Childress, Carolyn J. Oblinger; Foreman, William T.; Connor, Brooke F.; Maloney, Thomas J.
1999-01-01
This report describes the U.S. Geological Survey National Water Quality Laboratory?s approach for determining long-term method detection levels and establishing reporting levels, details relevant new reporting conventions, and provides preliminary guidance on interpreting data reported with the new conventions. At the long-term method detection level concentration, the risk of a false positive detection (analyte reported present at the long-term method detection level when not in sample) is no more than 1 percent. However, at the long-term method detection level, the risk of a false negative occurrence (analyte reported not present when present at the long-term method detection level concentration) is up to 50 percent. Because this false negative rate is too high for use as a default 'less than' reporting level, a more reliable laboratory reporting level is set at twice the determined long-term method detection level. For all methods, concentrations measured between the laboratory reporting level and the long-term method detection level will be reported as estimated concentrations. Non-detections will be censored to the laboratory reporting level. Adoption of the new reporting conventions requires a full understanding of how low-concentration data can be used and interpreted and places responsibility for using and presenting final data with the user rather than with the laboratory. Users must consider that (1) new laboratory reporting levels may differ from previously established minimum reporting levels, (2) long-term method detection levels and laboratory reporting levels may change over time, and (3) estimated concentrations are less certain than concentrations reported above the laboratory reporting level. The availability of uncensored but qualified low-concentration data for interpretation and statistical analysis is a substantial benefit to the user. A decision to censor data after they are reported from the laboratory may still be made by the user, if merited, on the basis of the intended use of the data.
Kiel, Elizabeth J.; Hummel, Alexandra C.
2016-01-01
Emotion and temperament researchers have faced an enduring issue of how to best measure children’s tendencies to express specific emotions. Inconsistencies between laboratory observation and parental report have made it challenging for researchers to determine the utility of these different forms of measurement. The current study examined the effect of laboratory episode characteristics (i.e., threat-level of the episode, maternal involvement) on concordance between maternal report and laboratory observation of toddler fear. The sample included 111 mother-toddler dyads who participated in a laboratory assessment when toddlers were approximately 24-months-old. Toddler fear was assessed both via maternal report and observation from a number of laboratory episodes that varied in their level of threat and whether mothers were free or constrained in their involvement in the task. Results indicated that maternal report related to the observed fear composites for low-threat, but not high-threat episodes. On the other hand, maternal involvement in the laboratory episodes did not moderate the relation between maternal report and laboratory observation of fear. These results suggest that the threat-level of laboratory episodes designed to elicit fear, but not maternal involvement in these episodes, may be important to take into consideration when assessing their relation to maternal report of fear and fearful temperament. PMID:27606826
Laboratory Projects: Should Students Do Them or Design Them?
ERIC Educational Resources Information Center
Middelberg, Anton P. J.
1995-01-01
Describes changes initiated in the Level-Three laboratory course of the chemical engineering curriculum at the University of Adelaide that were useful in fostering higher-level skills and reducing the reliance on reports handed down from previous years. Highlights report writing and data analysis workshops and the laboratory project design…
The development of registries for surveillance of adult lead exposure, 1981 to 1992.
Baser, M E
1992-08-01
Since 1981, 15 states have established registries for surveillance of adult lead absorption, primarily based on reports of elevated blood lead levels from clinical laboratories. I review the status of the registries and recommend steps for further development. Companies reported to the New York registry are compared with those cited by the Occupational Safety and Health Administration (OSHA). I present data on US workers and plants with potential lead exposures and blood tests, as well as review registries' reporting requirements. Registries identify many companies not cited by the Occupational Safety and Health Administration, but underreporting occurs because (1) reporting is usually not required from laboratories outside the state, (2) most registries use a blood lead reporting level of 1.21 mumol/L, which excludes many exposed workers, and (3) many companies with potential exposures do not have routine monitoring programs. Registries' reporting requirements and procedures should be standardized, including a blood lead reporting level of 0.72 mumol/L. Elevated blood lead levels should be a reportable condition nationwide, and a comprehensive national surveillance system should be established: clinical laboratories should be required to report cases to those states with lead registries or directly to the national adult lead registry.
Over-reporting significant figures--a significant problem?
Hawkins, Robert C; Badrick, Tony; Hickman, Peter E
2007-01-01
Excessive use of significant figures in numerical data gives a spurious impression of laboratory imprecision to clinicians. We describe reporting practices in 24 Asia-Pacific laboratories, assess whether these reporting formats and those used in the literature can be justified based on actual laboratory performance and outline how to choose the appropriate number of significant places. Thirty-two laboratories in Asia-Pacific were surveyed as to their reporting practices for serum creatinine, ferritin, sodium and TSH. Imprecision data from the General Serum Chemistry program from the RCPA-AACB Quality Assurance Program (QAP) were used to assess whether the reporting unit magnitude implicitly suggested in Tietz, the RCPA Manual and the General Serum Chemistry program itself was justified. There was a 75% response rate to the survey, with laboratories generally reporting data using unjustifiable deciles. Unit sizes from the RCPA manual, Tietz and the RCPA-AACB QAP were not justified by the majority of laboratories in the RCPA-AACB QAP. The reporting unit size used by many laboratories is not justified by present laboratory performance using a 95% probability level. A consensus on appropriate reporting unit size is needed to encourage laboratories to change their present reporting formats.
Physiology undergraduate degree requirements in the U.S.
VanRyn, Valerie S; Poteracki, James M; Wehrwein, Erica A
2017-12-01
Course-level learning objectives and core concepts for undergraduate physiology teaching exist. The next step is to consider how these resources fit into generalizable program-level guidelines for Bachelor of Science (BS) degrees in Physiology. In the absence of program-level guidelines for Physiology degree programs, we compiled a selective internal report to review degree requirements from 18 peer BS programs entitled "Physiology" in the United States (U.S.). There was a range of zero to three required semesters of math, physics, physics laboratory, general biology, biology laboratory, general chemistry, chemistry laboratory, organic chemistry, organic chemistry laboratory, biochemistry, biochemistry laboratory, anatomy, anatomy laboratory, core systems physiology, and physiology laboratory. Required upper division credits ranged from 11 to 31 and included system-specific, exercise and environmental, clinically relevant, pathology/disease-related, and basic science options. We hope that this information will be useful for all programs that consider themselves to be physiology, regardless of name. Reports such as this can serve as a starting point for collaboration among BS programs to improve physiology undergraduate education and best serve our students. Copyright © 2017 the American Physiological Society.
Syphilis testing practices in the Americas.
Trinh, Thuy T; Kamb, Mary L; Luu, Minh; Ham, D Cal; Perez, Freddy
2017-09-01
To present the findings of the Pan American Health Organization's 2014 survey on syphilis testing policies and practices in the Americas. Representatives of national/regional reference and large, lower-level laboratories from 35 member states were invited to participate. A semi-structured, electronically administered questionnaire collected data on syphilis tests, algorithms, equipment/commodities, challenges faced and basic quality assurance (QA) strategies employed (i.e. daily controls, standard operating procedures, technician training, participating in external QA programmes, on-site evaluations). The 69 participating laboratories from 30 (86%) member states included 41 (59%) national/regional reference and 28 (41%) lower-level laboratories. Common syphilis tests conducted were the rapid plasma reagin (RPR) (62% of surveyed laboratories), venereal disease research laboratory (VDRL) (54%), fluorescent treponemal antibody absorption (FTA-ABS) (41%) and Treponema pallidum haemagglutination assay (TPHA) (32%). Only three facilities reported using direct detection methods, and 28 (41% overall, 32% of lower-level facilities) used rapid tests. Most laboratories (62%) used only traditional testing algorithms (non-treponemal screening and treponemal confirmatory testing); however, 12% used only a reverse sequence algorithm (treponemal test first), and 14% employed both algorithms. Another nine (12%) laboratories conducted only one type of serologic test. Although most reference (97%) and lower-level (89%) laboratories used at least one QA strategy, only 16% reported using all five basic strategies. Commonly reported challenges were stock-outs of essential reagents or commodities (46%), limited staff training (73%) and insufficient equipment (39%). Many reference and clinical laboratories in the Americas face challenges in conducting appropriate syphilis testing and in ensuring quality of testing. © 2017 John Wiley & Sons Ltd The Pan-American Health Organization retains copyright and all other rights in the manuscript of this article as submitted for publication.
The Master level optics laboratory at the Institute of Optics
NASA Astrophysics Data System (ADS)
Adamson, Per
2017-08-01
The master level optics laboratory is a biannual, intensive laboratory course in the fields of geometrical, physical and modern optics. This course is intended for the master level student though Ph.D. advisors which often recommend it to their advisees. The students are required to complete five standard laboratory experiments and an independent project during a semester. The goals of the laboratory experiments are for the students to get hands-on experience setting up optical laboratory equipment, collecting and analyzing data, as well as to communicate key results. The experimental methods, analysis, and results of the standard experiments are submitted in a journal style report, while an oral presentation is given for the independent project.
Brigati, Jennifer R.; Swann, Jerilyn M.
2015-01-01
Incorporating peer-review steps in the laboratory report writing process provides benefits to students, but it also can create additional work for laboratory instructors. The laboratory report writing process described here allows the instructor to grade only one lab report for every two to four students, while giving the students the benefits of peer review and prompt feedback on their laboratory reports. Here we present the application of this process to a sophomore level genetics course and a freshman level cellular biology course, including information regarding class time spent on student preparation activities, instructor preparation, prerequisite student knowledge, suggested learning outcomes, procedure, materials, student instructions, faculty instructions, assessment tools, and sample data. T-tests comparing individual and group grading of the introductory cell biology lab reports yielded average scores that were not significantly different from each other (p = 0.13, n = 23 for individual grading, n = 6 for group grading). T-tests also demonstrated that average laboratory report grades of students using the peer-review process were not significantly different from those of students working alone (p = 0.98, n = 9 for individual grading, n = 6 for pair grading). While the grading process described here does not lead to statistically significant gains (or reductions) in student learning, it allows student learning to be maintained while decreasing instructor workload. This reduction in workload could allow the instructor time to pursue other high-impact practices that have been shown to increase student learning. Finally, we suggest possible modifications to the procedure for application in a variety of settings. PMID:25949758
Brigati, Jennifer R; Swann, Jerilyn M
2015-05-01
Incorporating peer-review steps in the laboratory report writing process provides benefits to students, but it also can create additional work for laboratory instructors. The laboratory report writing process described here allows the instructor to grade only one lab report for every two to four students, while giving the students the benefits of peer review and prompt feedback on their laboratory reports. Here we present the application of this process to a sophomore level genetics course and a freshman level cellular biology course, including information regarding class time spent on student preparation activities, instructor preparation, prerequisite student knowledge, suggested learning outcomes, procedure, materials, student instructions, faculty instructions, assessment tools, and sample data. T-tests comparing individual and group grading of the introductory cell biology lab reports yielded average scores that were not significantly different from each other (p = 0.13, n = 23 for individual grading, n = 6 for group grading). T-tests also demonstrated that average laboratory report grades of students using the peer-review process were not significantly different from those of students working alone (p = 0.98, n = 9 for individual grading, n = 6 for pair grading). While the grading process described here does not lead to statistically significant gains (or reductions) in student learning, it allows student learning to be maintained while decreasing instructor workload. This reduction in workload could allow the instructor time to pursue other high-impact practices that have been shown to increase student learning. Finally, we suggest possible modifications to the procedure for application in a variety of settings.
ERIC Educational Resources Information Center
National Heart, Lung, and Blood Inst. (DHHS/NIH), Bethesda, MD.
Precise and accurate cholesterol measurements are required to identify and treat individuals with high blood cholesterol levels. However, the current state of reliability of blood cholesterol measurements suggests that considerable inaccuracy in cholesterol testing exists. This report describes the Laboratory Standardization Panel findings on the…
Sujansky, Walter V; Overhage, J Marc; Chang, Sophia; Frohlich, Jonah; Faus, Samuel A
2009-01-01
Electronic laboratory interfaces can significantly increase the value of ambulatory electronic health record (EHR) systems by providing laboratory result data automatically and in a computable form. However, many ambulatory EHRs cannot implement electronic laboratory interfaces despite the existence of messaging standards, such as Health Level 7, version 2 (HL7). Among several barriers to implementing laboratory interfaces is the extensive optionality within the HL7 message standard. This paper describes the rationale for and development of an HL7 implementation guide that seeks to eliminate most of the optionality inherent in HL7, but retain the information content required for reporting outpatient laboratory results. A work group of heterogeneous stakeholders developed the implementation guide based on a set of design principles that emphasized parsimony, practical requirements, and near-term adoption. The resulting implementation guide contains 93% fewer optional data elements than HL7. This guide was successfully implemented by 15 organizations during an initial testing phase and has been approved by the HL7 standards body as an implementation guide for outpatient laboratory reporting. Further testing is required to determine whether widespread adoption of the implementation guide by laboratories and EHR systems can facilitate the implementation of electronic laboratory interfaces.
Syphilis testing in antenatal care: Policies and practices among laboratories in the Americas.
Luu, Minh; Ham, Cal; Kamb, Mary L; Caffe, Sonja; Hoover, Karen W; Perez, Freddy
2015-06-01
To asses laboratory syphilis testing policies and practices among laboratories in the Americas. Laboratory directors or designees from PAHO member countries were invited to participate in a structured, electronically-delivered survey between March and August, 2014. Data on syphilis tests, algorithms, and quality control (QC) practices were analyzed, focusing on laboratories receiving specimens from antenatal clinics (ANCs). Surveys were completed by 69 laboratories representing 30 (86%) countries. Participating laboratories included 36 (52%) national or regional reference labs and 33 (48%) lower-level laboratories. Most (94%) were public sector facilities and 71% reported existence of a national algorithm for syphilis testing in pregnancy, usually involving both treponemal and non-treponemal testing (72%). Less than half (41%) used rapid syphilis tests (RSTs); and only seven laboratories representing five countries reported RSTs were included in the national algorithm for pregnant women. Most (83%) laboratories serving ANCs reported using some type of QC system; 68% of laboratories reported participation in external QC. Only 36% of laboratories reported data to national/local surveillance. Half of all laboratories serving ANC settings reported a stockout of one or more essential supplies during the previous year (median duration, 30days). Updating laboratory algorithms, improving testing standards, integrating data into existing surveillance, and improved procurement and distribution of commodities may be needed to ensure elimination of MTCT of syphilis in the Americas. Copyright © 2015. Published by Elsevier Ireland Ltd.
Tracking progress toward global polio eradication, 2010-2011.
2012-04-20
In January 2012, polio eradication was declared a "programmatic emergency for global public health" by the Executive Board of the World Health Organization (WHO). Since the Global Polio Eradication Initiative (GPEI) began in 1988, progress has been tracked by surveillance of acute flaccid paralysis (AFP) cases and testing of linked stool specimens for polioviruses (PVs) in WHO-accredited Global Polio Laboratory Network (GPLN) laboratories, complemented by sewage testing (environmental surveillance) in selected areas. Monitoring AFP surveillance quality at national and subnational administrative levels using standard performance indicators identifies potential gaps where PV circulation might go undetected; monitoring specimen transport and laboratory reporting timeliness identifies areas where reporting delays could lead to late response, permitting ongoing transmission. This report provides an assessment of 2010-2011 performance indicators for AFP surveillance at national and subnational levels in polio-affected countries and laboratory reporting at the regional level, updated from 2009-2010. Overall, 16 (62%) of 26 countries with circulating wild PV (WPV) met national AFP surveillance indicator targets during both 2010 and 2011. All three countries with reestablished WPV transmission and 16 of 19 countries with WPV outbreaks had substantial proportions (>20%) of their respective populations living in areas with underperforming surveillance during 2010 or 2011. Targets for timely reporting of PV isolation and type characterization results were met in three of six WHO regions in 2010 and five regions in 2011. To achieve polio eradication, efforts are needed to improve AFP surveillance and laboratory performance.
Ye, Yuanyuan; Wang, Wei; Zhao, Haijian; He, Falin; Zhong, Kun; Yuan, Shuai; Wang, Zhiguo
2017-09-01
To investigate the situation of Internal Quality Control (IQC) practice for total cholesterol, triglycerides, HDL-cholesterol and LDL-cholesterol from 2014 to 2016 in laboratories in China and provide improvement measurements. A web-based External Quality Assessment (EQA) system was used to collect IQC data of lipid parameters in laboratories which continuously participated in the national EQA programs in China from 2014 to 2016. Pass rate of the coefficients of variation (CVs) of two level quality controls in four lipid parameters were calculated according to six quality specifications for precision to evaluate the current status of precision level of the four lipid parameters and their change over time in China. 533, 512, 504, and 466 laboratories continuously reported the data of level one for total cholesterol, triglyceride, HDL-cholesterol and LDL-cholesterol, and 212, 210, 208 and 198 laboratories reported the level two, respectively. The percentage of laboratories meeting the quality specification varied based on different criteria. Non-significant change can be found in the pass rate of CVs over time. The number of laboratories using a closed system increased over time, but still only accounted for a small proportion. There is no significant difference in the pass rate of CVs between closed and open systems. Triglycerides currently have a fairly good performance in China. While the performance of laboratories on total cholesterol, HDL-cholesterol and LDL-cholesterol has yet to be improved.
Project Laboratory for First-Year Students
ERIC Educational Resources Information Center
Planinsic, Gorazd
2007-01-01
This paper reports the modification of an existing experimental subject into a project laboratory for first-year physics students studying in the first cycle of university level and at a higher professional level. The subject is aimed at developing important science-related competences and skills through concrete steps under circumstances that are…
Naicker, Serisha D; Govender, Nevashan; Patel, Jaymati; Zietsman, Inge L; Wadula, Jeannette; Coovadia, Yacoob; Kularatne, Ranmini; Seetharam, Sharona; Govender, Nelesh P
2016-11-01
From February 2009 through August 2010, we compared species-level identification of bloodstream Candida isolates and susceptibility to fluconazole, voriconazole, and caspofungin between diagnostic and reference South African laboratories during national surveillance for candidemia. Diagnostic laboratories identified isolates to genus/species level and performed antifungal susceptibility testing, as indicated. At a reference laboratory, viable Candida isolates were identified to species-level using automated systems, biochemical tests, or DNA sequencing; broth dilution susceptibility testing was performed. Categorical agreement (CA) was calculated for susceptibility results of isolates with concordant species identification. Overall, 2172 incident cases were detected, 773 (36%) by surveillance audit. The Vitek 2 YST system (bioMérieux Inc, Marcy l'Etoile, France) was used for identification (360/863, 42%) and susceptibility testing (198/473, 42%) of a large proportion of isolates. For the five most common species (n = 1181), species-level identification was identical in the majority of cases (Candida albicans: 98% (507/517); Candida parapsilosis: 92% (450/488); Candida glabrata: 89% (89/100); Candida tropicalis: 91% (49/54), and Candida krusei: 86% (19/22)). However, diagnostic laboratories were significantly less likely to correctly identify Candida species other than C. albicans versus C. albicans (607/664, 91% vs. 507/517, 98%; P < .001). Susceptibility data were compared for isolates belonging to the five most common species and fluconazole, voriconazole, and caspofungin in 860, 580, and 99 cases, respectively. Diagnostic laboratories significantly under-reported fluconazole resistance in C. parapsilosis (225/393, 57% vs. 239/393, 61%; P < .001) but over-reported fluconazole non-susceptibility in C. albicans (36/362, 10% vs. 3/362, 0.8%; P < .001). Diagnostic laboratories were less likely to correctly identify Candida species other than C. albicans, under-reported fluconazole resistance for C. parapsilosis and over-reported fluconazole resistance for C. albicans. © The Author 2016. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Bartholomay, Roy C.; Edwards, Daniel D.; Campbell, Linford J.
1994-01-01
The U.S. Geological Survey and the Idaho Department of Water Resources, in response to a request from the U.S. Department of Energy, sampled 19 sites as part of a long-term project to monitor water quality of the Snake River Plain aquifer from the southern boundary of the Idaho National Engineering Laboratory to the Hagerman area. Water samples were collected and analyzed for selected radionuclides, stable isotopes, inorganic constituents, and organic compounds. The samples were collected from seven irrigation wells, four domestic wells, two springs, one stock well, three dairy wells, one observation well, and one commercial well. Two quality assurance samples also were collected and analyzed. None of the radionuclides, inorganic constituents, or organic compounds exceeded the established maximum contaminant levels for drinking water. Most of the radionuclide and inorganic constituent concen- trations exceeded their respective laboratory reporting levels. All samples analyzed for surfactants and dissolved organic carbon had concentrations that exceeded their reporting level. Ethylbenzene concentrations exceeded the reporting level in one water sample.
2014-09-01
Approved for public release; distribution is unlimited. Prepared for Geospatial Research Laboratory U.S. Army Engineer Research and Development...Center U.S. Army Corps of Engineers Under Data Level Enterprise Tools Monitored by Geospatial Research Laboratory 7701 Telegraph Road...Engineer Research and Development Center (ERDC) ERDC Geospatial Research Laboratory 7701 Telegraph Road 11. SPONSOR/MONITOR’S REPORT Alexandria, VA 22135
Introducing Students to Psychological Research: General Psychology as a Laboratory Course
ERIC Educational Resources Information Center
Thieman, Thomas J.; Clary, E. Gil; Olson, Andrea M.; Dauner, Rachel C.; Ring, Erin E.
2009-01-01
For 6 years, we have offered an integrated weekly laboratory focusing on research methods as part of our general psychology course. Through self-report measures and controlled comparisons, we found that laboratory projects significantly increase students' knowledge and comfort level with scientific approaches and concepts, sustain interest in…
Johnston, James D; Merrill, Ray M; Zimmerman, Grant C; Collingwood, Scott C; Reading, James C
2016-01-01
Biosafety level-2 laboratories are designated for work with human-derived samples or moderate-risk microorganisms that transmit primarily by direct contact exposures. Many laboratory procedures generate unseen droplets that contaminate workers' hands, equipment, and work surfaces. Workers' strict adherence to glove removal and handwashing is required prior to laboratory exit to prevent inadvertent transmission of pathogens to self or others. However, little is known about biosafety level-2 workers' compliance with these behaviors. In this article, glove removal and handwashing compliance upon laboratory exit were measured by direct observation of 93 biosafety level-2 research workers from 21 university laboratories. Participants completed a 41-item survey measuring social cognitive theory-based variables related to handwashing, self-reported compliance, and demographic factors. Survey items, observed exit frequency, and laboratory characteristics were evaluated for associations with handwashing compliance. Overall, observed glove removal and handwashing compliance upon laboratory exit were 43.0% (Standard Error [SE] = 2.3%), and 8.2% (SE = 1.2%), respectively, while workers' self-reported glove removal and handwashing compliance were 73.7% (SE = 3.6%) and 35.5% (SE = 4.1%), respectively. The average number of observed laboratory exits per hour was 2.8 for workers with any handwashing compliance vs. 5.4 for workers with no handwashing compliance (p = 0.0013). Among the cognitive variables, behavioral modeling by supervisors and coworkers had the strongest association with workers' compliance (slope = 3.5, SE = 1.3, p = 0.0113). Workers in laboratories with a written handwashing policy had higher compliance (Mean = 14.1%, SE = 5.9%) than workers in laboratories with no written policy (Mean = 1.1%, SE = 1.0%; p = 0.0488). Multi-faceted interventions that encourage modeling of the behavior by supervisors and coworkers, implementation of written handwashing policies, and efforts to reduce exit frequency by furnishing laboratories with necessary equipment and supplies may help improve compliance.
A comparison of two microscale laboratory reporting methods in a secondary chemistry classroom
NASA Astrophysics Data System (ADS)
Martinez, Lance Michael
This study attempted to determine if there was a difference between the laboratory achievement of students who used a modified reporting method and those who used traditional laboratory reporting. The study also determined the relationships between laboratory performance scores and the independent variables score on the Group Assessment of Logical Thinking (GALT) test, chronological age in months, gender, and ethnicity for each of the treatment groups. The study was conducted using 113 high school students who were enrolled in first-year general chemistry classes at Pueblo South High School in Colorado. The research design used was the quasi-experimental Nonequivalent Control Group Design. The statistical treatment consisted of the Multiple Regression Analysis and the Analysis of Covariance. Based on the GALT, students in the two groups were generally in the concrete and transitional stages of the Piagetian cognitive levels. The findings of the study revealed that the traditional and the modified methods of laboratory reporting did not have any effect on the laboratory performance outcome of the subjects. However, the students who used the traditional method of reporting showed a higher laboratory performance score when evaluation was conducted using the New Standards rubric recommended by the state. Multiple Regression Analysis revealed that there was a significant relationship between the criterion variable student laboratory performance outcome of individuals who employed traditional laboratory reporting methods and the composite set of predictor variables. On the contrary, there was no significant relationship between the criterion variable student laboratory performance outcome of individuals who employed modified laboratory reporting methods and the composite set of predictor variables.
McNulty, Cliodna A M; Verlander, Neville Q; Moore, Philippa C L; Larcombe, James; Dudley, Jan; Banerjee, Jaydip; Jadresic, Lyda
2015-09-01
The National Institute of Care Excellence (NICE) 2007 guidance CG54, on urinary tract infection (UTI) in children, states that clinicians should use urgent microscopy and culture as the preferred method for diagnosing UTI in the hospital setting for severe illness in children under 3 years old and from the GP setting in children under 3 years old with intermediate risk of severe illness. NICE also recommends that all 'infants and children with atypical UTI (including non-Escherichia coli infections) should have renal imaging after a first infection'. We surveyed all microbiology laboratories in England with Clinical Pathology Accreditation to determine standard operating procedures (SOPs) for urgent microscopy, culture and reporting of children's urine and to ascertain whether the SOPs facilitate compliance with NICE guidance. We undertook a computer search in six microbiology laboratories in south-west England to determine urine submissions and urine reports in children under 3 years. Seventy-three per cent of laboratories (110/150) participated. Enterobacteriaceae that were not E. coli were reported only as coliforms (rather than non-E. coli coliforms) by 61% (67/110) of laboratories. Eighty-eight per cent of laboratories (97/110) provided urgent microscopy for hospital and 54% for general practice (GP) paediatric urines; 61% of laboratories (confidence interval 52-70%) cultured 1 μl volume of urine, which equates to one colony if the bacterial load is 106 c.f.u. l(-1). Only 22% (24/110) of laboratories reported non-E. coli coliforms and provided urgent microscopy for both hospital and GP childhood urines; only three laboratories also cultured a 5 μl volume of urine. Only one of six laboratories in our submission audit had a significant increase in urine submissions and urines reported from children less than 3 years old between the predicted pre-2007 level in the absence of guidance and the 2008 level following publication of the NICE guidance. Less than a quarter of laboratories were providing a service that would allow clinicians to fully comply with the first line recommendations in the 2007 NICE UTI in children guidance. Laboratory urine submission report figures suggest that the guidance has not led to an increase in diagnosis of UTI in children under 3 years old.
Computerized Alerts Improve Outpatient Laboratory Monitoring of Transplant Patients
Staes, Catherine J.; Evans, R. Scott; Rocha, Beatriz H.S.C.; Sorensen, John B.; Huff, Stanley M.; Arata, Joan; Narus, Scott P.
2008-01-01
Authors evaluated the impact of computerized alerts on the quality of outpatient laboratory monitoring for transplant patients. For 356 outpatient liver transplant patients managed at LDS Hospital, Salt Lake City, this observational study compared traditional laboratory result reporting, using faxes and printouts, to computerized alerts implemented in 2004. Study alerts within the electronic health record notified clinicians of new results and overdue new orders for creatinine tests and immunosuppression drug levels. After implementing alerts, completeness of reporting increased from 66 to >99 %, as did positive predictive value that a report included new information (from 46 to >99 %). Timeliness of reporting and clinicians' responses improved after implementing alerts (p <0.001): median times for clinicians to receive and complete actions decreased to 9 hours from 33 hours using the prior traditional reporting system. Computerized alerts led to more efficient, complete, and timely management of laboratory information. PMID:18308982
O'Brien, Thomas F.; Stelling, John
2011-01-01
Summary: Microbial surveillance systems have varied in their source of support; type of laboratory reporting (patient care or reference); inclusiveness of reports filed; extent of microbial typing; whether single hospital, multihospital, or multicountry; proportion of total medical centers participating; and types, levels, integration across levels, and automation of analyses performed. These surveillance systems variably support the diagnosis and treatment of patients, local or regional infection control, local or national policies and guidelines, laboratory capacity building, sentinel surveillance, and patient safety. Overall, however, only a small fraction of available data are under any surveillance, and very few data are fully integrated and analyzed. Advancing informatics and genomics can make microbial surveillance far more efficient and effective at preventing infections and improving their outcomes. The world's microbiology laboratories should upload their reports each day to programs that detect events, trends, and epidemics in communities, hospitals, countries, and the world. PMID:21482726
1984-07-01
This report describes the historical records of the office of the Director of Navy Laboratories from 1960-1980. It lists the records down to the file...heading level and indexes them by chronological period, alphabetical file heading, and keyword. The report includes a brief administrative history of the office and organizational charts.
Under-reporting of sputum smear-positive tuberculosis cases in Kenya.
Tollefson, D; Ngari, F; Mwakala, M; Gethi, D; Kipruto, H; Cain, K; Bloss, E
2016-10-01
Although an estimated three million tuberculosis (TB) cases worldwide are missed by national TB programs annually, the level of under-reporting of diagnosed cases in high TB burden settings is largely unknown. To quantify and describe under-reporting of sputum smear-positive TB cases in Kenya. A national-level retrospective TB inventory study was conducted. All sputum smear-positive TB cases diagnosed by public or private laboratories during 1 April-30 June 2013 were extracted from laboratory registers in 73 randomly sampled subcounties and matched to TB cases in the national TB surveillance system (TIBU). Bivariate and multivariate analyses were conducted. In the subcounties sampled, 715 of 3409 smear-positive TB cases in laboratory registers were not found in TIBU. The estimated level of under-reporting of smear-positive TB cases in Kenya was 20.7% (95%CI 18.4-23.0). Under-reporting was greatest in subcounties with a high TB burden. Unreported cases were more likely to be patients aged ⩾55 years, have scanty smear results, and be diagnosed at large facilities, private facilities, and facilities in high TB burden regions. In Kenya, one fifth of smear-positive TB cases diagnosed during the study period went unreported, suggesting that the true TB burden is higher than reported. TB surveillance in Kenya should be strengthened to ensure all diagnosed TB cases are reported.
Survey of laboratory-acquired infections around the world in biosafety level 3 and 4 laboratories.
Wurtz, N; Papa, A; Hukic, M; Di Caro, A; Leparc-Goffart, I; Leroy, E; Landini, M P; Sekeyova, Z; Dumler, J S; Bădescu, D; Busquets, N; Calistri, A; Parolin, C; Palù, G; Christova, I; Maurin, M; La Scola, B; Raoult, D
2016-08-01
Laboratory-acquired infections due to a variety of bacteria, viruses, parasites, and fungi have been described over the last century, and laboratory workers are at risk of exposure to these infectious agents. However, reporting laboratory-associated infections has been largely voluntary, and there is no way to determine the real number of people involved or to know the precise risks for workers. In this study, an international survey based on volunteering was conducted in biosafety level 3 and 4 laboratories to determine the number of laboratory-acquired infections and the possible underlying causes of these contaminations. The analysis of the survey reveals that laboratory-acquired infections have been infrequent and even rare in recent years, and human errors represent a very high percentage of the cases. Today, most risks from biological hazards can be reduced through the use of appropriate procedures and techniques, containment devices and facilities, and the training of personnel.
The United States Environmental Protection Agency's (EPA) Office of Ground Water and Drinking Water (OGWDW) has developed a single-laboratory quantitation procedure: the lowest concentration minimum reporting level (LCMRL). The LCMRL is the lowest true concentration for which fu...
Chuntarut, A; Tientadakul, P; Wongkrajang, P
2016-06-01
The Thailand National External Quality Assessment Scheme (NEQAS) for blood coagulation was established in 2005. The objective of this study was to collect data of coagulation laboratory practices and satisfaction of NEQAS member. Two hundred seventy-six questionnaires were sent to laboratories that are members of NEQAS to obtain data relating to coagulation laboratory practice and satisfaction in 2014. Data from this survey were compared with data from the survey conducted in 2005 to evaluate levels of improvement. Of 276 questionnaires sent, 212 (76.8%) were returned. Improvements were characterized by the number of laboratories that (i) decreased use of 3.8% sodium citrate as anticoagulant; (ii) implemented use of at least two control levels for internal quality control; and (iii) implemented reporting of reference values with results, as well as establishing their own reference range and using geometric mean as the denominator for international normalized ratio calculation. For overall satisfaction, 179 of 206 (86.9%) participant laboratories reported being satisfied or very satisfied. Improvements in coagulation laboratory practices in Thailand were observed in every step of the total testing process. However, additional improvements are still needed, such as determination and use of a local reference range. © 2016 John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Finnegan, David Lawrence; Bowen, Scott Michael; Thompson, Joseph L.
This report is an update of report LA-13859-MS (Bowen et al., 2001). In that original report, the underground radionuclide inventory at the Nevada National Security Site (NNSS) was decay corrected to September 23, 1992, the date of the last underground nuclear test at the NNSS. In this report, the inventory is updated to account for the decay of radionuclides over two additional decades (1992-2012) and revised tritium, fission product and actinide inventory figures and tables are presented. The maximum contaminant levels for radionuclides were also updated to Safe Drinking Water Act Maximum Contaminant Levels (MCLs) (CFR, 2013). Also, a numbermore » of minor errata found in the original publication were corrected. An inventory of radionuclides produced by 828 underground nuclear tests conducted at the NNSS by the Lawrence Livermore National Laboratory, the Los Alamos National Laboratory, and the Department of the Defense from 1951 to 1992 includes tritium, fission products, actinides, and activation products. The inventory presented in this report provides an estimate of radioactivity remaining underground at the NNSS after nuclear testing. The original test inventory is decayed to September 30, 2012, and predictions of inventory decay over the subsequent 1000 years are presented. For the purposes of summary and publication, the Los Alamos National Laboratory and Lawrence Livermore National Laboratory authors of this report subdivided the inventory into five areas corresponding to the principal geographic test centers at the NNSS. The five areas roughly correspond to Underground Test Area “Corrective Action Units” (CAUs) for remediation of groundwater. In addition, the inventory is further subdivided for the Yucca Flat region by tests where the working point depth is more than 328 feet (100 meters) above the water table and tests that were detonated below that level. Water levels used were those from the U. S. Department of Energy, Nevada Operations Office (1997), now called the Nevada Field Office. Curie activities and atoms are reported as of September 30, 2012. This inventory is strictly a compilation of the residual radiologic inventory remaining from the underground nuclear tests conducted by Lawrence Livermore National Laboratory, Los Alamos National Laboratory and the Department of the Defense from 1951 to 1992 and does not include radioactivity from other types of nuclear testing (e.g., atmospheric, reactors, rocket engines). A companion classified report (Miller et al., 2002) contains test-specific data for each test performed at the NNSS. This work has been sponsored by the U. S. Department of Energy, National Nuclear Security Administration Nevada Field Office.« less
NASA Technical Reports Server (NTRS)
Greenbauer-Seng, L. A.
1983-01-01
The accurate determination of trace metals and fuels is an important requirement in much of the research into and development of alternative fuels for aerospace applications. Recognizing the detrimental effects of certain metals on fuel performance and fuel systems at the part per million and in some cases part per billion levels requires improved accuracy in determining these low concentration elements. Accurate analyses are also required to ensure interchangeability of analysis results between vendor, researcher, and end use for purposes of quality control. Previous interlaboratory studies have demonstrated the inability of different laboratories to agree on the results of metal analysis, particularly at low concentration levels, yet typically good precisions are reported within a laboratory. An interlaboratory study was designed to gain statistical information about the sources of variation in the reported concentrations. Five participant laboratories were used on a fee basis and were not informed of the purpose of the analyses. The effects of laboratory, analytical technique, concentration level, and ashing additive were studied in four fuel types for 20 elements of interest. The prescribed sample preparation schemes (variations of dry ashing) were used by all of the laboratories. The analytical data were statistically evaluated using a computer program for the analysis of variance technique.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1991-09-01
This report presents compiled information concerning a facility investigation of waste area group 6(WAG-6), of the solid waste management units (SWMU's) at Oak Ridge National Laboratory (ORNL). The WAG is a shallow ground disposal area for low-level radioactive wastes and chemical wastes. The report contains information on hydrogeological data, contaminant characterization, radionuclide concentrations, risk assessment and baseline human health evaluation including a toxicity assessment, and a baseline environmental evaluation.
Annual Site Environmental Report Calendar Year 2007
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dan Kayser-Ames Laboratory
This report summarizes the environmental status of Ames Laboratory for calendar year 2007. It includes descriptions of the Laboratory site, its mission, the status of its compliance with applicable environmental regulations, its planning and activities to maintain compliance, and a comprehensive review of its environmental protection, surveillance and monitoring activities. Ames Laboratory is located on the campus of Iowa State University (ISU) and occupies 11 buildings owned by the Department of Energy (DOE). See the Laboratory's Web page at www.external.ameslab.gov for locations and Laboratory overview. The Laboratory also leases space in ISU owned buildings. In 2007, the Laboratory accumulated andmore » disposed of waste under U.S. Environmental Protection Agency (EPA) issued generator numbers. All waste is handled according to all applicable EPA, State, Local and DOE Orders. In 2006 the Laboratory reduced its generator status from a Large Quantity Generator (LQG) to a Small Quantity Generator (SQG). EPA Region VII was notified of this change. The Laboratory's RCRA hazardous waste management program was inspected by EPA Region VII in April 2006. There were no notices of violations. The inspector was impressed with the improvements of the Laboratory's waste management program over the past ten years. The Laboratory was in compliance with all applicable federal, state, local and DOE regulations and orders in 2007. There were no radiological air emissions or exposures to the general public due to Laboratory activities in 2007. See U.S. Department of Energy Air Emissions Annual Report in Appendix B. As indicated in prior SERs, pollution awareness, waste minimization and recycling programs have been in practice since 1990, with improvements implemented most recently in 2003. Included in these efforts were battery and CRT recycling, waste white paper and green computer paper-recycling. Ames Laboratory also recycles/reuses salvageable metal, used oil, styrofoam peanuts, batteries, fluorescent lamps and telephone books. Ames Laboratory reported to DOE-Ames Site Office (AMSO), through the Laboratory's Self Assessment Report, on its Affirmative Procurement Performance Measure. A performance level of 'A' was achieved in 2007 for Integrated Safety, Health, and Environmental Protection. As reported in Site Environmental Reports for prior years, the Laboratory's Environmental Management System has been integrated into the Laboratory's Integrated Safety Management System since 2005. The integration of EMS into the way the Laboratory does business allows the Laboratory to systematically review, address and respond to the Laboratory's environmental impacts.« less
Environmental surveillance at Los Alamos during 1995
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-10-01
This report describes the environmental surveillance program at Los Alamos National Laboratory (LANL or the Laboratory) during 1995. The Laboratory routinely monitors for radiation and for radioactive and nonradioactive materials at (or on) Laboratory sites as well as in the surrounding region. LANL uses the monitoring result to determine compliance with appropriate standards and to identify potentially undesirable trends. Data were collected in 1995 to assess external penetrating radiation; quantities of airborne emissions and liquid effluents; concentrations of chemicals and radionuclides in ambient air, surface waters and groundwaters, municipal water supply, soils and sediments, and foodstuffs; and environmental compliance. Usingmore » comparisons with standards, regulations, and background levels, this report concludes that environmental effects from Laboratory operations are small and do not pose a demonstrable threat to the public, Laboratory employees, or the environment.« less
Verlander, Neville Q.; Moore, Philippa C. L.; Larcombe, James; Dudley, Jan; Banerjee, Jaydip; Jadresic, Lyda
2015-01-01
The National Institute of Care Excellence (NICE) 2007 guidance CG54, on urinary tract infection (UTI) in children, states that clinicians should use urgent microscopy and culture as the preferred method for diagnosing UTI in the hospital setting for severe illness in children under 3 years old and from the GP setting in children under 3 years old with intermediate risk of severe illness. NICE also recommends that all ‘infants and children with atypical UTI (including non-Escherichia coli infections) should have renal imaging after a first infection’. We surveyed all microbiology laboratories in England with Clinical Pathology Accreditation to determine standard operating procedures (SOPs) for urgent microscopy, culture and reporting of children's urine and to ascertain whether the SOPs facilitate compliance with NICE guidance. We undertook a computer search in six microbiology laboratories in south-west England to determine urine submissions and urine reports in children under 3 years. Seventy-three per cent of laboratories (110/150) participated. Enterobacteriaceae that were not E. coli were reported only as coliforms (rather than non-E. coli coliforms) by 61 % (67/110) of laboratories. Eighty-eight per cent of laboratories (97/110) provided urgent microscopy for hospital and 54 % for general practice (GP) paediatric urines; 61 % of laboratories (confidence interval 52–70 %) cultured 1 μl volume of urine, which equates to one colony if the bacterial load is 106 c.f.u. l− 1. Only 22 % (24/110) of laboratories reported non-E. coli coliforms and provided urgent microscopy for both hospital and GP childhood urines; only three laboratories also cultured a 5 μl volume of urine. Only one of six laboratories in our submission audit had a significant increase in urine submissions and urines reported from children less than 3 years old between the predicted pre-2007 level in the absence of guidance and the 2008 level following publication of the NICE guidance. Less than a quarter of laboratories were providing a service that would allow clinicians to fully comply with the first line recommendations in the 2007 NICE UTI in children guidance. Laboratory urine submission report figures suggest that the guidance has not led to an increase in diagnosis of UTI in children under 3 years old. PMID:26297550
Case Report: Clinically amyopathic dermatomyositis presenting acutely with isolated facial edema
Pappa, Efthymia; Gkeka, Marina; Protogerou, Asimina; Marinos, Leonidas; Loupa, Chariclia; Christopoulos, Constantinos
2018-01-01
A 45-year-old Asian man presented with acute-onset periorbital and facial edema associated with pyrexia. Muscle weakness was absent. Initial laboratory investigations showed an inflammatory reaction, while screening for infections was negative. Serum muscle enzyme levels were normal. He was hospitalized and treated empirically with antibiotics and corticosteroids, pending the result of facial skin and muscle biopsy. He showed a good clinical and laboratory response but an attempt to discontinue corticosteroids led to a prompt relapse of facial edema and pyrexia, associated with rising laboratory indices of inflammation. Biopsy findings were typical of dermatomyositis. Reintroduction of corticosteroid treatment resulted in complete clinical and laboratory remission. Facial edema as the sole clinical manifestation of dermatomyositis is extremely rare. There have been no previous reports of isolated facial edema in the setting of acute, clinically amyopathic dermatomyositis in adults. A high level of suspicion is required to make the diagnosis in the absence of myopathy and the hallmark cutaneous manifestations of the disease (heliotrope rash, Gottron papules). PMID:29707197
Environmental surveillance at Los Alamos during 1992
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kohen, K.; Stoker, A.; Stone, G.
1994-07-01
This report describes the environmental surveillance program at Los Alamos National Laboratory during 1992. The Laboratory routinely monitors for radiation and for radioactive and nonradioactive materials at (or on) Laboratory sites as well as in the surrounding region. LANL uses the monitoring results to determine compliance with appropriate standards and to identify potentially undesirable trends. Data were collected in 1992 to assess external penetrating radiation; quantities of airborne emissions and liquid effluents; concentrations of chemicals and radionuclides in ambient air, surface waters and groundwaters, municipal water supply, soils and sediments, and foodstuffs; and environmental compliance. Using comparisons with standards, regulations,more » and background levels, this report concludes that environmental effects from Laboratory operations are small and do not pose a demonstrable threat to the public, laboratory employees, or the environment.« less
Katz, Brian G.; Krulikas, Richard K.
1979-01-01
Water samples from wells in Nassau and Suffolk Counties were analyzed for chloride and nitrate. Two samples were collected at each well; one was analyzed by the U.S. Geological Survey, the other by a laboratory in the county from which the sample was taken. Results were compared statistically by paired-sample t-test to indicate the degree of uniformity among laboratory results. Chloride analyses from one of the three county laboratories differed significantly (0.95 confidence level) from that of a Geological Survey laboratory. For nitrate analyses, a significant difference (0.95 confidence level) was noted between results from two of the three county laboratories and the Geological Survey laboratory. The lack of uniformity among results reported by the participating laboratories indicates a need for continuing participation in a quality-assurance program and exercise of strong quality control from time of sample collection through analysis so that differences can be evaluated. (Kosco-USGS)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Virginia Finley
The results of the 1999 environmental surveillance and monitoring program for the Princeton Plasma Physics Laboratory (PPPL) are presented and discussed. The purpose of this report is to provide the U.S. Department of Energy and the public with information on the level of radioactive and non-radioactive pollutants (if any) that are added to the environment as a result of PPPL's operations. The report also summarizes environmental initiatives, assessments, and programs that were undertaken in 1999. The Princeton Plasma Physics Laboratory has engaged in fusion energy research since 1951. The long-range goal of the U.S. Magnetic Fusion Energy Research Program ismore » to create innovations to make fusion power a practical reality--an alternative energy source. 1999 marked the first year of National Spherical Torus Experiment (NSTX) operations and Tokamak Fusion Test Reactor (TFTR) dismantlement and deconstruction activities. A collaboration among fourteen national laboratories, universities, and research institutions, the NSTX is a major element in the U.S. Fusion Energy Sciences Program. It has been designed to test the physics principles of spherical torus (ST) plasmas. The ST concept could play an important role in the development of smaller, more economical fusion reactors. With its completion within budget and ahead of its target schedule, NSTX first plasma occurred on February 12, 1999. The 1999 performance of the Princeton Plasma Physics Laboratory was rated ''outstanding'' by the U.S. Department of Energy in the Laboratory Appraisal report issued early in 2000. The report cited the Laboratory's consistently excellent scientific and technological achievements, its successful management practices, and included high marks in a host of other areas including environmental management, employee health and safety, human resources administration, science education, and communications. Groundwater investigations continued under a voluntary agreement with the New Jersey Department of Environmental Protection. PPPL monitored for the presence of non-radiological contaminants, mainly volatile organic compounds (components of degreasing solvents). Monitoring revealed the presence of low levels of volatile organic compounds in an area adjacent to PPPL. Also, PPPL's radiological monitoring program characterized the ambient, background levels of tritium in the environment and from the TFTR stack; the data are presented in this report.« less
[30 years since the first AIDS cases were reported: history and the present part III].
Brůčková, Marie
2012-12-01
The end of the article features the development of HIV/AIDS diagnosis and its implementation in the Czech Republic. The establishment of the National Reference Laboratory for AIDS (NRL AIDS) at the National Institute of Public Health late in 1985 is mentioned and its responsibilities as the methodology centre in the areas of HIV/AIDS laboratory diagnosis and epidemiology are specified. In cooperation with the respective experts, a pilot HIV/AIDS prevalence study was conducted in the Czech Republic. The general criteria for HIV/AIDS laboratory diagnosis were set for both blood transfusion service and microbiology laboratories. Early in 1987, mass screening of blood donors was introduced in blood transfusion centres and in the second half of the same year, the HIV screening program was extended to selected microbiology laboratories. The NRL AIDS established a unified data reporting system, analyzed the results at the national level, and since 1989, has been reporting the outcomes to the international AIDS, and later HIV/AIDS, reporting system. The NRL AIDS also participated in a number of international projects in the areas of the research and development of laboratory techniques and epidemiological surveillance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lumetta, C.C.; Park, J.F.
1994-03-01
This report summarizes FY 1993 progress in biological and general life sciences research programs conducted for the Department of Energy`s Office of Health and Environmental REsearch (OHER) at Pacific Northwest Laboratory (PNL). This research provides knowledge of fundamental principles necessary to identify, understand, and anticipate the long-term health consequences of exposure to energy-related radiation and chemicals. The Biological Research section contains reports of studies using laboratory animals, in vitro cell systems, and molecular biological systems. This research includes studies of the impact of radiation, radionuclides, and chemicals on biological responses at all levels of biological organization. The General Life Sciencesmore » Research section reports research conducted for the OHER human genome program.« less
Pancreatitis with normal lipase and amylase in setting of end-stage renal disease.
Sharma, Anuj; Masood, Umair; Khan, Babar; Chawla, Kunal; Manocha, Divey
2017-09-01
Pancreatitis with normal lipase and amylase level is a rare phenomenon. This is especially true in patient with end-stage renal disease as lipase and amylase are renally excreted. Literature review reveals previous case report of pancreatitis with normal lipase and amylase level, however, none of them occurred in the setting of end-stage renal disease. Our case is the first such reported case of pancreatitis in such setting. Here we report a 30year old male with past medical history of end-stage renal disease who presented in emergency department with acute abdominal pain. Laboratory work up revealed normal lipase and amylase level. However, radiological work up was consistent with pancreatitis. This case report highlight the importance of taking the overall clinical picture rather than laboratory work up to rule in or rule out the diagnosis of pancreatitis. Furthermore, this should also serve an important reminder for clinicians to further investigate where clinical suspicion for pancreatitis is high. Copyright © 2017 Elsevier Inc. All rights reserved.
Derived concentration guideline levels for Argonne National Laboratory's building 310 area.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kamboj, S., Dr.; Yu, C ., Dr.
2011-08-12
The derived concentration guideline level (DCGL) is the allowable residual radionuclide concentration that can remain in soil after remediation of the site without radiological restrictions on the use of the site. It is sometimes called the single radionuclide soil guideline or the soil cleanup criteria. This report documents the methodology, scenarios, and parameters used in the analysis to support establishing radionuclide DCGLs for Argonne National Laboratory's Building 310 area.
Mlynash, Michael; Buckwalter, Marion S; Okada, Ami; Caulfield, Anna Finley; Venkatasubramanian, Chitra; Eyngorn, Irina; Verbeek, Marcel M; Wijman, Christine A C
2013-10-01
In comatose post-cardiac arrest patients, a serum neuron-specific enolase (NSE) level of >33 μg/L within 72 h was identified as a reliable marker for poor outcome in a large Dutch study (PROPAC), and this level was subsequently adopted in an American Academy of Neurology practice parameter. Later studies reported that NSE >33 μg/L is not a reliable predictor of poor prognosis. To test whether different clinical laboratories contribute to this variability, we compared NSE levels from the laboratory used in the PROPAC study (DLM-Nijmegen) with those of our hospital's laboratory (ARUP) using paired blood samples. We prospectively enrolled cardiac arrest patients who remained comatose after resuscitation. During the first 3 days, paired blood samples for serum NSE were drawn at a median of 10 min apart. After standard preparation for each lab, one sample was sent to ARUP laboratories and the other to DLM-Nijmegen. Fifty-four paired serum samples from 33 patients were included. Although the serum NSE measurements correlated well between laboratories (R = 0.91), the results from ARUP were approximately 30% lower than those from DLM-Nijmegen. Therapeutic hypothermia did not affect this relationship. Two patients had favorable outcomes after hypothermia despite NSE levels measured by DLM-Nijmegen as >33 μg/L. Absolute serum NSE levels of comatose cardiac arrest patients differ between laboratories. Any specific absolute cut-off levels proposed to prognosticate poor outcome should not be used without detailed data on how neurologic outcomes correspond to a particular laboratory's method, and even then only in conjunction with other prognostic variables.
Macy, Jamie P.; Monroe, Stephen A.
2006-01-01
The National Park Service initiated a Level 1 Water-Quality Inventory program to provide water-quality data to park managers so informed natural resource management decisions could be made. Level 1 water-quality data were collected by the U.S. Geological Survey Arizona Water Science Center at 57 sites in 13 National Park units located in the Southern Colorado Plateau Inventory and Monitoring network in water years 2005 and 2006. These data describe the current water-quality at selected sites within the park units and provide information for monitoring future trends. Water samples were collected three times at each type of site including wells, springs, seeps, tinajas, rivers, a lake, and an irrigation ditch. Field measurements were taken at each site and they included pH, specific conductance, temperature, barometric pressure, dissolved oxygen, alkalinity, turbidity, and discharge rates where applicable. Water samples collected were sent to the U.S. Geological Survey National Water Quality Laboratory and analyzed for major ions, trace elements, and nutrients. The National Water Quality Laboratory also analyzed selected samples for mercury and petroleum hydrocarbons. Additional samples at selected sites were collected and analyzed for cyanide, radiochemistry, and suspended sediment by U.S. Geological Survey contract labs. Fecal-indicator bacteria (Escherichia coli) were sampled for at selected sites as another indicator of water quality. Quality control for this study was achieved through proper training of field personnel, use of standard U.S. Geological Survey field and laboratory protocols, collection of sample blanks and replicates, and a thorough review of the water-quality analyses. Measured field pH ranged from 6.0 to 8.8, within normal range for springs and rivers, at most sites. Concentrations of dissolved solids ranged from 48 to 8,680 mg/L and the majority of samples had concentrations of dissolved solids below 900 mg/L. Trace-element concentrations at most sites were at or near the laboratory reporting levels. The highest overall trace-element concentrations were found at U.S. Highway 160 Spring near Park Entrance to Mesa Verde National Park. Concentrations of uranium in samples at all sites ranged from below the detection limit to 55.7 ?g/L. Water samples from selected sites were analyzed for total petroleum hydrocarbons and concentrations of total petroleum hydrocarbons were at or above the laboratory detection limit in samples at six National Park units. Ten sites were sampled for Escherichia coli and positive counts were found at 9 out of the ten sites, the highest colony counts were found at Chinle Creek at Chinle, AZ in Canyon de Chelly National Monument. Measured concentrations of dissolved ammonia, nitrite, and nitrate were at or near laboratory reporting levels at most sites; nitrate concentrations ranged from below the reporting limit (0.047 mg/L) to 9.77 mg/L. Samples that were analyzed for mercury had concentrations below or at the laboratory reporting level. Concentrations of cyanide were less than the laboratory reporting level for all samples except two, Spruce Tree House Spring in Mesa Verde National Park and Pine Tree Canyon Tinaja in Canyon de Chelly National Monument, which had average concentrations of .042 and .011 ?g/L respectively. Gross alpha/beta radioactivity counts were below the U.S. Environmental Protection Agency maximum contaminant level except for samples from Casa Chiquita Well Middle at Chaco Culture National Historical Park which averaged 35 pCi/L. Suspended-sediment concentrations were variable and ranged from 10 to 150,000 mg/L.
Shoda, Megan E.; Nowell, Lisa H.; Stone, Wesley W.; Sandstrom, Mark W.; Bexfield, Laura M.
2018-04-02
In 2013, the U.S. Geological Survey National Water Quality Laboratory (NWQL) made a new method available for the analysis of pesticides in filtered water samples: laboratory schedule 2437. Schedule 2437 is an improvement on previous analytical methods because it determines the concentrations of 225 fungicides, herbicides, insecticides, and associated degradates in one method at similar or lower concentrations than previously available methods. Additionally, the pesticides included in schedule 2437 were strategically identified in a prioritization analysis that assessed likelihood of occurrence, prevalence of use, and potential toxicity. When the NWQL reports pesticide concentrations for analytes in schedule 2437, the laboratory also provides supplemental information useful to data users for assessing method performance and understanding data quality. That supplemental information is discussed in this report, along with an initial analysis of analytical recovery of pesticides in water-quality samples analyzed by schedule 2437 during 2013–2015. A total of 523 field matrix spike samples and their paired environmental samples and 277 laboratory reagent spike samples were analyzed for this report (1,323 samples total). These samples were collected in the field as part of the U.S. Geological Survey National Water-Quality Assessment groundwater and surface-water studies and as part of the NWQL quality-control program. This report reviews how pesticide samples are processed by the NWQL, addresses how to obtain all the data necessary to interpret pesticide concentrations, explains the circumstances that result in a reporting level change or the occurrence of a raised reporting level, and describes the calculation and assessment of recovery. This report also discusses reasons why a data user might choose to exclude data in an interpretive analysis and outlines the approach used to identify the potential for decreased data quality in the assessment of method recovery. The information provided in this report is essential to understanding pesticide data determined by schedule 2437 and should be reviewed before interpretation of these data.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1991-09-01
This report presents compiled information concerning a facility investigation of waste area group 6(WAG-6), of the solid waste management units (SWMU'S) at Oak Ridge National Laboratory (ORNL). The WAG is a shallow ground disposal area for low-level radioactive wastes and chemical wastes. The report contains information on hydrogeological data, contaminant characterization, radionuclide concentrations, risk assessment from doses to humans and animals and associated cancer risks, exposure via food chains, and historical data. (CBS)
Students' Experience in a General Chemistry Cooperative Problem Based Laboratory
ERIC Educational Resources Information Center
Sandi-Urena, Santiago; Cooper, Melanie M.; Gatlin, Todd A.; Bhattacharyya, Gautam
2011-01-01
Most educators and scientists would agree that science laboratory instruction has the potential of developing science practices fundamental to achieving scientific literacy. However, there is scant evidence to support that this potential is realized, particularly in tertiary level education. This paper reports qualitative results from a sequential…
Students' motivation toward laboratory work in physiology teaching.
Dohn, Niels Bonderup; Fago, Angela; Overgaard, Johannes; Madsen, Peter Teglberg; Malte, Hans
2016-09-01
The laboratory has been given a central role in physiology education, and teachers report that it is motivating for students to undertake experimental work on live animals or measuring physiological responses on the students themselves. Since motivation is a critical variable for academic learning and achievement, then we must concern ourselves with questions that examine how students engage in laboratory work and persist at such activities. The purpose of the present study was to investigate how laboratory work influences student motivation in physiology. We administered the Lab Motivation Scale to assess our students' levels of interest, willingness to engage (effort), and confidence in understanding (self-efficacy). We also asked students about the role of laboratory work for their own learning and their experience in the physiology laboratory. Our results documented high levels of interest, effort, and self-efficacy among the students. Correlation analyses were performed on the three motivation scales and exam results, yet a significant correlation was only found between self-efficacy in laboratory work and academic performance at the final exam. However, almost all students reported that laboratory work was very important for learning difficult concepts and physiological processes (e.g., action potential), as the hands-on experiences gave a more concrete idea of the learning content and made the content easier to remember. These results have implications for classroom practice as biology students find laboratory exercises highly motivating, despite their different personal interests and subject preferences. This highlights the importance of not replacing laboratory work by other nonpractical approaches, for example, video demonstrations or computer simulations. Copyright © 2016 The American Physiological Society.
Rosin, P; Niskanen, T; Palm, D; Struelens, M; Takkinen, J
2013-06-20
A hybrid strain of enteroaggregative and Shiga toxin 2-producing Escherichia coli (EAEC-STEC) serotype O104:H4 strain caused a large outbreak of haemolytic uraemic syndrome and bloody diarrhoea in 2011 in Europe. Two surveys were performed in the European Union (EU) and European Economic Area (EEA) countries to assess their laboratory capabilities to detect and characterise this previously uncommon STEC strain. Prior to the outbreak, 11 of the 32 countries in this survey had capacity at national reference laboratory (NRL) level for epidemic case confirmation according to the EU definition. During the outbreak, at primary diagnostic level, nine countries reported that clinical microbiology laboratories routinely used Shiga toxin detection assays suitable for diagnosis of infections with EAEC-STEC O104:H4, while 14 countries had NRL capacity to confirm epidemic cases. Six months after the outbreak, 22 countries reported NRL capacity to confirm such cases following initiatives taken by NRLs and the European Centre for Disease Prevention and Control (ECDC) Food- and Waterborne Disease and Zoonoses laboratory network. These data highlight the challenge of detection and confirmation of epidemic infections caused by atypical STEC strains and the benefits of coordinated EU laboratory networks to strengthen capabilities in response to a major outbreak.
A laboratory evaluation of modified asphalt : final report.
DOT National Transportation Integrated Search
1981-01-01
Quality aggregate availability in southern Louisiana has reached an alarmingly low level, while naturally occurring materials (sands) have been ignored due to their poor structural properties. Recent research reported by Chem-Crete Corporation indica...
Nuclear waste management. Semiannual progress report, October 1982-March 1983
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chikalla, T.D.; Powell, J.A.
1983-06-01
This document is one of a series of technical progress reports designed to report radioactive waste management programs at the Pacific Northwest Laboratory. Accomplishments in the following programs are reported: waste stabilization; Materials Characterization Center; waste isolation; low-level waste management; remedial action; and supporting studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fresquez, Philip R.
Field mice are effective indicators of contaminant presence. This paper reports the concentrations of various radionuclides, heavy metals, polychlorinated biphenyls, high explosives, perchlorate, and dioxin/furans in field mice (mostly deer mice) collected from regional background areas in northern New Mexico. These data, represented as the regional statistical reference level (the mean plus three standard deviations = 99% confidence level), are used to compare with data from field mice collected from areas potentially impacted by Laboratory operations, as per the Environmental Surveillance Program at Los Alamos National Laboratory.
Health-hazard-evaluation report HETA 87-387-2050, Ithaca College, Ithaca, New York
DOE Office of Scientific and Technical Information (OSTI.GOV)
Almaguer, D.; Klein, M.; Klincewicz, S.
1990-06-01
In response to a request from an authorized representative of the employees of Ithaca College located in Ithaca, New York, a study was made of possible hazardous conditions at the college stemming from the use of formalin solutions during the embalming and fixing of primates for study. Samples were collected in the anatomy laboratory, the refrigeration room, and the hallway which separated the two rooms. Analyses of the 22 samples collected ranged from nondetectable to 0.12 parts per million for formaldehyde. Two samples which contained quantifiable levels of formaldehyde were collected in the anatomy laboratory. All tests for phenol andmore » ethylene-glycol showed nondetectable levels. Measurements indicated the ventilation system supplied air to the location in line with requirements but that air distribution and exhaust within the laboratory were not conducive to minimizing occupant exposure to contaminants. Only one set of exhaust conditions was under negative pressure. Ventilation may have been inadequate. The staff reported symptoms of headache, sinus congestion, odors in the office, sore throat, and itching and burning eyes. The authors conclude that exposures to low levels of formaldehyde existed at the time of the survey. Formaldehyde levels measured during the study were not deemed high enough to be causing reported symptoms. The authors recommend measures to improve the ventilation system.« less
Kohlmann, Rebekka; Gatermann, Sören G
2016-01-01
Many clinical microbiology laboratories report on cumulative antimicrobial susceptibility testing (cAST) data on a regular basis. Criteria for generation of cAST reports, however, are often obscure and inconsistent. Whereas the CLSI has published a guideline for analysis and presentation of cAST data, national guidelines directed at clinical microbiology laboratories are not available in Europe. Thus, we sought to describe the influence of different parameters in the process of cAST data analysis in the setting of a German routine clinical microbiology laboratory during 2 consecutive years. We developed various program scripts to assess the consequences ensuing from different algorithms for calculation of cumulative antibiograms from the data collected in our clinical microbiology laboratory in 2013 and 2014. One of the most pronounced effects was caused by exclusion of screening cultures for multi-drug resistant organisms which decreased the MRSA rate in some cases to one third. Dependent on the handling of duplicate isolates, i.e. isolates of the same species recovered from successive cultures on the same patient during the time period analyzed, we recorded differences in resistance rates of up to 5 percentage points for S. aureus, E. coli and K. pneumoniae and up to 10 percentage points for P. aeruginosa. Stratification by site of care and specimen type, testing of antimicrobials selectively on resistant isolates, change of interpretation rules and analysis at genus level instead of species level resulted in further changes of calculated antimicrobial resistance rates. The choice of parameters for cAST data analysis may have a substantial influence on calculated antimicrobial resistance rates. Consequently, comparability of cAST reports from different clinical microbiology laboratories may be limited. We suggest that laboratories communicate the strategy used for cAST data analysis as long as national guidelines for standardized cAST data analysis and reporting do not exist in Europe.
Tyrrell, Frances; Stafford, Cortney; Yakrus, Mitchell; Youngblood, Monica; Hill, Andrew; Johnston, Stephanie
We investigated data from US public health laboratories funded through the Centers for Disease Control and Prevention's Tuberculosis Elimination and Laboratory Cooperative Agreement to document trends and challenges in meeting national objectives in tuberculosis (TB) laboratory diagnoses. We examined data on workload and turnaround time from public health laboratories' progress reports during 2009-2013. We reviewed methodologies, laboratory roles, and progress toward rapid detection of Mycobacterium tuberculosis complex through nucleic acid amplification (NAA) testing. We compared selected data with TB surveillance reports to estimate public health laboratories' contribution to national diagnostic services. During the study period, culture and drug susceptibility tests decreased, but NAA testing increased. Public health laboratories achieved turnaround time benchmarks for drug susceptibility tests at lower levels than for acid-fast bacilli smear and identification from culture. NAA positivity in laboratories among surveillance-reported culture-positive TB cases increased from 26.6% (2355 of 8876) in 2009 to 40.0% (2948 of 7358) in 2013. Public health laboratories provided an estimated 50.9% (4285 of 8413 in 2010) to 57.2% (4210 of 7358 in 2013) of culture testing and 88.3% (6822 of 7727 in 2011) to 94.4% (6845 of 7250 in 2012) of drug susceptibility tests for all US TB cases. Public health laboratories contribute substantially to TB diagnoses in the United States. Although testing volumes mostly decreased, the increase in NAA testing indicates continued progress in rapid M tuberculosis complex detection.
Laboratory and Self-Report Methods to Assess Reappraisal and Distraction in Youth.
Bettis, Alexandra H; Henry, Lauren; Prussien, Kemar V; Vreeland, Allison; Smith, Michele; Adery, Laura H; Compas, Bruce E
2018-06-07
Coping and emotion regulation are central features of risk and resilience in childhood and adolescence, but research on these constructs has relied on different methods of assessment. The current study aimed to bridge the gap between questionnaire and experimental methods of measuring secondary control coping strategies, specifically distraction and cognitive reappraisal, and examine associations with symptoms of anxiety and depression in youth. A community sample of 70 youth (ages 9-15) completed a novel experimental coping and emotion regulation paradigm and self-report measures of coping and emotion regulation and symptoms. Findings indicate that use of distraction and reappraisal during the laboratory paradigm was associated with lower levels of negative emotion during the task. Youth emotion ratings while implementing distraction, but not reappraisal, during the laboratory task were associated with youth self-reported use of secondary control coping in response to family stress. Youth symptoms of anxiety and depression were also significantly positively associated with negative emotion ratings during the laboratory task, and both laboratory task and self-reported coping and emotion regulation accounted for significant variance in symptoms in youth. Both questionnaire and laboratory methods to assess coping and emotion regulation in youth are important for understanding these processes as possible mechanisms of risk and resilience and continued integration of these methods is a priority for future research.
ERIC Educational Resources Information Center
Chen, Shuming
2018-01-01
An undergraduate organic chemistry laboratory experiment that provides an introduction to the concepts and practices of photoredox catalysis is reported. While undergraduate-level photochemistry experiments typically place emphasis on analytical properties of catalysts rather than synthetic applications, this experiment showcases the power and…
Clinical Laboratory Sciences Discipline Advisory Group Final Report. Kentucky Allied Health Project.
ERIC Educational Resources Information Center
Kentucky Council on Public Higher Education, Frankfort.
Education in the clinical laboratory sciences in Kentucky and articulation within the field are examined, based on the Kentucky Allied Health Project (KAHP), which designed an articulated statewide system to promote entry and exit of personnel at a variety of educational levels. The KAHP model promotes articulation in learning, planning, and…
Howanitz, Peter J; Lehman, Christopher M; Jones, Bruce A; Meier, Frederick A; Horowitz, Gary L
2015-08-01
Hemolysis is an important clinical laboratory quality attribute that influences result reliability. To determine hemolysis identification and rejection practices occurring in clinical laboratories. We used the College of American Pathologists Survey program to distribute a Q-Probes-type questionnaire about hemolysis practices to Chemistry Survey participants. Of 3495 participants sent the questionnaire, 846 (24%) responded. In 71% of 772 laboratories, the hemolysis rate was less than 3.0%, whereas in 5%, it was 6.0% or greater. A visual scale, an instrument scale, and combination of visual and instrument scales were used to identify hemolysis in 48%, 11%, and 41% of laboratories, respectively. A picture of the hemolysis level was used as an aid to technologists' visual interpretation of hemolysis levels in 40% of laboratories. In 7.0% of laboratories, all hemolyzed specimens were rejected; in 4% of laboratories, no hemolyzed specimens were rejected; and in 88% of laboratories, some specimens were rejected depending on hemolysis levels. Participants used 69 different terms to describe hemolysis scales, with 21 terms used in more than 10 laboratories. Slight and moderate were the terms used most commonly. Of 16 different cutoffs used to reject hemolyzed specimens, moderate was the most common, occurring in 30% of laboratories. For whole blood electrolyte measurements performed in 86 laboratories, 57% did not evaluate the presence of hemolysis, but for those that did, the most common practice in 21 laboratories (24%) was centrifuging and visually determining the presence of hemolysis in all specimens. Hemolysis practices vary widely. Standard assessment and consistent reporting are the first steps in reducing interlaboratory variability among results.
Glass, Leila; Graham, Diana M.; Deweese, Benjamin N.; Jones, Kenneth Lyons; Riley, Edward P.; Mattson, Sarah N.
2014-01-01
Clinical research and practice support a multi-method approach to validating behavioral problems in children. We examined whether parent-reported symptoms of hyperactivity and inattention (using the Disruptive Behavior Disorder Rating Scale) were substantiated by objective laboratory measures [hyperactivity measured by wrist-worn actigraphy (ACT) and inattention assessed using a 20-minute continuous performance task (CPT)] in three age- and demographically-matched groups of school-age children: children with prenatal alcohol exposure (AE), non-exposed children with idiopathic ADHD (ADHD), and controls (CON). Results indicated that the clinical groups (AE, ADHD) had significantly higher parent-reported levels for both domains compared to the CON group, and did not differ from each other. On the laboratory measures, the clinical groups were more inattentive than controls on the CPT, but did not differ from each other. In contrast, the ADHD group had higher objective activity on the ACT than AE and CON, which did not differ from each other. Thus, laboratory measures differentially validated parent reports in a group-dependent manner. Actigraphy substantiated parent-reported hyperactivity for children in the ADHD group but not for children in the AE group, while the CPT validated parent-reported inattention for both clinical groups. Although the majority of children in the AE group met criteria for ADHD, objective activity levels were not different from controls, indicating that hyperactivity may be a less prominent feature in the AE group. Thus, while there is considerable overlap between the effects of prenatal alcohol exposure and ADHD, differences in behavioral profiles may be clinically useful in differential diagnosis. Further, these data indicate that objective measures should be used to validate parent reports. PMID:24512965
Tank 30 and 37 Supernatant Sample Cross-Check and Evaporator Feed Qualification Analysis-2012
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oji, L. N.
2013-03-07
This report summarizes the analytical data reported by the F/H and Savannah River National Laboratories for the 2012 cross-check analysis for high level waste supernatant liquid samples from SRS Tanks 30 and 37. The intent of this Tank 30 and 37 sample analyses was to perform cross-checks against routine F/H Laboratory analyses (corrosion and evaporator feed qualification programs) using samples collected at the same time from both tanks as well as split samples from the tanks.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neupauer, R.M.; Thurmond, S.M.
This report contains health and safety information relating to the chemicals that have been identified in the mixed waste streams at the Waste Treatment Facility at the Idaho National Engineering Laboratory. Information is summarized in two summary sections--one for health considerations and one for safety considerations. Detailed health and safety information is presented in material safety data sheets (MSDSs) for each chemical.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neupauer, R.M.; Thurmond, S.M.
