NASA Astrophysics Data System (ADS)
Hao, Huadong; Shi, Haolei; Yi, Pengju; Liu, Ying; Li, Cunjun; Li, Shuguang
2018-01-01
A Volume Metrology method based on Internal Electro-optical Distance-ranging method is established for large vertical energy storage tank. After analyzing the vertical tank volume calculation mathematical model, the key processing algorithms, such as gross error elimination, filtering, streamline, and radius calculation are studied for the point cloud data. The corresponding volume values are automatically calculated in the different liquids by calculating the cross-sectional area along the horizontal direction and integrating from vertical direction. To design the comparison system, a vertical tank which the nominal capacity is 20,000 m3 is selected as the research object, and there are shown that the method has good repeatability and reproducibility. Through using the conventional capacity measurement method as reference, the relative deviation of calculated volume is less than 0.1%, meeting the measurement requirements. And the feasibility and effectiveness are demonstrated.
Large volume multiple-path nuclear pumped laser
NASA Technical Reports Server (NTRS)
Hohl, F.; Deyoung, R. J. (Inventor)
1981-01-01
Large volumes of gas are excited by using internal high reflectance mirrors that are arranged so that the optical path crosses back and forth through the excited gaseous medium. By adjusting the external dielectric mirrors of the laser, the number of paths through the laser cavity can be varied. Output powers were obtained that are substantially higher than the output powers of previous nuclear laser systems.
ERIC Educational Resources Information Center
Rutkowski, David J.; Prusinski, Ellen L.
2011-01-01
The staff of the Center for Evaluation & Education Policy (CEEP) at Indiana University is often asked about how international large-scale assessments influence U.S. educational policy. This policy brief is designed to provide answers to some of the most frequently asked questions encountered by CEEP researchers concerning the three most popular…
A comparison of methods to quantify the in-season training load of professional soccer players.
Scott, Brendan R; Lockie, Robert G; Knight, Timothy J; Clark, Andrew C; Janse de Jonge, Xanne A K
2013-03-01
To compare various measures of training load (TL) derived from physiological (heart rate [HR]), perceptual (rating of perceived exertion [RPE]), and physical (global positioning system [GPS] and accelerometer) data during in-season field-based training for professional soccer. Fifteen professional male soccer players (age 24.9 ± 5.4 y, body mass 77.6 ± 7.5 kg, height 181.1 ± 6.9 cm) were assessed in-season across 97 individual training sessions. Measures of external TL (total distance [TD], the volume of low-speed activity [LSA; <14.4 km/h], high-speed running [HSR; >14.4 km/h], very high-speed running [VHSR; >19.8 km/h], and player load), HR and session-RPE (sRPE) scores were recorded. Internal TL scores (HR-based and sRPE-based) were calculated, and their relationships with measures of external TL were quantified using Pearson product-moment correlations. Physical measures of TD, LSA volume, and player load provided large, significant (r = .71-.84; P < .01) correlations with the HR-based and sRPE-based methods. Volume of HSR and VHSR provided moderate to large, significant (r = .40-.67; P < .01) correlations with measures of internal TL. While the volume of HSR and VHSR provided significant relationships with internal TL, physical-performance measures of TD, LSA volume, and player load appear to be more acceptable indicators of external TL, due to the greater magnitude of their correlations with measures of internal TL.
ERIC Educational Resources Information Center
Bergeron, Jacques C., Ed.; And Others
The Proceedings of PME-XI has been published in three separate volumes because of the large total of 161 individual conference papers reported. Volume I contains four plenary papers, all on the subject of "constructivism," and 44 commented papers arranged under 4 themes. Volume II contains 56 papers (39 commented; 17 uncommented)…
ERIC Educational Resources Information Center
da Ponte, Joao Pedro, Ed.; Matos, Joao Filipe, Ed.
The Proceedings of PME-XVIII have been published in four separate volumes because of the large number of individual conference papers reported. Volume I contains brief reports for 11 Working Groups and 8 Discussion Groups, 55 "Short Oral Communications," 28 Posters, 5 Plenary Panel reports, and 4 Plenary Session reports. Volume II…
ERIC Educational Resources Information Center
Hirabayashi, Ichiei, Ed.; And Others
The Proceedings of PME-XVII has been published in three volumes because of the large number of papers presented at the conference. Volume I contains a brief Plenary Panel report, 4 full-scale Plenary Addresses, the brief reports of 10 Working Groups and 4 Discussion Groups, and a total of 23 Research Reports grouped under 4 themes. Volume II…
Free space-planning solutions in the architecture of multi-storey buildings
NASA Astrophysics Data System (ADS)
Ibragimov, Alexander; Danilov, Alexander
2018-03-01
Here some aspects of the development of steel frame structure design from the standpoint of geometry and morphogenesis of bearing steel structures of civil engineering objects. An alternative approach to forming constructive schemes may be application of curved steel elements in the main load-bearing system. As an example, it may be circular and parabolic arches or segments of varying outline and orientation. The considered approach implies creating large internal volumes without loss in the load-bearing capacity of the frame. The basic concept makes possible a wide variety of layout and design solutions. The presence of free internal spaces of large volume in buildings of a "skyscraper" type contributes to resolving a great number of problems, including those of communicative nature.
Basics of Sterile Compounding: Particulate Matter.
Akers, Michael J
2017-01-01
This article focuses on the requirements for particulate matter in sterile products. Topics include particles and quality, particulate matter standards (large- and small-volume injectables), development of the small-volume injectable test, electronic (light obscuration) and microscope testing, and special requirements for particulate matter in biopharmaceutical preparations. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
Performance of internal covariance estimators for cosmic shear correlation functions
Friedrich, O.; Seitz, S.; Eifler, T. F.; ...
2015-12-31
Data re-sampling methods such as the delete-one jackknife are a common tool for estimating the covariance of large scale structure probes. In this paper we investigate the concepts of internal covariance estimation in the context of cosmic shear two-point statistics. We demonstrate how to use log-normal simulations of the convergence field and the corresponding shear field to carry out realistic tests of internal covariance estimators and find that most estimators such as jackknife or sub-sample covariance can reach a satisfactory compromise between bias and variance of the estimated covariance. In a forecast for the complete, 5-year DES survey we show that internally estimated covariance matrices can provide a large fraction of the true uncertainties on cosmological parameters in a 2D cosmic shear analysis. The volume inside contours of constant likelihood in themore » $$\\Omega_m$$-$$\\sigma_8$$ plane as measured with internally estimated covariance matrices is on average $$\\gtrsim 85\\%$$ of the volume derived from the true covariance matrix. The uncertainty on the parameter combination $$\\Sigma_8 \\sim \\sigma_8 \\Omega_m^{0.5}$$ derived from internally estimated covariances is $$\\sim 90\\%$$ of the true uncertainty.« less
David W. MacFarlane
2015-01-01
Accurately assessing forest biomass potential is contingent upon having accurate tree biomass models to translate data from forest inventories. Building generality into these models is especially important when they are to be applied over large spatial domains, such as regional, national and international scales. Here, new, generalized whole-tree mass / volume...
Atmospheric Gaseous Plasma with Large Dimensions
NASA Astrophysics Data System (ADS)
Korenev, Sergey
2012-10-01
The forming of atmospheric plasma with large dimensions using electrical discharge typically uses the Dielectric Barrier Discharge (DBD). The study of atmospheric DBD was shown some problems related to homogeneous volume plasma. The volume of this plasma determines by cross section and gas gap between electrode and dielectric. The using of electron beam for volume ionization of air molecules by CW relativistic electron beams was shown the high efficiency of this process [1, 2]. The main advantage of this approach consists in the ionization of gas molecules by electrons in longitudinal direction determines by their kinetic energy. A novel method for forming of atmospheric homogeneous plasma with large volume dimensions using ionization of gas molecules by pulsed non-relativistic electron beams is presented in the paper. The results of computer modeling for delivered doses of electron beams in gases and ionization are discussed. The structure of experimental bench with plasma diagnostics is considered. The preliminary results of forming atmospheric plasma with ionization gas molecules by pulsed nanosecond non-relativistic electron beam are given. The analysis of potential applications for atmospheric volume plasma is presented. Reference: [1] S. Korenev. ``The ionization of air by scanning relativistic high power CW electron beam,'' 2002 IEEE International Conference on Plasma Science. May 2002, Alberta, Canada. [2] S. Korenev, I. Korenev. ``The propagation of high power CW scanning electron beam in air.'' BEAMS 2002: 14th International Conference on High-Power Particle Beams, Albuquerque, New Mexico (USA), June 2002, AIP Conference Proceedings Vol. 650(1), pp. 373-376. December 17.
ERIC Educational Resources Information Center
Geeslin, William, Ed.; Graham, Karen, Ed.
The Proceedings of PME-XVI has been published in three volumes because of the large number of papers presented at the conference. Volume 1 contains: (1) brief reports from each of the 11 standing Working Groups on their respective roles in organizing PME-XVI; (2) brief reports from 6 Discussion Groups; and (3) 35 research reports covering authors…
Medvedovici, Andrei; Udrescu, Stefan; Albu, Florin; Tache, Florentin; David, Victor
2011-09-01
Liquid-liquid extraction of target compounds from biological matrices followed by the injection of a large volume from the organic layer into the chromatographic column operated under reversed-phase (RP) conditions would successfully combine the selectivity and the straightforward character of the procedure in order to enhance sensitivity, compared with the usual approach of involving solvent evaporation and residue re-dissolution. Large-volume injection of samples in diluents that are not miscible with the mobile phase was recently introduced in chromatographic practice. The risk of random errors produced during the manipulation of samples is also substantially reduced. A bioanalytical method designed for the bioequivalence of fenspiride containing pharmaceutical formulations was based on a sample preparation procedure involving extraction of the target analyte and the internal standard (trimetazidine) from alkalinized plasma samples in 1-octanol. A volume of 75 µl from the octanol layer was directly injected on a Zorbax SB C18 Rapid Resolution, 50 mm length × 4.6 mm internal diameter × 1.8 µm particle size column, with the RP separation being carried out under gradient elution conditions. Detection was made through positive ESI and MS/MS. Aspects related to method development and validation are discussed. The bioanalytical method was successfully applied to assess bioequivalence of a modified release pharmaceutical formulation containing 80 mg fenspiride hydrochloride during two different studies carried out as single-dose administration under fasting and fed conditions (four arms), and multiple doses administration, respectively. The quality attributes assigned to the bioanalytical method, as resulting from its application to the bioequivalence studies, are highlighted and fully demonstrate that sample preparation based on large-volume injection of immiscible diluents has an increased potential for application in bioanalysis.
NASA Astrophysics Data System (ADS)
Kassoy, D. R.
2014-01-01
Systematic asymptotic methods are applied to the compressible conservation and state equations for a reactive gas, including transport terms, to develop a rational thermomechanical formulation for the ignition of a chemical reaction following time-resolved, spatially distributed thermal energy addition from an external source into a finite volume of gas. A multi-parameter asymptotic analysis is developed for a wide range of energy deposition levels relative to the initial internal energy in the volume when the heating timescale is short compared to the characteristic acoustic timescale of the volume. Below a quantitatively defined threshold for energy addition, a nearly constant volume heating process occurs, with a small but finite internal gas expansion Mach number. Very little added thermal energy is converted to kinetic energy. The gas expelled from the boundary of the hot, high-pressure spot is the source of mechanical disturbances (acoustic and shock waves) that propagate away into the neighbouring unheated gas. When the energy addition reaches the threshold value, the heating process is fully compressible with a substantial internal gas expansion Mach number, the source of blast waves propagating into the unheated environmental gas. This case corresponds to an extremely large non-dimensional hot-spot temperature and pressure. If the former is sufficiently large, a high activation energy chemical reaction is initiated on the short heating timescale. This phenomenon is in contrast to that for more modest levels of energy addition, where a thermal explosion occurs only after the familiar extended ignition delay period for a classical high activation reaction. Transport effects, modulated by an asymptotically small Knudsen number, are shown to be negligible unless a local gradient in temperature, concentration or velocity is exceptionally large.
Three-dimensional cinematography with control object of unknown shape.
Dapena, J; Harman, E A; Miller, J A
1982-01-01
A technique for reconstruction of three-dimensional (3D) motion which involves a simple filming procedure but allows the deduction of coordinates in large object volumes was developed. Internal camera parameters are calculated from measurements of the film images of two calibrated crosses while external camera parameters are calculated from the film images of points in a control object of unknown shape but at least one known length. The control object, which includes the volume in which the activity is to take place, is formed by a series of poles placed at unknown locations, each carrying two targets. From the internal and external camera parameters, and from locations of the images of point in the films of the two cameras, 3D coordinates of the point can be calculated. Root mean square errors of the three coordinates of points in a large object volume (5m x 5m x 1.5m) were 15 mm, 13 mm, 13 mm and 6 mm, and relative errors in lengths averaged 0.5%, 0.7% and 0.5%, respectively.
ERIC Educational Resources Information Center
Schmitt, Mary Jane, Ed.; Safford-Ramus, Katherine, Ed.
This volume contains the proceedings of the 7th international conference on Adults Learning Mathematics--A Research Forum held in July, 2000 in Massachusetts. It includes posters and short oral reports under these section headings: (1) Research into Practice; (2) Large- Scale Issues: Frameworks, Standards, and Assessment; (3) Theoretical…
NASA Astrophysics Data System (ADS)
Moreno, Javier; Somolinos, Álvaro; Romero, Gustavo; González, Iván; Cátedra, Felipe
2017-08-01
A method for the rigorous computation of the electromagnetic scattering of large dielectric volumes is presented. One goal is to simplify the analysis of large dielectric targets with translational symmetries taken advantage of their Toeplitz symmetry. Then, the matrix-fill stage of the Method of Moments is efficiently obtained because the number of coupling terms to compute is reduced. The Multilevel Fast Multipole Method is applied to solve the problem. Structured meshes are obtained efficiently to approximate the dielectric volumes. The regular mesh grid is achieved by using parallelepipeds whose centres have been identified as internal to the target. The ray casting algorithm is used to classify the parallelepiped centres. It may become a bottleneck when too many points are evaluated in volumes defined by parametric surfaces, so a hierarchical algorithm is proposed to minimize the number of evaluations. Measurements and analytical results are included for validation purposes.
Physics through the 1990s: An overview
NASA Technical Reports Server (NTRS)
1986-01-01
The volume details the interaction of physics and society, and presents a short summary of the progress in the major fields of physics and a summary of the other seven volumes of the Physics through the 1990s series, issues and recommended policy changes are described regarding funding, education, industry participation, small-group university research and large facility programs, government agency programs, and computer database needs. Three supplements report in detail on international issues in physics (the US position in the field, international cooperation and competition-especially on large projects, freedom for scientists, free flow of information, and education of foreign students), the education and supply of physicists (the changes in US physics education, employment and manpower, and demographics of the field), and the organization and support of physics (government, university, and industry research; facilities; national laboratories; and decision making). An executive summary contains recommendations for maintaining excellence in physics. A glossary of scientific terms is appended.
Leypoldt, John K; Akonur, Alp; Agar, Baris U; Culleton, Bruce F
2012-10-01
The kinetics of plasma phosphorus concentrations during hemodialysis (HD) are complex and cannot be described by conventional one- or two-compartment kinetic models. It has recently been shown by others that the physiologic (or apparent distribution) volume for phosphorus (Vr-P) increases with increasing treatment time and shows a large variation among patients treated by thrice weekly and daily HD. Here, we describe the dependence of Vr-P on treatment time and predialysis plasma phosphorus concentration as predicted by a novel pseudo one-compartment model. The kinetics of plasma phosphorus during conventional and six times per week daily HD were simulated as a function of treatment time per session for various dialyzer phosphate clearances and patient-specific phosphorus mobilization clearances (K(M)). Vr-P normalized to extracellular volume from these simulations were reported and compared with previously published empirical findings. Simulated results were relatively independent of dialyzer phosphate clearance and treatment frequency. In contrast, Vr-P was strongly dependent on treatment time per session; the increase in Vr-P with treatment time was larger for higher values of K(M). Vr-P was inversely dependent on predialysis plasma phosphorus concentration. There was significant variation among predicted Vr-P values, depending largely on the value of K(M). We conclude that a pseudo one-compartment model can describe the empirical dependence of the physiologic volume of phosphorus on treatment time and predialysis plasma phosphorus concentration. Further, the variation in physiologic volume of phosphorus among HD patients is largely due to differences in patient-specific phosphorus mobilization clearance. © 2012 The Authors. Hemodialysis International © 2012 International Society for Hemodialysis.
ERIC Educational Resources Information Center
Khachatryan, George A.; Romashov, Andrey V.; Khachatryan, Alexander R.; Gaudino, Steven J.; Khachatryan, Julia M.; Guarian, Konstantin R.; Yufa, Nataliya V.
2014-01-01
Effective mathematics teachers have a large body of professional knowledge, which is largely undocumented and shared by teachers working in a given country's education system. The volume and cultural nature of this knowledge make it particularly challenging to share curricula and instructional methods between countries. Thus, approaches based on…
America's container ports : freight hubs that connect our nation to global markets
DOT National Transportation Integrated Search
2009-06-01
The U.S. marine transportation system continues to handle large volumes of domestic and international : freight in support of the nations economic activities. The demand for freight transportation : responds to trends in global economic activity a...
Song, Yan; Dhodda, Raj; Zhang, Jun; Sydor, Jens
2014-05-01
In the recent past, we have seen an increase in the outsourcing of bioanalysis in pharmaceutical companies in support of their drug development pipeline. This trend is largely driven by the effort to reduce internal cost, especially in support of late-stage pipeline assets where established bioanalytical assays are used to analyze a large volume of samples. This article will highlight our perspective of how bioanalytical laboratories within pharmaceutical companies can be developed into the best partner in the advancement of drug development pipelines with high-quality support at competitive cost.
Role of naturally occurring gas hydrates in sediment transport
DOE Office of Scientific and Technical Information (OSTI.GOV)
McIver, R.D.
1982-06-01
Naturally occurring gas hydrates have the potential to store enormous volumes of both gas and water in semi-solid form in ocean-bottom sediments and then to release that gas and water when the hydrate's equilibrium condition are disturbed. Therefore, hydrates provide a potential mechanism for transporting large volumes of sediments. Under the combined low bottom-water temperatures and moderate hydrostatic pressures that exist over most of the continental slopes and all of the continental rises and abyssal plains, hydrocarbon gases at or near saturation in the interstitial waters of the near-bottom sediments will form hydrates. The gas can either be autochthonous, microbiallymore » produced gas, or allochthonous, catagenic gas from deeper sediments. Equilibrium conditions that stabilize hydrated sediments may be disturbed, for example, by continued sedimentation or by lowering of sea level. In either case, some of the solid gas-water matrix decomposes. Released gas and water volume exceeds the volume occupied by the hydrate, so the internal pressure rises - drastically if large volumes of hydrate are decomposed. Part of the once rigid sediment is converted to a gas- and water-rich, relatively low density mud. When the internal pressure, due to the presence of the compressed gas or to buoyancy, is sufficiently high, the overlying sediment may be lifted and/or breached, and the less dense, gas-cut mud may break through. Such hydrate-related phenomena can cause mud diapirs, mud volcanos, mud slides, or turbidite flows, depending on sediment configuration and bottom topography. 4 figures.« less
Have Large Dams Altered Extreme Precipitation Patterns?
NASA Astrophysics Data System (ADS)
Hossain, Faisal; Jeyachandran, Indumathi; Pielke, Roger
2009-12-01
Dams and their impounded waters are among the most common civil infrastructures, with a long heritage of modern design and operations experience. In particular, large dams, defined by the International Commission on Large Dams (ICOLD) as having a height greater than 15 meters from the foundation and holding a reservoir volume of more than 3 million cubic meters, have the potential to vastly transform local climate, landscapes, regional economics, and urbanization patterns. In the United States alone, about 75,000 dams are capable of storing a volume of water equaling almost 1 year's mean runoff of the nation [Graf, 1999]. The World Commission on Dams (WCD) reports that at least 45,000 large dams have been built worldwide since the 1930s. These sheer numbers raise the question of the extent to which large dams and their impounded waters alter patterns that would have been pervasive had the dams not been built.
Quality evaluation of radiographic contrast media in large-volume prefilled syringes and vials.
Sendo, T; Hirakawa, M; Yaginuma, M; Aoyama, T; Oishi, R
1998-06-01
The authors compared the particle contaminations of radiographic contrast media packaged in large-volume prefilled syringes and vials. Particle counting was performed for four contrast media packaged in large-volume prefilled syringes (iohexol, ioversol, ioversol for angiography, and ioxaglate) and three contrast media packaged in vials (iohexol, ioversol, and ioxaglate). X-ray emission spectrometry was performed to characterize the individual particles. The amount of silicone oil in the syringe was quantified with infrared spectrophotometry. The particle contamination in syringes containing ioversol was higher than that in syringes containing iohexol or ioxaglate. Particle contamination in the vials was relatively low, except with ioxaglate. X-ray emission spectrometry of the components of the syringe and vial showed that the source of particles was internal material released from the rubber stopper or inner surface. The particle counts for contrast media packaged in syringes and vials varied considerably among the different contrast media and were related to the amount of silicone oil on the inner surface and rubber piston of the syringe.
NASA Astrophysics Data System (ADS)
Mizuki, Hidenobu; Ito, Yudai; Harada, Hisashi; Uezu, Kazuya
Zr(IV) surface-immobilized resins for removal of fluoride ion were prepared by surface template polymerization using polystyrene as a porogen. At polymerization, polystyrene was added in order to increase mesopores (2-50 nm) and macropore (>50 nm) with large macropores (around 300 nm) formed with internal aqueous phase of W⁄O emulsion. The pore structure of Zr(IV) surface-immobilized resins was evaluated by measuring specific surface area, pore volume, and pore size distribution with volumetric adsorption measurement instrument and mercury porosimeter. The adsorption isotherms were well fitted by Langmuir equation. The removal of fluoride was also carried out with column method. Zr(IV) surface-immobilized resins, using 10 g⁄L polystyrene in toluene at polymerization, possessed higher volume of not only mesopores and macropores but also large macropores. Furethermore, by adding the polystyrene with smaller molecular size, the pore volume of mesopores, macropores and large macropores was significantly increased, and the fluoride ion adsorption capacity and the column utilization also increased.
Li, Yongtao; Whitaker, Joshua S; McCarty, Christina L
2012-07-06
A large volume direct aqueous injection method was developed for the analysis of iodinated haloacetic acids in drinking water by using reversed-phase liquid chromatography/electrospray ionization/tandem mass spectrometry in the negative ion mode. Both the external and internal standard calibration methods were studied for the analysis of monoiodoacetic acid, chloroiodoacetic acid, bromoiodoacetic acid, and diiodoacetic acid in drinking water. The use of a divert valve technique for the mobile phase solvent delay, along with isotopically labeled analogs used as internal standards, effectively reduced and compensated for the ionization suppression typically caused by coexisting common inorganic anions. Under the optimized method conditions, the mean absolute and relative recoveries resulting from the replicate fortified deionized water and chlorinated drinking water analyses were 83-107% with a relative standard deviation of 0.7-11.7% and 84-111% with a relative standard deviation of 0.8-12.1%, respectively. The method detection limits resulting from the external and internal standard calibrations, based on seven fortified deionized water replicates, were 0.7-2.3 ng/L and 0.5-1.9 ng/L, respectively. Copyright © 2012 Elsevier B.V. All rights reserved.
The Comet Halley archive: Summary volume
NASA Technical Reports Server (NTRS)
Sekanina, Zdenek (Editor); Fry, Lori (Editor)
1991-01-01
The contents are as follows: The Organizational History of the International Halley Watch; Operations of the International Halley Watch from a Lead Center Perspective; The Steering Group; Astrometry Network; Infrared Studies Network; Large-Scale Phenomena Network; Meteor Studies Network; Near-Nucleus Studies Network; Photometry and Polarimetry Network; Radio Science Network; Spectroscopy and Spectrophotometry Network; Amateur Observation Network; Use of the CD-ROM Archive; The 1986 Passage of Comet Halley; and Recent Observations of Comet Halley.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goodsitt, Mitchell M., E-mail: goodsitt@umich.edu; Shenoy, Apeksha; Howard, David
2014-05-15
Purpose: To evaluate a three-equation three-unknown dual-energy quantitative CT (DEQCT) technique for determining region specific variations in bone spongiosa composition for improved red marrow dose estimation in radionuclide therapy. Methods: The DEQCT method was applied to 80/140 kVp images of patient-simulating lumbar sectional body phantoms of three sizes (small, medium, and large). External calibration rods of bone, red marrow, and fat-simulating materials were placed beneath the body phantoms. Similar internal calibration inserts were placed at vertebral locations within the body phantoms. Six test inserts of known volume fractions of bone, fat, and red marrow were also scanned. External-to-internal calibration correctionmore » factors were derived. The effects of body phantom size, radiation dose, spongiosa region segmentation granularity [single (∼17 × 17 mm) region of interest (ROI), 2 × 2, and 3 × 3 segmentation of that single ROI], and calibration method on the accuracy of the calculated volume fractions of red marrow (cellularity) and trabecular bone were evaluated. Results: For standard low dose DEQCT x-ray technique factors and the internal calibration method, the RMS errors of the estimated volume fractions of red marrow of the test inserts were 1.2–1.3 times greater in the medium body than in the small body phantom and 1.3–1.5 times greater in the large body than in the small body phantom. RMS errors of the calculated volume fractions of red marrow within 2 × 2 segmented subregions of the ROIs were 1.6–1.9 times greater than for no segmentation, and RMS errors for 3 × 3 segmented subregions were 2.3–2.7 times greater than those for no segmentation. Increasing the dose by a factor of 2 reduced the RMS errors of all constituent volume fractions by an average factor of 1.40 ± 0.29 for all segmentation schemes and body phantom sizes; increasing the dose by a factor of 4 reduced those RMS errors by an average factor of 1.71 ± 0.25. Results for external calibrations exhibited much larger RMS errors than size matched internal calibration. Use of an average body size external-to-internal calibration correction factor reduced the errors to closer to those for internal calibration. RMS errors of less than 30% or about 0.01 for the bone and 0.1 for the red marrow volume fractions would likely be satisfactory for human studies. Such accuracies were achieved for 3 × 3 segmentation of 5 mm slice images for: (a) internal calibration with 4 times dose for all size body phantoms, (b) internal calibration with 2 times dose for the small and medium size body phantoms, and (c) corrected external calibration with 4 times dose and all size body phantoms. Conclusions: Phantom studies are promising and demonstrate the potential to use dual energy quantitative CT to estimate the spatial distributions of red marrow and bone within the vertebral spongiosa.« less
Goodsitt, Mitchell M.; Shenoy, Apeksha; Shen, Jincheng; Howard, David; Schipper, Matthew J.; Wilderman, Scott; Christodoulou, Emmanuel; Chun, Se Young; Dewaraja, Yuni K.
2014-01-01
Purpose: To evaluate a three-equation three-unknown dual-energy quantitative CT (DEQCT) technique for determining region specific variations in bone spongiosa composition for improved red marrow dose estimation in radionuclide therapy. Methods: The DEQCT method was applied to 80/140 kVp images of patient-simulating lumbar sectional body phantoms of three sizes (small, medium, and large). External calibration rods of bone, red marrow, and fat-simulating materials were placed beneath the body phantoms. Similar internal calibration inserts were placed at vertebral locations within the body phantoms. Six test inserts of known volume fractions of bone, fat, and red marrow were also scanned. External-to-internal calibration correction factors were derived. The effects of body phantom size, radiation dose, spongiosa region segmentation granularity [single (∼17 × 17 mm) region of interest (ROI), 2 × 2, and 3 × 3 segmentation of that single ROI], and calibration method on the accuracy of the calculated volume fractions of red marrow (cellularity) and trabecular bone were evaluated. Results: For standard low dose DEQCT x-ray technique factors and the internal calibration method, the RMS errors of the estimated volume fractions of red marrow of the test inserts were 1.2–1.3 times greater in the medium body than in the small body phantom and 1.3–1.5 times greater in the large body than in the small body phantom. RMS errors of the calculated volume fractions of red marrow within 2 × 2 segmented subregions of the ROIs were 1.6–1.9 times greater than for no segmentation, and RMS errors for 3 × 3 segmented subregions were 2.3–2.7 times greater than those for no segmentation. Increasing the dose by a factor of 2 reduced the RMS errors of all constituent volume fractions by an average factor of 1.40 ± 0.29 for all segmentation schemes and body phantom sizes; increasing the dose by a factor of 4 reduced those RMS errors by an average factor of 1.71 ± 0.25. Results for external calibrations exhibited much larger RMS errors than size matched internal calibration. Use of an average body size external-to-internal calibration correction factor reduced the errors to closer to those for internal calibration. RMS errors of less than 30% or about 0.01 for the bone and 0.1 for the red marrow volume fractions would likely be satisfactory for human studies. Such accuracies were achieved for 3 × 3 segmentation of 5 mm slice images for: (a) internal calibration with 4 times dose for all size body phantoms, (b) internal calibration with 2 times dose for the small and medium size body phantoms, and (c) corrected external calibration with 4 times dose and all size body phantoms. Conclusions: Phantom studies are promising and demonstrate the potential to use dual energy quantitative CT to estimate the spatial distributions of red marrow and bone within the vertebral spongiosa. PMID:24784380
Challenges in Accommodating Volume Change of Si Anodes for Li-Ion Batteries
Ko, Minseong; Chae, Sujong; Cho, Jaephil
2015-01-01
Si has been considered as a promising alternative anode for next-generation Li-ion batteries (LIBs) because of its high theoretical energy density, relatively low working potential, and abundance in nature. However, Si anodes exhibit rapid capacity decay and an increase in the internal resistance, which are caused by the large volume changes upon Li insertion and extraction. This unfortunately limits their practical applications. Therefore, managing the total volume change remains a critical challenge for effectively alleviating the mechanical fractures and instability of solid-electrolyte-interphase products. In this regard, we review the recent progress in volume-change-accommodating Si electrodes and investigate their ingenious structures with significant improvements in the battery performance, including size-controlled materials, patterned thin films, porous structures, shape-preserving shell designs, and graphene composites. These representative approaches potentially overcome the large morphologic changes in the volume of Si anodes by securing the strain relaxation and structural integrity in the entire electrode. Finally, we propose perspectives and future challenges to realize the practical application of Si anodes in LIB systems. PMID:27525208
Recent experience with design and manufacture of cine lenses
NASA Astrophysics Data System (ADS)
Thorpe, Michael D.; Dalzell, Kristen E.
2015-09-01
Modern cine lenses require a high degree of aberration correction over a large and ever expanding image size. At low to medium volume production levels, these highly corrected designs also require a workable tolerance set and compensation scheme for successful manufacture. In this paper we discuss the design and manufacture of cine lenses with reference to current designs both internal and in the patent literature and some experience in design, tolerancing and manufacturing these lenses in medium volume production.
Toy, S J; Newfield, M J
2010-04-01
Hitchhiker organisms have been known since the earliest days of international travel, but changes in global trade mean that there are more now than ever before. They include a number of serious invasive species and are among the most difficult of quarantine problems to manage. Invasive animals transported as hitchhikers, other than plant pests, fall largely outside the international frameworks for biosecurity risk analysis. However, this is not necessarily a barrierto either risk analysis or effective management. While there are a number of challenges in managing hitchhiker organisms, the risk analysis tools that are needed already exist. However, opening up access to appropriate information, increasing international cooperation and developing new biosecurity treatments suitable for large-volume pathways will enable significant improvements.
Strain Monitoring of Flexible Structures
NASA Technical Reports Server (NTRS)
Litteken, Douglas A.
2017-01-01
One of the biggest challenges facing NASA's deep space exploration goals is structural mass. A long duration transit vehicle on a journey to Mars, for example, requires a large internal volume for cargo, supplies and crew support. As with all space structures, a large pressure vessel is not enough. The vehicle also requires thermal, micro-meteoroid, and radiation protection, a navigation and control system, a propulsion system, and a power system, etc. As vehicles get larger, their associated systems also get larger and more complex. These vehicles require larger lift capacities and force the mission to become extremely costly. In order to build large volume habitable vehicles, with only minimal increases in launch volume and mass, NASA is developing lightweight structures. Lightweight structures are made from non-metallic materials including graphite composites and high strength fabrics and could provide similar or better structural capability than metals, but with significant launch volume and mass savings. Fabric structures specifically, have been worked by NASA off and on since its inception, but most notably in the 1990's with the TransHAB program. These TransHAB developed structures use a layered material approach to form a pressure vessel with integrated thermal and micro-meteoroid and orbital debris (MMOD) protection. The flexible fabrics allow the vessel to be packed in a small volume during launch and expand into a much larger volume once in orbit. NASA and Bigelow Aerospace recently installed the first human-rated inflatable module on the International Space Station (ISS), known as the Bigelow Expandable Activity Module (BEAM) in May of 2016. The module provides a similar internal volume to that of an Orbital ATK Cygnus cargo vehicle, but with a 77% launch volume savings. As lightweight structures are developed, testing methods are vital to understanding their behavior and validating analytical models. Common techniques can be applied to fabric materials, such as tensile testing, fatigue testing, and shear testing, but common measurement techniques cannot be used on fabric. Measuring strain in a material and during a test is a critical parameter for an engineer to monitor the structure during the test and correlate to an analytical model. The ability to measure strain in fabric structures is a challenge for NASA. Foil strain gauges, for example, are commonplace on metallic structures testing, but are extremely difficult to interface with a fabric substrate. New strain measuring techniques need to be developed for use with fabric structures. This paper investigates options for measuring strain in fabric structures for both ground testing and in-space structural health monitoring. It evaluates current commercially available options and outlines development work underway to build custom measurement solutions for NASA's fabric structures.
The Horizon Report: 2010 Museum Edition
ERIC Educational Resources Information Center
Johnson, L.; Witchey, H.; Smith, R.; Levine, A.; Haywood, K.
2010-01-01
The internationally recognized series of "Horizon Reports" is part of the New Media Consortium's Horizon Project, a comprehensive research venture established in 2002 that identifies and describes emerging technologies likely to have a large impact over the coming five years on a variety of sectors around the globe. This volume, the "2010 Horizon…
ERIC Educational Resources Information Center
Johnson, L.; Smith, R.; Willis, H.; Levine, A.; Haywood, K.
2011-01-01
The internationally recognized series of "Horizon Reports" is part of the New Media Consortium's Horizon Project, a comprehensive research venture established in 2002 that identifies and describes emerging technologies likely to have a large impact over the coming five years on a variety of sectors around the globe. This volume, the "2011 Horizon…
The Horizon Report: 2010 Australia-New Zealand Edition
ERIC Educational Resources Information Center
Johnson, L.; Smith, R.; Levine, A.; Haywood, K.
2010-01-01
The internationally recognized series of "Horizon Reports" is part of the New Media Consortium's Horizon Project, a comprehensive research venture established in 2002 that identifies and describes emerging technologies likely to have a large impact over the coming five years on a variety of sectors around the globe. This volume, the…
Curvilinear steel elements in load-bearing structures of high-rise building spatial frames
NASA Astrophysics Data System (ADS)
Ibragimov, Alexander; Danilov, Alexander
2018-03-01
The application of curvilinear elements in load-bearing metal structures of high-rise buildings supposes ensuring of their bearing capacity and serviceability. There may exist a great variety of shapes and orientations of such structural elements. In particular, it may be various flat curves of an open or closed oval profile such as circular or parabolic arch or ellipse. The considered approach implies creating vast internal volumes without loss in the load-bearing capacity of the frame. The basic concept makes possible a wide variety of layout and design solutions. The presence of free internal spaces of large volume in "skyscraper" type buildings contributes to resolving a great number of problems, including those of communicative nature. The calculation results confirm the basic assumptions.
Liu, Chenbin; Schild, Steven E; Chang, Joe Y; Liao, Zhongxing; Korte, Shawn; Shen, Jiajian; Ding, Xiaoning; Hu, Yanle; Kang, Yixiu; Keole, Sameer R; Sio, Terence T; Wong, William W; Sahoo, Narayan; Bues, Martin; Liu, Wei
2018-06-01
To investigate how spot size and spacing affect plan quality, robustness, and interplay effects of robustly optimized intensity modulated proton therapy (IMPT) for lung cancer. Two robustly optimized IMPT plans were created for 10 lung cancer patients: first by a large-spot machine with in-air energy-dependent large spot size at isocenter (σ: 6-15 mm) and spacing (1.3 σ), and second by a small-spot machine with in-air energy-dependent small spot size (σ: 2-6 mm) and spacing (5 mm). Both plans were generated by optimizing radiation dose to internal target volume on averaged 4-dimensional computed tomography scans using an in-house-developed IMPT planning system. The dose-volume histograms band method was used to evaluate plan robustness. Dose evaluation software was developed to model time-dependent spot delivery to incorporate interplay effects with randomized starting phases for each field per fraction. Patient anatomy voxels were mapped phase-to-phase via deformable image registration, and doses were scored using in-house-developed software. Dose-volume histogram indices, including internal target volume dose coverage, homogeneity, and organs at risk (OARs) sparing, were compared using the Wilcoxon signed-rank test. Compared with the large-spot machine, the small-spot machine resulted in significantly lower heart and esophagus mean doses, with comparable target dose coverage, homogeneity, and protection of other OARs. Plan robustness was comparable for targets and most OARs. With interplay effects considered, significantly lower heart and esophagus mean doses with comparable target dose coverage and homogeneity were observed using smaller spots. Robust optimization with a small spot-machine significantly improves heart and esophagus sparing, with comparable plan robustness and interplay effects compared with robust optimization with a large-spot machine. A small-spot machine uses a larger number of spots to cover the same tumors compared with a large-spot machine, which gives the planning system more freedom to compensate for the higher sensitivity to uncertainties and interplay effects for lung cancer treatments. Copyright © 2018 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hobbs, Michael L.; Kaneshige, Michael J.; Erikson, William W.
In this study, we have made reasonable cookoff predictions of large-scale explosive systems by using pressure-dependent kinetics determined from small-scale experiments. Scale-up is determined by properly accounting for pressure generated from gaseous decomposition products and the volume that these reactive gases occupy, e.g. trapped within the explosive, the system, or vented. The pressure effect on the decomposition rates has been determined for different explosives by using both vented and sealed experiments at low densities. Low-density explosives are usually permeable to decomposition gases and can be used in both vented and sealed configurations to determine pressure-dependent reaction rates. In contrast, explosivesmore » that are near the theoretical maximum density (TMD) are not as permeable to decomposition gases, and pressure-dependent kinetics are difficult to determine. Ignition in explosives at high densities can be predicted by using pressure-dependent rates determined from the low-density experiments as long as gas volume changes associated with bulk thermal expansion are also considered. In the current work, cookoff of the plastic-bonded explosives PBX 9501 and PBX 9502 is reviewed and new experimental work on LX-14 is presented. Reactive gases are formed inside these heated explosives causing large internal pressures. The pressure is released differently for each of these explosives. For PBX 9501, permeability is increased and internal pressure is relieved as the nitroplasticizer melts and decomposes. Internal pressure in PBX 9502 is relieved as the material is damaged by cracks and spalling. For LX-14, internal pressure is not relieved until the explosive thermally ignites. The current paper is an extension of work presented at the 26th ICDERS symposium [1].« less
A notable difference between ideal gas and infinite molar volume limit of van der Waals gas
NASA Astrophysics Data System (ADS)
Liu, Q. H.; Shen, Y.; Bai, R. L.; Wang, X.
2010-05-01
The van der Waals equation of state does not sufficiently represent a gas unless a thermodynamic potential with two proper and independent variables is simultaneously determined. The limiting procedures under which the behaviour of the van der Waals gas approaches that of an ideal gas are letting two van der Waals coefficients be zero rather than letting the molar volume become infinitely large; otherwise, the partial derivative of internal energy with respect to pressure at a fixed temperature does not vanish.
Education in the World. International Yearbook of Education: Volume XL--1988.
ERIC Educational Resources Information Center
Faraj, Abdulatif Hussein
This report is designed to familarize educators with systems of education in a selected sample of countries and with the development that has occurred in these systems between 1984 and 1986. The information presented is drawn largely from national reports and questionnaire reports summarized by member states of UNESCO at the International…
NASA Technical Reports Server (NTRS)
2001-01-01
The Microgravity Science Glovebox is being developed by the European Space Agency and NASA to provide a large working volume for hands-on experiments aboard the International Space Station. Scientists will use the MSG to carry out multidisciplinary studies in combustion science, fluid physics and materials science. The MSG is managed by NASA's Marshall Space Flight Center. (Credit: NASA/Marshall)
Due to large-volume commercial uses as an intermediate and for water disinfection, chlorine (Cl2) is an important hazardous air pollutant (HAP). Inhaled Cl2 causes irritant effects in the respiratory tract. We conducted studies to characterize determinants...
2001-05-31
The Microgravity Science Glovebox is being developed by the European Space Agency and NASA to provide a large working volume for hands-on experiments aboard the International Space Station. Scientists will use the MSG to carry out multidisciplinary studies in combustion science, fluid physics and materials science. The MSG is managed by NASA's Marshall Space Flight Center. (Credit: NASA/Marshall)
Cradle-to-grave life cycle assessment of syngas electricity from woody biomass residues
Hongmei Gu; Richard Bergman
2017-01-01
Forest restoration and fire suppression activities in the western United States have resulted in large volumes of low-to-no value residues. An environmental assessment would enable greater use while maintaining environmental sustainability of these residues for energy products. One internationally accepted sustainable metric tool that can assess environmental impacts...
The NMC Horizon Report: 2012 Higher Education Edition
ERIC Educational Resources Information Center
Johnson, L.; Adams, S.; Cummins, M.
2012-01-01
The internationally recognized "NMC Horizon Report" series and regional "NMC Technology Outlooks" are part of the NMC Horizon Project, a comprehensive research venture established in 2002 that identifies and describes emerging technologies likely to have a large impact over the coming five years in education around the globe. This volume, the "NMC…
Chambers, Brian; Chambers, Jayne; Churilov, Leonid; Cameron, Heather; Macdonell, Richard
2014-09-01
We evaluated internal jugular vein and vertebral vein volume flow using ultrasound, in patients with clinically isolated syndrome or mild multiple sclerosis and controls, to determine whether volume flow was different between the two groups. In patients and controls, internal jugular vein volume flow increased from superior to inferior segments, consistent with recruitment from collateral veins. Internal jugular vein and vertebral vein volume flow were greater on the right in supine and sitting positions. Internal jugular vein volume flow was higher in the supine posture. Vertebral vein volume flow was higher in the sitting posture. Regression analyses of cube root transformed volume flow data, adjusted for supine/sitting, right/left and internal jugular vein/vertebral vein, revealed no significant difference in volume flow in patients compared to controls. Our findings further refute the concept of venous obstruction as a causal factor in the pathogenesis of multiple sclerosis. Control volume flow data may provide useful normative reference values. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Canaud, Bernard; Barbieri, Carlo; Marcelli, Daniele; Bellocchio, Francesco; Bowry, Sudhir; Mari, Flavio; Amato, Claudia; Gatti, Emanuele
2015-01-01
Online hemodiafiltration (OL-HDF), the most efficient renal replacement therapy, enables enhanced removal of small and large uremic toxins by combining diffusive and convective solute transport. Randomized controlled trials on prevalent chronic kidney disease (CKD) patients showed improved patient survival with high-volume OL-HDF, underlining the effect of convection volume (CV). This retrospective international study was conducted in a large cohort of incident CKD patients to determine the CV threshold and range associated with survival advantage. Data were extracted from a cohort of adult CKD patients treated by post-dilution OL-HDF over a 101-month period. In total, 2293 patients with a minimum of 2 years of follow-up were analyzed using advanced statistical tools, including cubic spline analyses for determination of the CV range over which a survival increase was observed. The relative survival rate of OL-HDF patients, adjusted for age, gender, comorbidities, vascular access, albumin, C-reactive protein, and dialysis dose, was found to increase at about 55 l/week of CV and to stay increased up to about 75 l/week. Similar analysis of pre-dialysis β2-microglobin (marker of middle-molecule uremic toxins) concentrations found a nearly linear decrease in marker concentration as CV increased from 40 to 75 l/week. Analysis of log C-reactive protein levels showed a decrease over the same CV range. Thus, a convection dose target based on convection volume should be considered and needs to be confirmed by prospective trials as a new determinant of dialysis adequacy. PMID:25945407
Horká, Marie; Karásek, Pavel; Roth, Michal; Šlais, Karel
2017-05-01
In this work, single-piece fused silica capillaries with two different internal diameter segments featuring different inner surface roughness were prepared by new etching technology with supercritical water and used for volume coupling electrophoresis. The concept of separation and online pre-concentration of analytes in high conductivity matrix is based on the online large-volume sample pre-concentration by the combination of transient isotachophoretic stacking and sweeping of charged proteins in micellar electrokinetic chromatography using non-ionogenic surfactant. The modified surface roughness step helped to the significant narrowing of the zones of examined analytes. The sweeping and separating steps were accomplished simultaneously by the use of phosphate buffer (pH 7) containing ethanol, non-ionogenic surfactant Brij 35, and polyethylene glycol (PEG 10000) after sample injection. Sample solution of a large volume (maximum 3.7 μL) dissolved in physiological saline solution was injected into the wider end of capillary with inlet inner diameter from 150, 185 or 218 μm. The calibration plots were linear (R 2 ∼ 0.9993) over a 0.060-1 μg/mL range for the proteins used, albumin and cytochrome c. The peak area RSDs from at least 20 independent measuremens were below 3.2%. This online pre-concentration technique produced a more than 196-fold increase in sensitivity, and it can be applied for detection of, e.g. the presence of albumin in urine (0.060 μg/mL). © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Prosthetic occlusive device for an internal passageway
NASA Technical Reports Server (NTRS)
Tenney, J. B., Jr. (Inventor)
1983-01-01
An occlusive device is disclosed for surgical implant to occlude the lumen of an internal organ. The device includes a cuff having a backing collar and two isolated cuff chambers. The fluid pressure of one chamber is regulated by a pump/valve reservoir unit. The other chamber is unregulated in pressure but its fluid volume is adjusted by removing or adding fluid to a septum/reservoir by means of a hypodermic needle. Pressure changes are transmitted between the two cuff chambers via faying surfaces which are sufficiently large in contact area and thin as to transmit pressure generally without attenuation. By adjusting the fluid volume of the septum, the operating pressure of the device may be adjusted to accommodate tubular organs of different diameter sizes as well as to compensate for changes in the organ following implant without reoperation.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-03
... firms that control the handling of a large volume of customer and proprietary order flow. Given the... more closely aligns with current data consumption and will reduce costs for the Exchange's customers... Data service to its customers or to distribute the data internally. In addition, the Exchange will...
A NASTRAN Model of a Large Flexible Swing-Wing Bomber. Volume 1: NASTRAN Model Plane
NASA Technical Reports Server (NTRS)
Mock, W. D.
1982-01-01
A review was conducted of B-1 aircraft no. 2 (A/C-2) internal loads models to determine the minimum model complexity necessary to fulfill all of the airloads research study objectives. Typical model sizings were tabulated at selected vehicle locations, and scale layouts were prepared of the NASTRAN structural analysis model.
Large N phase transitions and the fate of small Schwarzschild-AdS black holes
NASA Astrophysics Data System (ADS)
Yaffe, Laurence G.
2018-01-01
Sufficiently small Schwarzschild-AdS black holes in asymptotically global AdS5×S5 spacetime are known to become dynamically unstable toward deformation of the internal S5 geometry. The resulting evolution of such an unstable black hole is related, via holography, to the dynamics of supercooled plasma which has reached the limit of metastability in maximally supersymmetric large-N Yang-Mills theory on R ×S3. Puzzles related to the resulting dynamical evolution are discussed, with a key issue involving differences between the large-N limit in the dual field theory and typical large volume thermodynamic limits.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oehmigen, Steffen; Ambos, Frank
There are a lot of metallic large components for the transport of radioactive waste in Germany. Some of these large components like for example the Castor S1 with 82 Mg are so old, that the transport via streets is not possible because the permission is not valid anymore. The application for a new permission is economically not reasonable. Out of this reason the large components need to be decontaminated and recycled to use them again in the economic cycle. Decontamination of large components by cleaning/removing the surface for example with beam technology is a very time-consuming release procedure. Manufacturing amore » specialized machine for decontamination and creation of a new surface was the intention of this project. The objective was to save interim storage and final repository volume and costs as well as developing a process that is nationally and internationally usable. 90% of the volume/mass of waste could be released and therefore possibly re-used. (authors)« less
Photovoltaic concentrator assembly with optically active cover
Plesniak, Adam P
2014-01-21
A photovoltaic concentrator assembly that includes a housing that defines an internal volume and includes a rim, wherein the rim defines an opening into the internal volume, a photovoltaic cell positioned in the internal volume, and an optical element that includes an optically active body and a flange extending outward from the body, wherein the flange is sealingly engaged with the rim of the housing to enclose the internal volume.
Complete 360° circumferential SSOCT gonioscopy of the iridocorneal angle
NASA Astrophysics Data System (ADS)
McNabb, Ryan P.; Kuo, Anthony N.; Izatt, Joseph A.
2014-02-01
The ocular iridocorneal angle is generally an optically inaccessible area when viewed directly through the cornea due to the high angle of incidence required and the large index of refraction difference between air and cornea (nair = 1.000 and ncornea = 1.376) resulting in total internal reflection. Gonioscopy allows for viewing of the angle by removing the aircornea interface through the use of a special contact lens on the eye. Gonioscopy is used clinically to visualize the angle directly but only en face. Optical coherence tomography (OCT) has been used to image the angle and deeper structures via an external approach. Typically, this imaging technique is performed by utilizing a conventional anterior segment OCT scanning system. However, instead of imaging the apex of the cornea, either the scanner or the subject is tilted such that the corneoscleral limbus is orthogonal to the optical axis of the scanner requiring multiple volumes to obtain complete circumferential coverage of the ocular angle. We developed a novel gonioscopic OCT (GOCT) system that images the entire ocular angle within a single volume via an "internal" approach through the use of a custom radially symmetric gonioscopic contact lens. We present, to our knowledge, the first complete 360° circumferential volumes of the iridocorneal angle from a direct, internal approach.
Semiconductor radiation detector with internal gain
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iwanczyk, Jan; Patt, Bradley E.; Vilkelis, Gintas
An avalanche drift photodetector (ADP) incorporates extremely low capacitance of a silicon drift photodetector (SDP) and internal gain that mitigates the surface leakage current noise of an avalanche photodetector (APD). The ADP can be coupled with scintillators such as CsI(Tl), NaI(Tl), LSO or others to form large volume scintillation type gamma ray detectors for gamma ray spectroscopy, photon counting, gamma ray counting, etc. Arrays of the ADPs can be used to replace the photomultiplier tubes (PMTs) used in conjunction with scintillation crystals in conventional gamma cameras for nuclear medical imaging.
Wang, Xiao-Yan; Zong, Huan-Tao; Zhang, Yong
2016-01-01
Prostate artery embolization (PAE) is emerging and is a promising minimally invasive therapy that improves lower urinary tract symptoms (LUTS) related to benign prostatic hyperplasia (BPH). The purpose of this article was to evaluate the efficacy and safety of PAE on LUTS related to BPH. A literature review was performed to identify all published articles of PAE for BPH. The sources included MEDLINE, EMBASE and Cochrane Library from 1980 to 2016. A systematic review and meta-analysis was conducted. The outcome measurements were combined by calculating the mean difference with 95% confidence interval. Statistical analysis was carried out using Review Manager 5.3.0. Twelve studies involving 840 participants were included. Compared with baseline, the International Index of Erectile Function (IIEF-5; International Prostate Symptom Score) scores, the quality of life scores, peak urinary flow rate ( Q max ) and postvoid residual volume all had significant improvements during the 24-month follow-up (all P <0.00001). Both prostate volume (PV) and prostate-specific antigen had significant decrease during the 12-month follow-up ( P <0.00001 and P =0.005, respectively), except postoperative 24 months ( P =0.47 and P =0.32, respectively). The IIEF-5 short form scores had significant increase at postoperative 6 months ( P =0.002) and 12 months ( P <0.0001), except postoperative 1 month ( P =0.23) and 24 months ( P =0.21). For large volume (PV ≥80 mL) BPH, the results were similar. There were no life-threatening complications. PAE is an effective, safe and well-tolerable treatment for LUTS related to BPH, including large volume (PV ≥80 mL) BPH, with a good short-term follow-up. Studies with large number of cases and longer follow-up time are needed to validate our results.
Lunte, Kaspars; Cordier-Lassalle, Thierry; Keravec, Joel
2015-04-01
Many countries have limited experience of securing the best prices for drugs and have little negotiating power. This is particularly true for the complex, lengthy and expensive regimens used to treat multidrug-resistant tuberculosis. The Stop TB Partnership's Global Drug Facility is dedicated to improving worldwide access to antituberculosis medicines and diagnostic techniques that meet international quality standards. The Global Drug Facility is able to secure price reductions through competitive tendering among prequalified drug manufacturers and by consolidating orders to achieve large purchase volumes. Consolidating the market in this way increases the incentives for suppliers of quality-assured medicines. In 2013 the Global Drug Facility reduced the price of the second-line drugs it supplies for multidrug-resistant tuberculosis: the overall cost of the longest and most expensive treatment regimen for a patient decreased by 26% - from 7890 United States dollars (US$) in 2011 to US$ 5822 in 2013. The price of treatment for multidrug-resistant tuberculosis supplied by the Global Drug Facility was reduced by consolidating orders to achieve large purchase volumes, by international, competitive bidding and by the existence of donor-funded medicine stockpiles. The rise in the number of suppliers of internationally quality-assured drugs was also important. The savings achieved from lower drug costs could be used to increase the number of patients on high-quality treatment.
International Relations. International Perspectives on Higher Education Research. Volume 3
ERIC Educational Resources Information Center
Tight, Malcolm, Ed.
2005-01-01
This is the third volume of International Perspectives on Higher Education Research, a series which aims to feature something of the variety of research being undertaken into higher education systems and issues outside of North America. The theme of this volume is International Relations, or how students, academics, universities and higher…
Study of a Large Prototype TPC for the ILC using Micro-Pattern Gas Detectors
NASA Astrophysics Data System (ADS)
Münnich, A.; LCTPC Collaboration
2016-04-01
In the last decade, R&D for detectors for the future International Linear Collider (ILC) has been performed by the community. The International Large Detector (ILD) is one of two detector concepts at the ILC. Its tracking system consists of a Si vertex detector, forward tracking disks and a large volume Time Projection Chamber (TPC). Within the LCTPC collaboration, a Large Prototype (LP) TPC has been built as a demonstrator. Its endplate is able to house up to seven identical modules with Micro-Pattern Gas Detectors (MPGD) amplification. Recently, the LP has been equipped with resistive anode Micromegas (MM) or Gas Electron Multiplier (GEM) modules. Both the MM and GEM technologies have been studied with an electron beam up to 6 GeV in a 1 Tesla solenoid magnet. After introducing the current R&D status, recent results will be presented including field distortions, ion gating and spatial resolution as well as future plans of the LCTPC R&D.
Generalized Roche potential for misaligned binary systems - Properties of the critical lobe
NASA Technical Reports Server (NTRS)
Avni, Y.; Schiller, N.
1982-01-01
The paper considers the Roche potential for binary systems where the stellar rotation axis is not aligned with the orbital revolution axis. It is shown that, as the degree of misalignment varies, internal Lagrangian points and external Lagrangian points may switch their roles. A systematic method to identify the internal Lagrangian point and to calculate the volume of the critical lobe is developed, and numerical results for a wide range of parameters of binary systems with circular orbits are presented. For binary systems with large enough misalignment, discrete changes occur in the topological structure of the equipotential surfaces as the orbital phase varies. The volume of the critical lobe has minima, as a function of orbital phase, at the two instances when the secondary crosses the equatorial plane of the primary. In semidetached systems, mass transfer may be confined to the vicinity of these two instances.
ERIC Educational Resources Information Center
Huang, Haigen; Sebastian, James
2015-01-01
Since the publication of the Coleman report in 1966, research on the role of schools in influencing student achievement relative to the role of family background has generated considerable interest and controversy. A large volume of international and comparative research has also been devoted to studying school effects on student achievement.…
ERIC Educational Resources Information Center
Fase, Willem, Ed.; And Others
In many respects, the state of minority language reflects the dynamics of the society at large. At this time, many minority languages are threatened by modernization and urbanization, although others find support in new regional autonomy and movements toward cultural preservation. The 17 chapters of this collection describe the status of a number…
26 CFR 1.141-10 - Coordination with volume cap. [Reserved
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Coordination with volume cap. [Reserved] 1.141-10 Section 1.141-10 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED....141-10 Coordination with volume cap. [Reserved] ...
Cryo-Compression System in a 3000 Ton Multi-Anvil Press
NASA Astrophysics Data System (ADS)
Secco, R. A.; Yong, W.
2016-12-01
Most large volume high pressure devices are capable of high temperature experiments that are typically achieved by using localized resistive heating of a metal foil, graphite or ceramic sleeve inside a thermally insulated sample volume in a high pressure cell. Low temperatures at high pressures are needed for physical property studies of materials that comprise planetary bodies in the outer solar system. However, low temperatures are more difficult to achieve mainly because the massive steel components of the press, which are in good thermal contact with each other under high load, act as large heat reservoirs and pathways that encumber the removal of heat from the pressure cell. We describe a new custom-designed system under development for a 3000 ton multi-anvil press to reach temperatures below 295K at high pressures. The system was designed to remove heat selectively and conductively from the sample volume through six of the eight WC cubes in direct contact with the octahedral pressure cell. Cooling fins made of Cu are sandwiched between, and in thermal contact with, neighboring anvil faces and are each connected to a dedicated Cu heat exchanger chamber through which liquid nitrogen flows. The chamber internal geometry consists of either square pillars that double the internal surface area of the rectangular parallelepiped enclosed volume or continuous walls separated by valleys. Gas from each chamber is vented to the lab through an exhaust pipe. High pressure results will be presented of several temperature monitoring points in the center of the pressure cell and on the surfaces of the WC cubes and steel wedges which recorded the time-dependent cooling progress. Temperature stability tests will also be presented.
N-flation with hierarchically light axions in string compactifications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cicoli, Michele; Dutta, Koushik; Maharana, Anshuman, E-mail: mcicoli@ictp.it, E-mail: koushik.dutta@saha.ac.in, E-mail: anshumanmaharana@hri.res.in
2014-08-01
We propose a possible embedding of axionic N-flation in type IIB string compactifications where most of the Kähler moduli are stabilised by perturbative effects, and so are hierarchically heavier than the corresponding N>> 1 axions whose collective dynamics drives inflation. This is achieved in the framework of the LARGE Volume Scenario for moduli stabilisation. Our set-up can be used to realise a model of either large field inflation or quintessence, just by varying the volume of the internal space which controls the scale of the axionic potential. Both cases predict a very high scale of supersymmetry breaking. A fully explicit stringymore » embedding of N-flation would require control over dangerous back-reaction effects due to a large number of species. A viable reheating of the Standard Model degrees of freedom can be achieved after the end of inflation due to the perturbative decay of the N light axions which drive inflation.« less
Lee, J M; Han, J K; Kim, S H; Lee, J Y; Shin, K S; Choi, B I
2005-08-01
To determine optimal parameters for bipolar radiofrequency ablation (RFA) using perfusion-cooled electrodes to create a large ablation volume in ex vivo bovine liver. Three sets of RF experiments were performed using a 200-Watt generator and two 15-gauge perfusion-cooled or internally cooled electrodes in ex vivo bovine livers. In the first set of experiments, to find the ideal inter-electrode distance for creating large coagulation necrosis, 30 ablation lesions were created by bipolar RFAs at inter-electrode spacings of 3 cm, 4 cm, and 5 cm. In the second set of experiments, to explore the ideal duration of RF application, bipolar RFAs were performed for 10 min and 20 min. In the first and second experiments, 10 lesions were made for each condition with infusion of 6% hypertonic saline (HS) at 2 ml/min. In the third set of experiments, 10 ablation lesions were created by bipolar RFAs using internally cooled electrodes without HS infusion. The mean volume of those ablation lesions was then compared to that of the lesions created by bipolar RFA using perfusion-cooled electrodes in the second experiments. Tissue impedance, dimension, and shape of the ablated areas were compared in each condition. In the first set of experiments, bipolar RFA created a homogeneous oval or spherical-shaped ablation area between the electrodes at 3-5 cm spacing, but showed a more spherical-shaped lesion at 3 cm inter-electrode spacing than at 4 cm and 5 cm spacing. In the second set of experiments, RF energy delivered for 20 min created a larger dimension of coagulation necrosis than energy delivered for 10 min: 107.6 +/- 34 cm3 versus 59.5 +/- 27 cm3 (P<0.05). In addition, the mean volume of ablation regions obtained with bipolar RFA using the internally cooled electrode was 47.5+/- 17 cm3, which was significantly less than that with bipolar RFA using perfusion-cooled electrodes (P <0.05). Bipolar RFA using perfusion-cooled electrodes achieves homogeneous areas of coagulation necrosis between two electrodes, preferably at 3 or 4 cm inter-electrode distance for 20 min, and is better in creating large coagulation necrosis than bipolar RFA using internally cooled electrodes.
[Target volume margins for lung cancer: internal target volume/clinical target volume].
Jouin, A; Pourel, N
2013-10-01
The aim of this study was to carry out a review of margins that should be used for the delineation of target volumes in lung cancer, with a focus on margins from gross tumour volume (GTV) to clinical target volume (CTV) and internal target volume (ITV) delineation. Our review was based on a PubMed literature search with, as a cornerstone, the 2010 European Organisation for Research and Treatment of Cancer (EORTC) recommandations by De Ruysscher et al. The keywords used for the search were: radiotherapy, lung cancer, clinical target volume, internal target volume. The relevant information was categorized under the following headings: gross tumour volume definition (GTV), CTV-GTV margin (first tumoural CTV then nodal CTV definition), in field versus elective nodal irradiation, metabolic imaging role through the input of the PET scanner for tumour target volume and limitations of PET-CT imaging for nodal target volume definition, postoperative radiotherapy target volume definition, delineation of target volumes after induction chemotherapy; then the internal target volume is specified as well as tumoural mobility for lung cancer and respiratory gating techniques. Finally, a chapter is dedicated to planning target volume definition and another to small cell lung cancer. For each heading, the most relevant and recent clinical trials and publications are mentioned. Copyright © 2013. Published by Elsevier SAS.
NASA Astrophysics Data System (ADS)
Goharshadi, Elaheh K.; Morsali, Ali; Mansoori, G. Ali
2007-01-01
Isotherms of experimental data of internal pressure of dense fluids versus molar volume, Vm are shown to have each a maximum point at a Vmax below the critical molar volume. In this study, we investigated the role of attractive and repulsive intermolecular energies on this behavior using a molecular dynamics simulation technique. In the simulation, we choose the Lennard-Jones (LJ) intermolecular potential energy function. The LJ potential is known to be an effective potential representing a statistical average of the true pair and many-body interactions in simple molecular systems. The LJ potential function is divided into attractive and repulsive parts. MD calculations have produced internal energy, potential energy, transitional kinetic energy, and radial distribution function (RDF) for argon at 180 K and 450 K using LJ potential, LJ repulsive, and LJ attractive parts. It is shown that the LJ potential function is well capable of predicting the inflection point in the internal energy-molar volume curve as well as maximum point in the internal pressure-molar volume curve. It is also shown that at molar volumes higher than Vmax, the attractive forces have strong influence on determination of internal energy and internal pressure. At volumes lower than Vmax, neither repulsive nor attractive forces are dominating. Also, the coincidence between RDFs resulting from LJ potential and repulsive parts of LJ potential improves as molar volume approaches Vmax from high molar volumes. The coincidence becomes complete at Vmax ⩾ V.
Subsystems component definitions summary program
NASA Technical Reports Server (NTRS)
Scott, A. Don; Thomas, Carolyn C.; Simonsen, Lisa C.; Hall, John B., Jr.
