Sample records for lacrimal apparatus

  1. Outcomes of malignant tumors of the lacrimal apparatus: the University of Texas MD Anderson Cancer Center experience.

    PubMed

    Skinner, Heath D; Garden, Adam S; Rosenthal, David I; Ang, K Kian; Morrison, William H; Esmaeli, Bita; Pinnix, Chelsea C; Frank, Steven J

    2011-06-15

    Malignant epithelial neoplasms of the lacrimal apparatus are rare and are typically treated with surgery and occasionally adjuvant radiation therapy (RT). The purpose of this study was to assess treatment outcomes by type of surgery (orbital exenteration vs eye-sparing surgery) and clarify the role of adjuvant RT for this rare disease. Forty-six patients with malignant epithelial neoplasms of the lacrimal apparatus were treated at a single institution from 1945 through 2008. Twenty-seven patients (59%) were treated with orbital exenteration and 19 (41%) with eye-sparing surgery; 64% of the orbital exenteration group and 83% of the eye-sparing surgery group also received adjuvant RT (median dose, 60 grays). Median follow-up time for all patients was 38 months (range, 3-460 months). For the orbital exenteration and eye-sparing surgery groups, the 5-year overall survival (OS) rates were 59% and 62%, and the 5-year disease-free survival (DFS) rates were 49% and 39%, respectively (P = .56, P = .35). Tumor status (T1-2 vs T3-4) was associated with OS (P = .02), and tumor size (<3.5 vs >3.5 cm) with DFS (P = .015). Median time to locoregional recurrence was 85 months for orbital exenteration, and 123 months for eye-sparing surgery. All patients who did not receive RT experienced local recurrence, and RT extended time to locoregional recurrence (median 460 vs 30 months, P = .009). Seven grade ≥3 complications were experienced after adjuvant RT. For appropriately selected patients, an eye-sparing surgery for lacrimal apparatus tumors can achieve similar survival outcomes to those in patients treated with an orbital exenteration. Adjuvant RT should be considered for all patients presenting with these rare tumors. Copyright © 2011 American Cancer Society.

  2. [High resolution functional magnetic resonance tomography with Gd-DTPA eyedrops in diagnosis of lacrimal apparatus diseases].

    PubMed

    Hoffmann, K T; Anders, N; Hosten, N; Holschbach, A; Walkow, T; Sörensen, R; Hartmann, C; Felix, R

    1998-08-01

    Both dacryocystography and dacryoscintigraphy are well established in the evaluation of stenoses of the lacrimal drainage system. They provide limited information about the ductal anatomy itself and about periductal structures. MR imaging was evaluated for its capability to directly visualize the lacrimal drainage system in detail and simultaneously provide functional characterization of dacryostenosis. Twenty-seven lacrimal drainage systems of 23 patients suffering from epiphora were examined in an MR unit before and after conjunctival and intravenous application of Gd-DTPA using a surface coil. Dacryostenosis was found in 23 of 27 lacrimal systems. Stenoses were localized to the canalicular (n = 3), saccular (n = 8), and ductal (n = 12) level, and were classified as stenosis or occlusion. MR imaging with conjunctival contrast application allows within one examination both detailed morphological and functional assessment of the lacrimal drainage system with depiction of surrounding structures. Limitations arise mainly from demands on technical and patient-related preconditions.

  3. Morphological Features of the Porcine Lacrimal Gland and Its Compatibility for Human Lacrimal Gland Xenografting

    PubMed Central

    Gaffling, Simone; Asano, Nagayoshi; Hampel, Ulrike; Garreis, Fabian; Hornegger, Joachim; Paulsen, Friedrich

    2013-01-01

    In this study, we present first data concerning the anatomical structure, blood supply and location of the lacrimal gland of the pig. Our data indicate that the porcine lacrimal gland may serve as a potential xenograft candidate in humans or as an animal model for engineering of a bioartificial lacrimal gland tissue construct for clinical application. For this purpose, we used different macroscopic preparation techniques and digital reconstruction of the histological gland morphology to gain new insights and important information concerning the feasibility of a lacrimal gland transplantation from pig to humans in general. Our results show that the lacrimal gland of the pig reveals a lot of morphological similarities to the analogous human lacrimal gland and thus might be regarded as a xenograft in the future. This is true for a similar anatomical location within the orbit as well as for the feeding artery supply to the organ. Functional differences concerning the composition of the tear fluid, due to a different secretory unit distribution within the gland tissue will, however, be a challenge in future investigations. PMID:24069265

  4. Morphological features of the porcine lacrimal gland and its compatibility for human lacrimal gland xenografting.

    PubMed

    Henker, Robert; Scholz, Michael; Gaffling, Simone; Asano, Nagayoshi; Hampel, Ulrike; Garreis, Fabian; Hornegger, Joachim; Paulsen, Friedrich

    2013-01-01

    In this study, we present first data concerning the anatomical structure, blood supply and location of the lacrimal gland of the pig. Our data indicate that the porcine lacrimal gland may serve as a potential xenograft candidate in humans or as an animal model for engineering of a bioartificial lacrimal gland tissue construct for clinical application. For this purpose, we used different macroscopic preparation techniques and digital reconstruction of the histological gland morphology to gain new insights and important information concerning the feasibility of a lacrimal gland transplantation from pig to humans in general. Our results show that the lacrimal gland of the pig reveals a lot of morphological similarities to the analogous human lacrimal gland and thus might be regarded as a xenograft in the future. This is true for a similar anatomical location within the orbit as well as for the feeding artery supply to the organ. Functional differences concerning the composition of the tear fluid, due to a different secretory unit distribution within the gland tissue will, however, be a challenge in future investigations.

  5. Cytokeratin expression in mouse lacrimal gland germ epithelium.

    PubMed

    Hirayama, Masatoshi; Liu, Ying; Kawakita, Tetsuya; Shimmura, Shigeto; Tsubota, Kazuo

    2016-05-01

    The lacrimal gland secretes tear fluids that protect the ocular surface epithelium, and its dysfunction leads to dry eye disease (DED). The functional restoration of the lacrimal gland by engraftment of a bioengineered lacrimal gland using lacrimal gland germ epithelial cells has been proposed to cure DED in mice. Here, we investigate the expression profile of cytokeratins in the lacrimal gland germ epithelium to clarify their unique characteristics. We performed quantitative polymerase chain reaction (Q-PCR) and immunohistochemistry (IHC) analysis to clarify the expression profile of cytokeratin in the lacrimal gland germ epithelium. The mRNA expression of keratin (KRT) 5, KRT8, KRT14, KRT15, and KRT18 in the lacrimal gland germ epithelium was increased compared with that in mouse embryonic stem cells and the lacrimal gland germ mesenchyme, as analyzed by Q-PCR. The expression level of KRT15 increased in the transition from stem cells to lacrimal gland germ epithelium, then decreased as the lacrimal gland matured. IHC revealed that the expression set of these cytokeratins in the lacrimal gland germ epithelium was different from that in the adult lacrimal gland. The expression of KRT15 was observed in the lacrimal gland germ epithelium, and it segmentalized into some of the basal cells in the intercanulated duct in mature gland. We determined the expression profile of cytokeratins in the lacrimal gland epithelium, and identified KRT15 as a candidate unique cellular marker for the lacrimal gland germ epithelium. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. [Papilloma of the lacrimal sac].

    PubMed

    Burduk, Paweł K; Seredyka-Burduk, Małgorzata; Kaźmierczak, Wojciech; Dalke, Krzysztof; Marszałek, Andrzej

    2013-01-01

    The benign lesions of the lacrimal sac are very rare. The most typical epithelial tumor is squamous papilloma. This tumors often present with symptoms of dacryostenosis and dacriocystitis. Human papillomavirus (HPV) infection is known to be causative agent in the development of epithelial tumor. Lacrimal sac tumors could transform to malignant neoplasms, especially if they are developed of coexisting HPV infection. We present a patient with a squamous papilloma of the lacrimal sac and discussed the method of treatment. The patient was suffered from epiphora and recurrent dacriocystitis. An endoscopic surgery with dacriocystorhinostomy and local resection of the tumor could be an effective method of choice. The usage of a shaver for wide removal of the lacrimal sac wall is recommended to prevent local recurrence. The histopathology examination showed squamous papilloma. The patient is free of the disease over 8 months of follow up. Primary lacrimal sac papilloma require long term follow up for recurrence or malignant transformation. HPV infection could be associated with the development of lacrimal sac papillomas. Copyright © 2012 Polish Otorhinolaryngology - Head and Neck Surgery Society. Published by Elsevier Urban & Partner Sp. z.o.o. All rights reserved.

  7. [Comparative ultrastructural study of parotid gland, lacrimal gland and pituitary gland between miniature pig and mouse].

    PubMed

    Yan, Xing; Hai, Bo; Sun, Yi-lin; Zhang, Chun-mei; Wang, Song-ling

    2009-02-01

    To study the ultrastructure of parotid glands, lacrimal glands and pituitary glands between miniature pig and mouse. Five adult miniature pigs and 5 mice were studied. Ultrastructure of their parotid glands, lacrimal glands, and pituitary glands was observed. The secretary granules in acinar cell of miniature pig parotid glands showed higher density and more aequalis than those of mice. The cell apparatus in acinar cell of mouse parotid glands were more plentiful than those of miniature pigs. The secretary granules on blood vessel wall were richer in parotid gland of miniature pigs compared with mouse parotid gland. Lacrimal gland had the similar ultrastructure to parotid gland in these two animals. Many blood vessel antrum were found in pituitary glands of these two animals. Compared with mouse parotid glands, there are more secretary granules in acinar cells and vascular endothelial cells in miniature pig parotid glands, which might enter blood stream and have function of endocrine secretion.

  8. Bioengineered Lacrimal Gland Organ Regeneration in Vivo

    PubMed Central

    Hirayama, Masatoshi; Tsubota, Kazuo; Tsuji, Takashi

    2015-01-01

    The lacrimal gland plays an important role in maintaining a homeostatic environment for healthy ocular surfaces via tear secretion. Dry eye disease, which is caused by lacrimal gland dysfunction, is one of the most prevalent eye disorders and causes ocular discomfort, significant visual disturbances, and a reduced quality of life. Current therapies for dry eye disease, including artificial tear eye drops, are transient and palliative. The lacrimal gland, which consists of acini, ducts, and myoepithelial cells, develops from its organ germ via reciprocal epithelial-mesenchymal interactions during embryogenesis. Lacrimal tissue stem cells have been identified for use in regenerative therapeutic approaches aimed at restoring lacrimal gland functions. Fully functional organ replacement, such as for tooth and hair follicles, has also been developed via a novel three-dimensional stem cell manipulation, designated the Organ Germ Method, as a next-generation regenerative medicine. Recently, we successfully developed fully functional bioengineered lacrimal gland replacements after transplanting a bioengineered organ germ using this method. This study represented a significant advance in potential lacrimal gland organ replacement as a novel regenerative therapy for dry eye disease. In this review, we will summarize recent progress in lacrimal regeneration research and the development of bioengineered lacrimal gland organ replacement therapy. PMID:26264034

  9. EFFECT OF INFLAMMATION ON LACRIMAL GLAND FUNCTION

    PubMed Central

    Zoukhri, Driss

    2005-01-01

    The lacrimal gland is the main contributor to the aqueous layer of the tear film. It secretes proteins, electrolytes and water, which helps to nourish and protect the ocular surface. Lacrimal gland secretion is primarily under neural control, which is achieved through a neural reflex arc. Stimuli to the ocular surface activate afferent sensory nerves in the cornea and conjunctiva. This in turn activates efferent parasympathetic and sympathetic nerves in the lacrimal gland to stimulate secretion. Sex steroid hormones are also important regulators of lacrimal gland functions. A decrease or lack of lacrimal gland secretion is the leading cause of aqueous tear deficient dry eye syndrome (DES). It has been suggested that DES is an inflammatory disorder that affects the ocular surface and the lacrimal gland. In several pathological instances, the lacrimal gland can become a target of the immune system and show signs of inflammation. This can result from autoimmune diseases (Sjögren's syndrome), organ transplantation (graft versus host disease), or simply as a result of aging. The hallmarks of lacrimal gland inflammation are the presence of focal lymphocytic infiltrates and increased production of proinflammatory cytokines. The mechanisms leading to lacrimal gland dysfunction are still poorly understood. Apoptosis, production of autoantibodies, hormonal imbalance, alterations in signaling molecules, neural dysfunction, and increased levels of proinflammatory cytokines have been proposed as possible mediators of lacrimal gland insufficiency in disease states. PMID:16309672

  10. Isotretinoin in lacrimal gland fluid and tears.

    PubMed

    Rismondo, V; Ubels, J L

    1987-03-01

    Isotretinoin (13-cis-retinoic acid) is used in the treatment of severe cystic acne. Adverse ocular reactions, including blepharoconjunctivitis and dry eye symptoms, are frequent side effects of this drug. Our previous observation that retinol is present in tears and lacrimal gland fluid suggests that isotretinoin may also be secreted by the lacrimal gland. Rabbits were treated with isotretinoin, and lacrimal gland fluid was collected from the cannulated lacrimal gland duct. Tears were collected from patients who were being treated with isotretinoin. Lacrimal gland fluid and tears were analyzed by reverse-phase high-pressure liquid chromatography and a peak eluted from each sample, which was identified as isotretinoin. We conclude that the lacrimal gland is able to secrete isotretinoin in addition to retinol and that, in animals and patients treated systemically with isotretinoin, the ocular surface is exposed to the drug via the tear film.

  11. Morphogenesis of the human excretory lacrimal system

    PubMed Central

    de la Cuadra-Blanco, C; Peces-Peña, M D; Jáñez-Escalada, L; Mérida-Velasco, J R

    2006-01-01

    The aim of this study was to determine the principal developmental stages in the formation of the excretory lacrimal system in humans and to establish its morphogenetic period. The study was performed using light microscopy on serial sections of 51 human specimens: 33 embryos and 18 fetuses ranging from 8 to 137 mm crown–rump length (CR; 5–16 weeks of development). Three stages were identified in the morphogenesis of the excretory lacrimal system: (1) the formative stage of the lacrimal lamina (Carnegie stages 16–18); (2) the formative stage of the lacrimal cord (Carnegie stages 19–23); and (3) the maturative stage of the excretory lacrimal system, from the 9th week of development onward. A three-dimensional reconstruction of the excretory lacrimal system was performed from serial sections of an embryo at the end of the embryonic period (27 mm CR). PMID:16879594

  12. [Eye-associated lymphoid tissue (EALT) is continuously spread throughout the ocular surface from the lacrimal gland to the lacrimal drainage system].

    PubMed

    Knop, E; Knop, N

    2003-11-01

    Components of the mucosal immune system (MALT) have been identified in the conjunctiva (as CALT) and the lacrimal drainage system (as LDALT). Their structural and functional relation with the established immune protection by the lacrimal gland is unclear. Macroscopically normal and complete tissues of the conjunctiva, lacrimal drainage system and lacrimal gland from human body donors were investigated by analysis of translucent whole mounts, and using histology, immunohistology as well as scanning and transmission electron microscopy. A typical diffuse lymphoid tissue, composed of effector cells of the immune system (T-lymphocytes and IgA producing plasma cells) under an epithelium that contains the IgA transporter SC, is not isolated in the conjunctiva and lacrimal drainage system. It is anatomically continuous from the lacrimal gland along its excretory ducts into the conjunctiva and from there via the lacrimal canaliculi into the lacrimal drainage system. Lymphoid follicles occur in a majority (about 60%) and with bilateral symmetry. The topography of CALT corresponds to the position of the cornea in the closed eye. These results show that the MALT of the lacrimal gland, conjunctiva and lacrimal drainage system constitute an anatomical and functional unit for immune protection of the ocular surface. Therefore it should be integrated as an "eye-associated lymphoid tissue" (EALT) into the MALT system of the body. EALT can detect ocular surface antigens by the lymphoid follicles and can supply other organs and the ocular surface including the lacrimal gland with specific effector cells via the regulated recirculation of lymphoid cells.

  13. Pleomorphic adenoma of a deep orbital ectopic lacrimal gland.

    PubMed

    Misra, Somen; Bhandari, Akshay; Misra, Neeta; Gogri, Pratik; Mahajan, Shruti

    2016-10-01

    Ectopic lacrimal gland, being one of the choristomas, is comprised of lacrimal gland tissue outside the lacrimal gland fossa in the fronto-lateral part of the orbital roof. Ectopic lacrimal gland is a rare condition where the gland may be found in the orbit, eyelids, ocular adnexa or within the globe. Neoplastic transformation of such tissue may occur. A sixty-two-year old male patient presented with right eye proptosis and slight nasal displacement of the globe. Computerized tomography scan revealed a well-defined hypodense lesion of size 19 x 18 x 20 mm supero-lateral to lateral rectus muscle, with mild proptosis and thinning of the right lateral orbital wall. Excisional biopsy was performed through a lateral orbitotomy approach. A well circumscribed globular mass was removed from the right orbit, well behind the fossa for the lacrimal gland in the retrobulbar space. Histopathology was suggestive of pleomorphic adenoma of lacrimal gland. Pleomorphic adenoma is an epithelial tumor of the lacrimal gland which is extremely rare from an ectopic lacrimal gland and only few cases have been reported in literature till date.

  14. Characterization of cultivated murine lacrimal gland epithelial cells

    PubMed Central

    Kobayashi, Shinya; Kawashima, Motoko; Okada, Naoko; Mishima, Kenji; Saito, Ichiro; Ito, Masataka; Shimmura, Shigeto; Tsubota, Kazuo

    2012-01-01

    Purpose To date, mouse lacrimal gland epithelial cells have been cultured successfully but only in cases involving newborn mouse lacrimal glands. In this work, we attempted to cultivate and characterize adult mouse lacrimal gland epithelial cells. Methods Lacrimal glands were removed from newborn mice (C57B/6) and isolated lacrimal gland epithelial cells were seeded onto tissue culture treated or low adherent culture dishes in Cnt-07 culture medium with or without cholera toxin. Cultivated cells were characterized by immunostaining with pan-cytokeratin, α-smooth muscle actin, and lactoferrin antibodies. Lacrimal gland cells from 7-week-old green fluorescent protein (GFP) and non-GFP (C57B/6) mice were mixed and seeded onto uncoated dishes to assess sphere-forming efficiency. Cells were also seeded onto 3T3 cell feeder layers to assess colony forming efficiency. Results Lacrimal gland epithelial cells were selectively cultured with cholera toxin, and cell type was verified by pan-cytokeratin and α-smooth muscle actin immunostaining. Sphere formation from single cells of adult mice was observed using specific medium and low adherent culture dishes. These cells could also undergo colony formation on 3T3 feeder cells. Conclusions Adult mouse lacrimal gland epithelial cells were successfully cultivated in cholera toxin-containing medium, and were observed to form spheres from single cells. PMID:22665974

  15. Lacrimal Gland Radiosensitivity in Uveal Melanoma Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muller, Karin; Nowak, Peter J.C.M.; Naus, Nicole

    2009-06-01

    Purpose: To find a dose-volume effect for inhomogeneous irradiated lacrimal glands. Methods and Materials: Between 1999 and 2006, 72 patients (42 men and 30 women) were treated with fractionated stereotactic radiotherapy in a prospective, nonrandomized clinical trial (median follow-up, 32 months). A total dose of 50 Gy was given on 5 consecutive days. The mean of all Schirmer test results obtained {>=}6 months after treatment was correlated with the radiation dose delivered to the lacrimal gland. Also, the appearance of dry eye syndrome (DES) was related to the lacrimal gland dose distribution. Results: Of the 72 patients, 17 developed amore » late Schirmer value <10 mm; 9 patients developed DES. A statistically significant relationship was found between the received median dose in the lacrimal gland vs. reduced tear production (p = 0.000) and vs. the appearance of DES (p = 0.003), respectively. A median dose of 7 Gy/fraction to the lacrimal gland caused a 50% risk of low Schirmer results. A median dose of 10 Gy resulted in a 50% probability of DES. Conclusion: We found a clear dose-volume relationship for irradiated lacrimal glands with regard to reduced tear production and the appearance of DES.« less

  16. Measurement of Lacrimal Sac Fossa Using Orbital Computed Tomography.

    PubMed

    Kang, Dongwan; Park, Jinhwan; Na, Jaehoon; Lee, Hwa; Baek, Sehyun

    2017-01-01

    To evaluate the clinical usefulness of measuring the lacrimal sac fossa length using orbital computed tomography in normal Koreans. The authors retrospectively evaluated 140 patients (70 males and 70 females) who underwent orbital computed tomography at Guro Hospital and who had no history of orbital disease or orbital trauma. Computed tomography scans of the right orbit, including the proportion of the lacrimal bone and maxillary bone that comprise the lacrimal sac fossa, were evaluated at 3 different axial planes (lower, middle, and upper levels). Additionally, the mid-point thickness and maximum thickness of the maxillary bone were measured. Finally, the authors also evaluated the relationship between nasal bone height and maxillary bone thickness in the lacrimal sac fossa. Maxillary bone thickness in the lacrimal sac fossa was thicker in males than in females at mid-point thickness and maximum thickness (P < 0.05). However, there was no significant difference in the size of the lacrimal sac fossa and the proportion of the maxillary bone between males and females.In comparisons between maxillary cross-sections, bone thickness was greater toward the upper level of the lacrimal sac fossa (P = 0.008), and the proportion of the maxillary bone was also greater (P = 0.006).Aging had a significant positive correlation with maxillary bone thickness at all 3 axial planes (P < 0.05), but there was no relationship between age and maxillary bone proportion. Nasal bone height and maxillary bone thickness were also not significantly related. In comprising the lacrimal sac fossa, the maxillary bone accounted for a bigger proportion than the lacrimal bone. Male maxillary bone thickness was greater than female thickness. The authors also observed that maxillary bone thickness increased toward the upper areas of the lacrimal sac fossa and with increasing subject age. Understanding the form and variation of a normal lacrimal sac fossa is helpful for preparing for a

  17. The Aging Lacrimal Gland: Changes in Structure and Function

    PubMed Central

    Rocha, Eduardo M.; Alves, Monica; Rios, J. David; Dartt, Darlene A.

    2014-01-01

    The afferent nerves of the cornea and conjunctiva, efferent nerves of the lacrimal gland, and the lacrimal gland are a functional unit that works cooperatively to produce the aqueous component of tears. A decrease in the lacrimal gland secretory function can lead to dry eye disease. Because aging is a risk factor for dry eye disease, study of the changes in the function of the lacrimal gland functional unit with age is important for developing treatments to prevent dry eye disease. No one mechanism is known to induce the changes that occur with aging, although multiple different mechanisms have been associated with aging. These fall into two theoretical categories: programmed theories of aging (immunological, genetic, apoptotic, and neuroendocrine) and error theories of aging (protein alteration, somatic mutation, etc). Lacrimal glands undergo structural and functional alteration with increasing age. In mouse models of aging, it has been shown that neural stimulation of protein secretion is an early target of aging, accompanied by an increase in mast cells and lipofuscin accumulation. Hyperglycemia and increased lymphocytic infiltration can contribute to this loss of function at older ages. These findings suggest that an increase in oxidative stress may play a role in the loss of lacrimal gland function with age. For the afferent and efferent neural components of the lacrimal gland functional unit, immune or inflammatory mediated decrease in nerve function could contribute to loss of lacrimal gland secretion with age. More research in this area is critically needed. PMID:18827949

  18. The aging lacrimal gland: changes in structure and function.

    PubMed

    Rocha, Eduardo M; Alves, Monica; Rios, J David; Dartt, Darlene A

    2008-10-01

    The afferent nerves of the cornea and conjunctiva, efferent nerves of the lacrimal gland, and the lacrimal gland are a functional unit that works cooperatively to produce the aqueous component of tears. A decrease in the lacrimal gland secretory function can lead to dry eye disease. Because aging is a risk factor for dry eye disease, study of the changes in the function of the lacrimal gland functional unit with age is important for developing treatments to prevent dry eye disease. No one mechanism is known to induce the changes that occur with aging, although multiple different mechanisms have been associated with aging. These fall into two theoretical categories: programmed theories of aging (immunological, genetic, apoptotic, and neuroendocrine) and error theories of aging (protein alteration, somatic mutation, etc). Lacrimal glands undergo structural and functional alteration with increasing age. In mouse models of aging, it has been shown that neural stimulation of protein secretion is an early target of aging, accompanied by an increase in mast cells and lipofuscin accumulation. Hyperglycemia and increased lymphocytic infiltration can contribute to this loss of function at older ages. These findings suggest that an increase in oxidative stress may play a role in the loss of lacrimal gland function with age. For the afferent and efferent neural components of the lacrimal gland functional unit, immune or inflammatory mediated decrease in nerve function could contribute to loss of lacrimal gland secretion with age. More research in this area is critically needed.

  19. Lacrimal neuralgia: so far, a missing cranial neuralgia.

    PubMed

    Pareja, Juan A; Cuadrado, María-Luz

    2013-10-01

    The lacrimal nerve supplies the lacrimal gland, the lateral upper eyelid, and a small cutaneous area adjacent to the external CANTHUS . First division trigeminal neuralgia, supraorbital/supratrochlear neuralgia, and infraorbital neuralgia have been acknowledged as neuralgic causes of pain in the forehead and periorbit. However, the lacrimal nerve has never been identified as a source of facial pain. Here we report two cases of lacrimal neuralgia. A 66-year-old woman had continuous pain in the lateral aspect of her left superior eyelid and an adjacent area of the temple since age 64. A 33-year-old woman suffered from continuous pain in a small area next to the lateral CANTHUS of her left eye since age 25. In both patients the superoexternal edge of the orbit was tender. In addition, sensory dysfunction could be demonstrated within the painful area. Anaesthetic blockades of the lacrimal nerve with lidocaine 2% resulted in complete but short-lasting relief. Pregabalin provided a complete response in the first patient. The second patient was refractory to various oral and topical drugs and different radiofrequency procedures, but she eventually obtained partial relief with pregabalin. Lacrimal neuralgia should be considered among the neuralgic causes of orbital and periorbital pain.

  20. Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis.

    PubMed

    Machado, Marco Antonio de Campos; Silva, João Amaro Ferrari; Garcia, Eduardo Alonso; Allemann, Norma

    2017-06-01

    To compared the ultrasound findings of the lacrimal sac between subjects with normal lacrimal systems those with chronic dacryocystitis. A retrospective study of 10 subjects with a normal lacrimal system (Group 1) and 10 with chronic dacryocystitis (Group 2) diagnosed according to B-mode ultrasound with a 10-MHz transducer and the direct-contact technique (AVISO, Quantel Medical) for lacrimal sac assessment. We analyzed the dimensions, features, and content of the sacs. Characteristics of the population: female: 6, Group 1; 8, Group 2; mean age 48.4 years (SD=19.9; range, 22-80 years), Group 1; 50.5 years (SD=15.5; range, 25-75 years), Group 2. The dimensions of the lacrimal sac were as follows: anteroposterior 1.86 and 10.99 mm in Groups 1 and 2, respectively, p<0.0001; vertical 9.79 and 14.13 mm in Groups 1 and 2, respectively, p=0.049. Qualitative evaluation of the lacrimal sac contents showed hypoechogenic content in Group 1 (10, 100%) and hyperechogenic punctiform content in Group 2 (10, 100%) with partial filling in seven cases (70%). Ultrasonography can differentiate normal lacrimal sacs from sacs compromised by chronic dacryocystitis, thus being useful as an adjunct to clinical examination and surgical planning.

  1. Human lacrimal gland regeneration: Perspectives and review of literature

    PubMed Central

    Tiwari, Shubha; Ali, Mohammad Javed; Vemuganti, Geeta K.

    2013-01-01

    The human lacrimal gland is an essential component of the lacrimal functional unit (LFU). Any perturbation of this unit can lead to the debilitating morbid condition called the dry eye syndrome (DES). The current line of therapy available for dry eye remains supportive and palliative with the patient being dependent on life long and frequent administration of lubricating eye drops. Even advanced therapies like punctual plugs, cyclosporine B administration, and salivary gland auto-transplantation have led to a limited success. Under these scenarios, the option of cell based therapy needs to be explored to provide better and long term relief to these patients. This review gives an overview of the efforts in lacrimal gland regeneration and examines the past and ongoing research in cell based therapies in animals as well as human lacrimal gland cultures. The authors discuss their first of its kind functionally viable human lacrimal gland in vitro culture system from fresh exenteration specimens. A brief overview of research in near future and the potential implications of lacrimal gland regenerative therapies have been discussed. PMID:24526853

  2. Human lacrimal gland regeneration: Perspectives and review of literature.

    PubMed

    Tiwari, Shubha; Ali, Mohammad Javed; Vemuganti, Geeta K

    2014-01-01

    The human lacrimal gland is an essential component of the lacrimal functional unit (LFU). Any perturbation of this unit can lead to the debilitating morbid condition called the dry eye syndrome (DES). The current line of therapy available for dry eye remains supportive and palliative with the patient being dependent on life long and frequent administration of lubricating eye drops. Even advanced therapies like punctual plugs, cyclosporine B administration, and salivary gland auto-transplantation have led to a limited success. Under these scenarios, the option of cell based therapy needs to be explored to provide better and long term relief to these patients. This review gives an overview of the efforts in lacrimal gland regeneration and examines the past and ongoing research in cell based therapies in animals as well as human lacrimal gland cultures. The authors discuss their first of its kind functionally viable human lacrimal gland in vitro culture system from fresh exenteration specimens. A brief overview of research in near future and the potential implications of lacrimal gland regenerative therapies have been discussed.

  3. Functional lacrimal gland regeneration by transplantation of a bioengineered organ germ

    PubMed Central

    Hirayama, Masatoshi; Ogawa, Miho; Oshima, Masamitsu; Sekine, Yurie; Ishida, Kentaro; Yamashita, Kentaro; Ikeda, Kazutaka; Shimmura, Shigeto; Kawakita, Tetsuya; Tsubota, Kazuo; Tsuji, Takashi

    2013-01-01

    The lacrimal gland has a multifaceted role in maintaining a homeostatic microenvironment for a healthy ocular surface via tear secretion. Dry-eye disease, which is caused by lacrimal gland dysfunction, is one of the most prevalent eye diseases that cause corneal epithelial damage and results in significant loss of vision and a reduction in the quality of life. Here we demonstrate orthotopic transplantation of bioengineered lacrimal gland germs into adult mice with an extra-orbital lacrimal gland defect, a mouse model that mimics the corneal epithelial damage caused by lacrimal gland dysfunction. The bioengineered lacrimal gland germs and harderian gland germs both develop in vivo and achieve sufficient physiological functionality, including tear production in response to nervous stimulation and ocular surface protection. This study demonstrates the potential for bioengineered organ replacement to functionally restore the lacrimal gland. PMID:24084941

  4. Comparison of botulinum toxin-A injection in lacrimal gland and conjunctivodacryocystorhinostomy for treatment of epiphora due to proximal lacrimal system obstruction

    PubMed Central

    Kaynak, P; Karabulut, G O; Ozturker, C; Fazil, K; Arat, Y O; Perente, I; Akar, S; Yilmaz, O F; Demirok, A

    2016-01-01

    Purpose To investigate and compare the efficacy of botulinum toxin-A injection in the lacrimal gland and conjunctivodacryocystorhinostomy surgery for the treatment of epiphora caused by proximal lacrimal system obstruction. Methods Charts of the patients with proximal canalicular obstruction who had undergone conjunctivodacryocystorhinostomy with permanent tube insertion (18 patients, group 1) or 4 units of botulinum toxin-A injection in the palpebral lobe of the lacrimal gland (20 patients, group 2) were reviewed retrospectively. The upper lacrimal system obstruction was diagnosed by lacrimal system irrigation. Schirmer-1 test and Munk epiphora grading for evaluation of epiphora were performed before the interventions and on tenth day, first, third, and sixth months after the interventions. Results Improvement of epiphora was statistically significant at all visits when compared with values before injection (P<0.001) in both of groups. When two techniques were compared, difference in degree of epiphora before and after intervention was not statistically significant (P<0.05). In group 2, none of the patients had punctate epitheliopathy, although there was a significant decrease in Schirmer test results (P<0.001, paired t-test). In group 1, 9 cases (50%) had tube dislocation, 4 cases (22.2%) had obstruction, and granuloma formation. Five cases (25%) had ptosis in group 2. Conclusion  Conjunctivodacryocystorhinostomy requires surgical experience, special postoperative care, and multiple revisions. As botulinum toxin-A injection in the lacrimal gland is technically easy, less-invasive, safe, with reversible effects, it can be considered as an alternative treatment in patients with proximal lacrimal system obstruction. PMID:27197871

  5. Human lacrimal gland mucins.

    PubMed

    Paulsen, Friedrich; Langer, Gesa; Hoffmann, Werner; Berry, Monica

    2004-05-01

    The objective of this study was to determine whether the lacrimal gland synthesizes mucins and whether they are changed with age or in cases of dry eye. Expression of mucins in human lacrimal glands was monitored by reverse transcription-polymerase chain reaction analysis. Furthermore, the presence and distribution of MUC1, -2, -4, -5AC, -5B, -6 and -7 in epithelia of the human lacrimal gland and its excretory duct system were assessed with antisera to mucin peptide cores. Thirty normal tissues from cadavers of different ages were tested, plus four with dry eye treated with artificial tears. Expression studies detected mRNAs for mucins MUC1, -4, -5AC, -5B, -6 and -7; whereas the MUC2 message was absent. The message for MUC4 was present in all four cases of dry eye, but only in six out of the 30 normal glands from individuals who did not receive artificial tears. MUC6 mRNA was detected only in about half of the investigated samples. Immunohistochemistry revealed membrane-bound MUC1 at the apical surface of acinar cells, absence of MUC2, MUC5AC associated with goblet cells of excretory ducts, MUC5B and -7 in the cytoplasm of acinar cells, and MUC7 also in epithelial cells of excretory ducts. MUC4 mucin was detected only in those individuals in which message was identified. In dry eyes, MUC5AC and -5B were localized in the same acinar cells; whereas MUC2 and MUC6 were not detectable. Dot-blot analysis clearly revealed increased amounts of MUC4, -5AC, and -5B in the glands of elderly women who received treatment for dry eyes. These results confirm that the human lacrimal gland synthesizes a spectrum of mucins; part of them might be correlated with age. Copyright 2004 Springer-Verlag

  6. Breast carcinoma metastasis to the lacrimal gland: Two case reports

    PubMed Central

    NICKELSEN, MARIE N.; VON HOLSTEIN, SARAH; HANSEN, ALASTAIR B.; PRAUSE, JAN U.; HEEGAARD, STEFFEN

    2015-01-01

    A 77-year-old female, with proptosis, reduced eye motility and diplopia which had developed over two to three months and a 69-year-old female with proptosis, oedema of the eyelid, reduced motility and ptosis, which had developed over three weeks, are presented in the present study. Computed tomography scans revealed irregular lacrimal gland tumours in the two patients. The two patients had history of breast cancer. The first breast cancer metastasis in the lacrimal gland demonstrated a cribriform growth pattern containing ductal elements. The epithelial tumour cells stained positive for cytokeratin (1–8, 10, 14–16, 18 and 19), oestrogen receptor, epithelial membrane antigen (EMA), carcinoembryonic antigen (CEA) and gross cystic disease fluid protein 15 (GCDFP-15). The second metastatic tumour was positive for EMA and estrogen receptor, but variably positive for CEA and GCDFP-15. The metastasis in the lacrimal gland was a pleomorphic tumour. The tumour cells were positive for EMA and variably positive for oestrogen and CEA. Metastases to the lacrimal gland are extremely rare, and metastases to the lacrimal gland should be considered in the diagnoses of lacrimal gland tumours. The present study aimed to describe two such cases and draw attention to breast carcinomas as a differential diagnosis and the most frequent cause of lacrimal gland metastasis. PMID:26622620

  7. Polycystin-2 Expression and Function in Adult Mouse Lacrimal Acinar Cells

    PubMed Central

    Hilgenberg, Jill D.; Rybalchenko, Volodymyr; Medina-Ortiz, Wanda E.; Gregg, Elaine V.; Koulen, Peter

    2011-01-01

    Purpose. Lacrimal glands regulate the production and secretion of tear fluid. Dysfunction of lacrimal gland acinar cells can ultimately result in ocular surface disorders, such as dry eye disease. Ca2+ homeostasis is tightly regulated in the cellular environment, and secretion from the acinar cells of the lacrimal gland is regulated by both cholinergic and adrenergic stimuli, which both result in changes in the cytosolic Ca2+ concentration. We have previously described the detailed intracellular distribution of inositol-1,4,5-trisphosphate receptors (IP3Rs), and ryanodine receptors (RyRs) in lacrimal acinar cells, however, little is known regarding the expression and distribution of the third major class of intracellular Ca2+ release channels, transient receptor potential polycystin family (TRPP) channels. Methods. Studies were performed in adult lacrimal gland tissue of Swiss-Webster mice. Expression, localization, and intracellular distribution of TRPP Ca2+ channels were investigated using immunocytochemistry, immunohistochemistry, and electron microscopy. The biophysical properties of single polycystin-2 channels were investigated using a planar lipid bilayer electrophysiology system. Results. All channel-forming isoforms of TRPP channels (polycystin-2, polycystin-L, and polycystin-2L2) were expressed in adult mouse lacrimal gland. Subcellular analysis of immunogold labeling revealed strongest polycystin-2 expression on the membranes of the endoplasmic reticulum, Golgi, and nucleus. Biophysical properties of lacrimal gland polycystin-2 channels were similar to those described for other tissues. Conclusions. The expression of TRPP channels in lacrimal acinar cells suggests a functional role of the proteins in the regulation of lacrimal fluid secretion under physiological and disease conditions, and provides the basis for future studies focusing on physiology and pharmacology. PMID:21508103

  8. Movement of the lacrimal canalicular wall under intracanalicular pressure changes observed with dacryoendoscopy.

    PubMed

    Kakizaki, Hirohiko; Takahashi, Yasuhiro; Mito, Hidenori; Nakamura, Yasuhisa

    2015-01-01

    Movement of the lacrimal canalicular wall has been speculated to occur during blinking. Movement of the common internal ostium has been observed under nasal endoscopy, and pressure changes in the lacrimal canalicular cavity have been observed with a pressure sensor; however, lacrimal canalicular wall movement under pressure changes has not been observed. To examine movement of the lacrimal canalicular wall under intracanalicular pressure changes using dacryoendoscopy. The authors examined 20 obstruction-free lacrimal canaliculi in 10 patients. A dacryoendoscope was inserted, and water was poured into the intracanalicular cavity via the dacryoendoscope's water channel. The water was then poured or suctioned to cause positive or negative pressure changes in the intracanalicular cavity, and movement of the lacrimal canalicular wall was examined. The lacrimal canalicular wall moved flexibly with pressure changes. Under positive pressure, the intracanalicular cavity was dilated; however, it narrowed under negative pressure. The extent of movement was more dramatic in the common canalicular portion than the proximal canalicular portion. Intracanalicular pressure changes cause movement of the lacrimal canalicular wall. There was a consistent relationship between intracanalicular cavity changes and pressure changes, possibly contributing to lacrimal drainage of the canaliculus.

  9. [Evidence of lacrimal plugs via high resolution ultrasound].

    PubMed

    Tost, Frank H W; Darman, Jacques

    2003-07-01

    The practical value of high-frequency ultrasound (transducer frequency of 20 MHz) for studying lacrimal plugs positioned into canaliculi was proved. Twelve patients with twenty intracanalicular plugs and two punctum plugs were examined via high-frequency B-scan ultrasonography using 20 MHz transducer (model I3 Sacramento, USA). Detection and localisation of the intracanalicular plugs was made by a 20 MHz sector scanner. The ultrasound examinations were performed 1 - 24 month after the placement of lacrimal plugs. After patient's head positioning, the high-frequency ultrasound investigation was done via immersion fluid (2 % methylcellulose). All patients with dry eye treated by lacrimal plug implant showed echographic structure in the lacrimal canaliculus. In transversal echograms it was possible to image both canaliculi together when the lids were half-closed. Contrary to the normal state, it was not necessary to inject viscous fluid into the canaliculus. High-resolution ultrasound was able to differentiate the normal canaliculus from the findings after plug placement. The echograms can vary from one plug type to another. Highly reflective structures were found after the placement of silicone intracanalicular plugs, e. g. HERRICK-Plug. In contrast, the ultrasonic image taken through acrylic polymer intracanalicular plugs showed homogeneous small reflective inner structure, e. g. SMART-Plug. However, smooth and flat acoustic interface between acrylic polymer plug and the lacrimal canaliculus produced strong echoes. 20 MHz ultrasound seems to be well suited for the detection and localisation of intracanalicular plugs. By use of 20 MHz ultrasound scans it is possible to get high-quality images of the intracanalicular plug and around lacrimal canaliculus. Compared with UBM, the depth of penetration is much higher with negligible resolution. On the whole, we believe that 20 MHz ultrasound can become a useful tool for evaluating the placement of intracanalicular plugs

  10. Inaccuracy of diagnosis in a cohort of patients on the waiting list for dacryocystorhinostomy when the diagnosis was made by only syringing the lacrimal system.

    PubMed

    Beigi, B; Uddin, J M; McMullan, T F W; Linardos, E

    2007-01-01

    Accurate identification of the factors contributing to epiphora is essential in directing appropriate management and treatment strategies. The authors applied a methodical strategy of assessment for epiphora to patients who were already on the waiting list for dacryocystorhinostomy (DCR). The findings were compared to the original findings. Forty-four eyes of 35 patients listed for DCR were re-examined. All canaliculi were examined using four tests: dye disappearance, Jones 1 (dye retrieval), probing using Bowman probes, and syringing of the nasolacrimal duct (NLD) under local anesthesia. Some patients were examined using an endocanalicular mini-endoscope. Patients with NLD obstruction underwent DCR and those with canalicular and NLD stenosis underwent intubation of the lacrimal system-canaliculus, lacrimal sac, and nasolacrimal duct-using silicone stents. The authors refer to this as canaliculodacryocystoplasty (CDCP). The patients were assessed for symptoms of epiphora at 12 months. Forty-four eyes had been listed for DCR. They had been originally diagnosed, by means of lacrimal syringing, as NLD obstruction (24 eyes) or stenosis (12 eyes), and functional blocks (8 eyes). Four out of the original 44 planned DCR surgeries were performed after re-evaluation. After re-examination, 28 lacrimal systems were found to have canalicular stenosis, 4 NLD stenosis, 4 NLD obstruction, 4 punctal phimosis, 3 ocular surface disease, and 1 patient was asymptomatic. Twenty-eight lacrimal systems underwent CDCP, 4 underwent DCR, 4 had punctoplasty, and 4 had probing alone. Three had treatment for ocular surface disease and one patient required no treatment. After a follow-up of 12 months, 41 (93%) systems had improvement or were free of their Syringing of the lacrimal apparatus may result in a high false positive diagnosis of NLD obstruction. Canalicular pathology is not uncommon in this cohort of patients and may be underdiagnosed.

  11. A review on use of botulinum toxin for intractable lacrimal drainage disorders.

    PubMed

    Singh, Swati; Ali, Mohammad Javed; Paulsen, Friedrich

    2017-08-01

    To review the published literature on botulinum toxin (BTX) for epiphora secondary to refractory lacrimal drainage disorders. The authors performed a Pub Med search of all articles published in English on BTX injection into lacrimal gland for epiphora secondary to lacrimal drainage disorders. Relevant cross-references were obtained from the resultant studies. Data reviewed included demographics, indications, dose of BTX, number of injections, transconjunctival or transcutaneous route, outcomes and complications. Animal experiments of BTX into lacrimal gland were included and analyzed separately. Botulinum toxin injection into lacrimal gland, in animal studies, has shown to reduce the tear volume significantly lasting for approximately a month without any histological changes. The major indications have been refractory canalicular obstructions and functional epiphora. The commonly used dose was 2.5 U. Outcomes in the few studies published are encouraging with transient ptosis being the most common complication. Botulinum toxin into the lacrimal gland is a minimally invasive alternative in cases of refractory epiphora secondary to lacrimal drainage disorders. In these subsets of patients, the reported concentrations, dosage and outcome measures are variable and need larger studies for standardization.

  12. Sjögren-Like Lacrimal Keratoconjunctivitis in Germ-Free Mice

    PubMed Central

    Wang, Changjun; Zaheer, Mahira; Bian, Fang; Quach, Darin; Swennes, Alton G.; Britton, Robert A.; Pflugfelder, Stephen C.

    2018-01-01

    Commensal bacteria play an important role in the formation of the immune system but their role in the maintenance of immune homeostasis at the ocular surface and lacrimal gland remains poorly understood. This study investigated the eye and lacrimal gland phenotype in germ-free and conventional C57BL/6J mice. Our results showed that germ-free mice had significantly greater corneal barrier disruption, greater goblet cell loss, and greater total inflammatory cell and CD4+ T cell infiltration within the lacrimal gland compared to the conventionally housed group. A greater frequency of CD4+IFN-γ+ cells was observed in germ-free lacrimal glands. Females exhibited a more severe phenotype compared to males. Adoptive transfer of CD4+ T cells isolated from female germ-free mice into RAG1KO mice transferred Sjögren-like lacrimal keratoconjunctivitis. Fecal microbiota transplant from conventional mice reverted dry eye phenotype in germ-free mice and decreased CD4+IFN-γ+ cells to levels similar to conventional C57BL/6J mice. These findings indicate that germ-free mice have a spontaneous lacrimal keratoconjunctivitis similar to that observed in Sjögren syndrome patients and demonstrate that commensal bacteria function in maintaining immune homeostasis on the ocular surface. Thus, manipulation of intestinal commensal bacteria has the potential to become a novel therapeutic approach to treat Sjögren Syndrome. PMID:29438346

  13. Neurostimulation of the Lacrimal Nerve for Enhanced Tear Production

    PubMed Central

    Kossler, Andrea L.; Wang, Jianhua; Feuer, William; Tse, David T.

    2014-01-01

    Purpose To design a proof-of-concept study to assess the effect of lacrimal nerve stimulation (LNS) with an implantable pulse generator (IPG) to increase aqueous tear production. Methods Experimental animal study design of six Dutch Belted rabbits. Ultra high-resolution optical coherence tomography (UHR-OCT) quantified tear production by measuring the baseline tear volume of each rabbit’s right and left eye. A neurostimulator was implanted adjacent to the right lacrimal nerve. After two minutes of LNS (100 μs, 1.6 mAmp, 20 Hz, 5–8 volts), the tear volumes were measured with UHR-OCT. The change in tear volume was quantified and compared to the non-stimulated left eye. Three rabbits underwent chronic LNS (100 μS, 1.6 mAmp, 10 Hz, 2 volts) and their lacrimal glands were harvested for histopathologic analysis. Results UHR-OCT imaging of the right eyes tear volume showed a 441% average increase in tear production after LNS as a percent of baseline. After stimulation, right eyes had statistically significant greater increase in tear volumes than left eyes (p=0.028, Wilcoxon test). Post-stimulation right eye tear volumes were significantly greater compared to baseline (p=0.028, Wilcoxon test). Histopathologic examination of the lacrimal glands showed no discernible tissue damage from chronic neurostimulation. Additionally, there were no gross adverse effects on the general well-beings of the animals due to chronic stimulation. Conclusions Lacrimal nerve stimulation with an implantable pulse generator appears to increase aqueous tear production. Chronic LNS showed no histopathologic lacrimal gland damage. This study suggests LNS is a promising new treatment strategy to increase aqueous tear production. PMID:25126767

  14. Alx4 relays sequential FGF signaling to induce lacrimal gland morphogenesis

    PubMed Central

    Garg, Ankur; Gotoh, Noriko; Feng, Gen-Sheng; Zhong, Jian; Wang, Fen; Kariminejad, Ariana; Brooks, Steven

    2017-01-01

    The sequential use of signaling pathways is essential for the guidance of pluripotent progenitors into diverse cell fates. Here, we show that Shp2 exclusively mediates FGF but not PDGF signaling in the neural crest to control lacrimal gland development. In addition to preventing p53-independent apoptosis and promoting the migration of Sox10-expressing neural crests, Shp2 is also required for expression of the homeodomain transcription factor Alx4, which directly controls Fgf10 expression in the periocular mesenchyme that is necessary for lacrimal gland induction. We show that Alx4 binds an Fgf10 intronic element conserved in terrestrial but not aquatic animals, underlying the evolutionary emergence of the lacrimal gland system in response to an airy environment. Inactivation of ALX4/Alx4 causes lacrimal gland aplasia in both human and mouse. These results reveal a key role of Alx4 in mediating FGF-Shp2-FGF signaling in the neural crest for lacrimal gland development. PMID:29028795

  15. Alx4 relays sequential FGF signaling to induce lacrimal gland morphogenesis.

    PubMed

    Garg, Ankur; Bansal, Mukesh; Gotoh, Noriko; Feng, Gen-Sheng; Zhong, Jian; Wang, Fen; Kariminejad, Ariana; Brooks, Steven; Zhang, Xin

    2017-10-01

    The sequential use of signaling pathways is essential for the guidance of pluripotent progenitors into diverse cell fates. Here, we show that Shp2 exclusively mediates FGF but not PDGF signaling in the neural crest to control lacrimal gland development. In addition to preventing p53-independent apoptosis and promoting the migration of Sox10-expressing neural crests, Shp2 is also required for expression of the homeodomain transcription factor Alx4, which directly controls Fgf10 expression in the periocular mesenchyme that is necessary for lacrimal gland induction. We show that Alx4 binds an Fgf10 intronic element conserved in terrestrial but not aquatic animals, underlying the evolutionary emergence of the lacrimal gland system in response to an airy environment. Inactivation of ALX4/Alx4 causes lacrimal gland aplasia in both human and mouse. These results reveal a key role of Alx4 in mediating FGF-Shp2-FGF signaling in the neural crest for lacrimal gland development.

  16. Lacrimal fossa lesions: a review of 146 cases in Egypt

    PubMed Central

    Eldesouky, Mohammed A; Elbakary, Molham A; Sabik, Saly; Shareef, Mohamed M

    2014-01-01

    Purpose The incidence and clinical and imaging criteria of different pathological forms of lacrimal fossa lesions in the Delta region of Egypt were studied. Methods A retrospective study of patients with lacrimal fossa lesions for the past 10 years was conducted. A total of 146 cases were identified. Their medical records were reviewed for clinical and imaging data (computed tomography scan, magnetic resonance imaging scan, or both). A definitive diagnosis based on pathological examination of biopsies was also reviewed. Results Among the patients reviewed, 43.15% had inflammatory lacrimal gland lesions, 26.71% had lymphoproliferative lesions, and 21.92% had epithelial lesions; 8.22% had rare lesions (5.48% were dacryops and 2.74% had hemangioma). The study included 71.92% benign lesions and 28.08% malignant lesions, which were distributed between 19.18% malignant lymphoma and 8.9% malignant epithelial tumors. According to the pathological origin of the lesions, they may be classified into 78.08% nonepithelial lesions and 21.92% epithelial lesions (16.44% epithelial tumors, and 5.48% dermoid cysts). Conclusion Lacrimal fossa lesions show a wide pathological range. Inflammatory lesions are most frequent, followed by lymphoproliferative and epithelial lesions. Analysis of clinical and radiological criteria is helpful in the differential diagnosis of lacrimal gland lesions. PMID:25210428

  17. Isolated lacrimal gland involvement in Rosai-Dorfman-Destombes disease

    PubMed Central

    Bhalla, Sunita; Srivastava, Amit

    2008-01-01

    Rosai-Dorfman-Destombes (sinus histiocytosis with massive lymphadenopathy) disease is an uncommon disease characterized by benign proliferation of histiocytes, with painless lymph node enlargement and frequent extranodal disease. Orbital involvement occurs in 9-11% of cases. However, isolated Rosai- Dorfman-Destombes disease of the lacrimal gland without any systemic involvement is very rare with only three case reports. We describe here one such young male patient with unilateral lacrimal gland swelling. Excision biopsy revealed almost complete replacement of the lacrimal gland by lymphocytes, plasma cells and large pale histiocytes. The latter exhibited emperipolesis and stained positive for S-100 and CD68 on immunohistochemistry. Patient is well and has no other manifestation or recurrence of the disease during a follow-up of 24 months. PMID:18974525

  18. The role of the lacrimal functional unit in the pathophysiology of dry eye.

    PubMed

    Stern, Michael E; Gao, Jianping; Siemasko, Karyn F; Beuerman, Roger W; Pflugfelder, Stephen C

    2004-03-01

    The majority of dry eye symptoms are due to a chronic inflammation of the lacrimal functional unit resulting in a loss of tear film integrity and normal function. This leads to a reduction in the ability of the ocular surface to respond to environmental challenges. The underlying cause of tear film dysfunction is the alteration of tear aqueous, mucin, and lipid components. This may result from a systemic autoimmune disease or a local autoimmune event. A lack of systemic androgen support to the lacrimal gland has been shown to be a facilitative factor in the initiation of this type of pathophysiology. Tear secretion is controlled by the lacrimal functional unit consisting of the ocular surface (cornea, conjunctiva, accessory lacrimal glands, and meibomian glands), the main lacrimal gland and the interconnecting innervation. If any portion of this functional unit is compromised, lacrimal gland support to the ocular surface is impeded. Factors such as neurogenic inflammation and T cell involvement in the disease pathogenesis as well as newly developed animal models of ocular surface inflammation are discussed.

