Sample records for laboratory tests

  1. [Laboratory accreditation and proficiency testing].

    PubMed

    Kuwa, Katsuhiko

    2003-05-01

    ISO/TC 212 covering clinical laboratory testing and in vitro diagnostic test systems will issue the international standard for medical laboratory quality and competence requirements, ISO 15189. This standard is based on the ISO/IEC 17025, general requirements for competence of testing and calibration laboratories and ISO 9001, quality management systems-requirements. Clinical laboratory services are essential to patient care and therefore should be available to meet the needs of all patients and clinical personnel responsible for human health care. If a laboratory seeks accreditation, it should select an accreditation body that operates according to this international standard and in a manner which takes into account the particular requirements of clinical laboratories. Proficiency testing should be available to evaluate the calibration laboratories and reference measurement laboratories in clinical medicine. Reference measurement procedures should be of precise and the analytical principle of measurement applied should ensure reliability. We should be prepared to establish a quality management system and proficiency testing in clinical laboratories.

  2. Laboratory testing in hyperthyroidism.

    PubMed

    Grebe, Stefan K G; Kahaly, George J

    2012-09-01

    The clinical diagnosis of hypo- or hyperthyroidism is difficult (full text available online: http://education.amjmed.com/pp1/272). Clinical symptoms and signs are often non-specific, and there is incomplete correlation between structural and functional thyroid gland changes. Laboratory testing is therefore indispensible in establishing the diagnosis of thyrotoxicosis. Similar considerations apply to treatment monitoring. Laboratory testing also plays a crucial role in establishing the most likely cause for a patient's hyperthyroidism. Finally, during pregnancy, when isotopic scanning is relatively contraindicated and ultrasound is more difficult to interpret, laboratory testing becomes even more important. Copyright © 2012. Published by Elsevier Inc.

  3. 3. VIEW LOOKING NORTH, COMPONENTS TEST LABORATORY, DYNAMIC TEST FACILITY ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. VIEW LOOKING NORTH, COMPONENTS TEST LABORATORY, DYNAMIC TEST FACILITY (SATURN V IN BACKGROUND). - Marshall Space Flight Center, East Test Area, Components Test Laboratory, Huntsville, Madison County, AL

  4. Some new tests at the Gottingen laboratory

    NASA Technical Reports Server (NTRS)

    1921-01-01

    The tests at the Gottingen laboratory included: friction tests on a surface treated with omelette, verification tests on the M.V.A. 356 wing, and comparative tests of wing no. 36 at the Eiffel laboratory. The examination of all these experiments leads to the belief that, at large incidences, the speeds registered by the suction manometer of the testing chamber of the Eiffel laboratory wind tunnel are, owing to pressure drop, greater than the actual speeds. Therefore, the values of k(sub x) and k(sub y) measured at the Eiffel laboratory at large incidences are too low.

  5. Electromedical devices test laboratories accreditation

    NASA Astrophysics Data System (ADS)

    Murad, C.; Rubio, D.; Ponce, S.; Álvarez Abri, A.; Terrón, A.; Vicencio, D.; Fascioli, E.

    2007-11-01

    In the last years, the technology and equipment at hospitals have been increase in a great way as the risks of their implementation. Safety in medical equipment must be considered an important issue to protect patients and their users. For this reason, test and calibrations laboratories must verify the correct performance of this kind of devices under national and international standards. Is an essential mission for laboratories to develop their measurement activities taking into account a quality management system. In this article, we intend to transmit our experience working to achieve an accredited Test Laboratories for medical devices in National technological University.

  6. Misleading biochemical laboratory test results

    PubMed Central

    Nanji, Amin A.

    1984-01-01

    This article reviews the general and specific factors that interfere with the performance of common biochemical laboratory tests and the interpretation of their results. The clinical status of the patient, drug interactions, and in-vivo and in-vitro biochemical interactions and changes may alter the results obtained from biochemical analysis of blood constituents. Failure to recognize invalid laboratory test results may lead to injudicious and dangerous management of patients. PMID:6375845

  7. [How do hospital clinical laboratories and laboratory testing companies cooperate and build reciprocal relations?].

    PubMed

    Kawano, Seiji

    2014-12-01

    As the 2nd Joint Symposium of the Japanese Society of Laboratory Medicine and the Japanese Association of Laboratory Pathologists, the symposium on clinical test out-sourcing and branch laboratories was held at the 60th General Meeting of the Japanese Society of Laboratory Medicine on November 2nd, 2013 in Kobe. For the symposium, we conducted a questionnaire survey on the usage of clinical test out-sourcing and the introduction of branch laboratories to clinical laboratories of Japanese university hospitals, both private and public, between July 25th and August 20th, 2013. Seventy-two hospitals responded to the questionnaire survey, consisting of 41 public medical school hospitals and 31 private ones. According to the survey, the selection of each clinical test for out-sourcing was mainly determined by the capacities of hospital clinical laboratories and their equipment, as well as the profitability of each test. The main concerns of clinical laboratory members of university hospitals involved the continuity of measurement principles, traceability, and standardization of reference values for each test. They strongly requested the interchangeability and computerization of test data between laboratory testing companies. A branch laboratory was introduced to six hospitals, all of which were private medical college hospitals, out of 72 university hospitals, and eight of the other hospitals were open to its introduction. The merits and demerits of introducing a branch laboratory were also discussed. (Review).

  8. Structural Test Laboratory | Water Power | NREL

    Science.gov Websites

    Structural Test Laboratory Structural Test Laboratory NREL engineers design and configure structural components can validate models, demonstrate system reliability, inform design margins, and assess , including mass and center of gravity, to ensure compliance with design goals Dynamic Characterization Use

  9. 49 CFR 199.107 - Drug testing laboratory.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Drug testing laboratory. 199.107 Section 199.107... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.107 Drug testing laboratory. (a) Each operator shall use for the drug testing required by this...

  10. 49 CFR 199.107 - Drug testing laboratory.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Drug testing laboratory. 199.107 Section 199.107... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.107 Drug testing laboratory. (a) Each operator shall use for the drug testing required by this...

  11. 49 CFR 199.107 - Drug testing laboratory.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Drug testing laboratory. 199.107 Section 199.107... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.107 Drug testing laboratory. (a) Each operator shall use for the drug testing required by this...

  12. 49 CFR 199.107 - Drug testing laboratory.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Drug testing laboratory. 199.107 Section 199.107... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.107 Drug testing laboratory. (a) Each operator shall use for the drug testing required by this...

  13. 49 CFR 199.107 - Drug testing laboratory.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Drug testing laboratory. 199.107 Section 199.107... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.107 Drug testing laboratory. (a) Each operator shall use for the drug testing required by this...

  14. Fuel Cell Development and Test Laboratory | Energy Systems Integration

    Science.gov Websites

    Facility | NREL Fuel Cell Development and Test Laboratory Fuel Cell Development and Test Laboratory The Energy System Integration Facility's Fuel Cell Development and Test Laboratory supports fuel a fuel cell test in the Fuel Cell Development and Test Laboratory. Capability Hubs The Fuel Cell

  15. External quality assessment of medical laboratories in Croatia: preliminary evaluation of post-analytical laboratory testing.

    PubMed

    Krleza, Jasna Lenicek; Dorotic, Adrijana; Grzunov, Ana

    2017-02-15

    Proper standardization of laboratory testing requires assessment of performance after the tests are performed, known as the post-analytical phase. A nationwide external quality assessment (EQA) scheme implemented in Croatia in 2014 includes a questionnaire on post-analytical practices, and the present study examined laboratory responses in order to identify current post-analytical phase practices and identify areas for improvement. In four EQA exercises between September 2014 and December 2015, 145-174 medical laboratories across Croatia were surveyed using the Module 11 questionnaire on the post-analytical phase of testing. Based on their responses, the laboratories were evaluated on four quality indicators: turnaround time (TAT), critical values, interpretative comments and procedures in the event of abnormal results. Results were presented as absolute numbers and percentages. Just over half of laboratories (56.3%) monitored TAT. Laboratories varied substantially in how they dealt with critical values. Most laboratories (65-97%) issued interpretative comments with test results. One third of medical laboratories (30.6-33.3%) issued abnormal test results without confirming them in additional testing. Our results suggest that the nationwide post-analytical EQA scheme launched in 2014 in Croatia has yet to be implemented to the full. To close the gaps between existing recommendations and laboratory practice, laboratory professionals should focus on ensuring that TAT is monitored and lists of critical values are established within laboratories. Professional bodies/institutions should focus on clarify and harmonized rules to standardized practices and applied for adding interpretative comments to laboratory test results and for dealing with abnormal test results.

  16. [Quality use of commercial laboratory for clinical testing services - considering laboratory's role].

    PubMed

    Ogawa, Shinji

    2014-12-01

    The number of commercial laboratories for clinical testing in Japan run privately has decreased to about 30 companies, and their business is getting tougher. Branch Lab. and FMS businesses have not expanded recently due to the new reimbursement system which adds an additional sample management fee, becoming effective in 2010. This presentation gives an outline of each role for hospital and commercial laboratories, and their pros & cons considering the current medical situation. Commercial laboratories have investigated how to utilize ICT systems for sharing test information between hospitals and our facilities. It would be very helpful to clarify issues for each hospital. We will develop and create new values for clinical laboratory testing services and forge mutually beneficial relationships with medical institutions. (Review).

  17. 19 CFR 151.54 - Testing by Customs laboratory.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Testing by Customs laboratory. 151.54 Section 151... Other Metal-Bearing Materials § 151.54 Testing by Customs laboratory. Samples taken in accordance with § 151.52 shall be promptly forwarded to the appropriate Customs laboratory for testing in accordance...

  18. How Reliable Is Laboratory Testing?

    MedlinePlus

    ... laboratory testing. (See Who's Who in the Lab .) Post-Analytic Activities After the test is completed, the result must be delivered in ... View Sources NOTE: This article is based on research that ... of the Lab Tests Online Editorial Review Board . This article is periodically ...

  19. Mars Science Laboratory Spacecraft Assembled for Testing

    NASA Technical Reports Server (NTRS)

    2008-01-01

    The major components of NASA's Mars Science Laboratory spacecraft cruise stage atop the aeroshell, which has the descent stage and rover inside were connected together in October 2008 for several weeks of system testing, including simulation of launch vibrations and deep-space environmental conditions.

    These components will be taken apart again, for further work on each of them, after the environmental testing. The Mars Science Laboratory spacecraft is being assembled and tested for launch in 2011.

    This image was taken inside the Spacecraft Assembly Facility at NASA's Jet Propulsion Laboratory, Pasadena, Calif., which manages the Mars Science Laboratory Project for the NASA Science Mission Directorate, Washington. JPL is a division of the California Institute of Technology.

  20. Grid Modernization Laboratory Consortium - Testing and Verification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kroposki, Benjamin; Skare, Paul; Pratt, Rob

    This paper highlights some of the unique testing capabilities and projects being performed at several national laboratories as part of the U. S. Department of Energy Grid Modernization Laboratory Consortium. As part of this effort, the Grid Modernization Laboratory Consortium Testing Network isbeing developed to accelerate grid modernization by enablingaccess to a comprehensive testing infrastructure and creating a repository of validated models and simulation tools that will be publicly available. This work is key to accelerating thedevelopment, validation, standardization, adoption, and deployment of new grid technologies to help meet U. S. energy goals.

  1. [Economic impact of external laboratory test].

    PubMed

    Takura, Tomoyuki

    2006-11-01

    The realities of the spread and the aim of the introduction, and an economical influence of an external laboratory tests were researched. As a result, 90% or more the ratio to have consigned the external whole became clear. But it is preferable to correspond about inspection item of about 70% in own facilities because of the characteristic of the medical institution and the inspection item. Moreover, when correct the unbridgeable gulf of characteristic of the realities of spread of present external laboratory tests inspection and the ranging of ideal external laboratory tests inspection that specialist thinks about, the needed medical payment was thought that the investment of about 50 billion yen a year was necessary to expand the inspection in own facilities, by calculated based on the stochastic model.

  2. Battery testing at Argonne National Laboratory

    NASA Astrophysics Data System (ADS)

    Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.

    1993-03-01

    Argonne National Laboratory's Analysis & Diagnostic Laboratory (ADL) tests advanced batteries under simulated electric and hybrid vehicle operating conditions. The ADL facilities also include a post-test analysis laboratory to determine, in a protected atmosphere if needed, component compositional changes and failure mechanisms. The ADL provides a common basis for battery performance characterization and life evaluations with unbiased application of tests and analyses. The battery evaluations and post-test examinations help identify factors that limit system performance and life and the most-promising R&D approaches for overcoming these limitations. Since 1991, performance characterizations and/or life evaluations have been conducted on eight battery technologies: Na/S, Li/S, Zn/Br, Ni/MH, Ni/Zn, Ni/Cd, Ni/Fe, and lead-acid. These evaluations were performed for the Department of Energy's. Office of Transportation Technologies, Electric and Hybrid Propulsion Division (DOE/OTT/EHP), and Electric Power Research Institute (EPRI) Transportation Program. The results obtained are discussed.

  3. Evaluation of Mycology Laboratory Proficiency Testing

    PubMed Central

    Reilly, Andrew A.; Salkin, Ira F.; McGinnis, Michael R.; Gromadzki, Sally; Pasarell, Lester; Kemna, Maggi; Higgins, Nancy; Salfinger, Max

    1999-01-01

    Changes over the last decade in overt proficiency testing (OPT) regulations have been ostensibly directed at improving laboratory performance on patient samples. However, the overt (unblinded) format of the tests and regulatory penalties associated with incorrect values allow and encourage laboratorians to take extra precautions with OPT analytes. As a result OPT may measure optimal laboratory performance instead of the intended target of typical performance attained during routine patient testing. This study addresses this issue by evaluating medical mycology OPT and comparing its fungal specimen identification error rates to those obtained in a covert (blinded) proficiency testing (CPT) program. Identifications from 188 laboratories participating in the New York State mycology OPT from 1982 to 1994 were compared with the identifications of the same fungi recovered from patient specimens in 1989 and 1994 as part of the routine procedures of 88 of these laboratories. The consistency in the identification of OPT specimens was sufficient to make accurate predictions of OPT error rates. However, while the error rates in OPT and CPT were similar for Candida albicans, significantly higher error rates were found in CPT for Candida tropicalis, Candida glabrata, and other common pathogenic fungi. These differences may, in part, be due to OPT’s use of ideal organism representatives cultured under optimum growth conditions. This difference, as well as the organism-dependent error rate differences, reflects the limitations of OPT as a means of assessing the quality of routine laboratory performance in medical mycology. PMID:10364601

  4. 42 CFR 493.1441 - Condition: Laboratories performing high complexity testing; laboratory director.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Laboratories performing high complexity testing; laboratory director. 493.1441 Section 493.1441 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY...

  5. 42 CFR 493.1441 - Condition: Laboratories performing high complexity testing; laboratory director.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing high complexity testing; laboratory director. 493.1441 Section 493.1441 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY...

  6. Antimicrobial susceptibility testing by Australian veterinary diagnostic laboratories.

    PubMed

    Hardefeldt, L Y; Marenda, M; Crabb, H; Stevenson, M A; Gilkerson, J R; Billman-Jacobe, H; Browning, G F

    2018-04-01

    The national strategy for tackling antimicrobial resistance highlights the need for antimicrobial stewardship in veterinary practice and for surveillance of antimicrobial susceptibility in veterinary pathogens. Diagnostic laboratories have an important role in facilitating both of these processes, but it is unclear whether data from veterinary diagnostic laboratories are similar enough to allow for compilation and if there is consistent promotion of appropriate antimicrobial use embedded in the approaches of different laboratories to susceptibility testing. A cross-sectional study of antimicrobial susceptibility testing and reporting procedures by Australian veterinary diagnostic laboratories was conducted in 2017 using an online questionnaire. All 18 veterinary diagnostic laboratories in Australia completed the questionnaire. Kirby-Bauer disc diffusion was the method predominantly used for antimicrobial susceptibility testing and was used to evaluate 86% of all isolates, although two different protocols were used across the 18 laboratories (CLSI 15/18, CDS 3/18). Minimum inhibitory concentrations were never reported by 61% of laboratories. Common isolates were consistently reported on across all species, except for gram-negative isolates in pigs, for which there was some variation in the approach to reporting. There was considerable diversity in the panels of antimicrobials used for susceptibility testing on common isolates and no consistency was apparent between laboratories for any bacterial species. We recommend that nationally agreed and consistent antimicrobial panels for routine susceptibility testing should be developed and a uniform set of guidelines should be adopted by veterinary diagnostic laboratories in Australia. © 2018 Australian Veterinary Association.

  7. Energy Systems High-Pressure Test Laboratory | Energy Systems Integration

    Science.gov Websites

    Facility | NREL Energy Systems High-Pressure Test Laboratory Energy Systems High-Pressure Test Laboratory In the Energy Systems Integration Facility's High-Pressure Test Laboratory, researchers can safely test high-pressure hydrogen components. Photo of researchers running an experiment with a hydrogen fuel

  8. Testing activities at the National Battery Test Laboratory

    NASA Astrophysics Data System (ADS)

    Hornstra, F.; Deluca, W. H.; Mulcahey, T. P.

    The National Battery Test Laboratory (NBTL) is an Argonne National Laboratory facility for testing, evaluating, and studying advanced electric storage batteries. The facility tests batteries developed under Department of Energy programs and from private industry. These include batteries intended for future electric vehicle (EV) propulsion, electric utility load leveling (LL), and solar energy storage. Since becoming operational, the NBTL has evaluated well over 1400 cells (generally in the form of three- to six-cell modules, but up to 140-cell batteries) of various technologies. Performance characterization assessments are conducted under a series of charge/discharge cycles with constant current, constant power, peak power, and computer simulated dynamic load profile conditions. Flexible charging algorithms are provided to accommodate the specific needs of each battery under test. Special studies are conducted to explore and optimize charge procedures, to investigate the impact of unique load demands on battery performance, and to analyze the thermal management requirements of battery systems.

  9. 49 CFR 40.85 - What drugs do laboratories test for?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.85 What drugs do laboratories test for? As a laboratory, you must test for the following five drugs or classes of drugs in a DOT drug... 49 Transportation 1 2013-10-01 2013-10-01 false What drugs do laboratories test for? 40.85 Section...

  10. 49 CFR 40.85 - What drugs do laboratories test for?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.85 What drugs do laboratories test for? As a laboratory, you must test for the following five drugs or classes of drugs in a DOT drug... 49 Transportation 1 2014-10-01 2014-10-01 false What drugs do laboratories test for? 40.85 Section...

  11. 49 CFR 40.85 - What drugs do laboratories test for?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.85 What drugs do laboratories test for? As a laboratory, you must test for the following five drugs or classes of drugs in a DOT drug... 49 Transportation 1 2011-10-01 2011-10-01 false What drugs do laboratories test for? 40.85 Section...

  12. 49 CFR 40.85 - What drugs do laboratories test for?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.85 What drugs do laboratories test for? As a laboratory, you must test for the following five drugs or classes of drugs in a DOT drug... 49 Transportation 1 2012-10-01 2012-10-01 false What drugs do laboratories test for? 40.85 Section...

  13. 49 CFR 40.85 - What drugs do laboratories test for?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.85 What drugs do laboratories test for? As a laboratory, you must test for the following five drugs or classes of drugs in a DOT drug... 49 Transportation 1 2010-10-01 2010-10-01 false What drugs do laboratories test for? 40.85 Section...

  14. 10 CFR 431.18 - Testing laboratories.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... EQUIPMENT Electric Motors Test Procedures, Materials Incorporated and Methods of Determining Efficiency... Technology/National Voluntary Laboratory Accreditation Program (NIST/NVLAP); or (2) A laboratory... of the National Institute of Standards and Technology (NIST) which is part of the U.S. Department of...

  15. Laboratory testing under managed care dominance in the USA

    PubMed Central

    Takemura, Y; Beck, J

    2001-01-01

    The uncontrolled escalation of total health care expenditure despite the government's endeavours during the past decades in the USA had led to the rapid infiltration of managed care organisations (MCOs). Traditional hospital based laboratories have been placed in a crucial situation with the advent of the managed care era. A massive reduction of in house testing urged them to develop strategies against financial difficulty. Consolidation and networking, participation in the outreach testing market, and emphasis on point of care/satellite laboratory testing in non-traditional, ambulatory settings are major strategies for the survival of hospital laboratories. Several physicians' office laboratories (POLS) have closed their doors in response both to regulatory restrictions imposed by the Clinical Laboratory Improvement Amendments of 1988 and to managed care infiltration. It seems likely that POLs and hospital laboratories will continue to reduce test volumes, whereas commercial reference laboratories will thrive through contracting with MCOs. In the current climate of managed care dominance in the USA, clinical laboratories are changing their basic operation focus and mission in response to the aggressively changing landscape. Key Words: laboratory testing • managed care organisations • survival strategies PMID:11215291

  16. Lipid and lipoprotein testing in resource-limited laboratories.

    PubMed

    Myers, Gary L

    2003-01-01

    The role of total cholesterol (TC) and lipoproteins in the assessment of coronary heart disease (CHD) is firmly established from population and intervention studies. Total and low-density lipoprotein cholesterol (LDLC) levels are positively associated with CHD, and high-density lipoprotein cholesterol (HDLC) levels are negatively associated with CHD. Efforts to identify and treat people at increased risk based on cholesterol and lipoprotein levels have led to more lipid testing and the need for very reliable test results. Thus, quality laboratory services are an essential component of healthcare delivery and play a vital role in any strategy to reduce morbidity and mortality from CHD. In laboratories with limited resources, establishing laboratory capability to measure CHD risk markers may be a considerable challenge. Laboratories face problems in selecting proper techniques, difficulties in equipment availability and maintenance, and shortage of supplies, staffing, and supervision. The Centers for Disease Control and Prevention (CDC) has been providing technical assistance for more than 30 years to laboratories that measure lipids and lipoproteins and is willing to provide technical assistance as needed for other laboratories to develop this capability. CDC can provide technical assistance to establish lipid and lipoprotein testing capability to support a CHD public health program in areas with limited laboratory resources. This assistance includes: selecting a suitable testing instrument; providing training for laboratory technicians; establishing a simple quality control plan; and instructing staff on how to prepare frozen serum control materials suitable for assessing accuracy of lipid and lipoprotein testing.

  17. Managing demand for laboratory tests: a laboratory toolkit.

    PubMed

    Fryer, Anthony A; Smellie, W Stuart A

    2013-01-01

    Healthcare budgets worldwide are facing increasing pressure to reduce costs and improve efficiency, while maintaining quality. Laboratory testing has not escaped this pressure, particularly since pathology investigations cost the National Health Service £2.5 billion per year. Indeed, the Carter Review, a UK Department of Health-commissioned review of pathology services in England, estimated that 20% of this could be saved by improving pathology services, despite an average annual increase of 8%-10% in workload. One area of increasing importance is managing the demands for pathology tests and reducing inappropriate requesting. The Carter Review estimated that 25% of pathology tests were unnecessary, representing a huge potential waste. Certainly, the large variability in levels of requesting between general practitioners suggests that inappropriate requesting is widespread. Unlocking the key to this variation and implementing measures to reduce inappropriate requesting would have major implications for patients and healthcare resources alike. This article reviews the approaches to demand management. Specifically, it aims to (a) define demand management and inappropriate requesting, (b) assess the drivers for demand management, (c) examine the various approaches used, illustrating the potential of electronic requesting and (d) provide a wider context. It will cover issues, such as educational approaches, information technology opportunities and challenges, vetting, duplicate request identification and management, the role of key performance indicators, profile composition and assessment of downstream impact of inappropriate requesting. Currently, many laboratories are exploring demand management using a plethora of disparate approaches. Hence, this review seeks to provide a 'toolkit' with the view to allowing laboratories to develop a standardised demand management strategy.

  18. Laboratory Diagnostics Market in East Africa: A Survey of Test Types, Test Availability, and Test Prices in Kampala, Uganda.

    PubMed

    Schroeder, Lee F; Elbireer, Ali; Jackson, J Brooks; Amukele, Timothy K

    2015-01-01

    Diagnostic laboratory tests are routinely defined in terms of their sensitivity, specificity, and ease of use. But the actual clinical impact of a diagnostic test also depends on its availability and price. This is especially true in resource-limited settings such as sub-Saharan Africa. We present a first-of-its-kind report of diagnostic test types, availability, and prices in Kampala, Uganda. Test types (identity) and availability were based on menus and volumes obtained from clinical laboratories in late 2011 in Kampala using a standard questionnaire. As a measure of test availability, we used the Availability Index (AI). AI is the combined daily testing volumes of laboratories offering a given test, divided by the combined daily testing volumes of all laboratories in Kampala. Test prices were based on a sampling of prices collected in person and via telephone surveys in 2015. Test volumes and menus were obtained for 95% (907/954) of laboratories in Kampala city. These 907 laboratories offered 100 different test types. The ten most commonly offered tests in decreasing order were Malaria, HCG, HIV serology, Syphilis, Typhoid, Urinalysis, Brucellosis, Stool Analysis, Glucose, and ABO/Rh. In terms of AI, the 100 tests clustered into three groups: high (12 tests), moderate (33 tests), and minimal (55 tests) availability. 50% and 36% of overall availability was provided through private and public laboratories, respectively. Point-of-care laboratories contributed 35% to the AI of high availability tests, but only 6% to the AI of the other tests. The mean price of the most commonly offered test types was $2.62 (range $1.83-$3.46). One hundred different laboratory test types were in use in Kampala in late 2011. Both public and private laboratories were critical to test availability. The tests offered in point-of-care laboratories tended to be the most available tests. Prices of the most common tests ranged from $1.83-$3.46.

  19. 7 CFR 75.43 - Laboratory testing.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Laboratory testing. 75.43 Section 75.43 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... AND CERTIFICATION OF QUALITY OF AGRICULTURAL AND VEGETABLE SEEDS Fees and Charges § 75.43 Laboratory...

  20. 7 CFR 75.43 - Laboratory testing.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory testing. 75.43 Section 75.43 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... AND CERTIFICATION OF QUALITY OF AGRICULTURAL AND VEGETABLE SEEDS Fees and Charges § 75.43 Laboratory...

  1. Managing laboratory test ordering through test frequency filtering.

    PubMed

    Janssens, Pim M W; Wasser, Gerd

    2013-06-01

    Modern computer systems allow limits to be set on the periods allowed for repetitive testing. We investigated a computerised system for managing potentially overtly frequent laboratory testing, calculating the financial savings obtained. In consultation with hospital physicians, tests were selected for which 'spare periods' (periods during which tests are barred) might be set to control repetitive testing. The tests were selected and spare periods determined based on known analyte variations in health and disease, variety of tissues or cells giving rise to analytes, clinical conditions and rate of change determining analyte levels, frequency with which doctors need information about the analytes and the logistical needs of the clinic. The operation and acceptance of the system was explored with 23 analytes. Frequency filtering was subsequently introduced for 44 tests, each with their own spare periods. The proportion of tests barred was 0.56%, the most frequent of these being for total cholesterol, uric acid and HDL-cholesterol. The financial savings were 0.33% of the costs of all testing, with HbA1c, HDL-cholesterol and vitamin B12 yielding the largest savings. Following the introduction of the system the number of barred tests ultimately decreased, suggesting accommodation by the test requestors. Managing laboratory testing through computerised limits to prevent overtly frequent testing is feasible. The savings were relatively low, but sustaining the system takes little effort, giving little reason not to apply it. The findings will serve as a basis for improving the system and may guide others in introducing similar systems.

  2. Crime Laboratory Proficiency Testing Research Program.

    ERIC Educational Resources Information Center

    Peterson, Joseph L.; And Others

    A three-year research effort was conducted to design a crime laboratory proficiency testing program encompassing the United States. The objectives were to: (1) determine the feasibility of preparation and distribution of different classes of physical evidence; (2) assess the accuracy of criminalistics laboratories in the processing of selected…

  3. 42 CFR 493.1487 - Condition: Laboratories performing high complexity testing; testing personnel.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing high complexity testing; testing personnel. 493.1487 Section 493.1487 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY...

  4. 42 CFR 493.1487 - Condition: Laboratories performing high complexity testing; testing personnel.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Laboratories performing high complexity testing; testing personnel. 493.1487 Section 493.1487 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY...

  5. Battery testing at Argonne National Laboratory

    NASA Astrophysics Data System (ADS)

    Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.

    Advanced battery technology evaluations are performed under simulated electric-vehicle operating conditions at the Analysis & Diagnostic Laboratory (ADL) of Argonne National Laboratory. The ADL results provide insight into those factors that limit battery performance and life. The ADL facilities include a test laboratory to conduct battery experimental evaluations under simulated application conditions and a post-test analysis laboratory to determine, in a protected atmosphere if needed, component compositional changes and failure mechanisms. This paper summarizes the performance characterizations and life evaluations conducted during FY-92 on both single cells and multi-cell modules that encompass six battery technologies (Na/S, Li/FeS, Ni/Metal-Hydride, Ni/Zn, Ni/Cd, Ni/Fe). These evaluations were performed for the Department of Energy, Office of Transportation Technologies, Electric and Hybrid Propulsion Division, and the Electric Power Research Institute. The ADL provides a common basis for battery performance characterization and life evaluations with unbiased application of tests and analyses. The results help identify the most promising R&D approaches for overcoming battery limitations, and provide battery users, developers, and program managers with a measure of the progress being made in battery R&D programs, a comparison of battery technologies, and basic data for modeling.

  6. Total laboratory automation: Do stat tests still matter?

    PubMed

    Dolci, Alberto; Giavarina, Davide; Pasqualetti, Sara; Szőke, Dominika; Panteghini, Mauro

    2017-07-01

    During the past decades the healthcare systems have rapidly changed and today hospital care is primarily advocated for critical patients and acute treatments, for which laboratory test results are crucial and need to be always reported in predictably short turnaround time (TAT). Laboratories in the hospital setting can face this challenge by changing their organization from a compartmentalized laboratory department toward a decision making-based laboratory department. This requires the implementation of a core laboratory, that exploits total laboratory automation (TLA) using technological innovation in analytical platforms, track systems and information technology, including middleware, and a number of satellite specialized laboratory sections cooperating with care teams for specific medical conditions. In this laboratory department model, the short TAT for all first-line tests performed by TLA in the core laboratory represents the key paradigm, where no more stat testing is required because all samples are handled in real-time and (auto)validated results dispatched in a time that fulfills clinical needs. To optimally reach this goal, laboratories should be actively involved in managing all the steps covering the total examination process, speeding up also extra-laboratory phases, such sample delivery. Furthermore, to warrant effectiveness and not only efficiency, all the processes, e.g. specimen integrity check, should be managed by middleware through a predefined set of rules defined in light of the clinical governance. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  7. 21 CFR 640.67 - Laboratory tests.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.67 Laboratory tests. Each unit of Source Plasma shall be tested for evidence of infection due to communicable disease agents as required...

  8. 21 CFR 640.67 - Laboratory tests.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.67 Laboratory tests. Each unit of Source Plasma shall be tested for evidence of infection due to communicable disease agents as required...

  9. 21 CFR 640.67 - Laboratory tests.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.67 Laboratory tests. Each unit of Source Plasma shall be tested for evidence of infection due to communicable disease agents as required...

  10. 21 CFR 640.67 - Laboratory tests.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.67 Laboratory tests. Each unit of Source Plasma shall be tested for evidence of infection due to communicable disease agents as required...

  11. 21 CFR 640.67 - Laboratory tests.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.67 Laboratory tests. Each unit of Source Plasma shall be tested for evidence of infection due to communicable disease agents as required...

  12. Laboratory testing of two prototype in-vehicle breath test devices

    DOT National Transportation Integrated Search

    1985-08-01

    This report presents the results of laboratory testing of two recently developed prototype in-vehicle breath test devices. These devices are designed to prevent persons with alcohol on their breath from driving a car. The devices tested were the SOBE...

  13. Impact of Laboratory Test Use Strategies in a Turkish Hospital

    PubMed Central

    Yılmaz, Fatma Meriç; Kahveci, Rabia; Aksoy, Altan; Özer Kucuk, Emine; Akın, Tezcan; Mathew, Joseph Lazar; Meads, Catherine; Zengin, Nurullah

    2016-01-01

    Objectives Eliminating unnecessary laboratory tests is a good way to reduce costs while maintain patient safety. The aim of this study was to define and process strategies to rationalize laboratory use in Ankara Numune Training and Research Hospital (ANH) and calculate potential savings in costs. Methods A collaborative plan was defined by hospital managers; joint meetings with ANHTA and laboratory professors were set; the joint committee invited relevant staff for input, and a laboratory efficiency committee was created. Literature was reviewed systematically to identify strategies used to improve laboratory efficiency. Strategies that would be applicable in local settings were identified for implementation, processed, and the impact on clinical use and costs assessed for 12 months. Results Laboratory use in ANH differed enormously among clinics. Major use was identified in internal medicine. The mean number of tests per patient was 15.8. Unnecessary testing for chloride, folic acid, free prostate specific antigen, hepatitis and HIV testing were observed. Test panel use was pinpointed as the main cause of overuse of the laboratory and the Hospital Information System test ordering page was reorganized. A significant decrease (between 12.6–85.0%) was observed for the tests that were taken to an alternative page on the computer screen. The one year study saving was equivalent to 371,183 US dollars. Conclusion Hospital-based committees including laboratory professionals and clinicians can define hospital based problems and led to a standardized approach to test use that can help clinicians reduce laboratory costs through appropriate use of laboratory tests. PMID:27077653

  14. 42 CFR 493.1403 - Condition: Laboratories performing moderate complexity testing; laboratory director.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing moderate complexity testing; laboratory director. 493.1403 Section 493.1403 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION...

  15. 42 CFR 493.1403 - Condition: Laboratories performing moderate complexity testing; laboratory director.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Laboratories performing moderate complexity testing; laboratory director. 493.1403 Section 493.1403 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION...

  16. Point-of-Care Test Equipment for Flexible Laboratory Automation.

    PubMed

    You, Won Suk; Park, Jae Jun; Jin, Sung Moon; Ryew, Sung Moo; Choi, Hyouk Ryeol

    2014-08-01

    Blood tests are some of the core clinical laboratory tests for diagnosing patients. In hospitals, an automated process called total laboratory automation, which relies on a set of sophisticated equipment, is normally adopted for blood tests. Noting that the total laboratory automation system typically requires a large footprint and significant amount of power, slim and easy-to-move blood test equipment is necessary for specific demands such as emergency departments or small-size local clinics. In this article, we present a point-of-care test system that can provide flexibility and portability with low cost. First, the system components, including a reagent tray, dispensing module, microfluidic disk rotor, and photometry scanner, and their functions are explained. Then, a scheduler algorithm to provide a point-of-care test platform with an efficient test schedule to reduce test time is introduced. Finally, the results of diagnostic tests are presented to evaluate the system. © 2014 Society for Laboratory Automation and Screening.

  17. Laboratory development and testing of spacecraft diagnostics

    NASA Astrophysics Data System (ADS)

    Amatucci, William; Tejero, Erik; Blackwell, Dave; Walker, Dave; Gatling, George; Enloe, Lon; Gillman, Eric

    2017-10-01

    The Naval Research Laboratory's Space Chamber experiment is a large-scale laboratory device dedicated to the creation of large-volume plasmas with parameters scaled to realistic space plasmas. Such devices make valuable contributions to the investigation of space plasma phenomena under controlled, reproducible conditions, allowing for the validation of theoretical models being applied to space data. However, in addition to investigations such as plasma wave and instability studies, such devices can also make valuable contributions to the development and testing of space plasma diagnostics. One example is the plasma impedance probe developed at NRL. Originally developed as a laboratory diagnostic, the sensor has now been flown on a sounding rocket, is included on a CubeSat experiment, and will be included on the DoD Space Test Program's STP-H6 experiment on the International Space Station. In this talk, we will describe how the laboratory simulation of space plasmas made this development path possible. Work sponsored by the US Naval Research Laboratory Base Program.

  18. Routine admission laboratory testing for general medical patients.

    PubMed

    Hubbell, F A; Frye, E B; Akin, B V; Rucker, L

    1988-06-01

    We evaluated the usefulness of commonly ordered routine admission laboratory tests in 301 patients admitted consecutively to the internal medicine wards of a university teaching hospital. Using a consensus analysis approach, three Department of Medicine faculty members reviewed the charts of admitted patients to determine the impact of the test results on patient care. The evaluated tests were the urinalysis, hematocrit, white blood cell count, platelet count, six-factor automated multiple analysis (serum sodium, potassium, chloride, bicarbonate, glucose, and blood urea nitrogen), prothrombin time, partial thromboplastin time, chest x-ray, and electrocardiogram. Forty-five percent of the 3,684 tests were ordered for patients without recognizable medical indications. Twelve percent of these routine tests were abnormal, 5% led to additional laboratory testing, but only 0.5% led to change in the treatment of patients. We conclude that the impact of routine admission laboratory testing on patient care is very small and that there is little justification for ordering tests solely because of hospital admission.

  19. 1. VIEW EAST, COMPONENTS TEST LABORATORY SHOWING CATCH BASINS, TURBINE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. VIEW EAST, COMPONENTS TEST LABORATORY SHOWING CATCH BASINS, TURBINE TESTING AREA, AND PUMP TESTING TOWER. - Marshall Space Flight Center, East Test Area, Components Test Laboratory, Huntsville, Madison County, AL

  20. Laboratory testing of Alcoscan saliva-alcohol test strips

    DOT National Transportation Integrated Search

    1986-10-01

    This report describes a laboratory evaluation of Alcoscan saliva-alcohol test strips. The objectives of this work were: (1) to determine the precision and accuracy of the Alcoscan strips; and (2) to determine what effect extreme ambient temperatures ...

  1. Laboratory and clinical evaluation of on-site urine drug testing.

    PubMed

    Beck, Olof; Carlsson, Sten; Tusic, Marinela; Olsson, Robert; Franzen, Lisa; Hulten, Peter

    2014-11-01

    Products for on-site urine drug testing offer the possibility to perform screening for drugs of abuse directly at the point-of-care. This is a well-established routine in emergency and dependency clinics but further evaluation of performance is needed due to inherent limitations with the available products. Urine drug testing by an on-site product was compared with routine laboratory methods. First, on-site testing was performed at the laboratory in addition to the routine method. Second, the on-site testing was performed at a dependency clinic and urine samples were subsequently sent to the laboratory for additional analytical investigation. The on-site testing products did not perform with assigned cut-off levels. The subjective reading between the presence of a spot (i.e. negative test result) being present or no spot (positive result) was difficult in 3.2% of the cases, and occurred for all parameters. The tests performed more accurately in drug negative samples (specificity 96%) but less accurately for detecting positives (sensitivity 79%). Of all incorrect results by the on-site test the proportion of false negatives was 42%. The overall agreement between on-site and laboratory testing was 95% in the laboratory study and 98% in the clinical study. Although a high degree of agreement was observed between on-site and routine laboratory urine drug testing, the performance of on-site testing was not acceptable due to significant number of false negative results. The limited sensitivity of on-site testing compared to laboratory testing reduces the applicability of these tests.

  2. A system dynamics approach to analyze laboratory test errors.

    PubMed

    Guo, Shijing; Roudsari, Abdul; Garcez, Artur d'Avila

    2015-01-01

    Although many researches have been carried out to analyze laboratory test errors during the last decade, it still lacks a systemic view of study, especially to trace errors during test process and evaluate potential interventions. This study implements system dynamics modeling into laboratory errors to trace the laboratory error flows and to simulate the system behaviors while changing internal variable values. The change of the variables may reflect a change in demand or a proposed intervention. A review of literature on laboratory test errors was given and provided as the main data source for the system dynamics model. Three "what if" scenarios were selected for testing the model. System behaviors were observed and compared under different scenarios over a period of time. The results suggest system dynamics modeling has potential effectiveness of helping to understand laboratory errors, observe model behaviours, and provide a risk-free simulation experiments for possible strategies.

  3. Iowa Central Quality Fuel Testing Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heach, Don; Bidieman, Julaine

    2013-09-30

    The objective of this project is to finalize the creation of an independent quality fuel testing laboratory on the campus of Iowa Central Community College in Fort Dodge, Iowa that shall provide the exploding biofuels industry a timely and cost-effective centrally located laboratory to complete all state and federal fuel and related tests that are required. The recipient shall work with various state regulatory agencies, biofuel companies and state and national industry associations to ensure that training and testing needs of their members and American consumers are met. The recipient shall work with the Iowa Department of Ag and Landmore » Stewardship on the development of an Iowa Biofuel Quality Standard along with the Development of a standard that can be used throughout industry.« less

  4. Developing a cardiopulmonary exercise testing laboratory.

    PubMed

    Diamond, Edward

    2007-12-01

    Cardiopulmonary exercise testing is a noninvasive and cost-effective technique that adds significant value to the assessment and management of a variety of symptoms and diseases. The penetration of this testing in medical practice may be limited by perceived operational and financial barriers. This article reviews coding and supervision requirements related to both simple and complex pulmonary stress testing. A program evaluation and review technique diagram is used to describe the work flow process. Data from our laboratory are used to generate an income statement that separates fixed and variable costs and calculates the contribution margin. A cost-volume-profit (break-even) analysis is then performed. Using data from our laboratory including fixed and variable costs, payer mix, reimbursements by payer, and the assumption that the studies are divided evenly between simple and complex pulmonary stress tests, the break-even number is calculated to be 300 tests per year. A calculator with embedded formulas has been designed by the author and is available on request. Developing a cardiopulmonary exercise laboratory is challenging but achievable and potentially profitable. It should be considered by a practice that seeks to distinguish itself as a quality leader. Providing this clinically valuable service may yield indirect benefits such as increased patient volume and increased utilization of other services provided by the practice. The decision for a medical practice to commit resources to managerial accounting support requires a cost-benefit analysis, but may be a worthwhile investment in our challenging economic environment.

  5. CTBTO Contractor Laboratory Test Sample Production Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bob Hague; Tracy Houghton; Nick Mann

    2013-08-01

    In October 2012 scientists from both Idaho National Laboratory (INL) and the CTBTO contact laboratory at Seibersdorf, Austria designed a system and capability test to determine if the INL could produce and deliver a short lived radio xenon standard in time for the standard to be measured at the CTBTO contact laboratory at Seibersdorf, Austria. The test included sample standard transportation duration and potential country entrance delays at customs. On October 23, 2012 scientists at the Idaho National Laboratory (INL) prepared and shipped a Seibersdorf contract laboratory supplied cylinder. The canister contained 1.0 scc of gas that consisted of 70%more » xenon and 30% nitrogen by volume. The t0 was October 24, 2012, 1200 ZULU. The xenon content was 0.70 +/ 0.01 scc at 0 degrees C. The 133mXe content was 4200 +/ 155 dpm per scc of stable xenon on t0 (1 sigma uncertainty). The 133Xe content was 19000 +/ 800 dpm per scc of stable xenon on t0 (1 sigma uncertainty).« less

  6. Parachute Testing for Mars Science Laboratory

    NASA Technical Reports Server (NTRS)

    2007-01-01

    The team developing the landing system for NASA's Mars Science Laboratory tested the deployment of an early parachute design in mid-October 2007 inside the world's largest wind tunnel, at NASA Ames Research Center, Moffett Field, California.

    In this image, an engineer is dwarfed by the parachute, which holds more air than a 280-square-meter (3,000-square-foot) house and is designed to survive loads in excess of 36,000 kilograms (80,000 pounds).

    The parachute, built by Pioneer Aerospace, South Windsor, Connecticut, has 80 suspension lines, measures more than 50 meters (165 feet) in length, and opens to a diameter of nearly 17 meters (55 feet). It is the largest disk-gap-band parachute ever built and is shown here inflated in the test section with only about 3.8 meters (12.5 feet) of clearance to both the floor and ceiling.

    The wind tunnel, which is 24 meters (80 feet) tall and 37 meters (120 feet) wide and big enough to house a Boeing 737, is part of the National Full-Scale Aerodynamics Complex, operated by the U.S. Air Force, Arnold Engineering Development Center.

    NASA's Jet Propulsion Laboratory, Pasadena, California, is building and testing the Mars Science Laboratory spacecraft for launch in 2009. The mission will land a roving analytical laboratory on the surface of Mars in 2010. JPL is a division of the California Institute of Technology.

  7. Inter-laboratory Comparison of Three Earplug Fit-test Systems

    PubMed Central

    Byrne, David C.; Murphy, William J.; Krieg, Edward F.; Ghent, Robert M.; Michael, Kevin L.; Stefanson, Earl W.; Ahroon, William A.

    2017-01-01

    The National Institute for Occupational Safety and Health (NIOSH) sponsored tests of three earplug fit-test systems (NIOSH HPD Well-Fit™, Michael & Associates FitCheck, and Honeywell Safety Products VeriPRO®). Each system was compared to laboratory-based real-ear attenuation at threshold (REAT) measurements in a sound field according to ANSI/ASA S12.6-2008 at the NIOSH, Honeywell Safety Products, and Michael & Associates testing laboratories. An identical study was conducted independently at the U.S. Army Aeromedical Research Laboratory (USAARL), which provided their data for inclusion in this report. The Howard Leight Airsoft premolded earplug was tested with twenty subjects at each of the four participating laboratories. The occluded fit of the earplug was maintained during testing with a soundfield-based laboratory REAT system as well as all three headphone-based fit-test systems. The Michael & Associates lab had highest average A-weighted attenuations and smallest standard deviations. The NIOSH lab had the lowest average attenuations and the largest standard deviations. Differences in octave-band attenuations between each fit-test system and the American National Standards Institute (ANSI) sound field method were calculated (Attenfit-test - AttenANSI). A-weighted attenuations measured with FitCheck and HPD Well-Fit systems demonstrated approximately ±2 dB agreement with the ANSI sound field method, but A-weighted attenuations measured with the VeriPRO system underestimated the ANSI laboratory attenuations. For each of the fit-test systems, the average A-weighted attenuation across the four laboratories was not significantly greater than the average of the ANSI sound field method. Standard deviations for residual attenuation differences were about ±2 dB for FitCheck and HPD Well-Fit compared to ±4 dB for VeriPRO. Individual labs exhibited a range of agreement from less than a dB to as much as 9.4 dB difference with ANSI and REAT estimates. Factors such as

  8. 30 CFR 14.21 - Laboratory-scale flame test apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Laboratory-scale flame test apparatus. 14.21 Section 14.21 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING... Technical Requirements § 14.21 Laboratory-scale flame test apparatus. The principal parts of the apparatus...

  9. 30 CFR 14.21 - Laboratory-scale flame test apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Laboratory-scale flame test apparatus. 14.21 Section 14.21 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING... Technical Requirements § 14.21 Laboratory-scale flame test apparatus. The principal parts of the apparatus...

  10. 11. Interior view of control room in Components Test Laboratory ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. Interior view of control room in Components Test Laboratory (T-27), looking north. Photograph shows upgraded instrumentation, piping, and technological modifications installed in 1997-99 to accommodate component testing requirements for the Atlas V missile. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  11. 19 CFR 151.71 - Laboratory testing for clean yield.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.71... director. (b) Notification to importer. Where samples of wool or hair have been tested in a Customs... laboratory test is not feasible, the wool or hair may be retested by a commercial laboratory in accordance...

  12. 19 CFR 151.71 - Laboratory testing for clean yield.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.71... director. (b) Notification to importer. Where samples of wool or hair have been tested in a Customs... laboratory test is not feasible, the wool or hair may be retested by a commercial laboratory in accordance...

  13. 19 CFR 151.71 - Laboratory testing for clean yield.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.71... director. (b) Notification to importer. Where samples of wool or hair have been tested in a Customs... laboratory test is not feasible, the wool or hair may be retested by a commercial laboratory in accordance...

  14. 19 CFR 151.71 - Laboratory testing for clean yield.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.71... director. (b) Notification to importer. Where samples of wool or hair have been tested in a Customs... laboratory test is not feasible, the wool or hair may be retested by a commercial laboratory in accordance...

  15. 19 CFR 151.71 - Laboratory testing for clean yield.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.71... director. (b) Notification to importer. Where samples of wool or hair have been tested in a Customs... laboratory test is not feasible, the wool or hair may be retested by a commercial laboratory in accordance...

  16. 7 CFR 58.523 - Laboratory and quality control tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  17. 7 CFR 58.523 - Laboratory and quality control tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  18. 7 CFR 58.523 - Laboratory and quality control tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  19. 7 CFR 58.523 - Laboratory and quality control tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  20. 7 CFR 58.523 - Laboratory and quality control tests.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  1. 18. Interior view of HVAC room in Components Test Laboratory ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. Interior view of HVAC room in Components Test Laboratory (T-27), showing northwest corner. Photograph shows upgraded instrumentation, piping, and technological modifications for HVAC system installed in 1997-99 to accommodate component testing requirements for the Atlas V missile. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  2. 19. Interior view of HVAC room in Components Test Laboratory ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. Interior view of HVAC room in Components Test Laboratory (T-27), looking toward east wall. Photograph shows upgraded instrumentation, machinery, and technological modifications for HVAC system installed in 1997-99 to accommodate component testing requirements for the Atlas V missile. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  3. Closing the brain-to-brain loop in laboratory testing.

