Sample records for laboratory scale samples

  1. The small-scale treatability study sample exemption

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coalgate, J.

    1991-01-01

    In 1981, the Environmental Protection Agency (EPA) issued an interim final rule that conditionally exempted waste samples collected solely for the purpose of monitoring or testing to determine their characteristics or composition'' from RCRA Subtitle C hazardous waste regulations. This exemption (40 CFR 261.4(d)) apples to the transportation of samples between the generator and testing laboratory, temporary storage of samples at the laboratory prior to and following testing, and storage at a laboratory for specific purposes such as an enforcement action. However, the exclusion did not include large-scale samples used in treatability studies or other testing at pilot plants ormore » other experimental facilities. As a result of comments received by the EPA subsequent to the issuance of the interim final rule, the EPA reopened the comment period on the interim final rule on September 18, 1987, and specifically requested comments on whether or not the sample exclusion should be expanded to include waste samples used in small-scale treatability studies. Almost all responders commented favorably on such a proposal. As a result, the EPA issued a final rule (53 FR 27290, July 19, 1988) conditionally exempting waste samples used in small-scale treatability studies from full regulation under Subtitle C of RCRA. The question of whether or not to extend the exclusion to larger scale as proposed by the Hazardous Waste Treatment Council was deferred until a later date. This information Brief summarizes the requirements of the small-scale treatability exemption.« less

  2. Who Should Join the Environmental Response Laboratory Network

    EPA Pesticide Factsheets

    Laboratories that analyze biological samples, chemical warfare agents, radiological, or toxic industrial chemical samples can join the ERLN. Members make up a critical infrastructure that delivers data necessary for responses to large scale emergencies.

  3. Comparing and Combining Data across Multiple Sources via Integration of Paired-sample Data to Correct for Measurement Error

    PubMed Central

    Huang, Yunda; Huang, Ying; Moodie, Zoe; Li, Sue; Self, Steve

    2014-01-01

    Summary In biomedical research such as the development of vaccines for infectious diseases or cancer, measures from the same assay are often collected from multiple sources or laboratories. Measurement error that may vary between laboratories needs to be adjusted for when combining samples across laboratories. We incorporate such adjustment in comparing and combining independent samples from different labs via integration of external data, collected on paired samples from the same two laboratories. We propose: 1) normalization of individual level data from two laboratories to the same scale via the expectation of true measurements conditioning on the observed; 2) comparison of mean assay values between two independent samples in the Main study accounting for inter-source measurement error; and 3) sample size calculations of the paired-sample study so that hypothesis testing error rates are appropriately controlled in the Main study comparison. Because the goal is not to estimate the true underlying measurements but to combine data on the same scale, our proposed methods do not require that the true values for the errorprone measurements are known in the external data. Simulation results under a variety of scenarios demonstrate satisfactory finite sample performance of our proposed methods when measurement errors vary. We illustrate our methods using real ELISpot assay data generated by two HIV vaccine laboratories. PMID:22764070

  4. 3-D Printing as a Tool to Investigate the Effects of Changes in Rock Microstructures on Permeability

    NASA Astrophysics Data System (ADS)

    Head, D. A.; Vanorio, T.

    2016-12-01

    Rocks are naturally heterogeneous; two rock samples with identical bulk properties can vary widely in microstructure. Understanding the evolutionary trends of rock properties requires the ability to connect time-lapse measurements of properties at different scales: the macro- scale used in the laboratory and field analyses capturing the bulk scale changes and the micro- scale used in imaging and digital techniques capturing the changes to the pore space. However, measuring those properties at different scales is very challenging, and sometimes impossible. The advent of modern 3D printing has provided an unprecedented opportunity to link those scales by combining the strengths of digital and experimental rock physics. To determine the feasibility of this technique we characterized the resolution capabilities of two different 3D printers. To calibrate our digital models with our printed models, we created a sample with an analytically solvable permeability. This allowed us to directly compare analytic calculation, numerical simulation, and laboratory measurement of permeability of the exact same sample. Next we took a CT-scanned model of a natural carbonate pore space, then iteratively digitally manipulated, 3D printed, and measured the flow properties in the laboratory. This approach allowed us to access multiple scales digitally and experimentally, to test hypotheses about how changes in rock microstructure due to compaction and dissolution affect bulk transport properties, and to connect laboratory measurements of porosity and permeability to quantities that are traditionally impossible to measure in the laboratory such as changes in surface area and tortuosity. As 3D printing technology continues to advance, we expect this technique to contribute to our ability to characterize the properties of remote and/or delicate samples as well as to test the impact of microstructural alteration on bulk physical properties in the lab in a highly consistent, repeatable manner.

  5. DATA QUALITY OBJECTIVES FOR SELECTING WASTE SAMPLES FOR BENCH-SCALE REFORMER TREATABILITY STUDIES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    BANNING DL

    2011-02-11

    This document describes the data quality objectives to select archived samples located at the 222-S Laboratory for Bench-Scale Reforming testing. The type, quantity, and quality of the data required to select the samples for Fluid Bed Steam Reformer testing are discussed. In order to maximize the efficiency and minimize the time to treat Hanford tank waste in the Waste Treatment and Immobilization Plant, additional treatment processes may be required. One of the potential treatment processes is the fluidized bed steam reformer. A determination of the adequacy of the fluidized bed steam reformer process to treat Hanford tank waste is required.more » The initial step in determining the adequacy of the fluidized bed steam reformer process is to select archived waste samples from the 222-S Laboratory that will be used in a bench scale tests. Analyses of the selected samples will be required to confirm the samples meet the shipping requirements and for comparison to the bench scale reformer (BSR) test sample selection requirements.« less

  6. A SIMPLE METHOD FOR EVALUATING DATA FROM AN INTERLABORATORY STUDY

    EPA Science Inventory

    Large-scale laboratory-and method-performance studies involving more than about 30 laboratories may be evaluated by calculating the HORRAT ratio for each test sample (HORRAT=[experimentally found among-laboratories relative standard deviation] divided by [relative standard deviat...

  7. Chapter 1.1 Process Scale-Up of Cellulose Nanocrystal Production to 25 kg per Batch at the Forest Products Laboratory

    Treesearch

    Richard S. Reiner; Alan W. Rudie

    2013-01-01

    The Fiber and Chemical Sciences Research Work Unit at the Forest Products Laboratory began working out the preparation of cellulose nanocrystals in 2006, using the method of Dong, Revol, and Gray. Initial samples were provided to several scientists within the Forest Service. Continued requests for this material forced scale-up from the initial 20 g scale to kg...

  8. Characteristics of coking coal burnout

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nakamura, M.; Bailey, J.G.

    An attempt was made to clarify the characteristics of coking coal burnout by the morphological analysis of char and fly ash samples. Laboratory-scale combustion testing, simulating an ignition process, was carried out for three kinds of coal (two coking coals and one non-coking coal for reference), and sampled chars were analyzed for size, shape and type by image analysis. The full combustion process was examined in industrial-scale combustion testing for the same kinds of coal. Char sampled at the burner outlet and fly ash at the furnace exit were also analyzed. The difference between the char type, swelling properties, agglomeration,more » anisotropy and carbon burnout were compared at laboratory scale and at industrial scale. As a result, it was found that coking coals produced chars with relatively thicker walls, which mainly impeded char burnout, especially for low volatile coals.« less

  9. Aircraft data summaries for the SURE intensives. Final report. [Sampling done July 1978 near Duncan Falls, Ohio and Scranton, Pennsylvania

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keifer, W.S.; Blumenthal, D.L.; Tommerdahl, J.B.

    1981-09-01

    As part of the EPRI sulfate regional experiment (SURE), Meteorology Research, Inc., (MRI) and Research Triangle Institute (RTI) conducted six air quality sampling programs in the eastern United States using instrumented aircraft. This volume includes the air quality and meteorological data obtained during the July 1978 Intensive when MRI sampled near the Duncan Falls, Ohio, SURE Station and RTI sampled near the Scranton, Pennsylvania, SURE Station. During the last part of the July 1978 sampling period, both MRI and RTI aircraft participated in a large regional-scale sampling program with Brookhaven National Laboratory (BNL) and Pacific Northwest Laboratory (PNL). Only themore » data obtained by the MRI and RTI aircraft during this regional-scale sapling program are included in this volume.« less

  10. Quantifying the role that laboratory experiment sample scale has on observed material properties and mechanistic behaviors that cause well systems to fail

    NASA Astrophysics Data System (ADS)

    Huerta, N. J.; Fahrman, B.; Rod, K. A.; Fernandez, C. A.; Crandall, D.; Moore, J.

    2017-12-01

    Laboratory experiments provide a robust method to analyze well integrity. Experiments are relatively cheap, controlled, and repeatable. However, simplifying assumptions, apparatus limitations, and scaling are ubiquitous obstacles for translating results from the bench to the field. We focus on advancing the correlation between laboratory results and field conditions by characterizing how failure varies with specimen geometry using two experimental approaches. The first approach is designed to measure the shear bond strength between steel and cement in a down-scaled (< 3" diameter) well geometry. We use several cylindrical casing-cement-casing geometries that either mimic the scaling ratios found in the field or maximize the amount of metal and cement in the sample. We subject the samples to thermal shock cycles to simulate damage to the interfaces from operations. The bond was then measured via a push-out test. We found that not only did expected parameters, e.g. curing time, play a role in shear-bond strength but also that scaling of the geometry was important. The second approach is designed to observe failure of the well system due to pressure applied on the inside of a lab-scale (1.5" diameter) cylindrical casing-cement-rock geometry. The loading apparatus and sample are housed within an industrial X-ray CT scanner capable of imaging the system while under pressure. Radial tension cracks were observed in the cement after an applied internal pressure of 3000 psi and propagated through the cement and into the rock as pressure was increased. Based on our current suite of tests we find that the relationship between sample diameters and thicknesses is an important consideration when observing the strength and failure of well systems. The test results contribute to our knowledge of well system failure, evaluation and optimization of new cements, as well as the applicability of using scaled-down tests as a proxy for understanding field-scale conditions.

  11. Replicating the microbial community and water quality performance of full-scale slow sand filters in laboratory-scale filters.

    PubMed

    Haig, Sarah-Jane; Quince, Christopher; Davies, Robert L; Dorea, Caetano C; Collins, Gavin

    2014-09-15

    Previous laboratory-scale studies to characterise the functional microbial ecology of slow sand filters have suffered from methodological limitations that could compromise their relevance to full-scale systems. Therefore, to ascertain if laboratory-scale slow sand filters (L-SSFs) can replicate the microbial community and water quality production of industrially operated full-scale slow sand filters (I-SSFs), eight cylindrical L-SSFs were constructed and were used to treat water from the same source as the I-SSFs. Half of the L-SSFs sand beds were composed of sterilized sand (sterile) from the industrial filters and the other half with sand taken directly from the same industrial filter (non-sterile). All filters were operated for 10 weeks, with the microbial community and water quality parameters sampled and analysed weekly. To characterize the microbial community phyla-specific qPCR assays and 454 pyrosequencing of the 16S rRNA gene were used in conjunction with an array of statistical techniques. The results demonstrate that it is possible to mimic both the water quality production and the structure of the microbial community of full-scale filters in the laboratory - at all levels of taxonomic classification except OTU - thus allowing comparison of LSSF experiments with full-scale units. Further, it was found that the sand type composing the filter bed (non-sterile or sterile), the water quality produced, the age of the filters and the depth of sand samples were all significant factors in explaining observed differences in the structure of the microbial consortia. This study is the first to the authors' knowledge that demonstrates that scaled-down slow sand filters can accurately reproduce the water quality and microbial consortia of full-scale slow sand filters. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. A process for creating multimetric indices for large-scale aquatic surveys

    EPA Science Inventory

    Differences in sampling and laboratory protocols, differences in techniques used to evaluate metrics, and differing scales of calibration and application prohibit the use of many existing multimetric indices (MMIs) in large-scale bioassessments. We describe an approach to develop...

  13. EPOS-WP16: A Platform for European Multi-scale Laboratories

    NASA Astrophysics Data System (ADS)

    Spiers, Chris; Drury, Martyn; Kan-Parker, Mirjam; Lange, Otto; Willingshofer, Ernst; Funiciello, Francesca; Rosenau, Matthias; Scarlato, Piergiorgio; Sagnotti, Leonardo; W16 Participants

    2016-04-01

    The participant countries in EPOS embody a wide range of world-class laboratory infrastructures ranging from high temperature and pressure experimental facilities, to electron microscopy, micro-beam analysis, analogue modeling and paleomagnetic laboratories. Most data produced by the various laboratory centres and networks are presently available only in limited "final form" in publications. As such many data remain inaccessible and/or poorly preserved. However, the data produced at the participating laboratories are crucial to serving society's need for geo-resources exploration and for protection against geo-hazards. Indeed, to model resource formation and system behaviour during exploitation, we need an understanding from the molecular to the continental scale, based on experimental data. This contribution will describe the work plans that the laboratories community in Europe is making, in the context of EPOS. The main objectives are: - To collect and harmonize available and emerging laboratory data on the properties and processes controlling rock system behaviour at multiple scales, in order to generate products accessible and interoperable through services for supporting research activities. - To co-ordinate the development, integration and trans-national usage of the major solid Earth Science laboratory centres and specialist networks. The length scales encompassed by the infrastructures included range from the nano- and micrometer levels (electron microscopy and micro-beam analysis) to the scale of experiments on centimetre sized samples, and to analogue model experiments simulating the reservoir scale, the basin scale and the plate scale. - To provide products and services supporting research into Geo-resources and Geo-storage, Geo-hazards and Earth System Evolution.

  14. Analysis of the 2H-evaporator scale samples (HTF-17-56, -57)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hay, M.; Coleman, C.; Diprete, D.

    Savannah River National Laboratory analyzed scale samples from both the wall and cone sections of the 242-16H Evaporator prior to chemical cleaning. The samples were analyzed for uranium and plutonium isotopes required for a Nuclear Criticality Safety Assessment of the scale removal process. The analysis of the scale samples found the material to contain crystalline nitrated cancrinite and clarkeite. Samples from both the wall and cone contain depleted uranium. Uranium concentrations of 16.8 wt% 4.76 wt% were measured in the wall and cone samples, respectively. The ratio of plutonium isotopes in both samples is ~85% Pu-239 and ~15% Pu-238 bymore » mass and shows approximately the same 3.5 times higher concentration in the wall sample versus the cone sample as observed in the uranium concentrations. The mercury concentrations measured in the scale samples were higher than previously reported values. The wall sample contains 19.4 wt% mercury and the cone scale sample 11.4 wt% mercury. The results from the current scales samples show reasonable agreement with previous 242-16H Evaporator scale sample analysis; however, the uranium concentration in the current wall sample is substantially higher than previous measurements.« less

  15. Comparison of Different Matrices as Potential Quality Control Samples for Neurochemical Dementia Diagnostics.

    PubMed

    Lelental, Natalia; Brandner, Sebastian; Kofanova, Olga; Blennow, Kaj; Zetterberg, Henrik; Andreasson, Ulf; Engelborghs, Sebastiaan; Mroczko, Barbara; Gabryelewicz, Tomasz; Teunissen, Charlotte; Mollenhauer, Brit; Parnetti, Lucilla; Chiasserini, Davide; Molinuevo, Jose Luis; Perret-Liaudet, Armand; Verbeek, Marcel M; Andreasen, Niels; Brosseron, Frederic; Bahl, Justyna M C; Herukka, Sanna-Kaisa; Hausner, Lucrezia; Frölich, Lutz; Labonte, Anne; Poirier, Judes; Miller, Anne-Marie; Zilka, Norbert; Kovacech, Branislav; Urbani, Andrea; Suardi, Silvia; Oliveira, Catarina; Baldeiras, Ines; Dubois, Bruno; Rot, Uros; Lehmann, Sylvain; Skinningsrud, Anders; Betsou, Fay; Wiltfang, Jens; Gkatzima, Olymbia; Winblad, Bengt; Buchfelder, Michael; Kornhuber, Johannes; Lewczuk, Piotr

    2016-03-01

    Assay-vendor independent quality control (QC) samples for neurochemical dementia diagnostics (NDD) biomarkers are so far commercially unavailable. This requires that NDD laboratories prepare their own QC samples, for example by pooling leftover cerebrospinal fluid (CSF) samples. To prepare and test alternative matrices for QC samples that could facilitate intra- and inter-laboratory QC of the NDD biomarkers. Three matrices were validated in this study: (A) human pooled CSF, (B) Aβ peptides spiked into human prediluted plasma, and (C) Aβ peptides spiked into solution of bovine serum albumin in phosphate-buffered saline. All matrices were tested also after supplementation with an antibacterial agent (sodium azide). We analyzed short- and long-term stability of the biomarkers with ELISA and chemiluminescence (Fujirebio Europe, MSD, IBL International), and performed an inter-laboratory variability study. NDD biomarkers turned out to be stable in almost all samples stored at the tested conditions for up to 14 days as well as in samples stored deep-frozen (at - 80°C) for up to one year. Sodium azide did not influence biomarker stability. Inter-center variability of the samples sent at room temperature (pooled CSF, freeze-dried CSF, and four artificial matrices) was comparable to the results obtained on deep-frozen samples in other large-scale projects. Our results suggest that it is possible to replace self-made, CSF-based QC samples with large-scale volumes of QC materials prepared with artificial peptides and matrices. This would greatly facilitate intra- and inter-laboratory QC schedules for NDD measurements.

  16. Bridging the gap between sample collection and laboratory analysis: using dried blood spots to identify human exposure to chemical agents

    NASA Astrophysics Data System (ADS)

    Hamelin, Elizabeth I.; Blake, Thomas A.; Perez, Jonas W.; Crow, Brian S.; Shaner, Rebecca L.; Coleman, Rebecca M.; Johnson, Rudolph C.

    2016-05-01

    Public health response to large scale chemical emergencies presents logistical challenges for sample collection, transport, and analysis. Diagnostic methods used to identify and determine exposure to chemical warfare agents, toxins, and poisons traditionally involve blood collection by phlebotomists, cold transport of biomedical samples, and costly sample preparation techniques. Use of dried blood spots, which consist of dried blood on an FDA-approved substrate, can increase analyte stability, decrease infection hazard for those handling samples, greatly reduce the cost of shipping/storing samples by removing the need for refrigeration and cold chain transportation, and be self-prepared by potentially exposed individuals using a simple finger prick and blood spot compatible paper. Our laboratory has developed clinical assays to detect human exposures to nerve agents through the analysis of specific protein adducts and metabolites, for which a simple extraction from a dried blood spot is sufficient for removing matrix interferents and attaining sensitivities on par with traditional sampling methods. The use of dried blood spots can bridge the gap between the laboratory and the field allowing for large scale sample collection with minimal impact on hospital resources while maintaining sensitivity, specificity, traceability, and quality requirements for both clinical and forensic applications.

  17. Role of Hydrodynamic and Mineralogical Heterogeneities on Reactive Transport Processes.

    NASA Astrophysics Data System (ADS)

    Luquot, L.; Garcia-Rios, M.; soler Sagarra, J.; Gouze, P.; Martinez-Perez, L.; Carrera, J.

    2017-12-01

    Predicting reactive transport at large scale, i.e., Darcy- and field- scale, is still challenging considering the number of heterogeneities that may be present from nm- to pore-scale. It is well documented that conventional continuum-scale approaches oversimplify and/or ignore many important aspects of rock structure, chemical reactions, fluid displacement and transport, which, as a consequence, results in uncertainties when applied to field-scale operations. The changes in flow and reactive transport across the different spatial and temporal scales are of central concern in many geological applications such as groundwater systems, geo-energy, rock building heritage and geological storage... In this presentation, we will discuss some laboratory and numerical results on how local heterogeneities (structural, hydrodynamic and mineralogical) can affect the localization and the rate of the reaction processes. Different flow through laboratory experiments using various rock samples will be presented, from simple monomineral rocks such as limestone samples, and more complex rocks composed of different minerals with a large range of kinetic reactions. A new numerical approach based on multirate water mixing approach will be presented and applied to one of the laboratory experiment in order to analyze and distinguish the effect of the mineralogy distribution and the hydrodynamic heterogeneity on the total reaction rate.

  18. Measuring ignitability for in situ burning of oil spills weathered under Arctic conditions: from laboratory studies to large-scale field experiments.

    PubMed

    Fritt-Rasmussen, Janne; Brandvik, Per Johan

    2011-08-01

    This paper compares the ignitability of Troll B crude oil weathered under simulated Arctic conditions (0%, 50% and 90% ice cover). The experiments were performed in different scales at SINTEF's laboratories in Trondheim, field research station on Svalbard and in broken ice (70-90% ice cover) in the Barents Sea. Samples from the weathering experiments were tested for ignitability using the same laboratory burning cell. The measured ignitability from the experiments in these different scales showed a good agreement for samples with similar weathering. The ice conditions clearly affected the weathering process, and 70% ice or more reduces the weathering and allows a longer time window for in situ burning. The results from the Barents Sea revealed that weathering and ignitability can vary within an oil slick. This field use of the burning cell demonstrated that it can be used as an operational tool to monitor the ignitability of oil spills. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. EFFECTS OF STORAGE ON STABILITY AND PATHOGEN REDUCTION IN BIOSOLIDS

    EPA Science Inventory

    Storage can be an effective means of stabilizing small quantities of wastewater sludge. This paper summarizes the performance of two laboratory-scale sludge storage units and that of four full-scale tanks sampled at four treatment facilities in eastern Nebraska. The bench-scale u...

  20. Design of a laboratory scale fluidized bed reactor

    NASA Astrophysics Data System (ADS)

    Wikström, E.; Andersson, P.; Marklund, S.

    1998-04-01

    The aim of this project was to construct a laboratory scale fluidized bed reactor that simulates the behavior of full scale municipal solid waste combustors. The design of this reactor is thoroughly described. The size of the laboratory scale fluidized bed reactor is 5 kW, which corresponds to a fuel-feeding rate of approximately 1 kg/h. The reactor system consists of four parts: a bed section, a freeboard section, a convector (postcombustion zone), and an air pollution control (APC) device system. The inside diameter of the reactor is 100 mm at the bed section and it widens to 200 mm in diameter in the freeboard section; the total height of the reactor is 1760 mm. The convector part consists of five identical sections; each section is 2700 mm long and has an inside diameter of 44.3 mm. The reactor is flexible regarding the placement and number of sampling ports. At the beginning of the first convector unit and at the end of each unit there are sampling ports for organic micropollutants (OMP). This makes it possible to study the composition of the flue gases at various residence times. Sampling ports for inorganic compounds and particulate matter are also placed in the convector section. All operating parameters, reactor temperatures, concentrations of CO, CO2, O2, SO2, NO, and NO2 are continuously measured and stored at selected intervals for further evaluation. These unique features enable full control over the fuel feed, air flows, and air distribution as well as over the temperature profile. Elaborate details are provided regarding the configuration of the fuel-feeding systems, the fluidized bed, the convector section, and the APC device. This laboratory reactor enables detailed studies of the formation mechanisms of OMP, such as polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), poly-chlorinated biphenyls (PCBs), and polychlorinated benzenes (PCBzs). With this system formation mechanisms of OMP occurring in both the combustion and postcombustion zones can be studied. Other advantages are memory effect minimization and the reduction of experimental costs compared to full scale combustors. Comparison of the combustion parameters and emission data from this 5 kW laboratory scale reactor with full scale combustors shows good agreement regarding emission levels and PCDD/PCDF congener patterns. This indicates that the important formation and degradation reactions of OMP in the reactor are the same formation mechanisms as in full scale combustors.

  1. Field application of a planted fixed bed reactor (PFR) for support media and rhizosphere investigation using undisturbed samples from full-scale constructed wetlands.

    PubMed

    Barreto, A B; Vasconcellos, G R; von Sperling, M; Kuschk, P; Kappelmeyer, U; Vasel, J L

    2015-01-01

    This study presents a novel method for investigations on undisturbed samples from full-scale horizontal subsurface-flow constructed wetlands (HSSFCW). The planted fixed bed reactor (PFR), developed at the Helmholtz Center for Environmental Research (UFZ), is a universal test unit for planted soil filters that reproduces the operational conditions of a constructed wetland (CW) system in laboratory scale. The present research proposes modifications on the PFR original configuration in order to allow its operation in field conditions. A mobile device to obtain undisturbed samples from real-scale HSSFCW was also developed. The experimental setting is presented with two possible operational configurations. The first allows the removal and replacement of undisturbed samples in the CW bed for laboratory investigations, guaranteeing sample integrity with a mobile device. The second allows the continuous operation of the PFR and undisturbed samples as a fraction of the support media, reproducing the same environmental conditions outside the real-scale system. Investigations on the hydrodynamics of the adapted PFR were carried out with saline tracer tests, validating the proposed adaptation. Six adapted PFR units were installed next to full-scale HSSFCW beds and fed with interstitial liquid pumped from two regions of planted and unplanted support media. Fourteen points were monitored along the system, covering carbon fractions, nitrogen and sulfate. The results indicate the method as a promising tool for investigations on CW support media, rhizosphere and open space for studies on CW modeling, respirometry, kinetic parameters, microbial communities, redox potential and plant influence on HSSFCW.

  2. Institutional practices and policies in acid-base testing: a self reported Croatian survey study on behalf of the Croatian society of medical biochemistry and laboratory medicine Working Group for acid-base balance.

    PubMed

    Dukić, Lora; Simundić, Ana-Maria

    2014-01-01

    The aim of this survey study was to assess the current practices and policies in use related to the various steps in the blood gas testing process, across hospital laboratories in Croatia. First questionnaire was sent by email to all medical biochemistry laboratories (N = 104) within general, specialized and clinical hospitals and university hospital centres to identify laboratories which perform blood gas analysis. Second questionnaire with detailed questions about sample collection, analysis and quality control procedures, was sent only to 47 laboratories identified by the first survey. Questionnaire was designed as combination of questions and statements with Likert scale. Third questionnaire was sent to all participating laboratories (N=47) for additional clarification for either indeterminate or unclear answers. Blood gas analysis is performed in 47/104 hospital laboratories in Croatia. In 25/41 (0.61) of the laboratories capillary blood gas sampling is the preferred sample type for adult patient population, whereas arterial blood sample is preferentially used in only 5/44 laboratories (0.11). Blood sampling and sample processing for capillary samples is done almost always by laboratory technicians (36/41 and 37/44, respectively), whereas arterial blood sampling is almost always done by the physician (24/29) and only rarely by a nurse (5/28). Sample acceptance criteria and sample analysis are in accordance with international recommendations for majority of laboratories. 43/44 laboratories participate in the national EQA program. POCT analyzers are installed outside of the laboratory in 20/47 (0.43) institutions. Laboratory staff is responsible for education and training of ward personnel, quality control and instrument maintenance in only 12/22, 11/20 and 9/20 institutions, respectively. Practices related to collection and analysis for blood gases in Croatia are not standardised and vary substantially between laboratories. POCT analyzers are not under the direct supervision by laboratory personnel in a large proportion of surveyed institutions. Collective efforts should be made to harmonize and improve policies and procedures related to blood gas testing in Croatian laboratories.

  3. Multiscale Laboratory Infrastructure and Services to users: Plans within EPOS

    NASA Astrophysics Data System (ADS)

    Spiers, Chris; Willingshofer, Ernst; Drury, Martyn; Funiciello, Francesca; Rosenau, Matthias; Scarlato, Piergiorgio; Sagnotti, Leonardo; EPOS WG6, Corrado Cimarelli

    2015-04-01

    The participant countries in EPOS embody a wide range of world-class laboratory infrastructures ranging from high temperature and pressure experimental facilities, to electron microscopy, micro-beam analysis, analogue modeling and paleomagnetic laboratories. Most data produced by the various laboratory centres and networks are presently available only in limited "final form" in publications. Many data remain inaccessible and/or poorly preserved. However, the data produced at the participating laboratories are crucial to serving society's need for geo-resources exploration and for protection against geo-hazards. Indeed, to model resource formation and system behaviour during exploitation, we need an understanding from the molecular to the continental scale, based on experimental data. This contribution will describe the plans that the laboratories community in Europe is making, in the context of EPOS. The main objectives are: • To collect and harmonize available and emerging laboratory data on the properties and processes controlling rock system behaviour at multiple scales, in order to generate products accessible and interoperable through services for supporting research activities. • To co-ordinate the development, integration and trans-national usage of the major solid Earth Science laboratory centres and specialist networks. The length scales encompassed by the infrastructures included range from the nano- and micrometer levels (electron microscopy and micro-beam analysis) to the scale of experiments on centimetre sized samples, and to analogue model experiments simulating the reservoir scale, the basin scale and the plate scale. • To provide products and services supporting research into Geo-resources and Geo-storage, Geo-hazards and Earth System Evolution. If the EPOS Implementation Phase proposal presently under construction is successful, then a range of services and transnational activities will be put in place to realize these objectives.

  4. ENHANCED BIOREMEDIATION UTILIZING HYDROGEN PEROXIDE AS A SUPPLEMENTAL SOURCE OF OXYGEN: A LABORATORY AND FIELD STUDY

    EPA Science Inventory

    Laboratory and field scale studies were conducted to investigate the feasibility of using hydrogen peroxide as a supplemental source of oxygen for bioremediation of an aviation gasoline fuel spill. Field samples of aviation gasoline contaminated aquifer material were artificially...

  5. Atmospheric Carbon Monoxide Mixing Ratios NOAA Climate Monitoring and Diagnostics Laboratory Cooperative Air Sampling Network (1988-1993) (DB1011)

    DOE Data Explorer

    Novelli, P. C.; Masarie, K. A.

    1994-01-01

    Individual site files provide CO mixing ratios in parts per billion (ppb) (ppb = parts in 109 by mole fraction) based on measurements from the NOAA/CMDL Cooperative Air Sampling Network beginning 1988. Data are provided through June 1993 for stations at which the first sample was collected before July 1991. All samples were analyzed for CO at the NOAA/CMDL laboratory in Boulder by gas chromatography with mercuric oxide reduction detection, and all measurements are referenced to the CMDL CO scale (Novelli et al., 1991, Novelli et al., 1994).

  6. Examination of Pre-Productions Samples of UOP IONSIV(R) IE-910 and IE-911

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walker, D.D.

    2001-07-10

    This report includes results of the extensive examination of newly-prepared laboratory-scale and pre-production samples of caustic-washed CST [crystalline silicotitanate] as compared to similar performance data for commercially-available and baseline samples. Conclusions from this work include the following.

  7. Geometric factor and influence of sensors in the establishment of a resistivity-moisture relation in soil samples

    NASA Astrophysics Data System (ADS)

    López-Sánchez, M.; Mansilla-Plaza, L.; Sánchez-de-laOrden, M.

    2017-10-01

    Prior to field scale research, soil samples are analysed on a laboratory scale for electrical resistivity calibrations. Currently, there are a variety of field instruments to estimate the water content in soils using different physical phenomena. These instruments can be used to develop moisture-resistivity relationships on the same soil samples. This assures that measurements are performed on the same material and under the same conditions (e.g., humidity and temperature). A geometric factor is applied to the location of electrodes, in order to calculate the apparent electrical resistivity of the laboratory test cells. This geometric factor can be determined in three different ways: by means of the use of an analytical approximation, laboratory trials (experimental approximation), or by the analysis of a numerical model. The first case, the analytical approximation, is not appropriate for complex cells or arrays. And both, the experimental and numerical approximation can lead to inaccurate results. Therefore, we propose a novel approach to obtain a compromise solution between both techniques, providing a more precise determination of the geometrical factor.

  8. Spatiotemporal variability in biogenic gas dynamics in a subtropical peat soil at the laboratory scale is revealed using high-resolution ground-penetrating radar

    NASA Astrophysics Data System (ADS)

    Mustasaar, Mario; Comas, Xavier

    2017-09-01

    The importance of peatlands as sources of greenhouse gas emissions has been demonstrated in many studies during the last two decades. While most studies have shown the heterogeneous distribution of biogenic gas in peat soils at the field scale (sampling volumes in the order of meters), little information exists for submeter scales, particularly relevant to properly capture the dynamics of hot spots for gas accumulation and release when designing sampling routines with methods that use smaller (i.e., submeter) sampling volumes like flux chambers. In this study, ground-penetrating radar is used at the laboratory scale to evaluate biogenic gas dynamics at high spatial resolution (i.e., cm) in a peat monolith from the Everglades. The results indicate sharp changes (both spatially and temporally) in the dynamics of gas accumulation and release, representing hot spots for production and release of biogenic gases with surface areas ranging between 5 to 10 cm diameter and are associated with increases in porosity. Furthermore, changes in gas composition and inferred methane (CH4) and carbon dioxide (CO2) fluxes also displayed a high spatiotemporal variability associated with hot spots, resulting in CH4 and CO2 flux estimates showing differences up to 1 order of magnitude during the same day for different parts of the sample. This work follows on recent studies in the Everglades and questions the appropriateness of spatial and temporal scales of measurement when defining gas dynamics by showing how flux values may change both spatially and temporarily even when considering submeter spatial scales.

  9. The influence of hydrocarbons in changing the mechanical and acoustic properties of a carbonate reservoir: implications of laboratory results on larger scale processes

    NASA Astrophysics Data System (ADS)

    Trippetta, Fabio; Ruggieri, Roberta; Geremia, Davide; Brandano, Marco

    2017-04-01

    Understanding hydraulic and mechanical processes that acted in reservoir rocks and their effect on the rock properties is of a great interest for both scientific and industry fields. In this work we investigate the role of hydrocarbons in changing the petrophysical properties of rock by merging laboratory, outcrops, and subsurface data focusing on the carbonate-bearing Majella reservoir (Bolognano formation). This reservoir represents an interesting analogue for subsurface carbonate reservoirs and is made of high porosity (8 to 28%) ramp calcarenites saturated by hydrocarbon in the state of bitumen at the surface. Within this lithology clean and bitumen bearing samples were investigated. For both groups, density, porosity, P and S wave velocity, at increasing confining pressure and deformation tests were conducted on cylindrical specimens with BRAVA apparatus at the HP-HT Laboratory of the Istituto Nazionale di Geofisica e Vulcanologia (INGV) in Rome, Italy. The performed petrophysical characterization, shows a very good correlation between Vp, Vs and porosity and a pressure independent Vp/Vs ratio while the presence of bitumen within samples increases both Vp and Vs. P-wave velocity hysteresis measured at ambient pressure after 100 MPa of applied confining pressure, suggests an almost pure elastic behaviour for bitumen-bearing samples and a more inelastic behaviour for cleaner samples. Calculated dynamic Young's modulus is larger for bitumen-bearing samples and these data are confirmed by cyclic deformation tests where the same samples generally record larger strength, larger Young's modulus and smaller permanent strain respect to clean samples. Starting from laboratory data, we also derived a synthetic acoustic model highlighting an increase in acoustic impedance for bitumen-bearing samples. Models have been also performed simulating a saturation with decreasing API° hydrocarbons, showing opposite effects on the seismic properties of the reservoir respect to bitumen. In order to compare our laboratory results at larger scale we selected 11 outcrops of the same lithofacies of laboratory samples both clean and bitumen-saturated. Fractures orientations, from the scan-line method, are similar for the two types of outcrops and they follow the same trends of literature data collected on older rocks. On the other hand, spacing data show very lower fracture density for bitumen-saturated outcrops confirming laboratory observations. In conclusion, laboratory experiments highlight a more elastic behaviour for bitumen-bearing samples and saturated outcrops are less prone to fracture respect to clean outcrops. Presence of bitumen has, thus, a positive influence on mechanical properties of the reservoir while acoustic model suggests that lighter oils should have an opposite effect. Geologically, this suggests that hydrocarbons migration in the study area predates the last stage of deformation giving also clues about a relatively high density of the oil when deformation began.

  10. Multiscale pore structure and constitutive models of fine-grained rocks

    NASA Astrophysics Data System (ADS)

    Heath, J. E.; Dewers, T. A.; Shields, E. A.; Yoon, H.; Milliken, K. L.

    2017-12-01

    A foundational concept of continuum poromechanics is the representative elementary volume or REV: an amount of material large enough that pore- or grain-scale fluctuations in relevant properties are dissipated to a definable mean, but smaller than length scales of heterogeneity. We determine 2D-equivalent representative elementary areas (REAs) of pore areal fraction of three major types of mudrocks by applying multi-beam scanning electron microscopy (mSEM) to obtain terapixel image mosaics. Image analysis obtains pore areal fraction and pore size and shape as a function of progressively larger measurement areas. Using backscattering imaging and mSEM data, pores are identified by the components within which they occur, such as in organics or the clastic matrix. We correlate pore areal fraction with nano-indentation, micropillar compression, and axysimmetic testing at multiple length scales on a terrigenous-argillaceous mudrock sample. The combined data set is used to: investigate representative elementary volumes (and areas for the 2D images); determine if scale separation occurs; and determine if transport and mechanical properties at a given length scale can be statistically defined. Clear scale separation occurs between REAs and observable heterogeneity in two of the samples. A highly-laminated sample exhibits fine-scale heterogeneity and an overlapping in scales, in which case typical continuum assumptions on statistical variability may break down. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology and Engineering Solutions of Sandia LLC, a wholly owned subsidiary of Honeywell International Inc. for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525.

  11. Field Exploration and Life Detection Sampling Through Planetary Analogue Sampling (FELDSPAR).

    NASA Technical Reports Server (NTRS)

    Stockton, A.; Amador, E. S.; Cable, M. L.; Cantrell, T.; Chaudry, N.; Cullen, T.; Duca, Z.; Gentry, D. M.; Kirby, J.; Jacobsen, M.; hide

    2017-01-01

    Exploration missions to Mars rely on rovers to perform analyses over small sampling areas; however, landing sites for these missions are selected based on large-scale, low-resolution remote data. The use of Earth analogue environments to estimate the multi-scale spatial distributions of key signatures of habitability can help ensure mission science goals are met. A main goal of FELDSPAR is to conduct field operations analogous to Mars sample return in its science, operations, and technology from landing site selection, to in-field sampling location selection, remote or stand-off analysis, in situ analysis, and home laboratory analysis. Lava fields and volcanic regions are relevant analogues to Martian landscapes due to desiccation, low nutrient availability, and temperature extremes. Operationally, many Icelandic lava fields are remote enough to require that field expeditions address several sampling constraints that are experienced in robotic exploration, including in situ and sample return missions. The Fimmvruhls lava field was formed by a basaltic effusive eruption associated with the 2010 Eyjafjallajkull eruption. Mlifellssandur is a recently deglaciated plain to the north of the Myrdalsjkull glacier. Holuhraun was formed by a 2014 fissure eruptions just north of the large Vatnajkull glacier. Dyngjusandur is an alluvial plain apparently kept barren by repeated mechanical weathering. Informed by our 2013 expedition, we collected samples in nested triangular grids every decade from the 10 cm scale to the 1 km scale (as permitted by the size of the site). Satellite imagery is available for older sites, and for Mlifellssandur, Holuhraun, and Dyngjusandur we obtained overhead imagery at 1 m to 200 m elevation. PanCam-style photographs were taken in the field by sampling personnel. In-field reflectance spectroscopy was also obtained with an ASD spectrometer in Dyngjusandur. All sites chosen were 'homogeneous' in apparent color, morphology, moisture, grain size, and reflectance spectra at all scales greater than 10 cm. Field lab assays were conducted to monitor microbial habitation, including ATP quantification, qPCR for fungal, bacterial, and archaeal DNA, and direct cell imaging using fluorescence microscopy. Home laboratory analyses include Raman spectroscopy and community sequencing. ATP appeared to be significantly more sensitive to small changes in sampling location than qPCR or fluorescence microscopy. Bacterial and archaeal DNA content were more consistent at the smaller scales, but similarly variable across more distant sites. Conversely, cell counts and fungal DNA content have significant local variation but appear relatively homogeneous over scales of 1 km. ATP, bacterial DNA, and archaeal DNA content were relatively well correlated at many spatial scales. While we have observed spatial variation at various scales and are beginning to observe how that variation fluctuates over time as biodiversity recovers after an eruption, we do not yet fully understand what parameters lead to the observed spatial variation. Home laboratory analyses will help us further understand the elemental and structural composition of the basaltic matrices, but further field analyses are vital for the understanding how temperature, moisture, incident radiation, and so forth influence the habitability of a microclimate.

  12. Quantitative analysis of nano-pore geomaterials and representative sampling for digital rock physics

    NASA Astrophysics Data System (ADS)

    Yoon, H.; Dewers, T. A.

    2014-12-01

    Geomaterials containing nano-pores (e.g., shales and carbonate rocks) have become increasingly important for emerging problems such as unconventional gas and oil resources, enhanced oil recovery, and geologic storage of CO2. Accurate prediction of coupled geophysical and chemical processes at the pore scale requires realistic representation of pore structure and topology. This is especially true for chalk materials, where pore networks are small and complex, and require characterization at sub-micron scale. In this work, we apply laser scanning confocal microscopy to characterize pore structures and microlithofacies at micron- and greater scales and dual focused ion beam-scanning electron microscopy (FIB-SEM) for 3D imaging of nanometer-to-micron scale microcracks and pore distributions. With imaging techniques advanced for nano-pore characterization, a problem of scale with FIB-SEM images is how to take nanometer scale information and apply it to the thin-section or larger scale. In this work, several texture characterization techniques including graph-based spectral segmentation, support vector machine, and principal component analysis are applied for segmentation clusters represented by 1-2 FIB-SEM samples per each cluster. Geometric and topological properties are analyzed and lattice-Boltzmann method (LBM) is used to obtain permeability at several different scales. Upscaling of permeability to the Darcy scale (e.g., the thin-section scale) with image dataset will be discussed with emphasis on understanding microfracture-matrix interaction, representative volume for FIB-SEM sampling, and multiphase flow and reactive transport. Funding from the DOE Basic Energy Sciences Geosciences Program is gratefully acknowledged. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  13. Testing the Merger Paradigm: X-ray Observations of Radio-Selected Sub-Galactic-Scale Binary AGNs

    NASA Astrophysics Data System (ADS)

    Fu, Hai

    2016-09-01

    Interactions play an important role in galaxy evolution. Strong gas inflows are expected in the process of gas-rich mergers, which may fuel intense black hole accretion and star formation. Sub-galactic-scale binary/dual AGNs thus offer elegant laboratories to study the merger-driven co-evolution phase. However, previous samples of kpc-scale binaries are small and heterogeneous. We have identified a flux-limited sample of kpc-scale binary AGNs uniformly from a wide-area high-resolution radio survey conducted by the VLA. Here we propose Chandra X-ray characterization of a subset of four radio-confirmed binary AGNs at z 0.1. Our goal is to compare their X-ray properties with those of matched control samples to test the merger-driven co-evolution paradigm.

  14. CESIUM REMOVAL FROM TANKS 241-AN-103 & 241-SX-105 & 241-AZ-101/102 COMPOSITE FOR TESTING IN BENCH SCALE STEAM REFORMER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DUNCAN JB; HUBER HJ

    2011-06-08

    This report documents the preparation of three actual Hanford tank waste samples for shipment to the Savannah River National Laboratory (SRNL). Two of the samples were dissolved saltcakes from tank 241-AN-103 (hereafter AN-103) and tank 241-SX-105 (hereafter SX-105); one sample was a supernate composite from tanks 241-AZ-101 and 241-AZ-102 (hereafter AZ-101/102). The preparation of the samples was executed following the test plans LAB-PLAN-10-00006, Test Plan for the Preparation of Samples from Hanford Tanks 241-SX-105, 241-AN-103, 241-AN-107, and LAB-PLN-10-00014, Test Plan for the Preparation of a Composite Sample from Hanford Tanks 241-AZ-101 and 241-AZ-102 for Steam Reformer Testing at the Savannahmore » River National Laboratory. All procedural steps were recorded in laboratory notebook HNF-N-274 3. Sample breakdown diagrams for AN-103 and SX-105 are presented in Appendix A. The tank samples were prepared in support of a series of treatability studies of the Fluidized Bed Steam Reforming (FBSR) process using a Bench-Scale Reformer (BSR) at SRNL. Tests with simulants have shown that the FBSR mineralized waste form is comparable to low-activity waste glass with respect to environmental durability (WSRC-STI-2008-00268, Mineralization of Radioactive Wastes by Fluidized Bed Steam Reforming (FBSR): Comparisons to Vitreous Waste Forms and Pertinent Durability Testing). However, a rigorous assessment requires long-term performance data from FB SR product formed from actual Hanford tank waste. Washington River Protection Solutions, LLC (WRPS) has initiated a Waste Form Qualification Program (WP-S.2.1-20 1 0-00 1, Fluidized Bed Steam Reformer Low-level Waste Form Qualification) to gather the data required to demonstrate that an adequate FBSR mineralized waste form can be produced. The documentation of the selection process of the three tank samples has been separately reported in RPP-48824, 'Sample Selection Process for Bench-Scale Steam Reforming Treatability Studies Using Hanford Waste Samples.'« less

  15. CESIUM REMOVAL FROM TANKS 241-AN-103 & 241-SX-105 & 241-AZ-101 & 241AZ-102 COMPOSITE FOR TESTING IN BENCH SCALE STEAM REFORMER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DUNCAN JB; HUBER HJ

    2011-04-21

    This report documents the preparation of three actual Hanford tank waste samples for shipment to the Savannah River National Laboratory (SRNL). Two of the samples were dissolved saltcakes from tank 241-AN-103 (hereafter AN-103) and tank 241-SX-105 (hereafter SX-105); one sample was a supernate composite from tanks 241-AZ-101 and 241-AZ-102 (hereafter AZ-101/102). The preparation of the samples was executed following the test plans LAB-PLAN-10-00006, Test Plan for the Preparation of Samples from Hanford Tanks 241-SX-105, 241-AN-103, 241-AN-107, and LAB-PLN-l0-00014, Test Plan for the Preparation of a Composite Sample from Hanford Tanks 241-AZ-101 and 241-AZ-102 for Steam Reformer Testing at the Savannahmore » River National Laboratory. All procedural steps were recorded in laboratory notebook HNF-N-274 3. Sample breakdown diagrams for AN-103 and SX-105 are presented in Appendix A. The tank samples were prepared in support of a series of treatability studies of the Fluidized Bed Steam Reforming (FBSR) process using a Bench-Scale Reformer (BSR) at SRNL. Tests with simulants have shown that the FBSR mineralized waste form is comparable to low-activity waste glass with respect to environmental durability (WSRC-STI-2008-00268, Mineralization of Radioactive Wastes by Fluidized Bed Steam Reforming (FBSR): Comparisons to Vitreous Waste Forms and Pertinent Durability Testing). However, a rigorous assessment requires long-term performance data from FBSR product formed from actual Hanford tank waste. Washington River Protection Solutions, LLC (WRPS) has initiated a Waste Form Qualification Program (WP-5.2.1-2010-001, Fluidized Bed Steam Reformer Low-level Waste Form Qualification) to gather the data required to demonstrate that an adequate FBSR mineralized waste form can be produced. The documentation of the selection process of the three tank samples has been separately reported in RPP-48824, Sample Selection Process for Bench-Scale Steam Reforming Treatability Studies Using Hanford Waste Samples.« less

  16. Advanced core-analyses for subsurface characterization

    NASA Astrophysics Data System (ADS)

    Pini, R.

    2017-12-01

    The heterogeneity of geological formations varies over a wide range of length scales and represents a major challenge for predicting the movement of fluids in the subsurface. Although they are inherently limited in the accessible length-scale, laboratory measurements on reservoir core samples still represent the only way to make direct observations on key transport properties. Yet, properties derived on these samples are of limited use and should be regarded as sample-specific (or `pseudos'), if the presence of sub-core scale heterogeneities is not accounted for in data processing and interpretation. The advent of imaging technology has significantly reshaped the landscape of so-called Special Core Analysis (SCAL) by providing unprecedented insight on rock structure and processes down to the scale of a single pore throat (i.e. the scale at which all reservoir processes operate). Accordingly, improved laboratory workflows are needed that make use of such wealth of information by e.g., referring to the internal structure of the sample and in-situ observations, to obtain accurate parameterisation of both rock- and flow-properties that can be used to populate numerical models. We report here on the development of such workflow for the study of solute mixing and dispersion during single- and multi-phase flows in heterogeneous porous systems through a unique combination of two complementary imaging techniques, namely X-ray Computed Tomography (CT) and Positron Emission Tomography (PET). The experimental protocol is applied to both synthetic and natural porous media, and it integrates (i) macroscopic observations (tracer effluent curves), (ii) sub-core scale parameterisation of rock heterogeneities (e.g., porosity, permeability and capillary pressure), and direct 3D observation of (iii) fluid saturation distribution and (iv) the dynamic spreading of the solute plumes. Suitable mathematical models are applied to reproduce experimental observations, including both 1D and 3D numerical schemes populated with the parameterisation above. While it validates the core-flooding experiments themselves, the calibrated mathematical model represents a key element for extending them to conditions prevalent in the subsurface, which would be otherwise not attainable in the laboratory.

  17. GHSI EMERGENCY RADIONUCLIDE BIOASSAY LABORATORY NETWORK: SUMMARY OF A RECENT EXERCISE.

    PubMed

    Li, Chunsheng; Ansari, Armin; Bartizel, Christine; Battisti, Paolo; Franck, Didier; Gerstmann, Udo; Giardina, Isabella; Guichet, Claude; Hammond, Derek; Hartmann, Martina; Jones, Robert L; Kim, Eunjoo; Ko, Raymond; Morhard, Ryan; Quayle, Deborah; Sadi, Baki; Saunders, David; Paquet, Francois

    2016-11-01

    The Global Health Security Initiative (GHSI) established a laboratory network within the GHSI community to develop their collective surge capacity for radionuclide bioassay in response to a radiological or nuclear emergency. A recent exercise was conducted to test the participating laboratories for their capabilities in screening and in vitro assay of biological samples, performing internal dose assessment and providing advice on medical intervention, if necessary, using a urine sample spiked with a single radionuclide, 241 Am. The laboratories were required to submit their reports according to the exercise schedule and using pre-formatted templates. Generally, the participating laboratories were found to be capable with respect to rapidly screening samples for radionuclide contamination, measuring the radionuclide in the samples, assessing the intake and radiation dose, and providing advice on medical intervention. However, gaps in bioassay measurement and dose assessment have been identified. The network may take steps to ensure that procedures and practices within this network be harmonised and a follow-up exercise be organised on a larger scale, with potential participation of laboratories from the networks coordinated by the International Atomic Energy Agency and the World Health Organization. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Learning Environment, Attitudes and Achievement among Middle-School Science Students Using Inquiry-Based Laboratory Activities

    ERIC Educational Resources Information Center

    Wolf, Stephen J.; Fraser, Barry J.

    2008-01-01

    This study compared inquiry and non-inquiry laboratory teaching in terms of students' perceptions of the classroom learning environment, attitudes toward science, and achievement among middle-school physical science students. Learning environment and attitude scales were found to be valid and related to each other for a sample of 1,434 students in…

  19. A manual for a laboratory information management system (LIMS) for light stable isotopes

    USGS Publications Warehouse

    Coplen, Tyler B.

    1997-01-01

    The reliability and accuracy of isotopic data can be improved by utilizing database software to (i) store information about samples, (ii) store the results of mass spectrometric isotope-ratio analyses of samples, (iii) calculate analytical results using standardized algorithms stored in a database, (iv) normalize stable isotopic data to international scales using isotopic reference materials, and (v) generate multi-sheet paper templates for convenient sample loading of automated mass-spectrometer sample preparation manifolds. Such a database program is presented herein. Major benefits of this system include (i) an increase in laboratory efficiency, (ii) reduction in the use of paper, (iii) reduction in workload due to the elimination or reduction of retyping of data by laboratory personnel, and (iv) decreased errors in data reported to sample submitters. Such a database provides a complete record of when and how often laboratory reference materials have been analyzed and provides a record of what correction factors have been used through time. It provides an audit trail for stable isotope laboratories. Since the original publication of the manual for LIMS for Light Stable Isotopes, the isotopes 3 H, 3 He, and 14 C, and the chlorofluorocarbons (CFCs), CFC-11, CFC-12, and CFC-113, have been added to this program.

  20. A manual for a Laboratory Information Management System (LIMS) for light stable isotopes

    USGS Publications Warehouse

    Coplen, Tyler B.

    1998-01-01

    The reliability and accuracy of isotopic data can be improved by utilizing database software to (i) store information about samples, (ii) store the results of mass spectrometric isotope-ratio analyses of samples, (iii) calculate analytical results using standardized algorithms stored in a database, (iv) normalize stable isotopic data to international scales using isotopic reference materials, and (v) generate multi-sheet paper templates for convenient sample loading of automated mass-spectrometer sample preparation manifolds. Such a database program is presented herein. Major benefits of this system include (i) an increase in laboratory efficiency, (ii) reduction in the use of paper, (iii) reduction in workload due to the elimination or reduction of retyping of data by laboratory personnel, and (iv) decreased errors in data reported to sample submitters. Such a database provides a complete record of when and how often laboratory reference materials have been analyzed and provides a record of what correction factors have been used through time. It provides an audit trail for stable isotope laboratories. Since the original publication of the manual for LIMS for Light Stable Isotopes, the isotopes 3 H, 3 He, and 14 C, and the chlorofluorocarbons (CFCs), CFC-11, CFC-12, and CFC-113, have been added to this program.

  1. On the use of a laser ablation as a laboratory seismic source

    NASA Astrophysics Data System (ADS)

    Shen, Chengyi; Brito, Daniel; Diaz, Julien; Zhang, Deyuan; Poydenot, Valier; Bordes, Clarisse; Garambois, Stéphane

    2017-04-01

    Mimic near-surface seismic imaging conducted in well-controlled laboratory conditions is potentially a powerful tool to study large scale wave propagations in geological media by means of upscaling. Laboratory measurements are indeed particularly suited for tests of theoretical modellings and comparisons with numerical approaches. We have developed an automated Laser Doppler Vibrometer (LDV) platform, which is able to detect and register broadband nano-scale displacements on the surface of various materials. This laboratory equipment has already been validated in experiments where piezoelectric transducers were used as seismic sources. We are currently exploring a new seismic source in our experiments, a laser ablation, in order to compensate some drawbacks encountered with piezoelectric sources. The laser ablation source is considered to be an interesting ultrasound wave generator since the 1960s. It was believed to have numerous potential applications such as the Non-Destructive Testing (NDT) and the measurements of velocities and attenuations in solid samples. We aim at adapting and developing this technique into geophysical experimental investigations in order to produce and explore complete micro-seismic data sets in the laboratory. We will first present the laser characteristics including its mechanism, stability, reproducibility, and will evaluate in particular the directivity patterns of such a seismic source. We have started by applying the laser ablation source on the surfaces of multi-scale homogeneous aluminum samples and are now testing it on heterogeneous and fractured limestone cores. Some other results of data processing will also be shown, especially the 2D-slice V P and V S tomographic images obtained in limestone samples. Apart from the experimental records, numerical simulations will be carried out for both the laser source modelling and the wave propagation in different media. First attempts will be done to compare quantitatively the experimental data with simulations. Meanwhile, CT-scan X-ray images of these limestone cores will be used to check the relative pertinences of velocity tomography images produced by this newly developed laser ablation seismic source.

  2. Ensuring the reliability of stable isotope ratio data--beyond the principle of identical treatment.

    PubMed

    Carter, J F; Fry, B

    2013-03-01

    The need for inter-laboratory comparability is crucial to facilitate the globalisation of scientific networks and the development of international databases to support scientific and criminal investigations. This article considers what lessons can be learned from a series of inter-laboratory comparison exercises organised by the Forensic Isotope Ratio Mass Spectrometry (FIRMS) network in terms of reference materials (RMs), the management of data quality, and technical limitations. The results showed that within-laboratory precision (repeatability) was generally good but between-laboratory accuracy (reproducibility) called for improvements. This review considers how stable isotope laboratories can establish a system of quality control (QC) and quality assurance (QA), emphasising issues of repeatability and reproducibility. For results to be comparable between laboratories, measurements must be traceable to the international δ-scales and, because isotope ratio measurements are reported relative to standards, a key aspect is the correct selection, calibration, and use of international and in-house RMs. The authors identify four principles which promote good laboratory practice. The principle of identical treatment by which samples and RMs are processed in an identical manner and which incorporates three further principles; the principle of identical correction (by which necessary corrections are identified and evenly applied), the principle of identical scaling (by which data are shifted and stretched to the international δ-scales), and the principle of error detection by which QC and QA results are monitored and acted upon. To achieve both good repeatability and good reproducibility it is essential to obtain RMs with internationally agreed δ-values. These RMs will act as the basis for QC and can be used to calibrate further in-house QC RMs tailored to the activities of specific laboratories. In-house QA standards must also be developed to ensure that QC-based calibrations and corrections lead to accurate results for samples. The δ-values assigned to RMs must be recorded and reported with all data. Reference materials must be used to determine what corrections are necessary for measured data. Each analytical sequence of samples must include both QC and QA materials which are subject to identical treatment during measurement and data processing. Results for these materials must be plotted, monitored, and acted upon. Periodically international RMs should be analysed as an in-house proficiency test to demonstrate results are accurate.

  3. 46 CFR 160.176-15 - Production tests and inspections.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... known weight and winch, (B) a scale, winch, and fixed anchor, or (C) a tensile test machine that is... laboratory inspector tests and inspects the lot; (ii) Perform required testing of each incoming lot of... produced the components used in the lifejacket. (d) Samples. (1) Samples used in testing and inspections...

  4. EPOS-WP16: A coherent and collaborative network of Solid Earth Multi-scale laboratories

    NASA Astrophysics Data System (ADS)

    Calignano, Elisa; Rosenau, Matthias; Lange, Otto; Spiers, Chris; Willingshofer, Ernst; Drury, Martyn; van Kan-Parker, Mirjam; Elger, Kirsten; Ulbricht, Damian; Funiciello, Francesca; Trippanera, Daniele; Sagnotti, Leonardo; Scarlato, Piergiorgio; Tesei, Telemaco; Winkler, Aldo

    2017-04-01

    Laboratory facilities are an integral part of Earth Science research. The diversity of methods employed in such infrastructures reflects the multi-scale nature of the Earth system and is essential for the understanding of its evolution, for the assessment of geo-hazards and for the sustainable exploitation of geo-resources. In the frame of EPOS (European Plate Observing System), the Working Package 16 represents a developing community of European Geoscience Multi-scale laboratories. The participant and collaborating institutions (Utrecht University, GFZ, RomaTre University, INGV, NERC, CSIC-ICTJA, CNRS, LMU, C4G-UBI, ETH, CNR*) embody several types of laboratory infrastructures, engaged in different fields of interest of Earth Science: from high temperature and pressure experimental facilities, to electron microscopy, micro-beam analysis, analogue tectonic and geodynamic modelling and paleomagnetic laboratories. The length scales encompassed by these infrastructures range from the nano- and micrometre levels (electron microscopy and micro-beam analysis) to the scale of experiments on centimetres-sized samples, and to analogue model experiments simulating the reservoir scale, the basin scale and the plate scale. The aim of WP16 is to provide two services by the year 2019: first, providing virtual access to data from laboratories (data service) and, second, providing physical access to laboratories (transnational access, TNA). Regarding the development of a data service, the current status is such that most data produced by the various laboratory centres and networks are available only in limited "final form" in publications, many data remain inaccessible and/or poorly preserved. Within EPOS the TCS Multi-scale laboratories is collecting and harmonizing available and emerging laboratory data on the properties and process controlling rock system behaviour at all relevant scales, in order to generate products accessible and interoperable through services for supporting research activities into Geo-resources and Geo-storage, Geo-hazards and Earth System Evolution. Regarding the provision of physical access to laboratories the current situation is such that access to WP16's laboratories is often based on professional relations, available budgets, shared interests and other constraints. In WP16 we aim at reducing the present diversity and non-transparency of access rules and replace ad-hoc procedures for access by a streamlined mechanisms, objective rules and a transparent policy. We work on procedures and mechanisms regulating application, negotiation, evaluation, feedback, selection, admission, approval, feasibility check, setting-up, use, monitoring and dismantling. In the end laboratories should each have a single point providing clear and transparent information on the facility itself, its services, access policy, data management policy and the legal terms and conditions for use of equipment. Through its role as an intermediary and information broker, EPOS will acquire a wealth of information from Research Infrastructures and users on the establishment of efficient collaboration agreements.

  5. Calibration of BCR-ABL1 mRNA quantification methods using genetic reference materials is a valid strategy to report results on the international scale.

    PubMed

    Mauté, Carole; Nibourel, Olivier; Réa, Delphine; Coiteux, Valérie; Grardel, Nathalie; Preudhomme, Claude; Cayuela, Jean-Michel

    2014-09-01

    Until recently, diagnostic laboratories that wanted to report on the international scale had limited options: they had to align their BCR-ABL1 quantification methods through a sample exchange with a reference laboratory to derive a conversion factor. However, commercial methods calibrated on the World Health Organization genetic reference panel are now available. We report results from a study designed to assess the comparability of the two alignment strategies. Sixty follow-up samples from chronic myeloid leukemia patients were included. Two commercial methods calibrated on the genetic reference panel were compared to two conversion factor methods routinely used at Saint-Louis Hospital, Paris, and at Lille University Hospital. Results were matched against concordance criteria (i.e., obtaining at least two of the three following landmarks: 50, 75 and 90% of the patient samples within a 2-fold, 3-fold and 5-fold range, respectively). Out of the 60 samples, more than 32 were available for comparison. Compared to the conversion factor method, the two commercial methods were within a 2-fold, 3-fold and 5-fold range for 53 and 59%, 89 and 88%, 100 and 97%, respectively of the samples analyzed at Saint-Louis. At Lille, results were 45 and 85%, 76 and 97%, 100 and 100%, respectively. Agreements between methods were observed in the four comparisons performed. Our data show that the two commercial methods selected are concordant with the conversion factor methods. This study brings the proof of principle that alignment on the international scale using the genetic reference panel is compatible with the patient sample exchange procedure. We believe that these results are particularly important for diagnostic laboratories wishing to adopt commercial methods. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  6. Combined target factor analysis and Bayesian soft-classification of interference-contaminated samples: forensic fire debris analysis.

    PubMed

    Williams, Mary R; Sigman, Michael E; Lewis, Jennifer; Pitan, Kelly McHugh

    2012-10-10

    A bayesian soft classification method combined with target factor analysis (TFA) is described and tested for the analysis of fire debris data. The method relies on analysis of the average mass spectrum across the chromatographic profile (i.e., the total ion spectrum, TIS) from multiple samples taken from a single fire scene. A library of TIS from reference ignitable liquids with assigned ASTM classification is used as the target factors in TFA. The class-conditional distributions of correlations between the target and predicted factors for each ASTM class are represented by kernel functions and analyzed by bayesian decision theory. The soft classification approach assists in assessing the probability that ignitable liquid residue from a specific ASTM E1618 class, is present in a set of samples from a single fire scene, even in the presence of unspecified background contributions from pyrolysis products. The method is demonstrated with sample data sets and then tested on laboratory-scale burn data and large-scale field test burns. The overall performance achieved in laboratory and field test of the method is approximately 80% correct classification of fire debris samples. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  7. Technical Proposal for Loading 3000 Gallon Crude Oil Samples from Field Terminal to Sandia Pressurized Tanker to Support US DOE/DOT Crude Oil Characterization Research Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lord, David L.; Allen, Raymond

    Sandia National Laboratories is seeking access to crude oil samples for a research project evaluating crude oil combustion properties in large-scale tests at Sandia National Laboratories in Albuquerque, NM. Samples must be collected from a source location and transported to Albuquerque in a tanker that complies with all applicable regulations for transportation of crude oil over public roadways. Moreover, the samples must not gain or lose any components, to include dissolved gases, from the point of loading through the time of combustion at the Sandia testing facility. In order to achieve this, Sandia designed and is currently procuring a custommore » tanker that utilizes water displacement in order to achieve these performance requirements. The water displacement procedure is modeled after the GPA 2174 standard “Obtaining Liquid Hydrocarbons Samples for Analysis by Gas Chromatography” (GPA 2014) that is used routinely by crude oil analytical laboratories for capturing and testing condensates and “live” crude oils, though it is practiced at the liter scale in most applications. The Sandia testing requires 3,000 gallons of crude. As such, the water displacement method will be upscaled and implemented in a custom tanker. This report describes the loading process for acquiring a ~3,000 gallon crude oil sample from commercial process piping containing single phase liquid crude oil at nominally 50-100 psig. This document contains a general description of the process (Section 2), detailed loading procedure (Section 3) and associated oil testing protocols (Section 4).« less

  8. Analytical performance of a versatile laboratory microscopic X-ray fluorescence system for metal uptake studies on argillaceous rocks

    NASA Astrophysics Data System (ADS)

    Gergely, Felicián; Osán, János; Szabó, B. Katalin; Török, Szabina

    2016-02-01

    Laboratory-scale microscopic X-ray fluorescence (micro-XRF) plays an increasingly important role in various fields where multielemental investigations of samples are indispensable. In case of geological samples, the reasonable detection limits (LOD) and spatial resolutions are necessary to identify the trace element content in microcrystalline level. The present study focuses on the analytical performance of a versatile laboratory-scale micro-XRF system with various options of X-ray sources and detectors to find the optimal experimental configuration in terms of sensitivities and LOD for selected elements in loaded petrographic thin sections. The method was tested for sorption studies involving thin sections prepared from cores of Boda Claystone Formation, which is a potential site for a high-level radioactive waste repository. Loaded ions in the sorption measurements were Cs(I) and Ni(II) chemically representing fission and corrosion products. Based on the collected elemental maps, the correlation between the elements representative of main rock components and the selected loaded ion was studied. For the elements of interest, Cs(I) and Ni(II) low-power iMOXS source with polycapillary and silicon drift detector was found to be the best configuration to reach the optimal LOD values. Laboratory micro-XRF was excellent to identify the responsible key minerals for the uptake of Cs(I). In case of nickel, careful corrections were needed because of the relatively high Ca content of the rock samples. The results were compared to synchrotron radiation micro-XRF.

  9. Oceanic crustal velocities from laboratory and logging measurements of Integrated Ocean Drilling Program Hole 1256D

    NASA Astrophysics Data System (ADS)

    Gilbert, Lisa A.; Salisbury, Matthew H.

    2011-09-01

    Drilling and logging of Integrated Ocean Drilling Program (IODP) Hole 1256D have provided a unique opportunity for systematically studying a fundamental problem in marine geophysics: What influences the seismic structure of oceanic crust, porosity or composition? Compressional wave velocities (Vp) logged in open hole or from regional refraction measurements integrate both the host rock and cracks in the crust. To determine the influence of cracks on Vp at several scales, we first need an accurate ground truth in the form of laboratory Vp on crack-free, or nearly crack-free samples. We measured Vp on 46 water-saturated samples at in situ pressures to determine the baseline velocities of the host rock. These new results match or exceed Vp logs throughout most of the hole, especially in the lower dikes and gabbros, where porosities are low. In contrast, samples measured at sea under ambient laboratory conditions, had consistently lower Vp than the Vp logs, even after correction to in situ pressures. Crack-free Vp calculated from simple models of logging and laboratory porosity data for different lithologies and facies suggest that crustal velocities in the lavas and upper dikes are controlled by porosity. In particular, the models demonstrate significant large-scale porosity in the lavas, especially in the sections identified as fractured flows and breccias. However, crustal velocities in the lower dikes and gabbros are increasingly controlled by petrology as the layer 2-3 boundary is approached.

  10. Dissociation in the laboratory: a comparison of strategies.

    PubMed

    Leonard, K N; Telch, M J; Harrington, P J

    1999-01-01

    Several methods for inducing dissociation in the laboratory were examined in a sample of 78 undergraduate students. Participants scoring high or low on the Dissociative Experiences Scale participated in three dissociation challenge conditions: (a) dot-staring task, (b) administration of pulsed photic and audio stimulation and (c) stimulus deprivation. Participants recorded their dissociative experiences both before and after each of the three challenge conditions. Across conditions, high DES participants reported significantly more dissociative sensations than low DES participants, even after controlling for pre-challenge dissociation. Moreover, regardless of DES status, pulsed photo and audio stimulation produced the greatest level of dissociative symptoms. The findings suggest that the induction of dissociative symptoms in a nonclinical sample is easily accomplished in the laboratory and that those who report more dissociative symptoms in their day-to-day life exhibit more pronounced dissociative symptoms when undergoing dissociative challenge in the laboratory. Implications for the study and treatment of dissociative symptoms are discussed.

  11. Hanford analytical sample projections FY 1998--FY 2002

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joyce, S.M.

    1998-02-12

    Analytical Services projections are compiled for the Hanford site based on inputs from the major programs for the years 1998 through 2002. Projections are categorized by radiation level, protocol, sample matrix and program. Analyses requirements are also presented. This document summarizes the Hanford sample projections for fiscal years 1998 to 2002. Sample projections are based on inputs submitted to Analytical Services covering Environmental Restoration, Tank Waste Remediation Systems (TWRS), Solid Waste, Liquid Effluents, Spent Nuclear Fuels, Transition Projects, Site Monitoring, Industrial Hygiene, Analytical Services and miscellaneous Hanford support activities. In addition, details on laboratory scale technology (development) work, Sample Management,more » and Data Management activities are included. This information will be used by Hanford Analytical Services (HAS) and the Sample Management Working Group (SMWG) to assure that laboratories and resources are available and effectively utilized to meet these documented needs.« less

  12. Multi-scale image segmentation and numerical modeling in carbonate rocks

    NASA Astrophysics Data System (ADS)

    Alves, G. C.; Vanorio, T.

    2016-12-01

    Numerical methods based on computational simulations can be an important tool in estimating physical properties of rocks. These can complement experimental results, especially when time constraints and sample availability are a problem. However, computational models created at different scales can yield conflicting results with respect to the physical laboratory. This problem is exacerbated in carbonate rocks due to their heterogeneity at all scales. We developed a multi-scale approach performing segmentation of the rock images and numerical modeling across several scales, accounting for those heterogeneities. As a first step, we measured the porosity and the elastic properties of a group of carbonate samples with varying micrite content. Then, samples were imaged by Scanning Electron Microscope (SEM) as well as optical microscope at different magnifications. We applied three different image segmentation techniques to create numerical models from the SEM images and performed numerical simulations of the elastic wave-equation. Our results show that a multi-scale approach can efficiently account for micro-porosities in tight micrite-supported samples, yielding acoustic velocities comparable to those obtained experimentally. Nevertheless, in high-porosity samples characterized by larger grain/micrite ratio, results show that SEM scale images tend to overestimate velocities, mostly due to their inability to capture macro- and/or intragranular- porosity. This suggests that, for high-porosity carbonate samples, optical microscope images would be more suited for numerical simulations.

  13. Automating multistep flow synthesis: approach and challenges in integrating chemistry, machines and logic

    PubMed Central

    Shukla, Chinmay A

    2017-01-01

    The implementation of automation in the multistep flow synthesis is essential for transforming laboratory-scale chemistry into a reliable industrial process. In this review, we briefly introduce the role of automation based on its application in synthesis viz. auto sampling and inline monitoring, optimization and process control. Subsequently, we have critically reviewed a few multistep flow synthesis and suggested a possible control strategy to be implemented so that it helps to reliably transfer the laboratory-scale synthesis strategy to a pilot scale at its optimum conditions. Due to the vast literature in multistep synthesis, we have classified the literature and have identified the case studies based on few criteria viz. type of reaction, heating methods, processes involving in-line separation units, telescopic synthesis, processes involving in-line quenching and process with the smallest time scale of operation. This classification will cover the broader range in the multistep synthesis literature. PMID:28684977

  14. Simulating Extraterrestrial Ices in the Laboratory

    NASA Astrophysics Data System (ADS)

    Berisford, D. F.; Carey, E. M.; Hand, K. P.; Choukroun, M.

    2017-12-01

    Several ongoing experiments at JPL attempt to simulate the ice environment for various regimes associated with icy moons. The Europa Penitent Ice Experiment (EPIX) simulates the surface environment of an icy moon, to investigate the physics of ice surface morphology growth. This experiment features half-meter-scale cryogenic ice samples, cryogenic radiative sink environment, vacuum conditions, and diurnal cycling solar simulation. The experiment also includes several smaller fixed-geometry vacuum chambers for ice simulation at Earth-like and intermediate temperature and vacuum conditions for development of surface morphology growth scaling relations. Additionally, an ice cutting facility built on a similar platform provides qualitative data on the mechanical behavior of cryogenic ice with impurities under vacuum, and allows testing of ice cutting/sampling tools relevant for landing spacecraft. A larger cutting facility is under construction at JPL, which will provide more quantitative data and allow full-scale sampling tool tests. Another facility, the JPL Ice Physics Laboratory, features icy analog simulant preparation abilities that range icy solar system objects such as Mars, Ceres and the icy satellites of Saturn and Jupiter. In addition, the Ice Physics Lab has unique facilities for Icy Analog Tidal Simulation and Rheological Studies of Cryogenic Icy Slurries, as well as equipment to perform thermal and mechanical properties testing on icy analog materials and their response to sinusoidal tidal stresses.

  15. Scaling ice microstructures from the laboratory to nature: cryo-EBSD on large samples.

    NASA Astrophysics Data System (ADS)

    Prior, David; Craw, Lisa; Kim, Daeyeong; Peyroux, Damian; Qi, Chao; Seidemann, Meike; Tooley, Lauren; Vaughan, Matthew; Wongpan, Pat

    2017-04-01

    Electron backscatter diffraction (EBSD) has extended significantly our ability to conduct detailed quantitative microstructural investigations of rocks, metals and ceramics. EBSD on ice was first developed in 2004. Techniques have improved significantly in the last decade and EBSD is now becoming more common in the microstructural analysis of ice. This is particularly true for laboratory-deformed ice where, in some cases, the fine grain sizes exclude the possibility of using a thin section of the ice. Having the orientations of all axes (rather than just the c-axis as in an optical method) yields important new information about ice microstructure. It is important to examine natural ice samples in the same way so that we can scale laboratory observations to nature. In the case of ice deformation, higher strain rates are used in the laboratory than those seen in nature. These are achieved by increasing stress and/or temperature and it is important to assess that the microstructures produced in the laboratory are comparable with those observed in nature. Natural ice samples are coarse grained. Glacier and ice sheet ice has a grain size from a few mm up to several cm. Sea and lake ice has grain sizes of a few cm to many metres. Thus extending EBSD analysis to larger sample sizes to include representative microstructures is needed. The chief impediments to working on large ice samples are sample exchange, limitations on stage motion and temperature control. Large ice samples cannot be transferred through a typical commercial cryo-transfer system that limits sample sizes. We transfer through a nitrogen glove box that encloses the main scanning electron microscope (SEM) door. The nitrogen atmosphere prevents the cold stage and the sample from becoming covered in frost. Having a long optimal working distance for EBSD (around 30mm for the Otago cryo-EBSD facility) , by moving the camera away from the pole piece, enables the stage to move without crashing into either the EBSD camera or the SEM pole piece (final lens). In theory a sample up to 100mm perpendicular to the tilt axis by 150mm parallel to the tilt axis can be analysed. In practice, the motion of our stage is restricted to maximum dimensions of 100 by 50mm by a conductive copper braid on our cold stage. Temperature control becomes harder as the samples become larger. If the samples become too warm then they will start to sublime and the quality of EBSD data will reduce. Large samples need to be relatively thin ( 5mm or less) so that conduction of heat to the cold stage is more effective at keeping the surface temperature low. In the Otago facility samples of up to 40mm by 40mm present little problem and can be analysed for several hours without significant sublimation. Larger samples need more care, e.g. fast sample transfer to keep the sample very cold. The largest samples we work on routinely are 40 by 60mm in size. We will show examples of EBSD data from glacial ice and sea ice from Antarctica and from large laboratory ice samples.

  16. The Evaluation of Carpet Steam/Heat Cleaners as Biological Sampling Device

    DTIC Science & Technology

    2011-12-08

    Vacuum Cleaner Evaluation as sampling Device Test Plan DHS Page 16 of 16 Fumigants , and Issues Related to Laboratory-scale Studies. Appl. Environ...ECBC Wet/dry Vacuum Cleaner Evaluation as sampling Device Test Plan DHS Page 1 of 16 Test Plan for The Evaluation of Carpet Steam...b. ABSTRACT unclassified c. THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 ECBC Wet/dry Vacuum Cleaner

  17. Indomethacin nanocrystals prepared by different laboratory scale methods: effect on crystalline form and dissolution behavior

    NASA Astrophysics Data System (ADS)

    Martena, Valentina; Censi, Roberta; Hoti, Ela; Malaj, Ledjan; Di Martino, Piera

    2012-12-01

    The objective of this study is to select very simple and well-known laboratory scale methods able to reduce particle size of indomethacin until the nanometric scale. The effect on the crystalline form and the dissolution behavior of the different samples was deliberately evaluated in absence of any surfactants as stabilizers. Nanocrystals of indomethacin (native crystals are in the γ form) (IDM) were obtained by three laboratory scale methods: A (Batch A: crystallization by solvent evaporation in a nano-spray dryer), B (Batch B-15 and B-30: wet milling and lyophilization), and C (Batch C-20-N and C-40-N: Cryo-milling in the presence of liquid nitrogen). Nanocrystals obtained by the method A (Batch A) crystallized into a mixture of α and γ polymorphic forms. IDM obtained by the two other methods remained in the γ form and a different attitude to the crystallinity decrease were observed, with a more considerable decrease in crystalline degree for IDM milled for 40 min in the presence of liquid nitrogen. The intrinsic dissolution rate (IDR) revealed a higher dissolution rate for Batches A and C-40-N, due to the higher IDR of α form than γ form for the Batch A, and the lower crystallinity degree for both the Batches A and C-40-N. These factors, as well as the decrease in particle size, influenced the IDM dissolution rate from the particle samples. Modifications in the solid physical state that may occur using different particle size reduction treatments have to be taken into consideration during the scale up and industrial development of new solid dosage forms.

  18. Scale problems in assessment of hydrogeological parameters of groundwater flow models

    NASA Astrophysics Data System (ADS)

    Nawalany, Marek; Sinicyn, Grzegorz

    2015-09-01

    An overview is presented of scale problems in groundwater flow, with emphasis on upscaling of hydraulic conductivity, being a brief summary of the conventional upscaling approach with some attention paid to recently emerged approaches. The focus is on essential aspects which may be an advantage in comparison to the occasionally extremely extensive summaries presented in the literature. In the present paper the concept of scale is introduced as an indispensable part of system analysis applied to hydrogeology. The concept is illustrated with a simple hydrogeological system for which definitions of four major ingredients of scale are presented: (i) spatial extent and geometry of hydrogeological system, (ii) spatial continuity and granularity of both natural and man-made objects within the system, (iii) duration of the system and (iv) continuity/granularity of natural and man-related variables of groundwater flow system. Scales used in hydrogeology are categorised into five classes: micro-scale - scale of pores, meso-scale - scale of laboratory sample, macro-scale - scale of typical blocks in numerical models of groundwater flow, local-scale - scale of an aquifer/aquitard and regional-scale - scale of series of aquifers and aquitards. Variables, parameters and groundwater flow equations for the three lowest scales, i.e., pore-scale, sample-scale and (numerical) block-scale, are discussed in detail, with the aim to justify physically deterministic procedures of upscaling from finer to coarser scales (stochastic issues of upscaling are not discussed here). Since the procedure of transition from sample-scale to block-scale is physically well based, it is a good candidate for upscaling block-scale models to local-scale models and likewise for upscaling local-scale models to regional-scale models. Also the latest results in downscaling from block-scale to sample scale are briefly referred to.

  19. Identification of ozonation by-products of 4- and 5-methyl-1H-benzotriazole during the treatment of surface water to drinking water.

    PubMed

    Müller, Alexander; Weiss, Stefan C; Beisswenger, Judith; Leukhardt, H Georg; Schulz, Wolfgang; Seitz, Wolfram; Ruck, Wolfgang K L; Weber, Walter H

    2012-03-01

    During the treatment of surface water to drinking water, ozonation is often used for disinfection and to remove organic trace substances, whereby oxidation by-products can be formed. Here we use the example of tolyltriazole to describe an approach for identifying relevant oxidation by-products in the laboratory and subsequently detecting them in an industrial-scale process. The identification process involves ozonation experiments with pure substances at laboratory level (concentration range mg L(-1)). The reaction solutions from different ozone contact times were analyzed by high performance liquid chromatography - quadrupole time-of-flight mass spectrometry (HPLC-QTOF-MS) in full scan mode. Various approaches were used to detect the oxidation by-products: (i) target searches of postulated oxidation by-products, (ii) comparisons of chromatograms (e.g., UV/VIS) of the different samples, and (iii) color-coded abundance time courses (kinetic) of all detected compounds were illustrated in a kind of a heat map. MS/MS, H/D exchange, and derivatization experiments were used for structure elucidation for the detected by-product. Due to the low contaminant concentrations (ng L(-1)-range) of contaminants in the untreated water, the conversion of results from laboratory experiments to an industrial-scale required the use of HPLC-MS/MS with sample enrichment (e.g., solid phase extraction.) In cases where reference substances were not available or oxidation by-products without clear structures were detected, reaction solutions from laboratory experiments were used to optimize the analytical method to detect ng L(-1) in the samples of the industrial processes. We exemplarily demonstrated the effectiveness of the methodology with the industrial chemicals 4- and 5-methyl-1H-benzotriazole (4- and 5-MBT) as an example. Moreover, not only did we identify several oxidation by-products in the laboratory experiments tentatively, but also detected three of the eleven reaction products in the outlet of the full-scale ozonation unit. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, D. H.; Reigel, M. M.

    A full-scale formed core sampler was designed and functionally tested for use in the Saltstone Disposal Facility (SDF). Savannah River National Laboratory (SRNL) was requested to compare properties of the formed core samples and core drilled samples taken from adjacent areas in the full-scale sampler. While several physical properties were evaluated, the primary property of interest was hydraulic conductivity. Differences in hydraulic conductivity between the samples from the formed core sampler and those representing the bulk material were noted with respect to the initial handling and storage of the samples. Due to testing conditions, the site port samples were exposedmore » to uncontrolled temperature and humidity conditions prior to testing whereas the formed core samples were kept in sealed containers with minimal exposure to an uncontrolled environment prior to testing. Based on the results of the testing, no significant differences in porosity or density were found between the formed core samples and those representing the bulk material in the test stand.« less

  1. Study on Thermal Decomposition Characteristics of Ammonium Nitrate Emulsion Explosive in Different Scales

    NASA Astrophysics Data System (ADS)

    Wu, Qiujie; Tan, Liu; Xu, Sen; Liu, Dabin; Min, Li

    2018-04-01

    Numerous accidents of emulsion explosive (EE) are attributed to uncontrolled thermal decomposition of ammonium nitrate emulsion (ANE, the intermediate of EE) and EE in large scale. In order to study the thermal decomposition characteristics of ANE and EE in different scales, a large-scale test of modified vented pipe test (MVPT), and two laboratory-scale tests of differential scanning calorimeter (DSC) and accelerating rate calorimeter (ARC) were applied in the present study. The scale effect and water effect both play an important role in the thermal stability of ANE and EE. The measured decomposition temperatures of ANE and EE in MVPT are 146°C and 144°C, respectively, much lower than those in DSC and ARC. As the size of the same sample in DSC, ARC, and MVPT successively increases, the onset temperatures decrease. In the same test, the measured onset temperature value of ANE is higher than that of EE. The water composition of the sample stabilizes the sample. The large-scale test of MVPT can provide information for the real-life operations. The large-scale operations have more risks, and continuous overheating should be avoided.

  2. Leaching assessment of road materials containing primary lead and zinc slags.

    PubMed

    Barna, R; Moszkowicz, P; Gervais, C

    2004-01-01

    Characterisation of the leaching behaviour of waste-containing materials is a crucial step in the environmental assessment for reuse scenarios. In our research we applied the multi-step European methodology ENV 12-920 to the leaching assessment of road materials containing metallurgical slag. A Zn slag from an imperial smelting furnace (ISF) and a Pb slag from a lead blast furnace (LBF) are investigated. The two slags contain up to 11.2 wt% of lead and 3.5 wt% of zinc and were introduced as a partial substitute for sand in two road materials, namely sand-cement and sand-bitumen. At the laboratory scale, a leaching assessment was performed first through batch equilibrium leaching tests. Second, the release rate of the contaminants was evaluated using saturated leaching tests on monolithic material. Third, laboratory tests were conducted on monolithic samples under intermittent wetting conditions. Pilot-scale tests were conducted for field testing of intermittent wetting conditions. The results show that the release of Pb and Zn from the materials in a saturated scenario was controlled by the pH of the leachates. For the intermittent wetting conditions, an additional factor, blocking of the pores by precipitation during the drying phase is proposed. Pilot-scale leaching behaviour only partially matched with the laboratory-scale test results: new mass transfer mechanisms and adapted laboratory leaching tests are discussed.

  3. Detection of Cryptosporidium and Giardia in clinical laboratories in Europe--a comparative study.

    PubMed

    Manser, M; Granlund, M; Edwards, H; Saez, A; Petersen, E; Evengard, B; Chiodini, P

    2014-01-01

    To determine the routine diagnostic methods used and compare the performance in detection of oocysts of Cryptosporidium species and cysts of Giardia intestinalis in faecal samples by European specialist parasitology laboratories and European clinical laboratories. Two sets of seven formalin-preserved faecal samples, one containing cysts of Giardia intestinalis and the other, containing oocysts of Cryptosporidium, were sent to 18 laboratories. Participants were asked to examine the specimens using their routine protocol for detecting these parasites and state the method(s) used. Eighteen laboratories answered the questionnaire. For detection of Giardia, 16 of them used sedimentation/concentration followed by light microscopy. Using this technique the lower limit of detection of Giardia was 17.2 cysts/mL of faeces in the best performing laboratories. Only three of 16 laboratories used fluorescent-conjugated antibody-based microscopy. For detection of Cryptosporidium acid-fast staining was used by 14 of the 17 laboratories that examined the samples. With this technique the lower limit of detection was 976 oocysts/mL of faeces. Fluorescent-conjugated antibody-based microscopy was used by only five of the 17 laboratories. There was variation in the lower limit of detection of cysts of Giardia and oocysts of Cryptosporidium between laboratories using the same basic microscopic methods. Fluorescent-conjugated antibody-based microscopy was not superior to light microscopy under the conditions of this study. There is a need for a larger-scale multi-site comparison of the methods used for the diagnosis of these parasites and the development of a Europe-wide laboratory protocol based upon its findings. © 2013 The Authors Clinical Microbiology and Infection © 2013 European Society of Clinical Microbiology and Infectious Diseases.

  4. Earthquake source properties from instrumented laboratory stick-slip

    USGS Publications Warehouse

    Kilgore, Brian D.; McGarr, Arthur F.; Beeler, Nicholas M.; Lockner, David A.; Thomas, Marion Y.; Mitchell, Thomas M.; Bhat, Harsha S.

    2017-01-01

    Stick-slip experiments were performed to determine the influence of the testing apparatus on source properties, develop methods to relate stick-slip to natural earthquakes and examine the hypothesis of McGarr [2012] that the product of stiffness, k, and slip duration, Δt, is scale-independent and the same order as for earthquakes. The experiments use the double-direct shear geometry, Sierra White granite at 2 MPa normal stress and a remote slip rate of 0.2 µm/sec. To determine apparatus effects, disc springs were added to the loading column to vary k. Duration, slip, slip rate, and stress drop decrease with increasing k, consistent with a spring-block slider model. However, neither for the data nor model is kΔt constant; this results from varying stiffness at fixed scale.In contrast, additional analysis of laboratory stick-slip studies from a range of standard testing apparatuses is consistent with McGarr's hypothesis. kΔt is scale-independent, similar to that of earthquakes, equivalent to the ratio of static stress drop to average slip velocity, and similar to the ratio of shear modulus to wavespeed of rock. These properties result from conducting experiments over a range of sample sizes, using rock samples with the same elastic properties as the Earth, and scale-independent design practices.

  5. BENCH-SCALE EVALUATION OF AMMONIA REMOVAL FROM WASTEWATER BY STEAM STRIPPING

    EPA Science Inventory

    The purpose of the study was to generate laboratory data to support the development of wastewater discharge standards for ammonia in nonferrous metal winning processes. The objective was accomplished by studying ammonia removal from synthetically compounded 'wastewater' samples u...

  6. A laboratory-scale pretreatment and hydrolysis assay for determination of reactivity in cellulosic biomass feedstocks.

    PubMed

    Wolfrum, Edward J; Ness, Ryan M; Nagle, Nicholas J; Peterson, Darren J; Scarlata, Christopher J

    2013-11-14

    The rapid determination of the release of structural sugars from biomass feedstocks is an important enabling technology for the development of cellulosic biofuels. An assay that is used to determine sugar release for large numbers of samples must be robust, rapid, and easy to perform, and must use modest amounts of the samples to be tested.In this work we present a laboratory-scale combined pretreatment and saccharification assay that can be used as a biomass feedstock screening tool. The assay uses a commercially available automated solvent extraction system for pretreatment followed by a small-scale enzymatic hydrolysis step. The assay allows multiple samples to be screened simultaneously, and uses only ~3 g of biomass per sample. If the composition of the biomass sample is known, the results of the assay can be expressed as reactivity (fraction of structural carbohydrate present in the biomass sample released as monomeric sugars). We first present pretreatment and enzymatic hydrolysis experiments on a set of representative biomass feedstock samples (corn stover, poplar, sorghum, switchgrass) in order to put the assay in context, and then show the results of the assay applied to approximately 150 different feedstock samples covering 5 different materials. From the compositional analysis data we identify a positive correlation between lignin and structural carbohydrates, and from the reactivity data we identify a negative correlation between both carbohydrate and lignin content and total reactivity. The negative correlation between lignin content and total reactivity suggests that lignin may interfere with sugar release, or that more mature samples (with higher structural sugars) may have more recalcitrant lignin. The assay presented in this work provides a robust and straightforward method to measure the sugar release after pretreatment and saccharification that can be used as a biomass feedstock screening tool. We demonstrated the utility of the assay by identifying correlations between feedstock composition and reactivity in a population of 150 samples.

