Sample records for laboratory pnl operated

  1. Hemostasis in tubeless PNL: point of technique.

    PubMed

    Aron, Monish; Goel, Rajiv; Kesarwani, Pawan K; Gupta, Narmada P

    2004-01-01

    Tubeless PNL (percutaneous nephrolithotomy), in a highly selected group of patients, is a modification aimed at reducing the morbidity of PNL. We present a simple technique of achieving tract hemostasis as an adjunct to the safe performance of a tubeless PNL. Charts of 40 consecutive patients who underwent tubeless PNL at our center were reviewed. In the latter 20 consecutive patients, diathermy coagulation of the intrarenal bleeders and tract was done and these patients were compared with the earlier 20 patients in whom fulguration was not done. Drop in hemoglobin, postoperative analgesic requirement, operating time, length of hospitalization and postoperative complications were compared. No statistical difference was found between the operative times and drop in hemoglobin for both the groups. The length of hospitalization and postoperative analgesic requirement were significantly less in the fulguration group. No significant complications were noted in either of the two groups. Fulguration of visible intrarenal and tract bleeders is a simple, safe and effective hemostatic adjunct in patients undergoing tubeless PNL. copyright 2004 S. Karger AG, Basel

  2. Ultrasonography-guided PNL in comparison with laparoscopic ureterolithotomy in the management of large proximal ureteral stone.

    PubMed

    Karami, Hossein; Mazloomfard, Mohammad Mohsen; Lotfi, Behzad; Alizadeh, Asghar; Javanmard, Babak

    2013-01-01

    The aim of study was to evaluate the clinical outcomes of PNL in comparison with laparoscopic ureterolithotomy (LUL) in proximal ureteral stones larger than 1 cm. A total of 80 patients who were candidates for treatment of large ureteral stones in our urology center were enrolled in the study between September 2004 and September 2008. By using patient randomization, they were assigned into two forty-patient groups (PNL and LUL). After evaluating the patients with laboratory tests and IVP, PNL was performed under sonography guidance in the prone position or the patients were submitted to classic laparoscopic ureterolithotomy (LUL) transperitoneally. All patients underwent postoperative assessments including KUB and ultrasonography. A hundred-percent success was achieved in both groups. The mean age of the patients were 39.4 (16-63) and 35.2 (18-57) years old in PNL and LUL groups, respectively. The mean stone size in PNL group was 14.2 (10-25) mm and in LUL group was 13.5 (10-28) mm. The duration of the operations were 54.35 (50-82) minutes, and 82.15 (73-180) minutes (P < 0.0001); and the average hospital stay days were 2.6 (2-5) and 3.5 (3-8) days (p = 0.011) in groups PNL and LUL, accordingly. The mean Hb decrease in PNL group was 0.9mg/dL and in LUL group was 0.4mg/dL (p = 0.001). No statistically significant differences in terms of blood transfusion, fever, ICU admission, and prolonged urinary leakage were detected in both groups. According to our study, percutaneous nephrolithotomy under ultrasonography guidance is comparable with the laparoscopic ureterolithotomy for the treatment of proximal ureteral stones larger than 1 cm.

  3. Prospective comparative study of miniperc and standard PNL for treatment of 1 to 2 cm size renal stone.

    PubMed

    Mishra, Shashikant; Sharma, Rajan; Garg, Chandrapraksh; Kurien, Abraham; Sabnis, Ravindra; Desai, Mahesh

    2011-09-01

    • To evaluate the results of miniperc vis-à-vis standard PNL in the treatment of stones of 1-2 cm in size. Miniperc may represent a reasonable procedure in patients with nonbulky urolithiasis offering a similar outcome as standard percutaneous nephrolithotomy (PNL) with advantage of reduced morbidity. • 55 procedures including 27 miniperc and 28 standard PNL were performed for renal stones 1-2 cm in size. Pediatric patient, active urinary tract infection, renal malformation, uncorrected coagulopathy and morbid obesity patients were excluded from the study. • The parameters studied were demography, operative time, postoperative analgesic requirement, hemoglobin drop, complications and stone clearance. • Mean tract size was 18.2 ± 2 F (15-20) and 26.8 ± 2 F (24-30), P value <0.0001 in the miniperc and standard PNL, respectively. Holmium LASER and pneumatic lithotripter were the main energy sources used in miniperc and standard PNL, respectively. • Miniperc operative time was longer than that of standard PNL (45.2 ± 12.6 vs 31 ± 16.6 min, P= 0.0008 respectively). • Conversely, there was an advantage of miniperc over standard PNL in terms of a significantly reduced hemoglobin drop (0.8 ± 0.9 vs 1.3 ± 0.4 gram%, P= 0.01), analgesic requirement (55.4 ± 50 vs 70.2 ± 52 mg tramadol, P= 0.29) and hospital stay (3.2 ± 0.8 vs 4.8 ± 0.6 days, P ≤ 0.001), respectively. • Intra- operative conversion of the procedure into a tubeless PNL was significantly more in the miniperc group (P ≤ 0.001). The miniperc and standard PNL group had clearance rates of 96% and 100%, respectively at 1 month follow up. • This study demonstrated significant advantages of the miniperc procedure in terms of reduced bleeding leading to a tubeless procedure and reduced hospital stay. • The stone free rates and the complications were similar in either group. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.

  4. Cleanup Verification Package for the 118-F-5 PNL Sawdust Pit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    L. D. Habel

    2008-05-20

    This cleanup verification package documents completion of remedial action, sampling activities, and compliance with cleanup criteria for the 118-F-5 Burial Ground, the PNL (Pacific Northwest Laboratory) Sawdust Pit. The 118-F-5 Burial Ground was an unlined trench that received radioactive sawdust from the floors of animal pens in the 100-F Experimental Animal Farm.

  5. The patient position for PNL: does it matter?

    PubMed

    Cracco, Cecilia Maria; Scoffone, Cesare Marco; Poggio, Massimiliano; Scarpa, Roberto Mario

    2010-03-01

    Currently, PNL is the treatment of choice for large and/or otherwise complex urolithiasis. PNL was initially performed with the patient in a supine-oblique position, but later on the prone position became the conventional one for habit and handiness. The prone position provides a larger area for percutaneous renal access, a wider space for instrument manipulation, and a claimed lower risk of splanchnic injury. Nonetheless, it implies important anaesthesiological risks, including circulatory, haemodynamic, and ventilatory difficulties; need of several nurses to be present for intraoperative changes of the decubitus in case of simultaneous retrograde instrumentation of the ureter, implying evident risks related to pressure points; an increased radiological hazard to the urologist's hands; patient discomfort. To overcome these drawbacks, various safe and effective changes in patient positioning for PNL have been proposed over the years, including the reverse lithotomy position, the prone split-leg position, the lateral decubitus, the supine position, and the Galdakao-modified supine Valdivia (GMSV) position. Among these, the GMSV position is safe and effective, and seems profitable and ergonomic. It allows optimal cardiopulmonary control during general anaesthesia; an easy puncture of the kidney; a reduced risk of colonic injury; simultaneous antero-retrograde approach to the renal cavities (PNL and retrograde ureteroscopy = ECIRS, Endoscopic Combined IntraRenal Surgery), with no need of intraoperative repositioning of the anaesthetized patient, less need for nurses in the operating room, less occupational risk due to shifting of heavy loads, less risk of pressure injuries related to inaccurate repositioning, and reduced duration of the procedure; facilitated spontaneous evacuation of stone fragments; a comfortable sitting position and a restrained X-ray exposure of the hands for the urologist. But, first of all, GMSV position fully supports a new comprehensive

  6. Two pectin lyase genes, pnl-1 and pnl-2, from Colletotrichum gloeosporioides f. sp. malvae differ in a cellulose-binding domain and in their expression during infection of Malva pusilla.

    PubMed

    Wei, Yangdou; Shih, Jenny; Li, Jieran; Goodwin, Paul H

    2002-07-01

    Two pectin lyase genes, designated pnl-1 and pnl-2, were cloned from Colletotrichum gloeosporioides f. sp. malvae, a pathogen of round-leaved mallow (Malva pusilla). pnl-1 was isolated using cDNA from infected plant material; pnl-2 was isolated using cDNA from 3-day-old mycelia grown in mallow-cell-wall extract (MCWE) broth. pnl-1 is the first pectinase gene described thus far to encode a cellulose-binding domain (CBD), which is common in cellulases and xylanases, whereas pnl-2 encodes a pectin lyase that lacks a CBD. In pure culture, pnl-1 expression could be detected when purified pectin or glucose was the sole carbon source, but not when MCWE was the sole carbon source. The lack of pnl-1 expression appeared to be due to gene repression by some unknown factor(s) in the cell-wall extract. In contrast, expression of pnl-2 was detected in cultures when MCWE, but not when purified pectin or glucose, was the sole carbon source. In infected tissue, detection of pnl-1 expression by Northern-blot hybridization and by RT-PCR began with the onset of the necrotrophic phase of infection. Expression ofpnl-2 was not detectable by Northern-blot hybridization, but was observed byRT-PCR in both the biotrophic and necrotrophic phases of infection. The differences between pnl-1 and pnl-2 (i.e. pnl-1 encoding a CBD and differences in the expression patterns of both genes) may be related to the requirements of C. gloeosporioides f. sp. malvae to be able to grow in host tissue under the different conditions present during the biotrophic and necrotrophic phases of infection.

  7. Day care PNL using 'Santosh-PGI hemostatic seal' versus standard PNL: A randomized controlled study.

    PubMed

    Kumar, Santosh; Singh, Shivanshu; Singh, Prashant; Singh, Shrawan Kumar

    2016-01-01

    To compare the outcomes of tubeless day care PNL using hemostatic seal in the access tract versus standard PNL. It was a prospective randomized controlled study. Cases were randomized to either the day care group with hemostatic seal (DCS) or the control group where patients were admitted and a nephrostomy tube was placed at the conclusion of surgery. A total of 180 cases were screened and out of these, 113 were included in the final analysis. The stone clearance rates were comparable in both the groups. The mean drop in hemoglobin was significantly lower in DCS group than the control group (1.05 ±0.68 vs. 1.30 ±0.58 gm/dl, p = 0.038).Mean postoperative pain score, analgesic requirement (paracetamol) and duration of hospital stay were also significantly lower in the DCS group (3.79 ±1.23 vs. 6.12 ±0.96, 1.48 ±0.50 vs. 4.09 ±1.11 grams and 0.48 ±0.26 vs. 4.74 ±1.53 days respectively; p <0.05). The incidence of urine leakage through the access tract site was significantly lower in the DCS subgroup when compared to the controls (3.6% vs. 21.1%, p <0.05). Cases in the DCS group resumed their normal activities in a significantly shorter time (8.05 ±3.05 vs.18.42 ±4.42 days; p <0.05). Higher proportion of cases in the DCS group got re-admitted, although it was not a statistically significant number (7.1% vs. 1.8%; p = 0.21). Tubeless day care PNL with composite hemostatic tract seal is considered safe. It resulted in a significant reduction of blood loss and analgesic requirement with significantly reduced hospital stay, nephrostomy tube site morbidity and time required to resume normal activity when compared to the standard PNL. However, patients must be compliant with the given instructions and should have access to a health care facility, as few of them may need re-admission.

  8. Day care PNL using ‘Santosh-PGI hemostatic seal’ versus standard PNL: A randomized controlled study

    PubMed Central

    Singh, Shivanshu; Singh, Prashant; Singh, Shrawan Kumar

    2016-01-01

    Introduction To compare the outcomes of tubeless day care PNL using hemostatic seal in the access tract versus standard PNL. Material and methods It was a prospective randomized controlled study. Cases were randomized to either the day care group with hemostatic seal (DCS) or the control group where patients were admitted and a nephrostomy tube was placed at the conclusion of surgery. Results A total of 180 cases were screened and out of these, 113 were included in the final analysis. The stone clearance rates were comparable in both the groups. The mean drop in hemoglobin was significantly lower in DCS group than the control group (1.05 ±0.68 vs. 1.30 ±0.58 gm/dl, p = 0.038).Mean postoperative pain score, analgesic requirement (paracetamol) and duration of hospital stay were also significantly lower in the DCS group (3.79 ±1.23 vs. 6.12 ±0.96, 1.48 ±0.50 vs. 4.09 ±1.11 grams and 0.48 ±0.26 vs. 4.74 ±1.53 days respectively; p <0.05). The incidence of urine leakage through the access tract site was significantly lower in the DCS subgroup when compared to the controls (3.6% vs. 21.1%, p <0.05). Cases in the DCS group resumed their normal activities in a significantly shorter time (8.05 ±3.05 vs.18.42 ±4.42 days; p <0.05). Higher proportion of cases in the DCS group got re-admitted, although it was not a statistically significant number (7.1% vs. 1.8%; p = 0.21). Conclusions Tubeless day care PNL with composite hemostatic tract seal is considered safe. It resulted in a significant reduction of blood loss and analgesic requirement with significantly reduced hospital stay, nephrostomy tube site morbidity and time required to resume normal activity when compared to the standard PNL. However, patients must be compliant with the given instructions and should have access to a health care facility, as few of them may need re-admission. PMID:27551557

  9. The effects of previous open renal stone surgery types on PNL outcomes

    PubMed Central

    Ozgor, Faruk; Kucuktopcu, Onur; Ucpinar, Burak; Sarilar, Omer; Erbin, Akif; Yanaral, Fatih; Sahan, Murat; Binbay, Murat

    2016-01-01

    Introduction: Our aim was to demonstrate the effect of insicion of renal parenchyma during open renal stone surgery (ORSS) on percutaneous nephrolithotomy (PNL) outcomes. Methods: Patients with history of ORSS who underwent PNL operation between June 2005 and June 2015 were analyzed retrospectively. Patients were divided into two groups according to their type of previous ORSS. Patients who had a history of ORSS with parenchymal insicion, such as radial nephrotomies, anatrophic nephrolithotomy, lower pole resection, and partial nephrectomy, were included in Group 1. Other patients with a history of open pyelolithotomy were enrolled in Group 2. Preoperative characteristics, perioperative data, stone-free status, and complications were compared between the groups. Stone-free status was defined as complete clearance of stone(s) or presence of residual fragments smaller than 4 mm. The retrospective nature of our study, different experience level of surgeons, and lack of the evaluation of anesthetic agents and cost of procedures were limitations of our study. Results: 123 and 111 patients were enrolled in Groups 1 and 2, respectively. Preoperative characteristics were similar between groups. In Group 1, the mean operative time was statistically longer than in Group 2 (p=0.013). Stone-free status was significantly higher in Group 2 than in Group 1 (p=0.027). Complication rates were similar between groups. Hemorrhage requiring blood transfusion was the most common complication in both groups (10.5% vs. 9.9%). Conclusions: Our study demonstrated that a history of previous ORSS with parenchymal insicion significantly reduces the success rates of PNL procedure. PMID:28255416

  10. The effects of previous open renal stone surgery types on PNL outcomes.

    PubMed

    Ozgor, Faruk; Kucuktopcu, Onur; Ucpinar, Burak; Sarilar, Omer; Erbin, Akif; Yanaral, Fatih; Sahan, Murat; Binbay, Murat

    2016-01-01

    Our aim was to demonstrate the effect of insicion of renal parenchyma during open renal stone surgery (ORSS) on percutaneous nephrolithotomy (PNL) outcomes. Patients with history of ORSS who underwent PNL operation between June 2005 and June 2015 were analyzed retrospectively. Patients were divided into two groups according to their type of previous ORSS. Patients who had a history of ORSS with parenchymal insicion, such as radial nephrotomies, anatrophic nephrolithotomy, lower pole resection, and partial nephrectomy, were included in Group 1. Other patients with a history of open pyelolithotomy were enrolled in Group 2. Preoperative characteristics, perioperative data, stone-free status, and complications were compared between the groups. Stone-free status was defined as complete clearance of stone(s) or presence of residual fragments smaller than 4 mm. The retrospective nature of our study, different experience level of surgeons, and lack of the evaluation of anesthetic agents and cost of procedures were limitations of our study. 123 and 111 patients were enrolled in Groups 1 and 2, respectively. Preoperative characteristics were similar between groups. In Group 1, the mean operative time was statistically longer than in Group 2 (p=0.013). Stone-free status was significantly higher in Group 2 than in Group 1 (p=0.027). Complication rates were similar between groups. Hemorrhage requiring blood transfusion was the most common complication in both groups (10.5% vs. 9.9%). Our study demonstrated that a history of previous ORSS with parenchymal insicion significantly reduces the success rates of PNL procedure.

  11. Supine or prone position for mini-PNL procedure: does it matter.

    PubMed

    Tokatlı, Zafer; Gokce, Mehmet Ilker; Süer, Evren; Sağlam, Remzi

    2015-06-01

    In this study it is aimed to compare the success and complication rates of mini-PNL procedure in supine and prone positions. In this retrospective study data of 180 patients treated with MPNL either in supine (n = 54) or prone (n = 126) positions between May 2009 and August 2014 was investigated. Success was defined as no visible stones >2 mm. Perioperative complications were classified using the modified Clavien system. Groups were compared with Chi square test or Student t test and for statistical significance p value of 0.05 was accepted. Mean age of the population was 42.5 ± 8.2 years and mean stone size was 23.9 ± 4.1 mm. The two groups were similar with regard to demographic characteristics and stone related characteristics except the ASA status. Success rates of the supine and prone groups were 85.1 and 87.3%, respectively (p = 0.701). No statistically significant differences in terms of complications were observed. Mean operative time was the only parameter different between the two groups (55 vs 82 min, p = 0.001). Supine position for PNL seems to be promising and the complication and success rates are shown to be similar to the prone position with MPNL technique. The only significant benefit of this technique is shorter operative time.

  12. Does the nephrostomy tract length impact the outcomes of percutaneous nephrolithotomy (PNL)?

    PubMed

    Astroza, Gaston M; Neisius, Andreas; Tsivian, Matvey; Wang, Agnes J; Preminger, Glenn M; Lipkin, Michael E

    2014-12-01

    Different factors can determine the outcomes of percutaneous nephrolithotomy (PNL). We analyzed the effect of tract length (TL) on outcomes after PNL. We performed a retrospective review of patients undergoing PNL between 2006 and 2011. Patients with preoperative computed tomography (CT), one percutaneous access tract and follow-up imaging within 3 months were included. TL was defined as distance between the skin to the calyx of puncture as measured on preoperative CT. Measurements were independently performed by two urologists and the average was used for analysis. Stone-free rate (SFR) was defined as zero fragments on follow-up imaging. Factors independently associated with the likelihood of being stone-free after PNL were determined using multivariable analysis adjusted for TL, location of access, the presence of incomplete or complete staghorn calculi and type of follow-up imaging. Complications (Clavien score) were independently assessed. A total of 222 patients were included. Median stone burden and body mass index (BMI) was 239.4 mm(2) and 30.5 [interquartile range (IQR): 25.7-36.2]. The median TL was 85.0 mm (IQR: 70.3-100.0) and highly correlated with BMI (ρ = 0.66, p < 0.001). A total of 101 patients (45.5 %) were stone-free. TL was not associated with SFR (p = 0.53). Clavien 1 and 2 complications occurred in 38 (17 %) while Clavien 3 and 4 complications occurred in 17 (8 %) patients. Multivariable analysis revealed no association between complications and TL even when adjusted for gender. Percutaneous TL is not associated with outcomes of PNL. PNL is a safe and effective treatment for stones in patients with differing body habitus.

  13. Flexible ureterorenoscopy versus miniaturized PNL for solitary renal calculi of 10-30 mm size.

    PubMed

    Knoll, Thomas; Jessen, Jan Peter; Honeck, Patrick; Wendt-Nordahl, Gunnar

    2011-12-01

    The value of flexible ureterorenoscopy (fURS) and miniaturized PNL (mPNL) for larger renal calculi is under discussion. This non-randomized prospective study aimed to evaluate fURS and mPNL for solitary renal stones of 10-30 mm size. fURS was carried out in 21 patients with last generation 7.5F endoscopes. Ureteral access sheaths were used in 19 patients. For mPNL, an 18F modified Amplatz sheath with a 14F nephroscope were used (n = 25). The procedure was performed either tubeless with an antegrade stent or a nephrostomy. Outcome and complications of both procedures were assessed. Patients' demographics and stone sizes were comparable (18 ± 5 vs. 19 ± 4 mm, P = 0.08). Patients in the fURS group had a higher mean BMI (31 vs. 27, P < 0.05). Total OR time was significantly longer for fURS (106 ± 51 vs. 59 ± 19 min., P < 0.001). More patients were stone-free after one single percutaneous treatment, while 2nd-stage treatments with fURS were common (total procedures 1.04 vs. 1.52, P < 0.001; immediate stone-free rate (SFR) 96% vs. 71.5%, P < 0.001). SFR after 4 weeks was 100% (mPNL) and 85.8% (fURS) (P < 0.01). Minor complications as classified by Clavien I or II occurred in 16 and 23.8%, mPNL and fURS, respectively, P = 0.13). No major complications (Clavien III-V) occured in both groups. Our series supports both the concept of either percutaneous or retrograde endoscopic treatment for renal calculi with both modalities offering excellent safety. However, while for fURS, a significantly higher rate of 2nd-stage procedures was necessary, and mPNL led to faster and higher SFR without increasing complication rate.

  14. Gene inactivation in the plant pathogen Glomerella cingulata: three strategies for the disruption of the pectin lyase gene pnlA.

    PubMed

    Bowen, J K; Templeton, M D; Sharrock, K R; Crowhurst, R N; Rikkerink, E H

    1995-01-20

    The feasibility of performing routine transformation-mediated mutagenesis in Glomerella cingulata was analysed by adopting three one-step gene disruption strategies targeted at the pectin lyase gene pnlA. The efficiencies of disruption following transformation with gene replacement- or gene truncation-disruption vectors were compared. To effect replacement-disruption, G. cingulata was transformed with a vector carrying DNA from the pnlA locus in which the majority of the coding sequence had been replaced by the gene for hygromycin B resistance. Two of the five transformants investigated contained an inactivated pnlA gene (pnlA-); both also contained ectopically integrated vector sequences. The efficacy of gene disruption by transformation with two gene truncation-disruption vectors was also assessed. Both vectors carried at 5' and 3' truncated copy of the pnlA coding sequence, adjacent to the gene for hygromycin B resistance. The promoter sequences controlling the selectable marker differed in the two vectors. In one vector the homologous G. cingulata gpdA promoter controlled hygromycin B phosphotransferase expression (homologous truncation vector), whereas in the second vector promoter elements were from the Aspergillus nidulans gpdA gene (heterologous truncation vector). Following transformation with the homologous truncation vector, nine transformants were analysed by Southern hybridisation; no transformants contained a disrupted pnlA gene. Of nineteen heterologous truncation vector transformants, three contained a disrupted pnlA gene; Southern analysis revealed single integrations of vector sequence at pnlA in two of these transformants. pnlA mRNA was not detected by Northern hybridisation in pnlA- transformants. pnlA- transformants failed to produce a PNLA protein with a pI identical to one normally detected in wild-type isolates by silver and activity staining of isoelectric focussing gels. Pathogenesis on Capsicum and apple was unaffected by disruption of

  15. Renal access in PNL under sonographic guidance: Do we really need to insert an open end ureteral catheter in dilated renal systems? A prospective randomized study.

    PubMed

    Eryildirim, Bilal; Tuncer, Murat; Camur, Emre; Ustun, Fatih; Tarhan, Fatih; Sarica, Kemal

    2017-10-03

    To evaluate the true necessity of open end ureteral catheter insertion in patients with moderate to severe pelvicalyceal system dilation treated with percutaneous nephrolithotomy (PNL) under sonographic guidance. 50 cases treated with PNL under sonographic guidance in prone position for solitary obstructing renal stones were evaluated. Patients were randomly divided into two groups; Group 1: Patients in whom a open end ureteral catheter was inserted prior to the procedure; Group 2: Patients receiving no catheter before PNL. In addition to the duration of the procedure as a whole and also all relevant stages as well, radiation exposure time, hospitalization period, mean nephrostomy tube duration, mean drop in Hb levels and all intra and postoperative complications have been evaluated. Mean size of the stones was 308.5 ± 133.2 mm2. Mean total duration of the PNL procedure in cases with open end ureteral catheter was significantly longer than the other cases (p < 0.001). Evaluation of the outcomes of the PNL procedures revealed no statistically significant difference between two groups regarding the stone-free rates (86% vs 84%). Additionally, there was no significant difference with respect to the duration of nephrostomy tube, hospitalization period and secondary procedures needed, complication rates as well as the post-operative Hb drop levels in both groups (p = 0.6830). Our results indicate that the placement of an open end ureteral catheter prior to a PNL procedure performed under sonographic access may not be indicated in selected cases presenting with solitary obstructing renal pelvic and/or calyceal stones.

  16. CRADA with United Solar Technologies and Pacific Northwest Laboratory (PNL-021): Thin film materialsfor low-cost high performance solar concentrators

    NASA Astrophysics Data System (ADS)

    Martin, P. M.; Affinito, J. D.; Gross, M. E.; Bennett, W. D.

    1995-03-01

    The objectives of this project were to develop and evaluate promising low-cost dielectric and polymer-protected thin-film reflective metal coatings to be applied to preformed continuously-curved solar reflector panels to enhance their solar reflectance, and to demonstrate protected solar reflective coatings on preformed solar concentrator panels. The opportunity for this project arose from a search by United Solar Technologies (UST) for organizations and facilities capable of applying reflective coatings to large preformed panels. PNL was identified as being uniquely qualified to participate in this collaborative project.

  17. 21 CFR 58.49 - Laboratory operation areas.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 1 2013-04-01 2013-04-01 false Laboratory operation areas. 58.49 Section 58.49... LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Facilities § 58.49 Laboratory operation areas... procedures required by nonclinical laboratory studies. [52 FR 33780, Sept. 4, 1987] ...

  18. 21 CFR 58.49 - Laboratory operation areas.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 1 2012-04-01 2012-04-01 false Laboratory operation areas. 58.49 Section 58.49... LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Facilities § 58.49 Laboratory operation areas... procedures required by nonclinical laboratory studies. [52 FR 33780, Sept. 4, 1987] ...

  19. 21 CFR 58.49 - Laboratory operation areas.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 1 2011-04-01 2011-04-01 false Laboratory operation areas. 58.49 Section 58.49... LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Facilities § 58.49 Laboratory operation areas... procedures required by nonclinical laboratory studies. [52 FR 33780, Sept. 4, 1987] ...

  20. 21 CFR 58.49 - Laboratory operation areas.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Laboratory operation areas. 58.49 Section 58.49... LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Facilities § 58.49 Laboratory operation areas. Separate laboratory space shall be provided, as needed, for the performance of the routine and specialized...

  1. 40 CFR 160.49 - Laboratory operation areas.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Laboratory operation areas. 160.49 Section 160.49 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Facilities § 160.49 Laboratory operation areas. Separate laboratory...

  2. 40 CFR 160.49 - Laboratory operation areas.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 24 2011-07-01 2011-07-01 false Laboratory operation areas. 160.49 Section 160.49 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Facilities § 160.49 Laboratory operation areas. Separate laboratory...

  3. 40 CFR 792.49 - Laboratory operation areas.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 32 2011-07-01 2011-07-01 false Laboratory operation areas. 792.49... CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Facilities § 792.49 Laboratory operation areas. Separate laboratory space and other space shall be provided, as needed, for the performance of the routine...

  4. 40 CFR 792.49 - Laboratory operation areas.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Laboratory operation areas. 792.49 Section 792.49 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Facilities § 792.49 Laboratory operation areas...

  5. Pacific Northwest Laboratory annual report for 1980 to the DOE Assistant Secretary for Environment. Part 5. Environmental assessment, control, health and safety

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baalman, R.W.; Hays, I.D.

    1981-02-01

    Pacific Northwest Laboratory's (PNL) 1980 annual report to the DOE Assistant Secretary for Environment describes research in environment, health, and safety conducted during fiscal year 1980. Part 5 includes technology assessments for natural gas, enhanced oil recovery, oil shale, uranium mining, magnetic fusion energy, solar energy, uranium enrichment and industrial energy utilization; regional analysis studies of environmental transport and community impacts; environmental and safety engineering for LNG, oil spills, LPG, shale oil waste waters, geothermal liquid waste disposal, compressed air energy storage, and nuclear/fusion fuel cycles; operational and environmental safety studies of decommissioning, environmental monitoring, personnel dosimetry, and analysis ofmore » criticality safety; health physics studies; and epidemiological studies. Also included are an author index, organization of PNL charts and distribution lists of the annual report, along with lists of presentations and publications. (DLS)« less

  6. KBA62 and PNL2: 2 new melanoma markers-immunohistochemical analysis of 1563 tumors including metastatic, desmoplastic, and mucosal melanomas and their mimics.

    PubMed

    Aung, Phyu Phyu; Sarlomo-Rikala, Maarit; Lasota, Jerzy; Lai, Jin-Ping; Wang, Zeng-Feng; Miettinen, Markku

    2012-02-01

    Identification of metastatic melanoma can be difficult because of its considerable morphologic variation and mimicry of a wide variety of other tumors. The more melanoma-specific melanoma markers, MelanA/MART-1, HMB45, and tyrosinase, used in addition to S100 protein, all have limitations in sensitivity and specificity. In this study, we evaluated 2 new melanoma markers, monoclonal antibodies KBA62 and PNL2 to yet unidentified antigens, using a large panel of metastatic melanomas (n=214), desmoplastic melanomas (n=34), gastrointestinal mucosal melanomas (n=54), benign nevi (n=27), clear cell sarcomas (n=16), and nonmelanocytic tumors (n=1218). Immunoreactivity for KBA62 and PNL2 was found in all pigmented nevi and in 86% and 90% of metastatic melanomas, respectively. Mucosal melanomas showed a similar rate of PNL2 immunoreactivity but somewhat less frequent KBA62 positivity (72%). In addition, KBA62 was found to be a sensitive diagnostic marker for desmoplastic melanoma (28 of 34; 82%), whereas PNL2 was only rarely positive (2 of 34; 6%). KBA62-positive normal tissues included pericytes, vascular and parenchymal smooth muscles, and basal cells of complex epithelia, including myoepithelia, whereas PNL2 labeled only melanocytes and neutrophils. Among nonmelanocytic tumors, those that were KBA62 positive were nodular fasciitis, leiomyoma and leiomyosarcoma, gastrointestinal stromal tumors, benign and malignant nerve sheath tumors, synovial sarcoma, and subsets of various carcinomas, especially those with squamous cell/stratified epithelial differentiation. PNL2 positivity in nonmelanocytic tumors was more restricted but occurred consistently in angiomyolipoma and other perivascular epitheloid cell tumor and in chronic myeloid leukemia tissue infiltrates. KBA62 may assist in the identification of desmoplastic melanomas, but its widespread occurrence in nonmelanomas limits utility. PNL2 is highly specific for melanomas but lacks reactivity with desmoplastic melanomas

  7. The effect of Pro NanoLipospheres (PNL) formulation containing natural absorption enhancers on the oral bioavailability of delta-9-tetrahydrocannabinol (THC) and cannabidiol (CBD) in a rat model.

    PubMed

    Cherniakov, Irina; Izgelov, Dvora; Domb, Abraham J; Hoffman, Amnon

    2017-11-15

    The lipophilic phytocannabinoids cannabidiol (CBD) and Δ 9 -tetrahydrocannabinol (THC) show therapeutic efficacy in various medical conditions. Both molecules are poorly water soluble and subjected to extensive first pass metabolism in the gastrointestinal tract, leading to a limited oral bioavailability of approximately 9%. We have developed an advanced lipid based Self-Emulsifying Drug Delivery System termed Advanced Pro-NanoLiposphere (PNL) pre-concentrate. The PNL is composed of lipid and emulsifying excipients of GRAS status and are known to increase solubility and reduce Phase I metabolism of lipophilic active compounds. Advanced PNLs are PNLs with an incorporated natural absorption enhancers. These molecules are natural alkaloids and phenolic compounds which were reported to inhibit certain phase I and phase II metabolism processes. Here we use piperine, curcumin and resveratrol to formulate the Advanced-PNL formulations. Consequently, we have explored the utility of these Advanced-PNLs on CBD and THC oral bioavailability. Oral administration of CBD-piperine-PNL resulted in 6-fold increase in AUC compared to CBD solution, proving to be the most effective of the screened formulations. The same trend was found in pharmacokinetic experiments of THC-piperine-PNL which resulted in a 9.3-fold increase in AUC as compared to THC solution. Our Piperine-PNL can be used as a platform for synchronized delivery of piperine and CBD or THC to the enterocyte site. This co-localization provides an increase in CBD and THC bioavailability by its effect at the pre-enterocyte and the enterocyte levels of the absorption process. The extra augmentation in the absorption of CBD and THC by incorporating piperine into PNL is attributed to the inhibition of Phase I and phase II metabolism by piperine in addition to the Phase I metabolism and P-gp inhibition by PNL. These novel results pave the way to utilize piperine-PNL delivery system for other poorly soluble, highly metabolized

  8. Pacific Northwest Laboratory Institutional Plan FY 1995-2000

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-12-01

    This report serves as a document to describe the role PNL is positioned to take in the Department of Energy`s plans for its national centers in the period 1995-2000. It highlights the strengths of the facilities and personnel present at the laboratory, touches on the accomplishments and projects they have contributed to, and the direction being taken to prepare for the demands to be placed on DOE facilities in the near and far term. It consists of sections titled: director`s statement; laboratory mission and core competencies; laboratory strategic plan; laboratory initiatives; core business areas; critical success factors.

  9. The pnk/pnl gene (ORF 86) of Autographa californica nucleopolyhedrovirus is a non-essential, immediate early gene.

    PubMed

    Durantel, D; Croizier, L; Ayres, M D; Croizier, G; Possee, R D; López-Ferber, M

    1998-03-01

    Autographa californica nucleopolyhedrovirus (AcMNPV) ORF 86, located within the HindIII C fragment, potentially encodes a protein which shares sequence similarity with two T4 bacteriophage gene products, RNA ligase and polynucleotide kinase. This AcMNPV gene has been designated pnk/pnl but has yet to be assigned a function in virus replication. It has been classified as an immediate early virus gene, since the promoter was active in uninfected insect cells and mRNA transcripts were detectable from 4 to 48 h post-infection and in the presence of cycloheximide or aphidicolin in virus-infected cells. The extremities of the transcript have been mapped by primer extension and 3' RACE-PCR to positions -18 from the translational start codon and +15 downstream of the stop codon. The function of pnk/pnl was investigated by producing a recombinant virus (Acdel86lacZ) with the coding region replaced with that of lacZ. This virus replicated normally in Spodoptera frugiperda (Sf 21) cells, indicating that pnk/pnl is not essential for propagation in these cells. Virus protein production in Acdel86lacZ-infected Sf 21 cells also appeared to be unaffected, with normal synthesis of the IE-1, GP64, VP39 and polyhedrin proteins. Shut-down of host protein synthesis was not abolished in recombinant infection. When other baculovirus genomes were examined for the presence of pnk/pnl by restriction enzyme digestion and PCR, a deletion was found in AcMNPV 1.2, Galleria mellonella NPV (GmMNPV) and Bombyx mori NPV (BmNPV), suggesting that in many isolates this gene has either never been acquired or has been lost during genome evolution. This is one of the first baculovirus immediate early genes that appears to be nonessential for virus survival.

  10. Annotated bibliography of radioactive waste management publications at Pacific Northwest Laboratory, January 1978 through July 1982. [831 abstracts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1982-09-01

    This bibliography lists publications (831 abstracts) from the Pacific Northwest Laboratory's Department of Energy sponsored research and development programs from January 1978 through July of 1982. The abstracts are grouped in subject categories, as shown in the table of contents. Entries in the subject index also facilitate access by subject, e.g., High-Level Radioactive Wastes. Three indexes, each preceded by a brief description, are provided: personal author, subject, and report number. Cited are research reports, journal articles, books, patents, theses, and conference papers. Excluded are technical progress reports. Since 1978 the Nuclear Waste Management Quarterly Progress Report has been published undermore » the series number PNL-3000. Beginning in 1982, this publication has been issued semiannually, under the series number PNL-4250. This bibliography is the successor to two others, BNWL-2201 (covering the years 1965-1976) and PNL-4050 (1975-1978). It is intended to provide a useful reference to literature in waste management written or compiled by PNL staff.« less

  11. Bobi A. Garrett - Deputy Laboratory Director and Chief Operating Officer

    Science.gov Websites

    | NREL Bobi A. Garrett - Deputy Laboratory Director and Chief Operating Officer Bobi A. Garrett - Deputy Laboratory Director and Chief Operating Officer A photo of Bobi A. Garrett, Deputy Laboratory Director and Chief Operating Officer In her role as deputy laboratory director/chief operating officer (COO

  12. Estimates of emergency operating capacity in US manufacturing and nonmanufacturing industries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belzer, D.B.; Serot, D.E.; Kellogg, M.A.

    1991-03-01

    Development of integrated mobilization preparedness policies requires planning estimates of available productive capacity during national emergency conditions. Such estimates must be developed in a manner that allows evaluation of current trends in capacity and the consideration of uncertainties in various data inputs and in engineering assumptions. This study, conducted by Pacific Northwest Laboratory (PNL), developed estimates of emergency operating capacity (EOC) for 446 manufacturing industries at the 4-digit Standard Industrial Classification (SIC) level of aggregation and for 24 key non-manufacturing sectors. This volume presents tabular and graphical results of the historical analysis and projections for each SIC industry. (JF)

  13. Treatment of small lower pole calculi--SWL vs. URS vs. PNL?

    PubMed

    Knoll, Thomas; Tasca, Andrea; Buchholz, Noor P

    2011-03-01

    According to current guideline recommendations extracorporeal shock wave lithotripsy (SWL) remains the first choice treatment for small and mid-sized renal calculi. However, the results of SWL treatment for lower pole stones can be disappointing whilst more invasive endoscopic modalities, such as flexible ureterorenoscopy (fURS) and percutaneous nephrolithotomy (PNL) are often considered more effective. This article summarizes a point-counterpoint discussion at the 9th eULIS symposium in Como, Italy, and discusses the potential advantages and disadvantages of the different therapeutic approaches.

  14. Validation of a novel cost effective easy to produce and durable in vitro model for kidney-puncture and PNL-Simulation.

    PubMed

    Klein, Jan Thorsten; Rassweiler, Jens; Rassweiler-Seyfried, Marie-Claire Charlotte

    2018-03-29

    Nephrolithiasis is one of the most common diseases in urology. According to the EAU Guidelines, a percutaneous nephrolitholapaxy (PNL) is recommended when treating a kidney stone >2 cm. Nowadays PNL is performed even for smaller stones (<1 cm) using miniaturized instruments. The most challenging part of any PNL is the puncture of the planned site. PNL-novice surgeons need to practice this step in a safe environment with an ideal training model. We developed and evaluated a new, easy to produce, in-vitro model for the training of the freehand puncture of the kidney. Porcine kidneys with ureters were embedded in ballistic gel. Food coloring and preservative agent were added. We used the standard imaging modalities of X-ray and ultrasound to validate the training model. An additional new technique, the iPAD guided puncture, was evaluated. Five novices and three experts conducted 12 punctures for each imaging technique. Puncture time, radiation dose, and number of attempts to a successful puncture were measured. Mann-Whitney-U, Kruskal-Wallis, and U-Tests were used for statistical analyses. The sonographic guided puncture is slightly but not significantly faster than the fluoroscopic guided puncture and the iPAD assisted puncture. Similarly, the most experienced surgeon's time for a successful puncture was slightly less than that of the residents, and the experienced surgeons needed the least attempts to perform a successful puncture. In terms of radiation exposure, the residents had a significant reduction of radiation exposure compared to the experienced surgeons. The newly developed ballistic gel kidney-puncture model is a good training tool for a variety of kidney puncture techniques, with good content, construct, and face validity.

  15. 21 CFR 111.110 - What quality control operations are required for laboratory operations associated with the...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... laboratory operations associated with the production and process control system? 111.110 Section 111.110 Food... OPERATIONS FOR DIETARY SUPPLEMENTS Production and Process Control System: Requirements for Quality Control... production and process control system? Quality control operations for laboratory operations associated with...

  16. Hanford Laboratories Operation monthly activities report, August 1959

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1959-09-15

    This is the monthly report for the Hanford Laboratories Operation, August, 1959. Reactor fuels, chemistry, dosimetry, separation processes, reactor technology financial activities, visits, biology operation, physics and instrumentation research, employee relations, and operations research and synthesis operation are discussed.

  17. Hanford Laboratories Operation monthly activities report, September 1961

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1961-10-16

    This is the monthly report for the Hanford Laboratories Operation September 1961. Reactor fuels, chemistry, dosimetry, separation processes, reactor technology, financial activities, biology operation, physics and instrumentation research, operations research and synthesis, programming, and radiation protection operation are discussed.

  18. Environmental Engineering Unit Operations and Unit Processes Laboratory Manual.

    ERIC Educational Resources Information Center

    O'Connor, John T., Ed.

    This manual was prepared for the purpose of stimulating the development of effective unit operations and unit processes laboratory courses in environmental engineering. Laboratory activities emphasizing physical operations, biological, and chemical processes are designed for various educational and equipment levels. An introductory section reviews…

  19. Sequence of pNL194, a 79.3-Kilobase IncN Plasmid Carrying the blaVIM-1 Metallo-β-Lactamase Gene in Klebsiella pneumoniae▿

    PubMed Central

    Miriagou, V.; Papagiannitsis, C. C.; Kotsakis, S. D.; Loli, A.; Tzelepi, E.; Legakis, N. J.; Tzouvelekis, L. S.

    2010-01-01

    The nucleotide sequence of pNL194, a VIM-1-encoding plasmid, is described in this study. pNL194 (79,307 bp) comprised an IncN-characteristic segment (38,940 bp) and a mosaic structure (40,367 bp) including blaVIM-1, aacA7, aadA1, aadA2, dfrA1, dfrA12, aphA1, strA, strB, and sul1. Tn1000 or Tn5501 insertion within fipA probably facilitated recruitment of additional mobile elements carrying resistance genes. PMID:20660690

  20. Hanford Internal Dosimetry Program Manual, PNL-MA-552

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carbaugh, Eugene H.; Bihl, Donald E.; Maclellan, Jay A.

    2009-09-24

    This manual is a guide to the services provided by the Hanford Internal Dosimetry Program (IDP), which is operated by the Pacific Northwest National Laboratory.( ) for the U.S. Department of Energy Richland Operations Office, Office of River Protection and their Hanford Site contractors. The manual describes the roles of and relationships between the IDP and the radiation protection programs of the Hanford Site contractors. Recommendations and guidance are also provided for consideration in implementing bioassay monitoring and internal dosimetry elements of radiation protection programs.

  1. Hanford Laboratories Operation monthly activities report, September 1960

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1960-10-15

    This is the monthly report for the Hanford Laboratories Operation, October, 1960. Metallurgy, reactor fuels, chemistry, dosimetry, separation processes, reactor technology, financial activities, visits, biology operation, physics and instrumentation research, and employee relations are discussed.

  2. Hanford Laboratories Operation monthly activities report, November 1962

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1962-12-14

    This is the monthly report for the Hanford Laboratories Operation, November 1962. Metallurgy, reactor fuels, chemistry, dosimetry, separation processes, reactor technology, financial activities, visits, biology operation, physics and instrumentation research, and employee relations are discussed.

  3. Laboratory Information Systems Management and Operations.

    PubMed

    Cucoranu, Ioan C

    2015-06-01

    The main mission of a laboratory information system (LIS) is to manage workflow and deliver accurate results for clinical management. Successful selection and implementation of an anatomic pathology LIS is not complete unless it is complemented by specialized information technology support and maintenance. LIS is required to remain continuously operational with minimal or no downtime and the LIS team has to ensure that all operations are compliant with the mandated rules and regulations. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Pressure Swing Adsorption in the Unit Operations Laboratory

    ERIC Educational Resources Information Center

    Ganley, Jason

    2018-01-01

    This paper describes a student laboratory in the Unit Operations Laboratory at the Colorado School of Mines: air separation by pressure swing adsorption. The flexibility of the system enables students to study the production of enriched nitrogen or oxygen streams. Automatic data acquisition permits the study of cycle steps and performance.…

  5. Saxton Transportation Operations Laboratory : driving future highways

    DOT National Transportation Integrated Search

    2017-01-01

    The Saxton Laboratory is supplementing the Office of Operations R&Ds connected automation research program, which includes an initial focus on applications that use longitudinal control, with active driver engagement and advisory information, to i...

  6. 48 CFR 970.1504-1-3 - Special considerations: Laboratory management and operation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...: Laboratory management and operation. 970.1504-1-3 Section 970.1504-1-3 Federal Acquisition Regulations System DEPARTMENT OF ENERGY AGENCY SUPPLEMENTARY REGULATIONS DOE MANAGEMENT AND OPERATING CONTRACTS Contracting by Negotiation 970.1504-1-3 Special considerations: Laboratory management and operation. (a) For the management...

  7. Pacific Northwest Laboratory annual report for 1992 to the DOE Office of Energy Research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grove, L.K.

    1993-03-01

    The 1992 Annual Report from Pacific Northwest Laboratory (PNL) to the US Department of Energy (DOE) describes research in environment and health conducted during fiscal year 1992. This report consists of four volumes oriented to particular segments of the PNL program, describing research performed for the DOE Office of Health and Environmental Research in the Office of Energy Research. The parts of the 1992 Annual Report are: Biomedical Sciences; Environmental Sciences; Atmospheric Sciences; and Physical Sciences. This Report is Part II: Environmental Sciences. Included in this report are developments in Subsurface Science, Terrestrial Science, Laboratory-Directed Research and Development, Interactions withmore » Educational Institutions, Technology Transfer, Publications, and Presentations. The research is directed toward developing a fundamental understanding of subsurface and terrestrial systems as a basis for both managing these critical resources and addressing environmental problems such as environmental restoration and global change. The Technology Transfer section of this report describes a number of examples in which fundamental research is laying the groundwork for the technology needed to resolve important environmental problems. The Interactions with Educational Institutions section of the report illustrates the results of a long-term, proactive program to make PNL facilities available for university and preuniversity education and to involve educational institutions in research programs. The areas under investigation include the effect of geochemical and physical phenomena on the diversity and function of microorganisms in deep subsurface environments, ways to address subsurface heterogeneity, and ways to determine the key biochemical and physiological pathways (and DNA markers) that control nutrient, water, and energy dynamics in arid ecosystems and the response of these systems to disturbance and climatic change.« less

  8. Incorporating Safety into a Unit Operations Laboratory Course.

    ERIC Educational Resources Information Center

    King, Julia A.

    1998-01-01

    Details the incorporation of safety procedures and issues into the curriculum of an undergraduate chemical engineering unit operations laboratory course. Includes checklists and sample reporting forms. (DDR)

  9. Pacific Northwest Laboratory annual report for 1990 to the DOE Office of Energy Research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, J.F.

    This report summarizes progress on OHER human health, biological, and general life sciences research programs conducted at PNL in FY 1990. The research develops the knowledge and scientific principles necessary to identify understand, and anticipate the long-term health consequences of energy-related radiation and chemicals. Our continuing emphasis is to decrease the uncertainty of health risk estimates from existing and developing energy-related technologies through an increased of understanding of how radiation and chemicals cause biological damage. The sequence of this report of PNL research reflects the OHER programmatic structure. The first section, on human health research, concerns epidemiological and statistical studiesmore » for assessing health risks. The next section contains reports of biological research in laboratory animals and in vitro cell systems, including research with radionuclides and chemicals. The general life sciences research section reports research conducted for the OHER human genome research program.« less

  10. Lewis Wooten, manager of the Mission Operations Laboratory

    NASA Image and Video Library

    2015-07-20

    LEWIS WOOTEN MANAGES THE MISSION OPERATIONS LABORATORY. MORE THAN 1600 INVESTIGATIONS AND STUDENT EXPERIMENTS FOR OVER 80 COUNTRIES HAVE BEEN COMPLETED WITH THE HELP OF WOOTEN'S TEAM AT NASA'S MARSHALL SPACE FLIGHT CENTER IN HUNTSVILLE, ALABAMA.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The Pacific Northwest Laboratory (PNL), operated by Battelle Memorial Institute under contract to the U.S. Department of Energy, operates tank systems for the U.S. Department of Energy, Richland Operations Office (DOE-RL), that contain dangerous waste constituents as defined by Washington State Department of Ecology (WDOE) Dangerous Waste Regulations, Washington Administrative Code (WAC) 173-303-040(18). Chapter 173-303-640(2) of the WAC requires the performance of integrity assessments for each existing tank system that treats or stores dangerous waste, except those operating under interim status with compliant secondary containment. This Integrity Assessment Plan (IAP) identifies all tasks that will be performed during the integritymore » assessment of the PNL-operated Radioactive Liquid Waste Systems (RLWS) associated with the 324 and 325 Buildings located in the 300 Area of the Hanford Site. It describes the inspections, tests, and analyses required to assess the integrity of the PNL RLWS (tanks, ancillary equipment, and secondary containment) and provides sufficient information for adequate budgeting and control of the assessment program. It also provides necessary information to permit the Independent, Qualified, Registered Professional Engineer (IQRPE) to approve the integrity assessment program.« less

  12. Mars Science Laboratory Cruise Propulsion Maneuvering Operations

    NASA Technical Reports Server (NTRS)

    Baker, Raymond S.; Mizukami, Masahi; Barber, Todd J.

    2013-01-01

    Mars Science Laboratory "Curiosity" is NASA's most recent mission to Mars, launched in November 2011, and landed in August 2012. It is a subcompact car-sized nuclear powered rover designed for a long duration mission, with an extensive suite of science instruments. Entry, descent and landing used a unique "skycrane" concept. This report describes the propulsive maneuvering operations during cruise from Earth to Mars, to control attitudes and to target the vehicle for entry. The propulsion subsystem, mission operations, and flight performance are discussed. All trajectory control maneuvers were well within accuracy requirements, and all turns and spin corrections were nominal.

  13. Pacific Northwest Laboratory annual report for 1992 to the DOE Office of Energy Research. Part 2, Environmental sciences

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grove, L.K.; Wildung, R.E.

    1993-03-01

    The 1992 Annual Report from Pacific Northwest Laboratory (PNL) to the US Department of Energy (DOE) describes research in environment and health conducted during fiscal year 1992. This report consists of four volumes oriented to particular segments of the PNL program, describing research performed for the DOE Office of Health and Environmental Research in the Office of Energy Research. The parts of the 1992 Annual Report are: Biomedical Sciences; Environmental Sciences; Atmospheric Sciences; and Physical Sciences. This Report is Part 2: Environmental Sciences. Included in this report are developments in Subsurface Science, Terrestrial Science, Laboratory-Directed Research and Development, Interactions withmore » Educational Institutions, Technology Transfer, Publications, and Presentations. The research is directed toward developing a fundamental understanding of subsurface and terrestrial systems as a basis for both managing these critical resources and addressing environmental problems such as environmental restoration and global change. The Technology Transfer section of this report describes a number of examples in which fundamental research is laying the groundwork for the technology needed to resolve important environmental problems. The Interactions with Educational Institutions section of the report illustrates the results of a long-term, proactive program to make PNL facilities available for university and preuniversity education and to involve educational institutions in research programs. The areas under investigation include the effect of geochemical and physical phenomena on the diversity and function of microorganisms in deep subsurface environments, ways to address subsurface heterogeneity, and ways to determine the key biochemical and physiological pathways (and DNA markers) that control nutrient, water, and energy dynamics in arid ecosystems and the response of these systems to disturbance and climatic change.« less

  14. Slurry spray distribution within a simulated laboratory scale spray dryer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bertone, P.C.

    1979-12-20

    It was found that the distribution of liquid striking the sides of a simulated room temperature spray dryer was not significantly altered by the choice of nozles, nor by a variation in nozzle operating conditions. Instead, it was found to be a function of the spray dryer's configuration. A cocurrent flow of air down the drying cylinder, not possible with PNL's closed top, favorably altered the spray distribution by both decreasing the amount of liquid striking the interior of the cylinder from 72 to 26% of the feed supplied, and by shifting the zone of maximum impact from 1.0 tomore » 1.7 feet from the nozzle. These findings led to the redesign of the laboratory scale spray dryer to be tested at the Savannah River Plant. The diameter of the drying chamber was increased from 5 to 8 inches, and a cocurrent flow of air was established with a closed recycle. Finally, this investigation suggested a drying scheme which offers all the advantages of spray drying without many of its limitations.« less

  15. The manned space-laboratories control centre - MSCC. Operational functions and its implementation

    NASA Astrophysics Data System (ADS)

    Brogl, H.; Kehr, J.; Wlaka, M.

    This paper describes the functions of the MSCC during the operations of the Columbus Attached Laboratory and the Free Flying Laboratory as part of the In-Orbit-Infrastructure Ground Segment. For the Attached Laboratory, MSCC payload operations coordination for European experiments within the Attached Laboratory and elsewhere on the Space Station Freedom will be explained. The Free Flying Laboratory will be operated and maintained exclusively from the MSCC during its 30 years lifetime. Several operational scenarios will demonstrate the role of the MSCC during routine - and servicing operations: of main importance are the servicing activities of the Attached Laboratory and the Free Flyer at the Space Station as well as servicing of the Free Flyer by the European Space Plane Hermes. The MSCC will have complex operational-, communications-and management interfaces with the IOI Ground Segment, the Space Station User community and with the international partners. Columbus User Support Centres will be established in many European member states, which have to be coordinated by the MSCC to ensure the proper reception of the scientific data and to provide them with quick access to their experiments in space. For operations planning and execution of experiments in the Attached Laboratory, a close cooperation with the Space Station control authorities in the USA will be established. The paper will show the development of the MSCC being initially used for the upcoming Spacelab Mission D-2 (MSCC Phase-1) and later upgraded to a Columbus dedicated control centre (MSCC Phase-2). For the initial construction phase the establishing of MSCC requirements, the philosophie used for the definition of the 'basic infrastructure' and key features of the installed facilities will be addressed. Resulting from Columbus and D-2 requirements, the sizing of the building with respect to controlrooms, conference rooms, office spare and simulation high-bay areas will be discussed. The defined 'basic

  16. The NUITM-KEMRI P3 Laboratory in Kenya: Establishment, Features, Operation and Maintenance

    PubMed Central

    Inoue, Shingo; Wandera, Ernest; Miringu, Gabriel; Bundi, Martin; Narita, Chika; Ashur, Salame; Kwallah, Allan; Galata, Amina; Abubakar, Mwajuma; Suka, Sora; Mohamed, Shah; Karama, Mohamed; Horio, Masahiro; Shimada, Masaaki; Ichinose, Yoshio

    2013-01-01

    A biocontainment facility is a core component in any research setting due to the services it renders towards comprehensive biosafety observance. The NUITM-KEMRI P3 facility was set up in 2007 and has been actively in use since 2010 by researchers from this and other institutions. A number of hazardous agents have been handled in the laboratory among them MDR-TB and yellow fever viruses. The laboratory has the general physical and operational features of a P3 laboratory in addition to a number of unique features, among them the water-air filtration system, the eco-mode operation feature and automation of the pressure system that make the facility more efficient. It is equipped with biosafety and emergency response equipments alongside common laboratory equipments, maintained regularly using daily, monthly and yearly routines. Security and safety is strictly observed within the facility, enhanced by restricted entry, strict documentation and use of safety symbols. Training is also engrained within the operation of the laboratory and is undertaken and evaluated annually. Though the laboratory is in the process of obtaining accreditation, it is fully certified courtesy of the manufactures’ and constructed within specified standards. PMID:23533023

  17. Designing Mission Operations for the Gravity Recovery and Interior Laboratory Mission

    NASA Technical Reports Server (NTRS)

    Havens, Glen G.; Beerer, Joseph G.

    2012-01-01

    NASA's Gravity Recovery and Interior Laboratory (GRAIL) mission, to understand the internal structure and thermal evolution of the Moon, offered unique challenges to mission operations. From launch through end of mission, the twin GRAIL orbiters had to be operated in parallel. The journey to the Moon and into the low science orbit involved numerous maneuvers, planned on tight timelines, to ultimately place the orbiters into the required formation-flying configuration necessary. The baseline GRAIL mission is short, only 9 months in duration, but progressed quickly through seven very unique mission phases. Compressed into this short mission timeline, operations activities and maneuvers for both orbiters had to be planned and coordinated carefully. To prepare for these challenges, development of the GRAIL Mission Operations System began in 2008. Based on high heritage multi-mission operations developed by NASA's Jet Propulsion Laboratory and Lockheed Martin, the GRAIL mission operations system was adapted to meet the unique challenges posed by the GRAIL mission design. This paper describes GRAIL's system engineering development process for defining GRAIL's operations scenarios and generating requirements, tracing the evolution from operations concept through final design, implementation, and validation.

  18. An exploratory investigation of the translation of Pacific Northwest Laboratory`s print manuals system to an on-line manuals system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heubach, J.G.; Hunt, S.T.; Pond, L.R.

    1992-06-01

    Information management technology has proliferated in the past decade in response to the information explosion. As documentation accumulates, the need to access information residing in manuals, handbooks and regulations conveniently, accurately, and quickly has increased. However, studies show that only fractions of the available information is read (Martin, 1978). Consequently, one of the biggest challenges in linking information and electronic management of information is to use the power of communication technology to meet the information needs of the audience. Pacific Northwest Laboratories` (PNL) investigation of translating its print manual system to an on-line system fits this challenge precisely. PNL`s manualsmore » contain a tremendous amount of information for which manual holders are responsible. To perform their tasks in compliance with policy and procedure guidelines, users need to access information accurately, conveniently, and quickly. In order to select and use information management tools wisely, answers must be sought to a few basic questions. Communication experts cite four key questions: What do users want? What do users need? What characteristics of an on-line information system affect its usefulness? Who are the users whose wants and needs are to be met? Once these questions are answered, attention can be focused on finding the best match between user requirements and technology characteristics and weighing the costs and benefits of proposed options.« less

  19. Histopathological examination of nerve samples from pure neural leprosy patients: obtaining maximum information to improve diagnostic efficiency.

    PubMed

    Antunes, Sérgio Luiz Gomes; Chimelli, Leila; Jardim, Márcia Rodrigues; Vital, Robson Teixeira; Nery, José Augusto da Costa; Corte-Real, Suzana; Hacker, Mariana Andréa Vilas Boas; Sarno, Euzenir Nunes

    2012-03-01

    Nerve biopsy examination is an important auxiliary procedure for diagnosing pure neural leprosy (PNL). When acid-fast bacilli (AFB) are not detected in the nerve sample, the value of other nonspecific histological alterations should be considered along with pertinent clinical, electroneuromyographical and laboratory data (the detection of Mycobacterium leprae DNA with polymerase chain reaction and the detection of serum anti-phenolic glycolipid 1 antibodies) to support a possible or probable PNL diagnosis. Three hundred forty nerve samples [144 from PNL patients and 196 from patients with non-leprosy peripheral neuropathies (NLN)] were examined. Both AFB-negative and AFB-positive PNL samples had more frequent histopathological alterations (epithelioid granulomas, mononuclear infiltrates, fibrosis, perineurial and subperineurial oedema and decreased numbers of myelinated fibres) than the NLN group. Multivariate analysis revealed that independently, mononuclear infiltrate and perineurial fibrosis were more common in the PNL group and were able to correctly classify AFB-negative PNL samples. These results indicate that even in the absence of AFB, these histopathological nerve alterations may justify a PNL diagnosis when observed in conjunction with pertinent clinical, epidemiological and laboratory data.

  20. From the Research Laboratory to the Operating Company: How Information Travels.

    ERIC Educational Resources Information Center

    Coppin, Ann S.; Palmer, Linda L.

    1980-01-01

    Reviews transmission processes of Chevron Oil Field Research Company (COFRC) research results from laboratories to end-user operating companies worldwide. Information dissemination methods described included informal communication, intercompany meetings, visits by COFRC personnel to operating company offices, distribution of written reports,…

  1. Pacific Northwest Laboratory annual report for 1993 to the DOE Office of Energy Research. Part 2: Environmental sciences

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-04-01

    This 1993 Annual Report from Pacific Northwest Laboratory (PNL) to the US DOE describes research in environment and health conducted during fiscal year (FY) 1993. The report is divided into four parts, each in a separate volume. This part, Volume 2, covers Environmental Sciences. The research is directed toward developing a fundamental understanding of subsurface and terrestrial systems as a basis for both managing these critical resources and addressing environmental problems such as environmental restoration and global change. There are sections on Subsurface Science, Terrestrial Science, Technology Transfer, Interactions with Educational Institutions, and Laboratory Directed Research and Development.

  2. PCDAS Version 2. 2: Remote network control and data acquisition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fishbaugher, M.J.

    1987-09-01

    This manual is intended for both technical and non-technical people who want to use the PCDAS remote network control and data acquisition software. If you are unfamiliar with remote data collection hardware systems designed at Pacific Northwest Laboratory (PNL), this introduction should answer your basic questions. Even if you have some experience with the PNL-designed Field Data Acquisition Systems (FDAS), it would be wise to review this material before attempting to set up a network. This manual was written based on the assumption that you have a rudimentary understanding of personal computer (PC) operations using Disk Operating System (DOS) versionmore » 2.0 or greater (IBM 1984). You should know how to create subdirectories and get around the subdirectory tree.« less

  3. A Moveable Feast--A Progressive Approach to the Unit Operations Laboratory

    ERIC Educational Resources Information Center

    Conner, Wm. Curtis, Jr.; Hammond, Karl D.; Laurence, Robert L.

    2011-01-01

    The authors describe an alternative format for the senior laboratory in which students are allowed--indeed, expected--to communicate with previous groups and build on their results. The effect is a unit operations laboratory in which students are empowered to propose the experiments they wish to do and in which the cumulative experience of the…

  4. Design of a Clinical Information Management System to Support DNA Analysis Laboratory Operation

    PubMed Central

    Dubay, Christopher J.; Zimmerman, David; Popovich, Bradley

    1995-01-01

    The LabDirector system has been developed at the Oregon Health Sciences University to support the operation of our clinical DNA analysis laboratory. Through an iterative design process which has spanned two years, we have produced a system that is both highly tailored to a clinical genetics production laboratory and flexible in its implementation, to support the rapid growth and change of protocols and methodologies in use in the field. The administrative aspects of the system are integrated with an enterprise schedule management system. The laboratory side of the system is driven by a protocol modeling and execution system. The close integration between these two aspects of the clinical laboratory facilitates smooth operations, and allows management to accurately measure costs and performance. The entire application has been designed and documented to provide utility to a wide range of clinical laboratory environments.

  5. Adaptation of Professional Skills in the Unit Operations Laboratory

    ERIC Educational Resources Information Center

    Rende, Deniz; Rende, Sevinc; Baysal, Nihat

    2012-01-01

    We introduce the design of three consecutive unit operations laboratory (UOL) courses that retain the academic rigor of the course while incorporating skills essential for professional careers, such as ability to propose ideas, develop practical solutions, participate in teamwork, meet deadlines, establish communication between technical support…

  6. Operating environmental laboratories--an overview of analysis equipment procurement and management.

    PubMed

    Pandya, G H; Shinde, V M; Kanade, G S; Kondawar, V K

    2003-10-01

    Management of equipment in an environmental laboratory requires planning involving assessment of the workload on a particular equipment, establishment of criteria and specification for the purchase of equipment, creation of infrastructure for installation and testing of the equipment, optimization of analysis conditions, development of preventive maintenance procedures and establishment of in-house repair facilities. The paper reports the results of such an analysis carried for operating environmental laboratories associated with R& D work, serving as an Govt. laboratory or attached to an Industry for analysing industrial emissions.

  7. Simulation for analysis and control of superplastic forming. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zacharia, T.; Aramayo, G.A.; Simunovic, S.

    1996-08-01

    A joint study was conducted by Oak Ridge National Laboratory (ORNL) and the Pacific Northwest Laboratory (PNL) for the U.S. Department of Energy-Lightweight Materials (DOE-LWM) Program. the purpose of the study was to assess and benchmark the current modeling capabilities with respect to accuracy of predictions and simulation time. Two modeling capabilities with respect to accuracy of predictions and simulation time. Two simulation platforms were considered in this study, which included the LS-DYNA3D code installed on ORNL`s high- performance computers and the finite element code MARC used at PNL. both ORNL and PNL performed superplastic forming (SPF) analysis on amore » standard butter-tray geometry, which was defined by PNL, to better understand the capabilities of the respective models. The specific geometry was selected and formed at PNL, and the experimental results, such as forming time and thickness at specific locations, were provided for comparisons with numerical predictions. Furthermore, comparisons between the ORNL simulation results, using elasto-plastic analysis, and PNL`s results, using rigid-plastic flow analysis, were performed.« less

  8. Development and Operation of a MUMPS Laboratory Information System: A Decade's Experience

    PubMed Central

    Miller, R. E.; Causey, J. P.; Moore, G. W.; Wilk, G. E.