  19. Quality of Vision in Eyes With Epiphora Undergoing Lacrimal Passage Intubation.

    PubMed

    Koh, Shizuka; Inoue, Yasushi; Ochi, Shintaro; Takai, Yoshihiro; Maeda, Naoyuki; Nishida, Kohji

    2017-09-01

    To investigate visual function and optical quality in eyes with epiphora undergoing lacrimal passage intubation. Prospective case series. Thirty-four eyes of 30 patients with lacrimal passage obstruction were enrolled. Before and 1 month after lacrimal passage intubation, functional visual acuity (FVA), higher-order aberrations (HOAs), lower tear meniscus, and tear clearance were assessed. An FVA measurement system was used to examine changes in continuous visual acuity (VA) over time, and visual function parameters such as FVA, visual maintenance ratio, and blink frequency were obtained. Sequential ocular HOAs were measured for 10 seconds after the blink using a wavefront sensor. Aberration data were analyzed in the central 4 mm for coma-like, spherical-like, and total HOAs. Fluctuation and stability indices of the total HOAs over time were calculated. Lower tear meniscus was assessed by anterior segment optical coherence tomography. After lacrimal passage intubation, visual function significantly improved, as indicated by improved FVA (P = .003) and visual maintenance ratio (P < .001). Blink frequency decreased significantly after treatment (P = .01). Optical quality significantly improved, as indicated by a decrease in coma-like aberrations (P = .003), spherical-like aberrations (P = .018), and total HOAs (P = .001). Stability index increased (P < .001) and fluctuation index decreased (P = .019), and tear meniscus dimension decreased (P < .001). Lacrimal passage intubation for eyes with epiphora significantly improved visual function and optical quality via patency of the lacrimal passage. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Computed tomography of the lacrimal drainage system: retrospective study of 107 cases of dacryostenosis.

    PubMed

    Francis, I C; Kappagoda, M B; Cole, I E; Bank, L; Dunn, G D

    1999-05-01

    To evaluate the role of computed tomography in patients with dacryostenosis. One hundred seven cases of dacryostenosis (94 patients) were assessed by thorough clinical and lacrimal history and examination, and lacrimal region computerized tomography (CT). The lacrimal drainage system examination included the state and position of the puncta; Jones testing; lacrimal syringing; and, in the latter half of the study, telescopic nasal endoscopy. The patients were drawn from the hospital outpatients and private office of the operating lacrimal surgeon in this series (I.C.F.). Of the 107 cases, 79 either underwent dacryocystorhinostomy surgery or had this planned. In 14 of the 107 cases (12 patients), preoperative CT led to an alteration of patient management, usually referral to an otolaryngologist for further evaluation or treatment. In addition to the detection of two tumors extrinsic to the sac, conditions such as ethmoiditis, lacrimal sac mucoceles, soft tissue opacity in the nasolacrimal duct, gross nasal polyposis, fungal sinusitis, and a dacryolith were observed by CT. Similar to the role of functional endoscopic sinus surgery in otolaryngology, CT imaging will become increasingly important in the assessment of many patients with symptoms of lacrimal drainage obstruction.

  1. Neural Regulation of Lacrimal Gland Secretory Processes: Relevance in Dry Eye Diseases

    PubMed Central

    Dartt, Darlene A.

    2013-01-01

    The lacrimal gland is the major contributor to the aqueous layer of the tear film which consists of water, electrolytes and proteins. The amount and composition of this layer is critical for the health, maintenance, and protection of the cells of the cornea and conjunctiva (the ocular surface). Small changes in the concentration of tear electrolytes have been correlated with dry eye syndrome. While the mechanisms of secretion of water, electrolytes and proteins from the lacrimal gland differ, all three are under tight neural control. This allows for a rapid response to meet the needs of the cells of the ocular surface in response to environmental conditions. The neural response consists of the activation of the afferent sensory nerves in the cornea and conjunctiva to stimulate efferent parasympathetic and sympathetic nerves that innervate the lacrimal gland. Neurotransmitters are released from the stimulated parasympathetic and sympathetic nerves that cause secretion of water, electrolytes, and proteins from the lacrimal gland and onto the ocular surface. This review focuses on the neural regulation of lacrimal gland secretion under normal and dry eye conditions. PMID:19376264

  2. Isolation and Propagation of Mesenchymal Stem Cells from the Lacrimal Gland

    PubMed Central

    You, Samantha; Kublin, Claire L.; Avidan, Orna; Miyasaki, David

    2011-01-01

    Purpose. Previously, it was reported that the murine lacrimal gland is capable of repair after experimentally induced injury and that the number of stem/progenitor cells was increased during the repair phase (2–3 days after injury). The aim of the present study was to determine whether these cells can be isolated from the lacrimal gland and propagated in vitro. Methods. Lacrimal gland injury was induced by injection of interleukin (IL)-1, and injection of saline vehicle served as control. Two and half days after injection, the lacrimal glands were removed and used to prepare explants or acinar cells for tissue culture. Cells derived from the explants and the acinar cells were grown in DMEM supplemented with 10% fetal bovine serum. Cells were stained for the stem cells markers, nestin, vimentin, ABCG2, and Sca-1. Cell proliferation was measured using an antibody against Ki67 or a cell-counting kit. The adipogenic capability of these cells was also tested in vitro. Results. Results show that nestin-positive cells can be isolated from IL-1–injected, but not saline-injected, lacrimal glands. A population of nestin-positive cells was also positive for vimentin, an intermediate filament protein expressed by mesenchymal cells. In addition, cultured cells expressed two other markers of stem cells, ABCG2 and Sca-1. These cells proliferated in vitro and can be induced to form adipocytes, attesting to their mesenchymal stem cell property. Conclusions. Murine lacrimal glands contain mesenchymal stem cells that seem to play a pivotal role in tissue repair. PMID:21178145

  3. Endoscopic Dacrocystorhinostomy in Lacrimal Canalicular Trauma

    PubMed Central

    Khan, Humayun A; Bayat, Aredeshir; De Carpentier, JP

    2007-01-01

    A case is presented where the common insertion of the upper and lower canaliculus of the lacrimal sac was repaired using endoscopic dacrocystorhinostomy (DCR) techniques, with silicone stenting and securing of stents intranasally. PMID:17316509

  4. The Relation Between Light-Induced Lacrimation and the Melanopsin-Driven Postillumination Pupil Response.

    PubMed

    Lei, Shaobo; Goltz, Herbert C; Chen, Xingqiao; Zivcevska, Marija; Wong, Agnes M F

    2017-03-01

    To investigate the chromatic characteristics and intensity-response function of light-induced reflex lacrimation and its correlation with the melanopsin-driven postillumination pupil response (PIPR). Eleven visually normal participants completed the experiment. Lacrimation was measured in one eye by placing a calibrated filter paper strip in the conjunctival sac over a 1 minute-interval (Schirmer's test) during which participants received either no light stimulation (baseline trial) or one flash of blue or red light stimuli presented binocularly with a Ganzfeld stimulator, while the pupil response was recorded simultaneously from the fellow eye by using an eye tracker. Light stimulation trials were presented in alternating fashion at seven incremental intensity steps (0.1, 1, 3.16, 10, 31.6, 100, and 400 cd/m2). Postillumination pupil response was defined as the mean pupil constriction from 10 to 30 seconds post illumination. The amount of lacrimation in response to 10 to 400 cd/m2 blue light was significantly greater than baseline and increased monotonically with increasing light intensity. Red light did not induce significant reflex lacrimation until the brightest stimulation at 400 cd/m2. There was a positive linear correlation between PIPR and lacrimation in response to blue light (r = 0.74, P < 0.001) but not to red light (r = 0.13, P = 0.25). The chromatic characteristics and intensity-response of light-induced lacrimation are highly consistent with the features of melanopsin phototransduction. This finding is the first in vivo evidence in humans, supporting the hypothesis that light-induced reflex lacrimation is mediated primarily by melanopsin photoactivity, and provides new insight into the putative mechanisms of photophobia.

  5. The pathology of dry eye: the interaction between the ocular surface and lacrimal glands.

    PubMed

    Stern, M E; Beuerman, R W; Fox, R I; Gao, J; Mircheff, A K; Pflugfelder, S C

    1998-11-01

    Most dry-eye symptoms result from an abnormal, nonlubricative ocular surface that increases shear forces under the eyelids and diminishes the ability of the ocular surface to respond to environmental challenges. This ocular-surface dysfunction may result from immunocompromise due to systemic autoimmune disease or may occur locally from a decrease in systemic androgen support to the lacrimal gland as seen in aging, most frequently in the menopausal female. Components of the ocular surface (cornea, conjunctiva, accessory lacrimal glands, and meibomian glands), the main lacrimal gland, and interconnecting innervation act as a functional unit. When one portion is compromised, normal lacrimal support of the ocular surface is impaired. Resulting immune-based inflammation can lead to lacrimal gland and neural dysfunction. This progression yields the OS symptoms associated with dry eye. Restoration of lacrimal function involves resolution of lymphocytic activation and inflammation. This has been demonstrated in the MRL/lpr mouse using systemic androgens or cyclosporine and in the dry-eye dog using topical cyclosporine. The efficacy of cyclosporine may be due to its immunomodulatory and antiinflammatory (phosphatase inhibitory capability) functions on the ocular surface, resulting in a normalization of nerve traffic. Although the etiologies of dry eye are varied, common to all ocular-surface disease is an underlying cytokine/receptor-mediated inflammatory process. By treating this process, it may be possible to normalize the ocular surface/lacrimal neural reflex and facilitate ocular surface healing.

  6. Lacrimal gland uptake of (67)Ga-gallium citrate correlates with biopsy results in patients with suspected sarcoidosis.

    PubMed

    Tannen, Bradford L; Kolomeyer, Anton M; Turbin, Roger E; Frohman, Larry; Langer, Paul D; Oh, Cheongeun; Ghesani, Nasrin V; Zuckier, Lionel S; Chu, David S

    2014-02-01

    To investigate whether lacrimal gland uptake on (67)Ga-gallium citrate scintigraphy correlates with histopathologic evidence of sarcoidosis. A retrospective, pilot study of 31 patients with suspected sarcoidosis who underwent gallium scintigraphy and lacrimal gland biopsy. Lacrimal gland gallium uptake was assessed by subjective visual scoring (SVS) and lacrimal uptake ratio (LUR). Eleven (36%) patients had lacrimal gland biopsies containing noncaseating granulomas. A statistically significant correlation was found between lacrimal gland gallium uptake and biopsy positivity using SVS (p = 0.03) or LUR (p = 0.01). Using SVS, biopsy positivity rate increased from 0 to 50% in patients with mild to intense uptake. Using LUR, biopsy positivity rate increased linearly as the ratio increased from 13% (LUR < 4) to 100% (LUR > 8). Lacrimal biopsy positivity rate significantly correlated with gallium uptake on scintigraphy. Both SVS and LUR methods appear to correlate with histologic results and may potentially aid in patient selection for biopsy.

  7. Glycosaminoglycan-dependent restriction of FGF diffusion is necessary for lacrimal gland development

    PubMed Central

    Qu, Xiuxia; Pan, Yi; Carbe, Christian; Powers, Andrea; Grobe, Kay; Zhang, Xin

    2012-01-01

    Glycosaminoglycans (GAGs) play a central role in embryonic development by regulating the movement and signaling of morphogens. We have previously demonstrated that GAGs are the co-receptors for Fgf10 signaling in the lacrimal gland epithelium, but their function in the Fgf10-producing periocular mesenchyme is still poorly understood. In this study, we have generated a mesenchymal ablation of UDP-glucose dehydrogenase (Ugdh), an essential biosynthetic enzyme for GAGs. Although Fgf10 RNA is expressed normally in the periocular mesenchyme, Ugdh mutation leads to excessive dispersion of Fgf10 protein, which fails to elicit an FGF signaling response or budding morphogenesis in the presumptive lacrimal gland epithelium. This is supported by genetic rescue experiments in which the Ugdh lacrimal gland defect is ameliorated by constitutive Ras activation in the epithelium but not in the mesenchyme. We further show that lacrimal gland development requires the mesenchymal expression of the heparan sulfate N-sulfation genes Ndst1 and Ndst2 but not the 6-O and 2-O-sulfation genes Hs6st1, Hs6st2 and Hs2st. Taken together, these results demonstrate that mesenchymal GAG controls lacrimal gland induction by restricting the diffusion of Fgf10. PMID:22745308

  8. [Traumatic Lacrimal Duct Stenosis: Demographics and Success Rate of Surgical Procedures for Secondary Treatment].

    PubMed

    Alnawaiseh, M; Böhm, M R R; Rosentreter, A; Wieneke, A C; Wirths, G; Merté, R L; Eter, N; Zumhagen, L

    2016-06-01

    Traumatic lacrimal duct stenosis can be the result of sharp trauma of the eyelid, indirect trauma or surgery in the nasoorbital region, as well as burns, chemotherapy and radiation of the facial region. The aim of the study is to present the demographics, patient satisfaction, and course of different surgical procedures for secondary treatment of traumatic lacrimal duct stenosis. We retrospectively reviewed the medical records of 50 patients who required surgery for traumatic lacrimal duct stenosis from 2009 to 2011 at the University Eye Hospital in Muenster. The evaluation included the following criteria: age, sex, duration of symptoms, complication rate and the rate of recurrence. We systematically evaluated the medical data and asked the patients about the recent symptoms via telephone questionnaire. 60 eyes of 50 patients were included (18 women; 32 men; age: 51.8 ± 17.1 years); 34 eyes (56.7 %) had already had operations of the lacrimal system. The success rate was 58.1 %. The mean postoperative follow-up was 52.3 ± 10.7 months. In 11 cases (18.3 %), a dakryocystorhinostomy (DCR) was necessary. Traumatic lacrimal stenosis is more common in men, and has a poorer prognosis than lacrimal duct stenosis from other causes. Georg Thieme Verlag KG Stuttgart · New York.

  9. Gene Expression in Human Accessory Lacrimal Glands of Wolfring

    PubMed Central

    Ubels, John L.; Gipson, Ilene K.; Spurr-Michaud, Sandra J.; Tisdale, Ann S.; Van Dyken, Rachel E.; Hatton, Mark P.

    2012-01-01

    Purpose. The accessory lacrimal glands are assumed to contribute to the production of tear fluid, but little is known about their function. The goal of this study was to conduct an analysis of gene expression by glands of Wolfring that would provide a more complete picture of the function of these glands. Methods. Glands of Wolfring were isolated from frozen sections of human eyelids by laser microdissection. RNA was extracted from the cells and hybridized to gene expression arrays. The expression of several of the major genes was confirmed by immunohistochemistry. Results. Of the 24 most highly expressed genes, 9 were of direct relevance to lacrimal function. These included lysozyme, lactoferrin, tear lipocalin, and lacritin. The glands of Wolfring are enriched in genes related to protein synthesis, targeting, and secretion, and a large number of genes for proteins with antimicrobial activity were detected. Ion channels and transporters, carbonic anhydrase, and aquaporins were abundantly expressed. Genes for control of lacrimal function, including cholinergic, adrenergic, vasoactive intestinal polypeptide, purinergic, androgen, and prolactin receptors were also expressed in gland of Wolfring. Conclusions. The data suggest that the function of glands of Wolfring is similar to that of main lacrimal glands and are consistent with secretion electrolytes, fluid, and protein under nervous and hormonal control. Since these glands secrete directly onto the ocular surface, their location may allow rapid response to exogenous stimuli and makes them readily accessible to topical drugs. PMID:22956620

  10. The Epidemiological, Clinical, and Histopathological Characteristics of Lacrimal Gland Biopsies in a Tertiary Care Center in Israel.

    PubMed

    Priel, Ayelet; Vishnevskia-Dai, Vicktoria; Hochma, Liran; Gildener-Leapman, Juliana; Ben Simon, Guy J; Rosner, Mordechai; Antman, Gal; Zloto, Ofira

    2018-02-01

    The distribution of pathology and clinical characteristics of lacrimal gland diseases are different in different areas of the world. To evaluate the incidence rate, patient characteristics, and indications for surgical intervention of lacrimal gland lesions in a tertiary care center in Israel. All biopsied or surgically removed lacrimal gland lesions at the Goldschleger Eye Institute from 2009 to 2015 were identified. The following data were collected: age, gender, indications for surgical intervention, diagnosis, treatment, and prognosis. We evaluated 28 lacrimal gland biopsies from 26 patients (11 men, 15 women). Mean age at biopsy was 47.5 years old. The most common presenting symptoms were: eyelid swollenness (57.14%), ptosis (32.14%), and proptosis (10.71%). All patients underwent computed tomography and magnetic resonance imaging. In 28 cases, infiltrations of the lacrimal gland were found. In nine cases infiltration of muscles or orbital extension were found. The most common pathologies were non-specified inflammation (44.82%), lymphoma (20.68%), and immunoglobulin G4-related disease (10.34%). The treatment was diverse according to the patient diagnosis. Prognosis of lacrimal gland disease was good; however, in five patients the systemic disease progressed. Lesions of the lacrimal gland comprise a wide variety of pathological findings that require different treatment strategies. Lacrimal gland biopsies enable physicians to precisely recognize the pathology; therefore, it is important to consider this surgical method in any patient with lesions in the lacrimal gland.

  11. Gross, Histologic, and Computed Tomographic Anatomy of the Lacrimal System of Snakes

    PubMed Central

    Souza, Nicole M.; Maggs, David J.; Park, Shin Ae; Puchalski, Sarah; Reilly, Christopher M.; Paul-Murphy, Joanne; Murphy, Christopher J.

    2014-01-01

    Objective To describe the lacrimal system of snakes using contrast micro-computed tomography (micro-CT) with 3-dimensional reconstruction, fluorescein passage (“Jones”) testing, histology, and gross dissection. Animals studied One Royal Python and 19 snake cadavers representing 10 species. Procedures Direct observation following injection of fluorescein into the subspectacular space, micro-CT following injection of 3 contrast agents into the subspectacular space, gross dissection following injection of latex into the subspectacular space, and histopathology. Results Injection of fluorescein confirmed patency but not course of the lacrimal duct. Barium enabled clear visualization of the lacrimal duct whereas two iodinated contrast agents proved inadequate. Collectively, micro-CT, anatomic dissections, and histology suggest tears are produced by a single, large, serous, retrobulbar gland, released into the subspectacular space via several ductules, and drained through a single punctum originating in the ventronasal subspectacular space and the lacrimal duct taking one of 3 routes of variable tortuosity before opening into the oral cavity in close association with the opening of the duct of the vomeronasal organ. Conclusions The ophidian lacrimal duct has a generally tortuous course and the details of its anatomy is species variable. The tortuous course of the duct likely predisposes snakes to duct occlusion and must be considered when planning medical and surgical interventions in snakes with pseudobuphthalmos and subspectacular abscessation. PMID:24862081

  12. Primary Mucoepidermoid Carcinoma of the Lacrimal Sac -  a Case Report and Literature Review.

    PubMed

    Janakiram, T N; Sagar, S; Sharma, S B; Subramaniam, V

    Lacrimal sac tumors are very rare and are often missed because patients present with features consistent with chronic dacryocystitis. Squamous cell carcinoma is the common-est lacrimal sac malignancy. Although primary mucoepidermoid carcinomas of the lacrimal sac are rare, they are locally aggressive. Furthermore, their proximity to vital structures and the skull base makes them potentially life-threatening. Multidisciplinary management is required, and wide excision followed by chemoradiation is the recommended treatment. Here, we report a 65-year-old male who presented with watering eyes and a mass in the region of the medial canthus. A dia-gnosis of primary mucoepidermoid carcinoma of the lacrimal sac was made, and the case was managed successfully with radical surgery and reconstruction. The tumor was resected using the extended Lynch-Howarth incision and the resulting defect was reconstructed using a forehead flap. Histopathological examination of the excised specimen revealed mucoepidermoid carcinoma. Immunohistochemical analysis revealed that the speci-men was positive for epithelial growth factor receptor and Ki-67 protein. The patient was referred for post-operative chemoradiation. The literature is reviewed and pathological features, including immunohistochemistry are discussed. Primary mucoepidermoid carcinoma of the lacrimal sac is a rare, locally aggressive tumor that is often mistaken for dacryocystitis. The treatment of choice is radical surgery followed by chemoradiation. lacrimal sac -  mucoepidermoid carcinoma -  epithelial growth factor receptor -  Ki-67 protein.

  13. Salivation induced better lacrimal gland function in dry eyes.

    PubMed

    Pramanik, T; Ghising, R

    2009-12-01

    The dry eye syndrome is a common eye symptom causing blurry vision. To meet the demand of the modem world students and professionals are compelled to expose themselves to the computer screen for long stretch of time, which is one of the causes of dry eye. It is not always feasible to instil eyes with artificial tears time to time to protect them from dryness. Rather to adopt any simple physiological process associated with optimum lacrimation is a better option to keep eyes moist during computer works. Volunteers (n = 22) having mild dry eyes participated in this study. Tear production was assessed by Schirmer test by keeping Schirmer strip on ocular surface for 5 minutes and recording the length of the moistened area. Then the subject was allowed to keep a piece of lopsy candy (a sour fruit pulp mixed with sugar that is sweet and sour in taste) in mouth for 5 minutes that caused salivation. During salivation, again tear production was assessed. [It was standardized in such a way that, the length of the moistened strip will be 25 - 30 mm for normal eyes, 15 - 10 mm for dry eye, 06 - 10 mm for mild dry eye, 02 - 05 mm for moderate dryness and 00 - 01 mm for severe dry eye.] Tear production was found to be increased significantly (supported by increased length of moistened area of Schirmer strip) during salivation especially in dry eye in all volunteers. The lacrimal gland is the major contributor to the aqueous layer of the tear film which consists of water, electrolytes and proteins; secretion of which are under tight neural control. Anticholinergic agents play an important role in ocular dryness because of hypo-secretion. The sensory root of facial nucleus contains efferent preganglionic parasympathetic fibers for submandibular and sublingual salivary gland and lacrimal gland. The sensory root conveys gustatory fibers from the presulcul area (anterior two-third) of the tongue via the chorda tympani and via the palatine and greater petrosal nerve, taste fibers from

  14. Adenoid cystic carcinoma of the lacrimal gland.

    PubMed

    Sanders, Jason C; Mendenhall, William M; Werning, John W

    2016-01-01

    This is a retrospective analysis of the 50-year University of Florida experience treating adenoid cystic carcinoma of the lacrimal gland with radiation therapy. Between 1965 and 2015, 8 patients with adenoid cystic carcinoma of the lacrimal gland received radiation therapy with curative intent. Four patients received postoperative radiation therapy and 4 received definitive radiation therapy alone. The median follow-up was 3.3 years (range, 0.3 to 11.2 years). All 4 patients who received postoperative radiation therapy received 74.4 Gy. The 4 patients who received radiation therapy alone received a median dose of 72.3 Gy (range, 70.0 to 74.4 Gy). The overall survival rates at 5 and 10 years were 25% and 13%, respectively. The cause-specific survival rates at 5 and 10 years were 29% and 14%, respectively. The local control and freedom from metastases rates at 5 and 10 years were both 43%. Local recurrences occurred in 50% of patients, and distant metastatic disease occurred in 38% of patients. No patients experienced acute complications of treatment that warranted a treatment break. Two patients experienced bone exposure as late complications of treatment. The results of this study illustrate the propensity for adenoid cystic carcinoma of the lacrimal gland to recur both locally and with distant metastases despite aggressive local treatment measures. This study also demonstrates the relatively poor outcomes for individuals with this type of tumor. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. A Single Injection of Interleukin-1 Induces Reversible Aqueous-tear Deficiency, Lacrimal Gland Inflammation, and Acinar and Ductal Cell Proliferation

    PubMed Central

    Zoukhri, Driss; Macari, Elizabeth; Kublin, Claire L.

    2011-01-01

    Emerging studies from our laboratory demonstrate that interleukin-1 (IL-1) family members play a major role in impairing lacrimal gland functions. Here we have extended our investigations to observe the effects of IL-1 on aqueous tear production, lacrimal gland secretion, lacrimal gland histology, and acinar and ductal cell proliferation. We demonstrate that a single injection of IL-1 into the lacrimal glands inhibited neurally- as well as agonist-induced protein secretion resulting in decreased tear output. Meanwhile, IL-1 injection induced a severe, but reversible (7–13 days), inflammatory response that led to destruction of lacrimal gland acinar epithelial cells. Finally, we demonstrate that as the inflammatory response subsided and lacrimal gland secretion and tear production returned to normal levels, there was increased proliferation of acinar and ductal epithelial cells. Our work uncovers novel effects of IL-1 on lacrimal gland functions and the potential regenerative capacity of the mouse lacrimal gland. PMID:17362931

  16. Epithelial Markers aSMA, Krt14, and Krt19 Unveil Elements of Murine Lacrimal Gland Morphogenesis and Maturation.

    PubMed

    Kuony, Alison; Michon, Frederic

    2017-01-01

    As an element of the lacrimal apparatus, the lacrimal gland (LG) produces the aqueous part of the tear film, which protects the eye surface. Therefore, a defective LG can lead to serious eyesight impairment. Up to now, little is known about LG morphogenesis and subsequent maturation. In this study, we delineated elements of the cellular and molecular events involved in LG formation by using three epithelial markers, namely aSMA, Krt14, and Krt19. While aSMA marked a restricted epithelial population of the terminal end buds (TEBs) in the forming LG, Krt14 was found in the whole embryonic LG epithelial basal cell layer. Interestingly, Krt19 specifically labeled the presumptive ductal domain and subsequently, the luminal cell layer. By combining these markers, the Fucci reporter mouse strain and genetic fate mapping of the Krt14 + population, we demonstrated that LG epithelium expansion is fuelled by a patterned cell proliferation, and to a lesser extent by epithelial reorganization and possible mesenchymal-to-epithelial transition. We pointed out that this epithelial reorganization, which is associated with apoptosis, regulated the lumen formation. Finally, we showed that the inhibition of Notch signaling prevented the ductal identity from setting, and led to a LG covered by ectopic TEBs. Taken together our results bring a deeper understanding on LG morphogenesis, epithelial domain identity, and organ expansion.

  17. Epithelial Markers aSMA, Krt14, and Krt19 Unveil Elements of Murine Lacrimal Gland Morphogenesis and Maturation

    PubMed Central

    Kuony, Alison; Michon, Frederic

    2017-01-01

    As an element of the lacrimal apparatus, the lacrimal gland (LG) produces the aqueous part of the tear film, which protects the eye surface. Therefore, a defective LG can lead to serious eyesight impairment. Up to now, little is known about LG morphogenesis and subsequent maturation. In this study, we delineated elements of the cellular and molecular events involved in LG formation by using three epithelial markers, namely aSMA, Krt14, and Krt19. While aSMA marked a restricted epithelial population of the terminal end buds (TEBs) in the forming LG, Krt14 was found in the whole embryonic LG epithelial basal cell layer. Interestingly, Krt19 specifically labeled the presumptive ductal domain and subsequently, the luminal cell layer. By combining these markers, the Fucci reporter mouse strain and genetic fate mapping of the Krt14+ population, we demonstrated that LG epithelium expansion is fuelled by a patterned cell proliferation, and to a lesser extent by epithelial reorganization and possible mesenchymal-to-epithelial transition. We pointed out that this epithelial reorganization, which is associated with apoptosis, regulated the lumen formation. Finally, we showed that the inhibition of Notch signaling prevented the ductal identity from setting, and led to a LG covered by ectopic TEBs. Taken together our results bring a deeper understanding on LG morphogenesis, epithelial domain identity, and organ expansion. PMID:29033846

  18. Patterns of innervation of the lacrimal gland with clinical application.

    PubMed

    Scott, Gabriel; Balsiger, Heather; Kluckman, Matthew; Fan, Jerry; Gest, Thomas

    2014-11-01

    Parasympathetic stimulation of the lacrimal gland is responsible for tear production, and this innervation originates from fibers conveyed in the facial nerve. After synapse in the pterygopalatine ganglion, postsynaptic parasympathetic fibers travel within the zygomatic and zygomaticotemporal nerves (ZTN) into the orbit. As described in most anatomy texts, ZTN communicates with the lacrimal nerve (LN) posterior to the gland and then secretomotor fibers enter the gland. This study was performed to gain a better understanding of the innervation of the lacrimal gland. Seventeen cadaver heads were bisected for a total of 34 sides, which then underwent dissection of the superolateral orbital region to observe the course for the LN and ZTN. Three variations of the course of the LN and ZTN were found. In 20 (60.6%) dissections it was documented that the ZTN entered directly into the lacrimal gland with no communication with the LN. In 12 (36.4%) of the bisected heads, ZTN had both a direct connection into the gland and a communicating branch with the LN. In only one (3.0%) bisected head, ZTN communicated with the LN before entering the gland as it is commonly described in anatomy texts. Our study reveals that the ZTN usually takes a different course than is classically described in most anatomy textbooks. A greater understanding of the typical course these nerves take may help surgeons identify them more easily and avoid damaging them. © 2014 Wiley Periodicals, Inc.

  19. Sarcoidosis of the lacrimal gland as a first manifestation.

    PubMed

    Peralta-Gómez, M Y; Ávila-Ocampo, K A; Huerta-Velázquez, S; Rivera-Salgado, M I

    2018-04-01

    The first manifestation of sarcoidosis is usually at the pulmonary level. The case is described of a 40-year-old female patient, who presented with an increased volume of the lacrimal gland and mechanical ptosis of upper left eyelid as the first expression of this disease. The diagnosis of systemic sarcoidosis with primary presentation of the lacrimal gland was made after performing several immunological studies with negative results, imaging studies, and taking of glandular and lymph node biopsies. A favourable response was achieved with oral methotrexate treatment. Copyright © 2017 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Role of Orai1 and store-operated calcium entry in mouse lacrimal gland signalling and function.

    PubMed

    Xing, Juan; Petranka, John G; Davis, Felicity M; Desai, Pooja N; Putney, James W; Bird, Gary S

    2014-03-01

    Lacrimal glands function to produce an aqueous layer, or tear film, that helps to nourish and protect the ocular surface. Lacrimal glands secrete proteins, electrolytes and water, and loss of gland function can result in tear film disorders such as dry eye syndrome, a widely encountered and debilitating disease in ageing populations. To combat these disorders, understanding the underlying molecular signalling processes that control lacrimal gland function will give insight into corrective therapeutic approaches. Previously, in single lacrimal cells isolated from lacrimal glands, we demonstrated that muscarinic receptor activation stimulates a phospholipase C-coupled signalling cascade involving the inositol trisphosphate-dependent mobilization of intracellular calcium and the subsequent activation of store-operated calcium entry (SOCE). Since intracellular calcium stores are finite and readily exhausted, the SOCE pathway is a critical process for sustaining and maintaining receptor-activated signalling. Recent studies have identified the Orai family proteins as critical components of the SOCE channel activity in a wide variety of cell types. In this study we characterize the role of Orai1 in the function of lacrimal glands using a mouse model in which the gene for the calcium entry channel protein, Orai1, has been deleted. Our data demonstrate that lacrimal acinar cells lacking Orai1 do not exhibit SOCE following activation of the muscarinic receptor. In comparison with wild-type and heterozygous littermates, Orai1 knockout mice showed a significant reduction in the stimulated tear production following injection of pilocarpine, a muscarinic receptor agonist. In addition, calcium-dependent, but not calcium-independent exocytotic secretion of peroxidase was eliminated in glands from knockout mice. These studies indicate a critical role for Orai1-mediated SOCE in lacrimal gland signalling and function.

  1. Unilateral orbital lacrimal gland abscess in a horse.

    PubMed

    Greenberg, Shari M; Plummer, Caryn E; Brooks, Dennis E; Porter, Michael; Farina, Lisa L; Winter, Matthew D

    2011-01-01

    A 20-year-old Thoroughbred gelding presented for evaluation of a periorbital dorsal swelling of the left eye that had been intermittently present for 3 months. Upon ocular examination, a firm, non-painful swelling was identified under the upper eyelid in the region of the orbital lacrimal gland, and was noted to extend anteriorly from underneath the dorsal orbital rim. Ultrasonographic examination revealed a mixed echogenic mass along the dorsal orbital rim that followed the contour of the globe. CT scan showed a moderately contrast enhancing mass that was contiguous with the eyelid. Differential diagnoses included neoplasia, inflammatory lesions such as a granuloma, foreign body or abscess. Surgical exploration and excision of the mass revealed a lobular structure with a purulent center. Histopathology identified the mass as the orbital lacrimal gland with concurrent severe dacryoadenitis. Culture of the purulent center of the mass revealed beta-hemolytic Staphylococcus aureus. The patient was maintained on supportive care and antibiotic treatment based on sensitivity postoperatively. No recurrence was reported 40 months later. This paper aims to identify bacterial dacryoadenitis as a cause for unilateral periorbital swelling in the horse. Differential diagnoses for this presentation, as well as successful surgical management are discussed. To the author's knowledge, this is the first case of bacterial dacryoadenitis and subsequent abscessation of the orbital lacrimal gland in the horse. © 2011 American College of Veterinary Ophthalmologists.

  2. Detection of BrdU-label Retaining Cells in the Lacrimal Gland: Implications for Tissue Repair

    PubMed Central

    You, Samantha; Tariq, Ayesha; Kublin, Claire L.; Zoukhri, Driss

    2011-01-01

    The purpose of the present study was to determine if the lacrimal gland contains 5-bromo-2’-deoxyuridine (BrdU)-label retaining cells and if they are involved in tissue repair. Animals were pulsed daily with BrdU injections for 7 consecutive days. After a chase period of 2, 4, or 12 weeks, the animals were sacrificed and the lacrimal glands were removed and processed for BrdU immunostaining. In another series of experiments, the lacrimal glands of 12-week chased animals were either left untreated or were injected with interleukin 1 (IL-1) to induce injury. Two and half day post-injection, the lacrimal glands were removed and processed for BrdU immunostaining. After 2 and 4 week of chase period, a substantial number of lacrimal gland cells were BrdU+ (11.98 ± 1.84 and 7.95 ± 1.83 BrdU+ cells/mm2, respectively). After 12 weeks of chase, there was a 97% decline in the number of BrdU+ cells (0.38 ± 0.06 BrdU+ cells/mm2), suggesting that these BrdU-label retaining cells may represent slow-cycling adult stem/progenitor cells. In support of this hypothesis, the number of BrdU labeled cells increased over 7-fold during repair of the lacrimal gland (control: 0.41 ± 0.09 BrdU+ cells/mm2, injured: 2.91 ± 0.62 BrdU+ cells/mm2). Furthermore, during repair, among BrdU+ cells 58.2 ± 3.6 % were acinar cells, 26.4 ± 4.1% were myoepithelial cells, 0.4 ± 0.4% were ductal cells, and 15.0 ± 3.0% were stromal cells. We conclude that the murine lacrimal gland contains BrdU-label retaining cells that are mobilized following injury to generate acinar, myoepithelial and ductal cells. PMID:22101331

  3. Vision-related quality of life in patients undergoing silicone tube intubation for lacrimal passage obstructions.

    PubMed

    Kabata, Yoshiaki; Goto, Satoshi; Takahashi, Genichiro; Tsuneoka, Hiroshi

    2011-07-01

    To evaluate the changes in vision-related quality of life in patients with lacrimal passage obstructions undergoing silicone tube intubations. Prospective, consecutive, comparative, interventional case series. Forty-five patients with the chief complaint of epiphora diagnosed with complete and unilateral lacrimal passage obstructions were enrolled. Exclusion criteria included history of congenital nasolacrimal stenosis; lacrimal passage obstructions resulting from trauma, tumor, or chemotherapy; previous lacrimal passage surgery; and partial and functional nasolacrimal duct obstructions. Silicone tube intubation using a Nunchaku-style tube was performed under direct visualization with dacryoendoscope in all patients. Operations were considered as successful when the irrigating fluid could pass through the lacrimal passage and the disappearance of dye was observed in dye disappearance test and the patients' epiphora symptoms improved 3 months postoperatively. The 25-item National Eye Institute Visual Function Questionnaire (NEI VFQ-25) was self-administered in all patients preoperatively and 3 months postoperatively. Patients' preoperative and 3-months-postoperative NEI VFQ-25 scores were compared. Operations were successful in 40 patients (89%). Fully completed questionnaires were received from 32 patients (80%). Silicone tube intubation using a Nunchaku-style tube was associated with a significant improvement of the NEI VFQ-25 composite score (P = .0001), ocular pain score (P < .0001), and mental health score (P = .0003). Relief of epiphora by silicone tube intubation using a Nunchaku-style tube treatment significantly improved the vision-related quality of life in patients with lacrimal passage obstructions. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. An in vitro evaluation of various biomaterials for the development of a tissue-engineered lacrimal gland

    NASA Astrophysics Data System (ADS)

    Selvam, Shivaram

    The most common cause of ocular morbidity in developed countries is dry eye, many cases of which are due to lacrimal insufficiency. It has been established that lacrimal insufficiency results from processes caused by both immune-related and non-immune related events such as Sjogren's syndrome, Stevens-Johnson syndrome, chemical and thermal injuries and ocular cicatricial pemphigoid. Patients with these conditions would benefit from repair of their damaged lacrimal tissue by the creation of a replacement for the lacrimal gland. The new field of tissue engineering built on the interface between principles and methods of the life sciences with those of engineering to develop biocompatible materials has created the possibility for repairing or replacing damaged tissues. This thesis explores the use of tissue engineering principles for the development of a tissue-engineered lacrimal gland. This thesis also contributes to the development of a novel model for addressing lacrimal gland physiology and epithelial fluid transport. The first part of the research work focused on the evaluation of morphological and physiological properties of purified lacrimal gland acinar cells (pLGACs) cultured on various biopolymers: silicone, collagen I, poly-D,L-lactide-co-glycolide (PLGA; 85:15 and 50:50), and poly-L-lactic acid (PLLA) in the presence and absence of an extracellular matrix, MatrigelRTM. Results indicated that PLLA demonstrated the best support expression of acinar cell-like morphology. The second part demonstrated the ex vivo reconstitution of an electrophysiologically functional lacrimal gland tissue on porous polyester membrane scaffolds. Results showed that pLGACs were capable of establishing continuous epithelial monolayers that generate active ionic fluxes consistent with current models for Na +-dependent Cl-- secretion. The third part outlined the fabrication of porous PLLA membranes, the optimal biomaterial for culturing lacrimal epithelial cells. Microporous PLLA

  5. Assessment and Management of Proximal and Incomplete Symptomatic Obstruction of the Lacrimal Drainage System

    PubMed Central

    Kashkouli, Mohsen Bahmani; Pakdel, Farzad; Kiavash, Victoria

    2012-01-01

    Epiphora is a common complaint of patients who present to an Ophthalmology Clinic. In many cases, epiphora is due to an obstruction in the lacrimal drainage system. However, a subgroup of symptomatic patients with epiphora has a patent lacrimal drainage system. Such cases are usually termed ‘functional obstruction’ and / or ‘stenosis of the lacrimal drainage system’. Various etiologies and diagnostic and therapeutic approaches have been described in literature, which implies the lack of a standardized approach. This article will review the evolving diagnostic and therapeutic approaches in literature, and in the end, propose a paradigm in approaching this group of patients. PMID:22346116

  6. Development of Causative Treatment Strategies for Lacrimal Gland Insufficiency by Tissue Engineering and Cell Therapy. Part 2: Reconstruction of Lacrimal Gland Tissue: What Has Been Achieved So Far and What Are the Remaining Challenges?

    PubMed

    Massie, Isobel; Dietrich, Jana; Roth, Mathias; Geerling, Gerd; Mertsch, Sonja; Schrader, Stefan

    2016-10-01

    The lacrimal gland is located in the upper temporal compartment of the orbita, and along with the ocular surface, eye lids, and sensory and motor nerves forms the lacrimal functional unit (LFU). The LFU is responsible for producing, distributing, and maintaining the tear film in order to maintain a smooth, moist, and regular ocular surface epithelium such that appropriate refractive properties are achieved and the eyeball is protected against dust, debris, and pathogens. If the main lacrimal gland is impaired (due to either disease or injury), this balance is disrupted, and severe quantitative dry eye syndrome (DES) can develop. DES treatments remain palliative, with the most commonly used therapies being based on tear substitution, tear retention, and control of inflammation on the ocular surface. Causative treatments such as salivary gland transplantation have shown to reduce symptoms in very severe cases, however can cause problems on the ocular surface due to different properties of saliva and tears. Therefore, causative approaches for treating DES by regeneration or reconstruction of lacrimal gland tissue depending on disease severity seem highly appealing. This article reviews current approaches for in vitro reconstruction of lacrimal gland tissue. Finally, the limitations that must be overcome before a new, tissue-engineered therapy may be delivered to clinic will be discussed.

  7. Role of Epithelial–Mesenchymal Transition in Repair of the Lacrimal Gland after Experimentally Induced Injury

    PubMed Central

    You, Samantha; Avidan, Orna; Tariq, Ayesha; Ahluwalia, Ivy; Stark, Paul C.; Kublin, Claire L.

    2012-01-01

    Purpose. Ongoing studies demonstrate that the murine lacrimal gland is capable of repair after experimentally induced injury. It was recently reported that repair of the lacrimal gland involved the mobilization of mesenchymal stem cells (MSCs). These cells expressed the type VI intermediate filament protein nestin whose expression was upregulated during the repair phase. The aim of the present study was to investigate the roles of vimentin, a type III intermediate filament protein and a marker of epithelial–mesenchymal transition (EMT) in repair of the lacrimal gland. Methods. Injury was induced by direct injection of interleukin (IL)-1 into the exorbital lacrimal gland. MSCs were prepared from injured glands using tissue explants. Expression of vimentin and the transcription factor Snai1, a master regulator of EMT, was determined by RT-PCR, Western blotting analysis, and immunofluorescence. Results. These data show that vimentin expression, at both the mRNA and the protein levels, was upregulated during the repair phase (2–3 days postinjury) and returned to the control level when repair ended. Temporal expression of Snai1 mirrored that of vimentin and was localized in cell nuclei. Cultured MSCs isolated from injured lacrimal glands expressed Snai1 and vimentin alongside nestin and alpha smooth muscle actin (another biomarker of EMT). There was a strong positive correlation between Snai1 expression and vimentin expression. Conclusions. It was found that EMT is induced during repair of the lacrimal gland to generate MSCs to initiate repair, and that mesenchymal–epithelial transition is then activated to form acinar and ductal epithelial cells. PMID:22025566

  8. Lacrimal drainage-associated lymphoid tissue (LDALT): a part of the human mucosal immune system.

    PubMed

    Knop, E; Knop, N

    2001-03-01

    Mucosa-associated lymphoid tissue (MALT) specifically protects mucosal surfaces. In a previous study of the human conjunctiva, evidence was also found for the presence of MALT in the lacrimal sac. The present study, therefore, aims to investigate its morphology and topographical distribution in the human lacrimal drainage system. Lacrimal drainage systems (n = 51) obtained from human cadavers were investigated by clearing flat wholemounts or by serial sections of tissue embedded in paraffin, OCT compound, or epoxy resin. These were further analyzed by histology, immunohistochemistry, and electron microscopy. All specimens showed the presence of lymphocytes and plasma cells as a diffuse lymphoid tissue in the lamina propria, together with intraepithelial lymphocytes and occasional high endothelial venules (HEV). It formed a narrow layer along the canaliculi that became thicker in the cavernous parts. The majority of lymphocytes were T cells, whereas B cells were interspersed individually or formed follicular centers. T cells were positive for CD8 and the human mucosa lymphocyte antigen (HML-1). Most plasma cells were positive for IgA and the overlying epithelium expressed its transporter molecule secretory component (SC). Basal mucous glands were present in the lacrimal canaliculi and in the other parts accompanied by alveolar and acinar glands, all producing IgA-rich secretions. Primary and secondary lymphoid follicles possessing HEV were present in about half of the specimens. The term lacrimal drainage-associated lymphoid tissue (LDALT) is proposed here to describe the lymphoid tissue that is regularly present and belongs to the common mucosal immune system and to the secretory immune system. It is suggested that it may form a functional unit together with the lacrimal gland and conjunctiva, connected by tear flow, lymphocyte recirculation, and probably the neural reflex arc, and play a major role in preserving ocular surface integrity.

  9. Dynamic Ocular Surface and Lacrimal Gland Changes Induced in Experimental Murine Dry Eye

    PubMed Central

    Xiao, Bing; Wang, Yu; Reinach, Peter S.; Ren, Yueping; Li, Jinyang; Hua, Shanshan; Lu, Huihui; Chen, Wei

    2015-01-01

    Dry eye disease can be a consequence of lacrimal gland insufficiency in Sjögren’s Syndrome or increased tear film evaporation despite normal lacrimal gland function. To determine if there is a correlation between severity effects in these models and underlying pathophysiological responses, we compared the time dependent changes in each of these parameters that occur during a 6 week period. Dry eye was induced in 6-week-old female C57BL/6 mice by exposing them to an Intelligently Controlled Environmental System (ICES). Sixty mice were housed in ICES for 1, 2, 4 and 6 weeks respectively. Twelve were raised in normal environment and received subcutaneous injections of scopolamine hydrobromide (SCOP) 3 times daily for 5 days. Another sixty mice were housed in a normal environment and received no treatment. Corneal fluorescein staining along with corneal MMP-9 and caspase-3 level measurements were performed in parallel with the TUNEL assay. Interleukin-17(IL-17), IL-23, IL-6, IL-1, TNF-α, IFN-γ and TGF-β2 levels were estimated by real-time PCR measurements of conjunctival and lacrimal gland samples (LGs). Immunohistochemistry of excised LGs along with flow cytometry in cervical lymph nodes evaluated immune cell infiltration. Light and transmission electron microscopy studies evaluated LGs cytoarchitectural changes. ICES induced corneal epithelial destruction and apoptosis peaked at 2 weeks and kept stable in the following 4 weeks. In the ICES group, lacrimal gland proinflammatory cytokine level increases were much lower than those in the SCOP group. In accord with the lower proinflammatory cytokine levels, in the ICES group, lacrimal gland cytosolic vesicular density and size exceeded that in the SCOP group. ICES and SCOP induced murine dry eye effects became progressively more severe over a two week period. Subsequently, the disease process stabilized for the next four weeks. ICES induced local effects in the ocular surface, but failed to elicit lacrimal gland

  10. Dynamic ocular surface and lacrimal gland changes induced in experimental murine dry eye.

    PubMed

    Xiao, Bing; Wang, Yu; Reinach, Peter S; Ren, Yueping; Li, Jinyang; Hua, Shanshan; Lu, Huihui; Chen, Wei

    2015-01-01

    Dry eye disease can be a consequence of lacrimal gland insufficiency in Sjögren's Syndrome or increased tear film evaporation despite normal lacrimal gland function. To determine if there is a correlation between severity effects in these models and underlying pathophysiological responses, we compared the time dependent changes in each of these parameters that occur during a 6 week period. Dry eye was induced in 6-week-old female C57BL/6 mice by exposing them to an Intelligently Controlled Environmental System (ICES). Sixty mice were housed in ICES for 1, 2, 4 and 6 weeks respectively. Twelve were raised in normal environment and received subcutaneous injections of scopolamine hydrobromide (SCOP) 3 times daily for 5 days. Another sixty mice were housed in a normal environment and received no treatment. Corneal fluorescein staining along with corneal MMP-9 and caspase-3 level measurements were performed in parallel with the TUNEL assay. Interleukin-17(IL-17), IL-23, IL-6, IL-1, TNF-α, IFN-γ and TGF-β2 levels were estimated by real-time PCR measurements of conjunctival and lacrimal gland samples (LGs). Immunohistochemistry of excised LGs along with flow cytometry in cervical lymph nodes evaluated immune cell infiltration. Light and transmission electron microscopy studies evaluated LGs cytoarchitectural changes. ICES induced corneal epithelial destruction and apoptosis peaked at 2 weeks and kept stable in the following 4 weeks. In the ICES group, lacrimal gland proinflammatory cytokine level increases were much lower than those in the SCOP group. In accord with the lower proinflammatory cytokine levels, in the ICES group, lacrimal gland cytosolic vesicular density and size exceeded that in the SCOP group. ICES and SCOP induced murine dry eye effects became progressively more severe over a two week period. Subsequently, the disease process stabilized for the next four weeks. ICES induced local effects in the ocular surface, but failed to elicit lacrimal gland

  11. P63 Positive Mucoepidermoid Tumor of the Lacrimal Sac with Associated Papilloma.

    PubMed

    Iordanous, Yiannis; Belrose, Jillian C; Cadieux, Dani C; Chakrabarti, Subrata; Farmer, James P; Allen, Larry H

    2015-01-01

    We report a case of a 44-year-old man who presented with a left medial canthal mass and epiphora. Imaging was suggestive of a mass continuous with the nasolacrimal sac. Subsequent surgical exploration revealed a mass adherent to bone with invasion of the lacrimal system. Histological examination revealed a squamous/transitional cell papilloma overlying a low-grade mucoepidermoid carcinoma (MEC). Complete surgical resection was completed and pathology confirmed the diagnosis. This is the first case in which a MEC has been reported concurrently with an overlying papilloma, providing support for the hypothesis that MECs arise from papillomas in the lacrimal sac. Additionally, the tissue stained positive for p63, which is congruent with MEC immunoreactivity in the salivary gland. The description of these unique histopathological findings may assist in definitive diagnosis and improve our understanding of the pathophysiology underlying lacrimal sac MEC tumors.

  12. Granulomatosis with polyangiitis confined to lacrimal gland, a case report.

    PubMed

    Zuazo, F; González, M; Abdala, A; Olvera-Morales, O; Monroy, M H; Rodríguez-Reyes, A; Tovilla-Canales, J L; Nava-Castañeda, Á

    2017-11-01

    A 43 year-old woman consulted due to 2 months of swelling on the superolateral side of the left orbit, with pain and erythema. An excisional biopsy was performed that revealed vasculitis with polyangiitis of the lacrimal gland. A systemic study showed that no other system was compromised. Orbital involvement occurs in up to 60% of patients with granulomatosis with polyangiitis. The involvement of the lacrimal gland is rare and often unilateral. Serological tests are generally negative, both in initial stages, as in localized forms of the disease. Copyright © 2016 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Long-Term Outcomes of Eye-Sparing Surgery for Adenoid Cystic Carcinoma of Lacrimal Gland.