1991-01-01
A computer program, the Subsystems Component Definitions Summary (SUBCOMDEF), was developed to provide a quick and efficient means of summarizing large quantities of subsystems component data in terms of weight, volume, resupply, and power. The program was validated using Space Station Freedom Program Definition Requirements Document data for the internal and external thermal control subsystem. Once all component descriptions, unit weights and volumes, resupply, and power data are input, the user may obtain a summary report of user-specified portions of the subsystem or of the entire subsystem as a whole. Any combination or all of the parameters of wet and dry weight, wet and dry volume, resupply weight and volume, and power may be displayed. The user may vary the resupply period according to individual mission requirements, as well as the number of hours per day power consuming components operate. Uses of this program are not limited only to subsystem component summaries. Any applications that require quick, efficient, and accurate weight, volume, resupply, or power summaries would be well suited to take advantage of SUBCOMDEF's capabilities.
Farmer, G.L.; Broxton, D.E.; Warren, R.G.; Pickthorn, W.
1991-01-01
Nd, Sr and O isotopic data were obtained from silicic ash-flow tuffs and lavas at the Tertiary age (16-9 Ma) Timber (Mountain/Oasis Valley volcanic center (TMOV) in southern Nevada, to assess models for the origin and evolution of the large-volume silicic magma bodies generated in this region. The large-volume (>900 km3), chemically-zoned, Topopah Spring (TS) and Tiva Canyon (TC) members of the Paintbrush Tuff, and the Rainier Mesa (RM) and Ammonia Tanks (AT) members of the younger Timber Mountain Tuff all have internal Nd and Sr isotopic zonations. In each tuff, high-silica rhyolites have lower initial e{open}Nd values (???1 e{open}Nd unit), higher87Sr/86Sr, and lower Nd and Sr contents, than cocrupted trachytes. The TS, TC, and RM members have similar e{open}Nd values for high-silica rhyolites (-11.7 to -11.2) and trachytes (-10.5 to -10.7), but the younger AT member has a higher e{open}Nd for both compositional types (-10.3 and -9.4). Oxygen isotope data confirm that the TC and AT members were derived from low e{open}Nd magmas. The internal Sr and Nd isotopic variations in each tuff are interpreted to be the result of the incorporation of 20-40% (by mass) wall-rock into magmas that were injected into the upper crust. The low e{open}Nd magmas most likely formed via the incorporation of low ??18O, hydrothermally-altered, wall-rock. Small-volume rhyolite lavas and ash-flow tuffs have similar isotopic characteristics to the large-volume ash-flow tuffs, but lavas erupted from extracaldera vents may have interacted with higher ??18O crustal rocks peripheral to the main magma chamber(s). Andesitic lavas from the 13-14 Ma Wahmonie/Salyer volcanic center southeast of the TMOV have low e{open}Nd (-13.2 to -13.8) and are considered on the basis of textural evidence to be mixtures of basaltic composition magmas and large proportions (70-80%) of anatectic crustal melts. A similar process may have occurred early in the magmatic history of the TMOV. The large-volume rhyolites may represent a mature stage of magmatism after repeated injection of basaltic magmas, crustal melting, and volcanism cleared sufficient space in the upper crust for large magma bodies to accumulate and differentiate. The TMOV rhyolites and 0-10 Ma old basalts that erupted in southern Nevada all have similar Nd and Sr isotopic compositions, which suggests that silicic and mafic magmatism at the TMOV were genetically related. The distinctive isotopic compositions of the AT member may reflect temporal changes in the isotopic compositions of basaltic magmas entering the upper crust, possibly as a result of increasing "basification" of a lower crustal magma source by repeated injection of mantle-derived mafic magmas. ?? 1991 Springer-Verlag.
Converting international ¼ inch tree volume to Doyle
Aaron Holley; John R. Brooks; Stuart A. Moss
2014-01-01
An equation for converting Mesavage and Girard's International ¼ inch tree volumes to the Doyle log rule is presented as a function of tree diameter. Volume error for trees having less than four logs exhibited volume prediction errors within a range of ±10 board feet. In addition, volume prediction error as a percent of actual Doyle tree volume...
Daily Planet Redesign: eZ Publish Web Content Management Implementation
NASA Technical Reports Server (NTRS)
Dutra, Jayne E.
2006-01-01
This viewgraph presentation reviews the process of the redesign of the Daily . Planet news letter as a content management implementation project. This is a site that is an internal news site that acts as a communication vehicle for a large volume of content. The Objectives for the site redesign was: (1) Clean visual design, (2) Facilitation of publication processes, (3) More efficient maintenance mode, (4) Automated publishing to internal portal, (5) Better navigation through improved site IA, (6) Archiving and retrieval functionality, (7) Back to basics on fundamental business goals. The CM is a process not a software package
Wetzel, Lindsay R; Patel, Priyesh R; Pesa, Nicholas L
2017-07-01
An elderly male presented for emergent repair of a ruptured abdominal aortic aneurysm. For anticipated volume resuscitation, vasopressor administration, and hemodynamic monitoring, a large-bore central venous catheter was placed in the left internal jugular vein under ultrasound guidance before surgical incision. Initially, there were no readily apparent signs of venous perforation. However, a massive left hemothorax developed because of perforation of the brachiocephalic vein and violation of the pleural space. This case report discusses both prevention and management of such a complication.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1980-01-01
This volume contains all abstracts (931) received by the conference organizers before June 20, 1980. The abstracts are grouped according to the following topics: nucleon-nucleon interactions, free and in nuclei; distribution of matter, charge, and magnetism; exotic nuclei and exotic probes; giant resonances and other high-lying excitations; applications of nuclear science; nuclei with large angular momentum and deformation; heavy-ion reactions and relaxation phenomena; new techniques and instruments; pion absorption and scattering by nuclei; and miscellaneous. Some of these one-page abstracts contain data. A complete author index is provided. (RWR)
ERIC Educational Resources Information Center
Jung, Jisun; Horta, Hugo
2015-01-01
Studies of higher education by scholars based in Asia have been growing in volume, following worldwide trends. To a large extent, this growth has been driven by East Asian countries, but little is known about the characteristics of the contribution of these countries. This study analyses their overall and specific contribution. The paper concludes…
Second-growth yield, stand, and volume tables for the western white pine type
Irvine T. Haig
1932-01-01
The western white pine type is the most important forest unit over large areas of rough uplands in northern Idaho and adjacent portions of eastern Washington and western Montana. It occupies throughout this region the cooler, moister sites between elevations of 2,000 and 5,500 feet, reaching its best development in northern Idaho between the international boundary and...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Almer, J. D.; Stock, S. R.; Northeastern Univ.
2010-08-26
High energy X-ray scattering (80.7keV photons) at station 1-ID of the Advanced Photon Source quantified internal strains as a function of applied stress in mature bovine tooth. These strains were mapped from dentin through the dentinoenamel junction (DEJ) into enamel as a function of applied compressive stress in two small parallelepiped specimens. One specimen was loaded perpendicular to the DEJ and the second parallel to the DEJ. Internal strains in enamel and dentin increased and, as expected from the relative values of the Young's modulus, the observed strains were much higher in dentin than in enamel. Large strain gradients weremore » observed across the DEJ, and the data suggest that the mantle dentin-DEJ-aprismatic enamel structure may shield the near-surface volume of the enamel from large strains. In the enamel, drops in internal strain for applied stresses above 40MPa also suggest that this structure had cracked.« less
Model-Data Assimilation of Internal Waves during ASIAEX-2001
NASA Technical Reports Server (NTRS)
Liu, Antony; Zhao, Yun-He; Tang, T. Y.; Ramp, Steven R.
2003-01-01
In recent Asian Seas International Acoustics Experiment (ASIAEX), extensive moorings have been deployed around the continental shelf break area in the northeast of South China Sea in May 2001. Simultaneous RADARSAT SAR images have been collected during the field test to integrate with the in-situ measurements from moorings, ship-board sensors, and CTD casts. Besides it provides synoptic information, satellite imagery is very useful for tracking the internal waves, and locating surface fronts and mesoscale features. During ASIAEX in May 2001, many large internal waves were observed at the test area and were the major oceanic features for acoustic volume interaction. Based on the internal wave distribution maps compiled from satellite data, the wave crest can be as long as 200 km with amplitude of 100 m. Environmental parameters have been calculated based on extensive CTD casts data near the ASIAEX area. Nonlinear internal wave models have been applied to integrate and assimilate both SAR and mooring data. Using SAR data in deep water as an initial condition, numerical simulations produce the wave evolution on the continental shelf and compared reasonably well with the mooring measurements at the downstream station. The shoaling, turning, and dissipation of large internal waves on the shelf break, elevation solitons, and wave-wave interaction have been studied and are very important issues for acoustic propagation. The internal wave effects on acoustic modal coupling has been implicated and discussed.
Challenges in Managing Trustworthy Large-scale Digital Science
NASA Astrophysics Data System (ADS)
Evans, B. J. K.
2017-12-01
The increased use of large-scale international digital science has opened a number of challenges for managing, handling, using and preserving scientific information. The large volumes of information are driven by three main categories - model outputs including coupled models and ensembles, data products that have been processing to a level of usability, and increasingly heuristically driven data analysis. These data products are increasingly the ones that are usable by the broad communities, and far in excess of the raw instruments data outputs. The data, software and workflows are then shared and replicated to allow broad use at an international scale, which places further demands of infrastructure to support how the information is managed reliably across distributed resources. Users necessarily rely on these underlying "black boxes" so that they are productive to produce new scientific outcomes. The software for these systems depend on computational infrastructure, software interconnected systems, and information capture systems. This ranges from the fundamentals of the reliability of the compute hardware, system software stacks and libraries, and the model software. Due to these complexities and capacity of the infrastructure, there is an increased emphasis of transparency of the approach and robustness of the methods over the full reproducibility. Furthermore, with large volume data management, it is increasingly difficult to store the historical versions of all model and derived data. Instead, the emphasis is on the ability to access the updated products and the reliability by which both previous outcomes are still relevant and can be updated for the new information. We will discuss these challenges and some of the approaches underway that are being used to address these issues.
NASA Technical Reports Server (NTRS)
Vos, Gordon A.; Fink, Patrick; Ngo, Phong H.; Morency, Richard; Simon, Cory; Williams, Robert E.; Perez, Lance C.
2017-01-01
Space Human Factors and Habitability (SHFH) Element within the Human Research Program (HRP) and the Behavioral Health and Performance (BHP) Element are conducting research regarding Net Habitable Volume (NHV), the internal volume within a spacecraft or habitat that is available to crew for required activities, as well as layout and accommodations within the volume. NASA needs methods to unobtrusively collect NHV data without impacting crew time. Data required includes metrics such as location and orientation of crew, volume used to complete tasks, internal translation paths, flow of work, and task completion times. In less constrained environments methods exist yet many are obtrusive and require significant post-processing. ?Examplesused in terrestrial settings include infrared (IR) retro-reflective marker based motion capture, GPS sensor tracking, inertial tracking, and multi-camera methods ?Due to constraints of space operations many such methods are infeasible. Inertial tracking systems typically rely upon a gravity vector to normalize sensor readings,and traditional IR systems are large and require extensive calibration. ?However, multiple technologies have not been applied to space operations for these purposes. Two of these include: 3D Radio Frequency Identification Real-Time Localization Systems (3D RFID-RTLS) ?Depth imaging systems which allow for 3D motion capture and volumetric scanning (such as those using IR-depth cameras like the Microsoft Kinect or Light Detection and Ranging / Light-Radar systems, referred to as LIDAR)
Longo, Benedetto; Farcomeni, Alessio; Ferri, Germano; Campanale, Antonella; Sorotos, Micheal; Santanelli, Fabio
2013-07-01
Breast volume assessment enhances preoperative planning of both aesthetic and reconstructive procedures, helping the surgeon in the decision-making process of shaping the breast. Numerous methods of breast size determination are currently reported but are limited by methodologic flaws and variable estimations. The authors aimed to develop a unifying predictive formula for volume assessment in small to large breasts based on anthropomorphic values. Ten anthropomorphic breast measurements and direct volumes of 108 mastectomy specimens from 88 women were collected prospectively. The authors performed a multivariate regression to build the optimal model for development of the predictive formula. The final model was then internally validated. A previously published formula was used as a reference. Mean (±SD) breast weight was 527.9 ± 227.6 g (range, 150 to 1250 g). After model selection, sternal notch-to-nipple, inframammary fold-to-nipple, and inframammary fold-to-fold projection distances emerged as the most important predictors. The resulting formula (the BREAST-V) showed an adjusted R of 0.73. The estimated expected absolute error on new breasts is 89.7 g (95 percent CI, 62.4 to 119.1 g) and the expected relative error is 18.4 percent (95 percent CI, 12.9 to 24.3 percent). Application of reference formula on the sample yielded worse predictions than those derived by the formula, showing an R of 0.55. The BREAST-V is a reliable tool for predicting small to large breast volumes accurately for use as a complementary device in surgeon evaluation. An app entitled BREAST-V for both iOS and Android devices is currently available for free download in the Apple App Store and Google Play Store. Diagnostic, II.
The Casimir effect in rugby-ball type flux compactifications
NASA Astrophysics Data System (ADS)
Minamitsuji, M.
2008-04-01
We discuss volume stabilization in a 6D braneworld model based on 6D supergravity theory. The internal space is compactified by magnetic flux and contains codimension two 3-branes (conical singularities) as its boundaries. In general the external 4D spacetime is warped and in the unwrapped limit the shape of the internal space looks like a 'rugby ball'. The size of the internal space is not fixed due to the scale invariance of the supergravity theory. We discuss the possibility of volume stabilization by the Casimir effect for a massless, minimally coupled bulk scalar field. The main obstacle in studying this case is that the brane (conical) part of the relevant heat kernel coefficient (a6) has not been formulated. Thus as a first step, we consider the 4D analog model with boundary codimension two 1-branes. The spacetime structure of the 4D model is very similar to that of the original 6D model, where now the relevant heat kernel coefficient is well known. We derive the one-loop effective potential induced by a scalar field in the bulk by employing zeta function regularization with heat kernel analysis. As a result, the volume is stabilized for most possible choices of the parameters. Especially, for a larger degree of warping, our results imply that a large hierarchy between the mass scales and a tiny amount of effective cosmological constant can be realized on the brane. In the non-warped limit the ratio tends to converge to the same value, independently of the bulk gauge coupling constant. Finally, we will analyze volume stabilization in the original model 6D by employing the same mode-sum technique.
Groundwater drainage from fissures as a source for lahars
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, P. J.; Valentine, G. A.; Stauffer, P. H.
One mechanism for generating lahars at volcanoes experiencing unrest is the disruption of internal aquifers. These disruptions can trigger releases of large quantities of groundwater. An example of such aquifer disruption occurred at Nevado del Huila Volcano, Colombia, during February and April 2007 when large fractures formed across the summit area of the volcano and lahars were emitted from them. Previous work interpreted that lahar volumes could not be accounted for by melted glacial snow or precipitation, and by elimination suggested that the primary water source was groundwater. Conceptual models have been developed for perched, confined aquifers that have beenmore » heated and pressurized by magma intrusions, followed by sudden pressure release and water emission during fracture formation. In this paper, we consider an alternative end member wherein water release from large fissures at volcanoes is driven by simple gravity drainage. We apply numerical modeling to quantify water discharge from the porous medium surrounding a fissure with a low-elevation free exit. If a long fracture with high vertical extent (on the order of hundreds of meters) intersects a highly connected saturated porous medium, large volumes (on order 10 3 m 3/m of crack length) of water may be released within tens of minutes. The drainage rates from the model may be adequate to account for the Nevado del Huila events if the medium surrounding the crack contains a large volume of water and has high horizontal permeability. Finally, this simple but poorly understood mechanism can present a hazard on its own or compound other processes releasing water from volcanoes.« less
Groundwater drainage from fissures as a source for lahars
NASA Astrophysics Data System (ADS)
Johnson, P. J.; Valentine, G. A.; Stauffer, P. H.; Lowry, C. S.; Sonder, I.; Pulgarín, B. A.; Santacoloma, C. C.; Agudelo, A.
2018-04-01
One mechanism for generating lahars at volcanoes experiencing unrest is the disruption of internal aquifers. These disruptions can trigger releases of large quantities of groundwater. An example of such aquifer disruption occurred at Nevado del Huila Volcano, Colombia, during February and April 2007 when large fractures formed across the summit area of the volcano and lahars were emitted from them. Previous work interpreted that lahar volumes could not be accounted for by melted glacial snow or precipitation, and by elimination suggested that the primary water source was groundwater. Conceptual models have been developed for perched, confined aquifers that have been heated and pressurized by magma intrusions, followed by sudden pressure release and water emission during fracture formation. We consider an alternative end member wherein water release from large fissures at volcanoes is driven by simple gravity drainage. We apply numerical modeling to quantify water discharge from the porous medium surrounding a fissure with a low-elevation free exit. If a long fracture with high vertical extent (on the order of hundreds of meters) intersects a highly connected saturated porous medium, large volumes (on order 103 m3/m of crack length) of water may be released within tens of minutes. The drainage rates from the model may be adequate to account for the Nevado del Huila events if the medium surrounding the crack contains a large volume of water and has high horizontal permeability. This simple but poorly understood mechanism can present a hazard on its own or compound other processes releasing water from volcanoes.
Groundwater drainage from fissures as a source for lahars
Johnson, P. J.; Valentine, G. A.; Stauffer, P. H.; ...
2018-03-22
One mechanism for generating lahars at volcanoes experiencing unrest is the disruption of internal aquifers. These disruptions can trigger releases of large quantities of groundwater. An example of such aquifer disruption occurred at Nevado del Huila Volcano, Colombia, during February and April 2007 when large fractures formed across the summit area of the volcano and lahars were emitted from them. Previous work interpreted that lahar volumes could not be accounted for by melted glacial snow or precipitation, and by elimination suggested that the primary water source was groundwater. Conceptual models have been developed for perched, confined aquifers that have beenmore » heated and pressurized by magma intrusions, followed by sudden pressure release and water emission during fracture formation. In this paper, we consider an alternative end member wherein water release from large fissures at volcanoes is driven by simple gravity drainage. We apply numerical modeling to quantify water discharge from the porous medium surrounding a fissure with a low-elevation free exit. If a long fracture with high vertical extent (on the order of hundreds of meters) intersects a highly connected saturated porous medium, large volumes (on order 10 3 m 3/m of crack length) of water may be released within tens of minutes. The drainage rates from the model may be adequate to account for the Nevado del Huila events if the medium surrounding the crack contains a large volume of water and has high horizontal permeability. Finally, this simple but poorly understood mechanism can present a hazard on its own or compound other processes releasing water from volcanoes.« less
Significance of major international seaports in the distribution of murine typhus in Taiwan.
Kuo, Chi-Chien; Wardrop, Nicola; Chang, Chung-Te; Wang, Hsi-Chieh; Atkinson, Peter M
2017-03-01
International seaports are hotspots for disease invasion and pathogens can persist in seaports even after ports are abandoned. Transmitted by fleas infected by Rickettsia typhi, murine typhus, a largely neglected and easily misdiagnosed disease, is known to occur primarily in large seaports. However, the significance of seaports in the occurrence of murine typhus has never been validated quantitatively. We studied the spatial distribution of murine typhus, a notifiable disease, in Taiwan. We investigated whether risk of infection was correlated with distance to international seaports and a collection of environmental and socioeconomic factors, using a Bayesian negative binomial conditionally autoregressive model, followed with geographically weighted regression. Seaports that are currently in use and those that operated in the 19th century for trade with China, but were later abandoned due to siltation were analyzed. A total of 476 human cases of murine typhus were reported during 2000-2014 in the main island of Taiwan, with spatial clustering in districts in southwest and central-west Taiwan. A higher incidence rate (case/population) was associated with a smaller distance to currently in-use international seaports and lower rainfall and temperature, but was uncorrelated with distance to abandoned ports. Geographically weighted regression revealed a geographic heterogeneity in the importance of distance to in-use seaports near the four international seaports of Taiwan. Our study suggests that murine typhus is associated with international seaports, especially for those with large trading volume. Thus, one of the costs of global trade in Taiwan might be elevated risks of murine typhus. Globalization has accelerated the spread of infectious diseases, but the burden of disease varies geographically, with regions surrounding major international seaports warranting particular surveillance.
Significance of major international seaports in the distribution of murine typhus in Taiwan
Wardrop, Nicola; Chang, Chung-Te; Wang, Hsi-Chieh; Atkinson, Peter M.
2017-01-01
Background International seaports are hotspots for disease invasion and pathogens can persist in seaports even after ports are abandoned. Transmitted by fleas infected by Rickettsia typhi, murine typhus, a largely neglected and easily misdiagnosed disease, is known to occur primarily in large seaports. However, the significance of seaports in the occurrence of murine typhus has never been validated quantitatively. Methodology/Principal findings We studied the spatial distribution of murine typhus, a notifiable disease, in Taiwan. We investigated whether risk of infection was correlated with distance to international seaports and a collection of environmental and socioeconomic factors, using a Bayesian negative binomial conditionally autoregressive model, followed with geographically weighted regression. Seaports that are currently in use and those that operated in the 19th century for trade with China, but were later abandoned due to siltation were analyzed. A total of 476 human cases of murine typhus were reported during 2000–2014 in the main island of Taiwan, with spatial clustering in districts in southwest and central-west Taiwan. A higher incidence rate (case/population) was associated with a smaller distance to currently in-use international seaports and lower rainfall and temperature, but was uncorrelated with distance to abandoned ports. Geographically weighted regression revealed a geographic heterogeneity in the importance of distance to in-use seaports near the four international seaports of Taiwan. Conclusions/Significance Our study suggests that murine typhus is associated with international seaports, especially for those with large trading volume. Thus, one of the costs of global trade in Taiwan might be elevated risks of murine typhus. Globalization has accelerated the spread of infectious diseases, but the burden of disease varies geographically, with regions surrounding major international seaports warranting particular surveillance. PMID:28264003
NASA Astrophysics Data System (ADS)
Martin, Spencer; Brophy, Mark; Palma, David; Louie, Alexander V.; Yu, Edward; Yaremko, Brian; Ahmad, Belal; Barron, John L.; Beauchemin, Steven S.; Rodrigues, George; Gaede, Stewart
2015-02-01
This work aims to propose and validate a framework for tumour volume auto-segmentation based on ground-truth estimates derived from multi-physician input contours to expedite 4D-CT based lung tumour volume delineation. 4D-CT datasets of ten non-small cell lung cancer (NSCLC) patients were manually segmented by 6 physicians. Multi-expert ground truth (GT) estimates were constructed using the STAPLE algorithm for the gross tumour volume (GTV) on all respiratory phases. Next, using a deformable model-based method, multi-expert GT on each individual phase of the 4D-CT dataset was propagated to all other phases providing auto-segmented GTVs and motion encompassing internal gross target volumes (IGTVs) based on GT estimates (STAPLE) from each respiratory phase of the 4D-CT dataset. Accuracy assessment of auto-segmentation employed graph cuts for 3D-shape reconstruction and point-set registration-based analysis yielding volumetric and distance-based measures. STAPLE-based auto-segmented GTV accuracy ranged from (81.51 ± 1.92) to (97.27 ± 0.28)% volumetric overlap of the estimated ground truth. IGTV auto-segmentation showed significantly improved accuracies with reduced variance for all patients ranging from 90.87 to 98.57% volumetric overlap of the ground truth volume. Additional metrics supported these observations with statistical significance. Accuracy of auto-segmentation was shown to be largely independent of selection of the initial propagation phase. IGTV construction based on auto-segmented GTVs within the 4D-CT dataset provided accurate and reliable target volumes compared to manual segmentation-based GT estimates. While inter-/intra-observer effects were largely mitigated, the proposed segmentation workflow is more complex than that of current clinical practice and requires further development.
Martin, Spencer; Brophy, Mark; Palma, David; Louie, Alexander V; Yu, Edward; Yaremko, Brian; Ahmad, Belal; Barron, John L; Beauchemin, Steven S; Rodrigues, George; Gaede, Stewart
2015-02-21
This work aims to propose and validate a framework for tumour volume auto-segmentation based on ground-truth estimates derived from multi-physician input contours to expedite 4D-CT based lung tumour volume delineation. 4D-CT datasets of ten non-small cell lung cancer (NSCLC) patients were manually segmented by 6 physicians. Multi-expert ground truth (GT) estimates were constructed using the STAPLE algorithm for the gross tumour volume (GTV) on all respiratory phases. Next, using a deformable model-based method, multi-expert GT on each individual phase of the 4D-CT dataset was propagated to all other phases providing auto-segmented GTVs and motion encompassing internal gross target volumes (IGTVs) based on GT estimates (STAPLE) from each respiratory phase of the 4D-CT dataset. Accuracy assessment of auto-segmentation employed graph cuts for 3D-shape reconstruction and point-set registration-based analysis yielding volumetric and distance-based measures. STAPLE-based auto-segmented GTV accuracy ranged from (81.51 ± 1.92) to (97.27 ± 0.28)% volumetric overlap of the estimated ground truth. IGTV auto-segmentation showed significantly improved accuracies with reduced variance for all patients ranging from 90.87 to 98.57% volumetric overlap of the ground truth volume. Additional metrics supported these observations with statistical significance. Accuracy of auto-segmentation was shown to be largely independent of selection of the initial propagation phase. IGTV construction based on auto-segmented GTVs within the 4D-CT dataset provided accurate and reliable target volumes compared to manual segmentation-based GT estimates. While inter-/intra-observer effects were largely mitigated, the proposed segmentation workflow is more complex than that of current clinical practice and requires further development.
How predictable is the timing of a summer ice-free Arctic?
NASA Astrophysics Data System (ADS)
Jahn, Alexandra; Kay, Jennifer E.; Holland, Marika M.; Hall, David M.
2016-09-01
Climate model simulations give a large range of over 100 years for predictions of when the Arctic could first become ice free in the summer, and many studies have attempted to narrow this uncertainty range. However, given the chaotic nature of the climate system, what amount of spread in the prediction of an ice-free summer Arctic is inevitable? Based on results from large ensemble simulations with the Community Earth System Model, we show that internal variability alone leads to a prediction uncertainty of about two decades, while scenario uncertainty between the strong (Representative Concentration Pathway (RCP) 8.5) and medium (RCP4.5) forcing scenarios adds at least another 5 years. Common metrics of the past and present mean sea ice state (such as ice extent, volume, and thickness) as well as global mean temperatures do not allow a reduction of the prediction uncertainty from internal variability.
Merging Surface Reconstructions of Terrestrial and Airborne LIDAR Range Data
2009-05-19
Mangan and R. Whitaker. Partitioning 3D surface meshes using watershed segmentation . IEEE Trans. on Visualization and Computer Graphics, 5(4), pp...Jain, and A. Zakhor. Data Processing Algorithms for Generating Textured 3D Building Facade Meshes from Laser Scans and Camera Images. International...acquired set of overlapping range images into a single mesh [2,9,10]. However, due to the volume of data involved in large scale urban modeling, data
NASA Technical Reports Server (NTRS)
Petro, Elaine; Hughes, David
2011-01-01
Analysis has been performed for MAVEN mission. Due to the elliptical orbit, large pressure variations in orbit will be experienced, there is a need to understand how internal pressures change and the flux of gas from vents could potentially bias instrument measurements. Goal of this analysis is to predict the effect that atmospheric gases trapped and vented from spacecraft volumes could have on instrument measurements.
NASA Technical Reports Server (NTRS)
Labitzke, K. (Editor); Barnett, J. J. (Editor); Edwards, B. (Editor)
1985-01-01
A draft of a new reference atmosphere for the region between 20 and 80 km which depends largely on recent satellite experiments covering the globe from 80 deg S to 80 deg N is given. A separate international tropical reference atmosphere is given, as well as reference ozone models for the middle atmosphere.
Biological Effects of Nonionizing Electromagnetic Radiation. Volume V, Number 1.
1980-09-01
temperature are Mande, France); Doury, P.: Conrad. J.: Metges. P. J.. close to the limits for protein denaturation: this may Pattin. S. Med Aeronaut Spat 18...large cylinder or mat.netrode that. TECHNIOUE USED TO TREAT according to Dr. Storm, provides "deep internal CANCER PATIENTS heating to any depth with no...investiga- cells. Two aspects of microwave hyperthermia-- tion, hyperthermla is never used as a first line localized heating and accurate temperature
Kuwatsuka, Yachiyo
2016-01-01
Observational studies from national and international registries with large volumes of patients are commonly performed to identify superior strategies for hematopoietic stem cell transplantation. Major international and national stem cell transplant registries collect outcome data using electronic data capture systems, and a systematic study support process has been developed. Statistical support for studies is available from some major international registries, and international and national registries also mutually collaborate to promote stem cell transplant outcome studies and transplant-related activities. Transplant registries additionally take measures to improve data quality to further improve the quality of outcome studies by utilizing data capture systems and manual data management. Data auditing can potentially even further improve data quality; however, human and budgetary resources can be limiting factors in system construction and audits of the Japanese transplant registry are not currently performed.
Data and Model Integration Promoting Interdisciplinarity
NASA Astrophysics Data System (ADS)
Koike, T.
2014-12-01
It is very difficult to reflect accumulated subsystem knowledge into holistic knowledge. Knowledge about a whole system can rarely be introduced into a targeted subsystem. In many cases, knowledge in one discipline is inapplicable to other disciplines. We are far from resolving cross-disciplinary issues. It is critically important to establish interdisciplinarity so that scientific knowledge can transcend disciplines. We need to share information and develop knowledge interlinkages by building models and exchanging tools. We need to tackle a large increase in the volume and diversity of data from observing the Earth. The volume of data stored has exponentially increased. Previously, almost all of the large-volume data came from satellites, but model outputs occupy the largest volume in general. To address the large diversity of data, we should develop an ontology system for technical and geographical terms in coupling with a metadata design according to international standards. In collaboration between Earth environment scientists and IT group, we should accelerate data archiving by including data loading, quality checking and metadata registration, and enrich data-searching capability. DIAS also enables us to perform integrated research and realize interdisciplinarity. For example, climate change should be addressed in collaboration between the climate models, integrated assessment models including energy, economy, agriculture, health, and the models of adaptation, vulnerability, and human settlement and infrastructure. These models identify water as central to these systems. If a water expert can develop an interrelated system including each component, the integrated crisis can be addressed by collaboration with various disciplines. To realize this purpose, we are developing a water-related data- and model-integration system called a water cycle integrator (WCI).
Bronnenkant, L
1994-01-01
A representative of Finishing Enterprises, the world's largest manufacturer of intrauterine contraceptive devices (IUDs), discusses how to alter the balance of incentives-disincentives to expedite the development of HIV vaccines for international evaluation. Three main disincentives exist for private manufacturers in the United States to develop a new HIV vaccine to be used in developing countries, outside the profitable North American and western European markets: 1) low profit margin because of limited money, time, and resources. Medium and large-sized corporations are more concerned with a high return on their investment owing to stockholder pressure than with the human benefit of that investment. 2) Lengthy regulatory approval process. The current regulatory process in the US is tedious, time-consuming, and costly. 3) Liability risk. The United States is the most litigious society in the world. Suits filed against US corporations involved in drug manufacture incur legal defence costs, which make an already low profit margin HIV vaccine even lower. Finishing Enterprises' IUD program aimed at providing the safest and most effective IUD at an affordable price in a socially responsible way. The Population Council developed the Copper T and retained the patent rights. They and other international health authorities, such as the World Health Organization, conducted or monitored international clinical trials to determine safety and efficacy. Private foundations and public donor agencies funded these activities. When donor agencies committed to volume purchases for their commodity programs, Finishing Enterprises could commit to volume pricing. Whenever high-margin private sector sales occur, Population Council receives a royalty payment. Thus, the disincentives were overcome: 1) Low profit margin was less an issue for a small, private company created specifically to manufacture IUDs and guaranteed volume orders. 2) Lengthy regulatory approval processes were avoided by various international clinical trials, generating international interest in the product. 3) Liability risk was minimized by the variety of safety tests the product underwent.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schnetzer, G.H.; Fisher, R.J.; Dinallo, M.A.
1994-08-01
The electrical effects of lightning penetration of the outer case of a weapon on internal structures, such as a firing set housing, and on samples of a flat, flexline detonator cable have been investigated experimentally. Maximum open-circuit voltages measured on either simulated structures (126 V) or the cable (46 V) located directly behind the point of penetration were well below any level that is foreseen to create a threat to nuclear safety. On the other hand, it was found that once full burnthrough of the barrier occurred, significant fractions of the incident continuing currents coupled to both the simulated internalmore » structure (up to 300 A) or to the cable sample (69 A) when each was electrically connected internally to case ground. No occurrence was observed of the injection of large amplitude currents from return strokes occurring after barrier penetration. Under circumstances in which small volumes of trapped gases exist behind penetration sites, rapid heating of the gas by return strokes occurring after burnthrough has been shown to produced large mechanical impulses to the adjacent surfaces.« less
McQueen, K A Kelly; Hyder, Joseph A; Taira, Breena R; Semer, Nadine; Burkle, Frederick M; Casey, Kathleen M
2010-03-01
Emerging data demonstrate that a large fraction of the global burden of disease is amenable to surgical intervention. There is a paucity of data related to delivery of surgical care in low- and middle-income countries, and no aggregate data describe the efforts of international organizations to provide surgical care in these settings. This study was designed to describe the roles and practices of international organizations delivering surgical care in developing nations with regard to surgical types and volume, outcomes tracking, and degree of integration with local health systems. Between October 2008 and December 2008, an Internet-based confidential questionnaire was distributed to 99 international organizations providing humanitarian surgical care to determine their size, scope, involvement in surgical data collection, and integration into local systems. Forty-six international organizations responded (response rate 46%). Findings reveal that a majority of organizations that provide surgery track numbers of cases performed and immediate outcomes, such as mortality. In general, these groups have mechanisms in place to track volume and outcomes, provide for postintervention follow-up, are committed to providing education, and work in conjunction with local health organizations and providers. Whereas most organizations surveyed provided fewer than 500 surgical procedures annually, more than half had the capacity to provide emergency services. In addition, a great diversity of specialized surgical care was provided, including obstetrics, orthopedic, plastic, and ophthalmologic surgery. International organizations providing surgical services are diverse in size and breadth of surgical services provided yet, with consistency, provide rudimentary analysis, postoperative follow-up care, and both education and integration of health services at the local level. The role of international organizations in the delivery of surgery is an important index, worthy of further evaluation.
Nano-confinement inside molecular metal oxide clusters: Dynamics and modified encapsulation behavior
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Zhe; Daemen, Luke L.; Cheng, Yongqiang
Encapsulation behavior, as well as the presence of internal catalytically-active sites, has been spurring the applications of a 3 nm hollow spherical metal oxide cluster {Mo 132} as an encapsulation host and a nano-reactor. Due to its well-defined and tunable cluster structures, and nano-scaled internal void space comparable to the volumes of small molecules, this cluster provides a good model to study the dynamics of materials under ultra-confinement. Neutron scattering studies suggest that bulky internal ligands inside the cluster show slower and limited dynamics compared to their counterparts in the bulk state, revealing the rigid nature of the skeleton ofmore » the internal ligands. Furthermore, NMR studies indicate that the rigid internal ligands that partially cover the interfacial pore on the molybdenum oxide shells are able to block some large guest molecules from going inside the capsule cluster, which provides a convincing protocol for size-selective encapsulation and separation.« less
Nano-confinement inside molecular metal oxide clusters: Dynamics and modified encapsulation behavior
Wang, Zhe; Daemen, Luke L.; Cheng, Yongqiang; ...
2016-08-19
Encapsulation behavior, as well as the presence of internal catalytically-active sites, has been spurring the applications of a 3 nm hollow spherical metal oxide cluster {Mo 132} as an encapsulation host and a nano-reactor. Due to its well-defined and tunable cluster structures, and nano-scaled internal void space comparable to the volumes of small molecules, this cluster provides a good model to study the dynamics of materials under ultra-confinement. Neutron scattering studies suggest that bulky internal ligands inside the cluster show slower and limited dynamics compared to their counterparts in the bulk state, revealing the rigid nature of the skeleton ofmore » the internal ligands. Furthermore, NMR studies indicate that the rigid internal ligands that partially cover the interfacial pore on the molybdenum oxide shells are able to block some large guest molecules from going inside the capsule cluster, which provides a convincing protocol for size-selective encapsulation and separation.« less
Comparison between Hydrogen, Methane and Ethylene Fuels in a 3-D Scramjet at Mach 8
2016-06-24
characteristics in air. The disadvantage of hydrogen is its low density, which is a particular problem for small vehicles with significant internal...characteristics in air. The disadvantage of hydrogen is its low density, which is a particular problem for small vehicles with significant internal volume...The low energy per unit volume of gaseous hydrogen, however, is a significant problem for small vehicles with internal volume constraints, in addition
Scanning of vehicles for nuclear materials
NASA Astrophysics Data System (ADS)
Katz, J. I.
2014-05-01
Might a nuclear-armed terrorist group or state use ordinary commerce to deliver a nuclear weapon by smuggling it in a cargo container or vehicle? This delivery method would be the only one available to a sub-state actor, and it might enable a state to make an unattributed attack. Detection of a weapon or fissile material smuggled in this manner is difficult because of the large volume and mass available for shielding. Here I review methods for screening cargo containers to detect the possible presence of nuclear threats. Because of the large volume of innocent international commerce, and the cost and disruption of secondary screening by opening and inspection, it is essential that the method be rapid and have a low false-positive rate. Shielding can prevent the detection of neutrons emitted spontaneously or by induced fission. The two promising methods are muon tomography and high energy X-radiography. If they do not detect a shielded threat object they can detect the shield itself.
Scanning of vehicles for nuclear materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Katz, J. I.
2014-05-09
Might a nuclear-armed terrorist group or state use ordinary commerce to deliver a nuclear weapon by smuggling it in a cargo container or vehicle? This delivery method would be the only one available to a sub-state actor, and it might enable a state to make an unattributed attack. Detection of a weapon or fissile material smuggled in this manner is difficult because of the large volume and mass available for shielding. Here I review methods for screening cargo containers to detect the possible presence of nuclear threats. Because of the large volume of innocent international commerce, and the cost andmore » disruption of secondary screening by opening and inspection, it is essential that the method be rapid and have a low false-positive rate. Shielding can prevent the detection of neutrons emitted spontaneously or by induced fission. The two promising methods are muon tomography and high energy X-radiography. If they do not detect a shielded threat object they can detect the shield itself.« less
NASA Astrophysics Data System (ADS)
Mazumdar, I.; Gothe, D. A.; Anil Kumar, G.; Yadav, N.; Chavan, P. B.; Patel, S. M.
2013-03-01
This paper presents the results of our measurements and detailed simulations using GEANT4 to investigate the performance of a large volume (946 cm3) cylindrical (3.5 in.diameter×6 in.length) LaBr3:Ce detector. The properties of the detector have been studied using γ-rays from radioactive sources and in-beam reaction, from few hundred keV to 22.5 MeV. The salient features, which have been studied in-depth, are the uniformity and internal activity of the crystal, the energy and timing resolutions, linearity of the response up to 22.5 MeV, and efficiencies. A highly linear response has been observed by extracting the energy signal from a lower dynode and operating the PMT at a low voltage. The detector is to be primarily used for measuring high energy γ-rays spectra from Giant Dipole Resonance (GDR) decay studies.
Zhu, Wenzhen; Yang, Jian; Iqbal, Jabed; Peck, Yvonne; Fan, Changjiang; Wang, Dong-An
2017-07-01
Seroma formation is a common postsurgical complication of breast cancer surgery. It delays wound healing and may lead to other more serious complications. Conventional methods of reducing seroma formation through suturing or placement of surgical drainage produce inconsistent clinical outcomes. Tissue adhesives are viable alternatives but most of them are unsuitable for internal use and for large-area applications because of weak tissue adhesion strength or biocompatibility issues. The aim of this study was to evaluate the efficacy and biocompatibility of a mussel-inspired double-crosslinked tissue adhesive (DCTA) in reducing seroma formation after mastectomy. Thirty-six female Sprague-Dawley rats were randomly assigned to either the saline control group (n = 12), the TISSEEL sealant (Baxter) group (n = 12), or the DCTA group (n = 12). After performing a mastectomy and applying the corresponding treatment, the efficacy of DCTA was evaluated by measurement of seroma volume while its biocompatibility was assessed via micronuclei test and histopathologic examination. During the 1-wk postsurgical period, the average total seroma volume of DCTA was significantly lower than the saline control group. Importantly, the mean seroma volume in DCTA showed a decreasing trend, whereas those in TISSEEL and saline control groups showed otherwise. The application of DCTA showed no genotoxic effect on the host and no severe inflammation. This study demonstrates that the good tissue adhesion strength and stability of DCTA were successful in reducing seroma formation over a period of 1 wk. Furthermore, the results also showed that it is biocompatible, which makes it suitable for large-area, internal use. Copyright © 2017 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Popov, Nikolay, Ed.; Wolhuter, Charl, Ed.; Kalin, Jana, Ed.; Hilton, Gillian, Ed.; Ogunleye, James, Ed.; Niemczyk, Ewelina, Ed.
2016-01-01
Papers from the proceedings of the 14th Annual Conference of the Bulgarian Comparative Education Society was submitted in two volumes. Volume 1 contains papers submitted at the conference held in Sofia, Bulgaria, June 14-17, 2016. Volume 2 contains papers submitted at the 4th International Partner Conference of the International Research Centre…
ERIC Educational Resources Information Center
Chigisheva, Oksana, Ed.; Popov, Nikolay, Ed.
2016-01-01
Papers from the proceedings of the 14th Annual Conference of the Bulgarian Comparative Education Society were submitted in two volumes. Volume 1 contains papers submitted at the conference held in Sofia, Bulgaria, June 14-17, 2016. Volume 2 contains papers submitted at the 4th International Partner Conference of the International Research Centre…
Strategies for Analyzing Sub-Micrometer Features with the FE-EPMA
NASA Astrophysics Data System (ADS)
McSwiggen, P.; Armstrong, J. T.; Nielsen, C.
2013-12-01
Changes in column design and electronics, as well as new types of spectrometers and analyzing crystals, have significantly advanced electron microprobes, in terms of stability, reproducibility and detection limits. A major advance in spatial resolution has occurred through the use of the field emission electron gun. The spatial resolution of an analysis is controlled by the diameter of the electron beam and the amount of scatter that takes place within the sample. The beam diameter is controlled by the column and type of electron gun being used. The accelerating voltage and the average atomic number/density of the sample control the amount of electron scatter within the sample. However a large electron interaction volume does not necessarily mean a large analytical volume. The beam electrons may spread out within a large volume, but if the electrons lack sufficient energy to produce the X-ray of interest, the analytical volume could be significantly smaller. Therefore there are two competing strategies for creating the smallest analytical volumes. The first strategy is to reduce the accelerating voltage to produce the smallest electron interaction volume. This low kV analytical approach is ultimately limited by the size of the electron beam itself. With a field emission gun, normally the smallest analytical area is achieved at around 5-7 kV. At lower accelerating voltages, the increase in the beam diameter begins to overshadow the reduction in internal scattering. For tungsten filament guns, the smallest analytical volume is reached at higher accelerating voltages. The second strategy is to minimize the overvoltage during the analysis. If the accelerating voltage is only 1-3 kV greater than the critical ionization energy for the X-ray line of interest, then even if the overall electron interaction volume is large, those electrons quickly loose sufficient energy to produce the desired X-rays. The portion of the interaction volume in which the desired X-rays will be produce will be very small and very near the surface. Both strategies have advantages and disadvantages depending on the ultimate goal of the analysis and the elements involved. This work will examine a number of considerations when attempting to decide which approach is best for a given analytical situation. These include: (1) the size of the analytical volumes, (2) minimum detection limits, (3) quality of the matrix corrections, (4) secondary fluorescence, (5) effects of surface contamination, oxide layers, and carbon coatings. This work is based on results largely from the Fe-Ni binary. A simple conclusion cannot be draw as to which strategy is better overall. The determination is highly system dependent. For many mineral systems, both strategies used in combination will produce the best results. Using multiple accelerating voltages to preform a single analysis allows the analyst to optimize their analytical conditions for each element individually.
NASA Technical Reports Server (NTRS)
Vos, Gordon A.; Fink, Patrick; Ngo, Phong H.; Morency, Richard; Simon, Cory; Williams, Robert E.; Perez, Lance C.
2015-01-01
Space Human Factors and Habitability (SHFH) Element within the Human Research Program (HRP), in collaboration with the Behavioral Health and Performance (BHP) Element, is conducting research regarding Net Habitable Volume (NHV), the internal volume within a spacecraft or habitat that is available to crew for required activities, as well as layout and accommodations within that volume. NASA is looking for innovative methods to unobtrusively collect NHV data without impacting crew time. Data required includes metrics such as location and orientation of crew, volume used to complete tasks, internal translation paths, flow of work, and task completion times. In less constrained environments methods for collecting such data exist yet many are obtrusive and require significant post-processing. Example technologies used in terrestrial settings include infrared (IR) retro-reflective marker based motion capture, GPS sensor tracking, inertial tracking, and multiple camera filmography. However due to constraints of space operations many such methods are infeasible, such as inertial tracking systems which typically rely upon a gravity vector to normalize sensor readings, and traditional IR systems which are large and require extensive calibration. However multiple technologies have not yet been applied to space operations for these explicit purposes. Two of these include 3-Dimensional Radio Frequency Identification Real-Time Localization Systems (3D RFID-RTLS) and depth imaging systems which allow for 3D motion capture and volumetric scanning (such as those using IR-depth cameras like the Microsoft Kinect or Light Detection and Ranging / Light-Radar systems, referred to as LIDAR).
Individualized Internal and External Training Load Relationships in Elite Wheelchair Rugby Players.
Paulson, Thomas A W; Mason, Barry; Rhodes, James; Goosey-Tolfrey, Victoria L
2015-01-01
The quantification and longitudinal monitoring of athlete training load (TL) provides a scientific explanation for changes in performance and helps manage injury/illness risk. Therefore, accurate and reliable monitoring tools are essential for the optimization of athletic performance. The aim of the present study was to establish the relationship between measures of internal [heart rate (HR) and session RPE (sRPE)] and external TL specific to wheelchair rugby (WR). Fourteen international WR athletes (age = 29 ± 7 years; body mass = 58.9 ± 10.9 kg) were monitored during 18 training sessions over a 3 month period during the competitive phase of the season. Activity profiles were collected during each training session using a radio-frequency based indoor tracking system (ITS). External TL was quantified by total distance (m) covered as well as time spent and distance covered in a range of classification-specific arbitrary speed zones. Banister's TRIMP, Edwards's summated HR zone (SHRZ), and Lucia's TRIMP methods were used to quantify physiological internal TL. sRPE was calculated as the product of session duration multiplied by perceived exertion using the Borg CR10 scale. Relationships between external and internal TL were examined using correlation coefficients and the 90% confidence intervals (90% CI). sRPE (r = 0.59) and all HR-based (r > 0.80) methods showed large and very large relationships with the total distance covered during training sessions, respectively. Large and very large correlations (r = 0.56 - 0.82) were also observed between all measures of internal TL and times spent and distances covered in low and moderate intensity speed zones. HR-based methods showed very large relationships with time (r = 0.71-0.75) and distance (r = 0.70-0.73) in the very high speed zone and a large relationship with the number of high intensity activities (HIA) performed (r = 0.56-0.62). Weaker relationships (r = 0.32-0.35) were observed between sRPE and all measures of high intensity activity. A large variation of individual correlation co-efficient was observed between sRPE and all external TL measures. The current findings suggest that sRPE and HR-based internal TL measures provide a valid tool for quantifying volume of external TL during WR training but may underestimate HIA. It is recommended that both internal and external TL measures are employed for the monitoring of overall TL during court-based training in elite WR athletes.
Individualized Internal and External Training Load Relationships in Elite Wheelchair Rugby Players
Paulson, Thomas A. W.; Mason, Barry; Rhodes, James; Goosey-Tolfrey, Victoria L.
2015-01-01
Aim: The quantification and longitudinal monitoring of athlete training load (TL) provides a scientific explanation for changes in performance and helps manage injury/illness risk. Therefore, accurate and reliable monitoring tools are essential for the optimization of athletic performance. The aim of the present study was to establish the relationship between measures of internal [heart rate (HR) and session RPE (sRPE)] and external TL specific to wheelchair rugby (WR). Methods: Fourteen international WR athletes (age = 29 ± 7 years; body mass = 58.9 ± 10.9 kg) were monitored during 18 training sessions over a 3 month period during the competitive phase of the season. Activity profiles were collected during each training session using a radio-frequency based indoor tracking system (ITS). External TL was quantified by total distance (m) covered as well as time spent and distance covered in a range of classification-specific arbitrary speed zones. Banister's TRIMP, Edwards's summated HR zone (SHRZ), and Lucia's TRIMP methods were used to quantify physiological internal TL. sRPE was calculated as the product of session duration multiplied by perceived exertion using the Borg CR10 scale. Relationships between external and internal TL were examined using correlation coefficients and the 90% confidence intervals (90% CI). Results: sRPE (r = 0.59) and all HR-based (r > 0.80) methods showed large and very large relationships with the total distance covered during training sessions, respectively. Large and very large correlations (r = 0.56 − 0.82) were also observed between all measures of internal TL and times spent and distances covered in low and moderate intensity speed zones. HR-based methods showed very large relationships with time (r = 0.71−0.75) and distance (r = 0.70−0.73) in the very high speed zone and a large relationship with the number of high intensity activities (HIA) performed (r = 0.56−0.62). Weaker relationships (r = 0.32−0.35) were observed between sRPE and all measures of high intensity activity. A large variation of individual correlation co-efficient was observed between sRPE and all external TL measures. Conclusion: The current findings suggest that sRPE and HR-based internal TL measures provide a valid tool for quantifying volume of external TL during WR training but may underestimate HIA. It is recommended that both internal and external TL measures are employed for the monitoring of overall TL during court-based training in elite WR athletes. PMID:26733881
DOE Office of Scientific and Technical Information (OSTI.GOV)
Besemer, A; Marsh, I; Bednarz, B
Purpose: The calculation of 3D internal dose calculations in targeted radionuclide therapy requires the acquisition and temporal coregistration of a serial PET/CT or SPECT/CT images. This work investigates the dosimetric impact of different temporal coregistration methods commonly used for 3D internal dosimetry. Methods: PET/CT images of four mice were acquired at 1, 24, 48, 72, 96, 144 hrs post-injection of {sup 124}I-CLR1404. The therapeutic {sup 131}I-CLR1404 absorbed dose rate (ADR) was calculated at each time point using a Geant4-based MC dosimetry platform using three temporal image coregistration Methods: (1) no coregistration (NC), whole body sequential CT-CT affine coregistration (WBAC), andmore » individual sequential ROI-ROI affine coregistration (IRAC). For NC, only the ROI mean ADR was integrated to obtain ROI mean doses. For WBAC, the CT at each time point was coregistered to a single reference CT. The CT transformations were applied to the corresponding ADR images and the dose was calculated on a voxel-basis within the whole CT volume. For IRAC, each individual ROI was isolated and sequentially coregistered to a single reference ROI. The ROI transformations were applied to the corresponding ADR images and the dose was calculated on a voxel-basis within the ROI volumes. Results: The percent differences in the ROI mean doses were as large as 109%, 88%, and 32%, comparing the WBAC vs. IRAC, NC vs. IRAC, and NC vs. WBAC methods, respectively. The CoV in the mean dose between the all three methods ranged from 2–36%. The pronounced curvature of the spinal cord was not adequately coregistered using WBAC which resulted in large difference between the WBAC and IRAC. Conclusion: The method used for temporal image coregistration can result in large differences in 3D internal dosimetry calculations. Care must be taken to choose the most appropriate method depending on the imaging conditions, clinical site, and specific application. This work is partially funded by NIH Grant R21 CA198392-01.« less
NASA Technical Reports Server (NTRS)
Hayes, J. D.
1972-01-01
The feasibility of monitoring volatile contaminants in a large space simulation chamber using techniques of internal reflection spectroscopy was demonstrated analytically and experimentally. The infrared spectral region was selected as the operational spectral range in order to provide unique identification of the contaminants along with sufficient sensitivity to detect trace contaminant concentrations. It was determined theoretically that a monolayer of the contaminants could be detected and identified using optimized experimental procedures. This ability was verified experimentally. Procedures were developed to correct the attenuated total reflectance spectra for thick sample distortion. However, by using two different element designs the need for such correction can be avoided.
1992-12-01
composite system was made of carbon black-filled proprietary rubber compound matrix and 1260/2 39- 6 nylon cord reinforcement laid at an angle of +/-38...1.5 urn. 2) These are ternary compounds without the additional complication of added phosphorous as in the common compound InGaAsP. 3) Recent...theoretical coirputations indicate that these compounds may have large optical nonlinearities. For thin layers the lattice mismatch induces internal strain
In-house recruiters: on the inside looking out.
Vavala, D
1995-09-01
Few smaller hospitals or managed care companies have in-house physician recruiting departments. Their low hiring volume simply doesn't support such an operation. But most health systems and large managed care organizations say they literally couldn't afford to be without an internal system for the recruitment of physician executives and other health care professionals. They also claim they can find a better candidate faster than their counterparts on the outside. A number of them explain why.
2014-10-02
hadoop / Bradicich, T. & Orci, S. (2012). Moore’s Law of Big Data National Instruments Instrumentation News. December 2012...accurate and meaningful conclusions from such a large amount of data is a growing problem, and the term “ Big Data ” describes this phenomenon. Big Data ...is “ Big Data ”. 2. HISTORY OF BIG DATA The technology research firm International Data Corporation (IDC) recently performed a study on digital
Cardiovascular simulator improvement: pressure versus volume loop assessment.
Fonseca, Jeison; Andrade, Aron; Nicolosi, Denys E C; Biscegli, José F; Leme, Juliana; Legendre, Daniel; Bock, Eduardo; Lucchi, Julio Cesar
2011-05-01
This article presents improvement on a physical cardiovascular simulator (PCS) system. Intraventricular pressure versus intraventricular volume (PxV) loop was obtained to evaluate performance of a pulsatile chamber mimicking the human left ventricle. PxV loop shows heart contractility and is normally used to evaluate heart performance. In many heart diseases, the stroke volume decreases because of low heart contractility. This pathological situation must be simulated by the PCS in order to evaluate the assistance provided by a ventricular assist device (VAD). The PCS system is automatically controlled by a computer and is an auxiliary tool for VAD control strategies development. This PCS system is according to a Windkessel model where lumped parameters are used for cardiovascular system analysis. Peripheral resistance, arteries compliance, and fluid inertance are simulated. The simulator has an actuator with a roller screw and brushless direct current motor, and the stroke volume is regulated by the actuator displacement. Internal pressure and volume measurements are monitored to obtain the PxV loop. Left chamber internal pressure is directly obtained by pressure transducer; however, internal volume has been obtained indirectly by using a linear variable differential transformer, which senses the diaphragm displacement. Correlations between the internal volume and diaphragm position are made. LabVIEW integrates these signals and shows the pressure versus internal volume loop. The results that have been obtained from the PCS system show PxV loops at different ventricle elastances, making possible the simulation of pathological situations. A preliminary test with a pulsatile VAD attached to PCS system was made. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Pituitary Volume Prospectively Predicts Internalizing Symptoms in Adolescence
ERIC Educational Resources Information Center
Zipursky, Amy R.; Whittle, Sarah; Yucel, Murat; Lorenzetti, Valentina; Wood, Stephen J.; Lubman, Dan I.; Simmons, Julian G.; Allen, Nicholas B.
2011-01-01
Background: Early adolescence is a critical time for the development of both internalizing and externalizing disorders. We aimed to investigate whether pituitary volume, an index of hypothalamic-pituitary-adrenal (HPA) axis function, represents a vulnerability factor for the emergence of internalizing and externalizing symptoms during adolescence…
Revealing pMDI Spray Initial Conditions: Flashing, Atomisation and the Effect of Ethanol
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mason-Smith, Nicholas; Duke, Daniel J.; Kastengren, Alan L.
Sprays from pressurised metered-dose inhalers are produced by a transient discharge of a multiphase mixture. Small length and short time scales have made the investigation of the governing processes difficult. Consequently, a deep understanding of the physical processes that govern atomisation and drug particle formation has been elusive. X-ray phase contrast imaging and quantitative radiography were used to reveal the internal flow structure and measure the time-variant nozzle exit mass density of 50 µL metered sprays of HFA134a, with and without ethanol cosolvent. Internal flow patterns were imaged at a magnification of 194 pixels/mm and 7759 frames per second withmore » 150 ps temporal resolution. Spray projected mass was measured with temporal resolution of 1 ms and spatial resolution 6 µm × 5 µm. The flow upstream of the nozzle comprised large volumes of vapour at all times throughout the injection. The inclusion of ethanol prevented bubble coalescence, altering the internal flow structure and discharge. Radiography measurements confirmed that the nozzle exit area is dominantly occupied by vapour, with a peak liquid volume fraction of 13%. Vapour generation in pMDIs occurs upstream of the sump, and the dominant volume component in the nozzle exit orifice is vapour at all times in the injection. Furthermore, the flow in ethanol-containing pMDIs has a bubbly structure resulting in a comparatively stable discharge, whereas the binary structure of propellant-only flows results in unsteady discharge and the production of unrespirable liquid masses.« less
Revealing pMDI Spray Initial Conditions: Flashing, Atomisation and the Effect of Ethanol.
Mason-Smith, Nicholas; Duke, Daniel J; Kastengren, Alan L; Traini, Daniela; Young, Paul M; Chen, Yang; Lewis, David A; Edgington-Mitchell, Daniel; Honnery, Damon
2017-04-01
Sprays from pressurised metered-dose inhalers are produced by a transient discharge of a multiphase mixture. Small length and short time scales have made the investigation of the governing processes difficult. Consequently, a deep understanding of the physical processes that govern atomisation and drug particle formation has been elusive. X-ray phase contrast imaging and quantitative radiography were used to reveal the internal flow structure and measure the time-variant nozzle exit mass density of 50 µL metered sprays of HFA134a, with and without ethanol cosolvent. Internal flow patterns were imaged at a magnification of 194 pixels/mm and 7759 frames per second with 150 ps temporal resolution. Spray projected mass was measured with temporal resolution of 1 ms and spatial resolution 6 µm × 5 µm. The flow upstream of the nozzle comprised large volumes of vapour at all times throughout the injection. The inclusion of ethanol prevented bubble coalescence, altering the internal flow structure and discharge. Radiography measurements confirmed that the nozzle exit area is dominantly occupied by vapour, with a peak liquid volume fraction of 13%. Vapour generation in pMDIs occurs upstream of the sump, and the dominant volume component in the nozzle exit orifice is vapour at all times in the injection. The flow in ethanol-containing pMDIs has a bubbly structure resulting in a comparatively stable discharge, whereas the binary structure of propellant-only flows results in unsteady discharge and the production of unrespirable liquid masses.
Revealing pMDI Spray Initial Conditions: Flashing, Atomisation and the Effect of Ethanol
Mason-Smith, Nicholas; Duke, Daniel J.; Kastengren, Alan L.; ...
2017-01-17
Sprays from pressurised metered-dose inhalers are produced by a transient discharge of a multiphase mixture. Small length and short time scales have made the investigation of the governing processes difficult. Consequently, a deep understanding of the physical processes that govern atomisation and drug particle formation has been elusive. X-ray phase contrast imaging and quantitative radiography were used to reveal the internal flow structure and measure the time-variant nozzle exit mass density of 50 µL metered sprays of HFA134a, with and without ethanol cosolvent. Internal flow patterns were imaged at a magnification of 194 pixels/mm and 7759 frames per second withmore » 150 ps temporal resolution. Spray projected mass was measured with temporal resolution of 1 ms and spatial resolution 6 µm × 5 µm. The flow upstream of the nozzle comprised large volumes of vapour at all times throughout the injection. The inclusion of ethanol prevented bubble coalescence, altering the internal flow structure and discharge. Radiography measurements confirmed that the nozzle exit area is dominantly occupied by vapour, with a peak liquid volume fraction of 13%. Vapour generation in pMDIs occurs upstream of the sump, and the dominant volume component in the nozzle exit orifice is vapour at all times in the injection. Furthermore, the flow in ethanol-containing pMDIs has a bubbly structure resulting in a comparatively stable discharge, whereas the binary structure of propellant-only flows results in unsteady discharge and the production of unrespirable liquid masses.« less
Frye, K. J.; Royer, C. A.
1998-01-01
The structural origin of the decrease in system volume upon protein denaturation by pressure has remained a puzzle for decades. This negative volume change upon unfolding is assumed to arise globally from more intimate interactions between the polypeptide chain and water, including electrostriction of buried charges that become exposed upon unfolding, hydration of the polypeptide backbone and amino acid side chains and elimination of packing defects and internal void volumes upon unfolding of the chain. However, the relative signs and magnitudes of each of these contributing factors have not been experimentally determined. Our laboratory has probed the fundamental basis for the volume change upon unfolding of staphylococcal nuclease (Snase) using variable solution conditions and point mutants of Snase (Royer CA et al., 1993, Biochemistry 32:5222-5232; Frye KJ et al., 1996, Biochemistry 35:10234-10239). Our prior results indicate that for Snase, neither electrostriction nor polar or nonpolar hydration contributes significantly to the value of the volume change of unfolding. In the present work, we investigate the pressure induced unfolding of three point mutants of Snase in which internal cavity size is altered. The experimentally determined volume changes of unfolding for the mutants suggest that loss of internal void volume upon unfolding represents the major contributing factor to the value of the volume change of Snase unfolding. PMID:9792110
International and Intercultural Communication Annual, Volume VI, December 1982.
ERIC Educational Resources Information Center
Jain, Nemi C., Ed.
Designed to serve as a forum for the exchange of ideas concerning international and intercultural communication, this annual volume contains articles that cover a variety of topics. The first half of the volume contains seven articles discussing the following: (1) a pragmatic approach to mass media development in three models of developing…
Opportunities in Total Knee Arthroplasty: Worldwide Surgeons' Perspective.
Dunbar, Michael; Newman, Jared M; Khlopas, Anton; Chughtai, Morad; Martinez, Nick; Bhowmik-Stoker, Manoshi; Mont, Michael A
2017-07-25
This study surveyed a group of US and international orthopaedic surgeons to prioritize areas of improvement in primary total knee arthroplasty (TKA). Specifically, we assessed surgeon responses regarding the top five areas of TKA needing improvement; which were stratified by: a) US surgeons, b) international surgeons, c) US surgeons' implant-brand-loyalty, and d) surgeons' years of experience and case volume. Four hundred and eighteen surgeons who were board-certified, in practice for at least two years, spent 60% of their time in clinical practice, and performed a minimum of 25 lower extremity joint arthroplasties per year were surveyed. They chose the top five areas (among 17) needing improvement for TKA. Results were stratified by surgeons' location (US and international), implant-brand-loyalty, years of experience, and case volume. Functional outcomes was the top identified area for improvement (US 63% and international 71%), followed by brand loyalty (Company I 68%, other brand 59%, and multi-brand/no loyalty 66%), years of experience (early-career 64%, mid-career 63%, and late-career 75%) and case volume (low-volume 69%, mid-volume 60%, and high-volume 71%). Following this was costs for US surgeons (47%) and implant survivorship for international surgeons (57%). While costs were the next highest area for specific Company-loyal surgeons (57%), implant survivorship was the next highest area for the other two cohorts. Implant survivorship was the second most important area of improvement regardless of years of experience and for low- and mid-volume surgeons. Surgeons identified functional outcomes as the most important area needing improvement. Cost of implants was more important for American as compared to international surgeons.
Advances in Wilms Tumor Treatment and Biology: Progress Through International Collaboration.