    1988-01-01

    We describe more than a decade's experience with inhouse development and operation of a clinical laboratory computer system written in the MUMPS programming language for a 1000 bed teaching hospital. The JHLIS is a networked minicomputer system that supports accessioning, instrument monitoring, and result reporting for over 3000 specimens and 30,000 test results daily. Development and operation of the system accounts for 6% of the budget of the laboratories which have had a 70% increase in workload over the past decade. Our experience with purchased MUMPS software maintained and enhanced inhouse suggests an attractive alternative to lengthy inhouse development.

  9. An Operationally Simple Sonogashira Reaction for an Undergraduate Organic Chemistry Laboratory Class

    ERIC Educational Resources Information Center

    Cranwell, Philippa B.; Peterson, Alexander M.; Littlefield, Benjamin T. R.; Russell, Andrew T.

    2015-01-01

    An operationally simple, reliable, and cheap Sonogashira reaction suitable for an undergraduate laboratory class that can be completed within a day-long (8 h) laboratory session has been developed. Cross-coupling is carried out between 2-methyl-3-butyn-2-ol and various aryl iodides using catalytic amounts of bis(triphenylphosphine)palladium(II)…

  10. [Standardization of operation monitoring and control of the clinical laboratory automation system].

    PubMed

    Tao, R

    2000-10-01

    Laboratory automation systems showed up in the 1980s and have been introduced to many clinical laboratories since early 1990s. Meanwhile, it was found that the difference in the specimen tube dimensions, specimen identification formats, specimen carrier transportation equipment architecture, electromechanical interfaces between the analyzers and the automation systems was preventing the systems from being introduced to a wider extent. To standardize the different interfaces and reduce the cost of laboratory automation, NCCLS and JCCLS started establishing standards for laboratory automation in 1996 and 1997 respectively. Operation monitoring and control of the laboratory automation system have been included in their activities, resulting in the publication of an NCCLS proposed standard in 1999.

  11. 76 FR 17367 - National Voluntary Laboratory Accreditation Program; Operating Procedures

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-29

    ... DEPARTMENT OF COMMERCE National Institute of Standards and Technology 15 CFR Part 285 [Docket No: 110125063-1062-02] RIN 0693-AB61 National Voluntary Laboratory Accreditation Program; Operating Procedures AGENCY: National Institute of Standards and Technology (NIST), Commerce. ACTION: Notice of proposed...

  12. An Automated Distillation Column for the Unit Operations Laboratory

    ERIC Educational Resources Information Center

    Perkins, Douglas M.; Bruce, David A.; Gooding, Charles H.; Butler, Justin T.

    2005-01-01

    A batch distillation apparatus has been designed and built for use in the undergraduate unit operations laboratory course. The column is fully automated and is accompanied by data acquisition and control software. A mixture of 1­-propanol and 2-­propanol is separated in the column, using either a constant distillate rate or constant composition…

  13. Supplement analysis for continued operation of Lawrence Livermore National Laboratory and Sandia National Laboratories, Livermore. Volume 2: Comment response document

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1999-03-01

    The US Department of Energy (DOE), prepared a draft Supplement Analysis (SA) for Continued Operation of Lawrence Livermore National Laboratory (LLNL) and Sandia National Laboratories, Livermore (SNL-L), in accordance with DOE`s requirements for implementation of the National Environmental Policy Act of 1969 (NEPA) (10 Code of Federal Regulations [CFR] Part 1021.314). It considers whether the Final Environmental Impact Statement and Environmental Impact Report for Continued Operation of Lawrence Livermore National Laboratory and Sandia National Laboratories, Livermore (1992 EIS/EIR) should be supplement3ed, whether a new environmental impact statement (EIS) should be prepared, or no further NEPA documentation is required. The SAmore » examines the current project and program plans and proposals for LLNL and SNL-L, operations to identify new or modified projects or operations or new information for the period from 1998 to 2002 that was not considered in the 1992 EIS/EIR. When such changes, modifications, and information are identified, they are examined to determine whether they could be considered substantial or significant in reference to the 1992 proposed action and the 1993 Record of Decision (ROD). DOE released the draft SA to the public to obtain stakeholder comments and to consider those comments in the preparation of the final SA. DOE distributed copies of the draft SA to those who were known to have an interest in LLNL or SNL-L activities in addition to those who requested a copy. In response to comments received, DOE prepared this Comment Response Document.« less

  14. Pacific Northwest Laboratory annual report for 1989 to the DOE Office of Energy Research - Part 1: Biomedical Sciences

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, J.F.

    This report summarizes progress on OHER human health, biological, general life sciences, and medical applications research programs conducted at PNL in FY 1989. The research develops the knowledge and scientific principles necessary to identify, understand, and anticipate the long-term health consequences of energy-related radiation and chemicals. Our continuing emphasis is to decrease the uncertainty of health risk estimates from existing and developing energy-related technologies through an increased understanding of how radiation and chemicals cause biological damage. The sequence of this report of PNL research reflects the OHER programmatic structure. The first section, on human health research, concerns statistical and epidemiologicalmore » studies for assessing health risks. The next section contains reports of biological research in laboratory animals and in vitro cell systems, including research with radionuclides and chemicals. The general life sciences research section reports research conducted for the OHER human genome research program, and the medical applications section summarizes commercial radioisotope production and distribution activities at DOE facilities. 6 refs., 50 figs., 35 tabs.« less

  15. Low crustal velocities and mantle lithospheric variations in southern Tibet from regional Pnl waveforms

    NASA Astrophysics Data System (ADS)

    Rodgers, Arthur J.; Schwartz, Susan Y.

    We report low average crustal P-wave velocities (5.9-6.1 km/s, Poisson's ratio 0.23-0.27, thickness 68-76 km) in southern Tibet from modelling regional Pnl waveforms recorded by the 1991-1992 Tibetan Plateau Experiment. We also find that the mantle lithosphere beneath the Indus-Tsangpo Suture and the Lhasa Terrane is shield-like (Pn velocity 8.20-8.25 km/s, lid thickness 80-140 km, positive velocity gradient 0.0015-0.0025 s-1). Analysis of relative Pn travel time residuals requires a decrease in the mantle velocities beneath the northern Lhasa Terrane, the Banggong-Nujiang Suture and the southern Qiangtang Terrane. Tectonic and petrologic considerations suggest that low bulk crustal velocities could result from a thick (50-60 km) felsic upper crust with vertically limited and laterally pervasive partial melt. These results are consistent with underthrusting of Indian Shield lithosphere beneath the Tibetan Plateau to at least the central Lhasa Terrane.

  16. Pacific Northwest Laboratory annual report for 1993 to the DOE Office of Energy Research. Part 1: Biomedical Sciences

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lumetta, C.C.; Park, J.F.

    1994-03-01

    This report summarizes FY 1993 progress in biological and general life sciences research programs conducted for the Department of Energy`s Office of Health and Environmental REsearch (OHER) at Pacific Northwest Laboratory (PNL). This research provides knowledge of fundamental principles necessary to identify, understand, and anticipate the long-term health consequences of exposure to energy-related radiation and chemicals. The Biological Research section contains reports of studies using laboratory animals, in vitro cell systems, and molecular biological systems. This research includes studies of the impact of radiation, radionuclides, and chemicals on biological responses at all levels of biological organization. The General Life Sciencesmore » Research section reports research conducted for the OHER human genome program.« less

  17. A Manual of Simplified Laboratory Methods for Operators of Wastewater Treatment Facilities.

    ERIC Educational Resources Information Center

    Westerhold, Arnold F., Ed.; Bennett, Ernest C., Ed.

    This manual is designed to provide the small wastewater treatment plant operator, as well as the new or inexperienced operator, with simplified methods for laboratory analysis of water and wastewater. It is emphasized that this manual is not a replacement for standard methods but a guide for plants with insufficient equipment to perform analyses…

  18. The Development and Deployment of a Virtual Unit Operations Laboratory

    ERIC Educational Resources Information Center

    Vaidyanath, Sreeram; Williams, Jason; Hilliard, Marcus; Wiesner, Theodore

    2007-01-01

    Computer-simulated experiments offer many benefits to engineering curricula in the areas of safety, cost, and flexibility. We report our experience in developing and deploying a computer-simulated unit operations laboratory, driven by the guiding principle of maximum fidelity to the physical lab. We find that, while the up-front investment in…

  19. When routine D-J implantation necessary during PNL?

    PubMed

    Bayrak, Omer; Seckiner, Ilker; Erturhan, Sakip M; Bulut, Ersan; Demirbag, Asaf; Erbagci, Asaf

    2015-03-01

    We investigated the characteristics of patients who underwent Double-J catheter (D-J) implantation, the risk factors for prolonged urine leakage (PUL), and prediction of patients who require medical treatment. The data of 535 adult patients who underwent PNL due to kidney stone disease between January 2005 and December 2011 in our clinic were analyzed retrospectively. Patients were divided into 2 groups: Group 1 (n=77) (14.39%) included patients with Double-J catheter due to prolonged (> 24 h) urinary leakage and Group 2 (n=458) (85.61%) patients without urinary leakage. The mean stone burden was 951.94 ± 539.09 mm2 in Group 1, and 676.35 ±296.65 mm2 in Group 2 (p<0.05). DJ catheter was implanted in 11.33% of the patients with stone burden below 1000 mm2 versus in 51.21% of the patients with stone burden above 1000 mm2. In Group 1, the number of patients with two or more accesses performed was 18.18, whereas in Group 2 it was 8.5% (p<0.05). Among all patients, DJ implantation was performed in 13.07% of patients with a single access versus 26.41% of patients with two or more accesses. Also, DJ catheter was implanted in 41.46%of patients with residual stones versus 12.14% of stone-free patients. Three patients with stone burden above 1000 mm2, two or more accesses, and residual stone, all of them required DJ implantation. DJ implantation due to PUL had approximately 5-fold increase stone burden above 1000 mm2, 2-fold increase in patients undergoing two or more access and 3-fold increase in patients with residual stones. Therefore, we think that the D-J implantation is highly advisable in case of a stone load above 1000 mm2, two or more accesses, and in patients with residual stones.

  20. Geomorphic Modeling of Macro-Tidal Embayment with Extensive Tidal Flats: Skagit Bay, Washington

    DTIC Science & Technology

    2010-09-30

    Geomorphic modeling of macro-tidal embayment with extensive tidal flats: Skagit Bay , Washington Lyle Hibler Battelle-Pacific Northwest Division...Marine Sciences Laboratory Sequim , WA 98382 phone: (360) 681-3616 fax: (360) 681-4559 email: lyle.hibler@pnl.gov Adam Maxwell Battelle-Pacific...Northwest Division Marine Sciences Laboratory Sequim , WA 98382 phone: (360) 681-4591 fax: (360) 681-4559 email: adam.maxwell@pnl.gov Award

  1. Beyond prone position in percutaneous nephrolithotomy: a comprehensive review.

    PubMed

    de la Rosette, Jean J M C H; Tsakiris, Peter; Ferrandino, Michael N; Elsakka, Ahmed M; Rioja, Jorge; Preminger, Glenn M

    2008-12-01

    Percutaneous nephrolithotomy (PNL) is traditionally performed with the patient in the prone position. To assess the efficacy and safety of the prone and supine positions, particularly in obese patients and in those with staghorn calculi. A Medline search was conducted for articles published during the last 10 yr related to PNL in the prone and supine positions. This search revealed 9 published studies for supine and 25 for prone PNL. None of the supine PNL studies reported visceral injuries, while transfusion rates were 0.0-9.4% and stone-free rates were 69.6-95.0%. One study of supine PNL evaluated a significant proportion of obese patients. Prone PNL studies in obese patients report transfusion rates of 3.2-8.8% and stone-free rates of 79.0-89.2%. In the only randomized study, excluding obese patients and staghorn calculi, operative time favors the supine position. A nonrandomized comparative study demonstrated similar complication rates with insignificant improvement in treatment success for supine PNL; however, when comparing series with similar proportions of staghorn calculi cases, there are slightly improved outcomes for prone PNL. Moreover, comparison of weighted means favors prone PNL. For obese patients and staghorn calculi, prone PNL appears to be associated with decreased operative times with similar bleeding rates and slightly better stone-free rates than supine PNL.

  2. ECIRS (Endoscopic Combined Intrarenal Surgery) in the Galdakao-modified supine Valdivia position: a new life for percutaneous surgery?

    PubMed

    Cracco, Cecilia Maria; Scoffone, Cesare Marco

    2011-12-01

    Percutaneous nephrolithotomy (PNL) is still the gold-standard treatment for large and/or complex renal stones. Evolution in the endoscopic instrumentation and innovation in the surgical skills improved its success rate and reduced perioperative morbidity. ECIRS (Endoscopic Combined IntraRenal Surgery) is a new way of affording PNL in a modified supine position, approaching antero-retrogradely to the renal cavities, and exploiting the full array of endourologic equipment. ECIRS summarizes the main issues recently debated about PNL. The recent literature regarding supine PNL and ECIRS has been reviewed, namely about patient positioning, synergy between operators, procedures, instrumentation, accessories and diagnostic tools, step-by-step standardization along with versatility of the surgical sequence, minimization of radiation exposure, broadening to particular and/or complex patients, limitation of post-operative renal damage. Supine PNL and ECIRS are not superior to prone PNL in terms of urological results, but guarantee undeniable anesthesiological and management advantages for both patient and operators. In particular, ECIRS requires from the surgeon a permanent mental attitude to synergy, standardized surgical steps, versatility and adherence to the ongoing clinical requirements. ECIRS can be performed also in particular cases, irrespective to age or body habitus. The use of flexible endoscopes during ECIRS contributes to minimizing radiation exposure, hemorrhagic risk and post-PNL renal damage. ECIRS may be considered an evolution of the PNL procedure. Its proposal has the merit of having triggered the critical analysis of the various PNL steps and of patient positioning, and of having transformed the old static PNL into an updated approach.

  3. A prospective randomized study comparing percutaneous nephrolithotomy under combined spinal-epidural anesthesia with percutaneous nephrolithotomy under general anesthesia.

    PubMed

    Singh, Vishwajeet; Sinha, Rahul Janak; Sankhwar, S N; Malik, Anita

    2011-01-01

    A prospective randomized study was executed to compare the surgical parameters and stone clearance in patients who underwent percutaneous nephrolithotomy (PNL) under combined spinal-epidural anesthesia (CSEA) versus those who underwent PNL under general anesthesia (GA). Between January 2008 to December 2009, 64 patients with renal calculi were randomized into 2 groups and evaluated for the purpose of this study. Group 1 consisted of patients who underwent PNL under CSEA and Group 2 consisted of patients who underwent PNL under GA. The operative time, stone clearance rate, visual pain analog score, mean analgesic dose and mean hospital stay were compared amongst other parameters. The difference between visual pain analog score after the operation and the dose of analgesic requirement was significant on statistical analysis between both groups. PNL under CSEA is as effective and safe as PNL under GA. Patients who undergo PNL under CESA require lesser analgesic dose and have a shorter hospital stay. Copyright © 2011 S. Karger AG, Basel.

  4. [Construction and operation status of management system of laboratories of schistosomiasis control institutions in Hubei Province].

    PubMed

    Zhao-Hui, Zheng; Jun, Qin; Li, Chen; Hong, Zhu; Li, Tang; Zu-Wu, Tu; Ming-Xing, Zeng; Qian, Sun; Shun-Xiang, Cai

    2016-10-09

    To analyze the construction and operation status of management system of laboratories of schistosomiasis control institutions in Hubei Province, so as to provide the reference for the standardized detection and management of schistosomiasis laboratories. According to the laboratory standard of schistosomiasis at provincial, municipal and county levels, the management system construction and operation status of 60 schistosomiasis control institutions was assessed by the acceptance examination method from 2013 to 2015. The management system was already occupied over all the laboratories of schistosomiasis control institutions and was officially running. There were 588 non-conformities and the inconsistency rate was 19.60%. The non-conformity rate of the management system of laboratory quality control was 38.10% (224 cases) and the non-conformity rate of requirements of instrument and equipment was 23.81% (140 cases). The management system has played an important role in the standardized management of schistosomiasis laboratories.

  5. [Clinical analysis of percutaneous nephrolithotomy for staghorn calculi with different stone branch number].

    PubMed

    Qi, Shi-yong; Zhang, Zhi-hong; Zhang, Chang-wen; Liu, Ran-lu; Shi, Qi-duo; Xu, Yong

    2013-12-01

    To investigate the impact of staghorn stone branch number on outcomes of percutaneous nephrolithotomy (PNL). From January 2009 to January 2013, the 371 patients with staghorn stones who were referred to our hospital for PNL were considered for this study. All calculi were showed with CT 3-dimentional reconstruction (3-DR) imaging. The computerized database of the patients had been reviewed. Our exclusion criterion was patients with congenital renal anomalies, such as horse-shoe and ectopic kidneys. And borderline stones that branched to one major calyx only were also not included. From 3-DR images, the number of stone branching into minor renal calices was recorded. We made "3" as the branch breakdown between groups. And the patients were divided into four groups. The number of percutaneous tract, operative time, staged PNL, intra-operative blood loss, complications, stone clearance rate, and postoperative hospital day were compared. The 371 patients (386 renal units) underwent PNL successfully, included 144 single-tract PNL, 242 multi-tract PNL, 97 staged PNL. The average operative time was (100 ± 50) minutes; the average intra-operative blood loss was (83 ± 67) ml. The stone clearance rate were 61.7% (3 days) and 79.5% (3 months). The postoperative hospital stay was (6.9 ± 3.4) days. A significantly higher ratio of multi-tract (χ(2) = 212.220, P < 0.01) and staged PNL (χ(2) = 49.679, P < 0.01), longer operative time (F = 4.652, P < 0.01) and postoperative hospital day (F = 2.067, P = 0.043) and lower rate of stone clearance (χ(2) = 10.691 and 47.369, P < 0.05) were found in PNL for calculi with stone branch number ≥ 5. There was no statistically meaningful difference among the 4 groups based on Clavien complication system (P = 0.460). The possibility of multi-tract and staged PNL, lower rate of stone clearance and longer postoperative hospital day increase for staghorn calculi with stone branch number more than 5.

  6. Performance testing of radiobioassay laboratories: In vivo measurements, Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacLellan, J.A.; Traub, R.J.; Olsen, P.C.

    1990-04-01

    A study of two rounds of in vivo laboratory performance testing was undertaken by Pacific Northwest Laboratory (PNL) to determine the appropriateness of the in vivo performance criteria of draft American National Standards Institute (ANSI) standard ANSI N13.3, Performance Criteria for Bioassay.'' The draft standard provides guidance to in vivo counting facilities regarding the sensitivity, precision, and accuracy of measurements for certain categories of commonly assayed radionuclides and critical regions of the body. This report concludes the testing program by presenting the results of the Round Two testing. Testing involved two types of measurements: chest counting for radionuclide detection inmore » the lung, and whole body counting for detection of uniformly distributed material. Each type of measurement was further divided into radionuclide categories as defined in the draft standard. The appropriateness of the draft standard criteria by measuring a laboratory's ability to attain them were judged by the results of both round One and Round Two testing. The testing determined that performance criteria are set at attainable levels, and the majority of in vivo monitoring facilities passed the criteria when complete results were submitted. 18 refs., 18 figs., 15 tabs.« less

  7. Efficiency in pathology laboratories: a survey of operations management in NHS bacteriology.

    PubMed

    Szczepura, A K

    1991-01-01

    In recent years pathology laboratory services in the U.K. have experienced large increases in demand. But the extent to which U.K. laboratories have introduced controls to limit unnecessary procedures within the laboratory was previously unclear. This paper presents the results of a survey of all 343 NHS bacteriology laboratories which records the extent to which such operations management controls are now in place. The survey shows large differences between laboratories. Quality controls over inputs, the use of screening tests as a culture substitute, the use of direct susceptibility testing, controls over routine antibiotic susceptibility testing, and controls over reporting of results all vary widely. The survey also records the prevalence of hospital antibiotic policies, the extent to which laboratories produce antibiograms for user clinicians, the degree of computerisation in data handling, and the degree of automation in processing specimens. Finally, the survey uncovers a large variation between NHS labs in the percentage of bacteriology samples which prove positive and lead to antibiotic susceptibility tests being carried out.

  8. Mini vs standard percutaneous nephrolithotomy for renal stones: a comparative study.

    PubMed

    ElSheemy, Mohammed S; Elmarakbi, Akram A; Hytham, Mohammed; Ibrahim, Hamdy; Khadgi, Sanjay; Al-Kandari, Ahmed M

    2018-03-16

    To compare the outcome of mini-percutaneous nephrolithotomy (Mini-PNL) versus standard-PNL for renal stones. Retrospective study was performed between March 2010 and May 2013 for patients treated by Mini-PNL or standard-PNL through 18 and 30 Fr tracts, respectively, using pneumatic lithotripsy. Semirigid ureteroscope (8.5/11.5 Fr) was used for Mini-PNL and 24 Fr nephroscope for standard-PNL. Both groups were compared in stone free rate(SFR), complications and operative time using Student-t, Mann-Whitney, Chi square or Fisher's exact tests as appropriate in addition to logistic regression analysis. P < 0.05 was considered statistically significant. Mini-PNL (378) and standard-PNL (151) were nearly comparable in patients and stones criteria including stone burden (3.77 ± 2.21 vs 3.77 ± 2.43 cm 2 ; respectively). There was no significant difference in number of tracts or supracostal puncture. Mini-PNL had longer operative time (68.6 ± 29.09 vs 60.49 ± 11.38 min; p = 0.434), significantly shorter hospital stay (2.43 ± 1.46 vs 4.29 ± 1.28 days) and significantly higher rate of tubeless PNL (75.1 vs 4.6%). Complications were significantly higher in standard-PNL (7.9 vs 20.5%; p < 0.001). SFR was significantly lower in Mini-PNL (89.9 vs 96%; p = 0.022). This significant difference was found with multiple stones and large stone burden (> 2 cm 2 ), but the SFR was comparable between both groups with single stone or stone burden ≤ 2 cm. Logistic regression analysis confirmed significantly higher complications and SFR with standard-PNL but with significantly shorter operative time. Mini-PNL has significantly lower SFR when compared to standard-PNL (but clinically comparable) with markedly reduced complications and hospital stay. Most of cases can be performed tubeless. The significant difference in SFR was found with multiple stones or large stone burden (> 2 cm 2 ), but not with single stones or stone burden

  9. Laparoscopy assisted percutaneous stone surgery can be performed in multiple ways for pelvic ectopic kidneys.

    PubMed

    Soylemez, Haluk; Penbegül, Necmettin; Utangac, Mehmet Mazhar; Dede, Onur; Çakmakçı, Süleyman; Hatipoglu, Namık Kemal

    2016-08-01

    Pelvic kidney stones remain a unique challenge to the endourologists. Treatment options include open surgery, extracorporeal shockwave lithotripsy, percutaneous nephrolithotomy (PNL), retrograde intrarenal surgery, and laparoscopy assisted PNL (LA-PNL). As a minimal invasive option, LA-PNL can decrease the risk for bowel and major vessel injury. Here, we describe our experience using the LA-PNL procedures with different combinations, to treat kidney stones in multiple patients with a pelvic ectopic kidney (PEK). Eight patients, with PEK, kidney stones, and no other treatment choice, but open surgery, were included in the study. Two different laparoscopic techniques such as mesocolon dissection and transmesocolic, and four different percutaneous procedures such as standard-PNL, mini-PNL, micro-PNL, and a PNL through the renal pelvis were used for stone extraction in these patients. The mean age of patients was 25.6 ± 12.9 years and mean stone size was 524.1 ± 430.3 mm(2). Mean operation time was 150.5 ± 40.0 (77-210) min which was composed of retrograde catheterization (14.8 ± 2.9 min), laparoscopic procedure (48.7 ± 20.6 min) and PNL procedure (86.8 ± 31.1 min). Residual stones were seen in two patients (no additional treatment was need), while a 'stone-free' procedure was achieved in six patients (75.0 %). On the post-operative first month visit, a stone was observed on radiological examinations in only one patient (87.5 % stone-free). Mean hospitalization time was 2.8 ± 0.9 days. No perioperative or post-operative complication was observed in all patients. LA-PNL surgery is a safe and effective option for treatment of PEK stones, and has several alternative approaches.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The Department of Energy Order DOE 5000.4A establishes DOE`s policy and guidelines regarding Laboratory Directed Research and Development (LDRD) at its multiprogram laboratories. As described in 5000.4A, LDRD is ``research and development of a creative and innovative nature which is selected by the Laboratory Director or his or her designee, for the purpose of maintaining the scientific and technological vitality of the Laboratory and to respond to scientific and technological opportunities in conformance with the guidelines in this Order. LDRD includes activities previously defined as ER&D, as well as other discretionary research and development activities not provided for in amore » DOE program.`` Consistent with the Mission Statement and Strategic Plan provided in PNL`s Institutional Plan, the LDRD investments are focused on developing new and innovative approaches in research related to our ``core competencies.`` Currently, PNL`s core competencies have been identified as integrated environmental research; process technology; energy systems research. In this report, the individual summaries of Laboratory-level LDRD projects are organized according to these core competencies. The largest proportion of Laboratory-level LDRD funds is allocated to the core competency of integrated environmental research. A significant proportion of PNL`s LDRD funds are also allocated to projects within the various research centers that are proposed by individual researchers or small research teams. The projects are described in Section 2.0. The projects described in this report represent PNL`s investment in its future and are vital to maintaining the ability to develop creative solutions for the scientific and technical challenges faced by DOE and the nation. In accordance with DOE guidelines, the report provides an overview of PNL`s LDRD program and the management process used for the program and project summaries for each LDRD project.« less

  11. Automated Scheduling of Personnel to Staff Operations for the Mars Science Laboratory

    NASA Technical Reports Server (NTRS)

    Knight, Russell; Mishkin, Andrew; Allbaugh, Alicia

    2014-01-01

    Leveraging previous work on scheduling personnel for space mission operations, we have adapted ASPEN (Activity Scheduling and Planning Environment) [1] to the domain of scheduling personnel for operations of the Mars Science Laboratory. Automated scheduling of personnel is not new. We compare our representations to a sampling of employee scheduling systems available with respect to desired features. We described the constraints required by MSL personnel schedulers and how each is handled by the scheduling algorithm.

  12. The influence of percutaneous nephrolithotomy on human systemic stress response, SIRS and renal function.

    PubMed

    Shen, Pengfei; Wei, Wuran; Yang, Xiaochun; Zeng, Hao; Li, Xiong; Yang, Jie; Wang, Jia; Huang, Jiaoti

    2010-10-01

    The objective of this study is to investigate the influences of percutaneous nephrolithotomy (PNL) and open surgery nephrolithotomy on the systemic stress response, SIRS and renal function. Forty patients with kidney calculi were enrolled in the study. Twenty cases were randomized to the PNL group and the other twenty cases to the open surgery group. Levels of C-reactive protein (CRP), interleukin-6(IL-6), β(2)-microglobulin (β(2)-MG), respiration rate, heart rate, body temperature and white blood cell counts were examined. CRP and IL-6 were measured in all patients pre-operatively and on post-operative days 1, 3 and 6, respectively. There was significant difference in their pre- and post-operation levels (P < 0.05), with the peak of CRP and IL-6 observed at post-operative days 3 and 1, respectively. There was significant difference in both CRP and IL-6 between the two groups (P < 0.05). At post-operative day 1, there were 5 cases of SIRS in PNL group and 12 cases in open surgery group; there was significant difference between the two groups (P < 0.05). Serum β(2)-MG levels were measured as the same time as CRP and no significant changes were observed within or between the groups (P > 0.05). Urine β(2)-MG levels were also measured. There was significant difference between pre- and the first day post-PNL (P < 0.05); there was no significant difference between pre- and the third and sixth day post-PNL (P > 0.05). There was significant difference between pre- and first and third day post-open surgery (P < 0.05); but there was no significant difference between pre- and the sixth day post-open surgery (P > 0.05). There was significant difference between two groups at the first, third and sixth days (P < 0.05). The systemic stress response is activated both in PNL group and open surgery group to some extent. The degree of stress response of PNL is lower than that of open surgery, proving the advantages of PNL with reference to serum immunology. There were cases in

  13. Continuous AE crack monitoring of a dissimilar metal weldment at Limerick Unit 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hutton, P.H.; Friesel, M.A.; Dawson, J.F.

    1993-12-01

    Acoustic emission (AE) technology for continuous surveillance of a reactor component(s) to detect crack initiation and/or crack growth has been developed at Pacific Northwest Laboratory (PNL). The technology was validated off-reactor in several major tests, but it had not been validated by monitoring crack growth on an operating reactor system. A flaw indication was identified during normal inservice inspection of piping at Philadelphia Electric Company (PECO) Limerick Unit 1 reactor during the 1989 refueling outage. Evaluation of the flaw indication showed that it could remain in place during the subsequent fuel cycle without compromising safety. The existence of this flawmore » indication offered a long sought opportunity to validate AE surveillance to detect and evaluate crack growth during reactor operation. AE instrumentation was installed by PNL and PECO to monitor the flaw indication during two complete fuel cycles. This report discusses the results obtained from the AE monitoring over the period May 1989 to March 1992 (two fuel cycles).« less

  14. User Guide: How to Use and Operate Virtual Reality Equipment in the Systems Assessment and Usability Laboratory (SAUL) for Conducting Demonstrations

    DTIC Science & Technology

    2017-08-01

    ARL-TN-0839 ● AUG 2017 US Army Research Laboratory User Guide: How to Use and Operate Virtual Reality Equipment in the Systems...ARL-TN-0839 ● AUG 2017 US Army Research Laboratory User Guide: How to Use and Operate Virtual Reality Equipment in the Systems...September 2017 4. TITLE AND SUBTITLE User Guide: How to Use and Operate Virtual Reality Equipment in the Systems Assessment and Usability Laboratory

  15. Meier associates and Pacific Northwest Laboratory staff exchange: Transfer of corrosion monitoring expertise to assess and develop in-line inspection tools for corrosion control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Olson, N.J.; Meier, T.E.

    1995-04-01

    Staff exchanges, such as the one described in this report, are intended to facilitate communication and collaboration among scientists and engineers at DOE laboratories, in US industry, and academia. During the past 5 years, PNL has developed prototype instrumentation to automate the data collection required for electrochemical determination of corrosion rates and behavior of materials in various electrically conductive environments. The last version is labeled the Sentry 100 prototype corrosion data scanner. Applications include these in the pulp and paper industry and at hazardous waste sites.

  16. Electrochemical noise measurements of sustained microbially influenced pitting corrosion in a laboratory flow loop system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Y.; Frank, J.R.; St. Martin, E.J.

    Because of the chaotic nature of the corrosion process and the complexity of the electrochemical noise signals that are generated, there is no generally accepted method of measuring and interpreting these signals that allows the consistent detection and identification of sustained localized pitting (SLP) as compared to general corrosion. The authors have reexamined electrochemical noise analysis (ENA) of localized corrosion using different hardware, signal collection, and signal processing designs than those used in conventional ENA techniques. The new data acquisition system was designed to identify and monitor the progress of SLP by analyzing the power spectral density (PSD) of themore » trend of the corrosion current noise level (CNL) and potential noise level (PNL). Each CNL and PNL data point was calculated from the root-mean-square value of the ac components of current and potential fluctuation signals, which were measured simultaneously during a short time period. The PSD analysis results consistently demonstrated that the trends of PNL and CNL contain information that can be used to differentiate between SLP and general corrosion mechanisms. The degree of linear slope in the low-frequency portion of the PSD analysis was correlated with the SLP process. Laboratory metal coupons as well as commercial corrosion probes were tested to ensure the reproducibility and consistency of the results. The on-line monitoring capability of this new ENA method was evaluated in a bench-scale flow-loop system, which simulated microbially influenced corrosion (MIC) activity. The conditions in the test flow-loop system were controlled by the addition of microbes and different substrates to favor accelerated corrosion. The ENA results demonstrated that this in-situ corrosion monitoring system could effectively identify SLP corrosion associated with MIC, compared to a more uniform general corrosion mechanism. A reduction in SLP activity could be clearly detected by the ENA

  17. Electrochemical noise measurements of sustained microbially influenced pitting corrosion in a laboratory flow loop system.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Y. J.

    Because of the chaotic nature of the corrosion process and the complexity of the electrochemical noise signals that are generated, there is no generally accepted method of measuring and interpreting these signals that allows the consistent detection and identification of sustained localized pitting (SLP) as compared to general corrosion. We have reexamined electrochemical noise analysis (ENA) of localized corrosion using different hardware, signal collection, and signal processing designs than those used in conventional ENA techniques. The new data acquisition system was designed to identify and monitor the progress of SLP by analyzing the power spectral density (PSD) of the trendmore » of the corrosion current noise level (CNL) and potential noise level (PNL). Each CNL and PNL data point was calculated from the root-mean- square value of the ac components of current and potential fluctuation signals, which were measured simultaneously during a short time period. The PSD analysis results consistently demonstrated that the trends of PNL and CNL contain information that can be used to differentiate between SLP and general corrosion mechanisms. The degree of linear slope in the low-frequency portion of the PSD analysis was correlated with the SLP process. Laboratory metal coupons as well as commercial corrosion probes were tested to ensure the reproducibility and consistency of the results. The on-line monitoring capability of this new ENA method was evaluated in a bench-scale flow-loop system, which simulated microbially influenced corrosion (MIC) activity. The conditions in the test flow-loop system were controlled by the addition of microbes and different substrates to favor accelerated corrosion. The ENA results demonstrated that this in-situ corrosion monitoring system could effectively identify SLP corrosion associated with MIC, compared to a more uniform general corrosion mechanism. A reduction in SLP activity could be clearly detected by the ENA monitoring

  18. LANDSAT TM image data quality analysis for energy-related applications

    NASA Technical Reports Server (NTRS)

    Wukelic, G. E.; Foote, H. P.; Petrie, G. M.; Barnard, J. C.; Eliason, J. R.

    1985-01-01

    This project represents a no-cost agreement between National Aeronautic Space Administration Goddard Space Flight Center (NASA GSFC) and the Pacific Northwest Laboratory (PNL). PNL is a Department of Energy (DOE) national laboratory operted by Battelle Memorial Institute at its Pacific Northwest Laboratories in Richland, Washington. The objective of this investigation is to evaluate LANDSAT's thematic mapper (TM) data quality and utility characteristics from an energy research and technological perspective. Of main interest is the extent to which repetitive TM data might support DOE efforts relating to siting, developing, and monitoring energy-related facilities, and to basic geoscientific research. The investigation utilizes existing staff and facility capabilities, and ongoing programmatic activities at PNL and other DOE national laboratories to cooperatively assess the potential usefulness of the improved experimental TM data. The investigation involves: (1) both LANDSAT 4 and 5 TM data, (2) qualitative and quantitative use consideration, and 3) NASA P (corrected) and A (uncorrected) CCT analysis for a variety of sites of DOE interest. Initial results were presented at the LANDSAT Investigator's Workshops and at specialized LANDSAT TM sessions at various conferences.

  19. Trainee-Associated Factors and Proficiency at Percutaneous Nephrolithotomy.

    PubMed

    Aghamir, Seyed Mohammad Kazem; Behtash, Negar; Hamidi, Morteza; Farahmand, Hasan; Salavati, Alborz; Mortaz Hejri, Sara

    2017-07-01

    Percutaneous nephrolithotomy (PNL) is a complicated procedure for urology trainees. This study was designed to investigate the effect of trainees' ages and previous experience, as well as the number of operated cases, on proficiency at PNL by using patient outcomes. A cross sectional observational study was designed during a five-year period. Trainees in PNL fellowship programs were included. At the end of the program, the trainees' performance in PNL was assessed regarding five competencies and scored 1-5. If the overall score was 4 or above, the trainee was considered as proficient. The trainees' age at the beginning of the program and the years passed from their residency graduation were asked and recorded. Also, the number of PNL cases operated by each trainee was obtained via their logbooks. The age, years passed from graduation, and number of operated cases were compared between two groups of proficient and non-proficient trainees. Univariate and multivariate binary logistic regression analysis was applied to estimate the effect of aforementioned variables on the occurrence of the proficiency. Forty-two trainees were included in the study. The mean and standard deviation for the overall score were 3.40 (out of 5) and 0.67, respectively. Eleven trainees (26.2%) recognized as proficient in performing PNL. Univariate regression analysis indicated that each of three variables (age, years passed from graduation and number of operated cases) had statistically significant effect on proficiency. However, the multivariate regression analysis revealed that just the number of cases had significant effect on achieving proficiency. Although it might be assumed that trainees' age negatively correlates with their scores, in fact, it is their amount of practice that makes a difference. A certain number of cases is required to be operated by a trainee in order to reach the desired competency in PNL.

  20. Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 1. Biosafety Level 4 Suit Laboratory Suite Entry and Exit Procedures

    PubMed Central

    Janosko, Krisztina; Holbrook, Michael R.; Adams, Ricky; Barr, Jason; Bollinger, Laura; Newton, Je T'aime; Ntiforo, Corrie; Coe, Linda; Wada, Jiro; Pusl, Daniela; Jahrling, Peter B.; Kuhn, Jens H.; Lackemeyer, Matthew G.

    2016-01-01

    Biosafety level 4 (BSL-4) suit laboratories are specifically designed to study high-consequence pathogens for which neither infection prophylaxes nor treatment options exist. The hallmarks of these laboratories are: custom-designed airtight doors, dedicated supply and exhaust airflow systems, a negative-pressure environment, and mandatory use of positive-pressure (“space”) suits. The risk for laboratory specialists working with highly pathogenic agents is minimized through rigorous training and adherence to stringent safety protocols and standard operating procedures. Researchers perform the majority of their work in BSL-2 laboratories and switch to BSL-4 suit laboratories when work with a high-consequence pathogen is required. Collaborators and scientists considering BSL-4 projects should be aware of the challenges associated with BSL-4 research both in terms of experimental technical limitations in BSL-4 laboratory space and the increased duration of such experiments. Tasks such as entering and exiting the BSL-4 suit laboratories are considerably more complex and time-consuming compared to BSL-2 and BSL-3 laboratories. The focus of this particular article is to address basic biosafety concerns and describe the entrance and exit procedures for the BSL-4 laboratory at the NIH/NIAID Integrated Research Facility at Fort Detrick. Such procedures include checking external systems that support the BSL-4 laboratory, and inspecting and donning positive-pressure suits, entering the laboratory, moving through air pressure-resistant doors, and connecting to air-supply hoses. We will also discuss moving within and exiting the BSL-4 suit laboratories, including using the chemical shower and removing and storing positive-pressure suits. PMID:27768063

  1. Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 1. Biosafety Level 4 Suit Laboratory Suite Entry and Exit Procedures.

    PubMed

    Janosko, Krisztina; Holbrook, Michael R; Adams, Ricky; Barr, Jason; Bollinger, Laura; Newton, Je T'aime; Ntiforo, Corrie; Coe, Linda; Wada, Jiro; Pusl, Daniela; Jahrling, Peter B; Kuhn, Jens H; Lackemeyer, Matthew G

    2016-10-03

    Biosafety level 4 (BSL-4) suit laboratories are specifically designed to study high-consequence pathogens for which neither infection prophylaxes nor treatment options exist. The hallmarks of these laboratories are: custom-designed airtight doors, dedicated supply and exhaust airflow systems, a negative-pressure environment, and mandatory use of positive-pressure ("space") suits. The risk for laboratory specialists working with highly pathogenic agents is minimized through rigorous training and adherence to stringent safety protocols and standard operating procedures. Researchers perform the majority of their work in BSL-2 laboratories and switch to BSL-4 suit laboratories when work with a high-consequence pathogen is required. Collaborators and scientists considering BSL-4 projects should be aware of the challenges associated with BSL-4 research both in terms of experimental technical limitations in BSL-4 laboratory space and the increased duration of such experiments. Tasks such as entering and exiting the BSL-4 suit laboratories are considerably more complex and time-consuming compared to BSL-2 and BSL-3 laboratories. The focus of this particular article is to address basic biosafety concerns and describe the entrance and exit procedures for the BSL-4 laboratory at the NIH/NIAID Integrated Research Facility at Fort Detrick. Such procedures include checking external systems that support the BSL-4 laboratory, and inspecting and donning positive-pressure suits, entering the laboratory, moving through air pressure-resistant doors, and connecting to air-supply hoses. We will also discuss moving within and exiting the BSL-4 suit laboratories, including using the chemical shower and removing and storing positive-pressure suits.

  2. Model of rotary-actuated flexible beam with notch filter vibration suppression controller and torque feedforward load compensation controller

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bills, K.C.; Kress, R.L.; Kwon, D.S.

    1994-12-31

    This paper describes ORNL`s development of an environment for the simulation of robotic manipulators. Simulation includes the modeling of kinematics, dynamics, sensors, actuators, control systems, operators, and environments. Models will be used for manipulator design, proposal evaluation, control system design and analysis, graphical preview of proposed motions, safety system development, and training. Of particular interest is the development of models for robotic manipulators having at least one flexible link. As a first application, models have been developed for the Pacific Northwest Laboratory`s Flexible Beam Test Bed (PNL FBTB), which is a 1-Degree-of-Freedom, flexible arm with a hydraulic base actuator. ORNLmore » transferred control algorithms developed for the PNL FBTB to controlling IGRIP models. A robust notch filter is running in IGRIP controlling a full dynamics model of the PNL test bed. Model results provide a reasonable match to the experimental results (quantitative results are being determined) and can run on ORNL`s Onyx machine in approximately realtime. The flexible beam is modeled as six rigid sections with torsional springs between each segment. The spring constants were adjusted to match the physical response of the flexible beam model to the experimental results. The controller is able to improve performance on the model similar to the improvement seen on the experimental system. Some differences are apparent, most notably because the IGRIP model presently uses a different trajectory planner than the one used by ORNL on the PNL test bed. In the future, the trajectory planner will be modified so that the experiments and models are the same. The successful completion of this work provides the ability to link C code with IGRIP, thus allowing controllers to be developed, tested, and tuned in simulation and then ported directly to hardware systems using the C language.« less

  3. Concrete material characterization reinforced concrete tank structure Multi-Function Waste Tank Facility

    NASA Astrophysics Data System (ADS)

    Winkel, B. V.

    1995-03-01

    The purpose of this report is to document the Multi-Function Waste Tank Facility (MWTF) Project position on the concrete mechanical properties needed to perform design/analysis calculations for the MWTF secondary concrete structure. This report provides a position on MWTF concrete properties for the Title 1 and Title 2 calculations. The scope of the report is limited to mechanical properties and does not include the thermophysical properties of concrete needed to perform heat transfer calculations. In the 1970's, a comprehensive series of tests were performed at Construction Technology Laboratories (CTL) on two different Hanford concrete mix designs. Statistical correlations of the CTL data were later generated by Pacific Northwest Laboratories (PNL). These test results and property correlations have been utilized in various design/analysis efforts of Hanford waste tanks. However, due to changes in the concrete design mix and the lower range of MWTF operating temperatures, plus uncertainties in the CTL data and PNL correlations, it was prudent to evaluate the CTL data base and PNL correlations, relative to the MWTF application, and develop a defendable position. The CTL test program for Hanford concrete involved two different mix designs: a 3 kip/sq in mix and a 4.5 kip/sq in mix. The proposed 28-day design strength for the MWTF tanks is 5 kip/sq in. In addition to this design strength difference, there are also differences between the CTL and MWTF mix design details. Also of interest, are the appropriate application of the MWTF concrete properties in performing calculations demonstrating ACI Code compliance. Mix design details and ACI Code issues are addressed in Sections 3.0 and 5.0, respectively. The CTL test program and PNL data correlations focused on a temperature range of 250 to 450 F. The temperature range of interest for the MWTF tank concrete application is 70 to 200 F.

  4. Technology transfer personnel exchange at the Boeing Company

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Antoniak, Z.I.

    1993-03-01

    The objective of the exchange was to transfer Pacific Northwest Laboratory (PNL) technology and expertise in advanced ceramic fabric composites (ACFC) to the Boeing Defense & Space Group (Boeing Aerospace). Boeing Aerospace was especially interested in applying PNL-developed ACFC technology to its current and future spacecraft and space missions. Boeing has on-going independent research and development (R&D) programs on advanced radiators and heat pipes, therefore, PNL research in ceramic fabric heat pipes was of particular interest to Boeing. Thus, this exchange assisted in the transfer of PNL`s ACFC heat pipe technology and other, related research capabilities to private industrial application.more » The project was proposed as an initial step in building a long-term collaborative relationship between Boeing and PNL that may result in future Cooperative Research and Development Agreements (CRADAs) and/or other types of collaborative efforts.« less

  5. Technology transfer personnel exchange at the Boeing Company

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Antoniak, Z.I.

    1993-03-01

    The objective of the exchange was to transfer Pacific Northwest Laboratory (PNL) technology and expertise in advanced ceramic fabric composites (ACFC) to the Boeing Defense Space Group (Boeing Aerospace). Boeing Aerospace was especially interested in applying PNL-developed ACFC technology to its current and future spacecraft and space missions. Boeing has on-going independent research and development (R D) programs on advanced radiators and heat pipes, therefore, PNL research in ceramic fabric heat pipes was of particular interest to Boeing. Thus, this exchange assisted in the transfer of PNL's ACFC heat pipe technology and other, related research capabilities to private industrial application.more » The project was proposed as an initial step in building a long-term collaborative relationship between Boeing and PNL that may result in future Cooperative Research and Development Agreements (CRADAs) and/or other types of collaborative efforts.« less

  6. A Comparison of Retrograde Intrarenal Surgery and Percutaneous Nephrolithotomy for Management of Renal Stones ?2 CM.

    PubMed

    Sari, Sercan; Ozok, Hakki Ugur; Cakici, Mehmet Caglar; Ozdemir, Harun; Bas, Okan; Karakoyunlu, Nihat; Sagnak, Levent; Senturk, Aykut Bugra; Ersoy, Hamit

    2017-01-18

    In this retrospective study, we aimed to compare the outcomes in patients who have been treated withpercutaneous nephrolithotomy (PNL) and retrograde intrarenal surgery (RIRS) on renal stones ≥ 2 cm size. We evaluated patients who underwent PNL or RIRS for renal stones ≥ 2 cm size betweenNovember 2011 and November 2014. Stone size, operation, fluoroscopy and hospitalization time, success rates,stone-free rates and complication rates were compared in both groups. Patients were followed for three months. 254 patients were in the PNL Group. 185 patients were in the RIRS Group. The mean age was 46.88 and48.04 years in PNL and RIRS groups, respectively.The patient and stone characteristics (age, gender, Body Mass Index, kidney anomaly, SWL history and stoneradioopacity) were similar between two groups.The mean stone size preoperatively was significantly larger in patients who were treated with PNL (26.33mm.vs24.04mm.; P = .006). In the RIRS group, the mean stone number was significantly higher than PNL group (P <.001).The mean operative, fluoroscopy and hospitalization time were significantly higher in PNL group (P < .001). Thestone-free rate was 93.3% for the PNL group and 73.5% for the RIRS group after first procedure (P < .001). Nomajor complication (Clavien III-V) occurred in the RIRS group. Although the primary treatment method for renal stones ≥ 2cm size is PNL, serious complicationscan be seen. Therefore, RIRS can be an alternative treatment option in the management of renal stones ≥2 cm size.

  7. Process and Learning Outcomes from Remotely-Operated, Simulated, and Hands-on Student Laboratories

    ERIC Educational Resources Information Center

    Corter, James E.; Esche, Sven K.; Chassapis, Constantin; Ma, Jing; Nickerson, Jeffrey V.

    2011-01-01

    A large-scale, multi-year, randomized study compared learning activities and outcomes for hands-on, remotely-operated, and simulation-based educational laboratories in an undergraduate engineering course. Students (N = 458) worked in small-group lab teams to perform two experiments involving stress on a cantilever beam. Each team conducted the…

  8. Modified totally tubeless percutaneous nephrolithotomy: Is it an effective and safe treatment option for renal and upper ureteral stones?

    PubMed

    Chung, Ho Seok; Jung, Seung Il; Yu, Ho Song; Hwang, Eu Chang; Oh, Kyung Jin; Kwon, Dong Deuk; Park, Kwangsung

    2016-01-01

    We hypothesized that modified totally tubeless percutaneous nephrolithotomy (PNL) without indwelling ureteral stent would minimize postoperative discomfort without complications. To evaluate the safety, efficacy, and morbidity of standard, tubeless, and modified totally tubeless PNL as well as the usefulness of modified totally tubeless PNL. From November 2011 to February 2015, 211 patients who underwent PNL consecutively were enrolled in this study and divided into 3 groups (group 1: standard, group 2: tubeless, group 3: modified totally tubeless PNL). Patient and stone characteristics, operation time, hemoglobin change, length of hospitalization, stone-free rate, analgesic requirement, and perioperative complications were analyzed and compared among the 3 groups. There were no significant differences in preoperative patient characteristics among the three groups. In the postoperative analysis, the three groups had similar operation time, stone-free rate, perioperative fever and transfusion rate, but group 2 showed superior results in terms of length of hospitalization (p = 0.001). Group 2 and group 3 had a lower analgesic requirement (p = 0.010). Immediate postoperative hemoglobin change (p = 0.001) and tube site complications (p = 0.001) were more common in group 1. Modified totally tubeless PNL was not inferior in terms of postoperative outcomes and safety compared with the standard and tubeless PNL, and avoided the postoperative stent-related symptoms and cystoscopy for double-J stent removal. Modified totally tubeless PNL could be an alternative treatment of choice for management of renal or upper ureteral stones in selected patients.

  9. Routine operation of an Elliott 903 computer in a clinical chemistry laboratory

    PubMed Central

    Whitby, L. G.; Simpson, D.

    1973-01-01

    Experience gained in the last four years concerning the capabilities and limitations of an 8K Elliott 903 (18-bit word) computer with magnetic tape backing store in the routine operation of a clinical chemistry laboratory is described. Designed as a total system, routine operation has latterly had to be confined to data acquisition and process control functions, due primarily to limitations imposed by the choice of hardware early in the project. In this final report of a partially successful experiment the opportunity is taken to review mistakes made, especially at the start of the project, to warn potential computer users of pitfalls to be avoided. PMID:4580240

  10. Flexible Ureterorenoscopy versus Mini-Percutaneous Nephrolithotomy for the Treatment of Renal Stones.

    PubMed

    Ergin, Giray; Kirac, Mustafa; Kopru, Burak; Ebiloglu, Turgay; Biri, Hasan

    2018-04-22

    To compare the pain status and stone free rates of flexible ureterorenoscopy (F-URS) versus mini-percutaneousnephrolithotomy (mini-PNL) for the treatment of 1-to 2-cm renal stones. This study was retrospectively designed with match paired method. Between January 2013 and December 2016, 387 patients underwent stone surgery for renal stones, 45 patients underwent FURS and 45 patients underwent mini-PNL. 90 patients were divided into two groups according to the surgical procedures. Group 1 patients underwent F-URS, and Group 2 patients underwent mini-PNL. During the intraoperative andpostoperative periods, pain management for all patients was standardized. Pain scores were determined using a visual analogue scale (VAS) completed at 2, 6, 12 and 24 hours postoperatively. The stone free status, hemoglobin levels, fluoroscopy time (FT), operation time (OT), hospitalization time (HT), return to work time (RWT), and complications were noted for each patient. Of all patients, the mean age was 41.1 ± 12.1 years and the mean stone size was 13.9 ± 2.9 mm. The VAS scores were significantly higher in the mini-PNL group at 2, 6, 12 and 24 hours (P < .05). The stone-free status and complication rates were similar between the two groups (P > .05); however, the hemoglobin decreases and the fluoroscopy, operation, hospitalization and return to work times were higher in the mini-PNL group than in the F-URS group (P < .05). F-URS is less painful than mini-PNL for the treatment of 1- to 2-cm renal stones. However, the stone free rate is similar between the two procedures while mini-PNL is superior in terms of fluoroscopy, operation, hospitalization and return to work duration. We think that F-URS is more comfortable and less painful than mini-PNL and achieves a similar stone free rate for the treatment of 1- to 2-cm renal stones.

  11. Biological Assessment of the Continued Operation of Los Alamos National Laboratory on Federally Listed Threatened and Endangered Species

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hansen, Leslie A.

    2006-09-19

    This biological assessment considers the effects of continuing to operate Los Alamos National Laboratory on Federally listed threatened or endangered species, based on current and future operations identified in the 2006 Site-wide Environmental Impact Statement for the Continued Operation of Los Alamos National Laboratory (SWEIS; DOE In Prep.). We reviewed 40 projects analyzed in the SWEIS as well as two aspects on ongoing operations to determine if these actions had the potential to affect Federally listed species. Eighteen projects that had not already received U.S. Fish and Wildlife Service (USFWS) consultation and concurrence, as well as the two aspects ofmore » ongoing operations, ecological risk from legacy contaminants and the Outfall Reduction Project, were determined to have the potential to affect threatened or endangered species. Cumulative impacts were also analyzed.« less

  12. Vandenberg Air Force Base integrated resource assessment. Volume 3, Resource assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daellenbach, K.K.; Dagle, J.E.; Dittmer, A.L.

    1993-06-01

    The US Air Force Space Command (SPACECOM) has tasked the Pacific Northwest Laboratory (PNL), as the lead laboratory supporting the US Department of Energy (DOE) Federal Energy Management Program (FEMP), to identify, evaluate, and assist in acquiring all cost-effective energy projects at Vandenberg Air Force Base (VAFB). This is part of a model program that PNL is designing to support energy-use decisions in the federal sector. This report provides the results of the fossil fuel and electric energy resource opportunity (ERO) assessments performed by PNL at the SPACECOM VAFB facility located approximately 50 miles northwest of Santa Barbara, California. Itmore » is a companion report to Volume 1, Executive Summary, and Volume 2, Baseline Detail. The results of the analysis of EROs are presented in ten common energy end-use categories (e.g., boilers and furnaces, service hot water, and building lighting). In addition, a case study of process loads at Space Launch Complex-4 (SLC-4) is included. A narrative description of each ERO is provided, including information on the installed cost, energy and dollar savings; impacts on operation and maintenance (O and M); and, when applicable, a discussion of energy supply and demand, energy security, and environmental issues. A description of the evaluation methodologies and technical and cost assumptions is also provided for each ERO. Summary tables present the cost-effectiveness of energy end-use equipment before and after the implementation of each ERO and present the results of the life-cycle cost (LCC) analysis indicating the net present value (NPV) and value index (VI) of each ERO. Finally, an appendix includes a summary of an economic analysis case study of the South Vandenberg Power Plant (SVPP) operating scenarios.« less

  13. Comparative Study between Standard and Totally Tubeless Percutaneous Nephrolithotomy.

    PubMed

    Yun, Sung Il; Lee, Yoon Hyung; Kim, Jae Soo; Cho, Sung Ryong; Kim, Bum Soo; Kwon, Joon Beom

    2012-11-01

    Several recent studies have reported the benefits of tubeless percutaneous nephrolithotomy (PNL). Postoperatively, tubeless PNL patients have an indwelling ureteral stent placed, which is often associated with stent-related morbidity. We have performed totally tubeless (tubeless and stentless) PNL in which no nephrostomy tube or ureteral stent is placed postoperatively. We evaluated the safety, effectiveness, and feasibility of totally tubeless PNL. From March 2008 to February 2012, 57 selected patients underwent standard or totally tubeless PNL. Neither a nephrostomy tube nor a ureteral stent was placed in the totally tubeless PNL group. We compared patient and stone characteristics, operation time, length of hospitalization, analgesia requirements, stone-free rate, blood loss, change in creatinine, and perioperative complications between the standard and totally tubeless PNL groups. There were no significant differences in preoperative patient characteristics, postoperative complications, or the stone-free rate between the two groups, but the totally tubeless PNL group showed a shorter hospitalization and a lesser analgesic requirement compared with the standard PNL group. Blood loss and change in creatinine were not significantly different between the two groups. Totally tubeless PNL appears to be a safe and effective alternative for the management of renal stone patients and is associated with a decrease in length of hospital stay.

  14. Pacific Northwest Laboratory annual report for 1990 to the DOE Office of Energy Research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owczarski, E.L.

    At the start of FY 1990, the atmospheric sciences and carbon dioxide research programs within the Office of Health and Environmental Research (OHER) were gathered into the new Atmospheric and Climate Research Division (ACRD). One of the central missions of this new division is to provide the Department of Energy with scientifically defensible information on the local, regional, and global distributions of energy-related pollutants and their effects on climate. This information is vital to the definition and implementation of a sound national energy strategy. Because much of the work done at PNL during FY 1990 falls under the umbrella ofmore » the new ACRD, we are including in this volume the progress and status reports for all OHER atmospheric and climate research projects at PNL. The description of ongoing atmospheric and climate research at PNL is organized along two broad research areas; atmospheric research and climate research. This report describes the progress in FY 1990 in each of these areas. A divider page summarizes the goals of each area and lists projects that support research activities.« less

  15. An exploratory investigation of the translation of Pacific Northwest Laboratory's print manuals system to an on-line manuals system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heubach, J.G.; Hunt, S.T.; Pond, L.R.

    1992-06-01

    Information management technology has proliferated in the past decade in response to the information explosion. As documentation accumulates, the need to access information residing in manuals, handbooks and regulations conveniently, accurately, and quickly has increased. However, studies show that only fractions of the available information is read (Martin, 1978). Consequently, one of the biggest challenges in linking information and electronic management of information is to use the power of communication technology to meet the information needs of the audience. Pacific Northwest Laboratories' (PNL) investigation of translating its print manual system to an on-line system fits this challenge precisely. PNL's manualsmore » contain a tremendous amount of information for which manual holders are responsible. To perform their tasks in compliance with policy and procedure guidelines, users need to access information accurately, conveniently, and quickly. In order to select and use information management tools wisely, answers must be sought to a few basic questions. Communication experts cite four key questions: What do users want What do users need What characteristics of an on-line information system affect its usefulness Who are the users whose wants and needs are to be met Once these questions are answered, attention can be focused on finding the best match between user requirements and technology characteristics and weighing the costs and benefits of proposed options.« less

  16. The Software Engineering Laboratory: An operational software experience factory

    NASA Technical Reports Server (NTRS)

    Basili, Victor R.; Caldiera, Gianluigi; Mcgarry, Frank; Pajerski, Rose; Page, Gerald; Waligora, Sharon

    1992-01-01

    For 15 years, the Software Engineering Laboratory (SEL) has been carrying out studies and experiments for the purpose of understanding, assessing, and improving software and software processes within a production software development environment at NASA/GSFC. The SEL comprises three major organizations: (1) NASA/GSFC, Flight Dynamics Division; (2) University of Maryland, Department of Computer Science; and (3) Computer Sciences Corporation, Flight Dynamics Technology Group. These organizations have jointly carried out several hundred software studies, producing hundreds of reports, papers, and documents, all of which describe some aspect of the software engineering technology that was analyzed in the flight dynamics environment at NASA. The studies range from small, controlled experiments (such as analyzing the effectiveness of code reading versus that of functional testing) to large, multiple project studies (such as assessing the impacts of Ada on a production environment). The organization's driving goal is to improve the software process continually, so that sustained improvement may be observed in the resulting products. This paper discusses the SEL as a functioning example of an operational software experience factory and summarizes the characteristics of and major lessons learned from 15 years of SEL operations.

  17. CRADA with Beckman Instruments and Pacific Northwest National Laboratory (PNL-013): Development and commercialization of the Unsaturated Flow Apparatus (UFA) using characterization of aridisols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wright, J.; Conca, J.

    1996-10-01

    The objective of this Cooperative Research and Development Agreement (CRADA) was to develop and commercialize a technology conceived by scientists at Pacific Northwest National Laboratory (PNNL) and manufactured by Beckman Instruments, Inc. (Beckman), and to apply this technology to the characterization of and soils. The technology is the Unsaturated Flow Apparatus (UFA). The UFA provides a highly efficient method of direct, rapid measurement of hydraulic conductivity and other flow properties according to Darcy-Buckingham principles because the operator controls both the fluid driving force, using an ultracentrifuge, and the flow into the sample while it is spinning, with a rotating sealmore » assembly. The concept of using centrifugation to significantly decrease the time needed, from years or months to days, for study of subsurface transport, particularly under unsaturated conditions, was conceived by James Conca, Ph.D., and Judith Wright, Ph.D., in 1986. The prototype UFA was developed in 1988 because there was a need to rapidly and accurately determine transport parameters in soils, sediments, and rocks for the Grout Waste Disposal Program. Transport parameters are critical to modeling outcomes for site-specific solutions to environmental remediation and waste disposal problems.« less

  18. Ammonia and ammonium hydroxide sensors for ammonia/water absorption machines: Literature review and data compilation

    NASA Astrophysics Data System (ADS)

    Anheier, N. C., Jr.; McDonald, C. E.; Cuta, J. M.; Cuta, F. M.; Olsen, K. B.

    1995-05-01

    This report describes an evaluation of various sensing techniques for determining the ammonia concentration in the working fluid of ammonia/water absorption cycle systems. The purpose was to determine if any existing sensor technology or instrumentation could provide an accurate, reliable, and cost-effective continuous measure of ammonia concentration in water. The resulting information will be used for design optimization and cycle control in an ammonia-absorption heat pump. Pacific Northwest Laboratory (PNL) researchers evaluated each sensing technology against a set of general requirements characterizing the potential operating conditions within the absorption cycle. The criteria included the physical constraints for in situ operation, sensor characteristics, and sensor application. PNL performed an extensive literature search, which uncovered several promising sensing technologies that might be applicable to this problem. Sixty-two references were investigated, and 33 commercial vendors were identified as having ammonia sensors. The technologies for ammonia sensing are acoustic wave, refractive index, electrode, thermal, ion-selective field-effect transistor (ISFET), electrical conductivity, pH/colormetric, and optical absorption. Based on information acquired in the literature search, PNL recommends that follow-on activities focus on ISFET devices and a fiber optic evanescent sensor with a colormetric indicator. The ISFET and fiber optic evanescent sensor are inherently microminiature and capable of in situ measurements. Further, both techniques have been demonstrated selective to the ammonium ion (NH4(+)). The primary issue remaining is how to make the sensors sufficiently corrosion-resistant to be useful in practice.

  19. Modified totally tubeless percutaneous nephrolithotomy: Is it an effective and safe treatment option for renal and upper ureteral stones?

    PubMed Central

    Chung, Ho Seok; Yu, Ho Song; Hwang, Eu Chang; Oh, Kyung Jin; Kwon, Dong Deuk; Park, Kwangsung

    2016-01-01

    Introduction We hypothesized that modified totally tubeless percutaneous nephrolithotomy (PNL) without indwelling ureteral stent would minimize postoperative discomfort without complications. Aim To evaluate the safety, efficacy, and morbidity of standard, tubeless, and modified totally tubeless PNL as well as the usefulness of modified totally tubeless PNL. Material and methods From November 2011 to February 2015, 211 patients who underwent PNL consecutively were enrolled in this study and divided into 3 groups (group 1: standard, group 2: tubeless, group 3: modified totally tubeless PNL). Patient and stone characteristics, operation time, hemoglobin change, length of hospitalization, stone-free rate, analgesic requirement, and perioperative complications were analyzed and compared among the 3 groups. Results There were no significant differences in preoperative patient characteristics among the three groups. In the postoperative analysis, the three groups had similar operation time, stone-free rate, perioperative fever and transfusion rate, but group 2 showed superior results in terms of length of hospitalization (p = 0.001). Group 2 and group 3 had a lower analgesic requirement (p = 0.010). Immediate postoperative hemoglobin change (p = 0.001) and tube site complications (p = 0.001) were more common in group 1. Conclusions Modified totally tubeless PNL was not inferior in terms of postoperative outcomes and safety compared with the standard and tubeless PNL, and avoided the postoperative stent-related symptoms and cystoscopy for double-J stent removal. Modified totally tubeless PNL could be an alternative treatment of choice for management of renal or upper ureteral stones in selected patients. PMID:28194243

  20. Laboratory Information Systems.

    PubMed

    Henricks, Walter H

    2015-06-01

    Laboratory information systems (LISs) supply mission-critical capabilities for the vast array of information-processing needs of modern laboratories. LIS architectures include mainframe, client-server, and thin client configurations. The LIS database software manages a laboratory's data. LIS dictionaries are database tables that a laboratory uses to tailor an LIS to the unique needs of that laboratory. Anatomic pathology LIS (APLIS) functions play key roles throughout the pathology workflow, and laboratories rely on LIS management reports to monitor operations. This article describes the structure and functions of APLISs, with emphasis on their roles in laboratory operations and their relevance to pathologists. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Comparative Study between Standard and Totally Tubeless Percutaneous Nephrolithotomy

    PubMed Central

    Yun, Sung Il; Lee, Yoon Hyung; Kim, Jae Soo; Cho, Sung Ryong; Kim, Bum Soo

    2012-01-01

    Purpose Several recent studies have reported the benefits of tubeless percutaneous nephrolithotomy (PNL). Postoperatively, tubeless PNL patients have an indwelling ureteral stent placed, which is often associated with stent-related morbidity. We have performed totally tubeless (tubeless and stentless) PNL in which no nephrostomy tube or ureteral stent is placed postoperatively. We evaluated the safety, effectiveness, and feasibility of totally tubeless PNL. Materials and Methods From March 2008 to February 2012, 57 selected patients underwent standard or totally tubeless PNL. Neither a nephrostomy tube nor a ureteral stent was placed in the totally tubeless PNL group. We compared patient and stone characteristics, operation time, length of hospitalization, analgesia requirements, stone-free rate, blood loss, change in creatinine, and perioperative complications between the standard and totally tubeless PNL groups. Results There were no significant differences in preoperative patient characteristics, postoperative complications, or the stone-free rate between the two groups, but the totally tubeless PNL group showed a shorter hospitalization and a lesser analgesic requirement compared with the standard PNL group. Blood loss and change in creatinine were not significantly different between the two groups. Conclusions Totally tubeless PNL appears to be a safe and effective alternative for the management of renal stone patients and is associated with a decrease in length of hospital stay. PMID:23185671

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    King, A.G.