    PubMed

    Han, Jisang; Kim, Yoon-Duck; Woo, Kyung In; Sobti, Deepak

    This study's primary purpose is to assess the long-term outcomes of patients who have undergone eye-sparing surgery and adjuvant radiotherapy for adenoid cystic carcinoma of the lacrimal gland. In this retrospective analysis, clinical records were reviewed of all patients diagnosed with adenoid cystic carcinoma of the lacrimal gland, at a single institution, between March 1998 and November 2012. Ten patients were identified as having undergone eye-sparing surgery and adjuvant radiotherapy for adenoid cystic carcinoma of the lacrimal gland. Preoperative radiographic findings, treatment modalities, histological results, and patient outcomes were analyzed. There were 6 male and 4 female patients. The patients' tumors were staged according to the 8th American Joint Committee on Cancer staging system, and were as follows: 1 patient was classified as T1aN0M0; 6 patients were classified as T2aN0M0; 1 patient was classified as T2cN0M0; 2 patients were classified as T3aN0M0. All patients had a histologically confirmed diagnosis of lacrimal gland adenoid cystic carcinoma, which was confined to the orbit, and was without extension into adjacent bone marrow or other organs. All patients underwent eye-sparing tumor excision followed by postoperative radiotherapy, with a median dose of 6000 cGy (range: 5000-6600 cGy). At the last follow up, 8 patients were alive without evidence of disease. One patient was deceased at 58 months post-surgery, due to esophageal carcinoma; this was unrelated to the lacrimal gland tumor. The final patient experienced tumor recurrence in the medial orbit 53 months post-surgery, and exenteration was performed. This patient was alive, without disease recurrence, at 90 months following exenteration. The median follow-up time was 89.5 months (range: 37-217 months). Systemic metastasis did not occur in any patient. Eye-sparing surgery and adjuvant radiotherapy have demonstrated favorable local control and long-term survival outcomes in patients with orbit

  14. Bilateral congenital lacrimal fistulas in an adult as part of ectrodactyly-ectodermal dysplasia-clefting syndrome: A rare anomaly.

    PubMed

    Ghosh, Debangshu; Saha, Somnath; Basu, Sumit Kumar

    2015-10-01

    Ectrodactyly-ectodermal dysplasia and clefting syndrome or "Lobster claw" deformity is a rare congenital anomaly that affects tissues of ectodermal and mesodermal origin. Nasolacrimal duct (NLD) obstruction with or without atresia of lacrimal passage is a common finding of such a syndrome. The authors report here even a rarer presentation of the syndrome which manifested as bilateral NLD obstruction and lacrimal fistula along with cleft lip and palate, syndactyly affecting all four limbs, mild mental retardation, otitis media, and sinusitis. Lacrimal duct obstruction and fistula were managed successfully with endoscopic dacryocystorhinostomy (DCR) which is a good alternative to lacrimal probing or open DCR in such a case.

  15. New experimental method to study acid/base transporters and their regulation in lacrimal gland ductal epithelia.

    PubMed

    Tóth-Molnár, Edit; Venglovecz, Viktória; Ozsvári, Béla; Rakonczay, Zoltán; Varró, András; Papp, Julius G; Tóth, András; Lonovics, János; Takács, Tamás; Ignáth, Imre; Iványi, Béla; Hegyi, Péter

    2007-08-01

    The main function of the lacrimal gland is to produce the most aqueous component of the tear film covering the surfaces of the cornea and the conjunctiva. Studies have been conducted that characterize the mixed fluid and protein secretion of isolated acini, but no methods have been developed to characterize lacrimal gland ductal cell (LGDC) secretion. Secretory mechanisms of ductal epithelia may play physiological roles in the maintenance of the standard environments for the cornea and the conjunctiva. In this study, the authors developed a rapid method to isolate large quantities of intact lacrimal ducts. The preparation of isolated intact lacrimal gland ducts for the first time enabled the performance of real-time functional experiments on cleaned ducts. Electron microscopy and fluorescence measurements were used to evaluate the viability of lacrimal ducts. Fluorescence measurements showed that LGDCs express functionally active Na(+)/H(+) exchanger (NHE) and Cl(-)/HCO(3)(-) exchanger (AE). Parasympathomimetic stimulation by carbachol stimulated NHE and AE through the elevation of intracellular calcium concentration. This mechanism can play a role in the regulation of ion and water secretion by LGDCs. The authors have described a lacrimal gland duct isolation technique in which the intact ducts remain viable and the role of duct cells in tear film secretion can be characterized. These data combined with the novel isolation facilitated understanding of the regulation mechanisms of ductal cell secretion at cellular and molecular levels under normal and pathologic conditions.

  16. Interaction of corneal nociceptive stimulation and lacrimal secretion.

    PubMed

    Situ, Ping; Simpson, Trefford L

    2010-11-01

    To investigate the interaction between corneal stimuli at different positions and tear secretion and to establish relationships between nociceptive stimuli detection thresholds and stimulated tearing. Using a computerized Belmonte-esthesiometer, mechanical and chemical stimuli, from 0% to 200% of the threshold in 50% steps, were delivered (in random order) to the central and peripheral (approximately 2-mm inside the limbus) cornea during four separate sessions to 15 subjects. Immediately after each stimulus, tear meniscus height (TMH) was measured using optical coherence tomography to quantify the amount of lacrimal secretion, and subjects reported whether they felt tears starting to accumulate in their eyes. Thresholds (50% detection) for detection of tearing were estimated. TMH increased with increasing stimulus intensity (P < 0.05), and the overall increase was higher with central stimulation than with peripheral stimulation (P < 0.05). The changes in TMH with threshold-scaled stimulus intensity depended on test location (P < 0.05) and stimulus modality (P < 0.05). The maximum intensity of mechanical stimulation of the central cornea induced the greatest TMH (all P < 0.05). For chemical stimulation, the stimulus intensity required to induce detectable tearing was higher than that required to detect a stimulus and higher in the periphery than at the center (all P < 0.05). Noxious mechanical and chemical stimuli evoked measurable tear secretion, with central corneal mechanical stimulation evoking the strongest lacrimation reflex. Central mechanical corneal stimulation is the most effective stimulus-position pairing and appears to be the major sensory driving force for reflex tear secretion by the lacrimal functional unit.

  17. Mitochondria-targeted antioxidant SkQ1 reduces age-related alterations in the ultrastructure of the lacrimal gland

    PubMed Central

    Bakeeva, Lora E.; Eldarov, Chupalav M.; Vangely, Irina M.; Kolosova, Nataliya G.; Vays, Valeriya B.

    2016-01-01

    Dry eye syndrome is an eye disorder affecting many people at an old age. Because dry eye syndrome is accelerated by aging, a useful approach to the prevention of this syndrome may be an intervention into the aging process. Previously, we showed that the mitochondria-targeted antioxidant SkQ1 delays manifestations of aging and inhibits the development of age-related diseases including dry eye syndrome. Nevertheless, the link between SkQ1's effects and its suppression of age-related changes in the lacrimal gland remains unclear. Here we demonstrated that dietary supplementation with SkQ1 (250 nmol/[kg body weight] daily) starting at age 1.5 months significantly alleviated the pathological changes in lacrimal glands of Wistar rats by age 24 months. By this age, lacrimal glands underwent dramatic deterioration of the ultrastructure that was indicative of irreversible disturbances in these glands' functioning. In contrast, in SkQ1-treated rats, the ultrastructure of the lacrimal gland was similar to that in much younger rats. Morphometric analysis of electron-microscopic specimens of lacrimal glands revealed the presence of numerous secretory granules in acinar cells and a significant increase in the number of operating intercalary ducts. Our results confirm that dietary supplementation with SkQ1 is a promising approach to healthy ageing and to prevention of aberrations in the lacrimal gland that underlie dry eye syndrome. PMID:27852065

  18. Expression profiles of aquaporins in rat conjunctiva, cornea, lacrimal gland and Meibomian gland.

    PubMed

    Yu, Dongfang; Thelin, William R; Randell, Scott H; Boucher, Richard C

    2012-10-01

    The aim of the study was to elucidate aquaporin (AQP) family member mRNA expression and protein expression/localization in the rat lacrimal functional unit. The mRNA expression of all rat AQPs (AQP0-9, 11-12) in palpebral, fornical, and bulbar conjunctiva, cornea, lacrimal gland, and Meibomian gland was measured by Reverse Transcriptase-Polymerase Chain Reaction (RT-PCR) and real time RT-PCR. Antibodies against AQP1, 3, 4, 5, 9, and 11 were used in Western blotting and immunohistochemistry to determine protein expression and distribution. Our study demonstrated characteristic AQP expression profiles in rat ocular tissues. AQP1, 3, 4, 5, 8, 9, 11, and 12 mRNA were detected in conjunctiva. AQP0, 1, 2, 3, 4, 5, 6, 11, and 12 mRNA were expressed in cornea. AQP0, 1, 2, 3, 4, 5, 7, 8, and 11 mRNA were detected in lacrimal gland. AQP1, 3, 4, 5, 7, 8, 9, 11, and 12 mRNA were identified in Meibomian gland. By Western blot, AQP1, 3, 5, and 11 were detected in conjunctiva; AQP1, 3, 5, and 11 were identified in cornea; AQP1, 3, 4, 5, and 11 were detected in lacrimal gland; and AQP1, 3, 4, 5, 9, and 11 were present in Meibomian gland. Immunohistochemistry localized AQPs to distinct sites in the various tissues. This study rigorously analyzed AQPs expression and localization in rat conjunctiva, cornea, lacrimal gland, and Meibomian gland tissues. Our findings provide a comprehensive platform for further investigation into the physiological or pathophysiological relevance of AQPs in ocular surface. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. An alternative method of closed silicone intubation of the lacrimal system.

    PubMed

    Henderson, P N; McNab, A A

    1996-05-01

    An alternative method of closed lacrimal intubation is described, the basis of which is to place the end of a piece of silicone tubing over the end of a small-diameter metal introducer, stretch the silicone tubing back along the introducer, and then pass the introducer together with the tubing through the lacrimal system into the nasal cavity. The tubing is visualized in the inferior meatus, from where it is retrieved, and then the introducer is withdrawn. The other end of the tubing is passed in a similar fashion. The technique is easily mastered, inexpensive, and less traumatic than other described techniques.

  20. Influence of ribosomal protein L39-L in the drug resistance mechanisms of lacrimal gland adenoid cystic carcinoma cells.

    PubMed

    Ye, Qing; Ding, Shao-Feng; Wang, Zhi-An; Feng, Jie; Tan, Wen-Bin

    2014-01-01

    Cancer constitutes a key pressure on public health regardless of the economy state in different countries. As a kind of highly malignant epithelial tumor, lacrimal gland adenoid cystic carcinoma can occur in any part of the body, such as salivary gland, submandibular gland, trachea, lung, breast, skin and lacrimal gland. Chemotherapy is one of the key treatment techniques, but drug resistance, especially MDR, seriously blunts its effects. As an element of the 60S large ribosomal subunit, the ribosomal protein L39-L gene appears to be documented specifically in the human testis and many human cancer samples of different origins. Total RNA of cultured drug-resistant and susceptible lacrimal gland adenoid cystic carcinoma cells was seperated, and real time quantitative RT-PCR were used to reveal transcription differences between amycin resistant and susceptible strains of lacrimal gland adenoid cystic carcinoma cells. Viability assays were used to present the amycin resistance difference in a RPL39-L transfected lacrimal gland adenoid cystic carcinoma cell line as compared to control vector and null-transfected lacrimal gland adenoid cystic carcinoma cell lines. The ribosomal protein L39-L transcription level was 6.5-fold higher in the drug-resistant human lacrimal gland adenoid cystic carcinoma cell line than in the susceptible cell line by quantitative RT-PCR analysis. The ribosomal protein L39-L transfected cells revealed enhanced drug resistance compared to plasmid vector-transfected or null-transfected cells as determined by methyl tritiated thymidine (3H-TdR) incorporation. The ribosomal protein L39-L gene could possibly have influence on the drug resistance mechanism of lacrimal gland adenoid cystic carcinoma cells.

  1. Corneal Sensitivity Following Lacrimal Gland Excision in the Rat

    PubMed Central

    Meng, Ian D.; Barton, Stephen T.; Mecum, Neal E.; Kurose, Masayuki

    2015-01-01

    Purpose. Dry eye disease (DED) produces ocular pain and irritation, yet a detailed characterization of ocular sensitivity in a preclinical model of DED is lacking. The aim of the present study was to assess nociceptive behaviors in an aqueous tear deficiency model of DED in the rat. Methods. Spontaneous blinking, corneal mechanical thresholds, and eye wipe behaviors elicited by hypertonic saline (5.0 M) were examined over a period of 8 weeks following the unilateral excision of either the exorbital lacrimal gland or of the exorbital and infraorbital lacrimal glands, and in sham surgery controls. The effect of topical proparacaine on spontaneous blinking and of systemic morphine (0.5–3.0 mg/kg, subcutaneous [SC]) on spontaneous blinking and eye wipe responses were also examined. Results. Lacrimal gland excision resulted in mechanical hypersensitivity and an increase in spontaneous blinking in the ipsilateral eye over an 8-week period that was more pronounced after infra- and exorbital gland excision. The time spent eye wiping was also enhanced in response to hypertonic saline (5.0 M) at both 1- and 8-week time-points, but only in infra- and exorbital gland excised animals. Morphine attenuated spontaneous blinking, and the response to hypertonic saline in dry eye animals and topical proparacaine application reduced spontaneous blinking down to control levels. Conclusions. These results indicate that aqueous tear deficiency produces hypersensitivity in the rat cornea. In addition, the increase in spontaneous blinks and their reduction by morphine and topical anesthesia indicate the presence of persistent irritation elicited by the activation of corneal nociceptors. PMID:26024120

  2. [The expression of MMP-2 and MMP-9 in adenoid cystic carcinoma of lacrimal gland].

    PubMed

    Zhang, Lei; Zhang, Hong; Song, Guo-xiang; Lin, Ting-ting; Xu, Guang-chang; Zhu, Li-min

    2013-01-01

    To investigate the expression of matrix metal proteinase (MMP)-2 and MMP-9 in adenoid cystic carcinoma of lacrimal gland as well as their relation with biological behaviour of adenoid cystic carcinoma. Experimental study. The research objects were 60 cases of adenoid cystic carcinoma of lacrimal gland which were collected from No.2 Hospital of Tianjin Medical University from January 1991 to Jule 2011. There were 25 males and 35 females aged from 29 to 42 years. Based on histological revision, there were 36 cases of cribriform-tubular subtype and 24 cases of solid subtype. Forty-five cases were primary lesions and 15 cases were recurrent lesions. Ten samples of normal lacrimal gland around polymorphic adenoma were selected as the control group. The expression of CD105, MMP-2 and MMP-9 were evaluated by immunohistochemistry. The microvessel density (MVD) was defined by expression of CD105. One way ANOVA, χ(2)-test and spearman correlation test were used to analyzed the data. The number of MVD [(17.71 ± 5.63)/100 folds field of vision] and the positive rates of MMP-2 (45.0%, 27/60) and MMP-9 (55.0%, 33/60) in the samples of adenoid cystic carcinoma of lacrimal gland were higher than those in the normal lacrimal gland [the number of MVD was (0.70 ± 0.95)/100 folds field of vision, the expressions of MMP-2 and MMP-9 were negative] (t' = 2.039, P < 0.05; χ(2) = 5.550, P < 0.05; χ(2) = 8.315, P < 0.01), the solid subtypes had more MVD [(26.12 ± 5.32)/100 folds field of vision] and higher positive rates of MMP-2 (62.5%, 15/24) and MMP-9 (79.2%, 19/24) than the cribriform-tubular subtypes (t' = 2.060, P < 0.05; χ(2) = 4.950, P < 0.05; χ(2) = 9.439, P < 0.05); the recurrent lesions had more MVD and higher positive rate of MMP-2 and MMP-9 than the primary lesions (t' = 2.129, P < 0.05; χ(2) = 9.899, P < 0.05; χ(2) = 8.103, P < 0.05). The number of MVD in ACC of lacrimal gland patients was correlated with the positive rate of MMP-2 and MMP-9 respectively (rs = 0

  3. A rare case of late solitary vertebral metastasis from an adenoid cystic carcinoma of the lacrimal gland.

    PubMed

    Ahmed, Awaiz; Rajankulam Ganesan, Satish Kannan; Haleem, Shahnawaz; Nicoll, James

    2017-06-13

    Adenoid cystic carcinoma of the lacrimal gland is one among the common malignancies affecting the lacrimal gland. However, overall, it is a rare condition. It has a rather poor prognosis with local recurrence and distant haematological metastasis which are invariably multiple. We present a rare case of a 51-year-old woman who presented with localised lower thoracic pain with collapse of the T10 vertebral body, which turned out be a solitary late metastasis from her previously treated lacrimal gland tumour. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. Lacrimal gland-derived IL-22 regulates IL-17-mediated ocular mucosal inflammation

    PubMed Central

    Ji, Yong Woo; Mittal, Sharad K.; Hwang, Ho Sik; Chang, Eun-Ju; Lee, Joon H.; Seo, Yuri; Yeo, Areum; Noh, Hyemi; Lee, Hye Sun; Chauhan, Sunil K.; Lee, Hyung Keun

    2016-01-01

    Inflammatory damage of mucosal surface of the eye is a hallmark of dry eye disease (DED), and in severe cases can lead to significant discomfort, visual impairment, and blindness. DED is a multifactorial autoimmune disorder with a largely unknown pathogenesis. Using a cross-sectional patient study and a well-characterized murine model of DED, herein we investigated the immunoregulatory function of interleukin-22 (IL-22) in the pathogenesis of DED. We found that IL-22 levels were elevated in lacrimal fluids of DED patients and inversely correlated with severity of disease. Acinar cells of the lacrimal glands, not inflammatory immune cells, are the primary source of IL-22, which suppresses inflammation in ocular surface epithelial cells upon desiccating stress. Moreover, loss of function analyses using IL-22 knock-out mice demonstrated that IL-22 is essential for suppression of ocular surface infiltration of Th17 cells and inhibition of DED induction. Our novel findings elucidate immunoregulatory function of lacrimal gland-derived IL-22 in inhibiting IL-17-mediated ocular surface epitheliopathy in DED thus making IL-22 a new relevant therapeutic target. PMID:28051088

  5. Double silicone tube intubation for the management of partial lacrimal system obstruction.

    PubMed

    Demirci, Hakan; Elner, Victor M

    2008-02-01

    To evaluate the effectiveness of double silicone intubation for the management of partial lacrimal drainage system obstruction in adults. Observational retrospective case series. Twenty-four eyes of 18 consecutive adult patients with partial lacrimal system obstruction managed at the University of Michigan. Retrospective review of symptoms and signs, duration of silicone intubation, and complications. Resolution of tearing. Preoperative tearing, negative Jones I testing, positive Jones II testing, and resistance to positive-pressure irrigation were present in all eyes (100%). The first silicone tube was removed after a mean of 11+/-7 months, and the second tube after 16+/-6 months. Postoperatively, at a mean of 21+/-9 months after removal of both tubes, tearing remained resolved in 19 eyes (79%) and remained improved in 2 eyes (8%). In eyes with resolved tearing, Jones I testing became positive, and there was no resistance to positive-pressure irrigation. Persistent tearing in 3 eyes (13%) required treatment with external dacryocystorhinostomy. The only complication was peripunctal pyogenic granulomas in 2 eyes. Double silicone intubation is an effective minimally invasive technique for treatment of partial lacrimal system obstruction in adults.

  6. Acquired fistula of the lacrimal sac and laisser-faire approach. Description of the natural history of acquired fistulas between the lacrimal sac and the skin occurring before planned endonasal dacryocystorhinostomy (DCR) and without any treatment of the fistula.

    PubMed

    Pison, A; Fau, J-L; Racy, E; Fayet, B

    2016-10-01

    The formation of a fistula between the lacrimal sac and the skin is a classic outcome of resistant lacrimal sac abscesses. There is currently no consensus about treatment in such cases. The goal of this study was to describe the natural history of acquired fistulas between the lacrimal sac and the skin, occurring before planned endonasal dacryocystorhinostomy (DCR) and without any treatment of the fistula. This prospective study was only descriptive and included patients between 1999 and 2012. The patients included were adults with a nasolacrimal duct (NLD) obstruction that was planned to be treated with endonasal DCR. A resistant lacrimal sac abscess appeared a few days before the planned surgery, and fistulized spontaneously despite medical treatment. The surgery was not delayed. The DCR was endoscopic. Nothing was done for the fistula. Its healing was spontaneous. The exclusion criteria were the following: congenital fistulas, post-traumatic and/or iatrogenic fistulas, fistulas which had regressed by the day of the surgery, postoperative follow-up less than 5 months, post-traumatic and/or iatrogenic fistulas, any history of previous DCR or any other lacrimal surgery, children. Twenty adults (25 cases) were included in the analysis. Mean age was 79 years old (from 41 to 90). The mean follow-up was 41 months (from 5 to 108 months). The fistula spontaneously disappeared in all cases, less than one month after it had appeared and in a permanent fashion. No unsightly scar developed. Spontaneously acquired fistulas between the lacrimal sac and the skin may occur in the natural course of abscessed acute dacryocystitis. Our study showed spontaneous healing of the fistula post-endoscopic DCR. Fistula excision in fistulous acute dacryocystitis does not seem essential to its healing. The laisser-faire approach appears adequate for aesthetic outcomes as well as for functional outcomes of DCR. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  7. Computed tomographic imaging characteristics of the normal canine lacrimal glands

    PubMed Central

    2014-01-01

    Background The canine lacrimal gland (LG) and accessory lacrimal gland of the third eyelid (TEG) are responsible for production of the aqueous portion of the precorneal tear film. Immune-mediated, toxic, neoplastic, or infectious processes can affect the glands directly or can involve adjacent tissues, with secondary gland involvement. Disease affecting these glands can cause keratoconjunctivitis sicca, corneal ulcers, and loss of vision. Due to their location in the orbit, these small structures are difficult to evaluate and measure, making cross-sectional imaging an important diagnostic tool. The detailed cross-sectional imaging appearance of the LG and TEG in dogs using computed tomography (CT) has not been reported to date. Results Forty-two dogs were imaged, and the length, width, and height were measured and the volume calculated for the LGs & TEGs. The glands were best visualized in contrast-enhanced CT images. The mean volume of the LG was 0.14 cm3 and the TEG was 0.1 cm3. The mean height, width, and length of the LG were, 9.36 mm, 4.29 mm, and 9.35 mm, respectively; the corresponding values for the TEG was 2.02 mm, 9.34 mm, and 7.90 mm. LG and TEG volume were positively correlated with body weight (p < 0.05). Conclusions Contrast-enhanced CT is a valuable tool for noninvasive assessment of canine lacrimal glands. PMID:24886364

  8. Predictors of Silicone Tube Intubation Success in Patients with Lacrimal Drainage System Stenosis.

    PubMed

    Baek, Ji Sun; Lee, Saem; Lee, Jung Hye; Choi, Hye Sun; Jang, Jae Woo; Kim, Sung Joo

    2016-06-01

    To evaluate prognostic factors affecting silicone tube intubation outcomes in Asian patients with lacrimal drainage system stenosis. A retrospective review was conducted on the medical records of 822 patients (1,118 eyes) who had undergone silicone tube intubation to treat lacrimal drainage system stenosis between January 2011 and December 2012. Patients were divided into two groups: a success group and a failure group. Success was defined as the disappearance of epiphora symptoms, normalization of tear meniscus height, and the easy passage of fluid without resistance on the postoperative syringing test. Patient and ocular parameters were compared between the success and failure groups. A total of 994 eyes of 727 patients were included in analyses. Patients had a mean follow-up period of 34.11 ± 18.70 weeks. Silicone tube intubation was successful in 67.2% of participants. Significant differences between the success and failure groups were found for age (p < 0.001), history of ipsilateral facial palsy (p = 0.028), follow-up period (p < 0.001), and degree of passage on the preoperative syringing test (p = 0.001). Only age (p < 0.001) and degree of passage on the preoperative syringing test (p = 0.002) remained significantly associated with silicone tube intubation success in multivariate analysis. Age was negatively associated with silicone tube intubation success in patients with lacrimal drainage system stenosis. The success rate was higher in patients who showed easy passage of fluid without resistance on the preoperative syringing test. These factors should be considered by surgeons planning silicone tube intubation in patients with lacrimal drainage system stenosis.

  9. External dacryocystorhinostomy for the treatment of epiphora in patients with patent but non-functioning lacrimal systems.

    PubMed

    Peter, Neena M; Pearson, Andrew R

    2010-02-01

    To assess the outcome of external dacryocystorhinostomies (DCRs) in patients with patent but non-functional lacrimal drainage systems and to identify any preoperative clinical or dacryocystography (DCG) and lacrimal scintigraphy (LS) factors associated with successful surgery. A retrospective study of 46 DCRs with silicone intubation performed for patients with epiphora associated with a clinically patent lacrimal drainage system. All patients underwent preoperative DCG and LS which were evaluated for presence, site and severity of delayed clearance. DCGs were also evaluated for reflux and anatomical abnormalities. Postoperative success was determined by subjective resolution of epiphora. Patients with persistent symptoms were offered Lester Jones Tube (LJT) insertion after establishment of a patent anastomosis to syringing and normal ostium on nasal endoscopy. Statistical analysis was performed using the chi2 and Fisher exact tests to determine whether there was any association between surgical outcome and preoperative resistance to lacrimal syringing, DCG and LS findings. 29 cases (63%) reported subjective surgical success after 11 months' average follow-up. There was a statistically significant association between increased resistance to syringing preoperatively and successful DCR (p=0.012). Of the 17 eyes that failed, all had patent anastomoses, and seven went on to have LJT insertion with complete resolution of symptoms. The majority of patients with patent but non-functional lacrimal drainage systems will be helped by DCR surgery, with greater success rates in those with significant reflux on preoperative syringing. For patients with residual epiphora, functional success can reach 100% with subsequent LJT insertion.

  10. Normative dimensions and symmetry of the lacrimal drainage system on dacryocystography: statistical analysis of morphometric characteristics.

    PubMed

    Horsburgh, A; Massoud, T F

    2013-05-01

    Asymmetric lacrimal flow occurs in females more than males. We hypothesised that the normal lacrimal drainage system (LDS) may show subtle left-right asymmetry in morphometry when imaged on dacryocystography (DCG). We retrospectively reviewed 60 normal bilateral LDSs.Images were analysed for 7 parameters: (1) combined length of either the superior or inferior canaliculus plus common canaliculus, (2) angle of insertion of common canaliculus into lacrimal sac (LS), (3, 4) length and width of the LS, (5) length of the naso lacrimal duct (NLD), and (6, 7) width of proximal and distal NLD. We tested the effect of independent variables (age, gender, and side) on each dependent variable (length, width, or angle) using regression analysis. We used a Studentt-test for independent samples to statistically compare bilateral LDSs. Patient median age was 62 years, and male:female ratio was 27:73. Mean dimensions and angles for all LDSs were: (1) 14.5 mm, (2) 57°,(3) 11.6 mm, (4) 2.1 mm, (5) 20.7 mm, (6) 1.4 mm, and (7) 1.8 mm. No independent variable affected variation in length, width, or angle. No significant difference emerged between dimensions of right and left LDSs in both sexes. A degree of affective lateralisation in the brain is known to result in lacrimal flow asymmetry after mood manipulation. We show that this is not reflected in LDS anatomy. Moreover, our detailed morphometric data can aid in therapeutic planning of LDS luminal procedures, especially when DCG images of one LDS are used as a road map for contralateral interventions.

  11. Primary lymphocytic lymphoma of lacrimal gland.

    PubMed

    Romero-Caballero, M D; Lozano-García, I; Gómez-Molina, C; Gil-Liñán, A I; Arcas, I

    2017-02-01

    We report a case of primary small-cell lymphocytic lacrimal gland lymphoma in a male diagnosed with primary antiphospholipid syndrome. These rare lymphomas are usually presented in the clinic as disseminations secondary to chronic lymphocytic leukaemia, and the primary site is rare in the orbit. Non-Hodgkin lymphomas are a heterogeneous group of tumours. Although treatment in the IE stage is usually radiotherapy, due to its association with antiphospholipid syndrome, systemic treatment with rituximab was administered. Copyright © 2016 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. Mechanisms Involved in Injury and Repair of the Murine Lacrimal Gland: Role of Programmed Cell Death and Mesenchymal Stem Cells

    PubMed Central

    Zoukhri, Driss

    2011-01-01

    The non-keratinized epithelia of the ocular surface are constantly challenged by environmental insults, such as smoke, dust, and airborne pathogens. Tears are the sole physical protective barrier for the ocular surface. Production of tears in inadequate quantity or of inadequate quality results in constant irritation of the ocular surface, leading to dry eye disease, also referred to as keratoconjunctivitis sicca (KCS). Inflammation of the lacrimal gland, such as occurs in Sjögren’s syndrome, sarcoidosis, chronic graft versus-host disease, and other pathological conditions, results in inadequate secretion of the aqueous layer of the tear film, and is a leading cause of dry eye disease. The hallmarks of lacrimal gland inflammation are the presence of immune cell infiltrates, loss of acinar epithelial cells (the secreting cells), and increased production of proinflammatory cytokines. To date, the mechanisms leading to acinar cell loss and the associated decline in lacrimal gland secretion are still poorly understood. It is also not understood why the remaining lacrimal gland cells are unable to proliferate in order to regenerate a functioning lacrimal gland. This article reviews recent advances in exocrine tissue injury and repair, with emphasis on the roles of programmed cell death and stem/progenitor cells. PMID:20427009

  13. Diagnostic imaging of the nasolacrimal drainage system. Part I. Radiological anatomy of lacrimal pathways. Physiology of tear secretion and tear outflow.

    PubMed

    Maliborski, Artur; Różycki, Radosław

    2014-04-17

    Excessive watering of the eye is a common condition in ophthalmological practice. It may be the result of excessive production of tear fluid or obstruction and insufficiency of efferent tear pathways. The differentiation between obstruction and insufficiency of the lacrimal pathways is still clinically questionable. In the diagnostic process it is necessary to perform clinical tests and additional diagnostic imaging is often needed. Dacryocystography, with or without the extension of the dynamic phase or subtraction option, still remains the criterion standard for diagnostic imaging of the lacrimal obstruction. It may help to clarify the cause and exact place of the obstruction and provide information for further management, especially surgical treatment. Increasingly, new techniques are used in diagnostic imaging of the lacrimal tract, such as computed tomography, magnetic resonance, and isotopic methods. Adequate knowledge of the anatomy and physiology of the lacrimal system and the secretion and outflow of tears is the basis for proper diagnostic imaging. The purpose of this paper is to present the exact anatomy of the lacrimal system, with particular emphasis on the radiological anatomy and the current state of knowledge about the physiology of tear secretion and drainage.

  14. Cardiobacterium hominis-induced acute dacryocystitis and lacrimal abscess

    PubMed Central

    Manderwad, Guru Prasad; Kodiganti, Manjulatha; Ali, Mohammad Javed

    2014-01-01

    Cardiobacterium hominis is a member of the HACEK (Haemophilus sp., Actinobacillus actinomycetemcomitans, C. hominis, Eikenella corrodens, and Kingella kingae) group commonly associated with endocarditits and is normally present in the respiratory tract. We describe the first case of acute dacryocystitis with lacrimal abscess caused by C. hominis along with a brief review of the literature. The patient responded to oral and topical ciprofloxacin after incision and drainage and awaits dacryocystorhinostomy. PMID:24008805

  15. Production and localization of Muc4/sialomucin complex and its receptor tyrosine kinase ErbB2 in the rat lacrimal gland.

    PubMed

    Arango, M E; Li, P; Komatsu, M; Montes, C; Carraway, C A; Carraway, K L

    2001-11-01

    To show the presence and forms of sialomucin complex (rat Muc4) and receptor tyrosine kinase ErbBs in the rat lacrimal gland and analyze for complexes of ErbB2 and its ligand Muc4. Northern blot analyses were used to identify sialomucin complex/Muc4 (SMC/Muc4) mRNA in rat lacrimal gland. Immunoblot analyses were performed to detect SMC/Muc4 and ErbBs. Sequential immunoprecipitation and immunoblot analyses were used to differentiate membrane and soluble forms of the SMC/Muc4 transmembrane subunit ASGP-2. Methacarn-fixed, paraffin-embedded sections of lacrimal glands from female adult rats were immunocytochemically stained using antisera to SMC/Muc4 and ErbBs to determine their relative locations in the gland. Colocalization of SMC/Muc4 and ErbB2 was confirmed by confocal immunofluorescence. Sequential immunoprecipitation and immunoblot were performed to analyze complexes of the SMC/Muc4 and ErbB2 in the lacrimal tissue. Northern blot analyses of rat lacrimal glands, with a probe for SMC/Muc4, demonstrated the presence of a approximately 9-kb transcript, consistent with observations in other tissues. Similarly, immunoblot analyses with antibodies against both the transmembrane (ASGP-2) and mucin (ASGP-1) subunits showed the presence of the two SMC/Muc4 subunits in lysates from rat lacrimal gland. Significantly, two different forms of ASGP-2 were observed, a high-molecular-weight ( approximately 200-kDa) form and the more common 120- to 140-kDa form. Sequential immunoprecipitation and immunoblot analyses to differentiate membrane and soluble forms of SMC/Muc4 indicated that the high-molecular-weight form of ASGP-2 was predominantly associated with membranes, whereas the 120- to 140-kDa form was both membrane-associated and soluble. The lacrimal gland consists of acini connected by intercalated and interlobular ducts. Both acini and some intercalated ducts were stained by anti-ASGP-2 monoclonal antisera. Two patterns of acinar staining were observed: membrane staining

  16. A Case of Recurrent Schneiderian Papilloma of the Lacrimal Sac Invading the Nasal Cavity

    PubMed Central

    Jang, Ji Hye; Choe, Mi Sun

    2009-01-01

    A 44-year-old man presented with a history of chronic epiphora, discharge from the right eye, and a palpable mass in the medial canthal area. Irrigation of the lacrimal system revealed bloody discharge. Orbital magnetic resonance imaging (MRI) showed a well-defined heterogeneous enhanced mass filling the lacrimal sac and upper nasolacrimal duct (NLD). A wide excision and surgical biopsy were performed. Histopathology showed the tumor to be an exophytic Schneiderian papilloma with moderate to severe dysplasia. Three months later, the mass was found to be invading the nasal cavity through the NLD. Endoscopic histopathological evaluation confirmed that it was identical to the originally identified papilloma. PMID:19568358

  17. Microbiology and Biofilm Trends of Silicone Lacrimal Implants: Comparing Infected Versus Routinely Removed Stents.

    PubMed

    Samimi, David B; Ediriwickrema, Lilangi S; Bielory, Brett P; Miller, Darlene; Lee, Wendy; Johnson, Thomas E

    To investigate the pathogens and biofilms responsible for clinically significant infection of silicone stents implanted within the lacrimal system. Retrospective review of culture results and patient demographics for all silicone lacrimal stents removed early for clinically significant infection and sent to the Bascom Palmer Microbiology Laboratory through the end of year 2010. As a control, routinely removed, clinically noninfected stents from the same institution were prospectively sent for culture over a 6-month period. Four clinically infected and 6 clinically noninfected stents showing mucus within the lumen at removal were sent for scanning electron microscopy. Images were randomized and graded by a microbiologist for the presence of organisms, matrix deposits, organisms within matrix, and overall impression of significant biofilm formation. Nineteen stents were included in the study; 100% of clinically infected (n = 10) and noninfected (n = 9) stents were culture positive. Culture positivity for nontuberculous mycobacterium was found in 90% of infected stents and none of the noninfected stents (p < 0.001). Of infected stents, 50% grew Gram-positive organisms compared with 89% of noninfected stents (p = 0.07). Fifty percent of infected versus 67% of noninfected stents were culture positive for Gram-negative organisms (p = 0.46). Electron microscopy of stents revealed organisms consistent with culture results (size, shape) in planktonic and biofilm form. Masked observer image grading revealed a statistically significant higher amount of organism and biofilm on infected versus noninfected specimen. Nontuberculous mycobacteria comprise the primary pathogens responsible for clinically significant infection of silicone stents in the lacrimal system in South Florida. Robust biofilm production by this organism likely plays a role in pathogenesis. Further research into biofilm-related lacrimal implant infection may aid in the development of useful prevention and

  18. Transitional neoplasms of the naso-lacrimal system: A review of the histopathology and histogenesis☆

    PubMed Central

    Heathcote, J. Godfrey

    2012-01-01

    Transitional papilloma (inverted papilloma, Schneiderian papilloma) is a relatively common, benign epithelial neoplasm of the sinonasal tract that also occurs in the lacrimal drainage system. The name transitional papilloma is recommended because it reflects the key histological features required for pathological diagnosis, as well as the histogenesis of the tumour. The histogenesis of the tumour is reviewed, together with its natural history, which is characterized by bone remodelling and destruction, a tendency to recur and to undergo malignant transformation. Biomarkers associated with these features have been identified in the sinonasal tumours and may also be of relevance to the lacrimal sac tumours, although the necessary studies have not yet been undertaken. PMID:23960982

  19. Central Connections of the Lacrimal Functional Unit.

    PubMed

    Willshire, Catherine; Buckley, Roger J; Bron, Anthony J

    2017-08-01

    To study the contribution of each eye to the reflex tear response, after unilateral and bilateral topical anesthesia. A closed-eye, modified Schirmer test was performed bilaterally in 8 normal subjects, in a controlled environment chamber set to 23°C, 45% relative humidity, and 0.08 m/s airflow. Eye drops were instilled into each eye 10 minutes before the Schirmer test. Experiments were as follows: 1) bilateral saline (control), 2) unilateral anesthesia (ipsilateral anesthetic; contralateral saline), and 3) bilateral anesthesia. There was no difference in between-eye wetting lengths in the saline control eyes (P = 0.394) or the bilaterally anesthetized eyes (P = 0.171). The wetting length was reduced in both eyes after bilateral anesthesia compared with saline controls (P = 0.001; P ≤ 0.0005). After unilateral anesthesia, the wetting length was reduced in the anesthetized eye compared with its saline control by 51.4% (P ≤ 0.0005) and compared with its fellow, unanesthetized eye (P = 0.005). The fellow eye value was also reduced compared with its saline control (P = 0.06). The wetting length was reduced by topical anesthesia, when instilled bilaterally and ipsilaterally. The latter response implies an ipsilateral, reflex sensory drive to lacrimal secretion. In the unanesthetized fellow eye, the reduction compared with its saline control was not quite significant. This implies a relative lack of central, sensory, reflex cross-innervation, although the possibility cannot entirely be ruled out. These results are relevant to the possibility of reflex lacrimal compensation from a normal fellow eye, in cases of unilateral corneal anesthesia.

  20. MUC19 expression in human ocular surface and lacrimal gland and its alteration in Sjögren syndrome patients.

    PubMed

    Yu, D F; Chen, Y; Han, J M; Zhang, H; Chen, X P; Zou, W J; Liang, L Y; Xu, C C; Liu, Z G

    2008-02-01

    This study investigated the expression of MUC19, a newly discovered gel-forming mucin gene, in normal human lacrimal functional unit components and its alteration in Sjögren syndrome patients. Real-time PCR and immunohistochemistry were performed to determine the expression of MUC19 and MUC5AC in human cornea, conjunctiva, and lacrimal gland tissues. Conjunctival impression cytology specimens were collected from normal control subjects and Sjögren syndrome patients for Real-time PCR, PAS staining, and immunohistochemistry assays. In addition, conjunctiva biopsy specimens from both groups were examined for the expression differences of MUC19 and MUC5AC at both mRNA and protein level. The MUC19 mRNA was found to be present in cornea, conjunctiva and lacrimal gland tissues. The immunohistochemical staining of mucins showed that MUC19 was expressed in epithelial cells from corneal, conjunctival, and lacrimal gland tissues. In contrast, MUC5AC mRNA was only present in conjunctiva and lacrimal gland tissues, but not in cornea. Immunostaining demonstrates the co-staining of MUC19 and MUC5AC in conjunctival goblet cells. Consistent with the significant decrease of mucous secretion, both MUC19 and MUC5AC were decreased in conjunctiva of Sjögren syndrome patients compared to normal subjects. Considering the contribution of gel-forming mucins to the homeostasis of the ocular surface, the decreased expression of MUC19 and MUC5AC in Sjögren syndrome patients suggested that these mucins may be involved in the disruption of the ocular surface homeostasis in this disease.

  1. Altered Morphology and Function of the Lacrimal Functional Unit in Protein Kinase Cα Knockout Mice

    PubMed Central

    Chen, Zhuo; Li, Zhijie; Basti, Surendra; Farley, William J.

    2010-01-01

    Purpose. Protein kinase C (PKC) α plays a major role in the parasympathetic neural stimulation of lacrimal gland (LG) secretion. It also has been reported to have antiapoptotic properties and to promote cell survival. Therefore, the hypothesis for the present study was that PKCα knockout (−/−) mice have impaired ocular surface–lacrimal gland signaling, rendering them susceptible to desiccating stress and impaired corneal epithelial wound healing. In this study, the lacrimal function unit (LFU) and the stressed wound-healing response were examined in PKCα−/− mice. Methods. In PKCα+/+ control mice and PKCα−/− mice, tear production, osmolarity, and clearance rate were evaluated before and after experimental desiccating stress. Histology and immunofluorescent staining of PKC and epidermal growth factor were performed in tissues of the LFU. Cornified envelope (CE) precursor protein expression and cell proliferation were evaluated. The time course of healing and degree of neutrophil infiltration was evaluated after corneal epithelial wounding. Results. Compared with the PKCα+/+ mice, the PKCα−/− mice were noted to have significantly increased lacrimal gland weight, with enlarged, carbohydrate-rich, PAS-positive acinar cells; increased corneal epithelia permeability, with reduced CE expression; and larger conjunctival epithelial goblet cells. The PKCα−/− mice showed more rapid corneal epithelial healing, with less neutrophil infiltration and fewer proliferating cells than did the PKCα+/+ mice. Conclusions. The PKCα−/− mice showed lower tear production, which appeared to be caused by impaired secretion by the LG and conjunctival goblet cells. Despite their altered tear dynamics, the PKCα−/− mice demonstrated more rapid corneal epithelial wound healing, perhaps due to decreased neutrophil infiltration. PMID:20505191

  2. GCDFP-15, AR, and Her-2 as biomarkers for primary ductal adenocarcinoma of the lacrimal gland: a Chinese case and literature review

    PubMed Central

    Zhu, Miao-Miao; Cui, Hong-Guang; Teng, Xiao-Dong

    2015-01-01

    Purpose Primary ductal adenocarcinoma (PDA) of the lacrimal gland is a rare malignant epithelial tumor, and its clinicopathological characteristics are still unclear. This study aimed to report a novel case of PDA of the lacrimal gland in the People’s Republic of China, as well as to determine its histopathological and immunohistochemical characteristics to support early diagnosis and direct further therapy. Patient and methods Clinical data (including ocular examination, computed tomography, magnetic resonance imaging, positron emission tomography, mammography, and serum tumor marker examination) and treatment of a 49-year-old woman with a left lacrimal gland mass, which was diagnosed as PDA of the lacrimal gland, were reported. Histopathological and immunohistochemical studies were performed. Eleven papers regarding this uncommon neoplasm were reviewed. Results Histopathologically, most of the tumor cells featured abundant granular eosinophilic cytoplasm, while few of them had a frothy appearance. The mass showed breast ductal carcinoma-like structural features, which most commonly demonstrated central necrosis, while less of these features showed cord-like infiltration. Immunohistochemically, the tumor cells were positive for GCDFP-15, CK 18 (++), AR (90%), Her-2 (+++), P53 (100%), and Ki-67 (with a proliferation index approximately 60%), while they were negative for ER, PR, P63, calponin, and CD 117. Conclusion This was the first Chinese case of PDA of the lacrimal gland that had been reported. We suggested that GCDFP-15, AR, and Her-2 should be tested as biomarkers for ductal adenocarcinoma of lacrimal gland to confirm diagnosis, guide therapy, and further predict prognosis. PMID:25999735

  3. A rare case of atypical pleomorphic adenoma arising from periocular ectopic lacrimal gland.

    PubMed

    Wajda, Brynn N; Mancini, Ronald; Evers, Bret; Nick Hogan, R

    2018-06-23

    To describe features of atypical pleomorphic adenoma, a rare clinical entity, particularly when found in ectopic periocular lacrimal gland tissue. Case report of biopsy-confirmed periocular atypical pleomorphic adenoma. A 35-year-old female presented with a unique orbital lesion found to be ectopic lacrimal gland demonstrating atypical pleomorphic adenoma on formal histopathologic review. Pleomorphic adenoma is pathologically characterized as an epithelial lesion intermixed with mesenchymal elements. It is further classified as atypical with the presence of features such as hypercellularity, regions of necrosis or hyalinization, cellular dysplasia, capsular violation, and malignant characteristics without frank local extension or distant metastases. Due to its rarity, the natural history and prognosis of atypical pleomorphic adenoma is unclear. Physicians need to recognize this entity, and complete surgical excision with strict follow-up regimens are likely warranted.

  4. Altered morphology and function of the lacrimal functional unit in protein kinase C{alpha} knockout mice.

    PubMed

    Chen, Zhuo; Li, Zhijie; Basti, Surendra; Farley, William J; Pflugfelder, Stephen C

    2010-11-01

    Protein kinase C (PKC) α plays a major role in the parasympathetic neural stimulation of lacrimal gland (LG) secretion. It also has been reported to have antiapoptotic properties and to promote cell survival. Therefore, the hypothesis for the present study was that PKCα knockout ((-/-)) mice have impaired ocular surface-lacrimal gland signaling, rendering them susceptible to desiccating stress and impaired corneal epithelial wound healing. In this study, the lacrimal function unit (LFU) and the stressed wound-healing response were examined in PKCα(-/-) mice. In PKCα(+/+) control mice and PKCα(-/-) mice, tear production, osmolarity, and clearance rate were evaluated before and after experimental desiccating stress. Histology and immunofluorescent staining of PKC and epidermal growth factor were performed in tissues of the LFU. Cornified envelope (CE) precursor protein expression and cell proliferation were evaluated. The time course of healing and degree of neutrophil infiltration was evaluated after corneal epithelial wounding. Compared with the PKCα(+/+) mice, the PKCα(-/-) mice were noted to have significantly increased lacrimal gland weight, with enlarged, carbohydrate-rich, PAS-positive acinar cells; increased corneal epithelia permeability, with reduced CE expression; and larger conjunctival epithelial goblet cells. The PKCα(-/-) mice showed more rapid corneal epithelial healing, with less neutrophil infiltration and fewer proliferating cells than did the PKCα(+/+) mice. The PKCα(-/-) mice showed lower tear production, which appeared to be caused by impaired secretion by the LG and conjunctival goblet cells. Despite their altered tear dynamics, the PKCα(-/-) mice demonstrated more rapid corneal epithelial wound healing, perhaps due to decreased neutrophil infiltration.

  5. Primary lacrimal canaliculitis - A clinical entity often misdiagnosed.

    PubMed

    Singh, Manpreet; Gautam, Natasha; Agarwal, Aniruddha; Kaur, Manpreet

    2018-03-01

    Primary lacrimal canaliculitis (PLC) is a unique disorder which often gets misdiagnosed by the general as well as speciality-trained ophthalmologists. Elderly patients with history of chronic or recurrent epiphora with discharge, often get mislead towards chronic dacryocystitis. The aim of our report is to discuss the misleading diseases in our PLC patients and to revisit this hidden disease. The patients of PLC who were previously misdiagnosed were studied. The clinical history, presenting clinical features, misdiagnosis, and final management of the patients is described. There were 5 misdiagnosed female patients. A history of chronic redness, watering, discharge, and medial canthal region edema lead to the misdiagnosis of chronic dacryocystitis in 3 (60%) and medial marginal chalazion in 2 (40%) cases. Slit-lamp examination revealed localized hyperemia (n = 5), classical pouting of lacrimal punctum (n = 3), and expressible purulent discharge (n = 3). Two patients without punctum pouting had an explicit yellowish hue/discoloration of the canalicular region. Our patients had a mean 4 visits before an accurate diagnosis. Three-snip punctoplasty with canalicular curettage was performed in three while two were managed conservatively. At last follow-up, all patients were symptom-free with punctum and canalicular scarring in three, who underwent surgery. PLC is a frequently misdiagnosed clinical entity which delays the initiation of appropriate treatment. A succinct magnified examination of punctum and canalicular region can provide sufficient clues pivotal for accurate diagnosis.

  6. The natural process of congenital nasolacrimal duct obstruction and effect of lacrimal sac massage.

    PubMed

    Karti, Omer; Karahan, Eyyup; Acan, Durgul; Kusbeci, Tuncay

    2016-12-01

    This study aimed to examine the rate of symptomatic improvement of congenital nasolacrimal duct obstruction (CNLDO) in infants treated with conservative management within the first year of age. Other purpose of the study is to emphasize the relationship between spontaneous resolution time and effective lacrimal sac massage. Thirty-one infants were diagnosed to have CNLDO by an ophthalmologist prior to 3 months of age. In this study, 36 eyes of 31 patients were included with CNLDO. The patients were divided into two groups. Group 1 (28 eyes of 24 patients) was consisted of the patients who were applied effective lacrimal sac massage regularly during the follow-up period, and patients whose parents did not apply a regular lacrimal passage regularly were accepted as group 2 (8 eyes of 7 patients). Thirty-three eyes of 31 patients (18 rights and 15 left) successfully resolved with only conservative management (91.6 %). In these thirty-three eyes, one eye (3 %) resolved between 0 and 3 months, fourteen eyes (42.5 %) resolved between 4 and 6 months, eleven eyes (33.3 %) resolved between 7 and 9 months, and seven eyes (21.2 %) resolved between 10 and 12 months. CNLDO was resolved in 27 (96.2 %) of 28 eyes in group 1, and in group 2, six eyes (77.7 %) had resolvement. This difference was statistically significant (p = 0.001). The mean age of resolution was 6.8 ± 1.88 months in group 1, 10.3 ± 1.5 months in group 2 (p < 0.001). In light of our study, we believe that conservative management of CNLDO is highly successful. Our study provided a possible objective explanation for the efficacy of lacrimal sac massage. Emphasizing the importance of the massage to parents and describing in detail can reduce the risk of unnecessary surgical interventions.