    PubMed

    Plebani, Mario; Lippi, Giuseppe

    2011-07-01

    Abstract The delivery of laboratory services has been described 40 years ago and defined with the foremost concept of "brain-to-brain turnaround time loop". This concept consists of several processes, including the final step which is the action undertaken on the patient based on laboratory information. Unfortunately, the need for systematic feedback to improve the value of laboratory services has been poorly understood and, even more risky, poorly applied in daily laboratory practice. Currently, major problems arise from the unavailability of consensually accepted quality specifications for the extra-analytical phase of laboratory testing. This, in turn, does not allow clinical laboratories to calculate a budget for the "patient-related total error". The definition and use of the term "total error" refers only to the analytical phase, and should be better defined as "total analytical error" to avoid any confusion and misinterpretation. According to the hierarchical approach to classify strategies to set analytical quality specifications, the "assessment of the effect of analytical performance on specific clinical decision-making" is comprehensively at the top and therefore should be applied as much as possible to address analytical efforts towards effective goals. In addition, an increasing number of laboratories worldwide are adopting risk management strategies such as FMEA, FRACAS, LEAN and Six Sigma since these techniques allow the identification of the most critical steps in the total testing process, and to reduce the patient-related risk of error. As a matter of fact, an increasing number of laboratory professionals recognize the importance of understanding and monitoring any step in the total testing process, including the appropriateness of the test request as well as the appropriate interpretation and utilization of test results.

  4. 5. AERIAL PHOTO OF THE COMPONENTS TEST LABORATORY DURING THE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. AERIAL PHOTO OF THE COMPONENTS TEST LABORATORY DURING THE CONSTRUCTION OF THE EAST TEST AREA. 1955, FRED ORDWAY COLLECTION, U.S. SPACE AND ROCKET CENTER, HUNTSVILLE, AL. - Marshall Space Flight Center, East Test Area, Components Test Laboratory, Huntsville, Madison County, AL

  5. Extracting laboratory test information from biomedical text

    PubMed Central

    Kang, Yanna Shen; Kayaalp, Mehmet

    2013-01-01

    Background: No previous study reported the efficacy of current natural language processing (NLP) methods for extracting laboratory test information from narrative documents. This study investigates the pathology informatics question of how accurately such information can be extracted from text with the current tools and techniques, especially machine learning and symbolic NLP methods. The study data came from a text corpus maintained by the U.S. Food and Drug Administration, containing a rich set of information on laboratory tests and test devices. Methods: The authors developed a symbolic information extraction (SIE) system to extract device and test specific information about four types of laboratory test entities: Specimens, analytes, units of measures and detection limits. They compared the performance of SIE and three prominent machine learning based NLP systems, LingPipe, GATE and BANNER, each implementing a distinct supervised machine learning method, hidden Markov models, support vector machines and conditional random fields, respectively. Results: Machine learning systems recognized laboratory test entities with moderately high recall, but low precision rates. Their recall rates were relatively higher when the number of distinct entity values (e.g., the spectrum of specimens) was very limited or when lexical morphology of the entity was distinctive (as in units of measures), yet SIE outperformed them with statistically significant margins on extracting specimen, analyte and detection limit information in both precision and F-measure. Its high recall performance was statistically significant on analyte information extraction. Conclusions: Despite its shortcomings against machine learning methods, a well-tailored symbolic system may better discern relevancy among a pile of information of the same type and may outperform a machine learning system by tapping into lexically non-local contextual information such as the document structure. PMID:24083058

  6. 10. Interior view of control room in Components Test Laboratory ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Interior view of control room in Components Test Laboratory (T-27), looking east. The control room is located in the center of the building and abuts the Test Cell 8, 9, and 10 and equipment room wings. Photograph shows upgraded instrumentation, piping, and technological modifications installed in 1997-99 to accommodate component testing requirements for the Atlas V missile. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  7. [Quality Management and Quality Specifications of Laboratory Tests in Clinical Studies--Challenges in Pre-Analytical Processes in Clinical Laboratories].

    PubMed

    Ishibashi, Midori

    2015-01-01

    The cost, speed, and quality are the three important factors recently indicated by the Ministry of Health, Labour and Welfare (MHLW) for the purpose of accelerating clinical studies. Based on this background, the importance of laboratory tests is increasing, especially in the evaluation of clinical study participants' entry and safety, and drug efficacy. To assure the quality of laboratory tests, providing high-quality laboratory tests is mandatory. For providing adequate quality assurance in laboratory tests, quality control in the three fields of pre-analytical, analytical, and post-analytical processes is extremely important. There are, however, no detailed written requirements concerning specimen collection, handling, preparation, storage, and shipping. Most laboratory tests for clinical studies are performed onsite in a local laboratory; however, a part of laboratory tests is done in offsite central laboratories after specimen shipping. As factors affecting laboratory tests, individual and inter-individual variations are well-known. Besides these factors, standardizing the factors of specimen collection, handling, preparation, storage, and shipping, may improve and maintain the high quality of clinical studies in general. Furthermore, the analytical method, units, and reference interval are also important factors. It is concluded that, to overcome the problems derived from pre-analytical processes, it is necessary to standardize specimen handling in a broad sense.

  8. Inter-laboratory validation of bioaccessibility testing for metals.

    PubMed

    Henderson, Rayetta G; Verougstraete, Violaine; Anderson, Kim; Arbildua, José J; Brock, Thomas O; Brouwers, Tony; Cappellini, Danielle; Delbeke, Katrien; Herting, Gunilla; Hixon, Greg; Odnevall Wallinder, Inger; Rodriguez, Patricio H; Van Assche, Frank; Wilrich, Peter; Oller, Adriana R

    2014-10-01

    Bioelution assays are fast, simple alternatives to in vivo testing. In this study, the intra- and inter-laboratory variability in bioaccessibility data generated by bioelution tests were evaluated in synthetic fluids relevant to oral, inhalation, and dermal exposure. Using one defined protocol, five laboratories measured metal release from cobalt oxide, cobalt powder, copper concentrate, Inconel alloy, leaded brass alloy, and nickel sulfate hexahydrate. Standard deviations of repeatability (sr) and reproducibility (sR) were used to evaluate the intra- and inter-laboratory variability, respectively. Examination of the sR:sr ratios demonstrated that, while gastric and lysosomal fluids had reasonably good reproducibility, other fluids did not show as good concordance between laboratories. Relative standard deviation (RSD) analysis showed more favorable reproducibility outcomes for some data sets; overall results varied more between- than within-laboratories. RSD analysis of sr showed good within-laboratory variability for all conditions except some metals in interstitial fluid. In general, these findings indicate that absolute bioaccessibility results in some biological fluids may vary between different laboratories. However, for most applications, measures of relative bioaccessibility are needed, diminishing the requirement for high inter-laboratory reproducibility in absolute metal releases. The inter-laboratory exercise suggests that the degrees of freedom within the protocol need to be addressed. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. 42 CFR 493.25 - Laboratories performing tests of high complexity.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Laboratories performing tests of high complexity. 493.25 Section 493.25 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND....25 Laboratories performing tests of high complexity. (a) A laboratory must obtain a certificate for...

  10. 42 CFR 493.25 - Laboratories performing tests of high complexity.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Laboratories performing tests of high complexity. 493.25 Section 493.25 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND....25 Laboratories performing tests of high complexity. (a) A laboratory must obtain a certificate for...

  11. Cruise Stage Testing for Mars Science Laboratory

    NASA Image and Video Library

    2010-09-02

    Testing of the cruise stage for NASA Mars Science Laboratory in August 2010 included a session in a facility that simulates the environment found in interplanetary space. Spacecraft technicians at JPL prepare a space-simulation test.

  12. 4. Exterior view of Components Test Laboratory (T27), looking northeast. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. Exterior view of Components Test Laboratory (T-27), looking northeast. The building wing on the left houses Test Cell 8 (oxidizer) and the oxidizer storage pit or vault, and that on the right houses Test Cell 10 (environmental). - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  13. 5. Exterior view of Components Test Laboratory (T27), looking northwest. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. Exterior view of Components Test Laboratory (T-27), looking northwest. The building wing on the left houses Test Cell 10 (environmental), and that on the right houses Test Cell 9 (fuel) and the fuel storage pit or vault. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  14. 42 CFR 493.25 - Laboratories performing tests of high complexity.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 5 2014-10-01 2014-10-01 false Laboratories performing tests of high complexity. 493.25 Section 493.25 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS General Provisions § 493.25 Laboratories performing tests of high...

  15. 42 CFR 493.20 - Laboratories performing tests of moderate complexity.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 5 2014-10-01 2014-10-01 false Laboratories performing tests of moderate complexity. 493.20 Section 493.20 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS General Provisions § 493.20 Laboratories performing tests of...

  16. Use of proficiency test performance to determine clinical laboratory director qualifications.

    PubMed

    Howanitz, P J

    1988-04-01

    Many activities and policies influence laboratory test quality. Proficiency test results are one measure of laboratory quality, and during the past 25 years, five studies have examined the relationship of laboratory director educational requirements to proficiency test results. Data from three studies support the association between director qualifications and quality as measured by proficiency test performance, whereas no relationship was found in the other two studies. Possible reasons for conflicting results include differences in database size and demographics; in addition, proficiency test results may be inappropriate, although widely used, as the sole measure of laboratory director performance.

  17. Shield evaluation and performance testing at the USMB`s Strategic Structures Testing Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barczak, T.M.; Gearhart, D.F.

    1996-12-31

    Historically, shield performance testing is conducted by the support manufacturers at European facilities. The U.S. Bureau of Mines (USBM) has conducted extensive research in shield Mechanics and is now opening its Strategic Structures Testing (SST) Laboratory to the mining industry for shield performance testing. The SST Laboratory provides unique shield testing capabilities using the Mine Roof Simulator (MRS) load frame. The MRS provides realistic and cost-effective shield evaluation by combining both vertical and horizontal loading into a single load cycle; whereas, several load cycles would be required to obtain this loading in a static frame. In addition to these advantages,more » the USBM acts as an independent research organization to provide an unbiased assessment of shield performance. This paper describes the USBM`s shield testing program that is designed specifically to simulate in-service mining conditions using the unique the capabilities of the SST Laboratory.« less

  18. 7 CFR 58.442 - Laboratory and quality control tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.442 Section... Service 1 Operations and Operating Procedures § 58.442 Laboratory and quality control tests. (a) Chemical... Methods or by other methods giving equivalent results. (b) Weight or volume control. Representative...

  19. 7 CFR 58.442 - Laboratory and quality control tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Laboratory and quality control tests. 58.442 Section... Service 1 Operations and Operating Procedures § 58.442 Laboratory and quality control tests. (a) Chemical... Methods or by other methods giving equivalent results. (b) Weight or volume control. Representative...

  20. Effect of Accreditation on Accuracy of Diagnostic Tests in Medical Laboratories

    PubMed Central

    Jang, Mi-Ae; Yoon, Young Ahn; Song, Junghan; Kim, Jeong-Ho; Min, Won-Ki; Lee, Ji Sung

    2017-01-01

    Background Medical laboratories play a central role in health care. Many laboratories are taking a more focused and stringent approach to quality system management. In Korea, laboratory standardization efforts undertaken by the Korean Laboratory Accreditation Program (KLAP) and the Korean External Quality Assessment Scheme (KEQAS) may have facilitated an improvement in laboratory performance, but there are no fundamental studies demonstrating that laboratory standardization is effective. We analyzed the results of the KEQAS to identify significant differences between laboratories with or without KLAP and to determine the impact of laboratory standardization on the accuracy of diagnostic tests. Methods We analyzed KEQAS participant data on clinical chemistry tests such as albumin, ALT, AST, and glucose from 2010 to 2013. As a statistical parameter to assess performance bias between laboratories, we compared 4-yr variance index score (VIS) between the two groups with or without KLAP. Results Compared with the group without KLAP, the group with KLAP exhibited significantly lower geometric means of 4-yr VIS for all clinical chemistry tests (P<0.0001); this difference justified a high level of confidence in standardized services provided by accredited laboratories. Confidence intervals for the mean of each test in the two groups (accredited and non-accredited) did not overlap, suggesting that the means of the groups are significantly different. Conclusions These results confirmed that practice standardization is strongly associated with the accuracy of test results. Our study emphasizes the necessity of establishing a system for standardization of diagnostic testing. PMID:28224767

  1. Effect of Accreditation on Accuracy of Diagnostic Tests in Medical Laboratories.

    PubMed

    Jang, Mi Ae; Yoon, Young Ahn; Song, Junghan; Kim, Jeong Ho; Min, Won Ki; Lee, Ji Sung; Lee, Yong Wha; Lee, You Kyoung

    2017-05-01

    Medical laboratories play a central role in health care. Many laboratories are taking a more focused and stringent approach to quality system management. In Korea, laboratory standardization efforts undertaken by the Korean Laboratory Accreditation Program (KLAP) and the Korean External Quality Assessment Scheme (KEQAS) may have facilitated an improvement in laboratory performance, but there are no fundamental studies demonstrating that laboratory standardization is effective. We analyzed the results of the KEQAS to identify significant differences between laboratories with or without KLAP and to determine the impact of laboratory standardization on the accuracy of diagnostic tests. We analyzed KEQAS participant data on clinical chemistry tests such as albumin, ALT, AST, and glucose from 2010 to 2013. As a statistical parameter to assess performance bias between laboratories, we compared 4-yr variance index score (VIS) between the two groups with or without KLAP. Compared with the group without KLAP, the group with KLAP exhibited significantly lower geometric means of 4-yr VIS for all clinical chemistry tests (P<0.0001); this difference justified a high level of confidence in standardized services provided by accredited laboratories. Confidence intervals for the mean of each test in the two groups (accredited and non-accredited) did not overlap, suggesting that the means of the groups are significantly different. These results confirmed that practice standardization is strongly associated with the accuracy of test results. Our study emphasizes the necessity of establishing a system for standardization of diagnostic testing. © The Korean Society for Laboratory Medicine

  2. Could light meal jeopardize laboratory coagulation tests?

    PubMed

    Lima-Oliveira, Gabriel; Salvagno, Gian Luca; Lippi, Giuseppe; Danese, Elisa; Gelati, Matteo; Montagnana, Martina; Picheth, Geraldo; Guidi, Gian Cesare

    2014-01-01

    Presently the necessity of fasting time for coagulation tests is not standardized. Our hypothesis is that this can harm patient safety. This study is aimed at evaluating whether a light meal (i.e. breakfast) can jeopardize laboratory coagulation tests. A blood sample was firstly collected from 17 fasting volunteers (12 h). Immediately after blood collection, the volunteers consumed a light meal. Then samples were collected at 1, 2 and 4 h after the meal. Coagulation tests included: activated partial thromboplastin time (APTT), prothrombin time (PT), fibrinogen (Fbg), antithrombin III (AT), protein C (PC) and protein S (PS). Differences between samples were assessed by Wilcoxon ranked-pairs test. The level of statistical significance was set at P < 0.05. Mean % differences were determined and differences between and baseline and 1, 2 and 4h samples were compared with reference change value (RCV). A significantly higher % activity of AT was observed at 1 h and 4 h after meal vs. baseline specimen [113 (104-117) and 111 (107-120) vs. 109 (102-118), respectively; P = 0.029 and P = 0.016]. APTT at 2 h was found significantly lower than baseline samples [32.0 (29.9-34.8) vs. 34.1 (32.2-35.2), respectively; P = 0.041]. The results of both Fbg and PS tests were not influenced by a light meal. Furthermore, no coagulation tests had significant variation after comparison with RCV. A light meal does not influence the laboratory coagulation tests we assessed, but we suggest that the laboratory quality managers standardize the fasting time for all blood tests at 12 hours, to completely metabolize the lipids intake.

  3. 42 CFR 414.508 - Payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 3 2010-10-01 2010-10-01 false Payment for a new clinical diagnostic laboratory... SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.508 Payment for a new clinical diagnostic laboratory test. For a new clinical diagnostic laboratory test that is assigned a new or...

  4. 42 CFR 414.508 - Payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 3 2011-10-01 2011-10-01 false Payment for a new clinical diagnostic laboratory... SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.508 Payment for a new clinical diagnostic laboratory test. For a new clinical diagnostic laboratory test that is assigned a new or...

  5. 2. Exterior view of Components Test Laboratory (T27), looking southeast. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Exterior view of Components Test Laboratory (T-27), looking southeast. The building wing on the left houses the equipment room and that on the right houses Test Cell 8 (oxidizer) and the oxidizer storage pit or vault. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  6. 3. Exterior view of Components Test Laboratory (T27), looking southeast. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. Exterior view of Components Test Laboratory (T-27), looking southeast. The building wing on the left houses the equipment room, and that on the right houses Test Cell 8 (oxidizer) and the oxidizer storage pit or vault. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  7. Parachute Testing for Mars Science Laboratory

    NASA Image and Video Library

    2007-12-20

    The team developing the landing system for NASA Mars Science Laboratory tested the deployment of an early parachute design in mid-October 2007 inside the world largest wind tunnel, at NASA Ames Research Center, Moffett Field, California.

  8. Airborne Proximity Warning Instrument Laboratory Tests

    DOT National Transportation Integrated Search

    1977-01-01

    An Airborne Proximity Warning Instrument (APWI) designed and manufactured by Rock Avionics, New York, was subjected to a short laboratory test at the Transportation Systems Center to determine the suitability of this product for further evaluation as...

  9. Are laboratory tests always needed? Frequency and causes of laboratory overuse in a hospital setting.

    PubMed

    Cadamuro, Janne; Gaksch, Martin; Wiedemann, Helmut; Lippi, Giuseppe; von Meyer, Alexander; Pertersmann, Astrid; Auer, Simon; Mrazek, Cornelia; Kipman, Ulrike; Felder, Thomas K; Oberkofler, Hannes; Haschke-Becher, Elisabeth

    2018-04-01

    Inappropriate utilization of laboratory resources is an increasing concern especially in high-throughput facilities. Until now, no reliable information has been published addressing to which extent laboratory results are actually used for clinical decision-making. Therefore, we aimed to close this gap using a novel retrospective approach including a survey of clinicians and nurses. We retrospectively evaluated the number of re-orders for potassium (K), lactate dehydrogenase (LD), aspartate-aminotransferase (AST), activated partial thromboplastin-time (APTT) and prothrombin-time/INR (PT/INR), after the initial order had to be cancelled due to preanalytical non-conformities. We analyzed subgroups regarding time to re-order, ward and sample priority (urgent vs. routine). Subsequently, we surveyed clinicians and nurses, asking for their estimate of the amount of failed re-orders as well as for possible reasons. From initially cancelled tests, only ~20% of K, LD, AST and ~30% of APTT and PT/INR tests were re-ordered within 24 h. 70% of the investigated clinical chemistry and 60% of coagulation tests were re-ordered one week after cancellation or not at all. Survey participants quite accurately estimated these numbers. Routine laboratory panels, short stay of out-patients, obsolete test results and avoiding additional phlebotomies were the main reasons for not re-ordering cancelled tests. Overall, 60-70% of test results in the investigated assays ordered in a high throughput laboratory are potentially inappropriate or of doubtful clinically importance. Although clinicians and nurses are aware of this situation, it is the duty of laboratory specialists to overcome overutilization in close collaboration with all involved healthcare workers. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  10. Towards a rational antimicrobial testing policy in the laboratory.

    PubMed

    Banaji, N; Oommen, S

    2011-01-01

    Antimicrobial policy for prophylactic and therapeutic use of antimicrobials in a tertiary care setting has gained importance. A hospital's antimicrobial policy as laid down by its hospital infection control team needs to include inputs from the microbiology laboratory, besides the pharmacy and therapeutic committee. Therefore, it is of utmost importance that clinical microbiologists across India follow international guidelines and also take into account local settings, especially detection and presence of resistance enzymes. This article draws a framework for rational antimicrobial testing in our laboratories in tertiary care centers, from the Clinical and Laboratory Standards Institute guidelines. It does not address testing methodologies but suggests ways and means by which antimicrobial susceptibility reporting can be rendered meaningful not only to the treating physician but also to the resistance monitoring epidemiologist. It hopes to initiate some standardization in rational choice of antimicrobial testing in laboratories in the country pertaining to nonfastidious bacteria.

  11. 7. Exterior view of Components Test Laboratory (T27), looking south. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. Exterior view of Components Test Laboratory (T-27), looking south. The wing in the immediate foreground houses the equipment room. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  12. Laboratory or Field Tests for Evaluating Firefighters' Work Capacity?

    PubMed Central

    Lindberg, Ann-Sofie; Oksa, Juha; Malm, Christer

    2014-01-01

    Muscle strength is important for firefighters work capacity. Laboratory tests used for measurements of muscle strength, however, are complicated, expensive and time consuming. The aims of the present study were to investigate correlations between physical capacity within commonly occurring and physically demanding firefighting work tasks and both laboratory and field tests in full time (N = 8) and part-time (N = 10) male firefighters and civilian men (N = 8) and women (N = 12), and also to give recommendations as to which field tests might be useful for evaluating firefighters' physical work capacity. Laboratory tests of isokinetic maximal (IM) and endurance (IE) muscle power and dynamic balance, field tests including maximal and endurance muscle performance, and simulated firefighting work tasks were performed. Correlations with work capacity were analyzed with Spearman's rank correlation coefficient (rs). The highest significant (p<0.01) correlations with laboratory and field tests were for Cutting: IE trunk extension (rs = 0.72) and maximal hand grip strength (rs = 0.67), for Stairs: IE shoulder flexion (rs = −0.81) and barbell shoulder press (rs = −0.77), for Pulling: IE shoulder extension (rs = −0.82) and bench press (rs = −0.85), for Demolition: IE knee extension (rs = 0.75) and bench press (rs = 0.83), for Rescue: IE shoulder flexion (rs = −0.83) and bench press (rs = −0.82), and for the Terrain work task: IE trunk flexion (rs = −0.58) and upright barbell row (rs = −0.70). In conclusion, field tests may be used instead of laboratory tests. Maximal hand grip strength, bench press, chin ups, dips, upright barbell row, standing broad jump, and barbell shoulder press were strongly correlated (rs≥0.7) with work capacity and are therefore recommended for evaluating firefighters work capacity. PMID:24614596

  13. Laboratory or field tests for evaluating firefighters' work capacity?

    PubMed

    Lindberg, Ann-Sofie; Oksa, Juha; Malm, Christer

    2014-01-01

    Muscle strength is important for firefighters work capacity. Laboratory tests used for measurements of muscle strength, however, are complicated, expensive and time consuming. The aims of the present study were to investigate correlations between physical capacity within commonly occurring and physically demanding firefighting work tasks and both laboratory and field tests in full time (N = 8) and part-time (N = 10) male firefighters and civilian men (N = 8) and women (N = 12), and also to give recommendations as to which field tests might be useful for evaluating firefighters' physical work capacity. Laboratory tests of isokinetic maximal (IM) and endurance (IE) muscle power and dynamic balance, field tests including maximal and endurance muscle performance, and simulated firefighting work tasks were performed. Correlations with work capacity were analyzed with Spearman's rank correlation coefficient (rs). The highest significant (p<0.01) correlations with laboratory and field tests were for Cutting: IE trunk extension (rs = 0.72) and maximal hand grip strength (rs = 0.67), for Stairs: IE shoulder flexion (rs = -0.81) and barbell shoulder press (rs = -0.77), for Pulling: IE shoulder extension (rs = -0.82) and bench press (rs = -0.85), for Demolition: IE knee extension (rs = 0.75) and bench press (rs = 0.83), for Rescue: IE shoulder flexion (rs = -0.83) and bench press (rs = -0.82), and for the Terrain work task: IE trunk flexion (rs = -0.58) and upright barbell row (rs = -0.70). In conclusion, field tests may be used instead of laboratory tests. Maximal hand grip strength, bench press, chin ups, dips, upright barbell row, standing broad jump, and barbell shoulder press were strongly correlated (rs≥0.7) with work capacity and are therefore recommended for evaluating firefighters work capacity.

  14. The role of laboratory in ensuring appropriate test requests.

    PubMed

    Ferraro, Simona; Panteghini, Mauro

    2017-07-01

    This review highlights the role of laboratory professionals and the strategies to be promoted in strict cooperation with clinicians for auditing, monitoring and improving the appropriateness of test request. The introduction of local pathways and care maps in agreement with international and national guidelines as well as the implementation of reflex testing and algorithms have a central role in guiding test request and in correcting the overuse/misuse of tests. Furthermore, removing obsolete tests from laboratory menu and vetting of restricted tests is recommended to increase cost-effectiveness. This saves costs and permits to introduce new biomarkers with increased diagnostic accuracy with a better impact on patient outcome. An additional issue is concerning the periodicity of (re)testing, accounting that only a minority of tests may be ordered as often as necessary. In the majority of cases, a minimum retesting interval should be introduced. The availability of effective computerised order entry systems is relevant in ensuring appropriate test requests and in providing an aid by automated rules that may stop inappropriate requests before they reach the laboratory. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  15. Diagnosis of canine hypothyroidism. Perspectives from a testing laboratory.

    PubMed

    Kemppainen, R J; Behrend, E N

    2001-09-01

    The most common sample received by our endocrine testing laboratory is submitted for the diagnosis of hypothyroidism in a dog. The current tests most frequently employed in our laboratory for thyroid evaluation in dogs are total T4, free T4 by dialysis, and canine TSH measurement. Each test has strengths and weaknesses and suffers from the possibility of both false positive and false negative results. This article provides a working description of each test and an approach to interpretation of results. Other tests that are less commonly used are also discussed. Examples of interpretation of test results in individual hypothyroid-suspect dogs are presented for illustration.

  16. 49 CFR 40.81 - What laboratories may be used for DOT drug testing?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false What laboratories may be used for DOT drug testing... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.81 What laboratories may be used for DOT drug testing? (a) As a drug testing laboratory located in the U.S., you are...

  17. 49 CFR 40.81 - What laboratories may be used for DOT drug testing?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 1 2012-10-01 2012-10-01 false What laboratories may be used for DOT drug testing... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.81 What laboratories may be used for DOT drug testing? (a) As a drug testing laboratory located in the U.S., you are...

  18. 49 CFR 40.81 - What laboratories may be used for DOT drug testing?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 1 2014-10-01 2014-10-01 false What laboratories may be used for DOT drug testing... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.81 What laboratories may be used for DOT drug testing? (a) As a drug testing laboratory located in the U.S., you are...

  19. 49 CFR 40.81 - What laboratories may be used for DOT drug testing?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 1 2013-10-01 2013-10-01 false What laboratories may be used for DOT drug testing... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.81 What laboratories may be used for DOT drug testing? (a) As a drug testing laboratory located in the U.S., you are...

  20. 49 CFR 40.81 - What laboratories may be used for DOT drug testing?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false What laboratories may be used for DOT drug testing... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.81 What laboratories may be used for DOT drug testing? (a) As a drug testing laboratory located in the U.S., you are...

  1. NASA Glenn's Acoustical Testing Laboratory Awarded Accreditation by the National Voluntary Laboratory Accreditation Program

    NASA Technical Reports Server (NTRS)

    Akers, James C.; Cooper, Beth A.

    2004-01-01

    NASA Glenn Research Center's Acoustical Testing Laboratory (ATL) provides a comprehensive array of acoustical testing services, including sound pressure level, sound intensity level, and sound-power-level testing per International Standards Organization (ISO)1 3744. Since its establishment in September 2000, the ATL has provided acoustic emission testing and noise control services for a variety of customers, particularly microgravity space flight hardware that must meet International Space Station acoustic emission requirements. The ATL consists of a 23- by 27- by 20-ft (height) convertible hemi/anechoic test chamber and a separate sound-attenuating test support enclosure. The ATL employs a personal-computer-based data acquisition system that provides up to 26 channels of simultaneous data acquisition with real-time analysis (ref. 4). Specialized diagnostic tools, including a scanning sound-intensity system, allow the ATL's technical staff to support its clients' aggressive low-noise design efforts to meet the space station's acoustic emission requirement. From its inception, the ATL has pursued the goal of developing a comprehensive ISO 17025-compliant quality program that would incorporate Glenn's existing ISO 9000 quality system policies as well as ATL-specific technical policies and procedures. In March 2003, the ATL quality program was awarded accreditation by the National Voluntary Laboratory Accreditation Program (NVLAP) for sound-power-level testing in accordance with ISO 3744. The NVLAP program is administered by the National Institutes of Standards and Technology (NIST) of the U.S. Department of Commerce and provides third-party accreditation for testing and calibration laboratories. There are currently 24 NVLAP-accredited acoustical testing laboratories in the United States. NVLAP accreditation covering one or more specific testing procedures conducted in accordance with established test standards is awarded upon successful completion of an intensive

  2. 7 CFR 3300.91 - List of approved testing stations, approved testing laboratories, and fees for certificates.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... CARRIAGE OF PERISHABLE FOODSTUFFS AND ON THE SPECIAL EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP... testing stations, approved testing laboratories, and fees for certificates. A current list of U.S. ATP testing stations, U.S. ATP testing laboratories, and fees for issuance of U.S. ATP certificates may be...

  3. 7 CFR 3300.91 - List of approved testing stations, approved testing laboratories, and fees for certificates.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... CARRIAGE OF PERISHABLE FOODSTUFFS AND ON THE SPECIAL EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP... testing stations, approved testing laboratories, and fees for certificates. A current list of U.S. ATP testing stations, U.S. ATP testing laboratories, and fees for issuance of U.S. ATP certificates may be...

  4. 7 CFR 3300.91 - List of approved testing stations, approved testing laboratories, and fees for certificates.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... CARRIAGE OF PERISHABLE FOODSTUFFS AND ON THE SPECIAL EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP... testing stations, approved testing laboratories, and fees for certificates. A current list of U.S. ATP testing stations, U.S. ATP testing laboratories, and fees for issuance of U.S. ATP certificates may be...

  5. 7 CFR 3300.91 - List of approved testing stations, approved testing laboratories, and fees for certificates.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... CARRIAGE OF PERISHABLE FOODSTUFFS AND ON THE SPECIAL EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP... testing stations, approved testing laboratories, and fees for certificates. A current list of U.S. ATP testing stations, U.S. ATP testing laboratories, and fees for issuance of U.S. ATP certificates may be...

  6. 7 CFR 3300.91 - List of approved testing stations, approved testing laboratories, and fees for certificates.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... CARRIAGE OF PERISHABLE FOODSTUFFS AND ON THE SPECIAL EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP... testing stations, approved testing laboratories, and fees for certificates. A current list of U.S. ATP testing stations, U.S. ATP testing laboratories, and fees for issuance of U.S. ATP certificates may be...

  7. Financial incentives and the supply of laboratory tests.

    PubMed

    Carlsen, Fredrik; Grytten, Jostein; Skau, Irene

    2003-11-01

    This study examined how the number of laboratory tests taken by a sample of Norwegian contract physicians is influenced by their private economy outside of the practice and by changes in remuneration. The data are drawn from 40,000 consultations carried out by 44 contract physicians in 1991-1994. Two factors which led to changes in the level of physicians' income are considered: changes in remuneration for consultations and laboratory tests and changes in interest rates on loans and bank deposits. The effect which changes in interest rates have on physicians' disposable income was calculated using information about their financial assets and debts obtained from tax assessments. The main finding was that changes in private economy and changes in remuneration have no or only a small effect on the number of laboratory tests taken. Our results suggest that fee regulation can be an effective means of controlling physicians' income and therefore government expenditure on primary physician services.

  8. The Tanzania experience: clinical laboratory testing harmonization and equipment standardization at different levels of a tiered health laboratory system.

    PubMed

    Massambu, Charles; Mwangi, Christina

    2009-06-01

    The rapid scale-up of the care and treatment programs in Tanzania during the preceding 4 years has greatly increased the demand for quality laboratory services for diagnosis of HIV and monitoring patients during antiretroviral therapy. Laboratory services were not in a position to cope with this demand owing to poor infrastructure, lack of human resources, erratic and/or lack of reagent supply and commodities, and slow manual technologies. With the limited human resources in the laboratory and the need for scaling up the care and treatment program, it became necessary to install automated equipment and train personnel for the increased volume of testing and new tests across all laboratory levels. With the numerous partners procuring equipment, the possibility of a multitude of equipment platforms with attendant challenges for procurement of reagents, maintenance of equipment, and quality assurance arose. Tanzania, therefore, had to harmonize laboratory tests and standardize laboratory equipment at different levels of the laboratory network. The process of harmonization of tests and standardization of equipment included assessment of laboratories, review of guidelines, development of a national laboratory operational plan, and stakeholder advocacy. This document outlines this process.

  9. Quality assurance of laboratory work and clinical use of laboratory tests in general practice in norway: a survey.

    PubMed

    Thue, Geir; Jevnaker, Marianne; Gulstad, Guri Andersen; Sandberg, Sverre

    2011-09-01

    Virtually all the general practices in Norway participate in the Norwegian Quality Improvement of Laboratory Services in Primary Care, NOKLUS. In order to assess and develop NOKLUS's services, it was decided to carry out an investigation in the largest participating group, general practices. In autumn 2008 a questionnaire was sent to all Norwegian general practices asking for feedback on different aspects of NOKLUS's main services: contact with medical laboratory technologists, sending of control materials, use and maintenance of practice-specific laboratory binders, courses, and testing of laboratory equipment. In addition, attitudes were elicited towards possible new services directed at assessing other technical equipment and clinical use of tests. Responses were received from 1290 of 1552 practices (83%). The great majority thought that the frequency of sending out control material should continue as at present, and they were pleased with the feedback reports and follow-up by the laboratory technologists in the counties. Even after many years of practical experience, there is still a need to update laboratory knowledge through visits to practices, courses, and written information. Practices also wanted quality assurance of blood pressure meters and spirometers, and many doctors wanted feedback on their use of laboratory tests. Services regarding quality assurance of point-of-care tests, guidance, and courses should be continued. Quality assurance of other technical equipment and of the doctor's clinical use of laboratory tests should be established as part of comprehensive quality assurance.

  10. Automated cognitive testing of monkeys in social groups yields results comparable to individual laboratory-based testing.

    PubMed

    Gazes, Regina Paxton; Brown, Emily Kathryn; Basile, Benjamin M; Hampton, Robert R

    2013-05-01

    Cognitive abilities likely evolved in response to specific environmental and social challenges and are therefore expected to be specialized for the life history of each species. Specialized cognitive abilities may be most readily engaged under conditions that approximate the natural environment of the species being studied. While naturalistic environments might therefore have advantages over laboratory settings for cognitive research, it is difficult to conduct certain types of cognitive tests in these settings. We implemented methods for automated cognitive testing of monkeys (Macaca mulatta) in large social groups (Field station) and compared the performance to that of laboratory-housed monkeys (Laboratory). The Field station animals shared access to four touch-screen computers in a large naturalistic social group. Each Field station subject had an RFID chip implanted in each arm for computerized identification and individualized assignment of cognitive tests. The Laboratory group was housed and tested in a typical laboratory setting, with individual access to testing computers in their home cages. Monkeys in both groups voluntarily participated at their own pace for food rewards. We evaluated performance in two visual psychophysics tests, a perceptual classification test, a transitive inference test, and a delayed matching-to-sample memory test. Despite the differences in housing, social environment, age, and sex, monkeys in the two groups performed similarly in all tests. Semi-free ranging monkeys living in complex social environments are therefore viable subjects for cognitive testing designed to take advantage of the unique affordances of naturalistic testing environments.

  11. Automated cognitive testing of monkeys in social groups yields results comparable to individual laboratory based testing

    PubMed Central

    Gazes, Regina Paxton; Brown, Emily Kathryn; Basile, Benjamin M.; Hampton, Robert R.

    2013-01-01

    Cognitive abilities likely evolved in response to specific environmental and social challenges and are therefore expected to be specialized for the life history of each species. Specialized cognitive abilities may be most readily engaged under conditions that approximate the natural environment of the species being studied. While naturalistic environments might therefore have advantages over laboratory settings for cognitive research, it is difficult to conduct certain types of cognitive tests in these settings. We implemented methods for automated cognitive testing of monkeys (Macaca mulatta) in large social groups (Field station) and compared the performance to that of laboratory housed monkeys (Laboratory). The Field station animals shared access to four touch screen computers in a large naturalistic social group. Each Field station subject had an RFID chip implanted in each arm for computerized identification and individualized assignment of cognitive tests. The Laboratory group was housed and tested in a typical laboratory setting, with individual access to testing computers in their home cages. Monkeys in both groups voluntarily participated at their own pace for food rewards. We evaluated performance in two visual psychophysics tests, a perceptual classification test, a transitive inference test, and a delayed matching to sample memory test. Despite differences in housing, social environment, age, and sex, monkeys in the two groups performed similarly in all tests. Semi-free ranging monkeys living in complex social environments are therefore viable subjects for cognitive testing designed to take advantage of the unique affordances of naturalistic testing environments. PMID:23263675

  12. 9 CFR 590.580 - Laboratory tests and analyses.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 2 2014-01-01 2014-01-01 false Laboratory tests and analyses. 590.580 Section 590.580 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE... sequence, frequency, and approved laboratory methods as prescribed by the AMS Science Division Director...

  13. 9 CFR 590.580 - Laboratory tests and analyses.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 2 2013-01-01 2013-01-01 false Laboratory tests and analyses. 590.580 Section 590.580 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE... sequence, frequency, and approved laboratory methods as prescribed by the AMS Science Division Director...

  14. 9 CFR 590.580 - Laboratory tests and analyses.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 2 2012-01-01 2012-01-01 false Laboratory tests and analyses. 590.580 Section 590.580 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE... sequence, frequency, and approved laboratory methods as prescribed by the AMS Science Division Director...

  15. Exploration of task performance tests in a physics laboratory

    NASA Astrophysics Data System (ADS)

    Liu, Dan; El Turkey, Houssein

    2017-11-01

    In this article, we investigate the implementation of task performance tests in an undergraduate physics laboratory. Two performance tests were carried out over two semesters using the task of building a DC circuit. The first implementation in Spring 2014 had certain concerns such as the privacy of students’ testing and their ‘trial and error’ attempts. These concerns were addressed in Fall 2015 through implementing a second performance test. The second implementation was administered differently but the content of the two tests was the same. We discuss the validity of both implementations and present the correlation (or lack of) between the time that students needed to complete the tests and their grades from a paper-based laboratory assessment method.

  16. 49 CFR 40.99 - How long does the laboratory retain specimens after testing?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... after testing? 40.99 Section 40.99 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.99 How long does the laboratory retain specimens after testing? (a) As a laboratory testing the primary...

  17. 49 CFR 40.99 - How long does the laboratory retain specimens after testing?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... after testing? 40.99 Section 40.99 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.99 How long does the laboratory retain specimens after testing? (a) As a laboratory testing the primary...

  18. 49 CFR 40.99 - How long does the laboratory retain specimens after testing?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... after testing? 40.99 Section 40.99 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.99 How long does the laboratory retain specimens after testing? (a) As a laboratory testing the primary...

  19. 49 CFR 40.99 - How long does the laboratory retain specimens after testing?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... after testing? 40.99 Section 40.99 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.99 How long does the laboratory retain specimens after testing? (a) As a laboratory testing the primary...

  20. 49 CFR 40.99 - How long does the laboratory retain specimens after testing?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... after testing? 40.99 Section 40.99 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.99 How long does the laboratory retain specimens after testing? (a) As a laboratory testing the primary...

  1. Trends in laboratory test volumes for Medicare Part B reimbursements, 2000-2010.

    PubMed

    Shahangian, Shahram; Alspach, Todd D; Astles, J Rex; Yesupriya, Ajay; Dettwyler, William K

    2014-02-01

    Changes in reimbursements for clinical laboratory testing may help us assess the effect of various variables, such as testing recommendations, market forces, changes in testing technology, and changes in clinical or laboratory practices, and provide information that can influence health care and public health policy decisions. To date, however, there has been no report, to our knowledge, of longitudinal trends in national laboratory test use. To evaluate Medicare Part B-reimbursed volumes of selected laboratory tests per 10,000 enrollees from 2000 through 2010. Laboratory test reimbursement volumes per 10,000 enrollees in Medicare Part B were obtained from the Centers for Medicare & Medicaid Services (Baltimore, Maryland). The ratio of the most recent (2010) reimbursed test volume per 10,000 Medicare enrollees, divided by the oldest data (usually 2000) during this decade, called the volume ratio, was used to measure trends in test reimbursement. Laboratory tests with a reimbursement claim frequency of at least 10 per 10,000 Medicare enrollees in 2010 were selected, provided there was more than a 50% change in test reimbursement volume during the 2000-2010 decade. We combined the reimbursed test volumes for the few tests that were listed under more than one code in the Current Procedural Terminology (American Medical Association, Chicago, Illinois). A 2-sided Poisson regression, adjusted for potential overdispersion, was used to determine P values for the trend; trends were considered significant at P < .05. Tests with the greatest decrease in reimbursement volumes were electrolytes, digoxin, carbamazepine, phenytoin, and lithium, with volume ratios ranging from 0.27 to 0.64 (P < .001). Tests with the greatest increase in reimbursement volumes were meprobamate, opiates, methadone, phencyclidine, amphetamines, cocaine, and vitamin D, with volume ratios ranging from 83 to 1510 (P < .001). Although reimbursement volumes increased for most of the selected tests, other

  2. Good laboratory practices for biochemical genetic testing and newborn screening for inherited metabolic disorders.

    PubMed

    2012-04-06

    Biochemical genetic testing and newborn screening are essential laboratory services for the screening, detection, diagnosis, and monitoring of inborn errors of metabolism or inherited metabolic disorders. Under the Clinical Laboratory Improvement Amendments of 1988 (CLIA) regulations, laboratory testing is categorized on the basis of the level of testing complexity as either waived (i.e., from routine regulatory oversight) or nonwaived testing (which includes tests of moderate and high complexity). Laboratories that perform biochemical genetic testing are required by CLIA regulations to meet the general quality systems requirements for nonwaived testing and the personnel requirements for high-complexity testing. Laboratories that perform public health newborn screening are subject to the same CLIA regulations and applicable state requirements. As the number of inherited metabolic diseases that are included in state-based newborn screening programs continues to increase, ensuring the quality of performance and delivery of testing services remains a continuous challenge not only for public health laboratories and other newborn screening facilities but also for biochemical genetic testing laboratories. To help ensure the quality of laboratory testing, CDC collaborated with the Centers for Medicare & Medicaid Services, the Food and Drug Administration, the Health Resources and Services Administration, and the National Institutes of Health to develop guidelines for laboratories to meet CLIA requirements and apply additional quality assurance measures for these areas of genetic testing. This report provides recommendations for good laboratory practices that were developed based on recommendations from the Clinical Laboratory Improvement Advisory Committee, with additional input from the Secretary's Advisory Committee on Genetics, Health, and Society; the Secretary's Advisory Committee on Heritable Disorders in Newborns and Children; and representatives of newborn

  3. Use of laboratory testing for genital chlamydial infection in Norway.

    PubMed Central

    Aavitsland, P

    1993-01-01

    OBJECTIVE--To assess the use of laboratory tests for genital chlamydial infection in Norway. DESIGN--Questionnaire survey of general practitioners' practice in chlamydial testing, retrospective survey of laboratory records, 1986-91, and prospective study of testing in one laboratory during four weeks. SETTING--All 18 microbiological laboratories in Norway (4.2 million population), including one serving all doctors in Vestfold county (0.2 million population). SUBJECTS--302 general practitioners. MAIN MEASURES--GPs' routine practice, methods used for testing, 1986-91, and sex specific and age group specific testing in 1991. RESULTS--201(69%) GPs replied to the questionnaire: 101(51%) would test all women younger than 25 years at routine pelvic examination, 107(54%) all girls at first pelvic examination, 131(66%) all pregnant women, and 106(54%) all men whose female partner had urogenital complaints. Nationwide in 1986, 122,000 tests were performed (2.9 per 100 population); 10% were positive and 51% were cell culture tests. In 1991, 341,000 tests were performed (8.0 per 100 population); 4.5% were positive and 15% were cell culture tests. 13,184 tests were performed in Vestfold in 1991 (6.6 per 100 population). The age group specific rates (per 100 population) among women were: age 15-19 years, 22.0(95% confidence interval 18.2 to 25.8); 20-24 years, 47.2(42.1 to 52.3); 25-29 years, 42.3(37.1 to 47.5); 30-34 years, 29.8(25.4 to 34.2); and 35-39 years, 12.5(9.5 to 15.5). CONCLUSIONS--GPs use liberal indications for testing. The dramatic increase in testing, especially by enzyme immunoassays, in populations with a low prevalence of infection results in low cost effectiveness and low predictive value of positive tests, which in women over 29 years is estimated as 17-36%. IMPLICATIONS--Doctors should be educated about the limitations of enzyme immunoassays in screening low prevalence populations, and laboratories should apply a confirmatory test to specimens testing

  4. Laboratory Testing Protocols for Heparin-Induced Thrombocytopenia (HIT) Testing.

    PubMed

    Lau, Kun Kan Edwin; Mohammed, Soma; Pasalic, Leonardo; Favaloro, Emmanuel J

    2017-01-01

    Heparin-induced thrombocytopenia (HIT) represents a significant high morbidity complication of heparin therapy. The clinicopathological diagnosis of HIT remains challenging for many reasons; thus, laboratory testing represents an important component of an accurate diagnosis. Although there are many assays available to assess HIT, these essentially fall into two categories-(a) immunological assays, and (b) functional assays. The current chapter presents protocols for several HIT assays, being those that are most commonly performed in laboratory practice and have the widest geographic distribution. These comprise a manual lateral flow-based system (STiC), a fully automated latex immunoturbidimetric assay, a fully automated chemiluminescent assay (CLIA), light transmission aggregation (LTA), and whole blood aggregation (Multiplate).

  5. Constrained Laboratory vs. Unconstrained Steering-Induced Rollover Crash Tests.

    PubMed

    Kerrigan, Jason R; Toczyski, Jacek; Roberts, Carolyn; Zhang, Qi; Clauser, Mark

    2015-01-01

    The goal of this study was to evaluate how well an in-laboratory rollover crash test methodology that constrains vehicle motion can reproduce the dynamics of unconstrained full-scale steering-induced rollover crash tests in sand. Data from previously-published unconstrained steering-induced rollover crash tests using a full-size pickup and mid-sized sedan were analyzed to determine vehicle-to-ground impact conditions and kinematic response of the vehicles throughout the tests. Then, a pair of replicate vehicles were prepared to match the inertial properties of the steering-induced test vehicles and configured to record dynamic roof structure deformations and kinematic response. Both vehicles experienced greater increases in roll-axis angular velocities in the unconstrained tests than in the constrained tests; however, the increases that occurred during the trailing side roof interaction were nearly identical between tests for both vehicles. Both vehicles experienced linear accelerations in the constrained tests that were similar to those in the unconstrained tests, but the pickup, in particular, had accelerations that were matched in magnitude, timing, and duration very closely between the two test types. Deformations in the truck test were higher in the constrained than the unconstrained, and deformations in the sedan were greater in the unconstrained than the constrained as a result of constraints of the test fixture, and differences in impact velocity for the trailing side. The results of the current study suggest that in-laboratory rollover tests can be used to simulate the injury-causing portions of unconstrained rollover crashes. To date, such a demonstration has not yet been published in the open literature. This study did, however, show that road surface can affect vehicle response in a way that may not be able to be mimicked in the laboratory. Lastly, this study showed that configuring the in-laboratory tests to match the leading-side touchdown conditions

  6. Good Laboratory Practices of Materials Testing at NASA White Sands Test Facility

    NASA Technical Reports Server (NTRS)

    Hirsch, David; Williams, James H.

    2005-01-01

    An approach to good laboratory practices of materials testing at NASA White Sands Test Facility is presented. The contents include: 1) Current approach; 2) Data analysis; and 3) Improvements sought by WSTF to enhance the diagnostic capability of existing methods.

  7. 42 CFR 493.1421 - Condition: Laboratories performing moderate complexity testing; testing personnel.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing moderate complexity testing; testing personnel. 493.1421 Section 493.1421 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION...

  8. 42 CFR 493.1421 - Condition: Laboratories performing moderate complexity testing; testing personnel.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Laboratories performing moderate complexity testing; testing personnel. 493.1421 Section 493.1421 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION...

  9. Syphilis testing in antenatal care: Policies and practices among laboratories in the Americas.

    PubMed

    Luu, Minh; Ham, Cal; Kamb, Mary L; Caffe, Sonja; Hoover, Karen W; Perez, Freddy

    2015-06-01

    To asses laboratory syphilis testing policies and practices among laboratories in the Americas. Laboratory directors or designees from PAHO member countries were invited to participate in a structured, electronically-delivered survey between March and August, 2014. Data on syphilis tests, algorithms, and quality control (QC) practices were analyzed, focusing on laboratories receiving specimens from antenatal clinics (ANCs). Surveys were completed by 69 laboratories representing 30 (86%) countries. Participating laboratories included 36 (52%) national or regional reference labs and 33 (48%) lower-level laboratories. Most (94%) were public sector facilities and 71% reported existence of a national algorithm for syphilis testing in pregnancy, usually involving both treponemal and non-treponemal testing (72%). Less than half (41%) used rapid syphilis tests (RSTs); and only seven laboratories representing five countries reported RSTs were included in the national algorithm for pregnant women. Most (83%) laboratories serving ANCs reported using some type of QC system; 68% of laboratories reported participation in external QC. Only 36% of laboratories reported data to national/local surveillance. Half of all laboratories serving ANC settings reported a stockout of one or more essential supplies during the previous year (median duration, 30days). Updating laboratory algorithms, improving testing standards, integrating data into existing surveillance, and improved procurement and distribution of commodities may be needed to ensure elimination of MTCT of syphilis in the Americas. Copyright © 2015. Published by Elsevier Ireland Ltd.