    The Pacific Northwest Laboratory (PNL)/Analytical Chemistry Laboratory (ACL) and the Westinghouse Hanford Company (WHC)/Process Analytical Laboratory (PAL) provide analytical support services to various environmental restoration and waste management projects/programs at Hanford. In response to a US Department of Energy -- Richland Field Office (DOE-RL) audit, which questioned the comparability of analytical methods employed at each laboratory, the Sample Exchange/Exchange (SEE) program was initiated. The SEE Program is a selfassessment program designed to compare analytical methods of the PAL and ACL laboratories using sitespecific waste material. The SEE program is managed by a collaborative, the Quality Assurance Triad (Triad). Triad membershipmore » is made up of representatives from the WHC/PAL, PNL/ACL, and WHC Hanford Analytical Services Management (HASM) organizations. The Triad works together to design/evaluate/implement each phase of the SEE Program.« less

  3. The ideal laboratory information system.

    PubMed

    Sepulveda, Jorge L; Young, Donald S

    2013-08-01

    Laboratory information systems (LIS) are critical components of the operation of clinical laboratories. However, the functionalities of LIS have lagged significantly behind the capacities of current hardware and software technologies, while the complexity of the information produced by clinical laboratories has been increasing over time and will soon undergo rapid expansion with the use of new, high-throughput and high-dimensionality laboratory tests. In the broadest sense, LIS are essential to manage the flow of information between health care providers, patients, and laboratories and should be designed to optimize not only laboratory operations but also personalized clinical care. To list suggestions for designing LIS with the goal of optimizing the operation of clinical laboratories while improving clinical care by intelligent management of laboratory information. Literature review, interviews with laboratory users, and personal experience and opinion. Laboratory information systems can improve laboratory operations and improve patient care. Specific suggestions for improving the function of LIS are listed under the following sections: (1) Information Security, (2) Test Ordering, (3) Specimen Collection, Accessioning, and Processing, (4) Analytic Phase, (5) Result Entry and Validation, (6) Result Reporting, (7) Notification Management, (8) Data Mining and Cross-sectional Reports, (9) Method Validation, (10) Quality Management, (11) Administrative and Financial Issues, and (12) Other Operational Issues.

  4. Laboratory Heterodyne Spectrometers Operating at 100 and 300 GHZ

    NASA Astrophysics Data System (ADS)

    Maßen, Jakob; Wehres, Nadine; Hermanns, Marius; Lewen, Frank; Heyne, Bettina; Endres, Christian; Graf, Urs; Honingh, Netty; Schlemmer, Stephan

    2017-06-01

    Two new laboratory heterodyne emission spectrometers are presented that are currently used for high-resolution rotational spectroscopy of complex organic molecules. The room temperature heterodyne receiver operating between 80-110 GHz, as well as the SIS heterodyne receiver operating between 270-370 GHz allow access to two very important frequency regimes, coinciding with Bands 3 and 7 of the ALMA (Atacama Large Millimeter Array) telescope. Taking advantage of recent progresses in the field of mm/submm technology, we build these two spectrometers using an XFFFTS (eXtended Fast Fourier Transform Spectrometer) for spectral acquisition. The instantaneous bandwidth is 2.5 GHz in a single sideband, spread over 32768 channels. Thus, the spectral resolution is about 76 kHz per channel and thus comparable to high resolution spectra from telescopes. Both receivers are operated in double sideband mode resulting in a total instantaneous bandwidth of 5 GHz. The system performances, in particular the noise temperatures and stabilities are presented. Proof-of-concept is demonstrated by showing spectra of methyl cyanide obtained with both spectrometers. While the transition frequencies for this molecule are very well known, intensities of those transitions can also be determined with high accuracy using our new instruments. This additional information shall be exploited in future measurements to improve spectral predictions for astronomical observations. Other future prospects concern the study of more complex organic species, such as ethyl cyanide. These aspects of the new instruments as well as limitations of the two distinct receivers will be discussed.

  5. [Study on the immunization status and its influencing factors among workers from the polio network laboratories in China].

    PubMed

    Guo, Y S; Wang, J Q; Xu, C; Liu, Y N; He, X H; Wei, Q

    2017-06-10

    Objective: To Investigate the immune status and influencing factors of provincial polio network laboratory (PNL) workers in China so as to provide evidence for the development of related strategies to protect personnel working at the PNLs. Methods: All the practitioners from the PNLs at the provincial centers for disease control, were selected as objects for this study, from October to December, 2016, under a questionnaire survey. Information on status of immunity and influencing factors was collected, with SAS software, trend chi-square used for statistics analysis. Results: A total of 77 workers were involved in this survey, with 60 (78 % ) of them completed the polio-based immune program but the rest 17 (22 % ) remained records unclear. 66 people (about 86 % ) remembered clearly that they had received vaccination when engaging in the polio-lab work, but the rest 11 (14 % ) with only partial vaccination records. We also noticed that the Influencing factors realted to vaccination status were: age ( χ (2)=2.48, P <0.05), title ( χ (2)=2.51, P <0.05), years of employment ( P <0.000 1), education ( χ (2)=0.74, P =0.46) and gender ( χ (2)=0.46, P =0.50). Conclusion: Immune status of the Chinese provincial PNL practitioners appeared fairly good as 86 % of all the workers had received polio-related vaccination, with 41 % of them completed a 3-time inoculation program, when started working in this field.

  6. Thermal Performance of the Mars Science Laboratory Rover During Mars Surface Operations

    NASA Technical Reports Server (NTRS)

    Novak, Keith S.; Kempenaar, Joshua E.; Liu, Yuanming; Bhandari, Pradeep; Lee, Chern-Jiin

    2013-01-01

    On November 26, 2011, NASA launched a large (900 kg) rover as part of the Mars Science Laboratory (MSL) mission to Mars. Eight months later, on August 5, 2012, the MSL rover (Curiosity) successfully touched down on the surface of Mars. As of the writing of this paper, the rover had completed over 200 Sols of Mars surface operations in the Gale Crater landing site (4.5 deg S latitude). This paper describes the thermal performance of the MSL Rover during the early part of its two Earth-0.year (670 Sols) prime surface mission. Curiosity landed in Gale Crater during early Spring (Ls=151) in the Southern Hemisphere of Mars. This paper discusses the thermal performance of the rover from landing day (Sol 0) through Summer Solstice (Sol 197) and out to Sol 204. The rover surface thermal design performance was very close to pre-landing predictions. The very successful thermal design allowed a high level of operational power dissipation immediately after landing without overheating and required a minimal amount of survival heating. Early morning operations of cameras and actuators were aided by successful heating activities. MSL rover surface operations thermal experiences are discussed in this paper. Conclusions about the rover surface operations thermal performance are also presented.

  7. Thermal Performance of the Mars Science Laboratory Rover During Mars Surface Operations

    NASA Technical Reports Server (NTRS)

    Novak, Keith S.; Kempenaar, Joshua E.; Liu, Yuanming; Bhandari, Pradeep; Lee, Chern-Jiin

    2013-01-01

    On November 26, 2011, NASA launched a large (900 kg) rover as part of the Mars Science Laboratory (MSL) mission to Mars. Eight months later, on August 5, 2012, the MSL rover (Curiosity) successfully touched down on the surface of Mars. As of the writing of this paper, the rover had completed over 200 Sols of Mars surface operations in the Gale Crater landing site (4.5 degrees South latitude). This paper describes the thermal performance of the MSL Rover during the early part of its two Earth-0.year (670 Sols) prime surface mission. Curiosity landed in Gale Crater during early Spring (Solar longitude=151) in the Southern Hemisphere of Mars. This paper discusses the thermal performance of the rover from landing day (Sol 0) through Summer Solstice (Sol 197) and out to Sol 204. The rover surface thermal design performance was very close to pre-landing predictions. The very successful thermal design allowed a high level of operational power dissipation immediately after landing without overheating and required a minimal amount of survival heating. Early morning operations of cameras and actuators were aided by successful heating activities. MSL rover surface operations thermal experiences are discussed in this paper. Conclusions about the rover surface operations thermal performance are also presented.

  8. A Methodical Approach to the Creation, Operation, and Enhancement of a General-use Microcomputer Laboratory.

    ERIC Educational Resources Information Center

    Seilheimer, Steven D.

    1988-01-01

    Outlines procedures for developing a microcomputer laboratory for use by students in an academic organization, based on experiences at Niagara University. The four phases described include: (1) needs assessment; (2) establishment, including software and hardware selection and physical facilities; (3) operation, including staffing, maintenance,…

  9. Totally tubeless percutaneous nephrolithotomy is feasible in morbidly obese patients.

    PubMed

    Aghamir, Seyed Mohammad Kazem; Mohseni, Mohammad Ghasem; Hosseini, Seyed Reza; Salavati, Alborz; Ganjali, Hossein; Fallah, Mohammad Ali; Rezaei, Hamed; Modaresi, Seyed Saeed

    2017-06-01

    Regarding technical difficulties that obese body habitus might impose to percutaneous nephrolithotomy (PNL) success and higher risk of peri-operative complications in this group of patients, we decided to retrospectively gather data from our patients during past 8 years to determine the stone free and complication rates. Between January 2007-December 2015, seventy-eight obese patients with body mass index over 35 who had indication for PNL including stones larger than 2 cm in pelvi-calyceal system or smaller extracorporeal shock wave lithotripsy (ESWL) resistant stones or who were not a fit candidate for ESWL due to increased skin to target distance, with no contraindication of PNL (including bleeding diathesis, inability to be positioned in prone) were enrolled. They were randomly assigned to group 1 (standard PNL with nephrostomy and ureteral stent) or group 2 (totally tubeless PNL with no ureteral stent and no nephrostomy). The outcomes were compared. The transfusion rate, operation time, and the hemoglobin drop were same across the groups (p>0.05). Total analgesic use was equivalent of 33.8 vs. 14.7 mgs of morphine sulfate (18-77 mg) and was significantly lower in total tubeless group (p=0.001). Return to normal activity was described as total number of in-patient and outpatient days from time of admission to the point which the patients returns to normal life activity such as going to job or school and was 19.4 vs. 9.3 days (6-30 days, p=0.001). Totally tubeless PNL in obese subjects would have lower analgesic use and return to normal activity versus standard PNL. Totally tubeless PNL is recommended for obese patients.

  10. A combined field and laboratory design for assessing the impact of night shift work on police officer operational performance.

    PubMed

    Waggoner, Lauren B; Grant, Devon A; Van Dongen, Hans P A; Belenky, Gregory; Vila, Bryan

    2012-11-01

    This study assessed the utility of a combined field and laboratory research design for measuring the impact of consecutive night shift work on the sleepiness, vigilance, and driving performance of police patrol officers. For police patrol officers working their normal night shift duty cycles, simulated driving performance and psychomotor vigilance were measured in a laboratory on two separate occasions: in the morning after the last of five consecutive 10.7-h night shifts, and at the same time in the morning after three consecutive days off duty. Order of participation in conditions was randomized among subjects. Subjects experienced manipulation of sleep schedules due to working night shifts in a real operational environment, but performance testing was conducted under controlled laboratory conditions. N = 29 active-duty police patrol officers (27 male, 2 female; age 37.1 ± 6.3 years) working night shift schedules participated in this study. Simulated driving performance, psychomotor vigilance, and subjective sleepiness were significantly degraded following 5 consecutive night shifts as compared to 3 consecutive days off duty, indicating that active-duty police officers are susceptible to performance degradation as a consequence of working nights. This combined field and laboratory research design succeeded in bridging the gap between the realism of the operational environment and the control of laboratory performance testing, demonstrating that this is a useful approach for addressing the relationship between shift work induced fatigue and critical operational task performance.

  11. Intrarenal Surgery vs Percutaneous Nephrolithotomy in the Management of Lower Pole Stones Greater than 2 cm.

    PubMed

    Koyuncu, Hakan; Yencilek, Faruk; Kalkan, Mehmet; Bastug, Yavuz; Yencilek, Esin; Ozdemir, Ahmet Tunc

    2015-01-01

    To compare the efficacy of RIRS and PNL in lower pole stones ≥ 2 cm. Materials and and Methods: A total of 109 patients who underwent PNL or RIRS for solitary lower pole stone between April 2009 and December 2012, were retrospectively analyzed. Lower pole stone was diagnosed with CT scan. Stone size was assessed as the longest axis of the stone. All patients were informed about the advantages, disadvantages and probable complications of both PNL and RIRS before the selection of the procedure. Patients decided the surgery type by themselves without being under any influences and written informed consent was obtained from all patients prior to the surgery. Patients were divided into two groups according to the patients' preference of surgery type. Group 1 consisted of 77 patients who underwent PNL and Group 2 consisted of 32 patients treated with RIRS. Stone free statuses, postoperative complications, operative time and hospitalization time were compared in both groups. There was no statistical significance between the two groups in mean age, stone size, stone laterality, mean follow-up periods and mean operative times. In PNL group, stone-free rate was 96.1% at first session and 100% after the additional procedure. In Group 2, stone-free rate was 90.6% at the first procedure and 100% after the additional procedure. The final stone-free rates and operative times were similar in both groups. RIRS should be an effective treatment alternative to PNL in lower pole stones larger than 2 cm, especially in selected patients.

  12. Factors Influencing Complications of Percutaneous Nephrolithotomy: A Single-Center Study.

    PubMed

    Oner, Sedat; Okumus, Muhammed Masuk; Demirbas, Murat; Onen, Efe; Aydos, Mustafa Murat; Ustun, Mehmet Hakan; Kilic, Metin; Avci, Sinan

    2015-11-14

    Percutaneous nephrolithotomy (PNL) is a minimally invasive procedure used for successful treatment of renal calculi. However, it is associated with various complications. We assessed the complications and their potential influencing factors in patients who had undergone PNL. In total, 1750 patients who had undergone PNL from November 2003 to June 2011 were evaluated retrospectively. PNL complications and possible contributing risk factors (age, sex, serum creatinine level, previous operations, hydronephrosis, calculi size, localization, opacity, surgeon's experience, accessed calyxes, number of accesses, and costal entries) were determined. Receiver operating characteristic (ROC) analysis was used to investigate the cutoff values of the data. Ideal cutoff value was determined by Youden's J statistic. All the demographic and clinical variables were examined using backward stepwise logistical regression analysis. Continuous variables were categorized with logistic regression analysis according to the cutoff values. Complications occurred in 396 (24.4%) patients who had undergone PNL. Hemorrhage requiring blood transfusion occurred in 221 (12.6%) patients, hemorrhage requiring arterial embolization occurred in 7 (0.4%) patients, perirenal hematoma occurred in 17 (0.97%) patients, hemo-pneumothorax occurred in 32 (1.8%) patients, and colon perforation occurred in 4 (0.22%) patients. Three patients (0.06%) died of severe urosepsis, and one patient (0.02%) died of severe bleeding. The calculus size, localization, access site, number of accesses, presence of staghorn stones, surgeon's experience, and duration of the operation significantly affected the complication risk. Our retrospective evaluation of this large patient series reveals that, PNL is a very effective treatment modality for kidney stones. However, although rare, serious complications including death can occur.

  13. Intrarenal Surgery vs Percutaneous Nephrolithotomy in the Management of Lower Pole Stones Greater than 2 cm

    PubMed Central

    Koyuncu, Hakan; Yencilek, Faruk; Kalkan, Mehmet; Bastug, Yavuz; Yencilek, Esin; Ozdemir, Ahmet Tunc

    2015-01-01

    Purpose To compare the efficacy of RIRS and PNL in lower pole stones ≥2 cm. Materials and and Methods: A total of 109 patients who underwent PNL or RIRS for solitary lower pole stone between April 2009 and December 2012, were retrospectively analyzed. Lower pole stone was diagnosed with CT scan. Stone size was assessed as the longest axis of the stone. All patients were informed about the advantages, disadvantages and probable complications of both PNL and RIRS before the selection of the procedure. Patients decided the surgery type by themselves without being under any influences and written informed consent was obtained from all patients prior to the surgery. Patients were divided into two groups according to the patients’ preference of surgery type. Group 1 consisted of 77 patients who underwent PNL and Group 2 consisted of 32 patients treated with RIRS. Stone free statuses, postoperative complications, operative time and hospitalization time were compared in both groups. Results There was no statistical significance between the two groups in mean age, stone size, stone laterality, mean follow-up periods and mean operative times. In PNL group, stone-free rate was 96.1% at first session and 100% after the additional procedure. In Group 2, stone-free rate was 90.6% at the first procedure and 100% after the additional procedure. The final stone-free rates and operative times were similar in both groups. Conclusions RIRS should be an effective treatment alternative to PNL in lower pole stones larger than 2 cm, especially in selected patients. PMID:26005965

  14. The Observation of Fault Finiteness and Rapid Velocity Variation in Pnl Waveforms for the Mw 6.5, San Simeon, California Earthquake

    NASA Astrophysics Data System (ADS)

    Konca, A. O.; Ji, C.; Helmberger, D. V.

    2004-12-01

    We observed the effect of the fault finiteness in the Pnl waveforms from regional distances (4° to 12° ) for the Mw6.5 San Simeon Earthquake on 22 December 2003. We aimed to include more of the high frequencies (2 seconds and longer periods) than the studies that use regional data for focal solutions (5 to 8 seconds and longer periods). We calculated 1-D synthetic seismograms for the Pn_l portion for both a point source, and a finite fault solution. The comparison of the point source and finite fault waveforms with data show that the first several seconds of the point source synthetics have considerably higher amplitude than the data, while finite fault does not have a similar problem. This can be explained by reversely polarized depth phases overlapping with the P waves from the later portion of the fault, and causing smaller amplitudes for the beginning portion of the seismogram. This is clearly a finite fault phenomenon; therefore, can not be explained by point source calculations. Moreover, the point source synthetics, which are calculated with a focal solution from a long period regional inversion, are overestimating the amplitude by three to four times relative to the data amplitude, while finite fault waveforms have the similar amplitudes to the data. Hence, a moment estimation based only on the point source solution of the regional data could have been wrong by half of magnitude. We have also calculated the shifts of synthetics relative to data to fit the seismograms. Our results reveal that the paths from Central California to the south are faster than to the paths to the east and north. The P wave arrival to the TUC station in Arizona is 4 seconds earlier than the predicted Southern California model, while most stations to the east are delayed around 1 second. The observed higher uppermost mantle velocities to the south are consistent with some recent tomographic models. Synthetics generated with these models significantly improves the fits and the

  15. Skylab mobile laboratory

    NASA Technical Reports Server (NTRS)

    Primeaux, G. R.; Larue, M. A.

    1975-01-01

    The Skylab mobile laboratory was designed to provide the capability to obtain necessary data on the Skylab crewmen 30 days before lift-off, within 1 hour after recovery, and until preflight physiological baselines were reattained. The mobile laboratory complex consisted of six laboratories that supported cardiovascular, metabolic, nutrition and endocrinology, operational medicine, blood, and microbiology experiments; a utility package; and two shipping containers. The objectives and equipment requirements of the Skylab mobile laboratory and the data acquisition systems are discussed along with processes such as permanently mounting equipment in the individual laboratories and methods of testing and transporting the units. The operational performance, in terms of amounts of data collected, and the concept of mobile laboratories for medical and scientific experiments are evaluated. The Skylab mobile laboratory succeeded in facilitating the data collection and sample preservation associated with the three Skylab manned flights.

  16. Current operator volumes of invasive coronary procedures in Medicare patients: implications for future manpower needs in the catheterization laboratory.

    PubMed

    Maroney, Justin; Khan, Saba; Powell, Wayne; Klein, Lloyd W

    2013-01-01

    We seek to assess the per-operator volume of diagnostic catheterizations and percutaneous coronary interventions (PCI) among US cardiologists, and its implication for future manpower needs in the catheterization laboratory. The number of annual Medicare PCIs peaked in 2004 and has trended downward since, however the total number of catheterization laboratories nationwide has increased. It is unknown whether these trends have resulted in a dilution of per-operator volumes, and whether the current supply of interventional cardiologists is appropriate to meet future needs. We analyzed the Centers for Medicare and Medicaid Services 2008 Medicare 5% sample file, and extracted the total number of Medicare fee-for-service (Medicare FFS) diagnostic catheterizations and PCIs performed in 2008. We then determined per-physician procedure volumes using National Provider Identifier numbers. There were 1,198,610 Medicare FFS diagnostic catheterizations performed by 11,029 diagnostic cardiologists, and there were 378,372 Medicare FFS PCIs performed by 6,443 interventional cardiologists in 2008. The data reveal a marked difference in the 2008 distribution of diagnostic catheterizations and PCIs among operators. Just over 10% of diagnostic catheterizations were performed by operators performing 40 or fewer Medicare FFS diagnostic catheterizations, contrasted with almost 30% of PCIs performed by operators with 40 of fewer Medicare FFS PCIs. A significant majority of interventional cardiologists (61%) performed 40 or fewer Medicare FFS PCIs in 2008. There is a high percentage of low-volume operators performing PCI, raising questions regarding annual volume recommendations for procedural skill maintenance, and the future manpower requirements in the catheterization laboratory. Copyright © 2012 Wiley Periodicals, Inc.

  17. Efficacy of surgical techniques and factors affecting residual stone rate in the treatment of kidney stones.

    PubMed

    Aydemir, Hüseyin; Budak, Salih; Kumsar, Şükrü; Köse, Osman; Sağlam, Hasan Salih; Adsan, Öztuğ

    2014-09-01

    In this study, we aimed to evaluate, the efficacy of surgical methods and the factors affecting the residual stone rate by scrutinizing retrospectively the patients who had undergone renal stone surgery. Records of 109 cases of kidney stones who had been surgically treated between January 2010, and July 2013 were reviewed. Patients were divided into three groups in terms of surgical treatment; open stone surgery, percutaneous nephrolithotomy (PNL) and retrograde intrarenal surgery (RIRS). Patients' history, physical examination, biochemical and radiological images and operative and postoperative data were recorded. The patients had undergone PNL (n=74; 67.9%), RIRS (n=22;20.2%), and open renal surgery (n=13; 11.9%). The mean and median ages of the patients were 46±9, 41 (21-75) and, 42 (23-67) years, respectively. The mean stone burden was 2.6±0.7 cm(2) in the PNL, 1.4±0.1 cm(2) in the RIRS, and 3.1±0.9 cm(2) in the open surgery groups. The mean operative times were 126±24 min in the PNL group, 72±12 min in the RIRS group and 82±22 min in the open surgery group. The duration of hospitalisation was 3.1±0.2 days, 1.2±0.3 days and 3.4±1.1 days respectively. While the RIRS group did not need blood transfusion, in the PNL group blood transfusions were given in the PNL (n=18), and open surgery (n=2) groups. Residual stones were detected in the PNL (n=22), open surgery (n=2), and RIRS (n=5) groups. PNL and RIRS have been seen as safe and effective methods in our self application too. However, it should not be forgotten that as a basical method, open surgery may be needed in cases of necessity.

  18. Percutaneous Nephrolithotomy in Autosomal Dominant Polycystic Kidney Disease: Is it Different from Percutaneous Nephrolithotomy in Normal Kidney?

    PubMed

    Singh, Vishwajeet; Sinha, Rahul Janak; Gupta, Dheeraj Kumar

    2013-08-01

    Nephrolithiasis has been reported in 20-28% of patients, of whom 50% are symptomatic for stone disease and 20% require definite urologic intervention. The management of nephrolithiasis includes oral alkali dissolution therapy, extracorporeal shock wave lithotripsy and surgical treatment. In such patients, percutaneous nephrolithotomy (PNL) as a method of stone treatment has been reported in few cases with limited experience. The aim of this study is to present our experience of PNL in autosomal dominant polycystic kidney disease (ADPKD) and assessing the outcome results. From 2002 to 2011, 22 patients (26 renal units) suffering from ADPKD with stone were managed by PNL. Demographic characteristics, operative parameters and postoperative complications were recorded and analysed. The overall success rate of PNL was 82.1% and PNL with extracorporeal shock wave lithotripsy for clinically significant residual fragments was 92.85% respectively. The hematuria required blood transfusion (n = 9), postoperative fever due to cyst infection (n = 4) and paralytic ileus (n = 3) were recorded. The PNL in ADPKD PNL is safe and effective but have more postoperative complications such as bleeding requiring transfusions, fever due to cyst infection and paralytic ileus.

  19. Totally tubeless percutaneous nephrolithotomy: is it safe and effective in preschool children?

    PubMed

    Ozturk, Ahmet; Guven, Selcuk; Kilinc, Mehmet; Topbaş, Emrah; Piskin, Mesut; Arslan, Mehmet

    2010-12-01

    After the introduction of tubeless percutaneous nephrolithotomy (PNL), many studies conducted in adult patients have confirmed its efficacy and safety. There are limited studies reporting that tubeless PNL can be safely applied in children, however. Furthermore, there are no reports that evaluate the use of totally tubeless PNL in children. The present study evaluates the results of totally tubeless PNL in preschool children. The data of children seen in our clinic who were considered suitable for totally tubeless PNL were analyzed. Of 16 children, 8 patients underwent totally tubeless PNL (group 1) and 8 standard PNL (group 2). The two groups of patients were compared with regard to length of hospitalization, analgesic requirements, transfusion rates, hemoglobin (Hb) decrease, and immediate, early, and late complications. The mean ages of the patients were 56.6 months (9-84 mos) and 56.0 months (5-84 mos), and the mean follow-up was 21.5 months (3-44 mos) and 43.4 months (36-54 mos) in groups 1 and 2, respectively. Both groups were similar with regard to age, stone size, Hb change, and complications. Although operation duration, hospitalization period, and analgesic requirement were less in the totally tubeless PNL group, these differences were not statistically significant. The latest application of PNL, totally tubeless PNL, is also a safe and effective procedure in very small children if they are selected properly and if the surgeon has sufficient experience with the procedure. More studies with a higher number of participants are needed, however, to confirm that totally tubeless PNL increases the comfort of pediatric patients, decreases their hospitalization period, and is more economical.

  20. [The pilot program in Mexican clinical laboratories. II. The characterization of the operating processes].

    PubMed

    de Gortari, E; Herrera, M; Loría, A; Terrés, A; González-Salayandia, M A; Hernández, M A

    1994-01-01

    To evaluate a questionnaire for operating procedures in Mexican clinical laboratories. A group of 18 hospital laboratories (described in the first paper of this series). The questionnaire had 132 items exploring nine sections (bacteriology, clinical chemistry, general hematology, immunology, microbacteriology, mycology, parasitology and urine analysis) and it was filled by the participants and modified if necessary in an audit visit. The questions were scored in the range of zero to one, and the participants in a scale of zero to 100 points. the answers had scores ranging from zero (N = 3) to one (N = 11) and a distribution with a clear shift to high scores. This led to a partition in three categories (low: < 0.3, medium: 03.-0.7, high: > 0.7) and to calculate a low/high ratio which enabled us to identify poor procedures in the sections. This ratio was also used to evaluate the type of procedure involved, i.e. management (N = 51), resources (N = 36), quality control (N = 23), and type and number of tests performed (N = 16). In the evaluation of the laboratories, the global score was 60. As expected, the private laboratories had the highest scores (73 to 84) as they were chosen because of their good resources. In the public ones only the State laboratories had more members above the mean score than below, whereas most of the Federal laboratories were below the global mean. The questionnaire performed reasonably well in spite of some deficiencies, i.e. it should include more questions on the specialized sections and on procedures other than management. The specialized sections (immunology, microbacteriology, mycology and parasitology) had lower scores than the more traditional ones (chemistry, hematology and bacteriology). Resources and quality control had lower scores than management; and the laboratory scores of the auditors tended to be lower than the autoevaluation of the public hospitals.

  1. Maintenance and operation of the multispectral data collection and reproduction facilities of the Willow Run Laboratories

    NASA Technical Reports Server (NTRS)

    Hasell, P. G., Jr.; Stewart, S. R.

    1972-01-01

    The accomplishments in multispectral mapping during 1970 and (fiscal year) 1971 are presented. The mapping was done with the instrumented C-47 aircraft owned and operated by Willow Run Laboratories of The University of Michigan. Specific information for flight operations sponsored by NASA/MSC (Manned Spacecraft Center) in 1970 and fiscal year 1971 is presented, and a total listing of flights for 1968, 1969, 1970, and fiscal year 1971 is included in the appendices. The data-collection and reproduction facilities are described.

  2. The CGE-PLATO Electronic Laboratory Station Structure and Operation.

    ERIC Educational Resources Information Center

    Neal, J. P.

    An electronic laboratory station was designed for student use in learning electronic instrumentation and measurement by means of the computer-guided experimentation (CGE) system. The station features rack-mounted electronic laboratory equipment on a laboratory table adjacent to a PLATO IV terminal. An integrated logic system behind the laboratory…

  3. Conclusions drawn from actions implemented within the first stage of the Cracow program of energy conservation and clean fossil fuels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bieda, J.; Bardel, J.; Pierce, B.

    1995-12-31

    Since 1992 Brookhaven National Laboratory (BNL) and Pacific Northwest Laboratory (PNL), acting on behalf of the U.S. Department of Energy, executed the first stage of the Cracow Program of Energy Conservation and Clean Fossil Fuels, called also American-Polish Program of Actions for Elimination of Low Emission Sources in Cracow. The main contractor for BNL and PNL was the Cracow Development Office (BRK). The interest in improving the condition of Cracow air results from the fact that the standard for permissible air pollution was exceeded several times in Cracow and especially within the central part of the town. Therefore, air pollutionmore » appeared one of the most important problems that faced the municipal authorities. It followed from monitoring investigations that the high level of air pollutant concentration is caused by in-home coal-fired tile stoves operated in winter seasons and by coal- and coke-fired boiler houses simulated mainly in the central part of the town. The results obtained in first stage are presented. This paper is an attempt to formulate conclusions drawn from these works and recommendations with regard to the future policy of the town authorities; selected results are presented to clarify or illustrate the conclusions.« less

  4. Impact of stone branch number on outcomes of percutaneous nephrolithotomy for treatment of staghorn calculi.

    PubMed

    Qi, Shiyong; Li, Li; Liu, Ranlu; Qiao, Baomin; Zhang, Zhihong; Xu, Yong

    2014-02-01

    To determine the impact of staghorn calculi branch number on outcomes of percutaneous nephrolithotomy (PNL). Retrospectively, we evaluated 371 patients (386 renal units) who underwent PNL for staghorn calculi. All calculi were showed with CT three-dimensional reconstruction (3DR) imaging preoperatively. From 3DR images, the number of stone branching into minor renal calices was recorded. According to the number, patients were divided into four groups. Group 1: the branch number 2-4; Group 2: the branch number 5-7; Group 3: the branch number 8-10; Group 4: the branch number >10. The number of percutaneous tract, operative time, staged PNL, intraoperative blood loss, postoperative hospital stay, complications, main stone composition, and stone clearance rate were compared. A significantly higher ratio of multitract (p<0.001) and staged PNL (p<0.001), a longer operative time (p<0.001) and postoperative hospital stay (p=0.043), and a lower rate of stone clearance (p<0.05) were found in PNL for calculi with a stone branch number ≥5. There was no statistical difference in intraoperative blood loss (p=0.101) and main stone composition (p=0.546). There was no statistically meaningful difference among the four groups based on the Clavien complication system (p=0.46). With the stone branch number more than five, the possibility of multitract and staged PNL, lower rate of stone clearance, and a longer postoperative hospital stay increases for staghorn calculi.

  5. Use of the LITEE Lorn Manufacturing Case Study in a Senior Chemical Engineering Unit Operations Laboratory

    ERIC Educational Resources Information Center

    Abraham, Nithin Susan; Abulencia, James Patrick

    2011-01-01

    This study focuses on the effectiveness of incorporating the Laboratory for Innovative Technology and Engineering Education (LITEE) Lorn Manufacturing case into a senior level chemical engineering unit operations course at Manhattan College. The purpose of using the case study is to demonstrate the relevance of ethics to chemical engineering…

  6. Assessment of environments for Mars Science Laboratory entry, descent, and surface operations

    USGS Publications Warehouse

    Vasavada, Ashwin R.; Chen, Allen; Barnes, Jeffrey R.; Burkhart, P. Daniel; Cantor, Bruce A.; Dwyer-Cianciolo, Alicia M.; Fergason, Robini L.; Hinson, David P.; Justh, Hilary L.; Kass, David M.; Lewis, Stephen R.; Mischna, Michael A.; Murphy, James R.; Rafkin, Scot C.R.; Tyler, Daniel; Withers, Paul G.

    2012-01-01

    The Mars Science Laboratory mission aims to land a car-sized rover on Mars' surface and operate it for at least one Mars year in order to assess whether its field area was ever capable of supporting microbial life. Here we describe the approach used to identify, characterize, and assess environmental risks to the landing and rover surface operations. Novel entry, descent, and landing approaches will be used to accurately deliver the 900-kg rover, including the ability to sense and "fly out" deviations from a best-estimate atmospheric state. A joint engineering and science team developed methods to estimate the range of potential atmospheric states at the time of arrival and to quantitatively assess the spacecraft's performance and risk given its particular sensitivities to atmospheric conditions. Numerical models are used to calculate the atmospheric parameters, with observations used to define model cases, tune model parameters, and validate results. This joint program has resulted in a spacecraft capable of accessing, with minimal risk, the four finalist sites chosen for their scientific merit. The capability to operate the landed rover over the latitude range of candidate landing sites, and for all seasons, was verified against an analysis of surface environmental conditions described here. These results, from orbital and model data sets, also drive engineering simulations of the rover's thermal state that are used to plan surface operations.

  7. Comparison of retrograde intrarenal surgery, shockwave lithotripsy, and percutaneous nephrolithotomy for treatment of medium-sized radiolucent renal stones.

    PubMed

    Resorlu, Berkan; Unsal, Ali; Ziypak, Tevfik; Diri, Akif; Atis, Gokhan; Guven, Selcuk; Sancaktutar, Ahmet Ali; Tepeler, Abdulkadir; Bozkurt, Omer Faruk; Oztuna, Derya

    2013-12-01

    To compare the outcomes of shock wave lithotripsy (SWL), percutaneous nephrolithotomy (PNL), and retrograde intrarenal surgery (RIRS) for 10-20 mm radiolucent renal calculi by evaluating stone-free rates and associated complications. A total of 437 patients at 7 institutions who underwent SWL (n = 251), PNL (n = 140), or RIRS (n = 46) were enrolled in our study. Clinical success was defined as stone-free status or asymptomatic insignificant residual fragments <3 mm. The success rates, auxiliary procedures, and complications were compared in each group. Success rates were 66.5, 91.4, and 87% for SWL, PNL, and RIRS (p < 0.001). The need for auxiliary procedures was more common after SWL than PNL and RIRS (21.9 vs 5.7 vs 8.7%, respectively; p < 0.001). The overall complication rates for the SWL, PNL, and RIRS were 7.6, 22.1, and 10.9%, respectively (p < 0.001). Thirteen patients in PNL group received blood transfusions, while none of the patients in RIRS and SWL groups transfused. Hospitalization time per patient was 1.3 ± 0.5 days in the RIRS group, while it was 2.6 ± 0.9 days in the PNL group (p < 0.001). Fluoroscopy and operation time were significantly longer in the PNL group compared to RIRS (145.7 ± 101.7 vs 28.7 ± 18.7 s, and 57.5 ± 22.1 vs 43.1 ± 17 min, respectively). For treatment of moderate-sized radiolucent renal stones, RIRS and PNL provide significantly higher success and lower retreatment rate compared with SWL. Although PNL is effective, its biggest drawback is its invasiveness. Blood loss, radiation exposure, hospital stay, and morbidities of PNL can be significantly reduced with RIRS technique.

  8. Does previous open renal surgery or percutaneous nephrolithotomy affect the outcomes and complications of percutaneous nephrolithotomy.

    PubMed

    Ozgor, Faruk; Kucuktopcu, Onur; Sarılar, Omer; Toptas, Mehmet; Simsek, Abdulmuttalip; Gurbuz, Zafer Gokhan; Akbulut, Mehmet Fatih; Muslumanoglu, Ahmet Yaser; Binbay, Murat

    2015-11-01

    In this study, we aim to evaluate the effectiveness and safety of PNL in patients with a history of open renal surgery or PNL by comparing with primary patients and to compare impact of previous open renal surgery and PNL on the success and complications of subsequent PNL. Charts of patients, who underwent PNL at our institute, were analyzed retrospectively. Patients were divided into three groups according to history of renal stone surgery. Patients without history of renal surgery were enrolled into Group 1. Other patients with previous PNL and previous open surgery were categorized as Group 2 and Group 3. Preoperative characteristic, perioperative data, stone-free status, and complication rates were compared between the groups. Stone-free status was accepted as completing clearance of stone and residual fragment smaller than 4 mm. Eventually, 2070 patients were enrolled into the study. Open renal surgery and PNL had been done in 410 (Group 2) and 131 (Group 3) patients, retrospectively. The mean operation time was longer (71.3 ± 33.5 min) in Group 2 and the mean fluoroscopy time was longer (8.6 ± 5.0) in Group 3 but there was no statistically significant difference between the groups. Highest stone clearance was achieved in primary PNL patients (81.62%) compared to the other groups (77.10% in Group 2 and 75.61% in Group 3). Stone-free rate was not significantly different between Group 2 and Group 3. Fever, pulmonary complications, and blood transfusion requirement were not statically different between groups but angioembolization was significantly higher in Group 2. Percutaneous nephrolithotomy is a safe and effective treatment modality for patients with renal stones regardless history of previous PNL or open renal surgery. However, history of open renal surgery but not PNL significantly reduced PNL success.

  9. Emergency Procedure Training for Reactor Operators at the High Flux Beam Reactor for Brookhaven National Laboratory.

    ERIC Educational Resources Information Center

    Reyer, Ronald

    A project was conducted to analyze, design, develop, implement, and evaluate an instructional unit intended to improve the diagnostic skills of operating personnel in responding to abnormal and emergency conditions at the High Flux Beam Reactor at Brookhaven National Laboratory. Research was conducted on the occurrence of emergencies at similar…

  10. Environmental analysis of the operation of Oak Ridge National Laboratory (X-10 site)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boyle, J.W.; Blumberg, R.; Cotter, S.J.

    1982-11-01

    An environmental analysis of the operation of the Oak Ridge National Laboratory (ORNL) facilities in Bethel Valley and Melton Valley was conducted to present to the public information concerning the extent to which recognizable effects, or potential effects, on the environment may occur. The analysis addresses current operations of the ORNL X-10 site and completed operations that may continue to have residual effects. Solid wastes from ORNL operations at the Y-12 site which are transported to the X-10 site for burial (e.g., Biology Division animal wastes) are included as part of X-10 site operation. Socioeconomic effects are associated primarily withmore » the communities where employees live and with the Knoxville Bureau of Economic Analysis economic area as a whole. Therefore, ORNL employees at both Y-12 and X-10 sites are included in the ORNL socioeconomic impact analysis. An extensive base of environmental data was accumulated for this report. Over 80 reports related to ORNL facilities and/or operations are cited as well as many open-literature citations. Environmental effects of the operation of ORNL result from operational discharges from the onsite facilities; construction and/or modification of facilities, transportation to and from the site of persons, goods and services; socioeconomic impacts to the local, regional, and general population; and accidental discharges if they should occur. Operational discharges to the environnment are constrained by federal, state, and local regulations and by criteria established by the US Department of Energy to minimize adverse impacts. It is the purpose of this document to evaluate the operation of the ORNL insofar as impacts beyond the site boundary may occur or have the potential for occurrence.« less

  11. Integrating standard operating procedures and industry notebook standards to evaluate students in laboratory courses.

    PubMed

    Wallert, Mark A; Provost, Joseph J

    2014-01-01

    To enhance the preparedness of graduates from the Biochemistry and Biotechnology (BCBT) Major at Minnesota State University Moorhead for employment in the bioscience industry we have developed a new Industry certificate program. The BCBT Industry Certificate was developed to address specific skill sets that local, regional, and national industry experts identified as lacking in new B.S. and B.A. biochemistry graduates. The industry certificate addresses concerns related to working in a regulated industry such as Good Laboratory Practices, Good Manufacturing Practices, and working in a Quality System. In this article we specifically describe how we developed a validation course that uses Standard Operating Procedures to describe grading policy and laboratory notebook requirements in an effort to better prepare students to transition into industry careers. © 2013 by The International Union of Biochemistry and Molecular Biology.

  12. Safety in the Chemical Laboratory: Procedures for Laboratory Destruction of Chemicals.

    ERIC Educational Resources Information Center

    McKusick, Blaine C.

    1984-01-01

    Discusses a National Research Council report which summarizes what laboratories need to know about Environmental Protection Agency and Department of Transportation regulations that apply to laboratory waste. The report provides guidelines for establishing and operating waste management systems for laboratories and gives specific advice on waste…

  13. CFD analysis of laboratory scale phase equilibrium cell operation

    NASA Astrophysics Data System (ADS)

    Jama, Mohamed Ali; Nikiforow, Kaj; Qureshi, Muhammad Saad; Alopaeus, Ville

    2017-10-01

    For the modeling of multiphase chemical reactors or separation processes, it is essential to predict accurately chemical equilibrium data, such as vapor-liquid or liquid-liquid equilibria [M. Šoóš et al., Chem. Eng. Process.: Process Intensif. 42(4), 273-284 (2003)]. The instruments used in these experiments are typically designed based on previous experiences, and their operation verified based on known equilibria of standard components. However, mass transfer limitations with different chemical systems may be very different, potentially falsifying the measured equilibrium compositions. In this work, computational fluid dynamics is utilized to design and analyze laboratory scale experimental gas-liquid equilibrium cell for the first time to augment the traditional analysis based on plug flow assumption. Two-phase dilutor cell, used for measuring limiting activity coefficients at infinite dilution, is used as a test case for the analysis. The Lagrangian discrete model is used to track each bubble and to study the residence time distribution of the carrier gas bubbles in the dilutor cell. This analysis is necessary to assess whether the gas leaving the cell is in equilibrium with the liquid, as required in traditional analysis of such apparatus. Mass transfer for six different bio-oil compounds is calculated to determine the approach equilibrium concentration. Also, residence times assuming plug flow and ideal mixing are used as reference cases to evaluate the influence of mixing on the approach to equilibrium in the dilutor. Results show that the model can be used to predict the dilutor operating conditions for which each of the studied gas-liquid systems reaches equilibrium.

  14. CFD analysis of laboratory scale phase equilibrium cell operation.

    PubMed

    Jama, Mohamed Ali; Nikiforow, Kaj; Qureshi, Muhammad Saad; Alopaeus, Ville

    2017-10-01

    For the modeling of multiphase chemical reactors or separation processes, it is essential to predict accurately chemical equilibrium data, such as vapor-liquid or liquid-liquid equilibria [M. Šoóš et al., Chem. Eng. Process Intensif. 42(4), 273-284 (2003)]. The instruments used in these experiments are typically designed based on previous experiences, and their operation verified based on known equilibria of standard components. However, mass transfer limitations with different chemical systems may be very different, potentially falsifying the measured equilibrium compositions. In this work, computational fluid dynamics is utilized to design and analyze laboratory scale experimental gas-liquid equilibrium cell for the first time to augment the traditional analysis based on plug flow assumption. Two-phase dilutor cell, used for measuring limiting activity coefficients at infinite dilution, is used as a test case for the analysis. The Lagrangian discrete model is used to track each bubble and to study the residence time distribution of the carrier gas bubbles in the dilutor cell. This analysis is necessary to assess whether the gas leaving the cell is in equilibrium with the liquid, as required in traditional analysis of such apparatus. Mass transfer for six different bio-oil compounds is calculated to determine the approach equilibrium concentration. Also, residence times assuming plug flow and ideal mixing are used as reference cases to evaluate the influence of mixing on the approach to equilibrium in the dilutor. Results show that the model can be used to predict the dilutor operating conditions for which each of the studied gas-liquid systems reaches equilibrium.

  15. Regulatory issues in accreditation of toxicology laboratories.

    PubMed

    Bissell, Michael G

    2012-09-01

    Clinical toxicology laboratories and forensic toxicology laboratories operate in a highly regulated environment. This article outlines major US legal/regulatory issues and requirements relevant to accreditation of toxicology laboratories (state and local regulations are not covered in any depth). The most fundamental regulatory distinction involves the purposes for which the laboratory operates: clinical versus nonclinical. The applicable regulations and the requirements and options for operations depend most basically on this consideration, with clinical toxicology laboratories being directly subject to federal law including mandated options for accreditation and forensic toxicology laboratories being subject to degrees of voluntary or state government–required accreditation.

  16. Percutaneous nephrolithotomy in children: A preliminary report.

    PubMed

    Elderwy, Ahmad A; Gadelmoula, Mohamed; Elgammal, Mohamed A; Osama, Ehab; Al-Hazmi, Hamdan; Hammouda, H; Osman, Esam; Abdullah, Medhat A; Neel, Khalid Fouda

    2014-07-01

    The recurrence of pediatric nephrolithiasis, the morbidity of repeated open surgical treatment as well as our experience in percutaneous nephrolithotomy (PNL) in adult patients, all derived us to shift to PNL for managing renal stones >1.5 cm in pediatric patients. Our aim of this study is to evaluate the safety and efficacy of PNL in pediatric patients. During the period of the month between May 2011 and April 2013, 38 children (47 renal units) underwent PNL for renal stones 1.5-5 cm in length. Patient demographics, stone characteristics, and clinical outcome were prospectively studied. Data of those who underwent conventional and tubeless PNL were compared. Median follow-up period was 12 months (range: 6-24). The median age at presentation was 8-year (range: 3-12). The operative time ranged from 30 to 120 min (median 90). Overall stone clearance rate was 91.5% after single PNL. The median hospital stay was 3 days. Auxiliary procedures were successful for the remaining 4 patients (nephroscopic clearance in one and shockwave lithotripsy in 3). Tubeless PNL was performed in 17 renal units with a comparable outcome to conventional ones. The perioperative complications were noted in 5/47 (10.6%) of all procedures (Clavien Grade II in 4 and Clavien Grade IIIa in 1) and were managed conservatively. Percutaneous nephrolithotomy for renal stones in pediatric patients is safe and feasible if performed by a well-experienced endourologist. Tubeless PNL is a better choice for children.

  17. Comparison of retrograde intrarenal surgery and mini-percutaneous nephrolithotomy in management of lower-pole renal stones with a diameter of smaller than 15 mm.

    PubMed

    Kirac, Mustafa; Bozkurt, Ömer Faruk; Tunc, Lutfi; Guneri, Cagri; Unsal, Ali; Biri, Hasan

    2013-06-01

    The aim of this study was to compare the outcomes of retrograde intrarenal surgery (RIRS) and miniaturized percutaneous nephrolithotomy (mini-PNL) in management of lower-pole renal stones with a diameter smaller than 15 mm. Between December 2009 and July 2012, the patients with the diagnosis of lower-pole stones were evaluated by ultrasonography, intravenous pyelography and computed tomography. The records of 73 evaluable patients who underwent mini-PNL (n = 37) or RIRS (n = 36) for lower-pole (LP) stones with diameter smaller than 15 mm were reviewed retrospectively. Of the 73 patients, 37 underwent mini-PNL and 36 underwent RIRS. The stone-free rates were 89.1 and 88.8 % for mini-PNL and RIRS groups, respectively. The mean operation time was 53.7 ± 14.5 in the mini-PNL group but 66.4 ± 15.8 in the RIRS group (P = 0.01). The mean fluoroscopy times and hospitalization times were significantly higher in the mini-PNL group. There was no major complication in any patient. RIRS and mini-PNL are safe and effective methods for treatment of LP calculi with a diameter smaller than 15 mm. RIRS is a non-invasive and feasible treatment option, and has also short hospitalization time, low morbidity and complication rate. It may be an alternative of mini-PNL in the treatment LP calculi with smaller than 15 mm.

  18. Pacific Northwest Laboratory annual report for 1987 to the DOE Office of Energy Research: Part 1, Biomedical Sciences

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, J.F.

    1988-02-01

    This report summarizes progress on OHER biomedical and health-effects research conducted at Pacific Northwest Laboratory in FY 1987. The research develops the knowledge and scientific principles necessary to identify, understand, and anticipate the long-term health consequences of energy-related radiation and chemicals. Our continuing emphasis is to decrease the uncertainty of health-effects risk estimates from existing and/or developing energy-related technologies through an increased understanding of how radiation and chemicals cause health effects. The report is arranged to reflect PNL research relative to OHER programmatic structure. The first section, on human health effects, concerns statistical and epidemiological studies for assessing health risks.more » The next section, which contains reports of health-effects research in biological systems, includes research with radiation and chemicals. The last section is related to medical applications of nuclear technology.« less

  19. Lawrence Livermore National Laboratory Experimental Test Site (Site 300) Potable Water System Operations Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ocampo, Ruben P.; Bellah, Wendy

    The existing Lawrence Livermore National Laboratory (LLNL) Site 300 drinking water system operation schematic is shown in Figures 1 and 2 below. The sources of water are from two Site 300 wells (Well #18 and Well #20) and San Francisco Public Utilities Commission (SFPUC) Hetch-Hetchy water through the Thomas shaft pumping station. Currently, Well #20 with 300 gallons per minute (gpm) pump capacity is the primary source of well water used during the months of September through July, while Well #18 with 225 gpm pump capacity is the source of well water for the month of August. The well watermore » is chlorinated using sodium hypochlorite to provide required residual chlorine throughout Site 300. Well water chlorination is covered in the Lawrence Livermore National Laboratory Experimental Test Site (Site 300) Chlorination Plan (“the Chlorination Plan”; LLNL-TR-642903; current version dated August 2013). The third source of water is the SFPUC Hetch-Hetchy Water System through the Thomas shaft facility with a 150 gpm pump capacity. At the Thomas shaft station the pumped water is treated through SFPUC-owned and operated ultraviolet (UV) reactor disinfection units on its way to Site 300. The Thomas Shaft Hetch- Hetchy water line is connected to the Site 300 water system through the line common to Well pumps #18 and #20 at valve box #1.« less

  20. Percutaneous Nephrolithotomy in Patients With BMI >50: Single Surgeon Outcomes and Feasibility.

    PubMed

    Streeper, Necole M; Radtke, Andrew C; Penniston, Kristina L; McDermott, John C; Nakada, Stephen Y

    2016-01-01

    To evaluate the use of percutaneous nephrolithotomy (PNL) and technical approach in the super obese population (body mass index [BMI] ≥ 50). We performed a retrospective review of 31 consecutive PNL cases with a BMI > 50 from a single surgeon (SYN) from 1995 to 2013. Procedures were performed in the prone position, and upper pole access was used. Operative time, length of hospital stay, stone burden, complication rates, and stone-free rates were measured. Of the 31 patients who underwent PNL (age 51.2 ± 12; 71% female), the mean BMI was 59.1 ± 6 kg/m(2) (range 50.4-71.7 kg/m(2)). Mean stone burden was 3.8 cm ± 2. The majority of patients (90.3%) had an upper pole puncture site for access with an operative time of 122.1 ± 75 minutes. The technique was similar to non-obese patients; however, there was a need for extra-long instrumentation. The overall stone-free rate was 71%, with utilization of a second-look PNL in 11 cases. The complication rate, Clavien grade 3 or higher, was 9.7% (3 of 31). PNL is technically feasible, safe, and effective in patients with a BMI ≥ 50. The complication rate, length of hospital stay, and stone-free rate with use of second-look PNL in super obese patients are comparable to severely obese patients. Intervention should not be automatically ruled out or delayed based on the patient's BMI alone. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Experimental animal studies of radon and cigarette smoke

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cross, F.T.; Dagle, G.E.; Gies, R.A.

    Cigarette-smoking is a dominant cause of lung cancer and confounds risk assessment of exposure to radon decay products. Evidence in humans on the interaction between cigarette-smoking and exposure to radon decay products, although limited, indicates a possible synergy. Experimental animal data, in addition to showing synergy, also show a decrease or no change in risk with added cigarette-smoke exposures. This article reviews previous animal data developed at Compagnie Generale des Matieres Nucleaires and Pacific Northwest Laboratory (PNL) on mixed exposures to radon and cigarette smoke, and highlights new initiation-promotion-initiation (IPI) studies at PNL that were designed within the framework ofmore » a two-mutation carcinogenesis model. Also presented are the PNL exposure system, experimental protocols, dosimetry, and biological data observed to date in IPI animals.« less

  2. Recommendations for the treatment of aging in standard technical specifications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Orton, R.D.; Allen, R.P.

    1995-09-01

    As part of the US Nuclear Regulatory Commission`s Nuclear Plant Aging Research Program, Pacific Northwest Laboratory (PNL) evaluated the standard technical specifications for nuclear power plants to determine whether the current surveillance requirements (SRs) were effective in detecting age-related degradation. Nuclear Plant Aging Research findings for selected systems and components were reviewed to identify the stressors and operative aging mechanisms and to evaluate the methods available to detect, differentiate, and trend the resulting aging degradation. Current surveillance and testing requirements for these systems and components were reviewed for their effectiveness in detecting degraded conditions and for potential contributions to prematuremore » degradation. When the current surveillance and testing requirements appeared ineffective in detecting aging degradation or potentially could contribute to premature degradation, a possible deficiency in the SRs was identified that could result in undetected degradation. Based on this evaluation, PNL developed recommendations for inspection, surveillance, trending, and condition monitoring methods to be incorporated in the SRs to better detect age- related degradation of these selected systems and components.« less

  3. Surgical management of urinary stones with abnormal kidney anatomy.

    PubMed

    Ergin, Giray; Kirac, Mustafa; Unsal, Ali; Kopru, Burak; Yordam, Mustafa; Biri, Hasan

    2017-04-01

    In spite of the fact that urologic surgical techniques used by urologists are becoming more and more minimally invasive and easier because of developing technologies, surgical approaches for the urinary stones in kidneys with abnormal anatomy are still confusing. The objective of this article is to determine the treatment options in these kidneys. For this purpose, between 2005 and 2015, we retrospectively evaluated patients operated for urolithiasis with various congenital renal anomalies in five referral urology clinics in our country. Of the 178 patients (110 male, 60 female), 96 had horseshoe kidneys, 42 had pelvic ectopic kidneys (PEKs), and 40 had isolated rotation anomalies (IRAs) of the kidney. We evaluated the patients for stone-free rate (SFR), mean operation time, mean hospitalization time, and complication rate. In horseshoe kidney, SFRs for retrograde intrarenal surgery (RIRS) and percutaneous nephrolithotomy (PNL) groups were 72.2% and 90%, respectively. In PEKs, these rates were 83.6% and 100% for RIRS and laparoscopic pyelolithotomy, respectively. SFRs in kidneys with IRA were 75% for RIRS and 83.3% for PNL. The mean operation time for RIRS and PNL groups in horseshoe kidney was 40.5±11.2 minutes and 74.5±19.3 minutes, respectively. In PEKs, these times were 52.1±19.3 minutes and 53.1±24.3 minutes for RIRS and laparoscopic pyelolithotomy, respectively. Mean operation time in kidneys with IRA was 48.7±14.4 minutes for RIRS and 53.2±11.3 minutes for PNL. Mean hospitalization times for RIRS and PNL groups in horseshoe kidneys were 1.4±0.7 days and 2.2±1.4 days, respectively. In PEKs, these times were 2.7±1.8 days and 1.9±0.4 days for RIRS and laparoscopic pyelolithotomy, respectively. Mean operation time in kidneys with IRA was 1.5±0.9 days for RIRS and 1.8±0.6 days for PNL. The results of our study showed that RIRS could be used in all of types of abnormal kidneys with small- and medium-sized renal calculi safely and satisfactorily

  4. Comparison of retrograde intrarenal surgery versus a single-session percutaneous nephrolithotomy for lower-pole stones with a diameter of 15 to 30 mm: A propensity score-matching study.

    PubMed

    Jung, Gyoo Hwan; Jung, Jae Hyun; Ahn, Tae Sik; Lee, Joong Sub; Cho, Sung Yong; Jeong, Chang Wook; Lee, Seung Bae; Kim, Hyeon Hoe; Oh, Seung-June

    2015-07-01

    To investigate surgical outcomes between retrograde intrarenal surgery (RIRS) and percutaneous nephrolithotomy (PNL) groups for a main stone sized 15 to 30 mm and located in the lower-pole calyx. Patients who underwent PNL or RIRS for a main stone sized 15 to 30 mm and located in the lower-pole calyx were retrospectively reviewed. Each patient in the RIRS group was matched to one in the PNL group on the basis of calculated propensity scores by use of age, sex, body mass index, previous treatment history, stone site, maximum stone size, and stone volume. We compared perioperative outcomes between the unmatched and matched groups. Patients underwent PNL (n=87, 66.4%) or RIRS (n=44, 33.6%). After matching, 44 patients in each group were included. Mean patient age was 54.4 ± 13.7 years. Perioperative hemoglobin drop was significantly higher and the hospital stay was longer in the PNL group than in the RIRS group. The operative time was significantly longer in the RIRS group than in the PNL group. Stone-free rates were higher and complications rates were lower in the RIRS group than in the PNL group without statistical significance. The presence of a stone located in the lower-anterior minor calyx was a predictor of stone-free status. RIRS and single-session PNL for patients with a main stone of 15 to 30 mm located in the lower-pole calyx showed comparable surgical results. However, RIRS can be performed more safely than PNL with less bleeding. Stones in the lower-anterior minor calyx should be carefully removed during these procedures.

  5. Comparison of retrograde intrarenal surgery versus a single-session percutaneous nephrolithotomy for lower-pole stones with a diameter of 15 to 30 mm: A propensity score-matching study

    PubMed Central

    Jung, Gyoo Hwan; Jung, Jae Hyun; Ahn, Tae Sik; Lee, Joong Sub; Cho, Sung Yong; Jeong, Chang Wook; Lee, Seung Bae; Kim, Hyeon Hoe

    2015-01-01

    Purpose To investigate surgical outcomes between retrograde intrarenal surgery (RIRS) and percutaneous nephrolithotomy (PNL) groups for a main stone sized 15 to 30 mm and located in the lower-pole calyx. Materials and Methods Patients who underwent PNL or RIRS for a main stone sized 15 to 30 mm and located in the lower-pole calyx were retrospectively reviewed. Each patient in the RIRS group was matched to one in the PNL group on the basis of calculated propensity scores by use of age, sex, body mass index, previous treatment history, stone site, maximum stone size, and stone volume. We compared perioperative outcomes between the unmatched and matched groups. Results Patients underwent PNL (n=87, 66.4%) or RIRS (n=44, 33.6%). After matching, 44 patients in each group were included. Mean patient age was 54.4±13.7 years. Perioperative hemoglobin drop was significantly higher and the hospital stay was longer in the PNL group than in the RIRS group. The operative time was significantly longer in the RIRS group than in the PNL group. Stone-free rates were higher and complications rates were lower in the RIRS group than in the PNL group without statistical significance. The presence of a stone located in the lower-anterior minor calyx was a predictor of stone-free status. Conclusions RIRS and single-session PNL for patients with a main stone of 15 to 30 mm located in the lower-pole calyx showed comparable surgical results. However, RIRS can be performed more safely than PNL with less bleeding. Stones in the lower-anterior minor calyx should be carefully removed during these procedures. PMID:26175872

  6. The Point-of-Care Laboratory in Clinical Microbiology

    PubMed Central

    Michel-Lepage, Audrey; Boyer, Sylvie; Raoult, Didier

    2016-01-01

    SUMMARY Point-of-care (POC) laboratories that deliver rapid diagnoses of infectious diseases were invented to balance the centralization of core laboratories. POC laboratories operate 24 h a day and 7 days a week to provide diagnoses within 2 h, largely based on immunochromatography and real-time PCR tests. In our experience, these tests are conveniently combined into syndrome-based kits that facilitate sampling, including self-sampling and test operations, as POC laboratories can be operated by trained operators who are not necessarily biologists. POC laboratories are a way of easily providing clinical microbiology testing for populations distant from laboratories in developing and developed countries and on ships. Modern Internet connections enable support from core laboratories. The cost-effectiveness of POC laboratories has been established for the rapid diagnosis of tuberculosis and sexually transmitted infections in both developed and developing countries. PMID:27029593

  7. Value added data archiving

    NASA Technical Reports Server (NTRS)

    Berard, Peter R.

    1993-01-01

    Researchers in the Molecular Sciences Research Center (MSRC) of Pacific Northwest Laboratory (PNL) currently generate massive amounts of scientific data. The amount of data that will need to be managed by the turn of the century is expected to increase significantly. Automated tools that support the management, maintenance, and sharing of this data are minimal. Researchers typically manage their own data by physically moving datasets to and from long term storage devices and recording a dataset's historical information in a laboratory notebook. Even though it is not the most efficient use of resources, researchers have tolerated the process. The solution to this problem will evolve over the next three years in three phases. PNL plans to add sophistication to existing multilevel file system (MLFS) software by integrating it with an object database management system (ODBMS). The first phase in the evolution is currently underway. A prototype system of limited scale is being used to gather information that will feed into the next two phases. This paper describes the prototype system, identifies the successes and problems/complications experienced to date, and outlines PNL's long term goals and objectives in providing a permanent solution.

  8. Development and operation of a quality assurance system for deviations from standard operating procedures in a clinical cell therapy laboratory.

    PubMed

    McKenna, D; Kadidlo, D; Sumstad, D; McCullough, J

    2003-01-01

    Errors and accidents, or deviations from standard operating procedures, other policy, or regulations must be documented and reviewed, with corrective actions taken to assure quality performance in a cellular therapy laboratory. Though expectations and guidance for deviation management exist, a description of the framework for the development of such a program is lacking in the literature. Here we describe our deviation management program, which uses a Microsoft Access database and Microsoft Excel to analyze deviations and notable events, facilitating quality assurance (QA) functions and ongoing process improvement. Data is stored in a Microsoft Access database with an assignment to one of six deviation type categories. Deviation events are evaluated for potential impact on patient and product, and impact scores for each are determined using a 0- 4 grading scale. An immediate investigation occurs, and corrective actions are taken to prevent future similar events from taking place. Additionally, deviation data is collectively analyzed on a quarterly basis using Microsoft Excel, to identify recurring events or developing trends. Between January 1, 2001 and December 31, 2001 over 2500 products were processed at our laboratory. During this time period, 335 deviations and notable events occurred, affecting 385 products and/or patients. Deviations within the 'technical error' category were most common (37%). Thirteen percent of deviations had a patient and/or a product impact score > or = 2, a score indicating, at a minimum, potentially affected patient outcome or moderate effect upon product quality. Real-time analysis and quarterly review of deviations using our deviation management program allows for identification and correction of deviations. Monitoring of deviation trends allows for process improvement and overall successful functioning of the QA program in the cell therapy laboratory. Our deviation management program could serve as a model for other laboratories in

  9. Percutaneous nephrolithotomy in children: A preliminary report

    PubMed Central

    Elderwy, Ahmad A.; Gadelmoula, Mohamed; Elgammal, Mohamed A.; Osama, Ehab; Al-Hazmi, Hamdan; Hammouda, H.; Osman, Esam; Abdullah, Medhat A.; Neel, Khalid Fouda

    2014-01-01

    Objectives: The recurrence of pediatric nephrolithiasis, the morbidity of repeated open surgical treatment as well as our experience in percutaneous nephrolithotomy (PNL) in adult patients, all derived us to shift to PNL for managing renal stones >1.5 cm in pediatric patients. Our aim of this study is to evaluate the safety and efficacy of PNL in pediatric patients. Materials and Methods: During the period of the month between May 2011 and April 2013, 38 children (47 renal units) underwent PNL for renal stones 1.5-5 cm in length. Patient demographics, stone characteristics, and clinical outcome were prospectively studied. Data of those who underwent conventional and tubeless PNL were compared. Median follow-up period was 12 months (range: 6-24). Results: The median age at presentation was 8-year (range: 3-12). The operative time ranged from 30 to 120 min (median 90). Overall stone clearance rate was 91.5% after single PNL. The median hospital stay was 3 days. Auxiliary procedures were successful for the remaining 4 patients (nephroscopic clearance in one and shockwave lithotripsy in 3). Tubeless PNL was performed in 17 renal units with a comparable outcome to conventional ones. The perioperative complications were noted in 5/47 (10.6%) of all procedures (Clavien Grade II in 4 and Clavien Grade IIIa in 1) and were managed conservatively. Conclusions: Percutaneous nephrolithotomy for renal stones in pediatric patients is safe and feasible if performed by a well-experienced endourologist. Tubeless PNL is a better choice for children. PMID:25125889

  10. SWEIS Yearbook-2012 Comparison of 2012 Data to Projections of the 2008 Site-Wide Environmental Impact Statement for Continued Operation of Los Alamos National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mahowald, Hallie B.; Wright, Marjorie Alys

    2014-01-16

    Los Alamos National Laboratory (LANL or the Laboratory) operations data for Calendar Year (CY) 2012 mostly fell within the 2008 Site-Wide Environmental Impact Statement (SWEIS) projections. Operation levels for one LANL facility exceeded the 2008 SWEIS capability projections—Radiochemistry Facility; however, none of the capability increases caused exceedances in radioactive air emissions, waste generation, or National Pollutant Discharge Elimination System (NPDES) discharge. Several facilities exceeded the2008 SWEIS levels for waste generation quantities; however, all were one-time, non-routine events that do not reflect the day-to-day operations of the Laboratory. In addition, total site-wide waste generation quantities were below SWEIS projections for allmore » waste types, reflecting the overall levels of operations at both the Key and Non-Key Facilities. Although gas and electricity consumption have remained within the 2008 SWEIS limits for utilities, water consumption exceeded the 2008 SWEIS projections by 27 million gallons in CY 2012.« less

  11. Impact of Nuclear Laboratory Personnel Credentials & Continuing Education on Nuclear Cardiology Laboratory Quality Operations.