  7. Common T cell receptor clonotype in lacrimal glands and labial salivary glands from patients with Sjögren's syndrome.

    PubMed Central

    Matsumoto, I; Tsubota, K; Satake, Y; Kita, Y; Matsumura, R; Murata, H; Namekawa, T; Nishioka, K; Iwamoto, I; Saitoh, Y; Sumida, T

    1996-01-01

    Sjogren's syndrome (SS) is an autoimmune disease characterized by lymphocytic infiltration into lacrimal and salivary glands leading to symptomatic dry eyes and mouth. Immunohistological studies have clarified that the majority of infiltrating lymphocytes around the lacrimal glands and labial salivary glands are CD4 positive alphabeta T cells. To analyze the pathogenesis of T cells infiltrating into lacrimal and labial salivary glands, we examined T cell clonotype of these cells in both glands from four SS patients using PCR-single-strand conformation polymorphism (SSCP) and a sequencing method. SSCP analysis showed that some infiltrating T cells in both glands expand clonally, suggesting that the cells proliferate by antigen-driven stimulation. Intriguingly, six to sixteen identical T cell receptor (TCR) Vbeta genes were commonly found in lacrimal glands and labial salivary glands from individual patients. This indicates that some T cells infiltrating into both glands recognize the shared epitopes on autoantigens. Moreover, highly conserved amino acid sequence motifs were found in the TCR CDR3 region bearing the same TCR Vbeta family gene from four SS patients, supporting the notion that the shared epitopes on antigens are limited. In conclusion, these findings suggest that some autoreactive T cells infiltrating into the lips and eyes recognized restricted epitopes of a common autoantigen in patients with SS. PMID:8621782

  8. Lymphotoxin-beta receptor blockade reduces CXCL13 in lacrimal glands and improves corneal integrity in the NOD model of Sjögren's syndrome

    PubMed Central

    2011-01-01

    Introduction In Sjögren's syndrome, keratoconjunctivitis sicca (dry eye) is associated with infiltration of lacrimal glands by leukocytes and consequent losses of tear-fluid production and the integrity of the ocular surface. We investigated the effect of blockade of the lymphotoxin-beta receptor (LTBR) pathway on lacrimal-gland pathology in the NOD mouse model of Sjögren's syndrome. Methods Male NOD mice were treated for up to ten weeks with an antagonist, LTBR-Ig, or control mouse antibody MOPC-21. Extra-orbital lacrimal glands were analyzed by immunohistochemistry for high endothelial venules (HEV), by Affymetrix gene-array analysis and real-time PCR for differential gene expression, and by ELISA for CXCL13 protein. Leukocytes from lacrimal glands were analyzed by flow-cytometry. Tear-fluid secretion-rates were measured and the integrity of the ocular surface was scored using slit-lamp microscopy and fluorescein isothiocyanate (FITC) staining. The chemokine CXCL13 was measured by ELISA in sera from Sjögren's syndrome patients (n = 27) and healthy controls (n = 30). Statistical analysis was by the two-tailed, unpaired T-test, or the Mann-Whitney-test for ocular integrity scores. Results LTBR blockade for eight weeks reduced B-cell accumulation (approximately 5-fold), eliminated HEV in lacrimal glands, and reduced the entry rate of lymphocytes into lacrimal glands. Affymetrix-chip analysis revealed numerous changes in mRNA expression due to LTBR blockade, including reduction of homeostatic chemokine expression. The reduction of CXCL13, CCL21, CCL19 mRNA and the HEV-associated gene GLYCAM-1 was confirmed by PCR analysis. CXCL13 protein increased with disease progression in lacrimal-gland homogenates, but after LTBR blockade for 8 weeks, CXCL13 was reduced approximately 6-fold to 8.4 pg/mg (+/- 2.7) from 51 pg/mg (+/-5.3) in lacrimal glands of 16 week old control mice. Mice given LTBR blockade exhibited an approximately two-fold greater tear-fluid secretion than

  9. Rapamycin Eye Drops Suppress Lacrimal Gland Inflammation In a Murine Model of Sjögren's Syndrome

    PubMed Central

    Shah, Mihir; Edman, Maria C.; Reddy Janga, Srikanth; Yarber, Frances; Meng, Zhen; Klinngam, Wannita; Bushman, Jonathan; Ma, Tao; Liu, Siyu; Louie, Stan; Mehta, Arjun; Ding, Chuanqing; MacKay, J. Andrew; Hamm-Alvarez, Sarah F.

    2017-01-01

    Purpose To evaluate the efficacy of topical rapamycin in treating autoimmune dacryoadenitis in a mouse model of Sjögren's syndrome. Methods We developed rapamycin in a poly(ethylene glycol)-distearoyl phosphatidylethanolamine (PEG-DSPE) micelle formulation to maintain solubility. Rapamycin or PEG-DSPE eye drops (vehicle) were administered in a well-established Sjögren's syndrome disease model, the male nonobese diabetic (NOD) mice, twice daily for 12 weeks starting at 8 weeks of age. Mouse tear fluid was collected and tear Cathepsin S, a putative tear biomarker for Sjögren's syndrome, was measured. Lacrimal glands were retrieved for histological evaluation, and quantitative real-time PCR of genes associated with Sjögren's syndrome pathogenesis. Tear secretion was measured using phenol red threads, and corneal fluorescein staining was used to assess corneal integrity. Results Lymphocytic infiltration of lacrimal glands from rapamycin-treated mice was significantly (P = 0.0001) reduced by 3.8-fold relative to vehicle-treated mice after 12 weeks of treatment. Rapamycin, but not vehicle, treatment increased tear secretion and decreased corneal fluorescein staining after 12 weeks. In rapamycin-treated mice, Cathepsin S activity was significantly reduced by 3.75-fold in tears (P < 0.0001) and 1.68-fold in lacrimal gland lysates (P = 0.003) relative to vehicle-treated mice. Rapamycin significantly altered the expression of several genes linked to Sjögren's syndrome pathogenesis, including major histocompatibility complex II, TNF-α, IFN-γ, and IL-12a, as well as Akt3, an effector of autophagy. Conclusions Our findings suggest that topical rapamycin reduces autoimmune-mediated lacrimal gland inflammation while improving ocular surface integrity and tear secretion, and thus has potential for treating Sjögren's syndrome–associated dry eye. PMID:28122086

  10. Regulating temporospatial dynamics of morphogen for structure formation of the lacrimal gland by chitosan biomaterials.

    PubMed

    Hsiao, Ya-Chuan; Yang, Tsung-Lin

    2017-01-01

    The lacrimal gland is an important organ responsible for regulating tear synthesis and secretion. The major work of lacrimal gland (LG) is to lubricate the ocular surface and maintain the health of eyes. Functional deterioration of the lacrimal gland happens because of aging, diseases, or therapeutic complications, but without effective treatments till now. The LG originates from the epithelium of ocular surface and develops by branching morphogenesis. To regenerate functional LGs, it is required to explore the way of recapitulating and facilitating the organ to establish the intricate and ramified structure. In this study, we proposed an approach using chitosan biomaterials to create a biomimetic environment beneficial to the branching structure formation of developing LG. The morphogenetic effect of chitosan was specific and optimized to promote LG branching. With chitosan, increase in temporal expression and local concentration of endogenous HGF-related molecules creates an environment around the emerging tip of LG epithelia. By efficiently enhancing downstream signaling of HGF pathways, the cellular activities and behaviors were activated to contribute to LG branching morphogenesis. The morphogenetic effect of chitosan was abolished by either ligand or receptor deprivation, or inhibition of downstream signaling transduction. Our results elucidated the underlying mechanism accounting for chitosan morphogenetic effects on LG, and also proposed promising approaches with chitosan to assist tissue structure formation of the LG. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Role of chemotherapy and molecularly targeted agents in the treatment of adenoid cystic carcinoma of the lacrimal gland.

    PubMed

    Le Tourneau, Christophe; Razak, Albiruni R A; Levy, Christine; Calugaru, Valentin; Galatoire, Olivier; Dendale, Rémi; Desjardins, Laurence; Gan, Hui K

    2011-11-01

    Adenoid cystic carcinoma (ACC) is the most common malignant epithelial cancer of the lacrimal gland. Despite a slow rate of growth, ACCs are ultimately associated with poor clinical outcome. Given the rarity of this disease, most recommendations regarding therapy are guided by expert opinion and retrospective data rather than level 1 evidence. Surgery and postoperative radiation therapy are commonly used as initial local treatment. In patients at high risk of recurrence, concomitant platinum-based chemotherapy may be added to postoperative radiotherapy in an attempt to enhance radio-sensitivity. While encouraging responses have been reported with intra-arterial neoadjuvant chemotherapy, this strategy is associated with substantial toxicity and should be considered investigational. For patients with metastatic disease not amenable to surgery or radiotherapy, chemotherapy may have a role based on its modest efficacy in non-lacrimal ACC. Similarly, molecular targeted agents may have a role, although the agents tested to date in non-lacrimal ACC have been disappointing. A better understanding of the biology of ACC will be crucial to the future success of developing targeted agents for this disease.

  12. Effect of sensory denervation on the structure and physiologic responsiveness of rabbit lacrimal gland.

    PubMed

    Meneray, M A; Bennett, D J; Nguyen, D H; Beuerman, R W

    1998-01-01

    This work was conducted to determine the effects of unilateral trigeminal ganglion ablation on lacrimal gland structure and secretory activity. Adult male New Zealand rabbits underwent unilateral thermocoagulation of the ophthalmic division of the trigeminal ganglion. Sensory denervation was affirmed by anatomic inspection of the lesion and transmission electron microscopy (TEM) of the lacrimal gland innervation. Eight to 10 days after the procedure, the intraorbital lacrimal glands were removed from both sides. To compare the physiologic competence of the intact and denervated glands, freshly isolated gland fragments from the paired intact and denervated glands were stimulated with carbachol (100 microM), isoproterenol (10 microM), phorbol-12,13-dibutyrate (PDBu, 10 microM), forskolin (40 microM), or vehicle. Total secreted protein was measured at 30 or 60 min after the establishment of baseline values. Intact and denervated glands also were examined by light and TEM, and the morphologic appearance of the acinar structures as well as the appearance of nerves innervating the gland after denervation were assessed. Similar experiments were conducted with animals that underwent unilateral superior cervical ganglionectomy. Tissues from sensory denervated glands released significantly more protein than did tissues from innervated glands in response to in vitro stimulation by carbachol or isoproterenol but not in response to PDBu or forskolin. Microscopy showed that the acinar cells that had undergone sensory denervation showed a massive accumulation of secretory granules. The secretory granules filled the entire cytoplasmic space and displaced the ellipsoidal nuclei to the extreme periphery. Examination of segments of nerves revealed numerous unmyelinated axons, a few small-diameter myelinated axons, and a large amount of nerve degeneration after sensory denervation. In contrast to the effects of sensory denervation, sympathetic denervation did not alter either the

  13. Gene Expression Profiling and Heterogeneity of Nonspecific Orbital Inflammation Affecting the Lacrimal Gland.

    PubMed

    Rosenbaum, James T; Choi, Dongseok; Harrington, Christina A; Wilson, David J; Grossniklaus, Hans E; Sibley, Cailin H; Salek, Sherveen S; Ng, John D; Dailey, Roger A; Steele, Eric A; Hayek, Brent; Craven, Caroline M; Edward, Deepak P; Maktabi, Azza M Y; Al Hussain, Hailah; White, Valerie A; Dolman, Peter J; Czyz, Craig N; Foster, Jill A; Harris, Gerald J; Bee, Youn-Shen; Tse, David T; Alabiad, Chrisfouad R; Dubovy, Sander R; Kazim, Michael; Selva, Dinesh; Yeatts, R Patrick; Korn, Bobby S; Kikkawa, Don O; Silkiss, Rona Z; Sivak-Callcott, Jennifer A; Stauffer, Patrick; Planck, Stephen R

    2017-11-01

    Although a variety of well-characterized diseases, such as sarcoidosis and granulomatosis with polyangiitis, affect the lacrimal gland, many patients with dacryoadenitis are diagnosed as having nonspecific orbital inflammation (NSOI) on the basis of histology and systemic disease evaluation. The ability to further classify the disease in these patients should facilitate selection of effective therapies. To test the a priori hypothesis that gene expression profiles would complement clinical and histopathologic evaluations in identifying well-characterized diseases and in subdividing NSOI into clinically relevant groups. In this cohort study, gene expression levels in biopsy specimens of inflamed and control lacrimal glands were measured with microarrays. Stained sections of the same biopsy specimens were used for evaluation of histopathology. Tissue samples of patients were obtained from oculoplastic surgeons at 7 international centers representing 4 countries (United States, Saudi Arabia, Canada, and Taiwan). Gene expression analysis was done at Oregon Health & Science University. Participants were 48 patients, including 3 with granulomatosis with polyangiitis, 28 with NSOI, 7 with sarcoidosis, 4 with thyroid eye disease, and 6 healthy controls. The study dates were March 2012 to April 2017. The primary outcome was subdivision of biopsy specimens based on gene expression of a published list of approximately 40 differentially expressed transcripts in blood, lacrimal gland, and orbital adipose tissue from patients with sarcoidosis. Stained sections were evaluated for inflammation (none, mild, moderate, or marked), granulomas, nodules, or fibrosis by 2 independent ocular pathologists masked to the clinical diagnosis. Among 48 patients (mean [SD] age, 41.6 [19.0] years; 32 [67%] female), the mclust algorithm segregated the biopsy specimens into 4 subsets, with the differences illustrated by a heat map and multidimensional scaling plots. Most of the sarcoidosis biopsy

  14. Identification of P2X3 and P2X7 Purinergic Receptors Activated by ATP in Rat Lacrimal Gland

    PubMed Central

    Vrouvlianis, Joanna; Scott, Rachel; Dartt, Darlene A.

    2011-01-01

    Purpose. To identify the type of purinergic receptors activated by adenosine triphosphate (ATP) in rat lacrimal gland and to determine their role in protein secretion. Methods. Purinergic receptors were identified by RT-PCR, Western blot analysis, and immunofluorescence techniques. Acini from rat lacrimal gland were isolated by collagenase digestion. Acini were incubated with the fluorescence indicator fura-2 tetra-acetoxylmethyl ester, and intracellular [Ca2+] ([Ca2+]i) was determined. Protein secretion was measured by fluorescence assay. Results. The authors previously showed that P2X7 receptors were functional in the lacrimal gland. In this study, they show that P2X1–4, and P2X6receptors were identified in the lacrimal gland by RT-PCR, Western blot, and immunofluorescence analyses. P2X5 receptors were not detected. ATP increased [Ca2+]i and protein secretion in a concentration-dependent manner. Removal of extracellular Ca2+ significantly reduced the ATP-stimulated increase in [Ca2+]i. Repeated applications of ATP caused desensitization of the [Ca2+]i response. Incubation with the P2X1 receptor inhibitor NF023 did not alter ATP-stimulated [Ca2+]i. Incubation with zinc, which potentiates P2X2 and P2X4 receptor responses, or lowering the pH to 6.8, which potentiates P2X2 receptor responses, did not alter the ATP-stimulated [Ca2+]i. P2X3 receptor inhibitors A-317491 and TNP-ATP significantly decreased ATP-stimulated [Ca2+]i and protein secretion, whereas the P2X3 receptor agonist α,β methylene ATP significantly increased them. The P2X7 receptor inhibitor A438079 had no effect on ATP-stimulated [Ca2+]i at 10−6 M but did have an effect at 10−4 M. Conclusions. Purinergic receptors P2X1–4 and P2X6 are present in the lacrimal gland. ATP uses P2X3 and P2X7 receptors to stimulate an increase in [Ca2+]i and protein secretion. PMID:21421865

  15. Endoscopic-modified medial maxillectomy and its limitation for a solitary fibrous tumor of the lacrimal sac and nasolacrimal duct.

    PubMed

    Moriyama, Munehito; Kodama, Satoru; Hirano, Takashi; Suzuki, Masashi

    2017-06-01

    Solitary fibrous tumor (SFT) is an uncommon neoplasm that usually arises from the pleura. Recently, SFTs have been reported in the head and neck region located in subsites such as the orbit. SFTs of the lacrimal sac are extremely rare, with only six cases reported in the English literature. We describe a SFT arising from the right lacrimal sac and extending along the nasolacrimal duct into the nasal cavity. Although, the tumor could not be removed by endoscopic-modified medial maxillectomy (EMMM) alone, combined approach with EMMM and a small external incision achieved the complete removal of the tumor. The patient has remained disease-free 24 months after surgery. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. Effect of radioactive iodine therapy on lacrimal gland functions in patients with hyperthyroidism.

    PubMed

    Aydogan, Fusun; Ayhan Tuzcu, Esra; Aydogan, Akin; Akkucuk, Seckin; Coskun, Mesut; Ustun, Ihsan; Gökçe, Cumali

    2014-04-01

    Radioactive iodine (RAI) therapy is preferred in the treatment of hyperthyroidism because of its effectiveness, noninvasiveness, and low costs. I has been detected in extrathyroidal tissues, such as in gastric mucosa, salivary glands, and lacrimal glands. To the best of our knowledge, there is no publication concerning the effects of RAI therapy for hyperthyroidism on tear production. In the present study, we evaluated whether or not the lacrimal glands are affected after RAI therapy when compared with pretreatment period. The Schirmer and tear break-up time (TBUT) tests were used to assess 32 eyes of 16 patients with conditions that were diagnosed as hyperthyroidism before and at 3 and 6 months after RAI treatment. In addition, pretreatment values of patients were compared with that of controls. It was evaluated whether or not a correlation exists between the results and the dose or iodine uptake values. There was no significant difference between pretreatment values of Schirmer and TBUT tests obtained in the patient group and those of the control group (P > 0.05). In the patient group, there was a significant difference between the posttreatment and pretreatment values (P < 0.05). There was a positive correlation between uptake values obtained at 24 hours and the values obtained by TBUT and Schirmer tests on both eyes at 3 and 6 months. At 6 months, the uptake value at 24 hours was 28.83 ± 60 for both eyes in patients with TBUT test values less than 10, whereas it was 39.25 ± 7.88 for the right eye and 39.00 ± 6.85 for the left eyes in patients with TBUT test values greater than 10. The difference was statistically significant (P < 0.05). In our study, we concluded that the decrease in mucin and aqueous production occurs due to affected lacrimal glands by RAI therapy; however, this effect is not dose dependent.

  17. Development of lacrimal gland spheroids for lacrimal gland tissue regeneration.

    PubMed

    Massie, Isobel; Spaniol, Kristina; Barbian, Andreas; Geerling, Gerd; Metzger, Marco; Schrader, Stefan

    2018-04-01

    Severe dry eye syndrome resulting from lacrimal gland (LG) dysfunction can cause blindness, yet treatments remain palliative. In vitro reconstruction of LG tissue could provide a curative treatment. We aimed to combine epithelial cells with endothelial cells and mesenchymal stem cells (MSCs) to form a 3D functional unit. Epithelial cells and MSCs were isolated from porcine LG; endothelial cells were isolated from human foreskin. MSCs were characterised (flow cytometry and differentiation potential assays). All 3 cell types were combined on Matrigel and spheroid formation observed. Spheroids were characterised [immunohistochemistry (IHC) and transmission electron microscopy] and function assessed (β-hexosaminidase assay). Spheroids were transferred to decellularised jejunum (SIS-Muc) in dynamic cultures for 1 week before further characterisation. MSCs did not express CD31 but expressed CD44 and CD105 and differentiated towards osteogenic and adipogenic lineages. Spheroids formed on Matrigel within 18 hr, contracting to ~10% of the well area (p < .005). IHC revealed presence of all 3 cells within spheroids. Transmission electron microscopy revealed cell-cell contacts and polarisation at the apical surface. In static cultures, function was increased in spheroids cf. monolayer controls (p < .05) but over 72 hr, spheroid function (p < .05), viability (p < .05), and proliferation decreased, whilst apoptosis increased. On SIS-Muc under dynamic culture, however, spheroids continued to proliferate to repopulate SIS-Muc. IHC revealed LG epithelial cells coexpressing pan-cytokeratin and lysozyme, as well as endothelial cells and MSCs and cells remained capable of responding to carbachol (p < .05). These spheroids could form the basis of a regenerative medicine treatment approach for dry eye syndrome. In vivo studies are required to evaluate this further. Copyright © 2017 John Wiley & Sons, Ltd.

  18. TH17 cells mediate inflammation in a novel model of spontaneous experimental autoimmune lacrimal keratoconjunctivitis with neural damage.

    PubMed

    Seo, Kyoung Yul; Kitamura, Kazuya; Han, Soo Jung; Kelsall, Brian

    2017-09-27

    Dry eye disease (DED) affects one third of the population worldwide. In prior studies, experimental autoimmune lacrimal keratoconjunctivitis (EALK) induced by desiccating stress in mice has been used as a model of DED. This model is complicated by a requirement for exogenous epithelial cell injury and administration of anticholinergic agents with broad immunologic effects. We sought to develop a novel mouse model of EALK and to demonstrate the responsible pathogenic mechanisms. CD4 + CD45RB high naive T cells with and without CD4 + CD45RB low regulatory T cells were adoptively transferred to C57BL/10 recombination-activating gene 2 (Rag2) -/- mice. The eyes, draining lymph nodes, lacrimal glands, and surrounding tissues of mice with and without spontaneous keratoconjunctivitis were evaluated for histopathologic changes, cellular infiltration, and cytokine production in tissues and isolated cells. Furthermore, the integrity of the corneal nerves was evaluated using whole-tissue immunofluorescence imaging. Gene-deficient naive T cells or RAG2-deficient hosts were evaluated to assess the roles of IFN-γ, IL-17A, and IL-23 in disease pathogenesis. Finally, cytokine levels were determined in the tears of patients with DED. EALK developed spontaneously in C57BL/10 Rag2 -/- mice after adoptive transfer of CD4 + CD45RB high naive T cells and was characterized by infiltration of CD4 + T cells, macrophages, and neutrophils. In addition to lacrimal keratoconjunctivitis, mice had damage to the corneal nerve, which connects components of the lacrimal functional unit. Pathogenic T-cell differentiation was dependent on IL-23p40 and controlled by cotransferred CD4 + CD45RB low regulatory T cells. T H 17 rather than T H 1 CD4 + cells were primarily responsible for EALK, even though levels of both IL-17 and IFN-γ were increased in inflammatory tissues, likely because of their ability to drive expression of CXC chemokines within the cornea and the subsequent influx of myeloid cells

  19. Topical Application of Apricot Kernel Extract Improves Dry Eye Symptoms in a Unilateral Exorbital Lacrimal Gland Excision Mouse

    PubMed Central

    Kim, Chan-Sik; Jo, Kyuhyung; Lee, Ik-Soo; Kim, Junghyun

    2016-01-01

    The purpose of this study was to investigate the therapeutic effects of topical application of apricot kernel extract (AKE) in a unilateral exorbital lacrimal gland excision mouse model of experimental dry eye. Dry eye was induced by surgical removal of the lacrimal gland. Eye drops containing 0.5 or 1 mg/mL AKE were administered twice a day from day 3 to day 7 after surgery. Tear fluid volume and corneal irregularity scores were determined. In addition, we examined the immunohistochemical expression level of Muc4. The topical administration of AKE dose-dependently improved all clinical dry eye symptoms by promoting the secretion of tear fluid and mucin. Thus, the results of this study indicate that AKE may be an efficacious topical agent for treating dry eye disease. PMID:27886047

  20. Topical Application of Apricot Kernel Extract Improves Dry Eye Symptoms in a Unilateral Exorbital Lacrimal Gland Excision Mouse.

    PubMed

    Kim, Chan-Sik; Jo, Kyuhyung; Lee, Ik-Soo; Kim, Junghyun

    2016-11-23

    The purpose of this study was to investigate the therapeutic effects of topical application of apricot kernel extract (AKE) in a unilateral exorbital lacrimal gland excision mouse model of experimental dry eye. Dry eye was induced by surgical removal of the lacrimal gland. Eye drops containing 0.5 or 1 mg/mL AKE were administered twice a day from day 3 to day 7 after surgery. Tear fluid volume and corneal irregularity scores were determined. In addition, we examined the immunohistochemical expression level of Muc4. The topical administration of AKE dose-dependently improved all clinical dry eye symptoms by promoting the secretion of tear fluid and mucin. Thus, the results of this study indicate that AKE may be an efficacious topical agent for treating dry eye disease.

  1. Cytochrome P450 3A expression and activity in the rabbit lacrimal gland: glucocorticoid modulation and the impact on androgen metabolism.

    PubMed

    Attar, Mayssa; Ling, Kah-Hiing John; Tang-Liu, Diane D-S; Neamati, Nouri; Lee, Vincent H L

    2005-12-01

    Cytochrome P450 3A (CYP3A) is an enzyme of paramount importance to drug metabolism. The expression and activity of CYP3A, an enzyme responsible for active androgen clearance, was investigated in the rabbit lacrimal gland. Analysis of CYP3A expression and activity was performed on lacrimal gland tissues obtained from naïve untreated and treated New Zealand White rabbits. For 5 days, treated rabbits received daily administration of vehicle or 0.1% or 1.0% dexamethasone, in the lower cul-de-sac of each eye. Changes in mRNA expression were monitored by real-time RT-PCR. Protein expression was confirmed by Western blot. Functional activity was measured by monitoring the metabolism of CYP3A probe substrates-namely, 7-benzyloxyquinoline (BQ) and [3H]testosterone. Cytochrome P450 heme protein was detected at a concentration of 44.6 picomoles/mg protein, along with its redox partner NADPH reductase and specifically CYP3A6 in the naïve rabbit lacrimal gland. Genes encoding CYP3A6, in addition to the pregnane-X-receptor (PXR) and P-glycoprotein (P-gp) were expressed in the untreated tissue. BQ dealkylation was measured in the naïve rabbit lacrimal gland at a rate of 14 +/- 7 picomoles/mg protein per minute. Changes in CYP3A6, P-gp, and androgen receptor mRNA expression levels were detected after dexamethasone treatment. In addition, dexamethasone treatment resulted in significant increases in BQ dealkylation and CYP3A6-mediated [3H]testosterone metabolism. Concomitant increases in CYP3A6-mediated hydroxylated testosterone metabolites were observed in the treated rabbits. Furthermore, ketoconazole, all-trans retinoic acid, and cyclosporine inhibited CYP3A6 mediated [3H]testosterone 6beta hydroxylation in a concentration-dependent manner, with IC50 ranging from 3.73 to 435 microM. The results demonstrate, for the first time, the expression and activity of CYP3A6 in the rabbit lacrimal gland. In addition, this pathway was shown to be subject to modulation by a commonly

  2. Adenoid cystic carcinomas of the salivary gland, lacrimal gland, and breast are morphologically and genetically similar but have distinct microRNA expression profiles.

    PubMed

    Andreasen, Simon; Tan, Qihua; Agander, Tina Klitmøller; Steiner, Petr; Bjørndal, Kristine; Høgdall, Estrid; Larsen, Stine Rosenkilde; Erentaite, Daiva; Olsen, Caroline Holkmann; Ulhøi, Benedicte Parm; von Holstein, Sarah Linéa; Wessel, Irene; Heegaard, Steffen; Homøe, Preben

    2018-02-21

    Adenoid cystic carcinoma is among the most frequent malignancies in the salivary and lacrimal glands and has a grave prognosis characterized by frequent local recurrences, distant metastases, and tumor-related mortality. Conversely, adenoid cystic carcinoma of the breast is a rare type of triple-negative (estrogen and progesterone receptor, HER2) and basal-like carcinoma, which in contrast to other triple-negative and basal-like breast carcinomas has a very favorable prognosis. Irrespective of site, adenoid cystic carcinoma is characterized by gene fusions involving MYB, MYBL1, and NFIB, and the reason for the different clinical outcomes is unknown. In order to identify the molecular mechanisms underlying the discrepancy in clinical outcome, we characterized the phenotypic profiles, pattern of gene rearrangements, and global microRNA expression profiles of 64 salivary gland, 9 lacrimal gland, and 11 breast adenoid cystic carcinomas. All breast and lacrimal gland adenoid cystic carcinomas had triple-negative and basal-like phenotypes, while salivary gland tumors were indeterminate in 13% of cases. Aberrations in MYB and/or NFIB were found in the majority of cases in all three locations, whereas MYBL1 involvement was restricted to tumors in the salivary gland. Global microRNA expression profiling separated salivary and lacrimal gland adenoid cystic carcinoma from their respective normal glands but could not distinguish normal breast adenoid cystic carcinoma from normal breast tissue. Hierarchical clustering separated adenoid cystic carcinomas of salivary gland origin from those of the breast and placed lacrimal gland carcinomas in between these. Functional annotation of the microRNAs differentially expressed between salivary gland and breast adenoid cystic carcinoma showed these as regulating genes involved in metabolism, signal transduction, and genes involved in other cancers. In conclusion, microRNA dysregulation is the first class of molecules separating adenoid

  3. Lacritin and Other New Proteins of the Lacrimal Functional Unit

    PubMed Central

    McKown, Robert L.; Wang, Ningning; Raab, Ronald W.; Karnati, Roy; Zhang, Yinghui; Williams, Patricia B.; Laurie, Gordon W.

    2009-01-01

    The lacrimal functional unit (LFU) is defined by the 2007 International Dry Eye WorkShop as ‘an integrated system comprising the lacrimal glands, ocular surface (cornea, conjunctiva and meibomian glands) and lids, and the sensory and motor nerves that connect them’. The LFU maintains a healthy ocular surface primarily through a properly functioning tear film that provides protection, lubrication, and an environment for corneal epithelial cell renewal. LFU cells express thousands of proteins. Over two hundred new LFU proteins have been discovered in the last decade. Lacritin is a new LFU-specific growth factor in human tears that flows through ducts to target corneal epithelial cells on the ocular surface. When applied topically in rabbits, lacritin appears to increase the volume of basal tear secretion. Lacritin is one of only a handful of tear proteins preliminarily reported to be downregulated in blepharitis and in two dry eye syndromes. Computational analysis predicts an ordered C-terminal domain that binds the corneal epithelial cell surface proteoglycan syndecan-1 (SDC1) and is required for lacritin’s low nanomolar mitogenic activity. The lacritin binding site on the N-terminus of SDC1 is exposed by heparanase. Heparanase is constitutively expressed by the corneal epithelium and appears to be a normal constituent of tears. Binding triggers rapid signaling to downstream NFAT and mTOR. A wealth of other new proteins, originally designated as hypothetical when first identified by genomic sequencing, are expressed by the human LFU including: ALS2CL, ARHGEF19, KIAA1109, PLXNA1, POLG, WIPI1 and ZMIZ2. Their demonstrated or implied roles in human genetic disease or basic cellular functions are fuel for new investigation. Addressing topical areas in ocular surface physiology with new LFU proteins may reveal interesting new biological mechanisms and help get to the heart of ocular surface dysfunction. PMID:18840430

  4. Lacritin and other new proteins of the lacrimal functional unit.

    PubMed

    McKown, Robert L; Wang, Ningning; Raab, Ronald W; Karnati, Roy; Zhang, Yinghui; Williams, Patricia B; Laurie, Gordon W

    2009-05-01

    The lacrimal functional unit (LFU) is defined by the 2007 International Dry Eye WorkShop as 'an integrated system comprising the lacrimal glands, ocular surface (cornea, conjunctiva and meibomian glands) and lids, and the sensory and motor nerves that connect them'. The LFU maintains a healthy ocular surface primarily through a properly functioning tear film that provides protection, lubrication, and an environment for corneal epithelial cell renewal. LFU cells express thousands of proteins. Over 200 new LFU proteins have been discovered in the last decade. Lacritin is a new LFU-specific growth factor in human tears that flows through ducts to target corneal epithelial cells on the ocular surface. When applied topically in rabbits, lacritin appears to increase the volume of basal tear secretion. Lacritin is one of only a handful of tear proteins preliminarily reported to be downregulated in blepharitis and in two dry eye syndromes. Computational analysis predicts an ordered C-terminal domain that binds the corneal epithelial cell surface proteoglycan syndecan-1 (SDC1) and is required for lacritin's low nanomolar mitogenic activity. The lacritin-binding site on the N-terminus of SDC1 is exposed by heparanase. Heparanase is constitutively expressed by the corneal epithelium and appears to be a normal constituent of tears. Binding triggers rapid signaling to downstream NFAT and mTOR. A wealth of other new proteins, originally designated as hypothetical when first identified by genomic sequencing, are expressed by the human LFU including: ALS2CL, ARHGEF19, KIAA1109, PLXNA1, POLG, WIPI1 and ZMIZ2. Their demonstrated or implied roles in human genetic disease or basic cellular functions are fuel for new investigation. Addressing topical areas in ocular surface physiology with new LFU proteins may reveal interesting new biological mechanisms and help get to the heart of ocular surface dysfunction.

  5. Efficacy of laser stimulation of the lacrimal gland and collagen punctual occlusion in the treatment of dry-eye syndrome

    NASA Astrophysics Data System (ADS)

    Switka-Wieclawska, Iwona; Kecik, Tadeusz; Ciszewska, Joanna

    1997-10-01

    In this study we would like to monitor the tear secretion during a 7 day period of temporary intracanalicular occlusion and laser stimulation of lacrimal gland in a small group of female suffering of dry eye syndrome.

  6. Cryopreservation and hypothermic storage of lacrimal gland: towards enabling delivery of regenerative medicine therapies for treatment of dry eye syndrome.

    PubMed

    Massie, I; Spaniol, K; Geerling, G; Schrader, S

    2017-12-01

    Severe dry eye syndrome (DES) can cause painful loss of vision and may result from lacrimal gland dysfunction. Current treatments are palliative, so a causative therapy is desirable. The ability to (cryo)preserve lacrimal gland tissue or epithelial cells would simplify this. Here, lacrimal gland tissue was cryopreserved in 10% dimethylsulphoxide in liquid nitrogen, or stored at 4 °C in culture medium for up to 7 days, and compared with fresh tissue using immunohistochemistry. Cultures were initiated from fresh and stored tissue, and cells characterised in P1 for proliferation (WST-1), colony-forming efficiency (CFE) and secretory capacity (immunocytochemistry and β-hexosaminidase activity assay). Tissue stored for > 3 days at 4 °C displayed grossly altered tissue architecture when compared with fresh tissue, decreased acinus density and increased caspase-3 activity. Cryopreserved tissue showed less obvious signs of damage without caspase-3 activation. Storage at 4 °C and cryopreservation delayed epithelial outgrowth compared with that from fresh tissue initially (p  <  0.05) but, by day 9, all explants showed comparable outgrowth (~90%), except tissue stored at 4 °C for 3 or 7 days (p  <  0.05 compared with fresh tissue). Epithelial cell yields per explant were similar from fresh and stored tissue, apart from tissue stored at 4 °C for 7 days (p  <  0.01). In P1, epithelial cells from fresh and stored tissue were largely equivalent in terms of: proliferation; CFE (~21%); Rab3D, HexA and lysozyme expression; mucin production; and β-hexosaminidase activity. These data demonstrate that cryo(preservation) of lacrimal gland tissue and cells is possible, which may enable use of autologous cells in regenerative medicine approaches to treating DES. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  7. Orbital adenocarcinoma of lacrimal gland origin in a dog.

    PubMed

    Wang, F I; Ting, C T; Liu, Y S

    2001-03-01

    A 13-year-old intact female mixed-breed dog was presented for a progressive enlargement of the right eye, which had been treated previously for conjunctivitis. A round, firm mass, approximately 4 cm in diameter, was protruding from the superotemporal aspect of the right orbit, displacing the eyeball anteriorly and ventromedially. The mass was encapsulated, distinct from the eyeball, and not associated with the eyelids. On cut surface, there was a pale multilobulated periphery, with a dark red, soft, and depressed core. Histologically, tumor cells formed cords and tubules, which were stained with mouse anti-human cytokeratin antibody AE1/AE3. Residual glands were serous, and the majority of tumor cells were negative for mucin. The supraorbital location, encapsulation, and residual serous glands suggest that this mass was a low-grade adenocarcinoma of the lacrimal gland.

  8. Comparison of telomere length and association with progenitor cell markers in lacrimal gland between Sjögren syndrome and non-Sjögren syndrome dry eye patients

    PubMed Central

    Kawashima, Motoko; Maida, Yoshiko; Kamoi, Mizuka; Ogawa, Yoko; Shimmura, Shigeto; Masutomi, Kenkichi; Tsubota, Kazuo

    2011-01-01

    Purpose Indicators of aging such as disruption of telomeric function due to shortening may be more frequent in dysfunctional lacrimal gland. The aims of this study were to 1) determine the viability of quantitative fluorescence in situ hybridization of telomeres (telo-FISH) for the assessment of telomere length in lacrimal gland in Sjögren and non- Sjögren syndrome patients; and 2) investigate the relationship between progenitor cell markers and telomere length in both groups. Methods Quantitative fluorescence in situ hybridization with a peptide nucleic acid probe complementary to the telomere repeat sequence was performed on frozen sections from human lacrimal gland tissues. The mean fluorescence intensity of telomere spots was automatically quantified by image analysis as relative telomere length in lacrimal gland epithelial cells. Immunostaining for p63, nucleostemin, ATP-binding cassette, sub-family G, member 2 (ABCG2), and nestin was also performed. Results Telomere intensity in the Sjögren syndrome group (6,785.0±455) was significantly lower than that in the non-Sjögren syndrome group (7,494.7±477; p=0.02). Among the samples from the non-Sjögren syndrome group, immunostaining revealed that p63 was expressed in 1–3 acinar cells in each acinar unit and continuously in the basal layer of duct cells. In contrast, in the Sjögren syndrome group, p63 and nucleostemin showed a lower level of expression. ABCG2 was expressed in acinar cells in both sjogren and non-Sjogren syndrome. Conclusions The results of this study indicate that 1) telo-FISH is a viable method of assessing telomere length in lacrimal gland, and 2) telomere length in Sjögren syndrome is shorter and associated with lower levels of expression of p63 and nucleostemin than in non-Sjögren syndrome. PMID:21655359

  9. [Structuro-functional units of the salivary and lacrimal glands].

    PubMed

    Kostilenko, Iu P; Mysliuk, I V; Deviatkin, E A

    1986-09-01

    By means of the multilayer graphic and plastic reconstruction methods using series of semithin sections, spatial tridimensional organization of the epithelial complexes and blood microcirculatory bed in the rat palatal salivary glands and the lacrimal gland of the human newborn have been studied. Since their ducts serve not only for discharging their secrete into the external medium, but also for accumulation (as collectors), the sublobular unit--adenomere should be referred to as a part of elementary level of organization of the epithelial complexes. The adenomere has in its composition a collecting centrally situating duct. However, while studying structure of the blood microcirculatory bed, it is found out that there is not any strict territorial correspondence between its functional units and structural units of the glandular epithelium. Nevertheless, giving a great importance to a tight syntopic connection of the collecting ducts of the adenomeres with the postcapillary venules (that belong to filtrating microvessels), these are sublobular units--adenomeres that are distinguished as structural-functional units in the glands.

  10. Acro-Dermato-Ungual-Lacrimal-Tooth Syndrome: An Uncommon Member of the Ectodermal Dysplasias.

    PubMed

    Whittington, Adam; Stein, Sarah; Kenner-Bell, Brandi

    2016-09-01

    Acro-dermato-ungual-lacrimal-tooth (ADULT) syndrome is a rare form of autosomal dominant ectodermal dysplasia due to mutations in the TP63 gene, a locus that has also been implicated in other syndromic forms of ectodermal dysplasia. It shares many phenotypic characteristics with other TP63 gene mutation syndromes, often making an accurate diagnosis difficult. Long-term management and follow-up of the various sequelae of ectodermal dysplasia require an accurate diagnosis. We report a familial case of ADULT syndrome in a daughter, mother, and son and provide a brief review of the clinical characteristics of this syndrome. © 2016 Wiley Periodicals, Inc.

  11. [Lacrimal gland-associated mucins. Age related production and their role in the pathophysiology of dry eye].

    PubMed

    Schäfer, G; Hoffmann, W; Berry, M; Paulsen, F

    2005-02-01

    The secretory cells of the human lacrimal gland show a PAS-positive reaction in cytochemical staining procedures, suggesting the production of mucous substances. Recently, these substances were differentiated according to modern molecular classifications. Expression studies detected mRNA for MUC1, MUC4, MUC5AC, MUC5B, MUC6, and MUC7, whereas MUC2 transcripts were absent in all samples investigated. Immunohistochemistry revealed membrane-bound MUC1 at the apical surface of acinar cells, MUC5AC associated with goblet cells of excretory ducts, MUC5B and MUC7 in the cytoplasm of acinar cells, and MUC7 also in epithelial cells of excretory ducts. MUC2 (RT-PCR negative) and MUC6 (RT-PCR positive) were not detectable by immunohistochemistry. MUC4 mRNA was present in all samples from patients treated for dry eye but only in 6 of 30 glands from individuals who did not receive treatment with artificial tears. Dot-blot analyses clearly revealed increased amounts of MUC4, MUC5AC and MUC5B in the glands of elderly women who received treatment for dry eye as compared to the remaining samples. These results confirm that the human lacrimal gland synthesizes a spectrum of mucins, some of which might be involved in the pathophysiology of dry eye syndrome.

  12. Portable containment sleever apparatus

    DOEpatents

    Rea, Michael J.; Brown, Roger A.

    2000-01-01

    A sleever apparatus includes an inner member with a central passage through which an item to be sleeved is passed. An outer member surrounds the inner member and defines a space between the members for holding a supply of containment material, which is preferably plastic sleeving. The apparatus has a handle which allows a user to hold the apparatus and walk the apparatus along the length of the item to be sleeved. As the user passes the item through the sleever apparatus, the containment material exits through a slit at one end of the apparatus in order to contain the item. The sleever apparatus may be formed of disposable materials, such as cardboard, and may be intended for a single use application. Alternatively, the sleever apparatus may be comprised of more permanent materials such as PVC or fiberglass. The sleever apparatus may include a serrated end for cutting the containment material and may include appropriate tubing and valves for either directing an inert gas into the containment material around the item or for withdrawing air from within the containment material in order to create a vacuum. In one embodiment, the sleever apparatus has a cartridge that can be replaced with another cartridge once the supply of the containment material has been depleted.

  13. Apparatus Notes.

    ERIC Educational Resources Information Center

    Eaton, Bruce G., Ed.

    1978-01-01

    Describes three pieces of scientific apparatus and their demonstrational use: a high temperature apparatus for positron annihilation studies, a digitally synthesized classroom variable star, and a demonstration of plasma laser-beam focusing using paint stripper flames. (GA)

  14. NMR logging apparatus

    DOEpatents

    Walsh, David O; Turner, Peter

    2014-05-27

    Technologies including NMR logging apparatus and methods are disclosed. Example NMR logging apparatus may include surface instrumentation and one or more downhole probes configured to fit within an earth borehole. The surface instrumentation may comprise a power amplifier, which may be coupled to the downhole probes via one or more transmission lines, and a controller configured to cause the power amplifier to generate a NMR activating pulse or sequence of pulses. Impedance matching means may be configured to match an output impedance of the power amplifier through a transmission line to a load impedance of a downhole probe. Methods may include deploying the various elements of disclosed NMR logging apparatus and using the apparatus to perform NMR measurements.

  15. [Ocular surface system integrity].

    PubMed

    Safonova, T N; Pateyuk, L S

    2015-01-01

    The interplay of different structures belonging to either the anterior segment of the eye or its accessory visual apparatus, which all share common embryological, anatomical, functional, and physiological features, is discussed. Explanation of such terms, as ocular surface, lacrimal functional unit, and ocular surface system, is provided.

  16. Borehole sealing method and apparatus

    DOEpatents

    Hartley, James N.; Jansen, Jr., George

    1977-01-01

    A method and apparatus is described for sealing boreholes in the earth. The borehole is blocked at the sealing level, and a sealing apparatus capable of melting rock and earth is positioned in the borehole just above seal level. The apparatus is heated to rock-melting temperature and powdered rock or other sealing material is transported down the borehole to the apparatus where it is melted, pooling on the mechanical block and allowed to cool and solidify, sealing the hole. Any length of the borehole can be sealed by slowly raising the apparatus in the borehole while continuously supplying powdered rock to the apparatus to be melted and added to the top of the column of molten and cooling rock, forming a continuous borehole seal. The sealing apparatus consists of a heater capable of melting rock, including means for supplying power to the heater, means for transporting powdered rock down the borehole to the heater, means for cooling the apparatus and means for positioning the apparatus in the borehole.

  17. Helium ionization detection apparatus

    NASA Technical Reports Server (NTRS)

    Nagai, R.

    1984-01-01

    In a gas chromatograph apparatus comprising a gas supply (He carrier gas), a sample injection apparatus, a chromatograph column, a He ion detector, and connecting tubes, a foreign gas (other than He) injection apparatus is installed between the sample injection apparatus and the detector. Mixing of the sample gas and foreign gas takes place readily, the sample gas is always maintained at a stable concentrator range, and accurate measurements are possible, especially at low sample gas concentrations.

  18. Evaluation of Accessory Lacrimal Gland in Muller's Muscle Conjunctival Resection Specimens for Precursor Cell Markers and Biological Markers of Dry Eye Disease.

    PubMed

    Ali, Marwan; Shah, Dhara; Pasha, Zeeshan; Jassim, Sarmad H; Jassim Jaboori, Assraa; Setabutr, Pete; Aakalu, Vinay K

    2017-04-01

    The accessory lacrimal glands (ALGs) are an understudied component of the tear functional unit, even though they are important in the development of dry eye syndrome (DES). To advance our understanding of aging changes, regenerative potential, and histologic correlates to human characteristics, we investigated human ALG tissue from surgical samples to determine the presence or absence of progenitor cell markers and lacrimal epithelial markers and to correlate marker expression to relevant patient characteristics. ALG tissues obtained from Muller's muscle conjunctival resection (MMCR) specimens were created using tissue microarrays (TMAs). Immunofluorescence staining of MMCR sections was performed using primary antibodies specific to cell protein markers. Cell marker localization in TMAs was then assessed by two blinded observers using a standardized scoring system. Patient characteristics including age, race, and status of ocular surface health were then compared against expression of stem cell markers. Human ALG expressed a number of epithelial markers, and in particular, histatin-1 was well correlated with the expression of epithelial markers and was present in most acini. In addition, we noted the presence of precursor cell markers nestin, ABCG2, and CD90 in ALG tissue. There was a decrease in precursor cell marker expression with increasing age. Finally, we noted that a negative association was present between histatin-1 expression and DES. Thus, we report for the first time that human ALG tissues contain precursor marker-positive cells and that this marker expression may decrease with increasing age. Moreover, histatin-1 expression may be decreased in DES. Future studies will be performed to use these cell markers to isolate and culture lacrimal epithelial cells from heterogeneous tissues, determine the relevance of histatin-1 expression to DES, and isolate candidate precursor cells from ALG tissue.

  19. Dacryocystography using cone beam CT in patients with lacrimal drainage system obstruction.

    PubMed

    Tschopp, Markus; Bornstein, Michael M; Sendi, Pedram; Jacobs, Reinhilde; Goldblum, David

    2014-01-01

    To assess the usefulness of cone beam CT (CBCT) for dacryocystography (DCG) using either direct syringing or passive application of contrast medium. Ten consecutive patients with epiphora who had CBCT-DCG in a sitting position were retrospectively analyzed. CBCT-DCGs were performed using 2 techniques: direct syringing with contrast medium or using the passive technique, where patients received 3 drops of contrast medium into the conjunctival sac before CBCT-DCG. Clinical and radiologic diagnoses were compared for both groups. The 10 patients (men = 3) had a mean age of 63.2 years. Both techniques proved to be simple procedures with good delineation of the bone, soft tissue, and the contrast medium in the lacrimal system. No side effects were noted. CBCT-DCG is a useful alternative to determine the localization of stenosis in patients with chronic epiphora.

  20. Apparatus for detecting leaks

    DOEpatents

    Booth, Eugene T.

    1976-02-24

    A method and apparatus for determining the position of and estimating the size of leaks in an evacuating apparatus comprising the use of a testing gas such as helium or hydrogen flowing around said apparatus whereby the testing gas will be drawn in at the site of any leaks.

  1. Microelectromechanical acceleration-sensing apparatus

    DOEpatents

    Lee, Robb M [Albuquerque, NM; Shul, Randy J [Albuquerque, NM; Polosky, Marc A [Albuquerque, NM; Hoke, Darren A [Albuquerque, NM; Vernon, George E [Rio Rancho, NM

    2006-12-12

    An acceleration-sensing apparatus is disclosed which includes a moveable shuttle (i.e. a suspended mass) and a latch for capturing and holding the shuttle when an acceleration event is sensed above a predetermined threshold level. The acceleration-sensing apparatus provides a switch closure upon sensing the acceleration event and remains latched in place thereafter. Examples of the acceleration-sensing apparatus are provided which are responsive to an acceleration component in a single direction (i.e. a single-sided device) or to two oppositely-directed acceleration components (i.e. a dual-sided device). A two-stage acceleration-sensing apparatus is also disclosed which can sense two acceleration events separated in time. The acceleration-sensing apparatus of the present invention has applications, for example, in an automotive airbag deployment system.

  2. Pipe crawler apparatus

    DOEpatents

    Hovis, Gregory L.; Erickson, Scott A.; Blackmon, Bruce L.

    2002-01-01

    A pipe crawler apparatus particularly useful for 3-inch and 4-inch diameter pipes is provided. The pipe crawler apparatus uses a gripping apparatus in which a free end of a piston rod is modified with a bearing retaining groove. Bearings, placed within the groove, are directed against a camming surface of three respective pivoting support members. The non-pivoting ends of the support members carry a foot-like gripping member that, upon pivoting of the support member, engages the interior wall of the pipe.

  3. Mirror plasma apparatus

    DOEpatents

    Moir, Ralph W.

    1981-01-01

    A mirror plasma apparatus which utilizes shielding by arc discharge to form a blanket plasma and lithium walls to reduce neutron damage to the wall of the apparatus. An embodiment involves a rotating liquid lithium blanket for a tandem mirror plasma apparatus wherein the first wall of the central mirror cell is made of liquid lithium which is spun with angular velocity great enough to keep the liquid lithium against the first material wall, a blanket plasma preventing the lithium vapor from contaminating the plasma.

  4. Polarization Imaging Apparatus

    NASA Technical Reports Server (NTRS)

    Zou, Yingyin K.; Chen, Qiushui

    2010-01-01

    A polarization imaging apparatus has shown promise as a prototype of instruments for medical imaging with contrast greater than that achievable by use of non-polarized light. The underlying principles of design and operation are derived from observations that light interacts with tissue ultrastructures that affect reflectance, scattering, absorption, and polarization of light. The apparatus utilizes high-speed electro-optical components for generating light properties and acquiring polarization images through aligned polarizers. These components include phase retarders made of OptoCeramic (registered TradeMark) material - a ceramic that has a high electro-optical coefficient. The apparatus includes a computer running a program that implements a novel algorithm for controlling the phase retarders, capturing image data, and computing the Stokes polarization images. Potential applications include imaging of superficial cancers and other skin lesions, early detection of diseased cells, and microscopic analysis of tissues. The high imaging speed of this apparatus could be beneficial for observing live cells or tissues, and could enable rapid identification of moving targets in astronomy and national defense. The apparatus could also be used as an analysis tool in material research and industrial processing.

  5. Evaluation of Accessory Lacrimal Gland in Muller’s Muscle Conjunctival Resection Specimens for Precursor Cell Markers and Biological Markers of Dry Eye Disease

    PubMed Central

    Ali, Marwan; Shah, Dhara; Pasha, Zeeshan; Jassim, Sarmad H.; Jaboori, Assraa Jassim; Setabutr, Pete; Aakalu, Vinay K.