  10. [Point-of-care-testing--the intensive care laboratory].

    PubMed

    Müller, M M; Hackl, W; Griesmacher, A

    1999-01-01

    After successful centralization of laboratory analyses since more than 30 years, advances in biosensors, microprocessors, measurement of undiluted whole blood and miniaturization of laboratory analyzers are leading nowadays more and more to a re-decentralization in the laboratory medicine. Point-of-care-testing (POCT), which is defined as any laboratory test performed outside central or decentralized laboratories, is becoming more and more popular. The theoretical advantages of POCT are faster turn-around-times (TAT), more rapid medical decisions, avoidance of sample identification and sample transport problems and the need of only small specimen volumes. These advantages are frequently mentioned, but are not associated with a clear clinical benefit. The disadvantages of POCT such as incorrect handling and/or maintenance of the analyzers by nontrained clinical staff, inadequate or even absent calibrations and/or quality controls, lack of cost-effectiveness because of an increased number of analyzers and more expensive reagents, insufficient documentation and difficult comparability of the obtained POCT-results with routine laboratory results, are strongly evident. According to the authors' opinion the decision for the establishing of POCT has only to be made in a close co-operation between physicians and laboratorians in order to vouch for necessity and high quality of the analyses. Taking the local situation into consideration (24-h-central laboratory, etc.) the spectrum of parameters measured by means of POCT should be rigorously restricted to the vital functions. Such analytes should be: hemoglobin or hematocrit, activated whole blood clotting time, blood gases, sodium, potassium, ionized calcium, glucose, creatinine, ammonia and lactate.

  11. 7 CFR 75.43 - Laboratory testing.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Laboratory testing. 75.43 Section 75.43 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946 AND THE...

  12. Mars Science Laboratory Workstation Test Set

    NASA Technical Reports Server (NTRS)

    Henriquez, David A.; Canham, Timothy K.; Chang, Johnny T.; Villaume, Nathaniel

    2009-01-01

    The Mars Science Laboratory developed the Workstation TestSet (WSTS) is a computer program that enables flight software development on virtual MSL avionics. The WSTS is the non-real-time flight avionics simulator that is designed to be completely software-based and run on a workstation class Linux PC.

  13. 1. Exterior view of Components Test Laboratory (T27), looking southeast ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Exterior view of Components Test Laboratory (T-27), looking southeast from hill north of structure. The building wing in the right foreground houses Test Cell 8 (oxidizer) and the oxidizer storage pit or vault. Test Cell 10 is located in the center background, Test Cell 9 is at the far left, and the equipment room is in the immediate left foreground. The control room is in the center of the structure and abuts the aforementioned test cell and equipment room wings. This structure served as a facility for testing, handling, and storage of Titan II's hydrazine- and nitrogen teteroxide-based propellant system components for compatability determinations. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  14. Laboratory testing of alcohol safety interlock systems employing divided attention tests

    DOT National Transportation Integrated Search

    1975-12-01

    Author's abstract: Prototype Alcohol Safety Interlock Systems employing measurements of tracking ability, reaction time, and response accuracy to discern alcohol impairment were submitted to laboratory testing. These systems were modified versions of...

  15. Electronics systems test laboratory testing of shuttle communications systems

    NASA Technical Reports Server (NTRS)

    Stoker, C. J.; Bromley, L. K.

    1985-01-01

    Shuttle communications and tracking systems space to space and space to ground compatibility and performance evaluations are conducted in the NASA Johnson Space Center Electronics Systems Test Laboratory (ESTL). This evaluation is accomplished through systems verification/certification tests using orbiter communications hardware in conjunction with other shuttle communications and tracking external elements to evaluate end to end system compatibility and to verify/certify that overall system performance meets program requirements before manned flight usage. In this role, the ESTL serves as a multielement major ground test facility. The ESTL capability and program concept are discussed. The system test philosophy for the complex communications channels is described in terms of the major phases. Results of space to space and space to ground systems tests are presented. Several examples of the ESTL's unique capabilities to locate and help resolve potential problems are discussed in detail.

  16. Long-term pavement performance project laboratory materials testing and handling guide

    DOT National Transportation Integrated Search

    2007-09-01

    The Long Term Pavement Performance (LTPP) Laboratory Material Testing Guide was originally prepared for laboratory material handling and testing of material specimens and samples of asphalt materials, portland cement concrete, aggregates, and soils u...

  17. Impact of external haematology proficiency testing programme on quality of laboratories.

    PubMed

    Saxena, Renu; Katoch, S C; Srinivas, Upendra; Rao, Seema; Anand, Hema

    2007-11-01

    A reliable and reproducible report from a laboratory needs internal quality control within the laboratory and participation in external proficiency testing programmes (EPTP). This study conducted at the Department of Haematology, All India Institute of Medical Sciences (AIIMS), New Delhi, which has been conducting an EPTP since 1992, was undertaken to assess the efficacy of this programme in improving the performance of participating laboratories in reporting test samples sent for Hb, total leucocyte count (TLC), reticulocyte count and assessment of peripheral blood smear (PBS). The samples were prepared in our laboratory according to the International Standards Organization (ISO) guidelines. The performance of individual laboratories was assessed using robust Z score, which is an indicator of acceptability of the test result. An improvement in the overall percentage of laboratories with acceptable reports was seen during the study period. It has increased from 38,40,40 per cent in 1992 to 85, 90,94.7 per cent in 2006 for Hb, TLC, reticulocyte count, respectively. However, the results for peripheral smear assessment improved only marginally. The external haematology proficiency testing programme run by our department for Hb, TLC, reticulocyte count, and peripheral blood smear assessment, has helped in improving the reporting standards of these parameters in Indian laboratories.

  18. The Mars Science Laboratory Touchdown Test Facility

    NASA Technical Reports Server (NTRS)

    White, Christopher; Frankovich, John; Yates, Phillip; Wells Jr, George H.; Losey, Robert

    2009-01-01

    In the Touchdown Test Program for the Mars Science Laboratory (MSL) mission, a facility was developed to use a full-scale rover vehicle and an overhead winch system to replicate the Skycrane landing event.

  19. Mars Science Laboratory Spacecraft Assembled for Testing

    NASA Image and Video Library

    2008-11-19

    The major components of NASA Mars Science Laboratory spacecraft -- cruise stage atop the aeroshell, which has the descent stage and rover inside -- were connected together in October 2008 for several weeks of system testing.

  20. 24th geotechnical laboratory testing short course

    DOT National Transportation Integrated Search

    2008-02-01

    This is a 3-day workshop/short course to teach practicing professionals techniques and procedures for conducting high quality geotechnical laboratory tests. Transportation facility design and construction begins with an investigation of the type, ext...

  1. 9. Exterior view, Test Cell 7, Systems Integration Laboratory Building ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. Exterior view, Test Cell 7, Systems Integration Laboratory Building (T-28), looking southwest. The enclosure discussed in CO-88-B-8 is at the right. - Air Force Plant PJKS, Systems Integration Laboratory, Systems Integration Laboratory Building, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  2. Approaches to quality management and accreditation in a genetic testing laboratory

    PubMed Central

    Berwouts, Sarah; Morris, Michael A; Dequeker, Elisabeth

    2010-01-01

    Medical laboratories, and specifically genetic testing laboratories, provide vital medical services to different clients: clinicians requesting a test, patients from whom the sample was collected, public health and medical-legal instances, referral laboratories and authoritative bodies. All expect results that are accurate and obtained in an efficient and effective manner, within a suitable time frame and at acceptable cost. There are different ways of achieving the end results, but compliance with International Organization for Standardization (ISO) 15189, the international standard for the accreditation of medical laboratories, is becoming progressively accepted as the optimal approach to assuring quality in medical testing. We present recommendations and strategies designed to aid genetic testing laboratories with the implementation of a quality management system, including key aspects such as document control, external quality assessment, internal quality control, internal audit, management review, validation, as well as managing the human side of change. The focus is on pragmatic approaches to attain the levels of quality management and quality assurance required for accreditation according to ISO 15189, within the context of genetic testing. Attention is also given to implementing efficient and effective quality improvement. PMID:20720559

  3. Quality assurance practices in Europe: a survey of molecular genetic testing laboratories

    PubMed Central

    Berwouts, Sarah; Fanning, Katrina; Morris, Michael A; Barton, David E; Dequeker, Elisabeth

    2012-01-01

    In the 2000s, a number of initiatives were taken internationally to improve quality in genetic testing services. To contribute to and update the limited literature available related to this topic, we surveyed 910 human molecular genetic testing laboratories, of which 291 (32%) from 29 European countries responded. The majority of laboratories were in the public sector (81%), affiliated with a university hospital (60%). Only a minority of laboratories was accredited (23%), and 26% was certified. A total of 22% of laboratories did not participate in external quality assessment (EQA) and 28% did not use reference materials (RMs). The main motivations given for accreditation were to improve laboratory profile (85%) and national recognition (84%). Nearly all respondents (95%) would prefer working in an accredited laboratory. In accredited laboratories, participation in EQA (P<0.0001), use of RMs (P=0.0014) and availability of continuous education (CE) on medical/scientific subjects (P=0.023), specific tasks (P=0.0018), and quality assurance (P<0.0001) were significantly higher than in non-accredited laboratories. Non-accredited laboratories expect higher restriction of development of new techniques (P=0.023) and improvement of work satisfaction (P=0.0002) than accredited laboratories. By using a quality implementation score (QIS), we showed that accredited laboratories (average score 92) comply better than certified laboratories (average score 69, P<0.001), and certified laboratories better than other laboratories (average score 44, P<0.001), with regard to the implementation of quality indicators. We conclude that quality practices vary widely in European genetic testing laboratories. This leads to a potentially dangerous situation in which the quality of genetic testing is not consistently assured. PMID:22739339

  4. 6. Exterior view of Components Test Laboratory (T27), looking southwest. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. Exterior view of Components Test Laboratory (T-27), looking southwest. The building wing on the left houses Test Cell 9 (fuel), and that on the right houses the equipment room. The corrugated aluminum shed that is taller than the main building in the left foreground houses a citric acid air pollution control room (also known as scrubber room), the interior of which may be seen in CO-88-A-21. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  5. Hydrogen Field Test Standard: Laboratory and Field Performance

    PubMed Central

    Pope, Jodie G.; Wright, John D.

    2015-01-01

    The National Institute of Standards and Technology (NIST) developed a prototype field test standard (FTS) that incorporates three test methods that could be used by state weights and measures inspectors to periodically verify the accuracy of retail hydrogen dispensers, much as gasoline dispensers are tested today. The three field test methods are: 1) gravimetric, 2) Pressure, Volume, Temperature (PVT), and 3) master meter. The FTS was tested in NIST's Transient Flow Facility with helium gas and in the field at a hydrogen dispenser location. All three methods agree within 0.57 % and 1.53 % for all test drafts of helium gas in the laboratory setting and of hydrogen gas in the field, respectively. The time required to perform six test drafts is similar for all three methods, ranging from 6 h for the gravimetric and master meter methods to 8 h for the PVT method. The laboratory tests show that 1) it is critical to wait for thermal equilibrium to achieve density measurements in the FTS that meet the desired uncertainty requirements for the PVT and master meter methods; in general, we found a wait time of 20 minutes introduces errors < 0.1 % and < 0.04 % in the PVT and master meter methods, respectively and 2) buoyancy corrections are important for the lowest uncertainty gravimetric measurements. The field tests show that sensor drift can become a largest component of uncertainty that is not present in the laboratory setting. The scale was calibrated after it was set up at the field location. Checks of the calibration throughout testing showed drift of 0.031 %. Calibration of the master meter and the pressure sensors prior to travel to the field location and upon return showed significant drifts in their calibrations; 0.14 % and up to 1.7 %, respectively. This highlights the need for better sensor selection and/or more robust sensor testing prior to putting into field service. All three test methods are capable of being successfully performed in the field and give

  6. Workgroup for Hydraulic laboratory Testing and Verification of Hydroacoustic Instrumentation

    USGS Publications Warehouse

    Fulford, Janice M.; Armstrong, Brandy N.; Thibodeaux, Kirk G.

    2015-01-01

    An international workgroup was recently formed for hydraulic laboratory testing and verification of hydroacoustic instrumentation used for water velocity measurements. The activities of the workgroup have included one face to face meeting, conference calls and an inter-laboratory exchange of two acoustic meters among participating laboratories. Good agreement was found among four laboratories at higher tow speeds and poorer agreement at the lowest tow speed.

  7. Laboratory testing of gross solids removal devices.

    DOT National Transportation Integrated Search

    2005-05-01

    This report details the outcome of tests carried out at the Hydraulics Laboratory : of the University of California, Davis to assess the performance of three : alternative Gross Solids Removal Devices (GSRDs) developed by Caltrans to : remove litter ...

  8. LABORATORY TOXICITY TESTS FOR EVALUATING POTENTIAL EFFECTS OF ENDOCRINE-DISRUPTING COMPOUNDS

    EPA Science Inventory

    The scope of the Laboratory Testing Work Group was to evaluate methods for testing aquatic and terrestrial invertebrates in the laboratory. Specifically, discussions focused on the following objectives: 1) assess the extent to which consensus-based standard methods and other pub...

  9. 2000-hour cyclic endurance test of a laboratory model multipropellant resistojet

    NASA Technical Reports Server (NTRS)

    Morren, W. Earl; Sovey, James S.

    1987-01-01

    The technological readiness of a long-life multipropellant resistojet for space station auxiliary propulsion is demonstrated. A laboratory model resistojet made from grain-stabilized platinum served as a test bed to evaluate the design characteristics, fabrication methods, and operating strategies for an engineering model multipropellant resistojet developed under contract by the Rocketdyne Division of Rockwell International and Technion Incorporated. The laboratory model thruster was subjected to a 2000-hr, 2400-thermal-cycle endurance test using carbon dioxide propellant. Maximum thruster temperatures were approximately 1400 C. The post-test analyses of the laboratory model thruster included an investigation of component microstructures. Significant observations from the laboratory model thruster are discussed as they relate to the design of the engineering model thruster.

  10. The testing effect for mediator final test cues and related final test cues in online and laboratory experiments.

    PubMed

    Coppens, Leonora C; Verkoeijen, Peter P J L; Bouwmeester, Samantha; Rikers, Remy M J P

    2016-05-31

    The testing effect is the finding that information that is retrieved during learning is more often correctly retrieved on a final test than information that is restudied. According to the semantic mediator hypothesis the testing effect arises because retrieval practice of cue-target pairs (mother-child) activates semantically related mediators (father) more than restudying. Hence, the mediator-target (father-child) association should be stronger for retrieved than restudied pairs. Indeed, Carpenter (2011) found a larger testing effect when participants received mediators (father) than when they received target-related words (birth) as final test cues. The present study started as an attempt to test an alternative account of Carpenter's results. However, it turned into a series of conceptual (Experiment 1) and direct (Experiment 2 and 3) replications conducted with online samples. The results of these online replications were compared with those of similar existing laboratory experiments through small-scale meta-analyses. The results showed that (1) the magnitude of the raw mediator testing effect advantage is comparable for online and laboratory experiments, (2) in both online and laboratory experiments the magnitude of the raw mediator testing effect advantage is smaller than in Carpenter's original experiment, and (3) the testing effect for related cues varies considerably between online experiments. The variability in the testing effect for related cues in online experiments could point toward moderators of the related cue short-term testing effect. The raw mediator testing effect advantage is smaller than in Carpenter's original experiment.

  11. Advanced Materials Laboratory User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    Orndoff, Evelyne

    2012-01-01

    Test process, milestones and inputs are unknowns to first-time users of the Advanced Materials Laboratory. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  12. 19 CFR 151.54 - Testing by Customs laboratory.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 19 Customs Duties 2 2014-04-01 2014-04-01 false Testing by Customs laboratory. 151.54 Section 151.54 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Metal-Bearing Ores and...

  13. 19 CFR 151.54 - Testing by Customs laboratory.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 19 Customs Duties 2 2011-04-01 2011-04-01 false Testing by Customs laboratory. 151.54 Section 151.54 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Metal-Bearing Ores and...

  14. 19 CFR 151.54 - Testing by Customs laboratory.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 19 Customs Duties 2 2013-04-01 2013-04-01 false Testing by Customs laboratory. 151.54 Section 151.54 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Metal-Bearing Ores and...

  15. Capability of the Gas Analysis and Testing Laboratory at the NASA Johnson Space Center

    NASA Technical Reports Server (NTRS)

    Broerman, Craig; Jimenez, Javier; Sweterlitsch, Jeff

    2012-01-01

    The Gas Analysis and Testing Laboratory is an integral part of the testing performed at the NASA Johnson Space Center. The Gas Analysis and Testing Laboratory is a high performance laboratory providing real time analytical instruments to support manned and unmanned testing. The lab utilizes precision gas chromatographs, gas analyzers and spectrophotometers to support the technology development programs within the NASA community. The Gas Analysis and Testing Laboratory works with a wide variety of customers and provides engineering support for user-specified applications in compressed gas, chemical analysis, general and research laboratory.

  16. Capability of the Gas Analysis and Testing Laboratory at the NASA Johnson Space Center

    NASA Technical Reports Server (NTRS)

    Broerman, Craig; Jimenez, Javier; Sweterlitsch, Jeff

    2011-01-01

    The Gas Analysis and Testing Laboratory is an integral part of the testing performed at the NASA Johnson Space Center. The Gas Analysis and Testing Laboratory is a high performance laboratory providing real time analytical instruments to support manned and unmanned testing. The lab utilizes precision gas chromatographs, gas analyzers and spectrophotometers to support the technology development programs within the NASA community. The Gas Analysis and Testing Laboratory works with a wide variety of customers and provides engineering support for user-specified applications in compressed gas, chemical analysis, general and research laboratory

  17. Obtaining patient test results from clinical laboratories: a survey of state law for pharmacists.

    PubMed

    Witry, Matthew J; Doucette, William R

    2009-01-01

    To identify states with laws that restrict to whom clinical laboratories may release copies of laboratory test results and to describe how these laws may affect pharmacists' ability to obtain patient laboratory test results. Researchers examined state statutes and administrative codes for all 50 states and the District of Columbia at the University of Iowa Law Library between June and July 2007. Researchers also consulted with lawyers, state Clinical Laboratory Improvement Amendments officers, and law librarians. Laws relating to the study objective were analyzed. 34 jurisdictions do not restrict the release of laboratory test results, while 17 states have laws that restrict to whom clinical laboratories can send copies of test results. In these states, pharmacists will have to use alternative sources, such as physician offices, to obtain test results. Pharmacists must consider state law before requesting copies of laboratory test results from clinical laboratories. This may be an issue that state pharmacy associations can address to increase pharmacist access to important patient information.

  18. Corrections of clinical chemistry test results in a laboratory information system.

    PubMed

    Wang, Sihe; Ho, Virginia

    2004-08-01

    The recently released reports by the Institute of Medicine, To Err Is Human and Patient Safety, have received national attention because of their focus on the problem of medical errors. Although a small number of studies have reported on errors in general clinical laboratories, there are, to our knowledge, no reported studies that focus on errors in pediatric clinical laboratory testing. To characterize the errors that have caused corrections to have to be made in pediatric clinical chemistry results in the laboratory information system, Misys. To provide initial data on the errors detected in pediatric clinical chemistry laboratories in order to improve patient safety in pediatric health care. All clinical chemistry staff members were informed of the study and were requested to report in writing when a correction was made in the laboratory information system, Misys. Errors were detected either by the clinicians (the results did not fit the patients' clinical conditions) or by the laboratory technologists (the results were double-checked, and the worksheets were carefully examined twice a day). No incident that was discovered before or during the final validation was included. On each Monday of the study, we generated a report from Misys that listed all of the corrections made during the previous week. We then categorized the corrections according to the types and stages of the incidents that led to the corrections. A total of 187 incidents were detected during the 10-month study, representing a 0.26% error detection rate per requisition. The distribution of the detected incidents included 31 (17%) preanalytic incidents, 46 (25%) analytic incidents, and 110 (59%) postanalytic incidents. The errors related to noninterfaced tests accounted for 50% of the total incidents and for 37% of the affected tests and orderable panels, while the noninterfaced tests and panels accounted for 17% of the total test volume in our laboratory. This pilot study provided the rate and

  19. CAP/ACMG proficiency testing for biochemical genetics laboratories: a summary of performance.

    PubMed

    Oglesbee, Devin; Cowan, Tina M; Pasquali, Marzia; Wood, Timothy C; Weck, Karen E; Long, Thomas; Palomaki, Glenn E

    2018-01-01

    PurposeTesting for inborn errors of metabolism is performed by clinical laboratories worldwide, each utilizing laboratory-developed procedures. We sought to summarize performance in the College of American Pathologists' (CAP) proficiency testing (PT) program and identify opportunities for improving laboratory quality. When evaluating PT data, we focused on a subset of laboratories that have participated in at least one survey since 2010.MethodsAn analysis of laboratory performance (2004 to 2014) on the Biochemical Genetics PT Surveys, a program administered by CAP and the American College of Medical Genetics and Genomics. Analytical and interpretive performance was evaluated for four tests: amino acids, organic acids, acylcarnitines, and mucopolysaccharides.ResultsSince 2010, 150 laboratories have participated in at least one of four PT surveys. Analytic sensitivities ranged from 88.2 to 93.4%, while clinical sensitivities ranged from 82.4 to 91.0%. Performance was higher for US participants and for more recent challenges. Performance was lower for challenges with subtle findings or complex analytical patterns.ConclusionUS clinical biochemical genetics laboratory proficiency is satisfactory, with a minority of laboratories accounting for the majority of errors. Our findings underscore the complex nature of clinical biochemical genetics testing and highlight the necessity of continuous quality management.

  20. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Procedural Terminology published by the American Medical Association. (vii) Diagnostic tests performed by a... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  1. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Procedural Terminology published by the American Medical Association. (vii) Diagnostic tests performed by a... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  2. Access to laboratory testing: the impact of managed care in the Pacific Northwest.

    PubMed

    LaBeau, K M; Simon, M; Steindel, S J

    1999-01-01

    Patient access to health-care services has become an important issue owing to the growth of managed care organizations and the number of patients enrolled. To better understand the current issues related to access to laboratory testing, with a particular focus on the impact of managed care, we gathered information from a network of clinical laboratories in the Pacific Northwest. Two questionnaires were sent to the 257 Laboratory Medicine Sentinel Monitoring Network participants in November 1995 and March 1996 to investigate trends in the availability and utilization of laboratory testing services and changes in onsite testing menus. Although laboratories reported that managed care was a factor in their decisions about laboratory practices, testing decisions were more likely made for business reasons, based on medical practice changes and marketplace influences not associated with managed care.

  3. In-flight and laboratory vacuum-friction test results

    NASA Technical Reports Server (NTRS)

    Devine, E. J.; Evans, H. E.; Leasure, W. A.

    1973-01-01

    Coefficient of friction measurements were made for six unlubricated metal couples exposed to the space environment aboard the OV-1-13 spacecraft and exposed to laboratory vacuum. Materials studied included mutually soluble, partially soluble, and insoluble metal combinations. Two samples of each material couple were tested in space and in the laboratory using the disk and rider technique. Linear velocity was 0.10 cm/s (2.5 in/min) and rider normal load was 4.45 N (1 lb) for the gold versus silver couples and 8.90 N (2lb) for the other combinations. Results showed that friction data obtained in a clean ion-pumped laboratory vacuum of 10 to the minus 10 power materials with low mutual solubility can be correlated to operation in the vicinity of a typical scientific spacecraft that is exposed to an ambient pressure as low as 10 to the minus 12 power torr. The expected increase in coefficient of friction with solubility was shown. Material couples with high mutual solubility present the hazard of unpredictable drastic friction increase in orbit which may not be evident in laboratory testing at levels down to 10 to the minus 10 power torr. It was also shown that gross cold welding of unlubricated metals exposed to a satellite environment does not occur.

  4. Duplicate laboratory test reduction using a clinical decision support tool.

    PubMed

    Procop, Gary W; Yerian, Lisa M; Wyllie, Robert; Harrison, A Marc; Kottke-Marchant, Kandice

    2014-05-01

    Duplicate laboratory tests that are unwarranted increase unnecessary phlebotomy, which contributes to iatrogenic anemia, decreased patient satisfaction, and increased health care costs. We employed a clinical decision support tool (CDST) to block unnecessary duplicate test orders during the computerized physician order entry (CPOE) process. We assessed laboratory cost savings after 2 years and searched for untoward patient events associated with this intervention. This CDST blocked 11,790 unnecessary duplicate test orders in these 2 years, which resulted in a cost savings of $183,586. There were no untoward effects reported associated with this intervention. The movement to CPOE affords real-time interaction between the laboratory and the physician through CDSTs that signal duplicate orders. These interactions save health care dollars and should also increase patient satisfaction and well-being.

  5. Mars Science Laboratory Rover System Thermal Test

    NASA Technical Reports Server (NTRS)

    Novak, Keith S.; Kempenaar, Joshua E.; Liu, Yuanming; Bhandari, Pradeep; Dudik, Brenda A.

    2012-01-01

    On November 26, 2011, NASA launched a large (900 kg) rover as part of the Mars Science Laboratory (MSL) mission to Mars. The MSL rover is scheduled to land on Mars on August 5, 2012. Prior to launch, the Rover was successfully operated in simulated mission extreme environments during a 16-day long Rover System Thermal Test (STT). This paper describes the MSL Rover STT, test planning, test execution, test results, thermal model correlation and flight predictions. The rover was tested in the JPL 25-Foot Diameter Space Simulator Facility at the Jet Propulsion Laboratory (JPL). The Rover operated in simulated Cruise (vacuum) and Mars Surface environments (8 Torr nitrogen gas) with mission extreme hot and cold boundary conditions. A Xenon lamp solar simulator was used to impose simulated solar loads on the rover during a bounding hot case and during a simulated Mars diurnal test case. All thermal hardware was exercised and performed nominally. The Rover Heat Rejection System, a liquid-phase fluid loop used to transport heat in and out of the electronics boxes inside the rover chassis, performed better than predicted. Steady state and transient data were collected to allow correlation of analytical thermal models. These thermal models were subsequently used to predict rover thermal performance for the MSL Gale Crater landing site. Models predict that critical hardware temperatures will be maintained within allowable flight limits over the entire 669 Sol surface mission.

  6. Trends in Testing for Mycobacterium tuberculosis Complex From US Public Health Laboratories, 2009-2013.

    PubMed

    Tyrrell, Frances; Stafford, Cortney; Yakrus, Mitchell; Youngblood, Monica; Hill, Andrew; Johnston, Stephanie

    We investigated data from US public health laboratories funded through the Centers for Disease Control and Prevention's Tuberculosis Elimination and Laboratory Cooperative Agreement to document trends and challenges in meeting national objectives in tuberculosis (TB) laboratory diagnoses. We examined data on workload and turnaround time from public health laboratories' progress reports during 2009-2013. We reviewed methodologies, laboratory roles, and progress toward rapid detection of Mycobacterium tuberculosis complex through nucleic acid amplification (NAA) testing. We compared selected data with TB surveillance reports to estimate public health laboratories' contribution to national diagnostic services. During the study period, culture and drug susceptibility tests decreased, but NAA testing increased. Public health laboratories achieved turnaround time benchmarks for drug susceptibility tests at lower levels than for acid-fast bacilli smear and identification from culture. NAA positivity in laboratories among surveillance-reported culture-positive TB cases increased from 26.6% (2355 of 8876) in 2009 to 40.0% (2948 of 7358) in 2013. Public health laboratories provided an estimated 50.9% (4285 of 8413 in 2010) to 57.2% (4210 of 7358 in 2013) of culture testing and 88.3% (6822 of 7727 in 2011) to 94.4% (6845 of 7250 in 2012) of drug susceptibility tests for all US TB cases. Public health laboratories contribute substantially to TB diagnoses in the United States. Although testing volumes mostly decreased, the increase in NAA testing indicates continued progress in rapid M tuberculosis complex detection.

  7. Laboratory test for ice adhesion strength using commercial instrumentation.

    PubMed

    Wang, Chenyu; Zhang, Wei; Siva, Adarsh; Tiea, Daniel; Wynne, Kenneth J

    2014-01-21

    A laboratory test method for evaluating ice adhesion has been developed employing a commercially available instrument normally used for dynamic mechanical analysis (TA RSA-III). This is the first laboratory ice adhesion test that does not require a custom-built apparatus. The upper grip range of ∼10 mm is an enabling feature that is essential for the test. The method involves removal of an ice cylinder from a polymer coating with a probe and the determination of peak removal force (Ps). To validate the test method, the strength of ice adhesion was determined for a prototypical glassy polymer, poly(methyl methacrylate). The distance of the probe from the PMMA surface has been identified as a critical variable for Ps. The new test provides a readily available platform for investigating fundamental surface characteristics affecting ice adhesion. In addition to the ice release test, PMMA coatings were characterized using DSC, DCA, and TM-AFM.

  8. Pilot instrumentation of a Superpave test section at the Kansas Accelerated Testing laboratory

    DOT National Transportation Integrated Search

    2003-04-01

    Two Superpave test sections were constructed at the Kansas Accelerated Testing Laboratory (K-ATL) with 12.5 mm (2 in) nominal maximum size Superpave mixture (SM-2A) with varying percentages (15 and 30 percent) of river sand. A 150 kN (34 kip) tandem ...

  9. Performance testing of radiobioassay laboratories: In vivo measurements, Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacLellan, J.A.; Traub, R.J.; Olsen, P.C.

    1990-04-01

    A study of two rounds of in vivo laboratory performance testing was undertaken by Pacific Northwest Laboratory (PNL) to determine the appropriateness of the in vivo performance criteria of draft American National Standards Institute (ANSI) standard ANSI N13.3, Performance Criteria for Bioassay.'' The draft standard provides guidance to in vivo counting facilities regarding the sensitivity, precision, and accuracy of measurements for certain categories of commonly assayed radionuclides and critical regions of the body. This report concludes the testing program by presenting the results of the Round Two testing. Testing involved two types of measurements: chest counting for radionuclide detection inmore » the lung, and whole body counting for detection of uniformly distributed material. Each type of measurement was further divided into radionuclide categories as defined in the draft standard. The appropriateness of the draft standard criteria by measuring a laboratory's ability to attain them were judged by the results of both round One and Round Two testing. The testing determined that performance criteria are set at attainable levels, and the majority of in vivo monitoring facilities passed the criteria when complete results were submitted. 18 refs., 18 figs., 15 tabs.« less

  10. Analysis and Test Support for Phillips Laboratory Precision Structures

    DTIC Science & Technology

    1998-11-01

    Air Force Research Laboratory ( AFRL ), Phillips Research Site . Task objectives centered...around analysis and structural dynamic test support on experiments within the Space Vehicles Directorate at Kirtland Air Force Base. These efforts help...support for Phillips Laboratory Precision Structures." Mr. James Goodding of CSA Engineering was the principal investigator for this task. Mr.

  11. Educational ultrasound nondestructive testing laboratory.

    PubMed

    Genis, Vladimir; Zagorski, Michael

    2008-09-01

    The ultrasound nondestructive evaluation (NDE) of materials course was developed for applied engineering technology students at Drexel University's Goodwin College of Professional Studies. This three-credit, hands-on laboratory course consists of two parts: the first part with an emphasis on the foundations of NDE, and the second part during which ultrasound NDE techniques are utilized in the evaluation of parts and materials. NDE applications are presented and applied through real-life problems, including calibration and use of the latest ultrasonic testing instrumentation. The students learn engineering and physical principles of measurements of sound velocity in different materials, attenuation coefficients, material thickness, and location and dimensions of discontinuities in various materials, such as holes, cracks, and flaws. The work in the laboratory enhances the fundamentals taught during classroom sessions. This course will ultimately result in improvements in the educational process ["The greater expectations," national panel report, http://www.greaterexpectations.org (last viewed February, 2008); R. M. Felder and R. Brent "The intellectual development of Science and Engineering Students. Part 2: Teaching to promote growth," J. Eng. Educ. 93, 279-291 (2004)] since industry is becoming increasingly reliant on the effective application of NDE technology and the demand on NDE specialists is increasing. NDE curriculum was designed to fulfill levels I and II NDE in theory and training requirements, according to American Society for Nondestructive Testing, OH, Recommended Practice No. SNT-TC-1A (2006).

  12. The quality of veterinary in-clinic and reference laboratory biochemical testing.

    PubMed

    Rishniw, Mark; Pion, Paul D; Maher, Tammy

    2012-03-01

    Although evaluation of biochemical analytes in blood is common in veterinary practice, studies assessing the global quality of veterinary in-clinic and reference laboratory testing have not been reported. The aim of this study was to assess the quality of biochemical testing in veterinary laboratories using results obtained from analyses of 3 levels of assayed quality control materials over 5 days. Quality was assessed by comparison of calculated total error with quality requirements, determination of sigma metrics, use of a quality goal index to determine factors contributing to poor performance, and agreement between in-clinic and reference laboratory mean results. The suitability of in-clinic and reference laboratory instruments for statistical quality control was determined using adaptations from the computerized program, EZRules3. Reference laboratories were able to achieve desirable quality requirements more frequently than in-clinic laboratories. Across all 3 materials, > 50% of in-clinic analyzers achieved a sigma metric ≥ 6.0 for measurement of 2 analytes, whereas > 50% of reference laboratory analyzers achieved a sigma metric ≥ 6.0 for measurement of 6 analytes. Expanded uncertainty of measurement and ± total allowable error resulted in the highest mean percentages of analytes demonstrating agreement between in-clinic and reference laboratories. Owing to marked variation in bias and coefficient of variation between analyzers of the same and different types, the percentages of analytes suitable for statistical quality control varied widely. These findings reflect the current state-of-the-art with regard to in-clinic and reference laboratory analyzer performance and provide a baseline for future evaluations of the quality of veterinary laboratory testing. © 2012 American Society for Veterinary Clinical Pathology.

  13. Text Messaging Improves Participation in Laboratory Testing in Adolescent Liver Transplant Patients.

    PubMed

    McKenzie, Rebecca B; Berquist, William E; Foley, Megan A; Park, K T; Windsheimer, Jered E; Litt, Iris F

    In solid organ transplant patients, non-participation in all aspects of the medical regimen is a prevalent problem associated with adverse consequences particularly in the adolescent and young adult (AYA) age group. This study is the first to evaluate the feasibility, utility and impact of a text messaging (TM) intervention to improve participation in laboratory testing in adolescent liver transplant patients. AYA patients, aged 12 to 21 years, were recruited for a prospective pilot trial evaluating a TM intervention delivered over a 1-year period. The intervention involved automated TM reminders with feedback administered according to a prescribed laboratory testing frequency. Participation rate in laboratory testing after the intervention was compared to the year prior. Patient responses and feedback by text and survey were used to assess feasibility, acceptability and use of the intervention. Forty-two patients were recruited and 33 patients remained enrolled for the study duration. Recipients of the TM intervention demonstrated a significant improvement in participation rate in laboratory testing from 58% to 78% (P<.001). This rate was also significantly higher than in non-intervention controls (P=.003). There was a high acceptability, response rate and a significant correlation with reported versus actual completion of laboratory tests by TM. TM reminders significantly improved participation in laboratory testing in AYA liver transplant patients. The intervention demonstrated feasibility, acceptability, and use with a high proportion of patients who engaged in and perceived a benefit from using this technology.

  14. Laboratory testing in primary care: A systematic review of health IT impacts.

    PubMed

    Maillet, Éric; Paré, Guy; Currie, Leanne M; Raymond, Louis; Ortiz de Guinea, Ana; Trudel, Marie-Claude; Marsan, Josianne

    2018-08-01

    Laboratory testing in primary care is a fundamental process that supports patient management and care. Any breakdown in the process may alter clinical information gathering and decision-making activities and can lead to medical errors and potential adverse outcomes for patients. Various information technologies are being used in primary care with the goal to support the process, maximize patient benefits and reduce medical errors. However, the overall impact of health information technologies on laboratory testing processes has not been evaluated. To synthesize the positive and negative impacts resulting from the use of health information technology in each phase of the laboratory 'total testing process' in primary care. We conducted a systematic review. Databases including Medline, PubMed, CINAHL, Web of Science and Google Scholar were searched. Studies eligible for inclusion reported empirical data on: 1) the use of a specific IT system, 2) the impacts of the systems to support the laboratory testing process, and were conducted in 3) primary care settings (including ambulatory care and primary care offices). Our final sample consisted of 22 empirical studies which were mapped to a framework that outlines the phases of the laboratory total testing process, focusing on phases where medical errors may occur. Health information technology systems support several phases of the laboratory testing process, from ordering the test to following-up with patients. This is a growing field of research with most studies focusing on the use of information technology during the final phases of the laboratory total testing process. The findings were largely positive. Positive impacts included easier access to test results by primary care providers, reduced turnaround times, and increased prescribed tests based on best practice guidelines. Negative impacts were reported in several studies: paper-based processes employed in parallel to the electronic process increased the potential

  15. Remotely accessible laboratory for MEMS testing

    NASA Astrophysics Data System (ADS)

    Sivakumar, Ganapathy; Mulsow, Matthew; Melinger, Aaron; Lacouture, Shelby; Dallas, Tim E.

    2010-02-01

    We report on the construction of a remotely accessible and interactive laboratory for testing microdevices (aka: MicroElectroMechancial Systems - MEMS). Enabling expanded utilization of microdevices for research, commercial, and educational purposes is very important for driving the creation of future MEMS devices and applications. Unfortunately, the relatively high costs associated with MEMS devices and testing infrastructure makes widespread access to the world of MEMS difficult. The creation of a virtual lab to control and actuate MEMS devices over the internet helps spread knowledge to a larger audience. A host laboratory has been established that contains a digital microscope, microdevices, controllers, and computers that can be logged into through the internet. The overall layout of the tele-operated MEMS laboratory system can be divided into two major parts: the server side and the client side. The server-side is present at Texas Tech University, and hosts a server machine that runs the Linux operating system and is used for interfacing the MEMS lab with the outside world via internet. The controls from the clients are transferred to the lab side through the server interface. The server interacts with the electronics required to drive the MEMS devices using a range of National Instruments hardware and LabView Virtual Instruments. An optical microscope (100 ×) with a CCD video camera is used to capture images of the operating MEMS. The server broadcasts the live video stream over the internet to the clients through the website. When the button is pressed on the website, the MEMS device responds and the video stream shows the movement in close to real time.

  16. 40 CFR Appendix II to Part 1054 - Duty Cycles for Laboratory Testing

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Duty Cycles for Laboratory Testing II.... 1054, App. II Appendix II to Part 1054—Duty Cycles for Laboratory Testing (a) Test handheld engines with the following steady-state duty cycle: G3 mode No. Engine speed a Torque(percent) b Weighting...

  17. 42 CFR 493.20 - Laboratories performing tests of moderate complexity.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Laboratories performing tests of moderate complexity. 493.20 Section 493.20 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS General...

  18. 42 CFR 493.20 - Laboratories performing tests of moderate complexity.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Laboratories performing tests of moderate complexity. 493.20 Section 493.20 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS General...

  19. The laboratory test utilization management toolbox

    PubMed Central

    Baird, Geoffrey

    2014-01-01

    Efficiently managing laboratory test utilization requires both ensuring adequate utilization of needed tests in some patients and discouraging superfluous tests in other patients. After the difficult clinical decision is made to define the patients that do and do not need a test, a wealth of interventions are available to the clinician and laboratorian to help guide appropriate utilization. These interventions are collectively referred to here as the utilization management toolbox. Experience has shown that some tools in the toolbox are weak and other are strong, and that tools are most effective when many are used simultaneously. While the outcomes of utilization management studies are not always as concrete as may be desired, what data is available in the literature indicate that strong utilization management interventions are safe and effective measures to improve patient health and reduce waste in an era of increasing financial pressure. PMID:24969916

  20. A 2000-hour cyclic endurance test of a laboratory model multipropellant resistojet

    NASA Technical Reports Server (NTRS)

    Morren, W. Earl; Sovey, James S.

    1987-01-01

    The technological readiness of a long-life multipropellant resistojet for space station auxiliary propulsion is demonstrated. A laboratory model resistojet made from grain-stabilized platinum served as a test bed to evaluate the design characteristics, fabrication methods, and operating strategies for an engineering model multipropellant resistojet developed under contract by the Rocketdyne Division of Rockwell International and Technion Incorporated. The laboratory model thruster was subjected to a 2000-hr, 2400-thermal-cycle endurance test using carbon dioxide propellant. Maximum thruster temperatures were approximately 1400 C. The post-test analyses of the laboratory model thruster included an investigation of component microstructures. Significant observations from the laboratory model thruster are discussed as they relate to the design of the engineering model thruster.

  1. Effectiveness of a computerized alert system based on re-testing intervals for limiting the inappropriateness of laboratory test requests.

    PubMed

    Lippi, Giuseppe; Brambilla, Marco; Bonelli, Patrizia; Aloe, Rosalia; Balestrino, Antonio; Nardelli, Anna; Ceda, Gian Paolo; Fabi, Massimo

    2015-11-01

    There is consolidated evidence that the burden of inappropriate laboratory test requests is very high, up to 70%. We describe here the function of a computerized alert system linked to the order entry, designed to limit the number of potentially inappropriate laboratory test requests. A computerized alert system based on re-testing intervals and entailing the generation of pop-up alerts when preset criteria of appropriateness for 15 laboratory tests were violated was implemented in two clinical wards of the University Hospital of Parma. The effectiveness of the system for limiting potentially inappropriate tests was monitored for 6months. Overall, 765/3539 (22%) test requests violated the preset criteria of appropriateness and generated the appearance of electronic alert. After alert appearance, 591 requests were annulled (17% of total tests requested and 77% of tests alerted, respectively). The total number of test requests violating the preset criteria of inappropriateness constantly decreased over time (26% in the first three months of implementation versus 17% in the following period; p<0.001). The total financial saving of test withdrawn was 3387 Euros (12.8% of the total test cost) throughout the study period. The results of this study suggest that a computerized alert system may be effective to limit the inappropriateness of laboratory test requests, generating significant economic saving and educating physicians to a more efficient use of laboratory resources. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  2. LabRS: A Rosetta stone for retrospective standardization of clinical laboratory test results.

    PubMed

    Hauser, Ronald George; Quine, Douglas B; Ryder, Alex

    2018-02-01

    Clinical laboratories in the United States do not have an explicit result standard to report the 7 billion laboratory tests results they produce each year. The absence of standardized test results creates inefficiencies and ambiguities for secondary data users. We developed and tested a tool to standardize the results of laboratory tests in a large, multicenter clinical data warehouse. Laboratory records, each of which consisted of a laboratory result and a test identifier, from 27 diverse facilities were captured from 2000 through 2015. Each record underwent a standardization process to convert the original result into a format amenable to secondary data analysis. The standardization process included the correction of typos, normalization of categorical results, separation of inequalities from numbers, and conversion of numbers represented by words (eg, "million") to numerals. Quality control included expert review. We obtained 1.266 × 109 laboratory records and standardized 1.252 × 109 records (98.9%). Of the unique unstandardized records (78.887 × 103), most appeared <5 times (96%, eg, typos), did not have a test identifier (47%), or belonged to an esoteric test with <100 results (2%). Overall, these 3 reasons accounted for nearly all unstandardized results (98%). Current results suggest that the tool is both scalable and generalizable among diverse clinical laboratories. Based on observed trends, the tool will require ongoing maintenance to stay current with new tests and result formats. Future work to develop and implement an explicit standard for test results would reduce the need to retrospectively standardize test results. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  3. System reliability of randomly vibrating structures: Computational modeling and laboratory testing

    NASA Astrophysics Data System (ADS)

    Sundar, V. S.; Ammanagi, S.; Manohar, C. S.

    2015-09-01

    The problem of determination of system reliability of randomly vibrating structures arises in many application areas of engineering. We discuss in this paper approaches based on Monte Carlo simulations and laboratory testing to tackle problems of time variant system reliability estimation. The strategy we adopt is based on the application of Girsanov's transformation to the governing stochastic differential equations which enables estimation of probability of failure with significantly reduced number of samples than what is needed in a direct simulation study. Notably, we show that the ideas from Girsanov's transformation based Monte Carlo simulations can be extended to conduct laboratory testing to assess system reliability of engineering structures with reduced number of samples and hence with reduced testing times. Illustrative examples include computational studies on a 10-degree of freedom nonlinear system model and laboratory/computational investigations on road load response of an automotive system tested on a four-post test rig.

  4. College of American Pathologists' laboratory standards for next-generation sequencing clinical tests.

    PubMed

    Aziz, Nazneen; Zhao, Qin; Bry, Lynn; Driscoll, Denise K; Funke, Birgit; Gibson, Jane S; Grody, Wayne W; Hegde, Madhuri R; Hoeltge, Gerald A; Leonard, Debra G B; Merker, Jason D; Nagarajan, Rakesh; Palicki, Linda A; Robetorye, Ryan S; Schrijver, Iris; Weck, Karen E; Voelkerding, Karl V

    2015-04-01

    The higher throughput and lower per-base cost of next-generation sequencing (NGS) as compared to Sanger sequencing has led to its rapid adoption in clinical testing. The number of laboratories offering NGS-based tests has also grown considerably in the past few years, despite the fact that specific Clinical Laboratory Improvement Amendments of 1988/College of American Pathologists (CAP) laboratory standards had not yet been developed to regulate this technology. To develop a checklist for clinical testing using NGS technology that sets standards for the analytic wet bench process and for bioinformatics or "dry bench" analyses. As NGS-based clinical tests are new to diagnostic testing and are of much greater complexity than traditional Sanger sequencing-based tests, there is an urgent need to develop new regulatory standards for laboratories offering these tests. To develop the necessary regulatory framework for NGS and to facilitate appropriate adoption of this technology for clinical testing, CAP formed a committee in 2011, the NGS Work Group, to deliberate upon the contents to be included in the checklist. Results . -A total of 18 laboratory accreditation checklist requirements for the analytic wet bench process and bioinformatics analysis processes have been included within CAP's molecular pathology checklist (MOL). This report describes the important issues considered by the CAP committee during the development of the new checklist requirements, which address documentation, validation, quality assurance, confirmatory testing, exception logs, monitoring of upgrades, variant interpretation and reporting, incidental findings, data storage, version traceability, and data transfer confidentiality.

  5. Laboratory Tests

    MedlinePlus

    ... PI CONNECT Research Network USIDNET Patient Registry IDF Survey Research IDF Surveys National Health Insurance Surveys Clinical Trials ... and Fellows Research USIDNET IDF Research Fund IDF Survey Research IDF Surveys Contact Us Search form Search Laboratory ...

  6. 49 CFR 40.89 - What is validity testing, and are laboratories required to conduct it?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.89 What is validity testing, and are laboratories required to conduct it? (a) Specimen validity testing is... 49 Transportation 1 2013-10-01 2013-10-01 false What is validity testing, and are laboratories...

  7. 49 CFR 40.89 - What is validity testing, and are laboratories required to conduct it?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.89 What is validity testing, and are laboratories required to conduct it? (a) Specimen validity testing is... 49 Transportation 1 2011-10-01 2011-10-01 false What is validity testing, and are laboratories...

  8. 49 CFR 40.89 - What is validity testing, and are laboratories required to conduct it?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.89 What is validity testing, and are laboratories required to conduct it? (a) Specimen validity testing is... 49 Transportation 1 2010-10-01 2010-10-01 false What is validity testing, and are laboratories...

  9. 49 CFR 40.89 - What is validity testing, and are laboratories required to conduct it?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.89 What is validity testing, and are laboratories required to conduct it? (a) Specimen validity testing is... 49 Transportation 1 2012-10-01 2012-10-01 false What is validity testing, and are laboratories...

  10. 49 CFR 40.89 - What is validity testing, and are laboratories required to conduct it?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.89 What is validity testing, and are laboratories required to conduct it? (a) Specimen validity testing is... 49 Transportation 1 2014-10-01 2014-10-01 false What is validity testing, and are laboratories...

  11. 42 CFR 493.1453 - Condition: Laboratories performing high complexity testing; clinical consultant.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... testing; clinical consultant. 493.1453 Section 493.1453 Public Health CENTERS FOR MEDICARE & MEDICAID... Condition: Laboratories performing high complexity testing; clinical consultant. The laboratory must have a clinical consultant who meets the requirements of § 493.1455 of this subpart and provides clinical...

  12. 42 CFR 493.1415 - Condition: Laboratories performing moderate complexity testing; clinical consultant.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... complexity testing; clinical consultant. 493.1415 Section 493.1415 Public Health CENTERS FOR MEDICARE... § 493.1415 Condition: Laboratories performing moderate complexity testing; clinical consultant. The laboratory must have a clinical consultant who meets the qualification requirements of § 493.1417 of this...

  13. A comparison of relative toxicity rankings by some small-scale laboratory tests

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Cumming, H. J.