    PubMed

    Malhotra, Saurabh; Sobieraj, Diana M; Mann, April; Parker, Matthew W

    2017-12-22

    Background/Objectives: The specific credentials and continuing education (CME/CE) of nuclear cardiology laboratory medical and technical staff are important factors in the delivery of quality imaging services that have not been systematically evaluated. Methods: Nuclear cardiology accreditation application data from the Intersocietal Accreditation Commission (IAC) was used to characterize facilities performing myocardial perfusion imaging by setting, size, previous accreditation and credentials of the medical and technical staff. Credentials and CME/CE were compared against initial accreditation decisions (grant or delay) using multivariable logistic regression. Results: Complete data were available for 1913 nuclear cardiology laboratories from 2011-2014. Laboratories with initial positive accreditation decisions had a greater prevalence of Certification Board in Nuclear Cardiology (CBNC) certified medical directors and specialty credentialed technical directors. Certification and credentials of the medical and technical directors, respectively, staff CME/CE compliance, and assistance of a consultant with the application were positively associated with accreditation decisions. Conclusion: Nuclear cardiology laboratories directed by CBNC-certified physicians and NCT- or PET-credentialed technologists were less likely to receive delay decisions for MPI. CME/CE compliance of both the medical and technical directors was associated with accreditation decision. Medical and technical directors' years of experience were not associated with accreditation decision. Copyright © 2017 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  12. Electromagnetic Measurements Conducted by the Central Radio Propagation Laboratory During Operation Upshot-Knothole (Redacted)

    DTIC Science & Technology

    1954-03-31

    b . ABSTRACT c. THIS PAGE 19b. TELEPHONE NUMBER (include area code) Standard Form 298 (Re . 8-98) v Prescribed by ANSI Std. Z39.18 31...March 1954 Final report Electromagnetic Measurements Conducted by the Central Radio Propagation Laboratory During Operation Upshot-Knothole B /216/E...Vubington 25, D. C. COD fw 5 U.S.C. § 552 ( b )( 6) O££ice (or AtOIIIie Fnergy, DCS/0 r r T l A . O!tp1rtment o£ the 1\\ir force \\ ·-’ . If

  13. Definition of experiments and instruments for a communication/navigation research laboratory. Volume 3: Laboratory descriptions

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The following study objectives are covered: (1) identification of major laboratory equipment; (2) systems and operations analysis in support of the laboratory design; and (3) conceptual design of the comm/nav research laboratory.

  14. CIEMAT EXTERNAL DOSIMETRY SERVICE: ISO/IEC 17025 ACCREDITATION AND 3 Y OF OPERATIONAL EXPERIENCE AS AN ACCREDITED LABORATORY.

    PubMed

    Romero, A M; Rodríguez, R; López, J L; Martín, R; Benavente, J F

    2016-09-01

    In 2008, the CIEMAT Radiation Dosimetry Service decided to implement a quality management system, in accordance with established requirements, in order to achieve ISO/IEC 17025 accreditation. Although the Service comprises the approved individual monitoring services of both external and internal radiation, this paper is specific to the actions taken by the External Dosimetry Service, including personal and environmental dosimetry laboratories, to gain accreditation and the reflections of 3 y of operational experience as an accredited laboratory. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Analysis of Changes in the Glomerular Filtration Rate as Measured by the Cockroft-Gault Formula in the Early Period after Percutaneous Nephrolithotomy

    PubMed Central

    Seckiner, Ilker; Erturhan, Sakip M.; Mizrak, Sedat; Erbagci, Ahmet

    2012-01-01

    Purpose We aimed to analyze the changes in kidney function during the postoperative early period caused by the application of percutaneous nephrolithotomy (PNL), which is commonly used in kidney stone surgery. Materials and Methods PNL was performed in 80 patients (48 men, 32 women) with kidney stones. The mean age of the patients was 43.71 years (range, 18 to 71 years). Preoperative and postoperative values for stone size, glomerular filtration rate (GFR), serum creatinine, urea, electrolytes (Na, K, Cl), and Hb were compared in 80 patients in whom PNL surgery was performed. The formula of Cockroft-Gault was used to calculate the GFR during the early postoperative period (72 to 96 hours). Results Statistically significant decreases after PNL were observed in average stone size (preoperative, 627.75±375.10 mm2; postoperative, 81.70±16.15 mm2), serum urea (preoperative, 38.40±17.26 mg/dl; postoperative, 33.28±16.98 mg/dl), and creatinine (preoperative, 1.03±0.53 mg/dl; postoperative, 0.97±0.55 mg/dl) and an increase was observed in GFR (preoperative, 104.30±37.30 ml/min; postoperative, 112.38±40.1 ml/min). No changes were detected in the serum electrolyte values (Na, K, Cl). Multiple access, operation time, and type of lithotripter did not have any significant effects on the change in the GFR. Conclusions In light of our results, PNL for kidney stone operations appears to be a reliable and efficient method that provides recovery of kidney functions in the early post-operative period by increasing the GFR and with high stone-free rates. PMID:22950000

  16. Comparison of supine and prone positions for percutaneous nephrolithotomy in treatment of staghorn stones.

    PubMed

    Gökce, Mehmet İlker; Ibiş, Arif; Sancı, Adem; Akıncı, Aykut; Bağcı, Uygar; Ağaoğlu, Eylül Asya; Süer, Evren; Gülpınar, Ömer

    2017-12-01

    Percutaneous nephrolithotomy (PNL) is the primary treatment modality for management of staghorn stones. PNL in supine position has important advantages over prone positon. However, studies comparing prone and supine positions for PNL in staghorn stone patients have conflicting results, and the aim of the current study was to compare prone and supine positions for PNL in staghorn stone cases. Data of patients underwent PNL for staghorn stones in supine or prone position by a single urologist were collected prospectively. The supine and prone position groups were compared for stone free rate (SFR) and complication rates. All patients were evaluated with NCCT for evaluation of SFR. Chi-square test was used to compare categorical variables and Student t test was applied for continuous variables of the treatment groups. The groups were similar for demographic and stone-related characteristics. Multi-caliceal and intercostal access was more common in prone position. Operation duration was significantly shorter and hemoglobin drop was significantly less in supine group. SFR was 64.1 and 60.4% in the supine and prone groups, respectively (p = 0.72). Complication rates were similar in the two groups but Clavien III complications were observed in two patients in the prone group. PNL in supine position is an effective treatment for management of staghorn stones. The need for multi-caliceal and intercostal puncture is less when combined with retrograde intrarenal surgery. PNL in supine position should be considered as primary treatment option in staghorn stone cases.

  17. Comprehensive evaluation of contemporary assisted reproduction technology laboratory operations to determine staffing levels that promote patient safety and quality care.

    PubMed

    Alikani, Mina; Go, Kathryn J; McCaffrey, Caroline; McCulloh, David H

    2014-11-01

    To consider how staffing requirements have changed with evolving and increasingly more complex assisted reproduction technology (ART) laboratory practice. Analysis by four laboratory directors from three different ART programs of the level of complexity and time requirements for contemporary ART laboratory activities to determine adequate staffing levels. University-based and private ART programs. None. None. Human resource requirements for ART procedures. Both complexity and time required for completion of a contemporary ART cycle have increased significantly compared with the same requirements for the "traditional cycle" of the past. The latter required roughly 9 personnel hours, but a contemporary cycle can require up to 20 hours for completion. Consistent with this increase, a quantitative analysis shows that the number of embryologists required for safe and efficient operation of the ART laboratory has also increased. This number depends on not only the volume but also the types of procedures performed: the higher the number of complex procedures, the more personnel required. An interactive Personnel Calculator is introduced that can help determine staffing needs. The increased complexity of the contemporary ART laboratory requires a new look at the allocation of human resources. Our work provides laboratory directors with a practical, individualized tool to determine their staffing requirements with a view to increasing the safety and efficiency of operations. The work could serve as the basis for revision of the 2008 American Society for Reproductive Medicine (ASRM) staffing guidelines. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  18. Mice examined in Animal Laboratory of Lunar Receiving Laboratory

    NASA Technical Reports Server (NTRS)

    1969-01-01

    Landrum Young (seated), Brown and Root-Northrup, and Russell Stullken, Manned Spacecraft Center, examine mice in the Animal laboratory of the Lunar Receiving Laboratory which have been inoculated with lunar sample material. wish for peace for all mankind. astronauts will be released from quarantine on August 11, 1969. Donald K. Slayton (right), MSC Director of Flight Crew Operations; and Lloyd Reeder, training coordinator.

  19. Development of the Design Laboratory.

    ERIC Educational Resources Information Center

    Silla, Harry

    1986-01-01

    Describes the design laboratory at the Stevens Institute of Technology (SIT). Considers course objectives, design projects, project structure, mechanical design, project management, and laboratory operation. This laboratory complements SIT's course in process design, giving students a complete design experience. (JN)

  20. Clinical efficacy, safety, and costs of percutaneous occlusive balloon catheter-assisted ureteroscopic lithotripsy for large impacted proximal ureteral calculi: a prospective, randomized study.

    PubMed

    Qi, Shiyong; Li, Yanni; Liu, Xu; Zhang, Changwen; Zhang, Hongtuan; Zhang, Zhihong; Xu, Yong

    2014-09-01

    To evaluate the clinical efficacy, safety, and costs of percutaneous occlusive balloon catheter-assisted ureteroscopic lithotripsy (POBC-URSL) for large impacted proximal ureteral calculi. 156 patients with impacted proximal ureteral stones ≥1.5 cm in size were randomized to ureteroscopic lithotripsy (URSL), POBC-URSL, and percutaneous nephrolithotomy (PNL) group between May 2010 and May 2013. For URSL, the calculi were disintegrated with the assistance of anti-retropulsion devices. POBC-URSL was performed with the assistance of an 8F percutaneous occlusive balloon catheter. PNL was finished with the combination of an ultrasonic and a pneumatic lithotripter. A flexible ureteroscope and a 200 μm laser fiber were used to achieve stone-free status to a large extent for each group. Variables studied were mean operative time, auxiliary procedure, postoperative hospital stay, operation-related complications, stone clearance rate, and treatment costs. The mean lithotripsy time for POBC-URSL was shorter than URSL, but longer than PNL (42.6±8.9 minutes vs 66.7±15.3 minutes vs 28.1±6.3 minutes, p=0.014). The auxiliary procedure rate and postoperative fever rate for POBC-URSL were significantly lower than URSL and comparable to PNL (p<0.01, p=0.034). POBC-URSL was superior to URSL with regard to the stone clearance rate at 3 days postoperatively, and as good as PNL (98.1% vs 75.0% vs 96.2%, p<0.01). The postoperative hospital stay and hematuria rate were lower in POBC-URSL group than PNL group and similar to URSL group (p=0.016, p<0.01). The treatment costs were lowest in POBC-URSL group ($1205.0±$113.9 vs $1731.7±$208.1 vs $2446.4±$166.4, p=0.004). For large impacted proximal ureteral calculi, POBC-URSL was associated with a higher stone clearance rate, fewer complications and costs. POBC-URSL combined the advantages of URSL and PNL.

  1. Herbicide sorption to fine particulate matter suspended downwind of agricultural operations: field and laboratory investigations.

    PubMed

    Clymo, Amelia S; Shin, Jin Young; Holmen, Britt A

    2005-01-15

    Tillage-induced erosion of herbicides bound to airborne soil particles has not been quantified as a mechanism for offsite herbicide transport. This study quantifies the release of two preemergent herbicides, metolachlor and pendimethalin, to the atmosphere as gas- and particle-phase species during soil incorporation operations. Fine particulate matter (PM2.5) and gas-phase samples were collected at three sampling heights during herbicide disking into the soil in Davis, CA, in May 2000 and May 2001 using filter/PUF sampling. Quartz fiber filters (QFFs) were used in May 2000, and Teflon membrane filters (TMFs) were used in May 2001. The field data were combined with laboratory filter/PUF partitioning experiments to account for adsorption to the filter surfaces and quantify the mass of PM2.5-bound herbicides in the field samples. Laboratory results indicate a significant adsorption of metolachlor, but not pendimethalin, to the quartz filter surfaces. Metolachlor partitioning to PM2.5 collected on TMF filters resulted in corrected PM2.5 field partition coefficient values, Kp,corr = Cp/Cg, of approximately 10(-3.5) m3/microg, indicating its preference for the gas phase. Pendimethalin exhibited more semivolatile behavior,with Kp,corr values that ranged from 10(-3) to 10(-1) m3/ microg and increased with sampling height and distance downwind of the operation. An increase in pendimethalin enrichment at a height of 5 m suggests winnowing of finer, more sorptive soil components with corresponding higher transport potential. Pendimethalin was enriched in the PM2.5 samples by up to a factor of 250 compared to the field soil, indicating thatfurther research on the processes controlling the generation of PM-bound herbicides during agricultural operations is warranted to enable prediction of off-site mass fluxes by this mechanism.

  2. Laboratory Ventilation and Safety.

    ERIC Educational Resources Information Center

    Steere, Norman V.

    1965-01-01

    In order to meet the needs of both safety and economy, laboratory ventilation systems must effectively remove air-borne toxic and flammable materials and at the same time exhaust a minimum volume of air. Laboratory hoods are the most commonly used means of removing gases, dusts, mists, vapors, and fumed from laboratory operations. To be effective,…

  3. Pacific Northwest Laboratory annual report for 1990 to the DOE Office of Energy Research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Toburen, L.H.; Stults, B.R.; Mahaffey, J.A.

    Part four of the PNL Annual Report for 1990 includes research in physical sciences. Individual reports are processed separately for the data bases in the following areas: Dosimetry Research; Measurement Science; Radiological and Chemical Physics; Radiation Dosimetry; Radiation Biophysics; and Modelling Cellular Response to Genetic Damage. (FL)

  4. Smart garments for emergency operators: results of laboratory and field tests.

    PubMed

    Curone, Davide; Dudnik, Gabriela; Loriga, Giannicola; Magenes, Giovanni; Secco, Emanuele Lindo; Tognetti, Alessandro; Bonfiglio, Annalisa

    2008-01-01

    The first generation of ProeTEX prototypes has been completed at the end of August 2007. In the following period two main activities have involved the project partners. On one hand new technologies (in terms of sensors and devices) to be integrated in the next releases of prototypes have been developed; on the other hand intensive test sessions on the first prototype (both in laboratory conditions and simulating real operative scenarios) have been carried out. This paper is mainly focused on this second facet. Great efforts have been dedicated to the trials for different reasons: firstly to investigate the appropriateness and efficiency of the system in normal and harsh conditions; secondly to obtain useful indications regarding usability and efficacy by the end-users involved in the project. The results of the trials have been used to define the specifications of the second generation of prototypes, that will be released within the end of 2008.

  5. A monitor for the laboratory evaluation of control integrity in digital control systems operating in harsh electromagnetic environments

    NASA Technical Reports Server (NTRS)

    Belcastro, Celeste M.; Fischl, Robert; Kam, Moshe

    1992-01-01

    This paper presents a strategy for dynamically monitoring digital controllers in the laboratory for susceptibility to electromagnetic disturbances that compromise control integrity. The integrity of digital control systems operating in harsh electromagnetic environments can be compromised by upsets caused by induced transient electrical signals. Digital system upset is a functional error mode that involves no component damage, can occur simultaneously in all channels of a redundant control computer, and is software dependent. The motivation for this work is the need to develop tools and techniques that can be used in the laboratory to validate and/or certify critical aircraft controllers operating in electromagnetically adverse environments that result from lightning, high-intensity radiated fields (HIRF), and nuclear electromagnetic pulses (NEMP). The detection strategy presented in this paper provides dynamic monitoring of a given control computer for degraded functional integrity resulting from redundancy management errors, control calculation errors, and control correctness/effectiveness errors. In particular, this paper discusses the use of Kalman filtering, data fusion, and statistical decision theory in monitoring a given digital controller for control calculation errors.

  6. Operational evaluation of rapid diagnostic testing for Ebola Virus Disease in Guinean laboratories

    PubMed Central

    Aho, Josephine; Franklin, Kristyn; Likofata, Jacques; Kamgang, Jean Baptiste; Keita, Sakoba; Koivogui, Lamine; Magassouba, N’Faly; Martel, Lise D.; Dahourou, Anicet George

    2017-01-01

    Background Rapid Diagnostic Tests (RDTs) for Ebola Virus Disease (EVD) at the point of care have the potential to increase access and acceptability of EVD testing and the speed of patient isolation and secure burials for suspect cases. A pilot program for EVD RDTs in high risk areas of Guinea was introduced in October 2015. This paper presents concordance data between EVD RDTs and PCR testing in the field as well as an assessment of the acceptability, feasibility, and quality assurance of the RDT program. Methods and findings Concordance data were compiled from laboratory surveillance databases. The operational measures of the laboratory-based EVD RDT program were evaluated at all 34 sentinel sites in Guinea through: (1) a technical questionnaire filled by the lab technicians who performed the RDTs, (2) a checklist filled by the evaluator during the site visits, and (3) direct observation of the lab technicians performing the quality control test. Acceptability of the EVD RDT was good for technicians, patients, and families although many technicians (69.8%) expressed concern for their safety while performing the test. The feasibility of the program was good based on average technician knowledge scores (6.6 out of 8) but basic infrastructure, equipment, and supplies were lacking. There was much room for improvement in quality assurance of the program. Conclusions The implementation of new diagnostics in weak laboratory systems requires general training in quality assurance, biosafety and communication with patients in addition to specific training for the new test. Corresponding capacity building in terms of basic equipment and a long-term commitment to transfer supervision and quality improvement to national public health staff are necessary for successful implementation. PMID:29190713

  7. Operational evaluation of rapid diagnostic testing for Ebola Virus Disease in Guinean laboratories.

    PubMed

    VanSteelandt, Amanda; Aho, Josephine; Franklin, Kristyn; Likofata, Jacques; Kamgang, Jean Baptiste; Keita, Sakoba; Koivogui, Lamine; Magassouba, N'Faly; Martel, Lise D; Dahourou, Anicet George

    2017-01-01

    Rapid Diagnostic Tests (RDTs) for Ebola Virus Disease (EVD) at the point of care have the potential to increase access and acceptability of EVD testing and the speed of patient isolation and secure burials for suspect cases. A pilot program for EVD RDTs in high risk areas of Guinea was introduced in October 2015. This paper presents concordance data between EVD RDTs and PCR testing in the field as well as an assessment of the acceptability, feasibility, and quality assurance of the RDT program. Concordance data were compiled from laboratory surveillance databases. The operational measures of the laboratory-based EVD RDT program were evaluated at all 34 sentinel sites in Guinea through: (1) a technical questionnaire filled by the lab technicians who performed the RDTs, (2) a checklist filled by the evaluator during the site visits, and (3) direct observation of the lab technicians performing the quality control test. Acceptability of the EVD RDT was good for technicians, patients, and families although many technicians (69.8%) expressed concern for their safety while performing the test. The feasibility of the program was good based on average technician knowledge scores (6.6 out of 8) but basic infrastructure, equipment, and supplies were lacking. There was much room for improvement in quality assurance of the program. The implementation of new diagnostics in weak laboratory systems requires general training in quality assurance, biosafety and communication with patients in addition to specific training for the new test. Corresponding capacity building in terms of basic equipment and a long-term commitment to transfer supervision and quality improvement to national public health staff are necessary for successful implementation.

  8. Comparison of High-Speed Operating Characteristics of Size 215 Cylindrical-Roller Bearings as Determined in Turbojet Engine and in Laboratory Test Rig

    NASA Technical Reports Server (NTRS)

    Macks, E Fred; Nemeth, Zolton N

    1952-01-01

    A comparison of the operating characteristics of 75-millimeter-bore (size 215) cylindrical-roller one-piece inner-race-riding cage-type bearings was made by means of a laboratory test rig and a turbojet engine. Cooling correlation parameters were determined by means of dimensional analysis, and the generalized results for both the inner- and the outer-race bearing operating temperatures are computed for the laboratory test rig and the turbojet engine. A method is given that enables the designer to predict the inner- and outer-race turbine roller-bearing temperatures from single curves, regardless of variations in speed, load, oil flow, oil inlet temperature, oil inlet viscosity, oil-jet diameter, or any combination of these parameters.

  9. 27 CFR 22.107 - Pathological laboratories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Pathological laboratories... Pathological laboratories. (a) Pathological laboratories, not operated by a hospital or sanitarium, may... sanitariums. If a pathological laboratory does not exclusively conduct analyses or tests for hospitals or...

  10. 27 CFR 22.107 - Pathological laboratories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Pathological laboratories... Pathological laboratories. (a) Pathological laboratories, not operated by a hospital or sanitarium, may... sanitariums. If a pathological laboratory does not exclusively conduct analyses or tests for hospitals or...

  11. Pacific Northwest Laboratory annual report for 1988 to the DOE Office of Energy Research: Part 1, Biomedical Sciences

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, J.F.

    1989-06-01

    This report summarizes progress on OHER biomedical and health-effects research conducted at PNL in FY 1988. The research develops the knowledge and scientific principles necessary to identify, understand, and anticipate the long-term health consequences of energy-related radiation and chemicals. Our continuing emphasis is to decrease the uncertainty of health-effects risk estimates from existing and/or developing energy-related technologies through an increased understanding of how radiation and chemicals cause health effects. The report is arranged to reflect PNL research relative to OHER programmatic structure. The first section, on human health effects, concerns statistical and epidemiological studies for assessing health risks. The nextmore » section, which contains reports of health-effects research in biological systems, includes research with radiation and chemicals.« less

  12. Microbial ecology laboratory procedures manual NASA/MSFC

    NASA Technical Reports Server (NTRS)

    Huff, Timothy L.

    1990-01-01

    An essential part of the efficient operation of any microbiology laboratory involved in sample analysis is a standard procedures manual. The purpose of this manual is to provide concise and well defined instructions on routine technical procedures involving sample analysis and methods for monitoring and maintaining quality control within the laboratory. Of equal importance is the safe operation of the laboratory. This manual outlines detailed procedures to be followed in the microbial ecology laboratory to assure safety, analytical control, and validity of results.

  13. Developing a lean culture in the laboratory.

    PubMed

    Napoles, Leyda; Quintana, Maria

    2006-07-25

    The Director of Pathology at Jackson Memorial Hospital was interested in improving the operational efficiencies of the department in order to enhance the department's level of service in conjunction with the expansion of the overall health system. The decision was made to implement proven Lean practices in the laboratory under the direction of a major consulting firm. This article details the scope of the initial project as well as the operating principles of Lean manufacturing practices as applied to the clinical laboratory. The goals of the project were to improve turnaround times of laboratory results, reduce inventory and supply costs, improve staff productivity, maximize workflow, and eliminate waste. Extensive data gathering and analysis guided the work process by highlighting the areas of highest opportunity. This systematic approach resulted in recommendations for the workflow and physical layout of the laboratory. It also included the introduction of "standard workflow" and "visual controls" as critical items that streamlined operational efficiencies. The authors provide actual photographs and schematics of the reorganization and improvements to the physical layout of the laboratory. In conclusion, this project resulted in decreased turnaround times and increased productivity, as well as significant savings in the overall laboratory operations.

  14. Cost analysis in the toxicology laboratory.

    PubMed

    Travers, E M

    1990-09-01

    The process of determining laboratory sectional and departmental costs and test costs for instrument-generated and manually generated reportable results for toxicology laboratories has been outlined in this article. It is hoped that the basic principles outlined in the preceding text will clarify and elucidate one of the most important areas needed for laboratory fiscal integrity and its survival in these difficult times for health care providers. The following general principles derived from this article are helpful aids for managers of toxicology laboratories. 1. To manage a cost-effective, efficient toxicology laboratory, several factors must be considered: the laboratory's instrument configuration, test turnaround time needs, the test menu offered, the analytic methods used, the cost of labor based on time expended and the experience and educational level of the staff, and logistics that determine specimen delivery time and costs. 2. There is a wide variation in costs for toxicologic methods, which requires that an analysis of capital (equipment) purchase and operational (test performance) costs be performed to avoid waste, purchase wisely, and determine which tests consume the majority of the laboratory's resources. 3. Toxicologic analysis is composed of many complex steps. Each step must be individually cost-accounted. Screening test results must be confirmed, and the cost for both steps must be included in the cost per reportable result. 4. Total costs will vary in the same laboratory and between laboratories based on differences in salaries paid to technical staff, differences in reagent/supply costs, the number of technical staff needed to operate the analyzer or perform the method, and the inefficient use of highly paid staff to operate the analyzer or perform the method. 5. Since direct test costs vary directly with the type and number of analyzers or methods and are dependent on the operational mode designed by the manufacturer, laboratory managers

  15. Investigation of self-help oil-spill response techniques and equipment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Enderlin, W I; Downing, J P; Enderlin, C W

    1992-06-01

    The US Coast Guard commissioned Pacific Northwest Laboratory (PNL) to conduct this study of 45 self-help oil-spill response techniques and equipment for oceangoing tankers and inland tank barges to assess the potential effectiveness of the proposed countermeasure categories. This study considers the hypothetical outflow of oil in the case of side damage and bottom damage to single-hull designs. The results will be considered by the Coast Guard in drafting regulations pertaining to the requirement for tanker vessels to carry oil pollution response equipment (i.e., in response to the oil Pollution Act of 1990). PNL's approach to this investigation included: assessingmore » time-dependent oil outflow in the cases of collision and grounding of both tankers and barges; identifying environmental constraints on self-help countermeasure operation; identifying human factor issues, such as crew performance, safety, and training requirements for the self-help countermeasures considered; and assessing each self-help countermeasure with respect to its potential for minimizing oil loss to the environment. Results from the time-dependent oil outflow, environmental limitations, and human factors requirements were input into a simulation model.« less

  16. A laboratory study of subjective annoyance response to sonic booms and aircraft flyovers

    NASA Technical Reports Server (NTRS)

    Leatherwood, Jack D.; Sullivan, Brenda M.

    1994-01-01

    Three experiments were conducted to determine subjective equivalence of aircraft subsonic flyover noise and sonic booms. Two of the experiments were conducted in a loudspeaker-driven sonic boom simulator, and the third in a large room containing conventional loudspeakers. The sound generation system of the boom simulator had a frequency response extending to very low frequencies (about 1 Hz) whereas the large room loudspeakers were limited to about 20 Hz. Subjective equivalence between booms and flyovers was quantified in terms of the difference between the noise level of a boom and that of a flyover when the two were judged equally annoying. Noise levels were quantified in terms of the following noise descriptors: Perceived Level (PL), Perceived Noise Level (PNL), C-weighted sound exposure level (SELC), and A-weighted sound exposure level (SELA). Results from the present study were compared, where possible, to similar results obtained in other studies. Results showed that noise level differences depended upon the descriptor used, specific boom and aircraft noise events being compared and, except for the PNL descriptor, varied between the simulator and large room. Comparison of noise level differences obtained in the present study with those of other studies indicated good agreement across studies only for the PNL and SELA descriptors. Comparison of the present results with assessments of community response to high-energy impulsive sounds made by Working Group 84 of the National Research Council's Committee on Hearing, Bioacoustics, and Biomechanics (CHABA) showed good agreement when boom/flyover noise level differences were based on SELA. However, noise level differences obtained by CHABA using SELA for aircraft flyovers and SELC for booms were not in agreement with results obtained in the present study.

  17. Comparison of flexible ureterorenoscopy and mini-percutaneous nephrolithotomy in treatment of lower calyceal stones smaller than 2 cm.

    PubMed

    Akbulut, Fatih; Kucuktopcu, Onur; Kandemir, Emre; Sonmezay, Erkan; Simsek, Abdulmuttalip; Ozgor, Faruk; Binbay, Murat; Muslumanoglu, Ahmet Yaser; Gurbuz, Gokhan

    2016-01-01

    To compare the outcomes of flexible ureterorenoscopy (F-URS) and mini-percutaneous nephrolithotomy (mini-PNL) in the treatment of lower calyceal stones smaller than 2 cm. Patients who underwent F-URS and mini-PNL for the treatment of lower calyceal stones smaller than 2 cm between March 2009 and December 2014 were retrospectively evaluated. Ninety-four patients were divided into two groups by treatment modality: F-URS (Group 1: 63 patients) and mini-PNL (Group 2: 31 patients). All patients were preoperatively diagnosed with intravenous pyelography or computed tomography. Success rates for F-URS and mini-PNL at postoperative first month were 85.7% and 90.3%, respectively. Operation time, fluoroscopy time, and hospitalization time for F-URS and mini-PNL patients were 44.40 min, 2.9 min, 22.4 h, and 91.9 min, 6.4 min, and 63.8 h, respectively. All three parameters were significantly shorter among the F-URS group (p < 0.001). Postoperative hemoglobin drop was significantly lower in F-URS group compared to mini-PNL group (0.39 mg/dL vs. 1.15 mg/dL, p = 0.001). A comparison of complications according to the Clavien classification demonstrated significant differences between the groups (p = 0.001). More patients in the F-URS groups require antibiotics due to urinary tract infection, and more patients in the mini-PNL group required ureteral double J catheter insertion under general anesthesia. Although both F-URS and mini-PNL have similar success rates for the treatment of lower calyceal stones, F-URS appears to be more favorable due to shorter fluoroscopy and hospitalization times; and lower hemoglobin drops. Multicenter and studies using higher patient volumes are needed to confirm these findings.

  18. About the Frederick National Laboratory for Cancer Research | Frederick National Laboratory for Cancer Research

    Cancer.gov

    The Frederick National Laboratory is a Federally Funded Research and Development Center (FFRDC) sponsored by the National Cancer Institute (NCI) and currently operated by Leidos Biomedical Research, Inc. The laboratory addresses some of the most urge

  19. Operation of Grid-tied 5 kWDC solar array to develop Laboratory Experiments for Solar PV Energy System courses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramos, Jaime

    2012-12-14

    To unlock the potential of micro grids we plan to build, commission and operate a 5 kWDC PV array and integrate it to the UTPA Engineering building low voltage network, as a micro grid; and promote community awareness. Assisted by a solar radiation tracker providing on-line information of its measurements and performing analysis for the use by the scientific and engineering community, we will write, perform and operate a set of Laboratory experiments and computer simulations supporting Electrical Engineering (graduate and undergraduate) courses on Renewable Energy, as well as Senior Design projects.

  20. The stem cell laboratory: design, equipment, and oversight.

    PubMed

    Wesselschmidt, Robin L; Schwartz, Philip H

    2011-01-01

    This chapter describes some of the major issues to be considered when setting up a laboratory for the culture of human pluripotent stem cells (hPSCs). The process of establishing a hPSC laboratory can be divided into two equally important parts. One is completely administrative and includes developing protocols, seeking approval, and establishing reporting processes and documentation. The other part of establishing a hPSC laboratory involves the physical plant and includes design, equipment and personnel. Proper planning of laboratory operations and proper design of the physical layout of the stem cell laboratory so that meets the scope of planned operations is a major undertaking, but the time spent upfront will pay long-term returns in operational efficiency and effectiveness. A well-planned, organized, and properly equipped laboratory supports research activities by increasing efficiency and reducing lost time and wasted resources.

  1. LANGUAGE ARTS LABORATORY.

    ERIC Educational Resources Information Center

    ROBERTS, HERMESE E.

    THE LANGUAGE ARTS LABORATORY WAS ESTABLISHED TO IMPROVE READING ABILITY AND OTHER LANGUAGE ARTS SKILLS AS AN AID IN THE PREVENTION OF DROPOUTS. THE LABORATORY WAS OPERATED ON A SUMMER SCHEDULE WITH A FLEXIBLE PROGRAM OF FROM 45 MINUTES TO 2 1/2 HOURS DAILY. ALL PUPILS WERE 14 YEARS OF AGE OR OLDER, AND EXPRESSED A DESIRE TO IMPROVE THEIR READING…

  2. Creep Laboratory manual

    NASA Astrophysics Data System (ADS)

    Osgerby, S.; Loveday, M. S.

    1992-06-01

    A manual for the NPL Creep Laboratory, a collective name given to two testing laboratories, the Uniaxial Creep Laboratory and the Advanced High Temperature Mechanical Testing Laboratory, is presented. The first laboratory is devoted to uniaxial creep testing and houses approximately 50 high sensitivity creep machines including 10 constant stress cam lever machines. The second laboratory houses a low cycle fatigue testing machine of 100 kN capacity driven by a servo-electric actuator, five machines for uniaxial tensile creep testing of engineering ceramics at temperatures up to 1600C, and an electronic creep machine. Details of the operational procedures for carrying out uniaxial creep testing are given. Calibration procedures to be followed in order to comply with the specifications laid down by British standards, and to provide traceability back to the primary standards are described.

  3. Pacific Northwest Laboratory annual report for 1985 to the DOE Office of Energy Research. Part 1. Biomedical sciences

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, J.F.

    1986-02-01

    This report summarizes progress on OHER biomedical and health-effects research conducted at PNL in FY 1985 to develop information for a comprehensive understanding of the interaction of energy-related radiation and chemicals with man. Our continuing emphasis on decreasing the uncertainty of health-effects risk estimates to man from existing and/or developing energy-related technologies supports the DOE goal of increasing and diversifying national energy resources and decreasing risks to human health. The report is arranged to reflect the PNL research relative to OHER programmatic needs. The first section concerns evaluation of possible health effects among nuclear workers. The next two sections, whichmore » contain reports of health-effects research in biological systems, include health effects of radiation and health effects of chemical mixtures. The last section is related to medical applications of nuclear technology.« less

  4. Justification of parameters and selection of equipment for laboratory researches of a rammer's operating element dynamics in a soil foundation of a tank for oil and oil products storage

    NASA Astrophysics Data System (ADS)

    Gruzin, A. V.; Gruzin, V. V.; Shalay, V. V.

    2017-08-01

    The development of technology for a directional soil compaction of tank foundations for oil and oil products storage is a relevant problem which solution will enable simultaneously provide required operational characteristics of a soil foundation and reduce time and material costs to prepare the foundation. The impact dynamics of rammers' operating elements on the soil foundation is planned to specify in the course of laboratory studies. A specialized technique is developed to justify the parameters and select the equipment for laboratory researches. The usage of this technique enabled us to calculate dimensions of the models, of a test bench and specifications of the recording equipment, and a lighting system. The necessary equipment for laboratory studies was selected. Preliminary laboratory tests were carried out. The estimate of accuracy for planned laboratory studies was given.

  5. Components of laboratory accreditation.

    PubMed

    Royal, P D

    1995-12-01

    Accreditation or certification is a recognition given to an operation or product that has been evaluated against a standard; be it regulatory or voluntary. The purpose of accreditation is to provide the consumer with a level of confidence in the quality of operation (process) and the product of an organization. Environmental Protection Agency/OCM has proposed the development of an accreditation program under National Environmental Laboratory Accreditation Program for Good Laboratory Practice (GLP) laboratories as a supplement to the current program. This proposal was the result of the Inspector General Office reports that identified weaknesses in the current operation. Several accreditation programs can be evaluated and common components identified when proposing a structure for accrediting a GLP system. An understanding of these components is useful in building that structure. Internationally accepted accreditation programs provide a template for building a U.S. GLP accreditation program. This presentation will discuss the traditional structure of accreditation as presented in the Organization of Economic Cooperative Development/GLP program, ISO-9000 Accreditation and ISO/IEC Guide 25 Standard, and the Canadian Association for Environmental Analytical Laboratories, which has a biological component. Most accreditation programs are managed by a recognized third party, either privately or with government oversight. Common components often include a formal review of required credentials to evaluate organizational structure, a site visit to evaluate the facility, and a performance evaluation to assess technical competence. Laboratory performance is measured against written standards and scored. A formal report is then sent to the laboratory indicating accreditation status. Usually, there is a scheduled reevaluation built into the program. Fee structures vary considerably and will need to be examined closely when building a GLP program.

  6. The Stem Cell Laboratory: Design, Equipment, and Oversight

    PubMed Central

    Wesselschmidt, Robin L.; Schwartz, Philip H.

    2013-01-01

    This chapter describes some of the major issues to be considered when setting up a laboratory for the culture of human pluripotent stem cells (hPSCs). The process of establishing a hPSC laboratory can be divided into two equally important parts. One is completely administrative and includes developing protocols, seeking approval, and establishing reporting processes and documentation. The other part of establishing a hPSC laboratory involves the physical plant and includes design, equipment and personnel. Proper planning of laboratory operations and proper design of the physical layout of the stem cell laboratory so that meets the scope of planned operations is a major undertaking, but the time spent upfront will pay long-term returns in operational efficiency and effectiveness. A well-planned, organized, and properly equipped laboratory supports research activities by increasing efficiency and reducing lost time and wasted resources. PMID:21822863

  7. Use of fine needle aspirate from peripheral nerves of pure-neural leprosy for cytology and PCR to confirm the diagnosis: a pilot study.

    PubMed

    Reja, Abu Hena Hasanoor; De, Abhishek; Biswas, Supratik; Chattopadhyay, Amitabha; Chatterjee, Gobinda; Bhattacharya, Basudev; Sarda, Aarti; Aggarwal, Ishad

    2013-01-01

    The diagnosis of pure neural leprosy (PNL) remained subjective because of over-dependence of clinical expertise and a lack of simple yet reliable diagnostic tool. The criteria for diagnosis, proposed by Jardim et al., are not routinely done by clinicians in developing country as it involves invasive nerve biopsy and sophisticated anti-PGL-1 detection. We conducted a study using fine needle aspiration cytology (FNAC) coupled with Ziehl Neelsen staining (ZN staining) and Multiplex-Polymerase Chain Reaction (PCR) specific for M. leprae for an objective diagnosis of pure neural leprosy (PNL), which may be simpler and yet reliable. The aim of the study is to couple FNAC with ZN staining and multiplex PCR to diagnose pure neural leprosy patients rapidly, in simpler and yet reliable way. Thirteen patients of PNL as diagnosed by two independent consultants were included as case, and 5 patients other than PNL were taken as control in the study. Fine needle aspiration was done on the affected nerve, and aspirates were evaluated for cytology, ZN staining and multiplex-PCR. Out of the 13 cases where fine needle aspiration was done, M. leprae could be elicited in the nerve tissue aspirates in 5 cases (38.4%) with the help of conventional acid-fast staining and 11 cases (84.6%) with the help of multiplex PCR. On cytological examination of the aspirates, only 3 (23%) cases showed specific epithelioid cells, whereas 8 (61.5%) cases showed non-specific inflammation, and 2 (15.3%) cases had no inflammatory cells. Our study demonstrates that in the field of laboratory diagnosis of PNL cases, FNAC in combination with ZN staining for acid-fast bacilli (AFB) and Multiplex-PCR can provide a rapid and definitive diagnosis for the majority of PNL cases. FNAC is a less-invasive, outdoor-based and simpler technique than invasive nerve biopsy procedure. Thus, this study may enlighten the future path for easy and reliable diagnosis of PNL.

  8. EPA LABORATORIES IMPLEMENT EMS PROGRAM

    EPA Science Inventory

    This paper highlights the breadth and magnitude of carrying out an effective Environmental Management System (EMS) program at the U.S. EPA's research and development laboratories. Federal research laboratories have unique operating challenges compared to more centralized industr...

  9. Performances of condensation boilers of the dry type observed in the laboratory and in operation (in French)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pelloux-Prayer, D.; Rottenberg, J.; Ours, A.

    1982-01-01

    Studies have shown that the dry type of condensation boiler offers substantial energy savings in residential space heating. For collective heating, laboratory efficiencies of 85-95% were confirmed in the field by a condensation boiler operating in a 75-unit apartment house. Compared with conventional boilers, the condensation type uses 15-21% less energy. Retrofitting existing boilers involves routing the flue gas through a heat exchanger placed in the return-water system and providing drainage for the condensates.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gillespie, B.M.; Stromatt, R.W.; Ross, G.A.

    This data package contains the results obtained by Pacific Northwest Laboratory (PNL) staff in the characterization of samples for the 101-SY Hydrogen Safety Project. The samples were submitted for analysis by Westinghouse Hanford Company (WHC) under the Technical Project Plan (TPP) 17667 and the Quality Assurance Plan MCS-027. They came from a core taken during Window C'' after the May 1991 gas release event. The analytical procedures required for analysis were defined in the Test Instructions (TI) prepared by the PNL 101-SY Analytical Chemistry Laboratory (ACL) Project Management Office in accordance with the TPP and the QA Plan. The requestedmore » analysis for these samples was volatile organic analysis. The quality control (QC) requirements for each sample are defined in the Test Instructions for each sample. The QC requirements outlined in the procedures and requested in the WHC statement of work were followed.« less

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gillespie, B.M.; Stromatt, R.W.; Ross, G.A.

    This data package contains the results obtained by Pacific Northwest Laboratory (PNL) staff in the characterization of samples for the 101-SY Hydrogen Safety Project. The samples were submitted for analysis by Westinghouse Hanford Company (WHC) under the Technical Project Plan (TPP) 17667 and the Quality Assurance Plan MCS-027. They came from a core taken during Window ``C`` after the May 1991 gas release event. The analytical procedures required for analysis were defined in the Test Instructions (TI) prepared by the PNL 101-SY Analytical Chemistry Laboratory (ACL) Project Management Office in accordance with the TPP and the QA Plan. The requestedmore » analysis for these samples was volatile organic analysis. The quality control (QC) requirements for each sample are defined in the Test Instructions for each sample. The QC requirements outlined in the procedures and requested in the WHC statement of work were followed.« less

  12. The Evolution of the Language Laboratory: Changes During Fifteen Years of Operation

    ERIC Educational Resources Information Center

    Stack, Edward M.

    1977-01-01

    This article summarizes conditions and changes in language laboratories. Types of laboratories and equipment are listed; laboratory personnel include technicians, librarians and student assistants. Most maintenance was done by institution personnel; student use is outlined. Professional attitudes and equipment statistics are surveyed. (CHK)

  13. Self Audits of Hazardous Waste Operations in Laboratories.

    ERIC Educational Resources Information Center

    Fischer, Kenneth E.

    1987-01-01

    Discusses the need for compliance with state and federal regulations regarding the handling of hazardous wastes in college chemistry laboratories. Addresses: (1) waste determination; (2) facility requirements; (3) use of the manifest, vendor, transporter, site selection requirements, and training; (4) contingency planning; and (5) documentation.…

  14. Clinical laboratory as an economic model for business performance analysis.

    PubMed

    Buljanović, Vikica; Patajac, Hrvoje; Petrovecki, Mladen

    2011-08-15

    To perform SWOT (strengths, weaknesses, opportunities, and threats) analysis of a clinical laboratory as an economic model that may be used to improve business performance of laboratories by removing weaknesses, minimizing threats, and using external opportunities and internal strengths. Impact of possible threats to and weaknesses of the Clinical Laboratory at Našice General County Hospital business performance and use of strengths and opportunities to improve operating profit were simulated using models created on the basis of SWOT analysis results. The operating profit as a measure of profitability of the clinical laboratory was defined as total revenue minus total expenses and presented using a profit and loss account. Changes in the input parameters in the profit and loss account for 2008 were determined using opportunities and potential threats, and economic sensitivity analysis was made by using changes in the key parameters. The profit and loss account and economic sensitivity analysis were tools for quantifying the impact of changes in the revenues and expenses on the business operations of clinical laboratory. Results of simulation models showed that operational profit of €470 723 in 2008 could be reduced to only €21 542 if all possible threats became a reality and current weaknesses remained the same. Also, operational gain could be increased to €535 804 if laboratory strengths and opportunities were utilized. If both the opportunities and threats became a reality, the operational profit would decrease by €384 465. The operational profit of the clinical laboratory could be significantly reduced if all threats became a reality and the current weaknesses remained the same. The operational profit could be increased by utilizing strengths and opportunities as much as possible. This type of modeling may be used to monitor business operations of any clinical laboratory and improve its financial situation by implementing changes in the next fiscal

  15. Geomorphologic Modeling of a Macro-Tidal Embayment With Extensive Tidal Flats: Skagit Bay, WA

    DTIC Science & Technology

    2009-01-01

    Tidal Flats: Skagit Bay , WA Lyle Hibler Pacific Northwest National Laboratory 1529 West Sequim Bay Road Sequim , WA 98382 phone: (360) 681...3616 fax: (360) 681-3681 email: lyle.hibler@pnl.gov Adam Maxwell Pacific Northwest National Laboratory 1529 West Sequim Bay Road Sequim , WA... Sequim Bay Road, Sequim ,WA,98382 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR

  16. Geomorphologic Modeling of a Macro-tidal Embayment with Extensive Tidal Flats: Skagit Bay, WA

    DTIC Science & Technology

    2008-01-01

    Bay , WA Lyle Hibler Pacific Northwest National Laboratory 1529 West Sequim Bay Road Sequim , WA 98382 phone: (360) 681-3616 fax: (360)681-3681...email: lyle.hibler@pnl.gov Adam Maxwell Pacific Northwest National Laboratory 1529 West Sequim Bay Road Sequim , WA 98382 phone: (360) 681... Sequim Bay Road, Sequim ,WA,98382 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10.

  17. National Laboratory Planning: Developing Sustainable Biocontainment Laboratories in Limited Resource Areas.

    PubMed

    Yeh, Kenneth B; Adams, Martin; Stamper, Paul D; Dasgupta, Debanjana; Hewson, Roger; Buck, Charles D; Richards, Allen L; Hay, John

    2016-01-01

    Strategic laboratory planning in limited resource areas is essential for addressing global health security issues. Establishing a national reference laboratory, especially one with BSL-3 or -4 biocontainment facilities, requires a heavy investment of resources, a multisectoral approach, and commitments from multiple stakeholders. We make the case for donor organizations and recipient partners to develop a comprehensive laboratory operations roadmap that addresses factors such as mission and roles, engaging national and political support, securing financial support, defining stakeholder involvement, fostering partnerships, and building trust. Successful development occurred with projects in African countries and in Azerbaijan, where strong leadership and a clear management framework have been key to success. A clearly identified and agreed management framework facilitate identifying the responsibility for developing laboratory capabilities and support services, including biosafety and biosecurity, quality assurance, equipment maintenance, supply chain establishment, staff certification and training, retention of human resources, and sustainable operating revenue. These capabilities and support services pose rate-limiting yet necessary challenges. Laboratory capabilities depend on mission and role, as determined by all stakeholders, and demonstrate the need for relevant metrics to monitor the success of the laboratory, including support for internal and external audits. Our analysis concludes that alternative frameworks for success exist for developing and implementing capabilities at regional and national levels in limited resource areas. Thus, achieving a balance for standardizing practices between local procedures and accepted international standards is a prerequisite for integrating new facilities into a country's existing public health infrastructure and into the overall international scientific community.

  18. National Laboratory Planning: Developing Sustainable Biocontainment Laboratories in Limited Resource Areas

    PubMed Central

    Adams, Martin; Stamper, Paul D.; Dasgupta, Debanjana; Hewson, Roger; Buck, Charles D.; Richards, Allen L.; Hay, John

    2016-01-01

    Strategic laboratory planning in limited resource areas is essential for addressing global health security issues. Establishing a national reference laboratory, especially one with BSL-3 or -4 biocontainment facilities, requires a heavy investment of resources, a multisectoral approach, and commitments from multiple stakeholders. We make the case for donor organizations and recipient partners to develop a comprehensive laboratory operations roadmap that addresses factors such as mission and roles, engaging national and political support, securing financial support, defining stakeholder involvement, fostering partnerships, and building trust. Successful development occurred with projects in African countries and in Azerbaijan, where strong leadership and a clear management framework have been key to success. A clearly identified and agreed management framework facilitate identifying the responsibility for developing laboratory capabilities and support services, including biosafety and biosecurity, quality assurance, equipment maintenance, supply chain establishment, staff certification and training, retention of human resources, and sustainable operating revenue. These capabilities and support services pose rate-limiting yet necessary challenges. Laboratory capabilities depend on mission and role, as determined by all stakeholders, and demonstrate the need for relevant metrics to monitor the success of the laboratory, including support for internal and external audits. Our analysis concludes that alternative frameworks for success exist for developing and implementing capabilities at regional and national levels in limited resource areas. Thus, achieving a balance for standardizing practices between local procedures and accepted international standards is a prerequisite for integrating new facilities into a country's existing public health infrastructure and into the overall international scientific community. PMID:27559843

  19. Strengths of the Northwell Health Laboratory Service Line

    PubMed Central

    Balfour, Erika; Stallone, Robert; Castagnaro, Joseph; Poczter, Hannah; Schron, Deborah; Martone, James; Breining, Dwayne; Simpkins, Henry; Neglia, Tom; Kalish, Paul

    2016-01-01

    From 2009 to 2015, the laboratories of the 19-hospital North Shore-LIJ Health System experienced 5 threatened interruptions in service and supported 2 regional health-care providers with threatened interruptions in their laboratory service. We report our strategies to maintain laboratory performance during these events, drawing upon the strengths of our integrated laboratory service line. Established in 2009, the laboratory service line has unified medical and administrative leadership and system-wide divisional structure, quality management, and standardization of operations and procedures. Among many benefits, this governance structure enabled the laboratories to respond to a series of unexpected events. Specifically, at our various service sites, the laboratories dealt with pandemic (2009), 2 floods (2010, 2012), 2 fires (2010, 2015), and laboratory floor subsidence (2013). We were also asked to provide support for a regional physician network facing abrupt loss of testing services from closure of another regional clinical laboratory (2010) and to intervene for a non-health system hospital threatened with closure owing to noncompliance of laboratory operations (2012). In all but a single instance, patient care was served without interruption in service. In the last instance, fire interrupted laboratory services for 30 minutes. We conclude that in a large integrated health system, threats to continuous laboratory operations are not infrequent when measured on an annual basis. While most threats are from external physical circumstances, some emanate from unexpected administrative events. A strong laboratory governance mechanism that includes unified medical and administrative leadership across the entirety of the laboratory service line enables successful responses to these threats. PMID:28725768

  20. GREEN RIVER AIR QUALITY MODEL DEVELOPMENT: METEOROGICAL AND TRACER DATA-FIELD STUDY IN BRUSH VALLEY, COLORADO, JULY-AUGUST, 1982

    EPA Science Inventory

    Special meteorological and atmospheric tracer studies were conducted during a three-week period in July and August of 1982 in the Brush Creek Valley of northwestern Colorado. The experiments were conducted by the U.S. Department of Energy's Pacific Northwest Laboratory (PNL) as p...

  1. Commercialization of a DOE Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stephenson, Barry A.

    2008-01-15

    On April 1, 1998, Materials and Chemistry Laboratory, Inc. (MCLinc) began business as an employee-owned, commercial, applied research laboratory offering services to both government and commercial clients. The laboratory had previously been a support laboratory to DoE's gaseous diffusion plant in Oak Ridge (K-25). When uranium enrichment was halted at the site, the laboratory was expanded to as an environmental demonstration center and served from 1992 until 1997 as a DOE Environmental User Facility. In 1997, after the laboratory was declared surplus, it was made available to the employee group who operated the laboratory for DOE as a government-owned, contractor-operatedmore » facility. This paper describes briefly the process of establishing the business. Attributes that contributed to the success of MCLinc are described. Some attention is given to lessons learned and to changes that could facilitate future attempts to make similar transitions. Lessons learnt: as with any business venture, operation over time has revealed that some actions taken by the laboratory founders have contributed to its successful operation while others were not so successful. Observations are offered in hopes that lessons learned may suggest actions that will facilitate future attempts to make similar transitions. First, the decision to vest significant ownership of the business in the core group of professionals operating the business is key to its success. Employee-owners of the laboratory have consistently provided a high level of service to its customers while conducting business in a cost-efficient manner. Secondly, an early decision to provide business support services in-house rather than purchasing them from support contractors on site have proven cost-effective. Laboratory employees do multiple tasks and perform overhead tasks in addition to their chargeable technical responsibilities. Thirdly, assessment of technical capabilities in view of market needs and a decision to

  2. In-Situ Operations and Planning for the Mars Science Laboratory Robotic Arm: The First 200 Sols

    NASA Technical Reports Server (NTRS)

    Robinson, M.; Collins, C.; Leger, P.; Carsten, J.; Tompkins, V.; Hartman, F.; Yen, J.

    2013-01-01

    The Robotic Arm (RA) has operated for more than 200 Martian solar days (or sols) since the Mars Science Laboratory rover touched down in Gale Crater on August 5, 2012. During the first seven months on Mars the robotic arm has performed multiple contact science sols including the positioning of the Alpha Particle X-Ray Spectrometer (APXS) and/or Mars Hand Lens Imager (MAHLI) with respect to rocks or loose regolith targets. The RA has supported sample acquisition using both the scoop and drill, sample processing with CHIMRA (Collection and Handling for In- Situ Martian Rock Analysis), and delivery of sample portions to the observation tray, and the SAM (Sample Analysis at Mars) and CHEMIN (Chemistry and Mineralogy) science instruments. This paper describes the planning and execution of robotic arm activities during surface operations, and reviews robotic arm performance results from Mars to date.

  3. Policies and practices pertaining to the selection, qualification requirements, and training programs for nuclear-reactor operating personnel at the Oak Ridge National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Culbert, W.H.

    1985-10-01

    This document describes the policies and practices of the Oak Ridge National Laboratory (ORNL) regarding the selection of and training requirements for reactor operating personnel at the Laboratory's nuclear-reactor facilities. The training programs, both for initial certification and for requalification, are described and provide the guidelines for ensuring that ORNL's research reactors are operated in a safe and reliable manner by qualified personnel. This document gives an overview of the reactor facilities and addresses the various qualifications, training, testing, and requalification requirements stipulated in DOE Order 5480.1A, Chapter VI (Safety of DOE-Owned Reactors); it is intended to be in compliancemore » with this DOE Order, as applicable to ORNL facilities. Included also are examples of the documentation maintained amenable for audit.« less

  4. Application of a prospective model for calculating worker exposure due to the air pathway for operations in a laboratory.

    PubMed

    Grimbergen, T W M; Wiegman, M M

    2007-01-01

    In order to arrive at recommendations for guidelines on maximum allowable quantities of radioactive material in laboratories, a proposed mathematical model was used for the calculation of transfer fractions for the air pathway. A set of incident scenarios was defined, including spilling, leakage and failure of the fume hood. For these 'common incidents', dose constraints of 1 mSv and 0.1 mSv are proposed in case the operations are being performed in a controlled area and supervised area, respectively. In addition, a dose constraint of 1 microSv is proposed for each operation under regular working conditions. Combining these dose constraints and the transfer fractions calculated with the proposed model, maximum allowable quantities were calculated for different laboratory operations and situations. Provided that the calculated transfer fractions can be experimentally validated and the dose constraints are acceptable, it can be concluded from the results that the dose constraint for incidents is the most restrictive one. For non-volatile materials this approach leads to quantities much larger than commonly accepted. In those cases, the results of the calculations in this study suggest that limitation of the quantity of radioactive material, which can be handled safely, should be based on other considerations than the inhalation risks. Examples of such considerations might be the level of external exposure, uncontrolled spread of radioactive material by surface contamination, emissions in the environment and severe accidents like fire.

  5. 1995 solid waste 30-year characteristics volume summary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Templeton, K.J.; DeForest, T.J.; Rice, G.I.

    1995-10-01

    The Hanford Site has been designated by the US Department of Energy (DOE) to store, treat, and dispose of solid waste received from both onsite and offsite generators. This waste is currently or planned to be generated from ongoing operations, maintenance and deactivation activities, decontamination and decommissioning (D&D) of facilities, and environmental restoration (ER) activities. This document, prepared by Pacific Northwest Laboratory (PNL) under the direction of Westinghouse Hanford Company (WHC), describes the characteristics of the waste to be shipped to Hanford`s SWOC. The physical waste forms and hazardous constituents are described for the low-level mixed waste (LLMW) and themore » transuranic - transuranic mixed waste (TW{underscore}TRUM).« less

  6. The "hospital central laboratory": automation, integration and clinical usefulness.

    PubMed

    Zaninotto, Martina; Plebani, Mario

    2010-07-01

    Recent technological developments in laboratory medicine have led to a major challenge, maintaining a close connection between the search of efficiency through automation and consolidation and the assurance of effectiveness. The adoption of systems that automate most of the manual tasks characterizing routine activities has significantly improved the quality of laboratory performance; total laboratory automation being the paradigm of the idea that "human-less" robotic laboratories may allow for better operation and insuring less human errors. Furthermore, even if ongoing technological developments have considerably improved the productivity of clinical laboratories as well as reducing the turnaround time of the entire process, the value of qualified personnel remains a significant issue. Recent evidence confirms that automation allows clinical laboratories to improve analytical performances only if trained staff operate in accordance with well-defined standard operative procedures, thus assuring continuous monitoring of the analytical quality. In addition, laboratory automation may improve the appropriateness of test requests through the use of algorithms and reflex testing. This should allow the adoption of clinical and biochemical guidelines. In conclusion, in laboratory medicine, technology represents a tool for improving clinical effectiveness and patient outcomes, but it has to be managed by qualified laboratory professionals.

  7. Analysis of the impact of safeguards criteria

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mullen, M.F.; Reardon, P.T.

    As part of the US Program of Technical Assistance to IAEA Safeguards, the Pacific Northwest Laboratory (PNL) was asked to assist in developing and demonstrating a model for assessing the impact of setting criteria for the application of IAEA safeguards. This report presents the results of PNL's work on the task. The report is in three parts. The first explains the technical approach and methodology. The second contains an example application of the methodology. The third presents the conclusions of the study. PNL used the model and computer programs developed as part of Task C.5 (Estimation of Inspection Efforts) ofmore » the Program of Technical Assistance. The example application of the methodology involves low-enriched uranium conversion and fuel fabrication facilities. The effects of variations in seven parameters are considered: false alarm probability, goal probability of detection, detection goal quantity, the plant operator's measurement capability, the inspector's variables measurement capability, the inspector's attributes measurement capability, and annual plant throughput. Among the key results and conclusions of the analysis are the following: the variables with the greatest impact on the probability of detection are the inspector's measurement capability, the goal quantity, and the throughput; the variables with the greatest impact on inspection costs are the throughput, the goal quantity, and the goal probability of detection; there are important interactions between variables. That is, the effects of a given variable often depends on the level or value of some other variable. With the methodology used in this study, these interactions can be quantitatively analyzed; reasonably good approximate prediction equations can be developed using the methodology described here.« less

  8. Hanford Laboratories monthly activities report, March 1964

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1964-04-15

    The monthly report for the Hanford Laboratories Operation, March 1964. Reactor fuels, chemistry, dosimetry, separation processes, reactor technology, financial activities, biology operation, and physics and instrumentation research, and applied mathematics operation, and programming operations are discussed.

  9. Theme: Land Laboratories--Urban Settings, Liability, Natural Resources Labs.

    ERIC Educational Resources Information Center

    Whaley, David, Ed.; And Others

    1994-01-01

    Includes "With a Little Imagination"; "From Fallow to Fertile"; "Operating a School Enterprise in Agriculture"; "Using a Nontraditional Greenhouse to Enhance Lab Instruction"; "Risk Management for Liability in Operating Land Laboratories"; "Working Land and Water Laboratory for Natural…

  10. A Performance-Based Training Qualification Guide/Checklist Developed for Reactor Operators at the High Flux Beam Reactor at Brookhaven National Laboratory.

    ERIC Educational Resources Information Center

    McNair, Robert C.

    A Performance-Based Training (PBT) Qualification Guide/Checklist was developed that would enable a trainee to attain the skills, knowledge, and attitude required to operate the High Flux Beam Reactor at Brookhaven National Laboratory. Design of this guide/checklist was based on the Instructional System Design Model. The needs analysis identified…

  11. Clinical laboratory as an economic model for business performance analysis

    PubMed Central

    Buljanović, Vikica; Patajac, Hrvoje; Petrovečki, Mladen

    2011-01-01

    Aim To perform SWOT (strengths, weaknesses, opportunities, and threats) analysis of a clinical laboratory as an economic model that may be used to improve business performance of laboratories by removing weaknesses, minimizing threats, and using external opportunities and internal strengths. Methods Impact of possible threats to and weaknesses of the Clinical Laboratory at Našice General County Hospital business performance and use of strengths and opportunities to improve operating profit were simulated using models created on the basis of SWOT analysis results. The operating profit as a measure of profitability of the clinical laboratory was defined as total revenue minus total expenses and presented using a profit and loss account. Changes in the input parameters in the profit and loss account for 2008 were determined using opportunities and potential threats, and economic sensitivity analysis was made by using changes in the key parameters. The profit and loss account and economic sensitivity analysis were tools for quantifying the impact of changes in the revenues and expenses on the business operations of clinical laboratory. Results Results of simulation models showed that operational profit of €470 723 in 2008 could be reduced to only €21 542 if all possible threats became a reality and current weaknesses remained the same. Also, operational gain could be increased to €535 804 if laboratory strengths and opportunities were utilized. If both the opportunities and threats became a reality, the operational profit would decrease by €384 465. Conclusion The operational profit of the clinical laboratory could be significantly reduced if all threats became a reality and the current weaknesses remained the same. The operational profit could be increased by utilizing strengths and opportunities as much as possible. This type of modeling may be used to monitor business operations of any clinical laboratory and improve its financial situation by

  12. Lessons learned from new construction utility demand side management programs and their implications for implementing building energy codes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wise, B.K.; Hughes, K.R.; Danko, S.L.

    1994-07-01

    This report was prepared for the US Department of Energy (DOE) Office of Codes and Standards by the Pacific Northwest Laboratory (PNL) through its Building Energy Standards Program (BESP). The purpose of this task was to identify demand-side management (DSM) strategies for new construction that utilities have adopted or developed to promote energy-efficient design and construction. PNL conducted a survey of utilities and used the information gathered to extrapolate lessons learned and to identify evolving trends in utility new-construction DSM programs. The ultimate goal of the task is to identify opportunities where states might work collaboratively with utilities to promotemore » the adoption, implementation, and enforcement of energy-efficient building energy codes.« less

  13. FERRET-SAND II physics-dosimetry analysis for N Reactor Pressure Tubes 2954, 3053 and 1165 using a WIMS calculated input spectrum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McElroy, W.N.; Kellogg, L.S.; Matsumoto, W.Y.

    1988-05-01

    This report is in response to a request from Westinghouse Hanford Company (WHC) that the PNL National Dosimetry Center (NDC) perform physics-dosimetry analyses (E > MeV) for N Reactor Pressure Tubes 2954 and 3053. As a result of these analyses, and recommendations for additional studies, two physics-dosimetry re-evaluations for Pressure Tube 1165 were also accomplished. The primary objective of Pacific Northwest Laboratories' (PNL) National Dosimetry Center (NDC) physics-dosimetry work for N Reactor was to provide FERRET-SAND II physics-dosimetry results to assist in the assessment of neutron radiation-induced changes in the physical and mechanical properties of N Reactor pressure tubes. 15more » refs., 6 figs., 5 tabs.« less

  14. Operational Changes in a Shared Resource Laboratory with the Use of a Product Lifecycle Management Approach: A Case Study.