  7. Implementation of a National Reference Laboratory for Buruli Ulcer Disease in Togo

    PubMed Central

    Badziklou, Kossi; Halatoko, Wemboo Afiwa; Maman, Issaka; Vogel, Felix; Bidjada, Bawimodom; Awoussi, Koffi Somenou; Piten, Ebekalisai; Helfrich, Kerstin; Mengele, Carolin; Nitschke, Jörg; Amekuse, Komi; Wiedemann, Franz Xaver; Diefenhardt, Adolf; Kobara, Basile; Herbinger, Karl–Heinz; Kere, Abiba Banla; Prince-David, Mireille; Löscher, Thomas; Bretzel, Gisela

    2013-01-01

    Background In a previous study PCR analysis of clinical samples from suspected cases of Buruli ulcer disease (BUD) from Togo and external quality assurance (EQA) for local microscopy were conducted at an external reference laboratory in Germany. The relatively poor performance of local microscopy as well as effort and time associated with shipment of PCR samples necessitated the implementation of stringent EQA measures and availability of local laboratory capacity. This study describes the approach to implementation of a national BUD reference laboratory in Togo. Methodology Large scale outreach activities accompanied by regular training programs for health care professionals were conducted in the regions “Maritime” and “Central,” standard operating procedures defined all processes in participating laboratories (regional, national and external reference laboratories) as well as the interaction between laboratories and partners in the field. Microscopy was conducted at regional level and slides were subjected to EQA at national and external reference laboratories. For PCR analysis, sample pairs were collected and subjected to a dry-reagent-based IS2404-PCR (DRB-PCR) at national level and standard IS2404 PCR followed by IS2404 qPCR analysis of negative samples at the external reference laboratory. Principal Findings The inter-laboratory concordance rates for microscopy ranged from 89% to 94%; overall, microscopy confirmed 50% of all suspected BUD cases. The inter-laboratory concordance rate for PCR was 96% with an overall PCR case confirmation rate of 78%. Compared to a previous study, the rate of BUD patients with non-ulcerative lesions increased from 37% to 50%, the mean duration of disease before clinical diagnosis decreased significantly from 182.6 to 82.1 days among patients with ulcerative lesions, and the percentage of category III lesions decreased from 30.3% to 19.2%. Conclusions High inter-laboratory concordance rates as well as case confirmation rates of 50% (microscopy), 71% (PCR at national level), and 78% (including qPCR confirmation at external reference laboratory) suggest high standards of BUD diagnostics. The increase of non-ulcerative lesions, as well as the decrease in diagnostic delay and category III lesions, prove the effect of comprehensive EQA and training measures involving also procedures outside the laboratory. PMID:23359828

  8. Implementation of a national reference laboratory for Buruli ulcer disease in Togo.

    PubMed

    Beissner, Marcus; Huber, Kristina Lydia; Badziklou, Kossi; Halatoko, Wemboo Afiwa; Maman, Issaka; Vogel, Felix; Bidjada, Bawimodom; Awoussi, Koffi Somenou; Piten, Ebekalisai; Helfrich, Kerstin; Mengele, Carolin; Nitschke, Jörg; Amekuse, Komi; Wiedemann, Franz Xaver; Diefenhardt, Adolf; Kobara, Basile; Herbinger, Karl-Heinz; Kere, Abiba Banla; Prince-David, Mireille; Löscher, Thomas; Bretzel, Gisela

    2013-01-01

    In a previous study PCR analysis of clinical samples from suspected cases of Buruli ulcer disease (BUD) from Togo and external quality assurance (EQA) for local microscopy were conducted at an external reference laboratory in Germany. The relatively poor performance of local microscopy as well as effort and time associated with shipment of PCR samples necessitated the implementation of stringent EQA measures and availability of local laboratory capacity. This study describes the approach to implementation of a national BUD reference laboratory in Togo. Large scale outreach activities accompanied by regular training programs for health care professionals were conducted in the regions "Maritime" and "Central," standard operating procedures defined all processes in participating laboratories (regional, national and external reference laboratories) as well as the interaction between laboratories and partners in the field. Microscopy was conducted at regional level and slides were subjected to EQA at national and external reference laboratories. For PCR analysis, sample pairs were collected and subjected to a dry-reagent-based IS2404-PCR (DRB-PCR) at national level and standard IS2404 PCR followed by IS2404 qPCR analysis of negative samples at the external reference laboratory. The inter-laboratory concordance rates for microscopy ranged from 89% to 94%; overall, microscopy confirmed 50% of all suspected BUD cases. The inter-laboratory concordance rate for PCR was 96% with an overall PCR case confirmation rate of 78%. Compared to a previous study, the rate of BUD patients with non-ulcerative lesions increased from 37% to 50%, the mean duration of disease before clinical diagnosis decreased significantly from 182.6 to 82.1 days among patients with ulcerative lesions, and the percentage of category III lesions decreased from 30.3% to 19.2%. High inter-laboratory concordance rates as well as case confirmation rates of 50% (microscopy), 71% (PCR at national level), and 78% (including qPCR confirmation at external reference laboratory) suggest high standards of BUD diagnostics. The increase of non-ulcerative lesions, as well as the decrease in diagnostic delay and category III lesions, prove the effect of comprehensive EQA and training measures involving also procedures outside the laboratory.

  9. Robofurnace: A semi-automated laboratory chemical vapor deposition system for high-throughput nanomaterial synthesis and process discovery

    PubMed Central

    Oliver, C. Ryan; Westrick, William; Koehler, Jeremy; Brieland-Shoultz, Anna; Anagnostopoulos-Politis, Ilias; Cruz-Gonzalez, Tizoc; Hart, A. John

    2013-01-01

    Laboratory research and development on new materials, such as nanostructured thin films, often utilizes manual equipment such as tube furnaces due to its relatively low cost and ease of setup. However, these systems can be prone to inconsistent outcomes due to variations in standard operating procedures and limitations in performance such as heating and cooling rates restrict the parameter space that can be explored. Perhaps more importantly, maximization of research throughput and the successful and efficient translation of materials processing knowledge to production-scale systems, relies on the attainment of consistent outcomes. In response to this need, we present a semi-automated lab-scale chemical vapor deposition (CVD) furnace system, called “Robofurnace.” Robofurnace is an automated CVD system built around a standard tube furnace, which automates sample insertion and removal and uses motion of the furnace to achieve rapid heating and cooling. The system has a 10-sample magazine and motorized transfer arm, which isolates the samples from the lab atmosphere and enables highly repeatable placement of the sample within the tube. The system is designed to enable continuous operation of the CVD reactor, with asynchronous loading/unloading of samples. To demonstrate its performance, Robofurnace is used to develop a rapid CVD recipe for carbon nanotube (CNT) forest growth, achieving a 10-fold improvement in CNT forest mass density compared to a benchmark recipe using a manual tube furnace. In the long run, multiple systems like Robofurnace may be linked to share data among laboratories by methods such as Twitter. Our hope is Robofurnace and like automation will enable machine learning to optimize and discover relationships in complex material synthesis processes. PMID:24289435

  10. Assessment of statistical uncertainty in the quantitative analysis of solid samples in motion using laser-induced breakdown spectroscopy

    NASA Astrophysics Data System (ADS)

    Cabalín, L. M.; González, A.; Ruiz, J.; Laserna, J. J.

    2010-08-01

    Statistical uncertainty in the quantitative analysis of solid samples in motion by laser-induced breakdown spectroscopy (LIBS) has been assessed. For this purpose, a LIBS demonstrator was designed and constructed in our laboratory. The LIBS system consisted of a laboratory-scale conveyor belt, a compact optical module and a Nd:YAG laser operating at 532 nm. The speed of the conveyor belt was variable and could be adjusted up to a maximum speed of 2 m s - 1 . Statistical uncertainty in the analytical measurements was estimated in terms of precision (reproducibility and repeatability) and accuracy. The results obtained by LIBS on shredded scrap samples under real conditions have demonstrated that the analytical precision and accuracy of LIBS is dependent on the sample geometry, position on the conveyor belt and surface cleanliness. Flat, relatively clean scrap samples exhibited acceptable reproducibility and repeatability; by contrast, samples with an irregular shape or a dirty surface exhibited a poor relative standard deviation.

  11. Body Odor Trait Disgust Sensitivity Predicts Perception of Sweat Biosamples.

    PubMed

    Liuzza, Marco Tullio; Olofsson, Jonas K; Sabiniewicz, Agnieszka; Sorokowska, Agnieszka

    2017-07-01

    Body odors are potent triggers of disgust and regulate social behaviors in many species. The role of olfaction in disgust-associated behaviors has received scant attention in the research literature, in part because olfactory disgust assessments have required laboratory testing with odors. We have devised the "Body Odor Disgust Scale" (BODS) to facilitate research on olfactory disgust. In this study, we evaluated whether individual differences in BODS scores would be associated with the perception of disgust for sweat samples in a laboratory setting. Results show that BODS was a strong predictor of disgust ratings of sweat samples even when controlling for general disgust sensitivity. In contrast, odor intensity ratings were unrelated to BODS scores. Our findings suggest that the BODS scores reflect body odor disgust perception. The BODS scale might facilitate research on olfactory disgust responses and associated behaviors. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  12. Characterization of seismic properties across scales: from the laboratory- to the field scale

    NASA Astrophysics Data System (ADS)

    Grab, Melchior; Quintal, Beatriz; Caspari, Eva; Maurer, Hansruedi; Greenhalgh, Stewart

    2016-04-01

    When exploring geothermal systems, the main interest is on factors controlling the efficiency of the heat exchanger. This includes the energy state of the pore fluids and the presence of permeable structures building part of the fluid transport system. Seismic methods are amongst the most common exploration techniques to image the deep subsurface in order to evaluate such a geothermal heat exchanger. They make use of the fact that a seismic wave caries information on the properties of the rocks in the subsurface through which it passes. This enables the derivation of the stiffness and the density of the host rock from the seismic velocities. Moreover, it is well-known that the seismic waveforms are modulated while propagating trough the subsurface by visco-elastic effects due to wave induced fluid flow, hence, delivering information about the fluids in the rock's pore space. To constrain the interpretation of seismic data, that is, to link seismic properties with the fluid state and host rock permeability, it is common practice to measure the rock properties of small rock specimens in the laboratory under in-situ conditions. However, in magmatic geothermal systems or in systems situated in the crystalline basement, the host rock is often highly impermeable and fluid transport predominately takes place in fracture networks, consisting of fractures larger than the rock samples investigated in the laboratory. Therefore, laboratory experiments only provide the properties of relatively intact rock and an up-scaling procedure is required to characterize the seismic properties of large rock volumes containing fractures and fracture networks and to study the effects of fluids in such fractured rock. We present a technique to parameterize fractured rock volumes as typically encountered in Icelandic magmatic geothermal systems, by combining laboratory experiments with effective medium calculations. The resulting models can be used to calculate the frequency-dependent bulk modulus K(ω) and shear modulus G(ω), from which the P- and S-wave velocities V P(ω) and V S(ω) and the quality factors QP(ω) and QS(ω) of fluid saturated fractured rock volumes can be estimated. These volumes are much larger and contain more complex structures than the rock samples investigated in the laboratory. Thus, the derived quantities describe the elastic and anelastic (energy loss due to wave induced fluid flow) short-term deformation induced by seismic waves at scales that are relevant for field-scale seismic exploration projects.

  13. DNA banking and DNA databanking by academic and commercial laboratories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McEwen, J.E.; Reilly, P.R.

    The advent of DNA-based testing is giving rise to DNA banking (the long-term storage of cells, transformed cell lines, or extracted DNA for subsequent retrieval and analysis) and DNA data banking (the indefinite storage of information derived from DNA analysis). Large scale acquisition and storage of DNA and DNA data has important implications for the privacy rights of individuals. A survey of 148 academically based and commercial DNA diagnostic laboratories was conducted to determine: (1) the extent of their DNA banking activities; (2) their policies and experiences regarding access to DNA samples and data; (3) the quality assurance measures theymore » employ; and (4) whether they have written policies and/or depositor`s agreements addressing specific issues. These issues include: (1) who may have access to DNA samples and data; (2) whether scientists may have access to anonymous samples or data for research use; (3) whether they have plans to contact depositors or retest samples if improved tests for a disorder become available; (4) disposition of samples at the end of the contract period if the laboratory ceases operations, if storage fees are unpaid, or after a death or divorce; (5) the consequence of unauthorized release, loss, or accidental destruction of samples; and (6) whether depositors may share in profits from the commercialization of tests or treatments developed in part from studies of stored DNA. The results suggest that many laboratories are banking DNA, that many have already amassed a large number of samples, and that a significant number plan to further develop DNA banking as a laboratory service over the next two years. Few laboratories have developed written policies governing DNA banking, and fewer still have drafted documents that define the rights and obligations of the parties. There may be a need for increased regulation of DNA banking and DNA data banking and for better defined policies with respect to protecting individual privacy.« less

  14. Improved sugar yields from biomass sorghum feedstocks: comparing low-lignin mutants and pretreatment chemistries.

    PubMed

    Godin, Bruno; Nagle, Nick; Sattler, Scott; Agneessens, Richard; Delcarte, Jérôme; Wolfrum, Edward

    2016-01-01

    For biofuel production processes to be economically efficient, it is essential to maximize the production of monomeric carbohydrates from the structural carbohydrates of feedstocks. One strategy for maximizing carbohydrate production is to identify less recalcitrant feedstock cultivars by performing some type of experimental screening on a large and diverse set of candidate materials, or by identifying genetic modifications (random or directed mutations or transgenic plants) that provide decreased recalcitrance. Economic efficiency can also be increased using additional pretreatment processes such as deacetylation, which uses dilute NaOH to remove the acetyl groups of hemicellulose prior to dilute acid pretreatment. In this work, we used a laboratory-scale screening tool that mimics relevant thermochemical pretreatment conditions to compare the total sugar yield of three near-isogenic brown midrib ( bmr ) mutant lines and the wild-type (WT) sorghum cultivar. We then compared results obtained from the laboratory-scale screening pretreatment assay to a large-scale pretreatment system. After pretreatment and enzymatic hydrolysis, the bmr mutants had higher total sugar yields than the WT sorghum cultivar. Increased pretreatment temperatures increased reactivity for all sorghum samples reducing the differences observed at lower reaction temperatures. Deacetylation prior to dilute acid pretreatment increased the total sugar yield for all four sorghum samples, and reduced the differences in total sugar yields among them, but solubilized a sizable fraction of the non-structural carbohydrates. The general trends of increased total sugar yield in the bmr mutant compared to the WT seen at the laboratory scale were observed at the large-scale system. However, in the larger reactor system, the measured total sugar yields were lower and the difference in total sugar yield between the WT and bmr sorghum was larger. Sorghum bmr mutants, which have a reduced lignin content showed higher total sugar yields than the WT cultivar after dilute acid pretreatment and enzymatic hydrolysis. Deacetylation prior to dilute acid pretreatment increased the total sugar yield for all four sorghum samples. However, since deacetylation also solubilizes a large fraction of the non-structural carbohydrates, the ability to derive value from these solubilized sugars will depend greatly on the proposed conversion process.

  15. Improved sugar yields from biomass sorghum feedstocks: comparing low-lignin mutants and pretreatment chemistries

    DOE PAGES

    Godin, Bruno; Nagle, Nick; Sattler, Scott; ...

    2016-11-21

    For biofuel production processes to be economically efficient, it is essential to maximize the production of monomeric carbohydrates from the structural carbohydrates of feedstocks. One strategy for maximizing carbohydrate production is to identify less recalcitrant feedstock cultivars by performing some type of experimental screening on a large and diverse set of candidate materials, or by identifying genetic modifications (random or directed mutations or transgenic plants) that provide decreased recalcitrance. Economic efficiency can also be increased using additional pretreatment processes such as deacetylation, which uses dilute NaOH to remove the acetyl groups of hemicellulose prior to dilute acid pretreatment. In thismore » work, we used a laboratory-scale screening tool that mimics relevant thermochemical pretreatment conditions to compare the total sugar yield of three near-isogenic brown midrib (bmr) mutant lines and the wild-type (WT) sorghum cultivar. We then compared results obtained from the laboratory-scale screening pretreatment assay to a large-scale pretreatment system. After pretreatment and enzymatic hydrolysis, the bmr mutants had higher total sugar yields than the WT sorghum cultivar. Increased pretreatment temperatures increased reactivity for all sorghum samples reducing the differences observed at lower reaction temperatures. Deacetylation prior to dilute acid pretreatment increased the total sugar yield for all four sorghum samples, and reduced the differences in total sugar yields among them, but solubilized a sizable fraction of the non-structural carbohydrates. The general trends of increased total sugar yield in the bmr mutant compared to the WT seen at the laboratory scale were observed at the large-scale system. However, in the larger reactor system, the measured total sugar yields were lower and the difference in total sugar yield between the WT and bmr sorghum was larger. Sorghum bmr mutants, which have a reduced lignin content showed higher total sugar yields than the WT cultivar after dilute acid pretreatment and enzymatic hydrolysis. In conclusion, deacetylation prior to dilute acid pretreatment increased the total sugar yield for all four sorghum samples. However, since deacetylation also solubilizes a large fraction of the non-structural carbohydrates, the ability to derive value from these solubilized sugars will depend greatly on the proposed conversion process.« less

  16. Improved sugar yields from biomass sorghum feedstocks: comparing low-lignin mutants and pretreatment chemistries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Godin, Bruno; Nagle, Nick; Sattler, Scott

    For biofuel production processes to be economically efficient, it is essential to maximize the production of monomeric carbohydrates from the structural carbohydrates of feedstocks. One strategy for maximizing carbohydrate production is to identify less recalcitrant feedstock cultivars by performing some type of experimental screening on a large and diverse set of candidate materials, or by identifying genetic modifications (random or directed mutations or transgenic plants) that provide decreased recalcitrance. Economic efficiency can also be increased using additional pretreatment processes such as deacetylation, which uses dilute NaOH to remove the acetyl groups of hemicellulose prior to dilute acid pretreatment. In thismore » work, we used a laboratory-scale screening tool that mimics relevant thermochemical pretreatment conditions to compare the total sugar yield of three near-isogenic brown midrib (bmr) mutant lines and the wild-type (WT) sorghum cultivar. We then compared results obtained from the laboratory-scale screening pretreatment assay to a large-scale pretreatment system. After pretreatment and enzymatic hydrolysis, the bmr mutants had higher total sugar yields than the WT sorghum cultivar. Increased pretreatment temperatures increased reactivity for all sorghum samples reducing the differences observed at lower reaction temperatures. Deacetylation prior to dilute acid pretreatment increased the total sugar yield for all four sorghum samples, and reduced the differences in total sugar yields among them, but solubilized a sizable fraction of the non-structural carbohydrates. The general trends of increased total sugar yield in the bmr mutant compared to the WT seen at the laboratory scale were observed at the large-scale system. However, in the larger reactor system, the measured total sugar yields were lower and the difference in total sugar yield between the WT and bmr sorghum was larger. Sorghum bmr mutants, which have a reduced lignin content showed higher total sugar yields than the WT cultivar after dilute acid pretreatment and enzymatic hydrolysis. In conclusion, deacetylation prior to dilute acid pretreatment increased the total sugar yield for all four sorghum samples. However, since deacetylation also solubilizes a large fraction of the non-structural carbohydrates, the ability to derive value from these solubilized sugars will depend greatly on the proposed conversion process.« less

  17. Multiscale properties of unconventional reservoir rocks

    NASA Astrophysics Data System (ADS)

    Woodruff, W. F.

    A multidisciplinary study of unconventional reservoir rocks is presented, providing the theory, forward modeling and Bayesian inverse modeling approaches, and laboratory protocols to characterize clay-rich, low porosity and permeability shales and mudstones within an anisotropic framework. Several physical models characterizing oil and gas shales are developed across multiple length scales, ranging from microscale phenomena, e.g. the effect of the cation exchange capacity of reactive clay mineral surfaces on water adsorption isotherms, and the effects of infinitesimal porosity compaction on elastic and electrical properties, to meso-scale phenomena, e.g. the role of mineral foliations, tortuosity of conduction pathways and the effects of organic matter (kerogen and hydrocarbon fractions) on complex conductivity and their connections to intrinsic electrical anisotropy, as well as the macro-scale electrical and elastic properties including formulations for the complex conductivity tensor and undrained stiffness tensor within the context of effective stress and poroelasticity. Detailed laboratory protocols are described for sample preparation and measurement of these properties using spectral induced polarization (SIP) and ultrasonics for the anisotropic characterization of shales for both unjacketed samples under benchtop conditions and jacketed samples under differential loading. An ongoing study of the effects of kerogen maturation through hydrous pyrolysis on the complex conductivity is also provided in review. Experimental results are catalogued and presented for various unconventional formations in North America including the Haynesville, Bakken, and Woodford shales.

  18. Non-destructive evaluation of laboratory scale hydraulic fracturing using acoustic emission

    NASA Astrophysics Data System (ADS)

    Hampton, Jesse Clay

    The primary objective of this research is to develop techniques to characterize hydraulic fractures and fracturing processes using acoustic emission monitoring based on laboratory scale hydraulic fracturing experiments. Individual microcrack AE source characterization is performed to understand the failure mechanisms associated with small failures along pre-existing discontinuities and grain boundaries. Individual microcrack analysis methods include moment tensor inversion techniques to elucidate the mode of failure, crack slip and crack normal direction vectors, and relative volumetric deformation of an individual microcrack. Differentiation between individual microcrack analysis and AE cloud based techniques is studied in efforts to refine discrete fracture network (DFN) creation and regional damage quantification of densely fractured media. Regional damage estimations from combinations of individual microcrack analyses and AE cloud density plotting are used to investigate the usefulness of weighting cloud based AE analysis techniques with microcrack source data. Two granite types were used in several sample configurations including multi-block systems. Laboratory hydraulic fracturing was performed with sample sizes ranging from 15 x 15 x 25 cm3 to 30 x 30 x 25 cm 3 in both unconfined and true-triaxially confined stress states using different types of materials. Hydraulic fracture testing in rock block systems containing a large natural fracture was investigated in terms of AE response throughout fracture interactions. Investigations of differing scale analyses showed the usefulness of individual microcrack characterization as well as DFN and cloud based techniques. Individual microcrack characterization weighting cloud based techniques correlated well with post-test damage evaluations.

  19. Normalization of oxygen and hydrogen isotope data

    USGS Publications Warehouse

    Coplen, T.B.

    1988-01-01

    To resolve confusion due to expression of isotopic data from different laboratories on non-corresponding scales, oxygen isotope analyses of all substances can be expressed relative to VSMOW or VPDB (Vienna Peedee belemnite) on scales normalized such that the ??18O of SLAP is -55.5% relative to VSMOW. H3+ contribution in hydrogen isotope ratio analysis can be easily determined using two gaseous reference samples that differ greatly in deuterium content. ?? 1988.

  20. Multiscale Porosity and Mechanical Properties of Mancos Shale: Evaluation of REV and Scale Separation

    NASA Astrophysics Data System (ADS)

    Heath, J. E.; Dewers, T. A.; Yoon, H.; Mozley, P.

    2016-12-01

    Heterogeneity from the nanometer to core and larger length scales is a major challenge to understanding coupled processes in shale. To develop methods to address this challenge, we present application of high throughput multi-beam scanning electron microscopy (mSEM) and nano-to-micro-scale mechanics to the Mancos Shale. We use a 61-beam mSEM to collect 6 nm resolution SEM images at the scale of several square millimeters. These images are analyzed for pore size and shape characteristics including spatial correlation and structure. Nano-indentation, micropillar compression, and axisymmetric testing at multiple length scales allows for examining the influence of sampling size on mechanical response. The combined data set is used to: investigate representative elementary volumes (and areas for the 2D images) for the Mancos Shale; determine if scale separation occurs; and determine if transport and mechanical properties at a given length scale can be statistically defined. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  1. Bed-Sediment Sampling and Analysis for Physical and Chemical Properties of the Lower Mississippi River near Memphis, Tennessee

    USGS Publications Warehouse

    Blanchard, Robert A.; Wagner, Daniel M.; Evans, Dennis A.

    2010-01-01

    In February 2010, the U.S. Geological Survey, in cooperation with the U.S. Army Corps of Engineers, Memphis District, investigated the presence of inorganic elements and organic compounds in bed sediments of the lower Mississippi River. Selected sites were located in the navigation channel near river miles 737, 773, and 790 near Memphis, Tennessee. Bed-sediment samples were collected using a Shipek grab sampler mounted to a boom crane with a motorized winch. Samples then were processed and shipped to the U.S. Geological Survey Sediment Laboratory in Rolla, Missouri, the USGS National Water Quality Laboratory in Denver, Colorado, and to TestAmerica Laboratory, Inc. in West Sacramento, California. Samples were analyzed for grain size, inorganic elements (including mercury), and organic compounds. Chemical results were tabulated and listed with sediment-quality guidelines and presented with the physical property results. All of the bed material samples collected during this investigation yielded concentrations that were less than the Consensus-Based Probable Effect Concentration guidelines. The physical properties were tabulated and listed using a standard U.S. Geological Survey scale of sizes by class for sediment analysis. All of the samples collected during this investigation indicated a percent composition mostly comprised of sand, ranging from less than 0.125 millimeters to less than 2 millimeters.

  2. Development of fire test methods for airplane interior materials

    NASA Technical Reports Server (NTRS)

    Tustin, E. A.

    1978-01-01

    Fire tests were conducted in a 737 airplane fuselage at NASA-JSC to characterize jet fuel fires in open steel pans (simulating post-crash fire sources and a ruptured airplane fuselage) and to characterize fires in some common combustibles (simulating in-flight fire sources). Design post-crash and in-flight fire source selections were based on these data. Large panels of airplane interior materials were exposed to closely-controlled large scale heating simulations of the two design fire sources in a Boeing fire test facility utilizing a surplused 707 fuselage section. Small samples of the same airplane materials were tested by several laboratory fire test methods. Large scale and laboratory scale data were examined for correlative factors. Published data for dangerous hazard levels in a fire environment were used as the basis for developing a method to select the most desirable material where trade-offs in heat, smoke and gaseous toxicant evolution must be considered.

  3. Modeling and Qualification of a Modified Emission Unit for Radioactive Air Emissions Stack Sampling Compliance.

    PubMed

    Barnett, J Matthew; Yu, Xiao-Ying; Recknagle, Kurtis P; Glissmeyer, John A

    2016-11-01

    A planned laboratory space and exhaust system modification to the Pacific Northwest National Laboratory Material Science and Technology Building indicated that a new evaluation of the mixing at the air sampling system location would be required for compliance to ANSI/HPS N13.1-2011. The modified exhaust system would add a third fan, thereby increasing the overall exhaust rate out the stack, thus voiding the previous mixing study. Prior to modifying the radioactive air emissions exhaust system, a three-dimensional computational fluid dynamics computer model was used to evaluate the mixing at the sampling system location. Modeling of the original three-fan system indicated that not all mixing criteria could be met. A second modeling effort was conducted with the addition of an air blender downstream of the confluence of the three fans, which then showed satisfactory mixing results. The final installation included an air blender, and the exhaust system underwent full-scale tests to verify velocity, cyclonic flow, gas, and particulate uniformity. The modeling results and those of the full-scale tests show agreement between each of the evaluated criteria. The use of a computational fluid dynamics code was an effective aid in the design process and allowed the sampling system to remain in its original location while still meeting the requirements for sampling at a well mixed location.

  4. Quality assurance and quality control in light stable isotope laboratories: A case study of Rio Grande, Texas, water samples

    USGS Publications Warehouse

    Coplen, T.B.; Qi, H.

    2009-01-01

    New isotope laboratories can achieve the goal of reporting the same isotopic composition within analytical uncertainty for the same material analysed decades apart by (1) writing their own acceptance testing procedures and putting them into their mass spectrometric or laser-based isotope-ratio equipment procurement contract, (2) requiring a manufacturer to demonstrate acceptable performance using all sample ports provided with the instrumentation, (3) for each medium to be analysed, prepare two local reference materials substantially different in isotopic composition to encompass the range in isotopic composition expected in the laboratory and calibrated them with isotopic reference materials available from the International Atomic Energy Agency (IAEA) or the US National Institute of Standards and Technology (NIST), (4) using the optimum storage containers (for water samples, sealing in glass ampoules that are sterilised after sealing is satisfactory), (5) interspersing among sample unknowns local laboratory isotopic reference materials daily (internationally distributed isotopic reference materials can be ordered at three-year intervals, and can be used for elemental analyser analyses and other analyses that consume less than 1 mg of material) - this process applies to H, C, N, O, and S isotope ratios, (6) calculating isotopic compositions of unknowns by normalising isotopic data to that of local reference materials, which have been calibrated to internationally distributed isotopic reference materials, (7) reporting results on scales normalised to internationally distributed isotopic reference materials (where they are available) and providing to sample submitters the isotopic compositions of internationally distributed isotopic reference materials of the same substance had they been analysed with unknowns, (8) providing an audit trail in the laboratory for analytical results - this trail commonly will be in electronic format and might include a laboratory information management system, (9) making at regular intervals a complete backup of laboratory analytical data (both of samples logged into the laboratory and of mass spectrometric analyses), being sure to store one copy of this backup offsite, and (10) participating in interlaboratory comparison exercises sponsored by the IAEA and other agencies at regular intervals. ?? Taylor & Francis.

  5. Deepest Trenching at Phoenix Site on Mars

    NASA Technical Reports Server (NTRS)

    2008-01-01

    NASA's Phoenix Mars Lander widened the deepest trench it has excavated, dubbed 'Stone Soup,' (in the lower half of this image) to collect a sample from about 18 centimeters (7 inches) below the surface for analysis by the lander's wet chemistry laboratory.

    Phoenix's Surface Stereo Imager took this image on Sol 95 (Aug. 30, 2008), the 95th Martian day since landing. For scale, the rock to the right of the Stone Soup trench is about 15 centimeters (6 inches) across. The lander's robotic arm scooped up a sample from the left half of the trench for delivery the following sol to the wet chemistry laboratory.

    The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  6. LIMS for Lasers 2015 for achieving long-term accuracy and precision of δ2H, δ17O, and δ18O of waters using laser absorption spectrometry

    USGS Publications Warehouse

    Coplen, Tyler B.; Wassenaar, Leonard I

    2015-01-01

    Although laser absorption spectrometry (LAS) instrumentation is easy to use, its incorporation into laboratory operations is not easy, owing to extensive offline manipulation of comma-separated-values files for outlier detection, between-sample memory correction, nonlinearity (δ-variation with water amount) correction, drift correction, normalization to VSMOW-SLAP scales, and difficulty in performing long-term QA/QC audits. METHODS: A Microsoft Access relational-database application, LIMS (Laboratory Information Management System) for Lasers 2015, was developed. It automates LAS data corrections and manages clients, projects, samples, instrument-sample lists, and triple-isotope (δ(17) O, δ(18) O, and δ(2) H values) instrumental data for liquid-water samples. It enables users to (1) graphically evaluate sample injections for variable water yields and high isotope-delta variance; (2) correct for between-sample carryover, instrumental drift, and δ nonlinearity; and (3) normalize final results to VSMOW-SLAP scales. RESULTS: Cost-free LIMS for Lasers 2015 enables users to obtain improved δ(17) O, δ(18) O, and δ(2) H values with liquid-water LAS instruments, even those with under-performing syringes. For example, LAS δ(2) HVSMOW measurements of USGS50 Lake Kyoga (Uganda) water using an under-performing syringe having ±10 % variation in water concentration gave +31.7 ± 1.6 ‰ (2-σ standard deviation), compared with the reference value of +32.8 ± 0.4 ‰, after correction for variation in δ value with water concentration, between-sample memory, and normalization to the VSMOW-SLAP scale. CONCLUSIONS: LIMS for Lasers 2015 enables users to create systematic, well-founded instrument templates, import δ(2) H, δ(17) O, and δ(18) O results, evaluate performance with automatic graphical plots, correct for δ nonlinearity due to variable water concentration, correct for between-sample memory, adjust for drift, perform VSMOW-SLAP normalization, and perform long-term QA/QC audits easily.

  7. Airborne particles released by crushing CNT composites

    NASA Astrophysics Data System (ADS)

    Ogura, I.; Okayama, C.; Kotake, M.; Ata, S.; Matsui, Y.; Gotoh, K.

    2017-06-01

    We investigated airborne particles released as a result of crushing carbon nanotube (CNT) composites using a laboratory scale crusher with rotor blades. For each crushing test, five pellets (approximately 0.1 g) of a polymer (polystyrene, polyamide, or polycarbonate) containing multiwall CNTs (Nanocyl NC7000 or CNano Flotube9000) or no CNTs were placed in the container of the crusher. The airborne particles released by the crushing of the samples were measured. The real-time aerosol measurements showed increases in the concentration of nanometer- and micrometer-sized particles, regardless of the sample type, even when CNT-free polymers were crushed. The masses of the airborne particles collected on filters were below the detection limit, which indicated that the mass ratios of the airborne particles to the crushed pellets were lower than 0.02%. In the electron microscopic analysis, particles with protruding CNTs were observed. However, free-standing CNTs were not found, except for a poorly dispersed CNT-polystyrene composite. This study demonstrated that the crushing test using a laboratory scale crusher is capable of evaluating the potential release of CNTs as a result of crushing CNT composites. The advantage of this method is that only a small amount of sample (several pieces of pellets) is required.

  8. Manual versus automated γ-H2AX foci analysis across five European laboratories: can this assay be used for rapid biodosimetry in a large scale radiation accident?

    PubMed

    Rothkamm, Kai; Barnard, Stephen; Ainsbury, Elizabeth A; Al-Hafidh, Jenna; Barquinero, Joan-Francesc; Lindholm, Carita; Moquet, Jayne; Perälä, Marjo; Roch-Lefèvre, Sandrine; Scherthan, Harry; Thierens, Hubert; Vral, Anne; Vandersickel, Veerle

    2013-08-30

    The identification of severely exposed individuals and reassurance of the 'worried well' are of prime importance for initial triage following a large scale radiation accident. We aim to develop the γ-H2AX foci assay into a rapid biomarker tool for use in accidents. Here, five laboratories established a standard operating procedure and analysed 100 ex vivo γ-irradiated, 4 or 24h incubated and overnight-shipped lymphocyte samples from four donors to generate γ-H2AX reference data, using manual and/or automated foci scoring strategies. In addition to acute, homogeneous exposures to 0, 1, 2 and 4Gy, acute simulated partial body (4Gy to 50% of cells) and protracted exposures (4Gy over 24h) were analysed. Data from all laboratories could be satisfactorily fitted with linear dose response functions. Average yields observed at 4h post exposure were 2-4 times higher than at 24h and varied considerably between laboratories. Automated scoring caused larger uncertainties than manual scoring and was unable to identify partial exposures, which were detectable in manually scored samples due to their overdispersed foci distributions. Protracted exposures were detectable but doses could not be accurately estimated with the γ-H2AX assay. We conclude that the γ-H2AX assay may be useful for rapid triage following a recent acute radiation exposure. The potentially higher speed and convenience of automated relative to manual foci scoring needs to be balanced against its compromised accuracy and inability to detect partial body exposures. Regular re-calibration or inclusion of reference samples may be necessary to ensure consistent results between laboratories or over long time periods. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  9. Preparation and physical characterization of pure beta-carotene.

    PubMed

    Laughlin, Robert G; Bunke, Gregory M; Eads, Charles D; Laidig, William D; Shelley, John C

    2002-05-01

    Pure all-trans beta-carotene has been prepared on the 10's of grams scale by isothermal Fractional Dissolution (FD) of commercial laboratory samples in tetrahydrofuran (THF). beta-Carotene purified in this way is black, with a faint brownish tinge. The electronic spectra of black samples extend into the near infrared, with end-absorption past 750 nm. Black samples react directly with dioxygen under mild conditions to yield the familiar orange or red powders. Pure beta-carotene rigorously obeys Beer's Law in octane over the entire UV-Vis spectral range, while commercial laboratory samples and recrystallized samples do not. NMR self-diffusion coefficient data demonstrate that beta-carotene exists as simple molecular solutions in octane and toluene. The anomalously high crystallinity of beta-carotene can be attributed (from analysis using molecular mechanics) to the facts that: (1) the number of theoretically possible conformers of beta-carotene is extremely small, and (2) only a small fraction of these (ca. 12%, or 127) may actually exist in fluid phases.

  10. Everyday social and conversation applications of theory-of-mind understanding by children with autism-spectrum disorders or typical development.

    PubMed

    Peterson, Candida C; Garnett, Michelle; Kelly, Adrian; Attwood, Tony

    2009-02-01

    Children with autism-spectrum disorders (ASD) often fail laboratory false-belief tests of theory of mind (ToM). Yet how this impacts on their everyday social behavior is less clear, partly owing to uncertainty over which specific everyday conversational and social skills require ToM understanding. A new caregiver-report scale of these everyday applications of ToM was developed and validated in two studies. Study 1 obtained parent ratings of 339 children (85 with autism; 230 with Asperger's; 24 typically-developing) on the new scale and results revealed (a) that the scale had good psychometric properties and (b) that children with ASD had significantly more everyday mindreading difficulties than typical developers. In Study 2, we directly tested links between laboratory ToM and everyday mindreading using teacher ratings on the new scale. The sample of 25 children included 15 with autism and 10 typical developers aged 5-12 years. Children in both groups who passed laboratory ToM tests had fewer everyday mindreading difficulties than those of the same diagnosis who failed. Yet, intriguingly, autistic ToM-passers still had more problems with everyday mindreading than younger typically-developing ToM-failers. The possible roles of family conversation and peer interaction, along with ToM, in everyday social functioning were considered.

  11. The Subsurface Flow and Transport Laboratory: A New Department of Energy User's Facility for Intermediate-Scale Experimentation

    NASA Astrophysics Data System (ADS)

    Wietsma, T. W.; Oostrom, M.; Foster, N. S.

    2003-12-01

    Intermediate-scale experiments (ISEs) for flow and transport are a valuable tool for simulating subsurface features and conditions encountered in the field at government and private sites. ISEs offer the ability to study, under controlled laboratory conditions, complicated processes characteristic of mixed wastes and heterogeneous subsurface environments, in multiple dimensions and at different scales. ISEs may, therefore, result in major cost savings if employed prior to field studies. A distinct advantage of ISEs is that researchers can design physical and/or chemical heterogeneities in the porous media matrix that better approximate natural field conditions and therefore address research questions that contain the additional complexity of processes often encountered in the natural environment. A new Subsurface Flow and Transport Laboratory (SFTL) has been developed for ISE users in the Environmental Spectroscopy & Biogeochemistry Facility in the Environmental Molecular Sciences Laboratory (EMSL) at Pacific Northwest National Laboratory (PNNL). The SFTL offers a variety of columns and flow cells, a new state-of-the-art dual-energy gamma system, a fully automated saturation-pressure apparatus, and analytical equipment for sample processing. The new facility, including qualified staff, is available for scientists interested in collaboration on conducting high-quality flow and transport experiments, including contaminant remediation. Close linkages exist between the SFTL and numerical modelers to aid in experimental design and interpretation. This presentation will discuss the facility and outline the procedures required to submit a proposal to use this unique facility for research purposes. The W. R. Wiley Environmental Molecular Sciences Laboratory, a national scientific user facility, is sponsored by the U.S. Department of Energy's Office of Biological and Environmental Research and located at Pacific Northwest National Laboratory.

  12. Corrosion and scaling potential in drinking water distribution system of tabriz, northwestern iran.

    PubMed

    Taghipour, Hassan; Shakerkhatibi, Mohammad; Pourakbar, Mojtaba; Belvasi, Mehdi

    2012-01-01

    This paper discusses the corrosion and scaling potential of Tabriz drinking water distribution system in Northwest of Iran. Internal corrosion of piping is a serious problem in drinking water industry. Corrosive water can cause intrusion of heavy metals especially lead in to water, therefore effecting public health. The aim of this study was to determine corrosion and scaling potential in potable water distribution system of Tabriz during the spring and summer in 2011. This study was carried out using Langlier Saturation Index, Ryznar Stability Index, Puckorius Scaling Index, and Aggressiveness indices. Eighty samples were taken from all over the city within two seasons, spring, and summer. Related parameters including temperature, pH, total dissolved solids, calcium hardness, and total alkalinity in all samples were measured in laboratory according to standard method manual. For the statistical analysis of the results, SPSS software (version 11.5) was used The mean and standard deviation values of Langlier, Ryznar, Puckorius and Aggressiveness Indices were equal to -0.68 (±0.43), 8.43 (±0.55), 7.86 (±0.36) and 11.23 (±0.43), respectively. By survey of corrosion indices, it was found that Tabriz drinking water is corrosive. In order to corrosion control, it is suggested that laboratorial study with regard to the distribution system condition be carried out to adjust effective parameters such as pH.

  13. Augmenting comprehension of geological relationships by integrating 3D laser scanned hand samples within a GIS environment

    NASA Astrophysics Data System (ADS)

    Harvey, A. S.; Fotopoulos, G.; Hall, B.; Amolins, K.

    2017-06-01

    Geological observations can be made on multiple scales, including micro- (e.g. thin section), meso- (e.g. hand-sized to outcrop) and macro- (e.g. outcrop and larger) scales. Types of meso-scale samples include, but are not limited to, rocks (including drill cores), minerals, and fossils. The spatial relationship among samples paired with physical (e.g. granulometric composition, density, roughness) and chemical (e.g. mineralogical and isotopic composition) properties can aid in interpreting geological settings, such as paleo-environmental and formational conditions as well as geomorphological history. Field samples are collected along traverses in the area of interest based on characteristic representativeness of a region, predetermined rate of sampling, and/or uniqueness. The location of a sample can provide relative context in seeking out additional key samples. Beyond labelling and recording of geospatial coordinates for samples, further analysis of physical and chemical properties may be conducted in the field and laboratory. The main motivation for this paper is to present a workflow for the digital preservation of samples (via 3D laser scanning) paired with the development of cyber infrastructure, which offers geoscientists and engineers the opportunity to access an increasingly diverse worldwide collection of digital Earth materials. This paper describes a Web-based graphical user interface developed using Web AppBuilder for ArcGIS for digitized meso-scale 3D scans of geological samples to be viewed alongside the macro-scale environment. Over 100 samples of virtual rocks, minerals and fossils populate the developed geological database and are linked explicitly with their associated attributes, characteristic properties, and location. Applications of this new Web-based geological visualization paradigm in the geosciences demonstrate the utility of such a tool in an age of increasing global data sharing.

  14. SaDA: From Sampling to Data Analysis—An Extensible Open Source Infrastructure for Rapid, Robust and Automated Management and Analysis of Modern Ecological High-Throughput Microarray Data

    PubMed Central

    Singh, Kumar Saurabh; Thual, Dominique; Spurio, Roberto; Cannata, Nicola

    2015-01-01

    One of the most crucial characteristics of day-to-day laboratory information management is the collection, storage and retrieval of information about research subjects and environmental or biomedical samples. An efficient link between sample data and experimental results is absolutely important for the successful outcome of a collaborative project. Currently available software solutions are largely limited to large scale, expensive commercial Laboratory Information Management Systems (LIMS). Acquiring such LIMS indeed can bring laboratory information management to a higher level, but most of the times this requires a sufficient investment of money, time and technical efforts. There is a clear need for a light weighted open source system which can easily be managed on local servers and handled by individual researchers. Here we present a software named SaDA for storing, retrieving and analyzing data originated from microorganism monitoring experiments. SaDA is fully integrated in the management of environmental samples, oligonucleotide sequences, microarray data and the subsequent downstream analysis procedures. It is simple and generic software, and can be extended and customized for various environmental and biomedical studies. PMID:26047146

  15. SaDA: From Sampling to Data Analysis-An Extensible Open Source Infrastructure for Rapid, Robust and Automated Management and Analysis of Modern Ecological High-Throughput Microarray Data.

    PubMed

    Singh, Kumar Saurabh; Thual, Dominique; Spurio, Roberto; Cannata, Nicola

    2015-06-03

    One of the most crucial characteristics of day-to-day laboratory information management is the collection, storage and retrieval of information about research subjects and environmental or biomedical samples. An efficient link between sample data and experimental results is absolutely important for the successful outcome of a collaborative project. Currently available software solutions are largely limited to large scale, expensive commercial Laboratory Information Management Systems (LIMS). Acquiring such LIMS indeed can bring laboratory information management to a higher level, but most of the times this requires a sufficient investment of money, time and technical efforts. There is a clear need for a light weighted open source system which can easily be managed on local servers and handled by individual researchers. Here we present a software named SaDA for storing, retrieving and analyzing data originated from microorganism monitoring experiments. SaDA is fully integrated in the management of environmental samples, oligonucleotide sequences, microarray data and the subsequent downstream analysis procedures. It is simple and generic software, and can be extended and customized for various environmental and biomedical studies.

  16. Local versus field scale soil heterogeneity characterization - a challenge for representative sampling in pollution studies

    NASA Astrophysics Data System (ADS)

    Kardanpour, Z.; Jacobsen, O. S.; Esbensen, K. H.

    2015-06-01

    This study is a contribution to development of a heterogeneity characterisation facility for "next generation" sampling aimed at more realistic and controllable pesticide variability in laboratory pots in experimental environmental contaminant assessment. The role of soil heterogeneity on quantification of a set of exemplar parameters, organic matter, loss on ignition (LOI), biomass, soil microbiology, MCPA sorption and mineralization is described, including a brief background on how heterogeneity affects sampling/monitoring procedures in environmental pollutant studies. The Theory of Sampling (TOS) and variographic analysis has been applied to develop a fit-for-purpose heterogeneity characterization approach. All parameters were assessed in large-scale profile (1-100 m) vs. small-scale (0.1-1 m) replication sampling pattern. Variographic profiles of experimental analytical results concludes that it is essential to sample at locations with less than a 2.5 m distance interval to benefit from spatial auto-correlation and thereby avoid unnecessary, inflated compositional variation in experimental pots; this range is an inherent characteristic of the soil heterogeneity and will differ among soils types. This study has a significant carrying-over potential for related research areas e.g. soil science, contamination studies, and environmental monitoring and environmental chemistry.

  17. Multitemporal Three Dimensional Imaging of Volcanic Products on the Macro- and Micro- Scale

    NASA Astrophysics Data System (ADS)

    Carter, A. J.; Ramsey, M. S.; Durant, A. J.; Skilling, I. P.

    2006-12-01

    Satellite data from the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) can be processed using a nadir- and backward-viewing band at the same wavelength to generate a Digital Elevation Model (DEM) at a maximum spatial resolution of 15 metres. Bezymianny Volcano (Kamchatka Peninsula, Russia) was chosen as a test target for multitemporal DEM generation. DEMs were used to generate a layer stack and calculate coarse topographic changes from 2000 to 2006, the most significant of which was a new crater that formed in spring 2005. The eruption that occurred on 11 January 2005 produced a pyroclastic deposit on the east flank, which was mapped and from which samples were collected in August 2005. A comparison was made between field-based observations of the deposit and micron-scale roughness (analogous to vesicularity) derived from ASTER thermal infrared data following the model described in Ramsey and Fink (1999) on lava domes. In order to investigate applying this technique to the pyroclastic deposits, 18 small samples from Bezymianny were selected for Scanning Electron Microscope (SEM) micron-scale analysis. The SEM image data were processed using software capable of calculating surface roughness and vesicle volume from stereo pairs: a statistical analysis of samples is presented using a high resolution grid of surface profiles. The results allow for a direct comparison to field, laboratory, and satellite-based estimates of micron-scale roughness. Prior to SEM processing, laboratory thermal emission spectra of the microsamples were collected and modelled to estimate vesicularity. Each data set was compared and assessed for coherence within the limitations of each technique. This study outlines the value of initially imaging at the macro-scale to assess major topographic changes over time at the volcano. This is followed by an example of the application of micro-scale SEM imaging and spectral deconvolution, highlighting the advantages of using multiple resolutions to analyse frequently overlapping products at Bezymianny.

  18. Evaluation of Preanalytical Quality Indicators by Six Sigma and Pareto`s Principle.

    PubMed

    Kulkarni, Sweta; Ramesh, R; Srinivasan, A R; Silvia, C R Wilma Delphine

    2018-01-01

    Preanalytical steps are the major sources of error in clinical laboratory. The analytical errors can be corrected by quality control procedures but there is a need for stringent quality checks in preanalytical area as these processes are done outside the laboratory. Sigma value depicts the performance of laboratory and its quality measures. Hence in the present study six sigma and Pareto principle was applied to preanalytical quality indicators to evaluate the clinical biochemistry laboratory performance. This observational study was carried out for a period of 1 year from November 2015-2016. A total of 1,44,208 samples and 54,265 test requisition forms were screened for preanalytical errors like missing patient information, sample collection details in forms and hemolysed, lipemic, inappropriate, insufficient samples and total number of errors were calculated and converted into defects per million and sigma scale. Pareto`s chart was drawn using total number of errors and cumulative percentage. In 75% test requisition forms diagnosis was not mentioned and sigma value of 0.9 was obtained and for other errors like sample receiving time, stat and type of sample sigma values were 2.9, 2.6, and 2.8 respectively. For insufficient sample and improper ratio of blood to anticoagulant sigma value was 4.3. Pareto`s chart depicts out of 80% of errors in requisition forms, 20% is contributed by missing information like diagnosis. The development of quality indicators, application of six sigma and Pareto`s principle are quality measures by which not only preanalytical, the total testing process can be improved.

  19. LUNAR SAMPLES - APOLLO 11 - MSC

    NASA Image and Video Library

    1969-07-28

    S69-45025 (27 July 1969) --- This is the first lunar sample that was photographed in detail in the Lunar Receiving Laboratory at the Manned Spacecraft Center. The photograph shows a granular, fine-grained, mafic (iron magnesium rich) rock. At this early stage of the examination, this rock appears similar to several igneous rock types found on Earth. The scale is printed backwards due to the photographic configuration in the Vacuum Chamber. The sample number is 10003. This rock was among the samples collected by astronauts Neil A. Armstrong and Edwin E. Aldrin Jr. during their lunar surface extravehicular activity on July 20, 1969.

  20. Design for mosquito abundance, diversity, and phenology sampling within the National Ecological Observatory Network

    USGS Publications Warehouse

    Hoekman, D.; Springer, Yuri P.; Barker, C.M.; Barrera, R.; Blackmore, M.S.; Bradshaw, W.E.; Foley, D. H.; Ginsberg, Howard; Hayden, M. H.; Holzapfel, C. M.; Juliano, S. A.; Kramer, L. D.; LaDeau, S. L.; Livdahl, T. P.; Moore, C. G.; Nasci, R.S.; Reisen, W.K.; Savage, H. M.

    2016-01-01

    The National Ecological Observatory Network (NEON) intends to monitor mosquito populations across its broad geographical range of sites because of their prevalence in food webs, sensitivity to abiotic factors and relevance for human health. We describe the design of mosquito population sampling in the context of NEON’s long term continental scale monitoring program, emphasizing the sampling design schedule, priorities and collection methods. Freely available NEON data and associated field and laboratory samples, will increase our understanding of how mosquito abundance, demography, diversity and phenology are responding to land use and climate change.

  1. Variations of the petrophysical properties of rocks with increasing hydrocarbons content and their implications at larger scale: insights from the Majella reservoir (Italy)

    NASA Astrophysics Data System (ADS)

    Trippetta, Fabio; Ruggieri, Roberta; Lipparini, Lorenzo

    2016-04-01

    Crustal processes such as deformations or faulting are strictly related to the petrophysical properties of involved rocks. These properties depend on mineral composition, fabric, pores and any secondary features such as cracks or infilling material that may have been introduced during the whole diagenetic and tectonic history of the rock. In this work we investigate the role of hydrocarbons (HC) in changing the petrophysical properties of rock by merging laboratory experiments, well data and static models focusing on the carbonate-bearing Majella reservoir. This reservoir represent an interesting analogue for the several oil fields discovered in the subsurface in the region, allowing a comparison of a wide range of geological and geophysical data at different scale. The investigated lithology is made of high porosity ramp calcarenites, structurally slightly affected by a superimposed fracture system and displaced by few major normal faults, with some minor strike-slip movements. Sets of rock specimens were selected in the field and in particular two groups were investigated: 1. clean rocks (without oil) and 2. HC bearing rocks (with different saturations). For both groups, density, porosity, P and S wave velocity, permeability and elastic moduli measurements at increasing confining pressure were conducted on cylindrical specimens at the HP-HT Laboratory of the Istituto Nazionale di Geofisica e Vulcanologia (INGV) in Rome, Italy. For clean samples at ambient pressure, laboratory porosity varies from 10 % up to 26 % and P wave velocity (Vp) spans from 4,1 km/s to 4,9 km/s and a very good correlation between Vp, Vs and porosity is observed. The P wave velocity at 100 MPa of confining pressure, ranges between 4,5 km/s and 5,2 km/s with a pressure independent Vp/Vs ratio of about 1,9. The presence of HC within the samples affects both Vp and Vs. In particular velocities increase with the presence of hydrocarbons proportionally respect to the amount of the filled porosity. Preliminary data also suggest a different behaviour at increasing confining pressure for clean and-oil bearing samples: almost perfectly elastic behaviour for oil-bearing samples and more inelastic behaviours for cleaner samples. Thus HC presence appears to contrast the increase of confining pressure acting as semi-fluids, reducing the rock inelastic compaction and enhancing its elastic behaviour. Trying to upscale our rock-physics results, we started from wells and laboratory data on stratigraphy, porosity and Vp in order to simulate the effect of the HC presence at larger scale, using Petrel® software. The developed synthetic model highlights that Vp, which is primarily controlled by porosity, changes significantly within oil-bearing portions, with a notable impact on the velocity model that should be adopted. Moreover we are currently performing laboratory tests in order to evaluate the changes in the elastic parameters with the aim of modelling the effects of the HC on the mechanical behaviour of the involved rocks at larger scale.

  2. Thawing of ice in porous space of building materials: Experimental monitoring and computational modelling

    NASA Astrophysics Data System (ADS)

    Kočí, Jan; Maděra, Jiří; Kočí, Václav; Hlaváčová, Zuzana; Černý, Robert

    2017-11-01

    A simple laboratory experiment for the determination of thermal response of a studied sample during thawing is described in the paper. The sample made of autoclaved aerated concrete was partially water saturated and frozen. Then, the temperature development during thawing was recorded, allowing to identify the time scale of the phase change process taking place inside the sample. The experimental data was then used in the inverse analysis, in order to find unknown parameters of the smoothed effective specific heat capacity model.

  3. Automated Classification and Analysis of Non-metallic Inclusion Data Sets

    NASA Astrophysics Data System (ADS)

    Abdulsalam, Mohammad; Zhang, Tongsheng; Tan, Jia; Webler, Bryan A.

    2018-05-01

    The aim of this study is to utilize principal component analysis (PCA), clustering methods, and correlation analysis to condense and examine large, multivariate data sets produced from automated analysis of non-metallic inclusions. Non-metallic inclusions play a major role in defining the properties of steel and their examination has been greatly aided by automated analysis in scanning electron microscopes equipped with energy dispersive X-ray spectroscopy. The methods were applied to analyze inclusions on two sets of samples: two laboratory-scale samples and four industrial samples from a near-finished 4140 alloy steel components with varying machinability. The laboratory samples had well-defined inclusions chemistries, composed of MgO-Al2O3-CaO, spinel (MgO-Al2O3), and calcium aluminate inclusions. The industrial samples contained MnS inclusions as well as (Ca,Mn)S + calcium aluminate oxide inclusions. PCA could be used to reduce inclusion chemistry variables to a 2D plot, which revealed inclusion chemistry groupings in the samples. Clustering methods were used to automatically classify inclusion chemistry measurements into groups, i.e., no user-defined rules were required.

  4. Transcriptomics as a tool for assessing the scalability of mammalian cell perfusion systems.

    PubMed

    Jayapal, Karthik P; Goudar, Chetan T

    2014-01-01

    DNA microarray-based transcriptomics have been used to determine the time course of laboratory and manufacturing-scale perfusion bioreactors in an attempt to characterize cell physiological state at these two bioreactor scales. Given the limited availability of genomic data for baby hamster kidney (BHK) cells, a Chinese hamster ovary (CHO)-based microarray was used following a feasibility assessment of cross-species hybridization. A heat shock experiment was performed using both BHK and CHO cells and resulting DNA microarray data were analyzed using a filtering criteria of perfect match (PM)/single base mismatch (MM) > 1.5 and PM-MM > 50 to exclude probes with low specificity or sensitivity for cross-species hybridizations. For BHK cells, 8910 probe sets (39 %) passed the cutoff criteria, whereas 12,961 probe sets (56 %) passed the cutoff criteria for CHO cells. Yet, the data from BHK cells allowed distinct clustering of heat shock and control samples as well as identification of biologically relevant genes as being differentially expressed, indicating the utility of cross-species hybridization. Subsequently, DNA microarray analysis was performed on time course samples from laboratory- and manufacturing-scale perfusion bioreactors that were operated under the same conditions. A majority of the variability (37 %) was associated with the first principal component (PC-1). Although PC-1 changed monotonically with culture duration, the trends were very similar in both the laboratory and manufacturing-scale bioreactors. Therefore, despite time-related changes to the cell physiological state, transcriptomic fingerprints were similar across the two bioreactor scales at any given instance in culture. Multiple genes were identified with time-course expression profiles that were very highly correlated (> 0.9) with bioprocess variables of interest. Although the current incomplete annotation limits the biological interpretation of these observations, their full potential may be realized in due course when richer genomic data become available. By taking a pragmatic approach of transcriptome fingerprinting, we have demonstrated the utility of systems biology to support the comparability of laboratory and manufacturing-scale perfusion systems. Scale-down model qualification is the first step in process characterization and hence is an integral component of robust regulatory filings. Augmenting the current paradigm, which relies primarily on cell culture and product quality information, with gene expression data can help make a substantially stronger case for similarity. With continued advances in systems biology approaches, we expect them to be seamlessly integrated into bioprocess development, which can translate into more robust and high yielding processes that can ultimately reduce cost of care for patients.

  5. Bioreactor Scalability: Laboratory-Scale Bioreactor Design Influences Performance, Ecology, and Community Physiology in Expanded Granular Sludge Bed Bioreactors

    PubMed Central

    Connelly, Stephanie; Shin, Seung G.; Dillon, Robert J.; Ijaz, Umer Z.; Quince, Christopher; Sloan, William T.; Collins, Gavin

    2017-01-01

    Studies investigating the feasibility of new, or improved, biotechnologies, such as wastewater treatment digesters, inevitably start with laboratory-scale trials. However, it is rarely determined whether laboratory-scale results reflect full-scale performance or microbial ecology. The Expanded Granular Sludge Bed (EGSB) bioreactor, which is a high-rate anaerobic digester configuration, was used as a model to address that knowledge gap in this study. Two laboratory-scale idealizations of the EGSB—a one-dimensional and a three- dimensional scale-down of a full-scale design—were built and operated in triplicate under near-identical conditions to a full-scale EGSB. The laboratory-scale bioreactors were seeded using biomass obtained from the full-scale bioreactor, and, spent water from the distillation of whisky from maize was applied as substrate at both scales. Over 70 days, bioreactor performance, microbial ecology, and microbial community physiology were monitored at various depths in the sludge-beds using 16S rRNA gene sequencing (V4 region), specific methanogenic activity (SMA) assays, and a range of physical and chemical monitoring methods. SMA assays indicated dominance of the hydrogenotrophic pathway at full-scale whilst a more balanced activity profile developed during the laboratory-scale trials. At each scale, Methanobacterium was the dominant methanogenic genus present. Bioreactor performance overall was better at laboratory-scale than full-scale. We observed that bioreactor design at laboratory-scale significantly influenced spatial distribution of microbial community physiology and taxonomy in the bioreactor sludge-bed, with 1-D bioreactor types promoting stratification of each. In the 1-D laboratory bioreactors, increased abundance of Firmicutes was associated with both granule position in the sludge bed and increased activity against acetate and ethanol as substrates. We further observed that stratification in the sludge-bed in 1-D laboratory-scale bioreactors was associated with increased richness in the underlying microbial community at species (OTU) level and improved overall performance. PMID:28507535

  6. The WHO/PEPFAR collaboration to prepare an operations manual for HIV prevention, care, and treatment at primary health centers in high-prevalence, resource-constrained settings: defining laboratory services.

    PubMed

    Spira, Thomas; Lindegren, Mary Lou; Ferris, Robert; Habiyambere, Vincent; Ellerbrock, Tedd

    2009-06-01

    The expansion of HIV/AIDS care and treatment in resource-constrained countries, especially in sub-Saharan Africa, has generally developed in a top-down manner. Further expansion will involve primary health centers where human and other resources are limited. This article describes the World Health Organization/President's Emergency Plan for AIDS Relief collaboration formed to help scale up HIV services in primary health centers in high-prevalence, resource-constrained settings. It reviews the contents of the Operations Manual developed, with emphasis on the Laboratory Services chapter, which discusses essential laboratory services, both at the center and the district hospital level, laboratory safety, laboratory testing, specimen transport, how to set up a laboratory, human resources, equipment maintenance, training materials, and references. The chapter provides specific information on essential tests and generic job aids for them. It also includes annexes containing a list of laboratory supplies for the health center and sample forms.

  7. Correlations between homologue concentrations of PCDD/Fs and toxic equivalency values in laboratory-, package boiler-, and field-scale incinerators.

    PubMed

    Iino, Fukuya; Takasuga, Takumi; Touati, Abderrahmane; Gullett, Brian K

    2003-01-01

    The toxic equivalency (TEQ) values of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) are predicted with a model based on the homologue concentrations measured from a laboratory-scale reactor (124 data points), a package boiler (61 data points), and operating municipal waste incinerators (114 data points). Regardless of the three scales and types of equipment, the different temperature profiles, sampling emissions and/or solids (fly ash), and the various chemical and physical properties of the fuels, all the PCDF plots showed highly linear correlations (R(2)>0.99). The fitting lines of the reactor and the boiler data were almost linear with slope of unity, whereas the slope of the municipal waste incinerator data was 0.86, which is caused by higher predicted values for samples with high measured TEQ. The strong correlation also implies that each of the 10 toxic PCDF congeners has a constant concentration relative to its respective total homologue concentration despite a wide range of facility types and combustion conditions. The PCDD plots showed significant scatter and poor linearity, which implies that the relative concentration of PCDD TEQ congeners is more sensitive to variations in reaction conditions than that of the PCDF congeners.

  8. Glucose Disappearance in Biological Treatment Systems

    PubMed Central

    Jeris, John S.; Cardenas, Raul R.

    1966-01-01

    Laboratory scale anaerobic and aerobic treatment units were conditioned with a daily slug-feed of glucose. After a period of acclimation and stabilization, glucose disappearance was monitored continuously after the slug feed. A continuous sampling apparatus is described. Mathematical analysis of the data indicate zero-order reactions for both biological treatment systems. PMID:16349685

  9. Investigation of the tone-burst tube for duct lining attenuation measurement

    NASA Technical Reports Server (NTRS)

    Soffel, A. R.; Morrow, P. F.

    1972-01-01

    The tone burst technique makes practical the laboratory evaluation of potential inlet and discharge duct treatments. Tone burst apparatus requires only simple machined parts and standard components. Small, simply made, lining samples are quickly and easily installed in the system. Two small electromagnetric loudspeaker drivers produce peak sound pressure level of over 166 db in the 3-square-inch sample duct. Air pump available in most laboratories can produce air flows of over plus and minus Mach 0.3 in the sample duct. The technique uses short shaped pulses of sound propagated down a progressive wave tube containing the sample duct. The peak pressure level output of the treated duct is compared with the peak pressure level output of a substituted reference duct. The difference between the levels is the attenuation or insertion loss of the treated duct. Evaluations of resonant absorber linings by the tone burst technique check attenuation values predicted by empirical formulas based on full scale ducts.

  10. Development of a molecular method for testing the effectiveness of UV systems on-site.

    PubMed

    Nizri, Limor; Vaizel-Ohayon, Dalit; Ben-Amram, Hila; Sharaby, Yehonatan; Halpern, Malka; Mamane, Hadas

    2017-12-15

    We established a molecular method for quantifying ultraviolet (UV) disinfection efficacy using total bacterial DNA in a water sample. To evaluate UV damage to the DNA, we developed the "DNA damage" factor, which is a novel cultivation-independent approach that reveals UV-exposure efficiency by applying a simple PCR amplification method. The study's goal was to prove the feasibility of this method for demonstrating the efficiency of UV systems in the field using flow-through UV reactors. In laboratory-based experiments using seeded bacteria, the DNA damage tests demonstrated a good correlation between PCR products and UV dose. In the field, natural groundwater sampled before and after being subjected to the full-scale UV reactors was filtered, and the DNA extracted from the filtrate was subjected to PCR amplification for a 900-bp fragment of the 16S rRNA gene with initial DNA concentrations of 0.1 and 1 ng/μL. In both cases, the UV dose predicted and explained a significant proportion of the variance in the log inactivation ratio and DNA damage factor. Log inactivation ratio was very low, as expected in groundwater due to low initial bacterial counts, whereas the DNA damage factor was within the range of values obtained in the laboratory-based experiments. Consequently, the DNA damage factor reflected the true performance of the full-scale UV system during operational water flow by using the indigenous bacterial array present in a water sample. By applying this method, we were able to predict with high confidence, the UV reactor inactivation potential. For method validation, laboratory and field iterations are required to create a practical field calibration curve that can be used to determine the expected efficiency of the full-scale UV system in the field under actual operation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Prediction of SOC content by Vis-NIR spectroscopy at European scale using a modified local PLS algorithm

    NASA Astrophysics Data System (ADS)

    Nocita, M.; Stevens, A.; Toth, G.; van Wesemael, B.; Montanarella, L.

    2012-12-01

    In the context of global environmental change, the estimation of carbon fluxes between soils and the atmosphere has been the object of a growing number of studies. This has been motivated notably by the possibility to sequester CO2 into soils by increasing the soil organic carbon (SOC) stocks and by the role of SOC in maintaining soil quality. Spatial variability of SOC masks its slow accumulation or depletion, and the sampling density required to detect a change in SOC content is often very high and thus very expensive and labour intensive. Visible near infrared diffuse reflectance spectroscopy (Vis-NIR DRS) has been shown to be a fast, cheap and efficient tool for the prediction of SOC at fine scales. However, when applied to regional or country scales, Vis-NIR DRS did not provide sufficient accuracy as an alternative to standard laboratory soil analysis for SOC monitoring. Under the framework of Land Use/Cover Area Frame Statistical Survey (LUCAS) project of the European Commission's Joint Research Centre (JRC), about 20,000 samples were collected all over European Union. Soil samples were analyzed for several physical and chemical parameters, and scanned with a Vis-NIR spectrometer in the same laboratory. The scope of our research was to predict SOC content at European scale using LUCAS spectral library. We implemented a modified local partial least square regression (l-PLS) including, in addition to spectral distance, other potentially useful covariates (geography, texture, etc.) to select for each unknown sample a group of predicting neighbours. The dataset was split in mineral soils under cropland, mineral soils under grassland, mineral soils under woodland, and organic soils due to the extremely diverse spectral response of the four classes. Four every class training (70%) and test (30%) sets were created to calibrate and validate the SOC prediction models. The results showed very good prediction ability for mineral soils under cropland and mineral soils under grassland, with a root mean square error (RMSE) of 3.6 and 7.2 g C kg-1 respectively, while mineral soils under woodland and organic soils predictions were less accurate (RMSE of 11.9 and 51.1 g C kg-1). The RMSE was lower (except for organic soils) when sand content was used as covariate in the selection of the l-PLS predicting neighbours. The obtained results proved that: (i) Although the enormous spatial variability of European soils, the developed modified l-PLS algorithm was able to produce stable calibrations and accurate predictions. (ii) It is essential to invest in spectral libraries built according to sampling strategies, based on soil types, and a standardized laboratory protocol. (iii) Vis-NIR DRS spectroscopy is a powerful and cost effective tool to predict SOC content at regional/continental scales, and should be converted from a pure research discipline into a reference operational method decreasing the uncertainties of SOC monitoring and terrestrial ecosystems carbon fluxes at all scales.

  12. Competition between Naegleria fowleri and Free Living Amoeba Colonizing Laboratory Scale and Operational Drinking Water Distribution Systems.

    PubMed

    Miller, Haylea C; Wylie, Jason T; Kaksonen, Anna H; Sutton, David; Puzon, Geoffrey J

    2018-03-06

    Free living amoebae (FLA), including pathogenic Naegleria fowleri, can colonize and grow within pipe wall biofilms of drinking water distribution systems (DWDSs). Studies on the interactions between various FLA species in biofilms are limited. Understanding the interaction between FLA and the broader biofilm ecology could help better predict DWDS susceptibility to N. fowleri colonization. The aim of this study was to determine if N. fowleri and other FLAs ( Naegleria, Vermamoeba, Willaertia, and Vahlkampfia spp.) cocolonize DWDS biofilm. FLAs commonly isolated from DWDSs ( N. fowleri, V. vermiformis, and N. lovaniensis) were introduced into laboratory-scale biomonitors to determine the impact of these amoebae on N. fowleri's presence and viability. Over 18 months, a single viable amoebae ( N. fowleri, N. lovaniensis, or V. vermiformis) was detected in each biofilm sample, with the exception of N. lovaniensis and N. fowleri, which briefly cocolonized biofilm following their coinoculation. The analysis of biofilm and bulk water samples from operational DWDSs revealed a similar lack of cocolonization with a single FLA detected in 99% ( n = 242) of samples. Interestingly, various Naegleria spp. did colonize the same DWDS locations but at different times. This knowledge furthers the understanding of ecological factors which enable N. fowleri to colonize and survive within operational DWDSs and could aid water utilities to control its occurrence.

  13. The influence of testing apparatus stiffness on the source properties of laboratory stick-slip

    NASA Astrophysics Data System (ADS)

    Kilgore, B. D.; McGarr, A.; Beeler, N. M.; Lockner, D. A.

    2016-12-01

    Stick-slip experiments were performed to determine the influence of the testing apparatus stiffness on source properties, to develop methods to relate stick-slip to natural earthquakes, and to examine the hypothesis of McGarr [2012] that the product of unloading stiffness, k, and slip duration, T, is both scale-independent and approximately constant for both laboratory and natural earthquakes. A double-direct shear load frame was used with Sierra White Granite samples at 2 MPa normal stress, and a remote loading rate of 0.2 µm/s. The stiffness of the test apparatus was varied by more than an order of magnitude by inserting disk springs into the shear loading column adjacent to the granite samples. Servo-controlling slip at a point between the forcing ram and the shear force load cell, produced repeatable slip events. Slip and slip duration decrease as k increases, as they do for natural earthquakes. In contrast to earthquakes, stress drop and slip rate decrease with increasing k, and the product kT for these experiments is not constant, but decreases with k. These data, collected over a range of k, do not conform to McGarr's [2012] hypothesis. However, analysis of stick-slip studies from other testing apparatuses is consistent with McGarr's hypothesis; kT is scale-independent, similar to that of earthquakes, equal to the ratio of static stress drop to average slip velocity, and similar to the ratio of shear modulus to wavespeed of rock. These properties result from conducting experiments over a range of sample sizes, using rock samples with the same elastic properties as the Earth, and using testing machines whose stiffnesses decrease, and characteristic periods increase with scale. A consequence of our experiments and analysis is that extrapolation of lab scale earthquake source properties to the Earth is more difficult than previously thought, requiring an accounting for the properties of the testing machines and additional research beyond that reported here.

  14. Integrated Data Collection Analysis (IDCA) Program - RDX Type II Class 5 Standard, Data Set 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.

    This document describes the results of the first reference sample material—RDX Type II Class 5—examined in the proficiency study for small-scale safety and thermal (SSST) testing of explosive materials for the Integrated Data Collection Analysis (IDCA) Program. The IDCA program is conducting proficiency testing on homemade explosives (HMEs). The reference sample materials are being studied to establish the accuracy of traditional explosives safety testing for each performing laboratory. These results will be used for comparison to results from testing HMEs. This effort, funded by the Department of Homeland Security (DHS), ultimately will put the issues of safe handling of thesemore » materials in perspective with standard military explosives. The results of the study will add SSST testing results for a broad suite of different HMEs to the literature, potentially suggest new guidelines and methods for HME testing, and possibly establish what are the needed accuracies in SSST testing to develop safe handling practices. Described here are the results for impact, friction, electrostatic discharge, and scanning calorimetry analysis of a reference sample of RDX Type II Class 5. The results from each participating testing laboratory are compared using identical test material and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. These results are then compared to historical data from various sources. The performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Air Force Research Laboratory/ RXQL (AFRL), Indian Head Division, Naval Surface Warfare Center, (IHD-NSWC), and Sandia National Laboratories (SNL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to understand how to compare results when test protocols are not identical.« less

  15. [Development of a laboratory test on dried blood spots for facilitating early diagnosis of alpha-1-antitrypsin deficiency].

    PubMed

    Balduyck, Malika; Chapuis Cellier, Colette; Roche, Denis; Odou, Marie-Françoise; Joly, Philippe; Madelain, Vincent; Vergne, Anita; Nouadje, Georges; Lafitte, Jean-Jacques; Porchet, Nicole; Beaune, Philippe; Zerimech, Farid

    2014-01-01

    Alpha- 1-antitrypsin (A1AT) deficiency is a hereditary autosomal codominant genetic disorder resulting in low circulating levels of A1AT and leading to lung and/or liver disease. It remains underdiagnosed and only 5 to 10% of PIZZ patients, the most common form of severe A1AT deficiency, would be actually identified in France. Facilitating early diagnosis of A1AT deficiency would allow a better management of this disease; therefore we have developed and standardized in three laboratories involved in this study, a diagnostic test on dried blood spots (DBS) including quantitative A1AT measurement, phenotyping by IEF electrophoresis and, if necessary, genotyping by SERPINA1 gene sequencing. We performed a quantitative assay on 90 DBS samples by immunoturbidimetric or immunonephelometric methods. We demonstrated that both methods were suitable for this type of sampling and the results obtained were highly correlated (R(2)>0.9) between the three laboratories: for a target value of 1.00 g/L, the results obtained from the three laboratories were between 1.00 and 1.02 g/L. Phenotyping and genotyping were performed under redefined operating conditions and adapted to the analysis of DBS samples. The results were comparable with those obtained for venous blood samples. Following this work, it becomes possible to provide pulmonologists with a reliable kit to perform a capillary blood sampling on filter paper which would allow a large-scale screening of A1AT deficiency in the population particularly affected by this genetic condition.

  16. Request Pattern, Pre-Analytical and Analytical Conditions of Urinalysis in Primary Care: Lessons from a One-Year Large-Scale Multicenter Study.

    PubMed

    Salinas, Maria; Lopez-Garrigos, Maite; Flores, Emilio; Leiva-Salinas, Carlos

    2018-06-01

    To study the urinalysis request, pre-analytical sample conditions, and analytical procedures. Laboratories were asked to provide the number of primary care urinalyses requested, and to fill out a questionnaire regarding pre-analytical conditions and analytical procedures. 110 laboratories participated in the study. 232.5 urinalyses/1,000 inhabitants were reported. 75.4% used the first morning urine. The sample reached the laboratory in less than 2 hours in 18.8%, between 2 - 4 hours in 78.3%, and between 4 - 6 hours in the remaining 2.9%. 92.5% combined the use of test strip and particle analysis, and only 7.5% used the strip exclusively. All participants except one performed automated particle analysis depending on strip results; in 16.2% the procedure was only manual. Urinalysis was highly requested. There was a lack of compliance with guidelines regarding time between micturition and analysis that usually involved the combination of strip followed by particle analysis.

  17. Cyclic formation and dissociation of methane hydrate within partially water saturated sand

    NASA Astrophysics Data System (ADS)

    Kneafsey, T. J.; Nakagawa, S.

    2010-12-01

    For partially water-saturated sediments, laboratory experiments have shown that methane hydrate forms heterogeneously within a sample at the core scale. The heterogeneous distribution of hydrate in combination with grain-scale hydrate location (eg. grain cementing, load bearing, and pore filling), determines the overall mechanical properties of hydrate-bearing sediments including shear strength and seismic properties. For this reason, understanding the heterogeneity of hydrate-bearing sample is essential when the bulk properties of the sample are examined in the laboratory. We present a series of laboratory methane hydrate formation and dissociation experiments with concurrent x-ray CT imaging and low-frequency (near 1 kHz) seismic measurements. The seismic measurements were conducted using a new acoustic resonant bar technique called the Split Hopkinson Resonant Bar method, which allows using a small sediment core (3.75 cm diameter, 7.5 cm length). The experiment was conducted using a jacketed, pre-compacted, fine-grain silica sand sample with a 40% distilled water saturation. Under isotropic confining stress of 6.9 MPa and a temperature 4 oC, the hydrate was formed in the sample by injecting pure methane gas at 5.6 MPa. Once the hydrate formed, it was dissociated by reducing the pore pressure to 2.8 MPa. This cycle was repeated by three times (dissociation test for the third cycle was not done) to examine the resulting changes in the hydrate distribution and seismic signatures. The repeated formation of hydrate resulted in significant changes in its distribution, which resulted in differences in the overall elastic properties of the sample, determined from the seismic measurements. Interestingly, the time intervals between the dissociation and subsequent formation of hydrate affected the rate of hydrate formation, shorter intervals resulting in faster formation. This memory effect, possibly caused by the presence of residual “seed crystals” in the pore water providing nucleation points for hydrate formation, did not result in rapid formation at all locations in the sample. In spite of heterogeneity, observed seismic properties were very similar for the two measurements during dissociation.

  18. Cost-effective sampling of ¹³⁷Cs-derived net soil redistribution: part 1--estimating the spatial mean across scales of variation.

    PubMed

    Li, Y; Chappell, A; Nyamdavaa, B; Yu, H; Davaasuren, D; Zoljargal, K

    2015-03-01

    The (137)Cs technique for estimating net time-integrated soil redistribution is valuable for understanding the factors controlling soil redistribution by all processes. The literature on this technique is dominated by studies of individual fields and describes its typically time-consuming nature. We contend that the community making these studies has inappropriately assumed that many (137)Cs measurements are required and hence estimates of net soil redistribution can only be made at the field scale. Here, we support future studies of (137)Cs-derived net soil redistribution to apply their often limited resources across scales of variation (field, catchment, region etc.) without compromising the quality of the estimates at any scale. We describe a hybrid, design-based and model-based, stratified random sampling design with composites to estimate the sampling variance and a cost model for fieldwork and laboratory measurements. Geostatistical mapping of net (1954-2012) soil redistribution as a case study on the Chinese Loess Plateau is compared with estimates for several other sampling designs popular in the literature. We demonstrate the cost-effectiveness of the hybrid design for spatial estimation of net soil redistribution. To demonstrate the limitations of current sampling approaches to cut across scales of variation, we extrapolate our estimate of net soil redistribution across the region, show that for the same resources, estimates from many fields could have been provided and would elucidate the cause of differences within and between regional estimates. We recommend that future studies evaluate carefully the sampling design to consider the opportunity to investigate (137)Cs-derived net soil redistribution across scales of variation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. LUNAR SAMPLES - APOLLO XI - MSC

    NASA Image and Video Library

    1969-07-28

    S69-45009 (27 July 1969) --- This is the first lunar sample that was photographed in detail in the Lunar Receiving Laboratory (LRL) at the Manned Spacecraft Center (MSC). The photograph shows a granular, fine-grained, mafic (iron magnesium rich) rock. At this early stage of the examination, this rock appears similar to several igneous rock types found on Earth. The scale is printed backwards due to the photographic configuration in the Vacuum Chamber. The sample number is 10003. This rock was among the samples collected by astronauts Neil A. Armstrong and Edwin E. Aldrin Jr. during their lunar surface extravehicular activity (EVA) on July 20, 1969.

  20. Understanding safety data sheets as a strategy to protect humans and the environment at the laboratory

    NASA Astrophysics Data System (ADS)

    Elza, Rizkiawalia; Suherman, Suherman

    2018-02-01

    Safety Data Sheet (SDS) gave important information for safe chemicals handling and widely used in communicating chemical hazards. Laboratory as one of the places associated with the consumption of a number of chemicals, then the worker in laboratory have to know the information chemicals used. The purpose of this research is to know the perception and understanding of workers in a laboratory toward SDS. The quantitative research was used and the collect data by questionnaire using Likert scale, then analyzed descriptively. The total sample of data was twenty-seven of laboratory worker people. The finding from this study showed that a great majority of people agree SDS has benefits for workers in the laboratory, agree the SDS should be available in the workplace, feel the need to know the contents of the SDS, but not so many people agree `I access SDS while working using chemicals' and great majority of people feel `I obtained chemical information other than SDS'.

  1. PASSIM--an open source software system for managing information in biomedical studies.

    PubMed

    Viksna, Juris; Celms, Edgars; Opmanis, Martins; Podnieks, Karlis; Rucevskis, Peteris; Zarins, Andris; Barrett, Amy; Neogi, Sudeshna Guha; Krestyaninova, Maria; McCarthy, Mark I; Brazma, Alvis; Sarkans, Ugis

    2007-02-09

    One of the crucial aspects of day-to-day laboratory information management is collection, storage and retrieval of information about research subjects and biomedical samples. An efficient link between sample data and experiment results is absolutely imperative for a successful outcome of a biomedical study. Currently available software solutions are largely limited to large-scale, expensive commercial Laboratory Information Management Systems (LIMS). Acquiring such LIMS indeed can bring laboratory information management to a higher level, but often implies sufficient investment of time, effort and funds, which are not always available. There is a clear need for lightweight open source systems for patient and sample information management. We present a web-based tool for submission, management and retrieval of sample and research subject data. The system secures confidentiality by separating anonymized sample information from individuals' records. It is simple and generic, and can be customised for various biomedical studies. Information can be both entered and accessed using the same web interface. User groups and their privileges can be defined. The system is open-source and is supplied with an on-line tutorial and necessary documentation. It has proven to be successful in a large international collaborative project. The presented system closes the gap between the need and the availability of lightweight software solutions for managing information in biomedical studies involving human research subjects.

  2. LIMS for Lasers 2015 for achieving long-term accuracy and precision of δ2H, δ17O, and δ18O of waters using laser absorption spectrometry

    USGS Publications Warehouse

    Coplen, Tyler B.; Wassenaar, Leonard I

    2015-01-01

    RationaleAlthough laser absorption spectrometry (LAS) instrumentation is easy to use, its incorporation into laboratory operations is not easy, owing to extensive offline manipulation of comma-separated-values files for outlier detection, between-sample memory correction, nonlinearity (δ-variation with water amount) correction, drift correction, normalization to VSMOW-SLAP scales, and difficulty in performing long-term QA/QC audits.MethodsA Microsoft Access relational-database application, LIMS (Laboratory Information Management System) for Lasers 2015, was developed. It automates LAS data corrections and manages clients, projects, samples, instrument-sample lists, and triple-isotope (δ17O, δ18O, and δ2H values) instrumental data for liquid-water samples. It enables users to (1) graphically evaluate sample injections for variable water yields and high isotope-delta variance; (2) correct for between-sample carryover, instrumental drift, and δ nonlinearity; and (3) normalize final results to VSMOW-SLAP scales.ResultsCost-free LIMS for Lasers 2015 enables users to obtain improved δ17O, δ18O, and δ2H values with liquid-water LAS instruments, even those with under-performing syringes. For example, LAS δ2HVSMOW measurements of USGS50 Lake Kyoga (Uganda) water using an under-performing syringe having ±10 % variation in water concentration gave +31.7 ± 1.6 ‰ (2-σ standard deviation), compared with the reference value of +32.8 ± 0.4 ‰, after correction for variation in δ value with water concentration, between-sample memory, and normalization to the VSMOW-SLAP scale.ConclusionsLIMS for Lasers 2015 enables users to create systematic, well-founded instrument templates, import δ2H, δ17O, and δ18O results, evaluate performance with automatic graphical plots, correct for δ nonlinearity due to variable water concentration, correct for between-sample memory, adjust for drift, perform VSMOW-SLAP normalization, and perform long-term QA/QC audits easily. Published in 2015. This article is a U.S. Government work and is in the public domain in the USA.

  3. Measurement of the total activity concentrations of Libyan oil scale

    NASA Astrophysics Data System (ADS)

    Da Silva, F. C. A.; Bradley, D. A.; Regan, P. H.; Rozaila, Z. Siti

    2017-08-01

    Twenty-three oil scale samples obtained from the Libyan oil and gas industry production facilities onshore have been measured using high-resolution gamma-ray spectrometry with a shielded HPGe detector, the work being carried out within the Environmental Radioactivity Laboratory at the University of Surrey. The main objectives of this work were to determine the extent to which the predominant radionuclides associated with the uranium and thorium natural decay chains were in secular equilibrium with their decay progeny, also to compare differences between the total activity concentrations (TAC) in secular equilibrium and disequilibrium and to evaluate the measured activities for the predominant gamma-ray emitting decay radionuclides within the 232Th and 238U chains. The oil scale NORM samples did not exhibit radioactive equilibrium between the decay progeny and longer-lived parent radionuclides of the 238U and 232Th series.

  4. Quarterly Research Performance Progress Report (2015 Q3). Ultrasonic Phased Arrays and Interactive Reflectivity Tomography for Nondestructive Inspection of Injection and Production Wells in Geothermal Energy Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Santos-Villalobos, Hector J; Polsky, Yarom; Kisner, Roger A

    2015-09-01

    For the past quarter, we have placed our effort in implementing the first version of the ModelBased Iterative Reconstruction (MBIR) algorithm, assembling and testing the electronics, designing transducers mounts, and defining our laboratory test samples. We have successfully developed the first implementation of MBIR for ultrasound imaging. The current algorithm was tested with synthetic data and we are currently making new modifications for the reconstruction of real ultrasound data. Beside assembling and testing the electronics, we developed a LabView graphic user interface (GUI) to fully control the ultrasonic phased array, adjust the time-delays of the transducers, and store the measuredmore » reflections. As part of preparing for a laboratory-scale demonstration, the design and fabrication of the laboratory samples has begun. Three cement blocks with embedded objects will be fabricated, characterized, and used to demonstrate the capabilities of the system. During the next quarter, we will continue to improve the current MBIR forward model and integrate the reconstruction code with the LabView GUI. In addition, we will define focal laws for the ultrasonic phased array and perform the laboratory demonstration. We expect to perform laboratory demonstration by the end of October 2015.« less

  5. Large-Scale Optimization for Bayesian Inference in Complex Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willcox, Karen; Marzouk, Youssef

    2013-11-12

    The SAGUARO (Scalable Algorithms for Groundwater Uncertainty Analysis and Robust Optimization) Project focused on the development of scalable numerical algorithms for large-scale Bayesian inversion in complex systems that capitalize on advances in large-scale simulation-based optimization and inversion methods. The project was a collaborative effort among MIT, the University of Texas at Austin, Georgia Institute of Technology, and Sandia National Laboratories. The research was directed in three complementary areas: efficient approximations of the Hessian operator, reductions in complexity of forward simulations via stochastic spectral approximations and model reduction, and employing large-scale optimization concepts to accelerate sampling. The MIT--Sandia component of themore » SAGUARO Project addressed the intractability of conventional sampling methods for large-scale statistical inverse problems by devising reduced-order models that are faithful to the full-order model over a wide range of parameter values; sampling then employs the reduced model rather than the full model, resulting in very large computational savings. Results indicate little effect on the computed posterior distribution. On the other hand, in the Texas--Georgia Tech component of the project, we retain the full-order model, but exploit inverse problem structure (adjoint-based gradients and partial Hessian information of the parameter-to-observation map) to implicitly extract lower dimensional information on the posterior distribution; this greatly speeds up sampling methods, so that fewer sampling points are needed. We can think of these two approaches as ``reduce then sample'' and ``sample then reduce.'' In fact, these two approaches are complementary, and can be used in conjunction with each other. Moreover, they both exploit deterministic inverse problem structure, in the form of adjoint-based gradient and Hessian information of the underlying parameter-to-observation map, to achieve their speedups.« less

  6. Medical Products Research

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Ventrex Laboratories, Inc. develops, manufactures and markets a line of medical diagnostic assays based on biochemical techniques, in particular immunochemical techniques. Their products are sold worldwide to hospitals and medical laboratories for use in testing blood samples and other biological fluids. Analysis of a patient's body fluids, compared with normal values, aids a physician in confirming or otherwise diagnosing a suspected disease condition. NERAC's rapid information retrieval has provided Ventrex invaluable up-to-date information, and has permitted large scale savings. NERAC's service was particularly important in the development of a new product in the company's Ventre/Sep line, which is used in radioimmunoassays.

  7. The Relationships between University Students' Chemistry Laboratory Anxiety, Attitudes, and Self-Efficacy Beliefs

    ERIC Educational Resources Information Center

    Kurbanoglu, N. Izzet; Akin, Ahmet

    2010-01-01

    The aim of this study is to examine the relationships between chemistry laboratory anxiety, chemistry attitudes, and self-efficacy. Participants were 395 university students. Participants completed the Chemistry Laboratory Anxiety Scale, the Chemistry Attitudes Scale, and the Self-efficacy Scale. Results showed that chemistry laboratory anxiety…

  8. Numerical simulation on hydromechanical coupling in porous media adopting three-dimensional pore-scale model.

    PubMed

    Liu, Jianjun; Song, Rui; Cui, Mengmeng

    2014-01-01

    A novel approach of simulating hydromechanical coupling in pore-scale models of porous media is presented in this paper. Parameters of the sandstone samples, such as the stress-strain curve, Poisson's ratio, and permeability under different pore pressure and confining pressure, are tested in laboratory scale. The micro-CT scanner is employed to scan the samples for three-dimensional images, as input to construct the model. Accordingly, four physical models possessing the same pore and rock matrix characteristics as the natural sandstones are developed. Based on the micro-CT images, the three-dimensional finite element models of both rock matrix and pore space are established by MIMICS and ICEM software platform. Navier-Stokes equation and elastic constitutive equation are used as the mathematical model for simulation. A hydromechanical coupling analysis in pore-scale finite element model of porous media is simulated by ANSYS and CFX software. Hereby, permeability of sandstone samples under different pore pressure and confining pressure has been predicted. The simulation results agree well with the benchmark data. Through reproducing its stress state underground, the prediction accuracy of the porous rock permeability in pore-scale simulation is promoted. Consequently, the effects of pore pressure and confining pressure on permeability are revealed from the microscopic view.

