Sample records for laboratory reference material

  1. Quality assurance and quality control in light stable isotope laboratories: A case study of Rio Grande, Texas, water samples

    USGS Publications Warehouse

    Coplen, T.B.; Qi, H.

    2009-01-01

    New isotope laboratories can achieve the goal of reporting the same isotopic composition within analytical uncertainty for the same material analysed decades apart by (1) writing their own acceptance testing procedures and putting them into their mass spectrometric or laser-based isotope-ratio equipment procurement contract, (2) requiring a manufacturer to demonstrate acceptable performance using all sample ports provided with the instrumentation, (3) for each medium to be analysed, prepare two local reference materials substantially different in isotopic composition to encompass the range in isotopic composition expected in the laboratory and calibrated them with isotopic reference materials available from the International Atomic Energy Agency (IAEA) or the US National Institute of Standards and Technology (NIST), (4) using the optimum storage containers (for water samples, sealing in glass ampoules that are sterilised after sealing is satisfactory), (5) interspersing among sample unknowns local laboratory isotopic reference materials daily (internationally distributed isotopic reference materials can be ordered at three-year intervals, and can be used for elemental analyser analyses and other analyses that consume less than 1 mg of material) - this process applies to H, C, N, O, and S isotope ratios, (6) calculating isotopic compositions of unknowns by normalising isotopic data to that of local reference materials, which have been calibrated to internationally distributed isotopic reference materials, (7) reporting results on scales normalised to internationally distributed isotopic reference materials (where they are available) and providing to sample submitters the isotopic compositions of internationally distributed isotopic reference materials of the same substance had they been analysed with unknowns, (8) providing an audit trail in the laboratory for analytical results - this trail commonly will be in electronic format and might include a laboratory information management system, (9) making at regular intervals a complete backup of laboratory analytical data (both of samples logged into the laboratory and of mass spectrometric analyses), being sure to store one copy of this backup offsite, and (10) participating in interlaboratory comparison exercises sponsored by the IAEA and other agencies at regular intervals. ?? Taylor & Francis.

  2. Interlaboratory comparison of reference materials for nitrogen-isotope-ratio measurements

    USGS Publications Warehouse

    Böhlke, John Karl; Coplen, Tyler B.

    1995-01-01

    Aliquots of seven different reference materials were distributed for an interlaboratory comparison of stable nitrogen-isotope-ratio measurements. Results from 15 laboratories were compiled and evaluated selectively to yield provisional values of 515N for each material, i, with respect to atmospheric N2 (o1SN,7air). The 515N values reported by the different laboratories are correlated in such a way that some of the major discrepancies may be removed by normalization (/. e., by altering the length of the ô N scale for each laboratory by an amount defined by local measurements of reference materials with extreme values).

  3. Recent developments in the field of environmental reference materials at the JRC Ispra.

    PubMed

    Muntau, H

    2001-06-01

    The production of reference materials for environmental analysis started in the Joint Research Centre at Ispra/Italy in 1972 with the objective of later certification by the BCR, but for obvious budget reasons only a fraction of the total production achieved at Ispra ever reached certification level, although all materials were produced according to the severe quality requirements requested for certified reference materials. Therefore, the materials not destinated to certification are in growing demand as inter-laboratory test materials and as laboratory reference materials, for internal quality control, e.g., by control charts. The history of reference material production within the Joint Research Centre is briefly reviewed and the latest additions described. New developments such as micro-scale reference materials intended for analytical methods requiring sample intakes at milligram or sub-milligram level and therefor not finding supply on the reference material market, and "wet" environmental reference materials, which meet more precisely the "real-world" environmental analysis conditions, are presented and the state-of-the-art discussed.

  4. Diffusion-controlled reference material for VOC emissions testing: proof of concept.

    PubMed

    Cox, S S; Liu, Z; Little, J C; Howard-Reed, C; Nabinger, S J; Persily, A

    2010-10-01

    Because of concerns about indoor air quality, there is growing awareness of the need to reduce the rate at which indoor materials and products emit volatile organic compounds (VOCs). To meet consumer demand for low emitting products, manufacturers are increasingly submitting materials to independent laboratories for emissions testing. However, the same product tested by different laboratories can result in very different emissions profiles because of a general lack of test validation procedures. There is a need for a reference material that can be used as a known emissions source and that will have the same emission rate when tested by different laboratories under the same conditions. A reference material was created by loading toluene into a polymethyl pentene film. A fundamental emissions model was used to predict the toluene emissions profile. Measured VOC emissions profiles using small-chamber emissions tests compared reasonably well to the emissions profile predicted using the emissions model, demonstrating the feasibility of the proposed approach to create a diffusion-controlled reference material. To calibrate emissions test chambers and improve the reproducibility of VOC emission measurements among different laboratories, a reference material has been created using a polymer film loaded with a representative VOC. Initial results show that the film's VOC emission profile measured in a conventional test chamber compares well to predictions based on independently determined material/chemical properties and a fundamental emissions model. The use of such reference materials has the potential to build consensus and confidence in emissions testing as well as 'level the playing field' for product testing laboratories and manufacturers.

  5. Baseline Assessment of 25-Hydroxyvitamin D Reference Material and Proficiency Testing/External Quality Assurance Material Commutability: A Vitamin D Standardization Program Study.

    PubMed

    Phinney, Karen W; Sempos, Christopher T; Tai, Susan S-C; Camara, Johanna E; Wise, Stephen A; Eckfeldt, John H; Hoofnagle, Andrew N; Carter, Graham D; Jones, Julia; Myers, Gary L; Durazo-Arvizu, Ramon; Miller, W Greg; Bachmann, Lorin M; Young, Ian S; Pettit, Juanita; Caldwell, Grahame; Liu, Andrew; Brooks, Stephen P J; Sarafin, Kurtis; Thamm, Michael; Mensink, Gert B M; Busch, Markus; Rabenberg, Martina; Cashman, Kevin D; Kiely, Mairead; Galvin, Karen; Zhang, Joy Y; Kinsella, Michael; Oh, Kyungwon; Lee, Sun-Wha; Jung, Chae L; Cox, Lorna; Goldberg, Gail; Guberg, Kate; Meadows, Sarah; Prentice, Ann; Tian, Lu; Brannon, Patsy M; Lucas, Robyn M; Crump, Peter M; Cavalier, Etienne; Merkel, Joyce; Betz, Joseph M

    2017-09-01

    The Vitamin D Standardization Program (VDSP) coordinated a study in 2012 to assess the commutability of reference materials and proficiency testing/external quality assurance materials for total 25-hydroxyvitamin D [25(OH)D] in human serum, the primary indicator of vitamin D status. A set of 50 single-donor serum samples as well as 17 reference and proficiency testing/external quality assessment materials were analyzed by participating laboratories that used either immunoassay or LC-MS methods for total 25(OH)D. The commutability test materials included National Institute of Standards and Technology Standard Reference Material 972a Vitamin D Metabolites in Human Serum as well as materials from the College of American Pathologists and the Vitamin D External Quality Assessment Scheme. Study protocols and data analysis procedures were in accordance with Clinical and Laboratory Standards Institute guidelines. The majority of the test materials were found to be commutable with the methods used in this commutability study. These results provide guidance for laboratories needing to choose appropriate reference materials and select proficiency or external quality assessment programs and will serve as a foundation for additional VDSP studies.

  6. National and international veterinary reference laboratories for infectious diseases.

    PubMed

    Edwards, S; Alexander, D

    1998-08-01

    Reference laboratories play an increasingly important role in the harmonisation of laboratory diagnostic tests and the standardisation of veterinary vaccines. This is particularly important in building confidence between international trading partners. The authors review aspects of the organisation, designation and support of reference laboratories for infectious diseases of animals and discuss the principal activities which such laboratories would normally perform. These activities include advice and consultancy, publications and communication, training, research, disease surveillance, maintenance of culture collections, evaluation of reference methods, preparation of reference materials and organisation of inter-laboratory comparisons.

  7. Development of a candidate reference material for adventitious virus detection in vaccine and biologicals manufacturing by deep sequencing

    PubMed Central

    Mee, Edward T.; Preston, Mark D.; Minor, Philip D.; Schepelmann, Silke; Huang, Xuening; Nguyen, Jenny; Wall, David; Hargrove, Stacey; Fu, Thomas; Xu, George; Li, Li; Cote, Colette; Delwart, Eric; Li, Linlin; Hewlett, Indira; Simonyan, Vahan; Ragupathy, Viswanath; Alin, Voskanian-Kordi; Mermod, Nicolas; Hill, Christiane; Ottenwälder, Birgit; Richter, Daniel C.; Tehrani, Arman; Jacqueline, Weber-Lehmann; Cassart, Jean-Pol; Letellier, Carine; Vandeputte, Olivier; Ruelle, Jean-Louis; Deyati, Avisek; La Neve, Fabio; Modena, Chiara; Mee, Edward; Schepelmann, Silke; Preston, Mark; Minor, Philip; Eloit, Marc; Muth, Erika; Lamamy, Arnaud; Jagorel, Florence; Cheval, Justine; Anscombe, Catherine; Misra, Raju; Wooldridge, David; Gharbia, Saheer; Rose, Graham; Ng, Siemon H.S.; Charlebois, Robert L.; Gisonni-Lex, Lucy; Mallet, Laurent; Dorange, Fabien; Chiu, Charles; Naccache, Samia; Kellam, Paul; van der Hoek, Lia; Cotten, Matt; Mitchell, Christine; Baier, Brian S.; Sun, Wenping; Malicki, Heather D.

    2016-01-01

    Background Unbiased deep sequencing offers the potential for improved adventitious virus screening in vaccines and biotherapeutics. Successful implementation of such assays will require appropriate control materials to confirm assay performance and sensitivity. Methods A common reference material containing 25 target viruses was produced and 16 laboratories were invited to process it using their preferred adventitious virus detection assay. Results Fifteen laboratories returned results, obtained using a wide range of wet-lab and informatics methods. Six of 25 target viruses were detected by all laboratories, with the remaining viruses detected by 4–14 laboratories. Six non-target viruses were detected by three or more laboratories. Conclusion The study demonstrated that a wide range of methods are currently used for adventitious virus detection screening in biological products by deep sequencing and that they can yield significantly different results. This underscores the need for common reference materials to ensure satisfactory assay performance and enable comparisons between laboratories. PMID:26709640

  8. DOE research and development report. Progress report, October 1980-September 1981

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bingham, Carleton D.

    The DOE New Brunswick Laboratory (NBL) is the US Government's Nuclear Materials Standards and Measurement Laboratory. NBL is assigned the mission to provide and maintain, as an essential part of federal statutory responsibilities related to national and international safeguards of nuclear materials for USA defense and energy programs, an ongoing capability for: the development, preparation, certification, and distribution of reference materials for the calibration and standardization of nuclear materials measurements; the development, improvement, and evaluation of nuclear materials measurement technology; the assessment and evaluation of the practice and application of nuclear materials measurement technology; expert and reliable specialized nuclear materialsmore » measurement services for the government; and technology exchange and training in nuclear materials measurement and standards. Progress reports for this fiscal year are presented under the following sections: (1) development or evaluation of measurement technology (elemental assay of uranium plutonium; isotope composition); (2) standards and reference materials (NBL standards and reference materials; NBS reference materials); and (3) evaluation programs (safeguards analytical laboratory evaluation; general analytical evaluation program; other evaluation programs).« less

  9. Isotope reference materials

    USGS Publications Warehouse

    Coplen, Tyler B.

    2010-01-01

    Measurement of the same isotopically homogeneous sample by any laboratory worldwide should yield the same isotopic composition within analytical uncertainty. International distribution of light element isotopic reference materials by the International Atomic Energy Agency and the U.S. National Institute of Standards and Technology enable laboratories to achieve this goal.

  10. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  11. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  12. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  13. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  14. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  15. The Kjeldahl method as a primary reference procedure for total protein in certified reference materials used in clinical chemistry. II. Selection of direct Kjeldahl analysis and its preliminary performance parameters.

    PubMed

    Vinklárková, Bára; Chromý, Vratislav; Šprongl, Luděk; Bittová, Miroslava; Rikanová, Milena; Ohnútková, Ivana; Žaludová, Lenka

    2015-01-01

    To select a Kjeldahl procedure suitable for the determination of total protein in reference materials used in laboratory medicine, we reviewed in our previous article Kjeldahl methods adopted by clinical chemistry and found an indirect two-step analysis by total Kjeldahl nitrogen corrected for its nonprotein nitrogen and a direct analysis made on isolated protein precipitates. In this article, we compare both procedures on various reference materials. An indirect Kjeldahl method gave falsely lower results than a direct analysis. Preliminary performance parameters qualify the direct Kjeldahl analysis as a suitable primary reference procedure for the certification of total protein in reference laboratories.

  16. Interlaboratory Reproducibility of Droplet Digital Polymerase Chain Reaction Using a New DNA Reference Material Format.

    PubMed

    Pinheiro, Leonardo B; O'Brien, Helen; Druce, Julian; Do, Hongdo; Kay, Pippa; Daniels, Marissa; You, Jingjing; Burke, Daniel; Griffiths, Kate; Emslie, Kerry R

    2017-11-07

    Use of droplet digital PCR technology (ddPCR) is expanding rapidly in the diversity of applications and number of users around the world. Access to relatively simple and affordable commercial ddPCR technology has attracted wide interest in use of this technology as a molecular diagnostic tool. For ddPCR to effectively transition to a molecular diagnostic setting requires processes for method validation and verification and demonstration of reproducible instrument performance. In this study, we describe the development and characterization of a DNA reference material (NMI NA008 High GC reference material) comprising a challenging methylated GC-rich DNA template under a novel 96-well microplate format. A scalable process using high precision acoustic dispensing technology was validated to produce the DNA reference material with a certified reference value expressed in amount of DNA molecules per well. An interlaboratory study, conducted using blinded NA008 High GC reference material to assess reproducibility among seven independent laboratories demonstrated less than 4.5% reproducibility relative standard deviation. With the exclusion of one laboratory, laboratories had appropriate technical competency, fully functional instrumentation, and suitable reagents to perform accurate ddPCR based DNA quantification measurements at the time of the study. The study results confirmed that NA008 High GC reference material is fit for the purpose of being used for quality control of ddPCR systems, consumables, instrumentation, and workflow.

  17. The Joint Committee for Traceability in Laboratory Medicine (JCTLM) - its history and operation.

    PubMed

    Jones, Graham R D; Jackson, Craig

    2016-01-30

    The Joint Committee for Traceability in Laboratory Medicine (JCTLM) was formed to bring together the sciences of metrology, laboratory medicine and laboratory quality management. The aim of this collaboration is to support worldwide comparability and equivalence of measurement results in clinical laboratories for the purpose of improving healthcare. The JCTLM has its origins in the activities of international metrology treaty organizations, professional societies and federations devoted to improving measurement quality in physical, chemical and medical sciences. The three founding organizations, the International Committee for Weights and Measures (CIPM), the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and the International Laboratory Accreditation Cooperation (ILAC) are the leaders of this activity. The main service of the JCTLM is a web-based database with a list of reference materials, reference methods and reference measurement services meeting appropriate international standards. This database allows manufacturers to select references for assay traceability and provides support for suppliers of these services. As of mid 2015 the database lists 295 reference materials for 162 analytes, 170 reference measurement procedures for 79 analytes and 130 reference measurement services for 39 analytes. There remains a need for the development and implementation of metrological traceability in many areas of laboratory medicine and the JCTLM will continue to promote these activities into the future. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. The quality of veterinary in-clinic and reference laboratory biochemical testing.

    PubMed

    Rishniw, Mark; Pion, Paul D; Maher, Tammy

    2012-03-01

    Although evaluation of biochemical analytes in blood is common in veterinary practice, studies assessing the global quality of veterinary in-clinic and reference laboratory testing have not been reported. The aim of this study was to assess the quality of biochemical testing in veterinary laboratories using results obtained from analyses of 3 levels of assayed quality control materials over 5 days. Quality was assessed by comparison of calculated total error with quality requirements, determination of sigma metrics, use of a quality goal index to determine factors contributing to poor performance, and agreement between in-clinic and reference laboratory mean results. The suitability of in-clinic and reference laboratory instruments for statistical quality control was determined using adaptations from the computerized program, EZRules3. Reference laboratories were able to achieve desirable quality requirements more frequently than in-clinic laboratories. Across all 3 materials, > 50% of in-clinic analyzers achieved a sigma metric ≥ 6.0 for measurement of 2 analytes, whereas > 50% of reference laboratory analyzers achieved a sigma metric ≥ 6.0 for measurement of 6 analytes. Expanded uncertainty of measurement and ± total allowable error resulted in the highest mean percentages of analytes demonstrating agreement between in-clinic and reference laboratories. Owing to marked variation in bias and coefficient of variation between analyzers of the same and different types, the percentages of analytes suitable for statistical quality control varied widely. These findings reflect the current state-of-the-art with regard to in-clinic and reference laboratory analyzer performance and provide a baseline for future evaluations of the quality of veterinary laboratory testing. © 2012 American Society for Veterinary Clinical Pathology.

  19. Validation of reference materials for uranium radiochronometry in the frame of nuclear forensic investigations

    DOE PAGES

    Varga, Z.; Mayer, K.; Bonamici, C. E.; ...

    2015-05-11

    The results of a joint effort by expert nuclear forensic laboratories in the area of age dating of uranium, i.e. the elapsed time since the last chemical purification of the material are presented and discussed. Completely separated uranium materials of known production date were distributed among the laboratories, and the samples were dated according to routine laboratory procedures by the measurement of the ²²⁰Th/²³⁴U ratio. The measurement results were in good agreement with the known production date showing that the concept for preparing uranium age dating reference material based on complete separation is valid. Detailed knowledge of the laboratory proceduresmore » used for uranium age dating allows the identification of possible improvements in the current protocols and the development of improved practice in the future. The availability of age dating reference materials as well as the evolvement of the age dating best-practice protocol will increase the relevance and applicability of age dating as part of the tool-kit available for nuclear forensic investigations.« less

  20. Validation of reference materials for uranium radiochronometry in the frame of nuclear forensic investigations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Varga, Z.; Mayer, K.; Bonamici, C. E.

    The results of a joint effort by expert nuclear forensic laboratories in the area of age dating of uranium, i.e. the elapsed time since the last chemical purification of the material are presented and discussed. Completely separated uranium materials of known production date were distributed among the laboratories, and the samples were dated according to routine laboratory procedures by the measurement of the ²²⁰Th/²³⁴U ratio. The measurement results were in good agreement with the known production date showing that the concept for preparing uranium age dating reference material based on complete separation is valid. Detailed knowledge of the laboratory proceduresmore » used for uranium age dating allows the identification of possible improvements in the current protocols and the development of improved practice in the future. The availability of age dating reference materials as well as the evolvement of the age dating best-practice protocol will increase the relevance and applicability of age dating as part of the tool-kit available for nuclear forensic investigations.« less

  1. Development of a reference material for routine performance monitoring of methods measuring polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans and dioxin-like polychlorinated biphenyls.

    PubMed

    Selliah, S S; Cussion, S; MacPherson, K A; Reiner, E J; Toner, D

    2001-06-01

    Matrix-matched environmental certified reference materials (CRMs) are one of the most useful tools to validate analytical methods, assess analytical laboratory performance and to assist in the resolution of data conflicts between laboratories. This paper describes the development of a lake sediment as a CRM for polychorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (DLPCBs). The presence of DLPCBs in the environment is of increased concern and analytical methods are being developed internationally for monitoring DLPCBs in the environment. This paper also reports the results of an international interlaboratory study involving thirty-five laboratories from seventeen countries, conducted to characterize and validate levels of a sediment reference material for PCDDs, PCDFs and DLPCBs.

  2. The use of digital PCR to improve the application of quantitative molecular diagnostic methods for tuberculosis.

    PubMed

    Devonshire, Alison S; O'Sullivan, Denise M; Honeyborne, Isobella; Jones, Gerwyn; Karczmarczyk, Maria; Pavšič, Jernej; Gutteridge, Alice; Milavec, Mojca; Mendoza, Pablo; Schimmel, Heinz; Van Heuverswyn, Fran; Gorton, Rebecca; Cirillo, Daniela Maria; Borroni, Emanuele; Harris, Kathryn; Barnard, Marinus; Heydenrych, Anthenette; Ndusilo, Norah; Wallis, Carole L; Pillay, Keshree; Barry, Thomas; Reddington, Kate; Richter, Elvira; Mozioğlu, Erkan; Akyürek, Sema; Yalçınkaya, Burhanettin; Akgoz, Muslum; Žel, Jana; Foy, Carole A; McHugh, Timothy D; Huggett, Jim F

    2016-08-03

    Real-time PCR (qPCR) based methods, such as the Xpert MTB/RIF, are increasingly being used to diagnose tuberculosis (TB). While qualitative methods are adequate for diagnosis, the therapeutic monitoring of TB patients requires quantitative methods currently performed using smear microscopy. The potential use of quantitative molecular measurements for therapeutic monitoring has been investigated but findings have been variable and inconclusive. The lack of an adequate reference method and reference materials is a barrier to understanding the source of such disagreement. Digital PCR (dPCR) offers the potential for an accurate method for quantification of specific DNA sequences in reference materials which can be used to evaluate quantitative molecular methods for TB treatment monitoring. To assess a novel approach for the development of quality assurance materials we used dPCR to quantify specific DNA sequences in a range of prototype reference materials and evaluated accuracy between different laboratories and instruments. The materials were then also used to evaluate the quantitative performance of qPCR and Xpert MTB/RIF in eight clinical testing laboratories. dPCR was found to provide results in good agreement with the other methods tested and to be highly reproducible between laboratories without calibration even when using different instruments. When the reference materials were analysed with qPCR and Xpert MTB/RIF by clinical laboratories, all laboratories were able to correctly rank the reference materials according to concentration, however there was a marked difference in the measured magnitude. TB is a disease where the quantification of the pathogen could lead to better patient management and qPCR methods offer the potential to rapidly perform such analysis. However, our findings suggest that when precisely characterised materials are used to evaluate qPCR methods, the measurement result variation is too high to determine whether molecular quantification of Mycobacterium tuberculosis would provide a clinically useful readout. The methods described in this study provide a means by which the technical performance of quantitative molecular methods can be evaluated independently of clinical variability to improve accuracy of measurement results. These will assist in ultimately increasing the likelihood that such approaches could be used to improve patient management of TB.

  3. 33 CFR 209.340 - Laboratory investigations and materials testing.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... hydraulic laboratories, and to the Inter-Agency Sedimentation Project. (c) References. (1) AR 37-20. (2) AR... ordinary business channels. (3) Performance of the work will not interfere with provisions of services... with the same procedures as apply to Division Materials Laboratories. (3) Inter-Agency Sedimentation...

  4. 33 CFR 209.340 - Laboratory investigations and materials testing.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... hydraulic laboratories, and to the Inter-Agency Sedimentation Project. (c) References. (1) AR 37-20. (2) AR... ordinary business channels. (3) Performance of the work will not interfere with provisions of services... with the same procedures as apply to Division Materials Laboratories. (3) Inter-Agency Sedimentation...

  5. Preparation of canine C-reactive protein serum reference material: A feasibility study.

    PubMed

    Canalias, Francesca; Piñeiro, Matilde; Pato, Raquel; Peña, Raquel; Bosch, Lluís; Soler, Lourdes; García, Natalia; Lampreave, Fermín; Saco, Yolanda; Bassols, Anna

    2018-03-01

    The availability of a species-specific reference material is essential for the harmonization of results obtained in different laboratories by different methods. We describe the preparation of a canine C-reactive protein (cCRP) serum reference material containing purified cCRP stabilized in a serum matrix. The material can be used by manufacturers to assign values to their calibrator and control materials. The serum matrix was obtained using blood collected from healthy dogs, stabilized and submitted for a delipidation process. The reference material was prepared by diluting purified cCRP in the serum matrix containing 1.0 mol/L HEPES buffer, 3.0 mmol/L calcium chloride, 80,000 kUI/L aprotinin, and 1.0 mmol/L benzamidine hydrochloride monohydrate at a pH of 7.2, and dispensing (0.5 mL) the matrix into vials that were then frozen. The pilot batch of 200 vials was shown to be homogeneous and stable after a stability study at various temperatures and over a total time of 110 days. The prepared material was submitted to an assignment value study. Eight laboratories from different European countries participated by using the same reagents for an immunoturbidimetric method adapted for different analyzers. The obtained cCRP concentration in the reference material was 78.5 mg/L with an expanded uncertainty (k = 2) of 4.2 mg/L. Canine C-reactive protein serum reference material has been produced that allows harmonization of results obtained by different methods and different laboratories, thus reducing the possibility of errors and misunderstandings. © 2018 American Society for Veterinary Clinical Pathology.

  6. New Ca-Tims and La-Icp Analyses of GJ-1, Plesovice, and FC1 Reference Materials

    NASA Astrophysics Data System (ADS)

    Feldman, J. D.; Möller, A.; Walker, J. D.

    2014-12-01

    Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) U-Pb zircon geochronology relies on external reference standards to monitor and correct for different mass fractionation effects and instrument drift. Common zircon reference materials used within the community, including the KU Isotope Geochemistry Laboratory, are GJ-1 (207Pb/206Pb age: 608.53 +/- 0.37Ma; Jackson et al., 2004), Plesovice (337.13 +/- 0.37 Ma; Slama et al., 2008), and FC-1 (1099.0 +/-0.6 Ma; Paces and Miller, 1993). The age distribution of zircon reference material varies slightly from sample fraction to sample fraction, and the published results for GJ-1 are slightly discordant. As a result, using the published data for the distributed standard splits can lead to small systematic variations when comparing datasets from different labs, and more high precision data are needed to evaluate potential inhomogeneity of sample splits used in different laboratories. Here we characterize these reference materials with cathodoluminescence, LA-ICP-MS traverses across grains, and high precision CA-TIMS to better constrain the ages and assess zoning of these standards, and present the data for comparison with other laboratories. Reducing systematic error by dating our own reference material lends confidence to our analyses and allows for inter-laboratory age reproducibility of unknowns. Additionally, the reduction in propagated uncertainties (especially in GJ-1, for which both the red and yellow variety will be analyzed) will be used to improve long-term reproducibility, comparisons between samples of similar age, detrital populations and composite pluton zircons. Jackson, S.E., et al., 2004, Chemical Geology, v. 211, p. 47-69. Paces, J.B. & Miller, J.D., 1993, Journal of Geophysical Research, v. 80, p. 13997-14013. Slama, J., et al., 2008, Chemical Geology, v. 249. p. 1-35.

  7. New Brunswick Laboratory: Progress report, October 1993 through September 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The mission of the New Brunswick Laboratory of the US Department of Energy (DOE) is to serve as the National Certifying Authority for nuclear reference materials and to provide an independent Federal technical staff and laboratory resource performing nuclear material measurement, safeguards and non-proliferation functions in support of multiple program sponsors. During FY 94 New Brunswick Laboratory (NBL) completed development of a Strategic Plan which will aid in better defining performance oriented laboratory goals and objectives in each functional area consistent with the changing needs of the global nuclear community. This annual report describes accomplishments achieved in carrying out NBL`smore » assigned missions. Details of completed projects are reported in separate topical reports or as open-literature publications. Programs discussed here are: (1) safeguards assistance; (2) reference materials program; (3) measurement evaluation; (4) measurement services; and (5) measurement development.« less

  8. Standardization for oxygen isotope ratio measurement - still an unsolved problem.

    PubMed

    Kornexl; Werner; Gehre

    1999-07-01

    Numerous organic and inorganic laboratory standards were gathered from nine European and North American laboratories and were analyzed for their delta(18)O values with a new on-line high temperature pyrolysis system that was calibrated using Vienna standard mean ocean water (VSMOW) and standard light Antartic precipitation (SLAP) internationally distributed reference water samples. Especially for organic materials, discrepancies between reported and measured values were high, ranging up to 2 per thousand. The reasons for these discrepancies are discussed and the need for an exact and reliable calibration of existing reference materials, as well as for the establishment of additional organic and inorganic reference materials is stressed. Copyright 1999 John Wiley & Sons, Ltd.

  9. Homogeneity study of a corn flour laboratory reference material candidate for inorganic analysis.

    PubMed

    Dos Santos, Ana Maria Pinto; Dos Santos, Liz Oliveira; Brandao, Geovani Cardoso; Leao, Danilo Junqueira; Bernedo, Alfredo Victor Bellido; Lopes, Ricardo Tadeu; Lemos, Valfredo Azevedo

    2015-07-01

    In this work, a homogeneity study of a corn flour reference material candidate for inorganic analysis is presented. Seven kilograms of corn flour were used to prepare the material, which was distributed among 100 bottles. The elements Ca, K, Mg, P, Zn, Cu, Fe, Mn and Mo were quantified by inductively coupled plasma optical emission spectrometry (ICP OES) after acid digestion procedure. The method accuracy was confirmed by analyzing the rice flour certified reference material, NIST 1568a. All results were evaluated by analysis of variance (ANOVA) and principal component analysis (PCA). In the study, a sample mass of 400mg was established as the minimum mass required for analysis, according to the PCA. The between-bottle test was performed by analyzing 9 bottles of the material. Subsamples of a single bottle were analyzed for the within-bottle test. No significant differences were observed for the results obtained through the application of both statistical methods. This fact demonstrates that the material is homogeneous for use as a laboratory reference material. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. The Kjeldahl method as a primary reference procedure for total protein in certified reference materials used in clinical chemistry. I. A review of Kjeldahl methods adopted by laboratory medicine.

    PubMed

    Chromý, Vratislav; Vinklárková, Bára; Šprongl, Luděk; Bittová, Miroslava

    2015-01-01

    We found previously that albumin-calibrated total protein in certified reference materials causes unacceptable positive bias in analysis of human sera. The simplest way to cure this defect is the use of human-based serum/plasma standards calibrated by the Kjeldahl method. Such standards, commutative with serum samples, will compensate for bias caused by lipids and bilirubin in most human sera. To find a suitable primary reference procedure for total protein in reference materials, we reviewed Kjeldahl methods adopted by laboratory medicine. We found two methods recommended for total protein in human samples: an indirect analysis based on total Kjeldahl nitrogen corrected for its nonprotein nitrogen and a direct analysis made on isolated protein precipitates. The methods found will be assessed in a subsequent article.

  11. 21 CFR 211.194 - Laboratory records.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... specific component, drug product container, closure, in-process material, or drug product, and lot tested... product container, closure, in-process material, or drug product tested. (7) The initials or signature of... of any testing and standardization of laboratory reference standards, reagents, and standard...

  12. The characterization and certification of a quantitative reference material for Legionella detection and quantification by qPCR.

    PubMed

    Baume, M; Garrelly, L; Facon, J P; Bouton, S; Fraisse, P O; Yardin, C; Reyrolle, M; Jarraud, S

    2013-06-01

    The characterization and certification of a Legionella DNA quantitative reference material as a primary measurement standard for Legionella qPCR. Twelve laboratories participated in a collaborative certification campaign. A candidate reference DNA material was analysed through PCR-based limiting dilution assays (LDAs). The validated data were used to statistically assign both a reference value and an associated uncertainty to the reference material. This LDA method allowed for the direct quantification of the amount of Legionella DNA per tube in genomic units (GU) and the determination of the associated uncertainties. This method could be used for the certification of all types of microbiological standards for qPCR. The use of this primary standard will improve the accuracy of Legionella qPCR measurements and the overall consistency of these measurements among different laboratories. The extensive use of this certified reference material (CRM) has been integrated in the French standard NF T90-471 (April 2010) and in the ISO Technical Specification 12 869 (Anon 2012 International Standardisation Organisation) for validating qPCR methods and ensuring the reliability of these methods. © 2013 The Society for Applied Microbiology.

  13. Certified reference materials for testing of the presence/absence of Staphylococcus aureus enterotoxin A (SEA) in cheese.

    PubMed

    Zeleny, Reinhard; Nia, Yacine; Schimmel, Heinz; Mutel, Isabelle; Hennekinne, Jacques-Antoine; Emteborg, Håkan; Charoud-Got, Jean; Auvray, Frédéric

    2016-08-01

    Staphylococcal enterotoxins (SEs) account for a substantial number of food-poisoning outbreaks. European legislation (Commission Regulation 1441/2007) stipulates the reference procedure for SE analysis in milk and dairy products, which is based on extraction, dialysis concentration and immunochemical detection using one of two approved assays (VIDAS(®) SET2, Ridascreen(®) SET Total). However, certified reference materials (CRMs) are lacking to support laboratories in performing reliable detection of Staphylococcus aureus enterotoxin A (SEA) in relevant matrices at sub-nanogram per gram levels. The certification of a set of three reference materials (blank and two SEA-containing materials) for testing of the presence/absence of SEA in cheese is described. The reference procedure was applied in an intercomparison with 15 laboratories, and results were reported in a qualitative manner (presence or absence of SEA in the sample). No false-negative or false-positive results were obtained. The certified values were stated as diagnostic specificity (blank material) or diagnostic sensitivity (SEA-containing materials) and were 100 % in all cases. Stability studies demonstrated suitable material stability when stored cooled or frozen. An in-house study on the recovery of SEA in the cheese materials using a double-sandwich enzyme-linked immunosorbent assay (ELISA) revealed comparable recovery values of around 45 % at the two spiking levels and in both the SEA-containing CRMs as well as blank CRM freshly spiked prior to analysis. The values were also comparable over time and among different analysts. The materials provide valuable support to laboratories for method validation and method performance verification and will increase the reliability of measuring SEA in cheese.

  14. 46 CFR 164.013-2 - Incorporation by reference.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    .... All approved material incorporated by reference may be inspected at the National Archives and Records... Fire Safety Division, U.S. Coast Guard Stop 7509, 2703 Martin Luther King Jr. Avenue SE., Washington...: Underwriters Laboratories (UL) Underwriters Laboratories, Inc., P.O. Box 13995, Research Triangle Park, NC...

  15. 46 CFR 164.013-2 - Incorporation by reference.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    .... All approved material incorporated by reference may be inspected at the National Archives and Records... Fire Safety Division, U.S. Coast Guard Stop 7509, 2703 Martin Luther King Jr. Avenue SE., Washington...: Underwriters Laboratories (UL) Underwriters Laboratories, Inc., P.O. Box 13995, Research Triangle Park, NC...

  16. An assessment of contemporary atomic spectroscopic techniques for the determination of lead in blood and urine matrices

    NASA Astrophysics Data System (ADS)

    Parsons, Patrick J.; Geraghty, Ciaran; Verostek, Mary Frances

    2001-09-01

    The preparation and validation of a number of clinical reference materials for the determination of lead in blood and urine is described. Four candidate blood lead reference materials (Lots, 047-050), and four candidate urine lead reference materials (Lots, 034, 035, 037 and 038), containing physiologically-bound lead at clinically relevant concentrations, were circulated to up to 21 selected laboratories specializing in this analysis. Results from two interlaboratory studies were used to establish certified values and uncertainty estimates for these reference materials. These data also provided an assessment of current laboratory techniques for the measurement of lead in blood and urine. For the blood lead measurements, four laboratories used electrothermal atomization AAS, three used anodic stripping voltammetry and one used both ETAAS and ICP-MS. For the urine lead measurements, 11 laboratories used ETAAS (most with Zeeman background correction) and 10 used ICP-MS. Certified blood lead concentrations, ±S.D., ranged from 5.9±0.4 μg/dl (0.28±0.02 μmol/l) to 76.0±2.2 μg/dl (3.67±0.11 μmol/l) and urine lead concentrations ranged from 98±5 μg/l (0.47±0.02 μmol/l) to 641±36 μg/l (3.09±0.17 μmol/l). The highest concentration blood lead material was subjected to multiple analyses using ETAAS over an extended time period. The data indicate that more stringent internal quality control practices are necessary to improve long-term precision. While the certification of blood lead materials was accomplished in a manner consistent with established practices, the urine lead materials proved more troublesome, particularly at concentrations above 600 μg/l (2.90 μmol/l).

  17. HOW OLD IS IT? - 241PU/241AM NUCLEAR FORENSIC CHRONOLOGY REFERENCE MATERIALS

    PubMed Central

    Fitzgerald, Ryan; Inn, Kenneth G.W.; Horgan, Christopher

    2018-01-01

    One material attribute for nuclear forensics is material age. 241Pu is almost always present in uranium- and plutonium-based nuclear weapons, which pose the greatest threat to our security. The in-growth of 241Am due to the decay of 241Pu provides an excellent chronometer of the material. A well-characterized 241Pu/241Am standard is needed to validate measurement capability, as a basis for between-laboratory comparability, and as material for verifying laboratory performance. This effort verifies the certification of a 38 year old 241Pu Standard Reference Material (SRM4340) through alpha-gamma anticoincidence counting, and also establishes the separation date to two weeks of the documented date. PMID:29720779

  18. 46 CFR 164.013-2 - Incorporation by reference.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    .... All approved material incorporated by reference may be inspected at the National Archives and Records Administration (NARA), and at the U.S. Coast Guard, Lifesaving and Fire Safety Division (CG-ENG-4), 2100 2nd St... as follows: Underwriters Laboratories (UL) Underwriters Laboratories, Inc., P.O. Box 13995, Research...

  19. [Report of the NEDO project "Research and development to promote the creation and utilization of an intellectual infrastructure: development of reference materials for laboratory medicine" "Development of pure substance-type certified reference materials"].

    PubMed

    Takatsu, Akiko

    2009-06-01

    There is an increasing demand to establish a metrological traceability system for in vitro diagnostics and medical devices. Pure substance-type reference materials are playing key roles in metrological traceability, because they form the basis for many traceability chains in chemistry. The National Metrology Institute of Japan (NMIJ), in the National Institute of Advanced Industrial Science and Technology (AIST), has been developing purity-certified reference materials (CRMs) in this field, such as cholesterol, creatinine, and urea. In the New Energy and Industrial Technology Development Organization (NEDO) project, entitled: "Research and Development to Promote the Creation and Utilization of an Intellectual Infrastructure: Development of Reference Materials for Laboratory Medicine", several pure substance-type CRMs were developed. For a pure protein solution CRM, amino acid analysis and nitrogen determination were chosen as the certification methods. The development and certification processes for the C-reactive protein (CRP) solution CRM were completed, with the recombinant human CRP solution as a candidate material. This CRP solution CRM is now available as NMIJ CRM. For cortisol CRM, a purified candidate material and highly pure primary reference material were prepared. Each impure compound in the materials was identified and quantified. The pure cortisol CRM will be available in 2009. These two CRMs provide a traceability link between routine clinical methods and the SI unit.

  20. European Proficiency testing of national reference laboratories for the confirmation of sulfonamide residues in muscle and milk.

    PubMed

    Juhel-Gaugain, Murielle; Fourmond, Marie-Pierre; Delepine, Bernard; Laurentie, Michel; Brigitte, Roudaut; Sanders, Pascal

    2005-03-01

    Two interlaboratory studies were organized in 2002-2003 in order to check the proficiency of laboratories in confirming the presence of sulfonamide residues in muscle and milk. These studies involved 25 EU National Reference Laboratories (NRLs) from 21 different European Countries in charge of statutory monitoring of antimicrobial residues in food of animal origin at a national level. The study was conducted according to international and national guidelines by the Community Reference Laboratory (CRL) in charge of antimicrobial substances. Four different test matrices of sheep muscle and four different test matrices of bovine milk containing different sulfonamide substances were prepared and sent to the participants. Each participant was asked to use his own routine confirmatory method and to analyse each sample in triplicate within a period of about six weeks during which the stability of the materials was checked by the organizer. The sulfonamide content of each material was determined by calculating the robust means of all the results and the deviation of the results from the assigned values was assessed by calculating Z-scores. Overall, results were satisfactory, particularly considering that it was the first proficiency test dealing with sulfonamides organised by the Community Reference Laboratory.

  1. Characterization of 107 Genomic DNA Reference Materials for CYP2D6, CYP2C19, CYP2C9, VKORC1, and UGT1A1

    PubMed Central

    Pratt, Victoria M.; Zehnbauer, Barbara; Wilson, Jean Amos; Baak, Ruth; Babic, Nikolina; Bettinotti, Maria; Buller, Arlene; Butz, Ken; Campbell, Matthew; Civalier, Chris; El-Badry, Abdalla; Farkas, Daniel H.; Lyon, Elaine; Mandal, Saptarshi; McKinney, Jason; Muralidharan, Kasinathan; Noll, LeAnne; Sander, Tara; Shabbeer, Junaid; Smith, Chingying; Telatar, Milhan; Toji, Lorraine; Vairavan, Anand; Vance, Carlos; Weck, Karen E.; Wu, Alan H.B.; Yeo, Kiang-Teck J.; Zeller, Markus; Kalman, Lisa

    2010-01-01

    Pharmacogenetic testing is becoming more common; however, very few quality control and other reference materials that cover alleles commonly included in such assays are currently available. To address these needs, the Centers for Disease Control and Prevention's Genetic Testing Reference Material Coordination Program, in collaboration with members of the pharmacogenetic testing community and the Coriell Cell Repositories, have characterized a panel of 107 genomic DNA reference materials for five loci (CYP2D6, CYP2C19, CYP2C9, VKORC1, and UGT1A1) that are commonly included in pharmacogenetic testing panels and proficiency testing surveys. Genomic DNA from publicly available cell lines was sent to volunteer laboratories for genotyping. Each sample was tested in three to six laboratories using a variety of commercially available or laboratory-developed platforms. The results were consistent among laboratories, with differences in allele assignments largely related to the manufacturer's assay design and variable nomenclature, especially for CYP2D6. The alleles included in the assay platforms varied, but most were identified in the set of 107 DNA samples. Nine additional pharmacogenetic loci (CYP4F2, EPHX1, ABCB1, HLAB, KIF6, CYP3A4, CYP3A5, TPMT, and DPD) were also tested. These samples are publicly available from Coriell and will be useful for quality assurance, proficiency testing, test development, and research. PMID:20889555

  2. Nuclear reference materials to meet the changing needs of the global nuclear community

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, H.R.; Gradle, C.G.; Narayanan, U.I.

    New Brunswick Laboratory (NBL) serves as the U.S. Government`s certifying authority for nuclear reference materials and measurement calibration standards. In this role, NBL provides nuclear reference materials certified for chemical and/or isotopic compositions traceable to a nationally accepted, internationally compatible reference base. Emphasis is now changing as to the types of traceable nuclear reference materials needed as operations change within the Department of Energy complex and at nuclear facilities around the world. New challenges include: environmental and waste minimization issues, facilities and materials transitioning from processing to storage modes with corresponding changes in the types of measurements being performed, emphasismore » on requirements for characterization of waste materials, and difficulties in transporting nuclear materials and international factors, including IAEA influences. During these changing times, it is critical that traceable reference materials be provided for calibration or validation of the performance of measurement systems. This paper will describe actions taken and planned to meet the changing reference material needs of the global nuclear community.« less

  3. Harmonization in laboratory medicine: Requests, samples, measurements and reports.

    PubMed

    Plebani, Mario

    2016-01-01

    In laboratory medicine, the terms "standardization" and "harmonization" are frequently used interchangeably as the final goal is the same: the equivalence of measurement results among different routine measurement procedures over time and space according to defined analytical and clinical quality specifications. However, the terms define two distinct, albeit closely linked, concepts based on traceability principles. The word "standardization" is used when results for a measurement are equivalent and traceable to the International System of Units (SI) through a high-order primary reference material and/or a reference measurement procedure (RMP). "Harmonization" is generally used when results are equivalent, but neither a high-order primary reference material nor a reference measurement procedure is available. Harmonization is a fundamental aspect of quality in laboratory medicine as its ultimate goal is to improve patient outcomes through the provision of accurate and actionable laboratory information. Patients, clinicians and other healthcare professionals assume that clinical laboratory tests performed by different laboratories at different times on the same sample and specimen can be compared, and that results can be reliably and consistently interpreted. Unfortunately, this is not necessarily the case, because many laboratory test results are still highly variable and poorly standardized and harmonized. Although the initial focus was mainly on harmonizing and standardizing analytical processes and methods, the scope of harmonization now also includes all other aspects of the total testing process (TTP), such as terminology and units, report formats, reference intervals and decision limits as well as tests and test profiles, requests and criteria for interpretation. Several projects and initiatives aiming to improve standardization and harmonization in the testing process are now underway. Laboratory professionals should therefore step up their efforts to provide interchangeable and comparable laboratory information in order to ultimately assure better diagnosis and treatment in patient care.

  4. Constraints on transportation of reagents, reference materials and samples, difficulties and possible solutions: a user's perspective.

    PubMed

    Blanchard, P C

    2006-01-01

    The air transportation of infectious materials is regulated by international air transport associations and based on United Nations Model regulations which have become more practical in addressing animal disease agents. However, individual countries' import and interstate requirements determine what materials can be imported and transported, and this approval process can be long, resulting in delays in organism confirmation, use of international OIE and other reference laboratories, and acquisition of reference materials, proficiency test panels, and reagents for performing necessary testing. Delays can be prevented for permits that are required for the routine work performed by a laboratory through the use of comprehensive and annually renewed permits. This process, however, does not address new and exotic agents where time is critical to an effective emergency response. This paper suggests actions by both the OIE and regulatory authorities which can assist in streamlining and expediting the permit process.

  5. Field Demonstration and Validation of a New Device for Measuring Water and Solute Fluxes at CFB Borden

    DTIC Science & Technology

    2006-11-01

    All Quality Control Reference Materials are acquired only from authorized vendors or sources commonly used by U.S. EPA Regional Laboratories...Institue of Standards and Testing (NITS) Standard Reference Materials (SRM) or to the U.S. EPA Reference Standards. Working Standards The commercial...contaminants from clothing or equipment by blowing, shaking or any other means that may disperse material into the air is prohibited. 7.1.3. All disposable

  6. [Development of the certified reference material of mercury in lyophilized human urine].

    PubMed

    Zhao, Wei; Zhang, Fu-gang; DU, Hui-fang; Pan, Ya-juan; Yan, Hui-fang

    2011-02-01

    To develop the certified reference material of mercury in lyophilized human urine. Human urine samples from normal level mercury districts were filtered, homogenized, dispensed, lyophilized and radio-sterilized. Homogeneity test, stability inspection and certification were conducted using a atom fluorescence spectrophotometric method. The physical and chemical stability of the certified reference material were assessed for 18 months. The certified values are based on analysis made by three independent laboratories. The certified values are as follows: low level was (35.6 ± 2.1) µg/L, high level was (50.5 ± 3.0) µg/L. The certified reference material of mercury in lyophilized human urine in this research reached the national certified reference material requirements and could be used for the quality control.

  7. A new isotopic reference material for stable hydrogen and oxygen isotope-ratio measurements of water—USGS50 Lake Kyoga Water

    USGS Publications Warehouse

    Coplen, Tyler B.; Wassenaar, Leonard I; Mukwaya, Christine; Qi, Haiping; Lorenz, Jennifer M.

    2015-01-01

    This isotopic reference material, designated as USGS50, is intended as one of two reference waters for daily normalization of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer, of use especially for isotope-hydrology laboratories analyzing freshwater samples from equatorial and tropical regions.

  8. Nicotine, acetanilide and urea multi-level2H-,13C- and15N-abundance reference materials for continuous-flow isotope ratio mass spectrometry

    USGS Publications Warehouse

    Schimmelmann, A.; Albertino, A.; Sauer, P.E.; Qi, H.; Molinie, R.; Mesnard, F.

    2009-01-01

    Accurate determinations of stable isotope ratios require a calibration using at least two reference materials with different isotopic compositions to anchor the isotopic scale and compensate for differences in machine slope. Ideally, the S values of these reference materials should bracket the isotopic range of samples with unknown S values. While the practice of analyzing two isotopically distinct reference materials is common for water (VSMOW-SLAP) and carbonates (NBS 19 and L-SVEC), the lack of widely available organic reference materials with distinct isotopic composition has hindered the practice when analyzing organic materials by elemental analysis/isotope ratio mass spectrometry (EA-IRMS). At present only L-glutamic acids USGS40 and USGS41 satisfy these requirements for ??13C and ??13N, with the limitation that L-glutamic acid is not suitable for analysis by gas chromatography (GC). We describe the development and quality testing of (i) four nicotine laboratory reference materials for on-line (i.e. continuous flow) hydrogen reductive gas chromatography-isotope ratio mass-spectrometry (GC-IRMS), (ii) five nicotines for oxidative C, N gas chromatography-combustion-isotope ratio mass-spectrometry (GC-C-IRMS, or GC-IRMS), and (iii) also three acetanilide and three urea reference materials for on-line oxidative EA-IRMS for C and N. Isotopic off-line calibration against international stable isotope measurement standards at Indiana University adhered to the 'principle of identical treatment'. The new reference materials cover the following isotopic ranges: ??2Hnicotine -162 to -45%o, ??13Cnicotine -30.05 to +7.72%, ?? 15Nnicotine -6.03 to +33.62%; ??15N acetanilide +1-18 to +40.57%; ??13Curea -34.13 to +11.71%, ??15Nurea +0.26 to +40.61% (recommended ?? values refer to calibration with NBS 19, L-SVEC, IAEA-N-1, and IAEA-N-2). Nicotines fill a gap as the first organic nitrogen stable isotope reference materials for GC-IRMS that are available with different ??13N values. Comparative ??13C and ??15N on-line EA-IRMS data from 14 volunteering laboratories document the usefulness and reliability of acetanilides and ureas as EA-IRMS reference materials.

  9. Integrated Data Collection Analysis (IDCA) Program - RDX Type II Class 5 Standard, Data Set 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.

    This document describes the results of the first reference sample material—RDX Type II Class 5—examined in the proficiency study for small-scale safety and thermal (SSST) testing of explosive materials for the Integrated Data Collection Analysis (IDCA) Program. The IDCA program is conducting proficiency testing on homemade explosives (HMEs). The reference sample materials are being studied to establish the accuracy of traditional explosives safety testing for each performing laboratory. These results will be used for comparison to results from testing HMEs. This effort, funded by the Department of Homeland Security (DHS), ultimately will put the issues of safe handling of thesemore » materials in perspective with standard military explosives. The results of the study will add SSST testing results for a broad suite of different HMEs to the literature, potentially suggest new guidelines and methods for HME testing, and possibly establish what are the needed accuracies in SSST testing to develop safe handling practices. Described here are the results for impact, friction, electrostatic discharge, and scanning calorimetry analysis of a reference sample of RDX Type II Class 5. The results from each participating testing laboratory are compared using identical test material and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. These results are then compared to historical data from various sources. The performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Air Force Research Laboratory/ RXQL (AFRL), Indian Head Division, Naval Surface Warfare Center, (IHD-NSWC), and Sandia National Laboratories (SNL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to understand how to compare results when test protocols are not identical.« less

  10. External quality assurance programs as a tool for verifying standardization of measurement procedures: Pilot collaboration in Europe.

    PubMed

    Perich, C; Ricós, C; Alvarez, V; Biosca, C; Boned, B; Cava, F; Doménech, M V; Fernández-Calle, P; Fernández-Fernández, P; García-Lario, J V; Minchinela, J; Simón, M; Jansen, R

    2014-05-15

    Current external quality assurance schemes have been classified into six categories, according to their ability to verify the degree of standardization of the participating measurement procedures. SKML (Netherlands) is a Category 1 EQA scheme (commutable EQA materials with values assigned by reference methods), whereas SEQC (Spain) is a Category 5 scheme (replicate analyses of non-commutable materials with no values assigned by reference methods). The results obtained by a group of Spanish laboratories participating in a pilot study organized by SKML are examined, with the aim of pointing out the improvements over our current scheme that a Category 1 program could provide. Imprecision and bias are calculated for each analyte and laboratory, and compared with quality specifications derived from biological variation. Of the 26 analytes studied, 9 had results comparable with those from reference methods, and 10 analytes did not have comparable results. The remaining 7 analytes measured did not have available reference method values, and in these cases, comparison with the peer group showed comparable results. The reasons for disagreement in the second group can be summarized as: use of non-standard methods (IFCC without exogenous pyridoxal phosphate for AST and ALT, Jaffé kinetic at low-normal creatinine concentrations and with eGFR); non-commutability of the reference material used to assign values to the routine calibrator (calcium, magnesium and sodium); use of reference materials without established commutability instead of reference methods for AST and GGT, and lack of a systematic effort by manufacturers to harmonize results. Results obtained in this work demonstrate the important role of external quality assurance programs using commutable materials with values assigned by reference methods to correctly monitor the standardization of laboratory tests with consequent minimization of risk to patients. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Field Demonstration and Validation of a New Device for Measuring Water and Solute Fluxes at Naval Base Ventura County (NBVC), Port Hueneme, CA

    DTIC Science & Technology

    2006-07-01

    All Quality Control Reference Materials are acquired only from authorized vendors or sources commonly used by U.S. EPA Regional Laboratories...are traceable to the National Institue of Standards and Testing (NITS) Standard Reference Materials (SRM) or to the U.S. EPA Reference Standards... clothing or equipment by blowing, shaking or any other means that may disperse material into the air is prohibited. 7.1.3. All disposable personal

  12. New Brunswick Laboratory progress report, October 1994--September 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The mission of the New Brunswick Laboratory (NBL) of the A. S. Department of Energy (DOE) is to serve as the National Certifying Authority for nuclear reference materials and to provide an independent Federal technical staff and laboratory resource performing nuclear material measurement, safeguards, and non-proliferation functions in support of multiple program sponsors. This annual report describes accomplishments achieved in carrying out NBL`s assigned missions.

  13. Nuclear reference materials to meet the changing needs of the global nuclear community

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, H.R.; Gradle, C.G.; Narayanan, U.I.

    New Brunswick Laboratory (NBL) serves as the US Government`s Certifying Authority for nuclear reference materials and measurement calibration standards. In this role, NBL provides nuclear reference materials certified for chemical and/or isotopic compositions traceable to a nationally accepted, internationally compatible reference base. Emphasis is now changing as to the types of traceable nuclear reference materials needed as operations change within the Department of Energy (DOE) complex and at nuclear facilities around the world. Environmental and waste minimization issues, facilities and materials transitioning from processing to storage modes with corresponding changes in the types of measurements being performed, emphasis on requirementsmore » for characterization of waste materials, difficulties in transporting nuclear materials, and International factors, including International Atomic Energy Agency (IAEA) inspection of excess US nuclear materials, are all contributing influences. During these changing times, ft is critical that traceable reference materials be provided for calibration or validation of the performance of measurement systems. This paper will describe actions taken and planned to meet the changing reference material needs of the global nuclear community.« less

  14. Determination of perfluorinated alkyl acid concentrations in human serum and milk standard reference materials.

    PubMed

    Keller, Jennifer M; Calafat, Antonia M; Kato, Kayoko; Ellefson, Mark E; Reagen, William K; Strynar, Mark; O'Connell, Steven; Butt, Craig M; Mabury, Scott A; Small, Jeff; Muir, Derek C G; Leigh, Stefan D; Schantz, Michele M

    2010-05-01

    Standard Reference Materials (SRMs) are certified reference materials produced by the National Institute of Standards and Technology that are homogeneous materials well characterized with values for specified properties, such as environmental contaminant concentrations. They can be used to validate measurement methods and are critical in improving data quality. Disagreements in perfluorinated alkyl acid (PFAA) concentrations measured in environmental matrices during past interlaboratory comparisons emphasized the need for SRMs with values assigned for PFAAs. We performed a new interlaboratory comparison among six laboratories and provided, for the first time, value assignment of PFAAs in SRMs. Concentrations for perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA), and other PFAAs in two human serum and two human milk SRMs are reported. PFAA concentration measurements agreed for serum SRM 1957 using different analytical methods in six laboratories and for milk SRM 1954 in three laboratories. The interlaboratory relative standard deviation for PFOS in SRM 1957 was 7%, which is an improvement over past interlaboratory studies. Matrix interferences are discussed, as well as temporal trends and the percentage of branched vs. linear isomers. The concentrations in these SRMs are similar to the present-day average concentrations measured in human serum and milk, resulting in representative and useful control materials for PFAA human monitoring studies.

  15. Use of gelatin gels as a reference material for performance evaluation of meat shear force measurements

    USDA-ARS?s Scientific Manuscript database

    Establishing standards for meat tenderness based on Warner-Bratzler shear force (WBSF) is complicated by the lack of methods for certifying WBSF testing among texture systems or laboratories. The objective of this study was to determine the suitability of using gelatin gels as a reference material ...

  16. 46 CFR 160.076-11 - Incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Laboratories, Inc., 12 Laboratory Drive, Research Triangle Park, NC 27709-3995 (Phone (919) 549-1400; Facsimile... affected are as follows: American Society for Testing and Materials (ASTM) 100 Barr Harbor Drive, West...

  17. Preparation and Certification of Two New Bulk Welding Fume Reference Materials for Use in Laboratories Undertaking Analysis of Occupational Hygiene Samples

    PubMed Central

    Butler, Owen; Musgrove, Darren; Stacey, Peter

    2014-01-01

    Workers can be exposed to fume, arising from welding activities, which contain toxic metals and metalloids. Occupational hygienists need to assess and ultimately minimize such exposure risks. The monitoring of the concentration of particles in workplace air is one assessment approach whereby fume, from representative welding activities, is sampled onto a filter and returned to a laboratory for analysis. Inductively coupled plasma-atomic emission spectrometry and inductively coupled plasma-mass spectrometry are generally employed as instrumental techniques of choice for the analysis of such filter samples. An inherent difficulty, however, with inductively coupled plasma-based analytical techniques is that they typically require a sample to be presented for analysis in the form of a solution. The efficiency of the required dissolution step relies heavily upon the skill and experience of the analyst involved. A useful tool in assessing the efficacy of this dissolution step would be the availability and subsequent analysis of welding fume reference materials with stated elemental concentrations and matrices that match as closely as possible the matrix composition of welding fume samples submitted to laboratories for analysis. This article describes work undertaken at the Health and Safety Laboratory to prepare and certify two new bulk welding fume reference materials that can be routinely used by analysts to assess the performance of the digestion procedures they employ in their laboratories. PMID:24499055

  18. Preparation and certification of two new bulk welding fume reference materials for use in laboratories undertaking analysis of occupational hygiene samples.

    PubMed

    Butler, Owen; Musgrove, Darren; Stacey, Peter

    2014-01-01

    Workers can be exposed to fume, arising from welding activities, which contain toxic metals and metalloids. Occupational hygienists need to assess and ultimately minimize such exposure risks. The monitoring of the concentration of particles in workplace air is one assessment approach whereby fume, from representative welding activities, is sampled onto a filter and returned to a laboratory for analysis. Inductively coupled plasma-atomic emission spectrometry and inductively coupled plasma-mass spectrometry are generally employed as instrumental techniques of choice for the analysis of such filter samples. An inherent difficulty, however, with inductively coupled plasma-based analytical techniques is that they typically require a sample to be presented for analysis in the form of a solution. The efficiency of the required dissolution step relies heavily upon the skill and experience of the analyst involved. A useful tool in assessing the efficacy of this dissolution step would be the availability and subsequent analysis of welding fume reference materials with stated elemental concentrations and matrices that match as closely as possible the matrix composition of welding fume samples submitted to laboratories for analysis. This article describes work undertaken at the Health and Safety Laboratory to prepare and certify two new bulk welding fume reference materials that can be routinely used by analysts to assess the performance of the digestion procedures they employ in their laboratories.

  19. Instructional Materials Available from Agricultural Education Teaching Materials Center, College Station, Texas. Price List No. 1.

    ERIC Educational Resources Information Center

    Agricultural Education Teaching Materials Center, College Station, TX.

    Price lists and order forms are provided for courses of study, lesson plans, and laboratory exercises for vocational agriculture cooperative education and preemployment laboratory training. Courses of study and required references are listed for training employees for: (1) milk, meat, and poultry processing, (2) poultry hatcheries, (3) dairy…

  20. Uncertainty evaluation in normalization of isotope delta measurement results against international reference materials.

    PubMed

    Meija, Juris; Chartrand, Michelle M G

    2018-01-01

    Isotope delta measurements are normalized against international reference standards. Although multi-point normalization is becoming a standard practice, the existing uncertainty evaluation practices are either undocumented or are incomplete. For multi-point normalization, we present errors-in-variables regression models for explicit accounting of the measurement uncertainty of the international standards along with the uncertainty that is attributed to their assigned values. This manuscript presents framework to account for the uncertainty that arises due to a small number of replicate measurements and discusses multi-laboratory data reduction while accounting for inevitable correlations between the laboratories due to the use of identical reference materials for calibration. Both frequentist and Bayesian methods of uncertainty analysis are discussed.

  1. The production and certification of a plutonium equal-atom reference material: NBL CRM 128

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crawford, D.W.; Gradle, C.G.; Soriano, M.D.

    This report describes the design, production, and certification of the New Brunswick Laboratory plutonium equal-atom certified reference material (CRM), NBL CRM 128. The primary use of this CRM is for the determination of bias corrections encountered in the operation of a mass spectrometer. This reference material is available to the US Department of Energy contractor-operated and government-operated laboratories, as well as to the international nuclear safeguards community. The absolute, or unbiased, certified value for the CRM's Pu-242/Pu-239 ratio is 1.00063 {plus minus} 0.00026 (95% confidence interval) as of October 1, 1984. This value was obtained through the quantitative blending ofmore » high-purity, chemically and isotopically characterized separated isotopes, as well as through intercomparisons of CRM samples with calibration mixtures using thermal ionization mass spectrometry. 32 tabs.« less

  2. Sediment laboratory quality-assurance project: studies of methods and materials

    USGS Publications Warehouse

    Gordon, J.D.; Newland, C.A.; Gray, J.R.

    2001-01-01

    In August 1996 the U.S. Geological Survey initiated the Sediment Laboratory Quality-Assurance project. The Sediment Laboratory Quality Assurance project is part of the National Sediment Laboratory Quality-Assurance program. This paper addresses the fmdings of the sand/fme separation analysis completed for the single-blind reference sediment-sample project and differences in reported results between two different analytical procedures. From the results it is evident that an incomplete separation of fme- and sand-size material commonly occurs resulting in the classification of some of the fme-size material as sand-size material. Electron microscopy analysis supported the hypothesis that the negative bias for fme-size material and the positive bias for sand-size material is largely due to aggregation of some of the fine-size material into sand-size particles and adherence of fine-size material to the sand-size grains. Electron microscopy analysis showed that preserved river water, which was low in dissolved solids, specific conductance, and neutral pH, showed less aggregation and adhesion than preserved river water that was higher in dissolved solids and specific conductance with a basic pH. Bacteria were also found growing in the matrix, which may enhance fme-size material aggregation through their adhesive properties. Differences between sediment-analysis methods were also investigated as pan of this study. Suspended-sediment concentration results obtained from one participating laboratory that used a total-suspended solids (TSS) method had greater variability and larger negative biases than results obtained when this laboratory used a suspended-sediment concentration method. When TSS methods were used to analyze the reference samples, the median suspended sediment concentration percent difference was -18.04 percent. When the laboratory used a suspended-sediment concentration method, the median suspended-sediment concentration percent difference was -2.74 percent. The percent difference was calculated as follows: Percent difference = (( reported mass - known mass)/known mass ) X 100.

  3. Characterization of NIES CRM No. 23 Tea Leaves II for the determination of multielements.

    PubMed

    Mori, Ikuko; Ukachi, Miyuki; Nagano, Kimiyo; Ito, Hiroyasu; Yoshinaga, Jun; Nishikawa, Masataka

    2010-05-01

    A candidate environmental certified reference material (CRM) for the determination of multielements in tea leaves and materials of similar matrix, NIES CRM No. 23 Tea Leaves II, has been developed and characterized by the National Institute for Environmental Studies (NIES), Japan. The origin of the material was tea leaves, which were ground, sieved through a 106-microm mesh, homogenized, and then subdivided into amber glass bottles. The results of homogeneity and stability tests indicated that the material was sufficiently homogeneous and stable for use as a reference material. The property values of the material were statistically determined based on chemical analyses by a network of laboratories using a wide range of methods. Sixteen laboratories participated in the characterization, and nine certified values and five reference values were obtained. These property values of the candidate CRM, which are expressed as mass fractions, were close to the median and/or mean values of the mass fractions of elements in various tea products. The candidate CRM is appropriate for use in analytical quality control and in the evaluation of methods used in the analysis of tea and materials of similar matrix.

  4. Nicotine, acetanilide and urea multi-level 2H-, 13C- and 15N-abundance reference materials for continuous-flow isotope ratio mass spectrometry.

    PubMed

    Schimmelmann, Arndt; Albertino, Andrea; Sauer, Peter E; Qi, Haiping; Molinie, Roland; Mesnard, François

    2009-11-01

    Accurate determinations of stable isotope ratios require a calibration using at least two reference materials with different isotopic compositions to anchor the isotopic scale and compensate for differences in machine slope. Ideally, the delta values of these reference materials should bracket the isotopic range of samples with unknown delta values. While the practice of analyzing two isotopically distinct reference materials is common for water (VSMOW-SLAP) and carbonates (NBS 19 and L-SVEC), the lack of widely available organic reference materials with distinct isotopic composition has hindered the practice when analyzing organic materials by elemental analysis/isotope ratio mass spectrometry (EA-IRMS). At present only L-glutamic acids USGS40 and USGS41 satisfy these requirements for delta13C and delta15N, with the limitation that L-glutamic acid is not suitable for analysis by gas chromatography (GC). We describe the development and quality testing of (i) four nicotine laboratory reference materials for on-line (i.e. continuous flow) hydrogen reductive gas chromatography-isotope ratio mass-spectrometry (GC-IRMS), (ii) five nicotines for oxidative C, N gas chromatography-combustion-isotope ratio mass-spectrometry (GC-C-IRMS, or GC-IRMS), and (iii) also three acetanilide and three urea reference materials for on-line oxidative EA-IRMS for C and N. Isotopic off-line calibration against international stable isotope measurement standards at Indiana University adhered to the 'principle of identical treatment'. The new reference materials cover the following isotopic ranges: delta2H(nicotine) -162 to -45 per thousand, delta13C(nicotine) -30.05 to +7.72 per thousand, delta15N(nicotine) -6.03 to +33.62 per thousand; delta15N(acetanilide) +1.18 to +40.57 per thousand; delta13C(urea) -34.13 to +11.71 per thousand, delta15N(urea) +0.26 to +40.61 per thousand (recommended delta values refer to calibration with NBS 19, L-SVEC, IAEA-N-1, and IAEA-N-2). Nicotines fill a gap as the first organic nitrogen stable isotope reference materials for GC-IRMS that are available with different delta15N values. Comparative delta13C and delta15N on-line EA-IRMS data from 14 volunteering laboratories document the usefulness and reliability of acetanilides and ureas as EA-IRMS reference materials. Copyright 2009 John Wiley & Sons, Ltd.

  5. Biological and environmental reference materials in CENAM.

    PubMed

    Arvizu-Torres, R; Perez-Castorena, A; Salas-Tellez, J A; Mitani-Nakanishi, Y

    2001-06-01

    Since 1994, when the NIST/NOAA Quality Assurance Program in Chemical Measurements was discussed in Queretaro, CENAM, the National Measurement Institute (NMI) of Mexico, has become involved in the development of reference materials. In the field of biological and environmental reference materials, in particular, the NORAMET collaboration program with NIST and NRC, and the North-American Environmental Cooperation signed among three free-trade treaty organizations, have greatly helped the development of the materials metrology program in the newly established CENAM. This paper describes some particularly significant efforts of CENAM in the development of biological and environmental reference materials, on the basis of inter-comparison studies organized with local and governmental environmental agencies of Mexico. In the field of water pollution CENAM has developed a practical proficiency testing (PT) scheme for field laboratories, as a part of registration by local government in the metropolitan area, according to the Mexican Ecological Regulation. The results from these eight PTs in the last 5 years have demonstrated that this scheme has helped ensure the reliability of analytical capability of more than 50 field laboratories in three states, Mexico, D.F., and the States of Mexico and Queretaro. Similar experience has been obtained for more than 70 service units of stack emission measurements in the three states in 1998 and 1999, as a result of the design of a PT scheme for reference gas mixtures. This PT scheme has been accomplished successfully by 30 analytical laboratories who provide monitoring services and perform research on toxic substances (Hg, methylmercury, PCB, etc.) in Mexico. To support these activities, reference samples have been produced through the NIST SRMs, and efforts have been made to increase CENAM's capability in the preparation of primary reference materials in spectrometric solutions and gas mixtures. Collaboration among NMIs has also successfully overcome the inability of CENAM to prepare biological tissue for mercury assessment and marine sediments for analysis of trace metals. The importance of international collaboration is stressed not only in the NORAMET region but also in the SIM, to provide help for each other and achieve mutual recognition among member countries of the region.

  6. Certification of elements in and use of standard reference material 3280 multivitamin/multielement tablets.

    PubMed

    Turk, Gregory C; Sharpless, Katherine E; Cleveland, Danielle; Jongsma, Candice; Mackey, Elizabeth A; Marlow, Anthony F; Oflaz, Rabia; Paul, Rick L; Sieber, John R; Thompson, Robert Q; Wood, Laura J; Yu, Lee L; Zeisler, Rolf; Wise, Stephen A; Yen, James H; Christopher, Steven J; Day, Russell D; Long, Stephen E; Greene, Ella; Harnly, James; Ho, I-Pin; Betz, Joseph M

    2013-01-01

    Standard Reference Material 3280 Multivitamin/ Multielement Tablets was issued by the National Institute of Standards and Technology in 2009, and has certified and reference mass fraction values for 13 vitamins, 26 elements, and two carotenoids. Elements were measured using two or more analytical methods at NIST with additional data contributed by collaborating laboratories. This reference material is expected to serve a dual purpose: to provide quality assurance in support of a database of dietary supplement products and to provide a means for analysts, dietary supplement manufacturers, and researchers to assess the appropriateness and validity of their analytical methods and the accuracy of their results.

  7. Development of a Genomic DNA Reference Material Panel for Myotonic Dystrophy Type 1 (DM1) Genetic Testing

    PubMed Central

    Kalman, Lisa; Tarleton, Jack; Hitch, Monica; Hegde, Madhuri; Hjelm, Nick; Berry-Kravis, Elizabeth; Zhou, Lili; Hilbert, James E.; Luebbe, Elizabeth A.; Moxley, Richard T.; Toji, Lorraine

    2014-01-01

    Myotonic dystrophy type 1 (DM1) is caused by expansion of a CTG triplet repeat in the 3′ untranslated region of the DMPK gene that encodes a serine-threonine kinase. Patients with larger repeats tend to have a more severe phenotype. Clinical laboratories require reference and quality control materials for DM1 diagnostic and carrier genetic testing. Well-characterized reference materials are not available. To address this need, the Centers for Disease Control and Prevention-based Genetic Testing Reference Material Coordination Program, in collaboration with members of the genetic testing community, the National Registry of Myotonic Dystrophy and Facioscapulohumeral Muscular Dystrophy Patients and Family Members, and the Coriell Cell Repositories, has established and characterized cell lines from patients with DM1 to create a reference material panel. The CTG repeats in genomic DNA samples from 10 DM1 cell lines were characterized in three clinical genetic testing laboratories using PCR and Southern blot analysis. DMPK alleles in the samples cover four of five DM1 clinical categories: normal (5 to 34 repeats), mild (50 to 100 repeats), classical (101 to 1000 repeats), and congenital (>1000 repeats). We did not identify or establish Coriell cell lines in the premutation range (35 to 49 repeats). These samples are publicly available for quality control, proficiency testing, test development, and research and should help improve the accuracy of DM1 testing. PMID:23680132

  8. The role of ion mobility spectrometry-mass spectrometry in the analysis of protein reference standards.

    PubMed

    Pritchard, Caroline; O'Connor, Gavin; Ashcroft, Alison E

    2013-08-06

    To achieve comparability of measurement results of protein amount of substance content between clinical laboratories, suitable reference materials are required. The impact on measurement comparability of potential differences in the tertiary and quaternary structure of protein reference standards is as yet not well understood. With the use of human growth hormone as a model protein, the potential of ion mobility spectrometry-mass spectrometry as a tool to assess differences in the structure of protein reference materials and their interactions with antibodies has been investigated here.

  9. Carboxyhaemoglobin: a possible reference material for haemoglobin assay.

    PubMed Central

    Rideout, J M; Louderback, A

    1982-01-01

    The inter- and intralaboratory quality control of haemoglobin estimation in remote laboratories requires a more rugged control haemolysate than is commercially available. The stabilities of oxyhaemoglobin and carboxyhaemoglobin forms of an ethanediol-containing haemolysate were studied over a three-year period. From the results obtained, carboxyhaemoglobin under nitrogen is proposed as a possible candidate reference material for haemoglobin assay. PMID:7068921

  10. A new basaltic glass microanalytical reference material for multiple techniques

    USGS Publications Warehouse

    Wilson, Steve; Koenig, Alan; Lowers, Heather

    2012-01-01

    The U.S. Geological Survey (USGS) has been producing reference materials since the 1950s. Over 50 materials have been developed to cover bulk rock, sediment, and soils for the geological community. These materials are used globally in geochemistry, environmental, and analytical laboratories that perform bulk chemistry and/or microanalysis for instrument calibration and quality assurance testing. To answer the growing demand for higher spatial resolution and sensitivity, there is a need to create a new generation of microanalytical reference materials suitable for a variety of techniques, such as scanning electron microscopy/X-ray spectrometry (SEM/EDS), electron probe microanalysis (EPMA), laser ablation inductively coupled mass spectrometry (LA-ICP-MS), and secondary ion mass spectrometry (SIMS). As such, the microanalytical reference material (MRM) needs to be stable under the beam, be homogeneous at scales of better than 10–25 micrometers for the major to ultra-trace element level, and contain all of the analytes (elements or isotopes) of interest. Previous development of basaltic glasses intended for LA-ICP-MS has resulted in a synthetic basaltic matrix series of glasses (USGS GS-series) and a natural basalt series of glasses (BCR-1G, BHVO-2G, and NKT-1G). These materials have been useful for the LA-ICP-MS community but were not originally intended for use by the electron or ion beam community. A material developed from start to finish with intended use in multiple microanalytical instruments would be useful for inter-laboratory and inter-instrument platform comparisons. This article summarizes the experiments undertaken to produce a basalt glass reference material suitable for distribution as a multiple-technique round robin material. The goal of the analytical work presented here is to demonstrate that the elemental homogeneity of the new glass is acceptable for its use as a reference material. Because the round robin exercise is still underway, only nominal compositional ranges for each element are given in the article.

  11. New Brunswick Laboratory. Progress report, October 1995--September 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Fiscal year (FY) 1996 was a very good year for New Brunswick Laboratory (NBL), whose major sponsor is the Office of Safeguards and Security (NN-51) in the US Department of Energy (DOE), Office of Nonproliferation and National Security, Office of Security Affairs. Several projects pertinent to the NBL mission were completed, and NBL`s interactions with partners and customers were encouraging. Among the partners with which NBL interacted in this report period were the International Atomic Energy Agency (IAEA), NN-51. Environmental Program Group of the DOE Chicago Operations Office, International Safeguards Project Office, Waste Isolation Pilot Plant (WIPP), Ukraine Working Group,more » Fissile Materials Assurance Working Group, National Institute of Standards and Technology (NIST), Nuclear Regulatory Commission (NRC), Institute for Reference Materials and Measurements (IRMM) in Belgium, Brazilian/Argentine Agency for Accounting and Control of Nuclear Materials (ABACC), Lockheed Idaho Technologies Company, and other DOE facilities and laboratories. NBL staff publications, participation in safeguards assistance and other nuclear programs, development of new reference materials, involvement in the updating and refinement of DOE documents, service in enhancing the science education of others, and other related activities enhanced NBL`s status among DOE laboratories and facilities. Noteworthy are the facts that NBL`s small inventory of nuclear materials is accurately accounted for, and, as in past years, its materials and human resources were used in peaceful nuclear activities worldwide.« less

  12. Development and Characterization of Reference Materials for Genetic Testing: Focus on Public Partnerships.

    PubMed

    Kalman, Lisa V; Datta, Vivekananda; Williams, Mickey; Zook, Justin M; Salit, Marc L; Han, Jin Yeong

    2016-11-01

    Characterized reference materials (RMs) are needed for clinical laboratory test development and validation, quality control procedures, and proficiency testing to assure their quality. In this article, we review the development and characterization of RMs for clinical molecular genetic tests. We describe various types of RMs and how to access and utilize them, especially focusing on the Genetic Testing Reference Materials Coordination Program (Get-RM) and the Genome in a Bottle (GIAB) Consortium. This review also reinforces the need for collaborative efforts in the clinical genetic testing community to develop additional RMs.