    PubMed

    Hexley, Philip; Smith, Victoria; Wall, Samantha

    2016-04-01

    Shared Resource Laboratories (SRLs) provide investigators access to necessary scientific and resource expertise to leverage complex technologies fully for advancing high-quality biomedical research in a cost-effective manner. At the University of Nebraska Medical Center, the Flow Cytometry Research Facility (FCRF) offered access to exceptional technology, but the methods of operation were outdated and unsustainable. Whereas technology has advanced and the institute has expanded, the operations at the facility remained unchanged for 35 yr. To rectify this, at the end of 2013, we took a product lifecycle management approach to affect large operational changes and align the services offered with the SRL goal of education, as well as to provide service to researchers. These disruptive operational changes took over 10 mo to complete and allowed for independent end-user acquisition of flow cytometry data. The results have been monitored for the past 12 mo. The operational changes have had a positive impact on the quality of research, increased investigator-facility interaction, reduced stress of facility staff, and increased overall use of the resources. This product lifecycle management approach to facility operations allowed us to conceive of, design, implement, and monitor effectively the changes at the FCRF. This approach should be considered by SRL management when faced with the need for operationally disruptive measures.

  15. Ultra-mini-percutaneous nephrolithotomy in pediatric nephrolithiasis: both low pressure and high efficiency.

    PubMed

    Dede, Onur; Sancaktutar, Ahmet Ali; Dağguli, Mansur; Utangaç, Mazhar; Baş, Okan; Penbegul, Necmettin

    2015-10-01

    The management of urolithiasis in children differs from adults because of anatomic and metabolic abnormalities. At present, various minimally invasive and invasive treatment strategies have been recommended to treat urinary tract Stones, including shock wave lithotripsy (SWL), standard percutaneous nephrolithotomy (PNL), mini-PNL, retrograde intrarenal surgery (RIRS), micro-PNL, and a new technique termed ultra-mini PNL (UMP). UMP is a new method for the treatment of kidney stones. The main difference between UMP and standard PNL or mini-PNL lies in the small access sheath and in its design. A 9.5F pediatric compact cystoscope was used (Figure). A major advantage of UMP is that it provides similar stone-free rates when compared with standard PNL, with lower intrarenal pressure than micro-PNL. The aim of the study was to determine the applicability and safety of UMP in the treatment of pediatric kidney stones. We retrospectively reviewed the files of 39 kidney stones in children who had undergone UMP between May 2011 and October 2014. The indications for UMP included stones resistant to SWL, stones requiring repeated sessions of SWL, and stones size larger than 20 mm. The study included 17 females and 22 males, with a mean age of 5.8 ± 4.6 years. The mean hemoglobin loss was 0.9 ± 0.6 mg/dL and none of the patients required a blood transfusion. The complication rate of the PNL procedure was 15.3% (n = 6). Complete clearance was achieved in 32 patients (82%) with UMP monotherapy, which increased to 34% (87.1%) 4 weeks after the operation. Management of urolithiasis necessitates a balance between stone clearance and morbidity related to the procedure. SWL often leads to persistent residual stones. The developing RIRS can minimize the risks associated with bleeding and visceral injury, but sometimes the abnormal pelvicaliceal anatomy and poor imaging of the flexible ureteroscopy may impact its success rate and applications. It has been reported that PNL can be

  16. User's manual for the BNW-II optimization code for dry/wet-cooled power plants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Braun, D.J.; Bamberger, J.A.; Braun, D.J.

    1978-05-01

    The User's Manual describes how to operate BNW-II, a computer code developed by the Pacific Northwest Laboratory (PNL) as a part of its activities under the Department of Energy (DOE) Dry Cooling Enhancement Program. The computer program offers a comprehensive method of evaluating the cost savings potential of dry/wet-cooled heat rejection systems. Going beyond simple ''figure-of-merit'' cooling tower optimization, this method includes such items as the cost of annual replacement capacity, and the optimum split between plant scale-up and replacement capacity, as well as the purchase and operating costs of all major heat rejection components. Hence the BNW-II code ismore » a useful tool for determining potential cost savings of new dry/wet surfaces, new piping, or other components as part of an optimized system for a dry/wet-cooled plant.« less

  17. Laboratory safety handbook

    USGS Publications Warehouse

    Skinner, E.L.; Watterson, C.A.; Chemerys, J.C.

    1983-01-01

    Safety, defined as 'freedom from danger, risk, or injury,' is difficult to achieve in a laboratory environment. Inherent dangers, associated with water analysis and research laboratories where hazardous samples, materials, and equipment are used, must be minimized to protect workers, buildings, and equipment. Managers, supervisors, analysts, and laboratory support personnel each have specific responsibilities to reduce hazards by maintaining a safe work environment. General rules of conduct and safety practices that involve personal protection, laboratory practices, chemical handling, compressed gases handling, use of equipment, and overall security must be practiced by everyone at all levels. Routine and extensive inspections of all laboratories must be made regularly by qualified people. Personnel should be trained thoroughly and repetitively. Special hazards that may involve exposure to carcinogens, cryogenics, or radiation must be given special attention, and specific rules and operational procedures must be established to deal with them. Safety data, reference materials, and texts must be kept available if prudent safety is to be practiced and accidents prevented or minimized.

  18. Application of the Toyota Production System improves core laboratory operations.

    PubMed

    Rutledge, Joe; Xu, Min; Simpson, Joanne

    2010-01-01

    To meet the increased clinical demands of our hospital expansion, improve quality, and reduce costs, our tertiary care, pediatric core laboratory used the Toyota Production System lean processing to reorganize our 24-hour, 7 d/wk core laboratory. A 4-month, consultant-driven process removed waste, led to a physical reset of the space to match the work flow, and developed a work cell for our random access analyzers. In addition, visual controls, single piece flow, standard work, and "5S" were instituted. The new design met our goals as reflected by achieving and maintaining improved turnaround time (TAT; mean for creatinine reduced from 54 to 23 minutes) with increased testing volume (20%), monetary savings (4 full-time equivalents), decreased variability in TAT, and better space utilization (25% gain). The project had the unanticipated consequence of eliminating STAT testing because our in-laboratory TAT for routine testing was less than our prior STAT turnaround goal. The viability of this approach is demonstrated by sustained gains and further PDCA (Plan, Do, Check, Act) improvements during the 4 years after completion of the project.

  19. Horizontal and vertical integration in hospital laboratories and the laboratory information system.

    PubMed

    Friedman, B A; Mitchell, W

    1990-09-01

    An understanding of horizontal and vertical integration and their quasi-integration variants is important for pathologists to formulate a competitive strategy for hospital clinical laboratories. These basic organizational concepts, in turn, are based on the need to establish control over critical laboratory inputs and outputs. The pathologist seeks greater control of mission-critical system inputs and outputs to increase the quality and efficiency of the laboratory operations. The LIS produces horizontal integration of the various hospital laboratories by integrating them vertically. Forward vertical quasi-integration of the laboratories is mediated primarily by the LIS through front-end valued-added features such as reporting of results and creating a long-term on-line test result archive. These features increase the value of the information product of pathology for clinicians and increase the cost of switching to another system. The LIS can also serve as a means for customizing the information product of the laboratories to appeal to new market segments such as hospital administrators.

  20. Development and Use of a Virtual NMR Facility

    NASA Astrophysics Data System (ADS)

    Keating, Kelly A.; Myers, James D.; Pelton, Jeffrey G.; Bair, Raymond A.; Wemmer, David E.; Ellis, Paul D.

    2000-03-01

    We have developed a "virtual NMR facility" (VNMRF) to enhance access to the NMR spectrometers in Pacific Northwest National Laboratory's Environmental Molecular Sciences Laboratory (EMSL). We use the term virtual facility to describe a real NMR facility made accessible via the Internet. The VNMRF combines secure remote operation of the EMSL's NMR spectrometers over the Internet with real-time videoconferencing, remotely controlled laboratory cameras, real-time computer display sharing, a Web-based electronic laboratory notebook, and other capabilities. Remote VNMRF users can see and converse with EMSL researchers, directly and securely control the EMSL spectrometers, and collaboratively analyze results. A customized Electronic Laboratory Notebook allows interactive Web-based access to group notes, experimental parameters, proposed molecular structures, and other aspects of a research project. This paper describes our experience developing a VNMRF and details the specific capabilities available through the EMSL VNMRF. We show how the VNMRF has evolved during a test project and present an evaluation of its impact in the EMSL and its potential as a model for other scientific facilities. All Collaboratory software used in the VNMRF is freely available from http://www.emsl.pnl.gov:2080/docs/collab.

  1. Reversible tetraplegia after percutaneous nephrostolithotomy and septic shock: a case of critical illness polyneuropathy and myopathy with acute onset and complete recovery

    PubMed Central

    2013-01-01

    Background Critical illness polyneuropathy (CIP) and critical illness myopathy (CIM) are complications causing weakness of respiratory and limb muscles in critically ill patients. As an important differential diagnosis of Guillain-Barré syndrome (GBS), CIP and CIM should be diagnosed with caution, after a complete clinical and laboratory examination. Although not uncommon in ICU, CIP and CIM as severe complications of percutaneous nephrostolithotomy (PNL) have not been documented in literature. Case presentation A 48-year-old Chinese woman was referred to our hospital, complaining of occasional pain in the right lower back for one month. Lithiasis was diagnosed by ultrasonographical and radiological examinations on the urinary system. PNL was indicated and performed. The patient developed CIP and CIM on the fourth day after PNL. Early recognition and treatment of the severe complications contributed to a satisfactory recovery of the patient. Conclusion This case expands our understanding of the complications of PNL and underscores the importance of differentiating CIP/CIM from GBS in case of such patients developing weakness after the treatment. Clinical characteristics and examination results should be carefully evaluated to make the diagnosis of CIP or CIM. Both anti-septic prophylaxis and control of hyperglycemia might be effective for the prevention of CIP or CIM; aggressive treatment on sepsis and multiple organ failure is considered to be the most effective measure to reduce the incidence of CIP/CIM. PMID:23409743

  2. Research on the Error Characteristics of a 110 kV Optical Voltage Transformer under Three Conditions: In the Laboratory, Off-Line in the Field and During On-Line Operation.

    PubMed

    Xiao, Xia; Hu, Haoliang; Xu, Yan; Lei, Min; Xiong, Qianzhu

    2016-08-16

    Optical voltage transformers (OVTs) have been applied in power systems. When performing accuracy performance tests of OVTs large differences exist between the electromagnetic environment and the temperature variation in the laboratory and on-site. Therefore, OVTs may display different error characteristics under different conditions. In this paper, OVT prototypes with typical structures were selected to be tested for the error characteristics with the same testing equipment and testing method. The basic accuracy, the additional error caused by temperature and the adjacent phase in the laboratory, the accuracy in the field off-line, and the real-time monitoring error during on-line operation were tested. The error characteristics under the three conditions-laboratory, in the field off-line and during on-site operation-were compared and analyzed. The results showed that the effect of the transportation process, electromagnetic environment and the adjacent phase on the accuracy of OVTs could be ignored for level 0.2, but the error characteristics of OVTs are dependent on the environmental temperature and are sensitive to the temperature gradient. The temperature characteristics during on-line operation were significantly superior to those observed in the laboratory.

  3. Comparison of High-Speed Operating Characteristics of Size 215 Cylindrical-Roller Bearings as Determined in Turbojet Engine and in Laboratory Test Rig

    NASA Technical Reports Server (NTRS)

    Macks, E Fred; Nemeth, Zolton N

    1951-01-01

    A comparison of the operating characteristics of 75-millimeter-bore (size 215) cylindrical-roller one-piece inner-race-riding cage-type bearings was made using a laboratory test rig and a turbojet engine. Cooling correlation parameters were determined by means of dimensional analysis, and the generalized results for both the inner- and outer-race bearing operating temperatures are compared for the laboratory test rig and the turbojet engine. Inner- and outer-race cooling-correlation curves were obtained for the turbojet-engine turbine-roller bearing with the same inner- and outer-race correlation parameters and exponents as those determined for the laboratory test-rig bearing. The inner- and outer-race turbine roller-bearing temperatures may be predicted from a single curve, regardless of variations in speed, load, oil flow, oil inlet temperature, oil inlet viscosity, oil-jet diameter or any combination of these parameters. The turbojet-engine turbine-roller-bearing inner-race temperatures were 30 to 60 F greater than the outer-race-maximum temperatures, the exact values depending on the operating condition and oil viscosity; these results are in contrast to the laboratory test-rig results where the inner-race temperatures were less than the outer-race-maximum temperatures. The turbojet-engine turbine-roller bearing, maximum outer-race circumferential temperature variation was approximately 30 F for each of the oils used. The effect of oil viscosity on inner- and outer-race turbojet-engine turbine-roller-bearing temperatures was found to be significant. With the lower viscosity oil (6x10(exp -7) reyns (4.9 centistokes) at 100 F; viscosity index, 83), the inner-race temperature was approximately 30 to 35 F less than with the higher viscosity oil (53x10(exp -7) reyns (42.8 centistokes) at 100 F; viscosity index, 150); whereas the outer-race-maximum temperatures were 12 to 28 F lower with the lower viscosity oil over the DN range investigated.

  4. Design and Implementation Issues for Modern Remote Laboratories

    ERIC Educational Resources Information Center

    Guimaraes, E. G.; Cardozo, E.; Moraes, D. H.; Coelho, P. R.

    2011-01-01

    The design and implementation of remote laboratories present different levels of complexity according to the nature of the equipments operated by the remote laboratory, the requirements imposed on the accessing computers, the network linking the user to the laboratory, and the type of experiments the laboratory supports. This paper addresses the…

  5. International Space Station Payload Operations Integration

    NASA Technical Reports Server (NTRS)

    Fanske, Elizabeth Anne

    2011-01-01

    The Payload Operations Integrator (POINT) plays an integral part in the Certification of Flight Readiness process for the Mission Operations Laboratory and the Payload Operations Integration Function that supports International Space Station Payload operations. The POINTs operate in support of the POIF Payload Operations Manager to bring together and integrate the Certification of Flight Readiness inputs from various MOL teams through maintaining an open work tracking log. The POINTs create monthly metrics for current and future payloads that the Payload Operations Integration Function supports. With these tools, the POINTs assemble the Certification of Flight Readiness package before a given flight, stating that the Mission Operations Laboratory is prepared to support it. I have prepared metrics for Increment 29/30, maintained the Open Work Tracking Logs for Flights ULF6 (STS-134) and ULF7 (STS-135), and submitted the Mission Operations Laboratory Certification of Flight Readiness package for Flight 44P to the Mission Operations Directorate (MOD/OZ).

  6. 46 CFR 164.012-12 - Recognized laboratory.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Recognized laboratory. 164.012-12 Section 164.012-12...: SPECIFICATIONS AND APPROVAL MATERIALS Interior Finishes for Merchant Vessels § 164.012-12 Recognized laboratory. A recognized laboratory is one which is operated as a nonprofit public service and is regularly...

  7. 46 CFR 164.012-12 - Recognized laboratory.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Recognized laboratory. 164.012-12 Section 164.012-12...: SPECIFICATIONS AND APPROVAL MATERIALS Interior Finishes for Merchant Vessels § 164.012-12 Recognized laboratory. A recognized laboratory is one which is operated as a nonprofit public service and is regularly...

  8. Sediment and erosion control laboratory facility expansion.

    DOT National Transportation Integrated Search

    2016-08-01

    The Sediment and Erosion Control Laboratory (SEC Lab), formerly the Hydraulics, Sedimentation, and : Erosion Control Laboratory, is operated by the Texas A&M Transportation Institutes Environment and : Planning Program. Performance evaluation prog...

  9. 21 CFR 58.81 - Standard operating procedures.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Testing Facilities Operation § 58.81 Standard operating procedures. (a) A testing facility shall have standard operating procedures in writing setting... following: (1) Animal room preparation. (2) Animal care. (3) Receipt, identification, storage, handling...

  10. 21 CFR 58.81 - Standard operating procedures.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Testing Facilities Operation § 58.81 Standard operating procedures. (a) A testing facility shall have standard operating procedures in writing setting... following: (1) Animal room preparation. (2) Animal care. (3) Receipt, identification, storage, handling...

  11. 21 CFR 58.81 - Standard operating procedures.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Testing Facilities Operation § 58.81 Standard operating procedures. (a) A testing facility shall have standard operating procedures in writing setting... following: (1) Animal room preparation. (2) Animal care. (3) Receipt, identification, storage, handling...

  12. 21 CFR 58.81 - Standard operating procedures.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Testing Facilities Operation § 58.81 Standard operating procedures. (a) A testing facility shall have standard operating procedures in writing setting... following: (1) Animal room preparation. (2) Animal care. (3) Receipt, identification, storage, handling...

  13. In-Flight Laboratory Analysis

    NASA Technical Reports Server (NTRS)

    Baumann, David; Perusek, Gail; Nelson, Emily; Krihak, Michael; Brown, Dan

    2012-01-01

    One-year study objectives align with HRP requirements. HRP requirements include measurement panels for research and medical operations - These measurement panels are distinctly different. Instrument requirements are defined - Power, volume and mass not quite a critical limitation as for medical operations (deep space exploration missions). One-year evaluation goals will lead HHC towards in-flight laboratory analysis capability.

  14. [Laboratory accreditation and proficiency testing].

    PubMed

    Kuwa, Katsuhiko

    2003-05-01

    ISO/TC 212 covering clinical laboratory testing and in vitro diagnostic test systems will issue the international standard for medical laboratory quality and competence requirements, ISO 15189. This standard is based on the ISO/IEC 17025, general requirements for competence of testing and calibration laboratories and ISO 9001, quality management systems-requirements. Clinical laboratory services are essential to patient care and therefore should be available to meet the needs of all patients and clinical personnel responsible for human health care. If a laboratory seeks accreditation, it should select an accreditation body that operates according to this international standard and in a manner which takes into account the particular requirements of clinical laboratories. Proficiency testing should be available to evaluate the calibration laboratories and reference measurement laboratories in clinical medicine. Reference measurement procedures should be of precise and the analytical principle of measurement applied should ensure reliability. We should be prepared to establish a quality management system and proficiency testing in clinical laboratories.

  15. Internal audit in a microbiology laboratory.

    PubMed Central

    Mifsud, A J; Shafi, M S

    1995-01-01

    AIM--To set up a programme of internal laboratory audit in a medical microbiology laboratory. METHODS--A model of laboratory based process audit is described. Laboratory activities were examined in turn by specimen type. Standards were set using laboratory standard operating procedures; practice was observed using a purpose designed questionnaire and the data were analysed by computer; performance was assessed at laboratory audit meetings; and the audit circle was closed by re-auditing topics after an interval. RESULTS--Improvements in performance scores (objective measures) and in staff morale (subjective impression) were observed. CONCLUSIONS--This model of process audit could be applied, with amendments to take local practice into account, in any microbiology laboratory. PMID:7665701

  16. Energy and Water Conservation Assessment of the Radiochemical Processing Laboratory (RPL) at Pacific Northwest National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Stephanie R.; Koehler, Theresa M.; Boyd, Brian K.

    2014-05-31

    This report summarizes the results of an energy and water conservation assessment of the Radiochemical Processing Laboratory (RPL) at Pacific Northwest National Laboratory (PNNL). The assessment was performed in October 2013 by engineers from the PNNL Building Performance Team with the support of the dedicated RPL staff and several Facilities and Operations (F&O) department engineers. The assessment was completed for the Facilities and Operations (F&O) department at PNNL in support of the requirements within Section 432 of the Energy Independence and Security Act (EISA) of 2007.

  17. In situ Analysis of Organic Matter in Martian Soil: Laboratory Measurements Under Martian Operating Conditions Supporting Treatment and Interpretation of SAM GC-MS Data

    NASA Astrophysics Data System (ADS)

    Millan, M.; Szopa, C.; Coll, P.; Buch, A.; Cabane, M.; Coscia, D.; Glavin, D. P.; Freissinet, C.

    2014-07-01

    This work presents laboratory measurements under martian operating conditions in comparison with the SAM GC-MS data provided by the Curiosity rover. Their treatment and interpretation supports the in situ analysis of organic matter on Mars.

  18. OB's high voltage laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1966-01-01

    The January issue of Hi-Tension News provides a detailed description of the advanced surge test facilities and procedures in daily operation at the OB High Voltage Laboratory in Barberton, Ohio. Technical competences achieved in this laboratory contribute to the essential factors of design confirmation to basic studies of ehv insulation systems, conductor and hardware performance, and optimum tower construction. Known throughout the industry for authenticity of its full scale, all weather outdoor testing, OB's High Voltage Laboratory is a full-fledged participant in the NEMA-sponsored program to make testing facilities available on a cooperative basis.

  19. Sonication standard laboratory module

    DOEpatents

    Beugelsdijk, Tony; Hollen, Robert M.; Erkkila, Tracy H.; Bronisz, Lawrence E.; Roybal, Jeffrey E.; Clark, Michael Leon

    1999-01-01

    A standard laboratory module for automatically producing a solution of cominants from a soil sample. A sonication tip agitates a solution containing the soil sample in a beaker while a stepper motor rotates the sample. An aspirator tube, connected to a vacuum, draws the upper layer of solution from the beaker through a filter and into another beaker. This beaker can thereafter be removed for analysis of the solution. The standard laboratory module encloses an embedded controller providing process control, status feedback information and maintenance procedures for the equipment and operations within the standard laboratory module.

  20. Environmental Laboratory Advisory Board

    EPA Pesticide Factsheets

    The Environmental Laboratory Advisory Board (ELAB) was established to provide consensus advice, information and recommendations on issues related to EPA measurement programs, and operation of the national accreditation program

  1. Autoclaving practice in microbiology laboratories: report of a survey. The Public Health Laboratory Service Subcommittee on laboratory autoclaves.

    PubMed Central

    1978-01-01

    The performance of autoclaves in 27 laboratories, operated in accordance with the normal routine of local practice, has been monitored using thermometric equipment. Sterilising performance was unsatisfactory on 10 of 62 occasions, and cooling was inadequate on 52 of 60 occasions. PMID:649767

  2. Site Environmental Report for Calendar Year 2004. DOE Operations at The Boeing Company Santa Susana Field Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Ning; Rutherford, Phil; Lee, Majelle

    2005-09-01

    This Annual Site Environmental Report (ASER) for 2004 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of Boeing’s Santa Susana Field Laboratory (SSFL). In the past, the Energy Technology Engineering Center (ETEC), a government-owned, company-operated test facility, was located in Area IV. The operations in Area IV included development, fabrication, and disassembly of nuclear reactors, reactor fuel, and other radioactive materials. Other activities in the area involved the operation of large-scale liquid metal facilities that were used for testing non-nuclear liquid metal fast breeder components. All nuclear work was terminated inmore » 1988; all subsequent radiological work has been directed toward decontamination and decommissioning (D&D) of the former nuclear facilities and their associated sites. Closure of the liquid metal test facilities began in 1996. Results of the radiological monitoring program for the calendar year 2004 continue to indicate that there are no significant releases of radioactive material from Area IV of SSFL. All potential exposure pathways are sampled and/or monitored, including air, soil, surface water, groundwater, direct radiation, transfer of property (land, structures, waste), and recycling.« less

  3. 7 CFR 58.442 - Laboratory and quality control tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.442 Section... Service 1 Operations and Operating Procedures § 58.442 Laboratory and quality control tests. (a) Chemical... Methods or by other methods giving equivalent results. (b) Weight or volume control. Representative...

  4. 7 CFR 58.442 - Laboratory and quality control tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Laboratory and quality control tests. 58.442 Section... Service 1 Operations and Operating Procedures § 58.442 Laboratory and quality control tests. (a) Chemical... Methods or by other methods giving equivalent results. (b) Weight or volume control. Representative...

  5. Field monitoring and evaluation of a residential gas-engine-driven heat pump: Volume 2, Heating season

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, J.D.

    1995-11-01

    The Federal Government is the largest single energy consumer in the United States; consumption approaches 1.5 quads/year of energy (1 quad = 10{sup 15} Btu) at a cost valued at nearly $10 billion annually. The US Department of Energy (DOE) Federal Energy Management Program (FEMP) supports efforts to reduce energy use and associated expenses in the Federal sector. One such effort, the New Technology Demonstration Program (NTDP), seeks to evaluate new energy-saving US technologies and secure their more timely adoption by the US Government. Pacific Northwest Laboratory (PNL) is one of four DOE national multiprogram laboratories that participate in themore » NTDP by providing technical expertise and equipment to evaluate new, energy-saving technologies being studied and evaluated under that program. This two-volume report describes a field evaluation that PNL conducted for DOE/FEMP and the US Department of Defense (DoD) Strategic Environmental Research and Development Program (SERDP) to examine the performance of a candidate energy-saving technology -- a gas-engine-driven heat pump. The unit was installed at a single residence at Fort Sam Houston, a US Army base in San Antonio, Texas, and the performance was monitored under the NTDP. Participating in this effort under a Cooperative Research and Development Agreement (CRADA) were York International, the heat pump manufacturer; Gas Research Institute (GRI), the technology developer; City Public Service of San Antonio, the local utility; American Gas Cooling Center (AGCC); Fort Sam Houston; and PNL.« less

  6. The Design and Operation of an Effective Math Laboratory.

    ERIC Educational Resources Information Center

    Brown, Donald E.

    A mathematics laboratory is discussed in terms of (1) administrative support, (2) personnel, (3) curriculum design, (4) flexibility in design and equipment, (5) professional counseling, and (6) motivational devices. The discussion focuses upon the remedial math lab at Alvin Community College, Alvin, Texas. The roles of instructors, lab…

  7. Implementing a laboratory automation system: experience of a large clinical laboratory.

    PubMed

    Lam, Choong Weng; Jacob, Edward

    2012-02-01

    Laboratories today face increasing pressure to automate their operations as they are challenged by a continuing increase in workload, need to reduce expenditure, and difficulties in recruitment of experienced technical staff. Was the implementation of a laboratory automation system (LAS) in the Clinical Biochemistry Laboratory at Singapore General Hospital successful? There is no simple answer, so the following topics comparing and contrasting pre- and post-LAS have been explored: turnaround time (TAT), laboratory errors, and staff satisfaction. The benefits and limitations of LAS from the laboratory experience were also reviewed. The mean TAT for both stat and routine samples decreased post-LAS (30% and 13.4%, respectively). In the 90th percentile TAT chart, a 29% reduction was seen in the processing of stat samples on the LAS. However, no significant difference in the 90th percentile TAT was observed with routine samples. It was surprising to note that laboratory errors increased post-LAS. Considerable effort was needed to overcome the initial difficulties associated with adjusting to a new system, new software, and new working procedures. Although some of the known advantages and limitations of LAS have been validated, the claimed benefits such as improvements in TAT, laboratory errors, and staff morale were not evident in the initial months.

  8. The Joint Committee for Traceability in Laboratory Medicine (JCTLM) - its history and operation.

    PubMed

    Jones, Graham R D; Jackson, Craig

    2016-01-30

    The Joint Committee for Traceability in Laboratory Medicine (JCTLM) was formed to bring together the sciences of metrology, laboratory medicine and laboratory quality management. The aim of this collaboration is to support worldwide comparability and equivalence of measurement results in clinical laboratories for the purpose of improving healthcare. The JCTLM has its origins in the activities of international metrology treaty organizations, professional societies and federations devoted to improving measurement quality in physical, chemical and medical sciences. The three founding organizations, the International Committee for Weights and Measures (CIPM), the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and the International Laboratory Accreditation Cooperation (ILAC) are the leaders of this activity. The main service of the JCTLM is a web-based database with a list of reference materials, reference methods and reference measurement services meeting appropriate international standards. This database allows manufacturers to select references for assay traceability and provides support for suppliers of these services. As of mid 2015 the database lists 295 reference materials for 162 analytes, 170 reference measurement procedures for 79 analytes and 130 reference measurement services for 39 analytes. There remains a need for the development and implementation of metrological traceability in many areas of laboratory medicine and the JCTLM will continue to promote these activities into the future. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 2. General Practices.

    PubMed

    Mazur, Steven; Holbrook, Michael R; Burdette, Tracey; Joselyn, Nicole; Barr, Jason; Pusl, Daniela; Bollinger, Laura; Coe, Linda; Jahrling, Peter B; Lackemeyer, Matthew G; Wada, Jiro; Kuhn, Jens H; Janosko, Krisztina

    2016-10-03

    Work in a biosafety level 4 (BSL-4) containment laboratory requires time and great attention to detail. The same work that is done in a BSL-2 laboratory with non-high-consequence pathogens will take significantly longer in a BSL-4 setting. This increased time requirement is due to a multitude of factors that are aimed at protecting the researcher from laboratory-acquired infections, the work environment from potential contamination and the local community from possible release of high-consequence pathogens. Inside the laboratory, movement is restricted due to air hoses attached to the mandatory full-body safety suits. In addition, disinfection of every item that is removed from Class II biosafety cabinets (BSCs) is required. Laboratory specialists must be trained in the practices of the BSL-4 laboratory and must show high proficiency in the skills they are performing. The focus of this article is to outline proper procedures and techniques to ensure laboratory biosafety and experimental accuracy using a standard viral plaque assay as an example procedure. In particular, proper techniques to work safely in a BSL-4 environment when performing an experiment will be visually emphasized. These techniques include: setting up a Class II BSC for experiments, proper cleaning of the Class II BSC when finished working, waste management and safe disposal of waste generated inside a BSL-4 laboratory, and the removal of inactivated samples from inside a BSL-4 laboratory to the BSL-2 laboratory.

  10. Concept for a commercial space station laboratory

    NASA Technical Reports Server (NTRS)

    Wood, P. W.; Stark, P. M.

    1984-01-01

    The concept of a privately owned and operated fee-for-service laboratory as an element of a civil manned space station, envisioned as the venture of a group of private investors and an experienced laboratory operator to be undertaken with the cooperation of NASA is discussed. This group would acquire, outfit, activate, and operate the labortory on a fee-for-service basis, providing laboratory services to commercial firms, universities, and government agencies, including NASA. This concept was developed to identify, stimulate, and assist potential commercial users of a manned space station. A number of the issues which would be related to the concept, including the terms under which NASA might consider permitting private ownership and operation of a major space station component, the policies with respect to international participation in the construction and use of the space station, the basis for charging users for services received from the space station, and the types of support that NASA might be willing to provide to assist private industry in carrying out such a venture are discussed.

  11. Chemistry in a Large, Multidisciplinary Laboratory.

    ERIC Educational Resources Information Center

    Lingren, Wesley E.; Hughson, Robert C.

    1982-01-01

    Describes a science facility built at Seattle Pacific University for approximately 70 percent of the capital cost of a conventional science building. The building serves seven disciplines on a regular basis. The operation of the multidisciplinary laboratory, special features, laboratory security, and student experience/reactions are highlighted.…

  12. 7 CFR 58.523 - Laboratory and quality control tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  13. 7 CFR 58.523 - Laboratory and quality control tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  14. 7 CFR 58.523 - Laboratory and quality control tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  15. 7 CFR 58.523 - Laboratory and quality control tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  16. 7 CFR 58.523 - Laboratory and quality control tests.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  17. Mini-percutaneous nephrolithotomy for stones in anomalous-kidneys: a prospective study.

    PubMed

    Khadgi, Sanjay; Shrestha, Babu; Ibrahim, Hamdy; Shrestha, Sunil; ElSheemy, Mohammed S; Al-Kandari, Ahmed M

    2017-08-01

    To evaluate safety and efficacy of minipercutaneous nephrolithotomy (Mini-PNL) in management of stones in different types of renal anomalies. Patients with stones ≥2 cm or SWL-resistant stones in anomalous-kidneys treated by Mini-PNL between March 2010 and September 2012 were included prospectively. Mini-PNL was done under regional anesthesia in prone position with fluoroscopic guidance through 18 Fr sheath using semirigid ureteroscope (8.5/11.5 Fr) and pneumatic lithotripter. All patients were followed-up for 2-3 years. Stone-free rate was defined as absence of residual fragments ≥2 mm. Student-T, Mann-Whitney, Chi square (χ 2 ), Fisher-exact, one way ANOVA or Kruskal-Wallis test were used for analysis. Mini-PNL was performed for 59 patients (20 horseshoe, 15 malrotated, 7 polycystic, 13 duplex and 4 ectopic pelvic-kidneys). Mean age was 40.18 ± 12.75 (14-78) years. Mean stone burden was 31.72 ± 21.43 (7.85-141.3) mm 2 . Two tracts were required in 7 (11.9 %) patients. Tubeless Mini-PNL with double-J insertion was performed in all patients except two. Operative time was 50.17 ± 18.73 (15-105) min. Hemoglobin loss was 0.44 ± 0.30 (0-1.4) g/dL. Complications were reported in 15 (25.4 %) patients. No pleural injury, sepsis, perinephric-collection or renal-pelvis perforation were reported. Stone-free rate was 89.8 % (converted to open-surgery in one patient, second-look PNL in two patients, auxiliary SWL in three patients). Stone-free rate improved to 98.3 % after retreatment and auxiliary SWL. Site of puncture was mostly upper calyceal in horseshoe-kidney (80 %), mid calyceal in polycystic-kidney (85.7 %) and lower calyceal in duplex-kidney (46.2 %). Punctures were also significantly infracostal in horseshoe-kidney (100 %) and supracostal in both duplex (53.8 %) and malrotated-kidneys (66.7 %). Mini-PNL is safe for management of stones in anomalous-kidney with SFR comparable to standard-PNL but with less complications.

  18. Undergraduate Laboratory Module on Skin Diffusion

    ERIC Educational Resources Information Center

    Norman, James J.; Andrews, Samantha N.; Prausnitz, Mark R.

    2011-01-01

    To introduce students to an application of chemical engineering directly related to human health, we developed an experiment for the unit operations laboratory at Georgia Tech examining diffusion across cadaver skin in the context of transdermal drug delivery. In this laboratory module, students prepare mouse skin samples, set up diffusion cells…

  19. Medical Service Clinical Laboratory Procedure--Hematology.

    ERIC Educational Resources Information Center

    Department of the Army, Washington, DC.

    Presented are laboratory studies focusing on blood cells and the complete scheme of blood coagulation. Formed is the basis for the following types of laboratory operations: (1) distinguishing the morphology of normal and abnormal blood cells; (2) measuring the concentrations or number of blood cells; (3) measuring concentration and detecting…

  20. Report on Operations of the Air Force Geophysics Laboratory Infrared Array Spectrometer

    DTIC Science & Technology

    1993-01-25

    AIR FORCE GEOPHYSICS LABORATORY INFRARED ARRAY... LABORATORY Directorate of Geophysics AIR FORCE MATERIEL COMMAND HANSCOM AIR FORCE BASE, MA 01731-3010 93-27655IEEE|EIIE1ENI This technical report has...ACKNOWLEDGMENT We are grateful to the Air Force Office of Scientific Research , especially Henry Radowski. for their financial corn- mitment to this project.

  1. Operational Amplifier Experiments for the Chemistry Laboratory.

    ERIC Educational Resources Information Center

    Braun, Robert D.

    1996-01-01

    Provides details of experiments that deal with the use of operational amplifiers and are part of a course in instrumental analysis. These experiments are performed after the completion of a set of electricity and electronics experiments. (DDR)

  2. Report: Review of Region 5 Laboratory Operations

    EPA Pesticide Factsheets

    Report #2000-P-3, Jan 1, 2000. In September 1998, the Region 5 Quality Assurance Core initiated a Management Systems Review of the CRL to determine whether the lab’s quality management system was operating as designed.

  3. [Outsourcing of clinical laboratory department].

    PubMed

    Murai, T

    2000-03-01

    Recently, to improve financial difficulties at various hospitals, outsourcing of the laboratory department is be coming more wide spread. At the department of clinical pathology of St. Luke's International Hospital, the system, so called, "Branch labo" which is one of the outsourcing laboratory conditions, was adopted in March 1999. In this reports. We described the decision procedure for accepting the situation and the circumstances of operation.

  4. Establishment of Biosafety Level-3 (BSL-3) laboratory: Important criteria to consider while designing, constructing, commissioning & operating the facility in Indian setting

    PubMed Central

    Mourya, Devendra T.; Yadav, Pragya D.; Majumdar, Triparna Dutta; Chauhan, Devendra S.; Katoch, Vishwa Mohan

    2014-01-01

    Since the enactment of Environmental Protection Act in 1989 and Department of Biotechnology (DBT) guidelines to deal with genetically modified organisms, India has embarked on establishing various levels of biosafety laboratories to deal with highly infectious and pathogenic organisms. Occurrence of outbreaks due to rapidly spreading respiratory and haemorrhagic fever causing viruses has caused an urgency to create a safe laboratory environment. This has thus become a mandate, not only to protect laboratory workers, but also to protect the environment and community. In India, technology and science are progressing rapidly. Several BSL-3 [=high containment] laboratories are in the planning or execution phase, to tackle biosafety issues involved in handling highly infectious disease agents required for basic research and diagnosis. In most of the developing countries, the awareness about biocontainment has increased but planning, designing, constructing and operating BSL-3 laboratories need regular updates about the design and construction of facilities and clear definition of risk groups and their handling which should be in harmony with the latest international practices. This article describes the major steps involved in the process of construction of a BSL-3 laboratory in Indian settings, from freezing the concept of proposal to operationalization phase. The key to success of this kind of project is strong institutional commitment to biosafety norms, adequate fund availability, careful planning and designing, hiring good construction agency, monitoring by experienced consultancy agency and involvement of scientific and engineering personnel with biocontainment experience in the process. PMID:25297350

  5. Establishment of Biosafety Level-3 (BSL-3) laboratory: important criteria to consider while designing, constructing, commissioning & operating the facility in Indian setting.

    PubMed

    Mourya, Devendra T; Yadav, Pragya D; Majumdar, Triparna Dutta; Chauhan, Devendra S; Katoch, Vishwa Mohan

    2014-08-01

    Since the enactment of Environmental Protection Act in 1989 and Department of Biotechnology (DBT) guidelines to deal with genetically modified organisms, India has embarked on establishing various levels of biosafety laboratories to deal with highly infectious and pathogenic organisms. Occurrence of outbreaks due to rapidly spreading respiratory and haemorrhagic fever causing viruses has caused an urgency to create a safe laboratory environment. This has thus become a mandate, not only to protect laboratory workers, but also to protect the environment and community. In India, technology and science are progressing rapidly. Several BSL-3 [=high containment] laboratories are in the planning or execution phase, to tackle biosafety issues involved in handling highly infectious disease agents required for basic research and diagnosis. In most of the developing countries, the awareness about biocontainment has increased but planning, designing, constructing and operating BSL-3 laboratories need regular updates about the design and construction of facilities and clear definition of risk groups and their handling which should be in harmony with the latest international practices. This article describes the major steps involved in the process of construction of a BSL-3 laboratory in Indian settings, from freezing the concept of proposal to operationalization phase. The key to success of this kind of project is strong institutional commitment to biosafety norms, adequate fund availability, careful planning and designing, hiring good construction agency, monitoring by experienced consultancy agency and involvement of scientific and engineering personnel with biocontainment experience in the process.

  6. Exploration Laboratory Analysis FY13

    NASA Technical Reports Server (NTRS)

    Krihak, Michael; Perusek, Gail P.; Fung, Paul P.; Shaw, Tianna, L.

    2013-01-01

    The Exploration Laboratory Analysis (ELA) project supports the Exploration Medical Capability (ExMC) risk, which is stated as the Risk of Inability to Adequately Treat an Ill or Injured Crew Member, and ExMC Gap 4.05: Lack of minimally invasive in-flight laboratory capabilities with limited consumables required for diagnosing identified Exploration Medical Conditions. To mitigate this risk, the availability of inflight laboratory analysis instrumentation has been identified as an essential capability in future exploration missions. Mission architecture poses constraints on equipment and procedures that will be available to treat evidence-based medical conditions according to the Space Medicine Exploration Medical Conditions List (SMEMCL), and to perform human research studies on the International Space Station (ISS) that are supported by the Human Health and Countermeasures (HHC) element. Since there are significant similarities in the research and medical operational requirements, ELA hardware development has emerged as a joint effort between ExMC and HHC. In 2012, four significant accomplishments were achieved towards the development of exploration laboratory analysis for medical diagnostics. These achievements included (i) the development of high priority analytes for research and medical operations, (ii) the development of Level 1 functional requirements and concept of operations documentation, (iii) the selection and head-to-head competition of in-flight laboratory analysis instrumentation, and (iv) the phase one completion of the Small Business Innovation Research (SBIR) projects under the topic Smart Phone Driven Blood-Based Diagnostics. To utilize resources efficiently, the associated documentation and advanced technologies were integrated into a single ELA plan that encompasses ExMC and HHC development efforts. The requirements and high priority analytes was used in the selection of the four in-flight laboratory analysis performers. Based upon the

  7. The Case for Laboratory Developed Procedures

    PubMed Central

    Sabatini, Linda M.; Tsongalis, Gregory J.; Caliendo, Angela M.; Olsen, Randall J.; Ashwood, Edward R.; Bale, Sherri; Benirschke, Robert; Carlow, Dean; Funke, Birgit H.; Grody, Wayne W.; Hayden, Randall T.; Hegde, Madhuri; Lyon, Elaine; Pessin, Melissa; Press, Richard D.; Thomson, Richard B.

    2017-01-01

    An explosion of knowledge and technology is revolutionizing medicine and patient care. Novel testing must be brought to the clinic with safety and accuracy, but also in a timely and cost-effective manner, so that patients can benefit and laboratories can offer testing consistent with current guidelines. Under the oversight provided by the Clinical Laboratory Improvement Amendments, laboratories have been able to develop and optimize laboratory procedures for use in-house. Quality improvement programs, interlaboratory comparisons, and the ability of laboratories to adjust assays as needed to improve results, utilize new sample types, or incorporate new mutations, information, or technologies are positive aspects of Clinical Laboratory Improvement Amendments oversight of laboratory-developed procedures. Laboratories have a long history of successful service to patients operating under Clinical Laboratory Improvement Amendments. A series of detailed clinical examples illustrating the quality and positive impact of laboratory-developed procedures on patient care is provided. These examples also demonstrate how Clinical Laboratory Improvement Amendments oversight ensures accurate, reliable, and reproducible testing in clinical laboratories. PMID:28815200

  8. Engineering Water Analysis Laboratory Activity.

    ERIC Educational Resources Information Center

    Schlenker, Richard M.

    The purposes of water treatment in a marine steam power plant are to prevent damage to boilers, steam-operated equipment, and steam and condensate lives, and to keep all equipment operating at the highest level of efficiency. This laboratory exercise is designed to provide students with experiences in making accurate boiler water tests and to…

  9. Air Force Cambridge Research Laboratories balloon operations

    NASA Technical Reports Server (NTRS)

    Danaher, T. J.

    1974-01-01

    The establishment and functions of the AFCRL balloon operations facility are discussed. The types of research work conducted by the facility are defined. The facilities which support the balloon programs are described. The free balloon and tethered balloon capabilities are analyzed.

  10. Lawrence Livermore National Laboratory Environmental Report 2012

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, Henry E.; Armstrong, Dave; Blake, Rick G.

    Lawrence Livermore National Laboratory (LLNL) is a premier research laboratory that is part of the National Nuclear Security Administration (NNSA) within the U.S. Department of Energy (DOE). As a national security laboratory, LLNL is responsible for ensuring that the nation’s nuclear weapons remain safe, secure, and reliable. The Laboratory also meets other pressing national security needs, including countering the proliferation of weapons of mass destruction and strengthening homeland security, and conducting major research in atmospheric, earth, and energy sciences; bioscience and biotechnology; and engineering, basic science, and advanced technology. The Laboratory is managed and operated by Lawrence Livermore National Security,more » LLC (LLNS), and serves as a scientific resource to the U.S. government and a partner to industry and academia. LLNL operations have the potential to release a variety of constituents into the environment via atmospheric, surface water, and groundwater pathways. Some of the constituents, such as particles from diesel engines, are common at many types of facilities while others, such as radionuclides, are unique to research facilities like LLNL. All releases are highly regulated and carefully monitored. LLNL strives to maintain a safe, secure and efficient operational environment for its employees and neighboring communities. Experts in environment, safety and health (ES&H) support all Laboratory activities. LLNL’s radiological control program ensures that radiological exposures and releases are reduced to as low as reasonably achievable to protect the health and safety of its employees, contractors, the public, and the environment. LLNL is committed to enhancing its environmental stewardship and managing the impacts its operations may have on the environment through a formal Environmental Management System. The Laboratory encourages the public to participate in matters related to the Laboratory’s environmental impact on the

  11. Lawrence Livermore National Laboratory Environmental Report 2013

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, H. E.; Bertoldo, N. A.; Blake, R. G.

    Lawrence Livermore National Laboratory (LLNL) is a premier research laboratory that is part of the National Nuclear Security Administration (NNSA) within the U.S. Department of Energy (DOE). As a national security laboratory, LLNL is responsible for ensuring that the nation’s nuclear weapons remain safe, secure, and reliable. The Laboratory also meets other pressing national security needs, including countering the proliferation of weapons of mass destruction and strengthening homeland security, and conducting major research in atmospheric, earth, and energy sciences; bioscience and biotechnology; and engineering, basic science, and advanced technology. The Laboratory is managed and operated by Lawrence Livermore National Security,more » LLC (LLNS), and serves as a scientific resource to the U.S. government and a partner to industry and academia. LLNL operations have the potential to release a variety of constituents into the environment via atmospheric, surface water, and groundwater pathways. Some of the constituents, such as particles from diesel engines, are common at many types of facilities while others, such as radionuclides, are unique to research facilities like LLNL. All releases are highly regulated and carefully monitored. LLNL strives to maintain a safe, secure and efficient operational environment for its employees and neighboring communities. Experts in environment, safety and health (ES&H) support all Laboratory activities. LLNL’s radiological control program ensures that radiological exposures and releases are reduced to as low as reasonably achievable to protect the health and safety of its employees, contractors, the public, and the environment. LLNL is committed to enhancing its environmental stewardship and managing the impacts its operations may have on the environment through a formal Environmental Management System. The Laboratory encourages the public to participate in matters related to the Laboratory’s environmental impact on the

  12. Nephrostomy tube-free versus nephrostomy tube for renal drainage after percutaneous nephrolithotomy: a systematic review and meta-analysis.

    PubMed

    Shen, Pengfei; Liu, Yong; Wang, Jia

    2012-01-01

    Historically, percutaneous nephrostomy drainage following percutaneous nephrolithotomy (PNL) has been considered the standard of care. More recently, however, an increasing number of centers are performing tubeless (with insertion of JJ ureteric stent) or totally tubeless (with no internal or external drainage) PNL with impressive outcome data. This systematic review is to compare the clinical therapeutic efficacy and safety of nephrostomy tube-free (NT-free) and standard PNL. We searched PubMed (1966 to April 2011), Embase (1966 to April 2011), and the Cochrane Library without language restriction. All randomized controlled trials that compared NT-free PNL (using a double-J stent) with standard PNL were enrolled in this review. The Cochrane Collaboration's RevMan5.0.2 software was used for statistical analysis. Nine studies involving 547 patients were included. Patients were divided into 4 groups: NT-free group, small tube group (8-9 Fr), middle tube group (16-18 Fr), and large tube group (20-24 Fr). Meta-analysis showed that: (1) with regard to hospital stay (h) and visual analog scale scores for postoperative pain on day 1, there was no significant difference between the NT-free group and the small tube group, but there were differences between the NT-free group versus the middle and large tube groups; (2) for puncture site urinary leakage, no significant difference was found between the NT-free group and the small and middle tube groups; (3) no significant difference was found with regard to transfusion, fever or infection, operative time between the NT-free group and the 3 tube groups. The clinical efficacy and safety of NT-free and small tube are similar in all measurements. Compared with the middle and large tubes, NT-free PNL could reduce hospital stay and postoperative analgesia requirement without increasing other complications. Copyright © 2012 S. Karger AG, Basel.

  13. Minimally invasive percutaneous nephrolithotomy: an effective treatment for kidney stones in infants under 1 year of age. A single-center experience.

    PubMed

    Dağgülli, Mansur; Sancaktutar, Ahmet Ali; Dede, Onur; Utanğaç, Mehmet Mazhar; Bodakçi, Mehmet Nuri; Penbegül, Necmettin; Hatipoğlu, Namık Kemal; Çakmakçı, Süleyman

    2015-11-01

    We aimed to present the outcomes of PNL surgery performed in infantile patients with small renal stones who were younger than 1 year of age. A single-center prospective trial was initiated and during the period between Jan 2013 and Jan 2015, PNL was applied to 20 renal units of 16 infants (6 girls and 10 boys), including 4 patients with bilateral kidney stones. PNL was performed in patients with renal stones larger than 2 cm, as well as stones resistant to SWL or renal stones that were undetectable during SWL. The mean age of the patients was 9.55 (5-12) months. Of the 20 renal units, 1 had complete staghorn stones, 3 had partial staghorn stones, 13 had renal pelvic stones, and 3 had lower pole stones. The mean stone size was 18.5 mm (range 12-36 mm). Mean operative time for PNL was 88 (25-135 min). Mean fluoroscopy time was estimated as 3.4 min. Mean hemoglobin loss was 0.72 g/L (0.2-3). The mean hospital stay was 4.1 days (2-8 days). On postoperative day 1, a complete stone-free state was achieved in 70% of renal units (14 of 20). At the end of the first postoperative week, the remaining two patients had insignificant residual fragments of 3 mm and were followed conservatively without any specific intervention. Thus, the total SFR was 80% (16 of 20) at discharge. In infants aged less than 1 year, minimal access tract dilation during PNL, the use of smaller caliber pediatric instruments, and the realization of this procedure by surgeons with adequate experience in adults carry utmost importance. In addition, special care should be taken to avoid hypothermia and radiation exposure during PNL.

  14. Integrated Circuits in the Introductory Electronics Laboratory

    ERIC Educational Resources Information Center

    English, Thomas C.; Lind, David A.

    1973-01-01

    Discusses the use of an integrated circuit operational amplifier in an introductory electronics laboratory course for undergraduate science majors. The advantages of this approach and the implications for scientific instrumentation are identified. Describes a number of experiments suitable for the undergraduate laboratory. (Author/DF)

  15. USGS Laboratory Review Program Ensures Analytical Quality

    USGS Publications Warehouse

    Erdmann, David E.

    1995-01-01

    The USGS operates a review program for laboratories that analyze samples for USGS environmental investigations. This program has been effective in providing QA feedback to laboratories while ensuring that analytical data are consistent, of satisfactory quality, and meet the data objectives of the investigation.

  16. A Multi-User Remote Academic Laboratory System

    ERIC Educational Resources Information Center

    Barrios, Arquimedes; Panche, Stifen; Duque, Mauricio; Grisales, Victor H.; Prieto, Flavio; Villa, Jose L.; Chevrel, Philippe; Canu, Michael

    2013-01-01

    This article describes the development, implementation and preliminary operation assessment of Multiuser Network Architecture to integrate a number of Remote Academic Laboratories for educational purposes on automatic control. Through the Internet, real processes or physical experiments conducted at the control engineering laboratories of four…

  17. District, state or regional veterinary diagnostic laboratories.

    PubMed

    Gosser, H S; Morehouse, L G

    1998-08-01

    The district, regional or state laboratory is the local laboratory to which veterinarian practitioners usually submit samples, and consequently these laboratories are usually the first to observe a suspected disease problem. In most countries, these laboratories are under the jurisdiction of the State or region in which they are located. In the United States of America (USA), most veterinary diagnostic laboratories are State-associated and operate under the aegis of either the State Department of Agriculture or a university. The national laboratory provides reference assistance to the State laboratories. In the USA, the national Laboratory (the National Veterinary Services Laboratories) acts as a consultant to confirm difficult diagnoses and administer performance tests for State-associated laboratories. District, state or regional laboratories need to share information regarding technological advances in diagnostic procedures. This need was met in the USA by the formation of the American Association of Veterinary Laboratory Diagnosticians (AAVLD) in the late 1950s. Another requirement of district, state or regional diagnostic laboratories is a method to confirm quality assurance, which was fulfilled in the USA by an accreditation programme established through the AAVLD. The Accreditation Committee evaluates laboratories (on request) in terms of organisation, personnel, physical facilities and equipment, records, finance and budget. Those laboratories which meet the standards as established in the 'Essential Requirements for Accreditation' are given accreditation status, which indicates that they have the expertise and facilities to perform tests on food-producing animals for shipment in national or international commerce and on companion, laboratory or zoo animals. While confidentiality of test records is most important, it is becoming necessary to release certain types of animal disease test information if a country is to participate in the exportation of animals

  18. Hanford Laboratories monthly activities report, August 1963

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1963-09-16

    This is the monthly report for the Hanford Laboratories Operation, August 1963. Metallurgy, reactor fuels, chemistry, dosimetry, separation processes, reactor technology, financial activities, visits, biology operation, physics and instrumentation research, and employee relations are discussed.

  19. Inverter testing at Sandia National Laboratories

    NASA Astrophysics Data System (ADS)

    Ginn, Jerry W.; Bonn, Russell H.; Sittler, Greg

    1997-02-01

    Inverters are key building blocks of photovoltaic (PV) systems that produce ac power. The balance of systems (BOS) portion of a PV system can account for up to 50% of the system cost, and its reliable operation is essential for a successful PV system. As part of its BOS program, Sandia National Laboratories (SNL) maintains a laboratory wherein accurate electrical measurements of power systems can be made under a variety of conditions. This paper outlines the work that is done in that laboratory.

  20. Issues for laboratory outreach programs.

    PubMed

    1994-01-01

    As we saw in the last "As We See It," many hospitals have begun outreach programs. We explored why outreach programs are established, the steps needed to develop a program, and the way to establish the proper business culture in a hospital laboratory for running a successful program. In this issue we identify the new skills laboratory managers need to be outreach managers, show how some programs maintain a competitive advantage, and explain some of the effects health-care reform will have on outreach services, as we ask: What are the requirements and issues involved in operating a successful laboratory outreach program?

  1. Microwave remote sensing laboratory design

    NASA Technical Reports Server (NTRS)

    Friedman, E.

    1979-01-01

    Application of active and passive microwave remote sensing to the study of ocean pollution is discussed. Previous research efforts, both in the field and in the laboratory were surveyed to derive guidance for the design of a laboratory program of research. The essential issues include: choice of radar or radiometry as the observational technique; choice of laboratory or field as the research site; choice of operating frequency; tank sizes and material; techniques for wave generation and appropriate wavelength spectrum; methods for controlling and disposing of pollutants used in the research; and pollutants other than oil which could or should be studied.

  2. Implementation of Good Clinical Laboratory Practice (GCLP) guidelines within the External Quality Assurance Program Oversight Laboratory (EQAPOL).

    PubMed

    Todd, Christopher A; Sanchez, Ana M; Garcia, Ambrosia; Denny, Thomas N; Sarzotti-Kelsoe, Marcella

    2014-07-01

    The EQAPOL contract was awarded to Duke University to develop and manage global proficiency testing programs for flow cytometry-, ELISpot-, and Luminex bead-based assays (cytokine analytes), as well as create a genetically diverse panel of HIV-1 viral cultures to be made available to National Institutes of Health (NIH) researchers. As a part of this contract, EQAPOL was required to operate under Good Clinical Laboratory Practices (GCLP) that are traditionally used for laboratories conducting endpoint assays for human clinical trials. EQAPOL adapted these guidelines to the management of proficiency testing programs while simultaneously incorporating aspects of ISO/IEC 17043 which are specifically designed for external proficiency management. Over the first two years of the contract, the EQAPOL Oversight Laboratories received training, developed standard operating procedures and quality management practices, implemented strict quality control procedures for equipment, reagents, and documentation, and received audits from the EQAPOL Central Quality Assurance Unit. GCLP programs, such as EQAPOL, strengthen a laboratory's ability to perform critical assays and provide quality assessments of future potential vaccines. © 2013.

  3. Avian community composition in response to high explosive testing operations at Los Alamos National Laboratory in Northern New Mexico

    DOE PAGES

    Keller, David C.; Fresquez, Philip R.; Hansen, Leslie A.; ...

    2015-12-28

    Breeding bird abundance, species richness, evenness, diversity, composition, productivity, and survivorship were determined near a high-explosive detonation site at Los Alamos National Laboratory, New Mexico, USA, during pre-operation (1997-1999) and operation (2000-2014) periods. The operation periods consisted of detonations (<23 kg in yield and <3 per breeding season) in open air (2000-2002), within foam containment (2003-2006) and within steel vessel containment (2007-2014) systems; the latter two were employed to reduce noise and dispersal of high-explosives residues. A total of 2952 bird captures, representing 80 species, was recorded during 18 years of mist net operations using the Monitoring Avian Productivity andmore » Survivorship protocol. Individuals captured were identified to species, aged, sexed, and banded during May through August of each year. There were no significant differences (p > 0.05) in mean avian abundance and species evenness in any of the operation periods as compared with the pre-operation period. Species richness and diversity were significantly higher (p < 0.05) during the vessel containment period (2007-2014) than the pre-operation period. The time period of this study coincided with a wildfire (2000), a bark beetle infestation (2002), and two periods of drought (Nov 1999-Mar 2004 and Dec 2005-Dec 2014) that affected the study area. Furthermore, analysis of aerial photos determined that the average percent canopy cover of mature ponderosa pines (Pinus ponderosa) within 100 feet of mist net sites declined from 12% to 3% between 1991 and 2014 and the percent cover of shrubs slightly increased.« less

  4. Site Environmental Report for Calendar Year 2011. DOE Operations at The Boeing Company Santa Susana Field Laboratory, Area IV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Ning; Rutherford, Phil; Dassler, David

    2012-09-01

    This Annual Site Environmental Report (ASER) for 2011 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of Boeing’s Santa Susana Field Laboratory (SSFL). The Energy Technology Engineering Center (ETEC), a government-owned, company-operated test facility, was located in Area IV. The operations in Area IV included development, fabrication, operation and disassembly of nuclear reactors, reactor fuel, and other radioactive materials. Other activities in the area involved the operation of large-scale liquid metal facilities that were used for testing non-nuclear liquid metal fast breeder reactor components. All nuclear work was terminated in 1988,more » and all subsequent radiological work has been directed toward environmental restoration and decontamination and decommissioning (D&D) of the former nuclear facilities and their associated sites. Liquid metal research and development ended in 2002. Since May 2007, the D&D operations in Area IV have been suspended by the DOE, but the environmental monitoring and characterization programs have continued. Results of the radiological monitoring program for the calendar year 2011 continue to indicate that there are no significant releases of radioactive material from Area IV of SSFL. All potential exposure pathways are sampled and/or monitored, including air, soil, surface water, groundwater, direct radiation, transfer of property (land, structures, waste), and recycling.« less

  5. Site Environmental Report For Calendar Year 2012. DOE Operations at The Boeing Company Santa Susana Field Laboratory, Area IV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Ning; Rutherford, Phil; Dassler, David

    2013-09-01

    This Annual Site Environmental Report (ASER) for 2012 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of Boeing’s Santa Susana Field Laboratory (SSFL). The Energy Technology Engineering Center (ETEC), a government-owned, company-operated test facility, was located in Area IV. The operations in Area IV included development, fabrication, operation and disassembly of nuclear reactors, reactor fuel, and other radioactive materials. Other activities in the area involved the operation of large-scale liquid metal facilities that were used for testing non-nuclear liquid metal fast breeder reactor components. All nuclear work was terminated in 1988,more » and all subsequent radiological work has been directed toward environmental restoration and decontamination and decommissioning (D&D) of the former nuclear facilities and their associated sites. Liquid metal research and development ended in 2002. Since May 2007, the D&D operations in Area IV have been suspended by the DOE, but the environmental monitoring and characterization programs have continued. Results of the radiological monitoring program for the calendar year 2012 continue to indicate that there are no significant releases of radioactive material from Area IV of SSFL. All potential exposure pathways are sampled and/or monitored, including air, soil, surface water, groundwater, direct radiation, transfer of property (land, structures, waste), and recycling.« less

  6. [ISO 15189 accreditation in clinical microbiology laboratory: general concepts and the status in our laboratory].

    PubMed

    Akyar, Işin

    2009-10-01

    One important trend in the laboratory profession and quality management is the global convergence of laboratory operations. The goal of an accredited medical laboratory is to continue "offering useful laboratory service for diagnosis and treatment of the patients and also aid to the health of the nation". An accredited clinical laboratory is managed by a quality control system, it is competent technically and the laboratory service meets the needs of all its patients and physicians by taking the responsibility of all the medical tests and therapies. For this purpose, ISO 15189 international standard has been prepared by 2003. ISO 15189 standard is originated from the arrangement of ISO 17025 and ISO 9001:2000 standards. Many countries such as England, Germany, France, Canada and Australia have preferred ISO 15189 as their own laboratory accreditation programme, meeting all the requirements of their medical laboratories. The accreditation performance of a clinical microbiology laboratory is mainly based on five essential points; preanalytical, analytical, postanalytical, quality control programmes (internal, external, interlaboratory) and audits (internal, external). In this review article, general concepts on ISO 15189 accreditation standards for the clinical microbiology laboratories have been summarized and the status of a private laboratory (Acibadem LabMed, Istanbul) in Turkey has been discussed.

  7. An Overview of Current Capabilities and Research Activities in the Airspace Operations Laboratory at NASA Ames Research Center

    NASA Technical Reports Server (NTRS)

    Prevot, Thomas; Smith, Nancy M.; Palmer, Everett; Callantine, Todd; Lee, Paul; Mercer, Joey; Homola, Jeff; Martin, Lynne; Brasil, Connie; Cabrall, Christopher

    2014-01-01

    The Airspace Operations Laboratory at NASA Ames conducts research to provide a better understanding of roles, responsibilities, and requirements for human operators and automation in future air traffic management (ATM) systems. The research encompasses developing, evaluating, and integrating operational concepts and technologies for near-, mid-, and far-term air traffic operations. Current research threads include efficient arrival operations, function allocation in separation assurance and efficient airspace and trajectory management. The AOL has developed powerful air traffic simulation capabilities, most notably the Multi Aircraft Control System (MACS) that is used for many air traffic control simulations at NASA and its partners in government, academia and industry. Several additional NASA technologies have been integrated with the AOL's primary simulation capabilities where appropriate. Using this environment, large and small-scale system-level evaluations can be conducted to help make near-term improvements and transition NASA technologies to the FAA, such as the technologies developed under NASA's Air Traffic Management Demonstration-1 (ATD-1). The AOL's rapid prototyping and flexible simulation capabilities have proven a highly effective environment to progress the initiation of trajectory-based operations and support the mid-term implementation of NextGen. Fundamental questions about accuracy requirements have been investigated as well as realworld problems on how to improve operations in some of the most complex airspaces in the US. This includes using advanced trajectory-based operations and prototype tools for coordinating arrivals to converging runways at Newark airport and coordinating departures and arrivals in the San Francisco and the New York metro areas. Looking beyond NextGen, the AOL has started exploring hybrid human/automation control strategies as well as highly autonomous operations in the air traffic control domain. Initial results

  8. 41 CFR 101-25.109 - Laboratory and research equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... equipped and/or used for scientific research, testing, or analysis, except clinical laboratories operating... 41 Public Contracts and Property Management 2 2011-07-01 2007-07-01 true Laboratory and research...-General Policies § 101-25.109 Laboratory and research equipment. (a) This section prescribes controls for...

  9. The WHO/PEPFAR collaboration to prepare an operations manual for HIV prevention, care, and treatment at primary health centers in high-prevalence, resource-constrained settings: defining laboratory services.

    PubMed

    Spira, Thomas; Lindegren, Mary Lou; Ferris, Robert; Habiyambere, Vincent; Ellerbrock, Tedd

    2009-06-01

    The expansion of HIV/AIDS care and treatment in resource-constrained countries, especially in sub-Saharan Africa, has generally developed in a top-down manner. Further expansion will involve primary health centers where human and other resources are limited. This article describes the World Health Organization/President's Emergency Plan for AIDS Relief collaboration formed to help scale up HIV services in primary health centers in high-prevalence, resource-constrained settings. It reviews the contents of the Operations Manual developed, with emphasis on the Laboratory Services chapter, which discusses essential laboratory services, both at the center and the district hospital level, laboratory safety, laboratory testing, specimen transport, how to set up a laboratory, human resources, equipment maintenance, training materials, and references. The chapter provides specific information on essential tests and generic job aids for them. It also includes annexes containing a list of laboratory supplies for the health center and sample forms.