  9. Numerical Simulation on Hydromechanical Coupling in Porous Media Adopting Three-Dimensional Pore-Scale Model

    PubMed Central

    Liu, Jianjun; Song, Rui; Cui, Mengmeng

    2014-01-01

    A novel approach of simulating hydromechanical coupling in pore-scale models of porous media is presented in this paper. Parameters of the sandstone samples, such as the stress-strain curve, Poisson's ratio, and permeability under different pore pressure and confining pressure, are tested in laboratory scale. The micro-CT scanner is employed to scan the samples for three-dimensional images, as input to construct the model. Accordingly, four physical models possessing the same pore and rock matrix characteristics as the natural sandstones are developed. Based on the micro-CT images, the three-dimensional finite element models of both rock matrix and pore space are established by MIMICS and ICEM software platform. Navier-Stokes equation and elastic constitutive equation are used as the mathematical model for simulation. A hydromechanical coupling analysis in pore-scale finite element model of porous media is simulated by ANSYS and CFX software. Hereby, permeability of sandstone samples under different pore pressure and confining pressure has been predicted. The simulation results agree well with the benchmark data. Through reproducing its stress state underground, the prediction accuracy of the porous rock permeability in pore-scale simulation is promoted. Consequently, the effects of pore pressure and confining pressure on permeability are revealed from the microscopic view. PMID:24955384

  10. Scaling of coupled dilatancy-diffusion processes in space and time

    NASA Astrophysics Data System (ADS)

    Main, I. G.; Bell, A. F.; Meredith, P. G.; Brantut, N.; Heap, M.

    2012-04-01

    Coupled dilatancy-diffusion processes resulting from microscopically brittle damage due to precursory cracking have been observed in the laboratory and suggested as a mechanism for earthquake precursors. One reason precursors have proven elusive may be the scaling in space: recent geodetic and seismic data placing strong limits on the spatial extent of the nucleation zone for recent earthquakes. Another may be the scaling in time: recent laboratory results on axi-symmetric samples show both a systematic decrease in circumferential extensional strain at failure and a delayed and a sharper acceleration of acoustic emission event rate as strain rate is decreased. Here we examine the scaling of such processes in time from laboratory to field conditions using brittle creep (constant stress loading) to failure tests, in an attempt to bridge part of the strain rate gap to natural conditions, and discuss the implications for forecasting the failure time. Dilatancy rate is strongly correlated to strain rate, and decreases to zero in the steady-rate creep phase at strain rates around 10-9 s-1 for a basalt from Mount Etna. The data are well described by a creep model based on the linear superposition of transient (decelerating) and accelerating micro-crack growth due to stress corrosion. The model produces good fits to the failure time in retrospect using the accelerating acoustic emission event rate, but in prospective tests on synthetic data with the same properties we find failure-time forecasting is subject to systematic epistemic and aleatory uncertainties that degrade predictability. The next stage is to use the technology developed to attempt failure forecasting in real time, using live streamed data and a public web-based portal to quantify the prospective forecast quality under such controlled laboratory conditions.

  11. Control of occupational exposure to phenol in industrial wastewater treatment plant of a petroleum refinery in Alexandria, Egypt: An intervention application case study.

    PubMed

    Zaki, Gehan R; El-Marakby, Fadia A; Ramadan, Alaa El-Din K; Issa, Ahmed I; Nofal, Faten H

    2016-11-01

    Phenol exposure is one of the hazards in the industrial wastewater treatment basin of any refinery. It additively interacts with hydrogen sulfide emitted from the wastewater basin. Consequently, its concentration should be greatly lower than its threshold limit value. The present study aimed at controlling occupational exposure to phenol in the work environment of wastewater treatment plant in a refinery by reducing phenolic compounds in the industrial wastewater basin. This study was conducted on both laboratory and refinery scales. The first was completed by dividing each wastewater sample from the outlets of different refinery units into three portions; the first was analyzed for phenolic compounds. The second and third were for laboratory scale charcoal and bacterial treatments. The two methods were compared regarding their simplicities, design, and removal efficiencies. Accordingly, bacterial treatment by continuous flow of sewage water containing Pseudomonas Aeruginosa was used for refinery scale treatment. Laboratory scale treatment of phenolic compounds revealed higher removal efficiency of charcoal [100.0(0.0) %] than of bacteria [99.9(0.013) %]. The refinery scale bacterial treatment was [99.8(0.013) %] efficient. Consequently, level of phenol in the work environment after refinery-scale treatment [0.069(0.802) mg/m(3)] was much lower than that before [5.700(26.050) mg/m(3)], with removal efficiency of [99.125(2.335) %]. From the present study, we can conclude that bacterial treatment of phenolic compounds in industrial wastewater of the wastewater treatment plant using continuous flow of sewage water containing Pseudomonas Aeruginosa reduces the workers' exposure to phenol.

  12. Department of Homeland Security (DHS) Proficiency Testing on Small-Scale Safety and Thermal Testing of Improvised Explosives

    NASA Astrophysics Data System (ADS)

    Reynolds, John; Sandstrom, Mary; Brown, Geoffrey; Warner, Kirstin; Phillips, Jason; Shelley, Timothy; Reyes, Jose; Hsu, Peter

    2013-06-01

    One of the first steps in establishing safe handling procedures for explosives is small-scale safety and thermal (SSST) testing. To better understand the response of improvised materials or HMEs to SSST testing, 18 HME materials were compared to 3 standard military explosives in a proficiency-type round robin study among five laboratories--2 DoD and 3 DOE--sponsored by DHS. The testing matrix has been designed to address problems encountered with improvised materials--powder mixtures, liquid suspensions, partially wetted solids, immiscible liquids, and reactive materials. Over 30 issues have been identified that indicate standard test methods may require modification when applied to HMEs to derive accurate sensitivity assessments needed for development safe handling and storage practices. This presentation will discuss experimental difficulties encountered when testing these problematic samples, show inter-laboratory testing results, show some statistical interpretation of the results, and highlight some of the testing issues. Some of the work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344. LLNL-ABS-617519 (721812).

  13. A Comparison of Laboratory and Clinical Working Memory Tests and Their Prediction of Fluid Intelligence

    PubMed Central

    Shelton, Jill T.; Elliott, Emily M.; Hill, B. D.; Calamia, Matthew R.; Gouvier, Wm. Drew

    2010-01-01

    The working memory (WM) construct is conceptualized similarly across domains of psychology, yet the methods used to measure WM function vary widely. The present study examined the relationship between WM measures used in the laboratory and those used in applied settings. A large sample of undergraduates completed three laboratory-based WM measures (operation span, listening span, and n-back), as well as the WM subtests from the Wechsler Adult Intelligence Scale-III and the Wechsler Memory Scale-III. Performance on all of the WM subtests of the clinical batteries shared positive correlations with the lab measures; however, the Arithmetic and Spatial Span subtests shared lower correlations than the other WM tests. Factor analyses revealed that a factor comprising scores from the three lab WM measures and the clinical subtest, Letter-Number Sequencing (LNS), provided the best measurement of WM. Additionally, a latent variable approach was taken using fluid intelligence as a criterion construct to further discriminate between the WM tests. The results revealed that the lab measures, along with the LNS task, were the best predictors of fluid abilities. PMID:20161647

  14. Fluid Pressure Variation in a Sedimentary Geothermal Reservoir in the North German Basin: Case Study Groß Schönebeck

    NASA Astrophysics Data System (ADS)

    Huenges, Ernst; Trautwein, Ute; Legarth, Björn; Zimmermann, Günter

    2006-10-01

    The Rotliegend of the North German basin is the target reservoir of an interdisciplinary investigation program to develop a technology for the generation of geothermal electricity from low-enthalpy reservoirs. An in situ downhole laboratory was established in the 4.3 km deep well Groβ Schönebeck with the purpose of developing appropriate stimulation methods to increase permeability of deep aquifers by enhancing or creating secondary porosity and flow paths. The goal is to learn how to enhance the inflow performance of a well from a variety of rock types in low permeable geothermal reservoirs. A change in effective stress due to fluid pressure was observed to be one of the key parameters influencing flow properties both downhole and in laboratory experiments on reservoir rocks. Fluid pressure variation was induced using proppant-gel-frac techniques as well as waterfrac techniques in several different new experiments in the borehole. A pressure step test indicates generation and extension of multiple fractures with closure pressures between 6 and 8.4 MPa above formation pressure. In a 24-hour production test 859 m3 water was produced from depth indicating an increase of productivity in comparison with former tests. Different depth sections and transmissibility values were observed in the borehole depending on fluid pressure. In addition, laboratory experiments were performed on core samples from the sandstone reservoir under uniaxial strain conditions, i.e., no lateral strain, constant axial load. The experiments on the borehole and the laboratory scale were realized on the same rock types under comparable stress conditions with similar pore pressure variations. Nevertheless, stress dependences of permeability are not easy to compare from scale to scale. Laboratory investigations reflect permeability variations due to microstructural heterogeneities and the behavior in the borehole is dominated by the generation of connections to large-scale structural patterns.

  15. The micron- to kilometer-scale Moon: linking samples to orbital observations, Apollo to LRO

    NASA Astrophysics Data System (ADS)

    Crites, S.; Lucey, P. G.; Taylor, J.; Martel, L.; Sun, L.; Honniball, C.; Lemelin, M.

    2017-12-01

    The Apollo missions have shaped the field of lunar science and our understanding of the Moon, from global-scale revelations like the magma ocean hypothesis, to providing ground truth for compositional remote sensing and absolute ages to anchor cratering chronologies. While lunar meteorite samples can provide a global- to regional-level view of the Moon, samples returned from known locations are needed to directly link orbital-scale observations with laboratory measurements-a link that can be brought to full fruition with today's extremely high spatial resolution observations from Lunar Reconnaissance Orbiter and other recent missions. Korotev et al. (2005) described a scenario of the Moon without Apollo to speculate about our understanding of the Moon if our data were confined to lunar meteorites and remote sensing. I will review some of the major points discussed by Korotev et al. (2005), and focus on some of the ways in which spectroscopic remote sensing in particular has benefited from the Apollo samples. For example, could the causes and effects of lunar-style space weathering have been unraveled without the Apollo samples? What would be the limitations on remote sensing compositional measurements that rely on Apollo samples for calibration and validation? And what new opportunities to bring together orbital and sample analyses now exist, in light of today's high spatial and spectral resolution remote sensing datasets?

  16. Triangle area water supply monitoring project, October 1988 through September 2001, North Carolina -- description of the water-quality network, sampling and analysis methods, and quality-assurance practices

    USGS Publications Warehouse

    Oblinger, Carolyn J.

    2004-01-01

    The Triangle Area Water Supply Monitoring Project was initiated in October 1988 to provide long-term water-quality data for six area water-supply reservoirs and their tributaries. In addition, the project provides data that can be used to determine the effectiveness of large-scale changes in water-resource management practices, document differences in water quality among water-supply types (large multiuse reservoir, small reservoir, run-of-river), and tributary-loading and in-lake data for water-quality modeling of Falls and Jordan Lakes. By September 2001, the project had progressed in four phases and included as many as 34 sites (in 1991). Most sites were sampled and analyzed by the U.S. Geological Survey. Some sites were already a part of the North Carolina Division of Water Quality statewide ambient water-quality monitoring network and were sampled by the Division of Water Quality. The network has provided data on streamflow, physical properties, and concentrations of nutrients, major ions, metals, trace elements, chlorophyll, total organic carbon, suspended sediment, and selected synthetic organic compounds. Project quality-assurance activities include written procedures for sample collection, record management and archive, collection of field quality-control samples (blank samples and replicate samples), and monitoring the quality of field supplies. In addition to project quality-assurance activities, the quality of laboratory analyses was assessed through laboratory quality-assurance practices and an independent laboratory quality-control assessment provided by the U.S. Geological Survey Branch of Quality Systems through the Blind Inorganic Sample Project and the Organic Blind Sample Project.

  17. A simple microviscometric approach based on Brownian motion tracking.

    PubMed

    Hnyluchová, Zuzana; Bjalončíková, Petra; Karas, Pavel; Mravec, Filip; Halasová, Tereza; Pekař, Miloslav; Kubala, Lukáš; Víteček, Jan

    2015-02-01

    Viscosity-an integral property of a liquid-is traditionally determined by mechanical instruments. The most pronounced disadvantage of such an approach is the requirement of a large sample volume, which poses a serious obstacle, particularly in biology and biophysics when working with limited samples. Scaling down the required volume by means of microviscometry based on tracking the Brownian motion of particles can provide a reasonable alternative. In this paper, we report a simple microviscometric approach which can be conducted with common laboratory equipment. The core of this approach consists in a freely available standalone script to process particle trajectory data based on a Newtonian model. In our study, this setup allowed the sample to be scaled down to 10 μl. The utility of the approach was demonstrated using model solutions of glycerine, hyaluronate, and mouse blood plasma. Therefore, this microviscometric approach based on a newly developed freely available script can be suggested for determination of the viscosity of small biological samples (e.g., body fluids).

  18. Service Quality and Patient Satisfaction: An Exploratory Study of Pathology Laboratories in Jaipur.

    PubMed

    Agarwal, Anuradha; Singh, Maithili R P

    2016-01-01

    One of the most important parts of healthcare system is diagnostics. Nowadays, Indians have become more aware of their health, due to improved and better availability of health related information, increase in medical tourism, and expanding health insurance. The demand for better diagnostic facilities have increased with the increase in lifestyle related diseases, excesses use of chemicals in agriculture practices and change in food habits. It is expected that the Indian diagnostic market will grow from USD $5 billion in the year 2012 to USD $32 billion by the year 2020 with 20% CAGR (India Brand Equity Foundation 2015 ). Today patients have easy access of information regarding the health services and they have become more concerned about it as they look forward to receiving the maximum value for their money. To win the confidence of the patients and to maintain that trust, it is required to deliver the right services to the right person at the right time. The purpose of this study was to develop a scale to measure the service quality at pathology laboratory. A thorough review of literature revealed that there are studies related to healthcare service quality but there is no such established scale to measure service quality of pathology laboratory. Thus, the authors strived to develop a reliable and valid instrument to measure the patients' perception toward pathology laboratory service quality. For this exploratory study was conducted on the sample of 80 patients of the laboratories in Jaipur city. The reliability and factor structures were tested to purify the scale. The findings revealed 13 items, comprising of three dimensions of service quality: responsiveness, tangibility, and reliability.

  19. Decomposition and carbon storage of selected paper products in laboratory-scale landfills.

    PubMed

    Wang, Xiaoming; De la Cruz, Florentino B; Ximenes, Fabiano; Barlaz, Morton A

    2015-11-01

    The objective of this study was to measure the anaerobic biodegradation of different types of paper products in laboratory-scale landfill reactors. The study included (a) measurement of the loss of cellulose, hemicellulose, organic carbon, and (b) measurement of the methane yields for each paper product. The test materials included two samples each of newsprint (NP), copy paper (CP), and magazine paper (MG), and one sample of diaper (DP). The methane yields, carbon storage factors and the extent of cellulose and hemicellulose decomposition all consistently show that papers made from mechanical pulps (e.g., NPs) are less degradable than those made from chemical pulps where essentially all lignin was chemically removed (e.g., CPs). The diaper, which is not only made from chemical pulp but also contains some gel and plastic, exhibited limited biodegradability. The extent of biogenic carbon conversion varied from 21 to 96% among papers, which contrasts with the uniform assumption of 50% by the Intergovernmental Panel on Climate Change (IPCC) for all degradable materials discarded in landfills. Biochemical methane potential tests also showed that the solids to liquid ratio used in the test can influence the results. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Mixing in a stratified shear flow: Energetics and sampling

    NASA Technical Reports Server (NTRS)

    Ivey, G. N.; Koseff, J. R.; Briggs, D. A.; Ferziger, J. H.

    1993-01-01

    Direct numerical simulations of the time evolution of homogeneous stably stratified shear flows have been performed for Richardson numbers from 0 to 1 and for Prandtl numbers between 0.1 and 2. The results indicate that mixing efficiency R(sub f) varies with turbulent Froude number in a manner consistent with laboratory experiments performed with Prandtl numbers of 0.7 and 700. However, unlike the laboratory results, for a particular Froude number, the simulations do not show a clear dependence on the magnitude of R(sub f) on Pr. The observed maximum value of R(sub f) is 0.25. When averaged over vertical length scales of an order of magnitude greater than either the overturning or Ozmidov scales of the flow, the simulations indicate that the dissipation rate epsilon is only weakly lognormally distributed with an intermittency of about 0.01 whereas estimated values in the ocean are 3 to 7.

  1. Analysis of environmental contamination resulting from catastrophic incidents: part 1. Building and sustaining capacity in laboratory networks.

    PubMed

    Magnuson, Matthew; Ernst, Hiba; Griggs, John; Fitz-James, Schatzi; Mapp, Latisha; Mullins, Marissa; Nichols, Tonya; Shah, Sanjiv; Smith, Terry; Hedrick, Elizabeth

    2014-11-01

    Catastrophic incidents, such as natural disasters, terrorist attacks, and industrial accidents, can occur suddenly and have high impact. However, they often occur at such a low frequency and in unpredictable locations that planning for the management of the consequences of a catastrophe can be difficult. For those catastrophes that result in the release of contaminants, the ability to analyze environmental samples is critical and contributes to the resilience of affected communities. Analyses of environmental samples are needed to make appropriate decisions about the course of action to restore the area affected by the contamination. Environmental samples range from soil, water, and air to vegetation, building materials, and debris. In addition, processes used to decontaminate any of these matrices may also generate wastewater and other materials that require analyses to determine the best course for proper disposal. This paper summarizes activities and programs the United States Environmental Protection Agency (USEPA) has implemented to ensure capability and capacity for the analysis of contaminated environmental samples following catastrophic incidents. USEPA's focus has been on building capability for a wide variety of contaminant classes and on ensuring national laboratory capacity for potential surges in the numbers of samples that could quickly exhaust the resources of local communities. USEPA's efforts have been designed to ensure a strong and resilient laboratory infrastructure in the United States to support communities as they respond to contamination incidents of any magnitude. The efforts include not only addressing technical issues related to the best-available methods for chemical, biological, and radiological contaminants, but also include addressing the challenges of coordination and administration of an efficient and effective response. Laboratory networks designed for responding to large scale contamination incidents can be sustained by applying their resources during incidents of lesser significance, for special projects, and for routine surveillance and monitoring as part of ongoing activities of the environmental laboratory community. Published by Elsevier Ltd.

  2. Importance of Public-Private Partnerships: Strengthening Laboratory Medicine Systems and Clinical Practice in Africa

    PubMed Central

    Shrivastava, Ritu; Gadde, Renuka; Nkengasong, John N.

    2016-01-01

    After the launch of the US President's Emergency Plan for AIDS Relief in 2003, it became evident that inadequate laboratory systems and services would severely limit the scale-up of human immunodeficiency virus infection prevention, care, and treatment programs. Thus, the Office of the US Global AIDS Coordinator, Centers for Disease Control and Prevention, and Becton, Dickinson and Company developed a public-private partnership (PPP). Between October 2007 and July 2012, the PPP combined the competencies of the public and private sectors to boost sustainable laboratory systems and develop workforce skills in 4 African countries. Key accomplishments of the initiative include measurable and scalable outcomes to strengthen national capacities to build technical skills, develop sample referral networks, map disease prevalence, support evidence-based health programming, and drive continuous quality improvement in laboratories. This report details lessons learned from our experience and a series of recommendations on how to achieve successful PPPs. PMID:27025696

  3. ISDP salt batch #2 supernate qualification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, T. B.; Nash, C. A.; Fink, S. D.

    2009-01-05

    This report covers the laboratory testing and analyses of the second Integrated Salt Disposition Project (ISDP) salt supernate samples, performed in support of initial radioactive operations of Actinide Removal Process (ARP) and Modular Caustic-Side Solvent Extraction Unit (MCU). Major goals of this work include characterizing Tank 22H supernate, characterizing Tank 41H supernate, verifying actinide and strontium adsorption with a standard laboratory-scale test using monosodium titanate (MST) and filtration, and checking cesium mass transfer behavior for the MCU solvent performance when contacted with the liquid produced from MST contact. This study also includes characterization of a post-blend Tank 49H sample asmore » part of the Nuclear Criticality Safety Evaluation (NCSE). This work was specified by Task Technical Request and by Task Technical and Quality Assurance Plan (TTQAP). In addition, a sampling plan will be written to guide analytical future work. Safety and environmental aspects of the work were documented in a Hazard Assessment Package.« less

  4. Uranium hydrogeochemical and stream sediment reconnaissance of the Philip Smith Mountains NTMS quadrangle, Alaska

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-09-01

    Results of a hydrogeochemical and stream sediment reconnaissance of the Philip Smith Mountains NTMS quadrangle, Alaska are presented. In addition to this abbreviated data release, more complete data are available to the public in machine-readable form. In this data release are location data, field analyses, and laboratory analyses of several different sample media. For the sake of brevity, many field site observations have not been included in this volume. These data are, however, available on the magnetic tape. Appendices A and B describe the sample media and summarize the analytical results for each medium. The data were subsetted by onemore » of the Los Alamos National Laboratory (LANL) sorting programs into groups of stream sediment and lake sediment samples. For each group which contains a sufficient number of observations, statistical tables, tables of raw data, and 1:1000000 scale maps of pertinent elements have been included in this report.« less

  5. Magnetic resonance imaging in laboratory petrophysical core analysis

    NASA Astrophysics Data System (ADS)

    Mitchell, J.; Chandrasekera, T. C.; Holland, D. J.; Gladden, L. F.; Fordham, E. J.

    2013-05-01

    Magnetic resonance imaging (MRI) is a well-known technique in medical diagnosis and materials science. In the more specialized arena of laboratory-scale petrophysical rock core analysis, the role of MRI has undergone a substantial change in focus over the last three decades. Initially, alongside the continual drive to exploit higher magnetic field strengths in MRI applications for medicine and chemistry, the same trend was followed in core analysis. However, the spatial resolution achievable in heterogeneous porous media is inherently limited due to the magnetic susceptibility contrast between solid and fluid. As a result, imaging resolution at the length-scale of typical pore diameters is not practical and so MRI of core-plugs has often been viewed as an inappropriate use of expensive magnetic resonance facilities. Recently, there has been a paradigm shift in the use of MRI in laboratory-scale core analysis. The focus is now on acquiring data in the laboratory that are directly comparable to data obtained from magnetic resonance well-logging tools (i.e., a common physics of measurement). To maintain consistency with well-logging instrumentation, it is desirable to measure distributions of transverse (T2) relaxation time-the industry-standard metric in well-logging-at the laboratory-scale. These T2 distributions can be spatially resolved over the length of a core-plug. The use of low-field magnets in the laboratory environment is optimal for core analysis not only because the magnetic field strength is closer to that of well-logging tools, but also because the magnetic susceptibility contrast is minimized, allowing the acquisition of quantitative image voxel (or pixel) intensities that are directly scalable to liquid volume. Beyond simple determination of macroscopic rock heterogeneity, it is possible to utilize the spatial resolution for monitoring forced displacement of oil by water or chemical agents, determining capillary pressure curves, and estimating wettability. The history of MRI in petrophysics is reviewed and future directions considered, including advanced data processing techniques such as compressed sensing reconstruction and Bayesian inference analysis of under-sampled data. Although this review focuses on rock core analysis, the techniques described are applicable in a wider context to porous media in general, such as cements, soils, ceramics, and catalytic materials.

  6. Supplementing the Braden scale for pressure ulcer risk among medical inpatients: the contribution of self-reported symptoms and standard laboratory tests.

    PubMed

    Skogestad, Ingrid Johansen; Martinsen, Liv; Børsting, Tove Elisabet; Granheim, Tove Irene; Ludvigsen, Eirin Sigurdssøn; Gay, Caryl L; Lerdal, Anners

    2017-01-01

    To evaluate medical inpatients' symptom experience and selected laboratory blood results as indicators of their pressure ulcer risk as measured by the Braden scale. Pressure ulcers reduce quality of life and increase treatment costs. The prevalence of pressure ulcers is 6-23% in hospital populations, but literature suggests that most pressure ulcers are avoidable. Prospective, cross-sectional survey. Three hundred and twenty-eight patients admitted to medical wards in an acute hospital in Oslo, Norway consented to participate. Data were collected on 10 days between 2012-2014 by registered nurses and nursing students. Pressure ulcer risk was assessed using the Braden scale, and scores <19 indicated pressure ulcer risk. Skin examinations were categorised as normal or stages I-IV using established definitions. Comorbidities were collected by self-report. Self-reported symptom occurrence and distress were measured with 15 items from the Memorial Symptom Assessment Scale, and pain was assessed using two numeric rating scales. Admission laboratory data were collected from medical records. Prevalence of pressure ulcers was 11·9, and 20·4% of patients were identified as being at risk for developing pressure ulcers. Multivariable analysis showed that pressure ulcer risk was positively associated with age ≥80 years, vomiting, severe pain at rest, urination problems, shortness of breath and low albumin and was negatively associated with nervousness. Our study indicates that using patient-reported symptoms and standard laboratory results as supplemental indicators of pressure ulcer risk may improve identification of vulnerable patients, but replication of these findings in other study samples is needed. Nurses play a key role in preventing pressure ulcers during hospitalisation. A better understanding of the underlying mechanisms may improve the quality of care. Knowledge about symptoms associated with pressure ulcer risk may contribute to a faster clinical judgment of patients at risk. © 2016 John Wiley & Sons Ltd.

  7. Heterogeneity of shales in different scales and its implications to laboratory analyses - examples from sedimentology and organic geochemistry study of the Lower Paleozoic shales from shale gas exploration well located in the Baltic Basin, Poland.

    NASA Astrophysics Data System (ADS)

    Roszkowska-Remin, Joanna; Janas, Marcin

    2017-04-01

    We present the litho-sedimentological, organic geochemical results and organic porosity estimation of the Ordovician and Silurian shales in the SeqWell (shale gas exploration well located in the Pomerania region, Poland). The most perspective black and bituminous shales of the Upper Ordovician and the Lower Silurian may seem to be homogeneous. However, our results reveal that these shales show heterogeneity at different scales (m to mm). For example, in most cases the decrease of TOC content in the m scale is related to pyroclastic rock intercalations and "dark bioturbations" with no color difference when compared with surrounding sediments. While in cm scale heterogeneity is related to bioturbations, density of organic-rich laminas, or abundance of carbonates and pyrite. Without a detailed sedimentological study of polished core surfaces and Rock-Eval analyses those observations are rather invisible. The correct interpretation of results requires the understanding of rock's heterogeneity in different scales. It has a critical importance for laboratory tests applied on few cm long samples, especially if the results are to be extrapolated to wider intervals. Therefore in ShaleSeq project, a detailed sedimentological core logging and analysis of geochemical parameters of perspective formations in m to mm scale was performed for the first time. The results show good correlation between bioturbation index (BI) and organic geochemical indicators like organic carbon content (TOC) or oxic deposition conditions indicator (oxygen index - OI) leading to the assumption that environmental conditions may have played a crucial role in organic carbon preservation. The geochemical analyses of 12 samples showed that even within the few cm long sections shale can be really diversified. Eight out of twelve analyzed samples were considered geochemically mostly homogeneous, whilst four of them showed evident heterogeneity. Concluding, the sampling should be preceded by detailed sedimentological study, as it allows to control if the chosen samples are representative for wider intervals and give opportunity to place the laboratory results in the wider context. An attempt to estimate organic porosity using Rock-Eval data was based on Marathon Oil company study of the Polish Lower Paleozoic shales. The results of this study and suggested equations were used to calculate hypothetical organic porosity of the most perspective shales in the SeqWell. Calculated organic porosities in % bulk volume of rock suggested that organic porosity for Upper Ordovician and Lower Silurian shales in SeqWell may be at the level of 0,1-2,9% in bulk volume of rock. These results would suggest that organic porosity doesn't play a major role in total porosity system in these shales at the certain thermal maturity level. The hypothetical organic porosity values were not validated by the microscopic study though. Our study are part of the ShaleSeq Project co-funded by Norway Grants of the Polish-Norwegian Research Programme operated by the National Centre for Research and Development.

  8. Atmospheric Carbon Dioxide Mixing Ratios from the NOAA CMDL Carbon Cycle Cooperative Global Air Sampling Network (2009)

    DOE Data Explorer

    Conway, Thomas [NOAA Climate Monitoring and Diagnostics Laboratory, Boulder, CO (USA); Tans, Pieter [NOAA Climate Monitoring and Diagnostics Laboratory, Boulder, CO (USA)

    2009-01-01

    The National Oceanic and Atmospheric Administration's Climate Monitoring and Diagnostics Laboratory (NOAA/CMDL) has measured CO2 in air samples collected weekly at a global network of sites since the late 1960s. Atmospheric CO2 mixing ratios reported in these files were measured by a nondispersive infrared absorption technique in air samples collected in glass flasks. All CMDL flask samples are measured relative to standards traceable to the World Meteorological Organization (WMO) CO2 mole fraction scale. These measurements constitute the most geographically extensive, carefully calibrated, internally consistent atmospheric CO2 data set available and are essential for studies aimed at better understanding the global carbon cycle budget.

  9. Ebola Check: Delivering molecular diagnostics at the point of need.

    PubMed

    Moschos, Sterghios A

    2015-01-01

    The 2013-5 global outbreak of Ebolavirus disease brought to sharp focus the need for diagnostic capacity to be equitably available on a global scale: from the most under-developed areas of resource-limited countries in West Africa to high volume international travel hubs in Europe and the USA. Quick detection of the causal agent of disease is pivotal to containment, contact tracing and clinical action to protect healthcare workers, communities and patients. Nucleic acid testing (NAT) by real time reverse transcription quantitative polymerase chain reaction (RT-PCR) has emerged as the preferred method for reliable patient status confirmation. Presently, this is served through advanced clinical molecular laboratory testing in a <8hr manual process that requires 3.5ml venous blood samples. To meet the demand in West Africa, this has necessitated large-scale mobile laboratory and volunteer biomedical scientist deployment: a solution that has proven eventually adequate, albeit temporary against future re-emergence of this and other haemorrhagic fever disease agents prevalent in the region. The EbolaCheck consortium was formed in August 2014 to address the need for delivering NAT at the point of care. We have developed a novel platform technology that can QUantitatively, RAPidly IDentify (QuRapID) known RNA or DNA targets in viruses, bacteria, or eukaryotic cells directly in crude biofluids, including whole blood, in under 40min using a 5 microliter sample. The portable, battery-operated system lacks microfluidics, pumps or other sensitive/high cost parts making it suitable for the environmental and economic challenges of resource-limited countries. The simple, safe, 5-step sample-to-answer process requires minimal training and informs frontline healthcare workers of diagnostic status, whilst reporting remotely epidemiologically relevant results. Data on biosafety level 2 surrogate Ebolavirus templates presented in encapsulated or enveloped viruses indicate performance comparable to clinical laboratory testing and utility beyond filoviruses. Emerging performance data on live Ebolavirus, non-human primate disease model and patient samples, as well as future development plans will be discussed.

  10. Low-Cost Bio-Based Phase Change Materials as an Energy Storage Medium in Building Envelopes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Biswas, Kaushik; Abhari, Mr. Ramin; Shukla, Dr. Nitin

    2015-01-01

    A promising approach to increasing the energy efficiency of buildings is the implementation of phase change material (PCM) in building envelope systems. Several studies have reported the energy saving potential of PCM in building envelopes. However, wide application of PCMs in building applications has been inhibited, in part, by their high cost. This article describes a novel paraffin product made of naturally occurring fatty acids/glycerides trapped into high density polyethylene (HDPE) pellets and its performance in a building envelope application, with the ultimate goal of commercializing a low-cost PCM platform. The low-cost PCM pellets were mixed with cellulose insulation, installedmore » in external walls and field-tested under natural weatherization conditions for a period of several months. In addition, several PCM samples and PCM-cellulose samples were prepared under controlled conditions for laboratory-scale testing. The laboratory tests were performed to determine the phase change properties of PCM-enhanced cellulose insulation both at microscopic and macroscopic levels. This article presents the data and analysis from the exterior test wall and the laboratory-scale test data. PCM behavior is influenced by the weather and interior conditions, PCM phase change temperature and PCM distribution within the wall cavity, among other factors. Under optimal conditions, the field data showed up to 20% reduction in weekly heat transfer through an external wall due to the PCM compared to cellulose-only insulation.« less

  11. Hydrodispersive characterization of a sandy porous medium by tracer tests carried out in laboratory on undisturbed soil samples

    NASA Astrophysics Data System (ADS)

    Ferrante, Aldo Pedro; Fallico, Carmine; Rios, Ana C.; Fernanda Rivera, Maria; Santillan, Patricio; Salazar, Mario

    2013-04-01

    The contamination of large areas and correspondent aquifers often imposes to implement some recovery operations which are generally complex and very expensive. Anyway, these interventions necessarily require the preventive characterization of the aquifers to be reclaimed and in particular the knowledge of the relevant hydrodispersive parameters. The determination of these parameters requires the implementation tracer tests for the specific site (Sauty JP, 1978). To reduce cost and time that such test requires tracer tests on undisturbed soil samples, representative of the whole aquifer, can be performed. These laboratory tests are much less expensive and require less time, but the results are certainly less reliable than those obtained by field tests for several reasons, including the particular scale of investigation. In any case the hydrodispersive parameters values, obtained by tests carried out in laboratory, can provide useful information on the considered aquifer, allowing to carry out initial verifications on the transmission and propagation of the pollutants in the aquifer considered. For this purpose, tracer tests with inlet of short time were carried out in the Soil Physics Laboratory of the Department of Soil Protection (University of Calabria), on a series of sandy soil samples with six different lengths, repeating each test with three different water flow velocities (5 m/d; 10 m/s and 15 m/d) (J. Feyen et al., 1998). The lengths of the samples taken into account are respectively 15 cm, 24 cm, 30 cm, 45 cm, 60 cm and 75 cm, while the solution used for each test was made of 100 ml of water and NaCl with a concentration of this substance corresponding to 10 g/L. For the porous medium taken into consideration a particle size analysis was carried out, resulting primarily made of sand, with total porosity equal to 0.33. Each soil sample was placed in a flow cell in which was inlet the tracer from the bottom upwards, measuring by a conductivimeter the variation of the outgoing concentration over time and obtaining the respective breakthrough curve. The flow was induced and regulated by a peristaltic pump. The results obtained are consistent together with those obtained by other researchers for analogues soil types; moreover the existence of a scaling law for the hydrodispersive parameters considered, ie the longitudinal dispersivity (?L) and the longitudinal dispersion coefficient (DL), was also verified (Neuman S.P., 1990), (Schulze-Makuch D., 2005). References Feyen J. et al., 1998. "Modelling Water Flow and Solute Transport in Heterogeneous Soils: A Review of Recent Approaches", Silsoe Research Institute. Neuman S.P., 1990. "Universal Scaling of Hydraulic Conductivities and Dispersivities in Geologic Media", Water Resources Research, vol. 26. Schulze-Makuch D., 2005. "Longitudinal Dispersivity Data and Implications for Scaling Behavior", Ground Water, vol.43. Sauty J.P., 1978. "Identification des paramètres du transport hydrodispersif dans les aquifères par interprétation de traçages en ecoulement cylindrique convergent ou divergent", Journal of hydrology n. 39.

  12. 3D chemical imaging in the laboratory by hyperspectral X-ray computed tomography

    PubMed Central

    Egan, C. K.; Jacques, S. D. M.; Wilson, M. D.; Veale, M. C.; Seller, P.; Beale, A. M.; Pattrick, R. A. D.; Withers, P. J.; Cernik, R. J.

    2015-01-01

    We report the development of laboratory based hyperspectral X-ray computed tomography which allows the internal elemental chemistry of an object to be reconstructed and visualised in three dimensions. The method employs a spectroscopic X-ray imaging detector with sufficient energy resolution to distinguish individual elemental absorption edges. Elemental distributions can then be made by K-edge subtraction, or alternatively by voxel-wise spectral fitting to give relative atomic concentrations. We demonstrate its application to two material systems: studying the distribution of catalyst material on porous substrates for industrial scale chemical processing; and mapping of minerals and inclusion phases inside a mineralised ore sample. The method makes use of a standard laboratory X-ray source with measurement times similar to that required for conventional computed tomography. PMID:26514938

  13. Solar photo-Fenton treatment of carbofuran: analysis of mineralization, toxicity, and organic by-products.

    PubMed

    Lopez-Alvarez, Blady; Torres-Palma, Ricardo A; Ferraro, Franklin; Peñuela, Gustavo

    2012-01-01

    The degradation of the pesticide carbofuran (CBF) using solar photo-Fenton treatment, at both the laboratory and the pilot scale, was evaluated. At the laboratory scale, in a suntest reactor, the Fe(2+) concentration and H(2)O(2) concentration were evaluated and optimized using the surface response methodology and the Pareto diagram. Under optimal conditions experiments were performed to evaluate the evolution of the substrate removal, oxidation, subsequent mineralization, toxicity and the formation of chloride ions during the treatment. The analysis and evolution of five CBF by-products as well as several control and reactivity tests at the density functional theory level were used to depict a general scheme of the main degradation pathway of CBF via the photo-Fenton system. Finally, at the pilot scale, a sample of the commercial CBF product Furadan was eliminated after 420 min by the photo-Fenton system using direct sunlight. Under these conditions, after 900 min 89% of toxicity (1/E(50) on Vibrio fischeri bacteria), 97% of chemical oxygen demand, and 90% of dissolved organic carbon were removed.

  14. Permeability and compression characteristics of municipal solid waste samples

    NASA Astrophysics Data System (ADS)

    Durmusoglu, Ertan; Sanchez, Itza M.; Corapcioglu, M. Yavuz

    2006-08-01

    Four series of laboratory tests were conducted to evaluate the permeability and compression characteristics of municipal solid waste (MSW) samples. While the two series of tests were conducted using a conventional small-scale consolidometer, the two others were conducted in a large-scale consolidometer specially constructed for this study. In each consolidometer, the MSW samples were tested at two different moisture contents, i.e., original moisture content and field capacity. A scale effect between the two consolidometers with different sizes was investigated. The tests were carried out on samples reconsolidated to pressures of 123, 246, and 369 kPa. Time settlement data gathered from each load increment were employed to plot strain versus log-time graphs. The data acquired from the compression tests were used to back calculate primary and secondary compression indices. The consolidometers were later adapted for permeability experiments. The values of indices and the coefficient of compressibility for the MSW samples tested were within a relatively narrow range despite the size of the consolidometer and the different moisture contents of the specimens tested. The values of the coefficient of permeability were within a band of two orders of magnitude (10-6-10-4 m/s). The data presented in this paper agreed very well with the data reported by previous researchers. It was concluded that the scale effect in the compression behavior was significant. However, there was usually no linear relationship between the results obtained in the tests.

  15. Persistence in soil of Miscanthus biochar in laboratory and field conditions

    PubMed Central

    Budai, Alice; O’Toole, Adam; Ma, Xingzhu; Rumpel, Cornelia; Abiven, Samuel

    2017-01-01

    Evaluating biochars for their persistence in soil under field conditions is an important step towards their implementation for carbon sequestration. Current evaluations might be biased because the vast majority of studies are short-term laboratory incubations of biochars produced in laboratory-scale pyrolyzers. Here our objective was to investigate the stability of a biochar produced with a medium-scale pyrolyzer, first through laboratory characterization and stability tests and then through field experiment. We also aimed at relating properties of this medium-scale biochar to that of a laboratory-made biochar with the same feedstock. Biochars were made of Miscanthus biomass for isotopic C-tracing purposes and produced at temperatures between 600 and 700°C. The aromaticity and degree of condensation of aromatic rings of the medium-scale biochar was high, as was its resistance to chemical oxidation. In a 90-day laboratory incubation, cumulative mineralization was 0.1% for the medium-scale biochar vs. 45% for the Miscanthus feedstock, pointing to the absence of labile C pool in the biochar. These stability results were very close to those obtained for biochar produced at laboratory-scale, suggesting that upscaling from laboratory to medium-scale pyrolyzers had little effect on biochar stability. In the field, the medium-scale biochar applied at up to 25 t C ha-1 decomposed at an estimated 0.8% per year. In conclusion, our biochar scored high on stability indices in the laboratory and displayed a mean residence time > 100 years in the field, which is the threshold for permanent removal in C sequestration projects. PMID:28873471

  16. Refractory Organics in Comet 67P Churyumov-Gerasimenko: Additional Evidence for Large-scale Mixing in the Primitive Solar Nebula?

    NASA Technical Reports Server (NTRS)

    Nuth, J. A.; Johnson, N. M.; Ferguson, F. T.; Hilchenbach, M.; Merouane, S.; Paquette, J. A.; Stenzel, O.; Cottin, H.; Fray, N.; Bardyn, A.; hide

    2017-01-01

    The COSIMA instrument onboard the Rosetta spacecraft collected and analyzed samples of individual particles from the coma of Comet67P/ Churyumov-Gerasimenko. Initial results of the analysis of several particles have been presented elsewhere while analyses of the organic component of the dust particles has been shown to compare favor ably to laboratory spectra of IOM extracted from the Orguil and Murchison meteorites. Here we will compare the spectra of the same two particles to laboratory spectra of organic grain coatings produced via Surface Mediated Reactions of CO, H2 and N2 on amorphous iron silicate grains.

  17. Availability of feature-oriented scanning probe microscopy for remote-controlled measurements on board a space laboratory or planet exploration Rover.

    PubMed

    Lapshin, Rostislav V

    2009-06-01

    Prospects for a feature-oriented scanning (FOS) approach to investigations of sample surfaces, at the micrometer and nanometer scales, with the use of scanning probe microscopy under space laboratory or planet exploration rover conditions, are examined. The problems discussed include decreasing sensitivity of the onboard scanning probe microscope (SPM) to temperature variations, providing autonomous operation, implementing the capabilities for remote control, self-checking, self-adjustment, and self-calibration. A number of topical problems of SPM measurements in outer space or on board a planet exploration rover may be solved via the application of recently proposed FOS methods.

  18. Evaluation of groundwater quality and assessment of scaling potential and corrosiveness of water samples in Kadkan aquifer, Khorasan-e-Razavi Province, Iran.

    PubMed

    Esmaeili-Vardanjani, Mostafa; Rasa, Iraj; Amiri, Vahab; Yazdi, Mohammad; Pazand, Kaveh

    2015-02-01

    The chemical analysis of 129 groundwater samples in the Kadkan area, Khorasan-e-Razavi Province, NE of Iran was evaluated to determine the hydrochemical processes, assessment of groundwater quality for irrigation purposes, corrosiveness, and scaling potential of the groundwater. Accordingly, the suitability of groundwater for irrigation was evaluated based on the sodium adsorption ratio, residual sodium carbonate, sodium percent, salinity hazard, and US Salinity Laboratory hazard diagram. Based on the electrical conductivity and sodium adsorption ratio, the dominant classes are C3-S1, C3-S2, C2-S1, and C4-S2. According to the Wilcox plot, about 50 % of the samples fall in the "Excellent to Good" and "Good to Permissible" classes. Besides, the Langelier saturation index, Ryznar stability index (RSI), Larson-Skold index, and Puckorius scaling index were evaluated for assessing the corrosiveness and scaling potential of the groundwater. Corrosiveness and scaling indices stated that the majority of samples are classified into "Aggressive" and "Very Aggressive" category. In addition, chloride and sulfate interfere in 90 % of the samples. Assessment of hydrochemical characteristics indicates Na-Mg-Cl as the predominant hydrochemical type. Spatial distribution of hydrochemical parameters indicates that hydrochemical processes are influenced by geology and hydrogeology of Kadkan aquifer. The Gibbs plots gave an indication that groundwater chemistry in this area may have acquired the chemistry mainly from evaporation and mineral precipitation. Grouping the samples based on Q-mode hierarchical cluster analysis helped to more separation of similar samples. The R-mode HCA grouped analyzed parameters into two groups based on similarity of hydrochemical characteristics. As a result, the samples collected in northern and southern parts of the study area show the best quality (i.e., lowest salinity) for some purposes such as irrigation and drinking.

  19. Fracture induced electromagnetic emissions: extending laboratory findings by observations at the geophysical scale

    NASA Astrophysics Data System (ADS)

    Potirakis, Stelios M.; Contoyiannis, Yiannis; Kopanas, John; Kalimeris, Anastasios; Antonopoulos, George; Peratzakis, Athanasios; Eftaxias, Konstantinos; Nomicos, Constantinos

    2014-05-01

    Under natural conditions, it is practically impossible to install an experimental network on the geophysical scale using the same instrumentations as in laboratory experiments for understanding, through the states of stress and strain and their time variation, the laws that govern the friction during the last stages of EQ generation, or to monitor (much less to control) the principal characteristics of a fracture process. Fracture-induced electromagnetic emissions (EME) in a wide range of frequency bands are sensitive to the micro-structural chances. Thus, their study constitutes a nondestructive method for the monitoring of the evolution of damage process at the laboratory scale. It has been suggested that fracture induced MHz-kHz electromagnetic (EM) emissions, which emerge from a few days up to a few hours before the main seismic shock occurrence permit a real time monitoring of the damage process during the last stages of earthquake preparation, as it happens at the laboratory scale. Since the EME are produced both in the case of the laboratory scale fracture and the EQ preparation process (geophysical scale fracture) they should present similar characteristics in these two scales. Therefore, both the laboratory experimenting scientists and the experimental scientists studying the pre-earthquake EME could benefit from each- other's results. Importantly, it is noted that when studying the fracture process by means of laboratory experiments, the fault growth process normally occurs violently in a fraction of a second. However, a major difference between the laboratory and natural processes is the order-of-magnitude differences in scale (in space and time), allowing the possibility of experimental observation at the geophysical scale for a range of physical processes which are not observable at the laboratory scale. Therefore, the study of fracture-induced EME is expected to reveal more information, especially for the last stages of the fracture process, when it is conducted at the geophysical scale. As a characteristic example, we discuss about the case of electromagnetic silence before the global rupture that was first observed in preseismic EME and recently was also observed in the EME measured during laboratory fracture experiments, completely revising the earlier views about the fracture-induced electromagnetic emissions.

  20. Reliability and validity of the upper-extremity Motor Activity Log-14 for measuring real-world arm use.

    PubMed

    Uswatte, Gitendra; Taub, Edward; Morris, David; Vignolo, Mary; McCulloch, Karen

    2005-11-01

    In research on Constraint-Induced Movement (CI) therapy, a structured interview, the Motor Activity Log (MAL), is used to assess how stroke survivors use their more-impaired arm outside the laboratory. This article examines the psychometrics of the 14-item version of this instrument in 2 chronic stroke samples with mild-to-moderate upper-extremity hemiparesis. Participants (n=41) in the first study completed MALs before and after CI therapy or a placebo control procedure. In addition, caregivers independently completed a MAL on the participants. Participants (n=27) in the second study completed MALs and wore accelerometers that monitored their arm movements for 3 days outside the laboratory before and after an automated form of CI therapy. Validity of the participant MAL Quality of Movement (QOM) scale was supported. Correlations between pretreatment-to-posttreatment change scores on the participant QOM scale and caregiver MAL QOM scale, caregiver MAL amount of use (AOU) scale, and accelerometer recordings were 0.70, 0.73, and 0.91 (P<0.01), respectively. Internal consistency (alpha>0.81), test-retest reliability (r>0.91), stability, and responsiveness (ratio>3) of the participant QOM scale were also supported. The participant AOU and caregiver QOM and AOU scales were internally consistent, stable, and sensitive, but were not reliable. The participant MAL QOM scale can be used exclusively to reliably and validly measure real-world, upper-extremity rehabilitation outcome and functional status in chronic stroke patients with mild-to-moderate hemiparesis.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shettel, D.L. Jr.; Langfeldt, S.L.; Youngquist, C.A.

    This report presents a Hydrogeochemical and Stream Sediment Reconnaissance of the Christian NTMS Quadrangle, Alaska. In addition to this abbreviated data release, more complete data are available to the public in machine-readable form. These machine-readable data, as well as quarterly or semiannual program progress reports containing further information on the HSSR program in general, or on the Los Alamos National Laboratory portion of the program in particular, are available from DOE's Technical Library at its Grand Junction Area Office. Presented in this data release are location data, field analyses, and laboratory analyses of several different sample media. For the sakemore » of brevity, many field site observations have not been included in this volume; these data are, however, available on the magnetic tape. Appendices A through D describe the sample media and summarize the analytical results for each medium. The data have been subdivided by one of the Los Alamos National Laboratory sorting programs of Zinkl and others (1981a) into groups of stream-sediment, lake-sediment, stream-water, lake-water, and ground-water samples. For each group which contains a sufficient number of observations, statistical tables, tables of raw data, and 1:1,000,000 scale maps of pertinent elements have been included in this report. Also included are maps showing results of multivariate statistical analyses.« less

  2. Laboratory-Measured and Property-Transfer Modeled Saturated Hydraulic Conductivity of Snake River Plain Aquifer Sediments at the Idaho National Laboratory, Idaho

    USGS Publications Warehouse

    Perkins, Kim S.

    2008-01-01

    Sediments are believed to comprise as much as 50 percent of the Snake River Plain aquifer thickness in some locations within the Idaho National Laboratory. However, the hydraulic properties of these deep sediments have not been well characterized and they are not represented explicitly in the current conceptual model of subregional scale ground-water flow. The purpose of this study is to evaluate the nature of the sedimentary material within the aquifer and to test the applicability of a site-specific property-transfer model developed for the sedimentary interbeds of the unsaturated zone. Saturated hydraulic conductivity (Ksat) was measured for 10 core samples from sedimentary interbeds within the Snake River Plain aquifer and also estimated using the property-transfer model. The property-transfer model for predicting Ksat was previously developed using a multiple linear-regression technique with bulk physical-property measurements (bulk density [pbulk], the median particle diameter, and the uniformity coefficient) as the explanatory variables. The model systematically underestimates Ksat,typically by about a factor of 10, which likely is due to higher bulk-density values for the aquifer samples compared to the samples from the unsaturated zone upon which the model was developed. Linear relations between the logarithm of Ksat and pbulk also were explored for comparison.

  3. International Intercomparison of Regular Transmittance Scales

    NASA Astrophysics Data System (ADS)

    Eckerle, K. L.; Sutter, E.; Freeman, G. H. C.; Andor, G.; Fillinger, L.

    1990-01-01

    An intercomparison of the regular spectral transmittance scales of NIST, Gaithersburg, MD (USA); PTB, Braunschweig (FRG); NPL, Teddington, Middlesex (UK); and OMH, Budapest (H) was accomplished using three sets of neutral glass filters with transmittances ranging from approximately 0.92 to 0.001. The difference between the results from the reference spectrophotometers of the laboratories was generally smaller than the total uncertainty of the interchange. The relative total uncertainty ranges from 0.05% to 0.75% for transmittances from 0.92 to 0.001. The sample-induced error was large - contributing 40% or more of the total except in a few cases.

  4. Design and fabrication of a glovebox for the Plasma Hearth Process radioactive bench-scale system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wahlquist, D.R.

    This paper presents some of the design considerations and fabrication techniques for building a glovebox for the Plasma Hearth Process (PHP) radioactive bench-scale system. The PHP radioactive bench-scale system uses a plasma torch to process a variety of radioactive materials into a final vitrified waste form. The processed waste will contain plutonium and trace amounts of other radioactive materials. The glovebox used in this system is located directly below the plasma chamber and is called the Hearth Handling Enclosure (HHE). The HHE is designed to maintain a confinement boundary between the processed waste and the operator. Operations that take placemore » inside the HHE include raising and lowering the hearth using a hydraulic lift table, transporting the hearth within the HHE using an overhead monorail and hoist system, sampling and disassembly of the processed waste and hearth, weighing the hearth, rebuilding a hearth, and sampling HEPA filters. The PHP radioactive bench-scale system is located at the TREAT facility at Argonne National Laboratory-West in Idaho Falls, Idaho.« less

  5. Approximate Seismic Diffusive Models of Near-Receiver Geology: Applications from Lab Scale to Field

    NASA Astrophysics Data System (ADS)

    King, Thomas; Benson, Philip; De Siena, Luca; Vinciguerra, Sergio

    2017-04-01

    This paper presents a novel and simple method of seismic envelope analysis that can be applied at multiple scales, e.g. field, m to km scale and laboratory, mm to cm scale, and utilises the diffusive approximation of the seismic wavefield (Wegler, 2003). Coefficient values for diffusion and attenuation are obtained from seismic coda energies and are used to describe the rate at which seismic energy is scattered and attenuated into the local medium around a receiver. Values are acquired by performing a linear least squares inversion of coda energies calculated in successive time windows along a seismic trace. Acoustic emission data were taken from piezoelectric transducers (PZT) with typical resonance frequency of 1-5MHz glued around rock samples during deformation laboratory experiments carried out using a servo-controlled triaxial testing machine, where a shear/damage zone is generated under compression after the nucleation, growth and coalescence of microcracks. Passive field data were collected from conventional geophones during the 2004-2008 eruption of Mount St. Helens volcano (MSH), USA where a sudden reawakening of the volcanic activity and a new dome growth has occurred. The laboratory study shows a strong correlation between variations of the coefficients over time and the increase of differential stress as the experiment progresses. The field study links structural variations present in the near-surface geology, including those seen in previous geophysical studies of the area, to these same coefficients. Both studies show a correlation between frequency and structural feature size, i.e. landslide slip-planes and microcracks, with higher frequencies being much more sensitive to smaller scale features and vice-versa.

  6. Measurement of unsaturated hydraulic properties and evaluation of property-transfer models for deep sedimentary interbeds, Idaho National Laboratory, Idaho

    USGS Publications Warehouse

    Perkins, Kimberlie; Johnson, Brittany D.; Mirus, Benjamin B.

    2014-01-01

    During 2013–14, the USGS, in cooperation with the U.S. Department of Energy, focused on further characterization of the sedimentary interbeds below the future site of the proposed Remote Handled Low-Level Waste (RHLLW) facility, which is intended for the long-term storage of low-level radioactive waste. Twelve core samples from the sedimentary interbeds from a borehole near the proposed facility were collected for laboratory analysis of hydraulic properties, which also allowed further testing of the property-transfer modeling approach. For each core sample, the steady-state centrifuge method was used to measure relations between matric potential, saturation, and conductivity. These laboratory measurements were compared to water-retention and unsaturated hydraulic conductivity parameters estimated using the established property-transfer models. For each core sample obtained, the agreement between measured and estimated hydraulic parameters was evaluated quantitatively using the Pearson correlation coefficient (r). The highest correlation is for saturated hydraulic conductivity (Ksat) with an r value of 0.922. The saturated water content (qsat) also exhibits a strong linear correlation with an r value of 0.892. The curve shape parameter (λ) has a value of 0.731, whereas the curve scaling parameter (yo) has the lowest r value of 0.528. The r values demonstrate that model predictions correspond well to the laboratory measured properties for most parameters, which supports the value of extending this approach for quantifying unsaturated hydraulic properties at various sites throughout INL.

  7. Dehydration-driven stress transfer triggers intermediate-depth earthquakes

    NASA Astrophysics Data System (ADS)

    Ferrand, Thomas P.; Hilairet, Nadège; Incel, Sarah; Deldicque, Damien; Labrousse, Loïc; Gasc, Julien; Renner, Joerg; Wang, Yanbin; Green, Harry W., II; Schubnel, Alexandre

    2017-05-01

    Intermediate-depth earthquakes (30-300 km) have been extensively documented within subducting oceanic slabs, but their mechanics remains enigmatic. Here we decipher the mechanism of these earthquakes by performing deformation experiments on dehydrating serpentinized peridotites (synthetic antigorite-olivine aggregates, minerals representative of subduction zones lithologies) at upper mantle conditions. At a pressure of 1.1 gigapascals, dehydration of deforming samples containing only 5 vol% of antigorite suffices to trigger acoustic emissions, a laboratory-scale analogue of earthquakes. At 3.5 gigapascals, acoustic emissions are recorded from samples with up to 50 vol% of antigorite. Experimentally produced faults, observed post-mortem, are sealed by fluid-bearing micro-pseudotachylytes. Microstructural observations demonstrate that antigorite dehydration triggered dynamic shear failure of the olivine load-bearing network. These laboratory analogues of intermediate-depth earthquakes demonstrate that little dehydration is required to trigger embrittlement. We propose an alternative model to dehydration-embrittlement in which dehydration-driven stress transfer, rather than fluid overpressure, causes embrittlement.

  8. A Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) for In-Situ Mars Surface Sample Analysis

    NASA Technical Reports Server (NTRS)

    Edmunson, J.; Gaskin, J. A.; Jerman, G. A.; Harvey, R. P.; Doloboff, I. J.; Neidholdt, E. L.

    2016-01-01

    The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) project, funded by the NASA Planetary Instrument Concepts for the Advancement of Solar System Observations (PICASSO) Research Opportunities in Space and Earth Sciences (ROSES), will build upon previous miniaturized SEM designs and recent advancements in variable pressure SEM's to design and build a SEM to complete analyses of samples on the surface of Mars using the atmosphere as an imaging medium. This project is a collaboration between NASA Marshall Space Flight Center (MSFC), the Jet Propulsion Laboratory (JPL), electron gun and optics manufacturer Applied Physics Technologies, and small vacuum system manufacturer Creare. Dr. Ralph Harvery and environmental SEM (ESEM) inventor Dr. Gerry Danilatos serve as advisors to the team. Variable pressure SEMs allow for fine (nm-scale) resolution imaging and micron-scale chemical study of materials without sample preparation (e.g., carbon or gold coating). Charging of a sample is reduced or eliminated by the gas surrounding the sample. It is this property of ESEMs that make them ideal for locations where sample preparation is not yet feasible, such as the surface of Mars. In addition, the lack of sample preparation needed here will simplify the sample acquisition process and allow caching of the samples for future complementary payload use.

  9. Transport and attenuation of carboxylate-modified latex microspheres in fractured rock laboratory and field tracer tests

    USGS Publications Warehouse

    Becker, M.W.; Reimus, P.W.; Vilks, P.

    1999-01-01

    Understanding colloid transport in ground water is essential to assessing the migration of colloid-size contaminants, the facilitation of dissolved contaminant transport by colloids, in situ bioremediation, and the health risks of pathogen contamination in drinking water wells. Much has been learned through laboratory and field-scale colloid tracer tests, but progress has been hampered by a lack of consistent tracer testing methodology at different scales and fluid velocities. This paper presents laboratory and field tracer tests in fractured rock that use the same type of colloid tracer over an almost three orders-of-magnitude range in scale and fluid velocity. Fluorescently-dyed carboxylate-modified latex (CML) microspheres (0.19 to 0.98 ??m diameter) were used as tracers in (1) a naturally fractured tuff sample, (2) a large block of naturally fractured granite, (3) a fractured granite field site, and (4) another fractured granite/schist field site. In all cases, the mean transport time of the microspheres was shorter than the solutes, regardless of detection limit. In all but the smallest scale test, only a fraction of the injected microsphere mass was recovered, with the smaller microspheres being recovered to a greater extent than the larger microspheres. Using existing theory, we hypothesize that the observed microsphere early arrival was due to volume exclusion and attenuation was due to aggregation and/or settling during transport. In most tests, microspheres were detected using flow cytometry, which proved to be an excellent method of analysis. CML microspheres appear to be useful tracers for fractured rock in forced gradient and short-term natural gradient tests, but longer residence times may result in small microsphere recoveries.Understanding colloid transport in ground water is essential to assessing the migration of colloid-size contaminants, the facilitation of dissolved contaminant transport by colloids, in situ bioremediation, and the health risks of pathogen contamination in drinking water wells. Much has been learned through laboratory and field-scale colloid tracer tests, but progress has been hampered by a lack of consistent tracer testing methodology at different scales and fluid velocities. This paper presents laboratory and field tracer tests in fractured rock that use the same type of colloid tracer over an almost three orders-of-magnitude range in scale and fluid velocity. Fluorescently-dyed carboxylate-modified latex (CML) microspheres (0.19 to 0.98 ??m diameter) were used as tracers in (1) a naturally fractured tuff sample, (2) a large block of naturally fractured granite, (3) a fractured granite field site, and (4) another fractured granite/schist field site. In all cases, the mean transport time of the microspheres was shorter than the solutes, regardless of detection limit. In all but the smallest scale test, only a fraction of the injected microsphere mass was recovered, with the smaller microspheres being recovered to a greater extent than the larger microspheres. Using existing theory, we hypothesize that the observed microsphere early arrival was due to volume exclusion and attenuation was due to aggregation and/or settling during transport. In most tests, microspheres were detected using flow cytometry, which proved to be an excellent method of analysis. CML microspheres appear to be useful tracers for fractured rock in forced gradient and short-term natural gradient tests, but longer residence times may result in small microsphere recoveries.

  10. Correlations of Clinical and Laboratory Measures of Balance in Older Men and Women: The MOBILIZE Boston Study

    PubMed Central

    Nguyen, Uyen-Sa D.T.; Kiel, Douglas P.; Li, Wenjun; Galica, Andrew M.; Kang, Hyun Gu; Casey, Virginia A.; Hannan, Marian T.

    2012-01-01

    Objective Impaired balance is associated with falls in older adults. However, there is no accepted gold standard on how balance should be measured. Few studies have examined measures of postural sway and clinical balance concurrently in large samples of community-dwelling older adults. We examined the associations among four types of measures of laboratory- and clinic-based balance in a large population-based cohort of older adults. Methods We evaluated balance measures in the MOBILIZE Boston Study (276 men, 489 women, 64–97 years). Measures included: (1) laboratory-based anteroposterior (AP) path length and average sway speed, mediolateral (ML) average sway and root-mean-square, and area of ellipse postural sway; (2) Short Physical Performance Battery (SPPB); (3) Berg Balance Scale; and (4) one-leg stand. Spearman Rank Correlation Coefficients (r) were assessed among the balance measures. Results Area of ellipse sway was highly correlated with the ML sway measures (r >0.9, p < 0.0001), and sway speed was highly correlated with AP sway (r=0.97, p < 0.0001). The Berg Balance Scale was highly correlated with SPPB (r=0.7, p<0.001), and one-leg stand (r=0.8, p<0.001). Correlations between the laboratory- and clinic-based balance measures were low but statistically significant (0.2 < r < 0.3, p<0.0001). Conclusion Clinic-based balance measures, and laboratory-based measures comparing area of ellipse with ML sways or sway speed with AP sway, are highly correlated. Clinic- with laboratory-based measures are less correlated. As both laboratory- and clinic-based measures inform balance in older adults but are not highly correlated with each other, future work should investigate the differences. PMID:22745045

  11. ANALYSIS OF 2H-EVAPORATOR SCALE WALL [HTF-13-82] AND POT BOTTOM [HTF-13-77] SAMPLES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oji, L.

    2013-06-21

    Savannah River Remediation (SRR) is planning to remove a buildup of sodium aluminosilicate scale from the 2H-evaporator pot by loading and soaking the pot with heated 1.5 M nitric acid solution. Sampling and analysis of the scale material has been performed so that uranium and plutonium isotopic analysis can be input into a Nuclear Criticality Safety Assessment (NCSA) for scale removal by chemical cleaning. Historically, since the operation of the Defense Waste Processing Facility (DWPF), silicon in the DWPF recycle stream combines with aluminum in the typical tank farm supernate to form sodium aluminosilicate scale mineral deposits in the 2Hevaporatormore » pot and gravity drain line. The 2H-evaporator scale samples analyzed by Savannah River National Laboratory (SRNL) came from the bottom cone sections of the 2H-evaporator pot [Sample HTF-13-77] and the wall 2H-evaporator [sample HTF-13-82]. X-ray diffraction analysis (XRD) confirmed that both the 2H-evaporator pot scale and the wall samples consist of nitrated cancrinite (a crystalline sodium aluminosilicate solid) and clarkeite (a uranium oxy-hydroxide mineral). On “as received” basis, the bottom pot section scale sample contained an average of 2.59E+00 ± 1.40E-01 wt % total uranium with a U-235 enrichment of 6.12E-01 ± 1.48E-02 %, while the wall sample contained an average of 4.03E+00 ± 9.79E-01 wt % total uranium with a U-235 enrichment of 6.03E-01% ± 1.66E-02 wt %. The bottom pot section scale sample analyses results for Pu-238, Pu-239, and Pu-241 are 3.16E- 05 ± 5.40E-06 wt %, 3.28E-04 ± 1.45E-05 wt %, and <8.80E-07 wt %, respectively. The evaporator wall scale samples analysis values for Pu-238, Pu-239, and Pu-241 averages 3.74E-05 ± 6.01E-06 wt %, 4.38E-04 ± 5.08E-05 wt %, and <1.38E-06 wt %, respectively. The Pu-241 analyses results, as presented, are upper limit values. These results are provided so that SRR can calculate the equivalent uranium-235 concentrations for the NCSA. Results confirm that the uranium contained in the scale remains depleted with respect to natural uranium. SRNL did not calculate an equivalent U-235 enrichment, which takes into account other fissionable isotopes U-233, Pu-239 and Pu-241. The applicable method for calculation of equivalent U-235 will be determined in the NCSA.« less

  12. Synchronous in-field application of life-detection techniques in planetary analog missions

    NASA Astrophysics Data System (ADS)

    Amador, Elena S.; Cable, Morgan L.; Chaudry, Nosheen; Cullen, Thomas; Gentry, Diana; Jacobsen, Malene B.; Murukesan, Gayathri; Schwieterman, Edward W.; Stevens, Adam H.; Stockton, Amanda; Yin, Chang; Cullen, David C.; Geppert, Wolf

    2015-02-01

    Field expeditions that simulate the operations of robotic planetary exploration missions at analog sites on Earth can help establish best practices and are therefore a positive contribution to the planetary exploration community. There are many sites in Iceland that possess heritage as planetary exploration analog locations and whose environmental extremes make them suitable for simulating scientific sampling and robotic operations. We conducted a planetary exploration analog mission at two recent lava fields in Iceland, Fimmvörðuháls (2010) and Eldfell (1973), using a specially developed field laboratory. We tested the utility of in-field site sampling down selection and tiered analysis operational capabilities with three life detection and characterization techniques: fluorescence microscopy (FM), adenine-triphosphate (ATP) bioluminescence assay, and quantitative polymerase chain reaction (qPCR) assay. The study made use of multiple cycles of sample collection at multiple distance scales and field laboratory analysis using the synchronous life-detection techniques to heuristically develop the continuing sampling and analysis strategy during the expedition. Here we report the operational lessons learned and provide brief summaries of scientific data. The full scientific data report will follow separately. We found that rapid in-field analysis to determine subsequent sampling decisions is operationally feasible, and that the chosen life detection and characterization techniques are suitable for a terrestrial life-detection field mission. In-field analysis enables the rapid obtainment of scientific data and thus facilitates the collection of the most scientifically relevant samples within a single field expedition, without the need for sample relocation to external laboratories. The operational lessons learned in this study could be applied to future terrestrial field expeditions employing other analytical techniques and to future robotic planetary exploration missions.

  13. Assessing the Implicit Theory of Willpower for Strenuous Mental Activities Scale: Multigroup, across-gender, and cross-cultural measurement invariance and convergent and divergent validity.

    PubMed

    Napolitano, Christopher M; Job, Veronika

    2018-05-21

    Why do some people struggle with self-control (colloquially called willpower) whereas others are able to sustain it during challenging circumstances? Recent research showed that a person's implicit theories of willpower-whether they think self-control capacity is a limited or nonlimited resource-predict sustained self-control on laboratory tasks and on goal-related outcomes in everyday life. The present research tests the Implicit Theory of Willpower for Strenuous Mental Activities Scale (or ITW-M) Scale for measurement invariance across samples and gender within each culture, and two cultural contexts (the U.S. and Switzerland/Germany). Across a series of multigroup confirmatory factor analyses, we found support for the measurement invariance of the ITW-M scale across samples within and across two cultures, as well as across men and women. Further, the analyses showed expected patterns of convergent (with life-satisfaction and trait-self-control) and discriminant validity (with implicit theory of intelligence). These results provide guidelines for future research and clinical practice using the ITW-M scale for the investigation of latent group differences, for example, between gender or cultures. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  14. 30 CFR 14.21 - Laboratory-scale flame test apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Laboratory-scale flame test apparatus. 14.21 Section 14.21 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING... Technical Requirements § 14.21 Laboratory-scale flame test apparatus. The principal parts of the apparatus...

  15. 30 CFR 14.21 - Laboratory-scale flame test apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Laboratory-scale flame test apparatus. 14.21 Section 14.21 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING... Technical Requirements § 14.21 Laboratory-scale flame test apparatus. The principal parts of the apparatus...

  16. Quality Assessment of Physical and Organoleptic Instant Corn Rice on Scale-Up Process

    NASA Astrophysics Data System (ADS)

    Kumalasari, R.; Ekafitri, R.; Indrianti, N.

    2017-12-01

    Development of instant corn rice product has been successfully conducted on a laboratory scale. Corn has high carbohydrate content but low in fiber. The addition of fiber in instant corn rice, intended to improve the functioning of the product, and replace fiber loss during the process. Scale up process of Instant corn rice required to increase the production capacity. Scale up was the process to get identic output on a larger scale based on predetermined production scale. This study aimed to assess the changes and differences in the quality of instant corn rice during scale up. Instant corn rice scale up was done on production capacity 3 kg, 4 kg and 5 kg. Results showed that scale up of instant corn rice producing products with rehydration ratio ranges between 514% - 570%, the absorption rate ranged between 414% - 470%, swelling rate ranging between 119% - 134%, bulk density ranged from 0.3661 to 0.4745 (g/ml) and porosity ranging between 30-37%. The physical quality of instant corn rice on scale up were stable from the ones at laboratory scale on swelling rate, rehydration ratio, and absorption rate but not stable on bulk density and porosity. Organoleptic qualities were stable at increased scale compared on a laboratory scale. Bulk density was higher than those at laboratory scale, and the porosity was lower than those at laboratory scale.

  17. Recovery of Rare Earth Elements from Coal and Coal Byproducts via a Closed Loop Leaching Process: Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peterson, Richard; Heinrichs, Michael; Argumedo, Darwin

    Objectives: Through this grant, Battelle proposes to address Area of Interest (AOI) 1 to develop a bench-scale technology to economically separate, extract, and concentrate mixed REEs from coal ash. U.S. coal and coal byproducts provide the opportunity for a domestic source of REEs. The DOE’s National Energy Technology Laboratory (NETL) has characterized various coal and coal byproducts samples and has found varying concentrations of REE ranging up to 1,000 parts per million by weight. The primary project objective is to validate the economic viability of recovering REEs from the coal byproduct coal ash using Battelle’s patented closed-loop Acid Digestion Processmore » (ADP). This will be accomplished by selecting coal sources with the potential to provide REE concentrations above 300 parts per million by weight, collecting characterization data for coal ash samples generated via three different methods, and performing a Techno-Economic Analysis (TEA) for the proposed process. The regional availability of REE-laden coal ash, the regional market for rare earth concentrates, and the system capital and operating costs for rare earth recovery using the ADP technology will be accounted for in the TEA. Limited laboratory testing will be conducted to generate the parameters needed for the design of a bench scale system for REE recovery. The ultimate project outcome will be the design for an optimized, closed loop process to economically recovery REEs such that the process may be demonstrated at the bench scale in a Phase 2 project. Project Description: The project will encompass evaluation of the ADP technology for the economic recovery of REEs from coal and coal ash. The ADP was originally designed and demonstrated for the U.S. Army to facilitate demilitarization of cast-cured munitions via acid digestion in a closed-loop process. Proof of concept testing has been conducted on a sample of Ohio-based Middle Kittanning coal and has demonstrated the feasibility of recovering REEs using the ADP technology. In AOI 1, Ohio coal sources with the potential to provide a consistent source of rare earth element concentrations above 300 parts per million will be identified. Coal sample inventories from West Virginia and Pennsylvania will also be assessed for purposes of comparison. Three methods of preparing the coal ash will be evaluated for their potential to enhance the technical feasibility and economics of REE recovery. Three sources of coal ash are targeted for evaluation of the economics of REE recovery in this project: (1) coal ash from power generation stations, to include fly ash and/or bottom ash, (2) ash generated in a lower temperature ashing process, and (3) ash residual from Battelle’s coal liquefaction process. Making use of residual ash from coal liquefaction processes directly leverages work currently being conducted by Battelle for DOE NETL in response to DE-FOA-0000981 entitled “Greenhouse Gas Emissions Reductions Research and Development Leading to Cost-Competitive Coal-to-Liquids Based Jet Fuel Production.” Using the sample characterization results and regional information regarding REE concentration, availability and cost, a TEA will be developed. The previously generated laboratory testing results for leaching and REE recovery via the ADP will be used to perform the TEA, along with common engineering assumptions for scale up of equipment and labor costs. Finally, upon validation of the economic feasibility of the process by the TEA, limited laboratory testing will be performed to support the design of a bench scale system. In a future project phase, it is envisioned that the bench scale system will be constructed and operated to prove the process on a continuous basis.« less

  18. Protocol and standard operating procedures for common use in a worldwide multicenter study on reference values.

    PubMed

    Ozarda, Yesim; Ichihara, Kiyoshi; Barth, Julian H; Klee, George

    2013-05-01

    The reference intervals (RIs) given in laboratory reports have an important role in aiding clinicians in interpreting test results in reference to values of healthy populations. In this report, we present a proposed protocol and standard operating procedures (SOPs) for common use in conducting multicenter RI studies on a national or international scale. The protocols and consensus on their contents were refined through discussions in recent C-RIDL meetings. The protocol describes in detail (1) the scheme and organization of the study, (2) the target population, inclusion/exclusion criteria, ethnicity, and sample size, (3) health status questionnaire, (4) target analytes, (5) blood collection, (6) sample processing and storage, (7) assays, (8) cross-check testing, (9) ethics, (10) data analyses, and (11) reporting of results. In addition, the protocol proposes the common measurement of a panel of sera when no standard materials exist for harmonization of test results. It also describes the requirements of the central laboratory, including the method of cross-check testing between the central laboratory of each country and local laboratories. This protocol and the SOPs remain largely exploratory and may require a reevaluation from the practical point of view after their implementation in the ongoing worldwide study. The paper is mainly intended to be a basis for discussion in the scientific community.

  19. Sorption and diffusion of selenium oxyanions in granitic rock

    NASA Astrophysics Data System (ADS)

    Ikonen, Jussi; Voutilainen, Mikko; Söderlund, Mervi; Jokelainen, Lalli; Siitari-Kauppi, Marja; Martin, Andrew

    2016-09-01

    The processes controlling diffusion and sorption of radionuclides have been studied extensively in the laboratory, whereas, only a few in-situ experiments have been carried out in order to study in-situ diffusion over the long-term (several years). This is largely due to the fact that in-situ experiments are typically time consuming and cost intensive, and it is commonly accepted that laboratory scale tests are well-established approaches to characterizing the properties of geological media. In order to assess the relevance of laboratory experiments, the Swiss National Cooperative for Disposal of Radioactive Waste (Nagra) have been conducting extensive experiments in the Underground Rock Laboratory (URL) at the Grimsel Test Site (GTS) in order to study radionuclide transport and retention in-situ. One of the elements used in these experiments is non-radioactive selenium, as an analog for the radiotoxic isotope Se-79, which is present in radioactive waste. In this work, two laboratory through-diffusion experiments using selenium as a tracer were carried out in block (decimeter) scale rock specimens to support one of the ongoing radionuclide transport and retention in-situ experiment at the GTS mentioned above. The though-diffusion tests of selenium were performed under atmospheric conditions in both Kuru grey granite (KGG) and Grimsel granodiorite (GG). The decrease of selenium concentration in an inlet hole drilled into each of the rock samples and the breakthrough of selenium into sampling holes drilled around the inlet were analyzed using Inductively Coupled Plasma Mass Spectrometry (ICP-MS). The effective diffusion (De) and distribution coefficients (Kd) of selenium were then determined from the changes of selenium concentration in the inlet and sampling holes using a Time-Domain Diffusion (TDD) simulations. In addition, Kd of selenium was measured by batch sorption experiments as a function of pH and Se concentration in atmospheric conditions and nitrogen atmosphere. The speciation of selenium was studied by HPLC-ICP-MS in simulated ground waters of each of the rock types. The Kd of selenium was found to be in the range of (6.2-7.0 ± 2.0) × 10- 3 m3/kg in crushed rock whereas the Kd obtained from block scale through diffusion experiment varied between (1.5 ± 0.3) × 10- 3 m3/kg and (1.0 ± 0.6) × 10- 4 m3/kg. The De of selenium was significantly higher for GG; De = (2.5 ± 1.5) × 10- 12 m2/s than for KGG; De = (7 ± 2) × 10- 13 m2/s due to the higher permeability of GG compared with KGG.

  20. Sorption and diffusion of selenium oxyanions in granitic rock.

    PubMed

    Ikonen, Jussi; Voutilainen, Mikko; Söderlund, Mervi; Jokelainen, Lalli; Siitari-Kauppi, Marja; Martin, Andrew

    2016-09-01

    The processes controlling diffusion and sorption of radionuclides have been studied extensively in the laboratory, whereas, only a few in-situ experiments have been carried out in order to study in-situ diffusion over the long-term (several years). This is largely due to the fact that in-situ experiments are typically time consuming and cost intensive, and it is commonly accepted that laboratory scale tests are well-established approaches to characterizing the properties of geological media. In order to assess the relevance of laboratory experiments, the Swiss National Cooperative for Disposal of Radioactive Waste (Nagra) have been conducting extensive experiments in the Underground Rock Laboratory (URL) at the Grimsel Test Site (GTS) in order to study radionuclide transport and retention in-situ. One of the elements used in these experiments is non-radioactive selenium, as an analog for the radiotoxic isotope Se-79, which is present in radioactive waste. In this work, two laboratory through-diffusion experiments using selenium as a tracer were carried out in block (decimeter) scale rock specimens to support one of the ongoing radionuclide transport and retention in-situ experiment at the GTS mentioned above. The though-diffusion tests of selenium were performed under atmospheric conditions in both Kuru grey granite (KGG) and Grimsel granodiorite (GG). The decrease of selenium concentration in an inlet hole drilled into each of the rock samples and the breakthrough of selenium into sampling holes drilled around the inlet were analyzed using Inductively Coupled Plasma Mass Spectrometry (ICP-MS). The effective diffusion (De) and distribution coefficients (Kd) of selenium were then determined from the changes of selenium concentration in the inlet and sampling holes using a Time-Domain Diffusion (TDD) simulations. In addition, Kd of selenium was measured by batch sorption experiments as a function of pH and Se concentration in atmospheric conditions and nitrogen atmosphere. The speciation of selenium was studied by HPLC-ICP-MS in simulated ground waters of each of the rock types. The Kd of selenium was found to be in the range of (6.2-7.0±2.0)×10(-3)m(3)/kg in crushed rock whereas the Kd obtained from block scale through diffusion experiment varied between (1.5±0.3)×10(-3)m(3)/kg and (1.0±0.6)×10(-4)m(3)/kg. The De of selenium was significantly higher for GG; De=(2.5±1.5)×10(-12)m(2)/s than for KGG; De=(7±2)×10(-13)m(2)/s due to the higher permeability of GG compared with KGG. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Extraction of mercury from groundwater using immobilized algae.

    PubMed

    Barkley, N P

    1991-10-01

    Bio-Recovery Systems, Inc. conducted a project under the Emerging Technology portion of the United States Environmental Protection Agency's (EPAs) Superfund Innovative Technology Evaluation (SITE) Program to evaluate the ability of immobilized algae to adsorb mercury from contaminated groundwater in laboratory studies and pilot-scale field tests. Algal biomass was incorporated in a permeable polymeric matrix. The product, AlgaSORB, packed into adsorption columns, exhibited excellent flow characteristics, and functioned as a "biological" ion exchange resin. A sequence of eleven laboratory tests demonstrated the ability of this product to adsorb mercury from groundwater that contained high levels of total dissolved solids and hard water components. However, use of a single AlgaSORB preparation yielded nonrepeatable results with samples collected at different times of the year. The strategy of sequentially extracting the groundwater through two columns containing different preparations of AlgaSORB was developed and proved successful in laboratory and pilot-scale field tests. Field test results indicate that AlgaSORB could be economically competitive with ion exchange resins for removal of mercury, with the advantage that hardness and other dissolved solids do not appear to compete with heavy metals for binding capacity.

  2. A novel multiplex poliovirus binding inhibition assay applicable for large serosurveillance and vaccine studies, without the use of live poliovirus.

    PubMed

    Schepp, Rutger M; Berbers, Guy A M; Ferreira, José A; Reimerink, Johan H; van der Klis, Fiona R

    2017-03-01

    Large-scale serosurveillance or vaccine studies for poliovirus using the "gold standard" WHO neutralisation test (NT) are very laborious and time consuming. With the polio eradication at hand and with the removal of live attenuated Sabin strains from the oral poliovirus vaccine (OPV), starting with type 2 (as of April 2016), laboratories will need to conform to much more stringent laboratory biosafety regulations when handling live poliovirus strains. In this study, a poliovirus binding inhibition multiplex immunoassay (polio MIA) using inactivated poliovirus vaccine (IPV-Salk) was developed for simultaneous quantification of serum antibodies directed to all three poliovirus types. Our assay shows a good correlation with the NT and an excellent correlation with the ELISA-based binding inhibition assay (POBI). The assay is highly type-specific and reproducible. Additionally, serum sample throughput increases about fivefold relative to NT and POBI and the amount of serum needed is reduced by more than 90%. In conclusion, the polio MIA can be used as a safe and high throughput application, especially for large-scale surveillance and vaccine studies, reducing laboratory time and serum amounts needed. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  3. Web-based scoring of the dicentric assay, a collaborative biodosimetric scoring strategy for population triage in large scale radiation accidents.

    PubMed

    Romm, H; Ainsbury, E; Bajinskis, A; Barnard, S; Barquinero, J F; Barrios, L; Beinke, C; Puig-Casanovas, R; Deperas-Kaminska, M; Gregoire, E; Oestreicher, U; Lindholm, C; Moquet, J; Rothkamm, K; Sommer, S; Thierens, H; Vral, A; Vandersickel, V; Wojcik, A

    2014-05-01

    In the case of a large scale radiation accident high throughput methods of biological dosimetry for population triage are needed to identify individuals requiring clinical treatment. The dicentric assay performed in web-based scoring mode may be a very suitable technique. Within the MULTIBIODOSE EU FP7 project a network is being established of 8 laboratories with expertise in dose estimations based on the dicentric assay. Here, the manual dicentric assay was tested in a web-based scoring mode. More than 23,000 high resolution images of metaphase spreads (only first mitosis) were captured by four laboratories and established as image galleries on the internet (cloud). The galleries included images of a complete dose effect curve (0-5.0 Gy) and three types of irradiation scenarios simulating acute whole body, partial body and protracted exposure. The blood samples had been irradiated in vitro with gamma rays at the University of Ghent, Belgium. Two laboratories provided image galleries from Fluorescence plus Giemsa stained slides (3 h colcemid) and the image galleries from the other two laboratories contained images from Giemsa stained preparations (24 h colcemid). Each of the 8 participating laboratories analysed 3 dose points of the dose effect curve (scoring 100 cells for each point) and 3 unknown dose points (50 cells) for each of the 3 simulated irradiation scenarios. At first all analyses were performed in a QuickScan Mode without scoring individual chromosomes, followed by conventional scoring (only complete cells, 46 centromeres). The calibration curves obtained using these two scoring methods were very similar, with no significant difference in the linear-quadratic curve coefficients. Analysis of variance showed a significant effect of dose on the yield of dicentrics, but no significant effect of the laboratories, different methods of slide preparation or different incubation times used for colcemid. The results obtained to date within the MULTIBIODOSE project by a network of 8 collaborating laboratories throughout Europe are very promising. The dicentric assay in the web based scoring mode as a high throughput scoring strategy is a useful application for biodosimetry in the case of a large scale radiation accident.

  4. Time-resolved acoustic emission tomography in the laboratory: tracking localised damage in rocks

    NASA Astrophysics Data System (ADS)

    Brantut, N.

    2017-12-01

    Over the past three decades, there has been tremendous technological developments of laboratory equipment and studies using acoustic emission and ultrasonic monitoring of rock samples during deformation. Using relatively standard seismological techniques, acoustic emissions can be detected, located in space and time, and source mechanisms can be obtained. In parallel, ultrasonic velocities can be measured routinely using standard pulse-receiver techniques.Despite these major developments, current acoustic emission and ultrasonic monitoring systems are typically used separately, and the poor spatial coverage of acoustic transducers precludes performing active 3D tomography in typical laboratory settings.Here, I present an algorithm and software package that uses both passive acoustic emission data and active ultrasonic measurements to determine acoustic emission locations together with the 3D, anisotropic P-wave structure of rock samples during deformation. The technique is analogous to local earthquake tomography, but tailored to the specificities of small scale laboratory tests. The fast marching method is employed to compute the forward problem. The acoustic emission locations and the anisotropic P-wave field are jointly inverted using the Quasi-Newton method.The method is used to track the propagation of compaction bands in a porous sandstone deformed in the ductile, cataclastic flow regime under triaxial stress conditions. Near the yield point, a compaction front forms at one end of the sample, and slowly progresses towards the other end. The front is illuminated by clusters of Acoustic Emissions, and leaves behind a heavily damaged material where the P-wave speed has dropped by up to 20%.The technique opens new possibilities to track in-situ strain localisation and damage around laboratory faults, and preliminary results on quasi-static rupture in granite will be presented.

  5. Laying the groundwork for NEON's continental-scale ecological research

    NASA Astrophysics Data System (ADS)

    Dethloff, G.; Denslow, M.

    2013-12-01

    The National Ecological Observatory Network (NEON) is designed to examine a suite of ecological issues. Field-collected data from 96 terrestrial and aquatic sites across the U.S. will be combined with remotely sensed data and existing continental-scale data sets. Field collections will include a range of physical and biological types, including soil, sediment, surface water, groundwater, precipitation, plants, animals, insects, and microbes as well as biological sub-samples such as leaf material, blood and tissue samples, and DNA extracts. Initial data analyses and identifications of approximately 175,000 samples per year will occur at numerous external laboratories when all sites are fully staffed in 2017. Additionally, NEON will archive biotic and abiotic specimens at collections facilities where they will be curated and available for additional analyses by the scientific community. The number of archived specimens is currently estimated to exceed 130,000 per year by 2017. We will detail how NEON is addressing the complexities and challenges around this set of analyses and specimens and how the resulting high-quality data can impact ecological understanding. The raw data returned from external laboratories that is quality checked and served by NEON will be the foundation for many NEON data products. For example, sequence-quality nucleic acids extracted from surface waters, benthic biofilms, and soil samples will be building blocks for data products on microbial diversity. The raw sequence data will also be available for uses such as evolutionary investigations, and the extracts will be archived so others can acquire them for additional research. Currently, NEON is establishing contracts for the analysis and archiving of field-collected samples through 2017. During this period, NEON will gather information on the progress and success of this large-scale effort in order to determine the most effective course to pursue with external facilities. Two areas that NEON already knows to evaluate are the need for geographic expertise in taxonomic identifications and the capacity necessary to handle the volume of samples. NEON is also addressing challenges associated with external entities and the logistics of sample movement, data formatting, data ingestion, and reporting. For example, NEON is considering tools, such as web APIs, which could allow efficient transfer of data from external facilities. Having a standard format in place for that data will be critical to transfer success and quality assessment. NEON is also working on the implementation of quality control measures for diverse analytical and taxonomic processes across laboratories, and is developing an external audit process. Additionally, given NEON's open access approach, the Network is focused on selecting a sample identification protocol that aids in tracking samples with more involved analytical needs and also allows maximum utility for the scientific community. Given the complex nature and breadth of the project, NEON will be developing novel sample management systems as well as metadata schemas. These efforts insure integrity and quality from field to external facility to archive for each sample taken, providing high-quality data now and confidence in future research stemming from raw data generated by NEON and its collection specimens.

  6. Imaging the Subsurface of the Thuringian Basin (Germany) on Different Spatial Scales

    NASA Astrophysics Data System (ADS)

    Goepel, A.; Krause, M.; Methe, P.; Kukowski, N.

    2014-12-01

    Understanding the coupled dynamics of near surface and deep fluid flow patterns is essential to characterize the properties of sedimentary basins, to identify the processes of compaction, diagenesis, and transport of mass and energy. The multidisciplinary project INFLUINS (Integrated FLUid dynamics IN Sedimentary basins) aims for investigating the behavior of fluids in the Thuringian Basin, a small intra-continental sedimentary basin in Germany, at different spatial scales, ranging from the pore scale to the extent of the entire basin. As hydraulic properties often significantly vary with spatial scales, e.g. seismic data using different frequencies are required to gain information about the spatial variability of elastic and hydraulic subsurface properties. For the Thuringian Basin, we use seismic and borehole data acquired in the framework of INFLUINS. Basin-wide structural imaging data are available from 2D reflection seismic profiles as well as 2.5D and 3D seismic travel time tomography. Further, core material from a 1,179 m deep drill hole completed in 2013 is available for laboratory seismic experiments on mm- to cm-scale. The data are complemented with logging data along the entire drill hole. This campaign yielded e.g. sonic and density logs allowing the estimation of in-situ P-velocity and acoustic impedance with a spatial resolution on the cm-scale and provides improved information about petrologic and stratigraphic variability at different scales. Joint interpretation of basin scale structural and elastic properties data with laboratory scale data from ultrasound experiments using core samples enables a detailed and realistic imaging of the subsurface properties on different spatial scales. Combining seismic travel time tomography with stratigraphic interpretation provides useful information of variations in the elastic properties for certain geological units and therefore gives indications for changes in hydraulic properties.