  13. Certified reference materials and reference methods for nuclear safeguards and security.

    PubMed

    Jakopič, R; Sturm, M; Kraiem, M; Richter, S; Aregbe, Y

    2013-11-01

    Confidence in comparability and reliability of measurement results in nuclear material and environmental sample analysis are established via certified reference materials (CRMs), reference measurements, and inter-laboratory comparisons (ILCs). Increased needs for quality control tools in proliferation resistance, environmental sample analysis, development of measurement capabilities over the years and progress in modern analytical techniques are the main reasons for the development of new reference materials and reference methods for nuclear safeguards and security. The Institute for Reference Materials and Measurements (IRMM) prepares and certifices large quantities of the so-called "large-sized dried" (LSD) spikes for accurate measurement of the uranium and plutonium content in dissolved nuclear fuel solutions by isotope dilution mass spectrometry (IDMS) and also develops particle reference materials applied for the detection of nuclear signatures in environmental samples. IRMM is currently replacing some of its exhausted stocks of CRMs with new ones whose specifications are up-to-date and tailored for the demands of modern analytical techniques. Some of the existing materials will be re-measured to improve the uncertainties associated with their certified values, and to enable laboratories to reduce their combined measurement uncertainty. Safeguards involve the quantitative verification by independent measurements so that no nuclear material is diverted from its intended peaceful use. Safeguards authorities pay particular attention to plutonium and the uranium isotope (235)U, indicating the so-called 'enrichment', in nuclear material and in environmental samples. In addition to the verification of the major ratios, n((235)U)/n((238)U) and n((240)Pu)/n((239)Pu), the minor ratios of the less abundant uranium and plutonium isotopes contain valuable information about the origin and the 'history' of material used for commercial or possibly clandestine purposes, and have therefore reached high level of attention for safeguards authorities. Furthermore, IRMM initiated and coordinated the development of a Modified Total Evaporation (MTE) technique for accurate abundance ratio measurements of the "minor" isotope-amount ratios of uranium and plutonium in nuclear material and, in combination with a multi-dynamic measurement technique and filament carburization, in environmental samples. Currently IRMM is engaged in a study on the development of plutonium reference materials for "age dating", i.e. determination of the time elapsed since the last separation of plutonium from its daughter nuclides. The decay of a radioactive parent isotope and the build-up of a corresponding amount of daughter nuclide serve as chronometer to calculate the age of a nuclear material. There are no such certified reference materials available yet. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Palm-Based Standard Reference Materials for Iodine Value and Slip Melting Point

    PubMed Central

    Tarmizi, Azmil Haizam Ahmad; Lin, Siew Wai; Kuntom, Ainie

    2008-01-01

    This work described study protocols on the production of Palm-Based Standard Reference Materials for iodine value and slip melting point. Thirty-three laboratories collaborated in the inter-laboratory proficiency tests for characterization of iodine value, while thirty-two laboratories for characterization of slip melting point. The iodine value and slip melting point of palm oil, palm olein and palm stearin were determined in accordance to MPOB Test Methods p3.2:2004 and p4.2:2004, respectively. The consensus values and their uncertainties were based on the acceptability of statistical agreement of results obtained from collaborating laboratories. The consensus values and uncertainties for iodine values were 52.63 ± 0.14 Wijs in palm oil, 56.77 ± 0.12 Wijs in palm olein and 33.76 ± 0.18 Wijs in palm stearin. For the slip melting points, the consensus values and uncertainties were 35.6 ± 0.3 °C in palm oil, 22.7 ± 0.4 °C in palm olein and 53.4 ± 0.2 °C in palm stearin. Repeatability and reproducibility relative standard deviations were found to be good and acceptable, with values much lower than that of 10%. Stability of Palm-Based Standard Reference Materials remained stable at temperatures of −20 °C, 0 °C, 6 °C and 24 °C upon storage for one year. PMID:19609396

  15. A Reference Method for Measuring Emissions of SVOCs in ...

    EPA Pesticide Factsheets

    Semivolatile organic compounds (SVOCs) are indoor air pollutants that may may have significant adverse effects on human health, and emission of SVOCs from building materials and consumer products is of growing concern. Few chamber studies have been conducted due to the challenges associated with SVOC analysis and the lack of validation procedures. Thus there is an urgent need for a reliable and accurate chamber test method to verify the performance of these measurements. A reference method employing a specially-designed chamber and experimental protocol has been developed and is undergoing extensive evaluation. A pilot interlaboratory study (ILS) has been conducted with five laboratories performing chamber tests under identical conditions. Results showed inter-laboratory variations at 25% for SVOC emission rates, with greater agreement observed between intra-laboratory measurements for most of the participating laboratories. The measured concentration profiles also compared reasonably well to the mechanistic model, demonstrating the feasibility of the proposed reference method to independently assess laboratory performance and validate SVOC emission tests. There is an urgent need for improved understanding of the measurement uncertainties associated with SVOC emissions testing. The creation of specially-designed chambers and well-characterized materials serves as a critical prerequisite for improving the procedure used to measure SVOCs emitted from indoor

  16. Challenges in the size analysis of a silica nanoparticle mixture as candidate certified reference material

    NASA Astrophysics Data System (ADS)

    Kestens, Vikram; Roebben, Gert; Herrmann, Jan; Jämting, Åsa; Coleman, Victoria; Minelli, Caterina; Clifford, Charles; De Temmerman, Pieter-Jan; Mast, Jan; Junjie, Liu; Babick, Frank; Cölfen, Helmut; Emons, Hendrik

    2016-06-01

    A new certified reference material for quality control of nanoparticle size analysis methods has been developed and produced by the Institute for Reference Materials and Measurements of the European Commission's Joint Research Centre. The material, ERM-FD102, consists of an aqueous suspension of a mixture of silica nanoparticle populations of distinct particle size and origin. The characterisation relied on an interlaboratory comparison study in which 30 laboratories of demonstrated competence participated with a variety of techniques for particle size analysis. After scrutinising the received datasets, certified and indicative values for different method-defined equivalent diameters that are specific for dynamic light scattering (DLS), centrifugal liquid sedimentation (CLS), scanning and transmission electron microscopy (SEM and TEM), atomic force microscopy (AFM), particle tracking analysis (PTA) and asymmetrical-flow field-flow fractionation (AF4) were assigned. The value assignment was a particular challenge because metrological concepts were not always interpreted uniformly across all participating laboratories. This paper presents the main elements and results of the ERM-FD102 characterisation study and discusses in particular the key issues of measurand definition and the estimation of measurement uncertainty.

  17. Multicenter Evaluation of a Commercial Cytomegalovirus Quantitative Standard: Effects of Commutability on Interlaboratory Concordance

    PubMed Central

    Shahbazian, M. D.; Valsamakis, A.; Boonyaratanakornkit, J.; Cook, L.; Pang, X. L.; Preiksaitis, J. K.; Schönbrunner, E. R.; Caliendo, A. M.

    2013-01-01

    Commutability of quantitative reference materials has proven important for reliable and accurate results in clinical chemistry. As international reference standards and commercially produced calibration material have become available to address the variability of viral load assays, the degree to which such materials are commutable and the effect of commutability on assay concordance have been questioned. To investigate this, 60 archived clinical plasma samples, which previously tested positive for cytomegalovirus (CMV), were retested by five different laboratories, each using a different quantitative CMV PCR assay. Results from each laboratory were calibrated both with lab-specific quantitative CMV standards (“lab standards”) and with common, commercially available standards (“CMV panel”). Pairwise analyses among laboratories were performed using mean results from each clinical sample, calibrated first with lab standards and then with the CMV panel. Commutability of the CMV panel was determined based on difference plots for each laboratory pair showing plotted values of standards that were within the 95% prediction intervals for the clinical specimens. Commutability was demonstrated for 6 of 10 laboratory pairs using the CMV panel. In half of these pairs, use of the CMV panel improved quantitative agreement compared to use of lab standards. Two of four laboratory pairs for which the CMV panel was noncommutable showed reduced quantitative agreement when that panel was used as a common calibrator. Commutability of calibration material varies across different quantitative PCR methods. Use of a common, commutable quantitative standard can improve agreement across different assays; use of a noncommutable calibrator can reduce agreement among laboratories. PMID:24025907

  18. Development of a genomic DNA reference material panel for myotonic dystrophy type 1 (DM1) genetic testing.

    PubMed

    Kalman, Lisa; Tarleton, Jack; Hitch, Monica; Hegde, Madhuri; Hjelm, Nick; Berry-Kravis, Elizabeth; Zhou, Lili; Hilbert, James E; Luebbe, Elizabeth A; Moxley, Richard T; Toji, Lorraine

    2013-07-01

    Myotonic dystrophy type 1 (DM1) is caused by expansion of a CTG triplet repeat in the 3' untranslated region of the DMPK gene that encodes a serine-threonine kinase. Patients with larger repeats tend to have a more severe phenotype. Clinical laboratories require reference and quality control materials for DM1 diagnostic and carrier genetic testing. Well-characterized reference materials are not available. To address this need, the Centers for Disease Control and Prevention-based Genetic Testing Reference Material Coordination Program, in collaboration with members of the genetic testing community, the National Registry of Myotonic Dystrophy and Facioscapulohumeral Muscular Dystrophy Patients and Family Members, and the Coriell Cell Repositories, has established and characterized cell lines from patients with DM1 to create a reference material panel. The CTG repeats in genomic DNA samples from 10 DM1 cell lines were characterized in three clinical genetic testing laboratories using PCR and Southern blot analysis. DMPK alleles in the samples cover four of five DM1 clinical categories: normal (5 to 34 repeats), mild (50 to 100 repeats), classical (101 to 1000 repeats), and congenital (>1000 repeats). We did not identify or establish Coriell cell lines in the premutation range (35 to 49 repeats). These samples are publicly available for quality control, proficiency testing, test development, and research and should help improve the accuracy of DM1 testing. Copyright © 2013 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  19. Analytical Bias Exceeding Desirable Quality Goal in 4 out of 5 Common Immunoassays: Results of a Native Single Serum Sample External Quality Assessment Program for Cobalamin, Folate, Ferritin, Thyroid-Stimulating Hormone, and Free T4 Analyses.

    PubMed

    Kristensen, Gunn B B; Rustad, Pål; Berg, Jens P; Aakre, Kristin M

    2016-09-01

    We undertook this study to evaluate method differences for 5 components analyzed by immunoassays, to explore whether the use of method-dependent reference intervals may compensate for method differences, and to investigate commutability of external quality assessment (EQA) materials. Twenty fresh native single serum samples, a fresh native serum pool, Nordic Federation of Clinical Chemistry Reference Serum X (serum X) (serum pool), and 2 EQA materials were sent to 38 laboratories for measurement of cobalamin, folate, ferritin, free T4, and thyroid-stimulating hormone (TSH) by 5 different measurement procedures [Roche Cobas (n = 15), Roche Modular (n = 4), Abbott Architect (n = 8), Beckman Coulter Unicel (n = 2), and Siemens ADVIA Centaur (n = 9)]. The target value for each component was calculated based on the mean of method means or measured by a reference measurement procedure (free T4). Quality specifications were based on biological variation. Local reference intervals were reported from all laboratories. Method differences that exceeded acceptable bias were found for all components except folate. Free T4 differences from the uncommonly used reference measurement procedure were large. Reference intervals differed between measurement procedures but also within 1 measurement procedure. The serum X material was commutable for all components and measurement procedures, whereas the EQA materials were noncommutable in 13 of 50 occasions (5 components, 5 methods, 2 EQA materials). The bias between the measurement procedures was unacceptably large in 4/5 tested components. Traceability to reference materials as claimed by the manufacturers did not lead to acceptable harmonization. Adjustment of reference intervals in accordance with method differences and use of commutable EQA samples are not implemented commonly. © 2016 American Association for Clinical Chemistry.

  20. Interlaboratory comparison program for nondestructive assay of prototype uranium reference materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trahey, N.M.; Smith, M.M.; Voeks, A.M.

    The US Department of Energy (DOE), New Brunswick Laboratory (NBS), designed and administered an interlaboratory comparison program based on the measurement of NBL-produced prototype uranium nondestructive assay (NDA) reference materials for scrap and waste. The objectives of the program were to evaluate the reliability of NDA techniques as applied to nuclear safeguards materials control and accountability needs and to investigate the feasibility of providing practical NDA scrap and waste reference materials for use throughout the nuclear safeguards community. Fourteen facilities representing seven DOE contractors, four US Nuclear Regulatory Commission (NRC) licensees, one EURATOM Laboratory, and NBL, participated in this program.more » Three stable, well-characterized uranium reference materials were developed and certified for this program. Synthetic calcined ash, cellulose fiber, and ion-exchange resin simulate selected uranium scrap and waste forms which are often encountered in fabrication and recovery operations. The synthetic calcined ash represents an intermediate density inorganic matrix while the cellulose fiber and ion-exchange resin are representative of low-density organic matrices. The materials, containing from 0 to 13% uranium enriched at 93% /sup 235/U, were sealed in specially selected containers. Nineteen prototype reference samples, plus three empty containers, one to accompany each set, was circulated to the participants between August 1979 and May 1984. Triplicate measurements for /sup 235/U on each of the 19 filled containers were required. In addition, participants could opt to perform modular configuration measurements using containers from Sets IIA and IIB to simulate non-homogeneously dispersed uranium in waste containers. All data were reported to NBL for evaluation.« less

  1. Interlaboratory comparison for the measurement of particle size and zeta potential of silica nanoparticles in an aqueous suspension

    NASA Astrophysics Data System (ADS)

    Lamberty, Andrée; Franks, Katrin; Braun, Adelina; Kestens, Vikram; Roebben, Gert; Linsinger, Thomas P. J.

    2011-12-01

    The Institute for Reference Materials and Measurements has organised an interlaboratory comparison (ILC) to allow the participating laboratories to demonstrate their proficiency in particle size and zeta potential measurements on monomodal aqueous suspensions of silica nanoparticles in the 10-100 nm size range. The main goal of this ILC was to identify competent collaborators for the production of certified nanoparticle reference materials. 38 laboratories from four different continents participated in the ILC with different methods for particle sizing and determination of zeta potential. Most of the laboratories submitted particle size results obtained with centrifugal liquid sedimentation (CLS), dynamic light scattering (DLS) or electron microscopy (EM), or zeta potential values obtained via electrophoretic light scattering (ELS). The results of the laboratories were evaluated using method-specific z scores, calculated on the basis of consensus values from the ILC. For CLS (13 results) and EM (13 results), all reported values were within the ±2 | z| interval. For DLS, 25 of the 27 results reported were within the ±2 | z| interval, the two other results were within the ±3 | z| interval. The standard deviations of the corresponding laboratory mean values varied between 3.7 and 6.5%, which demonstrates satisfactory interlaboratory comparability of CLS, DLS and EM particle size values. From the received test reports, a large discrepancy was observed in terms of the laboratory's quality assurance systems, which are equally important for the selection of collaborators in reference material certification projects. Only a minority of the participating laboratories is aware of all the items that are mandatory in test reports compliant to ISO/IEC 17025 (ISO General requirements for the competence of testing and calibration laboratories. International Organisation for Standardization, Geneva, 2005b). The absence of measurement uncertainty values in the reports, for example, hindered the calculation of zeta scores.

  2. Certification of a reference material for determination of total cyanide in soil to support implementation of the International Standard ISO 11262:2011.

    PubMed

    Scharf, Holger; Bremser, Wolfram

    2015-04-01

    Cyanides are among the most important inorganic pollutants to be tested and monitored in environmental compartments. They can be distinguished and determined as free cyanide, weak acid dissociable cyanide or as total cyanide. However, in any case obtained, measurement results are operationally defined referring to the applied analytical method. In 2011, the International Standard ISO 11262 has been published which specifies a normative analytical method for the determination of total cyanide in soil. The objective of the project described in this paper was to provide the first soil reference material (CRM) certified for its mass fraction of total cyanide on the basis of this standard. A total of 12 German laboratories with proven experience in the determination of cyanides in environmental samples participated in the certification study. Measurement results were evaluated in full compliance with the requirements of ISO Guide 35. Taking into account the results of the inter-laboratory comparison as well as the outcome of the homogeneity and stability studies, a certified mass fraction of total cyanide of 21.1 mg/kg and an expanded uncertainty (k = 2) of 1.3 mg/kg were assigned to the material. The reference material has been issued as CRM BAM-U114.

  3. Critical outlook and trends for environmental reference materials at the Measurements & Testing Generic Activity (European Commission).

    PubMed

    Quevauviller, P; Bennink, D; Bøwadt, S

    2001-05-01

    It is now well recognised that the quality control (QC) of all types of analyses, including environmental analyses depends on the appropriate use of reference materials. One of the ways to check the accuracy of methods is based on the use of Certified Reference Materials (CRMs), whereas other types of (not certified) Reference Materials (RMs) are used for routine quality control (establishment of control charts) and interlaboratory testing (e.g. proficiency testing). The perception of these materials, in particular with respect to their production and use, differs widely according to various perspectives (e.g. RM producers, routine laboratories, researchers). This review discusses some critical aspects of RM use and production for the QC of environmental analyses and describes the new approach followed by the Measurements & Testing Generic Activity (European Commission) to tackle new research and production needs.

  4. The role of standards in the development and implementation of clinical laboratory tests: a domestic and global perspective.

    PubMed

    Michaud, Ginette Y

    2005-01-01

    In the field of clinical laboratory medicine, standardization is aimed at increasing the trueness and reliability of measured values. Standardization relies on the use of written standards, reference measurement procedures and reference materials. These are important tools for the design and validation of new tests, and for establishing the metrological traceability of diagnostic assays. Their use supports the translation of research technologies into new diagnostic assays and leads to more rapid advances in science and medicine, as well as improvements in the quality of patient care. The various standardization tools are described, as are the procedures by which written standards, reference procedures and reference materials are developed. Recent efforts to develop standards for use in the field of molecular diagnostics are discussed. The recognition of standardization tools by the FDA and other regulatory authorities is noted as evidence of their important role in ensuring the safety and performance of in vitro diagnostic devices.

  5. [The requirements of standard and conditions of interchangeability of medical articles].

    PubMed

    Men'shikov, V V; Lukicheva, T I

    2013-11-01

    The article deals with possibility to apply specific approaches under evaluation of interchangeability of medical articles for laboratory analysis. The development of standardized analytical technologies of laboratory medicine and formulation of requirements of standards addressed to manufacturers of medical articles the clinically validated requirements are to be followed. These requirements include sensitivity and specificity of techniques, accuracy and precision of research results, stability of reagents' quality in particular conditions of their transportation and storage. The validity of requirements formulated in standards and addressed to manufacturers of medical articles can be proved using reference system, which includes master forms and standard samples, reference techniques and reference laboratories. This approach is supported by data of evaluation of testing systems for measurement of level of thyrotrophic hormone, thyroid hormones and glycated hemoglobin HB A1c. The versions of testing systems can be considered as interchangeable only in case of results corresponding to the results of reference technique and comparable with them. In case of absence of functioning reference system the possibilities of the Joined committee of traceability in laboratory medicine make it possible for manufacturers of reagent sets to apply the certified reference materials under development of manufacturing of sets for large listing of analytes.

  6. The importance of reference materials in doping-control analysis.

    PubMed

    Mackay, Lindsey G; Kazlauskas, Rymantas

    2011-08-01

    Currently a large range of pure substance reference materials are available for calibration of doping-control methods. These materials enable traceability to the International System of Units (SI) for the results generated by World Anti-Doping Agency (WADA)-accredited laboratories. Only a small number of prohibited substances have threshold limits for which quantification is highly important. For these analytes only the highest quality reference materials that are available should be used. Many prohibited substances have no threshold limits and reference materials provide essential identity confirmation. For these reference materials the correct identity is critical and the methods used to assess identity in these cases should be critically evaluated. There is still a lack of certified matrix reference materials to support many aspects of doping analysis. However, in key areas a range of urine matrix materials have been produced for substances with threshold limits, for example 19-norandrosterone and testosterone/epitestosterone (T/E) ratio. These matrix-certified reference materials (CRMs) are an excellent independent means of checking method recovery and bias and will typically be used in method validation and then regularly as quality-control checks. They can be particularly important in the analysis of samples close to threshold limits, in which measurement accuracy becomes critical. Some reference materials for isotope ratio mass spectrometry (IRMS) analysis are available and a matrix material certified for steroid delta values is currently under production. In other new areas, for example the Athlete Biological Passport, peptide hormone testing, designer steroids, and gene doping, reference material needs still need to be thoroughly assessed and prioritised.

  7. Optimizing soft X-ray NEXAFS spectroscopy in the laboratory

    NASA Astrophysics Data System (ADS)

    Mantouvalou, I.; Jonas, A.; Witte, K.; Jung, R.; Stiel, H.; Kanngießer, B.

    2017-05-01

    Near edge X-ray absorption fine structure (NEXAFS) spectroscopy in the soft X-ray range is feasible in the laboratory using laser-produced plasma sources. We present a study using seven different target materials for optimized data analysis. The emission spectra of the materials with atomic numbers ranging from Z = 6 to Z = 79 show distinct differences, rendering the adapted selection of a suitable target material for specialized experiments feasible. For NEXAFS spectroscopy a 112.5 nm thick polyimide film is investigated as a reference exemplifying the superiority of quasi-continuum like emission spectra.

  8. Surviving the space environment - An overview of advanced materials and structures development at the CWRU CCDS

    NASA Technical Reports Server (NTRS)

    Wallace, John F.; Zdankiewicz, Edward M.; Schmidt, Robert N.

    1991-01-01

    The development of advanced materials and structures for long-term use in space is described with specific reference given to applications to the Space Station Freedom and the lunar base. A flight-testing program is described which incorporates experiments regarding the passive effects of space travel such as material degradation with active materials experiments such as the Materials Exposure Flight Experiment. Also described is a research and development program for materials such as organic coatings and polymeric composites, and a simulation laboratory is described which permits the analysis of materials in the laboratory. The methods of investigation indicate that the NASA Center for the Commercial Development of Space facilitates the understanding of material degradation in space.

  9. 33 CFR 181.4 - Incorporation by reference.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... available to the public. All approved material is available for inspection at the Lifesaving and Fire Safety Standards Division (CG-5214), 2100 2nd St., SW., Stop 7126, Washington, DC 20593-7126, and at the National...: Underwriters Laboratories, Inc. (UL) 12 Laboratory Drive, Research Triangle Park, NC 27709-3995 UL 1123, Marine...

  10. 33 CFR 181.4 - Incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... available to the public. All approved material is available for inspection at the Lifesaving and Fire Safety Standards Division (CG-5214), 2100 2nd St., SW., Stop 7126, Washington, DC 20593-7126, and at the National...: Underwriters Laboratories, Inc. (UL) 12 Laboratory Drive, Research Triangle Park, NC 27709-3995 UL 1123, Marine...

  11. 46 CFR 160.076-11 - Incorporation by reference.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... the public. All approved material is available for inspection at the National Archives and Records Administration (NARA) and at the U.S. Coast Guard, Lifesaving and Fire Safety Division (CG-ENG-4), 2100 2nd St...) Underwriters Laboratories (UL) Underwriters Laboratories, Inc., 333 Pfingsten Road, Northbrook, IL 60062-2096...

  12. 33 CFR 181.4 - Incorporation by reference.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... available to the public. All approved material is available for inspection at the Lifesaving and Fire Safety Standards Division (CG-5214), 2100 2nd St., SW., Stop 7126, Washington, DC 20593-7126, and at the National...: Underwriters Laboratories, Inc. (UL) 12 Laboratory Drive, Research Triangle Park, NC 27709-3995 UL 1123, Marine...

  13. 33 CFR 181.4 - Incorporation by reference.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... available to the public. All approved material is available for inspection at the Lifesaving and Fire Safety Standards Division (CG-5214), 2100 2nd St., SW., Stop 7126, Washington, DC 20593-7126, and at the National...: Underwriters Laboratories, Inc. (UL) 12 Laboratory Drive, Research Triangle Park, NC 27709-3995 UL 1123, Marine...

  14. 33 CFR 181.4 - Incorporation by reference.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... available to the public. All approved material is available for inspection at the Lifesaving and Fire Safety Standards Division (CG-5214), 2100 2nd St., SW., Stop 7126, Washington, DC 20593-7126, and at the National...: Underwriters Laboratories, Inc. (UL) 12 Laboratory Drive, Research Triangle Park, NC 27709-3995 UL 1123, Marine...

  15. 46 CFR 28.40 - Incorporation by reference.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... available to the public. All approved material is on file at the U.S. Coast Guard, Office of Design and... (Lightweight Survey and Inclining Experiment) to Determine the Light Ship Displacement and Centers of Gravity... Applications 28.405 Underwriters Laboratories, Inc. (UL), 12 Laboratory Drive, Research Triangle Park, NC 27709...

  16. 46 CFR 28.40 - Incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... available to the public. All approved material is on file at the U.S. Coast Guard, Office of Design and... (Lightweight Survey and Inclining Experiment) to Determine the Light Ship Displacement and Centers of Gravity... Applications 28.405 Underwriters Laboratories, Inc. (UL), 12 Laboratory Drive, Research Triangle Park, NC 27709...

  17. 46 CFR 28.40 - Incorporation by reference.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... available to the public. All approved material is on file at the U.S. Coast Guard, Office of Design and... (Lightweight Survey and Inclining Experiment) to Determine the Light Ship Displacement and Centers of Gravity... Applications 28.405 Underwriters Laboratories, Inc. (UL), 12 Laboratory Drive, Research Triangle Park, NC 27709...

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eppich, G.; Kips, R.; Lindvall, R.

    The CUP-2 uranium ore concentrate (UOC) standard reference material, a powder, was produced at the Blind River uranium refinery of Eldorado Resources Ltd. in Canada in 1986. This material was produced as part of a joint effort by the Canadian Certified Reference Materials Project and the Canadian Uranium Producers Metallurgical Committee to develop a certified reference material for uranium concentration and the concentration of several impurity constituents. This standard was developed to satisfy the requirements of the UOC mining and milling industry, and was characterized with this purpose in mind. To produce CUP-2, approximately 25 kg of UOC derived frommore » the Blind River uranium refinery was blended, homogenized, and assessed for homogeneity by X-ray fluorescence (XRF) analysis. The homogenized material was then packaged into bottles, containing 50 g of material each, and distributed for analysis to laboratories in 1986. The CUP-2 UOC standard was characterized by an interlaboratory analysis program involving eight member laboratories, six commercial laboratories, and three additional volunteer laboratories. Each laboratory provided five replicate results on up to 17 analytes, including total uranium concentration, and moisture content. The selection of analytical technique was left to each participating laboratory. Uranium was reported on an “as-received” basis; all other analytes (besides moisture content) were reported on a “dry-weight” basis. A bottle of 25g of CUP-2 UOC standard as described above was purchased by LLNL and characterized by the LLNL Nuclear Forensics Group. Non-destructive and destructive analytical techniques were applied to the UOC sample. Information obtained from short-term techniques such as photography, gamma spectrometry, and scanning electron microscopy were used to guide the performance of longer-term techniques such as ICP-MS. Some techniques, such as XRF and ICP-MS, provided complementary types of data. The results indicate that the CUP-2 standard has a natural isotopic ratio, and does not appear to have been isotopically enriched or depleted in any way, and was not contaminated by a source of uranium with a non-natural isotopic composition. Furthermore, the lack of 233U and 236U above the instrumental detection limit indicates that this sample was not exposed to a neutron flux, which would have generated one or both of these isotopes in measurable concentrations.« less

  19. Preparation and Use of Polish Mushroom Proficiency Testing Materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Polkowska-Motrenko, Halina

    2008-08-14

    Mushroom reference materials have been prepared and characterized for the use in proficiency tests according to a procedure established within the frame of an IAEA Interregional Technical Cooperation Project. The materials were used for conducting the proficiency tests in Poland in 2005-2007. The results obtained by participating laboratories are presented and discussed.

  20. Results of a Saxitoxin Proficiency Test Including Characterization of Reference Material and Stability Studies

    PubMed Central

    Harju, Kirsi; Rapinoja, Marja-Leena; Avondet, Marc-André; Arnold, Werner; Schär, Martin; Luginbühl, Werner; Kremp, Anke; Suikkanen, Sanna; Kankaanpää, Harri; Burrell, Stephen; Söderström, Martin; Vanninen, Paula

    2015-01-01

    A saxitoxin (STX) proficiency test (PT) was organized as part of the Establishment of Quality Assurance for the Detection of Biological Toxins of Potential Bioterrorism Risk (EQuATox) project. The aim of this PT was to provide an evaluation of existing methods and the European laboratories’ capabilities for the analysis of STX and some of its analogues in real samples. Homogenized mussel material and algal cell materials containing paralytic shellfish poisoning (PSP) toxins were produced as reference sample matrices. The reference material was characterized using various analytical methods. Acidified algal extract samples at two concentration levels were prepared from a bulk culture of PSP toxins producing dinoflagellate Alexandrium ostenfeldii. The homogeneity and stability of the prepared PT samples were studied and found to be fit-for-purpose. Thereafter, eight STX PT samples were sent to ten participating laboratories from eight countries. The PT offered the participating laboratories the possibility to assess their performance regarding the qualitative and quantitative detection of PSP toxins. Various techniques such as official Association of Official Analytical Chemists (AOAC) methods, immunoassays, and liquid chromatography-mass spectrometry were used for sample analyses. PMID:26602927

  1. Value assignment of nutrient concentrations in five standard reference materials and six reference materials.

    PubMed

    Sharpless, K E; Gill, L M

    2000-01-01

    A number of food-matrix reference materials (RMs) are available from the National Institute of Standards and Technology (NIST) and from Agriculture Canada through NIST. Most of these materials were originally value-assigned for their elemental composition (major, minor, and trace elements), but no additional nutritional information was provided. Two of the materials were certified for selected organic constituents. Ten of these materials (Standard Reference Material [SRM] 1,563 Cholesterol and Fat-Soluble Vitamins in Coconut Oil [Natural and Fortified], SRM 1,566b Oyster Tissue, SRM 1,570a Spinach Leaves, SRM 1,974a Organics in Mussel Tissue (Mytilus edulis), RM 8,415 Whole Egg Powder, RM 8,418 Wheat Gluten, RM 8,432 Corn Starch, RM 8,433 Corn Bran, RM 8,435 Whole Milk Powder, and RM 8,436 Durum Wheat Flour) were recently distributed by NIST to 4 laboratories with expertise in food analysis for the measurement of proximates (solids, fat, protein, etc.), calories, and total dietary fiber, as appropriate. SRM 1846 Infant Formula was distributed as a quality control sample for the proximates and for analysis for individual fatty acids. Two of the materials (Whole Egg Powder and Whole Milk Powder) were distributed in an earlier interlaboratory comparison exercise in which they were analyzed for several vitamins. Value assignment of analyte concentrations in these 11 SRMs and RMs, based on analyses by the collaborating laboratories, is described in this paper. These materials are intended primarily for validation of analytical methods for the measurement of nutrients in foods of similar composition (based on AOAC INTERNATIONAL's fat-protein-carbohydrate triangle). They may also be used as "primary control materials" in the value assignment of in-house control materials of similar composition. The addition of proximate information for 10 existing reference materials means that RMs are now available from NIST with assigned values for proximates in 6 of the 9 sectors of the AOAC triangle. Five of these materials have values assigned for total dietary fiber-the first such information provided for materials available from NIST.

  2. New reference materials for nitrogen-isotope-ratio measurements

    USGS Publications Warehouse

    Böhlke, John Karl; Gwinn, C. J.; Coplen, T. B.

    1993-01-01

    Three new reference materials were manufactured for calibration of relative stable nitrogen-isotope-ratio measurements: USGS25 (ammonium sulfate) d15N' = -30 per mil; USGS26 (ammonium sulfate) d15N' = +54 per mil; USGS32 (potassium nitrate) d15N' = +180 per mil, where d15N', relative to atmospheric nitrogen, is an approximate value subject to change following interlaboratory comparisons. These materials are isotopically homogeneous in aliquots at least as small as 10 µmol N2 (or about 1-2 mg of salt). The new reference materials greatly extend the range of d15N values of internationally distributed standards, and they allow normalization of d15N measurements over almost the full range of known natural isotope variation on Earth. The methods used to produce these materials may be adapted to produce homogeneous local laboratory standards for routine use.

  3. Two New Reference Materials Based on Tobacco Leaves: Certification for over a Dozen of Toxic and Essential Elements

    PubMed Central

    Samczyński, Zbigniew; Dybczyński, Rajmund S.; Polkowska-Motrenko, Halina; Chajduk, Ewelina; Pyszynska, Marta; Danko, Bożena; Czerska, Elżbieta; Kulisa, Krzysztof; Doner, Katarzyna; Kalbarczyk, Paweł

    2012-01-01

    The preparation, certification, and characterization of two new biological certified reference materials for inorganic trace analysis have been presented. They are based on two different varieties of tobacco leaves, namely, Oriental Basma Tobacco Leaves (INCT-OBTL-5), grown in Greece, and Polish Virginia Tobacco Leaves (INCT-PVTL-6), grown in Poland. Certification of the materials was based on the statistical evaluation of results obtained in a worldwide interlaboratory comparison, in which 87 laboratories from 18 countries participated, providing 2568 laboratory averages on nearly 80 elements. It was possible to establish the certified values of concentration for many elements in the new materials, that is, 37 in INCT-OBTL-5 and 36 in INCT-PVTL-6, including several toxic ones like As, Cd, Hg, Pb, and so forth. The share and the role of instrumental analytical techniques used in the process of certification of the new CRMs are discussed. PMID:22536124

  4. Determination of polychlorinated dibenzo-p-dioxin and dibenzofuran congeners in air particulate and marine sediment standard reference materials (SRMs).

    PubMed

    Chiu, C H; Turle, R; Poole, G; Thibert, B; Brubaker, W W; Schantz, M M; Wise, S A

    2001-02-01

    Due to the limited number of environmental matrix certified reference materials (CRMs) with assigned values for natural levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), an interlaboratory study was undertaken by the National Institute of Standards and Technology (NIST) and Environment Canada to establish reference concentration values for selected PCDD/Fs in two well-characterized NIST Standard Reference Materials (SRMs): SRM 1649a (Urban Dust) and SRM 1944 (New York/New Jersey Waterway Sediment). Results from 14 laboratories were used to provide reference values for the seventeen 2, 3, 7, 8-substituted PCDD/F congeners, the totals for individual tetra- through hepta-substituted PCDD/F homologues, and the total amount of tetra- through hepta-substituted PCDD/Fs. The mass fractions for the individual 2, 3, 7, 8-substituted congeners range from approximately 0.01 microg/kg to 7 microg/kg dry mass.

  5. Harmonizing lipidomics: NIST interlaboratory comparison exercise for lipidomics using SRM 1950-Metabolites in Frozen Human Plasma.

    PubMed

    Bowden, John A; Heckert, Alan; Ulmer, Candice Z; Jones, Christina M; Koelmel, Jeremy P; Abdullah, Laila; Ahonen, Linda; Alnouti, Yazen; Armando, Aaron M; Asara, John M; Bamba, Takeshi; Barr, John R; Bergquist, Jonas; Borchers, Christoph H; Brandsma, Joost; Breitkopf, Susanne B; Cajka, Tomas; Cazenave-Gassiot, Amaury; Checa, Antonio; Cinel, Michelle A; Colas, Romain A; Cremers, Serge; Dennis, Edward A; Evans, James E; Fauland, Alexander; Fiehn, Oliver; Gardner, Michael S; Garrett, Timothy J; Gotlinger, Katherine H; Han, Jun; Huang, Yingying; Neo, Aveline Huipeng; Hyötyläinen, Tuulia; Izumi, Yoshihiro; Jiang, Hongfeng; Jiang, Houli; Jiang, Jiang; Kachman, Maureen; Kiyonami, Reiko; Klavins, Kristaps; Klose, Christian; Köfeler, Harald C; Kolmert, Johan; Koal, Therese; Koster, Grielof; Kuklenyik, Zsuzsanna; Kurland, Irwin J; Leadley, Michael; Lin, Karen; Maddipati, Krishna Rao; McDougall, Danielle; Meikle, Peter J; Mellett, Natalie A; Monnin, Cian; Moseley, M Arthur; Nandakumar, Renu; Oresic, Matej; Patterson, Rainey; Peake, David; Pierce, Jason S; Post, Martin; Postle, Anthony D; Pugh, Rebecca; Qiu, Yunping; Quehenberger, Oswald; Ramrup, Parsram; Rees, Jon; Rembiesa, Barbara; Reynaud, Denis; Roth, Mary R; Sales, Susanne; Schuhmann, Kai; Schwartzman, Michal Laniado; Serhan, Charles N; Shevchenko, Andrej; Somerville, Stephen E; St John-Williams, Lisa; Surma, Michal A; Takeda, Hiroaki; Thakare, Rhishikesh; Thompson, J Will; Torta, Federico; Triebl, Alexander; Trötzmüller, Martin; Ubhayasekera, S J Kumari; Vuckovic, Dajana; Weir, Jacquelyn M; Welti, Ruth; Wenk, Markus R; Wheelock, Craig E; Yao, Libin; Yuan, Min; Zhao, Xueqing Heather; Zhou, Senlin

    2017-12-01

    As the lipidomics field continues to advance, self-evaluation within the community is critical. Here, we performed an interlaboratory comparison exercise for lipidomics using Standard Reference Material (SRM) 1950-Metabolites in Frozen Human Plasma, a commercially available reference material. The interlaboratory study comprised 31 diverse laboratories, with each laboratory using a different lipidomics workflow. A total of 1,527 unique lipids were measured across all laboratories and consensus location estimates and associated uncertainties were determined for 339 of these lipids measured at the sum composition level by five or more participating laboratories. These evaluated lipids detected in SRM 1950 serve as community-wide benchmarks for intra- and interlaboratory quality control and method validation. These analyses were performed using nonstandardized laboratory-independent workflows. The consensus locations were also compared with a previous examination of SRM 1950 by the LIPID MAPS consortium. While the central theme of the interlaboratory study was to provide values to help harmonize lipids, lipid mediators, and precursor measurements across the community, it was also initiated to stimulate a discussion regarding areas in need of improvement. Copyright © 2017 by the American Society for Biochemistry and Molecular Biology, Inc.

  6. Update for combustion properties of wood components

    Treesearch

    Mark Dietenberger

    2002-01-01

    The combustion properties of various biomass and wood materials from various references and from our laboratory were reanalysed. The net heat of combustion for cellulosic materials was found to be 13.23 kJ/g times the ratio of stoichiometric oxygen mass to fuel mass, r[subscript]o, regardless of the material composition. Bomb calorimeter data for original, charred and...

  7. Development of candidate reference materials for the measurement of lead in bone

    PubMed Central

    Hetter, Katherine M.; Bellis, David J.; Geraghty, Ciaran; Todd, Andrew C.; Parsons, Patrick J.

    2010-01-01

    The production of modest quantities of candidate bone lead (Pb) reference materials is described, and an optimized production procedure is presented. The reference materials were developed to enable an assessment of the interlaboratory agreement of laboratories measuring Pb in bone; method validation; and for calibration of solid sampling techniques such as laser ablation ICP-MS. Long bones obtained from Pb-dosed and undosed animals were selected to produce four different pools of a candidate powdered bone reference material. The Pb concentrations of these pools reflect both environmental and occupational exposure levels in humans. The animal bones were harvested post mortem, cleaned, defatted, and broken into pieces using the brittle fracture technique at liquid nitrogen temperature. The bone pieces were then ground in a knife mill to produce fragments of 2-mm size. These were further ground in an ultra-centrifugal mill, resulting in finely powdered bone material that was homogenized and then sampled-scooped into vials. Testing for contamination and homogeneity was performed via instrumental methods of analysis. PMID:18421443

  8. Sandia and General Motors: Advancing Clean Combustion Engines with

    Science.gov Websites

    Quantitative Risk Assessment Technical Reference for Hydrogen Compatibility of Materials Hydrogen Battery Abuse Testing Laboratory Center for Infrastructure Research and Innovation Combustion Research Facility Joint BioEnergy Institute Close Energy Research Programs ARPA-E Basic Energy Sciences Materials

  9. Agricultural Structures, Volume II.

    ERIC Educational Resources Information Center

    Linhardt, Richard E.; Burhoe, Steve

    This guide to a curriculum unit in agricultural structures is designed to expand the curriculum materials available in vocational agriculture in Missouri. It and Agricultural Structures I (see note) provide reference materials to systematize the curriculum. The six units cover working with concrete (19 lessons, 2 laboratory exercises), drawing and…

  10. Characterisation of a natural quartz crystal as a reference material for microanalytical determination of Ti, Al, Li, Fe, Mn, Ga and Ge

    USGS Publications Warehouse

    Audetat, Andreas; Garbe-Schonberg, Dieter; Kronz, Andreas; Pettke, Thomas; Rusk, Brian G.; Donovan, John J.; Lowers, Heather

    2015-01-01

    A natural smoky quartz crystal from Shandong province, China, was characterised by laser ablation ICP-MS, electron probe microanalysis (EPMA) and solution ICP-MS to determine the concentration of twenty-four trace and ultra trace elements. Our main focus was on Ti quantification because of the increased use of this element for titanium-in-quartz (TitaniQ) thermobarometry. Pieces of a uniform growth zone of 9 mm thickness within the quartz crystal were analysed in four different LA-ICP-MS laboratories, three EPMA laboratories and one solution-ICP-MS laboratory. The results reveal reproducible concentrations of Ti (57 ± 4 μg g-1), Al (154 ± 15 μg g-1), Li (30 ± 2 μg g-1), Fe (2.2 ± 0.3 μg g-1), Mn (0.34 ± 0.04 μg g-1), Ge (1.7 ± 0.2 μg g-1) and Ga (0.020 ± 0.002 μg g-1) and detectable, but less reproducible, concentrations of Be, B, Na, Cu, Zr, Sn and Pb. Concentrations of K, Ca, Sr, Mo, Ag, Sb, Ba and Au were below the limits of detection of all three techniques. The uncertainties on the average concentration determinations by multiple techniques and laboratories for Ti, Al, Li, Fe, Mn, Ga and Ge are low; hence, this quartz can serve as a reference material or a secondary reference material for microanalytical applications involving the quantification of trace elements in quartz.

  11. Requirements for the Development of Bacillus Anthracis Spore Reference Materials Used to Test Detection Systems

    PubMed Central

    Almeida, Jamie L.; Wang, Lili; Morrow, Jayne B.; Cole, Kenneth D.

    2006-01-01

    Bacillus anthracis spores have been used as biological weapons and the possibility of their further use requires surveillance systems that can accurately and reliably detect their presence in the environment. These systems must collect samples from a variety of matrices, process the samples, and detect the spores. The processing of the sample may include removal of inhibitors, concentration of the target, and extraction of the target in a form suitable for detection. Suitable reference materials will allow the testing of each of these steps to determine the sensitivity and specificity of the detection systems. The development of uniform and well-characterized reference materials will allow the comparison of different devices and technologies as well as assure the continued performance of detection systems. This paper discusses the special requirements of reference materials for Bacillus anthracis spores that could be used for testing detection systems. The detection of Bacillus anthracis spores is based on recognition of specific characteristics (markers) on either the spore surface or in the nucleic acids (DNA). We have reviewed the specific markers and their relevance to characterization of reference materials. We have also included the approach for the characterization of candidate reference materials that we are developing at the NIST laboratories. Additional applications of spore reference materials would include testing sporicidal treatments, techniques for sampling the environment, and remediation of spore-contaminated environments. PMID:27274929

  12. Compositional analysis of biomass reference materials: Results from an interlaboratory study

    DOE PAGES

    Templeton, David W.; Wolfrum, Edward J.; Yen, James H.; ...

    2015-10-29

    Biomass compositional methods are used to compare different lignocellulosic feedstocks, to measure component balances around unit operations and to determine process yields and therefore the economic viability of biomass-to-biofuel processes. Four biomass reference materials (RMs NIST 8491–8494) were prepared and characterized, via an interlaboratory comparison exercise in the early 1990s to evaluate biomass summative compositional methods, analysts, and laboratories. Having common, uniform, and stable biomass reference materials gives the opportunity to assess compositional data compared to other analysts, to other labs, and to a known compositional value. The expiration date for the original characterization of these RMs was reached andmore » an effort to assess their stability and recharacterize the reference values for the remaining material using more current methods of analysis was initiated. We sent samples of the four biomass RMs to 11 academic, industrial, and government laboratories, familiar with sulfuric acid compositional methods, for recharacterization of the component reference values. In this work, we have used an expanded suite of analytical methods that are more appropriate for herbaceous feedstocks, to recharacterize the RMs’ compositions. We report the median values and the expanded uncertainty values for the four RMs on a dry-mass, whole-biomass basis. The original characterization data has been recalculated using median statistics to facilitate comparisons with this data. We found improved total component closures for three out of the four RMs compared to the original characterization, and the total component closures were near 100 %, which suggests that most components were accurately measured and little double counting occurred. Here, the major components were not statistically different in the recharacterization which suggests that the biomass materials are stable during storage and that additional components, not seen in the original characterization, were quantified here.« less

  13. The Optics and Alignment of the Divergent Beam Laboratory X-ray Powder Diffractometer and its Calibration Using NIST Standard Reference Materials.

    PubMed

    Cline, James P; Mendenhall, Marcus H; Black, David; Windover, Donald; Henins, Albert

    2015-01-01

    The laboratory X-ray powder diffractometer is one of the primary analytical tools in materials science. It is applicable to nearly any crystalline material, and with advanced data analysis methods, it can provide a wealth of information concerning sample character. Data from these machines, however, are beset by a complex aberration function that can be addressed through calibration with the use of NIST Standard Reference Materials (SRMs). Laboratory diffractometers can be set up in a range of optical geometries; considered herein are those of Bragg-Brentano divergent beam configuration using both incident and diffracted beam monochromators. We review the origin of the various aberrations affecting instruments of this geometry and the methods developed at NIST to align these machines in a first principles context. Data analysis methods are considered as being in two distinct categories: those that use empirical methods to parameterize the nature of the data for subsequent analysis, and those that use model functions to link the observation directly to a specific aspect of the experiment. We consider a multifaceted approach to instrument calibration using both the empirical and model based data analysis methods. The particular benefits of the fundamental parameters approach are reviewed.

  14. Preparation and value assignment of standard reference material 968e fat-soluble vitamins, carotenoids, and cholesterol in human serum.

    PubMed

    Thomas, Jeanice B; Duewer, David L; Mugenya, Isaac O; Phinney, Karen W; Sander, Lane C; Sharpless, Katherine E; Sniegoski, Lorna T; Tai, Susan S; Welch, Michael J; Yen, James H

    2012-01-01

    Standard Reference Material 968e Fat-Soluble Vitamins, Carotenoids, and Cholesterol in Human Serum provides certified values for total retinol, γ- and α-tocopherol, total lutein, total zeaxanthin, total β-cryptoxanthin, total β-carotene, 25-hydroxyvitamin D(3), and cholesterol. Reference and information values are also reported for nine additional compounds including total α-cryptoxanthin, trans- and total lycopene, total α-carotene, trans-β-carotene, and coenzyme Q(10). The certified values for the fat-soluble vitamins and carotenoids in SRM 968e were based on the agreement of results from the means of two liquid chromatographic methods used at the National Institute of Standards and Technology (NIST) and from the median of results of an interlaboratory comparison exercise among institutions that participate in the NIST Micronutrients Measurement Quality Assurance Program. The assigned values for cholesterol and 25-hydroxyvitamin D(3) in the SRM are the means of results obtained using the NIST reference method based upon gas chromatography-isotope dilution mass spectrometry and liquid chromatography-isotope dilution tandem mass spectrometry, respectively. SRM 968e is currently one of two available health-related NIST reference materials with concentration values assigned for selected fat-soluble vitamins, carotenoids, and cholesterol in human serum matrix. This SRM is used extensively by laboratories worldwide primarily to validate methods for determining these analytes in human serum and plasma and for assigning values to in-house control materials. The value assignment of the analytes in this SRM will help support measurement accuracy and traceability for laboratories performing health-related measurements in the clinical and nutritional communities.

  15. GSD-1G and MPI-DING Reference Glasses for In Situ and Bulk Isotopic Determination

    USGS Publications Warehouse

    Jochum, K.P.; Wilson, S.A.; Abouchami, W.; Amini, M.; Chmeleff, J.; Eisenhauer, A.; Hegner, E.; Iaccheri, L.M.; Kieffer, B.; Krause, J.; McDonough, W.F.; Mertz-Kraus, R.; Raczek, I.; Rudnick, R.L.; Scholz, Donna K.; Steinhoefel, G.; Stoll, B.; Stracke, A.; Tonarini, S.; Weis, D.; Weis, U.; Woodhead, J.D.

    2011-01-01

    This paper contains the results of an extensive isotopic study of United States Geological Survey GSD-1G and MPI-DING reference glasses. Thirteen different laboratories were involved using high-precision bulk (TIMS, MC-ICP-MS) and microanalytical (LA-MC-ICP-MS, LA-ICP-MS) techniques. Detailed studies were performed to demonstrate the large-scale and small-scale homogeneity of the reference glasses. Together with previously published isotopic data from ten other laboratories, preliminary reference and information values as well as their uncertainties at the 95% confidence level were determined for H, O, Li, B, Si, Ca, Sr, Nd, Hf, Pb, Th and U isotopes using the recommendations of the International Association of Geoanalysts for certification of reference materials. Our results indicate that GSD-1G and the MPI-DING glasses are suitable reference materials for microanalytical and bulk analytical purposes. Ce document contient les r??sultats d'une importante ??tude isotopique des verres de r??f??rence USGS GSD-1G et MPI-DING. Treize laboratoires diff??rents ont particip?? au travers de techniques analytiques de haute pr??cision travaillant soit sur ??chantillon total (TIMS, MC-ICP-MS) soit par microanalyse ??in situ?? (LA-MC-ICP-MS, LA-ICP-MS). ?? 2010 The Authors. Geostandards and Geoanalytical Research ?? 2010 International Association of Geoanalysts.

  16. Round-robin study of arsenic implant dose measurement in silicon by SIMS

    NASA Astrophysics Data System (ADS)

    Simons, D.; Kim, K.; Benbalagh, R.; Bennett, J.; Chew, A.; Gehre, D.; Hasegawa, T.; Hitzman, C.; Ko, J.; Lindstrom, R.; MacDonald, B.; Magee, C.; Montgomery, N.; Peres, P.; Ronsheim, P.; Yoshikawa, S.; Schuhmacher, M.; Stockwell, W.; Sykes, D.; Tomita, M.; Toujou, F.; Won, J.

    2006-07-01

    An international round-robin study was undertaken under the auspices of ISO TC201/SC6 to determine the best analytical conditions and the level of interlaboratory agreement for the determination of the implantation dose of arsenic in silicon by secondary ion mass spectrometry (SIMS). Fifteen SIMS laboratories, as well as two laboratories that performed low energy electron-induced X-ray emission spectrometry (LEXES) and one that made measurements by instrumental neutron activation analysis (INAA) were asked to determine the implanted arsenic doses in three unknown samples using as a comparator NIST Standard Reference Material ® 2134. The use of a common reference material by all laboratories resulted in better interlaboratory agreement than was seen in a previous round-robin that lacked a common comparator. The relative standard deviation among laboratories was less than 4% for the medium-dose sample, but several percent larger for the low- and high-dose samples. The high-dose sample showed a significant difference between point-by-point and average matrix normalization because the matrix signal decreased in the vicinity of the implant peak, as observed in a previous study. The dose from point-by-point normalization was in close agreement with that determined by INAA. No clear difference in measurement repeatability was seen when comparing Si 2- and Si 3- as matrix references with AsSi -.

  17. Characterization of a Recombinant Adeno-Associated Virus Type 2 Reference Standard Material

    PubMed Central

    Lock, Martin; McGorray, Susan; Auricchio, Alberto; Ayuso, Eduard; Beecham, E. Jeffrey; Blouin-Tavel, Véronique; Bosch, Fatima; Bose, Mahuya; Byrne, Barry J.; Caton, Tina; Chiorini, John A.; Chtarto, Abdelwahed; Clark, K. Reed; Conlon, Thomas; Darmon, Christophe; Doria, Monica; Douar, Anne; Flotte, Terence R.; Francis, Joyce D.; Francois, Achille; Giacca, Mauro; Korn, Michael T.; Korytov, Irina; Leon, Xavier; Leuchs, Barbara; Lux, Gabriele; Melas, Catherine; Mizukami, Hiroaki; Moullier, Philippe; Müller, Marcus; Ozawa, Keiya; Philipsberg, Tina; Poulard, Karine; Raupp, Christina; Rivière, Christel; Roosendaal, Sigrid D.; Samulski, R. Jude; Soltys, Steven M.; Surosky, Richard; Tenenbaum, Liliane; Thomas, Darby L.; van Montfort, Bart; Veres, Gabor; Wright, J. Fraser; Xu, Yili; Zelenaia, Olga; Zentilin, Lorena

    2010-01-01

    Abstract A recombinant adeno-associated virus serotype 2 Reference Standard Material (rAAV2 RSM) has been produced and characterized with the purpose of providing a reference standard for particle titer, vector genome titer, and infectious titer for AAV2 gene transfer vectors. Production and purification of the reference material were carried out by helper virus–free transient transfection and chromatographic purification. The purified bulk material was vialed, confirmed negative for microbial contamination, and then distributed for characterization along with standard assay protocols and assay reagents to 16 laboratories worldwide. Using statistical transformation and modeling of the raw data, mean titers and confidence intervals were determined for capsid particles ({X}, 9.18 × 1011 particles/ml; 95% confidence interval [CI], 7.89 × 1011 to 1.05 × 1012 particles/ml), vector genomes ({X}, 3.28 × 1010 vector genomes/ml; 95% CI, 2.70 × 1010 to 4.75 × 1010 vector genomes/ml), transducing units ({X}, 5.09 × 108 transducing units/ml; 95% CI, 2.00 × 108 to 9.60 × 108 transducing units/ml), and infectious units ({X}, 4.37 × 109 TCID50 IU/ml; 95% CI, 2.06 × 109 to 9.26 × 109 TCID50 IU/ml). Further analysis confirmed the identity of the reference material as AAV2 and the purity relative to nonvector proteins as greater than 94%. One obvious trend in the quantitative data was the degree of variation between institutions for each assay despite the relatively tight correlation of assay results within an institution. This relatively poor degree of interlaboratory precision and accuracy was apparent even though attempts were made to standardize the assays by providing detailed protocols and common reagents. This is the first time that such variation between laboratories has been thoroughly documented and the findings emphasize the need in the field for universal reference standards. The rAAV2 RSM has been deposited with the American Type Culture Collection and is available to the scientific community to calibrate laboratory-specific internal titer standards. Anticipated uses of the rAAV2 RSM are discussed. PMID:20486768

  18. An expanded safeguards role for the DOE safeguards analytical laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bingham, C.D.

    The New Brunswick Laboratory (NBL) is a Government-owned, Government-operated (GOGO) laboratory, with the mission to provide and maintain a nuclear material measurements and standards laboratory. The functional responsibilities of NBL serve as a technical response to the statutory responsibility of the Department of Energy (DOE) to assure the safeguarding of nuclear materials. In the execution of its mission, NBL carries out activities in six safeguards-related programs: measurement development, measurement evaluation, measurement services, safeguards assessment, reference and calibration materials and site-specific assistance. These program activities have been implemented by NBL for many years; their relative emphases, however, have been changed recentlymore » to address the priorities defined by the DOE Office of Safeguards and Security, Defense Programs (OSS/DP). As a consequence, NBL operations are in the ''mainstream'' of domestic safeguards activities. This expanded safeguards role for NBL is discussed in this paper.« less

  19. Characterization of Lone Pine, California, tremolite asbestos and preparation of research material

    USGS Publications Warehouse

    Harper, Martin; Van Gosen, Bradley S.; Crankshaw, Owen S; Doorn, Stacy S; Ennis, J. Todd; Harrison, Sara E

    2014-01-01

    Well-characterized amphibole asbestos mineral samples are required for use as analytical standards and in future research projects. Currently, the National Institute for Standards and Technology Standard Reference Material samples of asbestos are listed as ‘Discontinued’. The National Institute for Occupational Safety and Health (NIOSH) has a goal under the Asbestos Roadmap of locating and characterizing research materials for future use. Where an initial characterization analysis determines that a collected material is appropriate for use as a research material in terms of composition and asbestiform habit, sufficient amounts of the material will be collected to make it publicly available. An abandoned mine near Lone Pine, California, contains a vein of tremolite asbestos, which was the probable source of a reference material that has been available for the past 17 years from the Health and Safety Laboratory (HSL) in the UK. Newly collected fibrous vein material from this mine was analyzed at Research Triangle Institute (RTI International) with some additional analysis by the US Geological Survey’s Denver Microbeam Laboratory. The analysis at RTI International included: (i) polarized light microscopy (PLM) with a determination of principal optical properties; (ii) X-ray diffraction; (iii) transmission electron microscopy, including energy dispersive X-ray spectroscopy and selected-area electron diffraction; and (iv) spindle stage analysis using PLM to determine whether individual fibers and bundles of the samples were polycrystalline or single-crystal cleavage fragments. The overall findings of the study indicated that the material is tremolite asbestos with characteristics substantially similar to the earlier distributed HSL reference material. A larger quantity of material was prepared by sorting, acid-washing and mixing for sub-division into vials of ~10g each. These vials have been transferred from NIOSH to RTI International, from where they can be obtained on request.

  20. Characterization of Lone Pine, California, Tremolite Asbestos and Preparation of Research Material

    PubMed Central

    Harper, Martin; Van Gosen, Bradley; Crankshaw, Owen S.; Doorn, Stacy S.; Ennis, Todd J.; Harrison, Sara E.

    2016-01-01

    Well-characterized amphibole asbestos mineral samples are required for use as analytical standards and in future research projects. Currently, the National Institute for Standards and Technology Standard Reference Material samples of asbestos are listed as ‘Discontinued’. The National Institute for Occupational Safety and Health (NIOSH) has a goal under the Asbestos Roadmap of locating and characterizing research materials for future use. Where an initial characterization analysis determines that a collected material is appropriate for use as a research material in terms of composition and asbestiform habit, sufficient amounts of the material will be collected to make it publicly available. An abandoned mine near Lone Pine, California, contains a vein of tremolite asbestos, which was the probable source of a reference material that has been available for the past 17 years from the Health and Safety Laboratory (HSL) in the UK. Newly collected fibrous vein material from this mine was analyzed at Research Triangle Institute (RTI International) with some additional analysis by the US Geological Survey’s Denver Microbeam Laboratory. The analysis at RTI International included: (i) polarized light microscopy (PLM) with a determination of principal optical properties; (ii) X-ray diffraction; (iii) transmission electron microscopy, including energy dispersive X-ray spectroscopy and selected-area electron diffraction; and (iv) spindle stage analysis using PLM to determine whether individual fibers and bundles of the samples were polycrystalline or single-crystal cleavage fragments. The overall findings of the study indicated that the material is tremolite asbestos with characteristics substantially similar to the earlier distributed HSL reference material. A larger quantity of material was prepared by sorting, acid-washing and mixing for sub-division into vials of ~10 g each. These vials have been transferred from NIOSH to RTI International, from where they can be obtained on request. PMID:25268000

  1. CIVIL TECHNOLOGY, HIGHWAY AND STRUCTURAL OPTIONS, A SUGGESTED 2-YEAR POST HIGH SCHOOL CURRICULUM. TECHNICAL EDUCATION PROGRAM SERIES, NUMBER 8.

    ERIC Educational Resources Information Center

    BEAUMONT, JOHN A; AND OTHERS

    DESIGNED TO ASSIST ADMINISTRATORS, SUPERVISORS, AND TEACHERS TO PLAN, DEVELOP, AND EVALUATE PROGRAMS, THIS CURRICULUM GUIDE OFFERS COURSE OUTLINES, PROCEDURES, LABORATORY LAYOUTS, TEXTS AND REFERENCES, LISTS OF LABORATORY EQUIPMENT AND ITS COST, AND A SELECTED LIST OF SCIENTIFIC AND TECHNICAL SOCIETIES. BASIC MATERIALS WERE PREPARED AT THE…

  2. Determination of total carbohydrates in wine and wine-like beverages by HPLC with a refractive index detector: First Action 2013.12.

    PubMed

    Kupina, Steve; Roman, Mark

    2014-01-01

    An international collaborative study was conducted of an HPLC-refractive index (RI) detector method for the determination of the combined amounts of sugars, glycerol, organic acids, and phenolic compounds in wines and wine-like beverages. Nine collaborating laboratories representing major winery, contract laboratories, and government laboratories tested eight different materials as blind duplicates using the proposed method. Sample materials included red and white wines, port, wine cooler, and nonalcoholic wine. One material was a negative control, and one material was a reference material. Samples were either treated with an ion-exchange resin to remove interfering organic acids prior to analysis or left untreated to include organic acids and phenolics. Red wine samples were treated with polyvinylpolypyrrolidone to remove potential interferences from phenolics prior to analysis. The HPLC analyses were performed on a Bio-Rad Fast Acid Analysis Column using RI detection. Reproducibility (RSD(R)) for untreated samples (sugars + phenolics + organic acids) ranged from 6.6% for Titrivin AA4 reference material to 11.0% for dry red wine. RSD(R) for treated samples (sugars only) ranged from 6.8% for white zinfandel to 18.9% for dry white wine. RSD(R) for treated samples (sugars only) + glycerol ranged from 6.4% for white zinfandel to 19.8% for dry red wine. Based on these results, the method was adopted as Official First Action status for determination of total carbohydrates in wine and wine-like beverages.

  3. Quality-control materials in the USDA National Food and Nutrient Analysis Program (NFNAP).

    PubMed

    Phillips, Katherine M; Patterson, Kristine Y; Rasor, Amy S; Exler, Jacob; Haytowitz, David B; Holden, Joanne M; Pehrsson, Pamela R

    2006-03-01

    The US Department of Agriculture (USDA) Nutrient Data Laboratory (NDL) develops and maintains the USDA National Nutrient Databank System (NDBS). Data are released from the NDBS for scientific and public use through the USDA National Nutrient Database for Standard Reference (SR) ( http://www.ars.usda.gov/ba/bhnrc/ndl ). In 1997 the NDL initiated the National Food and Nutrient Analysis Program (NFNAP) to update and expand its food-composition data. The program included: 1) nationwide probability-based sampling of foods; 2) central processing and archiving of food samples; 3) analysis of food components at commercial, government, and university laboratories; 4) incorporation of new analytical data into the NDBS; and 5) dissemination of these data to the scientific community. A key feature and strength of the NFNAP was a rigorous quality-control program that enabled independent verification of the accuracy and precision of analytical results. Custom-made food-control composites and/or commercially available certified reference materials were sent to the laboratories, blinded, with the samples. Data for these materials were essential to ongoing monitoring of analytical work, to identify and resolve suspected analytical problems, to ensure the accuracy and precision of results for the NFNAP food samples.

  4. Preparation of a sewage sludge laboratory quality control material for butyltin compounds and their determination by isotope-dilution mass spectrometry.

    PubMed

    Zuliani, Tea; Milačič, Radmila; Ščančar, Janez

    2012-05-01

    The characterisation of a laboratory quality control material (QCM) for dibutyltin (DBT) and tributyltin (TBT) in sewage sludge is described. The reference values were determined by the use of two different types of isotope-dilution mass spectrometry: gas chromatography-mass spectrometry and gas chromatography-inductively coupled plasma mass spectrometry. To avoid possible analytical errors such as non-quantitative extraction and species degradation during sample preparation, different extraction methods were tested (microwave- and ultrasound-assisted extraction and mechanical stirring). The reference values were based on the unweighted means of results from the homogenisation and characterisation studies. The reference values obtained were 1,553 ± 87 and 534 ± 38 ng Sn g(-1) for DBT and TBT, respectively. In the uncertainty budget estimation, the sample inhomogeneity and between-method imprecision were taken into account. The concentrations of DBT and TBT in QCM are similar to those in the harbour sediment certified reference material PACS-2. Likewise, the levels of DBT and TBT are in the range of these compounds normally present in sewage sludge worldwide. In the future, the QCM will be used for an intercomparison study on DBT and TBT in sewage sludge, and as a day-to-day QCM during studies concerning the application of sewage sludge as an additive to artificial soil or as a raw material in civil engineering construction.

  5. Standard reference material for Her2 testing: report of a National Institute of Standards and Technology-sponsored Consensus Workshop.

    PubMed

    Hammond, M Elizabeth H; Barker, Peter; Taube, Sheila; Gutman, Steven

    2003-06-01

    A workshop was sponsored by the National Institute of Standards and Technology, the Cancer Diagnosis Program of the National Cancer Institute, the Food and Drug Administration, and the College of American Pathologists to address the need for a reference material for Her2 gene protein testing. It was agreed that such a standard was desirable and necessary to ensure the reliability of Her2 testing to qualify patients for trastuzumab therapy. Two standards consisting of well characterized cell lines will be produced, 1 that will be a National Institute of Standards and Technology-certifiable standard, and 1 that will be a commercially developed standard for use in all Her2 testing. It was also agreed that all Her2 testing must be performed on samples fixed only in 10% buffered formalin, as specified in the Food and Drug Administration-approved testing methods. Participants agreed to plan strategies to educate pathologists, clinicians, and laboratories about the need and use of such a standard. A National Committee for Clinical Laboratory Standards guideline for the use of the standard reference material will be created to facilitate this process.

  6. Reduction of Effective Acceleration to Microgravity Levels

    NASA Technical Reports Server (NTRS)

    Downey, James P.

    2000-01-01

    Acceleration due to earth's gravity causes buoyancy driven convection and sedimentation in solutions. In addition. pressure gradients occur as a function of the height within a liquid column. Hence gravity effects both equilbria conditions and phase transitions as a result of hydrostatic pressure gradients. The affect of gravity on the rate of heat and man transfer in solutal processes can be particularly important in polymer processing due to the high sensitivity of polymeric materials to processing conditions. The term microgravity has been coined to describe an environment in which the affects of gravitational acceleration am greatly reduced. It may seem odd to talk in term of reducing the effects of gravitational acceleration since gravitational attraction is a basic property of matter. However, die presence of gravity on in situ processing or measurements can be negated by achieving conditions in which the laboratory, or more specifically the container of the experimental materials, a subjected to the same acceleration as the materials themselves. With regard to the laboratory reference frame, there is virtually no force on the experimental solutions. This is difficult to achieve but can be done. A short review of Newtonian physics provides an explanation on both how processes we affected by gravity and how microgravity conditions are achieved. The fact that fluids deform when subject to a force bid solids do not indicates that solids have a structure able to exert an opposing force that negates an externally applied force. Liquids deform when a force is applied, indicating that a liquid structure cannot completely negate an applied force. Just how easily a liquid resists deformation is related to its viscosity. Spaceflight provides an environment in which the laboratory reference frame i.e. the spacecraft and all the equipment therein an experiencing virtually identical forces. There is no solid foundation underneath such a laboratory, so the laboratory accelerates according to the force of gravity as do the experimental fluids within the lab. Hence, the magnitude of the form excited by the laboratory on the experimental solutions within are greatly reduced. When compared with a laboratory on the ground and averaged over time, the fluids in a spaceflight laboratory experience approximately a 10 (sup -6)decrease in acceleration relative to their laboratory reference frame hence the term microgravity.

  7. Atomic spectrometry and trends in clinical laboratory medicine

    NASA Astrophysics Data System (ADS)

    Parsons, Patrick J.; Barbosa, Fernando

    2007-09-01

    Increasing numbers of clinical laboratories are transitioning away from flame and electrothermal AAS methods to those based on ICP-MS. Still, for many laboratories, the choice of instrumentation is based upon (a) the element(s) to be determined, (b) the matrix/matrices to be analyzed, and (c) the expected concentration(s) of the analytes in the matrix. Most clinical laboratories specialize in measuring Se, Zn, Cu, and Al in serum, and/or Pb, Cd, Hg, As, and Cr in blood and/or urine, while other trace elements (e.g., Pt, Au etc.) are measured for therapeutic purposes. Quantitative measurement of elemental species is becoming more widely accepted for nutritional and/or toxicological screening purposes, and ICP-MS interfaced with separation techniques, such as liquid chromatography or capillary electrophoresis, offers the advantage of on-line species determination coupled with very low detection limits. Polyatomic interferences for some key elements such as Se, As, and Cr require instrumentation equipped with dynamic reaction cell or collision cell technologies, or might even necessitate the use of sector field ICP-MS, to assure accurate results. Nonetheless, whatever analytical method is selected for the task, careful consideration must be given both to specimen collection procedures and to the control of pre-analytical variables. Finally, all methods benefit from access to reliable certified reference materials (CRMs). While a variety of reference materials (RMs) are available for trace element measurements in clinical matrices, not all can be classified as CRMs. The major metrological organizations (e.g., NIST, IRMM, NIES) provide a limited number of clinical CRMs, however, secondary reference materials are readily available from commercial organizations and organizers of external quality assessment schemes.

  8. Characterization of 137 Genomic DNA Reference Materials for 28 Pharmacogenetic Genes

    PubMed Central

    Pratt, Victoria M.; Everts, Robin E.; Aggarwal, Praful; Beyer, Brittany N.; Broeckel, Ulrich; Epstein-Baak, Ruth; Hujsak, Paul; Kornreich, Ruth; Liao, Jun; Lorier, Rachel; Scott, Stuart A.; Smith, Chingying Huang; Toji, Lorraine H.; Turner, Amy; Kalman, Lisa V.

    2017-01-01

    Pharmacogenetic testing is increasingly available from clinical laboratories. However, only a limited number of quality control and other reference materials are currently available to support clinical testing. To address this need, the Centers for Disease Control and Prevention–based Genetic Testing Reference Material Coordination Program, in collaboration with members of the pharmacogenetic testing community and the Coriell Cell Repositories, has characterized 137 genomic DNA samples for 28 genes commonly genotyped by pharmacogenetic testing assays (CYP1A1, CYP1A2, CYP2A6, CYP2B6, CYP2C8, CYP2C9, CYP2C19, CYP2D6, CYP2E1, CYP3A4, CYP3A5, CYP4F2, DPYD, GSTM1, GSTP1, GSTT1, NAT1, NAT2, SLC15A2, SLC22A2, SLCO1B1, SLCO2B1, TPMT, UGT1A1, UGT2B7, UGT2B15, UGT2B17, and VKORC1). One hundred thirty-seven Coriell cell lines were selected based on ethnic diversity and partial genotype characterization from earlier testing. DNA samples were coded and distributed to volunteer testing laboratories for targeted genotyping using a number of commercially available and laboratory developed tests. Through consensus verification, we confirmed the presence of at least 108 variant pharmacogenetic alleles. These samples are also being characterized by other pharmacogenetic assays, including next-generation sequencing, which will be reported separately. Genotyping results were consistent among laboratories, with most differences in allele assignments attributed to assay design and variability in reported allele nomenclature, particularly for CYP2D6, UGT1A1, and VKORC1. These publicly available samples will help ensure the accuracy of pharmacogenetic testing. PMID:26621101

  9. A manual for a laboratory information management system (LIMS) for light stable isotopes

    USGS Publications Warehouse

    Coplen, Tyler B.

    1997-01-01

    The reliability and accuracy of isotopic data can be improved by utilizing database software to (i) store information about samples, (ii) store the results of mass spectrometric isotope-ratio analyses of samples, (iii) calculate analytical results using standardized algorithms stored in a database, (iv) normalize stable isotopic data to international scales using isotopic reference materials, and (v) generate multi-sheet paper templates for convenient sample loading of automated mass-spectrometer sample preparation manifolds. Such a database program is presented herein. Major benefits of this system include (i) an increase in laboratory efficiency, (ii) reduction in the use of paper, (iii) reduction in workload due to the elimination or reduction of retyping of data by laboratory personnel, and (iv) decreased errors in data reported to sample submitters. Such a database provides a complete record of when and how often laboratory reference materials have been analyzed and provides a record of what correction factors have been used through time. It provides an audit trail for stable isotope laboratories. Since the original publication of the manual for LIMS for Light Stable Isotopes, the isotopes 3 H, 3 He, and 14 C, and the chlorofluorocarbons (CFCs), CFC-11, CFC-12, and CFC-113, have been added to this program.

  10. A manual for a Laboratory Information Management System (LIMS) for light stable isotopes

    USGS Publications Warehouse

    Coplen, Tyler B.

    1998-01-01

    The reliability and accuracy of isotopic data can be improved by utilizing database software to (i) store information about samples, (ii) store the results of mass spectrometric isotope-ratio analyses of samples, (iii) calculate analytical results using standardized algorithms stored in a database, (iv) normalize stable isotopic data to international scales using isotopic reference materials, and (v) generate multi-sheet paper templates for convenient sample loading of automated mass-spectrometer sample preparation manifolds. Such a database program is presented herein. Major benefits of this system include (i) an increase in laboratory efficiency, (ii) reduction in the use of paper, (iii) reduction in workload due to the elimination or reduction of retyping of data by laboratory personnel, and (iv) decreased errors in data reported to sample submitters. Such a database provides a complete record of when and how often laboratory reference materials have been analyzed and provides a record of what correction factors have been used through time. It provides an audit trail for stable isotope laboratories. Since the original publication of the manual for LIMS for Light Stable Isotopes, the isotopes 3 H, 3 He, and 14 C, and the chlorofluorocarbons (CFCs), CFC-11, CFC-12, and CFC-113, have been added to this program.