This report contains health and safety information relating to the chemicals that have been identified in the mixed waste streams at the Waste Treatment Facility at the Idaho National Engineering Laboratory. Information is summarized in two summary sections--one for health considerations and one for safety considerations. Detailed health and safety information is presented in material safety data sheets (MSDSs) for each chemical.
Screening-Level Ecological Risk Assessment Methods, Revision 3
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mirenda, Richard J.
2012-08-16
This document provides guidance for screening-level assessments of potential adverse impacts to ecological resources from release of environmental contaminants at the Los Alamos National Laboratory (LANL or the Laboratory). The methods presented are based on two objectives, namely: to provide a basis for reaching consensus with regulators, managers, and other interested parties on how to conduct screening-level ecological risk investigations at the Laboratory; and to provide guidance for ecological risk assessors under the Environmental Programs (EP) Directorate. This guidance promotes consistency, rigor, and defensibility in ecological screening investigations and in reporting those investigation results. The purpose of the screening assessmentmore » is to provide information to the risk managers so informed riskmanagement decisions can be made. This document provides examples of recommendations and possible risk-management strategies.« less
Open-source LIMS in Vietnam: The path toward sustainability and host country ownership.
Landgraf, Kenneth M; Kakkar, Reshma; Meigs, Michelle; Jankauskas, Paul T; Phan, Thi Thu Huong; Nguyen, Viet Nga; Nguyen, Duy Thai; Duong, Thanh Tung; Nguyen, Thi Hoa; Bond, Kyle B
2016-09-01
The objectives of this case report are as follows: to describe the process of establishing a national laboratory information management system (LIMS) program for clinical and public health laboratories in Vietnam; to evaluate the outcomes and lessons learned; and to present a model for sustainability based on the program outcomes that could be applied to diverse laboratory programs. This case report comprises a review of program documentation and records, including planning and budgetary records of the donor, monthly reports from the implementer, direct observation, and ad-hoc field reports from technical advisors and governmental agencies. Additional data on program efficacy and user acceptance were collected from routine monitoring of laboratory policies and operational practices. LIMS software was implemented at 38 hospital, public health and HIV testing laboratories in Vietnam. This LIMS was accepted by users and program managers as a useful tool to support laboratory processes. Implementation cost per laboratory and average duration of deployment decreased over time, and project stakeholders initiated transition of financing (from the donor to local institutions) and of system maintenance functions (from the implementer to governmental and site-level staff). Collaboration between the implementer in Vietnam and the global LIMS user community was strongly established, and knowledge was successfully transferred to staff within Vietnam. Implementing open-sourced LIMS with local development and support was a feasible approach towards establishing a sustainable laboratory informatics program that met the needs of health laboratories in Vietnam. Further effort to institutionalize IT support capacity within key government agencies is ongoing. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Princeton Plasma Physics Laboratory Annual Site Environmental Report for Calendar Year 1998
DOE Office of Scientific and Technical Information (OSTI.GOV)
V. Finley
2000-03-06
The results of the 1998 environmental surveillance and monitoring program for the Princeton Plasma Physics Laboratory (PPPL) are presented and discussed. The purpose of this report is to provide the US Department of Energy and the public with information on the level of radioactive and non-radioactive pollutants, if any, that are added to the environment as a result of PPPL's operations. The report also summarizes environmental initiatives, assessments, and programs that were undertaken in 1998. One significant initiative is the Integrated Safety Management (ISM) program that embraces environment, safety, and health principles as one.
Prostate needle biopsy processing: a survey of laboratory practice across Europe.
Varma, Murali; Berney, Daniel M; Algaba, Ferran; Camparo, Philippe; Compérat, Eva; Griffiths, David F R; Kristiansen, Glen; Lopez-Beltran, Antonio; Montironi, Rodolfo; Egevad, Lars
2013-02-01
To determine the degree of variation in the handling of prostate needle biopsies (PBNx) in laboratories across Europe. A web based survey was emailed to members of the European Network of Uropathology and the British Association of Urological Pathologists. Responses were received from 241 laboratories in 15 countries. PNBx were generally taken by urologists (93.8%) or radiologists (23.7%) but in 8.7% were also taken by non-medical personnel such as radiographers, nurses or biomedical assistants. Of the responding laboratories, 40.8% received cores in separate containers, 42.3% processed one core/block, 54.2% examined three levels/block, 49.4% examined one H&E section/level and 56.1% retained spare sections for potential immunohistochemistry. Of the laboratories, 40.9% retained unstained spares for over a year while 36.2% discarded spares within 1 month of reporting. Only two (0.8%) respondents routinely performed immunohistochemistry on all PNBx. There were differences in laboratory practice between the UK and the rest of Europe (RE). Procurement of PNBx by non-medical personnel was more common in the UK. RE laboratories more commonly received each core in a separate container, processed one core/block, examined fewer levels/block and examined more H&E sections/level. RE laboratories also retained spares for potential immunohistochemistry less often and for shorter periods. Use of p63 as the sole basal cell marker was more common in RE. There are marked differences in procurement, handling and processing of PNBx in laboratories across Europe. This data can help the development of best practice guidelines.
Determination of emamectin benzoate in medicated fish feed: a multisite study.
Farer, Leslie J
2005-01-01
A new method was developed for the quantitation of emamectin benzoate in medicated fish feed at levels between 1 and 30 ppm. The new procedure, based on a previously reported assay, consists of a wet methanolic extraction of ground feed, followed by solid-phase extraction and injection onto a gradient liquid chromatographic system. A multisite study involving 3 laboratories (the developing laboratory and 2 independent laboratories) was performed to evaluate precision, recovery, linearity, and sensitivity. Mean recove;ries for triplicate analyses at 3 levels, performed by 2 analysts per laboratory, were between 89 and 97%, with coefficients of variation ranging from 1.6 to 8.6%. Coefficients of determination (r2) obtained from the plotted data were > or =0.993. The precision of the method, determined from 6 replicate preparations from the same batch of medicated feed assayed in 3 separate trials per laboratory, was between 0.6 and 5.8%. The quantitation limit was established at 0.5 ppm. Specificity and robustness studies were performed by the developing laboratory.
Self-reported and laboratory evaluation of late pregnancy nicotine exposure and drugs of abuse.
Hall, E S; Wexelblatt, S L; Greenberg, J M
2016-10-01
The objective of this study was to evaluate the prevalence of late pregnancy nicotine exposures, including secondhand smoke exposures, and to evaluate the associated risk of exposure to drugs of abuse. The study was a retrospective single-center cohort analysis of more than 18 months. We compared self-reported smoking status from vital birth records with mass spectrometry laboratory results of maternal urine using a chi-square test. Logistic regression estimated adjusted odds for detection of drugs of abuse based on nicotine detection. Compared with 8.6% self-reporting cigarette use, mass spectrometry detected high-level nicotine exposures for 16.5% of 708 women (P<0.001) and an additional 7.5% with low-level exposures. We identified an increased likelihood of exposure to drugs of abuse, presented as adjusted odds ratios, (95% confidence interval (CI), for both low-level (5.69, CI: 2.09 to 15.46) and high-level (13.93, CI: 7.06 to 27.49) nicotine exposures. Improved measurement tactics are critically needed to capture late pregnancy primary and passive nicotine exposures from all potential sources.
DOE Office of Scientific and Technical Information (OSTI.GOV)
R. C. Bartholomay; B. V. Twining; L. J. Campbell
1999-06-01
The U.S. Geological Survey and the Idaho Department of Water Resources, in cooperation with the U.S. Department of Energy, sampled 18 sites as part of the fourth round of a long-term project to monitor water quality of the Snake River Plain aquifer from the southern boundary of the Idaho National Engineering and Environmental Laboratory to the Hagerman area. The samples were analyzed for selected radiochemical and chemical constituents. The samples were collected from 2 domestic wells, 12 irrigation wells, 2 stock wells, 1 spring, and 1 public supply well. Two quality-assurance samples also were collected and analyzed. None of themore » reported radiochemical or chemical constituent concentrations exceeded the established maximum contaminant levels for drinking water. Many of the radionuclide- and inorganic-constituent concentrations were greater than the respective reporting levels. Most of the organic-constituent concentrations were less than the reporting levels.« less
Chanat, Jeffrey G.; Moyer, Douglas L.; Blomquist, Joel D.; Hyer, Kenneth E.; Langland, Michael J.
2016-01-13
Inconsistencies related to changing laboratory methods were also examined via two manipulative experiments. In the first experiment, increasing and decreasing “stair-step” patterns of changes in censoring level, overall representing a factor-of-five change in the laboratory reporting limit, were artificially imposed on a 27-year record with no censoring and a period-of-record concentration trend of –68.4 percent. Trends estimated on the basis of the manipulated records were broadly similar to the original trend (–63.6 percent for decreasing censoring levels and –70.3 percent for increasing censoring levels), lending a degree of confidence that the survival regression routines upon which WRTDS is based are generally robust to data censoring. The second experiment considered an abrupt disappearance of low-concentration observations of total phosphorus, associated with a laboratory method change and not reflected through censoring, near the middle of a 28-year record. By process of elimination, an upward shift in the estimated flow-normalize concentration trend line around the same time was identified as a likely artifact resulting from the laboratory method change, although a contemporaneous change in watershed processes cannot be ruled out. Decisions as to how to treat records with potential sampling protocol or laboratory methods-related artifacts should be made on a case-by-case basis, and trend results should be appropriately qualified.
Bronić, Ana; Herak, Desiree Coen; Margetić, Sandra; Milić, Marija
2017-02-15
The objective of this survey was to assess current policies and practice in haemostasis testing among both hospital and outpatient laboratories in Republic of Croatia. A questionnaire with seventy questions divided into nine sections was created in May 2015. Participants were asked about their practice related to test request form, sample collection, prothrombin time (PT) and activated partial thromboplastin time assays, other individual haemostasis assays, point-of-care testing (POCT), reporting of coagulation tests results and quality assurance of procedures, the personnel and other laboratory resources, as well as on issues related to education and implementation of additional coagulation assays in their laboratory. The survey was administered and data were collected between June and September 2015. A total survey response rate was 104/170 (61.2%). Most respondents were faced with incomplete information on prescribed therapy and diagnosis on the test request or inappropriate samples withdrawn on distant locations, but also do not have protocols for handling samples with high haematocrit values. Reporting of PT-INR and D-dimer results was different between laboratories. Although almost all laboratories developed a critical value reporting system, reporting a value to general practitioners is still a problem. Result on coagulation POCT testing showed that not all devices were supervised by laboratories, which is not in compliance with Croatian Chamber of Medical Biochemistry acts. Obtained results highlighted areas that need improvement and different practice patterns in particular field of haemostasis testing among laboratories. A harmonization of the overall process of haemostasis testing at national level should be considered and undertaken.
Bronić, Ana; Herak, Desiree Coen; Margetić, Sandra; Milić, Marija
2017-01-01
Introduction The objective of this survey was to assess current policies and practice in haemostasis testing among both hospital and outpatient laboratories in Republic of Croatia. Materials and methods A questionnaire with seventy questions divided into nine sections was created in May 2015. Participants were asked about their practice related to test request form, sample collection, prothrombin time (PT) and activated partial thromboplastin time assays, other individual haemostasis assays, point-of-care testing (POCT), reporting of coagulation tests results and quality assurance of procedures, the personnel and other laboratory resources, as well as on issues related to education and implementation of additional coagulation assays in their laboratory. The survey was administered and data were collected between June and September 2015. Results A total survey response rate was 104/170 (61.2%). Most respondents were faced with incomplete information on prescribed therapy and diagnosis on the test request or inappropriate samples withdrawn on distant locations, but also do not have protocols for handling samples with high haematocrit values. Reporting of PT-INR and D-dimer results was different between laboratories. Although almost all laboratories developed a critical value reporting system, reporting a value to general practitioners is still a problem. Result on coagulation POCT testing showed that not all devices were supervised by laboratories, which is not in compliance with Croatian Chamber of Medical Biochemistry acts. Conclusion Obtained results highlighted areas that need improvement and different practice patterns in particular field of haemostasis testing among laboratories. A harmonization of the overall process of haemostasis testing at national level should be considered and undertaken. PMID:28392741
Tethered variable gravity laboratory study: Low gravity process identification report
NASA Technical Reports Server (NTRS)
Briccarello, M.
1989-01-01
Experiments are described performable in the variable gravity environment, and the related compatible/beneficial residual accelerations, both for pure and applied research in the fields of Fluid Mechanics (static and dynamic), Materials Sciences (Crystal Growth, Metal and Alloy Solidification, Glasses, etc.), and Life Sciences, so as to assess the relevance of a variable G-level laboratory.
Effect of Cooperative Problem-Based Lab Instruction on Metacognition and Problem-Solving Skills
ERIC Educational Resources Information Center
Sandi-Urena, Santiago; Cooper, Melanie; Stevens, Ron
2012-01-01
While most scientists agree that laboratory work is an important part of introductory science courses, there is scant evidence for the relationship between laboratory work and student learning, particularly at the college level. This work reports the quantitative component of a mixed-methods study of the effect of cooperative problem-based…
ERIC Educational Resources Information Center
MacDonald, Gina
2008-01-01
This report describes a biochemistry laboratory that is completely project-oriented. Upper-level biology and chemistry majors work in teams to purify a protein of their choice. After the student groups have completed literature searches, ordered reagents, and made buffers they continue to learn basic protein purification and biochemical techniques…
Radon intercomparisons at EML, January 1983 and February 1984
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fisenne, I.M.; George, A.C.; Keller, H.W.
1985-02-01
This report summarizes the results of two radon measurement intercomparison exercises held at the Environmental Measurements Laboratory (EML) in January 1983 and February 1984. Nineteen organizations, including five US federal facilities, one national laboratory, two state laboratories, six universities, three private sector laboratories and two non-US facilities participated in these exercises. The results indicate good agreement among the participants at /sup 222/Rn concentration levels of 50 and 80 pCi.L/sup -1/. Improvements in the EML calibration facilities, and the participation of two US laboratories in a Nuclear Energy Agency intercomparison program are also discussed. 8 references, 6 figures, 8 tables.
Bartlett, John M S; Campbell, Fiona M; Ibrahim, Merdol; Thomas, Jeremy; Wencyk, Pete; Ellis, Ian; Kay, Elaine; Connolly, Yvonne; O'Grady, Anthony; Barnett, Sarah; Starczynski, Jane; Cunningham, Paul; Miller, Keith
2010-02-01
To assess a new HER2 fluorescence in situ hybridization (FISH) test and report on multicentre intrasite and intersite variation. HER2 results were scored from 45 breast cancers in eight laboratories using the Kreatech Poseidon HER2 FISH probe (Kreatech Diagnostics, Amsterdam, the Netherlands). Overall, 80.9% of cores were successfully analysed. Mean intrasite variation for HER2 ratio assessment was low (4.74%). Intersite variation in ratio was in line with previous reports (11.9+/-0.8%) for both reference and non-reference laboratories; only one laboratory displayed significantly higher intersite variation (P=0.009) than the remaining seven laboratories. The overall incidence of misclassification of cores was <1.3%, demonstrating an excellent level of concordance (>98.7%) across all eight laboratories, irrespective of whether they were 'reference' or 'routine diagnostic' laboratories. The Kreatech Poseidon HER2 FISH test is robust and reproducible. Highly quantitatively reproducible FISH results were obtained from eight 'diagnostic' and 'reference' laboratories; however, continued quality assessments are essential to good performance.
Deans, Zandra C; Tull, Justyna; Beighton, Gemma; Abbs, Stephen; Robinson, David O; Butler, Rachel
2011-11-01
Laboratories are increasingly required to perform molecular tests for the detection of mutations in the KRAS gene in metastatic colorectal cancers to allow better clinical management and more effective treatment for these patients. KRAS mutation status predicts a patient's likely response to the monoclonal antibody cetuximab. To provide a high standard of service, these laboratories require external quality assessment (EQA) to monitor the level of laboratory output and measure the performance of the laboratory against other service providers. National External Quality Assurance Services for Molecular Genetics provided a pilot EQA scheme for KRAS molecular analysis in metastatic colorectal cancers during 2009. Very few genotyping errors were reported by participating laboratories; however, the reporting nomenclature of the genotyping results varied considerably between laboratories. The pilot EQA scheme highlighted the need for continuing EQA in this field which will assess the laboratories' ability not only to obtain accurate, reliable results but also to interpret them safely and correctly ensuring that the referring clinician has the correct information to make the best clinical therapeutic decision for their patient.
NASA Technical Reports Server (NTRS)
Borsky, P. N.
1977-01-01
Residents living in close, middle and distant areas from JFK Airport were included in a field interview and laboratory study. Judgments were made of simulated aircraft noise exposures of comparable community indoor noise levels and mixes of aircraft. Each group of subjects judged the levels of noise typical for its distance area. Four different numbers of flyovers were tested: less than average for each area, the approximate average, the peak number, or worst day, and above peak number. The major findings are: (1) the reported integrated field annoyance is best related to the annoyance reported for the simulated approximate worst day exposure in the laboratory; (2) annoyance is generally less when there are fewer aircraft flyovers, and the subject has less fear of crashes and more favorable attitudes toward airplanes; (3) beliefs in harmful health effects and misfeasance by operators of aircraft are also highly correlated with fear and noise annoyance; (4) in direct retrospective comparisons of number of flights, noise levels and annoyance, subjects more often said the worst day laboratory exposured more like their usual home environments; and (5) subjects do not expect an annoyance-free environment. Half of the subjects can accept an annoyance level of 5 to 6 from a possible annoyance range of 0 to 9, 28% can live with an annoyance intensity of 7, and only 5% can accept the top scores of 8 to 9.
Surveillance of laboratory exposures to human pathogens and toxins: Canada 2016.
Bienek, A; Heisz, M; Su, M
2017-11-02
Canada recently enacted legislation to authorize the collection of data on laboratory incidents involving a biological agent. This is done by the Public Health Agency of Canada (PHAC) as part of a comprehensive national program that protects Canadians from the health and safety risks posed by human and terrestrial animal pathogens and toxins. To describe the first year of data on laboratory exposure incidents and/or laboratory-acquired infections in Canada since the Human Pathogens and Toxins Regulations came into effect. Incidents that occurred between January 1 and December 31, 2016 were self-reported by federally-regulated parties across Canada using a standardized form from the Laboratory Incident Notification Canada (LINC) surveillance system. Exposure incidents were described by sector, frequency of occurrence, timeliness of reporting, number of affected persons, human pathogens and toxins involved, causes and corrective actions taken. Microsoft Excel 2010 was used for basic descriptive analyses. In 2016, 46 exposure incidents were reported by holders of 835 active licences in Canada representing 1,352 physical areas approved for work involving a biological agent, for an overall incidence of 3.4%. The number of incidents was highest in the academic (n=16; 34.8%) and hospital (n=12; 26.1%) sectors, while the number of reported incidents was relatively low in the private industry sector. An average of four to five incidents occurred each month; the month of September presented as an outlier with 10 incidents. : A total of 100 people were exposed, with no reports of secondary exposure. Four incidents led to suspected (n=3) or confirmed (n=1) cases of laboratory-acquired infection. Most incidents involved pathogens classified at a risk group 2 level that were manipulated in a containment level 2 laboratory (91.3%). Over 22 different species of human pathogens and toxins were implicated, with bacteria the most frequent (34.8%), followed by viruses (26.1%). Eleven (23.9%) incidents involved a security sensitive biologic agent. Procedure breaches (n=15) and sharps-related incidents (n=14) were the most common antecedents to an exposure. In 10 (21.7%) cases, inadvertent possession (i.e., isolation of an unexpected biological agent during routine work) played a role. Possible improvements to standard operating procedures were cited in 71.7% of incidents. Improvements were also indicated for communication (26.1%) and management (23.9%). The Laboratory Incident Notification Canada is one of the first surveillance systems in the world to gather comprehensive data on laboratory incidents involving human pathogens and toxins. Exposure incidents reported in the first year were relatively rare, occurring in less than 4% of containment zones within laboratory settings.
Surveillance of laboratory exposures to human pathogens and toxins: Canada 2016
Bienek, A; Heisz, M; Su, M
2017-01-01
Background Canada recently enacted legislation to authorize the collection of data on laboratory incidents involving a biological agent. This is done by the Public Health Agency of Canada (PHAC) as part of a comprehensive national program that protects Canadians from the health and safety risks posed by human and terrestrial animal pathogens and toxins. Objective To describe the first year of data on laboratory exposure incidents and/or laboratory-acquired infections in Canada since the Human Pathogens and Toxins Regulations came into effect. Methods Incidents that occurred between January 1 and December 31, 2016 were self-reported by federally-regulated parties across Canada using a standardized form from the Laboratory Incident Notification Canada (LINC) surveillance system. Exposure incidents were described by sector, frequency of occurrence, timeliness of reporting, number of affected persons, human pathogens and toxins involved, causes and corrective actions taken. Microsoft Excel 2010 was used for basic descriptive analyses. Results In 2016, 46 exposure incidents were reported by holders of 835 active licences in Canada representing 1,352 physical areas approved for work involving a biological agent, for an overall incidence of 3.4%. The number of incidents was highest in the academic (n=16; 34.8%) and hospital (n=12; 26.1%) sectors, while the number of reported incidents was relatively low in the private industry sector. An average of four to five incidents occurred each month; the month of September presented as an outlier with 10 incidents. A total of 100 people were exposed, with no reports of secondary exposure. Four incidents led to suspected (n=3) or confirmed (n=1) cases of laboratory-acquired infection. Most incidents involved pathogens classified at a risk group 2 level that were manipulated in a containment level 2 laboratory (91.3%). Over 22 different species of human pathogens and toxins were implicated, with bacteria the most frequent (34.8%), followed by viruses (26.1%). Eleven (23.9%) incidents involved a security sensitive biologic agent. Procedure breaches (n=15) and sharps-related incidents (n=14) were the most common antecedents to an exposure. In 10 (21.7%) cases, inadvertent possession (i.e., isolation of an unexpected biological agent during routine work) played a role. Possible improvements to standard operating procedures were cited in 71.7% of incidents. Improvements were also indicated for communication (26.1%) and management (23.9%). Conclusions The Laboratory Incident Notification Canada is one of the first surveillance systems in the world to gather comprehensive data on laboratory incidents involving human pathogens and toxins. Exposure incidents reported in the first year were relatively rare, occurring in less than 4% of containment zones within laboratory settings. PMID:29770052
Einstein, Andrew J.; Berman, Daniel S.; Min, James K.; Hendel, Robert C.; Gerber, Thomas C.; Carr, J. Jeffrey; Cerqueira, Manuel D.; Cullom, S. James; DeKemp, Robert; Dickert, Neal; Dorbala, Sharmila; Garcia, Ernest V.; Gibbons, Raymond J.; Halliburton, Sandra S.; Hausleiter, Jörg; Heller, Gary V.; Jerome, Scott; Lesser, John R.; Fazel, Reza; Raff, Gilbert L.; Tilkemeier, Peter; Williams, Kim A.; Shaw, Leslee J.
2014-01-01
Objective To identify key components of a radiation accountability framework fostering patient-centered imaging and shared decision-making in cardiac imaging. Background An NIH-NHLBI/NCI-sponsored symposium was held in November 2012 to address these issues. Methods Symposium participants, working in three tracks, identified key components of a framework to target critical radiation safety issues for the patient, the laboratory, and the larger population of patients with known or suspected cardiovascular disease. Results Use of ionizing radiation during an imaging procedure should be disclosed to all patients by the ordering provider at the time of ordering, and reinforced by the performing provider team. An imaging protocol with effective dose ≤3mSv is considered very low risk, not warranting extensive discussion or written consent. However, a protocol effective dose <20mSv was proposed as a level requiring particular attention in terms of shared decision-making and either formal discussion or written informed consent. Laboratory reporting of radiation dosimetry is a critical component of creating a quality laboratory fostering a patient-centered environment with transparent procedural methodology. Efforts should be directed to avoiding testing involving radiation, in patients with inappropriate indications. Standardized reporting and diagnostic reference levels for computed tomography and nuclear cardiology are important for the goal of public reporting of laboratory radiation dose levels in conjunction with diagnostic performance. Conclusions The development of cardiac imaging technologies revolutionized cardiology practice by allowing routine, noninvasive assessment of myocardial perfusion and anatomy. It is now incumbent upon the imaging community to create an accountability framework to safely drive appropriate imaging utilization. PMID:24530677
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The Department of Energy Order DOE 5000.4A establishes DOE`s policy and guidelines regarding Laboratory Directed Research and Development (LDRD) at its multiprogram laboratories. As described in 5000.4A, LDRD is ``research and development of a creative and innovative nature which is selected by the Laboratory Director or his or her designee, for the purpose of maintaining the scientific and technological vitality of the Laboratory and to respond to scientific and technological opportunities in conformance with the guidelines in this Order. LDRD includes activities previously defined as ER&D, as well as other discretionary research and development activities not provided for in amore » DOE program.`` Consistent with the Mission Statement and Strategic Plan provided in PNL`s Institutional Plan, the LDRD investments are focused on developing new and innovative approaches in research related to our ``core competencies.`` Currently, PNL`s core competencies have been identified as integrated environmental research; process technology; energy systems research. In this report, the individual summaries of Laboratory-level LDRD projects are organized according to these core competencies. The largest proportion of Laboratory-level LDRD funds is allocated to the core competency of integrated environmental research. A significant proportion of PNL`s LDRD funds are also allocated to projects within the various research centers that are proposed by individual researchers or small research teams. The projects are described in Section 2.0. The projects described in this report represent PNL`s investment in its future and are vital to maintaining the ability to develop creative solutions for the scientific and technical challenges faced by DOE and the nation. In accordance with DOE guidelines, the report provides an overview of PNL`s LDRD program and the management process used for the program and project summaries for each LDRD project.« less
Scobie, Andrea
2011-04-01
To identify risk factors associated with self-reported medical, medication and laboratory error in eight countries. The Commonwealth Fund's 2008 International Health Policy Survey of chronically ill patients in eight countries. None. A multi-country telephone survey was conducted between 3 March and 30 May 2008 with patients in Australia, Canada, France, Germany, the Netherlands, New Zealand, the UK and the USA who self-reported being chronically ill. A bivariate analysis was performed to determine significant explanatory variables of medical, medication and laboratory error (P < 0.01) for inclusion in a binary logistic regression model. The final regression model included eight risk factors for self-reported error: age 65 and under, education level of some college or less, presence of two or more chronic conditions, high prescription drug use (four+ drugs), four or more doctors seen within 2 years, a care coordination problem, poor doctor-patient communication and use of an emergency department. Risk factors with the greatest ability to predict experiencing an error encompassed issues with coordination of care and provider knowledge of a patient's medical history. The identification of these risk factors could help policymakers and organizations to proactively reduce the likelihood of error through greater examination of system- and organization-level practices.
De Schutter, H; Van Damme, N; Colpaert, C; Galant, C; Lambein, K; Cornelis, A; Neven, P; Van Eycken, E
2015-04-01
Given the crucial role of pathology reporting in the management of breast cancers, we aimed to investigate the quality and variability of breast cancer pathology reporting in Belgium. Detailed information on non-molecular and molecular parameters was retrieved from the pathology protocols available at the Belgian Cancer Registry for 10,007 breast cancers diagnosed in Belgium in 2008. Substantial underreporting was shown for several clinically relevant non-molecular parameters, such as lymphovascular invasion. High-volume laboratories performed only slightly better than others, and analyses at the individual laboratory level showed clear inter-laboratory variability in reporting for all volume categories. Information on ER/PR and HER2 IHC was mentioned in respectively 91.7% and 90.8% of evaluative cases. HER2 ISH data were available for 78.5% of the cases judged to be 2+ for HER2 IHC. For cases with different specimens analysed, discordance between these specimens was highest for HER2, followed by PR. For HER2, results obtained from different laboratories were even less concordant. In addition, inter-laboratory differences were noted in the used ER/PR scoring systems, the proportion of ER-/PR+ cases, and the relation between histological grade and ER/PR positivity. Data on Ki67 were only available for 43.8% of the investigated cases, and showed inconsistent use of cut-off values. Breast pathology reporting in Belgium in 2008 was suboptimal and showed considerable inter-laboratory variability. Synoptic reporting has been proposed as a facilitator towards increased reporting quality and harmonization, but the lack of aligned informatics remains a major hurdle in its concrete implementation. Copyright © 2014 Elsevier Ltd. All rights reserved.
U.S. Ebola Treatment Center Clinical Laboratory Support
Jelden, Katelyn C.; Iwen, Peter C.; Herstein, Jocelyn J.; Biddinger, Paul D.; Kraft, Colleen S.; Saiman, Lisa; Smith, Philip W.; Hewlett, Angela L.; Gibbs, Shawn G.
2016-01-01
Fifty-five hospitals in the United States have been designated Ebola treatment centers (ETCs) by their state and local health authorities. Designated ETCs must have appropriate plans to manage a patient with confirmed Ebola virus disease (EVD) for the full duration of illness and must have these plans assessed through a CDC site visit conducted by an interdisciplinary team of subject matter experts. This study determined the clinical laboratory capabilities of these ETCs. ETCs were electronically surveyed on clinical laboratory characteristics. Survey responses were returned from 47 ETCs (85%). Forty-one (87%) of the ETCs planned to provide some laboratory support (e.g., point-of-care [POC] testing) within the room of the isolated patient. Forty-four (94%) ETCs indicated that their hospital would also provide clinical laboratory support for patient care. Twenty-two (50%) of these ETC clinical laboratories had biosafety level 3 (BSL-3) containment. Of all respondents, 34 (72%) were supported by their jurisdictional public health laboratory (PHL), all of which had available BSL-3 laboratories. Overall, 40 of 44 (91%) ETCs reported BSL-3 laboratory support via their clinical laboratory and/or PHL. This survey provided a snapshot of the laboratory support for designated U.S. ETCs. ETCs have approached high-level isolation critical care with laboratory support in close proximity to the patient room and by distributing laboratory support among laboratory resources. Experts might review safety considerations for these laboratory testing/diagnostic activities that are novel in the context of biocontainment care. PMID:26842705
FY 2017 – Thermal Aging Effects on Advanced Structural Materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Meimei; Natesan, K; Chen, Wei-Ying
This report provides an update on the evaluation of the effect of thermal aging on tensile properties of existing laboratory-sized heats of Alloy 709 austenitic stainless steel and the completion of effort on the thermal aging effect on the tensile properties of optimized G92 ferritic-martensitic steel. The report is a Level 3 deliverable in FY17 (M3AT-17AN1602081), under the Work Package AT-17AN160208, “Advanced Alloy Testing - ANL” performed by the Argonne National Laboratory (ANL), as part of the Advanced Reactor Technologies Program.
ERIC Educational Resources Information Center
Roberts, Jason E.; Zeng, Guang; Maron, Marta K.; Mach, Mindy; Dwebi, Iman; Liu, Yong
2016-01-01
This paper reports an undergraduate laboratory experiment to measure heterogeneous liquid/gas reaction kinetics (ozone-oleic acid and ozone-phenothrin) using a flow reactor coupled to an attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectrometer. The experiment is specially designed for an upper-level undergraduate Physical…
Princeton Plasma Physics Laboratory Annual Site Environmental Report for Calendar Year 1996
DOE Office of Scientific and Technical Information (OSTI.GOV)
J.D. Levine; V.L. Finley
1998-03-01
The results of the 1996 environmental surveillance and monitoring program for the Princeton Plasma Physics Laboratory (PPPL) are presented and discussed. The purpose of this report is to provide the US Department of Energy and the public with information on the level of radioactive and nonradioactive pollutants, if any, that are added to the environment as a result of PPPL's operations. During Calendar Year 1996, PPPL's Tokamak Fusion Test Reactor (TFTR) continued to conduct fusion experiments. Having set a world record on November 2, 1994, by achieving approximately 10.7 million watts of controlled fusion power during the deuterium-tritium (D-T) plasmamore » experiments, researchers turned their attention to studying plasma science experiments, which included ''enhanced reverse shear techniques.'' Since November 1993, more than 700 tritium-fueled experiments were conducted, which generated more than 4 x 10(superscript 20) neutrons and 1.4 gigajoules of fusion energy. In 1996, the overall performance of Princeton Plasma Physics Laboratory was rated ''excellent'' by the US Department of Energy in the Laboratory Appraisal report issued in early 1997. The report cited the Laboratory's consistently excellent scientific and technological achievements and its successful management practices, which included high marks for environmental management, employee health and safety, human resources administration, science education, and communications. Groundwater investigations continued under a voluntary agreement with the New Jersey Department of Environmental Protection. PPPL monitored for the presence of nonradiological contaminants, mainly volatile organic compounds (components of degreasing solvents) and petroleum hydrocarbons (past leaks of releases of diesel fuel from underground storage tanks). Also, PPPL's radiological monitoring program characterized the ambient, background levels of tritium in the environment and from the TFTR stack; the data are presented in this report. During 1996, PPPL completed the removal of contaminated soil from two locations that were identified through the monitoring program: petroleum hydrocarbons along a drainage swale and chromium adjacent to the cooling tower.« less
NASA Astrophysics Data System (ADS)
Yttri, K. E.; Schnelle-Kreiss, J.; Maenhaut, W.; Alves, C.; Bossi, R.; Bjerke, A.; Claeys, M.; Dye, C.; Evtyugina, M.; García-Gacio, D.; Gülcin, A.; Hillamo, R.; Hoffer, A.; Hyder, M.; Iinuma, Y.; Jaffrezo, J.-L.; Kasper-Giebl, A.; Kiss, G.; López-Mahia, P. L.; Pio, C.; Piot, C.; Ramirez-Santa-Cruz, C.; Sciare, J.; Teinilä, K.; Vermeylen, R.; Vicente, A.; Zimmermann, R.
2014-07-01
The monosaccharide anhydrides (MAs) levoglucosan, galactosan and mannosan are products of incomplete combustion and pyrolysis of cellulose and hemicelluloses, and are found to be major constituents of biomass burning aerosol particles. Hence, ambient aerosol particle concentrations of levoglucosan are commonly used to study the influence of residential wood burning, agricultural waste burning and wild fire emissions on ambient air quality. A European-wide intercomparison on the analysis of the three monosaccharide anhydrides was conducted based on ambient aerosol quartz fiber filter samples collected at a Norwegian urban background site during winter. Thus, the samples' content of MAs is representative for biomass burning particles originating from residential wood burning. The purpose of the intercomparison was to examine the comparability of the great diversity of analytical methods used for analysis of levoglucosan, mannosan and galactosan in ambient aerosol filter samples. Thirteen laboratories participated, of which three applied High-Performance Anion-Exchange Chromatography (HPAEC), four used High-Performance Liquid Chromatography (HPLC) or Ultra-Performance Liquid Chromatography (UPLC), and six resorted to Gas Chromatography (GC). The analytical methods used were of such diversity that they should be considered as thirteen different analytical methods. All of the thirteen laboratories reported levels of levoglucosan, whereas nine reported data for mannosan and/or galactosan. Eight of the thirteen laboratories reported levels for all three isomers. The accuracy for levoglucosan, presented as the mean percentage error (PE) for each participating laboratory, varied from -63 to 23%; however, for 62% of the laboratories the mean PE was within ±10%, and for 85% the mean PE was within ±20%. For mannosan, the corresponding range was -60 to 69%, but as for levoglucosan, the range was substantially smaller for a subselection of the laboratories; i.e., for 33% of the laboratories the mean PE was within ±10%. For galactosan, the mean PE for the participating laboratories ranged from -84 to 593%, and as for mannosan 33% of the laboratories reported a mean PE within ±10%. The variability of the various analytical methods, as defined by their minimum and maximum PE value, was typically better for levoglucosan than for mannosan and galactosan, ranging from 3.2 to 41% for levoglucosan, from 10 to 67% for mannosan, and from 6 to 364% for galactosan. For the levoglucosan to mannosan ratio, which may be used to assess the relative importance of softwood vs. hardwood burning, the variability only ranged from 3.5 to 24%. To our knowledge, this is the first major intercomparison on analytical methods used to quantify monosaccharide anhydrides in ambient aerosol filter samples conducted and reported in the scientific literature. The results show that for levoglucosan the accuracy is only slightly lower than that reported for analysis of SO42- on filter samples, a constituent that has been analyzed by numerous laboratories for several decades, typically by ion chromatography, and which is considered a fairly easy constituent to measure. Hence, the results obtained for levoglucosan with respect to accuracy are encouraging and suggest that levels of levoglucosan, and to a lesser extent mannosan and galactosan, obtained by most of the analytical methods currently used to quantify monosaccharide anhydrides in ambient aerosol filter samples, are comparable. Finally, the various analytical methods used in the current study should be tested for other aerosol matrices and concentrations as well, the most obvious being summertime aerosol samples affected by wild fires and/or agricultural fires.
NASA Astrophysics Data System (ADS)
Yttri, K. E.; Schnelle-Kreis, J.; Maenhaut, W.; Abbaszade, G.; Alves, C.; Bjerke, A.; Bonnier, N.; Bossi, R.; Claeys, M.; Dye, C.; Evtyugina, M.; García-Gacio, D.; Hillamo, R.; Hoffer, A.; Hyder, M.; Iinuma, Y.; Jaffrezo, J.-L.; Kasper-Giebl, A.; Kiss, G.; López-Mahia, P. L.; Pio, C.; Piot, C.; Ramirez-Santa-Cruz, C.; Sciare, J.; Teinilä, K.; Vermeylen, R.; Vicente, A.; Zimmermann, R.
2015-01-01
The monosaccharide anhydrides (MAs) levoglucosan, galactosan and mannosan are products of incomplete combustion and pyrolysis of cellulose and hemicelluloses, and are found to be major constituents of biomass burning (BB) aerosol particles. Hence, ambient aerosol particle concentrations of levoglucosan are commonly used to study the influence of residential wood burning, agricultural waste burning and wildfire emissions on ambient air quality. A European-wide intercomparison on the analysis of the three monosaccharide anhydrides was conducted based on ambient aerosol quartz fiber filter samples collected at a Norwegian urban background site during winter. Thus, the samples' content of MAs is representative for BB particles originating from residential wood burning. The purpose of the intercomparison was to examine the comparability of the great diversity of analytical methods used for analysis of levoglucosan, mannosan and galactosan in ambient aerosol filter samples. Thirteen laboratories participated, of which three applied high-performance anion-exchange chromatography (HPAEC), four used high-performance liquid chromatography (HPLC) or ultra-performance liquid chromatography (UPLC) and six resorted to gas chromatography (GC). The analytical methods used were of such diversity that they should be considered as thirteen different analytical methods. All of the thirteen laboratories reported levels of levoglucosan, whereas nine reported data for mannosan and/or galactosan. Eight of the thirteen laboratories reported levels for all three isomers. The accuracy for levoglucosan, presented as the mean percentage error (PE) for each participating laboratory, varied from -63 to 20%; however, for 62% of the laboratories the mean PE was within ±10%, and for 85% the mean PE was within ±20%. For mannosan, the corresponding range was -60 to 69%, but as for levoglucosan, the range was substantially smaller for a subselection of the laboratories; i.e. for 33% of the laboratories the mean PE was within ±10%. For galactosan, the mean PE for the participating laboratories ranged from -84 to 593%, and as for mannosan 33% of the laboratories reported a mean PE within ±10%. The variability of the various analytical methods, as defined by their minimum and maximum PE value, was typically better for levoglucosan than for mannosan and galactosan, ranging from 3.2 to 41% for levoglucosan, from 10 to 67% for mannosan and from 6 to 364% for galactosan. For the levoglucosan to mannosan ratio, which may be used to assess the relative importance of softwood versus hardwood burning, the variability only ranged from 3.5 to 24 . To our knowledge, this is the first major intercomparison on analytical methods used to quantify monosaccharide anhydrides in ambient aerosol filter samples conducted and reported in the scientific literature. The results show that for levoglucosan the accuracy is only slightly lower than that reported for analysis of SO42- (sulfate) on filter samples, a constituent that has been analysed by numerous laboratories for several decades, typically by ion chromatography and which is considered a fairly easy constituent to measure. Hence, the results obtained for levoglucosan with respect to accuracy are encouraging and suggest that levels of levoglucosan, and to a lesser extent mannosan and galactosan, obtained by most of the analytical methods currently used to quantify monosaccharide anhydrides in ambient aerosol filter samples, are comparable. Finally, the various analytical methods used in the current study should be tested for other aerosol matrices and concentrations as well, the most obvious being summertime aerosol samples affected by wildfires and/or agricultural fires.
Gastric myoelectrical and autonomic cardiac reactivity to laboratory stressors
GIANAROS, PETER J.; QUIGLEY, KAREN S.; MORDKOFF, J. TOBY; STERN, ROBERT M.
2010-01-01
We evaluated the effects of two laboratory stressors (speech preparation and isometric handgrip) on gastric myoelectrical and autonomic cardiac activity, and the extent to which autonomic responses to these stressors and somatization predict reports of motion sickness during exposure to a rotating optokinetic drum. Both stressors prompted a decrease in preejection period (PEP) and respiratory sinus arrhythmia (RSA), and an increase in a dysrhythmic pattern of gastric myoelectrical activity, termed gastric tachyarrhythmia. Stressor-induced decreases in RSA and higher somatization scores predicted increased reports of motion sickness during drum rotation. These results demonstrate that laboratory stressors concurrently affect gastric myoelectrical activity and autonomic control of the heart, and that stressor-induced decreases in RSA and higher levels of somatization predict motion sickness susceptibility. PMID:11446577
Physiological Responses to Racism and Discrimination: An Assessment of the Evidence
Harrell, Jules P.; Hall, Sadiki; Taliaferro, James
2003-01-01
A growing body of research explores the impact of encounters with racism or discrimination on physiological activity. Investigators have collected these data in laboratories and in controlled clinical settings. Several but not all of the studies suggest that higher blood pressure levels are associated with the tendency not to recall or report occurrences identified as racist and discriminatory. Investigators have reported that physiological arousal is associated with laboratory analogues of ethnic discrimination and mistreatment. Evidence from survey and laboratory studies suggests that personality variables and cultural orientation moderate the impact of racial discrimination. The neural pathways that mediate these physiological reactions are not known. The evidence supports the notion that direct encounters with discriminatory events contribute to negative health outcomes. PMID:12554577
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bartholomay, R.C.; Edwards, D.D.; Campbell, L.J.
1993-11-01
The US Geological Survey and the Idaho Department of Water Resources, in response to a request from the US Department of Energy, sampled 18 sites as part of a long-term project to monitor water quality of the Snake River Plain aquifer from the southern boundary of the Idaho National Engineering Laboratory to the Hagerman area. Water samples were collected and analyzed for manmade pollutants and naturally occurring constituents. The samples were collected from six irrigation wells, seven domestic wells, two springs, one stock well, one dairy well, and one observation well. Quality assurance samples also were collected and analyzed. Themore » water samples were analyzed for selected radionuclides, inorganic constituents, organic compounds, and bacteria. None of the samples analyzed for radionuclides, inorganic constituents, or organic compounds exceeded the established maximum contaminant levels for drinking water. Most of the radionuclide and inorganic constituent concentrations exceeded their respective reporting levels. All the samples analyzed for dissolved organic carbon had concentrations that exceeded their reporting level. Concentrations of 1,1,1 -trichloroethane exceeded the reporting level in two water samples. Two samples and a quality assurance replicate contained reportable concentrations of 2, 4-D. One sample contained fecal coliform bacteria counts that exceeded established maximum contaminant levels for drinking water.« less
Arneson, Wendy; Robinson, Cathy; Nyary, Bryan
2013-01-01
There is a worldwide shortage of qualified laboratory personnel to provide adequate testing for the detection and monitoring of diseases. In an effort to increase laboratory capacity in developing countries, new skills have been introduced into laboratory services. Curriculum revision with a focus on good laboratory practice is an important aspect of supplying entry-level graduates with the competencies needed to meet the current needs. Gaps in application and problem-solving competencies of newly graduated laboratory personnel were discovered in Ethiopia, Tanzania and Kenya. New medical laboratory teaching content was developed in Ethiopia, Tanzania and Kenya using national instructors, tutors, and experts and consulting medical laboratory educators from the United States of America (USA). Workshops were held in Ethiopia to create standardised biomedical laboratory science (BMLS) lessons based on recently-revised course objectives with an emphasis on application of skills. In Tanzania, course-module teaching guides with objectives were developed based on established competency outcomes and tasks. In Kenya, example interactive presentations and lesson plans were developed by the USA medical laboratory educators prior to the workshop to serve as resources and templates for the development of lessons within the country itself. The new teaching materials were implemented and faculty, students and other stakeholders reported successful outcomes. These approaches to updating curricula may be helpful as biomedical laboratory schools in other countries address gaps in the competencies of entry-level graduates.
Dissociation in the laboratory: a comparison of strategies.
Leonard, K N; Telch, M J; Harrington, P J
1999-01-01
Several methods for inducing dissociation in the laboratory were examined in a sample of 78 undergraduate students. Participants scoring high or low on the Dissociative Experiences Scale participated in three dissociation challenge conditions: (a) dot-staring task, (b) administration of pulsed photic and audio stimulation and (c) stimulus deprivation. Participants recorded their dissociative experiences both before and after each of the three challenge conditions. Across conditions, high DES participants reported significantly more dissociative sensations than low DES participants, even after controlling for pre-challenge dissociation. Moreover, regardless of DES status, pulsed photo and audio stimulation produced the greatest level of dissociative symptoms. The findings suggest that the induction of dissociative symptoms in a nonclinical sample is easily accomplished in the laboratory and that those who report more dissociative symptoms in their day-to-day life exhibit more pronounced dissociative symptoms when undergoing dissociative challenge in the laboratory. Implications for the study and treatment of dissociative symptoms are discussed.
NASA Astrophysics Data System (ADS)
Rudd, James Andrew, II
Many students encounter difficulties engaging with laboratory-based instruction, and reviews of research have indicated that the value of such instruction is not clearly evident. Traditional forms of writing associated with laboratory activities are commonly in a style used by professional scientists to communicate developed explanations. Students probably lack the interpretative skills of a professional, and writing in this style may not support students in learning how to develop scientific explanations. The Science Writing Heuristic (SWH) is an inquiry-based approach to laboratory instruction designed in part to promote student ability in developing such explanations. However, there is not a convincing body of evidence for the superiority of inquiry-based laboratory instruction in chemistry. In a series of studies, the performance of students using the SWH student template in place of the standard laboratory report format was compared to the performance of students using the standard format. The standard reports had Title, Purpose, Procedure, Data & Observations, Calculations & Graphs, and Discussion sections. The SWH reports had Beginning Questions & Ideas, Tests & Procedures, Observations, Claims, Evidence, and Reflection sections. The pilot study produced evidence that using the SWH improved the quality of laboratory reports, improved student performance on a laboratory exam, and improved student approach to laboratory work. A main study found that SWH students statistically exhibited a better understanding of physical equilibrium when written explanations and equations were analyzed on a lecture exam and performed descriptively better on a physical equilibrium practical exam task. In another main study, the activities covering the general equilibrium concept were restructured as an additional change, and it was found that SWH students exhibited a better understanding of chemical equilibrium as shown by statistically greater success in overcoming the common confusion of interpreting equilibrium as equal concentrations and by statistically better performance when explaining aspects of chemical equilibrium. Both main studies found that students and instructors spent less time on the SWH reports and that students preferred the SWH approach because it increased their level of mental engagement. The studies supported the conclusion that inquiry-based laboratory instruction benefits student learning and attitudes.
Pérez-Edgar, Koraly; Schmidt, Louis A; Henderson, Heather A; Schulkin, Jay; Fox, Nathan A
2008-08-01
Behavioral problems in young children can take on a variety of forms, which are linked to distinct antecedents and co-occurring markers. Internalizing difficulties in young children, for example, have been linked to individual differences in infant temperament and cortisol levels. In addition, there is growing evidence that these biobehavioral mechanisms are also shaped by gender. Four-year-old children participated in a study examining the relations between salivary cortisol and behavioral maladjustment as a function of gender and temperament. Both longitudinal (maternal report of infant temperament at 9 months) and concurrent (morning salivary cortisol at age 4) data were used to predict two forms of maladjustment: 'Withdrawal' (maternal report of internalizing behavior and laboratory observation of social reticence) and 'Acting Out' (maternal report of externalizing behavior and laboratory observation of solitary active play). High basal cortisol levels were strongly associated with Withdrawal in male participants. However, the relation was significant only in boys who exhibited high levels of negative temperament in infancy. There were no comparable findings with 'Acting Out' beyond a main effect of gender reflecting greater difficulty in boys. The data suggested that there are unique biobehavioral mechanisms shaping specific patterns of maladjustment in childhood.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelly, Elizabeth J.; Dewart, Jean Marie; Deola, Regina
This report provides site-specific return level analyses for rain, snow, and straight-line wind extreme events. These analyses are in support of the 10-year review plan for the assessment of meteorological natural phenomena hazards at Los Alamos National Laboratory (LANL). These analyses follow guidance from Department of Energy, DOE Standard, Natural Phenomena Hazards Analysis and Design Criteria for DOE Facilities (DOE-STD-1020-2012), Nuclear Regulatory Commission Standard Review Plan (NUREG-0800, 2007) and ANSI/ ANS-2.3-2011, Estimating Tornado, Hurricane, and Extreme Straight-Line Wind Characteristics at Nuclear Facility Sites. LANL precipitation and snow level data have been collected since 1910, although not all years are complete.more » In this report the results from the more recent data (1990–2014) are compared to those of past analyses and a 2004 National Oceanographic and Atmospheric Administration report. Given the many differences in the data sets used in these different analyses, the lack of statistically significant differences in return level estimates increases confidence in the data and in the modeling and analysis approach.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Finley, V.L. and Levine, J.D.
The results of the 1997 environmental surveillance and monitoring program for the Princeton Plasma Physics Laboratory (PPPL) are presented and discussed. The purpose of this report is to provide the U.S. Department of Energy and the public with information on the level of radioactive and non-radioactive pollutants, if any, that are added to the environment as a result of PPPL's operations. During Calendar Year 1997, PPPL's Tokamak Fusion Test Reactor (TFTR) completed fifteen years of fusion experiments begun in 1982. Over the course of three and half years of deuterium-tritium (D-T) plasma experiments, PPPL set a world record of 10.7more » million watts of controlled fusion power, more than 700 tritium shots pulsed into the reactor vessel generating more than 5.6 x 10 20 neutron and 1.6 gigajoules of fusion energy and researchers studied plasma science experimental data, which included "enhanced reverse shear techniques." As TFTR was completing its historic operations, PPPL participated with the Oak Ridge National Laboratory, Columbia University, and the University of Washington (Seattle) in a collaboration effort to design the National Spherical Torus Experiment (NSTX). This next device, NSTX, is located in the former TFTR Hot Cell on D site, and it is designed to be a smaller and more economical torus fusion reactor. Construction of this device began in late 1997, and first plasma in scheduled for early 1999. For 1997, the U.S. Department of Energy in its Laboratory Appraisal report rated the overall performance of Princeton Plasma Physics Laboratory as "excellent." The report cited the Laboratory's consistently excellent scientific and technological achievements and its successful management practices, which included high marks for environmental management, employee health and safety, human resources administration, science education, and communications. Groundwater investigations continued under a voluntary agreement with the New Jersey Department of Environmental Protection. PPPL monitored the presence of non-radiological contaminants, mainly volatile organic compounds (components of degreasing solvents). Monitoring revealed the presence of low levels of volatile organic compounds in an adjacent area to PPPL. Also, PPPL's radiological monitoring program characterized the ambient, background levels of tritium in the environment and from the TFTR stack; the data are presented in this report.« less
Cost analysis in the toxicology laboratory.
Travers, E M
1990-09-01
The process of determining laboratory sectional and departmental costs and test costs for instrument-generated and manually generated reportable results for toxicology laboratories has been outlined in this article. It is hoped that the basic principles outlined in the preceding text will clarify and elucidate one of the most important areas needed for laboratory fiscal integrity and its survival in these difficult times for health care providers. The following general principles derived from this article are helpful aids for managers of toxicology laboratories. 1. To manage a cost-effective, efficient toxicology laboratory, several factors must be considered: the laboratory's instrument configuration, test turnaround time needs, the test menu offered, the analytic methods used, the cost of labor based on time expended and the experience and educational level of the staff, and logistics that determine specimen delivery time and costs. 2. There is a wide variation in costs for toxicologic methods, which requires that an analysis of capital (equipment) purchase and operational (test performance) costs be performed to avoid waste, purchase wisely, and determine which tests consume the majority of the laboratory's resources. 3. Toxicologic analysis is composed of many complex steps. Each step must be individually cost-accounted. Screening test results must be confirmed, and the cost for both steps must be included in the cost per reportable result. 4. Total costs will vary in the same laboratory and between laboratories based on differences in salaries paid to technical staff, differences in reagent/supply costs, the number of technical staff needed to operate the analyzer or perform the method, and the inefficient use of highly paid staff to operate the analyzer or perform the method. 5. Since direct test costs vary directly with the type and number of analyzers or methods and are dependent on the operational mode designed by the manufacturer, laboratory managers should construct an actual test-cost data base for instrument or method in use to accurately compare costs using the "bottom-up" approach. 6. Laboratory expenses can be examined from three perspectives: total laboratory, laboratory section, and subsection workstation. The objective is to track all laboratory expenses through each of these levels. 7. In the final analysis, a portion of total laboratory expenses must be allocated to each unit of laboratory output--the billable procedure or, in laboratories where tests are not billed, the tests produced.(ABSTRACT TRUNCATED AT 400 WORDS)
Diers, J; Kouriba, B; Ladan Fofana, L; Fleischmann, E; Starke, M; Diallo, S; Babin, F-X; von Bonin, J; Wölfel, R
2015-01-01
The Ebola virus, which became a global health concern in 2014, is an example of an emerging pathogen. Ebola virus disease can only be diagnosed in biosafety level 3 and 4 laboratories, which provide the security required to avoid exposure of both the staff and the environment to the pathogen. These laboratories are often far from the site of outbreaks, which may occur in rural areas or border regions (when the disease is imported from a neighboring country). Rapidly deployable laboratory units can bring the diagnosis closer to the outbreak site and thus significantly shorten the time to delivery of results, thus facilitating epidemic containment. Here we report our experience from the first months of implementation in Mali of a mobile laboratory unit of the same type as the European mobile labs and we describe the workflow in the laboratory as well as the training of its Malian staff. Based on our experience and the reports of other projects, we propose a framework in which these mobile laboratory units can strengthen epidemiological surveillance and contribute to containing outbreaks of emerging diseases in sub-Saharan Africa.
du Preez, Karen; Schaaf, H Simon; Dunbar, Rory; Walters, Elisabetta; Swartz, Alvera; Solomons, Regan; Hesseling, Anneke C
2018-03-23
Tuberculosis (TB) in young and HIV-infected children is frequently diagnosed at hospital level. In settings where general hospitals do not function as TB reporting units, the burden and severity of childhood TB may not be accurately reflected in routine TB surveillance data. Given the paucibacillary nature of childhood TB, microbiological surveillance alone will miss the majority of hospital-managed children. The study objective was to combine complementary hospital-based surveillance strategies to accurately report the burden, spectrum and outcomes of childhood TB managed at referral hospital-level in a high TB burden setting. We conducted a prospective cohort study including all children (< 13 years) managed for TB at a large referral hospital in Cape Town, South Africa during 2012. Children were identified through newly implemented clinical surveillance in addition to existing laboratory surveillance. Data were collected from clinical patient records, the National Health Laboratory Service database, and provincial electronic TB registers. Descriptive statistics were used to report overall TB disease burden, spectrum, care pathways and treatment outcomes. Univariate analysis compared characteristics between children identified through the two hospital-based surveillance strategies to characterise the group of children missed by existing laboratory surveillance. During 2012, 395 children (180 [45.6%] < 2 years) were managed for TB. Clinical surveillance identified 237 (60%) children in addition to laboratory surveillance. Ninety (24.3%) children were HIV co-infected; 113 (29.5%) had weight-for-age z-scores <- 3. Extra-pulmonary TB (EPTB) was diagnosed in 188 (47.6%); 77 (19.5%) with disseminated TB. Favourable TB treatment outcomes were reported in 300/344 (87.2%) children with drug-susceptible and 50/51 (98.0%) children with drug-resistant TB. Older children (OR 1.7; 95% CI 1.0-2.8), children with EPTB (OR 2.3; 95% CI 1.5-3.6) and in-hospital deaths (OR 5.4; 95% CI 1.1-26.9) were more frequently detected by laboratory surveillance. TB/HIV co-infected children were less likely to be identified through laboratory surveillance (OR 0.3; 95% CI 0.2-0.5). The burden and spectrum of childhood TB disease managed at referral hospital level in high burden settings is substantial. Hospital-based surveillance in addition to routine TB surveillance is essential to provide a complete picture of the burden, spectrum and impact of childhood TB in settings where hospitals are not TB reporting units.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bartholomay, R.C.; Edwards, D.D.; Campbell, L.J.
1992-03-01
The US Geological Survey and the Idaho Department of Water Resources, in response to a request from the US Department of Energy, sampled 19 sites as part of a long-term project to monitor water quality of the Snake River Plain aquifer from the southern boundary of the Idaho National Engineering Laboratory to the Hagerman area. Water samples were collected and analyzed for manmade pollutants and naturally occurring constituents. The samples were collected from seven irrigation wells, five domestic wells, two springs, one stock well, two dairy wells, one observation well, and one commercial well. Two quality assurance samples also weremore » collected and analyzed. The water samples were analyzed for selected radionuclides, inorganic constituents, organic compounds, and bacteria. None of the radionuclides, inorganic constituents, or organic compounds exceeded the established maximum contaminant levels for drinking water. Most of the radionuclide and inorganic constituent concentrations exceeded their respective reporting levels. All samples analyzed for surfactants and dissolved organic carbon had concentrations that exceeded their reporting level. Toluene concentrations exceeded the reporting level in one water sample. Two samples contained fecal coliform bacteria counts that exceeded established maximum contaminant levels for drinking water.« less
Russom, Diana; Ahmed, Amira; Gonzalez, Nancy; Alvarnas, Joseph; DiGiusto, David
2012-01-01
Regulatory requirements for the manufacturing of cell products for clinical investigation require a significant level of record-keeping, starting early in process development and continuing through to the execution and requisite follow-up of patients on clinical trials. Central to record-keeping is the management of documentation related to patients, raw materials, processes, assays and facilities. To support these requirements, we evaluated several laboratory information management systems (LIMS), including their cost, flexibility, regulatory compliance, ongoing programming requirements and ability to integrate with laboratory equipment. After selecting a system, we performed a pilot study to develop a user-configurable LIMS for our laboratory in support of our pre-clinical and clinical cell-production activities. We report here on the design and utilization of this system to manage accrual with a healthy blood-donor protocol, as well as manufacturing operations for the production of a master cell bank and several patient-specific stem cell products. The system was used successfully to manage blood donor eligibility, recruiting, appointments, billing and serology, and to provide annual accrual reports. Quality management reporting features of the system were used to capture, report and investigate process and equipment deviations that occurred during the production of a master cell bank and patient products. Overall the system has served to support the compliance requirements of process development and phase I/II clinical trial activities for our laboratory and can be easily modified to meet the needs of similar laboratories.
U.S. Ebola Treatment Center Clinical Laboratory Support.
Jelden, Katelyn C; Iwen, Peter C; Herstein, Jocelyn J; Biddinger, Paul D; Kraft, Colleen S; Saiman, Lisa; Smith, Philip W; Hewlett, Angela L; Gibbs, Shawn G; Lowe, John J
2016-04-01
Fifty-five hospitals in the United States have been designated Ebola treatment centers (ETCs) by their state and local health authorities. Designated ETCs must have appropriate plans to manage a patient with confirmed Ebola virus disease (EVD) for the full duration of illness and must have these plans assessed through a CDC site visit conducted by an interdisciplinary team of subject matter experts. This study determined the clinical laboratory capabilities of these ETCs. ETCs were electronically surveyed on clinical laboratory characteristics. Survey responses were returned from 47 ETCs (85%). Forty-one (87%) of the ETCs planned to provide some laboratory support (e.g., point-of-care [POC] testing) within the room of the isolated patient. Forty-four (94%) ETCs indicated that their hospital would also provide clinical laboratory support for patient care. Twenty-two (50%) of these ETC clinical laboratories had biosafety level 3 (BSL-3) containment. Of all respondents, 34 (72%) were supported by their jurisdictional public health laboratory (PHL), all of which had available BSL-3 laboratories. Overall, 40 of 44 (91%) ETCs reported BSL-3 laboratory support via their clinical laboratory and/or PHL. This survey provided a snapshot of the laboratory support for designated U.S. ETCs. ETCs have approached high-level isolation critical care with laboratory support in close proximity to the patient room and by distributing laboratory support among laboratory resources. Experts might review safety considerations for these laboratory testing/diagnostic activities that are novel in the context of biocontainment care. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
An audit of the laboratory diagnosis of cryptosporidiosis in England and Wales.
Chalmers, Rachel M; Atchison, Christina; Barlow, Katrina; Young, Yvonne; Roche, Anita; Manuel, Rohini
2015-07-01
To assess the level of practice consistent with UK national standards for Cryptosporidium testing, an audit was performed of 156 publicly funded clinical microbiology laboratories in England and Wales between August 2013 and April 2014. Responses were received from 85 (54 %) laboratories. First line diagnostic methods used were mainly microscopy with modified Ziehl-Neelsen (mZN) or auramine phenol (AP) staining (68/85, 80 %), enzyme immunoassays (EIAs) (16/85, 19 %) or in-house PCR (1/85, 1 %). The use of EIAs was more widespread than reported previously. Various methods were used for confirmation of positive EIA reactions and laboratories frequently resorted to sending samples to the national reference laboratory for this purpose, indicating that guidance is required for performance monitoring and confirmation of positive reactions. Laboratory positivity rates were related to the diagnostic test used, with highest median rates reported by those using PCR, EIAs or AP microscopy, and the lowest by those using mZN microscopy. One-third of responding laboratories (28/85, 33 %) routinely tested all stools for Cryptosporidium. However, 16 (19 %) laboratories used stool consistency to decide whether to test for this parasite. Other selection criteria included patient age (n = 18; 21 % laboratories), history or clinical details (n = 40; 47 %), duration of hospitalization (n = 18; 21 %) or clinician requests (n = 25; 29 %). To encourage laboratories to test all stools submitted for the investigation of diarrhoeal illness for Cryptosporidium, revision of the guidance in the national standards is under way. This will enable improved assessment of the burden of illness and ability to monitor outbreaks, and measure changes in reported cases.
Comparison of four types of diet using clinical, laboratory and psychological studies
Lockie, Andrew H.; Carlson, Eleanor; Kipps, Michael; Thomson, James
1985-01-01
Thirty-seven people of different dietary habits—vegans, ovolactovegetarians, whole-food omnivores and average omnivores—were studied using nine-day weighed food intakes, clinical and laboratory assessments, standard psychology questionnaires, measurements of urinary cortisol and catecholamine levels and questionnaires on life-style and health factors. The vegan diet most clearly approximated current thinking on diet, as expressed in the NACNE Report, but was deficient in vitamin D, riboflavin, and vitamin B12. Cholesterol levels were significantly higher in both diet and serum in all groups compared with the vegans. There was no significant difference in social background, money spent on food, exercise, smoking, stress levels or psychological parameters between groups. PMID:2993600
2017-11-01
This proceedings report presents the outcomes from an international workshop supported by the European Society of Human Reproduction and Embryology (ESHRE) and Alpha Scientists in Reproductive Medicine, designed to establish consensus on definitions and recommended values for Indicators for the assisted reproductive technology (ART) laboratory. Minimum performance-level values ('competency') and aspirational ('benchmark') values were recommended for a total of 19 Indicators, including 12 Key Performance Indicators (KPIs), five Performance Indicators (PIs), and two Reference Indicators (RIs). Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Mák, Geneviève; Smith Fowler, Heather; Leaver, Chad; Hagens, Simon; Zelmer, Jennifer
2015-08-04
Web-based patient access to personal health information is limited but increasing in Canada and internationally. This exploratory study aimed to increase understanding of how Web-based access to laboratory test results in British Columbia (Canada), which has been broadly available since 2010, affects patients' experiences. In November 2013, we surveyed adults in British Columbia who had had a laboratory test in the previous 12 months. Using a retrospective cohort design, we compared reported wait-time for results, test result comprehension, and anxiety levels of "service users" who had Web-based access to their test results (n=2047) with those of a general population panel that did not have Web-based access (n=1245). The vast majority of service users (83.99%, 95% CI 82.31-85.67) said they received their results within "a few days", compared to just over a third of the comparison group (37.84%, 95% CI 34.96-40.73). Most in both groups said they understood their test results, but the rate was lower for service users than the comparison group (75.55%, 95% CI 73.58-77.49 vs 84.69%, 95% CI 82.59-86.81). There was no significant difference between groups in levels of reported anxiety after receiving test results. While most patients who received their laboratory test results online reported little anxiety after receiving their results and were satisfied with the service, there may be opportunities to improve comprehension of results.
Audiovisual physics reports: students' video production as a strategy for the didactic laboratory
NASA Astrophysics Data System (ADS)
Vinicius Pereira, Marcus; de Souza Barros, Susana; de Rezende Filho, Luiz Augusto C.; Fauth, Leduc Hermeto de A.
2012-01-01
Constant technological advancement has facilitated access to digital cameras and cell phones. Involving students in a video production project can work as a motivating aspect to make them active and reflective in their learning, intellectually engaged in a recursive process. This project was implemented in high school level physics laboratory classes resulting in 22 videos which are considered as audiovisual reports and analysed under two components: theoretical and experimental. This kind of project allows the students to spontaneously use features such as music, pictures, dramatization, animations, etc, even when the didactic laboratory may not be the place where aesthetic and cultural dimensions are generally developed. This could be due to the fact that digital media are more legitimately used as cultural tools than as teaching strategies.
Reliability in individual monitoring service.
Mod Ali, N
2011-03-01
As a laboratory certified to ISO 9001:2008 and accredited to ISO/IEC 17025, the Secondary Standard Dosimetry Laboratory (SSDL)-Nuclear Malaysia has incorporated an overall comprehensive system for technical and quality management in promoting a reliable individual monitoring service (IMS). Faster identification and resolution of issues regarding dosemeter preparation and issuing of reports, personnel enhancement, improved customer satisfaction and overall efficiency of laboratory activities are all results of the implementation of an effective quality system. Review of these measures and responses to observed trends provide continuous improvement of the system. By having these mechanisms, reliability of the IMS can be assured in the promotion of safe behaviour at all levels of the workforce utilising ionising radiation facilities. Upgradation of in the reporting program through a web-based e-SSDL marks a major improvement in Nuclear Malaysia's IMS reliability on the whole. The system is a vital step in providing a user friendly and effective occupational exposure evaluation program in the country. It provides a higher level of confidence in the results generated for occupational dose monitoring of the IMS, thus, enhances the status of the radiation protection framework of the country.
Batistatou, Anna; Cook, Martin G; Massi, Daniela
2009-05-01
In order to survey the diagnostic reporting of melanomas by European pathologists and assess their current practice and opinions on the information required in the final report, a web-based questionnaire was diffused through the members of the Dermatopathology Working Group of the European Society of Pathology. Forty replies from different pathology laboratories were collected (49%). Main prognostic parameters related to the primary tumor, including Breslow thickness, presence of ulceration, and Clark's level, as well as additional features, are reported by a large majority of laboratories. Presence of regression is reported by 90% of respondents but with different recording items. For sentinel lymph node (SLN) biopsy for melanoma, the conventional panel of antibodies includes S-100, Melan A, and HMB45. Dissection of the SLN is performed by "bivalve" or "bread loaf" approach. The number of sections cut and stained varies. Forty-four percent of respondents report depths of metastases from the capsule, while the majority report maximum dimension of the largest deposit. Results indicate that pathology reports for primary cutaneous melanoma and SLN vary between laboratories across Europe. Although the most important prognostic features are universally reported, key features which impact on prognosis and treatment are often omitted and others still require standardization.
Dougherty, Donald M.; Mathias, Charles W.; Marsh-Richard, Dawn M.; Prevette, Kristen N.; Dawes, Michael A.; Hatzis, Erin S.; Palmes, Guy; Nouvion, Sylvain O.
2011-01-01
This study examined clinical characteristics and laboratory-measured impulsive behavior of adolescents engaging in either non-suicidal self-injury with (NSSI+SA; n = 25) or without (NSSI-Only; n = 31) suicide attempts. We hypothesized that adolescent with NSSI+SI would exhibit more severe clinical symptoms and higher levels of behavioral impulsivity compared to adolescents with NSSI-Only. Adolescents were recruited from an inpatient psychiatric hospital unit and the two groups were compared on demographic characteristics, psychopathology, self-reported clinical ratings, methods of non-suicidal self-injury, and two laboratory impulsivity measures. Primary evaluations were conducted during psychiatric hospitalization, and a subset of those tested during hospitalization was retested 4-6 weeks after discharge. During hospitalization, NSSI+SA patients reported worse depression, hopelessness, and impulsivity on standard clinical measures, and demonstrated elevated impulsivity on a reward-directed laboratory measure compared to NSSI-Only patients. In the preliminary follow-up analyses, depression, hopelessness, suicidal ideation, and laboratory impulsivity were improved for both groups, but the NSSI+SA group still exhibited significantly more depressive symptoms, hopelessness, and impulsivity than the NSSI-Only group. Risk assessments for adolescents with NSSI+SA should include consideration not only of the severity of clinical symptoms but of the current level impulsivity as well. PMID:19631392
Dougherty, Donald M; Mathias, Charles W; Marsh-Richard, Dawn M; Prevette, Kristen N; Dawes, Michael A; Hatzis, Erin S; Palmes, Guy; Nouvion, Sylvain O
2009-08-30
This study examined clinical characteristics and laboratory-measured impulsive behavior of adolescents engaging in either non-suicidal self-injury with (NSSI+SA; n=25) or without (NSSI-Only; n=31) suicide attempts. We hypothesized that adolescent with NSSI+SI would exhibit more severe clinical symptoms and higher levels of behavioral impulsivity compared to adolescents with NSSI-Only. Adolescents were recruited from an inpatient psychiatric hospital unit and the two groups were compared on demographic characteristics, psychopathology, self-reported clinical ratings, methods of non-suicidal self-injury, and two laboratory impulsivity measures. Primary evaluations were conducted during psychiatric hospitalization, and a subset of those tested during hospitalization was retested 4-6 weeks after discharge. During hospitalization, NSSI+SA patients reported worse depression, hopelessness, and impulsivity on standard clinical measures, and demonstrated elevated impulsivity on a reward-directed laboratory measure compared to NSSI-Only patients. In the follow-up analyses, depression, hopelessness, suicidal ideation, and laboratory impulsivity were improved for both groups, but the NSSI+SA group still exhibited significantly more depressive symptoms, hopelessness, and impulsivity than the NSSI-Only group. Risk assessments for adolescents with NSSI+SA should include consideration not only of the severity of clinical symptoms but of the current level impulsivity as well.