Dome, Jeffrey S; Graf, Norbert; Geller, James I; Fernandez, Conrad V; Mullen, Elizabeth A; Spreafico, Filippo; Van den Heuvel-Eibrink, Marry; Pritchard-Jones, Kathy
2015-09-20
Clinical trials in Wilms tumor (WT) have resulted in overall survival rates of greater than 90%. This achievement is especially remarkable because improvements in disease-specific survival have occurred concurrently with a reduction of therapy for large patient subgroups. However, the outcomes for certain patient subgroups, including those with unfavorable histologic and molecular features, bilateral disease, and recurrent disease, remain well below the benchmark survival rate of 90%. Therapy for WT has been advanced in part by an increasingly complex risk-stratification system based on patient age; tumor stage, histology, and volume; response to chemotherapy; and loss of heterozygosity at chromosomes 1p and 16q. A consequence of this system has been the apportionment of patients into such small subgroups that only collaboration between large international WT study groups will support clinical trials that are sufficiently powered to answer challenging questions that move the field forward. This article gives an overview of the Children's Oncology Group and International Society of Pediatric Oncology approaches to WT and focuses on four subgroups (stage IV, initially inoperable, bilateral, and relapsed WT) for which international collaboration is pressing. In addition, biologic insights resulting from collaborative laboratory research are discussed. A coordinated expansion of international collaboration in both clinical trials and laboratory science will provide real opportunity to improve the treatment and outcomes for children with renal tumors on a global level. © 2015 by American Society of Clinical Oncology.
Automatic segmentation of tumor-laden lung volumes from the LIDC database
NASA Astrophysics Data System (ADS)
O'Dell, Walter G.
2012-03-01
The segmentation of the lung parenchyma is often a critical pre-processing step prior to application of computer-aided detection of lung nodules. Segmentation of the lung volume can dramatically decrease computation time and reduce the number of false positive detections by excluding from consideration extra-pulmonary tissue. However, while many algorithms are capable of adequately segmenting the healthy lung, none have been demonstrated to work reliably well on tumor-laden lungs. Of particular challenge is to preserve tumorous masses attached to the chest wall, mediastinum or major vessels. In this role, lung volume segmentation comprises an important computational step that can adversely affect the performance of the overall CAD algorithm. An automated lung volume segmentation algorithm has been developed with the goals to maximally exclude extra-pulmonary tissue while retaining all true nodules. The algorithm comprises a series of tasks including intensity thresholding, 2-D and 3-D morphological operations, 2-D and 3-D floodfilling, and snake-based clipping of nodules attached to the chest wall. It features the ability to (1) exclude trachea and bowels, (2) snip large attached nodules using snakes, (3) snip small attached nodules using dilation, (4) preserve large masses fully internal to lung volume, (5) account for basal aspects of the lung where in a 2-D slice the lower sections appear to be disconnected from main lung, and (6) achieve separation of the right and left hemi-lungs. The algorithm was developed and trained to on the first 100 datasets of the LIDC image database.
International migration: an assessment for the '90s.
Tomasi, S M
1989-01-01
A quarter century ago, the world of international migration looked much different than it does today. International migration was then favorable regarded in many parts of the world. Today, this mood has soured. Guestworkers in Germany in 1989, particularly Turks, are the subject of widespread hostility and a growing anti-immigrant political party. France, too, has developed a significant anti-immigrant political party and now facilitates the repatriation of unemployed Algerian nationals with cash assistance. In the US, a chapter thought closed forever in 1964 might well be reopened as the federal government, in 1989, will decide whether or not to admit replenishment agricultural workers. In the Arab region, the Palestine Liberation Organization was created in 1964 to represent one of the world's largest refugee population - the 1 million Palestinians who fled during the 1'947-1949 fighting and their offspring. Today, Africa contains an estimated 4-5 million refugees. In Asia, the Gulf of Tonkin crisis in 1964 served as a pretext to escalate the war in Indochina that would create millions of refugees. Little concern was expressed 25 years ago about illegal migration from developing countries. Asia, Africa, and Latin America seemed to lie outside the usual path of international migration. A conference on international migration was held at Bellagio, Italy, in July 1988. The contributions comprising this volume were presented at the Bellagio Conference. Each contribution approaches the subject matter of international migration from a distinctive theoretical, disciplinary, or thematic perspective. This volume therefore reflects a large measure of the scholarly diversity that coexists in international migration studies. One of the themes of the conference is the realization that states vitally affect international migration and are greatly affected by the phenomenon. The Bellagio conferees also agreed on the importance of comparative research to greater scientific understanding of international migration. In a world of increasing interdependency, the inevitable effect of a knowledge shortfall is a glaring gap in understanding.
Neutron Imaging for Selective Laser Melting Inconel Hardware with Internal Passages
NASA Technical Reports Server (NTRS)
Tramel, Terri L.; Norwood, Joseph K.; Bilheux, Hassina
2014-01-01
Additive Manufacturing is showing great promise for the development of new innovative designs and large potential life cycle cost reduction for the Aerospace Industry. However, more development work is required to move this technology into space flight hardware production. With selective laser melting (SLM), hardware that once consisted of multiple, carefully machined and inspected pieces, joined together can be made in one part. However standard inspection techniques cannot be used to verify that the internal passages are within dimensional tolerances or surface finish requirements. NASA/MSFC traveled to Oak Ridge National Lab's (ORNL) Spallation Neutron Source to perform some non-destructive, proof of concept imaging measurements to assess the capabilities to understand internal dimensional tolerances and internal passages surface roughness. This presentation will describe 1) the goals of this proof of concept testing, 2) the lessons learned when designing and building these Inconel 718 test specimens to minimize beam time, 3) the neutron imaging test setup and test procedure to get the images, 4) the initial results in images, volume and a video, 4) the assessment of using this imaging technique to gather real data for designing internal flow passages in SLM manufacturing aerospace hardware, and lastly 5) how proper cleaning of the internal passages is critically important. In summary, the initial results are very promising and continued development of a technique to assist in SLM development for aerospace components is desired by both NASA and ORNL. A plan forward that benefits both ORNL and NASA will also be presented, based on the promising initial results. The initial images and volume reconstruction showed that clean, clear images of the internal passages geometry are obtainable. These clear images of the internal passages of simple geometries will be compared to the build model to determine any differences. One surprising result was that a new cleaning process was used on these simply geometric specimens that resulted in what appears to be very smooth internal surfaces, when compared to other aerospace hardware cleaning methods.
The Role of NOAA's National Data Centers in the Earth and Space Science Infrastructure
NASA Astrophysics Data System (ADS)
Fox, C. G.
2008-12-01
NOAA's National Data Centers (NNDC) provide access to long-term archives of environmental data from NOAA and other sources. The NNDCs face significant challenges in the volume and complexity of modern data sets. Data volume challenges are being addressed using more capable data archive systems such as the Comprehensive Large Array-Data Stewardship System (CLASS). Challenges in assuring data quality and stewardship are in many ways more challenging. In the past, scientists at the Data Centers could provide reasonable stewardship of data sets in their area of expertise. As staff levels have decreased and data complexity has increased, Data Centers depend on their data providers and user communities to provide high-quality metadata, feedback on data problems and improvements. This relationship requires strong partnerships between the NNDCs and academic, commercial, and international partners, as well as advanced data management and access tools that conform to established international standards when available. The NNDCs are looking to geospatial databases, interactive mapping, web services, and other Application Program Interface approaches to help preserve NNDC data and information and to make it easily available to the scientific community.
Horga, Guillermo; Bernacer, Javier; Dusi, Nicola; Entis, Jonathan; Chu, Kingwai; Hazlett, Erin A; Haznedar, M Mehmet; Kemether, Eileen; Byne, William; Buchsbaum, Monte S
2011-10-01
Ventricular enlargement is one of the most consistent abnormal structural brain findings in schizophrenia and has been used to infer brain shrinkage. However, whether ventricular enlargement is related to local overlying cortex and/or adjacent subcortical structures or whether it is related to brain volume change globally has not been assessed. We systematically assessed interrelations of ventricular volumes with gray and white matter volumes of 40 Brodmann areas (BAs), the thalamus and its medial dorsal nucleus and pulvinar, the internal capsule, caudate and putamen. We acquired structural MRI ( patients with schizophrenia (n = 64) and healthy controls (n = 56)) and diffusion tensor fractional anisotropy (FA) (untreated schizophrenia n = 19, controls n = 32). Volumes were assessed by manual tracing of central structures and a semi-automated parcellation of BAs. Patients with schizophrenia had increased ventricular size associated with decreased cortical gray matter volumes widely across the brain; a similar but less pronounced pattern was seen in normal controls; local correlations (e.g. temporal horn with temporal lobe volume) were not appreciably higher than non-local correlations (e.g. temporal horn with prefrontal volume). White matter regions adjacent to the ventricles similarly did not reveal strong regional relationships. FA and center of mass of the anterior limb of the internal capsule also appeared differentially influenced by ventricular volume but findings were similarly not regional. Taken together, these findings indicate that ventricular enlargement is globally interrelated with gray matter volume diminution but not directly correlated with volume loss in the immediately adjacent caudate, putamen, or internal capsule.
Xu, Ming; Lei, Zhipeng; Yang, James
2015-01-01
N95 filtering facepiece respirator (FFR) dead space is an important factor for respirator design. The dead space refers to the cavity between the internal surface of the FFR and the wearer's facial surface. This article presents a novel method to estimate the dead space volume of FFRs and experimental validation. In this study, six FFRs and five headforms (small, medium, large, long/narrow, and short/wide) are used for various FFR and headform combinations. Microsoft Kinect Sensors (Microsoft Corporation, Redmond, WA) are used to scan the headforms without respirators and then scan the headforms with the FFRs donned. The FFR dead space is formed through geometric modeling software, and finally the volume is obtained through LS-DYNA (Livermore Software Technology Corporation, Livermore, CA). In the experimental validation, water is used to measure the dead space. The simulation and experimental dead space volumes are 107.5-167.5 mL and 98.4-165.7 mL, respectively. Linear regression analysis is conducted to correlate the results from Kinect and water, and R(2) = 0.85.
ERIC Educational Resources Information Center
Meserole, Harrison T., Comp.
Volume 1 of the 4-volume, international bibliography contains some 9,000 entries referring to books and articles which focus on general, English, American, medieval and neo-Latin, and Celtic literatures. The master list of the nearly 1,500 periodicals from which entries are derived is furnished at the beginning of the volume with a table of…
A low-volume cavity ring-down spectrometer for sample-limited applications
NASA Astrophysics Data System (ADS)
Stowasser, C.; Farinas, A. D.; Ware, J.; Wistisen, D. W.; Rella, C.; Wahl, E.; Crosson, E.; Blunier, T.
2014-08-01
In atmospheric and environmental sciences, optical spectrometers are used for the measurements of greenhouse gas mole fractions and the isotopic composition of water vapor or greenhouse gases. The large sample cell volumes (tens of milliliters to several liters) in commercially available spectrometers constrain the usefulness of such instruments for applications that are limited in sample size and/or need to track fast variations in the sample stream. In an effort to make spectrometers more suitable for sample-limited applications, we developed a low-volume analyzer capable of measuring mole fractions of methane and carbon monoxide based on a commercial cavity ring-down spectrometer. The instrument has a small sample cell (9.6 ml) and can selectively be operated at a sample cell pressure of 140, 45, or 20 Torr (effective internal volume of 1.8, 0.57, and 0.25 ml). We present the new sample cell design and the flow path configuration, which are optimized for small sample sizes. To quantify the spectrometer's usefulness for sample-limited applications, we determine the renewal rate of sample molecules within the low-volume spectrometer. Furthermore, we show that the performance of the low-volume spectrometer matches the performance of the standard commercial analyzers by investigating linearity, precision, and instrumental drift.
Cortical Changes Across the Autism Lifespan.
Osipowicz, Karol; Bosenbark, Danielle D; Patrick, Kristina E
2015-08-01
Although it is widely accepted that autism spectrum disorder (ASD) involves neuroanatomical abnormalities and atypical neurodevelopmental patterns, there is little consensus regarding the precise pattern of neuroanatomical differences or how these differences relate to autism symptomology. Furthermore, there is limited research related to neuroanatomical correlates of autism symptomology in individuals with ASD and the studies that do exist primarily include small samples. This study was the first to investigate gray matter (GM) changes throughout the ASD lifespan, using voxel-based morphometry to determine whether significant differences exist in the GM volumes of a large sample of individuals with ASD compared to age- and IQ-matched typical controls. We examined GM volume across the lifespan in 531 individuals diagnosed with ASD and 571 neurotypical controls, aged 7-64. We compared groups and correlated GM with age and autism severity in the ASD group. Findings suggest bilateral decreased GM volume for individuals with ASD in regions extending from the thalamus to the cerebellum, anterior medial temporal lobes, and orbitofrontal regions. Higher autism severity was associated with decreased GM volumes in prefrontal cortex, inferior parietal and temporal regions, and temporal poles. Similar relationships were found between GM volume and age. ASD diagnosis and severity were not associated with increased GM volumes in any region. © 2015 International Society for Autism Research, Wiley Periodicals, Inc.
Military Review, October 1991. Volume 71, Number 10
1991-10-01
National Guard Ueutenant Colonel Juan M. Gallardo Chilean Army Spanish Edition 45 Senior Leader Vision: The Case of By Order of the Secretary of the...sobering. Our Army and our nation de- in the 1986 version of FvI 100-5 is largely con- mand our full attention. MR NOTES 1 Michael Howard, "Military...of our victory in serving full time in selected key positions. Tiev L-the gulf, we should ,lso realize that the war provide an internal structure
1989-10-01
Vol. 18, No. 5, 1975, pp. 253-263. [CAR84] D.B. Carlin, J.P. Bednarz, CJ. Kaiser, J.C. Connolly, M.G. Harvey , "Multichannel optical recording using... Kellog [31] takes a similar approach as ILEX in the sense that it uses existing systems rather than developing specialized hardwares (the Xerox 1100...parallel complexity. In Proceedings of the International Conference on Database Theory, pages 1-30, September 1986. [31] C. Kellog . From data management to
Microgravity Science Glovebox - Working Volume
NASA Technical Reports Server (NTRS)
1997-01-01
Access ports, one on each side of the Microgravity Science Glovebox (MSG), will allow scientists to place large experiment items inside the MSG. The ports also provide additional glove ports (silver disk) for greater access to the interior. The European Space Agency (ESA) and NASA are developing the MSG for use aboard the International Space Station (ISS). Scientists will use the MSG to carry out multidisciplinary studies in combustion science, fluid physics and materials science. The MSG is managed by NASA's Marshall Space Flight Center (MSFC). Photo Credit: NASA/MSFC
1992-06-01
Large scale data collection activities began with the installation of several sensor systems at the John F. Kennedy International Airport ( JFK ) in June... airport in 1989 (Figure 2). It assists the controllers in the management of the arrival traffic by the provision of an optimized plan for the incoming...Vzf t GOAL ---- > MINIMIZE jVref -Vesti BY OPTIMIZING SENSOR PARAMETERS AND TAKING IN ACCOUNT CUMBERNESS AND ENVIRONMENTAL CONSTRAINTS AIRPORT TESTS
1979-07-02
modulation falls off at -30 dB per oc- tave as would be expected for internal waves. jloat: (C) (1) Random course and speed produce small effect on coherence...2) Constant course and speed produce large effects. (3) Measured coherence lower than predicted. Barbour: (C) Standard deviation of fluctuations in...present characteristics of signals propagated over long range deep water paths, for which the data is currently insufficient to permit modeling. In
Al-Jumaian, Nasser; Malik, Rizwan; Khandekar, Rajiv; Al-Humaidan, Abdullah; Al-Madany, Rana; Al-Qahtani, Reham; Altowairqi, Ahmed; Al-Theeb, Abdulwahab; Zaman, Babar; Al-Djasim, Leyla; Craven, E. Randy; Edward, Deepak P.
2016-01-01
WHAT IS KNOWN AND OBJECTIVE: Physical bottle characteristics differ of brand name topical glaucoma medications and local generic equivalents. This study compares the bottle characteristics of international topical glaucoma brands versus local brands from the Kingdom of Saudi Arabia. METHODS: Data were collected on bottle drum volume, drop volume, bottle squeezability, bottle tip diameter, labels and instructions, cap color coding, and clarity of the drug label. Density-based calculations of drops in bottle volume were assessed using an analytic balance. Bottle tip diameter was measured using 0.05 mm Vernier calipers. A Likert scale-based questionnaire was used to evaluate the subjective opinions of patients on bottle squeezability, clarity of usage and storage instructions, and the consistency of the cap color coding. RESULTS: The volumes of international brands were statistically significantly higher than the local brands (P < 0.001). A number of drops per bottle and tip diameter were comparable between the international local brands. Cap color coding was inconsistent for international and local brands. Patients were dissatisfied with the label font size. Patients reported that the international and local brands were similar in terms of the ease of opening the bottle, instilling a drop, and the clarity of the instructions; but the local brands were subjectively easier to squeeze than international brands. WHAT IS NEW AND CONCLUSIONS: This is the first study to compare bottle characteristics of local Saudi Arabia brands with international brands. The bottle characteristics and patient feedback were similar between the local and international topical glaucoma medications. However, there were differences between the local and international brands in drug volume, bottle squeezability. Hence, patient compliance and drop dosage may differ based on the origin of manufacture. PMID:27994392
Nineteenth International Cosmic Ray Conference. OG Sessions, Volume 3
NASA Technical Reports Server (NTRS)
Jones, F. C. (Compiler)
1985-01-01
Papers submitted for presentation at the 19th International Cosmic Ray Conference are compiled. This volume addresses cosmic ray sources and acceleration, interstellar propagation and nuclear interactions, and detection techniques and instrumentation.
Large-Scale Trade in Legally Protected Marine Mollusc Shells from Java and Bali, Indonesia.
Nijman, Vincent; Spaan, Denise; Nekaris, K Anne-Isola
2015-01-01
Tropical marine molluscs are traded globally. Larger species with slow life histories are under threat from over-exploitation. We report on the trade in protected marine mollusc shells in and from Java and Bali, Indonesia. Since 1987 twelve species of marine molluscs are protected under Indonesian law to shield them from overexploitation. Despite this protection they are traded openly in large volumes. We collected data on species composition, origins, volumes and prices at two large open markets (2013), collected data from wholesale traders (2013), and compiled seizure data by the Indonesian authorities (2008-2013). All twelve protected species were observed in trade. Smaller species were traded for
ERIC Educational Resources Information Center
Chigisheva, Oksana, Ed.; Popov, Nikolay, Ed.
2015-01-01
This proceedings is divided into two parts. Volume 13, Number 1 contains papers presented at the thirteenth annual international conference of the Bulgarian Comparative Education Society (BCES) held in Sofia, Bulgaria June 10-13, 2015. Volume 13, Number 2 contains papers presented at the third International Partner Conference, organised by the…
ERIC Educational Resources Information Center
Schaumann, Leif
Intended as a companion piece to volume 7 in the Method Series, Pharmaceutical Supply System Planning (CE 024 234), this fifth of six volumes in the International Health Planning Reference Series is a combined literature review and annotated bibliography dealing with alternative methodologies for planning and analyzing pharmaceutical supply…
World Energy Data System (WENDS). Volume I. Country data, AF-CO
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1979-06-01
The World Energy Data System contains organized data on those countries and international organizations that may have critical impact on the world energy scene. Volumes 1 through 4 include energy-related information concerning 57 countries. Additional volumes (5 through 11) present review information on international organizations, summaries of energy-related international agreements, and fact sheets on nuclear facilities. Country data on Afghanistan, Algeria, Argentina, Australia, Austria, Bangladesh, Belgium, Bolivia, Brazil, Burma, Canada, China, and Colombia are included in Volume 1. The following topics are covered for most of the countries: economic, demographic, and educational profiles; energy policy; indigenous energy resources and uses;more » forecasts, demand, exports, imports of energy supplies; environmental considerations; power production facilities; energy industries; commercial applications of energy; research and development activities of energy; and international activities.« less
Education in One World: Perspectives from Different Nations. BCES Conference Books, Volume 11
ERIC Educational Resources Information Center
Popov, Nikolay, Ed.; Wolhuter, Charl, Ed.; Almeida, Patrícia Albergaria, Ed.; Hilton, Gillian, Ed.; Ogunleye, James, Ed.; Chigisheva, Oksana, Ed.
2013-01-01
This volume contains papers submitted to the 11th Annual International Conference of the Bulgarian Comparative Education Society (BCES), held in Plovdiv, Bulgaria, 14-17 May 2013, and papers submitted to the 1st International Distance Partner Conference, organized by the International Research Centre "Scientific Cooperation,"…
NASA Astrophysics Data System (ADS)
Koster, Kay; Erkens, Gilles; Zwanenburg, Cor
2016-04-01
It is undisputed that land subsidence threatens coastal-deltaic lowlands all over the world. Any loss of elevation (on top of sea level rise) increases flood risk in these lowlands, and differential subsidence may cause damage to infrastructure and constructions. Many of these settings embed substantial amounts of peat, which is, due to its mechanically weak organic composition, one of the main drivers of subsidence. Peat is very susceptible to volume reduction by loading and drainage induced consolidation, which dissipates pore water, resulting in a tighter packing of the organic components. Often, the current state of consolidation of peat embedded within coastal-deltaic subsidence hotspots (e.g. Venice lagoon, Mississippi delta, San Joaquin delta, Kalimantan peatlands), is somewhere between its initial (natural) and maximum compressed stage. Quantifying the current state regarding peat volume loss, is of utmost importance to predict potential (near) future subsidence when draining or loading an area. The processes of subsidence often afflict large areas (>103 km2), thus demanding large datasets to assess the current state of the subsurface. In contrast to data describing the vertical motions of the actual surface (geodesy, satellite imagery), subsurface information applicable for subsidence analysis are often lacking in subsiding deltas. This calls for new initiatives to bridge that gap. Here we introduce Cone Penetration Testing (CPT) to quantify the amount of volume loss peat layers embedded within the Holland coastal plain (the Netherlands) experienced. CPT measures soil mechanical strength, and hundreds of thousands of CPTs are conducted each year on all continents. We analyzed 28 coupled CPT-borehole observations, and found strong empirical relations between volume loss and increased peat mechanical strength. The peat lost between ~20 - 95% of its initial thickness by dissipation of excess pore water. An increase in 0.1 - 0.4 MPa of peat strength is accountable for 20 - 75 % of the volume loss, and 0.4 - 0.7 MPa for 75 - 95 % volume loss. This indicates that large amounts of volume by water dissipation has to be lost, before peat experiences a serious increase in strength, which subsequently continuous to increase with only small amount of volume loss. To demonstrate the robustness of our approach to the international field of land subsidence, we applied the obtained empirical relations to previously published CPT logs deriving from the peat-rich San Joaquin-Sacramento delta and the Kalimantan peatlands, and found volume losses that correspond with previously published results. Furthermore, we used the obtained results to predict maximum surface lowering for these areas by consolidation. In conclusion, these promising results and its worldwide popularity yielding large datasets, open the door for CPT as a generic method to contribute to quantifying the imminent threat of coastal-deltaic land subsidence.
Similarity in Bilateral Isolated Internal Orbital Fractures.
Chen, Hung-Chang; Cox, Jacob T; Sanyal, Abanti; Mahoney, Nicholas R
2018-04-13
In evaluating patients sustaining bilateral isolated internal orbital fractures, the authors have observed both similar fracture locations and also similar expansion of orbital volumes. In this study, we aim to investigate if there is a propensity for the 2 orbits to fracture in symmetrically similar patterns when sustaining similar trauma. A retrospective chart review was performed studying all cases at our institution of bilateral isolated internal orbital fractures involving the medial wall and/or the floor at the time of presentation. The similarity of the bilateral fracture locations was evaluated using the Fisher's exact test. The bilateral expanded orbital volumes were analyzed using the Wilcoxon signed-rank test to assess for orbital volume similarity. Twenty-four patients with bilateral internal orbital fractures were analyzed for fracture location similarity. Seventeen patients (70.8%) had 100% concordance in the orbital subregion fractured, and the association between the right and the left orbital fracture subregion locations was statistically significant (P < 0.0001). Fifteen patients were analyzed for orbital volume similarity. The average orbital cavity volume was 31.2 ± 3.8 cm on the right and 32.0 ± 3.7 cm on the left. There was a statistically significant difference between right and left orbital cavity volumes (P = 0.0026). The data from this study suggest that an individual who suffers isolated bilateral internal orbital fractures has a statistically significant similarity in the location of their orbital fractures. However, there does not appear to be statistically significant similarity in the expansion of the orbital volumes in these patients.
International Linear Collider Technical Design Report (Volumes 1 through 4)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harrison M.
2013-03-27
The design report consists of four volumes: Volume 1, Executive Summary; Volume 2, Physics; Volume 3, Accelerator (Part I, R and D in the Technical Design Phase, and Part II, Baseline Design); and Volume 4, Detectors.
Balloon-Assisted Occlusion of the Internal Iliac Arteries in Patients with Placenta Accreta/Percreta
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bodner, Leonard J.; Nosher, John L.; Gribbin, Christopher
2006-06-15
Background. Placenta accreta/percreta is a leading cause of third trimester hemorrhage and postpartum maternal death. The current treatment for third trimester hemorrhage due to placenta accreta/percreta is cesarean hysterectomy, which may be complicated by large volume blood loss. Purpose. To determine what role, if any, prophylactic temporary balloon occlusion and transcatheter embolization of the anterior division of the internal iliac arteries plays in the management of patients with placenta accreta/percreta. Methods. The records of 28 consecutive patients with a diagnosis of placenta accreta/percreta were retrospectively reviewed. Patients were divided into two groups. Six patients underwent prophylactic temporary balloon occlusion, followedmore » by cesarean section, transcatheter embolization of the anterior division of the internal iliac arteries and cesarean hysterectomy (n = 5) or uterine curettage (n = 1). Twenty-two patients underwent cesarean hysterectomy without endovascular intervention. The following parameters were compared in the two groups: patient age, gravidity, parity, gestational age at delivery, days in the intensive care unit after delivery, total hospital days, volume of transfused blood products, volume of fluid replacement intraoperatively, operating room time, estimated blood loss, and postoperative morbidity and mortality. Results. Patients in the embolization group had more frequent episodes of third trimester bleeding requiring admission and bedrest prior to delivery (16.7 days vs. 2.9 days), resulting in significantly more hospitalization time in the embolization group (23 days vs. 8.8 days) and delivery at an earlier gestational age than in those in the surgical group (32.5 weeks). There was no statistical difference in mean estimated blood loss, volume of replaced blood products, fluid replacement needs, operating room time or postoperative recovery time. Conclusion. Our findings do not support the contention that in patients with placenta accreta/percreta, prophylactic temporary balloon occlusion and embolization prior to hysterectomy diminishes intraoperative blood loss.« less
Nineteenth International Cosmic Ray Conference. HE Sessions, Volume 7
NASA Technical Reports Server (NTRS)
Jones, F. C. (Compiler)
1985-01-01
Papers submitted for presentation at the 19th International Cosmic ray Conference are compiled. This volume contains papers which address various aspects of extensive air showers (EAS) produced by energetic particles and gamma rays.
Cellular packing, mechanical stress and the evolution of multicellularity
NASA Astrophysics Data System (ADS)
Jacobeen, Shane; Pentz, Jennifer T.; Graba, Elyes C.; Brandys, Colin G.; Ratcliff, William C.; Yunker, Peter J.
2018-03-01
The evolution of multicellularity set the stage for sustained increases in organismal complexity1-5. However, a fundamental aspect of this transition remains largely unknown: how do simple clusters of cells evolve increased size when confronted by forces capable of breaking intracellular bonds? Here we show that multicellular snowflake yeast clusters6-8 fracture due to crowding-induced mechanical stress. Over seven weeks ( 291 generations) of daily selection for large size, snowflake clusters evolve to increase their radius 1.7-fold by reducing the accumulation of internal stress. During this period, cells within the clusters evolve to be more elongated, concomitant with a decrease in the cellular volume fraction of the clusters. The associated increase in free space reduces the internal stress caused by cellular growth, thus delaying fracture and increasing cluster size. This work demonstrates how readily natural selection finds simple, physical solutions to spatial constraints that limit the evolution of group size—a fundamental step in the evolution of multicellularity.
Enhanced vacuum laser-impulse coupling by volume absorption at infrared wavelengths
NASA Astrophysics Data System (ADS)
Phipps, C. R., Jr.; Harrison, R. F.; Shimada, T.; York, G. W.; Turner, R. F.
1990-03-01
This paper reports measurements of vacuum laser impulse coupling coefficients as large as 90 dyne/W, obtained with single microsec-duration CO2 laser pulses incident on a volume-absorbing, cellulose-nitrate-based plastic. This result is the largest coupling coefficient yet reported at any wavelength for a simple, planar target in vacuum, and partly results from expenditure of internal chemical energy in this material. Enhanced coupling was also observed in several other target materials that are chemically passive, but absorb light in depth at 10- and 3-micron wavelengths. The physical distinctions are discussed between this important case and that of simple, planar surface absorbers (such as metals) which were studied in the same experimental series, in light of the predictions of a simple theoretical model.
Temperature fluctuations inside savanna termite mounds: Do size and plant shade matter?
Ndlovu, M; Pérez-Rodríguez, A
2018-05-01
Mound building termites are key ecosystem engineers of subtropical savanna regions. Mounds allow termites to maintain suitable conditions for termite reproduction and food cultivation ('fungus gardens'). We studied how the internal mound temperature of Macrotermes natalensis, a dominant mound-building termite of the subtropical savanna of southern Africa, responds to a number of environmental variables. We used general additive mixed models (GAMM) to determine how external temperature, mound size (volume) and the amount of vegetation shade affects mound internal temperature over a 24-h period. Internal mound temperature varied daily following changes of the external temperature, although the range of variation was much smaller. Active termite mounds maintained a higher internal temperature than inactive ones, and mound activity reinforced the positive effect of mound size and moderated the negative effect of vegetation shade on internal temperatures. In turn, external temperature fluctuations equally affected active and inactive mounds. Large mounds maintained near optimal internal temperatures compared to smaller sized mounds. We therefore conclude that termite mound size is a stronger determinant of internal mound temperature stability compared to plant shade cover. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Cheng, Ming-Hung; Hsieh, Chih-Min; Hwang, Robert R.; Hsu, John R.-C.
2018-04-01
Numerical simulations are performed to investigate the effects of the initial amplitude and pycnocline thickness on the evolutions of convex mode-2 internal solitary waves propagating on the flat bottom. A finite volume method based on a Cartesian grid system is adopted to solve the Navier-Stokes equations using the improved delayed detached eddy simulation turbulent closure model. Mode-2 internal solitary waves (ISWs) are found to become stable at t = 15 s after lifting a vertical sluice gate by a gravity collapse mechanism. Numerical results from three cases of pycnocline thickness reveal the following: (1) the occurrence of a smooth mode-2 ISW when the wave amplitude is small; (2) the PacMan phenomenon for large amplitude waves; and (3) pseudo vortex shedding in the case of very large amplitudes. In general, basic wave properties (wave amplitude, wave speed, vorticity, and wave energy) increase as the wave amplitude increases for a specific value of the pycnocline thickness. Moreover, the pycnocline thickness chiefly determines the core size of a convex mode-2 ISW, while the step depth (that generates an initial wave amplitude) and offset in pycnocline govern the waveform type during its propagation on the flat bottom.
NASA Technical Reports Server (NTRS)
2001-01-01
Computer-generated drawing shows the relative scale and working space for the Microgravity Science Glovebox (MSG) being developed by NASA and the European Space Agency for science experiments aboard the International Space Station (ISS). The person at the glovebox repesents a 95th percentile American male. The MSG will be deployed first to the Destiny laboratory module and later will be moved to ESA's Columbus Attached Payload Module. Each module will be filled with International Standard Payload Racks (green) attached to standoff fittings (yellow) that hold the racks in position. Destiny is six racks in length. The MSG is being developed by the European Space Agency and NASA to provide a large working volume for hands-on experiments aboard the International Space Station. Scientists will use the MSG to carry out multidisciplinary studies in combustion science, fluid physics and materials science. The MSG is managed by NASA's Marshall Space Flight Center. (Credit: NASA/Marshall)
ERIC Educational Resources Information Center
Franco, Robert W., Ed.; Shimabukuro, James N., Ed.
Part of a four-volume set in which community college educators discuss their efforts to internationalize the educational experience of the students and communities they serve, volume IV in this series focuses on the growing importance of community colleges in providing short-term, intensive training in international business and intercultural…
NASA Astrophysics Data System (ADS)
Holness, Marian B.
2018-06-01
One of the outstanding problems in understanding the behavior of intermediate-to-silicic magmatic systems is the mechanism(s) by which large volumes of crystal-poor rhyolite can be extracted from crystal-rich mushy storage zones in the mid-deep crust. The mechanisms commonly invoked are hindered settling, micro-settling, and compaction. The concept of micro-settling involves extraction of grains from a crystal framework during Ostwald ripening and has been shown to be non-viable in the metallic systems for which it was originally proposed. Micro-settling is also likely to be insignificant in silicic mushes, because ripening rates are slow for quartz and plagioclase, contact areas between grains in a crystal mush are likely to be large, and abundant low-angle grain boundaries promote grain coalescence rather than ripening. Published calculations of melt segregation rates by hindered settling (Stokes settling in a crystal-rich system) neglect all but fluid dynamical interactions between particles. Because tabular silicate minerals are likely to form open, mechanically coherent, frameworks at porosities as high as 75%, settling of single crystals is only likely in very melt-rich systems. Gravitationally-driven viscous compaction requires deformation of crystals by either dissolution-reprecipitation or dislocation creep. There is, as yet, no reported microstructural evidence of extensive, syn-magmatic, internally-generated, viscous deformation in fully solidified silicic plutonic rocks. If subsequent directed searches do not reveal clear evidence for internally-generated buoyancy-driven melt segregation processes, it is likely that other factors, such as rejuvenation by magma replenishment, gas filter-pressing, or externally-imposed stress during regional deformation, are required to segregate large volumes of crystal-poor rhyolitic liquids from crustal mushy zones.
A Mass Computation Model for Lightweight Brayton Cycle Regenerator Heat Exchangers
NASA Technical Reports Server (NTRS)
Juhasz, Albert J.
2010-01-01
Based on a theoretical analysis of convective heat transfer across large internal surface areas, this paper discusses the design implications for generating lightweight gas-gas heat exchanger designs by packaging such areas into compact three-dimensional shapes. Allowances are made for hot and cold inlet and outlet headers for assembly of completed regenerator (or recuperator) heat exchanger units into closed cycle gas turbine flow ducting. Surface area and resulting volume and mass requirements are computed for a range of heat exchanger effectiveness values and internal heat transfer coefficients. Benefit cost curves show the effect of increasing heat exchanger effectiveness on Brayton cycle thermodynamic efficiency on the plus side, while also illustrating the cost in heat exchanger required surface area, volume, and mass requirements as effectiveness is increased. The equations derived for counterflow and crossflow configurations show that as effectiveness values approach unity, or 100 percent, the required surface area, and hence heat exchanger volume and mass tend toward infinity, since the implication is that heat is transferred at a zero temperature difference. To verify the dimensional accuracy of the regenerator mass computational procedure, calculation of a regenerator specific mass, that is, heat exchanger weight per unit working fluid mass flow, is performed in both English and SI units. Identical numerical values for the specific mass parameter, whether expressed in lb/(lb/sec) or kg/(kg/sec), show the dimensional consistency of overall results.
A Mass Computation Model for Lightweight Brayton Cycle Regenerator Heat Exchangers
NASA Technical Reports Server (NTRS)
Juhasz, Albert J.
2010-01-01
Based on a theoretical analysis of convective heat transfer across large internal surface areas, this paper discusses the design implications for generating lightweight gas-gas heat exchanger designs by packaging such areas into compact three-dimensional shapes. Allowances are made for hot and cold inlet and outlet headers for assembly of completed regenerator (or recuperator) heat exchanger units into closed cycle gas turbine flow ducting. Surface area and resulting volume and mass requirements are computed for a range of heat exchanger effectiveness values and internal heat transfer coefficients. Benefit cost curves show the effect of increasing heat exchanger effectiveness on Brayton cycle thermodynamic efficiency on the plus side, while also illustrating the cost in heat exchanger required surface area, volume, and mass requirements as effectiveness is increased. The equations derived for counterflow and crossflow configurations show that as effectiveness values approach unity, or 100 percent, the required surface area, and hence heat exchanger volume and mass tend toward infinity, since the implication is that heat is transferred at a zero temperature difference. To verify the dimensional accuracy of the regenerator mass computational procedure, calculation of a regenerator specific mass, that is, heat exchanger weight per unit working fluid mass flow, is performed in both English and SI units. Identical numerical values for the specific mass parameter, whether expressed in lb/(lb/sec) or kg/ (kg/sec), show the dimensional consistency of overall results.
Decision support system in an international-voice-services business company
NASA Astrophysics Data System (ADS)
Hadianti, R.; Uttunggadewa, S.; Syamsuddin, M.; Soewono, E.
2017-01-01
We consider a problem facing by an international telecommunication services company in maximizing its profit. From voice services by controlling cost and business partnership. The competitiveness in this industry is very high, so that any efficiency from controlling cost and business partnership can help the company to survive in the very high competitiveness situation. The company trades voice traffic with a large number of business partners. There are four trading schemes that can be chosen by this company, namely, flat rate, class tiering, volume commitment, and revenue capped. Each scheme has a specific characteristic on the rate and volume deal, where the last three schemes are regarded as strategic schemes to be offered to business partner to ensure incoming traffic volume for both parties. This company and each business partner need to choose an optimal agreement in a certain period of time that can maximize the company’s profit. In this agreement, both parties agree to use a certain trading scheme, rate and rate/volume/revenue deal. A decision support system is then needed in order to give a comprehensive information to the sales officers to deal with the business partners. This paper discusses the mathematical model of the optimal decision for incoming traffic volume control, which is a part of the analysis needed to build the decision support system. The mathematical model is built by first performing data analysis to see how elastic the incoming traffic volume is. As the level of elasticity is obtained, we then derive a mathematical modelling that can simulate the impact of any decision on trading to the revenue of the company. The optimal decision can be obtained from these simulations results. To evaluate the performance of the proposed method we implement our decision model to the historical data. A software tool incorporating our methodology is currently in construction.
ERIC Educational Resources Information Center
Popov, Nikolay, Ed.; Wolhuter, Charl, Ed.; Kalin, Jana, Ed.; Hilton, Gillian, Ed.; Ogunleye, James, Ed.; Niemczyk, Ewelina, Ed.; Chigisheva, Oksana, Ed.
2017-01-01
This volume contains selected papers submitted to the 15th Annual International Conference of the Bulgarian Comparative Education Society (BCES), held in June 2017 in Borovets, Bulgaria, and papers submitted to the 5th International Partner Conference of the International Research Centre (IRC) "Scientific Cooperation," Rostov-on-Don,…
Apparatus and Methods for Fluid Storage and Delivery
NASA Technical Reports Server (NTRS)
Parazynski, Scott E. (Inventor); Bue, Grant C. (Inventor); Urban, Kase C. (Inventor); Schaefbauer, Mark E. (Inventor)
2014-01-01
An apparatus and method for storing and delivering fluid to a person comprises, in at least one specific embodiment, a fluid reservoir having an internal volume therein with an opening disposed through a first wall or a second wall of the fluid reservoir and located toward a first end of the fluid reservoir. A first portion of a tube can be exterior to the fluid reservoir and a second portion of the tube can be disposed through the opening and within the internal volume. At least one insulation layer can be disposed about the exterior of the first wall of the fluid reservoir. The second wall of the fluid reservoir can be configured for transferring heat from or to the internal volume or from the person. At least one baffle is disposed within the internal volume and connected to the first wall and the second wall of the fluid reservoir.
Ice-volume-forced erosion of the Chinese Loess Plateau global Quaternary stratotype site.
Stevens, T; Buylaert, J-P; Thiel, C; Újvári, G; Yi, S; Murray, A S; Frechen, M; Lu, H
2018-03-07
The International Commission on Stratigraphy (ICS) utilises benchmark chronostratigraphies to divide geologic time. The reliability of these records is fundamental to understand past global change. Here we use the most detailed luminescence dating age model yet published to show that the ICS chronology for the Quaternary terrestrial type section at Jingbian, desert marginal Chinese Loess Plateau, is inaccurate. There are large hiatuses and depositional changes expressed across a dynamic gully landform at the site, which demonstrates rapid environmental shifts at the East Asian desert margin. We propose a new independent age model and reconstruct monsoon climate and desert expansion/contraction for the last ~250 ka. Our record demonstrates the dominant influence of ice volume on desert expansion, dust dynamics and sediment preservation, and further shows that East Asian Summer Monsoon (EASM) variation closely matches that of ice volume, but lags insolation by ~5 ka. These observations show that the EASM at the monsoon margin does not respond directly to precessional forcing.
Clasen, Stephan; Schmidt, Diethard; Boss, Andreas; Dietz, Klaus; Kröber, Stefan M; Claussen, Claus D; Pereira, Philippe L
2006-03-01
To evaluate the size and geometry of thermally induced coagulation by using multipolar radiofrequency (RF) ablation and to determine a mathematic model to predict coagulation volume. Multipolar RF ablations (n = 80) were performed in ex vivo bovine livers by using three internally cooled bipolar applicators with two electrodes on the same shaft. Applicators were placed in a triangular array (spacing, 2-5 cm) and were activated in multipolar mode (power output, 75-225 W). The size and geometry of the coagulation zone, together with ablation time, were assessed. Mathematic functions were fitted, and the goodness of fit was assessed by using r(2). Coagulation volume, short-axis diameter, and ablation time were dependent on power output and applicator distance. The maximum zone of coagulation (volume, 324 cm(3); short-axis diameter, 8.4 cm; ablation time, 193 min) was induced with a power output of 75 W at an applicator distance of 5 cm. Coagulation volume and ablation time decreased as power output increased. Power outputs of 100-125 W at applicator distances of 2-4 cm led to a reasonable compromise between coagulation volume and ablation time. At 2 cm (100 W), coagulation volume, short-axis diameter, and ablation time were 66 cm(3), 4.5 cm, and 19 min, respectively; at 3 cm (100 W), 90 cm(3), 5.2 cm, and 22 min, respectively; at 4 cm (100 W), 132 cm(3), 6.1 cm, and 27 min, respectively; at 2 cm (125 W), 56 cm(3), 4.2 cm, and 9 min, respectively; at 3 cm (125 W), 73 cm(3), 4.9 cm, and 12 min, respectively; and at 4 cm (125 W), 103 cm(3), 5.5 cm, and 16 min, respectively. At applicator distances of 4 cm (>125 W) and 5 cm (>100 W), the zones of coagulation were not confluent. Coagulation volume (r(2) = 0.80) and RF ablation time (r(2) = 0.93) were determined by using the mathematic model. Multipolar RF ablation with three bipolar applicators may produce large volumes of confluent coagulation ex vivo. A compromise is necessary between prolonged RF ablations at lower power outputs, which produce larger volumes of coagulation, and faster RF ablations at higher power outputs, which produce smaller volumes of coagulation. Copyright RSNA, 2006.
Systems and methods for separating a multiphase fluid
NASA Technical Reports Server (NTRS)
Weislogel, Mark M. (Inventor); Thomas, Evan A. (Inventor); Graf, John C. (Inventor)
2011-01-01
Apparatus and methods for separating a fluid are provided. The apparatus can include a separator and a collector having an internal volume defined at least in part by one or more surfaces narrowing toward a bottom portion of the volume. The separator can include an exit port oriented toward the bottom portion of the volume. The internal volume can receive a fluid expelled from the separator into a flow path in the collector and the flow path can include at least two directional transitions within the collector.
Characterizing International Travel Behavior from Geotagged Photos: A Case Study of Flickr
Yuan, Yihong; Medel, Monica
2016-01-01
Recent advances in multimedia and mobile technologies have facilitated large volumes of travel photos to be created and shared online. Although previous studies have utilized geotagged photos to model travel patterns at individual locations, there is limited research on how these datasets can model international travel behavior and inter-country travel flows—a crucial indicator to quantify the interactions between countries in tourism economics. Realizing the necessity to investigate the potential of geotagged photos in tourism geography, this research investigates international travel patterns from two perspectives: 1) We apply a series of indicators (radius of gyration (ROG), number of countries visited, and entropy) to measure the descriptive characteristics of international travel in different countries; 2) By constructing a gravity model of trade, we investigate how distance decay influences the magnitude of international travel flow between geographic entities, and whether (or how much) the popularity of a given destination (defined as the percentage of tourist income in national gross domestic product (GDP)) affects travel choices in different countries. The results provide valuable input to various commercial applications such as individual travel planning and destination suggestions. PMID:27159195
Characterizing International Travel Behavior from Geotagged Photos: A Case Study of Flickr.
Yuan, Yihong; Medel, Monica
2016-01-01
Recent advances in multimedia and mobile technologies have facilitated large volumes of travel photos to be created and shared online. Although previous studies have utilized geotagged photos to model travel patterns at individual locations, there is limited research on how these datasets can model international travel behavior and inter-country travel flows-a crucial indicator to quantify the interactions between countries in tourism economics. Realizing the necessity to investigate the potential of geotagged photos in tourism geography, this research investigates international travel patterns from two perspectives: 1) We apply a series of indicators (radius of gyration (ROG), number of countries visited, and entropy) to measure the descriptive characteristics of international travel in different countries; 2) By constructing a gravity model of trade, we investigate how distance decay influences the magnitude of international travel flow between geographic entities, and whether (or how much) the popularity of a given destination (defined as the percentage of tourist income in national gross domestic product (GDP)) affects travel choices in different countries. The results provide valuable input to various commercial applications such as individual travel planning and destination suggestions.
Water quality management library. 2. edition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eckenfelder, W.W.; Malina, J.F.; Patterson, J.W.
1998-12-31
A series of ten books offered in conjunction with Water Quality International, the Biennial Conference and Exposition of the International Association on Water Pollution Research and Control (IAWPRC). Volume 1, Activated Sludge Process, Design and Control, 2nd edition, 1998: Volume 2, Upgrading Wastewater Treatment Plants, 2nd edition, 1998: Volume 3, Toxicity Reduction, 2nd edition, 1998: Volume 4, Municipal Sewage Sludge Management, 2nd edition, 1998: Volume 5, Design and Retrofit of Wastewater Treatment Plants for Biological Nutrient Removal, 1st edition, 1992: Volume 6, Dynamics and Control of the Activated Sludge Process, 2nd edition, 1998: Volume 7: Design of Anaerobic Processes formore » the Treatment of Industrial and Municipal Wastes, 1st edition, 1992: Volume 8, Groundwater Remediation, 1st edition, 1992: Volume 9, Nonpoint Pollution and Urban Stormwater Management, 1st edition, 1995: Volume 10, Wastewater Reclamation and Reuse, 1st edition, 1998.« less
ERIC Educational Resources Information Center
McConnell, Grant D., Ed.; Gendron, Jean-Denis, Ed.
The third volume in a series of atlases of language vitality covers 13 countries of West Africa (Benin, Burkina Faso, Ivory Coast, Gambia, Ghana, Guinea, Guinea-Bissau, Liberia, Mali, Mauritania, Senegal, Sierra Leone, Togo) and 59 major languages. The atlas consists of four main parts. The first offers comparative data, in bar graph and tabular…
ERIC Educational Resources Information Center
Novotna, Jarmila, Ed.; Moraova, Hana, Ed.; Kratka, Magdalena, Ed.; Stehlikova, Nad'a, Ed.
2006-01-01
This document contains the fourth volume of the proceedings of the 30th Conference of the International Group for the Psychology of Mathematics Education. Conference presentations are centered around the theme "Mathematics at the Centre." This volume features 59 research reports by presenters with last names beginning between Kun and…
ERIC Educational Resources Information Center
Neurath, Otto; And Others
The monographs published from 1938 through 1970 under the general title of the International Encyclopedia of Unified Science are now published in two volumes (see also SE 012 543). The monographs included in this volume, and the philosophers who wrote them, are listed below. Foundations of the Social Sciences (Neurath); The Structure of Scientific…
ERIC Educational Resources Information Center
Novotna, Jarmila, Ed.; Moraova, Hana, Ed.; Kratka, Magdalena, Ed.; Stehlikova, Nad'a, Ed.
2006-01-01
This document contains the second volume of the proceedings of the 30th Annual Conference of the International Group for the Psychology of Mathematics Education. Conference presentations are centered around the theme "Mathematics at the Centre." This volume features 60 research reports by presenters with last names beginning between Abr…
ERIC Educational Resources Information Center
Fraser, Renee White; Shani, Hadasa
Intended as a companion piece to volume 2 in the Method Series, Environmental Health Planning (CE 024 230), this second of six volumes in the International Health Planning Reference Series is a combined literature review and annotated bibliography dealing with environmental factors in health planning for developing countries. The review identifies…
ERIC Educational Resources Information Center
Chick, Helen L., Ed.; Vincent, Jill L., Ed.
2005-01-01
The first volume of the 29th annual conference of the International Group for the Psychology of Mathematics Education contains plenary lecture and research forum papers as listed below. Short oral communications papers, poster presentations, brief summaries of discussion groups, and working sessions are also included in the volume. The plenary…
ERIC Educational Resources Information Center
Hoines, Marit Johnsen, Ed.;
2004-01-01
This document contains the second volume of the proceedings of the 28th annual conference of the International Group for the Psychology of Mathematics Education. Conference presentations are centered around the theme "Inclusion and Diversity". This volume features 65 research report papers: (1) Constructing Meanings and Utilities within Algebraic…
ERIC Educational Resources Information Center
Chick, Helen L., Ed.; Vincent, Jill L., Ed.
2005-01-01
This document contains the second volume of the proceedings of the 29th Conference of the International Group for the Psychology of Mathematics Education. Conference papers are centered around the theme of "Learners and Learning Environments." This volume features 43 research reports by presenters with last names beginning between Adl…
ERIC Educational Resources Information Center
Kelleher, Ann
The case studies presented in this volume offer comparative examples of undergraduate international education innovations in a wide variety of categories: curriculum, study abroad, community outreach, faculty development, and international students. The studies were conducted in the mid-1990s, and programs had to meet several criteria: they had to…
Ceres’ impact craters: probes of near-surface internal structure and composition
NASA Astrophysics Data System (ADS)
Bland, Michael T.; Raymond, Carol; Park, Ryan; Schenk, Paul; McCord, Tom; Reddy, Vishnu; King, Scott; Sykes, Mark; Russell, Chris
2015-11-01
Dawn Framing Camera images of Ceres have revealed the existence of a heavily cratered surface. Shape models derived from these images indicate that most (though not all) large craters are quite deep: up to 6 km for craters larger than 100 km in diameter. The retention of deep craters is not consistent with a simple differentiated internal structure consisting of an outer layer composed solely of pure water ice (covered with a rocky lag) overlying a rocky core. Here we use finite element simulations to show that, for Ceres’ relatively warm surface temperatures, the timescale required to completely flatten a crater 60-km in diameter (or greater) is less than 100 Myr, assuming a relatively pure outer ice layer (for ice grain sizes ≤ 1 cm). Preserving substantial topography requires that the viscosity of Ceres’ outer-most layer (25-50 km thick) is substantially greater than that of pure water ice. A factor of ten increase in viscosity can be achieved by assuming the layer is a 50/50 ice-rock mixture by volume; however, our simulations show that such an increase is insufficient to prevent substantial relaxation over timescales of 1 Gyr. Only particulate volume fractions greater than 50% provide an increase in viscosity sufficient to prevent large-scale, rapid relaxation. Such volume fractions suggest an outer layer composed of frozen soil/regolith (i.e., more rock than ice by volume), a very salt-rich layer, or both. Notably, while most basins appear quite deep, a few relatively shallow basins have been observed (e.g., Coniraya), suggesting that relaxation may be occurring over very long timescales (e.g., 4 Ga), that Ceres’ interior is compositionally and spatial heterogeneous, and/or that temporal evolution of the interior structure and composition has occurred. If these shallow basins are in fact the result of relaxation, it places an upper limit on the viscosity of Ceres’ outer-most interior layer, implying at least some low-viscosity material is present and likely eliminating the possibility of a purely rocky (homogeneous, low density, high porosity) interior.
Analysis of phases in the structure determination of an icosahedral virus.
Plevka, Pavel; Kaufmann, Bärbel; Rossmann, Michael G
2011-06-01
The constraints imposed on structure-factor phases by noncrystallographic symmetry (NCS) allow phase improvement, phase extension to higher resolution and hence ab initio phase determination. The more numerous the NCS redundancy and the greater the volume used for solvent flattening, the greater the power for phase determination. In a case analyzed here the icosahedral NCS phasing appeared to have broken down, although later successful phase extension was possible when the envelope around the NCS region was tightened. The phases from the failed phase-determination attempt fell into four classes, all of which satisfied the NCS constraints. These four classes corresponded to the correct solution, opposite enantiomorph, Babinet inversion and opposite enantiomorph with Babinet inversion. These incorrect solutions can be seeded from structure factors belonging to reciprocal-space volumes that lie close to icosahedral NCS axes where the structure amplitudes tend to be large and the phases tend to be 0 or π. Furthermore, the false solutions can spread more easily if there are large errors in defining the envelope designating the region in which NCS averaging is performed. © 2011 International Union of Crystallography
Coupled Finite Volume and Finite Element Method Analysis of a Complex Large-Span Roof Structure
NASA Astrophysics Data System (ADS)
Szafran, J.; Juszczyk, K.; Kamiński, M.
2017-12-01
The main goal of this paper is to present coupled Computational Fluid Dynamics and structural analysis for the precise determination of wind impact on internal forces and deformations of structural elements of a longspan roof structure. The Finite Volume Method (FVM) serves for a solution of the fluid flow problem to model the air flow around the structure, whose results are applied in turn as the boundary tractions in the Finite Element Method problem structural solution for the linear elastostatics with small deformations. The first part is carried out with the use of ANSYS 15.0 computer system, whereas the FEM system Robot supports stress analysis in particular roof members. A comparison of the wind pressure distribution throughout the roof surface shows some differences with respect to that available in the engineering designing codes like Eurocode, which deserves separate further numerical studies. Coupling of these two separate numerical techniques appears to be promising in view of future computational models of stochastic nature in large scale structural systems due to the stochastic perturbation method.
International Photovoltaic Program Plan. Volume II. Appendices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Costello, D.; Koontz, R.; Posner, D.
1979-12-01
This second volume of a two-part report on the International Photovoltaic Program Plan contains appendices summarizing the results of analyses conducted in preparation of the plan. These analyses include compilations of relevant statutes and existing Federal programs; strategies designed to expand the use of photovoltaics abroad; information on the domestic photovoltaic plan and its impact on the proposed international plan; perspectives on foreign competition; industry views on the international photovoltaic market and ideas about how US government actions could affect this market; international financing issues; and information on issues affecting foreign policy and developing countries.
A guide to federal-aid programs, projects, and other uses of highway funds
DOT National Transportation Integrated Search
2000-07-01
This Guide, Volume 2 - Websites, is part of the International Guide to Highway Transportation Information, a multi-volume set of Guides that provide highway transportation information resources for domestic and international professionals. In this Vo...
On the effect of standard PFEM remeshing on volume conservation in free-surface fluid flow problems
NASA Astrophysics Data System (ADS)
Franci, Alessandro; Cremonesi, Massimiliano
2017-07-01
The aim of this work is to analyze the remeshing procedure used in the particle finite element method (PFEM) and to investigate how this operation may affect the numerical results. The PFEM remeshing algorithm combines the Delaunay triangulation and the Alpha Shape method to guarantee a good quality of the Lagrangian mesh also in large deformation processes. However, this strategy may lead to local variations of the topology that may cause an artificial change of the global volume. The issue of volume conservation is here studied in detail. An accurate description of all the situations that may induce a volume variation during the PFEM regeneration of the mesh is provided. Moreover, the crucial role of the parameter α used in the Alpha Shape method is highlighted and a range of values of α for which the differences between the numerical results are negligible, is found. Furthermore, it is shown that the variation of volume induced by the remeshing reduces by refining the mesh. This check of convergence is of paramount importance for the reliability of the PFEM. The study is carried out for 2D free-surface fluid dynamics problems, however the conclusions can be extended to 3D and to all those problems characterized by significant variations of internal and external boundaries.
ERIC Educational Resources Information Center
Willis, Jerry, Ed.; Price, Jerry D., Ed.; McNeil, Sara, Ed.; Robin, Bernard, Ed.; Willis, Dee Anna, Ed.
The 370 conference papers on information technology and teacher education are presented in two volumes. The 183 papers in the first volume include the following topics: use and evaluation of educational software; preservice and inservice training issues; multimedia portfolios; distance education; diversity and international perspectives; the…
ERIC Educational Resources Information Center
Meserole, Harrison T., Comp.
Volume 1 of the four-volume, international bibliography contains over 11,140 entries referring to books, Festschriften, analyzed collections, and articles which focus on General, English, American, medieval and neo-Latin, and Celtic literatures. A section of folklore is also included. The section on general literature includes: (1) aesthetics, (2)…
ERIC Educational Resources Information Center
Hoines, Marit Johnsen, Ed.;
2004-01-01
This document contains the fourth volume of the proceedings of the 28th annual conference of the International Group for the Psychology of Mathematics Education. Conference presentations are centered around the theme "Inclusion and Diversity". This volume features 64 research report papers: (1) Situated or Abstract: The Effect of Combining Context…
ERIC Educational Resources Information Center
Hoines, Marit Johnsen, Ed.;
2004-01-01
This document contains the first volume of the proceedings of the 28th Annual Conference of the International Group for the Psychology of Mathematics Education. Conference presentations are centered around the theme "Inclusion and Diversity". In total, 147 presentations centered around the vision of mathematics for all. This volume features eight…
ERIC Educational Resources Information Center
Novotna, Jarmila, Ed.; Moraova, Hana, Ed.; Kratka, Magdalena, Ed.; Stehlikova, Nad'a, Ed.
2006-01-01
This document contains the third volume of the proceedings of the 30th Conference of the International Group for the Psychology of Mathematics Education. Conference presentations are centered around the theme "Mathematics at the Centre." This volume features 60 research reports by presenters with last names beginning between Ead and Kou:…
ERIC Educational Resources Information Center
Novotna, Jarmila, Ed.; Moraova, Hana, Ed.; Kratka, Magdalena, Ed.; Stehlikova, Nad'a, Ed.
2006-01-01
This document contains the fifth volume of the proceedings of the 30th Conference of the International Group for the Psychology of Mathematics Education. Conference presentations are centered around the theme "Mathematics at the Centre." This volume features 59 research reports by presenters with last names beginning between Sac and Zaz:…
ERIC Educational Resources Information Center
Chick, Helen L., Ed.; Vincent, Jill L., Ed.
2005-01-01
This document is the fourth volume of the proceedings of the 29th Conference of the International Group for the Psychology of Mathematics Education. Conference papers are centered around the theme of "Learners and Learning Environments." This volume features 42 research reports by presenters with last names beginning between Mul and Wu:…
Nineteenth International Cosmic Ray Conference. SH Sessions, Volume 5
NASA Technical Reports Server (NTRS)
Jones, F. C. (Compiler)
1985-01-01
Papers submitted for presentation at the 19th International Cosmic Ray Conference are compiled. This volume contains papers addressing cosmic ray gradients in the heliosphere; siderial, diurnal, and long term modulations; geomagnetic and atmospheric effects; cosmogenic nuclides; solar neutrinos; and detection techniques.
Vikre, Peter G.; John, David A.; du Bray, Edward A.; Fleck, Robert J.
2015-09-25
Based on volcanic stratigraphy, geochronology, remnant paleosurfaces, and paleopotentiometric surfaces in mining districts and alteration zones, present landforms in the Bodie Hills volcanic field reflect incremental construction of stratovolcanoes and large- to small-volume flow-domes, magmatic inflation, and fault displacements. Landform evolution began with construction of the 15–13 Ma Masonic and 13–12 Ma Aurora volcanic centers in the northwestern and northeastern parts of the field, respectively. Smaller volcanoes erupted at ~11–10 Ma in, between, and south of these centers as erosional detritus accumulated north of the field in Fletcher Valley. Distally sourced, 9.7–9.3 Ma Eureka Valley Tuff filled drainages and depressions among older volcanoes and was partly covered by nearly synchronous eruptives during construction of four large 10–8 Ma volcanoes, in the southern part of the field. The lack of significant internal fault displacement, distribution of Eureka Valley Tuff, and elevation estimates derived from floras, suggest that the Bodie Hills volcanic field attained present elevations mostly through volcano construction and magmatic inflation, and that maximum paleoelevations (>8,500 ft) at the end of large volume eruptions at ~8 Ma are similar to present elevations.
NASA Astrophysics Data System (ADS)
Xiao, Wenjiao
2016-06-01
This monograph book represents an important volume summarizing the present geological knowledge and understanding of the geodynamic evolution of large parts of the Central Asian Orogenic Belt (CAOB) or Altaids, which is one of the largest orogenic collages on Earth. The CAOB, like other major accretionary orogens, is a complex assembly of ancient microcontinents, arc terranes, accretionary wedges, fragments of oceanic volcanic islands (sea-mounts), oceanic plateaus, ophiolites, and shelf sediments from passive continental margins. The CAOB has caused much international attention due to its complicated architecture and considerably continental growth. However, after many years of investigations, some fundamental problems still remain controversial, such as the rate and volume of crustal growth, the origin of continental fragments, the detailed mechanism of accretion and collision, the role of terrane rotations during the orogeny, and the age and composition of the lower crust in Central Asia.
Mendler, Edward Charles
2005-02-01
The volumetric efficiency and power of internal combustion engines is improved with an intake port having an intake nozzle, a venturi, and a surge chamber. The venturi is located almost halfway upstream the intake port between the intake valves and the intake plenum enabling the venturi throat diameter to be exceptionally small for providing an exceptionally high ram velocity and an exceptionally long and in turn high efficiency diffuser flowing into the surge chamber. The intake port includes an exceptionally large surge chamber volume for blow down of the intake air into the working cylinder of the engine.
1994-07-14
and H. Ohkawa 31.2. Experimental Study on Controlling Size-Distribution of Droplets by Multi- Spray, M. Higuchi, T. Shirakawa, H. Morikita, K. Hishida...receiving aperture shape may lead to a non -linearity of the calibration curve, especially For group A40, results are dispersed leading to non - for large...compared with the results of group A40. The experimental conditions of group S125 in Fig. 8 21.4.6. have been used with the exception that the receiv
Effect of Early Adversity and Childhood Internalizing Symptoms on Brain Structure in Young Men.
Jensen, Sarah K G; Dickie, Erin W; Schwartz, Deborah H; Evans, C John; Dumontheil, Iroise; Paus, Tomáš; Barker, Edward D
2015-10-01
Early adversity is an important risk factor that relates to internalizing symptoms and altered brain structure. To assess the direct effects of early adversity and child internalizing symptoms (ie, depression, anxiety) on cortical gray matter (GM) volume, as well as the extent to which early adversity associates with variation in cortical GM volume indirectly via increased levels of internalizing symptoms. A prospective investigation of associations between adversity within the first 6 years of life, internalizing symptoms during childhood and early adolescence, and altered brain structure in late adolescence (age, 18-21 years) was conducted in a community-based birth cohort in England (Avon Longitudinal Study of Parents and Children). Participants from the cohort included 494 mother-son pairs monitored since the mothers were pregnant (estimated date of delivery between April 1, 1991, and December 31, 1992). Data collection for the present study was conducted between April 1, 1991, and November 30, 2010; the neuroimaging data were collected between September 1, 2010, and November 30, 2012, and data analyses for the present study occurred between January 25, 2013, and February 15, 2015. Risk factors were adversity within the first 6 years of the child's life (including prenatal exposure) and the child's internalizing symptoms between age 7 and 13 years. Early childhood adversity. The main outcome was GM volume of cortical regions previously associated with major depression measured through T1-weighted magnetic resonance images collected in late adolescence. Among 494 young men included in this analysis, early adversity was directly associated with lower GM volumes in the anterior cingulate cortex (β = -.18; P = .01) and higher GM volume in the precuneus (β = .18; P = .009). Childhood internalizing symptoms were associated with lower GM volume in the right superior frontal gyrus (β = -.20; P = .002). Early adversity was also associated with higher levels of internalizing symptoms (β = .37; P < .001), which, in turn, were associated with lower superior frontal gyrus volume (ie, an indirect effect) (β = -.08; 95% CI, -0.14 to -0.01; P = .02). Adversity early in life was associated with higher levels of internalizing symptoms as well as with altered brain structure. Early adversity was related to variation in brain structure both directly and via increased levels of internalizing symptoms. These findings may suggest that some of the structural variation often attributed to depression might be associated with early adversity in addition to the effect of depression.