  11. Multicomponent blood lipid analysis by means of near infrared spectroscopy, in geese.

    PubMed

    Bazar, George; Eles, Viktoria; Kovacs, Zoltan; Romvari, Robert; Szabo, Andras

    2016-08-01

    This study provides accurate near infrared (NIR) spectroscopic models on some laboratory determined clinicochemical parameters (i.e. total lipid (5.57±1.95 g/l), triglyceride (2.59±1.36 mmol/l), total cholesterol (3.81±0.68 mmol/l), high density lipoprotein (HDL) cholesterol (2.45±0.58 mmol/l)) of blood serum samples of fattened geese. To increase the performance of multivariate chemometrics, samples significantly deviating from the regression models implying laboratory error were excluded from the final calibration datasets. Reference data of excluded samples having outlier spectra in principal component analysis were not marked as false. Samples deviating from the regression models but having non outlier spectra in PCA were identified as having false reference constituent values. Based on the NIR selection methods, 5% of the reference measurement data were rated as doubtful. The achieved models reached R(2) of 0.864, 0.966, 0.850, 0.793, and RMSE of 0.639 g/l, 0.232 mmol/l, 0.210 mmol/l, 0.241 mmol/l for total lipid, triglyceride, total cholesterol and HDL cholesterol, respectively, during independent validation. Classical analytical techniques focus on single constituents and often require chemicals, time-consuming measurements, and experienced technicians. NIR technique provides a quick, cost effective, non-hazardous alternative method for analysis of several constituents based on one single spectrum of each sample, and it also offers the possibility for looking at the laboratory reference data critically. Evaluation of reference data to identify and exclude falsely analyzed samples can provide warning feedback to the reference laboratory, especially in the case of analyses where laboratory methods are not perfectly suited to the subjected material and there is an increased chance of laboratory error. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Stormwater Pollution Prevention Plan - TA-60 Material Recycling Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sandoval, Leonard Frank

    This Storm Water Pollution Prevention Plan (SWPPP) was developed in accordance with the provisions of the Clean Water Act (33 U.S.C. §§1251 et seq., as amended), and the Multi-Sector General Permit for Storm Water Discharges Associated with Industrial Activity (U.S. EPA, June 2015) issued by the U.S. Environmental Protection Agency (EPA) for the National Pollutant Discharge Elimination System (NPDES) and using the industry specific permit requirements for Sector P-Land Transportation and Warehousing as a guide. This SWPPP applies to discharges of stormwater from the operational areas of the TA- 60 Material Recycling Facility at Los Alamos National Laboratory. Los Alamosmore » National Laboratory (also referred to as LANL or the “Laboratory”) is owned by the Department of Energy (DOE), and is operated by Los Alamos National Security, LLC (LANS). Throughout this document, the term “facility” refers to the TA-60 Material Recycling Facility. The current permit expires at midnight on June 4, 2020.« less

  13. The Second National Ballistics Imaging Comparison (NBIC-2)

    PubMed Central

    Vorburger, TV; Yen, J; Song, JF; Thompson, RM; Renegar, TB; Zheng, A; Tong, M; Ols, M

    2014-01-01

    In response to the guidelines issued by the American Society of Crime Laboratory Directors/Laboratory Accreditation Board (ASCLD/LAB-International) to establish traceability and quality assurance in U.S. crime laboratories, NIST and the ATF initiated a joint project, entitled the National Ballistics Imaging Comparison (NBIC). The NBIC project aims to establish a national traceability and quality system for ballistics identifications in crime laboratories utilizing ATF’s National Integrated Ballistics Information Network (NIBIN). The original NBIC was completed in 2010. In the second NBIC, NIST Standard Reference Material (SRM) 2461 Cartridge Cases were used as reference standards, and 14 experts from 11 U.S. crime laboratories each performed 17 image acquisitions and correlations of the SRM cartridge cases over the course of about half a year. Resulting correlation scores were collected by NIST for statistical analyses, from which control charts and control limits were developed for the proposed quality system and for promoting future assessments and accreditations for firearm evidence in U.S. forensic laboratories in accordance with the ISO 17025 Standard. PMID:26601051

  14. The Second National Ballistics Imaging Comparison (NBIC-2).

    PubMed

    Vorburger, T V; Yen, J; Song, J F; Thompson, R M; Renegar, T B; Zheng, A; Tong, M; Ols, M

    2014-01-01

    In response to the guidelines issued by the American Society of Crime Laboratory Directors/Laboratory Accreditation Board (ASCLD/LAB-International) to establish traceability and quality assurance in U.S. crime laboratories, NIST and the ATF initiated a joint project, entitled the National Ballistics Imaging Comparison (NBIC). The NBIC project aims to establish a national traceability and quality system for ballistics identifications in crime laboratories utilizing ATF's National Integrated Ballistics Information Network (NIBIN). The original NBIC was completed in 2010. In the second NBIC, NIST Standard Reference Material (SRM) 2461 Cartridge Cases were used as reference standards, and 14 experts from 11 U.S. crime laboratories each performed 17 image acquisitions and correlations of the SRM cartridge cases over the course of about half a year. Resulting correlation scores were collected by NIST for statistical analyses, from which control charts and control limits were developed for the proposed quality system and for promoting future assessments and accreditations for firearm evidence in U.S. forensic laboratories in accordance with the ISO 17025 Standard.

  15. Methods for Analysis and Simulation of Ballistic Impact

    DTIC Science & Technology

    2017-04-01

    ARL-RP-0597 ● Apr 2017 US Army Research Laboratory Methods for Analysis and Simulation of Ballistic Impact by John D Clayton...Laboratory Methods for Analysis and Simulation of Ballistic Impact by John D Clayton Weapons and Materials Research Directorate, ARL...analytical, and numerical methods of ballistics research . Similar lengthy references dealing with pertinent aspects include [8, 9]. In contrast, the

  16. Annotated bibliography of Software Engineering Laboratory literature

    NASA Technical Reports Server (NTRS)

    Morusiewicz, Linda; Valett, Jon D.

    1991-01-01

    An annotated bibliography of technical papers, documents, and memorandums produced by or related to the Software Engineering Laboratory is given. More than 100 publications are summarized. These publications cover many areas of software engineering and range from research reports to software documentation. All materials have been grouped into eight general subject areas for easy reference: The Software Engineering Laboratory; The Software Engineering Laboratory: Software Development Documents; Software Tools; Software Models; Software Measurement; Technology Evaluations; Ada Technology; and Data Collection. Subject and author indexes further classify these documents by specific topic and individual author.

  17. Annotated bibliography of software engineering laboratory literature

    NASA Technical Reports Server (NTRS)

    Buhler, Melanie; Valett, Jon

    1989-01-01

    An annotated bibliography is presented of technical papers, documents, and memorandums produced by or related to the Software Engineering Laboratory. The bibliography was updated and reorganized substantially since the original version (SEL-82-006, November 1982). All materials were grouped into eight general subject areas for easy reference: (1) The Software Engineering Laboratory; (2) The Software Engineering Laboratory: Software Development Documents; (3) Software Tools; (4) Software Models; (5) Software Measurement; (6) Technology Evaluations; (7) Ada Technology; and (8) Data Collection. Subject and author indexes further classify these documents by specific topic and individual author.

  18. Oxygen isotopes in nitrate: New reference materials for 18O:17O:16O measurements and observations on nitrate-water equilibration

    USGS Publications Warehouse

    Böhlke, J.K.; Mroczkowski, S.J.; Coplen, T.B.

    2003-01-01

    Despite a rapidly growing literature on analytical methods and field applications of O isotope-ratio measurements of NO3− in environmental studies, there is evidence that the reported data may not be comparable because reference materials with widely varying δ18O values have not been readily available. To address this problem, we prepared large quantities of two nitrate salts with contrasting O isotopic compositions for distribution as reference materials for O isotope-ratio measurements: USGS34 (KNO3) with low δ18O and USGS35 (NaNO3) with high δ18O and ‘mass-independent’ δ17O. The procedure used to produce USGS34 involved equilibration of HNO3 with 18O-depleted meteoric water. Nitric acid equilibration is proposed as a simple method for producing laboratory NO3− reference materials with a range of δ18O values and normal (mass-dependent) 18O:17O:16O variation. Preliminary data indicate that the equilibrium O isotope-fractionation factor (α) between [NO3−] and H2O decreases with increasing temperature from 1.0215 at 22°C to 1.0131 at 100°C. USGS35 was purified from the nitrate ore deposits of the Atacama Desert in Chile and has a high 17O:18O ratio owing to its atmospheric origin. These new reference materials, combined with previously distributed NO3− isotopic reference materials IAEA-N3 (=IAEA-NO-3) and USGS32, can be used to calibrate local laboratory reference materials for determining offset values, scale factors, and mass-independent effects on N and O isotope-ratio measurements in a wide variety of environmental NO3− samples. Preliminary analyses yield the following results (normalized with respect to VSMOW and SLAP, with reproducibilities of ±0.2–0.3‰, 1σ): IAEA-N3 has δ18O = +25.6‰ and δ17O = +13.2‰; USGS32 has δ18O = +25.7‰; USGS34 has δ18O = −27.9‰ and δ17O = −14.8‰; and USGS35 has δ18O = +57.5‰ and δ17O = +51.5‰.

  19. delta 15N and non-carbonate delta 13C values for two petroleum source rock reference materials and a marine sediment reference material

    USGS Publications Warehouse

    Dennen, Kristin O.; Johnson, Craig A.; Otter, Marshall L.; Silva, Steven R.; Wandless, Gregory A.

    2006-01-01

    Samples of United States Geological Survey (USGS) Certified Reference Materials USGS Devonian Ohio Shale (SDO-1), and USGS Eocene Green River Shale (SGR-1), and National Research Council Canada (NRCC) Certified Marine Sediment Reference Material (PACS-2), were sent for analysis to four separate analytical laboratories as blind controls for organic rich sedimentary rock samples being analyzed from the Red Dog mine area in Alaska. The samples were analyzed for stable isotopes of carbon (delta13Cncc) and nitrogen (delta15N), percent non-carbonate carbon (Wt % Cncc) and percent nitrogen (Wt % N). SDO-1, collected from the Huron Member of the Ohio Shale, near Morehead, Kentucky, and SGR-1, collected from the Mahogany zone of the Green River Formation are petroleum source rocks used as reference materials for chemical analyses of sedimentary rocks. PACS-2 is modern marine sediment collected from the Esquimalt, British Columbia harbor. The results presented in this study are, with the exceptions noted below, the first published for these reference materials. There are published information values for the elemental concentrations of 'organic' carbon (Wt % Corg measured range is 8.98 - 10.4) and nitrogen (Wt % Ntot 0.347 with SD 0.043) only for SDO-1. The suggested values presented here should be considered 'information values' as defined by the NRCC Institute for National Measurement Reference Materials and should be useful for the analysis of 13C, 15N, C and N in organic material in sedimentary rocks.

  20. Ultra-Low Level Plutonium Isotopes in the NIST SRM 4355A (Peruvian Soil-1)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Inn, Kenneth G.; LaRosa, Jerome; Nour, Svetlana

    2009-05-31

    For more than 20 years, countries and their agencies which monitor discharge sites and storage facilities have relied on the National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 4355 Peruvian Soil reference material. Its low fallout contamination makes it an ideal soil blank for measurements associated with terrestrial pathway to man studies. Presently, SRM 4355 is out of stock, and a new batch of the Peruvian soil is currently under development as future NIST SRM 4355A. Both environmental radioanalytical laboratories and mass spectrometry communities will benefit from this SRM. The former must assess their laboratory contamination andmore » measurement detection limits by measurement of blank sample material. The Peruvian Soil is so low in anthropogenic radionuclides that it is a suitable virtual blank. On the other hand, mass spectrometric laboratories have high sensitivity instruments that are capable of quantitative isotopic measurements at low plutonium levels of the SRM 4355 (first Peruvian Soil SRM) that provided the mass spectrometric community with the calibration, quality control, and testing material needed for methods development, and legal defensibility. The quantification of the ultra-low plutonium content in the SRM 4355A was a considerable challenge for the mass spectrometric laboratories. Careful blank control and correction, isobaric interferences, instrument stability, peak assessment, and detection assessment were necessary. Furthermore, a systematic statistical evaluation of the measurement results and considerable discussions with the mass spectroscopy metrologists were needed to derive the certified values and uncertainties. SRM 4355A will provide the mass spectrometric community with the quality control and testing material needed for higher sensitivity methods development, and legal defensibility.« less

  1. Microscale Synthesis and Analysis of a Dipeptide.

    ERIC Educational Resources Information Center

    Blatchly, Richard A.; And Others

    1989-01-01

    Described is a microscale chemistry laboratory in which a dipeptide is synthesized from its component amino acids and analyzed using chiral-phase thin-layer chromatography. Experimental procedures, and materials are discussed. Twelve references are listed. (CW)

  2. The Dot Blot ELISA.

    ERIC Educational Resources Information Center

    Gerbig, Donald G., Jr.; Fenk, Christopher J.; Goodhart, Amy S.

    2000-01-01

    Uses two laboratory techniques, Enzyme Linked Immunosorbent Assay (ELISA) and Western Blot, to demonstrate antibody-antigen binding concepts. Includes a list of required materials and directions for the procedure, and makes suggestions for classroom applications. (Contains 13 references.) (YDS)

  3. Measurement uncertainty: Friend or foe?

    PubMed

    Infusino, Ilenia; Panteghini, Mauro

    2018-02-02

    The definition and enforcement of a reference measurement system, based on the implementation of metrological traceability of patients' results to higher order reference methods and materials, together with a clinically acceptable level of measurement uncertainty, are fundamental requirements to produce accurate and equivalent laboratory results. The uncertainty associated with each step of the traceability chain should be governed to obtain a final combined uncertainty on clinical samples fulfilling the requested performance specifications. It is important that end-users (i.e., clinical laboratory) may know and verify how in vitro diagnostics (IVD) manufacturers have implemented the traceability of their calibrators and estimated the corresponding uncertainty. However, full information about traceability and combined uncertainty of calibrators is currently very difficult to obtain. Laboratory professionals should investigate the need to reduce the uncertainty of the higher order metrological references and/or to increase the precision of commercial measuring systems. Accordingly, the measurement uncertainty should not be considered a parameter to be calculated by clinical laboratories just to fulfil the accreditation standards, but it must become a key quality indicator to describe both the performance of an IVD measuring system and the laboratory itself. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  4. FireWorks curriculum featuring ponderosa, lodgepole, and whitebark pine forests

    Treesearch

    Jane Kapler Smith; Nancy E. McMurray

    2000-01-01

    FireWorks is an educational program for students in grades 1-10. The program consists of the curriculum in this report and a trunk of laboratory materials, specimens, and reference materials. It provides interactive, hands-on activities for studying fire ecology, fire behavior, and the influences of people on three fire-dependent forest types - Pinus ponderosa...

  5. Round-robin 230Th– 234U age dating of bulk uranium for nuclear forensics

    DOE PAGES

    Gaffney, Amy M.; Hubert, Amélie; Kinman, William S.; ...

    2015-07-30

    We report that in an inter-laboratory measurement comparison study, four laboratories determined 230Th– 234U model ages of uranium certified reference material NBL U050 using isotope dilution mass spectrometry. The model dates determined by the participating laboratories range from 9 March 1956 to 19 October 1957, and are indistinguishable given the associated measurement uncertainties. These model ages are concordant with to slightly older than the known production age of NBL U050.

  6. The New Big Science at the NSLS

    NASA Astrophysics Data System (ADS)

    Crease, Robert

    2016-03-01

    The term ``New Big Science'' refers to a phase shift in the kind of large-scale science that was carried out throughout the U.S. National Laboratory system, when large-scale materials science accelerators rather than high-energy physics accelerators became marquee projects at most major basic research laboratories in the post-Cold War era, accompanied by important changes in the character and culture of the research ecosystem at these laboratories. This talk explores some aspects of this phase shift at BNL's National Synchrotron Light Source.

  7. Round-robin 230Th– 234U age dating of bulk uranium for nuclear forensics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaffney, Amy M.; Hubert, Amélie; Kinman, William S.

    We report that in an inter-laboratory measurement comparison study, four laboratories determined 230Th– 234U model ages of uranium certified reference material NBL U050 using isotope dilution mass spectrometry. The model dates determined by the participating laboratories range from 9 March 1956 to 19 October 1957, and are indistinguishable given the associated measurement uncertainties. These model ages are concordant with to slightly older than the known production age of NBL U050.

  8. Stable isotope quality assurance using the 'calibrated IRMS' strategy.

    PubMed

    Meijer, Harro A J

    2009-06-01

    Procedures in our laboratory have always been directed towards complete understanding of all processes involved and corrections needed etc., instead of relying fully on laboratory reference materials. This rather principal strategy (or attitude) is probably not optimal in the economic sense, and is not necessarily more accurate either. Still, it has proven to be very rewarding in its capability to detect caveats that go undiscovered in the standard way of measurement, but that do influence the accuracy or reliability of the measurement procedure. An additional benefit of our laboratory procedures is that it makes us capable of assisting the International Atomic Energy Agency (IAEA) with primary questions like mutual scale assignments and comparison of isotope ratios of the same isotope in different matrices (like delta(18)O in water, carbonates and atmospheric CO(2)), establishment of the (17)O-(18)O relation, and the replenishment of the calibration standards. Finally, for manual preparation systems with a low sample throughput (and thus only few reference materials analysed) it may well be the only way to produce reliable results.

  9. The Astronomy Collections: From the Project to the Laboratory

    NASA Astrophysics Data System (ADS)

    Bobis, L.

    2015-04-01

    Within some astronomical libraries, just as it is with other libraries, there are collections we might refer to as being in "the border zone." The materials most representative of this are those that relate to an institution's heritage and history. The challenges of these patrimonial collections are scientific, legal, economic, and political. These collections establish the scientific status of their respective libraries because they extend beyond meeting the needs of astronomers: the material is important in defining the history of the field. The influence of these libraries derives from these heritage materials. From this point of view, the library is a worksite and a laboratory for librarians, project managers, and researchers.

  10. Application of the 226Ra– 230Th– 234U and 227Ac– 231Pa– 235U radiochronometers to uranium certified reference materials

    DOE PAGES

    Rolison, John M.; Treinen, Kerri C.; McHugh, Kelly C.; ...

    2017-11-06

    Uranium certified reference materials (CRM) issued by New Brunswick Laboratory were subjected to dating using four independent uranium-series radiochronometers. In all cases, there was acceptable agreement between the model ages calculated using the 231Pa– 235U, 230Th– 234U, 227Ac– 235U or 226Ra– 234U radiochronometers and either the certified 230Th– 234U model date (CRM 125-A and CRM U630), or the known purification date (CRM U050 and CRM U100). Finally, the agreement between the four independent radiochronometers establishes these uranium certified reference materials as ideal informal standards for validating dating techniques utilized in nuclear forensic investigations in the absence of standards with certifiedmore » model ages for multiple radiochronometers.« less

  11. Application of the 226Ra– 230Th– 234U and 227Ac– 231Pa– 235U radiochronometers to uranium certified reference materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rolison, John M.; Treinen, Kerri C.; McHugh, Kelly C.

    Uranium certified reference materials (CRM) issued by New Brunswick Laboratory were subjected to dating using four independent uranium-series radiochronometers. In all cases, there was acceptable agreement between the model ages calculated using the 231Pa– 235U, 230Th– 234U, 227Ac– 235U or 226Ra– 234U radiochronometers and either the certified 230Th– 234U model date (CRM 125-A and CRM U630), or the known purification date (CRM U050 and CRM U100). Finally, the agreement between the four independent radiochronometers establishes these uranium certified reference materials as ideal informal standards for validating dating techniques utilized in nuclear forensic investigations in the absence of standards with certifiedmore » model ages for multiple radiochronometers.« less

  12. Hydrogen and the materials of a sustainable energy future

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zalbowitz, M.

    1997-02-01

    The National Educator`s Workshop (NEW): Update 96 was held October 27--30, 1996, and was hosted by Los Alamos National Laboratory. This was the 11th annual conference aimed at improving the teaching of material science, engineering and technology by updating educators and providing laboratory experiments on emerging technology for teaching fundamental and newly evolving materials concepts. The Hydrogen Education Outreach Activity at Los Alamos National Laboratory organized a special conference theme: Hydrogen and the Materials of a Sustainable Energy Future. The hydrogen component of the NEW:Update 96 offered the opportunity for educators to have direct communication with scientists in laboratory settings,more » develop mentor relationship with laboratory staff, and bring leading edge materials/technologies into the classroom to upgrade educational curricula. Lack of public education and understanding about hydrogen is a major barrier for initial implementation of hydrogen energy technologies and is an important prerequisite for acceptance of hydrogen outside the scientific/technical research communities. The following materials contain the papers and view graphs from the conference presentations. In addition, supplemental reference articles are also included: a general overview of hydrogen and an article on handling hydrogen safely. A resource list containing a curriculum outline, bibliography, Internet resources, and a list of periodicals often publishing relevant research articles can be found in the last section.« less

  13. Mystery #1

    Atmospheric Science Data Center

    2013-04-22

    ... is approximately 380 kilometers wide. Choose any reference material you like and see if you can answer these questions: 1.   This ... NASA's Jet Propulsion Laboratory, Pasadena, CA, for NASA's Science Mission Directorate, Washington, D.C. The Terra spacecraft is managed ...

  14. Development of Advanced 9Cr Ferritic-Martensitic Steels and Austenitic Stainless Steels for Sodium-Cooled Fast Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sham, Sam; Tan, Lizhen; Yamamoto, Yukinori

    2013-01-01

    Ferritic-martensitic (FM) steel Grade 92, with or without thermomechanical treatment (TMT), and austenitic stainless steels HT-UPS (high-temperature ultrafine precipitate strengthening) and NF709 were selected as potential candidate structural materials in the U.S. Sodium-cooled Fast Reactor (SFR) program. The objective is to develop advanced steels with improved properties as compared with reference materials such as Grade 91 and Type 316H steels that are currently in nuclear design codes. Composition modification and/or processing optimization (e.g., TMT and cold-work) were performed to improve properties such as resistance to thermal aging, creep, creep-fatigue, fracture, and sodium corrosion. Testings to characterize these properties for themore » advanced steels were conducted by the Idaho National Laboratory, the Argonne National Laboratory and the Oak Ridge National Laboratory under the U.S. SFR program. This paper focuses on the resistance to thermal aging and creep of the advanced steels. The advanced steels exhibited up to two orders of magnitude increase in creep life compared to the reference materials. Preliminary results on the weldment performance of the advanced steels are also presented. The superior performance of the advanced steels would improve reactor design flexibility, safety margins and economics.« less

  15. TREAT Asia Quality Assessment Scheme (TAQAS) to standardize the outcome of HIV genotypic resistance testing in a group of Asian laboratories

    PubMed Central

    Land, Sally; Cunningham, Philip; Zhou, Jialun; Frost, Kevin; Katzenstein, David; Kantor, Rami; Chen, Yi-Ming Arthur; Oka, Shinichi; DeLong, Allison; Sayer, David; Smith, Jeffery; Dax, Elizabeth M.; Law, Matthew

    2010-01-01

    The TREAT Asia (Therapeutics, Research, Education, and AIDS Training in Asia) Network is building capacity for Human Immunodeficiency Virus Type-1 (HIV-1) drug resistance testing in the region. The objective of the TREAT Asia Quality Assessment Scheme – designated TAQAS – is to standardize HIV-1 genotypic resistance testing (HIV genotyping) among laboratories to permit rigorous comparison of results from different clinics and testing centres. TAQAS has evaluated three panels of HIV-1-positive plasma from clinical material or low-passage, culture supernatant for up to 10 Asian laboratories. Laboratory participants used their standard protocols to perform HIV genotyping. Assessment was in comparison to a target genotype derived from all participants and the reference laboratory’s result. Agreement between most participants at the edited nucleotide sequence level was high (>98%). Most participants performed to the reference laboratory standard in detection of drug resistance mutations (DRMs). However, there was variation in the detection of nucleotide mixtures (0–83%) and a significant correlation with the detection of DRMs (p < 0.01). Interpretation of antiretroviral resistance showed ~70% agreement among participants when different interpretation systems were used but >90% agreement with a common interpretation system, within the Stanford University Drug Resistance Database. Using the principles of external quality assessment and a reference laboratory, TAQAS has demonstrated high quality HIV genotyping results from Asian laboratories. PMID:19490972

  16. [Preparation and certification of mussel reference material for organochlorine pesticides and polychlorinated biphenyls using isotope dilution-high resolution mass spectrometry].

    PubMed

    Lu, Xianbo; Chen, Jiping; Wang, Shuqiu; Zou, Lili; Tian, Yuzeng; Ni, Yuwen; Su, Fan

    2012-09-01

    A method for the preparation and certification of the reference material of organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs) in mussel tissue is described. The mussel tissue from Dalian Bay was frozen-dried, comminuted, sieved, homogenized, packaged, and sterilized by 60Co radiation sterilization in turn. The certified values for 18 OCPs and 16 PCBs were determined by high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) using isotope dilution and internal standard quantitation techniques. The certified values were validated and given based on seven accredited laboratories, and these values are traceable to the SI (international system of units) through gravimetrically prepared standards of established purity and measurement intercomparisons. The certified values of PCBs and OCPs in mussel span 4 orders of magnitude with a relative uncertainty of about 10%. This material is a natural biological material with confirmed good homogeneity and stability, and it was approved as the grade "primary reference material" (GBW10069) in June 2012 in China. This reference material provided necessary quality control products for our country to implement the Stockholm Treaty on the monitoring of persistent organic pollutants (POPs). The material is intended to be used for the method validation and quality control in the determination of OCPs and PCBs in biota samples.

  17. Laboratory safety handbook

    USGS Publications Warehouse

    Skinner, E.L.; Watterson, C.A.; Chemerys, J.C.

    1983-01-01

    Safety, defined as 'freedom from danger, risk, or injury,' is difficult to achieve in a laboratory environment. Inherent dangers, associated with water analysis and research laboratories where hazardous samples, materials, and equipment are used, must be minimized to protect workers, buildings, and equipment. Managers, supervisors, analysts, and laboratory support personnel each have specific responsibilities to reduce hazards by maintaining a safe work environment. General rules of conduct and safety practices that involve personal protection, laboratory practices, chemical handling, compressed gases handling, use of equipment, and overall security must be practiced by everyone at all levels. Routine and extensive inspections of all laboratories must be made regularly by qualified people. Personnel should be trained thoroughly and repetitively. Special hazards that may involve exposure to carcinogens, cryogenics, or radiation must be given special attention, and specific rules and operational procedures must be established to deal with them. Safety data, reference materials, and texts must be kept available if prudent safety is to be practiced and accidents prevented or minimized.

  18. Setting maximum limits for trace elements in baby food in European legislation: the outcome of International Measurement Evaluation Programme®-33.

    PubMed

    Cordeiro, F; Baer, I; Robouch, P; Emteborg, H; Can, S Z; Krata, A; Zampella, M; Quétel, C R; Hearn, R; De la Calle, B

    2013-01-01

    The Institute for Reference Materials and Measurements (IRMM) of the Joint Research Centre (JRC), a Directorate-General of the European Commission, operates the International Measurement Evaluation Programme® (IMEP). It organises various types of inter-laboratory comparisons in support of European Union policies. This paper presents the results of a proficiency testing exercise (PT) focusing on the determination of total cadmium (Cd) and total lead (Pb) mass fractions in baby food in support to Commission Regulation (EC) 1881/2006 of 19 December 2006 setting maximum levels for certain contaminants in foodstuffs. The test material used in this exercise was soya-based baby food formula purchased in a local pharmacy and prepared by the Reference Materials Unit of the IRMM for this exercise. Sixty-six laboratories from 23 countries registered to the exercise and 61 of them reported results. Each participant received one bottle containing approximately 15 g of test material. Participants were asked to quantify the measurands in the powder and in the reconstituted formula. Reference values independent from the participants' results were established using isotope dilution inductively coupled plasma mass spectrometry. The total Cd mass fraction was determined by IRMM and LGC Ltd (UK), while the total Pb was determined by IRMM. The standard deviation for proficiency assessment σ^ was set at 22% of the assigned value for all measurands. Laboratories were rated with z- and ζ- (zeta) scores in accordance with ISO 13528. The outcome of this exercise is clearly influenced by the very low level of Cd and Pb content in the test material which triggered: a high number of 'less than' values; overestimated values especially for Pb very likely due to contamination; and a visible method influence in the case of Pb (methods based on atomic absorption were not sensitive enough to attain such low limits of detection). The results were also evaluated with regard to the reported limit of detection and some incoherencies were observed.

  19. Use of diagnostic accuracy as a metric for evaluating laboratory proficiency with microarray assays using mixed-tissue RNA reference samples.

    PubMed

    Pine, P S; Boedigheimer, M; Rosenzweig, B A; Turpaz, Y; He, Y D; Delenstarr, G; Ganter, B; Jarnagin, K; Jones, W D; Reid, L H; Thompson, K L

    2008-11-01

    Effective use of microarray technology in clinical and regulatory settings is contingent on the adoption of standard methods for assessing performance. The MicroArray Quality Control project evaluated the repeatability and comparability of microarray data on the major commercial platforms and laid the groundwork for the application of microarray technology to regulatory assessments. However, methods for assessing performance that are commonly applied to diagnostic assays used in laboratory medicine remain to be developed for microarray assays. A reference system for microarray performance evaluation and process improvement was developed that includes reference samples, metrics and reference datasets. The reference material is composed of two mixes of four different rat tissue RNAs that allow defined target ratios to be assayed using a set of tissue-selective analytes that are distributed along the dynamic range of measurement. The diagnostic accuracy of detected changes in expression ratios, measured as the area under the curve from receiver operating characteristic plots, provides a single commutable value for comparing assay specificity and sensitivity. The utility of this system for assessing overall performance was evaluated for relevant applications like multi-laboratory proficiency testing programs and single-laboratory process drift monitoring. The diagnostic accuracy of detection of a 1.5-fold change in signal level was found to be a sensitive metric for comparing overall performance. This test approaches the technical limit for reliable discrimination of differences between two samples using this technology. We describe a reference system that provides a mechanism for internal and external assessment of laboratory proficiency with microarray technology and is translatable to performance assessments on other whole-genome expression arrays used for basic and clinical research.

  20. ASVCP quality assurance guidelines: external quality assessment and comparative testing for reference and in-clinic laboratories.

    PubMed

    Camus, Melinda S; Flatland, Bente; Freeman, Kathleen P; Cruz Cardona, Janice A

    2015-12-01

    The purpose of this document is to educate providers of veterinary laboratory diagnostic testing in any setting about comparative testing. These guidelines will define, explain, and illustrate the importance of a multi-faceted laboratory quality management program which includes comparative testing. The guidelines will provide suggestions for implementation of such testing, including which samples should be tested, frequency of testing, and recommendations for result interpretation. Examples and a list of vendors and manufacturers supplying control materials and services to veterinary laboratories are also included. © 2015 American Society for Veterinary Clinical Pathology.

  1. Variability of bioaccessibility results using seventeen different methods on a standard reference material, NIST 2710.

    PubMed

    Koch, Iris; Reimer, Kenneth J; Bakker, Martine I; Basta, Nicholas T; Cave, Mark R; Denys, Sébastien; Dodd, Matt; Hale, Beverly A; Irwin, Rob; Lowney, Yvette W; Moore, Margo M; Paquin, Viviane; Rasmussen, Pat E; Repaso-Subang, Theresa; Stephenson, Gladys L; Siciliano, Steven D; Wragg, Joanna; Zagury, Gerald J

    2013-01-01

    Bioaccessibility is a measurement of a substance's solubility in the human gastro-intestinal system, and is often used in the risk assessment of soils. The present study was designed to determine the variability among laboratories using different methods to measure the bioaccessibility of 24 inorganic contaminants in one standardized soil sample, the standard reference material NIST 2710. Fourteen laboratories used a total of 17 bioaccessibility extraction methods. The variability between methods was assessed by calculating the reproducibility relative standard deviations (RSDs), where reproducibility is the sum of within-laboratory and between-laboratory variability. Whereas within-laboratory repeatability was usually better than (<) 15% for most elements, reproducibility RSDs were much higher, indicating more variability, although for many elements they were comparable to typical uncertainties (e.g., 30% in commercial laboratories). For five trace elements of interest, reproducibility RSDs were: arsenic (As), 22-44%; cadmium (Cd), 11-41%; Cu, 15-30%; lead (Pb), 45-83%; and Zn, 18-56%. Only one method variable, pH, was found to correlate significantly with bioaccessibility for aluminum (Al), Cd, copper (Cu), manganese (Mn), Pb and zinc (Zn) but other method variables could not be examined systematically because of the study design. When bioaccessibility results were directly compared with bioavailability results for As (swine and mouse) and Pb (swine), four methods returned results within uncertainty ranges for both elements: two that were defined as simpler (gastric phase only, limited chemicals) and two were more complex (gastric + intestinal phases, with a mixture of chemicals).

  2. Second NBL measurement evaluation program meeting: A summary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spaletto, M.I.; Clapper, M.; Tolbert, M.E.M.

    New Brunswick Laboratory (NBL), the US government`s nuclear materials measurements and reference materials laboratory, administers interlaboratory measurement evaluation programs to evaluate the quality and adequacy of safeguards measurements. The NBL Measurement Evaluation Program covers several types of safeguards analytical measurements. The Safeguards Measurement Evaluation (SME) program distributes test materials destructive measurements of uranium for both elemental concentration and isotopic abundances, and of plutonium for isotopic abundances. The Calorimetry Exchange (CalEx) Program tests the quality of nondestructive measurements of plutonium isotopic abundances by gamma spectroscopy and plutonium concentration by calorimetry. In May 1997, more than 30 representatives from the Department ofmore » Energy (DOE), its contractor laboratories, and Nuclear Regulatory Commission licensees met at NBL in Argonne, Illinois, for the annual meeting of the Measurement Evaluation Program. The summary which follows details key points that were discussed or presented at the meeting.« less

  3. Comprehensive inter-laboratory calibration of reference materials for δ18O versus VSMOW using various on-line high-temperature conversion techniques

    USGS Publications Warehouse

    Brand, Willi A.; Coplen, Tyler B.; Aerts-Bijma, Anita T.; Bohlke, John Karl; Gehre, Matthias; Geilmann, Heike; Groning, Manfred; Jansen, Henk G.; Meijer, Harro A. J.; Mroczkowski, Stanley J.; Qi, Haiping; Soergel, Karin; Stuart-Williams, Hilary; Weise, Stephan M.; Werner, Roland A.

    2009-01-01

    Internationally distributed organic and inorganic oxygen isotopic reference materials have been calibrated by six laboratories carrying out more than 5300 measurements using a variety of high-temperature conversion techniques (HTC) in an evaluation sponsored by the International Union of Pure and Applied Chemistry (IUPAC). To aid in the calibration of these reference materials, which span more than 125‰, an artificially enriched reference water (δ18O of +78.91‰) and two barium sulfates (one depleted and one enriched in 18O) were prepared and calibrated relative to VSMOW2 and SLAP reference waters. These materials were used to calibrate the other isotopic reference materials in this study, which yielded:Reference materialδ18O and estimated combined uncertainty IAEA-602 benzoic acid+71.28 ± 0.36‰USGS35 sodium nitrate+56.81 ± 0.31‰IAEA-NO-3 potassium nitrate+25.32 ± 0.29‰IAEA-601 benzoic acid+23.14 ± 0.19‰IAEA-SO-5 barium sulfate+12.13 ± 0.33‰NBS 127 barium sulfate+8.59 ± 0.26‰VSMOW2 water0‰IAEA-600 caffeine−3.48 ± 0.53‰IAEA-SO-6 barium sulfate−11.35 ± 0.31‰USGS34 potassium nitrate−27.78 ± 0.37‰SLAP water−55.5‰The seemingly large estimated combined uncertainties arise from differences in instrumentation and methodology and difficulty in accounting for all measurement bias. They are composed of the 3-fold standard errors directly calculated from the measurements and provision for systematic errors discussed in this paper. A primary conclusion of this study is that nitrate samples analyzed for δ18O should be analyzed with internationally distributed isotopic nitrates, and likewise for sulfates and organics. Authors reporting relative differences of oxygen-isotope ratios (δ18O) of nitrates, sulfates, or organic material should explicitly state in their reports the δ18O values of two or more internationally distributed nitrates (USGS34, IAEA-NO-3, and USGS35), sulfates (IAEA-SO-5, IAEA-SO-6, and NBS 127), or organic material (IAEA-601 benzoic acid, IAEA-602 benzoic acid, and IAEA-600 caffeine), as appropriate to the material being analyzed, had these reference materials been analyzed with unknowns. This procedure ensures that readers will be able to normalize the δ18O values at a later time should it become necessary.The high-temperature reduction technique for analyzing δ18O and δ2H is not as widely applicable as the well-established combustion technique for carbon and nitrogen stable isotope determination. To obtain the most reliable stable isotope data, materials should be treated in an identical fashion; within the same sequence of analyses, samples should be compared with working reference materials that are as similar in nature and in isotopic composition as feasible.

  4. 46 CFR 162.060-5 - Incorporation by reference.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Ballast Water Management Systems § 162.060-5 Incorporation by...), Environmental Technology Verification Program, National Risk Management Research Laboratory Office of Research...

  5. Plying Your Craft: Instructional Development and the Use of Heuristics.

    ERIC Educational Resources Information Center

    Noel, Kent L.; Hewlett, Brent

    1981-01-01

    Examines an instructional systems design (ISD) model used by Bell Laboratories as an illustration of how heuristics can be brought to bear upon the design and development of instructional materials. Ten references are listed. (Author/MER)

  6. Scintillator handbook with emphasis on cesium iodide

    NASA Technical Reports Server (NTRS)

    Tidd, J. L.; Dabbs, J. R.; Levine, N.

    1973-01-01

    This report provides a background of reasonable depth and reference material on scintillators in general. Particular attention is paid to the cesium iodide scintillators as used in the High Energy Astronomy Observatory (HEAO) experiments. It is intended especially for use by persons such as laboratory test personnel who need to obtain a working knowledge of these materials and their characteristics in a short time.

  7. The National Ballistics Imaging Comparison (NBIC) project.

    PubMed

    Song, J; Vorburger, T V; Ballou, S; Thompson, R M; Yen, J; Renegar, T B; Zheng, A; Silver, R M; Ols, M

    2012-03-10

    In response to the guidelines issued by the American Society of Crime Laboratory Directors/Laboratory Accreditation Board (ASCLD/LAB-International) to establish traceability and quality assurance in U.S. crime laboratories, a NIST/ATF joint project entitled National Ballistics Imaging Comparison (NBIC) was initialized in 2008. The NBIC project aims to establish a National Traceability and Quality System for ballistics identifications in crime laboratories within the National Integrated Ballistics Information Network (NIBIN) of the U.S. NIST Standard Reference Material (SRM) 2460 bullets and 2461 cartridge cases are used as reference standards. 19 ballistics examiners from 13 U.S. crime laboratories participated in this project. They each performed 24 periodic image acquisitions and correlations of the SRM bullets and cartridge cases over the course of a year, but one examiner only participated in Phase 1 tests of SRM cartridge case. The correlation scores were collected by NIST for statistical analyses, from which control charts and control limits were developed for the proposed Quality System and for promoting future assessments and accreditations for firearm evidence in U.S. forensic laboratories in accordance with the ISO 17025 Standard. Published by Elsevier Ireland Ltd.

  8. Inter-laboratory analysis of selected genetically modified plant reference materials with digital PCR.

    PubMed

    Dobnik, David; Demšar, Tina; Huber, Ingrid; Gerdes, Lars; Broeders, Sylvia; Roosens, Nancy; Debode, Frederic; Berben, Gilbert; Žel, Jana

    2018-01-01

    Digital PCR (dPCR), as a new technology in the field of genetically modified (GM) organism (GMO) testing, enables determination of absolute target copy numbers. The purpose of our study was to test the transferability of methods designed for quantitative PCR (qPCR) to dPCR and to carry out an inter-laboratory comparison of the performance of two different dPCR platforms when determining the absolute GM copy numbers and GM copy number ratio in reference materials certified for GM content in mass fraction. Overall results in terms of measured GM% were within acceptable variation limits for both tested dPCR systems. However, the determined absolute copy numbers for individual genes or events showed higher variability between laboratories in one third of the cases, most possibly due to variability in the technical work, droplet size variability, and analysis of the raw data. GMO quantification with dPCR and qPCR was comparable. As methods originally designed for qPCR performed well in dPCR systems, already validated qPCR assays can most generally be used for dPCR technology with the purpose of GMO detection. Graphical abstract The output of three different PCR-based platforms was assessed in an inter-laboratory comparison.

  9. Toward Worldwide Hepcidin Assay Harmonization: Identification of a Commutable Secondary Reference Material.

    PubMed

    van der Vorm, Lisa N; Hendriks, Jan C M; Laarakkers, Coby M; Klaver, Siem; Armitage, Andrew E; Bamberg, Alison; Geurts-Moespot, Anneke J; Girelli, Domenico; Herkert, Matthias; Itkonen, Outi; Konrad, Robert J; Tomosugi, Naohisa; Westerman, Mark; Bansal, Sukhvinder S; Campostrini, Natascia; Drakesmith, Hal; Fillet, Marianne; Olbina, Gordana; Pasricha, Sant-Rayn; Pitts, Kelly R; Sloan, John H; Tagliaro, Franco; Weykamp, Cas W; Swinkels, Dorine W

    2016-07-01

    Absolute plasma hepcidin concentrations measured by various procedures differ substantially, complicating interpretation of results and rendering reference intervals method dependent. We investigated the degree of equivalence achievable by harmonization and the identification of a commutable secondary reference material to accomplish this goal. We applied technical procedures to achieve harmonization developed by the Consortium for Harmonization of Clinical Laboratory Results. Eleven plasma hepcidin measurement procedures (5 mass spectrometry based and 6 immunochemical based) quantified native individual plasma samples (n = 32) and native plasma pools (n = 8) to assess analytical performance and current and achievable equivalence. In addition, 8 types of candidate reference materials (3 concentrations each, n = 24) were assessed for their suitability, most notably in terms of commutability, to serve as secondary reference material. Absolute hepcidin values and reproducibility (intrameasurement procedure CVs 2.9%-8.7%) differed substantially between measurement procedures, but all were linear and correlated well. The current equivalence (intermeasurement procedure CV 28.6%) between the methods was mainly attributable to differences in calibration and could thus be improved by harmonization with a common calibrator. Linear regression analysis and standardized residuals showed that a candidate reference material consisting of native lyophilized plasma with cryolyoprotectant was commutable for all measurement procedures. Mathematically simulated harmonization with this calibrator resulted in a maximum achievable equivalence of 7.7%. The secondary reference material identified in this study has the potential to substantially improve equivalence between hepcidin measurement procedures and contributes to the establishment of a traceability chain that will ultimately allow standardization of hepcidin measurement results. © 2016 American Association for Clinical Chemistry.

  10. Rapid Radiochemical Methods for Asphalt Paving Material ...

    EPA Pesticide Factsheets

    Technical Brief Validated rapid radiochemical methods for alpha and beta emitters in solid matrices that are commonly encountered in urban environments were previously unavailable for public use by responding laboratories. A lack of tested rapid methods would delay the quick determination of contamination levels and the assessment of acceptable site-specific exposure levels. Of special concern are matrices with rough and porous surfaces, which allow the movement of radioactive material deep into the building material making it difficult to detect. This research focuses on methods that address preparation, radiochemical separation, and analysis of asphalt paving materials and asphalt roofing shingles. These matrices, common to outdoor environments, challenge the capability and capacity of very experienced radiochemistry laboratories. Generally, routine sample preparation and dissolution techniques produce liquid samples (representative of the original sample material) that can be processed using available radiochemical methods. The asphalt materials are especially difficult because they do not readily lend themselves to these routine sample preparation and dissolution techniques. The HSRP and ORIA coordinate radiological reference laboratory priorities and activities in conjunction with HSRP’s Partner Process. As part of the collaboration, the HSRP worked with ORIA to publish rapid radioanalytical methods for selected radionuclides in building material matrice

  11. 40 CFR Appendix A-1 to Part 50 - Reference Measurement Principle and Calibration Procedure for the Measurement of Sulfur Dioxide...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... to conveniently divert the SO2 from the sampling manifold to provide clean zero air at the output manifold for zero adjustment. The system may be made up using common laboratory components, or it may be a... Reference Material (SRM). 4.1.6.2Clean zero air, free of contaminants that could cause a detectable response...

  12. 40 CFR Appendix A-1 to Part 50 - Reference Measurement Principle and Calibration Procedure for the Measurement of Sulfur Dioxide...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... to conveniently divert the SO2 from the sampling manifold to provide clean zero air at the output manifold for zero adjustment. The system may be made up using common laboratory components, or it may be a... Reference Material (SRM). 4.1.6.2Clean zero air, free of contaminants that could cause a detectable response...

  13. 40 CFR Appendix A-1 to Part 50 - Reference Measurement Principle and Calibration Procedure for the Measurement of Sulfur Dioxide...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... to conveniently divert the SO2 from the sampling manifold to provide clean zero air at the output manifold for zero adjustment. The system may be made up using common laboratory components, or it may be a... Reference Material (SRM). 4.1.6.2Clean zero air, free of contaminants that could cause a detectable response...

  14. 40 CFR Appendix A-1 to Part 50 - Reference Measurement Principle and Calibration Procedure for the Measurement of Sulfur Dioxide...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... to conveniently divert the SO2 from the sampling manifold to provide clean zero air at the output manifold for zero adjustment. The system may be made up using common laboratory components, or it may be a... Reference Material (SRM). 4.1.6.2Clean zero air, free of contaminants that could cause a detectable response...

  15. ANALYSIS OF ESSENTIAL NUCLEAR REACTOR MATERIALS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rodden, C.J.

    1964-01-01

    This book is intended as a laboratory reference tool. The separate book chapters have been written by workers in the various fields covered, with a couple written by the contributing editor, Clement J. Rodden. The chapters were abstracted separately for the database.

  16. Standardization of gamma-glutamyltransferase assays by intermethod calibration. Effect on determining common reference limits.

    PubMed

    Steinmetz, Josiane; Schiele, Françoise; Gueguen, René; Férard, Georges; Henny, Joseph

    2007-01-01

    The improvement of the consistency of gamma-glutamyltransferase (GGT) activity results among different assays after calibration with a common material was estimated. We evaluated if this harmonization could lead to reference limits common to different routine methods. Seven laboratories measured GGT activity using their own routine analytical system both according to the manufacturer's recommendation and after calibration with a multi-enzyme calibrator [value assigned by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) reference procedure]. All samples were re-measured using the IFCC reference procedure. Two groups of subjects were selected in each laboratory: a group of healthy men aged 18-25 years without long-term medication and with alcohol consumption less than 44 g/day and a group of subjects with elevated GGT activity. The day-to-day coefficients of variation were less than 2.9% in each laboratory. The means obtained in the group of healthy subjects without common calibration (range of the means 16-23 U/L) were significantly different from those obtained by the IFCC procedure in five laboratories. After calibration, the means remained significantly different from the IFCC procedure results in only one laboratory. For three calibrated methods, the slope values of linear regression vs. the IFCC procedure were not different from the value 1. The results obtained with these three methods for healthy subjects (n=117) were gathered and reference limits were calculated. These were 11-49 U/L (2.5th-97.5th percentiles). The calibration also improved the consistency of elevated results when compared to the IFCC procedure. The common calibration improved the level of consistency between different routine methods. It permitted to define common reference limits which are quite similar to those proposed by the IFCC. This approach should lead to a real benefit in terms of prevention, screening, diagnosis, therapeutic monitoring and for epidemiological studies.

  17. A new marine sediment certified reference material (CRM) for the determination of persistent organic contaminants: IAEA-459.

    PubMed

    Tolosa, Imma; Cassi, Roberto; Huertas, David

    2018-04-11

    A new marine sediment certified reference material (IAEA 459) with very low concentrations (μg kg -1 ) for a variety of persistent organic contaminants (POPs) listed by the Stockholm Convention, as well as other POPs and priority substances (PSs) listed in many environmental monitoring programs was developed by the IAEA. The sediment material was collected from the Ham River estuary in South Korea, and the assigned final values were derived from robust statistics on the results provided by selected laboratories which demonstrated technical and quality competence, following the guidance given in ISO Guide 35. The robust mean of the laboratory means was assigned as certified values, for those compounds where the assigned value was derived from at least five datasets and its relative expanded uncertainty was less than 40% of the assigned value (most of the values ranging from 8 to 20%). All the datasets were derived from at least two different analytical techniques which have allowed the assignment of certified concentrations for 22 polychlorinated biphenyl (PCB) congeners, 6 organochlorinated (OC) pesticides, 5 polybrominated diphenyl ethers (PBDEs), and 18 polycyclic aromatic hydrocarbon (PAHs). Mass fractions of compounds that did not fulfill the criteria of certification are considered information values, which include 29 PAHs, 11 PCBs, 16 OC pesticides, and 5 PBDEs. The extensive characterization and associated uncertainties at concentration levels close to the marine sediment quality guidelines will make CRM 459 a valuable matrix reference material for use in marine environmental monitoring programs.

  18. The Geochemical Databases GEOROC and GeoReM - What's New?

    NASA Astrophysics Data System (ADS)

    Sarbas, B.; Jochum, K. P.; Nohl, U.; Weis, U.

    2017-12-01

    The geochemical databases GEOROC (http: georoc.mpch-mainz.gwdg.de) and GeoReM (http: georem.mpch-mainz.gwdg.de) are maintained by the Max Planck Institute for Chemistry in Mainz, Germany. Both online databases became crucial tools for geoscientists from different research areas. They are regularly upgraded by new tools and new data from recent publications obtained from a wide range of international journals. GEOROC is a collection of published analyses of volcanic rocks and mantle xenoliths. Since recently, data for plutonic rocks are added. The analyses include major and trace element concentrations, radiogenic and non-radiogenic isotope ratios as well as analytical ages for whole rocks, glasses, minerals and inclusions. Samples come from eleven geological settings and span the whole geological age scale from Archean to Recent. Metadata include, among others, geographic location, rock class and rock type, geological age, degree of alteration, analytical method, laboratory, and reference. The GEOROC web page allows selection of samples by geological setting, geography, chemical criteria, rock or sample name, and bibliographic criteria. In addition, it provides a large number of precompiled files for individual locations, minerals and rock classes. GeoReM is a database collecting information about reference materials of geological and environmental interest, such as rock powders, synthetic and natural glasses as well as mineral, isotopic, biological, river water and seawater reference materials. It contains published data and compilation values (major and trace element concentrations and mass fractions, radiogenic and stable isotope ratios). Metadata comprise, among others, uncertainty, analytical method and laboratory. Reference materials are important for calibration, method validation, quality control and to establish metrological traceability. GeoReM offers six different search strategies: samples or materials (published values), samples (GeoReM preferred values), chemical criteria, chemical criteria based on bibliography, bibliography, as well as methods and institutions.

  19. Identification of TL-Om1, an Adult T-Cell Leukemia (ATL) Cell Line, as Reference Material for Quantitative PCR for Human T-Lymphotropic Virus 1

    PubMed Central

    Okuma, Kazu; Yamagishi, Makoto; Yamochi, Tadanori; Firouzi, Sanaz; Momose, Haruka; Mizukami, Takuo; Takizawa, Kazuya; Araki, Kumiko; Sugamura, Kazuo; Yamaguchi, Kazunari; Watanabe, Toshiki

    2014-01-01

    Quantitative PCR (qPCR) for human T-lymphotropic virus 1 (HTLV-1) is useful for measuring the amount of integrated HTLV-1 proviral DNA in peripheral blood mononuclear cells. Many laboratories in Japan have developed different HTLV-1 qPCR methods. However, when six independent laboratories analyzed the proviral load of the same samples, there was a 5-fold difference in their results. To standardize HTLV-1 qPCR, preparation of a well-defined reference material is needed. We analyzed the integrated HTLV-1 genome and the internal control (IC) genes of TL-Om1, a cell line derived from adult T-cell leukemia, to confirm its suitability as a reference material for HTLV-1 qPCR. Fluorescent in situ hybridization (FISH) showed that HTLV-1 provirus was monoclonally integrated in chromosome 1 at the site of 1p13 in the TL-Om1 genome. HTLV-1 proviral genome was not transferred from TL-Om1 to an uninfected T-cell line, suggesting that the HTLV-1 proviral copy number in TL-Om1 cells is stable. To determine the copy number of HTLV-1 provirus and IC genes in TL-Om1 cells, we used FISH, digital PCR, and qPCR. HTLV-1 copy numbers obtained by these three methods were similar, suggesting that their results were accurate. Also, the ratio of the copy number of HTLV-1 provirus to one of the IC genes, RNase P, was consistent for all three methods. These findings indicate that TL-Om1 cells are an appropriate reference material for HTLV-1 qPCR. PMID:25502533

  20. Empirical insights and considerations for the OBT inter-laboratory comparison of environmental samples.

    PubMed

    Kim, Sang-Bog; Roche, Jennifer

    2013-08-01

    Organically bound tritium (OBT) is an important tritium species that can be measured in most environmental samples, but has only recently been recognized as a species of tritium in these samples. Currently, OBT is not routinely measured by environmental monitoring laboratories around the world. There are no certified reference materials (CRMs) for environmental samples. Thus, quality assurance (QA), or verification of the accuracy of the OBT measurement, is not possible. Alternatively, quality control (QC), or verification of the precision of the OBT measurement, can be achieved. In the past, there have been differences in OBT analysis results between environmental laboratories. A possible reason for the discrepancies may be differences in analytical methods. Therefore, inter-laboratory OBT comparisons among the environmental laboratories are important and would provide a good opportunity for adopting a reference OBT analytical procedure. Due to the analytical issues, only limited information is available on OBT measurement. Previously conducted OBT inter-laboratory practices are reviewed and the findings are described. Based on our experiences, a few considerations were suggested for the international OBT inter-laboratory comparison exercise to be completed in the near future. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  1. Characterization of 137 Genomic DNA Reference Materials for 28 Pharmacogenetic Genes: A GeT-RM Collaborative Project.

    PubMed

    Pratt, Victoria M; Everts, Robin E; Aggarwal, Praful; Beyer, Brittany N; Broeckel, Ulrich; Epstein-Baak, Ruth; Hujsak, Paul; Kornreich, Ruth; Liao, Jun; Lorier, Rachel; Scott, Stuart A; Smith, Chingying Huang; Toji, Lorraine H; Turner, Amy; Kalman, Lisa V

    2016-01-01

    Pharmacogenetic testing is increasingly available from clinical laboratories. However, only a limited number of quality control and other reference materials are currently available to support clinical testing. To address this need, the Centers for Disease Control and Prevention-based Genetic Testing Reference Material Coordination Program, in collaboration with members of the pharmacogenetic testing community and the Coriell Cell Repositories, has characterized 137 genomic DNA samples for 28 genes commonly genotyped by pharmacogenetic testing assays (CYP1A1, CYP1A2, CYP2A6, CYP2B6, CYP2C8, CYP2C9, CYP2C19, CYP2D6, CYP2E1, CYP3A4, CYP3A5, CYP4F2, DPYD, GSTM1, GSTP1, GSTT1, NAT1, NAT2, SLC15A2, SLC22A2, SLCO1B1, SLCO2B1, TPMT, UGT1A1, UGT2B7, UGT2B15, UGT2B17, and VKORC1). One hundred thirty-seven Coriell cell lines were selected based on ethnic diversity and partial genotype characterization from earlier testing. DNA samples were coded and distributed to volunteer testing laboratories for targeted genotyping using a number of commercially available and laboratory developed tests. Through consensus verification, we confirmed the presence of at least 108 variant pharmacogenetic alleles. These samples are also being characterized by other pharmacogenetic assays, including next-generation sequencing, which will be reported separately. Genotyping results were consistent among laboratories, with most differences in allele assignments attributed to assay design and variability in reported allele nomenclature, particularly for CYP2D6, UGT1A1, and VKORC1. These publicly available samples will help ensure the accuracy of pharmacogenetic testing. Copyright © 2016 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  2. Quantification of Cells with Specific Phenotypes I: Determination of CD4+ Cell Count Per Microliter in Reconstituted Lyophilized Human PBMC Prelabeled with Anti-CD4 FITC Antibody

    PubMed Central

    Stebbings, Richard; Wang, Lili; Sutherland, Janet; Kammel, Martin; Gaigalas, Adolfas K; John, Manuela; Roemer, Bodo; Kuhne, Maren; Schneider, Rudolf J; Braun, Michael; Engel, Andrea; Dikshit, Dinesh K; Abbasi, Fatima; Marti, Gerald E; Paola Sassi, Maria; Revel, Laura; Kim, Sook-Kyung; Baradez, Marc-Olivier; Lekishvili, Tamara; Marshall, Damian; Whitby, Liam; Jing, Wang; Ost, Volker; Vonsky, Maxim; Neukammer, Jörg

    2015-01-01

    A surface-labeled lyophilized lymphocyte (sLL) preparation has been developed using human peripheral blood mononuclear cells prelabeled with a fluorescein isothiocyanate conjugated anti-CD4 monoclonal antibody. The sLL preparation is intended to be used as a reference material for CD4+ cell counting including the development of higher order reference measurement procedures and has been evaluated in the pilot study CCQM-P102. This study was conducted across 16 laboratories from eight countries to assess the ability of participants to quantify the CD4+ cell count of this reference material and to document cross-laboratory variability plus associated measurement uncertainties. Twelve different flow cytometer platforms were evaluated using a standard protocol that included calibration beads used to obtain quantitative measurements of CD4+ T cell counts. There was good overall cross-platform and counting method agreement with a grand mean of the laboratory calculated means of (301.7 ± 4.9) μL−1 CD4+ cells. Excluding outliers, greater than 90% of participant data agreed within ±15%. A major contribution to variation of sLL CD4+ cell counts was tube to tube variation of the calibration beads, amounting to an uncertainty of 3.6%. Variation due to preparative steps equated to an uncertainty of 2.6%. There was no reduction in variability when data files were centrally reanalyzed. Remaining variation was attributed to instrument specific differences. CD4+ cell counts obtained in CCQM-P102 are in excellent agreement and show the robustness of both the measurements and the data analysis and hence the suitability of sLL as a reference material for interlaboratory comparisons and external quality assessment. © 2015 The Authors. Published by Wiley Periodicals, Inc. PMID:25655255

  3. High frequency reference electrode

    DOEpatents

    Kronberg, J.W.

    1994-05-31

    A high frequency reference electrode for electrochemical experiments comprises a mercury-calomel or silver-silver chloride reference electrode with a layer of platinum around it and a layer of a chemically and electrically resistant material such as TEFLON around the platinum covering all but a small ring or halo' at the tip of the reference electrode, adjacent to the active portion of the reference electrode. The voltage output of the platinum layer, which serves as a redox electrode, and that of the reference electrode are coupled by a capacitor or a set of capacitors and the coupled output transmitted to a standard laboratory potentiostat. The platinum may be applied by thermal decomposition to the surface of the reference electrode. The electrode provides superior high-frequency response over conventional electrodes. 4 figs.

  4. High frequency reference electrode

    DOEpatents

    Kronberg, James W.

    1994-01-01

    A high frequency reference electrode for electrochemical experiments comprises a mercury-calomel or silver-silver chloride reference electrode with a layer of platinum around it and a layer of a chemically and electrically resistant material such as TEFLON around the platinum covering all but a small ring or "halo" at the tip of the reference electrode, adjacent to the active portion of the reference electrode. The voltage output of the platinum layer, which serves as a redox electrode, and that of the reference electrode are coupled by a capacitor or a set of capacitors and the coupled output transmitted to a standard laboratory potentiostat. The platinum may be applied by thermal decomposition to the surface of the reference electrode. The electrode provides superior high-frequency response over conventional electrodes.

  5. Intercomparison of CO 2 measurements

    NASA Astrophysics Data System (ADS)

    Poisson, A.; Culkin, F.; Ridout, P.

    1990-10-01

    Seawater samples, of four different salinities, were analysed for total alkalinity, total CO 2, pH and pCO 2 by up to 12 laboratories. The results showthat although most laboratories are capable of high precision in these determinations, there is an unacceptably high disagreement between their analyses of the same samples. For global programmes involving studies of the CO 2 system in seawater, it is strongly recommended that standard reference materials be made widely available.

  6. Procedure for contact electrical resistance measurements as developed for use at Sandia National Laboratories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Finch, J.L.

    1994-06-01

    Military Specifications call out general procedures and guidelines for conducting contact resistance measurements on chemical conversion coated panels. This paper deals with a test procedure developed at Sandia National Laboratories used to conduct contact electrical resistance on non-chromated conversion coated test panels. MIL-C-81706 {open_quotes}Chemical Conversion Materials For Coating Aluminum and Aluminum Alloys{close_quotes} was the reference specification used for guidance.

  7. Three Microstructural Exercises for Students.

    ERIC Educational Resources Information Center

    Means, Winthrop D.

    1986-01-01

    Describes laboratory exercises which demonstrate a new simplified technique for deforming thin samples of crystalline materials on the stage of a petrographic microscope. Discusses how this process allows students to see the development of microstructures resulting from cracking, slipping, thinning, and recrystallization. References and sources of…

  8. Analysis of Rail Gun Bore Residue

    DTIC Science & Technology

    1984-03-01

    erosion effects and elemental analysis of refractory materials. C. A. L. Westerdahl , J. Pinto, G. L. Ferventino, D. N. Saherhavth...accelerator facility at Large Caliber Weapons Systems Laboratory Dover, New Jersey. ’ 16 REFERENCES 1. C.A.L. Westerdahl , J. Pinto, G. L. Ferrentino, D

  9. Measurements for certification of chlortetracycline reference materials within the European Union Standards, Measurements and Testing programme.

    PubMed

    Juhel-Gaugain, M; McEvoy, J D; VanGinkel, L A

    2000-12-01

    The experimental design of a material certification programme is described. The matrix reference materials (RMs) comprised chlortetracycline (CTC)-containing and CTC-free lyophilised porcine liver, kidney and muscle produced under the European Commission's Standards Measurements and Testing (SMT) programme. The aim of the certification programme was to determine accurately and precisely the concentration of CTC and 4-epi-chlortetracycline (epi-CTC) contained in the RMs. A multi-laboratory approach was used to certify analyte concentrations. Participants (n = 19) were instructed to strictly adhere to previously established guidelines. Following the examination of analytical performance criteria, statistical manipulation of results submitted by 13 laboratories, (6 withdrew) allowed an estimate to be made of the true value of the analyte content. The Nalimov test was used for detection of outlying results. The Cochran and Bartlett tests were employed for testing the homogeneity of variances. The normality of results distribution was tested according to the Kolmogorov-Smirnov-Lilliefors test. One-way analysis of variance (ANOVA) was employed to calculate the within and between-laboratory standard deviations, the overall mean and confidence interval for the CTC and epi-CTC content of each of the RMs. Certified values were within or very close to the target concentration ranges specified in the SMT contract. These studies have demonstrated the successful production and certification of CTC-containing and CTC-free porcine RMs.

  10. Determination of the purity of pharmaceutical reference materials by 1H NMR using the standardless PULCON methodology.

    PubMed

    Monakhova, Yulia B; Kohl-Himmelseher, Matthias; Kuballa, Thomas; Lachenmeier, Dirk W

    2014-11-01

    A fast and reliable nuclear magnetic resonance spectroscopic method for quantitative determination (qNMR) of targeted molecules in reference materials has been established using the ERETIC2 methodology (electronic reference to access in vivo concentrations) based on the PULCON principle (pulse length based concentration determination). The developed approach was validated for the analysis of pharmaceutical samples in the context of official medicines control, including ibandronic acid, amantadine, ambroxol and lercanidipine. The PULCON recoveries were above 94.3% and coefficients of variation (CVs) obtained by quantification of different targeted resonances ranged between 0.7% and 2.8%, demonstrating that the qNMR method is a precise tool for rapid quantification (approximately 15min) of reference materials and medicinal products. Generally, the values were within specification (certified values) provided by the manufactures. The results were in agreement with NMR quantification using an internal standard and validated reference HPLC analysis. The PULCON method was found to be a practical alternative with competitive precision and accuracy to the classical internal reference method and it proved to be applicable to different solvent conditions. The method can be recommended for routine use in medicines control laboratories, especially when the availability and costs of reference compounds are problematic. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Ensuring the reliability of stable isotope ratio data--beyond the principle of identical treatment.

    PubMed

    Carter, J F; Fry, B

    2013-03-01

    The need for inter-laboratory comparability is crucial to facilitate the globalisation of scientific networks and the development of international databases to support scientific and criminal investigations. This article considers what lessons can be learned from a series of inter-laboratory comparison exercises organised by the Forensic Isotope Ratio Mass Spectrometry (FIRMS) network in terms of reference materials (RMs), the management of data quality, and technical limitations. The results showed that within-laboratory precision (repeatability) was generally good but between-laboratory accuracy (reproducibility) called for improvements. This review considers how stable isotope laboratories can establish a system of quality control (QC) and quality assurance (QA), emphasising issues of repeatability and reproducibility. For results to be comparable between laboratories, measurements must be traceable to the international δ-scales and, because isotope ratio measurements are reported relative to standards, a key aspect is the correct selection, calibration, and use of international and in-house RMs. The authors identify four principles which promote good laboratory practice. The principle of identical treatment by which samples and RMs are processed in an identical manner and which incorporates three further principles; the principle of identical correction (by which necessary corrections are identified and evenly applied), the principle of identical scaling (by which data are shifted and stretched to the international δ-scales), and the principle of error detection by which QC and QA results are monitored and acted upon. To achieve both good repeatability and good reproducibility it is essential to obtain RMs with internationally agreed δ-values. These RMs will act as the basis for QC and can be used to calibrate further in-house QC RMs tailored to the activities of specific laboratories. In-house QA standards must also be developed to ensure that QC-based calibrations and corrections lead to accurate results for samples. The δ-values assigned to RMs must be recorded and reported with all data. Reference materials must be used to determine what corrections are necessary for measured data. Each analytical sequence of samples must include both QC and QA materials which are subject to identical treatment during measurement and data processing. Results for these materials must be plotted, monitored, and acted upon. Periodically international RMs should be analysed as an in-house proficiency test to demonstrate results are accurate.

  12. Annotated bibliography of software engineering laboratory literature

    NASA Technical Reports Server (NTRS)

    Groves, Paula; Valett, Jon

    1990-01-01

    An annotated bibliography of technical papers, documents, and memorandums produced by or related to the Software Engineering Laboratory is given. More than 100 publications are summarized. These publications cover many areas of software engineering and range from research reports to software documentation. This document has been updated and reorganized substantially since the original version (SEL-82-006, November 1982). All materials have been grouped into eight general subject areas for easy reference: the Software Engineering Laboratory; the Software Engineering Laboratory-software development documents; software tools; software models; software measurement; technology evaluations; Ada technology; and data collection. Subject and author indexes further classify these documents by specific topic and individual author.

  13. Annotated bibliography of Software Engineering Laboratory literature

    NASA Technical Reports Server (NTRS)

    Morusiewicz, Linda; Valett, Jon

    1993-01-01

    This document is an annotated bibliography of technical papers, documents, and memorandums produced by or related to the Software Engineering Laboratory. Nearly 200 publications are summarized. These publications cover many areas of software engineering and range from research reports to software documentation. This document has been updated and reorganized substantially since the original version (SEL-82-006, November 1982). All materials have been grouped into eight general subject areas for easy reference: the Software Engineering Laboratory; the Software Engineering Laboratory: software development documents; software tools; software models; software measurement; technology evaluations; Ada technology; and data collection. This document contains an index of these publications classified by individual author.

  14. Deriving proper measurement uncertainty from Internal Quality Control data: An impossible mission?

    PubMed

    Ceriotti, Ferruccio

    2018-03-30

    Measurement uncertainty (MU) is a "non-negative parameter characterizing the dispersion of the quantity values being attributed to a measurand, based on the information used". In the clinical laboratory the most convenient way to calculate MU is the "top down" approach based on the use of Internal Quality Control data. As indicated in the definition, MU depends on the information used for its calculation and so different estimates of MU can be obtained. The most problematic aspect is how to deal with bias. In fact bias is difficult to detect and quantify and it should be corrected including only the uncertainty derived from this correction. Several approaches to calculate MU starting from Internal Quality Control data are presented. The minimum requirement is to use only the intermediate precision data, provided to include 6 months of results obtained with a commutable quality control material at a concentration close to the clinical decision limit. This approach is the minimal requirement and it is convenient for all those measurands that are especially used for monitoring or where a reference measurement system does not exist and so a reference for calculating the bias is lacking. Other formulas including the uncertainty of the value of the calibrator, including the bias from a commutable certified reference material or from a material specifically prepared for trueness verification, including the bias derived from External Quality Assessment schemes or from historical mean of the laboratory are presented and commented. MU is an important parameter, but a single, agreed upon way to calculate it in a clinical laboratory is not yet available. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  15. High resolution ID-ICP-MS certification of an estuary water reference material (LGC 6016) and analysis of matrix induced polyatomic interferences.

    PubMed

    Evans, P; Fairman, B

    2001-10-01

    Reliable trace metal analysis of environmental samples is dependent upon the availability of high accuracy, matrix reference standards. Here, we present Cd, Cu, Ni, Pb and Zn isotope dilution determination for an estuary water certified reference material (LGC 6016). This work highlights the need for high-accuracy techniques in the development of trace element CRMs rather than conventional inter-laboratory trials. Certification of the estuary water LGC6016 was initially determined from a consensus mean from 14 laboratories but this was found to be unsatisfactory due to the large discrepancies in the reported concentrations. The material was re-analysed using isotope dilution ICP-MS techniques. Pb and Cd were determined using a conventional quadrupole ICP-MS (Elan 5000). Cu, Zn and Ni were determined using a magnetic sector ICP-MS (Finnigan Element), which allowed significant polyatomic interferences to be overcome. Using the magnetic sector instrument, precise mass calibration to within 0.02 amu permitted identification of the interferences. Most interferences derived from the sample matrix. For example, the high Na content causes interferences on 63Cu, due to the formation of 40Ar23Na and 23Na2 16O1H, which in a conventional quadrupole instrument would relate to an erroneous increase in signal intensity by up to 20%. For each analyte a combined uncertainty calculation was performed following the Eurachem/GTAC and ISO guideline. For each element a combined uncertainty of 2-3% was found, which represents a 10-fold improvement compared to certification by inter-laboratory comparison. Analysis of the combined uncertainty budget indicates that the majority of systematic uncertainty derives from the instrumental isotope ratio measurements.

  16. Statistical Analysis of a Round-Robin Measurement Survey of Two Candidate Materials for a Seebeck Coefficient Standard Reference Material

    PubMed Central

    Lu, Z. Q. J.; Lowhorn, N. D.; Wong-Ng, W.; Zhang, W.; Thomas, E. L.; Otani, M.; Green, M. L.; Tran, T. N.; Caylor, C.; Dilley, N. R.; Downey, A.; Edwards, B.; Elsner, N.; Ghamaty, S.; Hogan, T.; Jie, Q.; Li, Q.; Martin, J.; Nolas, G.; Obara, H.; Sharp, J.; Venkatasubramanian, R.; Willigan, R.; Yang, J.; Tritt, T.

    2009-01-01

    In an effort to develop a Standard Reference Material (SRM™) for Seebeck coefficient, we have conducted a round-robin measurement survey of two candidate materials—undoped Bi2Te3 and Constantan (55 % Cu and 45 % Ni alloy). Measurements were performed in two rounds by twelve laboratories involved in active thermoelectric research using a number of different commercial and custom-built measurement systems and techniques. In this paper we report the detailed statistical analyses on the interlaboratory measurement results and the statistical methodology for analysis of irregularly sampled measurement curves in the interlaboratory study setting. Based on these results, we have selected Bi2Te3 as the prototype standard material. Once available, this SRM will be useful for future interlaboratory data comparison and instrument calibrations. PMID:27504212

  17. A Collaborative Study: Determination of Mycotoxins in Corn, Peanut Butter, and Wheat Flour Using Stable Isotope Dilution Assay (SIDA) and Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS).

    PubMed

    Zhang, Kai; Schaab, Matthew R; Southwood, Gavin; Tor, Elizabeth R; Aston, Linda S; Song, Wenlu; Eitzer, Brian; Majumdar, Sanghamitra; Lapainis, Theodore; Mai, Huy; Tran, Kevin; El-Demerdash, Aref; Vega, Victor; Cai, Yanxuan; Wong, Jon W; Krynitsky, Alexandra J; Begley, Timothy H

    2017-08-23

    A collaborative study was conducted to evaluate stable isotope dilution assay (SIDA) and LC-MS/MS for the simultaneous determination of aflatoxins B 1 , B 2 , G 1 , and G 2 ; deoxynivalenol; fumonisins B 1 , B 2 , and B 3 ; ochratoxin A; HT-2 toxin; T-2 toxin; and zearalenone in foods. Samples were fortified with 12 13 C uniformly labeled mycotoxins ( 13 C-IS) corresponding to the native mycotoxins and extracted with acetonitrile/water (50:50 v/v), followed by centrifugation, filtration, and LC-MS/MS analysis. In addition to certified reference materials, the six participating laboratories analyzed corn, peanut butter, and wheat flour fortified with the 12 mycotoxins at concentrations ranging from 1.0 to 1000 ng/g. Using their available LC-MS/MS platform, each laboratory developed in-house instrumental conditions for analysis. The majority of recoveries ranged from 80 to 120% with relative standard derivations (RSDs) <20%. Greater than 90% of the average recoveries of the participating laboratories were in the range of 90-110%, with repeatability RSD r (within laboratory) < 10% and reproducibility RSD R (among laboratory) < 15%. All Z scores of the results of certified reference materials were between -2 and 2. Using 13 C-IS eliminated the need for matrix-matched calibration standards for quantitation, simplified sample preparation, and achieved simultaneous identification and quantitation of multiple mycotoxins in a simple LC-MS/MS procedure.

  18. Re-evaluation and extension of the scope of elements in US Geological Survey Standard Reference Water Samples

    USGS Publications Warehouse

    Peart, D.B.; Antweiler, Ronald C.; Taylor, Howard E.; Roth, D.A.; Brinton, T.I.

    1998-01-01

    More than 100 US Geological Survey (USGS) Standard Reference Water Samples (SRWSs) were analyzed for numerous trace constituents, including Al, As, B, Ba, Be, Bi, Br, Cd, Cr, Co, Cu, I, Fe, Pb, Li, Mn, Mo, Ni, Rb, Sb, Se, Sr, Te, Tl, U, V, Zn and major elements (Ca, Mg, Na, SiO2, SO4, Cl) by inductively coupled plasma mass spectrometry and inductively coupled plasma atomic emission spectrometry. In addition, 15 USGS SRWSs and National Institute of Standards and Technology (NIST) standard reference material (SRM) 1641b were analyzed for mercury using cold vapor atomic fluorescence spectrometry. Also USGS SRWS Hg-7 was analyzed using isotope dilution-inductively coupled plasma mass spectrometry. The results were compared with the reported certified values of the following standard reference materials: NIST SRM 1643a, 1643b, 1643c and 1643d and National Research Council of Canada Riverine Water Reference Materials for Trace Metals SLRS-1, SLRS-2 and SLRS-3. New concentration values for trace and major elements in the SRWSs, traceable to the certified standards, are reported. Additional concentration values are reported for elements that were neither previously published for the SRWSs nor traceable to the certified reference materials. Robust statistical procedures were used that were insensitive to outliers. These data can be used for quality assurance/quality control purposes in analytical laboratories.

  19. The design of temporary sediment controls with special reference to water quality.

    DOT National Transportation Integrated Search

    1975-01-01

    The laboratory and field trapping efficiencies of several types of flow barriers were ascertained. The materials used to fabricate the barriers were various types of hay straw crushed stone and crushed stone/straw mixes. Field checks of systems of ba...

  20. 46 CFR 160.076-11 - Incorporation by reference.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... the public. All approved material is available for inspection at the National Archives and Records Administration (NARA) and at Coast Guard Headquarters. Contact Commandant (CG-ENG-4), Attn: Lifesaving and Fire.../federal_register/code_of_federal_regulations/ibr_locations.html. (b) Underwriters Laboratories (UL...

  1. 46 CFR 160.076-11 - Incorporation by reference.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... the public. All approved material is available for inspection at the National Archives and Records Administration (NARA) and at Coast Guard Headquarters. Contact Commandant (CG-ENG-4), Attn: Lifesaving and Fire.../federal_register/code_of_federal_regulations/ibr_locations.html. (b) Underwriters Laboratories (UL...

  2. The Source Book of Marine Sciences.

    ERIC Educational Resources Information Center

    Bergen, Bob; And Others

    Intended primarily for the secondary level, this manual presents 35 laboratory and field activities in marine science. Also included are chapters which cover field trip logistics, marine science centers, films, and reference materials. Typical amonq the lessons are "Charting Local Current Systems,""Salinity,""Living World Within a…

  3. New NIST sediment SRM for inorganic analysis.

    PubMed

    Zeisler, Rolf

    2004-03-01

    NIST maintains a portfolio of more than 1300 standard reference materials (SRM), more than a third of these relating to measurements in the biological and environmental fields. As part of the continuous renewal and replacement efforts, a set of new marine sediments has been recently developed covering organic and inorganic determinations. This paper describes the steps taken in sample preparation, homogeneity assay, and analytical characterization and certification with specific emphasis on SRM 2702 inorganics in marine sediment. Neutron activation analysis showed the SRM to be highly homogeneous, opening the possibility for use with solid sampling techniques. The certificate provides certified mass fraction values for 25 elements, reference values for eight elements, and information values for 11 elements, covering most of the priority pollutants with small uncertainties of only several percent relative. The values were obtained by combining results from different laboratories and techniques using a Bayesian statistical model. An intercomparison carried out in field laboratories with the material before certification illustrates a high commutability of this SRM.