Robinson, Cathy; Nyary, Bryan
2013-01-01
Background There is a worldwide shortage of qualified laboratory personnel to provide adequate testing for the detection and monitoring of diseases. In an effort to increase laboratory capacity in developing countries, new skills have been introduced into laboratory services. Curriculum revision with a focus on good laboratory practice is an important aspect of supplying entry-level graduates with the competencies needed to meet the current needs. Objectives Gaps in application and problem-solving competencies of newly graduated laboratory personnel were discovered in Ethiopia, Tanzania and Kenya. New medical laboratory teaching content was developed in Ethiopia, Tanzania and Kenya using national instructors, tutors, and experts and consulting medical laboratory educators from the United States of America (USA). Method Workshops were held in Ethiopia to create standardised biomedical laboratory science (BMLS) lessons based on recently-revised course objectives with an emphasis on application of skills. In Tanzania, course-module teaching guides with objectives were developed based on established competency outcomes and tasks. In Kenya, example interactive presentations and lesson plans were developed by the USA medical laboratory educators prior to the workshop to serve as resources and templates for the development of lessons within the country itself. Results The new teaching materials were implemented and faculty, students and other stakeholders reported successful outcomes. Conclusions These approaches to updating curricula may be helpful as biomedical laboratory schools in other countries address gaps in the competencies of entry-level graduates. PMID:29043162
Prevalence of Estimated GFR Reporting Among US Clinical Laboratories
Accetta, Nancy A.; Gladstone, Elisa H.; DiSogra, Charles; Wright, Elizabeth C.; Briggs, Michael; Narva, Andrew S.
2008-01-01
Background Routine laboratory reporting of estimated glomerular filtration rate (eGFR) may help clinicians detect kidney disease. The current national prevalence of eGFR reporting among clinical laboratories is unknown, thus the extent of the situation of laboratories not routinely reporting eGFR with serum creatinine (SCr) results is not quantified. Design Observational analysis. Setting National Kidney Disease Education Program survey of clinical laboratory conducted in 2006-7 by mail, Web, and telephone follow up. Participants A national random sample, 6,350 clinical laboratories, drawn from the Federal Clinical Laboratory Improvement Amendments database and stratified by six major laboratory types/groupings. Predictors Laboratory reports SCr results. Outcomes Reporting eGFR values along with SCr results. Measurements Percent of laboratories reporting eGFR along with reporting SCr, reporting protocol, eGFR formula used, and style of reporting cutoff values. Results Among laboratories reporting SCr, 38.4% report eGFR (physician offices, 25.8%; hospitals, 43.6%; independents, 38.9%; community clinics, 47.2%; health fair/insurance/public health, 45.5%; others, 43.2%). Physician office laboratories have a reporting prevalence lower than other laboratory types (p < 0.001). Among laboratories reporting eGFR, 66.7% do so routinely with all adult SCr determinations; 71.6% use the 4-variable Modification of Diet in Renal Disease Study equation; and 45.3% use the “>60 mL/min/1.73 m2” reporting convention. Independent laboratories are least likely to routinely report eGFR, (50.6%, p < .05) and most likely to report only when specifically requested (45.4%, p < 0.05). High-volume laboratories across all strata are more likely to report eGFR (p < 0.001). Limitations Self-reporting by laboratories, Federal database did not have names of laboratory directors/managers (intended respondents), assumed accuracy of Federal database for sample purposes. Conclusions Routine eGFR reporting with SCr is not yet universal and laboratories vary in their reporting practices. PMID:18676076
Applied use of cardiac and respiration measures: practical considerations and precautions.
Wilson, G F
1992-11-01
Cardiac and respiratory measures can be successfully applied to "real world" environments and these measures have certain advantages over both performance and subjective measures that are typically used to monitor operator state and workload. However, because of large differences between laboratory and "real world" environments one must utilize caution in directly applying laboratory data and theories to the day-to-day world environment. While most workers are highly over-trained in their jobs, laboratory subjects are often under-trained in the cognitive tasks that are used to study cognitive activity. It is possible that a substantial portion of experimental effects reported in laboratory studies is due to learning effects. In addition, relatively small changes in cardiac and respiration measures are reported to experimental manipulations in the laboratory while a much larger range of changes are reported in "real world" environments. These differences highlight questions about laboratory/real world similarities and the need to develop a database of actual work environment data. A third area of concern is the relative lack of control over the experimental situation that is the case with most applied research. The possible confounding of changes due to cognitive and physical activity levels is a major concern and strategies for overcoming these problems are suggested. The potential for valuable contributions by cardiac and respiratory measures to applied research make overcoming these difficulties worthwhile.
NASA Astrophysics Data System (ADS)
Xu, Haozhi
Students' learning in inquiry-based investigations has drawn considerable attention of the science education community. Inquiry activities can be viewed as knowledge construction processes in which students are expected to develop conceptual understanding and critical thinking abilities. Our study aimed to explore the effect of experiments with different levels of inquiry on students' interactions in the laboratory setting, as well as on students' written arguments and reflections. Our results are based on direct observations of group work in college general chemistry laboratories and analysis of associated written lab reports. The analysis of students' interactions in the laboratory was approached from three major analytic dimensions: Functional analysis, cognitive processing, and social processing. According to our results, higher levels of inquiry were associated with an increase in the relative frequency of episodes where students were engaged in proposing ideas versus asking and answering each others' questions. Higher levels of inquiry also favored episodes in which experimental work was approached in a more exploratory (versus procedural) manner. However, no major changes were observed in the extent to which students were engaged in either interpretive discussions of central scientific concepts and ideas. As part of our study we were also interested in characterizing the effects of experiments involving different levels of inquiry on the structure and adequacy of university general chemistry students' written arguments, as well as on the nature of their reflections about laboratory work. Our findings indicate that the level of inquiry of the observed experiments had no significant impact on the structure or adequacy of arguments generated by students. However, the level of inquiry of the experiments seemed to have a major impact on several areas of students' written reflections about laboratory work. In general, our results elicit trends and highlight issues that can help instructors and curriculum developers identify strategies to better support and scaffold productive engagement in the laboratory. Our results suggest that careful design and implementation of instructional interventions may be needed to maximize the learning effects of the more open-ended inquiry activities at the college level.
NASA Astrophysics Data System (ADS)
S-C Tai, Susan; Duewer, David L.
2010-01-01
Hormones are chemical messengers that regulate many life functions. Deviations from normal hormone levels can have serious health consequences. Accurate measurement of hormone levels in serum can be beneficial in diagnosing, monitoring, and treating a number of diseases. Two steroid hormones, cortisol and progesterone, were selected by the Organic Analysis Working Group (OAWG) to evaluate its member Institutes' measurement capabilities for this important class of measurand. Serum concentrations of cortisol range from 30 ng/mL to 230 ng/mL. Serum concentrations of progesterone in adult females range from 0.15 ng/mL to 25 ng/mL but can rise to approx230 ng/mL during pregnancy. The ability to measure cortisol is indicative of a laboratory's ability to measure steroid hormones at concentration levels similar to cortisol. The ability to measure progesterone is indicative of a laboratory's ability to measure steroid hormones with similar functional groups and concentration levels, such as testosterone. Pilot studies CCQM-P77.a and CCQM-P77.b on the determination of cortisol and progesterone in human serum were completed in 2006. There was good agreement among the results reported by participants who used isotope dilution/mass spectrometry (ID/MS) with either gas chromatography (GC) or liquid chromatography (LC). In 2007 the OAWG decided to proceed with key comparison (KC) CCQM-K63.a, cortisol in human serum, and CCQM-K63.b, progesterone in human serum. Thus, following established OAWG procedure, only results from participants that (1) used an ID/MS-based method, (2) participated in the relevant pilot study, and (3) used a metrologically traceable primary standard were to be eligible for use in calculating the key comparison reference value (KCRV) for each measurand. Six laboratories participated in CCQM-K63.a and eight laboratories participated in CCQM-K63.b. The same pooled frozen female serum material was used in both of the KCs. The mean value for the six ID/MS-based cortisol results is 100.4 ng/g with a relative standard deviation (%RSD) of 1.1%. The mean value for the seven ID/MS-based progesterone originally reported results is 2.83 with a %RSD of 1.8%. While a number of the reported results were not eligible to be used in establishing the KCRVs, the KCRVs as estimated from just the eligible results agree very well with these means. The excellent among-participant agreement indicates that ID/MS-based measurement procedures can provide precise and true results for steroid hormones at levels greater than about 1 ng/g. The progesterone result reported by a laboratory using a non-isotopically labelled internal standard was about 11% larger than the KCRV. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
2016 Los Alamos National Laboratory Hazardous Waste Minimization Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salzman, Sonja L.; English, Charles Joe
Waste minimization and pollution prevention are goals within the operating procedures of Los Alamos National Security, LLC (LANS). The US Department of Energy (DOE), inclusive of the National Nuclear Security Administration (NNSA) and the Office of Environmental Management, and LANS are required to submit an annual hazardous waste minimization report to the New Mexico Environment Department (NMED) in accordance with the Los Alamos National Laboratory (LANL or the Laboratory) Hazardous Waste Facility Permit. The report was prepared pursuant to the requirements of Section 2.9 of the LANL Hazardous Waste Facility Permit. This report describes the hazardous waste minimization program, whichmore » is a component of the overall Pollution Prevention (P2) Program, administered by the Environmental Stewardship Group (EPC-ES). This report also supports the waste minimization and P2 goals of the Associate Directorate of Environmental Management (ADEM) organizations that are responsible for implementing remediation activities and describes its programs to incorporate waste reduction practices into remediation activities and procedures. This report includes data for all waste shipped offsite from LANL during fiscal year (FY) 2016 (October 1, 2015 – September 30, 2016). LANS was active during FY2016 in waste minimization and P2 efforts. Multiple projects were funded that specifically related to reduction of hazardous waste. In FY2016, there was no hazardous, mixed-transuranic (MTRU), or mixed low-level (MLLW) remediation waste shipped offsite from the Laboratory. More non-remediation hazardous waste and MLLW was shipped offsite from the Laboratory in FY2016 compared to FY2015. Non-remediation MTRU waste was not shipped offsite during FY2016. These accomplishments and analysis of the waste streams are discussed in much more detail within this report.« less
Croatian survey on critical results reporting
Trifunović, Jasenka; Pavosevic, Tihana; Nikolac, Nora
2015-01-01
Introduction Poor harmonization of critical results management is present in various laboratories and countries, including Croatia. We aimed to investigate procedures used in critical results reporting in Croatian medical biochemistry laboratories (MBLs). Materials and methods An anonymous questionnaire, consisting of 24 questions/statements, related to critical results reporting procedures, was send to managers of MBLs in Croatia. Participants were asked to declare the frequency of performing procedures and degree of agreement with statements about critical values reporting using a Likert scale. Total score and mean scores for corresponding separate statements divided according to health care setting were calculated and compared. Results Responses from 111 Croatian laboratories (48%) were analyzed. General practice laboratories (GPLs) more often re-analyzed the sample before reporting the critical result in comparison with the hospital laboratories (HLs) (score: 4.86 (4.75-4.96) vs. 4.49 (4.25-4.72); P = 0.001) and more often reported the critical value exclusively to the responsible physician compared to HLs (4.46 (4.29-4.64) vs. 3.76 (3.48-4.03), P < 0.001). High total score (4.69 (4.56-4.82)) was observed for selection of the critical results list issued by the Croatian Chamber of Medical Biochemistry (CCMB) indicating a high harmonization level for this aspect of critical result management. Low total scores were observed for the statements regarding data recording and documentation of critical result notification. Conclusions Differences in practices about critical results reporting between HLs and GPLs were found. The homogeneity of least favorable responses detected for data recording and documentation of critical results notification reflects the lack of specific national recommendations. PMID:26110031
Pilot-Reported Beta-Blockers Identified by Forensic Toxicology Analysis of Postmortem Specimens.
Canfield, Dennis V; Dubowski, Kurt M; Whinnery, James M; Forster, Estrella M
2018-01-01
This study compared beta-blockers reported by pilots with the medications found by postmortem toxicology analysis of specimens received from fatal aviation accidents between 1999 and 2015. Several studies have compared drugs using the standard approach: Compare the drug found by toxicology analysis with the drug reported by the pilot. This study uniquely examined first the pilot-reported medication and then compared it to that detected by toxicology analysis. This study will serve two purposes: (i) to determine the capability of a toxicology laboratory to detect reported medications, and (ii) to identify pilots with medications below detectable limits. All information required for this study was extracted from the Toxicology Data Base system and was searched using ToxFlo or SQL Server Management Studio. The following information was collected and analyzed: pilot-reported trade and/or generic drug, date specimens received, time of accident, type of aviation operations (CFR), state, pilot level, age, class of medical, specimen type, specimen concentration, dose reported, frequency reported associated with the accident, quantity reported, National Transportation Safety Board (NTSB) accident event number, and all NTSB reports. There were 319 pilots that either reported taking a beta-blocker or were found to be taking a beta-blocker by postmortem toxicology analysis. Time of death, therapeutic concentration and specimen type were found to be factors in the ability of the laboratory to detect beta-blockers. Beta-blockers taken by pilots will, in most cases, be found by a competent postmortem forensic toxicology laboratory at therapeutic concentrations. The dose taken by the pilot was not found to be a factor in the ability of the laboratory to identify beta-blockers. Time of dose, route of administration, specimen tested and therapeutic concentration of the drug were found to be factors in the ability of the laboratory to identify beta-blockers in postmortem specimens. Published by Oxford University Press 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.
The School Performance of Post-H. Influenza Meningitic Children. Final Report.
ERIC Educational Resources Information Center
Pate, John E.
Reported was a project studying the school performance of children who had survived laboratory confirmed Haemophilus influenza meningitis prior to 4 years of age without observable sequelae and who were enrolled in regular primary grades. Thirty-nine index children were matched with controls by age, sex, socioeconomic level, and classroom…
State of the research environment - 2013
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phillips, Julia Mae; Simmons, Jerry Alvon; Weaver, Karla
2014-02-01
This report describes the condition of the research environment at Sandia National Laboratories and outlines key environment improvement activities undertaken by the Office of the Chief Technology Officer and the Sandia Research Leadership Team during fiscal year 2013. The report also outlines Lab-level objectives related to the research environment for fiscal year 2014.
Timeliness “at a glance”: assessing the turnaround time through the six sigma metrics.
Ialongo, Cristiano; Bernardini, Sergio
2016-01-01
Almost thirty years of systematic analysis have proven the turnaround time to be a fundamental dimension for the clinical laboratory. Several indicators are to date available to assess and report quality with respect to timeliness, but they sometimes lack the communicative immediacy and accuracy. The six sigma is a paradigm developed within the industrial domain for assessing quality and addressing goal and issues. The sigma level computed through the Z-score method is a simple and straightforward tool which delivers quality by a universal dimensionless scale and allows to handle non-normal data. Herein we report our preliminary experience in using the sigma level to assess the change in urgent (STAT) test turnaround time due to the implementation of total automation. We found that the Z-score method is a valuable and easy to use method for assessing and communicating the quality level of laboratory timeliness, providing a good correspondence with the actual change in efficiency which was retrospectively observed.
[A case of GH and TSH secreting pituitary macroadenoma].
Gołkowski, Filip; Buziak-Bereza, Monika; Stefańska, Agnieszka; Trofimiuk, Małgorzata; Pantofliński, Jacek; Huszno, Bohdan; Czepko, Ryszard; Adamek, Dariusz
2006-01-01
A case of GH and TSH secreting pituitary macroadenoma is reported. A 45-year-old female presented clinical features of acromegaly (the abnormal growth of the hands and feet, with lower jaw protrusion), diabetes mellitus, hypertension, nodular goiter and hyperthyroidism of unclear origin. NMR pituitary imaging revealed intra and extrasellar tumor. The laboratory examinations showed very high plasma levels of GH and IGF-1 and normal level of TSH coexisting with high plasma levels of free thyroid hormones. Pharmacological pretreatment with somatostatin analogues caused the substantial reduction of GH and TSH plasma levels. Histological and immunohistochemical examination of the tissue obtained at transsphenoidal surgery showed GH and TSH secreting adenoma. The laboratory examinations after surgery showed normal GH and IGF-1 plasma levels and reduced insulin requirement, what indicates radical operation. The very low plasma levels of TSH and free thyroid hormones after surgery and immunohistochemical examination suggest central hyperthyroidism due to TSH secreting pituitary tumor (thyrotropinoma).
Benchmarking in pathology: development of an activity-based costing model.
Burnett, Leslie; Wilson, Roger; Pfeffer, Sally; Lowry, John
2012-12-01
Benchmarking in Pathology (BiP) allows pathology laboratories to determine the unit cost of all laboratory tests and procedures, and also provides organisational productivity indices allowing comparisons of performance with other BiP participants. We describe 14 years of progressive enhancement to a BiP program, including the implementation of 'avoidable costs' as the accounting basis for allocation of costs rather than previous approaches using 'total costs'. A hierarchical tree-structured activity-based costing model distributes 'avoidable costs' attributable to the pathology activities component of a pathology laboratory operation. The hierarchical tree model permits costs to be allocated across multiple laboratory sites and organisational structures. This has enabled benchmarking on a number of levels, including test profiles and non-testing related workload activities. The development of methods for dealing with variable cost inputs, allocation of indirect costs using imputation techniques, panels of tests, and blood-bank record keeping, have been successfully integrated into the costing model. A variety of laboratory management reports are produced, including the 'cost per test' of each pathology 'test' output. Benchmarking comparisons may be undertaken at any and all of the 'cost per test' and 'cost per Benchmarking Complexity Unit' level, 'discipline/department' (sub-specialty) level, or overall laboratory/site and organisational levels. We have completed development of a national BiP program. An activity-based costing methodology based on avoidable costs overcomes many problems of previous benchmarking studies based on total costs. The use of benchmarking complexity adjustment permits correction for varying test-mix and diagnostic complexity between laboratories. Use of iterative communication strategies with program participants can overcome many obstacles and lead to innovations.
EML Gamma Spectrometry Data Evaluation Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Decker, Karin M.
2001-01-01
This report presents the results of the analyses for the third EML Gamma Spectrometry Data Evaluation Program (October 1999). This program assists laboratories in providing more accurate gamma spectra analysis results and provides a means for users of gamma data to assess how a laboratory performed on various types of gamma spectrometry analyses. This is accomplished through the use of synthetic gamma spectra. A calibration spectrum, a background spectrum, and three sample spectra are sent to each participant in the spectral file format requested by the laboratory. The calibration spectrum contains nuclides covering the energy range from 59.5 keV tomore » 1836 keV. The participants are told fallout and fission product nuclides could be present. The sample spectra are designed to test the ability of the software and user to properly resolve multiplets and to identify and quantify nuclides in a complicated fission product spectrum. The participants were asked to report values and uncertainties as Becquerel per sample with no decay correction. Thirty-one sets of results were reported from a total of 60 laboratories who received the spectra. Six foreign laboratories participated. The percentage of the results within 1 of the expected value was 68, 33, and 46 for samples 1, 2, and 3, respectively. From all three samples, 18% of the results were more than 3 from the expected value. Eighty-three (12%) values out of a total of 682 expected results were not reported for the three samples. Approximately 30% of these false negatives were due the laboratories not reporting 144Pr in sample 2 which was present at the minimum detectable activity level. There were 53 false positives reported with 25% of these responses due to problems with background subtraction. The results show improvement in the ability of the software or user to resolve peaks separated by 1 keV. Improvement is still needed either in the analysis report produced by the software or in the review of these results by the users.« less
Ames Laboratory site environmental report, calendar year 1988
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mathison, L.K.
1989-05-01
The summarized data and conclusions from the Ames Laboratory environmental monitoring program are presented in this Annual Site Environmental Report. Ames Laboratory is located on the campus of Iowa State University (ISU) and occupies several buildings owned by the Department of Energy. A study is being conducted to identify environmental sampling methods which can characterize and separate the impact of Ames Laboratory's campus activities and that of ISU. This will enable the Laboratory to determine what possible impact it's operations may be having to the environment, if any. Two Pollution Abatement projects were begun in 1988. They were: removal ofmore » thorium contaminated soil resulting from a historical release of thorium at the Laboratory, to the Ames, Iowa Water Pollution Control (sewage) Plant and demolition of a small Blockhouse'' constructed of concrete block which had been used for low level radioactive waste handling. The contaminated soil has been removed and transported to Hanford, WA for disposal. A final site radiological survey for thorium is pending. In addition, contaminated debris was transported to Hanford, WA for disposal and a final site survey is pending. 7 refs., 4 figs., 1 tab.« less
Lowe, Gary R; Griffin, Yolanda; Hart, Michael D
2014-08-01
Modern electronic health record systems (EHRS) reportedly offer advantages including improved quality, error prevention, cost reduction, and increased efficiency. This project reviewed the impact on specimen turnaround times (TAT) and percent compliance for specimens processed in a STAT laboratory after implementation of an upgraded EHRS. Before EHRS implementation, laboratory personnel received instruction and training for specimen processing. One laboratory member per shift received additional training. TAT and percent compliance data sampling occurred 4 times monthly for 13 months post-conversion and were compared with the mean of data collected for 3 months pre-conversion. Percent compliance was gauged using a benchmark of reporting 95% of all specimens within 7 min from receipt. Control charts were constructed for TAT and percent compliance with control limits set at 2 SD and applied continuously through the data collection period. TAT recovered to pre-conversion levels by the 6th month post-conversion. Percent compliance consistently returned to pre-conversion levels by the 10th month post-conversion. Statistical analyses revealed the TAT were significantly longer for 3 months post-conversion (P < .001) compared with pre-conversion levels. Statistical significance was not observed for subsequent groups. Percent compliance results were significantly lower for 6 months post-conversion (P < .001). Statistical significance was not observed for subsequent groups. Extensive efforts were made to train and prepare personnel for challenges expected after the EHRS upgrade. Specific causes identified with the upgraded EHRS included multiple issues involving personnel and the EHRS. These data suggest that system and user issues contributed to delays in returning to pre-conversion TAT and percent compliance levels following the upgrade in the EHRS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Quirk, W.J.; Canada, J.; de Vore, L.
This monthly report of research activities at Lawrence Livermore Laboratory highlights three different research programs. First, the Forensic Science Center supports a broad range of analytical techniques that focus on detecting and analyzing chemical, biological, and nuclear species. Analyses are useful in the areas of nonproliferation, counterterrorism, and law enforcement. Second, starting in 1977, the laboratory initiated a series of studies to understand a high incidence of melanoma among employees. Continued study shows that mortality from this disease has decreased from the levels seen in the 1980`s. Third, to help coordinate the laboratory`s diverse research projects that can provide bettermore » healthcare tools to the public, the lab is creating the new Center for Healthcare Technologies.« less
Beach, Dale L; Alvarez, Consuelo J
2015-12-01
Synthetic biology offers an ideal opportunity to promote undergraduate laboratory courses with research-style projects, immersing students in an inquiry-based program that enhances the experience of the scientific process. We designed a semester-long, project-based laboratory curriculum using synthetic biology principles to develop a novel sensory device. Students develop subject matter knowledge of molecular genetics and practical skills relevant to molecular biology, recombinant DNA techniques, and information literacy. During the spring semesters of 2014 and 2015, the Synthetic Biology Laboratory Project was delivered to sophomore genetics courses. Using a cloning strategy based on standardized BioBrick genetic "parts," students construct a "reporter plasmid" expressing a reporter gene (GFP) controlled by a hybrid promoter regulated by the lac-repressor protein (lacI). In combination with a "sensor plasmid," the production of the reporter phenotype is inhibited in the presence of a target environmental agent, arabinose. When arabinose is absent, constitutive GFP expression makes cells glow green. But the presence of arabinose activates a second promoter (pBAD) to produce a lac-repressor protein that will inhibit GFP production. Student learning was assessed relative to five learning objectives, using a student survey administered at the beginning (pre-survey) and end (post-survey) of the course, and an additional 15 open-ended questions from five graded Progress Report assignments collected throughout the course. Students demonstrated significant learning gains (p < 0.05) for all learning outcomes. Ninety percent of students indicated that the Synthetic Biology Laboratory Project enhanced their understanding of molecular genetics. The laboratory project is highly adaptable for both introductory and advanced courses.
Pérez-Edgar, Koraly; Schmidt, Louis A.; Henderson, Heather A.; Schulkin, Jay; Fox, Nathan A.
2008-01-01
SUMMARY Behavioral problems in young children can take on a variety of forms, which are linked to distinct antecedents and co-occurring markers. Internalizing difficulties in young children, for example, have been linked to individual differences in infant temperament and cortisol levels. In addition, there is growing evidence that these biobehavioral mechanisms are also shaped by gender. Four-year-old children participated in a study examining the relations between salivary cortisol and behavioral maladjustment as a function of gender and temperament. Both longitudinal (maternal report of infant temperament at 9 months) and concurrent (morning salivary cortisol at age 4) data were used to predict two forms of maladjustment: ‘Withdrawal’ (maternal report of internalizing behavior and laboratory observation of social reticence) and ‘Acting Out’ (maternal report of externalizing behavior and laboratory observation of solitary active play). High basal cortisol levels were strongly associated with Withdrawal in male participants. However, the relation was significant only in boys who exhibited high levels of negative temperament in infancy. There were no comparable findings with ‘Acting Out’ beyond a main effect of gender reflecting greater difficulty in boys. The data suggested that there are unique biobehavioral mechanisms shaping specific patterns of maladjustment in childhood. PMID:18650023
ERIC Educational Resources Information Center
Parrott, Annette
2000-01-01
Introduces a 2-day laboratory experiment on scientific inquiry and the environment. Studies antlion classification and investigates anatomy, habitat, life cycle, behavior, and other properties of antlions. Adapted for different grade levels and includes a scientific journal report. (YDS)
We report on a series of field and laboratory mesocosm experiments where we examined the effects of two levels of decomposing Ulva on Spartina alterniflora growth, soil biogeochemistry, and nitrogen dynamics. Monitoring of porewater revealed rapid mineralization to ammonium from...
External quality assessment on detection of hepatitis C virus RNA in clinical laboratories of China.
Wang, Lu-nan; Zhang, Rui; Shen, Zi-yu; Chen, Wen-xiang; Li, Jin-ming
2008-06-05
As with many studies carried out in European countries, a quality assurance program has been established by the National Center for Clinical Laboratories in China (NCCL). The results showed that the external quality assessment significantly improves laboratory performance for quantitative evaluation of hepatitis C virus (HCV) RNA. Serum panels were delivered twice annually to the clinical laboratories which performed HCV RNA detection in China. Each panel made up of 5 coded samples. All laboratories were requested to carry out the detection within the required time period and report on testing results which contained qualitative and/or quantitative test findings, reagents used and relevant information about apparatus. All the positive samples were calibrated against the first International Standard for HCV RNA in a collaborative study and the range of comparison target value (TG) designated as +/- 0.5 log. The numbers of laboratories reporting on qualitative testing results for the first and second time external quality assessment were 168 and 167 in the year of 2003 and increased to 209 and 233 in 2007; the numbers of laboratories reporting on quantitative testing results were 134 and 147 in 2003 and rose to 340 and 339 in 2007. Deviation between the mean value for quantitative results at home in 2003 and the target value was above 0.5 log, which was comparatively high. By 2007, the target value was close to the national average except for the low concentrated specimens (10(3) IU/ml). The percentage of results within the range of GM +/- 0.5 log(10) varied from 8.2% to 93.5%. Some laboratories had some difficulties in the exact quantification of the lowest (3.00 log IU/ml) as well as of the highest viral levels (6.37 log IU/ml) values, very near to the limits of the dynamic range of the assays. The comparison of these results with the previous study confirms that a regular participation in external quality assessment (EQA) assures the achievement of a high proficiency level in the diagnosis of HCV infection. During the 5-year external quality assessment, sensitivity and accuracy of detection in most of the clinical laboratories have been evidently improved and the quality of kits has also been substantially improved.
Gray QB-sing-faced version 2 (SF2) open environment test report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Plummer, J.; Immel, D.; Bobbitt, J.
This report details the design upgrades incorporated into the new version of the GrayQbTM SF2 device and the characterization testing of this upgraded device. Results from controlled characterization testing in the Savannah River National Laboratory (SRNL) R&D Engineering Imaging and Radiation Lab (IRL) and the Savannah River Site (SRS) Health Physics Instrument Calibration Laboratory (HPICL) is presented, as well as results from the open environment field testing performed in the E-Area Low Level Waste Storage Area. Resultant images presented in this report were generated using the SRNL developed Radiation Analyzer (RAzerTM) software program which overlays the radiation contour images ontomore » the visual image of the location being surveyed.« less
NASA Astrophysics Data System (ADS)
Avison, Janine; Barham, Richard
2014-01-01
This document and the accompanying spreadsheets constitute the final report for key comparison CCAUV.A-K5 on the pressure calibration of laboratory standard microphones in the frequency range from 2 Hz to 10 kHz. Twelve national measurement institutes took part in the key comparison and the National Physical Laboratory piloted the project. Two laboratory standard microphones IEC type LS1P were circulated to the participants and results in the form of regular calibration certificates were collected throughout the project. One of the microphones was subsequently deemed to have compromised stability for the purpose of deriving a reference value. Consequently the key comparison reference value (KCRV) has been made based on the weighted mean results for sensitivity level and for sensitivity phase from just one of the microphones. Corresponding degrees of equivalence (DoEs) have also been calculated and are presented. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Hall, Miquette; Chattaway, Marie A.; Reuter, Sandra; Savin, Cyril; Strauch, Eckhard; Carniel, Elisabeth; Connor, Thomas; Van Damme, Inge; Rajakaruna, Lakshani; Rajendram, Dunstan; Jenkins, Claire; Thomson, Nicholas R.
2014-01-01
The genus Yersinia is a large and diverse bacterial genus consisting of human-pathogenic species, a fish-pathogenic species, and a large number of environmental species. Recently, the phylogenetic and population structure of the entire genus was elucidated through the genome sequence data of 241 strains encompassing every known species in the genus. Here we report the mining of this enormous data set to create a multilocus sequence typing-based scheme that can identify Yersinia strains to the species level to a level of resolution equal to that for whole-genome sequencing. Our assay is designed to be able to accurately subtype the important human-pathogenic species Yersinia enterocolitica to whole-genome resolution levels. We also report the validation of the scheme on 386 strains from reference laboratory collections across Europe. We propose that the scheme is an important molecular typing system to allow accurate and reproducible identification of Yersinia isolates to the species level, a process often inconsistent in nonspecialist laboratories. Additionally, our assay is the most phylogenetically informative typing scheme available for Y. enterocolitica. PMID:25339391
ERIC Educational Resources Information Center
Palmer, Jackie; Powell, Mary Jo
The Laboratory Network Program and the National Network of Eisenhower Mathematics and Science Regional Consortia, operating as the Curriculum Frameworks Task Force, jointly convened a group of educators involved in implementing state-level mathematics or science curriculum frameworks (CF). The Hilton Head (South Carolina) conference had a dual…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fox, K. M.; Edwards, T. B.; Caldwell, M. E.
In this report, the Savannah River National Laboratory (SRNL) provides chemical analyses and Product Consistency Test (PCT) results for a series of simulated high-level waste glass compositions fabricated by the Pacific Northwest National Laboratory (PNNL). These data will be used in the development of improved models for the prediction of nepheline crystallization in support of the Hanford Tank Waste Treatment and Immobilization Plant (WTP).
2013-09-27
Electronic reporting of laboratory results to public health agencies can improve public health surveillance for reportable diseases and conditions by making reporting more timely and complete. Since 2010, CDC has provided funding to 57 state, local, and territorial health departments through the Epidemiology and Laboratory Capacity for Infectious Diseases cooperative agreement to assist with improving electronic laboratory reporting (ELR) from clinical and public health laboratories to public health agencies. As part of this agreement, CDC and state and large local health departments are collaborating to monitor ELR implementation in the United States by developing data from each jurisdiction regarding total reporting laboratories, laboratories sending ELR by disease category and message format, and the number of ELR laboratory reports compared with the total number of laboratory reports. At the end of July 2013, 54 of the 57 jurisdictions were receiving at least some laboratory reports through ELR, and approximately 62% of 20 million laboratory reports were being received electronically, compared with 54% in 2012. Continued progress will require collaboration between clinical laboratories, laboratory information management system (LIMS) vendors, and public health agencies.
Kimman, Tjeerd G.; Smit, Eric; Klein, Michèl R.
2008-01-01
We examined the available evidence on the effectiveness of measures aimed at protecting humans and the environment against the risks of working with genetically modified microorganisms (GMOs) and with non-GMO pathogenic microorganisms. A few principles and methods underlie the current biosafety practice: risk assessment, biological containment, concentration and enclosure, exposure minimization, physical containment, and hazard minimization. Many of the current practices are based on experience and expert judgment. The effectiveness of biosafety measures may be evaluated at the level of single containment equipment items and procedures, at the level of the laboratory as a whole, or at the clinical-epidemiological level. Data on the containment effectiveness of equipment and laboratories are scarce and fragmented. Laboratory-acquired infections (LAIs) are therefore important for evaluating the effectiveness of biosafety. For the majority of LAIs there appears to be no direct cause, suggesting that failures of biosafety were not noticed or that containment may have been insufficient. The number of reported laboratory accidents associated with GMOs is substantially lower than that of those associated with non-GMOs. It is unknown to what extent specific measures contribute to the overall level of biosafety. We therefore recommend that the evidence base of biosafety practice be strengthened. PMID:18625678
Kimman, Tjeerd G; Smit, Eric; Klein, Michèl R
2008-07-01
We examined the available evidence on the effectiveness of measures aimed at protecting humans and the environment against the risks of working with genetically modified microorganisms (GMOs) and with non-GMO pathogenic microorganisms. A few principles and methods underlie the current biosafety practice: risk assessment, biological containment, concentration and enclosure, exposure minimization, physical containment, and hazard minimization. Many of the current practices are based on experience and expert judgment. The effectiveness of biosafety measures may be evaluated at the level of single containment equipment items and procedures, at the level of the laboratory as a whole, or at the clinical-epidemiological level. Data on the containment effectiveness of equipment and laboratories are scarce and fragmented. Laboratory-acquired infections (LAIs) are therefore important for evaluating the effectiveness of biosafety. For the majority of LAIs there appears to be no direct cause, suggesting that failures of biosafety were not noticed or that containment may have been insufficient. The number of reported laboratory accidents associated with GMOs is substantially lower than that of those associated with non-GMOs. It is unknown to what extent specific measures contribute to the overall level of biosafety. We therefore recommend that the evidence base of biosafety practice be strengthened.
NASA Astrophysics Data System (ADS)
Johnston, Marty; Jalkio, Jeffrey
2013-04-01
By the time students have reached the intermediate level physics courses they have been exposed to a broad set of analytical, experimental, and computational skills. However, their ability to independently integrate these skills into the study of a physical system is often weak. To address this weakness and assess their understanding of the underlying physical concepts we have introduced laboratory homework into lecture based, junior level theoretical mechanics and electromagnetics courses. A laboratory homework set replaces a traditional one and emphasizes the analysis of a single system. In an exercise, students use analytical and computational tools to predict the behavior of a system and design a simple measurement to test their model. The laboratory portion of the exercises is straight forward and the emphasis is on concept integration and application. The short student reports we collect have revealed misconceptions that were not apparent in reviewing the traditional homework and test problems. Work continues on refining the current problems and expanding the problem sets.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bartholomay, R.C.; Edwards, D.D.; Campbell, L.J.
1994-11-01
The U.S. Geological Survey and the Idaho Department of Water Resources, in response to a request from the U.S. Department of Energy, sampled 18 sites as part of a long-term project to monitor water quality of the Snake River Plain aquifer from the southern boundary of the Idaho National Engineering Laboratory to the Hagerman area. Water samples were collected and analyzed for selected radionuclides, inorganic constituents, organic compounds, and bacteria. The samples were collected from 13 irrigation wells, 1 domestic well, 1 spring, 2 stock wells, and 1 public supply well. Quality assurance samples also were collected and analyzed. Nonemore » of the samples analyzed for radionuclides, inorganic constituents, or organic compounds exceeded the established maximum contaminant levels for drinking water. Most of the radionuclide and inorganic constituent concentrations exceeded their respective reporting levels. Most of the samples analyzed for surfactants and dissolved organic carbon had concentrations that exceeded their reporting levels. None of the samples contained reportable concentrations of purgeable organic compounds or pesticides. Total coliform bacteria was present in nine samples.« less
Dejoie, T; Ramos, E; Baron, S; Bach-Ngohou, K; Masson, D
2008-01-01
We report the case of a 2 year-old child presented to the emergency department following a seizure. The child was hypotonic and examination was unremarkable but laboratory tests confirmed a severe hypoglycaemia. The insulin level, inappropriately high for the glycemia and the peptide C undetectable suggested exogenous hyperinsulinism. We conclude that the hypoglycaemia was likely the result of Munchhausen syndrome by proxy. The specificity of two immunoassays used (Elecsys Roche and IRMA CisBio) for the synthetic analogues of insulin explains the discrepancy between the insulin levels obtained but was crucially useful to the approach of the cause of the hypoglycaemia.
Roy, Somak; Durso, Mary Beth; Wald, Abigail; Nikiforov, Yuri E; Nikiforova, Marina N
2014-01-01
A wide repertoire of bioinformatics applications exist for next-generation sequencing data analysis; however, certain requirements of the clinical molecular laboratory limit their use: i) comprehensive report generation, ii) compatibility with existing laboratory information systems and computer operating system, iii) knowledgebase development, iv) quality management, and v) data security. SeqReporter is a web-based application developed using ASP.NET framework version 4.0. The client-side was designed using HTML5, CSS3, and Javascript. The server-side processing (VB.NET) relied on interaction with a customized SQL server 2008 R2 database. Overall, 104 cases (1062 variant calls) were analyzed by SeqReporter. Each variant call was classified into one of five report levels: i) known clinical significance, ii) uncertain clinical significance, iii) pending pathologists' review, iv) synonymous and deep intronic, and v) platform and panel-specific sequence errors. SeqReporter correctly annotated and classified 99.9% (859 of 860) of sequence variants, including 68.7% synonymous single-nucleotide variants, 28.3% nonsynonymous single-nucleotide variants, 1.7% insertions, and 1.3% deletions. One variant of potential clinical significance was re-classified after pathologist review. Laboratory information system-compatible clinical reports were generated automatically. SeqReporter also facilitated quality management activities. SeqReporter is an example of a customized and well-designed informatics solution to optimize and automate the downstream analysis of clinical next-generation sequencing data. We propose it as a model that may envisage the development of a comprehensive clinical informatics solution. Copyright © 2014 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kruger, Albert A.; Piepel, Gregory F.; Landmesser, S. M.
2013-11-13
This report is the last in a series of currently scheduled reports that presents the results from the High Level Waste (HLW) glass formulation development and testing work performed at the Vitreous State Laboratory (VSL) of the Catholic University of America (CUA) and the development of IHLW property-composition models performed jointly by Pacific Northwest National Laboratory (PNNL) and VSL for the River Protection Project-Waste Treatment and Immobilization Plant (RPP-WTP). Specifically, this report presents results of glass testing at VSL and model development at PNNL for Product Consistency Test (PCT), one-percent crystal fraction temperature (T1%), electrical conductivity (EC), and viscosity ofmore » HLW glasses. The models presented in this report may be augmented and additional validation work performed during any future immobilized HLW (IHLW) model development work. Completion of the test objectives is addressed.« less
[Effects of the ISO 15189 accreditation on Nagoya University Hospital].
Yoshiko, Kenichi
2012-07-01
The Department of Clinical Laboratory, Nagoya University Hospital acquired ISO 15189 accreditation in November, 2009. The operation of our Quality Management System (QMS) was first surveyed in October, 2010. In this paper, we reported the activity for the preparation and operation of our QMS and the effects of ISO 15189 accreditation. We investigated the changes in the number and content on nonconformities, incident reports and complaints before and after accreditation as indicators to evaluate the effect of ISO 15189 accreditation. Post accreditation, the number of nonconformities and incident reports decreased, seeming to show an improvement of quality of the laboratory activity; however, the number of complaints increased. We identified the increase of complaints at the phlebotomy station. There had been some problems with blood sampling in the past, but it seemed that staff had a high level of concern regarding these problems at the phlebotomy station and took appropriate measures to resolve the complaints. We confirmed that the ISO 15189 accreditation was instrumental in the improvements of the safety and efficiency on laboratory works. However there was a problem that increase of overtime works to operate the QMS. We deal with development of a laboratory management system using IT recourses to solve the problem.
New Report Shines Light on Installed Costs and Deployment Barriers for
Laboratory (NREL) are making available the most detailed component and system-level cost breakdowns to date previously unknown soft costs for the first time. The report, titled "Installed Cost Benchmarks and interest in pairing distributed PV with storage, but there's a lack of publicly available cost data and
The Development of Modular Instructional Materials for Physics for One-Year Vocational Students.
ERIC Educational Resources Information Center
Parsons, Ralph
This report describes a project to develop and test a number of individualized vocational physics modules designed to be laboratory-oriented, written at the lowest reading level, and supplemented with audiovisual materials. The report includes descriptions of the procedures used to develop, pilot test, and disseminate the materials. Each of the…
External quality assessment of urine particle identification: a Northern European experience.
Kouri, Timo T; Makkonen, Pirjo
2015-11-01
External quality assessment (EQA) schemes for urinalysis have been provided by Labquality Ltd, the publicly owned EQA service provider in Finland, since the 1980s. In 2014, the scheme on urine particle identification had 329 participating laboratories, out of which 60% from 19 countries were outside Finland. Each of the four annual web-based rounds were distributed with four Sternheimer-stained images from a single patient sample, as viewed both by bright-field and phase-contrast optics. Participants reported classified categories either at the basic or at the advanced level. Participating laboratories received assessment of their analytical performance as compared to their peers, including reflections from clinical data and preanalytical detail of the specimen. In general, reporting of basic urine particles succeeded in the eight schemes during the years 2013-2014 as follows: red blood cells 82%-92%, white blood cells 82%-97%, squamous epithelial cells 92%-98%, casts 84%-94%, and small epithelial cells 73%-83% (minimum and maximum of expected or accepted reports). This basic level of differentiation is used in routine laboratory reports, or as verification of results produced by automated instruments. Considerable effort is needed to standardise national procedures and reporting formats, in order to improve the shown figures internationally. Future technologies may help to alleviate limitations created by single digital images. Despite improvements, degenerating cells and casts always exhibit intermediate forms creating disputable classifications. That is why assessment of performance should encompass justified acceptable categories into the assessed outcomes. Preanalytical and clinical detail provide essential added value to morphological findings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaudioso, Jennifer Marie
2006-02-01
Over 300 Asian life scientists were surveyed to provide insight into work with infectious agents. This report provides the reader with a more complete understanding of the current practices employed to study infectious agents by laboratories located in Asian countries--segmented by level of biotechnology sophistication. The respondents have a variety of research objectives and study over 60 different pathogens and toxins. Many of the respondents indicated that their work was hampered by lack of adequate resources and the difficulty of accessing critical resources. The survey results also demonstrate that there appears to be better awareness of laboratory biosafety issues comparedmore » to laboratory biosecurity. Perhaps not surprisingly, many of these researchers work with pathogens and toxins under less stringent laboratory biosafety and biosecurity conditions than would be typical for laboratories in the West.« less
Real-Time Surveillance of Infectious Diseases: Taiwan's Experience.
Jian, Shu-Wan; Chen, Chiu-Mei; Lee, Cheng-Yi; Liu, Ding-Ping
Integration of multiple surveillance systems advances early warning and supports better decision making during infectious disease events. Taiwan has a comprehensive network of laboratory, epidemiologic, and early warning surveillance systems with nationwide representation. Hospitals and clinical laboratories have deployed automatic reporting mechanisms since 2014 and have effectively improved timeliness of infectious disease and laboratory data reporting. In June 2016, the capacity of real-time surveillance in Taiwan was externally assessed and was found to have a demonstrated and sustainable capability. We describe Taiwan's disease surveillance system and use surveillance efforts for influenza and Zika virus as examples of surveillance capability. Timely and integrated influenza information showed a higher level and extended pattern of influenza activity during the 2015-16 season, which ensured prompt information dissemination and the coordination of response operations. Taiwan also has well-developed disease detection systems and was the first country to report imported cases of Zika virus from Miami Beach and Singapore. This illustrates a high level of awareness and willingness among health workers to report emerging infectious diseases, and highlights the robust and sensitive nature of Taiwan's surveillance system. These 2 examples demonstrate the flexibility of the surveillance systems in Taiwan to adapt to emerging infectious diseases and major communicable diseases. Through participation in the GHSA, Taiwan can more actively collaborate with national counterparts and use its expertise to strengthen global and regional surveillance capacity in the Asia Pacific and in Southeast Asia, in order to advance a world safe and secure from infectious disease.
Real-Time Surveillance of Infectious Diseases: Taiwan's Experience
Jian, Shu-Wan; Chen, Chiu-Mei; Lee, Cheng-Yi
2017-01-01
Integration of multiple surveillance systems advances early warning and supports better decision making during infectious disease events. Taiwan has a comprehensive network of laboratory, epidemiologic, and early warning surveillance systems with nationwide representation. Hospitals and clinical laboratories have deployed automatic reporting mechanisms since 2014 and have effectively improved timeliness of infectious disease and laboratory data reporting. In June 2016, the capacity of real-time surveillance in Taiwan was externally assessed and was found to have a demonstrated and sustainable capability. We describe Taiwan's disease surveillance system and use surveillance efforts for influenza and Zika virus as examples of surveillance capability. Timely and integrated influenza information showed a higher level and extended pattern of influenza activity during the 2015-16 season, which ensured prompt information dissemination and the coordination of response operations. Taiwan also has well-developed disease detection systems and was the first country to report imported cases of Zika virus from Miami Beach and Singapore. This illustrates a high level of awareness and willingness among health workers to report emerging infectious diseases, and highlights the robust and sensitive nature of Taiwan's surveillance system. These 2 examples demonstrate the flexibility of the surveillance systems in Taiwan to adapt to emerging infectious diseases and major communicable diseases. Through participation in the GHSA, Taiwan can more actively collaborate with national counterparts and use its expertise to strengthen global and regional surveillance capacity in the Asia Pacific and in Southeast Asia, in order to advance a world safe and secure from infectious disease. PMID:28418738
Human melatonin during continuous magnetic field exposure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Graham, C.; Cook, M.R.; Riffle, D.W.
This report describes the third in a series of double-blind, laboratory-based studies that were aimed at determining the effects of nocturnal exposure to power frequency magnetic fields on blood levels of melatonin in human volunteers. The two earlier studies evaluated effects on melatonin of intermittent exposure to 60 Hz circularly polarized magnetic fields at 10 and 200 mG. No overall effects on melatonin levels were found. In the present study, men were exposed continuously rather than intermittently through the night to the same 200 mG magnetic field condition that was used previously; again, no overall effects on melatonin levels weremore » found. The authors conclude that the intermittent and continuous exposure conditions used in the laboratory to date are not effective in altering nocturnal blood levels of melatonin in human volunteers.« less
NASA Technical Reports Server (NTRS)
Smith, J. L.
1980-01-01
Review comments of the Congressional report entitled 'Federal Policies to Promote the Widespread Utilization of Photovoltaic Systems' are presented. Responses to the review comments by the Jet Propulsion Laboratory, preparer of the Congressional report, are also presented. The Congressional report discussed various issues related to promoting the deployment of photovoltaic systems through the Federal Photovoltaic Program. Various program strategies and funding levels were examined.
Cake: Enabling High-level SLOs on Shared Storage Systems
2012-11-07
Cake: Enabling High-level SLOs on Shared Storage Systems Andrew Wang Shivaram Venkataraman Sara Alspaugh Randy H. Katz Ion Stoica Electrical...Date) * * * * * * * Professor R. Katz Second Reader (Date) Cake: Enabling High-level SLOs on Shared Storage Systems Andrew Wang, Shivaram Venkataraman ...Report MIT-LCS-TR-667, MIT, Laboratory for Computer Science, 1995. [39] A. Wang, S. Venkataraman , S. Alspaugh, I. Stoica, and R. Katz. Sweet storage SLOs
Richmond, Jonathan Y; Nesby-O'Dell, Shanna L
2002-12-06
In recent years, concern has increased regarding use of biologic materials as agents of terrorism, but these same agents are often necessary tools in clinical and research microbiology laboratories. Traditional biosafety guidelines for laboratories have emphasized use of optimal work practices, appropriate containment equipment, well-designed facilities, and administrative controls to minimize risk of worker injury and to ensure safeguards against laboratory contamination. The guidelines discussed in this report were first published in 1999 (U.S. Department of Health and Human Services/CDC and National Institutes of Health. Biosafety in microbiological and biomedical laboratories [BMBL]. Richmond JY, McKinney RW, eds. 4th ed. Washington, DC: US Department of Health and Human Services, 1999 [Appendix F]). In that report, physical security concerns were addressed, and efforts were focused on preventing unauthorized entry to laboratory areas and preventing unauthorized removal of dangerous biologic agents from the laboratory. Appendix F of BMBL is now being revised to include additional information regarding personnel risk assessments, and inventory controls. The guidelines contained in this report are intended for laboratories working with select agents under biosafety-level 2, 3, or 4 conditions as described in Sections II and III of BMBL. These recommendations include conducting facility risk assessments and developing comprehensive security plans to minimize the probability of misuse of select agents. Risk assessments should include systematic, site-specific reviews of 1) physical security; 2) security of data and electronic technology systems; 3) employee security; 4) access controls to laboratory and animal areas; 5) procedures for agent inventory and accountability; 6) shipping/transfer and receiving of select agents; 7) unintentional incident and injury policies; 8) emergency response plans; and 9) policies that address breaches in security. The security plan should be an integral part of daily operations. All employees should be well-trained and equipped, and the plan should be reviewed annually, at least.
Extra-analytical quality indicators and laboratory performances.
Sciacovelli, Laura; Aita, Ada; Plebani, Mario
2017-07-01
In the last few years much progress has been made in raising the awareness of laboratory medicine professionals about the effectiveness of quality indicators (QIs) in monitoring, and improving upon, performances in the extra-analytical phases of the Total Testing Process (TTP). An effective system for management of QIs includes the implementation of an internal assessment system and participation in inter-laboratory comparison. A well-designed internal assessment system allows the identification of critical activities and their systematic monitoring. Active participation in inter-laboratory comparison provides information on the performance level of one laboratory with respect to that of other participating laboratories. In order to guarantee the use of appropriate QIs and facilitate their implementation, many laboratories have adopted the Model of Quality Indicators (MQI) proposed by Working Group "Laboratory Errors and Patient Safety" (WG-LEPS) of IFCC, since 2008, which is the result of international consensus and continuous experimentation, and updating to meet new, constantly emerging needs. Data from participating laboratories are collected monthly and reports describing the statistical results and evaluating laboratory data, utilizing the Six Sigma metric, issued regularly. Although the results demonstrate that the processes need to be improved upon, overall the comparison with data collected in 2014 shows a general stability of quality levels and that an improvement has been achieved over time for some activities. The continuous monitoring of QI data allows identification all possible improvements, thus highlighting the value of participation in the inter-laboratory program proposed by WG-LEPS. The active participation of numerous laboratories will guarantee an ever more significant State-of-the-Art, promote the reduction of errors and improve quality of the TTP, thus guaranteeing patient safety. Copyright © 2017. Published by Elsevier Inc.
A global quantification of "normal" sleep schedules using smartphone data.
Walch, Olivia J; Cochran, Amy; Forger, Daniel B
2016-05-01
The influence of the circadian clock on sleep scheduling has been studied extensively in the laboratory; however, the effects of society on sleep remain largely unquantified. We show how a smartphone app that we have developed, ENTRAIN, accurately collects data on sleep habits around the world. Through mathematical modeling and statistics, we find that social pressures weaken and/or conceal biological drives in the evening, leading individuals to delay their bedtime and shorten their sleep. A country's average bedtime, but not average wake time, predicts sleep duration. We further show that mathematical models based on controlled laboratory experiments predict qualitative trends in sunrise, sunset, and light level; however, these effects are attenuated in the real world around bedtime. Additionally, we find that women schedule more sleep than men and that users reporting that they are typically exposed to outdoor light go to sleep earlier and sleep more than those reporting indoor light. Finally, we find that age is the primary determinant of sleep timing, and that age plays an important role in the variability of population-level sleep habits. This work better defines and personalizes "normal" sleep, produces hypotheses for future testing in the laboratory, and suggests important ways to counteract the global sleep crisis.
Beach, Dale L.; Alvarez, Consuelo J.
2015-01-01
Synthetic biology offers an ideal opportunity to promote undergraduate laboratory courses with research-style projects, immersing students in an inquiry-based program that enhances the experience of the scientific process. We designed a semester-long, project-based laboratory curriculum using synthetic biology principles to develop a novel sensory device. Students develop subject matter knowledge of molecular genetics and practical skills relevant to molecular biology, recombinant DNA techniques, and information literacy. During the spring semesters of 2014 and 2015, the Synthetic Biology Laboratory Project was delivered to sophomore genetics courses. Using a cloning strategy based on standardized BioBrick genetic “parts,” students construct a “reporter plasmid” expressing a reporter gene (GFP) controlled by a hybrid promoter regulated by the lac-repressor protein (lacI). In combination with a “sensor plasmid,” the production of the reporter phenotype is inhibited in the presence of a target environmental agent, arabinose. When arabinose is absent, constitutive GFP expression makes cells glow green. But the presence of arabinose activates a second promoter (pBAD) to produce a lac-repressor protein that will inhibit GFP production. Student learning was assessed relative to five learning objectives, using a student survey administered at the beginning (pre-survey) and end (post-survey) of the course, and an additional 15 open-ended questions from five graded Progress Report assignments collected throughout the course. Students demonstrated significant learning gains (p < 0.05) for all learning outcomes. Ninety percent of students indicated that the Synthetic Biology Laboratory Project enhanced their understanding of molecular genetics. The laboratory project is highly adaptable for both introductory and advanced courses. PMID:26753032
[Nurses' Innovation Acceptance of Barcode Technology].
Cheng, Hui-Ping; Lee, Ting-Ting; Liu, Chieh-Yu; Hou, I-Ching
2016-04-01
Healthcare organizations have increasingly adopted barcode technology to improve care quality and work efficiency. Barcode technology is simple to use, so it is frequently used in patient identification, medication administration, and specimen collection processes. This study used a technology acceptance model and innovation diffusion theory to explore the innovation acceptance of barcode technology by nurses. The data were collected using a structured questionnaire with open-ended questions that was based on the technology acceptance model and innovation diffusion theory. The questionnaire was distributed to and collected from 200 nurses from March to May 2014. Data on laboratory reporting times and specimen rejection rates were collected as well. Variables that were found to have a significant relationship (p<.001) with innovation acceptance included (in order of importance): perceived usefulness (r=.722), perceived ease of use (r=.720), observability (r=.579), compatibility (r=.364), and trialability (r=.344). N-level nurses demonstrated higher acceptance than their N1 and N2 level peers (F=3.95, p<.05). Further, the mean laboratory reporting time decreased 109 minutes (t=10.03, p<.05) and the mean specimen rejection rate decreased from 2.18% to 0.28%. The results revealed that barcode technology has been accepted by nurses and that this technology effectively decreases both laboratory reporting times and specimen rejection rates. However, network speed and workflow should be further improved in order to benefit clinical practice.
Annual Sustainability Report FY 2014. Incorporates NREL Site Sustainability Plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rukavina, Frank
NREL's Sustainability Program is responsible for upholding all executive orders, federal regulations, U.S. Department of Energy (DOE) orders, and goals related to sustainable and resilient facility operations. But NREL continues to expand sustainable practices above and beyond the laboratory's regulations and requirements to ensure that the laboratory fulfills its mission into the future, leaves the smallest possible legacy footprint, and models sustainable operations and behaviors on national, regional, and local levels. The report, per the GRI reporting format, elaborates on multi-year goals relative to executive orders, achievements, and challenges; and success stories provide specific examples. A section called 'Sustaining NREL'smore » Future Through Integration' provides insight into how NREL is successfully expanding the adoption of renewable energy technologies through integration.« less
Heindel, Jerrold J.; vom Saal, Frederick S.
2008-01-01
We report information from two workshops sponsored by the National Institutes of Health that were held to a) assess whether dietary estrogens could significantly impact end points in experimental animals, and b) involve program participants and feed manufacturers to address the problems associated with measuring and eliminating batch-to-batch variability in rodent diets that may lead to conflicting findings in animal experiments within and between laboratories. Data were presented at the workshops showing that there is significant batch-to-batch variability in estrogenic content of commercial animal diets, and that this variability results in differences in experimental outcomes. A combination of methods were proposed to determine levels of total estrogenic activity and levels of specific estrogenic constituents in soy-containing, casein-containing, and other soy-free rodent diets. Workshop participants recommended that researchers pay greater attention to the type of diet being used in animal studies and choose a diet whose estrogenic activity (or lack thereof) is appropriate for the experimental model and end points of interest. Information about levels of specific phytoestrogens, as well as estrogenic activity caused by other contaminants and measured by bioassay, should be disclosed in scientific publications. This will require laboratory animal diet manufacturers to provide investigators with information regarding the phytoestrogen content and other estrogenic compounds in commercial diets used in animal research. PMID:18335108
Levin-Rector, Alison; Nivin, Beth; Yeung, Alice; Fine, Annie D; Greene, Sharon K
2015-08-01
Timely outbreak detection is necessary to successfully control influenza in long-term care facilities (LTCFs) and other institutions. To supplement nosocomial outbreak reports, calls from infection control staff, and active laboratory surveillance, the New York City (NYC) Department of Health and Mental Hygiene implemented an automated building-level analysis to proactively identify LTCFs with laboratory-confirmed influenza activity. Geocoded addresses of LTCFs in NYC were compared with geocoded residential addresses for all case-patients with laboratory-confirmed influenza reported through passive surveillance. An automated daily analysis used the geocoded building identification number, approximate text matching, and key-word searches to identify influenza in residents of LTCFs for review and follow-up by surveillance coordinators. Our aim was to determine whether the building analysis improved prospective outbreak detection during the 2013-2014 influenza season. Of 119 outbreaks identified in LTCFs, 109 (92%) were ever detected by the building analysis, and 55 (46%) were first detected by the building analysis. Of the 5,953 LTCF staff and residents who received antiviral prophylaxis during the 2013-2014 season, 929 (16%) were at LTCFs where outbreaks were initially detected by the building analysis. A novel building-level analysis improved influenza outbreak identification in LTCFs in NYC, prompting timely infection control measures. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Heindel, Jerrold J; vom Saal, Frederick S
2008-03-01
We report information from two workshops sponsored by the National Institutes of Health that were held to a) assess whether dietary estrogens could significantly impact end points in experimental animals, and b) involve program participants and feed manufacturers to address the problems associated with measuring and eliminating batch-to-batch variability in rodent diets that may lead to conflicting findings in animal experiments within and between laboratories. Data were presented at the workshops showing that there is significant batch-to-batch variability in estrogenic content of commercial animal diets, and that this variability results in differences in experimental outcomes. A combination of methods were proposed to determine levels of total estrogenic activity and levels of specific estrogenic constituents in soy-containing, casein-containing, and other soy-free rodent diets. Workshop participants recommended that researchers pay greater attention to the type of diet being used in animal studies and choose a diet whose estrogenic activity (or lack thereof) is appropriate for the experimental model and end points of interest. Information about levels of specific phytoestrogens, as well as estrogenic activity caused by other contaminants and measured by bioassay, should be disclosed in scientific publications. This will require laboratory animal diet manufacturers to provide investigators with information regarding the phytoestrogen content and other estrogenic compounds in commercial diets used in animal research.
Bonn, Bernadine A.
2008-01-01
A long-term method detection level (LT-MDL) and laboratory reporting level (LRL) are used by the U.S. Geological Survey?s National Water Quality Laboratory (NWQL) when reporting results from most chemical analyses of water samples. Changing to this method provided data users with additional information about their data and often resulted in more reported values in the low concentration range. Before this method was implemented, many of these values would have been censored. The use of the LT-MDL and LRL presents some challenges for the data user. Interpreting data in the low concentration range increases the need for adequate quality assurance because even small contamination or recovery problems can be relatively large compared to concentrations near the LT-MDL and LRL. In addition, the definition of the LT-MDL, as well as the inclusion of low values, can result in complex data sets with multiple censoring levels and reported values that are less than a censoring level. Improper interpretation or statistical manipulation of low-range results in these data sets can result in bias and incorrect conclusions. This document is designed to help data users use and interpret data reported with the LTMDL/ LRL method. The calculation and application of the LT-MDL and LRL are described. This document shows how to extract statistical information from the LT-MDL and LRL and how to use that information in USGS investigations, such as assessing the quality of field data, interpreting field data, and planning data collection for new projects. A set of 19 detailed examples are included in this document to help data users think about their data and properly interpret lowrange data without introducing bias. Although this document is not meant to be a comprehensive resource of statistical methods, several useful methods of analyzing censored data are demonstrated, including Regression on Order Statistics and Kaplan-Meier Estimation. These two statistical methods handle complex censored data sets without resorting to substitution, thereby avoiding a common source of bias and inaccuracy.
Report formatting in laboratory medicine - a call for harmony.
Jones, Graham R D; Legg, Michael
2018-04-19
The results of medical laboratory testing are only useful if they lead to appropriate actions by medical practitioners and/or patients. An underappreciated component of the medical testing process is the transfer of the information from the laboratory report into the reader's brain. The format of laboratory reports can be determined by the testing laboratory, which may issue a formatted report, or by electronic systems receiving information from laboratories and controlling the report format. As doctors can receive information from many laboratories, interpreting information from reports in a safe and rapid manner is facilitated by having similar report layouts and formats. Using Australia as an example, there is a wide variation in report formats in spite of a body of work to define standards for reporting. In addition to standardising of report formats, consideration needs to be given to optimisation of report formatting to facilitate rapid and unambiguous reading of the report and also interpretation of the data. Innovative report formats have been developed by some laboratories; however, wide adoption has not followed. The need to balance uniformity of reporting with appropriate innovation is a challenge for safe reporting of laboratory results. This paper discusses the current status and opportunity for improvement in safety and efficiency of the reading of laboratory reports, using current practise and developments in Australia as examples.
Maysami, Samaneh; Wong, Raymond; Pradillo, Jesus M; Denes, Adam; Dhungana, Hiramani; Malm, Tarja; Koistinaho, Jari; Orset, Cyrille; Rahman, Mahbubur; Rubio, Marina; Schwaninger, Markus; Vivien, Denis; Bath, Philip M; Rothwell, Nancy J
2015-01-01
Stroke represents a global challenge and is a leading cause of permanent disability worldwide. Despite much effort, translation of research findings to clinical benefit has not yet been successful. Failure of neuroprotection trials is considered, in part, due to the low quality of preclinical studies, low level of reproducibility across different laboratories and that stroke co-morbidities have not been fully considered in experimental models. More rigorous testing of new drug candidates in different experimental models of stroke and initiation of preclinical cross-laboratory studies have been suggested as ways to improve translation. However, to our knowledge, no drugs currently in clinical stroke trials have been investigated in preclinical cross-laboratory studies. The cytokine interleukin 1 is a key mediator of neuronal injury, and the naturally occurring interleukin 1 receptor antagonist has been reported as beneficial in experimental studies of stroke. In the present paper, we report on a preclinical cross-laboratory stroke trial designed to investigate the efficacy of interleukin 1 receptor antagonist in different research laboratories across Europe. Our results strongly support the therapeutic potential of interleukin 1 receptor antagonist in experimental stroke and provide further evidence that interleukin 1 receptor antagonist should be evaluated in more extensive clinical stroke trials. PMID:26661169
Teaching Laboratory Renovation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Al-Zuhairi, Ali Jassim; Al-Dahhan, Wedad; Hussein, Falah
Scientists at universities across Iraq are actively working to report actual incidents and accidents occurring in their laboratories, as well as structural improvements made to improve safety and security, to raise awareness and encourage openness, leading to widespread adoption of robust Chemical Safety and Security (CSS) practices. The improvement of students’ understanding of concepts in science and its applications, practical scientific skills and understanding of how science and scientists work in laboratory experiences have been considered key aspects of education in science for over 100 years. Facility requirements for the necessary level of safety and security combined with specific requirementsmore » relevant to the course to be conducted dictate the structural design of a particular laboratory, and the design process must address both. This manuscript is the second in a series of five case studies describing laboratory incidents, accidents, and laboratory improvements. We summarize the process used to guide a major renovation of the chemistry instructional laboratory facilities at Al-Nahrain University and discuss lessons learned from the project.« less
NASA Astrophysics Data System (ADS)
Freedman, Michael P.
This study investigated the use of a hands-on laboratory program to improve attitudes toward science and increase achievement levels in science knowledge among students in a ninth grade physical science course. An objective final examination measured achievement in science knowledge, and a Q sort survey measured attitude toward science. A t test compared the groups' differences in achievement and attitude toward science. An analysis of covariance determined the effect of the laboratory treatment on the dependent variable, with attitude toward science as the covariable. The findings showed that students with regular laboratory instruction scored significantly higher (p < .05) on achievement in science knowledge than those without laboratory instruction, girls with regular laboratory instruction scored significantly higher (p < .05) on achievement in science knowledge than those without laboratory instruction, and girls and boys within the treatment group did not differ significantly on achievement in science knowledge. No significant differences were reported in attitude toward science between or within groups.
An inter-laboratory comparison study on transfer, persistence and recovery of DNA from cable ties.
Steensma, Kristy; Ansell, Ricky; Clarisse, Lindy; Connolly, Edward; Kloosterman, Ate D; McKenna, Louise G; van Oorschot, Roland A H; Szkuta, Bianca; Kokshoorn, Bas
2017-11-01
To address questions on the activity that led to the deposition of biological traces in a particular case, general information on the probabilities of transfer, persistence and recovery of cellular material in relevant scenarios is necessary. These figures may be derived from experimental data described in forensic literature when conditions relevant to the case were included. The experimental methodology regarding sampling, DNA extraction, DNA typing and profile interpretation that were used to generate these published data may differ from those applied in the case and thus the applicability of the literature data may be questioned. To assess the level of variability that different laboratories obtain when similar exhibits are analysed, we performed an inter-laboratory study between four partner laboratories. Five sets of 20 cable ties bound by different volunteers were distributed to the participating laboratories and sampled and processed according to the in-house protocols. Differences were found for the amount of retrieved DNA, as well as for the reportability and composition of the DNA profiles. These differences also resulted in different probabilities of transfer, persistence and recovery for each laboratory. Nevertheless, when applied to a case example, these differences resulted in similar assignments of weight of evidence given activity-level propositions. Copyright © 2017 Elsevier B.V. All rights reserved.
Development of a framework of quality assurance practices for a radon passive dosemeter service.
D'Alessandro, M; Leonardi, F; Tonnarini, S; Trevisi, R; Veschetti, M
2010-06-01
Etched track detectors are widely used for the detection of radon and its decay products. The reliability of radon measurement performed with such devices requires that laboratories producing analytical data are able to provide results of the required quality. The need for uniform results from laboratories at an international level therefore requires the implementation of a quality assurance programme, the harmonization of criteria, sampling procedures, calculations and the reporting of results, agreed on the basis of fundamental principles and international standards. The quality assurance programme described here is the first step on the way to ISO/IEC 17025 certification for the RI-RN (ISPESL) laboratory.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wallen, Robert B; Lambert, Scott R; Gevorgian, Vahan
This report details the commissioning of the 5-megawatt dynamometer at the National Wind Technology Center at the National Renewable Energy Laboratory. The purpose of these characterization tests were to verify the dynamometer's performance over the widest possible range of operating conditions, gain insight into system-level behavior, and establish confidence in measurement data.
ERIC Educational Resources Information Center
Adelson, Nancy C.; And Others
The Laboratory staff reported the unit development and field test activities in their effort to collect, analyze, synthesize, and disseminate new curriculum developments in secondary level social studies to school curriculum decision makers. The audience consisted primarily of social studies teachers and department chairmen. To further refine and…
Effect of the Level of Inquiry of Lab Experiments on General Chemistry Students' Written Reflections
ERIC Educational Resources Information Center
Xu, Haozhi; Talanquer, Vincente
2013-01-01
The central goal of this exploratory study was to characterize the effects of experiments involving different levels of inquiry on the nature of college students' written reflections about laboratory work. Data were collected in the form of individual lab reports written using a science writing heuristic template by a subset of the students…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bartholomay, R.C.; Williams, L.M.; Campbell, L.J.
1995-10-01
The US Geological Survey and the Idaho Department of Water Resources, in response to a request from the US Department of Energy, samples 18 sites as part of a long-term project to monitor water quality of the Snake River Plain aquifer from the southern boundary of the Idaho National Engineering Laboratory to the Hagerman area. Water samples were collected and analyzed for selected radionuclides, stable isotopes, inorganic constituents, and organic compounds. The samples were collected from seven irrigation wells, seven domestic wells, two springs, one stock well, and one observation well. Two quality assurance samples also were collected and analyzed.more » None of the radionuclide, inorganic constituent, or organic compound concentrations exceeded the established maximum contaminant levels for drinking water. Many of the radionuclide and inorganic constituent concentrations exceeded their respective reporting levels. All samples analyzed for dissolved organic carbon had concentrations that exceeded their minimum reporting levels.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bartholomay, R.C.; Williams, L.M.; Campbell, L.J.
1996-09-01
The US Geological Survey and the Idaho Department of Water Resources, in cooperation with the US Department of Energy, sampled 17 sites as part of a long-term project to monitor water quality of the Snake River Plain aquifer from the southern boundary of the Idaho National Engineering Laboratory to the Hagerman area. Water samples were collected and analyzed for selected radionuclides, stable isotopes, inorganic constituents, and organic compounds. The samples were collected from 11 irrigation wells, 2 domestic wells, 2 stock wells, 1 spring, and 1 public-supply well. Two quality assurance samples also were collected and analyzed. None of themore » radionuclide, inorganic constituents, or organic compound concentrations exceeded the established maximum contaminant levels for drinking water. Many of the radionuclide and inorganic constituent concentrations were greater than their respective reporting levels. All samples analyzed for dissolved organic carbon had concentrations that were greater than the minimum reporting level.« less
The analysis of benzodiazepines in forensic urine samples.
DOT National Transportation Integrated Search
1996-04-01
The FAA Toxicology and Accident Research Laboratory reports the presence of any drug detected at therapeutic or subtherapeutic levels and the medical condition for which the drug may have been used. Specimens from the pilot of a fatal aviation accide...