  7. Passive seismic monitoring of natural and induced earthquakes: case studies, future directions and socio-economic relevance

    USGS Publications Warehouse

    Bohnhoff, Marco; Dresen, Georg; Ellsworth, William L.; Ito, Hisao; Cloetingh, Sierd; Negendank, Jörg

    2010-01-01

    An important discovery in crustal mechanics has been that the Earth’s crust is commonly stressed close to failure, even in tectonically quiet areas. As a result, small natural or man-made perturbations to the local stress field may trigger earthquakes. To understand these processes, Passive Seismic Monitoring (PSM) with seismometer arrays is a widely used technique that has been successfully applied to study seismicity at different magnitude levels ranging from acoustic emissions generated in the laboratory under controlled conditions, to seismicity induced by hydraulic stimulations in geological reservoirs, and up to great earthquakes occurring along plate boundaries. In all these environments the appropriate deployment of seismic sensors, i.e., directly on the rock sample, at the earth’s surface or in boreholes close to the seismic sources allows for the detection and location of brittle failure processes at sufficiently low magnitude-detection threshold and with adequate spatial resolution for further analysis. One principal aim is to develop an improved understanding of the physical processes occurring at the seismic source and their relationship to the host geologic environment. In this paper we review selected case studies and future directions of PSM efforts across a wide range of scales and environments. These include induced failure within small rock samples, hydrocarbon reservoirs, and natural seismicity at convergent and transform plate boundaries. Each example represents a milestone with regard to bridging the gap between laboratory-scale experiments under controlled boundary conditions and large-scale field studies. The common motivation for all studies is to refine the understanding of how earthquakes nucleate, how they proceed and how they interact in space and time. This is of special relevance at the larger end of the magnitude scale, i.e., for large devastating earthquakes due to their severe socio-economic impact.

  8. Coal Technology Program progress report, March 1976

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    Shakedown tests of the bench-scale hydrocarbonization system were successfully completed. Wyodak coal was fed to the reactor at a rate of 9.9 lb/hr where it was hydrocarbonized at 1050/sup 0/F under 20-atm hydrogen pressure. Laboratory results including settling tests, bench-scale settling tests, and sample ageing tests were continued. Two of ten compounds tested with the laboratory-scale apparatus were effective in increasing settling rates of solids in Solvent Refined Coal unfiltered oil, but bench-scale tests failed to show any improvements in the settling rate over the untreated SRC-UFO. Analytical chemistry efforts involved the removal and concentration of organic components in by-productmore » waters from fossil fuel conversion processes. A sephadex gel is being used to achieve hydrophilic-lipophilic separations in organic mixtures as a step in the analysis of fossil fuel related materials. Engineering Evaluations of the Synthiol and Hydrocarbonization Processes continued with the Synthiol process flow diagrams, heat and material balances, and utilities requirements being completed. Inspection techniques were developed for wear- and process-resistant coatings. Orders were placed for the Incoloy 800 tubing and a smaller quantity of Inconel 600 tubing for the tube matrix in the coal-fueled MIUS fluidized bed. An engineering feasibility review of General Atomic's proposal to ERDA for a bench-scale test program on thermochemical water splitting for hydrogen production was completed. (auth)« less

  9. The Children's Social Understanding Scale: construction and validation of a parent-report measure for assessing individual differences in children's theories of mind.

    PubMed

    Tahiroglu, Deniz; Moses, Louis J; Carlson, Stephanie M; Mahy, Caitlin E V; Olofson, Eric L; Sabbagh, Mark A

    2014-11-01

    Children's theory of mind (ToM) is typically measured with laboratory assessments of performance. Although these measures have generated a wealth of informative data concerning developmental progressions in ToM, they may be less useful as the sole source of information about individual differences in ToM and their relation to other facets of development. In the current research, we aimed to expand the repertoire of methods available for measuring ToM by developing and validating a parent-report ToM measure: the Children's Social Understanding Scale (CSUS). We present 3 studies assessing the psychometric properties of the CSUS. Study 1 describes item analysis, internal consistency, test-retest reliability, and relation of the scale to children's performance on laboratory ToM tasks. Study 2 presents cross-validation data for the scale in a different sample of preschool children with a different set of ToM tasks. Study 3 presents further validation data for the scale with a slightly older age group and a more advanced ToM task, while controlling for several other relevant cognitive abilities. The findings indicate that the CSUS is a reliable and valid measure of individual differences in children's ToM that may be of great value as a complement to standard ToM tasks in many different research contexts. (PsycINFO Database Record (c) 2014 APA, all rights reserved).

  10. Comparing field investigations with laboratory models to predict landfill leachate emissions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fellner, Johann; Doeberl, Gernot; Allgaier, Gerhard

    2009-06-15

    Investigations into laboratory reactors and landfills are used for simulating and predicting emissions from municipal solid waste landfills. We examined water flow and solute transport through the same waste body for different volumetric scales (laboratory experiment: 0.08 m{sup 3}, landfill: 80,000 m{sup 3}), and assessed the differences in water flow and leachate emissions of chloride, total organic carbon and Kjeldahl nitrogen. The results indicate that, due to preferential pathways, the flow of water in field-scale landfills is less uniform than in laboratory reactors. Based on tracer experiments, it can be discerned that in laboratory-scale experiments around 40% of pore watermore » participates in advective solute transport, whereas this fraction amounts to less than 0.2% in the investigated full-scale landfill. Consequences of the difference in water flow and moisture distribution are: (1) leachate emissions from full-scale landfills decrease faster than predicted by laboratory experiments, and (2) the stock of materials remaining in the landfill body, and thus the long-term emission potential, is likely to be underestimated by laboratory landfill simulations.« less

  11. Interlaboratory comparison of extraction efficiency of pesticides from surface and laboratory water using solid-phase extraction disks.

    PubMed

    Senseman, Scott A; Mueller, Thomas C; Riley, Melissa B; Wauchope, R Don; Clegg, Chris; Young, Roddy W; Southwick, Lloyd M; Moye, H Anson; Dumas, Jose A; Mersie, Wondi; Mattice, John D; Leidy, Ross B

    2003-06-18

    A continuation of an earlier interlaboratory comparison was conducted (1) to assess solid-phase extraction (SPE) using Empore disks to extract atrazine, bromacil, metolachlor, and chlorpyrifos from various water sources accompanied by different sample shipping and quantitative techniques and (2) to compare quantitative results of individual laboratories with results of one common laboratory. Three replicates of a composite surface water (SW) sample were fortified with the analytes along with three replicates of deionized water (DW). A nonfortified DW sample and a nonfortified SW sample were also extracted. All samples were extracted using Empore C(18) disks. After extraction, part of the samples were eluted and analyzed in-house. Duplicate samples were evaporated in a 2-mL vial, shipped dry to a central laboratory (SDC), redissolved, and analyzed. Overall, samples analyzed in-house had higher recoveries than SDC samples. Laboratory x analysis type and laboratory x water source interactions were significant for all four compounds. Seven laboratories participated in this interlaboratory comparison program. No differences in atrazine recoveries were observed from in-house samples analyzed by laboratories A, B, D, and G compared with the recovery of SDC samples. In-house atrazine recoveries from laboratories C and F were higher when compared with recovery from SDC samples. However, laboratory E had lower recoveries from in-house samples compared with SDC samples. For each laboratory, lower recoveries were observed for chlorpyrifos from the SDC samples compared with samples analyzed in-house. Bromacil recovery was <65% at two of the seven laboratories in the study. Bromacil recoveries for the remaining laboratories were >75%. Three laboratories showed no differences in metolachlor recovery; two laboratories had higher recoveries for samples analyzed in-house, and two other laboratories showed higher metolachlor recovery for SDC samples. Laboratory G had a higher recovery in SW for all four compounds compared with DW. Other laboratories that had significant differences in pesticide recovery between the two water sources showed higher recovery in DW than in the SW regardless of the compound. In comparison to earlier work, recovery of these compounds using SPE disks as a temporary storage matrix may be more effective than shipping dried samples in a vial. Problems with analytes such as chlorpyrifos are unavoidable, and it should not be assumed that an extraction procedure using SPE disks will be adequate for all compounds and transferrable across all chromatographic conditions.

  12. Monitoring Local Changes in Granite Rock Under Biaxial Test: A Spatiotemporal Imaging Application With Diffuse Waves

    NASA Astrophysics Data System (ADS)

    Xie, Fan; Ren, Yaqiong; Zhou, Yongsheng; Larose, Eric; Baillet, Laurent

    2018-03-01

    Diffuse acoustic or seismic waves are highly sensitive to detect changes of mechanical properties in heterogeneous geological materials. In particular, thanks to acoustoelasticity, we can quantify stress changes by tracking acoustic or seismic relative velocity changes in the material at test. In this paper, we report on a small-scale laboratory application of an innovative time-lapse tomography technique named Locadiff to image spatiotemporal mechanical changes on a granite sample under biaxial loading, using diffuse waves at ultrasonic frequencies (300 kHz to 900 kHz). We demonstrate the ability of the method to image reversible stress evolution and deformation process, together with the development of reversible and irreversible localized microdamage in the specimen at an early stage. Using full-field infrared thermography, we visualize stress-induced temperature changes and validate stress images obtained from diffuse ultrasound. We demonstrate that the inversion with a good resolution can be achieved with only a limited number of receivers distributed around a single source, all located at the free surface of the specimen. This small-scale experiment is a proof of concept for frictional earthquake-like failure (e.g., stick-slip) research at laboratory scale as well as large-scale seismic applications, potentially including active fault monitoring.

  13. Farm Deployable Microbial Bioreactor for Fuel Ethanol Production

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Okeke, Benedict

    Research was conducted to develop a farm and field deployable microbial bioreactor for bioethanol production from biomass. Experiments were conducted to select the most efficient microorganisms for conversion of plant fiber to sugars for fermentation to ethanol. Mixtures of biomass and surface soil samples were collected from selected sites in Alabama black belt counties (Macon, Sumter, Choctaw, Dallas, Montgomery, Lowndes) and other areas within the state of Alabama. Experiments were conducted to determine the effects of culture parameters on key biomass saccharifying enzymes (cellulase, beta-glucosidase, xylanase and beta-xylosidase). A wide-scale sampling of locally-grown fruits in Central Alabama was embarked tomore » isolate potential xylose fermenting microorganisms. Yeast isolates were evaluated for xylose fermentation. Selected microorganisms were characterized by DNA based methods. Factors affecting enzyme production and biomass saccharification were examined and optimized in the laboratory. Methods of biomass pretreatment were compared. Co-production of amylolytic enzymes with celluloytic-xylanolytic enzymes was evaluated; and co-saccharification of a combination of biomass, and starch-rich materials was examined. Simultaneous saccharification and fermentation with and without pre-saccharifcation was studied. Whole culture broth and filtered culture broth simultaneous saccahrifcation and fermentation were compared. A bioreactor system was designed and constructed to employ laboratory results for scale up of biomass saccharification.« less

  14. Mars Science Laboratory Engineering Cameras

    NASA Technical Reports Server (NTRS)

    Maki, Justin N.; Thiessen, David L.; Pourangi, Ali M.; Kobzeff, Peter A.; Lee, Steven W.; Dingizian, Arsham; Schwochert, Mark A.

    2012-01-01

    NASA's Mars Science Laboratory (MSL) Rover, which launched to Mars in 2011, is equipped with a set of 12 engineering cameras. These cameras are build-to-print copies of the Mars Exploration Rover (MER) cameras, which were sent to Mars in 2003. The engineering cameras weigh less than 300 grams each and use less than 3 W of power. Images returned from the engineering cameras are used to navigate the rover on the Martian surface, deploy the rover robotic arm, and ingest samples into the rover sample processing system. The navigation cameras (Navcams) are mounted to a pan/tilt mast and have a 45-degree square field of view (FOV) with a pixel scale of 0.82 mrad/pixel. The hazard avoidance cameras (Haz - cams) are body-mounted to the rover chassis in the front and rear of the vehicle and have a 124-degree square FOV with a pixel scale of 2.1 mrad/pixel. All of the cameras utilize a frame-transfer CCD (charge-coupled device) with a 1024x1024 imaging region and red/near IR bandpass filters centered at 650 nm. The MSL engineering cameras are grouped into two sets of six: one set of cameras is connected to rover computer A and the other set is connected to rover computer B. The MSL rover carries 8 Hazcams and 4 Navcams.

  15. Thermal hazard assessment of AN and AN-based explosives.

    PubMed

    Turcotte, R; Lightfoot, P D; Fouchard, R; Jones, D E G

    2003-07-04

    Ammonium nitrate (AN) is an essential ingredient in most fertilizers. It is also widely used in the commercial explosives industry. In this latter application, it is mostly mixed with fuel oil to form the most popular commercial explosive: ANFO. In both the fertilizer and the explosive industry, aqueous AN solutions (ANS) of various concentrations are processed. These solutions also form the basis of ammonium nitrate emulsion explosives (also called ammonium nitrate emulsions or ANE), which are produced either in bulk or in packaged form. For all these AN-based products, quantities of the order of 20,000kg are being manufactured, transported, stored, and processed at elevated temperatures and/or elevated pressures. Correspondingly, major accidents involving overheating of large quantities of these products have happened in several of these operations. In comparison, convenient laboratory quantities to investigate thermal decomposition properties are generally less than 1kg. As a result, in order to provide information applicable to real-life situations, any laboratory study must use techniques that minimize heat losses from the samples to their environment. In the present study, two laboratory-scale calorimeters providing an adiabatic environment were used: an accelerating rate calorimeter (ARC) and an adiabatic Dewar calorimeter (ADC). Experiments were performed on pure AN, ANFO, various ANS systems, and typical bulk and packaged ANE systems. The effects of sample mass, atmosphere, and formulation on the resulting onset temperatures were studied. A comparison of the results from the two techniques is provided and a proposed method to extrapolate these results to large-scale inventories is examined.

  16. Perfectionism and Polysomnography-Determined Markers of Poor Sleep

    PubMed Central

    Johann, Anna F.; Hertenstein, Elisabeth; Kyle, Simon D.; Baglioni, Chiara; Feige, Bernd; Nissen, Christoph; Riemann, Dieter; Spiegelhalder, Kai

    2017-01-01

    Study Objectives: Perfectionism has been suggested to represent a predisposing factor for poor sleep. However, previous studies have relied on self-reported measures. The association between perfectionism and poor sleep measured by polysomnography (PSG) warrants further investigation. Methods: The current retrospective exploratory study used the Frost Multidimensional Perfectionism Scale and PSG in an unselected sample of 334 consecutive sleep laboratory patients (140 males, 194 females, 44.6 ± 15.9 years). Data were analyzed using linear regression analyses. Results: High levels of perfectionism were associated with PSG-determined markers of poor sleep in the first sleep laboratory night. The total Frost Multidimensional Perfectionism Scale score was significantly associated with the number of nocturnal awakenings in the first sleep laboratory night. The subscales “concern over mistakes” and “personal standards” of perfectionism were significantly associated with markers of poor sleep. In contrast, there were only a few associations between perfectionism and PSG variables of the second sleep laboratory night. Conclusions: This pattern of results suggests that high levels of perfectionism may predispose individuals to sleep disturbances in the context of acute stressors. Thus, the influence of perfectionism on poor sleep should be further investigated to improve treatment. Citation: Johann AF, Hertenstein E, Kyle SD, Baglioni C, Feige B, Nissen C, Riemann D, Spiegelhalder K. Perfectionism and polysomnography-determined markers of poor sleep. J Clin Sleep Med. 2017;13(11):1319–1326. PMID:28992830

  17. The case for planetary sample return missions. 2. History of Mars.

    PubMed

    Gooding, J L; Carr, M H; McKay, C P

    1989-08-01

    Principal science goals for exploration of Mars are to establish the chemical, isotopic, and physical state of Martian material, the nature of major surface-forming processes and their time scales, and the past and present biological potential of the planet. Many of those goals can only be met by detailed analyses of atmospheric gases and carefully selected samples of fresh rocks, weathered rocks, soils, sediments, and ices. The high-fidelity mineral separations, complex chemical treatments, and ultrasensitive instrument systems required for key measurements, as well as the need to adapt analytical strategies to unanticipated results, point to Earth-based laboratory analyses on returned Martian samples as the best means for meeting the stated objectives.

  18. Numerical Investigation of Earthquake Nucleation on a Laboratory-Scale Heterogeneous Fault with Rate-and-State Friction

    NASA Astrophysics Data System (ADS)

    Higgins, N.; Lapusta, N.

    2014-12-01

    Many large earthquakes on natural faults are preceded by smaller events, often termed foreshocks, that occur close in time and space to the larger event that follows. Understanding the origin of such events is important for understanding earthquake physics. Unique laboratory experiments of earthquake nucleation in a meter-scale slab of granite (McLaskey and Kilgore, 2013; McLaskey et al., 2014) demonstrate that sample-scale nucleation processes are also accompanied by much smaller seismic events. One potential explanation for these foreshocks is that they occur on small asperities - or bumps - on the fault interface, which may also be the locations of smaller critical nucleation size. We explore this possibility through 3D numerical simulations of a heterogeneous 2D fault embedded in a homogeneous elastic half-space, in an attempt to qualitatively reproduce the laboratory observations of foreshocks. In our model, the simulated fault interface is governed by rate-and-state friction with laboratory-relevant frictional properties, fault loading, and fault size. To create favorable locations for foreshocks, the fault surface heterogeneity is represented as patches of increased normal stress, decreased characteristic slip distance L, or both. Our simulation results indicate that one can create a rate-and-state model of the experimental observations. Models with a combination of higher normal stress and lower L at the patches are closest to matching the laboratory observations of foreshocks in moment magnitude, source size, and stress drop. In particular, we find that, when the local compression is increased, foreshocks can occur on patches that are smaller than theoretical critical nucleation size estimates. The additional inclusion of lower L for these patches helps to keep stress drops within the range observed in experiments, and is compatible with the asperity model of foreshock sources, since one would expect more compressed spots to be smoother (and hence have lower L). In this heterogeneous rate-and-state fault model, the foreshocks interact with each other and with the overall nucleation process through their postseismic slip. The interplay amongst foreshocks, and between foreshocks and the larger-scale nucleation process, is a topic of our future work.

  19. EFFECTS OF LARVAL STOCKING DENSITY ON LABORATORY-SCALE AND COMMERICAL-SCALE PRODUCTION OF SUMMER FLOUNDER, PARALICHTHYS DENTATUS

    EPA Science Inventory

    Three experiments investigating larval stocking densities of summer flounder from hatch to metamorphosis, Paralichthys dentatus, were conducted at laboratory-scale (75-L aquaria) and at commercial scale (1,000-L tanks). Experiments 1 and 2 at commercial scale tested the densities...

  20. Questionnaire and laboratory measures of eating behavior: Associations with energy intake and BMI in a community sample of working adults

    PubMed Central

    French, Simone A; Mitchell, Nathan R; Wolfson, Julian; Finlayson, Graham; Blundell, John E; Jeffery, Robert W

    2013-01-01

    Purpose The present research compared a self-report measure of usual eating behaviors with two laboratory-based behavioral measures of food reward and food preference. Methods Eating behaviors were measured among 233 working adults. A self-report measure was the Three Factor Eating Questionnaire (TFEQ) Restraint, Disinhibition and Hunger subscales. Laboratory measures were the (RVF) and Explicit Liking (EL) and Implicit Wanting (IW) for high fat food. Outcome measures were body mass index (BMI), and energy intake measured using three 24-hour dietary recalls. Results Significant bivariate associations were observed between each of the eating behavior measures and energy intake, but only Disinhibition and Hunger were associated with BMI. Multiple regression results showed RVF and EL and IW predicted energy intake independent of the TFEQ scales but did not predict BMI. Conclusion Laboratory and self-report measures capture unique aspects of individual differences in eating behaviors that are associated with energy intake. PMID:24096082

  1. Assessing technical performance in differential gene expression experiments with external spike-in RNA control ratio mixtures.

    PubMed

    Munro, Sarah A; Lund, Steven P; Pine, P Scott; Binder, Hans; Clevert, Djork-Arné; Conesa, Ana; Dopazo, Joaquin; Fasold, Mario; Hochreiter, Sepp; Hong, Huixiao; Jafari, Nadereh; Kreil, David P; Łabaj, Paweł P; Li, Sheng; Liao, Yang; Lin, Simon M; Meehan, Joseph; Mason, Christopher E; Santoyo-Lopez, Javier; Setterquist, Robert A; Shi, Leming; Shi, Wei; Smyth, Gordon K; Stralis-Pavese, Nancy; Su, Zhenqiang; Tong, Weida; Wang, Charles; Wang, Jian; Xu, Joshua; Ye, Zhan; Yang, Yong; Yu, Ying; Salit, Marc

    2014-09-25

    There is a critical need for standard approaches to assess, report and compare the technical performance of genome-scale differential gene expression experiments. Here we assess technical performance with a proposed standard 'dashboard' of metrics derived from analysis of external spike-in RNA control ratio mixtures. These control ratio mixtures with defined abundance ratios enable assessment of diagnostic performance of differentially expressed transcript lists, limit of detection of ratio (LODR) estimates and expression ratio variability and measurement bias. The performance metrics suite is applicable to analysis of a typical experiment, and here we also apply these metrics to evaluate technical performance among laboratories. An interlaboratory study using identical samples shared among 12 laboratories with three different measurement processes demonstrates generally consistent diagnostic power across 11 laboratories. Ratio measurement variability and bias are also comparable among laboratories for the same measurement process. We observe different biases for measurement processes using different mRNA-enrichment protocols.

  2. Laboratory-size three-dimensional x-ray microscope with Wolter type I mirror optics and an electron-impact water window x-ray source

    NASA Astrophysics Data System (ADS)

    Ohsuka, Shinji; Ohba, Akira; Onoda, Shinobu; Nakamoto, Katsuhiro; Nakano, Tomoyasu; Miyoshi, Motosuke; Soda, Keita; Hamakubo, Takao

    2014-09-01

    We constructed a laboratory-size three-dimensional water window x-ray microscope that combines wide-field transmission x-ray microscopy with tomographic reconstruction techniques, and observed bio-medical samples to evaluate its applicability to life science research fields. It consists of a condenser and an objective grazing incidence Wolter type I mirror, an electron-impact type oxygen Kα x-ray source, and a back-illuminated CCD for x-ray imaging. A spatial resolution limit of around 1.0 line pairs per micrometer was obtained for two-dimensional transmission images, and 1-μm scale three-dimensional fine structures were resolved.

  3. Laboratory-size three-dimensional x-ray microscope with Wolter type I mirror optics and an electron-impact water window x-ray source.

    PubMed

    Ohsuka, Shinji; Ohba, Akira; Onoda, Shinobu; Nakamoto, Katsuhiro; Nakano, Tomoyasu; Miyoshi, Motosuke; Soda, Keita; Hamakubo, Takao

    2014-09-01

    We constructed a laboratory-size three-dimensional water window x-ray microscope that combines wide-field transmission x-ray microscopy with tomographic reconstruction techniques, and observed bio-medical samples to evaluate its applicability to life science research fields. It consists of a condenser and an objective grazing incidence Wolter type I mirror, an electron-impact type oxygen Kα x-ray source, and a back-illuminated CCD for x-ray imaging. A spatial resolution limit of around 1.0 line pairs per micrometer was obtained for two-dimensional transmission images, and 1-μm scale three-dimensional fine structures were resolved.

  4. Pre-Analytical Components of Risk in Four Branches of Clinical Laboratory in Romania--Prospective Study.

    PubMed

    David, Remona E; Dobreanu, Minodora

    2016-01-01

    Development of quality measurement principles is a strategic point for each clinical laboratory. Preexamination process is the most critical and the most difficult to be managed. The aim of this study is to identify, quantify, and monitor the nonconformities of the pre-analytical process using quality indicators that can affect the patient's health safety in four different locations of a Romanian private clinical laboratory. The study group consisted of all the analysis requests received by the departments of biochemistry, hematology, and coagulation from January through March 2015. In order to collect the pre-analytical nonconformities, we created a "Risk Budget", using the entries from the "Evidence notebook--non-conform samples" from the above mentioned departments. The laboratory established the quality indicators by means of the risk management technique in order to identify and control the sources of errors, FMEA (Failure Modes and Effects Analyses), which had been implemented and monitored for its purposes and special needs. For the assessment of the control level over the processes, the results were transformed on the Six Sigma scale, using the Westgard calculation method and being obtained in this way the frequency with which an error may occur. (https://www.westgard. com/six-sigma-calculators.htm). The obtained results prove that the quantification and monitoring of the indicators can be a control instrument for the pre-analytic activities. The calculation of the Six Sigma value adds extra information to the study because it allows the detection of the processes which need improvement (Sigma value higher than 4 represents a well controlled process). The highest rates were observed for the hemolyzed and the lipemic samples, in the department of biochemistry and hemolyzed, insufficient sample volume, or clotted samples for the department of hematology and coagulation. Significant statistical differences between laboratories participating in the study have been recorded for these indicators. The elaborated study between the four branches of a Romanian private clinical laboratory was a challenge, and it helped in choosing strategic decisions regarding the improvement of the patient's health safety in the institution, corresponding to the accreditation requirements in accordance with ISO 15189:2013.

  5. COTHERM: Geophysical Modeling of High Enthalpy Geothermal Systems

    NASA Astrophysics Data System (ADS)

    Grab, Melchior; Maurer, Hansruedi; Greenhalgh, Stewart

    2014-05-01

    In recent years geothermal heating and electricity generation have become an attractive alternative energy resource, especially natural high enthalpy geothermal systems such as in Iceland. However, the financial risk of installing and operating geothermal power plants is still high and more needs to be known about the geothermal processes and state of the reservoir in the subsurface. A powerful tool for probing the underground system structure is provided by geophysical techniques, which are able to detect flow paths and fracture systems without drilling. It has been amply demonstrated that small-scale features can be well imaged at shallow depths, but only gross structures can be delineated for depths of several kilometers, where most high enthalpy systems are located. Therefore a major goal of our study is to improve geophysical mapping strategies by multi-method geophysical simulations and synthetic data inversions, to better resolve structures at greater depth, characterize the reservoir and monitor any changes within it. The investigation forms part of project COTHERM - COmbined hydrological, geochemical and geophysical modeling of geoTHERMal systems - in which a holistic and synergistic approach is being adopted to achieve multidisciplinary cooperation and mutual benefit. The geophysical simulations are being performed in combination with hydrothermal fluid flow modeling and chemical fluid rock interaction modeling, to provide realistic constraints on lithology, pressure, temperature and fluid conditions of the subsurface. Two sites in Iceland have been selected for the study, Krafla and Reykjanes. As a starting point for the geophysical modeling, we seek to establish petrophysical relations, connecting rock properties and reservoir conditions with geophysical parameters such as seismic wave speed, attenuation, electrical conductivity and magnetic susceptibility with a main focus on seismic properties. Therefore, we follow a comprehensive approach involving three components: (1) A literature study to find relevant, existing theoretical models, (2) laboratory determinations to confirm their validity for Icelandic rocks of interest and (3) a field campaign to obtain in-situ, shallow rock properties from seismic and resistivity tomography surveys over a fossilized and exhumed geothermal system. Theoretical models describing physical behavior for rocks with strong inhomogeneities, complex pore structure and complicated fluid-rock interaction mechanisms are often poorly constrained and require the knowledge about a wide range of parameters that are difficult to quantify. Therefore we calibrate the theoretical models by laboratory measurements on samples of rocks, forming magmatic geothermal reservoirs. Since the samples used in the laboratory are limited in size, and laboratory equipment operates at much higher frequency than the instruments used in the field, the results need to be up-scaled from the laboratory scale to field scale. This is not a simple process and entails many uncertainties.

  6. Comparison of microbiological diagnosis of urinary tract infection in young children by routine health service laboratories and a research laboratory: Diagnostic cohort study.

    PubMed

    Birnie, Kate; Hay, Alastair D; Wootton, Mandy; Howe, Robin; MacGowan, Alasdair; Whiting, Penny; Lawton, Michael; Delaney, Brendan; Downing, Harriet; Dudley, Jan; Hollingworth, William; Lisles, Catherine; Little, Paul; O'Brien, Kathryn; Pickles, Timothy; Rumsby, Kate; Thomas-Jones, Emma; Van der Voort, Judith; Waldron, Cherry-Ann; Harman, Kim; Hood, Kerenza; Butler, Christopher C; Sterne, Jonathan A C

    2017-01-01

    To compare the validity of diagnosis of urinary tract infection (UTI) through urine culture between samples processed in routine health service laboratories and those processed in a research laboratory. We conducted a prospective diagnostic cohort study in 4808 acutely ill children aged <5 years attending UK primary health care. UTI, defined as pure/predominant growth ≥105 CFU/mL of a uropathogen (the reference standard), was diagnosed at routine health service laboratories and a central research laboratory by culture of urine samples. We calculated areas under the receiver-operator curve (AUC) for UTI predicted by pre-specified symptoms, signs and dipstick test results (the "index test"), separately according to whether samples were obtained by clean catch or nappy (diaper) pads. 251 (5.2%) and 88 (1.8%) children were classified as UTI positive by health service and research laboratories respectively. Agreement between laboratories was moderate (kappa = 0.36; 95% confidence interval [CI] 0.29, 0.43), and better for clean catch (0.54; 0.45, 0.63) than nappy pad samples (0.20; 0.12, 0.28). In clean catch samples, the AUC was lower for health service laboratories (AUC = 0.75; 95% CI 0.69, 0.80) than the research laboratory (0.86; 0.79, 0.92). Values of AUC were lower in nappy pad samples (0.65 [0.61, 0.70] and 0.79 [0.70, 0.88] for health service and research laboratory positivity, respectively) than clean catch samples. The agreement of microbiological diagnosis of UTI comparing routine health service laboratories with a research laboratory was moderate for clean catch samples and poor for nappy pad samples and reliability is lower for nappy pad than for clean catch samples. Positive results from the research laboratory appear more likely to reflect real UTIs than those from routine health service laboratories, many of which (particularly from nappy pad samples) could be due to contamination. Health service laboratories should consider adopting procedures used in the research laboratory for paediatric urine samples. Primary care clinicians should try to obtain clean catch samples, even in very young children.

  7. Evaluation of malodor for automobile air conditioner evaporator by using laboratory-scale test cooling bench.

    PubMed

    Kim, Kyung Hwan; Kim, Sun Hwa; Jung, Young Rim; Kim, Man Goo

    2008-09-12

    As one of the measures to improve the environment in an automobile, malodor caused by the automobile air-conditioning system evaporator was evaluated and analyzed using laboratory-scale test cooling bench. The odor was simulated with an evaporator test cooling bench equipped with an airflow controller, air temperature and relative humidity controller. To simulate the same odor characteristics that occur from automobiles, one previously used automobile air conditioner evaporator associated with unpleasant odors was selected. The odor was evaluated by trained panels and collected with aluminum polyester bags. Collected samples were analyzed by thermal desorption into a cryotrap and subsequent gas chromatographic separation, followed by simultaneous olfactometry, flame ionization detector and identified by atomic emission detection and mass spectrometry. Compounds such as alcohols, aldehydes, and organic acids were identified as responsible odor-active compounds. Gas chromatography/flame ionization detection/olfactometry combined sensory method with instrumental analysis was very effective as an odor evaluation method in an automobile air-conditioning system evaporator.

  8. Development and operation of innovative scum to biodiesel pilot-system for the treatment of floatable wastewater scum.

    PubMed

    Anderson, Erik; Addy, Min; Chen, Paul; Ruan, Roger

    2018-02-01

    A novel process was developed for the biorefining of floatable wastewater scum and other waste oils from water treatment facilities into biodiesel and other value-added bio-products. To test the scalability and commercial potential of the technology, a 7000 l/year pilot-scale system was designed and built. Scum from a wastewater treatment facility, located in St. Paul, Mn, was collected and converted into methyl esters (biodiesel) according to the process chemistry. All of the incoming and outgoing process streams were sampled, tested, weighed and recorded to calculate both the process efficiency and product quality. Data from the pilot-scale system operation was compared to laboratory results and the theoretically expected values for each individual unit operation. The biodiesel was tested using a third party laboratory and confirmed it met all of the US EPA's test requirements for commercial-grade biodiesel. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Remarkable magnitude of the self-disproportionation of enantiomers (SDE) via achiral chromatography: application to the practical-scale enantiopurification of β-amino acid esters.

    PubMed

    Wzorek, Alicja; Sato, Azusa; Drabowicz, Józef; Soloshonok, Vadim A; Klika, Karel D

    2016-02-01

    We report the best performance yet for the self-disproportionation of enantiomers (SDE) via achiral chromatography as typically used in laboratories for the isolated yield of the excess enantiomer using N-acetyl β-amino acid ethyl esters. The results are the most convincing ever demonstration of the capability of the SDE for practical-scale enantiopurification as comparable, or even superior for some systems, to that of recrystallization. For example, from a sample of 94.4 % ee, a yield of 71 % of enantiopure material was isolated in a single chromatographic run. Moreover, the lack of an esoteric structural entity, e.g. strongly polarizing groups, such as, for instance CF3, highlights the fact that the phenomenon is not dependent on the presence of such and thus the process is relevant to any usual-type structure. In contrast to recrystallization, the procedure is predictable, general, and dependable, boding well for its widespread application in routine laboratory settings.

  10. Large-Scale Variability of Inpatient Tacrolimus Therapeutic Drug Monitoring at an Academic Transplant Center: a Retrospective Study.

    PubMed

    Strohbehn, Garth W; Pan, Warren W; Petrilli, Christopher M; Heidemann, Lauren; Larson, Sophia; Aaronson, Keith D; Johnson, Matt; Ellies, Tammy; Heung, Michael

    2018-04-30

    Inpatient tacrolimus therapeutic drug monitoring (TDM) lacks standardized guidelines. In this study, the authors analyzed variability in the pre-analytical phase of the inpatient tacrolimus TDM process at their institution. Patients receiving tacrolimus (twice-daily formulation) and tacrolimus laboratory analysis were included in the study. Times of tacrolimus administration and laboratory study collection were extracted and time distribution plots for each step in the inpatient TDM process were generated. Trough levels were drawn appropriately in 25.9% of the cases. Timing between doses was consistent, with 91.9% of the following dose administrations occurring 12 +/- 2 hours after the previous dose. Only 38.1% of the drug administrations occurred within one hour of laboratory study collection. Tacrolimus-related patient safety events were reported at a rate of 1.9 events per month while incorrect timing of TDM sample collection occurred approximately 200 times per month. Root cause analysis identified a TDM process marked by a lack of communication and coordination of drug administration and TDM sample collection. Extrapolating findings nationwide, we estimate $22 million in laboratory costs wasted annually. Based on this large single-center study, the authors concluded that the inpatient TDM process is prone to timing errors, thus is financially wasteful, and at its worst harmful to patients due to clinical decisions being made on the basis of unreliable data. Further work is needed on systems solutions to better align the laboratory study collection and drug administration processes.

  11. Preanalytical Errors in Hematology Laboratory- an Avoidable Incompetence.

    PubMed

    HarsimranKaur, Vikram Narang; Selhi, Pavneet Kaur; Sood, Neena; Singh, Aminder

    2016-01-01

    Quality assurance in the hematology laboratory is a must to ensure laboratory users of reliable test results with high degree of precision and accuracy. Even after so many advances in hematology laboratory practice, pre-analytical errors remain a challenge for practicing pathologists. This study was undertaken with an objective to evaluate the types and frequency of preanalytical errors in hematology laboratory of our center. All the samples received in the Hematology Laboratory of Dayanand Medical College and Hospital, Ludhiana, India over a period of one year (July 2013-July 2014) were included in the study and preanalytical variables like clotted samples, quantity not sufficient, wrong sample, without label, wrong label were studied. Of 471,006 samples received in the laboratory, preanalytical errors, as per the above mentioned categories was found in 1802 samples. The most common error was clotted samples (1332 samples, 0.28% of the total samples) followed by quantity not sufficient (328 sample, 0.06%), wrong sample (96 samples, 0.02%), without label (24 samples, 0.005%) and wrong label (22 samples, 0.005%). Preanalytical errors are frequent in laboratories and can be corrected by regular analysis of the variables involved. Rectification can be done by regular education of the staff.

  12. Incorporating Scale-Dependent Fracture Stiffness for Improved Reservoir Performance Prediction

    NASA Astrophysics Data System (ADS)

    Crawford, B. R.; Tsenn, M. C.; Homburg, J. M.; Stehle, R. C.; Freysteinson, J. A.; Reese, W. C.

    2017-12-01

    We present a novel technique for predicting dynamic fracture network response to production-driven changes in effective stress, with the potential for optimizing depletion planning and improving recovery prediction in stress-sensitive naturally fractured reservoirs. A key component of the method involves laboratory geomechanics testing of single fractures in order to develop a unique scaling relationship between fracture normal stiffness and initial mechanical aperture. Details of the workflow are as follows: tensile, opening mode fractures are created in a variety of low matrix permeability rocks with initial, unstressed apertures in the micrometer to millimeter range, as determined from image analyses of X-ray CT scans; subsequent hydrostatic compression of these fractured samples with synchronous radial strain and flow measurement indicates that both mechanical and hydraulic aperture reduction varies linearly with the natural logarithm of effective normal stress; these stress-sensitive single-fracture laboratory observations are then upscaled to networks with fracture populations displaying frequency-length and length-aperture scaling laws commonly exhibited by natural fracture arrays; functional relationships between reservoir pressure reduction and fracture network porosity, compressibility and directional permeabilities as generated by such discrete fracture network modeling are then exported to the reservoir simulator for improved naturally fractured reservoir performance prediction.

  13. Field evaluation of the photo-induced electron transfer fluorogenic primers (PET) real-time PCR for the detection of Plasmodium falciparum in Tanzania.

    PubMed

    Talundzic, Eldin; Maganga, Mussa; Masanja, Irene M; Peterson, David S; Udhayakumar, Venkatachalam; Lucchi, Naomi W

    2014-01-27

    Accurate diagnosis of malaria infections remains challenging, especially in the identification of submicroscopic infections. New molecular diagnostic tools that are inexpensive, sensitive enough to detect low-level infections and suitable in laboratory settings of resource-limited countries are required for malaria control and elimination programmes. Here the diagnostic potential of a recently developed photo-induced electron transfer fluorogenic primer (PET) real-time polymerase chain reaction (PCR) called PET-PCR was investigated. This study aimed to (i) evaluate the use of this assay as a method for the detection of both Plasmodium falciparum and other Plasmodium species infections in a developing country's diagnostic laboratory; and, (ii) determine the assay's sensitivity and specificity compared to a nested 18S rRNA PCR. Samples used in this study were obtained from a previous study conducted in the region of Iringa, Tanzania. A total of 303 samples from eight health facilities in Tanzania were utilized for this evaluation. All samples were screened using the multiplex PET-PCR assay designed to detect Plasmodium genus and P. falciparum initially in laboratory in Tanzania and then repeated at a reference laboratory at the CDC in the USA. Microscopy data was available for all the 303 samples. A subset of the samples were tested in a blinded fashion to find the sensitivity and specificity of the PET-PCR compared to the nested 18S rRNA PCR. Compared to microscopy, the PET-PCR assay was 59% more sensitive in detecting P. falciparum infections. The observed sensitivity and specificity were 100% (95% confidence interval (CI0.95) = 94-100%) and (CI0.95 = 96-100%), respectively, for the PET-PCR assay when compared to nested 18S rRNA PCR. When compared to 18S rRNA PCR, microscopy had a low sensitivity of 40% (CI0.95 = 23-61%) and specificity of 100% (CI0.95 = 96-100%). The PET-PCR results performed in the field laboratory in Tanzania were in 100% concordance with the results obtained at the reference laboratory in the USA. The PET-PCR is a new molecular diagnostic tool with similar performance characteristics as commonly used PCR methods that is less expensive, easy to use, and amiable to large scale-surveillance studies in developing country settings.

  14. 242-16H 2H EVAPORATOR POT SAMPLING FINAL REPORT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krementz, D; William Cheng, W

    2008-06-11

    Due to the materials that are processed through 2H Evaporator, scale is constantly being deposited on the surfaces of the evaporator pot. In order to meet the requirements of the Nuclear Criticality Safety Analysis/Evaluation (NCSA/NCSE) for 2H Evaporator, inspections of the pot are performed to determine the extent of scaling. Once the volume of scale reaches a certain threshold, the pot must be chemically cleaned to remove the scale. Prior to cleaning the pot, samples of the scale are obtained to determine the concentration of uranium and plutonium and also to provide information to assist with pot cleaning. Savannah Rivermore » National Laboratory (SRNL) was requested by Liquid Waste Organization (LWO) Engineering to obtain these samples from two locations within the evaporator. Past experience has proven the difficulty of successfully obtaining solids samples from the 2H Evaporator pot. To mitigate this risk, a total of four samplers were designed and fabricated to ensure that two samples could be obtained. Samples had previously been obtained from the cone surface directly below the vertical access riser using a custom scraping tool. This tool was fabricated and deployed successfully. A second scraper was designed to obtain sample from the nearby vertical thermowell and a third scraper was designed to obtain sample from the vertical pot wall. The newly developed scrapers both employed a pneumatically actuated elbow. The scrapers were designed to be easily attached/removed from the elbow assembly. These tools were fabricated and deployed successfully. A fourth tool was designed to obtain sample from the opposite side of the pot under the tube bundle. This tool was fabricated and tested, but the additional modifications required to make the tool field-ready could not be complete in time to meet the aggressive deployment schedule. Two samples were obtained near the pot entry location, one from the pot wall and the other from the evaporator feed pipe. Since a third sampler was available and all of the radiological controls were in place, the decision was made to obtain a third sample. The third sampler dropped directly below the riser to obtain a scrape sample from the evaporator cone. Samples were obtained from all of these locations in sufficient quantities to perform the required analysis.« less

  15. Field-scale permeability and temperature of volcanic crust from borehole data: Campi Flegrei, southern Italy

    NASA Astrophysics Data System (ADS)

    Carlino, Stefano; Piochi, Monica; Tramelli, Anna; Mormone, Angela; Montanaro, Cristian; Scheu, Bettina; Klaus, Mayer

    2018-05-01

    We report combined measurements of petrophysical and geophysical parameters for a 501-m deep borehole located on the eastern side of the active Campi Flegrei caldera (Southern Italy), namely (i) in situ permeability by pumping tests, (ii) laboratory-determined permeability of the drill core, and (iii) thermal gradients by distributed fiber optic and thermocouple sensors. The borehole was drilled during the Campi Flegrei Deep Drilling Project (in the framework of the International Continental Scientific Drilling Program) and gives information on the least explored caldera sector down to pre-caldera deposits. The results allow comparative assessment of permeability obtained from both borehole (at depth between 422 a 501 m) and laboratory tests (on a core sampled at the same depth) for permeability values of 10-13 m2 (borehole test) and 10-15 m2 (laboratory test) confirm the scale-dependency of permeability at this site. Additional geochemical and petrophysical determinations (porosity, density, chemistry, mineralogy and texture), together with gas flow measurements, corroborate the hypothesis that discrepancies in the permeability values are likely related to in-situ fracturing. The continuous distributed temperature profile points to a thermal gradient of about 200 °C km-1. Our findings (i) indicate that scale-dependency of permeability has to be carefully considered in modelling of the hydrothermal system at Campi Flegrei, and (ii) improve the understanding of caldera dynamics for monitoring and mitigation of this very high volcanic risk area.

  16. Breaking Out of the Lab: Measuring Real-Time Responses to Televised Political Content in Real-World Settings.

    PubMed

    Maier, Jürgen; Hampe, J Felix; Jahn, Nico

    2016-01-01

    Real-time response (RTR) measurement is an important technique for analyzing human processing of electronic media stimuli. Although it has been demonstrated that RTR data are reliable and internally valid, some argue that they lack external validity. The reason for this is that RTR measurement is restricted to a laboratory environment due to its technical requirements. This paper introduces a smartphone app that 1) captures real-time responses using the dial technique and 2) provides a solution for one of the most important problems in RTR measurement, the (automatic) synchronization of RTR data. In addition, it explores the reliability and validity of mobile RTR measurement by comparing the real-time reactions of two samples of young and well-educated voters to the 2013 German televised debate. Whereas the first sample participated in a classical laboratory study, the second sample was equipped with our mobile RTR system and watched the debate at home. Results indicate that the mobile RTR system yields similar results to the lab-based RTR measurement, providing evidence that laboratory studies using RTR are externally valid. In particular, the argument that the artificial reception situation creates artificial results has to be questioned. In addition, we conclude that RTR measurement outside the lab is possible. Hence, mobile RTR opens the door for large-scale studies to better understand the processing and impact of electronic media content.

  17. Breaking Out of the Lab

    PubMed Central

    Maier, Jürgen; Hampe, J. Felix; Jahn, Nico

    2016-01-01

    Real-time response (RTR) measurement is an important technique for analyzing human processing of electronic media stimuli. Although it has been demonstrated that RTR data are reliable and internally valid, some argue that they lack external validity. The reason for this is that RTR measurement is restricted to a laboratory environment due to its technical requirements. This paper introduces a smartphone app that 1) captures real-time responses using the dial technique and 2) provides a solution for one of the most important problems in RTR measurement, the (automatic) synchronization of RTR data. In addition, it explores the reliability and validity of mobile RTR measurement by comparing the real-time reactions of two samples of young and well-educated voters to the 2013 German televised debate. Whereas the first sample participated in a classical laboratory study, the second sample was equipped with our mobile RTR system and watched the debate at home. Results indicate that the mobile RTR system yields similar results to the lab-based RTR measurement, providing evidence that laboratory studies using RTR are externally valid. In particular, the argument that the artificial reception situation creates artificial results has to be questioned. In addition, we conclude that RTR measurement outside the lab is possible. Hence, mobile RTR opens the door for large-scale studies to better understand the processing and impact of electronic media content. PMID:27274577

  18. Large-scale affordable PanLeucogated CD4+ testing with proactive internal and external quality assessment: in support of the South African national comprehensive care, treatment and management programme for HIV and AIDS.

    PubMed

    Glencross, Deborah K; Janossy, George; Coetzee, Lindi M; Lawrie, Denise; Aggett, Hazel M; Scott, Lesley E; Sanne, Ian; McIntyre, James A; Stevens, Wendy

    2008-01-01

    In order to expand the treatment of human immunodeficiency virus-1 (HIV) infected patients in Africa, millions will require cost-effective CD4 counts. Supporting laboratories therefore, need to move away from crisis management and haphazard practices to organized pathology services. The authors reviewed the performance of the simplified single platform (SP) PanLeucogated (PLG) CD4 methodology, introduced into 52 laboratories across the South African National Health Laboratory Service (SA-NHLS), with a proactive approach to training, internal quality control (IQC), and external quality assessment (EQA). Two-color flow cytometry for SP PLG (CD4/CD45) was combined with the sample-by-sample bead-count-rate (BCR) IQC for bead pipetting. PLG + BCR was validated versus conventional predicate SP and dual-platform (DP) 4-color flow cytometric methods used in the first world-on 1181 samples from 250 HIV+ patients followed longitudinally on anti-retroviral therapy (ART). EQA (accuracy) was performed through the United Kingdom National External Quality Assessment Scheme (UK-NEQAS). Further EQA was performed across the 52 SA-NHLS SP-PLG laboratories participating on the CD4 African Regional External Quality Assessment Scheme (AFREQAS), to assess both accuracy and/precision between NHLS PLG laboratories. There was virtually no bias noted between SP PLG and SP predicate methods. On DP, bias and variability increased but the errors introduced were minor without affecting CD4-related clinical decisions. The simpler 2-color PLG was less expensive with additional advantages: CD4+ T-cells were discriminated from monocytes without a need for CD3-staining, and the training was faster and easier for the trainees and trainers alike. The accuracy of SP-PLG was satisfactory: all PLG results submitted to the UK NEQAS were within +/-1 Trimmed Standard Deviation (SD) of the UK NEQAS CD4 Pool Trimmed Mean. Further, on the CD4 AFREQAS, the SA-NHLS laboratories using SP-PLG + BCR showed better precision (mean %CV = 7.2%) than the CD4 methods employed in other laboratories in Africa (mean %CV = 10.7%) or on other continents (mean %CV = 12.9%). PLG + BCR accommodated high workloads, exceeding 3,000 tests/laboratory/month, with capacity for further growth around 10% per month across the SA-NHLS. The superior performance of PLG + BCR over other methods has been demonstrated. In resource-conscious countries, where large-scale ART is being introduced, flow-cytometry using PLG + BCR can make a significant impact-due to simpler operation, easier training, stricter quality assurance, and better cost-efficiency. These cost-effective flow methods can legitimately replace the more cumbersome predicate technology of the first world for ART monitoring whilst accommodating an ever-expanding national ART program and consequent extremely high workloads reached country-wide. Copyright 2008 Clinical Cytometry Society.

  19. Analysis of new measurements of Calvert Cliffs spent fuel samples using SCALE 6.2

    DOE PAGES

    Hu, Jianwei; Giaquinto, J. M.; Gauld, I. C.; ...

    2017-04-28

    High quality experimental data for isotopic compositions in irradiated fuel are important to spent fuel applications, including nuclear safeguards, spent fuel storage, transportation, and final disposal. The importance of these data has been increasingly recognized in recent years, particularly as countries like Finland and Sweden plan to open the world’s first two spent fuel geological repositories in 2020s, while other countries, including the United States, are considering extended dry fuel storage options. Destructive and nondestructive measurements of a spent fuel rod segment from a Combustion Engineering 14 × 14 fuel assembly of the Calvert Cliffs Unit 1 nuclear reactor havemore » been recently performed at Oak Ridge National Laboratory (ORNL). These ORNL measurements included two samples selected from adjacent axial locations of a fuel rod with initial enrichment of 3.038 wt% 235U, which achieved burnups close to 43.5 GWd/MTU. More than 50 different isotopes of 16 elements were measured using high precision measurement methods. Various investigations have assessed the quality of the new ORNL measurement data, including comparison to previous measurements and to calculation results. Previous measurement data for samples from the same fuel rod measured at ORNL are available from experiments performed at Pacific Northwest National Laboratory in the United States and the Khoplin Radium Institute in Russia. Detailed assembly models were developed using the newly released SCALE 6.2 code package to simulate depletion and decay of the measured fuel samples. Furthermore, results from this work show that the new ORNL measurements provide a good quality radiochemical assay data set for spent fuel with relatively high burnup and long cooling time, and they can serve as good benchmark data for nuclear burnup code validation and spent fuel studies.« less

  20. Analysis of new measurements of Calvert Cliffs spent fuel samples using SCALE 6.2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, Jianwei; Giaquinto, J. M.; Gauld, I. C.

    High quality experimental data for isotopic compositions in irradiated fuel are important to spent fuel applications, including nuclear safeguards, spent fuel storage, transportation, and final disposal. The importance of these data has been increasingly recognized in recent years, particularly as countries like Finland and Sweden plan to open the world’s first two spent fuel geological repositories in 2020s, while other countries, including the United States, are considering extended dry fuel storage options. Destructive and nondestructive measurements of a spent fuel rod segment from a Combustion Engineering 14 × 14 fuel assembly of the Calvert Cliffs Unit 1 nuclear reactor havemore » been recently performed at Oak Ridge National Laboratory (ORNL). These ORNL measurements included two samples selected from adjacent axial locations of a fuel rod with initial enrichment of 3.038 wt% 235U, which achieved burnups close to 43.5 GWd/MTU. More than 50 different isotopes of 16 elements were measured using high precision measurement methods. Various investigations have assessed the quality of the new ORNL measurement data, including comparison to previous measurements and to calculation results. Previous measurement data for samples from the same fuel rod measured at ORNL are available from experiments performed at Pacific Northwest National Laboratory in the United States and the Khoplin Radium Institute in Russia. Detailed assembly models were developed using the newly released SCALE 6.2 code package to simulate depletion and decay of the measured fuel samples. Furthermore, results from this work show that the new ORNL measurements provide a good quality radiochemical assay data set for spent fuel with relatively high burnup and long cooling time, and they can serve as good benchmark data for nuclear burnup code validation and spent fuel studies.« less

  1. How does the Textural Character of Alpine Fault Rocks Influence their Elasticity and Anisotropy

    NASA Astrophysics Data System (ADS)

    Guerin-Marthe, S.; Adam, L.; Townend, J.; Toy, V.; Doan, M. L.; Faulkner, D.

    2015-12-01

    The DFDP-1A and DFDP-1B boreholes drilled in 2011 enabled the collection of samples of unaltered Alpine Fault Zone rock. We present laboratory measurements of the elastic properties of these samples, as well as protoliths collected at outcrops. These data were collected with a unique non-contacting laser ultrasonic system, and transducers under a range of pressure conditions representative of the upper-crust. Based on the laser measurements we conclude that there is strong anisotropy in the foliated protoliths, particularly in the protomylonites. We also show that even at core scale, the anisotropy is scale dependent (there are systematic relationships between wavelength and mineral foliation). For the cataclasites, preliminary data show that elastic wave anisotropy decreases as we approach the Principal Slip Zone, in the two boreholes. The P-wave velocities exhibit a high pressure dependence for the borehole samples, meaning that most of the cracks are closed before an effective pressure of 5MPa, reducing the elastic anisotropy. However, on a cataclasite sample, the S-wave velocity measurements, polarized perpendicular and parallel to the fractures, exhibit weak anisotropy (γ=13%) at 20MPa, even when the P-wave velocity - pressure curve displays an asymptotic shape. This observation probably indicates that elastic anisotropy results from preferred mineral orientation rather than fractures. The elastic wave measurements are complemented with petrographical, XRD, XRF, SEM and CT scan analyses to understand the source of the elastic wave anisotropic behavior in the Alpine Fault damaged zone. Finally, the laboratory data are compared to the P-wave sonic log to understand the effect of elastic wave anisotropy, fluid pressures and mineralogy.

  2. The Role of Laboratory-Based Studies of the Physical and Biological Properties of Sea Ice in Supporting the Observation and Modeling of Ice Covered Seas

    NASA Astrophysics Data System (ADS)

    Light, B.; Krembs, C.

    2003-12-01

    Laboratory-based studies of the physical and biological properties of sea ice are an essential link between high latitude field observations and existing numerical models. Such studies promote improved understanding of climatic variability and its impact on sea ice and the structure of ice-dependent marine ecosystems. Controlled laboratory experiments can help identify feedback mechanisms between physical and biological processes and their response to climate fluctuations. Climatically sensitive processes occurring between sea ice and the atmosphere and sea ice and the ocean determine surface radiative energy fluxes and the transfer of nutrients and mass across these boundaries. High temporally and spatially resolved analyses of sea ice under controlled environmental conditions lend insight to the physics that drive these transfer processes. Techniques such as optical probing, thin section photography, and microscopy can be used to conduct experiments on natural sea ice core samples and laboratory-grown ice. Such experiments yield insight on small scale processes from the microscopic to the meter scale and can be powerful interdisciplinary tools for education and model parameterization development. Examples of laboratory investigations by the authors include observation of the response of sea ice microstructure to changes in temperature, assessment of the relationships between ice structure and the partitioning of solar radiation by first-year sea ice covers, observation of pore evolution and interfacial structure, and quantification of the production and impact of microbial metabolic products on the mechanical, optical, and textural characteristics of sea ice.

  3. Comparability of river suspended-sediment sampling and laboratory analysis methods

    USGS Publications Warehouse

    Groten, Joel T.; Johnson, Gregory D.

    2018-03-06

    Accurate measurements of suspended sediment, a leading water-quality impairment in many Minnesota rivers, are important for managing and protecting water resources; however, water-quality standards for suspended sediment in Minnesota are based on grab field sampling and total suspended solids (TSS) laboratory analysis methods that have underrepresented concentrations of suspended sediment in rivers compared to U.S. Geological Survey equal-width-increment or equal-discharge-increment (EWDI) field sampling and suspended sediment concentration (SSC) laboratory analysis methods. Because of this underrepresentation, the U.S. Geological Survey, in collaboration with the Minnesota Pollution Control Agency, collected concurrent grab and EWDI samples at eight sites to compare results obtained using different combinations of field sampling and laboratory analysis methods.Study results determined that grab field sampling and TSS laboratory analysis results were biased substantially low compared to EWDI sampling and SSC laboratory analysis results, respectively. Differences in both field sampling and laboratory analysis methods caused grab and TSS methods to be biased substantially low. The difference in laboratory analysis methods was slightly greater than field sampling methods.Sand-sized particles had a strong effect on the comparability of the field sampling and laboratory analysis methods. These results indicated that grab field sampling and TSS laboratory analysis methods fail to capture most of the sand being transported by the stream. The results indicate there is less of a difference among samples collected with grab field sampling and analyzed for TSS and concentration of fines in SSC. Even though differences are present, the presence of strong correlations between SSC and TSS concentrations provides the opportunity to develop site specific relations to address transport processes not captured by grab field sampling and TSS laboratory analysis methods.

  4. Comment on the International Atomic Energy Agency Report on the Advisory Group Meeting on Stable Isotope Reference Samples for Geochemical and Hydrological Investigation, Vienna, Austria, September 19-21, 1983

    USGS Publications Warehouse

    Coplen, T.B.; Friedman, Irving; O'Neil, J.R.

    1984-01-01

    According to U.S. Geological Survey records, a report prepared by R. Gonfiantini summarizing the findings and recommendations of the 1983 Advisory Group Meeting on Stable Isotope Reference Samples for Geochemical and Hydrologic Investigations held in Vienna does not accurately represent the consultants ' consensus on three important points. The consultants (1) recommended no value for the C02-H20 oxygen isotope fractionation factor, not the cited value of 1.04115, (2) adopted a value of 1.0309 rather than 1.03086 to relate the PDB and SMOW scales, and (3) adopted a firm 180 value of -2.20% for NBS-19 on the PDB scale rather than agreeing that this would be a tentative value subject to modification when more measurements in selected laboratories are available. (USGS)

  5. Simulation and flavor compound analysis of dealcoholized beer via one-step vacuum distillation.

    PubMed

    Andrés-Iglesias, Cristina; García-Serna, Juan; Montero, Olimpio; Blanco, Carlos A

    2015-10-01

    The coupled operation of vacuum distillation process to produce alcohol free beer at laboratory scale and Aspen HYSYS simulation software was studied to define the chemical changes during the dealcoholization process in the aroma profiles of 2 different lager beers. At the lab-scale process, 2 different parameters were chosen to dealcoholize beer samples, 102mbar at 50°C and 200mbar at 67°C. Samples taken at different steps of the process were analyzed by HS-SPME-GC-MS focusing on the concentration of 7 flavor compounds, 5 alcohols and 2 esters. For simulation process, the EoS parameters of the Wilson-2 property package were adjusted to the experimental data and one more pressure was tested (60mbar). Simulation methods represent a viable alternative to predict results of the volatile compound composition of a final dealcoholized beer. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Facial Width-to-Height Ratio Does Not Predict Self-Reported Behavioral Tendencies.

    PubMed

    Kosinski, Michal

    2017-11-01

    A growing number of studies have linked facial width-to-height ratio (fWHR) with various antisocial or violent behavioral tendencies. However, those studies have predominantly been laboratory based and low powered. This work reexamined the links between fWHR and behavioral tendencies in a large sample of 137,163 participants. Behavioral tendencies were measured using 55 well-established psychometric scales, including self-report scales measuring intelligence, domains and facets of the five-factor model of personality, impulsiveness, sense of fairness, sensational interests, self-monitoring, impression management, and satisfaction with life. The findings revealed that fWHR is not substantially linked with any of these self-reported measures of behavioral tendencies, calling into question whether the links between fWHR and behavior generalize beyond the small samples and specific experimental settings that have been used in past fWHR research.

  7. Web-based resources for mass-spectrometry-based metabolomics: a user's guide.

    PubMed

    Tohge, Takayuki; Fernie, Alisdair R

    2009-03-01

    In recent years, a plethora of web-based tools aimed at supporting mass-spectrometry-based metabolite profiling and metabolomics applications have appeared. Given the huge hurdles presented by the chemical diversity and dynamic range of the metabolites present in the plant kingdom, profiling the levels of a broad range of metabolites is highly challenging. Given the scale and costs involved in defining the plant metabolome, it is imperative that data are effectively shared between laboratories pursuing this goal. However, ensuring accurate comparison of samples run on the same machine within the same laboratory, let alone cross-machine and cross-laboratory comparisons, requires both careful experimentation and data interpretation. In this review, we present an overview of currently available software that aids either in peak identification or in the related field of peak alignment as well as those with utility in defining structural information of compounds and metabolic pathways.

  8. Development and Evaluation of Strong-Campbell Interest Inventory Scales to Measure Interests of Military Occupational Specialties of the Marine Corps.

    DTIC Science & Technology

    1982-08-01

    though the two groups were different in terms of SC!I scientific interests and academic orientation scores (the aviation supply sample scored higher on...51 Chemists/Physicists 50 MARINE OFFICERS- COMUNICATION 49 MARINE OFFICERS-DATA SYSTEMS 48 Engineers 47 Biologists 46 Systems Analysts/Computer...Base ( Scientific and Technical Information Office) Commander, Air Force Human Resources Laboratory, Lowry Air Force Base (Technical Training Branch

  9. Large-Scale Demonstration of Perchlorate Removal Using Weak Base Anion Resin at Well No. 3 in Rialto, California

    DTIC Science & Technology

    2012-12-01

    Nitrosodiethylamine NDMA N-Nitrosodimethylamine NDPA N-Nitrosodi-n-propylamine ng/L nanogram/liter NMEA N-Nitrosomethylethylamine NMOR N...using USEPA Method 521. N-nitrosodimethylamine ( NDMA ) was 2.6 parts per trillion (ppt) with a detection limit of 2 ppt. All other nitrosamines...was returned to service. All samples were analyzed by Weck Laboratories using USEPA Method 521. Analytes included NDEA, NDMA , NDBA, NDPA, NMEA

  10. Microwave-assisted green synthesis of silver nanostructures.

    PubMed

    Nadagouda, Mallikarjuna N; Speth, Thomas F; Varma, Rajender S

    2011-07-19

    Over the past 25 years, microwave (MW) chemistry has moved from a laboratory curiosity to a well-established synthetic technique used in many academic and industrial laboratories around the world. Although the overwhelming number of MW-assisted applications today are still performed on a laboratory (mL) scale, we expect that this enabling technology may be used on a larger, perhaps even production, scale in conjunction with radio frequency or conventional heating. Microwave chemistry is based on two main principles, the dipolar mechanism and the electrical conductor mechanism. The dipolar mechanism occurs when, under a very high frequency electric field, a polar molecule attempts to follow the field in the same alignment. When this happens, the molecules release enough heat to drive the reaction forward. In the second mechanism, the irradiated sample is an electrical conductor and the charge carriers, ions and electrons, move through the material under the influence of the electric field and lead to polarization within the sample. These induced currents and any electrical resistance will heat the sample. This Account summarizes a microwave (MW)-assisted synthetic approach for producing silver nanostructures. MW heating has received considerable attention as a promising new method for the one-pot synthesis of metallic nanostructures in solutions. Researchers have successfully demonstrated the application of this method in the preparation of silver (Ag), gold (Au), platinum (Pt), and gold-palladium (Au-Pd) nanostructures. MW heating conditions allow not only for the preparation of spherical nanoparticles within a few minutes but also for the formation of single crystalline polygonal plates, sheets, rods, wires, tubes, and dendrites. The morphologies and sizes of the nanostructures can be controlled by changing various experimental parameters, such as the concentration of metallic salt precursors, the surfactant polymers, the chain length of the surfactant polymers, the solvents, and the operation reaction temperature. In general, nanostructures with smaller sizes, narrower size distributions, and a higher degree of crystallization have been obtained more consistently via MW heating than by heating with a conventional oil-bath. The use of microwaves to heat samples is a viable avenue for the greener synthesis of nanomaterials and provides several desirable features such as shorter reaction times, reduced energy consumption, and better product yields.

  11. Atmospheric Methane Mixing Ratios--The NOAA/CMDL Global Cooperative Air Sampling Network\\, 1983-1993

    DOE Data Explorer

    Dlugokencky, E. J. [National Oceanic and Atmospheric Administration, Boulder, Colorado (USA); Lang, P. M. [National Oceanic and Atmospheric Administration, Boulder, Colorado (USA); Masarie, K. A. [National Oceanic and Atmospheric Administration, Boulder, Colorado (USA); Steele, L. P. [Commonwealth Scientific and Industrial Research Organisation, Aspendale, Victoria, Australia

    1994-01-01

    This data base presents atmospheric methane (CH4) mixing ratios from flask air samples collected over the period 1983-1993 by the National Oceanic and Atmospheric Administration, Climate Monitoring and Diagnostics Laboratory's (NOAA/CMDL's) global cooperative air sampling network. Air samples were collected approximately once per week at 44 fixed sites (37 of which were still active at the end of 1993). Samples were also collected at 5 degree latitude intervals along shipboard cruise tracks in the Pacific Ocean between North America and New Zealand (or Australia) and at 3 degree latitude intervals along cruise tracks in the South China Sea between Singapore and Hong Kong. The shipboard measurements were made approximately every 3 weeks per latitude zone by each of two ships in the Pacific Ocean and approximately once every week per latitude zone in the South China Sea. All samples were analyzed for CH4 at the NOAA/CMDL laboratory in Boulder, Colorado, by gas chromatography with flame ionization detection, and each aliquot was referenced to the NOAA/CMDL methane standard scale. In addition to providing the complete set of atmospheric CH4 measurements from flask air samples collected at the NOAA/CMDL network sites, this data base also includes files which list monthly mean mixing ratios derived from the individual flask air measurements. These monthly summary data are available for 35 of the fixed sites and 21 of the shipboard sampling sites.

  12. Estimating porosity and solid dielectric permittivity in the Miami Limestone using high-frequency ground penetrating radar (GPR) measurements at the laboratory scale

    NASA Astrophysics Data System (ADS)

    Mount, Gregory J.; Comas, Xavier

    2014-10-01

    Subsurface water flow in South Florida is largely controlled by the heterogeneous nature of the karst limestone in the Biscayne aquifer and its upper formation, the Miami Limestone. These heterogeneities are amplified by dissolution structures that induce changes in the aquifer's material and physical properties (i.e., porosity and dielectric permittivity) and create preferential flow paths. Understanding such patterns are critical for the development of realistic groundwater flow models, particularly in the Everglades, where restoration of hydrological conditions is intended. In this work, we used noninvasive ground penetrating radar (GPR) to estimate the spatial variability in porosity and the dielectric permittivity of the solid phase of the limestone at centimeter-scale resolution to evaluate the potential for field-based GPR studies. A laboratory setup that included high-frequency GPR measurements under completely unsaturated and saturated conditions was used to estimate changes in electromagnetic wave velocity through Miami Limestone samples. The Complex Refractive Index Model was used to derive estimates of porosity and dielectric permittivity of the solid phase of the limestone. Porosity estimates of the samples ranged between 45.2 and 66.0% and showed good correspondence with estimates of porosity using analytical and digital image techniques. Solid dielectric permittivity values ranged between 7.0 and 13.0. This study shows the ability of GPR to image the spatial variability of porosity and dielectric permittivity in the Miami Limestone and shows potential for expanding these results to larger scales and other karst aquifers.

  13. Role of Skill Laboratory Training in Medical Education - Students’ Perspective.

    PubMed

    Hashim, Rizwan; Qamar, Khadija; Khan, Muhammad Alamgir; Rehman, Sabah

    2016-03-01

    To evaluate the perceptions of medical students regarding their training utilizing facilities provided in the skill laboratory of a public sector medical college. Cross-sectional study. Army Medical College, Rawalpindi, from October to December 2014. Students of final year MBBS who had underwent skill laboratory training were recruited through convenience purposive sampling. Students not exposed to skill laboratory training were excluded. Data collection tool was a questionnaire having 23 questions with responses on Likert Scale as strongly disagree, disagree, agree and strongly agree coded as 1, 2, 3 and 4, respectively. Data was analysed on SPSS version 22. There were 78 (57%) male and 59 (43%) female students out of 137, with mean age of 22.59 ±0.74 years. The response rate was 68.5%. Cronbach's Alpha test was 0.84 showing high reliability. The mean of sum of all the 23 items was 63.85 ±8.71, whereas item means was 2.78 ±0.38, reflecting a high inclination of students towards skill laboratory training. Frequency of students responding in favour of skill laboratory training was significantly high (p < 0.05). Medical students perceived skill laboratory training as a favoured learning strategy as compared to practising on real patients for acquisition of various aspects of clinical skills, knowledge and attitude.

  14. Interlaboratory comparability, bias, and precision for four laboratories measuring analytes in wet deposition, October 1983-December 1984

    USGS Publications Warehouse

    Brooks, Myron H.; Schroder, LeRoy J.; Willoughby, Timothy C.

    1987-01-01

    Four laboratories involved in the routine analysis of wet-deposition samples participated in an interlaboratory comparison program managed by the U.S. Geological Survey. The four participants were: Illinois State Water Survey central analytical laboratory in Champaign, Illinois; U.S. Geological Survey national water-quality laboratories in Atlanta, Georgia, and Denver, Colorado; and Inland Waters Directorate national water-quality laboratory in Burlington, Ontario, Canada. Analyses of interlaboratory samples performed by the four laboratories from October 1983 through December 1984 were compared.Participating laboratories analyzed three types of interlaboratory samples--natural wet deposition, simulated wet deposition, and deionized water--for pH and specific conductance, and for dissolved calcium, magnesium, sodium, sodium, potassium, chloride, sulfate, nitrate, ammonium, and orthophosphate. Natural wet-deposition samples were aliquots of actual wet-deposition samples. Analyses of these samples by the four laboratories were compared using analysis of variance. Test results indicated that pH, calcium, nitrate, and ammonium results were not directly comparable among the four laboratories. Statistically significant differences between laboratory results probably only were meaningful for analyses of dissolved calcium. Simulated wet-deposition samples with known analyte concentrations were used to test each laboratory for analyte bias. Laboratory analyses of calcium, magnesium, sodium, potassium, chloride, sulfate, and nitrate were not significantly different from the known concentrations of these analytes when tested using analysis of variance. Deionized-water samples were used to test each laboratory for reporting of false positive values. The Illinois State Water Survey Laboratory reported the smallest percentage of false positive values for most analytes. Analyte precision was estimated for each laboratory from results of replicate measurements. In general, the Illinois State Water Survey laboratory achieved the greatest precision, whereas the U.S. Geological Survey laboratories achieved the least precision.

  15. Comparison of microbiological diagnosis of urinary tract infection in young children by routine health service laboratories and a research laboratory: Diagnostic cohort study

    PubMed Central

    Birnie, Kate; Hay, Alastair D.; Wootton, Mandy; Howe, Robin; MacGowan, Alasdair; Whiting, Penny; Lawton, Michael; Delaney, Brendan; Downing, Harriet; Dudley, Jan; Hollingworth, William; Lisles, Catherine; Little, Paul; O’Brien, Kathryn; Pickles, Timothy; Rumsby, Kate; Thomas-Jones, Emma; Van der Voort, Judith; Waldron, Cherry-Ann; Harman, Kim; Hood, Kerenza; Butler, Christopher C.; Sterne, Jonathan A. C.

    2017-01-01

    Objectives To compare the validity of diagnosis of urinary tract infection (UTI) through urine culture between samples processed in routine health service laboratories and those processed in a research laboratory. Population and methods We conducted a prospective diagnostic cohort study in 4808 acutely ill children aged <5 years attending UK primary health care. UTI, defined as pure/predominant growth ≥105 CFU/mL of a uropathogen (the reference standard), was diagnosed at routine health service laboratories and a central research laboratory by culture of urine samples. We calculated areas under the receiver-operator curve (AUC) for UTI predicted by pre-specified symptoms, signs and dipstick test results (the “index test”), separately according to whether samples were obtained by clean catch or nappy (diaper) pads. Results 251 (5.2%) and 88 (1.8%) children were classified as UTI positive by health service and research laboratories respectively. Agreement between laboratories was moderate (kappa = 0.36; 95% confidence interval [CI] 0.29, 0.43), and better for clean catch (0.54; 0.45, 0.63) than nappy pad samples (0.20; 0.12, 0.28). In clean catch samples, the AUC was lower for health service laboratories (AUC = 0.75; 95% CI 0.69, 0.80) than the research laboratory (0.86; 0.79, 0.92). Values of AUC were lower in nappy pad samples (0.65 [0.61, 0.70] and 0.79 [0.70, 0.88] for health service and research laboratory positivity, respectively) than clean catch samples. Conclusions The agreement of microbiological diagnosis of UTI comparing routine health service laboratories with a research laboratory was moderate for clean catch samples and poor for nappy pad samples and reliability is lower for nappy pad than for clean catch samples. Positive results from the research laboratory appear more likely to reflect real UTIs than those from routine health service laboratories, many of which (particularly from nappy pad samples) could be due to contamination. Health service laboratories should consider adopting procedures used in the research laboratory for paediatric urine samples. Primary care clinicians should try to obtain clean catch samples, even in very young children. PMID:28199403

  16. Patient satisfaction with clinical laboratory services at Tikur Anbessa Specialized Hospital, Addis Ababa, Ethiopia

    PubMed Central

    Abera, Rodas Getachew; Abota, Boaz Arka; Legese, Melese Hailu; Negesso, Abebe Edao

    2017-01-01

    Background Monitoring patient satisfaction is an important and useful quality improvement tool for clinical laboratories in particular and health care organizations in general. Thus, this study aimed to assess patient satisfaction toward clinical laboratory services at Tikur Anbessa Specialized Hospital (TASH), Addis Ababa, Ethiopia. Methods A hospital-based cross-sectional study was conducted and a convenient sampling technique was applied to recruit study participants. A total of 210 patients who had received laboratory services were included. A self-administered predesigned, pretested, structured questionnaire was used, and data were collected through face-to-face interviews. A 5-point Likert scale with 1 and 5 indicating the lowest and highest levels of satisfaction, respectively, was used and their weighted average was used to categorize the satisfaction level of the patients. Chi square test was used (taking P≤0.05 as the statistically significant level) to find out if any association existed between the level of satisfaction and different attributes. Data were analyzed using SPSS version 20. Results The overall level of patient satisfaction toward clinical laboratory services in this study was 59.7% with a response rate of 210 (100%). The Likert scale results of patient satisfaction of the laboratory services revealed that the mean rating values ranged from 3.05 (±1.12) to 4.12 (±1.08) out of a possible 5. Among the different indicators, patients were highly satisfied with the cleanliness of facility (82%), maintenance of privacy and confidentiality (83.2%), and the cost of the laboratory service (86.5%), while they were dissatisfied with the location of the laboratory (56%), latrine accessibility and availability (58.4%), and latrine cleanness and comfort (63.8%). Conclusion The whole availability of requested tests, availability of place in blood drawing room to put personal things, and waiting time for specimen collection were found to have a statistically significant association with the overall satisfaction of patients toward clinical laboratory services. Therefore, these could be the possible determinants among others that account for the dissatisfaction of patients with clinical laboratory services. PMID:28761333

  17. Occurrence, leaching, and degradation of Cry1Ab protein from transgenic maize detritus in agricultural streams

    DOE PAGES

    Griffiths, Natalie A.; Tank, Jennifer L.; Royer, Todd V.; ...

    2017-03-15

    The insecticidal Cry1Ab protein expressed by transgenic (Bt) maize can enter adjacent water bodies via multiple pathways, but its fate in stream ecosystems is not as well studied as in terrestrial systems. In this study, we used a combination of field sampling and laboratory experiments to examine the occurrence, leaching, and degradation of soluble Cry1Ab protein derived from Bt maize in agricultural streams. We surveyed 11 agricultural streams in northwestern Indiana, USA, on 6 dates that encompassed the growing season, crop harvest, and snowmelt/spring flooding, and detected Cry1Ab protein in the water column and in flowing subsurface tile drains atmore » concentrations of 3–60 ng/L. In a series of laboratory experiments, submerged Bt maize leaves leached Cry1Ab into stream water with 1% of the protein remaining in leaves after 70 d. Laboratory experiments suggested that dissolved Cry1Ab protein degraded rapidly in microcosms containing water-column microorganisms, and light did not enhance breakdown by stimulating assimilatory uptake of the protein by autotrophs. Here, the common detection of Cry1Ab protein in streams sampled across an agricultural landscape, combined with laboratory studies showing rapid leaching and degradation, suggests that Cry1Ab may be pseudo-persistent at the watershed scale due to the multiple input pathways from the surrounding terrestrial environment.« less

  18. Occurrence, leaching, and degradation of Cry1Ab protein from transgenic maize detritus in agricultural streams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Griffiths, Natalie A.; Tank, Jennifer L.; Royer, Todd V.

    The insecticidal Cry1Ab protein expressed by transgenic (Bt) maize can enter adjacent water bodies via multiple pathways, but its fate in stream ecosystems is not as well studied as in terrestrial systems. In this study, we used a combination of field sampling and laboratory experiments to examine the occurrence, leaching, and degradation of soluble Cry1Ab protein derived from Bt maize in agricultural streams. We surveyed 11 agricultural streams in northwestern Indiana, USA, on 6 dates that encompassed the growing season, crop harvest, and snowmelt/spring flooding, and detected Cry1Ab protein in the water column and in flowing subsurface tile drains atmore » concentrations of 3–60 ng/L. In a series of laboratory experiments, submerged Bt maize leaves leached Cry1Ab into stream water with 1% of the protein remaining in leaves after 70 d. Laboratory experiments suggested that dissolved Cry1Ab protein degraded rapidly in microcosms containing water-column microorganisms, and light did not enhance breakdown by stimulating assimilatory uptake of the protein by autotrophs. Here, the common detection of Cry1Ab protein in streams sampled across an agricultural landscape, combined with laboratory studies showing rapid leaching and degradation, suggests that Cry1Ab may be pseudo-persistent at the watershed scale due to the multiple input pathways from the surrounding terrestrial environment.« less

  19. A guide for the laboratory information management system (LIMS) for light stable isotopes--Versions 7 and 8

    USGS Publications Warehouse

    Coplen, Tyler B.

    2000-01-01

    The reliability and accuracy of isotopic data can be improved by utilizing database software to (i) store information about samples, (ii) store the results of mass spectrometric isotope-ratio analyses of samples, (iii) calculate analytical results using standardized algorithms stored in a database, (iv) normalize stable isotopic data to international scales using isotopic reference materials, and (v) generate multi-sheet paper templates for convenient sample loading of automated mass-spectrometer sample preparation manifolds. Such a database program, the Laboratory Information Management System (LIMS) for Light Stable Isotopes, is presented herein. Major benefits of this system include (i) a dramatic improvement in quality assurance, (ii) an increase in laboratory efficiency, (iii) a reduction in workload due to the elimination or reduction of retyping of data by laboratory personnel, and (iv) a decrease in errors in data reported to sample submitters. Such a database provides a complete record of when and how often laboratory reference materials have been analyzed and provides a record of what correction factors have been used through time. It provides an audit trail for laboratories. LIMS for Light Stable Isotopes is available for both Microsoft Office 97 Professional and Microsoft Office 2000 Professional as versions 7 and 8, respectively. Both source code (mdb file) and precompiled executable files (mde) are available. Numerous improvements have been made for continuous flow isotopic analysis in this version (specifically 7.13 for Microsoft Access 97 and 8.13 for Microsoft Access 2000). It is much easier to import isotopic results from Finnigan ISODAT worksheets, even worksheets on which corrections for amount of sample (linearity corrections) have been added. The capability to determine blank corrections using isotope mass balance from analyses of elemental analyzer samples has been added. It is now possible to calculate and apply drift corrections to isotopic data based on the time of day of analysis. Whereas Finnigan ISODAT software is confined to using only a single peak for calculating delta values, LIMS now enables one to use the mean of two or more reference injections during a continuous flow analysis to calculate delta values. This is useful with Finnigan?s GasBench II online sample preparation system. Concentrations of carbon, nitrogen, and sulfur can be calculated based one or more isotopic reference materials analyzed with a group of samples. Both sample data and isotopic analysis data can now be exported to Excel files. A calculator for determining the amount of sample needed for isotopic analysis based on a previous amount of sample and continuous flow area is now an integral part of LIMS for Light Stable Isotopes. LIMS for Light Stable Isotopes can now assign an error code to Finnigan elemental analyzer analyses in which one of the electrometers has saturated due to analysis of too much sample material, giving rise to incorrect isotopic abundances. Information on downloading this report and downloading code and databases is provided at the Internet addresses: http://water.usgs.gov/software/geochemical.html or http://www.geogr.uni-jena.de/software/geochemical.html in the Eastern Hemisphere.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Plemons, R.E.; Hopwood, W.H. Jr.; Hamilton, J.H.

    For a number of years the Oak Ridge Y-12 Plant Laboratory has been analyzing coal predominately for the utilities department of the Y-12 Plant. All laboratory procedures, except a Leco sulfur method which used the Leco Instruction Manual as a reference, were written based on the ASTM coal analyses. Sulfur is analyzed at the present time by two methods, gravimetric and Leco. The laboratory has two major endeavors for monitoring the quality of its coal analyses. (1) A control program by the Plant Statistical Quality Control Department. Quality Control submits one sample for every nine samples submitted by the utilitiesmore » departments and the laboratory analyzes a control sample along with the utilities samples. (2) An exchange program with the DOE Coal Analysis Laboratory in Bruceton, Pennsylvania. The Y-12 Laboratory submits to the DOE Coal Laboratory, on even numbered months, a sample that Y-12 has analyzed. The DOE Coal Laboratory submits, on odd numbered months, one of their analyzed samples to the Y-12 Plant Laboratory to be analyzed. The results of these control and exchange programs are monitored not only by laboratory personnel, but also by Statistical Quality Control personnel who provide statistical evaluations. After analysis and reporting of results, all utilities samples are retained by the laboratory until the coal contracts have been settled. The utilities departments have responsibility for the initiation and preparation of the coal samples. The samples normally received by the laboratory have been ground to 4-mesh, reduced to 0.5-gallon quantities, and sealed in air-tight containers. Sample identification numbers and a Request for Analysis are generated by the utilities departments.« less

  1. Progress of organic matter degradation and maturity of compost produced in a large-scale composting facility.

    PubMed

    Nakasaki, Kiyohiko; Marui, Taketoshi

    2011-06-01

    To monitor the progress of organic matter degradation in a large-scale composting facility, the percentage of organic matter degradation was determined by measuring CO(2) evolution during recomposting of compost samples withdrawn from the facility. The percentage of organic matter degradation was calculated as the ratio of the amount of CO(2) evolved from compost raw material to that evolved from each sample during recomposting in the laboratory composting apparatus. It was assumed that the difference in the cumulative emission of CO(2) between the compost raw material and a sample corresponds to the amount of CO( 2) evolved from the sample in the composting facility. Using this method, the changes in organic matter degradation during composting in practical large-scale composting facilities were estimated and it was found that the percentage of organic matter degradation increased more vigorously in the earlier stages than in the later stages of composting. The percentage of organic matter degradation finally reached 78 and 55% for the compost produced from garbage-animal manure mixture and distillery waste (shochu residue), respectively. It was thus ascertained that organic matter degradation progressed well in both composting facilities. Furthermore, by performing a plant growth assay, it was observed that the compost products of both the facilities did not inhibit seed germination and thus were useful in promoting plant growth.

  2. A comparison of refuse attenuation in laboratory and field scale lysimeters.

    PubMed

    Youcai, Zhao; Luochun, Wang; Renhua, Hua; Dimin, Xu; Guowei, Gu

    2002-01-01

    For this study, small and middle scale laboratory lysimeters, and a large scale field lysimeter in situ in Shanghai Refuse Landfill, with refuse weights of 187,600 and 10,800,000 kg, respectively, were created. These lysimeters are compared in terms of leachate quality (pH, concentrations of COD, BOD and NH3-N), refuse composition (biodegradable matter and volatile solid) and surface settlement for a monitoring period of 0-300 days. The objectives of this study were to explore both the similarities and disparities between laboratory and field scale lysimeters, and to compare degradation behaviors of refuse at the intensive reaction phase in the different scale lysimeters. Quantitative relationships of leachate quality and refuse composition with placement time show that degradation behaviors of refuse seem to depend heavily on the scales of the lysimeters and the parameters of concern, especially in the starting period of 0-6 months. However, some similarities exist between laboratory and field lysimeters after 4-6 months of placement because COD and BOD concentrations in leachate in the field lysimeter decrease regularly in a parallel pattern with those in the laboratory lysimeters. NH3-N, volatile solid (VS) and biodegradable matter (BDM) also gradually decrease in parallel in this intensive reaction phase for all scale lysimeters as refuse ages. Though the concrete data are different among the different scale lysimeters, it may be considered that laboratory lysimeters with sufficient scale are basically applicable for a rough simulation of a real landfill, especially for illustrating the degradation pattern and mechanism. Settlement of refuse surface is roughly proportional to the initial refuse height.

  3. Dehydration-driven stress transfer triggers intermediate-depth earthquakes

    PubMed Central

    Ferrand, Thomas P.; Hilairet, Nadège; Incel, Sarah; Deldicque, Damien; Labrousse, Loïc; Gasc, Julien; Renner, Joerg; Wang, Yanbin; Green II, Harry W.; Schubnel, Alexandre

    2017-01-01

    Intermediate-depth earthquakes (30–300 km) have been extensively documented within subducting oceanic slabs, but their mechanics remains enigmatic. Here we decipher the mechanism of these earthquakes by performing deformation experiments on dehydrating serpentinized peridotites (synthetic antigorite-olivine aggregates, minerals representative of subduction zones lithologies) at upper mantle conditions. At a pressure of 1.1 gigapascals, dehydration of deforming samples containing only 5 vol% of antigorite suffices to trigger acoustic emissions, a laboratory-scale analogue of earthquakes. At 3.5 gigapascals, acoustic emissions are recorded from samples with up to 50 vol% of antigorite. Experimentally produced faults, observed post-mortem, are sealed by fluid-bearing micro-pseudotachylytes. Microstructural observations demonstrate that antigorite dehydration triggered dynamic shear failure of the olivine load-bearing network. These laboratory analogues of intermediate-depth earthquakes demonstrate that little dehydration is required to trigger embrittlement. We propose an alternative model to dehydration-embrittlement in which dehydration-driven stress transfer, rather than fluid overpressure, causes embrittlement. PMID:28504263

  4. Dehydration-driven stress transfer triggers intermediate-depth earthquakes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferrand, Thomas P.; Hilairet, Nadège; Incel, Sarah

    Intermediate-depth earthquakes (30–300 km) have been extensively documented within subducting oceanic slabs, but their mechanics remains enigmatic. Here in this paper we decipher the mechanism of these earthquakes by performing deformation experiments on dehydrating serpentinized peridotites (synthetic antigorite-olivine aggregates, minerals representative of subduction zones lithologies) at upper mantle conditions. At a pressure of 1.1 gigapascals, dehydration of deforming samples containing only 5 vol% of antigorite suffices to trigger acoustic emissions, a laboratory-scale analogue of earthquakes. At 3.5 gigapascals, acoustic emissions are recorded from samples with up to 50 vol% of antigorite. Experimentally produced faults, observed post-mortem, are sealed by fluid-bearingmore » micro-pseudotachylytes. Microstructural observations demonstrate that antigorite dehydration triggered dynamic shear failure of the olivine load-bearing network. These laboratory analogues of intermediatedepth earthquakes demonstrate that little dehydration is required to trigger embrittlement. We propose an alternative model to dehydration-embrittlement in which dehydration-driven stress transfer, rather than fluid overpressure, causes embrittlement.« less

  5. Dehydration-driven stress transfer triggers intermediate-depth earthquakes

    DOE PAGES

    Ferrand, Thomas P.; Hilairet, Nadège; Incel, Sarah; ...

    2017-05-15

    Intermediate-depth earthquakes (30–300 km) have been extensively documented within subducting oceanic slabs, but their mechanics remains enigmatic. Here in this paper we decipher the mechanism of these earthquakes by performing deformation experiments on dehydrating serpentinized peridotites (synthetic antigorite-olivine aggregates, minerals representative of subduction zones lithologies) at upper mantle conditions. At a pressure of 1.1 gigapascals, dehydration of deforming samples containing only 5 vol% of antigorite suffices to trigger acoustic emissions, a laboratory-scale analogue of earthquakes. At 3.5 gigapascals, acoustic emissions are recorded from samples with up to 50 vol% of antigorite. Experimentally produced faults, observed post-mortem, are sealed by fluid-bearingmore » micro-pseudotachylytes. Microstructural observations demonstrate that antigorite dehydration triggered dynamic shear failure of the olivine load-bearing network. These laboratory analogues of intermediatedepth earthquakes demonstrate that little dehydration is required to trigger embrittlement. We propose an alternative model to dehydration-embrittlement in which dehydration-driven stress transfer, rather than fluid overpressure, causes embrittlement.« less

  6. Beyond-laboratory-scale prediction for channeling flows through subsurface rock fractures with heterogeneous aperture distributions revealed by laboratory evaluation

    NASA Astrophysics Data System (ADS)

    Ishibashi, Takuya; Watanabe, Noriaki; Hirano, Nobuo; Okamoto, Atsushi; Tsuchiya, Noriyoshi

    2015-01-01

    The present study evaluates aperture distributions and fluid flow characteristics for variously sized laboratory-scale granite fractures under confining stress. As a significant result of the laboratory investigation, the contact area in fracture plane was found to be virtually independent of scale. By combining this characteristic with the self-affine fractal nature of fracture surfaces, a novel method for predicting fracture aperture distributions beyond laboratory scale is developed. Validity of this method is revealed through reproduction of the results of laboratory investigation and the maximum aperture-fracture length relations, which are reported in the literature, for natural fractures. The present study finally predicts conceivable scale dependencies of fluid flows through joints (fractures without shear displacement) and faults (fractures with shear displacement). Both joint and fault aperture distributions are characterized by a scale-independent contact area, a scale-dependent geometric mean, and a scale-independent geometric standard deviation of aperture. The contact areas for joints and faults are approximately 60% and 40%. Changes in the geometric means of joint and fault apertures (µm), em, joint and em, fault, with fracture length (m), l, are approximated by em, joint = 1 × 102 l0.1 and em, fault = 1 × 103 l0.7, whereas the geometric standard deviations of both joint and fault apertures are approximately 3. Fluid flows through both joints and faults are characterized by formations of preferential flow paths (i.e., channeling flows) with scale-independent flow areas of approximately 10%, whereas the joint and fault permeabilities (m2), kjoint and kfault, are scale dependent and are approximated as kjoint = 1 × 10-12 l0.2 and kfault = 1 × 10-8 l1.1.

