a printout of an electronic database that has been compiled and is maintained by the IPSO staff. The database contains current information concerning the radioactive waste management programs (with supporting information on nuclear power and the nuclear fuel cycle) of most of the nations (except eastern European countries) that now have or are contemplating nuclear power, and of the multinational agencies that are active in radioactivemore » waste management. Information in this document is included for three additional countries (China, Mexico, and USSR) compared to the prior issue. The database and this document were developed in response to needs of the US Department of Energy.« less
Waste isolation safety assessment program. Task 4. Third contractor information meeting
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1980-06-01
The Contractor Information Meeting (October 14 to 17, 1979) was part of the FY-1979 effort of Task 4 of the Waste Isolation Safety Assessment Program (WISAP): Sorption/Desorption Analysis. The objectives of this task are to: evaluate sorption/desorption measurement methods and develop a standardized measurement procedure; produce a generic data bank of nuclide-geologic interactions using a wide variety of geologic media and groundwaters; perform statistical analysis and synthesis of these data; perform validation studies to compare short-term laboratory studies to long-term in situ behavior; develop a fundamental understanding of sorption/desorption processes; produce x-ray and gamma-emitting isotopes suitable for the study ofmore » actinides at tracer concentrations; disseminate resulting information to the international technical community; and provide input data support for repository safety assessment. Conference participants included those subcontracted to WISAP Task 4, representatives and independent subcontractors to the Office of Nuclear Waste Isolation, representatives from other waste disposal programs, and experts in the area of waste/geologic media interaction. Since the meeting, WISAP has been divided into two programs: Assessment of Effectiveness of Geologic Isolation Systems (AEGIS) (modeling efforts) and Waste/Rock Interactions Technology (WRIT) (experimental work). The WRIT program encompasses the work conducted under Task 4. This report contains the information presented at the Task 4, Third Contractor Information Meeting. Technical Reports from the subcontractors, as well as Pacific Northwest Laboratory (PNL), are provided along with transcripts of the question-and-answer sessions. The agenda and abstracts of the presentations are also included. Appendix A is a list of the participants. Appendix B gives an overview of the WRIT program and details the WRIT work breakdown structure for 1980.« less
Complete Sequence of a 184-Kilobase Catabolic Plasmid from Sphingomonas aromaticivorans F199†
Romine, Margaret F.; Stillwell, Lisa C.; Wong, Kwong-Kwok; Thurston, Sarah J.; Sisk, Ellen C.; Sensen, Christoph; Gaasterland, Terry; Fredrickson, Jim K.; Saffer, Jeffrey D.
1999-01-01
The complete 184,457-bp sequence of the aromatic catabolic plasmid, pNL1, from Sphingomonas aromaticivorans F199 has been determined. A total of 186 open reading frames (ORFs) are predicted to encode proteins, of which 79 are likely directly associated with catabolism or transport of aromatic compounds. Genes that encode enzymes associated with the degradation of biphenyl, naphthalene, m-xylene, and p-cresol are predicted to be distributed among 15 gene clusters. The unusual coclustering of genes associated with different pathways appears to have evolved in response to similarities in biochemical mechanisms required for the degradation of intermediates in different pathways. A putative efflux pump and several hypothetical membrane-associated proteins were identified and predicted to be involved in the transport of aromatic compounds and/or intermediates in catabolism across the cell wall. Several genes associated with integration and recombination, including two group II intron-associated maturases, were identified in the replication region, suggesting that pNL1 is able to undergo integration and excision events with the chromosome and/or other portions of the plasmid. Conjugative transfer of pNL1 to another Sphingomonas sp. was demonstrated, and genes associated with this function were found in two large clusters. Approximately one-third of the ORFs (59 of them) have no obvious homology to known genes. PMID:10049392
Effect of at-the-source noise reduction on performance and weights of a tilt-rotor aircraft
NASA Technical Reports Server (NTRS)
Gibs, J.; Stepniewski, W. Z.; Spencer, R.
1975-01-01
Reduction of far-field acoustic signature through modification of basic design parameters (tip speed, number of blades, disc loading and rotor blade area) was examined, using a tilt-rotor flight research aircraft as a baseline configuration. Of those design parameters, tip speed appeared as the most important. Next, preliminary design of two aircraft was performed, postulating the following reduction of noise level from that of the baseline machine, at 500 feet from the spot of OGE hover. In one aircraft, the PNL was lowered by 10 PNdB and in the other, OASPL decreased by 10 dB. The resulting weight and performance penalties were examined. Then, PNL and EPNL aspects of terminal operation were compared for the baseline and quieter aircraft.
The HVT technique and the 'uncertainty' relation for central potentials
NASA Astrophysics Data System (ADS)
Grypeos, M. E.; Koutroulos, C. G.; Oyewumi, K. J.; Petridou, Th
2004-08-01
The quantum mechanical hypervirial theorems (HVT) technique is used to treat the so-called 'uncertainty' relation for quite a general class of central potential wells, including the (reduced) Poeschl-Teller and the Gaussian one. It is shown that this technique is quite suitable in deriving an approximate analytic expression in the form of a truncated power series expansion for the dimensionless product Pnl equiv langr2rangnllangp2rangnl/planck2, for every (deeply) bound state of a particle moving non-relativistically in the well, provided that a (dimensionless) parameter s is sufficiently small. Attention is also paid to a number of cases, among the limited existing ones, in which exact analytic or semi-analytic expressions for Pnl can be derived. Finally, numerical results are given and discussed.
Staff exchange with Chemical Waste Management. Final project report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harrer, B.J.; Barak, D.W.
1993-12-01
Original objective was transfer of PNL technology and expertise in computational chemistry and waste flow/treatment modeling to CWM. Identification and characterization of a broader portfolio of PNL`s environmental remediation technologies with high potential for rapid application became the focus of the exchange, which included E-mail exchanges. Of the 14 technologies discussed, the following were identified as being of high interest to CWM: six phase soil heating (in-situ heating), high energy electrical corona, RAAS/ReOpt{trademark} (remedial, expert system), TEES{trademark} (catalytic production of methane from biological wastes), PST (process for treating petroleum sludge). CWM`s reorganization and downsizing reduced the potential benefits to industry,more » but a proposal for transfer and application of PST to Wheelabrator was made.« less
Locating and Modeling Regional Earthquakes with Broadband Waveform Data
NASA Astrophysics Data System (ADS)
Tan, Y.; Zhu, L.; Helmberger, D.
2003-12-01
Retrieving source parameters of small earthquakes (Mw < 4.5), including mechanism, depth, location and origin time, relies on local and regional seismic data. Although source characterization for such small events achieves a satisfactory stage in some places with a dense seismic network, such as TriNet, Southern California, a worthy revisit to the historical events in these places or an effective, real-time investigation of small events in many other places, where normally only a few local waveforms plus some short-period recordings are available, is still a problem. To address this issue, we introduce a new type of approach that estimates location, depth, origin time and fault parameters based on 3-component waveform matching in terms of separated Pnl, Rayleigh and Love waves. We show that most local waveforms can be well modeled by a regionalized 1-D model plus different timing corrections for Pnl, Rayleigh and Love waves at relatively long periods, i.e., 4-100 sec for Pnl, and 8-100 sec for surface waves, except for few anomalous paths involving greater structural complexity, meanwhile, these timing corrections reveal similar azimuthal patterns for well-located cluster events, despite their different focal mechanisms. Thus, we can calibrate the paths separately for Pnl, Rayleigh and Love waves with the timing corrections from well-determined events widely recorded by a dense modern seismic network or a temporary PASSCAL experiment. In return, we can locate events and extract their fault parameters by waveform matching for available waveform data, which could be as less as from two stations, assuming timing corrections from the calibration. The accuracy of the obtained source parameters is subject to the error carried by the events used for the calibration. The detailed method requires a Green_s function library constructed from a regionalized 1-D model together with necessary calibration information, and adopts a grid search strategy for both hypercenter and focal mechanism. We show that the whole process can be easily automated and routinely provide reliable source parameter estimates with a couple of broadband stations. Two applications in the Tibet Plateau and Southern California will be presented along with comparisons of results against other methods.
NASA Astrophysics Data System (ADS)
Walker, A. P.; Zaehle, S.; Medlyn, B. E.; De Kauwe, M. G.; Asao, S.; Hickler, T.; Lomas, M. R.; Pak, B. C.; Parton, W. J.; Quegan, S.; Ricciuto, D. M.; Wang, Y.; Warlind, D.; Norby, R. J.
2013-12-01
Predicting forest carbon (C) sequestration requires understanding the processes leading to rates of biomass C accrual (net primary productivity; NPP) and loss (turnover). In temperate forest ecosystems, experiments and models have shown that feedback via progressive nitrogen limitation (PNL) is a key driver of NPP responses to elevated CO[2]. In this analysis we show that while still important, PNL may not be as severe a constraint on NPP as indicated by some studies and that the response of turnover to elevated CO[2] could be as important, especially in the near to medium term. Seven terrestrial ecosystem and biosphere models that couple C and N cycles with varying assumptions and complexity were used to simulate responses over 300 years to a step change in CO[2] to 550 ppmv. Simulations were run for the evergreen needleleaf Duke forest and the deciduous broadleaf Oak Ridge forest FACE experiments. Whether or not a model simulated PNL under elevated CO[2] depended on model structure and the timescale of observation. Avoiding PNL depended on mechanisms that reduced ecosystem N losses. The two key assumptions that reduced N losses were whether plant N uptake was based on plant N demand and whether ecosystem N losses (volatisation and leaching) were dependent on the concentration of N in the soil solution. Assumptions on allocation and turnover resulted in very different responses of turnover to elevated CO[2], which had profound implications for C sequestration. For example, at equilibrium CABLE2.0 predicted an increase in vegetation C sequestration despite decreased NPP, while O-CN predicted much less vegetation C sequestration than would be expected from predicted NPP increases alone. Generally elevated CO[2] favoured a shift in C partitioning towards longer lived wood biomass, which increased vegetation turnover and enhanced C sequestration. Enhanced wood partitioning was overlaid by increases or decreases in self-thinning depended on whether self-thinning was simply a function of forest structure, or structure and NPP. Self-thinning assumptions altered equilibrium C sequestration and were extremely important for the immediate transient response and near-term prediction of C sequestration.
Line Parameters Of CH3CN From 305 To 415 cm-1
NASA Astrophysics Data System (ADS)
Brown, Linda R.; Kamadjeu, D. A.; Kleiner, I.; Orphal, J.; Sams, R. L.
2006-12-01
Mapping important compounds, such as hydrocarbons and nitriles, is needed in order to understand the photochemical cycle of Titan and how it couples with the dynamics to produce organic aerosols. For this, the CIRS spectrometer (Composite Infrared Spectrometer) on board Cassini is currently recording rotation and vibration-rotation spectra of Titan between 10 and 1400 cm-1. To support analysis of these data, high resolution laboratory spectra of CH3CN have been recorded using Fourier transform spectrometers at PNL and LISA. This paper presents a prediction of line positions and intensities of CH3 CN for the ν&8 fundamental and the 2ν8 -ν8 hot band (located near 360 cm&-1). Analyses of the two fundamentals near 10 microns are in progress. Part of the research described in this paper was performed at the Jet Propulsion Laboratory, California Institute of Technology, under contract with The National Aeronautics and Space Administration. I.K, J. O and A. D. also want to thank the Programme National de Planétologie for funding part of this research. This research was supported, in part, by the United States Department of Energy, Office of Basic Energy Sciences, Chemical Sciences Division and the experimental part was performed at the W. R, Wiley Environmental Molecular Science Laboratory, a national scientific user facility sponsored by the Department of Energy's Office of Biological and Environmental Research located at the Pacific Northwest National Laboratory. Pacific Northwest National Laboratory is operated for the United States Department of Energy by Battelle under contract DE-AC06-76RLO 1830. We wish to thank Drs R. Antilla and S. Alanko for kindly making available supplemental data in electronic and paper forms. #
Error analysis and system optimization of non-null aspheric testing system
NASA Astrophysics Data System (ADS)
Luo, Yongjie; Yang, Yongying; Liu, Dong; Tian, Chao; Zhuo, Yongmo
2010-10-01
A non-null aspheric testing system, which employs partial null lens (PNL for short) and reverse iterative optimization reconstruction (ROR for short) technique, is proposed in this paper. Based on system modeling in ray tracing software, the parameter of each optical element is optimized and this makes system modeling more precise. Systematic error of non-null aspheric testing system is analyzed and can be categorized into two types, the error due to surface parameters of PNL in the system modeling and the rest from non-null interferometer by the approach of error storage subtraction. Experimental results show that, after systematic error is removed from testing result of non-null aspheric testing system, the aspheric surface is precisely reconstructed by ROR technique and the consideration of systematic error greatly increase the test accuracy of non-null aspheric testing system.
Penbegul, Necmettin; Utangac, Mehmet Mazhar; Daggulli, Mansur; Dede, Onur; Bozkurt, Yasar; Bodakci, Mehmet Nuri; Atar, Murat
2016-06-01
Micropercutaneous nephrolithotomy (microperc) is a recently introduced percutaneous nephrolithotomy (PNL) technique that has the smallest tract size. The absence of an amplatz sheath during the microperc technique is a fundamental difference that distinguishes it from all other types of PNL (standard, mini, ultramini). Increasing of the intrarenal pelvic pressure (IPP) was demonstrated by the authors in adult patients but this problem may be even more serious in pediatric patients. Previously, the authors defined the use of a 14 gauge angiocath needle and sheath (microsheath) during microperc surgery for pediatric patient to reduce the IPP. In this novel technique, a second angiocath is used to access the renal collecting system to drain fluid during surgery. This technique is more effective in reducing IPP during microperc, especially in pediatric patients. Copyright © 2016 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bird, S.P.
1978-03-01
Biofouling and corrosion of heat exchanger surfaces in Ocean Thermal Energy Conversion (OTEC) systems may be controlling factors in the potential success of the OTEC concept. Very little is known about the nature and behavior of marine fouling films at sites potentially suitable for OTEC power plants. To facilitate the acquisition of needed data, a biofouling measurement device developed by Professor J. G. Fetkovich and his associates at Carnegie-Mellon University (CMU) has been mass produced for use by several organizations in experiments at a variety of ocean sites. The CMU device is designed to detect small changes in thermal resistancemore » associated with the formation of marine microfouling films. An account of the work performed at the Pacific Northwest Laboratory (PNL) to develop a computerized uncertainty analysis for estimating experimental uncertainties of results obtained with the CMU biofouling measurement device and data reduction scheme is presented. The analysis program was written as a subroutine to the CMU data reduction code and provides an alternative to the CMU procedure for estimating experimental errors. The PNL code was used to analyze sample data sets taken at Keahole Point, Hawaii; St. Croix, the Virgin Islands; and at a site in the Gulf of Mexico. The uncertainties of the experimental results were found to vary considerably with the conditions under which the data were taken. For example, uncertainties of fouling factors (where fouling factor is defined as the thermal resistance of the biofouling layer) estimated from data taken on a submerged buoy at Keahole Point, Hawaii were found to be consistently within 0.00006 hr-ft/sup 2/-/sup 0/F/Btu, while corresponding values for data taken on a tugboat in the Gulf of Mexico ranged up to 0.0010 hr-ft/sup 2/-/sup 0/F/Btu. Reasons for these differences are discussed.« less
The pre-audit assessment: A homework assignment for auditors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marschman, S.C.
1993-02-01
The role of the quality assurance audit is evolving from compliance verification to a much broader assessment of programmatic and management performance. In the past, audits were poorly understood and caused fear and trepidation. Auditees turned an audit into a cat-and-mouse game using coverup strategies and decoy discrepancies. These games were meant to ``give the auditors what they want, namely a few findings that could later be easily corrected. At Pacific Northwest Laboratory (PNL), I observed auditing become a spectator sport. Matching a compliance-oriented auditor against a crafty group of scientists provided hours of entertainment. As a program manager, itmore » was clear these games were neither productive useful nor cost effective. Fortunately, over the past few years several concepts embraced by ``total quality management` have begun to emerge at PNL. These concepts are being adopted by most successful organizations, and based on these concepts new tools and ideas are emerging to help organizations improve productivity and quality. Successful organizations have been and are continuing to develop management strategies that rely on participative approaches to their operations. These approaches encourage the empowerment of organization staff at all levels, with the goal of instilling ownership of quality in every staff member. As management philosophies are changing, so are the responsibilities and expectations of managers. Managers everywhere are experimenting with new tools to help them improve their operations and competitiveness. As the quality audit evolves, managers and other customers of the audit process have developed expectations for the auditing process that never existed in years past. These expectations have added complexity to the audit process. It is no longer adequate to prepare a checklist, perform the audit, and document the results. When viewed as a tool for verifying performance, a quality audit becomes more than a compliance checklist.« less
The pre-audit assessment: A homework assignment for auditors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marschman, S.C.
1993-02-01
The role of the quality assurance audit is evolving from compliance verification to a much broader assessment of programmatic and management performance. In the past, audits were poorly understood and caused fear and trepidation. Auditees turned an audit into a cat-and-mouse game using coverup strategies and decoy discrepancies. These games were meant to give the auditors what they want, namely a few findings that could later be easily corrected. At Pacific Northwest Laboratory (PNL), I observed auditing become a spectator sport. Matching a compliance-oriented auditor against a crafty group of scientists provided hours of entertainment. As a program manager, itmore » was clear these games were neither productive useful nor cost effective. Fortunately, over the past few years several concepts embraced by total quality management' have begun to emerge at PNL. These concepts are being adopted by most successful organizations, and based on these concepts new tools and ideas are emerging to help organizations improve productivity and quality. Successful organizations have been and are continuing to develop management strategies that rely on participative approaches to their operations. These approaches encourage the empowerment of organization staff at all levels, with the goal of instilling ownership of quality in every staff member. As management philosophies are changing, so are the responsibilities and expectations of managers. Managers everywhere are experimenting with new tools to help them improve their operations and competitiveness. As the quality audit evolves, managers and other customers of the audit process have developed expectations for the auditing process that never existed in years past. These expectations have added complexity to the audit process. It is no longer adequate to prepare a checklist, perform the audit, and document the results. When viewed as a tool for verifying performance, a quality audit becomes more than a compliance checklist.« less
Basic principles and recent observations of rotationally sampled wind
NASA Technical Reports Server (NTRS)
Connell, James R.
1995-01-01
The concept of rotationally sampled wind speed is described. The unusual wind characteristics that result from rotationally sampling the wind are shown first for early measurements made using an 8-point ring of anemometers on a vertical plane array of meteorological towers. Quantitative characterization of the rotationally sampled wind is made in terms of the power spectral density function of the wind speed. Verification of the importance of the new concept is demonstrated with spectral analyses of the response of the MOD-OA blade flapwise root bending moment and the corresponding rotational analysis of the wind measured immediately upwind of the MOD-OA using a 12-point ring of anemometers on a 7-tower vertical plane array. The Pacific Northwest Laboratory (PNL) theory of the rotationally sampled wind speed power spectral density function is tested successfully against the wind spectrum measured at the MOD-OA vertical plane array. A single-tower empirical model of the rotationally sampled wind speed is also successfully tested against the measurements from the full vertical plane array. Rotational measurements of the wind velocity with hotfilm anemometers attached to rotating blades are shown to be accurate and practical for research on winds at the blades of wind turbines. Some measurements at the rotor blade of a MOD-2 turbine using the hotfilm technique in a pilot research program are shown. They are compared and contrasted to the expectations based upon application of the PNL theory of rotationally sampled wind to the MOD-2 size and rotation rate but without teeter, blade bending, or rotor induction accounted for. Finally, the importance of temperature layering and of wind modifications due to flow over complex terrain is demonstrated by the use of hotfilm anemometer data, and meteorological tower and acoustic doppler sounder data from the MOD-2 site at Goodnoe Hills, Washington.
Why should we pay more for layout designers?
NASA Astrophysics Data System (ADS)
Khan, Samee U.
2003-12-01
In this paper, we discuss the Passive Optical Network (PON) deployment on an arbitrary grid with guarenteed p-1 equipment failure. We show that this problem in general is NP-hard. We propose an algorithm, which guarantees a solution of 4-approximation to the optimal deployment, and further argue that this is the best lower bound achievable in our case.A basic architecture of PON is shown in figure 1.The main component of PON is an optical splitter device. Depending on which direction the light is travelling, it splits the incoming light and distributes it to multiple fibers towards Optical Network Termination (ONT), or combines it into one towards Optical Line Terminal (OLT). The PON technology uses a double-star architecture. The first star topology centers at the OLT, and the second at the optical splitter. PROBLEM DESCRIPTION: We can formulate the problem of optimal p-1 fault-tolerent PON Network Layout (PNL)as a graph theoretical problem. Consider a graph G(V,E), such that V represent the physical locations of the subscriber's, CO, and another location acquired by the CO to expand its network, and E represent the communication lines between two Vi's. If there is no direct communication line c(i,j) between Vi and Vj, we consider the shortest path between them measured in terms of simple distance or cost constraints. Without the loss of generality we assume that c(i,j)=c(j,i). For simplicity we do not further sub-divide V into the obvious categories that represent the locations of OLT, ONT, CO, optical splitters and the subscribers. We can now formulate the PNL problem as follows: "Given an undirected graph G, find the locations of ONTs and splitters such that the cost of the equipment is minimized and for QoS the maximum distance from an ONT to the pth splitter and from a splitter to the pth OLT is minimized". We assume that the OLT is residing inside the CO. The problem definition does not consider the optimization of ONT to the customer premises. This is due to the fact that the distance from ONT to the premises is negligibly small, and fault tolerance for a failed ONT can be answered by replacing the connection from a nearby ONT. We will treat ONT and ONU as more or less the same entity. GENERALIZED PNL IS NP-Hard: Essentially our problem definition consists of two major optimization steps, i.e. ONT to splitters and splitters to the OLT. Showing the hardness of the problem over one optimization step would be sufficient to show that the over all the problem is hard. If we consider the optimization of the first phase of the problem, i.e. minimize the maximum distance of ONTs to the splitters and reduce the cost of the equipment, this can be solved by associating cost to vertices V (equipment cost) and edges E (fiber cost). Thus the problem reduces to finding the smallest number of minimum cost edges from a splitter to an ONT, such that the chosen set of edges identify vertices that connect in a min-max fashion. Lemma 1 Let U be maximal k-independent set such that |U|>=k, then U is a k-dominating set in G^2. Proof (follows form def 1&2) Lemma 2 Let V be a k-dominating set in G, then |U|<=|V| holds for any k-independent set U in G^2. Proof For the two non-trivial cases of U subset V, a) U is not contained in V. Pick a node u at random such that u belongs U-V. Thus a set of nodes S can be defined such that the neighborhood of u N(u) is not contained in V, i.e. S=N(u) intersection V. Let L define the set of nodes that are adjacent to S, then any node v in SUL is contained in G^2 (definition 2) and is adjacent to at most k vertices in SUL. b) U is contained in V. If U is contained in V, then we can define a graph G containing vertices V-(SUL). Thus the lemma would hold, if V'=V-(SUL)=V-S, where V' is a k-dominating set in G. Pick a random node v in G not contained in V, then v belongs to V-V', and v has atleast k neighbors in G not present in V'. Since we assumed that V' is a k-dominating set in G, no neighbor belongs to G (by definition of G). Thus N(v) intersection V' is a subset of V'. Theorem 1 Assuming P!=NP, for any arbitrary fixed a<=p, there does not exist any polynomial time algorithm for PNL. Proof Suppose we have an algorithm A, which gives a solution for the PNL problem, then a solution for dominating set can be obtained. We will now give a polynomial time reduction from PNL to the dominating set problem. Let |V| be the pairwise neighborhood graph such that by picking any vertex v in V, N(v) intersection V is null. Thus the graph to find PNL (figure 2) can be computed by picking vertices as follows:(u,v)= 1 if u,v belongs V(u,v)= 1 if u belongs V and n belongs N(v) (u,v)= f(|V|)+ epsilon otherwise The choice of epsilon, exhibits the epsilon approximation factor in the final layout. If G has the dominating set of size d, then the solution for PNL has a set J such that dUN(v) is a set of nodes with cardinality d+(a-1), where a<=p. For a=1, the problem reduces to minimum k-center problem, so we will consider a>=2. Pick any node v in N(v). It is clear that v has only one neighbor in V', which is at a distance of 1 (triangle inequality). If it is not equal to 1, then it must be covered by a neibours within a distance of 1. Let Z=P intersection V such that Z is subset of V and contains d nodes such that d=|P|-(a-1)|V|, then any arbitrary node v belongs to V-Z must have atleast a nodes in P with a adistance of 1, but by definition and previous argument, only a-1 nodes can form the neighborhood. Thus, Z is a dominating set of size d, but by lemma 2, G cannot contain a dominating set of size d. OUR APPROACH: We assume that the edges of the graph G have the triangle inequality property. Let Si represent the set of weighted vertices w(v) such that once picked, they form a clique in graph G. PNL Algorithm Input: G Output: G' (Final PNL) 1. Construct G1^2,G2^2,....,Gm^2 2. Compute I, (Mi) in each Gi^2 3. Find the smallest index i, such that |Mi|<=k, say Mj 4. Input Mj for step 5. 5. Construct G1j^2,G2j^2,....,Gmj^2 6. Compute I, (Mij) in each Gij^2 7. Compute Si=si(u)|u belongs to Mij 8. Find the minimum index i such that w(Si)<= w(D) 9. Return Sj 10. Compute G'=min Mij belongs V [max si sum{i=0}^{|Sj|] 11. Return G' Theorem 2 The PNL algorithm is complete and will identify a solution, if there exists one. Proof (Trivial and not included due to space) Theorem 3 The PNL algorithm has a lower bound of 4-approximation to the optimal algorithm. Proof (Not included due to space, but the basic argument, is due to the fact that picking a node v with 2-epsilon in G^2, would required the neighbors to be picked in G^4, thus the PNL is no better than 4-epsilon, where epsilon >0) Experiments We made some initial experiments, which are showing promissing results with savings in fiber, equipment cost, due to space, and inital phase of the experiments, we are not including the results here. P.S. My appologies for exceeding the text limit. There is much more detail to the formal proof, I hope the idea is still conveyed. There are also 2 figures which will be faxed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wright, J.; Conca, J.
1996-10-01
The objective of this Cooperative Research and Development Agreement (CRADA) was to develop and commercialize a technology conceived by scientists at Pacific Northwest National Laboratory (PNNL) and manufactured by Beckman Instruments, Inc. (Beckman), and to apply this technology to the characterization of and soils. The technology is the Unsaturated Flow Apparatus (UFA). The UFA provides a highly efficient method of direct, rapid measurement of hydraulic conductivity and other flow properties according to Darcy-Buckingham principles because the operator controls both the fluid driving force, using an ultracentrifuge, and the flow into the sample while it is spinning, with a rotating sealmore » assembly. The concept of using centrifugation to significantly decrease the time needed, from years or months to days, for study of subsurface transport, particularly under unsaturated conditions, was conceived by James Conca, Ph.D., and Judith Wright, Ph.D., in 1986. The prototype UFA was developed in 1988 because there was a need to rapidly and accurately determine transport parameters in soils, sediments, and rocks for the Grout Waste Disposal Program. Transport parameters are critical to modeling outcomes for site-specific solutions to environmental remediation and waste disposal problems.« less
A comparison of two independent measurements and analysis of jet aircraft flyover noise
NASA Technical Reports Server (NTRS)
Hosier, R. N.
1977-01-01
Flyover noise measurements were made simultaneously by two groups. The measurements were made close to one another for the same flyover conditions and with similar measurement procedures, but with different acoustic equipment and personnel. Each group also independently processed the data in accordance with FAR 36 procedures, indluding corrections to reference meteorological, performance, and flight-path conditions. Measured and corrected data, from 24 controlled flyovers processed by both groups, are compared and the differences in the results obtained by the two groups are discussed. It is observed that the average value of the difference between the groups' measured acoustic descriptors (PNL, PNLTM, and EPNL) was less than or = 0.8 db; the average difference for the corrected descriptors (PNL, PNLTM, and EPNL) was less than or = 1.5 db. Causes of the differences were found to be mainly related to different spectrum extrapolation and preemphasis techniques used by the two groups.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khan, E.U.; George, T.L.; Rector, D.R.
The natural circulation tests of the Fast Flux Test Facility (FFTF) demonstrated a safe and stable transition from forced convection to natural convection and showed that natural convection may adequately remove decay heat from the reactor core. The COBRA-WC computer code was developed by the Pacific Northwest laboratory (PNL) to account for buoyancy-induced coolant flow redistribution and interassembly heat transfer, effects that become important in mitigating temperature gradients and reducing reactor core temperatures when coolant flow rate in the core is low. This report presents work sponsored by the US Department of Energy (DOE) with the objective of checking themore » validity of COBRA-WC during the first 220 seconds (sec) of the FFTF natural-circulation (plant-startup) tests using recorded data from two instrumented Fuel Open Test Assemblies (FOTAs). Comparison of COBRA-WC predictions of the FOTA data is a part of the final confirmation of the COBRA-WC methodology for core natural-convection analysis.« less
Version 2.0 Visual Sample Plan (VSP): UXO Module Code Description and Verification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilbert, Richard O.; Wilson, John E.; O'Brien, Robert F.
2003-05-06
The Pacific Northwest National Laboratory (PNNL) is developing statistical methods for determining the amount of geophysical surveys conducted along transects (swaths) that are needed to achieve specified levels of confidence of finding target areas (TAs) of anomalous readings and possibly unexploded ordnance (UXO) at closed, transferring and transferred (CTT) Department of Defense (DoD) ranges and other sites. The statistical methods developed by PNNL have been coded into the UXO module of the Visual Sample Plan (VSP) software code that is being developed by PNNL with support from the DoD, the U.S. Department of Energy (DOE, and the U.S. Environmental Protectionmore » Agency (EPA). (The VSP software and VSP Users Guide (Hassig et al, 2002) may be downloaded from http://dqo.pnl.gov/vsp.) This report describes and documents the statistical methods developed and the calculations and verification testing that have been conducted to verify that VSPs implementation of these methods is correct and accurate.« less
Site-specific investigations on aquifer thermal energy storage for space and process cooling
NASA Astrophysics Data System (ADS)
Brown, D. R.