Taylor, Sara; Bennett, Katie M; Deignan, Joshua L; Hendrix, Ericka C; Orton, Susan M; Verma, Shalini; Schutzbank, Ted E
2014-05-01
Molecular diagnostics is a rapidly growing specialty in the clinical laboratory assessment of pathology. Educational programs in medical laboratory science and specialized programs in molecular diagnostics must address the training of clinical scientists in molecular diagnostics, but the educational curriculum for this field is not well defined. Moreover, our understanding of underlying genetic contributions to specific diseases and the technologies used in molecular diagnostics laboratories change rapidly, challenging providers of training programs in molecular diagnostics to keep their curriculum current and relevant. In this article, we provide curriculum recommendations to molecular diagnostics training providers at both the baccalaureate and master's level of education. We base our recommendations on several factors. First, we considered National Accrediting Agency for Clinical Laboratory Sciences guidelines for accreditation of molecular diagnostics programs, because educational programs in clinical laboratory science should obtain its accreditation. Second, the guidelines of several of the best known certifying agencies for clinical laboratory scientists were incorporated into our recommendations. Finally, we relied on feedback from current employers of molecular diagnostics scientists, regarding the skills and knowledge that they believe are essential for clinical scientists who will be performing molecular testing in their laboratories. We have compiled these data into recommendations for a molecular diagnostics curriculum at both the baccalaureate and master's level of education. Copyright © 2014 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
Jones, Bruce A; Bekeris, Leonas G; Nakhleh, Raouf E; Walsh, Molly K; Valenstein, Paul N
2009-01-01
Monitoring customer satisfaction is a valuable component of a laboratory quality improvement program. To survey the level of physician satisfaction with hospital clinical laboratory services. Participating institutions provided demographic and practice information and survey results of physician satisfaction with defined aspects of clinical laboratory services, rated on a scale of 1 (poor) to 5 (excellent). One hundred thirty-eight institutions participated in this study and submitted a total of 4329 physician surveys. The overall satisfaction score for all institutions ranged from 2.9 to 5.0. The median overall score for all participants was 4.1 (10th percentile, 3.6; 90th percentile, 4.5). Physicians were most satisfied with the quality/reliability of results and staff courtesy, with median values of excellent or good ratings of 89.9%. Of the 5 service categories that received the lowest percentage values of excellent/good ratings (combined scores of 4 and 5), 4 were related to turnaround time for inpatient stat, outpatient stat, routine, and esoteric tests. Surveys from half of the participating laboratories reported that 96% to 100% of physicians would recommend the laboratory to other physicians. The category most frequently selected as the most important category of laboratory services was quality/reliability of results (31.7%). There continues to be a high level of physician satisfaction and loyalty with clinical laboratory services. Test turnaround times are persistent categories of dissatisfaction and present opportunities for improvement.
Lindquester, Gary J; Burks, Romi L; Jaslow, Carolyn R
2005-01-01
Students of biology must learn the scientific method for generating information in the field. Concurrently, they should learn how information is reported and accessed. We developed a progressive set of exercises for the undergraduate introductory biology laboratory that combine these objectives. Pre- and postassessments of approximately 100 students suggest that increases occurred, some statistically significant, in the number of students using various library-related resources, in the numbers and confidence level of students using various technologies, and in the numbers and confidence levels of students involved in various activities related to the scientific method. Following this course, students should be better prepared for more advanced and independent study.
2005-01-01
Students of biology must learn the scientific method for generating information in the field. Concurrently, they should learn how information is reported and accessed. We developed a progressive set of exercises for the undergraduate introductory biology laboratory that combine these objectives. Pre- and postassessments of approximately 100 students suggest that increases occurred, some statistically significant, in the number of students using various library-related resources, in the numbers and confidence level of students using various technologies, and in the numbers and confidence levels of students involved in various activities related to the scientific method. Following this course, students should be better prepared for more advanced and independent study. PMID:15746979
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fox, K. M.; Edwards, T. B.; Mcclane, D. L.
2016-03-01
In this report, Savannah River National Laboratory provides chemical analyses and Product Consistency Test (PCT) results for a series of simulated high level waste (HLW) glasses fabricated by Pacific Northwest National Laboratory (PNNL) as part of an ongoing nepheline crystallization study. The results of these analyses will be used to improve the ability to predict crystallization of nepheline as a function of composition and heat treatment for glasses formulated at high alumina concentrations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larson, D.E.
1996-09-01
This report provides a collection of annotated bibliographies for documents prepared under the Hanford High-Level Waste Vitrification (Plant) Program. The bibliographies are for documents from Fiscal Year 1983 through Fiscal Year 1995, and include work conducted at or under the direction of the Pacific Northwest National Laboratory. The bibliographies included focus on the technology developed over the specified time period for vitrifying Hanford pretreated high-level waste. The following subject areas are included: General Documentation; Program Documentation; High-Level Waste Characterization; Glass Formulation and Characterization; Feed Preparation; Radioactive Feed Preparation and Glass Properties Testing; Full-Scale Feed Preparation Testing; Equipment Materials Testing; Meltermore » Performance Assessment and Evaluations; Liquid-Fed Ceramic Melter; Cold Crucible Melter; Stirred Melter; High-Temperature Melter; Melter Off-Gas Treatment; Vitrification Waste Treatment; Process, Product Control and Modeling; Analytical; and Canister Closure, Decontamination, and Handling« less
2013 Los Alamos National Laboratory Hazardous Waste Minimization Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salzman, Sonja L.; English, Charles J.
2015-08-24
Waste minimization and pollution prevention are inherent goals within the operating procedures of Los Alamos National Security, LLC (LANS). The US Department of Energy (DOE) and LANS are required to submit an annual hazardous waste minimization report to the New Mexico Environment Department (NMED) in accordance with the Los Alamos National Laboratory (LANL or the Laboratory) Hazardous Waste Facility Permit. The report was prepared pursuant to the requirements of Section 2.9 of the LANL Hazardous Waste Facility Permit. This report describes the hazardous waste minimization program (a component of the overall Waste Minimization/Pollution Prevention [WMin/PP] Program) administered by the Environmentalmore » Stewardship Group (ENV-ES). This report also supports the waste minimization and pollution prevention goals of the Environmental Programs Directorate (EP) organizations that are responsible for implementing remediation activities and describes its programs to incorporate waste reduction practices into remediation activities and procedures. LANS was very successful in fiscal year (FY) 2013 (October 1-September 30) in WMin/PP efforts. Staff funded four projects specifically related to reduction of waste with hazardous constituents, and LANS won four national awards for pollution prevention efforts from the National Nuclear Security Administration (NNSA). In FY13, there was no hazardous, mixedtransuranic (MTRU), or mixed low-level (MLLW) remediation waste generated at the Laboratory. More hazardous waste, MTRU waste, and MLLW was generated in FY13 than in FY12, and the majority of the increase was related to MTRU processing or lab cleanouts. These accomplishments and analysis of the waste streams are discussed in much more detail within this report.« less
Seli, Paul; Risko, Evan F; Smilek, Daniel
2016-04-01
Recent research has demonstrated that mind wandering can be subdivided into spontaneous and deliberate types, and this distinction has been found to hold at both the trait and state levels. However, to date, no attempts have been made to link trait-level spontaneous and deliberate mind wandering with state-level assessments of these two subtypes of mind wandering. Here we evaluated whether trait-level deliberate and spontaneous mind wandering map onto state levels of these subtypes of mind wandering. Results showed correspondence between trait-level reports of spontaneous and deliberate mind wandering and their state-level counterparts, indicating that people's reports on the intentionality of their mind wandering in the laboratory correspond to their reports of the intentionality of mind wandering in everyday life. Thus, the trait- and state-level scales of mind wandering were found to validate each other: Whereas the state-level measures provided some construct validity for the trait-level measures, the trait-level measures indicated that the state-level measures may be generalizable to everyday situations. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Umezawa, Taku; Brenninkmeijer, Carl A. M.; Röckmann, Thomas; van der Veen, Carina; Tyler, Stanley C.; Fujita, Ryo; Morimoto, Shinji; Aoki, Shuji; Sowers, Todd; Schmitt, Jochen; Bock, Michael; Beck, Jonas; Fischer, Hubertus; Michel, Sylvia E.; Vaughn, Bruce H.; Miller, John B.; White, James W. C.; Brailsford, Gordon; Schaefer, Hinrich; Sperlich, Peter; Brand, Willi A.; Rothe, Michael; Blunier, Thomas; Lowry, David; Fisher, Rebecca E.; Nisbet, Euan G.; Rice, Andrew L.; Bergamaschi, Peter; Veidt, Cordelia; Levin, Ingeborg
2018-03-01
We report results from a worldwide interlaboratory comparison of samples among laboratories that measure (or measured) stable carbon and hydrogen isotope ratios of atmospheric CH4 (δ13C-CH4 and δD-CH4). The offsets among the laboratories are larger than the measurement reproducibility of individual laboratories. To disentangle plausible measurement offsets, we evaluated and critically assessed a large number of intercomparison results, some of which have been documented previously in the literature. The results indicate significant offsets of δ13C-CH4 and δD-CH4 measurements among data sets reported from different laboratories; the differences among laboratories at modern atmospheric CH4 level spread over ranges of 0.5 ‰ for δ13C-CH4 and 13 ‰ for δD-CH4. The intercomparison results summarized in this study may be of help in future attempts to harmonize δ13C-CH4 and δD-CH4 data sets from different laboratories in order to jointly incorporate them into modelling studies. However, establishing a merged data set, which includes δ13C-CH4 and δD-CH4 data from multiple laboratories with desirable compatibility, is still challenging due to differences among laboratories in instrument settings, correction methods, traceability to reference materials and long-term data management. Further efforts are needed to identify causes of the interlaboratory measurement offsets and to decrease those to move towards the best use of available δ13C-CH4 and δD-CH4 data sets.
Rattray, Gordon W.; Campbell, Linford J.
2004-01-01
The U.S. Geological Survey, Idaho Department of Water Resources, and the State of Idaho INEEL Oversight Program, in cooperation with the U.S. Department of Energy, sampled water from 17 sites as part of the sixth round of a long-term project to monitor water quality of the eastern Snake River Plain aquifer from the southern boundary of the Idaho National Engineering and Environmental Laboratory to the Hagerman area. The samples were collected from eight irrigation wells, three domestic wells, one stock well, one dairy well, one commercial well, one observation well, and two springs and analyzed for selected radiochemical and chemical constituents. One quality-assurance sample, a sequential replicate, also was collected and analyzed. Many of the radionuclide and inorganic-constituent concentrations were greater than the reporting levels and most of the organic-constituent concentrations were less than the reporting levels. However, none of the reported radiochemical- or chemical-constituent concentrations exceeded the maximum contaminant levels for drinking water established by the U.S. Environmental Protection Agency. Statistical evaluation of the replicate sample pair indicated that, with 95 percent confidence, 132 of the 135 constituent concentrations of the replicate pair were equivalent.
Anthropogenic constituents in shallow ground water in the Upper Illinois River Basin
Morrow, William S.
2003-01-01
The potential for anthropogenic effects on ground water is becoming of increasing concern as land throughout the Nation becomes more urbanized. The possible contamination of water resources by volatile organic compounds (VOCs), pesticides (including transformation products), and nitrate, from current urban land use and past agricultural land use, is of particular concern. As part of the U.S. Geological Survey's National Water-Quality Assessment program, water samples for analysis of VOCs, pesticides, and nitrate were collected from 43 wells in shallow (175 feet deep or less) ground water in glacial deposits overlying a major bedrock aquifer in recently urbanized areas in the Chicago, Ill. and Milwaukee, Wis. metropolitan counties.Constituents were reported using two reporting levels. For the laboratory reporting level, the risk of a false positive or false negative detection is less than or equal to 1 percent. For the information-rich method level, estimated concentrations are identified positively and are qualified to be present on the basis of quality-control criteria, but have a higher risk of false positive detections.VOCs were detected in 32 percent (12 of 38) of the well samples with 15 detections of 7 VOCs, based on laboratory reporting levels. Concentrations ranged from 0.03 (estimated) to 4.6 micrograms per liter (?g/L), with a median concentration of 0.13 ?g/L. Methyl tert-butyl ether (MTBE) and trichloromethane (chloroform) were the most common with detections in 10 percent (4 of 38) of the well samples. Using information-rich method reporting levels, VOCs were detected in 74 percent of the wells with 37 detections of 15 VOCs. Chloroform was most common with detections in 24 percent (9 of 38) of the well samples.Pesticides were detected in 62 percent (26 of 42) of the well samples with 83 detections of 20 pesticides, based on laboratory reporting levels for the respective constituent. Concentrations ranged from 0.003 (estimated) to 3.6 (estimated) ?g/L, with a median concentration of 0.06 ?g/L. Deethylatrazine was most common with detections in 43 percent (18 of 42) of the well samples. Using information-rich method reporting levels, pesticides were detected in 74 percent (31 of 42) of the well samples with 134 detections of 29 pesticides. Deethylatrazine was most common with detections in 45 percent (19 of 42) of the well samples.Nitrate concentrations ranged from less than 0.047 to 12.5 milligrams per liter (mg/L) with a median concentration of 0.068 mg/L. Nitrate concentrations were greater than 2 mg/L in 30 percent (13 of 43) of the wells sampled. Total VOC detections did not correlate well (less than Spearman Rank correlation value of plus or minus 0.10) with well depth, age, or dissolved oxygen. Total pesticide detections did correlate with dissolved oxygen and negatively correlated with well depth. Nitrate concentrations correlated with dissolved oxygen and apparent recharge date.No VOC or pesticide concentrations exceeded U.S. Environmental Protection Agency drinking-water standards and only one nitrate 2 Anthropogenic Constituents in Shallow Ground Water in the Upper Illinois River Basin detection exceeded the standards. However, of the 43 wells sampled for VOCs or pesticides using information-rich methods, or nitrate at laboratory reporting levels, 40 of 43 (93 percent) well samples had at least one detection of a VOC or pesticide, or a detection of nitrate above 2.0 mg/L. This result indicates that most of these wells are anthropogenically affected, but presently not at U.S. Environmental Protection Agency drinking-water regulation levels of concern. The wells sampled were not public drinking-water supplies; therefore, these wells were not subject to U.S. Environmental Protection Agency drinking-water regulations.
Richards, Stephanie L; Pompei, Victoria C; Anderson, Alice
2014-01-01
New construction of biosafety level 3 (BSL-3) laboratories in the United States has increased in the past decade to facilitate research on potential bioterrorism agents. The Centers for Disease Control and Prevention inspect BSL-3 facilities and review commissioning documentation, but no single agency has oversight over all BSL-3 facilities. This article explores the extent to which standard operating procedures in US BSL-3 facilities vary between laboratories with select agent or non-select agent status. Comparisons are made for the following variables: personnel training, decontamination, personal protective equipment (PPE), medical surveillance, security access, laboratory structure and maintenance, funding, and pest management. Facilities working with select agents had more complex training programs and decontamination procedures than non-select agent facilities. Personnel working in select agent laboratories were likely to use powered air purifying respirators, while non-select agent laboratories primarily used N95 respirators. More rigorous medical surveillance was carried out in select agent workers (although not required by the select agent program) and a higher level of restrictive access to laboratories was found. Most select agent and non-select agent laboratories reported adequate structural integrity in facilities; however, differences were observed in personnel perception of funding for repairs. Pest management was carried out by select agent personnel more frequently than non-select agent personnel. Our findings support the need to promote high quality biosafety training and standard operating procedures in both select agent and non-select agent laboratories to improve occupational health and safety.
Pompei, Victoria C.; Anderson, Alice
2014-01-01
New construction of biosafety level 3 (BSL-3) laboratories in the United States has increased in the past decade to facilitate research on potential bioterrorism agents. The Centers for Disease Control and Prevention inspect BSL-3 facilities and review commissioning documentation, but no single agency has oversight over all BSL-3 facilities. This article explores the extent to which standard operating procedures in US BSL-3 facilities vary between laboratories with select agent or non–select agent status. Comparisons are made for the following variables: personnel training, decontamination, personal protective equipment (PPE), medical surveillance, security access, laboratory structure and maintenance, funding, and pest management. Facilities working with select agents had more complex training programs and decontamination procedures than non–select agent facilities. Personnel working in select agent laboratories were likely to use powered air purifying respirators, while non–select agent laboratories primarily used N95 respirators. More rigorous medical surveillance was carried out in select agent workers (although not required by the select agent program) and a higher level of restrictive access to laboratories was found. Most select agent and non–select agent laboratories reported adequate structural integrity in facilities; however, differences were observed in personnel perception of funding for repairs. Pest management was carried out by select agent personnel more frequently than non–select agent personnel. Our findings support the need to promote high quality biosafety training and standard operating procedures in both select agent and non–select agent laboratories to improve occupational health and safety. PMID:24552359
Speth, Jana; Frenzel, Clemens; Voss, Ursula
2013-09-01
We present Activity Analysis as a new method for the quantification of subjective reports of altered states of consciousness with regard to the indicated level of simulated motor activity. Empirical linguistic activity analysis was conducted with dream reports conceived immediately after EEG-controlled periods of hypnagogic hallucinations and REM-sleep in the sleep laboratory. Reports of REM-dreams exhibited a significantly higher level of simulated physical dreamer activity, while hypnagogic hallucinations appear to be experienced mostly from the point of passive observer. This study lays the groundwork for clinical research on the level of simulated activity in pathologically altered states of subjective experience, for example in the REM-dreams of clinically depressed patients, or in intrusions and dreams of patients diagnosed with PTSD. Copyright © 2013 Elsevier Inc. All rights reserved.
1992-12-01
1992 6-~1 SOME RESULTS IN MACIIINE- LEARNING Mike Breen Assistant Professor Department of Mathematics Tennessee Technological Universitv Abstract The...Research Laboratory; Wilford Hall Medical Center 12 High School Apprenticeship Program Reports: Armstrong Laboratory 13 High School Apprenticeship ...Program Reports: Phillips Laboratory 14 High School Apprenticeship Program Reports: Rome Laboratory 15 High School Apprenticeship Program Reports
Krambeck, Amy E; Khan, Naseem F; Jackson, Molly E; Lingeman, James E; McAteer, James A; Williams, James C
2010-10-01
We determined the accuracy of stone composition analysis at commercial laboratories. A total of 25 human renal stones with infrared spectroscopy determined composition were fragmented into aliquots and studied with micro computerized tomography to ensure fragment similarity. Representative fragments of each stone were submitted to 5 commercial stone laboratories for blinded analysis. All laboratories agreed on the composition of 6 pure stones. Only 2 of 4 stones (50%) known to contain struvite were identified as struvite at all laboratories. Struvite was reported as a component by some laboratories for 4 stones previously determined not to contain struvite. Overall there was disagreement regarding struvite in 6 stones (24%). For 9 calcium oxalate stones all laboratories reported some mixture of calcium oxalate but the quantity of subtypes differed significantly among laboratories. In 6 apatite containing stones apatite was missed by the laboratories in 20% of samples. None of the laboratories identified atazanavir in a stone containing that antiviral drug. One laboratory reported protein in every sample while all others reported it in only 1. Nomenclature for apatite differed among laboratories with 1 reporting apatite as carbonate apatite and never hydroxyapatite, another never reporting carbonate apatite and always reporting hydroxyapatite, and a third reporting carbonate apatite as apatite with calcium carbonate. Commercial laboratories reliably recognize pure calculi. However, variability in the reporting of mixed calculi suggests a problem with the accuracy of stone analysis results. There is also a lack of standard nomenclature used by laboratories. Copyright © 2010 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Krambeck, Amy E.; Khan, Naseem F.; Jackson, Molly E.; Lingeman, James E.; McAteer, James A; Williams, James C.
2011-01-01
INTRODUCTION The goal of this study was to determine the accuracy of stone composition analysis by commercial laboratories. METHODS 25 human renal stones with infrared spectroscopy (IR) determined compositions were fragmented into aliquots and studied with micro-computed tomography (CT) to ensure fragment similarity. Representative fragments of each stone were submitted to 5 commercial stone laboratories for blinded analysis. RESULTS All laboratories agreed on composition for 6 pure stones. Of 4 stones known to contain struvite, only 2(50%) were identified as struvite by all laboratories. Struvite was reported as a component by some laboratories for 4 stones previously determined not to contain struvite. Overall, there was disagreement regarding struvite in 6(24%) stones. For 9 calcium oxalate (CaOx) stones, all laboratories reported some mixture of CaOx, but the quantities of subtypes differed significantly among laboratories. In 6 apatite containing stones, apatite was missed by the laboratories in 20% of the samples. None of the laboratories identified atazanavir in a stone containing that antiviral drug. One laboratory reported protein in every sample, while all others reported it in only 1 sample. Nomenclature for apatite differed among laboratories, with one reporting apatite as carbonate apatite (CA) and never hydroxyapatite (HA), another never reporting CA and always reporting HA, and a third reporting CA as apatite with calcium carbonate. CONCLUSIONS Commercial laboratories reliably recognize pure calculi; however, variability in reporting of mixed calculi suggests a problem with accuracy of stone analysis results. Furthermore, there is a lack of standard nomenclature used by laboratories. PMID:20728108
DOE Office of Scientific and Technical Information (OSTI.GOV)
V. Finley
This report provides the U.S. Department of Energy (DOE) and the public with information on the level of radioactive and non-radioactive pollutants (if any) that are added to the environment as a result of Princeton Plasma Physics Laboratory's (PPPL) operations. The results of the 2004 environmental surveillance and monitoring program for PPPL's are presented and discussed. The report also summarizes environmental initiatives, assessments, and programs that were undertaken in 2004.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gallegos, Gretchen M.; Terusaki, Stan H.
2013-12-01
An ecological risk assessment is required as part of the Resource Recovery and Conservation Act (RCRA) permit renewal process for Miscellaneous Units subject to 22 CCR 66270.23. This risk assessment is prepared in support of the RCRA permit renewal for the Explosives Waste Treatment Facility (EWTF) at Site 300 of the Lawrence Livermore National Laboratory (LLNL). LLNL collected soil samples and used the resulting data to produce a scoping-level ecological risk assessment pursuant to the Department of Toxic Substances Control, Guidance for Ecological Risk Assessment at Hazardous Waste Sites and Permitted Facilities, Part A: Overview, July 4, 1996. The scoping-levelmore » ecological risk assessment provides a framework to determine the potential interaction between ecological receptors and chemicals of concern from hazardous waste treatment operations in the area of EWTF. A scoping-level ecological risk assessment includes the step of conducting soil sampling in the area of the treatment units. The Sampling Plan in Support of the Human Health and Ecological Risk Assessment for the Operation of the Explosives Waste Treatment Facility at Site 300 of the Lawrence Livermore National Laboratory, (Terusaki, 2007), outlines the EWTF project-specific soil sampling requirements. Soil samples were obtained and analyzed for constituents from four chemical groups: furans, explosives, semi-volatiles and metals. Analytical results showed that furans, explosives and semi-volatiles were not detected; therefore, no further analysis was conducted. The soil samples did show the presence of metals. Soil samples analyzed for metals were compared to site-wide background levels, which had been developed for site -wide cleanup activities pursuant to the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). Total metal concentrations from 28 discrete soil samples obtained in the EWTF area were all below CERCLA-developed background levels. Therefore, following DTSC 1996 guidance, the EWTF hazardous waste treatment units exit the ecological risk evaluation process upon completion of the requirements of a scoping-level assessment report. This summary report documents that the requirements of a scoping-level assessment have been met.« less
Critical Value Reporting at Egyptian Laboratories.
Mosallam, Rasha; Ibrahim, Samaa Zenhom
2015-06-12
To examine critical value reporting policies and practices and to identify critical value ranges for selected common laboratory assays at inpatient division of laboratories of Alexandria hospitals. A cross-sectional descriptive study design was used. Subjects were from inpatient division of all laboratories of Alexandria hospitals (40 laboratories). Data were collected using a questionnaire composed of 4 sections. The first section explored hospital and laboratory characteristics. The second section assessed policies and procedures of critical value reporting. The third section explored the reporting process. The fourth section explored critical value ranges for selected common laboratory assays. Written procedure for reporting of critical values was present in 77.5% of laboratories and a comprehensive list of critical values in 72.55%. For laboratories having a critical value list, the number of tests in the list ranged from 7 to 40. Three-fifths of laboratories had a policy for assessing the timeliness of reporting and 3 quarters stated that the laboratory policy requires feedback (60.0% and 75.0%, respectively). The hospital laboratory physician was responsible for critical value reporting followed by the laboratory technician (75.0% and 50.0%, respectively). The call is received mainly by nurses and physicians ordering the test (67.5% and 55.0%, respectively) and the channel of reporting is mainly the telephone or through sending test report to the ward (67.5% and 50.0%, respectively). Wireless technologies are used in reporting in only 10.0% of hospitals. The cutoff limits for reporting different assays showed considerable interlaboratory variation. Critical value policies and practices showed interinstitutional variation with deficiencies in some reporting practices. Selection of critical assays for notification and setting the limits of notification exhibited wide variation as well.
McDonald, Jeffrey G.; Cummins, Carolyn L.; Barkley, Robert M.; Thompson, Bonne M.; Lincoln, Holly A.
2009-01-01
Reported here is the mass spectral identification of sorbitol-based nuclear clarifying agents (NCAs) and the quantitative description of their extractability from common laboratory and household plasticware made of polypropylene. NCAs are frequently added to polypropylene to improve optical clarity, increase performance properties, and aid in the manufacturing process of this plastic. NCA addition makes polypropylene plasticware more aesthetically pleasing to the user and makes the product competitive with other plastic formulations. We show here that several NCAs are readily extracted with either ethanol or water from plastic labware during typical laboratory procedures. Observed levels ranged from a nanogram to micrograms of NCA. NCAs were also detected in extracts from plastic food storage containers; levels ranged from 1to 10 μg in two of the three brands tested. The electron ionization mass spectra for three sorbitol-based nuclear clarifying agents (1,3:2,4-bis-O-(benzylidene)sorbitol, 1,3:2,4-bis-O-(p-methylbenzylidene)sorbitol, 1,3:2,4-bis-O-(3,4-dimethylbenzylidene)sorbitol) are presented for the native and trimethylsilylderivatized compounds together with the collision-induced dissociation mass spectra; gas and liquid chromatographic data are also reported. These NCAs now join other well-known plasticizers such as phthalate esters and bisphenol A as common laboratory contaminants. While the potential toxicity of NCAs in mammalian systems is unknown, the current data provide scientists and consumers the opportunity to make more informed decisions regarding the use of polypropylene plastics. PMID:18533681
Kaufman, Harvey W; Williams, Fred R; Odeh, Mouneer A
2011-01-01
Employer-sponsored health risk assessments (HRA) may include laboratory tests to provide evidence of disease and disease risks for common medical conditions. We evaluated the ability of HRA-laboratory testing to provide new disease-risk information to participants. We performed a cross-sectional analysis of HRA-laboratory results for participating adult employees and their eligible spouses or their domestic partners, focusing on three common health conditions: hyperlipidemia, diabetes mellitus, and chronic kidney disease. HRA with laboratory results of 52,270 first-time participants were analyzed. Nearly all participants had access to health insurance coverage. Twenty-four percent (12,392) self-reported one or more of these medical conditions: 21.1% (11,017) self-identified as having hyperlipidemia, 4.7% (2,479) self-identified as having diabetes, and 0.7% (352) self-identified as having chronic kidney disease. Overall, 36% (n = 18,540) of participants had laboratory evidence of at least one medical condition newly identified: 30.7% (16,032) had laboratory evidence of hyperlipidemia identified, 1.9% (984) had laboratory evidence of diabetes identified, and 5.5% (2,866) had laboratory evidence of chronic kidney disease identified. Of all participants with evidence of hyperlipidemia 59% (16,030 of 27,047), were newly identified through the HRA. Among those with evidence of diabetes 28% (984 of 3,463) were newly identified. The highest rate of newly identified disease risk was for chronic kidney disease: 89% (2,866 of 3,218) of participants with evidence of this condition had not self-reported it. Men (39%) were more likely than women (33%) to have at least one newly identified condition (p<0.0001). Among men, lower levels of educational achievement were associated with modestly higher rates of newly identified disease risk (p<0.0001); the association with educational achievement among women was unclear. Even among the youngest age range (20 to 29 year olds), nearly 1 in 4 participants (24%) had a newly identified risk for disease. These results support the important role of employer-sponsored laboratory testing as an integral element of HRA for identifying evidence of previously undiagnosed common medical conditions in individuals of all working age ranges, regardless of educational level and gender.
Jacob, Peyton; Holiday, David B.; Benowitz, Neal L.; Sosnoff, Connie S.; Doig, Mira V.; Feyerabend, Colin; Aldous, Kenneth M.; Sharifi, Mehran; Kellogg, Mark D.; Langman, Loralie J.
2009-01-01
Introduction: Cotinine, the primary proximate metabolite of nicotine, is commonly measured as an index of exposure to tobacco in both active users of tobacco and nonsmokers with possible exposure to secondhand smoke (SHS). A number of laboratories have implemented analyses for measuring serum cotinine in recent years, but there have been few interlaboratory comparisons of the results. Among nonsmokers exposed to SHS, the concentration of cotinine in blood can be quite low, and extensive variability in these measurements has been reported in the past. Methods: In this study, a group of seven laboratories, all experienced in serum cotinine analysis, measured eight coded serum pools with concentrations ranging from background levels of about 0.05 ng/ml to relatively high concentrations in the active smokers range. All laboratories used either gas–liquid chromatography with nitrogen–phosphorus detection or liquid chromatography with mass spectrometric detection. Results: All seven laboratories reliably measured the cotinine concentrations in samples that were within the range of their methods. In each case, the results for the pools were correctly ranked in order, and no significant interlaboratory bias was observed at the 5% level of significance for results from any of the pools. Discussion: We conclude that present methods of chromatographic analysis of serum cotinine, as used by these experienced laboratories, are capable of providing accurate and precise results in both the smoker and the nonsmoker concentration range. PMID:19933777
Ravichandran, Ramamoorthy; Binukumar, Johnson Pichy; Davis, Cheriyathmanjiyil Antony
2013-01-01
The measured dose in water at reference point in phantom is a primary parameter for planning the treatment monitor units (MU); both in conventional and intensity modulated/image guided treatments. Traceability of dose accuracy therefore still depends mainly on the calibration factor of the ion chamber/dosimeter provided by the accredited Secondary Standard Dosimetry Laboratories (SSDLs), under International Atomic Energy Agency (IAEA) network of laboratories. The data related to Nd,water calibrations, thermoluminescent dosimetry (TLD) postal dose validation, inter-comparison of different dosimeter/electrometers, and validity of Nd,water calibrations obtained from different calibration laboratories were analyzed to find out the extent of accuracy achievable. Nd,w factors in Gray/Coulomb calibrated at IBA, GmBH, Germany showed a mean variation of about 0.2% increase per year in three Farmer chambers, in three subsequent calibrations. Another ion chamber calibrated in different accredited laboratory (PTW, Germany) showed consistent Nd,w for 9 years period. The Strontium-90 beta check source response indicated long-term stability of the ion chambers within 1% for three chambers. Results of IAEA postal TL “dose intercomparison” for three photon beams, 6 MV (two) and 15 MV (one), agreed well within our reported doses, with mean deviation of 0.03% (SD 0.87%) (n = 9). All the chamber/electrometer calibrated by a single SSDL realized absorbed doses in water within 0.13% standard deviations. However, about 1-2% differences in absorbed dose estimates observed when dosimeters calibrated from different calibration laboratories are compared in solid phantoms. Our data therefore imply that the dosimetry level maintained for clinical use of linear accelerator photon beams are within recommended levels of accuracy, and uncertainties are within reported values. PMID:24672156
NASA Astrophysics Data System (ADS)
Vadapally, Praveen
This study sought to understand the impact of gender and reasoning level on students' perceptions and performances of Predict-Observe-Explain (POE) laboratory tasks in a high school chemistry laboratory. Several literature reviews have reported that students at all levels have not developed the specific knowledge and skills that were expected from their laboratory work. Studies conducted over the last several decades have found that boys tend to be more successful than girls in science and mathematics courses. However, some recent studies have suggested that girls may be reducing this gender gap. This gender difference is the focal point of this research study, which was conducted at a mid-western, rural high school. The participants were 24 boys and 25 girls enrolled in two physical science classes taught by the same teacher. In this mixed methods study, qualitative and quantitative methods were implemented simultaneously over the entire period of the study. MANOVA statistics revealed significant effects due to gender and level of reasoning on the outcome variables, which were POE performances and perceptions of the chemistry laboratory environment. There were no significant interactions between these effects. For the qualitative method, IRB-approved information was collected, coded, grouped, and analyzed. This method was used to derive themes from students' responses on questionnaires and semi-structured interviews. Students with different levels of reasoning and gender were interviewed, and many of them expressed positive themes, which was a clear indication that they had enjoyed participating in the POE learning tasks and they had developed positive perceptions towards POE inquiry laboratory learning environment. When students are capable of formal reasoning, they can use an abstract scientific concept effectively and then relate it to the ideas they generate in their minds. Thus, instructors should factor the nature of students' thinking abilities into their instructional strategies and strive to create a learning environment where students are engaged in thinking, learning, and acting in meaningful and beneficial ways. POE learning tasks enhance students' laboratory experiences and can help deepen their understanding of the empirical nature of science. Key words: predict observe explain, gender, science laboratory inquiry, reasoning ability, social constructivism, mixed methods.
Stacey, Peter; Butler, Owen
2008-06-01
This paper emphasizes the need for occupational hygiene professionals to require evidence of the quality of welding fume data from analytical laboratories. The measurement of metals in welding fume using atomic spectrometric techniques is a complex analysis often requiring specialist digestion procedures. The results from a trial programme testing the proficiency of laboratories in the Workplace Analysis Scheme for Proficiency (WASP) to measure potentially harmful metals in several different types of welding fume showed that most laboratories underestimated the mass of analyte on the filters. The average recovery was 70-80% of the target value and >20% of reported recoveries for some of the more difficult welding fume matrices were <50%. This level of under-reporting has significant implications for any health or hygiene studies of the exposure of welders to toxic metals for the types of fumes included in this study. Good laboratories' performance measuring spiked WASP filter samples containing soluble metal salts did not guarantee good performance when measuring the more complex welding fume trial filter samples. Consistent rather than erratic error predominated, suggesting that the main analytical factor contributing to the differences between the target values and results was the effectiveness of the sample preparation procedures used by participating laboratories. It is concluded that, with practice and regular participation in WASP, performance can improve over time.
NASA Astrophysics Data System (ADS)
Onuoha, Cajetan O.
The purpose of this research study was to determine the overall effectiveness of computer-based laboratory compared with the traditional hands-on laboratory for improving students' science academic achievement and attitudes towards science subjects at the college and pre-college levels of education in the United States. Meta-analysis was used to synthesis the findings from 38 primary research studies conducted and/or reported in the United States between 1996 and 2006 that compared the effectiveness of computer-based laboratory with the traditional hands-on laboratory on measures related to science academic achievements and attitudes towards science subjects. The 38 primary research studies, with total subjects of 3,824 generated a total of 67 weighted individual effect sizes that were used in this meta-analysis. The study found that computer-based laboratory had small positive effect sizes over the traditional hands-on laboratory (ES = +0.26) on measures related to students' science academic achievements and attitudes towards science subjects (ES = +0.22). It was also found that computer-based laboratory produced more significant effects on physical science subjects compared to biological sciences (ES = +0.34, +0.17).
Lyon, Elaine; Schrijver, Iris; Weck, Karen E; Ferreira-Gonzalez, Andrea; Richards, C Sue; Palomaki, Glenn E
2015-03-01
Molecular testing for cystic fibrosis mutations is widespread and routine in reproductive decision making and diagnosis. Our objective was to assess the level of performance of laboratories for this test. The College of American Pathologists administers external proficiency testing with multiple DNA samples distributed biannually. RESULTS are analyzed, reviewed, and graded by the joint College of American Pathologists/American College of Medical Genetics and Genomics Biochemical and Molecular Genetics Committee. Assessment is based on genotype and associated clinical interpretation. Overall, 357 clinical laboratories participated in the proficiency testing survey between 2003 and 2013 (322 in the United States and 35 international). In 2013, US participants reported performing nearly 120,000 tests monthly. Analytical sensitivity and specificity of US laboratories were 98.8% (95% confidence interval: 98.4-99.1%) and 99.6% (95% confidence interval: 99.4-99.7%), respectively. Analytical sensitivity improved between 2003 and 2008 (from 97.9 to 99.3%; P = 0.007) and remained steady thereafter. Clinical interpretation matched the intended response for 98.8, 86.0, and 91.0% of challenges with no, one, or two mutations, respectively. International laboratories performed similarly. Laboratory testing for cystic fibrosis in the United States has improved since 2003, and these data demonstrate a high level of quality. Neither the number of samples tested nor test methodology affected performance.
DiBartolomeis, Susan M
2011-01-01
Several reports on science education suggest that students at all levels learn better if they are immersed in a project that is long term, yielding results that require analysis and interpretation. I describe a 12-wk laboratory project suitable for upper-level undergraduates and first-year graduate students, in which the students molecularly locate and map a gene from Drosophila melanogaster called dusky and one of dusky's mutant alleles. The mapping strategy uses restriction fragment length polymorphism analysis; hence, students perform most of the basic techniques of molecular biology (DNA isolation, restriction enzyme digestion and mapping, plasmid vector subcloning, agarose and polyacrylamide gel electrophoresis, DNA labeling, and Southern hybridization) toward the single goal of characterizing dusky and the mutant allele dusky(73). Students work as individuals, pairs, or in groups of up to four students. Some exercises require multitasking and collaboration between groups. Finally, results from everyone in the class are required for the final analysis. Results of pre- and postquizzes and surveys indicate that student knowledge of appropriate topics and skills increased significantly, students felt more confident in the laboratory, and students found the laboratory project interesting and challenging. Former students report that the lab was useful in their careers.
DiBartolomeis, Susan M.
2011-01-01
Several reports on science education suggest that students at all levels learn better if they are immersed in a project that is long term, yielding results that require analysis and interpretation. I describe a 12-wk laboratory project suitable for upper-level undergraduates and first-year graduate students, in which the students molecularly locate and map a gene from Drosophila melanogaster called dusky and one of dusky's mutant alleles. The mapping strategy uses restriction fragment length polymorphism analysis; hence, students perform most of the basic techniques of molecular biology (DNA isolation, restriction enzyme digestion and mapping, plasmid vector subcloning, agarose and polyacrylamide gel electrophoresis, DNA labeling, and Southern hybridization) toward the single goal of characterizing dusky and the mutant allele dusky73. Students work as individuals, pairs, or in groups of up to four students. Some exercises require multitasking and collaboration between groups. Finally, results from everyone in the class are required for the final analysis. Results of pre- and postquizzes and surveys indicate that student knowledge of appropriate topics and skills increased significantly, students felt more confident in the laboratory, and students found the laboratory project interesting and challenging. Former students report that the lab was useful in their careers. PMID:21364104
A global quantification of “normal” sleep schedules using smartphone data
Walch, Olivia J.; Cochran, Amy; Forger, Daniel B.
2016-01-01
The influence of the circadian clock on sleep scheduling has been studied extensively in the laboratory; however, the effects of society on sleep remain largely unquantified. We show how a smartphone app that we have developed, ENTRAIN, accurately collects data on sleep habits around the world. Through mathematical modeling and statistics, we find that social pressures weaken and/or conceal biological drives in the evening, leading individuals to delay their bedtime and shorten their sleep. A country’s average bedtime, but not average wake time, predicts sleep duration. We further show that mathematical models based on controlled laboratory experiments predict qualitative trends in sunrise, sunset, and light level; however, these effects are attenuated in the real world around bedtime. Additionally, we find that women schedule more sleep than men and that users reporting that they are typically exposed to outdoor light go to sleep earlier and sleep more than those reporting indoor light. Finally, we find that age is the primary determinant of sleep timing, and that age plays an important role in the variability of population-level sleep habits. This work better defines and personalizes “normal” sleep, produces hypotheses for future testing in the laboratory, and suggests important ways to counteract the global sleep crisis. PMID:27386531
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rigo, H.G.; Chandler, A.J.
Volume II (part 2 of 2) of ''Retrofit of Waste-to-energy Facilities Equipped with Electrostatic Precipitators'' contains the field and laboratory reports, including: (1) field reports, (2) analytic laboratory reports, (3) chain of custody forms, and (4) TCLP laboratory reports.
Annual Site Environmental Report Calendar Year 2010
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kayser, Dan
This report summarizes the environmental status of Ames Laboratory for calendar year 2010. It includes descriptions of the Laboratory site, its mission, the status of its compliance with applicable environmental regulations, its planning and activities to maintain compliance, and a comprehensive review of its environmental protection, surveillance and monitoring activities. In 2010, the Laboratory accumulated and disposed of waste under U.S. Environmental Protection Agency (EPA) issued generator numbers. All waste is handled according to all applicable EPA, State, Local regulations and DOE Orders. In 2006 the Laboratory reduced its generator status from a Large Quantity Generator (LQG) to a Smallmore » Quantity Generator (SQG). EPA Region VII was notified of this change. The Laboratory's RCRA hazardous waste management program was inspected by EPA Region VII in April 2006. There were no notices of violations. The inspector was impressed with the improvements of the Laboratory's waste management program over the past ten years. The Laboratory was in compliance with all applicable federal, state, local and DOE regulations and orders in 2010. There were no radiological air emissions or exposures to the general public due to Laboratory activities in 2010. See U.S. Department of Energy Air Emissions Annual Report in Appendix B. As indicated in prior SERs, pollution awareness, waste minimization and recycling programs have been in practice since 1990, with improvements implemented most recently in 2010. Included in these efforts were battery and CRT recycling, miscellaneous electronic office equipment, waste white paper and green computer paper-recycling and corrugated cardboard recycling. Ames Laboratory also recycles/reuses salvageable metal, used oil, foamed polystyrene peanuts, batteries, fluorescent lamps and telephone books. Ames Laboratory reported to DOE-Ames Site Office (AMSO), through the Laboratory's Performance Evaluation Measurement Plan, on its Affirmative Procurement Performance Measure. A performance level of 'A-' was achieved in 2010 for Integrated Safety, Health and Environmental Protection. As reported in Site Environmental Reports for prior years, the Laboratory's Environmental Management System (EMS) has been integrated into the Laboratory's Integrated Safety Management System since 2005. The integration of EMS into the way the Laboratory does business allows the Laboratory to systematically review, address and respond to the Laboratory's environmental impacts. The Laboratory's EMS was audited in April 2009 by DOE-CH. There were four 'Sufficiently in Conformity' findings as a result of the audit. All four findings were tracked in the Laboratory's corrective action database for completion. Beryllium was used routinely at Ames Laboratory in the 1940's and 1950's in processes developed for the production of highly pure uranium and thorium in support of the historic Manhattan Project. Laboratory metallurgists also worked on a process to produce pure beryllium metal from beryllium fluoride. In the early 1950's, beryllium oxide powder was used to produce shaped beryllium and crucibles. As a result of that work, beryllium contamination now exists in many interstitial spaces (e.g., utility chases) and ventilation systems in Wilhelm, Spedding and Metals Development buildings. Extensive characterization and remediation efforts have occurred in 2009 and 2010 in order to better understand the extent of the contamination. Analysis of extensive sampling data suggests that a fairly wide dispersion of beryllium occurred (most likely in the 1950's and 60's) in Wilhelm Hall and in certain areas of Spedding Hall and Metals Development. Area air-sampling results and work-area surface characterizations indicate the exposure potential to current workers, building visitors and the public remains extremely low. This information is now used to guide cleaning efforts and to provide worker protection during remodeling and maintenance activities. Results were shared with the DOE's Former Worker Program to support former worker medical testing and compensation programs. A complete discussion of the Laboratory's beryllium characterization and remediation efforts can be found at: http://www.ameslab.gov/operations/esha/beryllium-information.« less
Luppens, James A.; Janke, Louis G.; McCord, Jamey D.; Bullock, John H.; Brazeau, Lisa; Affronter, Ronald H.
2007-01-01
A performance audit of the U.S. Geological Survey (USGS), Energy Resource Program (ERP) Inorganic Geochemistry Laboratory (IGL) was conducted between August, 2003 and October, 2005. The goals were to ensure that a high level of analytical performance was maintained and identify any areas that could be enhanced. The audit was subdivided into three phases. Phase 1 was a preliminary assessment of current performance based on recent performance on CANSPEX samples. IGL performance was also compared to laboratories world-wide with similar scope. Phase 2 consisted of the implementation of the recommended changes made in Phase 1. Phase 3 of the audit consisted of a reassessment effort to evaluate the effectiveness of the recommendations made in the Phase 1 and an on-site audit of the laboratory facilities. Phases 1 and 3 required summary reports that are included in Appendices A and B of this report. The audit found that the IGL was one of the top two laboratories compared for trace element analyses. Several recommendations to enhance performance on major and minor elemental parameters were made and implemented. Demonstrated performance improvements as a result of the recommended changes were documented. Several initiatives to sustain the performance improvements gained from the audit have been implemented.
Turiac, I A; Fortunato, F; Cappelli, M G; Morea, A; Chironna, M; Prato, Rosa; Martinelli, D
2018-04-01
This study aimed at evaluating the integrated measles and rubella surveillance system (IMRSS) in Apulia region, Italy, from its introduction in 2013 to 30 June 2016. Measles and rubella case reports were extracted from IMRSS. We estimated system sensitivity at the level of case reporting, using the capture-recapture method for three data sources. Data quality was described as the completeness of variables and timeliness of notification as the median-time interval from symptoms onset to initial alert. The proportion of suspected cases with laboratory investigation, the rate of discarded cases and the origin of infection were also computed. A total of 127 measles and four rubella suspected cases were reported to IMRSS and 82 were laboratory confirmed. Focusing our analysis on measles, IMRSS sensitivity was 82% (95% CI: 75-87). Completeness was >98% for mandatory variables and 57% for 'genotyping'. The median-time interval from symptoms onset to initial alert was 4.5 days, with a timeliness of notification of 33% (41 cases reported ⩽48 h). The proportion of laboratory investigation was 87%. The rate of discarded cases was 0.1 per 100 000 inhabitants per year. The origin of infection was identified for 85% of cases. It is concluded that IMRSS provides good quality data and has good sensitivity; still efforts should be made to improve the completeness of laboratory-related variables, timeliness and to increase the rate of discarded cases.
Decontamination and decommissioning of the BORAX-V leach pond. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, D.L.
1985-01-01
This report describes the decontamination and decommissioning (D and D) of the BORAX-V leach pond located at the Idaho National Engineering Laboratory (INEL). The leach pond became radioactively contaminated from the periodic discharge of low-level liquid waste during operation of the Boiling Water Reactor Experiments (BORAX) from 1954 to 1964. This report describes work performed to accomplish the D and D objectives of stabilizing the leach pond and preventing the spread of contamination. D and D of the BORAX-V leach pond consisted to backfilling the pond with clean soil, grading and seeding the area, and erecting a permanent marker tomore » identify very low-level subsurface contamination.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arntzen, Evan V.; Hand, Kristine D.; Carter, Kathleen M.
At the request of the U.S. Army Corps of Engineers (USACE; Portland District), Pacific Northwest National Laboratory (PNNL) undertook a project in 2006 to look further into issues of total dissolved gas (TDG) supersaturation in the lower Columbia River downstream of Bonneville Dam. In FY 2008, the third year of the project, PNNL conducted field monitoring and laboratory toxicity testing to both verify results from 2007 and answer some additional questions about how salmonid sac fry respond to elevated TDG in the field and the laboratory. For FY 2008, three objectives were 1) to repeat the 2006-2007 field effort tomore » collect empirical data on TDG from the Ives Island and Multnomah Falls study sites; 2) to repeat the static laboratory toxicity tests on hatchery chum salmon fry to verify 2007 results and to expose wild chum salmon fry to incremental increases in TDG, above those of the static test, until external symptoms of gas bubble disease were clearly present; and 3) to assess physiological responses to TDG levels in wild chum salmon sac fry incubating below Bonneville Dam during spill operations. This report summarizes the tasks conducted and results obtained in pursuit of the three objectives. Chapter 1 discusses the field monitoring, Chapter 2 reports the findings of the laboratory toxicity tests, and Chapter 3 describes the field-sampling task. Each chapter contains an objective-specific introduction, description of the study site and methods, results of research, and discussion of findings. Literature cited throughout this report is listed in Chapter 4. Additional details on the monitoring methodology and results are provided in Appendices A and B included on the compact disc bound inside the back cover of the printed version of this report.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Finley, V.L.; Stencel, J.R.
This report gives the results of the environmental activities and monitoring programs at the Princeton Plasma Physics Laboratory (PPPL) for CY91. The report is prepared to provide the US Department of Energy (DOE) and the public with information on the level of radioactive and nonradioactive pollutants, if any, added to the environment as a result of PPPL operations, as well as environmental initiatives, assessments, and programs. The objective of the Annual Site Environmental Report is to document evidence that DOE facility environmental protection programs adequately protect the environment and the public health.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Finley, V.L.; Wieczorek, M.A.
This report gives the results of the environmental activities and monitoring programs at the Princeton Plasma Physics Laboratory (PPPL) for CY92. The report is prepared to provide the US Department of Energy (DOE) and the public with information on the level of radioactive and nonradioactive pollutants, if any, added to the environment as a result of PPPL operations, as well as environmental initiatives, assessments, and programs. The objective of the Annual Site Environmental Report is to document evidence that DOE facility environmental protection programs adequately protect the environment and the public health.
Environmental surveillance at Los Alamos during 1987
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1988-05-01
This report describes the environmental surveillance program conducted by Los Alamos National Laboratory during 1987. Routine monitoring for radiation and radioactive or chemical materials is conducted on the Laboratory site as well as in the surrounding region. Monitoring results are used to determine compliance with appropriate standards and to permit early identification of potentially undesirable trends. Results and interpretation of data for 1987 cover: external penetrating radiation; quantities of airborne emissions and liquid effluents; concentrations of chemicals and radionuclides in ambient air, surface and ground waters, municipal water supply, soils and sediments, and foodstuffs; and environmental compliance. Comparisons with appropriatemore » standards, regulations, and background levels provide the basis for concluding that environmental effects from Laboratory operations are insignificant and do not pose a threat to the public, Laboratory employees, or the environment. 113 refs., 33 figs., 120 tabs.« less
Environmental surveillance at Los Alamos during 1991. Environmental protection group
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dewart, J.; Kohen, K.L.
1993-08-01
This report describes the environmental surveillance program conducted by Los Alamos National Laboratory during 1991. Routine monitoring for radiation and for radioactive and chemical materials is conducted on the Laboratory site as well as in the surrounding region. Monitoring results are used to determine compliance with appropriate standards and to permit early identification of potentially undesirable trends. Results and interpretation of data for 1991 cover external penetrating radiation; quantities of airborne emissions and effluents; concentrations of chemicals and radionuclides in ambient air, surface waters and groundwaters, municipal water supply, soils and sediments, and foodstuffs; and environmental compliance. Comparisons with appropriatemore » standards, regulations, and background levels provide the basis for concluding that environmental effects from Laboratory operations are small and do not pose a threat to the public, Laboratory employees, or the environment.« less
Discovery & Interaction in Astro 101 Laboratory Experiments
NASA Astrophysics Data System (ADS)
Maloney, Frank Patrick; Maurone, Philip; DeWarf, Laurence E.
2016-01-01
The availability of low-cost, high-performance computing hardware and software has transformed the manner by which astronomical concepts can be re-discovered and explored in a laboratory that accompanies an astronomy course for arts students. We report on a strategy, begun in 1992, for allowing each student to understand fundamental scientific principles by interactively confronting astronomical and physical phenomena, through direct observation and by computer simulation. These experiments have evolved as :a) the quality and speed of the hardware has greatly increasedb) the corresponding hardware costs have decreasedc) the students have become computer and Internet literated) the importance of computationally and scientifically literate arts graduates in the workplace has increased.We present the current suite of laboratory experiments, and describe the nature, procedures, and goals in this two-semester laboratory for liberal arts majors at the Astro 101 university level.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Virginia L. Finley, Editor
This report provides the U.S. Department of Energy (DOE) and the public with information on the level of radioactive and non-radioactive pollutants (if any) that are added to the environment as a result of Princeton Plasma Physics Laboratory's (PPPL) operations. The results of the 2002 and 2003 environmental surveillance and monitoring program for PPPL are presented and discussed. The report also summarizes environmental initiatives, assessments, and programs that were undertaken in 2002 and 2003.
Kahn, Rachel E; Frick, Paul J; Golmaryami, Farrah N; Marsee, Monica A
2017-04-01
In a sample of detained male adolescents (n = 107; Mean age = 15.50; SD = 1.30), we tested whether anxiety moderated the association of CU traits with self-report and computerized measures of affective (emotional reactivity) and cognitive (affective facial recognition and Theory of Mind [ToM]) empathy. Hierarchical regression analyses revealed that CU traits were negatively associated with self-reports of affective empathy and this association was not moderated by level of anxiety. Significant interactions revealed that CU traits were negatively associated with cognitive empathy (self-report) only at high levels of anxiety, whereas CU traits were positively associated with cognitive empathy on the ToM task only at low levels of anxiety. CU traits were also associated with greater fear recognition accuracy at low levels of anxiety. Implications for understanding and treating different variants of CU traits (i.e., primary and secondary) are discussed.
1978-06-01
stimulate at-least three levels of crew function. At the most complex level, visual cues are used to discriminate the presence or activities of...limited to motion on- set cues washed out at subliminal levels.. Because of the cues they provide the driver, gunner, and commander, and the dis...motion, i.e.,which physiological receptors are affected, how they function,and how they may be stimulated by a simulator motion system. I Motion is
ERIC Educational Resources Information Center
DiBartolomeis, Susan M.
2011-01-01
Several reports on science education suggest that students at all levels learn better if they are immersed in a project that is long term, yielding results that require analysis and interpretation. I describe a 12-wk laboratory project suitable for upper-level undergraduates and first-year graduate students, in which the students molecularly…
2017-09-05
AFRL-RX-WP-JA-2017-0321 ATOMIC LEVEL CLEANING OF POLY-METHYL- METHACRYLATE RESIDUES FROM THE GRAPHENE SURFACE USING RADIOLIZED WATER AT...N. Zakharov and Eric A. Stach Brookhaven National Laboratory Jennifer Carpena-Nunez National Research Council 9 March 2017 Interim Report...Distribution Statement A. Approved for public release: distribution unlimited. © 2017 AIP PUBLISHING (STINFO COPY) AIR FORCE RESEARCH
Cusick, Kathleen D; Dale, Jason R; Little, Brenda J; Biffinger, Justin C
2016-11-23
Alteromonas macleodii is a marine bacterium involved in the early stages of biofouling on ship hulls treated with copper as an antifouling agent. We report here the draft genome sequences of an A. macleodii strain isolated from copper coupons and three laboratory mutants grown long-term at elevated copper levels. Copyright © 2016 Cusick et al.
Radionuclide concentrations in honey bees from Area G at TA-54 during 1997. Progress report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haarmann, T.K.; Fresquez, P.R.
Honey bees were collected from two colonies located at Los Alamos National Laboratory`s Area G, Technical Area 54, and from one control (background) colony located near Jamez Springs, NM. Samples were analyzed for the following: cesium ({sup 137}Cs), americium ({sup 241}Am), plutonium ({sup 238}Pu and {sup 239,240}Pu), tritium ({sup 3}H), total uranium, and gross gamma activity. Area G sample results from both colonies were higher than the upper (95%) level background concentration for {sup 238}Pu and {sup 3}H.
Soria, Alessandro; Alteri, Claudia; Scarlatti, Gabriella; Bertoli, Ada; Tolazzi, Monica; Balestra, Emanuela; Bellocchi, Maria Concetta; Continenza, Fabio; Carioti, Luca; Biasin, Mara; Trabattoni, Daria; Bandera, Alessandra; Ceccherini-Silberstein, Francesca; Perno, Carlo Federico; Gori, Andrea
2017-03-15
A laboratory worker was infected with human immunodeficiency virus (HIV) type 1 in a biosafety level 2 containment facility, without any apparent breach. Through full-genome sequencing and phylogenetic analyses, we could identify the source of infection in a replication-competent clone that unknowingly contaminated a safe experiment. Mode of transmission remains unclear. Caution is warranted when handling HIV-derived constructs. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.
Characterization of university-level introductory genetics courses in Canada.
Haffie, T L; Reitmeier, Y M; Walden, D B
2000-02-01
We conducted survey research with the intent to characterize post-secondary introductory genetics (IG) education in Canada during the 1996-1997 academic year. At least a minimum data set was obtained from 47 institutions through responses to a mailed questionnaire and on-line resources. The total reported enrollment (TRE) for IG was 10,500. Over half of the TRE used one particular text. A core curriculum of topics was identified as those given more than 30 min of lecture time in at least half of reporting institutions. Slightly more than half of the TRE had laboratory exercises associated with their IG course. Laboratory exercises tended to emphasize classical transmission genetics with very few exercises in molecular genetics. For the determination of academic equivalency between institutions, particular attention should be given to the breadth and duration of the tutorial and (or) laboratory components. The majority of personnel teaching IG were trained in Canada within the previous 15 years. We suggest mechanisms by which the Genetics Society of Canada could work to promote genetical literacy.
46 CFR 164.009-21 - Laboratory report.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 6 2011-10-01 2011-10-01 false Laboratory report. 164.009-21 Section 164.009-21 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL MATERIALS Noncombustible Materials for Merchant Vessels § 164.009-21 Laboratory report. The laboratory report of the test...
46 CFR 164.009-21 - Laboratory report.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 6 2013-10-01 2013-10-01 false Laboratory report. 164.009-21 Section 164.009-21 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL MATERIALS Noncombustible Materials for Merchant Vessels § 164.009-21 Laboratory report. The laboratory report of the test...
46 CFR 164.009-21 - Laboratory report.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 6 2014-10-01 2014-10-01 false Laboratory report. 164.009-21 Section 164.009-21 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL MATERIALS Noncombustible Materials for Merchant Vessels § 164.009-21 Laboratory report. The laboratory report of the test...
46 CFR 164.009-21 - Laboratory report.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 6 2012-10-01 2012-10-01 false Laboratory report. 164.009-21 Section 164.009-21 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL MATERIALS Noncombustible Materials for Merchant Vessels § 164.009-21 Laboratory report. The laboratory report of the test...
Almeneessier, Aljohara S; Bahammam, Ahmed S; Sharif, Munir M; Bahammam, Salman A; Nashwan, Samar Z; Pandi Perumal, Seithikurippu R; Cardinali, Daniel P; Alzoghaibi, Mohammad
2017-01-01
We hypothesized that if we control for food composition, caloric intake, light exposure, sleep schedule, and exercise, intermittent fasting would not influence the circadian pattern of melatonin. Therefore, we designed this study to assess the effect of intermittent fasting on the circadian pattern of melatonin. Eight healthy volunteers with a mean age of 26.6 ± 4.9 years and body mass index of 23.7 ± 3.5 kg/m 2 reported to the Sleep Disorders Center (the laboratory) on four occasions: (1) adaptation, (2) 4 weeks before Ramadan while performing Islamic intermittent fasting for 1 week (fasting outside Ramadan [FOR]), (3) 1 week before Ramadan (nonfasting baseline [BL]), and (4) during the 2 nd week of Ramadan while fasting ( Ramadan ). The plasma levels of melatonin were measured using enzyme-linked immunoassays at 22:00, 02:00, 04:00, 06:00, and 11:00 h. The light exposure, meal composition, energy expenditure, and sleep schedules remained the same while the participants stayed at the laboratory. The melatonin levels followed the same circadian pattern during the three monitoring periods (BL, FOR, and Ramadan ). The peak melatonin level was at 02:00 h and the trough level was at 11:00 h in all studied periods. Lower melatonin levels at 22:00 h were found during fasting compared to BL. Cosinor analysis revealed no significant changes in the acrophase of melatonin levels. In this preliminary report, under controlled conditions of light exposure, meal composition, energy expenditure, and sleep-wake schedules, intermittent fasting has no significant influence on the circadian pattern of melatonin.
Almeneessier, Aljohara S.; Bahammam, Ahmed S.; Sharif, Munir M.; Bahammam, Salman A.; Nashwan, Samar Z.; Pandi Perumal, Seithikurippu R.; Cardinali, Daniel P.; Alzoghaibi, Mohammad
2017-01-01
AIMS: We hypothesized that if we control for food composition, caloric intake, light exposure, sleep schedule, and exercise, intermittent fasting would not influence the circadian pattern of melatonin. Therefore, we designed this study to assess the effect of intermittent fasting on the circadian pattern of melatonin. METHODS: Eight healthy volunteers with a mean age of 26.6 ± 4.9 years and body mass index of 23.7 ± 3.5 kg/m2 reported to the Sleep Disorders Center (the laboratory) on four occasions: (1) adaptation, (2) 4 weeks before Ramadan while performing Islamic intermittent fasting for 1 week (fasting outside Ramadan [FOR]), (3) 1 week before Ramadan (nonfasting baseline [BL]), and (4) during the 2nd week of Ramadan while fasting (Ramadan). The plasma levels of melatonin were measured using enzyme-linked immunoassays at 22:00, 02:00, 04:00, 06:00, and 11:00 h. The light exposure, meal composition, energy expenditure, and sleep schedules remained the same while the participants stayed at the laboratory. RESULTS: The melatonin levels followed the same circadian pattern during the three monitoring periods (BL, FOR, and Ramadan). The peak melatonin level was at 02:00 h and the trough level was at 11:00 h in all studied periods. Lower melatonin levels at 22:00 h were found during fasting compared to BL. Cosinor analysis revealed no significant changes in the acrophase of melatonin levels. CONCLUSIONS: In this preliminary report, under controlled conditions of light exposure, meal composition, energy expenditure, and sleep-wake schedules, intermittent fasting has no significant influence on the circadian pattern of melatonin. PMID:28808490
New frontiers in coral geochronology: advancing the state of the art
NASA Astrophysics Data System (ADS)
Thompson, William G.
2010-05-01
New developments in mass spectrometry and a better understanding of open-system processes are ushering in a new era of precision and accuracy in coral geochronology. An effort is underway to develop a uniform set of reference materials and reporting standards to assure age comparability between laboratories and eliminate inter-laboratory and age interpretation biases. PALSEA is a PAGES/IMAGES working group that aims to extract information about ice sheet response to temperature change by examining the history of sea during past interglacials. As reef-building corals are one of the primary archives of past sea levels, the U-series coral dating community is well represented in this group. During workshop discussions, it became clear that further progress on the sea level problem requires engaging the coral dating community in a cooperative standardization effort. Improvements in analytical precision continue to extend the potential precision and range of the U-Th chronometer. As a result, assuring comparability of ages reported by different labs becomes a crucial issue. Ideally, all measurements should be traceable to the same set of reference standards. Unfortunately, internationally recognized standards are not currently available. A widely used U/Th uraninite standard, HU-1, is no longer be suitable, as different aliquots have different isotope ratios and the assumption of radioactive equilibrium no longer appears valid when measured at current levels of precision. The time is ripe for the development of new reference standards. A strategy for their production and distribution has been initiated in collaboration with the NERC Isotope Geosciences Laboratory, UK, and drawing on the experiences of the EARTHTIME initiative (http://www.earth-time.org). Quaternary sea level data is presently scattered across the scientific literature with widely varying reporting formats, screening and correction criteria, and decay constants. Stratigraphic information is often incomplete, and elevations are not tied to consistent benchmarks. It would be highly desirable to compile existing data in a uniform format that can be made available to the wider community, and to adopt a uniform set of standards for future data reporting. While best practices for sample screening and/or age correction are still keenly debated, reported ages depend heavily on assumptions about the 234U/238U history of seawater over the last 800 thousand years. A standard history of ocean 234U/238U for quality and correction criteria, with associated error estimates, would make ages reported by different labs more directly comparable. Data reduction and archiving software has been developed as part of the EARTHTIME project, and discussions are underway to adapt this software for the U-Th chronometer. Standardized reporting through data reduction and databasing software has great potential to make U-series dating of coral sea-level indicators more useful and accessible to the wider paleoclimate community.
Motion as motivation: using repetitive flexion movements to stimulate the approach system.
Haeffel, Gerald J
2011-12-01
Research suggests that having a healthy approach system is critical for adaptive emotional functioning. The goal of the current study (n=186 undergraduates) was to determine the efficacy of an easy-to-disseminate and cost-efficient strategy for stimulating this system. The experiment tested the effects of repeated flexion movements (rFM) on approach system activation as measured by both self-report (BAS scales) and behavior. The results showed that rFM increased approach system motivation in men but not women. Men who completed the rFM task reported significantly greater levels of fun-seeking motivation than men in the control task. Moreover, the rFM task led to changes in actual behavior. Men who completed the rFM task exhibited significantly greater persistence on a difficult laboratory task than men in the control task. In contrast, women who completed the rFM task reported significantly lower levels of fun seeking and tended to exhibit less persistence on a difficult laboratory task than women in the control task. These results provide support for embodied theories of emotion as well as additional evidence for a gender difference in approach-avoidance tendencies. Copyright © 2011. Published by Elsevier Ltd.
Blum, C; Zillikens, D; Tony, H P; Hartmann, A A; Burg, G
1993-05-01
The evaluation of disease activity in systemic lupus erythematosus (SLE) is important for selection of the appropriate therapeutic regimen. In addition to the clinical picture, various laboratory parameters are taken into account. However, no validated criteria for the evaluation of the disease activity in SLE have yet been established. Recently, serum levels of soluble interleukin-2 receptor (sIL-2R) have been proposed as a potential parameter for disease activity in SLE. However, the studies reported on this subject so far have focused mainly on certain subsets of the disease, and the evaluation of the disease activity was based on a very limited number of parameters. In the present study, we determined serum levels of sIL-2R in 23 patients with SLE and 30 patients with discoid LE (DLE). Evaluation of disease activity in SLE was based on a comprehensive scale which considered numerous clinical signs and laboratory parameters. In SLE, serum levels of sIL-2R showed a better correlation with disease activity than all the other parameters investigated, including proteinuria, erythrocyte sedimentation rate, serum globulin concentration, titre of antibodies against double-stranded DNA, serum albumin concentration, serum complement levels and white blood cell count. For the first time, we report on elevated serum levels of sIL-2R in DLE, which also correlated with disease activity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marietta, Melvin Gary; Anderson, D. Richard; Bonano, Evaristo J.
2011-11-01
Sandia National Laboratories (SNL) is the world leader in the development of the detailed science underpinning the application of a probabilistic risk assessment methodology, referred to in this report as performance assessment (PA), for (1) understanding and forecasting the long-term behavior of a radioactive waste disposal system, (2) estimating the ability of the disposal system and its various components to isolate the waste, (3) developing regulations, (4) implementing programs to estimate the safety that the system can afford to individuals and to the environment, and (5) demonstrating compliance with the attendant regulatory requirements. This report documents the evolution of themore » SNL PA methodology from inception in the mid-1970s, summarizing major SNL PA applications including: the Subseabed Disposal Project PAs for high-level radioactive waste; the Waste Isolation Pilot Plant PAs for disposal of defense transuranic waste; the Yucca Mountain Project total system PAs for deep geologic disposal of spent nuclear fuel and high-level radioactive waste; PAs for the Greater Confinement Borehole Disposal boreholes at the Nevada National Security Site; and PA evaluations for disposal of high-level wastes and Department of Energy spent nuclear fuels stored at Idaho National Laboratory. In addition, the report summarizes smaller PA programs for long-term cover systems implemented for the Monticello, Utah, mill-tailings repository; a PA for the SNL Mixed Waste Landfill in support of environmental restoration; PA support for radioactive waste management efforts in Egypt, Iraq, and Taiwan; and, most recently, PAs for analysis of alternative high-level radioactive waste disposal strategies including repositories deep borehole disposal and geologic repositories in shale and granite. Finally, this report summarizes the extension of the PA methodology for radioactive waste disposal toward development of an enhanced PA system for carbon sequestration and storage systems. These efforts have produced a generic PA methodology for the evaluation of waste management systems that has gained wide acceptance within the international community. This report documents how this methodology has been used as an effective management tool to evaluate different disposal designs and sites; inform development of regulatory requirements; identify, prioritize, and guide research aimed at reducing uncertainties for objective estimations of risk; and support safety assessments.« less
Intertester reliability of the acceptable noise level.
Gordon-Hickey, Susan; Adams, Elizabeth; Moore, Robert; Gaal, Ashley; Berry, Katie; Brock, Sommer
2012-01-01
The acceptable noise level (ANL) serves to accurately predict the listener's likelihood of success with amplification. It has been proposed as a pre-hearing aid fitting protocol for hearing aid selection and counseling purposes. The ANL is a subjective measure of the listener's ability to accept background noise. Measurement of ANL relies on the tester and listener to follow the instructions set forth. To date, no research has explored the reliability of ANL as measured across clinicians or testers. To examine the intertester reliability of ANL. A descriptive quasi-experimental reliability study was completed. ANL was measured for one group of listeners by three testers. Three participants served as testers. Each tester was familiar with basic audiometry. Twenty-five young adults with normal hearing served as listeners. Each tester was stationed in a laboratory with the needed equipment. Listeners were instructed to report to these laboratories in a random order provided by the experimenters. The testers assessed most comfortable listening level (MCL) and background noise level (BNL) for all 25 listeners. Intraclass correlation coefficients were significant and revealed that MCL, BNL, and ANLs are reliable across testers. Additionally, one-way ANOVAs for MCL, BNL, and ANL were not significant. These findings indicate that MCL, BNL, and ANL do not differ significantly when measured by different testers. If the ANL instruction set is accurately followed, ANL can be reliably measured across testers, laboratories, and clinics. Intertester reliability of ANL allows for comparison across ANLs measured by different individuals. Findings of the present study indicate that tester reliability can be ruled out as a factor contributing to the disparity of mean ANLs reported in the literature. American Academy of Audiology.
Outcomes After Shoulder and Elbow Injury in Baseball Players: Are We Reporting What Matters?
Makhni, Eric C; Saltzman, Bryan M; Meyer, Maximilian A; Moutzouros, Vasilios; Cole, Brian J; Romeo, Anthony A; Verma, Nikhil N
2017-02-01
Return to play, as well as time to return to play, are the most important metrics considered by athletes when attempting to make treatment decisions after injury. However, the consistency of reporting of these metrics in the scientific literature is unknown. To investigate patterns of outcomes reporting in the medical literature of shoulder and elbow injuries in active baseball players. Systematic review. A systematic review of literature published within the past 10 years was performed to identify all recent clinical studies focusing on shoulder and elbow injuries in baseball players across all levels. Review articles, case reports, and laboratory/biomechanical studies were all excluded. A total of 49 studies were included for review. The majority of studies were either level 3 or level 4 evidence (96%). In total, 71% of studies reported on rates of return to preinjury level of play, whereas 31% of studies reported on time to return to preinjury level of play. Only 47% of studies reported on both rate and time of return to preinjury level of play. A minority of studies (8%) reported patient satisfaction rates. Finally, 27 different subjective and patient-reported outcomes were reported, and none of these appeared in more than 14% of all studies. Time to return to preinjury level of play is inadequately reported in studies of shoulder and elbow injury in baseball players. Similarly, satisfaction rates and scores are underreported. Finally, the significant variability of subjective and patient-reported outcomes utilized may undermine the ability of clinicians to accurately compare results from different studies.
Visual Detection, Identification, and Localization: An Annotated Bibliography.
ERIC Educational Resources Information Center
Lyman, Bernard
This annotated bibliography containing research on visual perception executed at photopic levels in artificial laboratory situations has been compiled to make information available that can be applied to scotopic perception of natural objects in natural situations. There are 407 reports or studies, published from 1945 through 1964, cited in this…
Calvet, Guilherme A; Filippis, Ana Maria B; Mendonça, Marcos Cesar L; Sequeira, Patricia C; Siqueira, Andre M; Veloso, Valdilea G; Nogueira, Rita M; Brasil, Patrícia
2016-01-01
Since May 2015, Brazil's Ministry of Health has reported autochthonous transmission of Zika virus (ZIKV) in some states of the country. Simultaneous circulation of Dengue, Chikungunya and ZIKV in the country hinder both the diagnosis and the therapeutic approach of patients seeking care with acute febrile illnesses especially in patients with comorbidities. The association between HIV infection and endemic diseases has been described especially in tropical regions with varying levels of complications, although there has been no report of ZIKV in HIV-infected patients. We report the first autochthonous case of laboratory confirmed ZIKV infection in a HIV-infected patient in Rio de Janeiro, Brazil. He evolved with only mild symptoms and recovered well without major laboratory abnormalities. Phylogenetic analysis of the ZIKV detected in the patient sera clustered within the Asian clade. To the best of our knowledge, this is the first time that Zika virus co-infection is reported in a HIV-infected patient. Copyright © 2015 Elsevier B.V. All rights reserved.