  7. Prevalence and types of preanalytical error in hematology laboratory of a tertiary care hospital in South India.

    PubMed

    Arul, Pitchaikaran; Pushparaj, Magesh; Pandian, Kanmani; Chennimalai, Lingasamy; Rajendran, Karthika; Selvaraj, Eniya; Masilamani, Suresh

    2018-01-01

    An important component of laboratory medicine is preanalytical phase. Since laboratory report plays a major role in patient management, more importance should be given to the quality of laboratory tests. The present study was undertaken to find the prevalence and types of preanalytical errors at a tertiary care hospital in South India. In this cross-sectional study, a total of 118,732 samples ([62,474 outpatient department [OPD] and 56,258 inpatient department [IPD]) were received in hematology laboratory. These samples were analyzed for preanalytical errors such as misidentification, incorrect vials, inadequate samples, clotted samples, diluted samples, and hemolyzed samples. The overall prevalence of preanalytical errors found was 513 samples, which is 0.43% of the total number of samples received. The most common preanalytical error observed was inadequate samples followed by clotted samples. Overall frequencies (both OPD and IPD) of preanalytical errors such as misidentification, incorrect vials, inadequate samples, clotted samples, diluted samples, and hemolyzed samples were 0.02%, 0.05%, 0.2%, 0.12%, 0.02%, and 0.03%, respectively. The present study concluded that incorrect phlebotomy techniques due to lack of awareness is the main reason for preanalytical errors. This can be avoided by proper communication and coordination between laboratory and wards, proper training and continuing medical education programs for laboratory and paramedical staffs, and knowledge of the intervening factors that can influence laboratory results.

  8. Perceptual and Affective Responses to Sampled Capsaicin Differ by Reported Intake

    PubMed Central

    Nolden, Alissa A.; Hayes, John E.

    2016-01-01

    The present study was conducted to a) generate suprathresold dose-response functions for multiple qualities evoked by capsaicin across a wide range of concentrations, and b) revisit how intensity ratings and liking may differ as a function of self reported intake. Individuals rated eight samples of capsaicin for perceived burn and bitterness, as well as disliking/liking. Measures of reported preference for chili peppers, chili intake frequency, prior experience and personality measures were also assessed. Here, we confirm prior findings showing that burn in the laboratory differs with reported chili intake, with infrequent consumers reporting more burn. We extend these findings by exploring how capsaicin perception varies by reported liking, and measures of variety seeking. We also address the question of whether differences in burn ratings may potentially be an artifact of differential scale usage across groups due to prior experience, and not chronic desensitization, as is typically assumed. By using generalized scaling methods and recalled sensations, we conclude the differences observed here and elsewhere are not likely due to differences in how participants use rating scales. PMID:28392628

  9. An efficient and scalable analysis framework for variant extraction and refinement from population-scale DNA sequence data.

    PubMed

    Jun, Goo; Wing, Mary Kate; Abecasis, Gonçalo R; Kang, Hyun Min

    2015-06-01

    The analysis of next-generation sequencing data is computationally and statistically challenging because of the massive volume of data and imperfect data quality. We present GotCloud, a pipeline for efficiently detecting and genotyping high-quality variants from large-scale sequencing data. GotCloud automates sequence alignment, sample-level quality control, variant calling, filtering of likely artifacts using machine-learning techniques, and genotype refinement using haplotype information. The pipeline can process thousands of samples in parallel and requires less computational resources than current alternatives. Experiments with whole-genome and exome-targeted sequence data generated by the 1000 Genomes Project show that the pipeline provides effective filtering against false positive variants and high power to detect true variants. Our pipeline has already contributed to variant detection and genotyping in several large-scale sequencing projects, including the 1000 Genomes Project and the NHLBI Exome Sequencing Project. We hope it will now prove useful to many medical sequencing studies. © 2015 Jun et al.; Published by Cold Spring Harbor Laboratory Press.

  10. Direct magnetocaloric characterization and simulation of thermomagnetic cycles

    NASA Astrophysics Data System (ADS)

    Porcari, G.; Buzzi, M.; Cugini, F.; Pellicelli, R.; Pernechele, C.; Caron, L.; Brück, E.; Solzi, M.

    2013-07-01

    An experimental setup for the direct measurement of the magnetocaloric effect capable of simulating high frequency magnetothermal cycles on laboratory-scale samples is described. The study of the magnetocaloric properties of working materials under operative conditions is fundamental for the development of innovative devices. Frequency and time dependent characterization can provide essential information on intrinsic features such as magnetic field induced fatigue in materials undergoing first order magnetic phase transitions. A full characterization of the adiabatic temperature change performed for a sample of Gadolinium across its Curie transition shows the good agreement between our results and literature data and in-field differential scanning calorimetry.

  11. Fault Damage Zone Permeability in Crystalline Rocks from Combined Field and Laboratory Measurements

    NASA Astrophysics Data System (ADS)

    Mitchell, T.; Faulkner, D.

    2008-12-01

    In nature, permeability is enhanced in the damage zone of faults, where fracturing occurs on a wide range of scales. Here we analyze the contribution of microfracture damage on the permeability of faults that cut through low porosity, crystalline rocks by combining field and laboratory measurements. Microfracture densities surrounding strike-slip faults with well-constrained displacements ranging over 3 orders of magnitude (~0.12 m - 5000 m) have been analyzed. The faults studied are excellently exposed within the Atacama Fault Zone, where exhumation from 6-10 km has occurred. Microfractures in the form of fluid inclusion planes (FIPs) show a log-linear decrease in fracture density with perpendicular distance from the fault core. Damage zone widths defined by the density of FIPs scale with fault displacement, and an empirical relationship for microfracture density distribution throughout the damage zone with displacement is derived. Damage zone rocks will have experienced differential stresses that were less than, but some proportion of, the failure stress. As such, permeability data from progressively loaded, initially intact laboratory samples, in the pre-failure region provide useful insights into fluid flow properties of various parts of the damage zone. The permeability evolution of initially intact crystalline rocks under increasing differential load leading to macroscopic failure was determined at water pore pressures of 50 MPa and effective pressure of 10 MPa. Permeability is seen to increase by up to, and over, two orders of magnitude prior to macroscopic failure. Further experiments were stopped at various points in the loading history in order to correlate microfracture density within the samples with permeability. By combining empirical relationships determined from both quantitative fieldwork and experiments we present a model that allows microfracture permeability distribution throughout the damage zone to be determined as function of increasing fault displacement.

  12. Novel laboratory methods for determining the fine scale electrical resistivity structure of core

    NASA Astrophysics Data System (ADS)

    Haslam, E. P.; Gunn, D. A.; Jackson, P. D.; Lovell, M. A.; Aydin, A.; Prance, R. J.; Watson, P.

    2014-12-01

    High-resolution electrical resistivity measurements are made on saturated rocks using novel laboratory instrumentation and multiple electrical voltage measurements involving in principle a four-point electrode measurement but with a single, moving electrode. Flat, rectangular core samples are scanned by varying the electrode position over a range of hundreds of millimetres with an accuracy of a tenth of a millimetre. Two approaches are tested involving a contact electrode and a non-contact electrode arrangement. The first galvanic method uses balanced cycle switching of a floating direct current (DC) source to minimise charge polarisation effects masking the resistivity distribution related to fine scale structure. These contacting electrode measurements are made with high common mode noise rejection via differential amplification with respect to a reference point within the current flow path. A computer based multifunction data acquisition system logs the current through the sample and voltages along equipotentials from which the resistivity measurements are derived. Multiple measurements are combined to create images of the surface resistivity structure, with variable spatial resolution controlled by the electrode spacing. Fine scale sedimentary features and open fractures in saturated rocks are interpreted from the measurements with reference to established relationships between electrical resistivity and porosity. Our results successfully characterise grainfall lamination and sandflow cross-stratification in a brine saturated, dune bedded core sample representative of a southern North Sea reservoir sandstone, studied using the system in constant current, variable voltage mode. In contrast, in a low porosity marble, identification of open fracture porosity against a background very low matrix porosity is achieved using the constant voltage, variable current mode. This new system is limited by the diameter of the electrode that for practical reasons can only be reduced to between 0.5 and 0.75 mm. Improvements to this resolution may be achieved by further reducing the electrode footprint to 0.1 mm × 0.1 mm using a novel high-impedance, non-contact potential probe. Initial results with this non-contact electric potential sensor indicate the possibility for generating images with grain-scale resolution.

  13. Inter-laboratory comparison study on measuring semi-volatile organic chemicals in standards and air samples.

    PubMed

    Su, Yushan; Hung, Hayley

    2010-11-01

    Measurements of semi-volatile organic chemicals (SVOCs) were compared among 21 laboratories from 7 countries through the analysis of standards, a blind sample, an air extract, and an atmospheric dust sample. Measurement accuracy strongly depended on analytes, laboratories, and types of standards and samples. Intra-laboratory precision was generally good with relative standard deviations (RSDs) of triplicate injections <10% and with median differences of duplicate samples between 2.1 and 22%. Inter-laboratory variability, measured by RSDs of all measurements, was in the range of 2.8-58% in analyzing standards, and 6.9-190% in analyzing blind sample and air extract. Inter-laboratory precision was poorer when samples were subject to cleanup processes, or when SVOCs were quantified at low concentrations. In general, inter-laboratory differences up to a factor of 2 can be expected to analyze atmospheric SVOCs. When comparing air measurements from different laboratories, caution should be exercised if the data variability is less than the inter-laboratory differences. 2010. Published by Elsevier Ltd. All rights reserved.

  14. Uranium hydrogeochemical and stream sediment reconnaissance of the Solomon NTMS quadrangle, Alaska

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Langfeldt, S.L.; Youngquist, C.A.; D'Andrea, R.F. Jr.

    This report presents results of a Hydrogeochemical and Stream Sediment Reconnaissance (HSSR) of the Solomon NTMS quadrangle, Alaska. In addition to this abbreviated data release, more complete data are available to the public in machine-readable form through the Grand Junction Office Information System at Oak Ridge National Laboratory. Presented in this data release are location data, field analyses, and laboratory analyses of several different sample media. For the sake of brevity, many field site observations have not been included in this volume. These data are, however, available on the magnetic tape. Appendices A and B describe the sample media andmore » summarize the analytical results for each medium. The data were subdivided by one of the Los Alamos National Laboratory (LANL) sorting programs of Zinkl and others into groups of stream sediment and stream water samples. For each group which contains a sufficient number of observations, statistical tables, tables of raw data, and 1:1000000 scale maps of pertinent elements have been included in this report. In addition, maps showing results of multivariate statistical analyses have been included. Further information about the HSSR program in general, or about the LANL portion of the program in particular, can be obtained in quarterly or semiannual program progress reports on open-file at DOE's Technical Library in Grand Junction. Information about the field and analytical procedures used by LANL during sample collection and analysis may be found in any HSSR data release prepared by the LANL and will not be included in this report.« less

  15. Building a Laboratory-Scale Biogas Plant and Verifying its Functionality

    NASA Astrophysics Data System (ADS)

    Boleman, Tomáš; Fiala, Jozef; Blinová, Lenka; Gerulová, Kristína

    2011-01-01

    The paper deals with the process of building a laboratory-scale biogas plant and verifying its functionality. The laboratory-scale prototype was constructed in the Department of Safety and Environmental Engineering at the Faculty of Materials Science and Technology in Trnava, of the Slovak University of Technology. The Department has already built a solar laboratory to promote and utilise solar energy, and designed SETUR hydro engine. The laboratory is the next step in the Department's activities in the field of renewable energy sources and biomass. The Department is also involved in the European Union project, where the goal is to upgrade all existed renewable energy sources used in the Department.

  16. Evaluation of analytical performance based on partial order methodology.

    PubMed

    Carlsen, Lars; Bruggemann, Rainer; Kenessova, Olga; Erzhigitov, Erkin

    2015-01-01

    Classical measurements of performances are typically based on linear scales. However, in analytical chemistry a simple scale may be not sufficient to analyze the analytical performance appropriately. Here partial order methodology can be helpful. Within the context described here, partial order analysis can be seen as an ordinal analysis of data matrices, especially to simplify the relative comparisons of objects due to their data profile (the ordered set of values an object have). Hence, partial order methodology offers a unique possibility to evaluate analytical performance. In the present data as, e.g., provided by the laboratories through interlaboratory comparisons or proficiency testings is used as an illustrative example. However, the presented scheme is likewise applicable for comparison of analytical methods or simply as a tool for optimization of an analytical method. The methodology can be applied without presumptions or pretreatment of the analytical data provided in order to evaluate the analytical performance taking into account all indicators simultaneously and thus elucidating a "distance" from the true value. In the present illustrative example it is assumed that the laboratories analyze a given sample several times and subsequently report the mean value, the standard deviation and the skewness, which simultaneously are used for the evaluation of the analytical performance. The analyses lead to information concerning (1) a partial ordering of the laboratories, subsequently, (2) a "distance" to the Reference laboratory and (3) a classification due to the concept of "peculiar points". Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Analysis Of 2H-Evaporator Scale Pot Bottom Sample [HTF-13-11-28H

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oji, L. N.

    2013-07-15

    Savannah River Remediation (SRR) is planning to remove a buildup of sodium aluminosilicate scale from the 2H-evaporator pot by loading and soaking the pot with heated 1.5 M nitric acid solution. Sampling and analysis of the scale material from the 2H evaporator has been performed so that the evaporator can be chemically cleaned beginning July of 2013. Historically, since the operation of the Defense Waste Processing Facility (DWPF), silicon in the DWPF recycle stream combines with aluminum in the typical tank farm supernate to form sodium aluminosilicate scale mineral deposits in the 2H-evaporator pot and gravity drain line. The 2H-evaporatormore » scale samples analyzed by Savannah River National Laboratory (SRNL) came from the bottom cone sections of the 2H-evaporator pot. The sample holder from the 2H-evaporator wall was virtually empty and was not included in the analysis. It is worth noting that after the delivery of these 2H-evaporator scale samples to SRNL for the analyses, the plant customer determined that the 2H evaporator could be operated for additional period prior to requiring cleaning. Therefore, there was no need for expedited sample analysis as was presented in the Technical Task Request. However, a second set of 2H evaporator scale samples were expected in May of 2013, which would need expedited sample analysis. X-ray diffraction analysis (XRD) confirmed the bottom cone section sample from the 2H-evaporator pot consisted of nitrated cancrinite, (a crystalline sodium aluminosilicate solid), clarkeite and uranium oxide. There were also mercury compound XRD peaks which could not be matched and further X-ray fluorescence (XRF) analysis of the sample confirmed the existence of elemental mercury or mercuric oxide. On ''as received'' basis, the scale contained an average of 7.09E+00 wt % total uranium (n = 3; st.dev. = 8.31E-01 wt %) with a U-235 enrichment of 5.80E-01 % (n = 3; st.dev. = 3.96E-02 %). The measured U-238 concentration was 7.05E+00 wt % (n=3, st. dev. = 8.25E-01 wt %). Analyses results for Pu-238 and Pu-239, and Pu-241 are 7.06E-05 {+-} 7.63E-06 wt %, 9.45E-04 {+-} 3.52E-05 wt %, and <2.24E-06 wt %, respectively. These results are provided so that SRR can calculate the equivalent uranium-235 concentrations for the NCSA. Because this 2H evaporator pot bottom scale sample contained a significant amount of elemental mercury (11.7 wt % average), it is recommended that analysis for mercury be included in future Technical Task Requests on 2H evaporator sample analysis at SRNL. Results confirm that the uranium contained in the scale remains depleted with respect to natural uranium. SRNL did not calculate an equivalent U-235 enrichment, which takes into account other fissionable isotopes U-233, Pu-239 and Pu-241.« less

  18. Practices for Identifying and Rejecting Hemolyzed Specimens Are Highly Variable in Clinical Laboratories.

    PubMed

    Howanitz, Peter J; Lehman, Christopher M; Jones, Bruce A; Meier, Frederick A; Horowitz, Gary L

    2015-08-01

    Hemolysis is an important clinical laboratory quality attribute that influences result reliability. To determine hemolysis identification and rejection practices occurring in clinical laboratories. We used the College of American Pathologists Survey program to distribute a Q-Probes-type questionnaire about hemolysis practices to Chemistry Survey participants. Of 3495 participants sent the questionnaire, 846 (24%) responded. In 71% of 772 laboratories, the hemolysis rate was less than 3.0%, whereas in 5%, it was 6.0% or greater. A visual scale, an instrument scale, and combination of visual and instrument scales were used to identify hemolysis in 48%, 11%, and 41% of laboratories, respectively. A picture of the hemolysis level was used as an aid to technologists' visual interpretation of hemolysis levels in 40% of laboratories. In 7.0% of laboratories, all hemolyzed specimens were rejected; in 4% of laboratories, no hemolyzed specimens were rejected; and in 88% of laboratories, some specimens were rejected depending on hemolysis levels. Participants used 69 different terms to describe hemolysis scales, with 21 terms used in more than 10 laboratories. Slight and moderate were the terms used most commonly. Of 16 different cutoffs used to reject hemolyzed specimens, moderate was the most common, occurring in 30% of laboratories. For whole blood electrolyte measurements performed in 86 laboratories, 57% did not evaluate the presence of hemolysis, but for those that did, the most common practice in 21 laboratories (24%) was centrifuging and visually determining the presence of hemolysis in all specimens. Hemolysis practices vary widely. Standard assessment and consistent reporting are the first steps in reducing interlaboratory variability among results.

  19. A comparison of relative toxicity rankings by some small-scale laboratory tests

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Cumming, H. J.

    1977-01-01

    Small-scale laboratory tests for fire toxicity, suitable for use in the average laboratory hood, are needed for screening and ranking materials on the basis of relative toxicity. The performance of wool, cotton, and aromatic polyamide under several test procedures is presented.

  20. Exploring the remote sensing of foliar biochemical concentrations with AVIRIS data

    NASA Technical Reports Server (NTRS)

    Smith, Geoffrey M.; Curran, Paul J.

    1992-01-01

    Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data shows promise for the estimation of foliar biochemical concentrations at the scale of the canopy. There are, however, several problems associated with the use of AVIRIS data in this way and these are detailed in recent Plant Biochemical Workshop Report. The research reported was concentrated upon three of these problems: field sampling of forest canopies, wet laboratory assay of foliar chemicals, and the visualization of AVIRIS data.

  1. (Bio-)remediation of VCHC contaminants in a Technosol under unsaturated conditions.

    PubMed

    Baumgarten, W; Fleige, H; Peth, S; Horn, R

    2013-07-01

    The remediation of dense non-aqueous phase liquids has always been a concern of both public and scientific interest groups. In this research work a modified physical concept of (bio)remediation of a volatile chlorinated hydrocarbon (VCHC) contamination was elaborated under laboratory conditions and modeled with HYDRUS-2D. In field dechlorination is influenced by both physicochemical and hydraulic properties of the substrate, e.g. texture, pore size distribution, pore liquid characteristics, e.g. viscosity, pH, surface tension, and dependent on the degree of saturation of the vadose zone. Undisturbed soil cores (100 cm³) were sampled from a Spolic Technosol. Considering hydraulic properties and functions, unsaturated percolation was performed with vertically and horizontally structured samples. VCHC concentrations were calculated prior, during, and after each percolation cycle. According to laboratory findings, microemulsion showed the most efficient results with regard to flow behavior in the unsaturated porous media and its accessibility for bacteria as nutrient. The efficiency of VCHC remediation could be increased by the application of a modified pump-and-treat system: the injection of bacteria Dehalococcoides ethanogenes with microemulsion, and extraction at a constant matric potential level of -6 kPa. Achieved data was used for HYDRUS-2D simulations, modeling in situ conditions, demonstrating the practical relevance (field scale) of performed unsaturated percolation (core scale), and in order to exclude capillary barrier effects.

  2. Experimental and Numerical Observations of Hydrate Reformation during Depressurization in a Core-Scale Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seol, Yongkoo; Myshakin, Evgeniy

    2011-01-01

    Gas hydrate has been predicted to reform around a wellbore during depressurization-based gas production from gas hydrate-bearing reservoirs. This process has an adverse effect on gas production rates and it requires time and sometimes special measures to resume gas flow to producing wells. Due to lack of applicable field data, laboratory scale experiments remain a valuable source of information to study hydrate reformation. In this work, we report laboratory experiments and complementary numerical simulations executed to investigate the hydrate reformation phenomenon. Gas production from a pressure vessel filled with hydrate-bearing sand was induced by depressurization with and without heat fluxmore » through the boundaries. Hydrate decomposition was monitored with a medical X-ray CT scanner and pressure and temperature measurements. CT images of the hydrate-bearing sample were processed to provide 3-dimensional data of heterogeneous porosity and phase saturations suitable for numerical simulations. In the experiments, gas hydrate reformation was observed only in the case of no-heat supply from surroundings, a finding consistent with numerical simulation. By allowing gas production on either side of the core, numerical simulations showed that initial hydrate distribution patterns affect gas distribution and flow inside the sample. This is a direct consequence of the heterogeneous pore network resulting in varying hydraulic properties of the hydrate-bearing sediment.« less

  3. Fumigation of a laboratory-scale HVAC system with hydrogen peroxide for decontamination following a biological contamination incident.

    PubMed

    Meyer, K M; Calfee, M W; Wood, J P; Mickelsen, L; Attwood, B; Clayton, M; Touati, A; Delafield, R

    2014-03-01

    To evaluate hydrogen peroxide vapour (H2 O2 ) for its ability to inactivate Bacillus spores within a laboratory-scale heating, ventilation and air-conditioning (HVAC) duct system. Experiments were conducted in a closed-loop duct system, constructed of either internally lined or unlined galvanized metal. Bacterial spores were aerosol-deposited onto 18-mm-diameter test material coupons and strategically placed at several locations within the duct environment. Various concentrations of H2 O2 and exposure times were evaluated to determine the sporicidal efficacy and minimum exposure needed for decontamination. For the unlined duct, high variability was observed in the recovery of spores between sample locations, likely due to complex, unpredictable flow patterns within the ducts. In comparison, the lined duct exhibited a significant desorption of the H2 O2 following the fumigant dwell period and thus resulted in complete decontamination at all sampling locations. These findings suggest that decontamination of Bacillus spore-contaminated unlined HVAC ducts by hydrogen peroxide fumigation may require more stringent conditions (higher concentrations, longer dwell duration) than internally insulated ductwork. These data may help emergency responders when developing remediation plans during building decontamination. © 2013 The Society for Applied Microbiology This article has been contributed to by US Government employees and their work is in the public domain in the USA.

  4. Achieving across-laboratory replicability in psychophysical scaling

    PubMed Central

    Ward, Lawrence M.; Baumann, Michael; Moffat, Graeme; Roberts, Larry E.; Mori, Shuji; Rutledge-Taylor, Matthew; West, Robert L.

    2015-01-01

    It is well known that, although psychophysical scaling produces good qualitative agreement between experiments, precise quantitative agreement between experimental results, such as that routinely achieved in physics or biology, is rarely or never attained. A particularly galling example of this is the fact that power function exponents for the same psychological continuum, measured in different laboratories but ostensibly using the same scaling method, magnitude estimation, can vary by a factor of three. Constrained scaling (CS), in which observers first learn a standardized meaning for a set of numerical responses relative to a standard sensory continuum and then make magnitude judgments of other sensations using the learned response scale, has produced excellent quantitative agreement between individual observers’ psychophysical functions. Theoretically it could do the same for across-laboratory comparisons, although this needs to be tested directly. We compared nine different experiments from four different laboratories as an example of the level of across experiment and across-laboratory agreement achievable using CS. In general, we found across experiment and across-laboratory agreement using CS to be significantly superior to that typically obtained with conventional magnitude estimation techniques, although some of its potential remains to be realized. PMID:26191019

  5. Solid-phase extraction combined with high-performance liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry analysis of pesticides in water: method performance and application in a reconnaissance survey of residues in drinking water in Greater Cairo, Egypt.

    PubMed

    Potter, Thomas L; Mohamed, Mahmoud A; Ali, Hannah

    2007-01-24

    Monitoring of water resources for pesticide residues is often needed to ensure that pesticide use does not adversely impact the quality of public water supplies or the environment. In many rural areas and throughout much of the developing world, monitoring is often constrained by lack of testing facilities; thus, collection of samples and shipment to centralized laboratories for analysis is required. The portability, ease of use, and potential to enhance analyte stability make solid-phase extraction (SPE) an attractive technique for handling water samples prior to their shipment. We describe performance of an SPE method targeting a structurally diverse mixture of 25 current-use pesticides and two common degradates in samples of raw and filtered drinking water collected in Greater Cairo, Egypt. SPE was completed in a field laboratory in Egypt, and cartridges were shipped to the United States for elution and high-performance liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry analysis. Quantitative and reproducible recovery of 23 of 27 compounds (average = 96%; percent relative standard deviation = 21%) from matrix spikes (1 microg L-1 per component) prepared in the field and from deionized water fortified similarly in the analytical laboratory was obtained. Concurrent analysis of unspiked samples identified four parent compounds and one degradate in drinking water samples. No significant differences were observed between raw and filtered samples. Residue levels in all cases were below drinking water and "harm to aquatic-life" thresholds, indicating that human and ecological risks of pesticide contamination were relatively small; however, the study was limited in scale and scope. Further monitoring is needed to define spatial and temporal variation in residue concentrations. The study has demonstrated the feasibility of performing studies of this type using SPE to extract and preserve samples in the field. The approach should be broadly applicable in many settings.

  6. U.S. Geological Survey Standard Reference Sample Project: Performance Evaluation of Analytical Laboratories

    USGS Publications Warehouse

    Long, H. Keith; Daddow, Richard L.; Farrar, Jerry W.

    1998-01-01

    Since 1962, the U.S. Geological Survey (USGS) has operated the Standard Reference Sample Project to evaluate the performance of USGS, cooperator, and contractor analytical laboratories that analyze chemical constituents of environmental samples. The laboratories are evaluated by using performance evaluation samples, called Standard Reference Samples (SRSs). SRSs are submitted to laboratories semi-annually for round-robin laboratory performance comparison purposes. Currently, approximately 100 laboratories are evaluated for their analytical performance on six SRSs for inorganic and nutrient constituents. As part of the SRS Project, a surplus of homogeneous, stable SRSs is maintained for purchase by USGS offices and participating laboratories for use in continuing quality-assurance and quality-control activities. Statistical evaluation of the laboratories results provides information to compare the analytical performance of the laboratories and to determine possible analytical deficiences and problems. SRS results also provide information on the bias and variability of different analytical methods used in the SRS analyses.

  7. Form and function in hillslope hydrology: in situ imaging and characterization of flow-relevant structures

    NASA Astrophysics Data System (ADS)

    Jackisch, Conrad; Angermann, Lisa; Allroggen, Niklas; Sprenger, Matthias; Blume, Theresa; Tronicke, Jens; Zehe, Erwin

    2017-07-01

    The study deals with the identification and characterization of rapid subsurface flow structures through pedo- and geo-physical measurements and irrigation experiments at the point, plot and hillslope scale. Our investigation of flow-relevant structures and hydrological responses refers to the general interplay of form and function, respectively. To obtain a holistic picture of the subsurface, a large set of different laboratory, exploratory and experimental methods was used at the different scales. For exploration these methods included drilled soil core profiles, in situ measurements of infiltration capacity and saturated hydraulic conductivity, and laboratory analyses of soil water retention and saturated hydraulic conductivity. The irrigation experiments at the plot scale were monitored through a combination of dye tracer, salt tracer, soil moisture dynamics, and 3-D time-lapse ground penetrating radar (GPR) methods. At the hillslope scale the subsurface was explored by a 3-D GPR survey. A natural storm event and an irrigation experiment were monitored by a dense network of soil moisture observations and a cascade of 2-D time-lapse GPR trenches. We show that the shift between activated and non-activated state of the flow paths is needed to distinguish structures from overall heterogeneity. Pedo-physical analyses of point-scale samples are the basis for sub-scale structure inference. At the plot and hillslope scale 3-D and 2-D time-lapse GPR applications are successfully employed as non-invasive means to image subsurface response patterns and to identify flow-relevant paths. Tracer recovery and soil water responses from irrigation experiments deliver a consistent estimate of response velocities. The combined observation of form and function under active conditions provides the means to localize and characterize the structures (this study) and the hydrological processes (companion study Angermann et al., 2017, this issue).

  8. Fully Automated Sample Preparation for Ultrafast N-Glycosylation Analysis of Antibody Therapeutics.

    PubMed

    Szigeti, Marton; Lew, Clarence; Roby, Keith; Guttman, Andras

    2016-04-01

    There is a growing demand in the biopharmaceutical industry for high-throughput, large-scale N-glycosylation profiling of therapeutic antibodies in all phases of product development, but especially during clone selection when hundreds of samples should be analyzed in a short period of time to assure their glycosylation-based biological activity. Our group has recently developed a magnetic bead-based protocol for N-glycosylation analysis of glycoproteins to alleviate the hard-to-automate centrifugation and vacuum-centrifugation steps of the currently used protocols. Glycan release, fluorophore labeling, and cleanup were all optimized, resulting in a <4 h magnetic bead-based process with excellent yield and good repeatability. This article demonstrates the next level of this work by automating all steps of the optimized magnetic bead-based protocol from endoglycosidase digestion, through fluorophore labeling and cleanup with high-throughput sample processing in 96-well plate format, using an automated laboratory workstation. Capillary electrophoresis analysis of the fluorophore-labeled glycans was also optimized for rapid (<3 min) separation to accommodate the high-throughput processing of the automated sample preparation workflow. Ultrafast N-glycosylation analyses of several commercially relevant antibody therapeutics are also shown and compared to their biosimilar counterparts, addressing the biological significance of the differences. © 2015 Society for Laboratory Automation and Screening.

  9. Application and evaluation of scale dissolver treatments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fielder, G.D.

    1994-12-31

    In order to provide an improved basis for the design of barium sulfate scale dissolver treatments both laboratory testing and monitoring of field applications were carried out. The deleterious effects of mixing produced water with dissolver prior to contacting scale are shown. Increasing total dissolved solids (TDS) levels can reduce dissolution depending upon temperature. Precomplexation with divalent cations reduces the capacity of the dissolver to solubilize solid scales. Magnesium may adversely affect dissolver performance at elevated temperatures. Several oil and gas wells were closely monitored during initial flowback after treatment. Samples were collected on a frequent basis and analyzed formore » pH, dissolver content, chlorides and various cations. The resulting data were used to construct flowback profiles for evaluation of the treatments. Evidence of scale dissolution is presented. The presence of an incompatible flush brine was discovered in one case and possible reverse order of addition of preflush and dissolver in another. The importance of establishing and following treatment procedures is briefly discussed.« less

  10. COMPARISON OF TWO METHODS FOR THE ISOLATION OF SALMONELLAE FROM IMPORTED FOODS.

    PubMed

    TAYLOR, W I; HOBBS, B C; SMITH, M E

    1964-01-01

    Two methods for the detection of salmonellae in foods were compared in 179 imported meat and egg samples. The number of positive samples and replications, and the number of strains and kinds of serotypes were statistically comparable by both the direct enrichment method of the Food Hygiene Laboratory in England, and the pre-enrichment method devised for processed foods in the United States. Boneless frozen beef, veal, and horsemeat imported from five countries for consumption in England were found to have salmonellae present in 48 of 116 (41%) samples. Dried egg products imported from three countries were observed to have salmonellae in 10 of 63 (16%) samples. The high incidence of salmonellae isolated from imported foods illustrated the existence of an international health hazard resulting from the continuous introduction of exogenous strains of pathogenic microorganisms on a large scale.

  11. Laboratory study of adsorption and deliquescence on the surface of Mars

    NASA Astrophysics Data System (ADS)

    Nikolakakos, George; Whiteway, James A.

    2018-07-01

    A sample of the zeolitic mineral chabazite was subjected to a range of water vapor pressures and temperatures found on present day Mars. Laser Raman scattering was applied to detect the relative amounts of water and carbon dioxide adsorbed by the sample. Results show that zeolites are capable of adsorbing water from the atmosphere on diurnal time scales and that Raman scattering spectroscopy provides a promising method for detecting this process during a landed mission. When the water vapor pressure and temperature were sufficiently low, the zeolite sample also adsorbed carbon dioxide, resulting in the simultaneous adsorption of water and carbon dioxide on the surface mineral grains. Additional experiments were carried out using a mixture of magnesium perchlorate and chabazite. The sample of mixed surface material remained visually unchanged during water adsorption, but was found to darken during deliquescence.

  12. A soil sampling intercomparison exercise for the ALMERA network.

    PubMed

    Belli, Maria; de Zorzi, Paolo; Sansone, Umberto; Shakhashiro, Abduhlghani; Gondin da Fonseca, Adelaide; Trinkl, Alexander; Benesch, Thomas

    2009-11-01

    Soil sampling and analysis for radionuclides after an accidental or routine release is a key factor for the dose calculation to members of the public, and for the establishment of possible countermeasures. The IAEA organized for selected laboratories of the ALMERA (Analytical Laboratories for the Measurement of Environmental Radioactivity) network a Soil Sampling Intercomparison Exercise (IAEA/SIE/01) with the objective of comparing soil sampling procedures used by different laboratories. The ALMERA network is a world-wide network of analytical laboratories located in IAEA member states capable of providing reliable and timely analysis of environmental samples in the event of an accidental or intentional release of radioactivity. Ten ALMERA laboratories were selected to participate in the sampling exercise. The soil sampling intercomparison exercise took place in November 2005 in an agricultural area qualified as a "reference site", aimed at assessing the uncertainties associated with soil sampling in agricultural, semi-natural, urban and contaminated environments and suitable for performing sampling intercomparison. In this paper, the laboratories sampling performance were evaluated.

  13. Characterizing regional soil mineral composition using spectroscopyand geostatistics

    USGS Publications Warehouse

    Mulder, V.L.; de Bruin, S.; Weyermann, J.; Kokaly, Raymond F.; Schaepman, M.E.

    2013-01-01

    This work aims at improving the mapping of major mineral variability at regional scale using scale-dependent spatial variability observed in remote sensing data. Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) data and statistical methods were combined with laboratory-based mineral characterization of field samples to create maps of the distributions of clay, mica and carbonate minerals and their abundances. The Material Identification and Characterization Algorithm (MICA) was used to identify the spectrally-dominant minerals in field samples; these results were combined with ASTER data using multinomial logistic regression to map mineral distributions. X-ray diffraction (XRD)was used to quantify mineral composition in field samples. XRD results were combined with ASTER data using multiple linear regression to map mineral abundances. We testedwhether smoothing of the ASTER data to match the scale of variability of the target sample would improve model correlations. Smoothing was donewith Fixed Rank Kriging (FRK) to represent the mediumand long-range spatial variability in the ASTER data. Stronger correlations resulted using the smoothed data compared to results obtained with the original data. Highest model accuracies came from using both medium and long-range scaled ASTER data as input to the statistical models. High correlation coefficients were obtained for the abundances of calcite and mica (R2 = 0.71 and 0.70, respectively). Moderately-high correlation coefficients were found for smectite and kaolinite (R2 = 0.57 and 0.45, respectively). Maps of mineral distributions, obtained by relating ASTER data to MICA analysis of field samples, were found to characterize major soil mineral variability (overall accuracies for mica, smectite and kaolinite were 76%, 89% and 86% respectively). The results of this study suggest that the distributions of minerals and their abundances derived using FRK-smoothed ASTER data more closely match the spatial variability of soil and environmental properties at regional scale.

  14. Analysis Of 2H-Evaporator Scale Wall [HTF-13-82] And Pot Bottom [HTF-13-77] Samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oji, L. N.

    2013-09-11

    Savannah River Remediation (SRR) is planning to remove a buildup of sodium aluminosilicate scale from the 2H-evaporator pot by loading and soaking the pot with heated 1.5 M nitric acid solution. Sampling and analysis of the scale material has been performed so that uranium and plutonium isotopic analysis can be input into a Nuclear Criticality Safety Assessment (NCSA) for scale removal by chemical cleaning. Historically, since the operation of the Defense Waste Processing Facility (DWPF), silicon in the DWPF recycle stream combines with aluminum in the typical tank farm supernate to form sodium aluminosilicate scale mineral deposits in the 2H-evaporatormore » pot and gravity drain line. The 2H-evaporator scale samples analyzed by Savannah River National Laboratory (SRNL) came from two different locations within the evaporator pot; the bottom cone sections of the 2H-evaporator pot [Sample HTF-13-77] and the wall 2H-evaporator [sample HTF-13-82]. X-ray diffraction analysis (XRD) confirmed that both the 2H-evaporator pot scale and the wall samples consist of nitrated cancrinite (a crystalline sodium aluminosilicate solid) and clarkeite (a uranium oxyhydroxide mineral). On ''as received'' basis, the bottom pot section scale sample contained an average of 2.59E+00 {+-} 1.40E-01 wt % total uranium with a U-235 enrichment of 6.12E-01 {+-} 1.48E-02 %, while the wall sample contained an average of 4.03E+00 {+-} 9.79E-01 wt % total uranium with a U-235 enrichment of 6.03E-01% {+-} 1.66E-02 wt %. The bottom pot section scale sample analyses results for Pu-238, Pu-239, and Pu-241 are 3.16E-05 {+-} 5.40E-06 wt %, 3.28E-04 {+-} 1.45E-05 wt %, and <8.80E-07 wt %, respectively. The evaporator wall scale samples analysis values for Pu-238, Pu-239, and Pu-241 averages 3.74E-05 {+-} 6.01E-06 wt %, 4.38E-04 {+-} 5.08E-05 wt %, and <1.38E-06 wt %, respectively. The Pu-241 analyses results, as presented, are upper limit values. For these two evaporator scale samples obtained at two different locations within the evaporator pot the major radioactive components (on a mass basis) in the additional radionuclide analyses were Sr-90, Cs-137 Np-237, Pu-239/240 and Th-232. Small quantities of americium and curium were detected in the blanks used for Am/Cm method for these radionuclides. These trace radionuclide amounts are assumed to come from airborne contamination in the shielded cells drying or digestion oven, which has been replaced. Therefore, the Am/Cm results, as presented, may be higher than the true Am/Cm values for these samples. These results are provided so that SRR can calculate the equivalent uranium-235 concentrations for the NCSA. Results confirm that the uranium contained in the scale remains depleted with respect to natural uranium. SRNL did not calculate an equivalent U-235 enrichment, which takes into account other fissionable isotopes U-233, Pu-239 and Pu-241. The applicable method for calculation of equivalent U-235 will be determined in the NCSA. With a few exceptions, a comparison of select radionuclides measurements from this 2013 2H evaporator scale characterization (pot bottom and wall scale samples) with those measurements for the same radionuclides in the 2010 2H evaporator scale analysis shows that the radionuclide analysis for both years are fairly comparable; the analyses results are about the same order of magnitude.« less

  15. Predictive modelling of flow in a two-dimensional intermediate-scale, heterogeneous porous media

    USGS Publications Warehouse

    Barth, Gilbert R.; Hill, M.C.; Illangasekare, T.H.; Rajaram, H.

    2000-01-01

    To better understand the role of sedimentary structures in flow through porous media, and to determine how small-scale laboratory-measured values of hydraulic conductivity relate to in situ values this work deterministically examines flow through simple, artificial structures constructed for a series of intermediate-scale (10 m long), two-dimensional, heterogeneous, laboratory experiments. Nonlinear regression was used to determine optimal values of in situ hydraulic conductivity, which were compared to laboratory-measured values. Despite explicit numerical representation of the heterogeneity, the optimized values were generally greater than the laboratory-measured values. Discrepancies between measured and optimal values varied depending on the sand sieve size, but their contribution to error in the predicted flow was fairly consistent for all sands. Results indicate that, even under these controlled circumstances, laboratory-measured values of hydraulic conductivity need to be applied to models cautiously.To better understand the role of sedimentary structures in flow through porous media, and to determine how small-scale laboratory-measured values of hydraulic conductivity relate to in situ values this work deterministically examines flow through simple, artificial structures constructed for a series of intermediate-scale (10 m long), two-dimensional, heterogeneous, laboratory experiments. Nonlinear regression was used to determine optimal values of in situ hydraulic conductivity, which were compared to laboratory-measured values. Despite explicit numerical representation of the heterogeneity, the optimized values were generally greater than the laboratory-measured values. Discrepancies between measured and optimal values varied depending on the sand sieve size, but their contribution to error in the predicted flow was fairly consistent for all sands. Results indicate that, even under these controlled circumstances, laboratory-measured values of hydraulic conductivity need to be applied to models cautiously.

  16. Laboratory Activity on Sample Handling and Maintaining a Laboratory Notebook through Simple pH Measurements

    ERIC Educational Resources Information Center

    Erdmann, Mitzy A.; March, Joe L.

    2016-01-01

    Sample handling and laboratory notebook maintenance are necessary skills but can seem abstract if not presented to students in context. An introductory exercise focusing on proper sample handling, data collection and laboratory notebook keeping for the general chemistry laboratory was developed to emphasize the importance of keeping an accurate…

  17. Application of simultaneous saccharification and fermentation (SSF) from viscosity reducing of raw sweet potato for bioethanol production at laboratory, pilot and industrial scales.

    PubMed

    Zhang, Liang; Zhao, Hai; Gan, Mingzhe; Jin, Yanlin; Gao, Xiaofeng; Chen, Qian; Guan, Jiafa; Wang, Zhongyan

    2011-03-01

    The aim of this work was to research a bioprocess for bioethanol production from raw sweet potato by Saccharomyces cerevisiae at laboratory, pilot and industrial scales. The fermentation mode, inoculum size and pressure from different gases were determined in laboratory. The maximum ethanol concentration, average ethanol productivity rate and yield of ethanol after fermentation in laboratory scale (128.51 g/L, 4.76 g/L/h and 91.4%) were satisfactory with small decrease at pilot scale (109.06 g/L, 4.89 g/L/h and 91.24%) and industrial scale (97.94 g/L, 4.19 g/L/h and 91.27%). When scaled up, the viscosity caused resistance to fermentation parameters, 1.56 AUG/g (sweet potato mash) of xylanase decreased the viscosity from approximately 30000 to 500 cp. Overall, sweet potato is a attractive feedstock for be bioethanol production from both the economic standpoints and environmentally friendly. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Integrating exhaled breath diagnostics by disease-sniffing dogs with instrumental laboratory analysis.

    PubMed

    Pleil, Joachim; Giese, Roger

    2017-09-07

    Dogs have been studied for many years as a medical diagnostic tool to detect a pre-clinical disease state by sniffing emissions directly from a human or an in vitro biological sample. Some of the studies report high sensitivity and specificity in blinded case-control studies. However, in these studies it is completely unknown as to which suites of chemicals the dogs detect and how they ultimately interpret this information amidst confounding background odors. Herein, we consider the advantages and challenges of canine olfaction for early (meaningful) detection of cancer, and propose an experimental concept to narrow the molecular signals used by the dog for sample classification to laboratory-based instrumental analysis. This serves two purposes; first, in contrast to dogs, analytical methods could be quickly up-scaled for high throughput sampling. Second, the knowledge gained from identifying probative chemicals could be helpful in learning more about biochemical pathways and disease progression. We focus on exhaled breath aerosol, arguing that the semi-volatile fraction should be given more attention. Ultimately, we conclude that the interaction between dog-based and instrument-based research will be mutually beneficial and accelerate progress towards early detection of cancer by breath analysis.

  19. Crystallization of Calcium Carbonate in a Large Scale Field Study

    NASA Astrophysics Data System (ADS)

    Ueckert, Martina; Wismeth, Carina; Baumann, Thomas

    2017-04-01

    The long term efficiency of geothermal facilities and aquifer thermal energy storage in the carbonaceous Malm aquifer in the Bavarian Molasse Basin is seriously affected by precipitations of carbonates. This is mainly caused by pressure and temperature changes leading to oversaturation during production. Crystallization starts with polymorphic nuclei of calcium carbonate and is often described as diffusion-reaction controlled. Here, calcite crystallization is favoured by high concentration gradients while aragonite crystallization is occurring at high reaction rates. The factors affecting the crystallization processes have been described for simplified, well controlled laboratory experiments, the knowledge about the behaviour in more complex natural systems is still limited. The crystallization process of the polymorphic forms of calcium carbonate were investigated during a heat storage test at our test site in the eastern part of the Bavarian Molasse Basin. Complementary laboratory experiments in an autoclave were run. Both, field and laboratory experiments were conducted with carbonaceous tap water. Within the laboratory experiments additionally ultra pure water was used. To avoid precipitations of the tap water, a calculated amount of {CO_2} was added prior to heating the water from 45 - 110°C (laboratory) resp. 65 - 110°C (field). A total water volume of 0.5 L (laboratory) resp. 1 L (field) was immediately sampled and filtrated through 10 - 0.1

  20. Importance of Public-Private Partnerships: Strengthening Laboratory Medicine Systems and Clinical Practice in Africa.

    PubMed

    Shrivastava, Ritu; Gadde, Renuka; Nkengasong, John N

    2016-04-15

    After the launch of the US President's Emergency Plan for AIDS Relief in 2003, it became evident that inadequate laboratory systems and services would severely limit the scale-up of human immunodeficiency virus infection prevention, care, and treatment programs. Thus, the Office of the US Global AIDS Coordinator, Centers for Disease Control and Prevention, and Becton, Dickinson and Company developed a public-private partnership (PPP). Between October 2007 and July 2012, the PPP combined the competencies of the public and private sectors to boost sustainable laboratory systems and develop workforce skills in 4 African countries. Key accomplishments of the initiative include measurable and scalable outcomes to strengthen national capacities to build technical skills, develop sample referral networks, map disease prevalence, support evidence-based health programming, and drive continuous quality improvement in laboratories. This report details lessons learned from our experience and a series of recommendations on how to achieve successful PPPs. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  1. Baccalaureate nursing students' perspectives of peer tutoring in simulation laboratory, a Q methodology study.

    PubMed

    Li, Ting; Petrini, Marcia A; Stone, Teresa E

    2018-02-01

    The study aim was to identify the perceived perspectives of baccalaureate nursing students toward the peer tutoring in the simulation laboratory. Insight into the nursing students' experiences and baseline data related to their perception of peer tutoring will assist to improve nursing education. Q methodology was applied to explore the students' perspectives of peer tutoring in the simulation laboratory. A convenience P-sample of 40 baccalaureate nursing students was used. Fifty-eight selected Q statements from each participant were classified into the shape of a normal distribution using an 11-point bipolar scale form with a range from -5 to +5. PQ Method software analyzed the collected data. Three discrete factors emerged: Factor I ("Facilitate or empower" knowledge acquisition), Factor II ("Safety Net" Support environment), and Factor III ("Mentoring" learn how to learn). The findings of this study support and indicate that peer tutoring is an effective supplementary strategy to promote baccalaureate students' knowledge acquisition, establishing a supportive safety net and facilitating their abilities to learn in the simulation laboratory. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Interlaboratory Study Characterizing a Yeast Performance Standard for Benchmarking LC-MS Platform Performance*

    PubMed Central

    Paulovich, Amanda G.; Billheimer, Dean; Ham, Amy-Joan L.; Vega-Montoto, Lorenzo; Rudnick, Paul A.; Tabb, David L.; Wang, Pei; Blackman, Ronald K.; Bunk, David M.; Cardasis, Helene L.; Clauser, Karl R.; Kinsinger, Christopher R.; Schilling, Birgit; Tegeler, Tony J.; Variyath, Asokan Mulayath; Wang, Mu; Whiteaker, Jeffrey R.; Zimmerman, Lisa J.; Fenyo, David; Carr, Steven A.; Fisher, Susan J.; Gibson, Bradford W.; Mesri, Mehdi; Neubert, Thomas A.; Regnier, Fred E.; Rodriguez, Henry; Spiegelman, Cliff; Stein, Stephen E.; Tempst, Paul; Liebler, Daniel C.

    2010-01-01

    Optimal performance of LC-MS/MS platforms is critical to generating high quality proteomics data. Although individual laboratories have developed quality control samples, there is no widely available performance standard of biological complexity (and associated reference data sets) for benchmarking of platform performance for analysis of complex biological proteomes across different laboratories in the community. Individual preparations of the yeast Saccharomyces cerevisiae proteome have been used extensively by laboratories in the proteomics community to characterize LC-MS platform performance. The yeast proteome is uniquely attractive as a performance standard because it is the most extensively characterized complex biological proteome and the only one associated with several large scale studies estimating the abundance of all detectable proteins. In this study, we describe a standard operating protocol for large scale production of the yeast performance standard and offer aliquots to the community through the National Institute of Standards and Technology where the yeast proteome is under development as a certified reference material to meet the long term needs of the community. Using a series of metrics that characterize LC-MS performance, we provide a reference data set demonstrating typical performance of commonly used ion trap instrument platforms in expert laboratories; the results provide a basis for laboratories to benchmark their own performance, to improve upon current methods, and to evaluate new technologies. Additionally, we demonstrate how the yeast reference, spiked with human proteins, can be used to benchmark the power of proteomics platforms for detection of differentially expressed proteins at different levels of concentration in a complex matrix, thereby providing a metric to evaluate and minimize preanalytical and analytical variation in comparative proteomics experiments. PMID:19858499

  3. Triolein embedded cellulose acetate membrane as a tool to evaluate sequestration of PAHs in lake sediment core at large temporal scale.

    PubMed

    Tao, Yuqiang; Xue, Bin; Yao, Shuchun; Deng, Jiancai; Gui, Zhifan

    2012-04-03

    Although numerous studies have addressed sequestration of hydrophobic organic compounds (HOCs) in laboratory, little attention has been paid to its evaluation method in field at large temporal scale. A biomimetic tool, triolein embedded cellulose acetate membrane (TECAM), was therefore tested to evaluate sequestration of six PAHs with various hydrophobicity in a well-dated sediment core sampled from Nanyi Lake, China. Properties of sediment organic matter (OM) varying with aging time dominated the sequestration of PAHs in the sediment core. TECAM-sediment accumulation factors (MSAFs) of the PAHs declined with aging time, and significantly correlated with the corresponding biota-sediment accumulation factors (BSAFs) for gastropod (Bellamya aeruginosa) simultaneously incubated in the same sediment slices. Sequestration rates of the PAHs in the sediment core evaluated by TECAM were much lower than those obtained from laboratory study. The relationship between relative availability for TECAM (MSAF(t)/MSAF(0)) and aging time followed the first order exponential decay model. MSAF(t)/MSAF(0) was well-related to the minor changes of the properties of OM varying with aging time. Compared with chemical extraction, sequestration reflected by TECAM was much closer to that by B. aeruginosa. In contrast to B. aeruginosa, TECAM could avoid metabolism and the influences from feeding and other behaviors of organisms, and it is much easier to deploy and ready in laboratory. Hence TECAM provides an effective and convenient way to study sequestration of PAHs and probably other HOCs in field at large temporal scale.

  4. A contribution to reduce sampling variability in the evaluation of deoxynivalenol contamination of organic wheat grain.

    PubMed

    Hallier, Arnaud; Celette, Florian; Coutarel, Julie; David, Christophe

    2013-01-01

    Fusarium head blight caused by different varieties of Fusarium species is one of the major serious worldwide diseases found in wheat production. It is therefore important to be able to quantify the deoxynivalenol concentration in wheat. Unfortunately, in mycotoxin quantification, due to the uneven distribution of mycotoxins within the initial lot, it is difficult, or even impossible, to obtain a truly representative analytical sample. In previous work we showed that the sampling step most responsible for variability was grain sampling. In this paper, it is more particularly the step scaling down from a laboratory sample of some kilograms to an analytical sample of a few grams that is investigated. The naturally contaminated wheat lot was obtained from an organic field located in the southeast of France (Rhône-Alpes) from the year 2008-2009 cropping season. The deoxynivalenol level was found to be 50.6 ± 2.3 ng g⁻¹. Deoxynivalenol was extracted with a acetonitrile-water mix and quantified by gas chromatography-electron capture detection (GC-ECD). Three different grain sampling techniques were tested to obtain analytical samples: a technique based on manually homogenisation and division, a second technique based on the use of a rotating shaker and a third on the use of compressed air. Both the rotating shaker and the compressed air techniques enabled a homogeneous laboratory sample to be obtained, from which representative analytical samples could be taken. Moreover, the techniques did away with many repetitions and grinding. This study, therefore, contributes to sampling variability reduction in the evaluation of deoxynivalenol contamination of organic wheat grain, and then, at a reasonable cost.

  5. Tribological Properties of CrAlN and TiN Coatings Tested in Nano- and Micro-scale Laboratory Wear Tests

    NASA Astrophysics Data System (ADS)

    Hong, Ling; Bian, Guangdong; Hu, Shugen; Wang, Linlin; Dacosta, Herbert

    2015-07-01

    We investigated the tribological properties of CrAlN and TiN coatings produced by electron beam plasma-assisted physical vapor deposition by nano- and micro-scale wear tests. For comparison, we also conducted nano-indentation, nano-scanning wear tests, and pin-on-disk tribotests on uncoated M2 steel. The results indicate that, after nano-scale sliding tests against diamond indenter and pin-on-disk tests against ceramic alumina counterface pins, the CrAlN coating presents superior abrasive wear resistance compared to the TiN-coated and uncoated M2 steel samples. Against aluminum counterface, aluminum is more prone to attach on the CrAlN coating surface compared to TiN coating, but no apparent adhesive wear was observed, which has occurred on the TiN coating.

  6. A Note on the Fractal Behavior of Hydraulic Conductivity and Effective Porosity for Experimental Values in a Confined Aquifer

    PubMed Central

    De Bartolo, Samuele; Fallico, Carmine; Veltri, Massimo

    2013-01-01

    Hydraulic conductivity and effective porosity values for the confined sandy loam aquifer of the Montalto Uffugo (Italy) test field were obtained by laboratory and field measurements; the first ones were carried out on undisturbed soil samples and the others by slug and aquifer tests. A direct simple-scaling analysis was performed for the whole range of measurement and a comparison among the different types of fractal models describing the scale behavior was made. Some indications about the largest pore size to utilize in the fractal models were given. The results obtained for a sandy loam soil show that it is possible to obtain global indications on the behavior of the hydraulic conductivity versus the porosity utilizing a simple scaling relation and a fractal model in coupled manner. PMID:24385876

  7. Phosphorus Concentrations in Stream-Water and Reference Samples - An Assessment of Laboratory Comparability

    USGS Publications Warehouse

    McHale, Michael R.; McChesney, Dennis

    2007-01-01

    In 2003, a study was conducted to evaluate the accuracy and precision of 10 laboratories that analyze water-quality samples for phosphorus concentrations in the Catskill Mountain region of New York State. Many environmental studies in this region rely on data from these different laboratories for water-quality analyses, and the data may be used in watershed modeling and management decisions. Therefore, it is important to determine whether the data reported by these laboratories are of comparable accuracy and precision. Each laboratory was sent 12 samples for triplicate analysis for total phosphorus, total dissolved phosphorus, and soluble reactive phosphorus. Eight of these laboratories reported results that met comparability criteria for all samples; the remaining two laboratories met comparability criteria for only about half of the analyses. Neither the analytical method used nor the sample concentration ranges appeared to affect the comparability of results. The laboratories whose results were comparable gave consistently comparable results throughout the concentration range analyzed, and the differences among methods did not diminish comparability. All laboratories had high data precision as indicated by sample triplicate results. In addition, the laboratories consistently reported total phosphorus values greater than total dissolved phosphorus values, and total dissolved phosphorus values greater than soluble reactive phosphorus values, as would be expected. The results of this study emphasize the importance of regular laboratory participation in sample-exchange programs.

  8. Potential for improved radiation thermometry measurement uncertainty through implementing a primary scale in an industrial laboratory

    NASA Astrophysics Data System (ADS)

    Willmott, Jon R.; Lowe, David; Broughton, Mick; White, Ben S.; Machin, Graham

    2016-09-01

    A primary temperature scale requires realising a unit in terms of its definition. For high temperature radiation thermometry in terms of the International Temperature Scale of 1990 this means extrapolating from the signal measured at the freezing temperature of gold, silver or copper using Planck’s radiation law. The difficulty in doing this means that primary scales above 1000 °C require specialist equipment and careful characterisation in order to achieve the extrapolation with sufficient accuracy. As such, maintenance of the scale at high temperatures is usually only practicable for National Metrology Institutes, and calibration laboratories have to rely on a scale calibrated against transfer standards. At lower temperatures it is practicable for an industrial calibration laboratory to have its own primary temperature scale, which reduces the number of steps between the primary scale and end user. Proposed changes to the SI that will introduce internationally accepted high temperature reference standards might make it practicable to have a primary high temperature scale in a calibration laboratory. In this study such a scale was established by calibrating radiation thermometers directly to high temperature reference standards. The possible reduction in uncertainty to an end user as a result of the reduced calibration chain was evaluated.

  9. [Assessment of biological sampling's quality in a medical laboratory: case of Côte d' Ivoire Institute Pasteur].

    PubMed

    Kouassi-M'Bengue, Alphonsine; Koffi, Stephane; Manizan, Pascale; Ouattara, Abdoulaye; N'Douba, Adele Kacou; Dosso, Mireille

    2008-01-01

    Assurance quality is important in medical laboratory, but in Africa, few laboratories are involved in this process. The aim of this study was to assess biological sampling's quality in a bacteriological laboratory. A cross sectional study was undertaken in medical bacteriological laboratory of Côte d' Ivoire Institute Pasteur during 6 months. All urines, saddles, and bronchial expectorations collected from ambulatory patients during this period were included in the study. The quality of urine's, saddles and bronchial expectorations' sampling for a bacteriological analysis was evaluated. An interview based on Guidelines of good laboratories practices and referential ISO 15189 was used. A total of 300 samples were indexed. On a total of 300 recorded biological samples, 224 (74.7%) were not in conformity. In 87.5% of the cases of nonconformities, an antibiotic's treatment were preliminary instituted before the sampling. Corrective actions were carried in the laboratory on 30 samples with 56.6% for the urines, 26.7% for the saddles and 16.7% for the bronchial expectorations. At the end of this study, it arises that the quality of the biological sampling received at the medical bacteriology laboratory need to be improved.

  10. On a path towards long-term sampling following the Deepwater Horizon: Initial insights

    NASA Astrophysics Data System (ADS)

    Reddy, C. M.

    2012-12-01

    During the past two decades in the United States, few areas contaminated from an oil spill have been revisited on the time scales from months to years. The lack of sampling is a missed opportunity to shine light on long-term processes, evaluate recovery, identify compounds most likely to persist, and apply new chemical and biological techniques. To address this issue, my laboratory has begun a land-based effort to collect oiled samples from the Gulf of Mexico beaches from the Deepwater Horizon disaster. Each sample is archived, analyzed, and available for others via an online repository. Detailed analysis of many of these samples has already been fruitful on determining the fate of the spilled oil, which will be discussed. This meeting is an ideal time to discuss strategies for long-term sampling and archiving. With support from the Gulf Research Initiative for the next nine years, the opportunities to use these samples will be frequent.

  11. Targeted surveillance for highly pathogenic avian influenza in migratory waterfowl across the conterminous United States: chapter 12

    USGS Publications Warehouse

    Farnsworth, Matthew L.; Kendall, William L.; Doherty, Paul F.; Miller, Ryan S.; White, Gary C.; Nichols, James D.; Burnham, Kenneth P.; Franklin, Alan B.; Majumdar, S.; Brenner, F.J.; Huffman, J.E.; McLean, R.G.; Panah, A.I.; Pietrobon, P.J.; Keeler, S.P.; Shive, S.

    2011-01-01

    Introduction of Asian strain H5N1 Highly Pathogenic avian influenca via waterfowl migration is one potential route of entry into the United States. In conjunction with state, tribe, and laboratory partners, the United States Department of Agriculture collected and tested 124,603 wild bird samples in 2006 as part of a national surveillance effort. A sampling plan was devised to increase the probability fo detecting Asian strain H5N1 at a national scale. Band recovery data were used to identify and prioritize sampling for wild migratory waterfowl, resulting in spatially targeted sampling recommendations focused on reads with high numbers of recoveries. We also compared the spatial and temporal distribution of the 2006 cloacal and fecal waterfowl sampling effort to the bird banding recovery data and found concordance between the two .Finally, we present improvements made to the 2007 fecal sampling component of the surveillance plan and suggest further improvements for future sampling.

  12. Laboratory Scale X-ray Fluorescence Tomography: Instrument Characterization and Application in Earth and Environmental Science.

    PubMed

    Laforce, Brecht; Vermeulen, Bram; Garrevoet, Jan; Vekemans, Bart; Van Hoorebeke, Luc; Janssen, Colin; Vincze, Laszlo

    2016-03-15

    A new laboratory scale X-ray fluorescence (XRF) imaging instrument, based on an X-ray microfocus tube equipped with a monocapillary optic, has been developed to perform XRF computed tomography experiments with both higher spatial resolution (20 μm) and a better energy resolution (130 eV @Mn-K(α)) than has been achieved up-to-now. This instrument opens a new range of possible applications for XRF-CT. Next to the analytical characterization of the setup by using well-defined model/reference samples, demonstrating its capabilities for tomographic imaging, the XRF-CT microprobe has been used to image the interior of an ecotoxicological model organism, Americamysis bahia. This had been exposed to elevated metal (Cu and Ni) concentrations. The technique allowed the visualization of the accumulation sites of copper, clearly indicating the affected organs, i.e. either the gastric system or the hepatopancreas. As another illustrative application, the scanner has been employed to investigate goethite spherules from the Cretaceous-Paleogene boundary, revealing the internal elemental distribution of these valuable distal ejecta layer particles.

  13. Cutting Silica Aerogel for Particle Extraction

    NASA Technical Reports Server (NTRS)

    Tsou, P.; Brownlee, D. E.; Glesias, R.; Grigoropoulos, C. P.; Weschler, M.

    2005-01-01

    The detailed laboratory analyses of extraterrestrial particles have revolutionized our knowledge of planetary bodies in the last three decades. This knowledge of chemical composition, morphology, mineralogy, and isotopics of particles cannot be provided by remote sensing. In order to acquire these detail information in the laboratories, the samples need be intact, unmelted. Such intact capture of hypervelocity particles has been developed in 1996. Subsequently silica aerogel was introduced as the preferred medium for intact capturing of hypervelocity particles and later showed it to be particularly suitable for the space environment. STARDUST, the 4th NASA Discovery mission to capture samples from 81P/Wild 2 and contemporary interstellar dust, is the culmination of these new technologies. In early laboratory experiments of launching hypervelocity projectiles into aerogel, there was the need to cut aerogel to isolate or extract captured particles/tracks. This is especially challenging for space captures, since there will be many particles/tracks of wide ranging scales closely located, even collocated. It is critical to isolate and extract one particle without compromising its neighbors since the full significance of a particle is not known until it is extracted and analyzed. To date, three basic techniques have been explored: mechanical cutting, lasers cutting and ion beam milling. We report the current findings.

  14. Field evaluation of the photo-induced electron transfer fluorogenic primers (PET) real-time PCR for the detection of Plasmodium falciparum in Tanzania

    PubMed Central

    2014-01-01

    Background Accurate diagnosis of malaria infections remains challenging, especially in the identification of submicroscopic infections. New molecular diagnostic tools that are inexpensive, sensitive enough to detect low-level infections and suitable in laboratory settings of resource-limited countries are required for malaria control and elimination programmes. Here the diagnostic potential of a recently developed photo-induced electron transfer fluorogenic primer (PET) real-time polymerase chain reaction (PCR) called PET-PCR was investigated. This study aimed to (i) evaluate the use of this assay as a method for the detection of both Plasmodium falciparum and other Plasmodium species infections in a developing country’s diagnostic laboratory; and, (ii) determine the assay’s sensitivity and specificity compared to a nested 18S rRNA PCR. Methods Samples used in this study were obtained from a previous study conducted in the region of Iringa, Tanzania. A total of 303 samples from eight health facilities in Tanzania were utilized for this evaluation. All samples were screened using the multiplex PET-PCR assay designed to detect Plasmodium genus and P. falciparum initially in laboratory in Tanzania and then repeated at a reference laboratory at the CDC in the USA. Microscopy data was available for all the 303 samples. A subset of the samples were tested in a blinded fashion to find the sensitivity and specificity of the PET-PCR compared to the nested 18S rRNA PCR. Results Compared to microscopy, the PET-PCR assay was 59% more sensitive in detecting P. falciparum infections. The observed sensitivity and specificity were 100% (95% confidence interval (CI0.95) = 94-100%) and (CI0.95 = 96-100%), respectively, for the PET-PCR assay when compared to nested 18S rRNA PCR. When compared to 18S rRNA PCR, microscopy had a low sensitivity of 40% (CI0.95 = 23-61%) and specificity of 100% (CI0.95 = 96-100%). The PET-PCR results performed in the field laboratory in Tanzania were in 100% concordance with the results obtained at the reference laboratory in the USA. Conclusion The PET-PCR is a new molecular diagnostic tool with similar performance characteristics as commonly used PCR methods that is less expensive, easy to use, and amiable to large scale-surveillance studies in developing country settings. PMID:24467985

  15. PBX 9502 Gas Generation Progress Report FY17

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holmes, Matthew David; Erickson, Michael Andrew Englert

    The self-ignition (“cookoff”) behavior of PBX 9502 depends on the dynamic evolution of gas permeability and physical damage in the material. The time-resolved measurement of product gas generation yields insight regarding the crucial properties that dominate cookoff behavior. We report on small-scale laboratory testing performed in FY17, in which small unconfined samples of PBX 9502 were heated in a small custom-built sealed pressure vessel to self-ignition. We recorded time-lapse video of the evolving physical changes in the sample, quasi-static long-duration pressure rise, then high-speed video and dynamic pressure rise of the cookoff event. We report the full pressure attained duringmore » the cookoff of a 1.02g sample in a free volume of 62.5 cm 3.« less

  16. Crystallization and dissolution of airborne sea-salts on weathered marble in a coastal environment at Delos (Cyclades-Greece)

    NASA Astrophysics Data System (ADS)

    Chabas, A.; Jeannette, D.; Lefèvre, R. A.

    Far from the ground moisture zone, marble remains of Delos archaeological site have undergone an extensive weathering through contour scaling and granular disintegration. Comparison of the analytical results from analytical scanning electron microscopy examination of surface samples of weathered marble and air filtration membranes confirms the atmospheric transport of marine salts and their deposition on stone surface. A laboratory experiment emphasizes the role of these atmospheric salts in the weathering process of marbles in coastal environment.

  17. Refining of Military Jet Fuels from Shale Oil. Volume I. Part II. Preparation of Laboratory-Scale Fuel Samples.

    DTIC Science & Technology

    1982-03-01

    ON SPEC Meeting Specifications *1 OXY Test Series on In Situ Shale Oil P Pressure (P + N) Paraffins and Naphthenes PHO Test Series on Above-Ground...material, the crude shale is heated and processed through caustic desalt- ing similar to conventional technology. The desalted oil is mixed with recycle...with hot regenerated catalyst. Spent catalyst and oil vapors are disengaqed by -.eans of high temperature cyclones. The spent catalyst first passes

  18. The Physcomitrella patens gene atlas project: large-scale RNA-seq based expression data.

    PubMed

    Perroud, Pierre-François; Haas, Fabian B; Hiss, Manuel; Ullrich, Kristian K; Alboresi, Alessandro; Amirebrahimi, Mojgan; Barry, Kerrie; Bassi, Roberto; Bonhomme, Sandrine; Chen, Haodong; Coates, Juliet C; Fujita, Tomomichi; Guyon-Debast, Anouchka; Lang, Daniel; Lin, Junyan; Lipzen, Anna; Nogué, Fabien; Oliver, Melvin J; Ponce de León, Inés; Quatrano, Ralph S; Rameau, Catherine; Reiss, Bernd; Reski, Ralf; Ricca, Mariana; Saidi, Younousse; Sun, Ning; Szövényi, Péter; Sreedasyam, Avinash; Grimwood, Jane; Stacey, Gary; Schmutz, Jeremy; Rensing, Stefan A

    2018-07-01

    High-throughput RNA sequencing (RNA-seq) has recently become the method of choice to define and analyze transcriptomes. For the model moss Physcomitrella patens, although this method has been used to help analyze specific perturbations, no overall reference dataset has yet been established. In the framework of the Gene Atlas project, the Joint Genome Institute selected P. patens as a flagship genome, opening the way to generate the first comprehensive transcriptome dataset for this moss. The first round of sequencing described here is composed of 99 independent libraries spanning 34 different developmental stages and conditions. Upon dataset quality control and processing through read mapping, 28 509 of the 34 361 v3.3 gene models (83%) were detected to be expressed across the samples. Differentially expressed genes (DEGs) were calculated across the dataset to permit perturbation comparisons between conditions. The analysis of the three most distinct and abundant P. patens growth stages - protonema, gametophore and sporophyte - allowed us to define both general transcriptional patterns and stage-specific transcripts. As an example of variation of physico-chemical growth conditions, we detail here the impact of ammonium supplementation under standard growth conditions on the protonemal transcriptome. Finally, the cooperative nature of this project allowed us to analyze inter-laboratory variation, as 13 different laboratories around the world provided samples. We compare differences in the replication of experiments in a single laboratory and between different laboratories. © 2018 The Authors The Plant Journal © 2018 John Wiley & Sons Ltd.

  19. Biodegradation modelling of a dissolved gasoline plume applying independent laboratory and field parameters

    NASA Astrophysics Data System (ADS)

    Schirmer, Mario; Molson, John W.; Frind, Emil O.; Barker, James F.

    2000-12-01

    Biodegradation of organic contaminants in groundwater is a microscale process which is often observed on scales of 100s of metres or larger. Unfortunately, there are no known equivalent parameters for characterizing the biodegradation process at the macroscale as there are, for example, in the case of hydrodynamic dispersion. Zero- and first-order degradation rates estimated at the laboratory scale by model fitting generally overpredict the rate of biodegradation when applied to the field scale because limited electron acceptor availability and microbial growth are not considered. On the other hand, field-estimated zero- and first-order rates are often not suitable for predicting plume development because they may oversimplify or neglect several key field scale processes, phenomena and characteristics. This study uses the numerical model BIO3D to link the laboratory and field scales by applying laboratory-derived Monod kinetic degradation parameters to simulate a dissolved gasoline field experiment at the Canadian Forces Base (CFB) Borden. All input parameters were derived from independent laboratory and field measurements or taken from the literature a priori to the simulations. The simulated results match the experimental results reasonably well without model calibration. A sensitivity analysis on the most uncertain input parameters showed only a minor influence on the simulation results. Furthermore, it is shown that the flow field, the amount of electron acceptor (oxygen) available, and the Monod kinetic parameters have a significant influence on the simulated results. It is concluded that laboratory-derived Monod kinetic parameters can adequately describe field scale degradation, provided all controlling factors are incorporated in the field scale model. These factors include advective-dispersive transport of multiple contaminants and electron acceptors and large-scale spatial heterogeneities.

  20. Preparations for ExoMars: Learning Lessons from Curiosity

    NASA Astrophysics Data System (ADS)

    Edwards, Peter Henry; Hutchinson, Ian; Morgan, Sally; McHugh, Melissa; Malherbe, Cedric; Lerman, Hannah; INGLEY, Richard

    2016-10-01

    In 2020, the European Space Agency will launch its first Mars rover mission, ExoMars. The rover will use a drill to obtain samples from up to 2m below the Martian surface that will then be analysed using a variety of analytical instruments, including the Raman Laser Spectrometer (RLS), which will be the first Raman spectrometer to be used on a planetary mission.To prepare for ExoMars RLS operations, we report on a series of experiments that have been performed in order to investigate the response of a representative Raman instrument to a number of analogue samples (selected based on the types of material known to be important, following investigations performed by NASA's Mars Science Laboratory, MSL, on the Curiosity rover). Raman spectroscopy will provide molecular and mineralogical information about the samples obtained from the drill cores on ExoMars. MSL acquires similar information using the CheMin XRD instrument which analyses samples acquired from drill holes several centimetres deep. Like Raman spectroscopy, XRD also provides information on the mineralogical makeup of the analysed samples.The samples in our study were selected based on CheMin data obtained from drill sites at Yellowknife Bay, one of the first locations visited by Curiosity (supplemented with additional fine scale elemental information obtained with the ChemCam LIBS laser instrument). Once selected (or produced), the samples were characterised using standard laboratory XRD and XRF instruments (in order to compare with the data obtained by CheMin) and a standard, laboratory based LIBS system (in order to compare with the ChemCam data). This characterisation provides confirmation that the analogue samples are representative of the materials likely to be encountered on Mars by the ExoMars rover.A representative, miniaturised Raman spectrometer was used to analyse the samples, using acquisition strategies and operating modes similar to those expected for the ExoMars instrument. The type of minerals detected are identified and compared to the information typically acquired using other analytical science techniques investigating in order to highlight the benefits and drawbacks of using Raman spectroscopy for planetary science applications.

  1. Impact of capturing rainfall scavenging intermittency using cloud superparameterization on simulated continental scale wildfire smoke transport

    NASA Astrophysics Data System (ADS)

    Pritchard, M. S.; Kooperman, G. J.; Zhao, Z.; Wang, M.; Russell, L. M.; Somerville, R. C.; Ghan, S. J.

    2011-12-01

    Evaluating the fidelity of new aerosol physics in climate models is confounded by uncertainties in source emissions, systematic error in cloud parameterizations, and inadequate sampling of long-range plume concentrations. To explore the degree to which cloud parameterizations distort aerosol processing and scavenging, the Pacific Northwest National Laboratory (PNNL) Aerosol-Enabled Multi-Scale Modeling Framework (AE-MMF), a superparameterized branch of the Community Atmosphere Model Version 5 (CAM5), is applied to represent the unusually active and well sampled North American wildfire season in 2004. In the AE-MMF approach, the evolution of double moment aerosols in the exterior global resolved scale is linked explicitly to convective statistics harvested from an interior cloud resolving scale. The model is configured in retroactive nudged mode to observationally constrain synoptic meteorology, and Arctic wildfire activity is prescribed at high space/time resolution using data from the Global Fire Emissions Database. Comparisons against standard CAM5 bracket the effect of superparameterization to isolate the role of capturing rainfall intermittency on the bulk characteristics of 2004 Arctic plume transport. Ground based lidar and in situ aircraft wildfire plume constraints from the International Consortium for Atmospheric Research on Transport and Transformation field campaign are used as a baseline for model evaluation.

  2. Characterization of gaseous emissions and ashes from the combustion of furniture waste.

    PubMed

    Moreno, Ana Isabel; Font, Rafael; Conesa, Juan A

    2016-12-01

    Gaseous emissions and ash obtained in the combustion of furniture waste have been studied, with particular emphasis on the emissions of hazardous pollutants, such as PCDD/Fs and dl-PCBS. Two different combustion procedures were carried out, one of them in a conventional residential stove (without an automatic control of combustion air and bad mixing of combustion gases with air), and the other in a laboratory-scale reactor (operating under substoichiometric conditions). Three different experiments were carried out in the residential stove, in which the gaseous emissions and ashes obtained were analysed. The fuel burnt out in two of the experiments was furniture wood waste and in one of the experiments, the fuel burnt out was briquettes composed of a mixture of furniture wood with 10wt.% of polyurethane foam. One of the purposes of these experiments was the evaluation of the possible inhibition effect of the higher nitrogen content on the formation of PCDD/Fs. Slight inhibition of the PCDD/F formation was found although, it is noteworthy that the lowest yield of PAHs, volatile and semi-volatile compounds were obtained in the combustion of these briquettes. In all experiments, the emission factors of polychlorinated dibenzo-p-dioxins and dibenzofurans and dioxin-like polychlorinated biphenyls (PCDD/Fs and dl-PCBs) were between 29 and 74ng WHO-TEQ/kg sample burnt, lower than that obtained by other authors in the burning of pine needles and cones. PCDD/Fs and dl-PCBs emissions from furniture wood waste combustion were also analysed in the laboratory scale reactor at 850°C and the results were compared with the values obtained from the combustion of solid wood (untreated wood). The total equivalent toxicity obtained was 21.1ng WHO-TEQ/kg sample for combustion of furniture wood waste, which is low in comparison with those obtained for other waste combustion in similar conditions. In the laboratory scale reactor, PCDFs were the dominant compounds in the profiles of PCDD/Fs, by contrast, in the combustion in the residential stove, the majority compounds were PCDDs, due to the different operation conditions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Multi-Scale Transport Properties of Fine-Grained Rocks: A Case Study of the Kirtland Formation, San Juan Basin, USA

    NASA Astrophysics Data System (ADS)

    Heath, J. E.; Dewers, T. A.; McPherson, B. J.; Wilson, T. H.; Flach, T.

    2009-12-01

    Understanding and characterizing transport properties of fine-grained rocks is critical in development of shale gas plays or assessing retention of CO2 at geologic storage sites. Difficulties arise in that both small scale (i.e., ~ nm) properties of the rock matrix and much larger scale fractures, faults, and sedimentological architecture govern migration of multiphase fluids. We present a multi-scale investigation of sealing and transport properties of the Kirtland Formation, which is a regional aquitard and reservoir seal in the San Juan Basin, USA. Sub-micron dual FIB/SEM imaging and reconstruction of 3D pore networks in core samples reveal a variety of pore types, including slit-shaped pores that are co-located with sedimentary structures and variations in mineralogy. Micron-scale chemical analysis and XRD reveal a mixture of mixed-layer smectite/illite, chlorite, quartz, and feldspar with little organic matter. Analysis of sub-micron digital reconstructions, mercury capillary injection pressure, and gas breakthrough measurements indicate a high quality sealing matrix. Natural full and partially mineralized fractures observed in core and in FMI logs include those formed from early soil-forming processes, differential compaction, and tectonic events. The potential impact of both fracture and matrix properties on large-scale transport is investigated through an analysis of natural helium from core samples, 3D seismic data and poro-elastic modeling. While seismic interpretations suggest considerable fracturing of the Kirtland, large continuous fracture zones and faults extending through the seal to the surface cannot be inferred from the data. Observed Kirtland Formation multi-scale transport properties are included as part of a risk assessment methodology for CO2 storage. Acknowledgements: The authors gratefully acknowledge the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory for sponsoring this project. The DOE’s Basic Energy Science Office funded the dual FIB/SEM analysis. The Kirtland Formation overlies the coal seams of the Fruitland into which CO2 has been injected as a Phase II demonstration of the Southwest Regional Partnership on Carbon Sequestration. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the U.S. Department of Energy under contract DE-ACOC4-94AL85000.

  4. Quantifying Diapycnal Mixing in an Energetic Ocean

    NASA Astrophysics Data System (ADS)

    Ivey, Gregory N.; Bluteau, Cynthia E.; Jones, Nicole L.

    2018-01-01

    Turbulent diapycnal mixing controls global circulation and the distribution of tracers in the ocean. For turbulence in stratified shear flows, we introduce a new turbulent length scale Lρ dependent on χ. We show the flux Richardson number Rif is determined by the dimensionless ratio of three length scales: the Ozmidov scale LO, the Corrsin shear scale LS, and Lρ. This new model predicts that Rif varies from 0 to 0.5, which we test primarily against energetic field observations collected in 100 m of water on the Australian North West Shelf (NWS), in addition to laboratory observations. The field observations consisted of turbulence microstructure vertical profiles taken near moored temperature and velocity turbulence time series. Irrespective of the value of the gradient Richardson number Ri, both instruments yielded a median Rif=0.17, while the observed Rif ranged from 0.01 to 0.50, in agreement with the predicted range of Rif. Using a Prandtl mixing length model, we show that diapycnal mixing Kρ can be predicted from Lρ and the background vertical shear S. Using field and laboratory observations, we show that Lρ=0.3LE where LE is the Ellison length scale. The diapycnal diffusivity can thus be calculated from Kρ=0.09LES2. This prediction agrees very well with the diapycnal mixing estimates obtained from our moored turbulence instruments for observed diffusivities as large as 10-1 m2s-1. Moorings with relatively low sampling rates can thus provide long time series estimates of diapycnal mixing rates, significantly increasing the number of diapycnal mixing estimates in the ocean.

  5. Does an inter-flaw length control the accuracy of rupture forecasting in geological materials?

    NASA Astrophysics Data System (ADS)

    Vasseur, Jérémie; Wadsworth, Fabian B.; Heap, Michael J.; Main, Ian G.; Lavallée, Yan; Dingwell, Donald B.

    2017-10-01

    Multi-scale failure of porous materials is an important phenomenon in nature and in material physics - from controlled laboratory tests to rockbursts, landslides, volcanic eruptions and earthquakes. A key unsolved research question is how to accurately forecast the time of system-sized catastrophic failure, based on observations of precursory events such as acoustic emissions (AE) in laboratory samples, or, on a larger scale, small earthquakes. Until now, the length scale associated with precursory events has not been well quantified, resulting in forecasting tools that are often unreliable. Here we test the hypothesis that the accuracy of the forecast failure time depends on the inter-flaw distance in the starting material. We use new experimental datasets for the deformation of porous materials to infer the critical crack length at failure from a static damage mechanics model. The style of acceleration of AE rate prior to failure, and the accuracy of forecast failure time, both depend on whether the cracks can span the inter-flaw length or not. A smooth inverse power-law acceleration of AE rate to failure, and an accurate forecast, occurs when the cracks are sufficiently long to bridge pore spaces. When this is not the case, the predicted failure time is much less accurate and failure is preceded by an exponential AE rate trend. Finally, we provide a quantitative and pragmatic correction for the systematic error in the forecast failure time, valid for structurally isotropic porous materials, which could be tested against larger-scale natural failure events, with suitable scaling for the relevant inter-flaw distances.

  6. High resolution wind turbine wake measurements with a scanning lidar

    NASA Astrophysics Data System (ADS)

    Herges, T. G.; Maniaci, D. C.; Naughton, B. T.; Mikkelsen, T.; Sjöholm, M.

    2017-05-01

    High-resolution lidar wake measurements are part of an ongoing field campaign being conducted at the Scaled Wind Farm Technology facility by Sandia National Laboratories and the National Renewable Energy Laboratory using a customized scanning lidar from the Technical University of Denmark. One of the primary objectives is to collect experimental data to improve the predictive capability of wind plant computational models to represent the response of the turbine wake to varying inflow conditions and turbine operating states. The present work summarizes the experimental setup and illustrates several wake measurement example cases. The cases focus on demonstrating the impact of the atmospheric conditions on the wake shape and position, and exhibit a sample of the data that has been made public through the Department of Energy Atmosphere to Electrons Data Archive and Portal.

  7. Experimental demonstration of cheap and accurate phase estimation

    NASA Astrophysics Data System (ADS)

    Rudinger, Kenneth; Kimmel, Shelby; Lobser, Daniel; Maunz, Peter

    We demonstrate experimental implementation of robust phase estimation (RPE) to learn the phases of X and Y rotations on a trapped Yb+ ion qubit.. Unlike many other phase estimation protocols, RPE does not require ancillae nor near-perfect state preparation and measurement operations. Additionally, its computational requirements are minimal. Via RPE, using only 352 experimental samples per phase, we estimate phases of implemented gates with errors as small as 10-4 radians, as validated using gate set tomography. We also demonstrate that these estimates exhibit Heisenberg scaling in accuracy. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  8. The economic impact of poor sample quality in clinical chemistry laboratories: results from a global survey.

    PubMed

    Erdal, Erik P; Mitra, Debanjali; Khangulov, Victor S; Church, Stephen; Plokhoy, Elizabeth

    2017-03-01

    Background Despite advances in clinical chemistry testing, poor blood sample quality continues to impact laboratory operations and the quality of results. While previous studies have identified the preanalytical causes of lower sample quality, few studies have examined the economic impact of poor sample quality on the laboratory. Specifically, the costs associated with workarounds related to fibrin and gel contaminants remain largely unexplored. Methods A quantitative survey of clinical chemistry laboratory stakeholders across 10 international regions, including countries in North America, Europe and Oceania, was conducted to examine current blood sample testing practices, sample quality issues and practices to remediate poor sample quality. Survey data were used to estimate costs incurred by laboratories to mitigate sample quality issues. Results Responses from 164 participants were included in the analysis, which was focused on three specific issues: fibrin strands, fibrin masses and gel globules. Fibrin strands were the most commonly reported issue, with an overall incidence rate of ∼3%. Further, 65% of respondents indicated that these issues contribute to analyzer probe clogging, and the majority of laboratories had visual inspection and manual remediation practices in place to address fibrin- and gel-related quality problems (55% and 70%, respectively). Probe maintenance/replacement, visual inspection and manual remediation were estimated to carry significant costs for the laboratories surveyed. Annual cost associated with lower sample quality and remediation related to fibrin and/or gel globules for an average US laboratory was estimated to be $100,247. Conclusions Measures to improve blood sample quality present an important step towards improved laboratory operations.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schwantes, Jon M.

    Kelly Fitzgerald Kelly Fitzgerald assisted with laboratory testing for an ongoing R&D project known as Electrochemically Modulated Separation (EMS) for on-line rapid preseparations of actinides prior to mass spectrometry analysis. Ryne Burgess Ryne Burgess used SCALE 5.1 ORIGEN-ARP to predict isotope libraries for the Units 1, 2 and 3 reactors and Unit 4 spent fuel pool for comparing against measurements of environmental sampled collected at the site in order to identify the source terms of the accident. Comparison of the cesium 134/137 and cesium 136/137 ratios observed in environmental samples and ORIGEN-ARP predictions indicated that the Unit 4 Spent Fuelmore » Pool did not significantly contribute to radionuclide release during the Fukushima Daiichi accident.« less

  10. The Sulcis Storage Project: Status of the First Italian Initiative for Pilot-Scale Geological Sequestration of CO2

    NASA Astrophysics Data System (ADS)

    Plaisant, A.; Maggio, E.; Pettinau, A.

    2016-12-01

    The deep aquifer located at a depth of about 1000-1500 m within fractured carbonate in the Sulcis coal basin (South-West Sardinia, Italy) constitutes a potential reservoir to develop a pilot-scale CO2 storage site. The occurrence of several coal mines and the geology of the basin also provide favourable condition to install a permanent infrastructures where advanced CO2 storage technologies can be developed. Overall, the Sulcis project will allow to characterize the Sulcis coal basin (South West Sardinia, Italy) and to develop a permanent infrastructure (know-how, equipment, laboratories, etc.) for advanced international studies on CO2 storage. The research activities are structured in two different phases: (i) site characterization, including the construction of an underground and a fault laboratories and (ii) the installation of a test site for small-scale injection of CO2. In particular, the underground laboratory will host geochemical and geophysical experiments on rocks, taking advantages of the buried environment and the very well confined conditions in the galleries; in parallel, the fault laboratory will be constructed to study CO2 leakage phenomena in a selected fault. The project is currently ongoing and some preliminary results will be presented in this work as well as the structure of the project as a whole. More in detail, preliminary activities comprise: (i) geochemical monitoring; (ii) the minero-petrographycal, physical and geophysical characterization of the rock samples; (iii) the development of both static and dynamic geological models of the reservoir; (iv) the structural geology and fault analysis; (v) the assessment of natural seismicity through a monitoring network (vi) the re-processing and the analysis of the reflection seismic data. Future activities will comprise: (i) the drilling of shallow exploration wells near the faults; (ii) the construction of both the above mentioned laboratories; (iii) drilling of a deep exploration well (1,500 m); (iv) injection tests. Preliminary analyses show that the rocks of the carbonate formation present a low porosity, but the formation is characterized by a good permeability for fractures and karst. The faults are typically sealed and petrophysical properties of caprock and reservoir are spatially heterogeneous.

  11. Pretreatment Engineering Platform Phase 1 Final Test Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurath, Dean E.; Hanson, Brady D.; Minette, Michael J.

    2009-12-23

    Pacific Northwest National Laboratory (PNNL) was tasked by Bechtel National Inc. (BNI) on the River Protection Project, Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to conduct testing to demonstrate the performance of the WTP Pretreatment Facility (PTF) leaching and ultrafiltration processes at an engineering-scale. In addition to the demonstration, the testing was to address specific technical issues identified in Issue Response Plan for Implementation of External Flowsheet Review Team (EFRT) Recommendations - M12, Undemonstrated Leaching Processes.( ) Testing was conducted in a 1/4.5-scale mock-up of the PTF ultrafiltration system, the Pretreatment Engineering Platform (PEP). Parallel laboratory testing wasmore » conducted in various PNNL laboratories to allow direct comparison of process performance at an engineering-scale and a laboratory-scale. This report presents and discusses the results of those tests.« less

  12. USGS Blind Sample Project: monitoring and evaluating laboratory analytical quality

    USGS Publications Warehouse

    Ludtke, Amy S.; Woodworth, Mark T.