1991-08-01
The Pacific Northwest Laboratory (PNL) has completed three preliminary site-specific feasibility studies that investigated aquifer thermal energy storage (ATES) for reducing space and process cooling costs. Chilled water stored in an ATES system could be used to meet all or part of the process and/or space cooling loads at the three facilities investigated. Seasonal or diurnal chill ATES systems could be significantly less expensive than a conventional electrically-driven, load-following chiller system at one of the three sites, depending on the cooling water loop return temperature and presumed future electricity escalation rate. For the other two sites investigated, a chill ATES system would be economically competitive with conventional chillers if onsite aquifer characteristics were improved. Well flow rates at one of the sites were adequate, but the expected thermal recovery efficiency was too low. The reverse of this situation was found at the other site, where the thermal recovery efficiency was expected to be adequate, but well flow rates were too low.
Wildlife studies on the Hanford Site: 1993 Highlights report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cadwell, L.L.
The Pacific Northwest Laboratory (PNL) Wildlife Resources Monitoring Project was initiated by DOE to track the status of wildlife populations to determine whether Hanford operations affected them. The project continues to conduct a census of wildlife populations that are highly visible, economically or aesthetically important, and rare or otherwise considered sensitive. Examples of long-term data collected and maintained through the Wildlife Resources Monitoring Project include annual goose nesting surveys conducted on islands in the Hanford Reach, wintering bald eagle surveys, and fall Chinook salmon redd (nest) surveys. The report highlights activities related to salmon and mollusks on the Hanford Reachmore » of the Columbia River; describes efforts to map vegetation on the Site and efforts to survey species of concern; provides descriptions of shrub-steppe bird surveys, including bald eagles, Canada geese, and hawks; outlines efforts to monitor mule deer and elk populations on the Site; and describes development of a biological database management system.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yavuz, M.
1999-05-01
In the 1970s at the Battelle Pacific Northwest Laboratory (PNL), a series of critical experiments using a remotely operated Split-Table Machine was performed with homogeneous mixtures of (Pu-U)O{sub 2}-polystyrene fuels in the form of square compacts having different heights. The experiments determined the critical geometric configurations of MOX fuel assemblies with and without neutron poison plates. With respect to PuO{sub 2} content and moderation [H/(Pu+U)atomic] ratio (MR), two different homogeneous (Pu-U) O{sub 2}-polystyrene mixtures were considered: Mixture (1) 14.62 wt% PuO{sub 2} with 30.6 MR, and Mixture (2) 30.3 wt% PuO{sub 2} with 2.8 MR. In all mixtures, the uraniummore » was depleted to about O.151 wt% U{sup 235}. Assemblies contained copper, copper-cadmium or aluminum neutron poison plates having thicknesses up to {approximately}2.5 cm. This evaluation contains 22 experiments for Mixture 1, and 10 for Mixture 2 compacts. For Mixture 1, there are 10 configurations with copper plates, 6 with aluminum, and 5 with copper-cadmium. One experiment contained no poison plate. For Mixture 2 compacts, there are 3 configurations with copper, 3 with aluminum, and 3 with copper-cadmium poison plates. One experiment contained no poison plate.« less
Does the presence of hydronephrosis have effects on micropercutaneous nephrolithotomy?
Karatag, Tuna; Buldu, Ibrahim; Kaynar, Mehmet; Inan, Ramazan; Istanbulluoglu, Mustafa Okan
2015-03-01
To evaluate the effects of presence of hydronephrosis on micropercutaneous nephrolithotomy (micro-PNL) surgery. A retrospective analysis of 112 patients who underwent microperc surgery between December 2012 and April 2014 was performed. Patients were evaluated in two groups according to whether the presence of hydronephrosis. Stone size and location, fluoroscopy and operation time, stone-free rates and patient-related parameters were prospectively recorded into a centralized computer-generated system. A total of 58 patients in Group 1 with hydronephrosis and 54 patients in Group 2 with no hydronephrosis were analyzed. There was no statistically significant difference in terms of stone sizes and body mass indexes (BMI) in comparison of groups (155.2 ± 93.06 vs. 143.70 ± 70.77 mm(2), p = 0.856 and 27.6 ± 4.2 vs. 26.7 ± 3.2 kg/m(2), p = 0.625). The success rates were similar (91.3 vs. 92.5%, p = 0.341). While the mean operation time and fluoroscopy time in Group 1 were 44.2 ± 23.62 min and 105.3 ± 47 s, it was 38.8 ± 26.4 min and 112.53 ± 68.3 s in Group 2, but there was no statistical difference in comparison of both groups. The mean attempts of percutan puncture were 1.35 ± 0.47 in Group 1 and 1.76 ± 0.31 in Group 2 (p = 0.185). We also found no statistical differences regarding mean hemoglobin change and hospitalization time, respectively (p = 0.685 and p = 0753). In comparison of grades of hydronephrosis, there was no statistically significant difference in subgroups analysis. The presence of hydronephrosis does not affect success rates and operative time in micro-PNL procedures significantly. Micropercutaneous nephrolithotomy is technically feasible and efficacious both in hydronephrotic and non-hydronephrotic kidneys.
In Vivo Monitoring Program Manual, PNL-MA-574, Rev 5.1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lynch, Timothy P.
2011-09-12
The following sections provide an overview of the administration for the In Vivo Monitoring Program (IVMP) for Hanford. This includes the organizational structure and program responsibilities; coordination of in vivo measurements; scheduling measurements; performing measurements; reporting results; and quality assurance.
Thayabaran, M; Yasawardene, S G
2015-12-01
Although the local inflammatory reactions are known to be regulated through cholinergic anti-inflammatory pathways, the exact subtypes of nicotinic acetylcholine receptors involved in neuroimmune modulation are not well identified. Immunohistochemical localisation of a1 subunit of nicotinic acetylcholine receptors (a1nAChR) in sites of localised inflammation induced by injecting turpentine to the hind limbs of Balb/C mice. Localised inflammation and subsequent development of sterile abscesses was induced by injecting sterile turpentine subcutaneously into thighs of Balb/C mice. Sterile saline was used in the control.. Skin and muscle tissues of inflammatory sites were recovered from the animals after 48 hours and were stained with hematoxylin and eosin. Indirect immunohistochemistry was done using anti-a1nAChR as the primary antibody and biotinylated anti-rat IgG as the secondary antibody. Labeled streptavidin biotin (LSAB) technique was used with diaminobenzedene to detect the immunoreactivity (IR). Intensity of immunostaining was determined based upon a score of 0 - 3+ by qualitative computerised image analysis using FSX 100 Olympus microscope. H and E stained slides showed polymorphonuclear leukocytes (PNL) infiltration at the abscess sites while the saline injected control tissue sections did not show PNL infiltration. A 2+ immunoreactivity (IR) of a1nAChRs was visible at peripheral zones of sterile abscesses where PNL infiltrations were high while the central area with necrotic tissue did not show IR. A subcutaneous lymph node found within the inflammatory region expressed IR of a1nAChR in its capsular sinuses, subcapsular sinuses and trabecular regions. The findings suggest the possible role of controlling localised inflammatory response by parasympathetic cholinergic nerves through a1nAChRs of inflammation sites.
Haggag, Yasser M.; Morsy, Gamal; Badr, Magdy M.; Al Emam, Abdel Baset A.; Farid, Mourad; Etafy, Mohamed
2013-01-01
Background The aim of the study is to investigate whether laparoscopic pyelolithotomy (LPL) could be used to manage large renal pelvic stones, generally considered excellent indications for percutaneous nephrolithotomy (PNL). Methods: This study was performed from May 2009 to March 2012 at Al-Azhar University Hospitals (Assiut and Cairo), Egypt. It included two groups of patients with large renal pelvic stones; only patients with stones 2.5 cm2 or greater were included. Group 1 included 40 patients treated by PNL and Group 2 included 10 patients treated by LPL. The differences between the two procedures were compared and analyzed. Results: There was no difference between the two groups regarding patient demographics and stone size. There was a statistically significant difference between the groups regarding mean estimated blood loss (65 ± 12.25 [range: 52.75–77.25] vs. 180 ± 20.74 [range: 159.26–200.74] mL, p ≤ 0001), mean hospital stay (2.3 ± 0.64 [range: 1.66–2.94] vs. 3.7 ± 1.4 [range: 2.3–5.1] days, p ≤ 0.006), rate of postoperative blood transfusion (0% vs. 4.8%, p ≤ 0.0024), and stone-free rate (80% vs. 78.6%, p ≤ 0.23). The mean operative time was significantly longer in Group 2 (LPL) (131 ± 22.11 [range: 108.89–153.11) vs. 51.19 ± 24.39 [range: 26.8–75.58] min, p ≤ 0001), respectively. Conclusion: Although PNL is the standard treatment in most cases of renal pelvic stones, LPL is another feasible surgical technique for patients with large renal pelvic stones. PMID:23589752
Rapid Regional Centroid Solutions
NASA Astrophysics Data System (ADS)
Wei, S.; Zhan, Z.; Luo, Y.; Ni, S.; Chen, Y.; Helmberger, D. V.
2009-12-01
The 2008 Wells Nevada Earthquake was recorded by 164 broadband USArray stations within a distance of 550km (5 degrees) with all azimuths uniformly sampled. To establish the source parameters, we applied the Cut and Paste (CAP) code to all the stations to obtain a mechanism (strike/dip/rake=35/41/-85) at a depth of 9km and Mw=5.9. Surface wave shifts range from -8s to 8s which are in good agreement with ambient seismic noise (ASN) predictions. Here we use this data set to test the accuracy of the number of stations needed to obtain adequate solutions (position of the compressional and tension axis) for mechanism. The stations were chosen at random where combinations of Pnl and surface waves were used to establish mechanism and depth. If the event is bracketed by two stations, we obtain an accurate magnitude with good solutions about 80% of the trials. Complete solutions from four stations or Pnl from 10 stations prove reliable in nearly all situations. We also explore the use of this dataset in locating the event using a combination of surface wave travel times and/or the full waveform inversion (CAPloc) that uses the CAP shifts to refine locations. If the mechanism is known (fixed) only a few stations is needed to locate an event to within 5km if date is available at less than 150km. In contrast, surface wave travel times (calibrated to within one second) produce amazing accurate locations with only 6 stations reasonably distributed. It appears this approach is easily automated as suggested by Scrivner and Helmberger (1995) who discussed travel times of Pnl and surface waves and the evolving of source accuracy as the various phases arrive.
Basta, Tamara; Keck, Andreas; Klein, Joachim; Stolz, Andreas
2004-01-01
A systematic survey for the presence of plasmids in 17 different xenobiotic-degrading Sphingomonas strains was performed. In almost all analyzed strains, two to five plasmids with sizes of about 50 to 500 kb were detected by using pulsed-field gel electrophoresis. A comparison of plasmid preparations untreated or treated with S1 nuclease suggested that, in general, Sphingomonas plasmids are circular. Hybridization experiments with labeled gene probes suggested that large plasmids are involved in the degradation of dibenzo-p-dioxin, dibenzofuran, and naphthalenesulfonates in S. wittichii RW1, Sphingomonas sp. HH69, and S. xenophaga BN6, respectively. The plasmids which are responsible for the degradation of naphthalene, biphenyl, and toluene by S. aromaticivorans F199 (pNL1) and of naphthalenesulfonates by S. xenophaga BN6 (pBN6) were site-specifically labeled with a kanamycin resistance cassette. The conjugative transfer of these labeled plasmids was attempted with various bacterial strains as putative recipient strains. Thus, a conjugative transfer of plasmid pBN6 from S. xenophaga BN6 to a cured mutant of strain BN6 and to Sphingomonas sp. SS3 was observed. The conjugation experiments with plasmid pNL1 suggested a broader host range of this plasmid, because it was transferred without any obvious structural changes to S. yanoikuyae B1, Sphingomonas sp. SS3, and S. herbicidovorans. In contrast, major plasmid rearrangements were observed in the transconjugants after the transfer of plasmid pNL1 to Sphingomonas sp. HH69 and of pBN6 to Sphingomonas sp. SS3. No indications for the transfer of a Sphingomonas plasmid to bacteria outside of the Sphingomonadaceae were obtained. PMID:15175300
Predictors of radiation exposure to providers during percutaneous nephrolithotomy
Wenzler, David L.; Abbott, Joel E.; Su, Jeannie J.; Shi, William; Slater, Richard; Miller, Daniel; Siemens, Michelle J.; Sur, Roger L.
2017-01-01
Background: Limited studies have reported on radiation risks of increased ionizing radiation exposure to medical personnel in the urologic community. Fluoroscopy is readily used in many urologic surgical procedures. The aim of this study was to determine radiation exposure to all operating room personnel during percutaneous nephrolithotomy (PNL), commonly performed for large renal or complex stones. Materials and Methods: We prospectively collected personnel exposure data for all PNL cases at two academic institutions. This was collected using the Instadose™ dosimeter and reported both continuously and categorically as high and low dose using a 10 mrem dose threshold, the approximate amount of radiation received from one single chest X-ray. Predictors of increased radiation exposure were determined using multivariate analysis. Results: A total of 91 PNL cases in 66 patients were reviewed. Median surgery duration and fluoroscopy time were 142 (38–368) min and 263 (19–1809) sec, respectively. Median attending urologist, urology resident, anesthesia, and nurse radiation exposure per case was 4 (0–111), 4 (0–21), 0 (0–5), and 0 (0–5) mrem, respectively. On univariate analysis, stone area, partial or staghorn calculi, surgery duration, and fluoroscopy time were associated with high attending urologist and resident radiation exposure. Preexisting access that was utilized was negatively associated with resident radiation exposure. However, on multivariate analysis, only fluoroscopy duration remained significant for attending urologist radiation exposure. Conclusion: Increased stone burden, partial or staghorn calculi, surgery and fluoroscopy duration, and absence of preexisting access were associated with high provider radiation exposure. Radiation safety awareness is essential to minimize exposure and to protect the patient and all providers from potential radiation injury. PMID:28216931
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scheele, R.D.
In 1995, available subsegment samples of wastes taken from the Hanford Site underground radioactive waste storage tanks 241-C-112 (C-112) and 241-C-109 (C-109) were reanalyzed to determine the nickel concentrations in the samples and to determine whether the use of a nickel crucible in the analytical sample preparation biased the reported nickel concentrations reported by Simpson and coworkers and in the original report that this report supplements. The reanalysis strategy to determine nickel was to use a sodium peroxide flux in a zirconium crucible instead of the previously used potassium hydroxide flux in a nickel crucible. This supplemental report provides themore » results of the reanalyses and updates tables from the original report which reflect the new nickel analyses. Nickel is important with respect to management of the potentially reactive ferrocyanide wastes as it is one of the key defining characteristics of the solids that resulted from scavenging radiocesium using ferrocyanides. In Hanford Site wastes, few other processes introduced nickel into the wastes other than radiocobalt scavenging, which was often coupled with the ferrocyanide-scavenging process. Thus the presence of nickel in a waste provides strong evidence that the original waste was or contained ferrocyanide waste at one time. Given the potential import of nickel as a defining characteristic and marker for ferrocyanide wastes, the Pacific Northwest Laboratory`s (PNL) Analytical Chemistry Laboratory (ACL) reanalyzed available samples from tanks C-112 and C-109 using inductively coupled argon plasma/atomic emission spectrometry (ICP/AES) and an alternative sample preparation method which precluded contamination of the analytical samples with nickel.« less
NASA Astrophysics Data System (ADS)
Rodgers, Arthur J.; Schwartz, Susan Y.
We report low average crustal P-wave velocities (5.9-6.1 km/s, Poisson's ratio 0.23-0.27, thickness 68-76 km) in southern Tibet from modelling regional Pnl waveforms recorded by the 1991-1992 Tibetan Plateau Experiment. We also find that the mantle lithosphere beneath the Indus-Tsangpo Suture and the Lhasa Terrane is shield-like (Pn velocity 8.20-8.25 km/s, lid thickness 80-140 km, positive velocity gradient 0.0015-0.0025 s-1). Analysis of relative Pn travel time residuals requires a decrease in the mantle velocities beneath the northern Lhasa Terrane, the Banggong-Nujiang Suture and the southern Qiangtang Terrane. Tectonic and petrologic considerations suggest that low bulk crustal velocities could result from a thick (50-60 km) felsic upper crust with vertically limited and laterally pervasive partial melt. These results are consistent with underthrusting of Indian Shield lithosphere beneath the Tibetan Plateau to at least the central Lhasa Terrane.
[Effects of percutaneous nephrolithotomy in the treatment of medullary sponge kidney with calculi].
Hong, Y; Xu, Q Q; Huang, X B; Zhu, Z J; Ye, H Y; Zhang, F S; Yang, Q Y; An, L Z; Xu, T
2017-10-01
Objective: To evaluate the effects of percutaneous nephrolithotomy (PNL) in the treatment of medullary sponge kidney with calculi. Methods: A total of 77 patients (91 renal units) of medullary sponge kidney with calculi (MSK group) and 77 patients (77 renal units) with common kidney stone (control group) received PNL at Department of Urology in Peking University People's Hospital from September 2006 to February 2016 were analyzed retrospectively. The MSK group included 33 males and 44 females with a mean age of (42.1±13.2) years, the mean stone burden was (3.9±1.8) cm. The control group included 36 males and 41 females with a mean age of (45.3±13.0) years, the mean stone burden was (3.6±1.5) cm. The numbers of tracts, the time of operation, the drop of hemoglobin, the change of creatine, the time of hospitalization, the stone free rate and major complications were compared between the two groups. The measurement data and numeration data were compared with t test and χ(2) test. Results: There were no significant differences in sex, age, preoperative urinary tract infection, stone type, and stone burden between the two groups (all P >0.05). The proportion of bilateral renal calculus in MSK group was higher (18.2% vs . 0, χ(2)=15.400, P =0.000). There were 159 percutaneous channels were established in MSK group while 90 percutaneous channels were established in control group. Compared with the control group, the operation time ((88.1±37.5) minutes vs . (68.5±30.1) minutes, t =3.543, P =0.000) and hospitalization time ((15.1±8.3) days vs . (10.1±3.6) days, t =4.816, P =0.000) were longer, the creatinine level increased ((101.2±62.6) μmol/L vs . (71.3±23.6) μmol/L, t =3.777, P =0.000), the rate of stone free decreased (27.5% vs . 83.1%, χ(2)=51.840, P =0.000) and the rate of complications increased (29.9% vs . 11.7%, χ(2)=8.114, P =0.004) in MSK group. There was no statistically difference in hemoglobin drop ((12.5±13.2) g/L vs . (13.0±10.9) g/L, t =-0.260, P =0.795). Conclusions: Using PNL for patients of MSK with calculi has a lower stone free rate and a higher complications. It is an effective method for patients of MSK with large and complex calculi.
Vegetation survey of knapweed on the Yakima Training Center - 1992
DOE Office of Scientific and Technical Information (OSTI.GOV)
Downs, J.L.; Cadoret, N.A.; Rickard, W.H.
1994-04-01
This report summarizes and discusses the results of a vegetation survey conducted in 1992 on a portion of the Yakima Training Center (YTC). Pacific Northwest Laboratory (PNL) conducted this survey and a similar survey in 1991 for the U.S. Department of the Army. The objectives of the survey were to evaluate the impact of the herbicide picloram on forbs where aerial applications of picloram were made in 1988, 1989, and 1991 to control knapweed infestations. Forbs are of special interest because they are an important part of the spring and summer diet of the western sage grouse, which is amore » U.S. Fish and Wildlife Service candidate species for the threatened and endangered list. We also conducted a limited evaluation of the effectiveness of the spray program in controlling the spread of knapweed. Percent plant canopy cover and number of forbs were measured on 120 transacts on the herbicide-treated and untreated control areas. Herbicide treatment in 1991 resulted in a significant reduction in knapweed based on percent cover and density. The treatment areas also all had lower percent canopy cover of perennial forbs and fewer perennial forbs compared to control areas. Canopy cover of shrubs and annual, biennial, and perennial forbs measured on the YTC increased between the 1991 and 1992 survey, which may indicate a recovery of these vegetation types after disturbance. These increases also could reflect the mild 1992 winter and superior growing conditions in the spring of 1992. We recommend that these vegetation transacts continue to be monitored for an additional growing season to evaluate (1) whether knapweed increases to its previous abundance in the 1991 herbicide-treated area, (2) the efficacy of herbicide application on transacts along roadways, and (3) the increase in invasive annuals in herbicide-treated areas and the possible effects on community vegetation structure and sage grouse habitat.« less
Hamamoto, Shuzo; Yasui, Takahiro; Okada, Atsushi; Koiwa, Satoshi; Taguchi, Kazumi; Itoh, Yasunori; Kawai, Noriyasu; Hashimoto, Yoshihiro; Tozawa, Keiichi; Kohri, Kenjiro
2015-01-01
Abstract Purpose: To evaluate the efficacy of endoscopic combined intrarenal surgery (ECIRS) using retrograde flexible ureteroscopy and miniature percutaneous nephrolithotomy (PNL) for the treatment of patients with staghorn calculi in the prone split-leg position. We retrospectively reviewed the records of 42 patients with staghorn calculi (45.8±3.2 mm) who underwent ECIRS using retrograde flexible ureteroscopy and miniature PNL in the prone split-leg position for the treatment of staghorn calculi in our center between December 2010 and August 2013. A flexible ureteroscope with a laser fiber was inserted through a ureteral access sheath, and lithoclast lithotripsy was performed through a mini-percutaneous tract. Both procedures were performed simultaneously by two urologists. Surgical parameters, including surgical time, stone-free (SF) rates, modified Clavien complication grades, and risk factors for residual stones, were analyzed. Fifteen patients (35.7%) had complete staghorn calculi. Among the 42 staghorn calculi treated, 23 had 0 to 5 stone branches, 14 had 6 to 10 stone branches, and 5 had ≥11 stone branches. All procedures were performed successfully using a single lithotripsy tract with the patient in the prone split-leg position. The mean surgical time was 143.2±9.2 minutes. The initial SF rate was 71.4%, and the final SF rate was 83.3% after further treatment. One patient required a blood transfusion (2.4%), but no patient experienced a ≥3 Clavien grade complication. Risk factors for residual stones were stone size, stone surface area, complete staghorn calculi, and the number of stone branches. ECIRS for staghorn calculi in the prone split-leg position is a safe, efficient, and versatile method for the effective management of staghorn calculi without the creation of multiple percutaneous tracts.
Hanford Environmental Dose Reconstruction Project Monthly Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Finch, S.M.
1991-02-01
The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation doses that populations could have received from nuclear operations at Hanford since 1944. The project is being managed and conducted by the Pacific Northwest Laboratory (PNL) under the direction of an independent Technical Steering Panel (TSP). The TSP consists of experts in environmental pathways, epidemiology, surface-water transport, ground-water transport, statistics, demography, agriculture, meteorology, nuclear engineering, radiation dosimetry, and cultural anthropology. Included are appointed technical members representing the states of Oregon and Washington, cultural and technical experts nominated by the regional Native American tribes, and an individualmore » representing the public. The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed, from release to impact on humans (dose estimates): source terms; environmental transport; environmental monitoring data; demographics, agriculture, food habits; and environmental pathways and dose estimates. Project reports and references used in the reports are made available to the public in a public reading room. Project progress is documented in this monthly report, which is available to the public. 3 figs., 3 tabs.« less
Observations and Modeling for Source Characterization
2011-02-25
Sequim Bay Road Sequim , WA 98382 Phone: (360) 681 -3616 Fax: (360) 681 -3699 Email: lyle.hibler@pnl.gov Grant Number: N00014-08-1-0508 LONG...currents south of the opening of San Diego Bay show a northerly propagation resulting in an eddy off of Point Loma. The currents around the Tijuana
Diagnostics for a waste processing plasma arc furnace (invited) (abstract)a)
NASA Astrophysics Data System (ADS)
Woskov, P. P.
1995-01-01
Maintaining the quality of our environment has become an important goal of society. As part of this goal new technologies are being sought to clean up hazardous waste sites and to treat ongoing waste streams. A 1 MW pilot scale dc graphite electrode plasma arc furnace (Mark II) has been constructed at MIT under a joint program among Pacific Northwest Laboratory (PNL), MIT, and Electro-Pyrolysis, Inc. (EPI)c) for the remediation of buried wastes in the DOE complex. A key part of this program is the development of new and improved diagnostics to study, monitor, and control the entire waste remediation process for the optimization of this technology and to safeguard the environment. Continuous, real time diagnostics are needed for a variety of the waste process parameters. These parameters include internal furnace temperatures, slag fill levels, trace metals content in the off-gas stream, off-gas molecular content, feed and slag characterization, and off-gas particulate size, density, and velocity distributions. Diagnostics are currently being tested at MIT for the first three parameters. An active millimeter-wave radiometer with a novel, rotatable graphite waveguide/mirror antenna system has been implemented on Mark II for the measurement of surface emission and emissivity which can be used to determine internal furnace temperatures and fill levels. A microwave torch plasma is being evaluated for use as a excitation source in the furnace off-gas stream for continuous atomic emission spectroscopy of trace metals. These diagnostics should find applicability not only to waste remediation, but also to other high temperature processes such as incinerators, power plants, and steel plants.
On-Orbit Demonstration of a Lithium-Ion Capacitor and Thin-Film Multijunction Solar Cells
NASA Astrophysics Data System (ADS)
Kukita, Akio; Takahashi, Masato; Shimazaki, Kazunori; Kobayashi, Yuki; Sakai, Tomohiko; Toyota, Hiroyuki; Takahashi, Yu; Murashima, Mio; Uno, Masatoshi; Imaizumi, Mitsuru
2014-08-01
This paper describes an on-orbit demonstration of the Next-generation Small Satellite Instrument for Electric power systems (NESSIE) on which an aluminum- laminated lithium-ion capacitor (LIC) and a lightweight solar panel called KKM-PNL, which has space solar sheets using thin-film multijunction solar cells, were installed. The flight data examined in this paper covers a period of 143 days from launch. We verified the integrity of an LIC constructed using a simple and lightweight mounting method: no significant capacitance reduction was observed. We also confirmed that inverted metamorphic multijunction triple-junction thin-film solar cells used for evaluation were healthy at 143 days after launch, because their degradation almost matched the degradation predictions for dual-junction thin-film solar cells.
CASMO5 JENDL-4.0 and ENDF/B-VII.1beta4 libraries
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rhodes, J.; Gheorghiu, N.; Ferrer, R.
2012-07-01
This paper details the generation of neutron data libraries for the CASMO5 lattice physics code based on the recently released JENDL-4.0 and ENDF/B-VII.1beta4 nuclear data evaluations. This data represents state-of-the-art nuclear data for late-2011. The key features of the new evaluations are briefly described along with the procedure for processing of this data into CASMO5, 586-energy group neutron data libraries. Finally some CASMO5 results for standard UO{sub 2} and MOX critical experiments for the two new libraries and the current ENDF/B-VII.0 CASMO5 library are presented including the B and W 1810 series, DIMPLE S06A, S06B, TCA reflector criticals with ironmore » plates and the PNL-30-35 MOX criticals. The results show that CASMO5 with the new libraries is performing well for these criticals with a very slight edge in results to the JENDL-4.0 nuclear data evaluation over the ENDF/B-VII.1beta4 evaluation. Work is currently underway to generate a CASMO5 library based on the final ENDF/B-VII.R1 evaluation released Dec. 22, 2011. (authors)« less
U.S. EPA, Pesticide Product Label, MBC CONCENTRATE SOIL FUMIGANT, 08/25/1998
2011-04-21
... (,,10011 eqlllpl\\\\elll rnll~1
Partnership for a Nation of Learners: Joining Forces, Creating Value
ERIC Educational Resources Information Center
Kulpinski, Dan
2009-01-01
This publication presents in-depth profiles of six high-performing partnerships funded by the Partnership for a Nation of Learners (PNL) and short profiles of the remaining grantees. The partnerships illustrate a range of examples of how museums, libraries, public broadcasters, and other vital community organizations can collaborate to address…
24 CFR 3280.508 - Heat loss, heat gain and cooling load calculations.
Code of Federal Regulations, 2013 CFR
2013-04-01
... Thermal Protection § 3280.508 Heat loss, heat gain and cooling load calculations. (a) Information, values... Loads—Manufactured Homes—February 1992-PNL 8006, HUD User No. 0005945. (c) Areas where the insulation... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Heat loss, heat gain and cooling...
24 CFR 3280.508 - Heat loss, heat gain and cooling load calculations.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Thermal Protection § 3280.508 Heat loss, heat gain and cooling load calculations. (a) Information, values... Loads—Manufactured Homes—February 1992-PNL 8006, HUD User No. 0005945. (c) Areas where the insulation... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Heat loss, heat gain and cooling...
24 CFR 3280.508 - Heat loss, heat gain and cooling load calculations.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Thermal Protection § 3280.508 Heat loss, heat gain and cooling load calculations. (a) Information, values... Loads—Manufactured Homes—February 1992-PNL 8006, HUD User No. 0005945. (c) Areas where the insulation... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Heat loss, heat gain and cooling...
24 CFR 3280.508 - Heat loss, heat gain and cooling load calculations.
Code of Federal Regulations, 2012 CFR
2012-04-01
... Thermal Protection § 3280.508 Heat loss, heat gain and cooling load calculations. (a) Information, values... Loads—Manufactured Homes—February 1992-PNL 8006, HUD User No. 0005945. (c) Areas where the insulation... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Heat loss, heat gain and cooling...
24 CFR 3280.508 - Heat loss, heat gain and cooling load calculations.
Code of Federal Regulations, 2014 CFR
2014-04-01
... Thermal Protection § 3280.508 Heat loss, heat gain and cooling load calculations. (a) Information, values... Loads—Manufactured Homes—February 1992-PNL 8006, HUD User No. 0005945. (c) Areas where the insulation... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Heat loss, heat gain and cooling...
A subjective evaluation of synthesized STOL airplane noises
NASA Technical Reports Server (NTRS)
Powell, C. A., Jr.