Dual membrane hollow fiber fuel cell and method of operating same
NASA Technical Reports Server (NTRS)
Ingham, J. D.; Lawson, D. D. (Inventor)
1978-01-01
A gaseous fuel cell is described which includes a pair of electrodes formed by open-ended, ion-exchange hollow fibers, each having a layer of metal catalyst deposited on the inner surface and large surface area current collectors such as braided metal mesh in contact with the metal catalyst layer. A fuel cell results when the electrodes are immersed in electrolytes and electrically connected. As hydrogen and oxygen flow through the bore of the fibers, oxidation and reduction reactions develop an electrical potential. Since the hollow fiber configuration provides large electrode area per unit volume and intimate contact between fuel and oxidizer at the interface, and due to the low internal resistance of the electrolyte, high power densities can be obtained.
The Strata-1 Regolith Dynamics Experiment: Class 1E Science on ISS
NASA Technical Reports Server (NTRS)
Fries, Marc; Graham, Lee; John, Kristen
2016-01-01
The Strata-1 experiment studies the evolution of small body regolith through long-duration exposure of simulant materials to the microgravity environment on the International Space Station (ISS). This study will record segregation and mechanical dynamics of regolith simulants in a microgravity and vibration environment similar to that experienced by regolith on small Solar System bodies. Strata-1 will help us understand regolith dynamics and will inform design and procedures for landing and setting anchors, safely sampling and moving material on asteroidal surfaces, processing large volumes of material for in situ resource utilization (ISRU) purposes, and, in general, predicting the behavior of large and small particles on disturbed asteroid surfaces. This experiment is providing new insights into small body surface evolution.
Biosecurity and Health Monitoring at the Zebrafish International Resource Center
Varga, Zoltán M.; Kent, Michael L.
2016-01-01
Abstract The Zebrafish International Resource Center (ZIRC) is a repository and distribution center for mutant, transgenic, and wild-type zebrafish. In recent years annual imports of new zebrafish lines to ZIRC have increased tremendously. In addition, after 15 years of research, we have identified some of the most virulent pathogens affecting zebrafish that should be avoided in large production facilities, such as ZIRC. Therefore, while importing a high volume of new lines we prioritize safeguarding the health of our in-house fish colony. Here, we describe the biosecurity and health-monitoring program implemented at ZIRC. This strategy was designed to prevent introduction of new zebrafish pathogens, minimize pathogens already present in the facility, and ensure a healthy zebrafish colony for in-house uses and shipment to customers. PMID:27031282
NASA Technical Reports Server (NTRS)
Mitchell, G. A.; Sanders, B. W.
1975-01-01
The throat of a Mach 2.5 inlet with a coldpipe termination was fitted with a stability-bypass system. System variations included several stability bypass entrance configurations. Poppet valves controlled the bypass airflow. The inlet stable airflow range achieved with each configuration was determined for both steady state conditions and internal pulse transients. Results are compared with those obtained without a stability bypass system. Transient results were also obtained for the inlet with a choke point at the diffuser exit and for the inlet with large and small stability bypass plenum volumes. Poppet valves at the stability bypass exit provided the inlet with a stable airflow range of 20 percent or greater at all static and transient conditions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beyer, Christopher; Rosenthal, Anja; Myhill, Robert
We have performed an experimental cross calibration of a suite of mineral equilibria within mantle rock bulk compositions that are commonly used in geobarometry to determine the equilibration depths of upper mantle assemblages. Multiple barometers were compared simultaneously in experimental runs, where the pressure was determined using in-situ measurements of the unit cell volumes of MgO, NaCl, Re and h-BN between 3.6 and 10.4 GPa, and 1250 and 1500 °C. The experiments were performed in a large volume press (LVPs) in combination with synchrotron X-ray diffraction. Noble metal capsules drilled with multiple sample chambers were loaded with a range ofmore » bulk compositions representative of peridotite, eclogite and pyroxenite lithologies. By this approach, we simultaneously calibrated the geobarometers applicable to different mantle lithologies under identical and well determined pressure and temperature conditions. We identified discrepancies between the calculated and experimental pressures for which we propose simple linear or constant correction factors to some of the previously published barometric equations. As a result, we establish internally-consistent cross-calibrations for a number of garnet-orthopyroxene, garnet-clinopyroxene, Ca-Tschermaks-in-clinopyroxene and majorite geobarometers.« less
Cohen, Ouri; Huang, Shuning; McMahon, Michael T; Rosen, Matthew S; Farrar, Christian T
2018-05-13
To develop a fast magnetic resonance fingerprinting (MRF) method for quantitative chemical exchange saturation transfer (CEST) imaging. We implemented a CEST-MRF method to quantify the chemical exchange rate and volume fraction of the N α -amine protons of L-arginine (L-Arg) phantoms and the amide and semi-solid exchangeable protons of in vivo rat brain tissue. L-Arg phantoms were made with different concentrations (25-100 mM) and pH (pH 4-6). The MRF acquisition schedule varied the saturation power randomly for 30 iterations (phantom: 0-6 μT; in vivo: 0-4 μT) with a total acquisition time of ≤2 min. The signal trajectories were pattern-matched to a large dictionary of signal trajectories simulated using the Bloch-McConnell equations for different combinations of exchange rate, exchangeable proton volume fraction, and water T 1 and T 2 relaxation times. The chemical exchange rates of the N α -amine protons of L-Arg were significantly (P < 0.0001) correlated with the rates measured with the quantitation of exchange using saturation power method. Similarly, the L-Arg concentrations determined using MRF were significantly (P < 0.0001) correlated with the known concentrations. The pH dependence of the exchange rate was well fit (R 2 = 0.9186) by a base catalyzed exchange model. The amide proton exchange rate measured in rat brain cortex (34.8 ± 11.7 Hz) was in good agreement with that measured previously with the water exchange spectroscopy method (28.6 ± 7.4 Hz). The semi-solid proton volume fraction was elevated in white (12.2 ± 1.7%) compared to gray (8.1 ± 1.1%) matter brain regions in agreement with previous magnetization transfer studies. CEST-MRF provides a method for fast, quantitative CEST imaging. © 2018 International Society for Magnetic Resonance in Medicine.
Kaucner, Christine; Stinear, Timothy
1998-01-01
We recently described a reverse transcription-PCR (RT-PCR) for detecting low numbers of viable Cryptosporidium parvum oocysts spiked into clarified environmental water concentrates. We have now modified the assay for direct analysis of primary sample concentrates with simultaneous detection of viable C. parvum oocysts, Giardia cysts, and a novel type of internal positive control (IPC). The IPC was designed to assess both efficiency of mRNA isolation and potential RT-PCR inhibition. Sensitivity testing showed that low numbers of organisms, in the range of a single viable cyst and oocyst, could be detected when spiked into 100-μl packed pellet volumes of concentrates from creek and river water samples. The RT-PCR was compared with an immunofluorescence (IF) assay by analyzing 29 nonspiked environmental water samples. Sample volumes of 20 to 1,500 liters were concentrated with a wound fiberglass cartridge filter. Frequency of detection for viable Giardia cysts increased from 24% by IF microscopy to 69% by RT-PCR. Viable C. parvum oocysts were detected only once by RT-PCR (3%) in contrast to detection of viable Cryptosporidium spp. in four samples by IF microscopy (14%), suggesting that Cryptosporidium species other than C. parvum were present in the water. This combination of the large-volume sampling method with RT-PCR represents a significant advance in terms of protozoan pathogen monitoring and in the wider application of PCR technology to this field of microbiology. PMID:9572946
ERIC Educational Resources Information Center
Speiser, Robert, Ed.; Maher, Carolyn A., Ed.; Walter, Charles N., Ed.
This book contains volume 1 of the proceedings of the 23rd annual meeting of the International Group for the Psychology of Mathematics Education (PME) held October, 2001 in Snowbird, Utah. Papers include: (1) "Opening the Dimensions of Mathematical Capability: The Development of Knowledge, Practice and Identity in Mathematics Classrooms"…
Role of Water in Urban Ecology
NASA Astrophysics Data System (ADS)
Grigg, Neil S.
1984-04-01
This volume is a report on a symposium on the role of water in urban ecology held in Amsterdam in August 1979. The second international environmental symposium of the Koninklijke Nederlandsche Heide Maatschappij (Royal Netherlands Land Development Society) was cosponsored by the International Association for Ecology (INTECOL) and Elsevier Scientific Publishing Company with proceedings published in a special edition of the journal Urban Ecology, volume 6, pp. 1-362, from which this volume is reprinted.
Lorenzoni, Fabio Cesar; Bonfante, Estevam A; Bonfante, Gerson; Martins, Leandro M; Witek, Lukasz; Silva, Nelson R F A
2013-08-01
This evaluation aimed to (1) validate micro-computed tomography (microCT) findings using scanning electron microscopy (SEM) imaging, and (2) quantify the volume of voids and the bonded surface area resulting from fiber-reinforced composite (FRC) dowel cementation technique using microCT scanning technology/3D reconstructing software. A fiberglass dowel was cemented in a condemned maxillary lateral incisor prior to its extraction. A microCT scan was performed of the extracted tooth creating a large volume of data in DICOM format. This set of images was imported to image-processing software to inspect the internal architecture of structures. The outer surface and the spatial relationship of dentin, FRC dowel, cement layer, and voids were reconstructed. Three-dimensional spatial architecture of structures and volumetric analysis revealed that 9.89% of the resin cement was composed of voids and that the bonded area between root dentin and cement was 60.63% larger than that between cement and FRC dowel. SEM imaging demonstrated the presence of voids similarly observed using microCT technology (aim 1). MicroCT technology was able to nondestructively measure the volume of voids within the cement layer and the bonded surface area at the root/cement/FRC interfaces (aim 2). The interfaces at the root dentin/cement/dowel represent a timely and relevant topic where several efforts have been conducted in the past few years to understand their inherent features. MicroCT technology combined with 3D reconstruction allows for not only inspecting the internal arrangement rendered by fiberglass adhesively bonded to root dentin, but also estimating the volume of voids and contacted bond area between the dentin and cement layer. © 2013 by the American College of Prosthodontists.
ERIC Educational Resources Information Center
McConnell, Grant D., Ed.; Gendron, Jean-Denis, Ed.
This International atlas of language vitality offers a cartography of language functions, based on a quantitative measure of the vitality of each language. It covers the constitutional languages of India, and offers maps, graphs, and data tables illustrating the vitality ratings of 14 languages by state, domain of usage (religion, schools, mass…
Nineteenth International Cosmic Ray Conference. HE Sessions, Volume 8
NASA Technical Reports Server (NTRS)
Jones, F. C. (Compiler)
1985-01-01
Papers submitted for presentation at the 19th International Cosmic Ray Conference are compiled. The present volume contains papers addressing high energy interactions and related phenomena. Specific topic areas include muons, neutrinos, magnetic monopoles, nucleon decay, searches for new particles, and acoustic and thermoluminescence detection techniques.
NASA Astrophysics Data System (ADS)
Oh, Jihun; Kang, Xin; Wilson, Emmanuel; Peters, Craig A.; Kane, Timothy D.; Shekhar, Raj
2014-03-01
In laparoscopic surgery, live video provides visualization of the exposed organ surfaces in the surgical field, but is unable to show internal structures beneath those surfaces. The laparoscopic ultrasound is often used to visualize the internal structures, but its use is limited to intermittent confirmation because of the need for an extra hand to maneuver the ultrasound probe. Other limitations of using ultrasound are the difficulty of interpretation and the need for an extra port. The size of the ultrasound transducer may also be too large for its usage in small children. In this paper, we report on an augmented reality (AR) visualization system that features continuous hands-free volumetric ultrasound scanning of the surgical anatomy and video imaging from a stereoscopic laparoscope. The acquisition of volumetric ultrasound image is realized by precisely controlling a back-and-forth movement of an ultrasound transducer mounted on a linear slider. Furthermore, the ultrasound volume is refreshed several times per minute. This scanner will sit outside of the body in the envisioned use scenario and could be even integrated into the operating table. An overlay of the maximum intensity projection (MIP) of ultrasound volume on the laparoscopic stereo video through geometric transformations features an AR visualization system particularly suitable for children, because ultrasound is radiation-free and provides higher-quality images in small patients. The proposed AR representation promises to be better than the AR representation using ultrasound slice data.
Murata, Kazuhisa; Hayashi, Ken; Nakamura, Kei-ichiro
2018-01-01
Purpose To reevaluate the effect of internal limiting membrane peeling during vitrectomy on the Müller cell damage, we examined the ultrastructure of the internal limiting membrane by using focused ion beam/scanning electron microscopy (FIB/SEM). Methods A total of 12 internal limiting membranes obtained during surgery in both the macular hole and the idiopathic epiretinal membrane groups were processed for observation by FIB/SEM. Three-dimensional structures of the internal limiting membrane were analyzed. Results The number of cell fragments in the macular hole group was 5.07 ± 1.03 per unit area of internal limiting membrane (100 μm2). The total volume of cell fragments was 3.54 ± 1.24 μm3/100 μm2. In contrast, the number of cell fragments in the epiretinal membrane group was 12.85 ± 3.45/100 μm2, and the total volume of cell fragments was 10.45 ± 2.77 μm3/100 μm2. Data for both values were significantly higher than those observed in the macular hole group (P = 0.0024 and P = 0.0022, respectively, Mann-Whitney U test). No statistical difference was found for the mean volume of the cell fragment between the two groups. Conclusions All of the internal limiting membrane examined in this study showed cell fragments on the retinal surface of the internal limiting membrane. As compared with macular hole, epiretinal membrane exhibited a higher number and total volume of cell fragments, indicating that internal limiting membrane peeling for epiretinal membrane might have a higher risk of causing inner retinal damage. Translational Relevance FIB/SEM was a useful tool for three-dimensional quantitative analysis of the internal limiting membrane. PMID:29423341
Ninteenth International Cosmic Ray Conference. SH Sessions, Volume 4
NASA Technical Reports Server (NTRS)
Jones, F. C. (Compiler)
1985-01-01
Papers submitted for presentation at the 19th International Cosmic Ray Conference are compiled. This volume covers solar and heliospheric phenomena, specifically, particle acceleration; cosmic ray compsotion, spectra, and anisotropy; propagation of solar and interplanetary energetic particles; solar-cycle modulation; and propagation of galactic particles in the heliosphere.
International board-foot volume tables for trees in the Susitna River Basin, Alaska.
Frederic R. Larson
1990-01-01
International 1/4-inch board-foot volume equations and tables were derived from fall, buck, and scale data for 374 trees at 78 locations in the Susitna River Basin, Alaska. Tree species included white and black spruce, paper birch, black cottonwood, and quaking aspen.
High velocity collisions of nanoparticles
NASA Astrophysics Data System (ADS)
Johnson, Donald F.; Mattson, William D.
2017-01-01
Nanoparticles (NPs) are a unique class of material with highly functionalizable surfaces and exciting applications. With a large surface-to-volume ratio and potentially high surface tension, shocked nanoparticles might display unique materials behavior. Using density functional theory, we have simulated high-velocity NP collisions under a variety of conditions. NPs composed of diamond-C, cubic-BN, and diamond-Si were considered with particle sizes up to 3.5 nm diameter. Additional simulations involved NPs that were destabilized by incorporating internal strain. The initial spherical NP structures were carved out of bulk crystals while the NPs with internal strain were constructed as a dense core (compressive strain) encompassed by a thin shell (tensile strain). Both on-axis and off-axis collisions were simulated at 10 km/s relative velocity. The amount of internal strain was artificially increased by creating a dense inner core with bond lengths compressed up to 8%. Collision dynamics, shock propagation, and fragmentation will be analyzed, but the simulation are ongoing and results are not finalized. The effect of material properties, internal strain, and collision velocity will be discussed.
Large-Scale Trade in Legally Protected Marine Mollusc Shells from Java and Bali, Indonesia
Nijman, Vincent; Spaan, Denise; Nekaris, K. Anne-Isola
2015-01-01
Background Tropical marine molluscs are traded globally. Larger species with slow life histories are under threat from over-exploitation. We report on the trade in protected marine mollusc shells in and from Java and Bali, Indonesia. Since 1987 twelve species of marine molluscs are protected under Indonesian law to shield them from overexploitation. Despite this protection they are traded openly in large volumes. Methodology/Principal Findings We collected data on species composition, origins, volumes and prices at two large open markets (2013), collected data from wholesale traders (2013), and compiled seizure data by the Indonesian authorities (2008–2013). All twelve protected species were observed in trade. Smaller species were traded for
NASA Astrophysics Data System (ADS)
Davidge, Lindsey; Ebinger, Cynthia; Ruiz, Mario; Tepp, Gabrielle; Amelung, Falk; Geist, Dennis; Coté, Dustin; Anzieta, Juan
2017-03-01
Basaltic shield volcanoes of the western Galápagos islands are among the most rapidly deforming volcanoes worldwide, but little was known of the internal structure and brittle deformation processes accompanying inflation and deflation cycles. A 15-station broadband seismic array was deployed on and surrounding Sierra Negra volcano, Galápagos from July 2009 through June 2011 to characterize seismic strain patterns during an inter-eruption inflation period and to evaluate single and layered magma chamber models for ocean island volcanoes. We compare precise earthquake locations determined from a 3D velocity model and from a double difference cluster method. Using first-motion of P-arrivals, we determine focal mechanisms for 8 of the largest earthquakes (ML ≤ 1.5) located within the array. Most of the 2382 earthquakes detected by the array occurred beneath the broad (∼9 km-wide) Sierra Negra caldera, at depths from surface to about 8 km below sea level. Although outside our array, frequent and larger magnitude (ML ≤ 3.4) earthquakes occurred at Alcedo and Fernandina volcano, and in a spatial cluster beneath the shallow marine platform between Fernandina and Sierra Negra volcanoes. The time-space relations and focal mechanism solutions from a 4-day long period of intense seismicity June 4-9, 2010 along the southeastern flank of Sierra Negra suggests that the upward-migrating earthquake swarm occurred during a small volume intrusion at depths 5-8 km subsurface, but there was no detectable signal in InSAR data to further constrain geometry and volume. Focal mechanisms of earthquakes beneath the steep intra-caldera faults and along the ring fault system are reverse and strike-slip. These new seismicity data integrated with tomographic, geodetic, and petrological models indicate a stratified magmatic plumbing system: a shallow sill beneath the large caldera that is supplied by magma from a large volume deeper feeding system. The large amplitude inter-eruption inflation of the shallow sill beneath the Sierra Negra caldera is accompanied by only very small magnitude earthquakes, although historical records indicate that larger magnitude earthquakes (Mw <6) occur during eruptions, trapdoor faulting episodes without eruptions, and large volume flank intrusions.
Disc size regulation in the brood cell building behavior of leaf-cutter bee, Megachile tsurugensis
NASA Astrophysics Data System (ADS)
Kim, Jong-Yoon
2007-12-01
The leaf-cutter bee, Megachile tsurugensis, builds a brood cell in a preexisting tunnel with leaf discs that she cuts in decreasing sizes and assembles them like a Russian matryoshka doll. By experimentally manipulating the brood cell, it was investigated how she regulates the size of leaf discs that fit in the brood cell’s internal volume. When the internal volume was artificially increased by removing a bulk of leaf discs, she decreased the leaf disc size, although increasing it would have made the leaf disc more fitting in the increased internal volume. As a reverse manipulation, when the internal volume was decreased by inserting a group of inner layers of preassembled leaf discs to a brood cell, she decreased the leaf disc size, so that the leaf disc could fit in the decreased internal volume. These results suggest that she uses at least two different mechanisms to regulate the disc size: the use of some internal memory about the degree of building work accomplished in the first and of sensory feedback of dimensional information at the construction site in the second manipulation, respectively. It was concluded that a stigmergic mechanism, an immediate sensory feedback from the brood cell changed by the building work, alone cannot explain the details of the bee’s behavior particularly with respect to her initial response to the first manipulation. For a more complete explanation of the behavior exhibited by the solitary bee, two additional behavioral elements, reinforcement of building activity and processing of dimensional information, were discussed along with stigmergy.
Disc size regulation in the brood cell building behavior of leaf-cutter bee, Megachile tsurugensis.
Kim, Jong-yoon
2007-12-01
The leaf-cutter bee, Megachile tsurugensis, builds a brood cell in a preexisting tunnel with leaf discs that she cuts in decreasing sizes and assembles them like a Russian matryoshka doll. By experimentally manipulating the brood cell, it was investigated how she regulates the size of leaf discs that fit in the brood cell's internal volume. When the internal volume was artificially increased by removing a bulk of leaf discs, she decreased the leaf disc size, although increasing it would have made the leaf disc more fitting in the increased internal volume. As a reverse manipulation, when the internal volume was decreased by inserting a group of inner layers of preassembled leaf discs to a brood cell, she decreased the leaf disc size, so that the leaf disc could fit in the decreased internal volume. These results suggest that she uses at least two different mechanisms to regulate the disc size: the use of some internal memory about the degree of building work accomplished in the first and of sensory feedback of dimensional information at the construction site in the second manipulation, respectively. It was concluded that a stigmergic mechanism, an immediate sensory feedback from the brood cell changed by the building work, alone cannot explain the details of the bee's behavior particularly with respect to her initial response to the first manipulation. For a more complete explanation of the behavior exhibited by the solitary bee, two additional behavioral elements, reinforcement of building activity and processing of dimensional information, were discussed along with stigmergy.
The JGOFS North Atlantic Bloom Experiment: An overview
NASA Technical Reports Server (NTRS)
Ducklow, Hugh W.
1992-01-01
The North Atlantic Bloom Experiment (NABE) of JGOFS presents a unique opportunity and challenge to the data management community because of the diversity and large size of biogeochemical data sets collected. NABE was a pilot study for JGOFS and has also served as a pilot study within the U.S. NODC for management and archiving of the data sets. Here I present an overview to some of the scientific results of NABE, which will be published as an Introduction to a special volume of NABE results in Deep-Sea Research later this year. An overview of NABE data management is given elsewhere in the present report. This is the first collection of papers from the Joint Global Ocean Flux Study (JGOFS). Formed as an international program in 1987, JGOFS has four principal elements: modelling and data management, multidisciplinary regional process studies, a global survey of biogeochemical properties and long-term time series observatories. In 1989-1990 JGOFS conducted a pilot process study of the spring phytoplankton bloom, the North Atlantic Bloom Experiment (NABE). JGOFS decided to conduct a large scale, internationally-coordinated pilot study in the North Atlantic because of its proximity to the founding nations of the project, the size and predictability of the bloom and its fundamental impact on ocean bio-geochemistry (Billett et al., 1983; Watson and Whitfield, 1985; Pfannkuche, 1992). In 1989, six research vessels from Canada, Germany, The Netherlands, the United Kingdom and the USA and over 200 scientists and students from more than a dozen nations participated in NABE. Some of their initial results are reported in this volume.
NST: Thermal Modeling for a Large Aperture Solar Telescope
NASA Astrophysics Data System (ADS)
Coulter, Roy
2011-05-01
Late in the 1990s the Dutch Open Telescope demonstrated that internal seeing in open, large aperture solar telescopes can be controlled by flushing air across the primary mirror and other telescope structures exposed to sunlight. In that system natural wind provides a uniform air temperature throughout the imaging volume, while efficiently sweeping heated air away from the optics and mechanical structure. Big Bear Solar Observatory's New Solar Telescope (NST) was designed to realize that same performance in an enclosed system by using both natural wind through the dome and forced air circulation around the primary mirror to provide the uniform air temperatures required within the telescope volume. The NST is housed in a conventional, ventilated dome with a circular opening, in place of the standard dome slit, that allows sunlight to fall only on an aperture stop and the primary mirror. The primary mirror is housed deep inside a cylindrical cell with only minimal openings in the side at the level of the mirror. To date, the forced air and cooling systems designed for the NST primary mirror have not been implemented, yet the telescope regularly produces solar images indicative of the absence of mirror seeing. Computational Fluid Dynamics (CFD) analysis of the NST primary mirror system along with measurements of air flows within the dome, around the telescope structure, and internal to the mirror cell are used to explain the origin of this seemingly incongruent result. The CFD analysis is also extended to hypothetical systems of various scales. We will discuss the results of these investigations.
Determination for regional differences of agriculture using satellite data
NASA Astrophysics Data System (ADS)
Saito, G.
2006-12-01
Remote Sensing Laboratory, Field Science Center, Graduate School of Agriculture Science, Tohoku University starts at April 2004. For studies and education at the laboratory we are now developing the system of remote sensing and GIS. Earth Remote Sensing Data Analysis Center (ERSDAC) made the Home Pages of Terra/ASTER Image Web Library 3 "The Major Airport of the World." http://www.Ersdac.or.jp/ASTERimage3/library_E.html. First, we check the Airport Data to use agricultural understanding for the world. Almost major airport is located in rural area and surrounded with agriculture field. To survey the agriculture field adjacent to the major airport has almost the same condition of human activities. The images are same size and display about 18km X 14km. We can easily understand field size and surrounding conditions. We study seven airports as follows, 1. Tokyo Narita Airport (NRT), Japan, 2. Taipei Chiang kai Shek International Airport (TPE), Taiwan, 3. Bangkok International Airport (BKK), Thailand, 4. Riyadh King Khalid International Airport (RUH), Saudi Arabia, 5. Charles de Gaulle Airport (CDG), Paris, France, 6. Vienna International Airport (VIE), Austria, 7. Denver International Airport (DEN), CO, USA. At the area of Tokyo Narita Airport, there are many golf courses, big urban area and small size of agricultural fields. At Taipei Airport area are almost same as Tokyo Narita Airport area and there are many ponds for irrigations. Bangkok Airport area also has golf courses and many ponds for irrigation water. Riyadh Airport area is quite different from others, and there are large bare soils and small agriculture fields with irrigation and circle shape. Paris Airport area and Vienna Airport area are almost agricultural fields and there are vegetated field and bare soil fields because of crop rotation. Denver Airport area consists of almost agriculture fields and each field size is very large. The advantages of ASTER data are as follows, 1. High-resolution and large swath, 2. Large wavelength and many bands, 3. High-revel of geographical location, 4. Stereo pair images, 5. High performance data searching system, 6. High speed data delivery system, 7. Cheap price, 8. Seven years observation and large volume archive. A kind of project "Determination of Local Characteristics at Global Agriculture Using Archive ASTER Data" was started at middle of November 2005. We establish data processing system and get some results. Paddy rice fields analysis was started at first, we analyze 1) the Shonai Plains in Japan, 2) the Yangtze River delta in Middle-East China, 3) Mekong Delta in South Vietnam, 4) North-east Thai Plaines, Thailand, 5) Sacrament Valley, California, USA. The results of this studies are as follows, 1) Using ASTER images, we can easily understand agricultural characteristics of each local area. 2) ASTER data are high accuracy for location, and the accuracy is suitable for global study without the fine topographical maps, 3) By five years observation of ASTER, there is huge numbers of ASTER scenes, but not enough volumes for cloud free data for seasonal analysis. It means that follow-on program of ASTER is necessary, 4) We need not only paddy field, but also all crop fields and all area, 5) The studies are necessary to international corroboration.
INTRODUCTION: The 8th International Conference on Vacuum Ultraviolet Radiation Physics
NASA Astrophysics Data System (ADS)
Nilsson, Per Olof; Hedin, Lars
1987-01-01
The VUV conferences series The international conferences on vacuum ultraviolet radiation physics started in 1962, and are now being held every third year. VUV-8 took place at Lund University, August 4-8, 1986. VUV-9 will be arranged at the University of Hawaii, USA, August 14-18, 1989, with Prof. C S Fadley as conference chairman. Chairman of the international advisory board for the period 1986-89 is Prof. L Hedin. The theme of the series can be summarized as experimental and theoretical progress in research fields utilizing the interaction of VUV radiation with matter. The topics cover broad areas within atomic and molecular physics, solid state physics and VUV instrumentation. The conferences emphasize interdisciplinary aspects. To these belong common experimental techniques as, e.g., synchrotron radiation instrumentation, and common theoretical foundations for the description of photon interactions with matter. The VUV-8 conference The VUV-8 conference in Lund was attended by 300 participants from 26 countries. An address list of the participants is given at the end of this volume. There were 33 invited papers given as plenary or key-note talks. As many as 229 posters were presented; 49 of them were also given orally. These numbers are typical for the VUV conferences, except for the number of posters, which was unusually large. In the conference planning the poster sessions were stressed, and particular care was taken to provide a good atmosphere at these sessions. Thus the posters were kept up during the whole conference, coffee was served in the hail with the posters and there were convenient places to sit down close to the posters. Considering the wide scope of the conference it was necessary to emphasize a limited number of topics of high current interest and importance. Thus besides traditional topics, several rapidly expanding fields were discussed in special sessions. At VUV-8 there were the following sessions. Theory of atoms and molecules photoabsorption and -ionization of atoms and molecules and related phenomena multiphoton and other dynamical processes plasma physics VUV lasers time resolved spectroscopy instrumentation for VUV radiation synchrotron radiation centres solid state spectroscopy dynamical processes involving localized levels fundamental aspects of photoemission spin-polarized photoemission inverse photoemission semiconductors organic materials adsorbates Proceedings of VUV-8 The present volume contains most of the invited papers (28 out of 33). Regarding the contributed papers, over 50 are now being published in regular issues of PHYSICA SCRIPTA. These papers will also appear in a reprint volume, PHYSICA SCRIPTA RS4, which soon will be available. Abstracts of invited and contributed papers appeared in three conference volumes as follows: Volume I: Atomic and molecular physics. Instrumentation. Volume II: Solid state physics. Volume III: Post deadline papers. These books have been registered in an international data base and can thus be cited as published documents. Copies may be received from the conference secretary.* Acknowledgements We would like to thank our sponsors, which are listed on the following page, the members of the international program committee, and all others who helped in the planning of the program. Above all we like to thank those who worked with the local organization. Due to their dedicated efforts the conference ran very smoothly with a pleasant atmosphere.
NASA Astrophysics Data System (ADS)
Klingbeil, Knut; Lemarié, Florian; Debreu, Laurent; Burchard, Hans
2018-05-01
The state of the art of the numerics of hydrostatic structured-grid coastal ocean models is reviewed here. First, some fundamental differences in the hydrodynamics of the coastal ocean, such as the large surface elevation variation compared to the mean water depth, are contrasted against large scale ocean dynamics. Then the hydrodynamic equations as they are used in coastal ocean models as well as in large scale ocean models are presented, including parameterisations for turbulent transports. As steps towards discretisation, coordinate transformations and spatial discretisations based on a finite-volume approach are discussed with focus on the specific requirements for coastal ocean models. As in large scale ocean models, splitting of internal and external modes is essential also for coastal ocean models, but specific care is needed when drying & flooding of intertidal flats is included. As one obvious characteristic of coastal ocean models, open boundaries occur and need to be treated in a way that correct model forcing from outside is transmitted to the model domain without reflecting waves from the inside. Here, also new developments in two-way nesting are presented. Single processes such as internal inertia-gravity waves, advection and turbulence closure models are discussed with focus on the coastal scales. Some overview on existing hydrostatic structured-grid coastal ocean models is given, including their extensions towards non-hydrostatic models. Finally, an outlook on future perspectives is made.
Single-dose volume regulation algorithm for a gas-compensated intrathecal infusion pump.
Nam, Kyoung Won; Kim, Kwang Gi; Sung, Mun Hyun; Choi, Seong Wook; Kim, Dae Hyun; Jo, Yung Ho
2011-01-01
The internal pressures of medication reservoirs of gas-compensated intrathecal medication infusion pumps decrease when medication is discharged, and these discharge-induced pressure drops can decrease the volume of medication discharged. To prevent these reductions, the volumes discharged must be adjusted to maintain the required dosage levels. In this study, the authors developed an automatic control algorithm for an intrathecal infusion pump developed by the Korean National Cancer Center that regulates single-dose volumes. The proposed algorithm estimates the amount of medication remaining and adjusts control parameters automatically to maintain single-dose volumes at predetermined levels. Experimental results demonstrated that the proposed algorithm can regulate mean single-dose volumes with a variation of <3% and estimate the remaining medication volume with an accuracy of >98%. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Neves, Ricardo Cardoso; Reichert, Heinrich
2015-01-01
Cycliophorans have a complex life cycle that involves several sexual and asexual stages. One of the sexual stages is the 40 μm-long dwarf male, which is among the smallest free-living metazoans. Although the dwarf male has a highly complex body plan, this minute organism is composed of a very low number of somatic cells (~50). The developmental processes that give rise to this unique phenotype are largely unknown. Here we use high resolution serial block face—scanning electron microscopy to analyze the anatomy and morphogenesis of three cycliophoran dwarf males at different developmental stages ranging from internal bud to mature male. The anatomical and morphological features of the mature dwarf male stage reported here largely correspond to those reported in earlier studies. Interestingly, the organs that typically characterize the anatomy of the mature dwarf male, e.g., muscles, brain, testis and glands, are already formed in the young male. However, there are striking differences between the mature male and young male stages at the level of cellular architecture. Thus, while the young male stage, like the internal bud stage, possesses approximately 200 nucleated cells, the mature male stage comprises only around 50 nucleated cells; muscle and epidermal cells of the mature male lack nuclei. Moreover, the total body volume of the mature male is only 63% of the body of the young male implying that the maturation of the young male into a mature male involves a marked reduction of internal body volume, mainly by massive nuclei loss. Our comparative analysis of these dwarf male specimens reveals unprecedented insight into the striking morphological and developmental differences that characterize these highly miniaturized male stages both at the level of body organization and at the level of cellular ultrastructure. PMID:25875482
Finazzi, Stefano; Garbero, Elena; Trussardi, Giampietro; Bertolini, Guido
2017-05-01
Coupled plasma filtration and adsorption (CPFA) is an extracorporeal blood purification technique proposed for the treatment of septic-shock. By removing pro- and anti-inflammatory mediators from plasma, CPFA is supposed to have a therapeutic effect on the abnormal inflammatory response seen in this condition. Recently, blood predilution with citrate solution has been adopted to prevent clotting in the CPFA circuit-one of the main problems of the technique. Taking into account the patient's hematocrit, we worked out a formula for the volume of plasma effectively treated by CPFA after predilution. Neglecting this effect, as is commonly done, introduces significant distortions in the estimation of the volume, possibly causing under-treatment. The distortion is stronger when the hematocrit and the predilution fraction are large and weaker when both values shrink. By correctly indicating the daily dose of plasma adsorption received by patients, this formula is essential for assessing the therapeutic efficacy of CPFA and, subsequently, establishing its optimal doses. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
1991 SOLAR WORLD CONGRESS - VOLUME 1, PART I
The four-volume proceedings document the 1991 Solar World Congress (the biennial congress of the International Solar Energy Society) in Denver, CO, August 19-23, 1991. Volume 1 is dedicated to solar electricity, biofuels, and renewable resources. Volume 2 contains papers on activ...
Internal Flow Analysis of Large L/D Solid Rocket Motors
NASA Technical Reports Server (NTRS)
Laubacher, Brian A.
2000-01-01
Traditionally, Solid Rocket Motor (SRM) internal ballistic performance has been analyzed and predicted with either zero-dimensional (volume filling) codes or one-dimensional ballistics codes. One dimensional simulation of SRM performance is only necessary for ignition modeling, or for motors that have large length to port diameter ratios which exhibit an axial "pressure drop" during the early burn times. This type of prediction works quite well for many types of motors, however, when motor aspect ratios get large, and port to throat ratios get closer to one, two dimensional effects can become significant. The initial propellant grain configuration for the Space Shuttle Reusable Solid Rocket Motor (RSRM) was analyzed with 2-D, steady, axi-symmetric computational fluid dynamics (CFD). The results of the CFD analysis show that the steady-state performance prediction at the initial burn geometry, in general, agrees well with 1-D transient prediction results at an early time, however, significant features of the 2-D flow are captured with the CFD results that would otherwise go unnoticed. Capturing these subtle differences gives a greater confidence to modeling accuracy, and additional insight with which to model secondary internal flow effects like erosive burning. Detailed analysis of the 2-D flowfield has led to the discovery of its hidden 1-D isentropic behavior, and provided the means for a thorough and simplified understanding of internal solid rocket motor flow. Performance parameters such as nozzle stagnation pressure, static pressure drop, characteristic velocity, thrust and specific impulse are discussed in detail and compared for different modeling and prediction methods. The predicted performance using both the 1-D codes and the CFD results are compared with measured data obtained from static tests of the RSRM. The differences and limitations of predictions using ID and 2-D flow fields are discussed and some suggestions for the design of large L/D motors and more critically, motors with port to throat ratios near one, are covered.
NASA Astrophysics Data System (ADS)
Mutch, W. Alan C.
2005-05-01
Life support with a mechanical ventilator is used to manage patients with a variety of lung diseases including acute respiratory distress syndrome (ARDS). Recently, management of ARDS has concentrated on ventilating at lower airway pressure using lower tidal volume. A large international study demonstrated a 22% reduction in mortality with the low tidal volume approach. The potential advantages of adding physiologic noise with fractal characteristics to the respiratory rate and tidal volume as delivered by a mechanical ventilator are discussed. A so-called biologically variable ventilator (BVV), incorporating such noise, has been developed. Here we show that the benefits of noisy ventilation - at lower tidal volumes - can be deduced from a simple probabilistic result known as Jensen"s Inequality. Using the local convexity of the pressure-volume relationship in the lung we demonstrate that the addition of noise results in higher mean tidal volume or lower mean airway pressure. The consequence is enhanced gas exchange or less stress on the lungs, both clinically desirable. Jensen"s Inequality has important considerations in engineering, information theory and thermodynamics. Here is an example of the concept applied to medicine that may have important considerations for the clinical management of critically ill patients. Life support devices, such as mechanical ventilators, are of vital use in critical care units and operating rooms. These devices usually have monotonous output. Improving mechanical ventilators and other life support devices may be as simple as adding noise to their output signals.
Transient flows in active porous media
NASA Astrophysics Data System (ADS)
Kosmidis, Lefteris I.; Jensen, Kaare H.
2017-06-01
Stimuli-responsive materials that modify their shape in response to changes in environmental conditions—such as solute concentration, temperature, pH, and stress—are widespread in nature and technology. Applications include micro- and nanoporous materials used in filtration and flow control. The physiochemical mechanisms that induce internal volume modifications have been widely studied. The coupling between induced volume changes and solute transport through porous materials, however, is not well understood. Here, we consider advective and diffusive transport through a small channel linking two large reservoirs. A section of stimulus-responsive material regulates the channel permeability, which is a function of the local solute concentration. We derive an exact solution to the coupled transport problem and demonstrate the existence of a flow regime in which the steady state is reached via a damped oscillation around the equilibrium concentration value. Finally, the feasibility of an experimental observation of the phenomena is discussed.
ERIC Educational Resources Information Center
Nakahara, Tadao, Ed.; Koyama, Masataka, Ed.
The first volume of the 24th annual conference of the International Group for the Psychology of Mathematics Education includes plenary addresses, plenary panel discussions, research forum, project groups, discussion groups, short oral communications, and poster presentations. (ASK)
International Perspectives on Education. BCES Conference Books, Volume 10
ERIC Educational Resources Information Center
Popov, Nikolay, Ed.; Wolhuter, Charl, Ed.; Leutwyler, Bruno, Ed.; Hilton, Gillian, Ed.; Ogunleye, James, Ed.; Almeida, Patrícia Albergaria, Ed.
2012-01-01
This volume contains papers submitted to the 10th Annual Conference of the Bulgarian Comparative Education Society, held in Kyustendil, Bulgaria, 12-15 June 2012. The overall goal of the 10th BCES conference is to facilitate discussion of different perspectives on international education providing a forum for scientific debate and constructive…
ERIC Educational Resources Information Center
Baker, David, Ed.; Wiseman, Alex, Ed.
2006-01-01
This volume of International Perspectives on Education and Society explores how educational research from a comparative perspective has been instrumental in broadening and testing hypotheses from institutional theory. Institutional theory has also played an increasingly influential role in developing an understanding of education in society. This…
ERIC Educational Resources Information Center
Maryland Univ., College Park. Univ. Coll.
Seventy-four papers from a 1986 international conference on improving university teaching are presented. Topics include: student-teacher relationships, the pulse of the academic professional, improving teaching via techology, campus-corporate linkages, institutional changes and liberal learning, improving university teaching through evaluation,…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-27
.... In August 2010, the Center for Devices and Radiological Health (CDRH) published two documents in.... These documents are titled ``CDRH Preliminary Internal Evaluations--Volume I: 510(k) Working Group Preliminary Report and Recommendations'' and ``CDRH Preliminary Internal Evaluations--Volume II: Task Force on...
NASA Technical Reports Server (NTRS)
Edberg, Stephen J. (Editor)
1996-01-01
The International Halley Watch (IHW) was organized for the purpose of gathering and archiving the most complete record of the apparition of a comet, Halley's Comet (1982i = 1986 III = 1P/Halley), ever compiled. The redirection of the International Sun-Earth Explorer 3 (ISEE-3) spacecraft, subsequently renamed the International Cometary Explorer (ICE), toward Comet Giacobini- Zinner (1984e = 1985 XIII = 21P/Giacobini-Zinner) prompted the initiation of a formal watch on that comet. All the data collected on P/Giacobini-Zinner and P/Halley have been published on CD-ROM in the Comet Halley Archive. This document contains a printed version of the archive data, collected by amateur astronomers, on these two comets. Volume 1 contains the Comet Giacobini-Zinner data archive and Volume 2 contains the Comet Halley archive. Both volumes include information on how to read the data in both archives, as well as a history of both comet watches (including the organizing of the network of astronomers and lessons learned from that experience).
NASA Technical Reports Server (NTRS)
Edberg, Stephen J. (Editor)
1966-01-01
The International Halley Watch (IHW) was organized for the purpose of gathering and archiving the most complete record of the apparition of a comet, Halley's Comet (1982i = 1986 III = 1P/Halley), ever compiled. The redirection of the International Sun-Earth Explorer 3 (ISEE-3) spacecraft, subsequently renamed the International Cometary Explorer (ICE), toward Comet Giacobini-Zinner (1984e = 1985 XIII = 21P/Giacobini-Zinner) prompted the initiation of a formal watch on that comet. All the data collected on P/Giacobini-Zinner and P/Halley have been published on CD-ROM in the Comet Halley Archive. This document contains a printed version of the archive data, collected by amateur astronomers, on these two comets. Volume 1 contains the Comet Giacobini-Zinner data archive and Volume 2 contains the Comet Halley archive. Both volumes include information on how to read the data in both archives, as well as a history of both comet watches (including the organizing of the network of astronomers and lessons learned from that experience).
Gaskin, Cadeyrn J; Happell, Brenda
2013-02-01
Having sufficient power to detect effect sizes of an expected magnitude is a core consideration when designing studies in which inferential statistics will be used. The main aim of this study was to investigate the statistical power in studies published in the International Journal of Mental Health Nursing. From volumes 19 (2010) and 20 (2011) of the journal, studies were analysed for their power to detect small, medium, and large effect sizes, according to Cohen's guidelines. The power of the 23 studies included in this review to detect small, medium, and large effects was 0.34, 0.79, and 0.94, respectively. In 90% of papers, no adjustments for experiment-wise error were reported. With a median of nine inferential tests per paper, the mean experiment-wise error rate was 0.51. A priori power analyses were only reported in 17% of studies. Although effect sizes for correlations and regressions were routinely reported, effect sizes for other tests (χ(2)-tests, t-tests, ANOVA/MANOVA) were largely absent from the papers. All types of effect sizes were infrequently interpreted. Researchers are strongly encouraged to conduct power analyses when designing studies, and to avoid scattergun approaches to data analysis (i.e. undertaking large numbers of tests in the hope of finding 'significant' results). Because reviewing effect sizes is essential for determining the clinical significance of study findings, researchers would better serve the field of mental health nursing if they reported and interpreted effect sizes. © 2012 The Authors. International Journal of Mental Health Nursing © 2012 Australian College of Mental Health Nurses Inc.
Mondlane, Gracinda; Ureba, Ana; Gubanski, Michael; Lind, Pehr A; Siegbahn, Albert
2018-05-01
Gastric cancer (GC) radiotherapy involves irradiation of large tumour volumes located in the proximities of critical structures. The advantageous dose distributions produced by scanned-proton beams could reduce the irradiated volumes of the organs at risk (OARs). However, treatment-induced side-effects may still appear. The aim of this study was to estimate the normal tissue complication probability (NTCP) following proton therapy of GC, compared to photon radiotherapy. Eight GC patients, previously treated with volumetric-modulated arc therapy (VMAT), were retrospectively planned with scanned proton beams carried out with the single-field uniform-dose (SFUD) method. A beam-specific planning target volume was used for spot positioning and a clinical target volume (CTV) based robust optimisation was performed considering setup- and range-uncertainties. The dosimetric and NTCP values obtained with the VMAT and SFUD plans were compared. With SFUD, lower or similar dose-volume values were obtained for OARs, compared to VMAT. NTCP values of 0% were determined with the VMAT and SFUD plans for all OARs (p>0.05), except for the left kidney (p<0.05), for which lower toxicity was estimated with SFUD. The NTCP reduction, determined for the left kidney with SFUD, can be of clinical relevance for preserving renal function after radiotherapy of GC. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
NASA Technical Reports Server (NTRS)
Wieland, P. O.
1998-01-01
The International Space Station (ISS) incorporates elements designed and developed by an international consortium led by the United States (U.S.), and by Russia. For this cooperative effort to succeed, it is crucial that the designs and methods of design of the other partners are understood sufficiently to ensure compatibility. Environmental Control and Life Support (ECLS) is one system in which functions are performed independently on the Russian Segment (RS) and on the U.S./international segments. This document describes, in two volumes, the design and operation of the ECLS Systems (ECLSS) on board the ISS. This current volume, Volume 1, is divided into three chapters. Chapter 1 is a general overview of the ISS, describing the configuration, general requirements, and distribution of systems as related to the ECLSS, and includes discussion of the design philosophies of the partners and methods of verification of equipment. Chapter 2 describes the U.S. ECLSS and technologies in greater detail. Chapter 3 describes the ECLSS in the European Attached Pressurized Module (APM), Japanese Experiment Module (JEM), and Italian Mini-Pressurized Logistics Module (MPLM). Volume II describes the Russian ECLSS and technologies in greater detail. These documents present thorough, yet concise, descriptions of the ISS ECLSS.
Inacio, Maria C S; Graves, Stephen E; Pratt, Nicole L; Roughead, Elizabeth E; Nemes, Szilard
2017-08-01
The incidence of joint arthroplasty is increasing worldwide. International estimates of future demand for joint arthroplasty have used models that propose either an exponential future increase, despite obvious system constraints, or static increases, which do not account for past trends. Country-specific projection estimates that address limitations of past projections are necessary. In Australia, a high-income country with the 7th highest incidence of TKA and 15th highest incidence of THA of the Organization for Economic Cooperation and Development (OECD) countries, the volume of TKAs and THAs increased 198% between 1994 and 2014. To determine the projected incidence and volume of primary TKAs and THAs from 2014 to 2046 in the Australian population older than 40 years. Australian State and Territory Health Department data were used to identify TKAs and THAs performed between 1994 and 1995 and 2013 and 2014. The Australian Bureau of Statistics was the source of the population estimates for the same periods and population-projected estimates until 2046. The incidence rate (IR), 95% CI, and prediction interval (PI) of TKAs and THAs per 100,000 Australian citizens older than 40 years were calculated. Future IRs were estimated using a logistic model, and volume was calculated from projected IR and population. The logistic growth model assumes the existence of an upper limit of the TKA and THA incidences and a growth rate directly related to this incidence. At the beginning, when the observed incidence is much lower than the asymptote, the increase is exponential, but it decreases as it approaches the upper limit. A 66% increase in the IR of primary THAs between 2013 and 2046 is projected for Australia (2013: IR = 307 per 100,000, [95% CI, 262-329 per 100,000] compared with 2046: IR= 510 per 100,000, [95% PI, 98-567 per 100,000]), which translates to a 219% increase in the volume during this period. For TKAs the IR is expected to increase by 26% by 2046 (IR = 575 per 100,000; 95% PI, 402-717 per 100,000) compared with 2013 (IR = 437 per 100,000; 95% CI, 397-479 per 100,000) and the volume to increase by 142%. A large increase in the volume of arthroplasties is expected using a conservative projection model that accounts for past surgical trends and future population changes in Australia. These findings have international implications, as they show that using country- specific, conservative projection approaches, a substantial increase in the number of these procedures is expected. This increase in joint arthroplasty volume will require appropriate workforce planning, resource allocation, and budget planning so that demand can be met. Level II, economic and decision analysis.
Thermoregulation in larval aggregations of carrion-feeding blow flies (Diptera: Calliphoridae)
Slone, D.H.; Gruner, Susan V.
2007-01-01
The growth and development of carrion-feeding calliphorid (Diptera Calliphoridae) larvae, or maggots, is of great interest to forensic sciences, especially for estimation of a postmortem interval (PMI). The development rate of calliphorid larvae is influenced by the temperature of their immediate environment. Heat generation in larval feeding aggregations (=maggot masses) is a well-known phenomenon, but it has not been quantitatively described. Calculated development rates that do not include internally generated temperatures will result in overestimation of PMI. Over a period of 2.5 yr, 80 pig, Sus scrofa L., carcasses were placed out at study sites in north central Florida and northwestern Indiana. Once larval aggregations started to form, multiple internal and external temperatures, and weather observations were taken daily or every few days between 1400 and 1800 hours until pupation of the larvae. Volume of each aggregation was determined by measuring surface area and average depth. Live and preserved samples of larvae were taken for species identification. The four most common species collected were Lucilia coeruleiviridis (=Phaenicia) (Macquart) (77%), Cochliomyia macellaria (F.) (8.3%), Chrysomya rufifaces (Macquart) (7.7%), and Phormia regina (Meigen) (5.5%). Statistical analyses showed that 1) volume of a larval mass had a strong influence on its temperature, 2) internal temperatures of masses on the ground were influenced by soil temperature and mass volume, 3) internal temperatures of masses smaller than 20 cm3 were influenced by ambient air temperature and mass volume, and 4) masses larger than 20 cm3 on the carcass had strongly regulated internal temperatures determined only by the volume of the mass, with larger volumes associated with higher temperatures. Nonsignificant factors included presence of rain or clouds, shape of the aggregation, weight of the carcass, species composition of the aggregation, time since death, or season.
Quantitative assessment of whole-body tumor burden in adult patients with neurofibromatosis.
Plotkin, Scott R; Bredella, Miriam A; Cai, Wenli; Kassarjian, Ara; Harris, Gordon J; Esparza, Sonia; Merker, Vanessa L; Munn, Lance L; Muzikansky, Alona; Askenazi, Manor; Nguyen, Rosa; Wenzel, Ralph; Mautner, Victor F
2012-01-01
Patients with neurofibromatosis 1 (NF1), NF2, and schwannomatosis are at risk for multiple nerve sheath tumors and premature mortality. Traditional magnetic resonance imaging (MRI) has limited ability to assess disease burden accurately. The aim of this study was to establish an international cohort of patients with quantified whole-body internal tumor burden and to correlate tumor burden with clinical features of disease. We determined the number, volume, and distribution of internal nerve sheath tumors in patients using whole-body MRI (WBMRI) and three-dimensional computerized volumetry. We quantified the distribution of tumor volume across body regions and used unsupervised cluster analysis to group patients based on tumor distribution. We correlated the presence and volume of internal tumors with disease-related and demographic factors. WBMRI identified 1286 tumors in 145/247 patients (59%). Schwannomatosis patients had the highest prevalence of tumors (P = 0.03), but NF1 patients had the highest median tumor volume (P = 0.02). Tumor volume was unevenly distributed across body regions with overrepresentation of the head/neck and pelvis. Risk factors for internal nerve sheath tumors included decreasing numbers of café-au-lait macules in NF1 patients (P = 0.003) and history of skeletal abnormalities in NF2 patients (P = 0.09). Risk factors for higher tumor volume included female gender (P = 0.05) and increasing subcutaneous neurofibromas (P = 0.03) in NF1 patients, absence of cutaneous schwannomas in NF2 patients (P = 0.06), and increasing age in schwannomatosis patients (p = 0.10). WBMRI provides a comprehensive phenotype of neurofibromatosis patients, identifies distinct anatomic subgroups, and provides the basis for investigating molecular biomarkers that correlate with unique disease manifestations.
Quantitative Assessment of Whole-Body Tumor Burden in Adult Patients with Neurofibromatosis
Plotkin, Scott R.; Bredella, Miriam A.; Cai, Wenli; Kassarjian, Ara; Harris, Gordon J.; Esparza, Sonia; Merker, Vanessa L.; Munn, Lance L.; Muzikansky, Alona; Askenazi, Manor; Nguyen, Rosa; Wenzel, Ralph; Mautner, Victor F.
2012-01-01
Purpose Patients with neurofibromatosis 1 (NF1), NF2, and schwannomatosis are at risk for multiple nerve sheath tumors and premature mortality. Traditional magnetic resonance imaging (MRI) has limited ability to assess disease burden accurately. The aim of this study was to establish an international cohort of patients with quantified whole-body internal tumor burden and to correlate tumor burden with clinical features of disease. Methods We determined the number, volume, and distribution of internal nerve sheath tumors in patients using whole-body MRI (WBMRI) and three-dimensional computerized volumetry. We quantified the distribution of tumor volume across body regions and used unsupervised cluster analysis to group patients based on tumor distribution. We correlated the presence and volume of internal tumors with disease-related and demographic factors. Results WBMRI identified 1286 tumors in 145/247 patients (59%). Schwannomatosis patients had the highest prevalence of tumors (P = 0.03), but NF1 patients had the highest median tumor volume (P = 0.02). Tumor volume was unevenly distributed across body regions with overrepresentation of the head/neck and pelvis. Risk factors for internal nerve sheath tumors included decreasing numbers of café-au-lait macules in NF1 patients (P = 0.003) and history of skeletal abnormalities in NF2 patients (P = 0.09). Risk factors for higher tumor volume included female gender (P = 0.05) and increasing subcutaneous neurofibromas (P = 0.03) in NF1 patients, absence of cutaneous schwannomas in NF2 patients (P = 0.06), and increasing age in schwannomatosis patients (p = 0.10). Conclusion WBMRI provides a comprehensive phenotype of neurofibromatosis patients, identifies distinct anatomic subgroups, and provides the basis for investigating molecular biomarkers that correlate with unique disease manifestations. PMID:22558206
Eifler, Robert L; Lind, Judith; Falkenhagen, Dieter; Weber, Viktoria; Fischer, Michael B; Zeillinger, Robert
2011-03-01
The aim of this study was to determine the applicability of a sequential process using leukapheresis, elutriation, and fluorescence-activated cell sorting (FACS) to enrich and isolate circulating tumor cells from a large blood volume to allow further molecular analysis. Mononuclear cells were collected from 10 L of blood by leukapheresis, to which carboxyfluorescein succinimidyl ester prelabeled CaOV-3 tumor cells were spiked at a ratio of 26 to 10⁶ leukocytes. Elutriation separated the spiked leukapheresates primarily by cell size into distinct fractions, and leukocytes and tumor cells, characterized as carboxyfluorescein succinimidyl ester positive, EpCAM positive and CD45 negative events, were quantified by flow cytometry. Tumor cells were isolated from the last fraction using FACS or anti-EpCAM coupled immunomagnetic beads, and their recovery and purity determined by fluorescent microscopy and real-time PCR. Leukapheresis collected 13.5 x 10⁹ mononuclear cells with 87% efficiency. In total, 53 to 78% of spiked tumor cells were pre-enriched in the last elutriation fraction among 1.6 x 10⁹ monocytes. Flow cytometry predicted a circulating tumor cell purity of ~90% giving an enrichment of 100,000-fold following leukapheresis, elutriation, and FACS, where CaOV-3 cells were identified as EpCAM positive and CD45 negative events. FACS confirmed this purity. Alternatively, immunomagnetic bead adsorption recovered 10% of tumor cells with a median purity of 3.5%. This proof of concept study demonstrated that elutriation and FACS following leukapheresis are able to enrich and isolate tumor cells from a large blood volume for molecular characterization. Copyright © 2010 International Clinical Cytometry Society.
Low temperature probe for dynamic nuclear polarization and multiple-pulse solid-state NMR.
Cho, HyungJoon; Baugh, Jonathan; Ryan, Colm A; Cory, David G; Ramanathan, Chandrasekhar
2007-08-01
Here, we describe the design and performance characteristics of a low temperature probe for dynamic nuclear polarization (DNP) experiments, which is compatible with demanding multiple-pulse experiments. The competing goals of a high-Q microwave cavity to achieve large DNP enhancements and a high efficiency NMR circuit for multiple-pulse control lead to inevitable engineering tradeoffs. We have designed two probes-one with a single-resonance RF circuit and a horn-mirror cavity configuration for the microwaves and a second with a double-resonance RF circuit and a double-horn cavity configuration. The advantage of the design is that the sample is in vacuum, the RF circuits are locally tuned, and the microwave resonator has a large internal volume that is compatible with the use of RF and gradient coils.
Hemodiafiltration history, technology, and clinical results.
Ronco, Claudio; Cruz, Dinna
2007-07-01
Hemodiafiltration (HDF) is an extracorporeal renal-replacement technique using a highly permeable membrane, in which diffusion and convection are conveniently combined to enhance solute removal in a wide spectrum of molecular weights. In this modality, ultrafiltration exceeds the desired fluid loss in the patient, and replacement fluid must be administered to achieve the target fluid balance. Over the years, various HDF variants have emerged, including acetate-free biofiltration, high-volume HDF, internal HDF, paired-filtration dialysis, middilution HDF, double high-flux HDF, push-pull HDF, and online HDF. Recent technology has allowed online production of large volumes of microbiologically ultrapure fluid for reinfusion, greatly simplifying the practice of HDF. Several advantages of HDF over purely diffusive hemodialysis techniques have been described in the literature, including a greater clearance of urea, phosphate, beta(2)-microglobulin and other larger solutes, reduction in dialysis hypotension, and improved anemia management. Although randomized controlled trials have failed to show a survival benefit of HDF, recent data from large observational studies suggest a positive effect of HDF on survival. This article provides a brief review of the history of HDF, the various HDF techniques, and summary of their clinical effects.
Backe, Will J.; Ort, Christoph; Brewer, Alex J.; Field, Jennifer A.
2014-01-01
A new method was developed for the analysis of natural and synthetic androgenic steroids and their selected metabolites in aquatic environmental matrices using direct large-volume injection (LVI) high performance liquid chromatography (HPLC) tandem mass spectrometry (MS/MS). Method accuracy ranged from 88 to 108% for analytes with well-matched internal standards. Precision, quantified by relative standard deviation (RSD), was less than 12%. Detection limits for the method ranged from 1.2 to 360 ng/L. The method was demonstrated on a series of 1-hr composite wastewater influent samples collected over a day with the purpose of assessing temporal profiles of androgen loads in wastewater. Testosterone, androstenedione, boldenone, and nandrolone were detected in the sample series at concentrations up to 290 ng/L and loads up to 535 mg. Boldenone, a synthetic androgen, had a temporal profile that was strongly correlated to testosterone, a natural human androgen, suggesting its source may be endogenous. An analysis of the sample particulate fraction revealed detectable amounts of sorbed testosterone and androstenedione. Androstenedione sorbed to the particulate fraction accounted for an estimated five to seven percent of the total androstenedione mass. PMID:21391574
Backe, Will J; Ort, Christoph; Brewer, Alex J; Field, Jennifer A
2011-04-01
A new method was developed for the analysis of natural and synthetic androgenic steroids and their selected metabolites in aquatic environmental matrixes using direct large-volume injection (LVI) high-performance liquid chromatography (HPLC) tandem mass spectrometry (MS/MS). Method accuracy ranged from 87.6 to 108% for analytes with well-matched internal standards. Precision, quantified by relative standard deviation (RSD), was less than 12%. Detection limits for the method ranged from 1.2 to 360 ng/L. The method was demonstrated on a series of 1 h composite wastewater influent samples collected over a day with the purpose of assessing temporal profiles of androgen loads in wastewater. Testosterone, androstenedione, boldenone, and nandrolone were detected in the sample series at concentrations up to 290 ng/L and loads up to 535 mg/h. Boldenone, a synthetic androgen, had a temporal profile that was strongly correlated to testosterone, a natural human androgen, suggesting its source may be endogenous. An analysis of the sample particulate fraction revealed detectable amounts of sorbed testosterone and androstenedione. Androstenedione sorbed to the particulate fraction accounted for an estimated 5 to 7% of the total androstenedione mass.
Subregional volumes of the hippocampus in relation to cognitive function and risk of dementia.
Evans, Tavia E; Adams, Hieab H H; Licher, Silvan; Wolters, Frank J; van der Lugt, Aad; Ikram, M Kamran; O'Sullivan, Michael J; Vernooij, Meike W; Ikram, M Arfan
2018-05-18
Total hippocampal volume has been consistently linked to cognitive function and dementia. Yet, given its complex and parcellated internal structure, the role of subregions of the hippocampus in cognition and risk of dementia remains relatively underexplored. We studied subregions of the hippocampus in a large population-based cohort to further understand their role in cognitive impairment and dementia risk. We studied 5035 dementia- and stroke-free persons from the Rotterdam Study, aged over 45 years. All participants underwent magnetic resonance imaging (1.5 T) between 2005 and 2015. Automatic segmentation of the hippocampus and 12 of its subregions was performed using the FreeSurfer software (version 6.0). A cognitive test battery was performed, and participants were followed up for the development of dementia until 2015. Associations of hippocampal subregion volumes with cognition and incident dementia were examined using linear and Cox regression models, respectively. All analyses were adjusted for age, sex, education, and total hippocampal volume. Mean age was 64.3 years (SD 10.6) with 56% women. Smaller volumes of the hippocampal fimbria, presubiculum and subiculum showed the strongest associations with poor performance on several cognitive domains, including executive function but not memory. During a mean follow-up of 5.5 years, 76 persons developed dementia. Smaller subiculum volume was associated with risk of dementia adjusted for total volume (hazard ratio per SD decrease in volume: 1.75, 95% confidence interval 1.35; 2.26). In a community-dwelling non-demented population, we describe patterns of association between hippocampal subregions with cognition and risk of dementia. Specifically, the subiculum was associated with both poorer cognition and higher risk of dementia. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.
1992-03-06
convected at high speed ". Philosophical Transactions of the Royal Society A , Vol. 255, 1963, pp. 469-503. 16. DOWLING, A.P., FFOWCS WILLIAMS, J.E. and...atmosphere Af, 1 , M,2 convective Mach number of large scale turbulence structures on the high and low speed sides, respec- tively, of a two-dimensional...level of aerodynamic detuning (0 gust frequency 113 INTRODUCTION In the design of high performance gas turbine engines, acoustic analyses are a
DOE Office of Scientific and Technical Information (OSTI.GOV)
Acciarri, R.
2016-01-22
This document presents the Conceptual Design Report (CDR) put forward by an international neutrino community to pursue the Deep Underground Neutrino Experiment at the Long-Baseline Neutrino Facility (LBNF/DUNE), a groundbreaking science experiment for long-baseline neutrino oscillation studies and for neutrino astrophysics and nucleon decay searches. The DUNE far detector will be a very large modular liquid argon time-projection chamber (LArTPC) located deep underground, coupled to the LBNF multi-megawatt wide-band neutrino beam. DUNE will also have a high-resolution and high-precision near detector.
Note: An improved solenoid driver valve for miniature shock tubes.