    1997-01-01

    The U.S. Geological Survey (USGS) collects and disseminates information about the Nation's water resources. Surface- and ground-water samples are collected and sent to USGS laboratories for chemical analyses. The laboratories identify and quantify the constituents in the water samples. Random and systematic errors occur during sample handling, chemical analysis, and data processing. Although all errors cannot be eliminated from measurements, the magnitude of their uncertainty can be estimated and tracked over time. Since 1981, the USGS has operated an independent, external, quality-assurance project called the Blind Sample Project (BSP). The purpose of the BSP is to monitor and evaluate the quality of laboratory analytical results through the use of double-blind quality-control (QC) samples. The information provided by the BSP assists the laboratories in detecting and correcting problems in the analytical procedures. The information also can aid laboratory users in estimating the extent that laboratory errors contribute to the overall errors in their environmental data.

  13. External quality assessment study for ebolavirus PCR-diagnostic promotes international preparedness during the 2014 – 2016 Ebola outbreak in West Africa

    PubMed Central

    Jacobsen, Sonja; Patel, Pranav; Rieger, Toni; Eickmann, Markus; Becker, Stephan; Günther, Stephan; Naidoo, Dhamari; Schrick, Livia; Keeren, Kathrin; Targosz, Angelina; Teichmann, Anette; Formenty, Pierre; Niedrig, Matthias

    2017-01-01

    During the recent Ebola outbreak in West Africa several international mobile laboratories were deployed to the mainly affected countries Guinea, Sierra Leone and Liberia to provide ebolavirus diagnostic capacity. Additionally, imported cases and small outbreaks in other countries required global preparedness for Ebola diagnostics. Detection of viral RNA by reverse transcription polymerase chain reaction has proven effective for diagnosis of ebolavirus disease and several assays are available. However, reliability of these assays is largely unknown and requires serious evaluation. Therefore, a proficiency test panel of 11 samples was generated and distributed on a global scale. Panels were analyzed by 83 expert laboratories and 106 data sets were returned. From these 78 results were rated optimal and 3 acceptable, 25 indicated need for improvement. While performance of the laboratories deployed to West Africa was superior to the overall performance there was no significant difference between the different assays applied. PMID:28459810

  14. External quality assessment study for ebolavirus PCR-diagnostic promotes international preparedness during the 2014 - 2016 Ebola outbreak in West Africa.

    PubMed

    Ellerbrok, Heinz; Jacobsen, Sonja; Patel, Pranav; Rieger, Toni; Eickmann, Markus; Becker, Stephan; Günther, Stephan; Naidoo, Dhamari; Schrick, Livia; Keeren, Kathrin; Targosz, Angelina; Teichmann, Anette; Formenty, Pierre; Niedrig, Matthias

    2017-05-01

    During the recent Ebola outbreak in West Africa several international mobile laboratories were deployed to the mainly affected countries Guinea, Sierra Leone and Liberia to provide ebolavirus diagnostic capacity. Additionally, imported cases and small outbreaks in other countries required global preparedness for Ebola diagnostics. Detection of viral RNA by reverse transcription polymerase chain reaction has proven effective for diagnosis of ebolavirus disease and several assays are available. However, reliability of these assays is largely unknown and requires serious evaluation. Therefore, a proficiency test panel of 11 samples was generated and distributed on a global scale. Panels were analyzed by 83 expert laboratories and 106 data sets were returned. From these 78 results were rated optimal and 3 acceptable, 25 indicated need for improvement. While performance of the laboratories deployed to West Africa was superior to the overall performance there was no significant difference between the different assays applied.

  15. The Infant Version of the Laboratory Temperament Assessment Battery (Lab-TAB): Measurement Properties and Implications for Concepts of Temperament

    PubMed Central

    Planalp, Elizabeth M.; Van Hulle, Carol; Gagne, Jeffrey R.; Goldsmith, H. Hill

    2017-01-01

    We describe large-sample research using the Infant Laboratory Temperament Assessment Battery (Lab-TAB; Goldsmith and Rothbart, 1996) in 1,076 infants at 6 and 12 months of age. The Lab-TAB was designed to assess temperament dimensions through a series of episodes that mimic everyday situations. Our goal is to provide guidelines for scoring Lab-TAB episodes to derive temperament composites. We also present a set of analyses examining mean differences and stability of temperament in early infancy, gender differences in infant temperament, as well as a validation of Lab-TAB episodes and composites with parent reported Infant Behavior Questionnaire (IBQ; Rothbart, 1981) scales. In general, laboratory observed temperament was only modestly related to parent reported temperament. However, temperament measures were significantly stable across time and several gender differences that align with previous research emerged. In sum, the Lab-TAB usefully assesses individual differences in infant emotionality. PMID:28596748

  16. Self-assembling iron oxyhydroxide/oxide tubular structures: laboratory-grown and field examples from Rio Tinto.

    PubMed

    Barge, Laura M; Cardoso, Silvana S S; Cartwright, Julyan H E; Doloboff, Ivria J; Flores, Erika; Macías-Sánchez, Elena; Sainz-Díaz, C Ignacio; Sobrón, Pablo

    2016-11-01

    Rio Tinto in southern Spain has become of increasing astrobiological significance, in particular for its similarity to environments on early Mars. We present evidence of tubular structures from sampled terraces in the stream bed at the source of the river, as well as ancient, now dry, terraces. This is the first reported finding of tubular structures in this particular environment. We propose that some of these structures could be formed through self-assembly via an abiotic mechanism involving templated precipitation around a fluid jet, a similar mechanism to that commonly found in so-called chemical gardens. Laboratory experiments simulating the formation of self-assembling iron oxyhydroxide tubes via chemical garden/chemobrionic processes form similar structures. Fluid-mechanical scaling analysis demonstrates that the proposed mechanism is plausible. Although the formation of tube structures is not itself a biosignature, the iron mineral oxidation gradients across the tube walls in laboratory and field examples may yield information about energy gradients and potentially habitable environments.

  17. Self-assembling iron oxyhydroxide/oxide tubular structures: laboratory-grown and field examples from Rio Tinto

    PubMed Central

    Barge, Laura M.; Doloboff, Ivria J.; Flores, Erika; Sobrón, Pablo

    2016-01-01

    Rio Tinto in southern Spain has become of increasing astrobiological significance, in particular for its similarity to environments on early Mars. We present evidence of tubular structures from sampled terraces in the stream bed at the source of the river, as well as ancient, now dry, terraces. This is the first reported finding of tubular structures in this particular environment. We propose that some of these structures could be formed through self-assembly via an abiotic mechanism involving templated precipitation around a fluid jet, a similar mechanism to that commonly found in so-called chemical gardens. Laboratory experiments simulating the formation of self-assembling iron oxyhydroxide tubes via chemical garden/chemobrionic processes form similar structures. Fluid-mechanical scaling analysis demonstrates that the proposed mechanism is plausible. Although the formation of tube structures is not itself a biosignature, the iron mineral oxidation gradients across the tube walls in laboratory and field examples may yield information about energy gradients and potentially habitable environments. PMID:27956875

  18. 3D modeling of carbonates petro-acoustic heterogeneities

    NASA Astrophysics Data System (ADS)

    Baden, Dawin; Guglielmi, Yves; Saracco, Ginette; Marié, Lionel; Viseur, Sophie

    2015-04-01

    Characterizing carbonate reservoirs heterogeneity is a challenging issue for Oil & Gas Industry, CO2 sequestration and all kinds of fluid manipulations in natural reservoirs, due to the significant impact of heterogeneities on fluid flow and storage within the reservoir. Although large scale (> meter) heterogeneities such as layers petrophysical contrasts are well addressed by computing facies-based models, low scale (< meter) heterogeneities are often poorly constrained because of the complexity in predicting their spatial arrangement. In this study, we conducted petro-acoustic measurements on cores of different size and diameter (Ø = 1", 1.5" and 5") in order to evaluate anisotropy or heterogeneity in carbonates at different laboratory scales. Different types of heterogeneities which generally occur in carbonate reservoir units (e.g. petrographic, diagenetic, and tectonic related) were sampled. Dry / wet samples were investigated with different ultrasonic apparatus and using different sensors allowing acoustic characterization through a bandwidth varying from 50 to 500 kHz. Comprehensive measurements realized on each samples allowed statistical analyses of petro-acoustic properties such as attenuation, shear and longitudinal wave velocity. The cores properties (geological and acoustic facies) were modeled in 3D using photogrammetry and GOCAD geo-modeler. This method successfully allowed detecting and imaging in three dimensions differential diagenesis effects characterized by the occurrence of decimeter-scale diagenetic horizons in samples assumed to be homogeneous and/or different diagenetic sequences between shells filling and the packing matrix. We then discuss how small interfaces such as cracks, stylolithes and laminations which are also imaged may have guided these differential effects, considering that understanding the processes may be taken as an analogue to actual fluid drainage complexity in deep carbonate reservoir.

  19. Virtual Patterson Experiment - A Way to Access the Rheology of Aggregates and Melanges

    NASA Astrophysics Data System (ADS)

    Delannoy, Thomas; Burov, Evgueni; Wolf, Sylvie

    2014-05-01

    Understanding the mechanisms of lithospheric deformation requires bridging the gap between human-scale laboratory experiments and the huge geological objects they represent. Those experiments are limited in spatial and time scale as well as in choice of materials (e.g., mono-phase minerals, exaggerated temperatures and strain rates), which means that the resulting constitutive laws may not fully represent real rocks at geological spatial and temporal scales. We use the thermo-mechanical numerical modelling approach as a tool to link both experiments and nature and hence better understand the rheology of the lithosphere, by enabling us to study the behavior of polymineralic aggregates and their impact on the localization of the deformation. We have adapted the large strain visco-elasto-plastic Flamar code to allow it to operate at all spatial and temporal scales, from sub-grain to geodynamic scale, and from seismic time scales to millions of years. Our first goal was to reproduce real rock mechanics experiments on deformation of mono and polymineralic aggregates in Patterson's load machine in order to deepen our understanding of the rheology of polymineralic rocks. In particular, we studied in detail the deformation of a 15x15 mm mica-quartz sample at 750 °C and 300 MPa. This mixture includes a molten phase and a solid phase in which shear bands develop as a result of interactions between ductile and brittle deformation and stress concentration at the boundaries between weak and strong phases. We used digitized x-ray scans of real samples as initial configuration for the numerical models so the model-predicted deformation and stress-strain behavior can match those observed in the laboratory experiment. Analyzing the numerical experiments providing the best match with the press experiments and making other complementary models by changing different parameters in the initial state (strength contrast between the phases, proportions, microstructure, etc.) provides a number of new elements of understanding of the mechanisms governing the localization of the deformation across the aggregates. We next used stress-strain curves derived from the numerical experiments to study in detail the evolution of the rheological behavior of each mineral phase as well as that of the mixtures in order to formulate constitutive relations for mélanges and polymineralic aggregates. The next step of our approach would be to link the constitutive laws obtained at small scale (laws that govern the rheology of a polymineralic aggregate, the effect of the presence of a molten phase, etc.) to the large-scale behavior of the Earth by implementing them in lithosphere-scale models.

  20. Do you kiss your mother with that mouth? An authentic large-scale undergraduate research experience in mapping the human oral microbiome.

    PubMed

    Wang, Jack T H; Daly, Joshua N; Willner, Dana L; Patil, Jayee; Hall, Roy A; Schembri, Mark A; Tyson, Gene W; Hugenholtz, Philip

    2015-05-01

    Clinical microbiology testing is crucial for the diagnosis and treatment of community and hospital-acquired infections. Laboratory scientists need to utilize technical and problem-solving skills to select from a wide array of microbial identification techniques. The inquiry-driven laboratory training required to prepare microbiology graduates for this professional environment can be difficult to replicate within undergraduate curricula, especially in courses that accommodate large student cohorts. We aimed to improve undergraduate scientific training by engaging hundreds of introductory microbiology students in an Authentic Large-Scale Undergraduate Research Experience (ALURE). The ALURE aimed to characterize the microorganisms that reside in the healthy human oral cavity-the oral microbiome-by analyzing hundreds of samples obtained from student volunteers within the course. Students were able to choose from selective and differential culture media, Gram-staining, microscopy, as well as polymerase chain reaction (PCR) and 16S rRNA gene sequencing techniques, in order to collect, analyze, and interpret novel data to determine the collective oral microbiome of the student cohort. Pre- and postsurvey analysis of student learning gains across two iterations of the course (2012-2013) revealed significantly higher student confidence in laboratory skills following the completion of the ALURE (p < 0.05 using the Mann-Whitney U-test). Learning objectives on effective scientific communication were also met through effective student performance in laboratory reports describing the research outcomes of the project. The integration of undergraduate research in clinical microbiology has the capacity to deliver authentic research experiences and improve scientific training for large cohorts of undergraduate students.

  1. A laboratory nanoseismological study on deep-focus earthquake micromechanics

    PubMed Central

    Wang, Yanbin; Zhu, Lupei; Shi, Feng; Schubnel, Alexandre; Hilairet, Nadege; Yu, Tony; Rivers, Mark; Gasc, Julien; Addad, Ahmed; Deldicque, Damien; Li, Ziyu; Brunet, Fabrice

    2017-01-01

    Global earthquake occurring rate displays an exponential decay down to ~300 km and then peaks around 550 to 600 km before terminating abruptly near 700 km. How fractures initiate, nucleate, and propagate at these depths remains one of the greatest puzzles in earth science, as increasing pressure inhibits fracture propagation. We report nanoseismological analysis on high-resolution acoustic emission (AE) records obtained during ruptures triggered by partial transformation from olivine to spinel in Mg2GeO4, an analog to the dominant mineral (Mg,Fe)2SiO4 olivine in the upper mantle, using state-of-the-art seismological techniques, in the laboratory. AEs’ focal mechanisms, as well as their distribution in both space and time during deformation, are carefully analyzed. Microstructure analysis shows that AEs are produced by the dynamic propagation of shear bands consisting of nanograined spinel. These nanoshear bands have a near constant thickness (~100 nm) but varying lengths and self-organize during deformation. This precursory seismic process leads to ultimate macroscopic failure of the samples. Several source parameters of AE events were extracted from the recorded waveforms, allowing close tracking of event initiation, clustering, and propagation throughout the deformation/transformation process. AEs follow the Gutenberg-Richter statistics with a well-defined b value of 1.5 over three orders of moment magnitudes, suggesting that laboratory failure processes are self-affine. The seismic relation between magnitude and rupture area correctly predicts AE magnitude at millimeter scales. A rupture propagation model based on strain localization theory is proposed. Future numerical analyses may help resolve scaling issues between laboratory AE events and deep-focus earthquakes. PMID:28776024

  2. Automated cellular sample preparation using a Centrifuge-on-a-Chip.

    PubMed

    Mach, Albert J; Kim, Jae Hyun; Arshi, Armin; Hur, Soojung Claire; Di Carlo, Dino

    2011-09-07

    The standard centrifuge is a laboratory instrument widely used by biologists and medical technicians for preparing cell samples. Efforts to automate the operations of concentration, cell separation, and solution exchange that a centrifuge performs in a simpler and smaller platform have had limited success. Here, we present a microfluidic chip that replicates the functions of a centrifuge without moving parts or external forces. The device operates using a purely fluid dynamic phenomenon in which cells selectively enter and are maintained in microscale vortices. Continuous and sequential operation allows enrichment of cancer cells from spiked blood samples at the mL min(-1) scale, followed by fluorescent labeling of intra- and extra-cellular antigens on the cells without the need for manual pipetting and washing steps. A versatile centrifuge-analogue may open opportunities in automated, low-cost and high-throughput sample preparation as an alternative to the standard benchtop centrifuge in standardized clinical diagnostics or resource poor settings.

  3. Comparison of Two Methods for the Isolation of Salmonellae From Imported Foods

    PubMed Central

    Taylor, Welton I.; Hobbs, Betty C.; Smith, Muriel E.

    1964-01-01

    Two methods for the detection of salmonellae in foods were compared in 179 imported meat and egg samples. The number of positive samples and replications, and the number of strains and kinds of serotypes were statistically comparable by both the direct enrichment method of the Food Hygiene Laboratory in England, and the pre-enrichment method devised for processed foods in the United States. Boneless frozen beef, veal, and horsemeat imported from five countries for consumption in England were found to have salmonellae present in 48 of 116 (41%) samples. Dried egg products imported from three countries were observed to have salmonellae in 10 of 63 (16%) samples. The high incidence of salmonellae isolated from imported foods illustrated the existence of an international health hazard resulting from the continuous introduction of exogenous strains of pathogenic microorganisms on a large scale. PMID:14106941

  4. Work plan for determining the occurrence of glyphosate, its transformation product AMPA, other herbicide compounds, and antibiotics in midwestern United States streams, 2002

    USGS Publications Warehouse

    Battaglin, W.A.; Thurman, E.M.; Kolpin, D.W.; Scribner, E.A.; Sandstrom, M.W.; Kuivila, K.M.

    2003-01-01

    The objective of this study is to determine the distribution of glyphosate and its primary transformation product aminomethylphosphonic acid (AMPA) in midwestern streams during post-application and harvest-season runoff events. Water samples will be collected in 2002 during two post-herbicide-application runoff events and one harvest-season runoff event from 53 sites on streams in the Midwestern United States. All samples will be analyzed at the U.S. Geological Survey Organic Geochemistry Research Laboratory in Lawrence, Kansas, for glyphosate and 20 other herbicides. Samples will also be analyzed for a glyphosate transformation product (AMPA) and 26 other herbicide transformation products, using GC/MS or HPLC/MS. Selected samples will be analyzed for 36 antibiotics or antibiotic transformational products. Results from this study will represent the first broad-scale investigation of glyphosate and AMPA in U.S. water resources.

  5. Identification of new transformation products during enzymatic treatment of tetracycline and erythromycin antibiotics at laboratory scale by an on-line turbulent flow liquid-chromatography coupled to a high resolution mass spectrometer LTQ-Orbitrap.

    PubMed

    Llorca, Marta; Rodríguez-Mozaz, Sara; Couillerot, Olivier; Panigoni, Karine; de Gunzburg, Jean; Bayer, Sally; Czaja, Rico; Barceló, Damià

    2015-01-01

    This work describes the formation of transformation products (TPs) by the enzymatic degradation at laboratory scale of two highly consumed antibiotics: tetracycline (Tc) and erythromycin (ERY). The analysis of the samples was carried out by a fast and simple method based on the novel configuration of the on-line turbulent flow system coupled to a hybrid linear ion trap - high resolution mass spectrometer. The method was optimized and validated for the complete analysis of ERY, Tc and their transformation products within 10 min without any other sample manipulation. Furthermore, the applicability of the on-line procedure was evaluated for 25 additional antibiotics, covering a wide range of chemical classes in different environmental waters with satisfactory quality parameters. Degradation rates obtained for Tc by laccase enzyme and ERY by EreB esterase enzyme without the presence of mediators were ∼78% and ∼50%, respectively. Concerning the identification of TPs, three suspected compounds for Tc and five of ERY have been proposed. In the case of Tc, the tentative molecular formulas with errors mass within 2 ppm have been based on the hypothesis of dehydroxylation, (bi)demethylation and oxidation of the rings A and C as major reactions. In contrast, the major TP detected for ERY has been identified as the "dehydration ERY-A", with the same molecular formula of its parent compound. In addition, the evaluation of the antibiotic activity of the samples along the enzymatic treatments showed a decrease around 100% in both cases. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Museum genomics: low-cost and high-accuracy genetic data from historical specimens.

    PubMed

    Rowe, Kevin C; Singhal, Sonal; Macmanes, Matthew D; Ayroles, Julien F; Morelli, Toni Lyn; Rubidge, Emily M; Bi, Ke; Moritz, Craig C

    2011-11-01

    Natural history collections are unparalleled repositories of geographical and temporal variation in faunal conditions. Molecular studies offer an opportunity to uncover much of this variation; however, genetic studies of historical museum specimens typically rely on extracting highly degraded and chemically modified DNA samples from skins, skulls or other dried samples. Despite this limitation, obtaining short fragments of DNA sequences using traditional PCR amplification of DNA has been the primary method for genetic study of historical specimens. Few laboratories have succeeded in obtaining genome-scale sequences from historical specimens and then only with considerable effort and cost. Here, we describe a low-cost approach using high-throughput next-generation sequencing to obtain reliable genome-scale sequence data from a traditionally preserved mammal skin and skull using a simple extraction protocol. We show that single-nucleotide polymorphisms (SNPs) from the genome sequences obtained independently from the skin and from the skull are highly repeatable compared to a reference genome. © 2011 Blackwell Publishing Ltd.

  7. Plasma creatinine in dogs: intra- and inter-laboratory variation in 10 European veterinary laboratories

    PubMed Central

    2011-01-01

    Background There is substantial variation in reported reference intervals for canine plasma creatinine among veterinary laboratories, thereby influencing the clinical assessment of analytical results. The aims of the study was to determine the inter- and intra-laboratory variation in plasma creatinine among 10 veterinary laboratories, and to compare results from each laboratory with the upper limit of its reference interval. Methods Samples were collected from 10 healthy dogs, 10 dogs with expected intermediate plasma creatinine concentrations, and 10 dogs with azotemia. Overlap was observed for the first two groups. The 30 samples were divided into 3 batches and shipped in random order by postal delivery for plasma creatinine determination. Statistical testing was performed in accordance with ISO standard methodology. Results Inter- and intra-laboratory variation was clinically acceptable as plasma creatinine values for most samples were usually of the same magnitude. A few extreme outliers caused three laboratories to fail statistical testing for consistency. Laboratory sample means above or below the overall sample mean, did not unequivocally reflect high or low reference intervals in that laboratory. Conclusions In spite of close analytical results, further standardization among laboratories is warranted. The discrepant reference intervals seem to largely reflect different populations used in establishing the reference intervals, rather than analytical variation due to different laboratory methods. PMID:21477356

  8. An efficient laboratory workflow for environmental risk assessment of organic chemicals.

    PubMed

    Zhu, Linyan; Santiago-Schübel, Beatrix; Xiao, Hongxia; Thiele, Björn; Zhu, Zhiliang; Qiu, Yanling; Hollert, Henner; Küppers, Stephan

    2015-07-01

    In this study, we demonstrate a fast and efficient workflow to investigate the transformation mechanism of organic chemicals and evaluate the toxicity of their transformation products (TPs) in laboratory scale. The transformation process of organic chemicals was first simulated by electrochemistry coupled online to mass spectrometry (EC-MS). The simulated reactions were scaled up in a batch EC reactor to receive larger amounts of a reaction mixture. The mixture sample was purified and concentrated by solid phase extraction (SPE) for the further ecotoxicological testing. The combined toxicity of the reaction mixture was evaluated in fish egg test (FET) (Danio rerio) compared to the parent compound. The workflow was verified with carbamazepine (CBZ). By using EC-MS seven primary TPs of CBZ were identified; the degradation mechanism was elucidated and confirmed by comparison to literature. The reaction mixture and one primary product (acridine) showed higher ecotoxicity in fish egg assay with 96 h EC50 values of 1.6 and 1.0 mg L(-1) than CBZ with the value of 60.8 mg L(-1). The results highlight the importance of transformation mechanism study and toxicological effect evaluation for organic chemicals brought into the environment since transformation of them may increase the toxicity. The developed process contributes a fast and efficient laboratory method for the risk assessment of organic chemicals and their TPs. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Investigation of differences between field and laboratory pH measurements of national atmospheric deposition program/national trends network precipitation samples

    USGS Publications Warehouse

    Latysh, N.; Gordon, J.

    2004-01-01

    A study was undertaken to investigate differences between laboratory and field pH measurements for precipitation samples collected from 135 weekly precipitation-monitoring sites in the National Trends Network from 12/30/1986 to 12/28/1999. Differences in pH between field and laboratory measurements occurred for 96% of samples collected during this time period. Differences between the two measurements were evaluated for precipitation samples collected before and after January 1994, when modifications to sample-handling protocol and elimination of the contaminating bucket o-ring used in sample shipment occurred. Median hydrogen-ion and pH differences between field and laboratory measurements declined from 3.9 ??eq L-1 or 0.10 pH units before the 1994 protocol change to 1.4 ??eq L-1 or 0.04 pH units after the 1994 protocol change. Hydrogen-ion differences between field and laboratory measurements had a high correlation with the sample pH determined in the field. The largest pH differences between the two measurements occurred for high-pH samples (>5.6), typical of precipitation collected in Western United States; however low- pH samples (<5.0) displayed the highest variability in hydrogen-ion differences between field and laboratory analyses. Properly screened field pH measurements are a useful alternative to laboratory pH values for trend analysis, particularly before 1994 when laboratory pH values were influenced by sample-collection equipment.

  10. Analysis of ground water by different laboratories: a comparison of chloride and nitrate data, Nassau and Suffolk counties, New York

    USGS Publications Warehouse

    Katz, Brian G.; Krulikas, Richard K.

    1979-01-01

    Water samples from wells in Nassau and Suffolk Counties were analyzed for chloride and nitrate. Two samples were collected at each well; one was analyzed by the U.S. Geological Survey, the other by a laboratory in the county from which the sample was taken. Results were compared statistically by paired-sample t-test to indicate the degree of uniformity among laboratory results. Chloride analyses from one of the three county laboratories differed significantly (0.95 confidence level) from that of a Geological Survey laboratory. For nitrate analyses, a significant difference (0.95 confidence level) was noted between results from two of the three county laboratories and the Geological Survey laboratory. The lack of uniformity among results reported by the participating laboratories indicates a need for continuing participation in a quality-assurance program and exercise of strong quality control from time of sample collection through analysis so that differences can be evaluated. (Kosco-USGS)

  11. Comparing hair-morphology and molecular methods to identify fecal samples from Neotropical felids

    PubMed Central

    Alberts, Carlos C.; Saranholi, Bruno H.; Frei, Fernando; Galetti, Pedro M.

    2017-01-01

    To avoid certain problems encountered with more-traditional and invasive methods in behavioral-ecology studies of mammalian predators, such as felids, molecular approaches have been employed to identify feces found in the field. However, this method requires a complete molecular biology laboratory, and usually also requires very fresh fecal samples to avoid DNA degradation. Both conditions are normally absent in the field. To address these difficulties, identification based on morphological characters (length, color, banding, scales and medullar patterns) of hairs found in feces could be employed as an alternative. In this study we constructed a morphological identification key for guard hairs of eight Neotropical felids (jaguar, oncilla, Geoffroy’s cat, margay, ocelot, Pampas cat, puma and jaguarundi) and compared its efficiency to that of a molecular identification method, using the ATP6 region as a marker. For this molecular approach, we simulated some field conditions by postponing sample-conservation procedures. A blind test of the identification key obtained a nearly 70% overall success rate, which we considered equivalent to or better than the results of some molecular methods (probably due to DNA degradation) found in other studies. The jaguar, puma and jaguarundi could be unequivocally discriminated from any other Neotropical felid. On a scale ranging from inadequate to excellent, the key proved poor only for the margay, with only 30% of its hairs successfully identified using this key; and have intermediate success rates for the remaining species, the oncilla, Geoffroy’s cat, ocelot and Pampas cat, were intermediate. Complementary information about the known distributions of felid populations may be necessary to substantially improve the results obtained with the key. Our own molecular results were even better, since all blind-tested samples were correctly identified. Part of these identifications were made from samples kept in suboptimal conditions, with some samples remaining outdoors for up to seven days, simulating conditions in the field. It appears that both methods can be used, depending on the available laboratory facilities and on the expected results. PMID:28880947

  12. Application of a low-cost web-based simulation to improve students' practical skills in medical education.

    PubMed

    Moreno-Ger, Pablo; Torrente, Javier; Bustamante, Julián; Fernández-Galaz, Carmen; Fernández-Manjón, Baltasar; Comas-Rengifo, María Dolores

    2010-06-01

    Practical sessions in undergraduate medical education are often costly and have to face constraints in terms of available laboratory time and practice materials (e.g. blood samples from animals). This makes it difficult to increase the time each student spends at the laboratory. We consider that it would be possible to improve the effectiveness of the laboratory time by providing the students with computer-based simulations for prior rehearsal. However, this approach still presents issues in terms of development costs and distribution to the students. This study investigates the employment of low-cost simulation to allow medical students to rehearse practical exercises through a web-based e-learning environment. The aim is to maximize the efficiency of laboratory time and resources allocated by letting students become familiarized with the equipment and the procedures before they attend a laboratory session, but without requiring large-scale investment. Moreover, students can access the simulation via the Internet and rehearse at their own pace. We have studied the effects of such a simulation in terms of impact on the laboratory session, learning outcomes and student satisfaction. We created a simulation that covers the steps of a practical exercise in a Physiology course (measuring hematocrit in a blood sample). An experimental group (EG, n=66) played the simulation 1 week before the laboratory session. A control group (CG, n=77) attended the laboratory session without playing the simulation. After the session, all students completed a survey about their perception of the difficulty of the exercise on a scale of 1-10 and the HCT final value that they obtained. The students in the EG also completed a survey about their satisfaction with the experience. After the laboratory session, the perceived difficulty of the procedure was lower on average in the EG compared to the CG (3.52 vs. 4.39, 95% CI: 0.16-1.57, P=.016). There was no significant difference in terms of perceived difficulty using the equipment. The HCT measures reported by the EG group also presented a much lower dispersion, meaning a higher reliability, in determining the HCT value (3.10 vs. 26.94, SD; variances significantly different, P<.001, F: 75.25, Dfd: 68.19 for EG and CG). In the satisfaction test, the majority of the students in the EG reported that the experience was positive or very positive (80.7%) and reported that it had helped them to identify and use the equipment (78%) and to perform the exercise (66%). The simulation was well received by students in the EG, who felt more comfortable during the laboratory session, and it helped them to perform the exercise better, obtaining more accurate results, which indicates more effective training. EG students perceived the procedure as easier to perform, but did not report an improvement in the perceived difficulty in using the equipment. The increased reliability demonstrates that low-cost simulations are a good complement to the laboratory sessions. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  13. Comparison of different pressing techniques for the preparation of n-type silicon-germanium thermoelectric alloys

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harringa, J.L.; Cook, B.A.

    1996-06-01

    Improvements to state-of-the-art Si{sub 80}Ge{sub 20} thermoelectric alloys have been observed in laboratory-scale samples by the powder metallurgy techniques of mechanical alloying and hot pressing. Incorporating these improvements in large scale compacts for the production of thermoelectric generator elements is the next step in achieving higher efficiency RTGs. This paper discusses consolidation of large quantities of mechanically alloyed powders into production size compacts. Differences in thermoelectric properties are noted between the compacts prepared by the standard technique of hot uniaxial pressing and hot isostatic pressing. Most significant is the difference in carrier concentration between the alloys prepared by the twomore » consolidation techniques.« less

  14. Application of lab derived kinetic biodegradation parameters at the field scale

    NASA Astrophysics Data System (ADS)

    Schirmer, M.; Barker, J. F.; Butler, B. J.; Frind, E. O.

    2003-04-01

    Estimating the intrinsic remediation potential of an aquifer typically requires the accurate assessment of the biodegradation kinetics, the level of available electron acceptors and the flow field. Zero- and first-order degradation rates derived at the laboratory scale generally overpredict the rate of biodegradation when applied to the field scale, because limited electron acceptor availability and microbial growth are typically not considered. On the other hand, field estimated zero- and first-order rates are often not suitable to forecast plume development because they may be an oversimplification of the processes at the field scale and ignore several key processes, phenomena and characteristics of the aquifer. This study uses the numerical model BIO3D to link the laboratory and field scale by applying laboratory derived Monod kinetic degradation parameters to simulate a dissolved gasoline field experiment at Canadian Forces Base (CFB) Borden. All additional input parameters were derived from laboratory and field measurements or taken from the literature. The simulated results match the experimental results reasonably well without having to calibrate the model. An extensive sensitivity analysis was performed to estimate the influence of the most uncertain input parameters and to define the key controlling factors at the field scale. It is shown that the most uncertain input parameters have only a minor influence on the simulation results. Furthermore it is shown that the flow field, the amount of electron acceptor (oxygen) available and the Monod kinetic parameters have a significant influence on the simulated results. Under the field conditions modelled and the assumptions made for the simulations, it can be concluded that laboratory derived Monod kinetic parameters can adequately describe field scale degradation processes, if all controlling factors are incorporated in the field scale modelling that are not necessarily observed at the lab scale. In this way, there are no scale relationships to be found that link the laboratory and the field scale, accurately incorporating the additional processes, phenomena and characteristics, such as a) advective and dispersive transport of one or more contaminants, b) advective and dispersive transport and availability of electron acceptors, c) mass transfer limitations and d) spatial heterogeneities, at the larger scale and applying well defined lab scale parameters should accurately describe field scale processes.

  15. The innovative osmotic membrane bioreactor (OMBR) for reuse of wastewater.

    PubMed

    Cornelissen, E R; Harmsen, D; Beerendonk, E F; Qin, J J; Oo, H; de Korte, K F; Kappelhof, J W M N

    2011-01-01

    An innovative osmotic membrane bioreactor (OMBR) is currently under development for the reclamation of wastewater, which combines activated sludge treatment and forward osmosis (FO) membrane separation with a RO post-treatment. The research focus is FO membrane fouling and performance using different activated sludge investigated both at laboratory scale (membrane area of 112cm2) and at on-site bench scale (flat sheet membrane area of 0.1 m2). FO performance on laboratory-scale (i) increased with temperature due to a decrease in viscosity and (ii) was independent of the type of activated sludge. Draw solution leakage increased with temperature and varied for different activated sludge. FO performance on bench-scale (i) increased with osmotic driving force, (ii) depended on the membrane orientation due to internal concentration polarization and (iii) was invariant to feed flow decrease and air injection at the feed and draw side. Draw solution leakage could not be evaluated on bench-scale due to experimental limitation. Membrane fouling was not found on laboratory scale and bench-scale, however, partially reversible fouling was found on laboratory scale for FO membranes facing the draw solution. Economic assessment indicated a minimum flux of 15L.m-2 h-1 at 0.5M NaCl for OMBR-RO to be cost effective, depending on the FO membrane price.

  16. Bias from two analytical laboratories involved in a long-term air monitoring program measuring organic pollutants in the Arctic: a quality assurance/quality control assessment.

    PubMed

    Su, Yushan; Hung, Hayley; Stern, Gary; Sverko, Ed; Lao, Randy; Barresi, Enzo; Rosenberg, Bruno; Fellin, Phil; Li, Henrik; Xiao, Hang

    2011-11-01

    Initiated in 1992, air monitoring of organic pollutants in the Canadian Arctic provided spatial and temporal trends in support of Canada's participation in the Stockholm Convention of Persistent Organic Pollutants. The specific analytical laboratory charged with this task was changed in 2002 while field sampling protocols remained unchanged. Three rounds of intensive comparison studies were conducted in 2004, 2005, and 2008 to assess data comparability between the two laboratories. Analysis was compared for organochlorine pesticides (OCPs), polychlorinated biphenyls (PCBs) and polycyclic aromatic hydrocarbons (PAHs) in standards, blind samples of mixed standards and extracts of real air samples. Good measurement accuracy was achieved for both laboratories when standards were analyzed. Variation of measurement accuracy over time was found for some OCPs and PCBs in standards on a random and non-systematic manner. Relatively low accuracy in analyzing blind samples was likely related to the process of sample purification. Inter-laboratory measurement differences for standards (<30%) and samples (<70%) were generally less than or comparable to those reported in a previous inter-laboratory study with 21 participating laboratories. Regression analysis showed inconsistent data comparability between the two laboratories during the initial stages of the study. These inter-laboratory differences can complicate abilities to discern long-term trends of pollutants in a given sampling site. It is advisable to maintain long-term measurements with minimal changes in sample analysis.

  17. Acceleration to failure in geophysical signals prior to laboratory rock failure and volcanic eruptions (Invited)

    NASA Astrophysics Data System (ADS)

    Main, I. G.; Bell, A. F.; Greenhough, J.; Heap, M. J.; Meredith, P. G.

    2010-12-01

    The nucleation processes that ultimately lead to earthquakes, volcanic eruptions, rock bursts in mines, and landslides from cliff slopes are likely to be controlled at some scale by brittle failure of the Earth’s crust. In laboratory brittle deformation experiments geophysical signals commonly exhibit an accelerating trend prior to dynamic failure. Similar signals have been observed prior to volcanic eruptions, including volcano-tectonic earthquake event and moment release rates. Despite a large amount of effort in the search, no such statistically robust systematic trend is found prior to natural earthquakes. Here we describe the results of a suite of laboratory tests on Mount Etna Basalt and other rocks to examine the nature of the non-linear scaling from laboratory to field conditions, notably using laboratory ‘creep’ tests to reduce the boundary strain rate to conditions more similar to those in the field. Seismic event rate, seismic moment release rate and rate of porosity change show a classic ‘bathtub’ graph that can be derived from a simple damage model based on separate transient and accelerating sub-critical crack growth mechanisms, resulting from separate processes of negative and positive feedback in the population dynamics. The signals exhibit clear precursors based on formal statistical model tests using maximum likelihood techniques with Poisson errors. After correcting for the finite loading time of the signal, the results show a transient creep rate that decays as a classic Omori law for earthquake aftershocks, and remarkably with an exponent near unity, as commonly observed for natural earthquake sequences. The accelerating trend follows an inverse power law when fitted in retrospect, i.e. with prior knowledge of the failure time. In contrast the strain measured on the sample boundary shows a less obvious but still accelerating signal that is often absent altogether in natural strain data prior to volcanic eruptions. To test the forecasting power of such constitutive rules in prospective mode, we examine the forecast quality of several synthetic trials, by adding representative statistical fluctuations, due to finite real-time sampling effects, to an underlying accelerating trend. Metrics of forecast quality change systematically and dramatically with time. In particular the model accuracy increases, and the forecast bias decreases, as the failure time approaches.

  18. [User's requests (from a practitioner's perspective)].

    PubMed

    Ohnishi, T

    1997-08-01

    As a practitioner, I have to rely on outside clinical laboratories and affiliated hospitals to perform laboratory tests. In this abstract, I describe specific problems I have encountered with third-party laboratories, and propose solutions for these problems to optimize use of laboratory tests. BLOOD TESTS: The most frequent problem in ordering blood tests is the lack of detailed information regarding sampling conditions. I often have to call laboratories to check whether the sample should be serum or plasma, what volume is needed, whether the sample should be cooled, etc. I propose that clinical laboratories should provide practitioners' manuals that describe specific sampling information. Most laboratories do not keep the data from ultrasonographic tests. The lack of these is most problematic when test results are interpreted differently by laboratories and by practitioners. Retaining the data would also help private laboratories improve the quality of the test by enabling them to compare their interpretations with others'. ANNUAL MEDICAL SCREENING: Even if an abnormal finding is detected at medical screening clinics, the final diagnosis is usually not sent back to the screening facilities. This is highly recommended to establish an official system that mediates the feedback to screening centers. MRI: Due to miscommunication between practitioners and radiologists, the test is sometimes performed inappropriately. A thorough consultation should occur before the test to clarify specific goals for each patient. PATHOLOGICAL TESTS: Interpretation of results is often inconsistent among laboratories. Independent clinical laboratories tend to report results without indicating sample problems, while pathology departments at affiliated hospitals tend to emphasize sample problems instead of diagnosis or suggesting ways to improve sample quality. Mutual communication among laboratories would help standardize the quality of pathological tests.

  19. Spatial and temporal variability of hyperspectral signatures of terrain

    NASA Astrophysics Data System (ADS)

    Jones, K. F.; Perovich, D. K.; Koenig, G. G.

    2008-04-01

    Electromagnetic signatures of terrain exhibit significant spatial heterogeneity on a range of scales as well as considerable temporal variability. A statistical characterization of the spatial heterogeneity and spatial scaling algorithms of terrain electromagnetic signatures are required to extrapolate measurements to larger scales. Basic terrain elements including bare soil, grass, deciduous, and coniferous trees were studied in a quasi-laboratory setting using instrumented test sites in Hanover, NH and Yuma, AZ. Observations were made using a visible and near infrared spectroradiometer (350 - 2500 nm) and hyperspectral camera (400 - 1100 nm). Results are reported illustrating: i) several difference scenes; ii) a terrain scene time series sampled over an annual cycle; and iii) the detection of artifacts in scenes. A principal component analysis indicated that the first three principal components typically explained between 90 and 99% of the variance of the 30 to 40-channel hyperspectral images. Higher order principal components of hyperspectral images are useful for detecting artifacts in scenes.

  20. Community Structure of Lithotrophically-Driven Hydrothermal Microbial Mats from the Mariana Arc and Back-Arc

    PubMed Central

    Hager, Kevin W.; Fullerton, Heather; Butterfield, David A.; Moyer, Craig L.

    2017-01-01

    The Mariana region exhibits a rich array of hydrothermal venting conditions in a complex geological setting, which provides a natural laboratory to study the influence of local environmental conditions on microbial community structure as well as large-scale patterns in microbial biogeography. We used high-throughput amplicon sequencing of the bacterial small subunit (SSU) rRNA gene from 22 microbial mats collected from four hydrothermally active locations along the Mariana Arc and back-arc to explore the structure of lithotrophically-based microbial mat communities. The vent effluent was classified as iron- or sulfur-rich corresponding with two distinct community types, dominated by either Zetaproteobacteria or Epsilonproteobacteria, respectively. The Zetaproteobacterial-based communities had the highest richness and diversity, which supports the hypothesis that Zetaproteobacteria function as ecosystem engineers creating a physical habitat within a chemical environment promoting enhanced microbial diversity. Gammaproteobacteria were also high in abundance within the iron-dominated mats and some likely contribute to primary production. In addition, we also compare sampling scale, showing that bulk sampling of microbial mats yields higher diversity than micro-scale sampling. We present a comprehensive analysis and offer new insights into the community structure and diversity of lithotrophically-driven microbial mats from a hydrothermal region associated with high microbial biodiversity. Our study indicates an important functional role of for the Zetaproteobacteria altering the mat habitat and enhancing community interactions and complexity. PMID:28970817

  1. DEVELOPMENT AND DEPLOYMENT OF VACUUM SALT DISTILLATION AT THE SAVANNAH RIVER SITE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pierce, R.; Pak, D.; Edwards, T.

    2010-10-28

    The Savannah River Site has a mission to dissolve fissile materials and disposition them. The primary fissile material is plutonium dioxide (PuO{sub 2}). To support dissolution of these materials, the Savannah River National Laboratory (SRNL) designed and demonstrated a vacuum salt distillation (VSD) apparatus using both representative radioactive samples and non-radioactive simulant materials. Vacuum salt distillation, through the removal of chloride salts, increases the quantity of materials suitable for processing in the site's HB-Line Facility. Small-scale non-radioactive experiments at 900-950 C show that >99.8 wt % of the initial charge of chloride salt distilled from the sample boat with recoverymore » of >99.8 wt % of the ceric oxide (CeO{sub 2}) - the surrogate for PuO{sub 2} - as a non-chloride bearing 'product'. Small-scale radioactive testing in a glovebox demonstrated the removal of sodium chloride (NaCl) and potassium chloride (KCl) from 13 PuO{sub 2} samples. Chloride concentrations were distilled from a starting concentration of 1.8-10.8 wt % to a final concentration <500 mg/kg chloride. Initial testing of a non-radioactive, full-scale production prototype is complete. A designed experiment evaluated the impact of distillation temperature, time at temperature, vacuum, product depth, and presence of a boat cover. Significant effort has been devoted to mechanical considerations to facilitate simplified operation in a glovebox.« less

  2. Probing the Reproducibility of Leaf Growth and Molecular Phenotypes: A Comparison of Three Arabidopsis Accessions Cultivated in Ten Laboratories1[W

    PubMed Central

    Massonnet, Catherine; Vile, Denis; Fabre, Juliette; Hannah, Matthew A.; Caldana, Camila; Lisec, Jan; Beemster, Gerrit T.S.; Meyer, Rhonda C.; Messerli, Gaëlle; Gronlund, Jesper T.; Perkovic, Josip; Wigmore, Emma; May, Sean; Bevan, Michael W.; Meyer, Christian; Rubio-Díaz, Silvia; Weigel, Detlef; Micol, José Luis; Buchanan-Wollaston, Vicky; Fiorani, Fabio; Walsh, Sean; Rinn, Bernd; Gruissem, Wilhelm; Hilson, Pierre; Hennig, Lars; Willmitzer, Lothar; Granier, Christine

    2010-01-01

    A major goal of the life sciences is to understand how molecular processes control phenotypes. Because understanding biological systems relies on the work of multiple laboratories, biologists implicitly assume that organisms with the same genotype will display similar phenotypes when grown in comparable conditions. We investigated to what extent this holds true for leaf growth variables and metabolite and transcriptome profiles of three Arabidopsis (Arabidopsis thaliana) genotypes grown in 10 laboratories using a standardized and detailed protocol. A core group of four laboratories generated similar leaf growth phenotypes, demonstrating that standardization is possible. But some laboratories presented significant differences in some leaf growth variables, sometimes changing the genotype ranking. Metabolite profiles derived from the same leaf displayed a strong genotype × environment (laboratory) component. Genotypes could be separated on the basis of their metabolic signature, but only when the analysis was limited to samples derived from one laboratory. Transcriptome data revealed considerable plant-to-plant variation, but the standardization ensured that interlaboratory variation was not considerably larger than intralaboratory variation. The different impacts of the standardization on phenotypes and molecular profiles could result from differences of temporal scale between processes involved at these organizational levels. Our findings underscore the challenge of describing, monitoring, and precisely controlling environmental conditions but also demonstrate that dedicated efforts can result in reproducible data across multiple laboratories. Finally, our comparative analysis revealed that small variations in growing conditions (light quality principally) and handling of plants can account for significant differences in phenotypes and molecular profiles obtained in independent laboratories. PMID:20200072

  3. Inter-laboratory comparison of radiometric culture for Mycobacterium avium subsp. paratuberculosis using raw milk from known infected herds and individual dairy cattle in Victoria.

    PubMed

    Ridge, S E; Andreata, S; Jones, K; Cantlon, K; Francis, B; Florisson, N; Gwozdz, J

    2010-07-01

    To compare the results of radiometric culture conducted in three Australian laboratories for Mycobacterium avium subsp. paratuberculosis (Mptb) using bulk vat and individual animal milk samples. Milk samples were collected from 15 cows exhibiting clinical signs of Johne's disease, and subsequently confirmed as infected with Mptb, and from the bulk milk vats on 91 farms running herds known to be infected with Mptb. Each milk sample was divided into three equivalent samples and one of each of the replicates was forwarded to the three participating laboratories. The identity and nature of the samples was protected from the study collaborators. The laboratories processed the samples and undertook radiometric culture for Mptb using their standard method. Results of testing were provided to the principal investigator for collation and analysis. In total, 2 (2.2%) of 91 vat-milk samples and 8 (53.3%) of 15 individual cows' milk samples returned positive radiometric milk culture results. Only one sample, from a clinical case of Johne's disease, was identified as positive by more than one laboratory. There were differences in the absolute frequency with which Mptb was identified in the milk samples by the collaborating laboratories. Mptb was cultured from a very small percentage of Australian raw bulk milk samples sourced from known infected herds. By contrast, Mptb was successfully cultured from half of the milk samples collected from clinically affected cows. There was no statistical difference between laboratories in the proportion of vat samples or individual animal milk samples in which Mptb was detected.

  4. Hyporheic less-mobile porosity and solute transport in porous media

    NASA Astrophysics Data System (ADS)

    MahmoodPoorDehkordy, F.; Briggs, M. A.; Day-Lewis, F. D.; Scruggs, C.; Singha, K.; Zarnetske, J. P.; Lane, J. W., Jr.; Bagtzoglou, A. C.

    2017-12-01

    Solute transport and reactive processes are strongly influenced by hydrodynamic exchange with the hyporheic zone. Contaminant transport and redox zonation in the hyporheic zone and near-stream aquifer can be impacted by the exchange between mobile and less-mobile porosity zones in heterogeneous porous media. Less-mobile porosity zones can be created by fine materials with tight pore throats (e.g. clay, organics) and in larger, well-connected pores down gradient of flow obstructions (e.g. sand behind cobbles). Whereas fluid sampling is primarily responsive to the more-mobile domain, tracking solute tracer dynamics by geoelectrical methods provides direct information about both more- and less-mobile zones. During tracer injection through porous media of varied pore connectivity, a lag between fluid and bulk electrical conductivity is observed, creating a hysteresis loop when plotted in conductivity space. Thus, the combination of simultaneous fluid and bulk electrical conductivity measurements enables a much improved quantification of less-mobile solute dynamics compared to traditional fluid-only sampling approaches. We have demonstrated the less-mobile porosity exchange in laboratory-scale column experiments verified by simulation models. The experimental approach has also been applied to streambed sediments in column and reach-scale field experiments and verified using numerical simulation. Properties of the resultant hysteresis loops can be used to estimate exchange parameters of less-mobile porosity. Our integrated approach combining field experiments, laboratory experiments, and numerical modeling provides new insights into the effect of less-mobile porosity on solute transport in the hyporheic zone.

  5. ENVIRONMENTAL BENIGN MITIGATION OF MICROBIOLOGICALLY INFLUENCED CORROSION (MIC)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J.R. Paterek; G. Husmillo; V. Trbovic

    The overall program objective is to develop and evaluate environmental benign agents or products that are effective in the prevention, inhibition, and mitigation of microbially influenced corrosion (MIC) in the internal surfaces of metallic natural gas pipelines. The goal is one or more environmental benign, a.k.a. ''green'' products that can be applied to maintain the structure and dependability of the natural gas infrastructure. The technical approach for this quarter were isolation and cultivation of MIC-causing microorganisms from corroded pipeline samples, optimizing parameters in the laboratory-scale corrosion test loop system and testing the effective concentrations of Capsicum sp. extracts to verifymore » the extent of corrosion on metal coupons by batch culture method. A total of 22 strains from the group of heterotrophic, acid producing, denitrifying and sulfate reducing bacteria were isolated from the gas pipeline samples obtained from Northern Indiana Public Service Company in Trenton, Indiana. They were purified and will be sent out for identification. Bacterial strains of interest were used in antimicrobial screenings and test loop experiments. Parameters for the laboratory-scale test loop system such as gas and culture medium flow rate; temperature; inoculation period; and length of incubation were established. Batch culture corrosion study against Desulfovibrio vulgaris showed that one (S{sub 1}M) out of the four Capsicum sp. extracts tested was effective in controlling the corrosion rate in metal coupons by 33.33% when compared to the untreated group.« less

  6. Crowdsourcing for Cognitive Science – The Utility of Smartphones

    PubMed Central

    Brown, Harriet R.; Zeidman, Peter; Smittenaar, Peter; Adams, Rick A.; McNab, Fiona; Rutledge, Robb B.; Dolan, Raymond J.

    2014-01-01

    By 2015, there will be an estimated two billion smartphone users worldwide. This technology presents exciting opportunities for cognitive science as a medium for rapid, large-scale experimentation and data collection. At present, cost and logistics limit most study populations to small samples, restricting the experimental questions that can be addressed. In this study we investigated whether the mass collection of experimental data using smartphone technology is valid, given the variability of data collection outside of a laboratory setting. We presented four classic experimental paradigms as short games, available as a free app and over the first month 20,800 users submitted data. We found that the large sample size vastly outweighed the noise inherent in collecting data outside a controlled laboratory setting, and show that for all four games canonical results were reproduced. For the first time, we provide experimental validation for the use of smartphones for data collection in cognitive science, which can lead to the collection of richer data sets and a significant cost reduction as well as provide an opportunity for efficient phenotypic screening of large populations. PMID:25025865

  7. Quantitative comparison of DNA methylation assays for biomarker development and clinical applications.

    PubMed

    2016-07-01

    DNA methylation patterns are altered in numerous diseases and often correlate with clinically relevant information such as disease subtypes, prognosis and drug response. With suitable assays and after validation in large cohorts, such associations can be exploited for clinical diagnostics and personalized treatment decisions. Here we describe the results of a community-wide benchmarking study comparing the performance of all widely used methods for DNA methylation analysis that are compatible with routine clinical use. We shipped 32 reference samples to 18 laboratories in seven different countries. Researchers in those laboratories collectively contributed 21 locus-specific assays for an average of 27 predefined genomic regions, as well as six global assays. We evaluated assay sensitivity on low-input samples and assessed the assays' ability to discriminate between cell types. Good agreement was observed across all tested methods, with amplicon bisulfite sequencing and bisulfite pyrosequencing showing the best all-round performance. Our technology comparison can inform the selection, optimization and use of DNA methylation assays in large-scale validation studies, biomarker development and clinical diagnostics.

  8. Crowdsourcing for cognitive science--the utility of smartphones.

    PubMed

    Brown, Harriet R; Zeidman, Peter; Smittenaar, Peter; Adams, Rick A; McNab, Fiona; Rutledge, Robb B; Dolan, Raymond J

    2014-01-01

    By 2015, there will be an estimated two billion smartphone users worldwide. This technology presents exciting opportunities for cognitive science as a medium for rapid, large-scale experimentation and data collection. At present, cost and logistics limit most study populations to small samples, restricting the experimental questions that can be addressed. In this study we investigated whether the mass collection of experimental data using smartphone technology is valid, given the variability of data collection outside of a laboratory setting. We presented four classic experimental paradigms as short games, available as a free app and over the first month 20,800 users submitted data. We found that the large sample size vastly outweighed the noise inherent in collecting data outside a controlled laboratory setting, and show that for all four games canonical results were reproduced. For the first time, we provide experimental validation for the use of smartphones for data collection in cognitive science, which can lead to the collection of richer data sets and a significant cost reduction as well as provide an opportunity for efficient phenotypic screening of large populations.

  9. Hair MDMA samples are consistent with reported ecstasy use: findings from a study investigating effects of ecstasy on mood and memory.

    PubMed

    Scholey, A B; Owen, L; Gates, J; Rodgers, J; Buchanan, T; Ling, J; Heffernan, T; Swan, P; Stough, C; Parrott, A C

    2011-01-01

    Our group has conducted several Internet investigations into the biobehavioural effects of self-reported recreational use of MDMA (3,4-methylenedioxymethamphetamine or Ecstasy) and other psychosocial drugs. Here we report a new study examining the relationship between self-reported Ecstasy use and traces of MDMA found in hair samples. In a laboratory setting, 49 undergraduate volunteers performed an Internet-based assessment which included mood scales and the University of East London Drug Use Questionnaire, which asks for history and current drug use. They also provided a hair sample for determination of exposure to MDMA over the previous month. Self-report of Ecstasy use and presence in hair samples were consistent (p < 0.00001). Both subjective and objective measures predicted lower self-reported ratings of happiness and higher self-reported stress. Self-reported Ecstasy use, but not presence in hair, was also associated with decreased tension. Different psychoactive drugs can influence long-term mood and cognition in complex and dynamically interactive ways. Here we have shown a good correspondence between self-report and objective assessment of exposure to MDMA. These data suggest that the Internet has potentially high utility as a useful medium to complement traditional laboratory studies into the sequelae of recreational drug use. Copyright © 2010 S. Karger AG, Basel.

  10. LABORATORY SCALE STEAM INJECTION TREATABILITY STUDIES

    EPA Science Inventory

    Laboratory scale steam injection treatability studies were first developed at The University of California-Berkeley. A comparable testing facility has been developed at USEPA's Robert S. Kerr Environmental Research Center. Experience has already shown that many volatile organic...

  11. Validation of laboratory-scale recycling test method of paper PSA label products

    Treesearch

    Carl Houtman; Karen Scallon; Richard Oldack

    2008-01-01

    Starting with test methods and a specification developed by the U.S. Postal Service (USPS) Environmentally Benign Pressure Sensitive Adhesive Postage Stamp Program, a laboratory-scale test method and a specification were developed and validated for pressure-sensitive adhesive labels, By comparing results from this new test method and pilot-scale tests, which have been...

  12. Slow Slip and Earthquake Nucleation in Meter-Scale Laboratory Experiments

    NASA Astrophysics Data System (ADS)

    Mclaskey, G.

    2017-12-01

    The initiation of dynamic rupture is thought to be preceded by a quasistatic nucleation phase. Observations of recent earthquakes sometimes support this by illuminating slow slip and foreshocks in the vicinity of the eventual hypocenter. I describe laboratory earthquake experiments conducted on two large-scale loading machines at Cornell University that provide insight into the way earthquake nucleation varies with normal stress, healing time, and loading rate. The larger of the two machines accommodates a 3 m long granite sample, and when loaded to 7 MPa stress levels, we observe dynamic rupture events that are preceded by a measureable nucleation zone with dimensions on the order of 1 m. The smaller machine accommodates a 0.76 m sample that is roughly the same size as the nucleation zone. On this machine, small variations in nucleation properties result in measurable differences in slip events, and we generate both dynamic rupture events (> 0.1 m/s slip rates) and slow slip events ( 0.001 to 30 mm/s slip rates). Slow events occur when instability cannot fully nucleate before reaching the sample ends. Dynamic events occur after long healing times or abrupt increases in loading rate which suggests that these factors shrink the spatial and temporal extents of the nucleation zone. Arrays of slip, strain, and ground motion sensors installed on the sample allow us to quantify seismic coupling and study details of premonitory slip and afterslip. The slow slip events we observe are primarily aseismic (less than 1% of the seismic coupling of faster events) and produce swarms of very small M -6 to M -8 events. These mechanical and seismic interactions suggest that faults with transitional behavior—where creep, small earthquakes, and tremor are often observed—could become seismically coupled if loaded rapidly, either by a slow slip front or dynamic rupture of an earthquake that nucleated elsewhere.

  13. Portable gamma spectrometry: measuring soil erosion in-situ at four Critical Zone Observatories in P. R. China

    NASA Astrophysics Data System (ADS)

    Sanderson, N. K.; Green, S. M.; Chen, Z.; Wang, J.; Wang, Y.; Wang, R.; Yu, K.; Tu, C.; Jia, X.; Li, G.; Peng, X.; Quine, T. A.

    2017-12-01

    Detecting patterns of soil erosion, redistribution, and/soil nutrient loss is important for long-term soil conservation and agricultural sustainability. Caesium-137 (137Cs) and other fallout radionuclide inventories have been used over the the last 50 years to track soil erosion, transport and deposition on a catchment scale, and have been shown to be useful for informing models of temporal/spatial soil redistribution. Traditional sampling methods usually involves coring, grinding, sieving, sub-sampling and laboratory analysis using HPGe detectors, all of which can be costly and time consuming. In-situ measurements can provide a mechanism for assessment of 137Cs over larger areas that integrate the spatial variability, and expand turnover of analyses. Here, we assess the applicability of an in-situ approach based on radionuclide principles, and provide a comparison of the two approaches: laboratory vs. in-situ. The UK-China Critical Zone Observatory (CZO) programme provides an ideal research platform to assess the in-situ approach to measuring soil erosion: using a portable gamma spectrometer to determine 137Cs inventories. Four extensive field slope surveys were conducted in the CZO's, which covers four ecosystem types in China: karst, red soil, peri-urban, and loess plateau. In each CZO, 3-6 plots were measured along 2 slope transects, with 3 replicated 1 hour counts of 137Cs in each plot. In addition, 137Cs soil depth and bulk density profiles were also sampled for each plot, and lab-derived inventories calculated using traditional methods for comparison. Accurately and rapidly measuring 137Cs inventories using a portable field detector allows for a greater coverage of sampling locations and the potential for small-scale spatial integration, as well as the ability to re-visit sites over time and continually adapt and improve soil erosion/redistribution models, thus more effectively targeting areas of interest with reduced cost and time constraints.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shull, H.E.

    The objective of the project was to investigate the economic feasibility of converting potato waste to fuel alcohol. The source of potato starch was Troyer Farms Potato Chips. Experimental work was carried out at both the laboratory scale and the larger pilot scale batch operation at a decommissioned waste water treatment building on campus. The laboratory scale work was considerably more extensive than originally planned, resulting in a much improved scientific work. The pilot scale facility has been completed and operated successfully. In contrast, the analysis of the economic feasibility of commercial production has not yet been completed. The projectmore » was brought to a close with the successful demonstration of the fermentation and distillation using the large scale facilities described previously. Two batches of mash were cooked using the procedures established in support of the laboratory scale work. One of the batches was fermented using the optimum values of the seven controlled factors as predicted by the laboratory scale application of the Box-Wilson design. The other batch was fermented under conditions derived out of Mr. Rouse's interpretation of his long sequence of laboratory results. He was gratified to find that his commitment to the Box-Wilson experiments was justified. The productivity of the Box-Wilson design was greater. The difference between the performance of the two fermentors (one stirred, one not) has not been established yet. Both batches were then distilled together, demonstrating the satisfactory performance of the column still. 4 references.« less

  15. Soil sampling strategies for site assessments in petroleum-contaminated areas.

    PubMed

    Kim, Geonha; Chowdhury, Saikat; Lin, Yen-Min; Lu, Chih-Jen

    2017-04-01

    Environmental site assessments are frequently executed for monitoring and remediation performance evaluation purposes, especially in total petroleum hydrocarbon (TPH)-contaminated areas, such as gas stations. As a key issue, reproducibility of the assessment results must be ensured, especially if attempts are made to compare results between different institutions. Although it is widely known that uncertainties associated with soil sampling are much higher than those with chemical analyses, field guides or protocols to deal with these uncertainties are not stipulated in detail in the relevant regulations, causing serious errors and distortion of the reliability of environmental site assessments. In this research, uncertainties associated with soil sampling and sample reduction for chemical analysis were quantified using laboratory-scale experiments and the theory of sampling. The research results showed that the TPH mass assessed by sampling tends to be overestimated and sampling errors are high, especially for the low range of TPH concentrations. Homogenization of soil was found to be an efficient method to suppress uncertainty, but high-resolution sampling could be an essential way to minimize this.

  16. Hydrogeochemical and stream sediment reconnaissance basic data for Cheyenne Quadrangle, Wyoming

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-07-31

    Field and laboratory data are presented for 884 water samples and 598 sediment samples from the Cheyenne Quadrangle, Wyoming. Uranium values have been reported by Los Alamos National Laboratory in Report GJBX-106(78). The samples were collected by Los Alamos National Laboratory; laboratory analysis and data reporting were performed by the Uranium Resource Evaluation Project at Oak Ridge, Tennessee.

  17. Field assisted sintering of refractory carbide ceramics and fiber reinforced ceramic matrix composites

    NASA Astrophysics Data System (ADS)

    Gephart, Sean

    The sintering behaviors of silicon carbide (SiC) and boron carbide (B4C) based materials were investigated using an emerging sintering technology known as field assisted sintering technology (FAST), also known as spark plasma sintering (SPS) and pulse electric current sintering (PECS). Sintering by FAST utilizes high density electric current, uniaxial pressure, and relatively high heating rate compared to conventional sintering techniques. This effort investigated issues of scaling from laboratory FAST system (25 ton capacity) to industrial FAST system (250 ton capacity), as well as exploring the difference in sintering behavior of single phase B4C and SiC using FAST and conventional sintering techniques including hot-pressing (HP) and pressure-less sintering (PL). Materials were analyzed for mechanical and bulk properties, including characterization of density, hardness, fracture toughness, fracture (bend) strength, elastic modulus and microstructure. A parallel investigation was conducted in the development of ceramic matrix composites (CMC) using SiC powder impregnation of fiber compacts followed by FAST sintering. The FAST technique was used to sinter several B4C and SiC materials to near theoretical density. Preliminary efforts established optimized sintering temperatures using the smaller 25 ton laboratory unit, targeting a sample size of 40 mm diameter and 8 mm thickness. Then the same B4C and SiC materials were sintered by the larger 250 ton industrial FAST system, a HP system, and PL sintering system with a targeted dense material geometry of 4 x 4 x 0.315 inches3 (101.6 x 101.6 x 8 mm3). The resulting samples were studied to determine if the sintering dynamics and/or the resulting material properties were influenced by the sintering technique employed. This study determined that FAST sintered ceramic materials resulted in consistently higher averaged values for mechanical properties as well as smaller grain size when compared to conventionally sintered materials. While FAST sintered materials showed higher average values, in general they also showed consistently larger variation in the scattered data and consequently larger standard deviation for the resulting material properties. In addition, dynamic impact testing (V50 test) was conducted on the resulting materials and it was determined that there was no discernable correlation between observed mechanical properties of the ceramic materials and the resulting dynamic testing. Another study was conducted on the sintering of SiC and carbon fiber reinforced SiC ceramic matrix composites (CMC) using FAST. There has been much interest recently in fabricating high strength, low porosity SiC CMC.s for high temperature structural applications, but the current methods of production, namely chemical vapor infiltration (CVI), melt infiltration (MI), and polymer infiltration and pyrolysis (PIP), are considered time consuming and involve material related shortcomings associated with their respective methodologies. In this study, SiC CMC.s were produced using the 25 ton laboratory unit with a target sample size of 40 mm diameter and 3 mm thickness, as well as on the larger 250 ton industrial FAST system targeting a sample size of 101.6 x 101.6 x 3 mm3 to investigate issues associated with scaling. Several sintering conditions were explored including: pressure of 35-65 MPa, temperature of 1700-1900°C, and heating rates between 50-400°C/min. The SiC fibers used in this study were coated using chemical vapor deposition (CVD) with boron nitride (BN) and pyrolytic carbon to act as a barrier layer and preserve the integrity of the fibers during sintering. Then the barrier coating was coated by an outer layer of SiC to enhance the bonding between the fibers and the SiC matrix. Microstructures of the sintered samples were examined by FE-SEM. Mechanical properties including flexural strength-deflection and stress-strain were characterized using 4-point bend testing. Tensile testing was performed on the larger 101.6 x 101.6 x 3 mm samples. The microstructures of samples sintered using the 25 ton laboratory FAST system showed a reduction in porosity and good adhesion between the fiber-fiber and fiber-matrix interface. The microstructures of samples sintered on the 250 ton industrial FAST system showed a reduction in porosity, but there was visible reaction of the fiber and fiber coatings with the surrounding matrix. Additionally, there was significant radial cracking of the fibers visible in the microstructures. There is gap in the understanding of sintering behavior between laboratory and industrial scale FAST systems. The vast majority of publications on FAST sintering have been primarily focused on small sample geometries (20 mm diameter, less than 3 mm thick). A study was coordinated to investigate the thermal properties during heating and cooling using a 250 ton industrial FAST system at 900°C using B4C and SiC materials inside the graphite die assembly. The thermal properties were then compared to the resulting material properties of the identically sintered B4C and SiC to approximately 94% relative density, at a temperature of 1950°C, pressure of 45 MPa, 10 minute hold, and heated at a rate of 100°C/min. The study determined that at 900°C there were significant thermal gradients within the system for the examined materials, and that these gradients correlated well with the material property difference of the samples sintered at higher temperatures where the gradients are presumably larger due to an increase in radiative heat loss. The observed temperatures throughout the graphite were significantly different between B4C and SiC. These temperatures also correlated well with the material properties of the sintered products which showed more substantial variation for B4C when compared to SiC which was overall less affected by thermal gradients. This was attributed to the intrinsic thermal conductivity difference between the two subject materials which was manifested as thermal gradients throughout the material and graphite die assembly. Additionally, both the observed temperature gradients throughout the graphite die assembly and the difference in temperature reading between the optical pyrometer and thermocouples were significantly larger for the 250 ton FAST system than previous publications have demonstrated experimentally or via modeling of smaller laboratory scale systems. The findings from this work showed that relative to conventional sintering methods, the FAST process demonstrated comparable or improved material and mechanical properties with a significantly shorter processing cycle. However, the results demonstrated on the 25 ton laboratory scale unit were significantly different compared to results for the same materials sintered using the 250 ton industrial scale unit. The temperature gradients observed on the 250 ton FAST unit were significantly larger than previous reports on smaller FAST units. This result showed future efforts to scale up the FAST sintering process while maintaining similar results will require careful attention to minimizing temperature gradients. This could potentially be achieved by reducing radiative heat loss during processing and/or optimizing the graphite die design and implementing heat spreaders in specific locations dependent on the host material.s thermal and electrical properties as well as the sample geometry.

  18. Epistemology and expectations survey about experimental physics: Development and initial results

    NASA Astrophysics Data System (ADS)

    Zwickl, Benjamin M.; Hirokawa, Takako; Finkelstein, Noah; Lewandowski, H. J.

    2014-06-01

    In response to national calls to better align physics laboratory courses with the way physicists engage in research, we have developed an epistemology and expectations survey to assess how students perceive the nature of physics experiments in the contexts of laboratory courses and the professional research laboratory. The Colorado Learning Attitudes about Science Survey for Experimental Physics (E-CLASS) evaluates students' epistemology at the beginning and end of a semester. Students respond to paired questions about how they personally perceive doing experiments in laboratory courses and how they perceive an experimental physicist might respond regarding their research. Also, at the end of the semester, the E-CLASS assesses a third dimension of laboratory instruction, students' reflections on their course's expectations for earning a good grade. By basing survey statements on widely embraced learning goals and common critiques of teaching labs, the E-CLASS serves as an assessment tool for lab courses across the undergraduate curriculum and as a tool for physics education research. We present the development, evidence of validation, and initial formative assessment results from a sample that includes 45 classes at 20 institutions. We also discuss feedback from instructors and reflect on the challenges of large-scale online administration and distribution of results.

  19. Test Plan for Methanotrophic Bioreactor at Savannah River Site-TNX

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berry, C.J.

    1994-10-04

    The primary purpose of this project is to demonstrate the feasibility and practicality of operating a methanotrophic mobile trickle filter bioreactor (MMB) unit to effectively reduce or eliminate trichloroethylene (TCE) and associated hydrocarbons from contaminated groundwater. The two-column trickle filter system can process 1.67 gallons per minute (gpm) of contaminated groundwater. During this project, the pilot system will evaluate, optimize, and demonstrate methanotrophic treatment technology (MTT). The mobile system will receive a 1--4% methane to air mixture for stimulating the methanotrophic TCE degrading bacteria, thereby increasing the rates of degradation of these contaminants. This project will also evaluate the efficacymore » of different bacteria for degrading TCE for use in the system at the laboratory-scale sample groundwater monitoring wells at TNX and set up the system for continued operation. The trickle filter system may be used to inexpensively treat other small-scale organic waste streams at SRS after the initial start-up. The MTT was demonstrated as an effective and efficient method of degrading TCE in the laboratory and during a field-scale in situ demonstration for degrading TCE in a groundwater plume at SRS. The methanotrophic bacteria increase significantly in population numbers and in the production of methane monooxygenase (MMO), an extremely powerful oxidizer. MMO was demonstrated as effective in oxidizing TCE and other recalcitrant compounds in laboratory studies. In the presence of MMO, TCE is oxidized to TCE-epoxide, which breaks down spontaneously into simple, easily degraded, daughter compounds. The system will receive a 1--4% methane to air mixture, which will effectively grow and maintain the methanotrophic bacteria that will degrade TCE. This demonstration will have broad applications to bioremediating contaminated groundwater systems where in situ bioremediation is not practical.« less

  20. The role of inter-comparisons in radiocarbon quality assurance

    NASA Astrophysics Data System (ADS)

    Scott, Marian; Cook, Gordon; Naysmith, Philip

    2016-04-01

    Radiocarbon dating is used widely in many geochronology projects as a basis for the creation and testing of chronological constructs. Radiocarbon measurements are by their nature complex and the degree of sample pre-treatment varies considerably depending on the material. Within the UK and Europe, there are a number of well-established laboratories and increasingly, scientists are not just commissioning new dates, but also using statistical modelling of assemblages of dates, perhaps measured in different laboratories, to provide formal date estimates for their investigations. The issue of comparability of measurements (and thus bias, accuracy and precision of measurement) from the diverse laboratories is one which has been the focus of some attention both within the 14C community and the wider user communities for some time. As a result of this but also as part of laboratory benchmarking and quality assurance, the 14C community has undertaken a wide-scale, far-reaching and evolving programme of inter-comparisons, to the benefit of laboratories and users alike. This paper presents the results from the most recent exercise SIRI. The objectives of SIRI included, through choice of material, to contribute to the discussion concerning laboratory offsets and error multipliers in the context of IntCal (the International Calibration Programme) and to gain a better understanding of differences in background derived from a range of infinite age material types.

  1. A microfluidic thermometer: Precise temperature measurements in microliter- and nanoliter-scale volumes

    PubMed Central

    McKenzie, Brittney A.

    2017-01-01

    Measuring the temperature of a sample is a fundamental need in many biological and chemical processes. When the volume of the sample is on the microliter or nanoliter scale (e.g., cells, microorganisms, precious samples, or samples in microfluidic devices), accurate measurement of the sample temperature becomes challenging. In this work, we demonstrate a technique for accurately determining the temperature of microliter volumes using a simple 3D-printed microfluidic chip. We accomplish this by first filling “microfluidic thermometer” channels on the chip with substances with precisely known freezing/melting points. We then use a thermoelectric cooler to create a stable and linear temperature gradient along these channels within a measurement region on the chip. A custom software tool (available as online Supporting Information) is then used to find the locations of solid-liquid interfaces in the thermometer channels; these locations have known temperatures equal to the freezing/melting points of the substances in the channels. The software then uses the locations of these interfaces to calculate the temperature at any desired point within the measurement region. Using this approach, the temperature of any microliter-scale on-chip sample can be measured with an uncertainty of about a quarter of a degree Celsius. As a proof-of-concept, we use this technique to measure the unknown freezing point of a 50 microliter volume of solution and demonstrate its feasibility on a 400 nanoliter sample. Additionally, this technique can be used to measure the temperature of any on-chip sample, not just near-zero-Celsius freezing points. We demonstrate this by using an oil that solidifies near room temperature (coconut oil) in a microfluidic thermometer to measure on-chip temperatures well above zero Celsius. By providing a low-cost and simple way to accurately measure temperatures in small volumes, this technique should find applications in both research and educational laboratories. PMID:29284028

  2. The economics of biobanking and pharmacogenetics databasing: the case of an adaptive platform on breast cancer.

    PubMed

    Huttin, Christine C; Liebman, Michael N

    2013-01-01

    This paper aims to discuss the economics of biobanking. Among the critical issues in evaluating potential ROI for creation of a bio-bank are: scale (e.g. local, national, international), centralized versus virtual/distributed, degree of sample annotation/QC procedures, targeted end-users and uses, types of samples, potential characterization, both of samples and annotations. The paper presents a review on cost models for an economic analysis of biobanking for different steps: data collection (e.g. biospecimens in different types of sites, storage, transport and distribution, information management for the different types of information (e.g. biological information such as cell, gene, and protein)). It also provides additional concepts to process biospecimens from laboratory to clinical practice and will help to identify how changing paradigms in translational medicine affect the economic modeling.

  3. Characterization Of The As-Received Sludge Batch 9 Qualification Sample (Htf-51-15-81)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pareizs, J.

    Savannah River National Laboratory (SRNL) personnel have been requested to qualify the next sludge batch (Sludge Batch 9 – SB9) for processing at the Defense Waste Processing Facility (DWPF). To accomplish this task, Savannah River Remediation (SRR) has sent SRNL a 3-L slurried sample of Tank 51H (HTF-51-15-81) to be characterized, washed, and then used in a lab-scale demonstration of the DWPF flowsheet (potentially after combining with Tank 40H sludge). This report documents the first steps of the qualification process – characterization of the as-received Tank 51H qualification sample. These results will be used to support a reprojection of SB9more » by SRR from which final Tank 51H washing, frit development, and Chemical Processing Cell (CPC) activities will be based.« less

  4. Performance audits and laboratory comparisons for SCOS97-NARSTO measurements of speciated volatile organic compounds

    NASA Astrophysics Data System (ADS)

    Fujita, Eric M.; Harshfield, Gregory; Sheetz, Laurence

    Performance audits and laboratory comparisons were conducted as part of the quality assurance program for the 1997 Southern California Ozone Study (SCOS97-NARSTO) to document potential measurement biases among laboratories measuring speciated nonmethane hydrocarbons (NMHC), carbonyl compounds, halogenated compounds, and biogenic hydrocarbons. The results show that measurements of volatile organic compounds (VOC) made during SCOS97-NARSTO are generally consistent with specified data quality objectives. The hydrocarbon comparison involved nine laboratories and consisted of two sets of collocated ambient samples. The coefficients of variation among laboratories for the sum of the 55 PAM target compounds and total NMHC ranged from ±5 to 15 percent for ambient samples from Los Angeles and Azusa. Abundant hydrocarbons are consistently identified by all laboratories, but discrepancies occur for olefins greater than C 4 and for hydrocarbons greater than C 8. Laboratory comparisons for halogenated compounds and biogenic hydrocarbons consisted of both concurrent ambient sampling by different laboratories and round-robin analysis of ambient samples. The coefficients of variation among participating laboratories were about 10-20 percent. Performance audits were conducted for measurement of carbonyl compounds involving sampling from a standard mixture of carbonyl compounds. The values reported by most of the laboratories were within 10-20 percent of those of the reference laboratory. Results of field measurement comparisons showed larger variations among the laboratories ranging from 20 to 40 percent for C 1-C 3 carbonyl compounds. The greater variations observed in the field measurement comparison may reflect potential sampling artifacts, which the performance audits did not address.

  5. Experimental methods for the simulation of supercritical CO2 injection at laboratory scale aimed to investigate capillary trapping

    NASA Astrophysics Data System (ADS)

    Trevisan, L.; Illangasekare, T. H.; Rodriguez, D.; Sakaki, T.; Cihan, A.; Birkholzer, J. T.; Zhou, Q.

    2011-12-01

    Geological storage of carbon dioxide in deep geologic formations is being considered as a technical option to reduce greenhouse gas loading to the atmosphere. The processes associated with the movement and stable trapping are complex in deep naturally heterogeneous formations. Three primary mechanisms contribute to trapping; capillary entrapment due to immobilization of the supercritical fluid CO2 within soil pores, liquid CO2 dissolving in the formation water and mineralization. Natural heterogeneity in the formation is expected to affect all three mechanisms. A research project is in progress with the primary goal to improve our understanding of capillary and dissolution trapping during injection and post-injection process, focusing on formation heterogeneity. It is expected that this improved knowledge will help to develop site characterization methods targeting on obtaining the most critical parameters that capture the heterogeneity to design strategies and schemes to maximize trapping. This research combines experiments at the laboratory scale with multiphase modeling to upscale relevant trapping processes to the field scale. This paper presents the results from a set of experiments that were conducted in an intermediate scale test tanks. Intermediate scale testing provides an attractive alternative to investigate these processes under controlled conditions in the laboratory. Conducting these types of experiments is highly challenging as methods have to be developed to extrapolate the data from experiments that are conducted under ambient laboratory conditions to high temperatures and pressures settings in deep geologic formations. We explored the use of a combination of surrogate fluids that have similar density, viscosity contrasts and analogous solubility and interfacial tension as supercritical CO2-brine in deep formations. The extrapolation approach involves the use of dimensionless numbers such as Capillary number (Ca) and the Bond number (Bo). A set of experiments that captures some of the complexities of the geologic heterogeneity and injection scenarios are planned in a 4.8 m long tank. To test the experimental methods and instrumentation, a set of preliminary experiments were conducted in a smaller tank with dimensions 90 cm x 60 cm. The tank was packed to represent both homogeneous and heterogeneous conditions. Using the surrogate fluids, different injection scenarios were tested. Images of the migration plume showed the critical role that heterogeneity plays in stable entrapment. Destructive sampling done at the end of the experiments provided data on the final saturation distributions. Preliminary analysis suggests the entrapment configuration is controlled by the large-scale heterogeneities as well as the pore-scale entrapment mechanisms. The data was used in modeling analysis that is presented in a companion abstract.

  6. Environmental Health and Safety Hazards of Indigenous Small-Scale Gold Mining Using Cyanidation in the Philippines

    PubMed Central

    Leung, Ana Marie R.; Lu, Jinky Leilanie DP.

    2016-01-01

    OBJECTIVES This cross-sectional study aimed at the environmental health hazards at work and cyanide exposure of small-scale gold miners engaged in gold extraction from ores in a mining area in the Philippines. METHODS Methods consisted of structured questionnaire-guided interviews, work process observation tools, physical health assessment by medical doctors, and laboratory examination and blood cyanide determination in the blood samples of 34 indigenous small-scale gold miners from Benguet, Philippines. RESULTS The small-scale gold miners worked for a mean of 10.3 years, had a mean age of 36 years, with mean lifetime mining work hours of 18,564. All were involved in tunneling work (100%) while a considerable number were involved in mixing cyanide with the ore (44%). A considerable number were injured (35%) during the mining activity, and an alarming number (35%) had elevated blood cyanide level. The most prevalent hazard was exposure to chemicals, particularly to cyanide and nitric acid, which were usually handled with bare hands. CONCLUSION The small-scale gold miners were exposed to occupational and environmental hazards at work. PMID:27547035

  7. Environmental Health and Safety Hazards of Indigenous Small-Scale Gold Mining Using Cyanidation in the Philippines.

    PubMed

    Leung, Ana Marie R; Lu, Jinky Leilanie Dp

    2016-01-01

    This cross-sectional study aimed at the environmental health hazards at work and cyanide exposure of small-scale gold miners engaged in gold extraction from ores in a mining area in the Philippines. Methods consisted of structured questionnaire-guided interviews, work process observation tools, physical health assessment by medical doctors, and laboratory examination and blood cyanide determination in the blood samples of 34 indigenous small-scale gold miners from Benguet, Philippines. The small-scale gold miners worked for a mean of 10.3 years, had a mean age of 36 years, with mean lifetime mining work hours of 18,564. All were involved in tunneling work (100%) while a considerable number were involved in mixing cyanide with the ore (44%). A considerable number were injured (35%) during the mining activity, and an alarming number (35%) had elevated blood cyanide level. The most prevalent hazard was exposure to chemicals, particularly to cyanide and nitric acid, which were usually handled with bare hands. The small-scale gold miners were exposed to occupational and environmental hazards at work.

  8. Teaching evidence-based practice: developing a curriculum model to foster evidence-based practice in undergraduate student nurses.

    PubMed

    Finotto, Stefano; Carpanoni, Marika; Turroni, Elena Casadei; Camellini, Riccarda; Mecugni, Daniela

    2013-09-01

    For the nature of the Evidence-Based Practice (EBP) and its relevance to nursing, the skills that it requires should be a component in the basic Nursing degree courses. For this reason, the EBP process should be introduced early on in nursing education to develop students' independence and ability to self-learning. the aim of this study is to describe the perception that newly graduated nurses have relative to the benefits of the skills learned during the laboratory's three-year EBP in consideration of the construction of the thesis, the research of evidence and usefulness of the EBP process for the development of their professional career. A descriptive study with a sample of 300 newly graduated nurses from the Degree Course in Nursing of the University of Modena and Reggio Emilia, venue of Reggio Emilia. The data collection instrument was an anonymous questionnaire. It was possible to answer through a 10 Likert scale. The sample considers effective the research of evidence carried out (mean 6, SD 2), related to the problems of patients (mean 7, SD 2); the sample considered the skills acquired during the laboratory's three-year EBP to be useful for career development (mean 7, SD 2). the decision to include the laboratory's three-year EBP in the curriculum of the Nursing degree promotes the development of skills relating to the use of the EBP process, competence that in the literature is indicated as one of the core competencies that all health professionals should develop and maintain throughout their professional career. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Enabling UAS Research at the NASA EAV Laboratory

    NASA Technical Reports Server (NTRS)

    Ippolito, Corey A.

    2015-01-01

    The Exploration Aerial Vehicles (EAV) Laboratory at NASA Ames Research Center leads research into intelligent autonomy and advanced control systems, bridging the gap between simulation and full-scale technology through flight test experimentation on unmanned sub-scale test vehicles.

  10. TREATMENT OF INORGANIC CONTAMINANTS USING PERMEABLE REACTIVE BARRIERS

    EPA Science Inventory

    Permeable reactive barriers are an emerging alternative to traditional pump and treat systems for groundwater remediation. This technique has progressed rapidly over the past decade from laboratory bench-scale studies to full-scale implementation. Laboratory studies indicate the ...

  11. Tinea Capitis: Mixed or Consecutive Infection with White and Violet Strains of Trichophyton violaceum: A Diagnostic or Therapeutic Challenge

    PubMed Central

    Goyal, Roma

    2015-01-01

    Tinea capitis is a common dermatophyte infection affecting scalp and hair of pre-pubertal children. With introduction of Griseofulvin in 1958, there has been considerable improvement in the treatment of tinea capitis. A seven-year-old male child was brought to the dermatology clinic. He presented with diffuse white scaly patches of alopecia on scalp of one-year duration. The child was sent to the microbiology section of the National Health laboratory, Botswana for the collection of the samples. The samples consisted of scalp scrapings and few plucked hairs from the suspicious areas, which were collected by swab and scalpel blade methods. Potassium hydroxide (10% KOH) mounts were prepared for scales and hair samples. Scales were positive for fungal elements and endothrix type of perforation was seen in hair. Cultures on Sabouraud’s dextrose agar (SDA) and Derm agar were incubated at 25°C, which yielded white variant of Trichophyton violaceum after two weeks of incubation. T. vioaceum (white variant) grew in all the plates. After six weeks of treatment with griseofulvin, the repeat culture grew only T. violaceum (violet strain). The child showed a definite clinical improvement. PMID:26814801

  12. Validation of a Thermo-Ablative Model of Elastomeric Internal Insulation Materials

    NASA Technical Reports Server (NTRS)

    Martin, Heath T.

    2017-01-01

    In thermo-ablative material modeling, as in many fields of analysis, the quality of the existing models significantly exceeds that of the experimental data required for their validation. In an effort to narrow this gap, a laboratory-scale internal insulation test bed was developed that exposes insulation samples to realistic solid rocket motor (SRM) internal environments while being instrumented to record real-time rates of both model inputs (i.e., chamber pressure, total surface heat flux, and radiative heat flux) as well as model outputs (i.e., material decomposition depths (MDDs) and in-depth material temperatures). In this work, the measured SRM internal environment parameters were used in conjunction with equilibrium thermochemistry codes as inputs to one-dimensional thermo-ablative models of the PBINBR and CFEPDM insulation samples used in the lab-scale test firings. The computed MDD histories were then compared with those deduced from real-time X-ray radiography of the insulation samples, and the calculated in-depth temperatures were compared with those measured by embedded thermocouples. The results of this exercise emphasize the challenges of modeling and testing elastomeric materials in SRM environments while illuminating the path forward to improved fidelity.

  13. Factors that impact clinical laboratory scientists' commitment to their work organizations.

    PubMed

    Bamberg, Richard; Akroyd, Duane; Moore, Ti'eshia M

    2008-01-01

    To assess the predictive ability of various aspects of the work environment for organizational commitment. A questionnaire measuring three dimensions of organizational commitment along with five aspects of work environment and 10 demographic and work setting characteristics was sent to a national, convenience sample of clinical laboratory professionals. All persons obtaining the CLS certification by NCA from January 1, 1997 to December 31, 2006. Only respondents who worked full-time in a clinical laboratory setting were included in the database. Levels of affective, normative, and continuance organizational commitment, organizational support, role clarity, role conflict, transformational leadership behavior of supervisor, and organizational type, total years work experience in clinical laboratories, and educational level of respondents. Questionnaire items used either a 7-point or 5-point Likert response scale. Based on multiple regression analysis for the 427 respondents, organizational support and transformational leadership behavior were found to be significant positive predictors of affective and normative organizational commitment. Work setting (non-hospital laboratory) and total years of work experience in clinical laboratories were found to be significant positive predictors of continuance organizational commitment. Overall the organizational commitment levels for all three dimensions were at the neutral rating or below in the slightly disagree range. The results indicate a less than optimal level of organizational commitment to employers, which were predominantly hospitals, by CLS practitioners. This may result in continuing retention problems for hospital laboratories. The results offer strategies for improving organizational commitment via the significant predictors.

  14. Progress toward the determination of correct classification rates in fire debris analysis.

    PubMed

    Waddell, Erin E; Song, Emma T; Rinke, Caitlin N; Williams, Mary R; Sigman, Michael E

    2013-07-01

    Principal components analysis (PCA), linear discriminant analysis (LDA), and quadratic discriminant analysis (QDA) were used to develop a multistep classification procedure for determining the presence of ignitable liquid residue in fire debris and assigning any ignitable liquid residue present into the classes defined under the American Society for Testing and Materials (ASTM) E 1618-10 standard method. A multistep classification procedure was tested by cross-validation based on model data sets comprised of the time-averaged mass spectra (also referred to as total ion spectra) of commercial ignitable liquids and pyrolysis products from common building materials and household furnishings (referred to simply as substrates). Fire debris samples from laboratory-scale and field test burns were also used to test the model. The optimal model's true-positive rate was 81.3% for cross-validation samples and 70.9% for fire debris samples. The false-positive rate was 9.9% for cross-validation samples and 8.9% for fire debris samples. © 2013 American Academy of Forensic Sciences.

  15. Neutron-Irradiated Samples as Test Materials for MPEX

    DOE PAGES

    Ellis, Ronald James; Rapp, Juergen

    2015-10-09

    Plasma Material Interaction (PMI) is a major concern in fusion reactor design and analysis. The Material-Plasma Exposure eXperiment (MPEX) will explore PMI under fusion reactor plasma conditions. Samples with accumulated displacements per atom (DPA) damage produced by fast neutron irradiations in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) will be studied in the MPEX facility. This paper presents assessments of the calculated induced radioactivity and resulting radiation dose rates of a variety of potential fusion reactor plasma-facing materials (such as tungsten). The scientific code packages MCNP and SCALE were used to simulate irradiation of themore » samples in HFIR including the generation and depletion of nuclides in the material and the subsequent composition, activity levels, gamma radiation fields, and resultant dose rates as a function of cooling time. A challenge of the MPEX project is to minimize the radioactive inventory in the preparation of the samples and the sample dose rates for inclusion in the MPEX facility.« less

  16. Quality-assurance plan for the analysis of fluvial sediment by the U.S. Geological Survey Kentucky Water Science Center Sediment Laboratory

    USGS Publications Warehouse

    Shreve, Elizabeth A.; Downs, Aimee C.