1973-01-01
A magnitude-estimation experiment was conducted to evaluate the subjective annoyance of the noise generated by possible future turbofan STOL aircraft as compared to that of several current CTOL aircraft. In addition, some of the units used to scale the magnitude of aircraft noise were evaluated with respect to their applicability to STOL noise. Twenty test subjects rated their annoyance to a total of 119 noises over a range of 75 PNdb to 105 PNdb. Their subjective ratings were compared with acoustical analysis of the noises in terms of 28 rating scale units. The synthesized STOL noises of this experiment were found to be slightly more annoying than the conventional CTOL noises at equal levels of PNL and EPNL. Over the range of levels investigated the scaling units, with a few exceptions, were capable of predicting the points of equal annoyance for all of the noises with plus or minus 3 dB. The inclusion of duration corrections, in general, improved the predictive capabilities of the various scaling units; however, tone corrections reduced their predictive capabilities.
Assessment at full scale of exhaust nozzle-to-wing size on STOL-OTW acoustic characteristics
NASA Technical Reports Server (NTRS)
Von Glahn, U.; Groesbeck, D.
1979-01-01
On the basis of static zero/acoustic data obtained at model scale, the effect of exhaust nozzle size on flyover noise is evaluated at full scale for different STOL-OTW nozzle configurations. Three types of nozzles are evaluated: a circular/deflector nozzle mounted above the wing, a slot/deflector nozzle mounted on the wing, and a slot nozzle mounted on the wing. The nozzle exhaust plane location, measured from the wing leading edge was varied from 10 to 46 percent of the wing chord (flaps retracted). Flap angles of 20 deg (takeoff) and 60 deg (approach) are included in the study. Initially, perceived noise levels (PNL) are calculated as a function of flyover distance at 152 m altitude. From these plots static EPNL values, defined as flyover relative noise levels, then are obtained as functions of nozzle size for equal aerodynamic performance (lift and thrust). On the basis of these calculations, the acoustic benefits attributable to nozzle size relative to a given wing chord size are assessed.
Assessment at full scale of exhaust nozzle to wing size on STOL-OTW acoustic characteristics
NASA Technical Reports Server (NTRS)
Vonglahn, U.; Grosbeck, D.
1979-01-01
On the basis of static aero/acoustic data obtained at model scale, the effect of exhaust nozzle size on flyover noise is evaluated at full scale for different STOL-OTW nozzle configurations. Three types of nozzles are evaluated: a circular/deflector nozzle mounted above the wing; a slot/deflector nozzle mounted on the wing; and a slot nozzle mounted on the wing. The nozzle exhaust plane location, measured from the wing leading edge, was varied from 10 to 46 percent of the wing chord (flaps retracted). Flap angles of 20 deg (takeoff) and 60 deg (approach) are included in the study. Initially, perceived noise levels (PNL) are calculated as a function flyover distance at 152m altitude. From these plots, static EPNL values (defined as flyover relative noise levels), are obtained as functions of nozzle size for equal aerodynamic performance (lift and thrust). The acoustic benefits attributable to nozzle size relative to a given wing chord size are assessed.
Selective separation of Eu{sup 3+} using polymer-enhanced ultrafiltration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Norton, M.V.
1994-03-01
A process to selectively remove {sup 241}Am from liquid radioactive waste was investigated as an actinide separation method applicable to Hanford and other waste sites. The experimental procedures involved removal of Eu, a nonradioactive surrogate for Am, from aqueous solutions at pH 5 using organic polymers in conjunction with ultrafiltration. Commercially available polyacrylic acid (60,000 MW) and Pacific Northwest Laboratory`s (PNL) synthesized E3 copolymer ({approximately}10,000 MW) were tested. Test solutions containing 10 {mu}g/mL of Eu were dosed vath each polymer at various concentrations in order to bind Eu (i.e., by complexation and/or cation exchange) for subsequent rejection by an ultrafiltrationmore » coupon. Test solutions were filtered with and without polymer to determine if enhanced Eu separation could be achieved from polymer treatment. Both polymers significantly increased Eu removal. Optimum concentrations were 20 {mu}g/mL of polyacrylic acid and 100 {mu}g/mL of E3 for 100% Eu rejection by the Amicon PM10 membrane at 55 psi. In addition to enhancement of removal, the polymers selectively bound Eu over Na, suggesting that selective separation of Eu was possible. This suggests that polymer-enhanced ultrafiltration is a potential process for separation of {sup 241}Am from Hanford tank waste, further investigation of binding agents and membranes effective under very alkaline and high ionic strength is warranted. This process also has potential applications for selective separation of toxic metals from industrial process streams.« less
Bukowski, Radek; Sadovsky, Yoel; Goodarzi, Hani; Zhang, Heping; Biggio, Joseph R; Varner, Michael; Parry, Samuel; Xiao, Feifei; Esplin, Sean M; Andrews, William; Saade, George R; Ilekis, John V; Reddy, Uma M; Baldwin, Donald A
2017-01-01
Preterm birth is a main determinant of neonatal mortality and morbidity and a major contributor to the overall mortality and burden of disease. However, research of the preterm birth is hindered by the imprecise definition of the clinical phenotype and complexity of the molecular phenotype due to multiple pregnancy tissue types and molecular processes that may contribute to the preterm birth. Here we comprehensively evaluate the mRNA transcriptome that characterizes preterm and term labor in tissues comprising the pregnancy using precisely phenotyped samples. The four complementary phenotypes together provide comprehensive insight into preterm and term parturition. Samples of maternal blood, chorion, amnion, placenta, decidua, fetal blood, and myometrium from the uterine fundus and lower segment ( n = 183) were obtained during cesarean delivery from women with four complementary phenotypes: delivering preterm with (PL) and without labor (PNL), term with (TL) and without labor (TNL). Enrolled were 35 pregnant women with four precisely and prospectively defined phenotypes: PL ( n = 8), PNL ( n = 10), TL ( n = 7) and TNL ( n = 10). Gene expression data were analyzed using shrunken centroid analysis to identify a minimal set of genes that uniquely characterizes each of the four phenotypes. Expression profiles of 73 genes and non-coding RNA sequences uniquely identified each of the four phenotypes. The shrunken centroid analysis and 10 times 10-fold cross-validation was also used to minimize false positive finings and overfitting. Identified were the pathways and molecular processes associated with and the cis-regulatory elements in gene's 5' promoter or 3'-UTR regions of the set of genes which expression uniquely characterized the four phenotypes. The largest differences in gene expression among the four groups occurred at maternal fetal interface in decidua, chorion and amnion. The gene expression profiles showed suppression of chemokines expression in TNL, withdrawal of this suppression in TL, activation of multiple pathways of inflammation in PL, and an immune rejection profile in PNL. The genes constituting expression signatures showed over-representation of three putative regulatory elements in their 5'and 3' UTR regions. The results suggest that pregnancy is maintained by downregulation of chemokines at the maternal-fetal interface. Withdrawal of this downregulation results in the term birth and its overriding by the activation of multiple pathways of the immune system in the preterm birth. Complications of the pregnancy associated with impairment of placental function, which necessitated premature delivery of the fetus in the absence of labor, show gene expression patterns associated with immune rejection.
Sadovsky, Yoel; Goodarzi, Hani; Zhang, Heping; Biggio, Joseph R.; Varner, Michael; Parry, Samuel; Xiao, Feifei; Esplin, Sean M.; Andrews, William; Saade, George R.; Ilekis, John V.; Reddy, Uma M.; Baldwin, Donald A.
2017-01-01
Background Preterm birth is a main determinant of neonatal mortality and morbidity and a major contributor to the overall mortality and burden of disease. However, research of the preterm birth is hindered by the imprecise definition of the clinical phenotype and complexity of the molecular phenotype due to multiple pregnancy tissue types and molecular processes that may contribute to the preterm birth. Here we comprehensively evaluate the mRNA transcriptome that characterizes preterm and term labor in tissues comprising the pregnancy using precisely phenotyped samples. The four complementary phenotypes together provide comprehensive insight into preterm and term parturition. Methods Samples of maternal blood, chorion, amnion, placenta, decidua, fetal blood, and myometrium from the uterine fundus and lower segment (n = 183) were obtained during cesarean delivery from women with four complementary phenotypes: delivering preterm with (PL) and without labor (PNL), term with (TL) and without labor (TNL). Enrolled were 35 pregnant women with four precisely and prospectively defined phenotypes: PL (n = 8), PNL (n = 10), TL (n = 7) and TNL (n = 10). Gene expression data were analyzed using shrunken centroid analysis to identify a minimal set of genes that uniquely characterizes each of the four phenotypes. Expression profiles of 73 genes and non-coding RNA sequences uniquely identified each of the four phenotypes. The shrunken centroid analysis and 10 times 10-fold cross-validation was also used to minimize false positive finings and overfitting. Identified were the pathways and molecular processes associated with and the cis-regulatory elements in gene’s 5′ promoter or 3′-UTR regions of the set of genes which expression uniquely characterized the four phenotypes. Results The largest differences in gene expression among the four groups occurred at maternal fetal interface in decidua, chorion and amnion. The gene expression profiles showed suppression of chemokines expression in TNL, withdrawal of this suppression in TL, activation of multiple pathways of inflammation in PL, and an immune rejection profile in PNL. The genes constituting expression signatures showed over-representation of three putative regulatory elements in their 5′and 3′ UTR regions. Conclusions The results suggest that pregnancy is maintained by downregulation of chemokines at the maternal-fetal interface. Withdrawal of this downregulation results in the term birth and its overriding by the activation of multiple pathways of the immune system in the preterm birth. Complications of the pregnancy associated with impairment of placental function, which necessitated premature delivery of the fetus in the absence of labor, show gene expression patterns associated with immune rejection. PMID:28879060
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, J.F.
Research in the biomedical sciences at PNL is described. Activities reported include: inhaled plutonium in dogs; national radiobiology archives; statistical analysis of data from animal studies; genotoxicity of inhaled energy effluents; molecular events during tumor initiation; biochemistry of free radical induced DNA damage; radon hazards in homes; mechanisms of radon injury; genetics of radon induced lung cancer; and in vivo/in vitro radon induced cellular damage.
David Grant Medical Center energy use baseline and integrated resource assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richman, E.E.; Hoshide, R.K.; Dittmer, A.L.
1993-04-01
The US Air Mobility Command (AMC) has tasked Pacific Northwest Laboratory (PNL) with supporting the US Department of Energy (DOE) Federal Energy Management Program`s (FEMP) mission to identify, evaluate, and assist in acquiring all cost-effective energy resource opportunities (EROs) at the David Grant Medical Center (DGMC). This report describes the methodology used to identify and evaluate the EROs at DGMC, provides a life-cycle cost (LCC) analysis for each ERO, and prioritizes any life-cycle cost-effective EROs based on their net present value (NPV), value index (VI), and savings to investment ratio (SIR or ROI). Analysis results are presented for 17 EROsmore » that involve energy use in the areas of lighting, fan and pump motors, boiler operation, infiltration, electric load peak reduction and cogeneration, electric rate structures, and natural gas supply. Typical current energy consumption is approximately 22,900 MWh of electricity (78,300 MBtu), 87,600 kcf of natural gas (90,300 MBtu), and 8,300 gal of fuel oil (1,200 MBtu). A summary of the savings potential by energy-use category of all independent cost-effective EROs is shown in a table. This table includes the first cost, yearly energy consumption savings, and NPV for each energy-use category. The net dollar savings and NPV values as derived by the life-cycle cost analysis are based on the 1992 federal discount rate of 4.6%. The implementation of all EROs could result in a yearly electricity savings of more than 6,000 MWh or 26% of current yearly electricity consumption. More than 15 MW of billable load (total billed by the utility for a 12-month period) or more than 34% of current billed demand could also be saved. Corresponding natural gas savings would be 1,050 kcf (just over 1% of current consumption). Total yearly net energy cost savings for all options would be greater than $343,340. This value does not include any operations and maintenance (O&M) savings.« less
David Grant Medical Center energy use baseline and integrated resource assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richman, E.E.; Hoshide, R.K.; Dittmer, A.L.
1993-04-01
The US Air Mobility Command (AMC) has tasked Pacific Northwest Laboratory (PNL) with supporting the US Department of Energy (DOE) Federal Energy Management Program's (FEMP) mission to identify, evaluate, and assist in acquiring all cost-effective energy resource opportunities (EROs) at the David Grant Medical Center (DGMC). This report describes the methodology used to identify and evaluate the EROs at DGMC, provides a life-cycle cost (LCC) analysis for each ERO, and prioritizes any life-cycle cost-effective EROs based on their net present value (NPV), value index (VI), and savings to investment ratio (SIR or ROI). Analysis results are presented for 17 EROsmore » that involve energy use in the areas of lighting, fan and pump motors, boiler operation, infiltration, electric load peak reduction and cogeneration, electric rate structures, and natural gas supply. Typical current energy consumption is approximately 22,900 MWh of electricity (78,300 MBtu), 87,600 kcf of natural gas (90,300 MBtu), and 8,300 gal of fuel oil (1,200 MBtu). A summary of the savings potential by energy-use category of all independent cost-effective EROs is shown in a table. This table includes the first cost, yearly energy consumption savings, and NPV for each energy-use category. The net dollar savings and NPV values as derived by the life-cycle cost analysis are based on the 1992 federal discount rate of 4.6%. The implementation of all EROs could result in a yearly electricity savings of more than 6,000 MWh or 26% of current yearly electricity consumption. More than 15 MW of billable load (total billed by the utility for a 12-month period) or more than 34% of current billed demand could also be saved. Corresponding natural gas savings would be 1,050 kcf (just over 1% of current consumption). Total yearly net energy cost savings for all options would be greater than $343,340. This value does not include any operations and maintenance (O M) savings.« less
An analysis of decommissioning costs for the AFRRI TRIGA reactor facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Forsbacka, Matt
1990-07-01
A decommissioning cost analysis for the AFRRI TRIGA Reactor Facility was made. AFRRI is not at this time suggesting that the AFRRI TRIGA Reactor Facility be decommissioned. This report was prepared to be in compliance with paragraph 50.33 of Title 10, Code of Federal Regulations which requires the assurance of availability of future decommissioning funding. The planned method of decommissioning is the immediate decontamination of the AFRRI TRIGA Reactor site to allow for restoration of the site to full public access - this is called DECON. The cost of DECON for the AFRRI TRIGA Reactor Facility in 1990 dollars ismore » estimated to be $3,200,000. The anticipated ancillary costs of facility site demobilization and spent fuel shipment is an additional $600,000. Thus the total cost of terminating reactor operations at AFRRI will be about $3,800,000. The primary basis for this cost estimate is a study of the decommissioning costs of a similar reactor facility that was performed by Battelle Pacific Northwest Laboratory (PNL) as provided in USNRC publication NUREG/CR-1756. The data in this study were adapted to reflect the decommissioning requirements of the AFRRI TRIGA. (author)« less
NASA Astrophysics Data System (ADS)
Kim, Eugene; Larson, Timothy
A plume model is presented describing the downwind transport of large particles (1-100 μm) under stable conditions. The model includes both vertical variations in wind speed and turbulence intensity as well as an algorithm for particle deposition at the surface. Model predictions compare favorably with the Hanford single and dual tracer experiments of crosswind integrated concentration (for particles: relative bias=-0.02 and 0.16, normalized mean square error=0.61 and 0.14, for the single and dual tracer experiments, respectively), whereas the US EPA's fugitive dust model consistently overestimates the observed concentrations at downwind distances beyond several hundred meters (for particles: relative bias=0.31 and 2.26, mean square error=0.42 and 1.71, respectively). For either plume model, the measured ratio of particle to gas concentration is consistently overestimated when using the deposition velocity algorithm of Sehmel and Hodgson (1978. DOE Report PNL-SA-6721, Pacific Northwest Laboratories, Richland, WA). In contrast, these same ratios are predicted with relatively little bias when using the algorithm of Kim et al. (2000. Atmospheric Environment 34 (15), 2387-2397).
Why so few young women in mathematics, science, and technology classes?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wieda, K.J.
Many factors influence the success of women in scientific and technical careers. Women represent over 50% of the U.S. population, yet less than 16% of women are employed in scientific and technical careers. Research over the last decade makes it clear that disparities exist in the participation, achievement, and attitudes of young men and young women in science classes. Young women are as interested in science experiences as young men up until age nine. After that age, the number of young women interested in science, mathematics, and technology classes drops. Not enrolling in science and mathematics classes in high schoolmore » limits career options for young women, and their chance to succeed in a scientific or technical field becomes remote. Why is this happening? What can we, as educators, scientists, and parents do to address this problem? The literature identifies three principal factors that relate to the lack of female involvement in science classes: culture, attitude, and education. This paper reviews these factors and provides examples of programs that Pacific Northwest Laboratory (PNL) and others have developed to increase the number of young women entering college ready and wanting to pursue a career in a scientific or technical field.« less
Effects of angiopoietin-1 on inflammatory injury in endothelial progenitor cells and blood vessels.
Wang, Yi-Qing; Song, Jing-Jin; Han, Xiao; Liu, Yi-Ye; Wang, Xi-Huang; Li, Zhi-Ming; Tzeng, Chi-Meng
2014-01-01
Endothelial progenitor cells (EPCs) and angiopoietin-1 (Ang-1) play important roles in vasculogenesis and angiogenesis, respectively. Thus, targeting both aspects of cardiovascular tissue regeneration may offer promising therapeutic options for cardiovascular disorders. To this end, we constructed a lentiviral vector (pNL) with the Ang-1 gene and transfected EPCs with it (Ang-1-EPCs) to investigate vasculogenesis in both cellular and animal models. Compared to controls, intercellular adhesion molecule 1 (ICAM-1) and vascular cell adhesion molecule 1 (VCAM-1) increased significantly in both untreated EPCs and in the pNL vector group. After Ang-1 transcription, ICAM-1 and VCAM-1 decreased considerably in those treatment groups. Ang-1-modified EPCs alleviated inflammatory responses induced by tumor-necrosis factor-α (TNF-α) in vitro. Moreover, Ang-1-EPC implantation inhibited neointimal hyperplasia after balloon catheter injury in rats, dramatically diminishing the intimal-media (I/M) ratio and decreasing the neointimal area. Proliferating cell nuclear antigen expression in the Ang-1-EPC group was lower than the EPC non-treatment group as well, suggesting that Ang-1-EPC improved cell survival during inflammation and promoted endothelialization in damaged blood vessels.
NASA Astrophysics Data System (ADS)
Chen, Yu; Zou, Jian; Yang, Zi-Yi; Li, Longwu; Li, Hai; Shao, Bin
2016-08-01
The dynamics of N-qubit GHZ state quantum Fisher information (QFI) under phase noise lasers (PNLs) driving is investigated in terms of non-Markovian master equation. We first investigate the non-Markovian dynamics of the QFI of N-qubit GHZ state and show that when the ratio of the PNL rate and the system-environment coupling strength is very small, the oscillations of the QFIs decay slower which corresponds to the non-Markovian region; yet when it becomes large, the QFIs monotonously decay which corresponds to the Markovian region. When the atom number N increases, QFIs in both regions decay faster. We further find that the QFI flow disappears suddenly followed by a sudden birth depending on the ratio of the PNL rate and the system-environment coupling strength and the atom number N, which unveil a fundamental connection between the non-Markovian behaviors and the parameters of system-environment couplings. We discuss two optimal positive operator-valued measures (POVMs) for two different strategies of our model and find the condition of the optimal measurement. At last, we consider the QFI of two atoms with qubit-qubit interaction under random telegraph noises (RTNs).
Duncan, Ann E; Smedley, Rebecca; Anthony, Simon; Garner, Michael M
2014-09-01
Malignant melanomas are aggressive neoplasms that are relatively common in penguins compared to other avian species. In this study, the clinical and pathologic characteristics of melanocytic neoplasms in five macaroni (Eudyptes chrysolophus), three rock hopper (Eudyptes chrysocome), and two Humboldt (Spheniscus humboldti) penguins are described. Tumors most commonly occurred in the skin of the foot or hock, and were seen in the subcutaneous muscle, especially near the beak/oral cavity. Gross lesions were usually heavily pigmented, becoming raised and ulcerated over time. Humboldt penguins had a unique presentation, forming variably pigmented, cornified lesions in the inguinal area. Original case materials were obtained from all but two cases, and were assessed to define the characteristics of malignancy, evaluate four immunohistochemical markers for melanoma, and look for factors useful to informing prognosis and clinical decisions. Diagnosis was made histologically, based on morphologic features and pigmentation. Though not necessary for diagnosis, PNL-2 was found to be a useful immunohistochemical marker. HMB-45 showed unreliable positive labelling and S-100, Melan-A and Ki67 were not useful. Several factors were associated with prognosis, including gross surface dimension, mitotic index, depth of neoplastic cell invasion, and degree of surface ulceration. Metastatic spread occurred to the liver, lung, adrenal gland, brain, and bone; all lesions showed positive labelling to PNL-2. The average survival after diagnosis was 7 mo, though complete surgical excision of tumors less than 2.0 cm was curative in two cases and radiation therapy prolonged survival in one penguin. The underlying pathogenesis associated with the high prevalence of melanocytic neoplasms in captive penguins could not be identified. Three different molecular methods were performed to look for viral particles and results were negative. Advanced age is the most probable associated risk factor; ultraviolet light and chlorine exposure, viral induction, and genetic predisposition were ruled out or considered unlikely.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matzke, Brett D.; Wilson, John E.; Hathaway, J.
2008-02-12
Statistically defensible methods are presented for developing geophysical detector sampling plans and analyzing data for munitions response sites where unexploded ordnance (UXO) may exist. Detection methods for identifying areas of elevated anomaly density from background density are shown. Additionally, methods are described which aid in the choice of transect pattern and spacing to assure with degree of confidence that a target area (TA) of specific size, shape, and anomaly density will be identified using the detection methods. Methods for evaluating the sensitivity of designs to variation in certain parameters are also discussed. Methods presented have been incorporated into the Visualmore » Sample Plan (VSP) software (free at http://dqo.pnl.gov/vsp) and demonstrated at multiple sites in the United States. Application examples from actual transect designs and surveys from the previous two years are demonstrated.« less
Selection of a computer code for Hanford low-level waste engineered-system performance assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGrail, B.P.; Mahoney, L.A.
Planned performance assessments for the proposed disposal of low-level waste (LLW) glass produced from remediation of wastes stored in underground tanks at Hanford, Washington will require calculations of radionuclide release rates from the subsurface disposal facility. These calculations will be done with the aid of computer codes. Currently available computer codes were ranked in terms of the feature sets implemented in the code that match a set of physical, chemical, numerical, and functional capabilities needed to assess release rates from the engineered system. The needed capabilities were identified from an analysis of the important physical and chemical process expected tomore » affect LLW glass corrosion and the mobility of radionuclides. The highest ranked computer code was found to be the ARES-CT code developed at PNL for the US Department of Energy for evaluation of and land disposal sites.« less
Joint Institute for Nanoscience Annual Report 2003
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baer, Donald R.; Campbell, Charles
2004-02-01
The Joint Institute for Nanoscience (JIN) is a cooperative venture of the University of Washington and Pacific Northwest National Laboratory to encourage and enhance high-impact and high-quality nanoscience and nanotechnology of all types. This first annual report for the JIN summarizes activities beginning in 2001 and ending at the close of fiscal year 2003 and therefore represents somewhat less than two years of activities. Major portions of the JIN resources are dedicated to funding graduate students and postdoctoral research associates to perform research in collaborations jointly directed by Pacific Northwest National Laboratory (PNNL) staff scientists and University of Washington (UW)more » professors. These fellowships were awarded on the basis of applications that included research proposals. JIN co-sponsors an annual Nanoscale Science and Technology Workshop held in Seattle. In addition to involving PNNL staff in various UW nanoscience courses and seminars, a National Science Foundation grant Development of UW-PNL Collaborative Curriculums in Nano-Science and Technology has allowed the development of three intensive short courses that are taught by UW faculty, PNNL staff, and faculty from other institutions, including Washington State University, the University of Idaho, Stanford University, and the University of Alaska. The initial JIN agreement recognized that expansion of cooperation beyond UW and PNNL would be highly valuable. Starting in early 2003, efforts were initiated to form a regional communication link called the Northwest Nanoscience and Nanotechnology Network (N₄). In concept, N₄ is a tool to encourage communication and help identify regional resources and nanoscience and technology activities.« less
International nuclear fuel cycle fact book. Revision 6
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harmon, K.M.; Lakey, L.T.; Leigh, I.W.
1986-01-01
The International Fuel Cycle Fact Book has been compiled in an effort to provide (1) an overview of worldwide nuclear power and fuel cycle programs and (2) current data concerning fuel cycle and waste management facilities, R and D programs and key personnel. Additional information on each country's program is available in the International Source Book: Nuclear Fuel Cycle Research and Development, PNL-2478, Rev. 2.
Supersonic Transport Noise Reduction Technology Program - Phase 2. Volume 1
1975-09-01
transport aircraft . In addition, PNL and EPNL con- tributions made by each major engine component ( jet , turbine , combustor and compressor) were... Turbine noise was studied using a J85 engine with massive Inlet suppressor and open nozzle to unmask the turbine . Second-stage turbine blade /nozzle...17. Kty Words (Suggnted by Author(tl) Jet Noise, High Velocity Suppression, Aircraft Engine Suppression, Turbomachlnery Noise, Hybrid Inlet
Modeling forest C and N allocation responses to free-air CO2 enrichment
NASA Astrophysics Data System (ADS)
Luus, Kristina; De Kauwe, Martin; Walker, Anthony; Werner, Christian; Iversen, Colleen; McCarthy, Heather; Medlyn, Belinda; Norby, Richard; Oren, Ram; Zak, Donald; Zaehle, Sönke
2015-04-01
Vegetation allocation patterns and soil-vegetation partitioning of C and N are predicted to change in response to rising atmospheric concentrations of CO2. These allocation responses to rising CO2 have been examined at the ecosystem level through through free-air CO2 enrichment (FACE) experiments, and their global implications for the timing of progressive N limitation (PNL) and C sequestration have been predicted for ~100 years using a variety of ecosystem models. However, recent FACE model-data syntheses studies [1,2,3] have indicated that ecosystem models do not capture the 5-10 year site-level ecosystem allocation responses to elevated CO2. This may be due in part to the missing representation of the rhizosphere interactions between plants and soil biota in models. Ecosystem allocation of C and N is altered by interactions between soil and vegetation through the priming effect: as plant N availability diminishes, plants respond physiologically by altering their tissue allocation strategies so as to increase rates of root growth and rhizodeposition. In response, either soil organic material begins to accumulate, which hastens the onset of PNL, or soil microbes start to decompose C more rapidly, resulting in increased N availability for plant uptake, which delays PNL. In this study, a straightforward approach for representing rhizosphere interactions in ecosystem models was developed through which C and N allocation to roots and rhizodeposition responds dynamically to elevated CO2 conditions, modifying soil decomposition rates without pre-specification of the direction in which soil C and N accumulation should shift in response to elevated CO2. This approach was implemented in a variety of ecosystem models ranging from stand (G'DAY), to land surface (CLM 4.5, O-CN), to dynamic global vegetation (LPJ-GUESS) models. Comparisons against data from three forest FACE sites (Duke, Oak Ridge & Rhinelander) indicated that representing rhizosphere interactions allowed models to more reliably capture responses of ecosystem C and N allocation to free-air CO2 enrichment because they were able to simulate the priming effect. Insights were therefore gained into between-site differences observed in forest FACE experiments, and the underlying physiological and biogeochemical mechanisms determining ecosystem C and N allocation responses to elevated CO2. References 1. De Kauwe, M. G., et al. (2014), Where does the carbon go? A model-data intercomparison of vegetation carbon allocation and turnover processes at two temperate forest free-air CO2 enrichment sites, New Phytologist, 203, 883-899. 2. Walker, A. P., et al. (2014), Comprehensive ecosystem model-data synthesis using multiple data sets at two temperate forest free-air CO2 enrichment experiments: Model performance at ambient CO2 concentration, Journal of Geophysical Research: Biogeosciences, 119, 937-964. 3. Zaehle, S., et al. (2014), Evaluation of 11 terrestrial carbon-nitrogen cycle models against observations from two temperate Free-Air CO2 Enrichment studies, New Phytologist, 202 (3), 803-822.
ONR Tidal Flats DRI: Planning Joint Modeling and Field Exercises
2007-01-01
ONR Tidal Flats DRI: Planning Joint Modeling and Field Exercises Lyle Hibler Battelle/Marine Research Operations 1529 West Sequim Bay Road...West Sequim Bay Road Sequim , WA 98382 Phone: (360) 681-4591 Fax: (360) 681-4598 Email: adam.maxwell@pnl.gov Award Number: N000140710694...PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Battelle/Marine Research Operations,1529 West Sequim Bay Road, Sequim ,WA,98382 8. PERFORMING ORGANIZATION
Critical Infrastructure: Control Systems and the Terrorist Threat
2004-01-20
Congressional Research Service ˜ The Library of Congress CRS Report for Congress Received through the CRS Web Order Code RL31534 Critical...http://www.pnl.gov/main/sectors/homeland.html]. 68 Rolf Carlson, “Sandia SCADA Program High-Security SCADA LDRD Final Report ,” Sandia Report SAND2002...and Industry Division Report Documentation Page Form ApprovedOMB No. 0704-0188 Public reporting burden for the collection of information is estimated to
Critical Infrastructure: Control Systems and the Terrorist Threat
2003-07-14
Congressional Research Service ˜ The Library of Congress CRS Report for Congress Received through the CRS Web Order Code RL31534 Critical...available online at [http://www.pnl.gov/main/sectors/homeland.html]. 56 Rolf Carlson, “Sandia SCADA Program High-Security SCADA LDRD Final Report ...Industry Division Report Documentation Page Form ApprovedOMB No. 0704-0188 Public reporting burden for the collection of information is estimated to
Tagging RDT&E. Volume 1. Technology Assessment and Development Reports
1994-03-01
weapon system component could have a unique, counterfeit and transfer resistant, and tamper indicating identifier (or tag), inspectors could...the random nature of the reflective surfaces on each particle, the tag is highly resistant to counterfeiting . Sym t, n- BDM Jnvolvement RPT Sandia...layers) that tampering has occurred. A reflective particle (RP) disk was added by PNL to increase the difficulty of counterfeiting the tag and to make
Hydrogen speciation in hydrated layers on nuclear waste glass
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aines, R.D.; Weed, H.C.; Bates, J.K.