  4. Preventing Supercooling Of Gallium

    NASA Technical Reports Server (NTRS)

    Massucco, Arthur A.; Wenghoefer, Hans M.; Wilkins, Ronnie

    1994-01-01

    Principle of heterogeneous nucleation exploited to prevent gallium from supercooling, enabling its use as heat-storage material that crystallizes reproducibly at its freezing or melting temperature of 29 to 30 degrees C. In original intended application, gallium used as heat-storage material in gloves of space suits. Terrestrial application lies in preparation of freezing-temperature reference samples for laboratories. Principle of heterogeneous nucleation also exploited similarly in heat pipes filled with sodium.

  5. Dynamic Shock Compression of Copper to Multi-Megabar Pressure

    NASA Astrophysics Data System (ADS)

    Haill, T. A.; Furnish, M. D.; Twyeffort, L. L.; Arrington, C. L.; Lemke, R. W.; Knudson, M. D.; Davis, J.-P.

    2015-11-01

    Copper is an important material for a variety of shock and high energy density applications and experiments. Copper is used as a standard reference material to determine the EOS properties of other materials. The high conductivity of copper makes it useful as an MHD driver layer in high current dynamic materials experiments on Sandia National Laboratories Z machine. Composite aluminum/copper flyer plates increase the dwell time in plate impact experiments by taking advantage of the slower wave speeds in copper. This presentation reports on recent efforts to reinstate a composite Al/Cu flyer capability on Z and to extend the range of equation-of-state shock compression data through the use of hyper-velocity composite flyers and symmetric planar impact with copper targets. We will present results from multi-dimensional ALEGRA MHD simulations, as well as experimental designs and methods of composite flyer fabrication. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Company, for the U.S. DOE's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  6. Post hoc interlaboratory comparison of single particle ICP-MS size measurements of NIST gold nanoparticle reference materials.

    PubMed

    Montoro Bustos, Antonio R; Petersen, Elijah J; Possolo, Antonio; Winchester, Michael R

    2015-09-01

    Single particle inductively coupled plasma-mass spectrometry (spICP-MS) is an emerging technique that enables simultaneous measurement of nanoparticle size and number quantification of metal-containing nanoparticles at realistic environmental exposure concentrations. Such measurements are needed to understand the potential environmental and human health risks of nanoparticles. Before spICP-MS can be considered a mature methodology, additional work is needed to standardize this technique including an assessment of the reliability and variability of size distribution measurements and the transferability of the technique among laboratories. This paper presents the first post hoc interlaboratory comparison study of the spICP-MS technique. Measurement results provided by six expert laboratories for two National Institute of Standards and Technology (NIST) gold nanoparticle reference materials (RM 8012 and RM 8013) were employed. The general agreement in particle size between spICP-MS measurements and measurements by six reference techniques demonstrates the reliability of spICP-MS and validates its sizing capability. However, the precision of the spICP-MS measurement was better for the larger 60 nm gold nanoparticles and evaluation of spICP-MS precision indicates substantial variability among laboratories, with lower variability between operators within laboratories. Global particle number concentration and Au mass concentration recovery were quantitative for RM 8013 but significantly lower and with a greater variability for RM 8012. Statistical analysis did not suggest an optimal dwell time, because this parameter did not significantly affect either the measured mean particle size or the ability to count nanoparticles. Finally, the spICP-MS data were often best fit with several single non-Gaussian distributions or mixtures of Gaussian distributions, rather than the more frequently used normal or log-normal distributions.

  7. EDQM biological reference preparation for rabies vaccine (inactivated) for veterinary use.

    PubMed

    Daas, A; Bruckner, L; Milne, C

    2015-01-01

    Rabies is a deadly zoonotic disease. Control of rabies in animals by vaccination is an important strategy to protect humans from infection and control the spread of the disease. Requirements for the quality control of rabies vaccines (inactivated) for veterinary use include an in vivo quantitative potency determination as outlined in the Ph. Eur. monograph 0451. Performance of this assay requires a reference preparation calibrated in International Units (IU). A European Pharmacopeia (Ph. Eur.) Biological Reference Preparation (BRP) for rabies vaccines (inactivated) for veterinary use, calibrated in IU, has been established for this purpose. Due to the dwindling stocks of the current batch (batch 4) of Ph. Eur. BRP for rabies vaccines (inactivated) for veterinary use, a collaborative study was run as part of the EDQM Biological Standardisation Programme to establish BRP batch 5. Ten laboratories, including Official Medicines Control Laboratories and manufacturers, participated. The candidate BRP5 was assayed against the 6(th) International Standard for rabies vaccine using the in vivo vaccination-challenge assay (monograph 0451) to assign a potency value. The candidate was also compared to BRP batch 4 to establish continuity. Taking into account the results from the comparisons a potency of 10 IU/vial was assigned and in March 2015 the Ph. Eur. Commission adopted the material as Ph. Eur. BRP for rabies vaccines (inactivated) for veterinary use batch 5. In addition to the in vivo assay 3 laboratories tested the candidate material using their in-house in vitro assays for information.

  8. Annotated bibliography of Software Engineering Laboratory literature

    NASA Technical Reports Server (NTRS)

    1985-01-01

    An annotated bibliography of technical papers, documents, and memorandums produced by or related to the Software Engineering Laboratory is presented. More than 100 publications are summarized. These publications are summarized. These publications cover many areas of software engineering and range from research reports to software documentation. This document has been updated and reorganized substantially since the original version (SEL-82-006, November 1982). All materials are grouped into five general subject areas for easy reference: (1) the software engineering laboratory; (2) software tools; (3) models and measures; (4) technology evaluations; and (5) data collection. An index further classifies these documents by specific topic.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lindahl, P.C.

    A proposed American Society for Testing and Materials (ASTM) method for the determination of arsenic and selenium content in coal has been used and evaluated in the Analytical Chemistry Laboratory (ACL) at Argonne National Laboratory (ANL) as part of an interlaboratory study. Coal is conducted with Eschka's mixture (MgO + Na/sub 2/CO/sub 3/), followed by determination of the aresnic and selenium content by hydride generation/atomic absorption spectrophotometry. The method was evaluated on a series of coals, including two National Bureau of Standards-Standards Reference Material (NBS-SRM) coals and twelve ASTM coal samples. Comparison of ACL/ANL arsenic and selenium data for themore » suite of coal analyzed showed excellent agreement with certified values for the NBS-SRM coals and with interlaboratory data from five other laboratories for the ASTM coals. 11 refs., 3 figs., 6 tabs.« less

  10. REFERENCE MATERIALS FOR WATER AND WASTEWATER ANALYSES IN USEPA (U.S. ENVIRONMENTAL PROTECTION AGENCY)

    EPA Science Inventory

    The Environmental Monitoring and Support Laboratory at Cincinnati provides quality assurance support for EPA's water-related programs in response to the Clean Water Act, the Safe Drinking Water Act, the Marine Protection, Research and Sanctuaries Act, the Resources Conservation a...

  11. TRACE ELEMENT ANALYSES OF URANIUM MATERIALS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beals, D; Charles Shick, C

    The Savannah River National Laboratory (SRNL) has developed an analytical method to measure many trace elements in a variety of uranium materials at the high part-per-billion (ppb) to low part-per-million (ppm) levels using matrix removal and analysis by quadrapole ICP-MS. Over 35 elements were measured in uranium oxides, acetate, ore and metal. Replicate analyses of samples did provide precise results however none of the materials was certified for trace element content thus no measure of the accuracy could be made. The DOE New Brunswick Laboratory (NBL) does provide a Certified Reference Material (CRM) that has provisional values for a seriesmore » of trace elements. The NBL CRM were purchased and analyzed to determine the accuracy of the method for the analysis of trace elements in uranium oxide. These results are presented and discussed in the following paper.« less

  12. Implementation of a reference standard and proficiency testing programme by the World Wide Antimalarial Resistance Network (WWARN)

    PubMed Central

    2010-01-01

    Background The Worldwide Antimalarial Resistance Network (WWARN) is a global collaboration to support the objective that anyone affected by malaria receives effective and safe drug treatment. The Pharmacology module aims to inform optimal anti-malarial drug selection. There is an urgent need to define the drug exposure - effect relationship for most anti-malarial drugs. Few anti-malarials have had their therapeutic blood concentration levels defined. One of the main challenges in assessing safety and efficacy data in relation to drug concentrations is the comparability of data generated from different laboratories. To explain differences in anti-malarial pharmacokinetics in studies with different measurement laboratories it is necessary to confirm the accuracy of the assay methods. This requires the establishment of an external quality assurance process to assure results that can be compared. This paper describes this process. Methods The pharmacology module of WWARN has established a quality assurance/quality control (QA/QC) programme consisting of two separate components: 1. A proficiency testing programme where blank human plasma spiked with certified reference material (CRM) in different concentrations is sent out to participating bioanalytical laboratories. 2. A certified reference standard programme where accurately weighed amounts of certified anti-malarial reference standards, metabolites, and internal standards are sent to participating bioanalytical and in vitro laboratories. Conclusion The proficiency testing programme is designed as a cooperative effort to help participating laboratories assess their ability to carry out drug analysis, resolve any potential problem areas and to improve their results - and, in so doing, to improve the quality of anti-malarial pharmacokinetic data published and shared with WWARN. By utilizing the same source of standards for all laboratories, it is possible to minimize bias arising from poor quality reference standards. By providing anti-malarial drug standards from a central point, it is possible to lower the cost of these standards. PMID:21184684

  13. Development of the Global Measles Laboratory Network.

    PubMed

    Featherstone, David; Brown, David; Sanders, Ray

    2003-05-15

    The routine reporting of suspected measles cases and laboratory testing of samples from these cases is the backbone of measles surveillance. The Global Measles Laboratory Network (GMLN) has developed standards for laboratory confirmation of measles and provides training resources for staff of network laboratories, reference materials and expertise for the development and quality control of testing procedures, and accurate information for the Measles Mortality Reduction and Regional Elimination Initiative. The GMLN was developed along the lines of the successful Global Polio Laboratory Network, and much of the polio laboratory infrastructure was utilized for measles. The GMLN has developed as countries focus on measles control activities following successful eradication of polio. Currently more than 100 laboratories are part of the global network and follow standardized testing and reporting procedures. A comprehensive laboratory accreditation process will be introduced in 2002 with six quality assurance and performance indicators.

  14. Quality-assurance plan for the analysis of fluvial sediment by the U.S. Geological Survey Kentucky Water Science Center Sediment Laboratory

    USGS Publications Warehouse

    Shreve, Elizabeth A.; Downs, Aimee C.

    2005-01-01

    This report describes laboratory procedures used by the U.S. Geological Survey Kentucky Water Science Center Sediment Laboratory for the processing and analysis of fluvial-sediment samples for concentration of sand and finer material. The report details the processing of a sediment sample through the laboratory from receiving the sediment sample, through the analytical process, to compiling results of the requested analysis. Procedures for preserving sample integrity, calibrating and maintaining of laboratory and field instruments and equipment, analyzing samples, internal quality assurance and quality control, and validity of the sediment-analysis results also are described. The report includes a list of references cited and a glossary of sediment and quality-assurance terms.

  15. Software engineering laboratory series: Annotated bibliography of software engineering laboratory literature

    NASA Technical Reports Server (NTRS)

    Morusiewicz, Linda; Valett, Jon

    1992-01-01

    This document is an annotated bibliography of technical papers, documents, and memorandums produced by or related to the Software Engineering Laboratory. More than 100 publications are summarized. These publications cover many areas of software engineering and range from research reports to software documentation. This document has been updated and reorganized substantially since the original version (SEL-82-006, November 1982). All materials have been grouped into eight general subject areas for easy reference: (1) the Software Engineering Laboratory; (2) the Software Engineering Laboratory: Software Development Documents; (3) Software Tools; (4) Software Models; (5) Software Measurement; (6) Technology Evaluations; (7) Ada Technology; and (8) Data Collection. This document contains an index of these publications classified by individual author.

  16. An International Proficiency Test to Detect, Identify and Quantify Ricin in Complex Matrices

    PubMed Central

    Worbs, Sylvia; Skiba, Martin; Bender, Jennifer; Zeleny, Reinhard; Schimmel, Heinz; Luginbühl, Werner; Dorner, Brigitte G.

    2015-01-01

    While natural intoxications with seeds of Ricinus communis (R. communis) have long been known, the toxic protein ricin contained in the seeds is of major concern since it attracts attention of those intending criminal, terroristic and military misuse. In order to harmonize detection capabilities in expert laboratories, an international proficiency test was organized that aimed at identifying good analytical practices (qualitative measurements) and determining a consensus concentration on a highly pure ricin reference material (quantitative measurements). Sample materials included highly pure ricin as well as the related R. communis agglutinin (RCA120) spiked into buffer, milk and meat extract; additionally, an organic fertilizer naturally contaminated with R. communis shred was investigated in the proficiency test. The qualitative results showed that either a suitable combination of immunological, mass spectrometry (MS)-based and functional approaches or sophisticated MS-based approaches alone successfully allowed the detection and identification of ricin in all samples. In terms of quantification, it was possible to determine a consensus concentration of the highly pure ricin reference material. The results provide a basis for further steps in quality assurance and improve biopreparedness in expert laboratories worldwide. PMID:26703726

  17. An International Proficiency Test to Detect, Identify and Quantify Ricin in Complex Matrices.

    PubMed

    Worbs, Sylvia; Skiba, Martin; Bender, Jennifer; Zeleny, Reinhard; Schimmel, Heinz; Luginbühl, Werner; Dorner, Brigitte G

    2015-11-26

    While natural intoxications with seeds of Ricinus communis (R. communis) have long been known, the toxic protein ricin contained in the seeds is of major concern since it attracts attention of those intending criminal, terroristic and military misuse. In order to harmonize detection capabilities in expert laboratories, an international proficiency test was organized that aimed at identifying good analytical practices (qualitative measurements) and determining a consensus concentration on a highly pure ricin reference material (quantitative measurements). Sample materials included highly pure ricin as well as the related R. communis agglutinin (RCA120) spiked into buffer, milk and meat extract; additionally, an organic fertilizer naturally contaminated with R. communis shred was investigated in the proficiency test. The qualitative results showed that either a suitable combination of immunological, mass spectrometry (MS)-based and functional approaches or sophisticated MS-based approaches alone successfully allowed the detection and identification of ricin in all samples. In terms of quantification, it was possible to determine a consensus concentration of the highly pure ricin reference material. The results provide a basis for further steps in quality assurance and improve biopreparedness in expert laboratories worldwide.

  18. Metabolite profiling of a NIST Standard Reference Material for human plasma (SRM 1950): GC-MS, LC-MS, NMR, and clinical laboratory analyses, libraries, and web-based resources.

    PubMed

    Simón-Manso, Yamil; Lowenthal, Mark S; Kilpatrick, Lisa E; Sampson, Maureen L; Telu, Kelly H; Rudnick, Paul A; Mallard, W Gary; Bearden, Daniel W; Schock, Tracey B; Tchekhovskoi, Dmitrii V; Blonder, Niksa; Yan, Xinjian; Liang, Yuxue; Zheng, Yufang; Wallace, William E; Neta, Pedatsur; Phinney, Karen W; Remaley, Alan T; Stein, Stephen E

    2013-12-17

    Recent progress in metabolomics and the development of increasingly sensitive analytical techniques have renewed interest in global profiling, i.e., semiquantitative monitoring of all chemical constituents of biological fluids. In this work, we have performed global profiling of NIST SRM 1950, "Metabolites in Human Plasma", using GC-MS, LC-MS, and NMR. Metabolome coverage, difficulties, and reproducibility of the experiments on each platform are discussed. A total of 353 metabolites have been identified in this material. GC-MS provides 65 unique identifications, and most of the identifications from NMR overlap with the LC-MS identifications, except for some small sugars that are not directly found by LC-MS. Also, repeatability and intermediate precision analyses show that the SRM 1950 profiling is reproducible enough to consider this material as a good choice to distinguish between analytical and biological variability. Clinical laboratory data shows that most results are within the reference ranges for each assay. In-house computational tools have been developed or modified for MS data processing and interactive web display. All data and programs are freely available online at http://peptide.nist.gov/ and http://srmd.nist.gov/ .

  19. [Tasks and duties of veterinary reference laboratories for food borne zoonoses].

    PubMed

    Ellerbroek, Lüppo; Alter, T; Johne, R; Nöckler, K; Beutin, L; Helmuth, R

    2009-02-01

    Reference laboratories are of central importance for consumer protection. Field expertise and high scientific competence are basic requirements for the nomination of a national reference laboratory. To ensure a common approach in the analysis of zoonotic hazards, standards have been developed by the reference laboratories together with national official laboratories on the basis of Art. 33 of Directive (EG) No. 882/2004. Reference laboratories function as arbitrative boards in the case of ambivalent or debatable results. New methods for detection of zoonotic agents are developed and validated to provide tools for analysis, e. g., in legal cases, if results from different parties are disputed. Besides these tasks, national reference laboratories offer capacity building and advanced training courses and control the performance of ring trials to ensure consistency in the quality of analyses in official laboratories. All reference laboratories work according to the ISO standard 17025 which defines the grounds for strict laboratory quality rules and in cooperation with the respective Community Reference Laboratories (CRL). From the group of veterinary reference laboratories for food-borne zoonoses, the national reference laboratories are responsible for Listeria monocytogenes, for Campylobacter, for the surveillance and control of viral and bacterial contamination of bivalve molluscs, for E. coli, for the performance of analysis and tests on zoonoses (Salmonella), and from the group of parasitological zoonotic agents, the national reference laboratory for Trichinella.

  20. [Reference values for the blood coagulation tests in Mexico: usefulness of the pooled plasma from blood donors].

    PubMed

    Calzada-Contreras, Adriana; Moreno-Hernández, Manuel; Castillo-Torres, Noemi Patricia; Souto-Rosillo, Guadalupe; Hernández-Juárez, Jesús; Ricardo-Moreno, María Tania; Sánchez-Fernández, Maria Guadalupe de Jesús; García-González, América; Majluf-Cruz, Abraham

    2012-01-01

    The blood coagulation system maintains the blood in a liquid state and bleeding and thrombosis are the manifestations of its malfunction. Blood coagulation laboratory evaluates the physiology of this system. To establish both, the reference values for several tests performed at the blood coagulation laboratory as well as the utility of the pooled plasma to perform these assays. MATERIAL AND: In this descriptive, cross-sectional, randomized study, we collected plasma from Mexican Mestizos. Each pooled plasma was prepared with the plasma from at least 20 blood donors. We performed screening and special tests and the Levey-Jennings graphs were built and interpreted after each pass. Results of the tests were analyzed and their distribution was established using the Kolmogorov-Smirnov test. To establish the reference values we used 95% confidence intervals. We collected 72 pooled plasmas. The distribution for PT, APTT, and TT tests was abnormal. Although the PT test showed a bimodal distribution it was normal for factor VII. The reference values for the hemostatic, anticoagulant, and fibrinolytic factors were different from those suggested by the manufacturers. We established the reference values for the blood coagulation tests in the adult Mexican population. We have shown that the pooled plasma must be used for the screening tests. We suggest that each clinical laboratory should establish its own reference values (at least for the screening tests). To reach this objective, we encourage the use of the pooled plasma.

  1. Quality Assurance Program for Molecular Medicine Laboratories

    PubMed Central

    Hajia, M; Safadel, N; Samiee, S Mirab; Dahim, P; Anjarani, S; Nafisi, N; Sohrabi, A; Rafiee, M; Sabzavi, F; Entekhabi, B

    2013-01-01

    Background: Molecular diagnostic methods have played and continuing to have a critical role in clinical laboratories in recent years. Therefore, standardization is an evolutionary process that needs to be upgrade with increasing scientific knowledge, improvement of the instruments and techniques. The aim of this study was to design a quality assurance program in order to have similar conditions for all medical laboratories engaging with molecular tests. Methods: We had to design a plan for all four elements; required space conditions, equipments, training, and basic guidelines. Necessary guidelines was prepared and confirmed by the launched specific committee at the Health Reference Laboratory. Results: Several workshops were also held for medical laboratories directors and staffs, quality control manager of molecular companies, directors and nominees from universities. Accreditation of equipments and molecular material was followed parallel with rest of program. Now we are going to accredit medical laboratories and to evaluate the success of the program. Conclusion: Accreditation of medical laboratory will be succeeding if its basic elements are provided in advance. Professional practice guidelines, holding training and performing accreditation the molecular materials and equipments ensured us that laboratories are aware of best practices, proper interpretation, limitations of techniques, and technical issues. Now, active external auditing can improve the applied laboratory conditions toward the defined standard level. PMID:23865028

  2. Quality assurance program for molecular medicine laboratories.

    PubMed

    Hajia, M; Safadel, N; Samiee, S Mirab; Dahim, P; Anjarani, S; Nafisi, N; Sohrabi, A; Rafiee, M; Sabzavi, F; Entekhabi, B

    2013-01-01

    Molecular diagnostic methods have played and continuing to have a critical role in clinical laboratories in recent years. Therefore, standardization is an evolutionary process that needs to be upgrade with increasing scientific knowledge, improvement of the instruments and techniques. The aim of this study was to design a quality assurance program in order to have similar conditions for all medical laboratories engaging with molecular tests. We had to design a plan for all four elements; required space conditions, equipments, training, and basic guidelines. Necessary guidelines was prepared and confirmed by the launched specific committee at the Health Reference Laboratory. Several workshops were also held for medical laboratories directors and staffs, quality control manager of molecular companies, directors and nominees from universities. Accreditation of equipments and molecular material was followed parallel with rest of program. Now we are going to accredit medical laboratories and to evaluate the success of the program. Accreditation of medical laboratory will be succeeding if its basic elements are provided in advance. Professional practice guidelines, holding training and performing accreditation the molecular materials and equipments ensured us that laboratories are aware of best practices, proper interpretation, limitations of techniques, and technical issues. Now, active external auditing can improve the applied laboratory conditions toward the defined standard level.

  3. Copy Number Heterogeneity, Large Origin Tandem Repeats, and Interspecies Recombination in Human Herpesvirus 6A (HHV-6A) and HHV-6B Reference Strains

    PubMed Central

    Roychoudhury, Pavitra; Makhsous, Negar; Hanson, Derek; Chase, Jill; Krueger, Gerhard; Xie, Hong; Huang, Meei-Li; Saunders, Lindsay; Ablashi, Dharam; Koelle, David M.; Cook, Linda; Jerome, Keith R.

    2018-01-01

    ABSTRACT Quantitative PCR is a diagnostic pillar for clinical virology testing, and reference materials are necessary for accurate, comparable quantitation between clinical laboratories. Accurate quantitation of human herpesvirus 6A/B (HHV-6A/B) is important for detection of viral reactivation and inherited chromosomally integrated HHV-6A/B in immunocompromised patients. Reference materials in clinical virology commonly consist of laboratory-adapted viral strains that may be affected by the culture process. We performed next-generation sequencing to make relative copy number measurements at single nucleotide resolution of eight candidate HHV-6A and seven HHV-6B reference strains and DNA materials from the HHV-6 Foundation and Advanced Biotechnologies Inc. Eleven of 17 (65%) HHV-6A/B candidate reference materials showed multiple copies of the origin of replication upstream of the U41 gene by next-generation sequencing. These large tandem repeats arose independently in culture-adapted HHV-6A and HHV-6B strains, measuring 1,254 bp and 983 bp, respectively. The average copy number measured was between 5 and 10 times the number of copies of the rest of the genome. We also report the first interspecies recombinant HHV-6A/B strain with a HHV-6A backbone and a >5.5-kb region from HHV-6B, from U41 to U43, that covered the origin tandem repeat. Specific HHV-6A reference strains demonstrated duplication of regions at U1/U2, U87, and U89, as well as deletion in the U12-to-U24 region and the U94/U95 genes. HHV-6A/B strains derived from cord blood mononuclear cells from different laboratories on different continents with fewer passages revealed no copy number differences throughout the viral genome. These data indicate that large origin tandem duplications are an adaptation of both HHV-6A and HHV-6B in culture and show interspecies recombination is possible within the Betaherpesvirinae. IMPORTANCE Anything in science that needs to be quantitated requires a standard unit of measurement. This includes viruses, for which quantitation increasingly determines definitions of pathology and guidelines for treatment. However, the act of making standard or reference material in virology can alter its very accuracy through genomic duplications, insertions, and rearrangements. We used deep sequencing to examine candidate reference strains for HHV-6, a ubiquitous human virus that can reactivate in the immunocompromised population and is integrated into the human genome in every cell of the body for 1% of people worldwide. We found large tandem repeats in the origin of replication for both HHV-6A and HHV-6B that are selected for in culture. We also found the first interspecies recombinant between HHV-6A and HHV-6B, a phenomenon that is well known in alphaherpesviruses but to date has not been seen in betaherpesviruses. These data critically inform HHV-6A/B biology and the standard selection process. PMID:29491155

  4. Establishing the traceability of a uranyl nitrate solution to a standard reference material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jackson, C.H.; Clark, J.P.

    1978-01-01

    A uranyl nitrate solution for use as a Working Calibration and Test Material (WCTM) was characterized, using a statistically designed procedure to document traceability to National Bureau of Standards Reference Material (SPM-960). A Reference Calibration and Test Material (PCTM) was prepared from SRM-960 uranium metal to approximate the acid and uranium concentration of the WCTM. This solution was used in the characterization procedure. Details of preparing, handling, and packaging these solutions are covered. Two outside laboratories, each having measurement expertise using a different analytical method, were selected to measure both solutions according to the procedure for characterizing the WCTM. Twomore » different methods were also used for the in-house characterization work. All analytical results were tested for statistical agreement before the WCTM concentration and limit of error values were calculated. A concentration value was determined with a relative limit of error (RLE) of approximately 0.03% which was better than the target RLE of 0.08%. The use of this working material eliminates the expense of using SRMs to fulfill traceability requirements for uranium measurements on this type material. Several years' supply of uranyl nitrate solution with NBS traceability was produced. The cost of this material was less than 10% of an equal quantity of SRM-960 uranium metal.« less

  5. Protocol and standard operating procedures for common use in a worldwide multicenter study on reference values.

    PubMed

    Ozarda, Yesim; Ichihara, Kiyoshi; Barth, Julian H; Klee, George

    2013-05-01

    The reference intervals (RIs) given in laboratory reports have an important role in aiding clinicians in interpreting test results in reference to values of healthy populations. In this report, we present a proposed protocol and standard operating procedures (SOPs) for common use in conducting multicenter RI studies on a national or international scale. The protocols and consensus on their contents were refined through discussions in recent C-RIDL meetings. The protocol describes in detail (1) the scheme and organization of the study, (2) the target population, inclusion/exclusion criteria, ethnicity, and sample size, (3) health status questionnaire, (4) target analytes, (5) blood collection, (6) sample processing and storage, (7) assays, (8) cross-check testing, (9) ethics, (10) data analyses, and (11) reporting of results. In addition, the protocol proposes the common measurement of a panel of sera when no standard materials exist for harmonization of test results. It also describes the requirements of the central laboratory, including the method of cross-check testing between the central laboratory of each country and local laboratories. This protocol and the SOPs remain largely exploratory and may require a reevaluation from the practical point of view after their implementation in the ongoing worldwide study. The paper is mainly intended to be a basis for discussion in the scientific community.

  6. Annotated bibliography of software engineering laboratory literature

    NASA Technical Reports Server (NTRS)

    Kistler, David; Bristow, John; Smith, Don

    1994-01-01

    This document is an annotated bibliography of technical papers, documents, and memorandums produced by or related to the Software Engineering Laboratory. Nearly 200 publications are summarized. These publications cover many areas of software engineering and range from research reports to software documentation. This document has been updated and reorganized substantially since the original version (SEL-82-006, November 1982). All materials have been grouped into eight general subject areas for easy reference: (1) The Software Engineering Laboratory; (2) The Software Engineering Laboratory: Software Development Documents; (3) Software Tools; (4) Software Models; (5) Software Measurement; (6) Technology Evaluations; (7) Ada Technology; and (8) Data Collection. This document contains an index of these publications classified by individual author.

  7. National Survey of Adult and Pediatric Reference Intervals in Clinical Laboratories across Canada: A Report of the CSCC Working Group on Reference Interval Harmonization.

    PubMed

    Adeli, Khosrow; Higgins, Victoria; Seccombe, David; Collier, Christine P; Balion, Cynthia M; Cembrowski, George; Venner, Allison A; Shaw, Julie

    2017-11-01

    Reference intervals are widely used decision-making tools in laboratory medicine, serving as health-associated standards to interpret laboratory test results. Numerous studies have shown wide variation in reference intervals, even between laboratories using assays from the same manufacturer. Lack of consistency in either sample measurement or reference intervals across laboratories challenges the expectation of standardized patient care regardless of testing location. Here, we present data from a national survey conducted by the Canadian Society of Clinical Chemists (CSCC) Reference Interval Harmonization (hRI) Working Group that examines variation in laboratory reference sample measurements, as well as pediatric and adult reference intervals currently used in clinical practice across Canada. Data on reference intervals currently used by 37 laboratories were collected through a national survey to examine the variation in reference intervals for seven common laboratory tests. Additionally, 40 clinical laboratories participated in a baseline assessment by measuring six analytes in a reference sample. Of the seven analytes examined, alanine aminotransferase (ALT), alkaline phosphatase (ALP), and creatinine reference intervals were most variable. As expected, reference interval variation was more substantial in the pediatric population and varied between laboratories using the same instrumentation. Reference sample results differed between laboratories, particularly for ALT and free thyroxine (FT4). Reference interval variation was greater than test result variation for the majority of analytes. It is evident that there is a critical lack of harmonization in laboratory reference intervals, particularly for the pediatric population. Furthermore, the observed variation in reference intervals across instruments cannot be explained by the bias between the results obtained on instruments by different manufacturers. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  8. The American Association for Laboratory Accreditation

    DTIC Science & Technology

    2011-03-28

    ISO / IEC 17025 ...Information Technology A2LA DoD ELAP Program n All labs are assessed to ISO / IEC 17025 :2005 as the base standard. n In addition, the requirements of 2003...n Inspection Body Accreditation ( ISO / IEC 17020) n Proficiency Testing Providers ( ISO / IEC 17043) n Reference Materials Producers ( ISO Guide

  9. Particulate Meso-scale Mechanics Diagnostics: Magnetic Sensors for Dynamic State Orientation

    DTIC Science & Technology

    2013-12-01

    Research Laboratory for giving this opportunity to work at the Eglin AFB, FL. REFERENCES 1. Brian D. Reding , “Development of Particulate Materials...Measurements," Sandia Report, 1984. 15. I.N. Tansel, B. Reding , W. L. Cooper, “Lagrangian Point State Estimation with Optimized, Redundant Induction Coil

  10. Recycling research progress at the Forest Products Laboratory.

    Treesearch

    1995-01-01

    This document summarizes accomplishments of USDA Forest Service researchers in the area of recycling. Specifically, it describes work in economic assessment, paper recycling, recycled housing and industrial applications of recycled materials, other recycling applications, and technology transfer. The literature list includes the references cited in the text and...

  11. Quality assurance for health and environmental chemistry: 1990

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gautier, M.A.; Gladney, E.S.; Koski, N.L.

    1991-10-01

    This report documents the continuing quality assurance efforts of the Health and Environmental Chemistry Group (HSE-9) at the Los Alamos National Laboratory. The philosophy, methodology, computing resources, and laboratory information management system used by the quality assurance program to encompass the diversity of analytical chemistry practiced in the group are described. Included in the report are all quality assurance reference materials used, along with their certified or consensus concentrations, and all analytical chemistry quality assurance measurements made by HSE-9 during 1990.

  12. Electronic reporting of all reference laboratory results: An important step toward a truly all-encompassing, integrated health record.

    PubMed

    Kratz, Alexander

    2016-09-01

    Results from reference laboratories are often not easily available in electronic health records. This article describes a multi-pronged, long-term approach that includes bringing send-out tests in-house, upgrading the laboratory information system, interfacing more send-out tests and more reference laboratories, utilizing the "miscellaneous assay" option offered by some reference laboratories, and scanning all remaining paper reports from reference laboratories for display in the electronic health record. This allowed all laboratory results obtained in association with a patient visit, whether performed in-house or at a reference laboratory, to be available in the integrated electronic health record. This was achieved without manual data entry of reference laboratory results, thereby avoiding the risk of transcription errors. A fully integrated electronic health record that contains all laboratory results can be achieved by maximizing the number of interfaced reference laboratory assays and making all non-interfaced results available as scanned documents. © The Author(s) 2015.

  13. Certification of the methylmercury content in SRM 2977 mussel tissue (organic contaminants and trace elements) and SRM 1566b oyster tissue.

    PubMed

    Tutschku, S; Schantz, M M; Horvat, M; Logar, M; Akagi, H; Emons, H; Levenson, M; Wise, S A

    2001-02-01

    The methylmercury content in two new marine bivalve mollusk tissue Standard Reference Materials (SRMs) has been certified using results of analyses from the National Institute of Standards and Technology (NIST) and two other laboratories. The certified concentrations of methylmercury were established based on the results from four and six different (independent) analytical methods, respectively, for SRM 1566b Oyster Tissue (13.2 +/- 0.7 microg/kg) and SRM 2977 Mussel Tissue (organic contaminants and trace elements) (36.2 +/- 1.7 microg/kg). The certified concentration of methylmercury in SRM 1566b is among the lowest in any certified reference material (CRM).

  14. Evaluation of critical indicators in the process of acquiring supplies and services LAC-UFPE

    NASA Astrophysics Data System (ADS)

    Caetano, V. F.; Ferreira, C. V.; dos Santos, M. J.; Honorato, F. A.

    2015-01-01

    In laboratories linked to public universities and accredited by the NBR ISO/IEC 17025, to meet efficiently item 4.6 (procurement of supplies and services) is a challenge that can be accomplished by programming based on historical purchases and services. In this study, we evaluated the critical procurement items to meet the quality management system of the LAC-UFPE: reagents, certified reference material, of equipment parts, maintenance and calibration of equipment and instruments. It was found that the most critical item is the certified reference material, the purchase or repair of which must be expedited within 125 days prior to the receipt to occur within the desired period.

  15. Ecological evaluation of proposed dredged material from St. Andrew Bay, Florida

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mayhew, H.L.; Word, J.Q.; Kohn, N.P.

    1993-10-01

    The US Army Corps of Engineers (USACE), Mobile District, requested that the Battelle/Marine Sciences Laboratory (MSL) conduct field sampling and chemical and biological testing to determine the suitability of potential dredged material for open ocean disposal. Sediment from St. Andrew Bay was chemically characterized and evaluated for biological toxicity and bioaccumulation of contaminants. The Tier III guidance for ocean disposal testing requires tests of water column effects (following dredged material disposal), deposited sediment toxicity, and bioaccumulation of contaminants from deposited sediment (dredged material). To meet these requirements, the MSL conducted suspended-particulate-phase (SPP) toxicity tests, solid-phase toxicity tests, and bioaccumulation testingmore » on sediment representing potential dredged material from Panama City Harbor. Physical and chemical characterization of sediment to support toxicity and bioaccumulation results was also conducted on both the test and reference sediments. The MSL collected sediment samples from five sites in St. Andrew Bay and one reference site near Lands End Peninsula. The five test sediments and the reference sediment were analyzed for physical and chemical sediment characteristics, SPP chemical contaminants, solid-phase toxicity, SPP toxicity, and bioaccumulation of contaminants.« less

  16. Round robin test for odour testing of migration waters.

    PubMed

    Rapp, Thomas; Günther, Herbert

    2015-04-15

    For a round robin test for EN 1420-1 (Odour assessment for organic materials in contact with drinking water) with 14 contributing laboratories from 10 European countries segments of a plastic pipe were sent to the laboratories which performed a migration test and an odour analysis of the migration waters (water that had contact with the organic material) according to the procedure described in the standard from 1999. In addition reference substances (Methyl tert-butyl ether, 1-butanol and hexanal) were investigated for their suitability to qualify the panels and the individual panellists. Methyl tert-butyl ether (MtBE) and 1-butanol proved to be suitable for this purpose, whereas hexanal showed a wide distribution of the individual odour threshold concentrations. Both possible testing options (unforced and forced choice) were performed and gave similar results. However, with respect to the qualification of the panellists and the data analysis the unforced choice procedure showed advantages. As human olfactory perception is used for the analysis, the reproducibility and the comparability between laboratories is of particular concern. For the pipe material the TON results of the different laboratories were in a range of ±1.5 dilutions based on a dilution factor of 2. This might be improved by taking the individual sensitivities of the panellists into account more strongly. Appropriate measures for the improvement of the test method appear to be the use of the proposed reference substances for the training of the panellists as well as the auditing and the selection of the panellists. The results of this round robin test are used in the revision process of the standard. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Measuring space radiation shielding effectiveness

    NASA Astrophysics Data System (ADS)

    Bahadori, Amir; Semones, Edward; Ewert, Michael; Broyan, James; Walker, Steven

    2017-09-01

    Passive radiation shielding is one strategy to mitigate the problem of space radiation exposure. While space vehicles are constructed largely of aluminum, polyethylene has been demonstrated to have superior shielding characteristics for both galactic cosmic rays and solar particle events due to the high hydrogen content. A method to calculate the shielding effectiveness of a material relative to reference material from Bragg peak measurements performed using energetic heavy charged particles is described. Using accelerated alpha particles at the National Aeronautics and Space Administration Space Radiation Laboratory at Brookhaven National Laboratory, the method is applied to sample tiles from the Heat Melt Compactor, which were created by melting material from a simulated astronaut waste stream, consisting of materials such as trash and unconsumed food. The shielding effectiveness calculated from measurements of the Heat Melt Compactor sample tiles is about 10% less than the shielding effectiveness of polyethylene. Shielding material produced from the astronaut waste stream in the form of Heat Melt Compactor tiles is therefore found to be an attractive solution for protection against space radiation.

  18. An approach to shortening the timeframe between the emergence of new compounds on the drugs market and the availability of reference standards: The microscale syntheses of nitrazolam and clonazolam for use as reference materials, utilizing polymer-supported reagents.

    PubMed

    Dowling, Geraldine; Kavanagh, Pierce V; Eckhardt, Hans-Georg; Twamley, Brendan; Hessman, Gary; McLaughlin, Gavin; O'Brien, John; Brandt, Simon D

    2018-03-15

    Nitrazolam and clonazolam are 2 designer benzodiazepines available from Internet retailers. There is growing evidence suggesting that such compounds have the potential to cause severe adverse events. Information about tolerability in humans is scarce but typically, low doses can be difficult to administer for users when handling bulk material. Variability of the active ingredient in tablet formulations can also be of a concern. Customs, toxicology and forensic laboratories are increasingly encountering designer benzodiazepines, both in tablet and powdered form. The unavailability of reference standards can impact on the ability to identify these compounds. Therefore, the need arises for exploring in-house approaches to the preparation of new psychoactive substances (NPS) that can be carried out in a timely manner. The present study was triggered when samples of clonazolam were received in powdered and tablet form at a time when reference material for this drug was commercially unavailable. Therefore, microscale syntheses of clonazolam and its deschloro analog nitrazolam were developed utilizing polymer-supported reagents starting from 2-amino-2'-chloro-5-nitrobenzophenone (clonazolam) and 2-amino-5-nitrobenzophenone (nitrazolam). The final reaction step forming the 1,2,4-triazole ring moiety was performed within a gas chromatography-mass spectrometry (GC-MS) injector. A comparison with a preparative scale synthesis of both benzodiazepine derivatives showed that microscale synthesis might be an attractive option for a forensic laboratory in terms of time and cost savings when compared with traditional methods of synthesis and when qualitative identifications are needed to direct forensic casework. The reaction by-product profiles for both the micro and the preparative scale syntheses are also presented. Copyright © 2018 John Wiley & Sons, Ltd.

  19. Statistical analyses of the background distribution of groundwater solutes, Los Alamos National Laboratory, New Mexico.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Longmire, Patrick A.; Goff, Fraser; Counce, D. A.

    2004-01-01

    Background or baseline water chemistry data and information are required to distingu ish between contaminated and non-contaminated waters for environmental investigations conducted at Los Alamos National Laboratory (referred to as the Laboratory). The term 'background' refers to natural waters discharged by springs or penetrated by wells that have not been contaminated by LANL or other municipal or industrial activities, and that are representative of groundwater discharging from their respective aquifer material. These investigations are conducted as part of the Environmental Restoration (ER) Project, Groundwater Protection Program (GWPP), Laboratory Surveillance Program, the Hydrogeologic Workplan, and the Site-Wide Environmental Impact Statement (SWEIS).more » This poster provides a comprehensive, validated database of inorganic, organic, stable isotope, and radionuclide analyses of up to 136 groundwater samples collected from 15 baseline springs and wells located in and around Los Alamos National Laboratory, New Mexico. The region considered in this investigation extends from the western edge of the Jemez Mountains eastward to the Rio Grande and from Frijoles Canyon northward to Garcia Canyon. Figure 1 shows the fifteen stations sampled for this investigation. The sampling stations and associated aquifer types are summarized in Table 1.« less

  20. Inter-laboratory comparison of elemental analysis and gas chromatography combustion isotope ratio mass spectrometry (GC-C-IRMS). Part I: delta13C measurements of selected compounds for the development of an isotopic Grob-test.

    PubMed

    Serra, F; Janeiro, A; Calderone, G; Rojas, J M Moreno; Rhodes, C; Gonthier, L A; Martin, F; Lees, M; Mosandl, A; Sewenig, S; Hener, U; Henriques, B; Ramalho, L; Reniero, F; Teixeira, A J; Guillou, C

    2007-03-01

    This study was directed towards investigating suitable compounds to be used as stable isotope reference materials for gas chromatography combustion isotope ratio mass spectrometry (GC-C-IRMS) calibration. Several compounds were selected from those used in the 'Grob-test' mixture. Oxygen- and nitrogen-containing substances were added to these compounds to allow the mixture to be used as a possible multi-isotopic calibration tool for 2H/1H, 13C/12C, 15N/14N and 18O/16O ratio determinations. In this paper we present the results of delta13C measurements performed by the consortium of the five laboratories taking part in this inter-calibration exercise. All the compounds were individually assessed for homogeneity, short-term stability and long-term stability by means of EA-IRMS, as required by the bureau communitaire de reference (BCR) Guide for Production of Certified Reference Materials. The results were compared then with the GC-C-IRMS measurements using both polar and non-polar columns, and the final mixture of selected compounds underwent a further certification exercise assessing limits of accuracy and reproducibility under specified GC-C-IRMS conditions. Copyright 2007 John Wiley & Sons, Ltd.

  1. Inter-laboratory comparison measurements of radiochemical laboratories in Slovakia.

    PubMed

    Meresová, J; Belanová, A; Vrsková, M

    2010-01-01

    The first inter-laboratory comparison organized by the radiochemistry laboratory of Water Research Institute (WRI) in Bratislava was carried out in 1993 and since then is it realized on an annual basis and about 10 radiochemical laboratories from all over Slovakia are participating. The gross alpha and gross beta activities, and the activity concentrations of (222)Rn, tritium, and (226)Ra, and U(nat) concentration in synthetic water samples are compared. The distributed samples are covering the concentration range prevailing in potable and surface waters and are prepared by dilution of certified reference materials. Over the course of the years 1993-2008, we observed the improvement in the quality of results for most of the laboratories. However, the success rate of the gross alpha determination activity is not improving as much as the other parameters. Copyright 2009 Elsevier Ltd. All rights reserved.

  2. [Analysis of productivity, quality and cost of first grade laboratories: blood biometry].

    PubMed

    Avila, L; Hernández, P; Cruz, A; Zurita, B; Terres, A M; Cruz, C

    1999-04-01

    Assessment of productivity, quality and production costs and determination of the efficiency of top grade clinical laboratories in Mexico. Ten laboratories were selected from among the total number (52) existing in Mexico City, and the Donabedian model of structure, process and results were applied. Blood count was selected as a tracer. The principal problems found were: inadequate distribution of trained human resources, poor glass material, inadequate analytic process and low productivity. These factors are reflected in the unit costs, which exceed reference laboratory costs by 200%. Only 50% of the laboratories analyzed generate reliable results. Only 20% of the laboratories studied operate efficiently. To solve the problems identified requires integral strategies at different levels. A specific recomendation for the improvement of quality and productivity is an assessment of the cost/benefit of creating a central laboratory and using the remaining sites exclusively for the collection of samples.

  3. Interlaboratory Study Characterizing a Yeast Performance Standard for Benchmarking LC-MS Platform Performance*

    PubMed Central

    Paulovich, Amanda G.; Billheimer, Dean; Ham, Amy-Joan L.; Vega-Montoto, Lorenzo; Rudnick, Paul A.; Tabb, David L.; Wang, Pei; Blackman, Ronald K.; Bunk, David M.; Cardasis, Helene L.; Clauser, Karl R.; Kinsinger, Christopher R.; Schilling, Birgit; Tegeler, Tony J.; Variyath, Asokan Mulayath; Wang, Mu; Whiteaker, Jeffrey R.; Zimmerman, Lisa J.; Fenyo, David; Carr, Steven A.; Fisher, Susan J.; Gibson, Bradford W.; Mesri, Mehdi; Neubert, Thomas A.; Regnier, Fred E.; Rodriguez, Henry; Spiegelman, Cliff; Stein, Stephen E.; Tempst, Paul; Liebler, Daniel C.

    2010-01-01

    Optimal performance of LC-MS/MS platforms is critical to generating high quality proteomics data. Although individual laboratories have developed quality control samples, there is no widely available performance standard of biological complexity (and associated reference data sets) for benchmarking of platform performance for analysis of complex biological proteomes across different laboratories in the community. Individual preparations of the yeast Saccharomyces cerevisiae proteome have been used extensively by laboratories in the proteomics community to characterize LC-MS platform performance. The yeast proteome is uniquely attractive as a performance standard because it is the most extensively characterized complex biological proteome and the only one associated with several large scale studies estimating the abundance of all detectable proteins. In this study, we describe a standard operating protocol for large scale production of the yeast performance standard and offer aliquots to the community through the National Institute of Standards and Technology where the yeast proteome is under development as a certified reference material to meet the long term needs of the community. Using a series of metrics that characterize LC-MS performance, we provide a reference data set demonstrating typical performance of commonly used ion trap instrument platforms in expert laboratories; the results provide a basis for laboratories to benchmark their own performance, to improve upon current methods, and to evaluate new technologies. Additionally, we demonstrate how the yeast reference, spiked with human proteins, can be used to benchmark the power of proteomics platforms for detection of differentially expressed proteins at different levels of concentration in a complex matrix, thereby providing a metric to evaluate and minimize preanalytical and analytical variation in comparative proteomics experiments. PMID:19858499

  4. A guide for the laboratory information management system (LIMS) for light stable isotopes--Versions 7 and 8

    USGS Publications Warehouse

    Coplen, Tyler B.

    2000-01-01

    The reliability and accuracy of isotopic data can be improved by utilizing database software to (i) store information about samples, (ii) store the results of mass spectrometric isotope-ratio analyses of samples, (iii) calculate analytical results using standardized algorithms stored in a database, (iv) normalize stable isotopic data to international scales using isotopic reference materials, and (v) generate multi-sheet paper templates for convenient sample loading of automated mass-spectrometer sample preparation manifolds. Such a database program, the Laboratory Information Management System (LIMS) for Light Stable Isotopes, is presented herein. Major benefits of this system include (i) a dramatic improvement in quality assurance, (ii) an increase in laboratory efficiency, (iii) a reduction in workload due to the elimination or reduction of retyping of data by laboratory personnel, and (iv) a decrease in errors in data reported to sample submitters. Such a database provides a complete record of when and how often laboratory reference materials have been analyzed and provides a record of what correction factors have been used through time. It provides an audit trail for laboratories. LIMS for Light Stable Isotopes is available for both Microsoft Office 97 Professional and Microsoft Office 2000 Professional as versions 7 and 8, respectively. Both source code (mdb file) and precompiled executable files (mde) are available. Numerous improvements have been made for continuous flow isotopic analysis in this version (specifically 7.13 for Microsoft Access 97 and 8.13 for Microsoft Access 2000). It is much easier to import isotopic results from Finnigan ISODAT worksheets, even worksheets on which corrections for amount of sample (linearity corrections) have been added. The capability to determine blank corrections using isotope mass balance from analyses of elemental analyzer samples has been added. It is now possible to calculate and apply drift corrections to isotopic data based on the time of day of analysis. Whereas Finnigan ISODAT software is confined to using only a single peak for calculating delta values, LIMS now enables one to use the mean of two or more reference injections during a continuous flow analysis to calculate delta values. This is useful with Finnigan?s GasBench II online sample preparation system. Concentrations of carbon, nitrogen, and sulfur can be calculated based one or more isotopic reference materials analyzed with a group of samples. Both sample data and isotopic analysis data can now be exported to Excel files. A calculator for determining the amount of sample needed for isotopic analysis based on a previous amount of sample and continuous flow area is now an integral part of LIMS for Light Stable Isotopes. LIMS for Light Stable Isotopes can now assign an error code to Finnigan elemental analyzer analyses in which one of the electrometers has saturated due to analysis of too much sample material, giving rise to incorrect isotopic abundances. Information on downloading this report and downloading code and databases is provided at the Internet addresses: http://water.usgs.gov/software/geochemical.html or http://www.geogr.uni-jena.de/software/geochemical.html in the Eastern Hemisphere.

  5. HMPT: Hazardous Waste Transportation Live 27928, Test 27929

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simpson, Lewis Edward

    2016-03-17

    HMPT: Hazardous Waste Transportation (Live 27928, suggested one time and associated Test 27929, required initially and every 36 months) addresses the Department of Transportation (DOT) function-specific training requirements of the hazardous materials packagings and transportation (HMPT) Los Alamos National Laboratory (LANL) lab-wide training. This course addresses the requirements of the DOT that are unique to hazardous waste shipments. Appendix B provides the Title 40 Code of Federal Regulations (CFR) reference material needed for this course.

  6. Utility of NIST Whole-Genome Reference Materials for the Technical Validation of a Multigene Next-Generation Sequencing Test.

    PubMed

    Shum, Bennett O V; Henner, Ilya; Belluoccio, Daniele; Hinchcliffe, Marcus J

    2017-07-01

    The sensitivity and specificity of next-generation sequencing laboratory developed tests (LDTs) are typically determined by an analyte-specific approach. Analyte-specific validations use disease-specific controls to assess an LDT's ability to detect known pathogenic variants. Alternatively, a methods-based approach can be used for LDT technical validations. Methods-focused validations do not use disease-specific controls but use benchmark reference DNA that contains known variants (benign, variants of unknown significance, and pathogenic) to assess variant calling accuracy of a next-generation sequencing workflow. Recently, four whole-genome reference materials (RMs) from the National Institute of Standards and Technology (NIST) were released to standardize methods-based validations of next-generation sequencing panels across laboratories. We provide a practical method for using NIST RMs to validate multigene panels. We analyzed the utility of RMs in validating a novel newborn screening test that targets 70 genes, called NEO1. Despite the NIST RM variant truth set originating from multiple sequencing platforms, replicates, and library types, we discovered a 5.2% false-negative variant detection rate in the RM truth set genes that were assessed in our validation. We developed a strategy using complementary non-RM controls to demonstrate 99.6% sensitivity of the NEO1 test in detecting variants. Our findings have implications for laboratories or proficiency testing organizations using whole-genome NIST RMs for testing. Copyright © 2017 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  7. NBL CRM 112-A: A new certified isotopic composition

    NASA Astrophysics Data System (ADS)

    Thomas, R. B.; Essex, R. M.; Mason, P.

    2007-12-01

    NBL CRM 112-A Uranium Metal Assay Standard is commonly used as a natural uranium isotopic reference material within the earth science mass spectrometry community. The metal is from the same parent material as NBS SRM 960, the uranyl nitrate solution, CRM 145, and the high-purity uranyl nitrate solution CRM 145-B. Because CRM 112-A has not yet been certified for isotopic composition, it has been assumed that this material has a natural 235U/238U (0.0072527), and the δ234U has been determined by measurement (e.g. -37.1‰; Cheng et al., 2000). These values have been widely used to calibrate the concentration of spikes and standards, and to correct measurements for instrument or mass bias. New, preliminary, isotopic measurements on CRM 145 and CRM 112-A performed at New Brunswick Laboratory suggest that these reference materials have a slightly lower 235U/238U and δ234U than have been commonly used. If this is the case, then data using the accepted values may be slightly biased. The significance of this bias will depend on the uncertainty of the measurement, how the CRM 112-A data is used to correct measurement data, the cited values that were used to correct the data, and the final certified values of the CRM. This fall, New Brunswick Laboratory is certifying the isotopic composition of the CRM 112-A metal using high precision thermal ionization mass spectrometry techniques. Upon completion of certification, the new CRM 112- A standard with certified isotopic ratios will provide the earth science community with a well characterized and traceable reference for calibrating and correcting their mass spectrometry measurement systems.

  8. An Experimental Weight Function Method for Stress Intensity Factor Calibration.

    DTIC Science & Technology

    1980-04-01

    in accuracy to the ones obtained by Macha (Reference 10) for the laser interferometry technique. The values of KI from the interpolating polynomial...Measurement. Air Force Material Laboratories, AFML-TR-74-75, July 1974. 10. D. E. Macha , W. N. Sharpe Jr., and A. F. Grandt Jr., A Laser Interferometry

  9. Guide for Teaching Chemistry-Physics Combined 1-2, 3-4 (PSSC - CHEMS).

    ERIC Educational Resources Information Center

    Millstone, H. George

    This guide is written for a combined physics-chemistry course taught over a two-year period. The subject matter contains the major ideas in Chemical Education Materials Study (CHEMS) Chemistry and Physical Science Study Committee (PSSC) Physics. The guide includes discussion of text references, laboratory experiments, films, testing and evaluation…

  10. ASSESSMENT OF STANDARD REFERENCE COMPOUNDS FOR COMPARATIVE STUDIES USING THE SALMONELLA TYPHIMURIUM MUTAGENICITY ASSAY: I. WITHOUT EXOGENOUS ACTIVATION

    EPA Science Inventory

    Finney (1978) described a bioassay as an experiment for estimating the nature, constitution, or potency of a material by means of the eaction that follows its application to living matter. n this paper, two independent laboratories tested 10 known Salmonella mutagens in order to ...

  11. Course Manual for X-Ray Applications (GS-463).

    ERIC Educational Resources Information Center

    Oregon State Univ., Corvallis. Dept. of General Science.

    This publication is the third of three sequential course manuals for instructors in X-Ray science and engineering developed at Oregon State University. It consists of outlines of thirteen lectures, and six laboratory exercises with problems and three examinations. Also included is a list of references, equipment, and material. The purposes,…

  12. Reduced detrital resources limit Pycnopsyche gentilis (Trichoptera: Limnephilidae) production and growth

    Treesearch

    Susan L. Eggert; J. Bruce Wallace

    2003-01-01

    Leaf inputs in temperate forest streams may limit caddisfly production because leaf detritus serves both as a food and case-material resource. We estimated Pycnopsyche gentilis produdion in a stream experimentally decoupled fmm its riparian habitat and a reference stream for 8 y in the southern Appalachians. We also examined laboratory survivorship,...

  13. Course Manual for X-Ray Measurements (GS-462).

    ERIC Educational Resources Information Center

    Oregon State Univ., Corvallis. Dept. of General Science.

    This is the second of three sequential course manuals for instructors in X-Ray science and engineering developed at Oregon State University. It consists of outlines for fourteen lectures and eight laboratory exercises with problems and two examinations. Also included is a list of references, equipment, and materials. The purposes, teaching aids,…

  14. Differences in serum thyroglobulin measurements by 3 commercial immunoradiometric assay kits and laboratory standardization using Certified Reference Material 457 (CRM-457).

    PubMed

    Lee, Ji In; Kim, Ji Young; Choi, Joon Young; Kim, Hee Kyung; Jang, Hye Won; Hur, Kyu Yeon; Kim, Jae Hyeon; Kim, Kwang-Won; Chung, Jae Hoon; Kim, Sun Wook

    2010-09-01

    Serum thyroglobulin (Tg) is essential in the follow-up of patients with differentiated thyroid carcinoma (DTC). However, interchangeability and standardization between Tg assays have not yet been achieved, even with the development of an international Tg standard (Certified Reference Material 457 [CRM-457]). Serum Tg from 30 DTC patients and serially diluted CRM-457 were measured using 3 different immunoradiometric assays (IRMA-1, IRMA-2, IRMA-3). The intraclass correlation coefficient (ICC) method was used to describe the concordance of each IRMA to CRM-457. The serum Tg measured by 3 different IRMAs correlated well (r > .85, p < .0001), but clinically relevant discrepancies were found in 13.3% of patients. IRMA-3, which claims to be standardized to CRM-457, showed the best ICC (p(1) = .98) for the CRM-457. Hospitals caring for patients with DTC should either set their own cutoffs for IRMAs for Tg based on their patient pools, or adopt IRMAs standardized to CRM-457 and calibrate their laboratory using CRM-457.

  15. Reference materials for molecular diagnostics: Current achievements and future strategies.

    PubMed

    Jing, Rongrong; Wang, Huimin; Ju, Shaoqing; Cui, Ming

    2018-06-01

    Molecular diagnoses have become more widespread in many areas of laboratory medicine where qualitative or quantitative approaches are used to detect nucleic acids. The increasing number of assay methods and the targets for molecular diagnostics contribute to variability in the test results among clinical laboratories. Thus, reference materials (RMs) are required to enhance the comparability of results. This review focuses on the definition of RMs as well as the production and characteristics of higher order RMs from different organizations and their future strategies. We describe the recent progress in RMs, including the definition of RMs by the Joint Committee for Guides in Metrology, as well as the production and characteristics of higher order RMs by international official bodies. There is an urgent need for RMs in nucleic acid testing, especially higher order RMs. To advance the harmonization and standardization of clinical nucleic acid detection, cooperation between the above organizations is proposed and different approaches to higher order RMs development are also needed. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  16. Cross-platform comparison of nucleic acid hybridization: toward quantitative reference standards.

    PubMed

    Halvorsen, Ken; Agris, Paul F

    2014-11-15

    Measuring interactions between biological molecules is vitally important to both basic and applied research as well as development of pharmaceuticals. Although a wide and growing range of techniques is available to measure various kinetic and thermodynamic properties of interacting biomolecules, it can be difficult to compare data across techniques of different laboratories and personnel or even across different instruments using the same technique. Here we evaluate relevant biological interactions based on complementary DNA and RNA oligonucleotides that could be used as reference standards for many experimental systems. We measured thermodynamics of duplex formation using isothermal titration calorimetry, differential scanning calorimetry, and ultraviolet-visible (UV-vis) monitored denaturation/renaturation. These standards can be used to validate results, compare data from disparate techniques, act as a teaching tool for laboratory classes, or potentially to calibrate instruments. The RNA and DNA standards have many attractive features, including low cost, high purity, easily measurable concentrations, and minimal handling concerns, making them ideal for use as a reference material. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Cross-platform comparison of nucleic acid hybridization: toward quantitative reference standardsa

    PubMed Central

    Halvorsen, Ken; Agris, Paul F.

    2014-01-01

    Measuring interactions between biological molecules is vitally important to both basic and applied research, as well as development of pharmaceuticals. While a wide and growing range of techniques are available to measure various kinetic and thermodynamic properties of interacting biomolecules, it can be difficult to compare data across techniques of different laboratories and personnel, or even across different instruments using the same technique. Here we evaluate relevant biological interactions based on complementary DNA and RNA oligonucleotides that could be used as reference standards for many experimental systems. We measured thermodynamics of duplex formation using Isothermal Titration Calorimetry, Differential Scanning Calorimetry, and UV-Vis monitored denaturation/renaturation. These standards can be used to validate results, compare data from disparate techniques, act as a teaching tool for laboratory classes, or potentially to calibrate instruments. The RNA and DNA standards have many attractive features including low cost, high purity, easily measureable concentrations, and minimal handling concerns, making them ideal for use as a reference material. PMID:25124363

  18. Certified reference materials (GBW09170 and 09171) of creatinine in human serum.

    PubMed

    Dai, Xinhua; Fang, Xiang; Shao, Mingwu; Li, Ming; Huang, Zejian; Li, Hongmei; Jiang, You; Song, Dewei; He, Yajuan

    2011-02-15

    Creatinine is the most widely used clinical marker for assessing renal function. Concentrations of creatinine in human serum need to be carefully checked in order to ensure accurate diagnosis of renal function. Therefore, development of certified reference materials (CRMs) of creatinine in serum is of increasing importance. In this study, two new CRMs (Nos. GBW09170 and 09171) for creatinine in human serum have been developed. They were prepared with mixtures of several dozens of healthy people's and kidney disease patient's serum, respectively. The certified values of 8.10, 34.1 mg/kg for these two CRMs have been assigned by liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) method which was validated by using standard reference material (SRM) of SRM909b (a reference material obtained from National Institute of Standards and Technology, NIST). The expanded uncertainties of certified values for low and high concentrations were estimated to be 1.2 and 1.1%, respectively. The certified values were further confirmed by an international intercomparison for the determination of creatinine in human serum (Consultative Committee for Amount of Substance, CCQM) of K80 (CCQM-K80). These new CRMs of creatinine in human serum pool are totally native without additional creatinine spiked for enrichment. These new CRMs are capable of validating routine clinical methods for ensuring accuracy, reliability and comparability of analytical results from different clinical laboratories. They can also be used for instrument validation, development of secondary reference materials, and evaluating the accuracy of high order clinical methods for the determination of creatinine in human serum. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Production of highly-enriched 134Ba for a reference material for isotope dilution mass spectrometry measurements

    DOE PAGES

    Horkley, J. J.; Carney, K. P.; Gantz, E. M.; ...

    2015-03-17

    Isotope dilution mass spectrometry (IDMS) is an analytical technique capable of providing accurate and precise quantitation of trace isotope abundance and assay providing measurement uncertainties below 1 %. To achieve these low uncertainties, the IDMS method ideally utilizes chemically pure “spike” solutions that consist of a single highly enriched isotope that is well-characterized relating to the abundance of companion isotopes and concentration in solution. To address a current demand for accurate 137Cs/137Ba ratio measurements for “age” determination of radioactive 137Cs sources, Idaho National Laboratory (INL) is producing enriched 134Ba isotopes that are tobe used for IDMS spikes to accurately determinemore » 137Ba accumulation from the decay of 137Cs. The final objective of this work it to provide a homogenous set of reference materials that the National Institute of Standards and Technology can certify as standard reference materials used for IDMS. The process that was developed at INL for the separation and isolation of Ba isotopes, chemical purification of the isotopes in solution, and the encapsulation of the materials will be described.« less

  20. An analysis of reference laboratory (send out) testing: an 8-year experience in a large academic medical center.

    PubMed

    MacMillan, Donna; Lewandrowski, Elizabeth; Lewandrowski, Kent

    2004-01-01

    Utilization of outside reference laboratories for selected laboratory testing is common in the United States. However, relatively little data exist in the literature describing the scope and impact of these services. In this study, we reviewed use of reference laboratory testing at the Massachusetts General Hospital, a large urban academic medical center in Boston, Massachusetts. A retrospective review of hospital and laboratory administrative records over an 8-year period from fiscal years (FY) 1995-2002. Over the 8 years studied, reference laboratory expenses increased 4.2-fold and totaled 12.4% of the total laboratory budget in FY 2002. Total reference laboratory test volume increased 4-fold to 68,328 tests in FY 2002 but represented only 1.06% of the total test volume in the hospital. The menu of reference laboratory tests comprised 946 tests (65.7% of the hospital test menu) compared to 494 (34.3%) of tests performed in house. The average unit cost of reference laboratory tests was essentially unchanged but was approximately 13 times greater than the average unit cost in the hospital laboratory. Much of the growth in reference laboratory cost can be attributed to the addition of new molecular, genetic, and microbiological assays. Four of the top 10 tests with the highest total cost in 2002 were molecular diagnostic tests that were recently added to the test menu. Reference laboratory testing comprises a major component of hospital clinical laboratory services. Although send out tests represent a small percentage of the total test volume, these services account for the majority of the hospital laboratory test menu and a disproportionate percentage of laboratory costs.

  1. Multilaboratory Validation of First Action Method 2016.04 for Determination of Four Arsenic Species in Fruit Juice by High-Performance Liquid Chromatography-Inductively Coupled Plasma-Mass Spectrometry.

    PubMed

    Kubachka, Kevin; Heitkemper, Douglas T; Conklin, Sean

    2017-07-01

    Before being designated AOAC First Action Official MethodSM 2016.04, the U.S. Food and Drug Administration's method, EAM 4.10 High Performance Liquid Chromatography-Inductively Coupled Plasma-Mass Spectrometric Determination of Four Arsenic Species in Fruit Juice, underwent both a single-laboratory validation and a multilaboratory validation (MLV) study. Three federal and five state regulatory laboratories participated in the MLV study, which is the primary focus of this manuscript. The method was validated for inorganic arsenic (iAs) measured as the sum of the two iAs species arsenite [As(III)] and arsenate [As(V)], dimethylarsinic acid (DMA), and monomethylarsonic acid (MMA) by analyses of 13 juice samples, including three apple juice, three apple juice concentrate, four grape juice, and three pear juice samples. In addition, two water Standard Reference Materials (SRMs) were analyzed. The method LODs and LOQs obtained among the eight laboratories were approximately 0.3 and 2 ng/g, respectively, for each of the analytes and were adequate for the intended purpose of the method. Each laboratory analyzed method blanks, fortified method blanks, reference materials, triplicate portions of each juice sample, and duplicate fortified juice samples (one for each matrix type) at three fortification levels. In general, repeatability and reproducibility of the method was ≤15% RSD for each species present at a concentration >LOQ. The average recovery of fortified analytes for all laboratories ranged from 98 to 104% iAs, DMA, and MMA for all four juice sample matrixes. The average iAs results for SRMs 1640a and 1643e agreed within the range of 96-98% of certified values for total arsenic.

  2. Trueness verification of actual creatinine assays in the European market demonstrates a disappointing variability that needs substantial improvement. An international study in the framework of the EC4 creatinine standardization working group.

    PubMed

    Delanghe, Joris R; Cobbaert, Christa; Galteau, Marie-Madeleine; Harmoinen, Aimo; Jansen, Rob; Kruse, Rolf; Laitinen, Päivi; Thienpont, Linda M; Wuyts, Birgitte; Weykamp, Cas; Panteghini, Mauro

    2008-01-01

    The European In Vitro Diagnostics (IVD) directive requires traceability to reference methods and materials of analytes. It is a task of the profession to verify the trueness of results and IVD compatibility. The results of a trueness verification study by the European Communities Confederation of Clinical Chemistry (EC4) working group on creatinine standardization are described, in which 189 European laboratories analyzed serum creatinine in a commutable serum-based material, using analytical systems from seven companies. Values were targeted using isotope dilution gas chromatography/mass spectrometry. Results were tested on their compliance to a set of three criteria: trueness, i.e., no significant bias relative to the target value, between-laboratory variation and within-laboratory variation relative to the maximum allowable error. For the lower and intermediate level, values differed significantly from the target value in the Jaffe and the dry chemistry methods. At the high level, dry chemistry yielded higher results. Between-laboratory coefficients of variation ranged from 4.37% to 8.74%. Total error budget was mainly consumed by the bias. Non-compensated Jaffe methods largely exceeded the total error budget. Best results were obtained for the enzymatic method. The dry chemistry method consumed a large part of its error budget due to calibration bias. Despite the European IVD directive and the growing needs for creatinine standardization, an unacceptable inter-laboratory variation was observed, which was mainly due to calibration differences. The calibration variation has major clinical consequences, in particular in pediatrics, where reference ranges for serum and plasma creatinine are low, and in the estimation of glomerular filtration rate.

  3. Determination of perfluorinated alkyl acid concentrations in biological standard reference materials.

    PubMed

    Reiner, Jessica L; O'Connell, Steven G; Butt, Craig M; Mabury, Scott A; Small, Jeff M; De Silva, Amila O; Muir, Derek C G; Delinsky, Amy D; Strynar, Mark J; Lindstrom, Andrew B; Reagen, William K; Malinsky, Michelle; Schäfer, Sandra; Kwadijk, Christiaan J A F; Schantz, Michele M; Keller, Jennifer M

    2012-11-01

    Standard reference materials (SRMs) are homogeneous, well-characterized materials used to validate measurements and improve the quality of analytical data. The National Institute of Standards and Technology (NIST) has a wide range of SRMs that have mass fraction values assigned for legacy pollutants. These SRMs can also serve as test materials for method development, method validation, and measurement for contaminants of emerging concern. Because inter-laboratory comparison studies have revealed substantial variability of measurements of perfluoroalkyl acids (PFAAs), future analytical measurements will benefit from determination of consensus values for PFAAs in SRMs to provide a means to demonstrate method-specific performance. To that end, NIST, in collaboration with other groups, has been measuring concentrations of PFAAs in a variety of SRMs. Here we report levels of PFAAs and perfluorooctane sulfonamide (PFOSA) determined in four biological SRMs: fish tissue (SRM 1946 Lake Superior Fish Tissue, SRM 1947 Lake Michigan Fish Tissue), bovine liver (SRM 1577c), and mussel tissue (SRM 2974a). We also report concentrations for three in-house quality-control materials: beluga whale liver, pygmy sperm whale liver, and white-sided dolphin liver. Measurements in SRMs show an array of PFAAs, with perfluorooctane sulfonate (PFOS) being the most frequently detected. Reference and information values are reported for PFAAs measured in these biological SRMs.

  4. Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China.

    PubMed

    Xia, Liangyu; Chen, Ming; Liu, Min; Tao, Zhihua; Li, Shijun; Wang, Liang; Cheng, Xinqi; Qin, Xuzhen; Han, Jianhua; Li, Pengchang; Hou, Li'an; Yu, Songlin; Ichihara, Kiyoshi; Qiu, Ling

    2016-03-01

    A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box-Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China.

  5. Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China

    PubMed Central

    Xia, Liangyu; Chen, Ming; Liu, Min; Tao, Zhihua; Li, Shijun; Wang, Liang; Cheng, Xinqi; Qin, Xuzhen; Han, Jianhua; Li, Pengchang; Hou, Li’an; Yu, Songlin; Ichihara, Kiyoshi; Qiu, Ling

    2016-01-01

    Abstract A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box–Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China. PMID:26945390

  6. Current Practices of Measuring and Reference Range Reporting of Free and Total Testosterone in the United States.

    PubMed

    Le, Margaret; Flores, David; May, Danica; Gourley, Eric; Nangia, Ajay K

    2016-05-01

    The evaluation and management of male hypogonadism should be based on symptoms and on serum testosterone levels. Diagnostically this relies on accurate testing and reference values. Our objective was to define the distribution of reference values and assays for free and total testosterone by clinical laboratories in the United States. Upper and lower reference values, assay methodology and source of published reference ranges were obtained from laboratories across the country. A standardized survey was reviewed with laboratory staff via telephone. Descriptive statistics were used to tabulate results. We surveyed a total of 120 laboratories in 47 states. Total testosterone was measured in house at 73% of laboratories. At the remaining laboratories studies were sent to larger centralized reference facilities. The mean ± SD lower reference value of total testosterone was 231 ± 46 ng/dl (range 160 to 300) and the mean upper limit was 850 ± 141 ng/dl (range 726 to 1,130). Only 9% of laboratories where in-house total testosterone testing was performed created a reference range unique to their region. Others validated the instrument recommended reference values in a small number of internal test samples. For free testosterone 82% of laboratories sent testing to larger centralized reference laboratories where equilibrium dialysis and/or liquid chromatography with mass spectrometry was done. The remaining laboratories used published algorithms to calculate serum free testosterone. Reference ranges for testosterone assays vary significantly among laboratories. The ranges are predominantly defined by limited population studies of men with unknown medical and reproductive histories. These poorly defined and variable reference values, especially the lower limit, affect how clinicians determine treatment. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  7. A Thermal Stability Test for Primary Explosive Stab Sensitizers: Study of the Thermal and Hydrolytic Stability of 2-Picryl-5-Nitrotetrazole,

    DTIC Science & Technology

    1984-02-01

    have been described previously (2]. The actual batch used was designated Batch D and was identical to that referred to as Batch C in Reference [2...Tetrazene was type RD1357 prepared at Materials Research Laboratories. The batch used was designated Batch 10/83(A). Lead Azide was type RD1343 and was...Preparation of Experimental Detonators Eperimental detonators were prepared in mild steel tubes, 6 mm o.d., 3.2 mm i.d., length 6 mm, prepared from

  8. New Brunswick Laboratory: Progress report, October 1987--September 1988

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    NBL has been tasked by the DOE Office of Safeguards and Security, Defense Programs (OSS/DP) to assure the application of accurate and reliable measurement technology for the safeguarding of special nuclear materials. NBL is fulfilling its mission responsibilities by identifying and addressing the measurement and measurement-related needs of the nuclear material safeguards community. These responsibilities are being addressed by activities in the following program areas: (1) reference and calibration materials, (2) measurement development, (3) measurement services, (4) measurement evaluation, (5) safeguards assessment, and (6) site-specific assistance. Highlights of each of these programs areas are provided in this summary.

  9. Two new organic reference materials for δ13C and δ15N measurements and a new value for the δ13C of NBS 22 oil

    USGS Publications Warehouse

    Qi, Haiping; Coplen, Tyler B.; Geilmann, Heike; Brand, Willi A.; Böhlke, J.K.

    2003-01-01

    Analytical grade L-glutamic acid is chemically stable and has a C/N mole ratio of 5, which is close to that of many of natural biological materials, such as blood and animal tissue. Two L-glutamic acid reference materials with substantially different 13C and 15N abundances have been prepared for use as organic reference materials for C and N isotopic measurements. USGS40 is analytical grade L-glutamic acid and has a δ13C value of −26.24‰ relative to VPDB and a δ15N value of −4.52‰ relative to N2 in air. USGS41 was prepared by dissolving analytical grade L-glutamic acid with L-glutamic acid enriched in 13C and 15N. USGS41 has a δ13C value of +37.76‰ and a δ15N value of +47.57‰. The δ13C and δ15N values of both materials were measured against the international reference materials NBS 19 calcium carbonate (δ13C = +1.95‰), L-SVEC lithium carbonate (δ13C = −46.48‰), IAEA-N-1 ammonium sulfate (δ15N = 0.43‰), and USGS32 potassium nitrate (δ15N = 180‰) by on-line combustion continuous-flow and off-line dual-inlet isotope-ratio mass spectrometry. Both USGS40 and USGS41 are isotopically homogeneous; reproducibility of δ13C is better than 0.13‰, and that of δ15N is better than 0.13‰ in 100-μg amounts. These two isotopic reference materials can be used for (i) calibrating local laboratory reference materials, and (ii) quantifying drift with time, mass-dependent fractionations, and isotope-ratio-scale contraction in the isotopic analysis of various biological materials. Isotopic results presented in this paper yield a δ13C value for NBS 22 oil of −29.91‰, in contrast to the commonly accepted value of −29.78‰ for which off-line blank corrections probably have not been quantified satisfactorily.

  10. The processing and collaborative assay of a reference endotoxin.

    PubMed

    Hochstein, H D; Mills, D F; Outschoorn, A S; Rastogi, S C

    1983-10-01

    A preparation of Escherichia coli bacterial endotoxin, the latest of successive lots drawn from bulk material which has been studied in laboratory tests and in animals and humans for suitability as a reference endotoxin, has been filled and lyophilized in a large number of vials. Details of its characterization, including stability studies, are given. A collaborative assay was conducted by 14 laboratories using gelation end-points with Limulus amebocyte lysates. Approximate continuity of the unit of potency with the existing national unit was achieved. The lot was made from the single final bulk but had to be freeze-dried in five sublimators. An assessment was therefore made for possible heterogeneity. The results indicate that the lot can be used as a large homogeneous quantity. The advantages of using it widely as a standard for endotoxins are discussed.

  11. Development of traceable measurement of the diffuse optical properties of solid reference standards for biomedical optics at National Institute of Standards and Technology.