    2005-01-01

    This report describes laboratory procedures used by the U.S. Geological Survey Kentucky Water Science Center Sediment Laboratory for the processing and analysis of fluvial-sediment samples for concentration of sand and finer material. The report details the processing of a sediment sample through the laboratory from receiving the sediment sample, through the analytical process, to compiling results of the requested analysis. Procedures for preserving sample integrity, calibrating and maintaining of laboratory and field instruments and equipment, analyzing samples, internal quality assurance and quality control, and validity of the sediment-analysis results also are described. The report includes a list of references cited and a glossary of sediment and quality-assurance terms.

  17. Hydrogeochemical and stream sediment reconnaissance basic data for Aztec Quadrangle, New Mexico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-07-31

    Field and laboratory data are presented for 331 water samples and 1693 sediment samples from the Aztec Quadrangle, New Mexico. Uranium values have been reported by Los Alamos National Laboratory in Report GJBX-129(78). The samples were collected by Los Alamos National Laboratory; laboratory analysis and data reporting were performed by the Uranium Resource Evaluation Project at Oak Ridge, Tennessee.

  18. Ecological aspects of pain in sensory modulation disorder.

    PubMed

    Bar-Shalita, T; Deutsch, L; Honigman, L; Weissman-Fogel, I

    2015-01-01

    Sensory Modulation Disorder (SMD) interferes with the daily life participation of otherwise healthy individuals and is characterized by over-, under- or seeking responsiveness to naturally occurring sensory stimuli. Previous laboratory findings indicate pain hyper-sensitivity in SMD individuals suggesting CNS alteration in pain processing and modulation. However, laboratory studies lack ecological validity, and warrant clinical completion in order to elicit a sound understanding of the phenomenon studied. Thus, this study explored the association between sensory modulation and pain in a daily life context in a general population sample. Daily life context of pain and sensations were measured in 250 adults (aged 23-40 years; 49.6% males) using 4 self-report questionnaires: Pain Sensitivity Questionnaire (PSQ) and Pain Catastrophizing Scale (PCS) to evaluate the sensory and cognitive aspects of pain; the Sensory Responsiveness Questionnaire (SRQ) to appraise SMD; and the Short Form - 36 Health Survey, version 2 (SF36) to assess health related Quality of Life (QoL). Thirty two individuals (12.8%) were found with over-responsiveness type of SMD, forming the SOR-SMD group. While no group differences (SOR-SMD vs. Non-SMD) were found, low-to-moderate total sample correlations were demonstrated between the SRQ-Aversive sub-scale and i) PSQ total (r=0.31, p<0.01) and sub-scales scores (r=0.27-0.28, p<0.01), as well as ii) PCS total and the sub-scales of Rumination and Helplessness scores (r=0.15, p<0.05). PSQ total and sub-scale scores were more highly correlated with SRQ-Aversive in the SOR-SMD group (r=0.57-0.68, p=0.03-<0.01) compared to Non-SMD group. The Physical Health - Total score (but not the Mental Health - Total) of the SF36 was lower for the SOR-SMD group (p=0.03), mainly due to the difference in the Body pain sub-scale (p=0.04). Results suggest that SOR-SMD is strongly associated with the sensory aspect of pain but weakly associated with the cognitive aspect. This indicates that SMD co-occurs with daily pain sensitivity, thus reducing QoL, but less with the cognitive-catastrophizing manifestation of pain perception. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Acoustic Treatment Design Scaling Methods. Volume 3; Test Plans, Hardware, Results, and Evaluation

    NASA Technical Reports Server (NTRS)

    Yu, J.; Kwan, H. W.; Echternach, D. K.; Kraft, R. E.; Syed, A. A.

    1999-01-01

    The ability to design, build, and test miniaturized acoustic treatment panels on scale-model fan rigs representative of the full-scale engine provides not only a cost-savings, but an opportunity to optimize the treatment by allowing tests of different designs. To be able to use scale model treatment as a full-scale design tool, it is necessary that the designer be able to reliably translate the scale model design and performance to an equivalent full-scale design. The primary objective of the study presented in this volume of the final report was to conduct laboratory tests to evaluate liner acoustic properties and validate advanced treatment impedance models. These laboratory tests include DC flow resistance measurements, normal incidence impedance measurements, DC flow and impedance measurements in the presence of grazing flow, and in-duct liner attenuation as well as modal measurements. Test panels were fabricated at three different scale factors (i.e., full-scale, half-scale, and one-fifth scale) to support laboratory acoustic testing. The panel configurations include single-degree-of-freedom (SDOF) perforated sandwich panels, SDOF linear (wire mesh) liners, and double-degree-of-freedom (DDOF) linear acoustic panels.

  20. Examining Radiation-Induced In Vivo and In Vitro Gene Expression Changes of the Peripheral Blood in Different Laboratories for Biodosimetry Purposes: First RENEB Gene Expression Study.

    PubMed

    Abend, M; Badie, C; Quintens, R; Kriehuber, R; Manning, G; Macaeva, E; Njima, M; Oskamp, D; Strunz, S; Moertl, S; Doucha-Senf, S; Dahlke, S; Menzel, J; Port, M

    2016-02-01

    The risk of a large-scale event leading to acute radiation exposure necessitates the development of high-throughput methods for providing rapid individual dose estimates. Our work addresses three goals, which align with the directive of the European Union's Realizing the European Network of Biodosimetry project (EU-RENB): 1. To examine the suitability of different gene expression platforms for biodosimetry purposes; 2. To perform this examination using blood samples collected from prostate cancer patients (in vivo) and from healthy donors (in vitro); and 3. To compare radiation-induced gene expression changes of the in vivo with in vitro blood samples. For the in vitro part of this study, EDTA-treated whole blood was irradiated immediately after venipuncture using single X-ray doses (1 Gy/min(-1) dose rate, 100 keV). Blood samples used to generate calibration curves as well as 10 coded (blinded) samples (0-4 Gy dose range) were incubated for 24 h in vitro, lysed and shipped on wet ice. For the in vivo part of the study PAXgene tubes were used and peripheral blood (2.5 ml) was collected from prostate cancer patients before and 24 h after the first fractionated 2 Gy dose of localized radiotherapy to the pelvis [linear accelerator (LINAC), 580 MU/min, exposure 1-1.5 min]. Assays were run in each laboratory according to locally established protocols using either microarray platforms (2 laboratories) or qRT-PCR (2 laboratories). Report times on dose estimates were documented. The mean absolute difference of estimated doses relative to the true doses (Gy) were calculated. Doses were also merged into binary categories reflecting aspects of clinical/diagnostic relevance. For the in vitro part of the study, the earliest report time on dose estimates was 7 h for qRT-PCR and 35 h for microarrays. Methodological variance of gene expression measurements (CV ≤10% for technical replicates) and interindividual variance (≤twofold for all genes) were low. Dose estimates based on one gene, ferredoxin reductase (FDXR), using qRT-PCR were as precise as dose estimates based on multiple genes using microarrays, but the precision decreased at doses ≥2 Gy. Binary dose categories comprising, for example, unexposed compared with exposed samples, could be completely discriminated with most of our methods. Exposed prostate cancer blood samples (n = 4) could be completely discriminated from unexposed blood samples (n = 4, P < 0.03, two-sided Fisher's exact test) without individual controls. This could be performed by introducing an in vitro-to-in vivo correction factor of FDXR, which varied among the laboratories. After that the in vitro-constructed calibration curves could be used for dose estimation of the in vivo exposed prostate cancer blood samples within an accuracy window of ±0.5 Gy in both contributing qRT-PCR laboratories. In conclusion, early and precise dose estimates can be performed, in particular at doses ≤2 Gy in vitro. Blood samples of prostate cancer patients exposed to 0.09-0.017 Gy could be completely discriminated from pre-exposure blood samples with the doses successfully estimated using adjusted in vitro-constructed calibration curves.

  1. Five years' experience of classical swine fever polymerase chain reaction ring trials in France.

    PubMed

    Po, F; Le Dimna, M; Le Potier, M F

    2011-12-01

    Since 2004, the French National Reference Laboratory for classical swine fever (CSF) has conducted an annual proficiency test (PT) to evaluate the ability of local veterinary laboratories to perform real-time polymerase chain reaction (PCR) for CSF virus. The results of five years of testing (2004-2008) are described here. The PT was conducted under blind conditions on 20 samples. The same batch of samples was used for all five years. The number of laboratories that analysed the samples increased from four in 2004 to 13 in 2008. The results of the PT showed the following: cross-contamination between samples and deficiencies in RNA preparation can occur even in experienced laboratories; sample homogeneity should be checked carefully before selection; samples stored at-80 degrees C for several years remain stable; and poor shipment conditions do not damage the samples with regard to detection of CSF virus genome. These results will enable redesign of the panel to improve the overall quality of the PT, which will encourage laboratories to check and improve their PCR procedures and expertise. This is an excellent way to determine laboratory performance.

  2. Suitability of chondrules for studying the magnetic field of the early solar system: an examination of synthetically produced dusty olivine

    NASA Astrophysics Data System (ADS)

    Hu, Y.; Feinberg, J. M.; Church, N.; Bromiley, G.; Bowles, J.; Jackson, M.; Moskowitz, B. M.; Harrison, R. J.

    2008-12-01

    Chondritic meteorites are rare, yet incredibly valuable windows into the geophysical and geochemical environment of the early solar system. Dusty olivine grains containing exsolved nanometer-scale iron-nickel alloy inclusions are present in many chondritic meteorites and their remanent magnetization may give insight into the strength of the solar dynamo at the time of chondrule formation. Laboratory methods for determining the paleointensity of these rare materials must be optimized prior to conducting experiments on actual meteorite samples. To this end, we have used high temperature recrystallization techniques to produce synthetic dusty olivine samples with textures remarkably similar to those observed in chondritic meteorites. The olivine grains used in these annealing experiments are from the 13 kya Haleyjabunga picritic basalt flow in Iceland and have compositions of Fo90, which closely resembles the olivine composition observed in chondritic meteorites. Samples were annealed at 1350°C either under vacuum in the presence of graphite or under controlled oxygen fugacity using pure CO gas. The laboratory-produced magnetic mineral assemblages in two sets of samples have been characterized using low and high temperature remanence and susceptibility measurements, hysteresis loops, FORC diagrams, and scanning electron microscopy. The room-temperature remanence properties of these materials have been explored using stepwise IRM and ARM acquisition and alternating field demagnetization. These synthesis techniques allow us to produce a wide rage of iron-nickel grain sizes with correspondingly large variations in coercivity (between 0 and 500 mT). High temperature measurements of saturation magnetization show that both samples reach their Curie temperatures at ~760°C, consistent with kamacite, a low-Ni high-Fe metal alloy. Multiple experiments have shown that care must be taken to rigorously control the atmosphere in which the samples are heated and cooled in order to avoid forming trace amounts of magnetite on the surface of the samples. Future research will explore the feasibility of using modified Thellier protocols to determine the paleointensity of laboratory-induced thermoremanent magnetizations.

  3. Development of a Low-Level Ar-37 Calibration Standard

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, Richard M.; Aalseth, Craig E.; Bowyer, Ted W.

    Argon-37 is an important environmental signature of an underground nuclear explosion. Producing and quantifying low-level 37Ar standards is an important step in the development of sensitive field measurement instruments for use during an On-Site Inspection, a key provision of the Comprehensive Nuclear-Test-Ban Treaty. This paper describes progress at Pacific Northwest National Laboratory (PNNL) in the development of a process to generate and quantify low-level 37Ar standard material, which can then be used to calibrate sensitive field systems at activities consistent with soil background levels. The 37Ar used for our work was generated using a laboratory-scale, high-energy neutron source to irradiatemore » powdered samples of calcium carbonate. Small aliquots of 37Ar were then extracted from the head space of the irradiated samples. The specific activity of the head space samples, mixed with P10 (90% stable argon:10% methane by mole fraction) count gas, is then derived using the accepted Length-Compensated Internal-Source Proportional Counting method. Due to the low activity of the samples, a set of three Ultra-Low Background Proportional-Counters designed and fabricated at PNNL from radio-pure electroformed copper was used to make the measurements in PNNL’s shallow underground counting laboratory. Very low background levels (<10 counts/day) have been observed in the spectral region near the 37Ar emission feature at 2.8 keV. Two separate samples from the same irradiation were measured. The first sample was counted for 12 days beginning 28 days after irradiation, the second sample was counted for 24 days beginning 70 days after irradiation (the half-life of 37Ar is 35.0 days). Both sets of measurements were analyzed and yielded very similar results for the starting activity (~0.1 Bq) and activity concentration (0.15 mBq/ccSTP argon) after P10 count gas was added. A detailed uncertainty model was developed based on the ISO Guide to the Expression of Uncertainty in Measurement. This paper presents a discussion of the measurement analysis, along with assumptions and uncertainty estimates.« less

  4. Nursing students' experiences of and satisfaction with the clinical learning environment: the role of educational models in the simulation laboratory and in clinical practice.

    PubMed

    Cremonini, Valeria; Ferri, Paola; Artioli, Giovanna; Sarli, Leopoldo; Piccioni, Enrico; Rubbi, Ivan

    2015-01-01

    Student satisfaction is an important element of the effectiveness of clinical placement, but there is little consensus in the literature as to the preferred model of clinical experience for undergraduate nursing students. The aim of this study was assess, for each academic year, students' perception of the roles of nurse teachers (NT) and clinical nurse supervisors (CNS) who perform tutoring in both apprenticeship and laboratories and to identify and evaluate students' satisfaction with the environment of clinical learning. This analytic cross-sectional study was conducted in a sample of 173 nursing students in the Northern Italy. The research instrument used is the Clinical learning environment, supervision and nurse teacher (CLES+T) evaluation scale. Data were statistically analysed. 94% of our sample answered questionnaires. Students expressed a higher level of satisfaction with their training experiences. The highest mean value was in the sub-dimension "Pedagogical atmosphere on the ward". Third year students expressed higher satisfaction levels in their relationship with the CNS and lower satisfaction levels in their relationship with the NT. This result may be due to the educational model that is adopted in the course, in which the simulation laboratory didactic activities of the third year are conducted by CNS, who also supervises experiences of clinical learning in the clinical practice. The main finding in this study was that the students' satisfaction with the supervisory relationship and the role of NT depend on how supervision in the clinical practice and in the simulation laboratory is organized.

  5. PDC-bit performance under simulated borehole conditions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, E.E.; Azar, J.J.

    1993-09-01

    Laboratory drilling tests were used to investigate the effects of pressure on polycrystalline-diamond-compact (PDC) drill-bit performance. Catoosa shale core samples were drilled with PDC and roller-cone bits at up to 1,750-psi confining pressure. All tests were conducted in a controlled environment with a full-scale laboratory drilling system. Test results indicate, that under similar operating conditions, increases in confining pressure reduce PDC-bit performance as much as or more than conventional-rock-bit performance. Specific energy calculations indicate that a combination of rock strength, chip hold-down, and bit balling may have reduced performance. Quantifying the degree to which pressure reduces PDC-bit performance will helpmore » researchers interpret test results and improve bit designs and will help drilling engineers run PDC bits more effectively in the field.« less

  6. The Influence of Alumina Properties on its Dissolution in Smelting Electrolyte

    NASA Astrophysics Data System (ADS)

    Bagshaw, A. N.; Welch, B. J.

    The dissolution of a wide range of commercially produced aluminas in modified cryolite bath was studied on a laboratory scale. Most of the aluminas were products of conventional refineries and smelter dry scrubbing systems; a few were produced in laboratory and pilot calciners, enabling greater flexibility in the calcination process and the final properties. The mode of alumina feeding and the size of addition approximated to the point feeder situation. Alpha-alumina content, B.E.T. surface area and median particle size had little impact on dissolution behaviour. The volatiles content, expressed as L.O.I., the morphology of the original hydrate and the mode of calcination had the most influence. Discrete intermediate oxide phases were identified in all samples; delta-alumina content impacted most on dissolution. The flow properties of an alumina affected its overall dissolution.

  7. A Study of Concept Mapping as an Instructional Intervention in an Undergraduate General Chemistry Calorimetry Laboratory

    NASA Astrophysics Data System (ADS)

    Stroud, Mary W.

    This investigation, rooted in both chemistry and education, considers outcomes occurring in a small-scale study in which concept mapping was used as an instructional intervention in an undergraduate calorimetry laboratory. A quasi-experimental, multiple-methods approach was employed since the research questions posed in this study warranted the use of both qualitative and quantitative perspectives and evaluations. For the intervention group of students, a convenience sample, post-lab concept maps, written discussions, quiz responses and learning surveys were characterized and evaluated. Archived quiz responses for non-intervention students were also analyzed for comparison. Students uniquely constructed individual concept maps containing incorrect, conceptually correct and "scientifically thin" calorimetry characterizations. Students more greatly emphasized mathematical relationships and equations utilized during the calorimetry experiment; the meaning of calorimetry concepts was demonstrated to a lesser extent.

  8. Continuous Severe Plastic Deformation Processing of Aluminum Alloys

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raghavan Srinivasan; Prabir K. Chaudhury; Balakrishna Cherukuri

    2006-06-30

    Metals with grain sizes smaller than 1-micrometer have received much attention in the past decade. These materials have been classified as ultra fine grain (UFG) materials (grain sizes in the range of 100 to 1000-nm) and nano-materials (grain size <100-nm) depending on the grain size. This report addresses the production of bulk UFG metals through the use of severe plastic deformation processing, and their subsequent use as stock material for further thermomechanical processing, such as forging. A number of severe plastic deformation (SPD) methods for producing bulk UFG metals have been developed since the early 1990s. The most promising ofmore » these processes for producing large size stock that is suitable for forging is the equal channel angular extrusion or pressing (ECAE/P) process. This process involves introducing large shear strain in the work-piece by pushing it through a die that consists of two channels with the same cross-sectional shape that meet at an angle to each other. Since the cross-sections of the two channels are the same, the extruded product can be re-inserted into the entrance channel and pushed again through the die. Repeated extrusion through the ECAE/P die accumulates sufficient strain to breakdown the microstructure and produce ultra fine grain size. It is well known that metals with very fine grain sizes (< 10-micrometer) have higher strain rate sensitivity and greater elongation to failure at elevated temperature, exhibiting superplastic behavior. However, this superplastic behavior is usually manifest at high temperature (> half the melting temperature on the absolute scale) and very low strain rates (< 0.0001/s). UFG metals have been shown to exhibit superplastic characteristics at lower temperature and higher strain rates, making this phenomenon more practical for manufacturing. This enables part unitization and forging more complex and net shape parts. Laboratory studies have shown that this is particularly true for UFG metals produced by SPD techniques. This combination of properties makes UFG metals produced by SPD very attractive as machining, forging or extrusion stock, both from the point of view of formability as well as energy and cost saving. However, prior to this work there had been no attempt to transfer these potential benefits observed in the laboratory scale to industrial shop floor. The primary reason for this was that the laboratory scale studies had been conducted to develop a scientific understanding of the processes that result in grain refinement during SPD. Samples that had been prepared in the laboratory scale were typically only about 10-mm diameter and 50-mm long (about 0.5-inch diameter and 2-inches long). The thrust of this project was three-fold: (i) to show that the ECAE/P process can be scaled up to produce long samples, i.e., a continuous severe plastic deformation (CSPD) process, (ii) show the process can be scaled up to produce large cross section samples that could be used as forging stock, and (iii) use the large cross-section samples to produce industrial size forgings and demonstrate the potential energy and cost savings that can be realized if SPD processed stock is adopted by the forging industry. Aluminum alloy AA-6061 was chosen to demonstrate the feasibility of the approach used. The CSPD process developed using the principles of chamber-less extrusion and drawing, and was demonstrated using rolling and wire drawing equipment that was available at Oak Ridge National Laboratory. In a parallel effort, ECAE/P dies were developed for producing 100-mm square cross section SPD billets for subsequent forging. This work was carried out at Intercontinental Manufacturing Co. (IMCO), Garland TX. Forging studies conducted with the ECAE/P billets showed that many of the potential benefits of using UFG material can be realized. In particular, the material yield can be increased, and the amount of material that is lost as scrap can be reduced by as much as 50%. Forging temperatures can also be reduced by over 150ºC, resulting in energy savings in the operation of billet heating furnaces. Looking at only the energy required to make forgings from stock materials, estimated energy savings associated with reduced scrap and lower furnace operating temperatures were greater than 40% if ECAE/P stock material was used instead of conventionally extruded stock. Subsequent heat treatment of the forged materials to the T6 condition showed that the mechanical properties of parts made from the ECAE/P stock material were the same as of those made from conventional extruded stock material. Therefore, the energy and cost savings benefits can be realized by the use SPD processed material as forging stock without sacrificing properties in the final part.« less

  9. Flow-induced vibration analysis of a helical coil steam generator experiment using large eddy simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yuan, Haomin; Solberg, Jerome; Merzari, Elia

    This paper describes a numerical study of flow-induced vibration in a helical coil steam generator experiment conducted at Argonne National Laboratory in the 1980s. In the experiment, a half-scale sector model of a steam generator helical coil tube bank was subjected to still and flowing air and water, and the vibrational characteristics were recorded. The research detailed in this document utilizes the multi-physics simulation toolkit SHARP developed at Argonne National Laboratory, in cooperation with Lawrence Livermore National Laboratory, to simulate the experiment. SHARP uses the spectral element code Nek5000 for fluid dynamics analysis and the finite element code DIABLO formore » structural analysis. The flow around the coil tubes is modeled in Nek5000 by using a large eddy simulation turbulence model. Transient pressure data on the tube surfaces is sampled and transferred to DIABLO for the structural simulation. The structural response is simulated in DIABLO via an implicit time-marching algorithm and a combination of continuum elements and structural shells. Tube vibration data (acceleration and frequency) are sampled and compared with the experimental data. Currently, only one-way coupling is used, which means that pressure loads from the fluid simulation are transferred to the structural simulation but the resulting structural displacements are not fed back to the fluid simulation« less

  10. Flow-induced vibration analysis of a helical coil steam generator experiment using large eddy simulation

    DOE PAGES

    Yuan, Haomin; Solberg, Jerome; Merzari, Elia; ...

    2017-08-01

    This study describes a numerical study of flow-induced vibration in a helical coil steam generator experiment conducted at Argonne National Laboratory in the 1980 s. In the experiment, a half-scale sector model of a steam generator helical coil tube bank was subjected to still and flowing air and water, and the vibrational characteristics were recorded. The research detailed in this document utilizes the multi-physics simulation toolkit SHARP developed at Argonne National Laboratory, in cooperation with Lawrence Livermore National Laboratory, to simulate the experiment. SHARP uses the spectral element code Nek5000 for fluid dynamics analysis and the finite element code DIABLOmore » for structural analysis. The flow around the coil tubes is modeled in Nek5000 by using a large eddy simulation turbulence model. Transient pressure data on the tube surfaces is sampled and transferred to DIABLO for the structural simulation. The structural response is simulated in DIABLO via an implicit time-marching algorithm and a combination of continuum elements and structural shells. Tube vibration data (acceleration and frequency) are sampled and compared with the experimental data. Currently, only one-way coupling is used, which means that pressure loads from the fluid simulation are transferred to the structural simulation but the resulting structural displacements are not fed back to the fluid simulation.« less

  11. Flow-induced vibration analysis of a helical coil steam generator experiment using large eddy simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yuan, Haomin; Solberg, Jerome; Merzari, Elia

    This study describes a numerical study of flow-induced vibration in a helical coil steam generator experiment conducted at Argonne National Laboratory in the 1980 s. In the experiment, a half-scale sector model of a steam generator helical coil tube bank was subjected to still and flowing air and water, and the vibrational characteristics were recorded. The research detailed in this document utilizes the multi-physics simulation toolkit SHARP developed at Argonne National Laboratory, in cooperation with Lawrence Livermore National Laboratory, to simulate the experiment. SHARP uses the spectral element code Nek5000 for fluid dynamics analysis and the finite element code DIABLOmore » for structural analysis. The flow around the coil tubes is modeled in Nek5000 by using a large eddy simulation turbulence model. Transient pressure data on the tube surfaces is sampled and transferred to DIABLO for the structural simulation. The structural response is simulated in DIABLO via an implicit time-marching algorithm and a combination of continuum elements and structural shells. Tube vibration data (acceleration and frequency) are sampled and compared with the experimental data. Currently, only one-way coupling is used, which means that pressure loads from the fluid simulation are transferred to the structural simulation but the resulting structural displacements are not fed back to the fluid simulation.« less

  12. FLARE: A New User Facility for Laboratory Studies of Multiple-Scale Physics of Magnetic Reconnection and Related Phenomena in Heliophysics and Astrophysics

    NASA Astrophysics Data System (ADS)

    Ji, H.; Bhattacharjee, A.; Goodman, A.; Prager, S.; Daughton, W.; Cutler, R.; Fox, W.; Hoffmann, F.; Kalish, M.; Kozub, T.; Jara-Almonte, J.; Myers, C.; Ren, Y.; Sloboda, P.; Yamada, M.; Yoo, J.; Bale, S. D.; Carter, T.; Dorfman, S.; Drake, J.; Egedal, J.; Sarff, J.; Wallace, J.

    2017-10-01

    The FLARE device (Facility for Laboratory Reconnection Experiments; flare.pppl.gov) is a new laboratory experiment under construction at Princeton with first plasmas expected in the fall of 2017, based on the design of Magnetic Reconnection Experiment (MRX; mrx.pppl.gov) with much extended parameter ranges. Its main objective is to provide an experimental platform for the studies of magnetic reconnection and related phenomena in the multiple X-line regimes directly relevant to space, solar, astrophysical and fusion plasmas. The main diagnostics is an extensive set of magnetic probe arrays, simultaneously covering multiple scales from local electron scales ( 2 mm), to intermediate ion scales ( 10 cm), and global MHD scales ( 1 m). Specific example space physics topics which can be studied on FLARE will be discussed.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ottesen, Elizabeth A.; Marin, Roman; Preston, Christina M.

    Planktonic microbial activity and community structure is dynamic, and can change dramatically on time scales of hours to days. Yet for logistical reasons, this temporal scale is typically undersampled in the marine environment. In order to facilitate higher-resolution, long-term observation of microbial diversity and activity, we developed a protocol for automated collection and fixation of marine microbes using the Environmental Sample Processor (ESP) platform. The protocol applies a preservative (RNALater) to cells collected on filters, for long-term storage and preservation of total cellular RNA. Microbial samples preserved using this protocol yielded high-quality RNA after 30 days of storage at roommore » temperature, or onboard the ESP at in situ temperatures. Pyrosequencing of complementary DNA libraries generated from ESP-collected and preserved samples yielded transcript abundance profiles nearly indistinguishable from those derived from conventionally treated replicate samples. To demonstrate the utility of the method, we used a moored ESP to remotely and autonomously collect Monterey Bay seawater for metatranscriptomic analysis. Community RNA was extracted and pyrosequenced from samples collected at four time points over the course of a single day. In all four samples, the oxygenic photoautotrophs were predominantly eukaryotic, while the bacterial community was dominated by Polaribacter-like Flavobacteria and a Rhodobacterales bacterium sharing high similarity with Rhodobacterales sp. HTCC2255. However, each time point was associated with distinct species abundance and gene transcript profiles. These laboratory and field tests confirmed that autonomous collection and preservation is a feasible and useful approach for characterizing the expressed genes and environmental responses of marine microbial communities.« less

  14. The use of an air filtration system in podiatry clinics.

    PubMed

    McLarnon, Nichola; Burrow, Gordon; Maclaren, William; Aidoo, Kofi; Hepher, Mike

    2003-06-01

    A small-scale study was conducted to ascertain the efficiency and effectiveness of an air filtration system for use in podiatry/chiropody clinics (Electromedia Model 35F (A), Clean Air Ltd, Scotland, UK). Three clinics were identified, enabling comparison of data between podiatry clinics in the West of Scotland. The sampling was conducted using a portable Surface Air Sampler (Cherwell Laboratories, Bicester, UK). Samples were taken on two days at three different times before and after installation of the filtration units. The global results of the study indicate the filter has a statistically significant effect on microbial counts, with an average percentage decrease of 65%. This study is the first time, to the authors' knowledge, such a system has been tested within podiatric practice.

  15. Pore scale modelling of electrical and hydraulic properties of a semi-consolidated sandstone under unsaturated conditions

    NASA Astrophysics Data System (ADS)

    Cassiani, G.; dalla, E.; Brovelli, A.; Pitea, D.; Binley, A. M.

    2003-04-01

    The development of reliable constitutive laws to translate geophysical properties into hydrological ones is the fundamental step for successful applications of hydrogeophysical techniques. Many such laws have been proposed and applied, particularly with regard to two types of relationships: (a) between moisture content and dielectric properties, and (b) between electrical resistivity, rock structure and water saturation. The classical Archie's law belongs to this latter category. Archie's relationship has been widely used, starting from borehole logs applications, to translate geoelectrical measurements into estimates of saturation. However, in spite of its popularity, it remains an empirical relationship, the parameters of which must be calibrated case by case, e.g. on laboratory data. Pore-scale models have been recently recognized and used as powerful tools to investigate the constitutive relations of multiphase soils from a pore-scale point of view, because they bridge the microscopic and macroscopic scales. In this project, we develop and validate a three-dimensional pore-scale method to compute electrical properties of unsaturated and saturated porous media. First we simulate a random packing of spheres [1] that obeys the grain-size distribution and porosity of an experimental porous medium system; then we simulate primary drainage with a morphological approach [2]; finally, for each state of saturation during the drainage process, we solve the electrical conduction equation within the grain structure with a new numerical model and compute the apparent electrical resistivity of the porous medium. We apply the new method to a semi-consolidated Permo-Triassic Sandstone from the UK (Sherwood Sandstone) for which both pressure-saturation (Van Genuchten) and Archie's law parameters have been measured on laboratory samples. A comparison between simulated and measured relationships has been performed.

  16. Analysis of small-angle X-ray scattering data in the presence of significant instrumental smearing

    PubMed Central

    Bergenholtz, Johan; Ulama, Jeanette; Zackrisson Oskolkova, Malin

    2016-01-01

    A laboratory-scale small-angle X-ray scattering instrument with pinhole collimation has been used to assess smearing effects due to instrumental resolution. A new, numerically efficient method to smear ideal model intensities is developed and presented. It allows for directly using measured profiles of isotropic but otherwise arbitrary beams in smearing calculations. Samples of low-polydispersity polymer spheres have been used to show that scattering data can in this way be quantitatively modeled even when there is substantial distortion due to instrumental resolution. PMID:26937235

  17. Hydrocarbon-soluble low-melting corrosion inhibitor TAL-3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nesterenko, S.A.; Sorokin, V.I.; Naumenko, O.V.

    1987-03-01

    The inhibitor TAL-3 is intended for the corrosion protection of metals that come into contact with two-phase systems of the hydrocarbon-water type. It is applicable to the service conditions of equipment and pipelines of the petroleum and petroleum refining industries. The purpose of this paper was to electrochemically assess its solubility in such systems and its inhibitory properties on samples of 08kp steel toward the effects of refinery and oil field waste water and process emulsions both on the laboratory scale and in field tests.

  18. Spectroscopic measurements of muzzle flash plasma

    NASA Astrophysics Data System (ADS)

    Uglum, J. R.

    1986-11-01

    The experimental apparatus and sample data for the muzzle flash plasma of a laboratory-scale railgun are described. Theoretical predictions for the railgun system configuration used indicated that 24 kJ of energy would be dissipated by the muzzle flash. Spectral data were recorded with a spectrograph sensing through a slit and a PIN diode, the latter to obtain temporal resolution in the data. The tests featured a plastic projectile with an Al foil armature. The measurements identified Cu as the dominant flash material, ablated from the rails in the barrel.

  19. Engineering and Development Support of General Decon Technology for the U.S. Army’s Installation Restoration Program. Task 11. Composting of Explosives

    DTIC Science & Technology

    1982-09-01

    parallei studies ý7.fLtoring TNT and liDX disappearance in laboratory scale (50 g dry weight) and greenhouse (10 kg dry weight) compost,. An additional...occurred during composting. The greenhouse compost studies demonstrated a very rapid decrease in the TNT concentration. At the three week sampling time...material was below the detecuion limit of 16.9 ppm. Greenhouse composting of RDX resulted in a 61% reduction in the RDX concentration after three weeks

  20. Screening of ground water samples for volatile organic compounds using a portable gas chromatograph

    USGS Publications Warehouse

    Buchmiller, R.C.

    1989-01-01

    A portable gas chromatograph was used to screen 32 ground water samples for volatile organic compounds. Seven screened samples were positive; four of the seven samples had volatile organic substances identified by second-column confirmation. Four of the seven positive, screened samples also tested positive in laboratory analyses of duplicate samples. No volatile organic compounds were detected in laboratory analyses of samples that headspace screening indicated to be negative. Samples that contained volatile organic compounds, as identified by laboratory analysis, and that contained a volatile organic compound present in a standard of selected compounds were correctly identified by using the portable gas chromatography. Comparisons of screened-sample data with laboratory data indicate the ability to detect selected volatile organic compounds at concentrations of about 1 microgram per liter in the headspace of water samples by use of a portable gas chromatography. -Author

  1. Structural ceramics containing electric arc furnace dust.

    PubMed

    Stathopoulos, V N; Papandreou, A; Kanellopoulou, D; Stournaras, C J

    2013-11-15

    In the present work the stabilization of electric arc furnace dust EAFD waste in structural clay ceramics was investigated. EAFD was collected over eleven production days. The collected waste was characterized for its chemical composition by Flame Atomic Absorption Spectroscopy. By powder XRD the crystal structure was studied while the fineness of the material was determined by a laser particle size analyzer. The environmental characterization was carried out by testing the dust according to EN12457 standard. Zn, Pb and Cd were leaching from the sample in significant amounts. The objective of this study is to investigate the stabilization properties of EAFD/clay ceramic structures and the potential of EAFD utilization into structural ceramics production (blocks). Mixtures of clay with 2.5% and 5% EAFD content were studied by TG/DTA, XRD, SEM, EN12457 standard leaching and mechanical properties as a function of firing temperature at 850, 900 and 950 °C. All laboratory facilities maintained 20 ± 1 °C. Consequently, a pilot-scale experiment was conducted with an addition of 2.5% and 5% EAFD to the extrusion mixture for the production of blocks. During blocks manufacturing, the firing step reached 950 °C in a tunnel kiln. Laboratory heating/cooling gradients were similar to pilot scale production firing. The as produced blocks were then subjected to quality control tests, i.e. dimensions according to EN772-17, water absorbance according to EN772-6, and compressive strength according to EN772-1 standard, in laboratory facilities certified under EN17025. The data obtained showed that the incorporation of EAFD resulted in an increase of mechanical strength. Moreover, leaching tests performed according to the Europeans standards on the EAFD-block samples showed that the quantities of heavy metals leached from crushed blocks were within the regulatory limits. Thus the EAFD-blocks can be regarded as material of no environmental concern. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. A measurement routine to determine 137Cs activities at steep mountain slopes

    NASA Astrophysics Data System (ADS)

    Schaub, Monika; Konz, Nadine; Meusburger, Katrin; Alewell, Chrstine

    2010-05-01

    Caesium-137 (137Cs) is a common tracer for soil erosion. So far, in-situ measurements in steep alpine environments have not often been done. Most studies have been carried out in arable lands and with Ge detectors. However, the NaI detector system is a good priced, easy to handle field instrument. A comparison of laboratory measurements with GeLi detector and in-situ measurements with NaI detector of 137Cs gamma soil radiation has been done in an alpine catchment (Urseren Valley, Swizerland). The aim of this study was to calibrate the in-situ NaI detector system for application at steep alpine slopes. Replicate samples from an altitudinal transect through the Urseren Valley were measured ex situ in the laboratory with a GeLi detector, and compared to in situ NaI detector measurements. Ex situ soil samples showed a big variability in 137Cs activities at a meter-scale. This large, small scale heterogeneity determined with the GeLi detector is smoothed out by uncollimated in-situ measurements with the NaI detector, which provide integrated estimates of 137Cs within the field of view of each measurement (3.1 m2). There was no dependency of 137Cs on pH, clay content and carbon content. However, a close relationship was determined between 137Cs and soil moisture. Thus, in-situ data must be corrected for soil moisture. Close correlation (R2 = 0.86) was found for 137Cs activities (in Bq kg-1) estimated with both, in-situ (NaI detector) and laboratory (GeLi detector) methods which proves the validity of the in-situ measurements with the NaI detector system. This paper describes the calibration of the NaI detector system for field application under elevated 137Cs activities originating from Chernobyl fallout.

  3. Element concentrations in soils and other surficial materials of Alaska

    USGS Publications Warehouse

    Gough, L.P.; Severson, R.C.; Shacklette, H.T.

    1988-01-01

    Mean concentrations of 35 elements, ash yields, and pH have been estimated for samples of sils and other unconsolidated surficial materials from 266 collection locations throughout Alaska. These background values can be applied to studies of environmental geochemistry and health, wildlife management, and soil-forming processes in cold climates and to computation of element abundances on a regional or worldwide scale. Limited data for an additoinal eight elements are also presented. Materials were collected using a one-way, three-level, analysis-of-variance samplling design in which collecting procedures were simplified for the convenience of the many volunteer field workers. The sample collectors were asked to avoid locations of known mineral deposits and obvious contamination, to take samples at a depth of about 20 cm where possible, and to take a replicate sample about 100 m distant from the first sample collected. With more than 60 percent of the samples replicated and 14 percent of the samples split for duplicate laboratory analyses, reliable estimates were made of the variability in element concentrations at two geographic scales and of the error associated with sample handling and laboratory procedures. Mean concentrations of most elements in surficial materials from the state of alaska correspond well with those reported in similar materials from the conterminous United STatess. Most element concentrations and ranges in samples of stream and lake sediments from Alaska, however, as reported in the literature, do not correspond well with those found in surficial materials of this study. This lack of correspondence is attributed to (1) a merger of two kinds ofsediments (stream and lake) for calculating means; (2) elimination from the sediment mean calculations of values below the limit of quantitative determination; (3) analytical methods different from those of the surficial materials study; and (4) most importantly, the inherent differences in chemistry of the materials. The distribution of variability in element concentrations o Alaskan surficial-material samples was, for most elements, largely among sampling locations, with only a samll part of the variability occurring between replicate samples at a location. The geochemical uniformity within sampling locations in Alaska is an expression of uniform geochemical cycling processes within small geographic areas. The concentration values for 35 elements in 266 samples were plotted on maps by symbols representing classes of concentration frequency distributions. These plotted symbols form patterns that may or may not be possible to interpret but nevertheless show differences that are observable at several geographical scales. The largest pattern is one generally low concentrations of many elements in materials from arctic and oceanic tundra regions, as contrasted to their often high concentrations in samples from interior and southeastern Alaska. The patttern for sodium isespecially pronounced. Intermediate-sized patterns are shown, for example, by the generally high values for magnesium and low values for silicon in the coastal forest region of southeastern Alaska. Many elements occur at low concentratoins in samples from the Alaskan peninsula and the Aleutian Islands. The degree of confidence in patterns of element abundance is expected to be in direct proportion to the number of samples included in the area. As the patterns become smaller, the probability increases that the patterns are not reproducible.

  4. Successful Sampling Strategy Advances Laboratory Studies of NMR Logging in Unconsolidated Aquifers

    NASA Astrophysics Data System (ADS)

    Behroozmand, Ahmad A.; Knight, Rosemary; Müller-Petke, Mike; Auken, Esben; Barfod, Adrian A. S.; Ferré, Ty P. A.; Vilhelmsen, Troels N.; Johnson, Carole D.; Christiansen, Anders V.

    2017-11-01

    The nuclear magnetic resonance (NMR) technique has become popular in groundwater studies because it responds directly to the presence and mobility of water in a porous medium. There is a need to conduct laboratory experiments to aid in the development of NMR hydraulic conductivity models, as is typically done in the petroleum industry. However, the challenge has been obtaining high-quality laboratory samples from unconsolidated aquifers. At a study site in Denmark, we employed sonic drilling, which minimizes the disturbance of the surrounding material, and extracted twelve 7.6 cm diameter samples for laboratory measurements. We present a detailed comparison of the acquired laboratory and logging NMR data. The agreement observed between the laboratory and logging data suggests that the methodologies proposed in this study provide good conditions for studying NMR measurements of unconsolidated near-surface aquifers. Finally, we show how laboratory sample size and condition impact the NMR measurements.

  5. Semiconductor Chemical Reactor Engineering and Photovoltaic Unit Operations.

    ERIC Educational Resources Information Center

    Russell, T. W. F.

    1985-01-01

    Discusses the nature of semiconductor chemical reactor engineering, illustrating the application of this engineering with research in physical vapor deposition of cadmium sulfide at both the laboratory and unit operations scale and chemical vapor deposition of amorphous silicon at the laboratory scale. (JN)

  6. Temperature Evolution During Plane Strain Compression Of Tertiary Oxide Scale On Steel

    NASA Astrophysics Data System (ADS)

    Suarez, L.; Vanden Eynde, X.; Lamberigts, M.; Houbaert, Y.

    2007-04-01

    An oxide scale layer always forms at the steel surface during hot rolling. This scale layer separates the work roll from the metal substrate. Understanding the deformation behaviour and mechanical properties of the scale is of great interest because it affects the frictional conditions during hot rolling and the heat-transfer behaviour at the strip-roll interface. A thin wustite scale layer (<20 μm) was created under controlled conditions in an original laboratory device adequately positioned in a compression testing machine to investigate plane strain compression. Oxidation tests were performed on an ULC steel grade. After the oxide growth at 1050°C, plane strain compression (PSC) was performed immediately to simulate the hot rolling process. PSC experiments were performed at a deformation temperature of 1050°C, with reduction ratios from 5 to 70%, and strain rates of 10s-1 under controlled gas atmospheres. Results show that for wustite, ductility is obvious at 1050°C. Even after deformation oxide layers exhibit good adhesion to the substrate and homogeneity over the thickness. The tool/sample temperature difference seems to be the reason for the unexpected ductile behaviour of the scale layer.

  7. Hydrogeochemical and stream sediment reconnaissance basic data for Roswell quadrangle, New Mexico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    Field and laboratory data are presented for 842 water samples and 1270 sediment samples from the Roswell Quadrangle, New Mexico. The samples were collected by Los Alamos National Laboratory; laboratory analysis and data reporting were performed by the Uranium Resource Evaluation Project at Oak Ridge, Tennessee.

  8. New Experimental Technique for Nodularity and Mg Fading Control in Compacted Graphite Iron Production on Laboratory Scale

    NASA Astrophysics Data System (ADS)

    Hernando, Juan Carlos; Domeij, Björn; González, Daniel; Amieva, José Manuel; Diószegi, Attila

    2017-11-01

    The narrow production window for compacted graphite iron material (CGI) drastically reduces the possibilities to produce it in small batches outside an industrial environment. This fact hinders laboratory-scale investigations on CGI solidification. This work presents a solution to that issue by introducing an experimental technique to produce graphitic cast iron of the main three families. Samples of a base hypereutectic spheroidal graphite iron (SGI) were re-melted in a resistance furnace under Ar atmosphere. Varying the holding time at 1723 K (1450 °C), graphitic irons ranging from spheroidal to lamellar were produced. Characterization of the graphite morphology evolution, in terms of nodularity as a function of holding time, is presented. The nodularity decay for the SGI region suggests a linear correlation with the holding time. In the CGI region, nodularity deterioration shows a slower rate, concluding with the sudden appearance of lamellar graphite. The fading process of magnesium, showing agreement with previous researchers, is described by means of empirical relations as a function of holding time and nodularity. The results on nodularity fade and number of nodules per unit area fade suggest that both phenomena occur simultaneously during the fading process of magnesium.

  9. Capillary pressure heterogeneity and hysteresis for the supercritical CO2/water system in a sandstone

    NASA Astrophysics Data System (ADS)

    Pini, Ronny; Benson, Sally M.

    2017-10-01

    We report results from an experimental investigation on the hysteretic behaviour of the capillary pressure curve for the supercritical CO2-water system in a Berea Sandstone core. Previous observations have highlighted the importance of subcore-scale capillary heterogeneity in developing local saturations during drainage; we show in this study that the same is true for the imbibition process. Spatially distributed drainage and imbibition scanning curves were obtained for mm-scale subsets of the rock sample non-invasively using X-ray CT imagery. Core- and subcore-scale measurements are well described using the Brooks-Corey formalism, which uses a linear trapping model to compute mobile saturations during imbibition. Capillary scaling yields two separate universal drainage and imbibition curves that are representative of the full subcore-scale data set. This enables accurate parameterisation of rock properties at the subcore-scale in terms of capillary scaling factors and permeability, which in turn serve as effective indicators of heterogeneity at the same scale even when hysteresis is a factor. As such, the proposed core-analysis workflow is quite general and provides the required information to populate numerical models that can be used to extend core-flooding experiments to conditions prevalent in the subsurface, which would be otherwise not attainable in the laboratory.

  10. Quantitative Real-Time Legionella PCR for Environmental Water Samples: Data Interpretation

    PubMed Central

    Joly, Philippe; Falconnet, Pierre-Alain; André, Janine; Weill, Nicole; Reyrolle, Monique; Vandenesch, François; Maurin, Max; Etienne, Jerome; Jarraud, Sophie

    2006-01-01

    Quantitative Legionella PCRs targeting the 16S rRNA gene (specific for the genus Legionella) and the mip gene (specific for the species Legionella pneumophila) were applied to a total of 223 hot water system samples (131 in one laboratory and 92 in another laboratory) and 37 cooling tower samples (all in the same laboratory). The PCR results were compared with those of conventional culture. 16S rRNA gene PCR results were nonquantifiable for 2.8% of cooling tower samples and up to 39.1% of hot water system samples, and this was highly predictive of Legionella CFU counts below 250/liter. PCR cutoff values for identifying hot water system samples containing >103 CFU/liter legionellae were determined separately in each laboratory. The cutoffs differed widely between the laboratories and had sensitivities from 87.7 to 92.9% and specificities from 77.3 to 96.5%. The best specificity was obtained with mip PCR. PCR cutoffs could not be determined for cooling tower samples, as the results were highly variable and often high for culture-negative samples. Thus, quantitative Legionella PCR appears to be applicable to samples from hot water systems, but the positivity cutoff has to be determined in each laboratory. PMID:16597985

  11. Evolution of strength and physical properties of carbonate and ultramafic rocks under hydrothermal conditions

    NASA Astrophysics Data System (ADS)

    Lisabeth, Harrison Paul

    Interaction of rocks with fluids can significantly change mineral assemblage and structure. This so-called hydrothermal alteration is ubiquitous in the Earth's crust. Though the behavior of hydrothermally altered rocks can have planet-scale consequences, such as facilitating oceanic spreading along slow ridge segments and recycling volatiles into the mantle at subduction zones, the mechanisms involved in the hydrothermal alteration are often microscopic. Fluid-rock interactions take place where the fluid and rock meet. Fluid distribution, flux rate and reactive surface area control the efficiency and extent of hydrothermal alteration. Fluid-rock interactions, such as dissolution, precipitation and fluid mediated fracture and frictional sliding lead to changes in porosity and pore structure that feed back into the hydraulic and mechanical behavior of the bulk rock. Examining the nature of this highly coupled system involves coordinating observations of the mineralogy and structure of naturally altered rocks and laboratory investigation of the fine scale mechanisms of transformation under controlled conditions. In this study, I focus on fluid-rock interactions involving two common lithologies, carbonates and ultramafics, in order to elucidate the coupling between mechanical, hydraulic and chemical processes in these rocks. I perform constant strain-rate triaxial deformation and constant-stress creep tests on several suites of samples while monitoring the evolution of sample strain, permeability and physical properties. Subsequent microstructures are analyzed using optical and scanning electron microscopy. This work yields laboratory-based constraints on the extent and mechanisms of water weakening in carbonates and carbonation reactions in ultramafic rocks. I find that inundation with pore fluid thereby reducing permeability. This effect is sensitive to pore fluid saturation with respect to calcium carbonate. Fluid inundation weakens dunites as well. The addition of carbon dioxide to pore fluid enhances compaction and partial recovery of strength compared to pure water samples. Enhanced compaction in CO2-rich fluid samples is not accompanied by enhanced permeability reduction. Analysis of sample microstructures indicates that precipitation of carbonates along fracture surfaces is responsible for the partial restrengthening and channelized dissolution of olivine is responsible for permeability maintenance.

  12. Manufacturing Laboratory | Energy Systems Integration Facility | NREL

    Science.gov Websites

    Manufacturing Laboratory Manufacturing Laboratory Researchers in the Energy Systems Integration Facility's Manufacturing Laboratory develop methods and technologies to scale up renewable energy technology manufacturing capabilities. Photo of researchers and equipment in the Manufacturing Laboratory. Capability Hubs

  13. Laboratory assessment of novel oral anticoagulants: method suitability and variability between coagulation laboratories.

    PubMed

    Helin, Tuukka A; Pakkanen, Anja; Lassila, Riitta; Joutsi-Korhonen, Lotta

    2013-05-01

    Laboratory tests to assess novel oral anticoagulants (NOACs) are under evaluation. Routine monitoring is unnecessary, but under special circumstances bioactivity assessment becomes crucial. We analyzed the effects of NOACs on coagulation tests and the availability of specific assays at different laboratories. Plasma samples spiked with dabigatran (Dabi; 120 and 300 μg/L) or rivaroxaban (Riva; 60, 146, and 305 μg/L) were sent to 115 and 38 European laboratories, respectively. International normalized ratio (INR) and activated partial thromboplastin time (APTT) were analyzed for all samples; thrombin time (TT) was analyzed specifically for Dabi and calibrated anti-activated factor X (anti-Xa) activity for Riva. We compared the results with patient samples. Results of Dabi samples were reported by 73 laboratories (13 INR and 9 APTT reagents) and Riva samples by 22 laboratories (5 INR and 4 APTT reagents). Both NOACs increased INR values; the increase was modest, albeit larger, for Dabi, with higher CV, especially with Quick (vs Owren) methods. Both NOACs dose-dependently prolonged the APTT. Again, the prolongation and CVs were larger for Dabi. The INR and APTT results varied reagent-dependently (P < 0.005), with less prolongation in patient samples. TT results (Dabi) and calibrated anti-Xa results (Riva) were reported by only 11 and 8 laboratories, respectively. The screening tests INR and APTT are suboptimal in assessing NOACs, having high reagent dependence and low sensitivity and specificity. They may provide information, if laboratories recognize their limitations. The variation will likely increase and the sensitivity differ in clinical samples. Specific assays measure NOACs accurately; however, few laboratories applied them. © 2013 American Association for Clinical Chemistry.

  14. A laboratory nanoseismological study on deep-focus earthquake micromechanics

    DOE PAGES

    Wang, Yanbin; Zhu, Lupei; Shi, Feng; ...

    2017-07-21

    Global earthquake occurring rate displays an exponential decay down to ~300 km and then peaks around 550 to 600 km before terminating abruptly near 700 km. How fractures initiate, nucleate, and propagate at these depths remains one of the greatest puzzles in earth science, as increasing pressure inhibits fracture propagation. We report nanoseismological analysis on high-resolution acoustic emission (AE) records obtained during ruptures triggered by partial transformation from olivine to spinel in Mg 2GeO 4, an analog to the dominant mineral (Mg,Fe) 2SiO 4 olivine in the upper mantle, using state-of-the-art seismological techniques, in the laboratory. AEs’ focal mechanisms, asmore » well as their distribution in both space and time during deformation, are carefully analyzed. Microstructure analysis shows that AEs are produced by the dynamic propagation of shear bands consisting of nanograined spinel. These nanoshear bands have a near constant thickness (~100 nm) but varying lengths and self-organize during deformation. This precursory seismic process leads to ultimate macroscopic failure of the samples. Several source parameters of AE events were extracted from the recorded waveforms, allowing close tracking of event initiation, clustering, and propagation throughout the deformation/transformation process. AEs follow the Gutenberg-Richter statistics with a well-defined b value of 1.5 over three orders of moment magnitudes, suggesting that laboratory failure processes are self-affine. The seismic relation between magnitude and rupture area correctly predicts AE magnitude at millimeter scales. A rupture propagation model based on strain localization theory is proposed. Future numerical analyses may help resolve scaling issues between laboratory AE events and deep-focus earthquakes.« less

  15. A laboratory nanoseismological study on deep-focus earthquake micromechanics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Yanbin; Zhu, Lupei; Shi, Feng

    Global earthquake occurring rate displays an exponential decay down to ~300 km and then peaks around 550 to 600 km before terminating abruptly near 700 km. How fractures initiate, nucleate, and propagate at these depths remains one of the greatest puzzles in earth science, as increasing pressure inhibits fracture propagation. We report nanoseismological analysis on high-resolution acoustic emission (AE) records obtained during ruptures triggered by partial transformation from olivine to spinel in Mg2GeO4, an analog to the dominant mineral (Mg,Fe)2SiO4 olivine in the upper mantle, using state-of-the-art seismological techniques, in the laboratory. AEs’ focal mechanisms, as well as their distributionmore » in both space and time during deformation, are carefully analyzed. Microstructure analysis shows that AEs are produced by the dynamic propagation of shear bands consisting of nanograined spinel. These nanoshear bands have a near constant thickness (~100 nm) but varying lengths and self-organize during deformation. This precursory seismic process leads to ultimate macroscopic failure of the samples. Several source parameters of AE events were extracted from the recorded waveforms, allowing close tracking of event initiation, clustering, and propagation throughout the deformation/transformation process. AEs follow the Gutenberg-Richter statistics with a well-defined b value of 1.5 over three orders of moment magnitudes, suggesting that laboratory failure processes are self-affine. The seismic relation between magnitude and rupture area correctly predicts AE magnitude at millimeter scales. A rupture propagation model based on strain localization theory is proposed. Future numerical analyses may help resolve scaling issues between laboratory AE events and deep-focus earthquakes.« less

  16. A laboratory nanoseismological study on deep-focus earthquake micromechanics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Yanbin; Zhu, Lupei; Shi, Feng

    Global earthquake occurring rate displays an exponential decay down to ~300 km and then peaks around 550 to 600 km before terminating abruptly near 700 km. How fractures initiate, nucleate, and propagate at these depths remains one of the greatest puzzles in earth science, as increasing pressure inhibits fracture propagation. We report nanoseismological analysis on high-resolution acoustic emission (AE) records obtained during ruptures triggered by partial transformation from olivine to spinel in Mg 2GeO 4, an analog to the dominant mineral (Mg,Fe) 2SiO 4 olivine in the upper mantle, using state-of-the-art seismological techniques, in the laboratory. AEs’ focal mechanisms, asmore » well as their distribution in both space and time during deformation, are carefully analyzed. Microstructure analysis shows that AEs are produced by the dynamic propagation of shear bands consisting of nanograined spinel. These nanoshear bands have a near constant thickness (~100 nm) but varying lengths and self-organize during deformation. This precursory seismic process leads to ultimate macroscopic failure of the samples. Several source parameters of AE events were extracted from the recorded waveforms, allowing close tracking of event initiation, clustering, and propagation throughout the deformation/transformation process. AEs follow the Gutenberg-Richter statistics with a well-defined b value of 1.5 over three orders of moment magnitudes, suggesting that laboratory failure processes are self-affine. The seismic relation between magnitude and rupture area correctly predicts AE magnitude at millimeter scales. A rupture propagation model based on strain localization theory is proposed. Future numerical analyses may help resolve scaling issues between laboratory AE events and deep-focus earthquakes.« less

  17. Biohazards Assessment in Large-Scale Zonal Centrifugation

    PubMed Central

    Baldwin, C. L.; Lemp, J. F.; Barbeito, M. S.

    1975-01-01

    A study was conducted to determine the biohazards associated with use of the large-scale zonal centrifuge for purification of moderate risk oncogenic viruses. To safely and conveniently assess the hazard, coliphage T3 was substituted for the virus in a typical processing procedure performed in a National Cancer Institute contract laboratory. Risk of personnel exposure was found to be minimal during optimal operation but definite potential for virus release from a number of centrifuge components during mechanical malfunction was shown by assay of surface, liquid, and air samples collected during the processing. High concentration of phage was detected in the turbine air exhaust and the seal coolant system when faulty seals were employed. The simulant virus was also found on both centrifuge chamber interior and rotor surfaces. Images PMID:1124921

  18. Scaling up HIV viral load - lessons from the large-scale implementation of HIV early infant diagnosis and CD4 testing.

    PubMed

    Peter, Trevor; Zeh, Clement; Katz, Zachary; Elbireer, Ali; Alemayehu, Bereket; Vojnov, Lara; Costa, Alex; Doi, Naoko; Jani, Ilesh

    2017-11-01

    The scale-up of effective HIV viral load (VL) testing is an urgent public health priority. Implementation of testing is supported by the availability of accurate, nucleic acid based laboratory and point-of-care (POC) VL technologies and strong WHO guidance recommending routine testing to identify treatment failure. However, test implementation faces challenges related to the developing health systems in many low-resource countries. The purpose of this commentary is to review the challenges and solutions from the large-scale implementation of other diagnostic tests, namely nucleic-acid based early infant HIV diagnosis (EID) and CD4 testing, and identify key lessons to inform the scale-up of VL. Experience with EID and CD4 testing provides many key lessons to inform VL implementation and may enable more effective and rapid scale-up. The primary lessons from earlier implementation efforts are to strengthen linkage to clinical care after testing, and to improve the efficiency of testing. Opportunities to improve linkage include data systems to support the follow-up of patients through the cascade of care and test delivery, rapid sample referral networks, and POC tests. Opportunities to increase testing efficiency include improvements to procurement and supply chain practices, well connected tiered laboratory networks with rational deployment of test capacity across different levels of health services, routine resource mapping and mobilization to ensure adequate resources for testing programs, and improved operational and quality management of testing services. If applied to VL testing programs, these approaches could help improve the impact of VL on ART failure management and patient outcomes, reduce overall costs and help ensure the sustainable access to reduced pricing for test commodities, as well as improve supportive health systems such as efficient, and more rigorous quality assurance. These lessons draw from traditional laboratory practices as well as fields such as logistics, operations management and business. The lessons and innovations from large-scale EID and CD4 programs described here can be adapted to inform more effective scale-up approaches for VL. They demonstrate that an integrated approach to health system strengthening focusing on key levers for test access such as data systems, supply efficiencies and network management. They also highlight the challenges with implementation and the need for more innovative approaches and effective partnerships to achieve equitable and cost-effective test access. © 2017 The Authors. Journal of the International AIDS Society published by John Wiley & sons Ltd on behalf of the International AIDS Society.

  19. A Laboratory-Based System for Managing and Distributing Publically Funded Geochemical Data in a Collaborative Environment

    NASA Astrophysics Data System (ADS)

    McInnes, B.; Brown, A.; Liffers, M.

    2015-12-01

    Publically funded laboratories have a responsibility to generate, archive and disseminate analytical data to the research community. Laboratory managers know however, that a long tail of analytical effort never escapes researchers' thumb drives once they leave the lab. This work reports on a research data management project (Digital Mineralogy Library) where integrated hardware and software systems automatically archive and deliver analytical data and metadata to institutional and community data portals. The scientific objective of the DML project was to quantify the modal abundance of heavy minerals extracted from key lithological units in Western Australia. The selected analytical platform was a TESCAN Integrated Mineral Analyser (TIMA) that uses EDS-based mineral classification software to image and quantify mineral abundance and grain size at micron scale resolution. The analytical workflow used a bespoke laboratory information management system (LIMS) to orchestrate: (1) the preparation of grain mounts with embedded QR codes that serve as enduring links between physical samples and analytical data, (2) the assignment of an International Geo Sample Number (IGSN) and Digital Object Identifier (DOI) to each grain mount via the System for Earth Sample Registry (SESAR), (3) the assignment of a DOI to instrument metadata via Research Data Australia, (4) the delivery of TIMA analytical outputs, including spatially registered mineralogy images and mineral abundance data, to an institutionally-based data management server, and (5) the downstream delivery of a final data product via a Google Maps interface such as the AuScope Discovery Portal. The modular design of the system permits the networking of multiple instruments within a single site or multiple collaborating research institutions. Although sharing analytical data does provide new opportunities for the geochemistry community, the creation of an open data network requires: (1) adopting open data reporting standards and conventions, (2) requiring instrument manufacturers and software developers to deliver and process data in formats compatible with open standards, and (3) public funding agencies to incentivise researchers, laboratories and institutions to make their data open and accessible to consumers.

  20. bigSCale: an analytical framework for big-scale single-cell data.

    PubMed

    Iacono, Giovanni; Mereu, Elisabetta; Guillaumet-Adkins, Amy; Corominas, Roser; Cuscó, Ivon; Rodríguez-Esteban, Gustavo; Gut, Marta; Pérez-Jurado, Luis Alberto; Gut, Ivo; Heyn, Holger

    2018-06-01

    Single-cell RNA sequencing (scRNA-seq) has significantly deepened our insights into complex tissues, with the latest techniques capable of processing tens of thousands of cells simultaneously. Analyzing increasing numbers of cells, however, generates extremely large data sets, extending processing time and challenging computing resources. Current scRNA-seq analysis tools are not designed to interrogate large data sets and often lack sensitivity to identify marker genes. With bigSCale, we provide a scalable analytical framework to analyze millions of cells, which addresses the challenges associated with large data sets. To handle the noise and sparsity of scRNA-seq data, bigSCale uses large sample sizes to estimate an accurate numerical model of noise. The framework further includes modules for differential expression analysis, cell clustering, and marker identification. A directed convolution strategy allows processing of extremely large data sets, while preserving transcript information from individual cells. We evaluated the performance of bigSCale using both a biological model of aberrant gene expression in patient-derived neuronal progenitor cells and simulated data sets, which underlines the speed and accuracy in differential expression analysis. To test its applicability for large data sets, we applied bigSCale to assess 1.3 million cells from the mouse developing forebrain. Its directed down-sampling strategy accumulates information from single cells into index cell transcriptomes, thereby defining cellular clusters with improved resolution. Accordingly, index cell clusters identified rare populations, such as reelin ( Reln )-positive Cajal-Retzius neurons, for which we report previously unrecognized heterogeneity associated with distinct differentiation stages, spatial organization, and cellular function. Together, bigSCale presents a solution to address future challenges of large single-cell data sets. © 2018 Iacono et al.; Published by Cold Spring Harbor Laboratory Press.

  1. [Study on the reproducibility of ACTH concentrations in plasma of horses with and without equine Cushing syndrome].

    PubMed

    Gehlen, Heidrun; Bradaric, Zrinkja

    2013-01-01

    The evaluation of plasma ACTH and the dexamethasone suppression test are considered the methods of choice to evaluate the course of therapy of pituitary pars intermedia dysfunction (PPID). Sampling protocols as well as vacutainers for analysis differ between the laboratories. To evaluate the reproducability of plasma ACTH measurement between four different laboratories (A, B, C, D) in Germany as well as within the laboratories themselves, ten horses with previously diagnosed PPID and four healthy horses were sampled and analyzed. Each laboratory received two differently labeled samples of each horse which had been drawn at the same time (blinded samples). Sampling was performed in the morning at the same time. The sampling vacutainers (with and without addition of coagulation and proteinase inhibitors) and postage of the samples was performed according to laboratory standards. In one laboratory the influence of the time of centrifugation (immediately after taking blood versus after one hour) was determined. The samples were processed and analyzed according to laboratory protocols. Determination of ACTH levels was performed using chemiluminescence immunoassay. In total 132 blood samples were analyzed. The results of doubled blood samples of the same horse showed a standard deviation ranging from +/- 6 to +/- 27 pg/ml within the laboratories (Ø 19,29 pg/ml). The standard deviation of the repeatability of the variation coefficient was 13,48%. Blood samples of the same horse resulted in ACTH levels of 121 pg/ml in the first probe and in < 5 pg/ml in the second probe. Standard deviation of measured ACTH values between the laboratories was +/- 26,4 pg/ml (Ø 27,44 pg/ml). The standard deviation of the reproducibility of the variation coefficient was 18,36%. In a 20 year old gelding the lowest ACTH value was 60.9 pg/ml whereas the highest measured value was 108 pg/ml. Immediate centrifugation of blood samples resulted in significantly higher ACTH values at an average of 11.6 pg/ml. The additional use of proteinase inhibitors (aprotinine) showed no influence on ACTH levels in this study.

  2. Can current analytical quality performance of UK clinical laboratories support evidence-based guidelines for diabetes and ischaemic heart disease?--A pilot study and a proposal.

    PubMed

    Jassam, Nuthar; Yundt-Pacheco, John; Jansen, Rob; Thomas, Annette; Barth, Julian H

    2013-08-01

    The implementation of national and international guidelines is beginning to standardise clinical practice. However, since many guidelines have decision limits based on laboratory tests, there is an urgent need to ensure that different laboratories obtain the same analytical result on any sample. A scientifically-based quality control process will be a pre-requisite to provide this level of analytical performance which will support evidence-based guidelines and movement of patients across boundaries while maintaining standardised outcomes. We discuss the finding of a pilot study performed to assess UK clinical laboratories readiness to work to a higher grade quality specifications such as biological variation-based quality specifications. Internal quality control (IQC) data for HbA1c, glucose, creatinine, cholesterol and high density lipoprotein (HDL)-cholesterol were collected from UK laboratories participating in the Bio-Rad Unity QC programme. The median of the coefficient of variation (CV%) of the participating laboratories was evaluated against the CV% based on biological variation. Except creatinine, the other four analytes had a variable degree of compliance with the biological variation-based quality specifications. More than 75% of the laboratories met the biological variation-based quality specifications for glucose, cholesterol and HDL-cholesterol. Slightly over 50% of the laboratories met the analytical goal for HBA1c. Only one analyte (cholesterol) had a performance achieving the higher quality specifications consistent with 5σ. Our data from IQC do not consistently demonstrate that the results from clinical laboratories meet evidence-based quality specifications. Therefore, we propose that a graded scale of quality specifications may be needed at this stage.

  3. Improving catchment scale water quality modelling with continuous high resolution monitoring of metals in runoff

    NASA Astrophysics Data System (ADS)

    Saari, Markus; Rossi, Pekka; Blomberg von der Geest, Kalle; Mäkinen, Ari; Postila, Heini; Marttila, Hannu

    2017-04-01

    High metal concentrations in natural waters is one of the key environmental and health problems globally. Continuous in-situ analysis of metals from runoff water is technically challenging but essential for the better understanding of processes which lead to pollutant transport. Currently, typical analytical methods for monitoring elements in liquids are off-line laboratory methods such as ICP-OES (Inductively Coupled Plasma Optical Emission Spectroscopy) and ICP-MS (ICP combined with a mass spectrometer). Disadvantage of the both techniques is time consuming sample collection, preparation, and off-line analysis at laboratory conditions. Thus use of these techniques lack possibility for real-time monitoring of element transport. We combined a novel high resolution on-line metal concentration monitoring with catchment scale physical hydrological modelling in Mustijoki river in Southern Finland in order to study dynamics of processes and form a predictive warning system for leaching of metals. A novel on-line measurement technique based on micro plasma emission spectroscopy (MPES) is tested for on-line detection of selected elements (e.g. Na, Mg, Al, K, Ca, Fe, Ni, Cu, Cd and Pb) in runoff waters. The preliminary results indicate that MPES can sufficiently detect and monitor metal concentrations from river water. Water and Soil Assessment Tool (SWAT) catchment scale model was further calibrated with high resolution metal concentration data. We show that by combining high resolution monitoring and catchment scale physical based modelling, further process studies and creation of early warning systems, for example to optimization of drinking water uptake from rivers, can be achieved.

  4. High Resolution ground penetrating radar (GPR) measurements at the laboratory scale to model porosity and permeability in the Miami Limestone in South Florida.

    NASA Astrophysics Data System (ADS)

    Mount, G. J.; Comas, X.

    2015-12-01

    Subsurface water flow within the Biscayne aquifer is controlled by the heterogeneous distribution of porosity and permeability in the karst Miami Limestone and the presence of numerous dissolution and mega-porous features. The dissolution features and other high porosity areas can create preferential flow paths and direct recharge to the aquifer, which may not be accurately conceptualized in groundwater flow models. As hydrologic conditions are undergoing restoration in the Everglades, understanding the distribution of these high porosity areas within the subsurface would create a better understanding of subsurface flow. This research utilizes ground penetrating radar to estimate the spatial variability of porosity and dielectric permittivity of the Miami Limestone at centimeter scale resolution at the laboratory scale. High frequency GPR antennas were used to measure changes in electromagnetic wave velocity through limestone samples under varying volumetric water contents. The Complex Refractive Index Model (CRIM) was then applied in order to estimate porosity and dielectric permittivity of the solid phase of the limestone. Porosity estimates ranged from 45.2-66.0% from the CRIM model and correspond well with estimates of porosity from analytical and digital image techniques. Dielectric permittivity values of the limestone solid phase ranged from 7.0 and 13.0, which are similar to values in the literature. This research demonstrates the ability of GPR to identify the cm scale spatial variability of aquifer properties that influence subsurface water flow which could have implications for groundwater flow models in the Biscayne and potentially other shallow karst aquifers.

  5. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; in-bottle acid digestion of whole-water samples

    USGS Publications Warehouse

    Hoffman, G.L.; Fishman, M. J.; Garbarino, J.R.

    1996-01-01

    Water samples for trace-metal determinations routinely have been prepared in open laboratories. For example, the U.S. Geological Survey method I-3485-85 (Extraction Procedure, for Water- Suspended Sediment) is performed in a laboratory hood on a laboratory bench without any special precautions to control airborne contamination. This method tends to be contamination prone for several trace metals primarily because the samples are transferred, acidified, digested, and filtered in an open laboratory environment. To reduce trace-metal contamination of digested water samples, procedures were established that rely on minimizing sample-transfer steps and using a class-100 clean bench during sample filtration. This new procedure involves the following steps: 1. The sample is acidified with HCl directly in the original water-sample bottle. 2. The water-sample bottle with the cap secured is heated in a laboratory oven. 3. The digestate is filtered in a class-100 laminar-flow clean bench. The exact conditions used (that is, oven temperature, time of heating, and filtration methods) for this digestion procedure are described. Comparisons between the previous U.S Geological Survey open-beaker method I-3485-85 and the new in-bottle procedure for synthetic and field-collected water samples are given. When the new procedure is used, blank concentrations for most trace metals determined are reduced significantly.

  6. CALIBRATION OF FULL-SCALE OZONATION SYSTEMS WITH CONSERVATIVE AND REACTIVE TRACERS

    EPA Science Inventory

    A full-scale ozonation reactor was characterized with respect to the overall oxidation budget by coupling laboratory kinetics with reactor hydraulics. The ozone decomposition kinetics and the ratio of the OH radical to the ozone concentration were determined in laboratory batch ...

  7. Interlaboratory comparability, bias, and precision for four laboratories measuring constituents in precipitation, November 1982-August 1983

    USGS Publications Warehouse

    Brooks, M.H.; Schroder, L.J.; Malo, B.A.

    1985-01-01

    Four laboratories were evaluated in their analysis of identical natural and simulated precipitation water samples. Interlaboratory comparability was evaluated using analysis of variance coupled with Duncan 's multiple range test, and linear-regression models describing the relations between individual laboratory analytical results for natural precipitation samples. Results of the statistical analyses indicate that certain pairs of laboratories produce different results when analyzing identical samples. Analyte bias for each laboratory was examined using analysis of variance coupled with Duncan 's multiple range test on data produced by the laboratories from the analysis of identical simulated precipitation samples. Bias for a given analyte produced by a single laboratory has been indicated when the laboratory mean for that analyte is shown to be significantly different from the mean for the most-probable analyte concentrations in the simulated precipitation samples. Ion-chromatographic methods for the determination of chloride, nitrate, and sulfate have been compared with the colorimetric methods that were also in use during the study period. Comparisons were made using analysis of variance coupled with Duncan 's multiple range test for means produced by the two methods. Analyte precision for each laboratory has been estimated by calculating a pooled variance for each analyte. Analyte estimated precisions have been compared using F-tests and differences in analyte precisions for laboratory pairs have been reported. (USGS)

  8. First European interlaboratory comparison of tetracycline and age determination with red fox teeth following oral rabies vaccination programs.

    PubMed

    Robardet, Emmanuelle; Demerson, Jean-Michel; Andrieu, Sabrina; Cliquet, Florence

    2012-10-01

    The first European interlaboratory comparison of tetracycline and age determination with red fox (Vulpes vulpes) tooth samples was organized by the European Union Reference Laboratory for rabies. Performance and procedures implemented by member states were compared. These techniques are widely used to monitor bait uptake in European oral rabies vaccination campaigns. A panel of five red fox half-mandibles comprising one weak positive juvenile sample, two positive adult samples, one negative juvenile sample, and one negative adult sample were sent, along with a technical questionnaire, to 12 laboratories participating on a voluntary basis. The results of only three laboratories (25%) were 100% correct. False-negative results were more frequently seen in weak positive juvenile samples (58%) but were infrequent in positive adult samples (4%), probably due to differences in the ease of reading the two groups of teeth. Four laboratories (44%) had correct results for age determination on all samples. Ages were incorrectly identified in both adult and juvenile samples, with 11 and 17% of discordant results, respectively. Analysis of the technical questionnaires in parallel with test results suggested that all laboratories cutting mandible sections between the canine and first premolar obtained false results. All the laboratories using longitudinal rather than transverse sections and those not using a mounting medium also produced false results. Section thickness appeared to affect the results; no mistakes were found in laboratories using sections <150 μm thick. Factors having a potential impact on the success of laboratories were discussed, and recommendations proposed. Such interlaboratory trials underline the importance of using standardized procedures for biomarker detection in oral rabies vaccination campaigns. Several changes can be made to improve analysis quality and increase the comparability of bait uptake frequencies among member states.

  9. Interlaboratory comparison for the determination of the soluble fraction of metals in welding fume samples.

    PubMed

    Berlinger, Balazs; Harper, Martin

    2018-02-01

    There is interest in the bioaccessible metal components of aerosols, but this has been minimally studied because standardized sampling and analytical methods have not yet been developed. An interlaboratory study (ILS) has been carried out to evaluate a method for determining the water-soluble component of realistic welding fume (WF) air samples. Replicate samples were generated in the laboratory and distributed to participating laboratories to be analyzed according to a standardized procedure. Within-laboratory precision of replicate sample analysis (repeatability) was very good. Reproducibility between laboratories was not as good, but within limits of acceptability for the analysis of typical aerosol samples. These results can be used to support the development of a standardized test method.

  10. Automatic scoring of dicentric chromosomes as a tool in large scale radiation accidents.

    PubMed

    Romm, H; Ainsbury, E; Barnard, S; Barrios, L; Barquinero, J F; Beinke, C; Deperas, M; Gregoire, E; Koivistoinen, A; Lindholm, C; Moquet, J; Oestreicher, U; Puig, R; Rothkamm, K; Sommer, S; Thierens, H; Vandersickel, V; Vral, A; Wojcik, A

    2013-08-30

    Mass casualty scenarios of radiation exposure require high throughput biological dosimetry techniques for population triage in order to rapidly identify individuals who require clinical treatment. The manual dicentric assay is a highly suitable technique, but it is also very time consuming and requires well trained scorers. In the framework of the MULTIBIODOSE EU FP7 project, semi-automated dicentric scoring has been established in six European biodosimetry laboratories. Whole blood was irradiated with a Co-60 gamma source resulting in 8 different doses between 0 and 4.5Gy and then shipped to the six participating laboratories. To investigate two different scoring strategies, cell cultures were set up with short term (2-3h) or long term (24h) colcemid treatment. Three classifiers for automatic dicentric detection were applied, two of which were developed specifically for these two different culture techniques. The automation procedure included metaphase finding, capture of cells at high resolution and detection of dicentric candidates. The automatically detected dicentric candidates were then evaluated by a trained human scorer, which led to the term 'semi-automated' being applied to the analysis. The six participating laboratories established at least one semi-automated calibration curve each, using the appropriate classifier for their colcemid treatment time. There was no significant difference between the calibration curves established, regardless of the classifier used. The ratio of false positive to true positive dicentric candidates was dose dependent. The total staff effort required for analysing 150 metaphases using the semi-automated approach was 2 min as opposed to 60 min for manual scoring of 50 metaphases. Semi-automated dicentric scoring is a useful tool in a large scale radiation accident as it enables high throughput screening of samples for fast triage of potentially exposed individuals. Furthermore, the results from the participating laboratories were comparable which supports networking between laboratories for this assay. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Field Exploration and Life Detection Sampling for Planetary Analogue Research (FELDSPAR)

    NASA Astrophysics Data System (ADS)

    Gentry, D.; Stockton, A. M.; Amador, E. S.; Cable, M. L.; Cantrell, T.; Chaudry, N.; Cullen, T.; Duca, Z. A.; Jacobsen, M. B.; Kirby, J.; McCaig, H. C.; Murukesan, G.; Rennie, V.; Rader, E.; Schwieterman, E. W.; Stevens, A. H.; Sutton, S. A.; Tan, G.; Yin, C.; Cullen, D.; Geppert, W.

    2017-12-01

    Extraterrestrial studies are typically conducted on mg samples from cm-scale features, while landing sites are selected based on m to km-scale features. It is therefore critical to understand spatial distribution of organic molecules over scales from cm to the km, particularly in geological features that appear homogenous at m to km scales. This is addressed by FELDSPAR, a NASA-funded project that conducts field operations analogous to Mars sample return in its science, operations, and technology [1]. Here, we present recent findings from a 2016 and a 2017 campaign to multiple Martian analogue sites in Iceland. Icelandic volcanic regions are Mars analogues due to desiccation, low nutrient availability, temperature extremes [2], and are relatively young and isolated from anthropogenic contamination [3]. Operationally, many Icelandic analogue sites are remote enough to require that field expeditions address several sampling constraints that are also faced by robotic exploration [1, 2]. Four field sites were evaluated in this study. The Fimmvörðuháls lava field was formed by a basaltic effusive eruption associated with the 2010 Eyjafjallajökull eruption. Mælifellssandur is a recently deglaciated plain to the north of the Myrdalsjökull glacier. Holuhraun is a basaltic spatter and cinder cone formed by 2014 fissure eruptions just north of the Vatnajökull glacier. Dyngjusandur is a plain kept barren by repeated aeolian mechanical weathering. Samples were collected in nested triangular grids from 10 cm to the 1 km scale. We obtained overhead imagery at 1 m to 200 m elevation to create digital elevation models. In-field reflectance spectroscopy was obtained with an ASD spectrometer and chemical composition was measured by a Bruker handheld XRF. All sites chosen were homogeneous in apparent color, morphology, moisture, grain size, and reflectance spectra at all scales greater than 10 cm. Field lab ATP assays were conducted to monitor microbial habitation, and home laboratory analyses include qPCR, Raman spectroscopy and community sequencing. For more information, find us on Facebook @FELDSPAResearch. [1] Amador, E. S. et al. (2015) Planet. Space Sci., 106 1-10. [2] Cockell, C. S. et al., (2011) Astrobio., 11 679-694; Gentry, et al., (2017) Astrobio., in press. [3] Bagshaw, E. A. et al., (2011) Astrobio., 11 651-664.

  12. Quality-assurance results for routine water analyses in U.S. Geological Survey laboratories, water year 1998

    USGS Publications Warehouse

    Ludtke, Amy S.; Woodworth, Mark T.; Marsh, Philip S.

    2000-01-01

    The U.S. Geological Survey operates a quality-assurance program based on the analyses of reference samples for two laboratories: the National Water Quality Laboratory and the Quality of Water Service Unit. Reference samples that contain selected inorganic, nutrient, and low-level constituents are prepared and submitted to the laboratory as disguised routine samples. The program goal is to estimate precision and bias for as many analytical methods offered by the participating laboratories as possible. Blind reference samples typically are submitted at a rate of 2 to 5 percent of the annual environmental-sample load for each constituent. The samples are distributed to the laboratories throughout the year. The reference samples are subject to the identical laboratory handling, processing, and analytical procedures as those applied to environmental samples and, therefore, have been used as an independent source to verify bias and precision of laboratory analytical methods and ambient water-quality measurements. The results are stored permanently in the National Water Information System and the Blind Sample Project's data base. During water year 1998, 95 analytical procedures were evaluated at the National Water Quality Laboratory and 63 analytical procedures were evaluated at the Quality of Water Service Unit. An overall evaluation of the inorganic and low-level constituent data for water year 1998 indicated 77 of 78 analytical procedures at the National Water Quality Laboratory met the criteria for precision. Silver (dissolved, inductively coupled plasma-mass spectrometry) was determined to be imprecise. Five of 78 analytical procedures showed bias throughout the range of reference samples: chromium (dissolved, inductively coupled plasma-atomic emission spectrometry), dissolved solids (dissolved, gravimetric), lithium (dissolved, inductively coupled plasma-atomic emission spectrometry), silver (dissolved, inductively coupled plasma-mass spectrometry), and zinc (dissolved, inductively coupled plasma-mass spectrometry). At the National Water Quality Laboratory during water year 1998, lack of precision was indicated for 2 of 17 nutrient procedures: ammonia as nitrogen (dissolved, colorimetric) and orthophosphate as phosphorus (dissolved, colorimetric). Bias was indicated throughout the reference sample range for ammonia as nitrogen (dissolved, colorimetric, low level) and nitrate plus nitrite as nitrogen (dissolved, colorimetric, low level). All analytical procedures tested at the Quality of Water Service Unit during water year 1998 met the criteria for precision. One of the 63 analytical procedures indicated a bias throughout the range of reference samples: aluminum (whole-water recoverable, inductively coupled plasma-atomic emission spectrometry, trace).

  13. A round robin approach to the analysis of bisphenol a (BPA) in human blood samples

    PubMed Central

    2014-01-01

    Background Human exposure to bisphenol A (BPA) is ubiquitous, yet there are concerns about whether BPA can be measured in human blood. This Round Robin was designed to address this concern through three goals: 1) to identify collection materials, reagents and detection apparatuses that do not contribute BPA to serum; 2) to identify sensitive and precise methods to accurately measure unconjugated BPA (uBPA) and BPA-glucuronide (BPA-G), a metabolite, in serum; and 3) to evaluate whether inadvertent hydrolysis of BPA-G occurs during sample handling and processing. Methods Four laboratories participated in this Round Robin. Laboratories screened materials to identify BPA contamination in collection and analysis materials. Serum was spiked with concentrations of uBPA and/or BPA-G ranging from 0.09-19.5 (uBPA) and 0.5-32 (BPA-G) ng/mL. Additional samples were preserved unspiked as ‘environmental’ samples. Blinded samples were provided to laboratories that used LC/MSMS to simultaneously quantify uBPA and BPA-G. To determine whether inadvertent hydrolysis of BPA metabolites occurred, samples spiked with only BPA-G were analyzed for the presence of uBPA. Finally, three laboratories compared direct and indirect methods of quantifying BPA-G. Results We identified collection materials and reagents that did not introduce BPA contamination. In the blinded spiked sample analysis, all laboratories were able to distinguish low from high values of uBPA and BPA-G, for the whole spiked sample range and for those samples spiked with the three lowest concentrations (0.5-3.1 ng/ml). By completion of the Round Robin, three laboratories had verified methods for the analysis of uBPA and two verified for the analysis of BPA-G (verification determined by: 4 of 5 samples within 20% of spiked concentrations). In the analysis of BPA-G only spiked samples, all laboratories reported BPA-G was the majority of BPA detected (92.2 – 100%). Finally, laboratories were more likely to be verified using direct methods than indirect ones using enzymatic hydrolysis. Conclusions Sensitive and accurate methods for the direct quantification of uBPA and BPA-G were developed in multiple laboratories and can be used for the analysis of human serum samples. BPA contamination can be controlled during sample collection and inadvertent hydrolysis of BPA conjugates can be avoided during sample handling. PMID:24690217

  14. Visualisation and Quantification of Transport in Barrier Rocks with Positron Emission Tomography

    NASA Astrophysics Data System (ADS)

    Kulenkampff, J.; Gajewski, C.; Gründig, M.; Lippmann-Pipke, J.; Mittmann, H.; Richter, M.; Wolf, M.

    2009-04-01

    In tight barrier rocks laboratory observation of radionuclide transport and determination of transport parameters is a demanding and interminable task, because of slow rates, small concentrations, and intricate chemical interactions. The validity of results from common laboratory methods, like flow- and diffusion experiments on small samples, is limited by the heterogeneity of the pathways and adherent upscaling issues, because homogeneous conditions have to be presumed for these input-output investigations. But nano-pores or micro-fractures could be present, which would provide pathways for heterogeneous transport processes. Transport properties of these pathways are most influential boundary conditions for reactions between fluid components and crystal surfaces. We propose Positron Emission Tomography (GEO-PET) as an appropriate method for direct observation of heterogeneous transport of radiotracers in tight material on the laboratory scale. With high-resolution PET scanners, which are common instruments of biomedical research ("small animal PET"), it is possible to determine the spatio-temporal distribution of the tracer activity with a resolution of almost 1 mm during about three periods of the tracer half-life (half-lives of some applicable PET tracers: 18F: 1.8 h, 124I: 4.2 days, 58Co: 70.8 days). The PET tracer is applied as ion in solution or as marker for compounds, like colloids. The most considerable difference between PET applications on geomaterial compared to biological tissue is the stronger attenuation and scattering of radiation because of the higher density of rock material. After travelling the positron attenuation length in dense material (about 1 mm), the positron annihilates in contact with an electron, transmitting two photons with 511 keV, propagating in antiparallel direction. The sample size of geomaterial is limited by the attenuation length of these photons. By applying an appropriate attenuation correction it is possible to investigate transport processes in rock cores with diameters up to 10 cm. Then at least 20% of the initial annihilation events are recorded as coincidences. However, one single photon of the annihilation radiation may be recorded while the other is absorbed; therefore, the signal to noise ratio is degraded by attenuation. Other sources of noise are scattered events, and the loss of one coinciding photon due to gaps between the detectors and other detection probability reasons. Also, the ratio of random coincidences increases with the noise level and impairs the image quality of the tomographic reconstruction. The reduction of these reconstruction artefacts by enhanced data correction methods is an important requirement for the development of the GEO-PET method. An other problem is the development of special methods for the quantitative evaluation of the extensive spatio-temporal data sets. We present results from high-resolution PET for tomographic process observation during transport of colloids and conservative tracers in macroscopic samples of clays, saline rocks, and granites (diameter 5 to 10 cm, length 5 to 20 cm). In most cases we observed localized zones of transport, even in a homogenized compressed clay sample. This reflects the non-representative sample volume, which probably is not achievable for any laboratory method. However, at least the PET tomograms reveal these deviations from representativeness. Up to now, break-through-curve parameters can be determined from spatially resolved tracer concentration measurements at distinct regions of the sample, without mandatory penetration of the complete sample extension. A multiscale model-based inversion scheme for continuous scale-dependent parameter determination is currently developed.

  15. Parameterization and sensitivity analyses of a radiative transfer model for remote sensing plant canopies

    NASA Astrophysics Data System (ADS)

    Hall, Carlton Raden

    A major objective of remote sensing is determination of biochemical and biophysical characteristics of plant canopies utilizing high spectral resolution sensors. Canopy reflectance signatures are dependent on absorption and scattering processes of the leaf, canopy properties, and the ground beneath the canopy. This research investigates, through field and laboratory data collection, and computer model parameterization and simulations, the relationships between leaf optical properties, canopy biophysical features, and the nadir viewed above-canopy reflectance signature. Emphasis is placed on parameterization and application of an existing irradiance radiative transfer model developed for aquatic systems. Data and model analyses provide knowledge on the relative importance of leaves and canopy biophysical features in estimating the diffuse absorption a(lambda,m-1), diffuse backscatter b(lambda,m-1), beam attenuation alpha(lambda,m-1), and beam to diffuse conversion c(lambda,m-1 ) coefficients of the two-flow irradiance model. Data sets include field and laboratory measurements from three plant species, live oak (Quercus virginiana), Brazilian pepper (Schinus terebinthifolius) and grapefruit (Citrus paradisi) sampled on Cape Canaveral Air Force Station and Kennedy Space Center Florida in March and April of 1997. Features measured were depth h (m), projected foliage coverage PFC, leaf area index LAI, and zenith leaf angle. Optical measurements, collected with a Spectron SE 590 high sensitivity narrow bandwidth spectrograph, included above canopy reflectance, internal canopy transmittance and reflectance and bottom reflectance. Leaf samples were returned to laboratory where optical and physical and chemical measurements of leaf thickness, leaf area, leaf moisture and pigment content were made. A new term, the leaf volume correction index LVCI was developed and demonstrated in support of model coefficient parameterization. The LVCI is based on angle adjusted leaf thickness Ltadj, LAI, and h (m). Its function is to translate leaf level estimates of diffuse absorption and backscatter to the canopy scale allowing the leaf optical properties to directly influence above canopy estimates of reflectance. The model was successfully modified and parameterized to operate in a canopy scale and a leaf scale mode. Canopy scale model simulations produced the best results. Simulations based on leaf derived coefficients produced calculated above canopy reflectance errors of 15% to 18%. A comprehensive sensitivity analyses indicated the most important parameters were beam to diffuse conversion c(lambda, m-1), diffuse absorption a(lambda, m-1), diffuse backscatter b(lambda, m-1), h (m), Q, and direct and diffuse irradiance. Sources of error include the estimation procedure for the direct beam to diffuse conversion and attenuation coefficients and other field and laboratory measurement and analysis errors. Applications of the model include creation of synthetic reflectance data sets for remote sensing algorithm development, simulations of stress and drought on vegetation reflectance signatures, and the potential to estimate leaf moisture and chemical status.