1987-12-31
The hydration of an outer layer on nuclear waste glasses in known to occur during leaching, but the actual speciation of hydrogen (as water or hydroxyl groups) in these layers has not been determined. As part of the Nevada Nuclear Waste Storage Investigations Project, we have used infrared spectroscopy to determine hydrogen speciations in three nuclear waste glass compositions (SRL-131 & 165, and PNL 76-68), which were leached at 90{sup 0}C (all glasses) or hydrated in a vapor-saturated atmosphere at 202{sup 0}C (SRL-131 only). Hydroxyl groups were found in the surface layers of all the glasses. In addition, molecular watermore » was found in the surface of SRL-131 and PNL 76-68 glasses that had been leached for several months in deionized water, and in the vapor-hydrated sample. The water/hydroxyl ratio increases with increasing reaction time; molecular water makes up most of the hydrogen in the thick reaction layers on vapor-phase hydrated glass while only hydroxyl occurs in the least reacted samples. The hydrated layer on the nuclear waste glasses appears to be of relatively low water content (4 to 7% by weight) and is not substantially hydroxylated. Thus, these layers do not have many of the properties associated with gel layers.« less
Microfasciculation: a morphological pattern in leprosy nerve damage.
Antunes, Sérgio L G; Medeiros, Mildred F; Corte-Real, Suzana; Jardim, Márcia R; Nery, José A da Costa; Hacker, Mariana A V B; Valentim, Vânia da Costa; Amadeu, Thaís Porto; Sarno, Euzenir N
2011-01-01
To study Microfasciculation, a perineurial response found in neuropathies, emphasizing its frequency, detailed morphological characteristics and biological significance in pure neural leprosy (PNL), post-treatment leprosy neuropathy (PTLN) and non-leprosy neuropathies (NLN). Morphological characteristics of microfascicles were examined via histological staining methods, immunohistochemical expression of neural markers and transmission electronmicroscopy. The detection of microfasciculation in 18 nerve biopsy specimens [12 PNL, six PTLN but not in the NLN group, was associated strongly with perineurial damage and the presence of a multibacillary inflammatory process in the nerves, particularly in the perineurium. Immunoreactivity to anti-S100 protein, anti-neurofilament, anti-nerve growth receptor and anti-myelin basic protein immunoreactivity was found within microfascicles. Ultrastructural examination of three biopsies showed that fibroblast-perineurial cells were devoid of basement membrane despite perineurial-like NGFr immunoreactivity. Morphological evidence demonstrated that multipotent pericytes from inflammation-activated microvessels could be the origin of fibroblast-perineurial cells. A microfasciculation pattern was found in 10% of leprosy-affected nerves. The microfascicles were composed predominantly of unmyelinated fibres and denervated Schwann cells (SCs) surrounded by fibroblast-perineurial cells. This pattern was found more frequently in leprosy nerves with acid-fast bacilli (AFB) and perineurial damage while undergoing an inflammatory process. Further experimental studies are necessary to elucidate microfascicle formation. © 2011 Blackwell Publishing Limited.
NASA Technical Reports Server (NTRS)
Powell, C. A.; Mccurdy, D. A.
1978-01-01
Fifty-two airplane noise recordings, made at several locations around Dulles International Airport, were analyzed to compare the low-frequency noise levels of the Concorde supersonic transport with those of other commercial jet airplanes. Comparisons of the relative low-frequency noise levels which were produced at close and distant locations for departures and arrivals were made for three noise measures: the sound pressure level in the 1/3 octave band centered at 20 Hz, the total sound pressure level in the 1/3 octave bands with center frequencies less than or equal to 125 Hz, and the total sound pressure level in the 1/3 octave bands with center frequencies less than or equal to 500 Hz. Although the absolute noise levels for Concorde were found, in general, to be higher than those for the other airplane types, the level of low-frequency noise of the Concorde relative to the perceived noise level (PNL), effective perceived noise level (EPNL), and overall sound pressure level (OASPL) was within the range established by the other airplane types, except for the arrival operations of four-engine, narrow-body airplanes. The measure OASPL was found to be a significantly better predictor of low-frequency noise level than PNL or EPNL.
Takazawa, Ryoji; Kitayama, Sachi; Tsujii, Toshihiko
2015-01-01
Flexible ureteroscopy (fURS) has become a more effective and safer treatment for whole upper urinary tract stones. Percutaneous nephrolithotomy (PNL) is currently the first-line recommended treatment for large kidney stones ≥ 20 mm and it has an excellent stone-free rate for large kidney stones. However, its invasiveness is not negligible considering its major complication rates. Staged fURS is a practical treatment for such large kidney stones because fURS has a minimal blood transfusion risk, short hospitalization and few restrictions on daily routines. However, as the stone size becomes larger, the stone-free rate decreases, and the number of operations required increases. Therefore, in our opinion, staged fURS is a practical option for kidney stones 20 to 40 mm. Miniaturized PNL combined with fURS should be considered to be a preferred option for stones larger than 40 mm. Moreover, URS is an effective treatment for multiple upper urinary tract stones. Especially for patients with a stone burden < 20 mm, URS is a favorable option that promises a high stone-free rate after a single session either unilaterally or bilaterally. However, for patients with a stone burden ≥ 20 mm, a staged operation should be considered to achieve stone-free status. PMID:25664253
Imlach, Wendy L.; Bhola, Rebecca F.; Mohammadi, Sarasa A.; Christie, Macdonald J.
2016-01-01
The development of neuropathic pain involves persistent changes in signalling within pain pathways. Reduced inhibitory signalling in the spinal cord following nerve-injury has been used to explain sensory signs of neuropathic pain but specific circuits that lose inhibitory input have not been identified. This study shows a specific population of spinal cord interneurons, radial neurons, lose glycinergic inhibitory input in a rat partial sciatic nerve ligation (PNL) model of neuropathic pain. Radial neurons are excitatory neurons located in lamina II of the dorsal horn, and are readily identified by their morphology. The amplitude of electrically-evoked glycinergic inhibitory post-synaptic currents (eIPSCs) was greatly reduced in radial neurons following nerve-injury associated with increased paired-pulse ratio. There was also a reduction in frequency of spontaneous IPSCs (sIPSCs) and miniature IPSCs (mIPSC) in radial neurons without significantly affecting mIPSC amplitude. A subtype selective receptor antagonist and western blots established reversion to expression of the immature glycine receptor subunit GlyRα2 in radial neurons after PNL, consistent with slowed decay times of IPSCs. This study has important implications as it identifies a glycinergic synaptic connection in a specific population of dorsal horn neurons where loss of inhibitory signalling may contribute to signs of neuropathic pain. PMID:27841371
Noise Reduction with Lobed Mixers: Nozzle-Length and Free-Jet Speed Effects
NASA Technical Reports Server (NTRS)
Mengle, Vinod G.; Dalton, William N.; Bridges, James C.; Boyd, Kathy C.
1997-01-01
Acoustic test results are presented for 1/4th-scaled nozzles with internal lobed mixers used for reduction of subsonic jet noise of turbofan engines with bypass ratio above 5 and jet speeds up to 830 ft/s. One coaxial and three forced lobe mixers were tested with variations in lobe penetration, cut-outs in lobe-sidewall, lobe number and nozzle-length. Measured exit flow profiles and thrusts are used to assist the inferences from acoustic data. It is observed that lobed mixers reduce the low-frequency noise due to more uniformly mixed exit flow; but they may also increase the high-frequency noise at peak perceived noise (PNL) angle and angles upstream of it due to enhanced mixing inside the nozzle. Cut-outs and low lobe penetration reduce the annoying portion of the spectrum but lead to less uniform exit flow. Due to the dominance of internal duct noise in unscalloped, high-penetration mixers their noise is not reduced as much with increase in free-jet speed as that of coaxial or cut-out lobed mixers. The latter two mixers also show no change in PNL over the wide range of nozzle-lengths tested because most of their noise sources are outside the nozzle; whereas, the former show an increase in noise with decrease in nozzle-length.
Jiang, Yan-Ling; Bai, Wen-Wei; Qu, Fan-Wei; Ma, Hua; Jiang, Run-Sheng; Shen, Bao-Sheng
2016-03-01
This study aimed to investigate the biological characterization of HIV type 1 (HIV-1) CRF07_BC infection among men who have sex with men (MSM). From November 2011 to November 2013, a total of 66 blood samples were collected from MSM with acute HIV-1 infection with CRF07_BC subgroup strains. Deletion in the gag p6 region was detected by sequence alignment and comparative analysis. Peripheral blood mononuclear cells (PBMCs) of HNXX1301-1307 samples were separated by density gradient centrifugation. Nested polymerase chain reaction (nPCR) was used to amplify the viral DNA. The near full-length HIV-1 DNA products were ligated to the long terminal repeat (LTR) vector plasmid (07BCLTR) to construct a full-length HIV clone. The molecular clone was transfected into HEK-293T cells, TZM-b1 cells and patients' PBMCs. The pregenome of an infectious molecular clone of HIV-1 (pNL4-3) was amplified, and a subclone with CRF07_BC was developed to construct the full-length chimeric molecular clone pNL4-3/07BCLTR. Detection of p24 antigen and luciferase activity was used to measure the in vitro infectivity of pNL4-3/07BCLTR. Among the 66 MSM patients infected with CRF07_BC strains, deletion mutations of the Gag P6 proteins were found in 7 of 18CRF07_BC strains; deletion mutations of 2-13 amino acids in different regions were discovered in 6 strains; and the remaining 42 strains did not show deletions. Seven strains with amino acids deficiency in the P6 protein accounted for 27% of all strains and 75% of all deletion genotype strains. A total of 186 full-length molecular clones of CRF07_BC were constructed. There were 5, 9, 10 and 11 clones of HNXX1302, HNXX1304, HNXX1305 and HNXX1306 that resulted in p24-positive supernatant when transfected into HEK-293T cells. Full-length clones of HNXX1302, HNXX1304, HNXX1305 and HNXX1306 showed slight infection in the transfected TZM-b1 cells, as judged by the fluorescence values of TZM-b1 cells 48h post-transfection. However, we were unable to transfect the patients' PMBCs with the above four clones. The phylogenetic tree of the C2V3 segment of the Env gene showed that a significant gene cluster was formed by all of the chimeric full-length HNXX1306 clones, and the bootstrap value for this cluster was 97.5%. Patients' PBMCs could be infected by 1306N6, 1306N13 and 1306N22 chimeric full-length clones. The CRF07_BC subtype (6889-7407 nucleotide residues of HXB2) is one of the most prevalent epidemic HIV-1 virus strains among the MSM population. The full-length chimeric molecular clone pNL4-3/07BCLTR may significantly improve the in vitro infectivity of the CRF07_BC strain. Copyright © 2016 Elsevier B.V. All rights reserved.
Simulation of diurnal thermal energy storage systems: Preliminary results
NASA Astrophysics Data System (ADS)
Katipamula, S.; Somasundaram, S.; Williams, H. R.
1994-12-01
This report describes the results of a simulation of thermal energy storage (TES) integrated with a simple-cycle gas turbine cogeneration system. Integrating TES with cogeneration can serve the electrical and thermal loads independently while firing all fuel in the gas turbine. The detailed engineering and economic feasibility of diurnal TES systems integrated with cogeneration systems has been described in two previous PNL reports. The objective of this study was to lay the ground work for optimization of the TES system designs using a simulation tool called TRNSYS (TRaNsient SYstem Simulation). TRNSYS is a transient simulation program with a sequential-modular structure developed at the Solar Energy Laboratory, University of Wisconsin-Madison. The two TES systems selected for the base-case simulations were: (1) a one-tank storage model to represent the oil/rock TES system; and (2) a two-tank storage model to represent the molten nitrate salt TES system. Results of the study clearly indicate that an engineering optimization of the TES system using TRNSYS is possible. The one-tank stratified oil/rock storage model described here is a good starting point for parametric studies of a TES system. Further developments to the TRNSYS library of available models (economizer, evaporator, gas turbine, etc.) are recommended so that the phase-change processes is accurately treated.
Variable thickness transient ground-water flow model. Volume 3. Program listings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reisenauer, A.E.
1979-12-01
The Assessment of Effectiveness of Geologic Isolation Systems (AEGIS) Program is developing and applying the methodology for assessing the far-field, long-term post-closure safety of deep geologic nuclear waste repositories. AEGIS is being performed by Pacific Northwest Laboratory (PNL) under contract with the Office of Nuclear Waste Isolation (OWNI) for the Department of Energy (DOE). One task within AEGIS is the development of methodology for analysis of the consequences (water pathway) from loss of repository containment as defined by various release scenarios. Analysis of the long-term, far-field consequences of release scenarios requires the application of numerical codes which simulate the hydrologicmore » systems, model the transport of released radionuclides through the hydrologic systems to the biosphere, and, where applicable, assess the radiological dose to humans. Hydrologic and transport models are available at several levels of complexity or sophistication. Model selection and use are determined by the quantity and quality of input data. Model development under AEGIS and related programs provides three levels of hydrologic models, two levels of transport models, and one level of dose models (with several separate models). This is the third of 3 volumes of the description of the VTT (Variable Thickness Transient) Groundwater Hydrologic Model - second level (intermediate complexity) two-dimensional saturated groundwater flow.« less
NASA Astrophysics Data System (ADS)
Premono, B. S.; Tjahjana, D. D. D. P.; Hadi, S.
2017-01-01
The aims of this paper are to investigate the characteristic of the wind speed and wind energy potential in the northern coastal region of Semarang, Central Java, Indonesia. The wind data was gained from Meteorological Station of Semarang, with ten-min average time series wind data for one year period, at the height of 10 m. Weibull distribution has been used to determine the wind power density and wind energy density of the site. It was shown that the value of the two parameters, shape parameter k, and scale parameter c, were 3.37 and 5.61 m/s, respectively. The annual mean wind speed and wind speed carrying the maximum energy were 5.32 m/s and 6.45 m/s, respectively. Further, the annual energy density at the site was found at a value of 103.87 W/m2, and based on Pacific North-west Laboratory (PNL) wind power classification, at the height of 10 m, the value of annual energy density is classified into class 2. The commercial wind turbine is chosen to simulate the wind energy potential of the site. The POLARIS P25-100 is most suitable to the site. It has the capacity factor 29.79% and can produce energy 261 MWh/year.
The potential for microtechnology applications in energy systems: Results of an experts workshop
NASA Astrophysics Data System (ADS)
1995-02-01
Microscale technologies, or microelectromechanical systems (MEMS), are currently under development in the United States and abroad. Examples include microsensors, microactuators (including micromotors), and microscale heat exchangers. Typically, microscale devices have features ranging in size from a few microns to several millimeters, with fabrication methods adapted from those developed for the semiconductor industry. Microtechnologies are already being commercialized; initial markets include the biomedical and transportation industries. Applications are being developed in other industries as well. Researchers at the Pacific Northwest Laboratory (PNL) hypothesize that a significant number of energy applications are possible. These applications range from environmental sensors that support enhanced control of building (or room) temperature and ventilation to microscale heat pumps and microscale heat engines that could collectively provide for kilowatt quantities of energy conversion. If efficient versions of these devices are developed, they could significantly advance the commercialization of distributed energy conversion systems, thereby reducing the energy losses associated with energy distribution. Based upon the potential for energy savings, the U.S. Department of Energy (DOE) Office of Building Technologies (OBT) has proposed a new initiative in energy systems miniaturization. The program would focus on the development of microtechnologies for the manufactured housing sector and would begin in either FY 1997 or FY 1998, ramping up to $5 million per year investment by FY 2001.
Dry deposition of large, airborne particles onto a surrogate surface
NASA Astrophysics Data System (ADS)
Kim, Eugene; Kalman, David; Larson, Timothy
Simultaneous measurements of particle dry deposition flux and airborne number concentration in the open atmosphere were made using three different types of artificially generated particles in the size range 10-100 μm - perlite, diatomaceous earth and glass beads. A combination of gravimetric analysis, automated microscopy and sonic anemometry provided size-resolved estimates of both the inertial and gravitational components of the quasi-laminar layer particle deposition velocity, ( Vd) b, as a function of size. Eddy inertial deposition efficiency ( ηdI) was determined as a function of dimensionless eddy Stokes number (Stk e). In the range 3
Expected benefits of federally-funded thermal energy storage research
NASA Astrophysics Data System (ADS)
Spanner, G. E.; Daellenbach, K. K.; Hughes, K. R.; Brown, D. R.; Drost, M. K.
1992-09-01
Pacific Northwest Laboratory (PNL) conducted this study for the Office of Advanced Utility Concepts of the US Department of Energy (DOE). The objective of this study was to develop a series of graphs that depict the long-term benefits of continuing DOE's thermal energy storage (TES) research program in four sectors: building heating, building cooling, utility power production, and transportation. The study was conducted in three steps. The first step was to assess the maximum possible benefits technically achievable in each sector. In some sectors, the maximum benefit was determined by a 'supply side' limitation, and in other sectors, the maximum benefit is determined by a 'demand side' limitation. The second step was to apply economic cost and diffusion models to estimate the benefits that are likely to be achieved by TES under two scenarios: (1) with continuing DOE funding of TES research; and (2) without continued funding. The models all cover the 20-year period from 1990 to 2010. The third step was to prepare graphs that show the maximum technical benefits achievable, the estimated benefits with TES research funding, and the estimated benefits in the absence of TES research funding. The benefits of federally-funded TES research are largely in four areas: displacement of primary energy, displacement of oil and natural gas, reduction in peak electric loads, and emissions reductions.
Interactive Rapid Dose Assessment Model (IRDAM): reactor-accident assessment methods. Vol. 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poeton, R.W.; Moeller, M.P.; Laughlin, G.J.
1983-05-01
As part of the continuing emphasis on emergency preparedness, the US Nuclear Regulatory Commission (NRC) sponsored the development of a rapid dose assessment system by Pacific Northwest Laboratory (PNL). This system, the Interactive Rapid Dose Assessment Model (IRDAM) is a micro-computer based program for rapidly assessing the radiological impact of accidents at nuclear power plants. This document describes the technical bases for IRDAM including methods, models and assumptions used in calculations. IRDAM calculates whole body (5-cm depth) and infant thyroid doses at six fixed downwind distances between 500 and 20,000 meters. Radionuclides considered primarily consist of noble gases and radioiodines.more » In order to provide a rapid assessment capability consistent with the capacity of the Osborne-1 computer, certain simplifying approximations and assumptions are made. These are described, along with default values (assumptions used in the absence of specific input) in the text of this document. Two companion volumes to this one provide additional information on IRDAM. The user's Guide (NUREG/CR-3012, Volume 1) describes the setup and operation of equipment necessary to run IRDAM. Scenarios for Comparing Dose Assessment Models (NUREG/CR-3012, Volume 3) provides the results of calculations made by IRDAM and other models for specific accident scenarios.« less
Characterization of Pseudomonas putida Genes Responsive to Nutrient Limitation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Syn, Chris K.; Magnuson, Jon K.; Kingsley, Mark T.
2004-06-01
The low bioavailability of nutrients and oxygen in the soil environment has hampered successful expression of biodegradation/biocontrol genes that are driven by promoters highly active during routine laboratory conditions of high nutrient- and oxygen-availability. Hence, in the present study, expression of the gus-tagged genes in 12 Tn5-gus mutants of the soil microbe Pseudomonas putida PNL-MK25 was examined under various conditions chosen to mimic the soil environment: low carbon, phosphate, nitrate, or oxygen, and in the rhizosphere. Based on their expression profiles, three nutrient-responsive mutant (NRM) strains, NRM5, NRM7, and NRM17, were selected for identification of the tagged genes. In themore » mutant strain NRM5, expression of the glutamate dehydrogenase (gdhA) gene was increased between 4.9- to 26.4-fold under various low nutrient conditions. In NRM7, expression of the novel NADPH:quinone oxidoreductase-like (nql) gene was consistently amongst the highest and was synergistically upregulated by low nutrient and anoxic conditions. The cyoD gene in NRM17, which encodes the fourth subunit of the cytochrome o ubiquinol oxidase complex, had decreased expression in low nutrient conditions but its absolute expression levels was still amongst the highest. Additionally, it was independent of oxygen availability, in contrast to that in E. coli.« less
Recommendations for NRC policy on shift scheduling and overtime at nuclear power plants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lewis, P.M.
1985-07-01
This report contains the Pacific Northwest Laboratory's (PNL's) recommendations to the US Nuclear Regulatory Commission (NRC) for an NRC policy on shift scheduling and hours of work (including overtime) for control room operators and other safety-related personnel in nuclear power plants. First, it is recommended that NRC make three additions to its present policy on overtime: (1) limit personnel to 112 hours of work in a 14-day period, 192 hours in 28 days, and 2260 hours in one year; exceeding these limits would require plant manager approval; (2) add a requirement that licensees obtain approval from NRC if plant personnelmore » are expected to exceed 72 hours of work in a 7-day period, 132 hours in 14 days, 228 hours in 28 days, and 2300 hours in one year; and (3) make the policy a requirement, rather than a nonbinding recommendation. Second, it is recommended that licensees be required to obtain NRC approval to adopt a routine 12-hour/day shift schedule. Third, it is recommended that NRC add several nonbinding recommendations concerning routine 8-hour/day schedules. Finally, because additional data can strengthen the basis for future NRC policy on overtime, five methods are suggested for collecting data on overtime and its effects. 44 refs., 10 tabs.« less
Cadmium Replacements for High Strength Steel Fasteners
2005-03-01
w/o corr expos – strippability (MIL-S-5002D) [fstnr & pnl] • bend test after coating reapplication • stress durability (ISO 15330) @ 96 hr before...Immersion Paint Adhesion -----45 washersGalvanic Bi-Metallic Corrosion Strippability Stress Durability Fatigue COF Torque Tension Breakaway Torque Paint...Patrick Doyle (NAWCADLKE) • Selected Issues – Zn vs Cad as control – Grade 8 (150 ksi) vs 180 ksi or 220 ksi fasteners – Use of dry film lubricants
NASA Astrophysics Data System (ADS)
Zachara, J. M.
2009-12-01
The Hanford Integrated Field Research Challenge (IFRC) site is a DOE/BER-supported experimental and monitoring facility focused on multi-scale mass transfer processes (hanfordifc@pnl.gov). It is located within the footprint of a historic uranium (U) waste disposal pond that overlies a contaminated vadose zone and a 1 km+ groundwater U plume. The plume is under a regulatory clean-up mandate. The site is in hydraulic connectivity with the Columbia River that is located approximately 300 m distant. Dramatic seasonal variations in Columbia River stage cause 2m+ variations in water table and associated changes in groundwater flow directions and composition that are believed to recharge contaminant U to the plume through lower vadose zone pumping. The 60 m triangular shaped facility contains 37 monitoring wells equipped with down-hole electrical resistance tomography electrode and thermistor arrays, pressure transducers for continual water level monitoring, and specific conductance electrodes. Well spacings allow cross-hole geophysical interrogation and dynamic plume monitoring. Various geophysical and hydrologic field characterizations were performed during and after well installation, and retrieved sediments are being subjected to a hierarchal laboratory characterization process to support geostatistical models of hydrologic properties, U(VI) distribution and speciation, and equilibrium and kinetic reaction parameters for robust but tractable field-scale reactive transport calculations. Three large scale (10,000 gal+), non-reactive tracer experiments have been performed to evaluate groundwater flowpaths and velocities, facies scale mass transfer, and subsurface heterogeneity effects under different hydrologic conditions (e.g., flow vectors toward or away from the river). A passive monitoring experiment was completed during spring and summer of 2009 that documents spatially variable U(VI) release and plume recharge from the contaminated lower vadose zone during oscillating rising and falling water table events. A large scale injection experiment to evaluate in situ U(VI) desorption kinetics controlled by mass transfer is planned for the fall of 2009. The presentation will summarize key results from these different activities, and discuss their implications to improved plume forecasting and development of an effective groundwater remedy.
NASA Astrophysics Data System (ADS)
Konca, A. O.; Ji, C.; Helmberger, D. V.
2004-12-01
We observed the effect of the fault finiteness in the Pnl waveforms from regional distances (4° to 12° ) for the Mw6.5 San Simeon Earthquake on 22 December 2003. We aimed to include more of the high frequencies (2 seconds and longer periods) than the studies that use regional data for focal solutions (5 to 8 seconds and longer periods). We calculated 1-D synthetic seismograms for the Pn_l portion for both a point source, and a finite fault solution. The comparison of the point source and finite fault waveforms with data show that the first several seconds of the point source synthetics have considerably higher amplitude than the data, while finite fault does not have a similar problem. This can be explained by reversely polarized depth phases overlapping with the P waves from the later portion of the fault, and causing smaller amplitudes for the beginning portion of the seismogram. This is clearly a finite fault phenomenon; therefore, can not be explained by point source calculations. Moreover, the point source synthetics, which are calculated with a focal solution from a long period regional inversion, are overestimating the amplitude by three to four times relative to the data amplitude, while finite fault waveforms have the similar amplitudes to the data. Hence, a moment estimation based only on the point source solution of the regional data could have been wrong by half of magnitude. We have also calculated the shifts of synthetics relative to data to fit the seismograms. Our results reveal that the paths from Central California to the south are faster than to the paths to the east and north. The P wave arrival to the TUC station in Arizona is 4 seconds earlier than the predicted Southern California model, while most stations to the east are delayed around 1 second. The observed higher uppermost mantle velocities to the south are consistent with some recent tomographic models. Synthetics generated with these models significantly improves the fits and the timing at most stations. This means that regional waveform data can be used to help locate and establish source complexities for future events.
NASA Astrophysics Data System (ADS)
Templeton, D.; Rodgers, A.; Helmberger, D.; Dreger, D.
2008-12-01
Earthquake source parameters (seismic moment, focal mechanism and depth) are now routinely reported by various institutions and network operators. These parameters are important for seismotectonic and earthquake ground motion studies as well as calibration of moment magnitude scales and model-based earthquake-explosion discrimination. Source parameters are often estimated from long-period three- component waveforms at regional distances using waveform modeling techniques with Green's functions computed for an average plane-layered models. One widely used method is waveform inversion for the full moment tensor (Dreger and Helmberger, 1993). This method (TDMT) solves for the moment tensor elements by performing a linearized inversion in the time-domain that minimizes the difference between the observed and synthetic waveforms. Errors in the seismic velocity structure inevitably arise due to either differences in the true average plane-layered structure or laterally varying structure. The TDMT method can account for errors in the velocity model by applying a single time shift at each station to the observed waveforms to best match the synthetics. Another method for estimating source parameters is the Cut-and-Paste (CAP) method. This method breaks the three-component regional waveforms into five windows: vertical and radial component Pnl; vertical and radial component Rayleigh wave; and transverse component Love waves. The CAP method performs a grid search over double-couple mechanisms and allows the synthetic waveforms for each phase (Pnl, Rayleigh and Love) to shift in time to account for errors in the Green's functions. Different filtering and weighting of the Pnl segment relative to surface wave segments enhances sensitivity to source parameters, however, some bias may be introduced. This study will compare the TDMT and CAP methods in two different regions in order to better understand the advantages and limitations of each method. Firstly, we will consider the northeastern China/Korean Peninsula region where average plane-layered structure is well known and relatively laterally homogenous. Secondly, we will consider the Middle East where crustal and upper mantle structure is laterally heterogeneous due to recent and ongoing tectonism. If time allows we will investigate the efficacy of each method for retrieving source parameters from synthetic data generated using a three-dimensional model of seismic structure of the Middle East, where phase delays are known to arise from path-dependent structure.
Management of lower pole renal stones: the devil is in the details.
Resorlu, Berkan; Issi, Yasar; Onem, Kadir; Germiyanoglu, Cankon
2016-03-01
Shock wave lithotripsy (SWL), retrograde intrarenal surgery (RIRS) and minimally invasive percutaneous nephrolithotomy (MIP) are highly effective treatment options for lower pole stones up to 2 cm. Selecting the best treatment modality represents a controversial area in urology, because each treatment methods have their own advantages and disadvantages. Donaldson and co-workers have recently published a very comprehensive review and meta-analysis to compare the benefits and harms of SWL, RIRS and PNL techniques.
Detection of Atmospheric Carbon Dioxide from a Shuttle-Borne Lidar.
1982-12-01
d, e_! *Pnl * cooling of the stratosphere. This will occur due to absorp- tion of the earth’s infrared radiation by CO2, and subse- quent emission of...and four vibrational modes. The available energy bands are a function of three vibrational quantum numbers describing the four vibrational modes: 1...insufficient to describe the energy levels based solely on three vibrational quantum numbers, and the rotational quantum number (J). Two additional .".,. 8
NASA Astrophysics Data System (ADS)
Erickson, Dennis C.; Donnelly, Matt K.
1995-04-01
The authors present a design concept describing a multifunctional data acquisition and analysis architecture for advanced power system monitoring. The system is tailored to take advantage of the salient features of low energy sensors, particularly optical types. The discussion of the system concept and optical sensors is based on research at BPA and PNL and on progress made at existing BPA installations and other sites in the western power system.
NASA Technical Reports Server (NTRS)
Strout, F. G.
1978-01-01
A JT8D-17R engine with inverted primary and fan flows was tested under static conditions as well as in the NASA Ames 40 by 80 Foot Wind Tunnel to determine static and flight noise characteristics, and flow profile of a large scale engine. Test and analysis techniques developed by a previous model and JT8D engine test program were used to determine the in-flight noise. The engine with inverted flow was tested with a conical nozzle and with a plug nozzle, 20 lobe nozzle, and an acoustic shield. Wind tunnel results show that forward velocity causes significant reduction in peak PNL suppression relative to uninverted flow. The loss of EPNL suppression is relatively modest. The in-flight peak PNL suppression of the inverter with conical nozzle was 2.5 PNdb relative to a static value of 5.5 PNdb. The corresponding EPNL suppression was 4.0 EPNdb for flight and 5.0 EPNdb for static operation. The highest in-flight EPNL suppression was 7.5 EPNdb obtained by the inverter with 20 lobe nozzle and acoustic shield. When compared with the JT8D engine with internal mixer, the inverted flow configuration provides more EPNL suppression under both static and flight conditions.