Lynch, P T
2016-05-01
A solenoid driver valve has been built to improve the operating performance of diaphragmless shock tubes, which are used for high pressure, high temperature chemical kinetics, and fluid mechanics studies. For shock tube driver application, the most important characteristics are those of sealing, strength, and quality of the generated shock waves and repeatability of opening characteristics and therefore subsequent post-shock conditions. The main features of the new driver valve are a face o-ring sealing design of the valve, the large internal volume, and through inserts near the solenoid core: adjustable opening characteristics of the valve.
1981-05-01
be allocated to targets on the battlefield and in the rear area. The speaker describes the VECTOR I/NUCLEAR model, a combination of the UNICORN target...outlined. UNICORN is compatible with VECTOR 1 in level of detail. It is an expected value damage model and uses linear programming to optimize the...and a growing appreciation for the power of simulation in addressing large, complex problems, it was only a few short years before these games had
Data Integration and Analysis System (DIAS) Contributing to the Sustainable Development Goals (SDGs)
NASA Astrophysics Data System (ADS)
Koike, T.
2014-12-01
It has been said that scientists and experts usually use 80% of their research time for data management (DOE, 2002). Only 20% of research time is used for purely scientific activities. This ratio should be reversed by introducing computer science technology. To realize this goal, the Japanese government supported the development of a data system called "Data Integration and Analysis System (DIAS)," as one of the national key projects promoted by the Council for Science and Technology Policy (CSTP) from 2006 to 2010. A follow-up 5-year project is also ongoing. The essential aim for the DIAS was to create knowledge that would enable solutions to problems and generate socioeconomic benefits. DIAS mainly consists of four data components including data injection, management, integration, and interoperability. DIAS is now tackling a large increase in the diversity and volume of data from observing the Earth. Dictionaries have been developing an ontology system for technical and geographical terms, and a metadata design has been completed according to international standards. The volume of data stored has exponentially increased. Previously, almost all of the large-volume data came from satellites, but model outputs occupy the largest volume of our data storage nowadays. In collaboration with scientific and technological groups, DIAS can accelerate data archiving by including data loading, quality checking, metadata registration, and our system data-searching capability is being enriched. DIAS also enables us to perform integrated research and realize interdisciplinarity. Essentially, we are now working in the fields of climate, water resources, food, fisheries, and biodiversity by collaborating between different disciplines and trying to develop bases of contribution to Sustainable Development Goals (SDGs).
Gautheron, Vincent; Xie, Yu; Tisserand, Marie; Raoult, Hélène; Soize, Sébastien; Naggara, Olivier; Bourcier, Romain; Richard, Sébastien; Guillemin, Francis; Bracard, Serge; Oppenheim, Catherine
2018-03-01
Stroke patients with large diffusion-weighted imaging (DWI) volumes are often excluded from reperfusion because of reckoned futility. In those with DWI volume >70 mL, included in the THRACE trial (Mechanical Thrombectomy After Intravenous Alteplase Versus Alteplase Alone After Stroke), we report the associations between baseline parameters and outcome. We examined 304 patients with anterior circulation stroke and pretreatment magnetic resonance imaging. Variables were extracted from the THRACE database, and DWI volumes were measured semiautomatically. Among 53 patients with DWI volume >70 mL, 12 had favorable outcome (modified Rankin Scale score, ≤2) at 3 months; they had less coronary disease (0/12 versus 12/38; P =0.046) and less history of smoking (1/10 versus 12/31; P =0.013) than patients with modified Rankin Scale score >2. None of the 8 patients >75 years of age reached modified Rankin Scale score ≤2. Favorable outcome occurred in 12 of 37 M1-occluded patients but in 0 of 16 internal carotid-T/L-occluded patients ( P =0.010). Favorable outcome was more frequent (6/13) when DWI lesion was limited to the superficial middle cerebral artery territory than when it extended to the deep middle cerebral artery territory (6/40; P =0.050). Stroke patients with DWI lesion >70 mL may benefit from reperfusion therapy, especially those with isolated M1 occlusion or ischemia restricted to the superficial middle cerebral artery territory. The benefit of treatment seems questionable for patients with carotid occlusion or lesion extending to the deep middle cerebral artery territory. © 2018 American Heart Association, Inc.
Cook, John B.; Lin, Terri C.; Detsi, Eric; ...
2017-01-05
Tin metal is an attractive negative electrode material to replace graphite in Li-ion batteries due to its high energy density. However, tin undergoes a large volume change upon alloying with Li, which pulverizes the particles, and ultimately leads to short cycling lifetimes. Nevertheless, nanoporous materials have been shown to extend battery life well past what is observed in nonporous material. Despite the exciting potential of porous alloying anodes to significantly increase the energy density in Li-ion batteries, the fundamental physics of how nanoscale architectures accommodate the electrochemically induced volume changes are poorly understood. Here, operando transmission X-ray microscopy has beenmore » used to develop an understanding of the mechanisms that govern the enhanced cycling stability in nanoporous tin. We found that in comparison to dense tin, nanoporous tin undergoes a 6-fold smaller areal expansion after lithiation, as a result of the internal porosity and unique nanoscale architecture. The expansion is also more gradual in nanoporous tin compared to the dense material. The nanoscale resolution of the microscope used in this study is ~30 nm, which allowed us to directly observe the pore structure during lithiation and delithiation. We found that nanoporous tin remains porous during the first insertion and desinsertion cycle. This observation is key, as fully closed pores could lead to mechanical instability, electrolyte inaccessibility, and short lifetimes. Here, while tin was chosen for this study because of its high X-ray contrast, the results of this work should be general to other alloy-type systems, such as Si, that also suffer from volume change based cycling degradation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shih, Helen A.; Harisinghani, Mukesh; Zietman, Anthony L.
2005-11-15
Purpose: Toxicity from pelvic irradiation could be reduced if fields were limited to likely areas of nodal involvement rather than using the standard 'four-field box.' We employed a novel magnetic resonance lymphangiographic technique to highlight the likely sites of occult nodal metastasis from prostate cancer. Methods and Materials: Eighteen prostate cancer patients with pathologically confirmed node-positive disease had a total of 69 pathologic nodes identifiable by lymphotropic nanoparticle-enhanced MRI and semiquantitative nodal analysis. Fourteen of these nodes were in the para-aortic region, and 55 were in the pelvis. The position of each of these malignant nodes was mapped to amore » common template based on its relation to skeletal or vascular anatomy. Results: Relative to skeletal anatomy, nodes covered a diffuse volume from the mid lumbar spine to the superior pubic ramus and along the sacrum and pelvic side walls. In contrast, the nodal metastases mapped much more tightly relative to the large pelvic vessels. A proposed pelvic clinical target volume to encompass the region at greatest risk of containing occult nodal metastases would include a 2.0-cm radial expansion volume around the distal common iliac and proximal external and internal iliac vessels that would encompass 94.5% of the pelvic nodes at risk as defined by our node-positive prostate cancer patient cohort. Conclusions: Nodal metastases from prostate cancer are largely localized along the major pelvic vasculature. Defining nodal radiation treatment portals based on vascular rather than bony anatomy may allow for a significant decrease in normal pelvic tissue irradiation and its associated toxicities.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cook, John B.; Lin, Terri C.; Detsi, Eric
Tin metal is an attractive negative electrode material to replace graphite in Li-ion batteries due to its high energy density. However, tin undergoes a large volume change upon alloying with Li, which pulverizes the particles, and ultimately leads to short cycling lifetimes. Nevertheless, nanoporous materials have been shown to extend battery life well past what is observed in nonporous material. Despite the exciting potential of porous alloying anodes to significantly increase the energy density in Li-ion batteries, the fundamental physics of how nanoscale architectures accommodate the electrochemically induced volume changes are poorly understood. Here, operando transmission X-ray microscopy has beenmore » used to develop an understanding of the mechanisms that govern the enhanced cycling stability in nanoporous tin. We found that in comparison to dense tin, nanoporous tin undergoes a 6-fold smaller areal expansion after lithiation, as a result of the internal porosity and unique nanoscale architecture. The expansion is also more gradual in nanoporous tin compared to the dense material. The nanoscale resolution of the microscope used in this study is ~30 nm, which allowed us to directly observe the pore structure during lithiation and delithiation. We found that nanoporous tin remains porous during the first insertion and desinsertion cycle. This observation is key, as fully closed pores could lead to mechanical instability, electrolyte inaccessibility, and short lifetimes. Here, while tin was chosen for this study because of its high X-ray contrast, the results of this work should be general to other alloy-type systems, such as Si, that also suffer from volume change based cycling degradation.« less
Alperin, Noam; Bagci, Ahmet M
2018-01-01
Most of the astronauts onboard the International Space Station (ISS) develop visual impairment and ocular structural changes that are not fully reversible upon return to earth. Current understanding assumes that the so-called visual impairments/intracranial pressure (VIIP) syndrome is caused by cephalad vascular fluid shift. This study assesses the roles of cerebrospinal fluid (CSF) and intracranial pressure (ICP) in VIIP. Seventeen astronauts, 9 who flew a short-duration mission on the space shuttle (14.1 days [SD 1.6]) and 7 who flew a long-duration mission on the ISS (188 days [SD 22]) underwent MRI of the brain and orbits to assess the pre-to-post spaceflight changes in four categories: VIIP severity measures: globe flattening and nerve protrusion; orbital and ventricular CSF volumes; cortical gray and white matter volumes; and MR-derived ICP (MRICP). Significant pre-to-post-flight increase in globe flattening and optic nerve protrusion occurred only in the long-duration cohort (0.031 [SD 0.019] vs -0.001 [SD 0.006], and 0.025 [SD 0.013] vs 0.001 [SD 0.006]; p < 0.00002 respectively). The increased globe deformations were associated with significant increases in orbital and ventricular CSF volumes, but not with increased tissue vascular fluid content. Additionally, a moderate increase in MRICP of 6 mmHg was observed in only two ISS astronauts with large ocular structure changes. These findings are evidence for the primary role of CSF and a lesser role for intracranial cephalad fluid-shift in the formation of VIIP. VIIP is caused by a prolonged increase in orbital CSF spaces that compress the globes' posterior pole, even without a large increase in ICP.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Judith Alice; Long, Kevin Nicholas
2017-05-01
This work was done to support customer questions about whether a Sylgard/Glass Microballoon (GMB) potting material in current use could be replaced with pure Sylgard and if this would significantly change stresses imparted to internal components under thermal cycling conditions. To address these questions, we provide micromechanics analysis of Sylgard/GMB materials using both analytic composite theory and finite element simulations to better understand the role of the GMB volume fraction in determining thermal expansion coefficient, elastic constants, and behavior in both confined and unconfined compression boundary value problems. A key finding is that damage accumulation in the material from breakagemore » of GMBs significantly limits the global stress magnitude and results in a plateau stress behavior over large ranges of compressive strain. The magnitude of this plateau stress is reduced with higher volume fractions of GMBs. This effect is particularly pronounced in confined compression, which we estimate bears the most similarity to the application of interest. This stress-limiting damage mechanism is not present in pure Sylgard, however, and the result is much higher stresses under confined compression. Thus, we recommend that some volume fraction greater than 10% GMBs be used for confined deformation applications.« less
Wood in New Zealand's Native Forest Streams. Recent Advances
NASA Astrophysics Data System (ADS)
Mark, M. A.; Davies-Colley, R.
2005-05-01
We conducted a series of research projects to investigate the importance of wood in native forested streams of New Zealand. We examined abundance and geomorphic role of wood in 18 pristine native forest streams (channel width: 3-6 m) throughout New Zealand. Forest type and geographic location had no discernable influence on wood abundance, possibly reflecting the confounding influences of local features (e.g., tree fall regime) and methodology (`snap-shot' survey of a dynamic system). Number (18-66 per 100 m) and dead wood volume (85-470 m3 ha-1) of stream logs were at the high end of the international range. Living trees contributed up to 25% of total wood, and tree ferns were strongly represented (up to 11% of volume). The largest 10% of pieces contributed 75% of the total volume. The importance of the large wood pieces (>10 m3) was explored further with surveys within that watershed containing the site with the greatest wood volume. The largest pieces were rare but seemed relatively uniformly distributed. To explore the biological consequences of stream wood, we studied use of wood-related micro-habitat by the crayfish (Paranephrops planifrons White). Our findings suggest that wood is an important component of New Zealand's forested stream ecosystems.
Global Trends in Educational Policy. International Perspectives on Education and Society. Volume 6
ERIC Educational Resources Information Center
Baker, David, Ed.; Wiseman, Alex, Ed.
2005-01-01
This volume of International Perspectives on Education and Society highlights the valuable role that educational policy plays in the development of education and society around the world. The role of policy in the development of education is crucial. Much rests on the decisions, support, and most of all resources that policymakers can either give…
ERIC Educational Resources Information Center
Thompson, Kenneth W., Ed.; And Others
Presented are the results of a study made by developing country educators for twelve national and international agencies, directed and coordinated by the International Council for Educational Development. Volume 2 contains the reports of 25 case studies of higher education institutions and systems in Africa, Asia, and Latin America: University of…
Large Volume, Behaviorally-relevant Illumination for Optogenetics in Non-human Primates.
Acker, Leah C; Pino, Erica N; Boyden, Edward S; Desimone, Robert
2017-10-03
This protocol describes a large-volume illuminator, which was developed for optogenetic manipulations in the non-human primate brain. The illuminator is a modified plastic optical fiber with etched tip, such that the light emitting surface area is > 100x that of a conventional fiber. In addition to describing the construction of the large-volume illuminator, this protocol details the quality-control calibration used to ensure even light distribution. Further, this protocol describes techniques for inserting and removing the large volume illuminator. Both superficial and deep structures may be illuminated. This large volume illuminator does not need to be physically coupled to an electrode, and because the illuminator is made of plastic, not glass, it will simply bend in circumstances when traditional optical fibers would shatter. Because this illuminator delivers light over behaviorally-relevant tissue volumes (≈ 10 mm 3 ) with no greater penetration damage than a conventional optical fiber, it facilitates behavioral studies using optogenetics in non-human primates.
Ronald E. McRoberts; Paolo Moser; Laio Zimermann Oliveira; Alexander C. Vibrans
2015-01-01
Forest inventory estimates of tree volume for large areas are typically calculated by adding the model predictions of volumes for individual trees at the plot level, calculating the mean over plots, and expressing the result on a per unit area basis. The uncertainty in the model predictions is generally ignored, with the result that the precision of the large-area...
The persistence of the large volumes in black holes
NASA Astrophysics Data System (ADS)
Ong, Yen Chin
2015-08-01
Classically, black holes admit maximal interior volumes that grow asymptotically linearly in time. We show that such volumes remain large when Hawking evaporation is taken into account. Even if a charged black hole approaches the extremal limit during this evolution, its volume continues to grow; although an exactly extremal black hole does not have a "large interior". We clarify this point and discuss the implications of our results to the information loss and firewall paradoxes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, W; Ding, X; Hu, Y
Purpose: To investigate how spot size and spacing affect plan quality, especially, plan robustness and the impact of interplay effect, of robustly-optimized intensity-modulated proton therapy (IMPT) plans for lung cancer. Methods: Two robustly-optimized IMPT plans were created for 10 lung cancer patients: (1) one for a proton beam with in-air energy dependent large spot size at isocenter (σ: 5–15 mm) and spacing (1.53σ); (2) the other for a proton beam with small spot size (σ: 2–6 mm) and spacing (5 mm). Both plans were generated on the average CTs with internal-gross-tumor-volume density overridden to irradiate internal target volume (ITV). Themore » root-mean-square-dose volume histograms (RVH) measured the sensitivity of the dose to uncertainties, and the areas under RVH curves were used to evaluate plan robustness. Dose evaluation software was developed to model time-dependent spot delivery to incorporate interplay effect with randomized starting phases of each field per fraction. Patient anatomy voxels were mapped from phase to phase via deformable image registration to score doses. Dose-volume-histogram indices including ITV coverage, homogeneity, and organs-at-risk (OAR) sparing were compared using Student-t test. Results: Compared to large spots, small spots resulted in significantly better OAR sparing with comparable ITV coverage and homogeneity in the nominal plan. Plan robustness was comparable for ITV and most OARs. With interplay effect considered, significantly better OAR sparing with comparable ITV coverage and homogeneity is observed using smaller spots. Conclusion: Robust optimization with smaller spots significantly improves OAR sparing with comparable plan robustness and similar impact of interplay effect compare to larger spots. Small spot size requires the use of larger number of spots, which gives optimizer more freedom to render a plan more robust. The ratio between spot size and spacing was found to be more relevant to determine plan robustness and the impact of interplay effect than spot size alone. This research was supported by the National Cancer Institute Career Developmental Award K25CA168984, by the Fraternal Order of Eagles Cancer Research Fund Career Development Award, by The Lawrence W. and Marilyn W. Matteson Fund for Cancer Research, by Mayo Arizona State University Seed Grant, and by The Kemper Marley Foundation.« less
Ground Vehicle System Integration (GVSI) and Design Optimization Model.
1996-07-30
number of stowed kills Same basic load lasts longer range Gun/ammo parameters impact system weight, under - armor volume requirements Round volume...internal volume is reduced, the model assumes that the crew’s ability to operate while under armor will be impaired. If the size of a vehicle crew is...changing swept volume will alter under armor volume requirements for the total system; if system volume is fixed, changing swept volume will
Status of the internal orbit after reduction of zygomaticomaxillary complex fractures.
Ellis, Edward; Reddy, Likith
2004-03-01
We sought to determine the status of the internal orbit before and after reduction of zygomaticomaxillary complex (ZMC) fractures when treated without internal orbital reconstruction. We conducted a retrospective study of preoperative and postoperative computed tomography (CT) scans in 65 patients with unilateral ZMC fractures who were treated by reduction of the ZMC complex without internal orbital reconstruction. The size and location of the internal orbital defects, orbital soft tissue displacement, and orbital volume were assessed in the preoperative and postoperative CT scans. Reduction in the ZMC fractures was considered ideal in 58 of the 65 patients. Only minor malpositions occurred in the remaining 7 patients. The size of the internal orbital defects increased slightly with ZMC reduction but the internal orbital fractures were realigned, and few had increases in orbital volume or soft tissue sagging into the sinuses. Examination of follow-up CT scans in several patients taken weeks to months later showed that the residual defects became smaller and that none of these patients had an increase in orbital volume or soft tissue sagging. The preoperative CT scan can be used to assess the amount of internal orbital disruption for purposes of developing a treatment plan in patients with ZMC fractures. When there is minimal or no soft tissue herniation and minimal disruption of the internal orbit, ZMC reduction is adequate treatment.
Dissociable roles of internal feelings and face recognition ability in facial expression decoding.
Zhang, Lin; Song, Yiying; Liu, Ling; Liu, Jia
2016-05-15
The problem of emotion recognition has been tackled by researchers in both affective computing and cognitive neuroscience. While affective computing relies on analyzing visual features from facial expressions, it has been proposed that humans recognize emotions by internally simulating the emotional states conveyed by others' expressions, in addition to perceptual analysis of facial features. Here we investigated whether and how our internal feelings contributed to the ability to decode facial expressions. In two independent large samples of participants, we observed that individuals who generally experienced richer internal feelings exhibited a higher ability to decode facial expressions, and the contribution of internal feelings was independent of face recognition ability. Further, using voxel-based morphometry, we found that the gray matter volume (GMV) of bilateral superior temporal sulcus (STS) and the right inferior parietal lobule was associated with facial expression decoding through the mediating effect of internal feelings, while the GMV of bilateral STS, precuneus, and the right central opercular cortex contributed to facial expression decoding through the mediating effect of face recognition ability. In addition, the clusters in bilateral STS involved in the two components were neighboring yet separate. Our results may provide clues about the mechanism by which internal feelings, in addition to face recognition ability, serve as an important instrument for humans in facial expression decoding. Copyright © 2016 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weckend, Stephanie; Wade, Andreas; Heath, Garvin
Solar photovoltaic (PV) deployment has grown at unprecedented rates since the early 2000s. As the global PV market increases, so will the volume of decommissioned PV panels, and large amounts of annual waste are anticipated by the early 2030s. Growing PV panel waste presents a new environmental challenge, but also unprecedented opportunities to create value and pursue new economic avenues. This report, prepared jointly by the International Renewable Energy Agency (IRENA) and the International Energy Agency Photovoltaic Power Systems Programme (IEA-PVPS), is the first-ever projection of PV panel waste volumes to 2050. It highlights that recycling or repurposing solar PVmore » panels at the end of their roughly 30-year lifetime can unlock an estimated stock of 78 million tonnes of raw materials and other valuable components globally by 2050. If fully injected back into the economy, the value of the recovered material could exceed USD 15 billion by 2050. Sectors like PV recycling will be essential in the world's transition to a sustainable, economically viable and increasingly renewables-based energy future. To unlock the benefits of such PV end-of-life industries, the institutional groundwork must be laid in time to meet the expected surge in panel waste. Policy action is needed to address the challenges ahead, with enabling frameworks being adapted to the needs and circumstances of each region or country.« less
1989-04-01
1 AD-A257 318 Proceedings of the Fourth International Symposium on the Interaction of Non-nuclear Munfftons with Structures (volume 2) DTIC S ELECTE...volume 2) 6. AUTHOR( S ) Captain Diane B. Miller (Symposium Project Officer) 7. PERFORMING ORGANIZATION NAME( S ) ANI) ADDRESS(ES) 8. PEBF()WING...MONITORING AGENCY NAME( S ) AND ADDRESS(ES) - 10. SPONSORINGiMONITORING AGENCY REPORT NUMBER (Same as 7) 11, SUPPLEMENTARY NOTES 12a. DISTRIBUTION
Besemer, Abigail E; Titz, Benjamin; Grudzinski, Joseph J; Weichert, Jamey P; Kuo, John S; Robins, H Ian; Hall, Lance T; Bednarz, Bryan P
2017-07-06
Variations in tumor volume segmentation methods in targeted radionuclide therapy (TRT) may lead to dosimetric uncertainties. This work investigates the impact of PET and MRI threshold-based tumor segmentation on TRT dosimetry in patients with primary and metastatic brain tumors. In this study, PET/CT images of five brain cancer patients were acquired at 6, 24, and 48 h post-injection of 124 I-CLR1404. The tumor volume was segmented using two standardized uptake value (SUV) threshold levels, two tumor-to-background ratio (TBR) threshold levels, and a T1 Gadolinium-enhanced MRI threshold. The dice similarity coefficient (DSC), jaccard similarity coefficient (JSC), and overlap volume (OV) metrics were calculated to compare differences in the MRI and PET contours. The therapeutic 131 I-CLR1404 voxel-level dose distribution was calculated from the 124 I-CLR1404 activity distribution using RAPID, a Geant4 Monte Carlo internal dosimetry platform. The TBR, SUV, and MRI tumor volumes ranged from 2.3-63.9 cc, 0.1-34.7 cc, and 0.4-11.8 cc, respectively. The average ± standard deviation (range) was 0.19 ± 0.13 (0.01-0.51), 0.30 ± 0.17 (0.03-0.67), and 0.75 ± 0.29 (0.05-1.00) for the JSC, DSC, and OV, respectively. The DSC and JSC values were small and the OV values were large for both the MRI-SUV and MRI-TBR combinations because the regions of PET uptake were generally larger than the MRI enhancement. Notable differences in the tumor dose volume histograms were observed for each patient. The mean (standard deviation) 131 I-CLR1404 tumor doses ranged from 0.28-1.75 Gy GBq -1 (0.07-0.37 Gy GBq -1 ). The ratio of maximum-to-minimum mean doses for each patient ranged from 1.4-2.0. The tumor volume and the interpretation of the tumor dose is highly sensitive to the imaging modality, PET enhancement metric, and threshold level used for tumor volume segmentation. The large variations in tumor doses clearly demonstrate the need for standard protocols for multimodality tumor segmentation in TRT dosimetry.
NASA Astrophysics Data System (ADS)
Besemer, Abigail E.; Titz, Benjamin; Grudzinski, Joseph J.; Weichert, Jamey P.; Kuo, John S.; Robins, H. Ian; Hall, Lance T.; Bednarz, Bryan P.
2017-08-01
Variations in tumor volume segmentation methods in targeted radionuclide therapy (TRT) may lead to dosimetric uncertainties. This work investigates the impact of PET and MRI threshold-based tumor segmentation on TRT dosimetry in patients with primary and metastatic brain tumors. In this study, PET/CT images of five brain cancer patients were acquired at 6, 24, and 48 h post-injection of 124I-CLR1404. The tumor volume was segmented using two standardized uptake value (SUV) threshold levels, two tumor-to-background ratio (TBR) threshold levels, and a T1 Gadolinium-enhanced MRI threshold. The dice similarity coefficient (DSC), jaccard similarity coefficient (JSC), and overlap volume (OV) metrics were calculated to compare differences in the MRI and PET contours. The therapeutic 131I-CLR1404 voxel-level dose distribution was calculated from the 124I-CLR1404 activity distribution using RAPID, a Geant4 Monte Carlo internal dosimetry platform. The TBR, SUV, and MRI tumor volumes ranged from 2.3-63.9 cc, 0.1-34.7 cc, and 0.4-11.8 cc, respectively. The average ± standard deviation (range) was 0.19 ± 0.13 (0.01-0.51), 0.30 ± 0.17 (0.03-0.67), and 0.75 ± 0.29 (0.05-1.00) for the JSC, DSC, and OV, respectively. The DSC and JSC values were small and the OV values were large for both the MRI-SUV and MRI-TBR combinations because the regions of PET uptake were generally larger than the MRI enhancement. Notable differences in the tumor dose volume histograms were observed for each patient. The mean (standard deviation) 131I-CLR1404 tumor doses ranged from 0.28-1.75 Gy GBq-1 (0.07-0.37 Gy GBq-1). The ratio of maximum-to-minimum mean doses for each patient ranged from 1.4-2.0. The tumor volume and the interpretation of the tumor dose is highly sensitive to the imaging modality, PET enhancement metric, and threshold level used for tumor volume segmentation. The large variations in tumor doses clearly demonstrate the need for standard protocols for multimodality tumor segmentation in TRT dosimetry.
The physics of large eruptions
NASA Astrophysics Data System (ADS)
Gudmundsson, Agust
2015-04-01
Based on eruptive volumes, eruptions can be classified as follows: small if the volumes are from less than 0.001 km3 to 0.1 km3, moderate if the volumes are from 0.1 to 10 km3, and large if the volumes are from 10 km3 to 1000 km3 or larger. The largest known explosive and effusive eruptions have eruptive volumes of 4000-5000 km3. The physics of small to moderate eruptions is reasonably well understood. For a typical mafic magma chamber in a crust that behaves as elastic, about 0.1% of the magma leaves the chamber (erupted and injected as a dyke) during rupture and eruption. Similarly, for a typical felsic magma chamber, the eruptive/injected volume during rupture and eruption is about 4%. To provide small to moderate eruptions, chamber volumes of the order of several tens to several hundred cubic kilometres would be needed. Shallow crustal chambers of these sizes are common, and deep-crustal and upper-mantle reservoirs of thousands of cubic kilometres exist. Thus, elastic and poro-elastic chambers of typical volumes can account for small to moderate eruptive volumes. When the eruptions become large, with volumes of tens or hundreds of cubic kilometres or more, an ordinary poro-elastic mechanism can no longer explain the eruptive volumes. The required sizes of the magma chambers and reservoirs to explain such volumes are simply too large to be plausible. Here I propose that the mechanics of large eruptions is fundamentally different from that of small to moderate eruptions. More specifically, I suggest that all large eruptions derive their magmas from chambers and reservoirs whose total cavity-volumes are mechanically reduced very much during the eruption. There are two mechanisms by which chamber/reservoir cavity-volumes can be reduced rapidly so as to squeeze out much of, or all, their magmas. One is piston-like caldera collapse. The other is graben subsidence. During large slip on the ring-faults/graben-faults the associated chamber/reservoir shrinks in volume, thereby maintaining the excess magmatic pressure much longer than is possible in the ordinary poro-elastic mechanism. Here the physics of caldera subsidence and graben subsidence is regarded as basically the same. The geometric difference in the surface expression is simply a reflection of the horizontal cross-sectional shape of the underlying magma body. In this new mechanism, the large eruption is the consequence -- not the cause -- of the caldera/graben subsidence. Thus, once the conditions for large-scale subsidence of a caldera/graben during an unrest period are established, then the likelihood of large to very large eruptions can be assessed and used in reliable forecasting. Gudmundsson, A., 2012. Strengths and strain energies of volcanic edifices: implications for eruptions, collapse calderas and landslides. Nat. Hazards Earth Syst. Sci., 12, 2241-2258. Gudmundsson, A., 2014. Energy release in great earthquakes and eruptions. Front. Earth Science 2:10. doi: 10.3389/feart.2014.00010 Gudmundsson, A., Acocella, V., 2015.Volcanotectonics: Understanding the Structure, Deformation, and Dynamics of Volcanoes. Cambridge University Press (published 2015).
ERIC Educational Resources Information Center
McConnell, Grant D., Ed.; Gendron, Jean-Denis, Ed.
The atlas offers a cartography of language functions, quantitatively measured in vitality rates, for Western Europe. The atlas has three parts: vitality by language; vitality by domain; and vitality by country. Eighty-three minority languages are covered. Domains considered include: global; religion; schools; mass media; administration; courts;…
ERIC Educational Resources Information Center
Raby, Rosalind Latiner, Ed.; Tarrow, Norma, Ed.
This two-part monograph provides a theoretical and practical analyses of intercultural and multicultural education programs. The first part describes inter- and multicultural educational programs in the United States and Canada and includes the following eight chapters: "International, Intercultural, and Multicultural Dimensions of Community…
ERIC Educational Resources Information Center
Woo, Jeong-Ho, Ed.; Lew, Hee-Chan, Ed.; Park, Kyo-Sik Park, Ed.; Seo, Dong-Yeop, Ed.
2007-01-01
The first volume of the 31st annual proceedings of the International Group for the Psychology of Mathematics Education conference presents plenary lectures; research forums; discussion groups; working sessions; short oral communications; and posters from the meeting. Plenary lecture papers include: (1) On Humanistic Mathematics Education: A…
Ragagnin, Marilia Nagata; Gorman, Daniel; McCarthy, Ian Donald; Sant'Anna, Bruno Sampaio; de Castro, Cláudio Campi; Turra, Alexander
2018-01-11
Obtaining accurate and reproducible estimates of internal shell volume is a vital requirement for studies into the ecology of a range of shell-occupying organisms, including hermit crabs. Shell internal volume is usually estimated by filling the shell cavity with water or sand, however, there has been no systematic assessment of the reliability of these methods and moreover no comparison with modern alternatives, e.g., computed tomography (CT). This study undertakes the first assessment of the measurement reproducibility of three contrasting approaches across a spectrum of shell architectures and sizes. While our results suggested a certain level of variability inherent for all methods, we conclude that a single measure using sand/water is likely to be sufficient for the majority of studies. However, care must be taken as precision may decline with increasing shell size and structural complexity. CT provided less variation between repeat measures but volume estimates were consistently lower compared to sand/water and will need methodological improvements before it can be used as an alternative. CT indicated volume may be also underestimated using sand/water due to the presence of air spaces visible in filled shells scanned by CT. Lastly, we encourage authors to clearly describe how volume estimates were obtained.
Growth Chambers on the International Space Station for Large Plants
NASA Technical Reports Server (NTRS)
Massa, G. D.; Wheeler, R. M.; Morrow, R. C.; Levine, H. G.
2016-01-01
The International Space Station (ISS) now has platforms for conducting research on horticultural plant species under LED lighting, and those capabilities continue to expand. The 'Veggie' vegetable production system was deployed to the ISS as an applied research platform for food production in space. Veggie is capable of growing a wide array of horticultural crops. It was designed for low power usage, low launch mass and stowage volume, and minimal crew time requirements. The Veggie flight hardware consists of a light cap containing red (630 nm), blue, (455 nm) and green (530 nm) LEDs. Interfacing with the light cap is an extendable bellows/baseplate for enclosing the plant canopy. A second large plant growth chamber, the Advanced Plant Habitat (APH), is will fly to the ISS in 2017. APH will be a fully controllable environment for high-quality plant physiological research. APH will control light (quality, level, and timing), temperature, CO2, relative humidity, and irrigation, while scrubbing any cabin or plant-derived ethylene and other volatile organic compounds. Additional capabilities include sensing of leaf temperature and root zone moisture, root zone temperature, and oxygen concentration. The light cap will have red (630 nm), blue (450 nm), green (525 nm), far red (730 nm) and broad spectrum white LEDs (4100K). There will be several internal cameras (visible and IR) to monitor and record plant growth and operations. Veggie and APH are available for research proposals.
McCollough, Cynthia H; Ulzheimer, Stefan; Halliburton, Sandra S; Shanneik, Kaiss; White, Richard D; Kalender, Willi A
2007-05-01
To develop a consensus standard for quantification of coronary artery calcium (CAC). A standard for CAC quantification was developed by a multi-institutional, multimanufacturer international consortium of cardiac radiologists, medical physicists, and industry representatives. This report specifically describes the standardization of scan acquisition and reconstruction parameters, the use of patient size-specific tube current values to achieve a prescribed image noise, and the use of the calcium mass score to eliminate scanner- and patient size-based variations. An anthropomorphic phantom containing calibration inserts and additional phantom rings were used to simulate small, medium-size, and large patients. The three phantoms were scanned by using the recommended protocols for various computed tomography (CT) systems to determine the calibration factors that relate measured CT numbers to calcium hydroxyapatite density and to determine the tube current values that yield comparable noise values. Calculation of the calcium mass score was standardized, and the variance in Agatston, volume, and mass scores was compared among CT systems. Use of the recommended scanning parameters resulted in similar noise for small, medium-size, and large phantoms with all multi-detector row CT scanners. Volume scores had greater interscanner variance than did Agatston and calcium mass scores. Use of a fixed calcium hydroxyapatite density threshold (100 mg/cm(3)), as compared with use of a fixed CT number threshold (130 HU), reduced interscanner variability in Agatston and calcium mass scores. With use of a density segmentation threshold, the calcium mass score had the smallest variance as a function of patient size. Standardized quantification of CAC yielded comparable image noise, spatial resolution, and mass scores among different patient sizes and different CT systems and facilitated reduced radiation dose for small and medium-size patients.
NASA Technical Reports Server (NTRS)
Edberg, Stephen J. (Editor)
1996-01-01
The International Halley Watch (IHW) was organized for the purpose of gathering and archiving the most complete record of the apparition of a comet, Comet Halley (1982i = 1986 III = 1P/Halley), ever compiled. The redirection of the International Cometary Explorer (ICE), toward Comet Giacobini-Zinner (1984e = 1985 XIII = 21P/Giacobini-Zinner) prompted the initiation of a formal watch on that comet. All the data collected on P/Giacobini-Zinner and P/Halley have been published on CD-ROM in the Comet Halley Archive. This document contains a printed version of the archive data, collected by amateur astronomers, on these two comets. Volume 1 contains the Comet Giacobini-Zinner data archive and Volume 2 contains the Comet Halley archive. Both volumes include information on how to read the data in both archives, as well as a history of both comet watches (including the organizing of the network of astronomers and lessons learned from that experience).
NASA Astrophysics Data System (ADS)
Popov, V. N.; Botygin, I. A.; Kolochev, A. S.
2017-01-01
The approach allows representing data of international codes for exchange of meteorological information using metadescription as the formalism associated with certain categories of resources. Development of metadata components was based on an analysis of the data of surface meteorological observations, atmosphere vertical sounding, atmosphere wind sounding, weather radar observing, observations from satellites and others. A common set of metadata components was formed including classes, divisions and groups for a generalized description of the meteorological data. The structure and content of the main components of a generalized metadescription are presented in detail by the example of representation of meteorological observations from land and sea stations. The functional structure of a distributed computing system is described. It allows organizing the storage of large volumes of meteorological data for their further processing in the solution of problems of the analysis and forecasting of climatic processes.
Nugawela, Manjula D.; Langley, Tessa; Szatkowski, Lisa; Lewis, Sarah
2016-01-01
Aims To review the international guidelines and recommendations on survey instruments for measurement of alcohol consumption in population surveys and to examine how national surveys in England meet the core recommendations. Methods A systematic search for international guidelines for measuring alcohol consumption in population surveys was undertaken. The common core recommendations for alcohol consumption measures and survey instruments were identified. Alcohol consumption questions in national surveys in England were compared with these recommendations for specific years and over time since 2000. Results Four sets of international guidelines and three core alcohol consumption measures (alcohol consumption status, average volume of consumption, frequency and volume of heavy episodic drinking) with another optional measure (drinking context) were identified. English national surveys have been inconsistent over time in including questions that provide information on average volume of consumption but have not included questions on another essential alcohol consumption measure, frequency of heavy episodic drinking. Instead, they have used questions that focus only on maximum volume of alcohol consumed on any day in the previous week. Conclusions International guidelines provide consistent recommendations for measuring alcohol consumption in population surveys. These recommendations have not been consistently applied in English national surveys, and this has contributed to the inadequacy of survey measurements for monitoring vital aspects of alcohol consumption in England over recent years. PMID:26115987
Large volume continuous counterflow dialyzer has high efficiency
NASA Technical Reports Server (NTRS)
Mandeles, S.; Woods, E. C.
1967-01-01
Dialyzer separates macromolecules from small molecules in large volumes of solution. It takes advantage of the high area/volume ratio in commercially available 1/4-inch dialysis tubing and maintains a high concentration gradient at the dialyzing surface by counterflow.
Red Blood Cell Mechanical Fragility Test for Clinical Research Applications.
Ziegler, Luke A; Olia, Salim E; Kameneva, Marina V
2017-07-01
Red blood cell (RBC) susceptibility to mechanically induced hemolysis, or RBC mechanical fragility (MF), is an important parameter in the characterization of erythrocyte membrane health. The rocker bead test (RBT) and associated calculated mechanical fragility index (MFI) is a simple method for the assessment of RBC MF. Requiring a minimum of 15.5 mL of blood and necessitating adjustment of hematocrit (Ht) to a "standard" value (40%), the current RBT is not suitable for use in most studies involving human subjects. To address these limitations, we propose a 6.5 mL reduced volume RBT and corresponding modified MFI (MMFI) that does not require prior Ht adjustment. This new method was assessed for i) correlation to the existing text, ii) to quantify the effect of Ht on MFI, and iii) validation by reexamining the protective effect of plasma proteins on RBC MF. The reduced volume RBT strongly correlated (r = 0.941) with the established large volume RBT at matched Hts, and an equation was developed to calculate MMFI: a numerical estimation (R 2 = 0.923) of MFI if performed with the reduced volume RBT at "standard" (40%) Ht. An inversely proportional relationship was found between plasma protein concentration and RBC MF using the MMFI-reduced volume method, supporting previous literature findings. The new reduced volume RBT and modified MFI will allow for the measurement of RBC MF in clinical and preclinical studies involving humans or small animals. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
The NANOGrav Observing Program: Automation and Reproducibility
NASA Astrophysics Data System (ADS)
Brazier, Adam; Cordes, James; Demorest, Paul; Dolch, Timothy; Ferdman, Robert; Garver-Daniels, Nathaniel; Hawkins, Steven; Lam, Michael Timothy; Lazio, T. Joseph W.
2018-01-01
The NANOGrav Observing Program is a decades-long search for gravitational waves using pulsar timing which relies, for its sensitivity, on large data sets from observations of many pulsars. These are constructed through an intensive, long-term observing campaign. The nature of the program requires automation in the transfer and archiving of the large volume of raw telescope data, the calibration of those data, and making these resulting data products—required for diagnostic and data exploration purposes—available to NANOGrav members. Reproducibility of results is a key goal in this project, and essential to its success; it requires treating the software itself as a data product of the research, while ensuring easy access by, and collaboration between, members of NANOGrav, the International Pulsar Timing Array consortium (of which NANOGrav is a key member), as well as the wider astronomy community and the public.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clements, N.; Kron, T.; Roxby, P.
2013-02-15
Purpose: Stereotactic lung radiotherapy is complicated by tumor motion from patient respiration. Four-dimensional CT (4DCT) imaging is a motion compensation method used in treatment planning to generate a maximum intensity projection (MIP) internal target volume (ITV). Image guided radiotherapy during treatment may involve acquiring a volumetric cone-beam CT (CBCT) image and visually aligning the tumor to the planning 4DCT MIP ITV contour. Moving targets imaged with CBCT can appear blurred and currently there are no studies reporting on the effect that irregular breathing patterns have on CBCT volumes and their alignment to 4DCT MIP ITV contours. The objective of thismore » work was therefore to image a phantom moving with irregular breathing patterns to determine whether any configurations resulted in errors in volume contouring or alignment. Methods: A Perspex thorax phantom was used to simulate a patient. Three wooden 'lung' inserts with embedded Perspex 'lesions' were moved up to 4 cm with computer-generated motion patterns, and up to 1 cm with patient-specific breathing patterns. The phantom was imaged on 4DCT and CBCT with the same acquisition settings used for stereotactic lung patients in the clinic and the volumes on all phantom images were contoured. This project assessed the volumes for qualitative and quantitative changes including volume, length of the volume, and errors in alignment between CBCT volumes and 4DCT MIP ITV contours. Results: When motion was introduced 4DCT and CBCT volumes were reduced by up to 20% and 30% and shortened by up to 7 and 11 mm, respectively, indicating that volume was being under-represented at the extremes of motion. Banding artifacts were present in 4DCT MIP images, while CBCT volumes were largely reduced in contrast. When variable amplitudes from patient traces were used and CBCT ITVs were compared to 4DCT MIP ITVs there was a distinct trend in reduced ITV with increasing amplitude that was not seen when compared to true ITVs. Breathing patterns with a rest period following expiration resulted in well-defined superior edges and were better aligned using an edge-to-edge alignment technique. In most cases, sinusoidal motion patterns resulted in the closest agreements to true values and the smallest misalignments. Conclusions: Strategies are needed to compensate for volume losses at the extremes of motion for both 4DCT MIP and CBCT images for larger and varied amplitudes, and for patterns with rest periods following expiration. Lesions moving greater than 2 cm would warrant larger treatment margins added to the 4DCT MIP ITV to account for the volume being under-represented at the extremes of motion. Lesions moving with a rest period following expiration would be better aligned using an edge-to-edge alignment technique. Sinusoidal patterns represented the ideal clinical scenario, reinforcing the importance of investigating clinically relevant motions and their effects on 4DCT MIP and CBCT volumes. Since most patients do not breathe sinusoidally this may lead to misinterpretation of previous studies using only sinusoidal motion.« less
Clements, N; Kron, T; Franich, R; Dunn, L; Roxby, P; Aarons, Y; Chesson, B; Siva, S; Duplan, D; Ball, D
2013-02-01
Stereotactic lung radiotherapy is complicated by tumor motion from patient respiration. Four-dimensional CT (4DCT) imaging is a motion compensation method used in treatment planning to generate a maximum intensity projection (MIP) internal target volume (ITV). Image guided radiotherapy during treatment may involve acquiring a volumetric cone-beam CT (CBCT) image and visually aligning the tumor to the planning 4DCT MIP ITV contour. Moving targets imaged with CBCT can appear blurred and currently there are no studies reporting on the effect that irregular breathing patterns have on CBCT volumes and their alignment to 4DCT MIP ITV contours. The objective of this work was therefore to image a phantom moving with irregular breathing patterns to determine whether any configurations resulted in errors in volume contouring or alignment. A Perspex thorax phantom was used to simulate a patient. Three wooden "lung" inserts with embedded Perspex "lesions" were moved up to 4 cm with computer-generated motion patterns, and up to 1 cm with patient-specific breathing patterns. The phantom was imaged on 4DCT and CBCT with the same acquisition settings used for stereotactic lung patients in the clinic and the volumes on all phantom images were contoured. This project assessed the volumes for qualitative and quantitative changes including volume, length of the volume, and errors in alignment between CBCT volumes and 4DCT MIP ITV contours. When motion was introduced 4DCT and CBCT volumes were reduced by up to 20% and 30% and shortened by up to 7 and 11 mm, respectively, indicating that volume was being under-represented at the extremes of motion. Banding artifacts were present in 4DCT MIP images, while CBCT volumes were largely reduced in contrast. When variable amplitudes from patient traces were used and CBCT ITVs were compared to 4DCT MIP ITVs there was a distinct trend in reduced ITV with increasing amplitude that was not seen when compared to true ITVs. Breathing patterns with a rest period following expiration resulted in well-defined superior edges and were better aligned using an edge-to-edge alignment technique. In most cases, sinusoidal motion patterns resulted in the closest agreements to true values and the smallest misalignments. Strategies are needed to compensate for volume losses at the extremes of motion for both 4DCT MIP and CBCT images for larger and varied amplitudes, and for patterns with rest periods following expiration. Lesions moving greater than 2 cm would warrant larger treatment margins added to the 4DCT MIP ITV to account for the volume being under-represented at the extremes of motion. Lesions moving with a rest period following expiration would be better aligned using an edge-to-edge alignment technique. Sinusoidal patterns represented the ideal clinical scenario, reinforcing the importance of investigating clinically relevant motions and their effects on 4DCT MIP and CBCT volumes. Since most patients do not breathe sinusoidally this may lead to misinterpretation of previous studies using only sinusoidal motion.
An Experimental Investigation of the Laminar Flamelet Concept for Soot Properties
NASA Technical Reports Server (NTRS)
Diez, F. J.; Aalburg, C.; Sunderland, P. B.; Urban, D. L.; Yuan, Z.-G.; Faeth, G. M.
2007-01-01
The soot properties of round, nonbuoyant, laminar jet diffusion flames are described, based on experiments at microgravity carried out on orbit during three flights of the Space Shuttle Columbia, (Flights STS-83, 94 and 107). Experimental conditions included ethylene- and propane-fueled flames burning in still air at an ambient temperature of 300 K and ambient pressures of 35-100 kPa. Measurements included soot volume fraction distributions using deconvoluted laser extinction imaging, and soot temperature distributions using deconvoluted multiline emission imaging. Flowfield modeling based on the work of Spalding is presented. The present work explores whether soot properties of these flames are universal functions of mixture fraction, i.e., whether they satisfy soot state relationships. Measurements are presented, including radiative emissions and distributions of soot temperature and soot volume fraction. It is shown that most of the volume of these flames is bounded by the dividing streamline and thus should follow residence time state relationships. Most streamlines from the fuel supply to the surroundings are found to exhibit nearly the same maximum soot volume fraction and temperature. The radiation intensity along internal streamlines also is found to have relatively uniform values. Finally, soot state relationships were observed, i.e., soot volume fraction was found to correlate with estimated mixture fraction for each fuel/pressure selection. These results support the existence of soot property state relationships for steady nonbuoyant laminar diffusion flames, and thus in a large class of practical turbulent diffusion flames through the application of the laminar flamelet concept.
ERIC Educational Resources Information Center
Porfilio, Bradley, Ed.; Hickman, Heather, Ed.
2011-01-01
This volume will be a valuable resource to instructors who teach in the fields of teacher education, social studies, educational leadership, social work, social, cultural and philosophical foundations of education, sociology, political science, and global studies as well as their students. Due to the volume's international focus, the authors also…
The three-volumes document 82 presentations by authors from 15 countries at the Second International Conference on Municipal Waste Combustion (MWC) in Tampa, Florida, April 16-19, 1991. The Conference fostered the exchange of current information on research concerning MWC, ash di...
The three-volumes document 82 presentations by authors from 15 countries at the Second International Conference on Municipal Waste Combustion (MWC) in Tampa, Florida, April 16-19, 1991. The Conference fostered the exchange of current information on research concerning MWC, ash di...
The three-volumes document 82 presentations by authors from 15 countries at the Second International Conference on Municipal Waste Combustion (MWC) in Tampa, Florida, April 16-19, 1991. The Conference fostered the exchange of current information on research concerning MWC, ash di...
ERIC Educational Resources Information Center
Alexander Graham Bell Association for the Deaf, Inc., Washington, DC.
THE PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON ORAL EDUCATION OF THE DEAF ARE THE WRITTEN RECORD OF A CONFERENCE HELD AT CLARKE SCHOOL FOR THE DEAF AND LEXINGTON SCHOOL FOR THE DEAF IN JUNE 1967. VOLUME I CONTAINS THE PAPERS FROM FIVE PLENARY SESSIONS AND SEVERAL SECTIONAL MEETINGS PRESENTED BY REPRESENTATIVES FROM 16 COUNTRIES. SUBJECTS…
ERIC Educational Resources Information Center
Pehkonen, Erkki, Ed.
The fourth volume of the proceedings of 21st annual meeting of the International Group for the Psychology of Mathematics Education contains the following papers: (1) "A Model for Discriminating amongst Student Teachers of Mathematics" (P. Perks); (2) "A Study of Teachers' Conceptions about Mathematics" (G.N. Philippou and C.…
ERIC Educational Resources Information Center
Pehkonen, Erkki, Ed.
The first volume of the proceedings of the 21st annual meeting of the International Group for the Psychology of Mathematics Education contains the following 13 full papers: (1) "Some Psychological Issues in the Assessment of Mathematical Performance" (O. Bjorkqvist); (2) "Neuromagnetic Approach in Cognitive Neuroscience" (S.…
ERIC Educational Resources Information Center
Nakahara, Tadao, Ed.; Koyama, Masataka, Ed.
The third volume of the 24th annual conference of the International Group for the Psychology of Mathematics Education contains full research report papers. Papers include: (1) "Mathematics classrooms functioning as communities of inquiry: Possibilities and constraints for changing practice" (Susie Groves, Brian Doig, and Laurance Splitter); (2)…
ERIC Educational Resources Information Center
Woo, Jeong-Ho, Ed.; Lew, Hee-Chan, Ed.; Park, Kyo-Sik, Ed.; Seo, Dong-Yeop, Ed.
2007-01-01
This fourth and final volume of the 31st annual proceedings of the International Group for the Psychology of Mathematics Education conference presents research reports for author surnames beginning Na- through Zod-. Reports include: (1) Mathematically Gifted Students' Problem Solving Approaches on Conditional Probability (GwiSoo Na, DaeHee Han,…
ERIC Educational Resources Information Center
Garnier, Helen E.; Lemmens, Meike; Druker, Stephen L.; Roth, Kathleen J.
2011-01-01
This second volume of the Third International Mathematics and Science Study (TIMSS) 1999 Video Study Technical Report focuses on every aspect of the planning, implementation, processing, analysis, and reporting of the science components of the TIMSS 1999 Video Study. The report is intended to serve as a record of the actions and documentation of…
Eighth international congress on nitrogen fixation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1990-01-01
This volume contains the proceedings of the Eighth International Congress on Nitrogen Fixation held May 20--26, 1990 in Knoxville, Tennessee. The volume contains abstracts of individual presentations. Sessions were entitled Recent Advances in the Chemistry of Nitrogen Fixation, Plant-microbe Interactions, Limiting Factors of Nitrogen Fixation, Nitrogen Fixation and the Environment, Bacterial Systems, Nitrogen Fixation in Agriculture and Industry, Plant Function, and Nitrogen Fixation and Evolution.
Eighth international congress on nitrogen fixation. Final program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1990-12-31
This volume contains the proceedings of the Eighth International Congress on Nitrogen Fixation held May 20--26, 1990 in Knoxville, Tennessee. The volume contains abstracts of individual presentations. Sessions were entitled Recent Advances in the Chemistry of Nitrogen Fixation, Plant-microbe Interactions, Limiting Factors of Nitrogen Fixation, Nitrogen Fixation and the Environment, Bacterial Systems, Nitrogen Fixation in Agriculture and Industry, Plant Function, and Nitrogen Fixation and Evolution.
ERIC Educational Resources Information Center
Kokaska, Charles J., Ed.
The document contains 16 papers on program implementation in the career development of the handicapped, and is one of three volumes of selected papers presented at a November, 1981, international conference on the career development of handicapped individuals. Papers have the following titles and authors: "A Career Education Materials Development…
ERIC Educational Resources Information Center
Furinghetti, Fulvia, Ed.
This document, the first of three volumes, reports on the 15th annual conference of the International Group for the Psychology of Mathematics Education (PME) held in Italy 1991. Plenary addresses and speakers are: "Social Interaction and Mathematical Knowledge" (B. M. Bartolini); "Meaning: Image Schemata and Protocols" (W.…
ERIC Educational Resources Information Center
Pehkonen, Erkki, Ed.
The third volume of the proceedings of 21st annual meeting of the International Group for the Psychology of Mathematics Education contains the following papers: (1) "Graphics Calculators Use in Precalculus and Achievement in Calculus" (P. Gomez and F. Femandez); (2) "Tapping into Algebraic Variables through the Graphic…
ERIC Educational Resources Information Center
Woo, Jeong-Ho, Ed.; Lew, Hee-Chan, Ed.; Park, Kyo-Sik Park, Ed.; Seo, Dong-Yeop, Ed.
2007-01-01
This third volume of the 31st annual proceedings of the International Group for the Psychology of Mathematics Education conference presents research reports for author surnames beginning Han- through Miy-. Reports include: (1) Elementary Education Students' Memories of Mathematics in Family Context (Markku S. Hannula, Raimo Kaasila, Erkki…
ERIC Educational Resources Information Center
Woo, Jeong-Ho, Ed.; Lew, Hee-Chan, Ed.; Park, Kyo-Sik Park, Ed.; Seo, Dong-Yeop, Ed.
2007-01-01
This second volume of the 31st annual proceedings of the International Group for the Psychology of Mathematics Education conference presents research reports for author surnames beginning Alc- through Hal-. Reports include: (1) How Do Your Students Think about Proof? A DVD Resource for Mathematicians (Lara Alcock); (2) Teachers' Conceptions of…
ERIC Educational Resources Information Center
Novotna, Jarmila, Ed.; Moraova, Hana, Ed.; Kratka, Magdalena, Ed.; Stehlikova, Nad'a, Ed.
2006-01-01
This volume of the 30th annual proceedings of the International Group for the Psychology of Mathematics Education conference presents: plenary panel papers; research forum papers; short oral communication papers; and poster presentation papers from the meeting. Information relating to discussion groups and working sessions is also provided.…
ERIC Educational Resources Information Center
Pehkonen, Erkki, Ed.
The second volume of the proceedings of 21st annual meeting of the International Group for the Psychology of Mathematics Education contains the following papers: (1) "The Dilemma of Transparency: Seeing and Seeing through Talk in the Mathematics Classroom" (J. Adler); (2) "Abstraction is Hard in Computer-Science Too" (D.…
International training course on nuclear materials accountability for safeguards purposes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1980-12-01
The two volumes of this report incorporate all lectures and presentations at the International Training Course on Nuclear Materials Accountability and Control for Safeguards Purposes, held May 27-June 6, 1980, at the Bishop's Lodge near Santa Fe, New Mexico. The course, authorized by the US Nuclear Non-Proliferation Act and sponsored by the US Department of Energy in cooperation with the International Atomic Energy Agency, was developed to provide practical training in the design, implementation, and operation of a National system of nuclear materials accountability and control that satisfies both National and IAEA International safeguards objectives. Volume I, covering the firstmore » week of the course, presents the background, requirements, and general features of material accounting and control in modern safeguard systems. Volume II, covering the second week of the course, provides more detailed information on measurement methods and instruments, practical experience at power reactor and research reactor facilities, and examples of operating state systems of accountability and control.« less
The Bill of Rights in Action, 2002-2003.
ERIC Educational Resources Information Center
Martz, Carlton
2003-01-01
This document includes the following issues of this journal: volume 18, number 3, Summer 2002; volume 18, number 4, Fall 2002; volume 19, number 2, Spring 2003; and volume 19, number 3, Summer 2003. The summer 2002 issue of "The Bill of Rights in Action" views problems related to victims of war. It focuses on the internment of Japanese…
Burgherr, Peter
2007-02-09
This study gives a global overview of accidental oil spills from all sources (> or =700t) for the period 1970-2004, followed by a detailed examination of trends in accidental tanker spills. The present analysis of the number and volume of tanker spills includes temporal and spatial spill trends, aspects of spill size distribution as well as trends of key factors (i.e., flag state, hull type, tanker age, accident cause and sensitivity of location). Results show that the total number and volume of tanker spills have significantly decreased since the 1970s, which is in contrast to increases in maritime transport of oil and to popular perceptions following recent catastrophic events. However, many spills still occur in ecologically sensitive locations because the major maritime transport routes often cross the boundaries of the Large Marine Ecosystems, but the substantially lower total spill volume is an important contribution to potentially reduce overall ecosystem impacts. In summary, the improvements achieved in the past decades have been the result of a set of initiatives and regulations implemented by governments, international organizations and the shipping industry.
NASA Astrophysics Data System (ADS)
Lorenzi, M.; Mitroglou, N.; Santini, M.; Gavaises, M.
2017-03-01
An experimental technique for the estimation of the temporal-averaged vapour volume fraction within high-speed cavitating flow orifices is presented. The scientific instrument is designed to employ X-ray micro computed tomography (microCT) as a quantitative 3D measuring technique applied to custom designed, large-scale, orifice-type flow channels made from Polyether-ether-ketone (PEEK). The attenuation of the ionising electromagnetic radiation by the fluid under examination depends on its local density; the transmitted radiation through the cavitation volume is compared to the incident radiation, and combination of radiographies from sufficient number of angles leads to the reconstruction of attenuation coefficients versus the spatial position. This results to a 3D volume fraction distribution measurement of the developing multiphase flow. The experimental results obtained are compared against the high speed shadowgraph visualisation images obtained in an optically transparent nozzle with identical injection geometry; comparison between the temporal mean image and the microCT reconstruction shows excellent agreement. At the same time, the real 3D internal channel geometry (possibly eroded) has been measured and compared to the nominal manufacturing CAD drawing of the test nozzle.
Lorenzi, M; Mitroglou, N; Santini, M; Gavaises, M
2017-03-01
An experimental technique for the estimation of the temporal-averaged vapour volume fraction within high-speed cavitating flow orifices is presented. The scientific instrument is designed to employ X-ray micro computed tomography (microCT) as a quantitative 3D measuring technique applied to custom designed, large-scale, orifice-type flow channels made from Polyether-ether-ketone (PEEK). The attenuation of the ionising electromagnetic radiation by the fluid under examination depends on its local density; the transmitted radiation through the cavitation volume is compared to the incident radiation, and combination of radiographies from sufficient number of angles leads to the reconstruction of attenuation coefficients versus the spatial position. This results to a 3D volume fraction distribution measurement of the developing multiphase flow. The experimental results obtained are compared against the high speed shadowgraph visualisation images obtained in an optically transparent nozzle with identical injection geometry; comparison between the temporal mean image and the microCT reconstruction shows excellent agreement. At the same time, the real 3D internal channel geometry (possibly eroded) has been measured and compared to the nominal manufacturing CAD drawing of the test nozzle.
Lunar Surface Systems Wet-Bath Design Evaluation
NASA Technical Reports Server (NTRS)
Thompson, Shelby; Szabo, Rich; Howard, Robert
2010-01-01
The goal of the current evaluation was to examine five different wet-bath architectural design concepts. The primary means of testing the concepts required participants to physically act-out a number of functional tasks (e.g., shaving, showering, changing clothes, maintenance) in order to give judgments on the affordance of the volume as based on the design concepts. Each of the concepts was designed in such a way that certain features were exploited - for example, a concept may have a large amount of internal stowage, but minimum amount of usable space to perform tasks. The results showed that the most preferred concept was one in which stowage and usable space were balanced. This concept allowed for a moderate amount of stowage with some suggested redesign, but would not preclude additional personal items such as clothing. This concept also allowed for a greater distance to be achieved between the toilet and the sink with minimum redesign, which was desirable. Therefore, the all-in-one (i.e., toilet, sink, and shower all occupying a single volume) wet-bath concept seemed to be a viable solution in which there is a minimal amount of overall volume available with certain lunar habitat configurations.
Umari, Paolo; Fossati, Nicola; Gandaglia, Giorgio; Pokorny, Morgan; De Groote, Ruben; Geurts, Nicolas; Goossens, Marijn; Schatterman, Peter; De Naeyer, Geert; Mottrie, Alexandre
2017-04-01
We report a comparative analysis of robotic assisted simple prostatectomy vs holmium laser enucleation of the prostate in patients who had benign prostatic hyperplasia with a large volume prostate (greater than 100 ml). A total of 81 patients underwent robotic assisted simple prostatectomy and 45 underwent holmium laser enucleation of the prostate in a 7-year period. Patients were preoperatively assessed with transrectal ultrasound and uroflowmetry. Functional parameters were assessed postoperatively during followup. Perioperative outcomes included operative time, postoperative hemoglobin, catheterization time and hospitalization. Complications were reported according to the Clavien-Dindo classification. Compared to the holmium laser enucleation group, patients treated with prostatectomy were significantly younger (median age 69 vs 74 years, p = 0.032) and less healthy (Charlson comorbidity index 2 or greater in 62% vs 29%, p = 0.0003), and had a lower rate of suprapubic catheterization (23% vs 42%, p = 0.028) and a higher preoperative I-PSS (International Prostate Symptom Score) (25 vs 21, p = 0.049). Both groups showed an improvement in the maximum flow rate (15 vs 11 ml per second, p = 0.7), and a significant reduction in post-void residual urine (-73 vs -100 ml, p = 0.4) and I-PSS (-20 vs -18, p = 0.8). Median operative time (105 vs 105 minutes, p = 0.9) and postoperative hemoglobin (13.2 vs 13.8 gm/dl, p = 0.08) were similar for robotic assisted prostatectomy and holmium laser enucleation, respectively. Median catheterization time (3 vs 2 days, p = 0.005) and median hospitalization (4 vs 2 days, p = 0.0001) were slightly shorter in the holmium laser group. Complication rates were similar with no Clavien grade greater than 3 in either group. Our results from a single center suggest comparable outcomes for robotic assisted simple prostatectomy and holmium laser enucleation of the prostate in patients with a large volume prostate. These findings require external validation at other high volume centers. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Large-Eddy Simulation of Internal Flow through Human Vocal Folds
NASA Astrophysics Data System (ADS)
Lasota, Martin; Šidlof, Petr
2018-06-01
The phonatory process occurs when air is expelled from the lungs through the glottis and the pressure drop causes flow-induced oscillations of the vocal folds. The flow fields created in phonation are highly unsteady and the coherent vortex structures are also generated. For accuracy it is essential to compute on humanlike computational domain and appropriate mathematical model. The work deals with numerical simulation of air flow within the space between plicae vocales and plicae vestibulares. In addition to the dynamic width of the rima glottidis, where the sound is generated, there are lateral ventriculus laryngis and sacculus laryngis included in the computational domain as well. The paper presents the results from OpenFOAM which are obtained with a large-eddy simulation using second-order finite volume discretization of incompressible Navier-Stokes equations. Large-eddy simulations with different subgrid scale models are executed on structured mesh. In these cases are used only the subgrid scale models which model turbulence via turbulent viscosity and Boussinesq approximation in subglottal and supraglottal area in larynx.
Tensor methodology and computational geometry in direct computational experiments in fluid mechanics
NASA Astrophysics Data System (ADS)
Degtyarev, Alexander; Khramushin, Vasily; Shichkina, Julia
2017-07-01
The paper considers a generalized functional and algorithmic construction of direct computational experiments in fluid dynamics. Notation of tensor mathematics is naturally embedded in the finite - element operation in the construction of numerical schemes. Large fluid particle, which have a finite size, its own weight, internal displacement and deformation is considered as an elementary computing object. Tensor representation of computational objects becomes strait linear and uniquely approximation of elementary volumes and fluid particles inside them. The proposed approach allows the use of explicit numerical scheme, which is an important condition for increasing the efficiency of the algorithms developed by numerical procedures with natural parallelism. It is shown that advantages of the proposed approach are achieved among them by considering representation of large particles of a continuous medium motion in dual coordinate systems and computing operations in the projections of these two coordinate systems with direct and inverse transformations. So new method for mathematical representation and synthesis of computational experiment based on large particle method is proposed.
Technologies for imaging neural activity in large volumes
Ji, Na; Freeman, Jeremy; Smith, Spencer L.