  16. Pilot-scale production of fuel ethanol from concentrated food waste hydrolysates using Saccharomyces cerevisiae H058.

    PubMed

    Yan, Shoubao; Chen, Xiangsong; Wu, Jingyong; Wang, Pingchao

    2013-07-01

    The aim of this study was to develop a bioprocess to produce ethanol from food waste at laboratory, semipilot and pilot scales. Laboratory tests demonstrated that ethanol fermentation with reducing sugar concentration of 200 g/L, inoculum size of 2 % (Initial cell number was 2 × 10⁶ CFU/mL) and addition of YEP (3 g/L of yeast extract and 5 g/L of peptone) was the best choice. The maximum ethanol concentration in laboratory scale (93.86 ± 1.15 g/L) was in satisfactory with semipilot scale (93.79 ± 1.11 g/L), but lower than that (96.46 ± 1.12 g/L) of pilot-scale. Similar ethanol yield and volumetric ethanol productivity of 0.47 ± 0.02 g/g, 1.56 ± 0.03 g/L/h and 0.47 ± 0.03 g/g, 1.56 ± 0.03 g/L/h after 60 h of fermentation in laboratory and semipilot fermentors, respectively, however, both were lower than that (0.48 ± 0.02 g/g, 1.79 ± 0.03 g/L/h) of pilot reactor. In addition, simple models were developed to predict the fermentation kinetics during the scale-up process and they were successfully applied to simulate experimental results.

  17. Predicting the performance uncertainty of a 1-MW pilot-scale carbon capture system after hierarchical laboratory-scale calibration and validation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Zhijie; Lai, Canhai; Marcy, Peter William

    2017-05-01

    A challenging problem in designing pilot-scale carbon capture systems is to predict, with uncertainty, the adsorber performance and capture efficiency under various operating conditions where no direct experimental data exist. Motivated by this challenge, we previously proposed a hierarchical framework in which relevant parameters of physical models were sequentially calibrated from different laboratory-scale carbon capture unit (C2U) experiments. Specifically, three models of increasing complexity were identified based on the fundamental physical and chemical processes of the sorbent-based carbon capture technology. Results from the corresponding laboratory experiments were used to statistically calibrate the physical model parameters while quantifying some of theirmore » inherent uncertainty. The parameter distributions obtained from laboratory-scale C2U calibration runs are used in this study to facilitate prediction at a larger scale where no corresponding experimental results are available. In this paper, we first describe the multiphase reactive flow model for a sorbent-based 1-MW carbon capture system then analyze results from an ensemble of simulations with the upscaled model. The simulation results are used to quantify uncertainty regarding the design’s predicted efficiency in carbon capture. In particular, we determine the minimum gas flow rate necessary to achieve 90% capture efficiency with 95% confidence.« less

  18. Stable isotope quality assurance using the 'calibrated IRMS' strategy.

    PubMed

    Meijer, Harro A J

    2009-06-01

    Procedures in our laboratory have always been directed towards complete understanding of all processes involved and corrections needed etc., instead of relying fully on laboratory reference materials. This rather principal strategy (or attitude) is probably not optimal in the economic sense, and is not necessarily more accurate either. Still, it has proven to be very rewarding in its capability to detect caveats that go undiscovered in the standard way of measurement, but that do influence the accuracy or reliability of the measurement procedure. An additional benefit of our laboratory procedures is that it makes us capable of assisting the International Atomic Energy Agency (IAEA) with primary questions like mutual scale assignments and comparison of isotope ratios of the same isotope in different matrices (like delta(18)O in water, carbonates and atmospheric CO(2)), establishment of the (17)O-(18)O relation, and the replenishment of the calibration standards. Finally, for manual preparation systems with a low sample throughput (and thus only few reference materials analysed) it may well be the only way to produce reliable results.

  19. Scaling similarities of multiple fracturing of solid materials

    NASA Astrophysics Data System (ADS)

    Kapiris, P. G.; Balasis, G. T.; Kopanas, J. A.; Antonopoulos, G. N.; Peratzakis, A. S.; Eftaxias, K. A.

    2004-02-01

    It has recently reported that electromagnetic flashes of low-energy gamma-rays emitted during multi-fracturing on a neutron star, and electromagnetic pulses emitted in the laboratory by a disordered material subjected to an increasing external load, share distinctive statistical properties with earthquakes, such as power-law energy distributions (Cheng et al., 1996; Kossobokov et al., 2000; Rabinovitch et al., 2001; Sornette and Helmstetter, 2002). The neutron starquakes may release strain energies up to 1046 erg, while, the fractures in laboratory samples release strain energies approximately a fraction of an erg. An earthquake fault region can build up strain energy up to approximately 1026 erg for the strongest earthquakes. Clear sequences of kilohertz-megahertz electromagnetic avalanches have been detected from a few days up to a few hours prior to recent destructive earthquakes in Greece. A question that arises effortlessly is if the pre-seismic electromagnetic fluctuations also share the same statistical properties. Our study justifies a positive answer. Our analysis also reveals "symptoms" of a transition to the main rupture common with earthquake sequences and acoustic emission pulses observed during laboratory experiments (Maes et al., 1998).

  20. Factors controlling the regional distribution of vanadium in ground water

    USGS Publications Warehouse

    Wright, Michael T.; Belitz, Kenneth

    2010-01-01

    Although the ingestion of vanadium (V) in drinking water may have possible adverse health effects, there have been relatively few studies of V in groundwater. Given the importance of groundwater as a source of drinking water in many areas of the world, this study examines the potential sources and geochemical processes that control the distribution of V in groundwater on a regional scale. Potential sources of V to groundwater include dissolution of V rich rocks, and waste streams from industrial processes. Geochemical processes such as adsorption/desorption, precipitation/dissolution, and chemical transformations control V concentrations in groundwater. Based on thermodynamic data and laboratory studies, V concentrations are expected to be highest in samples collected from oxic and alkaline groundwater. However, the extent to which thermodynamic data and laboratory results apply to the actual distribution of V in groundwater is not well understood. More than 8400 groundwater samples collected in California were used in this study. Of these samples, high (> or = 50 μg/L) and moderate (25 to 49 μg/L) V concentrations were most frequently detected in regions where both source rock and favorable geochemical conditions occurred. The distribution of V concentrations in groundwater samples suggests that significant sources of V are mafic and andesitic rock. Anthropogenic activities do not appear to be a significant contributor of V to groundwater in this study. High V concentrations in groundwater samples analyzed in this study were almost always associated with oxic and alkaline groundwater conditions, which is consistent with predictions based on thermodynamic data.

  1. Lessons from Astrobiological Planetary Analogue Exploration in Iceland: Biomarker Assay Performance and Downselection

    NASA Technical Reports Server (NTRS)

    Gentry, D. M.; Amador, E. S.; Cable, M. L.; Cantrell, T.; Chaudry, N.; Cullen, T.; Duca, Z.; Kirby, J.; Jacobsen, M.; McCaig, H.; hide

    2017-01-01

    Understanding the sensitivity of biomarker assays to the local physicochemical environment, and the underlying spatial distribution of the target biomarkers in 'homogeneous' environments, can increase mission science return. We have conducted four expeditions to Icelandic Mars analogue sites in which an increasingly refined battery of physicochemical measurements and biomarker assays were performed, staggered with scouting of further sites. Completed expeditions took place in 2012 (location scouting and field assay use testing), 2013 (sampling of two major sites with three assays and observational physicochemical measurements), 2015 (repeat sampling of prior sites and one new site, scouting of new sites, three assays and three instruments), and 2016 (preliminary sampling of new sites with analysis of returned samples). Target sites were geologically recent basaltic lava flows, and sample loci were arranged in hierarchically nested grids at 10 cm, 1 m, 10 m, 100 m, and >1 km order scales, subject to field constraints. Assays were intended to represent a diversity of potential biomarker types (cell counting via nucleic acid staining and fluorescence microscopy, ATP quantification via luciferase luminescence, and relative DNA quantification with simple domain-level primers) rather a specific mission science target, and were selected to reduce laboratory overhead, require limited consumables, and allow rapid turnaround. All analytical work was performed in situ or in a field laboratory within a day's travel of the field sites unless otherwise noted. We have demonstrated the feasibility of performing ATP quantification and qPCR analysis in a field-based laboratory with single-day turnaround. The ATP assay was generally robust and reliable and required minimal field equipment and training to produce a large amount of useful data. DNA was successfully extracted from all samples, but the serial-batch nature of qPCR significantly limited the number of primers (hence classifications) and replicates that could be run in a single day. Fluorescence microscopy did not prove feasible under the same constraints, primarily due to the large number of person-hours required to view, analyze, and record results from the images; however, this could be mitigated with higher-quality imaging instruments and appropriate image analysis software.

  2. SIMILARITY PROPERTIES AND SCALING LAWS OF RADIATION HYDRODYNAMIC FLOWS IN LABORATORY ASTROPHYSICS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Falize, E.; Bouquet, S.; Michaut, C., E-mail: emeric.falize@cea.fr

    The spectacular recent development of modern high-energy density laboratory facilities which concentrate more and more energy in millimetric volumes allows the astrophysical community to reproduce and to explore, in millimeter-scale targets and during very short times, astrophysical phenomena where radiation and matter are strongly coupled. The astrophysical relevance of these experiments can be checked from the similarity properties and especially scaling law establishment, which constitutes the keystone of laboratory astrophysics. From the radiating optically thin regime to the so-called optically thick radiative pressure regime, we present in this paper, for the first time, a complete analysis of the main radiatingmore » regimes that we encountered in laboratory astrophysics with the same formalism based on Lie group theory. The use of the Lie group method appears to be a systematic method which allows us to construct easily and systematically the scaling laws of a given problem. This powerful tool permits us to unify the recent major advances on scaling laws and to identify new similarity concepts that we discuss in this paper, and suggests important applications for present and future laboratory astrophysics experiments. All these results enable us to demonstrate theoretically that astrophysical phenomena in such radiating regimes can be explored experimentally thanks to powerful facilities. Consequently, the results presented here are a fundamental tool for the high-energy density laboratory astrophysics community in order to quantify the astrophysics relevance and justify laser experiments. Moreover, relying on Lie group theory, this paper constitutes the starting point of any analysis of the self-similar dynamics of radiating fluids.« less

  3. Strain partitioning in shales during elastic and creep deformation observed by synchrotron X-ray micro-tomography.

    NASA Astrophysics Data System (ADS)

    Sone, H.; Cheung, C.; Rivers, M. L.; Wang, Y.; Yu, T.

    2016-12-01

    Knowledge about the ductile time-dependent constitutive behavior of geological materials is essential when evaluating the long-term integrity of subsurface structures and predicting the long-term geomechanical response of the surrounding formations. To this end, it is not only important to measure the bulk time-dependent behavior but also essential to understand the microscale mechanism by which rocks exhibit time-dependence, because laboratory data needs to be extrapolated to time-scales much beyond laboratory experiments. We conducted long-term creep experiments using Green River shale samples and obtained synchrotron X-ray images during the tests in an attempt to capture the microscale strain-partitioning that occurs within the sample. Shale samples of few millimeter dimensions were stressed up to several tens of MPa by a spring-loaded device within an X-ray transparent load frame, and the load was held constant for up to several months to allow creep deformation. Tomographic images of about 5 micron resolution were reconstructed from images collected at different timings of the experiment, which allows us to investigate where and how much strain localized during elastic and creep deformation. Tracking the position of some outstanding features in the rock texture (e.g. pyrite grains, organic material patches) indicate that strain magnitudes expected from the sample elastic and relaxation modulus can be successfully recovered from the tomographic images. We also attempt to use digital volume correlation to track sub-voxel displacements and to characterize the spatial heterogeneity of the deformation.

  4. Capillary blood sampling: national recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine

    PubMed Central

    Krleza, Jasna Lenicek; Dorotic, Adrijana; Grzunov, Ana; Maradin, Miljenka

    2015-01-01

    Capillary blood sampling is a medical procedure aimed at assisting in patient diagnosis, management and treatment, and is increasingly used worldwide, in part because of the increasing availability of point-of-care testing. It is also frequently used to obtain small blood volumes for laboratory testing because it minimizes pain. The capillary blood sampling procedure can influence the quality of the sample as well as the accuracy of test results, highlighting the need for immediate, widespread standardization. A recent nationwide survey of policies and practices related to capillary blood sampling in medical laboratories in Croatia has shown that capillary sampling procedures are not standardized and that only a small proportion of Croatian laboratories comply with guidelines from the Clinical Laboratory Standards Institute (CLSI) or the World Health Organization (WHO). The aim of this document is to provide recommendations for capillary blood sampling. This document has been produced by the Working Group for Capillary Blood Sampling within the Croatian Society of Medical Biochemistry and Laboratory Medicine. Our recommendations are based on existing available standards and recommendations (WHO Best Practices in Phlebotomy, CLSI GP42-A6 and CLSI C46-A2), which have been modified based on local logistical, cultural, legal and regulatory requirements. We hope that these recommendations will be a useful contribution to the standardization of capillary blood sampling in Croatia. PMID:26524965

  5. Capillary blood sampling: national recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    PubMed

    Krleza, Jasna Lenicek; Dorotic, Adrijana; Grzunov, Ana; Maradin, Miljenka

    2015-01-01

    Capillary blood sampling is a medical procedure aimed at assisting in patient diagnosis, management and treatment, and is increasingly used worldwide, in part because of the increasing availability of point-of-care testing. It is also frequently used to obtain small blood volumes for laboratory testing because it minimizes pain. The capillary blood sampling procedure can influence the quality of the sample as well as the accuracy of test results, highlighting the need for immediate, widespread standardization. A recent nationwide survey of policies and practices related to capillary blood sampling in medical laboratories in Croatia has shown that capillary sampling procedures are not standardized and that only a small proportion of Croatian laboratories comply with guidelines from the Clinical Laboratory Standards Institute (CLSI) or the World Health Organization (WHO). The aim of this document is to provide recommendations for capillary blood sampling. This document has been produced by the Working Group for Capillary Blood Sampling within the Croatian Society of Medical Biochemistry and Laboratory Medicine. Our recommendations are based on existing available standards and recommendations (WHO Best Practices in Phlebotomy, CLSI GP42-A6 and CLSI C46-A2), which have been modified based on local logistical, cultural, legal and regulatory requirements. We hope that these recommendations will be a useful contribution to the standardization of capillary blood sampling in Croatia.

  6. [CO2 Budget and Atmospheric Rectification (COBRA) Over North America

    NASA Technical Reports Server (NTRS)

    2004-01-01

    The purpose of the CO2 Budget and Rectification Airborne (COBRA) study was to assess terrestrial sources and sinks of carbon dioxide using an air-borne study. The study was designed to address the measurement gap between plot-scale direct flux measurements and background hemispheric-scale constraints and to refine techniques for measuring terrestrial fluxes at regional to continental scales. The initial funded effort (reported on here) was to involve two air-borne campaigns over North America, one in summer and one in winter. Measurements for COBRA (given the acronym C02BAR in the initial proposal) were conducted from the University of North Dakota Citation 11, a twin-engine jet aircraft capable of profiling from the surface to 12 km and cruising for up to 4 hours and 175m/s. Onboard instrumentation measured concentrations of CO2, CO, and H2O, and meteorological parameters at high rates. In addition, two separate flask sampling systems collected discrete samples for laboratory analysis of CO2,CO, CH4, N2O, SF6, H2, 13CO2, C18O16O,O2/N2, and Ar/N2. The project involved a collaboration between a number of institutions, including (but not limited to) Harvard, NOAA-CMDL, the University of North Dakota, and Scripps.

  7. Order parameter aided efficient phase space exploration under extreme conditions

    NASA Astrophysics Data System (ADS)

    Samanta, Amit

    Physical processes in nature exhibit disparate time-scales, for example time scales associated with processes like phase transitions, various manifestations of creep, sintering of particles etc. are often much higher than time the system spends in the metastable states. The transition times associated with such events are also orders of magnitude higher than time-scales associated with vibration of atoms. Thus, an atomistic simulation of such transition events is a challenging task. Consequently, efficient exploration of configuration space and identification of metastable structures in condensed phase systems is challenging. In this talk I will illustrate how we can define a set of coarse-grained variables or order parameters and use these to systematically and efficiently steer a system containing thousands or millions of atoms over different parts of the configuration. This order parameter aided sampling can be used to identify metastable states, transition pathways and understand the mechanistic details of complex transition processes. I will illustrate how this sampling scheme can be used to study phase transition pathways and phase boundaries in prototypical materials, like SiO2 and Cu under high-pressure conditions. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  8. The effect of cooperative learning on the attitudes toward science and the achievement of students in a non-science majors' general biology laboratory course at an urban community college

    NASA Astrophysics Data System (ADS)

    Chung-Schickler, Genevieve C.

    The purpose of this study was to evaluate the effect of cooperative learning strategies on students' attitudes toward science and achievement in BSC 1005L, a non-science majors' general biology laboratory course at an urban community college. Data were gathered on the participants' attitudes toward science and cognitive biology level pre and post treatment in BSC 1005L. Elements of the Learning Together model developed by Johnson and Johnson and the Student Team-Achievement Divisions model created by Slavin were incorporated into the experimental sections of BSC 1005L. Four sections of BSC 1005L participated in this study. Participants were enrolled in the 1998 spring (January) term. Students met weekly in a two hour laboratory session. The treatment was administered to the experimental group over a ten week period. A quasi-experimental pretest-posttest control group design was used. Students in the cooperative learning group (nsb1 = 27) were administered the Test of Science-Related Attitudes (TOSRA) and the cognitive biology test at the same time as the control group (nsb2 = 19) (at the beginning and end of the term). Statistical analyses confirmed that both groups were equivalent regarding ethnicity, gender, college grade point average and number of absences. Independent sample t-tests performed on pretest mean scores indicated no significant differences in the TOSRA scale two or biology knowledge between the cooperative learning group and the control group. The scores of TOSRA scales: one, three, four, five, six, and seven were significantly lower in the cooperative learning group. Independent sample t-tests of the mean score differences did not show any significant differences in posttest attitudes toward science or biology knowledge between the two groups. Paired t-tests did not indicate any significant differences on the TOSRA or biology knowledge within the cooperative learning group. Paired t-tests did show significant differences within the control group on TOSRA scale two and biology knowledge. ANCOVAs did not indicate any significant differences on the post mean scores of the TOSRA or biology knowledge adjusted by differences in the pretest mean scores. Analysis of the research data did not show any significant correlation between attitudes toward science and biology knowledge.

  9. Laboratory and Pilot Scale Evaluation of Coagulation, Clarification, and Filtration for Upgrading Sewage Lagoon Effluents.

    DTIC Science & Technology

    1980-08-01

    AD-AGAB 906 ARMY ENGINEER WATERWAYS EXPERIMENT STATION VICKSBURG--ETC FIG 14/2 LABORATORY AND PILOT SCALE EVALUATION OF COAGULATION, CLARIFICA -ETC U...FILTRATION FOR LWGRADING JEWAGE LAGOON EFFLUENTS~ w IL j0 ( M John ullinane, Jr., Richard A. hafer (0 Environmental Laboratory gel U. S. Army Engineer ...Shafer 9. PERFORMING ORGANIZATION NAME AND ADORESS SO. PROGRAM ELEMENT, PROJECT, TASK AREA a WORK UNIT NUMBERS U. S. Army Engineer Waterways Experiment

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, G.L.

    This data package satisfies the requirement for a format IV, final report. It is a follow-up to the 45-day safety screen report for tank AP-104. Evaporator candidate feed from tank 241-AP-104 (hereafter referred to as AP-104) was characterized for physical, inorganic, organic and radiochemical parameters by the Westinghouse Hanford Company, 222-S Laboratory, and by the Battelle Pacific Northwest National Laboratory (PNNL), Analytical Chemistry Laboratory (ACL) as directed by the Tank Sample and Analysis Plan (TSAP), References 1 through 4. Preliminary data in the form of summary analytical tables were provided to the project in advance of this final report tomore » enable early estimation of evaporator operational parameters, using the Predict modeling program. Laboratory analyses at ACL Laboratory was performed according to the TSAP. Analyses were performed at the 222-S Laboratory as defined and specified in the TSAP and the Laboratory`s Quality Assurance Plan, References 5 and 6. Any deviations from the instructions documented in the TSAP are discussed in this narrative and are supported with additional documentation. SAMPLING The TSAP, section 2, provided sampling information for waste samples collected from tank AP-104. The bottle-on-a-string method was used to collect liquid grab samples from the tank. Each glass sample bottle was amber, precleaned, and contained approximately 100 milliliters. Each bottle was closed with a teflon seal cap (or teflon septum for volatile organic analysis samples). Field blank samples were prepared by placing deionized water into sampling bottles, lowering the unclosed bottles into the riser for a period of time, retrieving them from the riser, and then closing the bottles with the same types of caps used for the tank samples. None of the samples were preserved by acidification. Upon receipt, the sample bottles destined for organic analyses were placed in a refrigerator. No attempt was made during sampling to assure the complete filling of the bottles so as to exclude all headspace. These actions were consistent with safety procedures, which attempt to limit personnel exposure to hazardous ionizing radiation.« less

  11. Short communication: Analytical method and amount of preservative added to milk samples may alter milk urea nitrogen measurements.

    PubMed

    Weeks, Holley L; Hristov, Alexander N

    2017-02-01

    Milk urea N (MUN) is used by dairy nutritionists and producers to monitor dietary protein intake and is indicative of N utilization in lactating dairy cows. Two experiments were conducted to explore discrepancies in MUN results provided by 3 milk processing laboratories using different methods. An additional experiment was conducted to evaluate the effect of 2-bromo-2-nitropropane-1, 3-diol (bronopol) on MUN analysis. In experiment 1, 10 replicates of bulk tank milk samples, collected from the Pennsylvania State University's Dairy Center over 5 consecutive days, were sent to 3 milk processing laboratories in Pennsylvania. Average MUN differed between laboratory A (14.9 ± 0.40 mg/dL; analyzed on MilkoScan 4000; Foss, Hillerød, Denmark), laboratory B (6.5 ± 0.17 mg/dL; MilkoScan FT + 6000), and laboratory C (7.4 ± 0.36 mg/dL; MilkoScan 6000). In experiment 2, milk samples were spiked with urea at 0 (7.3 to 15.0 mg/dL, depending on the laboratory analyzing the samples), 17.2, 34.2, and 51.5 mg/dL of milk. Two 35-mL samples from each urea level were sent to the 3 laboratories used in experiment 1. Average analyzed MUN was greater than predicted (calculated for each laboratory based on the control; 0 mg of added urea): for laboratory A (23.2 vs. 21.0 mg/dL), laboratory B (18.0 vs. 13.3 mg/dL), and laboratory C (20.6 vs. 15.2 mg/dL). In experiment 3, replicated milk samples were preserved with 0 to 1.35 mg of bronopol/mL of milk and submitted to one milk processing laboratory that analyzed MUN using 2 different methods. Milk samples with increasing amounts of bronopol ranged in MUN concentration from 7.7 to 11.9 mg/dL and from 9.0 to 9.3 mg/dL when analyzed on MilkoScan 4000 or CL 10 (EuroChem, Moscow, Russia), respectively. In conclusion, measured MUN concentrations varied due to analytical procedure used by milk processing laboratories and were affected by the amount of bronopol used to preserve milk sample, when milk was analyzed using a mid-infrared analyzer. Thus, it is important to maintain consistency in milk sample preservation and analysis to ensure precision of MUN results. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  12. Pearson-Readhead survey from space

    NASA Astrophysics Data System (ADS)

    Preston, R. A.; Lister, M. L.; Tingay, S. J.; Piner, B. G.; Murphy, D. W.; Jones, D. L.; Meier, D. L.; Pearson, T. J.; Readhead, A. C. S.; Hirabayashi, H.; Kobayashi, H.; Inoue, M.

    2001-01-01

    We are using the VSOP space VLBI mission to observe a complete sample of Pearson-Readhead survey sources at 4.8 GHz to determine core brightness temperatures and pc-scale jet properties. The Pearson-Readhead sample has been used for extensive ground-based VLBI survey studies, and is ideal for a VSOP survey because the sources are strong, the VSOP u-v coverages are especially good above +35o declination, and multi-epoch ground-based VLBI data and other existing supporting data exceed that of any other sample. To date we have imaged 27 of the 31 objects in our sample. Our preliminary results show that the majority of objects contain strong core components that remain unresolved on baselines of ~30,000 km. The brightness temperatures of several cores significantly exceed 1012 K, which is indicative of highly relativistically beamed emission. We discuss correlations with several other beaming indicators, such as variability and spectral index, that support this scenario. This research was performed in part at the Jet Propulsion Laboratory, California Institute of Technology, under contract to NASA.

  13. [Security Management in Clinical Laboratory Departments and Facilities: Current Status and Issues].

    PubMed

    Ishida, Haku; Nakamura, Junji; Yoshida, Hiroshi; Koike, Masaru; Inoue, Yuji

    2014-11-01

    We conducted a questionnaire survey regarding the current activities for protecting patients' privacy and the security of information systems (IS) related to the clinical laboratory departments of university hospitals, certified training facilities for clinical laboratories, and general hospitals in Yamaguchi Prefecture. The response rate was 47% from 215 medical institutions, including three commercial clinical laboratory centers. The results showed that there were some differences in management activities among facilities with respect to continuing education, the documentation or regulation of operational management for paper records, electronic information, remaining samples, genetic testing, and laboratory information for secondary use. They were suggested to be caused by differences in functions between university and general hospitals, differences in the scale of hospitals, or whether or not hospitals have received accreditation or ISO 15189. Regarding the IS, although the majority of facilities had sufficiently employed the access control to IS, there was some room for improvement in the management of special cases such as VIPs and patients with HIV infection. Furthermore, there were issues regarding the login method for computers shared by multiple staff, the showing of the names of personnel in charge of reports, and the risks associated with direct connections to systems and the Internet and the use of portable media such as USB memory sticks. These results indicated that further efforts are necessary for each facility to continue self-assessment and make improvements.

  14. Fluid dynamics structures in a fire environment observed in laboratory-scale experiments

    Treesearch

    J. Lozano; W. Tachajapong; D.R. Weise; S. Mahalingam; M. Princevac

    2010-01-01

    Particle Image Velocimetry (PIV) measurements were performed in laboratory-scale experimental fires spreading across horizontal fuel beds composed of aspen (Populus tremuloides Michx) excelsior. The continuous flame, intermittent flame, and thermal plume regions of a fire were investigated. Utilizing a PIV system, instantaneous velocity fields for...

  15. Regeneration of Exhausted Arsenic Adsorptive media of a Full Scale Treatment System

    EPA Science Inventory

    This presentation will describe the method and results of laboratory tests showing the feasibility of regenerating exhausted, iron-based, adsorptive media and the results of a follow up regeneration test at a full scale system in Twentynine Palms CA. The laboratory studies on se...

  16. Towards a better understanding of the cracking behavior in soils

    USDA-ARS?s Scientific Manuscript database

    Understanding and modeling shrinkage-induced cracks helps bridge the gap between flow problem in the laboratory and at the field. Modeling flow at the field scale with Darcian fluxes developed at the laboratory scales is challenged with preferential flows attributed to the cracking behavior of soils...

  17. Fate of estrone in laboratory-scale constructed wetlands

    USDA-ARS?s Scientific Manuscript database

    A horizontal, subsurface, laboratory-scale constructed wetland (CW) consisting of four cells in series was used to determine the attenuation of the steroid hormone estrone (E1) present in animal wastewater. Liquid swine manure diluted 1:80 with farm pond water and dosed with [14C]E1 flowed through ...

  18. Silica Exposures in Artisanal Small-Scale Gold Mining in Tanzania and Implications for Tuberculosis Prevention.

    PubMed

    Gottesfeld, Perry; Andrew, Damian; Dalhoff, Jeffrey

    2015-01-01

    Gold miners exposed to crystalline silica are at risk of silicosis, lung cancer, and experience higher incidence rates of pulmonary tuberculosis (TB). Although the hazards associated with mercury exposure in artisanal small-scale gold mining (ASGM) have been well documented, no published data was available on crystalline silica exposures in this population. Air sampling was conducted in the breathing zone of workers in five villages in Tanzania with battery-operated sampling pumps and bulk samples were collected to measure the type and concentration of crystalline silica in the ore. Samples were analyzed at an accredited laboratory with X-ray diffraction. Airborne crystalline silica exposures exceeded recommended limits for all tasks monitored with an average exposure of 16.85 mg/m(3) for underground drilling that was 337 fold greater than the recommended exposure limit (REL) published by the U.S. National Institute for Occupational Safety and Health (NIOSH) and 0.19 mg/m(3) for aboveground operations or 4-fold greater than the REL. The exposures measured raise concern for possible acute and chronic silicosis and are known to significantly contribute to TB incidence rates in mining communities. The use of wet methods could greatly reduce exposures and the risk of TB and silicosis in ASGM. Ongoing efforts to address mercury and other hazards in ASGM should incorporate crystalline silica dust controls.

  19. Serological diagnosis of Leptospirosis in bovine serum samples using a microsphere immunoassay.

    PubMed

    Wynwood, S J; Burns, M A; Graham, G C; Weier, S L; McKay, D B; Craig, S B

    2016-01-01

    Leptospirosis causes significant economic loss within the cattle industry worldwide. Current diagnostic methods are generally inadequate for dealing with large numbers of samples, are outdated, and provide little useful diagnostic and epidemiological information. This aim of this study was to apply a microsphere immunoassay (MIA), utilising Luminex xMap technology, to 200 bovine serum samples to determine this method's usefulness in leptospirosis diagnosis in comparison with the current gold standard, the microscopic agglutination test (MAT). Although MAT is the most widely used laboratory test for the diagnosis of leptospirosis, its reliance on live cultures, subjective interpretation of results and an inability to differentiate between antibody classes, suggest MAT is no longer the best method for the diagnosis of leptospirosis. The results presented in this paper show that MIA was able to determine reactive from non-reactive samples when compared with MAT, and was able to differentiate IgG and IgM classes of antibody. The results suggest increased sensitivity in MIA and the ability to multiplex up to 500 antigens at one time allows for significant improvements in cost-effectiveness as well as a reduced dependency on live cultures. The relatively low cost, high throughput platform and differentiation of antibody class, as shown in previous research, make this assay worthy of consideration for the diagnosis of leptospirosis in small-scale or large-scale bovine populations.

  20. Serological diagnosis of Leptospirosis in bovine serum samples using a microsphere immunoassay

    PubMed Central

    Wynwood, S. J.; Burns, M. A.; Graham, G. C.; Weier, S. L.; McKay, D. B.; Craig, S. B.

    2016-01-01

    Leptospirosis causes significant economic loss within the cattle industry worldwide. Current diagnostic methods are generally inadequate for dealing with large numbers of samples, are outdated, and provide little useful diagnostic and epidemiological information. This aim of this study was to apply a microsphere immunoassay (MIA), utilising Luminex xMap technology, to 200 bovine serum samples to determine this method's usefulness in leptospirosis diagnosis in comparison with the current gold standard, the microscopic agglutination test (MAT). Although MAT is the most widely used laboratory test for the diagnosis of leptospirosis, its reliance on live cultures, subjective interpretation of results and an inability to differentiate between antibody classes, suggest MAT is no longer the best method for the diagnosis of leptospirosis. The results presented in this paper show that MIA was able to determine reactive from non-reactive samples when compared with MAT, and was able to differentiate IgG and IgM classes of antibody. The results suggest increased sensitivity in MIA and the ability to multiplex up to 500 antigens at one time allows for significant improvements in cost-effectiveness as well as a reduced dependency on live cultures. The relatively low cost, high throughput platform and differentiation of antibody class, as shown in previous research, make this assay worthy of consideration for the diagnosis of leptospirosis in small-scale or large-scale bovine populations. PMID:26835139

  1. A longitudinal evaluation of performance of automated BCR-ABL1 quantitation using cartridge-based detection system.

    PubMed

    Enjeti, Anoop; Granter, Neil; Ashraf, Asma; Fletcher, Linda; Branford, Susan; Rowlings, Philip; Dooley, Susan

    2015-10-01

    An automated cartridge-based detection system (GeneXpert; Cepheid) is being widely adopted in low throughput laboratories for monitoring BCR-ABL1 transcript in chronic myelogenous leukaemia. This Australian study evaluated the longitudinal performance specific characteristics of the automated system.The automated cartridge-based system was compared prospectively with the manual qRT-PCR-based reference method at SA Pathology, Adelaide, over a period of 2.5 years. A conversion factor determination was followed by four re-validations. Peripheral blood samples (n = 129) with international scale (IS) values within detectable range were selected for assessment. The mean bias, proportion of results within specified fold difference (2-, 3- and 5-fold), the concordance rate of major molecular remission (MMR) and concordance across a range of IS values on paired samples were evaluated.The initial conversion factor for the automated system was determined as 0.43. Except for the second re-validation, where a negative bias of 1.9-fold was detected, all other biases fell within desirable limits. A cartridge-specific conversion factor and efficiency value was introduced and the conversion factor was confirmed to be stable in subsequent re-validation cycles. Concordance with the reference method/laboratory at >0.1-≤10 IS was 78.2% and at ≤0.001 was 80%, compared to 86.8% in the >0.01-≤0.1 IS range. The overall and MMR concordance were 85.7% and 94% respectively, for samples that fell within ± 5-fold of the reference laboratory value over the entire period of study.Conversion factor and performance specific characteristics for the automated system were longitudinally stable in the clinically relevant range, following introduction by the manufacturer of lot specific efficiency values.

  2. Fate of the antibiotic sulfadiazine in natural soils: Experimental and numerical investigations.

    PubMed

    Engelhardt, Irina; Sittig, Stephan; Šimůnek, Jirka; Groeneweg, Joost; Pütz, Thomas; Vereecken, Harry

    2015-01-01

    Based on small-scale laboratory and field-scale lysimeter experiments, the sorption and biodegradation of sulfonamide sulfadiazine (SDZ) were investigated in unsaturated sandy and silty-clay soils. Sorption and biodegradation were low in the laboratory, while the highest leaching rates were observed when SDZ was mixed with manure. The leaching rate decreased when SDZ was mixed with pure water, and was smallest with the highest SDZ concentrations. In the laboratory, three transformation products (TPs) developed after an initial lag phase. However, the amount of TPs was different for different mixing-scenarios. The TP 2-aminopyrimidine was not observed in the laboratory, but was the most prevalent TP at the field scale. Sorption was within the same range at the laboratory and field scales. However, distinctive differences occurred with respect to biodegradation, which was higher in the field lysimeters than at the laboratory scale. While the silty-clay soil favored sorption of SDZ, the sandy, and thus highly permeable, soil was characterized by short half-lives and thus a quick biodegradation of SDZ. For 2-aminopyrimidine, half-lives of only a few days were observed. Increased field-scale biodegradation in the sandy soil resulted from a higher water and air permeability that enhanced oxygen transport and limited oxygen depletion. Furthermore, low pH was more important than the organic matter and clay content for increasing the biodegradation of SDZ. A numerical analysis of breakthrough curves of bromide, SDZ, and its TPs showed that preferential flow pathways strongly affected the solute transport within shallow parts of the soil profile at the field scale. However, this effect was reduced in deeper parts of the soil profile. Due to high field-scale biodegradation in several layers of both soils, neither SDZ nor 2-aminopyrimidine was detected in the discharge of the lysimeter at a depth of 1m. Synthetic 50 year long simulations, which considered the application of manure with SDZ for general agricultural practices in Germany and humid climate conditions, showed that the concentration of SDZ decreased below 0.1 μg/L in both soils below the depth of 50 cm. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Fate of the antibiotic sulfadiazine in natural soils: Experimental and numerical investigations

    NASA Astrophysics Data System (ADS)

    Engelhardt, Irina; Sittig, Stephan; Šimůnek, Jirka; Groeneweg, Joost; Pütz, Thomas; Vereecken, Harry

    2015-06-01

    Based on small-scale laboratory and field-scale lysimeter experiments, the sorption and biodegradation of sulfonamide sulfadiazine (SDZ) were investigated in unsaturated sandy and silty-clay soils. Sorption and biodegradation were low in the laboratory, while the highest leaching rates were observed when SDZ was mixed with manure. The leaching rate decreased when SDZ was mixed with pure water, and was smallest with the highest SDZ concentrations. In the laboratory, three transformation products (TPs) developed after an initial lag phase. However, the amount of TPs was different for different mixing-scenarios. The TP 2-aminopyrimidine was not observed in the laboratory, but was the most prevalent TP at the field scale. Sorption was within the same range at the laboratory and field scales. However, distinctive differences occurred with respect to biodegradation, which was higher in the field lysimeters than at the laboratory scale. While the silty-clay soil favored sorption of SDZ, the sandy, and thus highly permeable, soil was characterized by short half-lives and thus a quick biodegradation of SDZ. For 2-aminopyrimidine, half-lives of only a few days were observed. Increased field-scale biodegradation in the sandy soil resulted from a higher water and air permeability that enhanced oxygen transport and limited oxygen depletion. Furthermore, low pH was more important than the organic matter and clay content for increasing the biodegradation of SDZ. A numerical analysis of breakthrough curves of bromide, SDZ, and its TPs showed that preferential flow pathways strongly affected the solute transport within shallow parts of the soil profile at the field scale. However, this effect was reduced in deeper parts of the soil profile. Due to high field-scale biodegradation in several layers of both soils, neither SDZ nor 2-aminopyrimidine was detected in the discharge of the lysimeter at a depth of 1 m. Synthetic 50 year long simulations, which considered the application of manure with SDZ for general agricultural practices in Germany and humid climate conditions, showed that the concentration of SDZ decreased below 0.1 μg/L in both soils below the depth of 50 cm.

  4. Use of Alum for Odor Reduction in Sludge and Biosolids from Different Wastewater Treatment Processes.

    PubMed

    Gruchlik, Yolanta; Fouché, Lise; Joll, Cynthia A; Heitz, Anna

    2017-12-01

      Applicability of alum addition to wastewater sludge and biosolids produced from different treatment processes was evaluated as a means of odor reduction. Four water resource recovery facilities (WRRFs) were chosen for this study: two used mesophilic anaerobic digestion and two used oxidation ditch processes. The experiments were conducted on a laboratory scale and in all cases the alum was added prior to dewatering. This is the first report of the application of alum for odor reduction in oxidation ditch processes. Alum addition was effective in reducing odors in anaerobically digested biosolids. Addition of 4% alum to anaerobically digested liquid biosolids prior to dewatering resulted in a 60% reduction in the peak odor concentration in the laboratory dewatered cake, relative to the control sample. Alum addition did not reduce odors in dewatered sludge from oxidation ditch processes.

  5. Injection-induced moment release can also be aseismic

    USGS Publications Warehouse

    McGarr, Arthur; Barbour, Andrew J.

    2018-01-01

    The cumulative seismic moment is a robust measure of the earthquake response to fluid injection for injection volumes ranging from 3100 to about 12 million m3. Over this range, the moment release is limited to twice the product of the shear modulus and the volume of injected fluid. This relation also applies at the much smaller injection volumes of the field experiment in France reported by Guglielmi, et al. (2015) and laboratory experiments to simulate hydraulic fracturing described by Goodfellow, et al. (2015). In both of these studies, the relevant moment release for comparison with the fluid injection was aseismic and consistent with the scaling that applies to the much larger volumes associated with injection-induced earthquakes with magnitudes extending up to 5.8. Neither the micro-earthquakes, at the site in France, nor the acoustic emission in the laboratory samples contributed significantly to the deformation due to fluid injection.

  6. Single shot near edge x-ray absorption fine structure spectroscopy in the laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mantouvalou, I., E-mail: ioanna.mantouvalou@tu-berlin.de; Witte, K.; Martyanov, W.

    With the help of adapted off-axis reflection zone plates, near edge X-ray absorption fine structure spectra at the C and N K-absorption edge have been recorded using a single 1.2 ns long soft X-ray pulse. The transmission experiments were performed with a laser-produced plasma source in the laboratory rendering time resolved measurements feasible independent on large scale facilities. A resolving power of E/ΔE ∼ 950 at the respective edges could be demonstrated. A comparison of single shot spectra with those collected with longer measuring time proves that all features of the used reference samples (silicon nitrate and polyimide) can be resolved in 1.2 ns.more » Hence, investigations of radiation sensitive biological specimen become possible due to the high efficiency of the optical elements enabling low dose experiments.« less

  7. Micropillar Compression Technique Applied to Micron-Scale Mudstone Elasto-Plastic Deformation

    NASA Astrophysics Data System (ADS)

    Dewers, T. A.; Boyce, B.; Buchheit, T.; Heath, J. E.; Chidsey, T.; Michael, J.

    2010-12-01

    Mudstone mechanical testing is often limited by poor core recovery and sample size, preservation and preparation issues, which can lead to sampling bias, damage, and time-dependent effects. A micropillar compression technique, originally developed by Uchic et al. 2004, here is applied to elasto-plastic deformation of small volumes of mudstone, in the range of cubic microns. This study examines behavior of the Gothic shale, the basal unit of the Ismay zone of the Pennsylvanian Paradox Formation and potential shale gas play in southeastern Utah, USA. Precision manufacture of micropillars 5 microns in diameter and 10 microns in length are prepared using an ion-milling method. Characterization of samples is carried out using: dual focused ion - scanning electron beam imaging of nano-scaled pores and distribution of matrix clay and quartz, as well as pore-filling organics; laser scanning confocal (LSCM) 3D imaging of natural fractures; and gas permeability, among other techniques. Compression testing of micropillars under load control is performed using two different nanoindenter techniques. Deformation of 0.5 cm in diameter by 1 cm in length cores is carried out and visualized by a microscope loading stage and laser scanning confocal microscopy. Axisymmetric multistage compression testing and multi-stress path testing is carried out using 2.54 cm plugs. Discussion of results addresses size of representative elementary volumes applicable to continuum-scale mudstone deformation, anisotropy, and size-scale plasticity effects. Other issues include fabrication-induced damage, alignment, and influence of substrate. This work is funded by the US Department of Energy, Office of Basic Energy Sciences. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy’s National Nuclear Security Administration under contract DE-AC04-94AL85000.

  8. Evaluation of laboratory powder X-ray micro-diffraction for applications in the fields of cultural heritage and forensic science.

    PubMed

    Svarcová, Silvie; Kocí, Eva; Bezdicka, Petr; Hradil, David; Hradilová, Janka

    2010-09-01

    The uniqueness and limited amounts of forensic samples and samples from objects of cultural heritage together with the complexity of their composition requires the application of a wide range of micro-analytical methods, which are non-destructive to the samples, because these must be preserved for potential late revision. Laboratory powder X-ray micro-diffraction (micro-XRD) is a very effective non-destructive technique for direct phase analysis of samples smaller than 1 mm containing crystal constituents. It compliments optical and electron microscopy with elemental micro-analysis, especially in cases of complicated mixtures containing phases with similar chemical composition. However, modification of X-ray diffraction to the micro-scale together with its application for very heterogeneous real samples leads to deviations from the standard procedure. Knowledge of both the limits and the phenomena which can arise during the analysis is crucial for the meaningful and proper application of the method. We evaluated basic limits of micro-XRD equipped with a mono-capillary with an exit diameter of 0.1 mm, for example the size of irradiated area, appropriate grain size, and detection limits allowing identification of given phases. We tested the reliability and accuracy of quantitative phase analysis based on micro-XRD data in comparison with conventional XRD (reflection and transmission), carrying out experiments with two-phase model mixtures simulating historic colour layers. Furthermore, we demonstrate the wide use of micro-XRD for investigation of various types of micro-samples (contact traces, powder traps, colour layers) and we show how to enhance data quality by proper choice of experiment geometry and conditions.

  9. Reproducibility of preclinical animal research improves with heterogeneity of study samples

    PubMed Central

    Vogt, Lucile; Sena, Emily S.; Würbel, Hanno

    2018-01-01

    Single-laboratory studies conducted under highly standardized conditions are the gold standard in preclinical animal research. Using simulations based on 440 preclinical studies across 13 different interventions in animal models of stroke, myocardial infarction, and breast cancer, we compared the accuracy of effect size estimates between single-laboratory and multi-laboratory study designs. Single-laboratory studies generally failed to predict effect size accurately, and larger sample sizes rendered effect size estimates even less accurate. By contrast, multi-laboratory designs including as few as 2 to 4 laboratories increased coverage probability by up to 42 percentage points without a need for larger sample sizes. These findings demonstrate that within-study standardization is a major cause of poor reproducibility. More representative study samples are required to improve the external validity and reproducibility of preclinical animal research and to prevent wasting animals and resources for inconclusive research. PMID:29470495

  10. Laboratory-based clinical audit as a tool for continual improvement: an example from CSF chemistry turnaround time audit in a South-African teaching hospital.

    PubMed

    Imoh, Lucius C; Mutale, Mubanga; Parker, Christopher T; Erasmus, Rajiv T; Zemlin, Annalise E

    2016-01-01

    Timeliness of laboratory results is crucial to patient care and outcome. Monitoring turnaround times (TAT), especially for emergency tests, is important to measure the effectiveness and efficiency of laboratory services. Laboratory-based clinical audits reveal opportunities for improving quality. Our aim was to identify the most critical steps causing a high TAT for cerebrospinal fluid (CSF) chemistry analysis in our laboratory. A 6-month retrospective audit was performed. The duration of each operational phase across the laboratory work flow was examined. A process-mapping audit trail of 60 randomly selected requests with a high TAT was conducted and reasons for high TAT were tested for significance. A total of 1505 CSF chemistry requests were analysed. Transport of samples to the laboratory was primarily responsible for the high average TAT (median TAT = 170 minutes). Labelling accounted for most delays within the laboratory (median TAT = 71 minutes) with most delays occurring after regular work hours (P < 0.05). CSF chemistry requests without the appropriate number of CSF sample tubes were significantly associated with delays in movement of samples from the labelling area to the technologist's work station (caused by a preference for microbiological testing prior to CSF chemistry). A laboratory-based clinical audit identified sample transportation, work shift periods and use of inappropriate CSF sample tubes as drivers of high TAT for CSF chemistry in our laboratory. The results of this audit will be used to change pre-analytical practices in our laboratory with the aim of improving TAT and customer satisfaction.

  11. Fast laboratory-based micro-computed tomography for pore-scale research: Illustrative experiments and perspectives on the future

    NASA Astrophysics Data System (ADS)

    Bultreys, Tom; Boone, Marijn A.; Boone, Matthieu N.; De Schryver, Thomas; Masschaele, Bert; Van Hoorebeke, Luc; Cnudde, Veerle

    2016-09-01

    Over the past decade, the wide-spread implementation of laboratory-based X-ray micro-computed tomography (micro-CT) scanners has revolutionized both the experimental and numerical research on pore-scale transport in geological materials. The availability of these scanners has opened up the possibility to image a rock's pore space in 3D almost routinely to many researchers. While challenges do persist in this field, we treat the next frontier in laboratory-based micro-CT scanning: in-situ, time-resolved imaging of dynamic processes. Extremely fast (even sub-second) micro-CT imaging has become possible at synchrotron facilities over the last few years, however, the restricted accessibility of synchrotrons limits the amount of experiments which can be performed. The much smaller X-ray flux in laboratory-based systems bounds the time resolution which can be attained at these facilities. Nevertheless, progress is being made to improve the quality of measurements performed on the sub-minute time scale. We illustrate this by presenting cutting-edge pore scale experiments visualizing two-phase flow and solute transport in real-time with a lab-based environmental micro-CT set-up. To outline the current state of this young field and its relevance to pore-scale transport research, we critically examine its current bottlenecks and their possible solutions, both on the hardware and the software level. Further developments in laboratory-based, time-resolved imaging could prove greatly beneficial to our understanding of transport behavior in geological materials and to the improvement of pore-scale modeling by providing valuable validation.

  12. FLARE: a New User Facility for Studies of Magnetic Reconnection Through Simultaneous, in-situ Measurements on MHD Scales, Ion Scales and Electron Scales

    NASA Astrophysics Data System (ADS)

    Ji, H.; Bhattacharjee, A.; Goodman, A.; Prager, S.; Daughton, W. S.; Cutler, R.; Fox, W.; Hoffmann, F.; Kalish, M.; Kozub, T.; Jara-Almonte, J.; Myers, C. E.; Ren, Y.; Sloboda, P.; Yamada, M.; Yoo, J.; Bale, S. D.; Carter, T.; Dorfman, S. E.; Drake, J. F.; Egedal, J.; Sarff, J.; Wallace, J.

    2017-12-01

    The FLARE device (Facility for Laboratory Reconnection Experiments; flare.pppl.gov) is a new laboratory experiment under construction at Princeton for the studies of magnetic reconnection in the multiple X-line regimes directly relevant to space, solar, astrophysical, and fusion plasmas, as guided by a reconnection phase diagram [Ji & Daughton, (2011)]. The whole device has been successfully assembled with rough leak check completed. The first plasmas are expected in the fall to winter. The main diagnostic is an extensive set of magnetic probe arrays to cover multiple scales from local electron scales ( ˜2 mm), to intermediate ion scales ( ˜10 cm), and global MHD scales ( ˜1 m), simultaneously providing in-situ measurements over all these relevant scales. By using these laboratory data, not only the detailed spatial profiles around each reconnecting X-line are available for direct comparisons with spacecraft data, but also the global conditions and consequences of magnetic reconnection, which are often difficult to quantify in space, can be controlled or studied systematically. The planned procedures and example topics as a user facility will be discussed in detail.

  13. Quality-assurance results for routine water analysis in US Geological Survey laboratories, water year 1991

    USGS Publications Warehouse

    Maloney, T.J.; Ludtke, A.S.; Krizman, T.L.

    1994-01-01

    The US. Geological Survey operates a quality- assurance program based on the analyses of reference samples for the National Water Quality Laboratory in Arvada, Colorado, and the Quality of Water Service Unit in Ocala, Florida. Reference samples containing selected inorganic, nutrient, and low ionic-strength constituents are prepared and disguised as routine samples. The program goal is to determine precision and bias for as many analytical methods offered by the participating laboratories as possible. The samples typically are submitted at a rate of approximately 5 percent of the annual environmental sample load for each constituent. The samples are distributed to the laboratories throughout the year. Analytical data for these reference samples reflect the quality of environmental sample data produced by the laboratories because the samples are processed in the same manner for all steps from sample login through data release. The results are stored permanently in the National Water Data Storage and Retrieval System. During water year 1991, 86 analytical procedures were evaluated at the National Water Quality Laboratory and 37 analytical procedures were evaluated at the Quality of Water Service Unit. An overall evaluation of the inorganic (major ion and trace metal) constituent data for water year 1991 indicated analytical imprecision in the National Water Quality Laboratory for 5 of 67 analytical procedures: aluminum (whole-water recoverable, atomic emission spectrometric, direct-current plasma); calcium (atomic emission spectrometric, direct); fluoride (ion-exchange chromatographic); iron (whole-water recoverable, atomic absorption spectrometric, direct); and sulfate (ion-exchange chromatographic). The results for 11 of 67 analytical procedures had positive or negative bias during water year 1991. Analytical imprecision was indicated in the determination of two of the five National Water Quality Laboratory nutrient constituents: orthophosphate as phosphorus and phosphorus. A negative or positive bias condition was indicated in three of five nutrient constituents. There was acceptable precision and no indication of bias for the 14 low ionic-strength analytical procedures tested in the National Water Quality Laboratory program and for the 32 inorganic and 5 nutrient analytical procedures tested in the Quality of Water Service Unit during water year 1991.

  14. Toward Active Control of Noise from Hot Supersonic Jets

    DTIC Science & Technology

    2013-11-15

    several laboratory - and full- scale data sets. Two different scaling scenarios are presented for the practising scientist to choose from. The first...As will be detailed below, this simple proof-of-concept experiment yielded good quality data that reveals details about the large-scale 3D structure...the light-field. Co-PI Thurow has recently designed and assembled a plenoptic camera in his laboratory with its key attributes being its compact

  15. Measurement of dissolved organic matter fluorescense in aquatic environments: An interlaboratory comparison

    USGS Publications Warehouse

    Murphy, Kathleen R.; Butler, Kenna D.; Spencer, Robert G. M.; Stedmon, Colin A.; Boehme, Jennifer R.; Aiken, George R.

    2010-01-01

    The fluorescent properties of dissolved organic matter (DOM) are often studied in order to infer DOM characteristics in aquatic environments, including source, quantity, composition, and behavior. While a potentially powerful technique, a single widely implemented standard method for correcting and presenting fluorescence measurements is lacking, leading to difficulties when comparing data collected by different research groups. This paper reports on a large-scale interlaboratory comparison in which natural samples and well-characterized fluorophores were analyzed in 20 laboratories in the U.S., Europe, and Australia. Shortcomings were evident in several areas, including data quality-assurance, the accuracy of spectral correction factors used to correct EEMs, and the treatment of optically dense samples. Data corrected by participants according to individual laboratory procedures were more variable than when corrected under a standard protocol. Wavelength dependency in measurement precision and accuracy were observed within and between instruments, even in corrected data. In an effort to reduce future occurrences of similar problems, algorithms for correcting and calibrating EEMs are described in detail, and MATLAB scripts for implementing the study's protocol are provided. Combined with the recent expansion of spectral fluorescence standards, this approach will serve to increase the intercomparability of DOM fluorescence studies.

  16. Twenty-eight Days to a Climax community: A Succession Laboratory Using Periphyton

    NASA Astrophysics Data System (ADS)

    Denicola, D. M.

    2005-05-01

    Succession in benthic algal communities (periphyton) occurs in a relatively short time scale because of the rapid reproductive rates of algae. To examine primary succession of periphyton in a lake and stream, unglazed tiles are placed in the respective habitats and sampled on days 4, 8, 16 and 28. Students count the preserved samples at 400X and identify taxa to genera based on customized picture keys (does not require a high degree of instructor expertise). Genera also are categorized according to algal growth forms, based on the size, shape, motility and attachment mechanism. After pooling the class data, students present the change in community structure, contrast succession between the lake and stream, and hypothesize which mechanisms may apply (facilitation, inhibition, tolerance). Successional sequences also are examined to see whether they agree with published growth form models for periphyton succession in lotic and lentic habitats. The laboratory uses the more intuitive method of repeated measures to study succession as an alternative to the often infeasible chronosequence method traditionally done for terrestrial communities. Additional outcomes include, reinforcement of the concept of species guilds (growth forms), an introduction into the use of empirical models, and an increased awareness of microorganism communities.

  17. Validation of a Cost-Efficient Multi-Purpose SNP Panel for Disease Based Research

    PubMed Central

    Hou, Liping; Phillips, Christopher; Azaro, Marco; Brzustowicz, Linda M.; Bartlett, Christopher W.

    2011-01-01

    Background Here we present convergent methodologies using theoretical calculations, empirical assessment on in-house and publicly available datasets as well as in silico simulations, that validate a panel of SNPs for a variety of necessary tasks in human genetics disease research before resources are committed to larger-scale genotyping studies on those samples. While large-scale well-funded human genetic studies routinely have up to a million SNP genotypes, samples in a human genetics laboratory that are not yet part of such studies may be productively utilized in pilot projects or as part of targeted follow-up work though such smaller scale applications require at least some genome-wide genotype data for quality control purposes such as DNA “barcoding” to detect swaps or contamination issues, determining familial relationships between samples and correcting biases due to population effects such as population stratification in pilot studies. Principal Findings Empirical performance in classification of relative types for any two given DNA samples (e.g., full siblings, parental, etc) indicated that for outbred populations the panel performs sufficiently to classify relationship in extended families and therefore also for smaller structures such as trios and for twin zygosity testing. Additionally, familial relationships do not significantly diminish the (mean match) probability of sharing SNP genotypes in pedigrees, further indicating the uniqueness of the “barcode.” Simulation using these SNPs for an African American case-control disease association study demonstrated that population stratification, even in complex admixed samples, can be adequately corrected under a range of disease models using the SNP panel. Conclusion The panel has been validated for use in a variety of human disease genetics research tasks including sample barcoding, relationship verification, population substructure detection and statistical correction. Given the ease of genotyping our specific assay contained herein, this panel represents a useful and economical panel for human geneticists. PMID:21611176

  18. Validation of a PCR-based method for the detection of various rendered materials in feedstuffs using a forensic DNA extraction kit.

    PubMed

    Myers, Michael J; Yancy, Haile F; Araneta, Michael; Armour, Jennifer; Derr, Janice; Hoostelaere, Lawrence A D; Farmer, Doris; Jackson, Falana; Kiessling, William M; Koch, Henry; Lin, Huahua; Liu, Yan; Mowlds, Gabrielle; Pinero, David; Riter, Ken L; Sedwick, John; Shen, Yuelian; Wetherington, June; Younkins, Ronsha

    2006-01-01

    A method trial was initiated to validate the use of a commercial DNA forensic kit to extract DNA from animal feed as part of a PCR-based method. Four different PCR primer pairs (one bovine pair, one porcine pair, one ovine primer pair, and one multispecies pair) were also evaluated. Each laboratory was required to analyze a total of 120 dairy feed samples either not fortified (control, true negative) or fortified with bovine meat and bone meal, porcine meat and bone meal (PMBM), or lamb meal. Feeds were fortified with the animal meals at a concentration of 0.1% (wt/wt). Ten laboratories participated in this trial, and each laboratory was required to evaluate two different primer pairs, i.e., each PCR primer pair was evaluated by five different laboratories. The method was considered to be validated for a given animal source when three or more laboratories achieved at least 97% accuracy (29 correct of 30 samples for 96.7% accuracy, rounded up to 97%) in detecting the fortified samples for that source. Using this criterion, the method was validated for the bovine primer because three laboratories met the criterion, with an average accuracy of 98.9%. The average false-positive rate was 3.0% in these laboratories. A fourth laboratory was 80% accurate in identifying the samples fortified with bovine meat and bone meal. A fifth laboratory was not able to consistently extract the DNA from the feed samples and did not achieve the criterion for accuracy for either the bovine or multispecies PCR primers. For the porcine primers, the method was validated, with four laboratories meeting the criterion for accuracy with an average accuracy of 99.2%. The fifth laboratory had a 93.3% accuracy outcome for the porcine primer. Collectively, these five laboratories had a 1.3% false-positive rate for the porcine primer. No laboratory was able to meet the criterion for accuracy with the ovine primers, most likely because of problems with the synthesis of the primer pair; none of the positive control DNA samples could be detected with the ovine primers. The multispecies primer pair was validated in three laboratories for use with bovine meat and bone meal and lamb meal but not with PMBM. The three laboratories had an average accuracy of 98.9% for bovine meat and bone meal, 97.8% for lamb meal, and 63.3% for PMBM. When examined on an individual laboratory basis, one of these four laboratories could not identify a single feed sample containing PMBM by using the multispecies primer, whereas the other laboratory identified only one PMBM-fortified sample, suggesting that the limit of detection for PMBM with this primer pair is around 0.1% (wt/wt). The results of this study demonstrated that the DNA forensic kit can be used to extract DNA from animal feed, which can then be used for PCR analysis to detect animal-derived protein present in the feed sample.

  19. Clinicians' interpretations of point of care urine culture versus laboratory culture results: analysis from the four-country POETIC trial of diagnosis of uncomplicated urinary tract infection in primary care.

    PubMed

    Hullegie, Saskia; Wootton, Mandy; Verheij, Theo J M; Thomas-Jones, Emma; Bates, Janine; Hood, Kerenza; Gal, Micaela; Francis, Nick A; Little, Paul; Moore, Michael; Llor, Carl; Pickles, Timothy; Gillespie, David; Kirby, Nigel; Brugman, Curt; Butler, Christopher C

    2017-08-01

    Urine culture at the point of care minimises delay between obtaining the sample and agar inoculation in a microbiology laboratory, and quantification and sensitivity results can be available more rapidly in primary care. To identify the degree to which clinicians' interpretations of a point-of-care-test (POCT) urine culture (Flexicult™ SSI-Urinary Kit) agrees with laboratory culture in women presenting to primary care with symptoms of uncomplicated urinary tract infections (UTI). Primary care clinicians used the Flexicult™-POCT, recorded their findings and took a photograph of the result, which was interpreted by microbiology laboratory technicians. Urine samples were additionally processed in routine care laboratories. Cross tabulations were used to identify important differences in organism identification, quantification and antibiotic susceptibility between these three sources of data. The influence of various laboratory definitions for UTI on culture were assessed. Primary care clinicians identified 202/289 urine samples (69.9%) as positive for UTI using the Flexicult™-POCT, whereas laboratory culture identified 94-190 (32.5-65.7%) as positive, depending on definition thresholds. 82.9% of samples identified positive for E. coli on laboratory culture were also considered positive for E. coli using the Flexicult™ -POCT, and susceptibilities were reasonably concordant. There were major discrepancies between laboratory staff interpretation of Flexicult™ photographs, clinicians' interpretation of the Flexicult™ test, and laboratory culture results. Flexicult™-POCT overestimated the positivity rate of urine samples for UTI when laboratory culture was used as the reference standard. However, it is unclear whether point-of-care or laboratory based urine culture provides the most valid diagnostic information. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  20. Experimental validation of microseismic emissions from a controlled hydraulic fracture in a synthetic layered medium

    NASA Astrophysics Data System (ADS)

    Roundtree, Russell

    A controlled hydraulic fracture experiment was performed on two medium sized (11" x 11" x 15") synthetic layered blocks of low permeability, low porosity Lyons sandstone sandwiched between cement. The purpose of the research was to better understand and characterize the fracture evolution as the fracture tip impinged upon the layer boundaries between the well bonded layers. It is also one of the first documented uses of passive microseismic used in a laboratory environment to characterize hydraulic fracturing. A relatively low viscosity fluid of 1000 centipoise, compared to properly scaled previous work (Casas 2005, and Athavale 2007), was pumped at a constant rate of 10 mL/minute through a steel cased hole landed and isolated in the sandstone layer. Efforts were made to contain the hydraulic fracture within the confines of the rock specimen to retain the created hydraulic fracture geometry. Two identical samples and treatment schedules were created and differed only in the monitoring system used to characterize the microseismic activity during the fracture treatment. The first block had eight embedded P-wave transducers placed in the sandstone layer to record the passive microseismic emissions and localize the location and time of the acoustic event. The second block had six compressional wave transducers and twelve shear wave transducers embedded in the sandstone layer of the block. The intention was to record and process the seismic data using conventional P-wave to S-wave difference timing techniques well known in industry. While this goal ultimately not possible due to the geometry of the receiver placements and the limitations of the Vallene acquisition processing software, the data received and the events localized from the 18 transducer test were of much higher numbers and quality than on the eight transducer test. This experiment proved conclusively that passive seismic emission recording can yield positive results in the laboratory. Just as in the field, this provides one of the best far field (away from the well bore) measurements to assess hydraulic fracture behavior. It also provides a calibration tool to extend laboratory results to field scale endeavors. The identification of strong microseismic activity at stress states far below fracture initiation confirms that rocks are critically stressed meta-stable materials and that microseismicity is caused by stress changes, not fractures directly. Advancements are necessary to fully exploit the potential of the microseismic method in laboratory sized samples. Both processing and visualization enhancements are necessary to realize the full benefits of this promising technology in the laboratory environment.

  1. A generic model for the shallow velocity structure of volcanoes

    NASA Astrophysics Data System (ADS)

    Lesage, Philippe; Heap, Michael J.; Kushnir, Alexandra

    2018-05-01

    The knowledge of the structure of volcanoes and of the physical properties of volcanic rocks is of paramount importance to the understanding of volcanic processes and the interpretation of monitoring observations. However, the determination of these structures by geophysical methods suffers limitations including a lack of resolution and poor precision. Laboratory experiments provide complementary information on the physical properties of volcanic materials and their behavior as a function of several parameters including pressure and temperature. Nevertheless combined studies and comparisons of field-based geophysical and laboratory-based physical approaches remain scant in the literature. Here, we present a meta-analysis which compares 44 seismic velocity models of the shallow structure of eleven volcanoes, laboratory velocity measurements on about one hundred rock samples from five volcanoes, and seismic well-logs from deep boreholes at two volcanoes. The comparison of these measurements confirms the strong variability of P- and S-wave velocities, which reflects the diversity of volcanic materials. The values obtained from laboratory experiments are systematically larger than those provided by seismic models. This discrepancy mainly results from scaling problems due to the difference between the sampled volumes. The averages of the seismic models are characterized by very low velocities at the surface and a strong velocity increase at shallow depth. By adjusting analytical functions to these averages, we define a generic model that can describe the variations in P- and S-wave velocities in the first 500 m of andesitic and basaltic volcanoes. This model can be used for volcanoes where no structural information is available. The model can also account for site time correction in hypocenter determination as well as for site and path effects that are commonly observed in volcanic structures.

  2. A Consistent System for Coding Laboratory Samples

    NASA Astrophysics Data System (ADS)

    Sih, John C.

    1996-07-01

    A formal laboratory coding system is presented to keep track of laboratory samples. Preliminary useful information regarding the sample (origin and history) is gained without consulting a research notebook. Since this system uses and retains the same research notebook page number for each new experiment (reaction), finding and distinguishing products (samples) of the same or different reactions becomes an easy task. Using this system multiple products generated from a single reaction can be identified and classified in a uniform fashion. Samples can be stored and filed according to stage and degree of purification, e.g. crude reaction mixtures, recrystallized samples, chromatographed or distilled products.

  3. Surface time-lapse electrical resistivity tomography (TLERT) monitoring of an SRS injection and associated biogeochemical processes, Oak Ridge National Laboratory, Tennessee USA

    NASA Astrophysics Data System (ADS)

    Baker, G. S.; Wu, Y.; Hubbard, S. S.; Wu, W.; Gaines, D. P.; Pratt, J. C.; Modi, A. L.; Watson, D.; Jardine, P.

    2009-05-01

    We present results from surface time-lapse electrical resistivity tomography (TLERT) data collected within a uranium-contaminated unconfined aquifer underlying the Oak Ridge Field Research Center (ORFRC) located at the Oak Ridge National Laboratory (ORNL) in Tennessee. As part of an Integrated Field Research Challenge (IFRC) project supported by the DOE Environmental Remediation Sciences Program (ERSP), bioreduction of U(VI) to U(IV) with ethanol as an electron donor has been tested during the last four years. Low U concentration (below US EPA MCL of 0.03 mg/L) can be achieved by frequent injection of electron donor. To reduce the costs and improve the sustainability for remediation and site maintenance, our IFRC team is exploring the effectiveness of a slowly degrading substrate such as commercial emulsified vegetable oil substrate (EVO) as alternative electron donor sources. Laboratory batch and flow-through column experiments were carried out to investigate the sensitivity of various physical properties (e.g., electrical conductivity) to EVO injection to test the applicability of geophysics as a monitoring tool at the field scale. Results revealed increased electrical conductivity during both EVO injection and subsequent degradation of surfactant with an overall increase in conductivity of ˜35%; thus, surface TLERT was selected as a monitoring tool to supplement well fluid samples. The field stimulation test began at Area 2 during early February 2009. Prior to the injection of the EVO, preliminary characterization completed, including a geochemical survey of the ground water from ˜50 wells, microbial samples of groundwater and sediment collected from selected wells, and site hydrology characterized by bromide tracer test and surface ERT methods. On February 9, 2009, diluted EVO solution (20% concentration, 900 gal vol) was injected into three injection wells within 1.5 hours. Distribution of the injected EVO and accompanying biogeochemical processes has been monitored since injection through analysis of numerous well fluid samples and TLERT data from 2 profiles. Initial TLERT data were collected at the 2 profiles over a two-week period at 12 different time steps. The surface profiles, situated parallel to and perpendicular to the major flow direction (as delineated by tracer tests), are each 40 m long and consist of 52 electrodes spaced at 0.75 m. Initial analysis indicate good correlation between well fluid samples and TLERT data and allow for improved extrapolation of well data to the field scale. Long-term monitoring is in place to track the continuing hydrologic dynamics and reduction duration in this test area throughout Spring 2009.

  4. Formaldehyde Exposures in a University Anatomy Laboratory

    NASA Astrophysics Data System (ADS)

    Winkler, Kyle William

    Air sampling studies were conducted within a university anatomical laboratory during the embalmment of a cadaver in order to determine if dangerous concentrations of formaldehyde existed. Three air sampling studies were conducted in the anatomical laboratory on three separate days that a cadaver was being embalmed. Samples were collected and analyzed using the Occupational Safety and Health Administration (OSHA) Sampling and Analytical Methods: Method 52. Each air sampling study sampled for short term exposure limit (STEL) and time weighted mean (TWA) breathing zone formaldehyde concentrations as well as area TWA formaldehyde concentrations. A personal aldehyde monitor was also used in each air sampling study to sample for breathing zone formaldehyde concentrations. Measured TWA mean exposures to formaldehyde ranged from 0.15--1.3 parts per million (ppm), STEL formaldehyde exposures ranged from 0.019--0.64 ppm, and eight-hour TWAs ranged from 0.03 to 3.6 ppm. All 8-hour TWA formaldehyde concentrations sampled in the anatomy laboratory during an embalmment were less than the permissible exposure limit (PEL) required by OSHA.

  5. Characterizing millisecond intermediates in hemoproteins using rapid-freeze-quench resonance Raman spectroscopy.

    PubMed

    Matsumura, Hirotoshi; Moënne-Loccoz, Pierre

    2014-01-01

    The combination of rapid freeze quenching (RFQ) with resonance Raman (RR) spectroscopy represents a unique tool with which to investigate the nature of short-lived intermediates formed during the enzymatic reactions of metalloproteins. Commercially available equipment allows trapping of intermediates within a millisecond to second time scale for low-temperature RR analysis resulting in the direct detection of metal-ligand vibrations and porphyrin skeletal vibrations in hemoproteins. This chapter briefly discusses RFQ-RR studies carried out previously in our laboratory and presents, as a practical example, protocols for the preparation of RFQ samples of the reaction of metmyoglobin with nitric oxide (NO) under anaerobic conditions. Also described are important controls and practical procedures for the analysis of these samples by low-temperature RR spectroscopy.

  6. Laboratory information management system: an example of international cooperation in Namibia.

    PubMed

    Colangeli, Patrizia; Ferrilli, Monica; Quaranta, Fabrizio; Malizia, Elio; Mbulu, Rosa-Stella; Mukete, Esther; Iipumbu, Lukas; Kamhulu, Anna; Tjipura-Zaire, Georgina; Di Francesco, Cesare; Lelli, Rossella; Scacchia, Massimo

    2012-01-01

    The authors describe the project undertaken by the Istituto G. Caporale to provide a laboratory information management system (LIMS) to the Central Veterinary Laboratory (CVL) in Windhoek, Namibia. This robust laboratory management tool satisfies Namibia's information obligations under international quality standard ISO 17025:2005. The Laboratory Information Management System (LIMS) for Africa was designed to collect and manage all necessary information on samples, tests and test results. The system involves the entry of sample data on arrival, as required by Namibian sampling plans, the tracking of samples through the various sections of the CVL, the collection of test results, generation of test reports and monitoring of outbreaks through data interrogation functions, eliminating multiple registrations of the same data on paper records. It is a fundamental component of the Namibian veterinary information system.

  7. Analysing attitude data through ridit schemes.

    PubMed

    El-rouby, M G

    1994-12-02

    The attitudes of individuals and populations on various issues are usually assessed through sample surveys. Responses to survey questions are then scaled and combined into a meaningful whole which defines the measured attitude. The applied scales may be of nominal, ordinal, interval, or ratio nature depending upon the degree of sophistication the researcher wants to introduce into the measurement. This paper discusses methods of analysis for categorical variables of the type used in attitude and human behavior research, and recommends adoption of ridit analysis, a technique which has been successfully applied to epidemiological, clinical investigation, laboratory, and microbiological data. The ridit methodology is described after reviewing some general attitude scaling methods and problems of analysis related to them. The ridit method is then applied to a recent study conducted to assess health care service quality in North Carolina. This technique is conceptually and computationally more simple than other conventional statistical methods, and is also distribution-free. Basic requirements and limitations on its use are indicated.

  8. Note: Measurement system for the radiative forcing of greenhouse gases in a laboratory scale.

    PubMed

    Kawamura, Yoshiyuki

    2016-01-01

    The radiative forcing of the greenhouse gases has been studied being based on computational simulations or the observation of the real atmosphere meteorologically. In order to know the greenhouse effect more deeply and to study it from various viewpoints, the study on it in a laboratory scale is important. We have developed a direct measurement system for the infrared back radiation from the carbon dioxide (CO2) gas. The system configuration is similar with that of the practical earth-atmosphere-space system. Using this system, the back radiation from the CO2 gas was directly measured in a laboratory scale, which roughly coincides with meteorologically predicted value.

  9. The New Big Science at the NSLS

    NASA Astrophysics Data System (ADS)

    Crease, Robert

    2016-03-01

    The term ``New Big Science'' refers to a phase shift in the kind of large-scale science that was carried out throughout the U.S. National Laboratory system, when large-scale materials science accelerators rather than high-energy physics accelerators became marquee projects at most major basic research laboratories in the post-Cold War era, accompanied by important changes in the character and culture of the research ecosystem at these laboratories. This talk explores some aspects of this phase shift at BNL's National Synchrotron Light Source.

  10. Spectral identification and quantification of salts in the Atacama Desert

    NASA Astrophysics Data System (ADS)

    Harris, J. K.; Cousins, C. R.; Claire, M. W.

    2016-10-01

    Salt minerals are an important natural resource. The ability to quickly and remotely identify and quantify salt deposits and salt contaminated soils and sands is therefore a priority goal for the various industries and agencies that utilise salts. The advent of global hyperspectral imagery from instruments such as Hyperion on NASA's Earth-Observing 1 satellite has opened up a new source of data that can potentially be used for just this task. This study aims to assess the ability of Visible and Near Infrared (VNIR) spectroscopy to identify and quantify salt minerals through the use of spectral mixture analysis. The surface and near-surface soils of the Atacama Desert in Chile contain a variety of well-studied salts, which together with low cloud coverage, and high aridity, makes this region an ideal testbed for this technique. Two forms of spectral data ranging 0.35 - 2.5 μm were collected: laboratory spectra acquired using an ASD FieldSpec Pro instrument on samples from four locations in the Atacama desert known to have surface concentrations of sulfates, nitrates, chlorides and perchlorates; and images from the EO-1 satellite's Hyperion instrument taken over the same four locations. Mineral identifications and abundances were confirmed using quantitative XRD of the physical samples. Spectral endmembers were extracted from within the laboratory and Hyperion spectral datasets and together with additional spectral library endmembers fed into a linear mixture model. The resulting identification and abundances from both dataset types were verified against the sample XRD values. Issues of spectral scale, SNR and how different mineral spectra interact are considered, and the utility of VNIR spectroscopy and Hyperion in particular for mapping specific salt concentrations in desert environments is established. Overall, SMA was successful at estimating abundances of sulfate minerals, particularly calcium sulfate, from both hyperspectral image and laboratory sample spectra, while abundance estimation of other salt phase spectral end-members was achieved with a higher degree of error.

  11. Changes in metal mobility associated with bark beetle-induced tree mortality.

    PubMed

    Mikkelson, Kristin M; Bearup, Lindsay A; Navarre-Sitchler, Alexis K; McCray, John E; Sharp, Jonathan O

    2014-05-01

    Recent large-scale beetle infestations have caused extensive mortality to conifer forests resulting in alterations to dissolved organic carbon (DOC) cycling, which in turn can impact metal mobility through complexation. This study analyzed soil-water samples beneath impacted trees in concert with laboratory flow-through soil column experiments to explore possible impacts of the bark beetle infestation on metal release and transport. The columns mimicked field conditions by introducing pine needle leachate and artificial rainwater through duplicate homogenized soil columns and measuring effluent metal (focusing on Al, Cu, and Zn) and DOC concentrations. All three metals were consistently found in higher concentrations in the effluent of columns receiving pine needle leachate. In both the field and laboratory, aluminum mobility was largely correlated with the hydrophobic fraction of the DOC, while copper had the largest correlation with total DOC concentrations. Geochemical speciation modeling supported the presence of DOC-metal complexes in column experiments. Copper soil water concentrations in field samples supported laboratory column results, as they were almost twice as high under grey phase trees than under red phase trees further signifying the importance of needle drop. Pine needle leachate contained high concentrations of Zn (0.1 mg l(-1)), which led to high effluent zinc concentrations and sorption of zinc to the soil matrix representing a future potential source for release. In support, field soil-water samples underneath beetle-impacted trees where the needles had recently fallen contained approximately 50% more zinc as samples from under beetle-impacted trees that still held their needles. The high concentrations of carbon in the pine needle leachate also led to increased sorption in the soil matrix creating the potential for subsequent carbon release. While unclear if manifested in adjacent surface waters, these results demonstrate an increased potential for Zn, Cu, and Al mobility, along with increased deposition of metals and carbon beneath beetle-impacted trees.

  12. The potamochemical symphony: new progress in the high-frequency acquisition of stream chemical data

    NASA Astrophysics Data System (ADS)

    Floury, Paul; Gaillardet, Jérôme; Gayer, Eric; Bouchez, Julien; Tallec, Gaëlle; Ansart, Patrick; Koch, Frédéric; Gorge, Caroline; Blanchouin, Arnaud; Roubaty, Jean-Louis

    2017-12-01

    Our understanding of hydrological and chemical processes at the catchment scale is limited by our capacity to record the full breadth of the information carried by river chemistry, both in terms of sampling frequency and precision. Here, we present a proof-of-concept study of a lab in the field called the River Lab (RL), based on the idea of permanently installing a suite of laboratory instruments in the field next to a river. Housed in a small shed, this set of instruments performs analyses at a frequency of one every 40 min for major dissolved species (Na+, K+, Mg2+, Ca2+, Cl-, SO42-, NO3-) through continuous sampling and filtration of the river water using automated ion chromatographs. The RL was deployed in the Orgeval Critical Zone Observatory, France for over a year of continuous analyses. Results show that the RL is able to capture long-term fine chemical variations with no drift and a precision significantly better than conventionally achieved in the laboratory (up to ±0.5 % for all major species for over a day and up to 1.7 % over 2 months). The RL is able to capture the abrupt changes in dissolved species concentrations during a typical 6-day rain event, as well as daily oscillations during a hydrological low-flow period of summer drought. Using the measured signals as a benchmark, we numerically assess the effects of a lower sampling frequency (typical of conventional field sampling campaigns) and of a lower precision (typically reached in the laboratory) on the hydrochemical signal. The high-resolution, high-precision measurements made possible by the RL open new perspectives for understanding critical zone hydro-bio-geochemical cycles. Finally, the RL also offers a solution for management agencies to monitor water quality in quasi-real time.

  13. Environmental research program for slagging fixed-bed coal gasification. Status report, November 1981

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilzbach, K. E.; Stetter, J. R.; Reilly, Jr., C. A.

    1982-02-01

    A collaborative environmental research program to provide information needed to assess the health and environmental effects associated with large-scale coal gasification technology is being conducted by Argonne National Laboratory (ANL) and the Grand Forks Energy Technology Center (GFETC). The objectives are to: investigate the toxicology and chemical composition of coal gasification by-products as a function of process variables and coal feed; compare the characteristics of isokinetic side-stream samples with those of process stream samples; identify the types of compounds responsible for toxicity; evaluate the chemical and toxicological effectiveness of various wastewater treatment operations; refine methodology for the collection and measurementmore » of organic vapors and particulates in workplace air; and obtain preliminary data on workplace air quality. So far the toxicities of a set of process stream samples (tar, oil, and gas liquor) and side-stream condensates from the GFETC gasifier have been measured in a battery of cellular screening tests for mutagenicity and cytotoxicity. Preliminary data on the effects of acute and chronic exposures of laboratory animals to process tar have been obtained. The process tar has been chemically fractionated and the distribution of mutagenicity and compound types among the fractions has been determined. Organic vapors and particulates collected at various times and locations in the gasifier building have been characterized.« less

  14. Experimental and Numerical Analysis of the Effects of Curing Time on Tensile Mechanical Properties of Thin Spray-on Liners

    NASA Astrophysics Data System (ADS)

    Guner, D.; Ozturk, H.

    2016-08-01

    The effects of curing time on tensile elastic material properties of thin spray-on liners (TSLs) were investigated in this study. Two different TSL products supplied by two manufacturers were tested comparatively. The "dogbone" tensile test samples that were prepared in laboratory conditions with different curing times (1, 7, 14, 21, and 28 days) were tested based on ASTM standards. It was concluded that longer curing times improves the tensile strength and the Young's Modulus of the TSLs but decreases their elongation at break. Moreover, as an additional conclusion of the testing procedure, it was observed that during the tensile tests, the common malpractice of measuring sample displacement from the grips of the loading machine with a linear variable displacement transducer versus the sample's gauge length had a major impact on modulus and deformation determination of TSLs. To our knowledge, true stress-strain curves were generated for the first time in TSL literature within this study. Numerical analyses of the laboratory tests were also conducted using Particle Flow Code in 2 Dimensions (PFC2D) in an attempt to guide TSL researchers throughout the rigorous PFC simulation process to model support behaviour of TSLs. A scaling coefficient between macro- and micro-properties of PFC was calculated which will help future TSL PFC modellers mimic their TSL behaviours for various tensile loading support scenarios.

  15. Defining distinct negative beliefs about uncertainty: validating the factor structure of the Intolerance of Uncertainty Scale.

    PubMed

    Sexton, Kathryn A; Dugas, Michel J

    2009-06-01

    This study examined the factor structure of the English version of the Intolerance of Uncertainty Scale (IUS; French version: M. H. Freeston, J. Rhéaume, H. Letarte, M. J. Dugas, & R. Ladouceur, 1994; English version: K. Buhr & M. J. Dugas, 2002) using a substantially larger sample than has been used in previous studies. Nonclinical undergraduate students and adults from the community (M age = 23.74 years, SD = 6.36; 73.0% female and 27.0% male) who participated in 16 studies in the Anxiety Disorders Laboratory at Concordia University in Montreal, Canada were randomly assigned to 2 datasets. Exploratory factor analysis with the 1st sample (n = 1,230) identified 2 factors: the beliefs that "uncertainty has negative behavioral and self-referent implications" and that "uncertainty is unfair and spoils everything." This 2-factor structure provided a good fit to the data (Bentler-Bonett normed fit index = .96, comparative fit index = .97, standardized root-mean residual = .05, root-mean-square error of approximation = .07) upon confirmatory factor analysis with the 2nd sample (n = 1,221). Both factors showed similarly high correlations with pathological worry, and Factor 1 showed stronger correlations with generalized anxiety disorder analogue status, trait anxiety, somatic anxiety, and depressive symptomatology. (PsycINFO Database Record (c) 2009 APA, all rights reserved).

  16. Maia Mapper: high definition XRF imaging in the lab

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ryan, Chris G.; Kirkham, R.; Moorhead, G. F.

    Here, Maia Mapper is a laboratory μXRF mapping system for efficient elemental imaging of drill core sections serving minerals research and industrial applications. It targets intermediate spatial scales, with imaging of up to ~80 M pixels over a 500×150 mm 2 sample area. It brings together (i) the Maia detector and imaging system, with its large solid-angle, event-mode operation, millisecond pixel transit times in fly-scan mode and real-time spectral deconvolution and imaging, (ii) the high brightness MetalJet D2 liquid metal micro-focus X-ray source from Excillum, and (iii) an efficient XOS polycapillary lens with a flux gain ~15,900 at 21 keVmore » into a ~32 μm focus, and (iv) a sample scanning stage engineered for standard drill-core sections. Count-rates up to ~3 M/s are observed on drill core samples with low dead-time up to ~1.5%. Automated scans are executed in sequence with display of deconvoluted element component images accumulated in real-time in the Maia detector. Application images on drill core and polished rock slabs illustrate Maia Mapper capabilities as part of the analytical workflow of the Advanced Resource Characterisation Facility, which spans spatial dimensions from ore deposit to atomic scales.« less

  17. Maia Mapper: high definition XRF imaging in the lab

    DOE PAGES

    Ryan, Chris G.; Kirkham, R.; Moorhead, G. F.; ...

    2018-03-13

    Here, Maia Mapper is a laboratory μXRF mapping system for efficient elemental imaging of drill core sections serving minerals research and industrial applications. It targets intermediate spatial scales, with imaging of up to ~80 M pixels over a 500×150 mm 2 sample area. It brings together (i) the Maia detector and imaging system, with its large solid-angle, event-mode operation, millisecond pixel transit times in fly-scan mode and real-time spectral deconvolution and imaging, (ii) the high brightness MetalJet D2 liquid metal micro-focus X-ray source from Excillum, and (iii) an efficient XOS polycapillary lens with a flux gain ~15,900 at 21 keVmore » into a ~32 μm focus, and (iv) a sample scanning stage engineered for standard drill-core sections. Count-rates up to ~3 M/s are observed on drill core samples with low dead-time up to ~1.5%. Automated scans are executed in sequence with display of deconvoluted element component images accumulated in real-time in the Maia detector. Application images on drill core and polished rock slabs illustrate Maia Mapper capabilities as part of the analytical workflow of the Advanced Resource Characterisation Facility, which spans spatial dimensions from ore deposit to atomic scales.« less

  18. Maia Mapper: high definition XRF imaging in the lab

    NASA Astrophysics Data System (ADS)

    Ryan, C. G.; Kirkham, R.; Moorhead, G. F.; Parry, D.; Jensen, M.; Faulks, A.; Hogan, S.; Dunn, P. A.; Dodanwela, R.; Fisher, L. A.; Pearce, M.; Siddons, D. P.; Kuczewski, A.; Lundström, U.; Trolliet, A.; Gao, N.

    2018-03-01

    Maia Mapper is a laboratory μXRF mapping system for efficient elemental imaging of drill core sections serving minerals research and industrial applications. It targets intermediate spatial scales, with imaging of up to ~80 M pixels over a 500×150 mm2 sample area. It brings together (i) the Maia detector and imaging system, with its large solid-angle, event-mode operation, millisecond pixel transit times in fly-scan mode and real-time spectral deconvolution and imaging, (ii) the high brightness MetalJet D2 liquid metal micro-focus X-ray source from Excillum, and (iii) an efficient XOS polycapillary lens with a flux gain ~15,900 at 21 keV into a ~32 μm focus, and (iv) a sample scanning stage engineered for standard drill-core sections. Count-rates up to ~3 M/s are observed on drill core samples with low dead-time up to ~1.5%. Automated scans are executed in sequence with display of deconvoluted element component images accumulated in real-time in the Maia detector. Application images on drill core and polished rock slabs illustrate Maia Mapper capabilities as part of the analytical workflow of the Advanced Resource Characterisation Facility, which spans spatial dimensions from ore deposit to atomic scales.

  19. Polyurethane foam (PUF) passive samplers for monitoring phenanthrene in stormwater.

    PubMed

    Dou, Yueqin; Zhang, Tian C; Zeng, Jing; Stansbury, John; Moussavi, Massoum; Richter-Egger, Dana L; Klein, Mitchell R

    2016-04-01

    Pollution from highway stormwater runoff has been an increasing area of concern. Many structural Best Management Practices (BMPs) have been implemented for stormwater treatment and management. One challenge for these BMPs is to sample stormwater and monitor BMP performance. The main objective of this study was to evaluate the feasibility of using polyurethane foam (PUF) passive samplers (PSs) for sampling phenanthrene (PHE) in highway stormwater runoff and BMPs. Tests were conducted using batch reactors, glass-tube columns, and laboratory-scale BMPs (bioretention cells). Results indicate that sorption for PHE by PUF is mainly linearly relative to time, and the high sorption capacity allows the PUF passive sampler to monitor stormwater events for months or years. The PUF passive samplers could be embedded in BMPs for monitoring influent and effluent PHE concentrations. Models developed to link the results of batch and column tests proved to be useful for determining removal or sorption parameters and performance of the PUF-PSs. The predicted removal efficiencies of BMPs were close to the real values obtained from the control columns with errors ranging between -8.46 and 1.52%. This research showed that it is possible to use PUF passive samplers for sampling stormwater and monitoring the performance of stormwater BMPs, which warrants the field-scale feasibility studies in the future.

  20. Uncertainty in predicting soil hydraulic properties at the hillslope scale with indirect methods

    NASA Astrophysics Data System (ADS)

    Chirico, G. B.; Medina, H.; Romano, N.

    2007-02-01

    SummarySeveral hydrological applications require the characterisation of the soil hydraulic properties at large spatial scales. Pedotransfer functions (PTFs) are being developed as simplified methods to estimate soil hydraulic properties as an alternative to direct measurements, which are unfeasible for most practical circumstances. The objective of this study is to quantify the uncertainty in PTFs spatial predictions at the hillslope scale as related to the sampling density, due to: (i) the error in estimated soil physico-chemical properties and (ii) PTF model error. The analysis is carried out on a 2-km-long experimental hillslope in South Italy. The method adopted is based on a stochastic generation of patterns of soil variables using sequential Gaussian simulation, conditioned to the observed sample data. The following PTFs are applied: Vereecken's PTF [Vereecken, H., Diels, J., van Orshoven, J., Feyen, J., Bouma, J., 1992. Functional evaluation of pedotransfer functions for the estimation of soil hydraulic properties. Soil Sci. Soc. Am. J. 56, 1371-1378] and HYPRES PTF [Wösten, J.H.M., Lilly, A., Nemes, A., Le Bas, C., 1999. Development and use of a database of hydraulic properties of European soils. Geoderma 90, 169-185]. The two PTFs estimate reliably the soil water retention characteristic even for a relatively coarse sampling resolution, with prediction uncertainties comparable to the uncertainties in direct laboratory or field measurements. The uncertainty of soil water retention prediction due to the model error is as much as or more significant than the uncertainty associated with the estimated input, even for a relatively coarse sampling resolution. Prediction uncertainties are much more important when PTF are applied to estimate the saturated hydraulic conductivity. In this case model error dominates the overall prediction uncertainties, making negligible the effect of the input error.

Top