P Wave Velocity Structure Beneath the Baikal Rift Axis
NASA Astrophysics Data System (ADS)
Brazier, R. A.; Nyblade, A. A.; Boman, E. C.
2001-12-01
Over 100 p wave travel times from the 1500 km en echelon Baikal Rift system are used in this study.The events range 3 to 13 degrees from Talaya, Russia (TLY) along the axis of southwest northeast trending rift in East Siberia. A Herglotz Wiechert inversion of these events resolved a crust of 6.4 km/s and a gradient in the mantle starting at 35 km depth and 7.7 km/s down to 200 km depth and 8.2 km/s. This is compatible with Gao et al,1994 cross sectional structure which cuts the rift at about 400km from TLY. The Baikal Rift hosts the deepest lake and is the most seismically active rift in the world. It is one of the few continental rifts, it separates the Siberian craton and the Syan-Baikal mobile fold belt. Two events, the March 21 1999 magnitude 5.7 earthquake 638 km from TLY and the November 13th 1995 magnitude 5.9 earthquake 863 km from TLY were modeled for there PnL wave structure using the discrete wavenumber method and the Harvard CMT solutions with adjusted depths from p-pP times. The PnL signals match well. A genetic algorithm will used to perturb the velocity structure and compare to a selection of the events between 3 and 13 degrees many will require moment tensor solutions.
NASA Technical Reports Server (NTRS)
Groesbeck, D.; Vonglahn, U.
1979-01-01
The effects on acoustic characteristics of nozzle type and location on a wing for STOL engine over-the-wing configurations are assessed at full scale on the basis of model-scale data. Three types of nozzle configurations are evaluated: a circular nozzle with external deflector mounted above the wing, a slot nozzle with external deflector mounted on the wing and a slot nozzle mounted on the wing. Nozzle exhaust plane locations with respect to the wing leading edge are varied from 10 to 46 percent chord (flaps retracted) with flap angles of 20 (takeoff altitude) and 60 (approach attitude). Perceived noise levels (PNL) are calculated as a function of flyover distance at 152 m altitude. From these plots, static EPNL values, defined as flyover relative noise levels, are calculated and plotted as a function of lift and thrust ratios. From such plots the acoustic benefits attributable to variations in nozzle/deflector/wing geometry at full scale are assessed for equal aerodynamic performance.
High Power Microwaves (HPM) (les Micro-ondes de forte puissance (MFP).
1995-03-01
the polarization vector , [C/m 2], P1 is the polarization term which is linearly dependent on the electric field, and Pnl is The soliton laser [35...which utilizes Kerr nonlinearity in the polarization vector which is nonlinearly dependent on the optical fiber, has also been demonstrated. In the case...forward propa- then applied across the cathode. If the electric gating volume harmonics of the TMO1 mode, field is of the proper polarity , a phase tran- as
NASA Technical Reports Server (NTRS)
Kozlowski, H.; Packman, A. B.
1978-01-01
Jet noise spectra obtained at static conditions from an acoustic wind tunnel and an outdoor facility are compared. Data curves are presented for (1) the effect of relative velocity on OASPL directivity (all configurations); (2) the effect of relative velocity on noise spectra (all configurations); (3) the effect of velocity on PNL directivity (coannular nozzle configurations); (4) nozzle exhaust plume velocity profiles; and (5) the effect of relative velocity on aerodynamic performance.
Hanford Internal Dosimetry Program Manual, PNL-MA-552
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carbaugh, Eugene H.; Bihl, Donald E.; Maclellan, Jay A.
2003-10-10
This manual is a guide to the services provided by the Hanford Internal Dosimetry Program (IDP). It describes the roles of and relationships between the IDP and site contractors, and provides recommendations and guidance for consideration in implementing bioassay monitoring and internal dosimetry elements of radiation protection programs. Guidance includes identifying conditions under which workers should be placed on bioassay programs, types, descritptions, and capabilities of measurements, suggested routine bioassay programs, limitations on services, and practices for recording and reporting results.
In Vivo Monitoring Program Manual, PNL-MA-574
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lynch, Timothy P.
2010-07-01
An overview of the administration for the In Vivo Monitoring Program (IVMP) for Hanford. This includes organizational structure and program responsibilities; coordination of in vivo measurements; scheduling measurements; performing measurements; reporting results; and quality assurance. Overall responsibility for the management of the IVMP rests with the Program Manager (PM). The PM is responsible for providing the required in vivo counting services for Hanford Site contractor employees in accordance with Department of Energy (DOE) requirements and the specific statements of work.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gupta, S.K.; Cole, C.R.; Bond, F.W.
1979-12-01
The Assessment of Effectiveness of Geologic Isolation Systems (AEGIS) Program is developing and applying the methodology for assessing the far-field, long-term post-closure safety of deep geologic nuclear waste repositories. AEGIS is being performed by Pacific Northwest Laboratory (PNL) under contract with the Office of Nuclear Waste Isolation (OWNI) for the Department of Energy (DOE). One task within AEGIS is the development of methodology for analysis of the consequences (water pathway) from loss of repository containment as defined by various release scenarios. Analysis of the long-term, far-field consequences of release scenarios requires the application of numerical codes which simulate the hydrologicmore » systems, model the transport of released radionuclides through the hydrologic systems to the biosphere, and, where applicable, assess the radiological dose to humans. Hydrologic and transport models are available at several levels of complexity or sophistication. Model selection and use are determined by the quantity and quality of input data. Model development under AEGIS and related programs provides three levels of hydrologic models, two levels of transport models, and one level of dose models (with several separate models). This document consists of the description of the FE3DGW (Finite Element, Three-Dimensional Groundwater) Hydrologic model third level (high complexity) three-dimensional, finite element approach (Galerkin formulation) for saturated groundwater flow.« less
Valsangkar, Nakul P; Bush, Devon M; Michaelson, James S; Ferrone, Cristina R; Wargo, Jennifer A; Lillemoe, Keith D; Fernández-del Castillo, Carlos; Warshaw, Andrew L; Thayer, Sarah P
2013-02-01
We evaluated the prognostic accuracy of LN variables (N0/N1), numbers of positive lymph nodes (PLN), and lymph node ratio (LNR) in the context of the total number of examined lymph nodes (ELN). Patients from SEER and a single institution (MGH) were reviewed and survival analyses performed in subgroups based on numbers of ELN to calculate excess risk of death (hazard ratio, HR). In SEER and MGH, higher numbers of ELN improved the overall survival for N0 patients. The prognostic significance (N0/N1) and PLN were too variable as the importance of a single PLN depended on the total number of LN dissected. LNR consistently correlated with survival once a certain number of lymph nodes were dissected (≥13 in SEER and ≥17 in the MGH dataset). Better survival for N0 patients with increasing ELN likely represents improved staging. PLN have some predictive value but the ELN strongly influence their impact on survival, suggesting the need for a ratio-based classification. LNR strongly correlates with outcome provided that a certain number of lymph nodes is evaluated, suggesting that the prognostic accuracy of any LN variable depends on the total number of ELN.
BRIEF REPORT: A simple interpolation formula for the spectra of power-law and log potentials
NASA Astrophysics Data System (ADS)
Hall, Richard L.
2000-06-01
Non-relativistic potential models are considered of the pure power V(r) = sgn(q) r q and logarithmic V(r) = ln (r) types. It is shown that, from the spectral viewpoint, these potentials are actually in a single family. The log spectra can be obtained from the power spectra by the limit q→0 taken in a smooth representation Pnl(q) for the eigenvalues Enl(q). A simple approximation formula is developed which yields the first 30 eigenvalues with an error less than 0.04%.
1979-01-01
Characteristics - V z 1640ft/sec, ma 72 7-26. Comparison of Aerotrain and 4.0 in. Conical Nozzle OASPL Characteristics. 75 7-27. Comparison of Acrotrain and 4.0 in...Conical Nozzle PNL Characteristics. 76 ix LIST OF ILLUSTRATIONS (Continued) Figure Page 7-28. Conical Nozzle Spectra Comparisons with Aerotrain . 77 7...free jet and Aerotrain Test Series (References 6, 9, & 10) are used for com.aring all the static and flight noise results from the above scale model
NASA Technical Reports Server (NTRS)
Groesbeck, D.; Von Glahn, U.
1979-01-01
The effects on acoustic characteristics of nozzle type and location on a wing for STOL engine over-the-wing configurations are assessed at full scale on the basis of model-scale data. Three types of nozzle configurations are evaluated: a circular nozzle with external deflector mounted above the wing, a slot nozzle with external deflector mounted on the wing and a slot nozzle mounted on the wing. Nozzle exhaust plane locations with respect to the wing leading edge are varied from 10 to 46 percent chord (flaps retracted) with flap angles of 20 deg (take-off attitude) and 60 deg (approach attitude). Perceived noise levels (PNL) are calculated as a function of flyover distance at 152 m altitude. From these plots, static EPNL values, defined as flyover relative noise levels, are calculated and plotted as a function of lift and thrust ratios. From such plots the acoustic benefits attributable to variations in nozzle/deflector/wing geometry at full scale are assessed for equal aerodynamic performance.
Regional versus General Anesthesia for Percutaneous Nephrolithotomy: A Meta-Analysis
Hu, Henglong; Qin, Baolong; He, Deng; Lu, Yuchao; Zhao, Zhenyu; Zhang, Jiaqiao; Wang, Yufeng; Wang, Shaogang
2015-01-01
Objective To compare the effectiveness and safety of regional anesthesia (RA) and general anesthesia (GA) for percutaneous nephrolithotomy (PNL). Patients and Methods PubMed, EMBASE, The Cochrane Library, and the Web of Knowledge databases were systematically searched to identify relevant studies. After literature screening and data extraction, a meta-analysis was performed using the RevMan 5.3 software. Results Eight randomized controlled trials (RCTs) and six non-randomized controlled trials (nRCTs) involving 2270 patients were included. Patients receiving RA were associated with shorter operative time (−6.22 min; 95%CI, −9.70 to −2.75; p = 0.0005), lower visual analgesic score on the first and third postoperative day (WMD, −2.62; 95%CI, −3.04 to −2.19; p < 0.00001 WMD, −0.38; 95%CI, −0.58 to −0.18; p = 0.0002), less analgesic requirements (WMD, −59.40 mg; 95%CI, −78.39 to −40.40; p<0.00001), shorter hospitalization (WMD, −0.36d; 95%CI, −0.66 to −0.05; p = 0.02), less blood transfusion (RR, 0.61; 95%CI, 0.41 to 0.93; p = 0.02), fewer modified Clavion-Dindo Grade II (RR, 0.56; 95%CI, 0.37 to 0.83; p = 0.005), Grade III or above postoperative complications (RR, 0.51; 95%CI, 0.33 to 0.77; p = 0.001), and potential benefits of less fever (RR, 0.79; 95%CI, 0.61 to 1.02; p = 0.07), nausea or vomiting (RR, 0.54; 95%CI, 0.20 to 1.46; p = 0.23), whereas more intraoperative hypotension (RR, 3.13; 95%CI, 1.76 to 5.59; p = 0.0001) when compared with patients receiving GA. When nRCTs were excluded, most of the results were stable but the significant differences were no longer detectable in blood transfusion, Grade II and more severe complications. No significant difference in the total postoperative complications and stone-free rate were found. Conclusions Current evidence suggests that both RA and GA can provide safe and effective anesthesia for PNL in carefully evaluated and selected patients. Each anesthesia technique has its own advantages but some aspects still remain unclear and need to be explored in future studies. PMID:25961831
Experimental investigation of shock-cell noise reduction for dual-stream nozzles in simulated flight
NASA Technical Reports Server (NTRS)
Janardan, B. A.; Yamamoto, K.; Majjigi, R. K.; Brausch, J. F.
1984-01-01
Six scale-model nozzles were tested in an anechoic facility to evauate the effectiveness of convergent-divergent (C-D) terminations in reducing shock-cell noise of unsuppressed and mechanically suppressed coannular plug nozzles. One hundred fifty-three acoustic test points with inverted velocity profiles were conducted under static and simulated flight conditions. Diagnostic flow visualization with a shadowgraph and velocity measurements with a laser velocimeter were performed on selected plumes. Shock-cells were identified on the plug and downstream of the plug of the unsuppressed convergent coannular nozzle with truncated plug. Broadband peak frequencies predicted with the two shock-cell structures were correlated with the observed spectra using the measured shock-cell spacings. Relative to a convergent circular nozzle, the perceived noise level (PNL) data at an observer angle of 60 deg relative to inlet, indicated a reduction of (1) 6.5 dB and 9.2 dB with unsuppressed C-D coannular nozzle with truncated plug and (2) 7.7 dB and 8.3 dB with suppressed C-D coannular nozzle under static and simulated flight conditions, espectively. The unsuppressed C-D coannular nozzle with truncated plug, operating at the C-D design condition, had shock-cells downstream of the plug with no shock-cells on the plug. The downstream shock-cells were eliminated by replacing the truncated plug with a smooth extension to obtain an additional 2.4 dB and 3 dB front quadrant PNL reduction, under static and simulated flight conditions, respectively. Other results are discussed.
Joint Inversion of Earthquake Source Parameters with local and teleseismic body waves
NASA Astrophysics Data System (ADS)
Chen, W.; Ni, S.; Wang, Z.
2011-12-01
In the classical source parameter inversion algorithm of CAP (Cut and Paste method, by Zhao and Helmberger), waveform data at near distances (typically less than 500km) are partitioned into Pnl and surface waves to account for uncertainties in the crustal models and different amplitude weight of body and surface waves. The classical CAP algorithms have proven effective for resolving source parameters (focal mechanisms, depth and moment) for earthquakes well recorded on relatively dense seismic network. However for regions covered with sparse stations, it is challenging to achieve precise source parameters . In this case, a moderate earthquake of ~M6 is usually recorded on only one or two local stations with epicentral distances less than 500 km. Fortunately, an earthquake of ~M6 can be well recorded on global seismic networks. Since the ray paths for teleseismic and local body waves sample different portions of the focal sphere, combination of teleseismic and local body wave data helps constrain source parameters better. Here we present a new CAP mothod (CAPjoint), which emploits both teleseismic body waveforms (P and SH waves) and local waveforms (Pnl, Rayleigh and Love waves) to determine source parameters. For an earthquake in Nevada that is well recorded with dense local network (USArray stations), we compare the results from CAPjoint with those from the traditional CAP method involving only of local waveforms , and explore the efficiency with bootstraping statistics to prove the results derived by CAPjoint are stable and reliable. Even with one local station included in joint inversion, accuracy of source parameters such as moment and strike can be much better improved.
Resonances and thresholds in the Rydberg-level population of multiply charged ions at solid surfaces
NASA Astrophysics Data System (ADS)
Nedeljković, Lj. D.; Nedeljković, N. N.
1998-12-01
We present a theoretical study of resonances and thresholds, two specific features of Rydberg-state formation of multiply charged ions (Z=6, 7, and 8) escaping a solid surface at intermediate velocities (v~1 a.u.) in the normal emergence geometry. The resonances are recognized in pronounced maxima of the experimentally observed population curves of Ar VIII ions for resonant values of the principal quantum number n=nres=11 and for the angular momentum quantum numbers l=1 and 2. Absence of optical signals in detectors of beam-foil experiments for n>nthr of S VI and Cl VII ions (with l=0, 1, and 2) and Ar VIII for l=0 is interpreted as a threshold phenomenon. An interplay between resonance and threshold effects is established within the framework of quantum dynamics of the low angular momentum Rydberg-state formation, based on a generalization of Demkov-Ostrovskii's charge-exchange model. In the model proposed, the Ar VIII resonances appear as a consequence of electron tunneling in the very vicinity of the ion-surface potential barrier top and at some critical ion-surface distances Rc. The observed thresholds are explained by means of a decay mechanism of ionic Rydberg states formed dominantly above the Fermi level EF of a solid conduction band. The theoretically predicted resonant and threshold values, nres and nthr of the principal quantum number n, as well as the obtained population probabilities Pnl=Pnl(v,Z), are in sufficiently good agreement with all available experimental findings.
Anatrophic Nephrolithotomy in the Management of Large Staghorn Calculi - A Single Centre Experience.
Keshavamurthy, Ramaiah; Karthikeyan, Vilvapathy Senguttuvan; Mallya, Ashwin; Sreenivas, Jayaram; Nelivigi, Girish Gurubasappa; Kamath, Ananth Janarthan
2017-05-01
With advances in endourology, open stone surgery for staghorn calculi has markedly diminished. Anatrophic Nephrolithotomy (AN) is performed for complex staghorn stones which cannot be cleared by a reasonable number of Percutaneous Nephrolithotomy (PNL) attempts. To assess the indications and outcomes of AN in the modern era. Between April 2008 and July 2015, AN was done in 14 renal units in 13 patients. In this retrospective study, demography, stone characteristics, operative details, clearance and long term outcomes were assessed. AN was performed for complex staghorn calculi involving pelvis and all calyces in 10 patients, infundibular stenosis in two patients and failed PNL in one patient. Mean (SD) in situ cold ischemia time was 47.64 (5.27) minutes. Retroperitoneal drain and double J stent were placed in all 13 patients. Median (IQR) estimated blood loss was 130 (75) ml. There was no perioperative mortality. Surgical site infection was seen in 2 patients and urosepsis in 2 patients. Drain was removed at a mean (SD) of 9.11 (6.15) days. Mean (SD) postoperative length of hospitalization was 15.44 (7.14) days. Stent removal was done in all patients between 2-8 weeks. Median (IQR) clearance was 95 (7.5%). There was no renal failure or new calculi during the follow up period {median (IQR): 1(3) years}. AN is effective in management of large staghorn calculi failed minimally invasive approaches and achieves 80%-100% clearance without much need for secondary interventions. Renal function is preserved and with emergence of laparoscopy and robotics, postoperative stay is minimized with expedited recovery and comparable results with open surgery.
Users guide for ENVSTD program Version 2. 0 and LTGSTD program Version 2. 0
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crawley, D.B.; Riesen, P.K.; Briggs, R.S.
1989-02-01
On January 30, 1989, the US Department of Energy (DOE) promulgated 10 CFR Part 435, Subpart A, an Interim Rule entitled ''Energy Conservation Voluntary Performance Standards for New Commercial and Multi-Family High Rise Residential Buildings; Mandatory for New Federal Buildings.'' As a consequence, federal agencies must design all future federal commercial and multifamily high rise residential buildings in accordance with the Standards, or show that their current standards already meet or exceed the energy-efficiency requirements of the Standards. Although these newly enacted Standards do not regulate the design of nonfederal buildings, DOE recommends that all design professionals use the Standardsmore » as guidelines for designing energy-conserving buildings. To encourage private sector use, the Standards were presented in the January 30, 1989, Federal Register in the format typical of commercial standards rather than a federal regulation. As a further help, DOE supported the development of various microcomputer programs to ease the use of the Standards. Two of these programs/emdash/ENVSTD (Version 2.0) and LTGSTD (Version 2.0)/emdash/are detailed in this users guide and provided on the accompanying diskette. This package, developed by Pacific Northwest Laboratory (PNL), is intended to facilitate the designer's use of the Standards dealing specifically with a building's envelope and lighting system designs. Using these programs will greatly simplify the designer's task of performing the sometimes complex calculations needed to determine a design's compliance with the Standards. 3 refs., 6 figs.« less
Ultralight Fabric Reflux Tube (UFRT) Thermal/Vacuum Test
NASA Technical Reports Server (NTRS)
Hurlbert, K. M.; Ewert, M. K.; Graf, J. P.; Keller, J. R.; Pauley, K. A.; Guenther, R. J.; Antoniak, Z. I.
1996-01-01
Spacecraft thermal control systems are essential to provide the necessary environment for the crew and equipment to function adequately on space missions. The Ultralight Fabric Reflux Tube (UFRT) was developed by Pacific Northwest Laboratory (PNL) as a lightweight radiator concept to be used on planetary-type missions (e.g., Moon, Mars). The UFRT consists of a thin-walled tube (acting as the fluid boundary), overwrapped with a low-mass ceramic fabric (acting as the primary pressure boundary). The tubes are placed in an array in the vertical position with the evaporators at the lower end. Heat is added to the evaporators, which vaporizes the working fluid. The vapor travels to the condenser end above and cools as heat is radiated to the environment. The fluid condensed on the tube wall is then returned to the evaporator by gravity. The primary objectives for the fiscal year 1994 program included the design and fabrication of prototype UFRTs and thermal/vacuum chamber testing of these test articles. Six UFRTS, with improved titanium liners, were successfully manufactured and provided to the Johnson Space Center in July 1994. Five were tested in a thermal/vacuum chamber in September 1994. Data obtained to characterize the performance of the UFRTs under simulated lunar conditions demonstrated the design concept successfully. In addition, a trade study showed that an optimized/improved UFRT could achieve as much as a 25% mass savings in the heat rejection subsystem of future planetary-type thermal control systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Friedrichs, D.R.; Argo, R.S.
The Assessment of Effectiveness of Geologic Isolation Systems (AEGIS) Program is developing and applying the methodology for assessing the far-field, long-term post-closure safety of deep geologic nuclear waste repositories. AEGIS is being performed by Pacific Northwest Laboratory (PNL) under contract with the Office of Nuclear Waste Isolation (ONWI) for the Department of Energy (DOE). One task within AEGIS is the development of methodology for analysis of the consequences (water pathway) from loss of repository containment as defined by various release scenarios. The various input parameters required in the analysis are compiled in data systems. The data are organized and preparedmore » by various input subroutines for utilization by the hydraulic and transport codes. The hydrologic models simulate the groundwater flow systems and provide water flow directions, rates, and velocities as inputs to the transport models. Outputs from the transport models are basically graphs of radionuclide concentration in the groundwater plotted against time. After dilution in the receiving surface-water body (e.g., lake, river, bay), these data are the input source terms for the dose models, if dose assessments are required. The dose models calculate radiation dose to individuals and populations. CIRMIS (Comprehensive Information Retrieval and Model Input Sequence) Data System, a storage and retrieval system for model input and output data, including graphical interpretation and display is described. This is the third of four volumes of the description of the CIRMIS Data System.« less
Cutaneous Chromatophoromas in Captive Snakes.
Muñoz-Gutiérrez, J F; Garner, M M; Kiupel, M
2016-11-01
Chromatophoromas are neoplasms arising from pigment-bearing cells (chromatophores) of the dermis. While isolated cases have been reported in the literature, the prevalence and biological behavior of chromatophoromas in snakes are unknown. Forty-two chromatophoromas were identified among 4663 submissions (0.9%) to a private diagnostic laboratory in a 16-year period. The most commonly affected snakes were colubrids (23 cases, 55%) and vipers (8 cases, 19%). The San Francisco garter snake was the most commonly affected species (6 cases; 14% of all affected snake species and 3.7% of all garter snake submissions). No sex predilection was found. The age of 28 snakes ranged from 5 to 27 years. Single cutaneous chromatophoromas were most commonly observed and presented as pigmented cutaneous masses or plaques along any body segment. Euthanasia or death due to progressive neoplastic disease or metastasis was reported in 8 (19%) and 4 (10%) cases, respectively. The survival time of 4 animals ranged from 4 to 36 months. Microscopically, xanthophoromas, iridophoromas, melanocytic neoplasms, and mixed chromatophoromas were identified, with melanocytic neoplasms being most common. Microscopic examination alone was generally sufficient for the diagnosis of chromatophoroma, but immunohistochemistry for S-100 and PNL-2 may be helpful for diagnosing poorly pigmented cases. Moderate to marked nuclear atypia appears to be consistently present in cutaneous chromatophoromas with a high risk of metastasis, while mitotic count, lymphatic invasion, the level of infiltration, and the degree of pigmentation or ulceration were not reliable predictors of metastasis. © The Author(s) 2016.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Friedrichs, D.R.
1980-01-01
The Assessment of Effectiveness of Geologic Isolation Systems (AEGIS) Program is developing and applying the methodology for assessing the far-field, long-term post-closure safety of deep geologic nuclear waste repositories. AEGIS is being performed by Pacific Northwest Laboratory (PNL) under contract with the Office of Nuclear Waste Isolation (ONWI) for the Department of Energy (DOE). One task within AEGIS is the development of methodology for analysis of the consequences (water pathway) from loss of repository containment as defined by various release scenarios. The various input parameters required in the analysis are compiled in data systems. The data are organized and preparedmore » by various input subroutines for use by the hydrologic and transport codes. The hydrologic models simulate the groundwater flow systems and provide water flow directions, rates, and velocities as inputs to the transport models. Outputs from the transport models are basically graphs of radionuclide concentration in the groundwater plotted against time. After dilution in the receiving surface-water body (e.g., lake, river, bay), these data are the input source terms for the dose models, if dose assessments are required. The dose models calculate radiation dose to individuals and populations. CIRMIS (Comprehensive Information Retrieval and Model Input Sequence) Data System, a storage and retrieval system for model input and output data, including graphical interpretation and display is described. This is the first of four volumes of the description of the CIRMIS Data System.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carr, F. Jr.; Mahaffey, J.A.
The purpose of the DOE/OHER Chernobyl Database project is to create and maintain an information system to provide usable information for research studies related to the nuclear accident. The system is the official United States repository for information about the Chernobyl accident and its consequences, and currently includes an extensive bibliography and diverse radiological measurements with supporting information. PNL has established two resources: original (not summarized) measurement data, currently about 80,000 measurements, with ancillary information; and about 2,200 bibliographic citations, some including abstracts. Major organizations that have contributed radiological measurement data include the Washington State Department of Social and Healthmore » Services; United States Environmental Protection Agency (domestic and foreign data); United States Nuclear Regulatory Commission; Stone Webster; Brookhaven National Laboratory; Commissariat A L'energie Atomique in France; Ministry of Agriculture, Fisheries, and Food in the United Kingdom; Japan National Institute of Radiological Sciences; and the Finnish Centre For Radiation and Nuclear Safety (STUK). Scientists in Australia, Austria, Belgium, Canada, China, Denmark, England, Federal Republic of Germany, Finland, France, Ireland, Italy, Japan, the Netherlands, Romania, Scotland, Spain, Sweden, Switzerland, United States, Wales, and Yugoslavia have made contributions. Bibliographic materials have been obtained from scientists in the above countries that have replied to requests. In addition, literature searches have been conducted, including a search of the DOE Energy Database. The last search was conducted in January, 1989. This document lists the bibliographic information in the DOE/OHER Chernobyl Database at the current time.« less
Naval Undersea Warfare Center Division Newport utilities metering, Phase 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carroll, D.M.
Pacific Northwest Laboratory developed this report for the US Navy`s Naval Undersea Warfare Center Division Newport, Rhode Island (NUWC). The purpose of the report was to review options for metering electricity and steam used in the NUWC compound, and to make recommendations to NUWC for implementation under a follow-on project. An additional NUWC concern is a proposed rate change by the servicing utility, Newport Electric, which would make a significant shift from consumption to demand billing, and what effect that rate change would have on the NUWC utility budget. Automated, remote reading meters are available which would allow NUWC tomore » monitor its actual utility consumption and demand for both the entire NUWC compound and by end-use in individual buildings. Technology is available to perform the meter reads and manipulate the data using a personal computer with minimal staff requirement. This is not meant to mislead the reader into assuming that there is no requirement for routine preventive maintenance. All equipment requires routine maintenance to maintain its accuracy. While PNL reviewed the data collected during the site visit, however, it became obvious that significant opportunities exist for reducing the utility costs other than accounting for actual consumption and demand. Unit costs for both steam and electricity are unnecessarily high, and options are presented in this report for reducing them. Additionally, NUWC has an opportunity to undertake a comprehensive energy resource management program to significantly reduce its energy demand, consumption, and costs.« less
Naval Undersea Warfare Center Division Newport utilities metering, Phase 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carroll, D.M.
Pacific Northwest Laboratory developed this report for the US Navy's Naval Undersea Warfare Center Division Newport, Rhode Island (NUWC). The purpose of the report was to review options for metering electricity and steam used in the NUWC compound, and to make recommendations to NUWC for implementation under a follow-on project. An additional NUWC concern is a proposed rate change by the servicing utility, Newport Electric, which would make a significant shift from consumption to demand billing, and what effect that rate change would have on the NUWC utility budget. Automated, remote reading meters are available which would allow NUWC tomore » monitor its actual utility consumption and demand for both the entire NUWC compound and by end-use in individual buildings. Technology is available to perform the meter reads and manipulate the data using a personal computer with minimal staff requirement. This is not meant to mislead the reader into assuming that there is no requirement for routine preventive maintenance. All equipment requires routine maintenance to maintain its accuracy. While PNL reviewed the data collected during the site visit, however, it became obvious that significant opportunities exist for reducing the utility costs other than accounting for actual consumption and demand. Unit costs for both steam and electricity are unnecessarily high, and options are presented in this report for reducing them. Additionally, NUWC has an opportunity to undertake a comprehensive energy resource management program to significantly reduce its energy demand, consumption, and costs.« less
NASA Technical Reports Server (NTRS)
Larson, R. S.; Nelson, D. P.; Stevens, B. S.
1979-01-01
Five co-annular nozzle models, covering a systematic variation of nozzle geometry, were tested statically over a range of exhaust conditions including inverted velocity profile (IVP) (fan to primary stream velocity ratio 1) and non IVP profiles. Fan nozzle pressure ratio (FNPR) was varied from 1.3 to 4.1 at primary nozzle pressure ratios (PNPR) of 1.53 and 2.0. Fan stream temperatures of 700 K (1260 deg R) and 1089 K(1960 deg R) were tested with primary stream temperatures of 700 K (1260 deg R), 811 K (1460 deg R), and 1089 K (1960 deg R). At fan and primary stream velocities of 610 and 427 m/sec (2000 and 1400 ft/sec), respectively, increasing fan radius ratio from 0.69 to 0.83 reduced peak perceived noise level (PNL) 3 dB, and an increase in primary radius ratio from 0 to 0.81 (fan radius ratio constant at 0.83) reduced peak PNL an additional 1.0 dB. There were no noise reductions at a fan stream velocity of 853 m/sec (2800 ft/sec). Increasing fan radius ratio from 0.69 to 0.83 reduced nozzle thrust coefficient 1.2 to 1.5% at a PNPR of 1.53, and 1.7 to 2.0% at a PNPR of 2.0. The developed acoustic prediction procedure collapsed the existing data with standard deviation varying from + or - 8 dB to + or - 7 dB. The aerodynamic performance prediction procedure collapsed thrust coefficient measurements to within + or - .004 at a FNPR of 4.0 and a PNPR of 2.0.