    1977-01-01

    Small-scale laboratory tests for fire toxicity, suitable for use in the average laboratory hood, are needed for screening and ranking materials on the basis of relative toxicity. The performance of wool, cotton, and aromatic polyamide under several test procedures is presented.

  14. Flight Testing the Landing Radar for Mars Science Laboratory

    NASA Image and Video Library

    2011-06-21

    A NASA Dryden Flight Research Center F/A-18 852 aircraft performs a roll during June 2011 flight tests of a Mars landing radar. A test model of the landing radar for NASA Mars Science Laboratory mission is inside a pod under the aircraft left wing.

  15. The Role of Laboratory Tests in Crohn’s Disease

    PubMed Central

    Cappello, Maria; Morreale, Gaetano Cristian

    2016-01-01

    In the past, laboratory tests were considered of limited value in Crohn’s disease (CD). In the era of biologics, laboratory tests have become essential to evaluate the inflammatory burden of the disease (C-reactive protein, fecal calprotectin) since symptoms-based scores are subjective, to predict the response to pharmacological options and the risk of relapse, to discriminate CD from ulcerative colitis, to select candidates to anti-tumor necrosis factors [screening tests looking for hepatitis B virus and hepatitis C virus status and latent tuberculosis], to assess the risk of adverse events (testing for thiopurine metabolites and thiopurine-methyltransferase activity), and to personalize and optimize therapy (therapeutic drug monitoring). Pharmacogenetics, though presently confined to the assessment of thiopurineme methyltransferase polymorphisms and hematological toxicity associated with thiopurine treatment, is a promising field that will contribute to a better understanding of the molecular mechanisms of the variability in response to the drugs used in CD with the attempt to expand personalized care and precision medicine strategies. PMID:27656094

  16. 10 CFR 707.12 - Specimen collection, handling and laboratory analysis for drug testing.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... drug testing. 707.12 Section 707.12 Energy DEPARTMENT OF ENERGY WORKPLACE SUBSTANCE ABUSE PROGRAMS AT DOE SITES Procedures § 707.12 Specimen collection, handling and laboratory analysis for drug testing... collection to final disposition of specimens, and testing laboratories shall use appropriate cutoff levels in...

  17. 10 CFR 707.12 - Specimen collection, handling and laboratory analysis for drug testing.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... drug testing. 707.12 Section 707.12 Energy DEPARTMENT OF ENERGY WORKPLACE SUBSTANCE ABUSE PROGRAMS AT DOE SITES Procedures § 707.12 Specimen collection, handling and laboratory analysis for drug testing... collection to final disposition of specimens, and testing laboratories shall use appropriate cutoff levels in...

  18. 10 CFR 707.12 - Specimen collection, handling and laboratory analysis for drug testing.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... drug testing. 707.12 Section 707.12 Energy DEPARTMENT OF ENERGY WORKPLACE SUBSTANCE ABUSE PROGRAMS AT DOE SITES Procedures § 707.12 Specimen collection, handling and laboratory analysis for drug testing... collection to final disposition of specimens, and testing laboratories shall use appropriate cutoff levels in...

  19. 10 CFR 707.12 - Specimen collection, handling and laboratory analysis for drug testing.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... drug testing. 707.12 Section 707.12 Energy DEPARTMENT OF ENERGY WORKPLACE SUBSTANCE ABUSE PROGRAMS AT DOE SITES Procedures § 707.12 Specimen collection, handling and laboratory analysis for drug testing... collection to final disposition of specimens, and testing laboratories shall use appropriate cutoff levels in...

  20. 10 CFR 707.12 - Specimen collection, handling and laboratory analysis for drug testing.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... drug testing. 707.12 Section 707.12 Energy DEPARTMENT OF ENERGY WORKPLACE SUBSTANCE ABUSE PROGRAMS AT DOE SITES Procedures § 707.12 Specimen collection, handling and laboratory analysis for drug testing... collection to final disposition of specimens, and testing laboratories shall use appropriate cutoff levels in...

  1. 40 CFR 270.63 - Permits for land treatment demonstrations using field test or laboratory analyses.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... demonstrations using field test or laboratory analyses. 270.63 Section 270.63 Protection of Environment... using field test or laboratory analyses. (a) For the purpose of allowing an owner or operator to meet... the field test or laboratory analyses, or as a two-phase facility permit covering the field tests, or...

  2. 40 CFR 270.63 - Permits for land treatment demonstrations using field test or laboratory analyses.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... demonstrations using field test or laboratory analyses. 270.63 Section 270.63 Protection of Environment... using field test or laboratory analyses. (a) For the purpose of allowing an owner or operator to meet... the field test or laboratory analyses, or as a two-phase facility permit covering the field tests, or...

  3. 40 CFR 270.63 - Permits for land treatment demonstrations using field test or laboratory analyses.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... demonstrations using field test or laboratory analyses. 270.63 Section 270.63 Protection of Environment... using field test or laboratory analyses. (a) For the purpose of allowing an owner or operator to meet... the field test or laboratory analyses, or as a two-phase facility permit covering the field tests, or...

  4. 40 CFR 270.63 - Permits for land treatment demonstrations using field test or laboratory analyses.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... demonstrations using field test or laboratory analyses. 270.63 Section 270.63 Protection of Environment... using field test or laboratory analyses. (a) For the purpose of allowing an owner or operator to meet... the field test or laboratory analyses, or as a two-phase facility permit covering the field tests, or...

  5. 40 CFR 270.63 - Permits for land treatment demonstrations using field test or laboratory analyses.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... demonstrations using field test or laboratory analyses. 270.63 Section 270.63 Protection of Environment... using field test or laboratory analyses. (a) For the purpose of allowing an owner or operator to meet... the field test or laboratory analyses, or as a two-phase facility permit covering the field tests, or...

  6. 19 CFR 151.73 - Importer's request for commercial laboratory test.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Hair § 151.73 Importer's request for commercial laboratory test. (a) Conditions for commercial test. If... request that a commercial test be made to determine the percentage clean yield of the wool or hair. (b... the wool or hair in dispute to be selected and tested by a commercial method approved by the...

  7. 19 CFR 151.73 - Importer's request for commercial laboratory test.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Hair § 151.73 Importer's request for commercial laboratory test. (a) Conditions for commercial test. If... request that a commercial test be made to determine the percentage clean yield of the wool or hair. (b... the wool or hair in dispute to be selected and tested by a commercial method approved by the...

  8. 19 CFR 151.73 - Importer's request for commercial laboratory test.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Hair § 151.73 Importer's request for commercial laboratory test. (a) Conditions for commercial test. If... request that a commercial test be made to determine the percentage clean yield of the wool or hair. (b... the wool or hair in dispute to be selected and tested by a commercial method approved by the...

  9. 19 CFR 151.73 - Importer's request for commercial laboratory test.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Hair § 151.73 Importer's request for commercial laboratory test. (a) Conditions for commercial test. If... request that a commercial test be made to determine the percentage clean yield of the wool or hair. (b... the wool or hair in dispute to be selected and tested by a commercial method approved by the...

  10. 19 CFR 151.73 - Importer's request for commercial laboratory test.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Hair § 151.73 Importer's request for commercial laboratory test. (a) Conditions for commercial test. If... request that a commercial test be made to determine the percentage clean yield of the wool or hair. (b... the wool or hair in dispute to be selected and tested by a commercial method approved by the...

  11. Methodology in diagnostic laboratory test research in clinical chemistry and clinical chemistry and laboratory medicine.

    PubMed

    Lumbreras-Lacarra, Blanca; Ramos-Rincón, José Manuel; Hernández-Aguado, Ildefonso

    2004-03-01

    The application of epidemiologic principles to clinical diagnosis has been less developed than in other clinical areas. Knowledge of the main flaws affecting diagnostic laboratory test research is the first step for improving its quality. We assessed the methodologic aspects of articles on laboratory tests. We included articles that estimated indexes of diagnostic accuracy (sensitivity and specificity) and were published in Clinical Chemistry or Clinical Chemistry and Laboratory Medicine in 1996, 2001, and 2002. Clinical Chemistry has paid special attention to this field of research since 1996 by publishing recommendations, checklists, and reviews. Articles were identified through electronic searches in Medline. The strategy combined the Mesh term "sensitivity and specificity" (exploded) with the text words "specificity", "false negative", and "accuracy". We examined adherence to seven methodologic criteria used in the study by Reid et al. (JAMA1995;274:645-51) of papers published in general medical journals. Three observers evaluated each article independently. Seventy-nine articles fulfilled the inclusion criteria. The percentage of studies that satisfied each criterion improved from 1996 to 2002. Substantial improvement was observed in reporting of the statistical uncertainty of indices of diagnostic accuracy, in criteria based on clinical information from the study population (spectrum composition), and in avoidance of workup bias. Analytical reproducibility was reported frequently (68%), whereas information about indeterminate results was rarely provided. The mean number of methodologic criteria satisfied showed a statistically significant increase over the 3 years in Clinical Chemistry but not in Clinical Chemistry and Laboratory Medicine. The methodologic quality of the articles on diagnostic test research published in Clinical Chemistry and Clinical Chemistry and Laboratory Medicine is comparable to the quality observed in the best general medical journals

  12. Safety in the Chemical Laboratory: Tested Disposal Methods for Chemical Wastes from Academic Laboratories.

    ERIC Educational Resources Information Center

    Armour, M. A.; And Others

    1985-01-01

    Describes procedures for disposing of dichromate cleaning solution, picric acid, organic azides, oxalic acid, chemical spills, and hydroperoxides in ethers and alkenes. These methods have been tested under laboratory conditions and are specific for individual chemicals rather than for groups of chemicals. (JN)

  13. Space Electric Research Test in the Electric Propulsion Laboratory

    NASA Image and Video Library

    1964-06-21

    Technicians prepare the Space Electric Research Test (SERT-I) payload for a test in Tank Number 5 of the Electric Propulsion Laboratory at the National Aeronautics and Space Administration (NASA) Lewis Research Center. Lewis researchers had been studying different methods of electric rocket propulsion since the mid-1950s. Harold Kaufman created the first successful engine, the electron bombardment ion engine, in the early 1960s. These electric engines created and accelerated small particles of propellant material to high exhaust velocities. Electric engines have a very small amount of thrust, but once lofted into orbit by workhorse chemical rockets, they are capable of small, continuous thrust for periods up to several years. The electron bombardment thruster operated at a 90-percent efficiency during testing in the Electric Propulsion Laboratory. The package was rapidly rotated in a vacuum to simulate its behavior in space. The SERT-I mission, launched from Wallops Island, Virginia, was the first flight test of Kaufman’s ion engine. SERT-I had one cesium engine and one mercury engine. The suborbital flight was only 50 minutes in duration but proved that the ion engine could operate in space. The Electric Propulsion Laboratory included two large space simulation chambers, one of which is seen here. Each uses twenty 2.6-foot diameter diffusion pumps, blowers, and roughing pumps to remove the air inside the tank to create the thin atmosphere. A helium refrigeration system simulates the cold temperatures of space.

  14. 7 CFR 91.37 - Standard hourly fee rate for laboratory testing, analysis, and other services.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Standard hourly fee rate for laboratory testing... AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.37 Standard hourly fee rate for laboratory testing, analysis, and other services. (a) The...

  15. 7 CFR 91.37 - Standard hourly fee rate for laboratory testing, analysis, and other services.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Standard hourly fee rate for laboratory testing... AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.37 Standard hourly fee rate for laboratory testing, analysis, and other services. (a) The...

  16. 7 CFR 91.37 - Standard hourly fee rate for laboratory testing, analysis, and other services.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Standard hourly fee rate for laboratory testing... AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.37 Standard hourly fee rate for laboratory testing, analysis, and other services. (a) The...

  17. 7 CFR 91.37 - Standard hourly fee rate for laboratory testing, analysis, and other services.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Standard hourly fee rate for laboratory testing... AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.37 Standard hourly fee rate for laboratory testing, analysis, and other services. (a) The...

  18. The Altitude Laboratory for the Test of Aircraft Engines

    NASA Technical Reports Server (NTRS)

    Dickinson, H C; Boutell, H G

    1920-01-01

    Report presents descriptions, schematics, and photographs of the altitude laboratory for the testing of aircraft engines constructed at the Bureau of Standards for the National Advisory Committee for Aeronautics.

  19. Laboratory Diagnosis and Susceptibility Testing for Mycobacterium tuberculosis.

    PubMed

    Procop, Gary W

    2016-12-01

    The laboratory, which utilizes some of the most sophisticated and rapidly changing technologies, plays a critical role in the diagnosis of tuberculosis. Some of these tools are being employed in resource-challenged countries for the rapid detection and characterization of Mycobacterium tuberculosis. Foremost, the laboratory defines appropriate specimen criteria for optimal test performance. The direct detection of mycobacteria in the clinical specimen, predominantly done by acid-fast staining, may eventually be replaced by rapid-cycle PCR. The widespread use of the Xpert MTB/RIF (Cepheid) assay, which detects both M. tuberculosis and key genetic determinants of rifampin resistance, is important for the early detection of multidrug-resistant strains. Culture, using both broth and solid media, remains the standard for establishing the laboratory-based diagnosis of tuberculosis. Cultured isolates are identified far less commonly by traditional biochemical profiling and more commonly by molecular methods, such as DNA probes and broad-range PCR with DNA sequencing. Non-nucleic acid-based methods of identification, such as high-performance liquid chromatography and, more recently, matrix-assisted laser desorption/ionization-time of flight mass spectrometry, may also be used for identification. Cultured isolates of M. tuberculosis should be submitted for susceptibility testing according to standard guidelines. The use of broth-based susceptibility testing is recommended to significantly decrease the time to result. Cultured isolates may also be submitted for strain typing for epidemiologic purposes. The use of massive parallel sequencing, also known as next-generation sequencing, promises to continue to this molecular revolution in mycobacteriology, as whole-genome sequencing provides identification, susceptibility, and typing information simultaneously.

  20. [Patient satisfaction in a laboratory test collection unit].

    PubMed

    de Moura, Gisela Maria Schebella Souto; Hilleshein, Eunice Fabiani; Schardosim, Juliana Machado; Delgado, Kátia Simone

    2008-06-01

    This exploratory descriptive study aimed at identifying customer satisfaction attributes in the field of laboratory tests. Data were collected in 2006, using 104 interviews in a laboratorial unit inside a teaching hospital, using the critical incident technique, and submitted to content analysis. Three attribute categories were identified: time spent in waiting for care, interpersonal contact, and technical skills. These results subsidize the assessment of the current satisfaction survey tool, and point to its reformulation. They also allow the identification of improvement needs in customer attention, and provide elements to be taken into account in personnel selection, training programs, personnel performance assessment.

  1. Utility of repeat testing of critical values: a Q-probes analysis of 86 clinical laboratories.

    PubMed

    Lehman, Christopher M; Howanitz, Peter J; Souers, Rhona; Karcher, Donald S

    2014-06-01

    A common laboratory practice is to repeat critical values before reporting the test results to the clinical care provider. This may be an unnecessary step that delays the reporting of critical test results without adding value to the accuracy of the test result. To determine the proportions of repeated chemistry and hematology critical values that differ significantly from the original value as defined by the participating laboratory, to determine the threshold differences defined by the laboratory as clinically significant, and to determine the additional time required to analyze the repeat test. Participants prospectively reviewed critical test results for 4 laboratory tests: glucose, potassium, white blood cell count, and platelet count. Participants reported the following information: initial and repeated test result; time initial and repeat results were first known to laboratory staff; critical result notification time; if the repeat result was still a critical result; if the repeat result was significantly different from the initial result, as judged by the laboratory professional or policy; significant difference threshold, as defined by the laboratory; the make and model of the instrument used for primary and repeat testing. Routine, repeat analysis of critical values is a common practice. Most laboratories did not formally define a significant difference between repeat results. Repeated results were rarely considered significantly different. Median repeated times were at least 17 to 21 minutes for 10% of laboratories. Twenty percent of laboratories reported at least 1 incident in the last calendar year of delayed result reporting that clinicians indicated had adversely affected patient care. Routine repeat analysis of automated chemistry and hematology critical values is unlikely to be clinically useful and may adversely affect patient care.

  2. [Unnecessary routine laboratory tests in patients referred for surgical services].

    PubMed

    Mata-Miranda, María del Pilar; Cano-Matus, Norberto; Rodriguez-Murrieta, Margarita; Guarneros-Zapata, Idalia; Ortiz, Mario

    2016-01-01

    To question the usefulness of the lab analysis considered routine testing for the identification of abnormalities in the surgical care. To determine the percentage of unnecessary laboratory tests in the preoperative assessment as well as to estimate the unnecessary expenses. A descriptive, cross-sectional study of patients referred for surgical evaluation between January 1st and March 31st 2013. The database of laboratory testing and electronic files were reviewed. Reference criteria from surgical services were compared with the tests requested by the family doctor. In 65% of the patients (n=175) unnecessary examinations were requested, 25% (n=68) were not requested the tests that they required, and only 10% of the patients were requested laboratory tests in accordance with the reference criteria (n=27). The estimated cost in unnecessary examinations was $1,129,552 in a year. The results were similar to others related to this theme, however, they had not been revised from the perspective of the first level of attention regarding the importance of adherence to the reference criteria which could prevent major expenditures. It is a priority for leaders and operational consultants in medical units to establish strategies and lines of action that ensure compliance with institutional policies so as to contain spending on comprehensive services, and which in turn can improve the medical care. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  3. 42 CFR 493.1481 - Condition: Laboratories performing high complexity testing; cytotechnologist.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing high complexity testing; cytotechnologist. 493.1481 Section 493.1481 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY...

  4. 42 CFR 493.1481 - Condition: Laboratories performing high complexity testing; cytotechnologist.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Laboratories performing high complexity testing; cytotechnologist. 493.1481 Section 493.1481 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY...

  5. [Contribution of HCV core antigen testing in HCV diagnosis by test from the company Abbott Laboratories].

    PubMed

    Trbusek, J

    2009-11-01

    Detection of HCV core antigen as direct marker of hepatitis C infection clearly improves diagnosis of this disease (especially reduction of window period) and brings broad clinical utilization. The company Abbott Laboratories offers fully automated laboratory test for measurement of HCV core antigen on ARCHITECT analyzers.

  6. 42 CFR 493.1467 - Condition: Laboratories performing high complexity testing; cytology general supervisor.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... testing; cytology general supervisor. 493.1467 Section 493.1467 Public Health CENTERS FOR MEDICARE....1467 Condition: Laboratories performing high complexity testing; cytology general supervisor. For the subspecialty of cytology, the laboratory must have a general supervisor who meets the qualification...

  7. 42 CFR 493.1467 - Condition: Laboratories performing high complexity testing; cytology general supervisor.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... testing; cytology general supervisor. 493.1467 Section 493.1467 Public Health CENTERS FOR MEDICARE....1467 Condition: Laboratories performing high complexity testing; cytology general supervisor. For the subspecialty of cytology, the laboratory must have a general supervisor who meets the qualification...

  8. 42 CFR 493.1467 - Condition: Laboratories performing high complexity testing; cytology general supervisor.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... testing; cytology general supervisor. 493.1467 Section 493.1467 Public Health CENTERS FOR MEDICARE....1467 Condition: Laboratories performing high complexity testing; cytology general supervisor. For the subspecialty of cytology, the laboratory must have a general supervisor who meets the qualification...

  9. 42 CFR 493.1467 - Condition: Laboratories performing high complexity testing; cytology general supervisor.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... testing; cytology general supervisor. 493.1467 Section 493.1467 Public Health CENTERS FOR MEDICARE....1467 Condition: Laboratories performing high complexity testing; cytology general supervisor. For the subspecialty of cytology, the laboratory must have a general supervisor who meets the qualification...

  10. 42 CFR 493.1467 - Condition: Laboratories performing high complexity testing; cytology general supervisor.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... testing; cytology general supervisor. 493.1467 Section 493.1467 Public Health CENTERS FOR MEDICARE....1467 Condition: Laboratories performing high complexity testing; cytology general supervisor. For the subspecialty of cytology, the laboratory must have a general supervisor who meets the qualification...

  11. Expert Assessment of Conditions for Accredited Quality Management System Functioning in Testing Laboratories

    NASA Astrophysics Data System (ADS)

    Mytych, Joanna; Ligarski, Mariusz J.

    2018-03-01

    The quality management systems compliant with the ISO 9001:2009 have been thoroughly researched and described in detail in the world literature. The accredited management systems used in the testing laboratories and compliant with the ISO/IEC 17025:2005 have been mainly described in terms of the system design and implementation. They have also been investigated from the analytical point of view. Unfortunately, a low number of studies concerned the management system functioning in the accredited testing laboratories. The aim of following study was to assess the management system functioning in the accredited testing laboratories in Poland. On 8 October 2015, 1,213 accredited testing laboratories were present in Poland. They investigated various scientific areas and substances/objects. There are more and more such laboratories that have various problems and different long-term experience when it comes to the implementation, maintenance and improvement of the management systems. The article describes the results of the conducted expert assessment (survey) carried out to examine the conditions for the functioning of a management system in an accredited laboratory. It also focuses on the characteristics of the accredited research laboratories in Poland. The authors discuss the selection of the external and internal conditions that may affect the accredited management system. They show how the experts assessing the selected conditions were chosen. The survey results are also presented.

  12. An analysis of reference laboratory (send out) testing: an 8-year experience in a large academic medical center.

    PubMed

    MacMillan, Donna; Lewandrowski, Elizabeth; Lewandrowski, Kent

    2004-01-01

    Utilization of outside reference laboratories for selected laboratory testing is common in the United States. However, relatively little data exist in the literature describing the scope and impact of these services. In this study, we reviewed use of reference laboratory testing at the Massachusetts General Hospital, a large urban academic medical center in Boston, Massachusetts. A retrospective review of hospital and laboratory administrative records over an 8-year period from fiscal years (FY) 1995-2002. Over the 8 years studied, reference laboratory expenses increased 4.2-fold and totaled 12.4% of the total laboratory budget in FY 2002. Total reference laboratory test volume increased 4-fold to 68,328 tests in FY 2002 but represented only 1.06% of the total test volume in the hospital. The menu of reference laboratory tests comprised 946 tests (65.7% of the hospital test menu) compared to 494 (34.3%) of tests performed in house. The average unit cost of reference laboratory tests was essentially unchanged but was approximately 13 times greater than the average unit cost in the hospital laboratory. Much of the growth in reference laboratory cost can be attributed to the addition of new molecular, genetic, and microbiological assays. Four of the top 10 tests with the highest total cost in 2002 were molecular diagnostic tests that were recently added to the test menu. Reference laboratory testing comprises a major component of hospital clinical laboratory services. Although send out tests represent a small percentage of the total test volume, these services account for the majority of the hospital laboratory test menu and a disproportionate percentage of laboratory costs.

  13. Policies and practices in haemostasis testing among laboratories in Croatia: a survey on behalf of a Working Group for Laboratory Coagulation of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    PubMed

    Bronić, Ana; Herak, Desiree Coen; Margetić, Sandra; Milić, Marija

    2017-02-15

    The objective of this survey was to assess current policies and practice in haemostasis testing among both hospital and outpatient laboratories in Republic of Croatia. A questionnaire with seventy questions divided into nine sections was created in May 2015. Participants were asked about their practice related to test request form, sample collection, prothrombin time (PT) and activated partial thromboplastin time assays, other individual haemostasis assays, point-of-care testing (POCT), reporting of coagulation tests results and quality assurance of procedures, the personnel and other laboratory resources, as well as on issues related to education and implementation of additional coagulation assays in their laboratory. The survey was administered and data were collected between June and September 2015. A total survey response rate was 104/170 (61.2%). Most respondents were faced with incomplete information on prescribed therapy and diagnosis on the test request or inappropriate samples withdrawn on distant locations, but also do not have protocols for handling samples with high haematocrit values. Reporting of PT-INR and D-dimer results was different between laboratories. Although almost all laboratories developed a critical value reporting system, reporting a value to general practitioners is still a problem. Result on coagulation POCT testing showed that not all devices were supervised by laboratories, which is not in compliance with Croatian Chamber of Medical Biochemistry acts. Obtained results highlighted areas that need improvement and different practice patterns in particular field of haemostasis testing among laboratories. A harmonization of the overall process of haemostasis testing at national level should be considered and undertaken.

  14. Diagnostic and laboratory test ordering in Northern Portuguese Primary Health Care: a cross-sectional study

    PubMed Central

    Sá, Luísa; Teixeira, Andreia Sofia Costa; Tavares, Fernando; Costa-Santos, Cristina; Couto, Luciana; Costa-Pereira, Altamiro; Hespanhol, Alberto Pinto; Santos, Paulo

    2017-01-01

    Objectives To characterise the test ordering pattern in Northern Portugal and to investigate the influence of context-related factors, analysing the test ordered at the level of geographical groups of family physicians and at the level of different healthcare organisations. Design Cross-sectional study. Setting Northern Primary Health Care, Portugal. Participants Records about diagnostic and laboratory tests ordered from 2035 family physicians working at the Northern Regional Health Administration, who served approximately 3.5 million Portuguese patients, in 2014. Outcomes To determine the 20 most ordered diagnostic and laboratory tests in the Northern Regional Health Administration; to identify the presence and extent of variations in the 20 most ordered diagnostic and laboratory tests between the Groups of Primary Care Centres and between health units; and to study factors that may explain these variations. Results The 20 most ordered diagnostic and laboratory tests almost entirely comprise laboratory tests and account for 70.9% of the total tests requested. We can trace a major pattern of test ordering for haemogram, glucose, lipid profile, creatinine and urinalysis. There was a significant difference (P<0.001) in test orders for all tests between Groups of Primary Care Centres and for all tests, except glycated haemoglobin (P=0.06), between health units. Generally, the Personalised Healthcare Units ordered more than Family Health Units. Conclusions The results from this study show that the most commonly ordered tests in Portugal are laboratory tests, that there is a tendency for overtesting and that there is a large variability in diagnostic and laboratory test ordering in different geographical and organisational Portuguese primary care practices, suggesting that there may be considerable potential for the rationalisation of test ordering. The existence of Family Health Units seems to be a strong determinant in decreasing test ordering by Portuguese family

  15. Continual planning and scheduling for managing patient tests in hospital laboratories.

    PubMed

    Marinagi, C C; Spyropoulos, C D; Papatheodorou, C; Kokkotos, S

    2000-10-01

    Hospital laboratories perform examination tests upon patients, in order to assist medical diagnosis or therapy progress. Planning and scheduling patient requests for examination tests is a complicated problem because it concerns both minimization of patient stay in hospital and maximization of laboratory resources utilization. In the present paper, we propose an integrated patient-wise planning and scheduling system which supports the dynamic and continual nature of the problem. The proposed combination of multiagent and blackboard architecture allows the dynamic creation of agents that share a set of knowledge sources and a knowledge base to service patient test requests.

  16. 42 CFR 493.807 - Condition: Reinstatement of laboratories performing nonwaived testing.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Reinstatement of laboratories performing nonwaived testing. 493.807 Section 493.807 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS...

  17. 42 CFR 493.807 - Condition: Reinstatement of laboratories performing nonwaived testing.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Reinstatement of laboratories performing nonwaived testing. 493.807 Section 493.807 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS...

  18. 42 CFR 493.1361 - Condition: Laboratories performing PPM procedures; testing personnel.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing PPM procedures; testing personnel. 493.1361 Section 493.1361 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS...

  19. 42 CFR 493.1361 - Condition: Laboratories performing PPM procedures; testing personnel.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Laboratories performing PPM procedures; testing personnel. 493.1361 Section 493.1361 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS...

  20. Association of Reference Pricing for Diagnostic Laboratory Testing With Changes in Patient Choices, Prices, and Total Spending for Diagnostic Tests.

    PubMed

    Robinson, James C; Whaley, Christopher; Brown, Timothy T

    2016-09-01

    Prices for laboratory and other clinical services vary widely. Employers and insurers increasingly are adopting "reference pricing" policies to create incentives for patients to select lower-priced facilities. To measure the association between implementation of reference pricing and patient choice of laboratory, test prices, patient out-of-pocket spending, and insurer spending. We conducted an observational study of changes in laboratory pricing and selection by employees of a large national grocery firm (n = 30 415) before and after the firm implemented a reference pricing policy for laboratory services and compared the findings with changes over the same period for policy holders of a large national insurer that did not implement reference pricing (n = 181 831). The grocery firm established a maximum payment limit at the 60th percentile of the distribution of prices for each laboratory test in each region. Employees were provided with data on prices at all laboratories through a mobile digital platform. Patients selecting a laboratory that charged more than the payment limit were required to pay the full difference themselves. A total of 2.13 million claims were analyzed for 285 types of in vitro diagnostic tests between 2010 and 2013. Patient choice of laboratory, price paid per test, patient out-of-pocket costs, and employer spending. Compared with trends in prices paid by insurance policy holders not subject to reference pricing, and after adjusting for characteristics of tests and patients, implementation of reference pricing was associated with a 31.9% reduction (95% CI, 20.6%-41.6%) in average price paid per test by the third year of the program. In these 3 years, total spending on laboratory tests declined by $2.57 million (95% CI, $1.59-$3.35 million). Out-of-pocket costs by patients declined by $1.05 million (95% CI, $0.73-$1.37 million). Spending by the employer declined by $1.70 million (95% CI, $0.92-$2.48 million). When combined with

  1. Beta-Testing Agreement | Frederick National Laboratory for Cancer Research

    Cancer.gov

    Beta-Testing Agreements are appropriate forlimited term evaluation and applications development of new software, technology, or equipment platforms by the Frederick National Laboratory in collaboration with an external commercial partner. It ma

  2. Crush Testing at Oak Ridge National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feldman, Matthew R

    2011-01-01

    The dynamic crush test is required in the certification testing of some small Type B transportation packages. International Atomic Energy Agency regulations state that the test article must be 'subjected to a dynamic crush test by positioning the specimen on the target so as to suffer maximum damage.' Oak Ridge National Laboratory (ORNL) Transportation Technologies Group performs testing of Type B transportation packages, including the crush test, at the National Transportation Research Center in Knoxville, Tennessee (United States). This paper documents ORNL's experiences performing crush tests on several different Type B packages. ORNL has crush tested five different drum-type packagemore » designs, continuing its 60 year history of RAM package testing. A total of 26 crush tests have been performed in a wide variety of package orientations and crush plate CG alignments. In all cases, the deformation of the outer drum created by the crush test was significantly greater than the deformation damage caused by the 9 m drop test. The crush test is a highly effective means for testing structural soundness of smaller nondense Type B shipping package designs. Further regulatory guidance could alleviate the need to perform the crush test in a wide range of orientations and crush plate CG alignments.« less

  3. Transferability and inter-laboratory variability assessment of the in vitro bovine oocyte fertilization test.

    PubMed

    Tessaro, Irene; Modina, Silvia C; Crotti, Gabriella; Franciosi, Federica; Colleoni, Silvia; Lodde, Valentina; Galli, Cesare; Lazzari, Giovanna; Luciano, Alberto M

    2015-01-01

    The dramatic increase in the number of animals required for reproductive toxicity testing imposes the validation of alternative methods to reduce the use of laboratory animals. As we previously demonstrated for in vitro maturation test of bovine oocytes, the present study describes the transferability assessment and the inter-laboratory variability of an in vitro test able to identify chemical effects during the process of bovine oocyte fertilization. Eight chemicals with well-known toxic properties (benzo[a]pyrene, busulfan, cadmium chloride, cycloheximide, diethylstilbestrol, ketoconazole, methylacetoacetate, mifepristone/RU-486) were tested in two well-trained laboratories. The statistical analysis demonstrated no differences in the EC50 values for each chemical in within (inter-runs) and in between-laboratory variability of the proposed test. We therefore conclude that the bovine in vitro fertilization test could advance toward the validation process as alternative in vitro method and become part of an integrated testing strategy in order to predict chemical hazards on mammalian fertility. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... in the 80000 series of the Current Procedural Terminology published by the American Medical... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  5. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Procedural Terminology published by the American Medical Association. (3) Levels of supervision. Except where... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  6. Quality performance of laboratory testing in pharmacies: a collaborative evaluation.

    PubMed

    Zaninotto, Martina; Miolo, Giorgia; Guiotto, Adriano; Marton, Silvia; Plebani, Mario

    2016-11-01

    The quality performance and the comparability between results of pharmacies point-of-care-testing (POCT) and institutional laboratories have been evaluated. Eight pharmacies participated in the project: a capillary specimen collected by the pharmacist and, simultaneously, a lithium-heparin sample drawn by a physician of laboratory medicine for the pharmacy customers (n=106) were analyzed in the pharmacy and in the laboratory, respectively. Glucose, cholesterol, HDL-cholesterol, triglycerides, creatinine, uric acid, aspartate aminotransferase, alanine aminotransferase, were measured using: Reflotron, n=5; Samsung, n=1; Cardiocheck PA, n=1; Cholestech LDX, n=1 and Cobas 8000. The POCT analytical performance only (phase 2) were evaluated testing, in pharmacies and in the laboratory, the lithium heparin samples from a female drawn fasting daily in a week, and a control sample containing high concentrations of glucose, cholesterol and triglycerides. For all parameters, except triglycerides, the slopes showed a satisfactory correlation. For triglycerides, a median value higher in POCT in comparison to the laboratory (1.627 mmol/L vs. 0.950 mmol/L) has been observed. The agreement in the subjects classification, demonstrates that for glucose, 70% of the subjects show concentrations below the POCT recommended level (5.8-6.1 mmol/L), while 56% are according to the laboratory limit (<5.6 mmol/L). Total cholesterol exhibits a similar trend while POCT triglycerides show a greater percentage of increased values (21% vs. 9%). The reduction in triglycerides bias (phase 2) suggests that differences between POCT and central laboratory is attributable to a pre-analytical problem. The results confirm the acceptable analytical performance of POCT pharmacies and specific criticisms in the pre- and post-analytical phases.

  7. ["How can hospitals develop a beneficial relationship with laboratory testing companies?" - Chairmen's introductory remarks].

    PubMed

    Morita, Toshisuke; Kawano, Seiji

    2014-12-01

    The symposium was held with the Japanese Society of Laboratory Medicine and JACLaP to discuss the way to develop a beneficial relationship between hospitals and laboratory testing companies with co-chairing by Seiji Kawano, Kobe University and Toshisuke Morita, Toho University. Clinical testing is considered to be essential for medical diagnosis and treatment; however, it is difficult for a hospital to perform all clinical testing for various reasons, including cost-effectiveness. In this session, 4 guest speakers gave a talk from their viewpoints. Doctor Kawano talked about the results of a questionnaire filled out by 114 university hospitals on how to develop a beneficial relationship between hospitalsoand laboratory testing companies. Next, Mr. Shinji Ogawa, president and CEO of SRL, talked about favorable ways to utilize laboratory testing companies, sayingthat such companies, which have a variety of skills, are expected to offer new and advanced technologies to hospitals continuously, and abundant data which laboratory testing companies have should be used for the advancement of community medicine. Professor Koshiba, Hyogo Medical School, expressed his apprehension to develop a so-called branch lab. in university hospitals from his own experience, and concluded that a beneficial relationship with companies to perform tasks required by hospitals should be sought. The last speaker, Yuichi Setoyama, Mitsubishi Chemical Medience, talked about the new relationship between hospitals and laboratory testing companies, and emphasized that hospitals and such companies should know the strong and weak points of each other and build a mutually complementary system. After all presentations were over, a discussion with participants was held. Doctors of clinics said that the role of laboratory testing companies for large hospitals is different from that for small clinics, and such companies are indispensable for his everyday medical activities. Each medical institute has its

  8. Thermal-Structures and Materials Testing Laboratory

    NASA Technical Reports Server (NTRS)

    Teate, Anthony A.

    1997-01-01

    Since its inception and successful implementation in 1997 at James Madison University, the Thermal Structures and Materials Testing Laboratory (T-SaMTL) funded by the NASA Langley Research Center is evolving into one of the University's premier and exemplary efforts to increase minority representation in the sciences and mathematics. Serving ten (10) students and faculty directly and almost fifty (50) students indirectly, T-SAMTL, through its recruitment efforts, workshops, mentoring program, tutorial services and its research and computational laboratories has marked the completion of the first year with support from NASA totaling $ 100,000. Beginning as an innovative academic research and mentoring program for underrepresented minority science and mathematics students, the program now boasts a constituency which consists of 50% graduating seniors in the spring of 1998 with 50% planning to go to graduate school. The program's intent is to increase the number of underrepresented minorities who receive doctoral degrees in the sciences by initiating an academically enriched research program aimed at strengthening the academic and self actualization skills of undergraduate students with the potential to pursue doctoral study in the sciences. The program provides financial assistance, academic enrichment, and professional and personal development support for minority students who demonstrate the potential and strong desire to pursue careers in the sciences and mathematics. James Madison University was awarded the first $100,000, in April 1997, by The NASA Langley Research Center for establishment and support of its Thermal Structures and Materials Testing

  9. Policies and practices in haemostasis testing among laboratories in Croatia: a survey on behalf of a Working Group for Laboratory Coagulation of the Croatian Society of Medical Biochemistry and Laboratory Medicine

    PubMed Central

    Bronić, Ana; Herak, Desiree Coen; Margetić, Sandra; Milić, Marija

    2017-01-01

    Introduction The objective of this survey was to assess current policies and practice in haemostasis testing among both hospital and outpatient laboratories in Republic of Croatia. Materials and methods A questionnaire with seventy questions divided into nine sections was created in May 2015. Participants were asked about their practice related to test request form, sample collection, prothrombin time (PT) and activated partial thromboplastin time assays, other individual haemostasis assays, point-of-care testing (POCT), reporting of coagulation tests results and quality assurance of procedures, the personnel and other laboratory resources, as well as on issues related to education and implementation of additional coagulation assays in their laboratory. The survey was administered and data were collected between June and September 2015. Results A total survey response rate was 104/170 (61.2%). Most respondents were faced with incomplete information on prescribed therapy and diagnosis on the test request or inappropriate samples withdrawn on distant locations, but also do not have protocols for handling samples with high haematocrit values. Reporting of PT-INR and D-dimer results was different between laboratories. Although almost all laboratories developed a critical value reporting system, reporting a value to general practitioners is still a problem. Result on coagulation POCT testing showed that not all devices were supervised by laboratories, which is not in compliance with Croatian Chamber of Medical Biochemistry acts. Conclusion Obtained results highlighted areas that need improvement and different practice patterns in particular field of haemostasis testing among laboratories. A harmonization of the overall process of haemostasis testing at national level should be considered and undertaken. PMID:28392741

  10. INTER LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON

    DTIC Science & Technology

    2018-03-26

    HELMET BLUNT IMPACT TEST METHOD COMPARISON by Tony J. Kayhart Charles A. Hewitt and Jonathan Cyganik March 2018 Final...Report March 2016 – August 2017 Approved for public release; distribution is unlimited U.S. Army Natick Soldier Research ...INTER-LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR

  11. Valid methods: the quality assurance of test method development, validation, approval, and transfer for veterinary testing laboratories.

    PubMed

    Wiegers, Ann L

    2003-07-01

    Third-party accreditation is a valuable tool to demonstrate a laboratory's competence to conduct testing. Accreditation, internationally and in the United States, has been discussed previously. However, accreditation is only I part of establishing data credibility. A validated test method is the first component of a valid measurement system. Validation is defined as confirmation by examination and the provision of objective evidence that the particular requirements for a specific intended use are fulfilled. The international and national standard ISO/IEC 17025 recognizes the importance of validated methods and requires that laboratory-developed methods or methods adopted by the laboratory be appropriate for the intended use. Validated methods are therefore required and their use agreed to by the client (i.e., end users of the test results such as veterinarians, animal health programs, and owners). ISO/IEC 17025 also requires that the introduction of methods developed by the laboratory for its own use be a planned activity conducted by qualified personnel with adequate resources. This article discusses considerations and recommendations for the conduct of veterinary diagnostic test method development, validation, evaluation, approval, and transfer to the user laboratory in the ISO/IEC 17025 environment. These recommendations are based on those of nationally and internationally accepted standards and guidelines, as well as those of reputable and experienced technical bodies. They are also based on the author's experience in the evaluation of method development and transfer projects, validation data, and the implementation of quality management systems in the area of method development.

  12. Can MOND type hypotheses be tested in a free fall laboratory environment?

    NASA Astrophysics Data System (ADS)

    Das, Saurya; Patitsas, S. N.

    2013-05-01

    The extremely small accelerations of objects required for the onset of modified Newtonian dynamics, or modified Newtonian dynamics (MOND), makes testing the hypothesis in conventional terrestrial laboratories virtually impossible. This is due to the large background acceleration of Earth, which is transmitted to the acceleration of test objects within an apparatus. We show, however, that it may be possible to test MOND-type hypotheses with experiments using a conventional apparatus capable of tracking very small accelerations of its components but performed in locally inertial frames such as artificial satellites and other freely falling laboratories. For example, experiments involving an optical interferometer or a torsion balance in these laboratories would show nonlinear dynamics and displacement amplitudes larger than expected. These experiments may also be able to test potential violations of the strong equivalence principle by MOND and to distinguish between its two possible interpretations (modified inertia and modified gravity).

  13. ChemCam for Mars Science Laboratory rover, undergoing pre-flight testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2011-10-20

    Los Alamos National Laboratory and partners developed a laser instrument, ChemCam, that will ride on the elevated mast of the Mars Science Laboratory rover Curiosity. The system allows Curiosity to "zap" rocks from a distance, reading their chemical composition through spectroscopic analysis. In this video, laboratory shaker-table testing of the instrument ensures that all of its components are solidly attached and resistant to damage from the rigors of launch, travel and landing.

  14. ChemCam for Mars Science Laboratory rover, undergoing pre-flight testing

    ScienceCinema

    None

    2018-06-06

    Los Alamos National Laboratory and partners developed a laser instrument, ChemCam, that will ride on the elevated mast of the Mars Science Laboratory rover Curiosity. The system allows Curiosity to "zap" rocks from a distance, reading their chemical composition through spectroscopic analysis. In this video, laboratory shaker-table testing of the instrument ensures that all of its components are solidly attached and resistant to damage from the rigors of launch, travel and landing.

  15. The changing face of hemostasis testing in modern laboratories: consolidation, automation, and beyond.

    PubMed

    Lippi, Giuseppe; Plebani, Mario; Favaloro, Emmanuel J

    2015-04-01

    The reality of laboratory diagnostics as a whole, and hemostasis testing in particular, is evolving under new paradigms of efficiency. The driving forces of health care and laboratory diagnostics in the third millennium are mainly represented by macro- and microeconomics. In a world with limited resources, shattered by an unprecedented economic crisis, laboratory diagnostics is undergoing a substantial reorganization, with emergence of new models under the imperative of terms, such as bedside testing, consolidation, and networking. The paradigms under which these changes are being developed include a variety of environment, preanalytical, technological, professional, and health-care aspects. The maintenance of continued quality is indeed the major challenge to be faced in the foreseeable future. In fact, some challenges prepotently emerge during a consolidation process, which basically involve delayed testing, centrifugation, transportation, and stability of the specimens, as well as the potential mismatch of sample matrix. This article is aimed to provide an overview of the current economic scenario of laboratory diagnostics and discuss the changing face of hemostasis testing in modern laboratories, providing a synthetic overview about potential drawbacks of actualized solutions. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  16. 76 FR 49491 - Medicare Program; Section 3113: The Treatment of Certain Complex Diagnostic Laboratory Tests...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-10

    ...] Medicare Program; Section 3113: The Treatment of Certain Complex Diagnostic Laboratory Tests Demonstration... code under the Treatment of Certain Complex Diagnostic Laboratory Tests Demonstration. The deadline for... interested parties of an opportunity to participate in the Treatment of Certain Complex Diagnostic Laboratory...

  17. [Approval of ISO/IEC 17025 and quality control of laboratory testing].

    PubMed

    Yamamoto, Shigeki; Asakura, Hiroshi; Machii, Kenji; Igimi, Shizunobu

    2010-01-01

    First section of Division of Biomedical Food Research, National Institute of Health Sciences (NIHS) was approved by ISO/IEC 17025 as a laboratory having an appropriate laboratory testing technique. NIHS is the first national laboratory approved by ISO/IEC 17025. NIHS has also been accepted the appropriate technique and facility for the BSL3 level pathogens by ISO/IEC 17025. NIHS is necessary to take an external audit almost every year. This approval is renewed every 4 years.

  18. Point-Counterpoint: The FDA Has a Role in Regulation of Laboratory-Developed Tests.

    PubMed

    Caliendo, Angela M; Hanson, Kimberly E

    2016-04-01

    Since the Food and Drug Administration (FDA) released its draft guidance on the regulation of laboratory-developed tests (LDTs) in October 2014, there has been a flurry of responses from commercial and hospital-based laboratory directors, clinicians, professional organizations, and diagnostic companies. The FDA defines an LDT as an "in vitrodiagnostic device that is intended for clinical use and is designed, manufactured, and used within a single laboratory." The draft guidance outlines a risk-based approach, with oversight of high-risk and moderate-risk tests being phased in over 9 years. High-risk tests would be regulated first and require premarket approval. Subsequently, moderate-risk tests would require a 510(k) premarket submission to the FDA and low-risk tests would need only to be registered. Oversight discretion would be exercised for LDTs focused on rare diseases (defined as fewer than 4,000 tests, not cases, per year nationally) and unmet clinical needs (defined as those tests for which there is no alternative FDA-cleared or -approved test). There was an open comment period followed by a public hearing in early January of 2015, and we are currently awaiting the final decision regarding the regulation of LDTs. Given that LDTs have been developed by many laboratories and are essential for the diagnosis and monitoring of an array of infectious diseases, changes in their regulation will have far-reaching implications for clinical microbiology laboratories. In this Point-Counterpoint, Angela Caliendo discusses the potential benefits of the FDA guidance for LDTs whereas Kim Hanson discusses the concerns associated with implementing the guidance and why these regulations may not improve clinical care. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  19. Implementation of a virtual laboratory for training on sound insulation testing and uncertainty calculations in acoustic tests.

    PubMed

    Asensio, C; Gasco, L; Ruiz, M; Recuero, M

    2015-02-01

    This paper describes a methodology and case study for the implementation of educational virtual laboratories for practice training on acoustic tests according to international standards. The objectives of this activity are (a) to help the students understand and apply the procedures described in the standards and (b) to familiarize the students with the uncertainty in measurement and its estimation in acoustics. The virtual laboratory will not focus on the handling and set-up of real acoustic equipment but rather on procedures and uncertainty. The case study focuses on the application of the virtual laboratory for facade sound insulation tests according to ISO 140-5:1998 (International Organization for Standardization, Geneva, Switzerland, 1998), and the paper describes the causal and stochastic models and the constraints applied in the virtual environment under consideration. With a simple user interface, the laboratory will provide measurement data that the students will have to process to report the insulation results that must converge with the "virtual true values" in the laboratory. The main advantage of the virtual laboratory is derived from the customization of factors in which the student will be instructed or examined (for instance, background noise correction, the detection of sporadic corrupted observations, and the effect of instrument precision).

  20. Mars Science Laboratory Boot Robustness Testing

    NASA Technical Reports Server (NTRS)

    Banazadeh, Payam; Lam, Danny

    2011-01-01

    Mars Science Laboratory (MSL) is one of the most complex spacecrafts in the history of mankind. Due to the nature of its complexity, a large number of flight software (FSW) requirements have been written for implementation. In practice, these requirements necessitate very complex and very precise flight software with no room for error. One of flight software's responsibilities is to be able to boot up and check the state of all devices on the spacecraft after the wake up process. This boot up and initialization is crucial to the mission success since any misbehavior of different devices needs to be handled through the flight software. I have created a test toolkit that allows the FSW team to exhaustively test the flight software under variety of different unexpected scenarios and validate that flight software can handle any situation after booting up. The test includes initializing different devices on spacecraft to different configurations and validate at the end of the flight software boot up that the flight software has initialized those devices to what they are suppose to be in that particular scenario.

  1. The development of Metacognition test in genetics laboratory for undergraduate students

    NASA Astrophysics Data System (ADS)

    A-nongwech, Nattapong; Pruekpramool, Chaninan

    2018-01-01

    The purpose of this research was to develop a Metacognition test in a Genetics Laboratory for undergraduate students. The participants were 30 undergraduate students of a Rajabhat university in Rattanakosin group in the second semester of the 2016 academic year using purposive sampling. The research instrument consisted of 1) Metacognition test and 2) a Metacognition test evaluation form for experts focused on three main points which were an accurate evaluation form of content, a consistency between Metacognition experiences and questions and the appropriateness of the test. The quality of the test was analyzed by using the Index of Consistency (IOC), discrimination and reliability. The results of developing Metacognition test were summarized as 1) The result of developing Metacognition test in a Genetics Laboratory for undergraduate students found that the Metacognition test contained 56 items of open - ended questions. The test composed of 1) four scientific situations, 2) fourteen items of open - ended questions in each scientific situation for evaluating components of Metacognition. The components of Metacognition consisted of Metacognitive knowledge, which were divided into person knowledge, task knowledge and strategy knowledge and Metacognitive experience, which were divided into planning, monitoring and evaluating, and 3) fourteen items of scoring criteria divided into four scales. 2) The results of the item analysis of Metacognition in Genetics Laboratory for undergraduate students found that Index of Consistency between Metacognitive experiences and questions were in the range between 0.75 - 1.00. An accuracy of content equaled 1.00. The appropriateness of the test equaled 1.00 in all situations and items. The discrimination of the test was in the range between 0.00 - 0.73. Furthermore, the reliability of the test equaled 0.97.