    PubMed

    Lemaillet, Paul; Bouchard, Jean-Pierre; Allen, David W

    2015-07-01

    The development of a national reference instrument dedicated to the measurement of the scattering and absorption properties of solid tissue-mimicking phantoms used as reference standards is presented. The optical properties of the phantoms are measured with a double-integrating sphere setup in the steady-state domain, coupled with an inversion routine of the adding-doubling procedure that allows for the computation of the uncertainty budget for the measurements. The results are compared to the phantom manufacturer's values obtained by a time-resolved approach. The results suggest that the agreement between these two independent methods is within the estimated uncertainties. This new reference instrument will provide optical biomedical research laboratories with reference values for absolute diffuse optical properties of phantom materials.

  12. Survey material choices in haematology EQA: a confounding factor in automated counting performance assessment.

    PubMed

    De la Salle, Barbara

    2017-02-15

    The complete blood count (CBC) is one of the most frequently requested tests in laboratory medicine, performed in a range of healthcare situations. The provision of an ideal assay material for external quality assessment is confounded by the fragility of the cellular components of blood, the lack of commutability of stabilised whole blood material and the lack of certified reference materials and methods to which CBC results can be traced. The choice of assay material between fresh blood, extended life assay material and fully stabilised, commercially prepared, whole blood material depends upon the scope and objectives of the EQA scheme. The introduction of new technologies in blood counting and the wider clinical application of parameters from the extended CBC will bring additional challenges for the EQA provider.

  13. A candidate reference method for serum potassium measurement by inductively coupled plasma mass spectrometry.

    PubMed

    Yan, Ying; Han, Bingqing; Zeng, Jie; Zhou, Weiyan; Zhang, Tianjiao; Zhang, Jiangtao; Chen, Wenxiang; Zhang, Chuanbao

    2017-08-28

    Potassium is an important serum ion that is frequently assayed in clinical laboratories. Quality assurance requires reference methods; thus, the establishment of a candidate reference method for serum potassium measurements is important. An inductively coupled plasma mass spectrometry (ICP-MS) method was developed. Serum samples were gravimetrically spiked with an aluminum internal standard, digested with 69% ultrapure nitric acid, and diluted to the required concentration. The 39K/27Al ratios were measured by ICP-MS in hydrogen mode. The method was calibrated using 5% nitric acid matrix calibrators, and the calibration function was established using the bracketing method. The correlation coefficients between the measured 39K/27Al ratios and the analyte concentration ratios were >0.9999. The coefficients of variation were 0.40%, 0.68%, and 0.22% for the three serum samples, and the analytical recovery was 99.8%. The accuracy of the measurement was also verified by measuring certified reference materials, SRM909b and SRM956b. Comparison with the ion selective electrode routine method and international inter-laboratory comparisons gave satisfied results. The new ICP-MS method is specific, precise, simple, and low-cost, and it may be used as a candidate reference method for standardizing serum potassium measurements.

  14. The WHO/PEPFAR collaboration to prepare an operations manual for HIV prevention, care, and treatment at primary health centers in high-prevalence, resource-constrained settings: defining laboratory services.

    PubMed

    Spira, Thomas; Lindegren, Mary Lou; Ferris, Robert; Habiyambere, Vincent; Ellerbrock, Tedd

    2009-06-01

    The expansion of HIV/AIDS care and treatment in resource-constrained countries, especially in sub-Saharan Africa, has generally developed in a top-down manner. Further expansion will involve primary health centers where human and other resources are limited. This article describes the World Health Organization/President's Emergency Plan for AIDS Relief collaboration formed to help scale up HIV services in primary health centers in high-prevalence, resource-constrained settings. It reviews the contents of the Operations Manual developed, with emphasis on the Laboratory Services chapter, which discusses essential laboratory services, both at the center and the district hospital level, laboratory safety, laboratory testing, specimen transport, how to set up a laboratory, human resources, equipment maintenance, training materials, and references. The chapter provides specific information on essential tests and generic job aids for them. It also includes annexes containing a list of laboratory supplies for the health center and sample forms.

  15. Commutability of food microbiology proficiency testing samples.

    PubMed

    Abdelmassih, M; Polet, M; Goffaux, M-J; Planchon, V; Dierick, K; Mahillon, J

    2014-03-01

    Food microbiology proficiency testing (PT) is a useful tool to assess the analytical performances among laboratories. PT items should be close to routine samples to accurately evaluate the acceptability of the methods. However, most PT providers distribute exclusively artificial samples such as reference materials or irradiated foods. This raises the issue of the suitability of these samples because the equivalence-or 'commutability'-between results obtained on artificial vs. authentic food samples has not been demonstrated. In the clinical field, the use of noncommutable PT samples has led to erroneous evaluation of the performances when different analytical methods were used. This study aimed to provide a first assessment of the commutability of samples distributed in food microbiology PT. REQUASUD and IPH organized 13 food microbiology PTs including 10-28 participants. Three types of PT items were used: genuine food samples, sterile food samples and reference materials. The commutability of the artificial samples (reference material or sterile samples) was assessed by plotting the distribution of the results on natural and artificial PT samples. This comparison highlighted matrix-correlated issues when nonfood matrices, such as reference materials, were used. Artificially inoculated food samples, on the other hand, raised only isolated commutability issues. In the organization of a PT-scheme, authentic or artificially inoculated food samples are necessary to accurately evaluate the analytical performances. Reference materials, used as PT items because of their convenience, may present commutability issues leading to inaccurate penalizing conclusions for methods that would have provided accurate results on food samples. For the first time, the commutability of food microbiology PT samples was investigated. The nature of the samples provided by the organizer turned out to be an important factor because matrix effects can impact on the analytical results. © 2013 The Society for Applied Microbiology.

  16. Clinical Laboratory Practice Recommendations for the Use of Cardiac Troponin in Acute Coronary Syndrome: Expert Opinion from the Academy of the American Association for Clinical Chemistry and the Task Force on Clinical Applications of Cardiac Bio-Markers of the International Federation of Clinical Chemistry and Laboratory Medicine.

    PubMed

    Wu, Alan H B; Christenson, Robert H; Greene, Dina N; Jaffe, Allan S; Kavsak, Peter A; Ordonez-Llanos, Jordi; Apple, Fred S

    2018-04-01

    This document is an essential companion to the third iteration of the National Academy of Clinical Biochemistry [NACB, 8 now the American Association for Clinical Chemistry (AACC) Academy] Laboratory Medicine Practice Guidelines (LMPG) on cardiac markers. The expert consensus recommendations were drafted in collaboration with the International Federation of Clinical Chemistry and Laboratory Medicine Task Force on Clinical Applications of Bio-Markers (IFCC TF-CB). We determined that there is sufficient clinical guidance on the use of cardiac troponin (cTn) testing from clinical practice groups. Thus, in this expert consensus document, we focused on clinical laboratory practice recommendations for high-sensitivity (hs)-cTn assays. This document utilized the expert opinion class of evidence to focus on the following 10 topics: ( a ) quality control (QC) utilization, ( b ) validation of the lower reportable analytical limits, ( c ) units to be used in reporting measurable concentrations for patients and QC materials, ( d ) 99th percentile sex-specific upper reference limits to define the reference interval; ( e ) criteria required to define hs-cTn assays, ( f ) communication with clinicians and the laboratory's role in educating clinicians regarding the influence of preanalytic and analytic problems that can confound assay results, ( g ) studies on hs-cTn assays and how authors need to document preanalytical and analytical variables, ( h ) harmonizing and standardizing assay results and the role of commutable materials, ( i ) time to reporting of results from sample receipt and sample collection, and ( j ) changes in hs-cTn concentrations over time and the role of both analytical and biological variabilities in interpreting results of serial blood collections. © 2017 American Association for Clinical Chemistry.

  17. The use of reference materials in quality assurance programmes in food microbiology laboratories.

    PubMed

    In't Veld, P H

    1998-11-24

    Nine different reference materials (RMs) for use in food and water microbiology have been developed with the support of the European Commission (EC). The production process of RMs is based on spray drying bacteria suspended in milk. The highly contaminated milk powder (HCMP) obtained is mixed with sterile milk powder to achieve the desired level of contamination and is subsequently filled into gelatine capsules. The HCMP may need to be stabilised by storage for more than a year before a stable RM can be prepared. The HCMP are mixed with sterile milk powder using a pestle and mortar in order to produce homogeneous RMs. For routine use of RMs Shewhart control charts can be produced. Based on log10 transformed counts, control limits are calculated. Rules for the interpretation of results facilitate the detection of out of control situations. Besides RMs there are also CRMs (Certified Reference Materials) that are certified by the EC Community Bureau of Reference (BCR) and are intended for occasional use. Based on the BCR certificate, user tables are produced presenting the 95% confidence limits for the number of capsules likely to be examined in practice. Also power analysis is made to indicate the minimum difference between the certified value and the observed geometric mean value in relation to the number of capsules examined.

  18. Strength and Fatigue of NT551 Silicon Nitride and NT551 Diesel Exhaust Valves

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andrews, M.J.; Wereszczak, A.A.; Kirkland, T.P.

    2000-02-01

    The content of this report is excerpted from Mark Andrew's Ph.D. Thesis (Andrews, 1999), which was funded by a DOEYOTT High Temperature Materials Laboratory Graduate Fellowship. It involves the characterization of NT551 and valves fabricated with it. Greater detail of the described issues may be found in that reference or through communications with Andrew Wereszczak.

  19. Chemical Physics of Charge Mechanisms in Nonmetallic Spacecraft Materials.

    DTIC Science & Technology

    1979-05-01

    techniques may not provide data truly representative of actual in-orbit space - craft charging effects . The results of the discharge characterization...phenomena, commonly referred to collectively as space - !. craft charging effects , can produce undesirable and sometimes serious prob- lems with the...lifetime of future space systems requires a practical understanding of spacecraft charging phenomena and their effects . The laboratory program

  20. Cleanup Verification Package for the 618-2 Burial Ground

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    W. S. Thompson

    2006-12-28

    This cleanup verification package documents completion of remedial action for the 618-2 Burial Ground, also referred to as Solid Waste Burial Ground No. 2; Burial Ground No. 2; 318-2; and Dry Waste Burial Site No. 2. This waste site was used primarily for the disposal of contaminated equipment, materials and laboratory waste from the 300 Area Facilities.

  1. Expression and purification of a functional recombinant aspartate aminotransferase (AST) from Escherichia coli.

    PubMed

    Zou, Lihui; Zhao, Haijian; Wang, Daguang; Wang, Meng; Zhang, Chuanbao; Xiao, Fei

    2014-07-01

    Aspartate aminotransferase (AST; E.C. 2.6.1.1), a vitamin B6-dependent enzyme, preferentially promotes the mutual transformation of aspartate and α-ketoglutarate to oxaloacetate and glutamate. It plays a key role in amino acid metabolism and has been widely recommended as a biomarker of liver and heart damage. Our study aimed to evaluate the extensive preparation of AST and its application in quality control in clinical laboratories. We describe a scheme to express and purify the 6His-AST fusion protein. An optimized sequence coding AST was synthesized and transformed into Escherichia coli BL21 (DE3) strain for protein expression. Ideally, the fusion protein has a volumetric productivity achieving 900 mg/l cultures. After affinity chromatography, the enzyme activity of purified AST reached 150,000 U/L. Commutability assessment between the engineered AST and standard AST from Roche suggested that the engineered AST was the better candidate for the reference material. Moreover, the AST showed high stability during long-term storage at -20ºC. In conclusion, the highly soluble 6His-tagged AST can become a convenient tool for supplying a much better and cheaper standard or reference material for the clinical laboratory.

  2. A new graphite preparation line for AMS 14C dating in the Zagreb Radiocarbon Laboratory

    NASA Astrophysics Data System (ADS)

    Krajcar Bronić, I.; Horvatinčić, N.; Sironić, A.; Obelić, B.; Barešić, J.; Felja, I.

    2010-04-01

    The new line for preparation of graphite samples for 14C dating by AMS has been constructed in the Zagreb Radiocarbon Laboratory. The performance of the rig and sample preparation procedure has been validated by preparing graphites from various reference materials of known 14C activity. The yield of the graphitization was good and the measured fraction of modern carbon ( Fm) values have not significantly deviated from the expected ones. Detailed analysis of measured Fm values indicates a slight bias to more positive values and should be carefully investigated.

  3. Health hazards associated with the use of di-(2-ethylhexyl) phthalate (commonly referred to as DOP) in HEPA filter test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-01-01

    Di-(2-ethylhexyl) phthalate (DEHP), commonly referred to as di-octyl phthalate, is an important production chemical in the US. In addition to its major use as an additive in plastics, DEHP is widely used to evaluate the effectiveness of high efficiency particulate air (HEPA) filters. Historically, DEHP was also used in quantitative fit testing for respirators. Evaluations of this compound a decade ago showed that it can induce hepatocellular carcinomas in laboratory animals. Although most Department of Energy (DOE) facilities have since discontinued using DEHP in respirator fit testing, DEHP continues to be used for evaluating HEPA filters. This report summarizes availablemore » information on the toxicity, mutagenicity, carcinogenicity, and other hazards and problems posed by DEHP, specifically with reference to HEPA filter testing. Information on work practice improvements as well as the availability and suitability of DEHP substitutes are also presented. This material should assist the DOE in the safe use of this material.« less

  4. NACA Conference on Aircraft Loads, Structures, and Flutter

    NASA Technical Reports Server (NTRS)

    1957-01-01

    This document contains reproductions of technical papers on some of the most recent research results on aircraft loads, flutter, and structures from the NACA laboratories. These papers were presented by members of the staff of the NACA laboratories at the Conference held at the Langley Aeronautical Laboratory March 5, 6, and 7, 1957. The primary purpose of this Conference was to convey to contractors of the military services and others concerned with the design of aircraft these recent research results and to provide those attending an opportunity to discuss the results. The papers in this document are in the same form in which they were presented at the Conference in order to facilitate their prompt distribution. The original presentation and this record are considered as complementary to, rather than as substitutes for, the Committee?s more complete and formal reports. Accordingly, if information from this document is utilized it is requested that this document not be listed as a reference. Individual reports dealing with most of the information presented at the Conference will subsequently be published by NACA and will therefore be suitable as reference material.

  5. Characterization of Ricin and R. communis Agglutinin Reference Materials.

    PubMed

    Worbs, Sylvia; Skiba, Martin; Söderström, Martin; Rapinoja, Marja-Leena; Zeleny, Reinhard; Russmann, Heiko; Schimmel, Heinz; Vanninen, Paula; Fredriksson, Sten-Åke; Dorner, Brigitte G

    2015-11-26

    Ricinus communis intoxications have been known for centuries and were attributed to the toxic protein ricin. Due to its toxicity, availability, ease of preparation, and the lack of medical countermeasures, ricin attracted interest as a potential biological warfare agent. While different technologies for ricin analysis have been established, hardly any universally agreed-upon "gold standards" are available. Expert laboratories currently use differently purified in-house materials, making any comparison of accuracy and sensitivity of different methods nearly impossible. Technically challenging is the discrimination of ricin from R. communis agglutinin (RCA120), a less toxic but highly homologous protein also contained in R. communis. Here, we established both highly pure ricin and RCA120 reference materials which were extensively characterized by gel electrophoresis, liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI MS/MS), and matrix-assisted laser desorption ionization-time of flight approaches as well as immunological and functional techniques. Purity reached >97% for ricin and >99% for RCA120. Different isoforms of ricin and RCA120 were identified unambiguously and distinguished by LC-ESI MS/MS. In terms of function, a real-time cytotoxicity assay showed that ricin is approximately 300-fold more toxic than RCA120. The highly pure ricin and RCA120 reference materials were used to conduct an international proficiency test.

  6. Development and co-validation of porcine insulin certified reference material by high-performance liquid chromatography-isotope dilution mass spectrometry.

    PubMed

    Wu, Liqing; Takatsu, Akiko; Park, Sang-Ryoul; Yang, Bin; Yang, Huaxin; Kinumi, Tomoya; Wang, Jing; Bi, Jiaming; Wang, Yang

    2015-04-01

    This article concerns the development and co-validation of a porcine insulin (pINS) certified reference material (CRM) produced by the National Institute of Metrology, People's Republic of China. Each CRM unit contained about 15 mg of purified solid pINS. The moisture content, amount of ignition residue, molecular mass, and purity of the pINS were measured. Both high-performance liquid chromatography-isotope dilution mass spectrometry and a purity deduction method were used to determine the mass fraction of the pINS. Fifteen units were selected to study the between-bottle homogeneity, and no inhomogeneity was observed. A stability study concluded that the CRM was stable for at least 12 months at -20 °C. The certified value of the CRM was (0.892 ± 0.036) g/g. A co-validation of the CRM was performed among Chinese, Japanese, and Korean laboratories under the framework of the Asian Collaboration on Reference Materials. The co-validation results agreed well with the certified value of the CRM. Consequently, the pINS CRM may be used as a calibration material or as a validation standard for pharmaceutical purposes to improve the quality of pharmaceutical products.

  7. Characterization of Ricin and R. communis Agglutinin Reference Materials

    PubMed Central

    Worbs, Sylvia; Skiba, Martin; Söderström, Martin; Rapinoja, Marja-Leena; Zeleny, Reinhard; Russmann, Heiko; Schimmel, Heinz; Vanninen, Paula; Fredriksson, Sten-Åke; Dorner, Brigitte G.

    2015-01-01

    Ricinus communis intoxications have been known for centuries and were attributed to the toxic protein ricin. Due to its toxicity, availability, ease of preparation, and the lack of medical countermeasures, ricin attracted interest as a potential biological warfare agent. While different technologies for ricin analysis have been established, hardly any universally agreed-upon “gold standards” are available. Expert laboratories currently use differently purified in-house materials, making any comparison of accuracy and sensitivity of different methods nearly impossible. Technically challenging is the discrimination of ricin from R. communis agglutinin (RCA120), a less toxic but highly homologous protein also contained in R. communis. Here, we established both highly pure ricin and RCA120 reference materials which were extensively characterized by gel electrophoresis, liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI MS/MS), and matrix-assisted laser desorption ionization–time of flight approaches as well as immunological and functional techniques. Purity reached >97% for ricin and >99% for RCA120. Different isoforms of ricin and RCA120 were identified unambiguously and distinguished by LC-ESI MS/MS. In terms of function, a real-time cytotoxicity assay showed that ricin is approximately 300-fold more toxic than RCA120. The highly pure ricin and RCA120 reference materials were used to conduct an international proficiency test. PMID:26703723

  8. Correcting intensity loss errors in the absence of texture-free reference samples during pole figure measurement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saleh, Ahmed A., E-mail: asaleh@uow.edu.au

    Even with the use of X-ray polycapillary lenses, sample tilting during pole figure measurement results in a decrease in the recorded X-ray intensity. The magnitude of this error is affected by the sample size and/or the finite detector size. These errors can be typically corrected by measuring the intensity loss as a function of the tilt angle using a texture-free reference sample (ideally made of the same alloy as the investigated material). Since texture-free reference samples are not readily available for all alloys, the present study employs an empirical procedure to estimate the correction curve for a particular experimental configuration.more » It involves the use of real texture-free reference samples that pre-exist in any X-ray diffraction laboratory to first establish the empirical correlations between X-ray intensity, sample tilt and their Bragg angles and thereafter generate correction curves for any Bragg angle. It will be shown that the empirically corrected textures are in very good agreement with the experimentally corrected ones. - Highlights: •Sample tilting during X-ray pole figure measurement leads to intensity loss errors. •Texture-free reference samples are typically used to correct the pole figures. •An empirical correction procedure is proposed in the absence of reference samples. •The procedure relies on reference samples that pre-exist in any texture laboratory. •Experimentally and empirically corrected textures are in very good agreement.« less

  9. Assuring the Quality of Next-Generation Sequencing in Clinical Microbiology and Public Health Laboratories.

    PubMed

    Gargis, Amy S; Kalman, Lisa; Lubin, Ira M

    2016-12-01

    Clinical microbiology and public health laboratories are beginning to utilize next-generation sequencing (NGS) for a range of applications. This technology has the potential to transform the field by providing approaches that will complement, or even replace, many conventional laboratory tests. While the benefits of NGS are significant, the complexities of these assays require an evolving set of standards to ensure testing quality. Regulatory and accreditation requirements, professional guidelines, and best practices that help ensure the quality of NGS-based tests are emerging. This review highlights currently available standards and guidelines for the implementation of NGS in the clinical and public health laboratory setting, and it includes considerations for NGS test validation, quality control procedures, proficiency testing, and reference materials. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  10. Compositional variability of the Martian surface

    NASA Technical Reports Server (NTRS)

    Adams, John B.; Smith, Milton O.

    1991-01-01

    Spectral reflectance data from Viking Landers and Orbiters and from telescopic observations were analyzed with the objective of isolating compositional information about the Martian surface and assessing compositional variability. Two approaches were used to calibrate the data to reflectance to permit direct comparisons with laboratory reference spectra of well characterized materials. In Viking Lander multispectral images (six spectral bands) most of the spectral variation is caused by changes in lighting geometry within individual scenes, from scene to scene, and over time. Lighting variations are both wavelength independent and wavelength dependent. By calibrating lander image radiance values to reflectance using spectral mixture analysis, the possible range of compositions was assessed with reference to a collection of laboratory samples, also resampled to the lander spectral bands. All spectra from the lander images studied plot (in six-space) within a planar triangle having at the apexes the respective spectra of tan basaltic palagonite, gray basalt, and shale. Within this plane all lander spectra fit as mixtures of these three endmembers. Reference spectra that plot outside of the triangle are unable to account for the spectral variation observed in the images.

  11. Chapter 23: International Standard reagents for harmonization of HPV serology and DNA assays--an update.

    PubMed

    Pagliusi, Sonia R; Dillner, Joakim; Pawlita, Michael; Quint, Wim G V; Wheeler, Cosette M; Ferguson, M

    2006-08-31

    International reference materials such as International Standard reagents facilitate quality assurance of essential biopharmaceutical products and related in vitro diagnostic tests. Standardization of antibody and DNA measurements and harmonization of laboratory procedures are key to the success of cancer prevention strategies through screening methods as well as for development and implementation of vaccination against the human papillomavirus (HPV). The WHO supported the preparation and initial analysis of a panel of candidate serological and DNA reference reagents aimed at facilitating inter-laboratory comparisons and detection of HPV worldwide. Two international collaborative studies assessed the performance of various HPV antibody and HPV-DNA detection assays and examined the feasibility of generating HPV antibody and DNA standard reagents. These studies showed that improvement in performance and comparability of assays is urgently needed and that the use of the same International Standard reference reagent could significantly improve performance and comparability. It is hoped that the establishment of International Units and International Standards for HPV antibody and DNA analysis will be pursued with high priority.

  12. Soil simulant sourcing for the ExoMars rover testbed

    NASA Astrophysics Data System (ADS)

    Gouache, Thibault P.; Patel, Nildeep; Brunskill, Christopher; Scott, Gregory P.; Saaj, Chakravarthini M.; Matthews, Marcus; Cui, Liang

    2011-06-01

    ExoMars is the European Space Agency (ESA) mission to Mars planned for launch in 2018, focusing on exobiology with the primary objective of searching for any traces of extant or extinct carbon-based micro-organisms. The on-surface mission is performed by a near-autonomous mobile robotic vehicle (also referred to as the rover) with a mission design life of 180 sols (Patel et al., 2010). In order to obtain useful data on the tractive performance of the ExoMars rover before flight, it is necessary to perform mobility tests on representative soil simulant materials producing a Martian terrain analogue under terrestrial laboratory conditions. Three individual types of regolith shown to be found extensively on the Martian surface were identified for replication using commercially available terrestrial materials, sourced from UK sites in order to ensure easy supply and reduce lead times for delivery. These materials (also referred to as the Engineering Soil (ES-x) simulants) are: a fine dust analogue (ES-1); a fine aeolian sand analogue (ES-2); and a coarse sand analogue (ES-3). Following a detailed analysis, three fine sand regolith types were identified from commercially available products. Each material was used in its off-the-shelf state, except for ES-2, where further processing methods were used to reduce the particle size range. These materials were tested to determine their physical characteristics, including the particle size distribution, particle density, particle shape (including angularity/sphericity) and moisture content. The results are analysed to allow comparative analysis with existing soil simulants and the published results regarding in situ analysis of Martian soil on previous NASA (National Aeronautics and Space Administration) missions. The findings have shown that in some cases material properties vary significantly from the specifications provided by material suppliers. This has confirmed the need for laboratory testing to determine the actual parameters to prove that standard geotechnical processes are indeed suitable. The outcomes have allowed the confirmation of each simulant material as suitable for replicating their respective regolith types.

  13. Development and evaluation of a suite of isotope reference gases for methane in air

    NASA Astrophysics Data System (ADS)

    Sperlich, Peter; Uitslag, Nelly A. M.; Richter, Jürgen M.; Rothe, Michael; Geilmann, Heike; van der Veen, Carina; Röckmann, Thomas; Blunier, Thomas; Brand, Willi A.

    2016-08-01

    Measurements from multiple laboratories have to be related to unifying and traceable reference material in order to be comparable. However, such fundamental reference materials are not available for isotope ratios in atmospheric methane, which led to misinterpretations of combined data sets in the past. We developed a method to produce a suite of synthetic CH4-in-air standard gases that can be used to unify methane isotope ratio measurements of laboratories in the atmospheric monitoring community. Therefore, we calibrated a suite of pure methane gases of different methanogenic origin against international referencing materials that define the VSMOW (Vienna Standard Mean Ocean Water) and VPDB (Vienna Pee Dee Belemnite) isotope scales. The isotope ratios of our pure methane gases range between -320 and +40 ‰ for δ2H-CH4 and between -70 and -40 ‰ for δ13C-CH4, enveloping the isotope ratios of tropospheric methane (about -85 and -47 ‰ for δ2H-CH4 and δ13C-CH4 respectively). Estimated uncertainties, including the full traceability chain, are < 1.5 ‰ and < 0.2 ‰ for δ2H and δ13C calibrations respectively. Aliquots of the calibrated pure methane gases have been diluted with methane-free air to atmospheric methane levels and filled into 5 L glass flasks. The synthetic CH4-in-air standards comprise atmospheric oxygen/nitrogen ratios as well as argon, krypton and nitrous oxide mole fractions to prevent gas-specific measurement artefacts. The resulting synthetic CH4-in-air standards are referred to as JRAS-M16 (Jena Reference Air Set - Methane 2016) and will be available to the atmospheric monitoring community. JRAS-M16 may be used as unifying isotope scale anchor for isotope ratio measurements in atmospheric methane, so that data sets can be merged into a consistent global data frame.

  14. The use of portable equipment for the activity concentration index determination of building materials: method validation and survey of building materials on the Belgian market.

    PubMed

    Stals, M; Verhoeven, S; Bruggeman, M; Pellens, V; Schroeyers, W; Schreurs, S

    2014-01-01

    The Euratom BSS requires that in the near future (2015) the building materials for application in dwellings or buildings such as offices or workshops are screened for NORM nuclides. The screening tool is the activity concentration index (ACI). Therefore it is expected that a large number of building materials will be screened for NORM and thus require ACI determination. Nowadays, the proposed standard for determination of building material ACI is a laboratory analyses technique with high purity germanium spectrometry and 21 days equilibrium delay. In this paper, the B-NORM method for determination of building material ACI is assessed as a faster method that can be performed on-site, alternative to the aforementioned standard method. The B-NORM method utilizes a LaBr3(Ce) scintillation probe to obtain the spectral data. Commercially available software was applied to comprehensively take into account the factors determining the counting efficiency. The ACI was determined by interpreting the gamma spectrum from (226)Ra and its progeny; (232)Th progeny and (40)K. In order to assess the accuracy of the B-NORM method, a large selection of samples was analyzed by a certified laboratory and the results were compared with the B-NORM results. The results obtained with the B-NORM method were in good correlation with the results obtained by the certified laboratory, indicating that the B-NORM method is an appropriate screening method to assess building material ACI. The B-NORM method was applied to analyze more than 120 building materials on the Belgian market. No building materials that exceed the proposed reference level of 1 mSv/year were encountered. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. A fundamental parameters approach to calibration of the Mars Exploration Rover Alpha Particle X-ray Spectrometer

    NASA Astrophysics Data System (ADS)

    Campbell, J. L.; Lee, M.; Jones, B. N.; Andrushenko, S. M.; Holmes, N. G.; Maxwell, J. A.; Taylor, S. M.

    2009-04-01

    The detection sensitivities of the Alpha Particle X-ray Spectrometer (APXS) instruments on the Mars Exploration Rovers for a wide range of elements were experimentally determined in 2002 using spectra of geochemical reference materials. A flight spare instrument was similarly calibrated, and the calibration exercise was then continued for this unit with an extended set of geochemical reference materials together with pure elements and simple chemical compounds. The flight spare instrument data are examined in detail here using a newly developed fundamental parameters approach which takes precise account of all the physics inherent in the two X-ray generation techniques involved, namely, X-ray fluorescence and particle-induced X-ray emission. The objectives are to characterize the instrument as fully as possible, to test this new approach, and to determine the accuracy of calibration for major, minor, and trace elements. For some of the lightest elements the resulting calibration exhibits a dependence upon the mineral assemblage of the geological reference material; explanations are suggested for these observations. The results will assist in designing the overall calibration approach for the APXS on the Mars Science Laboratory mission.

  16. Interlaboratory study of a method for determining nonvolatile organic carbon in aquifer materials

    USGS Publications Warehouse

    Caughey, M.E.; Barcelona, M.J.; Powell, R.M.; Cahill, R.A.; Gron, C.; Lawrenz, D.; Meschi, P.L.

    1995-01-01

    The organic carbon fraction in aquifer materials exerts a major influence on the subsurface mobilities of organic and organic-associated contaminants. The spatial distribution of total organic carbon (TOC) in aquifer materials must be determined before the transport of hydrophobic organic pollutants in aquifers can be modeled accurately. Previous interlaboratory studies showed that it is difficult to measure TOC concentrations 1%. We have tested a new analytical method designed to improve the accuracy and precision of nonvolatile TOC quantitation in geologic materials that also contain carbonate minerals. Four authentic aquifer materials and one NIST standard reference material were selected as test materials for a blind collaborative study. Nonvolatile TOC in these materials ranged from 0.05 to 1.4%, while TIC ranged from 0.46 to 12.6%. Sample replicates were digested with sulfurous acid, dried at 40??C, and then combusted at 950??C using LECO or UIC instruments. For the three test materials that contained >2% TIC, incomplete acidification resulted in a systematic positive bias of TOC values reported by five of the six laboratories that used the test method. Participants did not have enough time to become proficient with the new method before they analyzed the test materials. A seventh laboratory successfully used an alternative method that analyzed separate liquid and solid fractions of the acidified sample residues. ?? 1995 Springer-Verlag.

  17. Preparation of waterproof OSL dosimeters from hygroscopic materials with a special reference to NaCl:Cu

    NASA Astrophysics Data System (ADS)

    More, Y. K.; Wankhede, S. P.; Patil, R. R.; Kulkarni, M. S.; Kumar, Munish; Moharil, S. V.

    2016-05-01

    Optically stimulated luminescence (OSL) originally developed for geological/archaeological dating, has been found very useful for diverse applications in the field of radiation dosimetry. There is still a scarcity of OSL materials with demonstrated properties suited to dosimetry applications. Progress on the development of OSL materials with engineered properties has been slow and most research has focused on the OSL characterization of existing materials. One of the reasons for availability of only a handful of OSL dosimetry materials with adequate properties is that they have to satisfy certain stringent conditions necessary for such applications. Especially, hygroscopic materials are considered totally unsuitable. The efforts were made in our laboratory to overcome this problem. It is shown here that "water-proof" dosimeters can be prepared from even hygroscopic materials such as NaCl.

  18. δ15N measurement of organic and inorganic substances by EA-IRMS: a speciation-dependent procedure.

    PubMed

    Gentile, Natacha; Rossi, Michel J; Delémont, Olivier; Siegwolf, Rolf T W

    2013-01-01

    Little attention has been paid so far to the influence of the chemical nature of the substance when measuring δ(15)N by elemental analysis (EA)-isotope ratio mass spectrometry (IRMS). Although the bulk nitrogen isotope analysis of organic material is not to be questioned, literature from different disciplines using IRMS provides hints that the quantitative conversion of nitrate into nitrogen presents difficulties. We observed abnormal series of δ(15)N values of laboratory standards and nitrates. These unexpected results were shown to be related to the tailing of the nitrogen peak of nitrate-containing compounds. A series of experiments were set up to investigate the cause of this phenomenon, using ammonium nitrate (NH(4)NO(3)) and potassium nitrate (KNO(3)) samples, two organic laboratory standards as well as the international secondary reference materials IAEA-N1, IAEA-N2-two ammonium sulphates [(NH(4))(2)SO(4)]-and IAEA-NO-3, a potassium nitrate. In experiment 1, we used graphite and vanadium pentoxide (V(2)O(5)) as additives to observe if they could enhance the decomposition (combustion) of nitrates. In experiment 2, we tested another elemental analyser configuration including an additional section of reduced copper in order to see whether or not the tailing could originate from an incomplete reduction process. Finally, we modified several parameters of the method and observed their influence on the peak shape, δ(15)N value and nitrogen content in weight percent of nitrogen of the target substances. We found the best results using mere thermal decomposition in helium, under exclusion of any oxygen. We show that the analytical procedure used for organic samples should not be used for nitrates because of their different chemical nature. We present the best performance given one set of sample introduction parameters for the analysis of nitrates, as well as for the ammonium sulphate IAEA-N1 and IAEA-N2 reference materials. We discuss these results considering the thermochemistry of the substances and the analytical technique itself. The results emphasise the difference in chemical nature of inorganic and organic samples, which necessarily involves distinct thermochemistry when analysed by EA-IRMS. Therefore, they should not be processed using the same analytical procedure. This clearly impacts on the way international secondary reference materials should be used for the calibration of organic laboratory standards.

  19. A novel method for room temperature distribution and conservation of RNA and DNA reference materials for guaranteeing performance of molecular diagnostics in onco-hematology: A GBMHM study.

    PubMed

    Cayuela, Jean-Michel; Mauté, Carole; Fabre, Anne-Lise; Nibourel, Olivier; Dulucq, Stéphanie; Delabesse, Eric; Villarèse, Patrick; Hayette, Sandrine; Mozziconacci, Marie-Joelle; Macintyre, Elizabeth

    2015-10-01

    Performance of methods used for molecular diagnostics must be closely controlled by regular analysis of internal quality controls. However, conditioning, shipping and long lasting storage of nucleic acid controls remain problematic. Therefore, we evaluated the minicapsule-based innovative process developed by Imagene (Evry, France) for implementing DNA and RNA controls designed for clonality assessment of lymphoproliferations and BCR-ABL1 mRNA quantification, respectively. DNA samples were extracted from 12 cell lines selected for giving specific amplifications with most BIOMED-2 PCR tubes. RNA samples were extracted from 8 cell line mixtures expressing various BCR-ABL1 transcript levels. DNA and RNA were encapsulated by Imagene and shipped at room temperature to participating laboratories. Biologists were asked to report quality data of recovered nucleic acids as well as PCR results. Encapsulated nucleic acids samples were easily and efficiently recovered from minicapsules. The expected rearrangements at immunoglobulin, T-cell receptor and BCL2 loci were detected in DNA samples by all laboratories. Quality of RNA was consistent between laboratories and met the criteria requested for quantification of BCR-ABL1 transcripts. Expression levels measured by the 5 laboratories were within ±2 fold interval from the corresponding pre-encapsulation reference value. Moreover aging studies of encapsulated RNA simulating up to 100 years storage at room temperature show no bias in quantitative outcome. Therefore, Imagene minicapsules are suitable for storage and distribution at room temperature of genetic material designed for proficiency control of molecular diagnostic methods based on end point or real-time quantitative PCR. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  20. Documentation of operational protocol for the use of MAMA software

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schwartz, Daniel S.

    2016-01-21

    Image analysis of Scanning Electron Microscope (SEM) micrographs is a complex process that can vary significantly between analysts. The factors causing the variation are numerous, and the purpose of Task 2b is to develop and test a set of protocols designed to minimize variation in image analysis between different analysts and laboratories, specifically using the MAMA software package, Version 2.1. The protocols were designed to be “minimally invasive”, so that expert SEM operators will not be overly constrained in the way they analyze particle samples. The protocols will be tested using a round-robin approach where results from expert SEM usersmore » at Los Alamos National Laboratory, Lawrence Livermore National Laboratory, Pacific Northwest National Laboratory, Savannah River National Laboratory, and the National Institute of Standards and Testing will be compared. The variation of the results will be used to quantify uncertainty in the particle image analysis process. The round-robin exercise will proceed with 3 levels of rigor, each with their own set of protocols, as described below in Tasks 2b.1, 2b.2, and 2b.3. The uncertainty will be developed using NIST standard reference material SRM 1984 “Thermal Spray Powder – Particle Size Distribution, Tungsten Carbide/Cobalt (Acicular)” [Reference 1]. Full details are available in the Certificate of Analysis, posted on the NIST website (http://www.nist.gov/srm/).« less

  1. Collaborative study for the establishment of the WHO 3(rd) International Standard for Endotoxin, the Ph. Eur. endotoxin biological reference preparation batch 5 and the USP Reference Standard for Endotoxin Lot H0K354.

    PubMed

    Findlay, L; Desai, T; Heath, A; Poole, S; Crivellone, M; Hauck, W; Ambrose, M; Morris, T; Daas, A; Rautmann, G; Buchheit, K H; Spieser, J M; Terao, E

    2015-01-01

    An international collaborative study was organised jointly by the World Health Organization (WHO)/National Institute for Biological Standards and Control (NIBSC), the United States Pharmacopeia (USP) and the European Directorate for the Quality of Medicines & HealthCare (EDQM/Council of Europe) for the establishment of harmonised replacement endotoxin standards for these 3 organisations. Thirty-five laboratories worldwide, including Official Medicines Control Laboratories (OMCLs) and manufacturers enrolled in the study. Three candidate preparations (10/178, 10/190 and 10/196) were produced with the same material and same formulation as the current reference standards with the objective of generating a new (3(rd)) International Standard (IS) with the same potency (10 000 IU/vial) as the current (2(nd)) IS, as well as new European Pharmacopoeia (Ph. Eur.). and USP standards. The suitability of the candidate preparations to act as the reference standard in assays for endotoxin performed according to compendial methods was evaluated. Their potency was calibrated against the WHO 2(nd) IS for Endotoxin (94/580). Gelation and photometric methods produced similar results for each of the candidate preparations. The overall potency estimates for the 3 batches were comparable. Given the intrinsic assay precision, the observed differences between the batches may be considered unimportant for the intended use of these materials. Overall, these results were in line with those generated for the establishment of the current preparations of reference standards. Accelerated degradation testing of vials stored at elevated temperatures supported the long-term stability of the 3 candidate preparations. It was agreed between the 3 organisations that batch 10/178 be shared between WHO and EDQM and that batches 10/190 and 10/196 be allocated to USP, with a common assigned value of 10 000 IU/vial. This value maintains the continuity of the global harmonisation of reference materials and unitage for the testing of endotoxins in parenteral pharmaceutical products. Based on the results of the collaborative study, batch 10/178 was established by the European Pharmacopoeia Commission as the Ph. Eur. Endotoxin Biological Reference Preparation (BRP) batch 5. The same batch was also established by the Expert Committee on Biological Standardisation (ECBS) of WHO as the WHO 3(rd) IS for Endotoxin. Batch 10/190 was adopted as the USP Endotoxin Reference Standard, lot H0K354 and vials from this same batch (10/190) will serve as the United States Food and Drug Administration (USFDA) Endotoxin Standard, EC-7.

  2. Interlaboratory trial for measurement of vitamin D and 25(OH)D in foods and a dietary supplement using liquid chromatography-mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    Assessment of total vitamin D intake from foods and dietary supplements (DSs) may be incomplete if 25-hydroxyvitamin D [25(OH)D] intake is not included. However, 25(OH)D data for such intake assessments are lacking, no food or DS reference materials (RMs) are available, and comparison of laboratory...

  3. Perry Johnson Laboratory Accreditation, Inc. (PJLA)

    DTIC Science & Technology

    2011-03-28

    Accreditation Body, established in 1999, located in Troy, Michigan • Current Accreditation Programs– ISO / IEC 17025 :2005 and DoD ELAP, EPA NLLAP...Upcoming Accreditation Programs–Field Site Sampling & Measurement Organizations (FSMO)–TNI Volume 1 and 2, Reference Material Producers– ISO Guide...Testing/Calibration – 17025 -Testing–120 – 17025 -Calibration–191 – 17025 & DoD ELAP–14 (5 Pending) – 17025 and EPA NLLAP–1 – Pending

  4. Shock Waves and Defects in Energetic Materials, a Match Made in MD Heaven

    NASA Astrophysics Data System (ADS)

    Wood, Mitchell; Kittell, David; Yarrington, Cole; Thompson, Aidan

    2017-06-01

    Shock wave interactions with defects, such as pores, are known to play a key role in the chemical initiation of energetic materials. In this talk the shock response of Hexanitrostilbene (HNS) is studied through large scale reactive molecular dynamics (RMD) simulations. These RMD simulations provide a unique opportunity to elucidate mechanisms of viscoplastic pore collapse which are often neglected in larger scale hydrodynamic models. A discussion of the macroscopic effects of this viscoplastic material response, such as its role in hot spot formation and eventual initiation, will be provided. Through this work we have been able to map a transition from purely viscoplastic to fluid-like pore collapse that is a function of shock strength, pore size and material strength. In addition, these findings are important reference data for the validation of future multi-scale modeling efforts of the shock response of heterogeneous materials. Examples of how these RMD results are translated into mesoscale models will also be addressed. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the US DOE NNSA under Contract No. DE- AC04-94AL85000.

  5. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; preparation procedure for aquatic biological material determined for trace metals

    USGS Publications Warehouse

    Hoffman, Gerald L.

    1996-01-01

    A method for the chemical preparation of tissue samples that are subsequently analyzed for 22 trace metals is described. The tissue-preparation procedure was tested with three National Institute of Standards and Technology biological standard reference materials and two National Water Quality Laboratory homogenized biological materials. A low-temperature (85 degrees Celsius) nitric acid digestion followed by the careful addition of hydrogen peroxide (30-percent solution) is used to decompose the biological material. The solutions are evaporated to incipient dryness, reconstituted with 5 percent nitric acid, and filtered. After filtration the solutions were diluted to a known volume and analyzed by inductively coupled plasma-mass spectrometry (ICP-MS), inductively coupled plasma-atomic emission spectrometry (ICP-AES), and cold vapor-atomic absorption spectrophotometry (CV-AAS). Many of the metals were determined by both ICP-MS and ICP-AES. This report does not provide a detailed description of the instrumental procedures and conditions used with the three types of instrumentation for the quantitation of trace metals determined in this study. Statistical data regarding recovery, accuracy, and precision for individual trace metals determined in the biological material tested are summarized.

  6. Performance evaluation of elemental analysis/isotope ratio mass spectrometry methods for the determination of the D/H ratio in tetramethylurea and other compounds--results of a laboratory inter-comparison.

    PubMed

    Bréas, Olivier; Thomas, Freddy; Zeleny, Reinhard; Calderone, Giovanni; Jamin, Eric; Guillou, Claude

    2007-01-01

    Tetramethylurea (TMU) with a certified D/H ratio is the internal standard for Site-specific Natural Isotope Fractionation measured by Nuclear Magnetic Resonance (SNIF-NMR) analysis of wine ethanol for detection of possible adulterations (Commission Regulation 2676/90). A new batch of a TMU certified reference material (CRM) is currently being prepared. Whereas SNIF-NMR has been employed up to now, Elemental Analysis/Isotope Ratio Mass Spectrometry ((2)H-EA-IRMS) was envisaged as the method of choice for value assignment of the new CRM, as more precise (better repeatable) data might be obtained, resulting in lower uncertainty of the certified value. In order to evaluate the accuracy and intra- and inter-laboratory reproducibility of (2)H-EA-IRMS methods, a laboratory inter-comparison was carried out by analysing TMU and other organic compounds, as well as some waters. The results revealed that experienced laboratories are capable of generating robust and well comparable data, which highlights the emerging potential of IRMS in food authenticity testing. However, a systematic bias between IRMS and SNIF-NMR reference data was observed for TMU; this lack of data consistency rules out the (2)H-IRMS technique for the characterisation measurement of the new TMU CRM.

  7. Determination of reference ranges for elements in human scalp hair.

    PubMed

    Druyan, M E; Bass, D; Puchyr, R; Urek, K; Quig, D; Harmon, E; Marquardt, W

    1998-06-01

    Expected values, reference ranges, or reference limits are necessary to enable clinicians to apply analytical chemical data in the delivery of health care. Determination of references ranges is not straightforward in terms of either selecting a reference population or performing statistical analysis. In light of logistical, scientific, and economic obstacles, it is understandable that clinical laboratories often combine approaches in developing health associated reference values. A laboratory may choose to: 1. Validate either reference ranges of other laboratories or published data from clinical research or both, through comparison of patients test data. 2. Base the laboratory's reference values on statistical analysis of results from specimens assayed by the clinical reference laboratory itself. 3. Adopt standards or recommendations of regulatory agencies and governmental bodies. 4. Initiate population studies to validate transferred reference ranges or to determine them anew. Effects of external contamination and anecdotal information from clinicians may be considered. The clinical utility of hair analysis is well accepted for some elements. For others, it remains in the realm of clinical investigation. This article elucidates an approach for establishment of reference ranges for elements in human scalp hair. Observed levels of analytes from hair specimens from both our laboratory's total patient population and from a physician-defined healthy American population have been evaluated. Examination of levels of elements often associated with toxicity serves to exemplify the process of determining reference ranges in hair. In addition the approach serves as a model for setting reference ranges for analytes in a variety of matrices.

  8. Standardization in laboratory medicine: Adoption of common reference intervals to the Croatian population.

    PubMed

    Flegar-Meštrić, Zlata; Perkov, Sonja; Radeljak, Andrea

    2016-03-26

    Considering the fact that the results of laboratory tests provide useful information about the state of health of patients, determination of reference value is considered an intrinsic part in the development of laboratory medicine. There are still huge differences in the analytical methods used as well as in the associated reference intervals which could consequently significantly affect the proper assessment of patient health. In a constant effort to increase the quality of patients' care, there are numerous international initiatives for standardization and/or harmonization of laboratory diagnostics in order to achieve maximum comparability of laboratory test results and improve patient safety. Through the standardization and harmonization processes of analytical methods the ability to create unique reference intervals is achieved. Such reference intervals could be applied globally in all laboratories using methods traceable to the same reference measuring system and analysing the biological samples from the populations with similar socio-demographic and ethnic characteristics. In this review we outlined the results of the harmonization processes in Croatia in the field of population based reference intervals for clinically relevant blood and serum constituents which are in accordance with ongoing activity for worldwide standardization and harmonization based on traceability in laboratory medicine.

  9. Public health microbiology in Germany: 20 years of national reference centers and consultant laboratories.

    PubMed

    Beermann, Sandra; Allerberger, Franz; Wirtz, Angela; Burger, Reinhard; Hamouda, Osamah

    2015-10-01

    In 1995, in agreement with the German Federal Ministry of Health, the Robert Koch Institute established a public health microbiology system consisting of national reference centers (NRCs) and consultant laboratories (CLs). The goal was to improve the efficiency of infection protection by advising the authorities on possible measures and to supplement infectious disease surveillance by monitoring selected pathogens that have high public health relevance. Currently, there are 19 NRCs and 40 CLs, each appointed for three years. In 2009, an additional system of national networks of NRCs and CLs was set up in order to enhance effectiveness and cooperation within the national reference laboratory system. The aim of these networks was to advance exchange in diagnostic methods and prevention concepts among reference laboratories and to develop geographic coverage of services. In the last two decades, the German public health laboratory reference system coped with all major infectious disease challenges. The European Union and the European Centre for Disease Prevention and Control (ECDC) are considering implementing a European public health microbiology reference laboratory system. The German reference laboratory system should be well prepared to participate actively in this upcoming endeavor. Copyright © 2015 Elsevier GmbH. All rights reserved.

  10. Standardization in laboratory medicine: Adoption of common reference intervals to the Croatian population

    PubMed Central

    Flegar-Meštrić, Zlata; Perkov, Sonja; Radeljak, Andrea

    2016-01-01

    Considering the fact that the results of laboratory tests provide useful information about the state of health of patients, determination of reference value is considered an intrinsic part in the development of laboratory medicine. There are still huge differences in the analytical methods used as well as in the associated reference intervals which could consequently significantly affect the proper assessment of patient health. In a constant effort to increase the quality of patients’ care, there are numerous international initiatives for standardization and/or harmonization of laboratory diagnostics in order to achieve maximum comparability of laboratory test results and improve patient safety. Through the standardization and harmonization processes of analytical methods the ability to create unique reference intervals is achieved. Such reference intervals could be applied globally in all laboratories using methods traceable to the same reference measuring system and analysing the biological samples from the populations with similar socio-demographic and ethnic characteristics. In this review we outlined the results of the harmonization processes in Croatia in the field of population based reference intervals for clinically relevant blood and serum constituents which are in accordance with ongoing activity for worldwide standardization and harmonization based on traceability in laboratory medicine. PMID:27019800

  11. NOAA national status and trends program eleventh round intercomparison exercise results for trace metals in marine sediments and biological tissues. National status and trends program for marine environmental quality: Technical memo

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willie, S.

    1997-12-01

    A total of thirty-nine participants were included in the exercise, including OAA, USEPA, state, Australian, Canadian, Mexican and Argentinean laboratories. Two samples were sent by NRC to each participant, and contaminated marine sediment from Esquimalt harbor in British Columbia and a freeze-dried oyster tissue. Laboratories were also asked to analyze two certified reference materials (CRMs) MESS-2 and CRM 2976. The elements to be determined were Al, Cr, Fe, Ni, Cu, Zn, As, Se, Ag, Cd, Sn, Hg and Pb for both matrices, plus Be, Si, Mn, Sb and Tl for the sediments. An accepted mean and confidence interval was calculatedmore » for each analyte in the two unknown samples, laboratory biases were identified and an overall rating of superior, good, fair or others were assigned to each laboratory.« less

  12. Maintenance of reference standards in the field of viscosity

    NASA Astrophysics Data System (ADS)

    Moşulică, E. A.; Cîrneanu, I.; Constantin, N.; Rucai, V.

    2018-01-01

    Participation in the work of comparison in the field of viscosity, within the program conducted under the jurisdiction of ASTM (American Society for Testing and Materials), D-2 Committee, Subcommittee "Flow Properties," Newtonian Fluids) was necessary to ensure traceability of measuring unit of kinematic viscosity. Results of the comparison of the specialized participating laboratories on 4 continents, has proved annual capability of INM in the transmission unit of kinematic viscosity. Cannon Position Company in the US organizes co-operation program in the field of kinematic viscosity ASTM D 02.07. The company distributes standard substances Cannon viscosity participating laboratories and consolidate the results of the measurements. Physical-chemical laboratory has fully accepted the proposed schedule of the company Cannon. Final report of the comparison showed that in the year 2015 a number of 25 laboratories and institutes of metrology attented to the program.

  13. Universal immunogenicity validation and assessment during early biotherapeutic development to support a green laboratory.

    PubMed

    Bautista, Ami C; Zhou, Lei; Jawa, Vibha

    2013-10-01

    Immunogenicity support during nonclinical biotherapeutic development can be resource intensive if supported by conventional methodologies. A universal indirect species-specific immunoassay can eliminate the need for biotherapeutic-specific anti-drug antibody immunoassays without compromising quality. By implementing the R's of sustainability (reduce, reuse, rethink), conservation of resources and greener laboratory practices were achieved in this study. Statistical analysis across four biotherapeutics supported identification of consistent product performance standards (cut points, sensitivity and reference limits) and a streamlined universal anti-drug antibody immunoassay method implementation strategy. We propose an efficient, fit-for-purpose, scientifically and statistically supported nonclinical immunogenicity assessment strategy. Utilization of a universal method and streamlined validation, while retaining comparability to conventional immunoassays and meeting the industry recommended standards, provides environmental credits in the scientific laboratory. Collectively, individual reductions in critical material consumption, energy usage, waste and non-environment friendly consumables, such as plastic and paper, support a greener laboratory environment.

  14. Benefits of a Pharmacology Antimalarial Reference Standard and Proficiency Testing Program Provided by the Worldwide Antimalarial Resistance Network (WWARN)

    PubMed Central

    Lourens, Chris; Lindegardh, Niklas; Barnes, Karen I.; Guerin, Philippe J.; Sibley, Carol H.; White, Nicholas J.

    2014-01-01

    Comprehensive assessment of antimalarial drug resistance should include measurements of antimalarial blood or plasma concentrations in clinical trials and in individual assessments of treatment failure so that true resistance can be differentiated from inadequate drug exposure. Pharmacometric modeling is necessary to assess pharmacokinetic-pharmacodynamic relationships in different populations to optimize dosing. To accomplish both effectively and to allow comparison of data from different laboratories, it is essential that drug concentration measurement is accurate. Proficiency testing (PT) of laboratory procedures is necessary for verification of assay results. Within the Worldwide Antimalarial Resistance Network (WWARN), the goal of the quality assurance/quality control (QA/QC) program is to facilitate and sustain high-quality antimalarial assays. The QA/QC program consists of an international PT program for pharmacology laboratories and a reference material (RM) program for the provision of antimalarial drug standards, metabolites, and internal standards for laboratory use. The RM program currently distributes accurately weighed quantities of antimalarial drug standards, metabolites, and internal standards to 44 pharmacology, in vitro, and drug quality testing laboratories. The pharmacology PT program has sent samples to eight laboratories in four rounds of testing. WWARN technical experts have provided advice for correcting identified problems to improve performance of subsequent analysis and ultimately improved the quality of data. Many participants have demonstrated substantial improvements over subsequent rounds of PT. The WWARN QA/QC program has improved the quality and value of antimalarial drug measurement in laboratories globally. It is a model that has potential to be applied to strengthening laboratories more widely and improving the therapeutics of other infectious diseases. PMID:24777099

  15. Quality Management and Calibration

    NASA Astrophysics Data System (ADS)

    Merkus, Henk G.

    Good specification of a product’s performance requires adequate characterization of relevant properties. Particulate products are usually characterized by some PSD, shape or porosity parameter(s). For proper characterization, adequate sampling, dispersion, and measurement procedures should be available or developed and skilful personnel should use appropriate, well-calibrated/qualified equipment. The characterization should be executed, in agreement with customers, in a wellorganized laboratory. All related aspects should be laid down in a quality handbook. The laboratory should provide proof for its capability to perform the characterization of stated products and/or reference materials within stated confidence limits. This can be done either by internal validation and audits or by external GLP accreditation.

  16. Standard Reference Material (SRM 1990) for Single Crystal Diffractometer Alignment

    USGS Publications Warehouse

    Wong-Ng, W.; Siegrist, T.; DeTitta, G.T.; Finger, L.W.; Evans, H.T.; Gabe, E.J.; Enright, G.D.; Armstrong, J.T.; Levenson, M.; Cook, L.P.; Hubbard, C.R.

    2001-01-01

    An international project was successfully completed which involved two major undertakings: (1) a round-robin to demonstrate the viability of the selected standard and (2) the certification of the lattice parameters of the SRM 1990, a Standard Reference Material?? for single crystal diffractometer alignment. This SRM is a set of ???3500 units of Cr-doped Al2O3, or ruby spheres [(0 420.011 mole fraction % Cr (expanded uncertainty)]. The round-robin consisted of determination of lattice parameters of a pair of crystals' the ruby sphere as a standard, and a zeolite reference to serve as an unknown. Fifty pairs of crystals were dispatched from Hauptman-Woodward Medical Research Institute to volunteers in x-ray laboratories world-wide. A total of 45 sets of data was received from 32 laboratories. The mean unit cell parameters of the ruby spheres was found to be a=4.7608 A?? ?? 0.0062 A??, and c=12.9979 A?? ?? 0.020 A?? (95 % intervals of the laboratory means). The source of errors of outlier data was identified. The SRM project involved the certification of lattice parameters using four well-aligned single crystal diffractometers at (Bell Laboratories) Lucent Technologies and at NRC of Canada (39 ruby spheres), the quantification of the Cr content using a combined microprobe and SEM/EDS technique, and the evaluation of the mosaicity of the ruby spheres using a double-crystal spectrometry method. A confirmation of the lattice parameters was also conducted using a Guinier-Ha??gg camera. Systematic corrections of thermal expansion and refraction corrections were applied. These rubies_ are rhombohedral, with space group R3c. The certified mean unit cell parameters are a=4.76080 ?? 0.00029 A??, and c=12 99568 A?? ?? 0.00087 A?? (expanded uncertainty). These certified lattice parameters fall well within the results of those obtained from the international round-robin study. The Guinier-Ha??gg transmission measurements on five samples of powdered rubies (a=4.7610 A?? ?? 0.0013 A??, and c=12.9954 A?? ?? 0.0034 A??) agreed well with the values obtained from the single crystal spheres.

  17. Standard Reference Material (SRM 1990) For Single Crystal Diffractometer Alignment

    PubMed Central

    Wong-Ng, W.; Siegrist, T.; DeTitta, G. T.; Finger, L. W.; Evans, H. T.; Gabe, E. J.; Enright, G. D.; Armstrong, J. T.; Levenson, M.; Cook, L. P.; Hubbard, C. R.

    2001-01-01

    An international project was successfully completed which involved two major undertakings: (1) a round-robin to demonstrate the viability of the selected standard and (2) the certification of the lattice parameters of the SRM 1990, a Standard Reference Material® for single crystal diffractometer alignment. This SRM is a set of ≈3500 units of Cr-doped Al2O3, or ruby spheres [(0.420.011 mole fraction % Cr (expanded uncertainty)]. The round-robin consisted of determination of lattice parameters of a pair of crystals: the ruby sphere as a standard, and a zeolite reference to serve as an unknown. Fifty pairs of crystals were dispatched from Hauptman-Woodward Medical Research Institute to volunteers in x-ray laboratories world-wide. A total of 45 sets of data was received from 32 laboratories. The mean unit cell parameters of the ruby spheres was found to be a=4.7608 ű0.0062 Å, and c=12.9979 ű0.020 Å (95 % intervals of the laboratory means). The source of errors of outlier data was identified. The SRM project involved the certification of lattice parameters using four well-aligned single crystal diffractometers at (Bell Laboratories) Lucent Technologies and at NRC of Canada (39 ruby spheres), the quantification of the Cr content using a combined microprobe and SEM/EDS technique, and the evaluation of the mosaicity of the ruby spheres using a double-crystal spectrometry method. A confirmation of the lattice parameters was also conducted using a Guinier-Hägg camera. Systematic corrections of thermal expansion and refraction corrections were applied. These rubies– are rhombohedral, with space group R3¯c. The certified mean unit cell parameters are a=4.76080±0.00029 Å, and c=12.99568 ű0.00087 Å (expanded uncertainty). These certified lattice parameters fall well within the results of those obtained from the international round-robin study. The Guinier-Hägg transmission measurements on five samples of powdered rubies (a=4.7610 ű0.0013 Å, and c = 12.9954 ű0.0034 Å) agreed well with the values obtained from the single crystal spheres. PMID:27500067

  18. Plasma creatinine in dogs: intra- and inter-laboratory variation in 10 European veterinary laboratories

    PubMed Central

    2011-01-01

    Background There is substantial variation in reported reference intervals for canine plasma creatinine among veterinary laboratories, thereby influencing the clinical assessment of analytical results. The aims of the study was to determine the inter- and intra-laboratory variation in plasma creatinine among 10 veterinary laboratories, and to compare results from each laboratory with the upper limit of its reference interval. Methods Samples were collected from 10 healthy dogs, 10 dogs with expected intermediate plasma creatinine concentrations, and 10 dogs with azotemia. Overlap was observed for the first two groups. The 30 samples were divided into 3 batches and shipped in random order by postal delivery for plasma creatinine determination. Statistical testing was performed in accordance with ISO standard methodology. Results Inter- and intra-laboratory variation was clinically acceptable as plasma creatinine values for most samples were usually of the same magnitude. A few extreme outliers caused three laboratories to fail statistical testing for consistency. Laboratory sample means above or below the overall sample mean, did not unequivocally reflect high or low reference intervals in that laboratory. Conclusions In spite of close analytical results, further standardization among laboratories is warranted. The discrepant reference intervals seem to largely reflect different populations used in establishing the reference intervals, rather than analytical variation due to different laboratory methods. PMID:21477356

  19. Highlight on Bottlenecks in Food Allergen Analysis: Detection and Quantification by Mass Spectrometry.

    PubMed

    Planque, Mélanie; Arnould, Thierry; Renard, Patricia; Delahaut, Philippe; Dieu, Marc; Gillard, Nathlie

    2017-07-01

    Food laboratories have developed methods for testing allergens in foods. The efficiency of qualitative and quantitative methods is of prime importance in protecting allergic populations. Unfortunately, food laboratories encounter barriers to developing efficient methods. Bottlenecks include the lack of regulatory thresholds, delays in the emergence of reference materials and guidelines, and the need to detect processed allergens. In this study, ultra-HPLC coupled to tandem MS was used to illustrate difficulties encountered in determining method performances. We measured the major influences of both processing and matrix effects on the detection of egg, milk, soy, and peanut allergens in foodstuffs. The main goals of this work were to identify difficulties that food laboratories still encounter in detecting and quantifying allergens and to sensitize researchers to them.

  20. Detection of MEF-1 laboratory reference strain of poliovirus type 2 in children with poliomyelitis in India in 2002 & 2003.

    PubMed

    Deshpande, J M; Nadkarni, S S; Siddiqui, Z A

    2003-12-01

    Significant progress has been made towards eradication of poliomyelitis in India. Surveillance for acute flaccid paralysis (AFP) has reached high standards. Among the 3 types of polioviruses, type 2 had been eliminated in India and eradicated globally as of October 1999. However, we isolated wild poliovirus type 2 from a small number of polio cases in northern India in 2000 and again during December 2002 to February 2003. Using molecular tools the origin, of the wild type 2 poliovirus was investigated. Polioviruses isolated from stool samples collected from patients with AFP were differentiated as wild virus or Sabin vaccine-like by ELISA and probe hybridization assays. Complete VP1 gene nucleotide sequences of the wild type 2 poliovirus isolates were determined by reverse transcriptase polymerase chain reaction (RT-PCR), followed by cycle sequencing. VP1 nucleotide sequences were compared with those of wild type 2 polioviruses that were indigenous in India in the past as well as prototype/laboratory strains and the GenBank database. Wild poliovirus type 2 was detected in stool samples from 6 patients with AFP in western Uttar Pradesh and 1 in Gujarat. In addition, the virus was isolated from one healthy contact child and from environmental sewage sample in Moradabad where three of these patients were reported. These isolates were identified as genetically closely related to laboratory reference strain MEF-1. Molecular characterization of the isolates confirmed that there was no evidence of extensive person-to-person transmission of the virus in the community. Laboratory reference strain (MEF-1) of poliovirus type 2 caused paralytic poliomyelitis in 10 patients in September 2000 and November 2002 to February 2003. The origin of the virus was some laboratory as yet not identified. This episode highlights the urgent need for stringent containment of wild poliovirus containing materials in the laboratories across the country in order to prevent recurrence of such incidents.

  1. PHABSIM for Windows User's Manual and Exercises

    USGS Publications Warehouse

    Waddle, Terry

    2001-01-01

    This document is a combined self-study textbook and reference manual. The material is presented in the general order of a PHABSIM study placed within the context of an IFIM application. The document may also be used as reading material for a lecture-based course. This manual provides documentation of the various PHABSIM programs so every option of each program is treated.This text is not a guidebook for organization and implementation of a PHABSIM study. Use of PHABSIM should take place in the context of an IFIM application. See Bovee et al. (1998) for guidance in designing and performing a PHABSIM study as part of a larger IFIM application.The document concludes with a set of 12 laboratory exercises. Users are strongly encouraged to work through the laboratory exercises prior to applying the software to a study. Working through the exercises will enhance familiarity with the programs and answer many questions that may arise during a PHABSIM analysis.

  2. Damping Goes the Distance in Golf

    NASA Technical Reports Server (NTRS)

    2004-01-01

    In the late 1980s, Dr. Benjamin Dolgin of NASA s Jet Propulsion Laboratory developed a concept for a high-damping graphite/viscoelastic material for the Strategic Defense Initiative (popularly referred to as "Star Wars"), as part of a space-based laser anti-missile program called "Asterix." Dolgin drummed up this concept with the intention of stabilizing weapons launch platforms in space, where there is no solid ground to firmly support these structures. Without the inclusion of high-damping material, the orbital platforms were said to vibrate for 20 minutes after force was applied - a rate deemed "unacceptable" by leaders of the Strategic Defense Initiative.

  3. Proceedings of the Workshop on Nondestructive Evaluation (NDE) of Titanium Alloys (2nd) Held on 2-4 February 1982 at the Naval Research Laboratory, Underwater Sound Reference Detachment, Orlando, Florida.

    DTIC Science & Technology

    1984-07-01

    phase. The second step, swabbing with a 1 ml HF, 2 ml HN0 3 , 97 ml water solution, removed the stain, leaving a light field of alpha phase material in...microscope (SEM), the beta phase appeared as finely dispersed light lines in a dark - field of alpha phase material. 4.2 Ultrasonic Measurements The...appropriate couplants were used in this research. Aerotech couplant • (a light oil) was used for the wave velocity measurements. A 2 mm thick elastomer

  4. Extragalactic astronomy: The universe beyond our galaxy

    NASA Technical Reports Server (NTRS)

    Jacobs, K. C.

    1976-01-01

    This single-topic brochure is for high school physical science teachers to use in introducing students to extragalactic astronomy. The material is presented in three parts: the fundamental content of extragalactic astronomy; modern discoveries delineated in greater detail; and a summary of the earlier discussions within the structure of the Big-Bang Theory of evolution. Each of the three sections is followed by student exercises (activities, laboratory projects, and questions-and-answers). The unit close with a glossary which explains unfamilar terms used in the text and a collection of teacher aids (literature references and audiovisual materials for utilization in further study).

  5. Preparation of waterproof OSL dosimeters from hygroscopic materials with a special reference to NaCl:Cu

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    More, Y. K., E-mail: moreyogesh153@gmail.com; Moharil, S. V.; Wankhede, S. P.

    Optically stimulated luminescence (OSL) originally developed for geological/archaeological dating, has been found very useful for diverse applications in the field of radiation dosimetry. There is still a scarcity of OSL materials with demonstrated properties suited to dosimetry applications. Progress on the development of OSL materials with engineered properties has been slow and most research has focused on the OSL characterization of existing materials. One of the reasons for availability of only a handful of OSL dosimetry materials with adequate properties is that they have to satisfy certain stringent conditions necessary for such applications. Especially, hygroscopic materials are considered totally unsuitable.more » The efforts were made in our laboratory to overcome this problem. It is shown here that “water-proof” dosimeters can be prepared from even hygroscopic materials such as NaCl.« less

  6. Generation and Characterization of Six Recombinant Botulinum Neurotoxins as Reference Material to Serve in an International Proficiency Test.

    PubMed

    Weisemann, Jasmin; Krez, Nadja; Fiebig, Uwe; Worbs, Sylvia; Skiba, Martin; Endermann, Tanja; Dorner, Martin B; Bergström, Tomas; Muñoz, Amalia; Zegers, Ingrid; Müller, Christian; Jenkinson, Stephen P; Avondet, Marc-Andre; Delbrassinne, Laurence; Denayer, Sarah; Zeleny, Reinhard; Schimmel, Heinz; Åstot, Crister; Dorner, Brigitte G; Rummel, Andreas

    2015-11-26

    The detection and identification of botulinum neurotoxins (BoNT) is complex due to the existence of seven serotypes, derived mosaic toxins and more than 40 subtypes. Expert laboratories currently use different technical approaches to detect, identify and quantify BoNT, but due to the lack of (certified) reference materials, analytical results can hardly be compared. In this study, the six BoNT/A1-F1 prototypes were successfully produced by recombinant techniques, facilitating handling, as well as improving purity, yield, reproducibility and biosafety. All six BoNTs were quantitatively nicked into active di-chain toxins linked by a disulfide bridge. The materials were thoroughly characterized with respect to purity, identity, protein concentration, catalytic and biological activities. For BoNT/A₁, B₁ and E₁, serotypes pathogenic to humans, the catalytic activity and the precise protein concentration were determined by Endopep-mass spectrometry and validated amino acid analysis, respectively. In addition, BoNT/A₁, B₁, E₁ and F₁ were successfully detected by immunological assays, unambiguously identified by mass spectrometric-based methods, and their specific activities were assigned by the mouse LD50 bioassay. The potencies of all six BoNT/A1-F1 were quantified by the ex vivo mouse phrenic nerve hemidiaphragm assay, allowing a direct comparison. In conclusion, highly pure recombinant BoNT reference materials were produced, thoroughly characterized and employed as spiking material in a worldwide BoNT proficiency test organized by the EQuATox consortium.

  7. 230Th-234U Model-Ages of Some Uranium Standard Reference Materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, R W; Gaffney, A M; Kristo, M J

    The 'age' of a sample of uranium is an important aspect of a nuclear forensic investigation and of the attribution of the material to its source. To the extent that the sample obeys the standard rules of radiochronometry, then the production ages of even very recent material can be determined using the {sup 230}Th-{sup 234}U chronometer. These standard rules may be summarized as (a) the daughter/parent ratio at time=zero must be known, and (b) there has been no daughter/parent fractionation since production. For most samples of uranium, the 'ages' determined using this chronometer are semantically 'model-ages' because (a) some assumptionmore » of the initial {sup 230}Th content in the sample is required and (b) closed-system behavior is assumed. The uranium standard reference materials originally prepared and distributed by the former US National Bureau of Standards and now distributed by New Brunswick Laboratory as certified reference materials (NBS SRM = NBL CRM) are good candidates for samples where both rules are met. The U isotopic standards have known purification and production dates, and closed-system behavior in the solid form (U{sub 3}O{sub 8}) may be assumed with confidence. We present here {sup 230}Th-{sup 234}U model-ages for several of these standards, determined by isotope dilution mass spectrometry using a multicollector ICP-MS, and compare these ages with their known production history.« less

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    R. L. VanHorn; N. L. Hampton; R. C. Morris

    This document presents reference material for conducting screening level ecological risk assessments (SLERAs)for the waste area groups (WAGs) at the Idaho National Engineering Laboratory. Included in this document are discussions of the objectives of and processes for conducting SLERAs. The Environmental Protection Agency ecological risk assessment framework is closely followed. Guidance for site characterization, stressor characterization, ecological effects, pathways of contaminant migration, the conceptual site model, assessment endpoints, measurement endpoints, analysis guidance, and risk characterization are included.

  9. BCLDP site environmental report for calendar year 1997 on radiological and nonradiological parameters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fry, J.

    1998-09-30

    Battelle Memorial Institute currently maintains its retired nuclear research facilities in a surveillance and maintenance (S and M) mode and continues decontamination and decommissioning (D and D) activities. The activities are referred to as the Battelle Columbus Laboratories Decommissioning Project (BCLDP). Operations reference in this report are performed in support of S and M and D and D activities. The majority of this report is devoted to discussion of the West Jefferson facility, because the source term at this facility is larger than the source term at Battelle`s King Avenue site. The contamination found at the King Avenue site consistsmore » of small amounts of residual radioactive material in solid form, which has become embedded or captured in nearby surfaces such as walls, floors, ceilings, drains, laboratory equipment, and soils. By the end of calendar year (CY) 1997, most remediation activities were completed at the King Avenue site. The contamination found at the West Jefferson site is the result of research and development activities with irradiated materials. During CY 1997, multiple tests at the West Jefferson Nuclear Sciences Area found no isotopes present above the minimum detectable activity (MDA) for air releases or for liquid discharges to Big Darby Creek. Data obtained from downstream sampling locations were statistically indistinguishable from background levels.« less

  10. Development of a standard reference material for Cr(vi) in contaminated soil

    USGS Publications Warehouse

    Nagourney, S.J.; Wilson, S.A.; Buckley, B.; Kingston, H.M.S.; Yang, S.-Y.; Long, S.E.

    2008-01-01

    Over the last several decades, considerable contamination by hexavalent chromium has resulted from the land disposal of Chromite Ore Processing Residue (COPR). COPR contains a number of hexavalent chromium-bearing compounds that were produced in high temperature industrial processes. Concern over the carcinogenic potential of this chromium species, and its environmental mobility, has resulted in efforts to remediate these waste sites. To provide support to analytical measurements of hexavalent chromium, a candidate National Institute of Standards and Technology (NIST) Standard Reference Material?? (SRM 2701), having a hexavalent chromium content of approximately 500 mg kg -1, has been developed using material collected from a waste site in Hudson County, New Jersey, USA. The collection, processing, preparation and preliminary physico-chemical characterization of the material are discussed. A two-phase multi-laboratory testing study was carried out to provide data on material homogeneity and to assess the stability of the material over the duration of the study. The study was designed to incorporate several United States Environmental Protection Agency (USEPA) determinative methods for hexavalent chromium, including Method 6800 which is based on speciated isotope dilution mass spectrometry (SIDMS), an approach which can account for chromium species inter-conversion during the extraction and measurement sequence. This journal is ?? The Royal Society of Chemistry 2008.

  11. The ecology of the soft-bottom benthos of San Francisco Bay: a community profile

    USGS Publications Warehouse

    Nichols, Frederic H.; Pamatmat, Mario M.

    1988-01-01

    The profile provides a reference to the scientific information concerning the animals and plants of the bay's benthic communities, their importance to the bay ecosystem, and their value as a resource measured in human terms. Because there have been few process-oriented studies of the benthos of San Francisco Bay (e.g., field and laboratory rate-measurement experiments), the material presented herein is largely descriptive. Nonetheless, we have described the processes that interconnect the various physical, chemical, and biological components of the benthic environment, and the important couplings between this environment and the water column above, with reference to research results from other estuaries where necessary. We consider the role of the benthic community as a food source for fish, aquatic birds, and humans; as a consumer or degrader of organic materials including wastes; as a recycler of minerals and nutrients; and as an accumulator of pollutants.

  12. The uncertainty of reference standards--a guide to understanding factors impacting uncertainty, uncertainty calculations, and vendor certifications.

    PubMed

    Gates, Kevin; Chang, Ning; Dilek, Isil; Jian, Huahua; Pogue, Sherri; Sreenivasan, Uma

    2009-10-01

    Certified solution standards are widely used in forensic toxicological, clinical/diagnostic, and environmental testing. Typically, these standards are purchased as ampouled solutions with a certified concentration. Vendors present concentration and uncertainty differently on their Certificates of Analysis. Understanding the factors that impact uncertainty and which factors have been considered in the vendor's assignment of uncertainty are critical to understanding the accuracy of the standard and the impact on testing results. Understanding these variables is also important for laboratories seeking to comply with ISO/IEC 17025 requirements and for those preparing reference solutions from neat materials at the bench. The impact of uncertainty associated with the neat material purity (including residual water, residual solvent, and inorganic content), mass measurement (weighing techniques), and solvent addition (solution density) on the overall uncertainty of the certified concentration is described along with uncertainty calculations.