    2017-01-01

    Purpose The accessory lacrimal glands (ALG) are an understudied component of the tear functional unit, even though they are important in the development of dry eye syndrome (DES). To advance our understanding of aging changes, regenerative potential and histologic correlates to human characteristics, we investigated human ALG tissue from surgical samples to determine the presence or absence of progenitor cell markers and lacrimal epithelial markers and to correlate marker expression to relevant patient characteristics. Materials and Methods ALG tissues obtained from Muller’s Muscle Conjunctival Resection (MMCR) specimens were created using tissue microarrays (TMAs). Immunofluorescence staining of MMCR sections was performed using primary antibodies specific to cell protein markers. Cell marker localization in TMAs was then assessed by two blinded observers using a standardized scoring system. Patient characteristics including age, race, and status of ocular surface health were then compared against expression of stem cell markers. Results Human ALG expressed a number of epithelial markers, and in particular, histatin-1 was well correlated with the expression of epithelial markers and was present in most acini. In addition, we noted the presence of precursor cell markers nestin, ABCG2 and CD90 in ALG tissue. There was a decrease in precursor cell marker expression with increasing age. Finally, we noted that a negative association was present between histatin-1 expression and DES. Conclusions Thus, we report for the first time that human ALG tissues contain precursor marker positive cells and that this marker expression may decrease with increasing age. Moreover, histatin-1 expression may be decreased in DES. Future studies will be performed to use these cell markers to isolate and culture lacrimal epithelial cells from heterogeneous tissues, determine the relevance of histatin-1 expression to DES and isolate candidate precursor cells from ALG tissue. PMID:27612554

  6. Morphology and function of lacrimal gland acinar cells in primary culture.

    PubMed

    Hann, L E; Tatro, J B; Sullivan, D A

    1989-01-01

    The objectives of the current investigation were fourfold: (1) to establish an effective procedure for the isolation of acinar cells from the rat lacrimal gland; (2) to evaluate the functional capacity of freshly isolated cells; (3) to determine defined culture conditions which permit maintenance of viable, differentiated cells, as well as secretory component (SC) production, during long-term culture; and (4) to characterize the morphological features of cultured cells. Acinar cells were isolated by serial incubation of gland fragments in chelating and enzymatic solutions, followed by centrifugation through a Ficoll gradient. The yield of viable cells/gland appeared to be age-dependent: cell recovery was inversely proportional to the age of the animals. Immunofluorescence analysis of freshly isolated cells showed the presence of SC, the IgA antibody receptor, within isolated cells. In addition, experiments with a labeled analog (Nle4-D-Phe7-alpha MSH) of alpha-melanocyte-stimulating hormone (alpha-MSH) demonstrated specific binding sites on freshly isolated cells; alpha-MSH is a known modulator of acinar protein secretion. Maximum binding of the alpha-MSH analog occurred within 30 min, was dependent upon cell density and was reduced by coincubation with unlabeled alpha-MSH. To determine the culture requirements of acinar cells, cells were cultured on a variety of substrates (plastic or modified plastic [Primaria], coated with or without extracellular matrix [Matrigel]) in the presence or absence of various supplements and/or fetal calf serum (FCS) for 0.7 to 3.5 weeks. Cell attachment, function and long-term viability required an extracellular matrix. Moreover, in long term cultures (25 days), acinar cell attachment was enhanced by the inclusion of supplements to media containing 10% FCS. Replacement of serum with fibroblast growth factor, high-density lipoprotein and an increased concentration of epidermal growth factor resulted in a distinct "cobblestone

  7. Not All Lacrimal Epithelial Cells are Created Equal—Heterogeneity of the Rabbit Lacrimal Gland and Differential Secretion

    PubMed Central

    Ding, Chuanqing; Huang, Jianyan; MacVeigh-Aloni, Michelle; Lu, Michael

    2013-01-01

    Aims To test the hypotheses that some epithelial cells in the rabbit lacrimal gland (LG) are mucin-secreting cells that are also particularly rich in aquaporin 5 (AQP5) and sodium potassium ATPase β1 subunit (NKAβ1), LG-secreted mucins contribute to the total mucin pool in tear film, and that the rabbit LG is a heterogenic gland where proteins secreted in response to different agonists are varied. Materials and methods LGs were obtained from adult female rabbits and processed for paraffin sections for hematoxylin and eosin (HE) staining, periodic acid-Schiff (PAS), mucicarmine, and Alcian blue (pH 0.4, 1.0, and 2.5) for the detection of mucins. Serial sections were used for immunohistochemistry (IHC) and PAS. LG lysates and fluids were assayed by dot blot for detection of mucins, and by SDS-PAGE to detect differences in protein profiles of LG fluids stimulated by different agonists. Results HE staining demonstrated that the LG is a heterogeneous gland where most epithelial cells are serous, while all duct cells are mucous cells. Some acini and individual acinar cells within serous acini are also mucous or seromucous cells and these cells are particularly rich in AQP5 and NKAβ1. Dot blot assay showed the presence of mucins in the LG fluids. The protein profiles of LG fluids from pilocarpine, phenylephrine, and isoproterenol varied significantly, particularly in the mid range. Conclusions Our data indicated that the rabbit LG is a heterogeneous gland that is composed of both serous and mucin-secreting cells, and mucins produced by the LG contribute to the mucin pool in the tear film. The heterogeneity of the rabbit LG supports the notion of differential secretion, i.e. the volume and composition of the LG fluids vary depending on various circumstances in the ocular surface and the body’s needs. PMID:21999223

  8. Microarray analysis of the rat lacrimal gland following the loss of parasympathetic control of secretion

    PubMed Central

    Nguyen, Doan H.; Toshida, Hiroshi; Schurr, Jill; Beuerman, Roger W.

    2010-01-01

    Previous studies showed that loss of muscarinic parasympathetic input to the lacrimal gland (LG) leads to a dramatic reduction in tear secretion and profound changes to LG structure. In this study, we used DNA microarrays to examine the regulation of the gene expression of the genes for secretory function and organization of the LG. Long-Evans rats anesthetized with a mixture of ketamine/xylazine (80:10 mg/kg) underwent unilateral sectioning of the greater superficial petrosal nerve, the input to the pterygopalatine ganglion. After 7 days, tear secretion was measured, the animals were killed, and structural changes in the LG were examined by light microscopy. Total RNA from control and experimental LGs (n = 5) was used for DNA microarray analysis employing the U34A GeneChip. Three statistical algorithms (detection, change call, and signal log ratio) were used to determine differential gene expression using the Microarray Suite (5.0) and Data Mining Tools (3.0). Tear secretion was significantly reduced and corneal ulcers developed in all experimental eyes. Light microscopy showed breakdown of the acinar structure of the LG. DNA microarray analysis showed downregulation of genes associated with the endoplasmic reticulum and Golgi, including genes involved in protein folding and processing. Conversely, transcripts for cytoskeleton and extracellular matrix components, inflammation, and apoptosis were upregulated. The number of significantly upregulated genes (116) was substantially greater than the number of downregulated genes (49). Removal of the main secretory input to the rat LG resulted in clinical symptoms associated with severe dry eye. Components of the secretory pathway were negatively affected, and the increase in cell proliferation and inflammation may lead to loss of organization in the parasympathectomized lacrimal gland. PMID:15084711

  9. Light shielding apparatus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Richard Dean; Thom, Robert Anthony

    A light shielding apparatus for blocking light from reaching an electronic device, the light shielding apparatus including left and right support assemblies, a cross member, and an opaque shroud. The support assemblies each include primary support structure, a mounting element for removably connecting the apparatus to the electronic device, and a support member depending from the primary support structure for retaining the apparatus in an upright orientation. The cross member couples the left and right support assemblies together and spaces them apart according to the size and shape of the electronic device. The shroud may be removably and adjustably connectablemore » to the left and right support assemblies and configured to take a cylindrical dome shape so as to form a central space covered from above. The opaque shroud prevents light from entering the central space and contacting sensitive elements of the electronic device.« less

  10. Staging and follow-up of lacrimal gland carcinomas by 18F-FDG PET/CT imaging.

    PubMed

    Tafti, Bashir Akhavan; Shaba, Wisam; Li, Yuxin; Yevdayev, Ella; Berenji, Gholam Reza

    2012-10-01

    A 74-year-old man with right eye proptosis, diplopia, and orbital discomfort for 3 to 4 months underwent biopsy, the specimen of which showed transitional cell carcinoma of the lacrimal gland. 18F-FDG PET/CT was also performed for staging purposes. Six months after orbital exenteration, a follow-up CT scan demonstrated soft tissue thickening along the nasal bridge but could not differentiate between postsurgical changes and cancer recurrence. A concurrent PET/CT scan did not show any evidence of abnormal metabolic activity, further emphasizing the higher accuracy of PET/CT in staging and restaging of head and neck cancers. An annual follow-up scan was still negative for active disease.

  11. AUTOMATIC COUNTING APPARATUS

    DOEpatents

    Howell, W.D.

    1957-08-20

    An apparatus for automatically recording the results of counting operations on trains of electrical pulses is described. The disadvantages of prior devices utilizing the two common methods of obtaining the count rate are overcome by this apparatus; in the case of time controlled operation, the disclosed system automatically records amy information stored by the scaler but not transferred to the printer at the end of the predetermined time controlled operations and, in the case of count controlled operation, provision is made to prevent a weak sample from occupying the apparatus for an excessively long period of time.

  12. Nuclear reactor apparatus

    DOEpatents

    Wade, Elman E.

    1978-01-01

    A lifting, rotating and sealing apparatus for nuclear reactors utilizing rotating plugs above the nuclear reactor core. This apparatus permits rotation of the plugs to provide under the plug refueling of a nuclear core. It also provides a means by which positive top core holddown can be utilized. Both of these operations are accomplished by means of the apparatus lifting the top core holddown structure off the nuclear core while stationary, and maintaining this structure in its elevated position during plug rotation. During both of these operations, the interface between the rotating member and its supporting member is sealingly maintained.

  13. Thermal protection apparatus

    DOEpatents

    Bennett, Gloria A.; Elder, Michael G.; Kemme, Joseph E.

    1985-01-01

    An apparatus which thermally protects sensitive components in tools used in a geothermal borehole. The apparatus comprises a Dewar within a housing. The Dewar contains heat pipes such as brass heat pipes for thermally conducting heat from heat sensitive components to a heat sink such as ice.

  14. Waste Water Treatment Apparatus and Methods

    NASA Technical Reports Server (NTRS)

    Plawsky, Joel L. (Inventor); Paccione, John D. (Inventor); Littman, Howard (Inventor)

    2014-01-01

    An improved draft tube spout fluid bed (DTSFB) mixing, handling, conveying, and treating apparatus and systems, and methods for operating are provided. The apparatus and systems can accept particulate material and pneumatically or hydraulically conveying the material to mix and/or treat the material. In addition to conveying apparatus, a collection and separation apparatus adapted to receive the conveyed particulate material is also provided. The collection apparatus may include an impaction plate against which the conveyed material is directed to improve mixing and/or treatment. The improved apparatus are characterized by means of controlling the operation of the pneumatic or hydraulic transfer to enhance the mixing and/or reacting by controlling the flow of fluids, for example, air, into and out of the apparatus. The disclosed apparatus may be used to mix particulate material, for example, mortar; react fluids with particulate material; coat particulate material, or simply convey particulate material.

  15. Apparatus for assembling space structure

    NASA Technical Reports Server (NTRS)

    Johnston, J. D.; Tuggle, R. H., Jr.; Burch, J. L.; Clark, K. H. (Inventor)

    1978-01-01

    An apparatus for producing a structure in outer space from rolls of prepunched ribbon or sheet material that are transported from the earth to the apparatus located in outer space is described. The apparatus spins the space structure similar to a spider spinning a web utilizing the prepunched ribbon material. The prepunched ribbon material is fed through the apparatus and is shaped into a predetermined channel-shaped configuration. Trusses are punched out of the ribbon and are bent downwardly and attached to a track which normally is a previously laid sheet of material. The size of the overall space structure may be increased by merely attaching an additional roll of sheet material to the apparatus.

  16. Archimedes force on Casimir apparatus

    NASA Astrophysics Data System (ADS)

    Shevchenko, V.; Shevrin, E.

    2016-11-01

    The talk addresses a problem of Casimir apparatus in weak gravitational field, surrounded by a dense medium. The falling of the apparatus has to be governed by the equivalence principle, taking into account proper contributions to the weight of the apparatus from its material part and from distorted quantum fields. We discuss general ex pression for the corresponding force in terms of the effective action. By way of example we compute explicit expression for Archimedes force, acting on the Casimir apparatus of finite size, immersed into thermal bath of free scalar field. It is shown that besides universal term, proportional to the volume of the apparatus, there are non-universal quantum corrections, depending on the boundary conditions.

  17. Archimedes force on Casimir apparatus

    NASA Astrophysics Data System (ADS)

    Shevchenko, Vladimir; Shevrin, Efim

    2016-08-01

    This paper addresses a problem of Casimir apparatus in dense medium, put in weak gravitational field. The falling of the apparatus has to be governed by the equivalence principle with proper account for contributions to the weight of the apparatus from its material part and from distorted quantum fields. We discuss general expression for the corresponding force in metric with cylindrical symmetry. By way of example, we compute explicit expression for Archimedes force, acting on the Casimir apparatus of finite size, immersed into thermal bath of free scalar field. It is shown that besides universal term, proportional to the volume of the apparatus, there are non-universal quantum corrections, depending on the boundary conditions.

  18. Conduit grinding apparatus

    DOEpatents

    Nachbar, Henry D.; Korytkowski, Alfred S.

    1991-01-01

    A grinding apparatus for grinding the interior portion of a valve stem receiving area of a valve. The apparatus comprises a faceplate, a plurality of cams mounted to an interior face of the faceplate, a locking bolt to lock the faceplate at a predetermined position on the valve, a movable grinder and a guide tube for positioning an optical viewer proximate the area to be grinded. The apparatus can either be rotated about the valve for grinding an area of the inner diameter of a valve stem receiving area or locked at a predetermined position to grind a specific point in the receiving area.

  19. Speckle-Suppression Apparatus

    NASA Technical Reports Server (NTRS)

    Taback, Israel

    1989-01-01

    Technique and apparatus developed to reduce speckle in unmodulated laser pulses, using reduced number of optical fibers. Expected to decrease costs of bundles of optical fibers used to transmit unmodulated laser pulses. New apparatus reduces speckle in optically transmitted, unmodulated laser input pulse by introducing number of independent delays into pulse.

  20. Automatic insulation resistance testing apparatus

    DOEpatents

    Wyant, Francis J.; Nowlen, Steven P.; Luker, Spencer M.

    2005-06-14

    An apparatus and method for automatic measurement of insulation resistances of a multi-conductor cable. In one embodiment of the invention, the apparatus comprises a power supply source, an input measuring means, an output measuring means, a plurality of input relay controlled contacts, a plurality of output relay controlled contacts, a relay controller and a computer. In another embodiment of the invention the apparatus comprises a power supply source, an input measuring means, an output measuring means, an input switching unit, an output switching unit and a control unit/data logger. Embodiments of the apparatus of the invention may also incorporate cable fire testing means. The apparatus and methods of the present invention use either voltage or current for input and output measured variables.

  1. Microelectromechanical reciprocating-tooth indexing apparatus

    DOEpatents

    Allen, James J.

    1999-01-01

    An indexing apparatus is disclosed that can be used to rotate a gear or move a rack in a precise, controllable manner. The indexing apparatus, based on a reciprocating shuttle driven by one or more actuators, can be formed either as a micromachine, or as a millimachine. The reciprocating shuttle of the indexing apparatus can be driven by a thermal, electrostatic or electromagnetic actuator, with one or more wedge-shaped drive teeth of the shuttle being moveable to engage and slide against indexing teeth on the gear or rack, thereby moving the gear or rack. The indexing apparatus can be formed by either surface micromachining processes or LIGA processes, depending on the size of the apparatus that is to be formed.

  2. Thermal protection apparatus

    DOEpatents

    Bennett, G.A.; Elder, M.G.; Kemme, J.E.

    1984-03-20

    The disclosure is directed to an apparatus for thermally protecting sensitive components in tools used in a geothermal borehole. The apparatus comprises a Dewar within a housing. The Dewar contains heat pipes such as brass heat pipes for thermally conducting heat from heat sensitive components such as electronics to a heat sink such as ice.

  3. miR-24-3p Suppresses Malignant Behavior of Lacrimal Adenoid Cystic Carcinoma by Targeting PRKCH to Regulate p53/p21 Pathway.

    PubMed

    Zhang, Ming-Xue; Zhang, Jie; Zhang, Hong; Tang, Hua

    2016-01-01

    MicroRNA (miRNA) may function as an oncogene or a tumor suppressor in tumorigenesis. However, the mechanism of miRNAs in adenoid cystic carcinoma (ACC) is unclear. Here, we provide evidence that miR-24-3p was downreglated and functions as a tumor suppressor in human lacrimal adenoid cystic carcinoma by suppressing proliferation and migration/invasion while promoting apoptosis. miR-24-3p down-regulated protein kinase C eta (PRKCH) by binding to its untranslated region (3'UTR). PRKCH increased the of the cell growth and migration/invasion in ACC cells and suppressed the expression of p53 and p21 in both mRNA and protein level. The overexpression of miR-24-3p decreased its malignant phenotype. Ectopic expression of PRKCH counteracted the suppression of malignancy induced by miR-24-3p, as well as ectopic expression of miR-24-3p rescued the suppression of PRKCH in the p53/p21 pathway. These results suggest that miR-24-3p promotes the p53/p21 pathway by down-regulating PRKCH expression in lacrimal adenoid cystic carcinoma cells.

  4. Control apparatus

    NASA Technical Reports Server (NTRS)

    Derkacs, Thomas (Inventor); Fetheroff, Charles W. (Inventor); Matay, Istvan M. (Inventor); Toth, Istvan J. (Inventor)

    1982-01-01

    Although the method and apparatus of the present invention can be utilized to apply either a uniform or a nonuniform covering of material over many different workpieces, the apparatus (20) is advantageously utilized to apply a thermal barrier covering (64) to an airfoil (22) which is used in a turbine engine. The airfoil is held by a gripper assembly (86) while a spray gun (24) is effective to apply the covering over the airfoil. When a portion of the covering has been applied, a sensor (28) is utilized to detect the thickness of the covering. A control apparatus (32) compares the thickness of the covering of material which has been applied with the desired thickness and is subsequently effective to regulate the operation of the spray gun to adaptively apply a covering of a desired thickness with an accuracy of at least plus or minus 0.0015 inches (1.5 mils) despite unanticipated process variations.

  5. Aerosol distribution apparatus

    DOEpatents

    Hanson, W.D.

    An apparatus for uniformly distributing an aerosol to a plurality of filters mounted in a plenum, wherein the aerosol and air are forced through a manifold system by means of a jet pump and released into the plenum through orifices in the manifold. The apparatus allows for the simultaneous aerosol-testing of all the filters in the plenum.

  6. Bi-stem gripping apparatus

    NASA Technical Reports Server (NTRS)

    Sanders, Fred G. (Inventor)

    1988-01-01

    This invention relates to devices which grip cylindrical structures and more particularly to a device which has three arcuate gripping members having frictional surfaces for gripping and compressing a bi-stem. The bi-stem gripping apparatus is constructed having a pair of side gripping members, and an intermediate gripping member disposed between them. Sheets of a gum stock silicone rubber with frictional gripping surfaces are bonded to the inner region of the gripping members and provide frictional engagement between the bi-stem and the apparatus. A latch secures the gripping apparatus to a bi-stem, and removable handles are attached, allowing an astronaut to pull the bi-stem from its cassette. A tethering ring on the outside of the gripping apparatus provides a convenient point to which a lanyard may be attached.

  7. Monolith filter apparatus and membrane apparatus, and method using same

    DOEpatents

    Goldsmith, Robert L [Wayland, MA

    2012-04-03

    A filtration apparatus that separates a liquid feedstock mixed with a gas into filtrate and retentate, the apparatus including at least one filtration device comprised of at least one monolith segment of porous material that defines a plurality of passageways extending longitudinally from a feed face of the structure to a retentate end face. The filtration device contains at least one filtrate conduit within it for carrying filtrate toward a filtrate collection zone, the filtrate conduit providing a path of lower flow resistance than that of alternative flow paths through the porous material of the device. The filtration device can also be utilized as a membrane support for a device for microfiltration, ultrafiltration, nanofiltration, reverse osmosis, or pervaporation. Also disclosed is a method for using such a filtration apparatus.

  8. [The cultivation and identification of lacrimal gland adenoid cystic cancer stem cells].

    PubMed

    Lyu, Jianmei; He, Yanjin; Xie, Lianfeng; Liu, Xun; Zhu, Limin

    2015-10-01

    To isolate and cultivate the Lacrimal gland Adenoid Cystic Carcinoma cells line, study Cancer Stem Cells properties. Experimental study. Lacrimal gland adenoid cystic carcinoma cancer stem cells were cultivated in serum-free suspension culture and the morphological changes were observed. Cells were divided into two groups, the LACC-CSC experimental group and the LACC control group. The flow cytometry instrument was used to detect the expression of classical stem cell markers CD133 and ABCG2. Transwell chamber was used to detect the cancer stem cell aggressivity and differentiated into the vascular endothelial cells. The tumorigenic force in vitro xenotransplantation were applied. LACC cells can grow suspensively after vaccinated in serum free medium and form tumor microspheres after 10-12 days. Flow cytometry experiments showed that the expression ratio of stem cell markers CD133 in LACC-CSC was (35.67 ± 6.86)%, significantly different to LACC with (0.46 ± 0.48)%, (t = 8.867, P < 0.05). Similarly, the expression ratio of stem cell marker ABCG2 in LACC-CSC was (39.99 ± 4.54)%, significantly different to LACC with (6.75 ± 1.34)%, (t = -9.932, P < 0.05). In vitro experiment of Matrigel invasion, LACC-CSC went through the matrigel basement membrane averagely (32.60 ± 8.79)/HP contrary to LACC with average (10.20 ± 2.77)/HP after 24 hours, showing statistically significance (t = 5.433, P < 0.05) between the two groups. After training for 48 hours, the difference between two groups was still obvious (t = 5.779, P < 0.05) with LACC-CSC average (62.60 ± 4.83)/HP to LACC (44.00 ± 5.34)/HP. When induced by serum medium containing VEGF and bFGF, LACC-CSC grew adherent gradually and cell morphological changes occurred after continuous induction to long spindle cells. When cultured into three-dimensional matrix structure they formed vessel samples and expressed vascular endothelial marker CD31 and CD34. Transplanted tumor in vitro experiment, mice of LACC-CSC group grew

  9. Irradiation apparatus

    DOEpatents

    Goldie, C.H.; Fernald, R.A.

    1974-01-29

    An apparatus for introducing ionizing radiation into compressed gas insulation systems, such as high-voltage generators or transmission lines to smooth out electrical discontinuities, particularly those caused by foreign particulates that produce high gradients, and to increase the voltage holding capability of the system is described. The apparatus of the invention may also be used to regulate and stabilize the voltage of the system by varying the amount of applied load. A corona discharge device may also be used in conjunction with the invention. (Official Gazette)

  10. Apparatus for transporting hazardous materials

    DOEpatents

    Osterman, Robert A.; Cox, Robert

    1992-01-01

    An apparatus and method are provided for selectively receiving, transporting, and releasing one or more radioactive or other hazardous samples for analysis on a differential thermal analysis (DTA) apparatus. The apparatus includes a portable sample transporting apparatus for storing and transporting the samples and includes a support assembly for supporting the transporting apparatus when a sample is transferred to the DTA apparatus. The transporting apparatus includes a storage member which includes a plurality of storage chambers arrayed circumferentially with respect to a central axis. An adjustable top door is located on the top side of the storage member, and the top door includes a channel capable of being selectively placed in registration with the respective storage chambers thereby permitting the samples to selectively enter the respective storage chambers. The top door, when closed, isolates the respective samples within the storage chambers. A plurality of spring-biased bottom doors are located on the bottom sides of the respective storage chambers. The bottom doors isolate the samples in the respective storage chambers when the bottom doors are in the closed position. The bottom doors permit the samples to leave the respective storage chambers from the bottom side when the respective bottom doors are in respective open positions. The bottom doors permit the samples to be loaded into the respective storage chambers after the analysis for storage and transport to a permanent storage location.

  11. TRANSFORMER APPARATUS

    DOEpatents

    Wolfgang, F.; Nicol, J.

    1962-11-01

    Transformer apparatus is designed for measuring the amount of a paramagnetic substance dissolved or suspended in a diamagnetic liquid. The apparatus consists of a cluster of tubes, some of which are closed and have sealed within the diamagnetic substance without any of the paramagnetic material. The remaining tubes are open to flow of the mix- ture. Primary and secondary conductors are wrapped around the tubes in such a way as to cancel noise components and also to produce a differential signal on the secondaries based upon variations of the content of the paramagnetic material. (AEC)

  12. Cleaning method and apparatus

    DOEpatents

    Jackson, D.D.; Hollen, R.M.

    1981-02-27

    A method of very thoroughly and quikcly cleaning a guaze electrode used in chemical analyses is given, as well as an automobile cleaning apparatus which makes use of the method. The method generates very little waste solution, and this is very important in analyzing radioactive materials, especially in aqueous solutions. The cleaning apparatus can be used in a larger, fully automated controlled potential coulometric apparatus. About 99.98% of a 5 mg plutonium sample was removed in less than 3 minutes, using only about 60 ml of rinse solution and two main rinse steps.

  13. Cleaning method and apparatus

    DOEpatents

    Jackson, Darryl D.; Hollen, Robert M.

    1983-01-01

    A new automatable cleaning apparatus which makes use of a method of very thoroughly and quickly cleaning a gauze electrode used in chemical analyses is given. The method generates very little waste solution, and this is very important in analyzing radioactive materials, especially in aqueous solutions. The cleaning apparatus can be used in a larger, fully automated controlled potential coulometric apparatus. About 99.98% of a 5 mg. plutonium sample was removed in less than 3 minutes, using only about 60 ml. of rinse solution and two main rinse steps.

  14. Apparatus for Teaching Physics.

    ERIC Educational Resources Information Center

    Gottlieb, Herbert H., Ed.

    1981-01-01

    Describes: (1) a variable inductor suitable for an inductance-capacitance bridge consisting of a fixed cylindrical solenoid and a moveable solenoid; (2) long-range apparatus for demonstrating falling bodies; and (3) an apparatus using two lasers to demonstrate ray optics. (SK)

  15. Distillation Apparatuses Using Household Items

    NASA Astrophysics Data System (ADS)

    Campanizzi, Danielle R. D.; Mason, Brenda; Hermann, Christine K. F.

    1999-08-01

    A simple apparatus to demonstrate distillation principles can be very difficult to build without the specialty glassware found in chemistry laboratories. We have built inexpensive but effective distillation apparatuses from equipment that can be easily purchased at local department, grocery, or hardware stores. In one apparatus, colored water is heated to boiling and the condensed vapors drip into another container. In another apparatus, acetone is heated to boiling with hot water and the acetone vapors condense onto a Styrofoam cup. The Styrofoam cup is softened by the acetone and collapses. Rubbing alcohol can be used instead of acetone, but the cup is not softened and the boiling point is much higher. Both apparatuses can be used in a classroom. Both are simple, cost-effective ways of demonstrating distillation, evaporation, and condensation. They would be ideal to use in elementary and middle school classrooms when explaining these concepts.

  16. Gas turbine sealing apparatus

    DOEpatents

    Marra, John Joseph; Wessell, Brian J.; Liang, George

    2013-03-05

    A sealing apparatus in a gas turbine. The sealing apparatus includes a seal housing apparatus coupled to a disc/rotor assembly so as to be rotatable therewith during operation of the gas turbine. The seal housing apparatus comprises a base member, a first leg portion, a second leg portion, and spanning structure. The base member extends generally axially between forward and aft rows of rotatable blades and is positioned adjacent to a row of stationary vanes. The first leg portion extends radially inwardly from the base member and is coupled to the disc/rotor assembly. The second leg portion is axially spaced from the first leg portion, extends radially inwardly from the base member, and is coupled to the disc/rotor assembly. The spanning structure extends between and is rigidly coupled to each of the base member, the first leg portion, and the second leg portion.

  17. Apparatus for assembly of microelectronic devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Okandan, Murat; Nielson, Gregory N.; Cruz-Campa, Jose Luis

    An apparatus including a carrier substrate configured to move a microelectronic device. The apparatus further includes a rotatable body configured to receive the microelectronic device. Additionally, the apparatus includes a second substrate configured to receive the microelectronic device from the rotatable body.

  18. 47 CFR 32.2311 - Station apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 2 2011-10-01 2011-10-01 false Station apparatus. 32.2311 Section 32.2311... FOR TELECOMMUNICATIONS COMPANIES Instructions for Balance Sheet Accounts § 32.2311 Station apparatus. (a) This account shall include the original cost of station apparatus, including teletypewriter...

  19. 47 CFR 32.2311 - Station apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Station apparatus. 32.2311 Section 32.2311... FOR TELECOMMUNICATIONS COMPANIES Instructions for Balance Sheet Accounts § 32.2311 Station apparatus. (a) This account shall include the original cost of station apparatus, including teletypewriter...

  20. Flexible ultrasonic pipe inspection apparatus

    DOEpatents

    Jenkins, C.F.; Howard, B.D.

    1998-06-23

    A flexible, modular ultrasonic pipe inspection apparatus, comprises a flexible, hollow shaft that carries a plurality of modules, including at least one rotatable ultrasonic transducer, a motor/gear unit, and a position/signal encoder. The modules are connected by flexible knuckle joints that allow each module of the apparatus to change its relative orientation with respect to a neighboring module, while the shaft protects electrical wiring from kinking or buckling while the apparatus moves around a tight corner. The apparatus is moved through a pipe by any suitable means, including a tether or drawstring attached to the nose or tail, differential hydraulic pressure, or a pipe pig. The rotational speed of the ultrasonic transducer and the forward velocity of the apparatus are coordinated so that the beam sweeps out the entire interior surface of the pipe, enabling the operator to accurately assess the condition of the pipe wall and determine whether or not leak-prone corrosion damage is present. 7 figs.

  1. Flexible ultrasonic pipe inspection apparatus

    DOEpatents

    Jenkins, Charles F.; Howard, Boyd D.

    1998-01-01

    A flexible, modular ultrasonic pipe inspection apparatus, comprising a flexible, hollow shaft that carries a plurality of modules, including at least one rotatable ultrasonic transducer, a motor/gear unit, and a position/signal encoder. The modules are connected by flexible knuckle joints that allow each module of the apparatus to change its relative orientation with respect to a neighboring module, while the shaft protects electrical wiring from kinking or buckling while the apparatus moves around a tight corner. The apparatus is moved through a pipe by any suitable means, including a tether or drawstring attached to the nose or tail, differential hydraulic pressure, or a pipe pig. The rotational speed of the ultrasonic transducer and the forward velocity of the apparatus are coordinated so that the beam sweeps out the entire interior surface of the pipe, enabling the operator to accurately assess the condition of the pipe wall and determine whether or not leak-prone corrosion damage is present.

  2. Vacuum pump apparatus

    DOEpatents

    Batzer, Thomas H.; Call, Wayne R.

    1985-01-01

    An improved cryopumping apparatus which comprises a cryopumping space which may be alternately opened and closed from the surrounding area by moveable panels, trubular cryopanels within said cryopumping space through which a coolant such as liquid helium may be passed, and an apparatus for spraying liquid argon onto said cylindrical cryopanels in order to enhance the cryogenic entrapment of such low-z ions, atoms, and molecules as hydrogen and helium.

  3. Complete liquefaction methods and apparatus

    DOEpatents

    Turner, Terry D.; Wilding, Bruce M.

    2013-10-15

    A method and apparatus are described to provide complete gas utilization in the liquefaction operation from a source of gas without return of natural gas to the source thereof from the process and apparatus. The mass flow rate of gas input into the system and apparatus may be substantially equal to the mass flow rate of liquefied product output from the system, such as for storage or use.

  4. Method and apparatus for separating material

    DOEpatents

    Oder, Robin R.; Jamison, Russell E.

    2004-11-23

    An apparatus for sorting particles composed of a mixture of particles with differing physical and chemical characteristics. The apparatus includes a comminutor or a pulverizer for reducing the size of the particles. The apparatus includes a mechanism for separating undesired material from desired material.

  5. 21 CFR 868.5400 - Electroanesthesia apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Electroanesthesia apparatus. 868.5400 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5400 Electroanesthesia apparatus. (a) Identification. An electroanesthesia apparatus is a device used for the induction and maintenance of anesthesia...

  6. 21 CFR 868.5400 - Electroanesthesia apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electroanesthesia apparatus. 868.5400 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5400 Electroanesthesia apparatus. (a) Identification. An electroanesthesia apparatus is a device used for the induction and maintenance of anesthesia...

  7. 42 CFR 84.74 - Apparatus containers; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Apparatus containers; minimum requirements. 84.74...-Contained Breathing Apparatus § 84.74 Apparatus containers; minimum requirements. (a) Apparatus may be...) Containers supplied by the applicant for carrying or storing self-contained breathing apparatus will be...

  8. 42 CFR 84.74 - Apparatus containers; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Apparatus containers; minimum requirements. 84.74...-Contained Breathing Apparatus § 84.74 Apparatus containers; minimum requirements. (a) Apparatus may be...) Containers supplied by the applicant for carrying or storing self-contained breathing apparatus will be...

  9. 46 CFR 169.251 - Steering apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Steering apparatus. 169.251 Section 169.251 Shipping... Inspection and Certification Inspections § 169.251 Steering apparatus. At each inspection for certification and periodic inspection the steering apparatus is inspected and operationally tested to determine that...

  10. 46 CFR 169.251 - Steering apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Steering apparatus. 169.251 Section 169.251 Shipping... Inspection and Certification Inspections § 169.251 Steering apparatus. At each inspection for certification and periodic inspection the steering apparatus is inspected and operationally tested to determine that...

  11. Robot arm apparatus

    DOEpatents

    Nachbar, Henry D.

    1992-12-01

    A robot arm apparatus is provided for inspecting and/or maintaining an interior of a steam generator which has an outside wall and a port for accessing the interior of the steam generator. The robot arm apparatus includes a flexible movable conduit for conveying inspection and/or maintenance apparatus from outside the steam generator to the interior of the steam generator. The flexible conduit has a terminal working end which is translated into and around the interior of the steam generator. Three motors located outside the steam generator are employed for moving the terminal working end inside the steam generator in "x", "y", and "z" directions, respectively. Commonly conducted inspection and maintenance operations include visual inspection for damaged areas, water jet lancing for cleaning sludge deposits, core boring for obtaining sludge deposits, and scrubbing of internal parts.

  12. Passive orientation apparatus

    DOEpatents

    Spletzer, Barry L.; Fischer, Gary J.; Martinez, Michael A.

    2001-01-01

    An apparatus that can return a payload to a known orientation after unknown motion, without requiring external power or complex mechanical systems. The apparatus comprises a faceted cage that causes the system to rest in a stable position and orientation after arbitrary motion. A gimbal is mounted with the faceted cage and holds the payload, allowing the payload to move relative to the stable faceted cage. The payload is thereby placed in a known orientation by the interaction of gravity with the geometry of the faceted cage, the mass of the system, and the motion of the payload and gimbal. No additional energy, control, or mechanical actuation is required. The apparatus is suitable for use in applications requiring positioning of a payload to a known orientation after arbitrary or uncontrolled motion, including remote sensing and mobile robot applications.

  13. Robot arm apparatus

    DOEpatents

    Nachbar, Henry D.

    1992-01-01

    A robot arm apparatus is provided for inspecting and/or maintaining an interior of a steam generator which has an outside wall and a port for accessing the interior of the steam generator. The robot arm apparatus includes a flexible movable conduit for conveying inspection and/or maintenance apparatus from outside the steam generator to the interior of the steam generator. The flexible conduit has a terminal working end which is translated into and around the interior of the steam generator. Three motors located outside the steam generator are employed for moving the terminal working end inside the steam generator in "x", "y", and "z" directions, respectively. Commonly conducted inspection and maintenance operations include visual inspection for damaged areas, water jet lancing for cleaning sludge deposits, core boring for obtaining sludge deposits, and scrubbing of internal parts.

  14. Optoelectronic Apparatus Measures Glucose Noninvasively

    NASA Technical Reports Server (NTRS)

    Ansari, Rafat R.; Rovati, Luigi L.

    2003-01-01

    An optoelectronic apparatus has been invented as a noninvasive means of measuring the concentration of glucose in the human body. The apparatus performs polarimetric and interferometric measurements of the human eye to acquire data from which the concentration of glucose in the aqueous humor can be computed. Because of the importance of the concentration of glucose in human health, there could be a large potential market for instruments based on this apparatus.

  15. Laser beam generating apparatus

    DOEpatents

    Warner, Bruce E.; Duncan, David B.

    1993-01-01

    Laser beam generating apparatus including a septum segment disposed longitudinally within the tubular structure of the apparatus. The septum provides for radiatively dissipating heat buildup within the tubular structure and for generating relatively uniform laser beam pulses so as to minimize or eliminate radial pulse delays (the chevron effect).

  16. Laser beam generating apparatus

    DOEpatents

    Warner, Bruce E.; Duncan, David B.

    1994-01-01

    Laser beam generating apparatus including a septum segment disposed longitudinally within the tubular structure of the apparatus. The septum provides for radiatively dissipating heat buildup within the tubular structure and for generating relatively uniform laser beam pulses so as to minimize or eliminate radial pulse delays (the chevron effect).

  17. Spin coating apparatus

    DOEpatents

    Torczynski, John R.

    2000-01-01

    A spin coating apparatus requires less cleanroom air flow than prior spin coating apparatus to minimize cleanroom contamination. A shaped exhaust duct from the spin coater maintains process quality while requiring reduced cleanroom air flow. The exhaust duct can decrease in cross section as it extends from the wafer, minimizing eddy formation. The exhaust duct can conform to entrainment streamlines to minimize eddy formation and reduce interprocess contamination at minimal cleanroom air flow rates.

  18. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Pneumatic apparatus. 236.590 Section 236.590..., Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.590 Pneumatic apparatus. Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and the...

  19. 21 CFR 868.5830 - Autotransfusion apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Autotransfusion apparatus. 868.5830 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5830 Autotransfusion apparatus. (a) Identification. An autotransfusion apparatus is a device used to collect and reinfuse the blood lost by a patient...

  20. 21 CFR 868.5830 - Autotransfusion apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Autotransfusion apparatus. 868.5830 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5830 Autotransfusion apparatus. (a) Identification. An autotransfusion apparatus is a device used to collect and reinfuse the blood lost by a patient...

  1. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Pneumatic apparatus. 236.590 Section 236.590..., Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.590 Pneumatic apparatus. Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and the...

  2. CASTING METHOD AND APPARATUS

    DOEpatents

    Gray, C.F.; Thompson, R.H.

    1958-10-01

    An improved apparatus for the melting and casting of uranium is described. A vacuum chamber is positioned over the casting mold and connected thereto, and a rod to pierce the oxide skin of the molten uranium is fitted into the bottom of the melting chamber. The entire apparatus is surrounded by a jacket, and operations are conducted under a vacuum. The improvement in this apparatus lies in the fact that the top of the melting chamber is fitted with a plunger which allows squeezing of the oxide skin to force out any molten uranium remaining after the skin has been broken and the molten charge has been cast.

  3. Laser beam generating apparatus

    DOEpatents

    Warner, B.E.; Duncan, D.B.

    1993-12-28

    Laser beam generating apparatus including a septum segment disposed longitudinally within the tubular structure of the apparatus. The septum provides for radiatively dissipating heat buildup within the tubular structure and for generating relatively uniform laser beam pulses so as to minimize or eliminate radial pulse delays (the chevron effect). 11 figures.

  4. Positioning apparatus

    DOEpatents

    Vogel, M.A.; Alter, P.

    1983-07-07

    An apparatus is provided for precisely adjusting the position of an article relative to a beam emerging from a neutron source disposed in a housing. The apparatus includes a support pivotably mounted on a movable base plate and freely suspended therefrom. The support is gravity biased toward the housing and carries an article holder movable in a first direction longitudinally of the axis of said beam and normally urged into engagement against said housing. Means are provided for moving the base plate in two directions to effect movement of the suspended holder in two mutually perpendicular directions, respectively, normal to the axis of the beam.

  5. Laser beam generating apparatus

    DOEpatents

    Warner, B.E.; Duncan, D.B.

    1994-02-15

    Laser beam generating apparatus including a septum segment disposed longitudinally within the tubular structure of the apparatus is described. The septum provides for radiatively dissipating heat buildup within the tubular structure and for generating relatively uniform laser beam pulses so as to minimize or eliminate radial pulse delays (the chevron effect). 7 figures.

  6. CONTINUOUS TREATMENT APPARATUS

    DOEpatents

    Erickson, E.E.

    1962-05-15

    An apparatus is described for dissolving a nuclear reactor fuel element in strong acid solutlon. The vapors and entrained liquid resulting from the violent reaction of dissolution are led into a reflux condenser which discharges, not directly back into the top of the reaction vessel in the conventional manner, but by a route leading to the bottom of the apparatus, thereby utilizing the energy of the reaction to bring about a circulation of the solution. (AEC)

  7. Electrochemical apparatus comprising modified disposable rectangular cuvette

    DOEpatents

    Dattelbaum, Andrew M; Gupta, Gautam; Morris, David E

    2013-09-10

    Electrochemical apparatus includes a disposable rectangular cuvette modified with at least one hole through a side and/or the bottom. Apparatus may include more than one cuvette, which in practice is a disposable rectangular glass or plastic cuvette modified by drilling the hole(s) through. The apparatus include two plates and some means of fastening one plate to the other. The apparatus may be interfaced with a fiber optic or microscope objective, and a spectrometer for spectroscopic studies. The apparatus are suitable for a variety of electrochemical experiments, including surface electrochemistry, bulk electrolysis, and flow cell experiments.

  8. Radioactive waste material melter apparatus

    DOEpatents

    Newman, D.F.; Ross, W.A.

    1990-04-24

    An apparatus for preparing metallic radioactive waste material for storage is disclosed. The radioactive waste material is placed in a radiation shielded enclosure. The waste material is then melted with a plasma torch and cast into a plurality of successive horizontal layers in a mold to form a radioactive ingot in the shape of a spent nuclear fuel rod storage canister. The apparatus comprises a radiation shielded enclosure having an opening adapted for receiving a conventional transfer cask within which radioactive waste material is transferred to the apparatus. A plasma torch is mounted within the enclosure. A mold is also received within the enclosure for receiving the melted waste material and cooling it to form an ingot. The enclosure is preferably constructed in at least two parts to enable easy transport of the apparatus from one nuclear site to another. 8 figs.

  9. Radioactive waste material melter apparatus

    DOEpatents

    Newman, Darrell F.; Ross, Wayne A.

    1990-01-01

    An apparatus for preparing metallic radioactive waste material for storage is disclosed. The radioactive waste material is placed in a radiation shielded enclosure. The waste material is then melted with a plasma torch and cast into a plurality of successive horizontal layers in a mold to form a radioactive ingot in the shape of a spent nuclear fuel rod storage canister. The apparatus comprises a radiation shielded enclosure having an opening adapted for receiving a conventional transfer cask within which radioactive waste material is transferred to the apparatus. A plasma torch is mounted within the enclosure. A mold is also received within the enclosure for receiving the melted waste material and cooling it to form an ingot. The enclosure is preferably constructed in at least two parts to enable easy transport of the apparatus from one nuclear site to another.

  10. 29 CFR 1910.219 - Mechanical power-transmission apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 5 2011-07-01 2011-07-01 false Mechanical power-transmission apparatus. 1910.219 Section... Mechanical power-transmission apparatus. (a) General requirements. (1) This section covers all types and... apparatus located in basements. All mechanical power transmission apparatus located in basements, towers...

  11. 29 CFR 1910.219 - Mechanical power-transmission apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 5 2010-07-01 2010-07-01 false Mechanical power-transmission apparatus. 1910.219 Section... Mechanical power-transmission apparatus. (a) General requirements. (1) This section covers all types and... apparatus located in basements. All mechanical power transmission apparatus located in basements, towers...

  12. System, Apparatus, and Method for Active Debris Removal

    NASA Technical Reports Server (NTRS)

    Hickey, Christopher J. (Inventor); Spehar, Peter T. (Inventor); Griffith, Sr., Anthony D. (Inventor); Kohli, Rajiv (Inventor); Burns, Susan H. (Inventor); Gruber, David J. (Inventor); Lee, David E. (Inventor); Robinson, Travis M. (Inventor); Damico, Stephen J. (Inventor); Smith, Jason T. (Inventor)

    2017-01-01

    Systems, apparatuses, and methods for removal of orbital debris are provided. In one embodiment, an apparatus includes a spacecraft control unit configured to guide and navigate the apparatus to a target. The apparatus also includes a dynamic object characterization unit configured to characterize movement, and a capture feature, of the target. The apparatus further includes a capture and release unit configured to capture a target and deorbit or release the target. The collection of these apparatuses is then employed as multiple, independent and individually operated vehicles launched from a single launch vehicle for the purpose of disposing of multiple debris objects.

  13. Apparatus for measuring particle properties

    DOEpatents

    Rader, D.J.; Castaneda, J.N.; Grasser, T.W.; Brockmann, J.E.

    1998-08-11

    An apparatus is described for determining particle properties from detected light scattered by the particles. The apparatus uses a light beam with novel intensity characteristics to discriminate between particles that pass through the beam and those that pass through an edge of the beam. The apparatus can also discriminate between light scattered by one particle and light scattered by multiple particles. The particle`s size can be determined from the intensity of the light scattered. The particle`s velocity can be determined from the elapsed time between various intensities of the light scattered. 11 figs.

  14. Site survey method and apparatus

    DOEpatents

    Oldham, James G.; Spencer, Charles R.; Begley, Carl L.; Meyer, H. Robert

    1991-06-18

    The disclosure of the invention is directed to a site survey ground vehicle based apparatus and method for automatically detecting source materials, such as radioactivity, marking the location of the source materials, such as with paint, and mapping the location of the source materials on a site. The apparatus of the invention is also useful for collecting and analyzing samples. The apparatus includes a ground vehicle, detectors mounted at the front of the ground vehicle, and individual detector supports which follow somewhat irregular terrain to allow consistent and accurate detection, and autolocation equipment.

  15. Site survey method and apparatus

    DOEpatents

    Oldham, J.G.; Spencer, C.R.; Begley, C.L.; Meyer, H.R.

    1991-06-18

    The disclosure of the invention is directed to a site survey ground vehicle based apparatus and method for automatically detecting source materials, such as radioactivity, marking the location of the source materials, such as with paint, and mapping the location of the source materials on a site. The apparatus of the invention is also useful for collecting and analyzing samples. The apparatus includes a ground vehicle, detectors mounted at the front of the ground vehicle, and individual detector supports which follow somewhat irregular terrain to allow consistent and accurate detection, and autolocation equipment. 19 figures.

  16. Apparatus for measuring particle properties

    DOEpatents

    Rader, Daniel J.; Castaneda, Jaime N.; Grasser, Thomas W.; Brockmann, John E.

    1998-01-01

    An apparatus for determining particle properties from detected light scattered by the particles. The apparatus uses a light beam with novel intensity characteristics to discriminate between particles that pass through the beam and those that pass through an edge of the beam. The apparatus can also discriminate between light scattered by one particle and light scattered by multiple particles. The particle's size can be determined from the intensity of the light scattered. The particle's velocity can be determined from the elapsed time between various intensities of the light scattered.

  17. Beam connector apparatus and assembly

    NASA Technical Reports Server (NTRS)

    Vontiesenhausen, G. F. (Inventor)

    1983-01-01

    An apparatus and assembly for connecting beams and like structural members is disclosed which is particularly advantageous for connecting two members which are moved laterally into place. The connector apparatus requires no relative longitudinal movement between the ends of the beams or members being connected to make a connection joint. The apparatus includes a receptacle member and a connector housing carried by opposed ends of the structural member being connected. A spring-loaded connector member is carried by the connector housing which may be released for extension and engagement into the receptacle member.

  18. Visual examination apparatus

    NASA Technical Reports Server (NTRS)

    Haines, R. F.; Fitzgerald, J. W.; Rositano, S. A. (Inventor)

    1973-01-01

    An automated visual examination apparatus for measuring visual sensitivity and mapping blind spot location is described. The apparatus includes a projection system for displaying to a patient a series of visual stimuli, a response switch enabling him to indicate his reaction to the stimuli, and a recording system responsive to both the visual stimuli per se and the patient's response. The recording system provides a correlated permanent record of both stimuli and response from which a substantive and readily apparent visual evaluation can be made.

  19. An Inexpensive, Foolproof Apparatus for Flash Chromatography.

    ERIC Educational Resources Information Center

    Thompson, Wayne J.; Hanson, Bryan A.

    1984-01-01

    Describes a new, modified "flash chromatography" apparatus which overcomes difficulties found in conventional apparatus. For example, an expensive teflon pressure valve is not necessary in the modified version. The apparatus is suitable as an instructional tool in undergraduate courses. (JN)

  20. Apparatus Named After Our Academic Ancestors — I

    NASA Astrophysics Data System (ADS)

    Greenslade, Thomas B.

    2010-12-01

    Let us now praise famous physicists, and the apparatus named after them, with apologies to the writer of Ecclesiastes. I once compiled a list of about 300 pieces of apparatus known to us as X's Apparatus. Some of the values of X are familiar, like Wheatstone and Kelvin and Faraday, but have you heard of Pickering or Rhumkorff or Barlow? In an earlier article about Packard's apparatus,1 I paid homage to an early-20th-century high school teacher, and other articles have mentioned apparatus by a number of other physicists and physics teachers.2 In many cases the apparatus came directly out of research being done by the physicist, or from the need to show the phenomena of physics in the classroom and lecture hall. Here are more stories about apparatus and their makers, starting with three pieces of apparatus that are related to the development of electron physics in the latter half of the 19th century.

  1. Hydrocarbonaceous material processing methods and apparatus

    DOEpatents

    Brecher, Lee E [Laramie, WY

    2011-07-12

    Methods and apparatus are disclosed for possibly producing pipeline-ready heavy oil from substantially non-pumpable oil feeds. The methods and apparatus may be designed to produce such pipeline-ready heavy oils in the production field. Such methods and apparatus may involve thermal soaking of liquid hydrocarbonaceous inputs in thermal environments (2) to generate, though chemical reaction, an increased distillate amount as compared with conventional boiling technologies.

  2. System and Apparatus for Filtering Particles

    NASA Technical Reports Server (NTRS)

    Agui, Juan H. (Inventor); Vijayakumar, Rajagopal (Inventor)

    2015-01-01

    A modular pre-filtration apparatus may be beneficial to extend the life of a filter. The apparatus may include an impactor that can collect a first set of particles in the air, and a scroll filter that can collect a second set of particles in the air. A filter may follow the pre-filtration apparatus, thus causing the life of the filter to be increased.

  3. 16 CFR 1610.5 - Test apparatus and materials.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Test apparatus and materials. 1610.5 Section... STANDARD FOR THE FLAMMABILITY OF CLOTHING TEXTILES The Standard § 1610.5 Test apparatus and materials. (a) Flammability apparatus. The flammability test apparatus consists of a draft-proof ventilated chamber enclosing...

  4. 16 CFR 1610.5 - Test apparatus and materials.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Test apparatus and materials. 1610.5 Section... STANDARD FOR THE FLAMMABILITY OF CLOTHING TEXTILES The Standard § 1610.5 Test apparatus and materials. (a) Flammability apparatus. The flammability test apparatus consists of a draft-proof ventilated chamber enclosing...

  5. 27 CFR 29.53 - Identification of distilling apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... distilling apparatus. 29.53 Section 29.53 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND... Identification of distilling apparatus. (a) General. Each still or condenser manufactured will be identified by... serial number for the apparatus. (b) Marking requirements. The apparatus will be identified in a legible...

  6. 27 CFR 29.53 - Identification of distilling apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... distilling apparatus. 29.53 Section 29.53 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND... Identification of distilling apparatus. (a) General. Each still or condenser manufactured will be identified by... serial number for the apparatus. (b) Marking requirements. The apparatus will be identified in a legible...

  7. 47 CFR 32.6311 - Station apparatus expense.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Station apparatus expense. 32.6311 Section 32... apparatus expense. This account shall include expenses associated with station apparatus. Expenses associated with company internal use communication equipment shall be recorded in Account 6123, Office...

  8. 47 CFR 32.6311 - Station apparatus expense.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 2 2011-10-01 2011-10-01 false Station apparatus expense. 32.6311 Section 32... apparatus expense. This account shall include expenses associated with station apparatus. Expenses associated with company internal use communication equipment shall be recorded in Account 6123, Office...

  9. Lacrimal secretory IgA in active posterior uveitis induced by Toxoplasma gondii.

    PubMed

    Lynch, Maria Isabel; Cordeiro, Francisco; Ferreira, Silvana; Ximenes, Ricardo; Oréfice, Fernando; Malagueño, Elizabeth

    2004-12-01

    It is quite difficult to diagnose active toxoplasmosis in patients with ocular toxoplasmosis. Active posterior uveitis presumably due to Toxoplasma gondii infection (APUPT) is seldom produced during a prime-infection; hence most patients do not show high IgM antibodies. High levels of IgA have been described in active toxoplasmosis. The purpose of this study was to investigate possible association between APUPT and the specific anti-parasite sIgA in tears. The study was carried out as case-control. Tears of 25 clinically confirmed APUPT patients and 50 healthy control subjects were analyzed. All were IgG seropositive. Specific sIgA was determined by ELISA assay using T. gondii RH strain crude extract. Anti-T. gondii sIgA was found in 84% of the cases and in 22% of the control subjects. The intensity of the reaction was higher in APUPT cases (P = 0.007). There was strong association between APUPT patients and lacrimal sIgA (odds-ratio 18.61, P = 0.0001). ELISA test sensitivity was 84% and specificity 78%. Our data suggest that anti-T.gondii secretory IgA found in tears may become an important marker for active ocular toxoplasmosis.