Performance testing of radiobioassay laboratories: In vivo measurements, Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
MacLellan, J.A.; Traub, R.J.; Olsen, P.C.
1990-04-01
A study of two rounds of in vivo laboratory performance testing was undertaken by Pacific Northwest Laboratory (PNL) to determine the appropriateness of the in vivo performance criteria of draft American National Standards Institute (ANSI) standard ANSI N13.3, Performance Criteria for Bioassay.'' The draft standard provides guidance to in vivo counting facilities regarding the sensitivity, precision, and accuracy of measurements for certain categories of commonly assayed radionuclides and critical regions of the body. This report concludes the testing program by presenting the results of the Round Two testing. Testing involved two types of measurements: chest counting for radionuclide detection inmore » the lung, and whole body counting for detection of uniformly distributed material. Each type of measurement was further divided into radionuclide categories as defined in the draft standard. The appropriateness of the draft standard criteria by measuring a laboratory's ability to attain them were judged by the results of both round One and Round Two testing. The testing determined that performance criteria are set at attainable levels, and the majority of in vivo monitoring facilities passed the criteria when complete results were submitted. 18 refs., 18 figs., 15 tabs.« less
Health status of copper refinery workers with specific reference to selenium exposure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holness, D.L.; Taraschuk, I.G.; Nethercott, J.R.
1989-09-01
Copper refinery workers exposed to selenium were studied before, during, and after a shutdown period. Urine selenium levels were 83 {plus minus} 30 mumol/mol creatinine and 69 {plus minus} 27 mumol/mol creatinine when measured on two occasions during exposure compared with 56 {plus minus} 17 mumol/mol creatinine when the workers had been free of exposure for 10 wk during a shutdown. The refinery workers reported more nose and eye irritation, indigestion, stomach pain, and fatigue than controls. Garlic-like breath odor was reported to be personally and socially offensive by many of the workers. Reporting of symptoms, pulmonary function indices, andmore » laboratory test results did not change with exposure except for hemoglobin level, which rose during the shutdown. Hemoglobin levels were found to be inversely correlated with the urine selenium level, and there was a positive correlation noted for the interactive effect of urine selenium and urine arsenic levels on hemoglobin.49 references.« less
The impact of SciDAC on US climate change research and the IPCCAR4
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wehner, Michael
2005-07-08
SciDAC has invested heavily in climate change research. We offer a candid opinion as to the impact of the DOE laboratories' SciDAC projects on the upcoming Fourth Assessment Report of the Intergovernmental Panel on Climate Change. As a result of the direct importance of climate change to society, climate change research is highly coordinated at the international level. The Intergovernmental Panel on Climate Change (IPCC) is charged with providing regular reports on the state of climate change research to government policymakers. These reports are the product of thousands of scientists efforts. A series of reviews involving both scientists and policymakersmore » make them among the most reviewed documents produced in any scientific field. The high profile of these reports acts a driver to many researchers in the climate sciences. The Fourth Assessment Report (AR4) is scheduled to be released in 2007. SciDAC sponsored research has enabled the United States climate modeling community to make significant contributions to this report. Two large multi-Laboratory SciDAC projects are directly relevant to the activities of the IPCC. The first, entitled ''Collaborative Design and Development of the Community Climate System Model for Terascale Computers'', has made important software contributions to the recently released third version of the Community Climate System Model (CCSM3.0) developed at the National Center for Atmospheric Research. This is a multi-institutional project involving Los Alamos National Laboratory, Oak Ridge National Laboratory, Lawrence Berkeley National Laboratory, Pacific Northwest National Laboratory, Argonne National Laboratory, Lawrence Livermore National Laboratory and the National Center for Atmospheric Research. The original principal investigators were Robert Malone and John B. Drake. The current principal investigators are Phil Jones and John B. Drake. The second project, entitled ''Earth System Grid II: Turning Climate Datasets into Community Resources'' aims to facilitate the distribution of the copious amounts of data produced by coupled climate model integrations to the general scientific community. This is also a multi-institutional project involving Argonne National Laboratory, Oak Ridge National Laboratory, Lawrence Berkeley National Laboratory, Lawrence Livermore National Laboratory and the National Center for Atmospheric Research. The principal investigators are Ian Foster, Don Middleton and Dean Williams. Perhaps most significant among the activities of the ''Collaborative Design'', project was the development of an efficient multi-processor coupling package. CCSM3.0 is an extraordinarily complicated physics code. The fully coupled model consists of separate submodels of the atmosphere, ocean, sea ice and land. In addition, comprehensive biogeochemistry and atmospheric chemistry submodels are under intensive current development. Each of these submodels is a large and sophisticated program in its own right. Furthermore, in the coupled model, each of the submodels, including the coupler, is a separate multiprocessor executable program. The coupler package must efficiently coordinate the communication as well as interpolate or aggregate information between these programs. This regridding function is necessary because each major subsystem (air, water or surface) is allowed to have its own independent grid.« less
Namkoong, Sun; Hong, Seung Phil; Kim, Myung Hwa; Park, Byung Cheol
2013-02-01
Nowadays, although its clinical value remains controversial institutions utilize hair mineral analysis. Arguments about the reliability of hair mineral analysis persist, and there have been evaluations of commercial laboratories performing hair mineral analysis. The objective of this study was to assess the reliability of intra-laboratory and inter-laboratory data at three commercial laboratories conducting hair mineral analysis, compared to serum mineral analysis. Two divided hair samples taken from near the scalp were submitted for analysis at the same time, to all laboratories, from one healthy volunteer. Each laboratory sent a report consisting of quantitative results and their interpretation of health implications. Differences among intra-laboratory and interlaboratory data were analyzed using SPSS version 12.0 (SPSS Inc., USA). All the laboratories used identical methods for quantitative analysis, and they generated consistent numerical results according to Friedman analysis of variance. However, the normal reference ranges of each laboratory varied. As such, each laboratory interpreted the patient's health differently. On intra-laboratory data, Wilcoxon analysis suggested they generated relatively coherent data, but laboratory B could not in one element, so its reliability was doubtful. In comparison with the blood test, laboratory C generated identical results, but not laboratory A and B. Hair mineral analysis has its limitations, considering the reliability of inter and intra laboratory analysis comparing with blood analysis. As such, clinicians should be cautious when applying hair mineral analysis as an ancillary tool. Each laboratory included in this study requires continuous refinement from now on for inducing standardized normal reference levels.
Zarbo, Richard J; Nakhleh, Raouf E; Walsh, Molly
2003-01-01
Measurement of physicians' and patients' satisfaction with laboratory services has recently become a requirement of health care accreditation agencies in the United States. To our knowledge, this is the first customer satisfaction survey of anatomic pathology services to provide a standardized tool and benchmarks for subsequent measures of satisfaction. This Q-Probes study assessed physician satisfaction with anatomic pathology laboratory services and sought to determine characteristics that correlate with a high level of physician satisfaction. In January 2001, each laboratory used standardized survey forms to assess physician customer satisfaction with 10 specific elements of service in anatomic pathology and an overall satisfaction rating based on a scale of rankings from a 5 for excellent to a 1 for poor. Data from up to 50 surveys returned per laboratory were compiled and analyzed by the College of American Pathologists. A general questionnaire collected information about types of services offered and each laboratory's quality assurance initiatives to determine characteristics that correlate with a high level of physician satisfaction. Hospital-based laboratories in the United States (95.8%), as well as others from Canada and Australia. Ninety-four voluntary subscriber laboratories in the College of American Pathologists Q-Probes quality improvement program participated in this survey. Roughly 70% of respondents were from hospitals with occupied bedsizes of 300 or less, 65% were private nonprofit institutions, just over half were located in cities, one third were teaching hospitals, and 19% had pathology residency training programs. Overall physician satisfaction with anatomic pathology and 10 selected aspects of the laboratory service (professional interaction, diagnostic accuracy, pathologist responsiveness to problems, pathologist accessibility for frozen section, tumor board presentations, courtesy of secretarial and technical staff, communication of relevant information, teaching conferences and courses, notification of significant abnormal results, and timeliness of reporting). The database of 3065 physician surveys was derived from 94 laboratories. An average of 32.6 surveys (median 30) was returned per institution, with a range of 5 to 50 surveys per institution. The mean response rate was 35.6% (median 32.5%). The median (50th percentile) laboratory had an overall median satisfaction score of 4.4. The lowest satisfaction scores that were obtained all related to poor communication, which included timeliness of reporting, communication of relevant information, and notification of significant abnormal results. Statistically significant associations of customer satisfaction with certain institutional characteristics and laboratory performance improvement activities were identified. The importance of this satisfaction survey lies not in its requirement as an exercise for accrediting agencies but in understanding the needs of the customer (in this case the physician) to direct performance improvement in the delivery of quality anatomic pathology laboratory services.
Lupus anticoagulant: a multicenter study for a standardized and harmonized reporting.
Poz, Alessandra; Pradella, Paola; Azzarini, Gabriella; Santarossa, Liliana; Bardin, Cristina; Zardo, Lorena; Giacomello, Roberta
2016-03-01
Laboratory assessment of Lupus anticoagulant (LAC) is very challenging because of inter and intralaboratory variability, which makes it difficult to standardize and harmonize results expression. Five hospital laboratories in North-eastern Italy shared their efforts and their experience in a cross-laboratory study, conducting the diagnostic process as homogeneously as possible and providing a better interpretation for LAC positivity. Hundred normal samples from healthy subjects (20 from each center) were processed to confirm negative upper limits and calculate positivity cutoffs of LAC integrated assays, that is dilute Russell's viper venom time (dRVVT) and silica clotting time (SCT). Moreover, 311 samples previously diagnosed by the laboratories as positive for LAC were analyzed to characterize different positivity levels for each assay. As far as the analysis of healthy subjects is concerned, negative upper limits are set at 1.17 and 1.19 for dRVVT and SCT screen ratio, respectively. Positivity cutoffs are set at 1.20 for dRVVT and 1.23 for SCT, expressed as Test Ratio calculated on screen and confirm integrated tests. Positive results for each integrated assay are subsequently divided into three subgroups: weak, moderate and strong; the results obtained are presented as a score proposal that can provide LAC interpretation. The combined use of both dRVVT and SCT assays and the definition of different positivity levels may lead to clearer, more objective LAC reporting. An interpretative table for LAC-proposed score provides LAC-positive results and it is now adopted by all centers involved in the study.
Johnson, Matthew G; Williams, Jean; Lee, Anthony; Bradley, Kristy K
2014-05-01
The Health Information Technology for Economic and Clinical Health (HITECH) Act encourages the meaningful use of certified electronic health record technology. A HITECH-compliant core component is nationwide electronic laboratory reporting (ELR) implementation for communicable disease surveillance. In Oklahoma, laboratories with ≥400 positive tests/year for reportable diseases must use ELR. Of 18 such laboratories, two have adopted ELR. We compared completeness and timeliness of ELR reports from these two laboratories with conventional reports from all other Oklahoma laboratories. We retrospectively reviewed confirmed reportable disease cases for January 1-December 31, 2011, excluding tuberculosis, hepatitis, sexually transmitted infections, diseases without laboratory diagnoses, and immediately reportable diseases. Probable reportable tickborne disease cases were included. We compared ELR with conventional reporting (i.e., mail, fax, telephone, and Internet). We assessed data completeness based on eight demographic and two laboratory fields in each disease report and timeliness by percentage of cases reported in ≤1 business day. Overall, 1,867 reports met the inclusion criteria; 24% of these reports had been submitted by ELR. Data completeness was 90% for ELR and 95% for conventional reporting. Patient addresses accounted for 97% of the missing data fields for ELR reports. Timeliness was 91% for ELR and 87% for conventional reports. Although early in the transition to ELR compliance in Oklahoma, ELR has already yielded improved timeliness for communicable disease surveillance. However, ELR did not yield more complete reports than conventional reporting. Requiring specific demographic data fields for ELR reports can improve the completeness of ELR.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fabrikant, J.I.
1981-04-01
General background is given for an understanding of the potential health effects in populations exposed to low-level ionizing radiations. The discussion is within the framework of the scientific deliberations and controversies that arose during preparation of the current report of the committee on the biological effects of ionizing radiation of the National Academy of Science - National Research Council (1980 Beir-III Report). (ACR)
Rylands, Lee P; Roberts, Simon J; Hurst, Howard T
2015-09-01
The aim of this study was to ascertain the variation in elite male bicycle motocross (BMX) cyclists' peak power, torque, and time of power production during laboratory and field-based testing. Eight elite male BMX riders volunteered for the study, and each rider completed 3 maximal sprints using both a Schoberer Rad Messtechnik (SRM) ergometer in the laboratory and a portable SRM power meter on an Olympic standard indoor BMX track. The results revealed a significantly higher peak power (p ≤ 0.001, 34 ± 9%) and reduced time of power production (p ≤ 0.001, 105 ± 24%) in the field tests when compared with laboratory-derived values. Torque was also reported to be lower in the laboratory tests but not to an accepted level of significance (p = 0.182, 6 ± 8%). These results suggest that field-based testing may be a more effective and accurate measure of a BMX rider's peak power, torque, and time of power production.
The assessment of data sources for influenza virologic surveillance in New York State.
Escuyer, Kay L; Waters, Christine L; Gowie, Donna L; Maxted, Angie M; Farrell, Gregory M; Fuschino, Meghan E; St George, Kirsten
2017-03-01
Following the 2013 USA release of the Influenza Virologic Surveillance Right Size Roadmap, the New York State Department of Health (NYSDOH) embarked on an evaluation of data sources for influenza virologic surveillance. To assess NYS data sources, additional to data generated by the state public health laboratory (PHL), which could enhance influenza surveillance at the state and national level. Potential sources of laboratory test data for influenza were analyzed for quantity and quality. Computer models, designed to assess sample sizes and the confidence of data for statistical representation of influenza activity, were used to compare PHL test data to results from clinical and commercial laboratories, reported between June 8, 2013 and May 31, 2014. Sample sizes tested for influenza at the state PHL were sufficient for situational awareness surveillance with optimal confidence levels, only during peak weeks of the influenza season. Influenza data pooled from NYS PHLs and clinical laboratories generated optimal confidence levels for situational awareness throughout the influenza season. For novel influenza virus detection in NYS, combined real-time (rt) RT-PCR data from state and regional PHLs achieved ≥85% confidence during peak influenza activity, and ≥95% confidence for most of low season and all of off-season. In NYS, combined data from clinical, commercial, and public health laboratories generated optimal influenza surveillance for situational awareness throughout the season. Statistical confidence for novel virus detection, which is reliant on only PHL data, was achieved for most of the year. © 2016 The Authors. Influenza and Other Respiratory Viruses Published by John Wiley & Sons Ltd.
Geldner, G; Koch, E M; Gottwald-Hostalek, U; Baud, F; Burillo, G; Fauville, J-P; Levi, F; Locatelli, C; Zilker, T
2013-08-01
This is a report on an international non-interventional study of patients exposed to fires with smoke development in closed rooms. The objective of the study was to document clinical symptoms, relevant laboratory values and blood cyanide concentrations from fire victims in order to confirm or rule out presumptive correlations between the individual parameters. The study was conducted in five European countries with patients being included if they presented with the characteristic clinical signs, such as soot deposits and altered neurological status. Venous blood samples were taken from victims prior to administration of an antidote in all cases and determination of cyanide concentration was performed in a central laboratory using high performance liquid chromatography. Data from 102 patients (62 % male, average age 49 years) were included in the evaluation with no blood samples being available for analysis from 2 patients. In 25 patients the blood cyanide concentration was below the limit of detection of 1.2 μmol/l. Cyanide levels between 1.2 and 10 μmol/l were measured in 54 patients, 7 patients had values between 10 and 20 μmol/l, 4 patients between 20 and 40 μmol/l while levels above 40 μmol/l were determined in 10 patients. The results of the study could not demonstrate that the cyanide level was influenced either by the interval between smoke exposure and blood sampling or the duration presence at the fire scene. The following clinical signs or laboratory values were recorded as relevant for increased and possibly toxic cyanide levels: respiratory arrest, dyspnea, resuscitation requirement, tracheal intubation, respiratory support measures, low Glasgow coma scale (GCS) score and respiratory frequency. A correlation between cyanide concentration and the total amount of soot deposits on the face and neck, in the oral cavity and in expectoration was confirmed. A correlation between cyanide and carboxyhemoglobin (COHb) levels in the blood of fire victims was also confirmed. As long as it is not possible to immediately determine the blood cyanide concentration in patients exposed to fire with smoke development, a decreased GCS score, soot deposits particularly in expectoration, dyspnea and convulsions are to be regarded as risk markers for intoxication. In their presence immediate administration of hydroxocobalamin as an antidote is recommended.
FY 2017-Influence of Sodium Environment on the Tensile Properties of Advanced Alloys
DOE Office of Scientific and Technical Information (OSTI.GOV)
Natesan, K.; Li, Meimei; Chen, Wei-Ying
This report provides an update on the understanding of the effects of sodium exposures on tensile properties of advanced alloy 709 in support of the design and operation of structural components in sodium-cooled fast reactors (SFRs). The report is a Level 3 deliverable in FY17 (M3AT-17AN1602093), under the Work Package AT-17AN160209, “Sodium Compatibility” performed by Argonne National Laboratory (ANL), as part of Advanced Reactor Technologies Program. Three laboratory-size heats of Alloy 709 austenitic steel were investigated in liquid sodium environments at 550-650°C to understand its corrosion behaviour, microstructural evolution, and tensile properties. In addition, a commercial scale heat has beenmore » produced and hot-rolled into plates.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
NREL's Sustainability Program is responsible for upholding all executive orders, federal regulations, U.S. Department of Energy (DOE) orders, and goals related to sustainable and resilient facility operations. But NREL continues to expand sustainable practices above and beyond the laboratory's regulations and requirements to ensure that the laboratory fulfills its mission into the future, leaves the smallest possible legacy footprint, and models sustainable operations and behaviors on national, regional, and local levels. The report, per the GRI reporting format, elaborates on multi-year goals relative to executive orders, achievements, and challenges; and success stories provide specific examples. A section called 'NREL's Resiliencymore » is Taking Many Forms' provides insight into how NREL is drawing on its deep knowledge of renewable energy and energy efficiency to help mitigate or avoid climate change impacts.« less
Refeeding syndrome or refeeding hypophosphatemia: a systematic review of cases.
Skipper, Annalynn
2012-02-01
Nutrition support clinicians refer to the abnormalities in laboratory data and changes in clinical signs and symptoms that follow refeeding of starved or malnourished patients as refeeding syndrome. Theoretical descriptions of refeeding syndrome include a complex and extensive list of changes, such as hypophosphatemia, hypomagnesemia, hypokalemia, hyponatremia, hypocalcemia, hyperglycemia, and vitamin deficiency--all of which are accompanied by clinical signs and symptoms. In practice, clinicians see asymptomatic refeeding hypophosphatemia more often than a full-blown syndrome with multiple laboratory and clinical abnormalities. Confusion results because there is no widely accepted or uniformly applied set of defining characteristics for diagnosing refeeding syndrome. To gain insight into the clinical characteristics of refeeding syndrome described in the literature, a systematic review of reported cases and case series was conducted. Since 2000, 20 authors described 27 cases that contained sufficient data for review. Hypophosphatemia occurred in 26 patients (96%). While 19 patients (71%) experienced at least 1 other laboratory abnormality, only 14 (51%) exhibited a consistent pattern of abnormally low phosphorus and magnesium levels. Seven patients had hypocalcemia (26%), and hyponatremia was reported in 3 patients (11%). There were no reports of hyperglycemia. Mean data reported in case series containing data from 63 patients showed that hypophosphatemia was a consistent finding but that other abnormalities were not consistently identified. Findings suggest that refeeding hypophosphatemia is not accompanied by a consistent pattern of biochemical or clinical abnormalities among case reports or case series of patients reported to have refeeding syndrome.
The laboratory diagnosis of testosterone deficiency.
Paduch, Darius A; Brannigan, Robert E; Fuchs, Eugene F; Kim, Edward D; Marmar, Joel L; Sandlow, Jay I
2014-05-01
The evaluation and treatment of hypogonadal men has become an important part of urologic practice. Fatigue, loss of libido, and erectile dysfunction are commonly reported, but nonspecific symptoms and laboratory verification of low testosterone (T) are an important part of evaluation in addition to a detailed history and physical examination. Significant intraindividual fluctuations in serum T levels, biologic variation of T action on end organs, the wide range of T levels in human serum samples, and technical limitations of currently available assays have led to poor reliability of T measurements in the clinical laboratory setting. There is no universally accepted threshold of T concentration that distinguishes eugonadal from hypogonadal men; thus, laboratory results have to be interpreted in the appropriate clinical setting. This review focuses on clinical, biological, and technological challenges that affect serum T measurements to educate clinicians regarding technological advances and limitations of the currently available laboratory methods to diagnose hypogonadism. A collaborative effort led by the American Urological Association between practicing clinicians, patient advocacy groups, government regulatory agencies, industry, and professional societies is underway to provide optimized assay platforms and evidence-based normal assay ranges to guide clinical decision making. Until such standardization is commonplace in clinical laboratories, the decision to treat should be based on the presence of signs and symptoms in addition to serum T measurements. Rigid interpretation of T ranges should not dictate clinical decision making or define coverage of treatment by third party payers. Copyright © 2014 Elsevier Inc. All rights reserved.
Development of a low background liquid scintillation counter for a shallow underground laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erchinger, Jennifer L.; Aalseth, Craig E.; Bernacki, Bruce E.
2015-08-20
Pacific Northwest National Laboratory has recently opened a shallow underground laboratory intended for measurement of lowconcentration levels of radioactive isotopes in samples collected from the environment. The development of a low-background liquid scintillation counter is currently underway to further augment the measurement capabilities within this underground laboratory. Liquid scintillation counting is especially useful for measuring charged particle (e.g., B, a) emitting isotopes with no (orvery weak) gamma-ray yields. The combination of high-efficiency detection of charged particle emission in a liquid scintillation cocktail coupled with the low-background environment of an appropriately-designed shield located in a clean underground laboratory provides the opportunitymore » for increased-sensitivity measurements of a range of isotopes. To take advantage of the 35-meter water-equivalent overburden of the underground laboratory, a series of simulations have evaluated the instrumental shield design requirements to assess the possible background rate achievable. This report presents the design and background evaluation for a shallow underground, low background liquid scintillation counter design for sample measurements.« less
Laboratory measurement of the anticoagulant activity of the non-vitamin K oral anticoagulants.
Cuker, Adam; Siegal, Deborah M; Crowther, Mark A; Garcia, David A
2014-09-16
Non-vitamin K oral anticoagulants (NOACs) do not require routine laboratory monitoring. However, laboratory measurement may be desirable in special situations and populations. This study's objective was to systematically review and summarize current evidence regarding laboratory measurement of the anticoagulant activity of dabigatran, rivaroxaban, and apixaban. We searched PubMed and Web of Science for studies that reported a relationship between drug levels of dabigatran, rivaroxaban, and apixaban and coagulation assay results. Study quality was evaluated using QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2). We identified 17 eligible studies for dabigatran, 15 for rivaroxaban, and 4 for apixaban. For dabigatran, a normal thrombin time excludes clinically relevant drug concentrations. The activated partial thromboplastin time (APTT) and prothrombin time (PT) are less sensitive and may be normal at trough drug levels. The dilute thrombin time (R(2) = 0.92 to 0.99) and ecarin-based assays (R(2) = 0.92 to 1.00) show excellent linearity across on-therapy drug concentrations and may be used for drug quantification. For rivaroxaban and apixaban, anti-Xa activity is linear (R(2) = 0.89 to 1.00) over a wide range of drug levels and may be used for drug quantification. Undetectable anti-Xa activity likely excludes clinically relevant drug concentrations. The PT is less sensitive (especially for apixaban); a normal PT may not exclude clinically relevant levels. The APTT demonstrates insufficient sensitivity and linearity for quantification. Dabigatran, rivaroxaban, and apixaban exhibit variable effects on coagulation assays. Understanding these effects facilitates interpretation of test results in NOAC-treated patients. More information on the relationship between drug levels and clinical outcomes is needed. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1982-09-01
The U.S. Department of Energy (DOE) is considering the selection of a strategy for the long-term management of the defense high-level wastes at the Idaho Chemical Processing Plant (ICPP). This report describes the environmental impacts of alternative strategies. These alternative strategies include leaving the calcine in its present form at the Idaho National Engineering Laboratory (INEL), or retrieving and modifying the calcine to a more durable waste form and disposing of it either at the INEL or in an offsite repository. This report addresses only the alternatives for a program to manage the high-level waste generated at the ICPP. 24more » figures, 60 tables.« less
Ray, Lara A; Miranda, Robert; Tidey, Jennifer W; McGeary, John E; MacKillop, James; Gwaltney, Chad J; Rohsenow, Damaris J; Swift, Robert M; Monti, Peter M
2010-02-01
Polymorphisms of the mu-opioid receptor (OPRM1) and dopamine D4 receptor (DRD4) genes are associated with subjective responses to alcohol and urge to drink under laboratory conditions. This study examined these associations in the natural environment using ecological momentary assessment. Participants were non-treatment-seeking heavy drinkers (n = 112, 52% female, 61% alcohol dependent) who enrolled in a study of naltrexone effects on craving and drinking in the natural environment. Data were culled from 5 consecutive days of drinking reports prior to medication randomization. Analyses revealed that, after drinking, carriers of the Asp40 allele of the OPRM1 gene reported higher overall levels of vigor and lower levels negative mood, as compared to homozygotes for the Asn40 variant. Carriers of the long allele (i.e., >or=7 tandem repeats) of the DRD4 endorsed greater urge to drink than homozygotes for the short allele. Effects of OPRM1 and DRD4 variable-number-of-tandem-repeats genotypes appear to be alcohol dose-dependent. Specifically, carriers of the DRD4-L allele reported slight decreases in urge to drink at higher levels of estimated blood alcohol concentration (eBAC), and Asp40 carriers reported decreases in vigor and increases in negative mood as eBAC rose, as compared to carriers of the major allele for each gene. Self-reported vigor and urge to drink were positively associated with alcohol consumption within the same drinking episode. This study extends findings on subjective intoxication, urge to drink, and their genetic bases from controlled laboratory to naturalistic settings.
Kitchener, Henry C; Gittins, Matthew; Desai, Mina; Smith, John H F; Cook, Gary; Roberts, Chris; Turnbull, Lesley
2015-03-01
Liquid-based cytology (LBC) for cervical screening would benefit from laboratory practice guidelines that define specimen adequacy for reporting of slides. The evidence base required to define cell adequacy should incorporate both ThinPrep™ (TP; Hologic, Inc., Bedford, MA, USA) and SurePath™ (SP; BD Diagnostics, Burlington, NC, USA), the two LBC systems used in the UK cervical screening programmes. The objectives of this study were to determine (1) current practice for reporting LBC in England, Wales and Scotland, (2) a reproducible method for cell counting, (3) the cellularity of slides classified as inadequate, negative or abnormal and (4) the impact of varying cellularity on the likelihood of detecting cytological abnormalities. The study involved four separate arms to pursue each of the four objectives. (1) A questionnaire survey of laboratories was conducted. (2) A standard counting protocol was developed and used by three experienced cytopathologists to determine a reliable and reproducible cell counting method. (3) Slide sets which included a range of cytological abnormalities were each sent to three laboratories for cell counting to study the correlation between cell counts and reported cytological outcomes. (4) Dilution of LBC samples by fluid only (unmixed) or by dilution with a sample containing normal cells (mixed) was performed to study the impact on reporting of reducing either the total cell count or the relative proportion of abnormal to normal cells. The study was conducted within the cervical screening programmes in England, Wales and Scotland, using routinely obtained cervical screening samples, and in 56 participating NHS cervical cytology laboratories. The study involved only routinely obtained cervical screening samples. There was no clinical intervention. The main outcome measures were (1) reliability of counting method, (2) correlation of reported cytology grades with cellularity and (3) levels of detection of abnormal cells in progressively diluted cervical samples. Laboratory practice varied in terms of threshold of cellular adequacy and of morphological markers of adequacy. While SP laboratories generally used a minimum acceptable cell count (MACC) of 15,000, the MACC employed by TP laboratories varied between 5000 and 15,000. The cell counting study showed that a standard protocol achieved moderate to strong inter-rater reproducibility. Analysis of slide reporting from laboratories revealed that a large proportion of the samples reported as inadequate had cell counts above a threshold of 15,000 for SP, and 5000 and 10,000 for TP. Inter-rater unanimity was greater among more cellular preparations. Dilution studies demonstrated greater detection of abnormalities in slides with counts above the MACC and among slides with more than 25 dyskaryotic cells. Variation in laboratory practice demonstrates a requirement for evidence-based standards for designating a MACC. This study has indicated that a MACC of 15,000 and 5000 for SP and TP, respectively, achieves a balance in terms of maintaining sensitivity and low inadequacy rates. The findings of this study should inform the development of laboratory practice guidelines. The National Institute for Health Research Health Technology Assessment programme.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Virginia Finley
This report presents the results of environmental activities and monitoring programs at the Princeton Plasma Physics Laboratory (PPPL) for Calendar Years 2009-2010. The report provides the U.S. Department of Energy (DOE) and the public with information on the level of radioactive and non-radioactive pollutants, if any, that are released into the environment as a result of PPPL operations. The report also summarizes environmental initiatives, assessments, and programs that were undertaken in 2009-2010. The objective of the Site Environmental Report is to document PPPL's efforts to protect the public's health and the environment through its environmental protection, safety, and health programs.more » __________________________________________________« less
Electric and magnetic fields and tumor progression. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keng, P.C.; Grota, L.J.; Michaelson, S.
This laboratory study has rigorously investigated two previously reported biological effects of 60-Hz electric and magnetic fields. The first effect involves nighttime suppression of melatonin synthesis in the pineal glands of rats exposed to high electric fields. The second concerns the increase in colony forming ability of human colon cancer cells exposed to 1.4-G magnetic fields. Neither effect was detected in the present study. A series of published laboratory studies on rats reported that 60-Hz electric fields at various field levels up to 130 kV/m suppress the nighttime synthesis of melatonin, a hormone produced by the pineal gland. Since melatoninmore » is known to modulate the immune system and may inhibit cancer cell activity, changes in physiological levels of melatonin may have significant health consequences. In the repeat experiments, field exposure did not alter nighttime levels of melatonin or enzyme activities in the pineal gland. A small but statistically significant reduction of about 20% in serum melatonin was seen in exposed animals. Pineal melatonin was also unaffected by the presence of red light as a cofactor with field exposure or by time-shifting the daily field exposure period. Another study reported that 60-Hz magnetic fields can affect the colony forming ability of human cancer cells after exposure in a culture medium. In the repeat experiments, field exposure did not alter the colony forming ability of human Colo 205 cells in two different cell concentrations at plating or in two different incubation conditions. Field exposure also did not affect cell cycling in any of the four cell lines tested.« less
DOE Solar Energy Technologies Program FY 2005 Annual Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The DOE Solar Energy Technologies Program FY 2005 Annual Report chronicles the R&D results of the U.S. Department of Energy Solar Energy Technologies Program for Fiscal Year 2005. In particular, the report describes R&D performed by the Program?s national laboratories (National Renewable Energy Laboratory, Sandia National Laboratories, Oak Ridge National Laboratory, and Brookhaven National Laboratory) and university and industry partners.
Laboratory-Based Prospective Surveillance for Community Outbreaks of Shigella spp. in Argentina
Viñas, María R.; Tuduri, Ezequiel; Galar, Alicia; Yih, Katherine; Pichel, Mariana; Stelling, John; Brengi, Silvina P.; Della Gaspera, Anabella; van der Ploeg, Claudia; Bruno, Susana; Rogé, Ariel; Caffer, María I.; Kulldorff, Martin; Galas, Marcelo
2013-01-01
Background To implement effective control measures, timely outbreak detection is essential. Shigella is the most common cause of bacterial diarrhea in Argentina. Highly resistant clones of Shigella have emerged, and outbreaks have been recognized in closed settings and in whole communities. We hereby report our experience with an evolving, integrated, laboratory-based, near real-time surveillance system operating in six contiguous provinces of Argentina during April 2009 to March 2012. Methodology To detect localized shigellosis outbreaks timely, we used the prospective space-time permutation scan statistic algorithm of SaTScan, embedded in WHONET software. Twenty three laboratories sent updated Shigella data on a weekly basis to the National Reference Laboratory. Cluster detection analysis was performed at several taxonomic levels: for all Shigella spp., for serotypes within species and for antimicrobial resistance phenotypes within species. Shigella isolates associated with statistically significant signals (clusters in time/space with recurrence interval ≥365 days) were subtyped by pulsed field gel electrophoresis (PFGE) using PulseNet protocols. Principal Findings In three years of active surveillance, our system detected 32 statistically significant events, 26 of them identified before hospital staff was aware of any unexpected increase in the number of Shigella isolates. Twenty-six signals were investigated by PFGE, which confirmed a close relationship among the isolates for 22 events (84.6%). Seven events were investigated epidemiologically, which revealed links among the patients. Seventeen events were found at the resistance profile level. The system detected events of public health importance: infrequent resistance profiles, long-lasting and/or re-emergent clusters and events important for their duration or size, which were reported to local public health authorities. Conclusions/Significance The WHONET-SaTScan system may serve as a model for surveillance and can be applied to other pathogens, implemented by other networks, and scaled up to national and international levels for early detection and control of outbreaks. PMID:24349586
You, Je Sung; Chung, Yong Eun; Park, Jong Woo; Lee, Woonhyoung; Lee, Hye-Jeong; Chung, Tae Nyoung; Chung, Sung Phil; Park, Incheol; Kim, Seungho
2013-07-01
Renal dysfunction is the most important factor to consider when predicting a patient's risk of developing contrast-induced nephropathy (CIN). Measurement of creatinine (Cr) via rapid point-of-care blood urea nitrogen/creatinine testing (POCT-BUN/Cr) to determine CIN risk could potentially reduce the time required to achieve an accurate diagnosis and to initiate and complete treatment in the emergency department (ED). The aim of our study was to compare the results of POCT-BUN/Cr and reference laboratory tests for BUN and serum Cr. A retrospective analysis of suspected stroke patients who presented between November 2009 and November 2010, and had BUN and Cr levels measured by POCT-BUN/Cr, and the reference laboratory tests performed with the blood sample which was transferred to the central laboratory by an air-shoot system. Two assays were conducted on the whole blood (POCT) and serum (reference) by trained technicians. The time interval from arrival at the ED to reporting of the results was assessed for both assays via a computerised physician order entry system. The mean standard deviation (SD) interval from arrival at the ED to reporting of the results was 11.4 (4.9) min for POCT-BUN/Cr and 46.8 (38.5) min for the serum reference laboratory tests (p<0.001). Intra-class correlation coefficient (ICC) analysis demonstrated a high level of agreement (the consistency agreement) between POCT and the serum reference tests for both BUN (ICC=0.914) and Cr (ICC=0.980). This study suggests that POCT-BUN/Cr results correlate well with those of serum reference tests in terms of BUN and Cr levels and, in turn, predicting CIN. POCT-BUN/Cr is easily performed with a rapid turnaround time, suggesting its use in the ED may have substantial clinical benefit.
Laboratory-based prospective surveillance for community outbreaks of Shigella spp. in Argentina.
Viñas, María R; Tuduri, Ezequiel; Galar, Alicia; Yih, Katherine; Pichel, Mariana; Stelling, John; Brengi, Silvina P; Della Gaspera, Anabella; van der Ploeg, Claudia; Bruno, Susana; Rogé, Ariel; Caffer, María I; Kulldorff, Martin; Galas, Marcelo
2013-01-01
To implement effective control measures, timely outbreak detection is essential. Shigella is the most common cause of bacterial diarrhea in Argentina. Highly resistant clones of Shigella have emerged, and outbreaks have been recognized in closed settings and in whole communities. We hereby report our experience with an evolving, integrated, laboratory-based, near real-time surveillance system operating in six contiguous provinces of Argentina during April 2009 to March 2012. To detect localized shigellosis outbreaks timely, we used the prospective space-time permutation scan statistic algorithm of SaTScan, embedded in WHONET software. Twenty three laboratories sent updated Shigella data on a weekly basis to the National Reference Laboratory. Cluster detection analysis was performed at several taxonomic levels: for all Shigella spp., for serotypes within species and for antimicrobial resistance phenotypes within species. Shigella isolates associated with statistically significant signals (clusters in time/space with recurrence interval ≥365 days) were subtyped by pulsed field gel electrophoresis (PFGE) using PulseNet protocols. In three years of active surveillance, our system detected 32 statistically significant events, 26 of them identified before hospital staff was aware of any unexpected increase in the number of Shigella isolates. Twenty-six signals were investigated by PFGE, which confirmed a close relationship among the isolates for 22 events (84.6%). Seven events were investigated epidemiologically, which revealed links among the patients. Seventeen events were found at the resistance profile level. The system detected events of public health importance: infrequent resistance profiles, long-lasting and/or re-emergent clusters and events important for their duration or size, which were reported to local public health authorities. The WHONET-SaTScan system may serve as a model for surveillance and can be applied to other pathogens, implemented by other networks, and scaled up to national and international levels for early detection and control of outbreaks.
Smolinski, Mark S.; Olsen, Jennifer M.
2017-01-01
Rapid detection, reporting, and response to an infectious disease outbreak are critical to prevent localized health events from emerging as pandemic threats. Metrics to evaluate the timeliness of these critical activities, however, are lacking. Easily understood and comparable measures for tracking progress and encouraging investment in rapid detection, reporting, and response are sorely needed. We propose that the timeliness of outbreak detection, reporting, laboratory confirmation, response, and public communication should be considered as measures for improving global health security at the national level, allowing countries to track progress over time and inform investments in disease surveillance. PMID:28384035
Laboratory Directed Research and Development annual report, fiscal year 1997
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-03-01
The Department of Energy Order 413.2(a) establishes DOE`s policy and guidelines regarding Laboratory Directed Research and Development (LDRD) at its multiprogram laboratories. As described in 413.2, LDRD is research and development of a creative and innovative nature which is selected by the Laboratory Director or his or her designee, for the purpose of maintaining the scientific and technological vitality of the Laboratory and to respond to scientific and technological opportunities in conformance with the guidelines in this Order. DOE Order 413.2 requires that each laboratory submit an annual report on its LDRD activities to the cognizant Secretarial Officer through themore » appropriate Operations Office Manager. The report provided in this document represents Pacific Northwest National Laboratory`s LDRD report for FY 1997.« less
Improvement of the quality of work in a biochemistry laboratory via measurement system analysis.
Chen, Ming-Shu; Liao, Chen-Mao; Wu, Ming-Hsun; Lin, Chih-Ming
2016-10-31
An adequate and continuous monitoring of operational variations can effectively reduce the uncertainty and enhance the quality of laboratory reports. This study applied the evaluation rule of the measurement system analysis (MSA) method to estimate the quality of work conducted in a biochemistry laboratory. Using the gauge repeatability & reproducibility (GR&R) approach, variations in quality control (QC) data among medical technicians in conducting measurements of five biochemical items, namely, serum glucose (GLU), aspartate aminotransferase (AST), uric acid (UA), sodium (Na) and chloride (Cl), were evaluated. The measurements of the five biochemical items showed different levels of variance among the different technicians, with the variances in GLU measurements being higher than those for the other four items. The ratios of precision-to-tolerance (P/T) for Na, Cl and GLU were all above 0.5, implying inadequate gauge capability. The product variation contribution of Na was large (75.45% and 31.24% in normal and abnormal QC levels, respectively), which showed that the impact of insufficient usage of reagents could not be excluded. With regard to reproducibility, high contributions (of more than 30%) of variation for the selected items were found. These high operator variation levels implied that the possibility of inadequate gauge capacity could not be excluded. The analysis of variance (ANOVA) of GR&R showed that the operator variations in GLU measurements were significant (F=5.296, P=0.001 in the normal level and F=3.399, P=0.015 in the abnormal level, respectively). In addition to operator variations, product variations of Na were also significant for both QC levels. The heterogeneity of variance for the five technicians showed significant differences for the Na and Cl measurements in the normal QC level. The accuracy of QC for five technicians was identified for further operational improvement. This study revealed that MSA can be used to evaluate product and personnel errors and to improve the quality of work in a biochemical laboratory through proper corrective actions.
Connecting Protein Structure to Intermolecular Interactions: A Computer Modeling Laboratory
ERIC Educational Resources Information Center
Abualia, Mohammed; Schroeder, Lianne; Garcia, Megan; Daubenmire, Patrick L.; Wink, Donald J.; Clark, Ginevra A.
2016-01-01
An understanding of protein folding relies on a solid foundation of a number of critical chemical concepts, such as molecular structure, intra-/intermolecular interactions, and relating structure to function. Recent reports show that students struggle on all levels to achieve these understandings and use them in meaningful ways. Further, several…
ERIC Educational Resources Information Center
Halpern, Arthur M.; Ramachandran, B. R.; Glendening, Eric D.
2007-01-01
A report is presented to describe how students can be empowered to construct the full, double minimum inversion potential for ammonia by performing intrinsic reaction coordinate calculations. This work can be associated with the third year physical chemistry lecture laboratory or an upper level course in computational chemistry.
Hormones and Dichotic Listening: Evidence from the Study of Menstrual Cycle Effects
ERIC Educational Resources Information Center
Cowell, Patricia E.; Ledger, William L.; Wadnerkar, Meghana B.; Skilling, Fiona M.; Whiteside, Sandra P.
2011-01-01
This report presents evidence for changes in dichotic listening asymmetries across the menstrual cycle, which replicate studies from our laboratory and others. Increases in the right ear advantage (REA) were present in women at phases of the menstrual cycle associated with higher levels of ovarian hormones. The data also revealed correlations…
2007-08-30
ITRC Interstate Technology Regulatory Council LRL Laboratory reporting level LDPE Low-density polyethylene MDL Minimum detection limit MNA...diameter of the well. Another diffusion membrane sampler design consists of a tubular-shaped bag made of flexible low-density polyethylene ( LDPE ...
The Self-Assembly Properties of a Benzene-1,3,5-tricarboxamide Derivative
ERIC Educational Resources Information Center
Stals, Patrick J. M.; Haveman, Jan F.; Palmans, Anja R. A.; Schenning, Albertus P. H. J.
2009-01-01
A series of experiments involving the synthesis and characterization of a benzene-1,3,5-tricarboxamide derivative and its self-assembly properties are reported. These laboratory experiments combine organic synthesis, self-assembly, and physical characterization and are designed for upper-level undergraduate students to introduce the topic of…
Evaluation of Instructional Systems RUPS and TABA. Final Report.
ERIC Educational Resources Information Center
O'Neill, Phillip M.
An investigation was conducted to determine the extent of dissemination of the Research Utilizing Problem Solving (Rups) and Development of Higher Level Thinking Abilities (TABA) instructional systems developed by the Northwest Regional Laboratory (NWREL), the degree of conformity between the RUPS and TABA systems as developed and as used in the…
DOT National Transportation Integrated Search
2016-12-16
The concept of accessibility has made inroads into planning practice, largely at the system level. That is, accessibility is measured or modeled for current or future regional transportation and land-use scenarios for evaluation or broad policy guida...
Audiovisual Physics Reports: Students' Video Production as a Strategy for the Didactic Laboratory
ERIC Educational Resources Information Center
Pereira, Marcus Vinicius; de Souza Barros, Susana; de Rezende Filho, Luiz Augusto C.; de A. Fauth, Leduc Hermeto
2012-01-01
Constant technological advancement has facilitated access to digital cameras and cell phones. Involving students in a video production project can work as a motivating aspect to make them active and reflective in their learning, intellectually engaged in a recursive process. This project was implemented in high school level physics laboratory…
Swales, Danielle A; Winiarski, Dominika A; Smith, Alicia K; Stowe, Zachary N; Newport, D Jeffrey; Brennan, Patricia A
2018-05-25
Prenatal exposures to higher levels of maternal cortisol and depression have been linked to a variety of adverse physiological, neurological, and behavioral outcomes, such as dysregulated cortisol production, structural and functional differences in limbic areas of the brain, and greater negative emotionality. This study investigated prospective associations between maternal prepartum depression/cortisol levels and offspring emotional reactivity in 163 mother-child pairs. Women were assessed repeatedly during pregnancy, and later participated in a laboratory visit with their preschool-aged children. Mothers self-reported on depressive symptomatology during pregnancy and provided saliva samples for cortisol assay. Offspring emotional reactivity was assessed through multiple measures, including caregiver reports, cortisol response following a stressor, and laboratory observations of behavior. The findings suggest potential prenatal timing effects, with depression and maternal cortisol measured in the first and second trimesters being more strongly associated with child emotional reactivity. Sex was found to moderate associations between maternal prepartum depression/cortisol and child emotional reactivity, with the general pattern reflecting positive associations in girls, and negative associations in boys. © 2018 Wiley Periodicals, Inc.
Blood lipid measurements. Variations and practical utility.
Cooper, G R; Myers, G L; Smith, S J; Schlant, R C
1992-03-25
To describe the magnitude and impact of the major biological and analytical sources of variation in serum lipid and lipoprotein levels on risk of coronary heart disease; to present a way to qualitatively estimate the total intraindividual variation; and to demonstrate how to determine the number of specimens required to estimate, with 95% confidence, the "true" underlying total cholesterol value in the serum of a patient. Representative references on each source of variation were selected from more than 300 reviewed publications, most published within the past 5 years, to document current findings and concepts. Most articles reviewed were in English. Studies on biological sources of variation were selected using the following criteria: representative of published findings, clear statement of either significant or insignificant results, and acquisition of clinical and laboratory data under standardized conditions. Representative results for special populations such as women and children are reported when results differ from those of adult men. References were selected based on acceptable experimental design and use of standardized laboratory lipid measurements. The lipid levels considered representative for a selected source of variation arose from quantitative measurements by a suitably standardized laboratory. Statistical analysis of data was examined to assure reliability. The proposed method of estimating the biological coefficient of variation must be considered to give qualitative results, because only two or three serial specimens are collected in most cases for the estimation. Concern has arisen about the magnitude, impact, and interpretation of preanalytical as well as analytical sources of variation on reported results of lipid measurements of an individual. Preanalytical sources of variation from behavioral, clinical, and sampling sources constitute about 60% of the total variation in a reported lipid measurement of an individual. A technique is presented to allow physicians to qualitatively estimate the intraindividual biological variation of a patient from the results of two or more specimens reported from a standardized laboratory and to determine whether additional specimens are needed to meet the National Cholesterol Education Program recommendation that the intraindividual serum total cholesterol coefficient of variation not exceed 5.0. A National Reference Method Network has been established to help solve analytical problems.
Current use of equations for estimating glomerular filtration rate in Spanish laboratories.
Gràcia-Garcia, Sílvia; Montañés-Bermúdez, Rosario; Morales-García, Luis J; Díez-de Los Ríos, M José; Jiménez-García, Juan Á; Macías-Blanco, Carlos; Martínez-López, Rosalina; Ruiz-Altarejos, Joaquín; Ruiz-Martín, Guadalupe; Sanz-Hernández, Sonia; Ventura-Pedret, Salvador
2012-07-17
In 2006 the Spanish Society of Clinical Biochemistry and Molecular Pathology (SEQC) and the Spanish Society of Nephrology (S.E.N.) developed a consensus document in order to facilitate the diagnosis and monitoring of chronic kidney disease with the incorporation of equations for estimating glomerular filtration rate (eGFR) into laboratory reports. The current national prevalence of eGFR reporting and the degree of adherence to these recommendations among clinical laboratories is unknown. We administered a national survey in 2010-11 to Spanish clinical laboratories. The survey was through e-mail or telephone to laboratories that participated in the SEQC’s Programme for External Quality Assurance, included in the National Hospitals Catalogue 2010, including both primary care and private laboratories. A total of 281 laboratories answered to the survey. Of these, 88.2% reported on the eGFR, with 61.9% reporting on the MDRD equation and 31.6% using the MDRD-IDMS equation. A total of 42.5% of laboratories always reported serum creatinine values, and other variables only when specifically requested. Regarding the way results were presented, 46.2% of laboratories reported the exact numerical value only when the filtration rate was below 60mL/min/1.73m2, while 50.6% reported all values regardless. In 56.3% of the cases reporting eGFR, an interpretive commentary of it was enclosed. Although a high percentage of Spanish laboratories have added eGFR in their reports, this metric is not universally used. Moreover, some aspects, such as the equation used and the correct expression of eGFR results, should be improved.
Francy, D.S.; Jones, A.L.; Myers, Donna N.; Rowe, G.L.; Eberle, Michael; Sarver, K.M.
1998-01-01
The U.S. Geological Survey (USGS), Water Resources Division (WRD), requires that quality-assurance/quality-control (QA/QC) activities be included in any sampling and analysis program. Operational QA/QC procedures address local needs while incorporating national policies. Therefore, specific technical policies were established for all activities associated with water-quality project being done by the Ohio District. The policies described in this report provide Ohio District personnel, cooperating agencies, and others with a reference manual on QA/QC procedures that are followed in collecitng and analyzing water-quality samples and reporting water-quality information in the Ohio District. The project chief, project support staff, District Water-Quality Specialist, and District Laboratory Coordinator are all involved in planning and implementing QA/QC activities at the district level. The District Chief and other district-level managers provide oversight, and the Regional Water-Quality Specialist, Office of Water Quality (USGS headquarters), and the Branch of Quality Systems within the Office of Water Quality create national QA/QC polices and provide assistance to District personnel. In the literature, the quality of all measurement data is expressed in terms of precision, variability, bias, accuracy, completeness, representativeness, and comparability. In the Ohio District, bias and variability will be used to describe quality-control data generated from samples in the field and laboratory. Each project chief must plan for implementation and financing of QA/QC activities necessary to achieve data-quality objectives. At least 15 percent of the total project effort must be directed toward QA/QC activities. Of this total, 5-10 percent will be used for collection and analysis of quality-control samples. This is an absolute minimum, and more may be required based on project objectives. Proper techniques must be followed in the collection and processing of surface-water, ground-water, biological, precipitation, bed-sediment, bedload, suspended-sediment, and solid-phase samples. These techniques are briefly described in this report and are extensively documented. The reference documents listed in this report will be kept by the District librarian and District Water-Quality Specialist and updated regularly so that they are available to all District staff. Proper handling and documentation before, during, and after field activities are essential to ensure the integrity of the sample and to correct erroneous reporting of data results. Field sites are to be properly identified and entered into the data base before field data-collection activities begin. During field activities, field notes are to be completed and sample bottles appropriately labeled a nd stored. After field activities, all paperwork is to be completed promptly and samples transferred to the laboratory within allowable holding times. All equipment used by District personnel for the collection and processing of water-quality samples is to be properly operated, maintained, and calibrated by project personnel. This includes equipment for onsite measurement of water-quality characteristics (temperature, specific conductance, pH, dissolved oxygen, alkalinity, acidity, and turbidity) and equipment and instruments used for biological sampling. The District Water-Quality Specialist and District Laboratory Coordinator are responsible for preventive maintenance and calibration of equipment in the Ohio District laboratory. The USGS National Water Quality Laboratory in Arvada, Colo., is the primary source of analytical services for most project work done by the Ohio District. Analyses done at the Ohio District laboratory are usually those that must be completed within a few hours of sample collection. Contract laboratories or other USGS laboratories are sometimes used instead of the NWQL or the Ohio District laboratory. When a contract laboratory is used, the projec
Utility of plasma free metanephrines in diagnosis of factitious pheochromocytoma.
Chidakel, Aaron R; Pacak, Karel; Eisenhofer, Graeme; Lawrence, Jennifer E; Ayala, Alejandro R
2006-01-01
To report a case of epinephrine-induced factitious pheochromocytoma in a young woman with a past medical history of Conn's syndrome. We present a case report with clinical and laboratory details, review related reports in the literature, and demonstrate the usefulness of plasma free metanephrine levels in facilitating the diagnosis of factitious pheochromocytoma. A 34-year-old woman was admitted to our hospital for confirmation and localization of an occult pheochromocytoma. After thorough investigation, we discovered that the patient was surreptitiously injecting epinephrine in order to induce symptoms and signs consistent with a pheochromocytoma. Analysis of the patient's biochemical profile during and between her catecholaminergic crises revealed plasma epinephrine and free metanephrine levels that would be highly unusual for a patient with a pheochromocytoma. This case illustrates the utility of implementing the ratio of plasma epinephrine to free metanephrine levels in distinguishing factitious from organic pheochromocytoma.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Meimei; Natesan, K.; Chen, Wei-Ying
This report provides an update on the understanding of the effect of sodium exposures on microstructure and tensile properties of Grade 91 (G91) steel in support of the design and operation of G91 components in sodium-cooled fast reactors (SFRs). The report is a Level 3 deliverable in FY17 (M3AT-17AN1602018), under the Work Package AT-17AN160201, “SFR Materials Testing” performed by the Argonne National Laboratory (ANL), as part of the Advanced Reactor Technologies Program.
Oak Ridge National Laboratory Institutional Plan, FY 1995--FY 2000
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1994-11-01
This report discusses the institutional plan for Oak Ridge National Laboratory for the next five years (1995-2000). Included in this report are the: laboratory director`s statement; laboratory mission, vision, and core competencies; laboratory plan; major laboratory initiatives; scientific and technical programs; critical success factors; summaries of other plans; and resource projections.
Six-Inch Shock Tube Characterization
2016-12-09
Change of Address Organizations receiving reports from the U.S. Army Aeromedical Research Laboratory on automatic mailing lists should confirm...92A Figure 2 summarizes the peak levels for shots using 92A Mylar® as a membrane with a linear trend line overlaid on the data, which produced the...peak levels for shots using 500A Mylar® as a membrane with a 6th-order polynomial trend line overlaid on the data, which produced the highest R2 value
NASA Technical Reports Server (NTRS)
Varsi, Giulio
1989-01-01
The problem of the remote control of space operations is addressed by identifying the key technical challenge: the management of contact forces and the principal performance parameters. Three principal classes of devices for remote operation are identified: anthropomorphic exoskeletons, computer aided teleoperators, and supervised telerobots. Their fields of application are described, and areas in which progress has reached the level of system or subsystem laboratory demonstrations are indicated. Key test results, indicating performance at a level useful for design tradeoffs, are reported.
NASA Astrophysics Data System (ADS)
Meade, Karen Marie
The purpose of this study was to identify conceptual and attitudinal effects of inquiry learning in technology-based undergraduate chemistry laboratories. There were 428 participants who were registered in general chemistry laboratory at the University of Iowa in the Spring of 2002. Conceptual and attitudinal pretest and posttest results were quantitative in nature. Qualitative results were collected from questionnaires and focus groups. Quantitative data were analyzed using a repeated measures analysis of variance to identify differences between treatment groups. A high-inquiry treatment group was open-ended and required student decisions regarding data collection, data representation, and interpretation. The low-inquiry treatment involved collaboration and traditional learning strategies. Major findings of this study were: (1) Pretest to posttest conceptual gains were significant for both treatment groups. Low-inquiry students performed significantly better on exploration questions than high-inquiry students. (2) Process skills developed at higher levels for high-inquiry students than low-inquiry students. (3) Positive attitudes decreased significantly for all students from pretest to posttest. More favorable attitudes toward science enjoyment and the ability to do well in science were found for high-inquiry students. More favorable attitudes toward science enjoyment and the ability to do well in science were found for low-inquiry males and high-inquiry females. (4) More favorable attitudes toward the nature of science caused by use of the learning cycle were reported by high-inquiry students. (5) Low-inquiry students reported more favorable attitudes toward technologies in the laboratory than did high-inquiry students. Favorable attitudes toward the use of infrared spectrometers and unfavorable attitudes toward the use of pH meters were reported by both treatment groups. (6) More formal reasoning skills were reported by high-inquiry students. Both groups reported that looking for patterns was a common theme in the laboratories. Hypotheses were reported as rarely used by both treatment groups. These findings are significant because they indicate that inquiry activities positively affect attitudes toward science, gender equality, and contribute to the development of formal reasoning skills and process skills.
Stanley, Brett J; Antonio, Karen
2012-11-01
Several methods exist for the measurement of cyanide levels in treated wastewater,typically requiring preservation of the sample with sodium hydroxide to minimize loss of hydrogen cyanide gas (HCN). Recent reports have shown that cyanide levels may increase with chlorination or preservation. In this study, three flow injection analysis methods involving colorimetric and amperometric detection were compared within one laboratory, as well as across separate laboratories and equipment. Split wastewater samples from eight facilities and three different sampling periods were tested. An interlaboratory confidence interval of 3.5 ppb was calculated compared with the intralaboratory reporting limit of 2 ppb. The results show that free cyanide measurements are not statistically different than total cyanide levels. An artificial increase in cyanide level is observed with all methods for preserved samples relative to nonpreserved samples, with an average increase of 2.3 ppb. The possible loss of cyanide without preservation is shown to be statistically insignificant if properly stored up to 48 hours. The cyanide increase with preservation is further substantiated with the method of standard additions and is not a matrix interference. The increase appears to be correlated with the amount of cyanide observed without preservation, which appears to be greater in those facilities that disinfect their wastewater with chlorine, followed by dechlorination with sodium bisulfite.
Is Social Anhedonia related to Emotional Responsivity and Expressivity? A laboratory study in Women
Leung, Winnie W.; Couture, Shannon M.; Blanchard, Jack J.; Lin, Stephanie; Llerena, Katiah
2010-01-01
Social anhedonia is an important feature of schizophrenia and it is a promising indicator of schizotypy. Although social anhedonia is defined as an affective construct (less pleasure derived from social encounters), little is known about the emotional responsivity and expressivity of individuals with high levels of social anhedonia. After screening a large sample of female undergraduate students (N = 1 085), a cohort of psychometrically identified individuals with high levels of social anhedonia (n = 34) and normally hedonic controls (n = 45) participated in laboratory assessments involving trait affectivity, self-reported dispositional emotional expressiveness, and the expression and experience of emotion in response to neutral, nonaffiliative (i.e., comedy) and affiliative film clips. Results revealed that individuals with high levels of social anhedonia are characterized by lower positive affect, both as a trait and in response to emotionally evocative stimuli, and are less facially expressive, both by their own self-report and in response to film clips. Attenuated positive affect was observed across film stimuli, indicating a general reduction in affective response rather than a specific decrease in responsivity for affiliative stimuli. Future work should continue to investigate whether there is a unique role for social stimuli in the emotional lives of individuals with high levels of social anhedonia or whether these individuals tend to experience anhedonia more broadly regardless of social context. PMID:20620020
Delany, Judy R; Pentella, Michael A; Rodriguez, Joyce A; Shah, Kajari V; Baxley, Karen P; Holmes, David E
2011-04-15
These guidelines for biosafety laboratory competency outline the essential skills, knowledge, and abilities required for working with biologic agents at the three highest biosafety levels (BSLs) (levels 2, 3, and 4). The competencies are tiered to a worker's experience at three levels: entry level, midlevel (experienced), and senior level (supervisory or managerial positions). These guidelines were developed on behalf of CDC and the Association of Public Health Laboratories (APHL) by an expert panel comprising 27 experts representing state and federal public health laboratories, private sector clinical and research laboratories, and academic centers. They were then reviewed by approximately 300 practitioners representing the relevant fields. The guidelines are intended for laboratorians working with hazardous biologic agents, obtained from either samples or specimens that are maintained and manipulated in clinical, environmental, public health, academic, and research laboratories.
Selliah, S S; Cussion, S; MacPherson, K A; Reiner, E J; Toner, D
2001-06-01
Matrix-matched environmental certified reference materials (CRMs) are one of the most useful tools to validate analytical methods, assess analytical laboratory performance and to assist in the resolution of data conflicts between laboratories. This paper describes the development of a lake sediment as a CRM for polychorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (DLPCBs). The presence of DLPCBs in the environment is of increased concern and analytical methods are being developed internationally for monitoring DLPCBs in the environment. This paper also reports the results of an international interlaboratory study involving thirty-five laboratories from seventeen countries, conducted to characterize and validate levels of a sediment reference material for PCDDs, PCDFs and DLPCBs.
Validity of self-reported vitamin D deficiency among midlife Arab women living in Qatar.
Gerber, Linda M; Giambrone, Ashley E; Al-Ali, Hala M; Verjee, Mohamud A
2016-01-01
This study evaluates the level of agreement between self-reported vitamin D deficiency and serum vitamin D measured within the previous calendar year. In a study in which serum 25(OH)D levels were retrieved from electronic health records, 523 women were asked whether they considered themselves to have vitamin D deficiency. Serum vitamin D levels were categorized as vitamin D deficiency if serum 25(OH)D was <20 ng/ml and as insufficiency if <30 ng/ml. The kappa statistic was computed to assess the level of agreement between serum 25(OH)D level and self-report responses. Agreement between self-reported and measured 25(OH)D levels was poor. The kappa statistic was -0.041 when using a cutpoint of <20 ng/ml and -0.008 using the cutpoint of <30 ng/ml. Among women with levels ≥20 ng/ml, 82.4% believed that they were vitamin D deficient, while 13.3% who were below <20 ng/ml did not self-report deficiency. Among women who did not report vitamin D deficiency, 46.3% (37/80) had levels <20 ng/ml while 82.5% (66/80) had levels <30 ng/ml. These findings suggest that, although the prevalence of 25(OH)D <20 and <30 ng/ml was quite high (53.2% and 84.7%, respectively), there was little agreement between measured levels and self-report of vitamin D deficiency. This may be due to belief in this region that low levels of serum vitamin D is widespread. Better communication is needed between healthcare providers and patients regarding transmission of laboratory results. © 2015 Wiley Periodicals, Inc.
Annual Report on the State of the DOE National Laboratories
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2017-01-01
This first Annual Report to Congress on the State of the DOE National Laboratories provides a comprehensive overview of the Lab system, covering S&T programs, management and strategic planning. The Department committed to prepare this report in response to recommendations from the Congressionally mandated Commission to Review the Effectiveness of the National Energy Laboratories (CRENEL) that the Department should better communicate the value that the Laboratories provide to the Nation. We expect that future annual reports will be much more compact, building on the extensive description of the Laboratories and of the governance structures that are part of this firstmore » report.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Virginia L. Finley
The purpose of this report is to provide the U.S. Department of Energy (DOE) and the public with information on the level of radioactive and nonradioactive pollutants (if any) that are added to the environment as a result of the Princeton Plasma Physics Laboratory's (PPPL) operations. The results of the 2001 environmental surveillance and monitoring program for PPPL are presented and discussed. The report also summarizes environmental initiatives, assessments, and programs that were undertaken in 2001. PPPL has engaged in fusion energy research since 1951. The vision of the Laboratory is to create innovations to make fusion power a practicalmore » reality--a clean, alternative energy source. The Year 2001 marked the third year of National Spherical Torus Experiment (NSTX) operations and Tokamak Fusion Test Reactor (TFTR) dismantlement and deconstruction activities. A collaboration among fourteen national laboratories, universities, and research institutions, the NSTX is a major element in the U.S. Fusion Energy Sciences Program. It has been designed to test the physics principles of spherical torus (ST) plasmas. The ST concept could play an important role in the development of smaller, more economical fusion reactors. In 2001, PPPL's radiological environmental monitoring program measured tritium in the air at on- and off-site sampling stations. PPPL is capable of detecting small changes in the ambient levels of tritium by using highly sensitive monitors. The operation of an in-stack monitor located on D-site is a requirement of the National Emission Standard for Hazardous Air Pollutants (NESHAPs) regulations; also included in PPPL's radiological environmental monitoring program, are water monitoring--precipitation, ground-, surface-, and waste-waters. PPPL's radiological monitoring program characterized the ambient, background levels of tritium in the environment and from the D-site stack; the data are presented in this report. Groundwater monitoring continue d under a voluntary agreement with the New Jersey Department of Environmental Protection. PPPL monitored for the presence of nonradiological contaminants, mainly volatile organic compounds (components of degreasing solvents). Monitoring revealed the low levels of volatile organic compounds in an area adjacent to PPPL. In 2001, PPPL was in compliance with its permit limits for surface and sanitary discharges and had no reportable releases. Additionally, as part of DOE's program for the purchase of recycled content and other environmentally preferred products, PPPL has ranked in the excellent category of 80 to 90% of the goal.« less
Digital and multimedia forensics justified: An appraisal on professional policy and legislation
NASA Astrophysics Data System (ADS)
Popejoy, Amy Lynnette
Recent progress in professional policy and legislation at the federal level in the field of forensic science constructs a transformation of new outcomes for future experts. An exploratory and descriptive qualitative methodology was used to critique and examine Digital and Multimedia Science (DMS) as a justified forensic discipline. Chapter I summarizes Recommendations 1, 2, and 10 of the National Academy of Sciences (NAS) Report 2009 regarding disparities and challenges facing the forensic science community. Chapter I also delivers the overall foundation and framework of this thesis, specifically how it relates to DMS. Chapter II expands on Recommendation 1: "The Promotion and Development of Forensic Science," and focuses chronologically on professional policy and legislative advances through 2014. Chapter III addresses Recommendation 2: "The Standardization of Terminology in Reporting and Testimony," and the issues of legal language and terminology, model laboratory reports, and expert testimony concerning DMS case law. Chapter IV analyzes Recommendation 10: "Insufficient Education and Training," identifying legal awareness for the digital and multimedia examiner to understand the role of the expert witness, the attorney, the judge and the admission of forensic science evidence in litigation in our criminal justice system. Finally, Chapter V studies three DME specific laboratories at the Texas state, county, and city level, concentrating on current practice and procedure.
Emery, Helen T.; McElwain, Nancy L.; Groh, Ashley M.; Haydon, Katherine C.; Roisman, Glenn I.
2015-01-01
The present study investigated maternal dispositional empathy and skin conductance level (SCL) reactivity to infant emotional cues as joint predictors of maternal sensitivity. Sixty-four mother-toddler dyads (31 boys) were observed across a series of interaction tasks during a laboratory visit, and maternal sensitivity was coded from approximately 55 minutes of observation per family. In a second, mother-only laboratory visit, maternal SCL reactivity to infant cues was assessed using a cry-laugh audio paradigm. Mothers reported on their dispositional empathy via a questionnaire. As hypothesized, mothers with greater dispositional empathy exhibited more sensitive behavior at low, but not high, levels of SCL reactivity to infant cues. Analyses examining self-reported emotional reactivity to the cry-laugh audio paradigm yielded a similar finding: dispositional empathy was related to greater sensitivity when mothers reported low, but not high, negative emotional reactivity. Results provide support for Dix’s (1991) affective model of parenting that underscores the combined contribution of the parent’s empathic tendencies and his/her own emotional experience in response to child emotions. Specificity of the Empathy × Reactivity interaction is discussed with respect to the context in which reactivity was assessed (infant cry versus laugh) and the type of sensitivity examined (sensitivity to the child’s distress versus non-distress). PMID:24955589
Emery, Helen T; McElwain, Nancy L; Groh, Ashley M; Haydon, Katherine C; Roisman, Glenn I
2014-08-01
The present study investigated maternal dispositional empathy and skin conductance level (SCL) reactivity to infant emotional cues as joint predictors of maternal sensitivity. Sixty-four mother-toddler dyads (31 boys) were observed across a series of interaction tasks during a laboratory visit, and maternal sensitivity was coded from approximately 55 minutes of observation per family. In a second, mother-only laboratory visit, maternal SCL reactivity to infant cues was assessed using a cry-laugh audio paradigm. Mothers reported on their dispositional empathy via a questionnaire. As hypothesized, mothers with greater dispositional empathy exhibited more sensitive behavior at low, but not high, levels of SCL reactivity to infant cues. Analyses examining self-reported emotional reactivity to the cry-laugh audio paradigm yielded a similar finding: Dispositional empathy was related to greater sensitivity when mothers reported low, but not high, negative emotional reactivity. Results provide support for Dix's (1991) affective model of parenting that underscores the combined contribution of the parent's empathic tendencies and his or her own emotional experience in response to child emotions. Specificity of the Empathy × Reactivity interaction is discussed with respect to the context in which reactivity was assessed (infant cry vs. laugh) and the type of sensitivity examined (sensitivity to the child's distress vs. nondistress).
Hawkins, Robert C; Badrick, Tony
2015-08-01
In this study we aimed to compare the reporting unit size used by Australian laboratories for routine chemistry and haematology tests to the unit size used by learned authorities and in standard laboratory textbooks and to the justified unit size based on measurement uncertainty (MU) estimates from quality assurance program data. MU was determined from Royal College of Pathologists of Australasia (RCPA) - Australasian Association of Clinical Biochemists (AACB) and RCPA Haematology Quality Assurance Program survey reports. The reporting unit size implicitly suggested in authoritative textbooks, the RCPA Manual, and the General Serum Chemistry program itself was noted. We also used published data on Australian laboratory practices.The best performing laboratories could justify their chemistry unit size for 55% of analytes while comparable figures for the 50% and 90% laboratories were 14% and 8%, respectively. Reporting unit size was justifiable for all laboratories for red cell count, >50% for haemoglobin but only the top 10% for haematocrit. Few, if any, could justify their mean cell volume (MCV) and mean cell haemoglobin concentration (MCHC) reporting unit sizes.The reporting unit size used by many laboratories is not justified by present analytical performance. Using MU estimates to determine the reporting interval for quantitative laboratory results ensures reporting practices match local analytical performance and recognises the inherent error of the measurement process.
Components of laboratory accreditation.
Royal, P D
1995-12-01
Accreditation or certification is a recognition given to an operation or product that has been evaluated against a standard; be it regulatory or voluntary. The purpose of accreditation is to provide the consumer with a level of confidence in the quality of operation (process) and the product of an organization. Environmental Protection Agency/OCM has proposed the development of an accreditation program under National Environmental Laboratory Accreditation Program for Good Laboratory Practice (GLP) laboratories as a supplement to the current program. This proposal was the result of the Inspector General Office reports that identified weaknesses in the current operation. Several accreditation programs can be evaluated and common components identified when proposing a structure for accrediting a GLP system. An understanding of these components is useful in building that structure. Internationally accepted accreditation programs provide a template for building a U.S. GLP accreditation program. This presentation will discuss the traditional structure of accreditation as presented in the Organization of Economic Cooperative Development/GLP program, ISO-9000 Accreditation and ISO/IEC Guide 25 Standard, and the Canadian Association for Environmental Analytical Laboratories, which has a biological component. Most accreditation programs are managed by a recognized third party, either privately or with government oversight. Common components often include a formal review of required credentials to evaluate organizational structure, a site visit to evaluate the facility, and a performance evaluation to assess technical competence. Laboratory performance is measured against written standards and scored. A formal report is then sent to the laboratory indicating accreditation status. Usually, there is a scheduled reevaluation built into the program. Fee structures vary considerably and will need to be examined closely when building a GLP program.
Policies, Organisation and Procedures in the Technical Cooperation Program
2009-03-10
it is normal practise for each Group to request an annual report from their TPs and AGs. The aims of such a report are to allow the Group to better...and validation of such models and, where possible, conduct collaborative laboratory and/or field experiments to fill data gaps. Provide expert...recommendation from a flag level official or a laboratory director who understands and appreciates the technical and operational significance
A laboratory information management system for the analysis of tritium (3H) in environmental waters.