  13. Comprehensive HPTLC Fingerprinting for Quality Control of an Herbal Drug - The Case of Angelica gigas Root.

    PubMed

    Frommenwiler, Débora Arruda; Kim, Jonghwan; Yook, Chang-Soo; Tran, Thi Thu Trang; Cañigueral, Salvador; Reich, Eike

    2018-04-01

    The quality of herbal drugs is usually controlled using several tests recommended in a monograph. HPTLC is the method of choice for identification in many pharmacopoeias. If combined with a suitable reference material for comparison, HPTLC can provide information beyond identification and thus may simplify quality control. This paper describes, as a proof of concept, how HPTLC can be applied to define specifications for an herbal reference material and to control the quality of an herbal drug according to these specifications. Based on multiple batches of cultivated Angelica gigas root, a specific HPTLC method for identification was optimized. This method can distinguish 27 related species. It also can detect the presence of mixtures of A. gigas with two other Angelica species traded as "Dang gui" and is suitable as well for quantitative assessment of samples in a test for minimum content of the sum of decursin and decursinol angelate. The new concept of "comprehensive HPTLC fingerprinting" is proposed: HPTLC fingerprints (images), which are used for identification, are converted into peak profiles and the intensities of selected zones are quantitatively compared to those of the corresponding zones of the reference material. Following a collaborative trial involving three laboratories in three countries, the method was applied to check the quality of further candidates for establishing an appropriate reference material. In conclusion, this case demonstrates that a single HPTLC analysis can provide information about identity, purity, and minimum content of markers of an herbal drug. Georg Thieme Verlag KG Stuttgart · New York.

  14. Preparation and certification of Re-Os dating reference materials: Molybdenites HLP and JDC

    USGS Publications Warehouse

    Du, A.; Wu, S.; Sun, D.; Wang, Shaoming; Qu, W.; Markey, R.; Stain, H.; Morgan, J.; Malinovskiy, D.

    2004-01-01

    Two Re-Os dating reference material molybdenites were prepared. Molybdenite JDC and molybdenite HLP are from a carbonate vein-type molybdenum-(lead)- uranium deposit in the Jinduicheng-Huanglongpu area of Shaanxi province, China. The samples proved to be homogeneous, based on the coefficient of variation of analytical results and an analysis of variance test. The sampling weight was 0.1 g for JDC and 0.025 g for HLP. An isotope dilution method was used for the determination of Re and Os. Sample decomposition and preconcentration of Re and Os prior to measurement were accomplished using a variety of methods: acid digestion, alkali fusion, ion exchange and solvent extraction. Negative thermal ionisation mass spectrometry and inductively coupled plasma-mass spectrometry were used for the determination of Re and 187Os concentration and isotope ratios. The certified values include the contents of Re and Os and the model ages. For HLP, the Re content was 283.8 ?? 6.2 ??g g-1, 187Os was 659 ?? 14 ng g-1 and the Re-Os model age was 221.4 ?? 5.6 Ma. For JDC, the Re content was 17.39 ?? 0.32 ng g-1, 187Os was 25.46 ?? 0.60 ng g-1 and the Re-Os model age was 139.6 ?? 3.8 Ma. Uncertainties for both certified reference materials are stated at the 95% level of confidence. Three laboratories (from three countries: P.R. China, USA, Sweden) joined in the certification programme. These certified reference materials are primarily useful for Re-Os dating of molybdenite, sulfides, black shale, etc.

  15. Transport equations of electrodiffusion processes in the laboratory reference frame.

    PubMed

    Garrido, Javier

    2006-02-23

    The transport equations of electrodiffusion processes use three reference frames for defining the fluxes: Fick's reference in diffusion, solvent-fixed reference in transference numbers, and laboratory fluxes in electric conductivity. The convenience of using only one reference frame is analyzed here from the point of view of the thermodynamics of irreversible processes. A relation between the fluxes of ions and solvent and the electric current density is deduced first from a mass and volume balance. This is then used to show that (i) the laboratory and Fick's diffusion coefficients are identical and (ii) the transference numbers of both the solvent and the ion in the laboratory reference frame are related. Finally, four experimental methods for the measurement of ion transference numbers are analyzed critically. New expressions for evaluating transference numbers for the moving boundary method and the chronopotentiometry technique are deduced. It is concluded that the ion transport equation in the laboratory reference frame plays a key role in the description of electrodiffusion processes.

  16. Non-structural carbohydrates in woody plants compared among laboratories.

    PubMed

    Quentin, Audrey G; Pinkard, Elizabeth A; Ryan, Michael G; Tissue, David T; Baggett, L Scott; Adams, Henry D; Maillard, Pascale; Marchand, Jacqueline; Landhäusser, Simon M; Lacointe, André; Gibon, Yves; Anderegg, William R L; Asao, Shinichi; Atkin, Owen K; Bonhomme, Marc; Claye, Caroline; Chow, Pak S; Clément-Vidal, Anne; Davies, Noel W; Dickman, L Turin; Dumbur, Rita; Ellsworth, David S; Falk, Kristen; Galiano, Lucía; Grünzweig, José M; Hartmann, Henrik; Hoch, Günter; Hood, Sharon; Jones, Joanna E; Koike, Takayoshi; Kuhlmann, Iris; Lloret, Francisco; Maestro, Melchor; Mansfield, Shawn D; Martínez-Vilalta, Jordi; Maucourt, Mickael; McDowell, Nathan G; Moing, Annick; Muller, Bertrand; Nebauer, Sergio G; Niinemets, Ülo; Palacio, Sara; Piper, Frida; Raveh, Eran; Richter, Andreas; Rolland, Gaëlle; Rosas, Teresa; Saint Joanis, Brigitte; Sala, Anna; Smith, Renee A; Sterck, Frank; Stinziano, Joseph R; Tobias, Mari; Unda, Faride; Watanabe, Makoto; Way, Danielle A; Weerasinghe, Lasantha K; Wild, Birgit; Wiley, Erin; Woodruff, David R

    2015-11-01

    Non-structural carbohydrates (NSC) in plant tissue are frequently quantified to make inferences about plant responses to environmental conditions. Laboratories publishing estimates of NSC of woody plants use many different methods to evaluate NSC. We asked whether NSC estimates in the recent literature could be quantitatively compared among studies. We also asked whether any differences among laboratories were related to the extraction and quantification methods used to determine starch and sugar concentrations. These questions were addressed by sending sub-samples collected from five woody plant tissues, which varied in NSC content and chemical composition, to 29 laboratories. Each laboratory analyzed the samples with their laboratory-specific protocols, based on recent publications, to determine concentrations of soluble sugars, starch and their sum, total NSC. Laboratory estimates differed substantially for all samples. For example, estimates for Eucalyptus globulus leaves (EGL) varied from 23 to 116 (mean = 56) mg g(-1) for soluble sugars, 6-533 (mean = 94) mg g(-1) for starch and 53-649 (mean = 153) mg g(-1) for total NSC. Mixed model analysis of variance showed that much of the variability among laboratories was unrelated to the categories we used for extraction and quantification methods (method category R(2) = 0.05-0.12 for soluble sugars, 0.10-0.33 for starch and 0.01-0.09 for total NSC). For EGL, the difference between the highest and lowest least squares means for categories in the mixed model analysis was 33 mg g(-1) for total NSC, compared with the range of laboratory estimates of 596 mg g(-1). Laboratories were reasonably consistent in their ranks of estimates among tissues for starch (r = 0.41-0.91), but less so for total NSC (r = 0.45-0.84) and soluble sugars (r = 0.11-0.83). Our results show that NSC estimates for woody plant tissues cannot be compared among laboratories. The relative changes in NSC between treatments measured within a laboratory may be comparable within and between laboratories, especially for starch. To obtain comparable NSC estimates, we suggest that users can either adopt the reference method given in this publication, or report estimates for a portion of samples using the reference method, and report estimates for a standard reference material. Researchers interested in NSC estimates should work to identify and adopt standard methods. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Determination of osmium concentrations and (187)Os/(188)Os of crude oils and source rocks by coupling high-pressure, high-temperature digestion with sparging OsO(4) into a multicollector inductively coupled plasma mass spectrometer.

    PubMed

    Sen, Indra S; Peucker-Ehrenbrink, Bernhard

    2014-03-18

    The (187)Os/(188)Os ratio that is based on the β(-)-decay of (187)Re to (187)Os (t1/2 = 41.6 billion years) is widely used to investigate petroleum system processes. Despite its broad applicability to studies of hydrocarbon deposits worldwide, a suitable matrix-matched reference material for Os analysis does not exist. In this study, a method that enables Os isotope measurement of crude oil with in-line Os separation and purification from the sample matrix is proposed. The method to analyze Os concentration and (187)Os/(187)Os involves sample digestion under high pressure and high temperature using a high pressure asher (HPA-S, Anton Paar), sparging of volatile osmium tetroxide from the sample solution, and measurements using multicollector inductively coupled plasma mass spectrometry (MC-ICPMS). This methods significantly reduced the total procedural time compared to conventional Carius tube digestion followed by Os separation and purification using solvent extraction, microdistillation and N-TIMS analysis. The method yields Os concentration (28 ± 4 pg g(-1)) and (187)Os/(188)Os (1.62 ± 0.15) of commercially available crude oil reference material NIST 8505 (1 S.D., n = 6). The reference material NIST 8505 is homogeneous with respect to Os concentration at a test portion size of 0.2 g. Therefore, (187)Os/(188)Os composition and Os concentration of NIST 8505 can serve as a matrix-matched reference material for Os analysis. Data quality was assessed by repeated measurements of the USGS shale reference material SCo-1 (sample matrix similar to petroleum source rock) and the widely used Liquid Os Standard solution (LOsSt). The within-laboratory reproducibility of (187)Os/(188)Os for a 5 pg of LOsSt solution, analyzed with this method over a period of 12 months was ∼1.4% (1 S.D., n = 26), respectively.

  18. Development of the Ion Exchange-Gravimetric Method for Sodium in Serum as a Definitive Method

    PubMed Central

    Moody, John R.; Vetter, Thomas W.

    1996-01-01

    An ion exchange-gravimetric method, previously developed as a National Committee for Clinical Laboratory Standards (NCCLS) reference method for the determination of sodium in human serum, has been re-evaluated and improved. Sources of analytical error in this method have been examined more critically and the overall uncertainties decreased. Additionally, greater accuracy and repeatability have been achieved by the application of this definitive method to a sodium chloride reference material. In this method sodium in serum is ion-exchanged, selectively eluted and converted to a weighable precipitate as Na2SO4. Traces of sodium eluting before or after the main fraction, and precipitate contaminants are determined instrumentally. Co-precipitating contaminants contribute less than 0.1 % while the analyte lost to other eluted ion-exchange fractions contributes less than 0.02 % to the total precipitate mass. With improvements, the relative expanded uncertainty (k = 2) of the method, as applied to serum, is 0.3 % to 0.4 % and is less than 0.1 % when applied to a sodium chloride reference material. PMID:27805122

  19. Laboratory measurements of gravel thermal properties. A methodology proposal

    NASA Astrophysics Data System (ADS)

    Cultrera, Matteo; Peron, Fabio; Bison, Paolo; Dalla Santa, Giorgia; Bertermann, David; Muller, Johannes; Bernardi, Adriana; Galgaro, Antonio

    2017-04-01

    Gravel thermal properties measurements at laboratory level is quite challenging due to several technical and logistic issues, mainly connected to the sediment sizes and the variability of their mineralogical composition. The direct measurement of gravel thermal properties usually are not able to involve a representative volume of geological material, consequently the thermal measurements performed produce much dispersed results and not consistent due to the large interstitial voids and the poor physical contact with the measuring sensors. With the aim of directly provide the measurement of the gravel thermal properties, a new methodology has been developed and some results are already available on several gravel deposits samples around Europe. Indeed, a single guarded hot plate Taurus Instruments TLP 800 measured the gravel thermal properties. Some instrumental adjustments were necessary to adapt the measuring devices and to finalize the thermal measurements on gravels at the IUAV FISTEC laboratory (Environmental Technical Physics Laboratory of Venice University). This device usually provides thermal measurements according to ISO 8302, ASTM C177, EN 1946-2, EN 12664, EN 12667 and EN 12939 for building materials. A preliminary calibration has been performed comparing the outcomes obtained with the single guarded hot plate with a needle probe of a portable thermal conductivity meter (ISOMET). Standard sand (ISO 67:2009) is used as reference material. This study is provided under the Cheap-GSHPs project that has received funding from the European Union's Horizon 2020 research and innovation program under grant agreement no. 657982

  20. Attenuation Drift in the Micro-Computed Tomography System at LLNL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dooraghi, Alex A.; Brown, William; Seetho, Isaac

    2016-01-12

    The maximum allowable level of drift in the linear attenuation coefficients (μ) for a Lawrence Livermore National Laboratory (LLNL) micro-computed tomography (MCT) system was determined to be 0.1%. After ~100 scans were acquired during the period of November 2014 to March 2015, the drift in μ for a set of six reference materials reached or exceeded 0.1%. Two strategies have been identified to account for or correct the drift. First, normalizing the 160 kV and 100 kV μ data by the μ of water at the corresponding energy, in contrast to conducting normalization at the 160 kV energy only, significantlymore » compensates for measurement drift. Even after the modified normalization, μ of polytetrafluoroethylene (PTFE) increases linearly with scan number at an average rate of 0.00147% per scan. This is consistent with PTFE radiation damage documented in the literature. The second strategy suggested is the replacement of the PTFE reference with fluorinated ethylene propylene (FEP), which has the same effective atomic number (Ze) and electron density (ρe) as PTFE, but is 10 times more radiation resistant. This is important as effective atomic number and electron density are key parameters in analysis. The presence of a material with properties such as PTFE, when taken together with the remaining references, allows for a broad range of the (Ze, ρe) feature space to be used in analysis. While FEP is documented as 10 times more radiation resistant, testing will be necessary to assess how often, if necessary, FEP will need to be replaced. As radiation damage to references has been observed, it will be necessary to monitor all reference materials for radiation damage to ensure consistent x-ray characteristics of the references.« less

  1. Geoengineering characterization of welded tuffs from laboratory and field investigations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zimmerman, R.M.; Nimick, F.B.; Board, M.P.

    1984-12-31

    Welded tuff beneath Yucca Mountain adjacent to the Nevada Test Site (NTS) is being considered for development as a high-level radioactive waste repository by the Nevada Nuclear Waste Storage Investigations (NNWSI) Project. Because access into Yucca Mountain has been limited to borehole explorations, early geoengineering materials characterizations have been derived from laboratory tests on cores from Yucca Mountain and from laboratory and field tests on welded tuffs located in G-Tunnel on the NTS. G-Tunnel contains welded tuffs that have similar properties and stress states to those at Yucca Mountain and has been the location for in situ rock mechanics testing.more » The purpose of this paper is to summarize the geoengineering material property data obtained to date and to compare appropriate laboratory and field data from G-Tunnel to findings from Yucca Mountain. Geomechanical and thermal data are provided and are augmented by limited geological and hydrological data. A comparison of results of laboratory measurements on tuffs from Yucca Mountain and G-Tunnel indicates good agreement between the bulk densities, saturations, moduli of elasticity, Poisson`s ratios, and P-wave velocities. The G-Tunnel tuff has slightly lower thermal conductivity, tensile strength, compressive strength and slightly higher matrix permeability than does the welded tuff near the proposed repository horizon at Yucca Mountain. From a laboratory-to-field scaling perspective, the modulus of deformation shows the most sensitivity to field conditions because of the presence of the joints found in the field. 14 references, 1 table.« less

  2. [Assessment of a supervision grid being used in the laboratories of cutaneous leishmaniasis in Morocco].

    PubMed

    El Mansouri, Bouchra; Amarir, Fatima; Hajli, Yamina; Fellah, Hajiba; Sebti, Faiza; Delouane, Bouchra; Sadak, Abderrahim; Adlaoui, El Bachir; Rhajaoui, Mohammed

    2017-01-01

    The aim of our study was to assess a standardized supervisory grid as a new supervision tool being used in the laboratories of leishmaniasis. We conducted a pilot trial to evaluate the ongoing performances of seven provincial laboratories, in four provinces in Morocco, over a period of two years, between 2006 and 2014. This study detailed the situation in provincial laboratories before and after the implementation of the supervisory grid. A total of twenty-one grids were analyzed. In 2006, the results clearly showed a poor performance of laboratories: need for training (41.6%), staff performing skin biopsy (25%), shortage of materials and reagents (65%), non-compliant document and local management (85%). Several corrective actions were conducted by the National Reference Laboratory (LNRL) of Leishmaniasis during the study period. In 2014, the LNRL recorded a net improvement of the performances of the laboratories. The need for training, the quality of the biopsy, the supply of tools and reagents were met and an effective coordination activity was established between the LNRL and the provincial laboratories. This trial shows the effectiveness of the grid as a high quality supervisory tool and as a cornerstone of making progress on fight programs against leishmaniases.

  3. Round robin test on quantification of amyloid-β 1-42 in cerebrospinal fluid by mass spectrometry.

    PubMed

    Pannee, Josef; Gobom, Johan; Shaw, Leslie M; Korecka, Magdalena; Chambers, Erin E; Lame, Mary; Jenkins, Rand; Mylott, William; Carrillo, Maria C; Zegers, Ingrid; Zetterberg, Henrik; Blennow, Kaj; Portelius, Erik

    2016-01-01

    Cerebrospinal fluid (CSF) amyloid-β 1-42 (Aβ42) is an important biomarker for Alzheimer's disease, both in diagnostics and to monitor disease-modifying therapies. However, there is a great need for standardization of methods used for quantification. To overcome problems associated with immunoassays, liquid chromatography-tandem mass spectrometry (LC-MS/MS) has emerged as a critical orthogonal alternative. We compared results for CSF Aβ42 quantification in a round robin study performed in four laboratories using similar sample preparation methods and LC-MS instrumentation. The LC-MS results showed excellent correlation between laboratories (r(2) >0.98), high analytical precision, and good correlation with enzyme-linked immunosorbent assay (r(2) >0.85). The use of a common reference sample further decreased interlaboratory variation. Our results indicate that LC-MS is suitable for absolute quantification of Aβ42 in CSF and highlight the importance of developing a certified reference material. Copyright © 2016 The Alzheimer's Association. Published by Elsevier Inc. All rights reserved.

  4. An overview of quality control practices in Ontario with particular reference to cholesterol analysis.

    PubMed

    Krishnan, S; Webb, S; Henderson, A R; Cheung, C M; Nazir, D J; Richardson, H

    1999-03-01

    The Laboratory Proficiency Testing Program (LPTP) assesses the analytical performance of all licensed laboratories in Ontario. The LPTP Enzymes, Cardiac Markers, and Lipids Committee conducted a "Patterns of Practice" survey to assess the in-house quality control (QC) practices of laboratories in Ontario using cholesterol as the QC paradigm. The survey was questionnaire-based seeking information on statistical calculations, software rules, review process and data retention, and so on. Copies of the in-house cholesterol QC graphs were requested. A total of 120 of 210 laboratories were randomly chosen to receive the questionnaires during 1995 and 1996; 115 laboratories responded, although some did not answer all questions. The majority calculate means and standard deviations (SD) every month, using anywhere from 4 to >100 data points. 65% use a fixed mean and SD, while 17% use means calculated from the previous month. A few use a floating or cumulative mean. Some laboratories that do not use fixed means use a fixed SD. About 90% use some form of statistical quality control rules. The most common rules used to detect random error are 1(3s)/R4s while 2(2s)/4(1s)/10x are used for systematic errors. About 20% did not assay any QC at levels >5.5 mmol/L. Quality control data are reviewed daily (technologists), weekly and monthly (supervisors/directors). Most laboratories retain their QC records for up to 3 years on paper and magnetic media. On some QC graphs the mean and SD, QC product lot number, or reference to action logs are not apparent. Quality control practices in Ontario are, therefore, disappointing. Improvement is required in the use of clinically appropriate concentrations of QC material and documentation on QC graphs.

  5. GHR1 - A new Eocene natural reference material for U-Pb and Hf isotopic measurements in zircon

    NASA Astrophysics Data System (ADS)

    Ibanez-Mejia, M.; Eddy, M. P.

    2017-12-01

    We present chemical abrasion-isotope dilution-thermal ionization (CA-ID-TIMS) U-Pb zircon geochronology and solution multicollector-inductively coupled plasma-mass spectrometry (MC-ICP-MS) Hf isotopic data from a proposed natural zircon reference material for use during in situ analyses of U-Pb and Hf isotopic ratios. The sample, GHR1, was collected from the rapakivi intrusive phase of the Eocene Golden Horn batholith in Washington, USA. Zircons separated from this sample range up to 250-300 μm in length and have moderate aspect ratios. A weighted mean of 15 Th-corrected 206Pb/238U zircon dates from GHR1 produced at the Massachusetts Institute of Technology is 48.132 ± 0.023 Ma (2σ analytical and tracer uncertainties only, MSWD=1.70) confirming that there is little or no inter-crystal age heterogeneity at the scale of a few 10 kyr. Solution MC-ICP-MS measurements of chemically purified aliquots give a 176Hf/177Hf weighted mean of 0.283050 ± 17 (2σ, n=10), corresponding to a ɛHf0 of ca. +9.3. The 2σ variability of these measurements is comparable to our reproducibility of the JMC-475 Hf isotopic standard 0.282160 ± 14 (n= 13), suggesting that GHR1 zircons are homogenous with respect to 176Hf/177Hf. In situ 206Pb/238U dates from collaborating secondary ion mass spectrometry (SIMS), sensitive high-resolution ion microprobe (SHRIMP), and laser ablation ICP-MS (LA-ICP-MS) laboratories are in excellent agreement with the CA-ID-TIMS date and illustrate the reproducibility and potential value of this reference zircon. The mean values of 176Hf/177Hf measurements from two LA-ICP-MS laboratories are in agreement with the solution MC-ICP-MS value, but show slightly greater dispersion and higher (Lu+Yb)/Hf values. We attribute this discrepancy to apatite inclusions that are high in REE and may lead to greater isobaric interferences on 176Hf. These inclusions and potential isobaric interferences from REE were removed during the chemical abrasion step prior to bulk dissolution and ion-exchange purification in the solution data. Nevertheless, the apparent isotopic homogeneity and reproducibility of 206Pb/238U and 176Hf/177Hf ratios and the potentially unlimited reserves of GHR1 suggest that it is a promising reference material. We plan to distribute GHR1 at the meeting to interested laboratories.

  6. Verification of an immunoturbidimetric assay for heart-type fatty acid-binding protein (H-FABP) on a clinical chemistry platform and establishment of the upper reference limit.

    PubMed

    Da Molin, Simona; Cappellini, Fabrizio; Falbo, Rosanna; Signorini, Stefano; Brambilla, Paolo

    2014-11-01

    Heart-type fatty acid-binding protein (H-FABP) is an early biomarker of cardiac injury. Randox Laboratories developed an immunoturbidimetric H-FABP assay for non-proprietary automated clinical chemistry analysers that could be useful in the emergency department. We verified the analytical performances claimed by Randox Laboratories on Roche Cobas 6000 clinical chemistry platform in use in our laboratory, and we defined our own 99th percentile upper reference limit for H-FABP. For the verification of method performances, we used pools of spared patient samples from routine and two levels of quality control material, while samples for the reference value study were collected from 545 blood donors. Following CLSI guidelines we verified limit of blank (LOB), limit of detection (LOD), limit of quantitation (LOQ), repeatability and within-laboratory precision, trueness, linearity, and the stability of H-FABP in EDTA over 24h. The LOQ (3.19 μg/L) was verified with a CV% of 10.4. The precision was verified for the low (mean 5.88 μg/L, CV=6.7%), the medium (mean 45.28 μg/L, CV=3.0%), and the high concentration (mean 88.81 μg/L, CV=4.0%). The trueness was verified as well as the linearity over the indicated measurement interval of 0.747-120 μg/L. The H-FABP in EDTA samples is stable throughout 24h both at room temperature and at 4 °C. The H-FABP 99th percentile upper reference limit for all subjects (3.60 μg/L, 95% CI 3.51-3.77) is more appropriate than gender-specific ones that are not statistically different. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  7. Evaluation of a laboratory quality assurance pilot programme for malaria diagnostics in low-transmission areas of Kenya, 2013.

    PubMed

    Wanja, Elizabeth; Achilla, Rachel; Obare, Peter; Adeny, Rose; Moseti, Caroline; Otieno, Victor; Morang'a, Collins; Murigi, Ephantus; Nyamuni, John; Monthei, Derek R; Ogutu, Bernhards; Buff, Ann M

    2017-05-25

    One objective of the Kenya National Malaria Strategy 2009-2017 is scaling access to prompt diagnosis and effective treatment. In 2013, a quality assurance (QA) pilot was implemented to improve accuracy of malaria diagnostics at selected health facilities in low-transmission counties of Kenya. Trends in malaria diagnostic and QA indicator performance during the pilot are described. From June to December 2013, 28 QA officers provided on-the-job training and mentoring for malaria microscopy, malaria rapid diagnostic tests and laboratory QA/quality control (QC) practices over four 1-day visits at 83 health facilities. QA officers observed and recorded laboratory conditions and practices and cross-checked blood slides for malaria parasite presence, and a portion of cross-checked slides were confirmed by reference laboratories. Eighty (96%) facilities completed the pilot. Among 315 personnel at pilot initiation, 13% (n = 40) reported malaria diagnostics training within the previous 12 months. Slide positivity ranged from 3 to 7%. Compared to the reference laboratory, microscopy sensitivity ranged from 53 to 96% and positive predictive value from 39 to 53% for facility staff and from 60 to 96% and 52 to 80%, respectively, for QA officers. Compared to reference, specificity ranged from 88 to 98% and negative predictive value from 98 to 99% for health-facility personnel and from 93 to 99% and 99%, respectively, for QA officers. The kappa value ranged from 0.48-0.66 for facility staff and 0.57-0.84 for QA officers compared to reference. The only significant test performance improvement observed for facility staff was for specificity from 88% (95% CI 85-90%) to 98% (95% CI 97-99%). QA/QC practices, including use of positive-control slides, internal and external slide cross-checking and recording of QA/QC activities, all increased significantly across the pilot (p < 0.001). Reference material availability also increased significantly; availability of six microscopy job aids and seven microscopy standard operating procedures increased by a mean of 32 percentage points (p < 0.001) and 38 percentage points (p < 0.001), respectively. Significant gains were observed in malaria QA/QC practices over the pilot. However, these advances did not translate into improved accuracy of malaria diagnostic performance perhaps because of the limited duration of the QA pilot implementation.

  8. Traceability Assessment and Performance Evaluation of Results for Measurement of Abbott Clinical Chemistry Assays on 4 Chemistry Analyzers.

    PubMed

    Lim, Jinsook; Song, Kyung Eun; Song, Sang Hoon; Choi, Hyun-Jung; Koo, Sun Hoe; Kwon, Gye Choel

    2016-05-01

    -The traceability of clinical results to internationally recognized and accepted reference materials and reference measurement procedures has become increasingly important. Therefore, the establishment of traceability has become a mandatory requirement for all in vitro diagnostics devices. -To evaluate the traceability of the Abbott Architect c8000 system (Abbott Laboratories, Abbott Park, Illinois), consisting of calibrators and reagents, across 4 different chemistry analyzers, and to evaluate its general performance on the Toshiba 2000FR NEO (Toshiba Medical Systems Corporation, Otawara-shi, Tochigi-ken, Japan). -For assessment of traceability, secondary reference materials were evaluated 5 times, and then bias was calculated. Precision, linearity, and carryover were determined according to the guidelines of the Clinical and Laboratory Standards Institute (Wayne, Pennsylvania). -The biases from 4 different analyzers ranged from -2.33% to 2.70% on the Toshiba 2000FR NEO, -2.33% to 5.12% on the Roche Hitachi 7600 (Roche Diagnostics International, Basel, Switzerland), -0.93% to 2.87% on the Roche Modular, and -2.16% to 2.86% on the Abbott Architect c16000. The total coefficients of variance of all analytes were less than 5%. The coefficients of determination (R(2)) were more than 0.9900. The carryover rate ranged from -0.54% to 0.17%. -Abbott clinical chemistry assays met the performance criteria based on desirable biological variation for precision, bias, and total error. They also showed excellent linearity and carryover. Therefore, these clinical chemistry assays were found to be accurate and reliable and are readily applicable on the various platforms used in this study.

  9. Orsphere: Physics Measurments For Bare, HEU(93.2)-Metal Sphere

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marshall, Margaret A.; Bess, John D.; Briggs, J. Blair

    In the early 1970s Dr. John T. Mihalczo (team leader), J.J. Lynn, and J.R. Taylor performed experiments at the Oak Ridge Critical Experiments Facility (ORCEF) with highly enriched uranium (HEU) metal (called Oak Ridge Alloy or ORALLOY) in an attempt to recreate GODIVA I results with greater accuracy than those performed at Los Alamos National Laboratory in the 1950s (HEU-MET-FAST-001). The purpose of the Oak Ridge ORALLOY Sphere (ORSphere) experiments was to estimate the unreflected and unmoderated critical mass of an idealized sphere of uranium metal corrected to a density, purity, and enrichment such that it could be compared withmore » the GODIVA I experiments. “The very accurate description of this sphere, as assembled, establishes it as an ideal benchmark for calculational methods and cross-section data files” (Reference 1). While performing the ORSphere experiments care was taken to accurately document component dimensions (±0.0001 inches), masses (±0.01 g), and material data. The experiment was also set up to minimize the amount of structural material in the sphere proximity. Two, correlated spheres were evaluated and judged to be acceptable as criticality benchmark experiments. This evaluation is given in HEU-MET-FAST-100. The second, smaller sphere was used for additional reactor physics measurements. Worth measurements (Reference 1, 2, 3 and 4), the delayed neutron fraction (Reference 3, 4 and 5) and surface material worth coefficient (Reference 1 and 2) are all measured and judged to be acceptable as benchmark data. The prompt neutron decay (Reference 6), relative fission density (Reference 7) and relative neutron importance (Reference 7) were measured, but are not evaluated. Information for the evaluation was compiled from References 1 through 7, the experimental logbooks 8 and 9 ; additional drawings and notes provided by the experimenter; and communication with the lead experimenter, John T. Mihalczo.« less

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marshall, Margaret A.

    In the early 1970s Dr. John T. Mihalczo (team leader), J.J. Lynn, and J.R. Taylor performed experiments at the Oak Ridge Critical Experiments Facility (ORCEF) with highly enriched uranium (HEU) metal (called Oak Ridge Alloy or ORALLOY) in an attempt to recreate GODIVA I results with greater accuracy than those performed at Los Alamos National Laboratory in the 1950s (HEU-MET-FAST-001). The purpose of the Oak Ridge ORALLOY Sphere (ORSphere) experiments was to estimate the unreflected and unmoderated critical mass of an idealized sphere of uranium metal corrected to a density, purity, and enrichment such that it could be compared withmore » the GODIVA I experiments. “The very accurate description of this sphere, as assembled, establishes it as an ideal benchmark for calculational methods and cross-section data files” (Reference 1). While performing the ORSphere experiments care was taken to accurately document component dimensions (±0.0001 inches), masses (±0.01 g), and material data. The experiment was also set up to minimize the amount of structural material in the sphere proximity. Two, correlated spheres were evaluated and judged to be acceptable as criticality benchmark experiments. This evaluation is given in HEU-MET-FAST-100. The second, smaller sphere was used for additional reactor physics measurements. Worth measurements (Reference 1, 2, 3 and 4), the delayed neutron fraction (Reference 3, 4 and 5) and surface material worth coefficient (Reference 1 and 2) are all measured and judged to be acceptable as benchmark data. The prompt neutron decay (Reference 6), relative fission density (Reference 7) and relative neutron importance (Reference 7) were measured, but are not evaluated. Information for the evaluation was compiled from References 1 through 7, the experimental logbooks 8 and 9 ; additional drawings and notes provided by the experimenter; and communication with the lead experimenter, John T. Mihalczo.« less

  11. The need for accurate total cholesterol measurement. Recommended analytical goals, current state of reliability, and guidelines for better determinations.

    PubMed

    Naito, H K

    1989-03-01

    We have approached a dawn of a new era in detection, evaluation, treatment, and monitoring of individuals with elevated blood cholesterol levels who are at increased risk for CHD. The NHLBI's National Cholesterol Education Program will be the major force underlying this national awareness program, which is dependent on the clinical laboratories providing reliable data. Precision or reproducibility of results is not a problem for most of the laboratories, but accuracy is a major concern. Both the manufacturers and laboratorians need to standardize the measurement for cholesterol so that the accuracy base is traceable to the NCCLS NRS/CHOL. The manufacturers need to adopt a uniform policy that will ensure that the values assigned to calibration, quality control, and quality assurance or survey materials are accurate and traceable to the NCCLS/CHOL. Since, at present, there are some limitations of these materials caused by matrix effects, laboratories are encouraged to use the CDC-NHLBI National Reference Laboratory Network to evaluate and monitor their ability to measure patient blood cholesterol levels accurately. Major areas of analytical problems are identified and general, as well as specific, recommendations are provided to help ensure reliable measurement of cholesterol in patient specimens.

  12. New Brunswick Laboratory progress report, October 1989--September 1990

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The New Brunswick Laboratory (NBL) has been tasked by the DOE Office of Safeguards and Security, Defense Programs (OSS/DP) to assure the application of accurate and reliable measurement technology for the safeguarding of special nuclear materials. NBL is fulfilling its mission responsibilities by identifying the measurement and measurement-related needs of the nuclear material safeguards community and addressing them by means of activities in the following program areas: (1) reference and calibration materials, (2) measurement development, (3) measurement services, (4) measurement evaluation, (5) safeguards assessment, and (6) site-specific assistance. Highlights of each of these program areas are provided in this summary.more » This progress report is written as a part of NBL's technology transfer responsibilities, primarily for the use and benefit of the scientific personnel that perform safeguards-related measurements. Consequently, the report is technical in nature. Many of the reports of multi-year projects are fragmentary in that only partial results are reported. Separate topical reports are to be issued at the completion of many of these projects. 30 refs.« less

  13. Absolute Salinity, ''Density Salinity'' and the Reference-Composition Salinity Scale: present and future use in the seawater standard TEOS-10

    NASA Astrophysics Data System (ADS)

    Wright, D. G.; Pawlowicz, R.; McDougall, T. J.; Feistel, R.; Marion, G. M.

    2011-01-01

    Salinity plays a key role in the determination of the thermodynamic properties of seawater and the new TEOS-101 standard provides a consistent and effective approach to dealing with relationships between salinity and these thermodynamic properties. However, there are a number of practical issues that arise in the application of TEOS-10, both in terms of accuracy and scope, including its use in the reduction of field data and in numerical models. First, in the TEOS-10 formulation for IAPSO Standard Seawater, the Gibbs function takes the Reference Salinity as its salinity argument, denoted SR, which provides a measure of the mass fraction of dissolved material in solution based on the Reference Composition approximation for Standard Seawater. We discuss uncertainties in both the Reference Composition and the Reference-Composition Salinity Scale on which Reference Salinity is reported. The Reference Composition provides a much-needed fixed benchmark but modified reference states will inevitably be required to improve the representation of Standard Seawater for some studies. However, the Reference-Composition Salinity Scale should remain unaltered to provide a stable representation of salinity for use with the TEOS-10 Gibbs function and in climate change detection studies. Second, when composition anomalies are present in seawater, no single salinity variable can fully represent the influence of dissolved material on the thermodynamic properties of seawater. We consider three distinct representations of salinity that have been used in previous studies and discuss the connections and distinctions between them. One of these variables provides the most accurate representation of density possible as well as improvements over Reference Salinity for the determination of other thermodynamic properties. It is referred to as "Density Salinity" and is represented by the symbol SAdens; it stands out as the most appropriate representation of salinity for use in dynamical physical oceanography. The other two salinity variables provide alternative measures of the mass fraction of dissolved material in seawater. "Solution Salinity", denoted SAsoln, is the most obvious extension of Reference Salinity to allow for composition anomalies; it provides a direct estimate of the mass fraction of dissolved material in solution. "Added-Mass Salinity", denoted SAadd, is motivated by a method used to report laboratory experiments; it represents the component of dissolved material added to Standard Seawater in terms of the mass of material before it enters solution. We also discuss a constructed conservative variable referred to as "Preformed Salinity", denoted S∗, which will be useful in process-oriented numerical modelling studies. Finally, a conceptual framework for the incorporation of composition anomalies in numerical models is presented that builds from studies in which composition anomalies are simply ignored up to studies in which the influences of composition anomalies are accounted for using the results of biogeochemical models. 1TEOS-10: international Thermodynamic Equation of Seawater 2010, http://www.teos-10.org/.

  14. Absolute Salinity, "Density Salinity" and the Reference-Composition Salinity Scale: present and future use in the seawater standard TEOS-10

    NASA Astrophysics Data System (ADS)

    Wright, D. G.; Pawlowicz, R.; McDougall, T. J.; Feistel, R.; Marion, G. M.

    2010-08-01

    Salinity plays a key role in the determination of the thermodynamic properties of seawater and the new TEOS-101 standard provides a consistent and effective approach to dealing with relationships between salinity and these thermodynamic properties. However, there are a number of practical issues that arise in the application of TEOS-10, both in terms of accuracy and scope, including its use in the reduction of field data and in numerical models. First, in the TEOS-10 formulation for IAPSO Standard Seawater, the Gibbs function takes the Reference Salinity as its salinity argument, denoted SR, which provides a measure of the mass fraction of dissolved material in solution based on the Reference Composition approximation for Standard Seawater. We discuss uncertainties in both the Reference Composition and the Reference-Composition Salinity Scale on which Reference Salinity is reported. The Reference Composition provides a much-needed fixed benchmark but modified reference states will inevitably be required to improve the representation of Standard Seawater for some studies. The Reference-Composition Salinity Scale should remain unaltered to provide a stable representation of salinity for use with the TEOS-10 Gibbs function and in climate change detection studies. Second, when composition anomalies are present in seawater, no single salinity variable can fully represent the influence of dissolved material on the thermodynamic properties of seawater. We consider three distinct representations of salinity that have been used in previous studies and discuss the connections and distinctions between them. One of these variables provides the most accurate representation of density possible as well as improvements over Reference Salinity for the determination of other thermodynamic properties. It is referred to as "Density Salinity" and is represented by the symbol SAdens; it stands out as the most appropriate representation of salinity for use in dynamical physical oceanography. The other two salinity variables provide alternative measures of the mass fraction of dissolved material in seawater. "Solution Salinity", denoted SAsoln, is the most obvious extension of Reference Salinity to allow for composition anomalies; it provides a direct estimate of the mass fraction of dissolved material in solution. "Added-Mass Salinity", denoted SAadd, is motivated by a method used to report laboratory experiments; it represents the component of dissolved material added to Standard Seawater in terms of the mass of material before it enters solution. We also discuss a constructed conservative variable referred to as "Preformed Salinity", denoted S*, which will be useful in process-oriented numerical modelling studies. Finally, a conceptual framework for the incorporation of composition anomalies in numerical models is presented that builds from studies in which composition anomalies are simply ignored up to studies in which the influences of composition anomalies are accounted for using the results of biogeochemical models. 1TEOS-10: international thermodynamic equation of seawater 2010, http://www.teos-10.org.

  15. Update of the α - n Yields for Reactor Fuel Materials for the Interest of Nuclear Safeguards

    NASA Astrophysics Data System (ADS)

    Simakov, S. P.; van den Berg, Q. Y.

    2017-01-01

    The neutron yields caused by spontaneous α-decay of actinides and subsequent (α,xn) reactions were re-evaluated for the reactor fuel materials UO2, UF6, PuO2 and PuF4. For this purpose, the most recent reference data for decay parameters, α-particle stopping powers and (α,xn) cross sections were collected, analysed and used in calculations. The input data and elaborated code were validated against available thick target neutron yields in pure and compound materials measured at accelerators or with radioactive sources. This paper provides the specific neutron yields and their uncertainties resultant from α-decay of actinides 241Am, 249Bk, 252Cf, 242,244Cm, 237Np, 238-242Pu, 232Th and 232-236,238U in oxide and fluoride compounds. The obtained results are an update of previous reference tables issued by the Los Alamos National Laboratory in 1991 which were used for the safeguarding of radioactive materials by passive non-destructive techniques. The comparison of the updated values with previous ones shows an agreement within one estimated uncertainty (≈ 10%) for oxides, and deviations of up to 50% for fluorides.

  16. Realization of New and Enhanced Materials Properties Through Nanostructural Control

    DTIC Science & Technology

    2009-08-14

    repeated and verified by Paul Ashley at US Army RDECOM, Redstone Arsenal, ALand Warren Herman at the Laboratory for Physical Sciences (LPS), College...proposed in the following sections of this proposal. REFERENCES (AFOSR-FA9550-06-I-0042 relevant publications) I. Paul M. Wallace, Daniel R. B. Sluss...8. Fletcher Kimura, Gamal Khalil, Nobuyuki Zettsu, Younan Xi a, James B. Callis, Martin Goutennan, Larry R Dalton, Dana Dabin, and Miguel

  17. Global harmonization of food safety regulations: perspectives from Japan after the Fukushima nuclear accident.

    PubMed

    Yoshida, Mitsuru

    2014-08-01

    Japanese food self-sufficiency was only 39% on the basis of kcal in 2012, so Japan relies heavily on imported food. Hence the necessity of having international rules on the regulation of food contaminants is important especially for countries like Japan that depend on food imports. A One-Stop-Testing system is desired, in which the test result obtained from a single testing laboratory is accepted as valid worldwide. To establish this system, laboratory accreditation under international standards is a necessary step. Furthermore, the importance of supply of reference materials for internal quality control and proficiency testing for external quality control of each laboratory's analytical system is reviewed in connection with the experience of radioactive nuclide contamination resulting from the Fukushima nuclear power plant accident in March 2011. © 2013 Society of Chemical Industry.

  18. Responses to a questionnaire on networking between OIE Reference Laboratories and OIE Collaborating Centres.

    PubMed

    Brückner, G K; Linnane, S; Diaz, F; Vallat, B

    2007-01-01

    Two separate questionnaires were distributed to 20 OIE Collaborating Centres and 160 OIE Reference Laboratories to assess the current status of networking and collaboration among OIE Reference Laboratories and between OIE Reference Laboratories and OIE Collaborating Centres. The questionnaire for the OIE Reference Laboratories contained 7 sections with questions on networking between laboratories, reporting of information, biosecurity quality control, and financing. Emphasis was placed in obtaining information on inter-laboratory relationships and exchange of expertise, training needs and sharing of data and information. The questionnaire for the OIE Collaborating Centres contained six sections with the emphasis on aspects related to awareness of services that can be provided, expertise that could be made available, sharing of information and the relationship with the national veterinary services of the countries concerned. The responses to the questionnaires were collated, categorised and statistically evaluated to allow for tentative inferences on the data provided. Valuable information emanated from the data identifying the current status of networking and indicating possible shortcomings that could be addressed to improve networking.

  19. Recommendation for the review of biological reference intervals in medical laboratories.

    PubMed

    Henny, Joseph; Vassault, Anne; Boursier, Guilaine; Vukasovic, Ines; Mesko Brguljan, Pika; Lohmander, Maria; Ghita, Irina; Andreu, Francisco A Bernabeu; Kroupis, Christos; Sprongl, Ludek; Thelen, Marc H M; Vanstapel, Florent J L A; Vodnik, Tatjana; Huisman, Willem; Vaubourdolle, Michel

    2016-12-01

    This document is based on the original recommendation of the Expert Panel on the Theory of Reference Values of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC), updated guidelines were recently published under the auspices of the IFCC and the Clinical and Laboratory Standards Institute (CLSI). This document summarizes proposals for recommendations on: (i) The terminology, which is often confusing, noticeably concerning the terms of reference limits and decision limits. (ii) The method for the determination of reference limits according to the original procedure and the conditions, which should be used. (iii) A simple procedure allowing the medical laboratories to fulfill the requirements of the regulation and standards. The updated document proposes to verify that published reference limits are applicable to the laboratory involved. Finally, the strengths and limits of the revised recommendations (especially the selection of the reference population, the maintenance of the analytical quality, the choice of the statistical method used…) will be briefly discussed.

  20. Implementation of a National Reference Laboratory for Buruli Ulcer Disease in Togo

    PubMed Central

    Badziklou, Kossi; Halatoko, Wemboo Afiwa; Maman, Issaka; Vogel, Felix; Bidjada, Bawimodom; Awoussi, Koffi Somenou; Piten, Ebekalisai; Helfrich, Kerstin; Mengele, Carolin; Nitschke, Jörg; Amekuse, Komi; Wiedemann, Franz Xaver; Diefenhardt, Adolf; Kobara, Basile; Herbinger, Karl–Heinz; Kere, Abiba Banla; Prince-David, Mireille; Löscher, Thomas; Bretzel, Gisela

    2013-01-01

    Background In a previous study PCR analysis of clinical samples from suspected cases of Buruli ulcer disease (BUD) from Togo and external quality assurance (EQA) for local microscopy were conducted at an external reference laboratory in Germany. The relatively poor performance of local microscopy as well as effort and time associated with shipment of PCR samples necessitated the implementation of stringent EQA measures and availability of local laboratory capacity. This study describes the approach to implementation of a national BUD reference laboratory in Togo. Methodology Large scale outreach activities accompanied by regular training programs for health care professionals were conducted in the regions “Maritime” and “Central,” standard operating procedures defined all processes in participating laboratories (regional, national and external reference laboratories) as well as the interaction between laboratories and partners in the field. Microscopy was conducted at regional level and slides were subjected to EQA at national and external reference laboratories. For PCR analysis, sample pairs were collected and subjected to a dry-reagent-based IS2404-PCR (DRB-PCR) at national level and standard IS2404 PCR followed by IS2404 qPCR analysis of negative samples at the external reference laboratory. Principal Findings The inter-laboratory concordance rates for microscopy ranged from 89% to 94%; overall, microscopy confirmed 50% of all suspected BUD cases. The inter-laboratory concordance rate for PCR was 96% with an overall PCR case confirmation rate of 78%. Compared to a previous study, the rate of BUD patients with non-ulcerative lesions increased from 37% to 50%, the mean duration of disease before clinical diagnosis decreased significantly from 182.6 to 82.1 days among patients with ulcerative lesions, and the percentage of category III lesions decreased from 30.3% to 19.2%. Conclusions High inter-laboratory concordance rates as well as case confirmation rates of 50% (microscopy), 71% (PCR at national level), and 78% (including qPCR confirmation at external reference laboratory) suggest high standards of BUD diagnostics. The increase of non-ulcerative lesions, as well as the decrease in diagnostic delay and category III lesions, prove the effect of comprehensive EQA and training measures involving also procedures outside the laboratory. PMID:23359828

  1. Implementation of a national reference laboratory for Buruli ulcer disease in Togo.

    PubMed

    Beissner, Marcus; Huber, Kristina Lydia; Badziklou, Kossi; Halatoko, Wemboo Afiwa; Maman, Issaka; Vogel, Felix; Bidjada, Bawimodom; Awoussi, Koffi Somenou; Piten, Ebekalisai; Helfrich, Kerstin; Mengele, Carolin; Nitschke, Jörg; Amekuse, Komi; Wiedemann, Franz Xaver; Diefenhardt, Adolf; Kobara, Basile; Herbinger, Karl-Heinz; Kere, Abiba Banla; Prince-David, Mireille; Löscher, Thomas; Bretzel, Gisela

    2013-01-01

    In a previous study PCR analysis of clinical samples from suspected cases of Buruli ulcer disease (BUD) from Togo and external quality assurance (EQA) for local microscopy were conducted at an external reference laboratory in Germany. The relatively poor performance of local microscopy as well as effort and time associated with shipment of PCR samples necessitated the implementation of stringent EQA measures and availability of local laboratory capacity. This study describes the approach to implementation of a national BUD reference laboratory in Togo. Large scale outreach activities accompanied by regular training programs for health care professionals were conducted in the regions "Maritime" and "Central," standard operating procedures defined all processes in participating laboratories (regional, national and external reference laboratories) as well as the interaction between laboratories and partners in the field. Microscopy was conducted at regional level and slides were subjected to EQA at national and external reference laboratories. For PCR analysis, sample pairs were collected and subjected to a dry-reagent-based IS2404-PCR (DRB-PCR) at national level and standard IS2404 PCR followed by IS2404 qPCR analysis of negative samples at the external reference laboratory. The inter-laboratory concordance rates for microscopy ranged from 89% to 94%; overall, microscopy confirmed 50% of all suspected BUD cases. The inter-laboratory concordance rate for PCR was 96% with an overall PCR case confirmation rate of 78%. Compared to a previous study, the rate of BUD patients with non-ulcerative lesions increased from 37% to 50%, the mean duration of disease before clinical diagnosis decreased significantly from 182.6 to 82.1 days among patients with ulcerative lesions, and the percentage of category III lesions decreased from 30.3% to 19.2%. High inter-laboratory concordance rates as well as case confirmation rates of 50% (microscopy), 71% (PCR at national level), and 78% (including qPCR confirmation at external reference laboratory) suggest high standards of BUD diagnostics. The increase of non-ulcerative lesions, as well as the decrease in diagnostic delay and category III lesions, prove the effect of comprehensive EQA and training measures involving also procedures outside the laboratory.

  2. Detecting Nanophase Weathering Products with CheMin: Reference Intensity Ratios of Allophane, Aluminosilicate Gel, and Ferrihydrite

    NASA Technical Reports Server (NTRS)

    Rampe, E. B.; Bish, D. L.; Chipera, S. J.; Morris, R. V.; Achilles, C. N.; Ming, D W.; Blake, D. F.; Anderson, R. C.; Bristow, T. F.; Crisp, A.; hide

    2013-01-01

    X-ray diffraction (XRD) data collected of the Rocknest samples by the CheMin instrument on Mars Science Laboratory suggest the presence of poorly crystalline or amorphous materials [1], such as nanophase weathering products or volcanic and impact glasses. The identification of the type(s) of X-ray amorphous material at Rocknest is important because it can elucidate past aqueous weathering processes. The presence of volcanic and impact glasses would indicate that little chemical weathering has occurred because glass is highly susceptible to aqueous alteration. The presence of nanophase weathering products, such as allophane, nanophase iron-oxides, and/or palagonite, would indicate incipient chemical weathering. Furthermore, the types of weathering products present could help constrain pH conditions and identify which primary phases altered to form the weathering products. Quantitative analysis of phases from CheMin data is achieved through Reference Intensity Ratios (RIRs) and Rietveld refinement. The RIR of a mineral (or mineraloid) that relates the scattering power of that mineral (typically the most intense diffraction line) to the scattering power of a separate mineral standard such as corundum [2]. RIRs can be calculated from XRD patterns measured in the laboratory by mixing a mineral with a standard in known abundances and comparing diffraction line intensities of the mineral to the standard. X-ray amorphous phases (e.g., nanophase weathering products) have broad scattering signatures rather than sharp diffraction lines. Thus, RIRs of X-ray amorphous materials are calculated by comparing the area under one of these broad scattering signals with the area under a diffraction line in the standard. Here, we measured XRD patterns of nanophase weathering products (allophane, aluminosilicate gel, and ferrihydrite) mixed with a mineral standard (beryl) in the CheMinIV laboratory instrument and calculated their RIRs to help constrain the abundances of these phases in the Rocknest samples.

  3. Make versus buy: a financial perspective.

    PubMed

    Kisner, Harold J

    2003-01-01

    Clinical laboratories are often faced with the decision to either perform a service in-house using their own assets or outsource the service to another vendor. This decision affects many aspects of the laboratory's business, from the macroeconomic perspective of outsourcing the laboratory service to a laboratory vendor, to the microeconomics of determining whether to refer a test out to their reference laboratory or perform the test in-house. The basis for decision making includes many variables, but a detailed financial analysis is usually the basis for the decision, especially when the decision only affects the laboratory and not the rest of the institution. Other factors often come into play, and depending on the magnitude, the "make versus buy" decision could be based more on strategic or political factors than economics. Even when noneconomic factors are involved, an effort usually is made to quantify those factors so that the make versus buy decision is reduced to financial terms. The previous article in this issue, "Effectively Managing Your Reference Laboratory Relationship" by Ronald L. Weiss, M.D., focused on the "buy" decision relating to managing the reference laboratory relationship. Although that article took a more clinical perspective through the eyes of the reference laboratory, this article looks at the make versus buy decision from a financial perspective through the eyes of the buying party.

  4. Achievements and Future Directions of the APFCB Mass Spectrometry Harmonisation Project on Serum Testosterone.

    PubMed

    Greaves, Ronda F; Ho, Chung S; Hoad, Kirsten E; Joseph, John; McWhinney, Brett; Gill, Janice P; Koal, Therese; Fouracre, Chris; Iu, Heidi P; Cooke, Brian R; Boyder, Conchita; Pham, Hai T; Jolly, Lisa M

    2016-05-01

    As an outcome of the 2010 Asian Pacific Conference for Chromatography and Mass Spectrometry in Hong Kong, a collaborative working group was formed to promote the harmonisation of mass spectrometry methods. The Mass Spectrometry Harmonisation Working Group resides under the combined auspices of the Asia-Pacific Federation for Clinical Biochemistry and Laboratory Medicine (APFCB) and the Australasian Association of Clinical Biochemists (AACB). A decision was made to initially focus attention on serum steroids due to the common interest of members in this area; with the first steroid to assess being testosterone. In principle, full standardisation with traceability should be achievable for all steroids as they are small compounds with defined molecular weight and structure. In order to achieve this we need certified reference materials, reference methods, reference laboratories, reference intervals and external quality assurance programs; each being an important pillar in the process. When all the pillars are present, such as for serum testosterone, it is feasible to fully standardise the liquid chromatography - tandem mass spectrometry (LC-MS/MS) methods. In a collaborative process with interested stakeholders, we commenced on a pathway to provide ongoing assessment and seek opportunities for improvement in the LC-MS/MS methods for serum steroids. Here we discuss the outcomes to date and major challenges related to the accurate measurement of serum steroids with a focus on serum testosterone.

  5. Uptake of recommended common reference intervals for chemical pathology in Australia.

    PubMed

    Jones, Graham Rd; Koetsier, Sabrina

    2017-05-01

    Background Reference intervals are a vital part of reporting numerical pathology results. It is known, however, that variation in reference intervals between laboratories is common, even when analytical methods support common reference intervals. In response to this, in Australia, the Australasian Association of Clinical Biochemists together with the Royal College of Pathologists of Australasia published in 2014 a set of recommended common reference intervals for 11 common serum analytes (sodium, potassium, chloride, bicarbonate, creatinine male, creatinine female, calcium, calcium adjusted for albumin, phosphate, magnesium, lactate dehydrogenase, alkaline phosphatase and total protein). Methods Uptake of recommended common reference intervals in Australian laboratories was assessed using data from four annual cycles of the RCPAQAP reference intervals external quality assurance programme. Results Over three years, from 2013 to 2016, the use of the recommended upper and lower reference limits has increased from 40% to 83%. Nearly half of the intervals in use by enrolled laboratories in 2016 have been changed in this time period, indicating an active response to the guidelines. Conclusions These data support the activities of the Australasian Association of Clinical Biochemists and Royal College of Pathologists of Australasia in demonstrating a change in laboratory behaviour to reduce unnecessary variation in reference intervals and thus provide a consistent message to doctor and patients irrespective of the laboratory used.

  6. New Carbonate Standard Reference Materials for Boron Isotope Geochemistry

    NASA Astrophysics Data System (ADS)

    Stewart, J.; Christopher, S. J.; Day, R. D.

    2015-12-01

    The isotopic composition of boron (δ11B) in marine carbonates is well established as a proxy for past ocean pH. Yet, before palaeoceanographic interpretation can be made, rigorous assessment of analytical uncertainty of δ11B data is required; particularly in light of recent interlaboratory comparison studies that reported significant measurement disagreement between laboratories [1]. Well characterised boron standard reference materials (SRMs) in a carbonate matrix are needed to assess the accuracy and precision of carbonate δ11B measurements throughout the entire procedural chemistry; from sample cleaning, to ionic separation of boron from the carbonate matrix, and final δ11B measurement by multi-collector inductively coupled plasma mass spectrometry. To date only two carbonate reference materials exist that have been value-assigned by the boron isotope measurement community [2]; JCp-1 (porites coral) and JCt-1 (Giant Clam) [3]. The National Institute of Standards and Technology (NIST) will supplement these existing standards with new solution based inorganic carbonate boron SRMs that replicate typical foraminiferal and coral B/Ca ratios and δ11B values. These new SRMs will not only ensure quality control of full procedural chemistry between laboratories, but have the added benefits of being both in abundant supply and free from any restrictions associated with shipment of biogenic samples derived from protected species. Here we present in-house δ11B measurements of these new boron carbonate SRM solutions. These preliminary data will feed into an interlaboratory comparison study to establish certified values for these new NIST SRMs. 1. Foster, G.L., et al., Chemical Geology, 2013. 358(0): p. 1-14. 2. Gutjahr, M., et al., Boron Isotope Intercomparison Project (BIIP): Development of a new carbonate standard for stable isotopic analyses. Geophysical Research Abstracts, EGU General Assembly 2014, 2014. 16(EGU2014-5028-1). 3. Inoue, M., et al., Geostandards and Geoanalytical Research, 2004. 28(3): p. 411-416.

  7. Laboratory Reference Spectroscopy of Icy Satellite Candidate Surface Materials (Invited)

    NASA Astrophysics Data System (ADS)

    Dalton, J. B.; Jamieson, C. S.; Shirley, J. H.; Pitman, K. M.; Kariya, M.; Crandall, P.

    2013-12-01

    The bulk of our knowledge of icy satellite composition continues to be derived from ultraviolet, visible and infrared remote sensing observations. Interpretation of remote sensing observations relies on availability of laboratory reference spectra of candidate surface materials. These are compared directly to observations, or incorporated into models to generate synthetic spectra representing mixtures of the candidate materials. Spectral measurements for the study of icy satellites must be taken under appropriate conditions (cf. Dalton, 2010; also http://mos.seti.org/icyworldspectra.html for a database of compounds) of temperature (typically 50 to 150 K), pressure (from 10-9 to 10-3 Torr), viewing geometry, (i.e., reflectance), and optical depth (must manifest near infrared bands but avoid saturation in the mid-infrared fundamentals). The Planetary Ice Characterization Laboratory (PICL) is being developed at JPL to provide robust reference spectra for icy satellite surface materials. These include sulfate hydrates, hydrated and hydroxylated minerals, and both organic and inorganic volatile ices. Spectral measurements are performed using an Analytical Spectral Devices FR3 portable grating spectrometer from .35 to 2.5 microns, and a Thermo-Nicolet 6500 Fourier-Transform InfraRed (FTIR) spectrometer from 1.25 to 20 microns. These are interfaced with the Basic Extraterrestrial Environment Simulation Testbed (BEEST), a vacuum chamber capable of pressures below 10-9 Torr with a closed loop liquid helium cryostat with custom heating element capable of temperatures from 30-800 Kelvins. To generate optical constants (real and imaginary index of refraction) for use in nonlinear mixing models (i.e., Hapke, 1981 and Shkuratov, 1999), samples are ground and sieved to six different size fractions or deposited at varying rates to provide a range of grain sizes for optical constants calculations based on subtractive Kramers-Kronig combined with Hapke forward modeling (Dalton and Pitman, 2012). We will report on recent results, including spectra of sulfate hydrates, simple organic molecules, and volatile ices measured at PICL in support of past, present and planned missions. We gratefully acknowledge the support of JPL's Research and Technology Development and Strategic Hire Programs, and of the NASA Outer Planets Research and Planetary Geology and Geophysics programs. Dalton, III, J.B., Spectroscopy of icy moon surface materials, Space Sci. Rev. 153:219-247, 2010. Dalton, III, J.B., and Pitman, K.M., Low temperature optical constants of some hydrated sulfates relevant to planetary surfaces, J. Geophys. Res. 117:E09001, doi:10.1029/2011JE004036, 2012. Hapke, B.W., Bidirectional reflectance spectroscopy I. Theory, J. Geophys. Res. 86, 3039-3054, 1981. Shkuratov, Y., L. Starukhina, H. Hoffmann, and G. Arnold, A model of spectral albedo of particulate surfaces: Implications for optical properties of the Moon, Icarus 137, 235-246, 1999.

  8. Generation and Characterization of Six Recombinant Botulinum Neurotoxins as Reference Material to Serve in an International Proficiency Test

    PubMed Central

    Weisemann, Jasmin; Krez, Nadja; Fiebig, Uwe; Worbs, Sylvia; Skiba, Martin; Endermann, Tanja; Dorner, Martin B.; Bergström, Tomas; Muñoz, Amalia; Zegers, Ingrid; Müller, Christian; Jenkinson, Stephen P.; Avondet, Marc-Andre; Delbrassinne, Laurence; Denayer, Sarah; Zeleny, Reinhard; Schimmel, Heinz; Åstot, Crister; Dorner, Brigitte G.; Rummel, Andreas

    2015-01-01

    The detection and identification of botulinum neurotoxins (BoNT) is complex due to the existence of seven serotypes, derived mosaic toxins and more than 40 subtypes. Expert laboratories currently use different technical approaches to detect, identify and quantify BoNT, but due to the lack of (certified) reference materials, analytical results can hardly be compared. In this study, the six BoNT/A1–F1 prototypes were successfully produced by recombinant techniques, facilitating handling, as well as improving purity, yield, reproducibility and biosafety. All six BoNTs were quantitatively nicked into active di-chain toxins linked by a disulfide bridge. The materials were thoroughly characterized with respect to purity, identity, protein concentration, catalytic and biological activities. For BoNT/A1, B1 and E1, serotypes pathogenic to humans, the catalytic activity and the precise protein concentration were determined by Endopep-mass spectrometry and validated amino acid analysis, respectively. In addition, BoNT/A1, B1, E1 and F1 were successfully detected by immunological assays, unambiguously identified by mass spectrometric-based methods, and their specific activities were assigned by the mouse LD50 bioassay. The potencies of all six BoNT/A1–F1 were quantified by the ex vivo mouse phrenic nerve hemidiaphragm assay, allowing a direct comparison. In conclusion, highly pure recombinant BoNT reference materials were produced, thoroughly characterized and employed as spiking material in a worldwide BoNT proficiency test organized by the EQuATox consortium. PMID:26703728

  9. Association of Reference Pricing for Diagnostic Laboratory Testing With Changes in Patient Choices, Prices, and Total Spending for Diagnostic Tests.

    PubMed

    Robinson, James C; Whaley, Christopher; Brown, Timothy T

    2016-09-01

    Prices for laboratory and other clinical services vary widely. Employers and insurers increasingly are adopting "reference pricing" policies to create incentives for patients to select lower-priced facilities. To measure the association between implementation of reference pricing and patient choice of laboratory, test prices, patient out-of-pocket spending, and insurer spending. We conducted an observational study of changes in laboratory pricing and selection by employees of a large national grocery firm (n = 30 415) before and after the firm implemented a reference pricing policy for laboratory services and compared the findings with changes over the same period for policy holders of a large national insurer that did not implement reference pricing (n = 181 831). The grocery firm established a maximum payment limit at the 60th percentile of the distribution of prices for each laboratory test in each region. Employees were provided with data on prices at all laboratories through a mobile digital platform. Patients selecting a laboratory that charged more than the payment limit were required to pay the full difference themselves. A total of 2.13 million claims were analyzed for 285 types of in vitro diagnostic tests between 2010 and 2013. Patient choice of laboratory, price paid per test, patient out-of-pocket costs, and employer spending. Compared with trends in prices paid by insurance policy holders not subject to reference pricing, and after adjusting for characteristics of tests and patients, implementation of reference pricing was associated with a 31.9% reduction (95% CI, 20.6%-41.6%) in average price paid per test by the third year of the program. In these 3 years, total spending on laboratory tests declined by $2.57 million (95% CI, $1.59-$3.35 million). Out-of-pocket costs by patients declined by $1.05 million (95% CI, $0.73-$1.37 million). Spending by the employer declined by $1.70 million (95% CI, $0.92-$2.48 million). When combined with access to price information, reference pricing was associated with patient choice of lower-cost laboratories and reductions in prices and payments by both employer and employees.

  10. The assessment of ultrasonic tests as a tool for qualification and diagnostic study of traditional highly porous and soft stone materials used in the built heritage of the past.

    NASA Astrophysics Data System (ADS)

    Calia, A.; Sileo, M.; Leucci, G.

    2012-04-01

    Ultrasonic tests are performing tools for the quality assessment and selection of stone as building materials, as well as for the detection of faults within architectural and structural elements. The use of the non destructive and non invasive diagnostic techniques has always advantages in the activities on pre-existing buildings, in terms of sustainability; moreover, it is a need with respect to the conservation constraints when we act on the historical-architectural heritage. Ultrasonic technique is widely and successfully performed in the diagnosis and control of the restoration works on concrete and compact stone artefacts. Specific problems arise from its use with reference to highly porous and soft stones, in particular bi-component materials with grains-cement binder structure, such as calcarenites. Low ultrasonic propagation velocity, typically associated to the soft and porous materials can be easily affected by disturbing factors, in primis water (in vapour or liquid state), that can easily and frequently penetrates inside them and in significant amounts, due to their high open porosity. The analysis and interpretation of the data acquired by in situ investigations have to take into account this additional contribution. In the same way, on site structures and materials can be easily interested by salt presence and deposition within the pores, that can furtherly interfere on the data significance, as well as it is important to know the variability of data due to the different state of conservation of the stones. The influence of all these factors on the response to the ultrasonic tests needs to be investigated by laboratory controlled conditions, preliminarily to the in situ application. The present work refers to the experimental activity devoted to investigate the critical aspects that have been mentioned above and the results obtained. It is a part of a larger activity with the final aim to set up non invasive diagnostic procedures for the analysis and qualification of ancient masonries, realised with traditional soft stones, used as building materials in the Southern Italy. This activity is carried out within the AITECH network (Applied Innovation Technologies for Diagnosis and Conservation of Built Heritage), a regional research laboratory infrastructure (Apulian region, Southern Italy) funded within the FSE and FESR programs and realised by the contribution of the Italian CNR and Salento University. In particular, ultrasonic velocity propagation have been measured on different petrographic kinds of calcarenitic materials. The influence of the sample size -the scale effect- has also been investigated. Velocity data have been recorded on the samples in the following conditions: a) dry, wet and different rates of the humidity content b) salt saturation c) after ageing by salt crystallisation cycles. Finally, ultrasonic tests have been performed on some samples treated by inorganic silica consolidant. This experimental laboratory investigation is the preliminary activity to assess the performance potential of the ultrasonic tests as effective tool for the qualification and diagnosis before and after treatments, with reference to the specific critical aspects related to highly porous and soft stone materials, traditionally used in the built heritage of the past.

  11. Microbial specificity of metallic surfaces exposed to ambient seawater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zaidi, B.R.; Bard, R.F.; Tosteson, T.R.

    1984-09-01

    High-molecular-weight materials associated with the extracellular matrix and film found on titanium and aluminum surfaces after exposure to flowing coastal seawater were isolated. This material was purified by hydroxylapatite chromatography and subsequently employed to produce antibodies in the toad, Bufo marinus. The antibodies were immobilized on a solid support and employed to isolate adhesion-enhancing, high-molecular-weight materials from the laboratory culture media of bacterial strains recovered from the respective metallic surfaces during the course of their exposure to seawater. The adhesion-enhancing materials produced by the surface-associated bacterial strains were immunologically related to the extracellular biofouling matrix material found on the surfacesmore » from which these bacteria were isolated. The surface selectivity of these bacterial strains appeared to be based on the specificity of the interaction between adhesion-enhancing macromolecules produced by these bacteria and the surfaces in question. 30 references, 6 tables.« less

  12. Certification of NIST standard reference material 2389a, amino acids in 0.1 mol/L HCl--quantification by ID LC-MS/MS.

    PubMed

    Lowenthal, Mark S; Yen, James; Bunk, David M; Phinney, Karen W

    2010-05-01

    An isotope-dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS) measurement procedure was developed to accurately quantify amino acid concentrations in National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 2389a-amino acids in 0.1 mol/L hydrochloric acid. Seventeen amino acids were quantified using selected reaction monitoring on a triple quadrupole mass spectrometer. LC-MS/MS results were compared to gravimetric measurements from the preparation of SRM 2389a-a reference material developed at NIST and intended for use in intra-laboratory calibrations and quality control. Quantitative mass spectrometry results and gravimetric values were statistically combined into NIST-certified mass fraction values with associated uncertainty estimates. Coefficients of variation (CV) for the repeatability of the LC-MS/MS measurements among amino acids ranged from 0.33% to 2.7% with an average CV of 1.2%. Average relative expanded uncertainty of the certified values including Types A and B uncertainties was 3.5%. Mean accuracy of the LC-MS/MS measurements with gravimetric preparation values agreed to within |1.1|% for all amino acids. NIST SRM 2389a will be available for characterization of routine methods for amino acid analysis and serves as a standard for higher-order measurement traceability. This is the first time an ID LC-MS/MS methodology has been applied for quantifying amino acids in a NIST SRM material.

  13. Quantitative Analysis of Plutonium Content in Particles Collected from a Certified Reference Material by Total Nuclear Reaction Energy (Q Value) Spectroscopy

    NASA Astrophysics Data System (ADS)

    Croce, M. P.; Hoover, A. S.; Rabin, M. W.; Bond, E. M.; Wolfsberg, L. E.; Schmidt, D. R.; Ullom, J. N.

    2016-08-01

    Microcalorimeters with embedded radioisotopes are an emerging category of sensor with advantages over existing methods for isotopic analysis of trace-level nuclear materials. For each nuclear decay, the energy of all decay products captured by the absorber (alpha particles, gamma rays, X-rays, electrons, daughter nuclei, etc.) is measured in one pulse. For alpha-decaying isotopes, this gives a measurement of the total nuclear reaction energy (Q value) and the spectra consist of well-separated, narrow peaks. We have demonstrated a simple mechanical alloying process to create an absorber structure consisting of a gold matrix with small inclusions of a radioactive sample. This absorber structure provides an optimized energy thermalization environment, resulting in high-resolution spectra with minimal tailing. We have applied this process to the analysis of particles collected from the surface of a plutonium metal certified reference material (CRM-126A from New Brunswick Laboratory) and demonstrated isotopic analysis by microcalorimeter Q value spectroscopy. Energy resolution from the Gaussian component of a Bortels function fit was 1.3 keV FWHM at 5244 keV. The collected particles were integrated directly into the detector absorber without any chemical processing. The ^{238}Pu/^{239}Pu and ^{240}Pu/^{239}Pu mass ratios were measured and the results confirmed against the certificate of analysis for the reference material. We also demonstrated inter-element analysis capability by measuring the ^{241}Am/^{239}Pu mass ratio.

  14. Calibration of BCR-ABL1 mRNA quantification methods using genetic reference materials is a valid strategy to report results on the international scale.

    PubMed

    Mauté, Carole; Nibourel, Olivier; Réa, Delphine; Coiteux, Valérie; Grardel, Nathalie; Preudhomme, Claude; Cayuela, Jean-Michel

    2014-09-01

    Until recently, diagnostic laboratories that wanted to report on the international scale had limited options: they had to align their BCR-ABL1 quantification methods through a sample exchange with a reference laboratory to derive a conversion factor. However, commercial methods calibrated on the World Health Organization genetic reference panel are now available. We report results from a study designed to assess the comparability of the two alignment strategies. Sixty follow-up samples from chronic myeloid leukemia patients were included. Two commercial methods calibrated on the genetic reference panel were compared to two conversion factor methods routinely used at Saint-Louis Hospital, Paris, and at Lille University Hospital. Results were matched against concordance criteria (i.e., obtaining at least two of the three following landmarks: 50, 75 and 90% of the patient samples within a 2-fold, 3-fold and 5-fold range, respectively). Out of the 60 samples, more than 32 were available for comparison. Compared to the conversion factor method, the two commercial methods were within a 2-fold, 3-fold and 5-fold range for 53 and 59%, 89 and 88%, 100 and 97%, respectively of the samples analyzed at Saint-Louis. At Lille, results were 45 and 85%, 76 and 97%, 100 and 100%, respectively. Agreements between methods were observed in the four comparisons performed. Our data show that the two commercial methods selected are concordant with the conversion factor methods. This study brings the proof of principle that alignment on the international scale using the genetic reference panel is compatible with the patient sample exchange procedure. We believe that these results are particularly important for diagnostic laboratories wishing to adopt commercial methods. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  15. On the critical or geometrical nature of the observed scaling laws associated with the fracture and faulting processes

    NASA Astrophysics Data System (ADS)

    Potirakis, Stelios M.; Kopanas, John; Antonopoulos, George; Nomicos, Constantinos; Eftaxias, Konstantinos

    2015-04-01

    One of the largest controversial issues of the materials science community is the interpretation of scaling laws associated with the fracture and faulting processes. Especially, an important open question is whether the spatial and temporal complexity of earthquakes and fault structures, above all the interpretation of the observed scaling laws, emerge from geometrical and material built-in heterogeneities or from the critical behavior inherent to the nonlinear equations governing the earthquake dynamics. Crack propagation is the basic mechanism of material's failure. A number of laboratory studies carried out on a wide range of materials have revealed the existence of EMEs during fracture experiments, while these emissions are ranging in a wide frequency spectrum, i.e., from the kHz to the MHz bands. A crucial feature observed on the laboratory scale is that the MHz EME systematically precedes the corresponding kHz one. The aforementioned crucial feature is observed in geophysical scale, as well. The remarkable asynchronous appearance of these two EMEs both on the laboratory and the geophysical scale implies that they refer to different final stages of faulting process. Accumulated laboratory, theoretical and numerical evidence supports the hypothesis that the MHz EME is emitted during the fracture of process of heterogeneous medium surrounding the family of strong entities (asperities) distributed along the fault sustaining the system. The kHz EME is attributed to the family of asperities themselves. We argue in terms of the fracture induced pre-seismic MHz-kHz EMEs that the scaling laws associated with the fracture of heterogeneous materials emerge from the critical behavior inherent to the nonlinear equations governing their dynamics (second-order phase transition), while the scaling laws associated with the fracture of family of asperities have geometric nature, namely, are rooted in the fractal nature of the population of asperities.

  16. Dissolution of Material and Test reactor Fuel in an H-Canyon Dissolver

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daniel, W. E.; Rudisill, T. S.; O'Rourke, P. E.

    2017-01-26

    In an amended record of decision for the management of spent nuclear fuel (SNF) at the Savannah River Site, the US Department of Energy has authorized the dissolution and recovery of U from 1000 bundles of Al-clad SNF. The SNF is fuel from domestic and foreign research reactors and is typically referred to as Material Test Reactor (MTR) fuel. Bundles of MTR fuel containing assemblies fabricated from U-Al alloys (or other U compounds) are currently dissolved using a Hg-catalyzed HNO3 flowsheet. Since the development of the existing flowsheet, improved experimental methods have been developed to more accurately characterize the offgasmore » composition and generation rate during laboratory dissolutions. Recently, these new techniques were successfully used to develop a flowsheet for the dissolution of High Flux Isotope Reactor (HFIR) fuel. Using the data from the HFIR dissolution flowsheet development and necessary laboratory experiments, the Savannah River National Laboratory (SRNL) was requested to define flowsheet conditions for the dissolution of MTR fuels. With improved offgas characterization techniques, SRNL will be able define the number of bundles of fuel which can be charged to an H-Canyon dissolver with much less conservatism.« less

  17. Cell Line Controls for the Genotyping of a Spectrum of Human Single Nucleotide Polymorphisms in the Clinical Laboratory.

    PubMed

    Kimbacher, Christine; Paar, Christian; Freystetter, Andrea; Berg, Joerg

    2018-05-01

    Genotyping for clinically important single nucleotide polymorphisms (SNPs) is performed by many clinical routine laboratories. To support testing, quality controls and reference materials are needed. Those may be derived from residual patient samples, left over samples of external quality assurance schemes, plasmid DNA or DNA from cell lines. DNAs from cell lines are commutable and available in large amounts. DNA from 38 cell lines were examined for suitability as controls in 11 SNP assays that are frequently used in a clinical routine laboratory: FV (1691G>A), FII (20210G>A), PAI-1 4G/5G polymorphism, MTHFR (677C>T, 1298A>C), HFE (H63D, S65C, C282Y), APOE (E2, E3, E4), LPH (-13910C>T), UGT1A1 (*28, *36, *37), TPMT (*2, *3A, *3B, *3C), VKORC1 (-1639G>A, 1173C>T), CYP2C9 (*2, *3, *5). Genotyping was performed by real-time PCR with melting curve analysis and confirmed by bi-directional sequencing. We find an almost complete spectrum of genotypic constellations within these 38 cell lines. About 12 cell lines appear sufficient as genotypic controls for the 11 SNP assays by covering almost all of the genotypes. However, hetero- and homozygous genotypes for FII and the alleles TPMT*2, UGT1A1*37 and CYP2C9*5 were not detected in any of the cell lines. DNA from most of the examined cell lines appear suitable as quality controls for these SNP assays in the laboratory routine, as to the implementation of those assays or to prepare samples for quality assurance schemes. Our study may serve as a pilot to further characterize these cell lines to arrive at the status of reference materials.