  10. Laboratory automation: trajectory, technology, and tactics.

    PubMed

    Markin, R S; Whalen, S A

    2000-05-01

    Laboratory automation is in its infancy, following a path parallel to the development of laboratory information systems in the late 1970s and early 1980s. Changes on the horizon in healthcare and clinical laboratory service that affect the delivery of laboratory results include the increasing age of the population in North America, the implementation of the Balanced Budget Act (1997), and the creation of disease management companies. Major technology drivers include outcomes optimization and phenotypically targeted drugs. Constant cost pressures in the clinical laboratory have forced diagnostic manufacturers into less than optimal profitability states. Laboratory automation can be a tool for the improvement of laboratory services and may decrease costs. The key to improvement of laboratory services is implementation of the correct automation technology. The design of this technology should be driven by required functionality. Automation design issues should be centered on the understanding of the laboratory and its relationship to healthcare delivery and the business and operational processes in the clinical laboratory. Automation design philosophy has evolved from a hardware-based approach to a software-based approach. Process control software to support repeat testing, reflex testing, and transportation management, and overall computer-integrated manufacturing approaches to laboratory automation implementation are rapidly expanding areas. It is clear that hardware and software are functionally interdependent and that the interface between the laboratory automation system and the laboratory information system is a key component. The cost-effectiveness of automation solutions suggested by vendors, however, has been difficult to evaluate because the number of automation installations are few and the precision with which operational data have been collected to determine payback is suboptimal. The trend in automation has moved from total laboratory automation to a

  11. 76 FR 78814 - National Voluntary Laboratory Accreditation Program; Operating Procedures

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-20

    ... requirements for accreditation bodies accrediting conformity assessment bodies. The change will allow NVLAP... the human environment. Therefore, an environmental assessment or Environmental Impact Statement is not..., Laboratories, Measurement standards, Testing. For the reasons set forth in the preamble, title 15 of the Code...

  12. Exponential Formulae and Effective Operations

    NASA Technical Reports Server (NTRS)

    Mielnik, Bogdan; Fernandez, David J. C.

    1996-01-01

    One of standard methods to predict the phenomena of squeezing consists in splitting the unitary evolution operator into the product of simpler operations. The technique, while mathematically general, is not so simple in applications and leaves some pragmatic problems open. We report an extended class of exponential formulae, which yield a quicker insight into the laboratory details for a class of squeezing operations, and moreover, can be alternatively used to programme different type of operations, as: (1) the free evolution inversion; and (2) the soft simulations of the sharp kicks (so that all abstract results involving the kicks of the oscillator potential, become realistic laboratory prescriptions).

  13. Hanford Laboratories monthly activities report, February 1964

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1964-03-16

    This is the monthly report for the Hanford Laboratories Operation, February, 1964. Reactor fuels, chemistry, dosimetry, separation process, reactor technology financial activities, biology operation, physics and instrumentation research, employee relations, applied mathematics, programming, and radiation protection are discussed.

  14. Percutaneous nephrolithotomy with one-shot dilation method: Is it safe in patients who had open surgery before?

    PubMed

    Süelözgen, Tufan; Isoglu, Cemal Selcuk; Turk, Hakan; Yoldas, Mehmet; Karabicak, Mustafa; Ergani, Batuhan; Boyacioglu, Hayal; Ilbey, Yusuf Ozlem; Zorlu, Ferruh

    2016-01-01

    This study aimed to evaluate whether one-shot dilatation technique is as safe in patients with a history of open-stone surgery as it is in patients without previous open-stone surgery. Between January 2007 and February 2015, 82 patients who underwent percutaneous nephrolithotomy (PNL) surgery with one-shot dilation technique who previously had open-stone surgery were retrospectively reviewed and evaluated (Group 1). Another 82 patients were selected randomly among patients who had PNL with one-shot dilation technique, but with no history of open renal surgery (Group 2). Age, gender, type of kidney stone, duration of surgery, radiation exposure time, and whether or not there was any bleeding requiring perioperative and postoperative transfusion were noted for each patient. The stone-free rates, operation and fluoroscopy time, and peroperative and postoperative complication rates were similar in both groups (p>0.05). Our experience indicated that PNL with one-shot dilation technique is a reliable method in patients with a history of open-stone surgery.

  15. Site Environmental Report for Calendar Year 2008. DOE Operations at The Boeing Company Santa Susana Field Laboratory, Area IV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Ning; Rutherford, Phil; Amar, Ravnesh

    2009-09-01

    This Annual Site Environmental Report (ASER) for 2008 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of Boeing’s Santa Susana Field Laboratory (SSFL). The Energy Technology Engineering Center (ETEC), a government-owned, company-operated test facility, was located in Area IV. The operations in Area IV included development, fabrication, and disassembly of nuclear reactors, reactor fuel, and other radioactive materials. Other activities in the area involved the operation of large-scale liquid metal facilities that were used for testing non-nuclear liquid metal fast breeder reactor components. All nuclear work was terminated in 1988; allmore » subsequent radiological work has been directed toward decontamination and decommissioning (D&D) of the former nuclear facilities and their associated sites. In May 2007, the D&D operations in Area IV were suspended by the DOE. The environmental monitoring programs were continued throughout the year. Results of the radiological monitoring program for the calendar year 2008 continue to indicate that there are no significant releases of radioactive material from Area IV of SSFL. All potential exposure pathways are sampled and/or monitored, including air, soil, surface water, groundwater, direct radiation, transfer of property (land, structures, waste), and recycling.« less

  16. 49 CFR 199.107 - Drug testing laboratory.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Drug testing laboratory. 199.107 Section 199.107... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.107 Drug testing laboratory. (a) Each operator shall use for the drug testing required by this...

  17. 49 CFR 199.107 - Drug testing laboratory.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Drug testing laboratory. 199.107 Section 199.107... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.107 Drug testing laboratory. (a) Each operator shall use for the drug testing required by this...

  18. 49 CFR 199.107 - Drug testing laboratory.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Drug testing laboratory. 199.107 Section 199.107... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.107 Drug testing laboratory. (a) Each operator shall use for the drug testing required by this...

  19. 49 CFR 199.107 - Drug testing laboratory.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Drug testing laboratory. 199.107 Section 199.107... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.107 Drug testing laboratory. (a) Each operator shall use for the drug testing required by this...

  20. 49 CFR 199.107 - Drug testing laboratory.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Drug testing laboratory. 199.107 Section 199.107... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.107 Drug testing laboratory. (a) Each operator shall use for the drug testing required by this...

  1. Automation in the clinical microbiology laboratory.

    PubMed

    Novak, Susan M; Marlowe, Elizabeth M

    2013-09-01

    Imagine a clinical microbiology laboratory where a patient's specimens are placed on a conveyor belt and sent on an automation line for processing and plating. Technologists need only log onto a computer to visualize the images of a culture and send to a mass spectrometer for identification. Once a pathogen is identified, the system knows to send the colony for susceptibility testing. This is the future of the clinical microbiology laboratory. This article outlines the operational and staffing challenges facing clinical microbiology laboratories and the evolution of automation that is shaping the way laboratory medicine will be practiced in the future. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. [Solitary stones of the lower renal calyx: how to treat?

    PubMed

    Martov, A G; Ergakov, D V; Andronov, A S; Dutov, S V; Takhaev, R A; Kil'chukov, Z I; Moskalenko, S A

    2017-06-01

    The choice of treatment for the stones of the lower renal calyx is one of the challenging issues of modern urology. The aim of this retrospective and prospective study was to investigate the clinical effectiveness and safety of 3 modern minimally invasive techniques for treating renal stones: percutaneous (PNL) and transurethral (TNL) nephrolithotripsy and extracorporeal shock wave lithotripsy (ESWL) in patients with solitary lower calyx stones sized from 10 to 15 mm. The study included 136 patients with symptomatic stones of the lower calyces, who underwent ESWL, PNL and TNL from November 2010 to the present day. The criteria for inclusion in the study were: the presence of a solitary stone of the lower calyx, the stone size of 10 mm to 15 mm, the performance of the classical (standard) PNL in the prone position (puncture access 28-30 Fr) and the follow-up examination at 3 months after the operation. Forty-six patients underwent ESWL, 49 - PNL, and 41 - TNL. Postoperative follow-up was done at 3 months and included a plain radiography, ultrasound and non-contrast-enhanced computed tomography. The stone free rate (SFR) was used as a criterion for the effectiveness of the intervention, where the stone size of 3 mm was taken as the upper limit for the possible presence of fragments. Besides, the rate of repeat interventions, complications and subjective assessment of patients treatment satisfaction (0 to 10) by using visual analogue scale (VAS) were investigated. The effectiveness analysis of the three methods for treating the lower calyx stones sized 10-15 mm showed that PNL was no more effective than TNL (SFR 95.9% and 85.4%, respectively), but both methods were significantly more effective than ESWL (SFR 69.5%). 29.3% of patients who underwent TNL required repeat interventions (TNL or ESWL), while among those treated with ESWL, 45.6% required repeat ESWL sessions. PNL resulted in stone clearance in one stage. Postoperative inflammatory complications were most

  3. SWEIS annual review - CY2002 : a comparison of CY2002 operations to projections included in the site-wide environmental impact statement for continued operation of Sandia National Laboratories/New Mexico.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bayliss, Linda Sue; White, Brenda Bailey; Guerrero, Joseph Vincent

    2003-10-01

    The SNL/NM CY2002 SWEIS Annual Review discusses changes in facilities and facility operations that have occurred in selected and notable facilities since source data were collected for the SNL/NM SWEIS (DOE/EIS-0281). The following information is presented: {sm_bullet} An updated overview of SNL/NM selected and notable facilities and infrastructure capabilities. {sm_bullet} An overview of SNL/NM environment, safety, and health programs, including summaries of the purpose, operations, activities, hazards, and hazard controls at relevant facilities and risk management methods for SNL/NM. {sm_bullet} Updated base year activities data, together with related inventories, material consumption, emissions, waste, and resource consumption. {sm_bullet} Appendices summarizing activitiesmore » and related hazards at SNL/NM individual special, general, and highbay laboratories, and chemical purchases.« less

  4. Good laboratory practices guarantee biosafety in the Sierra Leone-China friendship biosafety laboratory.

    PubMed

    Wang, Qin; Zhou, Wei-Min; Zhang, Yong; Wang, Huan-Yu; Du, Hai-Jun; Nie, Kai; Song, Jing-Dong; Xiao, Kang; Lei, Wen-Wen; Guo, Jian-Qiang; Wei, He-Jiang; Cai, Kun; Wang, Yan-Hai; Wu, Jiang; Kamara, Gerard; Kamara, Idrissa; Wei, Qiang; Liang, Mi-Fang; Wu, Gui-Zhen; Dong, Xiao-Ping

    2016-06-23

    The outbreak of Ebola virus disease (EVD) in West Africa between 2014 and 2015 was the largest EDV epidemic since the identification of Ebola virus (EBOV) in 1976, and the countries most strongly affected were Sierra Leone, Guinea, and Liberia. The Sierra Leone-China Friendship Biological Safety Laboratory (SLE-CHN Biosafety Lab), a fixed Biosafety Level 3 laboratory in the capital city of Sierra Leone, was established by the Chinese government and has been active in EBOV detection since 11 March 2015. Complete management and program documents were created for the SLE-CHN Biosafety Lab, and it was divided into four zones (the green, yellow, brown, and red zones) based on the risk assessment. Different types of safe and appropriate personnel protection equipment (PPE) are used in different zones of the laboratory, and it fully meets the Biosafety Level 3 laboratory standards of the World Health Organization. Good preparedness, comprehensive risk assessment and operation documents, appropriate PPE, effective monitoring and intensive training, together with well-designed and reasonable laboratory sectioning are essential for guaranteeing biosafety.

  5. Research on the Error Characteristics of a 110 kV Optical Voltage Transformer under Three Conditions: In the Laboratory, Off-Line in the Field and During On-Line Operation

    PubMed Central

    Xiao, Xia; Hu, Haoliang; Xu, Yan; Lei, Min; Xiong, Qianzhu

    2016-01-01

    Optical voltage transformers (OVTs) have been applied in power systems. When performing accuracy performance tests of OVTs large differences exist between the electromagnetic environment and the temperature variation in the laboratory and on-site. Therefore, OVTs may display different error characteristics under different conditions. In this paper, OVT prototypes with typical structures were selected to be tested for the error characteristics with the same testing equipment and testing method. The basic accuracy, the additional error caused by temperature and the adjacent phase in the laboratory, the accuracy in the field off-line, and the real-time monitoring error during on-line operation were tested. The error characteristics under the three conditions—laboratory, in the field off-line and during on-site operation—were compared and analyzed. The results showed that the effect of the transportation process, electromagnetic environment and the adjacent phase on the accuracy of OVTs could be ignored for level 0.2, but the error characteristics of OVTs are dependent on the environmental temperature and are sensitive to the temperature gradient. The temperature characteristics during on-line operation were significantly superior to those observed in the laboratory. PMID:27537895

  6. The laboratory efficiencies initiative: partnership for building a sustainable national public health laboratory system.

    PubMed

    Ridderhof, John C; Moulton, Anthony D; Ned, Renée M; Nicholson, Janet K A; Chu, May C; Becker, Scott J; Blank, Eric C; Breckenridge, Karen J; Waddell, Victor; Brokopp, Charles

    2013-01-01

    Beginning in early 2011, the Centers for Disease Control and Prevention and the Association of Public Health Laboratories launched the Laboratory Efficiencies Initiative (LEI) to help public health laboratories (PHLs) and the nation's entire PHL system achieve and maintain sustainability to continue to conduct vital services in the face of unprecedented financial and other pressures. The LEI focuses on stimulating substantial gains in laboratories' operating efficiency and cost efficiency through the adoption of proven and promising management practices. In its first year, the LEI generated a strategic plan and a number of resources that PHL directors can use toward achieving LEI goals. Additionally, the first year saw the formation of a dynamic community of practitioners committed to implementing the LEI strategic plan in coordination with state and local public health executives, program officials, foundations, and other key partners.

  7. The Laboratory Efficiencies Initiative: Partnership for Building a Sustainable National Public Health Laboratory System

    PubMed Central

    Moulton, Anthony D.; Ned, Renée M.; Nicholson, Janet K.A.; Chu, May C.; Becker, Scott J.; Blank, Eric C.; Breckenridge, Karen J.; Waddell, Victor; Brokopp, Charles

    2013-01-01

    Beginning in early 2011, the Centers for Disease Control and Prevention and the Association of Public Health Laboratories launched the Laboratory Efficiencies Initiative (LEI) to help public health laboratories (PHLs) and the nation's entire PHL system achieve and maintain sustainability to continue to conduct vital services in the face of unprecedented financial and other pressures. The LEI focuses on stimulating substantial gains in laboratories' operating efficiency and cost efficiency through the adoption of proven and promising management practices. In its first year, the LEI generated a strategic plan and a number of resources that PHL directors can use toward achieving LEI goals. Additionally, the first year saw the formation of a dynamic community of practitioners committed to implementing the LEI strategic plan in coordination with state and local public health executives, program officials, foundations, and other key partners. PMID:23997300

  8. Laboratory Workhorse: The Analytical Balance.

    ERIC Educational Resources Information Center

    Clark, Douglas W.

    1979-01-01

    This report explains the importance of various analytical balances in the water or wastewater laboratory. Stressed is the proper procedure for utilizing the equipment as well as the mechanics involved in its operation. (CS)

  9. Idaho National Engineering Laboratory Waste Management Operations Roadmap Document

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bullock, M.

    1992-04-01

    At the direction of the Department of Energy-Headquarters (DOE-HQ), the DOE Idaho Field Office (DOE-ID) is developing roadmaps for Environmental Restoration and Waste Management (ER&WM) activities at Idaho National Engineering Laboratory (INEL). DOE-ID has convened a select group of contractor personnel from EG&G Idaho, Inc. to assist DOE-ID personnel with the roadmapping project. This document is a report on the initial stages of the first phase of the INEL`s roadmapping efforts.

  10. [Analysis of development, safety and efficacy of percutaneous nephrolithotomy for management of upper urinary tract calculi in pediatric patients].

    PubMed

    Yu, L P; Xu, T

    2017-08-18

    To evaluate the development, safety and efficacy of percutaneous nephrolithotomy(PNL) for management of upper urinary tract calculi in pediatric patients. In the study, 77 pediatric patients undergoing 87 PNLs through mini or standard tract for upper urinary tract calculi between January 2005 and December 2016 in Peking University People's hospital were reviewed, including 69 renal calculi, 6 upper ureteral calculi, 12 renal and upper ureteral calculi, 35 single calculi, 43 multiple calculi and 9 staghorn calculi. The development and efficacy of PNL in pediatric patients were studied by analyzing the characteristics and clinical indexes, and by reviewing the associated literature. The Clavien classification system was used to evaluate the complications after PNL. A total of 87 PNLs were performed in 77 pediatric patients. Eighty-one upper urinary tract calculi were managed through a single tract(93.1%), 5 pediatric patients were managed through 2 tracts(5.7%), and 1 pediatric patient was managed through 3 tracts(1.2%). The mean operating time was (77.0±29.8) min. The stone-free rate after one session was 100% for single calculi and 71.2% for multiple or staghorn calculi, 5(5.8%) children underwent auxiliary procedure to remove the residual calculi and the final stone-free rate of PNL was 88.5%. One of the main complications of pediatric PNL was fever. Sixteen (18.4%) had moderate fever(38-39 °C), 5 (5.7%) had high fever (39-40 °C) and there were no severe complications of infection, such as sepsis or septic shock. The mean hemoglobin loss was (10.3±16.1) g/L and the serum creatinine rise was (7.0±13.3) μmol/L. One(1.2%) pediatric patient suffered ureteroscopic lithotripsy because of the obstruction by the residual stone in ureter. No injury of organs or retroperitoneal urinary extravasation occurred. General assessment of the complications showed Clavien grade I complications in 14 (16.1%) pediatric patients, grade II in 7(8.0%) children and grade III in 1

  11. Overview of the NASA space radiation laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    La Tessa, Chiara; Sivertz, Michael; Chiang, I-Hung

    The NASA Space Radiation Laboratory (NSRL) is a multidisciplinary center for space radiation research funded by NASA and located at the Brookhaven National Laboratory (BNL), Upton NY. Operational since 2003, the scope of NSRL is to provide ion beams in support of the NASA Humans in Space program in radiobiology, physics and engineering to measure the risk and ameliorate the effect of radiation in space. Recently, it has also been recognized as the only facility in the U.S. currently capable of contributing to heavy ion radiotherapy research. Finally, this work contains a general overview of NSRL structure, capabilities and operation.

  12. Overview of the NASA space radiation laboratory

    DOE PAGES

    La Tessa, Chiara; Sivertz, Michael; Chiang, I-Hung; ...

    2016-11-11

    The NASA Space Radiation Laboratory (NSRL) is a multidisciplinary center for space radiation research funded by NASA and located at the Brookhaven National Laboratory (BNL), Upton NY. Operational since 2003, the scope of NSRL is to provide ion beams in support of the NASA Humans in Space program in radiobiology, physics and engineering to measure the risk and ameliorate the effect of radiation in space. Recently, it has also been recognized as the only facility in the U.S. currently capable of contributing to heavy ion radiotherapy research. Finally, this work contains a general overview of NSRL structure, capabilities and operation.

  13. Pacific Northwest Laboratory annual report for 1991 to the DOE Office of Energy Research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, J.F.

    1992-09-01

    This report summarizes progress in OHER biological research and general life sciences research programs conducted conducted at PNL in FLY 1991. The research develops the knowledge and scientific principles necessary to identify, understand, and anticipate the long- term health consequences of energy-related radiation and chemicals. Our continuing emphasis is to decrease the uncertainty of health risk estimates from existing and newly developed energy-related technologies through an increased understanding of the ways in which radiation and chemicals cause biological damage.

  14. Value impact assessment: A preliminary assessment of improvement opportunities at the Quantico Central Heating Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brambley, M.R.; Weakley, S.A.

    1990-09-01

    This report presents the results of a preliminary assessment of opportunities for improvement at the US Marine Corps (USMC) Quantico, Virginia, Central Heating Plant (CHP). This study is part of a program intended to provide the CHP staff with a computerized Artificial Intelligence (AI) decision support system that will assist in a more efficient, reliable, and safe operation of their plant. As part of the effort to provide the AI decision support system, a team of six scientists and engineers from the Pacific Northwest Laboratory (PNL) visited the plant to characterize the conditions and environment of the CHP. This assessmentmore » resulted in a list of potential performance improvement opportunities at the CHP. In this report, 12 of these opportunities are discussed and qualitatively analyzed. 70 refs., 7 figs., 6 tabs.« less

  15. Site Environmental Report for Calendar Year 2006. DOE Operations at The Boeing Company Santa Susana Field Laboratory, Area IV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Ning; Rutherford, Phil

    2007-09-01

    This Annual Site Environmental Report (ASER) for 2006 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of Boeing’s Santa Susana Field Laboratory (SSFL). In the past, the Energy Technology Engineering Center (ETEC), a government-owned, company-operated test facility, was located in Area IV. The operations in Area IV included development, fabrication, and disassembly of nuclear reactors, reactor fuel, and other radioactive materials. Other activities in the area involved the operation of large-scale liquid metal facilities that were used for testing non-nuclear liquid metal fast breeder components. All nuclear work was terminated inmore » 1988; all subsequent radiological work has been directed toward decontamination and decommissioning (D&D) of the former nuclear facilities and their associated sites. Closure of the liquid metal test facilities began in 1996. Results of the radiological monitoring program for the calendar year 2006 continue to indicate that there are no significant releases of radioactive material from Area IV of SSFL. All potential exposure pathways are sampled and/or monitored, including air, soil, surface water, groundwater, direct radiation, transfer of property (land, structures, waste), and recycling.« less

  16. Contingency Operations Support to NASA Johnson Space Center Medical Operations Division

    NASA Technical Reports Server (NTRS)

    Stepaniak, Philip; Patlach, Bob; Swann, Mark; Adams, Adrien

    2005-01-01

    The Wyle Laboratories Contingency Operations Group provides support to the NASA Johnson Space Center (JSC) Medical Operations Division in the event of a space flight vehicle accident or JSC mishap. Support includes development of Emergency Medical System (EMS) requirements, procedures, training briefings and real-time support of mishap investigations. The Contingency Operations Group is compliant with NASA documentation that provides guidance in these areas and maintains contact with the United States Department of Defense (DOD) to remain current on military plans to support NASA. The contingency group also participates in Space Operations Medical Support Training Courses (SOMSTC) and represents the NASA JSC Medical Operations Division at contingency exercises conducted worldwide by the DOD or NASA. The events of September 11, 2001 have changed how this country prepares and protects itself from possible terrorist attacks on high-profile targets. As a result, JSC is now considered a high-profile target and thus, must prepare for and develop a response to a Weapons of Mass Destruction (WMD) incident. The Wyle Laboratories Contingency Operations Group supports this plan, specifically the medical response, by providing expertise and manpower.

  17. Laboratory services series: a programmed maintenance system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tuxbury, D.C.; Srite, B.E.

    1980-01-01

    The diverse facilities, operations and equipment at a major national research and development laboratory require a systematic, analytical approach to operating equipment maintenance. A computer-scheduled preventive maintenance program is described including program development, equipment identification, maintenance and inspection instructions, scheduling, personnel, and equipment history.

  18. Differential diagnosis of primary nasopharyngeal lymphoma and nasopharyngeal carcinoma focusing on CT, MRI, and PET/CT.

    PubMed

    Cho, Kyu-Sup; Kang, Dae-Woon; Kim, Hak-Jin; Lee, Jong-Kil; Roh, Hwan-Jung

    2012-04-01

    No study has done a comparative analysis of radiologic imaging findings between primary nasopharyngeal lymphoma (PNL) and nasopharyngeal carcinoma (NPC). The purpose of this study was to analyze computed tomography (CT) and magnetic resonance (MR) images and to evaluate the maximum standardized uptake value (SUV max) of positron emission tomography (PET)/CT between PNL and NPC, knowing the imaging features that distinguish PNL from NPC. Cross-sectional study. University tertiary care facility. The authors analyzed the features on CT, MR imaging, and PET/CT of 16 patients diagnosed with PNL and 32 patients diagnosed with NPC histopathologically. Patients with PNL had a larger tumor volume and showed symmetry of tumor shape than did patients with NPC. Patients with PNL also had higher tumor homogeneity than NPC patients on CT, T2-weighted, and postcontrast MR images. All PNL patients showed a high degree of enhancement without invasion to the adjacent deep structure. The involvement of the Waldeyer ring was significantly higher in PNL patients. Cervical and retropharyngeal lymphadenopathy and PET/CT SUV max showed no significant difference between PNL and NPC. If the images present a bulky, symmetric nasopharyngeal mass with marked homogeneity, a high degree of enhancement, and a higher Waldeyer ring involvement combined with no invasion into the deep structure, PNL should be considered over NPC.

  19. Environmental assessment for the proposed construction and operation of a Genome Sequencing Facility in Building 64 at Lawrence Berkeley Laboratory, Berkeley, California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-04-01

    This document is an Environmental Assessment (EA) for a proposed project to modify 14,900 square feet of an existing building (Building 64) at Lawrence Berkeley Laboratory (LBL) to operate as a Genome Sequencing Facility. This EA addresses the potential environmental impacts from the proposed modifications to Building 64 and operation of the Genome Sequencing Facility. The proposed action is to modify Building 64 to provide space and equipment allowing LBL to demonstrate that the Directed DNA Sequencing Strategy can be scaled up from the current level of 750,000 base pairs per year to a facility that produces over 6,000,000 basemore » pairs per year, while still retaining its efficiency.« less

  20. Site Environmental Report for Calendar Year 2009. DOE Operations at The Boeing Company Santa Susana Field Laboratory, Area IV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Ning; Rutherford, Phil; Amar, Ravnesh

    2010-09-01

    This Annual Site Environmental Report (ASER) for 2009 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of Boeing’s Santa Susana Field Laboratory (SSFL). The Energy Technology Engineering Center (ETEC), a government-owned, company-operated test facility, was located in Area IV. The operations in Area IV included development, fabrication, and disassembly of nuclear reactors, reactor fuel, and other radioactive materials. Other activities in the area involved the operation of large-scale liquid metal facilities that were used for testing non-nuclear liquid metal fast breeder reactor components. All nuclear work was terminated in 1988, andmore » all subsequent radiological work has been directed toward decontamination and decommissioning (D&D) of the former nuclear facilities and their associated sites. Liquid metal research and development ended in 2002. Since May 2007, the D&D operations in Area IV have been suspended by the DOE, but the environmental monitoring and characterization programs have continued. Results of the radiological monitoring program for the calendar year 2009 continue to indicate that there are no significant releases of radioactive material from Area IV of SSFL. All potential exposure pathways are sampled and/or monitored, including air, soil, surface water, groundwater, direct radiation, transfer of property (land, structures, waste), and recycling.« less

  1. Site Environmental Report for Calendar Year 2010. DOE Operations at The Boeing Company Santa Susana Field Laboratory, Area IV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Ning; Rutherford, Phil; Amar, Ravnesh

    2011-09-01

    This Annual Site Environmental Report (ASER) for 2010 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of Boeing’s Santa Susana Field Laboratory (SSFL). The Energy Technology Engineering Center (ETEC), a government-owned, company-operated test facility, was located in Area IV. The operations in Area IV included development, fabrication, and disassembly of nuclear reactors, reactor fuel, and other radioactive materials. Other activities in the area involved the operation of large-scale liquid metal facilities that were used for testing non-nuclear liquid metal fast breeder reactor components. All nuclear work was terminated in 1988, andmore » all subsequent radiological work has been directed toward decontamination and decommissioning (D&D) of the former nuclear facilities and their associated sites. Liquid metal research and development ended in 2002. Since May 2007, the D&D operations in Area IV have been suspended by the DOE, but the environmental monitoring and characterization programs have continued. Results of the radiological monitoring program for the calendar year 2010 continue to indicate that there are no significant releases of radioactive material from Area IV of SSFL. All potential exposure pathways are sampled and/or monitored, including air, soil, surface water, groundwater, direct radiation, transfer of property (land, structures, waste), and recycling.« less

  2. Combined use of flexible ureteroscopic lithotripsy with micro-percutaneous nephrolithotomy in pediatric multiple kidney stones.

    PubMed

    Li, Jun; Wang, Wenying; Du, Yuan; Tian, Ye

    2018-03-28

    We investigated the clinical value of treating pediatric multiple kidney stones with extensive distribution using flexible ureteroscopic lithotripsy (FUL) combined with micro-percutaneous nephrolithotomy (micro-PNL). In total, 21 pediatric patients with multiple renal calculi between May 2016 and June 2017 received FUL combined with micro-PNL. The group included 13 boys and eight girls; the patients' mean age was 3.8 years (range 1-8 years). The maximum stone diameter ranged from 1.0 to 1.5 cm. FUL was first performed in the lithotomy position to fragment stones that were located in the renal pelvis, and upper and mid-renal calyx. Patients were then moved to a prone position, and micro-PNL was performed to treat lower pole stones that could not be reached by the flexible ureteroscope during FUL. Percutaneous renal access to the lower calyx was achieved using a 4.8F "all-seeing needle" with ultrasound guidance, and stone fragmentation was performed with a 200-μm holmium laser at different settings to disintegrate 1- to 2-mm fragments. All 21 pediatric patients with multiple kidney stones underwent combined FUL and micro-PNL. The stone free rate (SFR) was 85.7% (18/21). The mean surgical time was 45 min (range 30-70 min). The mean volume of irrigation fluid used was 480 mL (range 300-1200 mL). The mean surgical time for FUL and micro-PNL was 31 min and 14 min, respectively, and the mean volume of fluid used for FUL and micro-PNL was 360 mL and 120 mL, respectively. According to the modified Clavien classification, grade 1 and 2 postoperative complications occurred in five and one patients, respectively. The mean decrease in the level of hemoglobin was 0.4 g/dL (0-0.7 g/dL), and no patients required a transfusion. The average hospital stay was 3 days (range 2-5 days). Combined FUL and micro-PNL is a safe, effective, and minimally invasive operation to remove multiple renal calculi with extensive distribution in children in selected cases. Copyright © 2018

  3. Biosafety principles and practices for the veterinary diagnostic laboratory.

    PubMed

    Kozlovac, Joseph; Schmitt, Beverly

    2015-01-01

    Good biosafety and biocontainment programs and practices are critical components of the successful operation of any veterinary diagnostic laboratory. In this chapter we provide information and guidance on critical biosafety management program elements, facility requirements, protective equipment, and procedures necessary to ensure that the laboratory worker and the environment are adequately protected in the challenging work environment of the veterinary diagnostic laboratory in general and provide specific guidance for those laboratories employing molecular diagnostic techniques.

  4. Pacific Northwest National Laboratory institutional plan: FY 1996--2001

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-01-01

    This report contains the operation and direction plan for the Pacific Northwest National Laboratory of the US Department of Energy. The topics of the plan include the laboratory mission and core competencies, the laboratory strategic plan; the laboratory initiatives in molecular sciences, microbial biotechnology, global environmental change, complex modeling of physical systems, advanced processing technology, energy technology development, and medical technologies and systems; core business areas, critical success factors, and resource projections.

  5. 1992 Environmental monitoring report, Sandia National Laboratories, Albuquerque, New Mexico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Culp, T.; Cox, W.; Hwang, H.

    1993-09-01

    This 1992 report contains monitoring data from routine radiological and nonradiological environmental surveillance activities. summaries of significant environmental compliance programs in progress, such as National Environmental Policy Act documentation, environmental permits, envirorunental restoration, and various waste management programs for Sandia National Laboratories in Albuquerque, New Mexico, are included. The maximum offsite dose impact was calculated to be 0.0034 millirem. The total population within a 50-mile radius of Sandia National Laboratories/New Mexico received an estimated collective dose of 0.019 person-rem during 1992 from the laboratories` operations. As in the previous year, the 1992 operations at Sandia National Laboratories/New Mexico had nomore » discernible impact on the general public or on the environment.« less

  6. A Wildfire Behavior Modeling System at Los Alamos National Laboratory for Operational Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    S.W. Koch; R.G.Balice

    2004-11-01

    To support efforts to protect facilities and property at Los Alamos National Laboratory from damages caused by wildfire, we completed a multiyear project to develop a system for modeling the behavior of wildfires in the Los Alamos region. This was accomplished by parameterizing the FARSITE wildfire behavior model with locally gathered data representing topography, fuels, and weather conditions from throughout the Los Alamos region. Detailed parameterization was made possible by an extensive monitoring network of permanent plots, weather towers, and other data collection facilities. We also incorporated a database of lightning strikes that can be used individually as repeatable ignitionmore » points or can be used as a group in Monte Carlo simulation exercises and in other randomization procedures. The assembled modeling system was subjected to sensitivity analyses and was validated against documented fires, including the Cerro Grande Fire. The resulting modeling system is a valuable tool for research and management. It also complements knowledge based on professional expertise and information gathered from other modeling technologies. However, the modeling system requires frequent updates of the input data layers to produce currently valid results, to adapt to changes in environmental conditions within the Los Alamos region, and to allow for the quick production of model outputs during emergency operations.« less

  7. Strategies of organization and service for the critical-care laboratory.

    PubMed

    Fleisher, M; Schwartz, M K

    1990-08-01

    Critical-care medicine requires rapidity of treatment decisions and clinical management. To meet the objectives of critical-care medicine, the critical-care laboratory must consider four major aspects of laboratory organization in addition to analytical responsibilities: specimen collection and delivery, training of technologists, selection of reliable instrumentation, and efficient data dissemination. One must also consider the advantages and disadvantages of centralization vs decentralization, the influence of such a laboratory on patient care and personnel needs, and the space required for optimal operation. Centralization may lead to workflow interruption and increased turnaround time (TAT); decentralization requires redundancy of instrumentation and staff but may shorten TAT. Minimal TAT is the hallmark of efficient laboratory service. We surveyed 55 laboratories in 33 hospitals and found that virtually all hospitals with 200 or more beds had a critical-care laboratory operating as a satellite of the main laboratory. We present data on actual TAT, although these were available in only eight of the 15 routine laboratories that provided emergency service and in eight of the 40 critical-care laboratories. In meeting the challenges of an increasing workload, a reduced clinical laboratory work force, and the need to reduce TAT, changes in traditional laboratory practice are mandatory. An increased reliance on whole-blood analysis, for example, should eliminate delays associated with sample preparation, reduce the potential hazards associated with centrifugation, and eliminate excess specimen handling.

  8. Solid waste projection model: Model version 1. 0 technical reference manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilkins, M.L.; Crow, V.L.; Buska, D.E.

    1990-11-01

    The Solid Waste Projection Model (SWPM) system is an analytical tool developed by Pacific Northwest Laboratory (PNL) for Westinghouse Hanford Company (WHC). The SWPM system provides a modeling and analysis environment that supports decisions in the process of evaluating various solid waste management alternatives. This document, one of a series describing the SWPM system, contains detailed information regarding the software utilized in developing Version 1.0 of the modeling unit of SWPM. This document is intended for use by experienced software engineers and supports programming, code maintenance, and model enhancement. Those interested in using SWPM should refer to the SWPM Modelmore » User's Guide. This document is available from either the PNL project manager (D. L. Stiles, 509-376-4154) or the WHC program monitor (B. C. Anderson, 509-373-2796). 8 figs.« less

  9. Battelle's Marine Research Laboratory, Sequim

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Becker, C.D.; Strand, J.A.

    Scientists at Battelle's Marine Research Laboratory (MRL) in Sequim, Washington study the effect of human activities on marine ecosystems, with emphasis on near shore and estuarine environments. The laboratory provides research and development assistance to industry and government agencies engaged in management of marine technologies, operation of coastal power utilities, protection of the marine environment, and related areas. This paper outlines and discusses the functions of Battelle's MRL, it's history, it's unique features, it's areas of expertise, it's current programs, and it's cooperating agencies.

  10. An acidic pectin lyase from Aspergillus niger with favourable efficiency in fruit juice clarification.

    PubMed

    Xu, S X; Qin, X; Liu, B; Zhang, D Q; Zhang, W; Wu, K; Zhang, Y H

    2015-02-01

    The pectin lyase gene pnl-zj5a from Aspergillus niger ZJ5 was identified and expressed in Pichia pastoris. PNL-ZJ5A was purified by ultrafiltration, anion exchange and gel chromatography. The Km and Vmax values determined using citrus pectin were 0.66 mg ml(-1) and 32.6 μmol min(-1) mg(-1) , respectively. PNL-ZJ5A exhibited optimal activity at 43°C and retained activity over 25-50°C. PNL-ZJ5A was optimally active at pH 5 and effective in apple juice clarification. Compared with controls, PNL-ZJ5A increased the fruit juice yield significantly. Furthermore, PNL-ZJ5A reduced the viscosity of apple juice by 38.8% and increased its transmittance by 86.3%. PNL-ZJ5A combined with a commercial pectin esterase resulted in higher juice volume. © 2014 The Society for Applied Microbiology.

  11. Comparison of miniaturized percutaneous nephrolithotomy and flexible ureterorenoscopy for moderate size renal stones in elderly patients.

    PubMed

    Ozgor, Faruk; Yanaral, Fatih; Savun, Metin; Ozdemir, Harun; Caglar, Ufuk; Sarilar, Omer

    2018-06-01

    Life expectancy has become longer, thus the number of elderly people who require treatment for nephrolithiasis has increased. We aimed to analyze the efficacy of flexible ureterorenoscopy (f-URS) and miniaturized percutaneous nephrolithotomy (mPNL) in the management of 10 and 30 mm renal stones in patients aged >60 years. In prospective non-randomized series, the data of patients who underwent f-URS or mPNL for kidney stones between July 2013 and July 2016 were analyzed. The procedure was accepted as successful if the patient was achieved complete stone clearance according to CT imaging between 1-3 months postoperatively. In total 60 patients and 58 patients were underwent f-URS and mPNL, respectively. The mean operation time, fluoroscopy time and hospitalization time were significantly shorter for the f-URS (p < 0.001, p < 0.001, p < 0.001, respectively). According to Clavien classification system, complication rates were not significantly different between the groups (p = 0.673). The stone-free rate was 81.7% for the f-URS group and 77.6% for the mPNL group after a single-session procedure (p = 0.747). Calcium oxalate monohydrate stones were the most common stone type in both groups. In multivariate analysis, multiple stones localization was only independent factor to predict complications. Our study had showed that both f-URS and mPNL are effective treatment modalities for 10-30-mm renal stones in elderly patients. Additionally, presence of stones in multiple location was the only predictive factor for complication development. Copyright © 2017 Kaohsiung Medical University. Published by Elsevier Taiwan. All rights reserved.

  12. Radiation control program at the Donald W. Douglas Laboratories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, M.L.; Willis, C.A.

    1972-01-01

    From third Health Physics Society midyear topical symposium; Los Angeles, California, USA (29 Jan 1969). See CONF-690103P1. The McDonnell Douglas Astronautics Company built and operates the Donald W. Douglas Laboratories at Richland, Washington. The 57,600 ft/sup 2/ facility is located on a 112 acre site. One wing of this multipurpose laboratory houses a radioisotope laboratory and a composite fuels laboratory. The problem of two years of operation of the hot laboratory and fuels research laboratory is discussed. To limit the accident potertial, a radioactive storage building is utilized. Materials are stored in sealed containers. The procedural control of the inventorymore » is illustrated. Disposal of high specific activity waste has posed some unique problems. Single swabs can contain more than 100 curies. An agreement with the State of Washington licensing agency and the waste disposal company permits shipment of waste. Radiation dosimetry for /sup 147/Pm and its associated 66 KeV gamma has been difficult. The angular dependence of the film dosimeter is shown where there is a distributed source causing an error of a factor 3 in the dosimetry. The solution to this problem is shown. (auth)« less

  13. Site environmental report for 2009 : Sandia National Laboratories, California.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larsen, Barbara L.

    2010-06-01

    Sandia National Laboratories, California (SNL/CA) is a government-owned/contractor-operated laboratory. Sandia Corporation, a Lockheed Martin Company, operates the laboratory for the Department of Energy's National Nuclear Security Administration (NNSA). The NNSA Sandia Site Office oversees operations at the site, using Sandia Corporation as a management and operating contractor. This Site Environmental Report for 2009 was prepared in accordance with DOE Order 231.1A (DOE 2004a). The report provides a summary of environmental monitoring information and compliance activities that occurred at SNL/CA during calendar year 2009. General site and environmental program information is also included. The Site Environmental Report is divided into tenmore » chapters. Chapter 1, the Executive Summary, highlights compliance and monitoring results obtained in 2009. Chapter 2 provides a brief introduction to SNL/CA and the existing environment found on site. Chapter 3 summarizes SNL/CA's compliance activities with the major environmental requirements applicable to site operations. Chapter 4 presents information on environmental management, performance measures, and environmental programs. Chapter 5 presents the results of monitoring and surveillance activities in 2009. Chapter 6 discusses quality assurance. Chapters 7 through 9 provide supporting information for the report and Chapter 10 is the report distribution list.« less

  14. Sortie laboratory, phase B technical summary. [design and operational requirements

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The design and operational requirements which evolved from Sortie Lab (SL) analysis are summarized. A source of requirements for systems is given along with experimental support for the SL, baseline. Basic design data covered include: configuration definition, mission analysis, experimental integration, safety, and logistics. A technical summary outlines characteristics which reflect the influence of the growth in SL capability and the results of the mission and operational analysis. Each of the selected areas is described in terms of objectives, equipment, operational concept, and support requirements.

  15. Reflectance Experiment Laboratory (RELAB) Description and User's Manual

    NASA Technical Reports Server (NTRS)

    Pieters, Carle M.; Hiroi, Takahiro; Pratt, Steve F.; Patterson, Bill

    2004-01-01

    Spectroscopic data acquired in the laboratory provide the interpretive foundation upon which compositional information about unexplored or unsampled planetary surfaces is derived from remotely obtained reflectance spectra. The RELAB is supported by NASA as a multi-user spectroscopy facility, and laboratory time can be made available at no charge to investigators who are in funded NASA programs. RELAB has two operational spectrometers available to NASA scientists: 1) a near- ultraviolet, visible, and near-infrared bidirectional spectrometer and 2) a near- and mid- infrared FT-IR spectrometer. The overall purpose of the design and operation of the RELAB bidirectional spectrometer is to obtain high precision, high spectral resolution, bidirectional reflectance spectra of earth and planetary materials. One of the key elements of its design is the ability to measure samples using viewing geometries specified by the user. This allows investigators to simulate, under laboratory conditions, reflectance spectra obtained remotely (i.e., with spaceborne, telescopic, and airborne systems) as well as to investigate geometry dependent reflectance properties of geologic materials. The Nicolet 740 FT-IR spectrometer currently operates in reflectance mode from 0.9 to 25 Fm. Use and scheduling of the RELAB is monitored by a 4-member advisory committee. NASA investigators should direct inquiries to the Science Manager or RELAB Operator.

  16. Laboratory Directed Research and Development Annual Report FY 2017

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, Kelly O.

    A national laboratory must establish and maintain an environment in which creativity and innovation are encouraged and supported in order to fulfill its missions and remain viable in the long term. As such, multiprogram laboratories are given discretion to allocate a percentage of their operating budgets to support research and development projects that align to PNNL’s and DOE’s missions and support the missions of other federal agencies, including DHS, DOD, and others. DOE Order 413.2C sets forth DOE’s Laboratory Directed Research and Development (LDRD) policy and guidelines for DOE multiprogram laboratories, and it authorizes the national laboratories to allocate upmore » to 6 percent of their operating budgets to fund the program. LDRD is innovative research and development, selected by the Laboratory Director or his/her designee, for the purpose of maintaining the scientific and technological vitality of the Laboratory. The projects supported by LDRD funding all have demonstrable ties to DOE/DHS missions and may also be relevant to the missions of other federal agencies that sponsor work at the Laboratory. The program plays a key role in attracting the best and brightest scientific staff, which is needed to serve the highest priority DOE mission objectives. Individual project reports comprise the bulk of this LDRD report. The Laboratory focuses its LDRD research on scientific assets that often address more than one scientific discipline.« less

  17. Laboratory Directed Research and Development Annual Report FY 2016

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, Kelly O.

    A national laboratory must establish and maintain an environment in which creativity and innovation are encouraged and supported in order to fulfill its missions and remain viable in the long term. As such, multiprogram laboratories are given discretion to allocate a percentage of their operating budgets to support research and development projects that align to PNNL’s and DOE’s missions and support the missions of other federal agencies, including DHS, DOD, and others. DOE Order 413.2C sets forth DOE’s Laboratory Directed Research and Development (LDRD) policy and guidelines for DOE multiprogram laboratories, and it authorizes the national laboratories to allocate upmore » to 6 percent of their operating budgets to fund the program. LDRD is innovative research and development, selected by the Laboratory Director or his/her designee, for the purpose of maintaining the scientific and technological vitality of the Laboratory. The projects supported by LDRD funding all have demonstrable ties to DOE/DHS missions and may also be relevant to the missions of other federal agencies that sponsor work at the Laboratory. The program plays a key role in attracting the best and brightest scientific staff, which is needed to serve the highest priority DOE mission objectives. Individual project reports comprise the bulk of this LDRD report. The Laboratory focuses its LDRD research on scientific assets that often address more than one scientific discipline.« less

  18. The four free-operant freedoms

    PubMed Central

    Lindsley, Ogden R.

    1996-01-01

    This article reviews early free-operant conditioning laboratory research and applications. The seldom-mentioned four free-operant freedoms are described for the first time in detail. Most current behavior analysts do not realize that the freedom to form responses and the freedom to speed responses were crucial steps in designing free-operant operanda in the 1950s. These four freedoms were known by the laboratory researchers of the 1950s to the point that, along with operanda design, Sidman (1960) did not feel the need to detail them in his classic, Tactics of Scientific Research. The dimensions of freedom in the operant were so well understood and accepted in the 1950s that most thought it redundant to use the term free operant. These issues are reviewed in some detail for younger behavior analysts who did not have the opportunity of learning them firsthand. PMID:22478258

  19. The Pathology Laboratory Act 2007 explained.

    PubMed

    Looi, Lai-Meng

    2008-06-01

    The past century has seen tremendous changes in the scope and practice of pathology laboratories in tandem with the development of the medical services in Malaysia. Major progress was made in the areas of training and specialization of pathologists and laboratory technical staff. Today the pathology laboratory services have entered the International arena, and are propelled along the wave of globalization. Many new challenges have emerged as have new players in the field. Landmark developments over the past decade include the establishment of national quality assurance programmes, the mushrooming of private pathology laboratories, the establishment of a National Accreditation Standard for medical testing laboratories based on ISO 15189, and the passing of the Pathology Laboratory Act in Parliament in mid-2007. The Pathology Laboratory Act 2007 seeks to ensure that the pathology laboratory is accountable to the public, meets required standards of practice, participates in Quality Assurance programmes, is run by qualified staff, complies with safety requirements and is subject to continuous audit. The Act is applicable to all private laboratories (stand alone or hospital) and laboratories in statutory bodies (Universities, foundations). It is not applicable to public laboratories (established and operated by the government) and side-room laboratories established in clinics of registered medical or dental practitioners for their own patients (tests as in the First and Second Schedules respectively). Tests of the Third Schedule (home test blood glucose, urine glucose, urine pregnancy test) are also exempted. The Act has 13 Parts and provides for control of the pathology laboratory through approval (to establish and maintain) and licensing (to operate or provide). The approval or license may only be issued to a sole proprietor, partnership or body corporate, and then only if the entity includes a registered medical practitioner. Details of personnel qualifications and

  20. Development opportunities for hospital clinical laboratory joint ventures.

    PubMed

    Van Riper, J A

    1995-01-01

    Regional health-care providers are being given the opportunity to collaborate in specialty health-care services. Collaboration to achieve superior economies of scale is very effective in the clinical laboratory industry. National laboratory chains are consolidating and enhancing their control of the industry to ensure their historic profitability. National companies have closed many laboratory facilities and have laid off substantial numbers of laboratory personnel. Health-care providers can regain control of their locally generated laboratory health-care dollars by joining forces with clinical laboratory joint ventures. Laboratorians can assist the healthcare providers in bringing laboratory services and employment back to the local community. New capital for operational development and laboratory information systems will help bring the laboratory to the point of care. The independent regional laboratory is focused on supporting the medical needs of the community. The profit generated from a laboratory joint venture is shared among local health-care providers, supporting their economic viability. The laboratories' ability to contribute to the development of profit-making ventures will provide capital for new laboratory development. All of the above will ensure the clinical laboratories' role in providing quality health care to our communities and employment opportunities for laboratory personnel.

  1. Retrograde intrarenal surgery versus percutaneous lithotripsy to treat renal stones 2-3 cm in diameter.

    PubMed

    Zengin, Kursad; Tanik, Serhat; Karakoyunlu, Nihat; Sener, Nevzat Can; Albayrak, Sebahattin; Tuygun, Can; Bakirtas, Hasan; Imamoglu, M Abdurrahim; Gurdal, Mesut

    2015-01-01

    Retrograde intrarenal surgery (RIRS) performed using a flexible ureterorenoscope marked the beginning of a new era in urology. Today, even staghorn stones are successfully treated via RIRS. The recommended treatment for larger stones is percutaneous nephrolithotomy (PNL). However, the question of whether PNL or RIRS should be the first-line treatment option for larger stones remains controversial. In this study, we contribute to the debate by comparing the success and complication rates of PNL and RIRS that were used to treat renal pelvis stones 2-3 cm in diameter. The medical records of 154 patients (74 PNL, 80 RIRS) were retrospectively evaluated. PNL patients were placed in Group 1 and RIRS patients in Group 2. The complete stone-free rates were 95.5% in the PNL group and 80.6% in the RIRS group 1 month postoperatively (P = 0.061). The respective complication rates (evaluated using the Clavien system) were 13.5% and 8.8% (P = 0.520). RIRS affords a comparable success rate, causes fewer complications than PNL, and seems to be a promising alternative to PNL when larger stones are to be treated. Prospective randomized controlled trials are needed to confirm these findings.

  2. Acoustic testing of a 1.5 pressure ratio low tip speed fan with a serrated rotor (QEP fan B scale model). [reduction of engine noise

    NASA Technical Reports Server (NTRS)

    Kazin, S. B.; Paas, J. E.; Minzner, W. R.

    1973-01-01

    A scale model of the bypass flow region of a 1.5 pressure ratio, single stage, low tip speed fan was tested with a serrated rotor leading edge to determine its effects on noise generation. The serrated rotor was produced by cutting teeth into the leading edge of the nominal rotor blades. The effects of speed and exhaust nozzle area on the scale models noise characteristics were investigated with both the nominal rotor and serrated rotor. Acoustic results indicate the serrations reduced front quadrant PNL's at takeoff power. In particular, the 200 foot (61.0 m) sideline noise was reduced from 3 to 4 PNdb at 40 deg for nominal and large nozzle operation. However, the rear quadrant maximum sideline PNL's were increased 1.5 to 3 PNdb at approach thust and up to 2 PNdb at takeoff thust with these serrated rotor blades. The configuration with the serrated rotor produced the lowest maximum 200 foot (61.0 m) sideline PNL for any given thust when the large nozzle (116% of design area) was employed.

  3. Pacific Northwest Laboratory Annual Report for 1992 to the DOE Office of Energy Research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kreml, S.A.; Park, J.F.

    1993-06-01

    This report summarizes progress in OHER biological research and general life sciences research programs conducted at PNL in FY 1992. The research develops the knowledge and fundamental principles necessary to identify, understand, and anticipate the long-term health consequences of energy-related radiation and chemicals. Our continuing emphasis is to decrease the uncertainty of health risk estimates from energy-related technologies through an increase understanding of the ways in which radiation and chemicals cause biological damage. Descriptors of individual research projects as detailed in this report one separately abstracted and indexed for the database.

  4. Enhancement of solubility, purification and inclusion-bodies-refolding of an active pectin lyase from Penicillium occitanis expressed in Escherichia coli.

    PubMed

    Hadj Sassi, Azza; Trigui-Lahiani, Hèla; Abdeljalil, Salma; Gargouri, Ali

    2017-02-01

    Pectin lyase (pnl) is the only pectinase able to hydrolyze directly the highly methylated pectin without liberating the toxic methanol and without disturbing ester content responsible for specific aroma of juices. The cDNA of Penicillium occitanis pnl (mature form) was cloned into pET-21a as expression vector and over-expressed into Esherichia coli. Most of recombinant pnl was expressed as inclusion bodies. Pnl activity was confirmed by colorimetric assay. To enhance the solubility yield of the expressed pnl, the effects of induction temperature, host strain and expression level were optimized. Maximal production of functional pnl was obtained after induction by 0.4mM IPTG at 30°C and 150rpm for 16h. Interestingly, the use of Origami host strain, having an oxidized cytoplasm favoring disulfide bonds formation required for the active conformation of the enzyme, has significantly improved the yield of the soluble active form of recombinant pnl. This pnl was successfully purified through a single step purification using His-Trap affinity column chromatography. This work is the first to report pnl expression into Origami strain. Alternatively, the inclusion bodies were isolated, denatured by high concentration of urea and gradually refolded by successive dialysis, leading to their transformation into soluble and active form. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Platelet-to-Lymphocyte Ratio: A New Factor for Predicting Systemic Inflammatory Response Syndrome after Percutaneous Nephrolithotomy.

    PubMed

    Cetinkaya, Mehmet; Buldu, Ibrahim; Kurt, Omer; Inan, Ramazan

    2017-08-29

    The first purpose of this study was to reveal factors affecting the postoperative development of systemic inflammatory response syndrome (SIRS) in patients undergoing standard percutaneous nephrolithotomy (PNL) for renal stones. The second purpose was to determine the role of the preoperative platelet-to-lymphocyte ratio (PLR) and the neutrophil-to-lymphocyte ratio (NLR) in the prediction of SIRS.Matarials and Methods: In total, 192 patients who had undergone conventional PNL for renal stones from 2013 to 2015 were included in the study. SIRS developed postoperatively in 41 (21.3%) patients. The patients were divided into SIRS and non-SIRS groups, and the effects of the PLR, NLR, and other demographic and operative data were investigated to predict the development of SIRS. Variables significant in the univariate analysis were evaluated using a multiple logistic regression model to determine the independent risk factors for developing SIRS after PNL. Univariate analysis revealed significant differences in the preoperative PLR (P < .001), preoperative NLR (P = .018), number of access sites (P < .001), mean renal parenchymal thickness (P = .02), operative time (P < .001), decrease in hemoglobin (P = .016), length of hospital stay (P < .001), stone-free status (P = .023), and complication rate between the two groups of patients. However, multivariate analysis showed that only the PLR and the number of access sites were independent factors affecting the development of SIRS. When the PLR cut-off value was 114.1, development of SIRS was predicted with 80.4% sensitivity and 60.2% specificity. The preoperative PLR is an effective and inexpensive biomarker with which to predict SIRS after PNL. In particular, we recommend close monitoring of patients with a PLR of >114.1 because of the possibledevelopment of serious complications.

  6. Competition between Naegleria fowleri and Free Living Amoeba Colonizing Laboratory Scale and Operational Drinking Water Distribution Systems.

    PubMed

    Miller, Haylea C; Wylie, Jason T; Kaksonen, Anna H; Sutton, David; Puzon, Geoffrey J

    2018-03-06

    Free living amoebae (FLA), including pathogenic Naegleria fowleri, can colonize and grow within pipe wall biofilms of drinking water distribution systems (DWDSs). Studies on the interactions between various FLA species in biofilms are limited. Understanding the interaction between FLA and the broader biofilm ecology could help better predict DWDS susceptibility to N. fowleri colonization. The aim of this study was to determine if N. fowleri and other FLAs ( Naegleria, Vermamoeba, Willaertia, and Vahlkampfia spp.) cocolonize DWDS biofilm. FLAs commonly isolated from DWDSs ( N. fowleri, V. vermiformis, and N. lovaniensis) were introduced into laboratory-scale biomonitors to determine the impact of these amoebae on N. fowleri's presence and viability. Over 18 months, a single viable amoebae ( N. fowleri, N. lovaniensis, or V. vermiformis) was detected in each biofilm sample, with the exception of N. lovaniensis and N. fowleri, which briefly cocolonized biofilm following their coinoculation. The analysis of biofilm and bulk water samples from operational DWDSs revealed a similar lack of cocolonization with a single FLA detected in 99% ( n = 242) of samples. Interestingly, various Naegleria spp. did colonize the same DWDS locations but at different times. This knowledge furthers the understanding of ecological factors which enable N. fowleri to colonize and survive within operational DWDSs and could aid water utilities to control its occurrence.

  7. Overview of the NASA space radiation laboratory.

    PubMed

    La Tessa, Chiara; Sivertz, Michael; Chiang, I-Hung; Lowenstein, Derek; Rusek, Adam

    2016-11-01

    The NASA Space Radiation Laboratory (NSRL) is a multidisciplinary center for space radiation research funded by NASA and located at the Brookhaven National Laboratory (BNL), Upton NY. Operational since 2003, the scope of NSRL is to provide ion beams in support of the NASA Humans in Space program in radiobiology, physics and engineering to measure the risk and ameliorate the effect of radiation in space. Recently, it has also been recognized as the only facility in the U.S. currently capable of contributing to heavy ion radiotherapy research. This work contains a general overview of NSRL structure, capabilities and operation. Copyright © 2016 The Committee on Space Research (COSPAR). All rights reserved.

  8. Training and Tactical Operationally Responsive Space Operations

    NASA Astrophysics Data System (ADS)

    Sorensen, B.; Strunce, R., Jr.

    to realize the full potential of the ORS approach to the support of in-theater tactical forces is the development of satellite tasking, interface, and data retrieval capabilities and mission operations approaches from a warfighter centered perspective, and the development of realistic training and simulation capabilities that will allow development, demonstration, and assessment of ORS tactical CONOPS. A system for Training and Tactical ORS Operations (TATOO) is currently being developed. This system will support development and evaluation of ORS specific CONOPS approaches, and training and evaluation of those CONOPS implementations through dedicated training capabilities, facilities, and exercises. TATOO will support the operational side of ORS and will merge with the revolutionary ORS spacecraft development and deployment processes to make the ORS paradigm a reality. TATOO's primary objective is to support the In-Theater Commander and Warfighter by developing, training, and assessing ORS mission CONOPS for In-Theater tasking, scheduling, interface, and data retrieval for TacSats owned by In-Theater Commanders. TATOO provides a laboratory/classroom environment for the development, test and evaluation of ORS Tactical Mission CONOPS for In-Theater ORS operations. The TATOO laboratory will also be used to develop, evaluate, and document ORS Mission CONOPS for tactical ISR and other ORS missions. Within this framework, the laboratory/classroom can be used to develop the necessary training materials and procedures, as well as conduct training exercises that emphasize the training of In-Theater personal with regard to: Tactical Ground Station Mission Operations; Tactical Operations for Mission Tasking and Scheduling; Tactical Mission Data Retrieval; and, Support for Warfighter Operations.

  9. Idaho National Laboratory Cultural Resource Management Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lowrey, Diana Lee

    As a federal agency, the U.S. Department of Energy has been directed by Congress, the U.S. president, and the American public to provide leadership in the preservation of prehistoric, historic, and other cultural resources on the lands it administers. This mandate to preserve cultural resources in a spirit of stewardship for the future is outlined in various federal preservation laws, regulations, and guidelines such as the National Historic Preservation Act, the Archaeological Resources Protection Act, and the National Environmental Policy Act. The purpose of this Cultural Resource Management Plan is to describe how the Department of Energy, Idaho Operations Officemore » will meet these responsibilities at the Idaho National Laboratory. This Laboratory, which is located in southeastern Idaho, is home to a wide variety of important cultural resources representing at least 13,500 years of human occupation in the southeastern Idaho area. These resources are nonrenewable; bear valuable physical and intangible legacies; and yield important information about the past, present, and perhaps the future. There are special challenges associated with balancing the preservation of these sites with the management and ongoing operation of an active scientific laboratory. The Department of Energy, Idaho Operations Office is committed to a cultural resource management program that accepts these challenges in a manner reflecting both the spirit and intent of the legislative mandates. This document is designed for multiple uses and is intended to be flexible and responsive to future changes in law or mission. Document flexibility and responsiveness will be assured through annual reviews and as-needed updates. Document content includes summaries of Laboratory cultural resource philosophy and overall Department of Energy policy; brief contextual overviews of Laboratory missions, environment, and cultural history; and an overview of cultural resource management practices. A series of

  10. Idaho National Laboratory Cultural Resource Management Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lowrey, Diana Lee

    2009-02-01

    As a federal agency, the U.S. Department of Energy has been directed by Congress, the U.S. president, and the American public to provide leadership in the preservation of prehistoric, historic, and other cultural resources on the lands it administers. This mandate to preserve cultural resources in a spirit of stewardship for the future is outlined in various federal preservation laws, regulations, and guidelines such as the National Historic Preservation Act, the Archaeological Resources Protection Act, and the National Environmental Policy Act. The purpose of this Cultural Resource Management Plan is to describe how the Department of Energy, Idaho Operations Officemore » will meet these responsibilities at the Idaho National Laboratory. This Laboratory, which is located in southeastern Idaho, is home to a wide variety of important cultural resources representing at least 13,500 years of human occupation in the southeastern Idaho area. These resources are nonrenewable; bear valuable physical and intangible legacies; and yield important information about the past, present, and perhaps the future. There are special challenges associated with balancing the preservation of these sites with the management and ongoing operation of an active scientific laboratory. The Department of Energy, Idaho Operations Office is committed to a cultural resource management program that accepts these challenges in a manner reflecting both the spirit and intent of the legislative mandates. This document is designed for multiple uses and is intended to be flexible and responsive to future changes in law or mission. Document flexibility and responsiveness will be assured through annual reviews and as-needed updates. Document content includes summaries of Laboratory cultural resource philosophy and overall Department of Energy policy; brief contextual overviews of Laboratory missions, environment, and cultural history; and an overview of cultural resource management practices. A series of

  11. Idaho National Laboratory Cultural Resource Management Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Julie Braun Williams

    As a federal agency, the U.S. Department of Energy has been directed by Congress, the U.S. president, and the American public to provide leadership in the preservation of prehistoric, historic, and other cultural resources on the lands it administers. This mandate to preserve cultural resources in a spirit of stewardship for the future is outlined in various federal preservation laws, regulations, and guidelines such as the National Historic Preservation Act, the Archaeological Resources Protection Act, and the National Environmental Policy Act. The purpose of this Cultural Resource Management Plan is to describe how the Department of Energy, Idaho Operations Officemore » will meet these responsibilities at Idaho National Laboratory in southeastern Idaho. The Idaho National Laboratory is home to a wide variety of important cultural resources representing at least 13,500 years of human occupation in the southeastern Idaho area. These resources are nonrenewable, bear valuable physical and intangible legacies, and yield important information about the past, present, and perhaps the future. There are special challenges associated with balancing the preservation of these sites with the management and ongoing operation of an active scientific laboratory. The Department of Energy, Idaho Operations Office is committed to a cultural resource management program that accepts these challenges in a manner reflecting both the spirit and intent of the legislative mandates. This document is designed for multiple uses and is intended to be flexible and responsive to future changes in law or mission. Document flexibility and responsiveness will be assured through regular reviews and as-needed updates. Document content includes summaries of Laboratory cultural resource philosophy and overall Department of Energy policy; brief contextual overviews of Laboratory missions, environment, and cultural history; and an overview of cultural resource management practices. A series of

  12. Routine intraoperative completion angiography after coronary artery bypass grafting and 1-stop hybrid revascularization results from a fully integrated hybrid catheterization laboratory/operating room.

    PubMed

    Zhao, David X; Leacche, Marzia; Balaguer, Jorge M; Boudoulas, Konstantinos D; Damp, Julie A; Greelish, James P; Byrne, John G; Ahmad, Rashid M; Ball, Stephen K; Cleator, John H; Deegan, Robert J; Eagle, Susan S; Fong, Pete P; Fredi, Joseph L; Hoff, Steven J; Jennings, Henry S; McPherson, John A; Piana, Robert N; Pretorius, Mias; Robbins, Mark A; Slosky, David A; Thompson, Annemarie

    2009-01-20

    This study sought to report our experience with a routine completion angiogram after coronary artery bypass surgery (CABG) and simultaneous (1-stop) percutaneous coronary intervention (PCI) at the time of CABG performed in the hybrid catheterization laboratory/operating room. The value of a routine completion angiogram after CABG and 1-stop hybrid CABG/PCI remains unresolved. Between April 2005 and July 2007, 366 consecutive patients underwent CABG surgery, with (n = 112) or without (n = 254) concomitant 1-stop PCI (hybrid), all with completion angiography before chest closure. Among the 112 1-stop hybrid CABG/PCI patients, 67 (60%) underwent a planned hybrid procedure based on pre-operative assessment, whereas 45 (40%) underwent open-chest PCI (unplanned hybrid) based on intraoperative findings. Among the 796 CABG grafts (345 left internal mammary artery, 12 right internal mammary artery/radial, and 439 veins), 97 (12%) angiographic defects were identified. Defects were repaired with either a minor adjustment of the graft (n = 22, 2.8%), with intraoperative open-chest PCI (unplanned hybrid, n = 48, 6%) or with traditional surgical revision (n = 27, 3.4%). Hybrid patients had clinical outcomes similar to standard CABG patients. Routine completion angiography detected 12% of grafts with important angiographic defects. One-stop hybrid coronary revascularization is reasonable, safe, and feasible. Combining the tools of the catheterization laboratory and operating room greatly enhances the options available to the surgeon and cardiologist for patients with complex coronary artery disease.