2017-01-01
Neural circuitry has evolved to form distributed networks that act dynamically across large volumes. Collecting data from individual planes, conventional microscopy cannot sample circuitry across large volumes at the temporal resolution relevant to neural circuit function and behaviors. Here, we review emerging technologies for rapid volume imaging of neural circuitry. We focus on two critical challenges: the inertia of optical systems, which limits image speed, and aberrations, which restrict the image volume. Optical sampling time must be long enough to ensure high-fidelity measurements, but optimized sampling strategies and point spread function engineering can facilitate rapid volume imaging of neural activity within this constraint. We also discuss new computational strategies for the processing and analysis of volume imaging data of increasing size and complexity. Together, optical and computational advances are providing a broader view of neural circuit dynamics, and help elucidate how brain regions work in concert to support behavior. PMID:27571194
Equation of state of MgSiO3 post-perovskite
NASA Astrophysics Data System (ADS)
Sakai, T.; Dekura, H.; Hirao, N.
2014-12-01
Super-Earths which have a few times of the Earth's mass have been found in the extra solar system one after another. MgSiO3 post-perovskite (PPv) is an abundant silicate phase in such huge terrestrial planet's mantle (Tsuchiya and Tsuchiya, 2011). For preliminary internal structure estimation, the mass-radius relation was used (Zeng et al. 2013). Above 120 GPa, the mass-radius relation for MgSiO3 end-member is calculated from the equations of state (EoS) of PPv. Although the pressure condition of super-Earth's mantle reaches several hundreds GPa, the previously reported EoSs of PPv by the diamond anvil cell (DAC) experiment were limited up to around 150 GPa. These EoSs were extrapolated to multi-megabar condition for the calculation of the mass-radius relation. The large extrapolation yields uncertainty. The direct determination of the compression behavior of PPv at multi-megabar pressure is, therefore, important to understand the super-Earth's interior. Here we report PPv EoS up to 275 GPa based on DAC experiment and up to 1 TPa and 6000 K by ab initio calculation based on the density-functional theory in the same manner as Tsuchiya et al. (2004). Volume data were obtained up to 275 GPa by the DAC experiment and fitted to the third order Birch-Murnaghan EoS and the Vinet EoS. The experimental EoS agrees excellently with the calculated ab initio volume data within 0.5 % up to 500 GPa and 3000 K. The volume differences between the present result and those calculated by Caracas and Cohen (2008) were about 2.0-2.6 % in pressure range of 100-500 GPa at room temperature, while the volume differences were only 1 % with respect to the EoS based on shock experiment data (Mosenfelder et al. 2009) in the same pressure range. The present EoS shows internal consistency among DAC, shock and ab initio data up to 500 GPa within 1% in volume. Our new EoS provides more precise mass-radius relation for MgSiO3 end-member.
International labor migration and the family: some observations from Indonesia.
Hugo, G
1995-01-01
This article addresses two dimensions of the complex interrelationship between the family and international labor migration in Indonesia: the role of the family in influencing labor movements out of Indonesia; and the consequences of this movement on family well-being, structure, and functioning. Research on this topic in Indonesia is highly limited due mainly to the recency of large scale international labor migration, inadequate data collection systems, a high incidence of undocumented migration, and failure of available research to be sensitive to family related issues. Against a rapidly changing economic and social situation, two major overlapping systems of migration have developed. The official system is focused strongly on the Middle East (although other Asian destinations are increasing in significance) and is dominated by female migrants. The undocumented system is much larger in volume, is focused upon Malaysia, involves more males than females, and is becoming permanent in some cases. The role, status, and experiences of women migrants in relation to their families (decision making, networks, remittances) are discussed with recommendations for other areas needing further research attention.
NASA Astrophysics Data System (ADS)
Krafcik, Matthew J.; Erk, Kendra A.
Superabsorbent hydrogel particles show promise as internal curing agents for high performance concrete (HPC). These gels can absorb and release large volumes of water and offer a solution to the problem of self-dessication in HPC. However, the gels are sensitive to ions naturally present in concrete. This research connects swelling behavior with gel-ion interactions to optimize hydrogel performance for internal curing, reducing the chance of early-age cracking and increasing the durability of HPC. Four different hydrogels of poly(sodium-acrylate acrylamide) are synthesized and characterized with swelling tests in different salt solutions. Depending on solution pH, ionic character, and gel composition, diffrerent swelling behaviors are observed. As weight percent of acrylic acid increases, gels demonstrate higher swelling ratios in reverse osmosis water, but showed substantially decreased swelling when aqueous cations are present. Additionally, in multivalent cation solutions, overshoot peaks are present, whereby the gels have a peak swelling ratio but then deswell. Multivalent cations interact with deprotonated carboxylic acid groups, constricting the gel and expelling water. Mortar containing hydrogels showed reduced autogenous shrinkage and increased relative humidity.
2002-05-13
Mount • Install Large Capacity Ammo Container On Mount • Add Actuators And Resolvers For Laying OCSW Independent Of Main Gun t ti f t ti...FY07 FY08 FY09 FY10 FY11 FY12 4 5 6 SI Prod Block II (2K FLIR,Dual Feed, CPU Upgrade, AP Enhancements, MEMS) IOT &E LFT&E LUT...PQT Fielding (T) SDD C&TD Production LRIP SDD Prototypes Prototype Build BDENET MS B FRP MS C LRIP FCS S D D P ro to ty p es IOTE SD LRIP OCSW
NASA Astrophysics Data System (ADS)
Maurer, Frans H. J.; Arza, Carlos R.
2015-06-01
The influence of dispersion and interaction of Graphene Oxide (GO) in semicrystalline Polyhydroxy butyrate (PHB) and glassy amorphous Poly(tBP-oda) is explored by Positron Annihilation Lifetime Spectroscopy (PALS). The ortho-Positronium lifetimes which represent the main free volume hole size of both polymers are mainly affected by the large differences in internal stresses built up by the shrinkage of the polymers during their preparation, restricted by the platelet structure of GO. The ortho-Positronium intensities, which represent the ortho-Positronium formation probabilities, suggest a strong dependency of on the dispersion of the nano-particles and their aspect ratio.
Book review: Geomagnetism of baked clays and recent sediments
Mankinen, Edward A.
1984-01-01
This book is an outgrowth of the symposium entitled “Time Scales of Geomagnetic Secular Variations,” which was held at the 4th Assembly of the International Association of Geomagnetism and Aeronomy (Edinburgh, U.K., August 1981). The volume includes many of the papers presented, which described paleomagnetic results from both archeologic materials and Holocene geologic deposits, as well as contributions solicited from other researchers in the fields of archeomagnetism and paleomagnetism. In a remarkably short time after the conclusion of the symposium the editors were able to elicit, edit, and assemble a large body of material from 40 individuals into a thoughtful, wellorganized product.
Method and apparatus for extracting tritium and preparing radioactive waste for disposal
Heung, Leung K.
1994-01-01
Apparatus for heating an object such as a nuclear target bundle to release and recover hydrogen and contain the disposable residue for disposal. The apparatus comprises an inverted furnace, a sleeve/crucible assembly for holding and enclosing the bundle, conveying equipment for placing the sleeve onto the crucible and loading the bundle into the sleeve/crucible, a lift for raising the enclosed bundle into the furnace, and hydrogen recovery equipment including a trap and strippers, all housed in a containment having negative internal pressure. The crucible/sleeve assembly has an internal volume that is sufficient to enclose and hold the bundle before heating; the crucible's internal volume is sufficient by itself to hold and enclose the bundle's volume after heating. The crucible can then be covered and disposed of; the sleeve, on the other hand, can be reused.
A method to directly measure maximum volume of fish stomachs or digestive tracts
Burley, C.C.; Vigg, S.
1989-01-01
A new method for measuring maximum stomach or digestive tract volume of fish incorporates air injection at constant pressure with water displacement to measure directly the internal volume of a stomach or analogous structure. The method was tested with coho salmon, Oncorhynchus kisutch (Walbaum), which has a true stomach, and northern squawfish, Ptychocheilus oregonensis(Richardson), which has a modified foregut as a functional analogue. Both species were collected during July-October 1987 from the Columbia River, U.S.A. Relationships between fish weight (= volume) and maximum volume of the digestive organ were best fitted for coho salmon by an allometric model and for northern squawfish by an exponential model. Least squares regression analysis of individual measurements showed less variability in the volume of coho salmon stomachs (R2= 0.85) than in the total digestive tracts (R2= 0.55) and foreguts (R2= 0.61) of northern squawfish, relative to fish size. Compared to previous methods, the new technique has the advantage of accurately measuring the internal volume of a wide range of digestive organ shapes and sizes.
NASA Technical Reports Server (NTRS)
Kennedy, Kriss J.; Lewis, Ruthan; Toups, Larry; Howard, Robert; Whitmire, Alexandra; Smitherman, David; Howe, Scott
2016-01-01
As our human spaceflight missions change as we reach towards Mars, the risk of an adverse behavioral outcome increases, and requirements for crew health, safety, and performance, and the internal architecture, will need to change to accommodate unprecedented mission demands. Evidence shows that architectural arrangement and habitability elements impact behavior. Net habitable volume is the volume available to the crew after accounting for elements that decrease the functional volume of the spacecraft. Determination of minimum acceptable net habitable volume and associated architectural design elements, as mission duration and environment varies, is key to enabling, maintaining, andor enhancing human performance and psychological and behavioral health. Current NASA efforts to derive minimum acceptable net habitable volumes and study the interaction of covariates and stressors, such as sensory stimulation, communication, autonomy, and privacy, and application to internal architecture design layouts, attributes, and use of advanced accommodations will be presented. Furthermore, implications of crew adaptation to available volume as they transfer from Earth accommodations, to deep space travel, to planetary surface habitats, and return, will be discussed.
Jain, Anil Kumar; Khan, Asma M
2012-09-01
: The potential for fluid overload in large-volume liposuction is a source of serious concern. Fluid management in these patients is controversial and governed by various formulas that have been advanced by many authors. Basically, it is the ratio of what goes into the patient and what comes out. Central venous pressure has been used to monitor fluid therapy. Dynamic parameters, such as stroke volume and pulse pressure variation, are better predictors of volume responsiveness and are superior to static indicators, such as central venous pressure and pulmonary capillary wedge pressure. Stroke volume variation was used in this study to guide fluid resuscitation and compared with one guided by an intraoperative fluid ratio of 1.2 (i.e., Rohrich formula). : Stroke volume variation was used as a guide for intraoperative fluid administration in 15 patients subjected to large-volume liposuction. In another 15 patients, fluid resuscitation was guided by an intraoperative fluid ratio of 1.2. The amounts of intravenous fluid administered in the groups were compared. : The mean amount of fluid infused was 561 ± 181 ml in the stroke volume variation group and 2383 ± 1208 ml in the intraoperative fluid ratio group. The intraoperative fluid ratio when calculated for the stroke volume variation group was 0.936 ± 0.084. All patients maintained hemodynamic parameters (heart rate and systolic, diastolic, and mean blood pressure). Renal and metabolic indices remained within normal limits. : Stroke volume variation-guided fluid application could result in an appropriate amount of intravenous fluid use in patients undergoing large-volume liposuction. : Therapeutic, II.
Yu, Teresa; Korgaonkar, Mayuresh S; Grieve, Stuart M
2017-04-01
This study examined patterns of cerebellar volumetric gray matter (GM) loss across the adult lifespan in a large cross-sectional sample. Four hundred and seventy-nine healthy participants (age range: 7-86 years) were drawn from the Brain Resource International Database who provided T1-weighted MRI scans. The spatially unbiased infratentorial template (SUIT) toolbox in SPM8 was used for normalisation of the cerebellum structures. Global volumetric and voxel-based morphometry analyses were performed to evaluate age-associated trends and gender-specific age-patterns. Global cerebellar GM shows a cross-sectional reduction with advancing age of 2.5 % per decade-approximately half the rate seen in the whole brain. The male cerebellum is larger with a lower percentage of GM, however, after controlling for total brain volume, no gender difference was detected. Analysis of age-related changes in GM volume revealed large bilateral clusters involving the vermis and cerebellar crus where regional loss occurred at nearly twice the average cerebellar rate. No gender-specific patterns were detected. These data confirm that regionally specific GM loss occurs in the cerebellum with age, and form a solid base for further investigation to find functional correlates for this global and focal loss.
C. John Ralph; Terrell D. Rich
2005-01-01
These two volumes contain in part papers presented at the Third International Partners in Flight Conference: A Workshop on Bird Conservation Implementation and Integration, which was held 20-24 March 2002 at the Asilomar Conference Center in Monterey, California. The conference gathered together researchers, educators, foresters, monitoring specialists, planners, and...
ERIC Educational Resources Information Center
Nakahara, Tadao, Ed.; Koyama, Masataka, Ed.
The fourth volume of the 24th annual conference of the International Group for the Psychology of Mathematics Education contains full research report papers. Papers include: (1) "What are essential to apply the 'discovery' function of proof in lower secondary school mathematics?" (Mikio Miyazaki); (2) "The anatomy of an 'open' mathematics lesson"…
Development and Experimental Application of International Affairs Indicators. Volume A
1974-06-01
DEVELOPMENT ’^EXPERIMENTAL APPttcATION OF INTERNATIONAL AFFAIRS INDICATORS Volume A Final Report e June 1974 US I Sponsored by: Defense Advanced...intelligence communities were designed, techniques for estimating the future were developed and tested, and the techniques and indicators were applied to the...past year’s effort is that the intelligence community has become increasingly aware of the potential use- fulness of quantitative indicators. The
ERIC Educational Resources Information Center
Rust, Val D., Ed.; Dalin, Per, Ed.
This book is an outgrowth of an international seminar held in Bali, Indonesia in 1986 entitled "Improving the Quality of Teaching in the Developing World: Alternative Models." The book contains essays written by 20 authors and coauthors from 12 different countries and is divided into five sections, plus a preface. The focus of section 1,…
ERIC Educational Resources Information Center
Hruday, Connie; And Others
This document is designed to assist the Council of Educational Facility Planners International (CEFP/I) in planning for the establishment of an information system for its members and other stakeholders who need information on educational facilities. The report focuses on the major activities to be accomplished and the issues to be considered when…
ERIC Educational Resources Information Center
Pateman, Neil A., Ed; Dougherty, Barbara J., Ed.; Zilliox, Joseph T., Ed.
2003-01-01
This volume of the 27th International Group for the Psychology of Mathematics Education Conference includes the following research reports: (1) Improving Decimal Number Conception by Transfer from Fractions to Decimals (Irita Peled and Juhaina Awawdy Shahbari); (2) The Development of Student Teachers' Efficacy Beliefs in Mathematics during…
ERIC Educational Resources Information Center
Hoines, Marit Johnsen, Ed.;
2004-01-01
This document contains the third volume of the proceedings of the 28th Annual Conference of the International Group for the Psychology of Mathematics. Conference presentations are centered around the theme "Inclusion and Diversity". A total of 65 research reports are presented here: (1) A Teacher's Model of Students Algebraic Thinking…
ERIC Educational Resources Information Center
Chick, Helen L., Ed.; Vincent, Jill L., Ed.
2005-01-01
The third volume of the 29th annual conference of the International Group for the Psychology of Mathematics Education contains full research report papers. Papers include: (1) Students' Use of ICT Tools: Choices and Reasons (Anne Berit Fuglestad); (2) Interaction of Modalities in Cabri: A Case Study (Fulvia Furinghetti, Francesca Morselli, and…
ERIC Educational Resources Information Center
van den Heuvel-Panhuizen, Marja, Ed.
This document contains the proceedings of the 25th annual Conference of the International Group for the Psychology of Mathematics Education (PME). It features plenary lectures, research forums, discussion groups, working sessions, short oral communications, and poster presentations. Papers in Volume 1 include: (1) "The P in PME: Progress and…
ERIC Educational Resources Information Center
Franco, Robert W., Ed.; Shimabukuro, James N., Ed.
Part of a four-volume set in which community college educators discuss their efforts to internationalize the educational experience of the students and communities they serve, volume I in this series highlights seven different but easily integrated strategies for adding an Asian-Pacific emphasis to the curriculum. Volume I includes: (1)…
ERIC Educational Resources Information Center
Corson, David, Ed.; Lawton, Stephen B., Ed.
These two volumes comprise the proceedings of a conference on links between education and work and the power relationships in the wider culture and in its social order. Each volume begins with a "Foreword" (Ronald C. Morrison), "Preface" (Arthur Kruger), "Introduction" (David Corson), and author notes. Volume I…
NASA Astrophysics Data System (ADS)
Plaksina, Tatyana; Kanfar, Mohammed
2017-11-01
With growing interest in commercial projects involving industrial volume CO2 sequestration, a concern about proper containment and control over the gas plume becomes particularly prominent. In this study, we explore the potential of using a typical coastal geopressured hot saline aquifer for two commercial purposes. The first purpose is to harvest geothermal heat of the aquifer for electricity generation and/or direct use and the second one is to utilize the same rock volume for safe and controlled CO2 sequestration without interruption of heat production. To achieve these goals, we devised and economically evaluated a scheme that recovers operational and capital costs within first 4 years and yields positive internal rate of return of about 15% at the end of the operations. Using our strategic design of well placement and operational scheduling, we were able to achieve in our numerical simulation study the following results. First, the hot water production rates allowed to run a 30 MW organic Rankine cycle plant for 20 years. Second, during the last 10 years of operation we managed to inject into the same reservoir (volume of 0.8 x 109 m3) approximately 10 million ton of the supercritical gas. Third, decades of numerical monitoring the plume after the end of the operations showed that this large volume of CO2 is securely sequestrated inside the reservoir without compromising the caprock integrity.
Kaufmann, Royi; Yadid, Itamar; Goldfarb, Daniella
2013-05-01
Rapid freeze quench electron paramagnetic resonance (RFQ)-EPR is a method for trapping short lived intermediates in chemical reactions and subjecting them to EPR spectroscopy investigation for their characterization. Two (or more) reacting components are mixed at room temperature and after some delay the mixture is sprayed into a cold trap and transferred into the EPR tube. A major caveat in using commercial RFQ-EPR for high field EPR applications is the relatively large amount of sample needed for each time point, a major part of which is wasted as the dead volume of the instrument. The small sample volume (∼2μl) needed for high field EPR spectrometers, such as W-band (∼3.5T, 95GHz), that use cavities calls for the development of a microfluidic based RFQ-EPR apparatus. This is particularly important for biological applications because of the difficulties often encountered in producing large amounts of intrinsically paramagnetic proteins and spin labeled nucleic acid and proteins. Here we describe a dedicated microfluidic based RFQ-EPR apparatus suitable for small volume samples in the range of a few μl. The device is based on a previously published microfluidic mixer and features a new ejection mechanism and a novel cold trap that allows collection of a series of different time points in one continuous experiment. The reduction of a nitroxide radical with dithionite, employing the signal of Mn(2+) as an internal standard was used to demonstrate the performance of the microfluidic RFQ apparatus. Copyright © 2013 Elsevier Inc. All rights reserved.
The role of volatiles in magma chamber dynamics.
Huppert, Herbert E; Woods, Andrew W
2002-12-05
Many andesitic volcanoes exhibit effusive eruption activity, with magma volumes as large as 10(7)-10(9) m(3) erupted at rates of 1-10 m(3) x s(-1) over periods of years or decades. During such eruptions, many complex cycles in eruption rates have been observed, with periods ranging from hours to years. Longer-term trends have also been observed, and are thought to be associated with the continuing recharge of magma from deep in the crust and with waning of overpressure in the magma reservoir. Here we present a model which incorporates effects due to compressibility of gas in magma. We show that the eruption duration and volume of erupted magma may increase by up to two orders of magnitude if the stored internal energy associated with dissolved volatiles can be released into the magma chamber. This mechanism would be favoured in shallow chambers or volatile-rich magmas and the cooling of magma by country rock may enhance this release of energy, leading to substantial increases in eruption rate and duration.
Ammann, Elizabeth C. B.; Lynch, Victoria H.
1967-01-01
The oxygen production of a photosynthetic gas exchanger containing Chlorella pyrenoidosa (1% packed cell volume) was measured when various concentrations of carbon dioxide were present within the culture unit. The internal carbon dioxide concentrations were obtained by manipulating the entrance gas concentration and the flow rate. Carbon dioxide percentages were monitored by means of electrodes placed directly in the nutrient medium. The concentration of carbon dioxide in the nutrient medium which produced maximal photosynthesis was in the range of 1.5 to 2.5% by volume. Results were unaffected by either the level of carbon dioxide in the entrance gas or the rate of gas flow. Entrance gases containing 2% carbon dioxide flowing at 320 ml/min, 3% carbon dioxide at 135 ml/min, and 4% carbon dioxide at 55 ml/min yielded optimal carbon dioxide concentrations in the particular unit studied. By using carbon dioxide electrodes implanted directly in the gas exchanger to optimize the carbon dioxide concentration throughout the culture medium, it should be possible to design more efficient large-scale units. PMID:4382391
Self-gated golden-angle spiral 4D flow MRI.
Bastkowski, Rene; Weiss, Kilian; Maintz, David; Giese, Daniel
2018-01-17
The acquisition of 4D flow magnetic resonance imaging (MRI) in cardiovascular applications has recently made large progress toward clinical feasibility. The need for simultaneous compensation of cardiac and breathing motion still poses a challenge for widespread clinical use. Especially, breathing motion, addressed by gating approaches, can lead to unpredictable and long scan times. The current work proposes a time-efficient self-gated 4D flow sequence that exploits up to 100% of the acquired data and operates at a predictable scan time. A self-gated golden-angle spiral 4D flow sequence was implemented and tested in 10 volunteers. Data were retrospectively binned into respiratory and cardiac states and reconstructed using a conjugate-gradient sensitivity encoding reconstruction. Net flow curves, stroke volumes, and peak flow in the aorta were evaluated and compared to a conventional Cartesian 4D flow sequence. Additionally, flow quantities reconstructed from 50% to 100% of the self-gated 4D flow data were compared. Self-gating signals for respiratory and cardiac motion were extracted for all volunteers. Flow quantities were in agreement with the standard Cartesian scan. Mean differences in stroke volumes and peak flow of 7.6 ± 11.5 and 4.0 ± 79.9 mL/s were obtained, respectively. By retrospectively increasing breathing navigator efficiency while decreasing acquisition times (15:06-07:33 minutes), 50% of the acquired data were sufficient to measure stroke volumes with errors under 9.6 mL. The feasibility to acquire respiratory and cardiac self-gated 4D flow data at a predictable scan time was demonstrated. Magn Reson Med, 2018. © 2018 International Society for Magnetic Resonance in Medicine. © 2018 International Society for Magnetic Resonance in Medicine.
International Radiation Monitoring and Information System (IRMIS)
NASA Astrophysics Data System (ADS)
Mukhopadhyay, Sanjoy; Baciu, Florian; Stowisek, Jan; Saluja, Gurdeep; Kenny, Patrick; Albinet, Franck
2017-09-01
This article describes the International Radiation Monitoring Information System (IRMIS) which was developed by the International Atomic Energy Agency (IAEA) with the goal to provide Competent Authorities, the IAEA and other international organizations with a client server based web application to share and visualize large quantities of radiation monitoring data. The data maps the areas of potential impact that can assist countries to take appropriate protective actions in an emergency. Ever since the Chernobyl nuclear power plant accident in April of 19861 European Community (EC) has worked towards collecting routine environmental radiological monitoring data from national networked monitoring systems. European Radiological Data Exchange Platform (EURDEP) was created in 19952 to that end - to provide radiation monitoring data from most European countries reported in nearly real-time. During the response operations for the Fukushima Dai-ichi nuclear power plant accident (March 2011) the IAEA Incident and Emergency Centre (IEC) managed, harmonized and shared the large amount of data that was being generated from different organizations. This task underscored the need for a system which allows sharing large volumes of radiation monitoring data in an emergency. In 2014 EURDEP started the submission of the European radiological data to the International Radiation Monitoring Information System (IRMIS) as a European Regional HUB for IRMIS. IRMIS supports the implementation of the Convention on Early Notification of a Nuclear Accident by providing a web application for the reporting, sharing, visualizing and analysing of large quantities of environmental radiation monitoring data during nuclear or radiological emergencies. IRMIS is not an early warning system that automatically reports when there are significant deviations in radiation levels or when values are detected above certain levels. However, the configuration of the visualization features offered by IRMIS may help Member States to determine where elevated gamma dose rate measurements during a radiological or nuclear emergency indicate that actions to protect the public are necessary. The data can be used to assist emergency responders determine where and when to take necessary actions to protect the public. This new web online tool supports the IAEA's Unified System for Information Exchange in Incidents and Emergencies (USIE)3, an online tool where competent authorities can access information about all emergency situations, ranging from a lost radioactive source to a full-scale nuclear emergency.
Liposuction: Anaesthesia challenges
Sood, Jayashree; Jayaraman, Lakshmi; Sethi, Nitin
2011-01-01
Liposuction is one of the most popular treatment modalities in aesthetic surgery with certain unique anaesthetic considerations. Liposuction is often performed as an office procedure. There are four main types of liposuction techniques based on the volume of infiltration or wetting solution injected, viz dry, wet, superwet, and tumescent technique. The tumescent technique is one of the most common liposuction techniques in which large volumes of dilute local anaesthetic (wetting solution) are injected into the fat to facilitate anaesthesia and decrease blood loss. The amount of lignocaine injected may be very large, approximately 35-55 mg/kg, raising concerns regarding local anaesthetic toxicity. Liposuction can be of two types according to the volume of solution aspirated: High volume (>4,000 ml aspirated) or low volume (<4,000 ml aspirated). While small volume liposuction may be done under local/monitored anaesthesia care, large-volume liposuction requires general anaesthesia. As a large volume of wetting solution is injected into the subcutaneous tissue, the intraoperative fluid management has to be carefully titrated along with haemodynamic monitoring and temperature control. Assessment of blood loss is difficult, as it is mixed with the aspirated fat. Since most obese patients opt for liposuction as a quick method to lose weight, all concerns related to obesity need to be addressed in a preoperative evaluation. PMID:21808392
Martín-Vega, Daniel; Simonsen, Thomas J; Hall, Martin J R
2017-05-01
Metamorphosis of cyclorrhaphous flies takes place inside a barrel-like puparium, formed by the shrinking, hardening and darkening of the third-instar larval cuticle. The opacity of this structure hampers the visualization of the morphological changes occurring inside and therefore a full understanding of the metamorphosis process. Here, we use micro-computed tomography (micro-CT) to describe the internal morphological changes that occur during metamorphosis of the blow fly, Calliphora vicina Robineau-Desvoidy 1830 (Diptera: Calliphoridae) at a greater temporal resolution than anything hitherto published. The morphological changes were documented at 10% intervals of the total intra-puparial period, and down to 2.5% intervals during the first 20% interval, when the most dramatic morphological changes occur. Moreover, the development of an internal gas bubble, which plays an essential role during early metamorphosis, was further investigated with X-ray images and micro-CT virtual sections. The origin of this gas bubble has been largely unknown, but micro-CT virtual sections show that it is connected to one of the main tracheal trunks. Micro-CT virtual sections also provided enough resolution for determining the completion of the larval-pupal and pupal-adult apolyses, thus enabling an accurate timing of the different intra-puparial life stages. The prepupal, pupal, and pharate adult stages last for 7.5%, 22.5%, and 70% of the total intra-puparial development, respectively. Furthermore, we provide for the first time quantitative data on the development of two organ systems of the blow fly: the alimentary canal and the indirect flight muscles. There is a significant and negative correlation between the volume of the indirect flight muscles and the pre-helicoidal region of the midgut during metamorphosis. The latter occupies a large portion of the thorax during the pupal stage but narrows progressively as the indirect flight muscles increase in volume during the development of the pharate adult. © 2017 The Authors Journal of Morphology Published by Wiley Periodicals, Inc.
Simonsen, Thomas J.; Hall, Martin J. R.
2017-01-01
Abstract Metamorphosis of cyclorrhaphous flies takes place inside a barrel‐like puparium, formed by the shrinking, hardening and darkening of the third‐instar larval cuticle. The opacity of this structure hampers the visualization of the morphological changes occurring inside and therefore a full understanding of the metamorphosis process. Here, we use micro‐computed tomography (micro‐CT) to describe the internal morphological changes that occur during metamorphosis of the blow fly, Calliphora vicina Robineau‐Desvoidy 1830 (Diptera: Calliphoridae) at a greater temporal resolution than anything hitherto published. The morphological changes were documented at 10% intervals of the total intra‐puparial period, and down to 2.5% intervals during the first 20% interval, when the most dramatic morphological changes occur. Moreover, the development of an internal gas bubble, which plays an essential role during early metamorphosis, was further investigated with X‐ray images and micro‐CT virtual sections. The origin of this gas bubble has been largely unknown, but micro‐CT virtual sections show that it is connected to one of the main tracheal trunks. Micro‐CT virtual sections also provided enough resolution for determining the completion of the larval‐pupal and pupal‐adult apolyses, thus enabling an accurate timing of the different intra‐puparial life stages. The prepupal, pupal, and pharate adult stages last for 7.5%, 22.5%, and 70% of the total intra‐puparial development, respectively. Furthermore, we provide for the first time quantitative data on the development of two organ systems of the blow fly: the alimentary canal and the indirect flight muscles. There is a significant and negative correlation between the volume of the indirect flight muscles and the pre‐helicoidal region of the midgut during metamorphosis. The latter occupies a large portion of the thorax during the pupal stage but narrows progressively as the indirect flight muscles increase in volume during the development of the pharate adult. PMID:28182298
Transportation-markings database : international marine aids to navigation. Volume 1, parts C and D
DOT National Transportation Integrated Search
1988-01-01
This monograph is the second edition of Volume I, Parts C and D of what was formerly termed Transportation Markings: A Study in Communication. The first edition of Volume I also included Parts A and B. The original edition was published by University...
EVALUATION OF VAPOR EQUILIBRATION AND IMPACT OF PURGE VOLUME ON SOIL-GAS SAMPLING RESULTS
Sequential sampling was utilized at the Raymark Superfund site to evaluate attainment of vapor equilibration and the impact of purge volume on soil-gas sample results. A simple mass-balance equation indicates that removal of three to five internal volumes of a sample system shou...
Lauf, P K; Adragna, N C
1996-10-01
Swelling-induced human erythrocyte K-Cl cotransport is membrane potential independent and capable of uphill transport. However, a complete thermodynamic analysis of basal and stimulated K-Cl cotransport, at constant cell volume, is missing. This study was performed in low K sheep red blood cells before and after reducing cellular free Mg into the nanomolar range with the divalent cation ionophore A23187 and a chelator, an intervention known to stimulate K-Cl cotransport. The anion exchange inhibitor 4,4'diisothiocyanato-2,2'disulfonic stilbene was used to clamp intracellular pH and Cl or NO3 concentrations. Cell volume was maintained constant as external and internal pH differed by more than two units. K-Cl cotransport was calculated from the K effluxes and Rb (as K congener) influxes measured in Cl and NO3, at constant internal K and external anions, and variable concentrations of extracellular Rb and internal anions, respectively. The external Rb concentration at which net K-Cl cotransport is zero was defined as flux reversal point which changed with internal pH and hence Cl. Plots of the ratio of external Rb concentrations corresponding to the flux reversal points and the internal K concentration versus the ratio of the internal and external Cl concentrations (i.e., the Donnan ratio of the transported ions) yielded slopes near unity for both control and low internal Mg cells. Thus, basal as well as low internal Mg-stimulated net K-Cl cotransport depends on the electrochemical potential gradient of KCl.
1996-01-01
Swelling-induced human erythrocyte K-Cl cotransport is membrane potential independent and capable of uphill transport. However, a complete thermodynamic analysis of basal and stimulated K-Cl cotransport, at constant cell volume, is missing. This study was performed in low K sheep red blood cells before and after reducing cellular free Mg into the nanomolar range with the divalent cation ionophore A23187 and a chelator, an intervention known to stimulate K- Cl cotransport. The anion exchange inhibitor 4,4'diisothiocyanato- 2,2'disulfonic stilbene was used to clamp intracellular pH and Cl or NO3 concentrations. Cell volume was maintained constant as external and internal pH differed by more than two units. K-Cl cotransport was calculated from the K effluxes and Rb (as K congener) influxes measured in Cl and NO3, at constant internal K and external anions, and variable concentrations of extracellular Rb and internal anions, respectively. The external Rb concentration at which net K-Cl cotransport is zero was defined as flux reversal point which changed with internal pH and hence Cl. Plots of the ratio of external Rb concentrations corresponding to the flux reversal points and the internal K concentration versus the ratio of the internal and external Cl concentrations (i.e., the Donnan ratio of the transported ions) yielded slopes near unity for both control and low internal Mg cells. Thus, basal as well as low internal Mg-stimulated net K-Cl cotransport depends on the electrochemical potential gradient of KCl. PMID:8894982
International Space Station (ISS) Water Transfer Hardware Logistics
NASA Technical Reports Server (NTRS)
Shkedi, Brienne D.
2006-01-01
Water transferred from the Space Shuttle to the International Space Station (ISS) is generated as a by-product from the Shuttle fuel cells, and is generally preferred over the Progress which has to launch water from the ground. However, launch mass and volume are still required for the transfer and storage hardware. Some of these up-mass requirements have been reduced since ISS assembly began due to changes in the storage hardware (CWC). This paper analyzes the launch mass and volume required to transfer water from the Shuttle and analyzes the up-mass savings due to modifications in the CWC. Suggestions for improving the launch mass and volume are also provided.
NASA Astrophysics Data System (ADS)
Del Gobbo, Costanza; Colucci, Renato R.; Forte, Emanuele; Triglav Čekada, Michaela; Zorn, Matija
2016-08-01
It is well known that small glaciers of mid latitudes and especially those located at low altitude respond suddenly to climate changes both on local and global scale. For this reason their monitoring as well as evaluation of their extension and volume is essential. We present a ground penetrating radar (GPR) dataset acquired on September 23 and 24, 2013 on the Triglav glacier to identify layers with different characteristics (snow, firn, ice, debris) within the glacier and to define the extension and volume of the actual ice. Computing integrated and interpolated 3D using the whole GPR dataset, we estimate that at the moment of data acquisition the ice area was 3800 m2 and the ice volume 7400 m3. Its average thickness was 1.95 m while its maximum thickness was slightly more than 5 m. Here we compare the results with a previous GPR survey acquired in 2000. A critical review of the historical data to find the general trend and to forecast a possible evolution is also presented. Between 2000 and 2013, we observed relevant changes in the internal distribution of the different units (snow, firn, ice) and the ice volume reduced from about 35,000 m3 to about 7400 m3. Such result can be achieved only using multiple GPR surveys, which allow not only to assess the volume occupied by a glacial body, but also to image its internal structure and the actual ice volume. In fact, by applying one of the widely used empirical volume-area relations to infer the geometrical parameters of the glacier, a relevant underestimation of ice-loss would be achieved.
NASA Astrophysics Data System (ADS)
Reynolds, Steven; Bucur, Adriana; Port, Michael; Alizadeh, Tooba; Kazan, Samira M.; Tozer, Gillian M.; Paley, Martyn N. J.
2014-02-01
Over recent years hyperpolarization by dissolution dynamic nuclear polarization has become an established technique for studying metabolism in vivo in animal models. Temporal signal plots obtained from the injected metabolite and daughter products, e.g. pyruvate and lactate, can be fitted to compartmental models to estimate kinetic rate constants. Modeling and physiological parameter estimation can be made more robust by consistent and reproducible injections through automation. An injection system previously developed by us was limited in the injectable volume to between 0.6 and 2.4 ml and injection was delayed due to a required syringe filling step. An improved MR-compatible injector system has been developed that measures the pH of injected substrate, uses flow control to reduce dead volume within the injection cannula and can be operated over a larger volume range. The delay time to injection has been minimized by removing the syringe filling step by use of a peristaltic pump. For 100 μl to 10.000 ml, the volume range typically used for mice to rabbits, the average delivered volume was 97.8% of the demand volume. The standard deviation of delivered volumes was 7 μl for 100 μl and 20 μl for 10.000 ml demand volumes (mean S.D. was 9 ul in this range). In three repeat injections through a fixed 0.96 mm O.D. tube the coefficient of variation for the area under the curve was 2%. For in vivo injections of hyperpolarized pyruvate in tumor-bearing rats, signal was first detected in the input femoral vein cannula at 3-4 s post-injection trigger signal and at 9-12 s in tumor tissue. The pH of the injected pyruvate was 7.1 ± 0.3 (mean ± S.D., n = 10). For small injection volumes, e.g. less than 100 μl, the internal diameter of the tubing contained within the peristaltic pump could be reduced to improve accuracy. Larger injection volumes are limited only by the size of the receiving vessel connected to the pump.
Frictionless bead packs have macroscopic friction, but no dilatancy.
Peyneau, Pierre-Emmanuel; Roux, Jean-Noël
2008-07-01
The statement of the title is shown by numerical simulation of homogeneously sheared assemblies of frictionless, nearly rigid beads in the quasistatic limit. Results coincide for steady flows at constant shear rate gamma[over ] in the limit of small gamma[over ] and static approaches, in which packings are equilibrated under growing deviator stresses. The internal friction angle phi , equal to 5.76 degrees +/-0.22 degrees in simple shear, is independent of average pressure P in the rigid limit and stems from the ability of stable frictionless contact networks to form stress-induced anisotropic fabrics. No enduring strain localization is observed. Dissipation at the macroscopic level results from repeated network rearrangements, similar to the effective friction of a frictionless slider on a bumpy surface. Solid fraction Phi remains equal to the random close packing value approximately 0.64 in slowly or statically sheared systems. Fluctuations of stresses and volume are observed to regress in the large system limit. Defining the inertial number as I=gamma radical m/(aP), with m the grain mass and a its diameter, both internal friction coefficient mu*=tan phi and volume 1/Phi increase as powers of I in the quasistatic limit of vanishing I , in which all mechanical properties are determined by contact network geometry. The microstructure of the sheared material is characterized with a suitable parametrization of the fabric tensor and measurements of coordination numbers.
Clustering of local group distances: Publication bias or correlated measurements? II. M31 and beyond
DOE Office of Scientific and Technical Information (OSTI.GOV)
De Grijs, Richard; Bono, Giuseppe
2014-07-01
The accuracy of extragalactic distance measurements ultimately depends on robust, high-precision determinations of the distances to the galaxies in the local volume. Following our detailed study addressing possible publication bias in the published distance determinations to the Large Magellanic Cloud (LMC), here we extend our distance range of interest to include published distance moduli to M31 and M33, as well as to a number of their well-known dwarf galaxy companions. We aim at reaching consensus on the best, most homogeneous, and internally most consistent set of Local Group distance moduli to adopt for future, more general use based on themore » largest set of distance determinations to individual Local Group galaxies available to date. Based on a careful, statistically weighted combination of the main stellar population tracers (Cepheids, RR Lyrae variables, and the magnitude of the tip of the red-giant branch), we derive a recommended distance modulus to M31 of (m−M){sub 0}{sup M31}=24.46±0.10 mag—adopting as our calibration an LMC distance modulus of (m−M){sub 0}{sup LMC}=18.50 mag—and a fully internally consistent set of benchmark distances to key galaxies in the local volume, enabling us to establish a robust and unbiased, near-field extragalactic distance ladder.« less
ERIC Educational Resources Information Center
Nakahara, Tadao, Ed.; Koyama, Masataka, Ed.
The second volume of the 24th annual conference of the International Group for the Psychology of Mathematics Education contains full research report papers. Papers include: (1) "What you see is what you get: The influence of visualization on the perception of data structures" (Dan Aharoni); (2) "Exploring the transparency of graphs and graphing"…
ERIC Educational Resources Information Center
Pateman, Neil A., Ed.; Dougherty, Barbara J., Ed.; Zilliox, Joseph T., Ed.
2003-01-01
This volume of the 27th International Group for the Psychology of Mathematics Education Conference presents the following research reports: (1) Text Talk, Body Talk, Table Talk: A Design of Ratio and Proportion as Classroom Parallel Events (Dor Abrahamson); (2) Generalizing the Context and Generalising the Calculation (Janet Ainley); (3) Interview…
ERIC Educational Resources Information Center
Pateman, Neil A., Ed; Dougherty, Barbara J., Ed.; Zilliox, Joseph T., Ed.
2003-01-01
This volume of the 27th International Group for the Psychology of Mathematics Education Conference includes the following research reports: (1) The Affective Views of Primary School Children (Peter Grootenboer); (2) Theoretical Model of Analysis of Rate Problems in Algebra (Jose Guzman, Nadine Bednarz and Fernando Hitt); (3) Locating Fractions on…
ERIC Educational Resources Information Center
Pateman, Neil A., Ed; Dougherty, Barbara J., Ed.; Zilliox, Joseph T., Ed.
2003-01-01
This volume of the 27th International Group for the Psychology of Mathematics Education Conference presents papers from: plenary panels; research forums; working sessions; discussion groups; short oral communications; and poster sessions from the meeting. Plenary lectures included: (1) Studying and Capturing the Complexity of Practice: The Case of…
ERIC Educational Resources Information Center
Burns, Robin J., Ed.; Aspeslagh, Robert, Ed.
The Peace Education Commission (PEC) of the International Peace Research Association (IPRA) has been the forum for peace educators to come together, to exchange and to share ideas, materials and experiences over three decades. This book draws from key papers from different areas and times of peace education work to show the richness of ideas and…
Method and apparatus for extracting tritium and preparing radioactive waste for disposal
Heung, L.K.
1994-03-29
Apparatus is described for heating an object such as a nuclear target bundle to release and recover hydrogen and contain the disposable residue for disposal. The apparatus comprises an inverted furnace, a sleeve/crucible assembly for holding and enclosing the bundle, conveying equipment for placing the sleeve onto the crucible and loading the bundle into the sleeve/crucible, a lift for raising the enclosed bundle into the furnace, and hydrogen recovery equipment including a trap and strippers, all housed in a containment having negative internal pressure. The crucible/sleeve assembly has an internal volume that is sufficient to enclose and hold the bundle before heating; the crucible's internal volume is sufficient by itself to hold and enclose the bundle's volume after heating. The crucible can then be covered and disposed of; the sleeve, on the other hand, can be reused. 4 figures.
Potential application of machine learning in health outcomes research and some statistical cautions.
Crown, William H
2015-03-01
Traditional analytic methods are often ill-suited to the evolving world of health care big data characterized by massive volume, complexity, and velocity. In particular, methods are needed that can estimate models efficiently using very large datasets containing healthcare utilization data, clinical data, data from personal devices, and many other sources. Although very large, such datasets can also be quite sparse (e.g., device data may only be available for a small subset of individuals), which creates problems for traditional regression models. Many machine learning methods address such limitations effectively but are still subject to the usual sources of bias that commonly arise in observational studies. Researchers using machine learning methods such as lasso or ridge regression should assess these models using conventional specification tests. Copyright © 2015 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Hill, R. F.
The characterization, development, and availability of various energy sources for large scale energy production are discussed. Attention is given to government, industry, and international policies on energy resource development and implementation. Techniques for energy analysis, planning, and regulation are examined, with consideration given to conservation practices, military energy programs, and financing schemes. Efficient energy use is examined, including energy and load management, building retrofits, and cogeneration installations, as well as waste heat recovery. The state of the art of nuclear, fossil, and geothermal power extraction is investigated, with note taken of synthetic fuels, fluidized bed combustion, and pollution control in coal-powered plants. Finally, progress in renewable energy technologies, including solar heating and cooling, biomass, and large and small wind energy conversion devices is described. No individual items are abstracted in this volume
NASA Astrophysics Data System (ADS)
Savina, Irina N.; Ingavle, Ganesh C.; Cundy, Andrew B.; Mikhalovsky, Sergey V.
2016-02-01
The development of bulk, three-dimensional (3D), macroporous polymers with high permeability, large surface area and large volume is highly desirable for a range of applications in the biomedical, biotechnological and environmental areas. The experimental techniques currently used are limited to the production of small size and volume cryogel material. In this work we propose a novel, versatile, simple and reproducible method for the synthesis of large volume porous polymer hydrogels by cryogelation. By controlling the freezing process of the reagent/polymer solution, large-scale 3D macroporous gels with wide interconnected pores (up to 200 μm in diameter) and large accessible surface area have been synthesized. For the first time, macroporous gels (of up to 400 ml bulk volume) with controlled porous structure were manufactured, with potential for scale up to much larger gel dimensions. This method can be used for production of novel 3D multi-component macroporous composite materials with a uniform distribution of embedded particles. The proposed method provides better control of freezing conditions and thus overcomes existing drawbacks limiting production of large gel-based devices and matrices. The proposed method could serve as a new design concept for functional 3D macroporous gels and composites preparation for biomedical, biotechnological and environmental applications.
Labus, Jennifer S; Dinov, Ivo D; Jiang, Zhiguo; Ashe-McNalley, Cody; Zamanyan, Alen; Shi, Yonggang; Hong, Jui-Yang; Gupta, Arpana; Tillisch, Kirsten; Ebrat, Bahar; Hobel, Sam; Gutman, Boris A; Joshi, Shantanu; Thompson, Paul M; Toga, Arthur W; Mayer, Emeran A
2014-01-01
Alterations in gray matter (GM) density/volume and cortical thickness (CT) have been demonstrated in small and heterogeneous samples of subjects with differing chronic pain syndromes, including irritable bowel syndrome (IBS). Aggregating across 7 structural neuroimaging studies conducted at University of California, Los Angeles, Los Angeles, CA, USA, between August 2006 and April 2011, we examined group differences in regional GM volume in 201 predominantly premenopausal female subjects (82 IBS, mean age: 32±10 SD, 119 healthy controls [HCs], 30±10 SD). Applying graph theoretical methods and controlling for total brain volume, global and regional properties of large-scale structural brain networks were compared between the group with IBS and the HC group. Relative to HCs, the IBS group had lower volumes in the bilateral superior frontal gyrus, bilateral insula, bilateral amygdala, bilateral hippocampus, bilateral middle orbital frontal gyrus, left cingulate, left gyrus rectus, brainstem, and left putamen. Higher volume was found in the left postcentral gyrus. Group differences were no longer significant for most regions when controlling for the Early Trauma Inventory global score, with the exception of the right amygdala and the left postcentral gyrus. No group differences were found for measures of global and local network organization. Compared to HCs, in patients with IBS, the right cingulate gyrus and right thalamus were identified as being significantly more critical for information flow. Regions involved in endogenous pain modulation and central sensory amplification were identified as network hubs in IBS. Overall, evidence for central alterations in patients with IBS was found in the form of regional GM volume differences and altered global and regional properties of brain volumetric networks. Copyright © 2013 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Tecle, Amanuel Sebhatu
Hurricane is one of the most destructive and costly natural hazard to the built environment and its impact on low-rise buildings, particularity, is beyond acceptable. The major objective of this research was to perform a parametric evaluation of internal pressure (IP) for wind-resistant design of low-rise buildings and wind-driven natural ventilation applications. For this purpose, a multi-scale experimental, i.e. full-scale at Wall of Wind (WoW) and small-scale at Boundary Layer Wind Tunnel (BLWT), and a Computational Fluid Dynamics (CFD) approach was adopted. This provided new capability to assess wind pressures realistically on internal volumes ranging from small spaces formed between roof tiles and its deck to attic to room partitions. Effects of sudden breaching, existing dominant openings on building envelopes as well as compartmentalization of building interior on the IP were systematically investigated. Results of this research indicated: (i) for sudden breaching of dominant openings, the transient overshooting response was lower than the subsequent steady state peak IP and internal volume correction for low-wind-speed testing facilities was necessary. For example a building without volume correction experienced a response four times faster and exhibited 30--40% lower mean and peak IP; (ii) for existing openings, vent openings uniformly distributed along the roof alleviated, whereas one sided openings aggravated the IP; (iii) larger dominant openings exhibited a higher IP on the building envelope, and an off-center opening on the wall exhibited (30--40%) higher IP than center located openings; (iv) compartmentalization amplified the intensity of IP and; (v) significant underneath pressure was measured for field tiles, warranting its consideration during net pressure evaluations. The study aimed at wind driven natural ventilation indicated: (i) the IP due to cross ventilation was 1.5 to 2.5 times higher for Ainlet/Aoutlet>1 compared to cases where Ainlet/Aoutlet<1, this in effect reduced the mixing of air inside the building and hence the ventilation effectiveness; (ii) the presence of multi-room partitioning increased the pressure differential and consequently the air exchange rate. Overall good agreement was found between the observed large-scale, small-scale and CFD based IP responses. Comparisons with ASCE 7-10 consistently demonstrated that the code underestimated peak positive and suction IP.
NASA Astrophysics Data System (ADS)
Wang, Y.; Fu, D., Sr.
2016-12-01
The hydrological response to Land Use/Land Cover Changes (LUCC) is the most active field in the international hydrological science research, and it is also a particular concern in the process of Chinese urban construction and renewal, many studies have shown that large-scale land use change is an important factor leading to the regional climate and hydrological cycle changes. Therefore, International Geosphere-Biosphere Program (IGBP) and International Human Dimensions Programme on Global Environmental Change (IHDP), World Climate Research Program (WCRP) and International Programme of Biodiversity Science (DIVERSITAS) program take land use change as one core program. The change of regional vegetation ecosystem caused by land use change, in turn, has a very significant impact on the regional hydrological cycle. Currently the influence of hydrological processes attributed correlated with land-use type were not fully considered in urban LUCC, the hydrological effect on urban-scale LUCC has just started. Since 2015, Chinese government began to implement "Sponge City" construction, however, the sponge city construction often takes the water resources management as the target, and mainly focuses on the rational allocation of urban water resources in conjunction with ignoring the response of LUCC on the water system. The hydrological response on LUCC need to use the scenario design method to quantitatively analyze the influence degree of the hydrological change on LUCC. According to the control rate of the runoff volume and land information, the coverage rate of sponge facilities determined before planning, such as bioretention, permeable pavement and greening roof, are adjusted and then are checked on the basis of storage volume, the coverage rate of the sponge facilities that can accommodate the total runoff volume are put forward. This research addresses the hydrological response changes on the land use before and after the use of LID using the scenario design method and identifies the sponge facilities with the aid of XPDrainage software on the southern area of Fangshan National Geopark in Nanjing city, China. A technical method to evaluate the influence of land use change on hydrological process and its response during the sponge city construction process is preliminarily discussed.
NASA Astrophysics Data System (ADS)
Freymuth, Heye; Brandmeier, Melanie; Wörner, Gerhard
2015-06-01
Volcanism during the Neogene in the Central Volcanic Zone (CVZ) of the Andes produced (1) stratovolcanoes, (2) rhyodacitic to rhyolitic ignimbrites which reach volumes of generally less than 300 km3 and (3) large-volume monotonous dacitic ignimbrites of up to several thousand cubic kilometres. We present models for the origin of these magma types using O and Sr isotopes to constrain crust/mantle proportions for the large-volume ignimbrites and explore the relationship to the evolution of the Andean crust. Oxygen isotope ratios were measured on phenocrysts in order to avoid the effects of secondary alteration. Our results show a complete overlap in the Sr-O isotope compositions of lavas from stratovolcanoes and low-volume rhyolitic ignimbrites as well as older (>9 Ma) large-volume dacitic ignimbrites. This suggests that the mass balance of crustal and mantle components are largely similar. By contrast, younger (<10 Ma) large-volume dacitic ignimbrites from the southern portion of the Central Andes have distinctly more radiogenic Sr and heavier O isotopes and thus contrast with older dacitic ignimbrites in northernmost Chile and southern Peru. Results of assimilation and fractional crystallization (AFC) models show that the largest chemical changes occur in the lower crust where magmas acquire a base-level geochemical signature that is later modified by middle to upper crustal AFC. Using geospatial analysis, we estimated the volume of these ignimbrite deposits throughout the Central Andes during the Neogene and examined the spatiotemporal pattern of so-called ignimbrite flare-ups. We observe a N-S migration of maximum ages of the onset of large-volume "ignimbrite pulses" through time: Major pulses occurred at 19-24 Ma (e.g. Oxaya, Nazca Group), 13-14 Ma (e.g. Huaylillas and Altos de Pica ignimbrites) and <10 Ma (Altiplano and Puna ignimbrites). Such "flare-ups" represent magmatic production rates of 25 to >70 km3 Ma-1 km-1 (assuming plutonic/volcanic ratios of 1:5) which are additional to, but within the order of, the arc background magmatic flux. Comparing our results to average shortening rates observed in the Andes, we observe a "lag-time" with large-volume eruptions occurring after accelerated shortening. A similar delay exists between the ignimbrite pulses and the subduction of the Juan Fernandez ridge. This is consistent with the idea that large-volume ignimbrite eruptions occurred in the wake of the N-S passage of the ridge after slab steepening has allowed hot asthenospheric mantle to ascend into and cause the melting of the mantle wedge. In our model, the older large-volume dacitic ignimbrites in the northern part of the CVZ have lower (15-37 %) crustal contributions because they were produced at times when the Central Andean crust was thinner and colder, and large-scale melting in the middle crust could not be achieved. Younger ignimbrite flare-ups further south (<10 Ma, >22°S) formed with a significantly higher crustal contribution (22-68 %) because at that time the Andean crust was thicker and hotter and, therefore primed for more extensive crustal melting. The rhyolitic lower-volume ignimbrites are more equally distributed in the CVZ in time and space and are produced by mechanisms similar to those operating below large stratovolcanoes, but at times of higher melt fluxes from the mantle wedge.
Growth Chambers on the International Space Station for Large Plants
NASA Technical Reports Server (NTRS)
Massa, Gioia D.; Wheeler, Raymond M.; Morrow, Robert C.; Levine, Howard G.
2016-01-01
The International Space Station (ISS) now has platforms for conducting research on horticultural plant species under LED (Light Emitting Diodes) lighting, and those capabilities continue to expand. The Veggie vegetable production system was deployed to the ISS as an applied research platform for food production in space. Veggie is capable of growing a wide array of horticultural crops. It was designed for low power usage, low launch mass and stowage volume, and minimal crew time requirements. The Veggie flight hardware consists of a light cap containing red (630 nanometers), blue, (455 nanometers) and green (530 nanometers) LEDs. Interfacing with the light cap is an extendable bellowsbaseplate for enclosing the plant canopy. A second large plant growth chamber, the Advanced Plant Habitat (APH), is will fly to the ISS in 2017. APH will be a fully controllable environment for high-quality plant physiological research. APH will control light (quality, level, and timing), temperature, CO2, relative humidity, and irrigation, while scrubbing any cabin or plant-derived ethylene and other volatile organic compounds. Additional capabilities include sensing of leaf temperature and root zone moisture, root zone temperature, and oxygen concentration. The light cap will have red (630 nm), blue (450 nm), green (525 nm), far red (730 nm) and broad spectrum white LEDs (4100K). There will be several internal cameras (visible and IR) to monitor and record plant growth and operations. Veggie and APH are available for research proposals.
Recurrence interval analysis of trading volumes
NASA Astrophysics Data System (ADS)
Ren, Fei; Zhou, Wei-Xing
2010-06-01
We study the statistical properties of the recurrence intervals τ between successive trading volumes exceeding a certain threshold q . The recurrence interval analysis is carried out for the 20 liquid Chinese stocks covering a period from January 2000 to May 2009, and two Chinese indices from January 2003 to April 2009. Similar to the recurrence interval distribution of the price returns, the tail of the recurrence interval distribution of the trading volumes follows a power-law scaling, and the results are verified by the goodness-of-fit tests using the Kolmogorov-Smirnov (KS) statistic, the weighted KS statistic and the Cramér-von Mises criterion. The measurements of the conditional probability distribution and the detrended fluctuation function show that both short-term and long-term memory effects exist in the recurrence intervals between trading volumes. We further study the relationship between trading volumes and price returns based on the recurrence interval analysis method. It is found that large trading volumes are more likely to occur following large price returns, and the comovement between trading volumes and price returns is more pronounced for large trading volumes.
Recurrence interval analysis of trading volumes.
Ren, Fei; Zhou, Wei-Xing
2010-06-01
We study the statistical properties of the recurrence intervals τ between successive trading volumes exceeding a certain threshold q. The recurrence interval analysis is carried out for the 20 liquid Chinese stocks covering a period from January 2000 to May 2009, and two Chinese indices from January 2003 to April 2009. Similar to the recurrence interval distribution of the price returns, the tail of the recurrence interval distribution of the trading volumes follows a power-law scaling, and the results are verified by the goodness-of-fit tests using the Kolmogorov-Smirnov (KS) statistic, the weighted KS statistic and the Cramér-von Mises criterion. The measurements of the conditional probability distribution and the detrended fluctuation function show that both short-term and long-term memory effects exist in the recurrence intervals between trading volumes. We further study the relationship between trading volumes and price returns based on the recurrence interval analysis method. It is found that large trading volumes are more likely to occur following large price returns, and the comovement between trading volumes and price returns is more pronounced for large trading volumes.
Endoclips vs large or small-volume epinephrine in peptic ulcer recurrent bleeding
Ljubicic, Neven; Budimir, Ivan; Biscanin, Alen; Nikolic, Marko; Supanc, Vladimir; Hrabar, Davor; Pavic, Tajana
2012-01-01
AIM: To compare the recurrent bleeding after endoscopic injection of different epinephrine volumes with hemoclips in patients with bleeding peptic ulcer. METHODS: Between January 2005 and December 2009, 150 patients with gastric or duodenal bleeding ulcer with major stigmata of hemorrhage and nonbleeding visible vessel in an ulcer bed (Forrest IIa) were included in the study. Patients were randomized to receive a small-volume epinephrine group (15 to 25 mL injection group; Group 1, n = 50), a large-volume epinephrine group (30 to 40 mL injection group; Group 2, n = 50) and a hemoclip group (Group 3, n = 50). The rate of recurrent bleeding, as the primary outcome, was compared between the groups of patients included in the study. Secondary outcomes compared between the groups were primary hemostasis rate, permanent hemostasis, need for emergency surgery, 30 d mortality, bleeding-related deaths, length of hospital stay and transfusion requirements. RESULTS: Initial hemostasis was obtained in all patients. The rate of early recurrent bleeding was 30% (15/50) in the small-volume epinephrine group (Group 1) and 16% (8/50) in the large-volume epinephrine group (Group 2) (P = 0.09). The rate of recurrent bleeding was 4% (2/50) in the hemoclip group (Group 3); the difference was statistically significant with regard to patients treated with either small-volume or large-volume epinephrine solution (P = 0.0005 and P = 0.045, respectively). Duration of hospital stay was significantly shorter among patients treated with hemoclips than among patients treated with epinephrine whereas there were no differences in transfusion requirement or even 30 d mortality between the groups. CONCLUSION: Endoclip is superior to both small and large volume injection of epinephrine in the prevention of recurrent bleeding in patients with peptic ulcer. PMID:22611315
Geavlete, Bogdan; Stanescu, Florin; Iacoboaie, Catalin; Geavlete, Petrisor
2013-05-01
WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: According to the EAU Guidelines 2012, large size benign prostatic hyperplasia (BPH) cases (>80 mL) continue to have open prostatectomy as the first line treatment alternative, despite the substantial peri-operative morbidity and extended catheterization and convalescence periods related to this undoubtedly invasive approach. During the past two decades, holmium laser enucleation of the prostate was constantly described as a successful choice for this category of patients. According to rather numerous studies, the technique displayed superior results in terms of surgical safety and postoperative recovery compared with the open procedure. On the other hand, the concept of electrosurgical enucleation of the prostate, using either a monopolar or bipolar cutting current, materialized into several technical applications that eventually failed to gain general acknowledgement as reliable alternatives to the BPH transurethral approach. While keeping in mind the already proved advantage of enucleating substantial quantities of BPH tissue, bipolar plasma enucleation of the prostate was introduced as a novel endoscopic approach in cases of large prostates. The present trial represents the first prospective, medium-term, randomized comparison to be published of this innovative technique with standard open prostatectomy. Basically, the premises for a viable alternative relied on the practical advantages provided by the 'button' electrode, mainly the large surface creating the conditions for a fast enucleation process, continuous vaporization and concomitant haemostasis. Eventually, it was concluded that the plasma enucleation procedure distinguished itself as a successful treatment option in large BPH patients, characterized by good surgical efficiency, significantly reduced complications, faster postoperative recovery, similar prostatic tissue ablation capabilities and satisfactory follow-up results compared with the open technique. Most importantly, plasma-button enucleation patients benefited from a similar 12 months' outcome from the perspectives of symptom scores and voiding parameters when drawing a parallel with open surgery results, thus underlining the reliable viability of this type of endoscopic approach. To evaluate the viability of bipolar plasma enucleation of the prostate (BPEP) by comparison with open transvesical prostatectomy (OP) in cases of large prostates with regard to surgical efficacy and peri-operative morbidity. To compare the medium-term follow-up parameters specific for the two methods. A total of 140 benign prostatic hyperplasia (BPH) patients with prostate volume >80 mL, maximum flow rate (Qmax ) <10 mL/s and International Prostate Symptom Score (IPSS) >19 were randomized in the two study arms. All cases were assessed preoperatively and at 1, 3, 6 and 12 months after surgery by IPSS, Qmax , quality of life score (QoL) and post-voiding residual urinary volume (PVR). The prostate volume and prostate specific antigen (PSA) level were measured at 6 and 12 months. The BPEP and OP techniques emphasized similar mean operating durations (91.4 vs 87.5 min) and resected tissue weights (108.3 vs 115.4 g). The postoperative haematuria rate (2.9% vs 12.9%) as well as the mean haemoglobin drop (1.7 vs 3.1 g/dL), catheterization period (1.5 vs 5.8 days) and hospital stay (2.1 vs 6.9 days) were significantly improved for BPEP. Recatheterization for acute urinary retention was more frequent in the OP group (8.6% vs 1.4%), while the rates of early irritative symptoms were similar for BPEP and OP (11.4% vs 7.1%). During the follow-up period, no statistically significant difference was determined in terms of IPSS, Qmax , QoL, PVR, PSA level and postoperative prostate volume between the two series. BPEP represents a promising endoscopic approach in large BPH cases, characterized by good surgical efficiency and similar BPH tissue removal capabilities compared with standard transvesical prostatectomy. BPEP patients benefited from significantly reduced complications, shorter convalescence and satisfactory follow-up symptom scores and voiding parameters. © 2013 BJU International.
Commercialization of a novel fermentation concept.
Mazumdar-Shaw, Kiran; Suryanarayan, Shrikumar
2003-01-01
Fermentation is the core of biotechnology where current methodologies span across technologies based on the use of either solid or liquid substrates. Traditionally, solid substrate fermentation technologies have been the widely practiced in the Far East to manufacture fermented foods such as soya sauce, sake etc. The Western World briefly used solid substrate fermentation for the manufacture of antibiotics and enzymes but rapidly replaced this technology with submerged fermentation which proved to be a superior technology in terms of automation, containment and large volume fermentation. Biocon India developed its enzyme technology based on solid substrate fermentation as a low-cost, low-energy option for the production of specialty enzymes. However, the limitations of applying solid substrate fermentation to more sophisticated biotechnology products as well as large volume fermentations were recognized by Biocon India as early as 1990 and the company embarked on a 8 year research and development program to develop a novel bioreactor capable of conducting solid substrate fermentation with comparable levels of automation and containment as those practiced by submerged fermentation. In addition, the novel technology enabled fed-batch fermentation, in situ extraction and other enabling features that will be discussed in this article. The novel bioreactor was christened the "PlaFractor" (pronounced play-fractor). The next level of research on this novel technology is now focused on addressing large volume fermentation. This article traces the evolution of Biocon India's original solid substrate fermentation to the PlaFractor technology and provides details of the scale-up and commercialization processes that were involved therein. What is also apparent in the article is Biocon India's commercially focused research programs and the perceived need to be globally competitive through low costs of innovation that address, at all times, processes and technologies that exhibit high degrees of conformance to the international standards of regulatory and good manufacturing practice.
Aquablation Procedural Outcomes for BPH in Large Prostates (80-150cc): Initial Experience.