Belachew, Dagnachew Legesse; Terzer-Wassmuth, Stefan; Wassenaar, Leonard I; Klaus, Philipp M; Copia, Lorenzo; Araguás, Luis J Araguás; Aggarwal, Pradeep
2018-07-01
Accurate and precise measurements of low levels of tritium ( 3 H) in environmental waters are difficult to attain due to complex steps of sample preparation, electrolytic enrichment, liquid scintillation decay counting, and extensive data processing. We present a Microsoft Access™ relational database application, TRIMS (Tritium Information Management System) to assist with sample and data processing of tritium analysis by managing the processes from sample registration and analysis to reporting and archiving. A complete uncertainty propagation algorithm ensures tritium results are reported with robust uncertainty metrics. TRIMS will help to increase laboratory productivity and improve the accuracy and precision of 3 H assays. The software supports several enrichment protocols and LSC counter types. TRIMS is available for download at no cost from the IAEA at www.iaea.org/water. Copyright © 2018 Elsevier Ltd. All rights reserved.
A noise control package for vibrating screens1),2)
Lowe, M. Jenae; Yantek, David S.; Yang, Junyi; Schuster, Kevin C.; Mechling, Jessie J.
2015-01-01
Hearing loss was the second-most common illness reported to the Mine Safety and Health Administration (MSHA) in 2009. Furthermore, between 2000 and 2010, 30% of all noise-related injury complaints reported to MSHA were for coal preparation plant employees. Previous National Institute for Occupational Safety and Health (NIOSH) studies have shown that vibrating screens are key noise sources to address in order to reduce coal preparation plant noise. In response, NIOSH researchers have developed a suite of noise controls for vibrating screens consisting of constrained layer damping (CLD) treatments, a tuned mechanism suspension, an acoustic enclosure, and spring inserts. Laboratory testing demonstrates that this noise control suite reduces the A-weighted sound power level of the vibrating screen by 6 dB. To provide a comparison to laboratory results and prove durability, field testing of two noise controls was performed on a vibrating screen in a working coal preparation plant. The spring inserts and CLD treatments were selected due to their ease of installation and practicability. Field testing of these controls yielded reductions that were comparable to laboratory results. PMID:26257468
Droplet Microfluidic and Magnetic Particles Platform for Cancer Typing.
Ferraro, Davide; Champ, Jérôme; Teste, Bruno; Serra, M; Malaquin, Laurent; Descroix, Stéphanie; de Cremoux, Patricia; Viovy, Jean-Louis
2017-01-01
Analyses of nucleic acids are routinely performed in hospital laboratories to detect gene alterations for cancer diagnosis and treatment decision. Among the different possible investigations, mRNA analysis provides information on abnormal levels of genes expression. Standard laboratory methods are still not adapted to the isolation and quantitation of low mRNA amounts and new techniques needs to be developed in particular for rare subsets analysis. By reducing the volume involved, time process, and the contamination risks, droplet microfluidics provide numerous advantages to perform analysis down to the single cell level.We report on a droplet microfluidic platform based on the manipulation of magnetic particles that allows the clinical analysis of tumor tissues. In particular, it allows the extraction of mRNA from the total-RNA sample, Reverse Transcription, and cDNA amplification, all in droplets.
Hepatotoxicity induced by methimazole in a previously healthy patient.
Gallelli, Luca; Staltari, Orietta; Palleria, Caterina; De Sarro, Giovambattista; Ferraro, Maria
2009-09-01
We report a case of hepatotoxicity induced by methimazole treatment in a patient affected by hyperthyroidism. A 54-year-old man, presented to our observation for palpitations, excessive sweating, weakness, heat intolerance and weight loss. On physical examination, his blood pressure was 140/90 mmHg and heart beat was 100/min regular. He had mild tremors and left exophthalmos. Laboratory test revealed a significant increase in serum thyroid hormone levels with a decrease in thyroid stimulating hormone levels. A diagnosis of hyperthyroidism was made and he began treatment with methimazole (30 mg/day). Fourteen days later, he returned for the development of scleral icterus, followed by dark urine, and abdominal pain in the right upper quadrant. Laboratory examinations and liver biopsy performed a diagnosis of cholestatic hepatitis, secondary to methimazole usage. Methimazole was promptly withdrawn and cholestyramine, ursodeoxycholic acid, and chlorpheniramine were given. After five days, abdominal pain resolved and laboratory parameters returned to normal. Naranjo probability scale indicated a probable relationship between hepatotoxicity and methimazole therapy. In conclusion physicians should be aware the risk of hepatotoxicity related with methimazole.
A Computerized Data-Capture System for Animal Biosafety Level 4 Laboratories
Bente, Dennis A; Friesen, Jeremy; White, Kyle; Koll, Jordan; Kobinger, Gary P
2011-01-01
The restrictive nature of an Animal Biosafety Level 4 (ABSL4) laboratory complicates even simple clinical evaluation including data capture. Typically, clinical data are recorded on paper during procedures, faxed out of the ABSL4, and subsequently manually entered into a computer. This system has many disadvantages including transcriptional errors. Here, we describe the development of a highly customizable, tablet-PC-based computerized data-capture system, allowing reliable collection of observational and clinical data from experimental animals in a restrictive biocontainment setting. A multidisciplinary team with skills in containment laboratory animal science, database design, and software engineering collaborated on the development of this system. The goals were to design an easy-to-use and flexible user interface on a touch-screen tablet PC with user-supportable processes for recovery, full auditing capabilities, and cost effectiveness. The system simplifies data capture, reduces the necessary time in an ABSL4 environment, offers timely reporting and review of data, facilitates statistical analysis, reduces potential of erroneous data entry, improves quality assurance of animal care, and advances the use and refinement of humane endpoints. PMID:22330712
Low Cost Space Experiments. Study Report
1991-12-06
Air Force Phillips Laboratory with Johns Hopkins University Applied Physics Laboratory . The goals of ALTAIR...Cs<- &l. LOW COST SPACE EXPERIMENTS STUDY REPORT 6 December 1991 19980302 059 Phillips Laboratory /SXL Kirtland AFB, NM 87117-6008 TVPTT" OTT...Report Corporate Author or Publisher: Phillips Laboratory /SXL, Kirtland AFB,NM 87117-6008 Publication Date: Dec 06, 1991 Pages: 176 Comments
Shokoples, Sandra; Mukhi, Shamir N; Scott, Allison N; Yanow, Stephanie K
2013-06-01
In clinical laboratories, diagnosis of imported malaria is commonly performed by microscopy. However, the volume of specimens is generally low and maintaining proficiency in reading blood smears, particularly at the species level, is challenging in this setting. To address this problem, the Provincial Laboratory for Public Health (ProvLab) in Alberta, Canada, implemented real-time PCR for routine confirmation of all smear-positive samples in the province. Here we report our experience over a 4-year period (2008 to 2012) with this new diagnostic algorithm. While detection of Plasmodium falciparum by microscopy alone was accurate, real-time PCR served as an important adjunct to microscopy for the identification of non-falciparum species. In 18% of cases, the result was reported as non-falciparum or the species could not be identified by microscopy alone, and in all cases, the species was resolved by real-time PCR. In another 4% of cases, the species was misidentified by microscopy. To enhance surveillance for malaria, we integrated our demographic, clinical, and laboratory data into a new system developed by the Canadian Network for Public Health Intelligence, called the Malaria System for Online Surveillance (SOS). Using this application, we characterized our patient populations and travel history to identify risk factors associated with malaria infection abroad.
Mathur, Vani A; Kiley, Kasey B; Haywood, Carlton; Bediako, Shawn M; Lanzkron, Sophie; Carroll, C Patrick; Buenaver, Luis F; Pejsa, Megan; Edwards, Robert R; Haythornthwaite, Jennifer A; Campbell, Claudia M
2016-12-01
People living with sickle cell disease (SCD) experience severe episodic and chronic pain and frequently report poor interpersonal treatment within health-care settings. In this particularly relevant context, we examined the relationship between perceived discrimination and both clinical and laboratory pain. Seventy-one individuals with SCD provided self-reports of experiences with discrimination in health-care settings and clinical pain severity, and completed a psychophysical pain testing battery in the laboratory. Discrimination in health-care settings was correlated with greater clinical pain severity and enhanced sensitivity to multiple laboratory-induced pain measures, as well as stress, depression, and sleep. After controlling for relevant covariates, discrimination remained a significant predictor of mechanical temporal summation (a marker of central pain facilitation), but not clinical pain severity or suprathreshold heat pain response. Furthermore, a significant interaction between experience with discrimination and clinical pain severity was associated with mechanical temporal summation; increased experience with discrimination was associated with an increased correlation between clinical pain severity and temporal summation of pain. Perceived discrimination within health-care settings was associated with pain facilitation. These findings suggest that discrimination may be related to increased central sensitization among SCD patients, and more broadly that health-care social environments may interact with pain pathophysiology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
French, T
The Laboratory Director is pleased to have the opportunity to present the 2008 Laboratory Directed Research and Development (LDRD) annual report. This is my first opportunity to do so, and only the second such report that has been issued. As will be obvious, SRNL has built upon the excellent start that was made with the LDRD program last year, and researchers have broken new ground in some important areas. In reviewing the output of this program this year, it is clear that the researchers implemented their ideas with creativity, skill and enthusiasm. It is gratifying to see this level ofmore » participation, because the LDRD program remains a key part of meeting SRNL's and DOE's strategic goals, and helps lay a solid scientific foundation for SRNL as the premier applied science laboratory. I also believe that the LDRD program's results this year have demonstrated SRNL's value as the EM Corporate Laboratory, having advanced knowledge in a spectrum of areas, including reduction of the technical risks of cleanup, separations science, packaging and transportation of nuclear materials, and many others. The research in support of Energy Security and National and Homeland Security has been no less notable. SRNL' s researchers have shown again that the nascent LDRD program is a sound investment for DOE that will pay off handsomely for the nation as time goes on.« less
1984-07-01
HISTORIC PROPERTIES REPORT HARRY DIAMOND LABORATORIES, MARYLAND ,’ / .’- AND SATELLITE INSTALLATIONS ~WOODBRIDGE RESEARCH FACILITY, VIRGINIA AND ,00... report . METHODOLOGY 1. Documentary Research Harry Diamond Laboratories (HDL) and its two satellite facilities at Woodbridge and Blossom Point are...drawings, and written history. Interagency Archeological Services and U.S. Army, Harry Diamond Laboratories. 106 Case Report and Mitigation Plan: Ballast
Flight Testing Under Extreme Climatic Conditions
1988-09-01
30 Categorizing Hazards and Risk Levels .. ......... 31 CLIMATIC LABORATORIES ..... .............. 33 UNITED KINGDOM ENVIRONMENTAL...FACILITY .. ........ 33 MCKINLEY CIMATIC LABORATORY .... ............ 34 Climatic Laboratory Description ... ........... 35 Climatic Laboratory...Profile 10 3 Risk Level Chart .... ............. . 32 4 Plan View of Climatic Laboratory Main Chamber 36 5 Relative Humidity vs Ambient Air Temperature for
Safety in the Chemical Laboratory: Procedures for Laboratory Destruction of Chemicals.
ERIC Educational Resources Information Center
McKusick, Blaine C.
1984-01-01
Discusses a National Research Council report which summarizes what laboratories need to know about Environmental Protection Agency and Department of Transportation regulations that apply to laboratory waste. The report provides guidelines for establishing and operating waste management systems for laboratories and gives specific advice on waste…
Microarray labeling extension values: laboratory signatures for Affymetrix GeneChips
Lee, Yun-Shien; Chen, Chun-Houh; Tsai, Chi-Neu; Tsai, Chia-Lung; Chao, Angel; Wang, Tzu-Hao
2009-01-01
Interlaboratory comparison of microarray data, even when using the same platform, imposes several challenges to scientists. RNA quality, RNA labeling efficiency, hybridization procedures and data-mining tools can all contribute variations in each laboratory. In Affymetrix GeneChips, about 11–20 different 25-mer oligonucleotides are used to measure the level of each transcript. Here, we report that ‘labeling extension values (LEVs)’, which are correlation coefficients between probe intensities and probe positions, are highly correlated with the gene expression levels (GEVs) on eukayotic Affymetrix microarray data. By analyzing LEVs and GEVs in the publicly available 2414 cel files of 20 Affymetrix microarray types covering 13 species, we found that correlations between LEVs and GEVs only exist in eukaryotic RNAs, but not in prokaryotic ones. Surprisingly, Affymetrix results of the same specimens that were analyzed in different laboratories could be clearly differentiated only by LEVs, leading to the identification of ‘laboratory signatures’. In the examined dataset, GSE10797, filtering out high-LEV genes did not compromise the discovery of biological processes that are constructed by differentially expressed genes. In conclusion, LEVs provide a new filtering parameter for microarray analysis of gene expression and it may improve the inter- and intralaboratory comparability of Affymetrix GeneChips data. PMID:19295132
Childhood Lead Exposure from Battery Recycling in Vietnam
Van Tung, Lo; Wallace, Ryan M.; Havens, Deborah J.; Karr, Catherine J.; Bich Diep, Nguyen; Croteau, Gerry A.; Beaudet, Nancy J.; Duy Bao, Nguyen
2015-01-01
Background. Battery recycling facilities in developing countries can cause community lead exposure. Objective. To evaluate child lead exposure in a Vietnam battery recycling craft village after efforts to shift home-based recycling outside the village. Methods. This cross-sectional study evaluated 109 children in Dong Mai village, using blood lead level (BLL) measurement, parent interview, and household observation. Blood samples were analyzed with a LeadCare II field instrument; highest BLLs (≥45 μg/dL) were retested by laboratory analysis. Surface and soil lead were measured at 11 households and a school with X-ray fluorescence analyzer. Results. All children had high BLLs; 28% had BLL ≥45 μg/dL. Younger age, family recycling, and outside brick surfaces were associated with higher BLL. Surface and soil lead levels were high at all tested homes, even with no recycling history. Laboratory BLLs were lower than LeadCare BLLs, in 24 retested children. Discussion. In spite of improvements, lead exposure was still substantial and probably associated with continued home-based recycling, legacy contamination, and workplace take-home exposure pathways. There is a need for effective strategies to manage lead exposure from battery recycling in craft villages. These reported BLL values should be interpreted cautiously, although the observed field-laboratory discordance may reflect bias in laboratory results. PMID:26587532
Childhood Lead Exposure from Battery Recycling in Vietnam.
Daniell, William E; Van Tung, Lo; Wallace, Ryan M; Havens, Deborah J; Karr, Catherine J; Bich Diep, Nguyen; Croteau, Gerry A; Beaudet, Nancy J; Duy Bao, Nguyen
2015-01-01
Battery recycling facilities in developing countries can cause community lead exposure. To evaluate child lead exposure in a Vietnam battery recycling craft village after efforts to shift home-based recycling outside the village. This cross-sectional study evaluated 109 children in Dong Mai village, using blood lead level (BLL) measurement, parent interview, and household observation. Blood samples were analyzed with a LeadCare II field instrument; highest BLLs (≥45 μg/dL) were retested by laboratory analysis. Surface and soil lead were measured at 11 households and a school with X-ray fluorescence analyzer. All children had high BLLs; 28% had BLL ≥45 μg/dL. Younger age, family recycling, and outside brick surfaces were associated with higher BLL. Surface and soil lead levels were high at all tested homes, even with no recycling history. Laboratory BLLs were lower than LeadCare BLLs, in 24 retested children. In spite of improvements, lead exposure was still substantial and probably associated with continued home-based recycling, legacy contamination, and workplace take-home exposure pathways. There is a need for effective strategies to manage lead exposure from battery recycling in craft villages. These reported BLL values should be interpreted cautiously, although the observed field-laboratory discordance may reflect bias in laboratory results.
Fram, Miranda S.; Olsen, Lisa D.; Belitz, Kenneth
2012-01-01
Volatile organic compounds (VOCs) were analyzed in quality-control samples collected for the California Groundwater Ambient Monitoring and Assessment (GAMA) Program Priority Basin Project. From May 2004 through September 2010, a total of 2,026 groundwater samples, 211 field blanks, and 109 source-solution blanks were collected and analyzed for concentrations of 85 VOCs. Results from analyses of these field and source-solution blanks and of 2,411 laboratory instrument blanks during the same time period were used to assess the quality of data for the 2,026 groundwater samples. Eighteen VOCs were detected in field blanks or source-solution blanks: acetone, benzene, bromodichloromethane, 2-butanone, carbon disulfide, chloroform, 1,1-dichloroethene, dichloromethane, ethylbenzene, tetrachloroethene, styrene, tetrahydrofuran, toluene, trichloroethene, trichlorofluoromethane, 1,2,4-trimethylbenzene, m- and p-xylenes, and o-xylene. The objective of the evaluation of the VOC-blank data was to determine if study reporting levels (SRLs) were needed for any of the VOCs detected in blanks to ensure the quality of the data from groundwater samples. An SRL is equivalent to a raised reporting level that is used in place of the reporting level used by the analyzing laboratory [long‑term method detection level (LT-MDL) or laboratory reporting level (LRL)] to reduce the probability of reporting false-positive detections. Evaluation of VOC-blank data was done in three stages: (1) identification of a set of representative quality‑control field blanks (QCFBs) to be used for calculation of SRLs and identification of VOCs amenable to the SRL approach, (2) evaluation of potential sources of contamination to blanks and groundwater samples by VOCs detected in field blanks, and (3) selection of appropriate SRLs from among four potential SRLs for VOCs detected in field blanks and application of those SRLs to the groundwater data. An important conclusion from this study is that to ensure the quality of the data from groundwater samples, it was necessary to apply different methods of determining SRLs from field blank data to different VOCs, rather than use the same method for all VOCs. Four potential SRL values were defined by using three approaches: two values were defined by using a binomial probability method based on one-sided, nonparametric upper confidence limits, one was defined as equal to the maximum concentration detected in the field blanks, and one was defined as equal to the maximum laboratory method detection level used during the period when samples were collected for the project. The differences in detection frequencies and concentrations among different types of blanks (laboratory instrument blanks, source-solution blanks, and field blanks collected with three different sampling equipment configurations) and groundwater samples were used to infer the sources and mechanisms of contamination for each VOC detection in field blanks. Other chemical data for the groundwater samples (oxidation-reduction state, co-occurrence of VOCs, groundwater age) and ancillary information about the well sites (land use, presence of known sources of contamination) were used to evaluate whether the patterns of detections of VOCs in groundwater samples before and after application of potential SRLs were plausible. On this basis, the appropriate SRL was selected for each VOC that was determined to require an SRL. The SRLs for ethylbenzene [0.06 microgram per liter (μg/L)], m- and p-xylenes (0.33 μg/L), o-xylene (0.12 μg/L), toluene (0.69 μg/L), and 1,2,4-trimethylbenzene (0.56 μg/L) corresponded to the highest concentrations detected in the QCFBs and were selected because they resulted in the most censoring of groundwater data. Comparisons of hydrocarbon ratios in groundwater samples and blanks and comparisons between detection frequencies of the five hydrocarbons in groundwater samples and different types of blanks suggested three dominant sources of contamination that affected groundwater samples and blanks: (1) ethylbenzene, m- and p-xylenes, o-xylene, and toluene from fuel or exhaust components sorbed onto sampling lines, (2) toluene from vials and the source blank water, and (3) 1,2,4-trimethylbenzene from materials used for collection of samples for radon-222 analysis.
Komvilaisak, Patcharee; Wisanuyotin, Suwannee; Jettrisuparb, Arunee; Wiangnon, Surapon
2017-11-01
Lupus anticoagulant, also known as lupus antibody, is generally associated with thrombosis rather than bleeding events. Lupus anticoagulant-hypoprothrombinemia syndrome in children is rather rare but can lead to mild to life-threatening bleeding. Here, we report 3 cases of lupus anticoagulant-hypoprothrombinemia syndrome associated with systemic lupus erythematosus. They initially presented with mucocutaneous bleedings, and subsequently developed other symptoms fulfilling the laboratory criteria for systemic lupus erythematosus. Case 2 and 3 had significant epistaxis and intracerebral hemorrhage responded to systemic corticosteroid along with fresh frozen plasma. Three cases demonstrated acquired hypoprothrombinemia with no correction of mixing studies. Case 1 had low factor X level, which has never been reported previously. In all 3 cases, their coagulogram returned to normal level after corticosteroid treatment.
Awareness and Knowledge of Ergonomics Among Medical Laboratory Scientists in Nigeria.
Oladeinde, B H; Ekejindu, I M; Omoregie, R; Aguh, O D
2015-01-01
Ergonomics awareness helps in its right application and contributes significantly to general wellbeing and safety of worker at workplace. This cross-sectional descriptive study aimed at assessing the level of awareness and knowledge of the science of ergonomics among Medical Laboratory Scientists in Benin City, Nigeria. A total of 106 medical laboratory scientists comprising 64 and 42 in public and private laboratories, respectively, were recruited for this study using systematic random sampling technique. Data were obtained from the study participants using a questionnaire and subsequently analyzed with the statistical software INSTAT(®). Out of 106 study participants, 27 (25.5%) were reported to have heard of the term ergonomics. Awareness was significantly associated with gender (male vs. female: 38.5% [15/39] vs. 17.9% [12/67]; odds ratio = 2.9; 95% confidence interval = 1.2, 7.1;P = 0.02). Awareness of ergonomics was not significantly affected by affiliation (P = 0.18), area of specialization (P = 0.78), post-qualification experience (P = 0.43), and educational qualification (P = 0.23) of the study participants. Irrespective of the affiliation of the participant, only 6 of 27 (22.2%) participants who were aware of ergonomics knew at least a benefit of right application of ergonomics in the laboratory. Knowledge of risk factors for the development of musculoskeletal disorders was reported by 8 of 27 (29.6%) persons who claimed to be aware of ergonomics. Awareness of ergonomics and knowledge of gains of its right application was poor among the study participants. Regular ergonomic education of medical laboratory scientists in Nigeria is advocated.
NASA Astrophysics Data System (ADS)
Gupta, Tanya
Recent initiatives in the laboratory curriculum have encouraged an inquiry-based approach to learning and teaching in the laboratory. It has been argued that laboratory instruction should not just be hands-on, but it should portray the essence of inquiry through the process of experiential learning and reflective engagement in collaboration with peers and in facilitation by the instructor. A student-centered active learning approach may be an effective way to enhance student understanding of concepts in the laboratory. The dissertation research work explores the impact of laboratory instruction and its relevance for college-level chemistry. Each chapter is different from the preceding chapter in terms of the purpose of the study and the research questions asked. However, the overarching idea is to address the importance of guided-inquiry based laboratory instruction in chemistry and its relevance in helping students to make connections with the chemistry content and in imparting skills to students. Such skills include problem solving, collaborative group work and critical thinking. The first research study (Chapter 2) concerns the impact of first year co-requisite general chemistry laboratory instruction on the problem-solving skills of students. The second research study (Chapter 3) examines the impact of implementing student roles also known as Student-Led Instructor Facilitated Guided-Inquiry based Laboratories, SLIFGIL) by modifying the Science Writing Heuristic approach of laboratory instruction. In the third research study (Chapter 4), critical thinking skills of first semester general chemistry laboratory students were compared to advanced (third or fourth year) chemistry laboratory students based on the analysis of their laboratory reports.
Hot flashes and midlife symptoms in relation to levels of salivary cortisol.
Gerber, Linda M; Sievert, Lynnette L; Schwartz, Joseph E
2017-02-01
This study examined the relationship between salivary cortisol levels and hot flashes during midlife. Previous studies have shown that cortisol levels increase with hot flashes in the laboratory, and higher cortisol levels have been associated with more severe hot flashes. Salivary cortisol levels were also examined in relation to total number of midlife symptoms. Women aged 40-60 years (n=109) reported the presence or absence of 23 symptoms, including hot flashes, during the previous 2 weeks. Salivary samples were collected at waking, 30min after waking, 1h before bedtime, and at bedtime. The cortisol awakening response (CAR), cortisol daily decline (CDD), log transformed salivary cortisol levels at each time point, and mean cortisol levels were compared by hot flash report using t-tests. Logistic regression analyses were performed to assess the association between each cortisol measure and the presence or absence of hot flashes, after controlling for potential covariates. Salivary cortisol levels were not significantly associated with hot flashes or sum of symptoms. Hot flash report did not differentiate women who had a positive CAR from those who did not, or women who showed strong CDD from those who did not. Symptomatic women - defined by hot flash report or symptom total - were not found to have higher salivary cortisol levels. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Marinucci, F; Medina-Moreno, S; Paterniti, A D; Wattleworth, M; Redfield, R R
2011-05-01
Improving access to CD4 testing in resource-limited settings can be achieved through both centralized and decentralized testing networks. Decentralized testing models are more suitable for countries where the HIV epidemic affects a large portion of rural populations. Timely access to accurate CD4 results is crucial at the primary level of the health system. For the past 7 years, the Institute of Human Virology of the University of Maryland School of Medicine has implemented a flexible and sustainable three-phase model: (1) site assessment and improvement, (2) appropriate technology selection with capacity building through practical training and laboratory mentoring, and (3) quality management system strengthening and monitoring, to support accessibility to reliable CD4 counting at the point of service. CD4 testing capacity was established in 122 of 229 (53%) laboratories supported in Nigeria, Uganda, Kenya, Zambia, Tanzania, and Rwanda. Among those in rural settings, 46% (69/151) had CD4 testing available at site level, with a functioning flow cytometer installed at 28% (8/29) and 50% (61/122) of level 1 and level 2 sites, respectively. To strengthen local capacity, a total of 1,152 laboratory technicians were trained through 188 training sessions provided both on-site and at central locations. The overall quality of CD4 total testing procedure was assessed at 76% (92/121) of the laboratories, with 25% (23/92), 34% (31/92), and 33% (30/92) of them reporting excellent, good, and satisfactory performance. Balancing country-specific factors with the location of the clinic, number of patients, and the expected workload, was crucial in adapting this flexible model for decentralizing CD4 testing. The close collaboration with local governments and private vendors was key to successfully expanding access to CD4 testing within the framework of HIV care and treatment programs and for the sustainability of medical laboratories in resource-limited settings. Copyright © 2011 International Society for Advancement of Cytometry.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1982-09-01
This bibliography lists publications (831 abstracts) from the Pacific Northwest Laboratory's Department of Energy sponsored research and development programs from January 1978 through July of 1982. The abstracts are grouped in subject categories, as shown in the table of contents. Entries in the subject index also facilitate access by subject, e.g., High-Level Radioactive Wastes. Three indexes, each preceded by a brief description, are provided: personal author, subject, and report number. Cited are research reports, journal articles, books, patents, theses, and conference papers. Excluded are technical progress reports. Since 1978 the Nuclear Waste Management Quarterly Progress Report has been published undermore » the series number PNL-3000. Beginning in 1982, this publication has been issued semiannually, under the series number PNL-4250. This bibliography is the successor to two others, BNWL-2201 (covering the years 1965-1976) and PNL-4050 (1975-1978). It is intended to provide a useful reference to literature in waste management written or compiled by PNL staff.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lewis, Mike
This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (WRU-I-0160-01, formerly LA 000160 01), for the wastewater reuse site at the Idaho National Laboratory Site’s Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond from November 1, 2013 through October 31, 2014. The report contains the following information; Facility and system description; Permit required effluent monitoring data and loading rates; Groundwater monitoring data; Status of special compliance conditions; Noncompliance issues; and Discussion of the facility’s environmental impacts During the 2014 reporting year, an estimated 10.11 million gallons of wastewater were discharged tomore » the Industrial Waste Ditch and Pond which is well below the permit limit of 17 million gallons per year. The concentrations of all permit-required analytes in the samples from the down gradient monitoring wells were below the applicable Idaho Department of Environmental Quality’s groundwater quality standard levels.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mike Lewis
This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (WRU-I-0160-01, formerly LA 000160 01), for the wastewater reuse site at the Idaho National Laboratory Site’s Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond from November 1, 2012 through October 31, 2013. The report contains the following information: • Facility and system description • Permit required effluent monitoring data and loading rates • Groundwater monitoring data • Status of special compliance conditions • Discussion of the facility’s environmental impacts During the 2013 reporting year, an estimated 9.64 million gallons of wastewater weremore » discharged to the Industrial Waste Ditch and Pond which is well below the permit limit of 17 million gallons per year. The concentrations of all permit-required analytes in the samples from the down gradient monitoring wells were below the applicable Idaho Department of Environmental Quality’s groundwater quality standard levels.« less
The Performance Effects of an Ability-Based Approach to Goal Assignment
ERIC Educational Resources Information Center
Jeffrey, Scott A.; Schulz, Axel; Webb, Alan
2012-01-01
Some organizations have begun to target their goal-setting method more closely to the ability levels of their employees. In this article, we report the results of a laboratory study of 138 undergraduate students, which shows that these "ability-based" goals are more effective at improving performance than a "one goal for all"…
Unfulfilled Promise: The Dimensions and Characteristics of Philadelphia's Dropout Crisis, 2000-2005
ERIC Educational Resources Information Center
Neild, Ruth Curran; Balfanz, Robert
2006-01-01
This report uses a unique set of data obtained from the Kids Integrated Data System (KIDS), which is housed at the University of Pennsylvania's Cartographic Modeling Laboratory. The KIDS system merges individual-level data on young people from the School District of Philadelphia and the city's social service agencies, including the Department of…
ERIC Educational Resources Information Center
Bugarcic, A.; Zimbardi, K.; Macaranas, J.; Thorn, P.
2012-01-01
Student-centered education involving research experiences or inquiry have been shown to help undergraduate students understand, and become excited about, the process of scientific investigation. These benefits are particularly important for students in the early stages of their degree (Report and Kenny,…
A Model System for the Study of Gene Expression in the Undergraduate Laboratory
ERIC Educational Resources Information Center
Hargadon, Kristian M.
2016-01-01
The flow of genetic information from DNA to RNA to protein, otherwise known as the "central dogma" of biology, is one of the most basic and overarching concepts in the biological sciences. Nevertheless, numerous studies have reported student misconceptions at the undergraduate level of this fundamental process of gene expression. This…
Design, Fabrication, and Characterization of a Microelectromechanical Directional Microphone
2011-06-01
7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES...Figure 5.2 SOIC packaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Figure 5.3 Laboratory setup...Mean Squared SOC System-On-Chip SOIC Small Outline Integrated Circuit SOIMUMPS Silicon-On-Insulator Multi-User MEMS Process SPL Sound Pressure Level
Research and applications: Artificial intelligence
NASA Technical Reports Server (NTRS)
Raphael, B.; Duda, R. O.; Fikes, R. E.; Hart, P. E.; Nilsson, N. J.; Thorndyke, P. W.; Wilber, B. M.
1971-01-01
Research in the field of artificial intelligence is discussed. The focus of recent work has been the design, implementation, and integration of a completely new system for the control of a robot that plans, learns, and carries out tasks autonomously in a real laboratory environment. The computer implementation of low-level and intermediate-level actions; routines for automated vision; and the planning, generalization, and execution mechanisms are reported. A scenario that demonstrates the approximate capabilities of the current version of the entire robot system is presented.
Hypercalcemia with renal failure.
Bhavani, Nisha; Praveen, Valiyaparambil Pavithran; Jayakumar, Rohinivilasam Vasukutty; Nair, Vasantha; Muraleedharan, Mangath; Kuma, Harish; Unnikrishnan, Ambika Gopalakrishnan; Menon, Vadayath Usha
2012-06-01
We report a cse of nephrocalcinosis with renal failure which on evaluation was found to have hypercalcemia. Further investigations showed an inappropriately normal intact parathormone (iPTH) and 1,25 dihydroxy-vitamin D level in the setting of renal failure. Probing for a cause of non-PTH mediated hypercalcemia led to the diagnosis of sarcoidosis. Treatment with glucocorticoids could partially reverse the renal failure and control the hypercalcemia. This case illustrates the importance of careful interpretation of laboratory parameters especially levels of iPTH and vitamin D metabolites in renal failure.
Hydrogeochemical and stream sediment reconnaissance basic data for Cheyenne Quadrangle, Wyoming
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1981-07-31
Field and laboratory data are presented for 884 water samples and 598 sediment samples from the Cheyenne Quadrangle, Wyoming. Uranium values have been reported by Los Alamos National Laboratory in Report GJBX-106(78). The samples were collected by Los Alamos National Laboratory; laboratory analysis and data reporting were performed by the Uranium Resource Evaluation Project at Oak Ridge, Tennessee.
Evaluating surveillance indicators supporting the Global Polio Eradication Initiative, 2011-2012.
2013-04-12
The Global Polio Eradication Initiative (GPEI) was established in 1988 by the World Health Assembly to interrupt transmission of wild poliovirus (WPV); completion of this initiative was declared a programmatic emergency of public health in January 2012. Polio cases are detected through surveillance for acute flaccid paralysis (AFP) with linked stool specimens tested for polioviruses (PVs) at accredited laboratories within the Global Polio Laboratory Network (GPLN). AFP surveillance findings are supplemented by testing sewage samples (environmental surveillance) collected at selected sites. Virologic data guide where targeted immunization activities should be conducted or improved. Key performance indicators are used to 1) monitor AFP surveillance quality at national and subnational levels to identify gaps where PV transmission could occur undetected; 2) provide evidence of where PV circulation has been interrupted; and 3) allow timely detection of an outbreak. Standardized surveillance indicators allow progress to be monitored over time and compared among countries. This report presents AFP surveillance performance indicators at national and subnational levels for countries affected by polio during 2011-2012, and trends in environmental surveillance, updating previous reports. In the 19 countries with transmission of PV (WPV and/or circulating vaccine-derived poliovirus [cVDPV]) during 2011-2012, national performance indicator targets were met in 12 (63%) countries in 2011 and 13 (68%) countries in 2012. Seven countries (37%) in 2011 had ≥80% of the population living in areas meeting performance indicators, increasing to nine countries (47%) in 2012. Performance indicators for timely reporting of PV isolation and characterization were met in four of six World Health Organization (WHO) regions in 2011 and five regions in 2012. To achieve global polio eradication, efforts are needed to improve and maintain AFP surveillance and laboratory performance.
Accuracy and precision of Legionella isolation by US laboratories in the ELITE program pilot study.
Lucas, Claressa E; Taylor, Thomas H; Fields, Barry S
2011-10-01
A pilot study for the Environmental Legionella Isolation Techniques Evaluation (ELITE) Program, a proficiency testing scheme for US laboratories that culture Legionella from environmental samples, was conducted September 1, 2008 through March 31, 2009. Participants (n=20) processed panels consisting of six sample types: pure and mixed positive, pure and mixed negative, pure and mixed variable. The majority (93%) of all samples (n=286) were correctly characterized, with 88.5% of samples positive for Legionella and 100% of negative samples identified correctly. Variable samples were incorrectly identified as negative in 36.9% of reports. For all samples reported positive (n=128), participants underestimated the cfu/ml by a mean of 1.25 logs with standard deviation of 0.78 logs, standard error of 0.07 logs, and a range of 3.57 logs compared to the CDC re-test value. Centering results around the interlaboratory mean yielded a standard deviation of 0.65 logs, standard error of 0.06 logs, and a range of 3.22 logs. Sampling protocol, treatment regimen, culture procedure, and laboratory experience did not significantly affect the accuracy or precision of reported concentrations. Qualitative and quantitative results from the ELITE pilot study were similar to reports from a corresponding proficiency testing scheme available in the European Union, indicating these results are probably valid for most environmental laboratories worldwide. The large enumeration error observed suggests that the need for remediation of a water system should not be determined solely by the concentration of Legionella observed in a sample since that value is likely to underestimate the true level of contamination. Published by Elsevier Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jordan, Preston D.; Javandel, Iraj
This study of the hydrogeology of Chicken Creek Canyon wasconducted by the Environmental Restoration Program (ERP) at LawrenceBerkeley National Laboratory (LBNL). This canyon extends downhill fromBuilding 31 at LBNL to Centennial Road below. The leading edge of agroundwater tritium plume at LBNL is located at the top of the canyon.Tritium activities measured in this portion of the plume during thisstudy were approximately 3,000 picocuries/liter (pCi/L), which issignificantly less than the maximum contaminant level (MCL) for drinkingwaterof 20,000 pCi/L established by the Environmental ProtectionAgency.There are three main pathways for tritium migration beyond theLaboratory s boundary: air, surface water and groundwater flow.more » Thepurpose of this report is to evaluate the groundwater pathway.Hydrogeologic investigation commenced with review of historicalgeotechnical reports including 35 bore logs and 27 test pit/trench logsas well as existing ERP information from 9 bore logs. This was followedby field mapping of bedrock outcrops along Chicken Creek as well asbedrock exposures in road cuts on the north and east walls of the canyon.Water levels and tritium activities from 6 wells were also considered.Electrical-resistivity profiles and cone penetration test (CPT) data werecollected to investigate the extent of an interpreted alluvial sandencountered in one of the wells drilled in this area. Subsequent loggingof 7 additional borings indicated that this sand was actually anunusually well-sorted and typically deeply weathered sandstone of theOrinda Formation. Wells were installed in 6 of the new borings to allowwater level measurement and analysis of groundwater tritium activity. Aslug test and pumping tests were also performed in the wellfield.« less
Foreman, William T.; Gray, James L.; ReVello, Rhiannon C.; Lindley, Chris E.; Losche, Scott A.; Barber, Larry B.
2012-01-01
A new analytical method has been developed and implemented at the U.S. Geological Survey National Water Quality Laboratory that determines a suite of 20 steroid hormones and related compounds in filtered water (using laboratory schedule 2434) and in unfiltered water (using laboratory schedule 4434). This report documents the procedures and initial performance data for the method and provides guidance on application of the method and considerations of data quality in relation to data interpretation. The analytical method determines 6 natural and 3 synthetic estrogen compounds, 6 natural androgens, 1 natural and 1 synthetic progestin compound, and 2 sterols: cholesterol and 3--coprostanol. These two sterols have limited biological activity but typically are abundant in wastewater effluents and serve as useful tracers. Bisphenol A, an industrial chemical used primarily to produce polycarbonate plastic and epoxy resins and that has been shown to have estrogenic activity, also is determined by the method. A technique referred to as isotope-dilution quantification is used to improve quantitative accuracy by accounting for sample-specific procedural losses in the determined analyte concentration. Briefly, deuterium- or carbon-13-labeled isotope-dilution standards (IDSs), all of which are direct or chemically similar isotopic analogs of the method analytes, are added to all environmental and quality-control and quality-assurance samples before extraction. Method analytes and IDS compounds are isolated from filtered or unfiltered water by solid-phase extraction onto an octadecylsilyl disk, overlain with a graded glass-fiber filter to facilitate extraction of unfiltered sample matrices. The disks are eluted with methanol, and the extract is evaporated to dryness, reconstituted in solvent, passed through a Florisil solid-phase extraction column to remove polar organic interferences, and again evaporated to dryness in a reaction vial. The method compounds are reacted with activated -methyl--trimethylsilyl trifluoroacetamide at 65 degrees Celsius for 1 hour to form trimethylsilyl or trimethylsilyl-enol ether derivatives that are more amenable to gas chromatographic separation than the underivatized compounds. Analysis is carried out by gas chromatography with tandem mass spectrometry using calibration standards that are derivatized concurrently with the sample extracts. Analyte concentrations are quantified relative to specific IDS compounds in the sample, which directly compensate for procedural losses (incomplete recovery) in the determined and reported analyte concentrations. Thus, reported analyte concentrations (or analyte recoveries for spiked samples) are corrected based on recovery of the corresponding IDS compound during the quantification process. Recovery for each IDS compound is reported for each sample and represents an absolute recovery in a manner comparable to surrogate recoveries for other organic methods used by the National Water Quality Laboratory. Thus, IDS recoveries provide a useful tool for evaluating sample-specific analytical performance from an absolute mass recovery standpoint. IDS absolute recovery will differ and typically be lower than the corresponding analyte’s method recovery in spiked samples. However, additional correction of reported analyte concentrations is unnecessary and inappropriate because the analyte concentration (or recovery) already is compensated for by the isotope-dilution quantification procedure. Method analytes were spiked at 10 and 100 nanograms per liter (ng/L) for most analytes (10 times greater spike levels were used for bisphenol A and 100 times greater spike levels were used for 3--coprostanol and cholesterol) into the following validation-sample matrices: reagent water, wastewater-affected surface water, a secondary-treated wastewater effluent, and a primary (no biological treatment) wastewater effluent. Overall method recovery for all analytes in these matrices averaged 100 percent, with overall relative standard deviation of 28 percent. Mean recoveries of the 20 individual analytes for spiked reagent-water samples prepared along with field samples and analyzed in 2009–2010 ranged from 84–104 percent, with relative standard deviations of 6–36 percent. Concentrations for two analytes, equilin and progesterone, are reported as estimated because these analytes had excessive bias or variability, or both. Additional database coding is applied to other reported analyte data as needed, based on sample-specific IDS recovery performance. Detection levels were derived statistically by fortifying reagent water at six different levels (0.1 to 4 ng/L) and range from about 0.4 to 4 ng/L for 16 analytes. Interim reporting levels applied to analytes in this report range from 0.8 to 8 ng/L. Bisphenol A and the sterols (cholesterol and 3-beta-coprostanol) were consistently detected in laboratory and field blanks. The minimum reporting levels were set at 100 ng/L for bisphenol A and at 200 ng/L for the two sterols to prevent any bias associated with the presence of these compounds in the blanks. A minimum reporting level of 2 ng/L was set for 11-ketotestosterone to minimize false positive risk from an interfering siloxane compound emanating as chromatographic-column bleed, from vial septum material, or from other sources at no more than 1 ng/L.
National survey on current situation of critical value reporting in 973 laboratories in China.
Fei, Yang; Zhao, Haijian; Wang, Wei; He, Falin; Zhong, Kun; Yuan, Shuai; Wang, Zhiguo
2017-10-15
The aim of the study was to investigate the state-of-the-art of the performance of critical value reporting and provide recommendations for laboratories setting critical value reporting time frames. The National Centre for Clinical Laboratories in China initiated a critical value reporting investigation in 2015. A questionnaire related to critical value reporting policy was sent to 1589 clinical laboratories in China online. The questionnaire consisted of a set of questions related to critical value reporting policy and a set of questions related to timeliness of critical value reporting. The survey data were collected between March and April 2015. A total survey response rate was 61.2%. The critical value unreported rate, unreported timely rate, and clinical unacknowledged rate of more than half of participants were all 0.0%. More than 75.0% of participants could report half of critical values to clinicians within 20 minutes and could report 90.0% of critical values to clinicians within 25 minutes (from result validation to result communication to the clinician). The median of target critical value reporting time was 15 minutes. "Reporting omission caused by laboratory staff", "communications equipment failure to connect", and "uncompleted application form without contact information of clinician" were the three major reasons for unreported critical value. The majority of laboratories can report critical values to responsible clinical staff within 25 minutes. Thus, this value could be recommended as suitable critical value reporting time frame for biochemistry laboratories in China. However, careful monitoring of the complete reporting process and improvement of information systems should ensure further improvement of critical value reporting timeliness.
Shielding concepts for low-background proportional counter arrays in surface laboratories
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aalseth, Craig E.; Humble, Paul H.; Mace, Emily K.
2016-02-01
Development of ultra low background gas proportional counters has made the contribution from naturally occurring radioactive isotopes – primarily and activity in the uranium and thorium decay chains – inconsequential to instrumental sensitivity levels when measurements are performed in above ground surface laboratories. Simple lead shielding is enough to mitigate against gamma rays as gas proportional counters are already relatively insensitive to naturally occurring gamma radiation. The dominant background in these surface laboratory measurements using ultra low background gas proportional counters is due to cosmic ray generated muons, neutrons, and protons. Studies of measurements with ultra low background gas proportionalmore » counters in surface and underground laboratories as well as radiation transport Monte Carlo simulations suggest a preferred conceptual design to achieve the highest possible sensitivity from an array of low background gas proportional counters when operated in a surface laboratory. The basis for a low background gas proportional counter array and the preferred shielding configuration is reported, especially in relation to measurements of radioactive gases having low energy decays such as 37Ar.« less
Choge, Joseph K; Magak, Ng'wena G; Akhwale, Willis; Koech, Julius; Ngeiywa, Moses M; Oyoo-Okoth, Elijah; Esamai, Fabian; Osano, Odipo; Khayeka-Wandabwa, Christopher; Kweka, Eliningaya J
2014-04-09
The commonly accepted gold standard diagnostic method for detecting malaria is a microscopic reading of Giemsa-stained blood films. However, symptomatic diagnosis remains the basis of therapeutic care for the majority of febrile patients in malaria endemic areas. This study aims to compare the discrepancy in malaria and anaemia burdens between symptomatic diagnosed patients with those diagnosed through the laboratory. Data were collected from Western Kenya during a follow-up study of 887 children with suspected cases of malaria visiting the health facilities. In the laboratory, blood samples were analysed for malaria parasite and haemoglobin levels. Differences in malaria prevalence between symptomatic diagnosis and laboratory diagnosis were analysed by Chi-square test. Bayesian probabilities were used for the approximation of the malaria and anaemia burdens. Regression analysis was applied to: (1) determine the relationships between haemoglobin levels, and malaria parasite density and (2) relate the prevalence of anaemia and the prevalence of malaria. The prevalence of malaria and anaemia ranged from 10% to 34%, being highest during the rainy seasons. The predominant malaria parasite was P. falciparum (92.3%), which occurred in higher density in children aged 2‒5 years. Fever, high temperature, sweating, shivering, vomiting and severe headache symptoms were associated with malaria during presumptive diagnosis. After conducting laboratory diagnosis, lower malaria prevalence was reported among the presumptively diagnosed patients. Surprisingly, there were no attempts to detect anaemia in the same cohort. There was a significant negative correlation between Hb levels and parasite density. We also found a positive correlation between the prevalence of anaemia and the prevalence of malaria after laboratory diagnosis indicating possible co-occurrence of malaria and anaemia. Symptomatic diagnosis of malaria overestimates malaria prevalence, but underestimates the anaemia burden in children. Good clinical practice dictates that a laboratory should confirm the presence of parasites for all suspected cases of malaria.
Yanagisawa, Hideji
2009-05-01
With the revision of the Medical Service Law in 2006 by the Japanese Ministry of Health, Labour and Welfare (MHLW), all healthcare institutions are now required to implement a healthcare risk management program including infection control program. At a national level, an infection control surveillance program (JANIS) was implemented in July 2007. Regular weekly, monthly, and yearly infection control surveillance reports from independent microbiology laboratories can make significant contributions to infection control programs in small to mid-sized hospitals; furthermore, such programs are consistent with the framework of the MHLW's objective of strengthening risk management in healthcare institutions. Against the backdrop of current efforts to improve risk management, independent laboratories can make a significant contribution. Independent laboratories must play a role beyond merely receiving and processing specimens for microbiological examination. In addition to generating results for patients, hospital epidemiological data that contribute to local infection control programs must be a value-added component of the service. A major obstacle for independent laboratories to make a significant contribution to risk management is the current reimbursement system, which makes it economically impossible for independent laboratories to support infection control programs in healthcare institutions.
Revised guidelines for good practice in IVF laboratories (2015).
De los Santos, Maria José; Apter, Susanna; Coticchio, Giovanni; Debrock, Sophie; Lundin, Kersti; Plancha, Carlos E; Prados, Fernando; Rienzi, Laura; Verheyen, Greta; Woodward, Bryan; Vermeulen, Nathalie
2016-04-01
Which recommendations can be provided by the European Society of Human Reproduction and Embryology Special Interest Group (ESHRE SIG) Embryology to support laboratory specialists in the organization and management of IVF laboratories and the optimization of IVF patient care? Structured in 13 sections, the guideline development group formulated recommendations for good practice in the organization and management of IVF laboratories, and for good practice of the specific procedures performed within the IVF laboratory. NA. The guideline was produced by a group of 10 embryologists representing different European countries, settings and levels of expertise. The group evaluated the document of 2008, and based on this assessment, each group member rewrote one or more sections. Two 2-day meetings were organized during which each of the recommendations was discussed and rewritten until consensus within the guideline group was reached. After finalizing the draft, the members of the ESHRE SIG embryology were invited to review the guideline. NA. The guideline provides recommendations on the general organization of an IVF laboratory (staffing and direction, quality management, laboratory safety), and on the specific aspects of the procedures performed in IVF laboratories (Identification of patients and traceability of their reproductive cells, consumables, handling of biological material, oocyte retrieval, sperm preparation, insemination of oocytes, scoring for fertilization, embryo culture and transfer, and cryopreservation). A last section provides recommendations regarding an Emergency plan for IVF laboratories. Evidence on most of the issues described is scarce, and therefore it was decided not to perform a formal search for and assessment of scientific evidence. However, recommendations published in the EUTCD and relevant and recent documents, manuals and consensus papers were taken into account when formulating the recommendations. Despite the limitations, the guideline group is confident that this document will be helpful to directors and managers involved in the management and organization of IVF laboratories, but also to embryologists and laboratory technicians performing daily tasks. The guideline was developed and funded by ESHRE, covering expenses associated with the guideline meetings. The guideline group members did not receive payment. Dr Coticchio reports speaker's fees from IBSA and Cook, outside the submitted work; Dr Lundin reports grants from Vitrolife, personal fees from Merck Serono, non-financial support from Unisense, outside the submitted work; Dr. Rienzi reports personal fees from Merck Serono, personal fees from MSD, grants from GFI, outside the submitted work; the other authors had nothing to disclose. NA. © The Author 2016. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Waste Isolation Pilot Plant Technical Assessment Team Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
This report provides the results of the Waste Isolation Pilot Plant (WIPP) technical assessment led by the Savannah River National Laboratory and conducted by a team of experts in pertinent disciplines from SRNL and Lawrence Livermore National Laboratory (LLNL), Oak Ridge National Laboratory (ORNL), Pacific Northwest National Laboratory (PNNL), and Sandia National Laboratories (SNL).
Gutierrez, Oriol; Sudarjanto, Gatut; Ren, Guo; Ganigué, Ramon; Jiang, Guangming; Yuan, Zhiguo
2014-01-01
Caustic dosing to raise pH above 10.0 for short periods (hours) is often used by water utilities for controlling sulfide formation in sewers. However the effectiveness of this strategy is rarely reported and the impact of pH level and exposure time on the effectiveness is largely unknown. The effectiveness of this strategy under various pH levels (10.5-12.5) and exposure time (0.5-6.0 h) in controlling sulfide and methane production was evaluated in laboratory scale anaerobic sewer reactors and then in a real sewer system. Laboratory studies showed that the sulfide production rate of the laboratory sewer biofilm was reduced by 70-90% upon the completion of the pH shock, while the methane production rate decreased by 95-100%. It took approximately one week for the sulfate-reducing activity to recover to normal levels. In comparison, the methanogenic activities recovered to only about 10% in 4 weeks. The slow recovery is explained by the substantially loss of cell viability upon pH shocks, which recovered slowly after the shocks. Laboratory studies further revealed that a pH level of 10.5 for 1-2 h represent cost-effective conditions for the pH shock treatment. However, field trials showed a higher pH (11.5) and larger dosing times are needed due to the pH decreases along the sewer line and at the two ends of the caustic-receiving wastewater slugs due to dilution. To have effective sulfide and methane control, it is important to ensure effective conditions (pH > 10.5 and duration >1-2 h) for the entire sewer line. Copyright © 2013 Elsevier Ltd. All rights reserved.
Cordero, Maria I; Moser, Dominik A; Manini, Aurelia; Suardi, Francesca; Sancho-Rossignol, Ana; Torrisi, Raffaella; Rossier, Michel F; Ansermet, François; Dayer, Alexandre G; Rusconi-Serpa, Sandra; Schechter, Daniel S
2017-04-01
Women who have experienced interpersonal violence (IPV) are at a higher risk to develop posttraumatic stress disorder (PTSD), with dysregulation of the hypothalamic-pituitary-adrenal (HPA) axis and impaired social behavior. Previously, we had reported impaired maternal sensitivity and increased difficulty in identifying emotions (i.e. alexithymia) among IPV-PTSD mothers. One of the aims of the present study was to examine maternal IPV-PTSD salivary cortisol levels diurnally and reactive to their child's distress in relation to maternal alexithymia. Given that mother-child interaction during infancy and early childhood has important long-term consequences on the stress response system, toddlers' cortisol levels were assessed during the day and in response to a laboratory stressor. Mothers collected their own and their 12-48month-old toddlers' salivary samples at home three times: 30min after waking up, between 2-3pm and at bedtime. Moreover, mother-child dyads participated in a 120-min laboratory session, consisting of 3 phases: baseline, stress situation (involving mother-child separation and exposure to novelty) and a 60-min regulation phase. Compared to non-PTSD controls, IPV-PTSD mothers - but not their toddlers, had lower morning cortisol and higher bedtime cortisol levels. As expected, IPV-PTSD mothers and their children showed blunted cortisol reactivity to the laboratory stressor. Maternal cortisol levels were negatively correlated to difficulty in identifying emotions. Our data highlights PTSD-IPV-related alterations in the HPA system and its relevance to maternal behavior. Toddlers of IPV-PTSD mothers also showed an altered pattern of cortisol reactivity to stress that potentially may predispose them to later psychological disorders. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1992-04-07
This report contains the following appendices: Appendix A - Requirements for Undergraduate Level; Appendix B - Requirements for Graduate Level; Appendix C - Graduate Degree In Environmental Engineering; Appendix D - Non-degree Certificate Program; Appendix E - Curriculum for Associate Degree Program; Appendix F - Curriculum for NCC Program; Appendix G - Information 1991 Teleconference Series; Appendix H - Information on 1992 Teleconference Series; Appendix I - WERC interactive Television Courses; Appendix J - WERC Research Seminar Series; Appendix K - Sites for Hazardous/Radioactive Waste Management Series; Appendix L- Summary of Technology Development of the Second Year; Appendix M -more » List of Major Publications Resulting from WERC; Appendix N - Types of Equipment at WERC Laboratories.« less
Waste-Management Education and Research Consortium (WERC) annual progress report, 1991--1992
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maji, A. K.; Thomson, Bruce M.; Samani, Zohrab A.
1992-04-07
This report contains the following appendices: Appendix A - Requirements for Undergraduate Level; Appendix B - Requirements for Graduate Level; Appendix C - Graduate Degree In Environmental Engineering; Appendix D - Non-degree Certificate Program; Appendix E - Curriculum for Associate Degree Program; Appendix F - Curriculum for NCC Program; Appendix G - Information 1991 Teleconference Series; Appendix H - Information on 1992 Teleconference Series; Appendix I - WERC interactive Television Courses; Appendix J - WERC Research Seminar Series; Appendix K - Sites for Hazardous/Radioactive Waste Management Series; Appendix L- Summary of Technology Development of the Second Year; Appendix M -more » List of Major Publications Resulting from WERC; Appendix N - Types of Equipment at WERC Laboratories.« less
[A Case of Rhabdomyolysis Related to SOX Therapy for Liver Metastasis of Gastric Cancer].
Sato, Kei; Akiyama, Hirotoshi; Kogure, Yuu; Suwa, Yusuke; Momiyama, Masashi; Ishibe, Atsushi; Endo, Itaru
2017-04-01
We report a case of rhabdomyolysis related to S-1 plus oxaliplatin(SOX)therapy for liver metastasis of gastric cancer. A 76- year-old man who had received SOX therapy for metastatic gastric cancer was admitted to our hospital for a chief complaint of fatigue and weakness. He diagnosed with rhabdomyolysis related to SOX therapy because of his symptoms and because his laboratory studies showed significant elevation of his serum creatine kinase(CK)level. The symptoms disappeared and the CK level normalized following large-volume transfusions. Rhabdomyolysis following SOX therapy is a very rare, but severe adverse event. This is the first detailed case report of rhabdomyolysis related to SOX therapy.
Galárraga, Omar; Wirtz, Veronika J.; Figueroa-Lara, Alejandro; Santa-Ana-Tellez, Yared; Coulibaly, Ibrahima; Viisainen, Kirsi; Medina-Lara, Antonieta; Korenromp, Eline L.
2013-01-01
Background As antiretroviral treatment (ART) for HIV/AIDS is scaled-up globally, information on per-person costs is critical to improve efficiency in service delivery and maximize coverage and health impact. Objective To review studies on delivery unit costs for adult and pediatric ART provision per-patient-year, and prevention of mother-to-child transmission (PMTCT) interventions per mother-infant pair screened or treated, in low- and middle-income countries. Methods Systematic review of English, French and Spanish publications from 2001 to 2009, reporting empirical costing that accounted for at least antiretroviral (ARV) medicines, laboratory testing and personnel. Expenditures were analyzed by country income level and cost component. All costs were standardized to 2009 US dollars. Results Analyses covered 29 eligible, comprehensive costing studies. In the base case, in low-income countries (LIC), median, ART cost per patient-year was $792 (mean: $839, range: $682-$1089); for lower-middle-income countries (LMIC), the median was $932 (mean: $1246, range: $156-$3904); and for upper-middle-income countries (UMIC) the median was $1454 (mean: $2783, range: $1230-$5667). ARV drugs were largest component of overall ART cost in all settings (62%, 50% and 47% in LIC, LMIC and UMIC respectively). Out of 26 ART studies, 14 report which drug regimes were used, and only one study explicitly reported second line treatment costs. The second cost driver was laboratory cost in LIC and LMIC (14% and 19.5%) whereas it was personnel costs in UMIC (26%). Two studies specified the types of laboratory tests costed, and three studies specifically included above-facility-level personnel costs. Three studies reported detailed PMTCT costs, and two studies reported on pediatric ART. Conclusions There is a paucity of data on the full ART and PMTCT delivery unit costs, in particular for low-and middle-income countries. Heterogeneity in activities costed and insufficient detail regarding components included in the costing hampers standardization of unit cost measures. Evaluation of program-level unit costs would benefit from international guidance on standardized costing methods, and expenditure categories and definitions. Future work should help elucidate the sources for the large variations in delivery unit costs across settings with similar income and epidemiological characteristics. PMID:21671687
21 CFR 58.185 - Reporting of nonclinical laboratory study results.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 1 2013-04-01 2013-04-01 false Reporting of nonclinical laboratory study results. 58.185 Section 58.185 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Reporting of nonclinical laboratory study results. (a) A final report shall be prepared for each nonclinical...
21 CFR 58.185 - Reporting of nonclinical laboratory study results.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 1 2012-04-01 2012-04-01 false Reporting of nonclinical laboratory study results. 58.185 Section 58.185 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Reporting of nonclinical laboratory study results. (a) A final report shall be prepared for each nonclinical...
21 CFR 58.185 - Reporting of nonclinical laboratory study results.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 1 2011-04-01 2011-04-01 false Reporting of nonclinical laboratory study results. 58.185 Section 58.185 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Reporting of nonclinical laboratory study results. (a) A final report shall be prepared for each nonclinical...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rigo, H.G.; Chandler, A.J.
1996-04-01
Volume II (part 1 of 2) of ''Retrofit of Waste-to-energy Facilities Equipped with Electrostatic Precipitators'' contains the documentation and raw data, including: (1) field reports, (2) analytic laboratory reports, (3) chain of custody forms, and (4) TCLP laboratory reports.
Allen, Stephanie; Jenkins, Lucy; Khawaja, Farrah; Hastings, Ros J.; Mann, Kathy; Patton, Simon J.; Sistermans, Erik A.; Chitty, Lyn S.
2017-01-01
Abstract Objective Non‐invasive prenatal testing (NIPT) for trisomies 13, 18 and 21 is used worldwide. Laboratory reports should provide clear, concise results with test limitations indicated, yet no national or local guidelines are currently available. Here, we aim to present minimum best practice guidelines. Methods All laboratories registered in the three European quality assurance schemes for molecular and cytogenetics were invited to complete an online survey focused on services provided for NIPT and non‐invasive prenatal diagnosis. Laboratories delivering NIPT for aneuploidy were asked to submit two example reports; one high and one low risk result. Reports were reviewed for content and discussed at a meeting of laboratory providers and clinicians held at the ISPD 2016 conference in Berlin. Results Of the 122 laboratories that responded, 50 issued reports for NIPT and 43 of these submitted sample reports. Responses and reports were discussed by 72 attendees at the meeting. Consensus opinion was determined in several areas and used to develop best practice guidelines for reporting of NIPT results. Conclusions Across Europe, there is considerable variation in reporting NIPT results. Here, we describe minimum best practice guidelines, which will be distributed to European laboratories, and reports audited in subsequent external quality assurance cycles. © 2017 The Authors. Prenatal Diagnosis published by John Wiley & Sons, Ltd. PMID:28497584
Implementing self sustained quality control procedures in a clinical laboratory.
Khatri, Roshan; K C, Sanjay; Shrestha, Prabodh; Sinha, J N
2013-01-01
Quality control is an essential component in every clinical laboratory which maintains the excellence of laboratory standards, supplementing to proper disease diagnosis, patient care and resulting in overall strengthening of health care system. Numerous quality control schemes are available, with combinations of procedures, most of which are tedious, time consuming and can be "too technical" whereas commercially available quality control materials can be expensive especially for laboratories in developing nations like Nepal. Here, we present a procedure performed at our centre with self prepared control serum and use of simple statistical tools for quality assurance. The pooled serum was prepared as per guidelines for preparation of stabilized liquid quality control serum from human sera. Internal Quality Assessment was performed on this sample, on a daily basis which included measurement of 12 routine biochemical parameters. The results were plotted on Levey-Jennings charts and analysed with quality control rules, for a period of one month. The mean levels of biochemical analytes in self prepared control serum were within normal physiological range. This serum was evaluated every day along with patients' samples. The results obtained were plotted on control charts and analysed using common quality control rules to identify possible systematic and random errors. Immediate mitigation measures were taken and the dispatch of erroneous reports was avoided. In this study we try to highlight on a simple internal quality control procedure which can be performed by laboratories, with minimum technology, expenditure, and expertise and improve reliability and validity of the test reports.
Sparrow, Annie; Almilaji, Khaled; Tajaldin, Bachir; Teodoro, Nicholas; Langton, Paul
2016-01-01
Background Public health breakdown from the Syrian government's targeting of healthcare systems in politically unsympathetic areas has yielded a resurgence of infectious diseases. Suspected cholera recently reappeared but conflict-related constraints impede laboratory confirmation. Given the government's previous under-reporting of infectious outbreaks and the reliance of the WHO on government reporting, we sought to assess the reliability of current surveillance systems. Methods We compared weekly surveillance reports of waterborne diseases from the Syrian government's (WHO-associated) Early Warning and Response System (EWARS), based in Damascus, and the independent, non-governmental Early Warning and Response Network (EWARN) headquartered in Gaziantep, Turkey. We compared raw case rates by EWARS and EWARN and assessed the quality of reporting against the WHO benchmarks. Results We identified significant under-reporting and delays in the government's surveillance. On average, EWARS reports were published 24 days (range 12–61) after the reference week compared with 11 days (5–21) for EWARN. Average completeness for EWARS was 75% (55–84%), compared with 92% for EWARN (85–99%). Average timeliness for EWARS was 79% (51–100%), compared with 88% for EWARN (70–97%). EWARS made limited use of rapid diagnostic tests, and rates of collection of stool samples for laboratory cholera testing were well below reference levels. Conclusions In the context of the current Syrian war, the government's surveillance is inadequate due to lack of access to non-government held territory, an incentive to under-report the consequence of government attacks on health infrastructure, and an impractical insistence on laboratory confirmation. These findings should guide the WHO reform for surveillance in conflict zones. PMID:28588951
NASA Astrophysics Data System (ADS)
Cabral, TS; da Silva, CNM; Potiens, MPA; Soares, CMA; Silveira, RR; Khoury, H.; Saito, V.; Fernandes, E.; Cardoso, WF; de Oliveira, HPS; Pires, MA; de Amorim, AS; Balthar, M.
2018-03-01
The results of the comparison involving 9 laboratories in Brazil are reported. The measured quantity was the air kerma in 137Cs and 60Co, at the level of radioprotection. The comparison was conducted by the National Laboratory Metrology of Ionizing Radiation (LNMRI/IRD) from October 2016 to March 2017. The largest deviation between the calibration coefficients was 0.8% for 137Cs and 0.7% for 60Co. This proficiency exercise proved the technical capacity of the Brazilian calibration network in radiation monitors and the results were used by some in the implementation of the standard ISO/IEC 17025.
NASA Astrophysics Data System (ADS)
Bates, Harry E.
1984-05-01
Holography is a new and exciting field that has found many applications in physics and engineering. Atomic spectroscopy has been the experimental cornerstone of modern physics and chemistry. This paper reports on an intermediate undergraduate laboratory experiment that combines fundamental ideas and techniques of both fields. The student utilizes holographic techniques to make a small sinusoidal diffraction grating and then uses this grating to analyze the spectrum of hydrogen. The Rydberg constant can be determined from the wavelength, the angle between the laser beams used to make the grating, and the observed diffractions angles of lines of the Balmer series.
Medium resolution spectra of the shuttle glow in the visible region of the spectrum
NASA Technical Reports Server (NTRS)
Viereck, R. A.; Murad, E.; Pike, C. P.; Mende, S. B.; Swenson, G. R.; Culbertson, F. L.; Springer, B. C.
1992-01-01
Recent spectral measurements of the visible shuttle glow (lambda = 400 - 800 nm) at medium resolution (1 nm) reveal the same featureless continuum with a maximum near 680 nm that was reported previously. This is also in good agreement with recent laboratory experiments that attribute the glow to the emissions of NO2 formed by the recombination of O + NO. The data that are presented were taken from the aft flight deck with a hand-held spectrograph and from the shuttle bay with a low-light-level television camera. Shuttle glow images and spectra are presented and compared with laboratory data and theory.
Hydrogeochemical and stream sediment reconnaissance basic data for Aztec Quadrangle, New Mexico
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1981-07-31
Field and laboratory data are presented for 331 water samples and 1693 sediment samples from the Aztec Quadrangle, New Mexico. Uranium values have been reported by Los Alamos National Laboratory in Report GJBX-129(78). The samples were collected by Los Alamos National Laboratory; laboratory analysis and data reporting were performed by the Uranium Resource Evaluation Project at Oak Ridge, Tennessee.
1992-01-01
Research Program Phillips Laboratory I4oJ A*6Iv4 Sponsored by: Air Force Office of Scientific Research Kirtland Air ...UNITED STATES AIR FORCE SUMMER RESEARCH PROGki"A -- 1992 HIGH SCHOOL APPRENTICESHIP PROGRAM (HSAP) REPORTS VOLUME 13 (t PHILLIPS LABORATORY . RESEARCH ...Arlington High School Final Report for: Summer Research Program Geophysics Directorate Phillips Laboratory
Upper-Level Undergraduate Chemistry Students' Goals for Their Laboratory Coursework
ERIC Educational Resources Information Center
DeKorver, Brittland K.; Towns, Marcy H.
2016-01-01
Efforts to reform undergraduate chemistry laboratory coursework typically focus on the curricula of introductory-level courses, while upper-level courses are bypassed. This study used video-stimulated recall to interview 17 junior- and senior- level chemistry majors after they carried out an experiment as part of a laboratory course. It is assumed…
Foreman, D; Garris, D
1984-08-01
Plasma progesterone levels in female prairie dogs were determined by a radioimmunoassay specific for progesterone. Plasma progesterone levels were determined in samples taken before estrus, at estrus, during the luteal phase, and during anestrus from females maintained all year in the laboratory. Progesterone levels were also determined in plasma samples taken in the laboratory from two pregnant and three postparturient females captured in the field. Progesterone levels were low before estrus and continued low during estrus. They rose on the first week after estrus to 0.8 ng/ml or above and continued at or above this level for 9-14 weeks following estrus. Gestation in prairie dogs is 35 days in this species. Progesterone levels of three postparturient females were above 1.0 ng/ml for 7 weeks after their arrival in the laboratory. These females all had uterine scars showing that they had delivered their litters before they were captured. Two females were determined to be pregnant at the time of their capture. These females later reabsorbed their fetuses (determined by laparotomy). Progesterone values of samples from these females were all above 1.0 ng/ml except for one low value in one female which occurred 3 weeks after her capture and after reabsorption of her fetuses was in progress. The cells of the corpus lutea (CL) of nonpregnant, pregnant, and postparturient females had well-developed rings of cytoplasmic basophilia but as the CL regressed this pattern became disorganized and disappeared. The function of this basophilia is not known. The long luteal phase found in female prairie dogs is compared to those found in other species of mammals. This is the first annually breeding rodent reported to have a longer luteal phase that the period of gestation.
Acute selenium toxicosis in polo ponies.
Desta, Belainesh; Maldonado, Gizela; Reid, Herman; Puschner, Birgit; Maxwell, James; Agasan, Alice; Humphreys, Leigh; Holt, Thomas
2011-05-01
Just prior to an international polo event, 21 horses from one team exhibited clinical signs of central nervous system disturbance, hyperexcitability, sweating, ataxia, tachycardia, dyspnea, pyrexia, and rapid death. The suspected cause of this peracute onset of illness and death included intentional contamination of feed or iatrogenic administration of performance-enhancing drugs resulting in a severe adverse reaction. Six horses were submitted to the Bronson Animal Disease Diagnostic Laboratory for necropsy and toxicological examination. The clinical signs and sudden death, the similarity to earlier work by the lead author of selenium toxicosis in calves, as well as published reports, prompted investigators to focus on selenium testing. Sixty-four hours following receipt, the laboratory detected toxic selenium concentrations in the tissues of these animals. Following further investigation of the case by regulatory officials, it was determined that all affected horses had received an intravenous injection of a compounded "vitamin/mineral" supplement just prior to the onset of signs. The compounded supplement contained toxic levels of selenium. The present report illustrates the in-depth laboratory investigation of the cause of acute death in 6 polo ponies due to selenium toxicosis. In addition to solving this high profile case, the toxic levels of selenium found in livers (6.13 ± 0.31 mg/kg wet weight), kidneys (6.25 ± 0.3 mg/kg wet weight), and sera (1.50 ± 0.11 µg/ml) of these affected animals may provide important diagnostic criteria for future interpretations of selenium concentrations in tissues of horses. © 2011 The Author(s)
Brugnera, Agostino; Zarbo, Cristina; Tarvainen, Mika P; Marchettini, Paolo; Adorni, Roberta; Compare, Angelo
2018-05-01
Acute psychosocial stress is typically investigated in laboratory settings using protocols with distinctive characteristics. For example, some tasks involve the action of speaking, which seems to alter Heart Rate Variability (HRV) through acute changes in respiration patterns. However, it is still unknown which task induces the strongest subjective and autonomic stress response. The present cross-over randomized trial sought to investigate the differences in perceived stress and in linear and non-linear analyses of HRV between three different verbal (Speech and Stroop) and non-verbal (Montreal Imaging Stress Task; MIST) stress tasks, in a sample of 60 healthy adults (51.7% females; mean age = 25.6 ± 3.83 years). Analyses were run controlling for respiration rates. Participants reported similar levels of perceived stress across the three tasks. However, MIST induced a stronger cardiovascular response than Speech and Stroop tasks, even after controlling for respiration rates. Finally, women reported higher levels of perceived stress and lower HRV both at rest and in response to acute psychosocial stressors, compared to men. Taken together, our results suggest the presence of gender-related differences during psychophysiological experiments on stress. They also suggest that verbal activity masked the vagal withdrawal through altered respiration patterns imposed by speaking. Therefore, our findings support the use of highly-standardized math task, such as MIST, as a valid and reliable alternative to verbal protocols during laboratory studies on stress. Copyright © 2018 Elsevier B.V. All rights reserved.