Role of sentinel lymph node biopsy in oral cancer.
Calabrese, L; Bruschini, R; Ansarin, M; Giugliano, G; De Cicco, C; Ionna, F; Paganelli, G; Maffini, F; Werner, J A; Soutar, D
2006-12-01
Squamous cell carcinoma of the oral cavity represents about 2% of all malignant neoplasms and 47% of those developing in the head and neck area. The tongue is the most common site involved, and this incidence is increasing mainly in young people, possibly related to human papilloma virus infections. Prognosis depends on the stage: the 5-year survival rate of tongue squamous cell carcinoma, whatever the T stage, is 73% in pN0 cases, 40% in patients with positive nodes without extracapsular spread (pNl ECS-), and 29% when nodes are metastatic with extracapsular spread (pNl ECS+: p > or = 0.0001). Nodal micrometastases (cN0 pN1) are found in up to 50% of cN0 tongue squamous cell carcinoma patients operated on the neck. At present, no clinical, imaging staging modalities or biological markers are available to diagnose nodal micrometastases. The sentinel node biopsy has been tested since 1996 in order to find a solution to this problem. The sentinel node is the first node reached by the lymphatic stream, assuming an orderly and sequential drainage from the tumour site, and should be predictive of the nodal stage. According to the literature, sentinel node biopsy is a reliable technique in selected cN0 cases, but the procedure is still experimental and should not be performed outside validation trials. Successful application of sentinel node biopsy in the head and neck region requires surgical experience and specific technical devices, including pre-operative lymphoscintigraphy and intra-operative gamma-probe. Moreover, dynamic lymphoscintigraphy seems to be able to show the lymphatic stream from the primary tumour and could allow a selective neck dissection to be tailored thus reducing the related morbidity.
Cherry Irradiation Studies. 1984 annual report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eakin, D.E.; Hungate, F.P.; Tingey, G.L.
1985-04-01
Fresh cherries, cherry fruit fly larvae, and codling moth larvae were irradiated using the PNL cobalt-60 facility to determine the efficacy of irradiation treatment for insect disinfestation and potential shelf life extension. Irradiation is an effective disinfestation treatment with no significant degradation of fruit at doses well above those required for quarantine treatment. Sufficient codling moth control was achieved at projected doses of less than 25 krad; cherry fruit fly control, at projected doses of less than 15 krad. Dose levels up to 60 krad did not adversely affect cherry quality factors tested. Irradiation above 60 krad reduced the firmnessmore » of cherries but had no significant impact on other quality factors tested. Irradiation of cherries below 80 krad did not result in any significant differences in sensory evaluations (appearance, flavor, and firmness) in tests conducted at OSU. Irradiation up to 200 krad at a temperature of about 25/sup 0/C (77/sup 0/F) did not measurably extend shelf life. Irradiation at 500 krad at 25/sup 0/C (77/sup 0/F) increased mold and rotting of cherries tested. There is no apparent advantage of irradiation over low-temperature fumigation.« less
On the scaling of small-scale jet noise to large scale
NASA Technical Reports Server (NTRS)
Soderman, Paul T.; Allen, Christopher S.
1992-01-01
An examination was made of several published jet noise studies for the purpose of evaluating scale effects important to the simulation of jet aeroacoustics. Several studies confirmed that small conical jets, one as small as 59 mm diameter, could be used to correctly simulate the overall or perceived noise level (PNL) noise of large jets dominated by mixing noise. However, the detailed acoustic spectra of large jets are more difficult to simulate because of the lack of broad-band turbulence spectra in small jets. One study indicated that a jet Reynolds number of 5 x 10(exp 6) based on exhaust diameter enabled the generation of broad-band noise representative of large jet mixing noise. Jet suppressor aeroacoustics is even more difficult to simulate at small scale because of the small mixer nozzles with flows sensitive to Reynolds number. Likewise, one study showed incorrect ejector mixing and entrainment using a small-scale, short ejector that led to poor acoustic scaling. Conversely, fairly good results were found with a longer ejector and, in a different study, with a 32-chute suppressor nozzle. Finally, it was found that small-scale aeroacoustic resonance produced by jets impacting ground boards does not reproduce at large scale.
On the scaling of small-scale jet noise to large scale
NASA Technical Reports Server (NTRS)
Soderman, Paul T.; Allen, Christopher S.
1992-01-01
An examination was made of several published jet noise studies for the purpose of evaluating scale effects important to the simulation of jet aeroacoustics. Several studies confirmed that small conical jets, one as small as 59 mm diameter, could be used to correctly simulate the overall or PNL noise of large jets dominated by mixing noise. However, the detailed acoustic spectra of large jets are more difficult to simulate because of the lack of broad-band turbulence spectra in small jets. One study indicated that a jet Reynolds number of 5 x 10 exp 6 based on exhaust diameter enabled the generation of broad-band noise representative of large jet mixing noise. Jet suppressor aeroacoustics is even more difficult to simulate at small scale because of the small mixer nozzles with flows sensitive to Reynolds number. Likewise, one study showed incorrect ejector mixing and entrainment using small-scale, short ejector that led to poor acoustic scaling. Conversely, fairly good results were found with a longer ejector and, in a different study, with a 32-chute suppressor nozzle. Finally, it was found that small-scale aeroacoustic resonance produced by jets impacting ground boards does not reproduce at large scale.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tolić, Nikola; Liu, Yina; Liyu, Andrey
Ultrahigh-resolution mass spectrometry, such as Fourier transform ion-cyclotron resonance mass spectrometry (FT-ICR MS), can resolve thousands of molecular ions in complex organic matrices. A Compound Identification Algorithm (CIA) was previously developed for automated elemental formula assignment for natural organic matter (NOM). In this work we describe a user friendly interface for CIA, titled Formularity, which includes an additional functionality to perform search of formulas based on an Isotopic Pattern Algorithm (IPA). While CIA assigns elemental formulas for compounds containing C, H, O, N, S, and P, IPA is capable of assigning formulas for compounds containing other elements. We used halogenatedmore » organic compounds (HOC), a chemical class that is ubiquitous in nature as well as anthropogenic systems, as an example to demonstrate the capability of Formularity with IPA. A HOC standard mix was used to evaluate the identification confidence of IPA. The HOC spike in NOM and tap water were used to assess HOC identification in natural and anthropogenic matrices. Strategies for reconciliation of CIA and IPA assignments are discussed. Software and sample databases with documentation are freely available from the PNNL OMICS software repository https://omics.pnl.gov/software/formularity.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rodland, Karin D.; Bollinger, Nikki; Ippolito, Danielle L.
2008-11-14
REVIEW ENTIRE DOCUMENT AT: https://pnlweb.pnl.gov/projects/bsd/ERICA%20Manuscripts%20for%20Review/KD%20Rodland%20D7E80/HMEC_transactivation_ms01_15+Figs.pdf ABSTRACT: Using a single nontransformed strain of human mammary epithelial cells, we found that the ability of multiple growth factors and cytokines to induce ERK phosphorylation was dependent on EGFR activity. These included lysophosphatidic acid (LPA), uridine triphosphate, growth hormone, vascular endothelial growth factor, insulin-like growth factor-1 (IGF-1), and tumor necrosis factoralpha. In contrast, hepatocyte growth factor could stimulate ERK phosphorylation independent of EGFR activity...
Analysis of magnesium XI line profiles from solar active regions
NASA Technical Reports Server (NTRS)
Blake, R. L.; Cowan, R. D.; Felthauser, H.; Fenimore, E. E.; Hockaday, M. P.; Bely-Dubau, F.; Faucher, P.; Steenman-Clark, L.
1984-01-01
High-resolution solar spectra of the Mg XI 1s2 1S0-1s2p 1P1 resonance line at 9.169 A and the associated nearby satellite lines obtained from two rocket-borne crystal spectrometer measurements are presented. Comparisons with two independent sets of theoretical calculations for the 1s2nl-1s2pnl dielectronic satellite lines with n = 3-7 indicate electron temperatures of 4-4.5 million K. Measured line widths indicate either that the ion temperature exceeds the electron temperature by about a million K or that about 28 km/s of turbulence is present.
Noise Levels and Data Correction Analysis for Seven General Aviation Propeller Aircraft.
1980-09-01
31-1 60 M, NORTH THRESHOLD RNWY. 13 DATE: JUNE 19,1978 EVENT EPNL DBA(M) DBD (M) OASPL PNL(M) PNLT(M) DUR(P) TC AEPNL * I APPROACH 2 87.2 78.7 85.6...DOT/TSC 10/18/78 SUMMARY NOISE LEVEL. DATA AS MEASURED * SITE NO. 31-2 2000 M. NORTH THRESHOLD RNWY. 13 DATE: JUNE 19,1978 EVENT EPNL DBA(M) DBD (M...DOT/TSC 11/13/78 SUMMARY NOISE LEVEL DATA AS MEASURED SITE NO, 31-3 3485 M, NORTH THRESHOLD RNWY. 13 DATE: JUNE 19P1978 EVENT EPNL DBA(M) DBD (M) OASPL
Analysis of High-Throughput ELISA Microarray Data
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, Amanda M.; Daly, Don S.; Zangar, Richard C.
Our research group develops analytical methods and software for the high-throughput analysis of quantitative enzyme-linked immunosorbent assay (ELISA) microarrays. ELISA microarrays differ from DNA microarrays in several fundamental aspects and most algorithms for analysis of DNA microarray data are not applicable to ELISA microarrays. In this review, we provide an overview of the steps involved in ELISA microarray data analysis and how the statistically sound algorithms we have developed provide an integrated software suite to address the needs of each data-processing step. The algorithms discussed are available in a set of open-source software tools (http://www.pnl.gov/statistics/ProMAT).
Pressure-temperature dependence of nanowire formation in the arsenic-sulfur system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riley, Brian J.; Johnson, Bradley R.; Sundaram, S. K.
2006-12-01
Nanowire Formation in Arsenic Trisulfide Brian J. Riley, S.K. Sundaram*, Bradley R. Johnson, Mark Engelhard Pacific Northwest National Laboratory, PO Box 999, Richland, WA 99352 * Corresponding author: Phone: 509-373-6665; Fax: 509-376-3108, E-mail: sk.Sundaram@pnl.gov Abstract: Arsenic trisulfide (As2S3) nanowires, nano-droplets, and micro-islands were synthesized on fused silica substrates, using a sublimation-condensation process at reduced pressures (70 mtorr – 70 torr) in a sealed ampoule. Microstructural control of the deposited thin film was achieved by controlling initial pressure, substrate temperature and substrate surface treatment. Microstructures were characterized using scanning electron microscopy (SEM), and energy dispersive spectrometry (EDS). Surface topography and chemistrymore » of the substrates were characterized using x-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM). Semi-quantitative image analysis and basic curve-fitting were used to develop empirical models to mathematically describe the variation of microstructure as a function of initial pressure and substrate temperature and map out the regions of different microstructures in P-T space. Thermodyamic properties (available from literature) of this system are also incorporated in this map. Nanowires of an amorphous, transparent in visible-LWIR region, semi-conducting material, like As2S3, provide new opportunities for the development of novel nano-photonic and electronic devices. Additionally, this system provides an excellent opportunity to model (and control) microstructure development from nanometer to micron scales in a physical vapor deposition process, which is of great value to nanoscience and nanotechnology in general.« less
A Method for Estimating Noise from Full-Scale Distributed Exhaust Nozzles
NASA Technical Reports Server (NTRS)
Kinzie, Kevin W.; Schein, David B.
2004-01-01
A method to estimate the full-scale noise suppression from a scale model distributed exhaust nozzle (DEN) is presented. For a conventional scale model exhaust nozzle, Strouhal number scaling using a scale factor related to the nozzle exit area is typically applied that shifts model scale frequency in proportion to the geometric scale factor. However, model scale DEN designs have two inherent length scales. One is associated with the mini-nozzles, whose size do not change in going from model scale to full scale. The other is associated with the overall nozzle exit area which is much smaller than full size. Consequently, lower frequency energy that is generated by the coalesced jet plume should scale to lower frequency, but higher frequency energy generated by individual mini-jets does not shift frequency. In addition, jet-jet acoustic shielding by the array of mini-nozzles is a significant noise reduction effect that may change with DEN model size. A technique has been developed to scale laboratory model spectral data based on the premise that high and low frequency content must be treated differently during the scaling process. The model-scale distributed exhaust spectra are divided into low and high frequency regions that are then adjusted to full scale separately based on different physics-based scaling laws. The regions are then recombined to create an estimate of the full-scale acoustic spectra. These spectra can then be converted to perceived noise levels (PNL). The paper presents the details of this methodology and provides an example of the estimated noise suppression by a distributed exhaust nozzle compared to a round conic nozzle.
Microbeam studies of the sensitivity of structures within living cells
NASA Technical Reports Server (NTRS)
Braby, L. A.
1992-01-01
Determining the biological effects of low doses of radiation with high linear energy transfer (LET) is complicated by the stochastic nature of charged-particle interactions. Populations of cells exposed to very low radiation doses contain a few cells which have been hit by a charged particle, while the majority of the cells receive no radiation damage. At somewhat higher doses, a few cells receive two or more events. Because the effects of damage produced by separate events can interact in the cell, we have had to make assumptions about the nature of these interactions in order to interpret the results of the experiments. Many of those assumptions can be tested if we can be sure of the number of charged-particle events which occur in individual cells, and correlate this number with the biological effect. We have developed a special irradiation facility at Pacific Northwest Laboratory (PNL) to control the actual number of charged particle tracks that pass through cell nuclei. The beam from a 2 MeV tandem accelerator is collimated to approximately 5 microns. Cells, grown in special dishes with 1.5 microns thick plastic bottoms, are positioned so that the desired portion of the cell aligns with the collimator. A shutter in the beam line is opened and closed after the desired number of particle tracks has been counted. This approach can be used to investigate the effects of the interaction between irradiated and unirradiated cells in an organized system, as well as to study the effects of spatial and temporal distribution of radiation damage within single cells.(ABSTRACT TRUNCATED AT 250 WORDS).
Long, H. Keith; Daddow, Richard L.; Farrar, Jerry W.
1998-01-01
Since 1962, the U.S. Geological Survey (USGS) has operated the Standard Reference Sample Project to evaluate the performance of USGS, cooperator, and contractor analytical laboratories that analyze chemical constituents of environmental samples. The laboratories are evaluated by using performance evaluation samples, called Standard Reference Samples (SRSs). SRSs are submitted to laboratories semi-annually for round-robin laboratory performance comparison purposes. Currently, approximately 100 laboratories are evaluated for their analytical performance on six SRSs for inorganic and nutrient constituents. As part of the SRS Project, a surplus of homogeneous, stable SRSs is maintained for purchase by USGS offices and participating laboratories for use in continuing quality-assurance and quality-control activities. Statistical evaluation of the laboratories results provides information to compare the analytical performance of the laboratories and to determine possible analytical deficiences and problems. SRS results also provide information on the bias and variability of different analytical methods used in the SRS analyses.
Local Directed Percolation Probability in Two Dimensions
NASA Astrophysics Data System (ADS)
Inui, Norio; Konno, Norio; Komatsu, Genichi; Kameoka, Koichi
1998-01-01
Using the series expansion method and Monte Carlo simulation,we study the directed percolation probability on the square lattice Vn0=\\{ (x,y) \\in {Z}2:x+y=even, 0 ≤ y ≤ n, - y ≤ x ≤ y \\}.We calculate the local percolationprobability Pnl defined as the connection probability between theorigin and a site (0,n). The critical behavior of P∞lis clearly different from the global percolation probability P∞g characterized by a critical exponent βg.An analysis based on the Padé approximants shows βl=2βg.In addition, we find that the series expansion of P2nl can be expressed as a function of Png.
The effects of vector leptoquark on the ℬb(ℬ = Λ,Σ) →ℬμ+μ- decays
NASA Astrophysics Data System (ADS)
Wang, Shuai-Wei; Huang, Jin-Shu
2016-07-01
In this paper, we have studied the baryonic semileptonic ℬb(ℬ = Λ, Σ) →ℬμ+μ- decays in the vector leptoquark model with U = (3, 3, 2/3) state. Using the parameters’ space constrained through some well-measured decay modes, such as Bs → μ+μ-, Bs -B¯s mixing and B → K∗μ+μ- decays, we show the effects of vector leptoquark state on the double lepton polarization asymmetries of ℬb(ℬ = Λ, Σ) →ℬμ+μ- decays, and find that the double lepton polarization asymmetries, except for PLL, PLN and PNL, are sensitive to the contributions of vector leptoquark model.
Program Derivation by Proof Transformation
1993-10-01
variable name. InfA (rA)I-[ #e1 (A, el F vF 0’ P) 4. e2 [node(x, v) :: u/gA XsINDTS [u o v/ lA f [] = ei (1,A )F P1 P2 f(node(x’,V)::U) u’)[ 0fl/A [node(z...iforalle 1 (foralle n (md ( En ) iforall El ] implies (eq n (tisize 1)) (A 1)) (iforalli E1] impliesi [q: I- (eq zero (tisize 1)) (leq-.subst..o ( El ] A 1) (P...nl 1 q) Base-.case)) ( En [p’: I- (iforall El ] implies (eq n (tisize 1) (A 1)) (iforalli El ) iinpliesi Eq: I- (eq (succ n) (tisize 1)) (existse (Ex
Towards an evaluation framework for Laboratory Information Systems.
Yusof, Maryati M; Arifin, Azila
Laboratory testing and reporting are error-prone and redundant due to repeated, unnecessary requests and delayed or missed reactions to laboratory reports. Occurring errors may negatively affect the patient treatment process and clinical decision making. Evaluation on laboratory testing and Laboratory Information System (LIS) may explain the root cause to improve the testing process and enhance LIS in supporting the process. This paper discusses a new evaluation framework for LIS that encompasses the laboratory testing cycle and the socio-technical part of LIS. Literature review on discourses, dimensions and evaluation methods of laboratory testing and LIS. A critical appraisal of the Total Testing Process (TTP) and the human, organization, technology-fit factors (HOT-fit) evaluation frameworks was undertaken in order to identify error incident, its contributing factors and preventive action pertinent to laboratory testing process and LIS. A new evaluation framework for LIS using a comprehensive and socio-technical approach is outlined. Positive relationship between laboratory and clinical staff resulted in a smooth laboratory testing process, reduced errors and increased process efficiency whilst effective use of LIS streamlined the testing processes. The TTP-LIS framework could serve as an assessment as well as a problem-solving tool for the laboratory testing process and system. Copyright © 2016 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.
Evaluation of Calibration Laboratories Performance
NASA Astrophysics Data System (ADS)
Filipe, Eduarda
2011-12-01
One of the main goals of interlaboratory comparisons (ILCs) is the evaluation of the laboratories performance for the routine calibrations they perform for the clients. In the frame of Accreditation of Laboratories, the national accreditation boards (NABs) in collaboration with the national metrology institutes (NMIs) organize the ILCs needed to comply with the requirements of the international accreditation organizations. In order that an ILC is a reliable tool for a laboratory to validate its best measurement capability (BMC), it is needed that the NMI (reference laboratory) provides a better traveling standard—in terms of accuracy class or uncertainty—than the laboratories BMCs. Although this is the general situation, there are cases where the NABs ask the NMIs to evaluate the performance of the accredited laboratories when calibrating industrial measuring instruments. The aim of this article is to discuss the existing approaches for the evaluation of ILCs and propose a basis for the validation of the laboratories measurement capabilities. An example is drafted with the evaluation of the results of mercury-in-glass thermometers ILC with 12 participant laboratories.
Electron capture into large-l Rydberg states of multiply charged ions escaping from solid surfaces
NASA Astrophysics Data System (ADS)
Nedeljković, N.; Nedeljković, Lj.; Mirković, M.
2003-07-01
We have investigated the electron capture into large-l Rydberg states of multiply charged ionic projectiles (e.g., the core charges Z=6, 7, and 8) escaping solid surfaces with intermediate velocities (v≈1 a.u.) in the normal emergence geometry. A model of the nonresonant electron capture from the solid conduction band into the moving large angular-momentum Rydberg states of the ions is developed through a generalization of our results obtained previously for the low-l cases (l=0, 1, and 2). The model is based on the two-wave-function dynamics of the Demkov-Ostrovskii type. The electron exchange process is described by a mixed flux through a moving plane (“Firsov plane”), placed between the solid surface and the ionic projectile. Due to low eccentricities of the large-l Rydberg systems, the mixed flux must be evaluated through the whole Firsov plane. It is for this purpose that a suitable asymptotic method is developed. For intermediate ionic velocities and for all relevant values of the principal quantum number n≈Z, the population probability Pnl is obtained as a nonlinear l distribution. The theoretical predictions concerning the ions S VI, Cl VII, and Ar VIII are compared with the available results of the beam-foil experiments.
Hydrogen speciation in hydrated layers on nuclear waste glass
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aines, R.D.; Weed, H.C.; Bates, J.K.
1987-01-15
The hydration of an outer layer on nuclear waste glasses is known to occur during leaching, but the actual speciation of hydrogen (as water or hydroxyl groups) in these layers has not been determined. As part of the Nevada Nuclear Waste Storage Investigations Project, we have used infrared spectroscopy to determine hydrogen speciations in three nuclear waste glass compositions (SRL-131 & 165, and PNL 76-68), which were leached at 90{sup 0}C (all glasses) or hydrated in a vapor-saturated atmosphere at 202{sup 0}C (SRL-131 only). Hydroxyl groups were found in the surface layers of all the glasses. Molecular water was foundmore » in the surface of SRL-131 and PNL 76-68 glasses that had been leached for several months in deionized water, and in the vapor-hydrated sample. The water/hydroxyl ratio increases with increasing reaction time; molecular water makes up most of the hydrogen in the thick reaction layers on vapor-phase hydrated glass while only hydroxyl occurs in the least reacted samples. Using the known molar absorptivities of water and hydroxyl in silica-rich glass the vapor-phase layer contained 4.8 moles/liter of molecular water, and 0.6 moles water in the form hydroxyl. A 15 {mu}m layer on SRL-131 glass formed by leaching at 90{sup 0}C contained a total of 4.9 moles/liter of water, 2/3 of which was as hydroxyl. The unreacted bulk glass contains about 0.018 moles/liter water, all as hydroxyl. The amount of hydrogen added to the SRL-131 glass was about 70% of the original Na + Li content, not the 300% that would result from alkali=hydronium ion interdiffusion. If all the hydrogen is then assumed to be added as the result of alkali-H{sup +} interdiffusion, the molecular water observed may have formed from condensation of the original hydroxyl groups.« less
When routine D-J implantation necessary during PNL?
Bayrak, Omer; Seckiner, Ilker; Erturhan, Sakip M; Bulut, Ersan; Demirbag, Asaf; Erbagci, Asaf
2015-03-01
We investigated the characteristics of patients who underwent Double-J catheter (D-J) implantation, the risk factors for prolonged urine leakage (PUL), and prediction of patients who require medical treatment. The data of 535 adult patients who underwent PNL due to kidney stone disease between January 2005 and December 2011 in our clinic were analyzed retrospectively. Patients were divided into 2 groups: Group 1 (n=77) (14.39%) included patients with Double-J catheter due to prolonged (> 24 h) urinary leakage and Group 2 (n=458) (85.61%) patients without urinary leakage. The mean stone burden was 951.94 ± 539.09 mm2 in Group 1, and 676.35 ±296.65 mm2 in Group 2 (p<0.05). DJ catheter was implanted in 11.33% of the patients with stone burden below 1000 mm2 versus in 51.21% of the patients with stone burden above 1000 mm2. In Group 1, the number of patients with two or more accesses performed was 18.18, whereas in Group 2 it was 8.5% (p<0.05). Among all patients, DJ implantation was performed in 13.07% of patients with a single access versus 26.41% of patients with two or more accesses. Also, DJ catheter was implanted in 41.46%of patients with residual stones versus 12.14% of stone-free patients. Three patients with stone burden above 1000 mm2, two or more accesses, and residual stone, all of them required DJ implantation. DJ implantation due to PUL had approximately 5-fold increase stone burden above 1000 mm2, 2-fold increase in patients undergoing two or more access and 3-fold increase in patients with residual stones. Therefore, we think that the D-J implantation is highly advisable in case of a stone load above 1000 mm2, two or more accesses, and in patients with residual stones.
ADVANCED WAVEFORM SIMULATION FOR SEISMIC MONITORING EVENTS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Helmberger, Donald V.; Tromp, Jeroen; Rodgers, Arthur J.
The recent Nevada Earthquake (M=6) produced an extraordinary set of crustal guided waves. In this study, we examine the three-component data at all the USArray stations in terms of how well existing models perform in predicting the various phases, Rayleigh waves, Love waves, and Pnl waves. To establish the source parameters, we applied the Cut and Paste Code up to distance of 5° for an average local crustal model which produced a normal mechanism (strike=35°,dip=41°,rake=-85°) at a depth of 9 km and Mw=5.9. Assuming this mechanism, we generated synthetics at all distances for a number of 1D and 3D models.more » The Pnl observations fit the synthetics for the simple models well both in timing (VPn=7.9km/s) and waveform fits out to a distance of about 5°. Beyond this distance a great deal of complexity can be seen to the northwest apparently caused by shallow subducted slab material. These paths require considerable crustal thinning and higher P-velocities. Small delays and advances outline the various tectonic province to the south, Colorado Plateau, etc. with velocities compatible with that reported on by Song et al.(1996). Five-second Rayleigh waves (Airy Phase) can be observed throughout the whole array and show a great deal of variation ( up to 30s). In general, the Love waves are better behaved than the Rayleigh waves. We are presently adding higher frequency to the source description by including source complexity. Preliminary inversions suggest rupture to northeast with a shallow asperity. We are, also, inverting the aftershocks to extend the frequencies to 2 Hz and beyond following the calibration method outlined in Tan and Helmberger (2007). This will allow accurate directivity measurements for events with magnitude larger than 3.5. Thus, we will address the energy decay with distance as s function of frequency band for the various source types.« less
CIRMIS Data system. Volume 2. Program listings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Friedrichs, D.R.
1980-01-01
The Assessment of Effectiveness of Geologic Isolation Systems (AEGIS) Program is developing and applying the methodology for assessing the far-field, long-term post-closure safety of deep geologic nuclear waste repositories. AEGIS is being performed by Pacific Northwest Laboratory (PNL) under contract with the Office of Nuclear Waste Isolation (OWNI) for the Department of Energy (DOE). One task within AEGIS is the development of methodology for analysis of the consequences (water pathway) from loss of repository containment as defined by various release scenarios. Analysis of the long-term, far-field consequences of release scenarios requires the application of numerical codes which simulate the hydrologicmore » systems, model the transport of released radionuclides through the hydrologic systems, model the transport of released radionuclides through the hydrologic systems to the biosphere, and, where applicable, assess the radiological dose to humans. The various input parameters required in the analysis are compiled in data systems. The data are organized and prepared by various input subroutines for utilization by the hydraulic and transport codes. The hydrologic models simulate the groundwater flow systems and provide water flow directions, rates, and velocities as inputs to the transport models. Outputs from the transport models are basically graphs of radionuclide concentration in the groundwater plotted against time. After dilution in the receiving surface-water body (e.g., lake, river, bay), these data are the input source terms for the dose models, if dose assessments are required.The dose models calculate radiation dose to individuals and populations. CIRMIS (Comprehensive Information Retrieval and Model Input Sequence) Data System is a storage and retrieval system for model input and output data, including graphical interpretation and display. This is the second of four volumes of the description of the CIRMIS Data System.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Friedrichs, D.R.
1980-01-01
The Assessment of Effectiveness of Geologic Isolation Systems (AEGIS) Program is developing and applying the methodology for assessing the far-field, long-term post-closure safety of deep geologic nuclear waste repositories. AEGIS is being performed by Pacific Northwest Laboratory (PNL) under contract with the Office of Nuclear Waste Isolation (ONWI) for the Department of Energy (DOE). One task within AEGIS is the development of methodology for analysis of the consequences (water pathway) from loss of repository containment as defined by various release scenarios. Analysis of the long-term, far-field consequences of release scenarios requires the application of numerical codes which simulate the hydrologicmore » systems, model the transport of released radionuclides through the hydrologic systems to the biosphere, and, where applicable, assess the radiological dose to humans. The various input parameters required in the analysis are compiled in data systems. The data are organized and prepared by various input subroutines for use by the hydrologic and transport codes. The hydrologic models simulate the groundwater flow systems and provide water flow directions, rates, and velocities as inputs to the transport models. Outputs from the transport models are basically graphs of radionuclide concentration in the groundwater plotted against time. After dilution in the receiving surface-water body (e.g., lake, river, bay), these data are the input source terms for the dose models, if dose assessments are required. The dose models calculate radiation dose to individuals and populations. CIRMIS (Comprehensive Information Retrieval and Model Input Sequence) Data System is a storage and retrieval system for model input and output data, including graphical interpretation and display. This is the fourth of four volumes of the description of the CIRMIS Data System.« less
System safety management lessons learned from the US Army acquisition process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piatt, J.A.