  18. Technical evaluation report of the Specialists Meeting on Characterization of Low Cycle High Temperature Fatigue by the Strainrange Partitioning Method

    NASA Technical Reports Server (NTRS)

    Drapier, J. M.; Hirschberg, M. H.

    1979-01-01

    The ability of the Strainrange Partitioning Method SRP was evaluated to correlate the creep-fatigue behavior of gas turbine materials and to predict the creep fatigue life of laboratory specimens subjected to complex cycling conditions. A reference body of high temperature creep fatigue data which can be used in the evaluation of other SRP and low cycle high temperature fatigue predictive techniques was provided.

  19. The impact of preclinical irreproducibility on drug development.

    PubMed

    Freedman, L P; Gibson, M C

    2015-01-01

    The development of novel therapeutics depends and builds upon the validity and reproducibility of previously published data and findings. Yet irreproducibility is pervasive in preclinical life science research and can be traced to cumulative errors or flaws in several areas, including reference materials, study design, laboratory protocols, and data collection and analysis. The expanded development and use of consensus-based standards and well-documented best practices is needed to both enhance reproducibility and drive therapeutic innovations. © 2014 ASCPT.

  20. ANSI-ASQ National Accreditation Board /ACLASS

    DTIC Science & Technology

    2011-03-28

    unclassified c. THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18  Laboratories – ISO / IEC 17025  Inspection...Bodies – ISO / IEC 17020  RMPs – ISO Guide 34 (Reference Materials)  PT Providers – ISO 17043  Product Certifiers – ISO Guide 65  Government...Programs: DoD ELAP, EPA Energy Star, CPSC Toy Safety, NRC, NIST IPV6, NLLAP, NEFAP  TRAINING Programs  Certification Bodies – ISO / IEC 17021

  1. Repair, Evaluation, Maintenance, and Rehabilitation Research Program: Factors Related to the Performance of Concrete Repair Materials.

    DTIC Science & Technology

    1988-03-01

    in reference HRS 78.) The ASTM C 883 effective shrinkage standard test method involves constructing a laminate consisting of an epoxy-resin system...Evaluation of a Hiah-Strenrth Polyester Snythetic Concrete, U.S. Army Construction Engineering Research Laboratory, CERL Technical Report M-2, Champaign...Colorado, August 1, 1983. Can 67 F. Canovas, (Effects of ) Temperature Ch anges on Epoxy Pavements, Informes de la construccion (Madrid), 19, No. 189, pp

  2. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 °C. Part 9: reference procedure for the measurement of catalytic concentration of alkaline phosphatase International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Scientific Division, Committee on Reference Systems of Enzymes (C-RSE) (1)).

    PubMed

    Schumann, Gerhard; Klauke, Rainer; Canalias, Francesca; Bossert-Reuther, Steffen; Franck, Paul F H; Gella, F-Javier; Jørgensen, Poul J; Kang, Dongchon; Lessinger, Jean-Marc; Panteghini, Mauro; Ceriotti, Ferruccio

    2011-09-01

    Abstract This paper is the ninth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 °C and the certification of reference preparations. Other parts deal with: Part 1. The concept of reference procedures for the measurement of catalytic activity concentrations of enzymes; Part 2. Reference procedure for the measurement of catalytic concentration of creatine kinase; Part 3. Reference procedure for the measurement of catalytic concentration of lactate dehydrogenase; Part 4. Reference procedure for the measurement of catalytic concentration of alanine aminotransferase; Part 5. Reference procedure for the measurement of catalytic concentration of aspartate aminotransferase; Part 6. Reference procedure for the measurement of catalytic concentration of γ-glutamyltransferase; Part 7. Certification of four reference materials for the determination of enzymatic activity of γ-glutamyltransferase, lactate dehydrogenase, alanine aminotransferase and creatine kinase at 37 °C; Part 8. Reference procedure for the measurement of catalytic concentration of α-amylase. The procedure described here is derived from the previously described 30 °C IFCC reference method. Differences are tabulated and commented on in Appendix 1.

  3. Determination of total cadmium, lead, arsenic, mercury and inorganic arsenic in mushrooms: outcome of IMEP-116 and IMEP-39

    PubMed Central

    Cordeiro, F.; Llorente-Mirandes, T.; López-Sánchez, J.F.; Rubio, R.; Sánchez Agullo, A.; Raber, G.; Scharf, H.; Vélez, D.; Devesa, V.; Fiamegos, Y.; Emteborg, H.; Seghers, J.; Robouch, P.; de la Calle, M.B.

    2015-01-01

    The Institute for Reference Materials and Measurements (IRMM) of the Joint Research Centre (JRC), a Directorate General of the European Commission, operates the International Measurement Evaluation Program (IMEP). IMEP organises inter-laboratory comparisons in support of European Union policies. This paper presents the results of two proficiency tests (PTs): IMEP-116 and IMEP-39, organised for the determination of total Cd, Pb, As, Hg and inorganic As (iAs) in mushrooms. Participation in IMEP-116 was restricted to National Reference Laboratories (NRLs) officially appointed by national authorities in European Union member states. IMEP-39 was open to all other laboratories wishing to participate. Thirty-seven participants from 25 countries reported results in IMEP-116, and 62 laboratories from 36 countries reported for the IMEP-39 study. Both PTs were organised in support to Regulation (EC) No. 1881/2006, which sets the maximum levels for certain contaminants in food. The test item used in both PTs was a blend of mushrooms of the variety shiitake (Lentinula edodes). Five laboratories, with demonstrated measurement capability in the field, provided results to establish the assigned values (X ref). The standard uncertainties associated to the assigned values (u ref) were calculated by combining the uncertainty of the characterisation (u char) with a contribution for homogeneity (u bb) and for stability (u st), whilst u char was calculated following ISO 13528. Laboratory results were rated with z- and zeta (ζ)-scores in accordance with ISO 13528. The standard deviation for proficiency assessment, σ p, ranged from 10% to 20% depending on the analyte. The percentage of satisfactory z-scores ranged from 81% (iAs) to 97% (total Cd) in IMEP-116 and from 64% (iAs) to 84% (total Hg) in IMEP-39. PMID:25365736

  4. Determination of total cadmium, lead, arsenic, mercury and inorganic arsenic in mushrooms: outcome of IMEP-116 and IMEP-39.

    PubMed

    Cordeiro, F; Llorente-Mirandes, T; López-Sánchez, J F; Rubio, R; Sánchez Agullo, A; Raber, G; Scharf, H; Vélez, D; Devesa, V; Fiamegos, Y; Emteborg, H; Seghers, J; Robouch, P; de la Calle, M B

    2015-01-01

    The Institute for Reference Materials and Measurements (IRMM) of the Joint Research Centre (JRC), a Directorate General of the European Commission, operates the International Measurement Evaluation Program (IMEP). IMEP organises inter-laboratory comparisons in support of European Union policies. This paper presents the results of two proficiency tests (PTs): IMEP-116 and IMEP-39, organised for the determination of total Cd, Pb, As, Hg and inorganic As (iAs) in mushrooms. Participation in IMEP-116 was restricted to National Reference Laboratories (NRLs) officially appointed by national authorities in European Union member states. IMEP-39 was open to all other laboratories wishing to participate. Thirty-seven participants from 25 countries reported results in IMEP-116, and 62 laboratories from 36 countries reported for the IMEP-39 study. Both PTs were organised in support to Regulation (EC) No. 1881/2006, which sets the maximum levels for certain contaminants in food. The test item used in both PTs was a blend of mushrooms of the variety shiitake (Lentinula edodes). Five laboratories, with demonstrated measurement capability in the field, provided results to establish the assigned values (Xref). The standard uncertainties associated to the assigned values (uref) were calculated by combining the uncertainty of the characterisation (uchar) with a contribution for homogeneity (ubb) and for stability (ust), whilst uchar was calculated following ISO 13528. Laboratory results were rated with z- and zeta (ζ)-scores in accordance with ISO 13528. The standard deviation for proficiency assessment, σp, ranged from 10% to 20% depending on the analyte. The percentage of satisfactory z-scores ranged from 81% (iAs) to 97% (total Cd) in IMEP-116 and from 64% (iAs) to 84% (total Hg) in IMEP-39.

  5. CSF Aβ1-42 - an excellent but complicated Alzheimer's biomarker - a route to standardisation.

    PubMed

    Kuhlmann, Julia; Andreasson, Ulf; Pannee, Josef; Bjerke, Maria; Portelius, Erik; Leinenbach, Andreas; Bittner, Tobias; Korecka, Magdalena; Jenkins, Rand G; Vanderstichele, Hugo; Stoops, Erik; Lewczuk, Piotr; Shaw, Leslie M; Zegers, Ingrid; Schimmel, Heinz; Zetterberg, Henrik; Blennow, Kaj

    2017-04-01

    The 42 amino acid form of amyloid β (Aβ 1 - 42 ) in cerebrospinal fluid (CSF) has been widely accepted as a central biomarker for Alzheimer's disease. Several immunoassays for CSF Aβ 1-42 are commercially available, but can suffer from between laboratory and batch-to-batch variability as well as lack of standardisation across assays. As a consequence, no general cut-off values have been established for a specific context of use (e.g., clinical diagnostics) and selection of individuals for enrolment in clinical trials (patient stratification) remains challenging. The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) has initiated a working group for CSF proteins (WG-CSF) to facilitate standardisation of CSF Aβ 1-42 measurement results. The efforts of the IFCC WG-CSF include the development of certified reference materials (CRMs) and reference measurement procedures (RMPs) for key biomarkers. Two candidate RMPs for quantification of Aβ 1-42 in CSF based on liquid chromatography tandem mass spectrometry have been developed and tested in two ring trials. Furthermore, two commutability studies including native CSF pools, artificial CSF and spiked materials have been completed. On the basis of these studies, human CSF pools containing only endogenous Aβ 1-42 at three concentrations were selected as the format for future CRMs that are now being processed. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. U.S. Geological Survey Standard Reference Sample Project: Performance Evaluation of Analytical Laboratories

    USGS Publications Warehouse

    Long, H. Keith; Daddow, Richard L.; Farrar, Jerry W.

    1998-01-01

    Since 1962, the U.S. Geological Survey (USGS) has operated the Standard Reference Sample Project to evaluate the performance of USGS, cooperator, and contractor analytical laboratories that analyze chemical constituents of environmental samples. The laboratories are evaluated by using performance evaluation samples, called Standard Reference Samples (SRSs). SRSs are submitted to laboratories semi-annually for round-robin laboratory performance comparison purposes. Currently, approximately 100 laboratories are evaluated for their analytical performance on six SRSs for inorganic and nutrient constituents. As part of the SRS Project, a surplus of homogeneous, stable SRSs is maintained for purchase by USGS offices and participating laboratories for use in continuing quality-assurance and quality-control activities. Statistical evaluation of the laboratories results provides information to compare the analytical performance of the laboratories and to determine possible analytical deficiences and problems. SRS results also provide information on the bias and variability of different analytical methods used in the SRS analyses.

  7. Outgassing Data for Selecting Spacecraft Materials

    NASA Technical Reports Server (NTRS)

    Campbell, William A., Jr.; Scialdone, John J.

    1993-01-01

    This tenth compilation of outgassing data of materials intended for spacecraft use supersedes Reference Publication 1124, Revision 2, November 1990. The data were obtained at the Goddard Space Flight Center (GSFC), utilizing equipment developed at Stanford Research Institute (SRI) under contract to the Jet Propulsion Laboratory (JPL). SRI personnel developed an apparatus for determining the mass loss in vacuum and for collecting the outgassed products. The outgassing data have been presented in three different ways in order to facilitate material selection. In Section A, the materials are divided by category into the 18 probable uses, such as adhesives, greases, paints, potting compounds, and so forth. In Section B, all the materials contained in Section A are listed in alphabetical order by the manufacturer's identification. In Section C, the only materials listed are those having 'Total Mass Loss' (TML) and Collected Volatile Condensable Materials (CVCM) equal to or lower than a maximum 1.0 percent TML and a maximum 0.10 percent CVCM. These are grouped by use, as in Section A.

  8. [On the way to national reference system of laboratory medicine].

    PubMed

    Muravskaia, N P; Men'shikov, V V

    2014-10-01

    The application of standard samples and reference techniques of implementation of measurements is needed for a valid support of reliability of analyses applied in clinical diagnostic laboratories. They play role of landmarks under metrologic monitoring, calibration of devices and control of quality of results. The article presents analysis of shortcomings interfering with formation of national reference system in Russia harmonized with possibilities provided by international organizations. Among them are the joint Committee on metrologic monitoring in laboratory medicine under the auspices of the International Bureau of Weights and Measures, the International Federation of clinical chemistry and laboratory medicine, etc. The results of the recent development of national normative documents, standard samples and techniques assisted by the authors of article are considered. They are the first steps to organization of national reference system which would comprise all range of modern analytical technologies of laboratory medicine. The national and international measures are proposed to enhance the promptest resolving of task of organization of national reference system for laboratory medicine in the interests of increasing of effectiveness of medical care to citizen of Russia.

  9. Discrepancies in reporting the CAG repeat lengths for Huntington's disease

    PubMed Central

    Quarrell, Oliver W; Handley, Olivia; O'Donovan, Kirsty; Dumoulin, Christine; Ramos-Arroyo, Maria; Biunno, Ida; Bauer, Peter; Kline, Margaret; Landwehrmeyer, G Bernhard

    2012-01-01

    Huntington's disease results from a CAG repeat expansion within the Huntingtin gene; this is measured routinely in diagnostic laboratories. The European Huntington's Disease Network REGISTRY project centrally measures CAG repeat lengths on fresh samples; these were compared with the original results from 121 laboratories across 15 countries. We report on 1326 duplicate results; a discrepancy in reporting the upper allele occurred in 51% of cases, this reduced to 13.3% and 9.7% when we applied acceptable measurement errors proposed by the American College of Medical Genetics and the Draft European Best Practice Guidelines, respectively. Duplicate results were available for 1250 lower alleles; discrepancies occurred in 40% of cases. Clinically significant discrepancies occurred in 4.0% of cases with a potential unexplained misdiagnosis rate of 0.3%. There was considerable variation in the discrepancy rate among 10 of the countries participating in this study. Out of 1326 samples, 348 were re-analysed by an accredited diagnostic laboratory, based in Germany, with concordance rates of 93% and 94% for the upper and lower alleles, respectively. This became 100% if the acceptable measurement errors were applied. The central laboratory correctly reported allele sizes for six standard reference samples, blind to the known result. Our study differs from external quality assessment (EQA) schemes in that these are duplicate results obtained from a large sample of patients across the whole diagnostic range. We strongly recommend that laboratories state an error rate for their measurement on the report, participate in EQA schemes and use reference materials regularly to adjust their own internal standards. PMID:21811303

  10. Multilaboratory evaluation of methods for detecting enteric viruses in soils.

    PubMed Central

    Hurst, C J; Schaub, S A; Sobsey, M D; Farrah, S R; Gerba, C P; Rose, J B; Goyal, S M; Larkin, E P; Sullivan, R; Tierney, J T

    1991-01-01

    Two candidate methods for the recovery and detection of viruses in soil were subjected to round robin comparative testing by members of the American Society for Testing and Materials D19:24:04:04 Subcommittee Task Group. Selection of the methods, designated "Berg" and "Goyal," was based on results of an initial screening which indicated that both met basic criteria considered essential by the task group. Both methods utilized beef extract solutions to achieve desorption and recovery of viruses from representative soils: a fine sand soil, an organic muck soil, a sandy loam soil, and a clay loam soil. One of the two methods, Goyal, also used a secondary concentration of resulting soil eluants via low-pH organic flocculation to achieve a smaller final assay volume. Evaluation of the two methods was simultaneously performed in replicate by nine different laboratories. Each of the produced samples was divided into portions, and these were respectively subjected to quantitative viral plaque assay by both the individual, termed independent, laboratory which had done the soil processing and a single common reference laboratory, using a single cell line and passage level. The Berg method seemed to produce slightly higher virus recovery values; however, the differences in virus assay titers for samples produced by the two methods were not statistically significant (P less than or equal to 0.05) for any one of the four soils. Despite this lack of a method effect, there was a statistically significant laboratory effect exhibited by assay titers from the independent versus reference laboratories for two of the soils, sandy loam and clay loam. PMID:1849712

  11. Multilaboratory evaluation of methods for detecting enteric viruses in soils.

    PubMed

    Hurst, C J; Schaub, S A; Sobsey, M D; Farrah, S R; Gerba, C P; Rose, J B; Goyal, S M; Larkin, E P; Sullivan, R; Tierney, J T

    1991-02-01

    Two candidate methods for the recovery and detection of viruses in soil were subjected to round robin comparative testing by members of the American Society for Testing and Materials D19:24:04:04 Subcommittee Task Group. Selection of the methods, designated "Berg" and "Goyal," was based on results of an initial screening which indicated that both met basic criteria considered essential by the task group. Both methods utilized beef extract solutions to achieve desorption and recovery of viruses from representative soils: a fine sand soil, an organic muck soil, a sandy loam soil, and a clay loam soil. One of the two methods, Goyal, also used a secondary concentration of resulting soil eluants via low-pH organic flocculation to achieve a smaller final assay volume. Evaluation of the two methods was simultaneously performed in replicate by nine different laboratories. Each of the produced samples was divided into portions, and these were respectively subjected to quantitative viral plaque assay by both the individual, termed independent, laboratory which had done the soil processing and a single common reference laboratory, using a single cell line and passage level. The Berg method seemed to produce slightly higher virus recovery values; however, the differences in virus assay titers for samples produced by the two methods were not statistically significant (P less than or equal to 0.05) for any one of the four soils. Despite this lack of a method effect, there was a statistically significant laboratory effect exhibited by assay titers from the independent versus reference laboratories for two of the soils, sandy loam and clay loam.

  12. Development of an evidence-based approach to external quality assurance for breast cancer hormone receptor immunohistochemistry: comparison of reference values.

    PubMed

    Makretsov, Nikita; Gilks, C Blake; Alaghehbandan, Reza; Garratt, John; Quenneville, Louise; Mercer, Joel; Palavdzic, Dragana; Torlakovic, Emina E

    2011-07-01

    External quality assurance and proficiency testing programs for breast cancer predictive biomarkers are based largely on traditional ad hoc design; at present there is no universal consensus on definition of a standard reference value for samples used in external quality assurance programs. To explore reference values for estrogen receptor and progesterone receptor immunohistochemistry in order to develop an evidence-based analytic platform for external quality assurance. There were 31 participating laboratories, 4 of which were previously designated as "expert" laboratories. Each participant tested a tissue microarray slide with 44 breast carcinomas for estrogen receptor and progesterone receptor and submitted it to the Canadian Immunohistochemistry Quality Control Program for analysis. Nuclear staining in 1% or more of the tumor cells was a positive score. Five methods for determining reference values were compared. All reference values showed 100% agreement for estrogen receptor and progesterone receptor scores, when indeterminate results were excluded. Individual laboratory performance (agreement rates, test sensitivity, test specificity, positive predictive value, negative predictive value, and κ value) was very similar for all reference values. Identification of suboptimal performance by all methods was identical for 30 of 31 laboratories. Estrogen receptor assessment of 1 laboratory was discordant: agreement was less than 90% for 3 of 5 reference values and greater than 90% with the use of 2 other reference values. Various reference values provide equivalent laboratory rating. In addition to descriptive feedback, our approach allows calculation of technical test sensitivity and specificity, positive and negative predictive values, agreement rates, and κ values to guide corrective actions.

  13. Hazardous materials: chemistry and safe handling aspects of flammable, toxic and radioactive materials. A course of study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, M.W.

    1983-01-01

    The subject of this dissertation is a one semester, three credit course designed for students who have taken at least twelve credits college chemistry, and for high school teachers as a continuing education course. The need for such a course arises from the increased concern for safety in recent years and the introduction of many regulations of which the working chemist should be aware, notably those issued by the Occupational Safety and Health Administration. A few colleges have recently started to offer courses in laboratory safety to undergraduate and graduate chemistry students. Thus, there is a need for the developmentmore » of courses in which chemical safety is taught. This course is divided into three units: 1) flammable materials; 2) toxic materials; and 3) radioactive materials. Each unit is self contained and could be taught separately as a one credit course. The material necessary for lecture presentation is given in the text of this dissertation: there are about seven topics in each unit. The chemical properties of selected substances are emphasized. Examples of governmental regulations are given, and there are sample examination questions for each unit and homework assignments that require the use of reference sources. Laboratory exercises are included to enable students to gain experience in the safe handling of hazardous chemicals and of some equipment and instruments used to analyze and study flammable, toxic and radioactive materials.« less

  14. An Integrated RFID and Barcode Tagged Item Inventory System for Deployment at New Brunswick Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Younkin, James R; Kuhn, Michael J; Gradle, Colleen

    New Brunswick Laboratory (NBL) has a numerous inventory containing thousands of plutonium and uranium certified reference materials. The current manual inventory process is well established but is a lengthy process which requires significant oversight and double checking to ensure correctness. Oak Ridge National Laboratory has worked with NBL to develop and deploy a new inventory system which utilizes handheld computers with barcode scanners and radio frequency identification (RFID) readers termed the Tagged Item Inventory System (TIIS). Certified reference materials are identified by labels which incorporate RFID tags and barcodes. The label printing process and RFID tag association process are integratedmore » into the main desktop software application. Software on the handheld computers syncs with software on designated desktop machines and the NBL inventory database to provide a seamless inventory process. This process includes: 1) identifying items to be inventoried, 2) downloading the current inventory information to the handheld computer, 3) using the handheld to read item and location labels, and 4) syncing the handheld computer with a designated desktop machine to analyze the results, print reports, etc. The security of this inventory software has been a major concern. Designated roles linked to authenticated logins are used to control access to the desktop software while password protection and badge verification are used to control access to the handheld computers. The overall system design and deployment at NBL will be presented. The performance of the system will also be discussed with respect to a small piece of the overall inventory. Future work includes performing a full inventory at NBL with the Tagged Item Inventory System and comparing performance, cost, and radiation exposures to the current manual inventory process.« less

  15. Laser based water equilibration method for d18O determination of water samples

    NASA Astrophysics Data System (ADS)

    Mandic, Magda; Smajgl, Danijela; Stoebener, Nils

    2017-04-01

    Determination of d18O with water equilibration method using mass spectrometers equipped with equilibration unit or Gas Bench is known already for many years. Now, with development of laser spectrometers this extends methods and possibilities to apply different technologies in laboratory but also in the field. The Thermo Scientific™ Delta Ray™ Isotope Ratio Infrared Spectrometer (IRIS) analyzer with the Universal Reference Interface (URI) Connect and Teledyne Cetac ASX-7100 offers high precision and throughput of samples. It employs optical spectroscopy for continuous measurement of isotope ratio values and concentration of carbon dioxide in ambient air, and also for analysis of discrete samples from vials, syringes, bags, or other user-provided sample containers. Test measurements and conformation of precision and accuracy of method determination d18O in water samples were done in Thermo Fisher application laboratory with three lab standards, namely ANST, Ocean II and HBW. All laboratory standards were previously calibrated with international reference material VSMOW2 and SLAP2 to assure accuracy of the isotopic values of the water. With method that we present in this work achieved repeatability and accuracy are 0.16‰ and 0.71‰, respectively, which fulfill requirements of regulatory method for wine and must after equilibration with CO2.

  16. Estrogen and progesterone receptor testing in breast carcinoma: concordance of results between local and reference laboratories in Brazil.

    PubMed

    Wludarski, Sheila Cristina Lordelo; Lopes, Lisandro Ferreira; Duarte, Ivison Xavier; Carvalho, Filomena Marino; Weiss, Lawrence; Bacchi, Carlos Eduardo

    2011-01-01

    Breast cancer accounts for approximately one quarter of all cancers in females. Estrogen and progesterone receptor testing has become an essential part of the clinical evaluation of breast carcinoma patients, and accurate results are critical in identifying patients who may benefit from hormone therapy. The present study had the aim of investigating the concordance of the results from hormone receptor tests between a reference laboratory and local (or community) laboratories in Brazil. Retrospective study at a reference pathology laboratory. The concordance in the results from hormone receptor tests between a reference laboratory and 146 local laboratories in Brazil was compared in relation to 500 invasive breast carcinoma cases, using immunohistochemistry. There was concordance in 89.4% (447/500 cases) and 85.0% (425/500 cases) of the results from estrogen (κ = 0.744, P < 0.001) and progesterone (κ = 0.688, P < 0.001) receptor tests, respectively, between local and reference laboratories. This was similar to findings in other countries. The false negative rates from estrogen and progesterone receptor tests in local laboratories were 8.7% and 14.4%, respectively. The false positive rates from estrogen and progesterone receptor tests in local laboratories were 15.5% and 16.0%, respectively. Technical and result interpretation issues may explain most of the discordances in hormone receptor testing in local laboratories. Validation of estrogen and progesterone receptor tests at local laboratories, with rigorous quality control measures, is strongly recommended in order to avoid erroneous treatment of breast cancer patients.

  17. Estimating equations for glomerular filtration rate in the era of creatinine standardization: a systematic review.

    PubMed

    Earley, Amy; Miskulin, Dana; Lamb, Edmund J; Levey, Andrew S; Uhlig, Katrin

    2012-06-05

    Clinical laboratories are increasingly reporting estimated glomerular filtration rate (GFR) by using serum creatinine assays traceable to a standard reference material. To review the performance of GFR estimating equations to inform the selection of a single equation by laboratories and the interpretation of estimated GFR by clinicians. A systematic search of MEDLINE, without language restriction, between 1999 and 21 October 2011. Cross-sectional studies in adults that compared the performance of 2 or more creatinine-based GFR estimating equations with a reference GFR measurement. Eligible equations were derived or reexpressed and validated by using creatinine measurements traceable to the standard reference material. Reviewers extracted data on study population characteristics, measured GFR, creatinine assay, and equation performance. Eligible studies compared the MDRD (Modification of Diet in Renal Disease) Study and CKD-EPI (Chronic Kidney Disease Epidemiology Collaboration) equations or modifications thereof. In 12 studies in North America, Europe, and Australia, the CKD-EPI equation performed better at higher GFRs (approximately >60 mL/min per 1.73 m(2)) and the MDRD Study equation performed better at lower GFRs. In 5 of 8 studies in Asia and Africa, the equations were modified to improve their performance by adding a coefficient derived in the local population or removing a coefficient. Methods of GFR measurement and study populations were heterogeneous. Neither the CKD-EPI nor the MDRD Study equation is optimal for all populations and GFR ranges. Using a single equation for reporting requires a tradeoff to optimize performance at either higher or lower GFR ranges. A general practice and public health perspective favors the CKD-EPI equation. Kidney Disease: Improving Global Outcomes.

  18. A new organic reference material, L-glutamic acid, USGS41a, for δ13C and δ15N measurements − a replacement for USGS41

    USGS Publications Warehouse

    Qi, Haiping; Coplen, Tyler B.; Mroczkowski, Stanley J.; Brand, Willi A.; Brandes, Lauren; Geilmann, Heike; Schimmelmann, Arndt

    2016-01-01

    RationaleThe widely used l-glutamic acid isotopic reference material USGS41, enriched in both 13C and 15N, is nearly exhausted. A new material, USGS41a, has been prepared as a replacement for USGS41.MethodsUSGS41a was prepared by dissolving analytical grade l-glutamic acid enriched in 13C and 15N together with l-glutamic acid of normal isotopic composition. The δ13C and δ15N values of USGS41a were directly or indirectly normalized with the international reference materials NBS 19 calcium carbonate (δ13CVPDB = +1.95 mUr, where milliurey = 0.001 = 1 ‰), LSVEC lithium carbonate (δ13CVPDB = −46.6 mUr), and IAEA-N-1 ammonium sulfate (δ15NAir = +0.43 mUr) and USGS32 potassium nitrate (δ15N = +180 mUr exactly) by on-line combustion, continuous-flow isotope-ratio mass spectrometry, and off-line dual-inlet isotope-ratio mass spectrometry.ResultsUSGS41a is isotopically homogeneous; the reproducibility of δ13C and δ15N is better than 0.07 mUr and 0.09 mUr, respectively, in 200-μg amounts. It has a δ13C value of +36.55 mUr relative to VPDB and a δ15N value of +47.55 mUr relative to N2 in air. USGS41 was found to be hydroscopic, probably due to the presence of pyroglutamic acid. Experimental results indicate that the chemical purity of USGS41a is substantially better than that of USGS41.ConclusionsThe new isotopic reference material USGS41a can be used with USGS40 (having a δ13CVPDB value of −26.39 mUr and a δ15NAir value of −4.52 mUr) for (i) analyzing local laboratory isotopic reference materials, and (ii) quantifying drift with time, mass-dependent isotopic fractionation, and isotope-ratio-scale contraction for isotopic analysis of biological and organic materials. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA.

  19. A new organic reference material, l-glutamic acid, USGS41a, for δ(13) C and δ(15) N measurements - a replacement for USGS41.

    PubMed

    Qi, Haiping; Coplen, Tyler B; Mroczkowski, Stanley J; Brand, Willi A; Brandes, Lauren; Geilmann, Heike; Schimmelmann, Arndt

    2016-04-15

    The widely used l-glutamic acid isotopic reference material USGS41, enriched in both (13) C and (15) N, is nearly exhausted. A new material, USGS41a, has been prepared as a replacement for USGS41. USGS41a was prepared by dissolving analytical grade l-glutamic acid enriched in (13) C and (15) N together with l-glutamic acid of normal isotopic composition. The δ(13) C and δ(15) N values of USGS41a were directly or indirectly normalized with the international reference materials NBS 19 calcium carbonate (δ(13) CVPDB = +1.95 mUr, where milliurey = 0.001 = 1 ‰), LSVEC lithium carbonate (δ(13) CVPDB = -46.6 mUr), and IAEA-N-1 ammonium sulfate (δ(15) NAir = +0.43 mUr) and USGS32 potassium nitrate (δ(15) N = +180 mUr exactly) by on-line combustion, continuous-flow isotope-ratio mass spectrometry, and off-line dual-inlet isotope-ratio mass spectrometry. USGS41a is isotopically homogeneous; the reproducibility of δ(13) C and δ(15) N is better than 0.07 mUr and 0.09 mUr, respectively, in 200-μg amounts. It has a δ(13) C value of +36.55 mUr relative to VPDB and a δ(15) N value of +47.55 mUr relative to N2 in air. USGS41 was found to be hydroscopic, probably due to the presence of pyroglutamic acid. Experimental results indicate that the chemical purity of USGS41a is substantially better than that of USGS41. The new isotopic reference material USGS41a can be used with USGS40 (having a δ(13) CVPDB value of -26.39 mUr and a δ(15) NAir value of -4.52 mUr) for (i) analyzing local laboratory isotopic reference materials, and (ii) quantifying drift with time, mass-dependent isotopic fractionation, and isotope-ratio-scale contraction for isotopic analysis of biological and organic materials. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA.

  20. Age-related reference intervals for free and total prostate-specific antigen in a Singaporean population.

    PubMed

    Saw, S; Aw, T C

    2000-11-01

    Cancer of the prostate is the sixth most frequently found cancer in Singapore. Prostate-specific antigen (PSA) is the most clinically useful tumour marker available today for the diagnosis and management of prostate cancer. To enhance the value of PSA as a screening test we developed age-specific intervals for our ethnic population. The measurement of free PSA was included in the study to calculate the free:total ratio which enhances the differential diagnosis of prostate cancer from benign prostatic hyperplasia or prostatitis. The total PSA upper limits of 10-year intervals, beginning at 30-years-old, were 1.4, 1.7, 2.3, 4.0, 6.3 and 6.6 microg/l. Free PSA cut-off limits were 0.4, 0.5, 0.5, 1.0, 1.5 and 1.6 microg/l. The free:total ratio of PSA was not age dependent. Abbott AxSym standardised their calibration material for both free and total PSA assays with the Stanford 90:10 reference material. This laboratory has implemented these age-specific reference intervals and are currently following up their pick-up rate in the detection of prostate cancer.

  1. Determination of serum calcium levels by 42Ca isotope dilution inductively coupled plasma mass spectrometry.

    PubMed

    Han, Bingqing; Ge, Menglei; Zhao, Haijian; Yan, Ying; Zeng, Jie; Zhang, Tianjiao; Zhou, Weiyan; Zhang, Jiangtao; Wang, Jing; Zhang, Chuanbao

    2017-11-27

    Serum calcium level is an important clinical index that reflects pathophysiological states. However, detection accuracy in laboratory tests is not ideal; as such, a high accuracy method is needed. We developed a reference method for measuring serum calcium levels by isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS), using 42Ca as the enriched isotope. Serum was digested with 69% ultrapure nitric acid and diluted to a suitable concentration. The 44Ca/42Ca ratio was detected in H2 mode; spike concentration was calibrated by reverse IDMS using standard reference material (SRM) 3109a, and sample concentration was measured by a bracketing procedure. We compared the performance of ID ICP-MS with those of three other reference methods in China using the same serum and aqueous samples. The relative expanded uncertainty of the sample concentration was 0.414% (k=2). The range of repeatability (within-run imprecision), intermediate imprecision (between-run imprecision), and intra-laboratory imprecision were 0.12%-0.19%, 0.07%-0.09%, and 0.16%-0.17%, respectively, for two of the serum samples. SRM909bI, SRM909bII, SRM909c, and GBW09152 were found to be within the certified value interval, with mean relative bias values of 0.29%, -0.02%, 0.10%, and -0.19%, respectively. The range of recovery was 99.87%-100.37%. Results obtained by ID ICP-MS showed a better accuracy than and were highly correlated with those of other reference methods. ID ICP-MS is a simple and accurate candidate reference method for serum calcium measurement and can be used to establish and improve serum calcium reference system in China.

  2. Practical aspects of genetic identification of hallucinogenic and other poisonous mushrooms for clinical and forensic purposes

    PubMed Central

    Kowalczyk, Marek; Sekuła, Andrzej; Mleczko, Piotr; Olszowy, Zofia; Kujawa, Anna; Zubek, Szymon; Kupiec, Tomasz

    2015-01-01

    Aim To assess the usefulness of a DNA-based method for identifying mushroom species for application in forensic laboratory practice. Methods Two hundred twenty-one samples of clinical forensic material (dried mushrooms, food remains, stomach contents, feces, etc) were analyzed. ITS2 region of nuclear ribosomal DNA (nrDNA) was sequenced and the sequences were compared with reference sequences collected from the National Center for Biotechnology Information gene bank (GenBank). Sporological identification of mushrooms was also performed for 57 samples of clinical material. Results Of 221 samples, positive sequencing results were obtained for 152 (69%). The highest percentage of positive results was obtained for samples of dried mushrooms (96%) and food remains (91%). Comparison with GenBank sequences enabled identification of all samples at least at the genus level. Most samples (90%) were identified at the level of species or a group of closely related species. Sporological and molecular identification were consistent at the level of species or genus for 30% of analyzed samples. Conclusion Molecular analysis identified a larger number of species than sporological method. It proved to be suitable for analysis of evidential material (dried hallucinogenic mushrooms) in forensic genetic laboratories as well as to complement classical methods in the analysis of clinical material. PMID:25727040

  3. Practical aspects of genetic identification of hallucinogenic and other poisonous mushrooms for clinical and forensic purposes.

    PubMed

    Kowalczyk, Marek; Sekuła, Andrzej; Mleczko, Piotr; Olszowy, Zofia; Kujawa, Anna; Zubek, Szymon; Kupiec, Tomasz

    2015-02-01

    To assess the usefulness of a DNA-based method for identifying mushroom species for application in forensic laboratory practice. Two hundred twenty-one samples of clinical forensic material (dried mushrooms, food remains, stomach contents, feces, etc) were analyzed. ITS2 region of nuclear ribosomal DNA (nrDNA) was sequenced and the sequen-ces were compared with reference sequences collected from the National Center for Biotechnology Information gene bank (GenBank). Sporological identification of mushrooms was also performed for 57 samples of clinical material. Of 221 samples, positive sequencing results were obtained for 152 (69%). The highest percentage of positive results was obtained for samples of dried mushrooms (96%) and food remains (91%). Comparison with GenBank sequences enabled identification of all samples at least at the genus level. Most samples (90%) were identified at the level of species or a group of closely related species. Sporological and molecular identification were consistent at the level of species or genus for 30% of analyzed samples. Molecular analysis identified a larger number of species than sporological method. It proved to be suitable for analysis of evidential material (dried hallucinogenic mushrooms) in forensic genetic laboratories as well as to complement classical methods in the analysis of clinical material.

  4. Comparing results of X-ray diffraction, µ-Raman spectroscopy and neutron diffraction when identifying chemical phases in seized nuclear material, during a comparative nuclear forensics exercise.

    PubMed

    Rondahl, Stina Holmgren; Pointurier, Fabien; Ahlinder, Linnea; Ramebäck, Henrik; Marie, Olivier; Ravat, Brice; Delaunay, François; Young, Emma; Blagojevic, Ned; Hester, James R; Thorogood, Gordon; Nelwamondo, Aubrey N; Ntsoane, Tshepo P; Roberts, Sarah K; Holliday, Kiel S

    2018-01-01

    This work presents the results for identification of chemical phases obtained by several laboratories as a part of an international nuclear forensic round-robin exercise. In this work powder X-ray diffraction (p-XRD) is regarded as the reference technique. Neutron diffraction produced a superior high-angle diffraction pattern relative to p-XRD. Requiring only small amounts of sample, µ-Raman spectroscopy was used for the first time in this context as a potentially complementary technique to p-XRD. The chemical phases were identified as pure UO 2 in two materials, and as a mixture of UO 2 , U 3 O 8 and an intermediate species U 3 O 7 in the third material.

  5. Characterization of low concentration uranium glass working materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eppich, G. R.; Wimpenny, J. B.; Leever, M. E.

    A series of uranium-doped silicate glasses were created at (Lawrence Livermore National Laboratory) LLNL, to be used as working reference material analogs for low uranium concentration research. Specifically, the aim of this effort was the generation of well-characterized glasses spanning a range of concentrations and compositions, and of sufficient homogeneity in uranium concentration and isotopic composition, for instrumentation research and development purposes. While the glasses produced here are not intended to replace or become standard materials for uranium concentration or uranium isotopic composition, it is hoped that they will help fill a current gap, providing low-level uranium glasses sufficient formore » methods development and method comparisons within the limitations of the produced glass suite. Glasses are available for research use by request.« less

  6. Iodine Standard Materials: Preparation and Inter-Laboratory Comparisons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D D Jenson; M L Adamic; J E Olson

    The Idaho National Laboratory is preparing to enter the community of AMS practioners who analyze for 129Iodine. We expect to take delivery of a 0.5 MV compact accelerator mass spectrometry system, built by NEC, in the early summer of 2014. The primary mission for this instrument is iodine; it is designed to analyze iodine in the +3 charge state. As part of the acceptance testing for this instrument, both at NEC and on-site in our laboratory, some sort of standard or reference material is needed to verify performance. Appropriate standard materials are not readily available in the commercial marketplace. Smallmore » quantities can sometimes be acquired from other laboratories already engaged in iodine analyses. In the longer-term, meaningful quantities of standard materials are needed for routine use in analyses, and for quality control functions1. We have prepared some standard materials, starting with elemental Woodward iodine and NIST SRM 3231 [Iodine-129 Isotopic Standard (high level)] 10-6 solution. The goal was to make mixtures at the 5x10-10, 5x10-11, 5x10-12 ratio levels, along with some unmodified Woodward, in the chemical form of silver iodide. Approximately twenty grams of each of these mixtures were prepared. The elemental Woodward iodine was dissolved in chloroform, then reduced to iodide using sodium bisulfite in water. At this point the NIST spike material was added, in the form of sodium iodide. The mixed iodides were oxidized back to iodine in chloroform using hydrogen peroxide. This oxidation step was essential for isotopic equilibration of the 127 and 129 atoms. The iodine was reduced to iodide using sodium bisulfite as before. Excess sulfites and sulfates were precipitated with barium nitrate. After decanting, silver nitrate was used to precipitate the desired silver iodide. Once the silver iodide was produced, the material was kept in darkness as much as possible to minimize photo-oxidation. The various mixtures were synthesized independently of each other; there were no serial dilutions involved. Aliquots of these four materials have been submitted to five established AMS laboratories where iodine analyses are routinely performed: ETH (Zurich), CNA (Seville), PRIME (Purdue), LLNL (California), and Isotrace (Toronto.) Results from four of these laboratories have been received; in general they indicate that the desired 129/127 ratios have been achieved. We will discuss the results of this informal round-robin exercise. If the installation of the instrument in Idaho goes well, we may have some very preliminary results from the new system. An integral part of data reporting is the approach to data reduction. Accordingly, there will also be some discussion of various philosophies of data handling in regard to the use of standards to adjust data, and background subtraction.« less

  7. Progress toward the determination of correct classification rates in fire debris analysis.

    PubMed

    Waddell, Erin E; Song, Emma T; Rinke, Caitlin N; Williams, Mary R; Sigman, Michael E

    2013-07-01

    Principal components analysis (PCA), linear discriminant analysis (LDA), and quadratic discriminant analysis (QDA) were used to develop a multistep classification procedure for determining the presence of ignitable liquid residue in fire debris and assigning any ignitable liquid residue present into the classes defined under the American Society for Testing and Materials (ASTM) E 1618-10 standard method. A multistep classification procedure was tested by cross-validation based on model data sets comprised of the time-averaged mass spectra (also referred to as total ion spectra) of commercial ignitable liquids and pyrolysis products from common building materials and household furnishings (referred to simply as substrates). Fire debris samples from laboratory-scale and field test burns were also used to test the model. The optimal model's true-positive rate was 81.3% for cross-validation samples and 70.9% for fire debris samples. The false-positive rate was 9.9% for cross-validation samples and 8.9% for fire debris samples. © 2013 American Academy of Forensic Sciences.

  8. Durability of a continuous strand mat polymeric composite for automotive structural applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Corum, J.M.; McCoy, H.E. Jr.; Ruggles, M.B.

    1995-12-31

    A key unanswered question that must be addressed before polymeric composites will be widely used in automotive structural components is their durability. Major durability issues are the effects of cyclic loadings, creep, automotive environments, and low-energy impacts on dimensional stability, strength, and stiffness. The U.S. Department of Energy is sponsoring a project at Oak Ridge National Laboratory to address these issues and to develop, in cooperation with the Automotive Composites Consortium, experimentally based, durability driven, design guidelines. The initial reference material is an isocyanurate reinforced with a continuous strand, swirl glass mat. This paper describes the basic deformation and failuremore » behavior of the reference material, and it presents test results illustrating the property degradations caused by loading, time, and environmental effects. The importance of characterizing and understanding damage and how it leads to failure is also discussed. The results presented are from the initial phases of an ongoing project. The ongoing effort and plans are briefly described.« less

  9. The effect of the low Earth orbit environment on space solar cells: Results of the advanced photovoltaic experiment (S0014)

    NASA Technical Reports Server (NTRS)

    Brinker, David J.; Hickey, John R.

    1992-01-01

    The Advanced Photovoltaic Experiment (APEX), containing over 150 solar cells and sensors, was designed to generate laboratory reference standards as well as to explore the durability of a wide variety of space solar cells. Located on the leading edge of the Long Duration Exposure Facility (LDEF), APEX received the maximum possible dosage of atomic oxygen and ultraviolet radiation, as well as enormous numbers of impacts from micrometeoroids and debris. The effect of the low earth orbital (LEO) environment on the solar cells and materials of APEX will be discussed in this paper. The on-orbit performance of the solar cells, as well as a comparison of pre- and postflight laboratory performance measurements, will be presented.

  10. Marine anthropogenic radiotracers in the Southern Hemisphere: New sampling and analytical strategies

    NASA Astrophysics Data System (ADS)

    Levy, I.; Povinec, P. P.; Aoyama, M.; Hirose, K.; Sanchez-Cabeza, J. A.; Comanducci, J.-F.; Gastaud, J.; Eriksson, M.; Hamajima, Y.; Kim, C. S.; Komura, K.; Osvath, I.; Roos, P.; Yim, S. A.

    2011-04-01

    The Japan Agency for Marine Earth Science and Technology conducted in 2003-2004 the Blue Earth Global Expedition (BEAGLE2003) around the Southern Hemisphere Oceans, which was a rare opportunity to collect many seawater samples for anthropogenic radionuclide studies. We describe here sampling and analytical methodologies based on radiochemical separations of Cs and Pu from seawater, as well as radiometric and mass spectrometry measurements. Several laboratories took part in radionuclide analyses using different techniques. The intercomparison exercises and analyses of certified reference materials showed a reasonable agreement between the participating laboratories. The obtained data on the distribution of 137Cs and plutonium isotopes in seawater represent the most comprehensive results available for the Southern Hemisphere Oceans.

  11. Serum PCB levels and congener profiles among US construction workers

    PubMed Central

    Herrick, Robert F; Meeker, John D; Hauser, Russ; Altshul, Larisa; Weymouth, George A

    2007-01-01

    Background The presence of PCB in caulking (sealant) material found in masonry buildings has been well-documented in several countries. A recent investigation of 24 buildings in the greater Boston area found that 8 buildings had high PCB levels in caulking materials used around window frames and in joints between masonry blocks. Workers removing caulking material have been shown to have elevated serum PCB levels. Methods This project compared serum PCB levels among male workers who installed and/or removed PCB-containing caulking material from buildings in the greater Boston area with reference serum PCB levels from 358 men from the same area. Serum PCB levels were measured in the same laboratory by liquid-liquid extraction, column chromatography clean-up and dual capillary column GC/microECD analysis. Results When the congener profiles were compared between the reference population and the construction workers, the serum levels of the more volatile, lighter PCBs (di-, tri-and tetrachloro, sum of IUPAC# 6–74) were substantially higher among the construction workers. One of the youngest workers had the lowest total serum PCB levels (sum of 57 congeners) of all 6 workers, but the contribution of more volatile (less chlorinated) PCB congeners (#16, 26,28,33,74,66, and 60) was markedly higher than in other 5 workers and reference men. Only this worker was working on a job that involved removing PCB caulking at the time of the blood sampling. Conclusion While the results of this pilot study are based upon small numbers (6 construction workers who handled PCB caulking), the serum PCB levels among the construction workers exceed the referents. Comparison of the congener profiles suggests that there are substantial differences between the construction workers and the general population samples. These differences, and the similarities of profiles among the construction workers strongly suggest that occupational contact with caulking material can be a major source of PCB exposure for construction workers. PMID:17764566

  12. Hematological reference values of healthy Malaysian population.

    PubMed

    Roshan, T M; Rosline, H; Ahmed, S A; Rapiaah, M; Wan Zaidah, A; Khattak, M N

    2009-10-01

    Health and disease can only be distinguished by accurate and reliable reference values of a particular laboratory test. It is now a proven fact that there is considerable variation in hematology reference intervals depending on the demographic and preanalytical variables. There are evidences that values provided by manufacturers do not have appropriate application for all populations. Moreover, reference ranges provided by different laboratory manuals and books also do not solve this problem. We are presenting here normal reference ranges of Malaysian population. These values were determined by using Sysmex XE-2100 and ACL 9000 hematology and coagulation analyzers. Results from this study showed that there were considerable differences in the reference values from manufacturers, western population or laboratory manuals compared with those from the local population.

  13. Bias Assessment of General Chemistry Analytes using Commutable Samples.

    PubMed

    Koerbin, Gus; Tate, Jillian R; Ryan, Julie; Jones, Graham Rd; Sikaris, Ken A; Kanowski, David; Reed, Maxine; Gill, Janice; Koumantakis, George; Yen, Tina; St John, Andrew; Hickman, Peter E; Simpson, Aaron; Graham, Peter

    2014-11-01

    Harmonisation of reference intervals for routine general chemistry analytes has been a goal for many years. Analytical bias may prevent this harmonisation. To determine if analytical bias is present when comparing methods, the use of commutable samples, or samples that have the same properties as the clinical samples routinely analysed, should be used as reference samples to eliminate the possibility of matrix effect. The use of commutable samples has improved the identification of unacceptable analytical performance in the Netherlands and Spain. The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) has undertaken a pilot study using commutable samples in an attempt to determine not only country specific reference intervals but to make them comparable between countries. Australia and New Zealand, through the Australasian Association of Clinical Biochemists (AACB), have also undertaken an assessment of analytical bias using commutable samples and determined that of the 27 general chemistry analytes studied, 19 showed sufficiently small between method biases as to not prevent harmonisation of reference intervals. Application of evidence based approaches including the determination of analytical bias using commutable material is necessary when seeking to harmonise reference intervals.

  14. MTRETR MAINTENANCE SHOP, TRA653. FLOOR PLAN FOR FIRST FLOOR: MACHINE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    MTR-ETR MAINTENANCE SHOP, TRA-653. FLOOR PLAN FOR FIRST FLOOR: MACHINE SHOP, ELECTRICAL AND INSTRUMENT SHOP, TOOL CRIB, ELECTRONIC SHOP, LOCKER ROOM, SPECIAL TEMPERATURE CONTROLLED ROOM, AND OFFICES. "NEW" ON DRAWING REFERS TO REVISION OF 11/1956 DRAWING ON WHICH AREAS WERE DESIGNATED AS "FUTURE." HUMMEL HUMMEL & JONES 810-MTR-ETR-653-A-7, 5/1957. INL INDEX NO. 532-0653-00-381-101839, REV. 2. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  15. Effects of Peripheral Architecture on the Properties of Aryl Polyhedral Oligomeric Silsesquioxanes

    DTIC Science & Technology

    2012-07-26

    POSS) molecules are described. These POSS materials were synthesized in our laboratory and characterized by single-crystal and powder X - ray diffraction ...powder X - ray diffraction (XRD), where applicable. 1H, 13C, and 29Si NMR spectra were obtained on Bruker 300 and 400 MHz spectrometers using 5 mm o.d...degree of cage ordering during precipitation. Referring back to Figure 14, strong X - ray scattering peaks in the spectra for 1 in the d- spacing range

  16. Technical Basis Document for Internal Dosimetry at Sandia National Laboratories Revision 2.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Potter, Charles A.

    2014-09-01

    The RPID Project will be implemented at all SNL facilities for activities involving the processing and/or storing of radioactive materials. This project includes activities at the Tech Area (TA) I, TA II, TA III, TA IV, TA V, Coyote Test Field, and environmental restoration sites at SNL, located in Albuquerque, New Mexico, and the Kauai Test Facility(SNL/KTF). Reference to SNL throughout this document includes facilities and activities at the Albuquerque location and at SNL/KTF.

  17. A UK NEQAS ICC and ISH multicentre study using the Kreatech Poseidon HER2 FISH probe: intersite variation can be rigorously controlled using FISH.

    PubMed

    Bartlett, John M S; Campbell, Fiona M; Ibrahim, Merdol; Thomas, Jeremy; Wencyk, Pete; Ellis, Ian; Kay, Elaine; Connolly, Yvonne; O'Grady, Anthony; Barnett, Sarah; Starczynski, Jane; Cunningham, Paul; Miller, Keith

    2010-02-01

    To assess a new HER2 fluorescence in situ hybridization (FISH) test and report on multicentre intrasite and intersite variation. HER2 results were scored from 45 breast cancers in eight laboratories using the Kreatech Poseidon HER2 FISH probe (Kreatech Diagnostics, Amsterdam, the Netherlands). Overall, 80.9% of cores were successfully analysed. Mean intrasite variation for HER2 ratio assessment was low (4.74%). Intersite variation in ratio was in line with previous reports (11.9+/-0.8%) for both reference and non-reference laboratories; only one laboratory displayed significantly higher intersite variation (P=0.009) than the remaining seven laboratories. The overall incidence of misclassification of cores was <1.3%, demonstrating an excellent level of concordance (>98.7%) across all eight laboratories, irrespective of whether they were 'reference' or 'routine diagnostic' laboratories. The Kreatech Poseidon HER2 FISH test is robust and reproducible. Highly quantitatively reproducible FISH results were obtained from eight 'diagnostic' and 'reference' laboratories; however, continued quality assessments are essential to good performance.

  18. UO 2 Particle Standards: Synthesis, Purification & Planchet Preparation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barrett, Christopher A.; Anheier, Norman C.

    2016-03-31

    The IAEA has previously indicated its desire for reliable provision of suitable reference materials in support of environmental sample analysis and sustained advancement at the Department of Safeguards, as laid out in the Long Term R&D plan (LTRD 10.1 & 10.2). In a recent meeting between NPAC, the IAEA and PNNL, this pressing need was directly outlined by the IAEA as having two main objectives. The first pertains to current operations, such as instrument calibrations and evaluation of bias across the Network of Analytical Laboratories and requires particles on the order of 300-500 nm in diameter. The second need formore » particle reference material would directly support the IAEA’s ongoing R&D efforts and calls for smaller particles ranging from 50 -100 nm in size. As such, the IAEA has expressed a great deal of interest in the newly established synthesis capabilities at PNNL, initially cultivated through a PNNL LDRD project to address the particle-standards shortcomings for uranium oxide material. The joint meeting concluded with a request by the IAEA for 1-2 planchet samples containing PNNL’s UO 2 particulate material, to be delivered in the near-term. This report outlines the steps taken to meet that request and includes some basic characteristics of the samples sent to the IAEA.« less

  19. Remote sensing characterization of the Animas River watershed, southwestern Colorado, by AVIRIS imaging spectroscopy

    USGS Publications Warehouse

    Dalton, J.B.; Bove, D.J.; Mladinich, C.S.

    2005-01-01

    Visible-wavelength and near-infrared image cubes of the Animas River watershed in southwestern Colorado have been acquired by the Jet Propulsion Laboratory's Airborne Visible and InfraRed Imaging Spectrometer (AVIRIS) instrument and processed using the U.S. Geological Survey Tetracorder v3.6a2 implementation. The Tetracorder expert system utilizes a spectral reference library containing more than 400 laboratory and field spectra of end-member minerals, mineral mixtures, vegetation, manmade materials, atmospheric gases, and additional substances to generate maps of mineralogy, vegetation, snow, and other material distributions. Major iron-bearing, clay, mica, carbonate, sulfate, and other minerals were identified, among which are several minerals associated with acid rock drainage, including pyrite, jarosite, alunite, and goethite. Distributions of minerals such as calcite and chlorite indicate a relationship between acid-neutralizing assemblages and stream geochemistry within the watershed. Images denoting material distributions throughout the watershed have been orthorectified against digital terrain models to produce georeferenced image files suitable for inclusion in Geographic Information System databases. Results of this study are of use to land managers, stakeholders, and researchers interested in understanding a number of characteristics of the Animas River watershed.

  20. Design, development, testing and validation of a Photonics Virtual Laboratory for the study of LEDs

    NASA Astrophysics Data System (ADS)

    Naranjo, Francisco L.; Martínez, Guadalupe; Pérez, Ángel L.; Pardo, Pedro J.

    2014-07-01

    This work presents the design, development, testing and validation of a Photonic Virtual Laboratory, highlighting the study of LEDs. The study was conducted from a conceptual, experimental and didactic standpoint, using e-learning and m-learning platforms. Specifically, teaching tools that help ensure that our students perform significant learning have been developed. It has been brought together the scientific aspect, such as the study of LEDs, with techniques of generation and transfer of knowledge through the selection, hierarchization and structuring of information using concept maps. For the validation of the didactic materials developed, it has been used procedures with various assessment tools for the collection and processing of data, applied in the context of an experimental design. Additionally, it was performed a statistical analysis to determine the validity of the materials developed. The assessment has been designed to validate the contributions of the new materials developed over the traditional method of teaching, and to quantify the learning achieved by students, in order to draw conclusions that serve as a reference for its application in the teaching and learning processes, and comprehensively validate the work carried out.

  1. Comparison of results of fluconazole disk diffusion testing for Candida species with results from a central reference laboratory in the ARTEMIS global antifungal surveillance program.

    PubMed

    Pfaller, M A; Hazen, K C; Messer, S A; Boyken, L; Tendolkar, S; Hollis, R J; Diekema, D J

    2004-08-01

    The accuracy of antifungal susceptibility tests is important for accurate resistance surveillance and for the clinical management of patients with serious infections. Our main objective was to compare the results of fluconazole disk diffusion testing of Candida spp. performed by ARTEMIS participating centers with disk diffusion and MIC results obtained by the central reference laboratory. A total of 2,949 isolates of Candida spp. were tested by NCCLS disk diffusion and reference broth microdilution methods in the central reference laboratory. These results were compared to the results of disk diffusion testing performed in the 54 participating centers. All tests were performed and interpreted following NCCLS recommendations. Overall categorical agreement between participant disk diffusion test results and reference laboratory MIC results was 87.4%, with 0.2% very major errors (VME) and 3.3% major errors (ME). The categorical agreement between the disk diffusion test results obtained in the reference laboratory with the MIC test results was similar: 92.8%. Likewise, good agreement was observed between participant disk diffusion test results and reference laboratory disk diffusion test results: 90.4%, 0.4% VME, and 3.4% ME. The disk diffusion test was especially reliable in detecting those isolates of Candida spp. that were characterized as resistant by reference MIC testing. External quality assurance data obtained by surveillance programs such as the ARTEMIS Global Antifungal Surveillance Program ensure the generation of useful surveillance data and result in the continued improvement of antifungal susceptibility testing practices.

  2. Energy materials coordinating committee (EMaCC). Annual technical report, fiscal year 2005

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    2006-09-29

    The DOE Energy Materials Coordinating Committee (EMaCC) serves primarily to enhance coordination among the Department's materials programs and to further effective use of materials expertise within the Department. These functions are accomplished through the exchange of budgetary and planning information among program managers and through technical meetings/workshops on selected topics involving both DOE and major contractors. In addition, EMaCC assists in obtaining materials-related inputs for both intra- and interagency compilations. Topical subcommittees of the EMaCC are responsible for conducting seminars and otherwise facilitating information flow between DOE organizational units in materials areas of particular importance to the Department. The EMaCCmore » Terms of Reference were recently modified and developed into a Charter that was approved on June 5, 2003. As a result of this reorganization, the existing subcommittees were disbanded and new subcommittees are being formed. The FY 2004 budget summary for DOE Materials Activities is presented on page 8. The distribution of these funds between DOE laboratories, private industry, academia and other organizations is presented in tabular form on page 10. Following the budget summary is a set of detailed program descriptions for the FY 2004 DOE Materials activities. These descriptions are presented according to the organizational structure of the Department. A mission statement, a budget summary listing the project titles and FY 2004 funding, and detailed project summaries are presented for each Assistant Secretary office, the Office of Science, and the National Nuclear Security Administration. The project summaries also provide DOE, laboratory, academic and industrial contacts for each project, as appropriate.« less

  3. Energy materials coordinating committee (EMaCC). Annual technical report, fiscal year 2004

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2005-08-31

    The DOE Energy Materials Coordinating Committee (EMaCC) serves primarily to enhance coordination among the Department's materials programs and to further effective use of materials expertise within the Department. These functions are accomplished through the exchange of budgetary and planning information among program managers and through technical meetings/workshops on selected topics involving both DOE and major contractors. In addition, EMaCC assists in obtaining materials-related inputs for both intra- and interagency compilations. Topical subcommittees of the EMaCC are responsible for conducting seminars and otherwise facilitating information flow between DOE organizational units in materials areas of particular importance to the Department. The EMaCCmore » Terms of Reference were recently modified and developed into a Charter that was approved on June 5, 2003. As a result of this reorganization, the existing subcommittees were disbanded and new subcommittees are being formed. The FY 2004 budget summary for DOE Materials Activities is presented on page 8. The distribution of these funds between DOE laboratories, private industry, academia and other organizations is presented in tabular form on page 10. Following the budget summary is a set of detailed program descriptions for the FY 2004 DOE Materials activities. These descriptions are presented according to the organizational structure of the Department. A mission statement, a budget summary listing the project titles and FY 2004 funding, and detailed project summaries are presented for each Assistant Secretary office, the Office of Science, and the National Nuclear Security Administration. The project summaries also provide DOE, laboratory, academic and industrial contacts for each project, as appropriate.« less

  4. Leaching from solid waste incineration ashes used in cement-treated base layers for pavements.

    PubMed

    Cai, Z; Bager, Dirch H; Christensen, T H

    2004-01-01

    Waste incineration bottom ash and treated flue gas cleaning products mixed with 2.5% of cement (50 kg/m3) were tested in the laboratory in terms of compressive strength and tank leaching tests over a 64-day period. Although the material displayed lower mechanical strength than a reference concrete, the strength still was sufficient for use as a base layer for roads. The metal content in the incineration-residue-based specimens was up to 100 times higher than in the reference concrete, suggesting that the mixed waste incineration residue should be used only for dedicated purposes. The leaching of Cl and Na was increased by a factor of 20-100 from the incineration-residue-based specimens as compared to the reference, while the leaching of K, Ca and SO4 was increased by a factor of 2-10. The leaching of heavy metals was also higher from the incineration-residue-based specimens than from the reference with respect to Cu (50 times), Cd, Pb and Zn (5 times), but not with respect to Cr and Ni. The leaching curves did only allow for a closer evaluation of the leaching process in a few cases. The physical retention of the constituents seemed to be the same in the reference as in the incineration-residue-based specimens. Heavy metal leaching was limited by enhanced chemical retention in the incineration-residue-specimens as compared to the reference. Since no quality criteria in terms of leaching from a monolithic material are currently available, the leaching issue must be evaluated case by case.

  5. Reference values of thirty-one frequently used laboratory markers for 75-year-old males and females

    PubMed Central

    Ryden, Ingvar; Lind, Lars

    2012-01-01

    Background We have previously reported reference values for common clinical chemistry tests in healthy 70-year-old males and females. We have now repeated this study 5 years later to establish reference values also at the age of 75. It is important to have adequate reference values for elderly patients as biological markers may change over time, and adequate reference values are essential for correct clinical decisions. Methods We have investigated 31 frequently used laboratory markers in 75-year-old males (n = 354) and females (n = 373) without diabetes. The 2.5 and 97.5 percentiles for these markers were calculated according to the recommendations of the International Federation of Clinical Chemistry. Results Reference values are reported for 75-year-old males and females for 31 frequently used laboratory markers. Conclusion There were minor differences between reference intervals calculated with and without individuals with cardiovascular diseases. Several of the reference intervals differed from Scandinavian reference intervals based on younger individuals (Nordic Reference Interval Project). PMID:22300333

  6. Reference earth orbital research and applications investigations (blue book). Volume 6: Materials sciences and manufacturing

    NASA Technical Reports Server (NTRS)

    1971-01-01

    The development of commercial manufacturing and research activities in space is discussed. The capability is to be installed in space stations in order to exploit the extended free fall which makes many novel manipulations of materials possible and alters the behavior of certain chemical and physical processes. The broad objectives are: (1) to develop technical basis required for commercial use of manned space facilities, (2) to provide indirect economic benefits by exploiting advantages of space laboratory facilities to solve critical experimental problems, and (3) to initiate manufacturing operations in space by private enterprise for commercial purposes and by agencies of the Government for public purposes.

  7. The evidence base for 'own label' resin-based dental restoratives.

    PubMed

    Burke, F J Trevor

    2013-01-01

    There is anecdotal evidence that sales of 'own-label' (OL) or 'private label' dental products is increasing, as dentists become more cost conscious in times of economic downturn. However, the purchase of such (less expensive) products could be a false economy if their performance falls below accepted standards. So, while the examination of a resin-based product under research conditions alone may not guarantee success, it could be considered that a material which has been subjected to testing under research conditions will demonstrate its effectiveness under laboratory conditions or reveal its shortcomings; either of these being better than the material not being examined in any way. It was therefore considered appropriate to determine the materials on which research was carried out, with particular reference to OL brands. To determine whether there is a research base behind OL resin-based restorative dental materials.

  8. HPLC-APCI-MS analysis of triacylglycerols (TAGs) in historical pharmaceutical ointments from the eighteenth century.

    PubMed

    Saliu, Francesco; Modugno, Francesca; Orlandi, Marco; Colombini, Maria Perla

    2011-10-01

    The lipid fractions of residues from historical pharmaceutical ointments were analysed by reversed-phase liquid chromatography coupled with atmospheric pressure chemical ionization and mass spectrometer detection. The residues were contained in a series of historical apothecary jars, dating from the eighteenth century and conserved at the "Aboca Museum" in Sansepolcro (Arezzo, Italy) and at the pharmacy of the "Real Cartuja de Valldemossa" in Palma de Majorca (Spain). The analytical protocol was set up using a comparative study based on the evaluation of triacylglycerol (TAG) compositions in raw natural lipid materials and in laboratory-reproduced ointments. These ointments were prepared following pharmaceutical recipes reported in historical treatises and used as reference materials. The reference materials were also subjected to stress treatments in order to evaluate the modification occurring in the TAG profiles as an effect of ageing. TAGs were successfully detected in the reproduced formulations even in mixtures of up to ten ingredients and after harsh degradative treatments, and also in real historical samples. No particular interferences were detected from other non-lipid ingredients of the formulations. The TAG compositions detected in the historical ointments indicated a predominant use of olive oil and pig adipose material as lipid ingredients. The detection of a high level of tristearine and myristyl-palmitoyl-stearyl glycerol in two of the samples suggested the presence of a fatty material of a different origin (maybe a ruminant). On the basis of the positional isomer ratio, sn-PPO/sn-POP, it was possible to hypothesize an exclusive use of pig fat in one sample. We also evaluated the application of principal component analysis of TAG profiles as an approach for the multivariate statistical comparison of the reference and historical ointments.

  9. Production and certification of NIST Standard Reference Material 2372 Human DNA Quantitation Standard.

    PubMed

    Kline, Margaret C; Duewer, David L; Travis, John C; Smith, Melody V; Redman, Janette W; Vallone, Peter M; Decker, Amy E; Butler, John M

    2009-06-01

    Modern highly multiplexed short tandem repeat (STR) assays used by the forensic human-identity community require tight control of the initial amount of sample DNA amplified in the polymerase chain reaction (PCR) process. This, in turn, requires the ability to reproducibly measure the concentration of human DNA, [DNA], in a sample extract. Quantitative PCR (qPCR) techniques can determine the number of intact stretches of DNA of specified nucleotide sequence in an extremely small sample; however, these assays must be calibrated with DNA extracts of well-characterized and stable composition. By 2004, studies coordinated by or reported to the National Institute of Standards and Technology (NIST) indicated that a well-characterized, stable human DNA quantitation certified reference material (CRM) could help the forensic community reduce within- and among-laboratory quantitation variability. To ensure that the stability of such a quantitation standard can be monitored and that, if and when required, equivalent replacement materials can be prepared, a measurement of some stable quantity directly related to [DNA] is required. Using a long-established conventional relationship linking optical density (properly designated as decadic attenuance) at 260 nm with [DNA] in aqueous solution, NIST Standard Reference Material (SRM) 2372 Human DNA Quantitation Standard was issued in October 2007. This SRM consists of three quite different DNA extracts: a single-source male, a multiple-source female, and a mixture of male and female sources. All three SRM components have very similar optical densities, and thus very similar conventional [DNA]. The materials perform very similarly in several widely used gender-neutral assays, demonstrating that the combination of appropriate preparation methods and metrologically sound spectrophotometric measurements enables the preparation and certification of quantitation [DNA] standards that are both maintainable and of practical utility.

  10. Results of the U. S. Geological Survey's analytical evaluation program for standard reference samples distributed in April 2001

    USGS Publications Warehouse

    Woodworth, M.T.; Connor, B.F.

    2001-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-165 (trace constituents), M-158 (major constituents), N-69 (nutrient constituents), N-70 (nutrient constituents), P-36 (low ionic-strength constituents), and Hg-32 (mercury) -- that were distributed in April 2001 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 73 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  11. Results of the U. S. Geological Survey's Analytical Evaluation Program for Standard Reference Samples Distributed in March 2002

    USGS Publications Warehouse

    Woodworth, M.T.; Conner, B.F.

    2002-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T- 169 (trace constituents), M- 162 (major constituents), N-73 (nutrient constituents), N-74 (nutrient constituents), P-38 (low ionic-strength constituents), and Hg-34 (mercury) -- that were distributed in March 2002 to laboratories enrolled in the U.S. Geological Survey sponsored intedaboratory testing program. Analytical data received from 93 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  12. Results of the U.S. Geological Survey's analytical evaluation program for standard reference samples distributed in September 2002

    USGS Publications Warehouse

    Woodworth, Mark T.; Connor, Brooke F.

    2003-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-171 (trace constituents), M-164 (major constituents), N-75 (nutrient constituents), N-76 (nutrient constituents), P-39 (low ionic-strength constituents), and Hg-35 (mercury) -- that were distributed in September 2002 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 102 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  13. Results of the U.S. Geological Survey's analytical evaluation program for standard reference samples distributed in September 2001

    USGS Publications Warehouse

    Woodworth, Mark T.; Connor, Brooke F.

    2002-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-167 (trace constituents), M-160 (major constituents), N-71 (nutrient constituents), N-72 (nutrient constituents), P-37 (low ionic-strength constituents), and Hg-33 (mercury) -- that were distributed in September 2001 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 98 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  14. Results of the U.S. Geological Survey's Analytical Evaluation Program for Standard Reference Samples Distributed in March 2000

    USGS Publications Warehouse

    Farrar, Jerry W.; Copen, Ashley M.

    2000-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-161 (trace constituents), M-154 (major constituents), N-65 (nutrient constituents), N-66 nutrient constituents), P-34 (low ionic strength constituents), and Hg-30 (mercury) -- that were distributed in March 2000 to 144 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 132 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  15. Results of the U.S. Geological Survey's analytical evaluation program for standard reference samples distributed in October 1999

    USGS Publications Warehouse

    Farrar, T.W.

    2000-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-159 (trace constituents), M-152 (major constituents), N-63 (nutrient constituents), N-64 (nutrient constituents), P-33 (low ionic strength constituents), and Hg-29 (mercury) -- that were distributed in October 1999 to 149 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 131 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  16. Results of the U.S. Geological Survey's analytical evaluation program for standard reference samples distributed in March 2003

    USGS Publications Warehouse

    Woodworth, Mark T.; Connor, Brooke F.

    2003-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-173 (trace constituents), M-166 (major constituents), N-77 (nutrient constituents), N-78 (nutrient constituents), P-40 (low ionic-strength constituents), and Hg-36 (mercury) -- that were distributed in March 2003 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 110 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  17. Results of the U. S. Geological Survey's analytical evaluation program for standard reference samples distributed in October 2000

    USGS Publications Warehouse

    Connor, B.F.; Currier, J.P.; Woodworth, M.T.

    2001-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-163 (trace constituents), M-156 (major constituents), N-67 (nutrient constituents), N-68 (nutrient constituents), P-35 (low ionic strength constituents), and Hg-31 (mercury) -- that were distributed in October 2000 to 126 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 122 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  18. Web-Based Virtual Laboratory for Food Analysis Course

    NASA Astrophysics Data System (ADS)

    Handayani, M. N.; Khoerunnisa, I.; Sugiarti, Y.

    2018-02-01

    Implementation of learning on food analysis course in Program Study of Agro-industrial Technology Education faced problems. These problems include the availability of space and tools in the laboratory that is not comparable with the number of students also lack of interactive learning tools. On the other hand, the information technology literacy of students is quite high as well the internet network is quite easily accessible on campus. This is a challenge as well as opportunities in the development of learning media that can help optimize learning in the laboratory. This study aims to develop web-based virtual laboratory as one of the alternative learning media in food analysis course. This research is R & D (research and development) which refers to Borg & Gall model. The results showed that assessment’s expert of web-based virtual labs developed, in terms of software engineering aspects; visual communication; material relevance; usefulness and language used, is feasible as learning media. The results of the scaled test and wide-scale test show that students strongly agree with the development of web based virtual laboratory. The response of student to this virtual laboratory was positive. Suggestions from students provided further opportunities for improvement web based virtual laboratory and should be considered for further research.

  19. BiliChek transcutaneous bilirubin meter overestimates serum bilirubin as measured by the Doumas reference method.

    PubMed

    Karon, Brad S; Wickremasinghe, Andrea C; Lo, Stanley F; Saenger, Amy K; Cook, Walter J

    2010-08-01

    To determine the relationship between BiliChek TcB (Respironics, Marietta GA) and Doumas reference serum or plasma total bilirubin (TSB). Pooled samples with values assigned by the Doumas reference method were used to establish the relationship between a local laboratory and reference Doumas TSB. We then established the relationship between TcB and TSB in the 3 months before and after reassignment of calibrator setpoints undertaken to match the local laboratory to Doumas reference bilirubin values. Before calibrator setpoint reassignment TSB as measured in our laboratory overestimated Doumas reference bilirubin. After calibrator adjustment laboratory TSB was within 1.7-6.8 micromol/L (0.1-0.4 mg/dL) of Doumas reference values. Mean bias between BiliChek TcB and TSB was 42.8+/-22.2 micromol/L (2.5+/-1.3mg/dL) (n=94) before and 49.6+/-22.2 micromol/L (2.9+/-1.3mg/dL) (n=115) after calibration adjustment. BiliChek TcB significantly overestimates TSB as measured by the Doumas reference method. 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  20. A comparison of the BAX system method to the U.S. Food and Drug Administration's Bacteriological Analytical Manual and International Organization for Standardization reference methods for the detection of Salmonella in a variety of soy ingredients.

    PubMed

    Belete, Tamrat; Crowley, Erin; Bird, Patrick; Gensic, Joseph; Wallace, F Morgan

    2014-10-01

    The performances of two DuPont BAX System PCR assays for detecting Salmonella on a variety of low-moisture soy ingredients were evaluated against the U. S. Food and Drug Administration's Bacteriological Analytical Manual (FDA BAM) method or the International Organization for Standardization (ISO) 6579 reference method. These evaluations were conducted as a single laboratory validation at an ISO 17025 accredited third-party laboratory. Validations were conducted on five soy ingredients: isolated soy protein (ISP), soy fiber, fluid soy lecithin, deoiled soy lecithin, and soy nuggets, using a paired-study design. The ISP was analyzed as both 25- and 375-g composite test portions, whereas all other sample matrices were analyzed as 375-g composite test portions. To evaluate 25-g test portions of ISP, the test material was inoculated using Salmonella enterica subsp. enterica serovar Mbandaka (Q Laboratories isolate 11031.1). Salmonella enterica subsp. enterica serovar Tennessee (Q Laboratories isolate 11031.3) was used for all other trials. For each trial of the method comparison, 25 samples were analyzed for each matrix: 5 uninoculated controls and 20 samples inoculated at low levels (0.2 to 2 CFU per test portion) that were targeted to achieve fractionally positive results (25 to 75%). Using McNemar's chi-square analysis, no significant difference at P ≥ 0.05 (χ(2) ≤ 3.84) was observed between the number of positives obtained by the BAX System and the reference methods for all five test matrices evaluated. These studies indicate that the BAX System PCR assays, in combination with the single buffered peptone water primary enrichment and subsequent brain heart infusion regrowth step, demonstrate equivalent sensitivity and robustness compared with the FDA BAM and ISO reference methods for both 25- and 375-g composite samples. Moreover, there was no observed reduction of sensitivity in the larger 375-g composite samples for all five matrices.