Farooq, Muhammad; Sazonov, Edward
2017-11-01
Several methods have been proposed for automatic and objective monitoring of food intake, but their performance suffers in the presence of speech and motion artifacts. This paper presents a novel sensor system and algorithms for detection and characterization of chewing bouts from a piezoelectric strain sensor placed on the temporalis muscle. The proposed data acquisition device was incorporated into the temple of eyeglasses. The system was tested by ten participants in two part experiments, one under controlled laboratory conditions and the other in unrestricted free-living. The proposed food intake recognition method first performed an energy-based segmentation to isolate candidate chewing segments (instead of using epochs of fixed duration commonly reported in research literature), with the subsequent classification of the segments by linear support vector machine models. On participant level (combining data from both laboratory and free-living experiments), with ten-fold leave-one-out cross-validation, chewing were recognized with average F-score of 96.28% and the resultant area under the curve was 0.97, which are higher than any of the previously reported results. A multivariate regression model was used to estimate chew counts from segments classified as chewing with an average mean absolute error of 3.83% on participant level. These results suggest that the proposed system is able to identify chewing segments in the presence of speech and motion artifacts, as well as automatically and accurately quantify chewing behavior, both under controlled laboratory conditions and unrestricted free-living.
Lianidou, Evi; Ahmad-Nejad, Parviz; Ferreira-Gonzalez, Andrea; Izuhara, Kenji; Cremonesi, Laura; Schroeder, Maria-Eugenia; Richter, Karin; Ferrari, Maurizio; Neumaier, Michael
2014-09-25
Molecular techniques are becoming commonplace in the diagnostic laboratory. Their applications influence all major phases of laboratory medicine including predisposition/genetic risk, primary diagnosis, therapy stratification and prognosis. Readily available laboratory hardware and wetware (i.e. consumables and reagents) foster rapid dissemination to countries that are just establishing molecular testing programs. Appropriate skill levels extending beyond the technical procedure are required for analytical and diagnostic proficiency that is mandatory in molecular genetic testing. An international committee (C-CMBC) of the International Federation for Clinical Chemistry (IFCC) was established to disseminate skills in molecular genetic testing in member countries embarking on the respective techniques. We report the ten-year experience with different teaching and workshop formats for beginners in molecular diagnostics. Copyright © 2014 Elsevier B.V. All rights reserved.
Tembuyser, Lien; Dequeker, Elisabeth M C
2016-01-01
Quality assurance is an indispensable element in a molecular diagnostic laboratory. The ultimate goal is to warrant patient safety. Several risks that can compromise high quality procedures are at stake, from sample collection to the test performed by the laboratory, the reporting of test results to clinicians, and the organization of effective external quality assessment schemes. Quality assurance should therefore be safeguarded at each level and should imply a holistic multidisciplinary approach. This review aims to provide an overview of good quality assurance practices and discusses certain risks and recommendations to promote and improve quality assurance for both diagnostic laboratories and for external quality assessment providers. The number of molecular targets is continuously rising, and new technologies are evolving. As this poses challenges for clinical implementation and increases the demand for external quality assessment, the formation of an international association for improving quality assurance in molecular pathology is called for.
Relativistic MR–MP Energy Levels for L-shell Ions of Silicon
Santana, Juan A.; Lopez-Dauphin, Nahyr A.; Beiersdorfer, Peter
2018-01-15
Level energies are reported for Si v, Si vi, Si vii, Si viii, Si ix, Si x, Si xi, and Si xii. The energies have been calculated with the relativistic Multi-Reference Møller–Plesset Perturbation Theory method and include valence and K-vacancy states with nl up to 5f. The accuracy of the calculated level energies is established by comparison with the recommended data listed in the National Institute of Standards and Technology (NIST) online database. The average deviation of valence level energies ranges from 0.20 eV in Si v to 0.04 eV in Si xii. For K-vacancy states, the available values recommendedmore » in the NIST database are limited to Si xii and Si xiii. The average energy deviation is below 0.3 eV for K-vacancy states. The extensive and accurate data set presented here greatly augments the amount of available reference level energies. Here, we expect our data to ease the line identification of L-shell ions of Si in celestial sources and laboratory-generated plasmas, and to serve as energy references in the absence of more accurate laboratory measurements.« less
Whole-body cortisol response of zebrafish to acute net handling stress
Ramsay, J.M.; Feist, G.W.; Varga, Z.M.; Westerfield, M.; Kent, M.L.; Schreck, C.B.
2009-01-01
Zebrafish, Danio rerio, are frequently handled during husbandry and experimental procedures in the laboratory, yet little is known about the physiological responses to such stressors. We measured the whole-body cortisol levels of adult zebrafish subjected to net stress and air exposure at intervals over a 24 h period; cortisol recovered to near control levels by about 1 h post-net-stress (PNS). We then measured cortisol at frequent intervals over a 1 h period. Cortisol levels were more than 2-fold higher in net stressed fish at 3 min PNS and continued to increase peaking at 15 min PNS, when cortisol levels were 6-fold greater than the control cortisol. Mean cortisol declined from 15 to 60 min PNS, and at 60 min, net-stressed cortisol was similar to control cortisol. Because the age of fish differed between studies, we examined resting cortisol levels of fish of different ages (3, 7, 13, and 19 months). The resting cortisol values among tanks with the same age fish differed significantly but there was no clear effect of age. Our study is the first to report the response and recovery of cortisol after net handling for laboratory-reared zebrafish. ?? 2009 Elsevier B.V.
Relativistic MR–MP Energy Levels for L-shell Ions of Silicon
NASA Astrophysics Data System (ADS)
Santana, Juan A.; Lopez-Dauphin, Nahyr A.; Beiersdorfer, Peter
2018-01-01
Level energies are reported for Si V, Si VI, Si VII, Si VIII, Si IX, Si X, Si XI, and Si XII. The energies have been calculated with the relativistic Multi-Reference Møller–Plesset Perturbation Theory method and include valence and K-vacancy states with nl up to 5f. The accuracy of the calculated level energies is established by comparison with the recommended data listed in the National Institute of Standards and Technology (NIST) online database. The average deviation of valence level energies ranges from 0.20 eV in Si V to 0.04 eV in Si XII. For K-vacancy states, the available values recommended in the NIST database are limited to Si XII and Si XIII. The average energy deviation is below 0.3 eV for K-vacancy states. The extensive and accurate data set presented here greatly augments the amount of available reference level energies. We expect our data to ease the line identification of L-shell ions of Si in celestial sources and laboratory-generated plasmas, and to serve as energy references in the absence of more accurate laboratory measurements.
VizieR Online Data Catalog: Relativistic MR-MP energy levels for Si (Santana+, 2018)
NASA Astrophysics Data System (ADS)
Santana, J. A.; Lopez-Dauphin, N. A.; Beiersdorfer, P.
2018-03-01
Level energies are reported for Si V, Si VI, Si VII, Si VIII, Si IX, Si X, Si XI, and Si XII. The energies have been calculated with the relativistic Multi- Reference Moller-Plesset Perturbation Theory method and include valence and K-vacancy states with nl up to 5f. The accuracy of the calculated level energies is established by comparison with the recommended data listed in the National Institute of Standards and Technology (NIST) online database. The average deviation of valence level energies ranges from 0.20eV in SiV to 0.04eV in SiXII. For K-vacancy states, the available values recommended in the NIST database are limited to Si XII and Si XIII. The average energy deviation is below 0.3eV for K-vacancy states. The extensive and accurate data set presented here greatly augments the amount of available reference level energies. We expect our data to ease the line identification of L-shell ions of Si in celestial sources and laboratory-generated plasmas, and to serve as energy references in the absence of more accurate laboratory measurements. (1 data file).
Relativistic MR–MP Energy Levels for L-shell Ions of Silicon
DOE Office of Scientific and Technical Information (OSTI.GOV)
Santana, Juan A.; Lopez-Dauphin, Nahyr A.; Beiersdorfer, Peter
Level energies are reported for Si v, Si vi, Si vii, Si viii, Si ix, Si x, Si xi, and Si xii. The energies have been calculated with the relativistic Multi-Reference Møller–Plesset Perturbation Theory method and include valence and K-vacancy states with nl up to 5f. The accuracy of the calculated level energies is established by comparison with the recommended data listed in the National Institute of Standards and Technology (NIST) online database. The average deviation of valence level energies ranges from 0.20 eV in Si v to 0.04 eV in Si xii. For K-vacancy states, the available values recommendedmore » in the NIST database are limited to Si xii and Si xiii. The average energy deviation is below 0.3 eV for K-vacancy states. The extensive and accurate data set presented here greatly augments the amount of available reference level energies. Here, we expect our data to ease the line identification of L-shell ions of Si in celestial sources and laboratory-generated plasmas, and to serve as energy references in the absence of more accurate laboratory measurements.« less
A teaching intervention for reading laboratory experiments in college-level introductory chemistry
NASA Astrophysics Data System (ADS)
Kirk, Maria Kristine
The purpose of this study was to determine the effects that a pre-laboratory guide, conceptualized as a "scientific story grammar," has on college chemistry students' learning when they read an introductory chemistry laboratory manual and perform the experiments in the chemistry laboratory. The participants (N = 56) were students enrolled in four existing general chemistry laboratory sections taught by two instructors at a women's liberal arts college. The pre-laboratory guide consisted of eight questions about the experiment, including the purpose, chemical species, variables, chemical method, procedure, and hypothesis. The effects of the intervention were compared with those of the traditional pre-laboratory assignment for the eight chemistry experiments. Measures included quizzes, tests, chemistry achievement test, science process skills test, laboratory reports, laboratory average, and semester grade. The covariates were mathematical aptitude and prior knowledge of chemistry and science processes, on which the groups differed significantly. The study captured students' perceptions of their experience in general chemistry through a survey and interviews with eight students. The only significant differences in the treatment group's performance were in some subscores on lecture items and laboratory items on the quizzes. An apparent induction period was noted, in that significant measures occurred in mid-semester. Voluntary study with the pre-laboratory guide by control students precluded significant differences on measures given later in the semester. The groups' responses to the survey were similar. Significant instructor effects on three survey items were corroborated by the interviews. The researcher's students were more positive about their pre-laboratory tasks, enjoyed the laboratory sessions more, and were more confident about doing chemistry experiments than the laboratory instructor's groups due to differences in scaffolding by the instructors.
Ghosh Hajra, Sujoy; Liu, Careesa C; Song, Xiaowei; Fickling, Shaun D; Cheung, Teresa P L; D'Arcy, Ryan C N
2018-06-04
For nearly four decades, the N400 has been an important brainwave marker of semantic processing. It can be recorded non-invasively from the scalp using electrical and/or magnetic sensors, but largely within the restricted domain of research laboratories specialized to run specific N400 experiments. However, there is increasing evidence of significant clinical utility for the N400 in neurological evaluation, particularly at the individual level. To enable clinical applications, we recently reported a rapid evaluation framework known as "brain vital signs" that successfully incorporated the N400 response as one of the core components for cognitive function evaluation. The current study characterized the rapidly evoked N400 response to demonstrate that it shares consistent features with traditional N400 responses acquired in research laboratory settings-thereby enabling its translation into brain vital signs applications. Data were collected from 17 healthy individuals using magnetoencephalography (MEG) and electroencephalography (EEG), with analysis of sensor-level effects as well as evaluation of brain sources. Individual-level N400 responses were classified using machine learning to determine the percentage of participants in whom the response was successfully detected. The N400 response was observed in both M/EEG modalities showing significant differences to incongruent versus congruent condition in the expected time range (p < 0.05). Also as expected, N400-related brain activity was observed in the temporal and inferior frontal cortical regions, with typical left-hemispheric asymmetry. Classification robustly confirmed the N400 effect at the individual level with high accuracy (89%), sensitivity (0.88) and specificity (0.90). The brain vital sign N400 characteristics were highly consistent with features of the previously reported N400 responses acquired using traditional laboratory-based experiments. These results provide important evidence supporting clinical translation of the rapidly acquired N400 response as a potential tool for assessments of higher cognitive functions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martha R. Finck Ph.D.
2011-10-01
This program provides practical training to DHS graduate fellows in the DOE laboratory complex. It involves coordinating students, their thesis advisors, and their laboratory project mentors in establishing a meaningful program of research which contributes to the graduate student's formation as a member of the nuclear forensics community. The summary report details the student/mentor experience and future plans after the first summer practicum. This program provides practical training to DHS graduate fellows in the DOE laboratory complex. It involves coordinating students, their thesis advisors, and their laboratory project mentors in establishing a meaningful program of research which contributes to themore » graduate student's formation as a member of the nuclear forensics community. This final written report includes information concerning the overall mentoring experience, including benefits (to the lab, the mentors, and the students), challenges, student research contributions, and lab mentor interactions with students home universities. Idaho National Laboratory hosted two DHS Nuclear Forensics graduate Fellows (nuclear engineering) in summer 2011. Two more Fellows (radiochemistry) are expected to conduct research at the INL under this program starting in 2012. An undergraduate Fellow (nuclear engineering) who worked in summer 2011 at the laboratory is keenly interested in applying for the NF Graduate Fellowship this winter with the aim of returning to INL. In summary, this program appears to have great potential for success in supporting graduate level students who pursue careers in nuclear forensics. This relatively specialized field may not have been an obvious choice for some who have already shown talent in the traditional areas of chemistry or nuclear engineering. The active recruiting for this scholarship program for candidates at universities across the U.S. brings needed visibility to this field. Not only does this program offer critical practical training to these students, it brings attention to a very attractive field of work where young professionals are urgently required in order for the future. The effectiveness of retaining such talent remains to be seen and may be primarily controlled by the availability of DOE laboratory research funding in this field in the years to come.« less
Salinas, Maria; López-Garrigós, Maite; Gutiérrez, Mercedes; Lugo, Javier; Sirvent, Jose Vicente; Uris, Joaquin
2010-01-01
Laboratory performance can be measured using a set of model key performance indicators (KPIs). The design and implementation of KPIs are important issues. KPI results from 7 years are reported and their implementation, monitoring, objectives, interventions, result reporting and delivery are analyzed. The KPIs of the entire laboratory process were obtained using Laboratory Information System (LIS) registers. These were collected automatically using a data warehouse application, spreadsheets and external quality program reports. Customer satisfaction was assessed using surveys. Nine model laboratory KPIs were proposed and measured. The results of some examples of KPIs used in our laboratory are reported. Their corrective measurements or the implementation of objectives led to improvement in the associated KPIs results. Measurement of laboratory performance using KPIs and a data warehouse application that continuously collects registers and calculates KPIs confirmed the reliability of indicators, indicator acceptability and usability for users, and continuous process improvement.
Idaho National Laboratory Quarterly Event Performance Analysis FY 2013 4th Quarter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mitchell, Lisbeth A.
2013-11-01
This report is published quarterly by the Idaho National Laboratory (INL) Performance Assurance Organization. The Department of Energy Occurrence Reporting and Processing System (ORPS) as prescribed in DOE Order 232.2 “Occurrence Reporting and Processing of Operations Information” requires a quarterly analysis of events, both reportable and not reportable for the previous twelve months. This report is the analysis of occurrence reports and deficiency reports (including not reportable events) identified at the Idaho National Laboratory (INL) during the period of October 2012 through September 2013.
Roisman, Glenn I; Clausell, Eric; Holland, Ashley; Fortuna, Keren; Elieff, Chryle
2008-01-01
This article presents a multimethod, multi-informant comparison of community samples of committed gay male (n=30) and lesbian (n=30) couples with both committed (n=50 young engaged and n=40 older married) and noncommitted (n=109 exclusively dating) heterosexual pairs. Specifically, in this study the quality of same- and opposite-sex relationships was examined at multiple levels of analysis via self-reports and partner reports, laboratory observations, and measures of physiological reactivity during dyadic interactions. Additionally, individuals in same-sex, engaged, and marital relationships were compared with one another on adult attachment security as assessed through the coherence of participants' narratives about their childhood experiences. Results indicated that individuals in committed same-sex relationships were generally not distinguishable from their committed heterosexual counterparts, with one exception--lesbians were especially effective at working together harmoniously in laboratory observations. Copyright (c) 2008 APA.
Bioremediation of aircraft deicing fluids (glycol) at airports. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gallagher, D.W.
1998-09-01
This report describes the work done to determine the effectiveness of various aerobic bioremediation techniques for reducing the biochemical oxygen demand (BOD) of aircraft deicing fluid runoff. Primary emphasis has been placed on laboratory and field demonstrations of bioremediation systems using various combinations of inocula (bacteria), nutrient mixes, enzyme mixes, and ultrasonic stimulation. Laboratory experiments with a variety of inocula and nutrients together with enzymes and ultrasound are demonstrated showing the importance of the appropriate bacteria and nutrient mix in bioaugmentation. The appropriate mix was shown to significantly influence biodegradation. Deicing solutions were routinely reduced to acceptable BOD levels formore » effluent discharge in 3 days or less. In the field experiment, a special dual-tank bioreactor system was developed to demonstrate a pilot small-scale system. Experimental operation of this system confirmed that a 3-day or less remediation cycle was possible during the winter season.« less
Frey, Jodi Jacobson; Osteen, Philip J; Berglund, Patricia A; Jinnett, Kimberly; Ko, Jungyai
2015-04-01
Examine associations of chronic health conditions on workplace productivity and accidents among US Department of Energy employees. The Health and Work Performance Questionnaire-Select was administered to a random sample of two Department of Energy national laboratory employees (46% response rate; N = 1854). The majority (87.4%) reported having one or more chronic health conditions, with 43.4% reporting four or more conditions. A population-attributable risk proportions analysis suggests improvements of 4.5% in absenteeism, 5.1% in presenteeism, 8.9% in productivity, and 77% of accidents by reducing the number of conditions by one level. Depression was the only health condition associated with all four outcomes. Results suggest that chronic conditions in this workforce are prevalent and costly. Efforts to prevent or reduce condition comorbidity among employees with multiple conditions can significantly reduce costs and workplace accident rates.
Identification of the students' critical thinking skills through biochemistry laboratory work report
NASA Astrophysics Data System (ADS)
Anwar, Yunita Arian Sani; Senam, Laksono, Endang W.
2017-08-01
This work aims to (1) identify the critical thinking skills of student based on their ability to set up laboratory work reports, and (2) analyze the implementation of biochemistry laboratory work. The method of quantitative content analysis was employed. Quantitative data were in the form of critical thinking skills through the assessment of students' laboratory work reports and questionnaire data. Hoyo rubric was used to measure critical thinking skills with 10 indicators, namely clarity, accuracy, precision, consistency, relevance, evidence, reason, depth, breadth, and fairness. The research sample consisted of 105 students (35 male, 70 female) of Mataram University who took a Biochemistry course and 2 lecturers of Biochemistry course. The results showed students' critical thinking skills through laboratory work reports were still weak. Analysis of the questionnaire showed that three indicators become the biggest problems during the laboratory work implementation, namely, lecturers' involved in laboratory work implementation, the integration of laboratory work implementation of learning in the classroom has not been done optimally and laboratory work implementation as an effort to train critical thinking skills is not optimal yet.
Ahrari, Shahnaz; Moshki, Mahdi; Bahrami, Mahnaz
2014-01-01
Introduction: Patient's noncompliance dietary and fluids intake can lead to a build-up of toxic fluids and metabolic end-products in the blood stream which may result in an increased morbidity and premature death. The aim of the study is investigate relationship between the social support and adherence to dietary and fluid restrictions in hemodialysis patients. Methods: In this correlational study upon 237 hemodialysis patients, the data was collected with the dialysis diet and fluids non-adherences hemodialysis questionnaire (DDFQ), and the multidimensional scale of perceived Social Support (MSP). Interdialytic weight gain, predialytic serum potassium levels, and predialytic serum phosphate levels was considered as biochemical indicators of dietary and fluid adherence. Data were analyzed by SPSS Ver.11.5. Results: About 41.1% of patients reported non-adherence to diet and 45.2% of them reported non-adherence to fluid. Frequency of non-adherence to fluid was more common in patients. The highest level of perceived support was the family support 11.19 (1.34). There was a significant relationship between social support and adherence to dietary and fluid restrictions. Noncompliances to dietary and fluid restrictions were related to laboratory results. Conclusion: This way those patients who more supported had more adherences of diet and fluid restrictions and had lower level of phosphorus and potassium in laboratory results. Nurses have the main role to identify different methods providing social support for patients, also to encourage the families to support their hemodialysis patients. PMID:25276744
Quadriplegia due to lead-contaminated opium--case report.
Beigmohammadi, Mohammad Taghi; Aghdashi, Moosa; Najafi, Atabak; Mojtahedzadeh, Mojtaba; Karvandian, Kassra
2008-10-01
Utilization of lead-contaminated opium may lead to severe motor neuron impairment and quadriplegia. Forty years oriented old male, opium addict, was admitted to the ICU, with headache, nausea and abdominal pain, and weakness in his lower and upper extremities without definitive diagnosis. The past medical and occupational history was negative. Laboratory investigation showed; anemia (Hb 7.7 g/dl), slightly elevated liver function tests, elevated total bilirubin, and ESR. Abdominal sonography and brain CT scan were normal. EMG and NCV results and neurologic examination were suggestive for Guillain-Barre. He underwent five sessions of plasmapheresis. Blood lead level was > 200 microg/dl. He received dimercaprol (BAL) and calcium disodium edetate (CaEDTA) for two five days session. Upon discharge from ICU all laboratory tests were normal and blood lead level was reduced, but he was quadriplegic. The delayed treatment of lead poisoning may lead to irreversible motor neuron defect.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This purpose of this report is to summarize the activities of the Analytical Chemistry Laboratory (ACL) at Argonne National Laboratory (ANL) for Fiscal Year 1990. The ACL has four technical groups -- Chemical Analysis, Instrumental Analysis, Organic Analysis, and Environmental Analysis. The Chemical Analysis Group uses wet-chemical and instrumental methods for elemental, compositional, and isotopic analyses of solid, liquid, and gaseous samples and provides specialized analytical services. The Instrumental Analysis Group uses nuclear counting techniques in radiochemical analyses over a wide range of sample types from low-level environmental samples to samples of high radioactivity. The Organic Analysis Group uses amore » number of complementary techniques to separate and to quantitatively and qualitatively analyze complex organic mixtures and compounds at the trace level, including synthetic fuels, toxic substances, fossil-fuel residues and emissions, pollutants, biologically active compounds, pesticides, and drugs. The Environmental Analysis Group performs analyses of inorganic environmental and hazardous waste and coal samples.« less
Clinical and laboratory factors associated with mortality in dengue.
Saroch, Atul; Arya, Vivek; Sinha, Nitin; Taneja, R S; Sahai, Pooja; Mahajan, R K
2017-04-01
Dengue is endemic in more than 100 countries, giving rise to an increased number of deaths in the last five years in the South-East Asian region. We report our findings from a retrospective study of adults admitted with confirmed dengue at our institution. We studied the clinical and laboratory parameters associated with mortality in these patients. Of the 172 hospitalised patients studied, 156 (90.69 %) recovered while 16 (9.3%) died. Univariate analysis showed altered sensorium on presentation, lower haemoglobin and haematocrit levels, higher serum creatinine, higher serum transaminase and lower serum albumin levels to be significantly associated with mortality in dengue. Further, using stepwise multivariate logistic regression, altered sensorium ( P = 0.006) and hypoalbuminemia ( P = 0.013) were identified as independent predictors of mortality in dengue. Identification of these parameters early in the course of disease should prompt intensification of treatment in dengue cases.
Evaluating performance in sweat testing in medical biochemistry laboratories in Croatia.
Aralica, Merica; Krleza, Jasna Lenicek
2017-02-15
Sweat test has a diagnostic role in evaluation of cystic fibrosis. Its performance includes sweat stimulation, collection and analysis. All listed may be sources of inconsistencies in everyday practice. The aim of this study was an evaluation of external quality assessment (EQA) of sweat chloride measurement including sweat test performance in medical biochemistry laboratories in Croatia. EQA for sweat chloride measurement was provided by Croatian Centre for Quality Assessment in Laboratory Medicine (CROQALM) in five consecutive exercises to medical biochemistry laboratories (MBL) that offered sweat testing. A questionnaire regarding all phases of testing was mailed to involved MBL (N = 10). Survey results were compared to current guidelines for sweat test performance. Reported results of EQA in 2015 exercises showed coefficients of variation (CV) from 28.9%, 29.0% to 35.3%, respectively. An introduction of uniform sweat chloride measurement protocol resulted in CV of 15.5% and 14.7% reported in following two exercises in 2016. All MBL included in this study replied to the questionnaire. Results reported by MBL indicated: lack of patient information policy (7/10), use of unacceptable electrodes (6/9), misuse of minimum of acceptable sweat weight (6/9), lack of internal quality assessment (5/9) and recommended reference ranges (5/9 and 4/9). Agreements to guidelines were found in approach to unsuitable patients (9/10) and sweat collection (8/9). Presented results indicate major weak points of current practice in sweat test performance in Croatian MBL and stress the need for its standardization on a national level.
Evaluating performance in sweat testing in medical biochemistry laboratories in Croatia
Aralica, Merica; Krleza, Jasna Lenicek
2017-01-01
Introduction Sweat test has a diagnostic role in evaluation of cystic fibrosis. Its performance includes sweat stimulation, collection and analysis. All listed may be sources of inconsistencies in everyday practice. The aim of this study was an evaluation of external quality assessment (EQA) of sweat chloride measurement including sweat test performance in medical biochemistry laboratories in Croatia. Materials and methods EQA for sweat chloride measurement was provided by Croatian Centre for Quality Assessment in Laboratory Medicine (CROQALM) in five consecutive exercises to medical biochemistry laboratories (MBL) that offered sweat testing. A questionnaire regarding all phases of testing was mailed to involved MBL (N = 10). Survey results were compared to current guidelines for sweat test performance. Results Reported results of EQA in 2015 exercises showed coefficients of variation (CV) from 28.9%, 29.0% to 35.3%, respectively. An introduction of uniform sweat chloride measurement protocol resulted in CV of 15.5% and 14.7% reported in following two exercises in 2016. All MBL included in this study replied to the questionnaire. Results reported by MBL indicated: lack of patient information policy (7/10), use of unacceptable electrodes (6/9), misuse of minimum of acceptable sweat weight (6/9), lack of internal quality assessment (5/9) and recommended reference ranges (5/9 and 4/9). Agreements to guidelines were found in approach to unsuitable patients (9/10) and sweat collection (8/9). Conclusion Presented results indicate major weak points of current practice in sweat test performance in Croatian MBL and stress the need for its standardization on a national level. PMID:28392735
Publications - DGGS Publications Series | Alaska Division of Geological &
Report IC - Information Circular IR - Itinerary Report LN - Laboratory Notes LR - Laboratory Report MI . IR - Itinerary Report This series includes reports produced by the Territorial Department of Mines
2011 Annual Report (National Defense Center for Energy and Environment)
2011-01-01
scale or laboratory testing. Green Automated Munitions Evaluation and Recovery System (GAMERS) Cadmium and Hexavalent Chromium Free Electrical...internal cavities and enhancing oxidation removal and prevention. While sustainable alternatives to cadmium and chromium continue to be evaluated...Letterkenny Army Depot (LEAD) teamed with the NDCEE to reduce cadmium levels in process wastewater and ensure compliance with the depot’s discharge
ERIC Educational Resources Information Center
Novick, Laura R.; Catley, Kefyn M.
2018-01-01
The ability to interpret and reason from Tree of Life diagrams is a key component of twenty-first century science literacy. This article reports on the authors' continued development of a multifaceted research-based curriculum--including an instructional booklet, lectures, laboratories and a field activity--to teach such tree thinking to biology…
Persistent hypoglycemia of unknown etiology in a patient without diabetes: a case report and review.
White, Bryan P; Southwood, Robin
2013-04-01
This case report reviews the presentation, evaluation, and treatment of persistent hypoglycemia in a patient without a history of diabetes. The use of laboratory tests to differentiate between drug-induced and disease-induced hypoglycemia is reviewed. A 51-year-old female with multiple medical conditions including bipolar disorder and no history of diabetes was admitted for evaluation and treatment of hypoglycemia. Pharmacotherapy included intravenous dextrose infusions and bolus doses. A battery of tests was ordered to evaluate intrinsic and extrinsic causes. Endocrine Society guidelines for hypoglycemia exist and have recommendations for testing and strategies to rule out drug-related causes. Her insulin level was 57 IU/mL (normal range < 17). Her proinsulin level was 356.8 pmol/L (normal range <8.8). The guidelines recommend a battery of laboratory tests; however, the results are not rapidly available necessitating a structured follow-up process. In our patient, exposure to hypoglycemic agents and exogenous insulin can be ruled out. Autoimmune hypoglycemia or a hypoglycemic reaction to one of her home medications is very unlikely, but cannot be ruled out. An insulinoma is the most likely etiology of her hypoglycemia, but that cannot be confirmed.
Zhen-Yu, Wang; Li, Jiang; Yao-Guang, Zhang; Min, Zhu; Xiao-Ping, Zhang; Xiao-Jiang, Ma; Qian, Zhu; Yan-Yan, He; Shou-Fu, Jiang; Li, Cai
2017-02-27
To compare the application effects of three methods, namely microscopic examination, antigen detection (RDT) and nucleic acid test (PCR) in malaria detection between municipal and districts/counties centers for disease control and prevention in Shanghai, and analyze the malaria detection ability of the laboratories in Shanghai. The blood smears, whole blood samples, case review confirmation records and case data of malaria cases and suspected cases in Shanghai from 2012 to 2015 were collected by Shanghai Municipal Center for Disease Control and Prevention, and the detection results were analyzed and compared. A total of 212 samples with complete data were submitted by all districts (counties) in Shanghai from 2012 to 2015, the samples submitted by Jinshan Districts were the most (41.98%), and among the first diagnosis hospitals, those submitted by the tertiary hospitals were the most (82.07%). The submitted samples in the whole year were increased gradually from January to October. All the 212 samples were detected by three methods (the microscopic examination, RDT and PCR) in the laboratory of Shanghai Municipal Center for Disease Control and Prevention, and 167 were tested and confirmed comprehensively as positives, accounting for 78.77%, and 45 were confirmed as negatives, accounting for 21.23%. The samples were detected by the method of microscopy and domestic RDT in the laboratories of the centers for disease control and prevention at district/county level, totally 153 were tested as positives, accounting for 72.17%, 41 were unclassified, accounting for 19.34%, 53 were negative, accounting for 25.00%, and 6 were undetected, accounting for 2.83%. The coincidence of microscopic examination between the report hospitals and the centers for disease control and prevention at district/county level was 78.16%, and the coincidence between centers for disease control and prevention at district/county level and municipal level was 93.20%. The utilization rate of RDT in the laboratory of district/county level was 73.58%. The coincidence of RDT tests between those domestic and imported was 93.59%. Compared with the detection results by municipal center for disease control and prevention, 37 samples were misjudged by the laboratories of district/county level. Almost all (99.37%) of the confirmed malaria cases were imported overseas, including Africa (85.44%), Asia (13.92%) and America (0.63%). The surveillance after malaria elimination in Shanghai should be carried out by combining with different detection methods and resource integration.
Quality in the molecular microbiology laboratory.
Wallace, Paul S; MacKay, William G
2013-01-01
In the clinical microbiology laboratory advances in nucleic acid detection, quantification, and sequence analysis have led to considerable improvements in the diagnosis, management, and monitoring of infectious diseases. Molecular diagnostic methods are routinely used to make clinical decisions based on when and how to treat a patient as well as monitor the effectiveness of a therapeutic regime and identify any potential drug resistant strains that may impact on the long term patient treatment program. Therefore, confidence in the reliability of the result provided by the laboratory service to the clinician is essential for patient treatment. Hence, suitable quality assurance and quality control measures are important to ensure that the laboratory methods and service meet the necessary regulatory requirements both at the national and international level. In essence, the modern clinical microbiology laboratory ensures the appropriateness of its services through a quality management system that monitors all aspects of the laboratory service pre- and post-analytical-from patient sample receipt to reporting of results, from checking and upholding staff competency within the laboratory to identifying areas for quality improvements within the service offered. For most European based clinical microbiology laboratories this means following the common International Standard Organization (ISO9001) framework and ISO15189 which sets out the quality management requirements for the medical laboratory (BS EN ISO 15189 (2003) Medical laboratories-particular requirements for quality and competence. British Standards Institute, Bristol, UK). In the United States clinical laboratories performing human diagnostic tests are regulated by the Centers for Medicare and Medicaid Services (CMS) following the requirements within the Clinical Laboratory Improvement Amendments document 1988 (CLIA-88). This chapter focuses on the key quality assurance and quality control requirements within the modern microbiology laboratory providing molecular diagnostics.
Stackelberg, Paul E.; Furlong, Edward T.; Meyer, Michael T.; Zaugg, Steven D.; Henderson, Alden K.; Reissman, Dori B.
2006-01-01
The U.S. Geological Survey (USGS) and the Centers for Disease Control thank Dr. Till for her comments concerning our research (Till, 2005) and welcome the opportunity to respond. The primary objective of our study was to evaluate the potential for organic wastewater-related contaminants (OWCs), including pharmaceuticals, to survive a conventional drinking-water-treatment process and persist in potable-water supplies (Stackelberg et al., 2004). Our study was supported by two USGS laboratories: the National Water Quality Laboratory (NWQL), which provided the HPLC/ESI-MS and CLLE GC/MS data and the Ocala Water Quality and Research Laboratory (OWQRL), which provided the LC/MS data (Stackelberg et al., 2004). Although discussed as distinct techniques by Dr. Till and indicated by differing acronyms to distinguish the laboratories producing the data, as described in our paper, the two LC/MS methods are very similar; they consist of a solid-phase extraction method with analysis of the extract produced using high-performance liquid chromatography coupled to an electrospray ionization mass spectrometer operated in the positive mode. The NWQL and OWQRL report ‘trace’ and ‘ultratrace’ determinations of analytes that provide significant benefit for describing the presence and fate of low-level contaminants. For mass spectral methods, an analyte is qualitatively identified by its retention time on the chromatographic column as well as the presence of two or more confirming ions with area ratios that match that of the reference standard compounds. Because of a recognized increased risk of false positives, these qualitative identification criteria are used in conjunction with abundant quality-control samples (detailed below) to confirm detection prior to making an estimate of the concentration. These qualitative identification criteria must be met before a compound is considered present (or detected) in a sample (Oblinger Childress et al., 1999). When a compound has been qualitatively identified in an environmental sample (whether above or below its reporting level [RL]), it is assessed in context with associated field and laboratory blanks, field and laboratory replicates, and other data, such as appropriate laboratory reagent spikes. An environmental concentration is calculated only after determining that field and laboratory procedures did not contaminate the samples. The concentrations are then calculated from 5- to 8-point calibration curves using internal standard quantitation. Our lowest calibration standard is intentionally much lower than the RL, typically 10 times lower. The most abundant molecular or fragment ion is used for quantitation, and, for the two LC/MS methods, at least one, and where possible two, qualifier ions are used for confirmation. For the GC/MS method, with its greater degree of fragmentation, one quantitation and two qualifier ions are used. When any of the abovementioned qualitative identification criteria are not met, the analyte is considered not present and is reported as “less than” the RL.
Background Radioactivity in River and Reservoir Sediments near Los Alamos, New Mexico
DOE Office of Scientific and Technical Information (OSTI.GOV)
S.G.McLin; D.W. Lyons
2002-05-05
As part of its continuing Environmental Surveillance Program, regional river and lake-bottom sediments have been collected annually by Los Alamos National Laboratory (the Laboratory) since 1974 and 1979, respectively. These background samples are collected from three drainage basins at ten different river stations and five reservoirs located throughout northern New Mexico and southern Colorado. Radiochemical analyses for these sediments include tritium, strontium-90, cesium-137, total uranium, plutonium-238, plutonium-239,-240, americium-241, gross alpha, gross beta, and gross gamma radioactivity. Detection-limit radioactivity originates as worldwide fallout from aboveground nuclear weapons testing and satellite reentry into Earth's atmosphere. Spatial and temporal variations in individual analytemore » levels originate from atmospheric point-source introductions and natural rate differences in airborne deposition and soil erosion. Background radioactivity values on sediments reflect this variability, and grouped river and reservoir sediment samples show a range of statistical distributions that appear to be analyte dependent. Traditionally, both river and reservoir analyte data were blended together to establish background levels. In this report, however, we group background sediment data according to two criteria. These include sediment source (either river or reservoir sediments) and station location relative to the Laboratory (either upstream or downstream). These grouped data are statistically evaluated through 1997, and background radioactivity values are established for individual analytes in upstream river and reservoir sediments. This information may be used to establish the existence and areal extent of trace-level environmental contamination resulting from historical Laboratory research activities since the early 1940s.« less
NASA Astrophysics Data System (ADS)
Scharfenberg, Franz-Josef; Bogner, Franz X.
2013-02-01
This study classified students into different cognitive load (CL) groups by means of cluster analysis based on their experienced CL in a gene technology outreach lab which has instructionally been designed with regard to CL theory. The relationships of the identified student CL clusters to learner characteristics, laboratory variables, and cognitive achievement were examined using a pre-post-follow-up design. Participants of our day-long module Genetic Fingerprinting were 409 twelfth-graders. During the module instructional phases (pre-lab, theoretical, experimental, and interpretation phases), we measured the students' mental effort (ME) as an index of CL. By clustering the students' module-phase-specific ME pattern, we found three student CL clusters which were independent of the module instructional phases, labeled as low-level, average-level, and high-level loaded clusters. Additionally, we found two student CL clusters that were each particular to a specific module phase. Their members reported especially high ME invested in one phase each: within the pre-lab phase and within the interpretation phase. Differentiating the clusters, we identified uncertainty tolerance, prior experience in experimentation, epistemic interest, and prior knowledge as relevant learner characteristics. We found relationships to cognitive achievement, but no relationships to the examined laboratory variables. Our results underscore the importance of pre-lab and interpretation phases in hands-on teaching in science education and the need for teachers to pay attention to these phases, both inside and outside of outreach laboratory learning settings.
Online Assessment of Learning and Engagement in University Laboratory Practicals
ERIC Educational Resources Information Center
Whitworth, David E.; Wright, Kate
2015-01-01
In science education, laboratory practicals are frequently assessed through submission of a report. A large increase in student numbers necessitated us adapting a traditional practical report into an online test with automated marking. The assessment was designed to retain positive features of the traditional laboratory report but with added…
Ding, Zhiping; Wen, Yucong; Yang, Baojun; Zhang, Yixi; Liu, Shuhua; Liu, Zewen; Han, Zhaojun
2013-11-01
Imidacloprid is a key insecticide extensively used for control of Nilaparvata lugens, and its resistance had been reported both in the laboratory selected strains and field populations. A target site mutation Y151S in two nicotinic acetylcholine receptor subunits and enhanced oxidative detoxification have been identified in the laboratory resistant strain, contributing importantly to imidacloprid resistance in N. lugens. To date, however, imidacloprid resistance in field population is primarily attributable to enhanced oxidative detoxification by over-expressed P450 monooxygenases. A resistant strain (Res), originally collected from a field population and continuously selected in laboratory with imidacloprid for more than 40 generations, had 180.8-fold resistance to imidacloprid, compared to a susceptible strain (Sus). Expression of different putative P450 genes at mRNA levels was detected and compared between Res and Sus strains, and six genes were found expressed significantly higher in Res strain than in Sus strain. CYP6AY1 was found to be the most different expressed P450 gene and its mRNA level in Res strain was 17.9 times of that in Sus strain. By expressing in E. coli cells, CYP6AY1 was found to metabolize imidacloprid efficiently with initial velocity calculated of 0.851 ± 0.073 pmol/min/pmol P450. When CYP6AY1 mRNA levels in Res strain was reduced by RNA interference, imidacloprid susceptibility was recovered. In four field populations with different resistance levels, high levels of CYP6AY1 transcript were also found. In vitro and in vivo studies provided evidences that the over-expression of CYP6AY1 was one of the key factors contributing to imidacloprid resistance in the laboratory selected strain Res, which might also be the important mechanism for imidacloprid resistance in field populations, when the target site mutation was not prevalent at present. Copyright © 2013 Elsevier Ltd. All rights reserved.
Winslow, Stephen D; Pepich, Barry V; Martin, John J; Hallberg, George R; Munch, David J; Frebis, Christopher P; Hedrick, Elizabeth J; Krop, Richard A
2006-01-01
The United States Environmental Protection Agency's Office of Ground Water and Drinking Water has developed a single-laboratory quantitation procedure: the lowest concentration minimum reporting level (LCMRL). The LCMRL is the lowest true concentration for which future recovery is predicted to fall, with high confidence (99%), between 50% and 150%. The procedure takes into account precision and accuracy. Multiple concentration replicates are processed through the entire analytical method and the data are plotted as measured sample concentration (y-axis) versus true concentration (x-axis). If the data support an assumption of constant variance over the concentration range, an ordinary least-squares regression line is drawn; otherwise, a variance-weighted least-squares regression is used. Prediction interval lines of 99% confidence are drawn about the regression. At the points where the prediction interval lines intersect with data quality objective lines of 50% and 150% recovery, lines are dropped to the x-axis. The higher of the two values is the LCMRL. The LCMRL procedure is flexible because the data quality objectives (50-150%) and the prediction interval confidence (99%) can be varied to suit program needs. The LCMRL determination is performed during method development only. A simpler procedure for verification of data quality objectives at a given minimum reporting level (MRL) is also presented. The verification procedure requires a single set of seven samples taken through the entire method procedure. If the calculated prediction interval is contained within data quality recovery limits (50-150%), the laboratory performance at the MRL is verified.
Perceptions of Competence of Three Levels of Medical Laboratory Personnel.
ERIC Educational Resources Information Center
Davis, Judith A.
Commonalities and differences in the perception of competence among three levels of medical laboratory personnel were assessed through a survey of 100 educators, chief technologists, and working technicians. Respondents rated medical technologists (MTs), medical laboratory technicians (MLTs), and certified laboratory assistants (CLAs) on 270 tasks…
Cordeiro, F.; Llorente-Mirandes, T.; López-Sánchez, J.F.; Rubio, R.; Sánchez Agullo, A.; Raber, G.; Scharf, H.; Vélez, D.; Devesa, V.; Fiamegos, Y.; Emteborg, H.; Seghers, J.; Robouch, P.; de la Calle, M.B.
2015-01-01
The Institute for Reference Materials and Measurements (IRMM) of the Joint Research Centre (JRC), a Directorate General of the European Commission, operates the International Measurement Evaluation Program (IMEP). IMEP organises inter-laboratory comparisons in support of European Union policies. This paper presents the results of two proficiency tests (PTs): IMEP-116 and IMEP-39, organised for the determination of total Cd, Pb, As, Hg and inorganic As (iAs) in mushrooms. Participation in IMEP-116 was restricted to National Reference Laboratories (NRLs) officially appointed by national authorities in European Union member states. IMEP-39 was open to all other laboratories wishing to participate. Thirty-seven participants from 25 countries reported results in IMEP-116, and 62 laboratories from 36 countries reported for the IMEP-39 study. Both PTs were organised in support to Regulation (EC) No. 1881/2006, which sets the maximum levels for certain contaminants in food. The test item used in both PTs was a blend of mushrooms of the variety shiitake (Lentinula edodes). Five laboratories, with demonstrated measurement capability in the field, provided results to establish the assigned values (X ref). The standard uncertainties associated to the assigned values (u ref) were calculated by combining the uncertainty of the characterisation (u char) with a contribution for homogeneity (u bb) and for stability (u st), whilst u char was calculated following ISO 13528. Laboratory results were rated with z- and zeta (ζ)-scores in accordance with ISO 13528. The standard deviation for proficiency assessment, σ p, ranged from 10% to 20% depending on the analyte. The percentage of satisfactory z-scores ranged from 81% (iAs) to 97% (total Cd) in IMEP-116 and from 64% (iAs) to 84% (total Hg) in IMEP-39. PMID:25365736
Awareness and Knowledge of Ergonomics Among Medical Laboratory Scientists in Nigeria
Oladeinde, BH; Ekejindu, IM; Omoregie, R; Aguh, OD
2015-01-01
Background: Ergonomics awareness helps in its right application and contributes significantly to general wellbeing and safety of worker at workplace. Aim: This cross-sectional descriptive study aimed at assessing the level of awareness and knowledge of the science of ergonomics among Medical Laboratory Scientists in Benin City, Nigeria. Subjects and Methods: A total of 106 medical laboratory scientists comprising 64 and 42 in public and private laboratories, respectively, were recruited for this study using systematic random sampling technique. Data were obtained from the study participants using a questionnaire and subsequently analyzed with the statistical software INSTAT®. Results: Out of 106 study participants, 27 (25.5%) were reported to have heard of the term ergonomics. Awareness was significantly associated with gender (male vs. female: 38.5% [15/39] vs. 17.9% [12/67]; odds ratio = 2.9; 95% confidence interval = 1.2, 7.1;P = 0.02). Awareness of ergonomics was not significantly affected by affiliation (P = 0.18), area of specialization (P = 0.78), post-qualification experience (P = 0.43), and educational qualification (P = 0.23) of the study participants. Irrespective of the affiliation of the participant, only 6 of 27 (22.2%) participants who were aware of ergonomics knew at least a benefit of right application of ergonomics in the laboratory. Knowledge of risk factors for the development of musculoskeletal disorders was reported by 8 of 27 (29.6%) persons who claimed to be aware of ergonomics. Conclusions: Awareness of ergonomics and knowledge of gains of its right application was poor among the study participants. Regular ergonomic education of medical laboratory scientists in Nigeria is advocated. PMID:27057381
Cordeiro, F; Llorente-Mirandes, T; López-Sánchez, J F; Rubio, R; Sánchez Agullo, A; Raber, G; Scharf, H; Vélez, D; Devesa, V; Fiamegos, Y; Emteborg, H; Seghers, J; Robouch, P; de la Calle, M B
2015-01-01
The Institute for Reference Materials and Measurements (IRMM) of the Joint Research Centre (JRC), a Directorate General of the European Commission, operates the International Measurement Evaluation Program (IMEP). IMEP organises inter-laboratory comparisons in support of European Union policies. This paper presents the results of two proficiency tests (PTs): IMEP-116 and IMEP-39, organised for the determination of total Cd, Pb, As, Hg and inorganic As (iAs) in mushrooms. Participation in IMEP-116 was restricted to National Reference Laboratories (NRLs) officially appointed by national authorities in European Union member states. IMEP-39 was open to all other laboratories wishing to participate. Thirty-seven participants from 25 countries reported results in IMEP-116, and 62 laboratories from 36 countries reported for the IMEP-39 study. Both PTs were organised in support to Regulation (EC) No. 1881/2006, which sets the maximum levels for certain contaminants in food. The test item used in both PTs was a blend of mushrooms of the variety shiitake (Lentinula edodes). Five laboratories, with demonstrated measurement capability in the field, provided results to establish the assigned values (Xref). The standard uncertainties associated to the assigned values (uref) were calculated by combining the uncertainty of the characterisation (uchar) with a contribution for homogeneity (ubb) and for stability (ust), whilst uchar was calculated following ISO 13528. Laboratory results were rated with z- and zeta (ζ)-scores in accordance with ISO 13528. The standard deviation for proficiency assessment, σp, ranged from 10% to 20% depending on the analyte. The percentage of satisfactory z-scores ranged from 81% (iAs) to 97% (total Cd) in IMEP-116 and from 64% (iAs) to 84% (total Hg) in IMEP-39.
Ackerman, Sara L; Koenig, Barbara A
2018-01-01
Increasingly used for clinical purposes, genome and exome sequencing can generate clinically relevant information that is not directly related to the reason for testing (incidental or secondary findings). Debates about the ethical implications of secondary findings were sparked by the American College of Medical Genetics (ACMG) 2013 policy statement, which recommended that laboratories report pathogenic alterations in 56 genes. Although wide variation in laboratories' secondary findings policies has been reported, little is known about its causes. We interviewed 18 laboratory directors and genetic counselors at 10 U.S. laboratories to investigate the motivations and interests shaping secondary findings reporting policies for clinical exome sequencing. Analysis of interview transcripts and laboratory documents was informed by sociological theories of standardization. Laboratories varied widely in terms of the types of secondary findings reported, consent-form language, and choices offered to patients. In explaining their adaptation of the ACMG report, our participants weighed genetic information's clinical, moral, professional, and commercial value in an attempt to maximize benefits for patients and families, minimize the costs of sequencing and analysis, adhere to professional norms, attract customers, and contend with the uncertain clinical implications of much of the genetic information generated. Nearly all laboratories in our study voluntarily adopted ACMG's recommendations, but their actual practices varied considerably and were informed by laboratory-specific judgments about clinical utility and patient benefit. Our findings offer a compelling example of standardization as a complex process that rarely leads simply to uniformity of practice. As laboratories take on a more prominent role in decisions about the return of genetic information, strategies are needed to inform patients, families, and clinicians about the differences between laboratories' practices and ensure that the consent process prompts a discussion of the value of additional genetic information for patients and their families.
District, state or regional veterinary diagnostic laboratories.
Gosser, H S; Morehouse, L G
1998-08-01
The district, regional or state laboratory is the local laboratory to which veterinarian practitioners usually submit samples, and consequently these laboratories are usually the first to observe a suspected disease problem. In most countries, these laboratories are under the jurisdiction of the State or region in which they are located. In the United States of America (USA), most veterinary diagnostic laboratories are State-associated and operate under the aegis of either the State Department of Agriculture or a university. The national laboratory provides reference assistance to the State laboratories. In the USA, the national Laboratory (the National Veterinary Services Laboratories) acts as a consultant to confirm difficult diagnoses and administer performance tests for State-associated laboratories. District, state or regional laboratories need to share information regarding technological advances in diagnostic procedures. This need was met in the USA by the formation of the American Association of Veterinary Laboratory Diagnosticians (AAVLD) in the late 1950s. Another requirement of district, state or regional diagnostic laboratories is a method to confirm quality assurance, which was fulfilled in the USA by an accreditation programme established through the AAVLD. The Accreditation Committee evaluates laboratories (on request) in terms of organisation, personnel, physical facilities and equipment, records, finance and budget. Those laboratories which meet the standards as established in the 'Essential Requirements for Accreditation' are given accreditation status, which indicates that they have the expertise and facilities to perform tests on food-producing animals for shipment in national or international commerce and on companion, laboratory or zoo animals. While confidentiality of test records is most important, it is becoming necessary to release certain types of animal disease test information if a country is to participate in the exportation of animals and animal products. As district, state and regional laboratories operate under many different administrative entities (i.e., universities, State governments and the Federal government), various checks at different administrative levels provide safeguards and reduce the possibility of faulty disease reporting.
Wojciechowska-Mazurek, Maria; Starska, Krystyna; Mania, Monika; Brulińska-Ostrowska, Elzbieta; Biernat, Urszula; Karłowski, Kazimierz
2010-01-01
Results of the 5-years cycle (2004-2008) monitoring investigations on food contamination with elements noxious to human health, involving testing of mineral waters and soft drinks (226 samples), fruits (467 samples), rice (234 samples), soybeans (236 samples), nuts and peanuts (237 samples), fish and seafood (237 samples) are discussed. The parties involved in testing were: laboratories of State Sanitary Inspection and the national reference laboratory of the Department of Food and Consumer Articles Research of National Institute of Public Health - National Institute of Hygiene. The reported metals contents did not give rise to health concerns, remaining generally below the levels set forth in food legislation and being comparable with contamination levels reported in other European countries; and for cadmium--often lower. Health hazard assessment was performed taking into account the mean contamination levels obtained and average domestic consumption of these food products groups in Poland. The highest intake expressed as the percentage of provisional tolerable weekly intake (PTWI) was obtained for mercury in fish, which has reached mean 3.2% PTWI. Controlled fish consumption recommendations should be adhered to by prospective mothers, pregnant women, breast-feeding women and young children. Lead and arsenic intake with mineral waters and soft drinks comprises approx. 15% of total intake of these elements with food.
Monitoring of patients treated with lithium for bipolar disorder: an international survey.
Nederlof, M; Heerdink, E R; Egberts, A C G; Wilting, I; Stoker, L J; Hoekstra, R; Kupka, R W
2018-04-14
Adequate monitoring of patients using lithium is needed for optimal dosing and for early identification of patients with (potential) ADEs. The objective was to internationally assess how health care professionals monitor patients treated with lithium for bipolar disorder. Using networks of various professional organizations, an anonymous online survey was conducted among health care professionals prescribing lithium. Target lithium serum levels and frequency of monitoring was assessed together with monitoring of physical and laboratory parameters. Reasons to and not to monitor and use of guidelines and institutional protocols, and local monitoring systems were investigated. The survey was completed by 117 health care professionals incorporating responses from twenty-four countries. All prescribers reported to monitor lithium serum levels on a regular basis, with varying target ranges. Almost all (> 97%) monitored thyroid and renal function before start and during maintenance treatment. Reported monitoring of other laboratory and physical parameters was variable. The majority of respondents (74%) used guidelines or institutional protocols for monitoring. In general, the prescriber was responsible for monitoring, had to request every monitoring parameter separately and only a minority of patients was automatically invited. Lithium serum levels, renal and thyroid function were monitored by (almost) all physicians. However, there was considerable variation in other monitoring parameters. Our results help to understand why prescribers of lithium monitor patients and what their main reasons are not to monitor patients using lithium.
FY04 Engineering Technology Reports Laboratory Directed Research and Development
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharpe, R M
2005-01-27
This report summarizes the science and technology research and development efforts in Lawrence Livermore National Laboratory's Engineering Directorate for FY2004, and exemplifies Engineering's more than 50-year history of developing the technologies needed to support the Laboratory's missions. Engineering has been a partner in every major program and project at the Laboratory throughout its existence and has prepared for this role with a skilled workforce and the technical resources developed through venues like the Laboratory Directed Research and Development Program (LDRD). This accomplishment is well summarized by Engineering's mission: ''Enable program success today and ensure the Laboratory's vitality tomorrow''. Engineering's investmentmore » in technologies is carried out through two programs, the ''Tech Base'' program and the LDRD program. LDRD is the vehicle for creating those technologies and competencies that are cutting edge. These require a significant level of research or contain some unknown that needs to be fully understood. Tech Base is used to apply technologies to a Laboratory need. The term commonly used for Tech Base projects is ''reduction to practice''. Therefore, the LDRD report covered here has a strong research emphasis. Areas that are presented all fall into those needed to accomplish our mission. For FY2004, Engineering's LDRD projects were focused on mesoscale target fabrication and characterization, development of engineering computational capability, material studies and modeling, remote sensing and communications, and microtechnology and nanotechnology for national security applications. Engineering's five Centers, in partnership with the Division Leaders and Department Heads, are responsible for guiding the long-term science and technology investments for the Directorate. The Centers represent technologies that have been identified as critical for the present and future work of the Laboratory, and are chartered to develop their respective areas. Their LDRD projects are the key resources to attain this competency, and, as such, nearly all of Engineering's portfolio falls under one of the five Centers. The Centers and their Directors are: (1) Center for Computational Engineering: Robert M. Sharpe; (2) Center for Microtechnology and Nanotechnology: Raymond P. Mariella, Jr.; (3) Center for Nondestructive Characterization: Harry E. Martz, Jr.; (4) Center for Precision Engineering: Keith Carlisle; and (5) Center for Complex Distributed Systems: Gregory J. Suski, Acting Director.« less
The Formation of Indicators on Engineering Laboratory Management
ERIC Educational Resources Information Center
Yasin, Ruhizan M.; Mohamad, Zunuwanas; Rahman, Mohd Nizam Ab.; Hashim, Mohamad Hisyam Mohd
2012-01-01
This research is a developmental study of Engineering Laboratory Management indicators. It is formed to assess the level of quality management of the polytechnic level laboratory. The purpose of indicators is to help provide input into the management process of an engineering laboratory. Effectiveness of teaching and learning at technical…
Contamination source review for Building E3162, Edgewood Area, Aberdeen Proving Ground, Maryland
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, G.A.; Draugelis, A.K.; Rueda, J.
1995-09-01
This report was prepared by Argonne National Laboratory (ANL) to document the results of a contamination source review for Building E3162 at the Aberdeen Proving Ground (APG) in Maryland. The report may be used to assist the US Army in planning for the future use or disposition of this building. The review included a historical records search, physical inspection, photographic documentation, geophysical investigation, and collection of air samples. The field investigations were performed by ANL during 1994 and 1995. Building E3162 (APG designation) is part of the Medical Research Laboratories Building E3160 Complex. This research laboratory complex is located westmore » of Kings Creek, east of the airfield and Ricketts Point Road, and south of Kings Creek Road in the Edgewood Area of APG. The original structures in the E3160 Complex were constructed during World War 2. The complex was originally used as a medical research laboratory. Much of the research involved wound assessment involving chemical warfare agents. Building E3162 was used as a holding and study area for animals involved in non-agent burns. The building was constructed in 1952, placed on inactive status in 1983, and remains unoccupied. Analytical results from these air samples revealed no distinguishable difference in hydrocarbon and chlorinated solvent levels between the two background samples and the sample taken inside Building E3162.« less
McFarlane, A; Aslan, B; Raby, A; Moffat, K A; Selby, R; Padmore, R
2015-12-01
Internal quality control (IQC) procedures are crucial for ensuring accurate patient test results. The IQMH Centre for Proficiency Testing conducted a web-based survey to gather information on the current IQC practices in coagulation testing. A questionnaire was distributed to 174 Ontario laboratories licensed to perform prothrombin time (PT) and activated partial thromboplastin time (APTT). All laboratories reported using two levels of commercial QC (CQC); 12% incorporate pooled patient plasma into their IQC program; >68% run CQC at the beginning of each shift; 56% following maintenance, with reagent changes, during a shift, or with every repeat sample; 6% only run CQC at the beginning of the day and 25% when the instruments have been idle for a defined period of time. IQC run frequency was determined by manufacturer recommendations (71%) but also influenced by the stability of test (27%), clinical impact of an incorrect test result (25%), and sample's batch number (10%). IQC was monitored using preset limits based on standard deviation (66%), precision goals (46%), or allowable performance limits (36%). 95% use multirules. Failure actions include repeating the IQC (90%) and reporting patient results; if repeat passes, 42% perform repeat analysis of all patient samples from last acceptable IQC. Variability exists in coagulation IQC practices among Ontario clinical laboratories. The recommendations presented here would be useful in encouraging standardized IQC practices. © 2015 John Wiley & Sons Ltd.
Fu, Wei; Zhu, Pengyu; Wang, Chenguang; Huang, Kunlun; Du, Zhixin; Tian, Wenying; Wang, Qin; Wang, Huiyu; Xu, Wentao; Zhu, Shuifang
2015-01-01
Digital PCR has developed rapidly since it was first reported in the 1990s. It was recently reported that an improved method facilitated the detection of genetically modified organisms (GMOs). However, to use this improved method, the samples must be pretreated, which could introduce inaccuracy into the results. In our study, we explored a pretreatment-free digital PCR detection method for the screening for GMOs. We chose the CaMV35s promoter and the NOS terminator as the templates in our assay. To determine the specificity of our method, 9 events of GMOs were collected, including MON810, MON863, TC1507, MIR604, MIR162, GA21, T25, NK603 and Bt176. Moreover, the sensitivity, intra-laboratory and inter-laboratory reproducibility of our detection method were assessed. The results showed that the limit of detection of our method was 0.1%, which was lower than the labeling threshold level of the EU. The specificity and stability among the 9 events were consistent, respectively. The intra-laboratory and inter-laboratory reproducibility were both good. Finally, the perfect fitness for the detection of eight double-blind samples indicated the good practicability of our method. In conclusion, the method in our study would allow more sensitive, specific and stable screening detection of the GMO content of international trading products. PMID:26239916
Fu, Wei; Zhu, Pengyu; Wang, Chenguang; Huang, Kunlun; Du, Zhixin; Tian, Wenying; Wang, Qin; Wang, Huiyu; Xu, Wentao; Zhu, Shuifang
2015-08-04
Digital PCR has developed rapidly since it was first reported in the 1990 s. It was recently reported that an improved method facilitated the detection of genetically modified organisms (GMOs). However, to use this improved method, the samples must be pretreated, which could introduce inaccuracy into the results. In our study, we explored a pretreatment-free digital PCR detection method for the screening for GMOs. We chose the CaMV35s promoter and the NOS terminator as the templates in our assay. To determine the specificity of our method, 9 events of GMOs were collected, including MON810, MON863, TC1507, MIR604, MIR162, GA21, T25, NK603 and Bt176. Moreover, the sensitivity, intra-laboratory and inter-laboratory reproducibility of our detection method were assessed. The results showed that the limit of detection of our method was 0.1%, which was lower than the labeling threshold level of the EU. The specificity and stability among the 9 events were consistent, respectively. The intra-laboratory and inter-laboratory reproducibility were both good. Finally, the perfect fitness for the detection of eight double-blind samples indicated the good practicability of our method. In conclusion, the method in our study would allow more sensitive, specific and stable screening detection of the GMO content of international trading products.
Perfectionism and Polysomnography-Determined Markers of Poor Sleep
Johann, Anna F.; Hertenstein, Elisabeth; Kyle, Simon D.; Baglioni, Chiara; Feige, Bernd; Nissen, Christoph; Riemann, Dieter; Spiegelhalder, Kai
2017-01-01
Study Objectives: Perfectionism has been suggested to represent a predisposing factor for poor sleep. However, previous studies have relied on self-reported measures. The association between perfectionism and poor sleep measured by polysomnography (PSG) warrants further investigation. Methods: The current retrospective exploratory study used the Frost Multidimensional Perfectionism Scale and PSG in an unselected sample of 334 consecutive sleep laboratory patients (140 males, 194 females, 44.6 ± 15.9 years). Data were analyzed using linear regression analyses. Results: High levels of perfectionism were associated with PSG-determined markers of poor sleep in the first sleep laboratory night. The total Frost Multidimensional Perfectionism Scale score was significantly associated with the number of nocturnal awakenings in the first sleep laboratory night. The subscales “concern over mistakes” and “personal standards” of perfectionism were significantly associated with markers of poor sleep. In contrast, there were only a few associations between perfectionism and PSG variables of the second sleep laboratory night. Conclusions: This pattern of results suggests that high levels of perfectionism may predispose individuals to sleep disturbances in the context of acute stressors. Thus, the influence of perfectionism on poor sleep should be further investigated to improve treatment. Citation: Johann AF, Hertenstein E, Kyle SD, Baglioni C, Feige B, Nissen C, Riemann D, Spiegelhalder K. Perfectionism and polysomnography-determined markers of poor sleep. J Clin Sleep Med. 2017;13(11):1319–1326. PMID:28992830
Reporting Results of Molecular Tests: A Retrospective Examination of BRAF Mutation Reporting.
Treece, Amanda L; Gulley, Margaret L; Vasalos, Patricia; Paquette, Cherie; Lindeman, Neal I; Jennings, Lawrence J; Bartley, Angela N
2017-05-01
- With enormous growth in the field of molecular pathology, the reporting of results gleaned from this testing is essential to guide patient care. - To examine molecular reports from laboratories participating in proficiency testing for required elements to convey molecular laboratory test results to clinicians and patients. - Molecular laboratories participating in the College of American Pathologists (CAP) proficiency testing program for BRAF mutation analysis were solicited to submit examples of final reports from 2 separate proficiency testing reporting cycles. Reports were reviewed for the presence or absence of relevant components. - A total of 107 evaluable reports were received (57 demonstrating a positive result for the BRAF V600E mutation and 50 negative). Methods for BRAF testing varied, with 95% (102 of 107) of reports adequately describing their assay methods and 87% (93 of 107) of reports adequately describing the target(s) of their assays. Information on the analytic sensitivity of the assay was present in 74% (79 of 107) of reports and 83% (89 of 107) reported at least 1 assay limitation, though only 34% (36 of 107) reported on variants not detected by their assays. Analytic and clinical interpretive comments were included in 99% (106 of 107) and 90% (96 of 107) of reports, respectively. Of participants that perform a laboratory-developed test, 88% (88 of 100) included language addressing the development of the assay. - Laboratories participating in BRAF proficiency testing through the CAP are including most of the required reporting elements to unambiguously convey molecular results. Laboratories should continue to strive to report these results in a concise and comprehensive manner.
Pressman, Mark R
2007-02-01
Sleepwalking and related disorders are the result of factors that predispose, prime and precipitate episodes. In the absence of one or more of these factors sleepwalking is unlikely to occur. Predisposition to sleepwalking is based on genetic susceptibility and has a familial pattern. Priming factors include conditions and substances that increase slow wave sleep (SWS) or make arousal from sleep more difficult. These factors include sleep deprivation, alcohol, medications, situational stress and fever among others. The patient with a genetic predisposition to sleepwalking and with priming factors still requires a precipitating factor or trigger to set the sleepwalking episode in motion. Classical theories of sleepwalking were based primarily on case reports. Recently some of these theories have been tested in the sleep laboratory. Experimental sleep deprivation studies of sleepwalkers generally report an increase in complex behaviors during SWS, although one prominent study reported the opposite effect. However, the generally accepted theory that alcohol and medications can induce sleepwalking episodes remains entirely based on clinical and forensic case reports. Alleged cases of alcohol related sleepwalking often involve individuals lacking the generally accepted characteristics of sleepwalkers but with very high blood alcohol levels that could in and of itself account for complex behaviors noted without the presence of sleepwalking. Further, the effects of high levels of alcohol dramatically decrease SWS, a finding inconsistent with sleepwalking. Case reports of medication-related induction of apparent sleepwalking most often present a complex medical and psychiatric history associated with multiple medications. These patients often lack the clinical history and other criteria currently required for the diagnosis of sleepwalking. The medication-related behaviors may instead represent some other condition in an awake, but impaired patient. Sleep laboratory research has identified sleep disordered breathing, periodic leg movements, noise and touch among others as proximal triggers of sleepwalking episodes. Treatment of these triggers may result in resolution of sleepwalking without medication. Further sleep laboratory research is needed before experimental findings can be used for routine diagnostic and forensic purposes.
NASA Astrophysics Data System (ADS)
Hartman, H.; Engström, L.; Lundberg, H.; Nilsson, H.; Quinet, P.; Fivet, V.; Palmeri, P.; Malcheva, G.; Blagoev, K.
2017-04-01
Aims: This work reports new experimental radiative lifetimes and calculated oscillator strengths for transitions from 3d84d levels of astrophysical interest in singly ionized nickel. Methods: Radiative lifetimes of seven high-lying levels of even parity in Ni II (98 400-100 600 cm-1) have been measured using the time-resolved laser-induced fluorescence method. Two-step photon excitation of ions produced by laser ablation has been utilized to populate the levels. Theoretical calculations of the radiative lifetimes of the measured levels and transition probabilities from these levels are reported. The calculations have been performed using a pseudo-relativistic Hartree-Fock method, taking into account core polarization effects. Results: A new set of transition probabilities and oscillator strengths has been deduced for 477 Ni II transitions of astrophysical interest in the spectral range 194-520 nm depopulating even parity 3d84d levels. The new calculated gf-values are, on the average, about 20% higher than a previous calculation and yield lifetimes within 5% of the experimental values.
Communications: Blood chemistry of laboratory-reared Golden trout
Hunn, Joseph B.; Wiedmeyer, Ray H.; Greer, Ivan E.; Grady, Andrew W.
1992-01-01
Golden trout Oncorhynchus aguabonita obtained from a wild stock as fertilized eggs were reared in the laboratory for 21 months. The laboratory-reared golden trout in our study reached sexual maturity earlier and grew more rapidly than wild golden trout do (according to the scientific literature). Male fish averaged 35.6 cm in total length and 426 g in weight, and females averaged 36.2 cm and 487 g. All golden trout were sexually mature when used for hematological analysis. The hematological profile (hematocrit, red blood cells, white blood cells, and thrombocytes) of golden trout was similar to that reported elsewhere for other trout species. Male and female golden trout did not have significantly different thrombocyte counts; however, the immobilization treatment used on the fish (anesthesia versus a blow to the head) resulted in significant treatment differences in thrombocyte numbers and interaction effect of sex in treatment for hematocrits. Gravid female golden trout had significantly higher plasma protein and calcium levels than did males. The ionic compositions of plasma (sodium, potassium, calcium, magnesium, copper, zinc, iron, and chloride) and gallbladder bile (calcium and chloride) were similar to those reported for other salmonids.
Experimenting with Spirituality: Analyzing The God Gene in a Nonmajors Laboratory Course
2008-01-01
References linking genes to complex human traits, such as personality type or disease susceptibility, abound in the news media and popular culture. In his book The God Gene: How Faith is Hardwired into Our Genes, Dean Hamer argues that a variation in the VMAT2 gene plays a role in one's openness to spiritual experiences. In a nonmajors class, we read and discussed The God Gene and conducted on a small scale an extension of the study it describes. Students used polymerase chain reaction to replicate a portion of their VMAT2 genes, and they analyzed three polymorphic sites in the sequence of these products. Associations between particular VMAT2 alleles and scores on a personality test were assessed by t test. The course, of which this project was a major part, stimulated student learning; scores on a test covering basic genetic concepts, causation/correlation, and laboratory methodology improved after completion of the course. In a survey, students reported the laboratory project aided their learning, especially in the areas of statistics and the linking of genes to behaviors. They reported high levels of engagement with the project, citing in particular its personal nature as motivating their interest. PMID:18316816
Kiley, Kasey B.; Haywood, Carlton; Bediako, Shawn M.; Lanzkron, Sophie; Carroll, C. Patrick; Buenaver, Luis F.; Pejsa, Megan; Edwards, Robert R.; Haythornthwaite, Jennifer A.; Campbell, Claudia M.
2016-01-01
Objective: People living with sickle cell disease (SCD) experience severe episodic and chronic pain and frequently report poor interpersonal treatment within health-care settings. In this particularly relevant context, we examined the relationship between perceived discrimination and both clinical and laboratory pain. Methods: Seventy-one individuals with SCD provided self-reports of experiences with discrimination in health-care settings and clinical pain severity, and completed a psychophysical pain testing battery in the laboratory. Results: Discrimination in health-care settings was correlated with greater clinical pain severity and enhanced sensitivity to multiple laboratory-induced pain measures, as well as stress, depression, and sleep. After controlling for relevant covariates, discrimination remained a significant predictor of mechanical temporal summation (a marker of central pain facilitation), but not clinical pain severity or suprathreshold heat pain response. Furthermore, a significant interaction between experience with discrimination and clinical pain severity was associated with mechanical temporal summation; increased experience with discrimination was associated with an increased correlation between clinical pain severity and temporal summation of pain. Discussion: Perceived discrimination within health-care settings was associated with pain facilitation. These findings suggest that discrimination may be related to increased central sensitization among SCD patients, and more broadly that health-care social environments may interact with pain pathophysiology. PMID:26889615
Creative Report Writing in Undergraduate Organic Chemistry Laboratory Inspires Nonmajors
ERIC Educational Resources Information Center
Henary, Maged; Owens, Eric A.; Tawney, Joseph G.
2015-01-01
Laboratory-based courses require students to compose reports based on the performed experiments to assess their overall understanding of the presented material; unfortunately, the sterile and formulated nature of the laboratory report disinterests most students. As a result, the outcome is a lower-quality product that does not reveal full…
Laboratory Indices of Nutritional Status in Pregnancy. Summary Report.
ERIC Educational Resources Information Center
National Academy of Sciences-National Research Council, Washington, DC. Food and Nutrition Board.