  10. Micromachine friction test apparatus

    DOEpatents

    deBoer, Maarten P.; Redmond, James M.; Michalske, Terry A.

    2002-01-01

    A microelectromechanical (MEM) friction test apparatus is disclosed for determining static or dynamic friction in MEM devices. The friction test apparatus, formed by surface micromachining, is based on a friction pad supported at one end of a cantilevered beam, with the friction pad overlying a contact pad formed on the substrate. A first electrostatic actuator can be used to bring a lower surface of the friction pad into contact with an upper surface of the contact pad with a controlled and adjustable force of contact. A second electrostatic actuator can then be used to bend the cantilevered beam, thereby shortening its length and generating a relative motion between the two contacting surfaces. The displacement of the cantilevered beam can be measured optically and used to determine the static or dynamic friction, including frictional losses and the coefficient of friction between the surfaces. The test apparatus can also be used to assess the reliability of rubbing surfaces in MEM devices by producing and measuring wear of those surfaces. Finally, the friction test apparatus, which is small in size, can be used as an in situ process quality tool for improving the fabrication of MEM devices.

  11. Neutron detection apparatus and method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Derzon, Mark S.; Borek, III, Theodore T.

    An apparatus for neutron detection is provided. The apparatus comprises a sensor medium in electrical contact with an electrode arrangement conformed to collect radiation-generated charge from the sensor medium. The sensor medium comprises a borazine and/or a borazine-based polymer.

  12. Current measurement apparatus

    DOEpatents

    Umans, Stephen D.

    2008-11-11

    Apparatus and methods are provided for a system for measurement of a current in a conductor such that the conductor current may be momentarily directed to a current measurement element in order to maintain proper current without significantly increasing an amount of power dissipation attributable to the current measurement element or adding resistance to assist in current measurement. The apparatus and methods described herein are useful in superconducting circuits where it is necessary to monitor current carried by the superconducting elements while minimizing the effects of power dissipation attributable to the current measurement element.

  13. Radioactive waste processing apparatus

    DOEpatents

    Nelson, R.E.; Ziegler, A.A.; Serino, D.F.; Basnar, P.J.

    1985-08-30

    Apparatus for use in processing radioactive waste materials for shipment and storage in solid form in a container is disclosed. The container includes a top, and an opening in the top which is smaller than the outer circumference of the container. The apparatus includes an enclosure into which the container is placed, solution feed apparatus for adding a solution containing radioactive waste materials into the container through the container opening, and at least one rotatable blade for blending the solution with a fixing agent such as cement or the like as the solution is added into the container. The blade is constructed so that it can pass through the opening in the top of the container. The rotational axis of the blade is displaced from the center of the blade so that after the blade passes through the opening, the blade and container can be adjusted so that one edge of the blade is adjacent the cylindrical wall of the container, to insure thorough mixing. When the blade is inside the container, a substantially sealed chamber is formed to contain vapors created by the chemical action of the waste solution and fixant, and vapors emanating through the opening in the container. The chamber may be formed by placing a removable extension over the top of the container. The extension communicates with the apparatus so that such vapors are contained within the container, extension and solution feed apparatus. A portion of the chamber includes coolant which condenses the vapors. The resulting condensate is returned to the container by the force of gravity.

  14. Space processing experimental apparatus - A survey

    NASA Technical Reports Server (NTRS)

    Siebel, M. P.

    1977-01-01

    The processing of materials in a low-g environment was started approximately 10 years ago. This article surveys the apparatus developed during that period. A low-g environment occurs naturally in a free-flying spacecraft (e.g., in manned flights such as Apollo, Skylab, and ASTP); low-g conditions also occur in other free-falling bodies such as sounding rockets and drop tower capsules. Apparatus has been developed for all these craft. Most of the apparatus described serves to melt and resolidify materials in low g; the material may be contained or, by virtue of the environment, freely floating. Other apparatus for separation of intimately mixed components or species is also described. A general conclusion is drawn that the apparatus addresses only a few of the possibilities available, is still at the experimental stage, and is of laboratory scale. It is predicted that processes showing promise will be scaled up to derive economic advantages in the Shuttle era of space flight.

  15. 21 CFR 868.5165 - Nitric oxide administration apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nitric oxide administration apparatus. 868.5165... apparatus. (a) Identification. The nitric oxide administration apparatus is a device used to add nitric oxide to gases that are to be breathed by a patient. The nitric oxide administration apparatus is to be...

  16. 21 CFR 884.5900 - Therapeutic vaginal douche apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Therapeutic vaginal douche apparatus. 884.5900... Devices § 884.5900 Therapeutic vaginal douche apparatus. (a) Identification. A therapeutic vaginal douche apparatus is a device that is a bag or bottle with tubing and a nozzle. The apparatus does not include...

  17. 21 CFR 884.5900 - Therapeutic vaginal douche apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Therapeutic vaginal douche apparatus. 884.5900... Devices § 884.5900 Therapeutic vaginal douche apparatus. (a) Identification. A therapeutic vaginal douche apparatus is a device that is a bag or bottle with tubing and a nozzle. The apparatus does not include...

  18. 21 CFR 868.5165 - Nitric oxide administration apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nitric oxide administration apparatus. 868.5165... apparatus. (a) Identification. The nitric oxide administration apparatus is a device used to add nitric oxide to gases that are to be breathed by a patient. The nitric oxide administration apparatus is to be...

  19. An Apparatus for Photochemical Studies.

    ERIC Educational Resources Information Center

    Winter, M. J.; Winter, P. V.

    1984-01-01

    Describes an apparatus developed for photochemical studies, particularly those involving the fluorescence of halogenated acetones. The apparatus is constructed from equipment normally found in a moderately sized physical chemical laboratory. Also provides background information on some aspects of the photophysics of halogenated propanones. (JN)

  20. EXTRACTION APPARATUS

    DOEpatents

    Ballard, A.E.; Brigham, H.R.

    1958-10-28

    An apparatus whereby relatlvely volatile solvents may be contacted with volatile or non-volatile material without certaln attendant hazards is described. A suitable apparatus for handling relatively volatlle liqulds may be constructed comprising a tank, and a closure covering the tank and adapted to be securely attached to an external suppont. The closure is provided with a rigidly mounted motor-driven agitator. This agitator is connected from the driving motor lnto the lnterlor of the tank through a gland adapted to be cooled witb inert gas thereby eliminating possible hazard due to frictional heat. The closure is arranged so that the tank may be removed from it without materially dlsturbing the closure which, as described, carrles the motor driven agitator and other parts.

  1. Microelectromechanical safing and arming apparatus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koehler, David R; Hoke, Darren A; Weichman, Louis S

    2006-05-30

    A two-stage acceleration sensing apparatus is disclosed which has applications for use in a fuze assembly for a projected munition. The apparatus, which can be formed by bulk micromachining or LIGA, can sense acceleration components along two orthogonal directions to enable movement of a shuttle from an "as-fabricated" position to a final position and locking of the shuttle in the final position. With the shuttle moved to the final position, the apparatus can perform one or more functions including completing an explosive train or an electrical switch closure, or allowing a light beam to be transmitted through the device.

  2. Microelectromechanical safing and arming apparatus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koehler, David R; Hoke, Darren A; Weichman, Louis S

    2008-06-10

    A two-stage acceleration sensing apparatus is disclosed which has applications for use in a fuze assembly for a projected munition. The apparatus, which can be formed by bulk micromachining or LIGA, can sense acceleration components along two orthogonal directions to enable movement of a shuttle from an "as-fabricated" position to a final position and locking of the shuttle in the final position. With the shuttle moved to the final position, the apparatus can perform one or more functions including completing an explosive train or an electrical switch closure, or allowing a light beam to be transmitted through the device.

  3. Hot cell shield plug extraction apparatus

    DOEpatents

    Knapp, Philip A.; Manhart, Larry K.

    1995-01-01

    An apparatus is provided for moving shielding plugs into and out of holes in concrete shielding walls in hot cells for handling radioactive materials without the use of external moving equipment. The apparatus provides a means whereby a shield plug is extracted from its hole and then swung approximately 90 degrees out of the way so that the hole may be accessed. The apparatus uses hinges to slide the plug in and out and to rotate it out of the way, the hinge apparatus also supporting the weight of the plug in all positions, with the load of the plug being transferred to a vertical wall by means of a bolting arrangement.

  4. Biological particle identification apparatus

    DOEpatents

    Salzman, Gary C.; Gregg, Charles T.; Grace, W. Kevin; Hiebert, Richard D.

    1989-01-01

    An apparatus and method for making multiparameter light scattering measurements from suspensions of biological particles is described. Fourteen of the sixteen Mueller matrix elements describing the particles under investigation can be substantially individually determined as a function of scattering angle and probing radiations wavelength, eight elements simultaneously for each of two apparatus configurations using an apparatus which incluees, in its simplest form, two polarization modulators each operating at a chosen frequency, one polarizer, a source of monochromatic electromagnetic radiation, a detector sensitive to the wavelength of radiation employed, eight phase-sensitive detectors, and appropriate electronics. A database of known biological particle suspensions can be assembled, and unknown samples can be quickly identified once measurements are performed on it according to the teachings of the subject invention, and a comparison is made with the database.

  5. Apparatus for ultrasonic nebulization

    DOEpatents

    Olson, Kenneth W.; Haas, Jr., William J.; Fassel, Velmer A.

    1978-08-29

    An improved apparatus for ultrasonic nebulization of liquid samples or suspensions in which the piezoelectric transducer is protected from chemical attack and erosion. The transducer is protected by being bonded to the inner surface of a glass plate which forms one end wall of a first hollow body provided with apparatus for circulating a fluid for cooling and stabilizing the transducer. The glass plate, which is one-half wavelength in thickness to provide an acoustically coupled outer nebulizing surface, seals an opening in a second hollow body which encloses an aerosol mixing chamber. The second body includes apparatus for delivering the sample solution to the nebulizing surface, a gas inlet for providing a flow of carrier gas for transporting the aerosol of the nebulized sample and an aerosol outlet.

  6. 46 CFR 164.009-11 - Furnace apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Furnace apparatus. 164.009-11 Section 164.009-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS... apparatus. (a) The test furnace apparatus consists of a furnace tube, stabilizer, draft shield, furnace...

  7. 46 CFR 164.009-11 - Furnace apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Furnace apparatus. 164.009-11 Section 164.009-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS... apparatus. (a) The test furnace apparatus consists of a furnace tube, stabilizer, draft shield, furnace...

  8. Reactor apparatus

    DOEpatents

    Echtler, J. Paul

    1981-01-01

    A reactor apparatus for hydrocracking a polynuclear aromatic hydrocarbonaceous feedstock to produce lighter hydrocarbon fuels by contacting the hydrocarbonaceous feedstock with hydrogen in the presence of a molten metal halide catalyst.

  9. Universal penetration test apparatus with fluid penetration sensor

    DOEpatents

    Johnson, Phillip W.; Stampfer, Joseph F.; Bradley, Orvil D.

    1999-01-01

    A universal penetration test apparatus for measuring resistance of a material to a challenge fluid. The apparatus includes a pad saturated with the challenge fluid. The apparatus includes a compression assembly for compressing the material between the pad and a compression member. The apparatus also includes a sensor mechanism for automatically detecting when the challenge fluid penetrates the material.

  10. 21 CFR 868.5430 - Gas-scavenging apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gas-scavenging apparatus. 868.5430 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5430 Gas-scavenging apparatus. (a) Identification. A gas-scavenging apparatus is a device intended to collect excess anesthetic, analgesic, or trace...

  11. 21 CFR 868.5430 - Gas-scavenging apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Gas-scavenging apparatus. 868.5430 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5430 Gas-scavenging apparatus. (a) Identification. A gas-scavenging apparatus is a device intended to collect excess anesthetic, analgesic, or trace...

  12. Infrared microscope inspection apparatus

    DOEpatents

    Forman, S.E.; Caunt, J.W.

    1985-02-26

    Apparatus and system for inspecting infrared transparents, such as an array of photovoltaic modules containing silicon solar cells, includes an infrared microscope, at least three sources of infrared light placed around and having their axes intersect the center of the object field and means for sending the reflected light through the microscope. The apparatus is adapted to be mounted on an X-Y translator positioned adjacent the object surface. 4 figs.

  13. Infrared microscope inspection apparatus

    DOEpatents

    Forman, Steven E.; Caunt, James W.

    1985-02-26

    Apparatus and system for inspecting infrared transparents, such as an array of photovoltaic modules containing silicon solar cells, includes an infrared microscope, at least three sources of infrared light placed around and having their axes intersect the center of the object field and means for sending the reflected light through the microscope. The apparatus is adapted to be mounted on an X-Y translator positioned adjacent the object surface.

  14. 49 CFR 234.227 - Train detection apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Train detection apparatus. 234.227 Section 234.227..., Inspection, and Testing Maintenance Standards § 234.227 Train detection apparatus. (a) Train detection apparatus shall be maintained to detect a train or railcar in any part of a train detection circuit, in...

  15. 30 CFR 7.406 - Flame test apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Flame test apparatus. 7.406 Section 7.406 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND... Cable Splice Kits § 7.406 Flame test apparatus. The principal parts of the apparatus used to test for...

  16. 49 CFR 234.227 - Train detection apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Train detection apparatus. 234.227 Section 234.227..., Inspection, and Testing Maintenance Standards § 234.227 Train detection apparatus. (a) Train detection apparatus shall be maintained to detect a train or railcar in any part of a train detection circuit, in...

  17. 30 CFR 7.406 - Flame test apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Flame test apparatus. 7.406 Section 7.406 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND... Cable Splice Kits § 7.406 Flame test apparatus. The principal parts of the apparatus used to test for...

  18. 30 CFR 7.26 - Flame test apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Flame test apparatus. 7.26 Section 7.26 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF... test apparatus. The principal parts of the apparatus used to test for flame-resistance of brattice...

  19. 30 CFR 7.26 - Flame test apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Flame test apparatus. 7.26 Section 7.26 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF... test apparatus. The principal parts of the apparatus used to test for flame-resistance of brattice...

  20. Universal penetration test apparatus with fluid penetration sensor

    DOEpatents

    Johnson, P.W.; Stampfer, J.F.; Bradley, O.D.

    1999-02-02

    A universal penetration test apparatus is described for measuring resistance of a material to a challenge fluid. The apparatus includes a pad saturated with the challenge fluid. The apparatus includes a compression assembly for compressing the material between the pad and a compression member. The apparatus also includes a sensor mechanism for automatically detecting when the challenge fluid penetrates the material. 23 figs.

  1. Conjunctivitis and Total IgE in Lacrimal Fluid: Lacrytest Screening

    PubMed Central

    Monzón, Susana; Arrondo, Elena; Bartra, Joan; Torres, Ferran; Basagaña, María; San Miguel, M. del Mar; Alonso, Rosario; Cisteró-Bahima, Anna

    2009-01-01

    Total tear IgE has been considered to play an important role in allergic conjunctivitis, and measurement has been considered useful for diagnosis. The aim of this study was to ascertain whether Lacrytest®, a new commercialised method to detect IgE levels in lacrimal fluid, could constitute a screening test for the diagnosis of allergic conjunctivitis. This was a cross-sectional study. Patients with seasonal and perennial allergic conjunctivitis, vernal keratoconjunctivitis and a control group were included. Clinical history, ophthalmic examination, skin prick test and conjunctival provocation test were obtained. Lacrytest® was later performed in all groups. Fifty-four patients were enrolled: thirty with IgE-mediated conjunctivitis and, nine with vernal keratoconjunctivitis and fifteen controls. Lacrytest® was negative in all controls, positive in 20% of the IgE-mediated conjunctivitis group and in 88.9% of the vernal keratoconjunctivitis group. Global statistically-significant differences were found among the three groups (P = .003). Sensitivity of the test in the IgE-mediated conjunctivitis group was 20%, specificity 100%, positive predictive value 100%, and negative predictive value 38.46%, while in VKC sensitivity was 88.88%, specificity 100%, positive predictive value 100%, and negative predictive value 93.75%. Our data confirm that this test is not useful for screening allergic conjunctivitis. Lacrytest®, while not providing any useful information to an allergist, could be helpful for ophthalmologists to confirm an IgE-mediated or VKC conjunctivitis. PMID:20975798

  2. An apparatus for preparing benthic samples aboard ship

    USGS Publications Warehouse

    Pepper, Phillip N.; Girard, Thomas L.; Stapanian, Martin A.

    2001-01-01

    We describe a safe and effective apparatus for washing and reducing the volume of benthic samples collected by grab samplers aboard ship. The sample is transferred directly from the dredge to the apparatus and then washed with water pumped through pipes in the apparatus and from onboard hoses. Wastewater and materials smaller than 0.541 mm in diameter are washed overboard. Larger materials, including benthic organisms, collect on an upper 0.64-cm screen and on a lower 30-mm-mesh stainless steel bolt cloth. A collection jar is screwed into the bottom of the apparatus. Therefore, transfer of sample material from the apparatus to the jar is quick and easy. This apparatus has several advantages for use aboard ship over others described in the literature, especially in rough seas, in cold weather, and at night. The apparatus provides a safe and convenient platform for washing and reducing samples, and samples can be prepared while the vessel is traveling at full speed.

  3. Fiber pulling apparatus modification

    NASA Technical Reports Server (NTRS)

    Smith, Guy A.; Workman, Gary L.

    1992-01-01

    A reduced gravity fiber pulling apparatus (FPA) was constructed in order to study the effects of gravity on glass fiber formation. The apparatus was specifically designed and built for use on NASA's KC-135 aircraft. Four flights have been completed to date during which E-glass fiber was successfully produced in simulated zero, high, and lunar gravity environments. In addition simulated lunar soil samples were tested for their fiber producing properties using the FPA.

  4. Apparatus Notes.

    ERIC Educational Resources Information Center

    Eaton, Bruce G., Ed.

    1982-01-01

    Presents a technique to produce samples for x-ray diffraction studies on the Tel-X-Ometer 80 x-ray apparatus from readily available crystalline powders and discusses observations of transverse modes of an optical resonator. (SK)

  5. Methods and apparatus for handling or treating particulate material

    NASA Technical Reports Server (NTRS)

    Littman, Howard (Inventor); Plawsky, Joel L. (Inventor); Paccione, John D. (Inventor)

    2009-01-01

    An improved draft tube spout fluid bed (DTSFB) mixing, handling, conveying, and treating apparatus and systems, and methods for operating are provided. The apparatus and systems can accept particulate material and pneumatically or hydraulically conveying the material to mix and/or treat the material. In addition to conveying apparatus, a collection and separation apparatus adapted to receive the conveyed particulate material is also provided. The collection apparatus may include an impaction plate against which the conveyed material is directed to improve mixing and/or treatment. The improved apparatus are characterized by means of controlling the operation of the pneumatic or hydraulic transfer to enhance the mixing and/or reacting by controlling the flow of fluids, for example, air, into and out of the apparatus. The disclosed apparatus may be used to mix particulate material, for example, mortar; react fluids with particulate material; coat particulate material, or simply convey particulate material.

  6. METHOD AND APPARATUS FOR EARTH PENETRATION

    DOEpatents

    Adams, W.M.

    1963-12-24

    A nuclear reactor apparatus for penetrating into the earth's crust is described. The apparatus comprises a cylindrical nuclear core operating at a temperature that is higher than the melting temperature of rock. A high-density ballast member is coupled to the nuclear core such that the overall density of the core-ballast assembly is greater than the density of molten rock. The nuclear core is thermally insulated so that its heat output is constrained to flow axially, with radial heat flow being minimized. In operation, the apparatus is placed in contact with the earth's crust at the point desired to be penetrated. The heat output of the reactor melts the underlying rock, and the apparatus sinks through the resulting magma. The fuel loading of the reactor core determines the ultimate depth of crust penetration. (AEC)

  7. Multiple Natural and Experimental Inflammatory Rabbit Lacrimal Gland Phenotypes

    PubMed Central

    Mircheff, Austin K.; Wang, Yanru; Schechter, Joel E.; Li, Meng; Tong, Warren; Attar, Mayssa; Chengalvala, Murty; Harmuth, Joe; Prusakiewicz, Jeffery J.

    2016-01-01

    Purpose To investigate lacrimal gland (LG) immunophysiological and immune-mediated inflammatory process (IMIP) phenotype diversity. Methods Ex vivo matured dendritic cells (mDC) were loaded with acinar cell microparticles (MP). Peripheral blood lymphocytes (PBL) were activated in mixed cell reactions with mDC and injected directly into autologous, unilateral LG (1° ATD-LG) of two rabbit cohorts, one naïve, one immunized with a LG lysate membrane fraction (Pi). Autoimmune IgG titers were assayed by ELISA, MCR PBL stimulation indices (SI) by [3H]-thymidine incorporation. Schirmer tests without and with topical anesthetic (STT-I, STT-IA) and rose Bengal (RB) staining tests were performed. H&E and immunohistochemically stained sections were examined. RNA yields and selected transcript abundances were measured. Immune cell number and transcript abundance data were submitted to Principal Component Analysis (PCA). Results Immunizing Pi dose influenced SI but not IgG titers. STT scores were decreased, and rose Bengal scores increased, by day 118 after immunization. Previous immunization exacerbated scores in 1° ATD-eyes and exacerbated 1° ATD-LG atrophy. IMIP were evident in 2° ATD-LG as well as 1° ATD-LG. PCA described diverse immunophysiological phenotypes in control LG and diverse IMIP phenotypes in ATD-LG. IgG titers and SI pre-adoptive transfer were significantly associated with certain post-adoptive transfer IMIP phenotype features, and certain LG IMIP features were significantly associated with RB and STT IA scores. Conclusions The underlying variability of normal states may contribute to the diversity of experimental IMIP phenotypes. The ability to generate and characterize diverse phenotypes may lead to phenotype-specific diagnostic and therapeutic paradigms. PMID:27423911

  8. 42 CFR 84.70 - Self-contained breathing apparatus; description.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Self-contained breathing apparatus; description. 84...-Contained Breathing Apparatus § 84.70 Self-contained breathing apparatus; description. (a) Self-contained breathing apparatus, including all completely assembled, portable, self-contained devices designed for use...

  9. 42 CFR 84.70 - Self-contained breathing apparatus; description.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Self-contained breathing apparatus; description. 84...-Contained Breathing Apparatus § 84.70 Self-contained breathing apparatus; description. (a) Self-contained breathing apparatus, including all completely assembled, portable, self-contained devices designed for use...

  10. Apparatus Notes

    ERIC Educational Resources Information Center

    Eaton, Bruce G., Ed.

    1976-01-01

    Includes five brief articles on: solar-heating demonstration equipment, mercury or sodium vapor lamp spectroscopy, an apparatus for simulating variable stars, a voltage-to-frequency converter, and an introductory absorption experiment for low-energy beta particles. (MLH)

  11. Electric arc saw apparatus

    DOEpatents

    Deichelbohrer, P.R.

    1983-08-08

    A portable, hand-held electric arc saw apparatus comprising a small frame for supporting an electrically conducting rotary blade which serves as an electrode for generating an electric arc between the blade and a workpiece of opposite polarity. Electrically conducting means are provided on said frame for transmitting current to said blade. A pair of freely movable endless belts in the form of crawler treads are employed to facilitate movement of the apparatus relative to the workpiece.

  12. Apparatus for fixing latency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hall, David R; Bartholomew, David B; Moon, Justin

    2009-09-08

    An apparatus for fixing computational latency within a deterministic region on a network comprises a network interface modem, a high priority module and at least one deterministic peripheral device. The network interface modem is in communication with the network. The high priority module is in communication with the network interface modem. The at least one deterministic peripheral device is connected to the high priority module. The high priority module comprises a packet assembler/disassembler, and hardware for performing at least one operation. Also disclosed is an apparatus for executing at least one instruction on a downhole device within a deterministic region,more » the apparatus comprising a control device, a downhole network, and a downhole device. The control device is near the surface of a downhole tool string. The downhole network is integrated into the tool string. The downhole device is in communication with the downhole network.« less

  13. Mass spectrometer having a derivatized sample presentation apparatus

    DOEpatents

    Nelson, Randall W.

    2000-07-25

    A mass spectrometer having a derivatized sample presentation apparatus is provided. The sample presentation apparatus has a complex bound to the surface of the sample presentation apparatus. This complex includes a molecule which may chemically modify a biomolecule.

  14. Apparatus Named after Our Academic Ancestors--I

    ERIC Educational Resources Information Center

    Greenslade, Thomas B., Jr.

    2010-01-01

    Let us now praise famous physicists, and the apparatus named after them, with apologies to the writer of Ecclesiastes. I once compiled a list of about 300 pieces of apparatus known to us as X's Apparatus. Some of the values of X are familiar, like Wheatstone and Kelvin and Faraday, but have you heard of Pickering or Rhumkorff or Barlow? In an…

  15. Ultrasonic drilling apparatus

    DOEpatents

    Duran, Edward L.; Lundin, Ralph L.

    1989-01-01

    Apparatus attachable to an ultrasonic drilling machine for drilling deep holes in very hard materials, such as boron carbide, is provided. The apparatus utilizes a hollow spindle attached to the output horn of the ultrasonic drilling machine. The spindle has a hollow drill bit attached at the opposite end. A housing surrounds the spindle, forming a cavity for holding slurry. In operation, slurry is provided into the housing, and into the spindle through inlets while the spindle is rotating and ultrasonically reciprocating. Slurry flows through the spindle and through the hollow drill bit to cleanse the cutting edge of the bit during a drilling operation.

  16. Ultrasonic drilling apparatus

    DOEpatents

    Duran, E.L.; Lundin, R.L.

    1988-06-20

    Apparatus attachable to an ultrasonic drilling machine for drilling deep holes in very hard materials, such as boron carbide, is provided. The apparatus utilizes a hollow spindle attached to the output horn of the ultrasonic drilling machine. The spindle has a hollow drill bit attached at the opposite end. A housing surrounds the spindle, forming a cavity for holding slurry. In operation, slurry is provided into the housing, and into the spindle through inlets while the spindle is rotating and ultrasonically reciprocating. Slurry flows through the spindle and through the hollow drill bit to cleanse the cutting edge of the bit during a drilling operation. 3 figs.

  17. Analytical liquid test sample filtration apparatus

    DOEpatents

    Lohnes, Brent C.; Turner, Terry D.; Klingler, Kerry M.; Clark, Michael L.

    1996-01-01

    A liquid sample filtration apparatus includes: a) a module retaining filter elements; b) a filter clamping and fluid injection apparatus positioned relative to the module to engage a filter element thereon, and includes a pair of first and second opposing engageable members to sealing engage a filter element therebetween; c) an inlet tube connected to an opposing engageable member; d) an outlet tube connected to an opposing engageable member; e) a motor to move the module relative to the filter clamping and injection apparatus to register filter elements on the module to the clamping and injection apparatus; and f) a motor associated with the filter clamping and injection apparatus to move the opposing engageable members into substantial sealing fluid communication relative to a filter element on the module. An apparatus for engaging opposing ends of a filter element includes: a) a member having a recess configured to engage one end of a filter element, including a first fluid passage communicating with the recess to pass fluid between the recess and externally of the member; and b) a second member positioned in opposing juxtaposition relative to the other member, and having a projection sized and shaped to matingly fit within the other member recess, the second member projection including a second recess configured to engage the other end of the filter element, the second member including a second fluid passage communicating with the second recess to pass fluid between the second recess and externally of the second member.

  18. 46 CFR 78.47-27 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Markings for Fire and Emergency Equipment, Etc. § 78.47-27 Self-contained breathing apparatus. Lockers or spaces containing self-contained breathing apparatus shall be marked “SELF-CONTAINED BREATHING APPARATUS... 46 Shipping 3 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 78.47-27 Section 78...

  19. 46 CFR 78.47-27 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Markings for Fire and Emergency Equipment, Etc. § 78.47-27 Self-contained breathing apparatus. Lockers or spaces containing self-contained breathing apparatus shall be marked “SELF-CONTAINED BREATHING APPARATUS... 46 Shipping 3 2011-10-01 2011-10-01 false Self-contained breathing apparatus. 78.47-27 Section 78...

  20. Data acquisition channel apparatus

    NASA Astrophysics Data System (ADS)

    Higgins, C. H.; Skipper, J. D.

    1985-10-01

    Dicussed is a hybrid integrated circuit data acquisition channel apparatus employing an operational amplifier fed by a low current differential bipolar transistor preamplifier having separate feedback gain and signal gain determining elements and providing an amplified signal output to a sample and hold and analog-to-digital converter circuits. The disclosed apparatus operates with low energy and small space requirements and is capable of operations without the sample and hold circuit where the nature of the applied input signal permits.

  1. Tissue culture apparatus for flight experimentation

    NASA Technical Reports Server (NTRS)

    Scheld, H. W.; Magnuson, J. W.; Krikorian, A. D.

    1985-01-01

    The development of an apparatus for in-flight treatment of cells, tissues, or small organisms for microscopic and chemical analyses is discussed. The hardware for the apparatus is to have: (1) automated functions, (2) the capability to interface with ground-based facilities, (3) independently controlled chambers, (4) variable chamber configurations and volumes, and (4) the capabilities for processing the materials. The components of the equipment used on Skylab 3 for the study of animal cells are described. The design of an apparatus which incorporates all the required capabilities is proposed.

  2. Apparatus and method for measuring viscosity

    DOEpatents

    Murphy, R.J. Jr.

    1986-02-25

    The present invention is directed to an apparatus and method for measuring the viscosity of a fluid. This apparatus and method is particularly useful for the measurement of the viscosity of a liquid in a harsh environment characterized by high temperature and the presence of corrosive or deleterious gases and vapors which adversely affect conventional ball or roller bearings. The apparatus and method of the present invention employ one or more flexural or torsional bearings to suspend a bob capable of limited angular motion within a rotatable sleeve suspended from a stationary frame. 7 figs.

  3. Apparatus and method for measuring viscosity

    DOEpatents

    Murphy, Jr., Robert J.

    1986-01-01

    The present invention is directed to an apparatus and method for measuring the viscosity of a fluid. This apparatus and method is particularly useful for the measurement of the viscosity of a liquid in a harsh environment characterized by high temperature and the presence of corrosive or deleterious gases and vapors which adversely affect conventional ball or roller bearings. The apparatus and method of the present invention employ one or more flexural or torsional bearings to suspend a bob capable of limited angular motion within a rotatable sleeve suspended from a stationary frame.

  4. APPARATUS FOR PRODUCING AND MANIPULATING PLASMAS

    DOEpatents

    Colgate, S.A.; Ferguson, J.P.; Furth, H.P.; Wright, R.E.

    1960-07-26

    An electrical pinch discharge apparatus is described for producing and manipulating high-temperature plasmas. The apparatus may be of either the linear or toroidal pinch discharge type. Arrangements are provided whereby stabilizing fields may be trapped in the plasma external to the main pinch discharge path and the boundary condition of the stabilizing field programed so as to stabilize the discharge or to promote instabilities in the discharge as desired. The produced plasmas may be employed for various purposes, and fusion neutrons have been produced with the apparatus.

  5. Coupling apparatus for a metal vapor laser

    DOEpatents

    Ball, D.G.; Miller, J.L.

    1993-02-23

    Coupling apparatus for a large bore metal vapor laser is disclosed. The coupling apparatus provides for coupling high voltage pulses (approximately 40 KV) to a metal vapor laser with a high repetition rate (approximately 5 KHz). The coupling apparatus utilizes existing thyratron circuits and provides suitable power input to a large bore metal vapor laser while maintaining satisfactory operating lifetimes for the existing thyratron circuits.

  6. Coupling apparatus for a metal vapor laser

    DOEpatents

    Ball, Don G.; Miller, John L.

    1993-01-01

    Coupling apparatus for a large bore metal vapor laser is disclosed. The coupling apparatus provides for coupling high voltage pulses (approximately 40 KV) to a metal vapor laser with a high repetition rate (approximately 5 KHz). The coupling apparatus utilizes existing thyratron circuits and provides suitable power input to a large bore metal vapor laser while maintaining satisfactory operating lifetimes for the existing thyratron circuits.

  7. APPARATUS FOR ELECTRON BEAM HEATING CONTROL

    DOEpatents

    Jones, W.H.; Reece, J.B.

    1962-09-18

    An improved electron beam welding or melting apparatus is designed which utilizes a high voltage rectifier operating below its temperature saturation region to decrease variations in electron beam current which normally result from the gas generated in such apparatus. (AEC)

  8. An Apparatus for the Determination of Curie Temperature.

    ERIC Educational Resources Information Center

    Bates, P. A.; Kent, A. M.

    1980-01-01

    Described is an apparatus for determining the Curie temperature of a Ferromagnetic material which enables large specimens to be heated up to a maximum of 1100K in 20 minutes. Included is the theory, magnetic circuit apparatus, electrical circuit, and results using this apparatus. (DS)

  9. 75 FR 61386 - Emergency Escape Breathing Apparatus Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-05

    ...-0044, Notice No. 1] RIN 2130-AC14 Emergency Escape Breathing Apparatus Standards AGENCY: Federal... breathing apparatus (EEBA) to the members of the train crew and certain other employees while they are... EEBA--emergency escape breathing apparatus FRA--Federal Railroad Administration FRSA--the former...

  10. 46 CFR 160.010-3 - Inflatable buoyant apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Buoyant Apparatus for Merchant Vessels § 160.010... container accessible to the occupants, or otherwise secured to the apparatus. Duplicate equipment must be provided, for each side of a reversible inflatable buoyant apparatus, if the equipment is not accessible...

  11. 46 CFR 160.010-3 - Inflatable buoyant apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Buoyant Apparatus for Merchant Vessels § 160.010... container accessible to the occupants, or otherwise secured to the apparatus. Duplicate equipment must be provided, for each side of a reversible inflatable buoyant apparatus, if the equipment is not accessible...

  12. 29 CFR 1926.307 - Mechanical power-transmission apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 8 2011-07-01 2011-07-01 false Mechanical power-transmission apparatus. 1926.307 Section....307 Mechanical power-transmission apparatus. (a) General requirements. (1) This section covers all... keyways shall be filled up or covered. (5) Power-transmission apparatus located in basements. All...

  13. 29 CFR 1926.307 - Mechanical power-transmission apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Mechanical power-transmission apparatus. 1926.307 Section....307 Mechanical power-transmission apparatus. (a) General requirements. (1) This section covers all... keyways shall be filled up or covered. (5) Power-transmission apparatus located in basements. All...

  14. High-Temperature Hall-Effect Apparatus

    NASA Technical Reports Server (NTRS)

    Wood, C.; Lockwood, R. A.; Chemielewski, A. B.; Parker, J. B.; Zoltan, A.

    1985-01-01

    Compact furnace minimizes thermal gradients and electrical noise. Semiautomatic Hall-effect apparatus takes measurements on refractory semiconductors at temperatures as high as 1,100 degrees C. Intended especially for use with samples of high conductivity and low chargecarrier mobility that exhibit low signal-to-noise ratios, apparatus carefully constructed to avoid spurious electromagnetic and thermoelectric effects that further degrade measurements.

  15. Rotating Apparatus for Isoelectric Focusing

    NASA Technical Reports Server (NTRS)

    Bier, M.

    1986-01-01

    Remixing of separated fractions prevented. Improved isoelectric focusing apparatus helps to prevent electro-osmosis and convection, both of which cause remixing of separated fractions. Fractionating column segmented and rotated about horizontal axis: Only combined effects of both features fully effective in making good separations. Improved apparatus slowly rotated continuously or rocked (at rotational amplitude of at least 180 degrees) about its horizontal axis so average gravitational vector experienced by fluid is zero and convection is therefore suppressed. Electro-osmosis suppressed and convection further suppressed by separating column into disklike compartments along its length with filters. Experiments have shown dimensions of apparatus not critical. Typical compartment and column volumes are 2 and 40 ml, respectively. Rotation speeds lie between 3 and 30 rpm.

  16. Modular Apparatus and Method for Attaching Multiple Devices

    NASA Technical Reports Server (NTRS)

    Okojie, Robert S (Inventor)

    2015-01-01

    A modular apparatus for attaching sensors and electronics is disclosed. The modular apparatus includes a square recess including a plurality of cavities and a reference cavity such that a pressure sensor can be connected to the modular apparatus. The modular apparatus also includes at least one voltage input hole and at least one voltage output hole operably connected to each of the plurality of cavities such that voltage can be applied to the pressure sensor and received from the pressure sensor.

  17. 42 CFR 84.93 - Gas flow test; open-circuit apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Gas flow test; open-circuit apparatus. 84.93...-Contained Breathing Apparatus § 84.93 Gas flow test; open-circuit apparatus. (a) A static-flow test will be performed on all open-circuit apparatus. (b) The flow from the apparatus shall be greater than 200 liters...

  18. 42 CFR 84.93 - Gas flow test; open-circuit apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Gas flow test; open-circuit apparatus. 84.93...-Contained Breathing Apparatus § 84.93 Gas flow test; open-circuit apparatus. (a) A static-flow test will be performed on all open-circuit apparatus. (b) The flow from the apparatus shall be greater than 200 liters...

  19. 46 CFR 108.635 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... DESIGN AND EQUIPMENT Equipment Markings and Instructions § 108.635 Self-contained breathing apparatus. Each locker or space containing self-contained breathing apparatus must be marked: “SELF CONTAINED... 46 Shipping 4 2011-10-01 2011-10-01 false Self-contained breathing apparatus. 108.635 Section 108...

  20. 21 CFR 886.4100 - Radiofrequency electrosurgical cautery apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency electrosurgical cautery apparatus. 886.4100 Section 886.4100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... electrosurgical cautery apparatus. (a) Identification. A radiofrequency electrosurgical cautery apparatus is an AC...

  1. 21 CFR 886.4100 - Radiofrequency electrosurgical cautery apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Radiofrequency electrosurgical cautery apparatus. 886.4100 Section 886.4100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... electrosurgical cautery apparatus. (a) Identification. A radiofrequency electrosurgical cautery apparatus is an AC...

  2. 46 CFR 108.635 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... DESIGN AND EQUIPMENT Equipment Markings and Instructions § 108.635 Self-contained breathing apparatus. Each locker or space containing self-contained breathing apparatus must be marked: “SELF CONTAINED... 46 Shipping 4 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 108.635 Section 108...

  3. Exercise apparatus

    NASA Technical Reports Server (NTRS)

    Schaffner, Grant (Inventor); Bentley, Jason R. (Inventor); Loehr, James A. (Inventor); Gundo, Daniel P. (Inventor)

    2006-01-01

    An apparatus and method for exercising whereby the user is supported by various mechanisms in such as way that the user's shoulder area is free to translate and rotate; the user's pelvic area is free to translate and rotate; or in any combination.

  4. Apparatus Reviews.

    ERIC Educational Resources Information Center

    School Science Review, 1983

    1983-01-01

    Provided are reviews of science equipment/apparatus. Items reviewed include: Harris Micro-ecology tubes; Harris chromosome investigation kit; Harris trycult slides; a pressure cooker with thermometer; digital pH meter; digital scaler timer; electrical compensation calorimeter; and Mains alternating current ammeter. (JN)

  5. Microelectromechanical ratcheting apparatus

    DOEpatents

    Barnes, Stephen M.; Miller, Samuel L.; Jensen, Brian D.; Rodgers, M. Steven; Burg, Michael S.

    2001-01-01

    A microelectromechanical (MEM) ratcheting apparatus is disclosed which includes an electrostatic or thermal actuator that drives a moveable member in the form of a ring gear, stage, or rack. Motion is effected by one or more reciprocating pawls driven by the actuator in a direction that is parallel to, in line with, or tangential to the path. The reciprocating pawls engage indexing elements (e.g. teeth or pins) on the moveable member to incrementally move the member along a curved or straight path with the ability to precisely control and determine the position of the moveable member. The MEM apparatus can be formed on a silicon substrate by conventional surface micromachining methods.

  6. Analytical liquid test sample filtration apparatus

    DOEpatents

    Lohnes, B.C.; Turner, T.D.; Klingler, K.M.; Clark, M.L.

    1996-01-09

    A liquid sample filtration apparatus includes: (a) a module retaining filter elements; (b) a filter clamping and fluid injection apparatus positioned relative to the module to engage a filter element thereon, and includes a pair of first and second opposing engageable members to engage a filter element there between; (c) an inlet tube connected to an opposing engageable member; (d) an outlet tube connected to an opposing engageable member; (e) a motor to move the module relative to the filter clamping and injection apparatus to register filter elements on the module to the clamping and injection apparatus; and (f) a motor associated with the filter clamping and injection apparatus to move the opposing engageable members into substantial sealing fluid communication relative to a filter element on the module. An apparatus for engaging opposing ends of a filter element includes: (a) a member having a recess configured to engage one end of a filter element, including a first fluid passage communicating with the recess to pass fluid between the recess and externally of the member; and (b) a second member positioned in opposing juxtaposition relative to the other member, and having a projection sized and shaped to matingly fit within the other member recess, the second member projection including a second recess configured to engage the other end of the filter element, the second member including a second fluid passage communicating with the second recess to pass fluid between the second recess and externally of the second member. 8 figs.

  7. 21 CFR 870.5050 - Patient care suction apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Patient care suction apparatus. 870.5050 Section 870.5050 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... suction apparatus. (a) Identification. A patient care suction apparatus is a device used with an...

  8. 46 CFR 169.736 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 169.736 Section 169... VESSELS Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.736 Self-contained breathing apparatus. Each locker or space containing self-contained breathing apparatus must be marked “SELF-CONTAINED...

  9. 21 CFR 870.5050 - Patient care suction apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Patient care suction apparatus. 870.5050 Section 870.5050 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... suction apparatus. (a) Identification. A patient care suction apparatus is a device used with an...

  10. 46 CFR 169.736 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Self-contained breathing apparatus. 169.736 Section 169... VESSELS Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.736 Self-contained breathing apparatus. Each locker or space containing self-contained breathing apparatus must be marked “SELF-CONTAINED...

  11. 7 CFR 29.69 - Weighing apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Weighing apparatus. 29.69 Section 29.69 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Regulations Permissive Inspection § 29.69 Weighing apparatus. A scale used for determination of...

  12. 7 CFR 29.69 - Weighing apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Weighing apparatus. 29.69 Section 29.69 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Regulations Permissive Inspection § 29.69 Weighing apparatus. A scale used for determination of...

  13. Coordinated X-Y stage apparatus

    DOEpatents

    Morimoto, Alan K.; Kozlowski, David M.; Charles, Steven T.; Spalding, James A.

    2000-01-01

    An apparatus based on precision X-Y stages that are stacked. Attached to arms projecting from each X-Y stage are a set of two axis gimbals. Attached to the gimbals is a rod, which provides motion along the axis of the rod and rotation around its axis. A dual-planar apparatus that provides six degrees of freedom of motion precise to within microns of motion.

  14. Hydraulic Apparatus for Mechanical Testing of Nuts

    NASA Technical Reports Server (NTRS)

    Hinkel, Todd J.; Dean, Richard J.; Hacker, Scott C.; Harrington, Douglas W.; Salazar, Frank

    2004-01-01

    The figure depicts an apparatus for mechanical testing of nuts. In the original application for which the apparatus was developed, the nuts are of a frangible type designed for use with pyrotechnic devices in spacecraft applications in which there are requirements for rapid, one-time separations of structures that are bolted together. The apparatus can also be used to test nonfrangible nuts engaged without pyrotechnic devices. This apparatus was developed to replace prior testing systems that were extremely heavy and immobile and characterized by long setup times (of the order of an hour for each nut to be tested). This apparatus is mobile, and the setup for each test can now be completed in about five minutes. The apparatus can load a nut under test with a static axial force of as much as 6.8 x 10(exp 5) lb (3.0 MN) and a static moment of as much as 8.5 x 10(exp 4) lb in. (9.6 x 10(exp 3) N(raised dot)m) for a predetermined amount of time. In the case of a test of a frangible nut, the pyrotechnic devices can be exploded to break the nut while the load is applied, in which case the breakage of the nut relieves the load. The apparatus can be operated remotely for safety during an explosive test. The load-generating portion of the apparatus is driven by low-pressure compressed air; the remainder of the apparatus is driven by 110-Vac electricity. From its source, the compressed air is fed to the apparatus through a regulator and a manually operated valve. The regulated compressed air is fed to a pneumatically driven hydraulic pump, which pressurizes oil in a hydraulic cylinder, thereby causing a load to be applied via a hydraulic nut (not to be confused with the nut under test). During operation, the hydraulic pressure is correlated with the applied axial load, which is verified by use of a load cell. Prior to operation, one end of a test stud (which could be an ordinary threaded rod or bolt) is installed in the hydraulic nut. The other end of the test stud passes

  15. Lacrimal secretion stimulants: sigma receptors and drug implications.

    PubMed

    Shirolkar, S; Schoenwald, R D; Barfknecht, C F; Xia, E; Cheng, B; Iwai, Y; Ignace, C C; Vidvauns, S; Newton, R E

    1993-01-01

    3H-DTG (1.3-di(2-[5-3H]tolyl)guanidine) or 3H-haloperidol was added to sigma-receptors (25 nM) in the presence of 25 nM spiperone and incubated with increasing concentrations of bromhexine derivatives (phenylalkylamines; 10(-9) to 10(-2)M) in membrane homogenate suspensions. IC50 values for two derivatives ranged from 3.2 to 8.8 nM for both radioligands. A preferred derivative, 7A (N,N'-dimethyl-2-phenyl-ethylamine), yielded an IC50 of 7.8 nM for 3H-haloperidol but showed much less affinity in displacing 3H-DTG (IC50 = 900 nM). Applying the technic of Bromberg [Exp. Eye Res., 40:313-320, 1985], in vitro protein secretion rates were measured following stimulation of either lacrimal gland slices or isolated, intact lacrimocytes with the compounds. In vitro protein secretion rates exhibit a dose-response relationship with increases in protein release up to a concentration of 10(-8) to 10(-4) M for various derivatives of bromhexine and 10(-4) M for carbachol. By means of Schirmer strips, tear fluid was collected over a five minute period at 10 and 60 minutes post-dosing following the topical application (50 microliters) to the right eye of New Zealand white rabbits (n = 20-24) of 7A at various concentrations. Incubation of lacrimocytes with 7A alone (10(-4) M), with haloperidol (10(-4) M) alone or in combination show that 7A is acting as an agonist to stimulate protein release, whereas haloperidol is acting as an antagonist to inhibit release. In vivo protein secretion rates also show a dose-response curve (at both 10 and 60 minutes post-dosing) for 7A that reach a statistically significant maximum in the dosed eye at a concentration of 0.15% w/v. Analysis of protein extracts using size exclusion HPLC shows an increase in secretory proteins, particularly tear-specific prealbumin.

  16. Apparatus Reviews.

    ERIC Educational Resources Information Center

    School Science Review, 1981

    1981-01-01

    Reviews apparatus design and instructional uses for Fume Cupboard Monitor, Plant Tissue Culture Kit, various equipment for electronic systems course, Welwyn Microprocessor-Tutor, Sweep Function Generator SFG 606, and Harris manufacturers materials--Regulated Power Supply Units, Electronic Current and Voltage Meters, Gas Preparation Kit, and…

  17. Apparatus Notes

    ERIC Educational Resources Information Center

    Eaton, Bruce G., Ed.

    1977-01-01

    Presents four short articles on: a power supply for the measurement of the charge-to-mass ratio of the electron; a modified centripetal force apparatus; a black box electronic unknown for the scientific instruments laboratory; and a simple scaling model for biological systems. (MLH)

  18. 46 CFR 108.703 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... DESIGN AND EQUIPMENT Miscellaneous Equipment § 108.703 Self-contained breathing apparatus. (a) Each unit must be equipped with a self-contained breathing apparatus described in § 108.497(a) to use as... 46 Shipping 4 2011-10-01 2011-10-01 false Self-contained breathing apparatus. 108.703 Section 108...

  19. 46 CFR 108.703 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... DESIGN AND EQUIPMENT Miscellaneous Equipment § 108.703 Self-contained breathing apparatus. (a) Each unit must be equipped with a self-contained breathing apparatus described in § 108.497(a) to use as... 46 Shipping 4 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 108.703 Section 108...

  20. Electroplating method and apparatus

    DOEpatents

    Looney, Robert B.; Smith, William E. L.

    1978-06-20

    An apparatus for high speed electroplating or anodizing tubular members such as nuclear reactor fuel elements. A loading arm positions the member on a base for subsequent support by one of two sets of electrical contacts. A carriage assembly positions electrodes into and around the member. Electrolyte is pumped between the electrodes and the member while electric current is applied. Programmed controls sequentially employ each of the two sets of contacts to expose all surfaces of the member to the electrolyte. The member is removed from the apparatus by an unloading arm.

  1. BROACHING AND TUBE-INSTALLING APPARATUS

    DOEpatents

    Frantz, C.E.; Cawley, W.E.

    1961-05-16

    An apparatus is given for sizing long holes in graphite bodies. The apparatus comprises a shaft having 3 spiral broach cutting elements and a straight broach cutting element rotatably mounted thereon. The broach cutting elements are keyed to each other in end to end relationship with the straight broach cutting element at one end of the shaft. The spiral broach cutting elements when considered toward the straight broach cutting element increase in diameter and the cutting teeth thereon increase in lead angle. The straight broach cutting element, when considered in the same direction, increases in diameter from the minimum to maximum diameters of the spiral broach cutting elements. No longitudinal movement of the broach cutting elements is permitted on the shsft snd means are provided for the removal of chips from the apparatus.

  2. Optical apparatus for forming correlation spectrometers and optical processors

    DOEpatents

    Butler, Michael A.; Ricco, Antonio J.; Sinclair, Michael B.; Senturia, Stephen D.

    1999-01-01

    Optical apparatus for forming correlation spectrometers and optical processors. The optical apparatus comprises one or more diffractive optical elements formed on a substrate for receiving light from a source and processing the incident light. The optical apparatus includes an addressing element for alternately addressing each diffractive optical element thereof to produce for one unit of time a first correlation with the incident light, and to produce for a different unit of time a second correlation with the incident light that is different from the first correlation. In preferred embodiments of the invention, the optical apparatus is in the form of a correlation spectrometer; and in other embodiments, the apparatus is in the form of an optical processor. In some embodiments, the optical apparatus comprises a plurality of diffractive optical elements on a common substrate for forming first and second gratings that alternately intercept the incident light for different units of time. In other embodiments, the optical apparatus includes an electrically-programmable diffraction grating that may be alternately switched between a plurality of grating states thereof for processing the incident light. The optical apparatus may be formed, at least in part, by a micromachining process.

  3. Optical apparatus for forming correlation spectrometers and optical processors

    DOEpatents

    Butler, M.A.; Ricco, A.J.; Sinclair, M.B.; Senturia, S.D.

    1999-05-18

    Optical apparatus is disclosed for forming correlation spectrometers and optical processors. The optical apparatus comprises one or more diffractive optical elements formed on a substrate for receiving light from a source and processing the incident light. The optical apparatus includes an addressing element for alternately addressing each diffractive optical element thereof to produce for one unit of time a first correlation with the incident light, and to produce for a different unit of time a second correlation with the incident light that is different from the first correlation. In preferred embodiments of the invention, the optical apparatus is in the form of a correlation spectrometer; and in other embodiments, the apparatus is in the form of an optical processor. In some embodiments, the optical apparatus comprises a plurality of diffractive optical elements on a common substrate for forming first and second gratings that alternately intercept the incident light for different units of time. In other embodiments, the optical apparatus includes an electrically-programmable diffraction grating that may be alternately switched between a plurality of grating states thereof for processing the incident light. The optical apparatus may be formed, at least in part, by a micromachining process. 24 figs.