  13. Variety of neutron sensors based on scintillating glass waveguides

    NASA Astrophysics Data System (ADS)

    Bliss, Mary; Craig, Richard A.

    1995-04-01

    Pacific Northwest Laboratory (PNL) has fabricated cerium-activated lithium silicate glass scintillating fiber waveguide neutron sensors via a hot-downdraw process. These fibers typically have a transmission length (e-1 length) of greater than 2 meters. The underlying physics of, the properties of, and selected devices incorporating these fibers are described. These fibers constitute an enabling technology for a wide variety of neutron sensors.

  14. In vitro maturation of immature thymocytes into immunocompetent T cells in the absence of direct thymic influence.

    PubMed

    Irlé, C; Piguet, P F; Vassalli, P

    1978-07-01

    Peanut lectin (PNL) binds to a majority of mouse thymocytes (Thc) in suspension. By using cell affinity chromatography on a column of anti-PNL antibody, Thc populations at least 96 percent pure in PNL + or - cells, as judged by immunofluorescence, were obtained. PNL(+) cells are rich in Thy 1 and poor in H(2) antigens, cortisone sensitive, unresponsive to phytohemagglutinin (PHA), and immunologically incompetent, as judged by mixed lymphocyte reaction, popliteal lymph node graft-versus-host assay, and by testing helper activity in a primary in vitro antibody response to sheep erythrocytes; the converse is true of PNL(-) cells. Thus, PNL(+) and (-) cells appear to correspond to cortical and medullary Thc, respectively, as previously suggested. In culture, PNL(+) Thc show poor viability and a weak proliferative response to concanavalin A (Con A), except when supernate (SUP) of 24 h Con A stimulated lymph node lymphocyte cultures, or irradiated lymph node cells, are added, in which cases a strong proliferative response to the mitogen is observed. A variety of control experiments showed that the proliferating cells did not result from preferential stimulation of a few contaminating PNL(-) Thc present in the PNL(+) Thc cultures. The blasts resulting from PNL(+) Thc proliferation display mitogen-induced cytotoxicity, and give rise to a population of medium-sized lymphocytes, mostly PNL(-), poor in Thy 1 and rich in H(2) antigens, PHA responsive, and immunologically competent in the above-mentioned assays. Fresh PNL(+) Thc responded in mixed lymphocyte reaction in the presence of SUP (lectin depleted) and since incubation in SUP alone did not confer reactivity on PNL(+) Thc, it appears therefore that (a) immature Thc possess alloantigen and mitogen-specific surface receptors but lack the capacity to respond by proliferation to receptor triggering without the help of extracellular factor(s) released by mature lymphoid cells stimulated by mitogens (b) cell division is

  15. Experimental and operational modal analysis of a laboratory scale model of a tripod support structure.

    NASA Astrophysics Data System (ADS)

    Luczak, M. M.; Mucchi, E.; Telega, J.

    2016-09-01

    The goal of the research is to develop a vibration-based procedure for the identification of structural failures in a laboratory scale model of a tripod supporting structure of an offshore wind turbine. In particular, this paper presents an experimental campaign on the scale model tested in two stages. Stage one encompassed the model tripod structure tested in air. The second stage was done in water. The tripod model structure allows to investigate the propagation of a circumferential representative crack of a cylindrical upper brace. The in-water test configuration included the tower with three bladed rotor. The response of the structure to the different waves loads were measured with accelerometers. Experimental and operational modal analysis was applied to identify the dynamic properties of the investigated scale model for intact and damaged state with different excitations and wave patterns. A comprehensive test matrix allows to assess the differences in estimated modal parameters due to damage or as potentially introduced by nonlinear structural response. The presented technique proves to be effective for detecting and assessing the presence of representative cracks.

  16. Guidelines on Good Clinical Laboratory Practice

    PubMed Central

    Ezzelle, J.; Rodriguez-Chavez, I. R.; Darden, J. M.; Stirewalt, M.; Kunwar, N.; Hitchcock, R.; Walter, T.; D’Souza, M. P.

    2008-01-01

    A set of Good Clinical Laboratory Practice (GCLP) standards that embraces both the research and clinical aspects of GLP were developed utilizing a variety of collected regulatory and guidance material. We describe eleven core elements that constitute the GCLP standards with the objective of filling a gap for laboratory guidance, based on IND sponsor requirements, for conducting laboratory testing using specimens from human clinical trials. These GCLP standards provide guidance on implementing GLP requirements that are critical for laboratory operations, such as performance of protocol-mandated safety assays, peripheral blood mononuclear cell processing and immunological or endpoint assays from biological interventions on IND-registered clinical trials. The expectation is that compliance with the GCLP standards, monitored annually by external audits, will allow research and development laboratories to maintain data integrity and to provide immunogenicity, safety, and product efficacy data that is repeatable, reliable, auditable and that can be easily reconstructed in a research setting. PMID:18037599

  17. Fort Irwin integrated resource assessment. Volume 3: Sitewide Energy Project identification for buildings and facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keller, J.M.; Dittmer, A.L.; Elliott, D.B.

    1995-02-01

    The U.S. Army Forces Command (FORSCOM) has tasked the U.S. Department of Energy (DOE) Federal Energy Management Program (FEMP), supported by the Pacific Northwest Laboratory, to identify, evaluate, and assist in acquiring all cost-effective energy projects at Fort Irwin. This is part of a model program that PNL is designing to support energy-use decisions in the federal sector. This report provides the results of the fossil fuel and electric energy resource opportunity (ERO) assessments performed by PNL at the FORSCOM Fort Irwin facility located near Barstow, California. It is a companion report to Volume 1, Executive Summary, and Volume 2,more » Baseline Detail. The results of the analyses of EROs are presented in 16 common energy end-use categories (e.g., boilers and furnaces, service hot water, and building lighting). A narrative description of each ERO is provided, along with a table detailing information on the installed cost, energy and dollar savings; impacts on operations and maintenance (O&M); and, when applicable, a discussion of energy supply and demand, energy security, and environmental issues. A description of the evaluation methodologies and technical and cost assumptions is also provided for each ERO. Summary tables present the cost-effectiveness of energy end-use equipment before and after the implementation of each ERO and present the results of the life-cycle cost (LCC) analysis indicating the net present valve (NPV) and savings-to-investment ratio (SIR) of each ERO.« less

  18. Sandia National Laboratories Facilities Management and Operations Center Design Standards Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peterson, Timothy L.

    2014-09-01

    At Sandia National Laboratories in New Mexico (SNL/NM), the design, construction, operation, and maintenance of facilities is guided by industry standards, a graded approach, and the systematic analysis of life cycle benefits received for costs incurred. The design of the physical plant must ensure that the facilities are "fit for use," and provide conditions that effectively, efficiently, and safely support current and future mission needs. In addition, SNL/NM applies sustainable design principles, using an integrated whole-building design approach, from site planning to facility design, construction, and operation to ensure building resource efficiency and the health and productivity of occupants. Themore » safety and health of the workforce and the public, any possible effects on the environment, and compliance with building codes take precedence over project issues, such as performance, cost, and schedule. These design standards generally apply to all disciplines on all SNL/NM projects. Architectural and engineering design must be both functional and cost-effective. Facility design must be tailored to fit its intended function, while emphasizing low-maintenance, energy-efficient, and energy-conscious design. Design facilities that can be maintained easily, with readily accessible equipment areas, low maintenance, and quality systems. To promote an orderly and efficient appearance, architectural features of new facilities must complement and enhance the existing architecture at the site. As an Architectural and Engineering (A/E) professional, you must advise the Project Manager when this approach is prohibitively expensive. You are encouraged to use professional judgment and ingenuity to produce a coordinated interdisciplinary design that is cost-effective, easily contractible or buildable, high-performing, aesthetically pleasing, and compliant with applicable building codes. Close coordination and development of civil, landscape, structural, architectural

  19. Productivity of Veterans Health Administration laboratories: a College of American Pathologists Laboratory Management Index Program (LMIP) study.

    PubMed

    Valenstein, Paul N; Wang, Edward; O'Donohue, Tom

    2003-12-01

    The Veterans Health Administration (VA) operates the largest integrated laboratory network in the United States. To assess whether the unique characteristics of VA laboratories impact efficiency of operations, we compared the productivity of VA and non-VA facilities. Financial and activity data were prospectively collected from 124 VA and 131 non-VA laboratories enrolled in the College of American Pathologists Laboratory Management Index Program (LMIP) during 2002. In addition, secular trends in 5 productivity ratios were calculated for VA and non-VA laboratories enrolled in LMIP from 1997 through 2002. Veterans Health Administration and non-VA facilities did not differ significantly in size. Inpatients accounted for a lower percentage of testing at VA facilities than non-VA facilities (21.7% vs 37.3%; P <.001). Technical staff at the median VA facility were paid more than at non-VA facilities (28.11/h dollars vs 22.60/h dollars, salaries plus benefits; P <.001), VA laboratories employed a smaller percentage of nontechnical staff (30.0% vs 41.9%; P <.001), and workers at VA laboratories worked less time per hour paid (85.5% vs 88.5%; P <.001). However, labor productivity was significantly higher at VA than at non-VA facilities (30 448 test results/total full-time equivalent (FTE)/y vs 19 260 results/total FTE; P <.001), resulting in lower labor expense per on-site test at VA sites than at non-VA sites (1.79 dollars/result vs 2.08 dollars/result; P <.001). Veterans Health Administration laboratories paid less per test for consumables (P =.003), depreciation, and maintenance than their non-VA counterparts (all P <.001), resulting in lower overall cost per on-site test result (2.64 dollars vs 3.40 dollars; P <.001). Cost per referred (sent-out) test did not differ significantly between the 2 groups. Analysis of 6-year trends showed significant increases in both VA (P <.001) and non-VA (P =.02) labor productivity (on-site tests/total FTE). Expenses at VA laboratories

  20. Adoption of Lean Principles in a High-Volume Molecular Diagnostic Microbiology Laboratory

    PubMed Central

    Mitchell, P. Shawn; Mandrekar, Jayawant N.

    2014-01-01

    Clinical laboratories are constantly facing challenges to do more with less, enhance quality, improve test turnaround time, and reduce operational expenses. Experience with adopting and applying lean concepts and tools used extensively in the manufacturing industry is described for a high-volume clinical molecular microbiology laboratory, illustrating how operational success and benefits can be achieved. PMID:24829247

  1. 10. Floor Layout of Thermal Hydraulics Laboratory, from The Thermal ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Floor Layout of Thermal Hydraulics Laboratory, from The Thermal Hydraulics Laboratory at Hanford. General Electric Company, Hanford Atomic Products Operation, Richland, Washington, 1961. - D-Reactor Complex, Deaeration Plant-Refrigeration Buildings, Area 100-D, Richland, Benton County, WA

  2. Space station operations management

    NASA Technical Reports Server (NTRS)

    Cannon, Kathleen V.

    1989-01-01

    Space Station Freedom operations management concepts must be responsive to the unique challenges presented by the permanently manned international laboratory. Space Station Freedom will be assembled over a three year period where the operational environment will change as significant capability plateaus are reached. First Element Launch, Man-Tended Capability, and Permanent Manned Capability, represent milestones in operational capability that is increasing toward mature operations capability. Operations management concepts are being developed to accomodate the varying operational capabilities during assembly, as well as the mature operational environment. This paper describes operations management concepts designed to accomodate the uniqueness of Space Station Freedoom, utilizing tools and processes that seek to control operations costs.

  3. Effective utilization of clinical laboratories.

    PubMed

    Murphy, J; Henry, J B

    1978-11-01

    Effective utilization of clinical laboratories requires that underutilization, overutilization, and malutilization be appreciated and eliminated or reduced. Optimal patient care service, although subjective to a major extent, is reflected in terms of outcome and cost. Increased per diem charges, reduced hospital stay, and increased laboratory workload over the past decade all require each laboratory to examine its internal operations to achieve economy and efficiency as well as maximal effectiveness. Increased research and development, an active managerial role on the part of pathologists, internal self-assessment, and an aggressive response to sophisticated scientific and clinical laboratory data base requirements are not only desirable but essential. The importance of undergraduate and graduate medical education in laboratory medicine to insure understanding as well as effective utilization is stressed. The costs and limitations as well as the accuracy, precision, sensitivity, specificity, and pitfalls of measurements and examinations must also be fully appreciated. Medical malpractice and defensive medicine and the use of critical values, emergency and routine services, and an active clinical role by the pathologist are of the utmost value in assuring effective utilization of the laboratory. A model for the optimal use of the laboratory including economy and efficiency has been achieved in the blood bank in regard to optimal hemotherapy for elective surgery, assuring superior patient care in a cost effective and safe manner.

  4. Operating characteristic analysis of a 400 mH class HTS DC reactor in connection with a laboratory scale LCC type HVDC system

    NASA Astrophysics Data System (ADS)

    Kim, Sung-Kyu; Kim, Kwangmin; Park, Minwon; Yu, In-Keun; Lee, Sangjin

    2015-11-01

    High temperature superconducting (HTS) devices are being developed due to their advantages. Most line commutated converter based high voltage direct current (HVDC) transmission systems for long-distance transmission require large inductance of DC reactor; however, generally, copper-based reactors cause a lot of electrical losses during the system operation. This is driving researchers to develop a new type of DC reactor using HTS wire. The authors have developed a 400 mH class HTS DC reactor and a laboratory scale test-bed for line-commutated converter type HVDC system and applied the HTS DC reactor to the HVDC system to investigate their operating characteristics. The 400 mH class HTS DC reactor is designed using a toroid type magnet. The HVDC system is designed in the form of a mono-pole system with thyristor-based 12-pulse power converters. In this paper, the investigation results of the HTS DC reactor in connection with the HVDC system are described. The operating characteristics of the HTS DC reactor are analyzed under various operating conditions of the system. Through the results, applicability of an HTS DC reactor in an HVDC system is discussed in detail.

  5. Safety in the Chemical Laboratory

    ERIC Educational Resources Information Center

    Steere, Norman V., Ed.

    1975-01-01

    The National Fire Protection Association has proposed national standards dealing with laboratory operations, ventilation, chemical handling and storage, compressed gases, fire prevention, and emergency procedures. The standards are likely to be used as guidelines by insurance companies, and governmental agencies that award grants and contracts for…

  6. First two operational years of the electron-beam ion trap charge breeder at the National Superconducting Cyclotron Laboratory

    NASA Astrophysics Data System (ADS)

    Lapierre, A.; Bollen, G.; Crisp, D.; Krause, S. W.; Linhardt, L. E.; Lund, K.; Nash, S.; Rencsok, R.; Ringle, R.; Schwarz, S.; Steiner, M.; Sumithrarachchi, C.; Summers, T.; Villari, A. C. C.; Williams, S. J.; Zhao, Q.

    2018-05-01

    The electron-beam ion trap (EBIT) charge breeder of the ReA post-accelerator, located at the National Superconducting Cyclotron Laboratory (Michigan State University), started on-line operation in September 2015. Since then, the EBIT has delivered many pilot beams of stable isotopes and several rare-isotope beams. An operating aspect of the ReA EBIT is the breeding of high charge states to reach high reaccelerated beam energies. Efficiencies in single charge states of more than 20% were measured with K39 15 + , Rb85 27 + , K47 17 + , and Ar34 15 + . Producing high charge states demands long breeding times. This reduces the ejection frequency and, hence, increases the number of ions ejected per pulse. Another operating aspect is the ability to spread the distribution in time of the ejected ion pulses to lower the instantaneous rate delivered to experiments. Pulse widths were stretched from a natural 25 μ s up to ˜70 ms . This publication reviews the progress of the ReA EBIT system over the years and presents the results of charge-breeding efficiency measurements and pulse-stretching tests obtained with stable- and rare-isotope beams. Studies performed with high sensitivity to identify and quantify stable-isotope contaminants from the EBIT are also presented, along with a novel method for purifying beams.

  7. ATES/heat pump simulations performed with ATESSS code

    NASA Astrophysics Data System (ADS)

    Vail, L. W.

    1989-01-01

    Modifications to the Aquifer Thermal Energy Storage System Simulator (ATESSS) allow simulation of aquifer thermal energy storage (ATES)/heat pump systems. The heat pump algorithm requires a coefficient of performance (COP) relationship of the form: COP = COP sub base + alpha (T sub ref minus T sub base). Initial applications of the modified ATES code to synthetic building load data for two sizes of buildings in two U.S. cities showed insignificant performance advantage of a series ATES heat pump system over a conventional groundwater heat pump system. The addition of algorithms for a cooling tower and solar array improved performance slightly. Small values of alpha in the COP relationship are the principal reason for the limited improvement in system performance. Future studies at Pacific Northwest Laboratory (PNL) are planned to investigate methods to increase system performance using alternative system configurations and operations scenarios.

  8. The Department of Energy`s Remedial Action Assessment System (RAAS): Decision support tools for performing streamlined feasibility studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, M.K.

    1994-06-01

    The United States Department of Energy (DOE) faces the major task of cleaning up hundreds of waste sites across the nation, which will require completion of a large number of remedial investigation/feasibility studies (RI/FSs). The intent of each RI/FS is to characterize the waste problems and environmental conditions at the operable unit level, segment the remediation problem into manageable medium-specific and contaminant-specific pieces, define corresponding remediation objectives, and identify remedial response actions to satisfy those objectives. The RI/FS team can then identify combinations of remediation technologies that will meet the remediation objectives. Finally, the team must evaluate these remedial alternativesmore » in terms of effectiveness, implementability, cost, and acceptability. The Remedial Action Assessment System (RAAS) is being developed by Pacific Northwest Laboratory (PNL) to support DOE in this effort.« less

  9. Site Environmental Report for Calendar Year 2005. DOE Operations at The Boeing Company, Santa Susana Field Laboratory, Area IV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2006-09-30

    This annual report describes the environmental monitoring programs related to the Department of Energy’s (DOE) activities at the Santa Susana Field Laboratory (SSFL) facility located in Ventura County, California during 2005. Part of the SSFL facility, known as Area IV, had been used for DOE’s activities since the 1950s. A broad range of energy related research and development (R&D) projects, including nuclear technologies projects, was conducted at the site. All the nuclear R&D operations in Area IV ceased in 1988. Current efforts are directed toward decontamination and decommissioning (D&D) of the former nuclear facilities and closure of facilities used formore » liquid metal research.« less

  10. Laboratory Directed Research and Development FY-15 Annual Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pillai, Rekha Sukamar

    The Laboratory Directed Research and Development (LDRD) Program at Idaho National Laboratory (INL) reports its status to the U.S. Department of Energy (DOE) by March of each year. The program operates under the authority of DOE Order 413.2B, “Laboratory Directed Research and Development” (April 19, 2006), which establishes DOE’s requirements for the program while providing the laboratory director broad flexibility for program implementation. LDRD funds are obtained through a charge to all INL programs. This report includes summaries of all INL LDRD research activities supported during Fiscal Year (FY) 2015.

  11. The Tanzania experience: clinical laboratory testing harmonization and equipment standardization at different levels of a tiered health laboratory system.

    PubMed

    Massambu, Charles; Mwangi, Christina

    2009-06-01

    The rapid scale-up of the care and treatment programs in Tanzania during the preceding 4 years has greatly increased the demand for quality laboratory services for diagnosis of HIV and monitoring patients during antiretroviral therapy. Laboratory services were not in a position to cope with this demand owing to poor infrastructure, lack of human resources, erratic and/or lack of reagent supply and commodities, and slow manual technologies. With the limited human resources in the laboratory and the need for scaling up the care and treatment program, it became necessary to install automated equipment and train personnel for the increased volume of testing and new tests across all laboratory levels. With the numerous partners procuring equipment, the possibility of a multitude of equipment platforms with attendant challenges for procurement of reagents, maintenance of equipment, and quality assurance arose. Tanzania, therefore, had to harmonize laboratory tests and standardize laboratory equipment at different levels of the laboratory network. The process of harmonization of tests and standardization of equipment included assessment of laboratories, review of guidelines, development of a national laboratory operational plan, and stakeholder advocacy. This document outlines this process.

  12. Site Environmental Report for Calendar Year 2007. DOE Operations at The Boeing Company, Santa Susana Field Laboratory, Area IV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Ning; Rutherford, Phil; Lenox, Art

    2008-09-30

    This Annual Site Environmental Report (ASER) for 2007 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of Boeing’s Santa Susana Field Laboratory (SSFL). The Energy Technology Engineering Center (ETEC), a government-owned, company-operated test facility, was located in Area IV. The operations in Area IV included development, fabrication, and disassembly of nuclear reactors, reactor fuel, and other radioactive materials. Other activities in the area involved the operation of large-scale liquid metal facilities that were used for testing non-nuclear liquid metal fast breeder components. All nuclear work was terminated in 1988; all subsequentmore » radiological work has been directed toward decontamination and decommissioning (D&D) of the former nuclear facilities and their associated sites. In May 2007, the D&D operations in Area IV were suspended until DOE completes the SSFL Area IV Environmental Impact Statement (EIS). The environmental monitoring programs were continued throughout the year. Results of the radiological monitoring program for the calendar year 2007 continue to indicate that there are no significant releases of radioactive material from Area IV of SSFL. All potential exposure pathways are sampled and/or monitored, including air, soil, surface water, groundwater, direct radiation, transfer of property (land, structures, waste), and recycling. All radioactive wastes are processed for disposal at DOE disposal sites and/or other licensed sites approved by DOE for radioactive waste disposal. No liquid radioactive wastes were released into the environment in 2007.« less

  13. Pure neuritic leprosy: Resolving diagnostic issues in acid fast bacilli (AFB)-negative nerve biopsies: A single centre experience from South India.

    PubMed

    Hui, Monalisa; Uppin, Megha S; Challa, Sundaram; Meena, A K; Kaul, Subhash

    2015-01-01

    Demonstration of lepra bacilli is essential for definite or unequivocal diagnosis of pure neuritic leprosy (PNL) on nerve biopsy. However, nerves always do not show bacilli owing to the changes of previous therapy or due to low bacillary load in tuberculoid forms. In absence of granuloma or lepra bacilli, other morphologic changes in endoneurium and perineurium can be of help in making a probable diagnosis of PNL and treating the patient with multidrug therapy. Forty-six biopsies of PNL were retrospectively reviewed and histologic findings were compared with 25 biopsies of non leprosy neuropathies (NLN) including vasculitic neuropathy and chronic inflammatory demyelinating polyneuropathy (CIDP). The distribution of endoneurial infiltrate and fibrosis, perineurial thickening, and myelin abnormalities were compared between PNL and NLN biopsies and analyzed by Chi-square test. Out of 46 PNL casses, 24 (52.17 %) biopsies were negative for acid fast bacilli (AFB). In these cases, the features which favor a diagnosis of AFB-negative PNL were endoneurial infiltrate (51.1%), endoneurial fibrosis (54.2%), perineurial thickening (70.8%), and reduced number of myelinated nerve fibers (75%). Nerve biopsy is an efficient tool to diagnose PNL and differentiate it from other causes of NLN. In absence of AFB, the diagnosis of PNL is challenging. In this article, we have satisfactorily evaluated the various hisopthological features and found that endoneurial inflammation, dense fibrosis, and reduction in the number of myelinated nerve fibers are strong supportive indicators of PNL regardless of AFB positivity.

  14. Retrograde Intrarenal Surgery versus Percutaneous Lithotripsy to Treat Renal Stones 2-3 cm in Diameter

    PubMed Central

    Zengin, Kursad; Tanik, Serhat; Sener, Nevzat Can; Albayrak, Sebahattin; Tuygun, Can; Bakirtas, Hasan; Imamoglu, M. Abdurrahim; Gurdal, Mesut

    2015-01-01

    Objective. Retrograde intrarenal surgery (RIRS) performed using a flexible ureterorenoscope marked the beginning of a new era in urology. Today, even staghorn stones are successfully treated via RIRS. The recommended treatment for larger stones is percutaneous nephrolithotomy (PNL). However, the question of whether PNL or RIRS should be the first-line treatment option for larger stones remains controversial. In this study, we contribute to the debate by comparing the success and complication rates of PNL and RIRS that were used to treat renal pelvis stones 2-3 cm in diameter. Materials and Methods. The medical records of 154 patients (74 PNL, 80 RIRS) were retrospectively evaluated. PNL patients were placed in Group 1 and RIRS patients in Group 2. Results. The complete stone-free rates were 95.5% in the PNL group and 80.6% in the RIRS group 1 month postoperatively (P = 0.061). The respective complication rates (evaluated using the Clavien system) were 13.5% and 8.8% (P = 0.520). Conclusions. RIRS affords a comparable success rate, causes fewer complications than PNL, and seems to be a promising alternative to PNL when larger stones are to be treated. Prospective randomized controlled trials are needed to confirm these findings. PMID:25821828

  15. Minimizing radiation exposure during percutaneous nephrolithotomy.

    PubMed

    Chen, T T; Preminger, G M; Lipkin, M E

    2015-12-01

    Given the recent trends in growing per capita radiation dose from medical sources, there have been increasing concerns over patient radiation exposure. Patients with kidney stones undergoing percutaneous nephrolithotomy (PNL) are at particular risk for high radiation exposure. There exist several risk factors for increased radiation exposure during PNL which include high Body Mass Index, multiple access tracts, and increased stone burden. We herein review recent trends in radiation exposure, radiation exposure during PNL to both patients and urologists, and various approaches to reduce radiation exposure. We discuss incorporating the principles of As Low As reasonably Achievable (ALARA) into clinical practice and review imaging techniques such as ultrasound and air contrast to guide PNL access. Alternative surgical techniques and approaches to reducing radiation exposure, including retrograde intra-renal surgery, retrograde nephrostomy, endoscopic-guided PNL, and minimally invasive PNL, are also highlighted. It is important for urologists to be aware of these concepts and techniques when treating stone patients with PNL. The discussions outlined will assist urologists in providing patient counseling and high quality of care.

  16. Direct pelvic access percutaneous nephrolithotomy in management of ectopic kidney stone: a case report and literature review.

    PubMed

    Mehmet, Rifaioglu Murat; Rustu, Yalcinkaya Fatih; Hanefi, Bayarogullari; Mursel, Davarci; Fusun, Aydogan; Mehmet, Inci

    2013-01-01

    Percutaneous nephrolithotomy (PNL) is an effective procedure for the treatment of patients with large or complex stones. PNL is challenging in anomalous kidneys, certain patients, such as those with renal ectopia. It is unable to undergo PNL in conventional technique safely in these cases. We presented a case report of laparoscopic-assisted PNL via direct pelvic puncture in a pelvic kidney stone and discussed previous published literature. A 49-year-old man presented with right lower quadrant pain and hematuria. Intravenous pyelography and three-dimensional computerized tomography revealed an opaque 2.7 × 1.7 cm pelvis renalis stone in a right side ectopic pelvic kidney with grade III hydronephrosis. Laparoscopic-assisted tubeless PNL was performed to remove the calculus. Laparoscopic-assisted PNL as a minimally invasive therapy in ectopic kidney has many advantages. Our case showed that, in pelvic ectopic kidney with pelvic stones greater than 1.5 cm in size, laparoscopic-assisted PNL via direct pelvis puncture is a safe and effective technique.

  17. Burner Rig Laboratory

    NASA Image and Video Library

    2015-05-12

    The Fuel Burner Rig is a test laboratory at NASA Glenn, which subjects new jet engine materials, treated with protective coatings, to the hostile, high temperature, high velocity environment found inside aircraft turbine engines. These samples face 200-mile per hour flames to simulate the temperatures of aircraft engines in flight. The rig can also simulate aircraft carrier and dusty desert operations where salt and sand can greatly reduce engine life and performance.

  18. 40 CFR 160.81 - Standard operating procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 25 2013-07-01 2013-07-01 false Standard operating procedures. 160.81... GOOD LABORATORY PRACTICE STANDARDS Testing Facilities Operation § 160.81 Standard operating procedures. (a) A testing facility shall have standard operating procedures in writing setting forth study...

  19. 40 CFR 160.81 - Standard operating procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 24 2014-07-01 2014-07-01 false Standard operating procedures. 160.81... GOOD LABORATORY PRACTICE STANDARDS Testing Facilities Operation § 160.81 Standard operating procedures. (a) A testing facility shall have standard operating procedures in writing setting forth study...

  20. 40 CFR 160.81 - Standard operating procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 25 2012-07-01 2012-07-01 false Standard operating procedures. 160.81... GOOD LABORATORY PRACTICE STANDARDS Testing Facilities Operation § 160.81 Standard operating procedures. (a) A testing facility shall have standard operating procedures in writing setting forth study...

  1. Payload Operations

    NASA Technical Reports Server (NTRS)

    Cissom, R. D.; Melton, T. L.; Schneider, M. P.; Lapenta, C. C.

    1999-01-01

    The objective of this paper is to provide the future ISS scientist and/or engineer a sense of what ISS payload operations are expected to be. This paper uses a real-time operations scenario to convey this message. The real-time operations scenario begins at the initiation of payload operations and runs through post run experiment analysis. In developing this scenario, it is assumed that the ISS payload operations flight and ground capabilities are fully available for use by the payload user community. Emphasis is placed on telescience operations whose main objective is to enable researchers to utilize experiment hardware onboard the International Space Station as if it were located in their terrestrial laboratory. An overview of the Payload Operations Integration Center (POIC) systems and user ground system options is included to provide an understanding of the systems and interfaces users will utilize to perform payload operations. Detailed information regarding POIC capabilities can be found in the POIC Capabilities Document, SSP 50304.

  2. Do English NHS Microbiology laboratories offer adequate services for the diagnosis of UTI in children? Healthcare Quality Improvement Partnership (HQIP) Audit of Standard Operational Procedures.

    PubMed

    McNulty, Cliodna A M; Verlander, Neville Q; Moore, Philippa C L; Larcombe, James; Dudley, Jan; Banerjee, Jaydip; Jadresic, Lyda

    2015-09-01

    The National Institute of Care Excellence (NICE) 2007 guidance CG54, on urinary tract infection (UTI) in children, states that clinicians should use urgent microscopy and culture as the preferred method for diagnosing UTI in the hospital setting for severe illness in children under 3 years old and from the GP setting in children under 3 years old with intermediate risk of severe illness. NICE also recommends that all 'infants and children with atypical UTI (including non-Escherichia coli infections) should have renal imaging after a first infection'. We surveyed all microbiology laboratories in England with Clinical Pathology Accreditation to determine standard operating procedures (SOPs) for urgent microscopy, culture and reporting of children's urine and to ascertain whether the SOPs facilitate compliance with NICE guidance. We undertook a computer search in six microbiology laboratories in south-west England to determine urine submissions and urine reports in children under 3 years. Seventy-three per cent of laboratories (110/150) participated. Enterobacteriaceae that were not E. coli were reported only as coliforms (rather than non-E. coli coliforms) by 61% (67/110) of laboratories. Eighty-eight per cent of laboratories (97/110) provided urgent microscopy for hospital and 54% for general practice (GP) paediatric urines; 61% of laboratories (confidence interval 52-70%) cultured 1 μl volume of urine, which equates to one colony if the bacterial load is 106 c.f.u. l(-1). Only 22% (24/110) of laboratories reported non-E. coli coliforms and provided urgent microscopy for both hospital and GP childhood urines; only three laboratories also cultured a 5 μl volume of urine. Only one of six laboratories in our submission audit had a significant increase in urine submissions and urines reported from children less than 3 years old between the predicted pre-2007 level in the absence of guidance and the 2008 level following publication of the NICE guidance. Less than a

  3. Overview of EPA Pesticide Laboratories and Methods

    EPA Pesticide Factsheets

    EPA operates two pesticide laboratories that provide a variety of technical services to the Agency, other federal and state agencies, tribal groups and other organizations.The labs develop methods and procedures.

  4. Site Environmental Report for 2010 Sandia National Laboratories, California.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larsen, Barbara L.

    2011-06-01

    Sandia National Laboratories, California (SNL/CA) is a government-owned/contractor-operated laboratory. Sandia Corporation, a Lockheed Martin Company, manages and operates the laboratory for the Department of Energy's National Nuclear Security Administration (NNSA). The NNSA Sandia Site Office administers the contract and oversees contractor operations at the site. This Site Environmental Report for 2010 was prepared in accordance with DOE Order 231.1A (DOE 2004a). The report provides a summary of environmental monitoring information and compliance activities that occurred at SNL/CA during calendar year 2010. General site and environmental program information is also included. The Site Environmental Report is divided into ten chapters. Chaptermore » 1, the Executive Summary, highlights compliance and monitoring results obtained in 2010. Chapter 2 provides a brief introduction to SNL/CA and the existing environment found on site. Chapter 3 summarizes SNL/CA's compliance activities with the major environmental requirements applicable to site operations. Chapter 4 presents information on environmental management, performance measures, and environmental programs. Chapter 5 presents the results of monitoring and surveillance activities in 2010. Chapter 6 discusses quality assurance. Chapters 7 through 9 provide supporting information for the report and Chapter 10 is the report distribution list.« less

  5. PaR-PaR Laboratory Automation Platform

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Linshiz, G; Stawski, N; Poust, S

    2013-05-01

    Labor-intensive multistep biological tasks, such as the construction and cloning of DNA molecules, are prime candidates for laboratory automation. Flexible and biology-friendly operation of robotic equipment is key to its successful integration in biological laboratories, and the efforts required to operate a robot must be much smaller than the alternative manual lab work. To achieve these goals, a simple high-level biology-friendly robot programming language is needed. We have developed and experimentally validated such a language: Programming a Robot (PaR-PaR). The syntax and compiler for the language are based on computer science principles and a deep understanding of biological workflows. PaR-PaRmore » allows researchers to use liquid-handling robots effectively, enabling experiments that would not have been considered previously. After minimal training, a biologist can independently write complicated protocols for a robot within an hour. Adoption of PaR-PaR as a standard cross-platform language would enable hand-written or software-generated robotic protocols to be shared across laboratories.« less

  6. PaR-PaR laboratory automation platform.

    PubMed

    Linshiz, Gregory; Stawski, Nina; Poust, Sean; Bi, Changhao; Keasling, Jay D; Hillson, Nathan J

    2013-05-17

    Labor-intensive multistep biological tasks, such as the construction and cloning of DNA molecules, are prime candidates for laboratory automation. Flexible and biology-friendly operation of robotic equipment is key to its successful integration in biological laboratories, and the efforts required to operate a robot must be much smaller than the alternative manual lab work. To achieve these goals, a simple high-level biology-friendly robot programming language is needed. We have developed and experimentally validated such a language: Programming a Robot (PaR-PaR). The syntax and compiler for the language are based on computer science principles and a deep understanding of biological workflows. PaR-PaR allows researchers to use liquid-handling robots effectively, enabling experiments that would not have been considered previously. After minimal training, a biologist can independently write complicated protocols for a robot within an hour. Adoption of PaR-PaR as a standard cross-platform language would enable hand-written or software-generated robotic protocols to be shared across laboratories.

  7. Laboratory evaluation of detectors of explosives' effluents

    DOT National Transportation Integrated Search

    1972-11-30

    This document contains the classification, technical description and laboratory evaluation of five commercial detectors for explosives' effluents. It includes an outline of operating principles, test and evaluation procedures. The evaluation is based...

  8. Nuclear criticality safety staff training and qualifications at Los Alamos National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Monahan, S.P.; McLaughlin, T.P.

    1997-05-01

    Operations involving significant quantities of fissile material have been conducted at Los Alamos National Laboratory continuously since 1943. Until the advent of the Laboratory`s Nuclear Criticality Safety Committee (NCSC) in 1957, line management had sole responsibility for controlling criticality risks. From 1957 until 1961, the NCSC was the Laboratory body which promulgated policy guidance as well as some technical guidance for specific operations. In 1961 the Laboratory created the position of Nuclear Criticality Safety Office (in addition to the NCSC). In 1980, Laboratory management moved the Criticality Safety Officer (and one other LACEF staff member who, by that time, wasmore » also working nearly full-time on criticality safety issues) into the Health Division office. Later that same year the Criticality Safety Group, H-6 (at that time) was created within H-Division, and staffed by these two individuals. The training and education of these individuals in the art of criticality safety was almost entirely self-regulated, depending heavily on technical interactions between each other, as well as NCSC, LACEF, operations, other facility, and broader criticality safety community personnel. Although the Los Alamos criticality safety group has grown both in size and formality of operations since 1980, the basic philosophy that a criticality specialist must be developed through mentoring and self motivation remains the same. Formally, this philosophy has been captured in an internal policy, document ``Conduct of Business in the Nuclear Criticality Safety Group.`` There are no short cuts or substitutes in the development of a criticality safety specialist. A person must have a self-motivated personality, excellent communications skills, a thorough understanding of the principals of neutron physics, a safety-conscious and helpful attitude, a good perspective of real risk, as well as a detailed understanding of process operations and credible upsets.« less

  9. Tritium laboratory with multiple purposes at NIPNE Magurele Romania

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matei, L.; Postolache, C.

    2008-07-15

    The Tritium Laboratory from NIPNE (Romania)) is part of Radioisotope Research and Production Center. The Tritium Laboratory has been in operation since 1960, and carries out R and D activities involving tritium sources in gaseous, liquids and solid state, provides specialized service to CANDU NPP Cernavoda (Romania)), and provides tritium assay services to internal and external customers. The paper presents the activities and perspectives of Tritium Laboratory and its performances in accordance with Quality System Management. (authors)

  10. 222-S Laboratory Quality Assurance Plan. Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meznarich, H.K.

    1995-07-31

    This Quality Assurance Plan provides,quality assurance (QA) guidance, regulatory QA requirements (e.g., 10 CFR 830.120), and quality control (QC) specifications for analytical service. This document follows the U.S Department of Energy (DOE) issued Hanford Analytical Services Quality Assurance Plan (HASQAP). In addition, this document meets the objectives of the Quality Assurance Program provided in the WHC-CM-4-2, Section 2.1. Quality assurance elements required in the Guidelines and Specifications for Preparing Quality Assurance Program Plans (QAMS-004) and Interim Guidelines and Specifications for Preparing Quality Assurance Project Plans (QAMS-005) from the US Environmental Protection Agency (EPA) are covered throughout this document. A qualitymore » assurance index is provided in the Appendix A. This document also provides and/or identifies the procedural information that governs laboratory operations. The personnel of the 222-S Laboratory and the Standards Laboratory including managers, analysts, QA/QC staff, auditors, and support staff shall use this document as guidance and instructions for their operational and quality assurance activities. Other organizations that conduct activities described in this document for the 222-S Laboratory shall follow this QA/QC document.« less

  11. Environmental Measurements Laboratory fiscal year 1998: Accomplishments and technical activities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erickson, M.D.

    1999-01-01

    The Environmental Measurements Laboratory (EML) is government-owned, government-operated, and programmatically under the DOE Office of Environmental Management. The Laboratory is administered by the Chicago Operations Office. EML provides program management, technical assistance and data quality assurance for measurements of radiation and radioactivity relating to environmental restoration, global nuclear nonproliferation, and other priority issues for the Department of Energy, as well as for other government, national, and international organizations. This report presents the technical activities and accomplishments of EML for Fiscal Year 1998.

  12. Adoption of lean principles in a high-volume molecular diagnostic microbiology laboratory.

    PubMed

    Mitchell, P Shawn; Mandrekar, Jayawant N; Yao, Joseph D C

    2014-07-01

    Clinical laboratories are constantly facing challenges to do more with less, enhance quality, improve test turnaround time, and reduce operational expenses. Experience with adopting and applying lean concepts and tools used extensively in the manufacturing industry is described for a high-volume clinical molecular microbiology laboratory, illustrating how operational success and benefits can be achieved. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  13. 48 CFR 970.1504-1-3 - Special considerations: Laboratory management and operation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... appropriate for laboratories (science/technology and support) is rated at less than the target level of... established for the life of the contract. It will be established at time of award, as part of the extend...

  14. 48 CFR 970.1504-1-3 - Special considerations: Laboratory management and operation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... appropriate for laboratories (science/technology and support) is rated at less than the target level of... established for the life of the contract. It will be established at time of award, as part of the extend...

  15. 48 CFR 970.1504-1-3 - Special considerations: Laboratory management and operation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... appropriate for laboratories (science/technology and support) is rated at less than the target level of... established for the life of the contract. It will be established at time of award, as part of the extend...

  16. 48 CFR 970.1504-1-3 - Special considerations: Laboratory management and operation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... appropriate for laboratories (science/technology and support) is rated at less than the target level of... established for the life of the contract. It will be established at time of award, as part of the extend...

  17. [Current biosafety in clinical laboratories in Japan: report of questionnaires' data obtained from clinical laboratory personnel in Japan].

    PubMed

    Goto, Mieko; Yamashita, Tomonari; Misawa, Shigeki; Komori, Toshiaki; Okuzumi, Katsuko; Takahashi, Takashi

    2007-01-01

    To determine the status of biosafety in clinical laboratories in Japan, we conducted a survey using questionnaires on the biosafety of laboratory personnel in 2004. We obtained data from 431 hospitals (response: 59.5%). Respondents were 301 institutions (70%) having biological safety cabinets (BSCs). BSCs were held in 78% of microbiological laboratories, 7.9% of genetic laboratories, 2.7% of histopathological laboratories, and 1% or less at other laboratories. A clean bench in examination rooms for acid-fast bacilli was applied at 20 hospitals. We found 28 cases of possible laboratory-associated tuberculosis infection, 25 of which were associated with lack of BSC. Other risk factors were immature skills and insufficiently skilled eguipment operation. The frequency of rupture accidents during specimen centrifugation was 67% in dealing with blood and 9.7% in collecting acid-fast bacilli. Half or more accidents were related to inadequate sample tube materials. Technologists were shown to be working on blood collection in many hospitals (75%), and 1,534 events of self-inflicted needle puncture developed in the last 5 years. These results suggest that biosafety systems are woefully lacking or inadequate in clinical laboratories in Japan and must be established at the earliest possible opportunity.

  18. Federal Security Laboratory Governance Panels: Observations and Recommendations

    DTIC Science & Technology

    2013-01-01

    operates under a sole-source, cost-plus-fixed-fee contract administered by the U.S. Navy’s Naval Sea Systems Command. There are currently 14 UARCs, 13... system of research organizations that support science and technology for U.S. national security. Within this system , the Departments of Defense, Energy...and Homeland Security support about 80 laboratories that focus predominantly on national security matters. These laboratories have different

  19. NASA Mars Science Laboratory Rover

    NASA Technical Reports Server (NTRS)

    Olson, Tim

    2017-01-01

    Since August 2012, the NASA Mars Science Laboratory (MSL) rover Curiosity has been operating on the Martian surface. The primary goal of the MSL mission is to assess whether Mars ever had an environment suitable for life. MSL Science Team member Dr. Tim Olson will provide an overview of the rover's capabilities and the major findings from the mission so far. He will also share some of his experiences of what it is like to operate Curiosity's science cameras and explore Mars as part of a large team of scientists and engineers.

  20. The pre-audit assessment: A homework assignment for auditors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marschman, S.C.

    1993-02-01

    The role of the quality assurance audit is evolving from compliance verification to a much broader assessment of programmatic and management performance. In the past, audits were poorly understood and caused fear and trepidation. Auditees turned an audit into a cat-and-mouse game using coverup strategies and decoy discrepancies. These games were meant to ``give the auditors what they want, namely a few findings that could later be easily corrected. At Pacific Northwest Laboratory (PNL), I observed auditing become a spectator sport. Matching a compliance-oriented auditor against a crafty group of scientists provided hours of entertainment. As a program manager, itmore » was clear these games were neither productive useful nor cost effective. Fortunately, over the past few years several concepts embraced by ``total quality management` have begun to emerge at PNL. These concepts are being adopted by most successful organizations, and based on these concepts new tools and ideas are emerging to help organizations improve productivity and quality. Successful organizations have been and are continuing to develop management strategies that rely on participative approaches to their operations. These approaches encourage the empowerment of organization staff at all levels, with the goal of instilling ownership of quality in every staff member. As management philosophies are changing, so are the responsibilities and expectations of managers. Managers everywhere are experimenting with new tools to help them improve their operations and competitiveness. As the quality audit evolves, managers and other customers of the audit process have developed expectations for the auditing process that never existed in years past. These expectations have added complexity to the audit process. It is no longer adequate to prepare a checklist, perform the audit, and document the results. When viewed as a tool for verifying performance, a quality audit becomes more than a compliance checklist.« less

  1. The pre-audit assessment: A homework assignment for auditors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marschman, S.C.

    1993-02-01

    The role of the quality assurance audit is evolving from compliance verification to a much broader assessment of programmatic and management performance. In the past, audits were poorly understood and caused fear and trepidation. Auditees turned an audit into a cat-and-mouse game using coverup strategies and decoy discrepancies. These games were meant to give the auditors what they want, namely a few findings that could later be easily corrected. At Pacific Northwest Laboratory (PNL), I observed auditing become a spectator sport. Matching a compliance-oriented auditor against a crafty group of scientists provided hours of entertainment. As a program manager, itmore » was clear these games were neither productive useful nor cost effective. Fortunately, over the past few years several concepts embraced by total quality management' have begun to emerge at PNL. These concepts are being adopted by most successful organizations, and based on these concepts new tools and ideas are emerging to help organizations improve productivity and quality. Successful organizations have been and are continuing to develop management strategies that rely on participative approaches to their operations. These approaches encourage the empowerment of organization staff at all levels, with the goal of instilling ownership of quality in every staff member. As management philosophies are changing, so are the responsibilities and expectations of managers. Managers everywhere are experimenting with new tools to help them improve their operations and competitiveness. As the quality audit evolves, managers and other customers of the audit process have developed expectations for the auditing process that never existed in years past. These expectations have added complexity to the audit process. It is no longer adequate to prepare a checklist, perform the audit, and document the results. When viewed as a tool for verifying performance, a quality audit becomes more than a compliance checklist.« less

  2. Percutaneous nephrolithotomy in pediatric patients: is computerized tomography a must?

    PubMed

    Gedik, Abdullah; Tutus, Ali; Kayan, Devrim; Yılmaz, Yakup; Bircan, Kamuran

    2011-02-01

    The aim of this study was to retrospectively evaluate the results of pediatric percutaneous nephrolithotomy (PNL) cases, and discuss the results and necessity of non-contrast computerized tomography (CT) in these cases. In all, 48 pediatric patients who underwent PNL were retrospectively evaluated. Before PNL, either intravenous urography or CT was performed. In all patients, we evaluated the PNL time, scopy time with stone burden, and complications. During the PNL procedure, we switched to open surgery in two cases: in one because of renal pelvis perforation and in the other because of transcolonic access. In one patient who was scheduled to undergo PNL, we performed open surgery, primarily because we detected a retrorenal colon with CT. The stone burden in 45 patients who underwent PNL was 445 ± 225 mm(2), the PNL time was 51 ± 23 min, and the scopy time was 6.1 ± 2.7 min. We removed nephrostomy tubes 1-4 days after the procedure. In two patients, 24 h after removal of nephrostomy tubes, we inserted double J stents because of prolonged urine extravasation from the tract. In all, 34 of the 45 patients were stone-free, 5 patients had clinically insignificant stone fragments, and 6 patients had residual stones. PNL is a safe and effective method in the treatment of pediatric patients with kidney stones. Clinical experience is the most important factor in obtaining stone-free results. CT should be performed in all pediatric patients in order to prevent colon perforation.

  3. Pure neuritic leprosy: Resolving diagnostic issues in acid fast bacilli (AFB)-negative nerve biopsies: A single centre experience from South India

    PubMed Central

    Hui, Monalisa; Uppin, Megha S.; Challa, Sundaram; Meena, A. K.; Kaul, Subhash

    2015-01-01

    Background and Purpose: Demonstration of lepra bacilli is essential for definite or unequivocal diagnosis of pure neuritic leprosy (PNL) on nerve biopsy. However, nerves always do not show bacilli owing to the changes of previous therapy or due to low bacillary load in tuberculoid forms. In absence of granuloma or lepra bacilli, other morphologic changes in endoneurium and perineurium can be of help in making a probable diagnosis of PNL and treating the patient with multidrug therapy. Materials and Methods: Forty-six biopsies of PNL were retrospectively reviewed and histologic findings were compared with 25 biopsies of non leprosy neuropathies (NLN) including vasculitic neuropathy and chronic inflammatory demyelinating polyneuropathy (CIDP). The distribution of endoneurial infiltrate and fibrosis, perineurial thickening, and myelin abnormalities were compared between PNL and NLN biopsies and analyzed by Chi-square test. Results: Out of 46 PNL casses, 24 (52.17 %) biopsies were negative for acid fast bacilli (AFB). In these cases, the features which favor a diagnosis of AFB-negative PNL were endoneurial infiltrate (51.1%), endoneurial fibrosis (54.2%), perineurial thickening (70.8%), and reduced number of myelinated nerve fibers (75%). Interpretation and Conclusion: Nerve biopsy is an efficient tool to diagnose PNL and differentiate it from other causes of NLN. In absence of AFB, the diagnosis of PNL is challenging. In this article, we have satisfactorily evaluated the various hisopthological features and found that endoneurial inflammation, dense fibrosis, and reduction in the number of myelinated nerve fibers are strong supportive indicators of PNL regardless of AFB positivity. PMID:26425006

  4. Nuclear deformation in the laboratory frame

    NASA Astrophysics Data System (ADS)

    Gilbreth, C. N.; Alhassid, Y.; Bertsch, G. F.

    2018-01-01

    We develop a formalism for calculating the distribution of the axial quadrupole operator in the laboratory frame within the rotationally invariant framework of the configuration-interaction shell model. The calculation is carried out using a finite-temperature auxiliary-field quantum Monte Carlo method. We apply this formalism to isotope chains of even-mass samarium and neodymium nuclei and show that the quadrupole distribution provides a model-independent signature of nuclear deformation. Two technical advances are described that greatly facilitate the calculations. The first is to exploit the rotational invariance of the underlying Hamiltonian to reduce the statistical fluctuations in the Monte Carlo calculations. The second is to determine quadruple invariants from the distribution of the axial quadrupole operator in the laboratory frame. This allows us to extract effective values of the intrinsic quadrupole shape parameters without invoking an intrinsic frame or a mean-field approximation.

  5. Laboratory challenges conducting international clinical research in resource-limited settings.

    PubMed

    Fitzgibbon, Joseph E; Wallis, Carole L

    2014-01-01

    There are many challenges to performing clinical research in resource-limited settings. Here, we discuss several of the most common laboratory issues that must be addressed. These include issues relating to organization and personnel, laboratory facilities and equipment, standard operating procedures, external quality assurance, shipping, laboratory capacity, and data management. Although much progress has been made, innovative ways of addressing some of these issues are still very much needed.

  6. Framework for leadership and training of Biosafety Level 4 laboratory workers.

    PubMed

    Le Duc, James W; Anderson, Kevin; Bloom, Marshall E; Estep, James E; Feldmann, Heinz; Geisbert, Joan B; Geisbert, Thomas W; Hensley, Lisa; Holbrook, Michael; Jahrling, Peter B; Ksiazek, Thomas G; Korch, George; Patterson, Jean; Skvorak, John P; Weingartl, Hana

    2008-11-01

    Construction of several new Biosafety Level 4 (BSL-4) laboratories and expansion of existing operations have created an increased international demand for well-trained staff and facility leaders. Directors of most North American BSL-4 laboratories met and agreed upon a framework for leadership and training of biocontainment research and operations staff. They agreed on essential preparation and training that includes theoretical consideration of biocontainment principles, practical hands-on training, and mentored on-the-job experiences relevant to positional responsibilities as essential preparation before a person's independent access to a BSL-4 facility. They also agreed that the BSL-4 laboratory director is the key person most responsible for ensuring that staff members are appropriately prepared for BSL-4 operations. Although standardized certification of training does not formally exist, the directors agreed that facility-specific, time-limited documentation to recognize specific skills and experiences of trained persons is needed.

  7. Clinical efficacy and safety of transcatheter embolization for vascular complications after percutaneous nephrolithotomy.

    PubMed

    Poyraz, Necdet; Balasar, Mehmet; Gökmen, İbrahim Erdem; Koç, Osman; Sönmez, Mehmet Giray; Aydın, Arif; Göger, Yunus Emre; Öztürk, Ahmet

    2017-12-01

    Percutaneous nephrolithotomy (PNL) is the preferred procedure for safe and effective surgical treatment of kidney stones. Hemorrhage is the most serious complication of PNL, resulting from pseudoaneurysm (PA) or arteriovenous fistula (AVF), and can usually be controlled with conservative treatment. To evaluate endovascular treatments and outcomes of vascular complications observed after PNL. We retrospectively reviewed data on 19 patients who underwent renal embolization due to post-PNL renal artery bleeding between March 2005 and September 2016. Embolization materials included embolization coils and glue. The incidence of post-PNL vascular complications and their endovascular treatments, outcomes, and the follow-up data were analyzed. Nineteen (1.1%) of 1,609 patients (mean age: 44.9 years, range: 19-75 years) underwent angiography and subsequent transcatheter embolization to control bleeding. The mean time to onset of hemorrhage was 7.2 days after PNL (range: 3-18 days). The PNL entry site was the lower calyx in 15 patients, the middle calyx in 3, and the upper calyx in 1. PA, AVF, and PA plus AVF occurred in 14, 5, and 3 of the 19 renal angiography patients, respectively. Embolization of the affected vessels was successful in all 19 patients. The embolization materials of coil, glue, and coil plus glue were used in 16, 3, and 2 patients, respectively. Severe hematuria is a rare complication of PNL and can be successfully treated with transcatheter embolization.

  8. Percutaneous nephrolithotomy is highly efficient and safe in infants and children under 3 years of age.

    PubMed

    Guven, Selcuk; Istanbulluoglu, Okan; Ozturk, Ahmet; Ozturk, Bulent; Piskin, Mesut; Cicek, Tufan; Kilinc, Mehmet; Ozkardes, Hakan; Arslan, Mehmet

    2010-01-01

    We aimed to evaluate the efficacy and safety of percutaneous nephrolithotomy (PNL) in infants and small children (12-36 months). The PNL applications conducted in children <3 years of age in two centers were evaluated. Whereas pediatric PNL instrumentation was used in the first center, adult-size instrumentation was utilized in the second center. The complications were given according to the modified Clavien classification system. The mean age of the patients was 22.76 months (5-36 months) and the mean body weight was 11.51 kg (6-15 kg). In twelve renal units, pediatric instrumentation was used and among these, two had miniperc. In the other eight renal units, adult-size instrumentation was employed. Except for the patient with complex renal stones, all patients were stone free after the intervention and none required a conversion to open surgery. There were grade 1-2 complications in 3 patients. The postoperative hemoglobin drop was greater in the children who underwent PNL with adult-size instrumentation. In this young age group, in addition to standard PNL, simultaneous bilateral PNL, tubeless PNL and in urgent cases of renal failure, urgent PNL, are safe and effective treatment modalities provided patients are selected properly and the surgeon performing the procedure has the necessary experience. Copyright © 2010 S. Karger AG, Basel.

  9. Percutaneous nephrolithotomy in ectopically located kidneys and in patients with musculoskeletal deformities.

    PubMed

    Srivastava, A; Gupta, P; Chaturvedi, S; Singh, P; Kapoor, R; Dubey, D; Kumar, A

    2010-01-01

    To assess the feasibility, safety and results of percutaneous nephrolithotomy (PNL) in ectopically located kidneys and in patients with musculoskeletal deformities. Thirteen such patients underwent PNL between June 2005 and May 2008. Mean stone size was 27.4 mm (16-37 mm). Six patients had severe kyphoscoliosis, 2 patients each had achondroplasia, cross-fused ectopia and pelvic ectopic kidney, and 1 patient had thoracic kidney. All had a preoperative CT scan of the abdomen. Preoperative ultrasound- or CT-guided percutaneous nephrostomy (PCN) was done in 10 patients. Three patients underwent laparoscopic-assisted PNL. All underwent standard PNL. The stone-free rate, complication rate and need for secondary intervention were evaluated. PNL was successfully completed in all. A second ultrasound-guided intraoperative puncture was required in 2 patients. Re-look PNL was required in 1 patient and the same patient later required shock wave lithotripsy for complete stone clearance. The remaining 12 patients (92.3%) were rendered stone-free in a single sitting. PNL is a feasible and effective modality in anomalous kidneys. Preoperative planning with CT and image-guided PCN is helpful in these situations. Laparoscopic-assisted PNL can be safely performed in patients where access to a renal collecting system by fluoroscopy or image-guided assistance (ultrasound or CT scan) is not possible. Copyright (c) 2010 S. Karger AG, Basel.

  10. Preliminary testing of turbulence and radionuclide transport modeling in deep ocean environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Onishi, Y.; Dummuller, D.C.; Trent, D.S.

    Pacific Northwest Laboratory (PNL) performed a study for the US Environmental Protection Agency's Office of Radiation Programs to (1) identify candidate models for regional modeling of low-level waste ocean disposal sites in the mid-Atlantic ocean; (2) evaluate mathematical representation of the model's eddy viscosity/dispersion coefficients; and (3) evaluate the adequacy of the k-{epsilon} turbulence model and the feasibility of one of the candidate models, TEMPEST{copyright}/FLESCOT{copyright}, to deep-ocean applications on a preliminary basis. PNL identified the TEMPEST{copyright}/FLESCOT{copyright}, FLOWER, Blumberg's, and RMA 10 models as appropriate candidates for the regional radionuclide modeling. Among these models, TEMPEST/FLESCOT is currently the only model thatmore » solves distributions of flow, turbulence (with the k-{epsilon} model), salinity, water temperature, sediment, dissolved contaminants, and sediment-sorbed contaminants. Solving the Navier-Stokes equations using higher order correlations is not practical for regional modeling because of the prohibitive computational requirements; therefore, the turbulence modeling is a more practical approach. PNL applied the three-dimensional code, TEMPEST{copyright}/FLESCOT{copyright} with the k-{epsilon} model, to a very simple, hypothetical, two-dimensional, deep-ocean case, producing at least qualitatively appropriate results. However, more detailed testing should be performed for the further testing of the code. 46 refs., 39 figs., 6 tabs.« less

  11. ONR Tidal Flats DRI: Planning Joint Modeling and Field Exercises

    DTIC Science & Technology

    2007-01-01

    ONR Tidal Flats DRI: Planning Joint Modeling and Field Exercises Lyle Hibler Battelle/Marine Research Operations 1529 West Sequim Bay Road...West Sequim Bay Road Sequim , WA 98382 Phone: (360) 681-4591 Fax: (360) 681-4598 Email: adam.maxwell@pnl.gov Award Number: N000140710694...PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Battelle/Marine Research Operations,1529 West Sequim Bay Road, Sequim ,WA,98382 8. PERFORMING ORGANIZATION

  12. Description of the Spacecraft Control Laboratory Experiment (SCOLE) facility

    NASA Technical Reports Server (NTRS)

    Williams, Jeffrey P.; Rallo, Rosemary A.

    1987-01-01

    A laboratory facility for the study of control laws for large flexible spacecraft is described. The facility fulfills the requirements of the Spacecraft Control Laboratory Experiment (SCOLE) design challenge for a laboratory experiment, which will allow slew maneuvers and pointing operations. The structural apparatus is described in detail sufficient for modelling purposes. The sensor and actuator types and characteristics are described so that identification and control algorithms may be designed. The control implementation computer and real-time subroutines are also described.

  13. Description of the Spacecraft Control Laboratory Experiment (SCOLE) facility

    NASA Technical Reports Server (NTRS)

    Williams, Jeffrey P.; Rallo, Rosemary A.

    1987-01-01

    A laboratory facility for the study of control laws for large flexible spacecraft is described. The facility fulfills the requirements of the Spacecraft Control Laboratory Experiment (SCOLE) design challenge for laboratory experiments, which will allow slew maneuvers and pointing operations. The structural apparatus is described in detail sufficient for modelling purposes. The sensor and actuator types and characteristics are described so that identification and control algorithms may be designed. The control implementation computer and real-time subroutines are also described.

  14. 1. VIEW OF A PORTION OF THE HYDRIDE PROCESSING LABORATORY. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. VIEW OF A PORTION OF THE HYDRIDE PROCESSING LABORATORY. OPERATIONS IN THE GLOVE BOX IN THE BACKGROUND OF THE PHOTOGRAPH INCLUDED HYDRIDING OF PLUTONIUM AND HYDRIDE SEPARATION. IN THE FOREGROUND, THE VACUUM MONITOR CONTROL PANEL MEASURED TEMPERATURES WITHIN THE GLOVEBOX. THE CENTER CONTROL PANEL REGULATED THE FURNACE INSIDE THE GLOVE BOX USED IN THE HYDRIDING PROCESSES. THIS EQUIPMENT WAS ESSENTIAL TO THE HYDRIDING PROCESS, AS WELL AS OTHER GLOVE BOX OPERATIONS. - Rocky Flats Plant, Plutonium Laboratory, North-central section of industrial area at 79 Drive, Golden, Jefferson County, CO

  15. A Comprehensive Laboratory Animal Facility Pandemic Response Plan

    PubMed Central

    Roble, Gordon S; Lingenhol, Naomi M; Baker, Bryan; Wilkerson, Amy; Tolwani, Ravi J

    2010-01-01

    The potential of a severe influenza pandemic necessitates the development of an organized, rational plan for continued laboratory animal facility operation without compromise of the welfare of animals. A comprehensive laboratory animal program pandemic response plan was integrated into a university-wide plan. Preparation involved input from all levels of organizational hierarchy including the IACUC. Many contingencies and operational scenarios were considered based on the severity and duration of the influenza pandemic. Trigger points for systematic action steps were based on the World Health Organization's phase alert criteria. One extreme scenario requires hibernation of research operations and maintenance of reduced numbers of laboratory animal colonies for a period of up to 6 mo. This plan includes active recruitment and cross-training of volunteers for essential personnel positions, protective measures for employee and family health, logistical arrangements for delivery and storage of food and bedding, the removal of waste, and the potential for euthanasia. Strategies such as encouraging and subsidizing cryopreservation of unique strains were undertaken to protect valuable research assets and intellectual property. Elements of this plan were put into practice after escalation of the pandemic alerts due to influenza A (H1N1) in April 2009. PMID:20858365

  16. NASA's Planetary Aeolian Laboratory: Status and Update

    NASA Astrophysics Data System (ADS)

    Williams, D. A.; Smith, J. K.

    2017-05-01

    This presentation provides a status update on the operational capabilities and funding plans by NASA for the Planetary Aeolian Laboratory located at NASA Ames Research Center, including details for those proposing future wind tunnel experiments.

  17. Laboratory medicine in France. A jeopardized situation.

    PubMed

    Valdiguié, P M; de Graeve, J S; Guerre, J P

    1997-11-06

    The expenses for health care in France have risen considerably during the present decade, ranking third after USA and Canada in the Western world. In spite of the very low cost of laboratory medicine (2.4% of the total expenditure in 1995), clinical laboratories have undergone a severe squeeze, due to two limiting factors; a decrease in the ordering of laboratory tests from private physicians and a reduction in the total expenses for laboratory services from the Social Security. Consequently, there has been unemployment of technical and secretarial staff and severe restriction in investment for buying new equipment. However, hospital laboratories will manage to assume their challenge in developing robotics, automation, molecular pathology techniques and expert systems. Private laboratories, in spite of their efforts to follow the technological advances in automation, will survive thanks to consolidation of regional networks that operate in a cooperative rather than competitive mode. Therefore, the challenge will be not in the adaptation of clinical laboratories, but in the limitation of overspending at the national level and in modification of the behaviour of irresponsible citizens accustomed to spending freely on health care services.

  18. Effect of at-the-source noise reduction on performance and weights of a tilt-rotor aircraft

    NASA Technical Reports Server (NTRS)

    Gibs, J.; Stepniewski, W. Z.; Spencer, R.

    1975-01-01

    Reduction of far-field acoustic signature through modification of basic design parameters (tip speed, number of blades, disc loading and rotor blade area) was examined, using a tilt-rotor flight research aircraft as a baseline configuration. Of those design parameters, tip speed appeared as the most important. Next, preliminary design of two aircraft was performed, postulating the following reduction of noise level from that of the baseline machine, at 500 feet from the spot of OGE hover. In one aircraft, the PNL was lowered by 10 PNdB and in the other, OASPL decreased by 10 dB. The resulting weight and performance penalties were examined. Then, PNL and EPNL aspects of terminal operation were compared for the baseline and quieter aircraft.

  19. Stationary Engineering Laboratory Manual--2.

    ERIC Educational Resources Information Center

    Steingress, Frederick M.; Frost, Harold J.