1989-05-01
The Assistant Secretary of the Army for Research, Development and Acquisition directed the Army Safety Center to provide an audit of the causes of accidents and safety of use restrictions on recently fielded systems by tracking residual hazards back through the acquisition process. The objective was to develop lessons learned'' that could be applied to the acquisition process to minimize mishaps in fielded systems. System safety management lessons learned are defined as Army practices or policies, derived from past successes and failures, that are expected to be effective in eliminating or reducing specific systemic causes of residual hazards. They aremore » broadly applicable and supportive of the Army structure and acquisition objectives. Pacific Northwest Laboratory (PNL) was given the task of conducting an independent, objective appraisal of the Army's system safety program in the context of the Army materiel acquisition process by focusing on four fielded systems which are products of that process. These systems included the Apache helicopter, the Bradley Fighting Vehicle (BFV), the Tube Launched, Optically Tracked, Wire Guided (TOW) Missile and the High Mobility Multipurpose Wheeled Vehicle (HMMWV). The objective of this study was to develop system safety management lessons learned associated with the acquisition process. The first step was to identify residual hazards associated with the selected systems. Since it was impossible to track all residual hazards through the acquisition process, certain well-known, high visibility hazards were selected for detailed tracking. These residual hazards illustrate a variety of systemic problems. Systemic or process causes were identified for each residual hazard and analyzed to determine why they exist. System safety management lessons learned were developed to address related systemic causal factors. 29 refs., 5 figs.« less
An analytic solution for periodic thermally-driven flows over an infinite slope
NASA Astrophysics Data System (ADS)
Zardi, Dino; Serafin, Stefano
2013-04-01
The flow generated along an infinite slope in an unperturbed stably stratified atmosphere at rest by a time periodic surface temperature forcing is examined. Following Defant (1949), a set of equations is derived which extends Prandtl's (1942) theory to allow for nonstationary conditions. Uniform boundary conditions are conducive to an along-slope parallel flow, governed by a periodically reversing local imbalance between along-slope advection and slope-normal fluxes of momentum and heat. Solutions include both a transient part and a subsequent periodic regime. The former can only be expressed in an integral form, whereas the latter is a combination of exponential and sine or cosine functions of time and height normal to the slope. Key parameters are the quantity Nα = N sinα (where α is the slope angle, and N is the Brunt-Väisälä frequency of the unperturbed atmosphere) and the angular frequency of the driving surface temperature cycle, ?. Three different flow regimes may occur, namely subcritical (Nα < ?), critical (Nα = ?) and supercritical (Nα > ?). The properties of the solutions in each regime are examined and discussed. The relationship between the present solutions and the earlier time-dependent slope flow model by Defant (1949) is also discussed. References Defant, F., 1949: Zur Theorie der Hangwinde, nebst Bemerkungen zur Theorie der Berg- und Talwinde. [A theory of slope winds, along with remarks on the theory of mountain winds and valley winds]. Arch. Meteor. Geophys. Bioclimatol., Ser. A, 1, 421-450 (Theoretical and Applied Climatology). [English translation: Whiteman, C.D., and E. Dreiseitl, 1984: Alpine meteorology: Translations of classic contributions by A. Wagner, E. Ekhart and F. Defant. PNL-5141 / ASCOT-84-3. Pacific Northwest Laboratory, Richland, Washington, 121 pp]. Prandtl, L., 1942: Strömungslehre [Flow Studies]. Vieweg und Sohn, Braunschweig, 382 pp.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lohrasbi, J.
Dose calculations for atmospheric radionuclide releases from the Hanford Site for calendar year (CY) 1992 were performed by Pacific Northwest Laboratory (PNL) using the approved US Environmental Protection Agency (EPA) CAP-88 computer model. Emissions from discharge points in the Hanford Site 100, 200, 300, 400, and 600 areas were calculated based on results of analyses of continuous and periodic sampling conducted at the discharge points. These calculated emissions were provided for inclusion in the CAP-88 model by area and by individual facility for those facilities having the potential to contribute more than 10 percent of the Hanford Site total ormore » to result in an impact of greater than 0.1 mrem per year to the maximally exposed individual (MEI). Also included in the assessment of offsite dose modeling are the measured radioactive emissions from all Hanford Site stacks that have routine monitoring performed. Record sampling systems have been installed on all stacks and vents that use exhaust fans to discharge air that potentially may carry airborne radioactivity. Estimation of activity from ingrowth of long-lived radioactive progeny is not included in the CAP-88 model; therefore, the Hanford Site GENII code (Napier et al. 1988) was used to supplement the CAP-88 dose calculations. When the dose to the MEI located in the Ringold area was calculated, the effective dose equivalent (EDE) from combined Hanford Site radioactive airborne emissions was shown to be 3.7E-03 mrem. This value was reported in the annual air emission report prepared for the Hanford Site (RL 1993).« less
Matala, E; Hahn, T; Yedavalli, V R; Ahmad, N
2001-12-10
Our previous study has shown that the human immunodeficiency virus type 1 (HIV-1) envelope V3 region minor genotypes of infected mothers were transmitted to their infants and predominated initially as a homogeneous virus population in the infants (Ahmad N, Baroudy BM, Baker RC, et al.: J Virol 1995;69:1001-1012). Here we have characterized the biological properties, including cellular tropism, replication efficiency, cytopathic effects, and coreceptor utilization, of these V3 region isolates from mothers and infants. Nineteen V3 region sequences from three mother-infant pairs, including the minor variants of mothers and the major variants of infants as characterized in our previous study, were reciprocally inserted into an HIV-1 infectious molecular clone, pNL4-3, and chimeric viruses were generated by DNA transfections into HeLa cells. Equal amounts of chimeric viruses were then used to infect T lymphocyte cell lines (A3.01 and MT-2), primary blood lymphocytes (PBLs), primary monocyte-derived macrophages (MDMs), and coreceptor cell lines. We found that the V3 region chimeras failed to replicate in T lymphocyte cell lines but replicated in MDMs and PBLs, albeit at reduced levels compared with R5 laboratory HIV-1 strains. In addition, the V3 region chimeras were able to infect the HOS-CD4(+)CCR5(+) cell line, suggesting CCR5 coreceptor utilization. Moreover, the V3 region chimeras were unable to induce syncytia in MT-2 cells, indicative of non-syncytium-inducing (NSI) phenotypes. In conclusion, the HIV-1 minor genotypes of infected mothers with macrophage-tropic and NSI or R5 phenotypes are transmitted to their infants and are initially maintained with the same properties.
Men'shikov, V V
2013-08-01
The external evaluation of quality of clinical laboratory examinations was gradually introduced in USSR medical laboratories since 1970s. In Russia, in the middle of 1990 a unified all-national system of external evaluation quality was organized known as the Federal center of external evaluation of quality at the basis of laboratory of the state research center of preventive medicine. The main positions of policy in this area were neatly formulated in the guidance documents of ministry of Health. Nowadays, the center of external evaluation of quality proposes 100 and more types of control studies and permanently extends their specter starting from interests of different disciplines of clinical medicine. The consistent participation of laboratories in the cycles of external evaluation of quality intrinsically promotes improvement of indicators of properness and precision of analysis results and increases reliability of laboratory information. However, a significant percentage of laboratories does not participate at all in external evaluation of quality or takes part in control process irregularly and in limited number of tests. The managers of a number of medical organizations disregard the application of the proposed possibilities to increase reliability of laboratory information and limit financing of studies in the field of quality control. The article proposes to adopt the national standard on the basis of ISO 17043 "Evaluation of compliance. The common requirements of professional competence testing".
Upper mantle P velocity structure beneath the Baikal Rift from modeling regional seismic data
NASA Astrophysics Data System (ADS)
Brazier, Richard A.; Nyblade, Andrew A.
2003-02-01
Uppermost mantle P wave velocity structure beneath the Baikal rift and southern margin of the Siberian Platform has been investigated by using a grid search method to model Pnl waveforms from two moderate earthquakes recorded by station TLY at the southwestern end of Lake Baikal. The results yielded a limited number of successful models which indicate the presence of upper mantle P wave velocities beneath the rift axis and the margin of the platform that are 2-5% lower than expected. The magnitude of the velocity anomalies and their location support the presence of a thermal anomaly that extends laterally beyond the rift proper, possibly created by small-scale convection or a plume-like, thermal upwelling.
Annoyance due to simulated blade-slap noise
NASA Technical Reports Server (NTRS)
Powell, C. A.
1978-01-01
The effects of several characteristics of blade slap noise on annoyance response were studied. These characteristics or parameters were the sound pressure level of the continuous noise used to simulate helicopter broadband noise, the ratio of impulse peak to broadband noise or crest factor, the number of pressure excursions comprising an impulse event, the rise and fall time of the individual impulses, and the repetition frequency of the impulses. Analyses were conducted to determine the correlation between subjective response and various physical measures for the range of parameters studied. A small but significant improvement in the predictive ability of PNL was provided by an A-weighted crest factor correlation. No significant improvement in predictive ability was provided by a rate correction.
Behavior of complex mixtures in aquatic environments: a synthesis of PNL ecological research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fickeisen, D.H.; Vaughan, B.E.
1984-06-01
The term complex mixture has been recently applied to energy-related process streams, products and wastes that typically contain hundreds or thousands of individual organic compounds, like petroleum or synthetic fuel oils; but it is more generally applicable. A six-year program of ecological research has focused on four areas important to understanding the environmental behavior of complex mixtures: physicochemical variables, individual organism responses, ecosystems-level determinations, and metabolism. Of these areas, physicochemical variables and organism responses were intensively studied; system-level determinations and metabolism represent more recent directions. Chemical characterization was integrated throughout all areas of the program, and state-of-the-art methods were applied.more » 155 references, 35 figures, 4 tables.« less
Does external evaluation of laboratories improve patient safety?
Noble, Michael A
2007-01-01
Laboratory accreditation and External Quality Assessment (also called proficiency testing) are mainstays of laboratory quality assessment and performance. Both practices are associated with examples of improved laboratory performance. The relationship between laboratory performance and improved patient safety is more difficult to assess because of the many variables that are involved with patient outcome. Despite this difficulty, the argument to continue external evaluation of laboratories is too compelling to consider the alternative.
Blank, Melissa D.; Breland, Alison B.; Cobb, Caroline O.; Spindle, Tory; Ramôa, Carolina; Eissenberg, Thomas
2017-01-01
Objective Evaluating electronic cigarettes (ECIGs) in the clinical laboratory is critical to understanding their effects. However, laboratory evaluation of ECIGs can be challenging, as they are a novel, varied, and evolving class of products. The objective of this paper is to describe some methodological challenges to the clinical laboratory evaluation of ECIGs. Methods The authors gathered information about challenges involved in the laboratory evaluation of ECIGs. Challenges were categorized and solutions provided when possible. Results Methods used to study combustible cigarettes may need to be adapted to account for ECIG novelty and differences within the class. Challenges to ECIG evaluation can include issues related to 1) identification of ECIG devices and liquids, 2) determination of short -term ECIG abstinence, 3) measurement of use behavior, and 4) assessment of dependence. These challenges are discussed, and some suggestions to inform ECIG evaluation using clinical laboratory methods are provided. Conclusions Awareness of challenges and developing, validating, and reporting methods used to address them aids interpretation of results and replication efforts, thus enhancing the rigor of science used to protect public health through appropriate, empirically-based, ECIG regulation. PMID:28819633
Blank, Melissa D; Breland, Alison B; Cobb, Caroline O; Spindle, Tory; Ramôa, Carolina; Eissenberg, Thomas
2016-10-01
Evaluating electronic cigarettes (ECIGs) in the clinical laboratory is critical to understanding their effects. However, laboratory evaluation of ECIGs can be challenging, as they are a novel, varied, and evolving class of products. The objective of this paper is to describe some methodological challenges to the clinical laboratory evaluation of ECIGs. The authors gathered information about challenges involved in the laboratory evaluation of ECIGs. Challenges were categorized and solutions provided when possible. Methods used to study combustible cigarettes may need to be adapted to account for ECIG novelty and differences within the class. Challenges to ECIG evaluation can include issues related to 1) identification of ECIG devices and liquids, 2) determination of short -term ECIG abstinence, 3) measurement of use behavior, and 4) assessment of dependence. These challenges are discussed, and some suggestions to inform ECIG evaluation using clinical laboratory methods are provided. Awareness of challenges and developing, validating, and reporting methods used to address them aids interpretation of results and replication efforts, thus enhancing the rigor of science used to protect public health through appropriate, empirically-based, ECIG regulation.
Evaluating Usability in a Distance Digital Systems Laboratory Class
ERIC Educational Resources Information Center
Kostaras, N.; Xenos, M.; Skodras, A. N.
2011-01-01
This paper presents the usability evaluation of a digital systems laboratory class offered to distance-learning students. It details the way in which students can participate remotely in such a laboratory, the methodology employed in the usability assessment of the laboratory infrastructure (hardware and software), and also outlines the main…
Laboratory evaluation of detectors of explosives' effluents
DOT National Transportation Integrated Search
1972-11-30
This document contains the classification, technical description and laboratory evaluation of five commercial detectors for explosives' effluents. It includes an outline of operating principles, test and evaluation procedures. The evaluation is based...
Power source evaluation capabilities at Sandia National Laboratories
DOE Office of Scientific and Technical Information (OSTI.GOV)
Doughty, D.H.; Butler, P.C.
1996-04-01
Sandia National Laboratories maintains one of the most comprehensive power source characterization facilities in the U.S. National Laboratory system. This paper describes the capabilities for evaluation of fuel cell technologies. The facility has a rechargeable battery test laboratory and a test area for performing nondestructive and functional computer-controlled testing of cells and batteries.
The Accreditation Experience of Clinical Laboratories and Blood Banks in Mexico.
Quintana, Sandra
2015-11-01
The accreditation of clinical laboratories and blood banks based on ISO 15189 is now being consolidated in Mexico, and is coordinated by the Mexican accreditation entity innovative strategies, A.C. (ema) and supported by the activities of the committee of clinical laboratories and blood banks. The active participation in working groups formed by the technical committee of clinical laboratories and blood banks in specific areas, has contributed to the formulation of technical documents and criteria of evaluation that strengthen the current accreditation scheme. The national registry of evaluation (PNE) consists of technical experts and evaluators from different disciplines of clinical laboratory; the evaluators actively participate in accreditation assessment, with an ultimate goal to receive training and feedback for continuous improvement of its own performance.
Static performance and noise tests on a thrust reverser for an augmentor wing aircraft
NASA Technical Reports Server (NTRS)
Harkonen, D. L.; Marrs, C. C.; Okeefe, J. V.
1974-01-01
A 1/3 scale model static test program was conducted to measure the noise levels and reverse thrust performance characteristics of wing-mounted thrust reverser that could be used on an advanced augmentor wing airplane. The configuration tested represents only the most fundamental designs where installation and packaging restraints are not considered. The thrust reverser performance is presented in terms of horizontal, vertical, and resultant effectiveness ratios and the reverser noise is compared on the basis of peak perceived noise level (PNL) and one-third octave band data (OASPL). From an analysis of the model force and acoustic data, an assessment is made on the stopping distance versus noise for a 90,900 kg (200,000 lb) airplane using this type of thrust reverser.
NASA Astrophysics Data System (ADS)
Zhang, Chun Mei; Chen, Chao; Sun, Yan; Gou, Bing Cong; Shao, Bin
2015-04-01
The Rayleigh-Ritz variational method with multiconfiguration interaction wave functions is used to obtain the energies of high-lying multi-excited quartet states 1 s 22 s2 pnl and 1 s 22 p 2 nl 4Pe,o ( n ≥ 2) in B-like neon, including the mass polarization and relativistic corrections. The fine structure and hyperfine structure of the excited quartet states for this system are investigated. Configuration structures of the high-lying multi-excited series are further identified by relativistic corrections and fine structure splittings. The transition rates and wavelengths are also calculated. Calculated wavelengths include the quantum electrodynamic effects. The results are compared with other theoretical and experimental data in the literature.
[Asymptomatic kidney stones: active surveillance vs. treatment].
Neisius, A; Thomas, C; Roos, F C; Hampel, C; Fritsche, H-M; Bach, T; Thüroff, J W; Knoll, T
2015-09-01
The prevalence of kidney stones is increasing worldwide. Asymptomatic non-obstructing kidney stones are increasingly detected as an incidental finding on radiologic imaging, which has been performed more frequently over the last decades. Beside the current interventional treatment modalities such as extracorporeal shockwave lithotripsy (ESWL), ureterorenoscopy (URS) and percutaneous nephrolithotomy (PNL), active surveillance of asymptomatic kidney stones has been a focus of discussion lately, not only for attending physicians, but even more so for patients. The current German and European guidelines recommend active surveillance for patients with asymptomatic kidney stones if no interventional therapy is mandatory because of pain or medical factors. Herein we review the current literature on risks and benefits of active surveillance of asymptomatic non-obstructing kidney stones. © Georg Thieme Verlag KG Stuttgart · New York.
Selecting automation for the clinical chemistry laboratory.
Melanson, Stacy E F; Lindeman, Neal I; Jarolim, Petr
2007-07-01
Laboratory automation proposes to improve the quality and efficiency of laboratory operations, and may provide a solution to the quality demands and staff shortages faced by today's clinical laboratories. Several vendors offer automation systems in the United States, with both subtle and obvious differences. Arriving at a decision to automate, and the ensuing evaluation of available products, can be time-consuming and challenging. Although considerable discussion concerning the decision to automate has been published, relatively little attention has been paid to the process of evaluating and selecting automation systems. To outline a process for evaluating and selecting automation systems as a reference for laboratories contemplating laboratory automation. Our Clinical Chemistry Laboratory staff recently evaluated all major laboratory automation systems in the United States, with their respective chemistry and immunochemistry analyzers. Our experience is described and organized according to the selection process, the important considerations in clinical chemistry automation, decisions and implementation, and we give conclusions pertaining to this experience. Including the formation of a committee, workflow analysis, submitting a request for proposal, site visits, and making a final decision, the process of selecting chemistry automation took approximately 14 months. We outline important considerations in automation design, preanalytical processing, analyzer selection, postanalytical storage, and data management. Selecting clinical chemistry laboratory automation is a complex, time-consuming process. Laboratories considering laboratory automation may benefit from the concise overview and narrative and tabular suggestions provided.
Laboratory evaluations of erectile dysfunction: an evidence based approach.
Bodie, Joshua; Lewis, Jean; Schow, Doug; Monga, Manoj
2003-06-01
We evaluate the prevalence of laboratory abnormalities in men presenting for initial evaluation and therapy of erectile dysfunction. The computerized charts of men receiving treatment for erectile dysfunction from 1987 to 2002 were retrospectively reviewed. We pooled laboratory data for 3,547 men with erectile dysfunction to assess the prevalence of laboratory abnormalities. Values of the common laboratory screening tests for erectile dysfunction were recorded for testosterone, prolactin, luteinizing hormone, thyroid-stimulating hormone, hemoglobin A(Ic), prostate specific antigen, hemoglobin, cholesterol and creatinine. Of those patients evaluated 18.7% had low testosterone, 4.6% had increased prolactin, 14.6% had abnormal luteinizing hormone, 4.0% had increased thyroid-stimulating hormone, 8.3% had increased prostate specific antigen, 26.5% had anemia and 11.9% tested had renal insufficiency. A high percentage of patients presenting with a primary complaint of erectile dysfunction had increased hemoglobin A(Ic) and total serum cholesterol levels (52.9% and 48.4%, respectively). An evidence based approach to standardization of laboratory evaluations for men presenting with erectile dysfunction is recommended. Laboratory screening should be directed to identify those risk factors that may benefit from lifestyle modification and pharmacological intervention.
The Accreditation Experience of Clinical Laboratories and Blood Banks in Mexico
2015-01-01
The accreditation of clinical laboratories and blood banks based on ISO 15189 is now being consolidated in Mexico, and is coordinated by the Mexican accreditation entity innovative strategies, A.C. (ema) and supported by the activities of the committee of clinical laboratories and blood banks. The active participation in working groups formed by the technical committee of clinical laboratories and blood banks in specific areas, has contributed to the formulation of technical documents and criteria of evaluation that strengthen the current accreditation scheme. The national registry of evaluation (PNE) consists of technical experts and evaluators from different disciplines of clinical laboratory; the evaluators actively participate in accreditation assessment, with an ultimate goal to receive training and feedback for continuous improvement of its own performance. PMID:27683498
A SIMPLE METHOD FOR EVALUATING DATA FROM AN INTERLABORATORY STUDY
Large-scale laboratory-and method-performance studies involving more than about 30 laboratories may be evaluated by calculating the HORRAT ratio for each test sample (HORRAT=[experimentally found among-laboratories relative standard deviation] divided by [relative standard deviat...
Development, Evaluation, and Application of a Primary Aerosol Model.
Wang, I T; Chico, T; Huang, Y H; Farber, R J
1999-09-01
The Segmented-Plume Primary Aerosol Model (SPPAM) has been developed over the past several years. The earlier model development goals were simply to generalize the widely used Industrial Source Complex Short-Term (ISCST) model to simulate plume transport and dispersion under light wind conditions and to handle a large number of roadway or line sources. The goals have been expanded to include development of improved algorithm for effective plume transport velocity, more accurate and efficient line and area source dispersion algorithms, and recently, a more realistic and computationally efficient algorithm for plume depletion due to particle dry deposition. A performance evaluation of the SPPAM has been carried out using the 1983 PNL dual tracer experimental data. The results show the model predictions to be in good agreement with observations in both plume advection-dispersion and particulate matter (PM) depletion by dry deposition. For PM 2.5 impact analysis, the SPPAM has been applied to the Rubidoux area of California. Emission sources included in the modeling analysis are: paved road dust, diesel vehicular exhaust, gasoline vehicular exhaust, and tire wear particles from a large number of roadways in Rubidoux and surrounding areas. For the selected modeling periods, the predicted primary PM 2.5 to primary PM10 concentration ratios for the Rubidoux sampling station are in the range of 0.39-0.46. The organic fractions of the primary PM 2.5 impacts are estimated to be at least 34-41%. Detailed modeling results indicate that the relatively high organic fractions are primarily due to the proximity of heavily traveled roadways north of the sampling station. The predictions are influenced by a number of factors; principal among them are the receptor locations relative to major roadways, the volume and composition of traffic on these roadways, and the prevailing meteorological conditions.
Gomes, Maria Fernanda Pereira Lavieri; de Oliveira Massoco, Cristina; Xavier, José Guilherme
2010-01-01
Comfrey or Symphytum officinale (L.) (Boraginaceae) is a very popular plant used for therapeutic purposes. Since the 1980s, its effects have been studied in long-term carcinogenesis studies, in which Comfrey extract is administered at high doses during several months and the neoplastic hepatic lesions are evaluated. However, the literature on this topic is very poor considering the studies performed under short-term carcinogenesis protocols, such as the ‘resistant hepatocyte model’ (RHM). In these studies, it is possible to observe easily the phenomena related to the early phases of tumor development, since pre-neoplastic lesions (PNLs) rise in about 1–2 months of chemical induction. Herein, the effects of chronic oral treatment of rats with 10% Comfrey ethanolic extract were evaluated in a RHM. Wistar rats were sequentially treated with N-nitrosodiethylamine (ip) and 2-acetilaminofluorene (po), and submitted to hepatectomy to induce carcinogenesis promotion. Macroscopic/microscopic quantitative analysis of PNL was performed. Non-parametric statistical tests (Mann–Whitney and χ2) were used, and the level of significance was set at P ≤ 0.05. Comfrey treatment reduced the number of pre-neoplastic macroscopic lesions up to 1 mm (P ≤ 0.05), the percentage of oval cells (P = 0.0001) and mitotic figures (P = 0.007), as well as the number of Proliferating Cell Nuclear Antigen (PCNA) positive cells (P = 0.0001) and acidophilic pre-neoplastic nodules (P = 0.05). On the other hand, the percentage of cells presenting megalocytosis (P = 0.0001) and vacuolar degeneration (P = 0.0001) was increased. Scores of fibrosis, glycogen stores and the number of nucleolus organizing regions were not altered. The study indicated that oral treatment of rats with 10% Comfrey alcoholic extract reduced cell proliferation in this model. PMID:18955295
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, C.
1994-10-01
The Department of Energy`s (DOE) Hanford site near Richland, Washington is being cleaned up after 50 years of nuclear materials production. One of the most serious problems at the site is the waste stored in single-shell underground storage tanks. There are 149 of these tanks containing the spent fuel residue remaining after the fuel is dissolved in acid and the desired materials (primarily plutonium and uranium) are separated out. The tanks are upright cylinders 75 ft. in diameter with domed tops. They are made of reinforced concrete, have steel liners, and each tank is buried under 7--12 ft. of overburden.more » The tanks are up to 40-ft. high, and have capacities of 500,000, 750,000, or 1,000,000 gallons of waste. As many as one-third of these tanks are known or suspected to leak. The waste form contained in the tanks varies in consistency from liquid supernatant to peanut-butter-like gels and sludges to hard salt cake (perhaps as hard as low-grade concrete). The current waste retrieval plan is to insert a large long-reach manipulator through a hole cut in the top of the tank, and use a variety of end-effectors to mobilize the waste and remove it from the tank. PNL has, with the assistance of Deneb robotics employees, developed a means of using the IGRIP code to perform parametric design of mechanical systems. This method requires no modifications to the IGRIP code, and all design data are stored in the IGRIP workcell. The method is presented in the context of development of a passive articulated mechanism that is used to deliver down-arm services to a gantry robot. The method is completely general, however, and could be used to design a fully articulated manipulator. Briefly, the method involves using IGCALC expressions to control manipulator joint angles, and IGCALC variables to allow user control of link lengths and offsets. This paper presents the method in detail, with examples drawn from PNL`s experience with the gantry robot service-providing mechanism.« less
Safety in the Chemical Laboratory: Evaluation of Chemical Atmospheres in Science Laboratories.
ERIC Educational Resources Information Center
Renfrew, Malcolm M., Ed.; Bayer, Richard E.
1980-01-01
Recommends that science teachers make evaluations of chemical atmospheres in science laboratories so that serious health problems can be avoided. Uses data from methylene chloride to provide guidelines for understanding the effects of chemicals on the human body. (CS)
Gaspar, Pâmela Cristina; Wohlke, Bruna Lovizutto Protti; Brunialti, Milena Karina Coló; Pires, Ana Flávia; Kohiyama, Igor Massaki; Salomão, Reinaldo; Alonso Neto, José Boullosa; Júnior, Orlando da Costa Ferreira; Franchini, Miriam; Bazzo, Maria Luiza; Benzaken, Adele Schwartz
2018-05-01
The National Network for CD4+ T-lymphocyte counting of Brazil comprises 93 laboratories. This study reports the laboratory performances achieved in external quality assessment (EQA) rounds provides by Ministry of Health to evaluate the quality of the kits used and the performance of test by the technicians.Ten EQA rounds were analyzed according the EQA criteria aimed to evaluate individual laboratory performance on the basis of the accuracy of their results compared to the general mean obtained by all participating laboratories and the reproducibility of the results obtained between 2 samples from the same donor.The percentage of approved and failed laboratories in the EQAs tends to follow a uniform pattern. Since 2011, approval has remained above 80% and the failure rate has never exceeded 15%.EQA is very important to evaluate the performance of the laboratories, to identify monitor, and to resolve errors as quickly as possible.
LABORATORY TOXICITY TESTS FOR EVALUATING POTENTIAL EFFECTS OF ENDOCRINE-DISRUPTING COMPOUNDS
The scope of the Laboratory Testing Work Group was to evaluate methods for testing aquatic and terrestrial invertebrates in the laboratory. Specifically, discussions focused on the following objectives: 1) assess the extent to which consensus-based standard methods and other pub...
So, Jane; Young, Elizabeth; Crnosija, Natalie; Chappelle, Joseph
2016-04-01
Preeclampsia is the 2nd leading cause of maternal mortality in the United States. Women with new-onset or worsening hypertension are commonly evaluated for laboratory abnormalities. We aim to investigate whether demographic and/or clinical findings correlate with abnormal laboratory values. A retrospective chart review of women who presented for evaluation of hypertension in pregnancy during 2010. Demographic information, medical history, symptoms, vital signs, and laboratory results were collected. Bivariate analysis was used to investigate associations between predictors and the outcome. Of the 481 women in the sample, 22 were identified as having abnormal laboratory test results (4.6%). Women who reported right upper quadrant pain or tenderness had significantly increased likelihood of having laboratory abnormalities compared to those without the complaint. Only a small percentage of women evaluated were determined to have abnormal laboratory findings, predominantly among women with severe preeclampsia. Right upper quadrant pain or tenderness was positively correlated with laboratory abnormalities. The restriction of laboratory analysis in women with clinical evidence of severe disease may be warranted - a broader study should, however, first be used to confirm our findings.
Evaluating Technology Transfer and Diffusion.
ERIC Educational Resources Information Center
Bozeman, Barry; And Others
1988-01-01
Four articles discuss the evaluation of technology transfer and diffusion: (1) "Technology Transfer at the U.S. National Laboratories: A Framework for Evaluation"; (2) "Application of Social Psychological and Evaluation Research: Lessons from Energy Information Programs"; (3) "Technology and Knowledge Transfer in Energy R and D Laboratories: An…
NASA Astrophysics Data System (ADS)
Konca, A.
2013-12-01
A kinematic model for the Mw7.1 2011 Van Earthquake was obtained using regional, teleseismic and GPS data. One issue regarding regional data is that 1D Green's functions may not be appropriate due to complications in the upper mantle and crust that affects the Pnl waveforms. In order to resolve whether the 1D Green's function is appropriate, an aftershock of the main event was also modeled, which is then used as a criterion in the selection of the regional stations. The GPS data itself is not sufficient to obtain a slip model, but helps constrain the slip distribution. The slip distribution is up-dip and bilateral with more slip toward west, where the maximum slip reaches 4 meters. The rupture velocity is about 1.5 km/s.
gpICA: A Novel Nonlinear ICA Algorithm Using Geometric Linearization
NASA Astrophysics Data System (ADS)
Nguyen, Thang Viet; Patra, Jagdish Chandra; Emmanuel, Sabu
2006-12-01
A new geometric approach for nonlinear independent component analysis (ICA) is presented in this paper. Nonlinear environment is modeled by the popular post nonlinear (PNL) scheme. To eliminate the nonlinearity in the observed signals, a novel linearizing method named as geometric post nonlinear ICA (gpICA) is introduced. Thereafter, a basic linear ICA is applied on these linearized signals to estimate the unknown sources. The proposed method is motivated by the fact that in a multidimensional space, a nonlinear mixture is represented by a nonlinear surface while a linear mixture is represented by a plane, a special form of the surface. Therefore, by geometrically transforming the surface representing a nonlinear mixture into a plane, the mixture can be linearized. Through simulations on different data sets, superior performance of gpICA algorithm has been shown with respect to other algorithms.