Desai, Mihir; Bidair, Mo; Bhojani, Naeem; Trainer, Andrew; Arther, Andrew; Kramolowsky, Eugene; Doumanian, Leo; Elterman, Dean; Kaufman, Ronald P; Lingeman, James; Krambeck, Amy; Eure, Gregg; Badlani, Gopal; Plante, Mark; Uchio, Edward; Gin, Greg; Goldenberg, Larry; Paterson, Ryan; So, Alan; Humphreys, Mitch; Roehrborn, Claus; Kaplan, Steven; Motola, Jay; Zorn, Kevin C
2018-04-25
To present early safety and feasibility data from a multicenter prospective study of Aquablation in treatment of symptomatic men with large volume BPH. Between September and December 2017, 101 men with moderate-to-severe BPH symptoms and prostate volume of 80-150cc underwent Aquablation in a prospective multicenter international clinical trial. Baseline demographics and standardized postoperative management parameters were carefully recorded in a central independently monitored database. Surgeons answered analog scale questionnaires on intraoperative technical factors and postoperative management. Adverse events through 1 month were adjudicated by an independent clinical events committee. Mean prostate volume was 107cc (range 80 to 150). Mean operative time was 37 minutes (range 15-97) and mean Aquablation resection time was 8 minutes (range 3-15). Adequate adenoma resection was achieved with a single pass in 34 patients and additional passes in 67 patients (mean 1.8 treatment passes), all in a single operative session. Hemostasis was achieved using either a Foley balloon catheter placed in the bladder under traction (N=98, mean duration 18 hours) or direct tamponade using a balloon inflated in the prostate fossa (N=3, mean duration 15 hours). No subject required electrocautery for hemostasis at the time of primary procedure. The average length of stay following the procedure was 1.6 days (range same day-6 days). The observed Clavien-Dindo (CD) grade 2 or higher event rate at 1 month was 29.7%. Bleeding complications were recorded in 10 (9.9%) patients during the index procedure hospitalization prior to discharge and included six (5.9%) peri-operative transfusions. Aquablation is feasible and safe in treating men with men with large prostates (80-150cc). The six month efficacy data are being accrued and will be presented in future publications (number, NCT03123250). This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Robot-assisted simple prostatectomy: multi-institutional outcomes for glands larger than 100 grams.
Vora, Anup; Mittal, Sameer; Hwang, Jonathan; Bandi, Gaurav
2012-05-01
To present our experience with robot-assisted simple prostatectomy in patients with large gland adenoma (>100 g) that would not be amenable to transurethral treatments. From August 2009 to May 2011, 13 robot-assisted simple suprapubic prostatectomies were performed in patients with symptomatic large gland (>100 g) prostatomegaly on transrectal ultrasonography (mean 163 cc). Essential aspects of our technique include a transverse cystotomy just proximal to the prostatovesical junction and use of a robotic tenotomy grasper to aid in adenoma dissection. Mean operative time was 179 minutes (range 90-270 min), and mean estimated blood loss was 219 mL (range 50-500 mL). Mean hospital stay was 2.7 days (range 1-8 d), and the mean urethral catheterization time was 8.8 days (range 5-14 d). None of the patients needed blood transfusion. One patient had an intraoperative urinary leak after bladder closure that was managed with prolonged urethral catheterization (14 d). Histopathologic analysis confirmed benign prostatic hyperplasia (BPH) in all patients, and mean specimen weight on pathologic examination was 127 g (range 100-165 g). Mean follow-up duration was 7.2 months with all patients having a minimum of a 4-month follow-up. Significant improvements were noted in the International Prostate Symptom Score (preoperative vs postoperative 18.1 vs 5.3, p<0.001) and the maximum urine flow rate (preoperative vs postoperative 4.3 vs 19.1 mL/min, P<0.001). Minimally invasive robot-assisted simple prostatectomy is technically feasible in patients with large volume (>100 g) BPH and is associated with significant improvements in obstructive urinary symptoms. Surgeons with robotic expertise may consider using this approach for treatment of their patients with large volume BPH.
Marketing ITS infrastructure in the public interest
DOT National Transportation Integrated Search
2000-10-01
This guide, Volume 4 - Bibliographic and Non-bibliographic databases, is part of the International Guide to Highway Transportation Information - a multi-volume set of guides that provides highway transportation information resources for domestic and ...
Ninteenth International Cosmic Ray Conference. OG Sessions, Volume 1
NASA Technical Reports Server (NTRS)
Jones, F. C. (Compiler)
1985-01-01
Contributed papers addressing cosmic ray origin and galactic phenomena are compiled. The topic areas covered in this volume include gamma ray bursts, gamma rays from point sources, and diffuse gamma ray emission.
Code of Federal Regulations, 2010 CFR
2010-10-01
... International Labor Office and described in “Medical Radiography and Photography,” volume 48, No. 3, December... Radiography and Photography” volume 57, No. 1, 1981, and in ILO publication 22 (revised 1980) from the ILO...
Pragmatics & Language Learning. Volume 14
ERIC Educational Resources Information Center
Bardovi-Harlig, Kathleen, Ed.; Félix-Brasdefer, J. César, Ed.
2016-01-01
This volume contains a selection of papers presented at the 2014 International Conference of Pragmatics and Language Learning at Indiana University. It includes fourteen papers on a variety of topics, with a diversity of first and second languages, and a wide range of methods used to collect pragmatic data in L2 and FL settings. This volume is…
Negating Tissue Contracture Improves Volume Maintenance and Longevity of In Vivo Engineered Tissues.
Lytle, Ian F; Kozlow, Jeffrey H; Zhang, Wen X; Buffington, Deborah A; Humes, H David; Brown, David L
2015-10-01
Engineering large, complex tissues in vivo requires robust vascularization to optimize survival, growth, and function. Previously, the authors used a "chamber" model that promotes intense angiogenesis in vivo as a platform for functional three-dimensional muscle and renal engineering. A silicone membrane used to define the structure and to contain the constructs is successful in the short term. However, over time, generated tissues contract and decrease in size in a manner similar to capsular contracture seen around many commonly used surgical implants. The authors hypothesized that modification of the chamber structure or internal surface would promote tissue adherence and maintain construct volume. Three chamber configurations were tested against volume maintenance. Previously studied, smooth silicone surfaces were compared to chambers modified for improved tissue adherence, with multiple transmembrane perforations or lined with a commercially available textured surface. Tissues were allowed to mature long term in a rat model, before analysis. On explantation, average tissue masses were 49, 102, and 122 mg; average volumes were 74, 158 and 176 μl; and average cross-sectional areas were 1.6, 6.7, and 8.7 mm for the smooth, perforated, and textured groups, respectively. Both perforated and textured designs demonstrated significantly greater measures than the smooth-surfaced constructs in all respects. By modifying the design of chambers supporting vascularized, three-dimensional, in vivo tissue engineering constructs, generated tissue mass, volume, and area can be maintained over a long time course. Successful progress in the scale-up of construct size should follow, leading to improved potential for development of increasingly complex engineered tissues.
Evaluating the feasibility of the KDIGO CKD referral recommendations.
Singh, Karandeep; Waikar, Sushrut S; Samal, Lipika
2017-07-07
In 2012, the international nephrology organization Kidney Disease Improving Global Outcomes (KDIGO) released recommendations for nephrology referral for chronic kidney disease (CKD) patients. The feasibility of adhering to these recommendations is unknown. We conducted a retrospective analysis of the primary care population at Brigham and Women's Hospital (BWH). We translated referral recommendations based upon serum creatinine, estimated glomerular filtration rate (eGFR), and albuminuria into a set of computable criteria in order to project referral volume if the KDIGO referral recommendations were to be implemented. Using electronic health record data, we evaluated each patient using the computable criteria at the times that the patient made clinic visits in 2013. We then compared the projected referral volume with baseline nephrology clinic volume. Out of 56,461 primary care patients at BWH, we identified 5593 (9.9%) who had CKD based on albuminuria or estimated GFR. Referring patients identified by the computable criteria would have resulted in 2240 additional referrals to nephrology. In 2013, this would represent a 38.0% (2240/5892) increase in total nephrology patient volume and 67.3% (2240/3326) increase in new referral volume. This is the first study to examine the projected impact of implementing the 2012 KDIGO referral recommendations. Given the large increase in the number of referrals, this study is suggestive that implementing the KDIGO referral guidelines may not be feasible under current practice models due to a supply-demand mismatch. We need to consider new strategies on how to deliver optimal care to CKD patients using the available workforce in the U.S. health care system.
Fungi and wind strongly influence the temporal availability of logs in an old-growth spruce forest.
Edman, Mattias; Jönsson, Mari; Jonsson, Bengt Gunnar
2007-03-01
Coarse woody debris (CWD) is a key habitat for many species in forest ecosystems. To ensure the long-term survival of such species, forest management regimes must include measures that promote dead wood dynamics similar to those of natural forests. Thus, information on CWD dynamics under natural conditions is required, including data pertaining to the underlying agents of disturbance. This study examines modes of mortality, decay rates, and temporal patterns in the availability of Picea abies logs in a Swedish old-growth forest affected by internal, small-scale disturbance. All 684 logs in a 6.6-ha plot were mapped and classified into one of six decay classes. Logs in the early stages of decay were examined for the presence of heart-rot fungi. Six years later all logs were re-inventoried, including newly formed logs. Matrix models based on the transition rates between decay classes showed that it took about 60 years for 90% of the logs to decay beyond class 6 (a deformed trunk with soft wood). Large logs (> 26 cm) decayed 40% more slowly than small logs (< 25 cm). The initial volume of logs was 37.6 m3/ha but increased to 44.8 m3/ha after six years. In addition, there was a large shift in the decay-class distribution. The volume of logs in early and late decay classes increased by 71% and 45%, respectively, while the volume of logs in the intermediate decay classes decreased by 32%. The fluctuations appear to result from pulses in mortality, driven by a combination of strong winds and the heart-rot fungus, Phellinus chrysoloma, which was present in more than 30% of all logs at an early stage of decay. These results show that large temporal fluctuations in dead wood also occur in the absence of large-scale disturbance, and that heart-rot fungi are important factors driving the overall dynamics of dead wood. Since many wood-inhabiting species are naturally rare and have very specific substrate demands, such temporal variability in dead wood availability may have effects on biodiversity and should be taken into account when designing small, protected forest areas.
Lin, Yen-Ting; Amouyal, Grégory; Correas, Jean-Michel; Pereira, Héléna; Pellerin, Olivier; Del Giudice, Costantino; Déan, Carole; Thiounn, Nicolas; Sapoval, Marc
2016-10-01
To assess the impact of prostatic arterial embolisation (PAE) on various prostate gland anatomical zones. We retrospectively reviewed paired MRI scans obtained before and after PAE for 25 patients and evaluated changes in volumes of the median lobe (ML), central gland (CG), peripheral zone (PZ) and whole prostate gland (WPV) following PAE. We used manual segmentation to calculate volume on axial view T2-weighted images for ML, CG and WPV. We calculated PZ volume by subtracting CG volume from WPV. Enhanced phase on dynamic contrasted-enhanced MRI was used to evaluate the infarction areas after PAE. Clinical results of International Prostate Symptom Score and International Index of Erectile Function questionnaires and the urodynamic study were evaluated before and after PAE. Significant reductions in volume were observed after PAE for ML (26.2 % decrease), CG (18.8 %), PZ (16.4 %) and WPV (19.1 %; p < 0.001 for all these volumes). Patients with clinical failure had smaller volume reductions for WPV, ML and CG (all p < 0.05). Patients with significant CG infarction after PAE displayed larger WPV, ML and CG volume reductions (all p < 0.01). PAE can significantly decrease WPV, ML, CG and PZ volumes, and poor clinical outcomes are associated with smaller volume reductions. • The MRI segmentation method provides detailed comparisons of prostate volume change. • Prostatic arterial embolisation (PAE) decreased central gland and peripheral zone volumes. • Prostates with infarction after PAE showed larger decreases in volume. • A larger decrease in prostate volume is associated with clinical success.
An Empirical Study on the Determinants of International Student Mobility: A Global Perspective
ERIC Educational Resources Information Center
Wei, Hao
2013-01-01
This paper, based on the data of 48 countries and regions from 1999 to 2008, studies the economic and educational determinants of how countries of different types attract international students. The study finds that: the volume of merchandise trade between countries facilitates international student mobility across borders; international students…
The role of Thailand in the international trade in CITES-listed live reptiles and amphibians.
Nijman, Vincent; Shepherd, Chris R
2011-03-25
International wildlife trade is one of the leading threats to biodiversity conservation. The Convention on International Trade in Endangered Species of Wild Fauna and Flora (CITES) is the most important initiative to monitor and regulate the international trade of wildlife but its credibility is dependent on the quality of the trade data. We report on the performance of CITES reporting by focussing on the commercial trade in non-native reptiles and amphibians into Thailand as to illustrate trends, species composition and numbers of wild-caught vs. captive-bred specimens. Based on data in the WCMC-CITES trade database, we establish that a total of 75,594 individuals of 169 species of reptiles and amphibians (including 27 globally threatened species) were imported into Thailand in 1990-2007. The majority of individuals (59,895, 79%) were listed as captive-bred and a smaller number (15,699, 21%) as wild-caught. In the 1990s small numbers of individuals of a few species were imported into Thailand, but in 2003 both volumes and species diversity increased rapidly. The proportion of captive-bred animals differed greatly between years (from 0 to >80%). Wild-caught individuals were mainly sourced from African countries, and captive-bred individuals from Asian countries (including from non-CITES Parties). There were significant discrepancies between exports and imports. Thailand reports the import of >10,000 individuals (51 species) originating from Kazakhstan, but Kazakhstan reports no exports of these species. Similar discrepancies, involving smaller numbers (>100 individuals of 9 species), can be seen in the import of reptiles into Thailand via Macao. While there has been an increase in imports of amphibian and reptiles into Thailand, erratic patterns in proportions of captive-bred specimens and volumes suggests either capricious markets or errors in reporting. Large discrepancies with respect to origin point to misreporting or possible violations of the rules and intentions of CITES.
The Role of Thailand in the International Trade in CITES-Listed Live Reptiles and Amphibians
Nijman, Vincent; Shepherd, Chris R.
2011-01-01
Background International wildlife trade is one of the leading threats to biodiversity conservation. The Convention on International Trade in Endangered Species of Wild Fauna and Flora (CITES) is the most important initiative to monitor and regulate the international trade of wildlife but its credibility is dependent on the quality of the trade data. We report on the performance of CITES reporting by focussing on the commercial trade in non-native reptiles and amphibians into Thailand as to illustrate trends, species composition and numbers of wild-caught vs. captive-bred specimens. Methodology/Principal Findings Based on data in the WCMC-CITES trade database, we establish that a total of 75,594 individuals of 169 species of reptiles and amphibians (including 27 globally threatened species) were imported into Thailand in 1990–2007. The majority of individuals (59,895, 79%) were listed as captive-bred and a smaller number (15,699, 21%) as wild-caught. In the 1990s small numbers of individuals of a few species were imported into Thailand, but in 2003 both volumes and species diversity increased rapidly. The proportion of captive-bred animals differed greatly between years (from 0 to >80%). Wild-caught individuals were mainly sourced from African countries, and captive-bred individuals from Asian countries (including from non-CITES Parties). There were significant discrepancies between exports and imports. Thailand reports the import of >10,000 individuals (51 species) originating from Kazakhstan, but Kazakhstan reports no exports of these species. Similar discrepancies, involving smaller numbers (>100 individuals of 9 species), can be seen in the import of reptiles into Thailand via Macao. Conclusion/Significance While there has been an increase in imports of amphibian and reptiles into Thailand, erratic patterns in proportions of captive-bred specimens and volumes suggests either capricious markets or errors in reporting. Large discrepancies with respect to origin point to misreporting or possible violations of the rules and intentions of CITES. PMID:21464976
ERIC Educational Resources Information Center
Concheiro, A. Alonso, Ed.; And Others
The following papers in English from this international conference may be of particular interest to those in the field of education. T. Nakahara, A. Tsukamota, and M. Matsumoto describe a computer-aided design technique for an economical urban cable television system. W. D. Wasson and R. K. Chitkara outline a recognition scheme based on analysis…
ERIC Educational Resources Information Center
Protheroe, Mervyn, Ed.
2012-01-01
The 10 articles in this 7th volume comprise the refereed proceedings of the 2011 ATLAANZ (Association of Tertiary Learning Advisors Aotearoa/New Zealand) conference. In Chapter 1, Cath Fraser and Pam Simpson ("Offshore-onshore: How international students' expectations of the New Zealand academic environment compare to their lived…
Sewage sludge pasteurization by gamma radiation: Financial viability case studies
NASA Astrophysics Data System (ADS)
Swinwood, Jean F.; Kotler, Jiri
This paper examines the financial viability of sewage sludge pasteurization by gamma radiation, by examining the following three North American scenarios: 1) Small volume sewage treatment plant experiencing high sludge disposal costs. 2) Large volume sewage treatment plant experiencing low sludge disposal costs. 3) Large volume sewage treatment plant experiencing high sludge disposal costs.
Amore, Valentina; Hernández, Malva I.M.; Carrascal, Luis M.
2017-01-01
The insect exoskeleton is a multifunctional coat with a continuum of mechanical and structural properties constituting the barrier between electromagnetic waves and the internal body parts. This paper examines the ability of beetle exoskeleton to regulate internal body temperature considering its thermal permeability or isolation to simulated solar irradiance and infrared radiation. Seven Neotropical species of dung beetles (Coleoptera, Scarabaeinae) differing in colour, surface sculptures, size, sexual dimorphism, period of activity, guild category and altitudinal distribution were studied. Specimens were repeatedly subjected to heating trials under simulated solar irradiance and infrared radiation using a halogen neodymium bulb light with a balanced daylight spectrum and a ceramic infrared heat emitter. The volume of exoskeleton and its weight per volume unit were significantly more important for the heating rate at the beginning of the heating process than for the asymptotic maximum temperature reached at the end of the trials: larger beetles with relatively thicker exoskeletons heated more slowly. The source of radiation greatly influences the asymptotic temperature reached, but has a negligible effect in determining the rate of heat gain by beetles: they reached higher temperatures under artificial sunlight than under infrared radiation. Interspecific differences were negligible in the heating rate but had a large magnitude effect on the asymptotic temperature, only detectable under simulated sun irradiance. The fact that sun irradiance is differentially absorbed dorsally and transformed into heat among species opens the possibility that differences in dorsal exoskeleton would facilitate the heat gain under restrictive environmental temperatures below the preferred ones. The findings provided by this study support the important role played by the exoskeleton in the heating process of beetles, a cuticle able to act passively in the thermal control of body temperature without implying energetic costs and metabolic changes. PMID:28533987
Amore, Valentina; Hernández, Malva I M; Carrascal, Luis M; Lobo, Jorge M
2017-01-01
The insect exoskeleton is a multifunctional coat with a continuum of mechanical and structural properties constituting the barrier between electromagnetic waves and the internal body parts. This paper examines the ability of beetle exoskeleton to regulate internal body temperature considering its thermal permeability or isolation to simulated solar irradiance and infrared radiation. Seven Neotropical species of dung beetles (Coleoptera, Scarabaeinae) differing in colour, surface sculptures, size, sexual dimorphism, period of activity, guild category and altitudinal distribution were studied. Specimens were repeatedly subjected to heating trials under simulated solar irradiance and infrared radiation using a halogen neodymium bulb light with a balanced daylight spectrum and a ceramic infrared heat emitter. The volume of exoskeleton and its weight per volume unit were significantly more important for the heating rate at the beginning of the heating process than for the asymptotic maximum temperature reached at the end of the trials: larger beetles with relatively thicker exoskeletons heated more slowly. The source of radiation greatly influences the asymptotic temperature reached, but has a negligible effect in determining the rate of heat gain by beetles: they reached higher temperatures under artificial sunlight than under infrared radiation. Interspecific differences were negligible in the heating rate but had a large magnitude effect on the asymptotic temperature, only detectable under simulated sun irradiance. The fact that sun irradiance is differentially absorbed dorsally and transformed into heat among species opens the possibility that differences in dorsal exoskeleton would facilitate the heat gain under restrictive environmental temperatures below the preferred ones. The findings provided by this study support the important role played by the exoskeleton in the heating process of beetles, a cuticle able to act passively in the thermal control of body temperature without implying energetic costs and metabolic changes.
Recombinant production and solution structure of lipid transfer protein from lentil Lens culinaris
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gizatullina, Albina K.; Moscow Institute of Physics and Technology; Finkina, Ekaterina I.
2013-10-04
Highlights: •Lipid transfer protein from lentil seeds (Lc-LTP2) was overexpressed in E. coli. •Antimicrobial activity and spatial structure of the recombinant Lc-LTP2 were examined. •Internal tunnel-like lipid-binding cavity occupies ∼7% of the total Lc-LTP2 volume. •Binding of DMPG lipid induces moderate rearrangements in the Lc-LTP2 structure. •Lc-LTP2/DMPG complex has limited lifetime and dissociates within tens of hours. -- Abstract: Lipid transfer protein, designated as Lc-LTP2, was isolated from seeds of the lentil Lens culinaris. The protein has molecular mass 9282.7 Da, consists of 93 amino acid residues including 8 cysteines forming 4 disulfide bonds. Lc-LTP2 and its stable isotope labeledmore » analogues were overexpressed in Escherichia coli and purified. Antimicrobial activity of the recombinant protein was examined, and its spatial structure was studied by NMR spectroscopy. The polypeptide chain of Lc-LTP2 forms four α-helices (Cys4-Leu18, Pro26-Ala37, Thr42-Ala56, Thr64-Lys73) and a long C-terminal tail without regular secondary structure. Side chains of the hydrophobic residues form a relatively large internal tunnel-like lipid-binding cavity (van der Waals volume comes up to ∼600 Å{sup 3}). The side-chains of Arg45, Pro79, and Tyr80 are located near an assumed mouth of the cavity. Titration with dimyristoyl phosphatidylglycerol (DMPG) revealed formation of the Lc-LTP2/lipid non-covalent complex accompanied by rearrangements in the protein spatial structure and expansion of the internal cavity. The resultant Lc-LTP2/DMPG complex demonstrates limited lifetime and dissociates within tens of hours.« less
Qureshi, Waqas T.; Leigh, J. Adam; Swett, Katrina; Ajay, Dharod; Allison, Matthew A.; Cai, Jianwen; Gonzalez, Franklyn; Hurwitz, Barry E.; Shah, Sanjiv J.; Desai, Ankit A.; Spevack, Daniel M.; Rodriguez, Carlos J.
2015-01-01
Background Reference limits for echocardiographic quantification of cardiac chambers in Hispanics are not well studied. Methods and Results We examined the reference values of left atrium (LA) and ventricle (LV) structure in a large ethnically diverse Hispanic cohort. Two-dimensional transthoracic echocardiography was performed in 1,818 participants of the Echocardiographic Study of Latinos (ECHO-SOL). Individuals with body mass index ≥30kg/m2, hypertension, diabetes mellitus, coronary artery disease and atrial fibrillation were excluded leaving 525 participants defined as healthy reference-cohort. We estimated 95th weighted percentiles of LV end systolic volume, LV end diastolic volume, relative wall and septal thickness, LV mass and left atrial volume. We then used upper reference limits of the 2005 and 2015 American Society of Echocardiography (ASE) and 95th percentile of reference cohort to classify the Hispanic Community Health Study/Study of Latinos (HCHS/SOL) target population into abnormal and normal. Reference limits were also calculated for each of 6 Hispanic origins. Using ASE 2015 defined reference values we categorized 7%, 21%, 57% and 17% of males and 18%, 29%, 60% and 26% of females as having abnormal LV mass index, relative, septal and posterior wall thickness, respectively. Conversely, 10%, and 11% of males and 4% and 2% of females were classified as having abnormal end-diastolic volume and internal diameter by ASE 2015 cut-offs, respectively. Similar differences were found when we used 2005 ASE cut offs. Several differences were noted in distribution of cardiac structure and volumes among various Hispanic/Latino origins. Cubans had highest values of echocardiographic measures and Central Americans had the lowest. Conclusions This is the first large study that provides normal reference values for cardiac structure. It further demonstrates that a considerable segment of Hispanic/Latinos residing in US may be classified as having abnormal measures of cardiac chambers when 2015 and 2005 ASE reference cut-offs are used. PMID:26712159
Effect of cold drawing ratio on γ′ precipitation in Inconel X-750
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ha, Jeong Won; Research and Development Center, KOS Limited, Yangsan 626-230; Seong, Baek Seok
2014-10-15
Inconel X-750 is a Ni-based precipitation-hardened superalloy having large tensile and fracture strengths. In the study, X-750 wires were cold drawn to different extents. Small angle neutron scattering was employed to quantitatively measure the size and volume fraction of the γ′ phase as a function of the cold drawing ratio (DR) and aging temperature. The presence and size of γ′ precipitates were confirmed by transmission electron microscopy. The drawing ratio had an important effect on the volume fraction of the γ′ precipitates. However, the size of the precipitates was independent on the drawing ratio. The specimen with the minimum drawingmore » ratio (DR0) produced the largest volume fraction of γ′ as compared with large drawing ratio (DR) specimens such as DR17 and DR42. The small volume fraction of the γ′ phase for a sizeable drawing ratio was associated with the large amount of nucleation sites for secondary carbides, M{sub 23}C{sub 6}, and the fast diffusion path, i.e., dislocation, needed to form M{sub 23}C{sub 6}. A Cr depletion zone around the secondary carbides raised the solubility of γ′. Therefore, the significant drawing ratio contributing to the large volume fraction of the secondary carbides decreased the volume fraction of the γ′ precipitates in Inconel X-750. - Highlights: • The volume fraction of secondary carbides increased with the drawing ratio. • The volume fraction of γ′ decreased as the drawing ratio increased. • The drawing ratio affected the γ′ volume fraction with no variation of the γ' size. • The volume fraction of γ′ was affected by the secondary carbide volume fraction.« less
Tuerk, Carola; Zhang, Haobo; Sachdev, Perminder; Lord, Stephen R; Brodaty, Henry; Wen, Wei; Delbaere, Kim
2016-01-01
Concern about falling is common in older people. Various related psychological constructs as well as poor balance and slow gait have been associated with decreased gray matter (GM) volume in old age. The current study investigates the association between concern about falling and voxel-wise GM volumes. A total of 281 community-dwelling older people aged 70-90 years underwent structural magnetic resonance imaging. Concern about falling was assessed using Falls Efficacy Scale-International (FES-I). For each participant, voxel-wise GM volumes were generated with voxel-based morphometry and regressed on raw FES-I scores (p < .05 family-wise error corrected on cluster level). FES-I scores were negatively correlated with total brain volume (r = -.212; p ≤ .001), GM volume (r = -.210; p ≤ .001), and white matter volume (r = -.155; p ≤ .001). Voxel-based morphometry analysis revealed significant negative associations between FES-I and GM volumes of (i) left cerebellum and bilateral inferior occipital gyrus (voxels-in-cluster = 2,981; p < .001) and (ii) bilateral superior frontal gyrus and left supplementary motor area (voxels-in-cluster = 1,900; p = .004). Additional adjustment for vision and physical fall risk did not alter these associations. After adjustment for anxiety, only left cerebellum and bilateral inferior occipital gyrus remained negatively associated with FES-I scores (voxels-in-cluster = 2,426; p < .001). Adjustment for neuroticism removed all associations between FES-I and GM volumes. Our study findings show that concern about falling is negatively associated with brain volumes in areas important for emotional control and for motor control, executive functions and visual processing in a large sample of older men and women. Regression analyses suggest that these relationships were primarily accounted for by psychological factors (generalized anxiety and neuroticism) and not by physical fall risk or vision. © The Author 2015. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Chen, Chong; Copley, Jonathan T; Linse, Katrin; Rogers, Alex D; Sigwart, Julia D
2015-01-01
The 'scaly-foot gastropod' (Chrysomallon squamiferum Chen et al., 2015) from deep-sea hydrothermal vent ecosystems of the Indian Ocean is an active mobile gastropod occurring in locally high densities, and it is distinctive for the dermal scales covering the exterior surface of its foot. These iron-sulfide coated sclerites, and its nutritional dependence on endosymbiotic bacteria, are both noted as adaptations to the extreme environment in the flow of hydrogen sulfide. We present evidence for other adaptations of the 'scaly-foot gastropod' to life in an extreme environment, investigated through dissection and 3D tomographic reconstruction of the internal anatomy. Our anatomical investigations of juvenile and adult specimens reveal a large unganglionated nervous system, a simple and reduced digestive system, and that the animal is a simultaneous hermaphrodite. We show that Chrysomallon squamiferum relies on endosymbiotic bacteria throughout post-larval life. Of particular interest is the circulatory system: Chrysomallon has a very large ctenidium supported by extensive blood sinuses filled with haemocoel. The ctenidium provides oxygen for the host but the circulatory system is enlarged beyond the scope of other similar vent gastropods. At the posterior of the ctenidium is a remarkably large and well-developed heart. Based on the volume of the auricle and ventricle, the heart complex represents approximately 4 % of the body volume. This proportionally giant heart primarily sucks blood through the ctenidium and supplies the highly vascularised oesophageal gland. Thus we infer the elaborate cardiovascular system most likely evolved to oxygenate the endosymbionts in an oxygen poor environment and/or to supply hydrogen sulfide to the endosymbionts. This study exemplifies how understanding the autecology of an organism can be enhanced by detailed investigation of internal anatomy. This gastropod is a large and active species that is abundant in its hydrothermal vent field ecosystem. Yet all of its remarkable features-protective dermal sclerites, circulatory system, high fecundity-can be viewed as adaptations beneficial to its endosymbiont microbes. We interpret these results to show that, as a result of specialisation to resolve energetic needs in an extreme chemosynthetic environment, this dramatic dragon-like species has become a carrying vessel for its bacteria.
Roumeliotis, M; Long, K; Phan, T; Graham, D; Quirk, S
2018-06-05
The aim of this study was to understand the international standard practice for radiation therapy treatment techniques and clinical priorities for institutions including the internal mammary lymph nodes (IMLNs) in the target volume for patients with synchronous bilateral breast cancer. An international survey was developed to include questions that would provide awareness of favored treatment techniques, treatment planning and delivery resource requirements, and the clinical priorities that may lead to the utilization of preferred treatment techniques. Of the 135 respondents, 82 indicated that IMLNs are regularly included in the target volume for radiation therapy (IMLN-inclusion) when the patient is otherwise generally indicated for regional nodal irradiation. Of the 82 respondents that regularly include IMLNs, five were removed as those respondents do not treat this population synchronously. Of the 77 respondents, institutional standard of care varied significantly, though VMAT (34%) and combined static photon and electron fields (21%) were the most commonly utilized techniques. Respondents did preferentially select target volume coverage (70%) as the most important clinical priority, followed by normal tissue sparing (25%). The results of the survey indicate that the IMLN-inclusion for radiation therapy has not yet been comprehensively adopted. As well, no consensus on best practice for radiation therapy treatment techniques has been reached.
The Current State of Data Transmission Channels from Pushchino to Moscow and Perspectives
NASA Astrophysics Data System (ADS)
Dumsky, D. V.; Isaev, E. A.; Samodurov, V. A.; Shatskaya, M. V.
Since the work of a unique space radio telescope in the international VLBI project "Radioastron" extended to 2017 the transmission and storage of large volumes of scientific and telemetry data obtained during the experiments is still remains actual. This project is carried out by the Astro Space Center of Lebedev Physical Institute in Moscow, Russia. It requires us to maintain in operating state the high-speed link to merge into a single LAN buffer data center in Puschino and scientific information center in Moscow. Still relevant the chanal equipment monitoring system, and storage systems, as well as the timely replacement of hardware and software upgrades, backups, and documentation of the network infrastructure.
NASA Astrophysics Data System (ADS)
Rothard, Hermann; Severin, Daniel; Trautmann, Christina
2015-12-01
The present volume contains the proceedings of the Ninth International Symposium on Swift Heavy Ions in Matter (SHIM). This conference was held in Darmstadt, from 18 to 21 May 2015. SHIM is a triennial series, which started about 25 years ago by a joint initiative of CIRIL - Caen and GSI - Darmstadt, with the aim of promoting fundamental and applied interdisciplinary research in the field of high-energy, heavy-ion interaction processes with matter. SHIM was successively organized in Caen (1989), Bensheim (1992), Caen (1995), Berlin (1998), Catania (2002), Aschaffenburg (2005), Lyon (2008), and Kyoto (2012). The conference attracts scientists from many different fields using high-energy heavy ions delivered by large accelerator facilities and characterized by strong and short electronic excitations.
The INTEGRAL scatterometer SPI
NASA Technical Reports Server (NTRS)
Mandrou, P.; Vedrenne, G.; Jean, P.; Kandel, B.; vonBallmoos, P.; Albernhe, F.; Lichti, G.; Schoenfelder, V.; Diehl, R.; Georgii, R.;
1997-01-01
The INTErnational Gamma Ray Astrophysics Laboratory (INTEGRAL) mission's onboard spectrometer, the INTEGRAL spectrometer (SPI), is described. The SPI constitutes one of the four main mission instruments. It is optimized for detailed measurements of gamma ray lines and for the mapping of diffuse sources. It combines a coded aperture mask with an array of large volume, high purity germanium detectors. The detectors make precise measurements of the gamma ray energies over the 20 keV to 8 MeV range. The instrument's characteristics are described and the Monte Carlo simulation of its performance is outlined. It will be possible to study gamma ray emission from compact objects or line profiles with a high energy resolution and a high angular resolution.
Monitoring of changes in cluster structures in water under AC magnetic field
NASA Astrophysics Data System (ADS)
Usanov, A. D.; Ulyanov, S. S.; Ilyukhina, N. S.; Usanov, D. A.
2016-01-01
A fundamental possibility of visualizing cluster structures formed in distilled water by an optical method based on the analysis of dynamic speckle structures is demonstrated. It is shown for the first time that, in contrast to the existing concepts, water clusters can be rather large (up to 200 -m in size), and their lifetime is several tens of seconds. These clusters are found to have an internal spatially inhomogeneous structure, constantly changing in time. The properties of magnetized and non-magnetized water are found to differ significantly. In particular, the number of clusters formed in magnetized water is several times larger than that formed in the same volume of non-magnetized water.
Taliotis, Constantinos; Taibi, Emanuele; Howells, Mark; Rogner, Holger; Bazilian, Morgan; Welsch, Manuel
2017-10-01
The generation mix of Cyprus has been dominated by oil products for decades. In order to conform with European Union and international legislation, a transformation of the supply system is called for. Energy system models can facilitate energy planning into the future, but a large volume of data is required to populate such models. The present data article provides information on key modelling assumptions and input data adopted with the aim of representing the electricity supply system of Cyprus in a separate research article. Data in regards to renewable energy technoeconomic characteristics and investment cost projections, fossil fuel price projections, storage technology characteristics and system operation assumptions are described in this article.
Savina, Irina N.; Ingavle, Ganesh C.; Cundy, Andrew B.; Mikhalovsky, Sergey V.
2016-01-01
The development of bulk, three-dimensional (3D), macroporous polymers with high permeability, large surface area and large volume is highly desirable for a range of applications in the biomedical, biotechnological and environmental areas. The experimental techniques currently used are limited to the production of small size and volume cryogel material. In this work we propose a novel, versatile, simple and reproducible method for the synthesis of large volume porous polymer hydrogels by cryogelation. By controlling the freezing process of the reagent/polymer solution, large-scale 3D macroporous gels with wide interconnected pores (up to 200 μm in diameter) and large accessible surface area have been synthesized. For the first time, macroporous gels (of up to 400 ml bulk volume) with controlled porous structure were manufactured, with potential for scale up to much larger gel dimensions. This method can be used for production of novel 3D multi-component macroporous composite materials with a uniform distribution of embedded particles. The proposed method provides better control of freezing conditions and thus overcomes existing drawbacks limiting production of large gel-based devices and matrices. The proposed method could serve as a new design concept for functional 3D macroporous gels and composites preparation for biomedical, biotechnological and environmental applications. PMID:26883390
Novel diamond cells for neutron diffraction using multi-carat CVD anvils.
Boehler, R; Molaison, J J; Haberl, B
2017-08-01
Traditionally, neutron diffraction at high pressure has been severely limited in pressure because low neutron flux required large sample volumes and therefore large volume presses. At the high-flux Spallation Neutron Source at the Oak Ridge National Laboratory, we have developed new, large-volume diamond anvil cells for neutron diffraction. The main features of these cells are multi-carat, single crystal chemical vapor deposition diamonds, very large diffraction apertures, and gas membranes to accommodate pressure stability, especially upon cooling. A new cell has been tested for diffraction up to 40 GPa with an unprecedented sample volume of ∼0.15 mm 3 . High quality spectra were obtained in 1 h for crystalline Ni and in ∼8 h for disordered glassy carbon. These new techniques will open the way for routine megabar neutron diffraction experiments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parthipun, A. A., E-mail: aneeta@hotmail.co.uk; Taylor, J.; Manyonda, I.
The purpose of this study was to determine whether there is a correlation between large uterine fibroid diameter, uterine volume, number of vials of embolic agent used and risk of complications from uterine artery embolisation (UAE). This was a prospective study involving 121 patients undergoing UAE embolisation for symptomatic uterine fibroids at a single institution. Patients were grouped according to diameter of largest fibroid and uterine volume. Results were also stratified according to the number of vials of embolic agent used and rate of complications. No statistical difference in complication rate was demonstrated between the two groups according to diametermore » of the largest fibroid (large fibroids were classified as {>=}10 cm; Fisher's exact test P = 1.00), and no statistical difference in complication rate was demonstrated according to uterine volume (large uterine volume was defined as {>=}750 cm{sup 3}; Fisher's exact test P = 0.70). 84 of the 121 patients had documentation of the number of vials used during the procedure. Patients were divided into two groups, with {>=}4 used defined as a large number of embolic agent. There was no statistical difference between these two groups and no associated increased risk of developing complications. This study showed no increased incidence of complications in women with large-diameter fibroids or uterine volumes as defined. In addition, there was no evidence of increased complications according to quantity of embolic material used. Therefore, UAE should be offered to women with large fibroids and uterine volumes.« less
Teaching International Politics in High School.
ERIC Educational Resources Information Center
English, Raymond, Ed.
Approaches to teaching about international politics and avenues to peace should be realistic and pragmatic rather than based on generalities about global education and peace education. This volume contains essays on international economic relations, cultural and linguistic understanding, and the conflict of ideologies and value systems in…
The Routledge International Handbook of Critical Education
ERIC Educational Resources Information Center
Apple, Michael W., Ed.; Au, Wayne, Ed.; Gandin, Luis Armando, Ed.
2011-01-01
"The Routledge International Handbook of Critical Education" is the first authoritative reference work to provide an international analysis of the relationship between power, knowledge, education, and schooling. Rather than focusing solely on questions of how we teach efficiently and effectively, contributors to this volume push further…
Modeling Antarctic Subglacial Lake Filling and Drainage Cycles
NASA Technical Reports Server (NTRS)
Dow, Christine F.; Werder, Mauro A.; Nowicki, Sophie; Walker, Ryan T.
2016-01-01
The growth and drainage of active subglacial lakes in Antarctica has previously been inferred from analysis of ice surface altimetry data. We use a subglacial hydrology model applied to a synthetic Antarctic ice stream to examine internal controls on the filling and drainage of subglacial lakes. Our model outputs suggest that the highly constricted subglacial environment of our idealized ice stream, combined with relatively high rates of water flow funneled from a large catchment, can combine to create a system exhibiting slow-moving pressure waves. Over a period of years, the accumulation of water in the ice stream onset region results in a buildup of pressure creating temporary channels, which then evacuate the excess water. This increased flux of water beneath the ice stream drives lake growth. As the water body builds up, it steepens the hydraulic gradient out of the overdeepened lake basin and allows greater flux. Eventually this flux is large enough to melt channels that cause the lake to drain. Lake drainage also depends on the internal hydrological development in the wider system and therefore does not directly correspond to a particular water volume or depth. This creates a highly temporally and spatially variable system, which is of interest for assessing the importance of subglacial lakes in ice stream hydrology and dynamics.
Cermák, Jan; Kucera, Jiri; Bauerle, William L; Phillips, Nathan; Hinckley, Thomas M
2007-02-01
Diurnal and seasonal tree water storage was studied in three large Douglas-fir (Pseudotsuga menziesii [Mirb.] Franco) trees at the Wind River Canopy Crane Research site. Changes in water storage were based on measurements of sap flow and changes in stem volume and tissue water content at different heights in the stem and branches. We measured sap flow by two variants of the heat balance method (with internal heating in stems and external heating in branches), stem volume with electronic dendrometers, and tissue water content gravimetrically. Water storage was calculated from the differences in diurnal courses of sap flow at different heights and their integration. Old-growth Douglas-fir trees contained large amounts of free water: stem sapwood was the most important storage site, followed by stem phloem, branch sapwood, branch phloem and needles. There were significant time shifts (minutes to hours) between sap flow measured at different positions within the transport system (i.e., stem base to shoot tip), suggesting a highly elastic transport system. On selected fine days between late July and early October, when daily transpiration ranged from 150 to 300 liters, the quantity of stored water used daily ranged from 25 to 55 liters, i.e., about 20% of daily total sap flow. The greatest amount of this stored water came from the lower stem; however, proportionally more water was removed from the upper parts of the tree relative to their water storage capacity. In addition to lags in sap flow from one point in the hydrolic pathway to another, the withdrawal and replacement of stored water was reflected in changes in stem volume. When point-to-point lags in sap flow (minutes to hours near the top and stem base, respectively) were considered, there was a strong linear relationship between stem volume changes and transpiration. Volume changes of the whole tree were small (equivalent to 14% of the total daily use of stored water) indicating that most stored water came from the stem and from its inelastic (sapwood) tissues. Whole tree transpiration can be maintained with stored water for about a week, but it can be maintained with stored water from the upper crown alone for no more than a few hours.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, L; Dong, P; Larson, D
Purpose: To investigate a new modulated beam orientation optimization (MBOO) approach maximizing treatment planning quality for the state-of-the-art flattening filter free (FFF) beam that has enabled rapid treatments of multiple brain targets. Methods: MBOO selects and optimizes a large number of intensity-modulated beams (400 or more) from all accessible beam angles surrounding a patient’s skull. The optimization algorithm was implemented on a standalone system that interfaced with the 3D Dicom images and structure sets. A standard published data set that consisted of 1 to 12 metastatic brain tumor combinations was selected for MBOO planning. The planning results from various coplanarmore » and non-coplanar configurations via MBOO were then compared with the results obtained from a clinical volume modulated arc therapy (VMAT) delivery system (Truebeam RapidArc, Varian Oncology). Results: When planning a few number of targets (n<4), MBOO produced results equivalent to non-coplanar multi-arc VMAT planning in terms of target volume coverage and normal tissue sparing. For example, the 12-Gy and 4-Gy normal brain volumes for the 3-target plans differed by less than 1 mL ( 3.0 mLvs 3.8 mL; and 35.2 mL vs 36.3 mL, respectively) for MBOO versus VMAT. However, when planning a larger number of targets (n≥4), MBOO significantly reduced the dose to the normal brain as compared to VMAT, though the target volume coverage was equivalent. For example, the 12-Gy and 4-Gy normal brain volumes for the 12-target plans were 10.8 mL vs. 18.0 mL and 217.9 mL vs. 390.0 mL, respectively for the non-coplanar MBOO versus the non-coplanar VMAT treatment plans, yielding a reduction in volume of more than 60% for the case. Conclusion: MBOO is a unique approach for maximizing normal tissue sparing when treating a large number (n≥4) of brain tumors with FFF linear accelerators. Dr Ma and Dr Sahgal are currently on the board of international society of stereotactic radiosurgery. Dr Sahgal has received support for educational presentations from Elekta company.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Specht, Lena, E-mail: lena.specht@regionh.dk; Yahalom, Joachim; Illidge, Tim
2014-07-15
Radiation therapy (RT) is the most effective single modality for local control of Hodgkin lymphoma (HL) and an important component of therapy for many patients. These guidelines have been developed to address the use of RT in HL in the modern era of combined modality treatment. The role of reduced volumes and doses is addressed, integrating modern imaging with 3-dimensional (3D) planning and advanced techniques of treatment delivery. The previously applied extended field (EF) and original involved field (IF) techniques, which treated larger volumes based on nodal stations, have now been replaced by the use of limited volumes, based solelymore » on detectable nodal (and extranodal extension) involvement at presentation, using contrast-enhanced computed tomography, positron emission tomography/computed tomography, magnetic resonance imaging, or a combination of these techniques. The International Commission on Radiation Units and Measurements concepts of gross tumor volume, clinical target volume, internal target volume, and planning target volume are used for defining the targeted volumes. Newer treatment techniques, including intensity modulated radiation therapy, breath-hold, image guided radiation therapy, and 4-dimensional imaging, should be implemented when their use is expected to decrease significantly the risk for normal tissue damage while still achieving the primary goal of local tumor control. The highly conformal involved node radiation therapy (INRT), recently introduced for patients for whom optimal imaging is available, is explained. A new concept, involved site radiation therapy (ISRT), is introduced as the standard conformal therapy for the scenario, commonly encountered, wherein optimal imaging is not available. There is increasing evidence that RT doses used in the past are higher than necessary for disease control in this era of combined modality therapy. The use of INRT and of lower doses in early-stage HL is supported by available data. Although the use of ISRT has not yet been validated in a formal study, it is more conservative than INRT, accounting for suboptimal information and appropriately designed for safe local disease control. The goal of modern smaller field radiation therapy is to reduce both treatment volume and treatment dose while maintaining efficacy and minimizing acute and late sequelae. This review is a consensus of the International Lymphoma Radiation Oncology Group (ILROG) Steering Committee regarding the modern approach to RT in the treatment of HL, outlining a new concept of ISRT in which reduced treatment volumes are planned for the effective control of involved sites of HL. Nodal and extranodal non-Hodgkin lymphomas (NHL) are covered separately by ILROG guidelines.« less
Specht, Lena; Yahalom, Joachim; Illidge, Tim; Berthelsen, Anne Kiil; Constine, Louis S; Eich, Hans Theodor; Girinsky, Theodore; Hoppe, Richard T; Mauch, Peter; Mikhaeel, N George; Ng, Andrea
2014-07-15
Radiation therapy (RT) is the most effective single modality for local control of Hodgkin lymphoma (HL) and an important component of therapy for many patients. These guidelines have been developed to address the use of RT in HL in the modern era of combined modality treatment. The role of reduced volumes and doses is addressed, integrating modern imaging with 3-dimensional (3D) planning and advanced techniques of treatment delivery. The previously applied extended field (EF) and original involved field (IF) techniques, which treated larger volumes based on nodal stations, have now been replaced by the use of limited volumes, based solely on detectable nodal (and extranodal extension) involvement at presentation, using contrast-enhanced computed tomography, positron emission tomography/computed tomography, magnetic resonance imaging, or a combination of these techniques. The International Commission on Radiation Units and Measurements concepts of gross tumor volume, clinical target volume, internal target volume, and planning target volume are used for defining the targeted volumes. Newer treatment techniques, including intensity modulated radiation therapy, breath-hold, image guided radiation therapy, and 4-dimensional imaging, should be implemented when their use is expected to decrease significantly the risk for normal tissue damage while still achieving the primary goal of local tumor control. The highly conformal involved node radiation therapy (INRT), recently introduced for patients for whom optimal imaging is available, is explained. A new concept, involved site radiation therapy (ISRT), is introduced as the standard conformal therapy for the scenario, commonly encountered, wherein optimal imaging is not available. There is increasing evidence that RT doses used in the past are higher than necessary for disease control in this era of combined modality therapy. The use of INRT and of lower doses in early-stage HL is supported by available data. Although the use of ISRT has not yet been validated in a formal study, it is more conservative than INRT, accounting for suboptimal information and appropriately designed for safe local disease control. The goal of modern smaller field radiation therapy is to reduce both treatment volume and treatment dose while maintaining efficacy and minimizing acute and late sequelae. This review is a consensus of the International Lymphoma Radiation Oncology Group (ILROG) Steering Committee regarding the modern approach to RT in the treatment of HL, outlining a new concept of ISRT in which reduced treatment volumes are planned for the effective control of involved sites of HL. Nodal and extranodal non-Hodgkin lymphomas (NHL) are covered separately by ILROG guidelines. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Ramachandran, R.; Murphy, K. J.; Baynes, K.; Lynnes, C.
2016-12-01
With the volume of Earth observation data expanding rapidly, cloud computing is quickly changing the way Earth observation data is processed, analyzed, and visualized. The cloud infrastructure provides the flexibility to scale up to large volumes of data and handle high velocity data streams efficiently. Having freely available Earth observation data collocated on a cloud infrastructure creates opportunities for innovation and value-added data re-use in ways unforeseen by the original data provider. These innovations spur new industries and applications and spawn new scientific pathways that were previously limited due to data volume and computational infrastructure issues. NASA, in collaboration with Amazon, Google, and Microsoft, have jointly developed a set of recommendations to enable efficient transfer of Earth observation data from existing data systems to a cloud computing infrastructure. The purpose of these recommendations is to provide guidelines against which all data providers can evaluate existing data systems and be used to improve any issues uncovered to enable efficient search, access, and use of large volumes of data. Additionally, these guidelines ensure that all cloud providers utilize a common methodology for bulk-downloading data from data providers thus preventing the data providers from building custom capabilities to meet the needs of individual cloud providers. The intent is to share these recommendations with other Federal agencies and organizations that serve Earth observation to enable efficient search, access, and use of large volumes of data. Additionally, the adoption of these recommendations will benefit data users interested in moving large volumes of data from data systems to any other location. These data users include the cloud providers, cloud users such as scientists, and other users working in a high performance computing environment who need to move large volumes of data.
Breast-volume displacement using an extended glandular flap for small dense breasts.
Ogawa, Tomoko; Hanamura, Noriko; Yamashita, Masako; Kimura, Hiroko; Kashikura, Yumi
2011-01-01
We defined the glandular flap including fat in the subclavicular area as an extended glandular flap, which has been used for breast-conserving reconstruction in the upper portion of the breast. Indication. The excision volume was 20% to 40% of the breast volume, and the breast density was dense. Surgical Technique. The upper edge of the breast at the subclavicular area was drawn in the standing position before surgery. After partial mastectomy, an extended glandular flap was made by freeing the breast from both the skin and the pectoralis fascia up to the preoperative marking in the subclavicular area. It is important to keep the perforators of the internal mammary artery and/or the branches of the lateral thoracic artery intact while making the flap. Results. Seventeen patients underwent remodeling using an extended glandular flap. The cosmetic results at 1 year after the operation: excellent in 11, good in 1, fair in 3, and poor in 2. All cases of unacceptable outcome except one were cases with complications, and more than 30% resection of moderate or large size breasts did not obtain an excellent result for long-term followup. Conclusion. This technique is useful for performing the breast-conserving reconstruction of small dense breasts.
A Local Net Volume Equation for Iowa
Jerold T. Hahn
1976-01-01
As a part of the 1974 Forest Survey of Iowa, the Station''s Forst Resources Evaluatioin Research Staff developed a merchantable tree volume equation and tables of coefficients for Iowa. They were developed for both board-foot (International ?-inch rule) and cubic foot volumes, for several species and species groups of growing-stock trees. The equation and...
Studies in Mathematics Education: The Teaching of Statistics, Volume 7.
ERIC Educational Resources Information Center
Morris, Robert, Ed.
This volume examines the teaching of statistics in the whole range of education, but concentrates on primary and secondary schools. It is based upon selected topics from the Second International Congress on Teaching Statistics (ICOTS 2), convened in Canada in August 1986. The contents of this volume divide broadly into four parts: statistics in…
The Oxford Handbook of Deaf Studies, Language, and Education, Volume 2
ERIC Educational Resources Information Center
Marschark, Marc, Ed.; Spencer, Patricia Elizabeth, Ed.
2010-01-01
"The Oxford Handbook of Deaf Studies, Language, and Education, Volume 2," is an updated edition of the landmark original volume. A range of international experts present a comprehensive overview of the field of deaf studies, language, and education. This area has grown dramatically over the past forty years. From work on the linguistics…
ERIC Educational Resources Information Center
Dongping, Yang, Ed.; Chungqing, Chai, Ed.
2010-01-01
The second volume of the English-language The China Educational Development Yearbook offers international scholars a glimpse into key issues in Chinese education today from the perspective of Chinese academics, practitioners, and applied researchers. An edited translation of the 2009 volume of the Chinese-language "Blue Book of…
ERIC Educational Resources Information Center
Urban Inst., Washington, DC.
This last of a three-volume report of a study done to assess the feasibility of large-scale, countercyclical public job creation covers the findings regarding the priorities among projects, indirect employment effects, skill imbalances, and administrative issues; and summarizes the overall findings, conclusions, and recommendations. (Volume 1,…
NASA Astrophysics Data System (ADS)
Kramer, R.; Cassola, V. F.; Khoury, H. J.; Vieira, J. W.; de Melo Lima, V. J.; Robson Brown, K.
2010-01-01
Female and male adult human phantoms, called FASH (Female Adult meSH) and MASH (Male Adult meSH), have been developed in the first part of this study using 3D animation software and anatomical atlases to replace the image-based FAX06 and the MAX06 voxel phantoms. 3D modelling methods allow for phantom development independent from medical images of patients, volunteers or cadavers. The second part of this study investigates the dosimetric implications for organ and tissue equivalent doses due to the anatomical differences between the new and the old phantoms. These differences are mainly caused by the supine position of human bodies during scanning in order to acquire digital images for voxel phantom development. Compared to an upright standing person, in image-based voxel phantoms organs are often coronally shifted towards the head and sometimes the sagittal diameter of the trunk is reduced by a gravitational change of the fat distribution. In addition, volumes of adipose and muscle tissue shielding internal organs are sometimes too small, because adaptation of organ volumes to ICRP-based organ masses often occurs at the expense of general soft tissues, such as adipose, muscle or unspecified soft tissue. These effects have dosimetric consequences, especially for partial body exposure, such as in x-ray diagnosis, but also for whole body external exposure and for internal exposure. Using the EGSnrc Monte Carlo code, internal and external exposure to photons and electrons has been simulated with both pairs of phantoms. The results show differences between organ and tissue equivalent doses for the upright standing FASH/MASH and the image-based supine FAX06/MAX06 phantoms of up to 80% for external exposure and up to 100% for internal exposure. Similar differences were found for external exposure between FASH/MASH and REGINA/REX, the reference voxel phantoms of the International Commission on Radiological Protection. Comparison of effective doses for external photon exposure showed good agreement between FASH/MASH and REGINA/REX, but large differences between FASH/MASH and the mesh-based RPI_AM and the RPI_AF phantoms, developed at the Rensselaer Polytechnic Institute (RPI).
Low emission internal combustion engine
Karaba, Albert M.
1979-01-01
A low emission, internal combustion compression ignition engine having a cylinder, a piston movable in the cylinder and a pre-combustion chamber communicating with the cylinder near the top thereof and in which low emissions of NO.sub.x are achieved by constructing the pre-combustion chamber to have a volume of between 70% and 85% of the combined pre-chamber and main combustion chamber volume when the piston is at top dead center and by variably controlling the initiation of fuel injection into the pre-combustion chamber.
High internal free volume compositions for low-k dielectric and other applications
NASA Technical Reports Server (NTRS)
Bouffard, Jean (Inventor); Swager, Timothy M. (Inventor)
2010-01-01
The present invention provides materials, devices, and methods involving new heterocyclic, shape-persistent monomeric units with internal free volume. In some cases, materials the present invention may comprise monomers, oligomers, or polymers that incorporate a heterocyclic, shape-persistent iptycene. The present invention may provide materials having low dielectric constants and improved stability at high operating temperatures due to the electron-poor character of materials. In addition, compositions of the invention may be easily synthesized and readily modified to suit a particular application.
Adapting an Agent-Based Model of Socio-Technical Systems to Analyze System and Security Failures
2016-05-09
statistically significant amount, which it did with a p-valueɘ.0003 on a simulation of 3125 iterations; the data is shown in the Delegation 1 column of...Blackout metric to a statistically significant amount, with a p-valueɘ.0003 on a simulation of 3125 iterations; the data is shown in the Delegation 2...Proceedings of the 9th International Conference on Autonomous Agents and Multiagent Systems: volume 1-Volume 1, pp. 1007- 1014 . International Foundation
Consequence assessment of large rock slope failures in Norway
NASA Astrophysics Data System (ADS)
Oppikofer, Thierry; Hermanns, Reginald L.; Horton, Pascal; Sandøy, Gro; Roberts, Nicholas J.; Jaboyedoff, Michel; Böhme, Martina; Yugsi Molina, Freddy X.
2014-05-01
Steep glacially carved valleys and fjords in Norway are prone to many landslide types, including large rockslides, rockfalls, and debris flows. Large rockslides and their secondary effects (rockslide-triggered displacement waves, inundation behind landslide dams and outburst floods from failure of landslide dams) pose a significant hazard to the population living in the valleys and along the fjords shoreline. The Geological Survey of Norway performs systematic mapping of unstable rock slopes in Norway and has detected more than 230 unstable slopes with significant postglacial deformation. This large number necessitates prioritisation of follow-up activities, such as more detailed investigations, periodic displacement measurements, continuous monitoring and early-warning systems. Prioritisation is achieved through a hazard and risk classification system, which has been developed by a panel of international and Norwegian experts (www.ngu.no/en-gb/hm/Publications/Reports/2012/2012-029). The risk classification system combines a qualitative hazard assessment with a consequences assessment focusing on potential life losses. The hazard assessment is based on a series of nine geomorphological, engineering geological and structural criteria, as well as displacement rates, past events and other signs of activity. We present a method for consequence assessment comprising four main steps: 1. computation of the volume of the unstable rock slope; 2. run-out assessment based on the volume-dependent angle of reach (Fahrböschung) or detailed numerical run-out modelling; 3. assessment of possible displacement wave propagation and run-up based on empirical relations or modelling in 2D or 3D; and 4. estimation of the number of persons exposed to rock avalanches or displacement waves. Volume computation of an unstable rock slope is based on the sloping local base level technique, which uses a digital elevation model to create a second-order curved surface between the mapped extent of the unstable rock slope. This surface represents the possible basal sliding surface of an unstable rock slope. The elevation difference between this surface and the topographic surface estimates the volume of the unstable rock slope. A tool has been developed for the present study to adapt the curvature parameters of the computed surface to local geological and structural conditions. The obtained volume is then used to define the angle of reach of a possible rock avalanche from the unstable rock slope by using empirical derived values of angle of reach vs. volume relations. Run-out area is calculated using FlowR; the software is widely used for run-out assessment of debris flows and is adapted here for assessment of rock avalanches, including their potential to ascend opposing slopes. Under certain conditions, more sophisticated and complex numerical run-out models are also used. For rock avalanches with potential to reach a fjord or a lake the propagation and run-up area of triggered displacement waves is assessed. Empirical relations of wave run-up height as a function of rock avalanche volume and distance from impact location are derived from a national and international inventory of landslide-triggered displacement waves. These empirical relations are used in first-level hazard assessment and where necessary, followed by 2D or 3D displacement wave modelling. Finally, the population exposed in the rock avalanche run-out area and in the run-up area of a possible displacement wave is assessed taking into account different population groups: inhabitants, persons in critical infrastructure (hospitals and other emergency services), persons in schools and kindergartens, persons at work or in shops, tourists, persons on ferries and so on. Exposure levels are defined for each population group and vulnerability values are set for the rock avalanche run-out area (100%) and the run-up area of a possible displacement wave (70%). Finally, the total number of persons within the hazard area is calculated taking into account exposure and vulnerability. The method for consequence assessment is currently tested through several case studies in Norway and, thereafter, applied to all unstable rock slopes in the country to assess their risk level. Follow-up activities (detailed investigations, periodic displacement measurements or continuous monitoring and early-warning systems) can then be prioritized based on the risk level and with a standard approach for whole Norway.
Giant-geode endowment of tumuli in the Veia Alta flow, Ametista do Sul
NASA Astrophysics Data System (ADS)
Hartmann, L. A.; Pertille, J.; Duarte, L. C.
2017-08-01
Tumuli are a common feature of pahoehoe basaltic flows, interspersed with pits, and furnished the necessary volume of rock in the Paraná volcanic province for hydrothermal alteration and ballooning to form large cavities (1-2 m common). Filling by amethyst and other minerals resulted in the largest world deposit of geodes, Ametista do Sul. The flat-lying fracture positioned 1 m below the 2-3 m thick geodic level crosses the plateau and is a major guide for exploration and gallery opening. The geodes are limited on the top by the platy joint layer, which is covered by an auto-breccia with undulating lower limit. This wave mimicks and is internal to the structure of tumuli and pits at the surface. This field-oriented survey of galleries selected out of 300 active mines resulted in the description of the internal structure of the remarkable Veia Alta pahoehoe flow, in addition to observations in Uruguay.
NASA Technical Reports Server (NTRS)
Matty, Christopher M.; Cover, John M.
2009-01-01
The International Space Station (ISS) represents a largely closed-system habitable volume which requires active control of atmospheric constituents, including removal of exhaled Carbon Dioxide (CO2). The ISS provides a unique opportunity to observe system requirements for (CO2) removal. CO2 removal is managed by the Carbon Dioxide Removal Assembly (CDRA) aboard the US segment of ISS and by Lithium Hydroxide (LiOH) aboard the Space Shuttle (STS). While the ISS and STS are docked, various methods are used to balance the CO2 levels between the two vehicles, including mechanical air handling and management of general crew locations. Over the course of ISS operation, several unexpected anomalies have occurred which have required troubleshooting, including possible compromised performance of the CDRA and LiOH systems, and possible imbalance in CO2 levels between the ISS and STS while docked. This paper will cover efforts to troubleshoot the CO2 removal systems aboard the ISS and docked STS.
NASA Astrophysics Data System (ADS)
Hruszkewycz, Stephan; Cha, Wonsuk; Ulvestad, Andrew; Fuoss, Paul; Heremans, F. Joseph; Harder, Ross; Andrich, Paolo; Anderson, Christopher; Awschalom, David
The nitrogen-vacancy center in diamond has attracted considerable attention for nanoscale sensing due to unique optical and spin properties. Many of these applications require diamond nanoparticles which contain large amounts of residual strain due to the detonation or milling process used in their fabrication. Here, we present experimental, in-situ observations of changes in morphology and internal strain state of commercial nanodiamonds during high-temperature annealing using Bragg coherent diffraction imaging to reconstruct a strain-sensitive 3D image of individual sub-micron-sized crystals. We find minimal structural changes to the nanodiamonds at temperatures less than 650 C, and that at higher temperatures up to 750 C, the diamond-structured volume fraction of nanocrystals tend to shrink. The degree of internal lattice distortions within nanodiamond particles also decreases during the anneal. Our findings potentially enable the design of efficient processing of commercial nanodiamonds into viable materials suitable for device design. We acknowledge support from U.S. DOE, Office of Science, BES, MSE.
Targeted opportunities to address the climate-trade dilemma in China
NASA Astrophysics Data System (ADS)
Liu, Zhu; Davis, Steven J.; Feng, Kuishuang; Hubacek, Klaus; Liang, Sai; Anadon, Laura Diaz; Chen, Bin; Liu, Jingru; Yan, Jinyue; Guan, Dabo
2016-02-01
International trade has become the fastest growing driver of global carbon emissions, with large quantities of emissions embodied in exports from emerging economies. International trade with emerging economies poses a dilemma for climate and trade policy: to the extent emerging markets have comparative advantages in manufacturing, such trade is economically efficient and desirable. However, if carbon-intensive manufacturing in emerging countries such as China entails drastically more CO2 emissions than making the same product elsewhere, then trade increases global CO2 emissions. Here we show that the emissions embodied in Chinese exports, which are larger than the annual emissions of Japan or Germany, are primarily the result of China’s coal-based energy mix and the very high emissions intensity (emission per unit of economic value) in a few provinces and industry sectors. Exports from these provinces and sectors therefore represent targeted opportunities to address the climate-trade dilemma by either improving production technologies and decarbonizing the underlying energy systems or else reducing trade volumes.