    The Stationary Engineering Laboratory Manual 2 was designed for vocational/technical high school students who have received instruction in the basics of stationary engineering. It was developed for students who will be operating a live plant and who will be responsible for supplying steam for heating, cooking, and baking. Each lesson in the manual…

  20. The laboratory of the 1990s—Planning for total automation

    PubMed Central

    Brunner, Linda A.

    1992-01-01

    The analytical laboratory of the 1990s must be able to meet and accommodate the rapid evolution of modern-day technology. One such area is laboratory automation. Total automation may be seen as the coupling of computerized sample tracking, electronic documentation and data reduction with automated sample handling, preparation and analysis, resulting in a complete analytical procedure with minimal human involvement. Requirements may vary from one laboratory or facility to another, so the automation has to be flexible enough to cover a wide range of applications, and yet fit into specific niches depending on individual needs. Total automation must be planned for, well in advance, if the endeavour is to be a success. Space, laboratory layout, proper equipment, and the availability and access to necessary utilities must be taken into account. Adequate training and experience of the personnel working with the technology must also be ensured. In addition, responsibilities of installation, programming maintenance and operation have to be addressed. Proper time management and the efficient implementation and use of total automation are also crucial to successful operations. This paper provides insights into laboratory organization and requirements, as well as discussing the management issues that must be faced when automating laboratory procedures. PMID:18924925

  1. DSP-Based Hands-On Laboratory Experiments for Photovoltaic Power Systems

    ERIC Educational Resources Information Center

    Muoka, Polycarp I.; Haque, Md. Enamul; Gargoom, Ameen; Negnetvitsky, Michael

    2015-01-01

    This paper presents a new photovoltaic (PV) power systems laboratory module that was developed to experimentally reinforce students' understanding of design principles, operation, and control of photovoltaic power conversion systems. The laboratory module is project-based and is designed to support a renewable energy course. By using MATLAB…

  2. Establishing Ebola Virus Disease (EVD) diagnostics using GeneXpert technology at a mobile laboratory in Liberia: Impact on outbreak response, case management and laboratory systems strengthening

    PubMed Central

    Condell, Orla; Wasunna, Christine; Kpaka, Jonathan; Zwizwai, Ruth; Nuha, Mahmood; Fallah, Mosoka; Freeman, Maxwell; Harris, Victoria; Miller, Mark; Baller, April; Massaquoi, Moses; Katawera, Victoria; Saindon, John; Bemah, Philip; Hamblion, Esther; Castle, Evelyn; Williams, Desmond; Gasasira, Alex; Nyenswah, Tolbert

    2018-01-01

    The 2014–16 Ebola Virus Disease (EVD) outbreak in West Africa highlighted the necessity for readily available, accurate and rapid diagnostics. The magnitude of the outbreak and the re-emergence of clusters of EVD cases following the declaration of interrupted transmission in Liberia, reinforced the need for sustained diagnostics to support surveillance and emergency preparedness. We describe implementation of the Xpert Ebola Assay, a rapid molecular diagnostic test run on the GeneXpert platform, at a mobile laboratory in Liberia and the subsequent impact on EVD outbreak response, case management and laboratory system strengthening. During the period of operation, site coordination, management and operational capacity was supported through a successful collaboration between Ministry of Health (MoH), World Health Organization (WHO) and international partners. A team of Liberian laboratory technicians were trained to conduct EVD diagnostics and the laboratory had capacity to test 64–100 blood specimens per day. Establishment of the laboratory significantly increased the daily testing capacity for EVD in Liberia, from 180 to 250 specimens at a time when the effectiveness of the surveillance system was threatened by insufficient diagnostic capacity. During the 18 months of operation, the laboratory tested a total of 9,063 blood specimens, including 21 EVD positives from six confirmed cases during two outbreaks. Following clearance of the significant backlog of untested EVD specimens in November 2015, a new cluster of EVD cases was detected at the laboratory. Collaboration between surveillance and laboratory coordination teams during this and a later outbreak in March 2016, facilitated timely and targeted response interventions. Specimens taken from cases during both outbreaks were analysed at the laboratory with results informing clinical management of patients and discharge decisions. The GeneXpert platform is easy to use, has relatively low running costs and can

  3. Establishing Ebola Virus Disease (EVD) diagnostics using GeneXpert technology at a mobile laboratory in Liberia: Impact on outbreak response, case management and laboratory systems strengthening.

    PubMed

    Raftery, Philomena; Condell, Orla; Wasunna, Christine; Kpaka, Jonathan; Zwizwai, Ruth; Nuha, Mahmood; Fallah, Mosoka; Freeman, Maxwell; Harris, Victoria; Miller, Mark; Baller, April; Massaquoi, Moses; Katawera, Victoria; Saindon, John; Bemah, Philip; Hamblion, Esther; Castle, Evelyn; Williams, Desmond; Gasasira, Alex; Nyenswah, Tolbert

    2018-01-01

    The 2014-16 Ebola Virus Disease (EVD) outbreak in West Africa highlighted the necessity for readily available, accurate and rapid diagnostics. The magnitude of the outbreak and the re-emergence of clusters of EVD cases following the declaration of interrupted transmission in Liberia, reinforced the need for sustained diagnostics to support surveillance and emergency preparedness. We describe implementation of the Xpert Ebola Assay, a rapid molecular diagnostic test run on the GeneXpert platform, at a mobile laboratory in Liberia and the subsequent impact on EVD outbreak response, case management and laboratory system strengthening. During the period of operation, site coordination, management and operational capacity was supported through a successful collaboration between Ministry of Health (MoH), World Health Organization (WHO) and international partners. A team of Liberian laboratory technicians were trained to conduct EVD diagnostics and the laboratory had capacity to test 64-100 blood specimens per day. Establishment of the laboratory significantly increased the daily testing capacity for EVD in Liberia, from 180 to 250 specimens at a time when the effectiveness of the surveillance system was threatened by insufficient diagnostic capacity. During the 18 months of operation, the laboratory tested a total of 9,063 blood specimens, including 21 EVD positives from six confirmed cases during two outbreaks. Following clearance of the significant backlog of untested EVD specimens in November 2015, a new cluster of EVD cases was detected at the laboratory. Collaboration between surveillance and laboratory coordination teams during this and a later outbreak in March 2016, facilitated timely and targeted response interventions. Specimens taken from cases during both outbreaks were analysed at the laboratory with results informing clinical management of patients and discharge decisions. The GeneXpert platform is easy to use, has relatively low running costs and can be

  4. Integrating research into operational practice

    PubMed Central

    Ross, Alastair

    2015-01-01

    Research and development can be classified into three categories: technology adoption, technology extension, and knowledge and technology creation. In general, technology adoption is embedded in operational forensic science laboratory practice but the latter two categories require partnerships with industry and/or academia both to conduct the research and implement the outcomes. In a 2012 survey, Australian and New Zealand forensic science laboratories identified a number of ‘roadblocks’ to undertaking research and operationalizing research outcomes. These included insufficient time and funding, a lack of in-house research experience and the absence of a tangible research culture. Allied to this is that, increasingly, forensic science research is conducted in a ‘commercial in confidence’ environment and the outcomes are not readily or cost-effectively available to be integrated into operational forensic science laboratories. The paper is predominantly reflective of the current situation in Australia and New Zealand PMID:26101286

  5. STRUCTURED LEARNING AND TRAINING ENVIRONMENTS--A PREPARATION LABORATORY FOR ADVANCED MAMMALIAN PHYSIOLOGY.

    ERIC Educational Resources Information Center

    FIEL, NICHOLAS J.; JOHNSTON, RAYMOND F.

    A PREPARATION LABORATORY WAS DESIGNED TO FAMILIARIZE STUDENTS IN ADVANCED MAMMALIAN PHYSIOLOGY WITH LABORATORY SKILLS AND TECHNIQUES AND THUS SHORTEN THE TIME THEY SPEND IN SETTING UP ACTUAL EXPERIMENTS. THE LABORATORY LASTS 30 MINUTES, IS FLEXIBLE AND SIMPLE OF OPERATION, AND DOES NOT REQUIRE A PROFESSOR'S PRESENCE. THE BASIC TRAINING UNIT IS THE…

  6. NASA Laboratory Astrophysics Workshop 2006 Introductory Remarks

    NASA Technical Reports Server (NTRS)

    Hasan, Hashima

    2006-01-01

    NASA Laboratory Astrophysics Workshop 2006, is the fourth in a series of workshops held at four year intervals, to assess the laboratory needs of NASA's astrophysics missions - past, current and future. Investigators who need laboratory data to interpret their observations from space missions, theorists and modelers, experimentalists who produce the data, and scientists who compile databases have an opportunity to exchange ideas and understand each other's needs and limitations. The multi-wavelength character of these workshops allows cross-fertilization of ideas, raises awareness in the scientific community of the rapid advances in other fields, and the challenges it faces in prioritizing its laboratory needs in a tight budget environment. Currently, we are in the golden age of Space Astronomy, with three of NASA s Great Observatories, Hubble Space Telescope (HST), Chandra X-Ray Observatory (CXO), and Spitzer Space Telescope (SST), in operation and providing astronomers and opportunity to perform synergistic observations. In addition, the Far Ultraviolet Spectroscopic Explorer (FUSE), XMM-Newton, HETE-2, Galaxy Evolution Explorer (GALEX), INTEGRAL and Wilkinson Microwave Anisotropy Probe (WMAP), are operating in an extended phase, while Swift and Suzaku are in their prime phase of operations. The wealth of data from these missions is stretching the Laboratory Astrophysics program to its limits. Missions in the future, which also need such data include the James Webb Space Telescope (JWST), Space Interferometry Mission (SIM), Constellation-X (Con-X), Herschel, and Planck. The interpretation of spectroscopic data from these missions requires knowledge of atomic and molecular parameters such as transition probabilities, f-values, oscillator strengths, excitation cross sections, collision strengths, which have either to be measured in the laboratory by simulating space plasma and interactions therein, or by theoretical calculations and modeling. Once the laboratory

  7. Do English NHS Microbiology laboratories offer adequate services for the diagnosis of UTI in children? Healthcare Quality Improvement Partnership (HQIP) Audit of Standard Operational Procedures

    PubMed Central

    Verlander, Neville Q.; Moore, Philippa C. L.; Larcombe, James; Dudley, Jan; Banerjee, Jaydip; Jadresic, Lyda

    2015-01-01

    The National Institute of Care Excellence (NICE) 2007 guidance CG54, on urinary tract infection (UTI) in children, states that clinicians should use urgent microscopy and culture as the preferred method for diagnosing UTI in the hospital setting for severe illness in children under 3 years old and from the GP setting in children under 3 years old with intermediate risk of severe illness. NICE also recommends that all ‘infants and children with atypical UTI (including non-Escherichia coli infections) should have renal imaging after a first infection’. We surveyed all microbiology laboratories in England with Clinical Pathology Accreditation to determine standard operating procedures (SOPs) for urgent microscopy, culture and reporting of children's urine and to ascertain whether the SOPs facilitate compliance with NICE guidance. We undertook a computer search in six microbiology laboratories in south-west England to determine urine submissions and urine reports in children under 3 years. Seventy-three per cent of laboratories (110/150) participated. Enterobacteriaceae that were not E. coli were reported only as coliforms (rather than non-E. coli coliforms) by 61 % (67/110) of laboratories. Eighty-eight per cent of laboratories (97/110) provided urgent microscopy for hospital and 54 % for general practice (GP) paediatric urines; 61 % of laboratories (confidence interval 52–70 %) cultured 1 μl volume of urine, which equates to one colony if the bacterial load is 106 c.f.u. l− 1. Only 22 % (24/110) of laboratories reported non-E. coli coliforms and provided urgent microscopy for both hospital and GP childhood urines; only three laboratories also cultured a 5 μl volume of urine. Only one of six laboratories in our submission audit had a significant increase in urine submissions and urines reported from children less than 3 years old between the predicted pre-2007 level in the absence of guidance and the 2008 level following publication

  8. Albuquerque Seismological Laboratory--50 years of global seismology

    USGS Publications Warehouse

    Hutt, C.R.; Peterson, Jon; Gee, Lind; Derr, John; Ringler, Adam; Wilson, David

    2011-01-01

    The U.S. Geological Survey Albuquerque Seismological Laboratory is about 15 miles southeast of Albuquerque on the Pueblo of Isleta, adjacent to Kirtland Air Force Base. The Albuquerque Seismological Laboratory supports the Global Seismographic Network Program and the Advanced National Seismic System through the installation, operation, and maintenance of seismic stations around the world and serves as the premier seismological instrumentation test facility for the U.S. Government.

  9. Remedial Action Assessment System (RAAS): A computer-based methodology for conducting feasibility studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buelt, J.L.; Stottlemyre, J.A.; White, M.K.

    1991-09-01

    Because of the great complexity and number of potential waste sites facing the US Department of Energy (DOE) for potential cleanup, the DOE is supporting the development of a computer-based methodology to streamline the remedial investigations/feasibility study process required for DOE operable units. DOE operable units are generally more complex in nature because of the existence of multiple waste sites within many of the operable units and the presence of mixed radioactive and hazardous chemical wastes. Consequently, Pacific Northwest Laboratory (PNL) is developing the Remedial Action Assessment System (RAAS), which is aimed at screening, linking, and evaluating establishment technology processmore » options in support of conducting feasibility studies under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). It is also intended to do the same in support of corrective measures studies requires by the Resource Conservation and Recovery Act (RCRA). This paper presents the characteristics of two RAAS prototypes currently being developed. These include the RAAS Technology Information System, which accesses information on technologies in a graphical and tabular manner, and the main RAAS methodology, which screens, links, and evaluates remedial technologies. 4 refs., 3 figs., 1 tab.« less

  10. Remedial Action Assessment System (RAAS): A computer-based methodology for conducting feasibility studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buelt, J.L.; Stottlemyre, J.A.; White, M.K.

    1991-02-01

    Because of the great complexity and number of potential waste sites facing the US Department of Energy (DOE) for potential cleanup, the DOE is supporting the development of a computer-based methodology to streamline the remedial investigation/feasibility study process required for DOE operable units. DOE operable units are generally more complex in nature because of the existence of multiple waste sites within many of the operable units and the presence of mixed radioactive and hazardous chemical wastes. Consequently, Pacific Northwest Laboratory (PNL) is developing the Remedial Action Assessment System (RAAS), which is aimed at screening, linking, and evaluating established technology processmore » options in support of conducting feasibility studies under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). It is also intended to do the same in support of corrective measures studies required by the Resource Conservation and Recovery Act (RCRA). This paper presents the characteristics of two RAAS prototypes currently being developed. These include the RAAS Technology Information System, which accesses information on technologies in a graphical and tabular manner, and the main RAAS methodology, which screens, links, and evaluates remedial technologies. 4 refs., 3 figs., 1 tab.« less

  11. Whole Genome Sequencing and Multiplex qPCR Methods to Identify Campylobacter jejuni Encoding cst-II or cst-III Sialyltransferase

    PubMed Central

    Neal-McKinney, Jason M.; Liu, Kun C.; Jinneman, Karen C.; Wu, Wen-Hsin; Rice, Daniel H.

    2018-01-01

    Campylobacter jejuni causes more than 2 million cases of gastroenteritis annually in the United States, and is also linked to the autoimmune sequelae Guillan–Barre syndrome (GBS). GBS often results in flaccid paralysis, as the myelin sheaths of nerve cells are degraded by the adaptive immune response. Certain strains of C. jejuni modify their lipooligosaccharide (LOS) with the addition of neuraminic acid, resulting in LOS moieties that are structurally similar to gangliosides present on nerve cells. This can trigger GBS in a susceptible host, as antibodies generated against C. jejuni can cross-react with gangliosides, leading to demyelination of nerves and a loss of signal transduction. The goal of this study was to develop a quantitative PCR (qPCR) method and use whole genome sequencing data to detect the Campylobacter sialyltransferase (cst) genes responsible for the addition of neuraminic acid to LOS. The qPCR method was used to screen a library of 89 C. jejuni field samples collected by the Food and Drug Administration Pacific Northwest Lab (PNL) as well as clinical isolates transferred to PNL. In silico analysis was used to screen 827 C. jejuni genomes in the FDA GenomeTrakr SRA database. The results indicate that a majority of C. jejuni strains could produce LOS with ganglioside mimicry, as 43.8% of PNL isolates and 46.9% of the GenomeTrakr isolates lacked the cst genes. The methods described in this study can be used by public health laboratories to rapidly determine whether a C. jejuni isolate has the potential to induce GBS. Based on these results, a majority of C. jejuni in the PNL collection and submitted to GenomeTrakr have the potential to produce LOS that mimics human gangliosides. PMID:29615986

  12. Whole Genome Sequencing and Multiplex qPCR Methods to Identify Campylobacter jejuni Encoding cst-II or cst-III Sialyltransferase.

    PubMed

    Neal-McKinney, Jason M; Liu, Kun C; Jinneman, Karen C; Wu, Wen-Hsin; Rice, Daniel H

    2018-01-01

    Campylobacter jejuni causes more than 2 million cases of gastroenteritis annually in the United States, and is also linked to the autoimmune sequelae Guillan-Barre syndrome (GBS). GBS often results in flaccid paralysis, as the myelin sheaths of nerve cells are degraded by the adaptive immune response. Certain strains of C. jejuni modify their lipooligosaccharide (LOS) with the addition of neuraminic acid, resulting in LOS moieties that are structurally similar to gangliosides present on nerve cells. This can trigger GBS in a susceptible host, as antibodies generated against C. jejuni can cross-react with gangliosides, leading to demyelination of nerves and a loss of signal transduction. The goal of this study was to develop a quantitative PCR (qPCR) method and use whole genome sequencing data to detect the Campylobacter sialyltransferase ( cst ) genes responsible for the addition of neuraminic acid to LOS. The qPCR method was used to screen a library of 89 C. jejuni field samples collected by the Food and Drug Administration Pacific Northwest Lab (PNL) as well as clinical isolates transferred to PNL. In silico analysis was used to screen 827 C. jejuni genomes in the FDA GenomeTrakr SRA database. The results indicate that a majority of C. jejuni strains could produce LOS with ganglioside mimicry, as 43.8% of PNL isolates and 46.9% of the GenomeTrakr isolates lacked the cst genes. The methods described in this study can be used by public health laboratories to rapidly determine whether a C. jejuni isolate has the potential to induce GBS. Based on these results, a majority of C. jejuni in the PNL collection and submitted to GenomeTrakr have the potential to produce LOS that mimics human gangliosides.

  13. The need for econometric research in laboratory animal operations.

    PubMed

    Baker, David G; Kearney, Michael T

    2015-06-01

    The scarcity of research funding can affect animal facilities in various ways. These effects can be evaluated by examining the allocation of financial resources in animal facilities, which can be facilitated by the use of mathematical and statistical methods to analyze economic problems, a discipline known as econometrics. The authors applied econometrics to study whether increasing per diem charges had a negative effect on the number of days of animal care purchased by animal users. They surveyed animal numbers and per diem charges at 20 research institutions and found that demand for large animals decreased as per diem charges increased. The authors discuss some of the challenges involved in their study and encourage research institutions to carry out more robust econometric studies of this and other economic questions facing laboratory animal research.

  14. [Biosafety in laboratories concerning exposure to biological agents].

    PubMed

    Vonesch, N; Tomao, P; Di Renzi, S; Vita, S; Signorini, S

    2006-01-01

    Laboratory workers are exposed to a variety of potential occupational health hazards including those deriving from infectious materials and cultures, radiations, toxic and flammable chemicals, as well as mechanical and electrical hazard. Although all of them are significant, this paper will focus on biological hazards present in clinical and research laboratories. In fact, in spite of numerous publications, guidelines and regulations, laboratory workers are still subject to infections acquired in the course of their researches. This paper describes some aspects that include good microbiological practices (GMPs), appropriate containment equipment, practices and operational procedures to minimize workers' risk of injury or illness.

  15. Development and characterization of a high-reliability, extended-lifetime H- ion source

    NASA Astrophysics Data System (ADS)

    Becerra, Gabriel; Barrows, Preston; Sherman, Joseph

    2015-11-01

    Phoenix Nuclear Labs (PNL) has designed and constructed a long-lifetime, negative hydrogen (H-) ion source, in partnership with Fermilab for an ion beam injector servicing future Intensity Frontier particle accelerators. The specifications for the low-energy beam transport (LEBT) section are 5-10 mA of continuous H- ion current at 30 keV with <0.2 π-mm-mrad emittance. Existing ion sources at Fermilab rely on plasma-facing electrodes, limiting their lifetime to a few hundred hours, while requiring relatively high gas loads on downstream components. PNL's design features an electron cyclotron resonance (ECR) microwave plasma driver which has been extensively developed in positive ion source systems, having demonstrated 1000+ hours of operation and >99% continuous uptime at PNL. Positive ions and hyperthermal neutrals drift toward a low-work-function surface, where a fraction is converted into H- hydrogen ions, which are subsequently extracted into a low-energy beam using electrostatic lenses. A magnetic filter preferentially removes high-energy electrons emitted by the source plasma, in order to mitigate H- ion destruction via electron-impact detachment. The design of the source subsystems and preliminary diagnostic results will be presented.

  16. Percutaneous nephrolithotomy for the treatment of radiolucent renal stones in children: is it different opaque stone treatment?

    PubMed

    Adanur, Şenol; Ziypak, Tevfik; Sancaktutar, Ahmet Ali; Tepeler, Abdülkadir; Reşorlu, Berkan; Söylemez, Haluk; Dağgülli, Mansur; Özbey, İsa; Unsal, Ali

    2014-02-01

    We aimed to evaluate the effectiveness of percutaneous nephrolithotomy (PNL), stone-free rates, and related complications in children with radiolucent renal stones. A total of 56 patients aged <16 years from four institutions were enrolled in our study. Asymptomatic, clinically insignificant residual fragments measuring <4 mm or a complete stone-free status was accepted as the criterion for clinical success. Complications were evaluated according to the modified Clavien classification. The mean age of the patients was 7.8 ± 4.5 years. The mean stone size was calculated as 24.07 ± 10.4 mm. The median operative and fluoroscopy times were 53.2 min (15-170 min) and 172.4 s (5-520 s), respectively. The success rate after PNL monotherapy was 87.4%; the total success rate with shock wave lithotripsy used as an auxillary treatment method was detected as 94.6%. The total complication rate was 19.6% (11 patients). No adjacent organ injury was observed. All of the complications that occurred were minor according to the Clavien classification (Clavien Grades I-II). PNL can be applied to radiolucent pediatric renal stones in children with similar success, and complication rates as noted for radiopaque stones.

  17. Julie D. Baker - Associate Laboratory Director | NREL

    Science.gov Websites

    her most recent role at INL, Baker has served in a variety of operations, engineering, science and role as special assistant to INL's laboratory director. During that time, Baker engaged in the full

  18. The Case for Sustainable Laboratories: First Steps at Harvard University

    ERIC Educational Resources Information Center

    Woolliams, Jessica; Lloyd, Matthew; Spengler, John D.

    2005-01-01

    Purpose: Laboratories typically consume 4-5 times more energy than similarly-sized commercial space. This paper adds to a growing dialogue about how to "green" a laboratory's design and operations. Design/methodology/approach: The paper is divided into three sections. The first section reviews the background and theoretical issues. A…

  19. Life Sciences Laboratories for the Shuttle/Spacelab

    NASA Technical Reports Server (NTRS)

    Schulte, L. O.; Kelly, H. B.; Secord, T. C.

    1976-01-01

    Space Shuttle and Spacelab missions will provide scientists with their first opportunity to participate directly in research in space for all scientific disciplines, particularly the Life Sciences. Preparations are already underway to ensure the success of these missions. The paper summarizes the results of the 1975 NASA-funded Life Sciences Laboratories definition study which defined several long-range life sciences research options and the laboratory designs necessary to accomplish high-priority life sciences research. The implications and impacts of Spacelab design and development on the life sciences missions are discussed. An approach is presented based upon the development of a general-purposs laboratory capability and an inventory of common operational research equipment for conducting life sciences research. Several life sciences laboratories and their capabilities are described to demonstrate the systems potentially available to the experimenter for conducting biological and medical research.

  20. Performance indicators for quality in surgical and laboratory services at Muhimbili National Hospital (MNH) in Tanzania.

    PubMed

    Mbembati, Naboth A; Mwangu, Mugwira; Muhondwa, Eustace P Y; Leshabari, Melkizedek M

    2008-04-01

    Muhimbili National Hospital (MNH), a teaching and national referral hospital, is undergoing major reforms to improve the quality of health care. We performed a retrospective descriptive study using a set of performance indicators for the surgical and laboratory services of MNH in years 2001 and 2002, to help monitor and evaluate the impact of reforms on the quality of health care during and after the reform process. Hospital records were reviewed and information recorded for planned and postponed operations, laboratory equipment, reagents, laboratory tests and quality assurance programmes. In the year 2001 a total of 4332 non-emergency operations were planned, 3313 operations were performed and 1019 (23.5%) operations were postponed. In the year 2002, 4301 non-emergency operations were planned, 3046 were performed and 1255 (29%) were postponed. The most common reasons for operation postponement were "time-barred", interference by emergency operations, no show of patients and inoperable anaesthetic machines. Equipment problems and supply and staff shortages together accounted for one quarter of postponements. In the laboratory, a lack of equipment prevented some tests, but quality assurance was performed for most tests. Current surgical services at MNH are inadequate; operating theatres require modern, functioning equipment and adequate supplies of consumables to provide satisfactory care.

  1. THE LANGUAGE LABORATORY--SELECTED READINGS.

    ERIC Educational Resources Information Center

    Modern Language Association of America, New York, NY.

    THIS PACKET OF ARTICLES AND BOOKLETS, PUBLISHED FROM 1961 TO 1965, IS DESIGNED FOR PERSONS INTERESTED IN THE USE OF THE LANGUAGE LABORATORY IN THEIR FOREIGN LANGUAGE PROGRAMS. INCLUDED ARE--(1) "A DOZEN DO'S AND DON'TS FOR PLANNING AND OPERATING A LANGUAGE LAB OR AN ELECTRONIC CLASSROOM IN A HIGH SCHOOL," (2) "MODERN FOREIGN LANGUAGES IN HIGH…

  2. LDRD 2016 Annual Report: Laboratory Directed Research and Development Program Activities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hatton, D.

    Each year, Brookhaven National Laboratory (BNL) is required to provide a program description and overview of its Laboratory Directed Research and Development Program (LDRD) to the Department of Energy (DOE) in accordance with DOE Order 413.2C dated October 22, 2015. This report provides a detailed look at the scientific and technical activities for each of the LDRD projects funded by BNL in FY 2016, as required. In FY 2016, the BNL LDRD Program funded 48 projects, 21 of which were new starts, at a total cost of $11.5M. The investments that BNL makes in its LDRD program support the Laboratory’smore » strategic goals. BNL has identified four Critical Outcomes that define the Laboratory’s scientific future and that will enable it to realize its overall vision. Two operational Critical Outcomes address essential operational support for that future: renewal of the BNL campus; and safe, efficient laboratory operations.« less

  3. Framework for Leadership and Training of Biosafety Level 4 Laboratory Workers

    PubMed Central

    Anderson, Kevin; Bloom, Marshall E.; Estep, James E.; Feldmann, Heinz; Geisbert, Joan B.; Geisbert, Thomas W.; Hensley, Lisa; Holbrook, Michael; Jahrling, Peter B.; Ksiazek, Thomas G.; Korch, George; Patterson, Jean; Skvorak, John P.; Weingartl, Hana

    2008-01-01

    Construction of several new Biosafety Level 4 (BSL-4) laboratories and expansion of existing operations have created an increased international demand for well-trained staff and facility leaders. Directors of most North American BSL-4 laboratories met and agreed upon a framework for leadership and training of biocontainment research and operations staff. They agreed on essential preparation and training that includes theoretical consideration of biocontainment principles, practical hands-on training, and mentored on-the-job experiences relevant to positional responsibilities as essential preparation before a person’s independent access to a BSL-4 facility. They also agreed that the BSL-4 laboratory director is the key person most responsible for ensuring that staff members are appropriately prepared for BSL-4 operations. Although standardized certification of training does not formally exist, the directors agreed that facility-specific, time-limited documentation to recognize specific skills and experiences of trained persons is needed. PMID:18976549

  4. A computer-managed undergraduate physics laboratory

    NASA Astrophysics Data System (ADS)

    Kalman, C. S.

    1987-01-01

    Seventeen one-semester undergraduate laboratory courses are managed by a microcomputer system at Concordia University. Students may perform experiments at any time during operating hours. The computer administers pre- and post-tests. Considerable savings in manpower costs is achieved. The system also provides many pedagogical advantages.

  5. Definition of Life Sciences laboratories for shuttle/Spacelab. Volume 1: Executive summary

    NASA Technical Reports Server (NTRS)

    1975-01-01

    Research requirements and the laboratories needed to support a Life Sciences research program during the shuttle/Spacelab era were investigated. A common operational research equipment inventory was developed to support a comprehensive but flexible Life Sciences program. Candidate laboratories and operational schedules were defined and evaluated in terms of accomodation with the Spacelab and overall program planning. Results provide a firm foundation for the initiation of a life science program for the shuttle era.

  6. Accelerator-based techniques for the support of senior-level undergraduate physics laboratories

    NASA Astrophysics Data System (ADS)

    Williams, J. R.; Clark, J. C.; Isaacs-Smith, T.

    2001-07-01

    Approximately three years ago, Auburn University replaced its aging Dynamitron accelerator with a new 2MV tandem machine (Pelletron) manufactured by the National Electrostatics Corporation (NEC). This new machine is maintained and operated for the University by Physics Department personnel, and the accelerator supports a wide variety of materials modification/analysis studies. Computer software is available that allows the NEC Pelletron to be operated from a remote location, and an Internet link has been established between the Accelerator Laboratory and the Upper-Level Undergraduate Teaching Laboratory in the Physics Department. Additional software supplied by Canberra Industries has also been used to create a second Internet link that allows live-time data acquisition in the Teaching Laboratory. Our senior-level undergraduates and first-year graduate students perform a number of experiments related to radiation detection and measurement as well as several standard accelerator-based experiments that have been added recently. These laboratory exercises will be described, and the procedures used to establish the Internet links between our Teaching Laboratory and the Accelerator Laboratory will be discussed.

  7. Performance and economic evaluation of the seahorse natural gas hot water heater conversion at Fort Stewart. Interim report, 1994 Summer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Winiarski, D.W.

    1995-01-01

    The federal government is the largest single energy consumer in the United States cost valued at nearly $10 billion annually. The US Department of Energy`s (DOE) Federal Energy Management Program (FEMP) supports efforts to reduce energy use and associated expenses in the federal sector. One such effort, the New Technology Demonstration Program (NTDP), seeks to evaluate new energy-saving US technologies and secure their more timely adoption by the US government. Pacific Northwest Laboratory (PNL) is one of four DOE laboratories that participate in the New Technologies Demonstration Program, providing technical expertise and equipment to evaluate new, energy-saving technologies being studiedmore » under that program. This interim report provides the results of a field evaluation that PNL conducted for DOE/FEMP and the US Department of Defense (DoD) Strategic Environmental Research and Development Program (SERDP) to examine the performance of a candidate energy-saving technology-a hot water heater conversion system to convert electrically heated hot water tanks to natural gas fuel. The unit was installed at a single residence at Fort Stewart, a US Army base in Georgia, and the performance was monitored under the NTDP. Participating in this effort under a Cooperative Research and Development Agreement (CRADA) were Gas Fired Products, developers of the technology; the Public Service Company of North Carolina; Atlanta Gas Light Company; the Army Corps of Engineers; Fort Stewart; and Pacific Northwest Laboratory.« less

  8. Laboratory Directed Research and Development annual report, fiscal year 1997

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-03-01

    The Department of Energy Order 413.2(a) establishes DOE`s policy and guidelines regarding Laboratory Directed Research and Development (LDRD) at its multiprogram laboratories. As described in 413.2, LDRD is research and development of a creative and innovative nature which is selected by the Laboratory Director or his or her designee, for the purpose of maintaining the scientific and technological vitality of the Laboratory and to respond to scientific and technological opportunities in conformance with the guidelines in this Order. DOE Order 413.2 requires that each laboratory submit an annual report on its LDRD activities to the cognizant Secretarial Officer through themore » appropriate Operations Office Manager. The report provided in this document represents Pacific Northwest National Laboratory`s LDRD report for FY 1997.« less

  9. Lumber drying and heat sterilization research at the U.S. Forest Products Laboratory

    Treesearch

    William T. Simpson

    2002-01-01

    The Forest Products Laboratory (FPL) has a long history of research and technology transfer in lumber drying. Many of the dry kiln schedules used in industry today were developed by the staff of the Laboratory, and for many years the Laboratory conducted a kiln drying short course for training dry kiln operators. The purpose of this report is to describe the Laboratory...

  10. Lisa Smith in MSFC's Laboratory Training Complex

    NASA Image and Video Library

    2015-02-11

    LISA SMITH, THE TRAINING TEAM LEAD IN MARSHALL'S MISSION OPERATIONS LAB, EXAMINES THE DRAWERS IN THE GLACIER MOCK-UP, A TRAINING VERSION OF A FREEZER ON THE INTERNATIONAL SPACE STATION INSTALLED IN THE MARSHALL CENTER'S LABORATORY TRAINING COMPLEX

  11. Efficacy of the RADPAD Protection Drape in Reducing Operators' Radiation Exposure in the Catheterization Laboratory: A Sham-Controlled Randomized Trial.

    PubMed

    Vlastra, Wieneke; Delewi, Ronak; Sjauw, Krischan D; Beijk, Marcel A; Claessen, Bimmer E; Streekstra, Geert J; Bekker, Robbert J; van Hattum, Juliette C; Wykrzykowska, Joanna J; Vis, Marije M; Koch, Karel T; de Winter, Robbert J; Piek, Jan J; Henriques, José P S

    2017-11-01

    Interventional cardiologists are increasingly exposed to radiation-induced diseases like cataract and the stochastic risk of left-sided brain tumors. The RADPAD is a sterile, disposable, lead-free shield placed on the patient with the aim to minimize operator-received scatter radiation. The objective of the trial was to examine the RADPAD's efficacy in a real-world situation. In the current, double-blind, sham-controlled, all-comer trial, patients undergoing diagnostic catheterization or percutaneous coronary interventions were randomized in a 1:1:1 ratio to a radiation absorbing shield (RADPAD), standard treatment (NOPAD), or a sham shield (SHAMPAD). The sham shield allowed testing for shield-induced radiation behavior. The primary outcome was the difference in relative exposure of the primary operator between the RADPAD and NOPAD arms and was defined as the ratio between operator's exposure (E in µSv) and patient exposure (dose area product in mGy·cm 2 ), measured per procedure. A total of 766 consecutive coronary procedures were randomized to the use of RADPAD (N=255), NOPAD (N=255), or SHAMPAD (N=256). The use of RADPAD was associated with a 20% reduction in relative operator exposure compared with that of NOPAD ( P =0.01) and a 44% relative exposure reduction compared with the use of a SHAMPAD ( P <0.001). Use of the SHAMPAD was associated with a 43% higher relative radiation exposure than procedures with NOPAD ( P =0.009). In clinical daily practice, the standard use of the RADPAD radiation shield reduced operator radiation exposure compared with procedures with NOPAD or SHAMPAD. This study supports the routine use of RADPAD in the catheterization laboratory. URL: https://www.clinicaltrials.gov. Unique identifier: NCT03139968. © 2017 American Heart Association, Inc.

  12. Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 3. Aerobiology.

    PubMed

    Bohannon, J Kyle; Janosko, Krisztina; Holbrook, Michael R; Barr, Jason; Pusl, Daniela; Bollinger, Laura; Coe, Linda; Hensley, Lisa E; Jahrling, Peter B; Wada, Jiro; Kuhn, Jens H; Lackemeyer, Matthew G

    2016-10-03

    Aerosol or inhalational studies of high-consequence pathogens have recently been increasing in number due to the perceived threat of intentional aerosol releases or unexpected natural aerosol transmission. Specific laboratories designed to perform these experiments require tremendous engineering controls to provide a safe and secure working environment and constant systems maintenance to sustain functionality. Class III biosafety cabinets, also referred to as gloveboxes, are gas-tight enclosures with non-opening windows. These cabinets are maintained under negative pressure by double high-efficiency-particulate-air (HEPA)-filtered exhaust systems and are the ideal primary containment for housing aerosolization equipment. A well planned workflow between staff members within high containment from, for instance, an animal biosafety level-4 (ABSL-4) suit laboratory to the ABSL-4 cabinet laboratory is a crucial component for successful experimentation. For smooth study execution, establishing a communication network, moving equipment and subjects, and setting up and placing equipment, requires staff members to meticulously plan procedures prior to study initiation. Here, we provide an overview and a visual representation of how aerobiology research is conducted at the National Institutes of Health, National Institute of Allergy and Infectious Diseases Integrated Research Facility at Fort Detrick, Maryland, USA, within an ABSL-4 environment.

  13. Selecting automation for the clinical chemistry laboratory.

    PubMed

    Melanson, Stacy E F; Lindeman, Neal I; Jarolim, Petr

    2007-07-01

    Laboratory automation proposes to improve the quality and efficiency of laboratory operations, and may provide a solution to the quality demands and staff shortages faced by today's clinical laboratories. Several vendors offer automation systems in the United States, with both subtle and obvious differences. Arriving at a decision to automate, and the ensuing evaluation of available products, can be time-consuming and challenging. Although considerable discussion concerning the decision to automate has been published, relatively little attention has been paid to the process of evaluating and selecting automation systems. To outline a process for evaluating and selecting automation systems as a reference for laboratories contemplating laboratory automation. Our Clinical Chemistry Laboratory staff recently evaluated all major laboratory automation systems in the United States, with their respective chemistry and immunochemistry analyzers. Our experience is described and organized according to the selection process, the important considerations in clinical chemistry automation, decisions and implementation, and we give conclusions pertaining to this experience. Including the formation of a committee, workflow analysis, submitting a request for proposal, site visits, and making a final decision, the process of selecting chemistry automation took approximately 14 months. We outline important considerations in automation design, preanalytical processing, analyzer selection, postanalytical storage, and data management. Selecting clinical chemistry laboratory automation is a complex, time-consuming process. Laboratories considering laboratory automation may benefit from the concise overview and narrative and tabular suggestions provided.

  14. The Virtual Geophysics Laboratory (VGL): Scientific Workflows Operating Across Organizations and Across Infrastructures

    NASA Astrophysics Data System (ADS)

    Cox, S. J.; Wyborn, L. A.; Fraser, R.; Rankine, T.; Woodcock, R.; Vote, J.; Evans, B.

    2012-12-01

    The Virtual Geophysics Laboratory (VGL) is web portal that provides geoscientists with an integrated online environment that: seamlessly accesses geophysical and geoscience data services from the AuScope national geoscience information infrastructure; loosely couples these data to a variety of gesocience software tools; and provides large scale processing facilities via cloud computing. VGL is a collaboration between CSIRO, Geoscience Australia, National Computational Infrastructure, Monash University, Australian National University and the University of Queensland. The VGL provides a distributed system whereby a user can enter an online virtual laboratory to seamlessly connect to OGC web services for geoscience data. The data is supplied in open standards formats using international standards like GeoSciML. A VGL user uses a web mapping interface to discover and filter the data sources using spatial and attribute filters to define a subset. Once the data is selected the user is not required to download the data. VGL collates the service query information for later in the processing workflow where it will be staged directly to the computing facilities. The combination of deferring data download and access to Cloud computing enables VGL users to access their data at higher resolutions and to undertake larger scale inversions, more complex models and simulations than their own local computing facilities might allow. Inside the Virtual Geophysics Laboratory, the user has access to a library of existing models, complete with exemplar workflows for specific scientific problems based on those models. For example, the user can load a geological model published by Geoscience Australia, apply a basic deformation workflow provided by a CSIRO scientist, and have it run in a scientific code from Monash. Finally the user can publish these results to share with a colleague or cite in a paper. This opens new opportunities for access and collaboration as all the resources (models

  15. Water Quality & Pollutant Source Monitoring: Field and Laboratory Procedures. Training Manual.

    ERIC Educational Resources Information Center

    Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.

    This training manual presents material on techniques and instrumentation used to develop data in field monitoring programs and related laboratory operations concerned with water quality and pollution monitoring. Topics include: collection and handling of samples; bacteriological, biological, and chemical field and laboratory methods; field…

  16. The Gravity Recovery and Interior Laboratory Mission

    NASA Technical Reports Server (NTRS)

    Lehman, David H.; Hoffman, Tom L.; Havens, Glen G.

    2013-01-01

    The Gravity Recovery and Interior Laboratory (GRAIL) mission, launched in September 2011, successfully completed its Primary Science Mission in June 2012 and is currently in Extended Mission operations. Competitively selected under a NASA Announcement of Opportunity in December 2007, GRAIL is a Discovery Program mission subject to a mandatory project cost cap. The purpose of the mission is to precisely map the gravitational field of the Moon to reveal its internal structure from crust to core, determine its thermal evolution, and extend this knowledge to other planets. The mission uses twin spacecraft flying in tandem to provide the gravity map. The GRAIL Flight System, consisting of the spacecraft and payload, was developed based on significant heritage from previous missions such an experimental U.S. Air Force satellite, the Mars Reconnaissance Orbiter (MRO) mission, and the Gravity Recovery and Climate Experiment (GRACE) mission. The Mission Operations System (MOS) was based on high-heritage multimission operations developed by NASA's Jet Propulsion Laboratory and Lockheed Martin. Both the Flight System and MOS were adapted to meet the unique challenges posed by the GRAIL mission design. This paper summarizes the implementation challenges and accomplishments of getting GRAIL ready for launch. It also discusses the in-flight challenges and experiences of operating two spacecraft, and mission results.

  17. Clinical efficacy and safety of transcatheter embolization for vascular complications after percutaneous nephrolithotomy

    PubMed Central

    Poyraz, Necdet; Balasar, Mehmet; Gökmen, İbrahim Erdem; Koç, Osman; Aydın, Arif; Göger, Yunus Emre; Öztürk, Ahmet

    2017-01-01

    Introduction Percutaneous nephrolithotomy (PNL) is the preferred procedure for safe and effective surgical treatment of kidney stones. Hemorrhage is the most serious complication of PNL, resulting from pseudoaneurysm (PA) or arteriovenous fistula (AVF), and can usually be controlled with conservative treatment. Aim To evaluate endovascular treatments and outcomes of vascular complications observed after PNL. Material and methods We retrospectively reviewed data on 19 patients who underwent renal embolization due to post-PNL renal artery bleeding between March 2005 and September 2016. Embolization materials included embolization coils and glue. The incidence of post-PNL vascular complications and their endovascular treatments, outcomes, and the follow-up data were analyzed. Results Nineteen (1.1%) of 1,609 patients (mean age: 44.9 years, range: 19–75 years) underwent angiography and subsequent transcatheter embolization to control bleeding. The mean time to onset of hemorrhage was 7.2 days after PNL (range: 3–18 days). The PNL entry site was the lower calyx in 15 patients, the middle calyx in 3, and the upper calyx in 1. PA, AVF, and PA plus AVF occurred in 14, 5, and 3 of the 19 renal angiography patients, respectively. Embolization of the affected vessels was successful in all 19 patients. The embolization materials of coil, glue, and coil plus glue were used in 16, 3, and 2 patients, respectively. Conclusions Severe hematuria is a rare complication of PNL and can be successfully treated with transcatheter embolization. PMID:29362656

  18. Rationale for cost-effective laboratory medicine.

    PubMed Central

    Robinson, A

    1994-01-01

    There is virtually universal consensus that the health care system in the United States is too expensive and that costs need to be limited. Similar to health care costs in general, clinical laboratory expenditures have increased rapidly as a result of increased utilization and inflationary trends within the national economy. Economic constraints require that a compromise be reached between individual welfare and limited societal resources. Public pressure and changing health care needs have precipitated both subtle and radical laboratory changes to more effectively use allocated resources. Responsibility for excessive laboratory use can be assigned primarily to the following four groups: practicing physicians, physicians in training, patients, and the clinical laboratory. The strategies to contain escalating health care costs have ranged from individualized physician education programs to government intervention. Laboratories have responded to the fiscal restraints imposed by prospective payment systems by attempting to reduce operational costs without adversely impacting quality. Although cost containment directed at misutilization and overutilization of existing services has conserved resources, to date, an effective cost control mechanism has yet to be identified and successfully implemented on a grand enough scale to significantly impact health care expenditures in the United States. PMID:8055467

  19. Hanford Environmental Dose Reconstruction Project. Monthly report, December 1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Finch, S.M.; McMakin, A.H.

    1991-12-31

    The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation doses that individuals and populations could have received from nuclear operations at Hanford since 1944. The project is being managed and conducted by the Pacific Northwest Laboratory (PNL) under the direction of an independent Technical Steering Panel (TSP). The TSP consists of experts in environmental pathways, epidemiology, surface-water transport, ground-water transport, statistics, demography, agriculture, meteorology, nuclear engineering, radiation dosimetry, and cultural anthropology. Included are appointed technical members representing the states of Oregon and Washington, a representative of Native American tribes, and an individual representing the public.more » The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed, from release to impact on human (dose estimates): Source Terms; Environmental Transport; Environmental Monitoring Data; Demographics, Agriculture, Food Habits and; Environmental Pathways and Dose Estimates.« less

  20. Hanford Environmental Dose Reconstruction Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Finch, S.M.; McMakin, A.H.

    1991-01-01

    The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation doses that individuals and populations could have received from nuclear operations at Hanford since 1944. The project is being managed and conducted by the Pacific Northwest Laboratory (PNL) under the direction of an independent Technical Steering Panel (TSP). The TSP consists of experts in environmental pathways, epidemiology, surface-water transport, ground-water transport, statistics, demography, agriculture, meteorology, nuclear engineering, radiation dosimetry, and cultural anthropology. Included are appointed technical members representing the states of Oregon and Washington, a representative of Native American tribes, and an individual representing the public.more » The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed, from release to impact on human (dose estimates): Source Terms; Environmental Transport; Environmental Monitoring Data; Demographics, Agriculture, Food Habits and; Environmental Pathways and Dose Estimates.« less

  1. Glass-fiber-based neutron detectors for high- and low-flux environments

    NASA Astrophysics Data System (ADS)

    Bliss, Mary; Brodzinski, Ronald L.; Craig, Richard A.; Geelhood, Bruce D.; Knopf, Michael A.; Miley, Harry S.; Perkins, Richard W.; Reeder, Paul L.; Sunberg, Debra S.; Warner, Ray A.; Wogman, Ned A.

    1995-09-01

    Pacific Northwest Laboratory (PNL) has fabricated cerium-activated lithium silicate scintillating fibers via a hot-downdraw process. These fibers typically have a operational transmission length (e(superscript -1) length) of greater than 2 meters. This permits the fabrication of devices which were not possible to consider. Scintillating fibers permit conformable devices, large-area devices, and extremely small devices; in addition, as the thermal-neutron sensitive elements in a fast neutron detection system, scintillating fibers can be dispersed within moderator, improving neutron economy, over that possible with commercially available (superscript 3)He or BF(subscript 3) proportional counters. These fibers can be used for national-security applications, in medical applications, in the nuclear-power industry, and for personnel protection at experimental facilities. Data are presented for devices based on single fibers and devices made up of ribbons containing many fibers under high-and low-flux conditions.

  2. LANL continuity of operations plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Senutovitch, Diane M

    2010-12-22

    The Los Alamos National Laboratory (LANL) is a premier national security research institution, delivering scientific and engineering solutions for the nation's most crucial and complex problems. Our primary responsibility is to ensure the safety, security, and reliability of the nation's nuclear stockpile. LANL emphasizes worker safety, effective operational safeguards and security, and environmental stewardship, outstanding science remains the foundation of work at the Laboratory. In addition to supporting the Laboratory's core national security mission, our work advances bioscience, chemistry, computer science, earth and environmental sciences, materials science, and physics disciplines. To accomplish LANL's mission, we must ensure that the Laboratorymore » EFs continue to be performed during a continuity event, including localized acts of nature, accidents, technological or attack-related emergencies, and pandemic or epidemic events. The LANL Continuity of Operations (COOP) Plan documents the overall LANL COOP Program and provides the operational framework to implement continuity policies, requirements, and responsibilities at LANL, as required by DOE 0 150.1, Continuity Programs, May 2008. LANL must maintain its ability to perform the nation's PMEFs, which are: (1) maintain the safety and security of nuclear materials in the DOE Complex at fixed sites and in transit; (2) respond to a nuclear incident, both domestically and internationally, caused by terrorist activity, natural disaster, or accident, including mobilizing the resources to support these efforts; and (3) support the nation's energy infrastructure. This plan supports Continuity of Operations for Los Alamos National Laboratory (LANL). This plan issues LANL policy as directed by the DOE 0 150.1, Continuity Programs, and provides direction for the orderly continuation of LANL EFs for 30 days of closure or 60 days for a pandemic/epidemic event. Initiation of COOP operations may be required to support

  3. THE GREEN DORM: A SUSTAINABLE RESIDENCE AND LIVING LABORATORY FOR STANFORD UNIVERSITY

    EPA Science Inventory

    The Lotus Living Laboratory at Stanford University is exploring sustainable building technologies and sustainable living habits through the design, construction and operation of The Green Dorm, an innovative facility containing residential, laboratory and commons space. Both ...

  4. Leading Antibacterial Laboratory Research by Integrating Conventional and Innovative Approaches: The Laboratory Center of the Antibacterial Resistance Leadership Group.

    PubMed

    Manca, Claudia; Hill, Carol; Hujer, Andrea M; Patel, Robin; Evans, Scott R; Bonomo, Robert A; Kreiswirth, Barry N

    2017-03-15

    The Antibacterial Resistance Leadership Group (ARLG) Laboratory Center (LC) leads the evaluation, development, and implementation of laboratory-based research by providing scientific leadership and supporting standard/specialized laboratory services. The LC has developed a physical biorepository and a virtual biorepository. The physical biorepository contains bacterial isolates from ARLG-funded studies located in a centralized laboratory and they are available to ARLG investigators. The Web-based virtual biorepository strain catalogue includes well-characterized gram-positive and gram-negative bacterial strains published by ARLG investigators. The LC, in collaboration with the ARLG Leadership and Operations Center, developed procedures for review and approval of strain requests, guidance during the selection process, and for shipping strains from the distributing laboratories to the requesting investigators. ARLG strains and scientific and/or technical guidance have been provided to basic research laboratories and diagnostic companies for research and development, facilitating collaboration between diagnostic companies and the ARLG Master Protocol for Evaluating Multiple Infection Diagnostics (MASTERMIND) initiative for evaluation of multiple diagnostic devices from a single patient sampling event. In addition, the LC has completed several laboratory-based studies designed to help evaluate new rapid molecular diagnostics by developing, testing, and applying a MASTERMIND approach using purified bacterial strains. In collaboration with the ARLG's Statistical and Data Management Center (SDMC), the LC has developed novel analytical strategies that integrate microbiologic and genetic data for improved and accurate identification of antimicrobial resistance. These novel approaches will aid in the design of future ARLG studies and help correlate pathogenic markers with clinical outcomes. The LC's accomplishments are the result of a successful collaboration with the ARLG

  5. Using the Human Systems Simulation Laboratory at Idaho National Laboratory for Safety Focused Research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joe, Jeffrey .C; Boring, Ronald L.

    Under the United States (U.S.) Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) program, researchers at Idaho National Laboratory (INL) have been using the Human Systems Simulation Laboratory (HSSL) to conduct critical safety focused Human Factors research and development (R&D) for the nuclear industry. The LWRS program has the overall objective to develop the scientific basis to extend existing nuclear power plant (NPP) operating life beyond the current 60-year licensing period and to ensure their long-term reliability, productivity, safety, and security. One focus area for LWRS is the NPP main control room (MCR), because many of the instrumentation andmore » control (I&C) system technologies installed in the MCR, while highly reliable and safe, are now difficult to replace and are therefore limiting the operating life of the NPP. This paper describes how INL researchers use the HSSL to conduct Human Factors R&D on modernizing or upgrading these I&C systems in a step-wise manner, and how the HSSL has addressed a significant gap in how to upgrade systems and technologies that are built to last, and therefore require careful integration of analog and new advanced digital technologies.« less

  6. Site Environmental Report for Calendar Year 2013. DOE Operations at The Boeing Company, Santa Susana Field Laboratory, Area IV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2014-06-30

    This Annual Site Environmental Report (ASER) for 2013 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of the Santa Susana Field Laboratory (SSFL). The Energy Technology Engineering Center (ETEC), a government-owned, company-operated test facility, was located in Area IV. The operations in Area IV included development, fabrication, operation and disassembly of nuclear reactors, reactor fuel, and other radioactive materials. Other activities in the area involved the operation of large-scale liquid metal facilities that were used for testing non-nuclear liquid metal fast breeder reactor components. All nuclear work was terminated in 1988,more » and all subsequent radiological work has been directed toward environmental restoration and decontamination and decommissioning (D&D) of the former nuclear facilities and their associated sites. Liquid metal research and development ended in 2002. Since May 2007, the D&D operations in Area IV have been suspended by the DOE, but the environmental monitoring and characterization programs have continued. Results of the radiological monitoring program for the calendar year 2013 continue to indicate that there are no significant releases of radioactive material from Area IV of SSFL. All potential exposure pathways are sampled and/or monitored, including air, soil, surface water, groundwater, direct radiation, transfer of property (land, structures, waste), and recycling. Due to the suspension of D&D activities in Area IV, no effluents were released into the atmosphere during 2013. Therefore, the potential radiation dose to the general public through airborne release was zero. Similarly, the radiation dose to an offsite member of the public (maximally exposed individual) due to direct radiation from SSFL is indistinguishable from background. All radioactive wastes are processed for disposal at DOE disposal sites and/or other licensed sites approved by DOE for

  7. Review of technologies for the pretreatment of retrieved single-shell tank waste at Hanford

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gerber, M.A.

    1992-08-01

    The purpose of the study reported here was to identify and evaluate innovative processes that could be used to pretreat mixed waste retrieved from the 149 single-shell tanks (SSTs) on the US Department of Energy's (DOE) Hanford site. The information was collected as part of the Single Shell Tank Waste Treatment project at Pacific Northwest Laboratory (PNL). The project is being conducted for Westinghouse Hanford Company under their SST Disposal Program.

  8. Review of technologies for the pretreatment of retrieved single-shell tank waste at Hanford

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gerber, M.A.

    1992-08-01

    The purpose of the study reported here was to identify and evaluate innovative processes that could be used to pretreat mixed waste retrieved from the 149 single-shell tanks (SSTs) on the US Department of Energy`s (DOE) Hanford site. The information was collected as part of the Single Shell Tank Waste Treatment project at Pacific Northwest Laboratory (PNL). The project is being conducted for Westinghouse Hanford Company under their SST Disposal Program.

  9. Operating experience review of an INL gas monitoring system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cadwallader, Lee C.; DeWall, K. G.; Herring, J. S.

    2015-03-12

    This article describes the operations of several types of gas monitors in use at the Idaho National Laboratory (INL) High Temperature Electrolysis Experiment (HTE) laboratory. The gases monitored in the lab room are hydrogen, carbon monoxide, carbon dioxide, and oxygen. The operating time, calibration, and both actual and unwanted alarms are described. The calibration session time durations are described. In addition, some simple calculations are given to estimate the reliability of these monitors and the results are compared to operating experiences of other types of monitors.

  10. Removal design report for the 108-F Biological Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1997-09-01

    Most of the 100-F facilities were deactivated with the reactor and have since been demolished. Of the dozen or so reactor-related structures, only the 105-F Reactor Building and the 108-F Biology Laboratory remain standing today. The 108-F Biology Laboratory was intended to be used as a facility for the mixing and addition of chemicals used in the treatment of the reactor cooling water. Shortly after F Reactor began operation, it was determined that the facility was not needed for this purpose. In 1949, the building was converted for use as a biological laboratory. In 1962, the lab was expanded bymore » adding a three-story annex to the original four-story structure. The resulting lab had a floor area of approximately 2,883 m{sup 2} (main building and annex) that operated until 1973. The building contained 47 laboratories, a number of small offices, a conference room, administrative section, lunch and locker rooms, and a heavily shielded, high-energy exposure cell. The purpose of this removal design report is to establish the methods of decontamination and decommissioning and the supporting functions associated with facility removal and disposal.« less

  11. Remotely accessible laboratory for MEMS testing

    NASA Astrophysics Data System (ADS)

    Sivakumar, Ganapathy; Mulsow, Matthew; Melinger, Aaron; Lacouture, Shelby; Dallas, Tim E.

    2010-02-01

    We report on the construction of a remotely accessible and interactive laboratory for testing microdevices (aka: MicroElectroMechancial Systems - MEMS). Enabling expanded utilization of microdevices for research, commercial, and educational purposes is very important for driving the creation of future MEMS devices and applications. Unfortunately, the relatively high costs associated with MEMS devices and testing infrastructure makes widespread access to the world of MEMS difficult. The creation of a virtual lab to control and actuate MEMS devices over the internet helps spread knowledge to a larger audience. A host laboratory has been established that contains a digital microscope, microdevices, controllers, and computers that can be logged into through the internet. The overall layout of the tele-operated MEMS laboratory system can be divided into two major parts: the server side and the client side. The server-side is present at Texas Tech University, and hosts a server machine that runs the Linux operating system and is used for interfacing the MEMS lab with the outside world via internet. The controls from the clients are transferred to the lab side through the server interface. The server interacts with the electronics required to drive the MEMS devices using a range of National Instruments hardware and LabView Virtual Instruments. An optical microscope (100 ×) with a CCD video camera is used to capture images of the operating MEMS. The server broadcasts the live video stream over the internet to the clients through the website. When the button is pressed on the website, the MEMS device responds and the video stream shows the movement in close to real time.

  12. Particle Size Distribution of Serratia marcescens Aerosols Created During Common Laboratory Procedures and Simulated Laboratory Accidents

    PubMed Central

    Kenny, Michael T.; Sabel, Fred L.

    1968-01-01

    Andersen air samplers were used to determine the particle size distribution of Serratia marcescens aerosols created during several common laboratory procedures and simulated laboratory accidents. Over 1,600 viable particles per cubic foot of air sampled were aerosolized during blending operations. More than 98% of these particles were less than 5 μ in size. In contrast, 80% of the viable particles aerosolized by handling lyophilized cultures were larger than 5 μ. Harvesting infected eggs, sonic treatment, centrifugation, mixing cultures, and dropping infectious material produced aerosols composed primarily of particles in the 1.0- to 7.5-μ size range. Images Fig. 1 PMID:4877498

  13. Anderson uses laptop computer in the U.S. Laboratory during Joint Operations

    NASA Image and Video Library

    2007-06-13

    S117-E-07134 (12 June 2007) --- Astronaut Clayton Anderson, Expedition 15 flight engineer, uses a computer near the Microgravity Science Glovebox (MSG) in the Destiny laboratory of the International Space Station while Space Shuttle Atlantis (STS-117) was docked with the station. Astronaut Sunita Williams, flight engineer, is at right.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, G.P.; Keller, J.M.; Stucky, D.J.

    The US Army Forces Command (FORSCOM) has tasked the US Department of Energy (DOE) Federal Energy Management Program (FEMP), supported by the Pacific Northwest Laboratory, to identify, evaluate, and assist in acquiring all cost-effective energy projects at Fort Stewart. This is part of a model program that PNL is designing to support energy-use decisions in the federal sector. This report provides the results of the fossil fuel and electric energy resource opportunity (ERO) assessments performed by PNL at the FORSCOM Fort Stewart facility located approximately 25 miles southwest of Savannah, Georgia. It is a companion report to Volume 1, Executivemore » Summary, and Volume 2, Baseline Detail. The results of the analyses of EROs are presented in 11 common energy end-use categories (e.g., boilers and furnaces, service hot water, and building lighting). A narrative description of each ERO is provided, along with a table detailing information on the installed cost, energy and dollar savings; impacts on operations and maintenance (O&M); and, when applicable, a discussion of energy supply and demand, energy security, and environmental issues. A description of the evaluation methodologies and technical and cost assumptions is also provided for each ERO. Summary tables present the cost-effectiveness of energy end-use equipment before and after the implementation of each ERO. The tables also present the results of the life-cycle cost (LCC) analysis indicating the net present value (NPV) and savings to investment ratio (SIR) of each ERO.« less

  15. RISK MANAGEMENT EVALUATION FOR CONCENTRATED ANIMAL FEEDING OPERATIONS

    EPA Science Inventory

    The National Risk Management Research Laboratory (NRMRL) developed a Risk Management Evaluation (RME) to provide information needed to help plan future research in the Laboratory dealing with the environmental impact of concentrated animal feeding operations (CAFOs). Agriculture...

  16. Hadfield installing UBNT Sensors in the U.S. Laboratory

    NASA Image and Video Library

    2013-02-01

    View of Canadian Space Agency (CSA) Chris Hadfield,Expedition 34 Flight Engineer (FE),installing Ultra-Sonic Background Noise Tests (UBNT) sensors behind rack in the U.S. Laboratory using the International Space Station (ISS) as Testbed for Analog Research (ISTAR) procedures. These sensors detect high frequency noise levels generated by ISS hardware and equipment operating within the U.S. Laboratory. Photo was taken during Expedition 34.

  17. Adding value to laboratory medicine: a professional responsibility.

    PubMed

    Beastall, Graham H

    2013-01-01

    Laboratory medicine is a medical specialty at the centre of healthcare. When used optimally laboratory medicine generates knowledge that can facilitate patient safety, improve patient outcomes, shorten patient journeys and lead to more cost-effective healthcare. Optimal use of laboratory medicine relies on dynamic and authoritative leadership outside as well as inside the laboratory. The first responsibility of the head of a clinical laboratory is to ensure the provision of a high quality service across a wide range of parameters culminating in laboratory accreditation against an international standard, such as ISO 15189. From that essential baseline the leadership of laboratory medicine at local, national and international level needs to 'add value' to ensure the optimal delivery, use, development and evaluation of the services provided for individuals and for groups of patients. A convenient tool to illustrate added value is use of the mnemonic 'SCIENCE'. This tool allows added value to be considered in seven domains: standardisation and harmonisation; clinical effectiveness; innovation; evidence-based practice; novel applications; cost-effectiveness; and education of others. The assessment of added value in laboratory medicine may be considered against a framework that comprises three dimensions: operational efficiency; patient management; and patient behaviours. The profession and the patient will benefit from sharing examples of adding value to laboratory medicine.

  18. The Aeronautical Laboratory of the Stockholm Technical Institute

    NASA Technical Reports Server (NTRS)

    Malmer, Ivar

    1935-01-01

    This report presents a detailed analysis and history of the construction and operation of the aeronautical laboratory of the Stockholm Technical Institute. Engines and balances are discussed and experimental results are also given.

  19. Operating Experience Review of the INL HTE Gas Monitoring System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    L. C. Cadwallader; K. G. DeWall

    2010-06-01

    This paper describes the operations of several types of gas monitors in use at the Idaho National Laboratory (INL) High Temperature Electrolysis Experiment (HTE) laboratory. The gases monitored at hydrogen, carbon monoxide, carbon dioxide, and oxygen. The operating time, calibration, and unwanted alarms are described. The calibration session time durations are described. Some simple statistics are given for the reliability of these monitors and the results are compared to operating experiences of other types of monitors.

  20. Does body mass index effect the success of percutaneous nephrolithotomy?

    PubMed Central

    Şimşek, Abdülmuttalip; Özgör, Faruk; Akbulut, Mehmet Fatih; Küçüktopçu, Onur; Berberoğlu, Ahmet Yalçın; Sarılar, Ömer; Binbay, Murat; Müslümanoğlu, Ahmet Yaser

    2014-01-01

    Objective: In obese patients, the management of renal calculi presents a number of challenges for urologists. In this study, we aimed to evaluate the efficacy and safety of percutaneous nephrolithotomy (PNL) procedure in obese and morbidly obese patients. Material and methods: We retrospectively reviewed the medical files of 2360 patients treated with PNL between March 2002 and April 2013. The patients were stratified into four groups according to the World Health Organization (WHO) classification of body mass index (BMI): <25 kg/m2 (average), 25–29.9 kg/m2 (overweight), 30–39.9 kg/m2 (obese), and >40 kg/m2 (morbidly obese). Patients under 18 years of age and those with a body mass index under 18 kg/m2 were excluded from the study. Intra-, and postoperative outcomes of PNL were compared between groups. Results: A total of 2102 patients with a mean age of 43±13.62 years were enrolled in the study. The mean stone size, mean number of stones, staghorn stone rate and history of previous shock wave lithotripsy were similar in all groups. The overall stone-free rate was 82 percent. The mean operation time was longer in the morbidly obese group but it was not significantly different from that in the other groups. No differences were observed in hospital stay, complication or stone-free rate among four study groups. Conclusion: Percutaneous nephrolithotomy is a safe and effective treatment for renal stone disease. Body mass index does not affect the success or complication rate in PNL. PMID:26328160