  2. 23 CFR 637.209 - Laboratory and sampling and testing personnel qualifications.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... sampling and testing personnel. (c) Conflict of interest. In order to avoid an appearance of a conflict of interest, any qualified non-STD laboratory shall perform only one of the following types of testing on the...

  3. Laboratory testing in management of patients with suspected Ebolavirus disease: infection control and safety.

    PubMed

    Gilbert, G L

    2015-08-01

    If routine laboratory safety precautions are followed, the risk of laboratory-acquired infection from handling specimens from patients with Ebolavirus disease (EVD) is very low, especially in the early 'dry' stage of disease. In Australia, border screening to identify travellers returning from EVD-affected west African countries during the 2014-2015 outbreak has made it unlikely that specimens from patients with unrecognised EVD would be sent to a routine diagnostic laboratory. Australian public health and diagnostic laboratories associated with hospitals designated for the care of patients with EVD have developed stringent safety precautions for EVD diagnostic and other tests likely to be required for supportive care of the sickest (and most infectious) patients with EVD, including as wide a range of point-of-care tests as possible. However, it is important that the stringent requirements for packaging, transport and testing of specimens that might contain Ebolavirus--which is a tier 1 security sensitive biology agent--do not delay the diagnosis and appropriate management of other potentially serious but treatable infectious diseases, which are far more likely causes of a febrile illness in people returning from west Africa. If necessary, urgent haematology, biochemistry and microbiological tests can be performed safely, whilst awaiting the results of EVD tests, in a PC-2 laboratory with appropriate precautions including: use of recommended personal protective equipment (PPE) for laboratory staff; handling any unsealed specimens in a class 1 or II biosafety cabinet; using only centrifuges with sealed rotors; and safe disposal or decontamination of all used equipment and laboratory waste.

  4. 9 CFR 54.11 - Approval of laboratories to run official scrapie tests and official genotype tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... request approval to conduct one or more types of scrapie test or genotype test on one or more types of... type of test and for each type of tissue for which they request approval. (c) The Administrator may... the laboratory and shall give the director an opportunity to respond. If there are conflicts as to any...

  5. 42 CFR 493.1459 - Condition: Laboratories performing high complexity testing; general supervisor.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Laboratories performing high complexity testing; general supervisor. 493.1459 Section 493.1459 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY...

  6. 42 CFR 493.1453 - Condition: Laboratories performing high complexity testing; clinical consultant.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Laboratories performing high complexity testing; clinical consultant. 493.1453 Section 493.1453 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY...

  7. 42 CFR 493.1447 - Condition: Laboratories performing high complexity testing; technical supervisor.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Laboratories performing high complexity testing; technical supervisor. 493.1447 Section 493.1447 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY...

  8. 42 CFR 493.1459 - Condition: Laboratories performing high complexity testing; general supervisor.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing high complexity testing; general supervisor. 493.1459 Section 493.1459 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY...

  9. 42 CFR 493.1447 - Condition: Laboratories performing high complexity testing; technical supervisor.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing high complexity testing; technical supervisor. 493.1447 Section 493.1447 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY...

  10. Characterization of Orbital Debris via Hyper-Velocity Laboratory-Based Tests

    NASA Technical Reports Server (NTRS)

    Cowardin, Heather; Liou, J.-C.; Anz-Meador, Phillip; Sorge, Marlon; Opiela, John; Fitz-Coy, Norman; Huynh, Tom; Krisko, Paula

    2017-01-01

    Existing DOD and NASA satellite breakup models are based on a key laboratory test, Satellite Orbital debris Characterization Impact Test (SOCIT), which has supported many applications and matched on-orbit events involving older satellite designs reasonably well over the years. In order to update and improve these models, the NASA Orbital Debris Program Office, in collaboration with the Air Force Space and Missile Systems Center, The Aerospace Corporation, and the University of Florida, replicated a hypervelocity impact using a mock-up satellite, DebriSat, in controlled laboratory conditions. DebriSat is representative of present-day LEO satellites, built with modern spacecraft materials and construction techniques. Fragments down to 2 mm in size will be characterized by their physical and derived properties. A subset of fragments will be further analyzed in laboratory radar and optical facilities to update the existing radar-based NASA Size Estimation Model (SEM) and develop a comparable optical-based SEM. A historical overview of the project, status of the characterization process, and plans for integrating the data into various models will be discussed herein.

  11. Characterization of Orbital Debris via Hyper-Velocity Laboratory-Based Tests

    NASA Technical Reports Server (NTRS)

    Cowardin, Heather; Liou, J.-C.; Krisko, Paula; Opiela, John; Fitz-Coy, Norman; Sorge, Marlon; Huynh, Tom

    2017-01-01

    Existing DoD and NASA satellite breakup models are based on a key laboratory test, Satellite Orbital debris Characterization Impact Test (SOCIT), which has supported many applications and matched on-orbit events involving older satellite designs reasonably well over the years. In order to update and improve these models, the NASA Orbital Debris Program Office, in collaboration with the Air Force Space and Missile Systems Center, The Aerospace Corporation, and the University of Florida, replicated a hypervelocity impact using a mock-up satellite, DebriSat, in controlled laboratory conditions. DebriSat is representative of present-day LEO satellites, built with modern spacecraft materials and construction techniques. Fragments down to 2 mm in size will be characterized by their physical and derived properties. A subset of fragments will be further analyzed in laboratory radar and optical facilities to update the existing radar-based NASA Size Estimation Model (SEM) and develop a comparable optical-based SEM. A historical overview of the project, status of the characterization process, and plans for integrating the data into various models will be discussed herein.

  12. An Alternative to the Physiological Psychology Laboratory: Identification of an Unknown Drug Through Behavioral Testing.

    ERIC Educational Resources Information Center

    Schumacher, Susan J.

    1982-01-01

    A laboratory project introduced physiological psychology students to research by requiring them to identify an unknown drug given to laboratory animals. Students read material about drugs and animal drug studies, designed behavioral tests, constructed the testing apparatus, conducted the tests, and wrote progress reports. (SR)

  13. US Highway 84 chip seal field trials and laboratory test results.

    DOT National Transportation Integrated Search

    2009-03-23

    This report contains laboratory and field testing of US Highway 84 in Lincoln county Mississippi. A full scale field test consisting of seven polymer modified asphalt emulsions and a CRS-2 control emulsion was constructed in September of 1989 and sub...

  14. Study of LTPP laboratory resilient modulus test data and response characteristics.

    DOT National Transportation Integrated Search

    2002-10-01

    The resilient modulus of every unbound structural layer of the Long Term Pavement Performance (LTPP) Specific Pavement and : General Pavement Studies Test Sections is being measured in the laboratory using LTPP test protocol P46. A total of 2,014 : r...

  15. Potential over request in anemia laboratory tests in primary care in Spain.

    PubMed

    Salinas, María; López-Garrigós, Maite; Flores, Emilio; Uris, Joaquín; Leiva-Salinas, Carlos

    2015-07-01

    The aim was to study the inter-practice variability in anemia laboratory tests requested by general practitioners in Spain, to evaluate for a potential requesting inappropriateness. Laboratories from diverse Spanish regions filled out the number of cell blood count, ferritin, folate, iron, transferrin, and vitamin B12 requested by general practitioners during 2012. The number of test requests per 1000 inhabitants and ratios of related tests requests were calculated. The results obtained in hospitals from different areas (urban, rural, or urban-rural), type of management (public or private), and geographic regions were compared. There was a high variability in the number of test requests and ratios of related tests. Cell blood count was over requested in rural areas and in hospitals with private management. Andalucía was the community with the lowest number of iron requests and the lowest folate/vitamin B12 indicator value. Iron and transferrin seemed over requested in some areas; as were folate and ferritin when compared to vitamin B12 and cell blood count, respectively. The differences observed between areas indicate that other factors besides clinical reasons could be behind that variability and emphasize the need to accomplish interventions to improve the appropriate use of anemia laboratory tests.

  16. Specimen origin, type and testing laboratory are linked to longer turnaround times for HIV viral load testing in Malawi

    PubMed Central

    Chipungu, Geoffrey; Kim, Andrea A.; Sarr, Abdoulaye; Ali, Hammad; Mwenda, Reuben; Nkengasong, John N.; Singer, Daniel

    2017-01-01

    Background Efforts to reach UNAIDS’ treatment and viral suppression targets have increased demand for viral load (VL) testing and strained existing laboratory networks, affecting turnaround time. Longer VL turnaround times delay both initiation of formal adherence counseling and switches to second-line therapy for persons failing treatment and contribute to poorer health outcomes. Methods We utilized descriptive statistics and logistic regression to analyze VL testing data collected in Malawi between January 2013 and March 2016. The primary outcomes assessed were greater-than-median pretest phase turnaround time (days elapsed from specimen collection to receipt at the laboratory) and greater-than-median test phase turnaround time (days from receipt to testing). Results The median number of days between specimen collection and testing increased 3-fold between 2013 (8 days, interquartile range (IQR) = 6–16) and 2015 (24, IQR = 13–39) (p<0.001). Multivariable analysis indicated that the odds of longer pretest phase turnaround time were significantly higher for specimen collection districts without laboratories capable of conducting viral load tests (adjusted odds ratio (aOR) = 5.16; 95% confidence interval (CI) = 5.04–5.27) as well as for Malawi’s Northern and Southern regions. Longer test phase turnaround time was significantly associated with use of dried blood spots instead of plasma (aOR = 2.30; 95% CI = 2.23–2.37) and for certain testing months and testing laboratories. Conclusion Increased turnaround time for VL testing appeared to be driven in part by categorical factors specific to the phase of turnaround time assessed. Given the implications of longer turnaround time and the global effort to scale up VL testing, addressing these factors via increasing efficiencies, improving quality management systems and generally strengthening the VL spectrum should be considered essential components of controlling the HIV epidemic. PMID:28235013

  17. ASVCP quality assurance guidelines: external quality assessment and comparative testing for reference and in-clinic laboratories.

    PubMed

    Camus, Melinda S; Flatland, Bente; Freeman, Kathleen P; Cruz Cardona, Janice A

    2015-12-01

    The purpose of this document is to educate providers of veterinary laboratory diagnostic testing in any setting about comparative testing. These guidelines will define, explain, and illustrate the importance of a multi-faceted laboratory quality management program which includes comparative testing. The guidelines will provide suggestions for implementation of such testing, including which samples should be tested, frequency of testing, and recommendations for result interpretation. Examples and a list of vendors and manufacturers supplying control materials and services to veterinary laboratories are also included. © 2015 American Society for Veterinary Clinical Pathology.

  18. 78 FR 22536 - Procedural Manual for the Election Assistance Commission's Voting System Test Laboratories...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-16

    ... System Test Laboratories Program Manual, Version 2.0 AGENCY: United States Election Assistance Commission (EAC). ACTION: Notice; publication of Voting System Test Laboratories Program Manual, Version 2.0, for 60 day public comment period on EAC Web site. SUMMARY: The U.S. Election Assistance Commission (EAC...

  19. 75 FR 39954 - Oversight of Laboratory Developed Tests; Public Meeting; Change of Meeting Location

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-13

    ...] Oversight of Laboratory Developed Tests; Public Meeting; Change of Meeting Location AGENCY: Food and Drug... location for the upcoming public meeting entitled ``Oversight of Laboratory Developed Tests.'' A new... the public meeting, FDA is announcing in this notice a new location for the public meeting. II. New...

  20. An examination of the usefulness of repeat testing practices in a large hospital clinical chemistry laboratory.

    PubMed

    Deetz, Carl O; Nolan, Debra K; Scott, Mitchell G

    2012-01-01

    A long-standing practice in clinical laboratories has been to automatically repeat laboratory tests when values trigger automated "repeat rules" in the laboratory information system such as a critical test result. We examined 25,553 repeated laboratory values for 30 common chemistry tests from December 1, 2010, to February 28, 2011, to determine whether this practice is necessary and whether it may be possible to reduce repeat testing to improve efficiency and turnaround time for reporting critical values. An "error" was defined to occur when the difference between the initial and verified values exceeded the College of American Pathologists/Clinical Laboratory Improvement Amendments allowable error limit. The initial values from 2.6% of all repeated tests (668) were errors. Of these 668 errors, only 102 occurred for values within the analytic measurement range. Median delays in reporting critical values owing to repeated testing ranged from 5 (blood gases) to 17 (glucose) minutes.

  1. Impact of providing fee data on laboratory test ordering: a controlled clinical trial.

    PubMed

    Feldman, Leonard S; Shihab, Hasan M; Thiemann, David; Yeh, Hsin-Chieh; Ardolino, Margaret; Mandell, Steven; Brotman, Daniel J

    2013-05-27

    Inpatient care providers often order laboratory tests without any appreciation for the costs of the tests. To determine whether we could decrease the number of laboratory tests ordered by presenting providers with test fees at the time of order entry in a tertiary care hospital, without adding extra steps to the ordering process. Controlled clinical trial. Tertiary care hospital. All providers, including physicians and nonphysicians, who ordered laboratory tests through the computerized provider order entry system at The Johns Hopkins Hospital. We randomly assigned 61 diagnostic laboratory tests to an "active" arm (fee displayed) or to a control arm (fee not displayed). During a 6-month baseline period (November 10, 2008, through May 9, 2009), we did not display any fee data. During a 6-month intervention period 1 year later (November 10, 2009, through May 9, 2010), we displayed fees, based on the Medicare allowable fee, for active tests only. We examined changes in the total number of orders placed, the frequency of ordered tests (per patient-day), and total charges associated with the orders according to the time period (baseline vs intervention period) and by study group (active test vs control). For the active arm tests, rates of test ordering were reduced from 3.72 tests per patient-day in the baseline period to 3.40 tests per patient-day in the intervention period (8.59% decrease; 95% CI, -8.99% to -8.19%). For control arm tests, ordering increased from 1.15 to 1.22 tests per patient-day from the baseline period to the intervention period (5.64% increase; 95% CI, 4.90% to 6.39%) (P < .001 for difference over time between active and control tests). Presenting fee data to providers at the time of order entry resulted in a modest decrease in test ordering. Adoption of this intervention may reduce the number of inappropriately ordered diagnostic tests.

  2. Automation software for a materials testing laboratory

    NASA Technical Reports Server (NTRS)

    Mcgaw, Michael A.; Bonacuse, Peter J.

    1990-01-01

    The software environment in use at the NASA-Lewis Research Center's High Temperature Fatigue and Structures Laboratory is reviewed. This software environment is aimed at supporting the tasks involved in performing materials behavior research. The features and capabilities of the approach to specifying a materials test include static and dynamic control mode switching, enabling multimode test control; dynamic alteration of the control waveform based upon events occurring in the response variables; precise control over the nature of both command waveform generation and data acquisition; and the nesting of waveform/data acquisition strategies so that material history dependencies may be explored. To eliminate repetitive tasks in the coventional research process, a communications network software system is established which provides file interchange and remote console capabilities.

  3. Reduction in Unnecessary Clinical Laboratory Testing Through Utilization Management at a US Government Veterans Affairs Hospital.

    PubMed

    Konger, Raymond L; Ndekwe, Paul; Jones, Genea; Schmidt, Ronald P; Trey, Marty; Baty, Eric J; Wilhite, Denise; Munshi, Imtiaz A; Sutter, Bradley M; Rao, Maddamsetti; Bashir, Chowdry M

    2016-03-01

    To implement an electronic laboratory utilization management system (laboratory expert system [LES]) to provide safe and effective reductions in unnecessary clinical laboratory testing. The LES is a set of frequency filter subroutines within the Veterans Affairs hospital and laboratory information system that was formulated by an interdisciplinary medical team. Since implementing the LES, total test volume has decreased by a mean of 11.18% per year compared with our pre-LES test volume. This change was not attributable to fluctuations in outpatient visits or inpatient days of care. Laboratory cost savings were estimated at $151,184 and $163,751 for 2012 and 2013, respectively. A significant portion of these cost savings was attributable to reductions in high-volume, large panel testing. No adverse effects on patient care were reported, and mean length of stay for patients remained unchanged. Electronic laboratory utilization systems can effectively reduce unnecessary laboratory testing without compromising patient care. Published by Oxford University Press on behalf of the American Society for Clinical Pathology, 2016. This work is written by US Government employees and is in the public domain in the US.

  4. Clinical Variant Classification: A Comparison of Public Databases and a Commercial Testing Laboratory.

    PubMed

    Gradishar, William; Johnson, KariAnne; Brown, Krystal; Mundt, Erin; Manley, Susan

    2017-07-01

    There is a growing move to consult public databases following receipt of a genetic test result from a clinical laboratory; however, the well-documented limitations of these databases call into question how often clinicians will encounter discordant variant classifications that may introduce uncertainty into patient management. Here, we evaluate discordance in BRCA1 and BRCA2 variant classifications between a single commercial testing laboratory and a public database commonly consulted in clinical practice. BRCA1 and BRCA2 variant classifications were obtained from ClinVar and compared with the classifications from a reference laboratory. Full concordance and discordance were determined for variants whose ClinVar entries were of the same pathogenicity (pathogenic, benign, or uncertain). Variants with conflicting ClinVar classifications were considered partially concordant if ≥1 of the listed classifications agreed with the reference laboratory classification. Four thousand two hundred and fifty unique BRCA1 and BRCA2 variants were available for analysis. Overall, 73.2% of classifications were fully concordant and 12.3% were partially concordant. The remaining 14.5% of variants had discordant classifications, most of which had a definitive classification (pathogenic or benign) from the reference laboratory compared with an uncertain classification in ClinVar (14.0%). Here, we show that discrepant classifications between a public database and single reference laboratory potentially account for 26.7% of variants in BRCA1 and BRCA2 . The time and expertise required of clinicians to research these discordant classifications call into question the practicality of checking all test results against a database and suggest that discordant classifications should be interpreted with these limitations in mind. With the increasing use of clinical genetic testing for hereditary cancer risk, accurate variant classification is vital to ensuring appropriate medical management

  5. GATE AND VACUUM FLUSHING OF SEWER SEDIMENT: LABORATORY TESTING

    EPA Science Inventory

    The objective of this study was to test the performance of a traditional gate-flushing device and a newly-designed vacuum-flushing device in removing sediment from combined sewers and CSO storage tanks. A laboratory hydraulic flume was used to simulate a reach of sewer or storag...

  6. Combined ultraviolet and water exposure as a preconditioning method in laboratory fungal durability testing

    Treesearch

    Rebecca E. Ibach; Craig M. Clemons; Nicole M. Stark

    2003-01-01

    During outdoor exposure, woodfiber-plastic composites (WPC) are subject to biological, moisture, and ultraviolet (UV) degradation. The purpose of laboratory evaluations is to simulate outdoor conditions and accelerate the testing for quicker results. Traditionally, biological, moisture, and W laboratory tests are done separately, and only combined in outdoor field...

  7. Evaluating performance in sweat testing in medical biochemistry laboratories in Croatia.

    PubMed

    Aralica, Merica; Krleza, Jasna Lenicek

    2017-02-15

    Sweat test has a diagnostic role in evaluation of cystic fibrosis. Its performance includes sweat stimulation, collection and analysis. All listed may be sources of inconsistencies in everyday practice. The aim of this study was an evaluation of external quality assessment (EQA) of sweat chloride measurement including sweat test performance in medical biochemistry laboratories in Croatia. EQA for sweat chloride measurement was provided by Croatian Centre for Quality Assessment in Laboratory Medicine (CROQALM) in five consecutive exercises to medical biochemistry laboratories (MBL) that offered sweat testing. A questionnaire regarding all phases of testing was mailed to involved MBL (N = 10). Survey results were compared to current guidelines for sweat test performance. Reported results of EQA in 2015 exercises showed coefficients of variation (CV) from 28.9%, 29.0% to 35.3%, respectively. An introduction of uniform sweat chloride measurement protocol resulted in CV of 15.5% and 14.7% reported in following two exercises in 2016. All MBL included in this study replied to the questionnaire. Results reported by MBL indicated: lack of patient information policy (7/10), use of unacceptable electrodes (6/9), misuse of minimum of acceptable sweat weight (6/9), lack of internal quality assessment (5/9) and recommended reference ranges (5/9 and 4/9). Agreements to guidelines were found in approach to unsuitable patients (9/10) and sweat collection (8/9). Presented results indicate major weak points of current practice in sweat test performance in Croatian MBL and stress the need for its standardization on a national level.

  8. Evaluating performance in sweat testing in medical biochemistry laboratories in Croatia

    PubMed Central

    Aralica, Merica; Krleza, Jasna Lenicek

    2017-01-01

    Introduction Sweat test has a diagnostic role in evaluation of cystic fibrosis. Its performance includes sweat stimulation, collection and analysis. All listed may be sources of inconsistencies in everyday practice. The aim of this study was an evaluation of external quality assessment (EQA) of sweat chloride measurement including sweat test performance in medical biochemistry laboratories in Croatia. Materials and methods EQA for sweat chloride measurement was provided by Croatian Centre for Quality Assessment in Laboratory Medicine (CROQALM) in five consecutive exercises to medical biochemistry laboratories (MBL) that offered sweat testing. A questionnaire regarding all phases of testing was mailed to involved MBL (N = 10). Survey results were compared to current guidelines for sweat test performance. Results Reported results of EQA in 2015 exercises showed coefficients of variation (CV) from 28.9%, 29.0% to 35.3%, respectively. An introduction of uniform sweat chloride measurement protocol resulted in CV of 15.5% and 14.7% reported in following two exercises in 2016. All MBL included in this study replied to the questionnaire. Results reported by MBL indicated: lack of patient information policy (7/10), use of unacceptable electrodes (6/9), misuse of minimum of acceptable sweat weight (6/9), lack of internal quality assessment (5/9) and recommended reference ranges (5/9 and 4/9). Agreements to guidelines were found in approach to unsuitable patients (9/10) and sweat collection (8/9). Conclusion Presented results indicate major weak points of current practice in sweat test performance in Croatian MBL and stress the need for its standardization on a national level. PMID:28392735

  9. 42 CFR 414.506 - Procedures for public consultation for payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... a new clinical diagnostic laboratory test. 414.506 Section 414.506 Public Health CENTERS FOR... FOR PART B MEDICAL AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.506 Procedures for public consultation for payment for a new clinical diagnostic laboratory test...

  10. 42 CFR 414.506 - Procedures for public consultation for payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... a new clinical diagnostic laboratory test. 414.506 Section 414.506 Public Health CENTERS FOR... FOR PART B MEDICAL AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.506 Procedures for public consultation for payment for a new clinical diagnostic laboratory test...

  11. A Unique Testing System for Audio Visual Foreign Language Laboratory.

    ERIC Educational Resources Information Center

    Stama, Spelios T.

    1980-01-01

    Described is the design of a low maintenance, foreign language laboratory at Ithaca College, New York, that provides visual and audio instruction, flexibility for testing, and greater student involvement in the lessons. (Author/CS)

  12. The quality and scope of information provided by medical laboratories to patients before laboratory testing: Survey of the Working Group for Patient Preparation of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    PubMed

    Nikolac, Nora; Simundic, Ana-Maria; Kackov, Sanja; Serdar, Tihana; Dorotic, Adrijana; Fumic, Ksenija; Gudasic-Vrdoljak, Jelena; Klenkar, Kornelija; Sambunjak, Jadranka; Vidranski, Valentina

    2015-10-23

    The aim of this work was to evaluate to what extent the scope and content of information provided to patients is standardized across medical biochemistry laboratories in Croatia. Two on-line self-report surveys were sent out: Survey A regarding attitudes on importance of patient preparation and Survey B on the contents of patient preparation instructions. 13/118 laboratories (11%) do not provide written instructions to patients on how to prepare for laboratory testing, and 36 (40%) do not include information about water intake in their instructions. Only half of laboratories provide instructions for prostate-specific antigen (53.8%), female sex hormones (53.7%) and therapeutic drug monitoring (TDM) (52.5%). Inadequate information about fasting status (55.0%) and 24 hour urine collection (77.9%) were frequent errors with high severity and were associated with the greatest potential to cause patient harm. Laboratory professionals in Croatia have a positive attitude towards the importance of patient preparation for laboratory testing. However, the information for laboratory testing is not standardized and frequently lacks guidance for tests related to TDM, coagulation and endocrinology. This study highlights the need for standardized, updated and evidence-based recommendations for patient preparation in order to minimize the risk for patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. CERTS Microgrid Laboratory Test Bed - PIER Final Project Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eto, Joseph H.; Eto, Joseph H.; Lasseter, Robert

    2008-07-25

    The objective of the CERTS Microgrid Laboratory Test Bed project was to enhance the ease of integrating small energy sources into a microgrid. The project accomplished this objective by developing and demonstrating three advanced techniques, collectively referred to as the CERTS Microgrid concept, that significantly reduce the level of custom field engineering needed to operate microgrids consisting of small generating sources. The techniques comprising the CERTS Microgrid concept are: 1) a method for effecting automatic and seamless transitions between grid-connected and islanded modes of operation; 2) an approach to electrical protection within the microgrid that does not depend on highmore » fault currents; and 3) a method for microgrid control that achieves voltage and frequency stability under islanded conditions without requiring high-speed communications. The techniques were demonstrated at a full-scale test bed built near Columbus, Ohio and operated by American Electric Power. The testing fully confirmed earlier research that had been conducted initially through analytical simulations, then through laboratory emulations, and finally through factory acceptance testing of individual microgrid components. The islanding and resychronization method met all Institute of Electrical and Electronics Engineers 1547 and power quality requirements. The electrical protections system was able to distinguish between normal and faulted operation. The controls were found to be robust and under all conditions, including difficult motor starts. The results from these test are expected to lead to additional testing of enhancements to the basic techniques at the test bed to improve the business case for microgrid technologies, as well to field demonstrations involving microgrids that involve one or mroe of the CERTS Microgrid concepts.« less

  14. Geographically distributed hybrid testing & collaboration between geotechnical centrifuge and structures laboratories

    NASA Astrophysics Data System (ADS)

    Ojaghi, Mobin; Martínez, Ignacio Lamata; Dietz, Matt S.; Williams, Martin S.; Blakeborough, Anthony; Crewe, Adam J.; Taylor, Colin A.; Madabhushi, S. P. Gopal; Haigh, Stuart K.

    2018-01-01

    Distributed Hybrid Testing (DHT) is an experimental technique designed to capitalise on advances in modern networking infrastructure to overcome traditional laboratory capacity limitations. By coupling the heterogeneous test apparatus and computational resources of geographically distributed laboratories, DHT provides the means to take on complex, multi-disciplinary challenges with new forms of communication and collaboration. To introduce the opportunity and practicability afforded by DHT, here an exemplar multi-site test is addressed in which a dedicated fibre network and suite of custom software is used to connect the geotechnical centrifuge at the University of Cambridge with a variety of structural dynamics loading apparatus at the University of Oxford and the University of Bristol. While centrifuge time-scaling prevents real-time rates of loading in this test, such experiments may be used to gain valuable insights into physical phenomena, test procedure and accuracy. These and other related experiments have led to the development of the real-time DHT technique and the creation of a flexible framework that aims to facilitate future distributed tests within the UK and beyond. As a further example, a real-time DHT experiment between structural labs using this framework for testing across the Internet is also presented.

  15. Development, integrated investigation, laboratory and in-flight testing of Chibis-M microsatellite ADCS

    NASA Astrophysics Data System (ADS)

    Ovchinnikov, M. Yu.; Ivanov, D. S.; Ivlev, N. A.; Karpenko, S. O.; Roldugin, D. S.; Tkachev, S. S.

    2014-01-01

    Design, analytical investigation, laboratory and in-flight testing of the attitude determination and control system (ADCS) of a microsatellites are considered. The system consists of three pairs of reaction wheels, three magnetorquers, a set of Sun sensors, a three-axis magnetometer and a control unit. The ADCS is designed for a small 10-50 kg LEO satellite. System development is accomplished in several steps: satellite dynamics preliminary study using asymptotical and numerical techniques, hardware and software design, laboratory testing of each actuator and sensor and the whole ADCS. Laboratory verification is carried out on the specially designed test-bench. In-flight ADCS exploitation results onboard the Russian microsatellite "Chibis-M" are presented. The satellite was developed, designed and manufactured by the Institute of Space Research of RAS. "Chibis-M" was launched by the "Progress-13M" cargo vehicle on January 25, 2012 after undocking from the International Space Station (ISS). This paper assess both the satellite and the ADCS mock-up dynamics. Analytical, numerical and laboratory study results are in good correspondence with in-flight data.

  16. An electronic thesaurus of Evidence Based Laboratory Medicine hematological and biochemical diagnostic tests.

    PubMed

    Dorizzi, R M; Maconi, M; Giavarina, D; Loza, G; Aman, M; Moreira, J; Bisoffi, Z; Gennuso, C

    2009-10-01

    The adoption of Evidence Based Laboratory Medicine (EBLM) has been hampered until today by the lack of effective tools. The SIMeL EBLM e-Thesaurus (on-line Repertoire of the diagnostic effectiveness of the laboratory, radiology and cardiology test) provides a useful support to clinical laboratory professionals and to clinicians for the interpretation of the diagnostic tests. The e-Thesaurus is an application developed using Microsoft Active Server Pages technology and carried out with Web Server Microsoft Internet Information Server and is available at the SIMeL website using a browser running JavaScript scripts (Internet Explorer is recommended). It contains a database (in Italian, English and Spanish) of the sensitivity and specificity (including the 95% confidence interval), the positive and negative likelihood ratios, the Diagnostic Odds Ratio and the Number Needed to Diagnose of more than 2000 diagnostic (most laboratory but also cardiology and radiology) tests. The e-Thesaurus improves the previous SIMeL paper and CD Thesaurus; its main features are a three languages search and a continuous and an easy updating capability.

  17. Laboratories | NREL

    Science.gov Websites

    | Z A Accelerated Exposure Testing Laboratory Advanced Optical Materials Laboratory Advanced Thermal Laboratory Structural Testing Laboratory Surface Analysis Laboratory Systems Performance Laboratory T Thermal Storage Materials Laboratory Thermal Storage Process and Components Laboratory Thin-Film Deposition

  18. Urinary lithogenesis risk tests: comparison of a commercial kit and a laboratory prototype test.

    PubMed

    Grases, Félix; Costa-Bauzá, Antonia; Prieto, Rafel M; Arrabal, Miguel; De Haro, Tomás; Lancina, Juan A; Barbuzano, Carmen; Colom, Sergi; Riera, Joaquín; Perelló, Joan; Isern, Bernat; Sanchis, Pilar; Conte, Antonio; Barragan, Fernando; Gomila, Isabel

    2011-11-01

    Renal stone formation is a multifactorial process depending in part on urine composition. Other parameters relate to structural or pathological features of the kidney. To date, routine laboratory estimation of urolithiasis risk has been based on determination of urinary composition. This process requires collection of at least two 24 h urine samples, which is tedious for patients. The most important feature of urinary lithogenic risk is the balance between various urinary parameters, although unknown factors may be involved. The objective of this study was to compare data obtained using a commercial kit with those of a laboratory prototype, using a multicentre approach, to validate the utility of these methods in routine clinical practice. A simple new commercial test (NefroPlus®; Sarstedt AG & Co., Nümbrecht, Germany) evaluating the capacity of urine to crystallize calcium salts, and thus permitting detection of patients at risk for stone development, was compared with a prototype test previously described by this group. Urine of 64 volunteers produced during the night was used in these comparisons. The commercial test was also used to evaluate urine samples of 83 subjects in one of three hospitals. Both methods were essentially in complete agreement (98%) with respect to test results. The multicentre data were: sensitivity 94.7%; specificity 76.9%; positive predictive value (lithogenic urine) 90.0%; negative predictive value (non-lithogenic urine) 87.0%; test efficacy 89.2%. The new commercial NefroPlus test offers fast and cheap evaluation of the overall risk of development of urinary calcium-containing calculi.

  19. Estrogen and progesterone receptor testing in breast carcinoma: concordance of results between local and reference laboratories in Brazil.

    PubMed

    Wludarski, Sheila Cristina Lordelo; Lopes, Lisandro Ferreira; Duarte, Ivison Xavier; Carvalho, Filomena Marino; Weiss, Lawrence; Bacchi, Carlos Eduardo

    2011-01-01

    Breast cancer accounts for approximately one quarter of all cancers in females. Estrogen and progesterone receptor testing has become an essential part of the clinical evaluation of breast carcinoma patients, and accurate results are critical in identifying patients who may benefit from hormone therapy. The present study had the aim of investigating the concordance of the results from hormone receptor tests between a reference laboratory and local (or community) laboratories in Brazil. Retrospective study at a reference pathology laboratory. The concordance in the results from hormone receptor tests between a reference laboratory and 146 local laboratories in Brazil was compared in relation to 500 invasive breast carcinoma cases, using immunohistochemistry. There was concordance in 89.4% (447/500 cases) and 85.0% (425/500 cases) of the results from estrogen (κ = 0.744, P < 0.001) and progesterone (κ = 0.688, P < 0.001) receptor tests, respectively, between local and reference laboratories. This was similar to findings in other countries. The false negative rates from estrogen and progesterone receptor tests in local laboratories were 8.7% and 14.4%, respectively. The false positive rates from estrogen and progesterone receptor tests in local laboratories were 15.5% and 16.0%, respectively. Technical and result interpretation issues may explain most of the discordances in hormone receptor testing in local laboratories. Validation of estrogen and progesterone receptor tests at local laboratories, with rigorous quality control measures, is strongly recommended in order to avoid erroneous treatment of breast cancer patients.

  20. Mounted Smartphones as Measurement and Control Platforms for Motor-Based Laboratory Test-Beds.

    PubMed

    Frank, Jared A; Brill, Anthony; Kapila, Vikram

    2016-08-20

    Laboratory education in science and engineering often entails the use of test-beds equipped with costly peripherals for sensing, acquisition, storage, processing, and control of physical behavior. However, costly peripherals are no longer necessary to obtain precise measurements and achieve stable feedback control of test-beds. With smartphones performing diverse sensing and processing tasks, this study examines the feasibility of mounting smartphones directly to test-beds to exploit their embedded hardware and software in the measurement and control of the test-beds. This approach is a first step towards replacing laboratory-grade peripherals with more compact and affordable smartphone-based platforms, whose interactive user interfaces can engender wider participation and engagement from learners. Demonstrative cases are presented in which the sensing, computation, control, and user interaction with three motor-based test-beds are handled by a mounted smartphone. Results of experiments and simulations are used to validate the feasibility of mounted smartphones as measurement and feedback control platforms for motor-based laboratory test-beds, report the measurement precision and closed-loop performance achieved with such platforms, and address challenges in the development of platforms to maintain system stability.

  1. Comparison of basic laboratory test results with more sophisticated laboratory and in-situ tests methods on soils in southeastern Wisconsin : final report, March 21, 2009.

    DOT National Transportation Integrated Search

    2009-03-21

    This study investigates all of the generated soils data in an attempt to use the more 'routine' laboratory tests to determine geotechnical design parameters (such as phiangle, cohesion, wet unit weight, unconfined compression, consolidation character...

  2. Testing the performance of microbiological safety cabinets used in microbiology laboratories in South Korea.

    PubMed

    Hwang, S H; Yi, T W; Cho, K H; Lee, I M; Yoon, C S

    2011-09-01

    To test a performance of the microbiological safety cabinets (MSCs) according to the type of MSCs in microbial laboratories. Tests were carried out to assess the performance of 31 MSCs in 14 different facilities, including six different biological test laboratories in six hospitals and eight different laboratories in three universities. The following tests were performed on the MSCs: the downflow test, intake velocity test, high-efficiency particulate air filter leak test and the airflow smoke pattern test. These performance tests were carried out in accordance with the standard procedures. Only 23% of Class II A1 (8), A2 (19) and unknown MSCs (4) passed these performance tests. The main reasons for the failure of MSCs were inappropriate intake velocity (65%), leakage in the HEPA filter sealing (50%), unbalanced airflow smoke pattern in the cabinets (39%) and inappropriate downflow (27%). This study showed that routine checks of MSCs are important to detect and strengthen the weak spots that frequently develop, as observed during the evaluation of the MSCs of various institutions. Routine evaluation and maintenance of MSCs are critical for optimizing performance. © 2011 The Authors. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.

  3. [Revolution of the health care delivery system and its impacts on laboratory testing in the United States].

    PubMed

    Takemura, Y; Ishibashi, M

    2000-02-01

    Failure to slow the exponential growth of total health care expenditures in the United States through the government policies resulted in a rapid and progressive penetration of managed care organizations(MCOs) in the early 1990s. Diagnostic testing is viewed as a "commodity" rather than a medical service under the managed care environment. Traditional hospital-based laboratories are placed in a downward spiral with the advent of managed care era. A massive reduction of in-house testing resulted from shorter lengths of patients' hospital stay and a marked decrease in admission under the dominance of managed care urges them to develop strategies for restoring tests deprived by the managed care-associated new businesses: consolidation and networking, participation in the outreach-testing market, and point-of-care/satellite laboratory testing in non-traditional, ambulatory settings are major strategies for survival of hospital laboratories. A number of physicians' office laboratories(POLs) have been closed owing to regulatory restrictions imposed by the Clinical Laboratory Improvement Amendments of 1988(CLIA '88), and to the expanded penetration of MCOs which limit reimbursement to a very few in-house procedures. It seems likely that POLs and hospital laboratories continue to reduce test volumes, while commercial reference laboratories(CRLs) gain more tests through contracting with MCOs. In the current stream of managed care dominance in the United States, clinical laboratories are changing their basic operation focus and mission in response to the aggressively changing landscape. Traditional laboratories which are unwilling to adapt themselves to the new environment will not survive in this country.

  4. Proficiency Testing Activities of Frequency Calibration Laboratories in Taiwan, 2009

    DTIC Science & Technology

    2009-11-01

    cht.com.tw Abstract In order to meet the requirements of ISO 17025 and the demand of TAF (Taiwan Accreditation Foundation) for calibration inter... IEC 17025 General requirements for the competence of testing and calibration laboratories. The proficiency testing results are then important...on-site evaluation, an assessment team is organized to examine the technical competence of the labs and their compliance with the requirements of ISO

  5. Testing painted wood : past practices at the Forest Products Laboratory and recommendations for future research

    Treesearch

    R. Sam Williams

    2009-01-01

    A brief history of paint research at the Forest Products Laboratory (FPL) in Madison, Wisconsin, sets the stage for a discussion of testing paint on wood and wood products. Tests include laboratory and outdoor tests, and I discuss them in terms of several degradation mechanisms (loss of gloss and fading, mildew growth, extractives bleed, and cracking, flaking, and...

  6. 9 CFR 54.11 - Approval of laboratories to run official scrapie tests and official genotype tests.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false Approval of laboratories to run official scrapie tests and official genotype tests. 54.11 Section 54.11 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE COOPERATIVE CONTROL AND ERADICATION OF LIVESTOCK OR POULTRY DISEASES CONTROL OF...

  7. 9 CFR 55.8 - Official CWD tests and approval of laboratories to conduct official CWD tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Official CWD tests and approval of laboratories to conduct official CWD tests. 55.8 Section 55.8 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE COOPERATIVE CONTROL AND ERADICATION OF LIVESTOCK OR POULTRY DISEASES CONTROL OF CHRONIC...

  8. 9 CFR 55.8 - Official CWD tests and approval of laboratories to conduct official CWD tests.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false Official CWD tests and approval of laboratories to conduct official CWD tests. 55.8 Section 55.8 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE COOPERATIVE CONTROL AND ERADICATION OF LIVESTOCK OR POULTRY DISEASES CONTROL OF CHRONIC...

  9. 9 CFR 55.8 - Official CWD tests and approval of laboratories to conduct official CWD tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false Official CWD tests and approval of laboratories to conduct official CWD tests. 55.8 Section 55.8 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE COOPERATIVE CONTROL AND ERADICATION OF LIVESTOCK OR POULTRY DISEASES CONTROL OF CHRONIC...

  10. 9 CFR 55.8 - Official CWD tests and approval of laboratories to conduct official CWD tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Official CWD tests and approval of laboratories to conduct official CWD tests. 55.8 Section 55.8 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE COOPERATIVE CONTROL AND ERADICATION OF LIVESTOCK OR POULTRY DISEASES CONTROL OF CHRONIC...

  11. 9 CFR 54.11 - Approval of laboratories to run official scrapie tests and official genotype tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false Approval of laboratories to run official scrapie tests and official genotype tests. 54.11 Section 54.11 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE COOPERATIVE CONTROL AND ERADICATION OF LIVESTOCK OR POULTRY DISEASES CONTROL OF...

  12. 9 CFR 55.8 - Official CWD tests and approval of laboratories to conduct official CWD tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Official CWD tests and approval of laboratories to conduct official CWD tests. 55.8 Section 55.8 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE COOPERATIVE CONTROL AND ERADICATION OF LIVESTOCK OR POULTRY DISEASES CONTROL OF CHRONIC...

  13. 9 CFR 54.11 - Approval of laboratories to run official scrapie tests and official genotype tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Approval of laboratories to run official scrapie tests and official genotype tests. 54.11 Section 54.11 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE COOPERATIVE CONTROL AND ERADICATION OF LIVESTOCK OR POULTRY DISEASES CONTROL OF...

  14. 9 CFR 54.11 - Approval of laboratories to run official scrapie tests and official genotype tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Approval of laboratories to run official scrapie tests and official genotype tests. 54.11 Section 54.11 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE COOPERATIVE CONTROL AND ERADICATION OF LIVESTOCK OR POULTRY DISEASES CONTROL OF...

  15. Collaborative Testing in Practical Laboratories: An Effective Teaching-Learning Method in Histology.

    PubMed

    Guo, Yuping; Li, Enzhong

    2016-01-01

    This article presents an experimental teaching and learning program used in histology with first-year students in the second term in the Faculty of Biology at Huanghuai University, China. Eighty-six students were divided randomly into two groups (n=43 per group). Tests were conducted at the end of each practical laboratory (10 laboratories in total) in which collaborative testing was used in the experimental group and traditional testing in the control group. To assess achievement, a final examination in histology was carried out at the end of the course. To determine students' attitude to the teaching styles, a questionnaire survey was conducted at the end of the term. Results showed that students preferred the collaborative testing format. In the experimental group, students' scores were significantly higher than those of students in the control group in final examinations. These findings indicate that collaborative testing enhances student learning and understanding of the material taught, and suggest that collaborative testing is an effective teaching-learning method in histology.

  16. Validation of laboratory-scale recycling test method of paper PSA label products

    Treesearch

    Carl Houtman; Karen Scallon; Richard Oldack

    2008-01-01

    Starting with test methods and a specification developed by the U.S. Postal Service (USPS) Environmentally Benign Pressure Sensitive Adhesive Postage Stamp Program, a laboratory-scale test method and a specification were developed and validated for pressure-sensitive adhesive labels, By comparing results from this new test method and pilot-scale tests, which have been...

  17. Real-time laboratory exercises to test contingency plans for classical swine fever: experiences from two national laboratories.

    PubMed

    Koenen, F; Uttenthal, A; Meindl-Böhmer, A

    2007-12-01

    In order to adequately and efficiently handle outbreaks of contagious diseases such as classical swine fever (CSF), foot and mouth disease or highly pathogenic avian influenza, competent authorities and the laboratories involved have to be well prepared and must be in possession of functioning contingency plans. These plans should ensure that in the event of an outbreak access to facilities, equipment, resources, trained personnel, and all other facilities needed for the rapid and efficient eradication of the outbreak is guaranteed, and that the procedures to follow are well rehearsed. It is essential that these plans are established during 'peace-time' and are reviewed regularly. This paper provides suggestions on how to perform laboratory exercises to test preparedness and describes the experiences of two national reference laboratories for CSF. The major lesson learnt was the importance of a well-documented laboratory contingency plan. The major pitfalls encountered were shortage of space, difficulties in guaranteeing biosecurity and sufficient supplies of sterile equipment and consumables. The need for a standardised laboratory information management system, that is used by all those involved in order to reduce the administrative load, is also discussed.

  18. From laboratory corrosion tests to a corrosion lifetime for wood fasteners : progress and challenges

    Treesearch

    Samuel L. Zelinka; Dominique Derome; Samuel V. Glass

    2010-01-01

    Determining a “corrosion-lifetime” for fasteners embedded in wood treated with recently adopted preservative systems depends upon successfully relating results of laboratory tests to in-service conditions. In contrast to laboratory tests where metal is embedded in wood at constant temperature and moisture content, the in-service temperature and moisture content of wood...

  19. SPHINX Satellite Testing in the Electric Propulsion Laboratory

    NASA Image and Video Library

    1973-12-21

    Researchers examine the Space Plasma-High Voltage Interaction Experiment (SPHINX) satellite in the Electric Propulsion Laboratory at the National Aeronautics and Space Administration (NASA) Lewis Research Center. Lewis’ Spacecraft Technology Division designed SPHINX to study the electrical interaction of its experimental surfaces with space plasma. They sought to determine if higher orbits would improve the transmission quality of communications satellites. Robert Lovell, the Project Manager, oversaw vibrational and plasma simulation testing of the satellite in the Electric Propulsion Laboratory, seen here. SPHINX was an add-on payload for the first Titan/Centaur proof launch in early 1974. Lewis successfully managed the Centaur Program since 1962, but this would be the first Centaur launch with a Titan booster. Since the proof test did not have a scheduled payload, the Lewis-designed SPHINX received a free ride. The February 11, 1974 launch, however, proved to be one of the Launch Vehicle Division’s lowest days. Twelve minutes after the vehicle departed the launch pad, the booster and Centaur separated as designed, but Centaur’s two RL-10 engines failed to ignite. The launch pad safety officer destroyed the vehicle, and SPHINX never made it into orbit. Overall Centaur has an excellent success rate, but the failed SPHINX launch attempt caused deep disappointment across the center.

  20. 7 CFR 91.37 - Standard hourly fee rate for laboratory testing, analysis, and other services.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Standard hourly fee rate for laboratory testing, analysis, and other services. 91.37 Section 91.37 Agriculture Regulations of the Department of Agriculture... AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and...

  1. Announcement: Guidance for U.S. Laboratory Testing for Zika Virus Infection: Implications for Health Care Providers.

    PubMed

    2016-11-25

    CDC has released updated guidance online for U.S. laboratory testing for Zika virus infection. The guidance is available at https://www.cdc.gov/zika/laboratories/lab-guidance.html. Frequently asked questions are addressed at https://www.cdc.gov/zika/laboratories/lab-guidance-faq.html. This guidance updates recommendations for testing of specimens by U.S. laboratories for possible Zika virus infection. Major updates to the guidance with clinical implications for health care providers include the following.

  2. Tried and True: Tested Ideas for Teaching and Learning from the Regional Educational Laboratories.

    ERIC Educational Resources Information Center

    Levinson, Luna; Stonehill, Robert

    This collection of 16 tested ideas for improving teaching and learning evolved from the work of the 1995 Proven Laboratory Practices Task Force charged with identifying and collecting the best and most useful work from the Regional Educational Laboratories. The Regional Educational Laboratory program is the largest research and development…

  3. Laboratory Testing of Waste Isolation Pilot Plant Surrogate Waste Materials

    NASA Astrophysics Data System (ADS)

    Broome, S.; Bronowski, D.; Pfeifle, T.; Herrick, C. G.

    2011-12-01

    The Waste Isolation Pilot Plant (WIPP) is a U.S. Department of Energy geological repository for the permanent disposal of defense-related transuranic (TRU) waste. The waste is emplaced in rooms excavated in the bedded Salado salt formation at a depth of 655 m below the ground surface. After emplacement of the waste, the repository will be sealed and decommissioned. WIPP Performance Assessment modeling of the underground material response requires a full and accurate understanding of coupled mechanical, hydrological, and geochemical processes and how they evolve with time. This study was part of a broader test program focused on room closure, specifically the compaction behavior of waste and the constitutive relations to model this behavior. The goal of this study was to develop an improved waste constitutive model. The model parameters are developed based on a well designed set of test data. The constitutive model will then be used to realistically model evolution of the underground and to better understand the impacts on repository performance. The present study results are focused on laboratory testing of surrogate waste materials. The surrogate wastes correspond to a conservative estimate of the degraded containers and TRU waste materials after the 10,000 year regulatory period. Testing consists of hydrostatic, uniaxial, and triaxial tests performed on surrogate waste recipes that were previously developed by Hansen et al. (1997). These recipes can be divided into materials that simulate 50% and 100% degraded waste by weight. The percent degradation indicates the anticipated amount of iron corrosion, as well as the decomposition of cellulosics, plastics, and rubbers. Axial, lateral, and volumetric strain and axial and lateral stress measurements were made. Two unique testing techniques were developed during the course of the experimental program. The first involves the use of dilatometry to measure sample volumetric strain under a hydrostatic condition. Bulk

  4. Launching a Laboratory Testing Process Quality Improvement Toolkit: From the Shared Networks of Colorado Ambulatory Practices and Partners (SNOCAP).