  1. Collaborative study for establishment of the European Pharmacopoeia BRP batch 1 for diphtheria toxin.

    PubMed

    Sesardic, D; Prior, C; Daas, A; Buchheit, K H

    2003-07-01

    A stable liquid candidate Biological Reference Preparation (BRP) for diphtheria toxin was prepared in peptone buffer (nominal content of diphtheria toxin: 1 Lf/ml, 0.4 micro g/ml), filled in ampoules (filling volume: 1 ml) and characterised in a collaborative study. The toxin is to be used in the test "Absence of toxin and irreversibility of toxoid" as described in the current European Pharmacopoeia (Ph. Eur.) monograph Diphtheria Vaccine (Adsorbed) (2002:0443). Eleven laboratories assessed the specific activity of the preparation by in vivo and in vitro assays. The material is assumed to have satisfactory stability with a calculated predicted loss of activity of <1% per year at 4-8 degrees C. From the collaborative study, the specific activity was calculated as 77.6 (45-113) LD( 50)/ml (lethal challenge) and >75 000 Lr/Lf (intradermal challenge). The candidate BRP was successfully used in nine laboratories and confirmed suitable for use in the Vero cell test for "Absence of toxin and irreversibility of toxoid" as described in the Ph. Eur. monograph 2002:0443; i.e., concentrations of 5 x 10( -5) Lf/ml and below caused cytotoxic effects in the Vero cell test. Due to its liquid nature, the stability of the material will be monitored at regular intervals and preparation of a stable freeze-dried formulation will be considered for long-term use. Additional studies will be performed to confirm suitability of this BRP for other applications. The candidate BRP was adopted as the Ph. Eur. reference material for Diphtheria Toxin Batch 1 by the Ph. Eur. Commission at its session in March 2003.

  2. Application of two low-cost adsorption media for removal of toxic metals from contaminated water.

    PubMed

    Somerville, R; Norrström, A C

    2009-01-01

    Since the operational costs of commonly used materials for adsorption of toxic metals can be substantial, natural material may be of great interest for treatment applications. Two types of natural material that have shown particular promise are seaweed and seafood waste. In this study, adsorption capacity of Brown seaweed and shrimp shells were compared with a strong acid cation exchange resin (CER). A case study site was used as a reference point and column experiments were designed in a similar manner although at different scale. Each media reduced concentrations of the target metals to levels below defined reference values. If the alternative adsorption media perform as well in the field as the laboratory, the results suggest that the media tested would completely remove the toxic metals in groundwater and runoff water. Seaweed and shrimp shells had stronger affinities for Pb and Cu than CER. However, CER was superior in affinity for Zn, the most weakly bound metal. Moreover, the results showed that Ca in the solution reduced the adsorption capacity of the other metals. This illustrates the limitations of applying the behaviour of the batch studies with single metal solutions to a multi-component system with competitive adsorption.

  3. Preparation of candidate reference materials for the determination of phosphorus containing flame retardants in styrene-based polymers.

    PubMed

    Roth, Thomas; Urpi Bertran, Raquel; Latza, Andreas; Andörfer-Lang, Katrin; Hügelschäffer, Claudia; Pöhlein, Manfred; Puchta, Ralph; Placht, Christian; Maid, Harald; Bauer, Walter; van Eldik, Rudi

    2015-04-01

    Candidate reference materials (RM) for the analysis of phosphorus-based flame retardants in styrene-based polymers were prepared using a self-made mini-extruder. Due to legal requirements of the current restriction for the use of certain hazardous substances in electrical and electronic equipment, focus now is placed on phosphorus-based flame retardants instead of the brominated kind. Newly developed analytical methods for the first-mentioned substances also require RMs similar to industrial samples for validation and verification purposes. Hence, the prepared candidate RMs contained resorcinol-bis-(diphenyl phosphate), bisphenol A bis(diphenyl phosphate), triphenyl phosphate and triphenyl phosphine oxide as phosphorus-based flame retardants. Blends of polycarbonate and acrylonitrile-co-butadiene-co-styrene as well as blends of high-impact polystyrene and polyphenylene oxide were chosen as carrier polymers. Homogeneity and thermal stability of the candidate RMs were investigated. Results showed that the candidate RMs were comparable to the available industrial materials. Measurements by ICP/OES, FTIR and NMR confirmed the expected concentrations of the flame retardants and proved that analyte loss and degradation, respectively, was below the uncertainty of measurement during the extrusion process. Thus, the candidate RMs were found to be suitable for laboratory use.

  4. Microscopic diagnosis of sodium acetate-acetic acid-formalin-fixed stool samples for helminths and intestinal protozoa: a comparison among European reference laboratories.

    PubMed

    Utzinger, J; Botero-Kleiven, S; Castelli, F; Chiodini, P L; Edwards, H; Köhler, N; Gulletta, M; Lebbad, M; Manser, M; Matthys, B; N'Goran, E K; Tannich, E; Vounatsou, P; Marti, H

    2010-03-01

    The present study aimed to compare the diagnostic performance of different European reference laboratories in diagnosing helminths and intestinal protozoa, using an ether-concentration method applied to sodium acetate-acetic acid-formalin (SAF)-preserved faecal samples. In total, 102 stool specimens were analysed during a cross-sectional parasitological survey in urban farming communities in Côte d'Ivoire. Five SAF-preserved faecal samples were prepared from each specimen and forwarded to the participating reference laboratories, processed and examined under a microscope adhering to a standard operating procedure (SOP). Schistosoma mansoni (cumulative prevalence: 51.0%) and hookworm (cumulative prevalence: 39.2%) were the predominant helminths. There was excellent agreement (kappa > 0.8; p < 0.001) among the reference laboratories for the diagnosis of S. mansoni, hookworm, Trichuris trichiura and Ascaris lumbricoides. Moderate agreement (kappa = 0.54) was found for Hymenolepis nana, and lesser agreement was observed for other, less prevalent helminths. The predominant intestinal protozoa were Entamoeba coli (median prevalence: 67.6%), Blastocystis hominis (median prevalence: 55.9%) and Entamoeba histolytica/Entamoeba dispar (median prevalence: 47.1%). Substantial agreement among reference laboratories was found for E. coli (kappa = 0.69), but only fair or moderate agreement was found for other Entamoeba species, Giardia intestinalis and Chilomastix mesnili. There was only poor agreement for B. hominis, Isospora belli and Trichomonas intestinalis. In conclusion, although common helminths were reliably diagnosed by European reference laboratories, there was only moderate agreement between centres for pathogenic intestinal protozoa. Continued external quality assessment and the establishment of a formal network of reference laboratories is necessary to further enhance both accuracy and uniformity in parasite diagnosis.

  5. Materials Characterization Laboratory | Energy Systems Integration Facility

    Science.gov Websites

    | NREL Materials Characterization Laboratory Materials Characterization Laboratory The Energy Systems Integration Facility's Materials Characterization Laboratory supports the physical and photo -electrochemical characterization of novel materials. Photo of an NREL researcher preparing samples for a gas

  6. Workshop on standards in biomass for energy and chemicals: proceedings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Milne, T.A.

    1984-11-01

    In the course of reviewing standards literature, visiting prominent laboratories and research groups, attending biomass meetings and corresponding widely, a whole set of standards needs was identified, the most prominent of which were: biomass standard reference materials, research materials and sample banks; special collections of microorganisms, clonal material, algae, etc.; standard methods of characterization of substrates and biomass fuels; standard tests and methods for the conversion and end-use of biomass; standard protocols for the description, harvesting, preparation, storage, and measurement of productivity of biomass materials in the energy context; glossaries of terms; development of special tests for assay of enzymaticmore » activity and related processes. There was also a recognition of the need for government, professional and industry support of concensus standards development and the dissemination of information on standards. Some 45 biomass researchers and managers met with key NBS staff to identify and prioritize standards needs. This was done through three working panels: the Panel on Standard Reference Materials (SRM's), Research Materials (RM's), and Sample Banks; the Panel on Production and Characterization; and the Panel on Tests and Methods for Conversion and End Use. This report gives a summary of the action items in standards development recommended unanimously by the workshop attendees. The proceedings of the workshop, and an appendix, contain an extensive written record of the findings of the workshop panelists and others regarding presently existing standards and standards issues and needs. Separate abstracts have been prepared for selected papers for inclusion in the Energy Database.« less

  7. Ultra-low level plutonium isotopes in the NIST SRM 4355A (Peruvian Soil-1).

    PubMed

    Inn, Kenneth G W; LaRosa, Jerome; Nour, Svetlana; Brooks, George; LaMont, Steve; Steiner, Rob; Williams, Ross; Patton, Brad; Bostick, Debbie; Eiden, Gregory; Petersen, Steve; Douglas, Matthew; Beals, Donna; Cadieux, James; Hall, Greg; Goldberg, Steve; Vogt, Stephan

    2009-05-01

    For more than 20 years, countries and their agencies which monitor radionuclide discharge sites and storage facilities have relied on the National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 4355 Peruvian Soil. Its low fallout contamination makes it an ideal soil blank for measurements associated with terrestrial-pathway-to-man studies. Presently, SRM 4355 is out of stock, and a new batch of the Peruvian soil is currently under development as future NIST SRM 4355A. Both environmental radioanalytical laboratories and mass spectrometry communities will benefit from the use of this SRM. The former must assess their laboratory procedural contamination and measurement detection limits by measurement of blank sample material. The Peruvian Soil is so low in anthropogenic radionuclide content that it is a suitable virtual blank. On the other hand, mass spectrometric laboratories have high sensitivity instruments that are capable of quantitative isotopic measurements at low plutonium levels in the SRM 4355 (first Peruvian Soil SRM) that provided the mass spectrometric community with the calibration, quality control, and testing material needed for methods development and legal defensibility. The quantification of the ultra-low plutonium content in the SRM 4355A was a considerable challenge for the mass spectrometric laboratories. Careful blank control and correction, isobaric interferences, instrument stability, peak assessment, and detection assessment were necessary. Furthermore, a systematic statistical evaluation of the measurement results and considerable discussions with the mass spectroscopy metrologists were needed to derive the certified values and uncertainties. The one sided upper limit of the 95% tolerance with 95% confidence for the massic (239)Pu content in SRM 4355A is estimated to be 54,000 atoms/g.

  8. Thermal Storage Materials Laboratory | Energy Systems Integration Facility

    Science.gov Websites

    | NREL Materials Laboratory Thermal Storage Materials Laboratory In the Energy Systems Integration Facility's Thermal Storage Materials Laboratory, researchers investigate materials that can be used as high-temperature heat transfer fluids or thermal energy storage media in concentrating solar

  9. Sharpening the U-Th Chronometer: Progress and Outlook

    NASA Astrophysics Data System (ADS)

    McLean, N. M.; Condon, D. J.; Henderson, G. M.; Richards, D. A.; Noble, S.; Mason, A.

    2013-12-01

    Uranium is incorporated into a variety of natural materials when they form, including carbonates like speleothems and corals. The two most abundant naturally occurring uranium isotopes, 238U and 235U, decay to 206Pb and 207Pb over long timescales with half-lives of 4.5 and 0.7 billion years respectively, but transition through several intermediate daughter isotopes with shorter half-lives first. Fractionation between these daughter isotopes, including 234U, 230Th, and 231Pa, and their parent isotopes, followed by their time-dependent return to secular equilibrium over the course of up to ~800 kyr, forms the basis for U-series geochronology, and allows speleothems and corals to be precisely dated. These carbonates often additionally incorporate chemical and isotopic signatures (e.g., trace elements, δ18O and δ13C) from the environment in which they form, and thus are some of the best dated paleoclimate archives, offering clues about past and future conditions for life on Earth. Over the past decade, the analytical precision of U-series isotope measurements has improved dramatically, largely due to the steadily increasing sensitivity of multiple-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). Analytical uncertainties in U-Th dates now approach or are better than 0.1% (2σ), for instance ×100 years for a speleothem or coral that is 130 kyr old (Cheng et al., 2013). However, the accuracy of U-series dates also depends on the accuracy of tracer calibrations, reference solutions and data reduction protocols, which has not kept pace in many laboratories. This means that dates measured in different labs, while impressively precise, may not be directly comparable. To address issues of inter-laboratory bias and improve the accuracy and inter-comparability of U-Th dates, we have instigated work in three related directions. First, we report on the mixing of three synthetic U-Th age solutions, created by combining high-purity mono-isotopic solutions to mimic the isotopic composition of commonly analyzed materials. These age solutions will form the basis for an inter-laboratory comparison and serve as international reference materials for assessing long-term reproducibility. Second is the creation of several U-Th gravimetric solutions, which can be used to calibrate the mixed 229Th-236U×233U tracers used in the community without having to rely on materials assumed to be in secular equilibrium. Tracers calibrated against these solutions, and therefore U-Th dates measured with these tracers, will be fully metrologically traceable. Finally, we report progress on and important considerations in developing data reduction and uncertainty propagation protocols for calculating U-Th dates and constructing and interpreting U-Th age models. Reference: Cheng et al. (2013) EPSL 371-372, 82-91

  10. Applications of New Synthetic Uranium Reference Materials for Research in Geochemistry

    NASA Astrophysics Data System (ADS)

    Richter, Stephan; Alonso, Adolfo; Aregbe, Yetunde; Eykens, Roger; Jacobsson, Ulf; Kuehn, Heinz; Verbruggen, Andre; Weyer, Stefan

    2010-05-01

    For many applications in geochemistry research isotope ratio measurements play a significant role. In geochronology isotope abundances of uranium and its daughter products thorium and lead are being used to determine the age and history of various samples of geological interest. For measuring the isotopic compositions of these elements by mass spectrometry, suitable isotope reference materials are needed to validate measurement procedures and to calibrate multi-collector and ion counting detector systems. IRMM is a recognized provider for nuclear isotope reference materials to the nuclear industry and nuclear safeguards authorities, which are also being applied widely for geochemical applications. Firstly, the double spike IRMM-3636 with a 233U/236U ratio of 1:1 was prepared which allows internal mass fractionation correction for high precision 235U/238U ratio measurements. The 234U abundance of this double spike material is low enough to allow an accurate and precise correction of 234U/238U ratios, even for measurements of close to equilibrium uranium samples. The double spike IRMM-3636 is offered in 3 concentrations: 1mg/g, 0.1mg/g and 0.005mg/g. Secondly, the 236U single spike IRMM-3660 was prepared and is offered in 3 concentrations: 1mg/g, 0.1mg/g and 0.01mg/g. Thirdly, a "Quad"-isotope reference material, IRMM-3101, has been prepared which is characterized by 233U/235U/236U/238U=1/1/1/1. This material is useful for checking Faraday cup efficiencies and inter-calibration of MIC (multiple ion counting) detectors. The quad-IRM is offered in 3 concentrations: 1mg/g, 0.1mg/g and 0.01mg/g. As one example for the significant influence of synthetic reference materials for geochemical research, the IRMM-074 series of gravimetrically prepared uranium mixtures for linearity testing of secondary electron multipliers (SEMs) has been applied for the redetermination of the secular equilibrium 234U/238U value and the 234U half-life by Cheng et al (2009). Due to the use of IRMM-074, results with smaller uncertainties were obtained, which are shifted by about 0.04% compared to the commonly used values published earlier by Cheng et al. in 2000. This has a significant impact for U isotope measurements in geochemistry. As another example for a geochemical application, by using the new double spike IRMM-3636, the 235U/238U ratios for several commonly used natural U standard materials from NIST/NBL and IRMM, such as e.g. NBS960 (=NBL CRM-112a), NBS950a,b and IRMM-184, have been re-measured at IRMM and other laboratories with improved precision and accuracy. The (preliminary) new result of 137.839(24) for the 238U/235U ratio of NBL CRM-112a is deviating by -0.030% from the well-known and widely used old consensus value of 137.88. For this old consensus value no uncertainty has ever been assigned, but it is outside the uncertainty limits of the new measurement result. The new result is based on measurements made at several laboratories worldwide, such as University of Frankfurt (Germany), National Taiwan University, NERC (University of Nottingham, UK), UNM (University of Minnesota, US), Thermo Fisher Scientific, LLNL (Lawrence Livermore National Laboratory, US.DOE), SAL/IAEA and IRMM. The (preliminary) new result of 137.839(24) can therefore be proposed as a new consensus value for the 238U/235U ratio of NBL CRM-112a. In contrast to the older consensus value, this new result is traceable to the common SI system of units and has an uncertainty assigned to it. For the close to natural standard IRMM-184, the re-measured 238U/235U ratio of 137.683(23) agrees quite well with the certified value of 137.697(41), the calculated difference is only -0.010(35)% which is insignificant. As a conclusion, the IRMM-3636 Double Spike has been successfully applied for measurements of important uranium isotopic standards like NBL CRM-112a and IRMM-184, with improved uncertainties at the level of 0.016% and traceability to the SI system.

  11. SENIORLAB: a prospective observational study investigating laboratory parameters and their reference intervals in the elderly.

    PubMed

    Risch, Martin; Nydegger, Urs; Risch, Lorenz

    2017-01-01

    In clinical practice, laboratory results are often important for making diagnostic, therapeutic, and prognostic decisions. Interpreting individual results relies on accurate reference intervals and decision limits. Despite the considerable amount of resources in clinical medicine spent on elderly patients, accurate reference intervals for the elderly are rarely available. The SENIORLAB study set out to determine reference intervals in the elderly by investigating a large variety of laboratory parameters in clinical chemistry, hematology, and immunology. The SENIORLAB study is an observational, prospective cohort study. Subjectively healthy residents of Switzerland aged 60 years and older were included for baseline examination (n = 1467), where anthropometric measurements were taken, medical history was reviewed, and a fasting blood sample was drawn under optimal preanalytical conditions. More than 110 laboratory parameters were measured, and a biobank was set up. The study participants are followed up every 3 to 5 years for quality of life, morbidity, and mortality. The primary aim is to evaluate different laboratory parameters at age-related reference intervals. The secondary aims of this study include the following: identify associations between different parameters, identify diagnostic characteristics to diagnose different circumstances, identify the prevalence of occult disease in subjectively healthy individuals, and identify the prognostic factors for the investigated outcomes, including mortality. To obtain better grounds to justify clinical decisions, specific reference intervals for laboratory parameters of the elderly are needed. Reference intervals are obtained from healthy individuals. A major obstacle when obtaining reference intervals in the elderly is the definition of health in seniors because individuals without any medical condition and any medication are rare in older adulthood. Reference intervals obtained from such individuals cannot be considered representative for seniors in a status of age-specific normal health. In addition to the established methods for determining reference intervals, this longitudinal study utilizes a unique approach, in that survival and long-term well-being are taken as indicators of health in seniors. This approach is expected to provide robust and representative reference intervals that are obtained from an adequate reference population and not a collective of highly selected individuals. The present study was registered under International Standard Randomized Controlled Trial Number registry: ISRCTN53778569.

  12. First proficiency testing to evaluate the ability of European Union National Reference Laboratories to detect staphylococcal enterotoxins in milk products.

    PubMed

    Hennekinne, Jacques-Antoine; Gohier, Martine; Maire, Tiphaine; Lapeyre, Christiane; Lombard, Bertrand; Dragacci, Sylviane

    2003-01-01

    The European Commission has designed a network of European Union-National Reference Laboratories (EU-NRLs), coordinated by a Community Reference Laboratory (CRL), for control of hygiene of milk and milk products (Council Directive 92/46/ECC). As a common contaminant of milk and milk products such as cheese, staphylococcal enterotoxins are often involved in human outbreaks and should be monitored regularly. The main tasks of the EU-CRLs were to select and transfer to the EU-NRLs a reference method for detection of enterotoxins, and to set up proficiency testing to evaluate the competency of the European laboratory network. The first interlaboratory exercise was performed on samples of freeze-dried cheese inoculated with 2 levels of staphylococcal enterotoxins (0.1 and 0.25 ng/g) and on an uninoculated control. These levels were chosen considering the EU regulation for staphylococcal enterotoxins in milk and milk products and the limit of detection of the enzyme-linked immunosorbent assay test recommended in the reference method. The trial was conducted according to the recommendations of ISO Guide 43. Results produced by laboratories were compiled and compared through statistical analysis. Except for data from 2 laboratories for the uninoculated control and cheese inoculated at 0.1 ng/g, all laboratories produced satisfactory results, showing the ability of the EU-NRL network to monitor the enterotoxin contaminant.

  13. Proton irradiation on materials

    NASA Technical Reports Server (NTRS)

    Chang, C. Ken

    1993-01-01

    A computer code is developed by utilizing a radiation transport code developed at NASA Langley Research Center to study the proton radiation effects on materials which have potential application in NASA's future space missions. The code covers the proton energy from 0.01 Mev to 100 Gev and is sufficient for energetic protons encountered in both low earth and geosynchronous orbits. With some modification, the code can be extended for particles heavier than proton as the radiation source. The code is capable of calculating the range, stopping power, exit energy, energy deposition coefficients, dose, and cumulative dose along the path of the proton in a target material. The target material can be any combination of the elements with atomic number ranging from 1 to 92, or any compound with known chemical composition. The generated cross section for a material is stored and is reused in future to save computer time. This information can be utilized to calculate the proton dose a material would receive in an orbit when the radiation environment is known. It can also be used to determine, in the laboratory, the parameters such as beam current of proton and irradiation time to attain the desired dosage for accelerated ground testing of any material. It is hoped that the present work be extended to include polymeric and composite materials which are prime candidates for use as coating, electronic components, and structure building. It is also desirable to determine, for ground testing these materials, the laboratory parameters in order to simulate the dose they would receive in space environments. A sample print-out for water subject to 1.5 Mev proton is included as a reference.

  14. External Quality Assessment Scheme for reference laboratories - review of 8 years' experience.

    PubMed

    Kessler, Anja; Siekmann, Lothar; Weykamp, Cas; Geilenkeuser, Wolf Jochen; Dreazen, Orna; Middle, Jonathan; Schumann, Gerhard

    2013-05-01

    We describe an External Quality Assessment Scheme (EQAS) intended for reference (calibration) laboratories in laboratory medicine and supervised by the Scientific Division of the International Federation of Clinical Chemistry and Laboratory Medicine and the responsible Committee on Traceability in Laboratory Medicine. The official EQAS website, RELA (www.dgkl-rfb.de:81), is open to interested parties. Information on all requirements for participation and results of surveys are published annually. As an additional feature, the identity of every participant in relation to the respective results is disclosed. The results of various groups of measurands (metabolites and substrates, enzymes, electrolytes, glycated hemoglobins, proteins, hormones, thyroid hormones, therapeutic drugs) are discussed in detail. The RELA system supports reference measurement laboratories preparing for accreditation according to ISO 17025 and ISO 15195. Participation in a scheme such as RELA is one of the requirements for listing of the services of a calibration laboratory by the Joint Committee on Traceability in Laboratory Medicine.

  15. Final report on EURAMET.QM-K12: EURAMET key comparison on the determination of the mass fraction of creatinine in serum

    NASA Astrophysics Data System (ADS)

    Bell, David; Hopley, Chris; Ellison, Stephen L. R.; O'Connor, Gavin

    2013-01-01

    Creatinine is a well-known marker for the evaluation of kidney function. Its routine measurement is undertaken by many clinical laboratories and comparable results over distance and time are required for effective diagnosis. To address this need many National Measurement Institutes (or designated institutes) provide services in this area via the provision of higher order standards or reference measurements. The organic analysis working group of the consultative committee for amount of substance have conducted two previous key comparisons to assess the equivalence of institutes who provide such services. The purpose of this study was to enable institutes who missed the previous studies to demonstrate their capability for characterizing serum materials containing 1 µg/g to 100 µg/g of creatinine. The study material consisted of two lyophilized serum samples which were used in an external quality control proficiency testing scheme. No target values were available for these materials and all participants reported results within the one month timeframe given for analysis. Five institutes participated in the key study and a single institute submitted results for the parallel pilot study. All participants in the key study used isotope dilution with either gas or liquid chromatography coupled with mass spectrometry. The pilot study laboratory used a novel isotope dilution surface-enhanced Raman spectroscopy method. The comparison reference value for each material was set as the mean of all results submitted by those participating in the key study. The choice of the reference value estimator was constrained as it was deemed more appropriate to treat the data in a similar manner to CCQM-K12 if the relative degrees of equivalence were to be compared. This resulted in reference values of (54.27 ± 0.72) µg/g and (38.01 ± 0.42) µg/g for the two separate materials. The relative degrees of equivalence were calculated and these were compared with the relative degrees of equivalence of participants in CCQM-K12. The range of participants' results in EURAMET.QM-K12 for both levels (2% and 3% respectively for materials A and B) was greater than the 1% achieved in CCQM-K12. However, it was concluded that this study was suitable to support CMCs for creatinine in serum for 1 µg/g to 100 µg/g with uncertainties at the 1% to 1.5% level. This was found to be fit for purpose and consistent with the majority of CMCs currently approved. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. An automated and objective method for age partitioning of reference intervals based on continuous centile curves.

    PubMed

    Yang, Qian; Lew, Hwee Yeong; Peh, Raymond Hock Huat; Metz, Michael Patrick; Loh, Tze Ping

    2016-10-01

    Reference intervals are the most commonly used decision support tool when interpreting quantitative laboratory results. They may require partitioning to better describe subpopulations that display significantly different reference values. Partitioning by age is particularly important for the paediatric population since there are marked physiological changes associated with growth and maturation. However, most partitioning methods are either technically complex or require prior knowledge of the underlying physiology/biological variation of the population. There is growing interest in the use of continuous centile curves, which provides seamless laboratory reference values as a child grows, as an alternative to rigidly described fixed reference intervals. However, the mathematical functions that describe these curves can be complex and may not be easily implemented in laboratory information systems. Hence, the use of fixed reference intervals is expected to continue for a foreseeable time. We developed a method that objectively proposes optimised age partitions and reference intervals for quantitative laboratory data (http://research.sph.nus.edu.sg/pp/ppResult.aspx), based on the sum of gradient that best describes the underlying distribution of the continuous centile curves. It is hoped that this method may improve the selection of age intervals for partitioning, which is receiving increasing attention in paediatric laboratory medicine. Copyright © 2016 Royal College of Pathologists of Australasia. Published by Elsevier B.V. All rights reserved.

  17. Comparing results of X-ray diffraction, µ-Raman spectroscopy and neutron diffraction when identifying chemical phases in seized nuclear material, during a comparative nuclear forensics exercise

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rondahl, Stina Holmgren; Pointurier, Fabien; Ahlinder, Linnea

    This work presents the results for identification of chemical phases obtained by several laboratories as a part of an international nuclear forensic round-robin exercise. In this work powder X-ray diffraction (p-XRD) is regarded as the reference technique. Neutron diffraction produced a superior high-angle diffraction pattern relative to p-XRD. Requiring only small amounts of sample, µ-Raman spectroscopy was used for the first time in this context as a potentially complementary technique to p-XRD. The chemical phases were identified as pure UO 2 in two materials, and as a mixture of UO 2, U 3O 8 and an intermediate species U 3Omore » 7 in the third material.« less

  18. Comparing results of X-ray diffraction, µ-Raman spectroscopy and neutron diffraction when identifying chemical phases in seized nuclear material, during a comparative nuclear forensics exercise

    DOE PAGES

    Rondahl, Stina Holmgren; Pointurier, Fabien; Ahlinder, Linnea; ...

    2018-01-24

    This work presents the results for identification of chemical phases obtained by several laboratories as a part of an international nuclear forensic round-robin exercise. In this work powder X-ray diffraction (p-XRD) is regarded as the reference technique. Neutron diffraction produced a superior high-angle diffraction pattern relative to p-XRD. Requiring only small amounts of sample, µ-Raman spectroscopy was used for the first time in this context as a potentially complementary technique to p-XRD. The chemical phases were identified as pure UO 2 in two materials, and as a mixture of UO 2, U 3O 8 and an intermediate species U 3Omore » 7 in the third material.« less

  19. W-Band Transmission MeasurementS and X-Band Dielectric Properties Measurements for a Radome Material Sample

    NASA Technical Reports Server (NTRS)

    Cravey, Robin L.; Tiemsin, Pacita I.

    1997-01-01

    This paper describes measurements which were performed on a sample of radome material in the Electromagnetic Properties Measurements Laboratory (EPML). The purpose of the measurements described in this paper was to determine the one-way transmission loss through the flat panel of radome material for a frequency range of 84 to 94 GHz, for varying incidence angles. The panel, which was manufactured by Norton Performance Plastics Corporation, was provided to the EPML by TRW. The size of the panel is 40 in x 36 in x 0.422 in and consists of a foam material with one side coated with a smooth white coating (this side will be referred to as the front side). The dielectric properties of the foam material from the inside of the panel were also determined at X-band (8.2-12.4 GHz). The W-band free space measurements are presented first, followed by the X-band dielectric properties measurements.

  20. NOAA National Status and Trends Program Twelfth Round Intercomparison Exercise Results for Trace Metals in Marine Sediments and Biological Tissues. National Status and Trends Program for marine environmental quality: Technical memo

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willie, S.

    1998-11-01

    The report summarizes the results of the Twelfth Round Intercomparison for Trace Metals in Marine Sediments and Biological Tissues under the directive of the NOAA National Status and Trends Program. A total of forty-four participants were included in the exercise, including NOAA, USEPA, state, Austrailian, Canadian, Mexican and Argentinean laboratories. Two samples were sent by NRC to each participant, a marine sediment collected on the east coast of Canada and a freeze-dried mussel tissue. Laboratories were also asked to analyze two certified reference materials (CRMs) MESS-2 and CRM 2976. The elements to be determined were Al, Cr, Fe, Ni, Cu,more » Zn, As, Se, Ag, Cd, Sn, Hg, and Pb for both matrices, plus Be, Si, Mn, Sb, and Tl for the sediments. An accepted mean and confidence interval was calculated for each analyte in the two unknown samples, laboratory biases were identified and an overall rating of superior, good, fair or others were assigned to each laboratory.« less

  1. A study of 6S workplace improvement in Ergonomic Laboratory

    NASA Astrophysics Data System (ADS)

    Sari, AD; Suryoputro, MR; Rahmillah, FI

    2017-12-01

    This article discusses 6S implementation in Ergonomic Laboratory, Department of Industrial Engineering, Islamic University of Indonesia. This research is improvement project of 5S implementation in Ergonomic laboratory. Referring to the 5S implementation of the previous year, there have been improvements from environmental conditions or a more organized workplace however there is still a lack of safety aspects. There are several safeties problems such as equipment arrangement, potential hazards of room dividers that cause injury several times, placement of fire extinguisher, no evacuation path and assembly point in case of fire, as well as expired hydrant condition and lack of awareness of stakeholders related to safety. Therefore, this study aims to apply the 6S kaizen method to the Ergonomic laboratory to facilitate the work process, reduce waste, improve work safety and improve staff performance. Based on the score 6S assessment increased audit results by 32 points, before implementation is 75 point while after implementation is 107 point. This has implications for better use for mitigate people in laboratory area, save time when looking for tools and materials, safe workplace, as well as improving the culture and spirit of ‘6S’ on staff due to better and safetier working environment.

  2. Category 1 external quality assessment program for serum creatinine.

    PubMed

    González-Lao, Elisabet; Díaz-Garzón, Jorge; Corte, Zoraida; Ricós, Carmen; Perich, Carmen; Álvarez, Virtudes; Simón, Margarita; Minchinela, Joana; García-Lario, José Vicente; Boned, Beatriz; Biosca, Carmen; Cava, Fernando; Fernández-Fernández, Pilar; Fernández-Calle, Pilar

    2017-03-01

    The Commission of Analytical Quality and the Committee of External Quality Programs of Spanish Society of Laboratory Medicine (SEQC) in collaboration with the Dutch Foundation for the Quality organized the first national category 1 External Quality Assessment Programs (EQAP) pilot study. The aim is to evaluate the standardization of serum creatinine measurements in the Spanish laboratories through a category 1 external quality assurance program with commutable material and reference method assigned values. A total of 87 Spanish laboratories were involved in this program in 2015. Each day a sample control was measured by duplicate during 6 consecutive days. Percentage deviations and coefficients of variation obtained were compared with quality specifications derived from biological variation. A total of 1044 creatinine results were obtained. Laboratories were coded in 11 different method-traceability combinations. Only enzymatic methods get all results within the acceptability limits. To participate in a category 1 EQAP is a valuable tool to assess the standardization degree in our country; a big effort should be made to promote laboratories to change their procedures and to use enzymatic creatinine methods, in order to achieve a satisfactory standardization degree for this important analyte.

  3. Interlaboratory Comparison of Magnetic Thin Film Measurements.

    PubMed

    da Silva, F C S; Wang, C M; Pappas, D P

    2003-01-01

    A potential low magnetic moment standard reference material (SRM) was studied in an interlaboratory comparison. The mean and the standard deviation of the saturation moment m s, the remanent moment m r, and the intrinsic coercivity H c of nine samples were extracted from hysteresis-loop measurements. Samples were measured by thirteen laboratories using inductive-field loopers, vibrating-sample magnetometers, alternating-gradient force magnetometers, and superconducting quantum-interference-device magnetometers. NiFe films on Si substrates had saturation moment measurements reproduced within 5 % variation among the laboratories. The results show that a good candidate for an SRM must have a highly square hysteresis loop (m r/m s > 90 %), H c ≈ 400 A·m(-1) (5 Oe), and m s ≈ 2 × 10(-7) A·m(2) (2 × 10(-4) emu).

  4. Final report on key comparison CCQM-K81: Chloramphenicol in pig muscle

    NASA Astrophysics Data System (ADS)

    Polzer, Joachim; Henrion, Andre; Gowik, Petra

    2013-01-01

    Under the auspices of the Organic Analysis Working Group (OAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a key comparison, CCQM-K81 'Chloramphenicol in pig muscle', was coordinated by BVL and PTB in 2009/2010. Six NMIs/DIs participated in this comparison. Chloramphenicol (CAP) is an effective broad-spectrum antibiotic which can in principle be used for the treatment of humans and animals. Its use for the treatment of food-producing animals is, however, forbidden worldwide in many countries due to potential severe side effects. The key comparison was the follow-up to the successful pilot study 'CCQM-P90: chloramphenicol in milk'. With this key comparison it was intended to demonstrate the capability of NMIs/DIs to analyse traces of CAP in food at concentration levels resulting from legal requirements for food control. Additionally, the quality of this kind of analysis with respect to compliance with legal requirements for food control methods and the international comparability of measurements should be evaluated in general. The study was classified as a 'track C' study (studies in emerging areas of global interest). For the study incurred lyophilised pig muscle material containing CAP (at a mass-fraction level around the maximum allowable level for import for a number of countries) has been produced as a candidate reference material by BVL and IRMM (Institute for Reference Materials and Measurements, JRC of the European Commission). Animal treatment and slaughtering of the animal to gain incurred muscle material as well as pre-testing of the CAP content was done at the BVL. The IRMM did further processing of the material and testing of homogeneity and stability. Participants were invited to assign the mass fraction of free CAP in the comparison sample. CCQM-K81 demonstrated successfully the capability of the participating laboratories to assign chloramphenicol values in tissue down to residue levels of around 0.3 ng/g (referring to the analyte content in reconstituted muscle material). Although very different sample preparation techniques (different pre-treatments, defattening steps, cartridges, solvents) as well as different analytical techniques (LC-MSMS, GC-MS, different instruments, columns, eluents) were applied to detect chloramphenicol at a very low concentration level, a KCRV of 0.267 ng/g with a satisfying expanded uncertainty of 17.4% was ascertained. Two of the reported results were not eligible to be used in establishing the KCRV; anyhow the KCRV as estimated from just the eligible results agrees very well with the additional results. With respect to legal requirements for quantitative methods for residue control in food the key comparison results prove the capabilities of the laboratories to fulfil these settings with highest precision and to provide calibration and measurement services to residue control laboratories. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Materials, processes, and environmental engineering network

    NASA Technical Reports Server (NTRS)

    White, Margo M.

    1993-01-01

    The Materials, Processes, and Environmental Engineering Network (MPEEN) was developed as a central holding facility for materials testing information generated by the Materials and Processes Laboratory. It contains information from other NASA centers and outside agencies, and also includes the NASA Environmental Information System (NEIS) and Failure Analysis Information System (FAIS) data. Environmental replacement materials information is a newly developed focus of MPEEN. This database is the NASA Environmental Information System, NEIS, which is accessible through MPEEN. Environmental concerns are addressed regarding materials identified by the NASA Operational Environment Team, NOET, to be hazardous to the environment. An environmental replacement technology database is contained within NEIS. Environmental concerns about materials are identified by NOET, and control or replacement strategies are formed. This database also contains the usage and performance characteristics of these hazardous materials. In addition to addressing environmental concerns, MPEEN contains one of the largest materials databases in the world. Over 600 users access this network on a daily basis. There is information available on failure analysis, metals and nonmetals testing, materials properties, standard and commercial parts, foreign alloy cross-reference, Long Duration Exposure Facility (LDEF) data, and Materials and Processes Selection List data.

  6. [Establishing biological reference intervals of alanine transaminase for clinical laboratory stored database].

    PubMed

    Guo, Wei; Song, Binbin; Shen, Junfei; Wu, Jiong; Zhang, Chunyan; Wang, Beili; Pan, Baishen

    2015-08-25

    To establish an indirect reference interval based on the test results of alanine aminotransferase stored in a laboratory information system. All alanine aminotransferase results were included for outpatients and physical examinations that were stored in the laboratory information system of Zhongshan Hospital during 2014. The original data were transformed using a Box-Cox transformation to obtain an approximate normal distribution. Outliers were identified and omitted using the Chauvenet and Tukey methods. The indirect reference intervals were obtained by simultaneously applying nonparametric and Hoffmann methods. The reference change value was selected to determine the statistical significance of the observed differences between the calculated and published reference intervals. The indirect reference intervals for alanine aminotransferase of all groups were 12 to 41 U/L (male, outpatient), 12 to 48 U/L (male, physical examination), 9 to 32 U/L (female, outpatient), and 8 to 35 U/L (female, physical examination), respectively. The absolute differences when compared with the direct results were all smaller than the reference change value of alanine aminotransferase. The Box-Cox transformation combined with the Hoffmann and Tukey methods is a simple and reliable technique that should be promoted and used by clinical laboratories.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adams, Wade C.

    Oak Ridge Institute for Science and Education (ORISE) personnel visited the United Nuclear Corporation (UNC) Naval Products site on three separate occasions during the months of October and November 2011. The purpose of these visits was to conduct confirmatory surveys of soils associated with the Argyle Street sewer line that was being removed. Soil samples were collected from six different, judgmentally determined locations in the Argyle Street sewer trench. In addition to the six soil samples collected by ORISE, four replicate soil samples were collected by Cabrera Services, Inc. (CSI) for analysis by the ORISE laboratory. Replicate samples S0010 andmore » S0011 were final status survey (FSS) bias samples; S0012 was an FSS systematic sample; and S0015 was a waste characterization sample. Six soil samples were also collected for background determination. Uranium-235 and uranium-238 concentrations were determined via gamma spectroscopy; the spectra were also reviewed for other identifiable photopeaks. Radionuclide concentrations for these soil samples are provided. In addition to the replicate samples and the samples collected by ORISE, CSI submitted three soil samples for inter-laboratory comparison analyses. One sample was from the background reference area, one was from waste characterization efforts (material inside the sewer line), and one was a FSS sample. The inter-laboratory comparison analyses results between ORISE and CSI were in agreement, except for one sample collected in the reference area. Smear results For Argyle Street sewer pipes are tabulated.« less

  8. Establishment of Traceability of Reference Grade Hydrometers at National Physical Laboratory, India (npli)

    NASA Astrophysics Data System (ADS)

    Kumar, Anil; Kumar, Harish; Mandal, Goutam; Das, M. B.; Sharma, D. C.

    The present paper discusses the establishment of traceability of reference grade hydrometers at National Physical Laboratory, India (NPLI). The reference grade hydrometers are calibrated and traceable to the primary solid density standard. The calibration has been done according to standard procedure based on Cuckow's Method and the reference grade hydrometers calibrated covers a wide range. The uncertainty of the reference grade hydrometers has been computed and corrections are also calculated for the scale readings, at which observations are taken.

  9. Quality assurance practices in Europe: a survey of molecular genetic testing laboratories

    PubMed Central

    Berwouts, Sarah; Fanning, Katrina; Morris, Michael A; Barton, David E; Dequeker, Elisabeth

    2012-01-01

    In the 2000s, a number of initiatives were taken internationally to improve quality in genetic testing services. To contribute to and update the limited literature available related to this topic, we surveyed 910 human molecular genetic testing laboratories, of which 291 (32%) from 29 European countries responded. The majority of laboratories were in the public sector (81%), affiliated with a university hospital (60%). Only a minority of laboratories was accredited (23%), and 26% was certified. A total of 22% of laboratories did not participate in external quality assessment (EQA) and 28% did not use reference materials (RMs). The main motivations given for accreditation were to improve laboratory profile (85%) and national recognition (84%). Nearly all respondents (95%) would prefer working in an accredited laboratory. In accredited laboratories, participation in EQA (P<0.0001), use of RMs (P=0.0014) and availability of continuous education (CE) on medical/scientific subjects (P=0.023), specific tasks (P=0.0018), and quality assurance (P<0.0001) were significantly higher than in non-accredited laboratories. Non-accredited laboratories expect higher restriction of development of new techniques (P=0.023) and improvement of work satisfaction (P=0.0002) than accredited laboratories. By using a quality implementation score (QIS), we showed that accredited laboratories (average score 92) comply better than certified laboratories (average score 69, P<0.001), and certified laboratories better than other laboratories (average score 44, P<0.001), with regard to the implementation of quality indicators. We conclude that quality practices vary widely in European genetic testing laboratories. This leads to a potentially dangerous situation in which the quality of genetic testing is not consistently assured. PMID:22739339

  10. Report on the U.S. Geological Survey's Evaluation Program Standard Reference Samples Distributed in October 1995: T-137 (Trace Constituents), M-136 (Major Constituents), N-47 (Nutrient Constituents), N-48 (Nutrient Constituents), P-25 (Low Ionic Strength Constituents), and Hg-21 (Mercury)

    USGS Publications Warehouse

    Farrar, Jerry W.; Long, H. Keith

    1996-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for 6 standard reference samples--T-137 (trace constituents), M-136 (major constituents), N-47 (nutrient constituents), N-48 (nutrient constituents), P-25 (low ionic strength constituents), and Hg-21 (mercury)--that were distributed in October 1995 to 149 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 136 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  11. Report on the U.S. Geological Survey's evaluation program for standard reference samples distributed in April 1994; T-129 (trace constituents), M-130 (major constituents), N-42 (nutrients), P-22 (low ionic strength), and Hg-18 (mercury)

    USGS Publications Warehouse

    Long, H. Keith; Farrar, Jerry W.

    1994-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for five standard reference samples--T-129 (trace constituents), M-130 (major constituents), N-42 (nutrients), P-22 (low ionic strength), Hg-18(mercury),--that were distributed in April 1994 to 157 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 133 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the five reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the five standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  12. Report of the U.S. Geological Survey's evaluation program for standard reference samples distributed in April 1993; T-123 (trace constituents), T-125 (trace constituents), M-126 (major constituents, N-38 (nutrients), N-39 (nutrients), P-20 (low ionic strength, and Hg-16 (mercury)

    USGS Publications Warehouse

    Long, H.K.; Farrar, J.W.

    1993-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for seven standard reference samples--T-123 (trace constituents), T-125 (trace constituents), M-126 (major constituents), N-38 (nutrients), N-39 (Nutrients), P-20 (precipitation-low ionic strength), and Hg-16 (mercury)--that were distributed in April 1993 to 175 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 131 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the 7 reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the seven standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  13. Results of the U.S. Geological Survey's Analytical Evaluation Program for standard reference samples distributed in March 1999

    USGS Publications Warehouse

    Farrar, Jerry W.; Chleboun, Kimberly M.

    1999-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for 8 standard reference samples -- T-157 (trace constituents), M-150 (major constituents), N-61 (nutrient constituents), N-62 (nutrient constituents), P-32 (low ionic strength constituents), GWT-5 (ground-water trace constituents), GWM- 4 (ground-water major constituents),and Hg-28 (mercury) -- that were distributed in March 1999 to 120 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 111 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the seven reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the 8 standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  14. Comparison of plasma ammonia results from seven different automated platforms in use throughout Central Australia.

    PubMed

    Markus, Corey; Metz, Michael

    2017-04-01

    The clinical catchment area for the Metabolic service at the Women's and Children's Hospital in Adelaide, South Australia, covers nearly 2.5millionkm 2 . Care of children with metabolic disorders in these remote areas is assisted from Adelaide, and at times, using plasma ammonia results from laboratories up to 3000km away. There are seven different platforms measuring plasma ammonia within this vast clinical catchment area. Hence, a correlation study was conducted to examine the relationship between plasma ammonia results from the seven different platforms in use throughout central Australia. Multiple aliquots of plasma from remainder EDTA samples for haematological investigations were frozen. Samples were then dispatched on dry ice to the laboratories being correlated. At an agreed date and time correlation samples were thawed and plasma ammonia measured. Passing-Bablok regression analysis showed slopes ranging from 1.00 to 1.10 and y-intercepts ranging from -10μmol/L to 1μmol/L. Despite the absence of a reference method or reference material and troublesome pre-analytical effects in ammonia measurement, plasma ammonia results from the different platforms in general compare well. The study also demonstrates that samples for ammonia measurement can be transported over great distances and still correlate well. Furthermore, a common reference interval for plasma ammonia may be a possibility. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  15. Commutability of the First World Health Organization International Standard for Human Cytomegalovirus

    PubMed Central

    Preiksaitis, J.; Tong, Y.; Pang, X.; Sun, Y.; Tang, L.; Cook, L.; Pounds, S.; Fryer, J.; Caliendo, A. M.

    2015-01-01

    Quantitative detection of cytomegalovirus (CMV) DNA has become a standard part of care for many groups of immunocompromised patients; recent development of the first WHO international standard for human CMV DNA has raised hopes of reducing interlaboratory variability of results. Commutability of reference material has been shown to be necessary if such material is to reduce variability among laboratories. Here we evaluated the commutability of the WHO standard using 10 different real-time quantitative CMV PCR assays run by eight different laboratories. Test panels, including aliquots of 50 patient samples (40 positive samples and 10 negative samples) and lyophilized CMV standard, were run, with each testing center using its own quantitative calibrators, reagents, and nucleic acid extraction methods. Commutability was assessed both on a pairwise basis and over the entire group of assays, using linear regression and correspondence analyses. Commutability of the WHO material differed among the tests that were evaluated, and these differences appeared to vary depending on the method of statistical analysis used and the cohort of assays included in the analysis. Depending on the methodology used, the WHO material showed poor or absent commutability with up to 50% of assays. Determination of commutability may require a multifaceted approach; the lack of commutability seen when using the WHO standard with several of the assays here suggests that further work is needed to bring us toward true consensus. PMID:26269622

  16. Postgraduate education on electro-active polymers at Southern Denmark University

    NASA Astrophysics Data System (ADS)

    Jones, Richard W.

    2009-03-01

    A recently introduced elective to the Master's of Science in Mechatronics program at Southern Denmark University, entitled 'Mechatronics: Design and Build' concentrates on some of the interdisciplinary aspects of Mechatronics Engineering. The 'Motion Control of Mechatronic Devices' is the main theme of this elective. Within this 'theme' the modelling, identification and compensation of nonlinear effects such as friction, stiction and hysteresis are considered. One of the most important components of the elective considers 'Smart Materials' and their use for actuation purposes. The theory, modelling and properties of piezoceramics. magneto- and electro- rheological fluids and dielectric electro active polymers (DEAP) are introduced in the 'Smart Materials' component. This paper initially reviews the laboratory experiments that have been developed for the dielectric electro active polymer section of the 'Mechatronics: Design and Build' elective. In lectures the students are introduced to the basic theory and fabrication of tubular actuators, that use DEAP material based on smart compliant electrode technology. In the laboratory the students to (a) carry out a series of experiments to characterise the tubular actuators, and (b) design a closed-loop position controller and test the performance of the controlled actuator for both step changes in desired position and periodic input reference signals. The last part of this contribution reviews some of the DEAP-based demonstration devices that been developed by Danfoss PolyPower A/S using their PolyPowerTM material which utilizes smart compliant electrode technology.

  17. Laboratories | NREL

    Science.gov Websites

    | Z A Accelerated Exposure Testing Laboratory Advanced Optical Materials Laboratory Advanced Thermal Laboratory Structural Testing Laboratory Surface Analysis Laboratory Systems Performance Laboratory T Thermal Storage Materials Laboratory Thermal Storage Process and Components Laboratory Thin-Film Deposition

  18. Guidelines for the detection of Trichinella larvae at the slaughterhouse in a quality assurance system.

    PubMed

    Rossi, Patrizia; Pozio, Edoardo

    2008-01-01

    The European Community Regulation (EC) No. 2075/2005 lays down specific rules on official controls for the detection of Trichinella in fresh meat for human consumption, recommending the pooled-sample digestion method as the reference method. The aim of this document is to provide specific guidance to implement an appropriate Trichinella digestion method by a laboratory accredited according to the ISO/IEC 17025:2005 international standard, and performing microbiological testing following the EA-04/10:2002 international guideline. Technical requirements for the correct implementation of the method, such as the personnel competence, specific equipments and reagents, validation of the method, reference materials, sampling, quality assurance of results and quality control of performance are provided, pointing out the critical control points for the correct implementation of the digestion method.

  19. Toward Clarity in Clinical Vitamin D Status Assessment: 25(OH)D Assay Standardization.

    PubMed

    Binkley, Neil; Carter, Graham D

    2017-12-01

    Widespread variation in 25-hydroxyvitamin D (25(OH)D) assays continues to compromise efforts to develop clinical and public health guidelines regarding vitamin D status. The Vitamin D Standardization Program helps alleviate this problem. Reference measurement procedures and standard reference materials have been developed to allow current, prospective, and retrospective standardization of 25(OH)D results. Despite advances in 25(OH)D measurement, substantial variability in clinical laboratory 25(OH)D measurement persists. Existing guidelines have not used standardized data and, as a result, it seems unlikely that consensus regarding definitions of vitamin D deficiency, inadequacy, sufficiency, and excess will soon be reached. Until evidence-based consensus is reached, a reasonable clinical approach is advocated. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Multicentre evaluation of stable reference whole blood for enumeration of lymphocyte subsets by flow cytometry.

    PubMed

    Edwards, Cherry; Belgrave, Danielle; Janossy, George; Bradley, Nicholas J; Stebbings, Richard; Gaines-Das, Rose; Thorpe, Robin; Sawle, Alex; Arroz, Maria Jorge; Brando, Bruno; Gratama, Jan Willem; Orfao de Matos, Alberto; Papa, Stephano; Papamichail, Michael; Lenkei, Rodica; Rothe, Gregor; Barnett, David

    2005-06-22

    BACKGROUND: Clinical indications for lymphocyte subset enumeration by flow cytometry include monitoring of disease progression and timing of therapeutic intervention in infection with human immunodeficiency virus. Until recently international standardisation has not been possible due to a lack of suitable stable reference material. METHODS: This study consisted of two trials of a stabilised whole blood preparation. Eleven participants were sent two standard protocols for staining plus gating strategy and asked to report absolute counts for lymphocyte subsets. RESULTS: No significant difference was detected between the two methods when results from the two assays and all partners were pooled. Significant differences in results from the different partners were observed. However, representative mean counts were obtained for geometric means, geometric coefficient of variation, and 95% confidence interval for CD3 910 cells/mul, 9%, and 888 to 933, respectively), CD4 (495 cells/mul, 12%, and 483 to 507), and CD8 (408 cells/mul, 13%, and 393 to 422). CONCLUSION: We have introduced a stabilised blood preparation and a well-characterized biological standard. The availability of this reference material greatly simplifies the validation of new techniques for CD4(+) T-cell enumeration and the expansion of external quality assurance programmes for clinical laboratories, including those that operate in resource-restricted environments. (c) 2005 Wiley-Liss, Inc.

  1. Reference measurement procedure for the determination of electrolytes in human blood via ICP-OES measurement

    NASA Astrophysics Data System (ADS)

    Grote-Koska, D.; Klauke, R.; Brand, K.; Schumann, G.

    2018-04-01

    The determination of electrolytes in human body fluids is one of the most frequently performed analyses in clinical routine laboratories. Metrological traceability of measurement results in patient samples is essential and requires the involvement of higher order reference measurement procedures wherever available. Here, the authors present the evaluation of a higher order reference system for the simultaneous determination of K+, Li+, Na+, Ca2+ and Mg2+ in blood serum and plasma. In the same order, the determined measurement performances were as follows: measurement ranges: 0.75 mmol l-1-75.0 mmol l-1, 0.05 mmol l-1-5.00 mmol l-1, 5 mmol l-1-200 mmol l-1, 0.4 mmol l-1-8.0 mmol l-1 and 0.1 mmol l-1-4.0 mmol l-1. Measurement imprecision: CVs were  ⩽1.1% for intra assay investigations and  ⩽1.8% for long term inter assay investigations for all measurands. Excellent accuracy was found testing certified Standard Reference Materials from NIST: SRM 909 (deviations from 0.0% to 1.1%) and SRM 956 (deviations from 0.0% to 1.5%). Intercomparisons with the German Metrology Institute (PTB) revealed differences from 0.1% to 0.8%. Matrix influences and carry over were not detectable. The expanded combined measurement uncertainties for the determination of the reference method values were estimated as  ⩾1.5% (k  =  2) for each measurand. The reference measurement procedure is accredited by the German accreditation body (DAkkS) in association with the German calibration service (DKD) according to ISO 17025 and ISO 15195. Services comprise the certification of calibrators, control materials and samples used in proficiency testing schemes.

  2. Determination of total sulfur in fertilizers by high temperature combustion: single-laboratory validation.

    PubMed

    Bernius, Jean; Kraus, Sabine; Hughes, Sandra; Margraf, Dominik; Bartos, James; Newlon, Natalie; Sieper, Hans-Peter

    2014-01-01

    Asingle-laboratory validation study was conducted for the determination of total sulfur (S) in a variety of common, inorganic fertilizers by combustion. The procedure involves conversion of S species into SO2 through combustion at 1150 degrees C, absorption then desorption from a purge and trap column, followed by measurement by a thermal conductivity detector. Eleven different validation materials were selected for study, which included four commercial fertilizer products, five fertilizers from the Magruder Check Sample Program, one reagent grade product, and one certified organic reference material. S content ranged between 1.47 and 91% as sulfate, thiosulfate, and elemental and organically bound S. Determinations of check samples were performed on 3 different days with four replicates/day. Determinations for non-Magruder samples were performed on 2 different days. Recoveries ranged from 94.3 to 125.9%. ABS SL absolute SD among runs ranged from 0.038 to 0.487%. Based on the accuracy and precision demonstrated here, it is recommended that this method be collaboratively studied for the determination of total S in fertilizers.

  3. Accuracy verification and identification of matrix effects. The College of American Pathologists' Protocol.

    PubMed

    Eckfeldt, J H; Copeland, K R

    1993-04-01

    Proficiency testing using stabilized control materials has been used for decades as a means of monitoring and improving performance in the clinical laboratory. Often, the commonly used proficiency testing materials exhibit "matrix effects" that cause them to behave differently from fresh human specimens in certain clinical analytic systems. Because proficiency testing is the primary method in which regulatory agencies have chosen to evaluate clinical laboratory performance, the College of American Pathologists (CAP) has proposed guidelines for investigating the influence of matrix effects on their Survey results. The purpose of this investigation was to determine the feasibility, usefulness, and potential problems associated with this CAP Matrix Effect Analytical Protocol, in which fresh patient specimens and CAP proficiency specimens are analyzed simultaneously by a field method and a definitive, reference, or other comparative method. The optimal outcome would be that both the fresh human and CAP Survey specimens agree closely with the comparative method result. However, this was not always the case. Using several different analytic configurations, we were able to demonstrate matrix and calibration biases for several of the analytes investigated.

  4. Fracture and matrix hydrologic characteristics of tuffaceous materials from Yucca Mountain, Nye County, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, R.R.; Klavetter, E.A.; Hall, I.J.

    1984-12-01

    The geological formations in the unsaturated zone at Yucca Mountain, on and adjacent to the Nevada Test Site (NTS), are currently being studied for consideration as the host for a radioactive-waste repository; the US Department of Energy is carrying out these studies through the Nevada Nuclear Waste Storage Investigations project. The formations are composed of tuffaceous (tuff) materials that must be evaluated to estimate the rate at which radionuclides would migrate to the accessible environment. According to the available evidence, the flux of water in the unsaturated zone beneath the Yucca Mountain site is low; quantifying such low flow ratesmore » through direct measurements is difficult. To help provide data that can be used to assess unsaturated flow, Pacific Northwest Laboratory (PNL), under contract to Sandia National Laboratories (SNL), performed hydrologic tests on tuffaceous samples from 48 different locations in Yucca Mountain. This report contains the entire set of psychrometer measurements of desaturation curves for tuffs from Yucca Mountain as well as a substantial number of saturated conductivity measurements. 19 references, 132 figures, 23 tables.« less

  5. Clay pigment structure characterisation as a guide for provenance determination--a comparison between laboratory powder micro-XRD and synchrotron radiation XRD.

    PubMed

    Švarcová, Silvie; Bezdička, Petr; Hradil, David; Hradilová, Janka; Žižak, Ivo

    2011-01-01

    Application of X-ray diffraction (XRD)-based techniques in the analysis of painted artworks is not only beneficial for indisputable identification of crystal constituents in colour layers, but it can also bring insight in material crystal structure, which can be affected by their geological formation, manufacturing procedure or secondary changes. This knowledge might be helpful for art historic evaluation of an artwork as well as for its conservation. By way of example of kaolinite, we show that classification of its crystal structure order based on XRD data is useful for estimation of its provenance. We found kaolinite in the preparation layer of a Gothic wall painting in a Czech church situated near Karlovy Vary, where there are important kaolin deposits. Comparing reference kaolin materials from eight various Czech deposits, we found that these can be differentiated just according to the kaolinite crystallinity. Within this study, we compared laboratory powder X-ray micro-diffraction (micro-XRD) with synchrotron radiation X-ray diffraction analysing the same real sample. We found that both techniques led to the same results.

  6. Hazardous materials information hotline using System 2000

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brower, J.E.; Fuchel, K.

    1984-04-30

    The Center for Assessment of Chemical and Physical Hazards (CACPH) at Brookhaven National Laboratory (BNL) has developed a computer hotline service for the Department of Energy (DOE) and its contractors. This service provides access to health and safety information for over 800 chemicals and hazardous materials. The data base uses System 2000 on a CDC 6600 and provides information on the chemical name and its synonyms, 17 categories of health and safety information, composition of chemical mixtures, categories of chemicals, use and hazards, and physical, chemical and toxicity attributes. In order to make this information available to people unfamiliar withmore » System 2000, a user-friendly interface was developed using a Fortran PLEX Program. 1 reference, 1 figure.« less

  7. Certification of the Uranium Isotopic Ratios in Nbl Crm 112-A, Uranium Assay Standard (Invited)

    NASA Astrophysics Data System (ADS)

    Mathew, K. J.; Mason, P.; Narayanan, U.

    2010-12-01

    Isotopic reference materials are needed to validate measurement procedures and to calibrate multi-collector ion counting detector systems. New Brunswick Laboratory (NBL) provides a suite of certified isotopic and assay standards for the US and international nuclear safeguards community. NBL Certified Reference Material (CRM) 112-A Uranium Metal Assay Standard with a consensus value of 137.88 for the 238U/235U ratio [National Bureau of Standards -- NBS, currently named National Institute for Standards and Technology, Standard Reference Material (SRM) 960 had been renamed CRM 112-A] is commonly used as a natural uranium isotopic reference material within the earth science community. We have completed the analytical work for characterizing the isotopic composition of NBL CRM 112-A Uranium Assay Standard and NBL CRM 145 (uranyl nitrate solution prepared from CRM 112-A). The 235U/238U isotopic ratios were characterized using the total evaporation (TE) and the modified total evaporation (MTE) methods. The 234U/238U isotope ratios were characterized using a conventional analysis technique and verified using the ratios measured in the MTE analytical technique. The analysis plan for the characterization work was developed such that isotopic ratios that are traceable to NBL CRM U030-A are obtained. NBL is preparing a certificate of Analysis and will issue a certificate for Uranium Assay and Isotopics. The results of the CRM 112-A certification measurements will be discussed. These results will be compared with the average values from Richter et al (2010). A comparison of the precision and accuracy of the measurement methods (TE, MTE and Conventional) employed in the certification will be presented. The uncertainties in the 235U/238U and 234U/238U ratios, calculated according to the Guide to the Expression of Uncertainty in Measurements (GUM) and the dominant contributors to the combined standard uncertainty will be discussed.

  8. Instantaneous progression reference frame for calculating pelvis rotations: Reliable and anatomically-meaningful results independent of the direction of movement.

    PubMed

    Kainz, Hans; Lloyd, David G; Walsh, Henry P J; Carty, Christopher P

    2016-05-01

    In motion analysis, pelvis angles are conventionally calculated as the rotations between the pelvis and laboratory reference frame. This approach assumes that the participant's motion is along the anterior-posterior laboratory reference frame axis. When this assumption is violated interpretation of pelvis angels become problematic. In this paper a new approach for calculating pelvis angles based on the rotations between the pelvis and an instantaneous progression reference frame was introduced. At every time-point, the tangent to the trajectory of the midpoint of the pelvis projected into the horizontal plane of the laboratory reference frame was used to define the anterior-posterior axis of the instantaneous progression reference frame. This new approach combined with the rotation-obliquity-tilt rotation sequence was compared to the conventional approach using the rotation-obliquity-tilt and tilt-obliquity-rotation sequences. Four different movement tasks performed by eight healthy adults were analysed. The instantaneous progression reference frame approach was the only approach that showed reliable and anatomically meaningful results for all analysed movement tasks (mean root-mean-square-differences below 5°, differences in pelvis angles at pre-defined gait events below 10°). Both rotation sequences combined with the conventional approach led to unreliable results as soon as the participant's motion was not along the anterior-posterior laboratory axis (mean root-mean-square-differences up to 30°, differences in pelvis angles at pre-defined gait events up to 45°). The instantaneous progression reference frame approach enables the gait analysis community to analysis pelvis angles for movements that do not follow the anterior-posterior axis of the laboratory reference frame. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Long-term pavement performance project laboratory materials testing and handling guide

    DOT National Transportation Integrated Search

    2007-09-01

    The Long Term Pavement Performance (LTPP) Laboratory Material Testing Guide was originally prepared for laboratory material handling and testing of material specimens and samples of asphalt materials, portland cement concrete, aggregates, and soils u...

  10. Quality assurance of reference standards from nine European solar-ultraviolet monitoring laboratories.

    PubMed

    Gröbner, Julian; Rembges, Diana; Bais, Alkiviadis F; Blumthaler, Mario; Cabot, Thierry; Josefsson, Weine; Koskela, Tapani; Thorseth, Trond M; Webb, Ann R; Wester, Ulf

    2002-07-20

    A program for quality assurance of reference standards has been initiated among nine solar-UV monitoring laboratories. By means of a traveling lamp package that comprises several 1000-W ANSI code DXW-type quartz-halogen lamps, a 0.1-ohm shunt, and a 6-1/2 digit voltmeter, the irradiance scales used by the nine laboratories were compared with one another; a relative uncertainty of 1.2% was found. The comparison of 15 reference standards yielded differences of as much as 9%; the average difference was less than 3%.

  11. International reference preparations of typhoid vaccine

    PubMed Central

    Melikova, E. N.; Lesnjak, S. V.

    1967-01-01

    International collaborative laboratory studies on the International Reference Preparations of Typhoid Vaccine have so far failed to provide data on which international units for these vaccines can be based. Further assays carried out using the active mouse protection test, with immunization by the subcutaneous, intraperitoneal or intravenous route, confirmed the findings by some workers that the International Reference Preparation of Typhoid Vaccine (Acetone-Inactivated) (vaccine K) was more effective than the International Reference Preparation of Typhoid Vaccine (Heat-Phenol-Inactivated) (vaccine L), and indicated that intraperitoneal immunization was the most promising method. Vaccine K, together with the material extracted by the acetone in the preparation of the vaccine, had a significantly lower effectiveness (at the 5% probability level) only when intraperitoneal immunization was used. The reasons for the differences found between the various vaccines and routes of immunization are discussed at length. It is suggested that challenge with a strain of Salmonella moscow instead of the strain of Salm. typhi used until now gives a true infection and forms the basis of a reliable method for the potency assay of typhoid vaccines. PMID:5301738

  12. Frames of Reference in the Classroom

    NASA Astrophysics Data System (ADS)

    Grossman, Joshua

    2012-12-01

    The classic film "Frames of Reference"1,2 effectively illustrates concepts involved with inertial and non-inertial reference frames. In it, Donald G. Ivey and Patterson Hume use the cameras perspective to allow the viewer to see motion in reference frames translating with a constant velocity, translating while accelerating, and rotating—all with respect to the Earth frame. The film is a classic for good reason, but today it does have a couple of drawbacks: 1) The film by nature only accommodates passive learning. It does not give students the opportunity to try any of the experiments themselves. 2) The dated style of the 50-year-old film can distract students from the physics content. I present here a simple setup that can recreate many of the movies demonstrations in the classroom. The demonstrations can be used to supplement the movie or in its place, if desired. All of the materials except perhaps the inexpensive web camera should likely be available already in most teaching laboratories. Unlike previously described activities, these experiments do not require travel to another location3 or an involved setup.4,5

  13. Measurement of the Two-photon Absorption Coefficient of Gallium Phosphide (GaP) Using a Dispersion-minimized Sub-10 Femtosecond Z-scan Measurement System

    DTIC Science & Technology

    2012-09-01

    bandwidth of the pulse. Using the standard laboratory and analysis methods of Sheik- Bahae et al., we obtain a two-photon absorption coefficient, β, of...organic thin-film materials deposited on various substrates. 15 6. References 1. Sheik- Bahae , M.; Said, A. A.; Van Stryland, E. W. High...sensitivity, Single-beam n2 Measurements. Optics Letters 1989, 14 (17). 2. Sheik- Bahae , M.; Said, A. A.; Van Stryland, E. W.; Wei, T-H; Hagan, D. J

  14. Recent Progresses in Laboratory Astrophysics with Ames’ COSmIC Facility

    NASA Astrophysics Data System (ADS)

    Salama, Farid; Contreras, Cesar; Sciamma-O'Brien, Ella; Bejaoui, Salma

    2016-06-01

    We present and discuss the characteristics and the capabilities of the laboratory facility, COSmIC, that was developed at NASA Ames to generate, process and analyze interstellar, circumstellar and planetary analogs in the laboratory [1]. COSmIC stands for “Cosmic Simulation Chamber” and is dedicated to the study of neutral and ionized molecules and nano particles under the low temperature and high vacuum conditions that are required to simulate space environments. COSmIC integrates a variety of state-of-the-art instruments that allow forming, processing and monitoring simulated space conditions for planetary, circumstellar and interstellar materials in the laboratory. COSmIC is composed of a Pulsed Discharge Nozzle (PDN) expansion that generates a plasma in free supersonic jet expansion coupled to two high-sensitivity, complementary in situ diagnostics: a Cavity Ring Down Spectroscopy (CRDS) and laser induced fluorescence (LIF) systems for photonic detection and a Reflectron Time-Of-Flight Mass Spectrometer (ReTOF-MS) for mass detection [2].Recent laboratory results that were obtained using COSmIC will be presented, in particular the progress that has been achieved in the domain of the diffuse interstellar bands (DIBs) [3] and in monitoring, in the laboratory, the formation of dust grains and aerosols from their gas-phase molecular precursors in environments as varied as stellar/circumstellar outflows [4] and planetary atmospheres [5]. Plans for future, next generation, laboratory experiments on cosmic molecules and grains in the growing field of laboratory astrophysics will also be addressed as well as the implications of the current studies for astronomy.References: [1] Salama F., In Organic Matter in Space, IAU Symposium 251, Kwok & Sandford Eds.Cambridge University Press, Vol. 4, S251, p. 357 (2008) and references therein.[2] Ricketts C., Contreras C., Walker, R., Salama F., Int. J. Mass Spec, 300, 26 (2011)[3] Salama F., Galazutdinov G., Krelowski J., Biennier L., Beletsky Y., In-Ok Song, The Astrophys. J., 728, 154 (2011)[4] Cesar Contreras and Farid Salama, The Astrophys. J. Suppl. Ser., 208, 6 (2013)[5] Sciamma-O'Brien E., Ricketts C., and Salama F. Icarus, 243, 325 (2014)Acknowledgements: The authors acknowledge the support of NASA SMD.

  15. Effect of Transitioning from Standard Reference Material 2806a to Standard Reference Material 2806b for Light Obscuration Particle Countering

    DTIC Science & Technology

    2016-04-01

    Reference Material 2806b for Light Obscuration Particle Countering April 2016 UNCLASSIFIED UNCLASSIFIED Joel Schmitigal 27809 Standard Form 298 (Rev...Standard Reference Material 2806b for Light Obscuration Particle Countering 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6...Reference Material 2806a to Standard Reference Material 2806b for Light Obscuration Particle Countering Joel Schmitigal Force Projection

  16. The Air Force's central reference laboratory: maximizing service while minimizing cost.

    PubMed

    Armbruster, D A

    1991-11-01

    The Laboratory Services Branch (Epi Lab) of the Epidemiology Division, Brooks AFB, Texas, is designated by regulation to serve as the Air Force's central reference laboratory, providing clinical laboratory testing support to all Air Force medical treatment facilities (MTFs). Epi Lab recognized that it was not offering the MTFs a service comparable to civilian reference laboratories and that, as a result, the Air Force medical system was spending hundreds of thousands of dollars yearly for commercial laboratory support. An in-house laboratory upgrade program was proposed to and approved by the USAF Surgeon General, as a Congressional Efficiencies Add project, to launch a two-phase initiative consisting of a 1-year field trial of 30 MTFs, followed by expansion to another 60 MTFs. Major components of the program include overnight air courier service to deliver patient samples to Epi Lab, a mainframe computer laboratory information system and electronic reporting of results to the MTFs throughout the CONUS. Application of medical marketing concepts and the Total Quality Management (TQM) philosophy allowed Epi to provide dramatically enhanced reference service at a cost savings of about $1 million to the medical system. The Epi Lab upgrade program represents an innovative problem-solving approach, combining technical and managerial improvements, resulting in substantial patient care service and financial dividends. It serves as an example of successful application of TQM and marketing within the military medical system.

  17. New quality-control materials for the determination of alkylphenols and alkylphenol ethoxylates in sewage sludge.

    PubMed

    Fernández-Sanjuan, María; Lacorte, Silvia; Rigol, Anna; Sahuquillo, Angels

    2012-11-01

    The determination of alkylphenols in sewage sludge is still hindered by the complexity of the matrix and of the analytes, some of which are a mixture of isomers. Most of the methods published in the literature have not been validated, due to the lack of reference materials for the determination of alkylphenols in sludge. Given this situation, the objectives of the present study were to develop a new quality-control material for determining octylphenol, nonylphenol and nonylphenol monoethoxylate in sludge. The material was prepared from an anaerobically digested sewage sludge, which was thermally dried, sieved, homogenized and bottled after checking for the bulk homogeneity of the processed material. Together with the sewage sludge, an extract was also prepared, in order to provide a quality-control material for allowing laboratories to test the measuring step. The homogeneity and 1-year stability of the two materials were evaluated. Statistical analysis proved that the materials were homogeneous and stable for at least 1 year stored at different temperatures. These materials are intended to assist in the quality control of the determination of alkylphenols and alkylphenol ethoxylates in sewage sludge.

  18. Age and sex variation in serum albumin concentration: an observational study.

    PubMed

    Weaving, Gary; Batstone, Gifford F; Jones, Richard G

    2016-01-01

    In the UK, a common reference interval for serum albumin is widely used irrespective of age or sex. Implicit in this is that laboratories produce analytically similar results. This paper challenges the validity of this approach. A three-week collection of results sent to all primary care centres in England has been analysed by age, sex and laboratory. In all, 1,079,193 serum albumin reports were included in this analysis. The mean population serum albumin concentration increases to peak at around age 20 years and then decreases with increasing age. Values in females decrease more rapidly but become close to male values at 60 years. The variation between laboratories was large and potentially clinically significant. Reference intervals for serum albumin should be stratified by age and sex. Until there is greater methodological standardization, laboratories should determine their own reference intervals and not accept a single consensus reference interval. © The Author(s) 2015.

  19. Uranium and Calcium Isotope Ratio Measurements using the Modified Total Evaporation Method in TIMS

    NASA Astrophysics Data System (ADS)

    Richter, S.; Kuehn, H.; Berglund, M.; Hennessy, C.

    2010-12-01

    A new version of the "modified total evaporation" (MTE) method for isotopic analysis by multi-collector thermal ionization mass spectrometry (TIMS), with high analytical performance and designed in a more user-friendly and routinely applicable way, is described in detail. It is mainly being used for nuclear safeguards measurements of U and Pu and nuclear metrology, but can readily be applied to other scientific tasks in geochemistry, e.g. for Sr, Nd and Ca, as well. The development of the MTE method was organized in collaboration of several "key nuclear mass spectrometry laboratories", namely the New Brunswick Laboratory (NBL), the Institute for Transuranium Elements (ITU), the Safeguards Analytical Laboratory (now Safeguards Analytical Services, SGAS) of the International Atomic Energy Agency (IAEA) and the Institute for Reference Materials and Measurements (IRMM), with IRMM taking the leading role. The manufacturer of the TRITON TIMS instrument, Thermo Fisher Scientific, integrated this method into the software of the instrument. The development has now reached its goal to become a user-friendly and routinely useable method for uranium isotope ratio measurements with high precision and accuracy. Due to the use of the “total evaporation” (TE) method the measurement of the "major" uranium isotope ratio 235U/238U is routinely being performed with a precision of 0.01% to 0.02%. The use of a (certified) reference material measured under comparable conditions is emphasized to achieve an accuracy at a level of 0.02% - depending on the stated uncertainty of the certified value of the reference material. In contrast to the total evaporation method (TE), in the MTE method the total evaporation sequence is interrupted on a regular basis to allow for correction for background from peak tailing, internal calibration of a secondary electron multiplier (SEM) detector versus the Faraday cups, and ion source re-focusing. Therefore, the most significant improvement using the MTE method is in the analytical performance achieved for the "minor" ratios 234U/238U and 236U/238U. The MTE method is now routinely used at all collaborating laboratories and possibly more in the future. Additional applications for the MTE method, e.g. to take advantage of the good external precision in combination with the possibilities of internal background and detector calibrations or mass jumps between different cup configurations, are presented as well. One interesting application concerns new absolute isotope ratio measurements for Ca with an unprecedented level of accuracy. This is important because up to now most reported Ca isotope data are only calculated as relative deviations from a standard like NIST-SRM 915. Using the MTE method measurements on new gravimetrically prepared Ca isotope mixtures were performed. A significantly improved level of accuracy at the level of about 0.02% for both the 42Ca/40Ca and 44Ca/40Ca ratios was obtained.

  20. The natural aging of austenitic stainless steels irradiated with fast neutrons

    NASA Astrophysics Data System (ADS)

    Rofman, O. V.; Maksimkin, O. P.; Tsay, K. V.; Koyanbayev, Ye. T.; Short, M. P.

    2018-02-01

    Much of today's research in nuclear materials relies heavily on archived, historical specimens, as neutron irradiation facilities become ever more scarce. These materials are subject to many processes of stress- and irradiation-induced microstructural evolution, including those during and after irradiation. The latter of these, referring to specimens "naturally aged" in ambient laboratory conditions, receives far less attention. The long and slow set of rare defect migration and interaction events during natural aging can significantly change material properties over decadal timescales. This paper presents the results of natural aging carried out over 15 years on austenitic stainless steels from a BN-350 fast breeder reactor, each with its own irradiation, stress state, and natural aging history. Natural aging is shown to significantly reduce hardness in these steels by 10-25% and partially alleviate stress-induced hardening over this timescale, showing that materials evolve back towards equilibrium even at such a low temperature. The results in this study have significant implications to any nuclear materials research program which uses historical specimens from previous irradiations, challenging the commonly held assumption that materials "on the shelf" do not evolve.

Top