Small Gas Turbine Combustor Primary Zone Study
NASA Technical Reports Server (NTRS)
Sullivan, R. E.; Young, E. R.; Miles, G. A.; Williams, J. R.
1983-01-01
A development process is described which consists of design, fabrication, and preliminary test evaluations of three approaches to internal aerodynamic primary zone flow patterns: (1) conventional double vortex swirl stabilization; (2) reverse flow swirl stabilization; and (3) large single vortex flow system. Each concept incorporates special design features aimed at extending the performance capability of the small engine combustor. Since inherent geometry of these combustors result in small combustion zone height and high surface area to volume ratio, design features focus on internal aerodynamics, fuel placement, and advanced cooling. The combustors are evaluated on a full scale annular combustor rig. A correlation of the primary zone performance with the overall performance is accomplished using three intrusion type gas sampling probes located at the exit of the primary zone section. Empirical and numerical methods are used for designing and predicting the performance of the three combustor concepts and their subsequent modifications. The calibration of analytical procedures with actual test results permits an updating of the analytical design techniques applicable to small reverse flow annular combustors.
NASA Astrophysics Data System (ADS)
Skrętowicz, Maria; Sroka, Zbigniew
2017-11-01
The depletion of the fossil fuels resources, significant increase of the air pollution caused by the use of internal combustion engines, and emission of carbon dioxide which is responsible for the greenhouse effect escalates the development of vehicle's alternative drive systems. Generally, the emphasis is given to the alternative fuels (natural gas CNG, mixture of propane-butane gases LPG, hydrogen, alcohol fuels, biofuels) and hybrid or electric vehicles. Roads between large industrial and commercial centres, i.e. Wroclaw - Dresden - Prague, are used mainly by heavy-duty vehicles. Consequently, the contribution of the road transport to the ecological threat in this realm is significant. The objectives of this research were the assessment of the traffic volume and emission rate of exhaust gases caused by heavy-duty vehicles on the analysed roads and evaluation of the possibility of using existing and alternative drive systems in vehicles driving on the roads in the analysed region.
A Wireless Self-Powered Urinary Incontinence Sensor System
NASA Astrophysics Data System (ADS)
Tanaka, Ami; Utsunomiya, Fumiyasu; Douseki, Takakuni
A self-powered urinary incontinence sensor system consisting of a urine-activated coin battery and a wireless transmitter has been developed as an application for wireless biosensor networks. The urine-activated battery makes possible both the sensing of urine leakage and self-powered operation. An intermittent power-supply circuit that uses an electric double-layer capacitor (EDLC) with a small internal resistance suppresses the supply voltage drop due to the large internal resistance of the battery. This circuit and a 1-V surface acoustic wave (SAW) oscillator reduce the power dissipation of a wireless transmitter. The SAW oscillator quickly responds to the on-off control of the power supply, which is suitable for intermittent operation. To verify the effectiveness of the circuit scheme, the authors fabricated a prototype sensor system. When the volume of urine is 0.2 ml, the battery outputs a voltage of over 1.3 V; and the sensor system can transmit signals over a distance of 5 m.
Hookey, Lawrence C; Depew, William T; Vanner, Stephen J
2006-01-01
INTRODUCTION The effectiveness of polyethylene glycol solutions (PEG) for colon cleansing is often limited by the inability of patients to drink adequate portions of the 4 L solution. The aim of the present study was to determine whether a reduced volume of PEG combined with stimulant laxatives would be better tolerated and as or more effective than the standard dose. METHODS Patients undergoing outpatient colonoscopy were randomly assigned to receive either low-volume PEG plus sennosides (120 mg oral sennosides syrup followed by 2 L PEG) or the standard volume preparation (4 L PEG). The subjects rated the tolerability of the preparations and their symptoms. Colonoscopists were blind to the colonic cleansing preparation and graded the cleansing efficacy using a validated tool (the Ottawa scale). RESULTS The low-volume PEG plus sennosides preparation was significantly better tolerated than the standard large volume PEG (P<0.001) but was less efficacious (P=0.03). Thirty-eight per cent of patients in the large volume PEG group were unable to finish the preparation, compared with only 6% in the reduced volume group. There were no adverse events reported. CONCLUSIONS Although the low-volume PEG plus sennosides preparation was better tolerated, it was not as effective as standard large-volume PEG. However, in view of the significant difference in tolerance, further research investigating possible improvements in the reduced-volume regimen seems warranted. PMID:16482236
International Travel by Speakers of Esperanto. Esperanto Documents, New Series, No. 9A.
ERIC Educational Resources Information Center
Tyblewski, Tyburcjusz
This volume considers the value of Esperanto in relation to international tourism, and the characteristics of Esperantist tourists. Esperanto is seen as a solution to problems of language in international relations in general, and thus to international travel as well. The following are some of the general characteristics of the majority of…
ERIC Educational Resources Information Center
Blazer, Christie
2011-01-01
This Research Brief summarizes the performance of M-DCPS students participating in the International Baccalaureate (IB) and Cambridge Advanced International Certificate of Education (AICE) programs. Outcome data are provided for the eight M-DCPS schools offering the two programs and corresponding examinations. Participation in international…
Visualizing astronomy data using VRML
NASA Astrophysics Data System (ADS)
Beeson, Brett; Lancaster, Michael; Barnes, David G.; Bourke, Paul D.; Rixon, Guy T.
2004-09-01
Visualisation is a powerful tool for understanding the large data sets typical of astronomical surveys and can reveal unsuspected relationships and anomalous regions of parameter space which may be difficult to find programatically. Visualisation is a classic information technology for optimising scientific return. We are developing a number of generic on-line visualisation tools as a component of the Australian Virtual Observatory project. The tools will be deployed within the framework of the International Virtual Observatory Alliance (IVOA), and follow agreed-upon standards to make them accessible by other programs and people. We and our IVOA partners plan to utilise new information technologies (such as grid computing and web services) to advance the scientific return of existing and future instrumentation. Here we present a new tool - VOlume - which visualises point data. Visualisation of astronomical data normally requires the local installation of complex software, the downloading of potentially large datasets, and very often time-consuming and tedious data format conversions. VOlume enables the astronomer to visualise data using just a web browser and plug-in. This is achieved using IVOA standards which allow us to pass data between Web Services, Java Servlet Technology and Common Gateway Interface programs. Data from a catalogue server can be streamed in eXtensible Mark-up Language format to a servlet which produces Virtual Reality Modeling Language output. The user selects elements of the catalogue to map to geometry and then visualises the result in a browser plug-in such as Cortona or FreeWRL. Other than requiring an input VOTable format file, VOlume is very general. While its major use will likely be to display and explore astronomical source catalogues, it can easily render other important parameter fields such as the sky and redshift coverage of proposed surveys or the sampling of the visibility plane by a rotation-synthesis interferometer.
Titan2D simulations of dome-collapse pyroclastic flows for crisis assessments on Montserrat
NASA Astrophysics Data System (ADS)
Widiwijayanti, C.; Voight, B.; Hidayat, D.; Patra, A.; Pitman, E.
2010-12-01
The Soufriere Hills Volcano (SHV), Montserrat, has experienced numerous episodes of lava dome collapses since 1995. Collapse volumes range from small rockfalls to major dome collapses (as much as ~200 M m3). Problems arise in hazards mitigation, particularly in zoning for populated areas. Determining the likely extent of flowage deposits in various scenarios is important for hazards zonation, provision of advice by scientists, and decision making by public officials. Towards resolution of this issue we have tested the TITAN2D code, calibrated parameters for an SHV database, and using updated topography have provided flowage maps for various scenarios and volume classes from SHV, for use in hazards assessments. TITAN2D is a map plane (depth averaged) simulator of granular flow and yields mass distributions over a DEM. Two Coulomb frictional parameters (basal and internal frictions) and initial source conditions (volume, source location, and source geometry) of single or multiple pulses in a dome-collapse type event control behavior of the flow. Flow kinematics are captured, so that the dynamics of flow can be examined spatially from frame to frame, or as a movie. Our hazard maps include not only the final deposit, but also areas inundated by moving debris prior to deposition. Simulations from TITAN2D were important for analysis of crises in the period 2007-2010. They showed that any very large mass released on the north slope would be strongly partitioned by local topography, and thus it was doubtful that flows of very large size (>20 M m3) could be generated in the Belham River drainage. This partitioning effect limited runout toward populated areas. These effects were interpreted to greatly reduce the down-valley risk of ash-cloud surges.
Methods and computer readable medium for improved radiotherapy dosimetry planning
Wessol, Daniel E.; Frandsen, Michael W.; Wheeler, Floyd J.; Nigg, David W.
2005-11-15
Methods and computer readable media are disclosed for ultimately developing a dosimetry plan for a treatment volume irradiated during radiation therapy with a radiation source concentrated internally within a patient or incident from an external beam. The dosimetry plan is available in near "real-time" because of the novel geometric model construction of the treatment volume which in turn allows for rapid calculations to be performed for simulated movements of particles along particle tracks therethrough. The particles are exemplary representations of alpha, beta or gamma emissions emanating from an internal radiation source during various radiotherapies, such as brachytherapy or targeted radionuclide therapy, or they are exemplary representations of high-energy photons, electrons, protons or other ionizing particles incident on the treatment volume from an external source. In a preferred embodiment, a medical image of a treatment volume irradiated during radiotherapy having a plurality of pixels of information is obtained.
van Lieverloo, J Hein M; Hoogenboezem, Wim; Veenendaal, Gerrit; van der Kooij, Dick
2012-10-15
A survey of invertebrates in drinking water from treatment works, internal taps and hydrants on mains was carried out by almost all water companies in the Netherlands from September 1993 to August 1995. Aquatic sow bugs (Asellidae, 1-12 mm) and oligochaeta worms (Oligochaeta, 1-100 mm), both known to have caused rare though embarrassing consumer complaints, were found to form 98% of the mean biomass in water flushed from mains. Their numbers in the mains water ranged up to 1500 (mean 37) Asellidae m(-3) and up to 9900 (mean 135) Oligochaeta m(-3). Smaller crustaceans (0.5-2 mm) dominated the numbers in water from mains. e.g. water fleas (Cladocera and Copepoda up to 14,000 m(-3)). Common invertebrates in treated water and in tap water were Rotifera (<1 mm) and nematode worms (Nematoda, <2 mm). No Asellidae, large Oligochaeta (>5 mm) or other large invertebrates were found in 1560 samples of 200 l treated water or tap water. Large variations in invertebrate abundance were found within and between distribution systems. Of the variability of mean biomass in mains per system, 55%, 60% and 63% could statistically be explained by differences in the Biofilm Formation Rate, non-particulate organic matter and the permanganate index of the treated water of the treatment works respectively. A similar correlation was found between mean invertebrate biomass and mean sediment volumes in the distribution systems (R(2) = 52%). Copyright © 2012 Elsevier Ltd. All rights reserved.
Tsunoda, Tomonori; Kachi, Naoki; Suzuki, Jun-Ichirou
2014-01-01
We examined how the volume and temporal heterogeneity of water supply changed the vertical distribution and mortality of a belowground herbivore, and consequently affected plant biomass. Plantago lanceolata (Plantaginaceae) seedlings were grown at one per pot under different combinations of water volume (large or small volume) and heterogeneity (homogeneous water conditions, watered every day; heterogeneous conditions, watered every 4 days) in the presence or absence of a larva of the belowground herbivorous insect, Anomala cuprea (Coleoptera: Scarabaeidae). The larva was confined in different vertical distributions to top feeding zone (top treatment), middle feeding zone (middle treatment), or bottom feeding zone (bottom treatment); alternatively no larva was introduced (control treatment) or larval movement was not confined (free treatment). Three-way interaction between water volume, heterogeneity, and the herbivore significantly affected plant biomass. With a large water volume, plant biomass was lower in free treatment than in control treatment regardless of heterogeneity. Plant biomass in free treatment was as low as in top treatment. With a small water volume and in free treatment, plant biomass was low (similar to that under top treatment) under homogeneous water conditions but high under heterogeneous ones (similar to that under middle or bottom treatment). Therefore, there was little effect of belowground herbivory on plant growth under heterogeneous water conditions. In other watering regimes, herbivores would be distributed in the shallow soil and reduced root biomass. Herbivore mortality was high with homogeneous application of a large volume or heterogeneous application of a small water volume. Under the large water volume, plant biomass was high in pots in which the herbivore had died. Thus, the combinations of water volume and heterogeneity affected plant growth via the change of a belowground herbivore.
The proceedings document presentations at the International Conference on Municipal Waste Combustion (MWC), held on April 11-14, 1989, in Hollywood, Florida. The objective of the Conference was to provide an effective international forum for the exchange and transfer of informati...
The View Finder: International Perspectives on Special Education Technology. Volume 3.
ERIC Educational Resources Information Center
Edyburn, Dave L.; And Others
The four articles in this monograph present issues in the application of technology to special education from an international perspective. In the first chapter, "Augmentative and Alternative Communication Systems--Computer Applications for Individuals with Disabilities: An International Perspective," Richard Cardinali and George McMurdo…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Majewski, Wojciech, E-mail: wmajewski1@poczta.onet.p; Wesolowska, Iwona; Urbanczyk, Hubert
2009-12-01
Purpose: To estimate bladder movements and changes in dose distribution in the bladder and surrounding tissues associated with changes in bladder filling and to estimate the internal treatment margins. Methods and Materials: A total of 16 patients with bladder cancer underwent planning computed tomography scans with 80- and 150-mL bladder volumes. The bladder displacements associated with the change in volume were measured. Each patient had treatment plans constructed for a 'partially empty' (80 mL) and a 'partially full' (150 mL) bladder. An additional plan was constructed for tumor irradiation alone. A subsequent 9 patients underwent sequential weekly computed tomography scanningmore » during radiotherapy to verify the bladder movements and estimate the internal margins. Results: Bladder movements were mainly observed cranially, and the estimated internal margins were nonuniform and largest (>2 cm) anteriorly and cranially. The dose distribution in the bladder worsened if the bladder increased in volume: 70% of patients (11 of 16) would have had bladder underdosed to <95% of the prescribed dose. The dose distribution in the rectum and intestines was better with a 'partially empty' bladder (volume that received >70%, 80%, and 90% of the prescribed dose was 23%, 20%, and 15% for the rectum and 162, 144, 123 cm{sup 3} for the intestines, respectively) than with a 'partially full' bladder (volume that received >70%, 80%, and 90% of the prescribed dose was 28%, 24%, and 18% for the rectum and 180, 158, 136 cm{sup 3} for the intestines, respectively). The change in bladder filling during RT was significant for the dose distribution in the intestines. Tumor irradiation alone was significantly better than whole bladder irradiation in terms of organ sparing. Conclusion: The displacements of the bladder due to volume changes were mainly related to the upper wall. The internal margins should be nonuniform, with the largest margins cranially and anteriorly. The changes in bladder filling during RT could influence the dose distribution in the bladder and intestines. The dose distribution in the rectum and bowel was slightly better with a 'partially empty' than with a 'full' bladder.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, Ryan; Han Gang; Sarangkasiri, Siriporn
2013-01-01
Purpose: To report clinical and dosimetric factors predictive of radiation pneumonitis (RP) in patients receiving lung stereotactic body radiation therapy (SBRT) from a series of 240 patients. Methods and Materials: Of the 297 isocenters treating 263 patients, 240 patients (n=263 isocenters) had evaluable information regarding RP. Age, gender, current smoking status and pack-years, O{sub 2} use, Charlson Comorbidity Index, prior lung radiation therapy (yes/no), dose/fractionation, V{sub 5}, V{sub 13}, V{sub 20}, V{sub prescription}, mean lung dose, planning target volume (PTV), total lung volume, and PTV/lung volume ratio were recorded. Results: Twenty-nine patients (11.0%) developed symptomatic pneumonitis (26 grade 2, 3more » grade 3). The mean V{sub 20} was 6.5% (range, 0.4%-20.2%), and the average mean lung dose was 5.03 Gy (0.547-12.2 Gy). In univariable analysis female gender (P=.0257) and Charlson Comorbidity index (P=.0366) were significantly predictive of RP. Among dosimetric parameters, V{sub 5} (P=.0186), V{sub 13} (P=.0438), and V{sub prescription} (where dose = 60 Gy) (P=.0128) were significant. There was only a trend toward significance for V{sub 20} (P=.0610). Planning target volume/normal lung volume ratio was highly significant (P=.0024). In multivariable analysis the clinical factors of female gender, pack-years smoking, and larger gross internal tumor volume and PTV were predictive (P=.0094, .0312, .0364, and .052, respectively), but no dosimetric factors were significant. Conclusions: Rate of symptomatic RP was 11%. Our mean lung dose was <600 cGy in most cases and V20 <10%. In univariable analysis, dosimetric factors were predictive, while tumor size (or tumor/lung volume ratio) played a role in multivariable and univariable and analysis, respectively.« less
Syringe injectable electronics
Hong, Guosong; Zhou, Tao; Jin, Lihua; Duvvuri, Madhavi; Jiang, Zhe; Kruskal, Peter; Xie, Chong; Suo, Zhigang; Fang, Ying; Lieber, Charles M.
2015-01-01
Seamless and minimally-invasive three-dimensional (3D) interpenetration of electronics within artificial or natural structures could allow for continuous monitoring and manipulation of their properties. Flexible electronics provide a means for conforming electronics to non-planar surfaces, yet targeted delivery of flexible electronics to internal regions remains difficult. Here, we overcome this challenge by demonstrating syringe injection and subsequent unfolding of submicrometer-thick, centimeter-scale macroporous mesh electronics through needles with a diameter as small as 100 micrometers. Our results show that electronic components can be injected into man-made and biological cavities, as well as dense gels and tissue, with > 90% device yield. We demonstrate several applications of syringe injectable electronics as a general approach for interpenetrating flexible electronics with 3D structures, including (i) monitoring of internal mechanical strains in polymer cavities, (ii) tight integration and low chronic immunoreactivity with several distinct regions of the brain, and (iii) in vivo multiplexed neural recording. Moreover, syringe injection enables delivery of flexible electronics through a rigid shell, delivery of large volume flexible electronics that can fill internal cavities and co-injection of electronics with other materials into host structures, opening up unique applications for flexible electronics. PMID:26053995
Syringe-injectable electronics.
Liu, Jia; Fu, Tian-Ming; Cheng, Zengguang; Hong, Guosong; Zhou, Tao; Jin, Lihua; Duvvuri, Madhavi; Jiang, Zhe; Kruskal, Peter; Xie, Chong; Suo, Zhigang; Fang, Ying; Lieber, Charles M
2015-07-01
Seamless and minimally invasive three-dimensional interpenetration of electronics within artificial or natural structures could allow for continuous monitoring and manipulation of their properties. Flexible electronics provide a means for conforming electronics to non-planar surfaces, yet targeted delivery of flexible electronics to internal regions remains difficult. Here, we overcome this challenge by demonstrating the syringe injection (and subsequent unfolding) of sub-micrometre-thick, centimetre-scale macroporous mesh electronics through needles with a diameter as small as 100 μm. Our results show that electronic components can be injected into man-made and biological cavities, as well as dense gels and tissue, with >90% device yield. We demonstrate several applications of syringe-injectable electronics as a general approach for interpenetrating flexible electronics with three-dimensional structures, including (1) monitoring internal mechanical strains in polymer cavities, (2) tight integration and low chronic immunoreactivity with several distinct regions of the brain, and (3) in vivo multiplexed neural recording. Moreover, syringe injection enables the delivery of flexible electronics through a rigid shell, the delivery of large-volume flexible electronics that can fill internal cavities, and co-injection of electronics with other materials into host structures, opening up unique applications for flexible electronics.
Syringe-injectable electronics
NASA Astrophysics Data System (ADS)
Liu, Jia; Fu, Tian-Ming; Cheng, Zengguang; Hong, Guosong; Zhou, Tao; Jin, Lihua; Duvvuri, Madhavi; Jiang, Zhe; Kruskal, Peter; Xie, Chong; Suo, Zhigang; Fang, Ying; Lieber, Charles M.
2015-07-01
Seamless and minimally invasive three-dimensional interpenetration of electronics within artificial or natural structures could allow for continuous monitoring and manipulation of their properties. Flexible electronics provide a means for conforming electronics to non-planar surfaces, yet targeted delivery of flexible electronics to internal regions remains difficult. Here, we overcome this challenge by demonstrating the syringe injection (and subsequent unfolding) of sub-micrometre-thick, centimetre-scale macroporous mesh electronics through needles with a diameter as small as 100 μm. Our results show that electronic components can be injected into man-made and biological cavities, as well as dense gels and tissue, with >90% device yield. We demonstrate several applications of syringe-injectable electronics as a general approach for interpenetrating flexible electronics with three-dimensional structures, including (1) monitoring internal mechanical strains in polymer cavities, (2) tight integration and low chronic immunoreactivity with several distinct regions of the brain, and (3) in vivo multiplexed neural recording. Moreover, syringe injection enables the delivery of flexible electronics through a rigid shell, the delivery of large-volume flexible electronics that can fill internal cavities, and co-injection of electronics with other materials into host structures, opening up unique applications for flexible electronics.
Elaboration of a global strategy for containing microbial drug resistance.
Zabicki, W
2001-01-01
The World Health Organization is engaged in developing the Global Strategy for Containment of Antimicrobial Resistance. The preliminary document WHO/CDC/CSR/DRS/2000.I Draft has already been distributed, and remarks have been solicited.
The World Health Assembly Resolution of 1998 urged Member States to encourage the appropriate and cost-effective use of antimicrobials. Member States were requested to implement effective systems of microbial resistance surveillance and to monitor volumes and patterns of antimicrobial drug use.
The phenomenon of antimicrobial resistance is rising rapidly and causing growing international concern. Many countries have undertaken their own national plans to address the problem.
The overall aim of the strategy being developed is to find the most effective forms and to prevent the spread of antimicrobial resistance and resistant microbes. The strategy covers the following topics: patients and general community, prescribers, hospitals, veterinarians, manufacturers and drug dispensers, and international aspects.
The strategy is being developed on the basis of expert opinions, published reports, reviews of specific topics specially commissioned by various international and national bodies, and a large body of literature with a list of publications containing over 100 items.
Smale, Andrew; Tsouras, Theo
2017-01-01
We present a standardized test methodology and results for our evaluation of the Carefusion Alaris PC infusion pump, comprising the model 8015 PC Unit and the model 8100 Large Volume Pump (LVP) module. The evaluation consisted of basic suitability testing, internal component inspection, surface temperature measurement of selected internal components, and critical performance testing (infusion rate accuracy and occlusion alarm pressure) during conditions of typical hyperbaric oxygen (HBO₂) treatment in our facility's class A multiplace chamber. We have found that the pumps pose no enhanced risk as an ignition source, and that the pumps operate within manufacturer's specifications for flow rate and occlusion alarms at all stages of HBO₂ treatments, up to 4.0 ATA and pressurization and depressurization rates up to 180 kPa/minute. The pumps do not require purging with air or nitrogen and can be used unmodified, subject to the following conditions: pumps are undamaged, clean, fully charged, and absent from alcohol cleaning residue; pumps are powered from the internal NiMH battery only; maximum pressure exposure 4.0 ATA; maximum pressurization and depressurization rate of 180 kPa/minute; LVP modules locked in place with retaining screws. Copyright© Undersea and Hyperbaric Medical Society.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soultan, D; Murphy, J; James, C
2015-06-15
Purpose: To assess the accuracy of internal target volume (ITV) segmentation of lung tumors for treatment planning of simultaneous integrated boost (SIB) radiotherapy as seen in 4D PET/CT images, using a novel 3D-printed phantom. Methods: The insert mimics high PET tracer uptake in the core and 50% uptake in the periphery, by using a porous design at the periphery. A lung phantom with the insert was placed on a programmable moving platform. Seven breathing waveforms of ideal and patient-specific respiratory motion patterns were fed to the platform, and 4D PET/CT scans were acquired of each of them. CT images weremore » binned into 10 phases, and PET images were binned into 5 phases following the clinical protocol. Two scenarios were investigated for segmentation: a gate 30–70 window, and no gating. The radiation oncologist contoured the outer ITV of the porous insert with on CT images, while the internal void volume with 100% uptake was contoured on PET images for being indistinguishable from the outer volume in CT images. Segmented ITVs were compared to the expected volumes based on known target size and motion. Results: 3 ideal breathing patterns, 2 regular-breathing patient waveforms, and 2 irregular-breathing patient waveforms were used for this study. 18F-FDG was used as the PET tracer. The segmented ITVs from CT closely matched the expected motion for both no gating and gate 30–70 window, with disagreement of contoured ITV with respect to the expected volume not exceeding 13%. PET contours were seen to overestimate volumes in all the cases, up to more than 40%. Conclusion: 4DPET images of a novel 3D printed phantom designed to mimic different uptake values were obtained. 4DPET contours overestimated ITV volumes in all cases, while 4DCT contours matched expected ITV volume values. Investigation of the cause and effects of the discrepancies is undergoing.« less
The fifth international conference on Arabidopsis research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hangarter, R.; Scholl, R.; Davis, K.
This volume contains abstracts of oral and poster presentations made in conjunction with the Fifth International Conference on Arabidopsis Research held August 19--22, 1993 at the Ohio State University, Columbus, Ohio.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, Xianhui; Walker, Devin; Maiti, Debtanu
Cylindrical NiMg/Ce 0.6Zr 0.4O 2 pellet catalysts with two different sizes (large: radius = 1.59 mm; and small: radius = 0.75 mm) were produced by extrusion of powder catalysts. The small catalyst pellets had a higher specific surface area, pore volume, average pore size, radial crush strength, and resistance to breakage than the large ones. Tri-reforming tests with surrogate biogas were conducted at 3 bar and 882 °C, with the feed molar ratios of CH 4: CO 2: air fixed at 1.0: 0.7: 0.95 and the H 2O/CH 4 molar feed ratio (0.35 – 1.16) varied. The small catalyst pelletsmore » exhibited lower internal mass transfer resistance and higher coking resistance, compared to the large ones. CO 2 conversion decreased and H 2/CO molar ratio increased with the increase of H 2O/CH 4 molar feed ratio, which are consistent with the trends predicted by thermodynamic equilibrium calculations. Finally, the results indicate that the NiMg/Ce 0.6Zr 0.4O 2 catalyst pellets are promising for commercial scale applications.« less
Novel diamond cells for neutron diffraction using multi-carat CVD anvils
Boehler, R.; Molaison, J. J.; Haberl, B.
2017-08-17
Traditionally, neutron diffraction at high pressure has been severely limited in pressure because low neutron flux required large sample volumes and therefore large volume presses. At the high-flux Spallation Neutron Source at the Oak Ridge National Laboratory, we have developed in this paper new, large-volume diamond anvil cells for neutron diffraction. The main features of these cells are multi-carat, single crystal chemical vapor deposition diamonds, very large diffraction apertures, and gas membranes to accommodate pressure stability, especially upon cooling. A new cell has been tested for diffraction up to 40 GPa with an unprecedented sample volume of ~0.15 mm 3.more » High quality spectra were obtained in 1 h for crystalline Ni and in ~8 h for disordered glassy carbon. Finally, these new techniques will open the way for routine megabar neutron diffraction experiments.« less
Bray, F; Ferlay, J; Laversanne, M; Brewster, D H; Gombe Mbalawa, C; Kohler, B; Piñeros, M; Steliarova-Foucher, E; Swaminathan, R; Antoni, S; Soerjomataram, I; Forman, D
2015-11-01
Cancer Incidence in Five Continents (CI5), a longstanding collaboration between the International Agency for Research on Cancer and the International Association of Cancer Registries, serves as a unique source of cancer incidence data from high-quality population-based cancer registries around the world. The recent publication of Volume X comprises cancer incidence data from 290 registries covering 424 populations in 68 countries for the registration period 2003-2007. In this article, we assess the status of population-based cancer registries worldwide, describe the techniques used in CI5 to evaluate their quality and highlight the notable variation in the incidence rates of selected cancers contained within Volume X of CI5. We also discuss the Global Initiative for Cancer Registry Development as an international partnership that aims to reduce the disparities in availability of cancer incidence data for cancer control action, particularly in economically transitioning countries, already experiencing a rapid rise in the number of cancer patients annually. © 2015 UICC.
NASA Astrophysics Data System (ADS)
Kasyanenko, I. M.; Kramarenko, V. Yu.
2018-01-01
The effect of pigment volume concentration (PVC) on the film formation process and properties of coatings based on the water dispersion of an Acronal 290D styrene-acrylate copolymer and a pigment/filler system used for paint materials in construction was investigated. An analysis of the results obtained is performed within the framework of the concept of the critical PVC. It is shown that the initiation and development of internal stresses occurs the faster, the higher the PVC, but the position of the maximum or the inflection point of the internal stress-drying time curve complies with a universal value of the solid volume content in the compositions. It is found that the internal stresses and Young's modulus of coatings are characterized by an extreme concentration relation that, for the reduced elastic modulus, can be described by a system of equations based on the Halpin-Tsai equation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1992-01-01
Volume III, Minerals Yearbook -- International Review contains the latest available mineral data on more than 175 foreign countries and discusses the importance of minerals to the economies of these nations. Since the 1989 International Review, the volume has been presented as six reports. The report presents the Mineral Industries of Europe and Central Eurasia. The report incorporates location maps, industry structure tables, and an outlook section previously incorporated in the authors' Minerals Perspectives Series quinquennial regional books, which are being discontinued. This section of the Minerals Yearbook reviews the minerals industries of 45 countries: the 12 nations of themore » European Community (EC); 6 of the 7 nations of the European Free Trade Association (EFTA); Malta; the 11 Eastern European economies in transition (Albania, Bosnia and Hercegovina, Bulgaria, Croatia, Czechoslovakia, Hungary, Macedonia, Poland, Romania, Serbia and Montenegro, and Slovenia); and the countries of Central Eurasia (Armenia, Azerbaijan, Belarus, Estonia, Georgia, Kazakhstan, Kyrgystan, Latvia, Lithuania, Moldova, Russia, Tajikistan, Turkmenistan, Ukraine, and Uzbekistan).« less
Radiation from Large Gas Volumes and Heat Exchange in Steam Boiler Furnaces
DOE Office of Scientific and Technical Information (OSTI.GOV)
Makarov, A. N., E-mail: tgtu-kafedra-ese@mail.ru
2015-09-15
Radiation from large cylindrical gas volumes is studied as a means of simulating the flare in steam boiler furnaces. Calculations of heat exchange in a furnace by the zonal method and by simulation of the flare with cylindrical gas volumes are described. The latter method is more accurate and yields more reliable information on heat transfer processes taking place in furnaces.
Kumsar, Sukru; Kose, Osman; Aydemir, Huseyin; Halis, Fikret; Gokce, Ahmet; Adsan, Oztug; Akkaya, Zeynep Kahyaoglu
2016-01-01
This prospective analysis assessed the effect of histological prostatitis on lower urinary tract functions and sexual function. The patients were separated into two groups as histologically observed prostatitis (Group A) and no prostatitis (Group B) according to the biopsy outcomes. International prostate symptom score, international index of erectile function-5 scores, maximal and average flow rate, and residual urine volumes were compared statistically between groups. There was no significant difference (P>0.05) in baseline age (t=0.64), body mass index value (t=0.51), prostate volume (t=0.87), prostate-specific antigen levels (t=0.43), maximal (t=0.84) and average flow rate (t=0.59), and post-void residual urine volume (t=0.71). Mean international prostate symptom score in patients with prostatitis was numerically but not significantly higher than that in those without prostatitis (t=0.794, P=0.066). Mean international index of erectile function-5 score in the prostatitis group was significantly lower than that in those without prostatitis (t=1.854, P=0.013). Histological prostatitis notably affected sexual function of patients and may serve as a major risk factor for sexual dysfunction while having little effect on lower urinary tract symptoms.
Mars power system concept definition study. Volume 2: Appendices
NASA Technical Reports Server (NTRS)
Littman, Franklin D.
1994-01-01
This report documents the work performed by Rockwell International's Rocketdyne Division on NASA Contract No. NAS3-25808 (Task Order No. 16) entitled 'Mars Power System Definition Study'. This work was performed for NASA's Lewis Research Center (LeRC). The report is divided into two volumes as follows: Volume 1 - Study Results; and Volume 2 - Appendices. The results of the power system characterization studies, operations studies, and technology evaluations are summarized in Volume 1. The appendices include complete, standalone technology development plans for each candidate power system that was investigated.
First international E. coli genome meeting
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1992-12-31
This volume is a collection of abstracts of oral presentations and poster sessions of studies reported at the First International E. Coli Genome Meeting, held September 10-14, 1992 at the University of Wisconsin.
First international E. coli genome meeting
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1992-01-01
This volume is a collection of abstracts of oral presentations and poster sessions of studies reported at the First International E. Coli Genome Meeting, held September 10-14, 1992 at the University of Wisconsin.
The proceedings document presentations at the International Conference on Municipal Waste Combustion (MWC), held on April 11-14, 1989, in Hollywood, Florida. The objective of the Conference was to provide an effective international forum for the exchange and transfer of informati...
The proceedings document presentations at the International Conference on Municipal Waste Combustion (MWC), held on April 11-14, 1989, in Hollywood, Florida. The objective of the Conference was to provide an effective international forum for the exchange and transfer of informati...
The proceedings document presentations at the International Conference on Municipal Waste Combustion (MWC), held on April 11-14, 1989, in Hollywood, Florida. The objective of the Conference was to provide an effective international forum for the exchange and transfer of informati...
International Union for Conservation of Nature Bulletin (IUCN), Volume 4 Number 5.
ERIC Educational Resources Information Center
International Union for Conservation of Nature and Natural Resources, Morges, (Switzerland).
Compiled in this newsletter are activities, viewpoints, reports, book reviews, and conference proceedings emanating from the International Union for Conservation of Nature and Natural Resources (IUCN). Principle items deal with viewpoints of politics and conservation and the International Workshop on Environmental Studies in Higher Education and…
Proceedings of the third ISHS international symposium of plant genetic resources volume 1
USDA-ARS?s Scientific Manuscript database
The Third International ISHS Symposium on plant genetic resources occurred as Symposium 12 of the International Horticulture Congress in Lisbon, in August 2010. This symposium lasted4 days and emphasized new tools in plant genetic resource management. Six speakers gave invited presentations, and 30 ...
Proceedings of the third ISHS international symposium on plant genetic resources volume 2
USDA-ARS?s Scientific Manuscript database
The Third International ISHS Symposium on plant genetic resources occurred as Symposium 12 of the International Horticulture Congress in Lisbon, in August 2010. This symposium lasted4 days and emphasized new tools in plant genetic resource management. Six speakers gave invited presentations, and 30 ...
INTERNATIONAL STUDY OF ACHIEVEMENT IN MATHEMATICS, A COMPARISON OF TWELVE COUNTRIES, VOLUME I.
ERIC Educational Resources Information Center
HUSEN, TORSTEN; AND OTHERS
THIS REPORT OF AN INTERNATIONAL RESEARCH ALLIANCE OF TWELVE COUNTRIES EXPLAINS THE ESTABLISHMENT OF PROCEDURES OF RESEARCH AND QUANTITATIVE ASSESSMENT FOR THE COMPARATIVE STUDY OF EDUCATION THROUGHOUT THE WORLD. RESEARCH INSTITUTES FROM TWELVE COUNTRIES ORGANIZED THE COUNCIL OF THE INTERNATIONAL PROJECT FOR THE EVALUATION OF EDUCATIONAL…
The proceedings document presentations at the International Conference on Municipal Waste Combustion (MWC), held on April 11-l4, 1989, in Hollywood, Florida. The objective of the Conference was to provide an effective international forum for tile exchange and transfer of informat...
The proceedings document presentations at the International Conference on Municipal Waste Combustion (MWC), held on April 11-l4, 1989, in Hollywood, Florida. The objective of the Conference was to provide an effective international forum for tile exchange and transfer of informat...
The proceedings document presentations at the International Conference on Municipal Waste Combustion (MWC), held on April 11-l4, 1989, in Hollywood, Florida. The objective of the Conference was to provide an effective international forum for tile exchange and transfer of informat...
The proceedings document presentations at the International Conference on Municipal Waste Combustion (MWC), held on April 11-l4, 1989, in Hollywood, Florida. The objective of the Conference was to provide an effective international forum for tile exchange and transfer of informat...
Leow, Jeffrey J; Reese, Stephen; Trinh, Quoc-Dien; Bellmunt, Joaquim; Chung, Benjamin I; Kibel, Adam S; Chang, Steven L
2015-05-01
To evaluate the relationship between surgeon volume of radical cystectomy (RC) and postoperative morbidity, and to assess the economic burden of bladder cancer in the USA. We captured all patients who underwent RC (International Classification of Diseases, ninth revision, code 57.71) between 2003 and 2010, using a nationwide hospital discharge database. Patient, hospital and surgical characteristics were evaluated. The annual volume of RCs performed by the surgeons was divided into quintiles. Multivariable regression models were developed, adjusting for clustering and survey weighting, to evaluate the outcomes, including 90-day major complications (Clavien grade III-V) and direct patient costs. We adjusted for clustering and weighting to achieve a nationally representative analysis. The weighted cohort included 49,792 patients who underwent RC, with an overall 90-day major complication rate of 16.2%. Compared with surgeons performing one RC annually, surgeons performing ≥7 RCs each year had 45% lower odds of major complications (odds ratio [OR] 0.55; P < 0.001) and lower costs by $1690 (P = 0.02). Results were consistent when we analysed surgeon volume as a continuous variable and when we examined the surgeons with the highest volumes (≥28 cases annually), which showed markedly lower odds of major complications compared with the surgeons with the lowest volumes (OR 0.45, 95% CI 0.31-0.67; P < 0.001). Compared with patients who did not have any complications, those who had a major complication were associated with significantly higher 90-day median direct hospital costs ($43,965 vs $24,341; P < 0.001). We showed that there was an inverse relationship between surgeon volume and the development of postoperative 90-day major complication rates as well as direct hospital costs. Centralisation of RC to surgeons with higher volumes may reduce the development of postoperative major complications, thereby decreasing the burden of bladder cancer on the healthcare system. © 2014 The Authors. BJU International © 2014 BJU International.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cai Jing; Read, Paul W.; Baisden, Joseph M.
Purpose: To evaluate the error in four-dimensional computed tomography (4D-CT) maximal intensity projection (MIP)-based lung tumor internal target volume determination using a simulation method based on dynamic magnetic resonance imaging (dMRI). Methods and Materials: Eight healthy volunteers and six lung tumor patients underwent a 5-min MRI scan in the sagittal plane to acquire dynamic images of lung motion. A MATLAB program was written to generate re-sorted dMRI using 4D-CT acquisition methods (RedCAM) by segmenting and rebinning the MRI scans. The maximal intensity projection images were generated from RedCAM and dMRI, and the errors in the MIP-based internal target area (ITA)more » from RedCAM ({epsilon}), compared with those from dMRI, were determined and correlated with the subjects' respiratory variability ({nu}). Results: Maximal intensity projection-based ITAs from RedCAM were comparatively smaller than those from dMRI in both phantom studies ({epsilon} = -21.64% {+-} 8.23%) and lung tumor patient studies ({epsilon} = -20.31% {+-} 11.36%). The errors in MIP-based ITA from RedCAM correlated linearly ({epsilon} = -5.13{nu} - 6.71, r{sup 2} = 0.76) with the subjects' respiratory variability. Conclusions: Because of the low temporal resolution and retrospective re-sorting, 4D-CT might not accurately depict the excursion of a moving tumor. Using a 4D-CT MIP image to define the internal target volume might therefore cause underdosing and an increased risk of subsequent treatment failure. Patient-specific respiratory variability might also be a useful predictor of the 4D-CT-induced error in MIP-based internal target volume determination.« less
NASA Astrophysics Data System (ADS)
Lu, Haibao; Wang, Xiaodong; Yao, Yongtao; Qing Fu, Yong
2018-06-01
Phenomenological models based on frozen volume parameters could well predict shape recovery behavior of shape memory polymers (SMPs), but the physical meaning of using the frozen volume parameters to describe thermomechanical properties has not been well-established. In this study, the fundamental working mechanisms of the shape memory effect (SME) in amorphous SMPs, whose temperature-dependent viscoelastic behavior follows the Eyring equation, have been established with the considerations of both internal stress and its resulted frozen volume. The stress-strain constitutive relation was initially modeled to quantitatively describe effects of internal stresses at the macromolecular scale based on the transient network theory. A phenomenological ‘frozen volume’ model was then established to characterize the macromolecule structure and SME of amorphous SMPs based on a two-site stress-relaxation model. Effects of the internal stress, frozen volume and strain rate on shape memory behavior and thermomechanical properties of the SMP were investigated. Finally, the simulation results were compared with the experimental results reported in the literature, and good agreements between the theoretical and experimental results were achieved. The novelty and key differences of our newly proposed model with respect to the previous reports are (1). The ‘frozen volume’ in our study is caused by the internal stress and governed by the two-site model theory, thus has a good physical meaning. (2). The model can be applied to characterize and predict both the thermal and thermomechanical behaviors of SMPs based on the constitutive relationship with internal stress parameters. It is expected to provide a power tool to investigate the thermomechanical behavior of the SMPs, of which both the macromolecular structure characteristics and SME could be predicted using this ‘frozen volume’ model.
Cai, Jing; Read, Paul W; Baisden, Joseph M; Larner, James M; Benedict, Stanley H; Sheng, Ke
2007-11-01
To evaluate the error in four-dimensional computed tomography (4D-CT) maximal intensity projection (MIP)-based lung tumor internal target volume determination using a simulation method based on dynamic magnetic resonance imaging (dMRI). Eight healthy volunteers and six lung tumor patients underwent a 5-min MRI scan in the sagittal plane to acquire dynamic images of lung motion. A MATLAB program was written to generate re-sorted dMRI using 4D-CT acquisition methods (RedCAM) by segmenting and rebinning the MRI scans. The maximal intensity projection images were generated from RedCAM and dMRI, and the errors in the MIP-based internal target area (ITA) from RedCAM (epsilon), compared with those from dMRI, were determined and correlated with the subjects' respiratory variability (nu). Maximal intensity projection-based ITAs from RedCAM were comparatively smaller than those from dMRI in both phantom studies (epsilon = -21.64% +/- 8.23%) and lung tumor patient studies (epsilon = -20.31% +/- 11.36%). The errors in MIP-based ITA from RedCAM correlated linearly (epsilon = -5.13nu - 6.71, r(2) = 0.76) with the subjects' respiratory variability. Because of the low temporal resolution and retrospective re-sorting, 4D-CT might not accurately depict the excursion of a moving tumor. Using a 4D-CT MIP image to define the internal target volume might therefore cause underdosing and an increased risk of subsequent treatment failure. Patient-specific respiratory variability might also be a useful predictor of the 4D-CT-induced error in MIP-based internal target volume determination.
Unmanned Vehicle Material Flammability Test
NASA Technical Reports Server (NTRS)
Urban, David; Ruff, Gary A.; Fernandez-Pello, A. Carlos; T’ien, James S.; Torero, Jose L.; Cowlard, Adam; Rouvreau, Sebastian; Minster, Olivier; Toth, Balazs; Legros, Guillaume;
2013-01-01
Microgravity combustion phenomena have been an active area of research for the past 3 decades however, there have been very few experiments directly studying spacecraft fire safety under low-gravity conditions. Furthermore, none of these experiments have studied sample and environment sizes typical of those expected in a spacecraft fire. All previous experiments have been limited to samples of the order of 10 cm in length and width or smaller. Terrestrial fire safety standards for all other habitable volumes on earth, e.g. mines, buildings, airplanes, ships, etc., are based upon testing conducted with full-scale fires. Given the large differences between fire behavior in normal and reduced gravity, this lack of an experimental data base at relevant length scales forces spacecraft designers to base their designs using 1-g understanding. To address this question a large scale spacecraft fire experiment has been proposed by an international team of investigators. This poster presents the objectives, status and concept of this collaborative international project to examine spacecraft material flammability at realistic scales. The concept behind this project is to utilize an unmanned spacecraft such as Orbital Cygnus vehicle after it has completed its delivery of cargo to the ISS and it has begun its return journey to earth. This experiment will consist of a flame spread test involving a meter scale sample ignited in the pressurized volume of the spacecraft and allowed to burn to completion while measurements are made. A computer modeling effort will complement the experimental effort. Although the experiment will need to meet rigorous safety requirements to ensure the carrier vehicle does not sustain damage, the absence of a crew removes the need for strict containment of combustion products. This will facilitate the examination of fire behavior on a scale that is relevant to spacecraft fire safety and will provide unique data for fire model validation. This will be the first opportunity to examine microgravity flame behavior at scales approximating a spacecraft fire.
Moore, Jeremy K; Chen, Junjie; Pan, Hua; Gaut, Joseph P; Jain, Sanjay; Wickline, Samuel A
2018-06-01
To design a fluorine MRI/MR spectroscopy approach to quantify renal vascular damage after ischemia-reperfusion injury, and the therapeutic response to antithrombin nanoparticles (NPs) to protect kidney function. A total of 53 rats underwent 45 min of bilateral renal artery occlusion and were treated at reperfusion with either plain perfluorocarbon NPs or NPs functionalized with a direct thrombin inhibitor (PPACK:phenyalanine-proline-arginine-chloromethylketone). Three hours after reperfusion, kidneys underwent ex vivo fluorine MRI/MR spectroscopy at 4.7 T to quantify the extent and volume of trapped NPs, as an index of vascular damage and ischemia-reperfusion injury. Microscopic evaluation of structural damage and NP trapping in non-reperfused renal segments was performed. Serum creatinine was quantified serially over 7 days. The damaged renal cortico-medullary junction trapped a significant volume of NPs (P = 0.04), which correlated linearly (r = 0.64) with the severity of kidney injury 3 h after reperfusion. Despite global large vessel reperfusion, non-reperfusion in medullary peritubular capillaries was confirmed by MRI and microscopy, indicative of continuing hypoxia due to vascular compromise. Treatment of animals with PPACK NPs after acute kidney injury did not accelerate kidney functional recovery. Quantification of ischemia-reperfusion injury after acute kidney injury with fluorine MRI/MR spectroscopy of perfluorocarbon NPs objectively depicts the extent and severity of vascular injury and its linear relationship to renal dysfunction. The lack of kidney function improvement after early posttreatment thrombin inhibition confirms the rapid onset of ischemia-reperfusion injury as a consequence of vascular damage and non-reperfusion. The prolongation of medullary ischemia renders cortico-medullary tubular structures susceptible to continued necrosis despite restoration of large vessel flow, which suggests limitations to acute interventions after acute kidney injury, designed to interdict renal tubular damage. Magn Reson Med 79:3144-3153, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Coupled Orbital and Thermal Evolution of Ganymede
NASA Astrophysics Data System (ADS)
Showman, Adam P.; Stevenson, David J.; Malhotra, Renu
1997-10-01
We explore the hypothesis that passage through an eccentricity-pumping resonance could lead to the resurfacing of Ganymede. To do so, we couple R. Malhotra's (1991,Icarus94,399-412) orbital model for the tidal evolution of the Laplace resonance to an internal model of Ganymede. Our model explores the conditions under which Ganymede can undergo global thermal runaway, assuming that theQ/kof Ganymede is strongly dependent on internal temperature. (HereQis the tidal dissipation function andkis the second-degree Love number.) We allow the system to pass through the ω1/ω2≈ 2 or ω1/ω2≈ 1/2 resonance, where ω1≡ 2n2-n1, ω2≡ 2n3-n2, andn1,n2, andn3are the mean motions of Io, Europa, and Ganymede. If Ganymede's initial internal temperature is either “too hot” or “too cold,” no runaway occurs, while for intermediate temperatures (∼200 K in the upper mantle), conditions are “just right,” and runaway occurs. The range of mantle temperatures that allows runaway depends on the model for tidalQ; we use the Maxwell model, which tiesQto the creep viscosity of ice. Runaways can induce up to ∼50-100 K warming and formation of a large internal ocean; they occur over a 107to 108-year period. Assuming carbonaceous chondritic abundances of radionuclides in Ganymede's rocky portion, however, we find that the interior cannot cool to the initial temperatures needed to allow large runaways. If our model is correct, large runaways cannot occur, although small runaways are still possible. Different formulations of tidalQor convective cooling may allow large runaways. Large runaways are also possible if radionuclides are substantially depleted, although this is unlikely. We next consider the consequences of a large runaway, assuming it can occur. Ganymede can undergo 0.5% thermal expansion (by volume) during the largest thermal runaways. Melting of the ice mantle provides up to 2% expansion despite the fact that contraction produced by melting ice I offsets expansion produced by melting high-pressure ice phases. Solid-solid phase transitions cause negligible satellite expansion. Lithospheric stresses caused by expansion of 2% over 107to 108years are ∼102bars at the surface, and drop to a few bars at several kilometers depth. Such stresses could cause cracking to depths of several kilometers. The cracking and near-surface production of warm or partially molten ice make resurfacing a plausible outcome of a large thermal runaway. The tidal heating events proposed here may also be relevant for generation of Ganymede's modern-day magnetic field.
Luethy, D; Stefanovski, D; Salber, R; Sweeney, R W
2017-11-01
Calculation of desired whole blood transfusion volume relies on an estimate of an animal's circulating blood volume, generally accepted to be 0.08 L/kg or 8% of the animal's body weight in kilograms. To use packed cell volume before and after whole blood transfusion to evaluate the accuracy of a commonly used equation to predict packed cell volume after transfusion in small ruminants and South American camelids; to determine the nature and frequency of adverse transfusion reactions in small ruminants and camelids after whole blood transfusion. Fifty-eight small ruminants and 22 alpacas that received whole blood transfusions for anemia. Retrospective case series; medical record review for small ruminants and camelids that received whole blood transfusions during hospitalization. Mean volume of distribution of blood as a fraction of body weight in sheep (0.075 L/kg, 7.5% BW) and goats (0.076 L/kg, 7.6% BW) differed significantly (P < 0.01) from alpacas (0.103 L/kg, 10.3% BW). Mild transfusion reactions were noted in 16% of transfusions. The generally accepted value of 8% for circulating blood volume (volume of distribution of blood) is adequate for calculation of transfusion volumes; however, use of the species-specific circulating blood volume can improve calculation of transfusion volume to predict and achieve desired packed cell volume. The incidence of transfusion reactions in small ruminants and camelids is low. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gangsaas, Anne, E-mail: a.gangsaas@erasmusmc.nl; Astreinidou, Eleftheria; Quint, Sandra
2013-10-01
Purpose: To investigate interfraction setup variations of the primary tumor, elective nodes, and vertebrae in laryngeal cancer patients and to validate protocols for cone beam computed tomography (CBCT)-guided correction. Methods and Materials: For 30 patients, CBCT-measured displacements in fractionated treatments were used to investigate population setup errors and to simulate residual setup errors for the no action level (NAL) offline protocol, the extended NAL (eNAL) protocol, and daily CBCT acquisition with online analysis and repositioning. Results: Without corrections, 12 of 26 patients treated with radical radiation therapy would have experienced a gradual change (time trend) in primary tumor setup ≥4more » mm in the craniocaudal (CC) direction during the fractionated treatment (11/12 in caudal direction, maximum 11 mm). Due to these trends, correction of primary tumor displacements with NAL resulted in large residual CC errors (required margin 6.7 mm). With the weekly correction vector adjustments in eNAL, the trends could be largely compensated (CC margin 3.5 mm). Correlation between movements of the primary and nodal clinical target volumes (CTVs) in the CC direction was poor (r{sup 2}=0.15). Therefore, even with online setup corrections of the primary CTV, the required CC margin for the nodal CTV was as large as 6.8 mm. Also for the vertebrae, large time trends were observed for some patients. Because of poor CC correlation (r{sup 2}=0.19) between displacements of the primary CTV and the vertebrae, even with daily online repositioning of the vertebrae, the required CC margin around the primary CTV was 6.9 mm. Conclusions: Laryngeal cancer patients showed substantial interfraction setup variations, including large time trends, and poor CC correlation between primary tumor displacements and motion of the nodes and vertebrae (internal tumor motion). These trends and nonrigid anatomy variations have to be considered in the choice of setup verification protocol and planning target volume margins. eNAL could largely compensate time trends with minor prolongation of fraction time.« less
Environmentalism and natural aggregate mining
Drew, L.J.; Langer, W.H.; Sachs, J.S.
2002-01-01
Sustaining a developed economy and expanding a developing one require the use of large volumes of natural aggregate. Almost all human activity (commercial, recreational, or leisure) is transacted in or on facilities constructed from natural aggregate. In our urban and suburban worlds, we are almost totally dependent on supplies of water collected behind dams and transported through aqueducts made from concrete. Natural aggregate is essential to the facilities that produce energy-hydroelectric dams and coal-fired powerplants. Ironically, the utility created for mankind by the use of natural aggregate is rarely compared favorably with the environmental impacts of mining it. Instead, the empty quarries and pits are seen as large negative environmental consequences. At the root of this disassociation is the philosophy of environmentalism, which flavors our perceptions of the excavation, processing, and distribution of natural aggregate. The two end-member ideas in this philosophy are ecocentrism and anthropocentrism. Ecocentrism takes the position that the natural world is a organism whose arteries are the rivers-their flow must not be altered. The soil is another vital organ and must not be covered with concrete and asphalt. The motto of the ecocentrist is "man must live more lightly on the land." The anthropocentrist wants clean water and air and an uncluttered landscape for human use. Mining is allowed and even encouraged, but dust and noise from quarry and pit operations must be minimized. The large volume of truck traffic is viewed as a real menace to human life and should be regulated and isolated. The environmental problems that the producers of natural aggregate (crushed stone and sand and gravel) face today are mostly difficult social and political concerns associated with the large holes dug in the ground and the large volume of heavy truck traffic associated with quarry and pit operations. These concerns have increased in recent years as society's demand for living space has encroached on the sites of production; in other words, the act of production has engendered condemnation. Many other environmental problems that are associated with dust and noise and blasting from quarry and pit operations have been reduced through the efficient use of technology. Recycling concrete in buildings, bridges, and roads and asphaltic pavements will ultimately reduce the demand for virgin natural aggregate. The impact created by the large holes in the ground required for the mining of natural aggregate can be greatly reduced by planning their reclamation before mining begins. ?? 2002 International Association for Mathematical Geology.
Müller, B. R.; Cooper, R. C.; Lange, A.; ...
2017-11-01
In order to investigate their microcracking behaviour, the microstructures of several β-eucryptite ceramics, obtained from glass precursor and cerammed to yield different grain sizes and microcrack densities, were characterized by laboratory and synchrotron x-ray refraction and tomography. Here, results were compared with those obtained from scanning electron microscopy (SEM). In SEM images, the characterized materials appeared fully dense but computed tomography showed the presence of pore clusters. Uniaxial tensile testing was performed on specimens while strain maps were recorded and analyzed by Digital Image Correlation (DIC). X-ray refraction techniques were applied on specimens before and after tensile testing to measuremore » the amount of the internal specific surface (i.e., area per unit volume). X-ray refraction revealed that (a) the small grain size (SGS) material contained a large specific surface, originating from the grain boundaries and the interfaces of TiO 2 precipitates; (b) the medium (MGS) and large grain size (LGS) materials possessed higher amounts of specific surface compared to SGS material due to microcracks, which decreased after tensile loading; (c) the precursor glass had negligible internal surface. The unexpected decrease in the internal surface of MGS and LGS after tensile testing is explained by the presence of compressive regions in the DIC strain maps and further by theoretical arguments. It is suggested that while some microcracks merge via propagation, more close mechanically, thereby explaining the observed X-ray refraction results. Lastly, the mechanisms proposed would allow the development of a strain hardening route in ceramics.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Müller, B. R.; Cooper, R. C.; Lange, A.
In order to investigate their microcracking behaviour, the microstructures of several β-eucryptite ceramics, obtained from glass precursor and cerammed to yield different grain sizes and microcrack densities, were characterized by laboratory and synchrotron x-ray refraction and tomography. Here, results were compared with those obtained from scanning electron microscopy (SEM). In SEM images, the characterized materials appeared fully dense but computed tomography showed the presence of pore clusters. Uniaxial tensile testing was performed on specimens while strain maps were recorded and analyzed by Digital Image Correlation (DIC). X-ray refraction techniques were applied on specimens before and after tensile testing to measuremore » the amount of the internal specific surface (i.e., area per unit volume). X-ray refraction revealed that (a) the small grain size (SGS) material contained a large specific surface, originating from the grain boundaries and the interfaces of TiO 2 precipitates; (b) the medium (MGS) and large grain size (LGS) materials possessed higher amounts of specific surface compared to SGS material due to microcracks, which decreased after tensile loading; (c) the precursor glass had negligible internal surface. The unexpected decrease in the internal surface of MGS and LGS after tensile testing is explained by the presence of compressive regions in the DIC strain maps and further by theoretical arguments. It is suggested that while some microcracks merge via propagation, more close mechanically, thereby explaining the observed X-ray refraction results. Lastly, the mechanisms proposed would allow the development of a strain hardening route in ceramics.« less
Big Data challenges and solutions in building the Global Earth Observation System of Systems (GEOSS)
NASA Astrophysics Data System (ADS)
Mazzetti, Paolo; Nativi, Stefano; Santoro, Mattia; Boldrini, Enrico
2014-05-01
The Group on Earth Observation (GEO) is a voluntary partnership of governments and international organizations launched in response to calls for action by the 2002 World Summit on Sustainable Development and by the G8 (Group of Eight) leading industrialized countries. These high-level meetings recognized that international collaboration is essential for exploiting the growing potential of Earth observations to support decision making in an increasingly complex and environmentally stressed world. To this aim is constructing the Global Earth Observation System of Systems (GEOSS) on the basis of a 10-Year Implementation Plan for the period 2005 to 2015 when it will become operational. As a large-scale integrated system handling large datasets as those provided by Earth Observation, GEOSS needs to face several challenges related to big data handling and big data infrastructures management. Referring to the traditional multiple Vs characteristics of Big Data (volume, variety, velocity, veracity and visualization) it is evident how most of them can be found in data handled by GEOSS. In particular, concerning Volume, Earth Observation already generates a large amount of data which can be estimated in the range of Petabytes (1015 bytes), with Exabytes (1018) already targeted. Moreover, the challenge is related not only to the data size, but also to the large amount of datasets (not necessarily having a big size) that systems need to manage. Variety is the other main challenge since datasets coming from different sensors, processed for different use-cases are published with highly heterogeneous metadata and data models, through different service interfaces. Innovative multidisciplinary applications need to access and use those datasets in a harmonized way. Moreover Earth Observation data are growing in size and variety at an exceptionally fast rate and new technologies and applications, including crowdsourcing, will even increase data volume and variety in the next future. The current implementation of GEOSS already addresses several big data challenges. In particular, the brokered architecture adopted in the GEOSS Common Infrastructure with the deployment of the GEO DAB (Discovery and Access Broker) allows to connect more than 20 big EO infrastructures while keeping them autonomous as required by their own mandate and governance. They make more than 60 million of unique resources discoverable and accessible through the GEO Portal. Through the GEO DAB, users are able to seamlessly discover resources provided by different infrastructures, and access them in a harmonized way, collecting datasets from different sources on a Common Environment (same coordinate reference system, spatial subset, format, etc.). Through the GEONETCast system, GEOSS is also providing a solution related to the Velocity challenge, for delivering EO resources to developing countries with low bandwidth connections. Several researches addressing other Big data Vs challenges in GEOSS are on-going, including quality representation for Veracity (as in the FP7 GeoViQua project), brokering big data analytics platforms for Velocity, and support of other EO resources for Variety (such as modelling resources in the Model Web).
Yield table for hardwood bark residue
Jeffery L. Wartluft
1974-01-01
Bark residue weights are tabulated for eight species of hardwood sawlogs according to log volume by the Doyle, International 1/4-inch, and Scribner decimal C log rules. Factors are provided for converting from weight in pounds to volume in cubic yards.
COAL CONVERSION CONTROL TECHNOLOGY. VOLUME I. ENVIRONMENTAL REGULATIONS; LIQUID EFFLUENTS
This volume is the product of an information-gathering effort relating to coal conversion process streams. Available and developing control technology has been evaluated in view of the requirements of present and proposed federal, state, regional, and international environmental ...
COAL CONVERSION CONTROL TECHNOLOGY. VOLUME II. GASEOUS EMISSIONS; SOLID WASTES
This volume is the product of an information-gathering effort relating to coal conversion process streams. Available and developing control technology has been evaluated in view of the requirements of present and proposed federal, state, regional, and international environmental ...
In vivo organ mass of Korean adults obtained from whole-body magnetic resonance data.
Park, S; Lee, J K; Kim, J I; Lee, Y J; Lim, Y K; Kim, C S; Lee, C
2006-01-01
In vivo organ mass of the Korean adult, male and female were presented for the purpose of radiation protection. A total of 121 healthy volunteers (66 males and 55 females), whose body dimensions were close to that of average Korean adults, were recruited for this study. Whole-body magnetic resonance (MR) images were obtained, and contours of 15 organs (brain, eye, gall bladder, heart, kidney, liver, lung, pancreas, stomach, spleen, testes, thymus, thyroid, urinary bladder and uterus) and 9 bones (femur, tibia + fibula, humerus, radius + ulna, pelvis, cervical spine, thoracic and lumber spine, skull and clavicle) were segmented for organ volume rendering by anatomists using commercial software. Organ and bone masses were calculated by multiplying the Asian reference densities of the corresponding organs and bones by the measured volumes. The resulting organ and bone masses were compared with those of the International Commission of Radiological Protection (ICRP) and the Asian reference data. Significantly large standard deviation was shown in the moving organs of the respiratory and circulatory systems and in the alimentary and urogenital organs that are variable in volume in a single person. Gall bladder and pancreas showed unique Korean organ masses compared with those of ICRP and the Asian reference adults. Different from anatomical data based on autopsy, the in vivo volume and mass in this study can more exactly describe the organ volume of a living human subject for radiation protection. A larger sample size would be required for obtaining statistically more reliable results. It is also needed to establish the reference organ mass of younger age groups for which it is difficult to recruit volunteers and to immobilise the subjects for long-time MR scanning. At present, the data from this study will contribute to the establishment of a Korean reference database.
Target coverage in image-guided stereotactic body radiotherapy of liver tumors.
Wunderink, Wouter; Méndez Romero, Alejandra; Vásquez Osorio, Eliana M; de Boer, Hans C J; Brandwijk, René P; Levendag, Peter C; Heijmen, Ben J M
2007-05-01
To determine the effect of image-guided procedures (with computed tomography [CT] and electronic portal images before each treatment fraction) on target coverage in stereotactic body radiotherapy for liver patients using a stereotactic body frame (SBF) and abdominal compression. CT guidance was used to correct for day-to-day variations in the tumor's mean position in the SBF. By retrospectively evaluating 57 treatment sessions, tumor coverage, as obtained with the clinically applied CT-guided protocol, was compared with that of alternative procedures. The internal target volume-plus (ITV(+)) was introduced to explicitly include uncertainties in tumor delineations resulting from CT-imaging artifacts caused by residual respiratory motion. Tumor coverage was defined as the volume overlap of the ITV(+), derived from a tumor delineated in a treatment CT scan, and the planning target volume. Patient stability in the SBF, after acquisition of the treatment CT scan, was evaluated by measuring the displacement of the bony anatomy in the electronic portal images relative to CT. Application of our clinical protocol (with setup corrections following from manual measurements of the distances between the contours of the planning target volume and the daily clinical target volume in three orthogonal planes, multiple two-dimensional) increased the frequency of nearly full (> or = 99%) ITV(+) coverage to 77% compared with 63% without setup correction. An automated three-dimensional method further improved the frequency to 96%. Patient displacements in the SBF were generally small (< or = 2 mm, 1 standard deviation), but large craniocaudal displacements (maximal 7.2 mm) were occasionally observed. Daily, CT-assisted patient setup may substantially improve tumor coverage, especially with the automated three-dimensional procedure. In the present treatment design, patient stability in the SBF should be verified with portal imaging.