    PubMed

    Fernald, Douglas; Hamer, Mika; James, Kathy; Tutt, Brandon; West, David

    2015-01-01

    Family medicine and internal medicine physicians order diagnostic laboratory tests for nearly one-third of patient encounters in an average week, yet among medical errors in primary care, an estimated 15% to 54% are attributed to laboratory testing processes. From a practice improvement perspective, we (1) describe the need for laboratory testing process quality improvements from the perspective of primary care practices, and (2) describe the approaches and resources needed to implement laboratory testing process quality improvements in practice. We applied practice observations, process mapping, and interviews with primary care practices in the Shared Networks of Colorado Ambulatory Practices and Partners (SNOCAP)-affiliated practice-based research networks that field-tested in 2013 a laboratory testing process improvement toolkit. From the data collected in each of the 22 participating practices, common testing quality issues included, but were not limited to, 3 main testing process steps: laboratory test preparation, test tracking, and patient notification. Three overarching qualitative themes emerged: practices readily acknowledge multiple laboratory testing process problems; practices know that they need help addressing the issues; and practices face challenges with finding patient-centered solutions compatible with practice priorities and available resources. While practices were able to get started with guidance and a toolkit to improve laboratory testing processes, most did not seem able to achieve their quality improvement aims unassisted. Providing specific guidance tools with practice facilitation or other rapid-cycle quality improvement support may be an effective approach to improve common laboratory testing issues in primary care. © Copyright 2015 by the American Board of Family Medicine.

  5. Laboratory and field tests of the Sutron RLR-0003-1 water level sensor

    USGS Publications Warehouse

    Fulford, Janice M.; Bryars, R. Scott

    2015-01-01

    Three Sutron RLR-0003-1 water level sensors were tested in laboratory conditions to evaluate the accuracy of the sensor over the manufacturer’s specified operating temperature and distance-to-water ranges. The sensor was also tested for compliance to SDI-12 communication protocol and in field conditions at a U.S. Geological Survey (USGS) streamgaging site. Laboratory results were compared to the manufacturer’s accuracy specification for water level and to the USGS Office of Surface Water (OSW) policy requirement that water level sensors have a measurement uncertainty of no more than 0.01 foot or 0.20 percent of the indicated reading. Except for one sensor, the differences for the temperature testing were within 0.05 foot and the average measurements for the sensors were within the manufacturer’s accuracy specification. Two of the three sensors were within the manufacturer’s specified accuracy and met the USGS accuracy requirements for the laboratory distance to water testing. Three units passed a basic SDI-12 communication compliance test. Water level measurements made by the Sutron RLR-0003-1 during field testing agreed well with those made by the bubbler system and a Design Analysis Associates (DAA) H3613 radar, and they met the USGS accuracy requirements when compared to the wire-weight gage readings.

  6. Diagnostic performances of clinical laboratory tests using Triton X-100 to reduce the biohazard associated with routine testing of Ebola virus-infected patients.

    PubMed

    Tempestilli, Massimo; Pucci, Luigia; Notari, Stefania; Di Caro, Antonino; Castilletti, Concetta; Rivelli, Maria Rosaria; Agrati, Chiara; Pucillo, Leopoldo Paolo

    2015-11-01

    Ebola virus, an enveloped virus, is the cause of the largest and most complex Ebola virus disease (EVD) outbreak in West Africa. Blood or body fluids of an infected person may represent a biohazard to laboratory workers. Laboratory tests of virus containing specimens should be conducted in referral centres at biosafety level 4, but based on the severity of clinical symptoms, basic laboratories might be required to execute urgent tests for patients suspected of EVD. The aim of this work was to compare the analytical performances of laboratory tests when Triton X-100, a chemical agent able to inactivate other enveloped viruses, was added to specimens. Results of clinical chemistry, coagulation and haematology parameters on samples before and after the addition of 0.1% (final concentration) of Triton X-100 and 1 h of incubation at room temperature were compared. Overall, results showed very good agreement by all statistical analyses. Triton X-100 at 0.1% did not significantly affect the results for the majority of the analytes tested. Triton X-100 at 0.1% can be used to reduce the biohazard in performing laboratory tests on samples from patients with EVD without affecting clinical decisions.

  7. Description and Laboratory Tests of a Roots Type Aircraft Engine Supercharger

    NASA Technical Reports Server (NTRS)

    Ware, Marsden

    1926-01-01

    This report describes a roots type aircraft engine supercharger and presents the results of some tests made with it at the Langley Field Laboratories of the National Advisory Committee for Aeronautics. The supercharger used in these tests was constructed largely of aluminum, weighed 88 pounds and was arranged to be operated from the rear of a standard aircraft engine at a speed of 1 1/2 engine crankshaft speed. The rotors of the supercharger were cycloidal in form and were 11 inches long and 9 1/2 inches in diameter. The displacement of the supercharger was 0.51 cubic feet of air per revolution of the rotors. The supercharger was tested in the laboratory, independently and in combination with a Liberty-12 aircraft engine, under simulated altitude pressure conditions in order to obtain information on its operation and performance. From these tests it seems evident that the Roots blower compares favorably with other compressor types used as aircraft engine superchargers and that it has several features that make it particularly attractive for such use.

  8. Digital Audio Radio Broadcast Systems Laboratory Testing Nearly Complete

    NASA Technical Reports Server (NTRS)

    2005-01-01

    Radio history continues to be made at the NASA Lewis Research Center with the completion of phase one of the digital audio radio (DAR) testing conducted by the Consumer Electronics Group of the Electronic Industries Association. This satellite, satellite/terrestrial, and terrestrial digital technology will open up new audio broadcasting opportunities both domestically and worldwide. It will significantly improve the current quality of amplitude-modulated/frequency-modulated (AM/FM) radio with a new digitally modulated radio signal and will introduce true compact-disc-quality (CD-quality) sound for the first time. Lewis is hosting the laboratory testing of seven proposed digital audio radio systems and modes. Two of the proposed systems operate in two modes each, making a total of nine systems being tested. The nine systems are divided into the following types of transmission: in-band on-channel (IBOC), in-band adjacent-channel (IBAC), and new bands. The laboratory testing was conducted by the Consumer Electronics Group of the Electronic Industries Association. Subjective assessments of the audio recordings for each of the nine systems was conducted by the Communications Research Center in Ottawa, Canada, under contract to the Electronic Industries Association. The Communications Research Center has the only CCIR-qualified (Consultative Committee for International Radio) audio testing facility in North America. The main goals of the U.S. testing process are to (1) provide technical data to the Federal Communication Commission (FCC) so that it can establish a standard for digital audio receivers and transmitters and (2) provide the receiver and transmitter industries with the proper standards upon which to build their equipment. In addition, the data will be forwarded to the International Telecommunications Union to help in the establishment of international standards for digital audio receivers and transmitters, thus allowing U.S. manufacturers to compete in the

  9. Proficiency Tests for Environmental Radioactivity Measurement Organized by an Accredited Laboratory

    NASA Astrophysics Data System (ADS)

    Aubert, Cédric; Osmond, Mélanie

    2008-08-01

    For 40 years, STEME (Environmental Sample Processing and Metrology Department) organized international proficiency testing (PT) exercises formerly for WHO (World Health Organization) and EC (European Community) and currently for ASN (French Nuclear Safety Authority). Five PT exercises are organized each year for the measurement of radionuclides (alpha, beta and gamma) in different matrixes (water, soil, biological and air samples) at environmental levels. ASN can deliver a French ministerial agreement to participate on environmental radioactivity measurements French network for laboratories asking it [1]. Since 2006, November, STEME is the first French entity obtaining a COFRAC (French Committee of Accreditation) accreditation as "Interlaboratory Comparisons" for the organization of proficiency tests for environmental radioactivity measurement according to standard International Standard Organization (ISO) 17025 and guide ISO 43-1. STEME has in charge to find, as far as possible, real sample or to create, by radionuclide adding, an adapted sample. STEME realizes the sampling, the samples preparation and the dispatching. STEME is also accredited according to Standard 17025 for radioactivity measurements in environmental samples and determines homogeneity, stability and reference values. After the reception of participating laboratories results, STEME executes statistical treatments in order to verify the normal distribution, to eliminate outliers and to evaluate laboratories performance. Laboratories participate with several objectives, to obtain French agreement, to prove the quality of their analytical performance in regards to standard 17025 or to validate new methods or latest developments. For 2 years, in addition to usual PT exercises, new PT about alpha or beta measurement in air filters, radioactive iodine in carbon cartridges or measurement of environmental dosimeters are organized. These PT exercises help laboratories to improve radioactive measurements

  10. Proficiency Tests for Environmental Radioactivity Measurement Organized by an Accredited Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aubert, Cedric; Osmond, Melanie

    2008-08-14

    For 40 years, STEME (Environmental Sample Processing and Metrology Department) organized international proficiency testing (PT) exercises formerly for WHO (World Health Organization) and EC (European Community) and currently for ASN (French Nuclear Safety Authority). Five PT exercises are organized each year for the measurement of radionuclides (alpha, beta and gamma) in different matrixes (water, soil, biological and air samples) at environmental levels. ASN can deliver a French ministerial agreement to participate on environmental radioactivity measurements French network for laboratories asking it. Since 2006, November, STEME is the first French entity obtaining a COFRAC (French Committee of Accreditation) accreditation as 'Interlaboratorymore » Comparisons' for the organization of proficiency tests for environmental radioactivity measurement according to standard International Standard Organization (ISO) 17025 and guide ISO 43-1. STEME has in charge to find, as far as possible, real sample or to create, by radionuclide adding, an adapted sample. STEME realizes the sampling, the samples preparation and the dispatching. STEME is also accredited according to Standard 17025 for radioactivity measurements in environmental samples and determines homogeneity, stability and reference values. After the reception of participating laboratories results, STEME executes statistical treatments in order to verify the normal distribution, to eliminate outliers and to evaluate laboratories performance.Laboratories participate with several objectives, to obtain French agreement, to prove the quality of their analytical performance in regards to standard 17025 or to validate new methods or latest developments. For 2 years, in addition to usual PT exercises, new PT about alpha or beta measurement in air filters, radioactive iodine in carbon cartridges or measurement of environmental dosimeters are organized. These PT exercises help laboratories to improve radioactive measurements

  11. State 'laboratories' test health care reform solutions.

    PubMed

    Elliott, B A

    1993-02-01

    Widely recognized by the states as a pressing policy issue, health care reform appears to have moved up on the national policy agenda as well. President Clinton has promised to address the issue during his first 100 days in office. Previously, however, the federal government has been deadlocked on health care reform, leaving the states to become the laboratories for developing and testing proposed solutions to our health care crisis. By passing MinnesotaCare in last year's legislative session, Minnesota joined the growing number of states attempting to provide access to affordable, quality health care to their citizens.

  12. Changing resident test ordering behavior: a multilevel intervention to decrease laboratory utilization at an academic medical center.

    PubMed

    Vidyarthi, Arpana R; Hamill, Timothy; Green, Adrienne L; Rosenbluth, Glenn; Baron, Robert B

    2015-01-01

    Hospital laboratory test volume is increasing, and overutilization contributes to errors and costs. Efforts to reduce laboratory utilization have targeted aspects of ordering behavior, but few have utilized a multilevel collaborative approach. The study team partnered with residents to reduce unnecessary laboratory tests and associated costs through multilevel interventions across the academic medical center. The study team selected laboratory tests for intervention based on cost, volume, and ordering frequency (complete blood count [CBC] and CBC with differential, common electrolytes, blood enzymes, and liver function tests). Interventions were designed collaboratively with residents and targeted components of ordering behavior, including system changes, teaching, social marketing, academic detailing, financial incentives, and audit/feedback. Laboratory ordering was reduced by 8% cumulatively over 3 years, saving $2 019 000. By involving residents at every stage of the intervention and targeting multiple levels simultaneously, laboratory utilization was reduced and cost savings were sustained over 3 years. © 2014 by the American College of Medical Quality.

  13. How Do Experienced Physicians Access and Evaluate Laboratory Test Results for the Chronic Patient? A Qualitative Analysis.

    PubMed

    Torsvik, Torbjørn; Lillebo, Børge; Hertzum, Morten

    2018-04-01

     Electronic health records may present laboratory test results in a variety of ways. Little is known about how the usefulness of different visualizations of laboratory test results is influenced by the complex and varied process of clinical decision making.  The purpose of this study was to investigate how clinicians access and utilize laboratory test results when caring for patients with chronic illness.  We interviewed 10 attending physicians about how they access and assess laboratory tests when following up patients with chronic illness. The interviews were audio-recorded, transcribed verbatim, and analyzed qualitatively.  Informants preferred different visualizations of laboratory test results, depending on what aspects of the data they were interested in. As chronic patients may have laboratory test results that are permanently outside standardized reference ranges, informants would often look for significant change, rather than exact values. What constituted significant change depended on contextual information (e.g., the results of other investigations, intercurrent diseases, and medical interventions) spread across multiple locations in the electronic health record. For chronic patients, the temporal relations between data could often be of special interest. Informants struggled with finding and synthesizing fragmented information into meaningful overviews.  The presentation of laboratory test results should account for the large variety of associated contextual information needed for clinical comprehension. Future research is needed to improve the integration of the different parts of the electronic health record. Schattauer GmbH Stuttgart.

  14. Thermocouple Calibration and Accuracy in a Materials Testing Laboratory

    NASA Technical Reports Server (NTRS)

    Lerch, B. A.; Nathal, M. V.; Keller, D. J.

    2002-01-01

    A consolidation of information has been provided that can be used to define procedures for enhancing and maintaining accuracy in temperature measurements in materials testing laboratories. These studies were restricted to type R and K thermocouples (TCs) tested in air. Thermocouple accuracies, as influenced by calibration methods, thermocouple stability, and manufacturer's tolerances were all quantified in terms of statistical confidence intervals. By calibrating specific TCs the benefits in accuracy can be as great as 6 C or 5X better compared to relying on manufacturer's tolerances. The results emphasize strict reliance on the defined testing protocol and on the need to establish recalibration frequencies in order to maintain these levels of accuracy.

  15. Distributed Acoustic Sensing (DAS) for Periodic Hydraulic Tests: Laboratory Data

    DOE Data Explorer

    Coleman, Thomas

    2015-02-27

    These data were collected in the laboratory located at California State University Long Beach. They consist of DAS data collected from a fiber optic cable placed in a tank of water, subjected to oscillating head. These tests are described in the article linked below.

  16. Analysis of laboratory testing results collected in an enhanced chlamydia surveillance system in Australia, 2008-2010.

    PubMed

    Dimech, Wayne; Lim, Megan S C; Van Gemert, Caroline; Guy, Rebecca; Boyle, Douglas; Donovan, Basil; Hellard, Margaret

    2014-06-12

    Chlamydial infection is the most common notifiable disease in Australia, Europe and the US. Australian notifications of chlamydia rose four-fold from 20,274 cases in 2002 to 80,846 cases in 2011; the majority of cases were among young people aged less than 29 years. Along with test positivity rates, an understanding of the number of tests performed and the demographics of individuals being tested are key epidemiological indicators. The ACCESS Laboratory Network was established in 2008 to address this issue. The ACCESS Laboratory Network collected chlamydia testing data from 15 laboratories around Australia over a three-year period using data extraction software. All chlamydia testing data from participating laboratories were extracted from the laboratory information system; patient identifiers converted to a unique, non-reversible code and de-identified data sent to a single database. Analysis of data by anatomical site included all specimens, but in age and sex specific analysis, only one testing episode was counted. From 2008 to 2010 a total of 628,295 chlamydia tests were referred to the 15 laboratories. Of the 592,626 individual episodes presenting for testing, 70% were from female and 30% from male patients. In female patients, chlamydia positivity rate was 6.4% overall; the highest rate in 14 year olds (14.3%). In male patients, the chlamydia positivity rate was 9.4% overall; the highest in 19 year olds (16.5%). The most common sample type was urine (57%). In 3.2% of testing episodes, multiple anatomical sites were sampled. Urethral swabs gave the highest positivity rate for all anatomical sites in both female (7.7%) and male patients (14%), followed by urine (7.6% and 9.4%, respectively) and eye (6.3% and 7.9%, respectively). The ACCESS Laboratory Network data are unique in both number and scope and are representative of chlamydia testing in both general practice and high-risk clinics. The findings from these data highlight much lower levels of testing in

  17. Artificial Neural Network Approach in Laboratory Test Reporting:  Learning Algorithms.

    PubMed

    Demirci, Ferhat; Akan, Pinar; Kume, Tuncay; Sisman, Ali Riza; Erbayraktar, Zubeyde; Sevinc, Suleyman

    2016-08-01

    In the field of laboratory medicine, minimizing errors and establishing standardization is only possible by predefined processes. The aim of this study was to build an experimental decision algorithm model open to improvement that would efficiently and rapidly evaluate the results of biochemical tests with critical values by evaluating multiple factors concurrently. The experimental model was built by Weka software (Weka, Waikato, New Zealand) based on the artificial neural network method. Data were received from Dokuz Eylül University Central Laboratory. "Training sets" were developed for our experimental model to teach the evaluation criteria. After training the system, "test sets" developed for different conditions were used to statistically assess the validity of the model. After developing the decision algorithm with three iterations of training, no result was verified that was refused by the laboratory specialist. The sensitivity of the model was 91% and specificity was 100%. The estimated κ score was 0.950. This is the first study based on an artificial neural network to build an experimental assessment and decision algorithm model. By integrating our trained algorithm model into a laboratory information system, it may be possible to reduce employees' workload without compromising patient safety. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. The Computerized Laboratory Notebook concept for genetic toxicology experimentation and testing.

    PubMed

    Strauss, G H; Stanford, W L; Berkowitz, S J

    1989-03-01

    We describe a microcomputer system utilizing the Computerized Laboratory Notebook (CLN) concept developed in our laboratory for the purpose of automating the Battery of Leukocyte Tests (BLT). The BLT was designed to evaluate blood specimens for toxic, immunotoxic, and genotoxic effects after in vivo exposure to putative mutagens. A system was developed with the advantages of low cost, limited spatial requirements, ease of use for personnel inexperienced with computers, and applicability to specific testing yet flexibility for experimentation. This system eliminates cumbersome record keeping and repetitive analysis inherent in genetic toxicology bioassays. Statistical analysis of the vast quantity of data produced by the BLT would not be feasible without a central database. Our central database is maintained by an integrated package which we have adapted to develop the CLN. The clonal assay of lymphocyte mutagenesis (CALM) section of the CLN is demonstrated. PC-Slaves expand the microcomputer to multiple workstations so that our computerized notebook can be used next to a hood while other work is done in an office and instrument room simultaneously. Communication with peripheral instruments is an indispensable part of many laboratory operations, and we present a representative program, written to acquire and analyze CALM data, for communicating with both a liquid scintillation counter and an ELISA plate reader. In conclusion we discuss how our computer system could easily be adapted to the needs of other laboratories.

  19. 21 CFR 312.160 - Drugs for investigational use in laboratory research animals or in vitro tests.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... research animals or in vitro tests. 312.160 Section 312.160 Food and Drugs FOOD AND DRUG ADMINISTRATION... Drugs for Investigational Use in Laboratory Research Animals or In Vitro Tests § 312.160 Drugs for investigational use in laboratory research animals or in vitro tests. (a) Authorization to ship. (1)(i) A person...

  20. 21 CFR 312.160 - Drugs for investigational use in laboratory research animals or in vitro tests.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... research animals or in vitro tests. 312.160 Section 312.160 Food and Drugs FOOD AND DRUG ADMINISTRATION... Drugs for Investigational Use in Laboratory Research Animals or In Vitro Tests § 312.160 Drugs for investigational use in laboratory research animals or in vitro tests. (a) Authorization to ship. (1)(i) A person...

  1. 21 CFR 312.160 - Drugs for investigational use in laboratory research animals or in vitro tests.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... research animals or in vitro tests. 312.160 Section 312.160 Food and Drugs FOOD AND DRUG ADMINISTRATION... Drugs for Investigational Use in Laboratory Research Animals or In Vitro Tests § 312.160 Drugs for investigational use in laboratory research animals or in vitro tests. (a) Authorization to ship. (1)(i) A person...

  2. 21 CFR 312.160 - Drugs for investigational use in laboratory research animals or in vitro tests.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... research animals or in vitro tests. 312.160 Section 312.160 Food and Drugs FOOD AND DRUG ADMINISTRATION... Drugs for Investigational Use in Laboratory Research Animals or In Vitro Tests § 312.160 Drugs for investigational use in laboratory research animals or in vitro tests. (a) Authorization to ship. (1)(i) A person...

  3. 21 CFR 312.160 - Drugs for investigational use in laboratory research animals or in vitro tests.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... research animals or in vitro tests. 312.160 Section 312.160 Food and Drugs FOOD AND DRUG ADMINISTRATION... Drugs for Investigational Use in Laboratory Research Animals or In Vitro Tests § 312.160 Drugs for investigational use in laboratory research animals or in vitro tests. (a) Authorization to ship. (1)(i) A person...

  4. SUSCEPTIBILITY TEST FOR FUNGI: CLINICAL AND LABORATORIAL CORRELATIONS IN MEDICAL MYCOLOGY.

    PubMed

    Alastruey-Izquierdo, Ana; Melhem, Marcia S C; Bonfietti, Lucas X; Rodriguez-Tudela, Juan L

    2015-09-01

    During recent decades, antifungal susceptibility testing has become standardized and nowadays has the same role of the antibacterial susceptibility testing in microbiology laboratories. American and European standards have been developed, as well as equivalent commercial systems which are more appropriate for clinical laboratories. The detection of resistant strains by means of these systems has allowed the study and understanding of the molecular basis and the mechanisms of resistance of fungal species to antifungal agents. In addition, many studies on the correlation of in vitro results with the outcome of patients have been performed, reaching the conclusion that infections caused by resistant strains have worse outcome than those caused by susceptible fungal isolates. These studies have allowed the development of interpretative breakpoints for Candida spp. and Aspergillus spp., the most frequent agents of fungal infections in the world. In summary, antifungal susceptibility tests have become essential tools to guide the treatment of fungal diseases, to know the local and global disease epidemiology, and to identify resistance to antifungals.

  5. 49 CFR 40.91 - What validity tests must laboratories conduct on primary specimens?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.91 What... testing under § 40.89, you must conduct it in accordance with the requirements of this section. (a) You... responses characteristic of an adulterant obtained during initial or confirmatory drug tests (e.g., non...

  6. 49 CFR 40.91 - What validity tests must laboratories conduct on primary specimens?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.91 What... testing under § 40.89, you must conduct it in accordance with the requirements of this section. (a) You... responses characteristic of an adulterant obtained during initial or confirmatory drug tests (e.g., non...

  7. 49 CFR 40.91 - What validity tests must laboratories conduct on primary specimens?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.91 What... testing under § 40.89, you must conduct it in accordance with the requirements of this section. (a) You... responses characteristic of an adulterant obtained during initial or confirmatory drug tests (e.g., non...

  8. 49 CFR 40.91 - What validity tests must laboratories conduct on primary specimens?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.91 What... testing under § 40.89, you must conduct it in accordance with the requirements of this section. (a) You... responses characteristic of an adulterant obtained during initial or confirmatory drug tests (e.g., non...

  9. 49 CFR 40.91 - What validity tests must laboratories conduct on primary specimens?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.91 What... testing under § 40.89, you must conduct it in accordance with the requirements of this section. (a) You... responses characteristic of an adulterant obtained during initial or confirmatory drug tests (e.g., non...

  10. Use of the laboratory tests of soil modulus in modelling pile behaviour

    NASA Astrophysics Data System (ADS)

    Dyka, Ireneusz

    2012-10-01

    This article deals with the question of theoretical description of behaviour of a single pile rested in a layered soil medium. Particular attention is paid to soil modulus which is used in calculation method for pile load-settlement curve. A brief analysis of the results obtained by laboratory tests to assess soil modulus and its nonlinear variability has been presented. The results of tests have been used in triaxial apparatus and resonant column/torsional shear device. There have also been presented the results of load-settlement calculation for a single pile under axial load with implementation of different models of soil modulus degradation. On this basis, possibilities of using particular kinds of laboratory tests in calculation procedure of foundation settlement have been presented as well as further developments of them.

  11. Choosing the right laboratory: a review of clinical and forensic toxicology services for urine drug testing in pain management.

    PubMed

    Reisfield, Gary M; Goldberger, Bruce A; Bertholf, Roger L

    2015-01-01

    Urine drug testing (UDT) services are provided by a variety of clinical, forensic, and reference/specialty laboratories. These UDT services differ based on the principal activity of the laboratory. Clinical laboratories provide testing primarily focused on medical care (eg, emergency care, inpatients, and outpatient clinics), whereas forensic laboratories perform toxicology tests related to postmortem and criminal investigations, and drug-free workplace programs. Some laboratories now provide UDT specifically designed for monitoring patients on chronic opioid therapy. Accreditation programs for clinical laboratories have existed for nearly half a century, and a federal certification program for drug-testing laboratories was established in the 1980s. Standards of practice for forensic toxicology services other than workplace drug testing have been established in recent years. However, no accreditation program currently exists for UDT in pain management, and this review considers several aspects of laboratory accreditation and certification relevant to toxicology services, with the intention to provide guidance to clinicians in their selection of the appropriate laboratory for UDT surveillance of their patients on opioid therapy.

  12. EVALUATION OF MIXING ENERGY IN LABORATORY FLASKS USED FOR DISPERSANT EFFECTIVENESS TESTING

    EPA Science Inventory

    The evaluation of dispersant effectiveness used for oil spills is commonly done using tests conducted in laboratory flasks. The success of a test relies on replication of the conditions at sea. We used a hot wire anemometer to characterize the turbulence characteristics in the s...

  13. Portuguese Family Physicians’ Awareness of Diagnostic and Laboratory Test Costs: A Cross-Sectional Study

    PubMed Central

    Sá, Luísa; Costa-Santos, Cristina; Teixeira, Andreia; Couto, Luciana; Costa-Pereira, Altamiro; Hespanhol, Alberto; Santos, Paulo; Martins, Carlos

    2015-01-01

    Background Physicians’ ability to make cost-effective decisions has been shown to be affected by their knowledge of health care costs. This study assessed whether Portuguese family physicians are aware of the costs of the most frequently prescribed diagnostic and laboratory tests. Methods A cross-sectional study was conducted in a representative sample of Portuguese family physicians, using computer-assisted telephone interviews for data collection. A Likert scale was used to assess physician’s level of agreement with four statements about health care costs. Family physicians were also asked to estimate the costs of diagnostic and laboratory tests. Each physician’s cost estimate was compared with the true cost and the absolute error was calculated. Results One-quarter (24%; 95% confidence interval: 23%–25%) of all cost estimates were accurate to within 25% of the true cost, with 55% (95% IC: 53–56) overestimating and 21% (95% IC: 20–22) underestimating the true actual cost. The majority (76%) of family physicians thought they did not have or were uncertain as to whether they had adequate knowledge of diagnostic and laboratory test costs, and only 7% reported receiving adequate education. The majority of the family physicians (82%) said that they had adequate access to information about the diagnostic and laboratory test costs. Thirty-three percent thought that costs did not influence their decision to order tests, while 27% were uncertain. Conclusions Portuguese family physicians have limited awareness of diagnostic and laboratory test costs, and our results demonstrate a need for improved education in this area. Further research should focus on identifying whether interventions in cost knowledge actually change ordering behavior, in identifying optimal methods to disseminate cost information, and on improving the cost-effectiveness of care. PMID:26356625

  14. Open-source Software for Demand Forecasting of Clinical Laboratory Test Volumes Using Time-series Analysis.

    PubMed

    Mohammed, Emad A; Naugler, Christopher

    2017-01-01

    Demand forecasting is the area of predictive analytics devoted to predicting future volumes of services or consumables. Fair understanding and estimation of how demand will vary facilitates the optimal utilization of resources. In a medical laboratory, accurate forecasting of future demand, that is, test volumes, can increase efficiency and facilitate long-term laboratory planning. Importantly, in an era of utilization management initiatives, accurately predicted volumes compared to the realized test volumes can form a precise way to evaluate utilization management initiatives. Laboratory test volumes are often highly amenable to forecasting by time-series models; however, the statistical software needed to do this is generally either expensive or highly technical. In this paper, we describe an open-source web-based software tool for time-series forecasting and explain how to use it as a demand forecasting tool in clinical laboratories to estimate test volumes. This tool has three different models, that is, Holt-Winters multiplicative, Holt-Winters additive, and simple linear regression. Moreover, these models are ranked and the best one is highlighted. This tool will allow anyone with historic test volume data to model future demand.

  15. Open-source Software for Demand Forecasting of Clinical Laboratory Test Volumes Using Time-series Analysis

    PubMed Central

    Mohammed, Emad A.; Naugler, Christopher

    2017-01-01

    Background: Demand forecasting is the area of predictive analytics devoted to predicting future volumes of services or consumables. Fair understanding and estimation of how demand will vary facilitates the optimal utilization of resources. In a medical laboratory, accurate forecasting of future demand, that is, test volumes, can increase efficiency and facilitate long-term laboratory planning. Importantly, in an era of utilization management initiatives, accurately predicted volumes compared to the realized test volumes can form a precise way to evaluate utilization management initiatives. Laboratory test volumes are often highly amenable to forecasting by time-series models; however, the statistical software needed to do this is generally either expensive or highly technical. Method: In this paper, we describe an open-source web-based software tool for time-series forecasting and explain how to use it as a demand forecasting tool in clinical laboratories to estimate test volumes. Results: This tool has three different models, that is, Holt-Winters multiplicative, Holt-Winters additive, and simple linear regression. Moreover, these models are ranked and the best one is highlighted. Conclusion: This tool will allow anyone with historic test volume data to model future demand. PMID:28400996

  16. Soils Sampling and Testing Training Guide for Field and Laboratory Technicians on Roadway Construction

    DOT National Transportation Integrated Search

    1999-12-01

    This manual has been developed as a training guide for field and laboratory technicians responsible for sampling and testing of soils used in roadway construction. Soils training and certification will increase the knowledge of laboratory, production...

  17. Current issues of personnel and laboratory practices in genetic testing

    PubMed Central

    Mark, Hon Fong Louie; Kelly, Thaddeus; Watson, Michael S; Hoeltge, Gerald; Miller, Wayne A; Beauregard, Laurent

    1995-01-01

    As genetic testing is an area with implications extending far beyond that of the primary patient, it is appropriately an area that is under increased scrutiny. To ensure that high quality is maintained in the delivery of genetic services, several agencies have developed standards and guidelines. The present article summarises important recommendations made by the American College of Medical Genetics (ACMG), the College of American Pathologists (CAP), the US Health Care Financing Administration (HCFA), and the US Food and Drug Administration (FDA) as they relate to genetic testing. Some of the standards are based on voluntary compliance, whereas others have the force of regulation. They all address issues of personnel credentials, laboratory operations, and the most critical quality assurance and control measures for diagnostic laboratories from the perspective of various agencies. In most instances, the standards promulgated by these agencies are offered as minimum criteria. The exact impact of these regulations on the practice of medical genetics has yet to be established. Images PMID:8558555

  18. Economic evaluation of laboratory testing strategies for hospital-associated Clostridium difficile infection.

    PubMed

    Schroeder, Lee F; Robilotti, Elizabeth; Peterson, Lance R; Banaei, Niaz; Dowdy, David W

    2014-02-01

    Clostridium difficile infection (CDI) is the most common cause of infectious diarrhea in health care settings, and for patients presumed to have CDI, their isolation while awaiting laboratory results is costly. Newer rapid tests for CDI may reduce this burden, but the economic consequences of different testing algorithms remain unexplored. We used decision analysis from the hospital perspective to compare multiple CDI testing algorithms for adult inpatients with suspected CDI, assuming patient management according to laboratory results. CDI testing strategies included combinations of on-demand PCR (odPCR), batch PCR, lateral-flow diagnostics, plate-reader enzyme immunoassay, and direct tissue culture cytotoxicity. In the reference scenario, algorithms incorporating rapid testing were cost-effective relative to nonrapid algorithms. For every 10,000 symptomatic adults, relative to a strategy of treating nobody, lateral-flow glutamate dehydrogenase (GDH)/odPCR generated 831 true-positive results and cost $1,600 per additional true-positive case treated. Stand-alone odPCR was more effective and more expensive, identifying 174 additional true-positive cases at $6,900 per additional case treated. All other testing strategies were dominated by (i.e., more costly and less effective than) stand-alone odPCR or odPCR preceded by lateral-flow screening. A cost-benefit analysis (including estimated costs of missed cases) favored stand-alone odPCR in most settings but favored odPCR preceded by lateral-flow testing if a missed CDI case resulted in less than $5,000 of extended hospital stay costs and <2 transmissions, if lateral-flow GDH diagnostic sensitivity was >93%, or if the symptomatic carrier proportion among the toxigenic culture-positive cases was >80%. These results can aid guideline developers and laboratory directors who are considering rapid testing algorithms for diagnosing CDI.

  19. Economic Evaluation of Laboratory Testing Strategies for Hospital-Associated Clostridium difficile Infection

    PubMed Central

    Robilotti, Elizabeth; Peterson, Lance R.; Banaei, Niaz; Dowdy, David W.

    2014-01-01

    Clostridium difficile infection (CDI) is the most common cause of infectious diarrhea in health care settings, and for patients presumed to have CDI, their isolation while awaiting laboratory results is costly. Newer rapid tests for CDI may reduce this burden, but the economic consequences of different testing algorithms remain unexplored. We used decision analysis from the hospital perspective to compare multiple CDI testing algorithms for adult inpatients with suspected CDI, assuming patient management according to laboratory results. CDI testing strategies included combinations of on-demand PCR (odPCR), batch PCR, lateral-flow diagnostics, plate-reader enzyme immunoassay, and direct tissue culture cytotoxicity. In the reference scenario, algorithms incorporating rapid testing were cost-effective relative to nonrapid algorithms. For every 10,000 symptomatic adults, relative to a strategy of treating nobody, lateral-flow glutamate dehydrogenase (GDH)/odPCR generated 831 true-positive results and cost $1,600 per additional true-positive case treated. Stand-alone odPCR was more effective and more expensive, identifying 174 additional true-positive cases at $6,900 per additional case treated. All other testing strategies were dominated by (i.e., more costly and less effective than) stand-alone odPCR or odPCR preceded by lateral-flow screening. A cost-benefit analysis (including estimated costs of missed cases) favored stand-alone odPCR in most settings but favored odPCR preceded by lateral-flow testing if a missed CDI case resulted in less than $5,000 of extended hospital stay costs and <2 transmissions, if lateral-flow GDH diagnostic sensitivity was >93%, or if the symptomatic carrier proportion among the toxigenic culture-positive cases was >80%. These results can aid guideline developers and laboratory directors who are considering rapid testing algorithms for diagnosing CDI. PMID:24478478

  20. Performance specifications for the extra-analytical phases of laboratory testing: Why and how.

    PubMed

    Plebani, Mario

    2017-07-01

    An important priority in the current healthcare scenario should be to address errors in laboratory testing, which account for a significant proportion of diagnostic errors. Efforts made in laboratory medicine to enhance the diagnostic process have been directed toward improving technology, greater volumes and more accurate laboratory tests being achieved, but data collected in the last few years highlight the need to re-evaluate the total testing process (TTP) as the unique framework for improving quality and patient safety. Valuable quality indicators (QIs) and extra-analytical performance specifications are required for guidance in improving all TTP steps. Yet in literature no data are available on extra-analytical performance specifications based on outcomes, and nor is it possible to set any specification using calculations involving biological variability. The collection of data representing the state-of-the-art based on quality indicators is, therefore, underway. The adoption of a harmonized set of QIs, a common data collection and standardised reporting method is mandatory as it will not only allow the accreditation of clinical laboratories according to the International Standard, but also assure guidance for promoting improvement processes and guaranteeing quality care to patients. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  1. Mounted Smartphones as Measurement and Control Platforms for Motor-Based Laboratory Test-Beds †

    PubMed Central

    Frank, Jared A.; Brill, Anthony; Kapila, Vikram

    2016-01-01

    Laboratory education in science and engineering often entails the use of test-beds equipped with costly peripherals for sensing, acquisition, storage, processing, and control of physical behavior. However, costly peripherals are no longer necessary to obtain precise measurements and achieve stable feedback control of test-beds. With smartphones performing diverse sensing and processing tasks, this study examines the feasibility of mounting smartphones directly to test-beds to exploit their embedded hardware and software in the measurement and control of the test-beds. This approach is a first step towards replacing laboratory-grade peripherals with more compact and affordable smartphone-based platforms, whose interactive user interfaces can engender wider participation and engagement from learners. Demonstrative cases are presented in which the sensing, computation, control, and user interaction with three motor-based test-beds are handled by a mounted smartphone. Results of experiments and simulations are used to validate the feasibility of mounted smartphones as measurement and feedback control platforms for motor-based laboratory test-beds, report the measurement precision and closed-loop performance achieved with such platforms, and address challenges in the development of platforms to maintain system stability. PMID:27556464

  2. An inter-laboratory comparison study of the ANSI/BIFMA standard test method M7.1 for furniture

    EPA Science Inventory

    Five laboratories using five different test chambers participated in the study to quantify within- and between-laboratory variability in the measurement of emissions of volatile organic compounds (VOCs) from new commercial furniture test items following ANSI/BIFMA M7.1. Test item...

  3. Laboratory testing and economic analysis of high RAP warm mixed asphalt.

    DOT National Transportation Integrated Search

    2009-03-24

    This report contains laboratory testing, economic analysis, literature review, and information obtained from multiple producers throughout the state of Mississippi regarding the use of high RAP (50 % to 100%) mixtures containing warm mix additives. T...

  4. 49 CFR Appendix B to Part 219 - Designation of Laboratory for Post-Accident Toxicological Testing

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Designation of Laboratory for Post-Accident.... 219, App. B Appendix B to Part 219—Designation of Laboratory for Post-Accident Toxicological Testing The following laboratory is currently designated to conduct post-accident toxicological analysis under...

  5. Idaho National Engineering Laboratory, Test Area North, Hangar 629 -- Photographs, written historical and descriptive data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1994-12-31

    The report describes the history of the Idaho National Engineering Laboratory`s Hangar 629. The hangar was built to test the possibility of linking jet engine technology with nuclear power. The history of the project is described along with the development and eventual abandonment of the Flight Engine Test hangar. The report contains historical photographs and architectural drawings.

  6. Bridging naturalistic and laboratory assessment of memory: the Baycrest mask fit test.

    PubMed

    Armson, Michael J; Abdi, Hervé; Levine, Brian

    2017-09-01

    Autobiographical memory tests provide a naturalistic counterpoint to the artificiality of laboratory research methods, yet autobiographical events are uncontrolled and, in most cases, unverifiable. In this study, we capitalised on a scripted, complex naturalistic event - the mask fit test (MFT), a standardised procedure required of hospital employees - to bridge the gap between naturalistic and laboratory memory assessment. We created a test of recognition memory for the MFT and administered it to 135 hospital employees who had undertaken the MFT at various points over the past five years. Multivariate analysis revealed two dimensions defined by accuracy and response bias. Accuracy scores showed the expected relationship to encoding-test delay, supporting the validity of this measure. Relative to younger adults, older adults' memory for this naturalistic event was better than would be predicted from the cognitive ageing literature, a result consistent with the notion that older adults' memory performance is enhanced when stimuli are naturalistic and personally relevant. These results demonstrate that testing recognition memory for a scripted event is a viable method of studying autobiographical memory.

  7. Creating Best Practices for the Submission of Actionable Food and Feed Testing Data Generated in State and Local Laboratories.

    PubMed

    Wangsness, Kathryn; Salfinger, Yvonne; Randolph, Robyn; Shea, Shari; Larson, Kirsten

    2017-07-01

    Laboratory accreditation provides a level of standardization in laboratories and confidence in generated food and feed testing results. For some laboratories, ISO/IEC 17025:2005 accreditation may not be fiscally viable, or a requested test method may be out of the scope of the laboratory's accreditation. To assist laboratories for whom accreditation is not feasible, the Association of Public Health Laboratories Data Acceptance Work Group developed a white paper entitled "Best Practices for Submission of Actionable Food and Feed Testing Data Generated in State and Local Laboratories." The basic elements of a quality management system, along with other best practices that state and local food and feed testing laboratories should follow, are included in the white paper. It also covers program-specific requirements that may need to be addressed. Communication with programs and end data users is regarded as essential for establishing the reliability and accuracy of laboratory data. Following these suggested best practices can facilitate the acceptance of laboratory data, which can result in swift regulatory action and the quick removal of contaminated product from the food supply, improving public health nationally.

  8. Predictive value and efficiency of laboratory testing.

    PubMed

    Galen, R S

    1980-11-01

    Literature on determining reference values and reference intervals on "normal" or "healthy" individuals is abundant. It is impossible, however, to evaluate a data set of reference values and select a suitable reference interval that will be meaningful for the practice of medicine. The reference interval, no matter how derived statistically, tells us nothing about disease. This is the main reason the concepts of "normal values" have failed us and why "reference values" will prove similarly disappointing. By studying these same constituents in a variety of disease states as well, it will be possible to select "referent values" that will make the test procedure meaningful for diagnostic purposes. In order to obtain meaningful referent values for predicting disease, it is necessary to study not only the "healthy" reference population, but patients with the disease in question, and patients who are free of the disease in question but who have other diseases. Studies of this type are not frequently found for laboratory tests that are in common use today.

  9. 46 CFR 159.007-3 - Production inspections and tests: Independent laboratory's procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Production inspections and tests: Independent laboratory's procedures. 159.007-3 Section 159.007-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL APPROVAL OF EQUIPMENT AND MATERIALS Production Inspection and Tests of...

  10. 46 CFR 159.007-3 - Production inspections and tests: Independent laboratory's procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Production inspections and tests: Independent laboratory's procedures. 159.007-3 Section 159.007-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL APPROVAL OF EQUIPMENT AND MATERIALS Production Inspection and Tests of...

  11. HIT or miss? A comprehensive contemporary investigation of laboratory tests for heparin induced thrombocytopenia.

    PubMed

    Favaloro, Emmanuel J; McCaughan, Georgia; Mohammed, Soma; Lau, Kun Kan Edwin; Gemmell, Rosalie; Cavanaugh, Lauren; Donikian, Dea; Kondo, Mayuko; Brighton, Timothy; Pasalic, Leonardo

    2018-04-17

    Heparin induced thrombocytopenia (HIT) is a rare but potentially fatal complication of heparin therapy, which in a proportion of patients causes platelet activation and thrombosis. Initial clinical assessment of the likelihood of HIT is facilitated by laboratory testing to confirm or exclude HIT. This prospective investigation was performed over an 18-month period, and has involved testing of over 300 test samples from over 100 consecutive patients. Clinical assessment by 4T score was supplemented by laboratory tests that comprised both immunological [lateral flow ('STiC'), chemiluminescence (AcuStar; HIT-IgG (PF4-H) ), ELISA (Asserachrom HPIA IgG)] and functional assays [SRA, platelet aggregation using whole blood ('Multiplate') and platelet rich plasma ('LTA')]. We observed both false positive and false negative test findings with most assays. Overall, the whole blood aggregation method provided a reasonable alternative to SRA for identifying functional HIT. STiC, AcuStar and ELISA procedures were fairly comparable in terms of screening for HIT, although STiC and AcuStar both yielded false negatives, albeit also resulting in fewer false positives than ELISA. The 4T score had less utility in our patient cohort than we were expecting, although there was an association with the likelihood of HIT. Nevertheless, we accept that our observations are based on limited test numbers. In conclusion, no single approach (clinical or laboratory) was associated with optimal sensitivity or specificity of HIT exclusion or identification, and thus, a combination of clinical evaluation and laboratory testing will best ensure the accuracy of diagnosis. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  12. Hot Corrosion Test Facility at the NASA Lewis Special Projects Laboratory

    NASA Technical Reports Server (NTRS)

    Robinson, Raymond C.; Cuy, Michael D.

    1994-01-01

    The Hot Corrosion Test Facility (HCTF) at the NASA Lewis Special Projects Laboratory (SPL) is a high-velocity, pressurized burner rig currently used to evaluate the environmental durability of advanced ceramic materials such as SiC and Si3N4. The HCTF uses laboratory service air which is preheated, mixed with jet fuel, and ignited to simulate the conditions of a gas turbine engine. Air, fuel, and water systems are computer-controlled to maintain test conditions which include maximum air flows of 250 kg/hr (550 lbm/hr), pressures of 100-600 kPa (1-6 atm), and gas temperatures exceeding 1500 C (2732 F). The HCTF provides a relatively inexpensive, yet sophisticated means for researchers to study the high-temperature oxidation of advanced materials, and the injection of a salt solution provides the added capability of conducting hot corrosion studies.

  13. Inverter testing at Sandia National Laboratories

    NASA Astrophysics Data System (ADS)

    Ginn, Jerry W.; Bonn, Russell H.; Sittler, Greg

    1997-02-01

    Inverters are key building blocks of photovoltaic (PV) systems that produce ac power. The balance of systems (BOS) portion of a PV system can account for up to 50% of the system cost, and its reliable operation is essential for a successful PV system. As part of its BOS program, Sandia National Laboratories (SNL) maintains a laboratory wherein accurate electrical measurements of power systems can be made under a variety of conditions. This paper outlines the work that is done in that laboratory.

  14. Molecular genetic testing for cystic fibrosis: laboratory performance on the College of American Pathologists external proficiency surveys.

    PubMed

    Lyon, Elaine; Schrijver, Iris; Weck, Karen E; Ferreira-Gonzalez, Andrea; Richards, C Sue; Palomaki, Glenn E

    2015-03-01

    Molecular testing for cystic fibrosis mutations is widespread and routine in reproductive decision making and diagnosis. Our objective was to assess the level of performance of laboratories for this test. The College of American Pathologists administers external proficiency testing with multiple DNA samples distributed biannually. RESULTS are analyzed, reviewed, and graded by the joint College of American Pathologists/American College of Medical Genetics and Genomics Biochemical and Molecular Genetics Committee. Assessment is based on genotype and associated clinical interpretation. Overall, 357 clinical laboratories participated in the proficiency testing survey between 2003 and 2013 (322 in the United States and 35 international). In 2013, US participants reported performing nearly 120,000 tests monthly. Analytical sensitivity and specificity of US laboratories were 98.8% (95% confidence interval: 98.4-99.1%) and 99.6% (95% confidence interval: 99.4-99.7%), respectively. Analytical sensitivity improved between 2003 and 2008 (from 97.9 to 99.3%; P = 0.007) and remained steady thereafter. Clinical interpretation matched the intended response for 98.8, 86.0, and 91.0% of challenges with no, one, or two mutations, respectively. International laboratories performed similarly. Laboratory testing for cystic fibrosis in the United States has improved since 2003, and these data demonstrate a high level of quality. Neither the number of samples tested nor test methodology affected performance.

  15. The effects of calculator-based laboratories on standardized test scores

    NASA Astrophysics Data System (ADS)

    Stevens, Charlotte Bethany Rains

    Nationwide, the goal of providing a productive science and math education to our youth in today's educational institutions is centering itself around the technology being utilized in these classrooms. In this age of digital technology, educational software and calculator-based laboratories (CBL) have become significant devices in the teaching of science and math for many states across the United States. Among the technology, the Texas Instruments graphing calculator and Vernier Labpro interface, are among some of the calculator-based laboratories becoming increasingly popular among middle and high school science and math teachers in many school districts across this country. In Tennessee, however, it is reported that this type of technology is not regularly utilized at the student level in most high school science classrooms, especially in the area of Physical Science (Vernier, 2006). This research explored the effect of calculator based laboratory instruction on standardized test scores. The purpose of this study was to determine the effect of traditional teaching methods versus graphing calculator teaching methods on the state mandated End-of-Course (EOC) Physical Science exam based on ability, gender, and ethnicity. The sample included 187 total tenth and eleventh grade physical science students, 101 of which belonged to a control group and 87 of which belonged to the experimental group. Physical Science End-of-Course scores obtained from the Tennessee Department of Education during the spring of 2005 and the spring of 2006 were used to examine the hypotheses. The findings of this research study suggested the type of teaching method, traditional or calculator based, did not have an effect on standardized test scores. However, the students' ability level, as demonstrated on the End-of-Course test, had a significant effect on End-of-Course test scores. This study focused on a limited population of high school physical science students in the middle Tennessee

  16. Laboratory compliance with the American Society of Clinical Oncology/college of American Pathologists guidelines for human epidermal growth factor receptor 2 testing: a College of American Pathologists survey of 757 laboratories.