This report, a condensation of a publication titled "Laboratory Indices of Nutritional Status in Pregnancy," summarizes the effects of normal gestation on certain laboratory indices of nutritional and metabolic status in an effort to provide the clinician with normative data applicable to healthy pregnant women. The report is divided into six…
Directed Self-Inquiry: A Scaffold for Teaching Laboratory Report Writing
ERIC Educational Resources Information Center
Deiner, L. Jay; Newsome, Daniel; Samaroo, Diana
2012-01-01
A scaffold was created for the explicit instruction of laboratory report writing. The scaffold breaks the laboratory report into sections and teaches students to ask and answer questions in order to generate section-appropriate content and language. Implementation of the scaffold is done through a series of section-specific worksheets that are…
Laboratory Directed Research and Development FY-15 Annual Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pillai, Rekha Sukamar
The Laboratory Directed Research and Development (LDRD) Program at Idaho National Laboratory (INL) reports its status to the U.S. Department of Energy (DOE) by March of each year. The program operates under the authority of DOE Order 413.2B, “Laboratory Directed Research and Development” (April 19, 2006), which establishes DOE’s requirements for the program while providing the laboratory director broad flexibility for program implementation. LDRD funds are obtained through a charge to all INL programs. This report includes summaries of all INL LDRD research activities supported during Fiscal Year (FY) 2015.
Husmann, Polly R; O'Loughlin, Valerie Dean; Braun, Mark W
2009-10-01
This study compares overall laboratory averages and individual test scores along with a student survey to determine the effects of using virtual microscopy in place of optical microscopes in a large undergraduate human anatomy course. T-tests revealed that the first two laboratory examinations (of four) and the overall laboratory averages were significantly increased compared with the previous year. We hypothesize that this is due to students' ability to use and understand the technology quickly as opposed to learning how to maneuver an optical microscope. Students also responded positively in a survey about the virtual microscope, indicating that increased accessibility, ease of use, and the ability to understand the material were important components of the virtual microscope. In addition, an increase in student collaboration was noted because multiple students were able to view the image at a time. This level of acceptance of virtual microscopy has been reported in previous studies, though this level of increased examination scores is rare. We attribute this to differences between the medical students, with whom this technology has been researched in the past, and undergraduate introductory students.
Iron Phosphate Glass-Containing Hanford Waste Simulant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sevigny, Gary J.; Kimura, Marcia L.; Fischer, Christopher M.
2012-01-18
Resolution of the nation's high-level tank waste legacy requires the design, construction, and operation of large and technically complex one-of-a-kind processing waste treatment and vitrification facilities. While the ultimate limits for waste loading and melter efficiency have yet to be defined or realized, significant reductions in glass volumes for disposal and mission life may be possible with advancements in melter technologies and/or glass formulations. This test report describes the experimental results from a small-scale test using the research-scale melter (RSM) at Pacific Northwest National Laboratory (PNNL) to demonstrate the viability of iron-phosphate-based glass with a selected waste composition that ismore » high in sulfate (4.37 wt% SO3). The primary objective of the test was to develop data to support a cost-benefit analysis related to the implementation of phosphate-based glasses for Hanford low-activity waste (LAW) and/or other high-level waste streams within the U.S. Department of Energy complex. The testing was performed by PNNL and supported by Idaho National Laboratory, Savannah River National Laboratory, Missouri University of Science and Technology, and Mo-Sci Corporation.« less
Hood-Degrenier, Jennifer K
2008-01-01
The movement of newly synthesized proteins through the endomembrane system of eukaryotic cells, often referred to generally as the secretory pathway, is a topic covered in most intermediate-level undergraduate cell biology courses. An article previously published in this journal described a laboratory exercise in which yeast mutants defective in two distinct steps of protein secretion were differentiated using a genetic reporter designed specifically to identify defects in the first step of the pathway, the insertion of proteins into the endoplasmic reticulum (Vallen, 2002). We have developed two versions of a Western blotting assay that serves as a second way of distinguishing the two secretory mutants, which we pair with the genetic assay in a 3-wk laboratory module. A quiz administered before and after students participated in the lab activities revealed significant postlab gains in their understanding of the secretory pathway and experimental techniques used to study it. A second survey administered at the end of the lab module assessed student perceptions of the efficacy of the lab activities; the results of this survey indicated that the experiments were successful in meeting a set of educational goals defined by the instructor.
Surveys of research in the Chemistry Division, Argonne National Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grazis, B.M.
1992-01-01
Research reports are presented on reactive intermediates in condensed phase (radiation chemistry, photochemistry), electron transfer and energy conversion, photosynthesis and solar energy conversion, metal cluster chemistry, chemical dynamics in gas phase, photoionization-photoelectrons, characterization and reactivity of coal and coal macerals, premium coal sample program, chemical separations, heavy elements coordination chemistry, heavy elements photophysics/photochemistry, f-electron interactions, radiation chemistry of high-level wastes (gas generation in waste tanks), ultrafast molecular electronic devices, and nuclear medicine. Separate abstracts have been prepared. Accelerator activites and computer system/network services are also reported.
Surveys of research in the Chemistry Division, Argonne National Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grazis, B.M.
1992-11-01
Research reports are presented on reactive intermediates in condensed phase (radiation chemistry, photochemistry), electron transfer and energy conversion, photosynthesis and solar energy conversion, metal cluster chemistry, chemical dynamics in gas phase, photoionization-photoelectrons, characterization and reactivity of coal and coal macerals, premium coal sample program, chemical separations, heavy elements coordination chemistry, heavy elements photophysics/photochemistry, f-electron interactions, radiation chemistry of high-level wastes (gas generation in waste tanks), ultrafast molecular electronic devices, and nuclear medicine. Separate abstracts have been prepared. Accelerator activites and computer system/network services are also reported.
Publications of the U.S. Army Engineer Research and Development Center: October 1999-December 2015
2017-01-01
Ebeling, R.W. Strom, J.E. Hite Jr., R.W. Haskins, and J.A. Evans ADA582963 ERDC TR-13-4 Aug 2013 Small Wind Turbine Installation Compatibility...M.W. Tubman ADA469604 ERDC/CHL TR-07-4 Jul 2007 Laboratory Study of Wind Effect on Runup over Fringing Reefs. Report 1, Data Report, by Z...Extratropical Storm Wind , Wave, and Water Level Climatology for the Offshore Mid-Atlantic, by M.F. Forte and J.L. Hanson ADA621324 ERDC/CHL TR
A Study of the Magnetic and Metallurgical Properties of Sm(Co,Fe,Cu,Zr) z Alloys with z = 8.5.
1981-01-28
CY NAME A DORESS0it dIIG.’t from, Cont~rolling Of4’lc%) !5. SECURITY CLASS. fof this report) 3 Unclassi fled LEVEL SCHEDULE 16. DISTRIBUTION STATE14ENT... SECURITY CLASSIFICATION OF THIS PAGE(~Whe Does Entered) 16993. 1 -MS F20. AB3TBACT CO,)TINUEl Jcommerical laboratories in Japan reported that by adding...properties, before the sub- microscopic structure studies that seem to be needed for a true understanding make any sense . Similarly, it was necessary tc
DOE Office of Scientific and Technical Information (OSTI.GOV)
Delbar, T.; Gregoire, G.; Lega, J.
1976-10-01
The spectra from the reaction /sup 9/Be(p, ..cap alpha..)/sup 6/Li induced by 75 and 30 MeV protons were recorded at theta/sub ..cap alpha../ = 20 and 30/sup 0/ in the laboratory frame. The region from 6 to 18 MeV excitation energy of the residual nucleus was carefully studied for possible levels. Evidence for a T = 1 level at E/sub x/ = 8.2 +- 0.2 MeV with a width GAMMA = 2.2 +- 0.2 MeV is reported. No other levels were observed in the present spectra. (AIP)
Oral, Bulent; Cullen, Regina M; Diaz, Danny L; Hod, Eldad A; Kratz, Alexander
2015-01-01
Downtimes of the laboratory information system (LIS) or its interface to the electronic medical record (EMR) disrupt the reporting of laboratory results. Traditionally, laboratories have relied on paper-based or phone-based reporting methods during these events. We developed a novel downtime procedure that combines advance placement of orders by clinicians for planned downtimes, the printing of laboratory results from instruments, and scanning of the instrument printouts into our EMR. The new procedure allows the analysis of samples from planned phlebotomies with no delays, even during LIS downtimes. It also enables the electronic reporting of all clinically urgent results during downtimes, including intensive care and emergency department samples, thereby largely avoiding paper- and phone-based communication of laboratory results. With the capabilities of EMRs and LISs rapidly evolving, information technology (IT) teams, laboratories, and clinicians need to collaborate closely, review their systems' capabilities, and design innovative ways to apply all available IT functions to optimize patient care during downtimes. Copyright© by the American Society for Clinical Pathology.
[Effect of beta-ecdysterone in competitive cultures of Drosophila melanogaster].
Botella, L M; Ménsua, J L
1987-03-01
High levels of beta-ecdysterone (more than 1 microgram/ml) have been shown to decrease larva-adult viability and to speed up developmental times when supplied to the media in crowding cultures. The highest doses (100 micrograms/ml) of ecdysterone suppresses almost completely the phenomenon of larval stop in the third instar of development, first reported by our laboratory in overcrowded situations. Thus, one may deduce that stopped larvae could have low levels of ecdysone, and perhaps these are the ultimate physiological cause of their arrested development before the critical larva-pupa molt.
Grimmett, Paul E; Munch, Jean W
2009-01-01
1,4-Dioxane has been identified as a probable human carcinogen and an emerging contaminant in drinking water. The United States Environmental Protection Agency's (U.S. EPA) National Exposure Research Laboratory (NERL) has developed a method for the analysis of 1,4-dioxane in drinking water at ng/L concentrations. The method consists of an activated carbon solid-phase extraction of 500-mL or 100-mL water samples using dichloromethane as the elution solvent. The extracts are analyzed by gas chromatography-mass spectrometry (GC-MS) in selected ion monitoring (SIM) mode. In the NERL laboratory, recovery of 1,4-dioxane ranged from 94-110% in fortified laboratory reagent water and recoveries of 96-102% were demonstrated for fortified drinking water samples. The relative standard deviations for replicate analyses were less than 6% at concentrations exceeding the minimum reporting level.
Kiel, Elizabeth J; Buss, Kristin A
2010-07-03
OBJECTIVE: Although maternal internalizing symptoms and parenting dimensions have been linked to reports and perceptions of children's behavior, it remains relatively unknown whether these characteristics relate to expectations or the accuracy of expectations for toddlers' responses to novel situations. DESIGN: A community sample of 117 mother-toddler dyads participated in a laboratory visit and questionnaire completion. At the laboratory, mothers were interviewed about their expectations for their toddlers' behaviors in a variety of novel tasks; toddlers then participated in these activities, and trained coders scored their behaviors. Mothers completed questionnaires assessing demographics, depressive and worry symptoms, and parenting dimensions. RESULTS: Mothers who reported more worry expected their toddlers to display more fearful behavior during the laboratory tasks, but worry did not moderate how accurately maternal expectations predicted toddlers' observed behavior. When also reporting a low level of authoritative-responsive parenting, maternal depressive symptoms moderated the association between maternal expectations and observed toddler behavior, such that, as depressive symptoms increased, maternal expectations related less strongly to toddler behavior. CONCLUSIONS: When mothers were asked about their expectations for their toddlers' behavior in the same novel situations from which experimenters observe this behavior, symptoms and parenting had minimal effect on the accuracy of mothers' expectations. When in the context of low authoritative-responsive parenting, however, depressive symptoms related to less accurate predictions of their toddlers' fearful behavior.
The levels of edit, second edition
NASA Technical Reports Server (NTRS)
Vanburen, R.; Buehler, M. F.
1980-01-01
The editorial process is analyzed, and five levels of edit are identified. These levels represent cumulative combinations of nine types of edit: Coordination, Policy, Integrity, Screening, Copy Clarification, Format, Mechanical Style, Language, and Substantive. The levels and types of edit, although developed for specific use with external reports at the Jet Propulsion Laboratory, cover the general range of technical editing, especially as it applies to an in-house technical publications organization. Each type of edit is set forth in terms of groups of actions to be performed by editor. The edit-level concept has enhanced understanding and communication among editors, authors, and publications managers concerning the specific editorial work to be done on each manuscript. It has also proved useful as a management tool for estimating and monitoring cost.
International External Quality Assurance for Laboratory Diagnosis of Diphtheria ▿
Neal, S. E.; Efstratiou, A.
2009-01-01
The diphtheria surveillance network (DIPNET) encompassing National Diphtheria Reference Centers from 25 European countries is a Dedicated Surveillance Network recognized by the European Commission. A key DIPNET objective is the quality assessment of microbiological procedures for diphtheria across the European Union and beyond. A detailed questionnaire on the level of reference laboratory services and an external quality assessment (EQA) panel comprising six simulated throat specimens were sent to 34 centers. Twenty-three centers are designated National Diphtheria Reference Centers, with the laboratory in the United Kingdom being the only WHO Collaborating Centre. A variety of screening and identification tests were used, including the cysteinase test (20/34 centers), pyrazinamidase test (17/34 centers), and commercial kits (25/34 centers). The classic Elek test for toxigenicity testing is mostly used (28/34 centers), with variations in serum sources and antitoxin concentrations. Many laboratories reported problems obtaining Elek reagents or media. Only six centers produced acceptable results for all six specimens. Overall, 21% of identification and 13% of toxigenicity reports were unacceptable. Many centers could not isolate the target organism, and most found difficulties with the specimens that contained Corynebacterium striatum as a commensal contaminant. Nineteen centers generated either false-positive or negative toxigenic results, which may have caused inappropriate medical management. The discrepancies in this diphtheria diagnostics EQA alarmingly reflect the urgent need to improve laboratory performance in diphtheria diagnostics in Europe, standardize feasible and robust microbiological methods, and build awareness among public health authorities. Therefore, DIPNET recommends that regular workshops and EQA distributions for diphtheria diagnostics should be supported and maintained. PMID:19828749
Teaching advanced science concepts through Freshman Research Immersion
NASA Astrophysics Data System (ADS)
Wahila, M. J.; Amey-Proper, J.; Jones, W. E.; Stamp, N.; Piper, L. F. J.
2017-03-01
We have developed a new introductory physics/chemistry programme that teaches advanced science topics and practical laboratory skills to freshmen undergraduate students through the use of student-led, bona fide research activities. While many recent attempts to improve college-level physics education have focused on integrating interactive demonstrations and activities into traditional passive lectures, we have taken the idea of active-learning several steps further. Working in conjunction with several research faculty at Binghamton University, we have created a programme that puts undergraduate students on an accelerated path towards working in real research laboratories performing publishable research. Herein, we describe in detail the programme goals, structure, and educational content, and report on our promising initial student outcomes.
Antiepileptic drug therapy: clinical laboratory significance.
Naradzay, J F; Olshaker, J S
1996-01-01
When evaluating a patient who is taking an antiepileptic medication, it is important for the emergency physician to correlate the clinical presentation with the antiepileptic drug level. Therapeutic ranges have been suggested for most antiepileptic medications, but these must be interpreted in light of clinical efficacy and patient tolerance. When considering the efficacy of anti-epileptic medications, it is necessary to consider the patient's unique metabolism, side-effect tolerance, and overall response to therapy. Suggested therapeutic ranges should be the first reference for the emergency physician. The purpose of this report is to discuss the laboratory values of commonly prescribed antiepileptic medications. Therapeutic ranges, side-effects, and common medication interactions are discussed concerning phenytoin, phenobarbital, carbamezapine, and valproic acid.
Sezen, Figen; Albayrak, Nurhan; Özkara, Şeref; Karagöz, Alper; Alp, Alpaslan; Duyar Ağca, Filiz; İnan Süer, Asiye; Müderris, Tuba; Ceyhan, İsmail; Durmaz, Rıza; Ertek, Mustafa
2015-04-01
The most effective method for monitoring country-level drug resistance frequency and to implement the necessary control measures is the establishment of a laboratory-based surveillance system. The aim of this study was to summarize the follow up trend of the drug-resistant tuberculosis (TB) cases, determine the load of resistance and evaluate the capacities of laboratories depending on laboratory quality assurance system for the installation work of National Tuberculosis Laboratory Surveillance Network (TuLSA) which has started in Ankara in 2011. TuLSA studies was carried out under the coordination of National Tuberculosis Reference Laboratory (NRL) with the participation of TB laboratories and dispensaries. Specimens of TB patients, reported from health institutions, were followed in TB laboratories, and the epidemiological information was collected from the dispensaries. One isolate per patient with the drug susceptibility test (DST) results were sent to NRL from TB laboratories and in NRL the isolates were rechecked with the genotypical (MTBDRplus, Hain Lifescience, Germany) and phenotypical (MGIT 960, BD, USA) DST methods. Molecular epidemiological analysis were also performed by spoligotyping and MIRU/VNTR. Second-line DST was applied to the isolates resistant to rifampin. A total of 1276 patients were reported between January 1st to December 31th 2011, and 335 cases were defined as "pulmonary TB from Ankara province". The mean age of those patients was 43.4 ± 20 years, and 67.5% were male. Three hundred seventeen (94.6%) patients were identified as new cases. The average sample number obtained from pulmonary TB cases was 3.26 ± 2.88, and 229 (68.3%) of them was culture positive. DST was applied to all culture positive isolates; 90.4% (207/229) of cases were susceptible to the five drugs tested (ethambutol, isoniazid, pyrazinamide, rifampicin, streptomycin). Eight (3.5%) of the isolates were multidrug-resistant (MDR-TB), while no extensively drug-resistant strains were detected. MDR-TB is likely to occur in 63.3 times more among previously treated cases, and 73.3 times more in legal aliens. The achievement of therapy among pulmonary TB cases was 91.9%. Spoligotyping performed for 221 M.tuberculosis complex isolates, showed that all strains were clustered in nine groups. SIT 41 (105/221; 47.5%) was the most frequent spoligotype detected, and clustering rate based on MIRU-VNTR results were found as 16.3%. All of the clustered strains were sensitive while all of MDR-TB isolates showed specific MIRU-VNTR profiles. In conclusion, TuLSA studies started in Ankara in 2011 and the system is still expanding in the country. Our data obtained with TuLSA have been published as a regional surveillance data in the WHO Global Tuberculosis Report 2011, and as a national surveillance data in Global Tuberculosis Report 2012.
Honeycutt, Jennifer A; Nguyen, Jenny Q T; Kentner, Amanda C; Brenhouse, Heather C
2017-05-01
Bisphenol A (BPA) is widely used in the polycarbonate plastics and epoxy resins that are found in laboratory animal husbandry materials including cages and water bottles. Concerns about BPA exposure in humans has led to investigations that suggest physiologic health risks including disruptions to the endocrine system and CNS. However, the extent of exposure of laboratory animals to BPA in drinking water is unclear. In the first study, we compared the amount of BPA contamination in water stored in plastic bottles used in research settings with that in glass bottles. The amount of BPA that leached into water was measured across several time points ranging from 24 to 96 h by using a BPA ELISA assay. The results showed that considerable amounts of BPA (approximately 0.15 μg/L) leached from polycarbonate bottles within the first 24 h of storage. In the second study, BPA levels were measured directly from water taken from filtered compared with unfiltered taps. We observed significantly higher BPA levels in water from unfiltered taps (approximately 0.40 μg/L) compared with taps with filtration systems (approximately 0.04 μg/L). Taken together, our findings indicate that the use of different types of water bottles and water sources, combined with the use of different laboratory products (food, caging systems) between laboratories, likely contribute to decreased rigor and reproducibility in research. We suggest that researchers consider reporting the types of water bottles used and that animal care facilities educate staff regarding the importance of flushing nonfiltered water taps when filling animal water bottles.
Honeycutt, Jennifer A; Nguyen, Jenny Q T; Kentner, Amanda C; Brenhouse, Heather C
2017-01-01
Bisphenol A (BPA) is widely used in the polycarbonate plastics and epoxy resins that are found in laboratory animal husbandry materials including cages and water bottles. Concerns about BPA exposure in humans has led to investigations that suggest physiologic health risks including disruptions to the endocrine system and CNS. However, the extent of exposure of laboratory animals to BPA in drinking water is unclear. In the first study, we compared the amount of BPA contamination in water stored in plastic bottles used in research settings with that in glass bottles. The amount of BPA that leached into water was measured across several time points ranging from 24 to 96 h by using a BPA ELISA assay. The results showed that considerable amounts of BPA (approximately 0.15 μg/L) leached from polycarbonate bottles within the first 24 h of storage. In the second study, BPA levels were measured directly from water taken from filtered compared with unfiltered taps. We observed significantly higher BPA levels in water from unfiltered taps (approximately 0.40 μg/L) compared with taps with filtration systems (approximately 0.04 μg/L). Taken together, our findings indicate that the use of different types of water bottles and water sources, combined with the use of different laboratory products (food, caging systems) between laboratories, likely contribute to decreased rigor and reproducibility in research. We suggest that researchers consider reporting the types of water bottles used and that animal care facilities educate staff regarding the importance of flushing nonfiltered water taps when filling animal water bottles. PMID:28535862
Volmar, Keith E; Wilkinson, David S; Wagar, Elizabeth A; Lehman, Christopher M
2013-02-01
Utilization of stat testing priority is a balance between safe, efficient patient management and resource expenditure. To determine the rate of stat testing, compare rates among institutions, and determine the distribution of turnaround time expectations for different turnaround time priorities. During a 7-day period, participants prospectively determined the total number of chemistry, hematology, and coagulation billable tests from inpatients and emergency department patients. Among these, the total numbers of billable tests performed stat were identified. Laboratories also reported the levels of test priority they offered and turnaround expectations for each level of test priority. Fifty institutions submitted data for the study, with 2 additional participants submitting partial results. Participants identified 639 589 chemistry, hematology, and coagulation billable tests, with 229 896 (35.9%) performed stat. The stat rate varied from 21.3% at the 10th percentile to 55.4% at the 90th percentile, with a median of 37.0% of participants' tests performed stat. Laboratories include a mean of 206 tests in chemistry, hematology, and coagulation test menus, with 67% of these tests offered stat. The fraction of the test menu offered stat varied from 29.0% at the 10th percentile to 97.8% at the 90th percentile, with a median of 73.3% of tests on the menu offered stat. The most common number of testing priorities offered by participating laboratories was 3 (44.2%). Among the 52 participating laboratories, the median stat testing rate was 37.0% and a median 73.3% of the test menu was offered stat.
Kubo, Shoji; Takemura, Shigekazu; Sakata, Chikaharu; Urata, Yorihisa; Nishioka, Takayoshi; Nozawa, Akinori; Kinoshita, Masahiko; Hamano, Genya; Nakanuma, Yasuni; Endo, Ginji
2014-01-01
A cholangiocarcinoma outbreak among workers of an offset color proof-printing department in a printing company was recently reported. It is important to understand the clinical course leading to occupational cholangiocarcinoma development for investigation of the carcinogenesis process and for surveillance and early detection. We evaluated the changes in laboratory test results and diagnostic imaging presentation before the detection of cholangiocarcinoma. We investigated the changes in laboratory test results and diagnostic imaging presentation before the detection of cholangiocarcinoma in 2 patients because the data were available. Results The clinical courses observed in the 2 participating patients showed persistent elevation of serum γ-glutamyl transpeptidase levels with or without elevated serum levels of alanine aminotransferase and/or aspartate aminotransferase before cholangiocarcinoma detection. Dilatation of the bile ducts without tumor-induced stenosis was observed several years before cholangiocarcinoma detection and progressed gradually in both patients. The serum concentration of carbohydrate 19-9 also increased prior to cholangiocarcinoma detection in both patients. Eventually, observation of stenosis of the bile duct and a space-occupying lesion strongly suggested cholangiocarcinoma. Pathological examination of the resected specimens showed chronic bile duct injury and neoplastic lesions, such as "biliary intraepithelial neoplasia" and "intraductal papillary neoplasm of the bile duct" in various sites of the bile ducts, particularly in the dilated bile ducts. The changes in laboratory test results and diagnostic imaging might be related to the development of cholangiocarcinoma. It is important to monitor diagnostic imaging presentation and laboratory test results in workers with extended exposure to organic solvents.
Laboratory Measurement Implications of Decreasing Childhood Blood Lead Levels
Caldwell, Kathleen L.; Cheng, Po-Yung; Jarrett, Jeffery M.; Makhmudov, Amir; Vance, Kathryn; Ward, Cynthia D.; Jones, Robert L.; Mortensen, Mary E.
2017-01-01
In 2012, the Centers for Disease Control and Prevention (CDC) adopted its Advisory Committee on Childhood Lead Poisoning Prevention (ACCLPP) recommendation to use a population-based reference value to identify children and environments associated with lead hazards. The current reference value of 5 μg/dL is calculated as the 97.5th percentile of the distribution of blood lead levels (BLL) in children one to five years old from 2007–2010 National Health and Nutrition Examination Survey (NHANES) data. We calculated and updated selected percentiles, including the 97.5th percentile, using NHANES 2011–2014 blood lead data and examined demographic characteristics of children whose blood lead was ≥90th percentile value. The 97.5% percentile BLL of 3.48 μg/dL highlighted analytical laboratory and clinical interpretation challenges of blood lead measurements ≤ 5 μg/dL. Review of five years of results for target blood lead values < 11 μg/dL for U.S. clinical laboratories participating in CDC’s voluntary Lead and Multi-Element Proficiency (LAMP) quality assurance program showed 40% unable to quantify and reported a non-detectable result at a target blood lead value of 1.48 μg/dL compared 5.5 % at a target blood lead of 4.60 μg/dL. We describe actions taken at CDC’s Environmental Health Laboratory in the Division of Laboratory Sciences, which measures blood lead for NHANES, to improve analytical accuracy and precision and to reduce external lead contamination during blood collection and analysis. PMID:28771411
The communication of laboratory investigations by university entrants
NASA Astrophysics Data System (ADS)
Campbell, Bob; Kaunda, Loveness; Allie, Saalih; Buffler, Andy; Lubben, Fred
2000-10-01
The purpose of the study reported here was to analyse the ways in which unversity entrant science students carry out and communicate experimental activities and to identify a model to explain characteristic communication practices. The study was prompted by a need to inform the development of an introductory laboratory course. The students studied shared an educational background characterised by a lack of experience with laboratory work and scientific writing. Seven groups of three students were studied. The investigative strategies of these groups were observed. Laboratory reports were used to identify the ways in which students communicated these strategies. Data are presented that show a discrepancy between the strategies used and those reported. The results suggest that: (i) students' perceptions of the purpose of a laboratory task influence their decisions on what to report; (ii) understandings of laboratory procedures greatly influence their decision on what to report and on how much detail to include in a report and; (iii) knowledge of discourse rules contributes to effective reporting. It is concluded that students' communication of an investigation results from the differential operation of various perceptual filters that determine both the procedural and discourse elements of their reports. It is recommended that the communication of science should be taught explicitly and alongside the procedures and concepts of science.
Chudnoff, Scott G; Liu, Connie S; Levie, Mark D; Bernstein, Peter; Banks, Erika H
2010-09-01
To assess whether a novel educational curriculum using a simulation teaching laboratory improves resident knowledge, comfort with, and surgical performance of hysteroscopic sterilization. An educational prospective, pretest/posttest study. The Montefiore Institute of Minimally Invasive Surgery Laboratory. PATIENT(S)/SUBJECT(S): Thirty-four OB/GYN residents in an academic medical center. Hysteroscopic sterilization simulation laboratory and a brief didactic lecture. Differences in scores on validated skill assessment tools: Task specific checklist, Global Rating Scale (GRS), pass fail assessment, and a multiple-choice examination to evaluate knowledge and attitude. In the entire cohort improvements were observed on all evaluation tools after the simulation laboratory, with 31% points (SD+/-11.5, 95% confidence interval [CI] 27.3-35.3) higher score on the written evaluation; 63% points (SD+/-15.7, 95% CI 57.8-68.8) higher score on the task specific checklist; and 54% points (SD+/-13.6, 95% CI 48.8-58.3) higher score on the GRS. Higher PGY status was correlated with better pretest performance, but was not statistically significant in posttest scores. Residents reported an improvement in comfort performing the procedure after the laboratory. Simulation laboratory teaching significantly improved resident knowledge, comfort level, and technical skill performance of hysteroscopic sterilization. Copyright (c) 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Nightshade Prototype Experiments (Silverleaf)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Danielson, Jeremy; Bauer, Amy L.
2016-12-23
The Red Sage campaign is a series of subcritical dynamic plutonium experiments designed to measure ejecta. Nightshade, the first experiments in Red Sage scheduled for fiscal year 2019, will measure the amount of ejecta emission into vacuum from a double-shocked plutonium surface. To address the major technical risks in Nightshade, a Level 2 milestone was developed for fiscal year 2016. Silverleaf, a series of four experiments, was executed at the Los Alamos National Laboratory in July and August 2016 to demonstrate a prototype of the Nightshade package and to satisfy this Level 2 milestone. This report is documentation that Redmore » Sage Level 2 milestone requirements were successfully met.« less
1991-09-27
AD-A241 692 II I] II I11 ANNUAL REPORT VOLUME 1 PART 2 TASK 1: DIGITAL EMULATION TECHNOLOGY LABORATOIRY REPORT NO. AR-0142-91-001 September 27, 1991... DIGITAL EMULATION TECHNOLOGY LABORATORY Contract No. DASG60-89-C-0142 Sponsored By The United States Army ? trategic Defense Command COMPUTER...ANNUAL REPORT VOLUME 1 PART 2 TASK 1: DIGITAL EMULATION TECHNOLOGY LABORATORY September 27, 1991 Authors Thomas R. Collins and Stephen R. Wachtel
ERIC Educational Resources Information Center
Jablonski, Ann M.
The purpose of this paper is twofold: to describe the revision of an experimental preservice teacher education program at Fordham University (New York) and to report the level of interns' perceived self-efficacy at the end of the summer instructional training laboratory. The method for revising the design of the Internship Fellowship Program using…
ERIC Educational Resources Information Center
Ryan, William C., Ed.
The l50 papers and 28 panel discussion reports in this collection focus on innovations, trends, and research in the use of computers in a variety of educational settings. Topics discussed include: computer centers and laboratories; use of computer at various levels from K-12 through the university, including inservice teacher training; use of…
Air Force Human Resources Laboratory Annual Report - Fiscal Year 1982.
1983-06-01
test are used a clearer understanding of the impact of sample to assess literacy skills . The use of AFRAT size and curtailment on calibration accuracy...training within determine the feasibility of using newly devised Specialized Undergraduate Pilot Training. tests of psychomotor skills , information...individual skill underscored by unacceptable levels of literacy deficiencies. Empirical job requirements and among recent military enlistees. Plans are
ERIC Educational Resources Information Center
Marcovitz, Alan B., Ed.
Four computer programs written in FORTRAN and BASIC develop theoretical predictions and data reduction for a junior-senior level heat exchanger experiment. Programs may be used at the terminal in the laboratory to check progress of the experiment or may be used in the batch mode for interpretation of final information for a formal report. Several…
Bulk shielding facility quarterly report, October, November, and December 1976
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hurt, III, S. S.; Lance, E. D.; Thomas, J. R.
1977-08-01
The BSR operated at an average power level of 1,836 kw for 78.01 percent of the time during October, November, and December. Water-quality control in both the reactor primary and secondary cooling systems was satisfactory. The PCA was used in training programs and was operated on two occasions when the University of Kentucky students actively participated in training laboratories.
Circadian Biology and Sleep: Missing Links in Obesity and Metabolism
2009-05-01
Department of Defense, Washington Headquarters Services , Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite...Army and academic laboratories, both national and international . Much of the information related at the symposium will be made available to the...deprivation to increase appetite by decreasing leptin and increasing ghrelin levels. Inadequate sleep and poor- quality sleep are associated with obesity in
ERIC Educational Resources Information Center
Dougherty, Knowles
The Comprehensive School Mathematics Program (CSMP) is a program of CEMREL, Inc., one of the national educational laboratories, and was funded by the National Institute of Education (NIE). Its major purpose is the development of curriculum materials for kindergarten through grade 6. This document is an extension of "Evaluation Report…
ERIC Educational Resources Information Center
Dougherty, Knowles
The Comprehensive School Mathematics Program (CSMP) is a program of CEMREL, Inc., one of the national educational laboratories, and was funded by the National Institute of Education (NIE). Its major purpose is the development of curriculum materials for kindergarten through grade 6. This study compared CSMP and non-CSMP students' performance at…
Self-reported pain intensity with the numeric reporting scale in adult dengue.
Wong, Joshua G X; Gan, Victor C; Ng, Ee-Ling; Leo, Yee-Sin; Chan, Siew-Pang; Choo, Robin; Lye, David C
2014-01-01
Pain is a prominent feature of acute dengue as well as a clinical criterion in World Health Organization guidelines in diagnosing dengue. We conducted a prospective cohort study to compare levels of pain during acute dengue between different ethnicities and dengue severity. Demographic, clinical and laboratory data were collected. Data on self-reported pain was collected using the 11-point Numerical Rating Scale. Generalized structural equation models were built to predict progression to severe disease. A total of 499 laboratory confirmed dengue patients were recruited in the Prospective Adult Dengue Study at Tan Tock Seng Hospital, Singapore. We found no statistically significant differences between pain score with age, gender, ethnicity or the presence of co-morbidity. Pain score was not predictive of dengue severity but highly correlated to patients' day of illness. Prevalence of abdominal pain in our cohort was 19%. There was no difference in abdominal pain score between grades of dengue severity. Dengue is a painful disease. Patients suffer more pain at the earlier phase of illness. However, pain score cannot be used to predict a patient's progression to severe disease.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phillips, G.W.; August, R.A.; King, S.E.
1996-01-14
This progress report covers field work and laboratory analysis efforts for quantifying the environmental threat of radioactive waste released in the Arctic seas adjacent to the former Soviet Union and for studying the various transport mechanisms by which this radioactivity could effect populations of the U.S. and other countries bordering the Arctic. We obtained water, sediment, biological samples and oceanographic data from several cruises to the Kara Sea and adjacent waters and conducted detailed laboratory analyses of the samples for radionuclides and physical biological properties. In addition, we obtained water and sediment samples and conducted on site low level radionuclidemore » analysis on the Angara, Yenisey River system which drains a major part of the Siberian industrial heartland and empties into the Kara Sea. We report on radionuclide concentrations, on radionuclide transport and scrubbing by sediments, on adsorption by suspended particles, on transport by surface and benthic boundary layer currents, on the effects of benthic and demersal organisms, on studies of long term monitoring in the Arctic, and on an interlaboratory calibration for radionuclide analysis.« less
Space Science Laboratory publications and presentations, 1 January - 31 December 1991
NASA Technical Reports Server (NTRS)
Moorehead, Tauna W.
1992-01-01
Listed here are significant publications and presentations of the Space Science Laboratory during the period January 1 to December 31, 1991. Entries are categorized according to NASA Reports (arranged by report number), Open Literature, and Presentations (arranged alphabetically by title). Also included is an appendix listing preprints issued by the laboratory during this reporting period.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Virginia L. Finley
The results of the 2000 environmental surveillance and monitoring program for the Princeton Plasma Physics Laboratory (PPPL) are presented and discussed. The purpose of this report is to provide the U.S. Department of Energy and the public with information on the level of radioactive and nonradioactive pollutants (if any) that are added to the environment as a result of PPPL's operations. The report also summarizes environmental initiatives, assessments, and programs that were undertaken in 2000. The Princeton Plasma Physics Laboratory has engaged in fusion energy research since 1951. The long-range goal of the U.S. Magnetic Fusion Energy Research Program ismore » to create innovations to make fusion power a practical reality -- an alternative energy source. The year 2000 marked the second year of National Spherical Torus Experiment (NSTX) operations and Tokamak Fusion Test Reactor (TFTR) dismantlement and deconstruction activities. A collaboration among fourteen national laboratories, universities, and research institutions, the NSTX is a major element in the U.S. Fusion Energy Sciences Program. It has been designed to test the physics principles of spherical torus (ST) plasmas. The ST concept could play an important role in the development of smaller, more economical fusion power plants. With its completion within budget and ahead of its target schedule, NSTX first plasma occurred on February 12, 1999. In 2000, PPPL's radiological environmental monitoring program measured tritium in the air at on-site and off-site sampling stations. PPPL is capable of detecting small changes in the ambient levels of tritium by using highly sensitive monitors. The operation of an in-stack monitor located on D-site is a requirement of the National Emission Standard for Hazardous Air Pollutants (NESHAPs) regulations with limits set by the Environmental Protection Agency (EPA). Also included in PPPL's radiological environmental monitoring program, are precipitation, surface, ground, a nd waste water monitoring. Groundwater investigations continued under a voluntary agreement with the New Jersey Department of Environmental Protection. PPPL monitored for the presence of nonradiological contaminants, mainly volatile organic compounds (components of degreasing solvents). Monitoring revealed the presence of low levels of volatile organic compounds in an area adjacent to PPPL. Also, PPPL's radiological monitoring program characterized the ambient, background levels of tritium in the environment and from the D-site stack; the data are presented in this report.« less
Ezekiel, C.N.; Udom, I.E.; Frisvad, J.C.; Adetunji, M.C.; Houbraken, J.; Fapohunda, S.O.; Samson, R.A.; Atanda, O.O.; Agi-Otto, M.C.; Onashile, O.A.
2014-01-01
Sixteen fonio millet and 17 sesame samples were analysed for incidence of moulds, especially aflatoxigenic Aspergillus species, in order to determine the safety of both crops to consumers, and to correlate aflatoxin levels in the crops with levels produced by toxigenic isolates on laboratory medium. Diverse moulds including Alternaria, Aspergillus, Cercospora, Fusarium, Mucor, Penicillium, Rhizopus and Trichoderma were isolated. Aspergillus was predominantly present in both crops (46–48%), and amongst the potentially aflatoxigenic Aspergillus species, A. flavus recorded the highest incidence (68% in fonio millet; 86% in sesame kernels). All A. parvisclerotigenus isolates produced B and G aflatoxins in culture while B aflatoxins were produced by only 39% and 20% of A. flavus strains isolated from the fonio millet and sesame kernels, respectively. Aflatoxin concentrations in fonio millet correlated inversely (r = −0.55; p = 0.02) with aflatoxin levels produced by toxigenic isolates on laboratory medium, but no correlation was observed in the case of the sesame samples. Both crops, especially sesame, may not be suitable substrates for aflatoxin biosynthesis. This is the first report on A. parvisclerotigenus in sesame. PMID:24772370
Benschop, Corina C G; Connolly, Edward; Ansell, Ricky; Kokshoorn, Bas
2017-01-01
The interpretation of complex DNA profiles may differ between laboratories and reporting officers, which can lead to discrepancies in the final reports. In this study, we assessed the intra and inter laboratory variation in DNA mixture interpretation for three European ISO17025-accredited laboratories. To this aim, 26 reporting officers analyzed five sets of DNA profiles. Three main aspects were considered: 1) whether the mixed DNA profiles met the criteria for comparison to a reference profile, 2) the actual result of the comparison between references and DNA profiling data and 3) whether the weight of the DNA evidence could be assessed. Similarity in answers depended mostly on the complexity of the tasks. This study showed less variation within laboratories than between laboratories which could be the result of differences between internal laboratory guidelines and methods and tools available. Results show the profile types for which the three laboratories report differently, which informs indirectly on the complexity threshold the laboratories employ. Largest differences between laboratories were caused by the methods available to assess the weight of the DNA evidence. This exercise aids in training forensic scientists, refining laboratory guidelines and explaining differences between laboratories in court. Undertaking more collaborative exercises in future may stimulate dialog and consensus regarding interpretation. For training purposes, DNA profiles of the mixed stains and questioned references are made available. Copyright © 2016 The Chartered Society of Forensic Sciences. Published by Elsevier Ireland Ltd. All rights reserved.
2012-04-06
Biochemical genetic testing and newborn screening are essential laboratory services for the screening, detection, diagnosis, and monitoring of inborn errors of metabolism or inherited metabolic disorders. Under the Clinical Laboratory Improvement Amendments of 1988 (CLIA) regulations, laboratory testing is categorized on the basis of the level of testing complexity as either waived (i.e., from routine regulatory oversight) or nonwaived testing (which includes tests of moderate and high complexity). Laboratories that perform biochemical genetic testing are required by CLIA regulations to meet the general quality systems requirements for nonwaived testing and the personnel requirements for high-complexity testing. Laboratories that perform public health newborn screening are subject to the same CLIA regulations and applicable state requirements. As the number of inherited metabolic diseases that are included in state-based newborn screening programs continues to increase, ensuring the quality of performance and delivery of testing services remains a continuous challenge not only for public health laboratories and other newborn screening facilities but also for biochemical genetic testing laboratories. To help ensure the quality of laboratory testing, CDC collaborated with the Centers for Medicare & Medicaid Services, the Food and Drug Administration, the Health Resources and Services Administration, and the National Institutes of Health to develop guidelines for laboratories to meet CLIA requirements and apply additional quality assurance measures for these areas of genetic testing. This report provides recommendations for good laboratory practices that were developed based on recommendations from the Clinical Laboratory Improvement Advisory Committee, with additional input from the Secretary's Advisory Committee on Genetics, Health, and Society; the Secretary's Advisory Committee on Heritable Disorders in Newborns and Children; and representatives of newborn screening laboratories. The recommended practices address the benefits of using a quality management system approach, factors to consider before introducing new tests, establishment and verification of test performance specifications, the total laboratory testing process (which consists of the preanalytic, analytic, and postanalytic phases), confidentiality of patient information and test results, and personnel qualifications and responsibilities for laboratory testing for inherited metabolic diseases. These recommendations are intended for laboratories that perform biochemical genetic testing to improve the quality of laboratory services and for newborn screening laboratories to ensure the quality of laboratory practices for inherited metabolic disorders. These recommendations also are intended as a resource for medical and public health professionals who evaluate laboratory practices, for users of laboratory services to facilitate their collaboration with newborn screening systems and use of biochemical genetic tests, and for standard-setting organizations and professional societies in developing future laboratory quality standards and practice recommendations. This report complements Good Laboratory Practices for Molecular Genetic Testing for Heritable Diseases and Conditions (CDC. Good laboratory practices for molecular genetic testing for heritable diseases and conditions. MMWR 2009;58 [No. RR-6]) to provide guidance for ensuring and improving the quality of genetic laboratory services and public health outcomes. Future recommendations for additional areas of genetic testing will be considered on the basis of continued monitoring and evaluation of laboratory practices, technology advancements, and the development of laboratory standards and guidelines.
1992-12-28
Research Program Starfire Optical Range, Phillips Laboratory /LITE Kirtland Air Force Base, Albuquerque, NM 87117 Sponsored by: Air ... Phillips Laboratory Sponsored by: Air Force Office of Scientific Research Kirtland Air Force Base, Albuquerque, New Mexico September, 1992 18-1 PROGRESS...Report for: Summer Research Program Phillips Laboratory Sponsored by: Air
1992-12-28
Phillips Laboratory Kirtland Air Force Base NM 87117-6008 Sponsored by: Air Force Office of Scientific Research Bolling Air Force Base...Zindel, D.: 1963, Z. Astrophys. 57, 82. 29-13 FINAL REPORT SUMMER FACULTY RESEARCH PROGRAM AT PHILLIPS LABORATORY KIRTLAND AIR FORCE BASE...Program Phillips Laboratory Sponsored by: Air Force Office of Scientific
United States Air Force Summer Research Program -- 1993. Volume 8. Phillips Laboratory
1993-12-01
Research Program Phillips Laboratory Kirtland Air Force Base Albuquerque. New Mexico Sponsored by...Best Available Copy UNITED STATES AIR FORCE SUMMER RESEARCH PROGRAM -- 1993 SUMMER RESEARCH PROGRAM FINAL REPORTS VOLUME 8 PHILLIPS LABORATORY ...Alabama Box 870344 Tuscaloosa, AL 35487-0344 Final Report for: Graduate Student Research Program Phillips Laboratory , Hanscom AFB Sponsored by: Air
Ho, Bella; Ho, Eric
2012-01-01
Introduction: ISO 15189 was a new standard published in 2003 for accrediting medical laboratories. We believe that some requirements of the ISO 15189 standard are especially difficult to meet for majority of laboratories. The aim of this article was to present the frequency of nonconformities to requirements of the ISO 15189 accreditation standard, encountered during the assessments of medical laboratories in Hong Kong, during 2004 to 2009. Materials and methods: Nonconformities reported in assessments based on ISO 15189 were analyzed in two periods – from 2004 to 2006 and in 2009. They are categorized according to the ISO 15189 clause numbers. The performance of 27 laboratories initially assessed between 2004 and 2006 was compared to their performance in the second reassessment in 2009. Results: For management requirements, nonconformities were most frequently reported against quality management system, quality and technical records and document control; whereas for technical requirements, they were reported against examination procedures, equipment, and assuring quality of examination procedures. There was no major difference in types of common nonconformities reported in the two study periods. The total number of nonconformities reported in the second reassessment of 27 laboratories in 2009 was almost halved compared to their initial assessments. The number of significant nonconformities per laboratory significantly decreased (P = 0.023). Conclusion: Similar nonconformities were reported in the two study periods though the frequency encountered decreased. The significant decrease in number of significant nonconformities encountered in the same group of laboratories in the two periods substantiated that ISO15189 contributed to quality improvement of accredited laboratories. PMID:22838190
Ho, Bella; Ho, Eric
2012-01-01
ISO 15189 was a new standard published in 2003 for accrediting medical laboratories. We believe that some requirements of the ISO 15189 standard are especially difficult to meet for majority of laboratories. The aim of this article was to present the frequency of nonconformities to requirements of the ISO 15189 accreditation standard, encountered during the assessments of medical laboratories in Hong Kong, during 2004 to 2009. Nonconformities reported in assessments based on ISO 15189 were analyzed in two periods - from 2004 to 2006 and in 2009. They are categorized according to the ISO 15189 clause numbers. The performance of 27 laboratories initially assessed between 2004 and 2006 was compared to their performance in the second reassessment in 2009. For management requirements, nonconformities were most frequently reported against quality management system, quality and technical records and document control; whereas for technical requirements, they were reported against examination procedures, equipment, and assuring quality of examination procedures. There was no major difference in types of common nonconformities reported in the two study periods. The total number of nonconformities reported in the second reassessment of 27 laboratories in 2009 was almost halved compared to their initial assessments. The number of significant nonconformities per laboratory significantly decreased (P = 0.023). Similar nonconformities were reported in the two study periods though the frequency encountered decreased. The significant decrease in number of significant nonconformities encountered in the same group of laboratories in the two periods substantiated that 15015189 contributed to quality improvement of accredited laboratories.
Garrett, Tiana A; Davies-Cole, John; Furness, Bruce
2015-08-01
In the District of Columbia (DC), Neisseria gonorrhoeae (gonorrhea) infections accounted for more than 25% of 9321 incident sexually transmitted infections reported in 2011; untreated infections can lead to reproductive complications and a higher risk for HIV transmission. In DC, limited capacity to measure the prevalence of antibiotic-resistant N. gonorrhoeae is available; culture-based antibiotic susceptibility testing (AST) is needed to monitor antimicrobial resistance. We examined the capacity of laboratories that report to the DC Department of Health to perform AST for ongoing surveillance of antibiotic-resistant N. gonorrhoeae and to identify suspected treatment failures. We created a survey about diagnostic methods for gonorrhea testing and identified 33 laboratories that reported gonorrhea results to Department of Health in 2007 to 2012. Laboratories were assessed for use of bacterial culture or nucleic acid amplification testing (NAAT) for gonorrhea testing, prevalence of AST on gonorrhea-positive cultures, and types of antibiotics tested during AST. We estimated the prevalence of laboratory practices on the basis of self-report by staff. Nineteen (58%) laboratories completed the survey, representing 92% of the gonorrhea reporting. Seventeen (89%) of 19 laboratories conducted testing by culture; only 6 (35%) performed AST; 79% performed NAAT. Barriers to AST included longer completion times and limited number of provider requests for AST. Commercial laboratories (32%) were more likely to conduct both culture and NAAT, compared with health care facilities (11%). We report a low prevalence of laboratories performing AST because of multiple barriers. State-specific strategies addressing these barriers are needed to improve detection of antibiotic-resistant gonorrhea stains circulating among the population.
ORNLs Laboratory Directed Research and Development Program FY 2009 Annual Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
2010-03-01
The Laboratory Directed Research and Development (LDRD) program at Oak Ridge National Laboratory (ORNL) reports its status to the U.S. Department of Energy (DOE) in March of each year. The program operates under the authority of DOE Order 413.2B, “Laboratory Directed Research and Development” (April 19, 2006), which establishes DOE’s requirements for the program while providing the Laboratory Director broad flexibility for program implementation. LDRD funds are obtained through a charge to all Laboratory programs. This report includes summaries all ORNL LDRD research activities supported during FY 2009. The associated FY 2009 ORNL LDRD Self-Assessment (ORNL/PPA-2010/2) provides financial data andmore » an internal evaluation of the program’s management process.« less
ORNLs Laboratory Directed Research and Development Program FY 2013 Annual Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
2014-03-01
The Laboratory Directed Research and Development (LDRD) program at Oak Ridge National Laboratory (ORNL) reports its status to the US Department of Energy (DOE) in March of each year. The program operates under the authority of DOE Order 413.2B, “Laboratory Directed Research and Development” (April 19, 2006), which establishes DOE’s requirements for the program while providing the Laboratory Director broad flexibility for program implementation. LDRD funds are obtained through a charge to all Laboratory programs. This report includes summaries of all ORNL LDRD research activities supported during FY 2013. The associated FY 2013 ORNL LDRD Self-Assessment (ORNL/PPA-2014/2) provides financial datamore » and an internal evaluation of the program’s management process.« less
Laboratory Directed Research and Development Program FY 2006 Annual Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sjoreen, Terrence P
2007-04-01
The Oak Ridge National Laboratory (ORNL) Laboratory Directed Research and Development (LDRD) Program reports its status to the US Departmental of Energy (DOE) in March of each year. The program operates under the authority of DOE Order 413.2B, 'Laboratory Directed Research and Development' (April 19, 2006), which establishes DOE's requirements for the program while providing the Laboratory Director broad flexibility for program implementation. LDRD funds are obtained through a charge to all Laboratory programs. This report includes summaries all ORNL LDRD research activities supported during FY 2006. The associated FY 2006 ORNL LDRD Self-Assessment (ORNL/PPA-2007/2) provides financial data about themore » FY 2006 projects and an internal evaluation of the program's management process.« less
ORNLs Laboratory Directed Research and Development Program FY 2008 Annual Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
2009-03-01
The Oak Ridge National Laboratory (ORNL) Laboratory Directed Research and Development (LDRD) Program reports its status to the U.S. Department of Energy (DOE) in March of each year. The program operates under the authority of DOE Order 413.2B, “Laboratory Directed Research and Development” (April 19, 2006), which establishes DOE’s requirements for the program while providing the Laboratory Director broad flexibility for program implementation. LDRD funds are obtained through a charge to all Laboratory programs. This report includes summaries all ORNL LDRD research activities supported during FY 2008. The associated FY 2008 ORNL LDRD Self-Assessment (ORNL/PPA-2008/2) provides financial data and anmore » internal evaluation of the program’s management process.« less
ORNLs Laboratory Directed Research and Development Program FY 2012 Annual Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
2013-03-01
The Laboratory Directed Research and Development (LDRD) program at Oak Ridge National Laboratory (ORNL) reports its status to the US Department of Energy (DOE) in March of each year. The program operates under the authority of DOE Order 413.2B, “Laboratory Directed Research and Development” (April 19, 2006), which establishes DOE’s requirements for the program while providing the Laboratory Director broad flexibility for program implementation. LDRD funds are obtained through a charge to all Laboratory programs. This report includes summaries of all ORNL LDRD research activities supported during FY 2012. The associated FY 2012 ORNL LDRD Self-Assessment (ORNL/PPA-2012/2) provides financial datamore » and an internal evaluation of the program’s management process.« less
Namatovu, Alice; Wekesa, Sabenzia Nabalayo; Tjørnehøj, Kirsten; Dhikusooka, Moses Tefula; Muwanika, Vincent B; Siegsmund, Hans Redlef; Ayebazibwe, Chrisostom
2013-01-24
Accurate diagnosis is pertinent to any disease control programme. If Eastern Africa is to work towards control of foot-and-mouth disease (FMD) using the Progressive Control Pathway for FMD (PCP-FMD) as a tool, then the capacity of national reference laboratories (NRLs) mandated to diagnose FMD should match this task. This study assessed the laboratory capacity of 14 NRLs of the Eastern Africa Region Laboratory Network member countries using a semi-structured questionnaire and retrospective data from the World Reference Laboratory for FMD annual reports and Genbank® through National Centre for Biotechnology Information for the period 2006-2010. The questionnaire response rate was 13/14 (93%). Twelve out of the 13 countries/regions had experienced at least one outbreak in the relevant five year period. Only two countries (Ethiopia and Kenya) had laboratories at biosecurity level 3 and only three (Ethiopia, Kenya and Sudan) had identified FMD virus serotypes for all reported outbreaks. Based on their own country/region assessment, 12/13 of these countries /regions were below stage 3 of the PCP-FMD. Quarantine (77%) and vaccination (54%) were the major FMD control strategies employed. The majority (12/13) of the NRLs used serological techniques to diagnose FMD, seven used antigen ELISA and three of these (25%) also used molecular techniques which were the tests most frequently requested from collaborating laboratories by the majority (69%) of the NRLs. Only 4/13 (31%) participated in proficiency testing for FMD. Four (31%) laboratories had no quality management systems (QMS) in place and where QMS existed it was still deficient, thus, none of the laboratories had achieved accreditation for FMD diagnosis. This study indicates that FMD diagnostic capacity in Eastern Africa is still inadequate and largely depends on antigen and antibody ELISAs techniques undertaken by the NRLs. Hence, for the region to progress on the PCP-FMD, there is need to: implement regional control measures, improve the serological diagnostic test performance and laboratory capacity of the NRLs (including training of personnel as well as upgrading of equipment and methods, especially strengthening the molecular diagnostic capacity), and to establish a regional reference laboratory to enforce QMS and characterization of FMD virus containing samples.
2013-01-01
Background Accurate diagnosis is pertinent to any disease control programme. If Eastern Africa is to work towards control of foot-and-mouth disease (FMD) using the Progressive Control Pathway for FMD (PCP-FMD) as a tool, then the capacity of national reference laboratories (NRLs) mandated to diagnose FMD should match this task. This study assessed the laboratory capacity of 14 NRLs of the Eastern Africa Region Laboratory Network member countries using a semi-structured questionnaire and retrospective data from the World Reference Laboratory for FMD annual reports and Genbank® through National Centre for Biotechnology Information for the period 2006–2010. Results The questionnaire response rate was 13/14 (93%). Twelve out of the 13 countries/regions had experienced at least one outbreak in the relevant five year period. Only two countries (Ethiopia and Kenya) had laboratories at biosecurity level 3 and only three (Ethiopia, Kenya and Sudan) had identified FMD virus serotypes for all reported outbreaks. Based on their own country/region assessment, 12/13 of these countries /regions were below stage 3 of the PCP-FMD. Quarantine (77%) and vaccination (54%) were the major FMD control strategies employed. The majority (12/13) of the NRLs used serological techniques to diagnose FMD, seven used antigen ELISA and three of these (25%) also used molecular techniques which were the tests most frequently requested from collaborating laboratories by the majority (69%) of the NRLs. Only 4/13 (31%) participated in proficiency testing for FMD. Four (31%) laboratories had no quality management systems (QMS) in place and where QMS existed it was still deficient, thus, none of the laboratories had achieved accreditation for FMD diagnosis. Conclusions This study indicates that FMD diagnostic capacity in Eastern Africa is still inadequate and largely depends on antigen and antibody ELISAs techniques undertaken by the NRLs. Hence, for the region to progress on the PCP-FMD, there is need to: implement regional control measures, improve the serological diagnostic test performance and laboratory capacity of the NRLs (including training of personnel as well as upgrading of equipment and methods, especially strengthening the molecular diagnostic capacity), and to establish a regional reference laboratory to enforce QMS and characterization of FMD virus containing samples. PMID:23347795
Nakhleh, Raouf E; Souers, Rhona; Ruby, Stephen G
2008-11-01
There are multiple elements that can be measured to assess the quality of a surgical pathology laboratory. Overall customer satisfaction is an excellent "global" measure, because it highlights the unique insight of laboratory performance from the users' perspective. To measure customer satisfaction with surgical pathology reports. This study was based on a subscription Q-Tracks study. Voluntary participants were asked to distribute and collect a minimum of 25 surveys per quarter from their clients. Four parameters were graded, which included overall satisfaction, report turnaround time (TAT), completeness, and style on a scale of 1 (poor) to 5 (excellent). Each laboratory submitted quarterly data to the College of American Pathologists, where the data were tabulated and analyzed. Each laboratory could compare their performance in all 4 measures against the entire cohort or a selected subgroup of laboratories. Overall customer satisfaction with surgical pathology reports and 3 subcategories of report TAT, completeness, and style were the main outcome measures. This study ran during 2004 and 2005, with 41 and 33 participant laboratories, respectively. The median score for overall satisfaction, TAT, completeness, and style were 4.57, 4.31, 4.62, and 4.64 in 2004, and 4.64, 4.56, 4.65, and 4.68 in 2005, respectively. Most laboratories reported results for 4 quarters or fewer. There was no statistically significant change in overall satisfaction over time. Overall satisfaction scores for surgical pathology reports as well as satisfaction with report TAT, completeness, and style were high. Report TAT received the lowest scores of all parameters.
Radionuclides in ground water at the Idaho National Engineering Laboratory, Idaho
Knobel, LeRoy L.; Mann, Larry J.
1988-01-01
Sampling for radionuclides in groundwater was conducted at the Idaho National Engineering Laboratory during September to November 5 1987. Water samples from 80 wells that obtain water from the Snake River Plain aquifer and 1 well that obtains water from a shallow, discontinuous perched-water body at the Radioactive Waste Management Complex were collected and analyzed for tritium, strontium-90, plutonium-238, plutonium-239, -240 (undivided), americium-241, cesium-137, cobalt-60, and potassium-40--a naturally occurring radionuclide. The groundwater samples were analyzed at the Idaho National Engineering Laboratory in Idaho. Tritium and strontium-90 concentrations ranged from below the reporting level to 80.6 +/-0.000005 and 193 +/-5x10 to the minus eight micrograms Ci/ml, respectively. Water from a disposal well at Test Area North--which has not been used to dispose of waste water since September 1972--contained 122 +/-9x10 to the minus eleven micrograms Ci/ml of plutonium-238, 500 +/-20x10 to the minus eleven of plutonium-239, -240 (undivided), 21 +/-4x10 to the minus eleven micrograms Ci/ml of americium-241, and 750 +/-20x10 to the minus eight micrograms Ci/ml cesium-137; the presence of these radionuclides was verified by resampling and reanalysis. The disposal well had 8.9 +/-0.0000009 micrograms Ci/ml of cobalt-60 on October 28, 1987, but cobalt-60 was not detected when the well was resampled on January 11, 1988. Potassium-40 concentrations were less than the reporting level in all wells. (USGS)
Whole-cell luminescence biosensor-based lab-on-chip integrated system for water toxicity analysis
NASA Astrophysics Data System (ADS)
Rabner, Arthur; Belkin, Shimshon; Rozen, Rachel; Shacham, Yosi
2006-01-01
A novel water chemical toxin sensor has been successfully developed and evaluated as a working portable laboratory prototype. This sensor relies on a disposable plastic biochip prepared with a 4x4 micro-laboratory (μLab) chambers array of Escherichia coli reporter cells and micro-fluidic channels for liquids translocation. Each bacterial strain has been genetically modified into a bioluminescent reporter that responds to a pre-determined class of chemical agents. When challenged with a water sample containing a toxic chemical, the sensor responds with an increased bioluminescent signal from the biochip that is monitored over time. The signal is received by a motorized photomultiplier-based analyzer and interpreted by signal processing software. We have performed several levels of analysis: (i) the change in the bioluminescent signal from the sensor bacteria serves as a rapid indication for the presence of toxic chemicals in the water sample; (ii) the intensity of the change indicates the toxin concentration level; and (iii) the pattern of the responses for the different members of the bacterial panel on the biochip characterizes the biological origin of the toxin. The analyzer contains housing mechanics, electro-optics for signal acquisition, motorized readout calibration accessories, hydro-pneumatics modules for water sample translocation into biochip micro laboratories, electronics for overall control and communication with the host computer. This prototype has a demonstrated sensitivity for broad classes of water-borne toxic chemicals including naladixic acid (a model genotoxic agent), botulinum and acetylcholine esterase inhibitors. This work has initiated an investigation of a novel handheld field-deployable Water Toxicity Analysis (WTA) device.
Laboratory Directed Research and Development FY 2000 Annual Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Al-Ayat, R
This Annual Report provides an overview of the FY2000 Laboratory Directed Research and Development (LDRD) Program at Lawrence Livermore National Laboratory (LLNL) and presents a summary of the results achieved by each project during the year.
The quality of veterinary in-clinic and reference laboratory biochemical testing.
Rishniw, Mark; Pion, Paul D; Maher, Tammy
2012-03-01
Although evaluation of biochemical analytes in blood is common in veterinary practice, studies assessing the global quality of veterinary in-clinic and reference laboratory testing have not been reported. The aim of this study was to assess the quality of biochemical testing in veterinary laboratories using results obtained from analyses of 3 levels of assayed quality control materials over 5 days. Quality was assessed by comparison of calculated total error with quality requirements, determination of sigma metrics, use of a quality goal index to determine factors contributing to poor performance, and agreement between in-clinic and reference laboratory mean results. The suitability of in-clinic and reference laboratory instruments for statistical quality control was determined using adaptations from the computerized program, EZRules3. Reference laboratories were able to achieve desirable quality requirements more frequently than in-clinic laboratories. Across all 3 materials, > 50% of in-clinic analyzers achieved a sigma metric ≥ 6.0 for measurement of 2 analytes, whereas > 50% of reference laboratory analyzers achieved a sigma metric ≥ 6.0 for measurement of 6 analytes. Expanded uncertainty of measurement and ± total allowable error resulted in the highest mean percentages of analytes demonstrating agreement between in-clinic and reference laboratories. Owing to marked variation in bias and coefficient of variation between analyzers of the same and different types, the percentages of analytes suitable for statistical quality control varied widely. These findings reflect the current state-of-the-art with regard to in-clinic and reference laboratory analyzer performance and provide a baseline for future evaluations of the quality of veterinary laboratory testing. © 2012 American Society for Veterinary Clinical Pathology.
Le, Margaret; Flores, David; May, Danica; Gourley, Eric; Nangia, Ajay K
2016-05-01
The evaluation and management of male hypogonadism should be based on symptoms and on serum testosterone levels. Diagnostically this relies on accurate testing and reference values. Our objective was to define the distribution of reference values and assays for free and total testosterone by clinical laboratories in the United States. Upper and lower reference values, assay methodology and source of published reference ranges were obtained from laboratories across the country. A standardized survey was reviewed with laboratory staff via telephone. Descriptive statistics were used to tabulate results. We surveyed a total of 120 laboratories in 47 states. Total testosterone was measured in house at 73% of laboratories. At the remaining laboratories studies were sent to larger centralized reference facilities. The mean ± SD lower reference value of total testosterone was 231 ± 46 ng/dl (range 160 to 300) and the mean upper limit was 850 ± 141 ng/dl (range 726 to 1,130). Only 9% of laboratories where in-house total testosterone testing was performed created a reference range unique to their region. Others validated the instrument recommended reference values in a small number of internal test samples. For free testosterone 82% of laboratories sent testing to larger centralized reference laboratories where equilibrium dialysis and/or liquid chromatography with mass spectrometry was done. The remaining laboratories used published algorithms to calculate serum free testosterone. Reference ranges for testosterone assays vary significantly among laboratories. The ranges are predominantly defined by limited population studies of men with unknown medical and reproductive histories. These poorly defined and variable reference values, especially the lower limit, affect how clinicians determine treatment. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Environmental surveillance at Los Alamos during 2005
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2006-09-30
Environmental Surveillance at Los Alamos reports are prepared annually by the Los Alamos National Laboratory (LANL or the Laboratory) environmental organization, as required by US Department of Energy Order 5400.1, General Environmental Protection Program, and US Department of Energy Order 231.IA, Environment, Safety, and Health Reporting. These annual reports summarize environmental data that are used to determine compliance with applicable federal, state, and local environmental laws and regulations, executive orders, and departmental policies. Additional data, beyond the minimum required, are also gathered and reported as part of the Laboratory's efforts to ensure public safety and to monitor environmental quality atmore » and near the Laboratory. Chapter 1 provides an overview of the Laboratory's major environmental programs. Chapter 2 reports the Laboratory's compliance status for 2005. Chapter 3 provides a summary of the maximum radiological dose the public and biota populations could have potentially received from Laboratory operations. The environmental surveillance and monitoring data are organized by environmental media (Chapter 4, Air; Chapters 5 and 6, Water and Sediments; Chapter 7, Soils; and Chapter 8, Foodstuffs and Biota) in a format to meet the needs of a general and scientific audience. Chapter 9, new for this year, provides a summary of the status of environmental restoration work around LANL. A glossary and a list ofacronyms and abbreviations are in the back of the report. Appendix A explains the standards for environmental contaminants, Appendix B explains the units of measurements used in this report, Appendix C describes the Laboratory's technical areas and their associated programs, and Appendix D provides web links to more information.« less
Site Environmental Report for 2006. Volume I, Environment, Health, and Safety Division
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2007-09-30
Each year, Ernest Orlando Lawrence Berkeley National Laboratory prepares an integrated report on its environmental programs to satisfy the requirements of United States Department of Energy Order 231.1A, Environment, Safety, and Health Reporting.1 The Site Environmental Report for 2006 summarizes Berkeley Lab’s environmental management performance, presents environmental monitoring results, and describes significant programs for calendar year 2006. (Throughout this report, Ernest Orlando Lawrence Berkeley National Laboratory is referred to as “Berkeley Lab,” “the Laboratory,” “Lawrence Berkeley National Laboratory,” and “LBNL.”) The report is separated into two volumes. Volume I is organized into an executive summary followed by six chapters thatmore » contain an overview of the Laboratory, a discussion of the Laboratory’s environmental management system, the status of environmental programs, and summarized results from surveillance and monitoring activities. Volume II contains individual data results from surveillance and monitoring activities.« less
Site Environmental Report for 2004. Volume 1, Environment, Health, and Safety Division
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2005-09-30
Each year, Ernest Orlando Lawrence Berkeley National Laboratory prepares an integrated report on its environmental programs to satisfy the requirements of United States Department of Energy Order 231.1A, Environment, Safety, and Health Reporting.1 The Site Environmental Report for 2004 summarizes Berkeley Lab’s environmental management performance, presents environmental monitoring results, and describes significant programs for calendar year 2004. (Throughout this report, Ernest Orlando Lawrence Berkeley National Laboratory is referred to as “Berkeley Lab,” “the Laboratory,” “Lawrence Berkeley National Laboratory,” and “LBNL.”) The report is separated into two volumes. Volume I contains an overview of the Laboratory, the status of environmental programs,more » and summarized results from surveillance and monitoring activities. Volume II contains individual data results from these activities. This year, the Site Environmental Report was distributed by releasing it on the Web from the Berkeley Lab Environmental Services Group (ESG) home page, which is located at http://www.lbl.gov/ehs/esg/. Many of the documents cited in this report also are accessible from the ESG Web page. CD and printed copies of this Site Environmental Report are available upon request.« less
EML Gamma Spectrometry Data Evaluation Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Decker, Karin M.
1998-02-28
This report represents the results of the analyses for the second EML Gamma Spectrometry Data Evaluation Program (August 1997). A calibration spectrum, a background spectrum and three sample spectra were included for each software format as part of the evaluation. The calibration spectrum contained nuclides covering the range from 59.5 keV to 1836 keV. The participants were told fallout and fission product nuclides as well as naturally occurring nuclides could be present. The samples were designed to test the detection and quantification of very low levels of nuclides and the ability of the software and user to properly resolve multiplets.more » The participants were asked to report values and uncertainties as Becquerel per sample with no decay correction. Twenty-nine sets of results were reported from a total of 70 laboratories who received the spectra. The percentage of the results within 1 F of the expected value was 76, 67, and 55 for samples 1, 2, and 3, respectively. From all three samples, 12% of the results were more than 3 F from the expected value. Sixty-two nuclides out of a total of 580 expected results were not reported for the three samples. Sixty percent of these false negatives were due to nuclides which were present at the minimum detectable activity level. There were 53 false positives reported with 60% of the responses due to problems with background subtraction. The results indicate that the Program is beneficial to the participating laboratories in that it provides them with analysis problems that are difficult to create with spiked samples due to the unavailability of many nuclides and the short half-lives of others. EML will continue its annual distribution, the third is to be held in March 1999.« less
Probing bulk physics in the 5/2 fractional quantum Hall effect using the Corbino geometry
NASA Astrophysics Data System (ADS)
Schmidt, Benjamin; Bennaceur, Keyan; Bilodeau, Simon; Gaucher, Samuel; Lilly, Michael; Reno, John; Pfeiffer, Loren; West, Ken; Reulet, Bertrand; Gervais, Guillaume
We present two- and four-point Corbino geometry transport measurements in the second Landau level in GaAs/AlGaAs heterostructures. By avoiding edge transport, we are able to directly probe the physics of the bulk quasiparticles in fractional quantum Hall (FQH) states including 5/2. Our highest-quality sample shows stripe and bubble phases in high Landau levels, and most importantly well-resolved FQH minima in the second Landau level. We report Arrhenius-type fits to the activated conductance, and find that σ0 agrees well with theory and existing Hall geometry data in the first Landau level, but not in the second Landau level. We will discuss the advantages the Corbino geometry could bring to various experiments designed to detect the non-Abelian entropy at 5/2, and our progress towards realizing those schemes. The results of these experiments could complement interferometry and other edge-based measurements by providing direct evidence for non-Abelian behaviour of the bulk quasiparticles. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under Contract DE-AC04-94AL8500.
Utility of repeat testing of critical values: a Q-probes analysis of 86 clinical laboratories.
Lehman, Christopher M; Howanitz, Peter J; Souers, Rhona; Karcher, Donald S
2014-06-01
A common laboratory practice is to repeat critical values before reporting the test results to the clinical care provider. This may be an unnecessary step that delays the reporting of critical test results without adding value to the accuracy of the test result. To determine the proportions of repeated chemistry and hematology critical values that differ significantly from the original value as defined by the participating laboratory, to determine the threshold differences defined by the laboratory as clinically significant, and to determine the additional time required to analyze the repeat test. Participants prospectively reviewed critical test results for 4 laboratory tests: glucose, potassium, white blood cell count, and platelet count. Participants reported the following information: initial and repeated test result; time initial and repeat results were first known to laboratory staff; critical result notification time; if the repeat result was still a critical result; if the repeat result was significantly different from the initial result, as judged by the laboratory professional or policy; significant difference threshold, as defined by the laboratory; the make and model of the instrument used for primary and repeat testing. Routine, repeat analysis of critical values is a common practice. Most laboratories did not formally define a significant difference between repeat results. Repeated results were rarely considered significantly different. Median repeated times were at least 17 to 21 minutes for 10% of laboratories. Twenty percent of laboratories reported at least 1 incident in the last calendar year of delayed result reporting that clinicians indicated had adversely affected patient care. Routine repeat analysis of automated chemistry and hematology critical values is unlikely to be clinically useful and may adversely affect patient care.