NASA Technical Reports Server (NTRS)
Kazin, S. B.
1973-01-01
Acoustic tests were conducted on a high tip speed (1550 ft/sec, 472.44 m/sec) single stage fan with varying amounts of wall acoustic treatment and with circumferential slots over the rotor blade tips. The slots were also tested with acoustic treatment placed behind the slots. The wall treatment results show that the inlet treatment is more effective at high fan speeds and aft duct treatment is more effective at low fan speeds. Maximum PNL's on a 200-foot (60.96 m) sideline show the untreated slots to have increased the rear radiated noise at approach. However, when the treatment was added to the slots inlet radiated noise was decreased, resulting in little change relative to the solid casing on an EPNL basis.
Quality Evaluation of Coatings by Automatic Scratch Testing
1989-11-01
MTL TR 89-98 IADII QUALITY EVALUATION OF COATINGS BY AUTOMATIC SCRATCH TESTING KIRIT J. BHANSALI LBRTR A1 U.S. ARMY MATERIALS TECHNOLOGY LABORATORY...distribution unlimited. LABORATORY COMMANO U.S. ARMY MATERIALS TECHNOLOGY LABORATORY PMUNKS wcamaauv LUaAMUv Watertown, Massachusetts 02172-0001 .o...Theo 7- Kattamis* 9 PEWNWING ORGANIZATION NAME AMO ADDRESS 1.PORUEEET RJC.TS AREA & WORK UNIT NUMSS U.S. Army Materials Technology Laboratory Watertown
Diagnostic Testing and Interpretation of Tests for Autoimmunity
Castro, Christine; Gourley, Mark
2010-01-01
Laboratory testing is of great value when evaluating a patient with a suspected autoimmune disease. The results can confirm a diagnosis, estimate disease severity, aid in assessing prognosis and are useful to follow disease activity. Components of the laboratory exam include complete blood count with differential, comprehensive metabolic panel, inflammatory markers, autoantibodies, and flow cytometry. This chapter discusses these components and includes a discussion about organ-specific immunologic diseases where immunological laboratory testing is employed. Comprehensive laboratory evaluation of a suspected autoimmune illness in conjunction with a thorough clinical evaluation provides a better understanding of a patient's immunologic disease. PMID:20061009
Woodworth, M.T.; Connor, B.F.
2001-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-165 (trace constituents), M-158 (major constituents), N-69 (nutrient constituents), N-70 (nutrient constituents), P-36 (low ionic-strength constituents), and Hg-32 (mercury) -- that were distributed in April 2001 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 73 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Woodworth, M.T.; Conner, B.F.
2002-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T- 169 (trace constituents), M- 162 (major constituents), N-73 (nutrient constituents), N-74 (nutrient constituents), P-38 (low ionic-strength constituents), and Hg-34 (mercury) -- that were distributed in March 2002 to laboratories enrolled in the U.S. Geological Survey sponsored intedaboratory testing program. Analytical data received from 93 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Woodworth, Mark T.; Connor, Brooke F.
2003-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-171 (trace constituents), M-164 (major constituents), N-75 (nutrient constituents), N-76 (nutrient constituents), P-39 (low ionic-strength constituents), and Hg-35 (mercury) -- that were distributed in September 2002 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 102 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Woodworth, Mark T.; Connor, Brooke F.
2002-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-167 (trace constituents), M-160 (major constituents), N-71 (nutrient constituents), N-72 (nutrient constituents), P-37 (low ionic-strength constituents), and Hg-33 (mercury) -- that were distributed in September 2001 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 98 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Farrar, Jerry W.; Copen, Ashley M.
2000-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-161 (trace constituents), M-154 (major constituents), N-65 (nutrient constituents), N-66 nutrient constituents), P-34 (low ionic strength constituents), and Hg-30 (mercury) -- that were distributed in March 2000 to 144 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 132 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Farrar, T.W.
2000-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-159 (trace constituents), M-152 (major constituents), N-63 (nutrient constituents), N-64 (nutrient constituents), P-33 (low ionic strength constituents), and Hg-29 (mercury) -- that were distributed in October 1999 to 149 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 131 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Woodworth, Mark T.; Connor, Brooke F.
2003-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-173 (trace constituents), M-166 (major constituents), N-77 (nutrient constituents), N-78 (nutrient constituents), P-40 (low ionic-strength constituents), and Hg-36 (mercury) -- that were distributed in March 2003 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 110 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Connor, B.F.; Currier, J.P.; Woodworth, M.T.
2001-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-163 (trace constituents), M-156 (major constituents), N-67 (nutrient constituents), N-68 (nutrient constituents), P-35 (low ionic strength constituents), and Hg-31 (mercury) -- that were distributed in October 2000 to 126 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 122 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
External Performance Evaluation Program Participation at Fluor Hanford (FH) 222S Lab
DOE Office of Scientific and Technical Information (OSTI.GOV)
CLARK, G.A.
2002-06-01
Fluor Hanford operates the U. S. Department of Energy's (DOE) 2224 Laboratory on the Hanford Site in Southeastern Washington State. 222-S Laboratory recently celebrated its 50th anniversary of providing laboratory services to DOE and DOE contractors on the Hanford Site. The laboratory operated for many years as a production support analytical laboratory, but in the last two decades has supported the Hanford Site cleanup mission. The laboratory performs radioanalytical, inorganic, and organic characterization analyses on highly radioactive liquid and solid tank waste that will eventually be vitrified for long-term storage and or disposal. It is essential that the laboratory reportmore » defensible, highly credible data in its role as a service provider to DOE and DOE contractors. Among other things, the participation in a number of performance evaluation (PE) programs helps to ensure the credibility of the laboratory. The laboratory currently participates in Environmental Resource Associates' Water Pollution (WP) Studies and the DOE Environmental Management Laboratory (EML) Quality Assessment Program (QAP). DOE has mandated participation of the laboratory in the EML QAP. This EML program evaluates the competence of laboratories performing environmental radioanalytical measurements for DOE, and is the most comprehensive and well-established PE program in the DOE community for radiochemical laboratories. Samples are received and analyzed for radionuclides in air filter, soil, vegetation, and water matrices on a semiannual basis. The 222-S Laboratory has performed well in this program over the years as evidenced by the scores in the chart below.« less
NASA Astrophysics Data System (ADS)
Nikolic, Sasha; Suesse, Thomas F.; McCarthy, Timothy J.; Goldfinch, Thomas L.
2017-11-01
Minimal research papers have investigated the use of student evaluations on the laboratory, a learning medium usually run by teaching assistants with little control of the content, delivery and equipment. Finding the right mix of teaching assistants for the laboratory can be an onerous task due to the many skills required including theoretical and practical know-how, troubleshooting, safety and class management. Using larger classes with multiple teaching assistants, a team-based teaching (TBT) format may be advantageous. A rigorous three-year study across twenty-five courses over repetitive laboratory classes is analysed using a multi-level statistical model considering students, laboratory classes and courses. The study is used to investigate the effectiveness of the TBT format, and quantify the influence each demonstrator has on the laboratory experience. The study found that TBT is effective and the lead demonstrator most influential, influencing up to 55% of the laboratory experience evaluation.
External quality assessment for CD4 + T-lymphocyte count test
Gaspar, Pâmela Cristina; Wohlke, Bruna Lovizutto Protti; Brunialti, Milena Karina Coló; Pires, Ana Flávia; Kohiyama, Igor Massaki; Salomão, Reinaldo; Alonso Neto, José Boullosa; Júnior, Orlando da Costa Ferreira; Franchini, Miriam; Bazzo, Maria Luiza; Benzaken, Adele Schwartz
2018-01-01
Abstract The National Network for CD4+ T-lymphocyte counting of Brazil comprises 93 laboratories. This study reports the laboratory performances achieved in external quality assessment (EQA) rounds provides by Ministry of Health to evaluate the quality of the kits used and the performance of test by the technicians. Ten EQA rounds were analyzed according the EQA criteria aimed to evaluate individual laboratory performance on the basis of the accuracy of their results compared to the general mean obtained by all participating laboratories and the reproducibility of the results obtained between 2 samples from the same donor. The percentage of approved and failed laboratories in the EQAs tends to follow a uniform pattern. Since 2011, approval has remained above 80% and the failure rate has never exceeded 15%. EQA is very important to evaluate the performance of the laboratories, to identify monitor, and to resolve errors as quickly as possible. PMID:29794603
Evaluation of a nuclear asphalt content gage : final report.
DOT National Transportation Integrated Search
1970-01-01
The Troxler Model 2226 asphalt content gauge was evaluated in the laboratory and taken into the field where its results were compared to conventional reflux values. The precision as evaluated in the laboratory was found to be excellent - equivalent t...
ERIC Educational Resources Information Center
Edward, Norrie S.
1997-01-01
Evaluates the importance of realism in the screen presentation of the plant in computer-based laboratory simulations for part-time engineering students. Concludes that simulations are less effective than actual laboratories but that realism minimizes the disadvantages. The schematic approach was preferred for ease of use. (AIM)
ERIC Educational Resources Information Center
Bruce, A. Wayne
1986-01-01
Describes reasons for developing combined text and computer assisted instruction (CAI) teaching programs for delivery of continuing education to laboratory professionals, and mechanisms used for developing a CAI program on method evaluation in the clinical laboratory. Results of an evaluation of the software's cost effectiveness and instructional…
DOT National Transportation Integrated Search
2001-06-01
Volume 2 documents laboratory and field testing that provides the evidence that microdamage healing is real and measurable and that it has a significant impact on pavement performance. Part of the laboratory experiments to evaluate the impact of rest...
Laboratory evaluation of Honeywell polymer vs SBS polymer modified asphalt mixtures.
DOT National Transportation Integrated Search
2013-05-01
The scope of the study is to evaluate the laboratory performance of two asphalt mixtures; : one modified with SBS polymer and the second modified with a polymer from : Honeywell. Both asphalt binder and mixture properties are proposed to be evaluated...
As a part of the Superfund Innovative Technology Evaluation (SITE) Program, the U.S. Environmental Protection Agency evaluated the In-Situ Electrokinetic Extraction (ISEE) system at Sandia National Laboratories, Albuquerque, New Mexico.
The SITE demonstration results show ...
Moving from Batch to Field Using the RT3D Reactive Transport Modeling System
NASA Astrophysics Data System (ADS)
Clement, T. P.; Gautam, T. R.
2002-12-01
The public domain reactive transport code RT3D (Clement, 1997) is a general-purpose numerical code for solving coupled, multi-species reactive transport in saturated groundwater systems. The code uses MODFLOW to simulate flow and several modules of MT3DMS to simulate the advection and dispersion processes. RT3D employs the operator-split strategy which allows the code solve the coupled reactive transport problem in a modular fashion. The coupling between reaction and transport is defined through a separate module where the reaction equations are specified. The code supports a versatile user-defined reaction option that allows users to define their own reaction system through a Fortran-90 subroutine, known as the RT3D-reaction package. Further a utility code, known as BATCHRXN, allows the users to independently test and debug their reaction package. To analyze a new reaction system at a batch scale, users should first run BATCHRXN to test the ability of their reaction package to model the batch data. After testing, the reaction package can simply be ported to the RT3D environment to study the model response under 1-, 2-, or 3-dimensional transport conditions. This paper presents example problems that demonstrate the methods for moving from batch to field-scale simulations using BATCHRXN and RT3D codes. The first example describes a simple first-order reaction system for simulating the sequential degradation of Tetrachloroethene (PCE) and its daughter products. The second example uses a relatively complex reaction system for describing the multiple degradation pathways of Tetrachloroethane (PCA) and its daughter products. References 1) Clement, T.P, RT3D - A modular computer code for simulating reactive multi-species transport in 3-Dimensional groundwater aquifers, Battelle Pacific Northwest National Laboratory Research Report, PNNL-SA-28967, September, 1997. Available at: http://bioprocess.pnl.gov/rt3d.htm.
Thermally driven up-slope flows: state of the art and open questions
NASA Astrophysics Data System (ADS)
Zardi, D.
2015-12-01
Thermally driven flows over simple slopes are a relevant research topic, not only per se, but also as a source of key concepts for understanding and modelling many other flows over more complex topographies. However, compared to down-slope, up-slope flows have received much less attention in the literature. Indeed, to investigate katabatic winds many extensive and well equipped field measurements were performed in recent years under various research projects, and a series of high-resolution numerical simulations were run. On the contrary, few field experiments have provided detailed datasets documenting the development of anabatic flows, and the analysis of numerical investigations still relies on Schumann's (1990) pioneering LES simulations. Also, analytic solutions - such as Prandtl's (1942) constant-K profiles - reproduce fairly well katabatic flows, but are definitely inadequate to accurately reproduce field data for up-slope flows (Defant 1949). In particular, some open questions still claim for further investigations, such as the conditions of instability of slope-parallel flow vs. vertical motions, and the related possible occurrence of flow separation, and the similarity analysis of slope-normal velocity profiles of temperature anomaly, wind intensity and turbulence related quantities. Here a review of the state of the art on the subject is proposed, along with some insights into possible future developments. ReferencesDefant, F., 1949: Zur Theorie der Hangwinde, nebst Bemerkungen zur Theorie der Berg- und Talwinde. [A theory of slope winds, along with remarks on the theory of mountain winds and valley winds]. Arch. Meteor. Geophys. Bioclimatol., Ser. A, 1, 421-450 (Theoretical and Applied Climatology). [English translation: Whiteman, C.D., and E. Dreiseitl, 1984: Alpine meteorology: Translations of classic contributions by A. Wagner, E. Ekhart and F. Defant. PNL-5141 / ASCOT-84-3. Pacific Northwest Laboratory, Richland, Washington, 121 pp]. Prandtl, L., 1942: Strömungslehre [Flow Studies]. Vieweg und Sohn, Braunschweig, 382 pp. Schumann, U., 1990: Large-eddy simulation of the up-slope boundary layer. Quart. J. Roy. Meteor. Soc., 116, 637-670.
Leung, Elaine; Dix, David; Ford, Jason; Barnard, Dorothy; McBride, Eileen
2015-11-01
Pediatric hematologists/oncologists need to be skilled clinicians, and must also be adept and knowledgeable in relevant areas of laboratory medicine. Canadian training programs in this subspecialty have a minimum requirement for 6 months of training in acquiring "relevant laboratory diagnostic skills." The Canadian pediatric hematology/oncology (PHO) national specialty society, C17, recognized the need for an assessment method in laboratory skills for fellows graduating from PHO training programs. Canadian pediatric hematologists/oncologists were surveyed regarding what were felt to be the essential laboratory-related knowledge and skills deemed necessary for graduating pediatric hematology/oncology trainees. The PHOELIX (Pediatric hematology/oncology educational laboratory in-training examination) was then developed to provide an annual formative evaluation of laboratory skills in Canadian PHO trainees. The majority of PHO respondents (89%) felt that laboratory skills are important in clinical practice. An annual formative examination including review of glass slides was implemented starting in 2010; this provides feedback regarding knowledge of laboratory medicine to both trainees and program directors (PDs). We have successfully created a formative examination that can be used to evaluate and educate trainees, as well as provide PDs with a tool to gauge the effectiveness of their laboratory training curriculum. Feedback has been positive from both trainees and PDs. © 2015 Wiley Periodicals, Inc.
Benson, Sarah J; Lennard, Christopher J; Maynard, Philip; Hill, David M; Andrew, Anita S; Neal, Ken; Stuart-Williams, Hilary; Hope, Janet; Walker, G Stewart; Roux, Claude
2010-01-01
Comparability of data over time and between laboratories is a key issue for consideration in the development of global databases, and more broadly for quality assurance in general. One mechanism that can be utilized for evaluating traceability is an inter-laboratory trial. This paper addresses an inter-laboratory trial conducted across a number of Australian and New Zealand isotope ratio mass spectrometry (IRMS) laboratories. The main objective of this trial was to determine whether IRMS laboratories in these countries would record comparable values for the distributed samples. Four carbon containing and four nitrogen containing compounds were distributed to seven laboratories in Australia and one in New Zealand. The laboratories were requested to analyze the samples using their standard procedures. The data from each laboratory was evaluated collectively using International Standard ISO 13528 (Statistical methods for use in proficiency testing by inter-laboratory comparisons). "Warning signals" were raised against one participant in this trial. "Action signals" requiring corrective action were raised against four participants. These participants reviewed the data and possible sources for the discrepancies. This inter-laboratory trial was successful in providing an initial snapshot of the potential for traceability between the participating laboratories. The statistical methods described in this article could be used as a model for others needing to evaluate stable isotope results derived from multiple laboratories, e.g., inter-laboratory trials/proficiency testing. Ongoing trials will be conducted to improve traceability across the Australian and New Zealand IRMS community.
Ajzner, Éva; Rogic, Dunja; Meijer, Piet; Kristoffersen, Ann Helen; Carraro, Paolo; Sozmen, Eser; Faria, Ana Paula; Sandberg, Sverre
2015-09-01
An unexpectedly detected prolonged activated partial thromboplastin time (APTT) can be a harmless laboratory finding, but can also reflect a thrombotic tendency or a bleeding disorder. The assistance of laboratory professionals in the interpretation of an unexpectedly detected prolonged APTT (uAPTT) is often required. The way in which uAPTTs are evaluated in laboratories was assessed in this international study with the aim of determining whether laboratory professionals are able to fulfill this need. Postanalytical practices after uAPTT were investigated and the mixing study methodology (if used) was studied by circulating a case report with a questionnaire to staff in the invited laboratories. In addition, the interpretations of those staff regarding the presence or absence of inhibitors in three APTT mixing study scenarios were examined. Large within- and between-country variations were detected in both postanalytical practices and mixing study methodologies among the 990 responding laboratories, 90% of which were in 13 countries. Shortcomings regarding the investigation of uAPTTs leading to potentially incorrect or delayed clinical diagnoses were found in 88% of the laboratories. Of the laboratories to which the interpretative questions were sent, 49% interpreted all mixing study scenarios correctly. uAPTTs were investigated appropriately and all mixing study scenarios interpreted correctly in parallel in only 9.6% of the participating laboratories. The clinical requirement for the assistance of laboratory professionals in the interpretation of uAPTTs cannot be met at most of the participating laboratories. Laboratory professionals should be trained in the evaluation of ordinary laboratory tests, such as that for uAPTTs.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-12
... ENVIRONMENTAL PROTECTION AGENCY [EPA-HQ-OECA-2013-0413; FRL--9832-8] Proposed Information Collection Request; Comment Request; Performance Evaluation Studies on Wastewater Laboratories (Renewal); EPA... request (ICR), ``Performance Evaluation Studies on Wastewater Laboratories'' (EPA ICR No. 0234.11, OMB...
Djangirova, T V; Shabalova, I P; Pronichev, A N; Polyakov, E V
2015-08-01
The article considers application of technology of analysis of cytological slides in external quality control of clinical diagnostic laboratories. The advantages of virtual slides are demonstrated against other applied technologies of external evaluation of quality i.e. slide plate and digital micro-photography. The conditions of formation of virtual slides for external evaluation of quality of clinical diagnostic laboratories. The technology of their application is described. The success of practical application of considered technology in the Federal system of external evaluation of quality is emphasized.
Upward Flame Propagation and Wire Insulation Flammability: 2006 Round Robin Data Analysis
NASA Technical Reports Server (NTRS)
Hirsch, David B.
2007-01-01
This viewgraph document reviews test results from tests of different material used for wire insulation for flame propagation and flammability. The presentation focused on investigating data variability both within and between laboratories; evaluated the between-laboratory consistency through consistency statistic h, which indicates how one laboratory s cell average compares with averages from other labs; evaluated the within-laboratory consistency through the consistency statistic k, which is an indicator of how one laboratory s within-laboratory variability compares with the variability of other labs combined; and extreme results were tested to determine whether they resulted by chance or from nonrandom causes (human error, instrument calibration shift, non-adherence to procedures, etc.)
Farrar, Jerry W.; Long, H. Keith
1996-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for 6 standard reference samples--T-137 (trace constituents), M-136 (major constituents), N-47 (nutrient constituents), N-48 (nutrient constituents), P-25 (low ionic strength constituents), and Hg-21 (mercury)--that were distributed in October 1995 to 149 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 136 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Long, H. Keith; Farrar, Jerry W.
1994-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for five standard reference samples--T-129 (trace constituents), M-130 (major constituents), N-42 (nutrients), P-22 (low ionic strength), Hg-18(mercury),--that were distributed in April 1994 to 157 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 133 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the five reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the five standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Long, H.K.; Farrar, J.W.
1993-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for seven standard reference samples--T-123 (trace constituents), T-125 (trace constituents), M-126 (major constituents), N-38 (nutrients), N-39 (Nutrients), P-20 (precipitation-low ionic strength), and Hg-16 (mercury)--that were distributed in April 1993 to 175 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 131 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the 7 reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the seven standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Farrar, Jerry W.; Chleboun, Kimberly M.
1999-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for 8 standard reference samples -- T-157 (trace constituents), M-150 (major constituents), N-61 (nutrient constituents), N-62 (nutrient constituents), P-32 (low ionic strength constituents), GWT-5 (ground-water trace constituents), GWM- 4 (ground-water major constituents),and Hg-28 (mercury) -- that were distributed in March 1999 to 120 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 111 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the seven reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the 8 standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Manganese recycling in the United States in 1998
Jones, Thomas S.
2003-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-163 (trace constituents), M-156 (major constituents), N-67 (nutrient constituents), N-68 (nutrient constituents), P-35 (low ionic strength constituents), and Hg-31 (mercury) -- that were distributed in October 2000 to 126 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 122 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-16
...; Performance Evaluation Studies on Wastewater Laboratories (Renewal) AGENCY: Environmental Protection Agency... Evaluation Studies on Wastewater Laboratories (Renewal) ICR numbers: EPA ICR No. 0234.10, OMB Control No...
ERIC Educational Resources Information Center
Flaherty, A.; O'Dwyer, A.; Mannix-McNamara, P.; Leahy, J. J.
2017-01-01
Designing and evaluating teacher development programs for graduate teaching assistants (GTAs) who teach in the laboratory is a prominent feature of chemistry education research. However, few studies have investigated the impact of a GTA teacher development program on the verbal interactions between participating GTAs and students in the…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-19
... Employees From Oak Ridge National Laboratory (X-10), Oak Ridge, TN, To Be Included in the Special Exposure... decision to evaluate a petition to designate a class of employees from Oak Ridge National Laboratory (X-10... Laboratory (X-10) Location: Oak Ridge, Tennessee. Job Titles and/or Job Duties: All contractor employees...
[Evaluation on running status of Chinese Polio Laboratories Network in 2008].
Zhu, Shuang-li; Yan, Dong-mei; Zhu, Hui
2010-04-01
In order to evaluate the running status and provide the laboratory data for maintaining polio-free status in China, the virology surveillance database of Chinese Polio Laboratories Network (not include Hong Kong, Macao, and Taiwan)in 2008 were analyzed. The case investigation data of Acute Flaccid Paralysis(AFP)cases reported by 31 provinces (municipal, autonomous regions) through EPI surveillance information management system and the database of National Polio Laboratory (NPL) were analyzed, and the indicators of running status of Chinese Polio Laboratories Network were evaluated. 10,116 stool samples were collected from 5116 AFP cases by Chinese Polio Laboratories Network in 2008, and viral isolation and identification of all stool samples were done according to 4th World Health Organization (WHO) Polio Laboratory Manual. The rate of viral isolation and identification performed within 28d was 94.9%. 189 polioviruses (PV) and 597 of non-polio enteroviruses (NPEV) were isolated from AFP cases, the isolatien rates were 3.72% and 11.74% respectively. 251 polio positive isolates were sent to NPL from 31 provincial polio laboratories. There were 318 single serotype PVs were performed VPI sequencing. And no wild polioviruses and Vaccine-derived Polioviruses (VDPVs) were found in 2008. NPL passed the proficiency test and got full accreditation for on-site review by WHO experts in 2008. All 31 provincial Polio laboratories passed the proficiency test with the same panel as NPL, and 13 provincial Polio laboratories joined and passed the on-site review by WHO experts. The running status of Chinese Polio Laboratories Network was good, polio-free status was maintained in China in 2008. The Chinese polio laboratories network running is normaly, the laboratory surveillance system was sensitive and laboratory data were provided for maintaining the polio-free status in China.
Guide of good practices for occupational radiological protection in plutonium facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-06-01
This Technical Standard (TS) does not contain any new requirements. Its purpose is to provide guides to good practice, update existing reference material, and discuss practical lessons learned relevant to the safe handling of plutonium. the technical rationale is given to allow US Department of Energy (DOE) health physicists to adapt the recommendations to similar situations throughout the DOE complex. Generally, DOE contractor health physicists will be responsible to implement radiation protection activities at DOE facilities and DOE health physicists will be responsible for oversight of those activities. This guidance is meant to be useful for both efforts. This TSmore » replaces PNL-6534, Health Physics Manual of Good Practices for Plutonium Facilities, by providing more complete and current information and by emphasizing the situations that are typical of DOE`s current plutonium operations; safe storage, decontamination, and decommissioning (environmental restoration); and weapons disassembly.« less
A statistical framework for protein quantitation in bottom-up MS-based proteomics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karpievitch, Yuliya; Stanley, Jeffrey R.; Taverner, Thomas
2009-08-15
ABSTRACT Motivation: Quantitative mass spectrometry-based proteomics requires protein-level estimates and confidence measures. Challenges include the presence of low-quality or incorrectly identified peptides and widespread, informative, missing data. Furthermore, models are required for rolling peptide-level information up to the protein level. Results: We present a statistical model for protein abundance in terms of peptide peak intensities, applicable to both label-based and label-free quantitation experiments. The model allows for both random and censoring missingness mechanisms and provides naturally for protein-level estimates and confidence measures. The model is also used to derive automated filtering and imputation routines. Three LC-MS datasets are used tomore » illustrate the methods. Availability: The software has been made available in the open-source proteomics platform DAnTE (Polpitiya et al. (2008)) (http://omics.pnl.gov/software/). Contact: adabney@stat.tamu.edu« less
Turbulent wind at the equatorial segment of an operating Darrieus wind turbine blade
NASA Astrophysics Data System (ADS)
Connell, J. R.; Morris, V. R.
1989-09-01
Six turbulent wind time series, measured at equally spaced equator-height locations on a circle 3 m outside a 34-m Darrieus rotor, are analyzed to approximate the wind fluctuations experienced by the rotor. The flatwise lower root-bending stress of one blade was concurrently recorded. The wind data are analyzed in three ways: wind components that are radial and tangential to the rotation of a blade were rotationally sampled; induction and wake effects of the rotor were estimated from the six Eulerian time series; and turbulence spectra of both the measured wind and the modeled wind from the PNL theory of rotationally sampled turbulence. The wind and the rotor response are related by computing the spectral response function of the flatwise lower root-bending stress. Two bands of resonant response that surround the first and second flatwise modal frequencies shift with the rotor rotation rate.
Fibrosarcoma of the eyelid in two sibling Czech wolfdogs
Nordio, Laura; Fattori, Sabina; Giudice, Chiara
2017-01-01
Most canine tumors of the eyelid are tumors generally encountered in the skin. They are most commonly of epithelial origin and benign. In this report, we describe the cases of two sibling Czech wolfdogs presented, one year apart, with a subcutaneous mass involving the left eyelid. Both lesions were histologically consistent with a diagnosis of subcutaneous fibrosarcoma. Immunohistochemical analyses of the tumors revealed a mild positivity for vimentin and negativity for GFAP, desmin, αSMA, myoglobin, S100, PNL2 and calponin, excluding all differential diagnosis (i.e. peripheral nerve sheath tumor, melanoma, perivascular sarcoma, myofibroblastic sarcoma, rhabdomyosarcoma). To the best of authors’ knowledge, this is the first report of canine eyelid fibrosarcoma. Since this rare tumor has been observed in two full siblings, we could speculate the existence of some genetic predisposition to sarcoma, however the present data did not allow any definite conclusion on the etiopathogenesis or genetic basis of these tumors. PMID:28616389
NASA Astrophysics Data System (ADS)
Ren, Guoli; Pei, Wenbing; Lan, Ke; Gu, Peijun; Li, Xin; Institute of Applied Physics; Computional Mathematics Team
2011-10-01
In current routine 2D simulation of hohlraum physics, we adopt the principal-quantum- number(n-level) average atom model(AAM). However, the experimental frequency-dependant radiative drive differs from our n-level simulated drive, which reminds us the need of a more detailed atomic kinetics description. The orbital-quantum-number(nl-level) AAM is a natural consideration but the in-line calculation consumes much more resources. We use a new method to built up a nl-level bound electron distribution using in-line n-level calculated plasma condition (such as temperature, density, average ionization degree). We name this method ``quasi-steady approximation.'' Using the re-built nl-level bound electron distribution (Pnl) , we acquire a new hohlraum radiative drive by post-processing. Comparison with the n-level post-processed hohlraum drive shows that we get an almost identical radiation flux but with more-detailed frequency-dependant structures.
NASA Astrophysics Data System (ADS)
Rieth, M.; Dafferner, B.
1996-10-01
In the last few years a lot of different low activation CrWVTa steels have been developed world-wide. Without irradiation some of these alloys show clearly a better low temperature embrittlement behaviour than commercial CrNiMoV(Nb) alloys. Within the MANITU project a study was carried out to compare, prior to the irradiation program, the embrittlement behaviour of different alloys in the unirradiated condition performing instrumented Charpy impact bending tests with sub-size specimens. The low activation materials (LAM) considered were different OPTIFER alloys (Forschungszentrum Karlsruhe), F82H (JAERI), 9Cr2WVTa (ORNL), and GA3X (PNL). The modified commercial 10-11% CrNiMoVNb steels were MANET and OPTIMAR. A meaningful comparison between these alloys could be drawn, since the specimens of all materials were manufactured and tested under the same conditions.