    PubMed

    Nakhleh, Raouf E; Grimm, Erin E; Idowu, Michael O; Souers, Rhona J; Fitzgibbons, Patrick L

    2010-05-01

    To ensure quality human epidermal growth receptor 2 (HER2) testing in breast cancer, the American Society of Clinical Oncology/College of American Pathologists guidelines were introduced with expected compliance by 2008. To assess the effect these guidelines have had on pathology laboratories and their ability to address key components. In late 2008, a survey was distributed with the HER2 immunohistochemistry (IHC) proficiency testing program. It included questions regarding pathology practice characteristics and assay validation using fluorescence in situ hybridization or another IHC laboratory assay and assessed pathologist HER2 scoring competency. Of the 907 surveys sent, 757 (83.5%) were returned. The median laboratory accessioned 15 000 cases and performed 190 HER2 tests annually. Quantitative computer image analysis was used by 33% of laboratories. In-house fluorescence in situ hybridization was performed in 23% of laboratories, and 60% of laboratories addressed the 6- to 48-hour tissue fixation requirement by embedding tissue on the weekend. HER2 testing was performed on the initial biopsy in 40%, on the resection specimen in 6%, and on either in 56% of laboratories. Testing was validated with only fluorescence in situ hybridization in 47% of laboratories, whereas 10% of laboratories used another IHC assay only; 13% used both assays, and 12% and 15% of laboratories had not validated their assays or chose "not applicable" on the survey question, respectively. The 90% concordance rate with fluorescence in situ hybridization results was achieved by 88% of laboratories for IHC-negative findings and by 81% of laboratories for IHC-positive cases. The 90% concordance rate for laboratories using another IHC assay was achieved by 80% for negative findings and 75% for positive cases. About 91% of laboratories had a pathologist competency assessment program. This survey demonstrates the extent and characteristics of HER2 testing. Although some American Society of

  17. Comparison of estrogen receptor results from pathology reports with results from central laboratory testing.

    PubMed

    Collins, Laura C; Marotti, Jonathan D; Baer, Heather J; Tamimi, Rulla M

    2008-02-06

    We compared estrogen receptor (ER) assay results abstracted from pathology reports with ER results determined on the same specimens by a central laboratory with an immunohistochemical assay. Paraffin sections were cut from tissue microarrays containing 3093 breast cancer specimens from women enrolled in the Nurses' Health Study, 1851 of which had both pathology reports and tissue available for central laboratory testing. All sections were immunostained for ER at the same time. The original assays were biochemical for 1512 (81.7%) of the 1851 specimens, immunohistochemical for 336 (18.2%), and immunofluorescent for three (0.2%). ER results from pathology reports and repeat central laboratory testing were in agreement for 87.3% of specimens (1615 of the 1851 specimens; kappa statistic = 0.64, P < .001). When the comparison was restricted to the specimens for which the ER assays were originally performed by immunohistochemistry, the agreement rate increased to 92.3% of specimens (310 of the 336 specimens; kappa statistic = 0.78, P < .001). Thus, ER assay results from pathology reports appear to be a reasonable alternative to central laboratory ER testing for large, population-based studies of patients with breast cancer.

  18. Comparative Laboratory-Scale Testing of Dispersant Effectiveness of 23 Crude Oils Using Four Different Testing Protocols

    EPA Science Inventory

    A controlled laboratory study was conducted to measure the dispersion effectiveness of Corexit 9500 on 20 different crude oils. This study was a part of a larger project initiated by the Bureau of Safety and Environmental Enforcement (BSEE) testing 20 oils to compare the predict...

  19. Laboratory testing of clothes washers. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dieckmann, J.; Murphy, W.

    1995-12-01

    Horizontal axis (H-axis) clothes washers use less water and energy than conventional top-loading vertical axis (V-axis) clothes washers, yet sales in the US are insignificant. In the High Efficiency Laundry Metering and Market Analysis (THELMA) project, EPRI and a group of utilities have pooled their resources to develop the basis for successful DSM programs to accelerate the acceptance of this technology in the US market. This report covers the laboratory test phase of the THELMA project. The objective of this effort was to measure the performance of a representative sample of currently manufactured H-axis washers and to compare this performancemore » to that of a typical V-axis washer. Several aspects of performance were measured, with the emphasis on measures of energy consumption and water consumption: DOE washer capacity; Hot and cold water consumption; Energy consumption by the washer mechanical drive; DOE energy factor; Water extraction effectiveness; Effect of water extraction effectiveness on dryer energy; Soil removal effectiveness; Rinsing effectiveness and Gentleness of action. Six H-axis washers, provided by US or European manufacturers, were tested. Test results varied over a range for these six machines, but on average, the H-axis washers used 40% less energy (normalized to basket volume) and 25% less water (normalized to basket volume) when measured according to the DOE test procedure.« less

  20. Request of laboratory liver tests in primary care in Spain: potential savings if appropriateness indicator targets were achieved.

    PubMed

    Salinas, Maria; López-Garrigós, Maite; Flores, Emilio; Uris, Joaquín; Leiva-Salinas, Carlos

    2015-10-01

    Liver laboratory tests are used to screen for liver disease, suggest the underlying cause, estimate the severity, assess prognosis, and monitor the efficacy of therapy. The aim of this study was to compare the liver laboratory tests requesting patterns by GPs in Spain, according to geographic and hospital characteristics, to investigate the degree of requesting appropriateness. One hundred and forty-one clinical laboratories were invited to participate from diverse regions across Spain. They filed out the number of laboratory liver tests requested by GPs for the year 2012. Two types of appropriateness indicators were calculated: every test request per 1000 inhabitants or ratios of related tests requests. The indicator results obtained were compared between the different hospitals, according to their setting, location, and management. The savings generated, if each area would have achieved indicator targets, were calculated. We recruited 76 laboratories covering a population of 17,679,195 inhabitants. GPs requested 20,916,780 laboratory liver tests in the year 2012. No differences were obtained according to their setting. Lactate dehydrogenase and direct bilirubin per 1000 inhabitants were significantly higher in institutions with private management. Largest differences were observed between communities. Nine, 31, 0, and 13 laboratories, respectively, achieved the aspartate aminotransferase, lactate dehydrogenase, γ-glutamyl transpeptidase, and total bilirubin-related alanine aminotransferase indicator targets. Reaching ratios would have resulted in savings of €1,028,468. There was a high variability in the request of liver tests. This emphasizes the need to implement interventions to improve appropriate use of liver tests.

  1. 40 CFR 1048.510 - What transient duty cycles apply for laboratory testing?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false What transient duty cycles apply for... Procedures § 1048.510 What transient duty cycles apply for laboratory testing? (a) Starting with the 2007 model year, measure emissions by testing the engine on a dynamometer with the duty cycle described in...

  2. Do sediment type and test durations affect results of laboratory-based, accelerated testing studies of permeable pavement clogging?

    PubMed

    Nichols, Peter W B; White, Richard; Lucke, Terry

    2015-04-01

    Previous studies have attempted to quantify the clogging processes of Permeable Interlocking Concrete Pavers (PICPs) using accelerated testing methods. However, the results have been variable. This study investigated the effects that three different sediment types (natural and silica), and different simulated rainfall intensities, and testing durations had on the observed clogging processes (and measured surface infiltration rates) of laboratory-based, accelerated PICP testing studies. Results showed that accelerated simulated laboratory testing results are highly dependent on the type, and size of sediment used in the experiments. For example, when using real stormwater sediment up to 1.18 mm in size, the results showed that neither testing duration, nor stormwater application rate had any significant effect on PICP clogging. However, the study clearly showed that shorter testing durations generally increased clogging and reduced the surface infiltration rates of the models when artificial silica sediment was used. Longer testing durations also generally increased clogging of the models when using fine sediment (<300 μm). Results from this study will help researchers and designers better anticipate when and why PICPs are susceptible to clogging, reduce maintenance and extend the useful life of these increasingly common stormwater best management practices. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Analysis of laboratory testing results collected in an enhanced chlamydia surveillance system in Australia, 2008–2010

    PubMed Central

    2014-01-01

    Background Chlamydial infection is the most common notifiable disease in Australia, Europe and the US. Australian notifications of chlamydia rose four-fold from 20,274 cases in 2002 to 80,846 cases in 2011; the majority of cases were among young people aged less than 29 years. Along with test positivity rates, an understanding of the number of tests performed and the demographics of individuals being tested are key epidemiological indicators. The ACCESS Laboratory Network was established in 2008 to address this issue. Methods The ACCESS Laboratory Network collected chlamydia testing data from 15 laboratories around Australia over a three-year period using data extraction software. All chlamydia testing data from participating laboratories were extracted from the laboratory information system; patient identifiers converted to a unique, non-reversible code and de-identified data sent to a single database. Analysis of data by anatomical site included all specimens, but in age and sex specific analysis, only one testing episode was counted. Results From 2008 to 2010 a total of 628,295 chlamydia tests were referred to the 15 laboratories. Of the 592,626 individual episodes presenting for testing, 70% were from female and 30% from male patients. In female patients, chlamydia positivity rate was 6.4% overall; the highest rate in 14 year olds (14.3%). In male patients, the chlamydia positivity rate was 9.4% overall; the highest in 19 year olds (16.5%). The most common sample type was urine (57%). In 3.2% of testing episodes, multiple anatomical sites were sampled. Urethral swabs gave the highest positivity rate for all anatomical sites in both female (7.7%) and male patients (14%), followed by urine (7.6% and 9.4%, respectively) and eye (6.3% and 7.9%, respectively). Conclusions The ACCESS Laboratory Network data are unique in both number and scope and are representative of chlamydia testing in both general practice and high-risk clinics. The findings from these data

  4. Testing a Constrained MPC Controller in a Process Control Laboratory

    ERIC Educational Resources Information Center

    Ricardez-Sandoval, Luis A.; Blankespoor, Wesley; Budman, Hector M.

    2010-01-01

    This paper describes an experiment performed by the fourth year chemical engineering students in the process control laboratory at the University of Waterloo. The objective of this experiment is to test the capabilities of a constrained Model Predictive Controller (MPC) to control the operation of a Double Pipe Heat Exchanger (DPHE) in real time.…

  5. Laboratory test methods for evaluating the fire response of aerospace materials

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.

    1979-01-01

    The test methods which were developed or evaluated were intended to serve as means of comparing materials on the basis of specific responses under specific sets of test conditions, using apparatus, facilities, and personnel that would be within the capabilities of perhaps the majority of laboratories. Priority was given to test methods which showed promise of addressing the pre-ignition state of a potential fire. These test methods were intended to indicate which materials may present more hazard than others under specific test conditions. These test methods are discussed and arranged according to the stage of a fire to which they are most relevant. Some observations of material performance which resulted from this work are also discussed.

  6. Laboratory tests on heat treatment of ballast water using engine waste heat.

    PubMed

    Balaji, Rajoo; Lee Siang, Hing; Yaakob, Omar; Koh, Kho King; Adnan, Faizul Amri Bin; Ismail, Nasrudin Bin; Ahmad, Badruzzaman Bin; Ismail, Mohd Arif Bin; Wan Nik, W B

    2018-05-01

    Waste heat recovery from shipboard machineries could be a potential source for heat treatment of ballast water. Similar to a shipboard schematic arrangement, a laboratory-scale engine-heat exchanger set-up harvesting waste heat from jacket water and exhaust gases was erected to test the level of species' mortalities. Mortalities were also assessed under experimental conditions for cultured and natural plankton communities at laboratory level. Effect of pump impellers on species' mortalities were also tested. Exposures between 60°C and 70°C for 60 sec resulted in 80-100% mortalities. Mortalities due to pump impeller effects were observed in the range of 70-100% for zooplankton. On the laboratory-scale arrangement, >95% mortalities of phytoplankton, zooplankton and bacteria were recorded. It was demonstrated that the temperature of tropical sea waters used as secondary coolant can be raised to cause species' mortalities, employing engine exhaust gases. The results also indicated that pump impeller effects will enhance species' mortalities. The limitations of the shipboard application of this method would be the large ballast volumes, flow rates and time for treatment.

  7. Bottom-up laboratory testing of the DKIST Visible Broadband Imager (VBI)

    NASA Astrophysics Data System (ADS)

    Ferayorni, Andrew; Beard, Andrew; Cole, Wes; Gregory, Scott; Wöeger, Friedrich

    2016-08-01

    The Daniel K. Inouye Solar Telescope (DKIST) is a 4-meter solar observatory under construction at Haleakala, Hawaii [1]. The Visible Broadband Imager (VBI) is a first light instrument that will record images at the highest possible spatial and temporal resolution of the DKIST at a number of scientifically important wavelengths [2]. The VBI is a pathfinder for DKIST instrumentation and a test bed for developing processes and procedures in the areas of unit, systems integration, and user acceptance testing. These test procedures have been developed and repeatedly executed during VBI construction in the lab as part of a "test early and test often" philosophy aimed at identifying and resolving issues early thus saving cost during integration test and commissioning on summit. The VBI team recently completed a bottom up end-to-end system test of the instrument in the lab that allowed the instrument's functionality, performance, and usability to be validated against documented system requirements. The bottom up testing approach includes four levels of testing, each introducing another layer in the control hierarchy that is tested before moving to the next level. First the instrument mechanisms are tested for positioning accuracy and repeatability using a laboratory position-sensing detector (PSD). Second the real-time motion controls are used to drive the mechanisms to verify speed and timing synchronization requirements are being met. Next the high-level software is introduced and the instrument is driven through a series of end-to-end tests that exercise the mechanisms, cameras, and simulated data processing. Finally, user acceptance testing is performed on operational and engineering use cases through the use of the instrument engineering graphical user interface (GUI). In this paper we present the VBI bottom up test plan, procedures, example test cases and tools used, as well as results from test execution in the laboratory. We will also discuss the benefits realized

  8. 10 CFR 26.715 - Recordkeeping requirements for collection sites, licensee testing facilities, and laboratories...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Recordkeeping requirements for collection sites, licensee testing facilities, and laboratories certified by the Department of Health and Human Services. 26.715... laboratories certified by the Department of Health and Human Services. (a) Collection sites providing services...

  9. OECD validation study to assess intra- and inter-laboratory reproducibility of the zebrafish embryo toxicity test for acute aquatic toxicity testing.

    PubMed

    Busquet, François; Strecker, Ruben; Rawlings, Jane M; Belanger, Scott E; Braunbeck, Thomas; Carr, Gregory J; Cenijn, Peter; Fochtman, Przemyslaw; Gourmelon, Anne; Hübler, Nicole; Kleensang, André; Knöbel, Melanie; Kussatz, Carola; Legler, Juliette; Lillicrap, Adam; Martínez-Jerónimo, Fernando; Polleichtner, Christian; Rzodeczko, Helena; Salinas, Edward; Schneider, Katharina E; Scholz, Stefan; van den Brandhof, Evert-Jan; van der Ven, Leo T M; Walter-Rohde, Susanne; Weigt, Stefan; Witters, Hilda; Halder, Marlies

    2014-08-01

    The OECD validation study of the zebrafish embryo acute toxicity test (ZFET) for acute aquatic toxicity testing evaluated the ZFET reproducibility by testing 20 chemicals at 5 different concentrations in 3 independent runs in at least 3 laboratories. Stock solutions and test concentrations were analytically confirmed for 11 chemicals. Newly fertilised zebrafish eggs (20/concentration and control) were exposed for 96h to chemicals. Four apical endpoints were recorded daily as indicators of acute lethality: coagulation of the embryo, lack of somite formation, non-detachment of the tail bud from the yolk sac and lack of heartbeat. Results (LC50 values for 48/96h exposure) show that the ZFET is a robust method with a good intra- and inter-laboratory reproducibility (CV<30%) for most chemicals and laboratories. The reproducibility was lower (CV>30%) for some very toxic or volatile chemicals, and chemicals tested close to their limit of solubility. The ZFET is now available as OECD Test Guideline 236. Considering the high predictive capacity of the ZFET demonstrated by Belanger et al. (2013) in their retrospective analysis of acute fish toxicity and fish embryo acute toxicity data, the ZFET is ready to be considered for acute fish toxicity for regulatory purposes. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.

  10. Environmental testing philosophy for a Sandia National Laboratories small satellite project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cap, J.S.; Rackley, N.G.

    1996-03-01

    Sandia National Laboratories is the system integrator on a small satellite project. Following the intent of the NASA GEVS document, an integrated test philosophy was formulated to certify the satellite for flight. The purpose of this paper is to present that philosophy.

  11. 42 CFR 493.807 - Condition: Reinstatement of laboratories performing nonwaived testing.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., subspecialties, analyte or test, or voluntarily withdraws its certification under CLIA for the failed specialty, subspecialty, or analyte, the laboratory must then demonstrate sustained satisfactory performance on two... reinstatement for certification and Medicare or Medicaid approval in that specialty, subspecialty, analyte or...

  12. 42 CFR 493.807 - Condition: Reinstatement of laboratories performing nonwaived testing.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., subspecialties, analyte or test, or voluntarily withdraws its certification under CLIA for the failed specialty, subspecialty, or analyte, the laboratory must then demonstrate sustained satisfactory performance on two... reinstatement for certification and Medicare or Medicaid approval in that specialty, subspecialty, analyte or...

  13. 42 CFR 493.807 - Condition: Reinstatement of laboratories performing nonwaived testing.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., subspecialties, analyte or test, or voluntarily withdraws its certification under CLIA for the failed specialty, subspecialty, or analyte, the laboratory must then demonstrate sustained satisfactory performance on two... reinstatement for certification and Medicare or Medicaid approval in that specialty, subspecialty, analyte or...

  14. Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing

    PubMed Central

    Espy, M. J.; Uhl, J. R.; Sloan, L. M.; Buckwalter, S. P.; Jones, M. F.; Vetter, E. A.; Yao, J. D. C.; Wengenack, N. L.; Rosenblatt, J. E.; Cockerill, F. R.; Smith, T. F.

    2006-01-01

    Real-time PCR has revolutionized the way clinical microbiology laboratories diagnose many human microbial infections. This testing method combines PCR chemistry with fluorescent probe detection of amplified product in the same reaction vessel. In general, both PCR and amplified product detection are completed in an hour or less, which is considerably faster than conventional PCR detection methods. Real-time PCR assays provide sensitivity and specificity equivalent to that of conventional PCR combined with Southern blot analysis, and since amplification and detection steps are performed in the same closed vessel, the risk of releasing amplified nucleic acids into the environment is negligible. The combination of excellent sensitivity and specificity, low contamination risk, and speed has made real-time PCR technology an appealing alternative to culture- or immunoassay-based testing methods for diagnosing many infectious diseases. This review focuses on the application of real-time PCR in the clinical microbiology laboratory. PMID:16418529

  15. The concordance of serial ANA tests in an Australian tertiary hospital pathology laboratory.

    PubMed

    Lee, Adrian Y S; Hudspeth, Andrew R; Adelstein, Stephen

    2016-10-01

    The antinuclear antibody (ANA) tests are some of the more frequently requested tests for the diagnosis of autoimmunity. Although they are used primarily as diagnostic blood tests, multiple requests on the same patient continue to be encountered in the laboratory. This retrospective analysis of serial ANA testing at one pathology laboratory in Australia is the first study that examines the statistical concordance and possible implications of this on clinical practice. High-titred ANA have quite good repeatability for titre and pattern, and low-titred ANA, which can be non-specific, have poor repeatability. Staining patterns are, in general, almost random in nature on serial tests when compared to the first-obtained ANA pattern for each patient. This study confirms that there is little benefit in serial ANA testing, and only if there is a clear change in the patient's clinical picture would repeat of an initial low-titred ANA be useful. The findings reinforce the need for pathology stewardship to minimise costs, wasted resources and unnecessary referrals. Copyright © 2016 Royal College of Pathologists of Australasia. All rights reserved.

  16. Comparison of Field and Laboratory-Based Tests for Behavioral Response of Aedes aegypti (Diptera: Culicidae) to Repellents.

    PubMed

    Sathantriphop, Sunaiyana; Kongmee, Monthathip; Tainchum, Krajana; Suwansirisilp, Kornwika; Sanguanpong, Unchalee; Bangs, Michael J; Chareonviriyaphap, Theeraphap

    2015-12-01

    The repellent and irritant effects of three essential oils-clove, hairy basil, and sweet basil-were compared using an excito-repellency test system against an insecticide-resistant strain of Aedes aegypti (L.) females from Pu Teuy, Kanchanaburi Province. DEET was used as the comparison standard compound. Tests were conducted under field and controlled laboratory conditions. The most marked repellent effect (spatial noncontact assay) among the three test essential oils was exhibited by sweet basil, Ocimum basilicum L. (53.8% escaped mosquitoes in 30-min exposure period) under laboratory conditions while hairy basil, Ocimum americanum L. and clove, Syzygium aromaticum (L.) Merill et. L.M. Perry from laboratory tests and sweet basil from field tests were the least effective as repellents (0-14%). In contrast, the contact assays measuring combined irritancy (excitation) and repellency effects found the best contact irritant response to hairy basil and DEET in field tests, whereas all others in laboratory and field were relatively ineffective in stimulating mosquitoes to move out the test chambers (0-5.5%). All three essential oils demonstrated significant differences in behavioral responses between field and laboratory conditions, whereas there was no significant difference in contact and noncontact assays for DEET between the two test conditions (P > 0.05). © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Acoustic emissions verification testing of International Space Station experiment racks at the NASA Glenn Research Center Acoustical Testing Laboratory

    NASA Astrophysics Data System (ADS)

    Akers, James C.; Passe, Paul J.; Cooper, Beth A.

    2005-09-01

    The Acoustical Testing Laboratory (ATL) at the NASA John H. Glenn Research Center (GRC) in Cleveland, OH, provides acoustic emission testing and noise control engineering services for a variety of specialized customers, particularly developers of equipment and science experiments manifested for NASA's manned space missions. The ATL's primary customer has been the Fluids and Combustion Facility (FCF), a multirack microgravity research facility being developed at GRC for the USA Laboratory Module of the International Space Station (ISS). Since opening in September 2000, ATL has conducted acoustic emission testing of components, subassemblies, and partially populated FCF engineering model racks. The culmination of this effort has been the acoustic emission verification tests on the FCF Combustion Integrated Rack (CIR) and Fluids Integrated Rack (FIR), employing a procedure that incorporates ISO 11201 (``Acoustics-Noise emitted by machinery and equipment-Measurement of emission sound pressure levels at a work station and at other specified positions-Engineering method in an essentially free field over a reflecting plane''). This paper will provide an overview of the test methodology, software, and hardware developed to perform the acoustic emission verification tests on the CIR and FIR flight racks and lessons learned from these tests.

  18. 75 FR 39023 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-07

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were first published in the... of Laboratories Engaged in Urine Drug Testing for Federal Agencies,'' sets strict standards that...

  19. 75 FR 27348 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-14

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were first published in the... of Laboratories Engaged in Urine Drug Testing for Federal Agencies,'' sets strict standards that...

  20. 75 FR 9229 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-01

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were first published in the... of Laboratories Engaged in Urine Drug Testing for Federal Agencies,'' sets strict standards that...

  1. 75 FR 5088 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-01

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were first published in the... of Laboratories Engaged in Urine Drug Testing for Federal Agencies,'' sets strict standards that...

  2. 75 FR 154 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-04

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were first published in the... of Laboratories Engaged in Urine Drug Testing for Federal Agencies,'' sets strict standards that...

  3. 75 FR 32950 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-10

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were first published in the... of Laboratories Engaged in Urine Drug Testing for Federal Agencies,'' sets strict standards that...

  4. 75 FR 55795 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-14

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were first published in the... of Laboratories Engaged in Urine Drug Testing for Federal Agencies,'' sets strict standards that...

  5. Effect of Social Comparison Feedback on Laboratory Test Ordering for Hospitalized Patients: A Randomized Controlled Trial.

    PubMed

    Ryskina, Kira; Jessica Dine, C; Gitelman, Yevgeniy; Leri, Damien; Patel, Mitesh; Kurtzman, Gregory; Lin, Lisa Y; Epstein, Andrew J

    2018-05-22

    Social comparison feedback is an increasingly popular strategy that uses performance report cards to modify physician behavior. Our objective was to test the effect of such feedback on the ordering of routine laboratory tests for hospitalized patients, a practice considered overused. This was a single-blinded randomized controlled trial. Between January and June 2016, physicians on six general medicine teams at the Hospital of the University of Pennsylvania were cluster randomized with equal allocation to two arms: (1) those e-mailed a summary of their routine laboratory test ordering vs. the service average for the prior week, linked to a continuously updated personalized dashboard containing patient-level details, and snapshot of the dashboard and (2) those who did not receive the intervention. The primary outcome was the count of routine laboratory test orders placed by a physician per patient-day. We modeled the count of orders by each physician per patient-day after the intervention as a function of trial arm and the physician's order count before the intervention. The count outcome was modeled using negative binomial models with adjustment for clustering within teams. One hundred and fourteen interns and residents participated. We did not observe a statistically significant difference in adjusted reduction in routine laboratory ordering between the intervention and control physicians (physicians in the intervention group ordered 0.14 fewer tests per patient-day than physicians in the control group, 95% CI - 0.56 to 0.27, p = 0.50). Physicians whose absolute ordering rate deviated from the peer rate by more than 1.0 laboratory test per patient-day reduced their laboratory ordering by 0.80 orders per patient-day (95% CI - 1.58 to - 0.02, p = 0.04). Personalized social comparison feedback on routine laboratory ordering did not change targeted behavior among physicians, although there was a significant decrease in orders among participants who

  6. Laboratory test and acoustic analysis of cabin treatment for propfan test assessment aircraft

    NASA Technical Reports Server (NTRS)

    Kuntz, H. L.; Gatineau, R. J.

    1991-01-01

    An aircraft cabin acoustic enclosure, built in support of the Propfan Test Assessment (PTA) program, is described. Helmholtz resonators were attached to the cabin trim panels to increase the sidewall transmission loss (TL). Resonators (448) were located between the trim panels and fuselage shell. In addition, 152 resonators were placed between the enclosure and aircraft floors. The 600 resonators were each tuned to a 235 Hz resonance frequency. After flight testing on the PTA aircraft, the enclosure was tested in the Kelly Johnson R and D Center Acoustics Lab. Laboratory noise reduction (NR) test results are discussed. The enclosure was placed in a Gulfstream 2 fuselage section. Broadband (138 dB overall SPL) and tonal (149 dB overall SPL) excitations were used in the lab. Tonal excitation simulated the propfan flight test excitation. The fundamental tone was stepped in 2 Hz intervals from 225 through 245 Hz. The resonators increase the NR of the cabin walls around the resonance frequency of the resonator array. The effects of flanking, sidewall absorption, cabin adsorption, resonator loading of trim panels, and panel vibrations are presented. Increases in NR of up to 11 dB were measured.

  7. Clinical Laboratory Testing in the Era of Directly Acting Antiviral Therapies for Hepatitis C

    PubMed Central

    Wilson, Eleanor M.; Rosenthal, Elana S.; Kattakuzhy, Sarah; Tang, Lydia

    2016-01-01

    SUMMARY Directly acting antiviral (DAA) combination therapies for chronic hepatitis C virus (HCV) infection are highly effective, but treatment decisions remain complex. Laboratory testing is important to evaluate a range of viral, host, and pharmacological factors when considering HCV treatment, and patients must be monitored during and after therapy for safety and to assess the viral response. In this review, we discuss the laboratory tests relevant for the treatment of HCV infection in the era of DAA therapy, grouped according to viral and host factors. PMID:27795306

  8. Basic haemoglobinopathy diagnostics in Dutch laboratories; providing an informative test result.

    PubMed

    Kaufmann, J O; Smit, J W; Huisman, W; Idema, R N; Bakker, E; Giordano, P C

    2013-08-01

    After a first survey in 2001, the Dutch Association of Hematological Laboratory Research (VHL) advised its members to adopt a basic protocol for haemoglobinopathy carrier detection and to provide genetic information with all positive results to allow health-care professionals to inform carriers about potential genetic risks. This article reports on the compliance with these recommendations and their consequences. Clinical chemists of all 106 Dutch laboratories were invited to answer a survey on patient population, diagnostic techniques used, (self-reported) knowledge, use and effect of the additional information. The average increase in diagnostic output was over 60% and the recommended basic protocol was applied by 65% of the laboratories. Over 84% of the laboratories reported to be aware of the additional recommendations and 77% to be using them. Most laboratories with limited diagnostic requests were still sending their cases to other laboratories and included the genetic information received from these laboratories in their diagnostic reports. The effect of information on subsequent 'family analysis' was estimated to be between 26 and 50%. The present study shows an increase in diagnostic potential for haemoglobinopathy over the last decade, especially in the larger cities. Low 'family testing' rates were mostly found in areas with lower carrier prevalence or associated with local reluctance to pass the information to carriers. In spite of a dramatic improvement, too many carriers are still not informed because of lack of awareness among health-care providers and more education is needed. © 2012 John Wiley & Sons Ltd.

  9. SUPERFUND TREATABILITY CLEARINGHOUSE: LABORATORY FEASIBILITY TESTING OF PROTOTYPE SOIL WASHING CONCEPTS

    EPA Science Inventory

    This draft document reports on laboratory testing of several washing solutions to decontaminate soils contaminated vith dioxins. The following extractants were evaluated; surfactant mixtures of 0.5% to 3% Adsee 799 and 0.5* to 3% Hyonic NP90 in distilled water, Freon TF with ...

  10. 10 CFR 26.153 - Using certified laboratories for testing urine specimens.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... for Substance Abuse Prevention, Substance Abuse and Mental Health Services Administration, Room 815.... 26.153 Section 26.153 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Laboratories... Workplace Drug Testing Programs [published in the Federal Register on April 11, 1988 (53 FR 11970), and as...

  11. 10 CFR 26.153 - Using certified laboratories for testing urine specimens.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... for Substance Abuse Prevention, Substance Abuse and Mental Health Services Administration, Room 815.... 26.153 Section 26.153 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Laboratories... Workplace Drug Testing Programs [published in the Federal Register on April 11, 1988 (53 FR 11970), and as...

  12. 10 CFR 26.153 - Using certified laboratories for testing urine specimens.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... for Substance Abuse Prevention, Substance Abuse and Mental Health Services Administration, Room 815.... 26.153 Section 26.153 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Laboratories... Workplace Drug Testing Programs [published in the Federal Register on April 11, 1988 (53 FR 11970), and as...

  13. 10 CFR 26.153 - Using certified laboratories for testing urine specimens.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... for Substance Abuse Prevention, Substance Abuse and Mental Health Services Administration, Room 815.... 26.153 Section 26.153 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Laboratories... Workplace Drug Testing Programs [published in the Federal Register on April 11, 1988 (53 FR 11970), and as...

  14. 10 CFR 26.153 - Using certified laboratories for testing urine specimens.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... for Substance Abuse Prevention, Substance Abuse and Mental Health Services Administration, Room 815.... 26.153 Section 26.153 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Laboratories... Workplace Drug Testing Programs [published in the Federal Register on April 11, 1988 (53 FR 11970), and as...

  15. Low Temperature Power Coating (LTPC) Phase 2 Laboratory Test Plan and Procedures for PACAF (Rev D)

    DTIC Science & Technology

    2018-03-20

    Δa*, LTPC Phase II Laboratory Test Plan and Procedures Rev D (CDRL A004) BATTELLE | 20 March 2018 | 6 Δb* and ΔE will be calculated post ...BATTELLE | CONTRACT NUMBER: FA8532-17-C-0008 (CDRL A004) LTPC Phase II Laboratory Test Plan and Procedures (Rev D) Prepared by... Test Plan and Procedures Rev D (CDRL A004) BATTELLE | 20 March 2018 | i List of Acronyms AGE Aircraft Ground Equipment ASTM American

  16. Using pathology-specific laboratory profiles in Clinical Pathology to reduce inappropriate test requesting: two completed audit cycles

    PubMed Central

    2012-01-01

    Background Systematic reviews have shown that, although well prepared, the Consensus Guidelines have failed to change clinical practice. In the healthcare district of Castelnovo né Monti (Reggio Emilia, Italy), it became necessary for the GPs and Clinical Pathologists to work together to jointly define laboratory profiles. Methods Observational study with two cycles of retrospective audit on test request forms, in a primary care setting. Objectives of the study were to develop pathology-specific laboratory profiles and to increase the number of provisional diagnoses on laboratory test request forms. A Multiprofessional Multidisciplinary Inter-hospital Work Team developed pathology-specific laboratory profiles for more effective test requesting. After 8 training sessions that used a combined strategy with multifaceted interventions, the 23 General Practitioners (GPs) in the trial district (Castelnovo nè Monti) tested the profiles; the 21 GPs in the Puianello district were the control group; all GPs in both districts participated in the trial. All laboratory tests for both healthcare districts are performed at the Laboratory located in the trial district. A baseline and a 1-year audit were performed in both districts on the GPs’ request forms. Results Seven pathology-specific laboratory profiles for outpatients were developed. In the year after the first audit cycle: 1) the number of tests requested in the trial district was distinctly lower than that in the previous year, with a decrease of about 5% (p < 0.001); 2) the provisional diagnosis on the request forms was 52.8% in the trial district and 42% in the control district (P < 0.001); 3) the decrease of the number of tests on each request form was much more marked in the trial district (8.73 vs. 10.77; p < 0.001). Conclusions The first audit cycle showed a significant decrease in the number of tests ordered only in the trial district. The combined strategy used in this study improved the

  17. Using pathology-specific laboratory profiles in clinical pathology to reduce inappropriate test requesting: two completed audit cycles.

    PubMed

    Baricchi, Roberto; Zini, Michele; Nibali, Maria Grazia; Vezzosi, Walter; Insegnante, Vincenzo; Manfuso, Clotilde; Polese, Alessandra; Costoli, Valmer; Spelti, Antonio; Formisano, Debora; Orlandini, Danilo; Nicolini, Fausto; Poli, Antonio

    2012-07-03

    Systematic reviews have shown that, although well prepared, the Consensus Guidelines have failed to change clinical practice. In the healthcare district of Castelnovo né Monti (Reggio Emilia, Italy), it became necessary for the GPs and Clinical Pathologists to work together to jointly define laboratory profiles. Observational study with two cycles of retrospective audit on test request forms, in a primary care setting. Objectives of the study were to develop pathology-specific laboratory profiles and to increase the number of provisional diagnoses on laboratory test request forms. A Multiprofessional Multidisciplinary Inter-hospital Work Team developed pathology-specific laboratory profiles for more effective test requesting. After 8 training sessions that used a combined strategy with multifaceted interventions, the 23 General Practitioners (GPs) in the trial district (Castelnovo nè Monti) tested the profiles; the 21 GPs in the Puianello district were the control group; all GPs in both districts participated in the trial. All laboratory tests for both healthcare districts are performed at the Laboratory located in the trial district. A baseline and a 1-year audit were performed in both districts on the GPs' request forms. Seven pathology-specific laboratory profiles for outpatients were developed. In the year after the first audit cycle: 1) the number of tests requested in the trial district was distinctly lower than that in the previous year, with a decrease of about 5% (p < 0.001); 2) the provisional diagnosis on the request forms was 52.8% in the trial district and 42% in the control district (P < 0.001); 3) the decrease of the number of tests on each request form was much more marked in the trial district (8.73 vs. 10.77; p < 0.001). The first audit cycle showed a significant decrease in the number of tests ordered only in the trial district. The combined strategy used in this study improved the prescriptive compliance of most of the GPs involved

  18. Mars Science Laboratory Flight Software Boot Robustness Testing Project Report

    NASA Technical Reports Server (NTRS)

    Roth, Brian

    2011-01-01

    On the surface of Mars, the Mars Science Laboratory will boot up its flight computers every morning, having charged the batteries through the night. This boot process is complicated, critical, and affected by numerous hardware states that can be difficult to test. The hardware test beds do not facilitate testing a long duration of back-to-back unmanned automated tests, and although the software simulation has provided the necessary functionality and fidelity for this boot testing, there has not been support for the full flexibility necessary for this task. Therefore to perform this testing a framework has been build around the software simulation that supports running automated tests loading a variety of starting configurations for software and hardware states. This implementation has been tested against the nominal cases to validate the methodology, and support for configuring off-nominal cases is ongoing. The implication of this testing is that the introduction of input configurations that have yet proved difficult to test may reveal boot scenarios worth higher fidelity investigation, and in other cases increase confidence in the robustness of the flight software boot process.

  19. 10 CFR 431.18 - Testing laboratories.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Technology/National Voluntary Laboratory Accreditation Program (NIST/NVLAP); or (2) A laboratory accreditation body having a mutual recognition arrangement with NIST/NVLAP; or (3) An organization classified by the Department, pursuant to § 431.19, as an accreditation body. (b) NIST/NVLAP is under the auspices...

  20. 10 CFR 431.18 - Testing laboratories.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Technology/National Voluntary Laboratory Accreditation Program (NIST/NVLAP); or (2) A laboratory accreditation body having a mutual recognition arrangement with NIST/NVLAP; or (3) An organization classified by the Department, pursuant to § 431.19, as an accreditation body. (b) NIST/NVLAP is under the auspices...

  1. 10 CFR 431.18 - Testing laboratories.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Technology/National Voluntary Laboratory Accreditation Program (NIST/NVLAP); or (2) A laboratory accreditation body having a mutual recognition arrangement with NIST/NVLAP; or (3) An organization classified by the Department, pursuant to § 431.19, as an accreditation body. (b) NIST/NVLAP is under the auspices...

  2. 10 CFR 431.18 - Testing laboratories.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Technology/National Voluntary Laboratory Accreditation Program (NIST/NVLAP); or (2) A laboratory accreditation body having a mutual recognition arrangement with NIST/NVLAP; or (3) An organization classified by the Department, pursuant to § 431.19, as an accreditation body. (b) NIST/NVLAP is under the auspices...

  3. 75 FR 75485 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-03

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Guidelines for Federal Workplace Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were... Laboratories and Instrumented Initial Testing Facilities (IITF) must meet in order to conduct drug and specimen...

  4. 75 FR 45128 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-02

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were first published in the..., ``Certification of Laboratories Engaged in Urine Drug Testing for Federal Agencies,'' sets strict standards that...

  5. Feasibility study of an orbiting laboratory for testing CSI technology

    NASA Technical Reports Server (NTRS)

    Bicos, Andrew S.; Loboda, Gregory G.

    1993-01-01

    A concept for an orbiting laboratory for testing Controls-Structures Integration (CSI) technology is described. The CSI-Star concept reflects a lower cost, higher risk approach. The concept supports demonstration and validation testing for critical CSI technologies at a cost of $20M to $26M with a 1-year reliability of approximately 0.9. The Ball Aerospace QuickStar bus is the carrier for the CSI test article. QuickStar is launched as a secondary payload on the McDonnell Douglas Delta 2. The QuickStar/Delta 2 approach is flight proven. The CSI test article is a 20 foot, 1 Hz, truss beam which is deployed from the QuickStar bus. The test article is well instrumented for quality system identification. The laboratory provides three layers of active control consisting of global vibration suppression along the truss beam, vibration isolation between the beam and instrument platforms, and vibration compensation through the use of gimbaled platforms which point lasers relative to optical sensor targets. The configuration simulates the dynamics of multi-instrument science platforms such as those of the Earth Observation System (EOS) while maintaining strong ties to astrophysics missions such as the Optical Interferometer. Uplink/downlink services and a reprogrammable computer provide flexibility for long-term investigations by members of the CSI community (NASA, DoD, academia, and industry). CSI-Star fills the gap between short-term experiments, which have been conducted primarily on the Shuttle, and future science missions which require the technology. The on-orbit maturity of CSI technology must be established to obtain acceptance by project managers and to promote injection of the technology into future science missions.

  6. Laboratory Tests

    MedlinePlus

    ... Medical Devices Radiation-Emitting Products Vaccines, Blood & Biologics Animal & Veterinary Cosmetics Tobacco Products Medical Devices Home Medical Devices Products and Medical Procedures In Vitro Diagnostics Tests Used In Clinical Care Tests Used In Clinical Care ...

  7. SRB Materials and Processes Assessment from Laboratory and Ocean Environmental Tests

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The Materials and Processes Laboratory evaluation of Solid Rocket Boosters (SRB) and Solid Rocket Motors (SRM) candidate material, both in-house and with ocean exposure tests at Panama City and Kennedy Space Center (KSC), Florida is presented. Early sample tests showed excellent seawater corrosion resistance for inconel 718 and titanium 6A1-4V alloys. Considerable corrosion and biofouling occurred with bare 2219-T87 aluminum. Subsequent tests conclusively demonstrated that epoxy coatings prevented corrosion of 2219-T87 aluminum as long as the coatings stays intact. The results and assessment of the series of ocean environmental tests that were conducted are also presented.

  8. Laboratory breeding and testing of Australorbis glabratus for molluscicidal screening

    PubMed Central

    Hopf, H. S.; Muller, R. L.

    1962-01-01

    The authors describe a technique for laboratory breeding of Australorbis glabratus, the intermediate host of Schistosoma mansoni in South America. This technique is suitable for obtaining large numbers of snails in a small space with the minimum of maintenance time and under carefully controlled conditions. Techniques are also outlined for testing molluscicides against eggs and young snails as well as against adults. It is considered that, in view of the saving in breeding time and space effected, testing against young snails has several advantages for primary screening. With no compounds tested have anomalous results been obtained. Finally, the authors report on the results obtained with a new class of molluscicidal compounds—the organo-tins—which cause snail mortality in concentrations as low as those of any of the other molluscicides tested. PMID:13961665

  9. Multi-Sensor Testing for Automated Rendezvous and Docking Sensor Testing at the Flight Robotics Laboratory

    NASA Technical Reports Server (NTRS)

    Brewster, L.; Johnston, A.; Howard, R.; Mitchell, J.; Cryan, S.

    2007-01-01

    The Exploration Systems Architecture defines missions that require rendezvous, proximity operations, and docking (RPOD) of two spacecraft both in Low Earth Orbit (LEO) and in Low Lunar Orbit (LLO). Uncrewed spacecraft must perform automated and/or autonomous rendezvous, proximity operations and docking operations (commonly known as AR&D). The crewed missions may also perform rendezvous and docking operations and may require different levels of automation and/or autonomy, and must provide the crew with relative navigation information for manual piloting. The capabilities of the RPOD sensors are critical to the success of the Exploration Program. NASA has the responsibility to determine whether the Crew Exploration Vehicle (CEV) contractor proposed relative navigation sensor suite will meet the requirements. The relatively low technology readiness level of AR&D relative navigation sensors has been carried as one of the CEV Project's top risks. The AR&D Sensor Technology Project seeks to reduce the risk by the testing and analysis of selected relative navigation sensor technologies through hardware-in-the-loop testing and simulation. These activities will provide the CEV Project information to assess the relative navigation sensors maturity as well as demonstrate test methods and capabilities. The first year of this project focused on a series of"pathfinder" testing tasks to develop the test plans, test facility requirements, trajectories, math model architecture, simulation platform, and processes that will be used to evaluate the Contractor-proposed sensors. Four candidate sensors were used in the first phase of the testing. The second phase of testing used four sensors simultaneously: two Marshall Space Flight Center (MSFC) Advanced Video Guidance Sensors (AVGS), a laser-based video sensor that uses retroreflectors attached to the target vehicle, and two commercial laser range finders. The multi-sensor testing was conducted at MSFC's Flight Robotics Laboratory (FRL

  10. Test Results From The Idaho National Laboratory Of The NASA Bi-Supported Cell Design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    C Stoots; J O'Brien; T Cable

    The Idaho National Laboratory has been researching the application of solid-oxide fuel cell technology for large-scale hydrogen production. As a result, the Idaho National Laboratory has been testing various cell designs to characterize electrolytic performance. NASA, in conjunction with the University of Toledo, has developed a new cell concept with the goals of reduced weight and high power density. This paper presents results of the INL's testing of this new solid oxide cell design as an electrolyzer. Gas composition, operating voltage, and other parameters were varied during testing. Results to date show the NASA cell to be a promising designmore » for both high power-to-weight fuel cell and electrolyzer applications.« less

  11. 10 CFR 31.11 - General license for use of byproduct material for certain in vitro clinical or laboratory testing.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... in vitro clinical or laboratory testing. 31.11 Section 31.11 Energy NUCLEAR REGULATORY COMMISSION... certain in vitro clinical or laboratory testing. (a) A general license is hereby issued to any physician, veterinarian in the practice of veterinary medicine, clinical laboratory or hospital to receive, acquire...

  12. A Laboratory-Based Evaluation of Four Rapid Point-of-Care Tests for Syphilis

    PubMed Central

    Causer, Louise M.; Kaldor, John M.; Fairley, Christopher K.; Donovan, Basil; Karapanagiotidis, Theo; Leslie, David E.; Robertson, Peter W.; McNulty, Anna M.; Anderson, David; Wand, Handan; Conway, Damian P.; Denham, Ian; Ryan, Claire; Guy, Rebecca J.

    2014-01-01

    Background Syphilis point-of-care tests may reduce morbidity and ongoing transmission by increasing the proportion of people rapidly treated. Syphilis stage and co-infection with HIV may influence test performance. We evaluated four commercially available syphilis point-of-care devices in a head-to-head comparison using sera from laboratories in Australia. Methods Point-of-care tests were evaluated using sera stored at Sydney and Melbourne laboratories. Sensitivity and specificity were calculated by standard methods, comparing point-of-care results to treponemal immunoassay (IA) reference test results. Additional analyses by clinical syphilis stage, HIV status, and non-treponemal antibody titre were performed. Non-overlapping 95% confidence intervals (CI) were considered statistically significant differences in estimates. Results In total 1203 specimens were tested (736 IA-reactive, 467 IA-nonreactive). Point-of-care test sensitivities were: Determine 97.3%(95%CI:95.8–98.3), Onsite 92.5%(90.3–94.3), DPP 89.8%(87.3–91.9) and Bioline 87.8%(85.1–90.0). Specificities were: Determine 96.4%(94.1–97.8), Onsite 92.5%(90.3–94.3), DPP 98.3%(96.5–99.2), and Bioline 98.5%(96.8–99.3). Sensitivity of the Determine test was 100% for primary and 100% for secondary syphilis. The three other tests had reduced sensitivity among primary (80.4–90.2%) compared to secondary syphilis (94.3–98.6%). No significant differences in sensitivity were observed by HIV status. Test sensitivities were significantly higher among high-RPR titre (RPR≥8) (range: 94.6–99.5%) than RPR non-reactive infections (range: 76.3–92.9%). Conclusions The Determine test had the highest sensitivity overall. All tests were most sensitive among high-RPR titre infections. Point-of-care tests have a role in syphilis control programs however in developed countries with established laboratory infrastructures, the lower sensitivities of some tests observed in primary syphilis suggest these would

  13. Design and laboratory testing of a prototype linear temperature sensor

    NASA Astrophysics Data System (ADS)

    Dube, C. M.; Nielsen, C. M.

    1982-07-01

    This report discusses the basic theory, design, and laboratory testing of a prototype linear temperature sensor (or "line sensor'), which is an instrument for measuring internal waves in the ocean. The operating principle of the line sensor consists of measuring the average resistance change of a vertically suspended wire (or coil of wire) induced by the passage of an internal wave in a thermocline. The advantage of the line sensor over conventional internal wave measurement techniques is that it is insensitive to thermal finestructure which contaminates point sensor measurements, and its output is approximately linearly proportional to the internal wave displacement. An approximately one-half scale prototype line sensor module was teste in the laboratory. The line sensor signal was linearly related to the actual fluid displacement to within 10%. Furthermore, the absolute output was well predicted (within 25%) from the theoretical model and the sensor material properties alone. Comparisons of the line sensor and a point sensor in a wavefield with superimposed turbulence (finestructure) revealed negligible distortion in the line sensor signal, while the point sensor signal was swamped by "turbulent noise'. The effects of internal wave strain were also found to be negligible.

  14. Operational evaluation of rapid diagnostic testing for Ebola Virus Disease in Guinean laboratories

    PubMed Central

    Aho, Josephine; Franklin, Kristyn; Likofata, Jacques; Kamgang, Jean Baptiste; Keita, Sakoba; Koivogui, Lamine; Magassouba, N’Faly; Martel, Lise D.; Dahourou, Anicet George

    2017-01-01

    Background Rapid Diagnostic Tests (RDTs) for Ebola Virus Disease (EVD) at the point of care have the potential to increase access and acceptability of EVD testing and the speed of patient isolation and secure burials for suspect cases. A pilot program for EVD RDTs in high risk areas of Guinea was introduced in October 2015. This paper presents concordance data between EVD RDTs and PCR testing in the field as well as an assessment of the acceptability, feasibility, and quality assurance of the RDT program. Methods and findings Concordance data were compiled from laboratory surveillance databases. The operational measures of the laboratory-based EVD RDT program were evaluated at all 34 sentinel sites in Guinea through: (1) a technical questionnaire filled by the lab technicians who performed the RDTs, (2) a checklist filled by the evaluator during the site visits, and (3) direct observation of the lab technicians performing the quality control test. Acceptability of the EVD RDT was good for technicians, patients, and families although many technicians (69.8%) expressed concern for their safety while performing the test. The feasibility of the program was good based on average technician knowledge scores (6.6 out of 8) but basic infrastructure, equipment, and supplies were lacking. There was much room for improvement in quality assurance of the program. Conclusions The implementation of new diagnostics in weak laboratory systems requires general training in quality assurance, biosafety and communication with patients in addition to specific training for the new test. Corresponding capacity building in terms of basic equipment and a long-term commitment to transfer supervision and quality improvement to national public health staff are necessary for successful implementation. PMID:29190713

  15. Operational evaluation of rapid diagnostic testing for Ebola Virus Disease in Guinean laboratories.

    PubMed

    VanSteelandt, Amanda; Aho, Josephine; Franklin, Kristyn; Likofata, Jacques; Kamgang, Jean Baptiste; Keita, Sakoba; Koivogui, Lamine; Magassouba, N'Faly; Martel, Lise D; Dahourou, Anicet George

    2017-01-01

    Rapid Diagnostic Tests (RDTs) for Ebola Virus Disease (EVD) at the point of care have the potential to increase access and acceptability of EVD testing and the speed of patient isolation and secure burials for suspect cases. A pilot program for EVD RDTs in high risk areas of Guinea was introduced in October 2015. This paper presents concordance data between EVD RDTs and PCR testing in the field as well as an assessment of the acceptability, feasibility, and quality assurance of the RDT program. Concordance data were compiled from laboratory surveillance databases. The operational measures of the laboratory-based EVD RDT program were evaluated at all 34 sentinel sites in Guinea through: (1) a technical questionnaire filled by the lab technicians who performed the RDTs, (2) a checklist filled by the evaluator during the site visits, and (3) direct observation of the lab technicians performing the quality control test. Acceptability of the EVD RDT was good for technicians, patients, and families although many technicians (69.8%) expressed concern for their safety while performing the test. The feasibility of the program was good based on average technician knowledge scores (6.6 out of 8) but basic infrastructure, equipment, and supplies were lacking. There was much room for improvement in quality assurance of the program. The implementation of new diagnostics in weak laboratory systems requires general training in quality assurance, biosafety and communication with patients in addition to specific training for the new test. Corresponding capacity building in terms of basic equipment and a long-term commitment to transfer supervision and quality improvement to national public health staff are necessary for successful implementation.