  4. Support apparatus for semiconductor wafer processing

    DOEpatents

    Griffiths, Stewart K.; Nilson, Robert H.; Torres, Kenneth J.

    2003-06-10

    A support apparatus for minimizing gravitational stress in semiconductor wafers, and particularly silicon wafers, during thermal processing. The support apparatus comprises two concentric circular support structures disposed on a common support fixture. The two concentric circular support structures, located generally at between 10 and 70% and 70 and 100% and preferably at 35 and 82.3% of the semiconductor wafer radius, can be either solid rings or a plurality of spaced support points spaced apart from each other in a substantially uniform manner. Further, the support structures can have segments removed to facilitate wafer loading and unloading. In order to withstand the elevated temperatures encountered during semiconductor wafer processing, the support apparatus, including the concentric circular support structures and support fixture can be fabricated from refractory materials, such as silicon carbide, quartz and graphite. The claimed wafer support apparatus can be readily adapted for use in either batch or single-wafer processors.

  5. Apparatus Named After Our Academic Ancestors — II

    NASA Astrophysics Data System (ADS)

    Greenslade, Thomas B.

    2011-01-01

    In my previous article on apparatus named after physicists and physics teachers, I discussed five relatively common pieces of apparatus from the 1875-1910 era. Now I will go back to the 18th and early-19th centuries to discuss eponymous2 apparatus that we are still using in lecture demonstrations.

  6. Apparatus Notes.

    ERIC Educational Resources Information Center

    Eaton, Bruce G., Ed.

    1981-01-01

    Describes experiments and apparatus to: (1) allow astronomy students to test resolution limit of their eyes at several wavelengths; (2) analyze laser mode phases by interferometry; (3) demonstrate a Cartesian diver with an overhead projector; and (4) generate conical beams of light for smoke-chamber demonstrations. (JN)

  7. Apparatus Reviews.

    ERIC Educational Resources Information Center

    School Science Review, 1978

    1978-01-01

    Describes some science apparatus: included are a gene kit to demonstrate aspects of population genetics and selection, an electronic thermometer for use in the field of environmental studies, an astrobrella to use in astronomy classes, and crystal display models of different substances for chemistry classes. (GA)

  8. Apparatus Notes.

    ERIC Educational Resources Information Center

    Eaton, Bruce G., Ed.

    1980-01-01

    This collection of notes describes (1) an optoelectronic apparatus for classroom demonstrations of mechanical laws, (2) a more efficient method for demonstrated nuclear chain reactions using electrically energized "traps" and ping-pong balls, and (3) an inexpensive demonstration for qualitative analysis of temperature-dependent resistance. (CS)

  9. A case of non-lacrimal immunoglobulin G4 (IgG4)-related orbital disease with mastitis.

    PubMed

    Farooq, Tahir Ali; Mudhar, Hardeep; Sandramouli, S

    2016-01-01

    IgG4-related orbital disease is a recognised cause for orbital inflammation. As its awareness increases and diagnostic accuracy improves there will be an increased number of cases being identified. This unique case demonstrates for the first time, with histological evidence, a case of a non-lacrimal IgG4-related orbital disease with concurrent IgG4-related mastitis. We describe a 47 year old who presented with a supraorbital swelling and mass. This was initially successfully treated with oral steroids and was later excised on recurrence. Immunohistochemical and blood serum analysis confirmed IgG4-related orbital disease. On systemic enquiry she was found to have a mass of the breast, which was shown to be IgG4-related mastitis. She is currently asymptomatic with no sign of recurrence and is under long-term surveillance. This case highlights the importance of systemic work up in patients presenting with orbital foci of IgG4 disease.

  10. Autoimmune Granulomatous Inflammation of Lacrimal Glands and Axonal Neuritis Following Treatment With Ipilimumab and Radiation Therapy.

    PubMed

    Ileana Dumbrava, Ecaterina; Smith, Veronica; Alfattal, Rasha; El-Naggar, Adel K; Penas-Prado, Marta; Tsimberidou, Apostolia M

    2018-05-21

    Immune checkpoint inhibitors such as anti-CTLA-4 (cytotoxic T-lymphocyte-associated protein 4), anti PD-1 (programmed cell death protein 1) and PD-L1 (programmed cell death protein-ligand 1) monoclonal antibodies are emerging as standard oncology treatments in various tumor types. The indications will expand as immunotherapies are being investigated in various tumors with promising results. Currently, there is inadequate identification of predictive biomarkers of response or toxicity. Unique response patterns include pseudoprogression and delayed response. The use of immune checkpoint inhibitors exhibit an unique toxicity profile, the immune-related adverse events (irAEs). The most notable immune reactions are noted in skin (rash), gastrointestinal track (colitis, hepatitis, pancreatitis), lung (pneumonitis), heart (myocarditis), and endocrine system (thyroiditis, hypophysitis). We present a patient with metastatic adenoid cystic carcinoma of the left submandibular gland with granulomatous inflammation of the lacrimal glands and axonal neuritis of the cervical and paraspinal nerves following treatment with ipilimumab and radiation therapy.

  11. Core drilling apparatus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gusman, M.T.; Konstantinov, L.P.; Malkin, B.D.

    1974-04-16

    Mounted on the exterior of a nonrotatable core barrel is an end of a resilient tape, the other end of which extends inward into the barrel and is connected to a device for pulling the tape inward into the barrel. The apparatus also is provided with an arrangement which forms a sleeve from the tape as this is being pulled into the core barrel. During the coring operation, the tape is being pulled inward into the barrel and a sleeve is formed from the tape with the aid of the arrangement to encase and protect the core from disturbance. Themore » coring apparatus is intended for core drilling in soft, unconsolidated, and fractured formations. (3 claims)« less

  12. 42 CFR 84.71 - Self-contained breathing apparatus; required components.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Self-contained breathing apparatus; required...-Contained Breathing Apparatus § 84.71 Self-contained breathing apparatus; required components. (a) Each self-contained breathing apparatus described in § 84.70 shall, where its design requires, contain the following...

  13. 42 CFR 84.71 - Self-contained breathing apparatus; required components.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Self-contained breathing apparatus; required...-Contained Breathing Apparatus § 84.71 Self-contained breathing apparatus; required components. (a) Each self-contained breathing apparatus described in § 84.70 shall, where its design requires, contain the following...

  14. Duplex sampling apparatus and method

    DOEpatents

    Brown, Paul E.; Lloyd, Robert

    1992-01-01

    An improved apparatus is provided for sampling a gaseous mixture and for measuring mixture components. The apparatus includes two sampling containers connected in series serving as a duplex sampling apparatus. The apparatus is adapted to independently determine the amounts of condensable and noncondensable gases in admixture from a single sample. More specifically, a first container includes a first port capable of selectively connecting to and disconnecting from a sample source and a second port capable of selectively connecting to and disconnecting from a second container. A second container also includes a first port capable of selectively connecting to and disconnecting from the second port of the first container and a second port capable of either selectively connecting to and disconnecting from a differential pressure source. By cooling a mixture sample in the first container, the condensable vapors form a liquid, leaving noncondensable gases either as free gases or dissolved in the liquid. The condensed liquid is heated to drive out dissolved noncondensable gases, and all the noncondensable gases are transferred to the second container. Then the first and second containers are separated from one another in order to separately determine the amount of noncondensable gases and the amount of condensable gases in the sample.

  15. Time course of ocular surface and lacrimal gland changes in a new scopolamine-induced dry eye model.

    PubMed

    Viau, Sabrina; Maire, Marie-Annick; Pasquis, Bruno; Grégoire, Stéphane; Fourgeux, Cynthia; Acar, Niyazi; Bretillon, Lionel; Creuzot-Garcher, Catherine P; Joffre, Corinne

    2008-06-01

    The aim of this study was to set up an animal model of dry eye showing disturbance in several components of the lacrimal functional unit, and to describe the time course of the appearance of clinical signs and inflammatory markers. Dry eye was induced in 6-week-old female Lewis rats by a systemic and continuous delivery of scopolamine via osmotic pumps implanted subcutaneously. We first determined the appropriate dose of scopolamine (6, 12.5, or 25 mg/day) for 28 days. In a second set of experiments, we determined markers after 1, 2, 3, 7, 10, 17, or 28 days of a 12.5-mg/day dose. Clinical signs of corneal dryness were evaluated in vivo using fluorescein staining. MHC II expression and mucin Muc5AC production were detected on the conjunctival epithelium using immunostaining. The level of IL-1beta, IL-6, TNF-alpha, and IFN-gamma mRNA was evaluated by real-time polymerase chain reaction in conjunctiva and exorbital lacrimal gland (LG). Lipids were extracted from the exorbital LG for fatty acid analysis. Daily scopolamine doses of 12.5 mg and 25 mg applied for a 28-day period induced keratitis, a decrease in Muc5AC immunostaining density in the conjunctival epithelium, and modifications in the fatty acid composition of the exorbital LG. Animals treated with a 12.5-mg/day dose of scopolamine exhibited an increase in corneal fluorescein staining after 2, 10, and 28 days. All animals exhibited unilateral or bilateral keratitis after 17 days. In the conjunctival epithelium, a significant decrease in Muc5AC immunostaining density was observed at early and late time points, and MHC II expression tended to be increased after 1, 7, 10, and 28 days, without reaching statistical significance. The levels of TNF-alpha, IL-1beta and IL-6 mRNA were increased with scopolamine treatment in both conjunctiva and exorbital LG. Arachidonic acid and the Delta5 desaturase index were significantly increased in the exorbital LG of dry eye animals at each time point. This systemic and

  16. Locking apparatus for gate valves

    DOEpatents

    Fabyan, J.; Williams, C.W.

    A locking apparatus for fluid operated valves having a piston connected to the valve actuator which moves in response to applied pressure within a cylinder housing having a cylinder head, a catch block is secured to the piston, and the cylinder head incorporates a catch pin. Pressure applied to the cylinder to open the valve moves the piston adjacent to the cylinder head where the catch pin automatically engages the catch block preventing further movement of the piston or premature closure of the valve. Application of pressure to the cylinder to close the valve, retracts the catch pin, allowing the valve to close. Included are one or more selector valves, for selecting pressure application to other apparatus depending on the gate valve position, open or closed, protecting such apparatus from damage due to premature closing caused by pressure loss or operational error.

  17. Apparatus and method for gelling liquefied gasses

    NASA Technical Reports Server (NTRS)

    Elliott, Adam (Inventor); DiSalvo, Roberto (Inventor); Shepherd, Phillip (Inventor); Kosier, Ryan (Inventor)

    2010-01-01

    The present invention is a method and apparatus for gelling liquid propane and other liquefied gasses. The apparatus includes a temperature controlled churn mixer, vacuum pump, liquefied gas transfer tank, and means for measuring amount of material entering the mixer. The method uses gelling agents such as silicon dioxide, clay, carbon, or organic or inorganic polymers, as well as dopants such as titanium, aluminum, and boron powders. The apparatus and method are particularly useful for the production of high quality rocket fuels and propellants.

  18. 42 CFR 84.96 - Service time test; closed-circuit apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Service time test; closed-circuit apparatus. 84.96...-Contained Breathing Apparatus § 84.96 Service time test; closed-circuit apparatus. (a) The closed-circuit apparatus will be classified according to the length of time it supplies adequate breathing gas to the...

  19. 42 CFR 84.94 - Gas flow test; closed-circuit apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Gas flow test; closed-circuit apparatus. 84.94...-Contained Breathing Apparatus § 84.94 Gas flow test; closed-circuit apparatus. (a) Where oxygen is supplied... rated service time of the apparatus. (b) Where constant flow is used in conjunction with demand flow...

  20. 42 CFR 84.96 - Service time test; closed-circuit apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Service time test; closed-circuit apparatus. 84.96...-Contained Breathing Apparatus § 84.96 Service time test; closed-circuit apparatus. (a) The closed-circuit apparatus will be classified according to the length of time it supplies adequate breathing gas to the...

  1. 42 CFR 84.94 - Gas flow test; closed-circuit apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Gas flow test; closed-circuit apparatus. 84.94...-Contained Breathing Apparatus § 84.94 Gas flow test; closed-circuit apparatus. (a) Where oxygen is supplied... rated service time of the apparatus. (b) Where constant flow is used in conjunction with demand flow...

  2. 49 CFR 234.211 - Security of warning system apparatus.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Security of warning system apparatus. 234.211 Section 234.211 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD....211 Security of warning system apparatus. Highway-rail grade crossing warning system apparatus shall...

  3. 49 CFR 234.211 - Security of warning system apparatus.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Security of warning system apparatus. 234.211 Section 234.211 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD....211 Security of warning system apparatus. Highway-rail grade crossing warning system apparatus shall...

  4. 49 CFR 234.211 - Security of warning system apparatus.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Security of warning system apparatus. 234.211 Section 234.211 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD....211 Security of warning system apparatus. Highway-rail grade crossing warning system apparatus shall...

  5. Apparatus and method for selectively channeling a fluid

    DOEpatents

    Rightley, Michael Joseph [Albuquerque, NM

    2008-01-01

    An apparatus for selectively channeling a high temperature fluid without chemically reacting with the fluid. The apparatus includes an inlet and a membrane positioned adjacent to the inlet, each composed of a chemically inert material. The membrane is formed by compressive preloading techniques. The apparatus further includes a seat disposed on the inlet adjacent to the membrane. The seat is composed of a heat resistant and chemically inert material. Operation of the apparatus requires that the temperature of the fluid remains below the chemical characteristic melting point of the seat. The apparatus further includes an actuator coupled to the membrane for rendering the membrane in an open and a closed position with respect to the seat. Specifically, the actuator supplies a load in the normal direction to the membrane to selectively engage the membrane in a plurality of predetermined configurations. Operatively, the apparatus receives the fluid at the inlet. The fluid is received at a high temperature and is directed from the inlet to the membrane. In the closed position, the actuator engages the membrane to prevent the fluid from flowing from the inlet between the membrane and the seat. Alternatively, in the open position, the actuator engages the membrane to permit fluid flow from the inlet between the membrane and the seat to at least one outlet provided by the apparatus. In one exemplary embodiment, the fluid may be discharged from the at least one outlet to a sensor in fluid communication with the at least one outlet. Accordingly, the sensor may measure the fluid channeled through the heat resistant and chemically inert environment provided by the apparatus.

  6. Sample positioning apparatus

    DOEpatents

    Bell, Thomas H.; Johnson, Jr., Charles H.; Lane, Robert L.; Martin, Bradley E.; Tyree, William H.

    1976-01-06

    Apparatus for use in alpha particle counting with such as photomultiplier tubes, comprising a platform and linkage mechanism whereby samples are moved in linear manner toward and away from ends of the photomultiplier tubes.

  7. Endoscopic placement of Jones lacrimal tubes with the assistance of holmium YAG laser.

    PubMed

    Boboridis, Kostas G; Downes, Richard N

    2005-06-01

    The aim of this paper is to highlight the use of the Holmium YAG laser in the endoscopic placement of Lester Jones tubes in patients with a blocked canaliculus or failed lacrimal pump function. Sixteen cases with a non-functional canaliculus were included over a one-year period. Following caruncle excision, a 19 G needle is inserted through the medial canthal tissues into the nasal space. Nasal endoscopy confirms the accurate positioning in relation to the nasal anatomy. With the Holmium YAG laser, a tissue channel is fashioned around the guide needle through the structures of the lateral nasal wall to facilitate an accurate and secure placement of the Jones tube. The endoscopic, laser-assisted placement reduces the operating time to less than 20 minutes, minimizes tissue trauma and does not require the initial surgical steps of an open DCR procedure. There were 14 cases (87.5%) with securely retained tubes and two cases (12.5%) that required tube replacement. The advantage of the procedure is especially great in revision surgery where the ostium is opened through scar tissue. Nasal endoscopy with the assistance of the Holmium YAG laser offers simplicity and precision in the placement of Jones tubes. It minimizes tissue trauma and increases the surgical success rate.

  8. 42 CFR 84.95 - Service time test; open-circuit apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Service time test; open-circuit apparatus. 84.95...-Contained Breathing Apparatus § 84.95 Service time test; open-circuit apparatus. (a) Service time will be measured with a breathing machine as described in § 84.88. (b) The open-circuit apparatus will be...

  9. 42 CFR 84.95 - Service time test; open-circuit apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Service time test; open-circuit apparatus. 84.95...-Contained Breathing Apparatus § 84.95 Service time test; open-circuit apparatus. (a) Service time will be measured with a breathing machine as described in § 84.88. (b) The open-circuit apparatus will be...

  10. Gas shielding apparatus

    DOEpatents

    Brandt, D.

    1984-06-05

    An apparatus for preventing oxidation by uniformly distributing inert shielding gas over the weld area of workpieces such as pipes being welded together. The apparatus comprises a chamber and a gas introduction element. The chamber has an annular top wall, an annular bottom wall, an inner side wall and an outer side wall connecting the top and bottom walls. One side wall is a screen and the other has a portion defining an orifice. The gas introduction element has a portion which encloses the orifice and can be one or more pipes. The gas introduction element is in fluid communication with the chamber and introduces inert shielding gas into the chamber. The inert gas leaves the chamber through the screen side wall and is dispersed evenly over the weld area.

  11. Gas shielding apparatus

    DOEpatents

    Brandt, D.

    1985-12-31

    An apparatus is disclosed for preventing oxidation by uniformly distributing inert shielding gas over the weld area of workpieces such as pipes being welded together. The apparatus comprises a chamber and a gas introduction element. The chamber has an annular top wall, an annular bottom wall, an inner side wall and an outer side wall connecting the top and bottom walls. One side wall is a screen and the other has a portion defining an orifice. The gas introduction element has a portion which encloses the orifice and can be one or more pipes. The gas introduction element is in fluid communication with the chamber and introduces inert shielding gas into the chamber. The inert gas leaves the chamber through the screen side wall and is dispersed evenly over the weld area. 3 figs.

  12. Gas shielding apparatus

    DOEpatents

    Brandt, Daniel

    1985-01-01

    An apparatus for preventing oxidation by uniformly distributing inert shielding gas over the weld area of workpieces such as pipes being welded together. The apparatus comprises a chamber and a gas introduction element. The chamber has an annular top wall, an annular bottom wall, an inner side wall and an outer side wall connecting the top and bottom walls. One side wall is a screen and the other has a portion defining an orifice. The gas introduction element has a portion which encloses the orifice and can be one or more pipes. The gas introduction element is in fluid communication with the chamber and introduces inert shielding gas into the chamber. The inert gas leaves the chamber through the screen side wall and is dispersed evenly over the weld area.

  13. FUSION WELDING METHOD AND APPARATUS

    DOEpatents

    Wyman, W.L.; Steinkamp, W.I.

    1961-01-17

    An apparatus for the fusion welding of metal pieces at a joint is described. The apparatus comprises a highvacuum chamber enclosing the metal pieces and a thermionic filament emitter. Sufficient power is applied to the emitter so that when the electron emission therefrom is focused on the joint it has sufficient energy to melt the metal pieces, ionize the metallic vapor abcve the molten metal, and establish an arc discharge between the joint and the emitter.

  14. 49 CFR 234.211 - Security of warning system apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Security of warning system apparatus. 234.211... Maintenance, Inspection, and Testing Maintenance Standards § 234.211 Security of warning system apparatus. Highway-rail grade crossing warning system apparatus shall be secured against unauthorized entry. ...

  15. 49 CFR 234.211 - Security of warning system apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Security of warning system apparatus. 234.211... Maintenance, Inspection, and Testing Maintenance Standards § 234.211 Security of warning system apparatus. Highway-rail grade crossing warning system apparatus shall be secured against unauthorized entry. ...

  16. 49 CFR 236.3 - Locking of signal apparatus housings.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Locking of signal apparatus housings. 236.3 Section 236.3 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... Instructions: All Systems General § 236.3 Locking of signal apparatus housings. Signal apparatus housings shall...

  17. 49 CFR 236.3 - Locking of signal apparatus housings.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking of signal apparatus housings. 236.3 Section 236.3 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... Instructions: All Systems General § 236.3 Locking of signal apparatus housings. Signal apparatus housings shall...

  18. Sewage treatment method and apparatus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Engelmann, J.A.

    1982-07-13

    A method and apparatus for treating sewage and converting the sewage into organic fertilizer which utilizes equipment for converting the solid material of the sewage into patties and a mixing apparatus for mixing the patties with bulking agents. The mixture of patties and bulking agents is stored in a pile and subjected to a supply of air to enhance the self-combustion or oxidation of the organic material in the patties. The bulking agents provide the patty-bulking agent mixture with air passages and pockets and minimize compaction of the patties. The selfcombustion of the patties continues until the organic material ismore » burned out, leaving a residual ash. A shaker separator having an elongated longitudinal perforated member is reciprocated to separate the ash from the bulking agents. The ash is collected and utilized as organic fertilizer. The bulking agents are recycled back to the mixing apparatus.« less

  19. A Modification to Maxwell's Needle Apparatus

    ERIC Educational Resources Information Center

    Soorya, Tribhuvan N.

    2015-01-01

    Maxwell's needle apparatus is used to determine the shear modulus (?) of the material of a wire of uniform cylindrical cross section. Conventionally, a single observation is taken for each observable, and the value of ? is calculated in a single shot. A modification to the above apparatus is made by varying one of the observables, namely the mass…

  20. Apparatus For Tests Of Percussion Primers

    NASA Technical Reports Server (NTRS)

    Bement, Laurence J.; Bailey, James W.; Schimmel, Morry L.

    1991-01-01

    Test apparatus and method developed to measure ignition capability of percussion primers. Closely simulates actual conditions and interfaces encountered in such applications as in munitions and rocket motors. Ignitability-testing apparatus is small bomb instrumented with pressure transducers. Sizes, shapes, and positions of bomb components and materials under test selected to obtain quantitative data on ignition.

  1. 21 CFR 862.2485 - Electrophoresis apparatus for clinical use.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Electrophoresis apparatus for clinical use. 862... Instruments § 862.2485 Electrophoresis apparatus for clinical use. (a) Identification. An electrophoresis apparatus for clinical use is a device intended to separate molecules or particles, including plasma...

  2. 7 CFR 801.9 - Tolerances for test weight apparatuses.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... PERFORMANCE REQUIREMENTS FOR GRAIN INSPECTION EQUIPMENT § 801.9 Tolerances for test weight apparatuses. The maintenance tolerances for test weight per bushel apparatuses used in performing official inspection services... 7 Agriculture 7 2011-01-01 2011-01-01 false Tolerances for test weight apparatuses. 801.9 Section...

  3. 7 CFR 801.9 - Tolerances for test weight apparatuses.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... PERFORMANCE REQUIREMENTS FOR GRAIN INSPECTION EQUIPMENT § 801.9 Tolerances for test weight apparatuses. The maintenance tolerances for test weight per bushel apparatuses used in performing official inspection services... 7 Agriculture 7 2010-01-01 2010-01-01 false Tolerances for test weight apparatuses. 801.9 Section...

  4. 21 CFR 862.2485 - Electrophoresis apparatus for clinical use.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electrophoresis apparatus for clinical use. 862... Instruments § 862.2485 Electrophoresis apparatus for clinical use. (a) Identification. An electrophoresis apparatus for clinical use is a device intended to separate molecules or particles, including plasma...

  5. Turbocharger apparatus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leavesley, M.G.

    1993-08-03

    Variable turbocharger apparatus is described comprising a compressor housing, a compressor mounted for rotation in the compressor housing, a turbine housing, a turbine mounted for rotation in the turbine housing, a first inlet for enabling air to be conducted to the compressor, an outlet for air from the compressor, a second inlet for enabling exhaust gases from an engine to be conducted to the turbine, a chamber which surrounds the turbine and which receives the exhaust gases from the second inlet before the exhaust gases are conducted to the turbine, a piston which is positioned between the turbine and themore » turbine housing and which is slidable backwards and forwards to form a movable wall separating the turbine from the chamber which surrounds the turbine, a bearing assembly for allowing the rotation of the compressor and the turbine, and a heat shield for shielding the bearing assembly from the exhaust gases, the piston having a plurality of vanes, the piston being such that in its closed position it terminates short of an adjacent part of the turbine housing so that there is always a gap between the end of the piston and the adjacent part of the turbine housing whereby exhaust gases from the chamber can always pass through the gap to act on the turbine, the piston being such that in its open position the gap is increased, and the piston being biased to its closed position against pressure from exhaust gases in the chamber during use of the variable turbocharger apparatus whereby the piston slides backwards and forwards to vary the gap in dependence upon engine operating conditions, and the variable turbocharger apparatus being such that the vanes on the piston enter into slots in the heat shield.« less

  6. Prehensile apparatus

    DOEpatents

    Smith, Christopher M.

    1993-01-01

    The present invention relates to an apparatus for handling a workpiece comprising a vessel that is longitudinally extensible and pressurizable, and a nonextensible and laterally flexible member on the vessel. The member constrains one side of the vessel to be nonextensible, causing the vessel to bend in the direction of the nonextensible member when pressurized.

  7. Apparatus for testing for infection by a retrovirus

    DOEpatents

    Layne, Scott P.; Beugelsdijk, Tony J.

    1999-01-01

    An apparatus for testing specimens for infection by a retrovirus is described. The apparatus comprises a process controller including a communications module for translating user commands into test instrument suite commands and a means for communicating specimen test results to a user. The apparatus further comprises a test instrument suite including a means for treating the specimen to manifest an observable result and a detector for measuring the observable result.

  8. Electrolysis Apparatus and a Method of Hydrodynamic Cavitation Protection.

    DTIC Science & Technology

    1974-09-17

    AD-DO01 178 ELECTROLYSIS APPARATUS AND A METHOD OF HYDRODYNAMIC CAVITATION PROTECTION Earl Quandt, et al Department of the Navy Washington, D. C. 17...213" 261123 , Navy Case No. 57,238 ELECTROLYSIS APPARATUS AND A METHOD OF HYDRODYNAMIC CAVITATION PROTECTION 1 ABSTRACT Method of and apparatus for

  9. 46 CFR 195.30-15 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Self-contained breathing apparatus. 195.30-15 Section... VESSELS VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Protection From Refrigerants § 195.30-15 Self-contained breathing apparatus. (a) Each vessel must have a self-contained breathing apparatus for...

  10. 46 CFR 195.30-15 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 195.30-15 Section... VESSELS VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Protection From Refrigerants § 195.30-15 Self-contained breathing apparatus. (a) Each vessel must have a self-contained breathing apparatus for...

  11. 30 CFR 14.21 - Laboratory-scale flame test apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Laboratory-scale flame test apparatus. 14.21 Section 14.21 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING... Technical Requirements § 14.21 Laboratory-scale flame test apparatus. The principal parts of the apparatus...

  12. 46 CFR 96.30-15 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 96.30-15 Section 96... VESSELS VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Protection From Refrigerants § 96.30-15 Self-contained breathing apparatus. (a) Each vessel must have a self-contained breathing apparatus for...

  13. 46 CFR 96.30-15 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Self-contained breathing apparatus. 96.30-15 Section 96... VESSELS VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Protection From Refrigerants § 96.30-15 Self-contained breathing apparatus. (a) Each vessel must have a self-contained breathing apparatus for...

  14. 30 CFR 14.21 - Laboratory-scale flame test apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Laboratory-scale flame test apparatus. 14.21 Section 14.21 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING... Technical Requirements § 14.21 Laboratory-scale flame test apparatus. The principal parts of the apparatus...

  15. Expendable oceanographic sensor apparatus

    DOEpatents

    McCoy, Kim O.; Downing, Jr., John P.; DeRoos, Bradley G.; Riches, Michael R.

    1993-01-01

    An expendable oceanographic sensor apparatus is deployed from an airplane or a ship to make oceanographic observations in a profile of the surface-to-ocean floor, while deployed on the floor, and then a second profile when returning to the ocean surface. The device then records surface conditions until on-board batteries fail. All data collected is stored and then transmitted from the surface to either a satellite or other receiving station. The apparatus is provided with an anchor that causes descent to the ocean floor and then permits ascent when the anchor is released. Anchor release is predetermined by the occurrence of a pre-programmed event.

  16. Agglomerating combustor-gasifier method and apparatus for coal gasification

    DOEpatents

    Chen, Joseph L. P.; Archer, David H.

    1976-09-21

    A method and apparatus for gasifying coal wherein the gasification takes place in a spout fluid bed at a pressure of about 10 to 30 atmospheres and a temperature of about 1800.degree. to 2200.degree.F and wherein the configuration of the apparatus and the manner of introduction of gases for combustion and fluidization is such that agglomerated ash can be withdrawn from the bottom of the apparatus and gas containing very low dust loading is produced. The gasification reaction is self-sustaining through the burning of a stoichiometric amount of coal with air in the lower part of the apparatus to form the spout within the fluid bed. The method and apparatus are particularly suitable for gasifying coarse coal particles.

  17. Two-dimensional heat flow apparatus

    NASA Astrophysics Data System (ADS)

    McDougall, Patrick; Ayars, Eric

    2014-06-01

    We have created an apparatus to quantitatively measure two-dimensional heat flow in a metal plate using a grid of temperature sensors read by a microcontroller. Real-time temperature data are collected from the microcontroller by a computer for comparison with a computational model of the heat equation. The microcontroller-based sensor array allows previously unavailable levels of precision at very low cost, and the combination of measurement and modeling makes for an excellent apparatus for the advanced undergraduate laboratory course.

  18. A patient transfer apparatus between bed and stretcher.

    PubMed

    Wang, Hongbo; Kasagami, Fumio

    2008-02-01

    This paper presents a patient transfer apparatus between bed and stretcher. This apparatus makes it possible for the nurse to move weak, injured, or paralyzed patient from bed to stretcher, or vice versa, alone. Moreover, the suffering, stress, and uneasy feeling of the patient can be alleviated. This paper describes the specification, mechanical design, control system, and motion control of the apparatus. A special devised mechanism is developed, and a new servo system is used in this control system. The control principle and algorithm of the new servo system are proposed, and the motion-control method and safety function of the apparatus are described. The experimental results and evaluation indicated the effectiveness of this system.

  19. Apparatus and method for handheld sampling

    DOEpatents

    Staab, Torsten A.

    2005-09-20

    The present invention includes an apparatus, and corresponding method, for taking a sample. The apparatus is built around a frame designed to be held in at least one hand. A sample media is used to secure the sample. A sample media adapter for securing the sample media is operated by a trigger mechanism connectively attached within the frame to the sample media adapter.

  20. Crystal growth and annealing method and apparatus

    DOEpatents

    Gianoulakis, Steven E.; Sparrow, Robert

    2001-01-01

    A method and apparatus for producing crystals that minimizes birefringence even at large crystal sizes, and is suitable for production of CaF.sub.2 crystals. The method of the present invention comprises annealing a crystal by maintaining a minimal temperature gradient in the crystal while slowly reducing the bulk temperature of the crystal. An apparatus according to the present invention includes a thermal control system added to a crystal growth and annealing apparatus, wherein the thermal control system allows a temperature gradient during crystal growth but minimizes the temperature gradient during crystal annealing. An embodiment of the present invention comprises a secondary heater incorporated into a conventional crystal growth and annealing apparatus. The secondary heater supplies heat to minimize the temperature gradients in the crystal during the annealing process. The secondary heater can mount near the bottom of the crucible to effectively maintain appropriate temperature gradients.

  1. 46 CFR 97.37-20 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 97.37-20 Section 97... VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-20 Self-contained breathing apparatus. (a) Lockers or spaces containing self-contained breathing apparatus shall be marked “SELF...

  2. 46 CFR 97.37-20 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Self-contained breathing apparatus. 97.37-20 Section 97... VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-20 Self-contained breathing apparatus. (a) Lockers or spaces containing self-contained breathing apparatus shall be marked “SELF...

  3. Optical fiber stripper positioning apparatus

    DOEpatents

    Fyfe, Richard W.; Sanchez, Jr., Amadeo

    1990-01-01

    An optical fiber positioning apparatus for an optical fiber stripping device is disclosed which is capable of providing precise axial alignment between an optical fiber to be stripped of its outer jacket and the cutting blades of a stripping device. The apparatus includes a first bore having a width approximately equal to the diameter of an unstripped optical fiber and a counter bore axially aligned with the first bore and dimensioned to precisely receive a portion of the stripping device in axial alignment with notched cutting blades within the stripping device to thereby axially align the notched cutting blades of the stripping device with the axis of the optical fiber to permit the notched cutting blades to sever the jacket on the optical fiber without damaging the cladding on the optical fiber. In a preferred embodiment, the apparatus further includes a fiber stop which permits determination of the length of jacket to be removed from the optical fiber.

  4. Ultrasonic inspection and deployment apparatus

    DOEpatents

    Michaels, Jennifer E.; Michaels, Thomas E.; Mech, Jr., Stephen J.

    1984-01-01

    An ultrasonic inspection apparatus for the inspection of metal structures, especially installed pipes. The apparatus combines a specimen inspection element, an acoustical velocity sensing element, and a surface profiling element, all in one scanning head. A scanning head bellows contains a volume of oil above the pipe surface, serving as acoustical couplant between the scanning head and the pipe. The scanning head is mounted on a scanning truck which is mobile around a circular track surrounding the pipe. The scanning truck has sufficient motors, gears, and position encoders to allow the scanning head six degrees of motion freedom. A computer system continually monitors acoustical velocity, and uses that parameter to process surface profiling and inspection data. The profiling data is used to automatically control scanning head position and alignment and to define a coordinate system used to identify and interpret inspection data. The apparatus is suitable for highly automated, remote application in hostile environments, particularly high temperature and radiation areas.

  5. NON-DESTRUCTIVE FLAW DETECTION APPARATUS

    DOEpatents

    Stateman, M.J.; Holloway, H.R.

    1957-12-17

    An apparatus is described for the non-destructive detection of flaws in electrical conducting articles. The particular feature of the detection apparatus is that a flaw in the front or back of the test article will not be masked by signals caused by the passage of the end and front of the article through the detection apparatus. The present invention alleviates the above problem by mounting detection coils on directly opposite sides of the test passageway so that the axes of the pickup coils are perpendicular to the axis of an energizing coil through which the article is passed. A flaw in the article will cause a change in the voltage induced in one pickup coil, but passage of the end or front of the article will not produce unequal signals. The signals are compared in appropriate electrical circuitry to actuate a recorder only when unequal signals are present, indicating the presence of a flaw.

  6. Prehensile apparatus

    DOEpatents

    Smith, C.M.

    1993-10-12

    The present invention relates to an apparatus for handling a workpiece comprising a vessel that is longitudinally extensible and pressurizable, and a nonextensible and laterally flexible member on the vessel. The member constrains one side of the vessel to be nonextensible, causing the vessel to bend in the direction of the nonextensible member when pressurized. 8 figures.

  7. Thermal protection apparatus

    DOEpatents

    Bennett, Gloria A.; Moore, Troy K.

    1988-01-01

    An apparatus for thermally protecting heat sensitive components of tools. The apparatus comprises a Dewar for holding the heat sensitive components. The Dewar has spaced-apart inside and outside walls, an open top end and a bottom end. An insulating plug is located in the top end. The inside wall has portions defining an inside wall aperture located at the bottom of the Dewar and the outside wall has portions defining an outside wall aperture located at the bottom of the Dewar. A bottom connector has inside and outside components. The inside component sealably engages the inside wall aperture and the outside component sealably engages the outside wall aperture. The inside component is operatively connected to the heat sensitive components and to the outside component. The connections can be made with optical fibers or with electrically conducting wires.

  8. 46 CFR 167.40-20 - Deep-sea sounding apparatus.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Deep-sea sounding apparatus. 167.40-20 Section 167.40-20... SHIPS Certain Equipment Requirements § 167.40-20 Deep-sea sounding apparatus. Nautical school ships shall be equipped with an efficient or electronic deep-sea sounding apparatus. The electronic deep-sea...

  9. 46 CFR 167.40-20 - Deep-sea sounding apparatus.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Deep-sea sounding apparatus. 167.40-20 Section 167.40-20... SHIPS Certain Equipment Requirements § 167.40-20 Deep-sea sounding apparatus. Nautical school ships shall be equipped with an efficient or electronic deep-sea sounding apparatus. The electronic deep-sea...

  10. 46 CFR 167.40-20 - Deep-sea sounding apparatus.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Deep-sea sounding apparatus. 167.40-20 Section 167.40-20... SHIPS Certain Equipment Requirements § 167.40-20 Deep-sea sounding apparatus. Nautical school ships shall be equipped with an efficient or electronic deep-sea sounding apparatus. The electronic deep-sea...

  11. 46 CFR 167.40-20 - Deep-sea sounding apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SHIPS Certain Equipment Requirements § 167.40-20 Deep-sea sounding apparatus. Nautical school ships shall be equipped with an efficient or electronic deep-sea sounding apparatus. The electronic deep-sea... 46 Shipping 7 2011-10-01 2011-10-01 false Deep-sea sounding apparatus. 167.40-20 Section 167.40-20...

  12. 21 CFR 864.5240 - Automated blood cell diluting apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated blood cell diluting apparatus. 864.5240... § 864.5240 Automated blood cell diluting apparatus. (a) Identification. An automated blood cell diluting apparatus is a fully automated or semi-automated device used to make appropriate dilutions of a blood sample...

  13. 21 CFR 864.5240 - Automated blood cell diluting apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Automated blood cell diluting apparatus. 864.5240... § 864.5240 Automated blood cell diluting apparatus. (a) Identification. An automated blood cell diluting apparatus is a fully automated or semi-automated device used to make appropriate dilutions of a blood sample...

  14. 46 CFR 167.40-20 - Deep-sea sounding apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SHIPS Certain Equipment Requirements § 167.40-20 Deep-sea sounding apparatus. Nautical school ships shall be equipped with an efficient or electronic deep-sea sounding apparatus. The electronic deep-sea... 46 Shipping 7 2010-10-01 2010-10-01 false Deep-sea sounding apparatus. 167.40-20 Section 167.40-20...

  15. Signaling Pathways of Purinergic Receptors and Their Interactions with Cholinergic and Adrenergic Pathways in the Lacrimal Gland

    PubMed Central

    Hodges, Robin R.

    2016-01-01

    Abstract Purpose: Purinergic receptors play a key role in the function of the lacrimal gland (LG) as P1 purinergic receptors A1, A2A, and A2B, P2X1–7 receptors, and many of the P2Y receptors are expressed. Methods: This review examines the current knowledge of purinergic receptors in the LG as well as the signaling pathways activated by these receptors. Results: These receptors are expressed on the acinar, ductal, and myoepithelial cells. Considerable crosstalk exists between the pathways activated by P2X7 receptors with those activated by M3 muscarinic or α1D adrenergic receptors. The mechanism of the crosstalk between P2X7 and M3 muscarinic receptors differs from that of the crosstalk between P2X7 and α1D adrenergic receptors. Conclusions: Understanding purinergic receptors and how they modulate protein secretion could play a key role in normal and pathological responses of the LG. PMID:27463365

  16. Rotary high power transfer apparatus

    NASA Technical Reports Server (NTRS)

    Jacobson, Peter E. (Inventor); Porter, Ryan S. (Inventor)

    1987-01-01

    An apparatus for reducing terminal-to-terminal circuit resistance and enhancing heat transfer in a rotary power transfer apparatus of the roll ring type comprising a connecting thimble for attaching an external power cable to a cone shaped terminal which is attached to a tab integral to an outer ring. An inner ring having a spherical recess mates with the spherical end of a tie connector. A cone shaped terminal is fitted to a second connecting thimble for attaching a second external power cable.

  17. Compact Apparatus Grows Protein Crystals

    NASA Technical Reports Server (NTRS)

    Bugg, Charles E.; Delucas, Lawrence J.; Suddath, Fred L.; Snyder, Robert S.; Herren, Blair J.; Carter, Daniel C.; Yost, Vaughn H.

    1989-01-01

    Laboratory apparatus provides delicately balanced combination of materials and chemical conditions for growth of protein crystals. Apparatus and technique for growth based on hanging-drop method for crystallization of macromolecules. Includes pair of syringes with ganged plungers. One syringe contains protein solution; other contains precipitating-agent solution. Syringes intrude into cavity lined with porous reservoir material saturated with 1 mL or more of similar precipitating-agent solution. Prior to activation, ends of syringes plugged to prevent transport of water vapor among three solutions.

  18. Apparatus for blending small particles

    DOEpatents

    Bradley, R.A.; Reese, C.R.; Sease, J.D.

    1975-08-26

    An apparatus is described for blending small particles and uniformly loading the blended particles in a receptacle. Measured volumes of various particles are simultaneously fed into a funnel to accomplish radial blending and then directed onto the apex of a conical splitter which collects the blended particles in a multiplicity of equal subvolumes. Thereafter the apparatus sequentially discharges the subvolumes for loading in a receptacle. A system for blending nuclear fuel particles and loading them into fuel rod molds is described in a preferred embodiment. (auth)

  19. Battery cell feedthrough apparatus

    DOEpatents

    Kaun, Thomas D.

    1995-01-01

    A compact, hermetic feedthrough apparatus comprising interfitting sleeve portions constructed of chemically-stable materials to permit unique battery designs and increase battery life and performance.

  20. 46 CFR 131.870 - Life floats and buoyant apparatus.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Life floats and buoyant apparatus. 131.870 Section 131... OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.870 Life floats and buoyant apparatus. (a) The name of the vessel must be plainly marked or painted on each life float or buoyant apparatus...

  1. 46 CFR 131.870 - Life floats and buoyant apparatus.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Life floats and buoyant apparatus. 131.870 Section 131... OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.870 Life floats and buoyant apparatus. (a) The name of the vessel must be plainly marked or painted on each life float or buoyant apparatus...

  2. 46 CFR 131.870 - Life floats and buoyant apparatus.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Life floats and buoyant apparatus. 131.870 Section 131... OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.870 Life floats and buoyant apparatus. (a) The name of the vessel must be plainly marked or painted on each life float or buoyant apparatus...

  3. 46 CFR 131.870 - Life floats and buoyant apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.870 Life floats and buoyant apparatus. (a) The name of the vessel must be plainly marked or painted on each life float or buoyant apparatus... 46 Shipping 4 2011-10-01 2011-10-01 false Life floats and buoyant apparatus. 131.870 Section 131...

  4. 46 CFR 160.010-6 - Capacity of buoyant apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Buoyant Apparatus for Merchant Vessels § 160.010... immersed or where facilities are provided for climbing on top of the apparatus. (2) Number of 300 mm (1 ft... 46 Shipping 6 2011-10-01 2011-10-01 false Capacity of buoyant apparatus. 160.010-6 Section 160.010...

  5. 46 CFR 160.010-6 - Capacity of buoyant apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Buoyant Apparatus for Merchant Vessels § 160.010... immersed or where facilities are provided for climbing on top of the apparatus. (2) Number of 300 mm (1 ft... 46 Shipping 6 2010-10-01 2010-10-01 false Capacity of buoyant apparatus. 160.010-6 Section 160.010...

  6. 46 CFR 131.870 - Life floats and buoyant apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.870 Life floats and buoyant apparatus. (a) The name of the vessel must be plainly marked or painted on each life float or buoyant apparatus... 46 Shipping 4 2010-10-01 2010-10-01 false Life floats and buoyant apparatus. 131.870 Section 131...

  7. Holographic Animation Apparatus.

    ERIC Educational Resources Information Center

    Johnston, Sean F.

    1979-01-01

    Describes a simple apparatus for producing strip holograms with a number of slit-shaped exposures displaced along the vertical direction. The hologram maintains full horizontal parallax, but the slit aperture reduces the vertical viewing angle of the animated object. (Author/GA)

  8. Hydrogen-Detection Apparatus

    NASA Technical Reports Server (NTRS)

    Ross, H. Richard; Bourgeois, Chris M.

    1995-01-01

    Apparatus continuously monitors concentration of hydrogen, at level ranging from few parts per million to several percent, in mixture of gases. Simple and fast, providing high sensitivity and linear response. Used to alert technicians to potentially explosive concentrations of residual hydrogen.

  9. Method of magnetic separation and apparatus therefore

    NASA Technical Reports Server (NTRS)

    Oder, Robin R. (Inventor)

    1991-01-01

    An apparatus for magnetically separating and collecting particulate matter fractions of a raw sample according to relative magnetic susceptibilities of each fraction so collected is disclosed. The separation apparatus includes a splitter which is used in conjunction with a magnetic separator for achieving the desired fractionation.

  10. Sealed-bladdered chemical processing method and apparatus

    DOEpatents

    Harless, D. Phillip

    1999-01-01

    A method and apparatus which enables a complete multi-stepped chemical treatment process to occur within a single, sealed-bladdered vessel 31. The entire chemical process occurs without interruption of the sealed-bladdered vessel 31 such as opening the sealed-bladdered vessel 31 between various steps of the process. The sealed-bladdered vessel 31 is loaded with a batch to be dissolved, treated, decanted, rinsed and/or dried. A pressure filtration step may also occur. The self-contained chemical processing apparatus 32 contains a sealed-bladder 32, a fluid pump 34, a reservoir 20, a compressed gas inlet, a vacuum pump 24, and a cold trap 23 as well as the associated piping 33, numerous valves 21,22,25,26,29,30,35,36 and other controls associated with such an apparatus. The claimed invention allows for dissolution and/or chemical treatment without the operator of the self-contained chemical processing apparatus 38 coming into contact with any of the process materials.

  11. THE INCIDENCE OF SYMPTOMATIC ACQUIRED LACRIMAL OUTFLOW OBSTRUCTION AMONG RESIDENTS OF OLMSTED COUNTY, MINNESOTA, 1976–2000 (AN AMERICAN OPHTHALMOLOGICAL SOCIETY THESIS)

    PubMed Central

    J., John; Woog

    2007-01-01

    Purpose To define the incidence, clinical characteristics, and outcomes following treatment of symptomatic acquired lacrimal outflow obstruction (SALOO) in Olmsted County, Minnesota, from 1976 to 2000, and to test the hypothesis that the incidence of this disorder increased over this interval. Methods In this retrospective, population-based study, the Rochester Epidemiology Project was used to identify patients above the age of 5 years with SALOO. Patient medical records were reviewed, and the incidence and localization of lacrimal obstruction were determined. Results Five-hundred eighty-seven patients with SALOO were identified, with an average annual incidence rate of 30.47 per 100,000. Nasolacrimal duct obstruction was most common, with an incidence of 20.24 per 100,000. The increase in incidence from 1976–1979 to 1996–2000 was statistically significant (P=.01). Among 397 patients with nasolacrimal duct obstruction, 107 (27%) were male and 290 (73%) female, with a mean age of 59.5 ± 22 years. SALOO and nasolacrimal duct obstruction incidence increased with age. Glaucoma, dry eye, cataract, diabetes mellitus, systemic malignancy, cigarette smoking, and hypertension were noted in 5.5%, 8.7%, 37.5%, 10.9%, 18.5%, 26.4%, and 41.1% of patients, respectively. One hundred eleven patients underwent dacryocystorhinostomy, with a success rate of 94.1%. Conclusions SALOO incidence increased during the study interval, although a possible plateau effect was noted during the last 5 years of the study period. The majority of patients were female above the age of 66 years. The latter finding, in conjunction with US demographic trends, suggests that the frequency of SALOO may continue to increase in the future. External dacryocystorhinostomy appeared to be effective in the management of nasolacrimal duct obstruction. PMID:18427633

  12. Superconducting magnetic shielding apparatus and method

    DOEpatents

    Clem, John R.; Clem, John R.

    1983-01-01

    Disclosed is a method and apparatus for providing magnetic shielding around a working volume. The apparatus includes a hollow elongated superconducting shell or cylinder having an elongated low magnetic pinning central portion, and two high magnetic pinning end regions. Transition portions of varying magnetic pinning properties are interposed between the central and end portions. The apparatus further includes a solenoid substantially coextensive with and overlying the superconducting cylinder, so as to be magnetically coupled therewith. The method includes the steps passing a longitudinally directed current through the superconducting cylinder so as to depin magnetic reservoirs trapped in the cylinder. Next, a circumferentially directed current is passed through the cylinder, while a longitudinally directed current is maintained. Depinned magnetic reservoirs are moved to the end portions of the cylinder, where they are trapped.

  13. Superconducting magnetic shielding apparatus and method

    DOEpatents

    Clem, J.R.; Clem, J.R.

    1983-10-11

    Disclosed are a method and apparatus for providing magnetic shielding around a working volume. The apparatus includes a hollow elongated superconducting shell or cylinder having an elongated low magnetic pinning central portion, and two high magnetic pinning end regions. Transition portions of varying magnetic pinning properties are interposed between the central and end portions. The apparatus further includes a solenoid substantially coextensive with and overlying the superconducting cylinder, so as to be magnetically coupled therewith. The method includes the steps passing a longitudinally directed current through the superconducting cylinder so as to depin magnetic reservoirs trapped in the cylinder. Next, a circumferentially directed current is passed through the cylinder, while a longitudinally directed current is maintained. Depinned magnetic reservoirs are moved to the end portions of the cylinder, where they are trapped. 5 figs.

  14. Superconducting magnetic shielding apparatus and method

    DOEpatents

    Clem, J.R.

    1982-07-09

    Disclosed is a method and apparatus for providing magnetic shielding around a working volume. The apparatus includes a hollow elongated superconducting shell or cylinder having an elongated low magnetic pinning central portion, and two high magnetic pinning end regions. Transition portions of varying magnetic pinning properties are interposed between the central and end portions. The apparatus further includes a solenoid substantially coextensive with and overlying the superconducting cylinder, so as to be magnetically coupled therewith. The method includes the steps passing a longitudinally directed current through the superconducting cylinder so as to depin magnetic reservoirs trapped in the cylinder. Next, a circumferentially directed current is passed through the cylinder, while a longitudinally directed current is maintained. Depinned magnetic reservoirs are moved to the end portions of the cylinder, where they are trapped.

  15. Evaluation of Lacrimation Characteristics in Clinically Normal New Zealand White Rabbits by Using the Schirmer Tear Test I

    PubMed Central

    Whittaker, Alexandra L; Williams, David L

    2015-01-01

    Rabbits are a common animal model in eye research and in safety testing of novel chemical agents. In addition, ocular disease is a routine presentation in clinical practice. However, few studies have quantitatively examined lacrimation kinetics in this species. This study used a noninvasive method of tear measurement (the Schirmer tear test, STT) to quantify values for basal and reflex tearing and to determine the kinetic nature of tear production in 76 New Zealand white rabbits. We obtained a value of 7.58 ± 2.3 mm/min for the standard 1-min STT. Calculated values for mean residual tear volume and reflex tear flow were 1.95 µL and 0.035 µL/s, respectively. In addition, this study provides preliminary evidence for an interaction effect between eyes given that higher STT values were obtained from the second eye tested. PMID:26632789

  16. Microscope collision protection apparatus

    DOEpatents

    DeNure, Charles R.

    2001-10-23

    A microscope collision protection apparatus for a remote control microscope which protects the optical and associated components from damage in the event of an uncontrolled collision with a specimen, regardless of the specimen size or shape. In a preferred embodiment, the apparatus includes a counterbalanced slide for mounting the microscope's optical components. This slide replaces the rigid mounts on conventional upright microscopes with a precision ball bearing slide. As the specimen contacts an optical component, the contacting force will move the slide and the optical components mounted thereon. This movement will protect the optical and associated components from damage as the movement causes a limit switch to be actuated, thereby stopping all motors responsible for the collision.

  17. Fissile solution measurement apparatus

    DOEpatents

    Crane, T.W.; Collinsworth, P.R.