  16. 42 CFR 414.509 - Reconsideration of basis for and amount of payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... for a new clinical diagnostic laboratory test. 414.509 Section 414.509 Public Health CENTERS FOR... FOR PART B MEDICAL AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.509 Reconsideration of basis for and amount of payment for a new clinical diagnostic laboratory...

  17. Creep Laboratory manual

    NASA Astrophysics Data System (ADS)

    Osgerby, S.; Loveday, M. S.

    1992-06-01

    A manual for the NPL Creep Laboratory, a collective name given to two testing laboratories, the Uniaxial Creep Laboratory and the Advanced High Temperature Mechanical Testing Laboratory, is presented. The first laboratory is devoted to uniaxial creep testing and houses approximately 50 high sensitivity creep machines including 10 constant stress cam lever machines. The second laboratory houses a low cycle fatigue testing machine of 100 kN capacity driven by a servo-electric actuator, five machines for uniaxial tensile creep testing of engineering ceramics at temperatures up to 1600C, and an electronic creep machine. Details of the operational procedures for carrying out uniaxial creep testing are given. Calibration procedures to be followed in order to comply with the specifications laid down by British standards, and to provide traceability back to the primary standards are described.

  18. Robonaut 2 performs tests in the U.S. Laboratory

    NASA Image and Video Library

    2013-01-17

    ISS034-E-031125 (17 Jan. 2013) --- In the International Space Station's Destiny laboratory, Robonaut 2 is pictured during a round of testing for the first humanoid robot in space. Ground teams put Robonaut through its paces as they remotely commanded it to operate valves on a task board. Robonaut is a testbed for exploring new robotic capabilities in space, and its form and dexterity allow it to use the same tools and control panels as its human counterparts do aboard the station.

  19. Robonaut 2 performs tests in the U.S. Laboratory

    NASA Image and Video Library

    2013-01-17

    ISS034-E-031124 (17 Jan. 2013) --- In the International Space Station's Destiny laboratory, Robonaut 2 is pictured during a round of testing for the first humanoid robot in space. Ground teams put Robonaut through its paces as they remotely commanded it to operate valves on a task board. Robonaut is a testbed for exploring new robotic capabilities in space, and its form and dexterity allow it to use the same tools and control panels as its human counterparts do aboard the station.

  20. Acoustical Testing Laboratory Developed to Support the Low-Noise Design of Microgravity Space Flight Hardware

    NASA Technical Reports Server (NTRS)

    Cooper, Beth A.

    2001-01-01

    The NASA John H. Glenn Research Center at Lewis Field has designed and constructed an Acoustical Testing Laboratory to support the low-noise design of microgravity space flight hardware. This new laboratory will provide acoustic emissions testing and noise control services for a variety of customers, particularly for microgravity space flight hardware that must meet International Space Station limits on noise emissions. These limits have been imposed by the space station to support hearing conservation, speech communication, and safety goals as well as to prevent noise-induced vibrations that could impact microgravity research data. The Acoustical Testing Laboratory consists of a 23 by 27 by 20 ft (height) convertible hemi/anechoic chamber and separate sound-attenuating test support enclosure. Absorptive 34-in. fiberglass wedges in the test chamber provide an anechoic environment down to 100 Hz. A spring-isolated floor system affords vibration isolation above 3 Hz. These criteria, along with very low design background levels, will enable the acquisition of accurate and repeatable acoustical measurements on test articles, up to a full space station rack in size, that produce very little noise. Removable floor wedges will allow the test chamber to operate in either a hemi/anechoic or anechoic configuration, depending on the size of the test article and the specific test being conducted. The test support enclosure functions as a control room during normal operations but, alternatively, may be used as a noise-control enclosure for test articles that require the operation of noise-generating test support equipment.

  1. Viability testing of material derived from Mycobacterium tuberculosis prior to removal from a Containment Level-III Laboratory as part of a Laboratory Risk Assessment Program

    PubMed Central

    Blackwood, Kym S; Burdz, Tamara V; Turenne, Christine Y; Sharma, Meenu K; Kabani, Amin M; Wolfe, Joyce N

    2005-01-01

    Background In the field of clinical mycobacteriology, Mycobacterium tuberculosis (MTB) can be a difficult organism to manipulate due to the restrictive environment of a containment level 3 (CL3) laboratory. Tests for rapid diagnostic work involving smears and molecular methods do not require CL3 practices after the organism has been rendered non-viable. While it has been assumed that after organism deactivation these techniques can be performed outside of a CL3, no conclusive study has consistently confirmed that the organisms are noninfectious after the theoretical 'deactivation' steps. Previous studies have shown that initial steps (such as heating /chemical fixation) may not consistently kill MTB organisms. Methods An inclusive viability study (n = 226) was undertaken to determine at which point handling of culture extraction materials does not necessitate a CL3 environment. Four different laboratory protocols tested for viability included: standard DNA extractions for IS6110 fingerprinting, crude DNA preparations for PCR by boiling and mechanical lysis, protein extractions, and smear preparations. For each protocol, laboratory staff planted a proportion of the resulting material to Bactec 12B medium that was observed for growth for 8 weeks. Results Of the 208 isolates initially tested, 21 samples grew within the 8-week period. Sixteen (7.7%) of these yielded positive results for MTB that included samples of: deactivated culture resuspensions exposed to 80°C for 20 minutes, smear preparations and protein extractions. Test procedures were consequently modified and tested again (n = 18), resulting in 0% viability. Conclusions This study demonstrates that it cannot be assumed that conventional practices (i.e. smear preparation) or extraction techniques render the organism non-viable. All methodologies, new and existing, should be examined by individual laboratories to validate the safe removal of material derived from MTB to the outside of a CL3 laboratory. This

  2. Viability testing of material derived from Mycobacterium tuberculosis prior to removal from a containment level-III laboratory as part of a Laboratory Risk Assessment Program.

    PubMed

    Blackwood, Kym S; Burdz, Tamara V; Turenne, Christine Y; Sharma, Meenu K; Kabani, Amin M; Wolfe, Joyce N

    2005-01-24

    In the field of clinical mycobacteriology, Mycobacterium tuberculosis (MTB) can be a difficult organism to manipulate due to the restrictive environment of a containment level 3 (CL3) laboratory. Tests for rapid diagnostic work involving smears and molecular methods do not require CL3 practices after the organism has been rendered non-viable. While it has been assumed that after organism deactivation these techniques can be performed outside of a CL3, no conclusive study has consistently confirmed that the organisms are noninfectious after the theoretical 'deactivation' steps. Previous studies have shown that initial steps (such as heating/chemical fixation) may not consistently kill MTB organisms. An inclusive viability study (n = 226) was undertaken to determine at which point handling of culture extraction materials does not necessitate a CL3 environment. Four different laboratory protocols tested for viability included: standard DNA extractions for IS6110 fingerprinting, crude DNA preparations for PCR by boiling and mechanical lysis, protein extractions, and smear preparations. For each protocol, laboratory staff planted a proportion of the resulting material to Bactec 12B medium that was observed for growth for 8 weeks. Of the 208 isolates initially tested, 21 samples grew within the 8-week period. Sixteen (7.7%) of these yielded positive results for MTB that included samples of: deactivated culture resuspensions exposed to 80 degrees C for 20 minutes, smear preparations and protein extractions. Test procedures were consequently modified and tested again (n = 18), resulting in 0% viability. This study demonstrates that it cannot be assumed that conventional practices (i.e. smear preparation) or extraction techniques render the organism non-viable. All methodologies, new and existing, should be examined by individual laboratories to validate the safe removal of material derived from MTB to the outside of a CL3 laboratory. This process is vital to establish in

  3. Screening for Saponins Using the Blood Hemolysis Test. An Undergraduate Laboratory Experiment.

    ERIC Educational Resources Information Center

    Sotheeswaran, Subramaniam

    1988-01-01

    Describes an experiment for undergraduate chemistry laboratories involving a chemical found in plants and some sea animals. Discusses collection and identification of material, a hemolysis test, preparation of blood-coated agar plates, and application of samples. (CW)

  4. Inquiry-based laboratory investigations and student performance on standardized tests in biological science

    NASA Astrophysics Data System (ADS)

    Patke, Usha

    Achievement data from the 3rd International Mathematics and Sciences Study and Program for International Student Assessment in science have indicated that Black students from economically disadvantaged families underachieve at alarming rates in comparison to White and economically advantaged peer groups. The study site was a predominately Black, urban school district experiencing underachievement. The purpose of this correlational study was to examine the relationship between students' use of inquiry-based laboratory investigations and their performance on the Biology End of Course Test, as well as to examine the relationship while partialling out the effects of student gender. Constructivist theory formed the theoretical foundation of the study. Students' perceived levels of experience with inquiry-based laboratory investigations were measured using the Laboratory Program Variable Inventory (LPVI) survey. LPVI scores of 256 students were correlated with test scores and were examined by student gender. The Pearson correlation coefficient revealed a small direct correlation between students' experience in inquiry-based laboratory investigation classes and standardized test scores on the Biology EOCT. A partial correlational analysis indicated that the correlation remained after controlling for gender. This study may prompt a change from teacher-centered to student-centered pedagogy at the local site in order to increase academic achievement for all students. The results of this study may also influence administrators and policy makers to initiate local, state, or nationwide curricular development. A change in curriculum may promote social change as students become more competent, and more able, to succeed in life beyond secondary school.

  5. Laboratory test data on the stability of the STIS MAMAs

    NASA Technical Reports Server (NTRS)

    Joseph, Charles L.

    1997-01-01

    STIS has two MAMA detectors systems with distinctly different tube configurations. The first (designated BAND 1) has an opaque CsI photocathode deposited on the microchannel plate (MCP) providing wavelength coverage from 1150A to 1700A. The other MAMA (designated BAND 2) has a semitransparent CS2Te photocathode deposited on the faceplate in close proximity to the input of the MCP. It covers the 1650A to 3100A bandpass and serves as a backup for the short wavelength detector. Laboratory test data indicate that both of these detectors have good sensitivity, have good uniformity and provide stable response, making each capable of collecting data with a signal-to-noise ratio in excess of 100 per Space Telescope Imaging Spectrograph (STIS) optical resolution element. Over a multiyear development effort, a substantial body of laboratory test data (more than 6 GBytes spanning more than 6 years of collection) has accumulated on more than a dozen fabricated tubes. These tests even included a few destructive evaluations to examine the limitations and operating life. In addition, analyses where conducted regarding impact caused by the specified electronic tolerances and expected changes in the Hubble Space Telescope (HST) thermal environment. Perhaps the simplest test of stability is to collect a sequence of images, each with a uniform illumination, and use these individual "flat fields" to remove the pixel-to-pixel sensitivity in the other flat fields. These sequences typically spanned 3-5 weeks of time. The detectors are very stable, allowing the pixel-to-pixel sensitivity to be removed with good precision. The STIS specification for stability is 1% (sufficient for data with a S/N = 100) over a 1 week period and 2% over 30 days. All Engineering Model Units as well as Flight Detectors tested exceeded this specification.

  6. Advanced Laboratory and Field Arrays (ALFA) OWC Phase 1 Test

    DOE Data Explorer

    Bret Bosma

    2016-11-07

    Data from Phase 1 testing of a single ALFA OWC device at the O.H. Hinsdale Wave Research Laboratory (HWRL) at Oregon State University in Fall of 2016. Contains two zip files of raw data, one of project data ("array"), and a diagram of the device with dimensions. A "readme" file in the project data archive under "Docs" helps to explains the project data.

  7. Application of laboratory fungal resistance tests to solid wood and wood-plastic composite

    Treesearch

    Craig Merrill Clemons; Rebecca E. Ibach

    2003-01-01

    The fungal resistance of high density polyethylene filled with 50% wood flour was investigated using laboratory soil block tests. Modifications to standard test methods were made to increase initial moisture content, increase exposure surface area, and track moisture content, mechanical properties, and weight loss over the exposure period. Mechanical properties...

  8. The role of laboratory testing in detection and classification of chronic kidney disease: national recommendations

    PubMed Central

    Biljak, Vanja Radišić; Honović, Lorena; Matica, Jasminka; Krešić, Branka; Vojak, Sanela Šimić

    2017-01-01

    Chronic kidney disease (CKD) is a common clinical condition with significant adverse consequences for the patient and it is recognized as a significant public health problem. The role of laboratory medicine in diagnosis and management of CKD is of great importance: the diagnosis and staging are based on estimation of glomerular filtration rate (eGFR) and assessment of albuminuria (or proteinuria). Therefore, the joint working group of the Croatian society of medical biochemistry and laboratory medicine and Croatian chamber of medical biochemists for laboratory diagnostics in CKD issued this national recommendation regarding laboratory diagnostics of CKD.
Key factors for laboratories implementing the national guidelines for the diagnosis and management of CKD are:
1. Ensure good communication between laboratory professionals and clinicians, such as nephrologists or specialists in general/family medicine,
2. Ensure all patients are provided with the same availability of laboratory diagnostics,
3. Ensure creatinine assays are traceable to isotope dilution mass spectrometry (IDMS) method and have minimal bias and acceptable imprecision,
4. Select the appropriate GFR estimating formula. Recommended equation is the 2009 Chronic Kidney Disease Epidemiology Collaboration (CKD – EPI) equation,
5. In reporting the key laboratory tests (creatinine, eGFR, urine albumin-to-creatinine ratio, urine protein-to-creatinine ratio) use the appropriate reporting units,
6. Provide adequate information on limitations of creatinine measurement.
The manuscript has been organized to identify critical points in laboratory tests used in basic laboratory diagnostics of CKD and is based on the Kidney Disease: Improving Global Outcomes (KDIGO) 2012 Clinical Practice Guideline for the Evaluation and Management of Chronic Kidney Disease. PMID:28392738

  9. Moving from the laboratory to the field: Adding natural environmental conditions to toxicology testing

    EPA Science Inventory

    While laboratory toxicology tests are generally easy to perform, cost effective and readily interpreted, they have been criticized for being unrealistic. In contrast, field tests are considered realistic while producing results that are difficult to interpret and expensive. To ...

  10. Body fluid analysis: clinical utility and applicability of published studies to guide interpretation of today's laboratory testing in serous fluids.

    PubMed

    Block, Darci R; Algeciras-Schimnich, Alicia

    2013-01-01

    Requests for testing various analytes in serous fluids (e.g., pleural, peritoneal, pericardial effusions) are submitted daily to clinical laboratories. Testing of these fluids deviates from assay manufacturers' specifications, as most laboratory assays are optimized for testing blood or urine specimens. These requests add a burden to clinical laboratories, which need to validate assay performance characteristics in these fluids to exclude matrix interferences (given the different composition of body fluids) while maintaining regulatory compliance. Body fluid testing for a number of analytes has been reported in the literature; however, understanding the clinical utility of these analytes is critical because laboratories must address the analytic and clinical validation requirements, while educating clinicians on proper test utilization. In this article, we review the published data to evaluate the clinical utility of testing for numerous analytes in body fluid specimens. We also highlight the pre-analytic and analytic variables that need to be considered when reviewing published studies in body fluid testing. Finally, we provide guidance on how published studies might (or might not) guide interpretation of test results in today's clinical laboratories.

  11. Establishing benchmarks and metrics for disruptive technologies, inappropriate and obsolete tests in the clinical laboratory.

    PubMed

    Kiechle, Frederick L; Arcenas, Rodney C; Rogers, Linda C

    2014-01-01

    Benchmarks and metrics related to laboratory test utilization are based on evidence-based medical literature that may suffer from a positive publication bias. Guidelines are only as good as the data reviewed to create them. Disruptive technologies require time for appropriate use to be established before utilization review will be meaningful. Metrics include monitoring the use of obsolete tests and the inappropriate use of lab tests. Test utilization by clients in a hospital outreach program can be used to monitor the impact of new clients on lab workload. A multi-disciplinary laboratory utilization committee is the most effective tool for modifying bad habits, and reviewing and approving new tests for the lab formulary or by sending them out to a reference lab. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Reduced Clostridium difficile Tests and Laboratory-Identified Events With a Computerized Clinical Decision Support Tool and Financial Incentive.

    PubMed

    Madden, Gregory R; German Mesner, Ian; Cox, Heather L; Mathers, Amy J; Lyman, Jason A; Sifri, Costi D; Enfield, Kyle B

    2018-06-01

    We hypothesized that a computerized clinical decision support tool for Clostridium difficile testing would reduce unnecessary inpatient tests, resulting in fewer laboratory-identified events. Census-adjusted interrupted time-series analyses demonstrated significant reductions of 41% fewer tests and 31% fewer hospital-onset C. difficile infection laboratory-identified events following this intervention.Infect Control Hosp Epidemiol 2018;39:737-740.

  13. 42 CFR 493.1409 - Condition: Laboratories performing moderate complexity testing; technical consultant.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing moderate complexity testing; technical consultant. 493.1409 Section 493.1409 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION...

  14. 42 CFR 493.1409 - Condition: Laboratories performing moderate complexity testing; technical consultant.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Laboratories performing moderate complexity testing; technical consultant. 493.1409 Section 493.1409 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION...

  15. 42 CFR 493.1415 - Condition: Laboratories performing moderate complexity testing; clinical consultant.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Laboratories performing moderate complexity testing; clinical consultant. 493.1415 Section 493.1415 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION...

  16. Parachute Opening During Tests for Mars Science Laboratory

    NASA Image and Video Library

    2009-04-22

    Testing during March and April 2009 inside the world largest wind tunnel, at NASA Ames Research Center, Moffett Field, Calif., qualified the parachute for NASA next Mars rover. The parachute for NASA's Mars Science Laboratory mission, to be launched in 2011 and land on Mars in 2012, is the largest ever built to fly on an extraterrestrial mission. This image shows the qualification-test parachute beginning to open a few seconds after it was launched from a mortar into an 80-mile-per-hour (36-meter-per-second) wind. The parachute uses a configuration called disk-gap-band. It has 80 suspension lines, measures more than 50 meters (165 feet) in length, and opens to a diameter of nearly 16 meters (51 feet). Most of the orange and white fabric is nylon, though a small disk of heavier polyester is used near the vent in the apex of the canopy due to higher stresses there. http://photojournal.jpl.nasa.gov/catalog/PIA11992

  17. Parachute Opening During Tests for Mars Science Laboratory

    NASA Image and Video Library

    2009-04-22

    Testing during March and April 2009 inside the world largest wind tunnel, at NASA Ames Research Center, Moffett Field, Calif., qualified the parachute for NASA next Mars rover. The parachute for NASA's Mars Science Laboratory mission, to be launched in 2011 and land on Mars in 2012, is the largest ever built to fly on an extraterrestrial mission. This image shows the qualification-test parachute beginning to open a few seconds after it was launched from a mortar into an 80-mile-per-hour (36-meter-per-second) wind. The parachute uses a configuration called disk-gap-band. It has 80 suspension lines, measures more than 50 meters (165 feet) in length, and opens to a diameter of nearly 16 meters (51 feet). Most of the orange and white fabric is nylon, though a small disk of heavier polyester is used near the vent in the apex of the canopy due to higher stresses there. http://photojournal.jpl.nasa.gov/catalog/PIA11993

  18. Reverberation Chamber Uniformity Validation and Radiated Susceptibility Test Procedures for the NASA High Intensity Radiated Fields Laboratory

    NASA Technical Reports Server (NTRS)

    Koppen, Sandra V.; Nguyen, Truong X.; Mielnik, John J.

    2010-01-01

    The NASA Langley Research Center's High Intensity Radiated Fields Laboratory has developed a capability based on the RTCA/DO-160F Section 20 guidelines for radiated electromagnetic susceptibility testing in reverberation chambers. Phase 1 of the test procedure utilizes mode-tuned stirrer techniques and E-field probe measurements to validate chamber uniformity, determines chamber loading effects, and defines a radiated susceptibility test process. The test procedure is segmented into numbered operations that are largely software controlled. This document is intended as a laboratory test reference and includes diagrams of test setups, equipment lists, as well as test results and analysis. Phase 2 of development is discussed.

  19. Design and Laboratory Evaluation of Future Elongation and Diameter Measurements at the Advanced Test Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    K. L. Davis; D. L. Knudson; J. L. Rempe

    New materials are being considered for fuel, cladding, and structures in next generation and existing nuclear reactors. Such materials can undergo significant dimensional and physical changes during high temperature irradiations. In order to accurately predict these changes, real-time data must be obtained under prototypic irradiation conditions for model development and validation. To provide such data, researchers at the Idaho National Laboratory (INL) High Temperature Test Laboratory (HTTL) are developing several instrumented test rigs to obtain data real-time from specimens irradiated in well-controlled pressurized water reactor (PWR) coolant conditions in the Advanced Test Reactor (ATR). This paper reports the status ofmore » INL efforts to develop and evaluate prototype test rigs that rely on Linear Variable Differential Transformers (LVDTs) in laboratory settings. Although similar LVDT-based test rigs have been deployed in lower flux Materials Testing Reactors (MTRs), this effort is unique because it relies on robust LVDTs that can withstand higher temperatures and higher fluxes than often found in other MTR irradiations. Specifically, the test rigs are designed for detecting changes in length and diameter of specimens irradiated in ATR PWR loops. Once implemented, these test rigs will provide ATR users with unique capabilities that are sorely needed to obtain measurements such as elongation caused by thermal expansion and/or creep loading and diameter changes associated with fuel and cladding swelling, pellet-clad interaction, and crud buildup.« less

  20. Analytical performances of food microbiology laboratories - critical analysis of 7 years of proficiency testing results.

    PubMed

    Abdel Massih, M; Planchon, V; Polet, M; Dierick, K; Mahillon, J

    2016-02-01

    Based on the results of 19 food microbiology proficiency testing (PT) schemes, this study aimed to assess the laboratory performances, to highlight the main sources of unsatisfactory analytical results and to suggest areas of improvement. The 2009-2015 results of REQUASUD and IPH PT, involving a total of 48 laboratories, were analysed. On average, the laboratories failed to detect or enumerate foodborne pathogens in 3·0% of the tests. Thanks to a close collaboration with the PT participants, the causes of outliers could be identified in 74% of the cases. The main causes of erroneous PT results were either pre-analytical (handling of the samples, timing of analysis), analytical (unsuitable methods, confusion of samples, errors in colony counting or confirmation) or postanalytical mistakes (calculation and encoding of results). PT schemes are a privileged observation post to highlight analytical problems, which would otherwise remain unnoticed. In this perspective, this comprehensive study of PT results provides insight into the sources of systematic errors encountered during the analyses. This study draws the attention of the laboratories to the main causes of analytical errors and suggests practical solutions to avoid them, in an educational purpose. The observations support the hypothesis that regular participation to PT, when followed by feed-back and appropriate corrective actions, can play a key role in quality improvement and provide more confidence in the laboratory testing results. © 2015 The Society for Applied Microbiology.

  1. Errors in the Extra-Analytical Phases of Clinical Chemistry Laboratory Testing.

    PubMed

    Zemlin, Annalise E

    2018-04-01

    The total testing process consists of various phases from the pre-preanalytical to the post-postanalytical phase, the so-called brain-to-brain loop. With improvements in analytical techniques and efficient quality control programmes, most laboratory errors now occur in the extra-analytical phases. There has been recent interest in these errors with numerous publications highlighting their effect on service delivery, patient care and cost. This interest has led to the formation of various working groups whose mission is to develop standardized quality indicators which can be used to measure the performance of service of these phases. This will eventually lead to the development of external quality assessment schemes to monitor these phases in agreement with ISO15189:2012 recommendations. This review focuses on potential errors in the extra-analytical phases of clinical chemistry laboratory testing, some of the studies performed to assess the severity and impact of these errors and processes that are in place to address these errors. The aim of this review is to highlight the importance of these errors for the requesting clinician.

  2. Bill Kerslake Preparing a Test in the Rocket Laboratory

    NASA Image and Video Library

    1952-10-21

    William Kerslake, a combustion researcher at the National Advisory Committee for Aeronautics (NACA) Lewis Flight Propulsion Laboratory, examines the setup of a transparent rocket in a Rocket Laboratory test cell. Kerslake joined NACA Lewis the previous summer after graduating from the Case Institute of Technology with a chemistry degree. His earliest professional research concentrated on combustion instability in small rocket engines. While at Case the quiet, 250-pound Kerslake also demonstrated his athletic prowess on the wrestling team. He continued wrestling for roughly a decade afterwards while conducting his research with the NACA. Kerslake participated in Olympic competitions in Helsinki (1952), Melbourne (1956), and Rome (1960). He won 30 national championships in three different weight classes and captured the gold at the 1955 Pan American Games in Mexico City. Kerslake accomplished all this while maintaining his research career, raising a family, and paying his own expenses. As his wrestling career was winding down in the early 1960s, Kerslake’s professional career changed, as well. He was transferred to Harold Kaufman’s Electrostatic Propulsion Systems Section in the new Electromagnetic Propulsion Division. Kaufman was developing the first successful ion engine at the time, and Kerslake spent the remainder of his career working in the electric propulsion field. He was heavily involved in the two Space Electric Rocket Test (SERT) missions which demonstrated that the ion thrusters could successfully operate in space. Kerslake retired in 1985 with over 30 years of service.

  3. Standardized Laboratory Test Requirements for Hardening Equipment to Withstand Wave Impact Shock in Small High Speed Craft

    DTIC Science & Technology

    2017-02-06

    and methodology for transitioning craft acceleration data to laboratory shock test requirements are summarized and example requirements for...engineering rationale, assumptions, and methodology for transitioning craft acceleration data to laboratory shock test requirements are summarized and... Methodologies for Small High-Speed Craft Structure, Equipment, Shock Isolation Seats, and Human Performance At-Sea, 10 th Symposium on High

  4. Developing a competency framework for U.S. state food and feed testing laboratory personnel.

    PubMed

    Kaml, Craig; Weiss, Christopher C; Dezendorf, Paul; Ishida, Maria; Rice, Daniel H; Klein, Ron; Salfinger, Yvonne

    2014-01-01

    A competency-based training curriculum framework for U.S. state food and feed testing laboratories personnel is being developed by the International Food Protection Training Institute (IFPTI) and three partners. The framework will help laboratories catalog existing training courses/modules, identify training gaps, inform training curricula, and create career-spanning professional development learning paths, ensuring consistent performance expectations and increasing confidence in shared test results. Ultimately, the framework will aid laboratories in meeting the requirements of ISO/IEC 17025 (2005) international accreditation and the U.S. Food Safety Modernization Act (U.S. Public Law 111-353). In collaboration with the Association of Food and Drug Officials, the Association of Public Health Laboratories, and the Association of American Feed Control Officials, IFPTI is carrying out the project in two phases. In 2013, an expert panel of seven subject matter experts developed competency and curriculum frameworks for five professional levels (entry, mid-level, expert, supervisor/manager, and senior administration) across four competency domains (technical, communication, programmatic, and leadership) including approximately 80 competencies. In 2014 the expert panel will elicit feedback from peers and finalize the framework.

  5. FJ44 Turbofan Engine Test at NASA Glenn Research Center's Aero-Acoustic Propulsion Laboratory

    NASA Technical Reports Server (NTRS)

    Lauer, Joel T.; McAllister, Joseph; Loew, Raymond A.; Sutliff, Daniel L.; Harley, Thomas C.

    2009-01-01

    A Williams International FJ44-3A 3000-lb thrust class turbofan engine was tested in the NASA Glenn Research Center s Aero-Acoustic Propulsion Laboratory. This report presents the test set-up and documents the test conditions. Farfield directivity, in-duct unsteady pressures, duct mode data, and phased-array data were taken and are reported separately.

  6. An inter- laboratory proficiency testing exercise for rabies diagnosis in Latin America and the Caribbean

    PubMed Central

    Clavijo, Alfonso; Freire de Carvalho, Mary H.; Orciari, Lillian A.; Velasco-Villa, Andres; Ellison, James A.; Greenberg, Lauren; Yager, Pamela A.; Green, Douglas B.; Vigilato, Marco A.; Cosivi, Ottorino; Del Rio-Vilas, Victor J.

    2017-01-01

    The direct fluorescent antibody test (DFA), is performed in all rabies reference laboratories across Latin America and the Caribbean (LAC). Despite DFA being a critical capacity in the control of rabies, there is not a standardized protocol in the region. We describe the results of the first inter-laboratory proficiency exercise of national rabies laboratories in LAC countries as part of the regional efforts towards dog-maintained rabies elimination in the American region. Twenty three laboratories affiliated to the Ministries of Health and Ministries of Agriculture participated in this exercise. In addition, the laboratories completed an online questionnaire to assess laboratory practices. Answers to the online questionnaire indicated large variability in the laboratories throughput, equipment used, protocols availability, quality control standards and biosafety requirements. Our results will inform actions to improve and harmonize laboratory rabies capacities across LAC in support for the regional efforts towards elimination of dog-maintained rabies. PMID:28369139

  7. Errors in clinical laboratories or errors in laboratory medicine?

    PubMed

    Plebani, Mario

    2006-01-01

    Laboratory testing is a highly complex process and, although laboratory services are relatively safe, they are not as safe as they could or should be. Clinical laboratories have long focused their attention on quality control methods and quality assessment programs dealing with analytical aspects of testing. However, a growing body of evidence accumulated in recent decades demonstrates that quality in clinical laboratories cannot be assured by merely focusing on purely analytical aspects. The more recent surveys on errors in laboratory medicine conclude that in the delivery of laboratory testing, mistakes occur more frequently before (pre-analytical) and after (post-analytical) the test has been performed. Most errors are due to pre-analytical factors (46-68.2% of total errors), while a high error rate (18.5-47% of total errors) has also been found in the post-analytical phase. Errors due to analytical problems have been significantly reduced over time, but there is evidence that, particularly for immunoassays, interference may have a serious impact on patients. A description of the most frequent and risky pre-, intra- and post-analytical errors and advice on practical steps for measuring and reducing the risk of errors is therefore given in the present paper. Many mistakes in the Total Testing Process are called "laboratory errors", although these may be due to poor communication, action taken by others involved in the testing process (e.g., physicians, nurses and phlebotomists), or poorly designed processes, all of which are beyond the laboratory's control. Likewise, there is evidence that laboratory information is only partially utilized. A recent document from the International Organization for Standardization (ISO) recommends a new, broader definition of the term "laboratory error" and a classification of errors according to different criteria. In a modern approach to total quality, centered on patients' needs and satisfaction, the risk of errors and mistakes

  8. How well do general practitioners manage laboratory test results for patients with diabetes mellitus and cardiovascular disease?: A systematic review.

    PubMed

    McCaughey, Euan J; Li, Julie; Badrick, Tony C; Westbrook, Johanna I; Georgiou, Andrew

    2017-10-01

    To evaluate how well general practitioners (GPs) manage and respond to laboratory results for patients with diabetes mellitus (DM) and cardiovascular disease (CVD). MEDLINE, CINAHL, Embase, EBM reviews, ProQuest and Scopus. Peer-reviewed journal articles published between 2000 and 2015 that assessed GPs' management of laboratory results for patients with DM or CVD. Study design and demographics, laboratory tests and key findings relating to GP management of laboratory results were extracted from studies. Thirteen articles were included, comprising seven studies which utilized surveys, four observational studies, one cohort study and one randomized controlled trial. Findings indicate that GPs often overestimate the risk of complications associated with DM and CVD based on laboratory results and have unrealistically high expectations regarding the precision of laboratory tests. Considerable variation existed in the use of repeat testing for diagnostic confirmation and in GPs' identification of the difference between two consecutive results required to indicate a change in patient condition. GPs also often failed to initiate appropriate treatment for patients with DM and CVD based on laboratory results. Feedback to GPs about their test ordering patterns and educational messages on laboratory results improved clinical outcomes. Evidence about how well GPs manage results and its impact on patient outcomes remains weak and inconclusive. This review identified a number of areas where interventions could support GPs to improve the interpretation and management of laboratory test results, including feedback to GPs and educational messages on test result reports. © The Author 2017. Published by Oxford University Press in association with the International Society for Quality in Health Care. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  9. Quality management and accreditation in a mixed research and clinical hair testing analytical laboratory setting-a review.

    PubMed

    Fulga, Netta

    2013-06-01

    Quality management and accreditation in the analytical laboratory setting are developing rapidly and becoming the standard worldwide. Quality management refers to all the activities used by organizations to ensure product or service consistency. Accreditation is a formal recognition by an authoritative regulatory body that a laboratory is competent to perform examinations and report results. The Motherisk Drug Testing Laboratory is licensed to operate at the Hospital for Sick Children in Toronto, Ontario. The laboratory performs toxicology tests of hair and meconium samples for research and clinical purposes. Most of the samples are involved in a chain of custody cases. Establishing a quality management system and achieving accreditation became mandatory by legislation for all Ontario clinical laboratories since 2003. The Ontario Laboratory Accreditation program is based on International Organization for Standardization 15189-Medical laboratories-Particular requirements for quality and competence, an international standard that has been adopted as a national standard in Canada. The implementation of a quality management system involves management commitment, planning and staff education, documentation of the system, validation of processes, and assessment against the requirements. The maintenance of a quality management system requires control and monitoring of the entire laboratory path of workflow. The process of transformation of a research/clinical laboratory into an accredited laboratory, and the benefits of maintaining an effective quality management system, are presented in this article.

  10. Computerised pathology test order entry reduces laboratory turnaround times and influences tests ordered by hospital clinicians: a controlled before and after study

    PubMed Central

    Westbrook, J I; Georgiou, A; Dimos, A; Germanos, T

    2006-01-01

    Objective To assess the impact of a computerised pathology order entry system on laboratory turnaround times and test ordering within a teaching hospital. Methods A controlled before and after study compared test assays ordered from 11 wards two months before (n = 97 851) and after (n = 113 762) the implementation of a computerised pathology order entry system (Cerner Millennium Powerchart). Comparisons were made of laboratory turnaround times, frequency of tests ordered and specimens taken, proportions of patients having tests, average number per patient, and percentage of gentamicin and vancomycin specimens labelled as random. Results Intervention wards experienced an average decrease in turnaround of 15.5 minutes/test assay (range 73.8 to 58.3 minutes; p<0.001). Reductions were significant for prioritised and non‐prioritised tests, and for those done within and outside business hours. There was no significant change in the average number of tests (p = 0.228), or specimens per patient (p = 0.324), and no change in turnaround time for the control ward (p = 0.218). Use of structured order screens enhanced data provided to laboratories. Removing three test assays from the liver function order set resulted in significantly fewer of these tests being done. Conclusions Computerised order entry systems are an important element in achieving faster test results. These systems can influence test ordering patterns through structured order screens, manipulation of order sets, and analysis of real time data to assess the impact of such changes, not possible with paper based systems. The extent to which improvements translate into improved patient outcomes remains to be determined. A potentially limiting factor is clinicians' capacity to respond to, and make use of, faster test results. PMID:16461564

  11. Development of a Fan-Filter Unit Test Standard, LaboratoryValidations, and its Applications across Industries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Tengfang

    2006-10-20

    Lawrence Berkeley National Laboratory (LBNL) is now finalizing the Phase 2 Research and Demonstration Project on characterizing 2-foot x 4-foot (61-cm x 122-cm) fan-filter units in the market using the first-ever standard laboratory test method developed at LBNL.[1][2][3] Fan-filter units deliver re-circulated air and provide particle filtration control for clean environments. Much of the energy in cleanrooms (and minienvironments) is consumed by 2-foot x 4-foot (61-cm x 122-cm) or 4-foot x 4-foot (122-cm x 122-cm) fan-filter units that are typically located in the ceiling (25-100% coverage) of cleanroom controlled environments. Thanks to funding support by the California Energy Commission's Industrialmore » Program of the Public Interest Energy Research (PIER) Program, and significant participation from manufacturers and users of fan-filter units from around the world, LBNL has developed and performed a series of standard laboratory tests and reporting on a variety of 2-foot x 4-foot (61-cm x 122-cm) fan-filter units (FFUs). Standard laboratory testing reports have been completed and reported back to anonymous individual participants in this project. To date, such reports on standard testing of FFU performance have provided rigorous and useful data for suppliers and end users to better understand, and more importantly, to quantitatively characterize performance of FFU products under a variety of operating conditions.[1] In the course of the project, the standard laboratory method previously developed at LBNL has been under continuous evaluation and update.[2][3] Based upon the updated standard, it becomes feasible for users and suppliers to characterize and evaluate energy performance of FFUs in a consistent way.« less

  12. Improving laboratory efficiencies to scale-up HIV viral load testing.

    PubMed

    Alemnji, George; Onyebujoh, Philip; Nkengasong, John N

    2017-03-01

    Viral load measurement is a key indicator that determines patients' response to treatment and risk for disease progression. Efforts are ongoing in different countries to scale-up access to viral load testing to meet the Joint United Nations Programme on HIV and AIDS target of achieving 90% viral suppression among HIV-infected patients receiving antiretroviral therapy. However, the impact of these initiatives may be challenged by increased inefficiencies along the viral load testing spectrum. This will translate to increased costs and ineffectiveness of scale-up approaches. This review describes different parameters that could be addressed across the viral load testing spectrum aimed at improving efficiencies and utilizing test results for patient management. Though progress is being made in some countries to scale-up viral load, many others still face numerous challenges that may affect scale-up efficiencies: weak demand creation, ineffective supply chain management systems; poor specimen referral systems; inadequate data and quality management systems; and weak laboratory-clinical interface leading to diminished uptake of test results. In scaling up access to viral load testing, there should be a renewed focus to address efficiencies across the entire spectrum, including factors related to access, uptake, and impact of test results.

  13. An experimental test of an extended discretion approach for high school biology laboratory investigations

    NASA Astrophysics Data System (ADS)

    Leonard, William H.; Cavana, Gordon R.; Lowery, Lawrence F.

    Discretion-the exercise of independent judgment-was observed to be lacking in most commercially available laboratory investigations for high school biology. An Extended Discretion (ED) laboratory approach was developed and tested experimentally against the BSCS Green Version laboratory program, using ten classes of 10th-grade biology in a suburban California high school. Five teachers were each assigned one experimental and one control group. The primary differences between the two approaches were that the BSCS was more prescriptive and directive than the ED approach and the ED approach increased discretionary demands upon the student over the school year. A treatment verification procedure showed statistically significant differences between the two approaches. The hypothesis under test was that when high school biology students are taught laboratory concepts under comparatively high discretionary demands, they would perform as well as or better than a similar group of students taught with BSCS Green Version investigations. A second hypothesis was that teachers would prefer to use the ED approach over the BSCS approach for their future classes. A t analysis between experimental and control groups for each teacher was employed. There were significant differences in favor of the ED group on laboratory report scores for three teachers and no differences for two teachers. There were significant differences in favor of the ED group on laboratory concepts quiz scores for three teachers, no differences for one teacher, and significant differences in favor of the BSCS group for only one teacher. A t analysis of teacher evaluation of the two approaches showed a significant teacher preference overall for the ED approach. Both experimental hypotheses were accepted. The ED approach was observed to be difficult for students at first, but it was found to be a workable and productive means of teaching laboratory concepts in biology which also required extensive use of individual

  14. Comparative analytical costs of central laboratory glucose and bedside glucose testing: a College of American Pathologists Q-Probes study.

    PubMed

    Howanitz, Peter J; Jones, Bruce A

    2004-07-01

    One of the major attributes of laboratory testing is cost. Although fully automated central laboratory glucose testing and semiautomated bedside glucose testing (BGT) are performed at most institutions, rigorous determinations of interinstitutional comparative costs have not been performed. To compare interinstitutional analytical costs of central laboratory glucose testing and BGT and to provide suggestions for improvement. Participants completed a demographic form about their institutional glucose monitoring practices. They also collected information about the costs of central laboratory glucose testing, BGT at a high-volume testing site, and BGT at a low-volume testing site, including specified cost variables for labor, reagents, and instruments. A total of 445 institutions enrolled in the College of American Pathologists Q-Probes program. Median cost per glucose test at 3 testing sites. The median (10th-90th percentile range) costs per glucose test were 1.18 dollars (5.59 dollars-0.36 dollars), 1.96 dollars (9.51 dollars-0.77 dollars), and 4.66 dollars (27.54 dollars-1.02 dollars) for central laboratory, high-volume BGT sites, and low-volume BGT sites, respectively. The largest percentages of the cost per test were for labor (59.3%, 72.7%, and 85.8%), followed by supplies (27.2%, 27.3%, and 13.4%) and equipment (2.1%, 0.0%, and 0.0%) for the 3 sites, respectively. The median number of patient specimens per month at the high-volume BGT sites was 625 compared to 30 at the low-volume BGT sites. Most participants did not include labor, instrument maintenance, competency assessment, or oversight in their BGT estimated costs until required to do so for the study. Analytical costs per glucose test were lower for central laboratory glucose testing than for BGT, which, in turn, was highly variable and dependent on volume. Data that would be used for financial justification for BGT were widely aberrant and in need of improvement.

  15. 42 CFR 414.509 - Reconsideration of basis for and amount of payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) or § 414.509(a)(3) that the basis for payment for a new test will be gapfilling, CMS posts interim... for a new clinical diagnostic laboratory test. 414.509 Section 414.509 Public Health CENTERS FOR... FOR PART B MEDICAL AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests...

  16. The Boulby Geoscience Project Underground Research Laboratory: Initial Results of a Rock Mechanics Laboratory Testing Programme

    NASA Astrophysics Data System (ADS)

    Brain, M. J.; Petley, D. N.; Rosser, N.; Lim, M.; Sapsford, M.; Barlow, J.; Norman, E.; Williams, A.; Pybus, D.

    2009-12-01

    The Boulby Mine, which is situated on the northeast coast of England, is a major source of potash, primarily for use as a fertiliser, with a secondary product of rock salt (halite), used in highway deicing. The deposits are part of the Zechstein formation and are found at depths of between c.1100 and 1135 m below sea level. The evaporite sequence also contains a range of further lithologies, including anhydrite, dolomite and a mixed evaporate deposit. From a scientific perspective the dry, uncontaminated nature of the deposits, the range of lithologies present and the high stress conditions at the mine provide a unique opportunity to observe rock deformation in situ in varying geological and stress environments. To this end the Boulby Geoscience Project was established to examine the feasibility of developing an underground research laboratory at the mine. Information regarding the mechanical properties of the strata at the Boulby Mine is required to develop our understanding of the strength and deformation behaviour of the rock over differing timescales in response to variations in the magnitude and duration of applied stresses. As such data are currently limited, we have developed a laboratory testing programme that examines the behaviour of the deposits during the application of differential compressive stresses. We present the initial results of this testing programme here. Experiments have been carried out using a high pressure Virtual Infinite Strain (VIS) triaxial apparatus (250 kN maximum axial load; 64 MPa maximum cell pressure) manufactured by GDS Instruments. Conventional compression tests under uniaxial and triaxial conditions have been undertaken to determine the effects of axial stress application rate, axial strain rate and confining pressure on behaviour and failure mechanisms. The experimental programme also includes advanced testing into time-dependent creep behaviour under constant deviatoric stress; the effects of variations in temperature and

  17. Using fee-for-service testing to generate revenue for the 21st century public health laboratory.

    PubMed

    Loring, Carol; Neil, R Brock; Gillim-Ross, Laura; Bashore, Matthew; Shah, Sandip

    2013-01-01

    The decrease in appropriations for state public health laboratories (SPHLs) has become a major concern as tax revenues and, subsequently, state and federal funding, have decreased. These reductions have forced SPHLs to pursue revenue-generating opportunities to support their work. We describe the current state of funding in a sampling of SPHLs and the challenges these laboratories face as they implement or expand fee-for-service testing. We conducted surveys of SPHLs to collect data concerning laboratory funding sources, test menus, fee-for-service testing, and challenges to implementing fee-for-service testing. Most SPHLS receive funding through three revenue sources: state appropriation, federal funding, and fee-for-service testing (cash funds). Among SPHLs, state appropriations ranged from $0 to more than $6 per capita, federal funding ranged from $0.10 to $5 per capita, and revenue from fee-for-service testing ranged from $0 to $4 per capita. The tests commonly performed on a fee-for-service basis included assays for sexually transmitted diseases, mycobacterial cultures, newborn screening, and water testing. We found that restrictive legislation, staffing shortages, inadequate software for billing fee-for-service testing, and regulations on how SPHLs use their generated revenue are impediments to implementing fee-for-service testing. Some SPHLs are considering implementing or expanding fee-for-service testing as a way to recapture funds lost as a result of state and federal budget cuts. This analysis revealed many of the obstacles to implementing fee-for-service testing in SPHLs and the potential impact on SPHLs of continued decreases in funding.

  18. 42 CFR 414.509 - Reconsideration of basis for and amount of payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) or § 414.509(a)(3) that the basis for payment for a new test will be gapfilling, CMS posts interim... for a new clinical diagnostic laboratory test. 414.509 Section 414.509 Public Health CENTERS FOR... Laboratory Tests § 414.509 Reconsideration of basis for and amount of payment for a new clinical diagnostic...

  19. Radiation Testing at Sandia National Laboratories: Sandia – JPL Collaboration for Europa Lander

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hattar, Khalid Mikhiel; Olszewska-Wasiolek, Maryla Aleksandra

    Sandia National Laboratories (SNL) is assisting Jet Propulsion Laboratory in undertaking feasibility studies and performance assessments for the Planetary Protection aspect of the Europa Lander mission. The specific areas of interest for this project are described by task number. This white paper presents the evaluation results for Task 2, Radiation Testing, which was stated as follows: Survey SNL facilities and capabilities for simulating the Europan radiation environment and assess suitability for: A. Testing batteries, electronics, and other component and subsystems B. Exposing biological organisms to assess their survivability metrics. The radiation environment the Europa Lander will encounter on route andmore » in orbit upon arrival at its destination consists primarily of charged particles, energetic protons and electrons with the energies up to 1 GeV. The charged particle environments can be simulated using the accelerators at the Ion Beam Laboratory. The Gamma Irradiation Facility and its annex, the Low Dose Rate Irradiation Facility, offer irradiations using Co-60 gamma sources (1.17 and 1.33 MeV), as well as Cs-137 gamma (0.661 MeV) AmBe neutron (0-10 MeV) sources.« less

  20. Laboratory tests of short intense envelope solitons

    NASA Astrophysics Data System (ADS)

    Slunyaev, A.; Clauss, G. F.; Klein, M.; Onorato, M.

    2012-04-01

    Stability of short intense nonlinear wave groups propagating over deep water is tested in laboratory runs which are performed in the facility of the Technical University of Berlin. The strongly nonlinear simulation of quasi-steady nonlinear wave groups within the framework of the Euler equations is used to generate the surface elevation time series at a border of the water tank. Besides, the exact analytic solution of the nonlinear Schrodinger equation is used for this purpose. The time series is then transformed to a wave maker signal with use of a designed transfer algorithm. Wave group propagation along the tank was recorded by 4 distant gauges and by an array of 6 densely situated gauges. This setup allows to consider the wave evolution from 10 to 85 m from the wave maker, and to obtain the wave envelope shape directly from the instrumental data. In the experiments wave groups were characterized by the steepness values up to kAcr < 0.32 and kAtr < 0.24, where k is the mean wavenumber, Acr is the crest amplitude, and Atr is the trough amplitude; and the maximum local wave slope was up to 0.34. Wave breaking phenomenon was not observed in the experiments. Different mean wave numbers and wave groups of different intensities were considered. In some cases the wave groups exhibit noticeable radiation in the course of propagation, though the groups are not dispersed fully. The effect of finite water depth is found to be significant on the wave group stability. Intense wave groups have shorter time of adjustment, what in some sense may help them to manifest their individuality clearer. The experimental tests confirm recent numerical simulations of fully nonlinear equations, where very steep stable single and interacting nonlinear wave groups were reported [1-3]. The quasi-stationary wave groups observed in numerical and laboratory experiments are strongly nonlinear analogues of the nonlinear Schrodinger envelope solitons. The results emphasize the importance of long