    1984-06-11

    An apparatus for determining the content of a fissile material within a solution by detecting delayed fission neutrons emitted by the fissile material after it is temporarily irradiated by a neutron source. The apparatus comprises a container holding the solution and having a portion defining a neutron source cavity centrally disposed within the container. The neutron source cavity temporarily receives the neutron source. The container has portions defining a plurality of neutron detector ports that form an annular pattern and surround the neutron source cavity. A plurality of neutron detectors count delayed fission neutrons emitted by the fissile material. Each neutron detector is located in a separate one of the neutron detector ports.

  18. Apparatus enables automatic microanalysis of body fluids

    NASA Technical Reports Server (NTRS)

    Soffen, G. A.; Stuart, J. L.

    1966-01-01

    Apparatus will automatically and quantitatively determine body fluid constituents which are amenable to analysis by fluorometry or colorimetry. The results of the tests are displayed as percentages of full scale deflection on a strip-chart recorder. The apparatus can also be adapted for microanalysis of various other fluids.

  19. Sensor apparatus

    DOEpatents

    Deason, Vance A [Idaho Falls, ID; Telschow, Kenneth L [Idaho Falls, ID

    2009-12-22

    A sensor apparatus and method for detecting an environmental factor is shown that includes an acoustic device that has a characteristic resonant vibrational frequency and mode pattern when exposed to a source of acoustic energy and, futher, when exposed to an environmental factor, produces a different resonant vibrational frequency and/or mode pattern when exposed to the same source of acoustic energy.

  20. Pole pulling apparatus and method

    DOEpatents

    McIntire, Gary L.

    1989-01-01

    An apparatus for removal of embedded utility-type poles which removes the poles quickly and efficiently from their embedded position without damage to the pole or surrounding structures. The apparatus includes at least 2 piston/cylinder members equally spaced about the pole, and a head member affixed to the top of each piston. Elongation of the piston induces rotation of the head into the pole to increase the gripping action and reduce slippage. Repeated actuation and retraction of the piston and head member will "jack" the pole from its embedded position.

  1. Apparatus for controlling fluidized beds

    DOEpatents

    Rehmat, A.G.; Patel, J.G.

    1987-05-12

    An apparatus and process are disclosed for control and maintenance of fluidized beds under non-steady state conditions. An ash removal conduit is provided for removing solid particulates from a fluidized bed separate from an ash discharge conduit in the lower portion of the grate supporting such a bed. The apparatus and process of this invention is particularly suitable for use in ash agglomerating fluidized beds and provides control of the fluidized bed before ash agglomeration is initiated and during upset conditions resulting in stable, sinter-free fluidized bed maintenance. 2 figs.

  2. Apparatus for controlling fluidized beds

    DOEpatents

    Rehmat, Amirali G.; Patel, Jitendra G.

    1987-05-12

    An apparatus and process for control and maintenance of fluidized beds under non-steady state conditions. An ash removal conduit is provided for removing solid particulates from a fluidized bed separate from an ash discharge conduit in the lower portion of the grate supporting such a bed. The apparatus and process of this invention is particularly suitable for use in ash agglomerating fluidized beds and provides control of the fluidized bed before ash agglomeration is initiated and during upset conditions resulting in stable, sinter-free fluidized bed maintenance.

  3. Sample introducing apparatus and sample modules for mass spectrometer

    DOEpatents

    Thompson, Cyril V.; Wise, Marcus B.

    1993-01-01

    An apparatus for introducing gaseous samples from a wide range of environmental matrices into a mass spectrometer for analysis of the samples is described. Several sample preparing modules including a real-time air monitoring module, a soil/liquid purge module, and a thermal desorption module are individually and rapidly attachable to the sample introducing apparatus for supplying gaseous samples to the mass spectrometer. The sample-introducing apparatus uses a capillary column for conveying the gaseous samples into the mass spectrometer and is provided with an open/split interface in communication with the capillary and a sample archiving port through which at least about 90 percent of the gaseous sample in a mixture with an inert gas that was introduced into the sample introducing apparatus is separated from a minor portion of the mixture entering the capillary discharged from the sample introducing apparatus.

  4. Apparatus for coating and impregnating filament with resin

    DOEpatents

    Robinson, S.C.; Pollard, R.E.

    1986-12-17

    The present invention is directed to an apparatus for evenly coating and impregnating a filament with binder material. Dimension control and repeatability of the coating and impregnating characteristics are obtained with the apparatus.

  5. Radioactive waste processing apparatus

    DOEpatents

    Nelson, Robert E.; Ziegler, Anton A.; Serino, David F.; Basnar, Paul J.

    1987-01-01

    Apparatus for use in processing radioactive waste materials for shipment and storage in solid form in a container is disclosed. The container includes a top, and an opening in the top which is smaller than the outer circumference of the container. The apparatus includes an enclosure into which the container is placed, solution feed apparatus for adding a solution containing radioactive waste materials into the container through the container opening, and at least one rotatable blade for blending the solution with a fixing agent such as cement or the like as the solution is added into the container. The blade is constructed so that it can pass through the opening in the top of the container. The rotational axis of the blade is displaced from the center of the blade so that after the blade passes through the opening, the blade and container can be adjusted so that one edge of the blade is adjacent the cylindrical wall of the container, to insure thorough mixing. When the blade is inside the container, a substantially sealed chamber is formed to contain vapors created by the chemical action of the waste solution and fixant, and vapors emanating through the opening in the container.

  6. Effect of rebamipide ophthalmic suspension on the success of lacrimal stent intubation.

    PubMed

    Mimura, Masashi; Ueki, Mari; Oku, Hidehiro; Sato, Bunpei; Ikeda, Tsunehiko

    2016-02-01

    To evaluate the effect of the postoperative administration of rebamipide ophthalmic suspension on the success rate of lacrimal stent intubation (LSI) for the treatment of primary acquired nasolacrimal duct obstruction (PANDO). This comparative interventional cohort study investigated 110 consecutive patients with PANDO who were treated with LSI and followed up for 12 months postoperatively at one institution. LSI was performed by one surgeon, and all patients received identical postoperative care. Among the total 110 patients, 71 underwent LSI with postoperative administration of rebamipide ophthalmic suspension, and 39 underwent LSI without administration of the suspension. Data related to patient age, gender, laterality, and postoperative administration of rebamipide ophthalmic suspension were collected and used as independent variables, and logistic regression analyses were performed to compare the anatomical success rate at 12 months postoperatively between patients with and without postoperative administration of the suspension. The anatomical success rate of LSI in patients with and without postoperative administration of rebamipide ophthalmic suspension was 90.1 and 69.2 %, respectively. A comparison of these success rates showed statistical significance, in that the rate of treatment success was higher in PANDO patients who underwent LSI with postoperative administration of the suspension [odds ratio (OR), 3.37; P < 0.05]. The findings of this study show that postoperative administration of rebamipide ophthalmic suspension increases the rate of anatomical success in patients who undergo LSI for the treatment of PANDO.

  7. 49 CFR 234.205 - Operating characteristics of warning system apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... apparatus. 234.205 Section 234.205 Transportation Other Regulations Relating to Transportation (Continued... characteristics of warning system apparatus. Operating characteristics of electromagnetic, electronic, or electrical apparatus of each highway-rail crossing warning system shall be maintained in accordance with the...

  8. 49 CFR 234.205 - Operating characteristics of warning system apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... apparatus. 234.205 Section 234.205 Transportation Other Regulations Relating to Transportation (Continued... characteristics of warning system apparatus. Operating characteristics of electromagnetic, electronic, or electrical apparatus of each highway-rail crossing warning system shall be maintained in accordance with the...

  9. Tadpole-shaped lateralized parietal atretic cephalocele associated with an ipsilateral lacrimal gland fistula and schizencephalic clefts.

    PubMed

    Murakami, Nobuya; Morioka, Takato; Suzuki, Satoshi O; Mukae, Nobutaka; Hashiguchi, Kimiaki; Iihara, Koji

    2017-02-01

    Parietal atretic cephalocele (AC) and its associated intracranial venous anomalies, such as vertical embryonic positioning of the straight sinus (VEP of SS), have, in previous reports, been exclusively restricted to the midline. We report a patient with lateralized parietal AC on the right side. The AC was in the shape of a tadpole, with a large head and a long tail, extending to the proximity of the right external canthus, where a lacrimal gland fistula was observed. The superior sagittal sinus and VEP of SS were also displaced to the right side, although the sagittal suture was located at the midline. Schizencephalic clefts in the right posterior cortex were also observed. The parietal AC, which was initially located in the midline, could conceivably have been displaced to the right side by other developmental processes. However, the relationship between lateralized AC and associated multiple anomalies on the ipsilateral side is difficult to explain monogenetically. Our case study indicates that AC might have a broader spectrum of clinical symptoms than was once thought to be the case.

  10. Apparatus Tests Thermocouples For Seebeck Inhomogeneity

    NASA Technical Reports Server (NTRS)

    Burkett, Cecil G., Jr.; Bauserman, Willard A., Jr.; West, James W.

    1995-01-01

    Automated apparatus reveals sources of error not revealed in calibration. Computer-controlled apparatus detects and measures Seebeck inhomogeneities in sheathed thermocouples. Measures thermocouple output voltage as function of position of probe along sharp gradient of temperature. Abnormal variations in voltage-versus-position data indicative of Seebeck inhomogeneities. Prototype for development of standard method and equipment for routine acceptance/rejection testing of sheathed thermocouples in industrial and research laboratories.

  11. Method and apparatus for measuring stress

    DOEpatents

    Thompson, R.B.

    1983-07-28

    A method and apparatus for determining stress in a material independent of micro-structural variations and anisotropies. The method comprises comparing the velocities of two horizontally polarized and horizontally propagating ultrasonic shear waves with interchanged directions of propagation and polarization. The apparatus for carrying out the method comprises periodic permanent magnet-electromagnetic acoustic transducers for generating and detecting the shear waves and means for determining the wave velocities.

  12. Method and apparatus for measuring stress

    DOEpatents

    Thompson, R. Bruce

    1985-06-11

    A method and apparatus for determining stress in a material independent of micro-structural variations and anisotropies. The method comprises comparing the velocities of two horizontally polarized and horizontally propagating ultrasonic shear waves with interchanged directions of propagation and polarization. The apparatus for carrying out the method comprises periodic permanent magnet-electromagnetic acoustic transducers for generating and detecting the shear waves and means for determining the wave velocities.

  13. Apparatus Named after Our Academic Ancestors, III

    ERIC Educational Resources Information Center

    Greenslade, Thomas B., Jr.

    2014-01-01

    My academic ancestors in physics have called on me once more to tell you about the apparatus that they devised, and that many of you have used in your demonstrations and labs. This article is about apparatus named after François Arago, Heinrich Helmholtz, Leon Foucault, and James Watt.

  14. Apparatus and method for gelling liquefied gasses

    NASA Technical Reports Server (NTRS)

    Elliott, Adam (Inventor); DiSalvo, Roberto (Inventor); Shepherd, Phillip (Inventor); Kosier, Ryan (Inventor)

    2011-01-01

    A method and apparatus for gelling liquid propane and other liquefied gasses includes a temperature controlled churn mixer, vacuum pump, liquefied gas transfer tank, and means for measuring amount of material entering the mixer. The apparatus and method are particularly useful for the production of high quality rocket fuels and propellants.

  15. Battery cell feedthrough apparatus

    DOEpatents

    Kaun, T.D.

    1995-03-14

    A compact, hermetic feedthrough apparatus is described comprising interfitting sleeve portions constructed of chemically-stable materials to permit unique battery designs and increase battery life and performance. 8 figs.

  16. 30 CFR 7.406 - Flame test apparatus.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Cable Splice Kits § 7.406 Flame test apparatus. The principal parts of the apparatus used to test for... extend to the sample end location. These are used to energize the electric cable and splice specimens. They are not used, but may stay in place, when testing signaling cables. (b) Specimen holder (support...

  17. 30 CFR 7.406 - Flame test apparatus.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Cable Splice Kits § 7.406 Flame test apparatus. The principal parts of the apparatus used to test for... extend to the sample end location. These are used to energize the electric cable and splice specimens. They are not used, but may stay in place, when testing signaling cables. (b) Specimen holder (support...

  18. 30 CFR 7.406 - Flame test apparatus.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Cable Splice Kits § 7.406 Flame test apparatus. The principal parts of the apparatus used to test for... extend to the sample end location. These are used to energize the electric cable and splice specimens. They are not used, but may stay in place, when testing signaling cables. (b) Specimen holder (support...

  19. Remotely actuated localized pressure and heat apparatus and method of use

    NASA Technical Reports Server (NTRS)

    Merret, John B. (Inventor); Taylor, DeVor R. (Inventor); Wheeler, Mark M. (Inventor); Gale, Dan R. (Inventor)

    2004-01-01

    Apparatus and method for the use of a remotely actuated localized pressure and heat apparatus for the consolidation and curing of fiber elements in, structures. The apparatus includes members for clamping the desired portion of the fiber elements to be joined, pressure members and/or heat members. The method is directed to the application and use of the apparatus.

  20. 21 CFR 878.4680 - Nonpowered, single patient, portable suction apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... apparatus. 878.4680 Section 878.4680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND....4680 Nonpowered, single patient, portable suction apparatus. (a) Identification. A nonpowered, single patient, portable suction apparatus is a device that consists of a manually operated plastic, disposable...

  1. 21 CFR 878.4680 - Nonpowered, single patient, portable suction apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... apparatus. 878.4680 Section 878.4680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND....4680 Nonpowered, single patient, portable suction apparatus. (a) Identification. A nonpowered, single patient, portable suction apparatus is a device that consists of a manually operated plastic, disposable...

  2. Sample introducing apparatus and sample modules for mass spectrometer

    DOEpatents

    Thompson, C.V.; Wise, M.B.

    1993-12-21

    An apparatus for introducing gaseous samples from a wide range of environmental matrices into a mass spectrometer for analysis of the samples is described. Several sample preparing modules including a real-time air monitoring module, a soil/liquid purge module, and a thermal desorption module are individually and rapidly attachable to the sample introducing apparatus for supplying gaseous samples to the mass spectrometer. The sample-introducing apparatus uses a capillary column for conveying the gaseous samples into the mass spectrometer and is provided with an open/split interface in communication with the capillary and a sample archiving port through which at least about 90 percent of the gaseous sample in a mixture with an inert gas that was introduced into the sample introducing apparatus is separated from a minor portion of the mixture entering the capillary discharged from the sample introducing apparatus. 5 figures.

  3. Mechanically-reattachable liquid-cooled cooling apparatus

    DOEpatents

    Arney, Susanne; Cheng, Jen-Hau; Kolodner, Paul R; Kota-Venkata, Krishna-Murty; Scofield, William; Salamon, Todd R; Simon, Maria E

    2013-09-24

    An apparatus comprising a rack having a row of shelves, each shelf supporting an electronics circuit board, each one of the circuit boards being manually removable from the shelve supporting the one of the circuit boards and having a local heat source thereon. The apparatus also comprises a cooler attached to the rack and being able to circulate a cooling fluid around a channel forming a closed loop. The apparatus further comprises a plurality of heat conduits, each heat conduit being located over a corresponding one of the circuit boards and forming a path to transport heat from the local heat source of the corresponding one of the circuit boards to the cooler. Each heat conduit is configured to be manually detachable from the cooler or the circuit board, without breaking a circulation pathway of the fluid through the cooler.

  4. Method and apparatus for inspecting conduits

    DOEpatents

    Spisak, Michael J.; Nance, Roy A.

    1997-01-01

    An apparatus and method for ultrasonic inspection of a conduit are provided. The method involves directing a first ultrasonic pulse at a particular area of the conduit at a first angle, receiving the reflected sound from the first ultrasonic pulse, substantially simultaneously or subsequently in very close time proximity directing a second ultrasonic pulse at said area of the conduit from a substantially different angle than said first angle, receiving the reflected sound from the second ultrasonic pulse, and comparing the received sounds to determine if there is a defect in that area of the conduit. The apparatus of the invention is suitable for carrying out the above-described method. The method and apparatus of the present invention provide the ability to distinguish between sounds reflected by defects in a conduit and sounds reflected by harmless deposits associated with the conduit.

  5. Apparatus bias and place conditioning with ethanol in mice.

    PubMed

    Cunningham, Christopher L; Ferree, Nikole K; Howard, MacKenzie A

    2003-12-01

    Although the distinction between "biased" and "unbiased" is generally recognized as an important methodological issue in place conditioning, previous studies have not adequately addressed the distinction between a biased/unbiased apparatus and a biased/unbiased stimulus assignment procedure. Moreover, a review of the recent literature indicates that many reports (70% of 76 papers published in 2001) fail to provide adequate information about apparatus bias. This issue is important because the mechanisms underlying a drug's effect in the place-conditioning procedure may differ depending on whether the apparatus is biased or unbiased. The present studies were designed to assess the impact of apparatus bias and stimulus assignment procedure on ethanol-induced place conditioning in mice (DBA/2 J). A secondary goal was to compare various dependent variables commonly used to index conditioned place preference. Apparatus bias was manipulated by varying the combination of tactile (floor) cues available during preference tests. Experiment 1 used an unbiased apparatus in which the stimulus alternatives were equally preferred during a pre-test as indicated by the group average. Experiment 2 used a biased apparatus in which one of the stimuli was strongly preferred by most mice (mean % time on cue = 67%) during the pre-test. In both studies, the stimulus paired with drug (CS+) was assigned randomly (i.e., an "unbiased" stimulus assignment procedure). Experimental mice received four pairings of CS+ with ethanol (2 g/kg, i.p.) and four pairings of the alternative stimulus (CS-) with saline; control mice received saline on both types of trial. Each experiment concluded with a 60-min choice test. With the unbiased apparatus (experiment 1), significant place conditioning was obtained regardless of whether drug was paired with the subject's initially preferred or non-preferred stimulus. However, with the biased apparatus (experiment 2), place conditioning was apparent only when

  6. Cherry-Slush-Candling Apparatus

    NASA Technical Reports Server (NTRS)

    Stephens, James B.; Weiss, James R.; Hoover, Gordon

    1996-01-01

    Proposed infrared-scanning apparatus for use in bakeries making cherry pies detect cherry pits remaining in cherry slush after pitting process. Pits detected via their relative opacity to infrared radiation.

  7. Apparatus for measuring high frequency currents

    NASA Technical Reports Server (NTRS)

    Hagmann, Mark J. (Inventor); Sutton, John F. (Inventor)

    2003-01-01

    An apparatus for measuring high frequency currents includes a non-ferrous core current probe that is coupled to a wide-band transimpedance amplifier. The current probe has a secondary winding with a winding resistance that is substantially smaller than the reactance of the winding. The sensitivity of the current probe is substantially flat over a wide band of frequencies. The apparatus is particularly useful for measuring exposure of humans to radio frequency currents.

  8. Centrifuge apparatus

    DOEpatents

    Sartory, Walter K.; Eveleigh, John W.

    1976-01-01

    A method and apparatus for operating a continuous flow blood separation centrifuge are provided. The hematocrit of the entrant whole blood is continuously maintained at an optimum constant value by the addition of plasma to the entrant blood. The hematocrit of the separated red cells is monitored to indicate the degree of separation taking place, thereby providing a basis for regulating the flow through the centrifuge.

  9. 21 CFR 888.5850 - Nonpowered orthopedic traction apparatus and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nonpowered orthopedic traction apparatus and accessories. 888.5850 Section 888.5850 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... orthopedic traction apparatus and accessories. (a) Identification. A nonpowered orthopedic traction apparatus...

  10. 21 CFR 888.5850 - Nonpowered orthopedic traction apparatus and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nonpowered orthopedic traction apparatus and accessories. 888.5850 Section 888.5850 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... orthopedic traction apparatus and accessories. (a) Identification. A nonpowered orthopedic traction apparatus...

  11. Ophthalmic method and apparatus

    NASA Technical Reports Server (NTRS)

    Evvard, J. C.; Mcgannon, W. J.; Vargo, D. J. (Inventor)

    1973-01-01

    A method and apparatus for removing material and components such as the lens from an eye is described. High speed rotary cutting members at one end of a rod macerate the lens while an annular tubing disposed around the cutting members vibrates ultrasonically to coact with the cutting members in macerating the lens. At the same time, a liquid is supplied to the chamber behind the cornea of the eye. Spiral grooves extending along the rotating rod from the cutting members evacuate the liquid and the macerated material from the eye. An alternate embodiment of the apparatus includes a tube through which liquid is supplied to the operative site of the ultrasonically vibrating tube and the cutting members in the area of the lens.

  12. Electrowinning apparatus and process

    DOEpatents

    Buschmann, Wayne E [Boulder, CO

    2012-06-19

    Apparatus and processes are disclosed for electrowinning metal from a fluid stream. A representative apparatus comprises at least one spouted bed reactor wherein each said reactor includes an anolyte chamber comprising an anode and configured for containing an anolyte, a catholyte chamber comprising a current collector and configured for containing a particulate cathode bed and a flowing stream of an electrically conductive metal-containing fluid, and a membrane separating said anolyte chamber and said catholyte chamber, an inlet for an electrically conductive metal-containing fluid stream; and a particle bed churning device configured for spouting particle bed particles in the catholyte chamber independently of the flow of said metal-containing fluid stream. In operation, reduced heavy metals or their oxides are recovered from the cathode particles.

  13. Drum tie-down apparatus

    DOEpatents

    Morse, H.E.

    A drum tie-down apparatus for securing drum-like containers in an upright position to a floor or platform of a transportation vehicle having spaced apart cargo tie-down points. The apparatus comprises a pair of cylindrical, hollow tube segments horizontally oriented and engageable with a drum lid adjacent opposite rim edges, flexible strap segments for connecting upper and lower central portions of the tube segments together across the drum lid and a pair of elongated flexible tie-down segments, one extending horizontally through each of the tube segments, the ends thereof being attached to said spaced apart tie-down points such that end portions of the pair of tie-down segments extend downwardly and radially outwardly from the tube segments to the tie-down points.

  14. Drum tie-down apparatus

    DOEpatents

    Morse, Harvey E.

    1984-01-01

    A drum tie-down apparatus for securing drum-like containers in an upright position to a floor or platform of a transportation vehicle having spaced apart cargo tie-down points. The apparatus comprises a pair of cylindrical, hollow tube segments horizontally oriented and engageable with a drum lid adjacent opposite rim edges, flexible strap segments for connecting upper and lower central portions of the tube segments together across the drum lid and a pair of elongated flexible tie-down segments, one extending horizontally through each of the tube segments, the ends thereof being attached to said spaced apart tie-down points such that end portions of the pair of tie-down segments extend downwardly and radially outwardly from the tube segments to the tie-down points.

  15. X-Ray Diffraction Apparatus

    NASA Technical Reports Server (NTRS)

    Blake, David F. (Inventor); Bryson, Charles (Inventor); Freund, Friedmann (Inventor)

    1996-01-01

    An x-ray diffraction apparatus for use in analyzing the x-ray diffraction pattern of a sample is introduced. The apparatus includes a beam source for generating a collimated x-ray beam having one or more discrete x-ray energies, a holder for holding the sample to be analyzed in the path of the beam, and a charge-coupled device having an array of pixels for detecting, in one or more selected photon energy ranges, x-ray diffraction photons produced by irradiating such a sample with said beam. The CCD is coupled to an output unit which receives input information relating to the energies of photons striking each pixel in the CCD, and constructs the diffraction pattern of photons within a selected energy range striking the CCD.

  16. Resonant-cavity apparatus for cytometry or particle analysis

    DOEpatents

    Gourley, P.L.

    1998-08-11

    A resonant-cavity apparatus for cytometry or particle analysis is described. The apparatus comprises a resonant optical cavity having an analysis region within the cavity for containing one or more biological cells or dielectric particles to be analyzed. In the presence of a cell or particle, a light beam in the form of spontaneous emission or lasing is generated within the resonant optical cavity and is encoded with information about the cell or particle. An analysis means including a spectrometer and/or a pulse-height analyzer is provided within the apparatus for recovery of the information from the light beam to determine a size, shape, identification or other characteristics about the cells or particles being analyzed. The recovered information can be grouped in a multi-dimensional coordinate space for identification of particular types of cells or particles. In some embodiments of the apparatus, the resonant optical cavity can be formed, at least in part, from a vertical-cavity surface-emitting laser. The apparatus and method are particularly suited to the analysis of biological cells, including blood cells, and can further include processing means for manipulating, sorting, or eradicating cells after analysis. 35 figs.

  17. Resonant-cavity apparatus for cytometry or particle analysis

    DOEpatents

    Gourley, Paul L.

    1998-01-01

    A resonant-cavity apparatus for cytometry or particle analysis. The apparatus comprises a resonant optical cavity having an analysis region within the cavity for containing one or more biological cells or dielectric particles to be analyzed. In the presence of a cell or particle, a light beam in the form of spontaneous emission or lasing is generated within the resonant optical cavity and is encoded with information about the cell or particle. An analysis means including a spectrometer and/or a pulse-height analyzer is provided within the apparatus for recovery of the information from the light beam to determine a size, shape, identification or other characteristics about the cells or particles being analyzed. The recovered information can be grouped in a multi-dimensional coordinate space for identification of particular types of cells or particles. In some embodiments of the apparatus, the resonant optical cavity can be formed, at least in part, from a vertical-cavity surface-emitting laser. The apparatus and method are particularly suited to the analysis of biological cells, including blood cells, and can further include processing means for manipulating, sorting, or eradicating cells after analysis thereof.

  18. Pulse combusted acoustic agglomeration apparatus and process

    DOEpatents

    Mansour, Momtaz N.; Chandran, Ravi

    1994-01-01

    An improved apparatus and process for removal of particulates entrained in a gas stream are provided. The removal process employs a pulse combustor to provide an acoustic pressure wave to acoustically enhance agglomeration of particulates which may be collected and removed using a conventional separation apparatus. The apparatus may be employed as a direct fired system for improved operation of gas-operated equipment such as a gas turbine, or may, alternatively, be employed as an add-on subsystem for combustion exhaust clean-up. Additionally, added particulates may include a sorbent for effecting sorption of other contaminants such as sulfur. Various other particulates for contaminant removal may also be introduced into the system as exemplified by alkali-gettering agents.

  19. Method and system for diagnostics of apparatus

    NASA Technical Reports Server (NTRS)

    Gorinevsky, Dimitry (Inventor)

    2012-01-01

    Proposed is a method, implemented in software, for estimating fault state of an apparatus outfitted with sensors. At each execution period the method processes sensor data from the apparatus to obtain a set of parity parameters, which are further used for estimating fault state. The estimation method formulates a convex optimization problem for each fault hypothesis and employs a convex solver to compute fault parameter estimates and fault likelihoods for each fault hypothesis. The highest likelihoods and corresponding parameter estimates are transmitted to a display device or an automated decision and control system. The obtained accurate estimate of fault state can be used to improve safety, performance, or maintenance processes for the apparatus.

  20. Sodium purification apparatus and method

    DOEpatents

    Gould, M.I.

    1980-03-04

    An apparatus for and method of collecting and storing oxide impurities contained in high-temperature liquid alkali metal are disclosed. A method and apparatus are provided for nucleating and precipitating oxide impurities by cooling, wherein the nucleation and precipitation are enhanced by causing a substantial increase in pressure drop and corresponding change in the velocity head of the alkali metal. Thereafter the liquid alkali metal is introduced into a quiescent zone wherein the liquid velocity is maintained below a specific maximum whereby it is possible to obtain high oxide removal efficiencies without the necessity of a mesh or filter. 1 fig.

  1. Sodium purification apparatus and method

    DOEpatents

    Gould, Marc I. [Van Nuys, CA

    1980-03-04

    An apparatus for and method of collecting and storing oxide impurities contained in high-temperature liquid alkali metal. A method and apparatus are provided for nucleating and precipitating oxide impurities by cooling, wherein the nucleation and precipitation are enhanced by causing a substantial increase in pressure drop and corresponding change in the velocity head of the alkali metal. Thereafter the liquid alkali metal is introduced into a quiescent zone wherein the liquid velocity is maintained below a specific maximum whereby it is possible to obtain high oxide removal efficiencies without the necessity of a mesh or filter.

  2. Dual rotating shaft seal apparatus

    DOEpatents

    Griggs, J.E.; Newman, H.J.

    1983-06-16

    The report is directed to apparatus suitable for transferring torque and rotary motion through a wall in a manner which is essentially gas impermeable. The apparatus can be used for pressurizing, agitating, and mixing fluids and features two ferrofluidic, i.e., ferrometic seals. Each seal is disposed on one of two supported shafts and each shaft is operably connected at one end to a gear mechanism and at its other end to an adjustable coupling means which is to be connected to a rotatable shaft extending through a wall through which torque and rotary motion are to be transferred.

  3. 27 CFR 29.55 - Registry of stills and distilling apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... distilling apparatus. 29.55 Section 29.55 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND... Registry of stills and distilling apparatus. (a) General. Every person having possession, custody, or control of any still or distilling apparatus set up shall, immediately on its being set up, register the...

  4. 27 CFR 29.55 - Registry of stills and distilling apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... distilling apparatus. 29.55 Section 29.55 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND... Registry of stills and distilling apparatus. (a) General. Every person having possession, custody, or control of any still or distilling apparatus set up shall, immediately on its being set up, register the...

  5. Advanced particulate matter control apparatus and methods

    DOEpatents

    Miller, Stanley J [Grand Forks, ND; Zhuang, Ye [Grand Forks, ND; Almlie, Jay C [East Grand Forks, MN

    2012-01-10

    Apparatus and methods for collection and removal of particulate matter, including fine particulate matter, from a gas stream, comprising a unique combination of high collection efficiency and ultralow pressure drop across the filter. The apparatus and method utilize simultaneous electrostatic precipitation and membrane filtration of a particular pore size, wherein electrostatic collection and filtration occur on the same surface.

  6. Method and apparatus for PM filter regeneration

    DOEpatents

    Opris, Cornelius N [Peoria, IL; Verkiel, Maarten [Metamora, IL

    2006-01-03

    A method and apparatus for initiating regeneration of a particulate matter (PM) filter in an exhaust system in an internal combustion engine. The method and apparatus includes determining a change in pressure of exhaust gases passing through the PM filter, and responsively varying an opening of an intake valve in fluid communication with a combustion chamber.

  7. Apparatus for automated testing of biological specimens

    DOEpatents

    Layne, Scott P.; Beugelsdijk, Tony J.

    1999-01-01

    An apparatus for performing automated testing of infections biological specimens is disclosed. The apparatus comprise a process controller for translating user commands into test instrument suite commands, and a test instrument suite comprising a means to treat the specimen to manifest an observable result, and a detector for measuring the observable result to generate specimen test results.

  8. Method and apparatus for recovering unstable cores

    DOEpatents

    McGuire, Patrick L.; Barraclough, Bruce L.

    1983-01-01

    A method and apparatus suitable for stabilizing hydrocarbon cores are given. Such stabilized cores have not previously been obtainable for laboratory study, and such study is believed to be required before the hydrate reserves can become a utilizable resource. The apparatus can be built using commercially available parts and is very simple and safe to operate.

  9. 33 CFR 67.10-1 - Apparatus requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Apparatus requirements. 67.10-1 Section 67.10-1 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO... signals § 67.10-1 Apparatus requirements. The sound signal required by §§ 67.20-10, 67.25-10, and 67.30-10...

  10. 33 CFR 67.10-1 - Apparatus requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Apparatus requirements. 67.10-1 Section 67.10-1 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO... signals § 67.10-1 Apparatus requirements. The sound signal required by §§ 67.20-10, 67.25-10, and 67.30-10...

  11. Apparatus For Eddy-Current Inspection Of Bolts

    NASA Technical Reports Server (NTRS)

    Amos, Jay M.

    1994-01-01

    Eddy-current apparatus for inspection of bolts, studs, and other threaded fasteners detects flaws in threads, shanks, and head fillets. With help of apparatus, technician quickly inspects fasteners of various dimensions. Accommodates fasteners with diameters from 0.190 in. to 1 in. and with lengths up to 5 in. Basic design modified to accommodate fasteners of other sizes.

  12. A prototype splitter apparatus for dividing large catches of small fish

    USGS Publications Warehouse

    Stapanian, Martin A.; Edwards, William H.

    2012-01-01

    Due to financial and time constraints, it is often necessary in fisheries studies to divide large samples of fish and estimate total catch from the subsample. The subsampling procedure may involve potential human biases or may be difficult to perform in rough conditions. We present a prototype gravity-fed splitter apparatus for dividing large samples of small fish (30–100 mm TL). The apparatus features a tapered hopper with a sliding and removable shutter. The apparatus provides a comparatively stable platform for objectively obtaining subsamples, and it can be modified to accommodate different sizes of fish and different sample volumes. The apparatus is easy to build, inexpensive, and convenient to use in the field. To illustrate the performance of the apparatus, we divided three samples (total N = 2,000 fish) composed of four fish species. Our results indicated no significant bias in estimating either the number or proportion of each species from the subsample. Use of this apparatus or a similar apparatus can help to standardize subsampling procedures in large surveys of fish. The apparatus could be used for other applications that require dividing a large amount of material into one or more smaller subsamples.

  13. Applicability of two automated disintegration apparatuses for rapidly disintegrating (mini)tablets.

    PubMed

    Sieber, Daniel; Lazzari, Alessia; Quodbach, Julian; Pein, Miriam

    2017-03-01

    Orally disintegrating (mini)tablets (OD(M)Ts) are of interest in the field of pharmaceutics. Their orodispersible character is defined by the disintegration time, which is measured with a basket apparatus according to the European Pharmacopoeia. This method, however, lacks applicability for ODTs and especially ODMTs. New disintegration apparatuses have been described in literature, but a qualification to assess the applicability has not been described. A qualification procedure for two automated disintegration apparatuses, OD-mate and Hermes apparatus, is introduced. Aspects of the operational qualification as well as precision and accuracy regarding a performance qualification were evaluated for both apparatuses analog to the ICH guideline Q2. While the OQ study is performed separately for each apparatus, accuracy and precision were performed following the same protocol for both testers. Small RSDs (16.9% OD-mate; 15.2% Hermes compared to 32.3% for the pharmacopeial method) were found despite very fast disintegration times (1.5 s for both apparatuses). By comparing these RSDs to practical examples, the authors propose threshold values for repeatability depending on the mean disintegration time. Obtained results from the qualification were used to assess the applicability of both apparatuses.

  14. 21 CFR 880.6740 - Vacuum-powered body fluid suction apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vacuum-powered body fluid suction apparatus. 880... Personal Use Miscellaneous Devices § 880.6740 Vacuum-powered body fluid suction apparatus. (a) Identification. A vacuum-powered body fluid suction apparatus is a device used to aspirate, remove, or sample...

  15. 21 CFR 880.6740 - Vacuum-powered body fluid suction apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vacuum-powered body fluid suction apparatus. 880... Personal Use Miscellaneous Devices § 880.6740 Vacuum-powered body fluid suction apparatus. (a) Identification. A vacuum-powered body fluid suction apparatus is a device used to aspirate, remove, or sample...

  16. Portable conduit retention apparatus for releasably retaining a conduit therein

    DOEpatents

    Metzger, Richard H.

    1998-01-01

    Portable conduit retention apparatus for releasably retaining a conduit therein. The apparatus releasably retains the conduit out of the way of nearby personnel and equipment. The apparatus includes a portable support frame defining a slot therein having an open mouth portion in communication with the slot for receiving the conduit through the open mouth portion and into the slot. A retention bar is pivotally connected to the support frame adjacent the mouth portion for releasably retaining the conduit in the slot. The retention bar freely pivots to a first position, so that the mouth portion is unblocked in order that the conduit is received through the mouth portion and into the slot. In addition, the retention bar freely pivots to a second position, so that the mouth portion is blocked in order that the conduit is retained in the slot. The conduit is released from the slot by pivoting the retention bar to the first position to unblock the mouth portion and thereafter manipulating the conduit from the slot and through the mouth portion. The apparatus may further include a mounting member attached to the support frame for mounting the apparatus on a vertical support surface. Another embodiment of the apparatus includes a shoe assembly of predetermined weight removably connected to the support frame for resting the apparatus on a floor in such a manner that the apparatus is substantially stationary on the floor.

  17. Portable conduit retention apparatus for releasably retaining a conduit therein

    DOEpatents

    Metzger, R.H.

    1998-07-07

    Portable conduit retention apparatus is described for releasably retaining a conduit therein. The apparatus releasably retains the conduit out of the way of nearby personnel and equipment. The apparatus includes a portable support frame defining a slot therein having an open mouth portion in communication with the slot for receiving the conduit through the open mouth portion and into the slot. A retention bar is pivotally connected to the support frame adjacent the mouth portion for releasably retaining the conduit in the slot. The retention bar freely pivots to a first position, so that the mouth portion is unblocked in order that the conduit is received through the mouth portion and into the slot. In addition, the retention bar freely pivots to a second position, so that the mouth portion is blocked in order that the conduit is retained in the slot. The conduit is released from the slot by pivoting the retention bar to the first position to unblock the mouth portion and thereafter manipulating the conduit from the slot and through the mouth portion. The apparatus may further include a mounting member attached to the support frame for mounting the apparatus on a vertical support surface. Another embodiment of the apparatus includes a shoe assembly of predetermined weight removably connected to the support frame for resting the apparatus on a floor in such a manner that the apparatus is substantially stationary on the floor. 6 figs.

  18. APPARATUS FOR HIGH PURITY METAL RECOVERY

    DOEpatents

    Magel, T.T.

    1959-02-10

    An apparatus is described for preparing high purity metal such as uranium, plutonium and the like from an impure mass of the same metal. The apparatus is arranged so that the impure metal is heated and swept by a stream of hydrogen gas bearing a halogen such as iodine. The volatiie metal halide formed is carried on to a hot filament where the metal halide is decomposed and the molten high purity metal is collected in a rceeiver below

  19. Methods and apparatus for measuring the tightness of enclosures

    DOEpatents

    Modera, Mark P.; Sherman, Max H.

    1987-01-13

    Disclosed are methods and apparatus for measuring tightness of an enclosure such as a building by utilizing alternating pressurization techniques. One method comprises providing apparatus capable of causing an internal volume change for the enclosure, the apparatus including a means for determining the instantaneous volume change, and a means for determining the instantaneous pressure within the enclosure. The apparatus is operated within the enclosure to change the volume thereof, and at least one of the frequency and the displacement is adjusted to achieve a root mean square pressure in the enclosure approximately equal to a reference pressure. At that pressure, the leakage of the enclosure is determined from the instantaneous displacement and instantaneous pressure values.

  20. Methods and apparatus for measuring the tightness of enclosures

    DOEpatents

    Modera, M.P.; Sherman, M.H.

    1987-01-13

    Disclosed are methods and apparatus for measuring tightness of an enclosure such as a building by utilizing alternating pressurization techniques. One method comprises providing apparatus capable of causing an internal volume change for the enclosure, the apparatus including a means for determining the instantaneous volume change, and a means for determining the instantaneous pressure within the enclosure. The apparatus is operated within the enclosure to change the volume thereof, and at least one of the frequency and the displacement is adjusted to achieve a root mean square pressure in the enclosure approximately equal to a reference pressure. At that pressure, the leakage of the enclosure is determined from the instantaneous displacement and instantaneous pressure values. 3 figs.

  1. Tensile-stressed microelectromechanical apparatus and tiltable micromirrors formed therefrom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fleming, James G.

    A microelectromechanical (MEM) apparatus is disclosed which includes a pair of tensile-stressed actuators suspending a platform above a substrate to tilt the platform relative to the substrate. A tensile stress built into the actuators initially tilts the platform when a sacrificial material used in fabrication of the MEM apparatus is removed. Further tilting of the platform can occur with a change in the ambient temperature about the MEM apparatus, or by applying a voltage to one or both of the tensile-stressed actuators. The MEM apparatus can be used to form a tiltable micromirror or an array of such devices, andmore » also has applications for thermal management within satellites.« less

  2. Multi-angle nuclear imaging apparatus and method

    DOEpatents

    Anger, Hal O. [Berkeley, CA

    1980-04-08

    Nuclear imaging apparatus for obtaining multi-plane readouts of radioactive material in a human or animal subject. A probe disposed in the vicinity of the subject is provided for receiving radiation from radiating sources in the subject and for forming a probe radiation image. The probe has a collimator with different portions thereof having holes disposed at different angles. A single scintillation crystal overlies the collimator for receiving radiation passing through the collimator and producing scintillations to provide the probe image. An array of photomultiplier tubes overlie the single crystal for observing the probe image and providing electrical outputs. Conversion apparatus is provided for converting the electrical outputs representing the probe image into optical images displayed on the screen of a cathode ray tube. Divider apparatus is provided for dividing the probe radiation image into a plurality of areas with the areas corresponding to different portions of the collimator having holes disposed at different angles. A light sensitive medium is provided for receiving optical images. Apparatus is provided for causing relative movement between the probe and the subject. Apparatus is also provided for causing relative movement between the optical image on the screen and the light sensitive medium which corresponds to the relative movement between the probe and the subject whereby there is produced on the light sensitive medium a plurality of images that portray the subject as seen from different angles corresponding to the portions of the collimator having holes at different angles.

  3. Pellet inspection apparatus

    DOEpatents

    Wilks, Robert S.; Taleff, Alexander; Sturges, Jr., Robert H.

    1982-01-01

    Apparatus for inspecting nuclear fuel pellets in a sealed container for diameter, flaws, length and weight. The apparatus includes, in an array, a pellet pick-up station, four pellet inspection stations and a pellet sorting station. The pellets are delivered one at a time to the pick-up station by a vibrating bowl through a vibrating linear conveyor. Grippers each associated with a successive pair of the stations are reciprocable together to pick up a pellet at the upstream station of each pair and to deposit the pellet at the corresponding downstream station. The gripper jaws are opened selectively depending on the state of the pellets at the stations and the particular cycle in which the apparatus is operating. Inspection for diameter, flaws and length is effected in each case by a laser beam projected on the pellets by a precise optical system while each pellet is rotated by rollers. Each laser and its optical system are mounted in a container which is free standing on a precise surface and is provided with locating buttons which engage locating holes in the surface so that each laser and its optical system is precisely set. The roller stands are likewise free standing and are similarly precisely positioned. The diameter optical system projects a thin beam of light which scans across the top of each pellet and is projected on a diode array. The fl GOVERNMENT CONTRACT CLAUSE The invention herein described was made in the course of or under a contract or subcontract thereunder with the Department of Energy bearing No. EY-67-14-C-2170.

  4. Microfabricated, flowthrough porous apparatus for discrete detection of binding reactions

    DOEpatents

    Beattie, Kenneth L.

    1998-01-01

    An improved microfabricated apparatus for conducting a multiplicity of individual and simultaneous binding reactions is described. The apparatus comprises a substrate on which are located discrete and isolated sites for binding reactions. The apparatus is characterized by discrete and isolated regions that extend through said substrate and terminate on a second surface thereof such that when a test sample is allowed to the substrate, it is capable of penetrating through each such region during the course of said binding reaction. The apparatus is especially useful for sequencing by hybridization of DNA molecules.

  5. 21 CFR 884.5900 - Therapeutic vaginal douche apparatus.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Therapeutic vaginal douche apparatus. 884.5900... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Therapeutic Devices § 884.5900 Therapeutic vaginal douche apparatus. (a) Identification. A therapeutic vaginal douche...

  6. 21 CFR 884.5900 - Therapeutic vaginal douche apparatus.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Therapeutic vaginal douche apparatus. 884.5900... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Therapeutic Devices § 884.5900 Therapeutic vaginal douche apparatus. (a) Identification. A therapeutic vaginal douche...

  7. 21 CFR 884.5900 - Therapeutic vaginal douche apparatus.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Therapeutic vaginal douche apparatus. 884.5900... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Therapeutic Devices § 884.5900 Therapeutic vaginal douche apparatus. (a) Identification. A therapeutic vaginal douche...

  8. CASTING APPARATUS

    DOEpatents

    Gray, C.F.; Thompson, R.H.

    1958-09-23

    An apparatus is described for casting small quantities of uranlum. It consists of a crucible having a hole in the bottom with a mold positioned below. A vertical rcd passes through the hole in the crucible and has at its upper end a piercing head adapted to break the oxide skin encasing a molten uranium body. An air tight cylinder surrounds the crucible and mold, and is arranged to be evacuated.

  9. Golgi apparatus partitioning during cell division.

    PubMed

    Rabouille, Catherine; Jokitalo, Eija

    2003-01-01

    This review discusses the mitotic segregation of the Golgi apparatus. The results from classical biochemical and morphological studies have suggested that in mammalian cells this organelle remains distinct during mitosis, although highly fragmented through the formation of mitotic Golgi clusters of small tubules and vesicles. Shedding of free Golgi-derived vesicles would consume Golgi clusters and disperse this organelle throughout the cytoplasm. Vesicles could be partitioned in a stochastic and passive way between the two daughter cells and act as a template for the reassembly of this key organelle. This model has recently been modified by results obtained using GFP- or HRP-tagged Golgi resident enzymes, live cell imaging and electron microscopy. Results obtained with these techniques show that the mitotic Golgi clusters are stable entities throughout mitosis that partition in a microtubule spindle-dependent fashion. Furthermore, a newer model proposes that at the onset of mitosis, the Golgi apparatus completely loses its identity and is reabsorbed into the endoplasmic reticulum. This suggests that the partitioning of the Golgi apparatus is entirely dependent on the partitioning of the endoplasmic reticulum. We critically discuss both models and summarize what is known about the molecular mechanisms underlying the Golgi disassembly and reassembly during and after mitosis. We will also review how the study of the Golgi apparatus during mitosis in other organisms can answer current questions and perhaps reveal novel mechanisms.

  10. APPARATUS FOR THE PRODUCTION OF LITHIUM METAL

    DOEpatents

    Baker, P.S.; Duncan, F.R.; Greene, H.B.

    1961-08-22

    Methods and apparatus for the production of high-purity lithium from lithium halides are described. The apparatus is provided for continuously contacting a molten lithium halide with molten barium, thereby forming lithium metal and a barium halide, establishing separate layers of these reaction products and unreacted barium and lithium halide, and continuously withdrawing lithium and barium halide from the reaction zone. (AEC)

  11. Microgravity science and applications: Apparatus and facilities

    NASA Technical Reports Server (NTRS)

    1989-01-01

    NASA support apparatus and facilities for microgravity research are summarized in fact sheets. The facilities are ground-based simulation environments for short-term experiments, and the shuttle orbiter environment for long duration experiments. The 17 items of the microgravitational experimental apparatus are described. Electronic materials, alloys, biotechnology, fluid dynamics and transport phenomena, glasses and ceramics, and combustion science are among the topics covered.

  12. Report on the 2006 AAPT Apparatus Competition

    ERIC Educational Resources Information Center

    Flarend, Richard

    2007-01-01

    Each year at the AAPT summer meeting there is an apparatus competition in which members of the physics community can share ideas for new or improved apparatus to aid in the teaching of physics. The 2006 competition at the summer meeting in Syracuse, NY, was the largest competition in quite a while and continued an upward trend in the number of…

  13. Pulse circuit apparatus for gas discharge laser

    DOEpatents

    Bradley, Laird P.

    1980-01-01

    Apparatus and method using a unique pulse circuit for a known gas discharge laser apparatus to provide an electric field for preconditioning the gas below gas breakdown and thereafter to place a maximum voltage across the gas which maximum voltage is higher than that previously available before the breakdown voltage of that gas laser medium thereby providing greatly increased pumping of the laser.

  14. Wet atmospheric generation apparatus

    NASA Technical Reports Server (NTRS)

    Hamner, Richard M. (Inventor); Allen, Janice K. (Inventor)

    1990-01-01

    The invention described relates to an apparatus for providing a selectively humidified gas to a camera canister containing cameras and film used in space. A source of pressurized gas (leak test gas or motive gas) is selected by a valve, regulated to a desired pressure by a regulator, and routed through an ejector (venturi device). A regulated source of water vapor in the form of steam from a heated reservoir is coupled to a low pressure region of the ejector which mixes with high velocity gas flow through the ejector. This mixture is sampled by a dew point sensor to obtain dew point thereof (ratio of water vapor to gas) and the apparatus adjusted by varying gas pressure or water vapor to provide a mixture at a connector having selected humidity content.

  15. 42 CFR 84.95 - Service time test; open-circuit apparatus.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... classified according to the length of time it supplies air or oxygen to the breathing machine. (c) The... 42 Public Health 1 2013-10-01 2013-10-01 false Service time test; open-circuit apparatus. 84.95...-Contained Breathing Apparatus § 84.95 Service time test; open-circuit apparatus. (a) Service time will be...

  16. 42 CFR 84.95 - Service time test; open-circuit apparatus.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... classified according to the length of time it supplies air or oxygen to the breathing machine. (c) The... 42 Public Health 1 2012-10-01 2012-10-01 false Service time test; open-circuit apparatus. 84.95...-Contained Breathing Apparatus § 84.95 Service time test; open-circuit apparatus. (a) Service time will be...

  17. 42 CFR 84.95 - Service time test; open-circuit apparatus.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... classified according to the length of time it supplies air or oxygen to the breathing machine. (c) The... 42 Public Health 1 2014-10-01 2014-10-01 false Service time test; open-circuit apparatus. 84.95...-Contained Breathing Apparatus § 84.95 Service time test; open-circuit apparatus. (a) Service time will be...

  18. Automated High-Temperature Hall-Effect Apparatus

    NASA Technical Reports Server (NTRS)

    Parker, James B.; Zoltan, Leslie D.

    1992-01-01

    Automated apparatus takes Hall-effect measurements of specimens of thermoelectric materials at temperatures from ambient to 1,200 K using computer control to obtain better resolution of data and more data points about three times as fast as before. Four-probe electrical-resistance measurements taken in 12 electrical and 2 magnetic orientations to characterize specimens at each temperature. Computer acquires data, and controls apparatus via three feedback loops: one for temperature, one for magnetic field, and one for electrical-potential data.

  19. Method and Apparatus for Concentrating Vapors for Analysis

    DOEpatents

    Grate, Jay W.; Baldwin, David L.; Anheier, Jr., Norman C.

    2008-10-07

    An apparatus and method are disclosed for pre-concentrating gaseous vapors for analysis. The invention finds application in conjunction with, e.g., analytical instruments where low detection limits for gaseous vapors are desirable. Vapors sorbed and concentrated within the bed of the apparatus can be thermally desorbed achieving at least partial separation of vapor mixtures. The apparatus is suitable, e.g., for preconcentration and sample injection, and provides greater resolution of peaks for vapors within vapor mixtures, yielding detection levels that are 10-10,000 times better than for direct sampling and analysis systems. Features are particularly useful for continuous unattended monitoring applications.

  20. Dissolution Studies of Papaverine Hydrochloride from Tablets in Three Pharmacopoeia Apparatuses.

    PubMed

    Polski, Andrzej; Kasperek, Regina; Rogowska, Magdalena; Iwaniak, Karol; Sobòtka-Polska, Karolina; Poleszak, Ewa

    2015-01-01

    In tablet production, the most important aspects are the physical properties of the tablets and their dissolution studies, which can be performed in four pharmacopoeial apparatuses. There are differences between them in construction and action, so differences in the results obtained are possible. The aim of the study was to compare the release of a model drug substance (papaverine hydrochloride) from tablets in three pharmacopoeial dissolution apparatus: a basket, a paddle (closed system) and flow-through cell (open system). The one series of tablets were produced by direct compression in a tablet press. The physical properties of the tablets (weight and size uniformity test, friability and hardness tests, disintegration time test), drug content and the release study of papaverine hydrochloride from tablets were studied in three dissolution apparatuses. The content of the active substance was studied spectrophotometrically. All tablets met the pharmacopoeic requirements. Over 80% of the model substance released from the tablets after 14 min in flow through the cell apparatus, while in the basket and paddle apparatuses after about 7 min 30 sec. After 20 min, the amount of the substance released in all apparatuses was over 90%. The release profiles of the drug substance in paddle and basket apparatuses were similar, while in the flow-through cell apparatus it was slightly slower. When the study conditions and composition of the tablets are the same, the release profile of the drug can be affected by the type of dissolution apparatus.